WorldWideScience

Sample records for performing monitoring diagnostics

  1. Development of a computerized system for performance monitoring and diagnostics in nuclear power plants

    International Nuclear Information System (INIS)

    Chou, G.H.; Chao, H.J.

    1995-01-01

    An on-line computerized system for thermal performance monitoring and diagnostics has been developed at the Institute of Nuclear Energy Research (INER). It was the product of the ChinShan plant performance Monitoring, Analysis and Diagnostics Expert System (CS-MADES) project sponsored by Taiwan Power Company (TPC). The system can carry out turbine performance monitoring and analysis during normal operation, and yield diagnostic results of component degradation after finding out the missing generation problems. Three subsystems were generated to support the whole system framework. They are Test Data Processing Subsystem (TDPS), On-line Monitoring and Analysis Subsystem (OMAS), and Thermal Performance Diagnostics Expert System (TPDES). Some visible benefits have been gained so far through the prototype system installed at the Chinshan nuclear power station

  2. An Integrated Architecture for On-Board Aircraft Engine Performance Trend Monitoring and Gas Path Fault Diagnostics

    Science.gov (United States)

    Simon, Donald L.

    2010-01-01

    Aircraft engine performance trend monitoring and gas path fault diagnostics are closely related technologies that assist operators in managing the health of their gas turbine engine assets. Trend monitoring is the process of monitoring the gradual performance change that an aircraft engine will naturally incur over time due to turbomachinery deterioration, while gas path diagnostics is the process of detecting and isolating the occurrence of any faults impacting engine flow-path performance. Today, performance trend monitoring and gas path fault diagnostic functions are performed by a combination of on-board and off-board strategies. On-board engine control computers contain logic that monitors for anomalous engine operation in real-time. Off-board ground stations are used to conduct fleet-wide engine trend monitoring and fault diagnostics based on data collected from each engine each flight. Continuing advances in avionics are enabling the migration of portions of the ground-based functionality on-board, giving rise to more sophisticated on-board engine health management capabilities. This paper reviews the conventional engine performance trend monitoring and gas path fault diagnostic architecture commonly applied today, and presents a proposed enhanced on-board architecture for future applications. The enhanced architecture gains real-time access to an expanded quantity of engine parameters, and provides advanced on-board model-based estimation capabilities. The benefits of the enhanced architecture include the real-time continuous monitoring of engine health, the early diagnosis of fault conditions, and the estimation of unmeasured engine performance parameters. A future vision to advance the enhanced architecture is also presented and discussed

  3. Comparison of 3MP medical-grade to 1MP office grade LCD monitors in mammographic diagnostic and perceptual performance

    International Nuclear Information System (INIS)

    Ong, Aaron; Tan, Shu.; Gledhill, Samuel; Hennessy, Oliver; Lui, Belinda; Lee, Alan; Lemish, Wayne; Styles, Colin; Pun, Emma; Padmanabhan, Meenakshi; Pitman, Alexander G.; Tauro, Paul; Waugh, Paul

    2011-01-01

    Full text: Picture archiving and communication systems images designed to be viewed on high-resolution medical-grade monitors are routinely viewed on office-grade monitors on the wards or at home. This study aimed to determine whether a statistically significant difference in diagnostic (cancer detection) and perceptual (microcalcification detection) performance exists between 3MP grade and 1MP office-grade monitors. 3MP Dome medical-grade liquid crystal display (LCD) monitors (Planar, Beaverton, OR, USA) were compared to 1MP Dell office-grade LCD monitors (Dell Inc, Round Rock, TX, USA). Eight radiologists (reader experi ence 8-30 years) read the same set of 100 mammograms (23/100 with proven cancers and 52/100 with microcalcifications) presented in random order on three occasions separated by two time intervals of 12 weeks. Reads 1 and 3 utilised 3MP monitors and formed the baseline read. Read 2 utilised 1MP monitors and constituted the experimental read. Reading conditions were standardised. Readers were aware of which monitors they were using. Mul tivariate logistic regression analysis (to account for reader variability and monitor impact) was performed to assess for statistical significance. At a = 5%, confidence intervals analysis comparing the measured parameters between 1MP to 3MP monitors demonstrated no statistically significant difference in diagnostic and perceptual performance for the reader group. In cancer detection (the diagnostic task), reader accuracy remained high irrespective of monitor type. Regression analysis comparing performance with 1MP against 3MP monitors found P values of 0.693 and 0.324 for diagnostic and perceptual performance, respectively. There were no statistically and clinically significant differences between 3MP and 1MP monitors in mammographic diagnostic and perceptual performance. Comparable performance may be due to compensatory behav iour by readers.

  4. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  5. Performance diagnostic system for emergency diesel generators

    International Nuclear Information System (INIS)

    Logan, K.P.

    1991-01-01

    Diesel generators are commonly used for emergency backup power at nuclear stations. Emergency diesel generators (EDGs) are subject to both start-up and operating failures, due to infrequent and fast-start use. EDG reliability can be critical to plant safety, particularly when station blackout occurs. This paper describes an expert diagnostic system designed to consistently evaluate the operating performance of diesel generators. The prototype system is comprised of a suite of sensor monitoring, cylinder combustion analyzing, and diagnostic workstation computers. On-demand assessments of generator and auxiliary equipment performance are provided along with color trend displays comparing measured performance to reference-normal conditions

  6. Real time water chemistry monitoring and diagnostics

    International Nuclear Information System (INIS)

    Gaudreau, T.M.; Choi, S.S.

    2002-01-01

    EPRI has produced a real time water chemistry monitoring and diagnostic system. This system is called SMART ChemWorks and is based on the EPRI ChemWorks codes. System models, chemistry parameter relationships and diagnostic approaches from these codes are integrated with real time data collection, an intelligence engine and Internet technologies to allow for automated analysis of system chemistry. Significant data management capabilities are also included which allow the user to evaluate data and create automated reporting. Additional features have been added to the system in recent years including tracking and evaluation of primary chemistry as well as the calculation and tracking of primary to secondary leakage in PWRs. This system performs virtual sensing, identifies normal and upset conditions, and evaluates the consistency of on-line monitor and grab sample readings. The system also makes use of virtual fingerprinting to identify the cause of any chemistry upsets. This technology employs plant-specific data and models to determine the chemical state of the steam cycle. (authors)

  7. Advanced monitoring, fault diagnostics, and maintenance of cryogenic systems

    CERN Document Server

    Girone, Mario; Pezzetti, Marco

    In this Thesis, advanced methods and techniques of monitoring, fault diagnostics, and predictive maintenance for cryogenic processes and systems are described. In particular, in Chapter 1, mainstreams in research on measurement systems for cryogenic processes are reviewed with the aim of dening key current trends and possible future evolutions. Then, in Chapter 2, several innovative methods are proposed. A transducer based on a virtual ow meter is presented for monitoring helium distribution and consumption in cryogenic systems for particle accelerators [1]. Furthermore, a comprehensive metrological analysis of the proposed transducer for verifying the metrological performance and pointing out most critical uncertainty sources is described [2]. A model-based method for fault detection and early-stage isolation, able to work with few records of Frequency Response Function (FRF) on an unfaulty compressor, is then proposed [3]. To enrich the proposal, a distributed diagnostic procedure, based on a micro-genetic...

  8. IFMIF-LIPAc Beam Diagnostics. Profiling and Loss Monitoring Systems

    International Nuclear Information System (INIS)

    Egberts, J.

    2012-01-01

    The IFMIF accelerator will accelerate two 125 mA continuous wave (cw) deuteron beams up to 40 MeV and blasts them onto a liquid lithium target to release neutrons. The very high beam power of 10 MW pose unprecedented challenges for the accelerator development. Therefore, it was decided to build a prototype accelerator, the Linear IFMIF Prototype Accelerator (LIPAc), which has the very same beam characteristic, but is limited to 9 MeV only. In the frame of this thesis, diagnostics devices for IFMIF and LIPAc have been developed. The diagnostics devices consist of beam loss monitors and interceptive as well as non-interceptive profile monitors. For the beam loss monitoring system, ionization chambers and diamond detectors have been tested and calibrated for neutron and γ radiation in the energy range expected at LIPAc. During these tests, for the first time, diamond detectors were successfully operated at cryogenic temperatures. For the interceptive profilers, thermal simulations were performed to ensure safe operation. For the non-interceptive profiler, Ionization Profile Monitors (IPMs) were developed. A prototype has been built and tested, and based on the findings, the final IPMs were designed and built. To overcome the space charge of accelerator beam, a software algorithm was written to reconstruct the actual beam profile. (author) [fr

  9. Real-Time Remote Diagnostic Monitoring Test-bed in JET

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R. [Asociation Euratom/CIEMAT para Fusion, Madrid (Spain); Kneupner, K.; Purahoo, K. [EURATOM/UKAEA Fusion Association, Abingdon (United Kingdom); Vega, J.; Pereira, A.; Portas, A. [Association EuratomCIEMAT para Fusion, Madrid (Spain); De Arcas, G.; Lopez, J.M. [Universidad Politecnica de Madrid (Spain); Murari, A. [Consorzio RFX, Padova (Italy); Fonseca, A. [Associacao URATOM/IST, Lisboa (Portugal); Contributors, J.E. [JET-EFDA, Abingdon (United Kingdom)

    2009-07-01

    Based on the remote experimentation concept oriented to long pulse shots, a test-bed system has been implemented in JET. It integrates 2 functionalities. The first one is the real-time monitoring, on remote, of a reflectometer diagnostic, to visualize different data outputs and status information. The second one is the integration of dotJET (Diagnostic Overview Tool for JET), which internally provides at JET an overview about the current diagnostic systems state, in order to monitor, on remote, JET diagnostics status. The architecture of the system is formed by: the data generator components, the data distribution system, an access control service, and the client applications. In the test-bed there are two data generators: the acquisition equipment associated with the reflectometer diagnostic that generates data and status information, and dotJET server that centralize the access to the status information of JET diagnostics. The data distribution system has been implemented using a publishing-subscribing technology that receives data from data generators and redistributes them to client applications. And finally, for monitoring, a client application based on Java Web Start technology, and a dotJET client application have been used. There are 3 interesting results from this project. The first one is the analysis of different aspects (data formats, data frame rate, data resolution, etc) related with remote real-time diagnostic monitoring oriented to long pulse experiments. The second one is the definition and implementation of a flexible enough architecture, to be applied to different types of data generated from other diagnostics, and that fits with remote access requirements; and the third one is to have achieved a secure system, taking into account internal networks and firewalls aspects in JET, and securing the access from remote users. For this last issue, PAPI technology has been used, enabling access control based on user attributes, enabling mobile users to

  10. On-line monitoring system for utility boiler diagnostics

    International Nuclear Information System (INIS)

    Radovanovic, P.M.; Afgan, N.H.; Caralho, M.G.

    1997-01-01

    The paper deals with the new developed modular type Monitoring System for Utility Boiler Diagnostics. Each module is intended to assess the specific process and can be used as a stand alone application. Four modules are developed, namely: LTC - module for the on-line monitoring of parameters related to the life-time consumption of selected boiler components; TRD - module for the tube rupture detection by the position and working fluid Ieakage quantity; FAM - module for the boiler surfaces fouling (slagging) assessment and FLAP - module for visualization of the boiler furnace flame position. All four modules are tested on respective pilot plants built oil the 200 and 300 MWe utility boilers. Monitoring System is commercially available and can be realized in any combination of its modules depending on demands induced by the operational problems of specific boiler. Further development of Monitoring System is performed in accordance with the respective EU project on development of Boiler Expert System. (Author)

  11. Development of a majority vote decision module for a self-diagnostic monitoring system for an air-operated valve system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo Shin [Dept. of Information and Communication Engineering, Sejong University, Seoul (Korea, Republic of); Chai, Jang Bom [Dept. of Mechanical Engineering, Ajou University, Suwon (Korea, Republic of); Kim, In Taek [Dept. of Information and Communication Engineering, Myongji University, Yongin (Korea, Republic of)

    2015-08-15

    A self-diagnostic monitoring system is a system that has the ability to measure various physical quantities such as temperature, pressure, or acceleration from sensors scattered over a mechanical system such as a power plant, in order to monitor its various states, and to make a decision about its health status. We have developed a self-diagnostic monitoring system for an air-operated valve system to be used in a nuclear power plant. In this study, we have tried to improve the self-diagnostic monitoring system to increase its reliability. We have implemented three different machine learning algorithms, i.e., logistic regression, an artificial neural network, and a support vector machine. After each algorithm performs the decision process independently, the decision-making module collects these individual decisions and makes a final decision using a majority vote scheme. With this, we performed some simulations and presented some of its results. The contribution of this study is that, by employing more robust and stable algorithms, each of the algorithms performs the recognition task more accurately. Moreover, by integrating these results and employing the majority vote scheme, we can make a definite decision, which makes the self-diagnostic monitoring system more reliable.

  12. Development of a majority vote decision module for a self-diagnostic monitoring system for an air-operated valve system

    International Nuclear Information System (INIS)

    Kim, Woo Shin; Chai, Jang Bom; Kim, In Taek

    2015-01-01

    A self-diagnostic monitoring system is a system that has the ability to measure various physical quantities such as temperature, pressure, or acceleration from sensors scattered over a mechanical system such as a power plant, in order to monitor its various states, and to make a decision about its health status. We have developed a self-diagnostic monitoring system for an air-operated valve system to be used in a nuclear power plant. In this study, we have tried to improve the self-diagnostic monitoring system to increase its reliability. We have implemented three different machine learning algorithms, i.e., logistic regression, an artificial neural network, and a support vector machine. After each algorithm performs the decision process independently, the decision-making module collects these individual decisions and makes a final decision using a majority vote scheme. With this, we performed some simulations and presented some of its results. The contribution of this study is that, by employing more robust and stable algorithms, each of the algorithms performs the recognition task more accurately. Moreover, by integrating these results and employing the majority vote scheme, we can make a definite decision, which makes the self-diagnostic monitoring system more reliable

  13. Development of a Real-Time Thermal Performance Diagnostic Monitoring system Using Self-Organizing Neural Network for Kori-2 Nuclear Power Unit

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Seong, Poong Hyun

    1996-01-01

    In this work, a PC-based thermal performance monitoring system is developed for the nuclear power plants. the system performs real-time thermal performance monitoring and diagnosis during plant operation. Specifically, a prototype for the Kori-2 nuclear power unit is developed and examined is very difficult because the system structure is highly complex and the components are very much inter-related. In this study, some major diagnostic performance parameters are selected in order to represent the thermal cycle effectively and to reduce the computing time. The Fuzzy ARTMAP, a self-organizing neural network, is used to recognize the characteristic pattern change of the performance parameters in abnormal situation. By examination, the algorithm is shown to be ale to detect abnormality and to identify the fault component or the change of system operation condition successfully. For the convenience of operators, a graphical user interface is also constructed in this work. 5 figs., 3 tabs., 11 refs. (Author)

  14. Diagnostic tool for structural health monitoring: effect of material nonlinearity and vibro-impact process

    Science.gov (United States)

    Hiwarkar, V. R.; Babitsky, V. I.; Silberschmidt, V. V.

    2013-07-01

    Numerous techniques are available for monitoring structural health. Most of these techniques are expensive and time-consuming. In this paper, vibration-based techniques are explored together with their use as diagnostic tools for structural health monitoring. Finite-element simulations are used to study the effect of material nonlinearity on dynamics of a cracked bar. Additionally, several experiments are performed to study the effect of vibro-impact behavior of crack on its dynamics. It was observed that a change in the natural frequency of the cracked bar due to crack-tip plasticity and vibro-impact behavior linked to interaction of crack faces, obtained from experiments, led to generation of higher harmonics; this can be used as a diagnostic tool for structural health monitoring.

  15. Performance Assessment as a Diagnostic Tool for Science Teachers

    Science.gov (United States)

    Kruit, Patricia; Oostdam, Ron; van den Berg, Ed; Schuitema, Jaap

    2018-04-01

    Information on students' development of science skills is essential for teachers to evaluate and improve their own education, as well as to provide adequate support and feedback to the learning process of individual students. The present study explores and discusses the use of performance assessments as a diagnostic tool for formative assessment to inform teachers and guide instruction of science skills in primary education. Three performance assessments were administered to more than 400 students in grades 5 and 6 of primary education. Students performed small experiments using real materials while following the different steps of the empirical cycle. The mutual relationship between the three performance assessments is examined to provide evidence for the value of performance assessments as useful tools for formative evaluation. Differences in response patterns are discussed, and the diagnostic value of performance assessments is illustrated with examples of individual student performances. Findings show that the performance assessments were difficult for grades 5 and 6 students but that much individual variation exists regarding the different steps of the empirical cycle. Evaluation of scores as well as a more substantive analysis of students' responses provided insight into typical errors that students make. It is concluded that performance assessments can be used as a diagnostic tool for monitoring students' skill performance as well as to support teachers in evaluating and improving their science lessons.

  16. Performance Health Monitoring of Large-Scale Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamony, Ram [IBM Research, Austin, TX (United States)

    2014-11-20

    This report details the progress made on the ASCR funded project Performance Health Monitoring for Large Scale Systems. A large-­scale application may not achieve its full performance potential due to degraded performance of even a single subsystem. Detecting performance faults, isolating them, and taking remedial action is critical for the scale of systems on the horizon. PHM aims to develop techniques and tools that can be used to identify and mitigate such performance problems. We accomplish this through two main aspects. The PHM framework encompasses diagnostics, system monitoring, fault isolation, and performance evaluation capabilities that indicates when a performance fault has been detected, either due to an anomaly present in the system itself or due to contention for shared resources between concurrently executing jobs. Software components called the PHM Control system then build upon the capabilities provided by the PHM framework to mitigate degradation caused by performance problems.

  17. On-line surveillance system for Borssele nuclear power plant monitoring and diagnostics

    International Nuclear Information System (INIS)

    Tuerkcan, E.; Ciftcioglu, Oe.

    1993-08-01

    An operating on-line surveillance and diagnostic system is described where information processing for monitoring and fault diagnosis and plant maintenance are addressed. The surveillance system by means of its realtime multiprocessing, multitasking execution capabilities can perform plant-wide and wide-range monitoring for enhanced plant safety and operational reliability as well as enhanced maintenance. At the same time the system provides the possibilities for goal-oriented research and development such as estimation, filtering, verification and validation and neural networks. (orig./HP)

  18. Evaluation of the performance of diagnosis monitors in use in Salvador city: pilot study

    International Nuclear Information System (INIS)

    Garcia, Igor; Geambastiani, Paulo; Ferreira, Mario; Macedo, Eric; Navarro, Marcus; Navarro, Valeria; Pereira, Lara; Jesus, Evandro de; Leite, Handerson Jorge Dourado

    2016-01-01

    Radiologically, the image quality is the accuracy of the representation of the patient's anatomy. Considering the importance of the performance of the monitors to the overall effectiveness of a practice of diagnostic imaging, the objective of this study is to evaluate the performance of diagnostic monitors in use, using the method described in the report 03 of the AAPA and Spanish protocol, using calibrated instrumentation traceable to NIST and to RBC. The results of the monitors evaluated to date show 100% compliance for geometric distortion tests and internal reflection and 0% compliance to the dependence of luminance test. (author)

  19. Real-time remote diagnostic monitoring test-bed in JET

    International Nuclear Information System (INIS)

    Castro, R.; Kneupner, K.; Vega, J.; De Arcas, G.; Lopez, J.M.; Purahoo, K.; Murari, A.; Fonseca, A.; Pereira, A.; Portas, A.

    2010-01-01

    Based on the remote experimentation concept oriented to long pulse shots, a test-bed system has been implemented in JET. Its main functionality is the real-time monitoring, on remote, of a reflectometer diagnostic, to visualize different data outputs and status information. The architecture of the system is formed by: the data generator components, the data distribution system, an access control service, and the client applications. In the test-bed there is one data generator, which is the acquisition equipment associated with the reflectometer diagnostic that generates data and status information. The data distribution system has been implemented using a publishing-subscribing technology that receives data from data generators and redistributes them to client applications. And finally, for monitoring, a client application based on JAVA Web Start technology has been used. There are three interesting results from this project. The first one is the analysis of different aspects (data formats, data frame rate, data resolution, etc) related with remote real-time diagnostic monitoring oriented to long pulse experiments. The second one is the definition and implementation of an architecture, flexible enough to be applied to different types of data generated from other diagnostics, and that fits with remote access requirements. Finally, the third result is a secure system, taking into account internal networks and firewalls aspects of JET, and securing the access from remote users. For this last issue, PAPI technology has been used, enabling access control based on user attributes, enabling mobile users to monitor diagnostics in real-time, and enabling the integration of this service into the EFDA Federation (Castro et al., 2008 ).

  20. Real-time remote diagnostic monitoring test-bed in JET

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R., E-mail: rodrigo.castro@ciemat.e [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain); Kneupner, K. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Vega, J. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain); De Arcas, G.; Lopez, J.M. [Universidad Politecnica de Madrid, Grupo I2A2, Madrid (Spain); Purahoo, K. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Murari, A. [Associazione EURATOM-ENEA per la Fusione, Consorzio RFX, 4-35127 Padova (Italy); Fonseca, A. [Associacao EURATOM/IST, Lisbon (Portugal); Pereira, A.; Portas, A. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)

    2010-07-15

    Based on the remote experimentation concept oriented to long pulse shots, a test-bed system has been implemented in JET. Its main functionality is the real-time monitoring, on remote, of a reflectometer diagnostic, to visualize different data outputs and status information. The architecture of the system is formed by: the data generator components, the data distribution system, an access control service, and the client applications. In the test-bed there is one data generator, which is the acquisition equipment associated with the reflectometer diagnostic that generates data and status information. The data distribution system has been implemented using a publishing-subscribing technology that receives data from data generators and redistributes them to client applications. And finally, for monitoring, a client application based on JAVA Web Start technology has been used. There are three interesting results from this project. The first one is the analysis of different aspects (data formats, data frame rate, data resolution, etc) related with remote real-time diagnostic monitoring oriented to long pulse experiments. The second one is the definition and implementation of an architecture, flexible enough to be applied to different types of data generated from other diagnostics, and that fits with remote access requirements. Finally, the third result is a secure system, taking into account internal networks and firewalls aspects of JET, and securing the access from remote users. For this last issue, PAPI technology has been used, enabling access control based on user attributes, enabling mobile users to monitor diagnostics in real-time, and enabling the integration of this service into the EFDA Federation (Castro et al., 2008 ).

  1. Technical diagnostics - equipment monitoring for increasing safety and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Sturm, A.; Foerster, R.

    1977-01-01

    Utilization of technical diagnostics in equipment monitoring of nuclear power plants for ensuring nuclear safety, economic availability, and for decision making on necessary maintenance is reviewed. Technical diagnostics is subdivided into inspection and early detection of malfunctions. Moreover, combination of technical diagnostics and equipment monitoring, integration of technical diagnostics into maintenance strategy, and problems of introducing early detection of malfunctions into maintenance management of nuclear power plants are also discussed. In addition, a compilation of measuring techniques used in technical diagnostics has been made. The international state of the art of equipment monitoring in PWR nuclear power plants is illustrated by description of the sound and vibration measuring techniques. (author)

  2. Performance assessment and adoption processes of an information monitoring and diagnostic system prototype

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann

    1999-10-01

    This report addresses the problem that buildings do not perform as well as anticipated during design. We partnered with an innovative building operator to evaluate a prototype Information Monitoring and Diagnostic System (IMDS). The IMDS consists of high-quality measurements archived each minute, a data visualization tool, and a web-based capability. The operators recommend similar technology be adopted in other buildings. The IMDS has been used to identify and correct a series of control problems. It has also allowed the operators to make more effective use of the building control system, freeing up time to take care of other tenant needs. They believe they have significantly improved building comfort, potentially improving tenant health, and productivity. The reduction in hours to operate the building are worth about $20,000 per year, which could pay for the IMDS in about five years. A control system retrofit based on findings from the IMDS is expected to reduce energy use by 20 percent over the next year, worth over $30,000 per year. The main conclusion of the model-based chiller fault detection work is that steady-state models can be used as reference models to monitor chiller operation and detect faults. The ability of the IMDS to measure cooling load and chiller power to one-percent accuracy with a one-minute sampling interval permits detection of additional faults. Evolutionary programming techniques were also evaluated, showing promise in the detection of patterns in building data. We also evaluated two technology adoption processes, radical and routine. In routine adoption, managers enhance features of existing products that are already well understood. In radical adoption, innovative building managers introduce novel technology into their organizations without using the rigorous payback criteria used in routine innovations.

  3. Quantitative optical diagnostics in pathology recognition and monitoring of tissue reaction to PDT

    Science.gov (United States)

    Kirillin, Mikhail; Shakhova, Maria; Meller, Alina; Sapunov, Dmitry; Agrba, Pavel; Khilov, Alexander; Pasukhin, Mikhail; Kondratieva, Olga; Chikalova, Ksenia; Motovilova, Tatiana; Sergeeva, Ekaterina; Turchin, Ilya; Shakhova, Natalia

    2017-07-01

    Optical coherence tomography (OCT) is currently actively introduced into clinical practice. Besides diagnostics, it can be efficiently employed for treatment monitoring allowing for timely correction of the treatment procedure. In monitoring of photodynamic therapy (PDT) traditionally employed fluorescence imaging (FI) can benefit from complementary use of OCT. Additional diagnostic efficiency can be derived from numerical processing of optical diagnostics data providing more information compared to visual evaluation. In this paper we report on application of OCT together with numerical processing for clinical diagnostic in gynecology and otolaryngology, for monitoring of PDT in otolaryngology and on OCT and FI applications in clinical and aesthetic dermatology. Image numerical processing and quantification provides increase in diagnostic accuracy. Keywords: optical coherence tomography, fluorescence imaging, photod

  4. Hybrid Modeling Improves Health and Performance Monitoring

    Science.gov (United States)

    2007-01-01

    Scientific Monitoring Inc. was awarded a Phase I Small Business Innovation Research (SBIR) project by NASA's Dryden Flight Research Center to create a new, simplified health-monitoring approach for flight vehicles and flight equipment. The project developed a hybrid physical model concept that provided a structured approach to simplifying complex design models for use in health monitoring, allowing the output or performance of the equipment to be compared to what the design models predicted, so that deterioration or impending failure could be detected before there would be an impact on the equipment's operational capability. Based on the original modeling technology, Scientific Monitoring released I-Trend, a commercial health- and performance-monitoring software product named for its intelligent trending, diagnostics, and prognostics capabilities, as part of the company's complete ICEMS (Intelligent Condition-based Equipment Management System) suite of monitoring and advanced alerting software. I-Trend uses the hybrid physical model to better characterize the nature of health or performance alarms that result in "no fault found" false alarms. Additionally, the use of physical principles helps I-Trend identify problems sooner. I-Trend technology is currently in use in several commercial aviation programs, and the U.S. Air Force recently tapped Scientific Monitoring to develop next-generation engine health-management software for monitoring its fleet of jet engines. Scientific Monitoring has continued the original NASA work, this time under a Phase III SBIR contract with a joint NASA-Pratt & Whitney aviation security program on propulsion-controlled aircraft under missile-damaged aircraft conditions.

  5. Telecontrol - Expert systems. Real-time monitoring and remote diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Lam, A.

    1996-09-01

    The role of expert systems in programming simple and complex tasks in utilities companies was discussed with examples from B.C. Hydro, where expert systems have been used in such diverse applications as an in-house programmable logic controller (PLC) training course, and a machine audit on a 150 MW steam turbine generating unit at their Burrard Thermal Generating Plant. The PLC tutoring program uses expert system technology for the air blast circuit breakers` air drier system, for individualized on-site training. The steam turbine audits (an eight-month long project) were performed remotely by dialing an on-site computer configured with customized expert software. Details of these, and other potential applications, such as transformer monitoring and diagnostics, circuit breaker performance analysis, and information management, were described.

  6. Development and Optimisation of the SPS and LHC beam diagnostics based on Synchrotron Radiation monitors

    CERN Document Server

    AUTHOR|(CDS)2081364; Roncarolo, Federico

    Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams.
 Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments. A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing t...

  7. Performance assessment and adoption processes of an information monitoring and diagnostic system prototype; FINAL

    International Nuclear Information System (INIS)

    Piette, Mary Ann

    1999-01-01

    This report addresses the problem that buildings do not perform as well as anticipated during design. We partnered with an innovative building operator to evaluate a prototype Information Monitoring and Diagnostic System (IMDS). The IMDS consists of high-quality measurements archived each minute, a data visualization tool, and a web-based capability. The operators recommend similar technology be adopted in other buildings. The IMDS has been used to identify and correct a series of control problems. It has also allowed the operators to make more effective use of the building control system, freeing up time to take care of other tenant needs. They believe they have significantly improved building comfort, potentially improving tenant health, and productivity. The reduction in hours to operate the building are worth about$20,000 per year, which could pay for the IMDS in about five years. A control system retrofit based on findings from the IMDS is expected to reduce energy use by 20 percent over the next year, worth over$30,000 per year. The main conclusion of the model-based chiller fault detection work is that steady-state models can be used as reference models to monitor chiller operation and detect faults. The ability of the IMDS to measure cooling load and chiller power to one-percent accuracy with a one-minute sampling interval permits detection of additional faults. Evolutionary programming techniques were also evaluated, showing promise in the detection of patterns in building data. We also evaluated two technology adoption processes, radical and routine. In routine adoption, managers enhance features of existing products that are already well understood. In radical adoption, innovative building managers introduce novel technology into their organizations without using the rigorous payback criteria used in routine innovations

  8. Study on Practical Application of Turboprop Engine Condition Monitoring and Fault Diagnostic System Using Fuzzy-Neuro Algorithms

    Science.gov (United States)

    Kong, Changduk; Lim, Semyeong; Kim, Keunwoo

    2013-03-01

    The Neural Networks is mostly used to engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measuring performance data, and proposes a fault diagnostic system using the base performance model and artificial intelligent methods such as Fuzzy and Neural Networks. Each real engine performance model, which is named as the base performance model that can simulate a new engine performance, is inversely made using its performance test data. Therefore the condition monitoring of each engine can be more precisely carried out through comparison with measuring performance data. The proposed diagnostic system identifies firstly the faulted components using Fuzzy Logic, and then quantifies faults of the identified components using Neural Networks leaned by fault learning data base obtained from the developed base performance model. In leaning the measuring performance data of the faulted components, the FFBP (Feed Forward Back Propagation) is used. In order to user's friendly purpose, the proposed diagnostic program is coded by the GUI type using MATLAB.

  9. Intelligent monitoring of water chemistry - Diagnostic expert system DIWATM

    International Nuclear Information System (INIS)

    Metzner, W.; Streit, K.

    2002-01-01

    For fast and comprehensive evaluation of power plant water chemistry conditions and reliable diagnosis in the event of disturbances considerable advantages are provided by employment of the Diagnostic Expert System DIWA. The interface to the process control system (I and C) and the integration of the DIWA system in the office PC network are the preconditions that DIWA operates as a monitoring system in real time. The performance of diagnosis, which are processed by a fuzzy-logic-supported knowledge base ensures not only the detection of all disturbances but also different analyses of the plant operation mode. By editing the knowledge base the Al of the system can increase without system programming. (authors)

  10. Out of Hours Emergency Computed Tomography Brain Studies: Comparison of Standard 3 Megapixel Diagnostic Workstation Monitors With the iPad 2.

    Science.gov (United States)

    Salati, Umer; Leong, Sum; Donnellan, John; Kok, Hong Kuan; Buckley, Orla; Torreggiani, William

    2015-11-01

    The purpose was to compare performance of diagnostic workstation monitors and the Apple iPad 2 (Cupertino, CA) in interpretation of emergency computed tomography (CT) brain studies. Two experienced radiologists interpreted 100 random emergency CT brain studies on both on-site diagnostic workstation monitors and the iPad 2 via remote access. The radiologists were blinded to patient clinical details and to each other's interpretation and the study list was randomized between interpretations on different modalities. Interobserver agreement between radiologists and intraobserver agreement between modalities was determined and Cohen kappa coefficients calculated for each. Performance with regards to urgent and nonurgent abnormalities was assessed separately. There was substantial intraobserver agreement of both radiologists between the modalities with overall calculated kappa values of 0.959 and 0.940 in detecting acute abnormalities and perfect agreement with regards to hemorrhage. Intraobserver agreement kappa values were 0.939 and 0.860 for nonurgent abnormalities. Interobserver agreement between the 2 radiologists for both diagnostic monitors and the iPad 2 was also substantial ranging from 0.821-0.860. The iPad 2 is a reliable modality in the interpretation of CT brain studies in them emergency setting and for the detection of acute and chronic abnormalities, with comparable performance to standard diagnostic workstation monitors. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Monitoring the Diagnostic Process on an Inpatient Neurology Service.

    Science.gov (United States)

    Dhand, Amar; Bucelli, Robert; Varadhachary, Arun; Tsiaklides, Michael; de Bruin, Gabriela; Dhaliwal, Gurpreet

    2017-07-01

    The Institute of Medicine report Improving Diagnosis in Health Care called for tools to monitor physicians' diagnostic process. We addressed this need by developing a tool for clinicians to record and analyze their diagnostic process. The tool was a secure web application in which clinicians used a structured grading system to assess the relative impact of clinical, laboratory, and neuroimaging data for every new diagnosis. Four neurohospitalists used the tool for 6.5 months on a general neurology ward service at a single tertiary-level teaching hospital. Process measures of tool use included number of diagnoses entered, time spent on each data entry, and concordance of diagnoses compared to the medical record. We also aggregated the data across clinicians to examine the average process scores across common inpatient disorders. The 4 clinicians entered 254 new diagnoses that took approximately 3 minutes per patient. In 50 randomly chosen cases, the neurohospitalists' diagnoses entered into the tool agreed with 92% of diagnoses in the medical record, which was better than the agreement between billing code and medical record diagnoses (74%). The diagnostic process varied across disease categories, showing a spectrum of clinical-dominant (eg, headache), laboratory-dominant (eg, encephalitis), and neuroimaging-dominant (eg, stroke) disorders. This study demonstrated the feasibility of a clinician-driven diagnostic process monitoring system, along with preliminary characterization of the process for common disorders. The tracking of diagnostic process has the potential to promote reflection on clinical practice, deconstruct neurologists' clinical decision-making, and improve health-care safety.

  12. Process Diagnostics and Monitoring Using the Multipole Resonance Probe (MRP)

    Science.gov (United States)

    Harhausen, J.; Awakowicz, P.; Brinkmann, R. P.; Foest, R.; Lapke, M.; Musch, T.; Mussenbrock, T.; Oberrath, J.; Ohl, A.; Rolfes, I.; Schulz, Ch.; Storch, R.; Styrnoll, T.

    2011-10-01

    In this contribution we present the application of the MRP in an industrial plasma ion assisted deposition (PIAD) chamber (Leybold optics SYRUS-pro). The MRP is a novel plasma diagnostic which is suitable for an industrial environment - which means that the proposed method is robust, calibration free, and economical, and can be used for ideal and reactive plasmas alike. In order to employ the MRP as process diagnostics we mounted the probe on a manipulator to obtain spatially resolved information on the electron density and temperature. As monitoring tool the MRP is installed at a fixed position. Even during the deposition process it provides stable measurement results while other diagnostic methods, e.g. the Langmuir probe, may suffer from dielectric coatings. In this contribution we present the application of the MRP in an industrial plasma ion assisted deposition (PIAD) chamber (Leybold optics SYRUS-pro). The MRP is a novel plasma diagnostic which is suitable for an industrial environment - which means that the proposed method is robust, calibration free, and economical, and can be used for ideal and reactive plasmas alike. In order to employ the MRP as process diagnostics we mounted the probe on a manipulator to obtain spatially resolved information on the electron density and temperature. As monitoring tool the MRP is installed at a fixed position. Even during the deposition process it provides stable measurement results while other diagnostic methods, e.g. the Langmuir probe, may suffer from dielectric coatings. Funded by the German Ministry for Education and Research (BMBF, Fkz. 13N10462).

  13. Diagnostic and monitoring systems produced in Vuje, Okruzna 5, 918 64 Trnava, Slovak Republic

    International Nuclear Information System (INIS)

    Oksa, G.; Bahna, J.; Murin, V.; Kucharek, P.; Smutny, S.

    1996-01-01

    Based on the 20 years experience in on-line vibration diagnostics of mechanical components in the primary circuit of nuclear power plant PWR WWER-440, Vuje, Okruzna 5, 918 64 Trnava produces its own diagnostic and monitoring systems since 1990. The variety of diagnostic systems includes: loose part monitoring system (LPMS), monitoring system of main circulating pumps (MCPMS), vibration monitoring system (LVMS), leakage monitoring system (LMS). The emphasis in the hardware solution is put on the design modularity and versatility so that many subcomponents (circuit boards) are common or highly similar for all systems. Using exclusively digital data for processing enhances the reliability of the measurements and allows the easy data transportation from one computer to another (e.g., for more sophisticated analysis). Trends in the software development follow the similar path as for the hardware solution - namely, the modularity and versatility of software is the imperative goal. The modern operating systems also incorporate the ability of network communication, which is crucial for the integration of stand-alone diagnostic systems into nuclear power plants information system. So far a number of systems have been successfully installed: 6 LPMSs (Jaslovske Bohunice, Dukovany), 4 MCPMs (Jaslovske Bohunice) and 2 LVMSs (Jaslovske Bohunice), all systems operate in PWR WWER-440 environment. Another diagnostic systems are under construction: 2 LPMSs (Temelin, PWR WWER-1000), 2 MCMSs (Mochovce - PWR WWER-440) and 2 LMSs (Jaslovske Bohunice). (author). 1 fig

  14. Diagnostic and monitoring systems produced in Vuje, Okruzna 5, 918 64 Trnava, Slovak Republic

    Energy Technology Data Exchange (ETDEWEB)

    Oksa, G; Bahna, J; Murin, V; Kucharek, P; Smutny, S [Vyskumny Ustav Jadrovych Elektrarni, Trnava (Slovakia)

    1997-12-31

    Based on the 20 years experience in on-line vibration diagnostics of mechanical components in the primary circuit of nuclear power plant PWR WWER-440, Vuje, Okruzna 5, 918 64 Trnava produces its own diagnostic and monitoring systems since 1990. The variety of diagnostic systems includes: loose part monitoring system (LPMS), monitoring system of main circulating pumps (MCPMS), vibration monitoring system (LVMS), leakage monitoring system (LMS). The emphasis in the hardware solution is put on the design modularity and versatility so that many subcomponents (circuit boards) are common or highly similar for all systems. Using exclusively digital data for processing enhances the reliability of the measurements and allows the easy data transportation from one computer to another (e.g., for more sophisticated analysis). Trends in the software development follow the similar path as for the hardware solution - namely, the modularity and versatility of software is the imperative goal. The modern operating systems also incorporate the ability of network communication, which is crucial for the integration of stand-alone diagnostic systems into nuclear power plants information system. So far a number of systems have been successfully installed: 6 LPMSs (Jaslovske Bohunice, Dukovany), 4 MCPMs (Jaslovske Bohunice) and 2 LVMSs (Jaslovske Bohunice), all systems operate in PWR WWER-440 environment. Another diagnostic systems are under construction: 2 LPMSs (Temelin, PWR WWER-1000), 2 MCMSs (Mochovce - PWR WWER-440) and 2 LMSs (Jaslovske Bohunice). (author). 1 fig.

  15. Use of EEG workload indices for diagnostic monitoring of vigilance decrement.

    Science.gov (United States)

    Kamzanova, Altyngul T; Kustubayeva, Almira M; Matthews, Gerald

    2014-09-01

    A study was run to test which of five electroencephalographic (EEG) indices was most diagnostic of loss of vigilance at two levels of workload. EEG indices of alertness include conventional spectral power measures as well as indices combining measures from multiple frequency bands, such as the Task Load Index (TLI) and the Engagement Index (El). However, it is unclear which indices are optimal for early detection of loss of vigilance. Ninety-two participants were assigned to one of two experimental conditions, cued (lower workload) and uncued (higher workload), and then performed a 40-min visual vigilance task. Performance on this task is believed to be limited by attentional resource availability. EEG was recorded continuously. Performance, subjective state, and workload were also assessed. The task showed a vigilance decrement in performance; cuing improved performance and reduced subjective workload. Lower-frequency alpha (8 to 10.9 Hz) and TLI were most sensitive to the task parameters. The magnitude of temporal change was larger for lower-frequency alpha. Surprisingly, higher TLI was associated with superior performance. Frontal theta and El were influenced by task workload only in the final period of work. Correlational data also suggested that the indices are distinct from one another. Lower-frequency alpha appears to be the optimal index for monitoring vigilance on the task used here, but further work is needed to test how diagnosticity of EEG indices varies with task demands. Lower-frequency alpha may be used to diagnose loss of operator alertness on tasks requiring vigilance.

  16. An integrated framework for online diagnostic and prognostic health monitoring using a multistate deterioration process

    International Nuclear Information System (INIS)

    Moghaddass, Ramin; Zuo, Ming J.

    2014-01-01

    Efficient asset management is of paramount importance, particularly for systems with costly downtime and failure. As in energy and capital-intensive industries, the economic loss of downtime and failure is huge, the need for a low-cost and integrated health monitoring system has increased significantly over the years. Timely detection of faults and failures through an efficient prognostics and health management (PHM) framework can lead to appropriate maintenance actions to be scheduled proactively to avoid catastrophic failures and minimize the overall maintenance cost of the systems. This paper aims at practical challenges of online diagnostics and prognostics of mechanical systems under unobservable degradation. First, the elements of a multistate degradation structure are reviewed and then a model selection framework is introduced. Important dynamic performance measures are introduced, which can be used for online diagnostics and prognostics. The effectiveness of the result of this paper is demonstrated with a case study on the health monitoring of turbofan engines

  17. Online monitoring and diagnostic system on RA-6 nuclear reactor

    International Nuclear Information System (INIS)

    Garcia Peyrano, O. A.; Marticorena, M.; Koch, R. G.; Martinez, J. S; Berruti, G. E.; Nunez, W. M.; Gonzales, L. A.; Tarquini, L. D.; Sotelo, J. P

    2009-01-01

    This paper presents the Online Automatic Monitoring and Diagnostic System for mechanical components, installed on RA-6 Nuclear Reactor (San Carlos de Bariloche, Argentina). This system has been designed, installed and set-up by the Vibrations and Mechatronics Laboratory (Centro Atomico Bariloche, Comision Nacional de Energia Atomica) and Sitrack.com Argentina SA. This system provides an online mechanical diagnostic of the main reactor components, allowing incipient failures to be early detected and identified, avoiding unscheduled shut-downs and reducing maintenance times. The diagnostic is accomplished by an online analysis of the vibratory signature of the mechanical components, obtained by vibrations sensors on the main pump and the decay tank. The mechanical diagnostic and the main operational parameters are displayed on the reactor control room and published on the internet. [es

  18. Final Report on the Research Project Ringhals Diagnostics and Monitoring. Stage 4

    International Nuclear Information System (INIS)

    Demaziere, C.; Arzhanov, V.; Karlsson, Joakim K.H.; Pazsit, I.

    1999-01-01

    This report gives an account of the work performed by the Department of Reactor Physics in the frame of a research contract with Ringhals, Vattenfall AB. The contract constitutes Stage 4 of a long-term co-operative research work concerning diagnostics and monitoring of the BWR and PWR units. The work in Stage 4 has been performed between 1 October 1998 and 1 September 1999. In Stage 4 we have worked with four items as follows: 1. Regional modes in R1 stability measurements; 2. Analysis of data from the measurement 980604; 3. Study of the possibility of measuring the moderator temperature coefficient using noise methods. Literature survey and measurement evaluation; 4. Transfer of the method for determining axial control rod elevation. Current situation and progress

  19. Diagnostics for Evaluating Performance of NSTX Liquid Lihium Divertor

    Science.gov (United States)

    Kaita, R.; Kugel, H.; Kallman, J.; Leblanc, B.; Paul, S.; Roquemore, A. L.; Skinner, C.; Soukhanovskii, V.; Maingi, R.; Ahn, J.-W.; Wilgen, J.; Allain, J.-P.; Taylor, C.

    2009-11-01

    A Liquid Lithium Divertor (LLD) is being installed on NSTX to investigate particle control and power handling with liquid lithium as plasma-facing component (PFC). The LLD is expected to provide a low-recycling plasma-facing component (PFC). To study the effects of such a PFC on plasma performance, a variety of edge measurements are required. Since its surface is highly reflective at visible wavelengths, a Lyman-alpha detector array will be used to monitor the recycling. To understand changes in edge transport, electron temperature and density measurements will be made with Langmuir probes mounted in PFC's near the LLD, and the edge sightlines of a multipoint Thomson scattering system. A frequency-scanning reflectometer will also provide scrapeoff layer electron density profiles. The LLD response to heat loads will be examined with infrared cameras and thermocouples. Diagnostics are also needed to measure the erosion and codeposition of lithium. They include quartz deposition monitors and a retractable probe for exposing samples to the plasma.

  20. NPP Temelin automatic monitoring and diagnostic system of secondary side of the unit 1

    International Nuclear Information System (INIS)

    Heidenreich, S.; Pisl, M.; Drab, F.

    1997-01-01

    Two measuring and evaluating systems by SKODA PRAHA are described, designed for the Temelin nuclear power plant: a permanent secondary side diagnostic system for technology monitoring in the period of startup and operation; and the system of physical and power starting-up for monitoring during the first and repeated startup. The purposes of both systems are outlined. The scope of diagnostics covered and the functioning of the secondary side system is dealt with in some detail. (A.K.)

  1. Chemistry monitoring and diagnostic system at NPP Jaslovske Bohunice

    International Nuclear Information System (INIS)

    Smiesko, Ivan; Figedy, Stefan

    2012-09-01

    This paper provides a description of water chemistry monitoring and diagnostic system installed at Slovak NPP Jaslovske Bohunice. System has complex architecture and covers laboratory data, chemistry and radiochemistry on-line monitoring data, process data acquisition and processing and diagnostics. Pre-filtered data from process computer and chemistry on-line monitors are recorded together with laboratory data in the ORACLE-based information system CHEMIS with many presentation and processing features. Brief information is given about the basic features of a newly developed diagnostic system for early detection and identification of anomalies incoming in the water chemistry regime of the primary and secondary circuit of VVER-440 type unit. This system, called SACHER (System of Analysis of Chemical Regime) has been installed within the major modernization project at the NPP Bohunice in the Slovak Republic. System SACHER has been developed fully in MATLAB environment. Diagnostic system works exclusively with available on-line data as an operation personnel support application allowing effective response to adverse chemistry events/trends. The availability of prompt information about the chemical conditions of the primary and secondary circuit is very important in order to prevent the undue corrosion and deposit build-up processes within the plant systems. The typical chemical information systems that exist and work at the NPPs give the user values of the measured quantities together with their time trends and other derived values. It is then the experienced user's role to recognize the situation the monitored process is in and make the subsequent decisions and take the measures. The SACHER system, based on the computational intelligence techniques, inserts the elements of intelligence into the overall chemical information system. It has the modular structure with the following most important modules: - normality module- its aim is to recognize that the process

  2. Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Patrick O' Neill

    2009-06-30

    This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested on two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests

  3. Automated System of Diagnostic Monitoring at Bureya HPP Hydraulic Engineering Installations: a New Level of Safety

    Energy Technology Data Exchange (ETDEWEB)

    Musyurka, A. V., E-mail: musyurkaav@burges.rushydro.ru [Bureya HPP (a JSC RusGidro affiliate) (Russian Federation)

    2016-09-15

    This article presents the design, hardware, and software solutions developed and placed in service for the automated system of diagnostic monitoring (ASDM) for hydraulic engineering installations at the Bureya HPP, and assuring a reliable process for monitoring hydraulic engineering installations. Project implementation represents a timely solution of problems addressed by the hydraulic engineering installation diagnostics section.

  4. Automated System of Diagnostic Monitoring at Bureya HPP Hydraulic Engineering Installations: a New Level of Safety

    International Nuclear Information System (INIS)

    Musyurka, A. V.

    2016-01-01

    This article presents the design, hardware, and software solutions developed and placed in service for the automated system of diagnostic monitoring (ASDM) for hydraulic engineering installations at the Bureya HPP, and assuring a reliable process for monitoring hydraulic engineering installations. Project implementation represents a timely solution of problems addressed by the hydraulic engineering installation diagnostics section.

  5. Monitoring endemic livestock diseases using laboratory diagnostic data: A simulation study to evaluate the performance of univariate process monitoring control algorithms.

    Science.gov (United States)

    Lopes Antunes, Ana Carolina; Dórea, Fernanda; Halasa, Tariq; Toft, Nils

    2016-05-01

    Surveillance systems are critical for accurate, timely monitoring and effective disease control. In this study, we investigated the performance of univariate process monitoring control algorithms in detecting changes in seroprevalence for endemic diseases. We also assessed the effect of sample size (number of sentinel herds tested in the surveillance system) on the performance of the algorithms. Three univariate process monitoring control algorithms were compared: Shewart p Chart(1) (PSHEW), Cumulative Sum(2) (CUSUM) and Exponentially Weighted Moving Average(3) (EWMA). Increases in seroprevalence were simulated from 0.10 to 0.15 and 0.20 over 4, 8, 24, 52 and 104 weeks. Each epidemic scenario was run with 2000 iterations. The cumulative sensitivity(4) (CumSe) and timeliness were used to evaluate the algorithms' performance with a 1% false alarm rate. Using these performance evaluation criteria, it was possible to assess the accuracy and timeliness of the surveillance system working in real-time. The results showed that EWMA and PSHEW had higher CumSe (when compared with the CUSUM) from week 1 until the end of the period for all simulated scenarios. Changes in seroprevalence from 0.10 to 0.20 were more easily detected (higher CumSe) than changes from 0.10 to 0.15 for all three algorithms. Similar results were found with EWMA and PSHEW, based on the median time to detection. Changes in the seroprevalence were detected later with CUSUM, compared to EWMA and PSHEW for the different scenarios. Increasing the sample size 10 fold halved the time to detection (CumSe=1), whereas increasing the sample size 100 fold reduced the time to detection by a factor of 6. This study investigated the performance of three univariate process monitoring control algorithms in monitoring endemic diseases. It was shown that automated systems based on these detection methods identified changes in seroprevalence at different times. Increasing the number of tested herds would lead to faster

  6. EnergiTools(R) - a power plant performance monitoring and diagnosis tool

    International Nuclear Information System (INIS)

    Ancion, P.V.; Bastien, R.; Ringdahl, K.

    2000-01-01

    Westinghouse EnergiTools(R) is a performance diagnostic tool for power generation plants that combines the power of on-line process data acquisition with advanced diagnostics methodologies. The system uses analytical models based on thermodynamic principles combined with knowledge of component diagnostic experts. An issue in modeling expert knowledge is to have a framework that can represent and process uncertainty in complex systems. In such experiments, it is nearly impossible to build deterministic models for the effects of faults on symptoms. A methodology based on causal probabilistic graphs, more specifically on Bayesian belief networks, has been implemented in EnergiTools(R) to capture the fault-symptom relationships. The methodology estimates the likelihood of the various component failures using the fault-symptom relationships. The system also has the ability to use neural networks for processes that are difficult to model analytically. An application is the estimation of the reactor power in nuclear power plant by interpreting several plant indicators. EnergiTools(R) is used for the on-line performance monitoring and diagnostics at Vattenfall Ringhals nuclear power plants in Sweden. It has led to the diagnosis of various performance issues with plant components. Two case studies are presented. In the first case, an overestimate of the thermal power due to a faulty instrument was found, which led to a plant operation below its optimal power. The paper shows how the problem was discovered, using the analytical thermodynamic calculations. The second case shows an application of EnergiTools(R) for the diagnostic of a condenser failure using causal probabilistic graphs

  7. New developments in the surveillance and diagnostics technology for vibration, structure-borne sound and leakage monitoring systems

    International Nuclear Information System (INIS)

    Gloth, Gerrit

    2009-01-01

    Monitoring and diagnostic systems are of main importance for a safe and efficient operation of nuclear power plants. The author describes new developments with respect to vibration monitoring with a functional extension in the time domain for den secondary circuit, the development of a local system for the surveillance of rotating machines, the structure-borne sound monitoring with improvement of event analysis, esp. the loose part locating, leakage monitoring with a complete system for humidity measurement, and the development of a common platform for all monitoring and diagnostic systems, that allows an efficient access for comparison and cross references.

  8. MONITORING DIAGNOSTIC INDICATORS DURING OPERATION OF A PRINT MACHIN

    Directory of Open Access Journals (Sweden)

    Jozef Dobránsky

    2015-11-01

    Full Text Available This article deals with monitoring diagnostic indicators during the operation of a machine used for production of packing materials with a print. It analyses low-frequency vibrations measured in individual spherical roller bearings in eight print positions. The rollers in these positions have a different pressure based on positioning these rollers in relation to the central roller. As a result, the article also deals with a correlation of pressure and level of measured low-frequency vibrations. The speed of the print machine (the speed of a line in meters per minute is a very important variable during its operation, this is why it is important to verify the values of vibrations in various speeds of the line, what can lead to revelation of one or more resonance areas. Moreover, it examines vibrations of the central roller drive and measurement of backlash of transmission cogs of this drive. Based on performed analyses recommendations for an operator of the machine have been conceived.

  9. Development of an integrated condition monitoring and diagnostic system for motor-operated valves used in nuclear power plant

    International Nuclear Information System (INIS)

    Carneiro, Alvaro Luiz Guimaraes

    2003-01-01

    the MATLAB platform, which is a powerful language with high performance. The developed system has provided good results establishing a new qualitative methodology for monitoring and diagnostic of motor operated valves. (author)

  10. Study on Fault Diagnostics of a Turboprop Engine Using Inverse Performance Model and Artificial Intelligent Methods

    Science.gov (United States)

    Kong, Changduk; Lim, Semyeong

    2011-12-01

    Recently, the health monitoring system of major gas path components of gas turbine uses mostly the model based method like the Gas Path Analysis (GPA). This method is to find quantity changes of component performance characteristic parameters such as isentropic efficiency and mass flow parameter by comparing between measured engine performance parameters such as temperatures, pressures, rotational speeds, fuel consumption, etc. and clean engine performance parameters without any engine faults which are calculated by the base engine performance model. Currently, the expert engine diagnostic systems using the artificial intelligent methods such as Neural Networks (NNs), Fuzzy Logic and Genetic Algorithms (GAs) have been studied to improve the model based method. Among them the NNs are mostly used to the engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base if there are large amount of learning data. In addition, it has a very complex structure for finding effectively single type faults or multiple type faults of gas path components. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measured performance data, and proposes a fault diagnostic system using the base engine performance model and the artificial intelligent methods such as Fuzzy logic and Neural Network. The proposed diagnostic system isolates firstly the faulted components using Fuzzy Logic, then quantifies faults of the identified components using the NN leaned by fault learning data base, which are obtained from the developed base performance model. In leaning the NN, the Feed Forward Back Propagation (FFBP) method is used. Finally, it is verified through several test examples that the component faults implanted arbitrarily in the engine are well isolated and quantified by the proposed diagnostic system.

  11. Wind Turbine Bearing Diagnostics Based on Vibration Monitoring

    Science.gov (United States)

    Kadhim, H. T.; Mahmood, F. H.; Resen, A. K.

    2018-05-01

    Reliability maintenance can be considered as an accurate condition monitoring system which increasing beneficial and decreasing the cost production of wind energy. Supporting low friction of wind turbine rotating shaft is the main task of rolling element bearing and it is the main part that suffers from failure. The rolling failures elements have an economic impact and may lead to malfunctions and catastrophic failures. This paper concentrates on the vibration monitoring as a Non-Destructive Technique for assessing and demonstrates the feasibility of vibration monitoring for small wind turbine bearing defects based on LabVIEW software. Many bearings defects were created, such as inner race defect, outer race defect, and ball spin defect. The spectra data were recorded and compared with the theoretical results. The accelerometer with 4331 NI USB DAQ was utilized to acquiring, analyzed, and recorded. The experimental results were showed the vibration technique is suitable for diagnostic the defects that will be occurred in the small wind turbine bearings and developing a fault in the bearing which leads to increasing the vibration amplitude or peaks in the spectrum.

  12. Developing an automated database for monitoring ultrasound- and computed tomography-guided procedure complications and diagnostic yield.

    Science.gov (United States)

    Itri, Jason N; Jones, Lisa P; Kim, Woojin; Boonn, William W; Kolansky, Ana S; Hilton, Susan; Zafar, Hanna M

    2014-04-01

    Monitoring complications and diagnostic yield for image-guided procedures is an important component of maintaining high quality patient care promoted by professional societies in radiology and accreditation organizations such as the American College of Radiology (ACR) and Joint Commission. These outcome metrics can be used as part of a comprehensive quality assurance/quality improvement program to reduce variation in clinical practice, provide opportunities to engage in practice quality improvement, and contribute to developing national benchmarks and standards. The purpose of this article is to describe the development and successful implementation of an automated web-based software application to monitor procedural outcomes for US- and CT-guided procedures in an academic radiology department. The open source tools PHP: Hypertext Preprocessor (PHP) and MySQL were used to extract relevant procedural information from the Radiology Information System (RIS), auto-populate the procedure log database, and develop a user interface that generates real-time reports of complication rates and diagnostic yield by site and by operator. Utilizing structured radiology report templates resulted in significantly improved accuracy of information auto-populated from radiology reports, as well as greater compliance with manual data entry. An automated web-based procedure log database is an effective tool to reliably track complication rates and diagnostic yield for US- and CT-guided procedures performed in a radiology department.

  13. Efficient diagnostic methods for nuclear power plant monitoring

    International Nuclear Information System (INIS)

    Sunder, R.

    1997-01-01

    There are systems for operational monitoring of vibrations, valves, solid-borne sound, leaks, and embrittlement. The paper focuses on vibration monitoring of pressurized components and systems in PWRs and BWRs. Other than with conventional systems, the task is not to globally monitor the vibration level, but the frequency-selective information is used as a sensitive information source, the level of vibrations being of secondary significance. The essential feature therefore is the comprehensive and selective scanning of individual frequency components in the recorded vibration spectra, which in some cases can be less than a millesimal millimeter. Upon identification of the various vibration components - from so-called baseline analyses using correlation methods - vibration analysis is done by only one step, comparing a defined reference state with the actual vibration state of the monitored system component. In the event of detected deviations, information on the causes of vibrations - essentially component-related structural resonances - will give the relevant cause-effect relationship. The paper uses some practical examples to illustrate that reliable diagnoses are achieved by the above-mentioned frequency-selective technique. It is important, however, to carry out a sufficiently reliable statistical verification of diagnostic data by means of vibration trending. This is ensured with the digital systems and their high data acquisition rates. (orig./CB) [de

  14. Building a satellite climate diagnostics data base for real-time climate monitoring

    International Nuclear Information System (INIS)

    Ropelewski, C.F.

    1991-01-01

    The paper discusses the development of a data base, the Satellite Climate Diagnostic Data Base (SCDDB), for real time operational climate monitoring utilizing current satellite data. Special attention is given to the satellite-derived quantities useful for monitoring global climate changes, the requirements of SCDDB, and the use of conventional meteorological data and model assimilated data in developing the SCDDB. Examples of prototype SCDDB products are presented. 10 refs

  15. EnergiTools. A methodology for performance monitoring and diagnosis

    International Nuclear Information System (INIS)

    Ancion, P.; Bastien, R.; Ringdahl, K.

    2000-01-01

    EnergiTools is a performance monitoring and diagnostic tool that combines the power of on-line process data acquisition with advanced diagnosis methodologies. Analytical models based on thermodynamic principles are combined with neural networks to validate sensor data and to estimate missing or faulty measurements. Advanced diagnostic technologies are then applied to point out potential faults and areas to be investigated further. The diagnosis methodologies are based on Bayesian belief networks. Expert knowledge is captured in the form of the fault-symptom relationships and includes historical information as the likelihood of faults and symptoms. The methodology produces the likelihood of component failure root causes using the expert knowledge base. EnergiTools is used at Ringhals nuclear power plants. It has led to the diagnosis of various performance issues. Three case studies based on this plant data and model are presented and illustrate the diagnosis support methodologies implemented in EnergiTools . In the first case, the analytical data qualification technique points out several faulty measurements. The application of a neural network for the estimation of the nuclear reactor power by interpreting several plant indicators is then illustrated. The use of the Bayesian belief networks is finally described. (author)

  16. Expert system for diagnostics and status monitoring of NPP water chemistry condition

    International Nuclear Information System (INIS)

    Shvedova, M.N.; Kritski, V.G.; Zakharova, S.V.; Benediktov, V.B.; Nikolaev, F.V.

    2002-01-01

    Water chemistry condition (WCC) has been the subject of constant study and improvement up to the present day. It is connected with the presence of a direct relationship between the violation of water chemistry regulation on the one hand and components reliability of the circuit's equipment and cost-effectiveness of their operation on the other. It dictates the necessity to apply different optimization methods in the field of monitoring and use of information analytical and diagnostic systems to assess WCC quality, control and support. LI ''VNIPIET'' employees have, for several years, been developing an expert diagnostic system for supporting WCC and status monitoring of RBMK - reactor NPPs [2]. This system has not only conveniently organized the traditional functions of information acquisition and storage, a complete presentation of information in the form of tables, graphs of a dynamical changes of parameters and formation regular reports, diagnostic functions and issuing recommendations on WCC correction, but it also allows the assessment of confidence in the diagnosis made, relying on a wide range of numerical estimates, which were calculated by the use of expert data, and to make a credible prediction of an existing situation development. (authors)

  17. A self-diagnostic adhesive for monitoring bonded joints in aerospace structures

    Science.gov (United States)

    Zhuang, Yitao; Li, Yu-hung; Kopsaftopoulos, Fotis; Chang, Fu-Kuo

    2016-04-01

    Bondline integrity is still one of the most critical concerns in the design of aircraft structures up to date. Due to the lack of confidence on the integrity of the bondline both during fabrication and service, the industry standards and regulations still require assembling the composite using conventional fasteners. Furthermore, current state-of-the-art non-destructive evaluation (NDE) and structural health monitoring (SHM) techniques are incapable of offering mature solutions on the issue of bondline integrity monitoring. Therefore, the objective of this work is the development of an intelligent adhesive film with integrated micro-sensors for monitoring the integrity of the bondline interface. The proposed method makes use of an electromechanical-impedance (EMI) based method, which is a rapidly evolving approach within the SHM family. Furthermore, an innovative screen-printing technique to fabricate piezoelectric ceramic sensors with minimal thickness has been developed at Stanford. The approach presented in this study is based on the use of (i) micro screen-printed piezoelectric sensors integrated into adhesive leaving a minimal footprint on the material, (ii) numerical and analytical modeling of the EMI spectrum of the adhesive bondline, (iii) novel diagnostic algorithms for monitoring the bondline integrity based on advanced signal processing techniques, and (iv) the experimental assessment via prototype adhesively bonded structures in static (varying loads) and dynamic (fatigue) environments. The proposed method will provide a huge confidence on the use of bonded joints for aerospace structures and lead to a paradigm change in their design by enabling enormous weight savings while maximizing the economic and performance efficiency.

  18. Computer-based diagnostic monitoring to enhance the human-machine interface of complex processes

    International Nuclear Information System (INIS)

    Kim, I.S.

    1992-02-01

    There is a growing interest in introducing an automated, on-line, diagnostic monitoring function into the human-machine interfaces (HMIs) or control rooms of complex process plants. The design of such a system should be properly integrated with other HMI systems in the control room, such as the alarms system or the Safety Parameter Display System (SPDS). This paper provides a conceptual foundation for the development of a Plant-wide Diagnostic Monitoring System (PDMS), along with functional requirements for the system and other advanced HMI systems. Insights are presented into the design of an efficient and robust PDMS, which were gained from a critical review of various methodologies developed in the nuclear power industry, the chemical process industry, and the space technological community

  19. Non-Destructive Testing for Building Diagnostics and Monitoring: Experience Achieved with Case Studies

    Directory of Open Access Journals (Sweden)

    Tavukçuoğlu Ayşe

    2018-01-01

    Full Text Available Building inspection on site, in other words in-situ examinations of buildings is a troublesome work that necessitates the use of non-destructive investigation (NDT techniques. One of the main concerns of non-destructive testing studies is to improve in-situ use of NDT techniques for diagnostic and monitoring studies. The quantitative infrared thermography (QIRT and ultrasonic pulse velocity (UPV measurements have distinct importance in that regard. The joint use of QIRT and ultrasonic testing allows in-situ evaluation and monitoring of historical structures and contemporary ones in relation to moisture, thermal, materials and structural failures while the buildings themselves remain intact. For instances, those methods are useful for detection of visible and invisible cracks, thermal bridges and damp zones in building materials, components and functional systems as well as for soundness assessment of materials and thermal performance assessment of building components. In addition, those methods are promising for moisture content analyses in materials and monitoring the success of conservation treatments or interventions in structures. The in-situ NDT studies for diagnostic purposes should start with the mapping of decay forms and scanning of building surfaces with infrared images. Quantitative analyses are shaped for data acquisition on site and at laboratory from representative sound and problem areas in structures or laboratory samples. Laboratory analyses are needed to support in-situ examinations and to establish the reference data for better interpretation of in situ data. Advances in laboratory tests using IRT and ultrasonic testing are guiding for in-situ materials investigations based on measurable parameters. The knowledge and experience on QIRT and ultrasonic testing are promising for the innovative studies on today’s materials technologies, building science and conservation/maintenance practices. Such studies demand a multi

  20. SU-F-I-61: Assessment and Characterization of the Built-in Internal Photometer of Primary Diagnostic Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Ruuge, A; Erdi, Y; Mahmood, U [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: The conformance of Primary Diagnostic Monitors (PDMs) to the DICOM GSDF is increasingly required by several state and city regulators. Our purpose was to quantitatively characterize the luminance performance of the internal, built in photometer of BARCO monitors against an externally calibrated luminance meter. Methods: Thirty one PDMs (BARCO) were included in our analysis. An externally calibrated photometer (RaySafe Solo Light) was used to measure the luminance and illuminance values. Measured monitors were located at various hospital sites, radiology physicians’ offices and radiology reading rooms. All measured PDMs were equipped with the manufacturer’s built-in photometers and connected to Barco MediCal QA web service for manual and automatic quality control measurements. PDM combinations included 1, 2 and 4 monitors depending on the location. TG-18 and SMPTE test patterns were used to evaluate monitor performance. Results: All the PDMs exceeded the luminance ratio of 250:1, as required by NYC PDM guidelines. One PDM failed the NYC requirement for the minimal luminance level of 350 cd/m2. As compared to the external photometer, the difference in measurement of the maximum luminance with the built-in photometer was found to exceed 5% on 6 of the PDM measured, with a maximum deviation of 10%. The age of the monitors that failed was on average 5 years. All monitors passed the luminance uniformity test, which was 30% from the center of the monitor to the 4 corner locations. Four PDMs failed the Gray Scale Display Function (GSDF) calibration. Conclusion: For the consistent display of medical images and continued conformance with the DICOM GSDF standard, it is essential to compare the performance of the built-in photometer with an externally calibrated photometer for monitors that are older than 5 years.

  1. Development of advanced diagnostic technologies for motor-operated valves

    International Nuclear Information System (INIS)

    Hegi, Kotaro; Shimizu, Shunichi; Higuma, Koji; Nishino, Koji; Osaki, Kenji; Watanabe, Kazumi; Hamano, Frank

    2010-01-01

    As use of condition-based maintenance is allowed in the new regulatory inspection system employed in Japan's nuclear power plants in 2009, development of advanced diagnostic technologies for motor-operated valves (MOVs) is now required. This report discusses advanced technologies in valve-setup verification, valve performance evaluation, monitoring of valve/actuator conditions by performance diagnostic system and moreover detection of stem crack by ultrasonic diagnostic system. (author)

  2. Scramjet Performance Assessment Using Water Absorption Diagnostics (U)

    Science.gov (United States)

    Cavolowsky, John A.; Loomis, Mark P.; Deiwert, George

    1995-01-01

    Simultaneous multiple path measurements of temperature and H2O concentration will be presented for the AIMHYE test entries in the NASA Ames 16-Inch Shock Tunnel. Monitoring the progress of high temperature chemical reactions that define scramjet combustor efficiencies is a task uniquely suited to nonintrusive optical diagnostics. One application strategy to overcome the many challenges and limitations of nonintrusive measurements is to use laser absorption spectroscopy coupled with optical fibers. Absorption spectroscopic techniques with rapidly tunable lasers are capable of making simultaneous measurements of mole fraction, temperature, pressure, and velocity. The scramjet water absorption diagnostic was used to measure combustor efficiency and was compared to thrust measurements using a nozzle force balance and integrated nozzle pressures to develop a direct technique for evaluating integrated scramjet performance. Tests were initially performed with a diode laser tuning over a water absorption feature at 1391.7 nm. A second diode laser later became available at a wavelength near 1343.3 nm covering an additional water absorption feature and was incorporated in the system for a two-wavelength technique. Both temperature and mole fraction can be inferred from the lineshape analysis using this approach. Additional high temperature spectroscopy research was conducted to reduce uncertainties in the scramjet application. The lasers are optical fiber coupled to ports at the combustor exit and in the nozzle region. The output from the two diode lasers were combined in a single fiber, and the resultant two-wavelength beam was subsequently split into four legs. Each leg was directed through 60 meters of optical fiber to four combustor exit locations for measurement of beam intensity after absorption by the water within the flow. Absorption results will be compared to 1D combustor analysis using RJPA and nozzle CFD computations as well as to data from a nozzle metric

  3. Vibration monitoring/diagnostic techniques, as applied to reactor coolant pumps

    International Nuclear Information System (INIS)

    Sculthorpe, B.R.; Johnson, K.M.

    1986-01-01

    With the increased awareness of reactor coolant pump (RCP) cracked shafts, brought about by the catastrophic shaft failure at Crystal River number3, Florida Power and Light Company, in conjunction with Bently Nevada Corporation, undertook a test program at St. Lucie Nuclear Unit number2, to confirm the integrity of all four RCP pump shafts. Reactor coolant pumps play a major roll in the operation of nuclear-powered generation facilities. The time required to disassemble and physically inspect a single RCP shaft would be lengthy, monetarily costly to the utility and its customers, and cause possible unnecessary man-rem exposure to plant personnel. When properly applied, vibration instrumentation can increase unit availability/reliability, as well as provide enhanced diagnostic capability. This paper reviews monitoring benefits and diagnostic techniques applicable to RCPs/motor drives

  4. The diagnostic odds ratio: a single indicator of test performance

    NARCIS (Netherlands)

    Glas, Afina S.; Lijmer, Jeroen G.; Prins, Martin H.; Bonsel, Gouke J.; Bossuyt, Patrick M. M.

    2003-01-01

    Diagnostic testing can be used to discriminate subjects with a target disorder from subjects without it. Several indicators of diagnostic performance have been proposed, such as sensitivity and specificity. Using paired indicators can be a disadvantage in comparing the performance of competing

  5. A modern diagnostic approach for automobile systems condition monitoring

    Science.gov (United States)

    Selig, M.; Shi, Z.; Ball, A.; Schmidt, K.

    2012-05-01

    An important topic in automotive research and development is the area of active and passive safety systems. In general, it is grouped in active safety systems to prevent accidents and passive systems to reduce the impact of a crash. An example for an active system is ABS while a seat belt tensioner represents the group of passive systems. Current developments in the automotive industry try to link active with passive system components to enable a complete event sequence, beginning with the warning of the driver about a critical situation till the automatic emergency call after an accident. The cross-linking has an impact on the current diagnostic approach, which is described in this paper. Therefore, this contribution introduces a new diagnostic approach for automotive mechatronic systems. The concept is based on monitoring the messages which are exchanged via the automotive communication systems, e.g. the CAN bus. According to the authors' assumption, the messages on the bus are changing between faultless and faulty vehicle condition. The transmitted messages of the sensors and control units are different depending on the condition of the car. First experiments are carried and in addition, the hardware design of a suitable diagnostic interface is presented. Finally, first results will be presented and discussed.

  6. A modern diagnostic approach for automobile systems condition monitoring

    International Nuclear Information System (INIS)

    Selig, M; Ball, A; Shi, Z; Schmidt, K

    2012-01-01

    An important topic in automotive research and development is the area of active and passive safety systems. In general, it is grouped in active safety systems to prevent accidents and passive systems to reduce the impact of a crash. An example for an active system is ABS while a seat belt tensioner represents the group of passive systems. Current developments in the automotive industry try to link active with passive system components to enable a complete event sequence, beginning with the warning of the driver about a critical situation till the automatic emergency call after an accident. The cross-linking has an impact on the current diagnostic approach, which is described in this paper. Therefore, this contribution introduces a new diagnostic approach for automotive mechatronic systems. The concept is based on monitoring the messages which are exchanged via the automotive communication systems, e.g. the CAN bus. According to the authors' assumption, the messages on the bus are changing between faultless and faulty vehicle condition. The transmitted messages of the sensors and control units are different depending on the condition of the car. First experiments are carried and in addition, the hardware design of a suitable diagnostic interface is presented. Finally, first results will be presented and discussed.

  7. Vibration monitoring and diagnostic system developments in the VEIKI for the electric power industry

    International Nuclear Information System (INIS)

    Bessenyei, Z.

    1993-01-01

    Members of the ARGUS family comprising IBM PC-based data logging and data evaluation devices for vibration monitoring and diagnostics have been installed at WWER type nuclear reactors (in Paks, Hungary, and in Kalinin, Russia), and at some fossil fuel power plants in Hungary. The important features of the ARGUS monitoring system are discussed, and application details are presented. (N.T.) 2 figs

  8. METAL:LIC target failure diagnostics by means of liquid metal loop vibrations monitoring

    International Nuclear Information System (INIS)

    Dementjevs, S.; Barbagallo, F.; Wohlmuther, M.; Thomsen, K.; Zik, A.; Nikoluskins, R.

    2014-01-01

    A target mock-up, developed as an European Spallation Source comparative solution, (METAL:LIC) has been tested in a dedicated lead bismuth eutectic (LBE) loop in the Institute of Physics at the University of Latvia. In particular, the feasibility of diagnostic vibration monitoring has been investigated. The loop parameters were: operation temperature 300°C; tubing ∅100 mm, overall length 8 m; electromagnetic pump based on permanent magnets, flow rate 180 kg/s. With sufficient static pressure of a few bars, cavitation was avoided. The vibrations in the loop were measured and analyzed. Several vibrational characteristics of the set-up were derived including resonance frequencies and the dependence of excited vibrations on flow conditions and the pump rotation speed. A high sensitivity to obstructions in the loop has been confirmed, and several indicators for target failure diagnostics were tested and compared. A problem in the electromagnetic pump's gear box has been detected in a very early state long before it manifested itself in the operation of the loop. The vibration monitoring has been demonstrated as a sensitive and reliable probe for the target failure diagnostics. (author)

  9. Mechatronics in monitoring, simulation, and diagnostics of industrial and biological processes

    Science.gov (United States)

    Golnik, Natalia; Dobosz, Marek; Jakubowska, Małgorzata; Kościelny, Jan M.; Kujawińska, Małgorzata; Pałko, Tadeusz; Putz, Barbara; Sitnik, Robert; Wnuk, Paweł; Woźniak, Adam

    2013-10-01

    The paper describes a number of research projects of the Faculty of Mechatronics of Warsaw University of Technology in order to illustrate the use of common mechatronics and optomechatronics approach in solving multidisciplinary technical problems. Projects on sensors development, measurement and industrial control systems, multimodal data capture and advance systems for monitoring and diagnostics of industrial processes are presented and discussed.

  10. The Impact of Gas Turbine Component Leakage Fault on GPA Performance Diagnostics

    Directory of Open Access Journals (Sweden)

    E. L. Ntantis

    2016-01-01

    Full Text Available The leakage analysis is a key factor in determining energy loss from a gas turbine. Once the components assembly fails, air leakage through the opening increases resulting in a performance loss. Therefore, the performance efficiency of the engine cannot be reliably determined, without good estimates and analysis of leakage faults. Consequently, the implementation of a leakage fault within a gas turbine engine model is necessary for any performance diagnostic technique that can expand its diagnostics capabilities for more accurate predictions. This paper explores the impact of gas turbine component leakage fault on GPA (Gas Path Analysis Performance Diagnostics. The analysis is demonstrated with a test case where gas turbine performance simulation and diagnostics code TURBOMATCH is used to build a performance model of a model engine similar to Rolls-Royce Trent 500 turbofan engine, and carry out the diagnostic analysis with the presence of different component fault cases. Conclusively, to improve the reliability of the diagnostic results, a leakage fault analysis of the implemented faults is made. The diagnostic tool used to deal with the analysis of the gas turbine component implemented faults is a model-based method utilizing a non-linear GPA.

  11. Modern diagnostic systems for loose parts, vibration and leakage monitoring

    International Nuclear Information System (INIS)

    Kunze, U.

    1997-01-01

    The modern diagnostic systems for loose parts, vibration and leakage monitoring of Siemens marked improvements in signal detection, ease of operation, and the display of information. The paper gives an overview on: Loose parts monitoring system KUeS '95 - a computer-based system. The knowledge and experience about loose parts detection incorporated into this system can be characterized as ''intelligence''. Vibration monitoring system SUeS '95 - a fully automated system for early detection of changes in the vibration patterns of the reactor coolant system components and reactor pressure vessel internals. Leak detection system FLUeS - a system that detects even small leaks in steam-carrying components and very accurately determines their location. Leaks are detected on the moisture distribution in a sample air column into which the escaping steam locally diffuses. All systems described represent the latest state of technology. Nevertheless a considerable amount of operational experience can be reported. (author). 5 refs, 10 figs

  12. Malaria Laboratory Diagnostic Performance: Case studies of two ...

    African Journals Online (AJOL)

    Advantages of rapid diagnostic tests when compared with microscopy are simple to perform, fast, low ... The study was conducted to establish the performance of laboratory diagnosis of malaria in local Malawi .... Government of Malawi.

  13. Non-invasive hemoglobin monitoring.

    Science.gov (United States)

    Joseph, Bellal; Haider, Ansab; Rhee, Peter

    2016-09-01

    Technology has transformed the practice of medicine and surgery in particular over the last several decades. This change in practice has allowed diagnostic and therapeutic tests to be performed less invasively. Hemoglobin monitoring remains one of the most commonly performed diagnostic tests in the United States. Recently, non-invasive hemoglobin monitoring technology has gained popularity. The aim of this article is to review the principles of how this technology works, pros and cons, and the implications of non-invasive hemoglobin technology particularly in trauma surgery. Copyright © 2015 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  14. Magnetic resonance imaging of the wrist: Diagnostic performance statistics

    International Nuclear Information System (INIS)

    Hobby, Jonathan L.; Tom, Brian D.M.; Bearcroft, Philip W.P.; Dixon, Adrian K.

    2001-01-01

    AIM: To review the published diagnostic performance statistics for magnetic resonance imaging (MRI) of the wrist for tears of the triangular fibrocartilage complex, the intrinsic carpal ligaments, and for osteonecrosis of the carpal bones. MATERIALS AND METHODS: We used Medline and Embase to search the English language literature. Studies evaluating the diagnostic performance of MRI of the wrist in living patients with surgical confirmation of MR findings were identified. RESULTS: We identified 11 studies reporting the diagnostic performance of MRI for tears of the triangular fibrocartilage complex for a total of 410 patients, six studies for the scapho-lunate ligament (159 patients), six studies for the luno-triquetral ligament (142 patients) and four studies (56 patients) for osteonecrosis of the carpal bones. CONCLUSIONS: Magnetic resonance imaging is an accurate means of diagnosing tears of the triangular fibrocartilage and carpal osteonecrosis. Although MRI is highly specific for tears of the intrinsic carpal ligaments, its sensitivity is low. The diagnostic performance of MRI in the wrist is improved by using high-resolution T2* weighted 3D gradient echo sequences. Using current imaging techniques without intra-articular contrast medium, magnetic resonance imaging cannot reliably exclude tears of the intrinsic carpal ligaments. Hobby, J.L. (2001)

  15. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  16. 5 CFR 430.306 - Monitoring performance.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Monitoring performance. 430.306 Section 430.306 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Managing Senior Executive Performance § 430.306 Monitoring performance. (a) Supervisors must...

  17. Decentralized diagnostics based on a distributed micro-genetic algorithm for transducer networks monitoring large experimental systems.

    Science.gov (United States)

    Arpaia, P; Cimmino, P; Girone, M; La Commara, G; Maisto, D; Manna, C; Pezzetti, M

    2014-09-01

    Evolutionary approach to centralized multiple-faults diagnostics is extended to distributed transducer networks monitoring large experimental systems. Given a set of anomalies detected by the transducers, each instance of the multiple-fault problem is formulated as several parallel communicating sub-tasks running on different transducers, and thus solved one-by-one on spatially separated parallel processes. A micro-genetic algorithm merges evaluation time efficiency, arising from a small-size population distributed on parallel-synchronized processors, with the effectiveness of centralized evolutionary techniques due to optimal mix of exploitation and exploration. In this way, holistic view and effectiveness advantages of evolutionary global diagnostics are combined with reliability and efficiency benefits of distributed parallel architectures. The proposed approach was validated both (i) by simulation at CERN, on a case study of a cold box for enhancing the cryogeny diagnostics of the Large Hadron Collider, and (ii) by experiments, under the framework of the industrial research project MONDIEVOB (Building Remote Monitoring and Evolutionary Diagnostics), co-funded by EU and the company Del Bo srl, Napoli, Italy.

  18. Development and optimization of the LHC and the SPS beam diagnostics based on synchrotron radiation monitoring

    International Nuclear Information System (INIS)

    Trad, Georges

    2015-01-01

    Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams. Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments. A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing the description of an SR monitor from its source up to the detector. The simulations were confirmed by direct observations, and a detailed performance studies of the operational SR imaging monitor in the LHC, where different techniques for experimentally validating the system were applied, such as cross-calibrations with the wire scanners at low intensity (that are considered as a reference) and direct comparison with beam sizes de-convoluted from the LHC luminosity measurements. In 2015, the beam sizes to be measured with the further increase of the LHC beam energy to 7 TeV will decrease down to ∼190 μm. In these conditions, the SR imaging technique was found at its limits of applicability since the error on the beam size determination is proportional to the ratio of the system resolution and the measured beam size. Therefore, various solutions were probed to improve the system's performance such as the choice of one light polarization, the reduction of

  19. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    Science.gov (United States)

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  20. The SUCCESS model for laboratory performance and execution of rapid molecular diagnostics in patients with sepsis.

    Science.gov (United States)

    Dekmezian, Mhair; Beal, Stacy G; Damashek, Mary Jane; Benavides, Raul; Dhiman, Neelam

    2015-04-01

    Successful performance and execution of rapid diagnostics in a clinical laboratory hinges heavily on careful validation, accurate and timely communication of results, and real-time quality monitoring. Laboratories must develop strategies to integrate diagnostics with stewardship and evidence-based clinical practice guidelines. We present a collaborative SUCCESS model for execution and monitoring of rapid sepsis diagnostics to facilitate timely treatment. Six months after execution of the Verigene Gram-Positive Blood Culture (BC-GP) and the AdvanDx PNA-FISH assays, data were collected on 579 and 28 episodes of bacteremia and fungemia, respectively. Clinical testing was executed using a SUCCESS model comprising the following components: stewardship, utilization of resources, core strategies, concierge services, education, support, and surveillance. Stewardship needs were identified by evaluating the specialty services benefiting from new testing. Utilization of resources was optimized by reviewing current treatment strategies and antibiogram and formulary options. Core strategies consisted of input from infectious disease leadership, pharmacy, and laboratory staff. Concierge services included automated Micro-eUpdate and physician-friendly actionable reports. Education modules were user-specific, and support was provided through a dedicated 24/7 microbiology hotline. Surveillance was performed by daily audit by the director. Using the SUCCESS model, the turnaround time for the detailed report with actionable guidelines to the physician was ∼3 hours from the time of culture positivity. The overall correlation between rapid methods and culture was 94% (546/579). Discrepant results were predominantly contaminants such as a coagulase-negative staphylococci or viridans streptococci in mixed cultures. SUCCESS is a cost-effective and easily adaptable model for clinical laboratories with limited stewardship resources.

  1. The Influence of Time Pressure and Case Complexity on Physicians׳ Diagnostic Performance

    Directory of Open Access Journals (Sweden)

    Dalal A. ALQahtani

    2016-12-01

    Conclusions: Time pressure did not impact the diagnostic performance, whereas the complexity of the clinical case negatively influenced the diagnostic accuracy. Further studies with the enhanced experimental manipulation of time pressure are needed to reveal the effect of time pressure, if any, on a physician׳s diagnostic performance.

  2. Comparative guide to emerging diagnostic tools for large commercial HVAC systems

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Hannah; Piette, Mary Ann

    2001-05-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

  3. Heat exchanger performance monitoring guidelines

    International Nuclear Information System (INIS)

    Stambaugh, N.; Closser, W. Jr.; Mollerus, F.J.

    1991-12-01

    Fouling can occur in many heat exchanger applications in a way that impedes heat transfer and fluid flow and reduces the heat transfer or performance capability of the heat exchanger. Fouling may be significant for heat exchanger surfaces and flow paths in contact with plant service water. This report presents guidelines for performance monitoring of heat exchangers subject to fouling. Guidelines include selection of heat exchangers to monitor based on system function, safety function and system configuration. Five monitoring methods are discussed: the heat transfer, temperature monitoring, temperature effectiveness, delta P and periodic maintenance methods. Guidelines are included for selecting the appropriate monitoring methods and for implementing the selected methods. The report also includes a bibliography, example calculations, and technical notes applicable to the heat transfer method

  4. Diagnostic Performance of the Intraoral Radiographs on the Interproximal Dental Caries

    International Nuclear Information System (INIS)

    Kim, Soo Ji; Kang, Byung Cheol

    1998-01-01

    The purpose of this study was to evaluated the diagnostic performance of the senior dental students for the proximal dental caries in intraoral radiographs and to compare it with the dental hospital residents, the reference group. It was also investigated the diagnostic performance according to the carious lesion depth. Thirty-five intraoral periapical and bitewing radiographs with 213 proximal surface included in this study were selected from the dental patients at Chonnam National University Hospital. The observers were 181 senior dental students from 5 dental schools and 40 dentists who were second year resident from 5 dental hospitals. They were asked to evaluate the presence ro the absence of the proximal dental caries. The results were as follows : 1. The mean of the hitting rate for the overall observers was 184.51 surfaces and the diagnostic accuracy was 86.62%. 2. The diagnostic performance of the sound proximal tooth surfaces was very high, i.e., 91.5% true negative rate and 8.5% false positive rate. 3. The diagnostic performance of the dentist group was higher than the student group (P 0.001).

  5. Neuropharmacology of performance monitoring.

    Science.gov (United States)

    Jocham, Gerhard; Ullsperger, Markus

    2009-01-01

    Adaptive, goal-directed behavior requires that organisms evaluate their actions in terms of their outcomes. Neuroimaging studies show that unfavorable outcomes or situations with high level of conflict engage the posterior medial frontal cortex (pMFC). Recording of event-related potentials revealed that these situations are accompanied by a negative deflection, the so-called error-related negativity (ERN), which appears after an erroneous response or after negative feedback. Both activation of the pMFC and the ERN are thought to represent a signal that indicates the need for behavioral adjustment, and to recruit other brain regions that implement these adjustments. While many fMRI and EEG studies have shed light on the anatomical structures and the cognitive processes involved in performance monitoring, only very recently have researchers begun to investigate the underlying neurochemical mechanisms. Drawing on the putative involvement of dopamine (DA) neurons in coding a reward prediction error, an influential theory has ascribed a pivotal role to DA in performance monitoring. However, although important, DA is certainly not the only neuromodulator involved. Recent studies point to a role for serotonin, norepinephrine and GABA, but also for adenosine in performance monitoring. Here, we review the evidence for neurotransmitter effects on this function in humans. In this light, we critically discuss currently debated models of performance monitoring and potential alternatives.

  6. Sensor Selection for Aircraft Engine Performance Estimation and Gas Path Fault Diagnostics

    Science.gov (United States)

    Simon, Donald L.; Rinehart, Aidan W.

    2016-01-01

    This paper presents analytical techniques for aiding system designers in making aircraft engine health management sensor selection decisions. The presented techniques, which are based on linear estimation and probability theory, are tailored for gas turbine engine performance estimation and gas path fault diagnostics applications. They enable quantification of the performance estimation and diagnostic accuracy offered by different candidate sensor suites. For performance estimation, sensor selection metrics are presented for two types of estimators including a Kalman filter and a maximum a posteriori estimator. For each type of performance estimator, sensor selection is based on minimizing the theoretical sum of squared estimation errors in health parameters representing performance deterioration in the major rotating modules of the engine. For gas path fault diagnostics, the sensor selection metric is set up to maximize correct classification rate for a diagnostic strategy that performs fault classification by identifying the fault type that most closely matches the observed measurement signature in a weighted least squares sense. Results from the application of the sensor selection metrics to a linear engine model are presented and discussed. Given a baseline sensor suite and a candidate list of optional sensors, an exhaustive search is performed to determine the optimal sensor suites for performance estimation and fault diagnostics. For any given sensor suite, Monte Carlo simulation results are found to exhibit good agreement with theoretical predictions of estimation and diagnostic accuracies.

  7. Methodology for quantitative evaluation of diagnostic performance

    International Nuclear Information System (INIS)

    Metz, C.

    1981-01-01

    Of various approaches that might be taken to the diagnostic performance evaluation problem, Receiver Operating Characteristic (ROC) analysis holds great promise. Further development of the methodology for a unified, objective, and meaningful approach to evaluating the usefulness of medical imaging procedures is done by consideration of statistical significance testing, optimal sequencing of correlated studies, and analysis of observer performance

  8. Implementation of an occupational monitoring program in diagnostic radiology at the 'Hospital Universitario Clementino Fraga Filho'

    International Nuclear Information System (INIS)

    Oliveira, Sergio Ricardo de; Carvalho, Antonio Carlos Pires; Azevedo, Ana Cecilia Pedrosa de

    2003-01-01

    An occupational monitoring program in diagnostic radiology was implemented at the Hospital Clementino Fraga Filho of the Rio de Janeiro Federal University (UFRJ), Brazil, in accordance with the Brazilian legislation. Previously, a survey of all personnel involved with ionizing radiation was performed. Many problems were observed: the great majority of the workers were not properly monitored; only three departments of the hospital kept an independent survey of the occupational doses; there was not a follow-up control of the high doses. With the implementation of the program, a new laboratory was chosen to read the dosemeters and this initiative resulted in reduction of the hospital costs. The inclusion of seven more departments in the program represented an increase of 60% in the number of monitored workers. The program also provided a system to control the high doses, especially in the Hemodynamics department, which presented the highest mean dose value (0.32 mSv/month). An area survey program was performed during different periods in places considered of high risk for the workers and for the public as well. At the same time, a software was used to build a database with the aim of controlling all personnel data. The implementation of the program provided all personnel involved a better knowledge of the risks associated with ionizing radiation and of radioprotection, and also awareness of the need of correct use of the personal dose monitors. (author)

  9. Performance monitoring of safeguards equipment

    International Nuclear Information System (INIS)

    Sirisena, K.; Peltoranta, M.; Goussarov, V.; Vodrazka, P.

    1999-01-01

    SGTCS is responsible for monitoring and reporting the performance of the SG equipment. Performance monitoring (PM) has been implemented in most important safeguards equipment operating unattended in nuclear facilities. Inspectors acquire equipment performance data in facilities. After inspection, the data package is submitted to SGTCS for processing and analysis. The performance data is used for identification of systems or components, which should be changed in the field and for identification of modules which, should be diagnosed at HQ in order to determine the cause of failure. Moreover, the performance data is used for preventive maintenance and spares distribution planning, and to provide statistics for official reports and management decision making. An important part of the performance monitoring is reporting. Equipment performance reports contain information about equipment inventory, utilization, failure types, failure distribution, and reliability. Trends in performance are given in graphical form in cases, where past data is available. Reliability estimates such as expected times between failures are provided. The automated reporting tools are obtainable through EMIS database application. (author)

  10. Diagnostic suite neuro-fuzzy in an advanced alarm monitoring and predictive diagnostic system for rotating machinery

    International Nuclear Information System (INIS)

    Geruzzi, P.

    1999-01-01

    The 'Foxboro SCADA', former 'Automation Systems Division' of Nuovo Pignone, at the end of eighty years, has been involved in the development of a flexible and powerful Diagnostic System for Rotating Machinery designed and manufactured in other divisions of the Company. This system amalgamates, in a single computer, all the functionality nowadays necessary to correctly manage locally and remotely the Evolutionary Maintenance of rotating machines as well as the relevant plants. It's specially designed to plan preventive and emergency maintenance procedures and to help the maintenance staff/service in preventing the occurrence of failures or severe damage to complete turbo-machinery plant including turbine, compressor and other machines. The system is designed to supervise and to analyze the operating state of one or more turbo- machinery units such as turbo-compressors, turbo-generators and turbo-pumps giving an effective support to plan preventive and breakdown maintenance monitoring the performances of each turbo-group's element and analyzing a large number of thermodynamic and mechanical parameters related to high pressure turbines, low pressure turbines, combustion chambers, axial compressors and load (compressors, generators, and pumps). A brief presentation of the system is provided (author) (ml)

  11. Resilient actions in the diagnostic process and system performance.

    Science.gov (United States)

    Smith, Michael W; Davis Giardina, Traber; Murphy, Daniel R; Laxmisan, Archana; Singh, Hardeep

    2013-12-01

    Systemic issues can adversely affect the diagnostic process. Many system-related barriers can be masked by 'resilient' actions of frontline providers (ie, actions supporting the safe delivery of care in the presence of pressures that the system cannot readily adapt to). We explored system barriers and resilient actions of primary care providers (PCPs) in the diagnostic evaluation of cancer. We conducted a secondary data analysis of interviews of PCPs involved in diagnostic evaluation of 29 lung and colorectal cancer cases. Cases covered a range of diagnostic timeliness and were analysed to identify barriers for rapid diagnostic evaluation, and PCPs' actions involving elements of resilience addressing those barriers. We rated these actions according to whether they were usual or extraordinary for typical PCP work. Resilient actions and associated barriers were found in 59% of the cases, in all ranges of timeliness, with 40% involving actions rated as beyond typical. Most of the barriers were related to access to specialty services and coordination with patients. Many of the resilient actions involved using additional communication channels to solicit cooperation from other participants in the diagnostic process. Diagnostic evaluation of cancer involves several resilient actions by PCPs targeted at system deficiencies. PCPs' actions can sometimes mitigate system barriers to diagnosis, and thereby impact the sensitivity of 'downstream' measures (eg, delays) in detecting barriers. While resilient actions might enable providers to mitigate system deficiencies in the short run, they can be resource intensive and potentially unsustainable. They complement, rather than substitute for, structural remedies to improve system performance. Measures to detect and fix system performance issues targeted by these resilient actions could facilitate diagnostic safety.

  12. Development of a real time chemistry monitoring and diagnostic system

    International Nuclear Information System (INIS)

    Gaudreau, T.M.; Millett, P.J.; Bates, J.; Burns, G.

    1998-01-01

    EPRI has developed SMART chem WORKS, which is capable of operating as a real time chemistry diagnostic and monitoring system. A high degree of plant-specific customization is possible which allows discrimination between normal chemistry and off-normal conditions. The initial implementation of the system has been very successful. State of the art technology has been employed which allows remote administration of the system, a flexible, web page display of the output from the system and instant notification of excursions using email and pagers. The second installation of SMART chem WORKS is currently underway at a BWR plant, Grand Gulf. The SMART chem WORKS techniques can be applied to monitor PWR Primary Chemistry, PWR Secondary Chemistry and BWR steam cycle chemistry. A fossil steam cycle simulator will also be developed for application to fossil plants. (J.P.N.)

  13. Effect of radiologists' diagnostic work-up volume on interpretive performance.

    Science.gov (United States)

    Buist, Diana S M; Anderson, Melissa L; Smith, Robert A; Carney, Patricia A; Miglioretti, Diana L; Monsees, Barbara S; Sickles, Edward A; Taplin, Stephen H; Geller, Berta M; Yankaskas, Bonnie C; Onega, Tracy L

    2014-11-01

    To examine radiologists' screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. In an institutional review board-approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [ FPR false-positive rate ], and cancer detection rate [ CDR cancer detection rate ]). Logistic regression was used to assess the association between the volume of recalled screening mammograms ("own" mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and "any" mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0-50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0-50 mammograms, 32% performed the work-up for 51-125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPR false-positive rate (P = .004), and CDR cancer detection rate (P women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant

  14. Effect of Radiologists’ Diagnostic Work-up Volume on Interpretive Performance

    Science.gov (United States)

    Anderson, Melissa L.; Smith, Robert A.; Carney, Patricia A.; Miglioretti, Diana L.; Monsees, Barbara S.; Sickles, Edward A.; Taplin, Stephen H.; Geller, Berta M.; Yankaskas, Bonnie C.; Onega, Tracy L.

    2014-01-01

    Purpose To examine radiologists’ screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. Materials and Methods In an institutional review board–approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [FPRfalse-positive rate], and cancer detection rate [CDRcancer detection rate]). Logistic regression was used to assess the association between the volume of recalled screening mammograms (“own” mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and “any” mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Results Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0–50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0–50 mammograms, 32% performed the work-up for 51–125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPRfalse-positive rate (P = .004), and CDRcancer detection rate (P work-ups for any radiologist yielded significant increases in FPRfalse-positive rate (P = .011) and CDRcancer detection rate (P

  15. Thermal performance monitoring and optimisation

    International Nuclear Information System (INIS)

    Sunde, Svein; Berg; Oeyvind

    1998-01-01

    Monitoring of the thermal efficiency of nuclear power plants is expected to become increasingly important as energy-market liberalisation exposes plants to increasing availability requirements and fiercer competition. The general goal in thermal performance monitoring is straightforward: to maximise the ratio of profit to cost under the constraints of safe operation. One may perceive this goal to be pursued in two ways, one oriented towards fault detection and cost-optimal predictive maintenance, and another determined at optimising target values of parameters in response to any component degradation detected, changes in ambient conditions, or the like. Annual savings associated with effective thermal-performance monitoring are expected to be in the order of $ 100 000 for power plants of representative size. A literature review shows that a number of computer systems for thermal-performance monitoring exists, either as prototypes or commercially available. The characteristics and needs of power plants may vary widely, however, and decisions concerning the exact scope, content and configuration of a thermal-performance monitor may well follow a heuristic approach. Furthermore, re-use of existing software modules may be desirable. Therefore, we suggest here the design of a flexible workbench for easy assembly of an experimental thermal-performance monitor at the Halden Project. The suggested design draws heavily on our extended experience in implementing control-room systems featured by assets like high levels of customisation, flexibility in configuration and modularity in structure, and on a number of relevant adjoining activities. The design includes a multi-computer communication system and a graphical user's interface, and aims at a system adaptable to any combination of in-house or end user's modules, as well as commercially available software. (author)

  16. Handbook of technical diagnostics fundamentals and application to structures and systems

    CERN Document Server

    2013-01-01

    This book presents concepts, methods and techniques to examine symptoms of faults and failures of structures, systems and components and to monitor functional performance and structural integrity. The book is organized in five parts. Part A introduces the scope and application of technical diagnostics and gives a comprehensive overview of the physics of failure. Part B presents all relevant methods and techniques for diagnostics and monitoring: from stress, strain, vibration analysis, nondestructive evaluation, thermography and industrial radiology to computed tomography and subsurface microstructural analysis. Part C cores the principles and concepts of technical failure analysis, illustrates case studies, and outlines machinery diagnostics with an emphasis on tribological systems. Part D describes the application of structural health monitoring and performance control to plants and the technical infrastructure, including buildings, bridges, pipelines, electric power stations, offshore wind structures, and r...

  17. Comparative guide to emerging diagnostic tools for large commercial HVAC systems; TOPICAL

    International Nuclear Information System (INIS)

    Friedman, Hannah; Piette, Mary Ann

    2001-01-01

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool

  18. Some aspects of diagnostic systems perspective

    International Nuclear Information System (INIS)

    Korosec, D.

    1998-01-01

    The integrity and safety of all nuclear power plant systems and components is guaranteed by the high requirements to quality assurance during all phases of design, fabrication, construction and operation. Many of the countries operating nuclear facilities, introduced advanced, sophisticated diagnostic systems for continuous monitoring safety important process parameters. The licensee should perform an assessment of the existing diagnostic systems, often supplied by the original design, their reliability and the need for the introduction of the additional monitoring/diagnostic systems. The operating experience should be taken into account and the assessment of the further needs. On this field has to be made on the results of PSA studies. In addition to the cost benefit analysis the evaluation of the new diagnostic systems in the light of nuclear safety should be also made. Experience, gained from the utilities, which have already installed this kind of the equipment should be very useful. Introducing new diagnostic systems will require often a safety assessment of the necessary modifications. Licensing process should be based on the existing nuclear legislation with certain additional requirements. (author)

  19. Expanding the Operational Limits of the Single-Point Impedance Diagnostic for Internal Temperature Monitoring of Lithium-ion Batteries

    International Nuclear Information System (INIS)

    Spinner, Neil S.; Love, Corey T.; Rose-Pehrsson, Susan L.; Tuttle, Steven G.

    2015-01-01

    Highlights: • Single-point impedance diagnostic technique demonstrated for lithium-ion batteries • Correlation between imaginary impedance and internal temperature determined • Instantaneous monitoring of commercial lithium-ion battery internal temperature • Expanded temperature range from −10°C up to 95°C • Non-invasive method useful for practical temperature monitoring of commercial cells - Abstract: Instantaneous internal temperature monitoring of a commercial 18650 LiCoO 2 lithium-ion battery was performed using a single-point EIS measurement. A correlation between the imaginary impedance, –Z imag , and internal temperature at 300 Hz was developed that was independent of the battery’s state of charge. An Arrhenius-type dependence was applied, and the activation energy for SEI ionic conductivity was found to be 0.13 eV. Two separate temperature-time experiments were conducted with different sequences of temperature, and single-point impedance tests at 300 Hz were performed to validate the correlation. Limitations were observed with the upper temperature range (68°C < T < 95°C), and consequently a secondary, empirical fit was applied for this upper range to improve accuracy. Average differences between actual and fit temperatures decreased around 3-7°C for the upper range with the secondary correlation. The impedance response at this frequency corresponded to the anode/SEI layer, and the SEI is reported to be thermally stable up to around 100°C, at which point decomposition may occur leading to battery deactivation and/or total failure. It is therefore of great importance to be able to track internal battery temperatures up to this critical point of 100°C, and this work demonstrates an expansion of the single-point EIS diagnostic to these elevated temperatures

  20. Development of a reactor coolant pump monitoring and diagnostic system. Progress report, June 1982-July 1983

    International Nuclear Information System (INIS)

    Morris, D.J.; Sommerfield, G.A.

    1983-12-01

    The quality of operating data has been insufficient to allow proper evaluation of theoretical reactor coolant (RC) pump seal failure mechanisms. The RC pump monitoring and diagnostic system being developed and installed at Toledo Edison's Davis-Besse Nuclear Power Station will examine the relationship between seal failures and three other variables: The rotordynamic behavior of the pump shaft and related components, the internal conditions and performance of the seals, and the plant or pump operating environment (controlled by the plant operator). Interrelationships between these areas will be developed during the data collection task, scheduled to begin in October 1983 (for a full fuel cycle at Davis-Besse). This report describes system software and hardware development, testing, and installation work performed during this period. Also described is a parallel effort being conducted by a B and W/Byron Jackson/Utility group to improve pump seal performance

  1. Diagnostics monitor of the braking efficiency in the on board diagnostics system for the motor vehicles

    Science.gov (United States)

    Gajek, Andrzej

    2016-09-01

    The article presents diagnostics monitor for control of the efficiency of brakes in various road conditions in cars equipped with pressure sensor in brake (ESP) system. Now the brake efficiency of the vehicles is estimated periodically in the stand conditions on the base of brake forces measurement or in the road conditions on the base of the brake deceleration. The presented method allows to complete the stand - periodical tests of the brakes by current on board diagnostics system OBD for brakes. First part of the article presents theoretical dependences between deceleration of the vehicle and brake pressure. The influence of the vehicle mass, initial speed of braking, temperature of brakes, aerodynamic drag, rolling resistance, engine resistance, state of the road surface, angle of the road sloping on the deceleration have been analysed. The manner of the appointed of these parameters has been analysed. The results of the initial investigation have been presented. At the end of the article the strategy of the estimation and signalization of the irregular value of the deceleration are presented.

  2. Advanced Light Source beam diagnostics systems

    International Nuclear Information System (INIS)

    Hinkson, J.

    1993-10-01

    The Advanced Light Source (ALS), a third-generation synchrotron light source, has been recently commissioned. Beam diagnostics were very important to the success of the operation. Each diagnostic system is described in this paper along with detailed discussion of its performance. Some of the systems have been in operation for two years. Others, in the storage ring, have not yet been fully commissioned. These systems were, however, working well enough to provide the essential information needed to store beam. The devices described in this paper include wall current monitors, a beam charge monitor, a 50 ohm Faraday cup, DC current transformers, broad-hand striplines, fluorescence screens, beam collimators and scrapers, and beam position monitors. Also, the means by which waveforms are digitized and displayed in the control room is discussed

  3. Assessment of Augmented Electronic Fuel Controls for Modular Engine Diagnostics and Condition Monitoring

    Science.gov (United States)

    1978-12-01

    removal of the horoscope . Diagnostic Conoctor - E4 Th10 E4 23-pin connoctor on the electrical control unit Is provided for ground- checking electrical...confidenou in engine condition monitoring * 1min general. Thi9 has boon especially true in~ eases where fUse signal s have c~aused engine shutdowns. Where ECWI

  4. Quantitative performance monitoring

    International Nuclear Information System (INIS)

    Heller, A.S.

    1987-01-01

    In the recently published update of NUREG/CR 3883, it was shown that Japanese plants of size and design similar to those in the US have significantly fewer trips in a given year of operation. One way to reduce such imbalance is the efficient use of available plant data. Since plant data are recorded and monitored continuously for management feedback and timely resolution of problems, this data should be actively used to increase the efficiency of operations and, ultimately, for a reduction of plant trips in power plants. A great deal of information is lost, however, if the analytical tools available for the data evaluation are misapplied or not adopted at all. This paper deals with a program developed to use quantitative techniques to monitor personnel performance in an operating power plant. Visual comparisons of ongoing performance with predetermined quantitative performance goals are made. A continuous feedback is provided to management for early detection of adverse trends and timely resolution of problems. Ultimately, costs are reduced through effective resource management and timely decision making

  5. Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.

    Science.gov (United States)

    Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David

    1989-05-01

    The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.

  6. Study for the design method of multi-agent diagnostic system to improve diagnostic performance for similar abnormality

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents on industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning such as support vector machine is expected to detect the occurrence of abnormality in a plant early and correctly. There were reported that these diagnostic machines has high accuracy to diagnose the operating state of industrial plant under mono abnormality occurrence. But the each diagnostic machine on the multi-agent diagnostic system may misdiagnose similar abnormalities as a same abnormality if abnormalities to diagnose increases. That causes that a single diagnostic machine may show higher diagnostic performance than one of multi-agent diagnostic system because decision-making considering with misdiagnosis is difficult. Therefore, we study the design method for multi-agent diagnostic system to diagnose similar abnormality correctly. This method aimed to realize automatic generation of diagnostic system where the generation process and location of diagnostic machines are optimized to diagnose correctly the similar abnormalities which are evaluated from the similarity of process signals by statistical method. This paper explains our design method and reports the result evaluated our method applied to the process data of the fast-breeder reactor Monju

  7. Vibration monitoring and fault diagnostics of a thermal power plant

    International Nuclear Information System (INIS)

    Hafeez, T.; Ghani, R.; Chohan, G.Y.; Amir, M.

    2003-01-01

    A thermal power plant was monitored from HP-turbine to the generator end. The vibration data at different plant locations was obtained with the help of a data collector/analyzer. The spectra of-all locations generate the symptoms for different problems of moderate and high vibration levels like bent shaft, misalignment in the exciter rotor and three couplings, mechanical looseness on generator and exciter sides. The possible causes of these faults are discussed on the basis of presented vibration spectra in this paper. The faults were later on rectified on the basis of this diagnostics. (author)

  8. Early evaluation of a second generation information monitoring and diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Kinney, Satkartar; Bourassa, Norman; Xu, Peng; Haves, Philip; Kinney, Kristopher; Shockman, Christine

    2002-03-25

    Private sector commercial office buildings are challenging environments for energy efficiency projects. This challenge is related to the complexity of business environments that involve ownership, operation, and tenant relationships. Whether it is poor quality design, inefficient operations, degradation of equipment over time, or merely the increasing use of energy by tenants and inattention from landlords, commercial office building energy use continues to increase. This research project was developed to examine the environment for building operations and identify causes of inefficient use of energy related to technical and organizational issues. This report discusses a second-generation Information Monitoring and Diagnostic System (IMDS) installed at a leased office building in Sacramento, California. The report begins with a brief summary of the IMDS research at the previous building, followed by a discussion of the building selection process, the IMDS design and installation, recent use of the IMDS, costs and benefits, and fault detection and diagnostic research using the IMDS. A web site describes the IMDS in detail (see imds.lbl.gov). The underlying principle of this research project is that high quality building performance data can help show where energy is being used and how buildings systems actually perform is an important first step toward improving building energy efficiency. The project utilizes a high-quality monitoring system that has been developed during the past decade by a partnership between LBNL and private industry. This research project has been successful in demonstrating that the IMDS is tremendously valuable to the building operators at the Sacramento site. The building operators not only accept the technology, but it has become the core of their day-to-day building control concepts. The innovative property management company, Jones Lang LaSalle, is interested in installing more sites to determine if the system could provide an economic

  9. 30 CFR 250.520 - When do I have to perform a casing diagnostic test?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When do I have to perform a casing diagnostic... Operations Casing Pressure Management § 250.520 When do I have to perform a casing diagnostic test? (a) You must perform a casing diagnostic test within 30 days after first observing or imposing casing pressure...

  10. Model of critical diagnostic reasoning: achieving expert clinician performance.

    Science.gov (United States)

    Harjai, Prashant Kumar; Tiwari, Ruby

    2009-01-01

    Diagnostic reasoning refers to the analytical processes used to determine patient health problems. While the education curriculum and health care system focus on training nurse clinicians to accurately recognize and rescue clinical situations, assessments of non-expert nurses have yielded less than satisfactory data on diagnostic competency. The contrast between the expert and non-expert nurse clinician raises the important question of how differences in thinking may contribute to a large divergence in accurate diagnostic reasoning. This article recognizes superior organization of one's knowledge base, using prototypes, and quick retrieval of pertinent information, using similarity recognition as two reasons for the expert's superior diagnostic performance. A model of critical diagnostic reasoning, using prototypes and similarity recognition, is proposed and elucidated using case studies. This model serves as a starting point toward bridging the gap between clinical data and accurate problem identification, verification, and management while providing a structure for a knowledge exchange between expert and non-expert clinicians.

  11. Thyroid Ultrasound: Change of Inter-observer Variability and Diagnostic Performance after Training

    International Nuclear Information System (INIS)

    Moon, Hee Jung; Kim, Eun Kyung; Kwak, Jin Young; Park, Jeong Seon

    2011-01-01

    To investigate and compare inter-observer variability and diagnostic performance of thyroid ultrasound (US) between a faculty member and observing residents. From October 2007 to June 2009, 18 residents underwent training in thyroid US section. Group 1 included 8 residents that were trained for the first time and group 2 included 10 residents that were trained for the second time. US features of nodules were recorded according to the composition, echogenicity, margin, calcifications, shape, and final assessment by a faculty member and residents, respectively. Following a discussion, a faculty member performed fine needle aspiration. Then, the inter-observer variability and diagnostic performance between a faculty member and residents were investigated and compared for US. In group 1, agreement for composition in resident 1, calcification for residents 5 and 6, and shape for resident 4 were slight, moderate, moderate, and moderate, respectively. In group 2, agreement for composition in residents 1 and 10 were moderate. Substantial or greater agreement was observed more frequently in group 2 than 1. The diagnostic performances for both the faculty and residents were high and not statistically different. Agreement for US features between a faculty and residents as well as diagnostic performance were high. Moreover, diagnostic performance of residents that underwent training a second time of training was higher than residents that underwent training only once

  12. Operational performance of generator condition monitors

    International Nuclear Information System (INIS)

    Braun, J.M.; Brown, G.

    1990-01-01

    This paper reports on the generator condition monitor (GCM) developed in an attempt to detect overheating inside large turbine generators. As part of a broader study on rotating machinery diagnostics, generator condition monitors were evaluated under field conditions in a 550 MW turbogenerator. Small 100 W resistors coated with insulating paints and varnishes were mounted inside the generator to simulate insulation overheating. The GCM responded very rapidly to an overheating event, typically within two minutes, even for hot spots as small s 10 cm 2 . Similarly the aerosols produced on overheating were found extremely short lived, decaying within two to three minutes after overheating was discontinued. Use of heated ion chambers was found to desensitize the GCM regardless of the nature of the overheated insulation and in some cases would altogether prevent the GCM from reaching the 50% pre-set alarm level commonly used on GCMs

  13. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G.; Salapura, Valentina

    2012-07-24

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  14. Possible use of CdTe detectors in kVp monitoring of diagnostic X-ray tubes

    International Nuclear Information System (INIS)

    Krmar, M.; Bucalovic, N.; Baucal, M.; Jovancevic, N.

    2010-01-01

    It has been suggested that kVp of diagnostic X-ray devices (or maximal energy of X-ray photon spectra) should be monitored routinely; however a standardized non-invasive technique has yet to be developed and proposed. It is well known that the integral number of Compton scattered photons and the intensities of fluorescent X-ray lines registered after irradiation of some material by an X-ray beam are a function of the maximal beam energy. CdTe detectors have sufficient energy resolution to distinguish individual X-ray fluorescence lines and high efficiency for the photon energies in the diagnostic region. Our initial measurements have demonstrated that the different ratios of the integral number of Compton scattered photons and intensities of K and L fluorescent lines detected by CdTe detector are sensitive function of maximal photon energy and could be successfully applied for kVp monitoring.

  15. Real-time performance monitoring and management system

    Science.gov (United States)

    Budhraja, Vikram S [Los Angeles, CA; Dyer, James D [La Mirada, CA; Martinez Morales, Carlos A [Upland, CA

    2007-06-19

    A real-time performance monitoring system for monitoring an electric power grid. The electric power grid has a plurality of grid portions, each grid portion corresponding to one of a plurality of control areas. The real-time performance monitoring system includes a monitor computer for monitoring at least one of reliability metrics, generation metrics, transmission metrics, suppliers metrics, grid infrastructure security metrics, and markets metrics for the electric power grid. The data for metrics being monitored by the monitor computer are stored in a data base, and a visualization of the metrics is displayed on at least one display computer having a monitor. The at least one display computer in one said control area enables an operator to monitor the grid portion corresponding to a different said control area.

  16. Development of GEM detector for plasma diagnostics application: simulations addressing optimization of its performance

    Science.gov (United States)

    Chernyshova, M.; Malinowski, K.; Kowalska-Strzęciwilk, E.; Czarski, T.; Linczuk, P.; Wojeński, A.; Krawczyk, R. D.

    2017-12-01

    The advanced Soft X-ray (SXR) diagnostics setup devoted to studies of the SXR plasma emissivity is at the moment a highly relevant and important for ITER/DEMO application. Especially focusing on the energy range of tungsten emission lines, as plasma contamination by W and its transport in the plasma must be understood and monitored for W plasma-facing material. The Gas Electron Multiplier, with a spatial and energy-resolved photon detecting chamber, based SXR radiation detection system under development by our group may become such a diagnostic setup considering and solving many physical, technical and technological aspects. This work presents the results of simulations aimed to optimize a design of the detector's internal chamber and its performance. The study of the effect of electrodes alignment allowed choosing the gap distances which maximizes electron transmission and choosing the optimal magnitudes of the applied electric fields. Finally, the optimal readout structure design was identified suitable to collect a total formed charge effectively, basing on the range of the simulated electron cloud at the readout plane which was in the order of ~ 2 mm.

  17. Statistical evaluation of diagnostic performance topics in ROC analysis

    CERN Document Server

    Zou, Kelly H; Bandos, Andriy I; Ohno-Machado, Lucila; Rockette, Howard E

    2016-01-01

    Statistical evaluation of diagnostic performance in general and Receiver Operating Characteristic (ROC) analysis in particular are important for assessing the performance of medical tests and statistical classifiers, as well as for evaluating predictive models or algorithms. This book presents innovative approaches in ROC analysis, which are relevant to a wide variety of applications, including medical imaging, cancer research, epidemiology, and bioinformatics. Statistical Evaluation of Diagnostic Performance: Topics in ROC Analysis covers areas including monotone-transformation techniques in parametric ROC analysis, ROC methods for combined and pooled biomarkers, Bayesian hierarchical transformation models, sequential designs and inferences in the ROC setting, predictive modeling, multireader ROC analysis, and free-response ROC (FROC) methodology. The book is suitable for graduate-level students and researchers in statistics, biostatistics, epidemiology, public health, biomedical engineering, radiology, medi...

  18. Piezo-sensor self-diagnostics using electrical impedance measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Park, G. H. (Gyu Hae); Farrar, C. R. (Charles R.); Rutherford, A. C. (Amanda C.); Robertson, A. N. (Amy N.)

    2004-01-01

    This paper present the piezoelectric sensor self-diagnostic procedure that performs in-situ monitoring of the operational status of piezoelectric materials (PZT) used for sensors and actuators in structural health monitoring (SHM) applications. The use of active-sensing piezoelectric materials has received considerable attention in the SHM community. A critical aspect of the piezoelectric active-sensing technologies is that usually large numbers of distributed sensors and actuators are needed to perform the required monitoring process. The sensor/actuator self-diagnostic procedure, where the sensors/actuators are confirmed to be functioning properly during operation, is therefore a critical component to successfully complete the SHM process and to minimize the false indication regarding the structural health. The basis of this procedure is to track the changes in the capacitive value of piezoelectric materials resulting from the sensor failure, which is manifested in the imaginary part of the measured electrical admittances. Furthermore, through the analytical and experimental investigation, it is confirmed that the bonding layer between the PZT and a host structure significantly contributes to the measured capacitive values. Therefore, by monitoring the imaginary part of the admittances, one can quantitatively assess the degradation of the mechanical/electrical properties of the PZT and its attachment to a host structure. This paper concludes with an experimental example to demonstrate the feasibility of the proposed sensor-diagnostic procedure.

  19. Expert System for Diagnostics and Status Monitoring of NPP Water Chemistry Condition

    International Nuclear Information System (INIS)

    Shvedova, M.N.; Kritski, V.G.; Zakharova, S.V.; Nikolaev, F.V.; Benediktov, V.B.

    2002-01-01

    Water chemistry condition (WCC) has been the subject of constant study and improvement up to the present day. It is connected with the presence of a direct relationship between the violation of water chemistry regulation on the one hand and components reliability of the circuit's equipment and cost-effectiveness of their operation on the other. It dictates the necessity to apply different optimization methods in the field of monitoring and use of information - analytical and diagnostic systems to assess WCC quality, control and support. By now NPP experts have broad experience in revealing and removing the causes of WCC disturbances. However this knowledge is often of an intuitive, non-classified nature, scattered among various working documents, which makes their transfer difficult. Based on what has been mentioned above, special attention is currently being paid to the problem of creating expert diagnostic systems for supporting the optimum WCC. The existing developments in this field (DIWA, Smart chem Works, the water quality control system at the Onagava NPP etc. [1,3,4,5] are based on wide use of experts' knowledge. Such expert diagnostic systems for supporting WCC refer to the new generation of intellectual control methods, which allow the incorporation of the latest achievements both in the field of water chemistry simulation and in the field of artificial intelligence and computer technologies. LI 'VNIPIET' employees have, for several years, been developing an expert diagnostic system for supporting WCC and status monitoring of RBMK - reactor NPPs [2]. This system has not only conveniently organized the traditional functions of information acquisition and storage, a complete presentation of information in the form of tables, graphs of a dynamical changes of parameters and formation regular reports, diagnostic functions and issuing recommendations on WCC correction, but it also allows the assessment of confidence in the diagnosis made, relying on a wide

  20. Plan for Demonstration of Online Monitoring for the Light Water Reactor Sustainability Online Monitoring Project

    Energy Technology Data Exchange (ETDEWEB)

    Magdy S. Tawfik; Vivek Agarwal; Nancy J. Lybeck

    2011-09-01

    Condition based online monitoring technologies and development of diagnostic and prognostic methodologies have drawn tremendous interest in the nuclear industry. It has become important to identify and resolve problems with structures, systems, and components (SSCs) to ensure plant safety, efficiency, and immunity to accidents in the aging fleet of reactors. The Machine Condition Monitoring (MCM) test bed at INL will be used to demonstrate the effectiveness to advancement in online monitoring, sensors, diagnostic and prognostic technologies on a pilot-scale plant that mimics the hydraulics of a nuclear plant. As part of this research project, INL will research available prognostics architectures and their suitability for deployment in a nuclear power plant. In addition, INL will provide recommendation to improve the existing diagnostic and prognostic architectures based on the experimental analysis performed on the MCM test bed.

  1. Nuclear Energy Research Initiative (NERI): On-Line Intelligent Self-Diagnostic Monitoring for Next Generation Nuclear Plants - Phase I Annual Report

    International Nuclear Information System (INIS)

    Bond, L.G.; Doctor, S.R.; Gilbert, R.W.; Jarrell, D.B.; Greitzer, F.L.; Meador, R.J.

    2000-01-01

    OAK-B135 This OSTI ID belongs to an IWO and is being released out of the system. The Program Manager Rebecca Richardson has confirmed that all reports have been received. The objective of this project is to design and demonstrate the operation of the real-time intelligent self-diagnostic and prognostic system for next generation nuclear power plant systems. This new self-diagnostic technology is titled, ''On-Line Intelligent Self-Diagnostic Monitoring System'' (SDMS). This project provides a proof-of-principle technology demonstration for SDMS on a pilot plant scale service water system, where a distributed array of sensors is integrated with active components and passive structures typical of next generation nuclear power reactor and plant systems. This project employs state-of-the-art sensors, instrumentation, and computer processing to improve the monitoring and assessment of the power reactor system and to provide diagnostic and automated prognostics capabilities

  2. Prototyping low-cost and flexible vehicle diagnostic systems

    Directory of Open Access Journals (Sweden)

    Marisol GARCÍA-VALLS

    2016-12-01

    Full Text Available Diagnostic systems are software and hardware-based equipment that interoperate with an external monitored system. Traditionally, they have been expensive equipment running test algorithms to monitor physical properties of, e.g., vehicles, or civil infrastructure equipment, among others. As computer hardware is increasingly powerful (whereas its cost and size is decreasing and communication software becomes easier to program and more run-time efficient, new scenarios are enabled that yield to lower cost monitoring solutions. This paper presents a low cost approach towards the development of a diagnostic systems relying on a modular component-based approach and running on a resource limited embedded computer. Results on a prototype implementation are shown that validate the presented design, its flexibility, performance, and communication latency.

  3. Dengue viral infection monitoring from diagnostic to recovery using Raman spectroscopy

    International Nuclear Information System (INIS)

    Firdous, Shamaraz; Anwar, Shahzad

    2015-01-01

    Raman spectroscopy has been found useful for monitoring the dengue patient diagnostic and recovery after infection. In the present work, spectral changes that occurred in the blood sera of a dengue infected patient and their possible utilization for monitoring of infection and recovery were investigated using 532 nm wavelength of light. Raman spectrum peaks for normal and after recovery of dengue infection are observed at 1527, 1170, 1021 cm −1 attributed to guanine, adenine, TRP (protein) carbohydrates peak for solids, and skeletal C–C stretch of lipids acyl chains. Where in the dengue infected patient Raman peaks are at 1467, 1316, 1083, and 860 attributed to CH2/CH3 deformation of lipids and collagen, guanine (B, Z-marker), lipids and protein bands. Due to antibodies and antigen reactions the portions and lipids concentration totally changes in dengue viral infection compared to normal blood. These chemical changes in blood sera of dengue viral infection in human blood may be used as possible markers to indicate successful remission and suggest that Raman spectroscopy may provide a rapid optical method for continuous monitoring or evaluation of a protein bands and an antibodies population. Accumulate acquisition mode was used to reduce noise and thermal fluctuation and improve signal to noise ratio. This in vitro dengue infection monitoring methodology will lead in vivo noninvasive on-line monitoring and screening of viral infected patients and their recovery. (letter)

  4. Emergency CT brain: preliminary interpretation with a tablet device: image quality and diagnostic performance of the Apple iPad.

    LENUS (Irish Health Repository)

    Mc Laughlin, Patrick

    2012-04-01

    Tablet devices have recently been used in radiological image interpretation because they have a display resolution comparable to desktop LCD monitors. We identified a need to examine tablet display performance prior to their use in preliminary interpretation of radiological images. We compared the spatial and contrast resolution of a commercially available tablet display with a diagnostic grade 2 megapixel monochrome LCD using a contrast detail phantom. We also recorded reporting discrepancies, using the ACR RADPEER system, between preliminary interpretation of 100 emergency CT brain examinations on the tablet display and formal review on a diagnostic LCD. The iPad display performed inferiorly to the diagnostic monochrome display without the ability to zoom. When the software zoom function was enabled on the tablet device, comparable contrast detail phantom scores of 163 vs 165 points were achieved. No reporting discrepancies were encountered during the interpretation of 43 normal examinations and five cases of acute intracranial hemorrhage. There were seven RADPEER2 (understandable) misses when using the iPad display and 12 with the diagnostic LCD. Use of software zoom in the tablet device improved its contrast detail phantom score. The tablet allowed satisfactory identification of acute CT brain findings, but additional research will be required to examine the cause of "understandable" reporting discrepancies that occur when using tablet devices.

  5. Research and Development of Hybrid Electric Vehicles CAN-Bus Data Monitor and Diagnostic System through OBD-II and Android-Based Smartphones

    Directory of Open Access Journals (Sweden)

    Yalian Yang

    2013-01-01

    Full Text Available With the rapid development of the smartphone market, future cars seem to have more connections with intelligent cell phone and Internet. Intelligent transportation system (ITS and telematics system have become research focus in recent years. There is an increasing demand for remote monitoring and diagnostic system as the further research of hybrid electric vehicle (HEV goes on. In this paper, a remote controller area network bus (CAN-Bus data monitor and diagnostic system for HEV is presented using on board diagnostic version-II (OBD-II and Android-based smartphone. It is low-cost, convenient, and extensible with smartphone used in the system to realize communication with ELM327 and remote monitoring center wirelessly. The prototype of client and server is developed in Java language, and it is proved by the test that the system works stably and the collected data have practical values.

  6. Poor academic performance: A perspective of final year diagnostic radiography students

    International Nuclear Information System (INIS)

    Gqweta, Ntokozo

    2012-01-01

    Introduction: A study was conducted on final year diagnostic radiography students at a University of Technology in Durban. The aim of the study was to investigate the final year diagnostic radiography students' opinions and views on academic performance in order to inform teaching and learning methods. The objectives were: •To explore the students' opinions regarding poor performance. •To identify strategies to improve academic performance. Method: A qualitative, interpretive approach was used to explain and understand the students' lived experiences of their academic performances. A short open ended questionnaire was administered to a cohort of final diagnostic radiography students following feedback on a written assessment. Questionnaire responses were then manually captured and analyzed. Results: Five (5) themes were identified that could possibly be associated with poor academic performance. These themes were, poor preparation, lack of independent study, difficulty in understanding learning content and misinterpretation of assessment questions, inefficient studying techniques as well as perceived improvement strategies. Conclusion: Students identified their inadequate preparation and the lack of dedicated independent studying as the main reasons for poor performance. Students preferred to be taught in an assessment oriented manner. However their identified improvement strategies were aligned with the learner centred approach.

  7. Modular Software Performance Monitoring

    CERN Document Server

    Kruse, D F

    2011-01-01

    CPU clock frequency is not likely to be increased significantly in the coming years, and data analysis speed can be improved by using more processors or buying new machines, only if one is willing to change the paradigm to a parallel one. Therefore, performance monitoring procedures and tools are needed to help programmers to optimize existing software running on current and future hardware. Low level information from hardware performance counters is vital to spot specific performance problems slowing program execution. HEP software is often huge and complex, and existing tools are unable to give results with the required granularity. We will report on the approach we have chose to solve this problem that involves decomposing the application into parts and monitoring each of them separately. Both counting and sampling methods are used to allow an analysis with the required custom granularity: from global level, up to the function level. A set of tools (based on perfmon2 – a software interface to hardware co...

  8. Nuclear Energy Research Initiative (NERI): On-Line Intelligent Self-Diagnostic Monitoring for Next Generation Nuclear Plants - Phase I Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    L. J. Bond; S. R. Doctor; R. W. Gilbert; D. B. Jarrell; F. L. Greitzer; R. J. Meador

    2000-09-01

    OAK-B135 This OSTI ID belongs to an IWO and is being released out of the system. The Program Manager Rebecca Richardson has confirmed that all reports have been received. The objective of this project is to design and demonstrate the operation of the real-time intelligent self-diagnostic and prognostic system for next generation nuclear power plant systems. This new self-diagnostic technology is titled, ''On-Line Intelligent Self-Diagnostic Monitoring System'' (SDMS). This project provides a proof-of-principle technology demonstration for SDMS on a pilot plant scale service water system, where a distributed array of sensors is integrated with active components and passive structures typical of next generation nuclear power reactor and plant systems. This project employs state-of-the-art sensors, instrumentation, and computer processing to improve the monitoring and assessment of the power reactor system and to provide diagnostic and automated prognostics capabilities.

  9. Study of the performance of diagnostic radiology instruments during calibration

    International Nuclear Information System (INIS)

    Freitas, Rodrigo N. de; Vivolo, Vitor; Potiens, Maria da Penha A.

    2008-01-01

    Full text: The instruments used in diagnostic radiology measurements represent 8 % of the tested instruments by the calibration laboratory of IPEN annually (approximately 1600 in 2007). Considering that the calibration of this kind of instrument is performed biannually it is possible to conclude that almost 300 instruments are being used to measure the air kerma in diagnostic radiology clinics to determine the in beam values (in front of the patient), attenuated measurements (behind the patient) and scattered radiation. This work presents the results of the calibration of the instruments used in mammography, computed tomography, dental and conventional diagnostic radiology dosimetry, performed during the period of 2005 to 2007. Their performances during the calibrations measurements were evaluated. Although at the calibration laboratory there are three available series of radiation quality to this type of calibration (RQR, N and M, according to standards IEC 61267 and ISO 4037-1.), the applications can be assorted (general radiology, computed tomography, mammography, radiation protection and fluoroscopy). Depending on its design and behaviour , one kind of instrument can be used for one or more type of applications. The instruments normally used for diagnostic radiology measurements are ionization chambers with volumes varying from 3 to 1800 cm 3 , and can be cylindrical, spherical or plane parallel plates kind. They usually are sensitive to photon particles, with energies greater than 15 keV and can be used up to 1200 keV. In this work they were tested in X radiation fields from 25 to 150 kV, in specific qualities depending on the utilization of the instrument. The calibration results of 390 instruments received from 2005 to 2007 were analyzed. About 20 instruments were not able to be calibrated due to bad functioning. The calibration coefficients obtained were between 0.88 and 1.24. The uncertainties were always less than ± 3.6% to instruments used in scattered

  10. A Framework to Debug Diagnostic Matrices

    Science.gov (United States)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  11. Development of a reactor-coolant-pump monitoring and diagnostic system. Semi-annual progress report, December 1981-May 1982

    International Nuclear Information System (INIS)

    Morris, D.J.; Gabler, H.C.

    1982-10-01

    Reactor coolant (RC) pump seal failures have resulted in excessive leakage of primary coolant into reactor containment buildings. In some cases, high levels of airborne activity and surface contamination following these failures have necessitated extensive cleanup efforts and personnel radiation exposure. Unpredictable pump seal performance has also caused forced outages and frequent maintenance. The quality of operating data has been insufficient to allow proper evaluation of theoretical RC pump seal failure mechanisms. The RC pump monitoring and diagnostic system being developed and installed at Toledo Edison's Davis-Besse Nuclear Power Station will examine the relationship between seal failures and three other variables. This report describes system software and hardware development, testing, and installation work performed during the period of December 1981 through May 1982. Also described herein is a parallel effort being conducted by a B and W/Byron Jackson/Utility group to improve pump seal performance

  12. Diagnostic system and diagnostic experiences at the Paks Nuclear Power Plant

    International Nuclear Information System (INIS)

    Katona, Tamas

    1986-01-01

    The major functions of the diagnostic system of the first two units of the Paks Nuclear Power Plant are as follows: monitoring the mechanical integrity of the reactor and the primary coolant circuit by means of vibration diagnostics; leakage detection of the primary coolant circuit by means of high frequency sonic analysis; loose parts monitoring based on the analysis of high frequency signals of acceleration detectors; and monitoring the vibration state of the turbines and rotary machines by the latter method or by a procedure based on the detection of mechanical vibrations. Up-to-date vibration diagnostics is based on the information supplied by either acceleration detectors or pressure fluctuation detectors, or in-core and ex-core neutron detectors. (V.N.)

  13. Effective diagnostic DAQ systems to reduce unnecessary data in KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Taegu, E-mail: glory@nfri.re.kr; Lee, Woongryol; Hong, Jaesic; Park, Kaprai

    2016-11-15

    Highlights: • When plasma shots do not successfully perform during the intended target time, the diagnostics systems continue to record these unusable data, contributing to increasing data size. • To overcome this problem, some KSTAR’s library were upgraded to monitor the plasma status in real-time. • With the real-time information of plasma status, some of the KSTAR diagnostic systems stop the acquisition process of unnecessary data. • We were able to reduce the refuse data of approximately 698 GByte in the KSTAR 7th campaign. • It was a very effective way to store useful data, and it was helpful to analysts after shot. - Abstract: The plasma status of Korea Superconducting Tokamak Advanced Research (KSTAR) is measured by various diagnostics systems. The measured data size has been increasing every year due to increasing plasma pulse lengths, higher diagnostics operating frequencies, the additions of new diagnostic systems, and an increasing number of diagnostics channels. At times, when plasma shots do not successfully perform during the intended target time, the diagnostics systems continue to record these unusable data, contributing to increasing data size. In addition, the analysis time was affected, as these data need to be separated from the relevant data set. To overcome this problem, KSTAR’s Standard Framework (SFW), Real Time Monitoring (RTMON), and Pulse Automation and Scheduling System (PASS) were upgraded to monitor the plasma status in real-time. When the plasma current is less than 200kA, RTMON sends the plasma status information every second to the SFW via EPICS Channel Access. With the real-time information on plasma status, some of the KSTAR diagnostic systems stop the acquisition process of unnecessary data. This paper describes a method for reducing the storage of unnecessary data and its results in the KSTAR 7th campaign.

  14. Allowable stem nut wear and diagnostic monitoring for MOVs

    International Nuclear Information System (INIS)

    Swinburne, P.

    1994-01-01

    After a motor-operated valve (MOV) stem nut failure in 1991 that contributed to a forced plant shutdown, the FitzPatrick Plant staff developed criteria to check for excessive stem nut wear in MOVs. Allowable stem nut wear monitoring uses both direct dimensional measurement and diagnostic test data interpretation. The wear allowance is based on the recommended permitted backlash discussed in the Electric Power Research Institute/Nuclear Maintenance Assistance Center Technical Repair Guideline for the Limitorque SMB-000 Motor Actuator. The diagnostic analysis technique measures the time at zero load and compares this with a precalculated allowable zero force time. Excessive zero force time may be the result of other MOV problems, such as a loose stem nut lock nut or excessive free play in the drive sleeve bearing. Stress levels for new or nominal stem nuts and stem nuts with the full wear allowance were compared. Bending and shear stresses at the thread root increase for the maximum wear condition when compared with a open-quotes newclose quotes stem nut. These stresses are directly related to the thread root thickness. For typical MOV loading and common stem threading (with two diameters of thread engagement), the thread stresses are well within acceptable limits for ASTM B584-C86300 (formerly B147-863) manganese bronze (typical stem nut material)

  15. WiMAX network performance monitoring & optimization

    DEFF Research Database (Denmark)

    Zhang, Qi; Dam, H

    2008-01-01

    frequency reuse, capacity planning, proper network dimensioning, multi-class data services and so on. Furthermore, as a small operator we also want to reduce the demand for sophisticated technicians and man labour hours. To meet these critical demands, we design a generic integrated network performance......In this paper we present our WiMAX (worldwide interoperability for microwave access) network performance monitoring and optimization solution. As a new and small WiMAX network operator, there are many demanding issues that we have to deal with, such as limited available frequency resource, tight...... this integrated network performance monitoring and optimization system in our WiMAX networks. This integrated monitoring and optimization system has such good flexibility and scalability that individual function component can be used by other operators with special needs and more advanced function components can...

  16. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    OpenAIRE

    Marchevsky, M.; Wang, X.; Sabbi, G.; Prestemon, S.

    2014-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb3Sn quadrupole HQ01 [...

  17. Methods Developed by the Tools for Engine Diagnostics Task to Monitor and Predict Rotor Damage in Real Time

    Science.gov (United States)

    Baaklini, George Y.; Smith, Kevin; Raulerson, David; Gyekenyesi, Andrew L.; Sawicki, Jerzy T.; Brasche, Lisa

    2003-01-01

    Tools for Engine Diagnostics is a major task in the Propulsion System Health Management area of the Single Aircraft Accident Prevention project under NASA s Aviation Safety Program. The major goal of the Aviation Safety Program is to reduce fatal aircraft accidents by 80 percent within 10 years and by 90 percent within 25 years. The goal of the Propulsion System Health Management area is to eliminate propulsion system malfunctions as a primary or contributing factor to the cause of aircraft accidents. The purpose of Tools for Engine Diagnostics, a 2-yr-old task, is to establish and improve tools for engine diagnostics and prognostics that measure the deformation and damage of rotating engine components at the ground level and that perform intermittent or continuous monitoring on the engine wing. In this work, nondestructive-evaluation- (NDE-) based technology is combined with model-dependent disk spin experimental simulation systems, like finite element modeling (FEM) and modal norms, to monitor and predict rotor damage in real time. Fracture mechanics time-dependent fatigue crack growth and damage-mechanics-based life estimation are being developed, and their potential use investigated. In addition, wireless eddy current and advanced acoustics are being developed for on-wing and just-in-time NDE engine inspection to provide deeper access and higher sensitivity to extend on-wing capabilities and improve inspection readiness. In the long run, these methods could establish a base for prognostic sensing while an engine is running, without any overt actions, like inspections. This damage-detection strategy includes experimentally acquired vibration-, eddy-current- and capacitance-based displacement measurements and analytically computed FEM-, modal norms-, and conventional rotordynamics-based models of well-defined damages and critical mass imbalances in rotating disks and rotors.

  18. FASTBUS Snoop Diagnostic Module

    International Nuclear Information System (INIS)

    Walz, H.V.; Downing, R.

    1980-11-01

    Development of the FASTBUS Snoop Module, undertaken as part of the prototype program for the new interlaboratory data bus standard, is described. The Snoop Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. Communication with a remote host computer is handled independent of FASTBUS through a serial link. The module consists of a high-speed ECL front-end to monitor and single-step FASTBUS cycles, a master-slave interface, and a control microprocessor with serial communication ports. Design details and performance specifications of the prototype module are reported. 9 figures, 1 table

  19. Challenges to Providing a Successful Central Configuration Service to Support CERN’s New Controls Diagnostics and Monitoring System

    CERN Document Server

    Makonnen, Z; Zaharieva, Z

    2014-01-01

    The Controls Diagnostic and Monitoring service (DIAMON) provides monitoring and diagnostics tools to the operators in the CERN Control Centre. A recent reengineering presented the opportunity to restructure its data management and to integrate it with the central Controls Configuration Service (CCS). The CCS provides the Configuration Management for the Controls System for all accelerators at CERN. The new facility had to cater for the configuration management of all agents monitored by DIAMON, (>3000 computers of different types), provide deployment information, relations between metrics, and historical information. In addition, it had to be integrated into the operational CCS, while ensuring stability and data coherency. An important design decision was to largely reuse the existing infrastructure in the CCS and adapt the DIAMON data management to it e.g. by using the device/property model through a Virtual Devices framework to model the DIAMON agents. This article will show how these challenging requiremen...

  20. Performance studies of the vibration wire monitor on the test stand with low energy electron beam

    International Nuclear Information System (INIS)

    Okabe, Kota; Yoshimoto, Masahiro; Kinsho, Michikazu

    2015-01-01

    In the high intensity proton accelerator as the Japan Proton Accelerator Research Complex (J-PARC) accelerators, serious radiation and residual dose is induced by a small beam loss such a beam halo. Therefore, diagnostics of the beam halo formation is one of the most important issues to control the beam loss. For the beam halo monitor, the vibration wire monitor (VWM) has a potential for investigating the beam halo and weak beam scanning. The VWM has a wide dynamic range, high resolution and the VWM is not susceptible to secondary electrons and electric noises. We have studied the VWM features as a new beam-halo monitor on the test stand with low energy electron gun. The frequency shift of the irradiated vibration wire was confirmed about wire material and the electron beam profile measured by using the VWM was consistent with the results of the Faraday cup measurement. Also we calculated a temperature distribution on the vibration wire which is irradiated by the electron beam with the numerical simulation. The simulations have been fairly successful in reproducing the transient of the irradiated vibration wire frequency measured by test stand experiments. In this paper, we will report a result of performance evaluation for the VWM on the test stands and discuss the VWM for beam halo diagnostic. (author)

  1. General review of diagnostic systems in EDF PWR units

    International Nuclear Information System (INIS)

    Chevalier, R.; Brasseur, S.; Ricard, B.

    1998-01-01

    Since the beginning of the French nuclear program, Electricite de France (EDF) has looked for ways to improve the availability and safety of its nuclear units. Therefore, monitoring systems on turbogenerators, reactor coolant pumps, primary circuits and core internal structures were designed by the Research and Development Division and implemented with technologies available during the 1970's. However, mainly because of difficulties for data interpretation by plant personnel, EDF subsequently decided to design and develop different tools to help plant operators to process a diagnosis: - a new generation of the Monitoring and Diagnostic System called PSAD, - expert systems for diagnosis on reactor coolant pumps (RCP) 'DIAPO' and turbogenerator units (TG) 'DIVA', - diagnostic guides written for most equipment pending the installation of new monitoring and diagnosis systems. The first version of PSAD, installed in five units, performs on-line monitoring of the turbogenerator shaft line, steam inlet valves, the reactor coolant pumps and the generator stator. The second version not yet implemented, will include Loose Part Detection (LPD) and Core Internal Structure Monitoring (CISM). The level of diagnosis achieved by PSAD depends on the component monitored. The TG and RCP monitoring functions of PSAD compute high level diagnosis descriptors such as natural frequencies and long term trends but do not elaborate a diagnosis automatically. However, a diagnostic assistance window is available on-line, whenever a warning message is displayed, whether for immediate or later action. The window presents a diagnostic approach whose purpose is to find the causes of the symptoms observed. This diagnosis approach is automated in the DIVA and DIAPO expert systems. Numerous potential faults can be identified for both systems thanks to a hierarchy of abnormal situations. The user interactively answers questions when information is needed to progress in the diagnosis. The resulting

  2. Diagnostic systems developed in NPPRI (VUJE) Trnava Inc. for NPPs

    International Nuclear Information System (INIS)

    Kucharek, P.

    1998-01-01

    Since foundation of Nuclear Power Plant Research Institute (NPPRI) in 1977, the department of diagnostics has been dealt with problems related to the theoretical, practical and organizatory questions of operational diagnostics connected with PWR type nuclear components. This department acts directly in locality of NPP Jaslovske Bohunice, but there are performances for all NPP in Slovak or Czech Republic (Dukovany, Mochovce, and Temelin). Besides direct services and achievements for NPP there exist advisory, experts and research activities for the government and supervising authorities, too. In 1985, NPPRI began systematically construct and verify technical means for operational diagnostics of main circulating pumps (MCP) with good results, based on own rich practical experiences and contacts with organisations abroad. In recent years NPPRI as one of recognised qualified and authorised institutions in Slovak Republic has begun to develop a new generation of diagnostic systems for NPP on high technical level but with lower procuring costs in comparison with western countries products. This contribution deals with four following types of diagnostic systems which were not only developed but also delivered and installed on Slovak and Czech nuclear units: - Loose part monitoring system (LPMS), - Humidity monitoring system (HUMON), - Reactor coolant pumps monitoring system (RCPMS), - Primary circuit vibration monitoring system (VMS). Main features of new generation from middle of 1990's of these systems are described in this paper and operational experiences with them too. (author)

  3. Enhancing reactor availability factor by diagnostic monitoring and data acquisition of electrical equipments

    International Nuclear Information System (INIS)

    Singh, G.

    2006-01-01

    Electrical energy has made significant contribution to rapid growth of industrial activity in the country. Development and improvement of energy conversion devices or electrical apparatus have supported the growth. Reliability is probably the most important factor in electrical supply system, not only to give uninterrupted service but to provide an economic supply. Regular diagnostic testing of electrical equipments will make a significant contribution to the reliability of electrical supply. The purpose of diagnostic monitoring is to recognize the development of faults at an early stage, which consequently allows greater freedom to schedule the outages resulting in lower downtime and lower capitalized losses. The insulation constitutes the heart of any electrical/power equipment. The insulation in power equipment in normal condition undergoes certain changes in the physical, chemical, electrical and mechanical properties. The change with respect to time in the presence of an influencing factor, more often a stress (electrical) is referred to as ageing. The deterioration of insulating material plays an important role in the assessing the condition of electrical equipments. The systematic diagnostic tests are also part of the maintenance program to ensure the continued serviceability of electrical equipments, by replacing or repairing the components likely to fail, as revealed by the test. Diagnostic tests are carried out on various electrical equipments for detection of incipient fault, location and judging their severity. (author)

  4. Reactor coolant pump monitoring and diagnostic system

    International Nuclear Information System (INIS)

    Singer, R.M.; Gross, K.C.; Walsh, M.; Humenik, K.E.

    1990-01-01

    In order to reliably and safely operate a nuclear power plant, it is necessary to continuously monitor the performance of numerous subsystems to confirm that the plant state is within its prescribed limits. An important function of a properly designed monitoring system is the detection of incipient faults in all subsystems (with the avoidance of false alarms) coupled with an information system that provides the operators with fault diagnosis, prognosis of fault progression and recommended (either automatic or prescriptive) corrective action. In this paper, such a system is described that has been applied to reactor coolant pumps. This system includes a sensitive pattern-recognition technique based upon the sequential probability ratio test (SPRT) that detects incipient faults from validated signals, an expert system embodying knowledge bases on pump and sensor performance, extensive hypertext files containing operating and emergency procedures as well as pump and sensor information and a graphical interface providing the operator with easily perceived information on the location and character of the fault as well as recommended corrective action. This system is in the prototype stage and is currently being validated utilizing data from a liquid-metal cooled fast reactor (EBR-II). 3 refs., 4 figs

  5. NPP Mochovce units 1 and 2 diagnostic systems

    International Nuclear Information System (INIS)

    Heidenreich, S.

    1997-01-01

    In this paper the diagnostic systems (leak detection monitoring, vibration monitoring, lose parts monitoring, fatigue monitoring) of NPP Mochovce units 1 and 2 are presented. All of the designed diagnostic systems are personal computer based systems

  6. Performance audit procedures for opacity monitors

    International Nuclear Information System (INIS)

    Plaisance, S.J.; Peeler, J.W.

    1987-04-01

    This manual contains monitor-specific performance audit procedures and data forms for use in conducting audits of installed opacity continuous emission monitoring systems (CEMS). General auditing procedures and acceptance limits for various audit criteria are discussed. Practical considerations and common problems encountered in conducting audits are delineated, and recommendations are included to optimize the successful completion of performance audits. Performance audit procedures and field-data forms were developed for six common opacity CEMS: (1) Lear Siegler, Inc. Model RM-41; (2) Lear Siegler, Inc. Model RM-4; (3) Dynatron Model 1100; (4) Thermo Electron, Inc. Model 400; (5) Thermo Electron, Inc. Model 1000A; and (6) Enviroplan Model D-R280 AV. Generic audit procedures are included for use in evaluating opacity CEMS with multiple transmissometers and combiner devices. In addition, several approaches for evaluating the zero-alignment or clear-path zero response are described. The zero-alignment procedures are included since the factor is fundamental to the accuracy of opacity monitoring data, even though the zero-alignment checks cannot usually be conducted during a performance audit

  7. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA

    Directory of Open Access Journals (Sweden)

    Christie E Tung

    2015-01-01

    Full Text Available Background: It is important to evaluate patients with TIA or stroke for atrial fibrillation (AF because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch in patients with stroke or TIA.Methods: We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies. Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. Results: 1,171 monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0. The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%. AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 hours. The mean PAF burden was 12.7% of the total monitoring duration. Conclusion: Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 hours of monitoring suggest that the cardiac patch is superior to conventional 48-hour Holter monitors for AF detection in patients with stroke or TIA.

  8. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA.

    Science.gov (United States)

    Tung, Christie E; Su, Derek; Turakhia, Mintu P; Lansberg, Maarten G

    2014-01-01

    It is important to evaluate patients with transient ischemic attack (TIA) or stroke for atrial fibrillation (AF) because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch) in patients with stroke or TIA. We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies). Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. One thousand one hundred seventy-one monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0). The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%). AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF) was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 h. The mean PAF burden was 12.7% of the total monitoring duration. Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 h of monitoring suggest that the cardiac patch is superior to conventional 48-h Holter monitors for AF detection in patients with stroke or TIA.

  9. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 18

    International Nuclear Information System (INIS)

    Pazsit, Imre; Nam, Tran Hoai; Dykin, Victor; Jonsson, Anders

    2013-01-01

    This report constitutes Stage 18 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The objective of the research program is to contribute to the strategic research goal of competence and research capacity by building up competence within the Department of Nuclear Engineering at Chalmers University of Technology, regarding reactor physics, reactor dynamics and noise diagnostics. The purpose is also to contribute to the research goal of giving a basis for SSM's supervision by developing methods for identification and localization of perturbations in reactor cores. Results up to Stage 17 were reported in SKI and SSM reports, as listed in the report's summary

  10. Conceptual design of neutron diagnostic systems for fusion experimental reactor

    International Nuclear Information System (INIS)

    Iguchi, T.; Kaneko, J.; Nakazawa, M.

    1994-01-01

    Neutron measurement in fusion experimental reactors is very important for burning plasma diagnostics and control, monitoring of irradiation effects on device components, neutron source characterization for in-situ engineering tests, etc. A conceptual design of neutron diagnostic systems for an ITER-like fusion experimental reactor has been made, which consists of a neutron yield monitor, a neutron emission profile monitor and a 14-MeV spectrometer. Each of them is based on a unique idea to meet the required performances for full power conditions assumed at ITER operation. Micro-fission chambers of 235 U (and 238 U) placed at several poloidal angles near the first wall are adopted as a promising neutron yield monitor. A collimated long counter system using a 235 U fission chamber and graphite neutron moderators is also proposed to improve the calibration accuracy of absolute neutron yield determination

  11. High-performance pickups for beam diagnostics. Design, analysis, characterization and implementation

    International Nuclear Information System (INIS)

    Angelovski, Aleksandar

    2015-01-01

    This work introduces the design, analysis, characterization and implementation of high-performance pickups for two beam diagnostic instruments, a Bunch Arrival-time Monitor (BAM) and an Energy Beam Position Monitor (EBPM) at the European XFEL. As a part of the BAM the cone-shaped pickups are proposed along with the corresponding RF-frontend. The designed pickups deliver a beam induced signal with a slope steepness of around 400 mV/ps and a bandwidth of 40 GHz. These signal characteristics are well inside the design requirements, i.e., a slope steepness of 300 mV/ps and more than ten times better compared to the signal from the state-of-the-art pickups. The pickups are installed and commissioned at three accelerator facilities, FLASH at DESY, the quasi-CW SRF accelerator ELBE at the Helmholtz-Zentrum Dresden-Rossendorf and the SwissFEL injector test facility at Paul Scherrer Institute. The obtained measurement results from the installed pickups are in good agreement with the simulations. A comparison between the signal measurements with the cone-shaped pickup and the state-of-the-art is performed at ELBE showing an improvement by a factor of ten. The potential of the pickups for sub-10 fs arrival-time measurements for bunch charges of 20 pC is demonstrated at ELBE and at SwissFEL injector test facility. The introduced coneshaped pickups are the first commercially available pickups with a bandwidth of up to 40 GHz. For the EBPM, a modular pickup structure with two types of planar pickups, microstrip transmission line and grounded coplanar waveguide with perpendicular connectors is investigated. The transition region between the connector and the line is optimized for two substrate materials, alumina and glass with a reflection coefficient better than -20 dB up to 6 GHz.

  12. 5 CFR 430.207 - Monitoring performance.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Monitoring performance. 430.207 Section 430.207 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERFORMANCE MANAGEMENT Performance Appraisal for General Schedule, Prevailing Rate, and Certain Other Employees § 430.207...

  13. Radiation effects in IFMIF Li target diagnostic systems

    International Nuclear Information System (INIS)

    Molla, J.; Vila, R.; Shikama, T.; Horiike, H.; Simakov, S.; Ciotti, M.; Ibarra, A.

    2009-01-01

    Diagnostics for the lithium target will be crucial for the operation of IFMIF. Several parameters as the lithium temperature, target thickness or wave pattern must be monitored during operation. Radiation effects may produce malfunctioning in any of these diagnostics due to the exposure to high radiation fields. The main diagnostic systems proposed for the operation of IFMIF are reviewed in this paper from the point of view of radiation damage. The main tools for the assessment of the performance of these diagnostics are the neutronics calculations by using specialised codes and the information accumulated during the last decades on the radiation effects in functional materials, components and diagnostics for ITER. This analysis allows to conclude that the design of some of the diagnostic systems must be revised to assure the high availability required for the target system.

  14. Performance of diagnostic mammography differs in the United States and Denmark

    DEFF Research Database (Denmark)

    Jensen, Allan; Geller, Berta M; Gard, Charlotte C

    2010-01-01

    in the United States and Denmark. The performance of 93,585 diagnostic mammograms from 180 facilities contributing data to the US Breast Cancer Surveillance Consortium (BCSC) from 1999 to 2001 was compared to that of all 51,313 diagnostic mammograms performed at Danish clinics in 2000. We used the imaging...... workup's final assessment to determine sensitivity, specificity and an estimate of accuracy: area under the receiver-operating characteristics (ROCs) curve (AUC). Diagnostic mammography had slightly higher sensitivity in the United States (85%) than in Denmark (82%). In contrast, it had higher...... specificity in Denmark (99%) than in the United States (93%). The AUC was high in both countries: 0.91 in United States and 0.95 in Denmark. Denmark's higher accuracy may result from supplementary ultrasound examinations, which are provided to 74% of Danish women but only 37% to 52% of US women. In addition...

  15. Performance results of cooperating expert systems in a distributed real-time monitoring system

    Science.gov (United States)

    Schwuttke, U. M.; Veregge, J. R.; Quan, A. G.

    1994-01-01

    There are numerous definitions for real-time systems, the most stringent of which involve guaranteeing correct system response within a domain-dependent or situationally defined period of time. For applications such as diagnosis, in which the time required to produce a solution can be non-deterministic, this requirement poses a unique set of challenges in dynamic modification of solution strategy that conforms with maximum possible latencies. However, another definition of real time is relevant in the case of monitoring systems where failure to supply a response in the proper (and often infinitesimal) amount of time allowed does not make the solution less useful (or, in the extreme example of a monitoring system responsible for detecting and deflecting enemy missiles, completely irrelevant). This more casual definition involves responding to data at the same rate at which it is produced, and is more appropriate for monitoring applications with softer real-time constraints, such as interplanetary exploration, which results in massive quantities of data transmitted at the speed of light for a number of hours before it even reaches the monitoring system. The latter definition of real time has been applied to the MARVEL system for automated monitoring and diagnosis of spacecraft telemetry. An early version of this system has been in continuous operational use since it was first deployed in 1989 for the Voyager encounter with Neptune. This system remained under incremental development until 1991 and has been under routine maintenance in operations since then, while continuing to serve as an artificial intelligence (AI) testbed in the laboratory. The system architecture has been designed to facilitate concurrent and cooperative processing by multiple diagnostic expert systems in a hierarchical organization. The diagnostic modules adhere to concepts of data-driven reasoning, constrained but complete nonoverlapping domains, metaknowledge of global consequences of anomalous

  16. PREFACE: 25th International Congress on Condition Monitoring and Diagnostic Engineering (COMADEM 2012)

    Science.gov (United States)

    Ball, Andrew; Mishra, Rakesh; Gu, Fengshou; Rao, Raj B. K. N.

    2012-05-01

    The proactive multidisciplinary conceptual philosophy of Condition Monitoring and Diagnostic Engineering Management (COMADEM) was conceived and has been nurtured, developed and sustained since 1988. Since then, it is gratifying to note that the condition monitoring, diagnostic and prognostic community worldwide (representing industrialists, academics, research and development organizations, professional/private establishments and many hardware/software vending organizations) has warmly welcomed and supported this venture. As is evidenced, many have reaped (and are reaping) the benefits of COMADEM interdiscipline through continuous knowledge discovery, generation and dissemination. We are now proud to celebrate the 25th Annual Event (Silver Jubilee) in Huddersfield, the most beautiful part of the United Kingdom. The theme of this Congress is 'Sustained Prosperity through Proactive Monitoring, Diagnosis, Prognosis and Management'. This proceedings is enriched by contributions from many keynote experts representing many industry and academic establishments worldwide. Authors from more than 30 different countries have pooled their rich multidisciplinary up-to-date knowledge, in order to share their invaluable experience with the COMADEM community. In this proceedings, the readers will find more than 120 refereed papers encompassing a number of topical areas of interest relating to the theme of the congress. The proceedings of COMADEM 2012 will appear in the Open Access Journal of Physics: Conference Series (JPCS), which is part of the IOP Conference Series. All papers published in the IOP Conference Series are fully citable and upon publication will be free to download. We would like to express our deep gratitude to all the keynote speakers, authors, referees, exhibitors, Technical Co-Sponsoring Organizations, Gold Sponsors, IOP Publishers, COMADEM 2012 organizing committee members, delegates and many others on whom the success of this prestigious event depends

  17. Plant performance monitoring program at Krsko NPP

    International Nuclear Information System (INIS)

    Bach, B.; Kavsek, D.

    2004-01-01

    A high level of nuclear safety and plant reliability results from the complex interaction of a good design, operational safety and human performance. This is the reason for establishing a set of operational plant safety performance indicators, to enable monitoring of both plant performance and progress. Performance indicators are also used for setting challenging targets and goals for improvement, to gain additional perspective on performance relative to other plants and to provide an indication of a potential need to adjust priorities and resources to achieve improved overall plant performance. A specific indicator trend over a certain period can provide an early warning to plant management to evaluate the causes behind the observed changes. In addition to monitoring the changes and trends, it is also necessary to compare the indicators with identified targets and goals to evaluate performance strengths and weaknesses. Plant Performance Monitoring Program at Krsko NPP defines and ensures consistent collection, processing, analysis and use of predefined relevant plant operational data, providing a quantitative indication of nuclear power plant performance. When the program was developed, the conceptual framework described in IAEA TECDOC-1141 Operational Safety Performance Indicators for Nuclear Power Plants was used as its basis in order to secure that a reasonable set of quantitative indications of operational safety performance would be established. Safe, conservative, cautious and reliable operation of the Krsko NPP is a common goal for all plant personnel. It is provided by continuous assurance of both health and safety of the public and employees according to the plant policy stated in program MD-1 Notranje usmeritve in cilji NEK, which is the top plant program. Establishing a program of monitoring and assessing operational plant safety performance indicators represents effective safety culture of plant personnel.(author)

  18. Diagnostics and performance evaluation of multikilohertz capacitors

    International Nuclear Information System (INIS)

    McDuff, G.; Nunnally, W.C.; Rust, K.; Sarjeant, J.

    1980-01-01

    The observed performance of nanofarad polypropylene-silicone oil, mica paper, and polytetrafluoroethylene-silicone oil capacitors discharged in a 100-ns, 1-kA pulse with a pulse repetition frequency of 1 kHz is presented. The test facility circuit, diagnostic parameters, and the preliminary test schedule are outlined as a basis for discussion of the observed failure locations and proposed failure mechanisms. Most of the test data and discussion presented involves the polypropylene-silicone oil units

  19. Study on a self diagnostic monitoring system for an air-operated valve: development of a fault library

    International Nuclear Information System (INIS)

    Chai, Jang Bom; Kim, Yun Chul; Kim, Woo Shik; Cho, Hang Duke

    2004-01-01

    In the interest of nuclear power plant safety, a Self-Diagnostic Monitoring System (SDMS) is needed to monitor defects in safety-related components. An Air-Operated Valve (AOV) is one of the components to be monitored since the failure of its operation could potentially have catastrophic consequences. In this paper, a model of the AOV is developed with the parameters that affect the operational characteristics. The model is useful for both understanding the operation and correlating parameters and defects. Various defects are introduced in the experiments to construct a fault library, which will be used in a pattern recognition approach. Finally, the validity of the fault library is examined

  20. The development of a diagnostic and monitoring system for vibrating pipe branches

    International Nuclear Information System (INIS)

    Tanaka, Toshio; Suzuki, Shigeki; Nekomoto, Yoshitsugu; Tanaka, Mamoru

    1994-01-01

    This paper deals with a diagnostic and monitoring system for assessing the integrity of pipe branches, during the operation of the nuclear power plant. This system have been developed under the concept of ''easy to use without any sophisticated analysis'' and ''portable''. The accuracy of the diagnosis is based on the model optimization subsystem, which automatically modifies the numerical vibration model so as to fit its natural frequency to the actual natural frequency. The information obtained by this system may be reflected to a maintenance program of the plant to assure more reliable operation of the plant. (orig.)

  1. Monitoring and diagnostic system of fission product transport and release in nuclear power plants

    International Nuclear Information System (INIS)

    Kodaira, H.; Kondo, S.; Togo, Y.

    1983-01-01

    A monitoring and diagnostic system (MADS) of fission product (FP) transport and release in nuclear power plants (NPPs) is proposed and the conceptual design for MADS is studied. A MADS can be described in the most general way as a computer-based information processing system which takes in plant data, processes it and displays the results to the NPP's operating crew. A major concern for MADS is, however, not to evaluate general plant dynamics, but to monitor the distribution of whole radioactive materials such as FP, and to diagnose the plant state in the view of FP transport during the NPP's lifetime. Several functions demanded of MADS are: (a) during normal operation, to certify the fuel integrity and the effectiveness of the purification systems, (b) in an unusual event, to identify the event and to monitor the amount of FP release with accuracy, and (c) in case of a rare occurrence, to estimate the maximum potential release

  2. Radioactivity monitor for high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Reeve, D.R.; Crozier, A.

    1977-01-01

    The coupling of a homogeneous radioactivity monitor to a liquid chromatograph involves compromises between the sensitivity of the monitor and the resolution and speed of analysis of the chromatograph. The theoretical relationships between these parameters are considered and expressions derived which make it possible to calculate suitable monitor operating conditions for most types of high-performance liquid chromatography

  3. Performance monitoring for brain-computer-interface actions.

    Science.gov (United States)

    Schurger, Aaron; Gale, Steven; Gozel, Olivia; Blanke, Olaf

    2017-02-01

    When presented with a difficult perceptual decision, human observers are able to make metacognitive judgements of subjective certainty. Such judgements can be made independently of and prior to any overt response to a sensory stimulus, presumably via internal monitoring. Retrospective judgements about one's own task performance, on the other hand, require first that the subject perform a task and thus could potentially be made based on motor processes, proprioceptive, and other sensory feedback rather than internal monitoring. With this dichotomy in mind, we set out to study performance monitoring using a brain-computer interface (BCI), with which subjects could voluntarily perform an action - moving a cursor on a computer screen - without any movement of the body, and thus without somatosensory feedback. Real-time visual feedback was available to subjects during training, but not during the experiment where the true final position of the cursor was only revealed after the subject had estimated where s/he thought it had ended up after 6s of BCI-based cursor control. During the first half of the experiment subjects based their assessments primarily on the prior probability of the end position of the cursor on previous trials. However, during the second half of the experiment subjects' judgements moved significantly closer to the true end position of the cursor, and away from the prior. This suggests that subjects can monitor task performance when the task is performed without overt movement of the body. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Multipronged diagnostic approaches for monitoring the treatment of Brucella abortus infected patient: a case report

    Directory of Open Access Journals (Sweden)

    Rajeswari Shome

    2015-07-01

    Full Text Available Brucellosis caused by Brucella species is readily transmissible to humans, causing acute febrile illness and undulant fever which may progress to a more chronic form and can also produce serious complications affecting the musculoskeletal, cardiovascular, and central nervous systems. A veterinary livestock inspector presented to the institute with symptoms of intermittent fever, pain involving muscles and joints, loss of weight, anxiety and weakness for about three months has been investigated. The isolation, serological tests and PCR were performed for diagnosis of brucellosis. Based on history of constant professional association with animals, characteristic symptoms, hematological and biochemical, multiple serological and PCR assay results, the patient was diagnosed as brucellosis. Detection of Brucella abortus directly in the clinical samples by gel based PCRs were highly useful for diagnosis and monitoring of treatment. This diagnostic protocol will facilitate in a simple way to map major Brucella species infecting humans in a geographical region.

  5. Breast cysts in adolescents - diagnostics, monitoring, treatment

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowska, A; Brzewski, M [Department of Paediatric Radiology of the Medical University of Warsaw, Warsaw (Poland); Grajewska-Ferens, M [Department of Paediatrics and Endocrinology of the Medical University of Warsaw, Warsaw (Poland)

    2011-07-01

    Background: The aim of the paper was the US evaluation of hormonal disorders and treatment results in adolescent girls and boys with breast cysts. Material/Methods: In the years 2001 - 2009, US examination of the breast was performed in 427 children aged 10 - 18 years, with clinically suspected breast pathologies. The indications for US examination typically included pain, breast swelling and a palpable tumor. The US examination was performed using a 7 - 12 MHz linear transducer. Results: Breast cysts were found in 42 children: 36 adolescent girls and 6 boys with gynaecomastia. Infected cysts were found in 35 children. The cysts ranged in size from 5 mm to 30 mm. In 5 of the girls, large cysts were treated by an incision and drainage, and in all the children with infected cysts, antibiotic therapy was used. Hormonal disorders were found in 30 girls. A follow-up examination was performed, and the observation time varied from 1/12 to 2 years. The cysts disappeared completely in 30 children. Hormonal therapy was introduced in 5 girls. Conclusions: Breast cysts found in US examinations are indications for check-up examinations including endocrinological diagnostics and, if the cyst is persistent, possibly for hormonal treatment. (authors)

  6. Psychophysical analysis of monitor display functions affecting observer diagnostic performance of CT image on liquid crystal display monitors

    International Nuclear Information System (INIS)

    Yamaguchi, M.; Fujita, H.; Asai, Y.; Uemura, M.; Ookura, Y.; Matsumoto, M.; Johkoh, T.

    2005-01-01

    The aim of the present study was to propose suitable display functions for CT image representation on liquid crystal display (LCD) monitors by analyzing the characteristics of the monitor's typical display functions using psychophysical analysis. The luminance of the LCD monitor was adjusted to a maximum of 275 cd/m 2 and 480 cd/m 2 . Three types of postcalibrated display functions (i.e., GSDF, CIELAB, and Exponential γ 2.2) were evaluated. Luminance calculation of a new grayscale test pattern (NGTP) was done for the conversion of the digital driving level (DDL) into the CT value. The psychophysical gradient δ of display functions for the CT value was evaluated and compared via statistical analysis. The δ value of GSDF and CIE decreased exponentially; however, the δ value of Exponential γ 2.2 showed a convex curve with a peak at a specific point. There was a statistically significant difference among the δ values of the three types of display functions on the 480 cd/m 2 maximum via Kruskal Wallis test (P<0.001). The GSDF was suitable for observation of abdominal and lung CT images; however, the display function combined the Exponential γ 2.2 and the GSDF functions and was ideal for observation of brain CT images by psychophysical analysis. (orig.)

  7. GPS Civil Monitoring Performance Specification

    Science.gov (United States)

    2009-02-10

    This Civil Monitoring Performance Specification (CMPS) is published and maintained at : the direction of the Program Manager for Civil Applications, Global Positioning Systems : Wing (GPSW). The purpose of this document is to provide a comprehensive ...

  8. Electrical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Issouf Fofana

    2016-08-01

    Full Text Available The condition of the internal cellulosic paper and oil insulation are of concern for the performance of power transformers. Over the years, a number of methods have been developed to diagnose and monitor the degradation/aging of the transformer internal insulation system. Some of this degradation/aging can be assessed from electrical responses. Currently there are a variety of electrical-based diagnostic techniques available for insulation condition monitoring of power transformers. In most cases, the electrical signals being monitored are due to mechanical or electric changes caused by physical changes in resistivity, inductance or capacitance, moisture, contamination or aging by-products in the insulation. This paper presents a description of commonly used and modern electrical-based diagnostic techniques along with their interpretation schemes.

  9. Examining Big Brother's Purpose for Using Electronic Performance Monitoring

    Science.gov (United States)

    Bartels, Lynn K.; Nordstrom, Cynthia R.

    2012-01-01

    We examined whether the reason offered for electronic performance monitoring (EPM) influenced participants' performance, stress, motivation, and satisfaction. Participants performed a data-entry task in one of five experimental conditions. In one condition, participants were not electronically monitored. In the remaining conditions, participants…

  10. Review of diagnostics for next generation linear accelerators

    CERN Document Server

    Ross, M

    2001-01-01

    New electron linac designs incorporate substantial advances in critical beam parameters such as beam loading and bunch length and will require new levels of performance in stability and phase space control. In the coming decade, e- (and e+) linacs will be built for a high power linear collider (TESLA, CLIC, JLC/NLC), for fourth generation X-ray sources (TESLA FEL, LCLS, Spring 8 FEL) and for basic accelerator research and development (Orion). Each project assumes significant instrumentation performance advances across a wide front. This review will focus on basic diagnostics for beam position and phase space monitoring. Research and development efforts aimed at high precision multi-bunch beam position monitors, transverse and longitudinal profile monitors and timing systems will be described.

  11. Diagnostic value of combined esophageal multi-channel intraluminal impedance and pH monitoring for gastroesophageal reflux in critically ill patients

    Directory of Open Access Journals (Sweden)

    Yi JIN

    2016-06-01

    Full Text Available Objective  To compare the diagnostic value of using 24-hour combined esophageal multichannel intraluminal impedance and pH monitoring (MII-pH in the diagnosis of gastro-esophageal reflux (GER and pH monitoring alone in critically ill patients. Methods  A prospective observational study was performed including 116 critically ill adult patients admitted to ICU of Peking Haidian Hospital from Jul. 2013 to Dec. 2014. All the patients underwent 24-hour combined MⅡ-pH monitoring. GER episodes were recorded and its pH was recorded (acidic, weakly acidic and weakly alkaline and its composition was recorded (liquid, mixed and gas reflux. The results of the MⅡ-pH and the pH were monitored and compared. The demographic characteristics and clinical information were recorded. Results  MⅡ-pH was monitored for 5024 episodes of GER in 115 of 116(99.1% patients, with a mean of 43.28±3.96 episodes per patient (median, 34 episodes; range, 0-196 episodes. The pH monitoring detected 1868 episodes (100% acid in only 54 of 116(46.6% patients, with a mean of 7.66±1.65 episodes per patient (median, 0 episodes; range, 0-81 episodes. The number of episode of all reflux and liquid reflux diagnosed by pH monitoring alone was less than those diagnosed by MⅡ-pH monitoring (P=0.000, and there was no correlation in the episodes number of all reflux and liquid reflux between the two techniques (r=0.119, 0.231. Only a moderate correlation was found in the number of episodes of acidic reflux between the two techniques (r=0.656. Conclusion  MⅡ-pH monitoring is more sensitive than pH monitoring alone for establishing the diagnosis of GER. DOI: 10.11855/j.issn.0577-7402.2016.05.12

  12. Expert monitoring and verbal feedback as sources of performance pressure.

    Science.gov (United States)

    Buchanan, John J; Park, Inchon; Chen, Jing; Mehta, Ranjana K; McCulloch, Austin; Rhee, Joohyun; Wright, David L

    2018-05-01

    The influence of monitoring-pressure and verbal feedback on the performance of the intrinsically stable bimanual coordination patterns of in-phase and anti-phase was examined. The two bimanual patterns were produced under three conditions: 1) no-monitoring, 2) monitoring-pressure (viewed by experts), and 3) monitoring-pressure (viewed by experts) combined with verbal feedback emphasizing poor performance. The bimanual patterns were produced at self-paced movement frequencies. Anti-phase coordination was always less stable than in-phase coordination across all three conditions. When performed under conditions 2 and 3, both bimanual patterns were performed with less variability in relative phase across a wide range of self-paced movement frequencies compared to the no-monitoring condition. Thus, monitoring-pressure resulted in performance stabilization rather than degradation and the presence of verbal feedback had no impact on the influence of monitoring pressure. The current findings are inconsistent with the predictions of explicit monitoring theory; however, the findings are consistent with studies that have revealed increased stability for the system's intrinsic dynamics as a result of attentional focus and intentional control. The results are discussed within the contexts of the dynamic pattern theory of coordination, explicit monitoring theory, and action-focused theories as explanations for choking under pressure. Copyright © 2018. Published by Elsevier B.V.

  13. Diagnostic Performance on Low Dose Computed Tomography For Acute Appendicitis Among Attending and Resident Radiologists

    International Nuclear Information System (INIS)

    Chang, Chih-Chen; Wong, Yon-Cheong; Wu, Cheng-Hsien; Chen, Huan-Wu; Wang, Li-Jen; Lee, Yu-Hsien; Wu, Patricia Wanping; Irama, Wiwan; Chen, Wei Yuan; Chang, Chee-Jen

    2016-01-01

    Low-dose computed tomography (LDCT) techniques can reduce exposure to radiation. Several previous studies have shown that radiation dose reduction in LDCT does not decrease the diagnostic performance for appendicitis among attending radiologists. But, the LDCT diagnostic performance for acute appendicitis in radiology residents with variable training levels has not been well discussed. To compare inter-observer and intra-observer differences of diagnostic performance on non-enhanced LDCT (NE-LDCT) and contrast-enhanced standard dose CT (CE-SDCT) for acute appendicitis among attending and resident radiologists. This retrospective study included 101 patients with suspected acute appendicitis who underwent NE-LDCT and CE-SDCT. The CT examinations were interpreted and recorded on a five-point scale independently by three attending radiologists and three residents with 4, 1 and 1 years of training. Diagnostic performance for acute appendicitis of all readers on both examinations was represented by area under receiver operating characteristic (ROC) curves. Inter-observer and intra-observer AUC values were compared using Jackknife FROC software on both modalities. The diagnostic accuracy of each reader on NE-LDCT was compared with body mass index (BMI) subgroups and noise using independent T test. Diagnostic performances for acute appendicitis were not statistically different for attending radiologists at both examinations. Better performance was noted on the CE-SDCT with a borderline significant difference (P = 0.05) for senior radiology resident. No statistical difference of AUC values was observed between attending radiologists and fourth year resident on both examinations. Statistically signifi@@cant differences of AUC values were observed between attending radiologists and first year residents (P = 0.001 ~ 0.018) on NE-LDCT. Diagnostic accuracies of acute appendicitis on NE-LDCT for each reader were not significantly related to BMI or noise. Attending radiologists

  14. Systems engineering approach towards performance monitoring of emergency diesel generator

    International Nuclear Information System (INIS)

    Nurhayati Ramli; Lee, Y.K.

    2013-01-01

    Full-text: Systems engineering is an interdisciplinary approach and means to enable the realization of successful systems. In this study, systems engineering approach towards the performance monitoring of Emergency Diesel Generator (EDG) is presented. Performance monitoring is part and parcel of predictive maintenance where the systems and components conditions can be detected before they result into failures. In an effort to identify the proposal for addressing performance monitoring, the EDG boundary has been defined. Based on the Probabilistic Safety Analysis (PSA) results and industry operating experiences, the most critical component is identified. This paper proposed a systems engineering concept development framework towards EDG performance monitoring. The expected output of this study is that the EDG reliability can be improved by the performance monitoring alternatives through the systems engineering concept development effort. (author)

  15. Cloud-based CT dose monitoring using the DICOM-structured report. Fully automated analysis in regard to national diagnostic reference levels

    International Nuclear Information System (INIS)

    Boos, J.; Rubbert, C.; Heusch, P.; Lanzman, R.S.; Aissa, J.; Antoch, G.; Kroepil, P.

    2016-01-01

    To implement automated CT dose data monitoring using the DICOM-Structured Report (DICOM-SR) in order to monitor dose-related CT data in regard to national diagnostic reference levels (DRLs). Materials and Methods: We used a novel in-house co-developed software tool based on the DICOM-SR to automatically monitor dose-related data from CT examinations. The DICOM-SR for each CT examination performed between 09/2011 and 03/2015 was automatically anonymized and sent from the CT scanners to a cloud server. Data was automatically analyzed in accordance with body region, patient age and corresponding DRL for volumetric computed tomography dose index (CTDI vol ) and dose length product (DLP). Results: Data of 36 523 examinations (131 527 scan series) performed on three different CT scanners and one PET/CT were analyzed. The overall mean CTDI vol and DLP were 51.3 % and 52.8 % of the national DRLs, respectively. CTDI vol and DLP reached 43.8 % and 43.1 % for abdominal CT (n = 10 590), 66.6 % and 69.6 % for cranial CT (n = 16 098) and 37.8 % and 44.0 % for chest CT (n = 10 387) of the compared national DRLs, respectively. Overall, the CTDI vol exceeded national DRLs in 1.9 % of the examinations, while the DLP exceeded national DRLs in 2.9 % of the examinations. Between different CT protocols of the same body region, radiation exposure varied up to 50 % of the DRLs. Conclusion: The implemented cloud-based CT dose monitoring based on the DICOM-SR enables automated benchmarking in regard to national DRLs. Overall the local dose exposure from CT reached approximately 50 % of these DRLs indicating that DRL actualization as well as protocol-specific DRLs are desirable. The cloud-based approach enables multi-center dose monitoring and offers great potential to further optimize radiation exposure in radiological departments.

  16. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    Science.gov (United States)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  17. Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.

    Science.gov (United States)

    Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew

    2012-12-01

    Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.

  18. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    International Nuclear Information System (INIS)

    Marchevsky, M; Wang, X; Sabbi, G; Prestemon, S

    2013-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb3Sn quadrupole HQ01, we show how acoustic data is connected with voltage instabilities measured simultaneously in the magnet windings during provoked extractions and current ramps to quench. Instrumentation and data analysis techniques for acoustic sensing are reviewed. (author)

  19. Acoustic detection in superconducting magnets for performance characterization and diagnostics

    CERN Document Server

    Marchevsky, M.; Sabbi, G.; Prestemon, S.

    2013-01-01

    Quench diagnostics in superconducting accelerator magnets is essential for understanding performance limitations and improving magnet design. Applicability of the conventional quench diagnostics methods such as voltage taps or quench antennas is limited for long magnets or complex winding geometries, and alternative approaches are desirable. Here, we discuss acoustic sensing technique for detecting mechanical vibrations in superconducting magnets. Using LARP high-field Nb$_{3}$Sn quadrupole HQ01 [1], we show how acoustic data is connected with voltage instabilities measured simultaneously in the magnet windings during provoked extractions and current ramps to quench. Instrumentation and data analysis techniques for acoustic sensing are reviewed.

  20. Advances in point-of-care technologies for molecular diagnostics.

    Science.gov (United States)

    Zarei, Mohammad

    2017-12-15

    Advances in miniaturization, nanotechnology, and microfluidics, along with developments in cloud-connected point-of-care (POC) diagnostics technologies are pushing the frontiers of POC devices toward low-cost, user-friendly, and enhanced sensitivity molecular-level diagnostics. The combination of various bio-sensing platforms within smartphone-integrated electronic readers provides accurate on-site and on-time diagnostics based on various types of chemical and biological targets. Further, 3D printing technology shows a huge potential toward fabrication and improving the performance of POC devices. Integration of skin-like flexible sensors with wireless communication technology creates a unique opportunity for continuous, real-time monitoring of patients for both preventative healthcare and during disease outbreaks. Here, we review recent developments and advances in POC technologies and describe how these advances enhance the performance of POC platforms. Also, this review describes challenges, directions, and future trends on application of emerging technologies in POC diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A systematic review of the diagnostic performance of orthopedic physical examination tests of the hip.

    Science.gov (United States)

    Rahman, Labib Ataur; Adie, Sam; Naylor, Justine Maree; Mittal, Rajat; So, Sarah; Harris, Ian Andrew

    2013-08-30

    Previous reviews of the diagnostic performances of physical tests of the hip in orthopedics have drawn limited conclusions because of the low to moderate quality of primary studies published in the literature. This systematic review aims to build on these reviews by assessing a broad range of hip pathologies, and employing a more selective approach to the inclusion of studies in order to accurately gauge diagnostic performance for the purposes of making recommendations for clinical practice and future research. It specifically identifies tests which demonstrate strong and moderate diagnostic performance. A systematic search of Medline, Embase, Embase Classic and CINAHL was conducted to identify studies of hip tests. Our selection criteria included an analysis of internal and external validity. We reported diagnostic performance in terms of sensitivity, specificity, predictive values and likelihood ratios. Likelihood ratios were used to identify tests with strong and moderate diagnostic utility. Only a small proportion of tests reported in the literature have been assessed in methodologically valid primary studies. 16 studies were included in our review, producing 56 independent test-pathology combinations. Two tests demonstrated strong clinical utility, the patellar-pubic percussion test for excluding radiologically occult hip fractures (negative LR 0.05, 95% Confidence Interval [CI] 0.03-0.08) and the hip abduction sign for diagnosing sarcoglycanopathies in patients with known muscular dystrophies (positive LR 34.29, 95% CI 10.97-122.30). Fifteen tests demonstrated moderate diagnostic utility for diagnosing and/or excluding hip fractures, symptomatic osteoarthritis and loosening of components post-total hip arthroplasty. We have identified a number of tests demonstrating strong and moderate diagnostic performance. These findings must be viewed with caution as there are concerns over the methodological quality of the primary studies from which we have extracted our

  2. POTENTIALITIES OF DIAGNOSTICS AND DIFFERENTIAL DIAGNOSTICS OF STOMACH DISEASES BY MEANS OF USAGE OF HIGH-PERFORMANCE BLOOD SERUM LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    O.P. Alexeeva

    2008-12-01

    Full Text Available 62 patients with the endoscopically and morphologicallyverified diagnosis of the chronic gastritis, 89 patients with the morphologically verified diagnosis of stomach cancer and 43 healthy persons ages 23 to 54 years have been examined. Potentialities of the usage of high-performance blood serum liquid chromatography have been studied for the purpose of diagnostics and differential diagnostics of chronic gastritis and stomach cancer. Blood serum driedextract was investigated by means of"Milichrome A02"chromatograph (Novosibirsk, "Econova" joint-stock company. The chromatograms were treated by the multivahate cluster analysis with the formation of pathologic three-dimensional characteristic state notably differed from the healthy human image. Diagnostic sensitivity of chronic gastritis and stomach cancer acounts for accordingly 92% and 96%. Diagnostic accuracy of the method comes to 94%.

  3. Multidimensional Monitoring of Recovery Status and Implications for Performance.

    Science.gov (United States)

    Heidari, Jahan; Beckmann, Jürgen; Bertollo, Maurizio; Brink, Michel; Kallus, Wolfgang; Robazza, Claudio; Kellmann, Michael

    2018-03-15

    Monitoring of recovery in the context of athletic performance has gained significant importance during recent years. As a systematic process of data collection and evaluation, the monitoring of recovery can be implemented for various purposes. It may aid to prevent negative outcomes of training or competition, such as underrecovery, overtraining, or injuries. Further, it aims at establishing routines and strategies necessary to guarantee athletes' readiness for performance by restoring their depleted resources. Comprehensive monitoring of recovery ideally encompasses a multidimensional approach, thereby considering biological, psychological, and social monitoring methods. From a biological perspective, physiological (e.g., cardiac parameters), biochemical (e.g., creatine kinase), hormonal (e.g., salivary cortisol) and immunological (e.g., immunoglobulin A) markers can be taken into account to operationalize training loads and recovery needs. Psychological approaches suggest the application of validated and reliable psychometric questionnaires (e.g., Recovery-Stress Questionnaire for Athletes) to measure a subjective perception of recovery as well as the subjective degree of training- or competition-induced fatigue. Social aspects also play a role in performance monitoring and may hence provide essential performance-related information. The implementation of a monitoring routine within athletic environments represents a continuous process which functions as an effective addition to training and depends on a range of conditions (e.g., organizational regulations, commitment of athletes). Current research in the field of monitoring aims at establishing individualized monitoring regimes that are referring to intraindividual reference values with the help of innovative technological devices.

  4. Monitors for the surveillance of NPP components

    International Nuclear Information System (INIS)

    Giera, H.D.; Grabner, A.; Hessel, G.; Koeppen, H.E.; Liewers, P.; Schumann, P.; Weiss, F.P.; Kunze, U.; Pfeiffer, G.

    1985-01-01

    Noise diagnostics have reached a level where it is possible and efficient to integrate this method as far as possible into the control and safety system of the NPP. The communication between the noise diagnostic system and the plant operator is the main problem of integration. It is necessary to refine the diagnostic results in such a manner that the operator can use them without being skilled in noise analysis respectively without contacting a noise specialist. Moreover, in this way the noise specialist can be released from routine surveillance. For selected processes which have already intensively been investigated because of their inherent risk this can be achieved by means of autonomously working monitors. Independently the monitors perform signal processing and diagnosis. In general this means that they classify the technical condition of the monitored component into one of the two categories: ''normal'' or ''anomalous''. The result will be annunciated to the plant operator who will in the first step of the development contact the noise specialist only if anomalies have occurred in order to clarify the cause. At the NPP ''Bruno Leuschner'' Greifswald, three hardware monitors for loose parts detection, control rod surveillance and main coolant pump diagnosis are being tested. Additionally a so-called software monitor for diagnosing the pressure vessel vibrations is in preparation. The techniques and the hardware used for the monitors as well as planned further improvements of the integration of noise diagnostics into the control and safety system are discussed in this paper. (author)

  5. Regression models of reactor diagnostic signals

    International Nuclear Information System (INIS)

    Vavrin, J.

    1989-01-01

    The application is described of an autoregression model as the simplest regression model of diagnostic signals in experimental analysis of diagnostic systems, in in-service monitoring of normal and anomalous conditions and their diagnostics. The method of diagnostics is described using a regression type diagnostic data base and regression spectral diagnostics. The diagnostics is described of neutron noise signals from anomalous modes in the experimental fuel assembly of a reactor. (author)

  6. EMBEDDED SYSTEMS FOR VIBRATION MONITORING

    Directory of Open Access Journals (Sweden)

    Miloš Milovančević

    2014-08-01

    Full Text Available The purpose of the research presented in this paper is the development of the optimal micro configuration for vibration monitoring of pumping aggregate, based on Microchip’s microcontroller (MC. Hardware used is 10-bit MC, upgraded with 12/bit A/D converter. Software for acquisition and data analysis is optimized for testing turbo pumps with rotation speed up to 2000 rpm. This software limitation is set for automatic diagnostics and for individual and manual vibro-diagnostic; the only limitation is set by accelerometer performance. The authors have performed numerous measurements on a wide range of turbo aggregates for establishing the operational condition of pumping aggregates.

  7. A Diagnostic and Predictive Framework for Wind Turbine Drive Train Monitoring

    DEFF Research Database (Denmark)

    Bach-Andersen, Martin

    Vast amount of data are collected minute by minute from wind turbines around the world. This thesis represents a focused research effort into discovering new ways of processing these data streams in order to gain insights which can be used to lower the maintenance costs of wind turbines and increase......, early fault identification based on analysis of complex vibration patterns which is a domain previously reserved for human experts, is shown to be solved with high accuracy using deep learning architecture strained in a fully supervised sense from the data collected in a large scale wind turbine...... monitoring platform. The research shows a way towards a fully automatized data-driven wind turbine diagnostic processing system that is highly scalable and requires little or no feature engineering and system modeling....

  8. Condenser performance monitoring and cleaning

    International Nuclear Information System (INIS)

    Walden, J.V.

    1998-01-01

    The main condenser at Ginna Station was retubed from admiralty brass to 316 stainless steel. A condenser performance monitoring spreadsheet was developed using EPRI guidelines after fouling was discovered. PEPSE computer models were used to determine the power loss and confirm the spreadsheet results. Cleaning of the condenser was performed using plastic scrubbers. Condenser performance improved dramatically following the cleaning. PEPSE, condenser spreadsheet performance, and actual observed plant data correlated well together. The fouling mechanism was determined to be a common lake bacteria and fungus growth which was combined with silt. Chlorination of the circulating water system at the allowable limits is keeping the biofouling under control

  9. Detailed Performance Assessment for the ITER ECE Diagnostic

    Science.gov (United States)

    Rowan, W.; Austin, M.; Houshmandyar, S.; Phillips, P.; Beno, J.; Bryant, A.; Ouroua, A.; Weeks, D.; Hubbard, A.; Taylor, G.

    2017-10-01

    One of the primary diagnostics for electron temperature (Te) measurement on ITER is based on the detection of electron cyclotron emission (ECE) Here we describe the predicted performance of the newly completed ECE diagnostic design by quantitatively following the emission from the plasma to the instruments and including the calibration method to assess accuracy. Operation of the diagnostic at 5.3 T is the main interest here but critical features of the emission spectra for 2.65 T and 1.8 T will be described. ECE will be collected by two very similar optical systems: one a radial view, the other an oblique view. Both measurements are used for Te while the oblique view also allows detection of non-thermal distortion in the electron distribution. An in-vacuum calibration source is included in the front end of each view to calibrate out the effect of any degradation of in-vessel optics. Following collection, the emission is split into orthogonal polarizations and transmitted to the detection instruments via waveguides filled with dry nitrogen, a choice that simplifies construction and analysis. Near the instruments, a switchyard is used to select which polarization and view is detected by each instrument. The design for the radiometer used for 5.3 T will be described in detail. Supported by PPPL/US-DA via subcontract S013464-H to UT Austin.

  10. Building Performance Optimization while Empowering Occupants Toward Environmentally Sustainable Behavior through Continuous Monitoring and Diagnostics

    Science.gov (United States)

    2016-12-01

    Federal Energy Management Program FM Facility Manager GHG Green House Gases HASP Health and Safety Plan HVAC Heating Ventilation and... workplace energy efficiency enhancement by the DOD personnel. 2.1.2 ID-F Intelligent Dashboards for Facility Managers Creation of the Base Building...demonstration project. The first technology, ‘ID-F,’ targets building facility managers and allows real time diagnostics for BAS systems with features

  11. Environmental sensing and combustion diagnostics

    International Nuclear Information System (INIS)

    Santoleri, J.J.

    1991-01-01

    This book contains proceedings of Environmental Sensing and Combustion Diagnostics. Topics covered include: Incineration Systems Applications, Permitting, And Monitoring Overview; Infrared Techniques Applied to Incineration Systems; Continuous Emission Monitors; Analyzers and Sensors for Process Control And Environmental Monitoring

  12. Gearbox vibration diagnostic analyzer

    Science.gov (United States)

    1992-01-01

    This report describes the Gearbox Vibration Diagnostic Analyzer installed in the NASA Lewis Research Center's 500 HP Helicopter Transmission Test Stand to monitor gearbox testing. The vibration of the gearbox is analyzed using diagnostic algorithms to calculate a parameter indicating damaged components.

  13. Cooled Beam Diagnostics on LEIR

    CERN Document Server

    Tranquille, G; Carli, C; Chanel, M; Prieto, V; Sautier, R; Tan, J

    2008-01-01

    Electron cooling is central in the preparation of dense bunches of lead beams for the LHC. Ion beam pulses from the LINAC3 are transformed into short highbrightness bunches using multi-turn injection, cooling and accumulation in the Low Energy Ion Ring, LEIR [1]. The cooling process must therefore be continuously monitored in order to guarantee that the lead ions have the required characteristics in terms of beam size and momentum spread. In LEIR a number of systems have been developed to perform these measurements. These include Schottky diagnostics, ionisation profile monitors and scrapers. Along with their associated acquisition and analysis software packages these instruments have proved to be invaluable for the optimisation of the electron cooler.

  14. Strategies of performance self-monitoring in automotive production.

    Science.gov (United States)

    Faye, Hélène; Falzon, Pierre

    2009-09-01

    Production in the automotive industry, based on assembly line work, is now characterized by lean manufacturing and customization. This results in greater flexibility and increased quality demands, including worker performance self-monitoring. The objectives of this study are to refine the concept of performance self-monitoring and to characterize the strategies developed by operators to achieve it. Data were collected based on the method of individual auto-confrontation, consisting of two steps: eleven assembly-line operators of a French automotive company were individually observed and video-taped while they were working; an interview then allowed each operator to discuss his/her activity based on the video-tape. This study expands the concept of performance self-monitoring by highlighting three types of strategies directly oriented toward quality: prevention, feedback control and control action strategies.

  15. Distributed Rocket Engine Testing Health Monitoring System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The on-ground and Distributed Rocket Engine Testing Health Monitoring System (DiRETHMS) provides a system architecture and software tools for performing diagnostics...

  16. Behavioral and electrophysiological evidence of enhanced performance monitoring in meditators

    NARCIS (Netherlands)

    Andreu, C.I.; Moënne-Loccoz, C.; López, V.; Slagter, H.A.; Franken, I.H.A.; Cosmelli, D.

    2017-01-01

    Performance monitoring—the ability to monitor ongoing performance to detect and correct errors—is a core component of cognitive control. Impairments in performance monitoring have been associated with several psychiatric disorders, including attention deficit hyperactivity disorder and substance use

  17. Simultaneous recording of EEG and electromyographic polygraphy increases the diagnostic yield of video-EEG monitoring.

    Science.gov (United States)

    Hill, Aron T; Briggs, Belinda A; Seneviratne, Udaya

    2014-06-01

    To investigate the usefulness of adjunctive electromyographic (EMG) polygraphy in the diagnosis of clinical events captured during long-term video-EEG monitoring. A total of 40 patients (21 women, 19 men) aged between 19 and 72 years (mean 43) investigated using video-EEG monitoring were studied. Electromyographic activity was simultaneously recorded with EEG in four patients selected on clinical grounds. In these patients, surface EMG electrodes were placed over muscles suspected to be activated during a typical clinical event. Of the 40 patients investigated, 24 (60%) were given a diagnosis, whereas 16 (40%) remained undiagnosed. All four patients receiving adjunctive EMG polygraphy obtained a diagnosis, with three of these diagnoses being exclusively reliant on the EMG recordings. Specifically, one patient was diagnosed with propriospinal myoclonus, another patient was diagnosed with facio-mandibular myoclonus, and a third patient was found to have bruxism and periodic leg movements of sleep. The information obtained from surface EMG recordings aided the diagnosis of clinical events captured during video-EEG monitoring in 7.5% of the total cohort. This study suggests that EEG-EMG polygraphy may be used as a technique of improving the diagnostic yield of video-EEG monitoring in selected cases.

  18. On-Line Monitoring and Diagnostics of the Integrity of Nuclear Plant Steam Generators and Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Belle R. Upadhyaya; J. Wesley Hines

    2004-09-27

    Integrity monitoring and flaw diagnostics of flat beams and tubular structures was investigated in this research task using guided acoustic signals. A piezo-sensor suite was deployed to activate and collect Lamb wave signals that propagate along metallic specimens. The dispersion curves of Lamb waves along plate and tubular structures are generated through numerical analysis. Several advanced techniques were explored to extract representative features from acoustic time series. Among them, the Hilbert-Huang transform (HHT) is a recently developed technique for the analysis of non-linear and transient signals. A moving window method was introduced to generate the local peak characters from acoustic time series, and a zooming window technique was developed to localize the structural flaws. The time-frequency analysis and pattern recognition techniques were combined for classifying structural defects in brass tubes. Several types of flaws in brass tubes were tested, both in the air and in water. The techniques also proved to be effective under background/process noise. A detailed theoretical analysis of Lamb wave propagation was performed and simulations were carried out using the finite element software system ABAQUS. This analytical study confirmed the behavior of the acoustic signals acquired from the experimental studies. The report presents the background the analysis of acoustic signals acquired from piezo-electric transducers for structural defect monitoring. A comparison of the use of time-frequency techniques, including the Hilbert-Huang transform, is presented. The report presents the theoretical study of Lamb wave propagation in flat beams and tubular structures, and the need for mode separation in order to effectively perform defect diagnosis. The results of an extensive experimental study of detection, location, and isolation of structural defects in flat aluminum beams and brass tubes are presented. The results of this research show the feasibility of on

  19. On-Line Monitoring and Diagnostics of the Integrity of Nuclear Plant Steam Generators and Heat Exchangers

    International Nuclear Information System (INIS)

    Upadhyaya, Belle R.; Hines, J. Wesley

    2004-01-01

    Integrity monitoring and flaw diagnostics of flat beams and tubular structures was investigated in this research task using guided acoustic signals. A piezo-sensor suite was deployed to activate and collect Lamb wave signals that propagate along metallic specimens. The dispersion curves of Lamb waves along plate and tubular structures are generated through numerical analysis. Several advanced techniques were explored to extract representative features from acoustic time series. Among them, the Hilbert-Huang transform (HHT) is a recently developed technique for the analysis of non-linear and transient signals. A moving window method was introduced to generate the local peak characters from acoustic time series, and a zooming window technique was developed to localize the structural flaws. The time-frequency analysis and pattern recognition techniques were combined for classifying structural defects in brass tubes. Several types of flaws in brass tubes were tested, both in the air and in water. The techniques also proved to be effective under background/process noise. A detailed theoretical analysis of Lamb wave propagation was performed and simulations were carried out using the finite element software system ABAQUS. This analytical study confirmed the behavior of the acoustic signals acquired from the experimental studies. The report presents the background the analysis of acoustic signals acquired from piezo-electric transducers for structural defect monitoring. A comparison of the use of time-frequency techniques, including the Hilbert-Huang transform, is presented. The report presents the theoretical study of Lamb wave propagation in flat beams and tubular structures, and the need for mode separation in order to effectively perform defect diagnosis. The results of an extensive experimental study of detection, location, and isolation of structural defects in flat aluminum beams and brass tubes are presented. The results of this research show the feasibility of on

  20. Diagnostic performance of increased overjet in Class II division 1 malocclusion and incisor trauma.

    Science.gov (United States)

    Baccetti, Tiziano; Giuntini, Veronica; Vangelisti, Andrea; Darendeliler, M Ali; Franchi, Lorenzo

    2010-01-01

    The objectives of this study were: 1) to evaluate the associations between an increased overjet (IO) and other dentoskeletal characteristics of Class II division 1 malocclusions in the mixed dentition; 2) to assess whether Class II division 1 malocclusions or rather an increased overjet per se is a risk factor for upper incisor trauma (UIT). A sample of 900 mixed dentition subjects, was observed by clinical inspection, analysis of dental casts, and lateral cephalograms. The diagnostic performance of IO (overjet ≥ 7 mm) was evaluated in relation to other Class II dentoskeletal features (Class II molar and canine relationships, and skeletal Class II relationships). Secondly, the diagnostic performance of IO and of the other Class II dentoskeletal components was tested with regard to the prevalence of UIT. Diagnostic performance was assessed by odds ratio and positive likelihood ratio. The diagnostic performance of IO with regard to the other dentoskeletal components of Class II malocclusions was not significant. The only Class II features associated significantly with an increased risk of UIT was IO. When used as an isolated occlusal feature, IO is not a valid diagnostic indicator for Class II division 1 malocclusions. An increased overjet per se, and not Class II malocclusions, appears to be a significant risk factor for UIT. These findings recommend discrimination between clinical conditions showing an isolated IO from comprehensive Class II malocclusions during diagnosis, analysis of treatment outcomes, and evaluation of the risk of upper incisor trauma. Copyright © 2010 Società Italiana di Ortodonzia SIDO. Published by Elsevier Srl. All rights reserved.

  1. PC based diagnostic system for nitrogen production unit of HWP

    International Nuclear Information System (INIS)

    Lamba, D.S.; Rao, V.C.; Krishnan, S.; Kamaraj, T.; Krishnaswamy, C.

    1992-01-01

    The plant diagnostic system monitors the input data from local processing unit and tries to diagnose the cause of the failure. The system is a rule based application program that can perform tasks itself using fault tree model which displays the logical relationships between critical events and their possible ways occurrence, i.e. hardware failure, process faults and human error etc. Unit 37 Nitrogen Plant is taken as a prototype model for trying the plant diagnostics system. (author). 3 refs., 2 figs

  2. Fuel-motion diagnostics and cineradiography

    International Nuclear Information System (INIS)

    DeVolpi, A.

    1982-09-01

    Nuclear and non-nuclear applications of cineradiography are reviewed, with emphasis on diagnostic instrumentation for in-pile transient-reactor safety testing of nuclear fuel motion. The primary instrument for this purpose has been the fast-neutron hodoscope, which has achieved quantitative monitoring of time, location, mass, and velocity of fuel movement under the difficult conditions associated with transient-reactor experiments. Alternative diagnostic devices that have been developed have not matched the capabilities of the hodoscope. Other applications for the fuel-motion diagnostic apparatus are also evolving, including time-integrated radiography and direct time- and space-resolved fuel-pin power monitoring. Although only two reactors are now actively equipped with high-resolution fuel-motion diagnostic systems, studies and tests have been carried out in and for many other reactors

  3. 14 CFR 152.319 - Monitoring and reporting of program performance.

    Science.gov (United States)

    2010-01-01

    ... performance. 152.319 Section 152.319 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIRPORTS AIRPORT AID PROGRAM Accounting and Reporting Requirements § 152.319 Monitoring and reporting of program performance. (a) The sponsor or planning agency shall monitor performance...

  4. Runtime Performance Monitoring Tool for RTEMS System Software

    Science.gov (United States)

    Cho, B.; Kim, S.; Park, H.; Kim, H.; Choi, J.; Chae, D.; Lee, J.

    2007-08-01

    RTEMS is a commercial-grade real-time operating system that supports multi-processor computers. However, there are not many development tools for RTEMS. In this paper, we report new RTEMS-based runtime performance monitoring tool. We have implemented a light weight runtime monitoring task with an extension to the RTEMS APIs. Using our tool, software developers can verify various performance- related parameters during runtime. Our tool can be used during software development phase and in-orbit operation as well. Our implemented target agent is light weight and has small overhead using SpaceWire interface. Efforts to reduce overhead and to add other monitoring parameters are currently under research.

  5. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  6. Who can monitor the court interpreter's performance?

    DEFF Research Database (Denmark)

    Martinsen, Bodil

    2009-01-01

    and the conflict about her competence was negotiated. Because of this unusual constellation, combined with a multi-method approach, this single case study can shed some light on the question of the participants' ability to monitor the interpreter's performance. Legal professional users of interpreters tend......  Who can monitor the court interpreter's performance? Results of a case study This paper presents the results of a case study of an unusual interpreting event in a Danish courtroom setting. During the trial, the interpreter's non-normative performance was explicitly criticised by the audience...... are far less transparent for the legal participants than they normally assume. This problem, in turn, stresses the importance of a) the interpreter's competence and self-awareness and b) the use of check interpreters.  ...

  7. The JET neutron emission profile monitor

    International Nuclear Information System (INIS)

    Adams, J.M.; Syme, D.B.; Watkins, N.; Jarvis, O.N.; Sadler, G.J.

    1993-01-01

    This paper provides a technical description of the neutron emission profile monitor as used routinely at the Joint European Torus (JET), and includes representative examples of its operational capabilities. The primary function of this instrument is to measure the neutron emission as a function of both position and time in a poloidal (vertical along major radius) section through the torus. For the first time the spatially localised effects of sawteeth (magnetic relaxation phenomena) have been observed using a neutron diagnostic. The total (global) neutron emission can be obtained from the profile monitor data by performing a volume integral over the plasma; the absolute neutron emission rates agree with those obtained from the JET time-resolved neutron monitor to within ±15%. This was the first such instrument routinely in use on any tokamak. It provides unique data which are independent of all other diagnostic measurements. (orig.)

  8. Performance monitoring and analysis of task-based OpenMP.

    Directory of Open Access Journals (Sweden)

    Yi Ding

    Full Text Available OpenMP, a typical shared memory programming paradigm, has been extensively applied in high performance computing community due to the popularity of multicore architectures in recent years. The most significant feature of the OpenMP 3.0 specification is the introduction of the task constructs to express parallelism at a much finer level of detail. This feature, however, has posed new challenges for performance monitoring and analysis. In particular, task creation is separated from its execution, causing the traditional monitoring methods to be ineffective. This paper presents a mechanism to monitor task-based OpenMP programs with interposition and proposes two demonstration graphs for performance analysis as well. The results of two experiments are discussed to evaluate the overhead of monitoring mechanism and to verify the effects of demonstration graphs using the BOTS benchmarks.

  9. Perfmon2: a leap forward in performance monitoring

    International Nuclear Information System (INIS)

    Jarp, S; Jurga, R; Nowak, A

    2008-01-01

    This paper describes the software component, perfmon2, that is about to be added to the Linux kernel as the standard interface to the Performance Monitoring Unit (PMU) on common processors, including x86 (AMD and Intel), Sun SPARC, MIPS, IBM Power and Intel Itanium. It also describes a set of tools for doing performance monitoring in practice and details how the CERN openlab team has participated in the testing and development of these tools

  10. Perfmon2: a leap forward in performance monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Jarp, S; Jurga, R; Nowak, A [CERN, Geneva (Switzerland)], E-mail: Sverre.Jarp@cern.ch

    2008-07-15

    This paper describes the software component, perfmon2, that is about to be added to the Linux kernel as the standard interface to the Performance Monitoring Unit (PMU) on common processors, including x86 (AMD and Intel), Sun SPARC, MIPS, IBM Power and Intel Itanium. It also describes a set of tools for doing performance monitoring in practice and details how the CERN openlab team has participated in the testing and development of these tools.

  11. Perfmon2 a leap forward in performance monitoring

    CERN Document Server

    Jarp, S; Nowak, A

    2008-01-01

    This paper describes the software component, perfmon2, that is about to be added to the Linux kernel as the standard interface to the Performance Monitoring Unit (PMU) on common processors, including x86 (AMD and Intel), Sun SPARC, MIPS, IBM Power and Intel Itanium. It also describes a set of tools for doing performance monitoring in practice and details how the CERN openlab team has participated in the testing and development of these tools.

  12. Perfmon2: a leap forward in performance monitoring

    Science.gov (United States)

    Jarp, S.; Jurga, R.; Nowak, A.

    2008-07-01

    This paper describes the software component, perfmon2, that is about to be added to the Linux kernel as the standard interface to the Performance Monitoring Unit (PMU) on common processors, including x86 (AMD and Intel), Sun SPARC, MIPS, IBM Power and Intel Itanium. It also describes a set of tools for doing performance monitoring in practice and details how the CERN openlab team has participated in the testing and development of these tools.

  13. Alignment performance monitoring for ASML systems

    Science.gov (United States)

    Chung, Woong-Jae; Temchenko, Vlad; Hauck, Tarja; Schmidt, Sebastian

    2006-03-01

    In today's semiconductor industry downscaling of the IC design puts a stringent requirement on pattern overlay control. Tighter overlay requirements lead to exceedingly higher rework rates, meaning additional costs to manufacturing. Better alignment control became a target of engineering efforts to decrease rework rate for high-end technologies. Overlay performance is influenced by known parameters such as "Shift, Scaling, Rotation, etc", and unknown parameters defined as "Process Induced Variation", which are difficult to control by means of a process automation system. In reality, this process-induced variation leads to a strong wafer to wafer, or lot to lot variation, which are not easy to detect in the mass-production environment which uses sampling overlay measurements for only several wafers in a lot. An engineering task of finding and correcting a root cause for Process Induced Variations of overlay performance will be greatly simplified if the unknown parameters could be tracked for each wafer. This paper introduces an alignment performance monitoring method based on analysis of automatically generated "AWE" files for ASML scanner systems. Because "AWE" files include alignment results for each aligned wafer, it is possible to use them for monitoring, controlling and correcting the causes of "process induced" overlay performance without requiring extra measurement time. Since "AWE" files include alignment information for different alignment marks, it is also possible to select and optimize the best alignment recipe for each alignment strategy. Several case studies provided in our paper will demonstrate how AWE file analysis can be used to assist engineer in interpreting pattern alignment data. Since implementing our alignment data monitoring method, we were able to achieve significant improvement of alignment and overlay performance without additional overlay measurement time. We also noticed that the rework rate coming from alignment went down and

  14. Problems and principles of NPP diagnostics on the basis of mode parameter monitoring. Problemy i printsipy diagnostirovaniya YaEhU na osnove kontrolya rezhimnykh parametrov

    Energy Technology Data Exchange (ETDEWEB)

    Znyshev, V V

    1990-01-01

    Ideology of an approach to solving the problem of functional NPP diagnostics according to data on the dynamics of the plant monitored mode parameter dynamics, is presented. Difficulties in solving caused by NPP specific features as a diagnostics object are considered. Practical reasons simplifying the problem are expressed.

  15. Digital Image Correlation for Performance Monitoring

    Science.gov (United States)

    Palaviccini, Miguel; Turner, Dan; Herzberg, Michael

    2016-01-01

    Evaluating the health of a mechanism requires more than just a binary evaluation of whether an operation was completed. It requires analyzing more comprehensive, full-field data. Health monitoring is a process of non-destructively identifying characteristics that indicate the fitness of an engineered component. In order to monitor unit health in a production setting, an automated test system must be created to capture the motion of mechanism parts in a real-time and non-intrusive manner. One way to accomplish this is by using high-speed video and Digital Image Correlation (DIC). In this approach, individual frames of the video are analyzed to track the motion of mechanism components. The derived performance metrics allow for state-of-health monitoring and improved fidelity of mechanism modeling. The results are in-situ state-of-health identification and performance prediction. This paper introduces basic concepts of this test method, and discusses two main themes: the use of laser marking to add fiducial patterns to mechanism components, and new software developed to track objects with complex shapes, even as they move behind obstructions. Finally, the implementation of these tests into an automated tester is discussed.

  16. The diagnostic performance of chronologic age in the assessment of skeletal maturity.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; De Toffol, Laura; Ghiozzi, Bruno; Cozza, Paola

    2006-01-01

    The aim of this study was to analyze the relationship between chronologic age the and individual skeletal maturity as assessed by means of the cervical vertebral maturation (CVM) method during the circumpubertal period. The evaluated sample of 600 subjects consisted of 100 subjects (50 males and 50 females) for each of 6 age groups, from 9 years through 14 years of age. Individual skeletal maturity for all subjects was determined by using the CVM method. The relationship between chronologic age and the most prevalent CVM stage at each age group was evaluated statistically by means of indicators of diagnostic test performance that specify the ability of a diagnostic test to identify a condition. The diagnostic performance of chronologic age for the detection of the onset of the adolescent peak in skeletal maturation was very low both in males and in females. In male subjects, the chronologic age of 9 years +/- 6 months presented with strong diagnostic power for the identification of a pre-pubertal stage in skeletal maturation. In female subjects, the chronologic age of 14 years +/- 6 months corresponded with a strong probability of a postpubertal stage in skeletal maturation. In males, chronologic age can identify a pre-pubertal stage of skeletal development, and in females a post-pubertal stage. In both males and females, chronologic age cannot recognize the onset of the adolescent peak in skeletal maturation.

  17. Methodology for quantitative evalution of diagnostic performance. Project III

    International Nuclear Information System (INIS)

    Metz, C.E.

    1985-01-01

    Receiver Operation Characteristic (ROC) methodology is now widely recognized as the most satisfactory approach to the problem of measuring and specifying the performance of a diagnostic procedure. The primary advantage of ROC analysis over alternative methodologies is that it seperates differences in diagnostic accuracy that are due to actual differences in discrimination capacity from those that are due to decision threshold effects. Our effort during the past year has been devoted to developing digital computer programs for fitting ROC curves to diagnostic data by maximum likelihood estimation and to developing meaningful and valid statistical tests for assessing the significance of apparent differences between measured ROC curves. FORTRAN programs previously written here for ROC curve fitting and statistical testing have been refined to make them easier to use and to allow them to be run in a large variety of computer systems. We have attempted also to develop two new curve-fitting programs: one for conventional ROC data that assumes a different functional form for the ROC curve, and one that can be used for ''free-response'' ROC data. Finally, we have cooperated with other investigators to apply our techniques to analyze ROC data generated in clinical studies, and we have sought to familiarize the medical community with the advantages of ROC methodology. 36 ref

  18. On-line monitoring of main coolant pump seals

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; Glass, S.W.; Sommerfield, G.A.; Harrison, D.

    1984-06-01

    The Babcock and Wilcox Company has developed and implemented a Reactor Coolant Pump Monitoring and Diagnostic System (RCPM and DS). The system has been installed at Toledo Edison Company's Davis-Besse Nuclear Power Station Unit 1. The RCPM and PS continuously monitors a number of indicators of pump performance and notifies the plant operator of out-of-tolerance conditions or pump performance trending toward out-of-tolerance conditions. Pump seal parameters being monitored include pump internal pressures, temperatures, and flow rates. Rotordynamic performanvce and plant operating conditions are also measured with a variety of dynamic sensors. This paper describes the implementation of the system and the results of on-line monitoring of four RC pumps

  19. Improving the diagnostic performance of lung scintigraphy in suspected pulmonary embolic disease

    International Nuclear Information System (INIS)

    Gleeson, F.V.; Turner, S.; Scarsbrook, A.F.

    2006-01-01

    Aim: to determine the effectiveness of a new imaging algorithm in the investigation of suspected pulmonary embolism (PE). Materials and methods: A new imaging algorithm for suspected PE was introduced following the installation of a multisection computed tomography (CT) machine at our institution. Before its installation, patients with suspected PE were evaluated with ventilation/perfusion (V/Q) scintigraphy. Subsequently, patients were triaged according to chest radiography (CR) and respiratory history to either lung scintigraphy or CT pulmonary angiography (CTPA). Patients with a normal CR and no history of lung disease were evaluated using perfusion (Q) scintigraphy [ventilation (V) scintigraphy was no longer performed]. Patients with an abnormal CR, asthma or chronic lung disease were evaluated using CTPA. All V/Q images in a continuous 3-year period before the introduction of the new imaging algorithm and all Q images performed in a 3-year period after its introduction were retrospectively reviewed. Imaging reports were categorized into normal, non-diagnostic (low or intermediate probability) or high probability for PE. Patients in the later group who subsequently underwent CTPA, were also reviewed. Results: After the policy change the percentage of normal scintigrams significantly increased (39 to 60%; p < 0.001). There was a non-significant increase in the percentage of high probability scintigrams (15 to 18%; p = 0.716). Overall the diagnostic yield of lung scintigraphy improved significantly (54 to 78%; p < 0.001). Conclusion: the diagnostic performance of lung scintigraphy can be improved by careful triage of patients to either Q scintigraphy or CTPA based on clinical history and CR findings. Q scintigraphy remains a valuable diagnostic test in the investigation of suspected PE in carefully selected patients

  20. ITER diagnostic system: Vacuum interface

    Energy Technology Data Exchange (ETDEWEB)

    Patel, K.M., E-mail: Kaushal.Patel@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Drevon, J.M. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Encheva, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Kashchuk, Y. [Institution “PROJECT CENTER ITER”, 1, Akademika Kurchatova pl., Moscow (Russian Federation); Maquet, Ph. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France)

    2013-10-15

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10{sup −7} Pa, irrespective of plasma operation, and a leak rate of less than 10{sup −10} Pa m{sup 3} s{sup −1}. In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions

  1. ITER diagnostic system: Vacuum interface

    International Nuclear Information System (INIS)

    Patel, K.M.; Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L.; Drevon, J.M.; Encheva, A.; Kashchuk, Y.; Maquet, Ph.; Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J.

    2013-01-01

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10 −7 Pa, irrespective of plasma operation, and a leak rate of less than 10 −10 Pa m 3 s −1 . In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions will be described

  2. Development trends for diagnostic systems in nuclear power plants

    International Nuclear Information System (INIS)

    Kunze, U.; Pohl, U.

    1998-01-01

    Monitoring systems used in nuclear power plants have made remarkable progress over the past four or five years. Development has followed the trends and changes in philosophy for the purpose of monitoring systems in nuclear power plants: They are no longer expected to fulfill only safety tasks, the plant personnel require information on which to base condition-oriented maintenance. A new generation of monitoring and diagnostic systems has been developed by Siemens recently. This new generation, called Series '95, is PC-based. An overview is given for the KUeS '95 loose parts diagnostic system, the SUeS '95 vibration monitoring system, the FLUeS leak detection system and the SIPLUG valve diagnostics system. The objectives behind the development of these new systems are both safety-related and economic. The new systems improve the reliability and quality of monitoring techniques and incorporate better detection and diagnostic capabilities. Progress has also been made in automation of the systems so as to reduce routine work, give higher sensitivity for the monitoring task and reduce the scope of maintenance. (author)

  3. Diagnostic performance of CT angiography in patients visiting emergency department with overt gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Kim, Ji Hang; Kim, Young Hoon; Lee, Kyoung Ho; Lee, Yoon Jin; Park, Ji Hoon

    2015-01-01

    To investigate the diagnostic performance of computed tomography angiography (CTA) in identifying the cause of bleeding and to determine the clinical features associated with a positive test result of CTA in patients visiting emergency department with overt gastrointestinal (GI) bleeding. We included 111 consecutive patients (61 men and 50 women; mean age: 63.4 years; range: 28-89 years) who visited emergency department with overt GI bleeding. They underwent CTA as a first-line diagnostic modality from July through December 2010. Two radiologists retrospectively reviewed the CTA images and determined the presence of any definite or potential bleeding focus by consensus. An independent assessor determined the cause of bleeding based on other diagnostic studies and/or clinical follow-up. The diagnostic performance of CTA and clinical characteristics associated with positive CTA results were analyzed. To identify a definite or potential bleeding focus, the diagnostic yield of CTA was 61.3% (68 of 111). The overall sensitivity, specificity, positive predictive value (PPV), and negative predictive value were 84.8% (67 of 79), 96.9% (31 of 32), 98.5% (67 of 68), and 72.1% (31 of 43), respectively. Positive CTA results were associated with the presence of massive bleeding (p = 0.001, odds ratio: 11.506). Computed tomography angiography as a first-line diagnostic modality in patients presenting with overt GI bleeding showed a fairly high accuracy. It could identify definite or potential bleeding focus with a moderate diagnostic yield and a high PPV. CTA is particularly useful in patients with massive bleeding.

  4. Diagnosing psychogenic nonepileptic seizures: Video-EEG monitoring, suggestive seizure induction and diagnostic certainty.

    Science.gov (United States)

    Popkirov, Stoyan; Jungilligens, Johannes; Grönheit, Wenke; Wellmer, Jörg

    2017-08-01

    Psychogenic nonepileptic seizures (PNES) can remain undiagnosed for many years, leading to unnecessary medication and delayed treatment. A recent report by the International League Against Epilepsy Nonepileptic Seizures Task Force recommends a staged approach to the diagnosis of PNES (LaFrance, et al., 2013). We aimed to investigate its practical utility, and to apply the proposed classification to evaluate the role of long-term video-EEG monitoring (VEEG) and suggestive seizure induction (SSI) in PNES workup. Using electronic medical records, 122 inpatients (mean age 36.0±12.9years; 68% women) who received the diagnosis of PNES at our epilepsy center during a 4.3-year time period were included. There was an 82.8% agreement between diagnostic certainty documented at discharge and that assigned retroactively using the Task Force recommendations. In a minority of cases, having used the Task Force criteria could have encouraged the clinicians to give more certain diagnoses, exemplifying the Task Force report's utility. Both VEEG and SSI were effective at supporting high level diagnostic certainty. Interestingly, about one in four patients (26.2%) had a non-diagnostic ("negative") VEEG but a positive SSI. On average, this subgroup did not have significantly shorter mean VEEG recording times than VEEG-positive patients. However, VEEG-negative/SSI-positive patients had a significantly lower habitual seizure frequency than their counterparts. This finding emphasizes the utility of SSI in ascertaining the diagnosis of PNES in patients who do not have a spontaneous habitual event during VEEG due to, for example, low seizure frequency. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Computer-aided performance monitoring program at Diablo Canyon

    International Nuclear Information System (INIS)

    Nelson, T.; Glynn, R. III; Kessler, T.C.

    1992-01-01

    This paper describes the thermal performance monitoring program at Pacific Gas ampersand Electric Company's (PG ampersand E's) Diablo Canyon Nuclear Power Plant. The plant performance monitoring program at Diablo Canyon uses the THERMAC performance monitoring and analysis computer software provided by Expert-EASE Systems. THERMAC is used to collect performance data from the plant process computers, condition that data to adjust for measurement errors and missing data points, evaluate cycle and component-level performance, archive the data for trend analysis and generate performance reports. The current status of the program is that, after a fair amount of open-quotes tuningclose quotes of the basic open-quotes thermal kitclose quotes models provided with the initial THERMAC installation, we have successfully baselined both units to cycle isolation test data from previous reload cycles. Over the course of the past few months, we have accumulated enough data to generate meaningful performance trends and, as a result, have been able to use THERMAC to track a condenser fouling problem that was costing enough megawatts to attract corporate-level attention. Trends from THERMAC clearly related the megawatt loss to a steadily degrading condenser cleanliness factor and verified the subsequent gain in megawatts after the condenser was cleaned. In the future, we expect to rebaseline THERMAC to a beginning of cycle (BOC) data set and to use the program to help track feedwater nozzle fouling

  6. Peripheral occlusive vascular disease: Diagnostic performance of MRA and DSA

    International Nuclear Information System (INIS)

    Krug, B.; Kugel, H.; Harnischmacher, U.; Heindel, W.; Altenburg, A.; Fischbach, R.; Schmidt, R.

    1995-01-01

    In 59 patients with arterial flow disturbances 2-D inflow sequence of the abdominal and lower leg arteries were prospectively obtained on a 1.5 T MR-imager and were compared with additional DSA examinations. Supplementary Phase Contraste RSE ('Rapid Sequential Excitation') sequences were carried out in 29 patients. MRA and DSA angiograms were evaluated in random order by 4 readers using a questionnaire. The assessment of image quality were evaluated by variance analysis. Diagnostic performance of MRA and DSA was assessed by comparison of the readers' diagnostic assessments with reference diagnoses established by a radiologist and a vascular surgeon with full knowledge of all data concerning a patient. Image quality of inflow MRA was considered inferior to i.a. DSA (p [de

  7. Advanced Monitoring to Improve Combustion Turbine/Combined Cycle Reliability, Availability & Maintainability

    Energy Technology Data Exchange (ETDEWEB)

    Leonard Angello

    2005-09-30

    Power generators are concerned with the maintenance costs associated with the advanced turbines that they are purchasing. Since these machines do not have fully established Operation and Maintenance (O&M) track records, power generators face financial risk due to uncertain future maintenance costs. This risk is of particular concern, as the electricity industry transitions to a competitive business environment in which unexpected O&M costs cannot be passed through to consumers. These concerns have accelerated the need for intelligent software-based diagnostic systems that can monitor the health of a combustion turbine in real time and provide valuable information on the machine's performance to its owner/operators. EPRI, Impact Technologies, Boyce Engineering, and Progress Energy have teamed to develop a suite of intelligent software tools integrated with a diagnostic monitoring platform that, in real time, interpret data to assess the 'total health' of combustion turbines. The 'Combustion Turbine Health Management System' (CTHMS) will consist of a series of 'Dynamic Link Library' (DLL) programs residing on a diagnostic monitoring platform that accepts turbine health data from existing monitoring instrumentation. CTHMS interprets sensor and instrument outputs, correlates them to a machine's condition, provide interpretative analyses, project servicing intervals, and estimate remaining component life. In addition, the CTHMS enables real-time anomaly detection and diagnostics of performance and mechanical faults, enabling power producers to more accurately predict critical component remaining useful life and turbine degradation.

  8. Automatic vibration monitoring system for the diagnostic inspection of the WWER-440 type nuclear power plants

    International Nuclear Information System (INIS)

    Hollo, E.; Siklossy, P.; Toth, Zs.

    1982-01-01

    In the Hungarian Research Institute for Electric Power Industry (VEIKI) an automatic vibration monitoring system for diagnostics and inspection of nuclear power plants of type WWER-440 was developed. The paper summarizes the results of this work and investigates the use of mechanical vibrations and oscillations induced by flow for fault diagnosis. The design of the hardware system, the present software possibilities, the laboratory experiments and the guidelines for future software developments are also described in detail. (A.L.)

  9. Data acquisition, monitoring and diagnostic system for predictive control and protection of rotating components of IEAR-1 reactor by vibration analysis

    International Nuclear Information System (INIS)

    Serra, Reynaldo Cavalcanti; Tecco, Dorival Goncalves

    1996-01-01

    This work presents the vibration and temperature data acquisition, monitoring and diagnostic systems, recently installed in the primary circuit, secondary circuit and emergency generator of the IEA-R1 reactor at IPEN during the course of the first power elevation tests to 5MW. It incorporates a series of routines for equipment configuration, interactive automatic monitoring , data processing and documentation/storage without the exposure of operators in the radiological protection areas. (author)

  10. Fast Flux Test Facility performance monitoring management information

    International Nuclear Information System (INIS)

    Newland, D.J.

    1987-11-01

    The purpose of this report is to provide performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ''overall'' and ''other''. The ''overall'' performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance

  11. Overcoming regulatory challenges in the development of companion diagnostics for monitoring and safety.

    Science.gov (United States)

    Shimazawa, Rumiko; Ikeda, Masayuki

    2016-03-01

    Concurrent development and co-approval of a companion diagnostic (CDx) with a corresponding drug is ideal, but often unfeasible. Because of limited exposure to a drug in clinical trials, crucial information on safety is sometimes revealed only after approval. Therefore, a CDx for monitoring/safety is often developed after approval of a corresponding drug. However, regulatory guidance is insufficient if contemporaneous development is not possible, thereby leaving plenty of opportunities for improvement with respect to pharmacovigilance and retrospective validation of the CDx. Furthermore, global harmonization of guidance on how to incorporate new scientific information from retrospective analyses of biomarkers should lead to the establishment of more evidence for the development of CDx for approved drugs.

  12. Impacts of dairy diagnostic teams on herd performance.

    Science.gov (United States)

    Weinand, D; Conlin, B J

    2003-05-01

    This study evaluated impacts of educational diagnostic teams of consultants used to transfer technology to dairy farms. Herd management performance changes were measured by comparing Dairy Herd Improvement data from 38 project farms to data from herds that were geographical contemporaries. The value of focused goals for effecting change was also assessed. Interviews provided producers' perception of project outcomes and insight on organization and conduct of dairy diagnostic teams. Changes observed in project herds were small compared with controls with tendencies for increased herd size and improved milk production per cow. Focused goals had greater impacts on increasing herd size, milk per cow, first lactation peak milk, reducing age at first calving, and percentages of cows with subclinical mastitis. Time, money, facility limitations, labor, and alternative priorities were the most cited constraints to implementing changes. Satisfaction scores of producers were significantly related to the degree that team recommendations were followed. Improved attitudes, quality of life, and financial well-being were benefits listed by a majority of producers from participation in the project. If similar projects were to be offered, 83% said they would participate again, and 69% indicated they would pay at least some of the costs. Project farms served as demonstration farms for 1930 other producers in their respective locales, resulting in a multiplier effect of original advice given by consultant teams. Suggestions by farmer participants for improvements in dairy diagnostic teams included needs for at least some unbiased team members, more frequent meetings, more follow-up on recommendations, and consistency of recommendations with family goals.

  13. Diagnostic Utility of the Social Skills Improvement System Performance Screening Guide

    Science.gov (United States)

    Krach, S. Kathleen; McCreery, Michael P.; Wang, Ye; Mohammadiamin, Houra; Cirks, Christen K.

    2017-01-01

    Researchers investigated the diagnostic utility of the Social Skills Improvement System: Performance Screening Guide (SSIS-PSG). Correlational, regression, receiver operating characteristic (ROC), and conditional probability analyses were run to compare ratings on the SSIS-PSG subscales of Prosocial Behavior, Reading Skills, and Math Skills, to…

  14. The Advanced Monitoring Systems Initiative--Performance Monitoring for DOE Environmental Remediation and Contaminant Containment

    Science.gov (United States)

    Haas, W. J.; Venedam, R. J.; Lohrstorfer, C. F.; Weeks, S. J.

    2005-05-01

    The Advanced Monitoring System Initiative (AMSI) is a new approach to accelerate the development and application of advanced sensors and monitoring systems in support of Department of Energy needs in monitoring the performance of environmental remediation and contaminant containment activities. The Nevada Site Office of the National Nuclear Security Administration (NNSA) and Bechtel Nevada manage AMSI, with funding provided by the DOE Office of Environmental Management (DOE EM). AMSI has easy access to unique facilities and capabilities available at the Nevada Test Site (NTS), including the Hazardous Materials (HazMat) Spill Center, a one-of-a-kind facility built and permitted for releases of hazardous materials for training purposes, field-test detection, plume dispersion experimentation, and equipment and materials testing under controlled conditions. AMSI also has easy access to the facilities and considerable capabilities of the DOE and NNSA National Laboratories, the Special Technologies Laboratory, Remote Sensing Laboratory, Desert Research Institute, and Nevada Universities. AMSI provides rapid prototyping, systems integration, and field-testing, including assistance during initial site deployment. The emphasis is on application. Important features of the AMSI approach are: (1) customer investment, involvement and commitment to use - including definition of needs, desired mode of operation, and performance requirements; and (2) employment of a complete systems engineering approach, which allows the developer to focus maximum attention on the essential new sensing element or elements while AMSI assumes principal responsibility for infrastructure support elements such as power, packaging, and general data acquisition, control, communication, visualization and analysis software for support of decisions. This presentation describes: (1) the needs for sensors and performance monitoring for environmental systems as seen by the DOE Long Term Stewardship Science and

  15. System and Method for Monitoring Piezoelectric Material Performance

    Science.gov (United States)

    Moses, Robert W. (Inventor); Fox, Christopher L. (Inventor); Fox, Melanie L. (Inventor); Chattin, Richard L. (Inventor); Shams, Qamar A. (Inventor); Fox, Robert L. (Inventor)

    2007-01-01

    A system and method are provided for monitoring performance capacity of a piezoelectric material that may form part of an actuator or sensor device. A switch is used to selectively electrically couple an inductor to the piezoelectric material to form an inductor-capacitor circuit. Resonance is induced in the inductor-capacitor circuit when the switch is operated to create the circuit. The resonance of the inductor-capacitor circuit is monitored with the frequency of the resonance being indicative of performance capacity of the device's piezoelectric material.

  16. Diagnostic accuracy of mammography readers and their memory performance have no correlation with each other

    International Nuclear Information System (INIS)

    Kok, P.; Cawson, J.N.; Mercuri, V.; Pitman, A.G.; Gledhill, S.; Shnier, D.; Taft, R.; Zentner, L.

    2010-01-01

    Full text: The study aims to determine if any association exists between visual memory performance and diagnostic accuracy performance in a group of radiologist mammogram readers. Materials and Methods: One hundred proven mammograms (23 with cancers) were grouped into 5 sets of 20 cases, with sets being of equal difficulty. Pairs of sets were presented in 5 reads (40 cases per read, order random) to a panel of 8 radiologist readers (either present or past screening readers, with experience range from 20 years). The readers were asked to either 'clear' or 'call back' cases depending on need for further workup, and at post-baseline reads to indicate whether each case was 'new' or 'old' (i .e. remembered from prior read). Two sets were presented only at baseline (40 cases per reader), and were used to calculate the reader's false recollection rate. Three sets were repeated post-baseline once or twice (100 cases per reader). Reading conditions were standardised. Results: Memory performance differed markedly between readers. The number of correctly remembered cases (of 100 'old' cases) had a median of 10.5 and range of 0-58. The observed number of false recollections (of 40 'totally new' cases) had a median of 2 and range of 0-17. Diagnostic performance measures were mean (range): sensitivity 0.68 (0.54-0.81); specificity 0.82 (0.74-0.91); positive predictive value (PPV) 0.55 (0.500.65); negative predictive value (NPV) 0.89 (0.86-0.93) and accuracy 0.78 (0.76-0.83). Confidence intervals (CIs; 95%) for each reader overlapped for all the diagnostic parameters, indicating a lack of statistically significant difference between the readers at the 5% level. The most sensitive and the most specific reader showed a trend away from each other on sensitivity, specificity, NPV and PPV; their accuracies were 0.76 and 0.82, respectively, and their accuracy 95% CIs overlapped considerably. Correlation analysis by reader showed no association between observed memory performance and

  17. Materiomics for Oral Disease Diagnostics and Personal Health Monitoring: Designer Biomaterials for the Next Generation Biomarkers

    Science.gov (United States)

    Zhang, Wenjun; Wang, Ming L.; Khalili, Sammy

    2016-01-01

    Abstract We live in exciting times for a new generation of biomarkers being enabled by advances in the design and use of biomaterials for medical and clinical applications, from nano- to macro-materials, and protein to tissue. Key challenges arise, however, due to both scientific complexity and compatibility of the interface of biology and engineered materials. The linking of mechanisms across scales by using a materials science approach to provide structure–process–property relations characterizes the emerging field of ‘materiomics,’ which offers enormous promise to provide the hitherto missing tools for biomaterial development for clinical diagnostics and the next generation biomarker applications towards personal health monitoring. Put in other words, the emerging field of materiomics represents an essentially systematic approach to the investigation of biological material systems, integrating natural functions and processes with traditional materials science perspectives. Here we outline how materiomics provides a game-changing technology platform for disruptive innovation in biomaterial science to enable the design of tailored and functional biomaterials—particularly, the design and screening of DNA aptamers for targeting biomarkers related to oral diseases and oral health monitoring. Rigorous and complementary computational modeling and experimental techniques will provide an efficient means to develop new clinical technologies in silico, greatly accelerating the translation of materiomics-driven oral health diagnostics from concept to practice in the clinic. PMID:26760957

  18. Point-of-care coagulation monitoring: first clinical experience using a paper-based lateral flow diagnostic device.

    Science.gov (United States)

    Hegener, Michael A; Li, Hua; Han, Daewoo; Steckl, Andrew J; Pauletti, Giovanni M

    2017-09-01

    Vitamin K antagonists such as warfarin are the most widely used class of oral anticoagulants. Due to a narrow therapeutic window, patients on warfarin require regular monitoring. Self-testing using point-of-care (POC) diagnostic devices is available, but cost makes this monitoring method beyond reach for many. The main objective of this research was to assess the clinical utility of a low-cost, paper-based lateral flow POC diagnostic device developed for anticoagulation monitoring without the need for a separate electronic reader. Custom-fabricated lateral flow assay (LFA) test strips comprised of a glass fiber sample pad, a nitrocellulose analytical membrane, a cellulose wicking pad, and a plastic backing card were assembled in a plastic cassette. Healthy volunteers and patients on warfarin therapy were recruited for this prospective study. For each participant, a whole blood sample was collected via fingerstick to determine: (1) international normalized ratio (INR) using the CoaguChek® XS coagulometer, (2) hematocrit by centrifugation, and (3) red blood cell (RBC) travel distance on the experimental LFA device after 240 s using digital image analysis. RBC travel distance measured on the LFA device using blood samples obtained from warfarin patients positively correlated with increasing INR value and the LFA device had the capability to statistically distinguish between healthy volunteer INR values and those for patients groups with INR ≥ 2.6. From these data, it is predicted that this low-cost, paper-based LFA device can have clinical utility for identifying anticoagulated patients taking vitamin K antagonists who are outside of the desired therapeutic efficacy window.

  19. Transfer from point-of-care Ultrasonography training to diagnostic performance on patients--a randomized controlled trial

    DEFF Research Database (Denmark)

    Todsen, Tobias; Jensen, Morten Lind; Tolsgaard, Martin Grønnebæk

    2016-01-01

    BACKGROUND: Clinicians are increasingly using point-of-care ultrasonography for bedside examinations of patients. However, proper training is needed in this technique, and it is unknown whether the skills learned from focused Ultrasonography courses are being transferred to diagnostic performance...... test and binary logistic regression, respectively. RESULTS: There was a significant difference in the performance score between the intervention group (27.4%) and the control group (18.0%, P = .004) and the diagnostic accuracy between the intervention group (65%) and the control group (39%, P = .014......). CONCLUSIONS: Clinicians could successfully transfer learning from an Ultrasonography course to improve diagnostic performance on patients. However, our results also indicate a need for more training when new technologies such as point-of-care ultrasonography are introduced....

  20. Experimental Adaptive Digital Performance Monitoring for Optical DP-QPSK Coherent Receiver

    DEFF Research Database (Denmark)

    Borkowski, Robert; Zhang, Xu; Zibar, Darko

    2011-01-01

    We report on a successful experimental demonstration of a digital optical performance monitoring (OPM) yielding satisfactory estimation accuracy along with adaptive impairment equalization. No observable penalty is measured when equalizer is driven by monitoring module.......We report on a successful experimental demonstration of a digital optical performance monitoring (OPM) yielding satisfactory estimation accuracy along with adaptive impairment equalization. No observable penalty is measured when equalizer is driven by monitoring module....

  1. Radio frequency diagnostics on board of Cubesat as a tool for planetary Space Weather monitoring

    Science.gov (United States)

    Rothkaehl, H.; Morawski, M.; Szewczyk, T.

    2014-04-01

    CubeSat pico-satellite standard was developed recently to allow easy access to space for projects with limited funds. Due to relatively cheap yet professional development process, CubeSats have also great educational impact. This allows the students to learn about all crucial aspects of space engineering and project management. Since all the basic steps for developing CubeSat are similar to those performed on bigger satellites (i.e. designing, testing, operating in space), this gives possibility to develop all the necessary skills and experience for future work at space industries. Space Research Center, together with its collaborators from University of Warmia and Mazury in Olsztyn and others, would like to design and build double unit CubeSat as an opportunity to perform scientific experiments in space together with technological demonstrators of subsystems. In order to monitor the Earth's and planetary space environment and obtain a much more complete picture of magnetosphere and ionosphere coupling and particularly waves-particle interaction in this system than those available hitherto new mission of clustered Cubesat mission can be propose. Moreover to enhance our understanding of the rich plasma physical processes that drive the Solar Terrestrial space environment, we need to increase our ability to perform multi-point measurements by means of different sensors. Therefore, new technologies radio frequency radio analyser RFA instrument will gave the possibility for diagnostics 3D electric field component (spectra and wave forms) with extremely high time resolution. Additional technological challenges regarding size, computational power and energy constraints are imposed by the design of CubeSat.

  2. Nuclear power plant diagnostics

    International Nuclear Information System (INIS)

    Hollo, E.; Siklossy, P.

    1982-01-01

    The cooling circuit vibration diagnostic system of the Block 1 of the Paks nuclear power station is described. The automatic online vibration monitoring system consisting presently of 42 acceleration sensors and 9 pressure fluctuation sensors, which could be extended, performs both global and local inspection of the primary cooling circuit and its components. The offline data processing system evaluates the data for failure mode analysis. The software under development will be appropriate for partial preliminary identification of failure reasons during their initial phases. The installation experiences and the preliminary results during the hot operational testing of Block 1 are presented. (Sz.J.)

  3. Diagnostic performance of traditional hepatobiliary biomarkers of drug-induced liver injury in the rat.

    Science.gov (United States)

    Ennulat, Daniela; Magid-Slav, Michal; Rehm, Sabine; Tatsuoka, Kay S

    2010-08-01

    Nonclinical studies provide the opportunity to anchor biochemical with morphologic findings; however, liver injury is often complex and heterogeneous, confounding the ability to relate biochemical changes with specific patterns of injury. The aim of the current study was to compare diagnostic performance of hepatobiliary markers for specific manifestations of drug-induced liver injury in rat using data collected in a recent hepatic toxicogenomics initiative in which rats (n = 3205) were given 182 different treatments for 4 or 14 days. Diagnostic accuracy of alanine aminotransferase (ALT), aspartate aminotransferase (AST), total bilirubin (Tbili), serum bile acids (SBA), alkaline phosphatase (ALP), gamma glutamyl transferase (GGT), total cholesterol (Chol), and triglycerides (Trig) was evaluated for specific types of liver histopathology by Receiver Operating Characteristic (ROC) analysis. To assess the relationship between biochemical and morphologic changes in the absence of hepatocellular necrosis, a second ROC analysis was performed on a subset of rats (n = 2504) given treatments (n = 152) that did not cause hepatocellular necrosis. In the initial analysis, ALT, AST, Tbili, and SBA had the greatest diagnostic utility for manifestations of hepatocellular necrosis and biliary injury, with comparable magnitude of area under the ROC curve and serum hepatobiliary marker changes for both. In the absence of hepatocellular necrosis, ALT increases were observed with biochemical or morphologic evidence of cholestasis. In both analyses, diagnostic utility of ALP and GGT for biliary injury was limited; however, ALP had modest diagnostic value for peroxisome proliferation, and ALT, AST, and total Chol had moderate diagnostic utility for phospholipidosis. None of the eight markers evaluated had diagnostic value for manifestations of hypertrophy, cytoplasmic rarefaction, inflammation, or lipidosis.

  4. Performance Monitoring and Evaluation in Botswana’s Public Service: Achievements and Challenges

    Directory of Open Access Journals (Sweden)

    Dorothy Mpabanga

    2016-03-01

    Full Text Available The paper aims to explore the implementation of performance monitoring and evaluation tools used in Botswana’s public service. The paper also identifies achievements and challenges of implementing performance monitoring and evaluation system and suggests ways for improvement. This paper uses secondary data sources. The paper reveals lack of performance monitoring and evaluation skills, poor supervision, poor conditions of service and a poor work ethic as some of the factors contributing to ineffective use of performance monitoring and evaluation tools in the service. Leadership commitment and support, benchmarking reforms, training and education, developed administrative and governance structures as well as well-defined public policy and program formulation and implementation processes are some of the success factors to enhanced performance management and evaluation systems in Botswana. The paper argues for adoption of a developmental-led model in order to enhance existing performance monitoring and evaluation system that would improve implementation of government policies and programs. Botswana has been striving to excel in service delivery through performance monitoring and evaluation oriented reforms.

  5. Smartphone-Based Fluorescent Diagnostic System for Highly Pathogenic H5N1 Viruses

    OpenAIRE

    Yeo, Seon-Ju; Choi, Kyunghan; Cuc, Bui Thi; Hong, Nguyen Ngoc; Bao, Duong Tuan; Ngoc, Nguyen Minh; Le, Mai Quynh; Hang, Nguyen Le Khanh; Thach, Nguyen Co; Mallik, Shyam Kumar; Kim, Hak Sung; Chong, Chom-Kyu; Choi, Hak Soo; Sung, Haan Woo; Yu, Kyoungsik

    2016-01-01

    Field diagnostic tools for avian influenza (AI) are indispensable for the prevention and controlled management of highly pathogenic AI-related diseases. More accurate, faster and networked on-site monitoring is demanded to detect such AI viruses with high sensitivity as well as to maintain up-to-date information about their geographical transmission. In this work, we assessed the clinical and field-level performance of a smartphone-based fluorescent diagnostic device with an efficient reflect...

  6. Improved data acquisition methods for uninterrupted signal monitoring and ultra-fast plasma diagnostics in LHD

    International Nuclear Information System (INIS)

    Nakanishi, Hideya; Imazu, Setsuo; Ohsuna, Masaki

    2012-01-01

    To deal with endless data streams acquired in LHD steady-state experiments, the LHD data acquisition system was designed with a simple concept that divides a long pulse into a consecutive series of 10-s “subshots”. Latest digitizers applying high-speed PCI-Express technology, however, output nonstop gigabyte per second data streams whose subshot intervals would be extremely long if 10-s rule was applied. These digitizers need shorter subshot intervals, less than 10-s long. In contrast, steady-state fusion plants need uninterrupted monitoring of the environment and device soundness. They adopt longer subshot lengths of either 10 min or 1 day. To cope with both uninterrupted monitoring and ultra-fast diagnostics, the ability to vary the subshot length according to the type of operation is required. In this study, a design modification that enables variable subshot lengths was implemented and its practical effectiveness in LHD was verified. (author)

  7. Optical Performance Monitoring and Signal Optimization in Optical Networks

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2006-01-01

    The thesis studies performance monitoring for the next generation optical networks. The focus is on all-optical networks with bit-rates of 10 Gb/s or above. Next generation all-optical networks offer large challenges as the optical transmitted distance increases and the occurrence of electrical-optical......-electrical regeneration points decreases. This thesis evaluates the impact of signal degrading effects that are becoming of increasing concern in all-optical high-speed networks due to all-optical switching and higher bit-rates. Especially group-velocity-dispersion (GVD) and a number of nonlinear effects will require...... enhanced attention to avoid signal degradations. The requirements for optical performance monitoring features are discussed, and the thesis evaluates the advantages and necessity of increasing the level of performance monitoring parameters in the physical layer. In particular, methods for optical...

  8. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    Science.gov (United States)

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory

  9. TFTR diagnostic vacuum controller

    International Nuclear Information System (INIS)

    Olsen, D.; Persons, R.

    1981-01-01

    The TFTR diagnostic vacuum controller (DVC) provides in conjunction with the Central Instrumentation Control and Data Acquisition System (CICADA), control and monitoring for the pumps, valves and gauges associated with each individual diagnostic vacuum system. There will be approximately 50 systems on TFTR. Two standard versions of the controller (A and B) wil be provided in order to meet the requirements of two diagnostic manifold arrangements. All pump and valve sequencing, as well as protection features, will be implemented by the controller

  10. Computer modeling and design of diagnostic workstations and radiology reading rooms

    Science.gov (United States)

    Ratib, Osman M.; Amato, Carlos L.; Balbona, Joseph A.; Boots, Kevin; Valentino, Daniel J.

    2000-05-01

    We used 3D modeling techniques to design and evaluate the ergonomics of diagnostic workstation and radiology reading room in the planning phase of building a new hospital at UCLA. Given serious space limitations, the challenge was to provide more optimal working environment for radiologists in a crowded and busy environment. A particular attention was given to flexibility, lighting condition and noise reduction in rooms shared by multiple users performing diagnostic tasks as well as regular clinical conferences. Re-engineering workspace ergonomics rely on the integration of new technologies, custom designed cabinets, indirect lighting, sound-absorbent partitioning and geometric arrangement of workstations to allow better privacy while optimizing space occupation. Innovations included adjustable flat monitors, integration of videoconferencing and voice recognition, control monitor and retractable keyboard for optimal space utilization. An overhead compartment protecting the monitors from ambient light is also used as accessory lightbox and rear-view projection screen for conferences.

  11. Static dosimetry space image in which urology diagnostics are performed

    International Nuclear Information System (INIS)

    Banduka, M.S.; Vasic, D.D.

    2002-01-01

    Background. The effects of the dispersed radiation described theoretically imply complex picture of interaction of the photon beam with the patient's body, as well as its dispersion on other structures. Basic theoretical laws of this phenomenon are highlighted, thus giving the opportunity to model the effect in total. Material and methods. The measurements of the absorbed dose in the air give isodose curves that show distribution of the radiation dose. For the urological procedures standard urological diagnostic methods were being used. Results. Through a large series of measuring, we got the distribution of the radiation dose in space, where urology diagnostics is being made using the X-ray. The parameters determining this picture are the most frequent ones in the total number of 20 random cases taken in General Hospital in Doboj, Bosnia and Herzegovina. Conclusions. Static dosimetric picture of the space (radiation zone) in the general sense is useful before all for organisation of the diagnostic procedures utilising ionised radiation. Obtained in any way, this picture enables an insight into the three-dimensional distribution of the dosage on the basis of which it is possible to correct the organisation of the diagnostics being performed under these conditions. The values of the radiation dosage show it is necessary to use the protecting means prescribed by law. For more frequent exposure, it would be useful to make a dynamic dosimetric picture for professional exposure and assessment of the radiation risk of these persons. (author)

  12. Performance test of personal RF monitor for area monitoring at magnetic confinement fusion facility

    International Nuclear Information System (INIS)

    Tanaka, M.; Uda, T.; Wang, J.; Fujiwara, O.

    2012-01-01

    For safety management at a magnetic confinement fusion-test facility, protection from not only ionising radiation, but also non-ionising radiation such as the leakage of static magnetic and electromagnetic fields is an important issue. Accordingly, the use of a commercially available personal RF monitor for multipoint area monitoring is proposed. In this study, the performance of both fast- and slow-type personal RF monitors was investigated by using a transverse electromagnetic cell system. The range of target frequencies was between 10 and 300 MHz, corresponding to the ion cyclotron range of frequency in a fusion device. The personal RF monitor was found to have good linearity, frequency dependence and isotropic response. However, the time constant for the electric field sensor of the slow-type monitor was much longer than that for the fast-type monitor. Considering the time-varying field at the facility, it is found that the fast-type monitor is suitable for multipoint monitoring at magnetic confinement fusion test facilities. (authors)

  13. Overview of ion source characterization diagnostics in INTF

    Science.gov (United States)

    Bandyopadhyay, M.; Sudhir, Dass; Bhuyan, M.; Soni, J.; Tyagi, H.; Joshi, J.; Yadav, A.; Rotti, C.; Parmar, Deepak; Patel, H.; Pillai, S.; Chakraborty, A.

    2016-02-01

    INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

  14. Standard guide for in-plant performance evaluation of automatic pedestrian SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This guide is affiliated with Guide C1112 on special nuclear material (SNM) monitors, Guide C1169 on laboratory performance evaluation, and Guide C1189 on calibrating pedestrian SNM monitors. This guide to in-plant performance evaluation is a comparatively rapid way to verify whether a pedestrian SNM monitor performs as expected for detecting SNM or SNM-like test sources. 1.1.1 In-plant performance evaluation should not be confused with the simple daily functional test recommended in Guide C1112. In-plant performance evaluation takes place less often than daily tests, usually at intervals ranging from weekly to once every three months. In-plant evaluations are also more extensive than daily tests and may examine both a monitor's nuisance alarm record and its detection sensitivity for a particular SNM or alternative test source. 1.1.2 In-plant performance evaluation also should not be confused with laboratory performance evaluation. In-plant evaluation is comparatively rapid, takes place in the monitor...

  15. Monitoring SLAC High Performance UNIX Computing Systems

    International Nuclear Information System (INIS)

    Lettsome, Annette K.

    2005-01-01

    Knowledge of the effectiveness and efficiency of computers is important when working with high performance systems. The monitoring of such systems is advantageous in order to foresee possible misfortunes or system failures. Ganglia is a software system designed for high performance computing systems to retrieve specific monitoring information. An alternative storage facility for Ganglia's collected data is needed since its default storage system, the round-robin database (RRD), struggles with data integrity. The creation of a script-driven MySQL database solves this dilemma. This paper describes the process took in the creation and implementation of the MySQL database for use by Ganglia. Comparisons between data storage by both databases are made using gnuplot and Ganglia's real-time graphical user interface

  16. Diagnostic system for primary circuits of pressurized-water reactors

    International Nuclear Information System (INIS)

    Liska, J.; Majer, J.

    1983-01-01

    The diagnostic system monitors the reactor, the main circulating pipe, the main circulating pump, the main shut-off valve, the steam generator and the pressurizer. Diagnostic signals are obtained from the sensors designed for operation measurements and from sensors for special diagnostic purposes. The following operations are carried out: detection of dangerous dynamic stress of components, detection of damage to functional surfaces of components, detection of occurrence and propagation of defects in component materials, detection of loose particles and foreign bodies, detection of coolant leakage, detection of coolant boiling in the core and detection of impermissible non-homogeneities of fields of physical quantities in the core. The diagnostic system comprises: monitoring, classification of properly investigated effects, periodical tracing and long-term tracing. The operational diagnostics system developed by the SKODA Concern consists of a vibration monitoring system, a spectral analysis system and a central evaluation system. (M.D.)

  17. Low cut-off values increase diagnostic performance of protein S assays

    NARCIS (Netherlands)

    Mulder, Rene; ten Kate, Min Ki; Kluin-Nelemans, Hanneke C.; Mulder, Andre B.

    Conflicting data have been reported on the accuracy of protein S (PS) assays for detection of hereditary PS deficiency. In this study we assessed the diagnostic performance of two total PS antigen assays, four free PS assays and three PS activity assays in a group of 28 heterozygous carriers of

  18. PingER: Internet performance monitoring -- How do collisions make better physics

    International Nuclear Information System (INIS)

    Matthews, W.

    2000-01-01

    Internet connectivity is critical infrastructure for modern high energy nuclear and particle physics experiments at laboratories around the world. Achieving the ambitious computing goals is dependent on reliable and fast connections between collaborators in geographically separate regions. The ambitious computing goals of experiments such as BaBar, RHIC and the LHC place internet connectivity in a highly critical position. More over the ability to monitor performance and identify weak points for upgrades has become pivotal to recruiting collaborators not only overseas from the location of the experiment but in locations previously considered remote. The methodology of the Internet End-to-End Performance Monitoring (IEPM) project and long-term trends in regional and trans-oceanic performance measured by the PingER tools has previously been described. The project has grown significantly and now 593 nodes at 424 sites in 72 countries are monitored by 28 monitoring sites in 15 countries. A total of 2,138 end-to-end pairs are monitored, making PingER probably the largest performance monitoring project in the world. Recently particular effort has been made to extend the monitoring of locations in East Europe and the former USSR and to Central and South America and the Middle East, reflecting the increasing reach of high energy nuclear and particle physics research

  19. Optical design of the TMX Thomson Scattering Diagnostic

    International Nuclear Information System (INIS)

    Frank, A.M.

    1979-01-01

    The Thomson Scattering Diagnostic on TMX was built to measure the electron temperature in the plug. The design was based on the 2XII system built by Tom Simonen. Substantial improvements were realized over the original design, these include: (1) improved sensitivity, (2) simultaneous multiple position sampling, (3) multiple pulse capability, (4) achromatic imaging, (5) vacuum alignment capability, (6) high reliability, and (7) built in calibration and performance monitoring

  20. Commissioning of an electro-optic electron bunch length monitor at FLASH

    International Nuclear Information System (INIS)

    Breunlin, Jonas

    2011-03-01

    The demands on the electron beam qualities for free-electron lasers (FEL) are challenging in terms of high peak currents. At FLASH, the high-gain FEL in Hamburg, longitudinal bunch compression is performed to achieve the requested high charge densities in short bunches. The precise control of the bunch compression process requires advanced diagnostics on the longitudinal bunch profile. The bunch length monitor presented in this thesis is based on a non-destructive detection using the electro-optic effect. The focus is on a compact and reliable system for permanent bunch diagnostics. The monitor provides single-shot measurements of the longitudinal bunch profiles with lengths of a few picoseconds by spectrally encoding their charge distribution. First measurements for characterization purpose have been performed. It has been shown that the monitor is suitable for monitoring the longitudinal bunch profile behind the first bunch compressor at FLASH. Electron bunch profiles with slopes corresponding to a full width half maximum of about 1.4 ps have been detected. That is the intrinsic resolution limit of the utilized method. (orig.)

  1. A new diagnostic concept for the primary circuit of WWER 1000 reactors

    International Nuclear Information System (INIS)

    Streicher, V.; Liska, J.

    1993-01-01

    The new concept developed by the Skoda and Siemens companies is based on their own experience, the requirements of the Czech Power Board/NPP Temelin Diagnostic Department, and on the research work of various institutes in Czechoslovakia. The development of a complex diagnostic concept is an iterative process and includes parts with different stages of experience and different goals. They can be divided into five groups: PC-based diagnostic systems with continuous or periodic functions, equipment for condition monitoring, PC-based data collectors, studies, analyses and measures which are mandatory for the correct performance and interpretation of the diagnostic systems, and the integration of all subsystems and data acquisition/evaluation units into a Local Area Network with a graphic workstation. (Z.S.) 2 figs., 4 refs

  2. Plant diagnostics in power stations

    International Nuclear Information System (INIS)

    Sturm, A.; Doering, D.

    1985-01-01

    The method of noise diagnostics is dealt with as a part of plant diagnostics in nuclear power stations. The following special applications are presented: (1) The modular noise diagnostics system is used for monitoring primary coolant circuits and detecting abnormal processes due to mechanical vibrations, loose parts or leaks. (2) The diagnostics of machines and plants with antifriction bearings is based on bearing vibration measurements. (3) The measurement of the friction moment by means of acoustic emission analysis is used for evaluating the operational state of slide bearings

  3. Diagnostic imaging in oncology: New challenges and changing strategies

    International Nuclear Information System (INIS)

    Castellino, Ronald A.; Schwartz, Lawrence H.

    1997-01-01

    Diagnostic radiology and nuclear medicine studies, both imaging and therapeutic, play important roles in screening, staging, monitoring of treatment, and in long term surveillance of oncologic patients. Frequently, information from these studies, as well as from ancillary data (such as the clinical examination and laboratory studies) overlap, and it is sometimes unclear which tests and examinations to perform. Current changes in the delivery and funding of health care are prompting all specialties to evaluate their patterns of care. Some of the important questions to be addressed in medical imaging include: Which studies are pertinent at initial staging, e.g., those that impact patient management, serve as important baselines for comparison with subsequent studies, etc? How sensitive and specific are these studies, e.g., when can they obviate the need for more invasive confirmatory exams? What are the critical questions in monitoring response to therapy, e.g., the significance of the 'post treatment residual mass' and ways to elucidate its etiology? Which tests should be performed in surveillance for disease relapse, and how frequently should they be done? Purpose/Objective: To develop a set of guidelines for developing rational approaches for utilizing diagnostic imaging studies

  4. Diagnostic imaging in oncology: New challenges and changing strategies

    International Nuclear Information System (INIS)

    Castellino, Ronald; Schwartz, Lawrence H.

    1996-01-01

    Purpose/Objective: To develop a set of guidelines for developing rational approaches for utilizing diagnostic imaging studies. Diagnostic radiology and nuclear medicine studies, both imaging and therapeutic, play important roles in screening, staging, monitoring of treatment, and in long term surveillance of oncologic patients. Frequently, information from these studies, as well as from ancillary data (such as the clinical examination and laboratory studies) overlap, and it is sometimes unclear which tests and examinations to perform. Current changes in the delivery and funding of health care are prompting all specialties to evaluate their patterns of care. Some of the important questions to be addressed in medical imaging include: Which studies are pertinent at initial staging, e.g., those that impact patient management, serve as important baselines for comparison with subsequent studies, etc? How sensitive and specific are these studies, e.g., when can they obviate the need for more invasive confirmatory exams? What are the critical questions in monitoring response to therapy, e.g., the significance of the 'post treatment residual mass' and ways to elucidate its etiology? Which tests should be performed in surveillance for disease relapse, and how frequently should they be done?

  5. Advance in study of intelligent diagnostic method for nuclear power plant

    International Nuclear Information System (INIS)

    Zhou Gang; Yang Li

    2008-01-01

    The advance of research on the application of three types of intelligent diagnostic approach based on neural network (ANN), fuzzy logic and expert system to the operation status monitoring and fault diagnosis of nuclear power plant (NPP) was reviewed. The research status and characters on status monitoring and fault diagnosis approaches based on neural network, fuzzy logic and expert system for nuclear power plant were analyzed. The development trend of applied research on intelligent diagnostic approaches for nuclear power plant was explored. The analysis results show that the research achievements on intelligent diagnostic approaches based on fuzzy logic and expert system for nuclear power plant are not much relatively. The research of intelligent diagnostic approaches for nuclear power plant concentrate on the aspect of operation status monitoring and fault diagnosis based on neural networks for nuclear power plant. The advancing tendency of intelligent diagnostic approaches for nuclear power plant is the combination of various intelligent diagnostic approaches, the combination of neural network diagnostic approaches and other diagnostic approaches as well as multiple neural network diagnostic approaches. (authors)

  6. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  7. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  8. Integrating policy-based management and SLA performance monitoring

    Science.gov (United States)

    Liu, Tzong-Jye; Lin, Chin-Yi; Chang, Shu-Hsin; Yen, Meng-Tzu

    2001-10-01

    Policy-based management system provides the configuration capability for the system administrators to focus on the requirements of customers. The service level agreement performance monitoring mechanism helps system administrators to verify the correctness of policies. However, it is difficult for a device to process the policies directly because the policies are the management concept. This paper proposes a mechanism to decompose a policy into rules that can be efficiently processed by a device. Thus, the device may process the rule and collect the performance statistics information efficiently; and the policy-based management system may collect these performance statistics information and report the service-level agreement performance monitoring information to the system administrator. The proposed policy-based management system achieves both the policy configuration and service-level agreement performance monitoring requirements. A policy consists of a condition part and an action part. The condition part is a Boolean expression of a source host IP group, a destination host IP group, etc. The action part is the parameters of services. We say that an address group is compact if it only consists of a range of IP address that can be denoted by a pair of IP address and corresponding IP mask. If the condition part of a policy only consists of the compact address group, we say that the policy is a rule. Since a device can efficiently process a compact address and a system administrator prefers to define a range of IP address, the policy-based management system has to translate policy into rules and supplements the gaps between policy and rules. The proposed policy-based management system builds the relationships between VPN and policies, policy and rules. Since the system administrator wants to monitor the system performance information of VPNs and policies, the proposed policy-based management system downloads the relationships among VPNs, policies and rules to the

  9. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-01-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next

  10. Performance monitoring in the medial frontal cortex and related neural networks: From monitoring self actions to understanding others' actions.

    Science.gov (United States)

    Ninomiya, Taihei; Noritake, Atsushi; Ullsperger, Markus; Isoda, Masaki

    2018-04-27

    Action is a key channel for interacting with the outer world. As such, the ability to monitor actions and their consequences - regardless as to whether they are self-generated or other-generated - is of crucial importance for adaptive behavior. The medial frontal cortex (MFC) has long been studied as a critical node for performance monitoring in nonsocial contexts. Accumulating evidence suggests that the MFC is involved in a wide range of functions necessary for one's own performance monitoring, including error detection, and monitoring and resolving response conflicts. Recent studies, however, have also pointed to the importance of the MFC in performance monitoring under social conditions, ranging from monitoring and understanding others' actions to reading others' mental states, such as their beliefs and intentions (i.e., mentalizing). Here we review the functional roles of the MFC and related neural networks in performance monitoring in both nonsocial and social contexts, with an emphasis on the emerging field of a social systems neuroscience approach using macaque monkeys as a model system. Future work should determine the way in which the MFC exerts its monitoring function via interactions with other brain regions, such as the superior temporal sulcus in the mentalizing system and the ventral premotor cortex in the mirror system. Copyright © 2018. Published by Elsevier B.V.

  11. Electronic Performance Monitoring: An Organizational Justice and Concertive Control Perspective.

    Science.gov (United States)

    Alder, G. Stoney; Tompkins, Phillip K.

    1997-01-01

    Applies theories of organizational justice/concertive control to account for contradictions inherent in electronic monitoring of workers by organizations. Argues that results are usually positive when workers are involved in the design and implementation of monitoring systems, and monitoring is restricted to performance-related activities with…

  12. Performance analysis of the TNO TLD individual monitoring service

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van; Julius, H.W.

    1990-01-01

    The purpose of this study was to analyse the performance and to establish the lowest detectable occupational dose (LDOD) of the TNO TL dosemeter, in use for large scale routine individual monitoring since 1983. The TNO individual monitoring service uses three TLD reader systems and over 45000 TL dosemeters, designed to measure H s (0.07) and H p (10). Each reader system is normalised daily and each individual dosemeter is calibrated every ten readout cycles. The performance of the service is monitored by a double blind experimental set-up. A series of 10 routine dosemeters is issued every fortnight, mailed, exposed by staff not involved in the monitoring service, sent back and evaluated. The conclusion of this study is that the lowest detectable occupational dose is less than 0.04 mSv and that the integrated dose at the level of the annual dose limit is measured within 2%. (author)

  13. Towards Modernizing the Characterization of Shock and Detonation Physics Performance via Novel Diagnostics and Tests

    Science.gov (United States)

    Salyer, Terry

    2017-06-01

    For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.

  14. Using method of geotechnical diagnostics for oil and gas pipelines on the base of aerospace monitoring

    International Nuclear Information System (INIS)

    Shirinzade, A.; Gasanov, Kh.; Ragimov, R.; Timofeev, A.

    2008-01-01

    In the paper o the base of aerospatial images of decoding it is studied the problems of using the method of geotechnical diagnostics (GTD) for magistral pipelines. This technique is used for discovering potentially dangerous sections. It has been shown that the processes in geotechnical system have pecular properties on the earth surface which may be identified in terms of aerospace monitoring. Studing these properties one can conclude about state of the system as whole. It is described example of using the GTD method for practical evaluation of magistral pipeline

  15. Diagnostic performance and color overlay pattern in shear wave elastography (SWE) for palpable breast mass.

    Science.gov (United States)

    Park, Jiyoon; Woo, Ok Hee; Shin, Hye Seon; Cho, Kyu Ran; Seo, Bo Kyoung; Kang, Eun Young

    2015-10-01

    The purpose of this study is to evaluate the diagnostic performance of SWE in palpable breast mass and to compare with color overlay pattern in SWE with conventional US and quantitative SWE for assessing palpable breast mass. SWE and conventional breast US were performed in 133 women with 156 palpable breast lesions (81 benign, 75 malignant) between August 2013 to June 2014. Either pathology or periodic imaging surveillance more than 2 years was a reference standard. Existence of previous image was blinded to performing radiologists. US BI-RADS final assessment, qualitative and quantitative SWE measurements were evaluated. Diagnostic performances of grayscale US, SWE and US combined to SWE were calculated and compared. Correlation between pattern classification and quantitative SWE was evaluated. Both color overlay pattern and quantitative SWE improved the specificity of conventional US, from 81.48% to 96.30% (p=0.0005), without improvement in sensitivity. Color overlay pattern was significantly related to all quantitative SWE parameters and malignancy rate (pbreast mass, conventional US combine to SWE improves specificity and reduces the number of biopsies that ultimately yield a benign result. Color overlay pattern classification is more quick and easy and may represent quantitative SWE measurements with similar diagnostic performances. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Electoronic Performance Monitoring in Call Centers: An Ethical Decision Model

    OpenAIRE

    Perkins, David

    2013-01-01

    Ever since it emerged on a widespread basis in the 1990s, electronic performance monitoring of employees has received significant scrutiny in the literature. Call centers have been the focus of many of these studies. This particular study addresses the issue of electronic performance monitoring in call centers from an ethical perspective. The following ethical dilemma is offered: "Is it ethical for a call center manager to evaluate the performance of a call center employee using electronic pe...

  17. 200-BP-1 Prototype Hanford Barrier -- 15 Years of Performance Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Anderson L.; Draper, Kathryn E.; Link, Steven O.; Clayton, Ray E.

    2011-09-30

    Monitoring is an essential component of engineered barrier system design and operation. A composite capacitive cover, including a capillary break and an evapotranspiration (ET) barrier at the Hanford Site, is generating data that can be used to help resolve these issues. The prototype Hanford barrier was constructed over the 216-B-57 Crib in 1994 to evaluate surface-barrier constructability, construction costs, and physical and hydrologic performance at the field scale. The barrier has been routinely monitored between November 1994 and September 1998 as part of a Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) treatability test of barrier performance for the 200 BP 1 Operable Unit. Since FY 1998, monitoring has focused on a more limited set of key water balance, stability, and biotic parameters. In FY 2009, data collection was focused on: (1) water-balance monitoring, consisting of precipitation, runoff, soil moisture storage, and drainage measurements with evapotranspiration calculated by difference; (2) stability monitoring, consisting of asphalt-layer-settlement, basalt-side-slope-stability, and surface-elevation measurements; (3) vegetation dynamics; and (4) animal use. September 2009 marked 15 years since the start of monitoring and the collection of performance data. This report describes the results of monitoring activities during the period October 1, 2008, through September 30, 2009, and summarizes the 15 years of performance data collected from September 1994 through September 2009.

  18. 9 CFR 130.17 - User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for other veterinary... FEES USER FEES § 130.17 User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or at authorized sites. (a) User fees for veterinary diagnostics tests performed at the...

  19. 9 CFR 130.16 - User fees for veterinary diagnostic serology tests performed at NVSL (excluding FADDL) or at...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for veterinary diagnostic serology tests performed at NVSL (excluding FADDL) or at authorized sites. 130.16 Section 130.16 Animals... USER FEES § 130.16 User fees for veterinary diagnostic serology tests performed at NVSL (excluding...

  20. High-Performance Monitoring Architecture for Large-Scale Distributed Systems Using Event Filtering

    Science.gov (United States)

    Maly, K.

    1998-01-01

    Monitoring is an essential process to observe and improve the reliability and the performance of large-scale distributed (LSD) systems. In an LSD environment, a large number of events is generated by the system components during its execution or interaction with external objects (e.g. users or processes). Monitoring such events is necessary for observing the run-time behavior of LSD systems and providing status information required for debugging, tuning and managing such applications. However, correlated events are generated concurrently and could be distributed in various locations in the applications environment which complicates the management decisions process and thereby makes monitoring LSD systems an intricate task. We propose a scalable high-performance monitoring architecture for LSD systems to detect and classify interesting local and global events and disseminate the monitoring information to the corresponding end- points management applications such as debugging and reactive control tools to improve the application performance and reliability. A large volume of events may be generated due to the extensive demands of the monitoring applications and the high interaction of LSD systems. The monitoring architecture employs a high-performance event filtering mechanism to efficiently process the large volume of event traffic generated by LSD systems and minimize the intrusiveness of the monitoring process by reducing the event traffic flow in the system and distributing the monitoring computation. Our architecture also supports dynamic and flexible reconfiguration of the monitoring mechanism via its Instrumentation and subscription components. As a case study, we show how our monitoring architecture can be utilized to improve the reliability and the performance of the Interactive Remote Instruction (IRI) system which is a large-scale distributed system for collaborative distance learning. The filtering mechanism represents an Intrinsic component integrated

  1. The effects of monitoring environment on problem-solving performance.

    Science.gov (United States)

    Laird, Brian K; Bailey, Charles D; Hester, Kim

    2018-01-01

    While effective and efficient solving of everyday problems is important in business domains, little is known about the effects of workplace monitoring on problem-solving performance. In a laboratory experiment, we explored the monitoring environment's effects on an individual's propensity to (1) establish pattern solutions to problems, (2) recognize when pattern solutions are no longer efficient, and (3) solve complex problems. Under three work monitoring regimes-no monitoring, human monitoring, and electronic monitoring-114 participants solved puzzles for monetary rewards. Based on research related to worker autonomy and theory of social facilitation, we hypothesized that monitored (versus non-monitored) participants would (1) have more difficulty finding a pattern solution, (2) more often fail to recognize when the pattern solution is no longer efficient, and (3) solve fewer complex problems. Our results support the first two hypotheses, but in complex problem solving, an interaction was found between self-assessed ability and the monitoring environment.

  2. Method for Evaluating Information to Solve Problems of Control, Monitoring and Diagnostics

    Science.gov (United States)

    Vasil'ev, V. A.; Dobrynina, N. V.

    2017-06-01

    The article describes a method for evaluating information to solve problems of control, monitoring and diagnostics. It is necessary for reducing the dimensionality of informational indicators of situations, bringing them to relative units, for calculating generalized information indicators on their basis, ranking them by characteristic levels, for calculating the efficiency criterion of a system functioning in real time. The design of information evaluation system has been developed on its basis that allows analyzing, processing and assessing information about the object. Such object can be a complex technical, economic and social system. The method and the based system thereof can find a wide application in the field of analysis, processing and evaluation of information on the functioning of the systems, regardless of their purpose, goals, tasks and complexity. For example, they can be used to assess the innovation capacities of industrial enterprises and management decisions.

  3. Climate Prediction Center - Monitoring & Data Index

    Science.gov (United States)

    Weather Service NWS logo - Click to go to the NWS home page Climate Prediction Center Site Map News Oceanic & Atmospheric Monitoring and Data Monitoring Weather & Climate in Realtime Climate Diagnostics Bulletin Preliminary Climate Diagnostics Bulletin Figures Monthly Atmospheric & Sea Surface

  4. In-vitro diagnostic devices introduction to current point-of-care diagnostic devices

    CERN Document Server

    Cheng, Chao-Min; Chen, Chien-Fu

    2016-01-01

    Addressing the origin, current status, and future development of point-of-care diagnostics, and serving to integrate knowledge and tools from Analytical Chemistry, Bioengineering, Biomaterials, and Nanotechnology, this book focusses on addressing the collective and combined needs of industry and academia (including medical schools) to effectively conduct interdisciplinary research. In addition to summarizing and detailing developed diagnostic devices, this book will attempt to point out the possible future trends of development for point-of-care diagnostics using both scientifically based research and practical engineering needs with the aim to help novices comprehensively understand the development of point-of-care diagnostics. This includes demonstrating several common but critical principles and mechanisms used in point-of-care diagnostics that address practical needs (e.g., disease or healthcare monitoring) using two well-developed examples so far: 1) blood glucose meters (via electrochemistry); and, 2) p...

  5. Performance monitoring of GRID superscalar with OCM-G/G-PM: Integration issues

    NARCIS (Netherlands)

    Badia, R.M.; Sirvent, R.; Bubak, M.; Funika, W.; Machner, P.; Gorlatch, S.; Bubak, M.; Priol, T.

    2008-01-01

    In this paper the use of a Grid-enabled system for performance monitoring of GRID superscalar-compliant applications is addressed. Performance monitoring is built on top of the OCM-G monitoring system developed in the EU IST CrossGrid project. A graphical user tool G-PM is used to interpret

  6. Health care sensor--based systems for point of care monitoring and diagnostic applications: a brief survey.

    Science.gov (United States)

    Tsakalakis, Michail; Bourbakis, Nicolaos G

    2014-01-01

    Continuous, real-time remote monitoring through medical point--of--care (POC) systems appears to draw the interest of the scientific community for healthcare monitoring and diagnostic applications the last decades. Towards this direction a significant merit has been due to the advancements in several scientific fields. Portable, wearable and implantable apparatus may contribute to the betterment of today's healthcare system which suffers from fundamental hindrances. The number and heterogeneity of such devices and systems regarding both software and hardware components, i.e sensors, antennas, acquisition circuits, as well as the medical applications that are designed for, is impressive. Objective of the current study is to present the major technological advancements that are considered to be the driving forces in the design of such systems, to briefly state the new aspects they can deliver in healthcare and finally, the identification, categorization and a first level evaluation of them.

  7. In-flight spectral performance monitoring of the Airborne Prism Experiment.

    Science.gov (United States)

    D'Odorico, Petra; Alberti, Edoardo; Schaepman, Michael E

    2010-06-01

    Spectral performance of an airborne dispersive pushbroom imaging spectrometer cannot be assumed to be stable over a whole flight season given the environmental stresses present during flight. Spectral performance monitoring during flight is commonly accomplished by looking at selected absorption features present in the Sun, atmosphere, or ground, and their stability. The assessment of instrument performance in two different environments, e.g., laboratory and airborne, using precisely the same calibration reference, has not been possible so far. The Airborne Prism Experiment (APEX), an airborne dispersive pushbroom imaging spectrometer, uses an onboard in-flight characterization (IFC) facility, which makes it possible to monitor the sensor's performance in terms of spectral, radiometric, and geometric stability in flight and in the laboratory. We discuss in detail a new method for the monitoring of spectral instrument performance. The method relies on the monitoring of spectral shifts by comparing instrument-induced movements of absorption features on ground and in flight. Absorption lines originate from spectral filters, which intercept the full field of view (FOV) illuminated using an internal light source. A feature-fitting algorithm is used for the shift estimation based on Pearson's correlation coefficient. Environmental parameter monitoring, coregistered on board with the image and calibration data, revealed that differential pressure and temperature in the baffle compartment are the main driving parameters explaining the trend in spectral performance deviations in the time and the space (across-track) domains, respectively. The results presented in this paper show that the system in its current setup needs further improvements to reach a stable performance. Findings provided useful guidelines for the instrument revision currently under way. The main aim of the revision is the stabilization of the instrument for a range of temperature and pressure conditions

  8. Limerick Nuclear Generating Station vibration monitoring system

    International Nuclear Information System (INIS)

    Mikulski, R.

    1988-01-01

    Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed

  9. Diagnostic performance of cytology for assessment of hepatic lipid content in dairy cattle.

    Science.gov (United States)

    Fry, M M; Yao, B; Ríos, C; Wong, C; Mann, S; McArt, J A A; Nydam, D V; Leal Yepes, F A; Viesselmann, L; Geick, A; Goldin, K; Jordan, A; Behling-Kelly, E

    2018-02-01

    The objective of our study was to characterize the diagnostic performance of cytology for assessing hepatic lipid content (HLC) in dairy cows by comparing microscopic evaluation of lipid vacuolation in touch imprint slide preparations of liver biopsies with quantitative measurement of triglyceride concentration ([TG]; mg/mg of wet weight) in paired biopsy samples. Our study also sought to compare the diagnostic performance of liver cytology, plasma nonesterified fatty acid concentration ([NEFA]), and plasma β-hydroxybutyrate concentration ([BHB]) derived from a measurement performed on whole blood, for assessing HLC. Chemical extraction of TG from liver tissue remains the gold standard for quantifying HLC, largely because available blood tests, although useful for detecting some types of pathology, such as increased lipid mobilization, ketosis, or hepatocellular injury, are nonspecific as to etiology. Veterinary practitioners can sample bovine liver for cytological evaluation in a fast, minimally invasive, and inexpensive manner. Thus, if highly predictive of HLC, cytology would be a practical diagnostic tool for dairy veterinarians. In our study, liver biopsy samples from Holstein cows (219 samples from 105 cows: 52 from cows 2 to 20 d prepartum, 105 from cows 0 to 10 d in milk, 62 from cows 18 to 25 d in milk) were used to prepare cytology slides and to quantify [TG] using the Folch extraction method followed by the Hantzch condensation reaction and spectrophotometric measurement. An ordinal scale (0-4) based on amount of hepatocellular cytoplasm occupied by discrete clear vacuoles was used by 3 blinded, independent observers to rank HLC in Wright-Giemsa-stained slides. Interobserver agreement in cytology scoring was good. Corresponding plasma [NEFA] and [BHB] measurements were available for 187 and 195 of the 219 samples, respectively. Liver [TG] correlated more strongly with cytology score than with NEFA or BHB, and receiver operating characteristic curve

  10. 10 CFR 600.341 - Monitoring and reporting program and financial performance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Monitoring and reporting program and financial performance. 600.341 Section 600.341 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS FINANCIAL... Organizations Post-Award Requirements § 600.341 Monitoring and reporting program and financial performance. (a...

  11. A beam diagnostic system for ELSA

    International Nuclear Information System (INIS)

    Schillo, M.; Althoff, K.H.; Drachenfels, W.; Goetz, T.; Husmann, D.; Neckenig, M.; Picard, M.; Schittko, F.J.; Schauerte, W.; Wenzel, J.

    1991-01-01

    A beam diagnostic system, which is based on capacitive beam-position monitors combined with fast electronics, has been developed for the Bonn ELectron Stretcher Accelerator ELSA. The position signal of each monitor is digitized at an adjustable sampling rate (max.: 10 MHz) and the most recent 8192 position and intensity values are buffered. This allows a wide range of different beam diagnostic measurements. The main purpose is the closed-orbit correction, which can be carried out on various time scales. To optimize the duty factor of the extracted beam, the system can also be used as a fast relative intensity monitor resolving the intensity distribution of the bunches or of the injected beam. It is designed to support betatron tune and phase measurements with very high accuracy, offering the choice to select any of the beam position monitors. This enables the measuring of many optical parameters. Furthermore any pair of suitable monitors can be used for experimental particle tracking or phase space measurements

  12. Beam diagnostic instruments of TARN

    International Nuclear Information System (INIS)

    Watanabe, Shin-ichi.

    1987-09-01

    The paper summarizes the beam diagnostic instruments of the low energy ion accumulation ring; TARN. With these monitors, position, profiles, bunch structure, intensity, emittance and momentum spread were measured to evaluate the injection and stacking experiments. The monitors provide the sensitivity of a few μA for the nondestructive and a few nA for the destructive monitors. Discussions on monitor probe and electronics are presented on the basis of an achievement of the beam stacking experiments. (author)

  13. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  14. 9 CFR 130.15 - User fees for veterinary diagnostic isolation and identification tests performed at NVSL...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for veterinary diagnostic isolation and identification tests performed at NVSL (excluding FADDL) or other authorized site. 130.15... AGRICULTURE USER FEES USER FEES § 130.15 User fees for veterinary diagnostic isolation and identification...

  15. Point -of -care testing (POCT) in molecular diagnostics: Performance evaluation of GeneXpert HCV RNA test in diagnosing and monitoring of HCV infection.

    Science.gov (United States)

    Gupta, Ekta; Agarwala, Pragya; Kumar, Guresh; Maiwall, Rakhi; Sarin, Shiv Kumar

    2017-03-01

    Molecular testing at the point-of-care may turn out to be game changer for HCV diagnosis and treatment monitoring, through increased sensitivity, reduced turnaround time, and ease of performance. One such assay GeneXpert ® has recently been released. Comparative analysis between performances of GeneXpert ® and Abbott HCV-RNA was done. 174 HCV infected patients were recruited and, one time plasma samples from 154 patients and repeated samples from 20 patients, obtained at specific treatment time-points (0, 4, 12 and 24) weeks were serially re-tested on Xpert ® . Genotype 3 was the commonest, seen in 80 (66%) of the cases, genotype 1 in 34 (28.3%), genotype 4 in 4 (3.3%) and genotypes 2 and 5 in 1 (0.8%) each. Median HCV RNA load was 4.69 log 10 (range: 0-6.98log 10 ) IU/ml. Overall a very good correlation was seen between the two assays (R 2 =0.985), concordance of the results between the assays was seen in 138 samples (89.6%). High and low positive standards were tested ten times on Xpert ® to evaluate the precision and the coefficient of variation was 0.01 for HPC and 0.07 for the LPC. Monitoring of patients on two different regimes of treatment, pegylated interferon plus ribavirin and sofosbuvir plus ribavirin was done by both the systems at baseline, 4, 12 and 24 weeks. Perfect correlation between the assays in the course of therapy at different treatment time- point in genotypes 3 and 1 was seen. The study demonstrates excellent performance of the Xpert ® HCV assay in viral load assessment and in treatment course monitoring consistency. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Acoustic and vibration monitoring systems and its place in the general conception of NPP diagnostics

    International Nuclear Information System (INIS)

    Dmitriev, V.; Kudryavtsev, B.; Morozov, S.; Finkel, B.

    1993-01-01

    Concept of diagnostics as a matter is an identification of defects and malfunctions in operating equipment by analyzing some data containing the information about these defects or malfunctions, but received without their direct observation. The direct observation of some parameters may be impossible in principle (for example, coolant saturation temperature), or because of inaccessibility for its measuring (for example, temperature of fuel elements), or because of the absence of a suitable sensor at a proper place. And, on the contrary, in some cases there is too much information for its simple interpretation. This report describes various monitoring systems of reactor components.Application is made to a pwr type reactor

  17. SCALEA-G: A Unified Monitoring and Performance Analysis System for the Grid

    Directory of Open Access Journals (Sweden)

    Hong-Linh Truong

    2004-01-01

    Full Text Available This paper describes SCALEA-G, a unified monitoring and performance analysis system for the Grid. SCALEA-G is implemented as a set of grid services based on the Open Grid Services Architecture (OGSA. SCALEA-G provides an infrastructure for conducting online monitoring and performance analysis of a variety of Grid services including computational and network resources, and Grid applications. Both push and pull models are supported, providing flexible and scalable monitoring and performance analysis. Source code and dynamic instrumentation are implemented to perform profiling and monitoring of Grid applications. A novel instrumentation request language for dynamic instrumentation and a standardized intermediate representation for binary code have been developed to facilitate the interaction between client and instrumentation services.

  18. Performance Monitoring in Children Following Traumatic Brain Injury Compared to Typically Developing Children

    Directory of Open Access Journals (Sweden)

    Amy A. Wilkinson PhD

    2017-10-01

    Full Text Available Children with traumatic brain injury are reported to have deficits in performance monitoring, but the mechanisms underlying these deficits are not well understood. Four performance monitoring hypotheses were explored by comparing how 28 children with traumatic brain injury and 28 typically developing controls (matched by age and sex performed on the stop-signal task. Control children slowed significantly more following incorrect than correct stop-signal trials, fitting the error monitoring hypothesis. In contrast, the traumatic brain injury group showed no performance monitoring difference with trial types, but significant group differences did not emerge, suggesting that children with traumatic brain injury may not perform the same way as controls.

  19. Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses.

    Science.gov (United States)

    Kim, Hana; Youk, Ji Hyun; Gweon, Hye Mi; Kim, Jeong-Ah; Son, Eun Ju

    2013-08-01

    To compare the diagnostic performance of qualitative shear-wave elastography (SWE) according to three different color map opacities for breast masses 101 patients aged 21-77 years with 113 breast masses underwent B-mode US and SWE under three different color map opacities (50%, 19% and 100%) before biopsy or surgery. Following SWE features were reviewed: visual pattern classification (pattern 1-4), color homogeneity (Ehomo) and six-point color score of maximum elasticity (Ecol). Combined with B-mode US and SWE, the likelihood of malignancy (LOM) was also scored. The area under the curve (AUC) was obtained by ROC curve analysis to assess the diagnostic performance under each color opacity. A visual color pattern, Ehomo, Ecol and LOM scoring were significantly different between benign and malignant lesions under all color opacities (Pbreast lesion under all color opacities. The difference in color map opacity did not significantly influence diagnostic performance of SWE. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. FINAL REPORT: Building Performance Optimization while Empowering Occupants Toward Environmentally Sustainable Behavior through Continuous Monitoring and Diagnostics

    Science.gov (United States)

    2016-12-05

    Federal Energy Management Program FM Facility Manager GHG Green House Gases HASP Health and Safety Plan HVAC Heating Ventilation and... workplace energy efficiency enhancement by the DOD personnel. 2.1.2 ID-F Intelligent Dashboards for Facility Managers Creation of the Base Building...demonstration project. The first technology, ‘ID-F,’ targets building facility managers and allows real time diagnostics for BAS systems with features

  1. Acoustic multivariate condition monitoring - AMCM

    Energy Technology Data Exchange (ETDEWEB)

    Rosenhave, P E [Vestfold College, Maritime Dept., Toensberg (Norway)

    1998-12-31

    In Norway, Vestfold College, Maritime Department presents new opportunities for non-invasive, on- or off-line acoustic monitoring of rotating machinery such as off-shore pumps and diesel engines. New developments within acoustic sensor technology coupled with chemometric data analysis of complex signals now allow condition monitoring of hitherto unavailable flexibility and diagnostic specificity. Chemometrics paired with existing knowledge yields a new and powerful tool for condition monitoring. By the use of multivariate techniques and acoustics it is possible to quantify wear and tear as well as predict the performance of working components in complex machinery. This presentation describes the AMCM method and one result of a feasibility study conducted onboard the LPG/C `Norgas Mariner` owned by Norwegian Gas Carriers as (NGC), Oslo. (orig.) 6 refs.

  2. Acoustic multivariate condition monitoring - AMCM

    Energy Technology Data Exchange (ETDEWEB)

    Rosenhave, P.E. [Vestfold College, Maritime Dept., Toensberg (Norway)

    1997-12-31

    In Norway, Vestfold College, Maritime Department presents new opportunities for non-invasive, on- or off-line acoustic monitoring of rotating machinery such as off-shore pumps and diesel engines. New developments within acoustic sensor technology coupled with chemometric data analysis of complex signals now allow condition monitoring of hitherto unavailable flexibility and diagnostic specificity. Chemometrics paired with existing knowledge yields a new and powerful tool for condition monitoring. By the use of multivariate techniques and acoustics it is possible to quantify wear and tear as well as predict the performance of working components in complex machinery. This presentation describes the AMCM method and one result of a feasibility study conducted onboard the LPG/C `Norgas Mariner` owned by Norwegian Gas Carriers as (NGC), Oslo. (orig.) 6 refs.

  3. Quality Assurance in Individual Monitoring: 10 Years of Performance Monitoring of the TLD Based TNO Individual Monitoring Service (invited paper)

    Energy Technology Data Exchange (ETDEWEB)

    Dijk, J.W.E. van

    1998-07-01

    The QA subscription forms the nucleus of the Quality Assurance (QA) programme of the TLD-based Individual Monitoring Service of TNO-CSD. This QA subscription is the subscription of a dummy customer to the service. As this customer is treated exactly like a normal customer, all aspects of the service are monitored by the QA subscription. An overview is given of 10 years of monitoring the performance of the service. Various improvements over the past decade have resulted in a standard deviation in a low dose measurement of 0.01 mSv and a relative standard deviation at higher doses of 5%. These figures represent the performance under routine circumstances and thus include variations due to variations in the natural background from place to place and, for example, due to transport. (author)

  4. Quality Assurance in Individual Monitoring: 10 Years of Performance Monitoring of the TLD Based TNO Individual Monitoring Service (invited paper)

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van

    1998-01-01

    The QA subscription forms the nucleus of the Quality Assurance (QA) programme of the TLD-based Individual Monitoring Service of TNO-CSD. This QA subscription is the subscription of a dummy customer to the service. As this customer is treated exactly like a normal customer, all aspects of the service are monitored by the QA subscription. An overview is given of 10 years of monitoring the performance of the service. Various improvements over the past decade have resulted in a standard deviation in a low dose measurement of 0.01 mSv and a relative standard deviation at higher doses of 5%. These figures represent the performance under routine circumstances and thus include variations due to variations in the natural background from place to place and, for example, due to transport. (author)

  5. The Effects of Fatigue From Overnight Shifts on Radiology Search Patterns and Diagnostic Performance.

    Science.gov (United States)

    Hanna, Tarek N; Zygmont, Matthew E; Peterson, Ryan; Theriot, David; Shekhani, Haris; Johnson, Jamlik-Omari; Krupinski, Elizabeth A

    2018-01-20

    The aim of this study was to assess the effect of overnight shifts (ONS) on radiologist fatigue, visual search pattern, and diagnostic performance. This experimental study was approved by the institutional review board. Twelve radiologists (five faculty members and seven residents) each completed two sessions: one during a normal workday ("not fatigued") and another in the morning after an ONS ("fatigued"). Each radiologist completed the Swedish Occupational Fatigue Inventory. During each session, radiologists viewed 20 bone radiographs consisting of normal and abnormal findings. Viewing time, diagnostic confidence, and eye-tracking data were recorded. Swedish Occupational Fatigue Inventory results demonstrated worsening in all five variables (lack of energy, physical exertion, physical discomfort, lack of motivation, and sleepiness) after ONS (P radiologists were more fatigued with worse diagnostic performance, a 45% increase in view time per case, a 60% increase in total gaze fixations, and a 34% increase in time to fixate on the fracture. The effects of fatigue were more pronounced in residents. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  6. Development of an air-operated actuator performance monitoring system for regulatory usage

    International Nuclear Information System (INIS)

    Sung, K. Y.; Kwon, S. J.

    2004-01-01

    The performance monitoring system of air-operated actuators for regulatory usage has been being developed. Essential elements and operating parameters affecting the actuator performance have been investigated to provide basic information for system development. The monitoring system including an air-operated actuator testing facility and analysis softwares for monitoring and evaluation are also introduced in this paper. As a result of simulated tests, it was known that the system could be a useful tool for the effective monitoring of actuator performance change and fault conditions. This system would be applied to regulatory inspection for utility's data validation and to the training of regulatory staff in future after some modification and expansion

  7. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 16

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, Imre; Dykin, Victor; Jonsson, Anders; Demaziere, Christophe (Chalmers Univ. of Technology, Dept. of Nuclear Engineering, Goeteborg (Sweden))

    2010-12-15

    This report gives an account of the work performed by the Dept. of Nuclear Engineering, Chalmers Univ. of Technology, in the frame of a research contract with the Swedish Radiation Safety Authority (SSM), contract No. SSM 2009/2093. The present report is based on work performed by Imre Pazsit, Victor Dykin, Anders Jonsson and Christophe Demaziere, with Imre Pazsit being the project leader. This report describes the results obtained during Stage 16 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of Stage 1 and 2 (SKI Report 95:14 and 96:50, Pazsit et al. 1995, 1996). Results up to Stage 15 were reported in (Pazsit et al. 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2003a, 2003b; Demaziere et al, 2004; Sunde et al, 2006; Pazsit et al. 2008, 2009). A brief proposal for the continuation of this program in Stage 17 is also given at the end of the report. The program executed in Stage 16 consists of four parts as follows: - An overview of the present status of experience with BWR stability; - An investigation of the significance of the properties of the noise source for BWR instability; - Study of the dynamics of molten salt systems: construction of the adjoint and calculating the space dependent noise induced by propagating perturbations in the fuel; - A specific study of some novel methods of analysis of non-linear and non-stationary processes

  8. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 16

    International Nuclear Information System (INIS)

    Pazsit, Imre; Dykin, Victor; Jonsson, Anders; Demaziere, Christophe

    2010-12-01

    This report gives an account of the work performed by the Dept. of Nuclear Engineering, Chalmers Univ. of Technology, in the frame of a research contract with the Swedish Radiation Safety Authority (SSM), contract No. SSM 2009/2093. The present report is based on work performed by Imre Pazsit, Victor Dykin, Anders Jonsson and Christophe Demaziere, with Imre Pazsit being the project leader. This report describes the results obtained during Stage 16 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of Stage 1 and 2 (SKI Report 95:14 and 96:50, Pazsit et al. 1995, 1996). Results up to Stage 15 were reported in (Pazsit et al. 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2003a, 2003b; Demaziere et al, 2004; Sunde et al, 2006; Pazsit et al. 2008, 2009). A brief proposal for the continuation of this program in Stage 17 is also given at the end of the report. The program executed in Stage 16 consists of four parts as follows: - An overview of the present status of experience with BWR stability; - An investigation of the significance of the properties of the noise source for BWR instability; - Study of the dynamics of molten salt systems: construction of the adjoint and calculating the space dependent noise induced by propagating perturbations in the fuel; - A specific study of some novel methods of analysis of non-linear and non-stationary processes

  9. Non intrusive check valve diagnostics at Bruce A

    International Nuclear Information System (INIS)

    Marsch, S.P.

    1997-01-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  10. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  11. A FRAMEWORK FOR PERFORMANCE EVALUATION AND MONITORING OF PUBLIC HEALTH PROGRAM USING COMPOSITE PERFORMANCE INDEX

    Directory of Open Access Journals (Sweden)

    Susanta Kumar Gauri

    2017-12-01

    Full Text Available A public health program (PHP taken up by the government of a country refers to all organized measures to prevent disease and promote health among the population, by providing different planned cares/services to the people. Usually, the target population for different PHP are different. The basic requirement for success of a PHP is to ensure that all the planned cares/services are reached to each member of the target population. Therefore, the important performance measures for a PHP are the implementation status of all the planned cares/services under the PHP. However, management and monitoring of a PHP become quite difficult by interpreting separately the information contained in a large number of performance measures. Therefore, usually a metric, called composite performance index (CPI, is evaluated to understand the overall performance of a PHP. However, due a scaling operation involved in the CPI computation procedure, the CPI value does not reveal the true overall implementation status of a PHP and consequently, it is effective for management of a PHP. This paper presents a new approach for CPI computation, in which scaling/normalization of the performance variables is not required and therefore, it can be used for monitoring the true overall implementation status of a PHP in a region. A systematic approach for monitoring a PHP using the CPI values is proposed and applied for monitoring the maternal and child healthcare (MCH program. The results are found effective towards continuous improvement of implementation status.

  12. Exercise echocardiography or exercise SPECT imaging? - A meta-analysis of diagnostic test performance

    NARCIS (Netherlands)

    Fleischmann, KE; Hunink, MGM; Kuntz, KM; Douglas, PS

    1998-01-01

    Context.-Cardiac imaging has advanced rapidly, providing clinicians with several choices for evaluating patients with suspected coronary artery disease, but few studies compare modalities directly. .-To review the contemporary literature and to compare the diagnostic performance of exercise

  13. ADVANCED MONITORING TO IMPROVE COMBUSTION TURBINE/COMBINED CYCLE CT/(CC) RELIABILITY, AVAILABILITY AND MAINTAINABILITY (RAM)

    Energy Technology Data Exchange (ETDEWEB)

    Leonard Angello

    2003-09-30

    Power generators are concerned with the maintenance costs associated with the advanced turbines that they are purchasing. Since these machines do not have fully established operation and maintenance (O&M) track records, power generators face financial risk due to uncertain future maintenance costs. This risk is of particular concern, as the electricity industry transitions to a competitive business environment in which unexpected O&M costs cannot be passed through to consumers. These concerns have accelerated the need for intelligent software-based diagnostic systems that can monitor the health of a combustion turbine in real time and provide valuable information on the machine's performance to its owner/operators. Such systems would interpret sensor and instrument outputs, correlate them to the machine's condition, provide interpretative analyses, forward projections of servicing intervals, estimate remaining component life, and identify faults. EPRI, Impact Technologies, Boyce Engineering, and Progress Energy have teamed to develop a suite of intelligent software tools integrated with a diagnostic monitoring platform that will, in real time, interpret data to assess the ''total health'' of combustion turbines. The Combustion Turbine Health Management System (CTHM) will consist of a series of dynamic link library (DLL) programs residing on a diagnostic monitoring platform that accepts turbine health data from existing monitoring instrumentation. The CTHM system will be a significant improvement over currently available techniques for turbine monitoring and diagnostics. CTHM will interpret sensor and instrument outputs, correlate them to a machine's condition, provide interpretative analyses, project servicing intervals, and estimate remaining component life. In addition, it will enable real-time anomaly detection and diagnostics of performance and mechanical faults, enabling power producers to more accurately predict critical

  14. Rapid and sensitive detection of Yersinia pestis using amplification of plague diagnostic bacteriophages monitored by real-time PCR.

    Directory of Open Access Journals (Sweden)

    Kirill V Sergueev

    Full Text Available BACKGROUND: Yersinia pestis, the agent of plague, has caused many millions of human deaths and still poses a serious threat to global public health. Timely and reliable detection of such a dangerous pathogen is of critical importance. Lysis by specific bacteriophages remains an essential method of Y. pestis detection and plague diagnostics. METHODOLOGY/PRINCIPAL FINDINGS: The objective of this work was to develop an alternative to conventional phage lysis tests--a rapid and highly sensitive method of indirect detection of live Y. pestis cells based on quantitative real-time PCR (qPCR monitoring of amplification of reporter Y. pestis-specific bacteriophages. Plague diagnostic phages phiA1122 and L-413C were shown to be highly effective diagnostic tools for the detection and identification of Y. pestis by using qPCR with primers specific for phage DNA. The template DNA extraction step that usually precedes qPCR was omitted. phiA1122-specific qPCR enabled the detection of an initial bacterial concentration of 10(3 CFU/ml (equivalent to as few as one Y. pestis cell per 1-microl sample in four hours. L-413C-mediated detection of Y. pestis was less sensitive (up to 100 bacteria per sample but more specific, and thus we propose parallel qPCR for the two phages as a rapid and reliable method of Y. pestis identification. Importantly, phiA1122 propagated in simulated clinical blood specimens containing EDTA and its titer rise was detected by both a standard plating test and qPCR. CONCLUSIONS/SIGNIFICANCE: Thus, we developed a novel assay for detection and identification of Y. pestis using amplification of specific phages monitored by qPCR. The method is simple, rapid, highly sensitive, and specific and allows the detection of only live bacteria.

  15. Handbook of Coherent-Domain Optical Methods Biomedical Diagnostics, Environmental Monitoring, and Materials Science

    CERN Document Server

    2013-01-01

    This Handbook provides comprehensive coverage of laser and coherent-domain methods as applied to biomedicine, environmental monitoring, and materials science. Worldwide leaders in these fields describe the fundamentals of light interaction with random media and present an overview of basic research. The latest results on coherent and polarization properties of light scattered by random media, including tissues and blood, speckles formation in multiple scattering media, and other non-destructive interactions of coherent light with rough surfaces and tissues, allow the reader to understand the principles and applications of coherent diagnostic techniques. The expanded second edition has been thoroughly updated with particular emphasis on novel coherent-domain techniques and their applications in medicine and environmental science. Volume 1 describes state-of-the-art methods of coherent and polarization optical imaging, tomography and spectroscopy; diffusion wave spectroscopy; elastic, quasi-elastic and inelasti...

  16. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    Science.gov (United States)

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  17. Computerised decision support systems in order communication for diagnostic, screening or monitoring test ordering: systematic reviews of the effects and cost-effectiveness of systems.

    Science.gov (United States)

    Main, C; Moxham, T; Wyatt, J C; Kay, J; Anderson, R; Stein, K

    2010-10-01

    conducted on a range of medical, social science and economic databases. The review was undertaken using standard systematic review methods, with studies being screened for inclusion, data extracted and quality assessed by two reviewers. Results were broadly grouped according to the type of CDSS intervention and study design where possible. These were then combined using a narrative synthesis with relevant quantitative results tabulated. Results of the studies included in review were highly mixed and equivocal, often both within and between studies, but broadly showed a beneficial impact of the use of CDSS in conjunction with OCS over and above OCS alone. Overall, if the findings of both primary and secondary outcomes are taken into account, then CDSS significantly improved practitioner performance in 15 out of 24 studies (62.5%). Only two studies covered the cost-effectiveness of CDSS: a Dutch study reported a mean cost decrease of 3% for blood tests orders (639 euros) in each of the intervention clinics compared with a 2% (208 euros) increase in control clinics in test costs; and a Spanish study reported a significant increase in the cost of laboratory tests from 41.8 euros per patient per annum to 47.2 euros after implementation of the system. The response rate from the survey of manufacturers and suppliers was extremely low at only 17% and much of the feedback was classified as being commercial-in-confidence (CIC). No studies were identified which assessed the features of CDSS that are associated with clinician or patient acceptance of CDSS in OCS in the test ordering process and only limited data was available on the cost-effectiveness of CDSS plus OCS compared with OCS alone and the findings highly specific. Although CDSS appears to have a potentially small positive impact on diagnostic, screening or monitoring test ordering, the majority of studies come from a limited number of institutions in the USA. If the findings of both primary and secondary outcomes are taken

  18. Transformer engineering design, technology, and diagnostics

    CERN Document Server

    Kulkarni, SV

    2012-01-01

    Transformer Engineering: Design, Technology, and Diagnostics, Second Edition helps you design better transformers, apply advanced numerical field computations more effectively, and tackle operational and maintenance issues. Building on the bestselling Transformer Engineering: Design and Practice, this greatly expanded second edition also emphasizes diagnostic aspects and transformer-system interactions. What's New in This Edition Three new chapters on electromagnetic fields in transformers, transformer-system interactions and modeling, and monitoring and diagnostics An extensively revised chap

  19. UCIMS: Advances in geotechnical construction and performance monitoring

    Directory of Open Access Journals (Sweden)

    Raphael Siebenmann

    2015-04-01

    Full Text Available The Crossrail project currently under construction in Central London has been described as “The Big Dig on Steroids”, obviously referencing the Central Artery/Tunnel project in Boston completed in 2007. To address the multiple demands for timely construction performance monitoring, Crossrail envisioned the underground construction information management system (UCIMS to monitor construction progress and structural health along the entire route, with a network of geotechnical instruments (i.e. slope inclinometers, extensometers, piezometers, etc. and tunnel boring machine (TBM position information. The UCIMS is a geospatially referenced relational database that was developed using an open source geographic information system (GIS that allowed all stakeholders near immediate feedback of construction performance. The purpose of this article is to provide a brief history of geotechnical and structural monitoring software, to describe the structure and operation of the UCIMS, and to demonstrate how the functionality afforded by this system provided the requisite feedback to the stakeholders. Examples will be given regarding how the data management and visualization concepts incorporated into the UCIMS advanced the geotechnical construction industry.

  20. Preliminary Analysis of Remote Monitoring and Robotic Concepts for Performance Confirmation

    International Nuclear Information System (INIS)

    McAffee, D.A.

    1997-01-01

    As defined in 10 CFR Part 60.2, Performance Confirmation is the ''program of tests, experiments and analyses which is conducted to evaluate the accuracy and adequacy of the information used to determine with reasonable assurance that the performance objectives for the period after permanent closure will be met''. The overall Performance Confirmation program begins during site characterization and continues up to repository closure. The main purpose of this document is to develop, explore and analyze initial concepts for using remotely operated and robotic systems in gathering repository performance information during Performance Confirmation. This analysis focuses primarily on possible Performance Confirmation related applications within the emplacement drifts after waste packages have been emplaced (post-emplacement) and before permanent closure of the repository (preclosure). This will be a period of time lasting approximately 100 years and basically coincides with the Caretaker phase of the project. This analysis also examines, to a lesser extent, some applications related to Caretaker operations. A previous report examined remote handling and robotic technologies that could be employed during the waste package emplacement phase of the project (Reference 5.1). This analysis is being prepared to provide an early investigation of possible design concepts and technical challenges associated with developing remote systems for monitoring and inspecting activities during Performance Confirmation. The writing of this analysis preceded formal development of Performance Confirmation functional requirements and program plans and therefore examines, in part, the fundamental Performance Confirmation monitoring needs and operating conditions. The scope and primary objectives of this analysis are to: (1) Describe the operating environment and conditions expected in the emplacement drifts during the preclosure period. (Presented in Section 7.2). (2) Identify and discuss the

  1. Passive performance monitoring and traffic characteristics on the SLAC internet border

    International Nuclear Information System (INIS)

    Logg, C.; Cottrell, L.

    2001-01-01

    Understanding how the Internet is used by HEP is critical to optimizing the performance of the inter-lab computing environment. Typically use requirements have been defined by discussions between collaborators. However, later analysis of the actual traffic has show this is often misunderstood and actual use is significantly different to that predicted. Passive monitoring of the real traffic provides insight into the true communications requirements and the performance of a large number of inter-communicating nodes. It may be useful in identifying performance problems that are due to factors other than Internet congestion, especially when compared to other methods such as active monitoring where traffic is generated specifically to measure its performance. Controlled active monitoring between dedicated servers often gives an indication of what can be achieved on a network. Passive monitoring of the real traffic gives a picture of the true performance. The authors will discuss the method and results of collecting and analyzing flows of data obtained from the SLAC Internet border. The insights this has brought to understanding the network will be reviewed and the benefit it can bring to engineering networks will be discussed

  2. Substantia nigra fractional anisotropy is not a diagnostic biomarker of Parkinson's disease: A diagnostic performance study and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Fabiana C.C.; Vieira, Gilson; Lucato, Leandro T.; Leite, Claudia C.; Pastorello, Bruno F.; Otaduy, Maria C.G.; Chaim, Khallil T.; Campanholo, Kenia R. [University of Sao Paulo, LIM-44, Department of Radiology, Sao Paulo, SP (Brazil); Sato, Joao R. [University of Sao Paulo, LIM-44, Department of Radiology, Sao Paulo, SP (Brazil); Universidade Federal do ABC, Center of Mathematics, Computation and Cognition, Santo Andre (Brazil); Bor-Seng-Shu, Edson; Novaes, Natalia P. [Hospital Israelita Albert Einstein, Sao Paulo (Brazil); University of Sao Paulo, Department of Neurology, Sao Paulo (Brazil); Magalhaes Melo, Luciano; Goncalves, Marcia R.; Reis Barbosa, Egberto [University of Sao Paulo, Department of Neurology, Sao Paulo (Brazil); Pereira do Nascimento, Felipe Barjud; Amaro, Edson [University of Sao Paulo, LIM-44, Department of Radiology, Sao Paulo, SP (Brazil); Hospital Israelita Albert Einstein, Sao Paulo (Brazil); Jacobsen Teixeira, Manoel [University of Sao Paulo, Department of Neurosurgery, Sao Paulo (Brazil); Cardoso, Ellison Fernando [University of Sao Paulo, LIM-44, Department of Radiology, Sao Paulo, SP (Brazil); Hospital Israelita Albert Einstein, Sao Paulo (Brazil); Institute of Mathematics and Statistics University of Sao Paulo (IME-USP), Sao Paulo (Brazil)

    2017-06-15

    Our goal was to estimate the diagnostic accuracy of substantia nigra fractional anisotropy (SN-FA) for Parkinson's disease (PD) diagnosis in a sample similar to the clinical setting, including patients with essential tremor (ET) and healthy controls (HC). We also performed a systematic review and meta-analysis to estimate mean change in SN-FA induced by PD and its diagnostic accuracy. Our sample consisted of 135 subjects: 72 PD, 21 ET and 42 HC. To address inter-scanner variability, two 3.0-T MRI scans were performed. MRI results of this sample were pooled into a meta-analysis that included 1,432 subjects (806 PD and 626 HC). A bivariate model was used to evaluate diagnostic accuracy measures. In our sample, we did not observe a significant effect of disease on SN-FA and it was uninformative for diagnosis. The results of the meta-analysis estimated a 0.03 decrease in mean SN-FA in PD relative to HC (CI: 0.01-0.05). However, the discriminatory capability of SN-FA to diagnose PD was low: pooled sensitivity and specificity were 72 % (CI: 68-75) and 63 % (CI: 58-70), respectively. There was high heterogeneity between studies (I{sup 2} = 91.9 %). SN-FA cannot be used as an isolated measure to diagnose PD. (orig.)

  3. Automated diagnostic kiosk for diagnosing diseases

    Science.gov (United States)

    Regan, John Frederick; Birch, James Michael

    2014-02-11

    An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

  4. Functional MRI in schizophrenia. Diagnostics and therapy monitoring of cognitive deficits of schizophrenic patients by functional MRI

    International Nuclear Information System (INIS)

    Furtner, J.; Prayer, D.; Sachs, G.

    2010-01-01

    Cognitive impairments are core psychopathological components of the symptomatic of schizophrenic patients. These dysfunctions are generally related to attention, executive functions and memory. This report provides information on the importance of using functional magnetic resonance imaging (fMRI) for the diagnostics and therapy monitoring of the different subtypes of cognitive dysfunctions. Furthermore, it describes the typical differences in the activation of individual brain regions between schizophrenic patients and healthy control persons. This information should be helpful in identifying the deficit profile of each patient and create an individual therapy plan. (orig.) [de

  5. Experience with diagnostic instrumentation in nuclear power plants

    International Nuclear Information System (INIS)

    Gopal, R.; Ciaramitaro, W.

    1977-01-01

    Over the past several years, Westinghouse has developed a coordinated system of on-line diagnostic instrumentation for the acquisition and analysis of data for diagnostics and incipient failure detection of critical plant equipment and systems. Primary motivation for this work is to improve NSSS availability and Maintainability through the detection of malfunctions at their inception. These systems encompass the following areas: (1) Vibration Monitoring System for detection of changes in vibrational characteristics of the major components of Nuclear Steam Supply System (NSSS) and Balance of Plant (BOP); (2) Acoustic Monitoring System for detection and location of leaks in the primary system pressure boundary and other piping systems in PWRs; (3) Metal Impact Monitoring for detection of loose debris in the reactor vessel and steam generators; (4) Nuclear Noise Monitoring System for monitoring core barrel vibration; (5) Sensor Response Time Measurement System for detecting any degradation of process sensors; and (6) Transit Time Flow Meter for determining primary coolant flow rate. Summarized in this paper are some of the features of the systems and in-plant experience. These experiences demonstrate that diagnostic systems in combination with analytical and laboratory work for data interpretation do improve plant availability. (author)

  6. Diagnostic Performance of Narrow Band Imaging for Laryngeal Cancer: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Sun, Changling; Han, Xue; Li, Xiaoying; Zhang, Yayun; Du, Xiaodong

    2017-04-01

    Objective To evaluate the performance of narrow band imaging (NBI) for the diagnosis of laryngeal cancer and to compare the diagnostic value of NBI with that of white light endoscopy. Data Sources PubMed, Embase, Cochrane Library, and CNKI databases. Review Methods Data analyses were performed with Meta-DiSc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with the Deeks's asymmetry test. The protocol used in this article has been published on PROSPERO and is in accordance with the PRISMA checklist. The registry number for this study is CRD42015025866. Results Six studies including 716 lesions were included in this meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio for the NBI diagnosis of laryngeal cancer were 0.94 (95% confidence interval [95% CI]: 0.91-0.96), 0.89 (95% CI: 0.85-0.92), and 142.12 (95% CI: 46.42-435.15), respectively, and the area under receiver operating characteristics curve was 0.97. Among the 6 studies, 3 evaluated the diagnostic value of white light endoscopy, with a sensitivity of 0.81 (95% CI: 0.76-0.86), a specificity of 0.92 (95% CI: 0.88-0.95), and a diagnostic odds ratio of 33.82 (95% CI: 14.76-77.49). The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I 2 of 66%. No marked publication bias ( P = .84) was detected in this meta-analysis. Conclusion The sensitivity of NBI is superior to white light endoscopy, and the potential value of NBI needs to be validated in future studies.

  7. On-Line Monitoring of Instrument Channel Performance in Nuclear Power Plant Using PEANO

    International Nuclear Information System (INIS)

    Fantoni, Paolo F.; Hoffmann, Mario; Shankar, Ramesh; Davis, Eddie L.

    2002-01-01

    On-Line monitoring evaluates instrument channel performance by assessing its consistency with other plant indications. Industry and EPRI experience at several plants has shown this overall approach to be very effective in identifying instrument channels that are exhibiting degrading or inconsistent performance characteristics. On-Line monitoring of instrument channels provides information about the condition of the monitored channels through accurate, more frequent monitoring of each channel's performance over time. This type of performance monitoring is a methodology that offers an alternate approach to traditional time-directed calibration. On-line monitoring of these channels can provide an assessment of instrument performance and provide a basis for determining when adjustments are necessary. Elimination or reduction of unnecessary field calibrations can reduce associated labor costs, reduce personnel radiation exposure and reduce the potential for miss-calibration. PEANO is a system for on-line calibration monitoring developed in the years 1995-2000 at the Institutt for energiteknikk (IFE), Norway, which makes use of Artificial Intelligence techniques for its purpose. The system has been tested successfully in Europe in off-line tests with EDF (France), Tecnatom (Spain) and ENEA (Italy). PEANO is currently installed and used for on-line monitoring at the HBWR reactor in Halden. This paper describes the results of performance tests on PEANO with real data from a US PWR plant, in the framework of a co-operation among IFE, EPRI and Edan Engineering, to evaluate the potentials of PEANO for future installations in US nuclear plants. (authors)

  8. Monitoring the performance of off-site processors

    International Nuclear Information System (INIS)

    Miller, C.C.

    1995-01-01

    Commercial nuclear power plants have been able to utilize the latest technologies and achieve large volume reduction by obtaining off-site waste processor services. Although the use of such services reduce the burden of waste processing it also reduces the utility's control over the process. Monitoring the performance of off-site processors is important so that the utility is cognizant of the waste disposition for required regulatory reporting. In addition to obtaining data for Reg Guide 1.21 reporting, Performance monitoring is important to determine which vendor and which services to utilize. Off-site processor services were initially offered for the decontamination of metallic waste. Since that time the list of services has expanded to include supercompaction, survey for release, incineration and metal melting. The number of vendors offering off-site services has increased and the services they offer vary. processing rates vary between vendors and have different charge bases. Determining which vendor to use for what service can be complicated and confusing

  9. Diagnostic performance of CT and MRI on the detection of symptomatic intracranial dural arteriovenous fistula: a meta-analysis with indirect comparison

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yen-Heng [National Taiwan University, Institute of Epidemiology and Preventive Medicine, Taipei (China); National Taiwan University Hospital in Taipei and Yuan-Lin Branch, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); Lin, Hsien-Ho [National Taiwan University, Institute of Epidemiology and Preventive Medicine, Taipei (China); Liu, Hon-Man; Lee, Chung-Wei; Chen, Ya-Fang [National Taiwan University Hospital in Taipei and Yuan-Lin Branch, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China)

    2016-08-15

    This study aims to review the diagnostic performance of computed tomography (CT) and magnetic resonance imaging (MRI) in symptomatic dural arteriovenous fistula (DAVF). EMBASE, PubMed, and Cochrane Library were searched until April 2015 for studies which compared CT, MRI, or both with angiography for the detection of DAVF. The diagnostic performances of MRI and CT were indirectly compared using modality as a covariate in the analysis. Thirteen studies met our inclusion criteria. MRI had a sensitivity of 0.90 (95 % confidence interval (CI) = 0.83-0.94) and specificity of 0.94 (95 % CI = 0.90-0.96). CT had a sensitivity of 0.80 (95 % CI = 0.62-0.90) and specificity of 0.87 (95 % CI = 0.74-0.94). MRI showed better diagnostic performance than CT (p = 0.02). Contrast medium use and time-resolved MR angiography did not improve MRI diagnostic performance (p = 0.31 and 0.44, respectively). Both CT and MRI had good diagnostic performance. MRI was better than CT on the detection of symptomatic intracranial dural arteriovenous fistula in the indirect comparison. (orig.)

  10. Automatic acoustic and vibration monitoring system for nuclear power plants

    International Nuclear Information System (INIS)

    Tothmatyas, Istvan; Illenyi, Andras; Kiss, Jozsef; Komaromi, Tibor; Nagy, Istvan; Olchvary, Geza

    1990-01-01

    A diagnostic system for nuclear power plant monitoring is described. Acoustic and vibration diagnostics can be applied to monitor various reactor components and auxiliary equipment including primary circuit machinery, leak detection, integrity of reactor vessel, loose parts monitoring. A noise diagnostic system has been developed for the Paks Nuclear Power Plant, to supervise the vibration state of primary circuit machinery. An automatic data acquisition and processing system is described for digitalizing and analysing diagnostic signals. (R.P.) 3 figs

  11. Diagnostics for the 1.5 GeV Transport Line at the NSRRC

    CERN Document Server

    Hu, K H; Hsu, K T; Kuo, C H; Lee, D; Wang, C J; Yang, Y T

    2005-01-01

    The extracted 1.5 GeV electron beams from the booster synchrotron are transported via a transport line and injected into the storage ring. This booster-to-storage ring transport line equipped with stripline beam positions monitors, integrated current transformers, fast current transformer, and screen monitors. Commercial log-ratio BPM electronics were adopted to process the 500MHz bunch signal directly. The position of the passing beam is digitized by VME analog interface. The transmission efficiency is measured by integrated current transformer. Screen monitors are used to support routine operation. This report summary the system architecture, software tools, and performance of the BTS diagnostics.

  12. FEL components and diagnostics

    International Nuclear Information System (INIS)

    Carr, R.

    1997-01-01

    FEL hardware includes undulators, alignment systems, electron beam diagnostics, and mechanical and vacuum systems. While most FEL close-quote s employ conventional undulators, there is some interest in novel types, particularly where conventional designs cannot be used, as at very short periods and high fields. For these areas, superconducting technology is indicated. The most serious issue facing long FEL undulators is that of alignment; mechanical techniques may not be accurate enough, and beam-based strategies must be considered. To maintain alignment and control the electron trajectory, beam position monitors with micron precision are required. Beam size monitors are also required to assure control of emittance. The talks given in the working group sessions touch on undulators, alignment, and electron beam diagnostics, and they are summarized here. copyright 1997 American Institute of Physics

  13. Diagnostic value and cost-benefit analysis of 24?hours ambulatory blood pressure monitoring in primary care in Portugal

    OpenAIRE

    Pessanha, Paulo; Viana, Manuel; Ferreira, Paula; Bertoquini, Susana; Pol?nia, Jorge

    2013-01-01

    Background Hypertensive patients (HTs) are usually attended in primary care (PC). We aimed to assess the diagnostic accuracy and cost-benefit ratio of 24-hour ambulatory blood pressure monitoring (ABPM) in all newly diagnosed hypertensive patients (HTs) attended in PC. Methods In a cross-sectional study ABPM was recorded in all 336 never treated HTs (Office BP ?140 and/or???90?mm Hg) that were admitted during 16?months. Since benefits from drug treatment in white-coat hypertension (WCH) remai...

  14. Enhancing the performance of mine communication, warning and condition monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Myszkowski, M.; Rellecke, R.; Widera, K. (and others) [DMT GmbH, Essen (Germany)

    2008-07-01

    This project investigated improvements in power line communications (PLC), condition monitoring techniques and diagnostic aids, together with improving audible communication systems underground. The work on PLC investigated narrow-band, low data rate technologies and high data bandwidth broadband PLC technologies. It is concluded that broadband PLC technologies cannot currently meet the requirements of providing backbone communications in mining and that fibre-optic methods offer better performance. However, short range broadband applications are feasible and an innovative voice and data transmission system, including remote control features, has been developed for coalface communications, using radiofrequency and digital voice technologies not previously used for this application. This system accommodates all the new digital interfaces: Bluetooth, PLC, twisted pair cables, etc. The condition monitoring research has led to a suite of new specialised ATEX-certified sensors together with the development of new vibration signature tracking and classification devices and methods, which provide an early indication of incipient failure. Particular value of these methods is anticipated with coalface equipment. A further component of the work examined the practicability of implementing noise reduction techniques in mining communications systems and noisy workplaces by means of active noise cancellation (ANC). Whilst ANC-based techniques would not be currently cost-effective, several other practical communication improvements are worth considering further. These include new hearing protector technologies and a simple but effective 'waveshape compressor' to improve speech dynamic range in communication systems. A final component of the project examined the issue of mining alerts and alarms, where significant advances in signal design tools have been made. 60 refs., 138 figs., 8 tabs., 1 app.

  15. Epidemiological Concepts Regarding Disease Monitoring and Surveillance

    Directory of Open Access Journals (Sweden)

    Christensen Jette

    2001-03-01

    Full Text Available Definitions of epidemiological concepts regarding disease monitoring and surveillance can be found in textbooks on veterinary epidemiology. This paper gives a review of how the concepts: monitoring, surveillance, and disease control strategies are defined. Monitoring and surveillance systems (MO&SS involve measurements of disease occurrence, and the design of the monitoring determines which types of disease occurrence measures can be applied. However, the knowledge of the performance of diagnostic tests (sensitivity and specificity is essential to estimate the true occurrence of the disease. The terms, disease control programme (DCP or disease eradication programme (DEP, are defined, and the steps of DCP/DEP are described to illustrate that they are a process rather than a static MO&SS.

  16. An Evaluation of the Performance Diagnostic Checklist-Human Services to Assess an Employee Performance Problem in a Center-Based Autism Treatment Facility

    Science.gov (United States)

    Ditzian, Kyle; Wilder, David A.; King, Allison; Tanz, Jeanine

    2015-01-01

    The Performance Diagnostic Checklist-Human Services (PDC-HS) is an informant-based tool designed to assess the environmental variables that contribute to poor employee performance in human services settings. We administered the PDC-HS to 3 supervisors to assess the variables that contributed to poor performance by 4 staff members when securing…

  17. Standard guide to In-Plant performance evaluation of Hand-Held SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This guide is one of a series on the application and evaluation of special nuclear material (SNM) monitors. Other guides in the series are listed in Section 2, and the relationship of in-plant performance evaluation to other procedures described in the series is illustrated in Fig. 1. Hand-held SNM monitors are described in of Guide C1112, and performance criteria illustrating their capabilities can be found in Appendix X1. 1.2 The purpose of this guide to in-plant performance evaluation is to provide a comparatively rapid procedure to verify that a hand-held SNM monitor performs as expected for detecting SNM or alternative test sources or to disclose the need for repair. The procedure can be used as a routine operational evaluation or it can be used to verify performance after a monitor is calibrated. 1.3 In-plant performance evaluations are more comprehensive than daily functional tests. They take place less often, at intervals ranging from weekly to once every three months, and derive their result fr...

  18. CLASSIFICATION OF THE MGR PERFORMANCE CONFIRMATION DATA ACQUISITION/MONITORING SYSTEM

    International Nuclear Information System (INIS)

    J.A. Ziegler

    1999-01-01

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) performance confirmation data acquisition/monitoring system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMF 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333PY ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998)

  19. Status of the SLAC SNOOP diagnostic module for FASTBUS

    International Nuclear Information System (INIS)

    Walz, H.V.; Gustavson, D.B.

    1983-03-01

    A SNOOP Diagnostic Module for FASTBUS is under development at SLAC. The SNOOP Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. It consists of a high-speed ECL front-end to monitor and single-step segment operations, a simple master interface, and a control processor with two serial communication ports. Module features and specifications are summrized, and prototype hardware is shown

  20. The diagnostic performance of imaging methods in ARVC using the 2010 Task Force criteria

    DEFF Research Database (Denmark)

    Borgquist, Rasmus; Haugaa, Kristina H; Gilljam, Thomas

    2014-01-01

    , fractional area shortening 31 ± 9 vs. 39 ± 9% (P performance was low; sensitivity 50% and specificity 70%, positive predictive value 80% and negative predictive value 37...... evaluation of subtle structural changes in the right ventricle may be unreliable, and the diagnostic performance of CMR compared with echocardiography should be reflected in the guidelines....

  1. Diagnostic Performance of Ultrasonography for Pediatric Appendicitis: A Night and Day Difference?

    Science.gov (United States)

    Mangona, Kate Louise M; Guillerman, R Paul; Mangona, Victor S; Carpenter, Jennifer; Zhang, Wei; Lopez, Monica; Orth, Robert C

    2017-12-01

    For imaging pediatric appendicitis, ultrasonography (US) is preferred because of its lack of ionizing radiation, but is limited by operator dependence. This study investigates the US diagnostic performance during night shifts covered by radiology trainees compared to day shifts covered by attending radiologists. Appy-Scores (1 = completely visualized normal appendix; 2 = partially visualized normal appendix; 3 = nonvisualized appendix with no inflammatory changes in the expected region of the appendix; 4 = equivocal; 5a = nonperforated appendicitis; 5b = perforated appendicitis) from 2935 US examinations (2161:774, day-to-night) from July 2013 to 2014 were correlated with the intraoperative diagnoses and the clinical follow-up. The diagnostic performance of trainees and attendings was compared with Fisher exact test. Interobserver agreement was measured by Cohen kappa coefficient. Appendicitis prevalence was 25.3% (day) and 22.5% (night). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive vale were 94.0%, 93.7%, 93.8%, 97.9%, and 83.4% during the day and 92.0%, 91.2%, 91.3%, 97.5%, and 75.2% at night. Specificity (P = .048) and positive predictive value (P = .011) differed, with more false positives at night (7%) than during the day (4.7%). Trainee and attending agreement was high (k = 0.995), with Appy-Scores of 1, 4, and 5a most frequently discordant. US has a high diagnostic performance and interobserver agreement for pediatric appendicitis when interpreted by radiology trainees during night shifts or attending radiologists during day shifts. However, lower specificity and positive predictive value at night warrants a thorough trainee education to avoid false-positive examinations. Published by Elsevier Inc.

  2. Clay as Thermoluminescence Dosemeter in diagnostic Radiology ...

    African Journals Online (AJOL)

    This paper reports the investigation of the basic thermoluminescence properties of clay at x-rays in the diagnostic radiology range, including dose monitoring in abdominal radiography. Clay sourced from Calabar, Nigeria, was tested for thermoluminescence response after irradiation at diagnostic radiology doses, including ...

  3. Diagnostic performances of serum liver enzymes and cytokines in non-alcoholic fatty liver disease

    Directory of Open Access Journals (Sweden)

    Hakan Turkon

    2015-03-01

    Full Text Available Objective:Non-alcoholic fatty liver disease (NAFLD is affecting people worldwide with increasing prevalence. Non-invasive tests are required for both diagnosis and staging of the disease. We aimed to evaluate diagnostic accuracy of routine liver enzymes and cytokines in NAFLD. Methods:A total of 88 cases, aged between 20 and 62 years, were included in the study. Serum ALT, AST, GGT, triglyceride, TNF-alpha, IL-6 and IL-8 were measured in 40 patients with NAFLD and in 48 healthy control patients with similar BMI and demographic characteristics. Diagnostic performances of serum biomarkers for diagnosis of NAFLD were evaluated with ROC analysis. Results:ALT and AST showed good diagnostic performance in predicting patients with NAFLD in the overall group (AUC=0.817; 95% CI[0.721-0.913], AUC=0.815;95% CI[0.718-0.911] respectively but in obese subjects ALT and AST showed poor performance (AUC=0.659;95% CI[0.478-0.841], AUC=0.680; 95% CI[0.498-0.861] respectively. Among cytokines TNF-alpha showed best performance in the diagnosis of NAFLD in both overall group and obese subjects (AUC=0.892; 95% CI[0.824- 0.959], AUC=0.858; 95% CI[0.739-0.977] respectively. The optimal cut off value for TNF-alpha was 10.65pg/ml with a sensitivity of 75% and a specificity of 93% in the overall group. IL-6 and IL-8 showed poor performance. Conclusion: TNF-alpha may be a good parameter for predicting patients with NAFLD. J Clin Exp Invest 2015;6 (1: 16-20

  4. Comparative survey of site and personnel monitoring characteristics for operation of various types of diagnostic-X ray equipment

    International Nuclear Information System (INIS)

    Lyarskij, P.P.; Zol'nikova, N.I.

    1977-01-01

    Diagnostic X-ray machines in present use at medical facilities differ in design and operating parameters, this diversity producing, in turn, a variety of local radiological situations and levels of personnel exposure. Based on radiological safety characterization of working conditions, the authors present a breakdown of contemporary diagnostic X-ray equipment types, based on detailed examination of each group in terms of their associated site monitoring and dosimetry patterns. The paper reports data on personnel exposure levels not only as a function of equipment design and operating characteristics but also according to types of occupational activities for particular medical personnel groups (radiologists, surgeons, anesthesiologists, etc.). Included are health physics data for domestic and foreign X-ray equipment, levels of local and absorbed doses for radiologists, cardiovascular surgeons, neurosurgeons, urologists, traumatologists, anesthesiologists, etc. Measures are recommended for optimizing their activities from the standpoint of radiation safety. (author)

  5. Climate Prediction Center - Monitoring and Data Index

    Science.gov (United States)

    Weather Service NWS logo - Click to go to the NWS home page Climate Prediction Center Home Site Map News ; Atmospheric Monitoring and Data Monitoring Weather & Climate in Realtime Climate Diagnostics Bulletin Preliminary Climate Diagnostics Bulletin Figures Monthly Atmospheric & Sea Surface Temperature Indices

  6. Quantitative evaluation of visual detection performance in medicine: ROC analysis and determination of diagnostic benefit

    International Nuclear Information System (INIS)

    Metz, C.E.; Starr, S.J.; Lusted, L.B.

    1976-01-01

    An ROC curve provides an empirical description of the trade-offs which are possible among the various types of correct and incorrect decisions as the human decision-maker varies one or more confidence thresholds. Conventional ROC curves measured in simple decision-making situations can, in some cases, be used to predict human decision performance in more complex situations. By considering both the consequences of the various types of diagnostic decisions and the overhead cost of a diagnostic study, one can use the ROC curve to evaluate the diagnostic usefulness of a study in any particular clinical context. Since the ROC curve describes the possible relationships among the probabilities of the various types of correct and incorrect decisions, it plays a central role in optimizing diagnostic strategies using the general techniques of decision analysis. Applications in radiographic image evaluation are described

  7. Environmental performance, profitability, asset utilization, debt monitoring and firm value

    Science.gov (United States)

    Bukit, R. Br; Haryanto, B.; Ginting, P.

    2018-02-01

    The growing issue on firm value shows that firm value is not only determined by the firm ability to increase financial profit, but also by the company's concern in maintaining the environmental condition. The industrial development produces waste that pollutes the environment that has potential to serious impact on the next life. In addition to provide financial benefits, companies are increasingly facing pressure to be socially responsible for the survival of the company. However, past findings demonstrate that the effect of environmental performance, profitability, and asset utilization to the firm’s value are still unclear. This study aims to test whether environmental performance, firm profitability and asset utilization can effectively enhance firm value in two different conditions: intensive debt monitoring and less intensive debt monitoring. Sample of companies is taken from the list of Indonesia Stock Exchange during the period of 2013 to 2015. Using multiple regression analysis, discloses that: in intensive monitoring, managers tend to have high firm value when company has high environmental performance and or high profitability and high asset utilization. Monitoring system needs to be intensified especially for companies with the above characteristics.

  8. Expert system applications in support of system diagnostics and prognostics at EBR-II

    International Nuclear Information System (INIS)

    Lehto, W.K.; Gross, K.C.

    1989-01-01

    Expert systems have been developed to aid in the monitoring and diagnostics of the Experimental Breeder Reactor-II (EBR-II) at the Idaho National Engineering Laboratory (INEL) in Idaho Falls, Idaho. Systems have been developed for failed fuel surveillance and diagnostics and reactor coolant pump monitoring and diagnostics. A third project is being done jointly by ANL-W and EG ampersand G Idaho to develop a transient analysis system to enhance overall plant diagnostic and prognostic capability. The failed fuel surveillance and diagnosis system monitors, processes, and interprets information from nine key plant sensors. It displays to the reactor operator diagnostic information needed to make proper decisions regarding technical specification conformance during reactor operation with failed fuel. 8 refs., 9 figs., 2 tabs

  9. Diagnostic performance of combined single photon emission computed tomographic scintimammography and ultrasonography based on computer-aided diagnosis for breast cancer

    International Nuclear Information System (INIS)

    Hwang, Kyung Hoon; Choi, Duck Joo; Choe, Won Sick; Lee, Jun Gu; Kim, Jong Hyo; Lee, Hyung Ji; Om, Kyong Sik; Lee, Byeong Il

    2007-01-01

    We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors.) The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve=0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve=0.860), but there was no statistical difference in sensitivity, specificity and accuracy between the combined method and a single modality. It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer

  10. Reverse iontophoresis of urea in health and chronic kidney disease: a potential diagnostic and monitoring tool?

    Science.gov (United States)

    Ebah, Leonard M; Read, Ian; Sayce, Andrew; Morgan, Jane; Chaloner, Christopher; Brenchley, Paul; Mitra, Sandip

    2012-01-01

    Background Patients with chronic kidney disease (CKD) need regular monitoring, usually by blood urea and creatinine measurements, needing venepuncture, frequent attendances and a healthcare professional, with significant inconvenience. Noninvasive monitoring will potentially simplify and improve monitoring. We tested the potential of transdermal reverse iontophoresis of urea in patients with CKD and healthy controls. Methods Using a MIC 2® Iontophoresis Controller, reverse iontophoresis was applied on the forearm of five healthy subjects (controls) and 18 patients with CKD for 3–5 h. Urea extracted at the cathode was measured and compared with plasma urea. Results Reverse iontophoresis at 250 μA was entirely safe for the duration. Cathodal buffer urea linearly correlated with plasma urea after 2 h (r = 0·82, P urea (y) from cathodal urea after 2 and 3 h, respectively. Cathodal urea concentration in controls was significantly lower than in patients with CKD after a minimum current application of 2 h (P urea cut-off of 30 μM gave a sensitivity of 83·3% and positive predictive value of 87% CKD. During haemodialysis, the fall in cathodal urea was able to track that of blood urea. Conclusion Reverse iontophoresis is safe, can potentially discriminate patients with CKD and healthy subjects and is able to track blood urea changes on dialysis. Further development of the technology for routine use can lead to an exciting opportunity for its use in diagnostics and monitoring. PMID:22409780

  11. Status of ITER neutron diagnostic development

    International Nuclear Information System (INIS)

    Sasao, M.; Krasilnikov, A.V.; Kaschuck, Yu.A.; Nishitani, T.; Batistoni, P.; Zaveryaev, V.S.; Popovichev, S.; Jarvis, O.N.; Iguchi, T.; Kaellne, J.; Fiore, C.L.; Roquemore, A.L.; Heidbrink, W.W.; Fisher, R.; Gorini, G.; Donne, A.J.H.; Costley, A.E.; Walker, C.I.

    2005-01-01

    Due to the high neutron yield and the large plasma size many ITER plasma parameters such as fusion power, power density, ion temperature, fast ion energy and their spatial distributions in the plasma core can be well measured by various neutron diagnostics. Neutron diagnostic systems under consideration and development for ITER include: radial and vertical neutron cameras (RNC and VNC), internal and external neutron flux monitors, neutron activation systems and neutron spectrometers. The two-dimensional neutron source strength and spectral measurements can be provided by the combined RNC and VNC. The neutron flux monitors need to meet the ITER requirement of time-resolved measurements of the neutron source strength and can provide the signals necessary for real-time control of the ITER fusion power. Compact and high throughput neutron spectrometers are under development. A concept for the absolute calibration of neutron diagnostic systems is proposed. The development, testing in existing experiments and the engineering integration of all neutron diagnostic systems into ITER are in progress and the main results are presented. (author)

  12. New analysis and performance of a wall-current monitor

    Energy Technology Data Exchange (ETDEWEB)

    Suwada, T.; Urano, T.; Kobayashi, H. [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Tamiya, K.; Asami, A. [Naruto University of Education, Takashima, Naruto-cho, Naruto-shi 772 (Japan)

    1997-09-01

    A new wall-current monitor has been developed in order to reinforce the beam-monitoring system in the PF 2.5-GeV linac for the KEK B-Factory. A prototype monitor was tested for its performance and characteristics. The experimental results in terms of both bench tests and beam tests by single-bunch electron beams were analyzed on the basis of equivalent-circuit models. The frequency response of the monitor agreed well with a lumped equivalent-circuit model for both time- and frequency-domain measurements. The position dependence and its frequency characteristics of the monitor also agreed well with a distributed equivalent-circuit model for both time- and frequency-domain measurements. The rise time of the monitor was about 3 ns, which indicated a poor response for short-pulse beams (<1) ns. The reason could be attributed to the stray inductance of the ceramic solid resistor and not very good frequency response of the ferrite core. (orig.).

  13. New analysis and performance of a wall-current monitor

    International Nuclear Information System (INIS)

    Suwada, T.; Urano, T.; Kobayashi, H.; Tamiya, K.; Asami, A.

    1997-01-01

    A new wall-current monitor has been developed in order to reinforce the beam-monitoring system in the PF 2.5-GeV linac for the KEK B-Factory. A prototype monitor was tested for its performance and characteristics. The experimental results in terms of both bench tests and beam tests by single-bunch electron beams were analyzed on the basis of equivalent-circuit models. The frequency response of the monitor agreed well with a lumped equivalent-circuit model for both time- and frequency-domain measurements. The position dependence and its frequency characteristics of the monitor also agreed well with a distributed equivalent-circuit model for both time- and frequency-domain measurements. The rise time of the monitor was about 3 ns, which indicated a poor response for short-pulse beams (<1) ns. The reason could be attributed to the stray inductance of the ceramic solid resistor and not very good frequency response of the ferrite core. (orig.)

  14. Impact of ANSI 2009 criteria for performance testing in TLD personnel monitoring

    International Nuclear Information System (INIS)

    MeenaI, P.; Rakesh, R.B.; Srivastava, Kshama; KoIambe, D.H.; Sapra, B.K.

    2014-01-01

    External Quality Assurance in TLD Personnel Monitoring Service was initiated in 1985, for periodic performance evaluation of various TLD Laboratories through postal exercise. Presently, all the 16 laboratories involved in Personnel Monitoring Service are covered under QA exercise. Since beginning, American National Standards Institute (ANSI) criteria have been adopted for performance testing in QA exercise. Presently, ANSI 2001 performance criteria along with ISO trumpet curve analysis method are being used for performance evaluation. In 2009, ANSI modified the performance evaluation criteria and this study evaluates its impact and feasibility of implementation of ANSI 2009 criteria in the quality assurance program for personnel monitoring. The performance of some laboratories evaluated using both ANSI 2001 and ANSI 2009 criteria have been discussed. The study shows that the ANSI 2009 criteria is more stringent and encourages even distribution of bias and standard deviation. This can be implemented with suitable modifications for performance evaluation

  15. Performance monitoring pavements with thermal segregation in Texas.

    Science.gov (United States)

    2012-04-01

    This project conducted work to investigate the performance of asphalt surface mixtures that exhibited : thermal segregation during construction. From 2004 to 2009, a total of 14 construction projects were : identified for monitoring. Five of these pr...

  16. Ares I-X Ground Diagnostic Prototype

    Science.gov (United States)

    Schwabacher, Mark A.; Martin, Rodney Alexander; Waterman, Robert D.; Oostdyk, Rebecca Lynn; Ossenfort, John P.; Matthews, Bryan

    2010-01-01

    The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.

  17. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kitao, Shinichiro; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago City, Tottori (Japan); Kaetsu, Yasuhiro [Kakogawa Higashi Hospital, Department of Cardiology, Kakogawa (Japan); Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro [Tottori University, Division of Cardiology, Department of Molecular Medicine and Therapeutics, Faculty of Medicine, Yonago (Japan)

    2017-07-15

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. (orig.)

  18. Simulated performance of the optical Thomson scattering diagnostic designed for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ross, J. S., E-mail: ross36@llnl.gov; Datte, P.; Divol, L.; Galbraith, J.; Hatch, B.; Landen, O.; Manuel, A. M.; Molander, W.; Moody, J. D.; Swadling, G. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Froula, D. H.; Katz, J. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Glenzer, S. H. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Kilkenny, J. [General Atomics, San Diego, California 92186 (United States); Montgomery, D. S. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Weaver, J. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2016-11-15

    An optical Thomson scattering diagnostic has been designed for the National Ignition Facility to characterize under-dense plasmas. We report on the design of the system and the expected performance for different target configurations. The diagnostic is designed to spatially and temporally resolve the Thomson scattered light from laser driven targets. The diagnostic will collect scattered light from a 50 × 50 × 200 μm volume. The optical design allows operation with different probe laser wavelengths. A deep-UV probe beam (λ{sub 0} = 210 nm) will be used to Thomson scatter from electron plasma densities of ∼5 × 10{sup 20} cm{sup −3} while a 3ω probe will be used for plasma densities of ∼1 × 10{sup 19} cm{sup −3}. The diagnostic package contains two spectrometers: the first to resolve Thomson scattering from ion acoustic wave fluctuations and the second to resolve scattering from electron plasma wave fluctuations. Expected signal levels relative to background will be presented for typical target configurations (hohlraums and a planar foil).

  19. Beam Diagnostics for the BNL Energy Recovery Linac Test Facility

    International Nuclear Information System (INIS)

    Cameron, Peter; Ben-Zvi, Ilan; Blaskiewicz, Michael; Brennan, Michael; Connolly, Roger; Dawson, William; Degen, Chris; DellaPenna, Al; Gassner, David; Kesselman, Martin; Kewish, Jorg; Litvinenko, Vladimir; Mead, Joseph; Oerter, Brian; Russo, Tom; Vetter, Kurt; Yakimenko, Vitaly

    2004-01-01

    An Energy Recovery Linac (ERL) test facility is presently under construction at BNL. The goals of this test facility are first to demonstrate stable intense CW electron beam with parameters typical for the RHIC e-cooling project (and potentially for eRHIC), second to test novel elements of the ERL (high current CW photo-cathode, superconducting RF cavity with HOM dampers, and feedback systems), and finally to test lattice dependence of stability criteria. Planned diagnostics include position monitors, loss monitors, transverse profile monitors (both optical and wires), scrapers/halo monitors, a high resolution differential current monitor, phase monitors, an energy spread monitor, and a fast transverse monitor (for beam break-up studies and the energy feedback system). We discuss diagnostics challenges that are unique to this project, and present preliminary system specifications. In addition, we include a brief discussion of the timing system

  20. Condition monitoring and diagnostic systems integration - guiding principles and practical examples

    Energy Technology Data Exchange (ETDEWEB)

    Roverso, D.; Farbrot, J.E.; Gran, F.S.; Hoffmann, M.

    2005-08-15

    Recent years have seen a steady stream of new condition monitoring and diagnostic (CMD) systems and techniques being designed for applications in the nuclear industry. The HRP has been particularly active in this respect with the development of systems such as PEANO for on-line sensor calibration monitoring and aladdin for early fault detection and diagnosis. The availability at the HRP of a wide range of other Computerized Operations Support Systems as well as the availability of the HAMMLAB experimental control room has also allowed for the investigation of the range of issues related to the integration of such systems into control room settings. After a brief description of the development and application of these CMD systems, the report identifies three different levels of integration that should be taken into consideration. These are the data level, the operational level, and the functional level. The data level includes all aspects of data communication between the CMD system, the plant instrumentation, and the other computerized support systems present at the plant. The operational level includes all those aspects of integration that influence the way in which the operator interacts with the CMD system, with a clear emphasis on Human System Interface (HSI) integration. The functional level includes those aspects of integration that deal with the functionality of the CMD system and how this can support or be combined with the functionality offered by other support systems with the aim of exploiting synergistic effects and achieving new functions. Additionally, the report identifies a set of guiding principles of integration that can be applied at all three levels of integration. Case studies taken from experiences gathered at the HRP are used throughout the report to exemplify the identified integration principles. (Author)

  1. Tribological diagnostics as a precondition for maintenance

    International Nuclear Information System (INIS)

    Jolevski, Tome

    1999-01-01

    The concept of maintenance in one industrial system usually represents a sum of constructions and rules that point out to several facts: 1) over which technical system the maintenance should be applied, 2) when it should be applied and 3) on which way it should be organized. In our real industrial systems the contemporary maintenance of the technical systems is not enough. Also, other contemporary measures whose basic task is to prevent unplanned stoppages as well as damages in the production process are insufficient. The equipment of the technical systems with devices for permanent monitoring of the condition, in other words with devices for technical diagnostic is unsatisfactorily, with a small exemption of the devices for vibration diagnostic monitoring of the condition in real time. The tribological diagnostics, using the procedures and methods without destroying as well as measuring and monitoring the condition of the lubrication devices, allows to find out the real status of the technical systems in operation. On that basic it is possible to undertake correct maintenance measures which would provide promising and safe operation of the technical systems. (Author)

  2. Performance monitoring in obsessive-compulsive undergraduates: Effects of task difficulty.

    Science.gov (United States)

    Riesel, Anja; Richter, Anika; Kaufmann, Christian; Kathmann, Norbert; Endrass, Tanja

    2015-08-01

    Both obsessive-compulsive disorder and subclinical obsessive-compulsive (OC) symptoms seem to be associated with hyperactive error-related brain activity. The current study examined performance monitoring in subjects with subclinical OC symptoms using a new task with different levels of difficulty. Nineteen subjects with high and 18 subjects with low OC characteristics performed a random dot cinematogram (RDC) task with three levels of difficulty. The high and low OC groups did not differ in error-related negativity (ERN), correct-related negativity (CRN) and performance irrespective of task difficulty. The amplitude of the ERN decreased with increasing difficulty whereas the magnitude of CRN did not vary. ERN and CRN approached in size and topography with increasing difficulty, which suggests that errors and correct responses are processed more similarly. These results add to a growing number of studies that fail to replicate hyperactive performance monitoring in individuals with OC symptoms in task with higher difficulty or requiring learning. Together with these findings our results suggest that the relationship between OC symptoms and performance monitoring may be sensitive to type of task and task characteristics and cannot be observed in a RDC that differs from typically used tasks in difficulty and the amount of response-conflict. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. 12 CFR 621.10 - Monitoring of performance categories and other property owned.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Monitoring of performance categories and other property owned. 621.10 Section 621.10 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM ACCOUNTING AND REPORTING REQUIREMENTS Loan Performance and Valuation Assessment § 621.10 Monitoring of...

  4. Multi-method automated diagnostics of rotating machines

    Science.gov (United States)

    Kostyukov, A. V.; Boychenko, S. N.; Shchelkanov, A. V.; Burda, E. A.

    2017-08-01

    The automated machinery diagnostics and monitoring systems utilized within the petrochemical plants are an integral part of the measures taken to ensure safety and, as a consequence, the efficiency of these industrial facilities. Such systems are often limited in their functionality due to the specifics of the diagnostic techniques adopted. As the diagnostic techniques applied in each system are limited, and machinery defects can have different physical nature, it becomes necessary to combine several diagnostics and monitoring systems to control various machinery components. Such an approach is inconvenient, since it requires additional measures to bring the diagnostic results in a single view of the technical condition of production assets. In this case, we mean by a production facility a bonded complex of a process unit, a drive, a power source and lines. A failure of any of these components will cause an outage of the production asset, which is unacceptable. The purpose of the study is to test a combined use of vibration diagnostics and partial discharge techniques within the diagnostic systems of enterprises for automated control of the technical condition of rotating machinery during maintenance and at production facilities. The described solutions allow you to control the condition of mechanical and electrical components of rotating machines. It is shown that the functionality of the diagnostics systems can be expanded with minimal changes in technological chains of repair and operation of rotating machinery. Automation of such systems reduces the influence of the human factor on the quality of repair and diagnostics of the machinery.

  5. A simple, high performance Thomson scattering diagnostic for high temperature plasma research

    International Nuclear Information System (INIS)

    Hartog, D.J.D.; Cekic, M.

    1994-02-01

    This Thomson scattering diagnostic is used to measure the electron temperature and density of the plasma in the MST reversed-field pinch, a magnetic confinement fusion research device. This diagnostic system is unique for its type in that it combines high performance with simple design and low cost components. In the design of this instrument, careful attention was given to the suppression of stray laser line light with simple and effective beam dumps, viewing dumps, aperatures, and a holographic edge filter. This allows the use of a single grating monochromator for dispersion of the Thomson scattered spectrum onto the microchannel plate detector. Alignment and calibration procedures for the laser beam delivery system, the scattered light collection system, and the spectrometer and detector are described. A sample Thomson scattered spectrum illustrates typical data

  6. Fast Flux Test Facility performance monitoring management information: [Final report

    International Nuclear Information System (INIS)

    Newland, D.J.

    1987-09-01

    The purpose of this report is to provide management with performance data on key performance indicators for the month of July, 1987. This report contains the results for key performance indicators divided into two categories of ''overall'' and ''other''. The ''overall'' performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance

  7. Diagnostic monitor for carbon fiber processing

    Science.gov (United States)

    Paulauskas, Felix L.; Bigelow, Timothy S.; Meek, Thomas T.

    2002-01-01

    A method for monitoring characteristics of materials includes placing a material in an application zone, measuring a change in at least one property value of the application zone caused by placing the material in the application zone and relating changes in the property value of the application zone caused by the material to at least one characteristic of the material An apparatus for monitoring characteristics of a material includes a measuring device for measuring a property value resulting from applying a frequency signal to the application zone after placing a material in the application zone and a processor for relating changes in the property value caused by placement of the material in the application zone to at least one desired characteristic of the material. The application zone is preferably a resonant cavity.

  8. Condition monitoring a key component in the preventive maintenance

    International Nuclear Information System (INIS)

    Isar, C.

    2006-01-01

    The preventive maintenance programs are necessary to ensure that nuclear safety significant equipment will function when it is supposed to. Diesel generator, pumps, motor operated valves and air operated control valves are typically operated every three months. When you drive a car, you depend on lot of sounds, the feel of the steering wheel and gauges to determine if the car is running correctly. Similarly with operating equipment for a power plant - sounds or vibration of the equipment or the gauges and test equipment indicate a problem or degradation, actions are taken to correct the deficiency. Due to safety and economical reason diagnostic and monitoring systems are of growing interest in all complex industrial production. Diagnostic systems are requested to detect, diagnose and localize faulty operating conditions at an early stage in order to prevent severe failures and to enable predictive and condition oriented maintenance. In this context it is a need for using various on-line and off-line condition monitoring and diagnostics, non-destructive inspection techniques and surveillance. The condition monitoring technique used in nuclear power plant Cernavoda are presented in this paper. The selection of components and parameters to be monitored, monitoring and diagnostics techniques used are incorporated into a preventive maintenance program. Modern measurement technique in combination with advanced computerized data processing and acquisition show new ways in the field of machine surveillance. The diagnostic capabilities of predictive maintenance technologies have increased recently year with advances made in sensor technologies. The paper will focus on the following condition monitoring technique: - oil analysis - acoustic leakage monitoring - thermography - valve diagnostics: motor operated valve, air operated valve and check valve - motor current signature - vibration monitoring and rotating machine monitoring and diagnostics For each condition monitoring

  9. Vibration-based monitoring and diagnostics using compressive sensing

    Science.gov (United States)

    Ganesan, Vaahini; Das, Tuhin; Rahnavard, Nazanin; Kauffman, Jeffrey L.

    2017-04-01

    Vibration data from mechanical systems carry important information that is useful for characterization and diagnosis. Standard approaches rely on continually streaming data at a fixed sampling frequency. For applications involving continuous monitoring, such as Structural Health Monitoring (SHM), such approaches result in high volume data and rely on sensors being powered for prolonged durations. Furthermore, for spatial resolution, structures are instrumented with a large array of sensors. This paper shows that both volume of data and number of sensors can be reduced significantly by applying Compressive Sensing (CS) in vibration monitoring applications. The reduction is achieved by using random sampling and capitalizing on the sparsity of vibration signals in the frequency domain. Preliminary experimental results validating CS-based frequency recovery are also provided. By exploiting the sparsity of mode shapes, CS can also enable efficient spatial reconstruction using fewer spatially distributed sensors. CS can thereby reduce the cost and power requirement of sensing as well as streamline data storage and processing in monitoring applications. In well-instrumented structures, CS can enable continued monitoring in case of sensor or computational failures.

  10. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ju Hun [Kaya University, Gimhae (Korea, Republic of); Im, In Chul [Gwangju Health College University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Chosun University, Gwangju (Korea, Republic of); Kang, Se Sik [College of Health Science, Catholic University of Pusan, Busan (Korea, Republic of)

    2009-03-15

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  11. A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size

    International Nuclear Information System (INIS)

    Park, Ju Hun; Im, In Chul; Dong, Kyung Rae; Kang, Se Sik

    2009-01-01

    The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly

  12. Multi-complexity ensemble measures for gait time series analysis: application to diagnostics, monitoring and biometrics.

    Science.gov (United States)

    Gavrishchaka, Valeriy; Senyukova, Olga; Davis, Kristina

    2015-01-01

    Previously, we have proposed to use complementary complexity measures discovered by boosting-like ensemble learning for the enhancement of quantitative indicators dealing with necessarily short physiological time series. We have confirmed robustness of such multi-complexity measures for heart rate variability analysis with the emphasis on detection of emerging and intermittent cardiac abnormalities. Recently, we presented preliminary results suggesting that such ensemble-based approach could be also effective in discovering universal meta-indicators for early detection and convenient monitoring of neurological abnormalities using gait time series. Here, we argue and demonstrate that these multi-complexity ensemble measures for gait time series analysis could have significantly wider application scope ranging from diagnostics and early detection of physiological regime change to gait-based biometrics applications.

  13. Ruling Out Pulmonary Embolism in Primary Care: Comparison of the Diagnostic Performance of "Gestalt" and the Wells Rule

    NARCIS (Netherlands)

    Hendriksen, Janneke M. T.; Lucassen, Wim A. M.; Erkens, Petra M. G.; Stoffers, Henri E. J. H.; van Weert, Henk C. P. M.; Büller, Harry R.; Hoes, Arno W.; Moons, Karel G. M.; Geersing, Geert-Jan

    2016-01-01

    Diagnostic prediction models such as the Wells rule can be used for safely ruling out pulmonary embolism (PE) when it is suspected. A physician's own probability estimate ("gestalt"), however, is commonly used instead. We evaluated the diagnostic performance of both approaches in primary care.

  14. Characterization of the Goubau line for testing beam diagnostic instruments

    Science.gov (United States)

    Kim, S. Y.; Stulle, F.; Sung, C. K.; Yoo, K. H.; Seok, J.; Moon, K. J.; Choi, C. U.; Chung, Y.; Kim, G.; Woo, H. J.; Kwon, J.; Lee, I. G.; Choi, E. M.; Chung, M.

    2017-12-01

    One of the main characteristics of the Goubau line is that it supports a low-loss, non-radiated surface wave guided by a dielectric-coated metal wire. The dominant mode of the surface wave along the Goubau line is a TM01 mode, which resembles the pattern of the electromagnetic fields induced in the metallic beam pipe when the charged particle beam passes through it. Therefore, the Goubau line can be used for the preliminary bench test and performance optimization of the beam diagnostic instruments without requiring charged particle beams from the accelerators. In this paper, we discuss the basic properties of the Goubau line for testing beam diagnostic instruments and present the initial test results for button-type beam position monitors (BPMs). The experimental results are consistent with the theoretical estimations, which indicates that Goubau line allows effective testing of beam diagnostic equipment.

  15. Fast beam condition monitor for CMS. Performance and upgrade

    International Nuclear Information System (INIS)

    Leonard, Jessica L.; Bell, Alan; Burtowy, Piotr

    2014-05-01

    The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown.

  16. Fast Beam Condition Monitor for CMS: performance and upgrade

    CERN Document Server

    INSPIRE-00009152; Bell, Alan; Burtowy, Piotr; Dabrowski, Anne; Hempel, Maria; Henschel, Hans; Lange, Wolfgang; Lohmann, Wolfgang; Odell, Nathaniel; Penno, Marek; Pollack, Brian; Przyborowski, Dominik; Ryjov, Vladimir; Stickland, David; Walsh, Roberval; Warzycha, Weronika; Zagozdzinska, Agnieszka

    2014-11-21

    The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown.

  17. Quality assurance in CT: implementation of the updated national diagnostic reference levels using an automated CT dose monitoring system.

    Science.gov (United States)

    Appel, E; Kröpil, P; Bethge, O T; Aissa, J; Thomas, C; Antoch, G; Boos, J

    2018-03-20

    To evaluate the implementation of the updated computed tomography (CT) diagnostic reference levels (DRLs) from the German Federal Office for Radiation Protection into clinical routine using an automatic CT dose monitoring system. CT radiation exposure was analysed before and after implementing the updated national DRLs into routine clinical work in 2016. After the implementation process, institutional CT protocols were mapped to the anatomical regions for which DRLs were provided. Systematically, protocols that exceeded the thresholds were optimised and analysed in detail. The CT radiation output parameters analysed were volumetric CT dose index (CTDIvol) and dose-length product (DLP). Three radiologists evaluated subjective image quality using a three-point Likert scale. The study included 94,258 CT series (from 27,103 CT examinations) in adult patients performed in 2016. When averaged over all body regions with available DRL, institutional CTDIvol/DLP values were always below the DRLs (65.2±32.9%/67.3±41.5% initially; 59.4±32%/60.5±39.9% after optimisation). Values exceeding the national DRLs were found for pelvis (n=268; CTDIvol 107.7±65.7%/DLP 106.3±79.3%), lumbar spine (n=91; 160.8±74.7%/175.2±104.1%), and facial bones (n=527; 108±39%/152.7±75.7%). After optimisation, CTDIvol and DLP were 87.9±73%/87.8±80.8% for the pelvis, 67.8±33.2%/74.5±50.6% for the lumbar spine and 95.1±45.8%/133.3±74.6% for the viscerocranium. An automatic CT dose monitoring system enabled not only comprehensive monitoring of a DRL implementation process but can also help to optimise radiation exposure. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

    Directory of Open Access Journals (Sweden)

    Linda C. Rogers

    2016-01-01

    Full Text Available Objective Accurate and timely diagnosis of rupture of membranes (ROM is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. Methods Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus® in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and accuracy. Results Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%, specificity (94.8% vs. 79.3%, PPV (75% vs. 36.8%, NPV (100% vs. 95.8%, and accuracy (95.5% vs. 79.1%. Conclusions The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.

  19. Diagnostic Performance of Mammographic Texture Analysis in the Differential Diagnosis of Benign and Malignant Breast Tumors.

    Science.gov (United States)

    Li, Zhiming; Yu, Lan; Wang, Xin; Yu, Haiyang; Gao, Yuanxiang; Ren, Yande; Wang, Gang; Zhou, Xiaoming

    2017-11-09

    The purpose of this study was to investigate the diagnostic performance of mammographic texture analysis in the differential diagnosis of benign and malignant breast tumors. Digital mammography images were obtained from the Picture Archiving and Communication System at our institute. Texture features of mammographic images were calculated. Mann-Whitney U test was used to identify differences between the benign and malignant group. The receiver operating characteristic (ROC) curve analysis was used to assess the diagnostic performance of texture features. Significant differences of texture features of histogram, gray-level co-occurrence matrix (GLCM) and run length matrix (RLM) were found between the benign and malignant breast group (P  .05). The AUROCs of imaging-based diagnosis, texture analysis, and imaging-based diagnosis combined with texture analysis were 0.873, 0.863, and 0.961, respectively. When imaging-based diagnosis was combined with texture analysis, the AUROC was higher than that of imaging-based diagnosis or texture analysis (P benign and malignant breast tumors. Furthermore, the combination of imaging-based diagnosis and texture analysis can significantly improve diagnostic performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Soft x-ray power diagnostic improvements at the Omega Laser Facility

    International Nuclear Information System (INIS)

    Sorce, C.; Schein, J.; Weber, F.; Widmann, K.; Campbell, K.; Dewald, E.; Turner, R.; Landen, O.; Jacoby, K.; Torres, P.; Pellinen, D.

    2006-01-01

    Soft x-ray power diagnostics are essential for evaluating high temperature laser plasma experiments. The Dante soft x-ray spectrometer, a core diagnostic for radiation flux and temperature measurements of Hohlraums, installed on the Omega Laser Facility at the Laboratory for Laser Energetics has recently undergone a series of upgrades. Work performed at Brookhaven National Laboratory for the development of the National Ignition Facility (NIF) Dante spectrometer enables the Omega Dante to offer a total of 18 absolutely calibrated channels in the energy range from 50 eV to 20 keV. This feature provides Dante with the capability to measure higher, NIF relevant, radiation temperatures with increased accuracy including a differentiation of higher energy radiation such as the Au M and L bands. Diagnostic monitoring using experimental data from directly driven Au spherical shots is discussed

  1. Machine and plasma diagnostic instrumentation systems for the Tandem Mirror Experiment Upgrade

    International Nuclear Information System (INIS)

    Coutts, G.W.; Coffield, F.E.; Lang, D.D.; Hornady, R.S.

    1981-01-01

    To evaluate performance of a second generation Tandem Mirror Machine, an extensive instrumentation system is being designed and installed as part of the major device fabrication. The systems listed will be operational during the start-up phase of the TMX Upgrade machine and provide bench marks for future performance data. In addition to plasma diagnostic instrumentation, machine parameter monitoring systems will be installed prior to machine operation. Simultaneous recording of machine parameters will permit evaluation of plasma parameters sensitive to machine conditions

  2. ADAM®/SIPLUG®: An innovative valve monitoring system

    International Nuclear Information System (INIS)

    Muñoz, L.; Krell, M.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions, e.g. valve diagnostics can support this in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. The new SIPLUG®-4 modules are the evolutionary solution for valve diagnosis at the Motor Control Center (MCC). As the SIPLUG®-4 can be installed directly in the MCC outgoing actuator power cable it allows an easy installation in existing switchgear cabinets. Measurement at MCC means also zero effort for performance of diagnostics reducing the number of on-site activities. This results in decrease of maintenance costs and dose rates for deployed personnel. The ADAM® evaluation software and database was developed in parallel with the hardware. It provides automatic analysis of the monitoring results using the limit values specified for the valves. The measured data can be transmitted via the power plant’s local area network to the ADAM® data server, if the SIPLUG® online hardware is installed. With the mobile solution, the data can be transmitted via serial or USB interface to a PC or notebook. With this solution all measurement information will be available immediately in the offices of plant engineers. Also, with SIPLUG® online all operations of valves can be automatically recorded. More than 25 years of experience in various plants worldwide show that the application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. Some of the references for ADAM®/SIPLUG® are Germany, Switzerland, Brazil, Spain and Eastern Europe. (author)

  3. Electron beam diagnostics study

    International Nuclear Information System (INIS)

    Garganne, P.

    1989-08-01

    This paper summarizes the results of a study on beam diagnostics, using carbon wire scanners and optical transition radiation (DTR) monitors. The main consideration consists in the material selection, taking their thermal properties and their effect on the beam into account [fr

  4. Performance of the upgraded NSLS beam position monitors

    International Nuclear Information System (INIS)

    Nawrocky, R.J.; Keane, J.

    1997-01-01

    The design and initial performance of the original NSLS beam position monitor were described by J. Bittner and R. Biscardi in 1989. The receiver, which processes signals from four button type pick-up electrodes by time-division multiplexing, operates at the third harmonic of the ring rf frequency (158.66 MHz). It has an output bandwidth of about 2 kHz and a dynamic signal range of approximately 36 dB. A total of 92 receivers have been installed in the NSLS X-ray and VUV storage rings for orbit monitoring and for real time feedback. As part of a continuous effort to improve the NSLS storage ring performance, the BPMs as well as other instrumentation systems have also been undergoing upgrades over the past two years to improve their performance. In the BPM, the front end has been modified to prevent saturation of the rf multiplexing switch, the detector operating point was changed to improve output signal linearity, the dynamic range was increased to over 60 dB, and the gain calibration was standardized to 0.5 volts/mm (i.e. 2 microm/mV). This paper describes the BPM modifications and presents some performance data and measurements on stored beam

  5. Monitoring of vibrating machinery using artificial neural networks

    International Nuclear Information System (INIS)

    Alguindigue, I.E.; Loskiewicz-Buczak, A.

    1991-01-01

    The primary source of vibration in complex engineering systems is rotating machinery. Vibration signatures collected from these components render valuable information about the operational state of the system and may be used to perform diagnostics. For example, the low frequency domain contains information about unbalance, misalignment, instability in journal bearing and mechanical looseness; analysis of the medium frequency range can render information about faults in meshing gear teeth; while the high frequency domain will contain information about incipient faults in rolling-element bearings. Trend analysis may be performed by comparing the vibration spectrum for each machine with a reference spectrum and evaluating the vibration magnitude changes at different frequencies. This form of analysis for diagnostics is often performed by maintenance personnel monitoring and recording transducer signals and analyzing the signals to identify the operating condition of the machine. With the advent of portable fast Fourier transform (FFT) analyzers and ''laptop'' computers, it is possible to collect and analyze vibration data an site and detect incipient failures several weeks or months before repair is necessary. It is often possible to estimate the remaining life of certain systems once a fault has been detected. RMS velocity, acceleration, displacements, peak value, and crest factor readings can be collected from vibration sensors. To exploit all the information embedded in these signals, a robust and advanced analysis technique is required. Our goal is to design a diagnostic system using neural network technology, a system such as this would automate the interpretation of vibration data coming from plant-wide machinery and permit efficient on-line monitoring of these components

  6. Pressurized water reactor monitoring. Study of detection, diagnostic and estimation methods (least error squares and filtering)

    International Nuclear Information System (INIS)

    Gillet, M.

    1986-07-01

    This thesis presents a study for the surveillance of the ''primary coolant circuit inventory monitoring'' of a pressurized water reactor. A reference model is developed in view of an automatic system ensuring detection and diagnostic in real time. The methods used for the present application are statistical tests and a method related to pattern recognition. The estimation of failures detected, difficult owing to the non-linearity of the problem, is treated by the least error squares method of the predictor or corrector type, and by filtering. It is in this frame that a new optimized method with superlinear convergence is developed, and that a segmented linearization of the model is introduced, in view of a multiple filtering [fr

  7. DEVELOPMENT OF SIGNAL PROCESSING TOOLS AND HARDWARE FOR PIEZOELECTRIC SENSOR DIAGNOSTIC PROCESSES

    Energy Technology Data Exchange (ETDEWEB)

    OVERLY, TIMOTHY G. [Los Alamos National Laboratory; PARK, GYUHAE [Los Alamos National Laboratory; FARRAR, CHARLES R. [Los Alamos National Laboratory

    2007-02-09

    This paper presents a piezoelectric sensor diagnostic and validation procedure that performs in -situ monitoring of the operational status of piezoelectric (PZT) sensor/actuator arrays used in structural health monitoring (SHM) applications. The validation of the proper function of a sensor/actuator array during operation, is a critical component to a complete and robust SHM system, especially with the large number of active sensors typically involved. The method of this technique used to obtain the health of the PZT transducers is to track their capacitive value, this value manifests in the imaginary part of measured electrical admittance. Degradation of the mechanical/electric properties of a PZT sensor/actuator as well as bonding defects between a PZT patch and a host structure can be identified with the proposed procedure. However, it was found that temperature variations and changes in sensor boundary conditions manifest themselves in similar ways in the measured electrical admittances. Therefore, they examined the effects of temperature variation and sensor boundary conditions on the sensor diagnostic process. The objective of this study is to quantify and classify several key characteristics of temperature change and to develop efficient signal processing techniques to account for those variations in the sensor diagnostis process. In addition, they developed hardware capable of making the necessary measurements to perform the sensor diagnostics and to make impedance-based SHM measurements. The paper concludes with experimental results to demonstrate the effectiveness of the proposed technique.

  8. Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.

    Science.gov (United States)

    Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M

    2016-12-01

    Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.

  9. Performance of an rf beam monitor on the NBS-Los Alamos racetrack microtron

    International Nuclear Information System (INIS)

    Young, L.M.; Cutler, R.I.

    1985-01-01

    A prototype rf beam-position, current, and phase monitor has been used on the 100-keV injector beamline of the racetrack microtron (RTM) where performance was measured with the chopped and bunched beam. This monitor works with both a pulsed beam and a cw beam. The pulsed beam consists of beam pulses with a FWHM of 40 ns. The rf beam monitor was tested with beam currents from approx. 50 to 600 μA. The rf beam monitor will be described and its performance will be reported. 6 refs., 5 figs

  10. DIVA and DIAPO: two diagnostic knowledge based systems used for French nuclear power plants

    International Nuclear Information System (INIS)

    Porcheron, M.; Ricard, B.; Joussellin, A.

    1997-01-01

    In order to improve monitoring and diagnosis capabilities in nuclear power plants, Electricite de France (EDF) has designed an integrated monitoring and diagnosis assistance system: PSAD-Poste de Surveillance et d'Aide au Diagnostic. The development of such a sophisticated monitoring and data processing systems has emphasized the need for the addition of analysis and diagnosis assistance capabilities. Therefore, diagnostic knowledge based systems have been added to the functions monitored in PSAD: DIVA for turbine generators, and DIAPO for reactor coolant pumps. These systems were designed from a representation of the diagnostic reasoning process of experts and of the supporting knowledge. Diagnosis in both systems relies on an abduction reasoning process applied to component fault models and observations derived from their actual behavior, as provided by the monitoring functions. The basic theoretical elements of this diagnostic model are summarized in a first part. In a second part, DIVA and DIAPO specific elements are described

  11. A Mountain-Scale Monitoring Network for Yucca Mountain Performance Confirmation

    International Nuclear Information System (INIS)

    Freifeld, Barry; Tsang, Yvonne

    2006-01-01

    Confirmation of the performance of Yucca Mountain is required by 10 CFR Part 63.131 to indicate, where practicable, that the natural system acts as a barrier, as intended. Hence, performance confirmation monitoring and testing would provide data for continued assessment during the pre-closure period. In general, to carry out testing at a relevant scale is always important, and in the case of performance confirmation, it is particularly important to be able to test at the scale of the repository. We view the large perturbation caused by construction of the repository at Yucca Mountain as a unique opportunity to study the large-scale behavior of the natural barrier system. Repository construction would necessarily introduce traced fluids and result in the creation of leachates. A program to monitor traced fluids and construction leachates permits evaluation of transport through the unsaturated zone and potentially downgradient through the saturated zone. A robust sampling and monitoring network for continuous measurement of important parameters, and for periodic collection of agrochemical samples, is proposed to observe thermo-hydrogeochemical changes near the repository horizon and down to the water table. The sampling and monitoring network can be used to provide data to (1) assess subsurface conditions encountered and changes in those conditions during construction and waste emplacement operations; and (2) for modeling to determine that the natural system is functioning as intended

  12. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  13. Oracle as a tool for monitoring data management in French nuclear power plants

    International Nuclear Information System (INIS)

    Joussellin, A.; Tarteret, P.; Gal, A.

    1996-05-01

    On-line monitoring of the main components of the French nuclear power plants is performed using an integrated system called PSAD (Poste de Surveillance et d'Aide au Diagnostic). In real-time, physical measurement data are continuously acquired, computed and stored in an ORACLE database. All measurement data are dated and represent a wide range of physical variables (temperatures, vibrations, acoustic waves,...). Then, millions of measurements are available to the operator for diagnostic. (author)

  14. Oracle as a tool for monitoring data management in French nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Joussellin, A.; Tarteret, P.; Gal, A.

    1996-05-01

    On-line monitoring of the main components of the French nuclear power plants is performed using an integrated system called PSAD (Poste de Surveillance et d`Aide au Diagnostic). In real-time, physical measurement data are continuously acquired, computed and stored in an ORACLE database. All measurement data are dated and represent a wide range of physical variables (temperatures, vibrations, acoustic waves,...). Then, millions of measurements are available to the operator for diagnostic. (author).

  15. Diagnostic Performance of Bronchoalveolar Lavage Fluid CD4/CD8 Ratio for Sarcoidosis: A Meta-analysis.

    Science.gov (United States)

    Shen, Yongchun; Pang, Caishuang; Wu, Yanqiu; Li, Diandian; Wan, Chun; Liao, Zenglin; Yang, Ting; Chen, Lei; Wen, Fuqiang

    2016-06-01

    The usefulness of bronchoalveolar lavage fluid (BALF) CD4/CD8 ratio for diagnosing sarcoidosis has been reported in many studies with variable results. Therefore, we performed a meta-analysis to estimate the overall diagnostic accuracy of BALF CD4/CD8 ratio based on the bulk of published evidence. Studies published prior to June 2015 and indexed in PubMed, OVID, Web of Science, Scopus and other databases were evaluated for inclusion. Data on sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were pooled from included studies. Summary receiver operating characteristic (SROC) curves were used to summarize overall test performance. Deeks's funnel plot was used to detect publication bias. Sixteen publications with 1885 subjects met our inclusion criteria and were included in this meta-analysis. Summary estimates of the diagnostic performance of the BALF CD4/CD8 ratio were as follows: sensitivity, 0.70 (95%CI 0.64-0.75); specificity, 0.83 (95%CI 0.78-0.86); PLR, 4.04 (95%CI 3.13-5.20); NLR, 0.36 (95%CI 0.30-0.44); and DOR, 11.17 (95%CI 7.31-17.07). The area under the SROC curve was 0.84 (95%CI 0.81-0.87). There was no evidence of publication bias. Measuring the BALF CD4/CD8 ratio may assist in the diagnosis of sarcoidosis when interpreted in parallel with other diagnostic factors. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Implementation of the quality control of diagnostic monitors

    International Nuclear Information System (INIS)

    Ramos Pacho, J. A.; Gomez Llorente, P. L.; Gomez Llorente, N.; Cons Perez, N.; Verde Velasco, J. M.; Perez Alvarez, M. E.; Delgado Aparicio, J. M.; Garcia Repiso, S.; Montes Fuentes, C.; Martin Rincon, C.

    2013-01-01

    The optimization of the quality of Radiology is aimed at obtaining greater diagnostic information minimizing the risks to the patient. This is essential, among other factors, not only that the image acquisition system works properly, but that the display device is capable of representing the information contained. (Author)

  17. Diagnostic performance of shear wave elastography of the breast according to scanning orientation.

    Science.gov (United States)

    Kim, Solip; Choi, SeonHyeong; Choi, Yoonjung; Kook, Shin-Ho; Park, Hee Jin; Chung, Eun Chul

    2014-10-01

    To evaluate the influence of the scanning orientation on diagnostic performance measured by the mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio on ultrasound-based shear wave elastography in differentiating breast cancers from benign lesions. In this study, a total of 260 breast masses from 235 consecutive patients were observed from March 2012 to November 2012. For each lesion, the mean elasticity value, maximum elasticity value, and fat-to-lesion ratio were measured along two orthogonal directions, and all values were compared with pathologic results. There were 59 malignant and 201 benign lesions. Malignant masses showed higher mean elasticity, maximum elasticity, and fat-to-lesion ratio values than benign lesions (P masses; and mean elasticity, 0.392, for anterior mammary fat. Mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio values were helpful in differentiating benign and malignant breast masses. The scanning orientation did not significantly affect the diagnostic performance of shear wave elastography for breast masses. © 2014 by the American Institute of Ultrasound in Medicine.

  18. In-flight spectral performance monitoring of the Airborne Prism Experiment

    NARCIS (Netherlands)

    Odorico, D' P.; Alberti, E.; Schaepman, M.E.

    2010-01-01

    Spectral performance of an airborne dispersive pushbroom imaging spectrometer cannot be assumed to be stable over a whole flight season given the environmental stresses present during flight. Spectral performance monitoring during flight is commonly accomplished by looking at selected absorption

  19. One-year dynamic monitoring of a masonry tower

    Directory of Open Access Journals (Sweden)

    Guidobaldi Marco

    2015-01-01

    Full Text Available The paper presents some results of the continuous dynamic monitoring program carried out on the tallest historic tower in Mantua, Italy. This project follows an extensive diagnostic investigation aimed at assessing the structural condition of the tower after the Italian earthquakes of May 2012. A simple dynamic monitoring system was permanently installed in the upper part of the building and automatic modal identification was performed. The results allow to evaluate the effects of changing temperature on automatically identified natural frequencies, to verify the practical feasibility of damage detection methods based on natural frequencies shifts and provide clear evidence of the possible key role of continuous dynamic monitoring in the preventive conservation of historic towers.

  20. Extending role by Japanese pharmacists after training for performing vital signs monitoring

    Directory of Open Access Journals (Sweden)

    Hasegawa F

    2014-09-01

    Full Text Available Background: In Japan, the circumstances in which pharmacists work are changing. Pharmacists are expected to assess conditions of patients subject to medication to ensure proper use of pharmaceutical products. To ensure fulfilment of these roles, there have already been pharmacists’ efforts in performing vital signs monitoring. Objective: To clarify the necessity and related issues, by investigating the state of vital sign monitoring in clinical field by pharmacists who have been trained in vital sign monitoring. Method: A web survey was conducted from 4th October to 3rd December 2012, subjecting 1,026 pharmacists who completed the vital signs training hosted by The Japanese Association of Home Care Pharmacies (JAHCP. Survey items were 1 basic information of a respondent, 2 situation of homecare conducted by pharmacists, 3 seminar attendance status, and 4 vital signs monitoring status after the seminar. Results: The number of valid respondents was 430 and the response rate was 41.9%. As a result of the present research, it was revealed that 168 pharmacists (41.4%, had the opportunity to perform vital signs monitoring. By conducting vital sign monitoring, effects such as 1 improved motivation of pharmacists and better communication with patients, 2 proper use of medication, and 3 cost reduction were confirmed. Conclusion: Judging from the results of the survey, pharmacists can improve medication therapy for patients by attaining vital sign skills and conduct vital sign monitoring. Pharmacists who perform vital sign monitoring should share cases where they experienced positive patient outcomes.

  1. Evaluating the Performance Diagnostic Checklist-Human Services to Assess Incorrect Error-Correction Procedures by Preschool Paraprofessionals

    Science.gov (United States)

    Bowe, Melissa; Sellers, Tyra P.

    2018-01-01

    The Performance Diagnostic Checklist-Human Services (PDC-HS) has been used to assess variables contributing to undesirable staff performance. In this study, three preschool teachers completed the PDC-HS to identify the factors contributing to four paraprofessionals' inaccurate implementation of error-correction procedures during discrete trial…

  2. Monitoring User-System Performance in Interactive Retrieval Tasks

    NARCIS (Netherlands)

    Boldareva, L.; de Vries, A.P.; Hiemstra, Djoerd

    Monitoring user-system performance in interactive search is a challenging task. Traditional measures of retrieval evaluation, based on recall and precision, are not of any use in real time, for they require a priori knowledge of relevant documents. This paper shows how a Shannon entropy-based

  3. Does the Use of Diagnostic Technology Reduce Fetal Mortality?

    Science.gov (United States)

    Grytten, Jostein; Skau, Irene; Sørensen, Rune; Eskild, Anne

    2018-01-19

    To examine the effect that the introduction of new diagnostic technology in obstetric care has had on fetal death. The Medical Birth Registry of Norway provided detailed medical information for approximately 1.2 million deliveries from 1967 to 1995. Information about diagnostic technology was collected directly from the maternity units, using a questionnaire. The data were analyzed using a hospital fixed-effects regression with fetal mortality as the outcome measure. The key independent variables were the introduction of ultrasound and electronic fetal monitoring at each maternity ward. Hospital-specific trends and risk factors of the mother were included as control variables. The richness of the data allowed us to perform several robustness tests. The introduction of ultrasound caused a significant drop in fetal mortality rate, while the introduction of electronic fetal monitoring had no effect on the rate. In the population as a whole, ultrasound contributed to a reduction in fetal deaths of nearly 20 percent. For post-term deliveries, the reduction was well over 50 percent. The introduction of ultrasound made a major contribution to the decline in fetal mortality at the end of the last century. © Health Research and Educational Trust.

  4. TECHNICAL DIAGNOSTICS AT RUP “BMZ”

    Directory of Open Access Journals (Sweden)

    A. A. Kuzembajev

    2004-01-01

    Full Text Available The review of technical diagnostics and crack detection at RUP “BMZ” is given in the article and there are reflected the functions and tasks of the Laboratory of Technical Diagnostics and Crack detection (LTDandC. The examples of determination of the equipment failure by methods of vibration diagnostics, applied in LTDandC, are given and the efficiency of using of the system of technical servicing of the equipment according to “state” is shown. The idea of transfer from the repairs system “according to schedule” to repairs “according to state” using new information technologies such as vibrating monitoring and vibrating diagnostics is briefly reflected in the article.

  5. Studies on WWER core diagnostics

    International Nuclear Information System (INIS)

    Lunin, G.L.; Mitin, V.I.; Bulavin, V.V.

    1987-01-01

    The reliability and safety of nuclear power plants have decisive meaning under the situation that nuclear power generation steadily increases, and among various measures aiming at ensuring the reliability and safety in the operation of nuclear power plants, the countermeasures for protecting reactor core, main process equipment and high pressure circuits from damage have the important role, and the monitoring of condition and the organization of forecast, which are carried out continuously or periodically during the operation of nuclear power stations using the diagnostic expert system specially developed for the purpose, are included in them. Such monitoring enables the early detection of mechanical damage, increase of vibration, defects caused during operation and so on in reactor cores and primary and secondary circuits, and the continuous watching of defect developments. Also boiling in a core is detected, the place of abnormality occurrence is identified, and the intensity and characteristics of boiling are determined, thus the occurrence of dangerous condition is prevented. The developments of an in-core monitoring system and noise diagnostic systems are reported. (Kako, I.)

  6. Diagnostic performance of BMI percentiles to identify adolescents with metabolic syndrome.

    Science.gov (United States)

    Laurson, Kelly R; Welk, Gregory J; Eisenmann, Joey C

    2014-02-01

    To compare the diagnostic performance of the Centers for Disease Control and Prevention (CDC) and FITNESSGRAM (FGram) BMI standards for quantifying metabolic risk in youth. Adolescents in the NHANES (n = 3385) were measured for anthropometric variables and metabolic risk factors. BMI percentiles were calculated, and youth were categorized by weight status (using CDC and FGram thresholds). Participants were also categorized by presence or absence of metabolic syndrome. The CDC and FGram standards were compared by prevalence of metabolic abnormalities, various diagnostic criteria, and odds of metabolic syndrome. Receiver operating characteristic curves were also created to identify optimal BMI percentiles to detect metabolic syndrome. The prevalence of metabolic syndrome in obese youth was 19% to 35%, compared with <2% in the normal-weight groups. The odds of metabolic syndrome for obese boys and girls were 46 to 67 and 19 to 22 times greater, respectively, than for normal-weight youth. The receiver operating characteristic analyses identified optimal thresholds similar to the CDC standards for boys and the FGram standards for girls. Overall, BMI thresholds were more strongly associated with metabolic syndrome in boys than in girls. Both the CDC and FGram standards are predictive of metabolic syndrome. The diagnostic utility of the CDC thresholds outperformed the FGram values for boys, whereas FGram standards were slightly better thresholds for girls. The use of a common set of thresholds for school and clinical applications would provide advantages for public health and clinical research and practice.

  7. Optimization of Classification Strategies of Acetowhite Temporal Patterns towards Improving Diagnostic Performance of Colposcopy

    Directory of Open Access Journals (Sweden)

    Karina Gutiérrez-Fragoso

    2017-01-01

    Full Text Available Efforts have been being made to improve the diagnostic performance of colposcopy, trying to help better diagnose cervical cancer, particularly in developing countries. However, improvements in a number of areas are still necessary, such as the time it takes to process the full digital image of the cervix, the performance of the computing systems used to identify different kinds of tissues, and biopsy sampling. In this paper, we explore three different, well-known automatic classification methods (k-Nearest Neighbors, Naïve Bayes, and C4.5, in addition to different data models that take full advantage of this information and improve the diagnostic performance of colposcopy based on acetowhite temporal patterns. Based on the ROC and PRC area scores, the k-Nearest Neighbors and discrete PLA representation performed better than other methods. The values of sensitivity, specificity, and accuracy reached using this method were 60% (95% CI 50–70, 79% (95% CI 71–86, and 70% (95% CI 60–80, respectively. The acetowhitening phenomenon is not exclusive to high-grade lesions, and we have found acetowhite temporal patterns of epithelial changes that are not precancerous lesions but that are similar to positive ones. These findings need to be considered when developing more robust computing systems in the future.

  8. Diagnostic technology of PWR plant equipment failures

    International Nuclear Information System (INIS)

    Nakamura, Tetsuo; Tanaka, Mamoru; Okamachi, Masao; Taguchi, Shozo; Nagashima, Kazuhiro; Ishikawa, Satoshi

    1985-01-01

    To confirm the soundness of the important facilities in a nuclear power plant contributes to the reliability of the plant operations and improvement of its operation rate. For this purpose, the following diagnostic techniques have been developed. (1). Vibration and loose parts monitoring: Detection of abnormal structural vibrations in the reactor, estimation of its mode, detection of loose parts in the primary system, and estimation of the position and energy of their collisions against the reactor vessel or the like. (2). Valve leak monitoring: Detection of leaks from primary valves in the primary cooling boundary, such as the pressurizer relief valve and safety valve, and estimation of the form of the leaks. (3). Detector noise response diagnosis: Diagnosis of degradation of principal process detectors during plant operation. Furthermore, a diagnostic system incorporating the above diagnostic technology applicable to actual plants has been experimentally manufactured and successfully verified. (author)

  9. LHD neutron diagnostics

    International Nuclear Information System (INIS)

    Isobe, M.; Ogawa, K.; Kobuchi, T.

    2015-01-01

    The Large Helical Device (LHD) project will step into a next stage, i.e. experiment by using deuterium gases after two years of preparation. A comprehensive set of neutron and γ-ray diagnostics is going to be installed on the LHD towards extension of energetic-particle (EP) physics research in heliotron plasmas. Conceptual design of fusion products diagnostics for the LHD was made in late 1990s. After conclusion of agreements for the LHD deuterium experiment with local government bodies, development of FPs diagnostics has begun lately. Because there are a lot of tasks to do, all Japan fusion neutron and γ-ray diagnostics team has been organized in the collaboration framework of National Institute for Fusion Science. FPs diagnostics system on the LHD will consist of 1) wide dynamic range neutron flux monitor (NFM), 2) neutron activation system (NAS), 3) vertical neutron camera (VNC). In addition to these, we are developing a directional scintillating fiber detector, an artificial diamond detector and a γ-ray scintillation detector for confinement study of MeV ions. A neutron energy spectrometer prototype is also being developed and tested in KSTAR. In this paper, roles of NFM, NAS and VNC and current status of implementation onto the LHD are briefly described. (author)

  10. Design and expected performance of the new SLS beam size monitor

    CERN Document Server

    Milas, N.; Saa Hernandez, A.; Schlott, V.; Streun, A.; Andersson, A.; Breunlin, J.

    2012-01-01

    The vertical emittance minimization campaign at SLS, realized in the context of the TIARA WP6, has already achieved the world's smallest vertical beam size of 3.6 μm, corresponding to a vertical emittance of 0.9 pm, in a synchrotron light source. The minimum value reached for the vertical emittance is only about five times larger than the quantum limit of 0.2 pm. However, the resolution limit of the present SLS emittance monitor has also been reached during this campaign, thus, to further continue the emittance minimization program the construction of an improved second monitor is necessary. In this paper we present the design and studies on the performance of this new monitor based on the image formation method using vertically polarized synchrotron radiation in the visible and UV spectral ranges. This new monitor includes an additional feature, providing the possibility of performing full interferometric measurement by the use of a set of vertical obstacles that can be driven on the light path. Simulations...

  11. Plug-and-play monitoring and performance optimization for industrial automation processes

    CERN Document Server

    Luo, Hao

    2017-01-01

    Dr.-Ing. Hao Luo demonstrates the developments of advanced plug-and-play (PnP) process monitoring and control systems for industrial automation processes. With aid of the so-called Youla parameterization, a novel PnP process monitoring and control architecture (PnP-PMCA) with modularized components is proposed. To validate the developments, a case study on an industrial rolling mill benchmark is performed, and the real-time implementation on a laboratory brushless DC motor is presented. Contents PnP Process Monitoring and Control Architecture Real-Time Configuration Techniques for PnP Process Monitoring Real-Time Configuration Techniques for PnP Performance Optimization Benchmark Study and Real-Time Implementation Target Groups Researchers and students of Automation and Control Engineering Practitioners in the area of Industrial and Production Engineering The Author Hao Luo received the Ph.D. degree at the Institute for Automatic Control and Complex Systems (AKS) at the University of Duisburg-Essen, Germany, ...

  12. Performance monitoring and error significance in patients with obsessive-compulsive disorder.

    Science.gov (United States)

    Endrass, Tanja; Schuermann, Beate; Kaufmann, Christan; Spielberg, Rüdiger; Kniesche, Rainer; Kathmann, Norbert

    2010-05-01

    Performance monitoring has been consistently found to be overactive in obsessive-compulsive disorder (OCD). The present study examines whether performance monitoring in OCD is adjusted with error significance. Therefore, errors in a flanker task were followed by neutral (standard condition) or punishment feedbacks (punishment condition). In the standard condition patients had significantly larger error-related negativity (ERN) and correct-related negativity (CRN) ampliudes than controls. But, in the punishment condition groups did not differ in ERN and CRN amplitudes. While healthy controls showed an amplitude enhancement between standard and punishment condition, OCD patients showed no variation. In contrast, group differences were not found for the error positivity (Pe): both groups had larger Pe amplitudes in the punishment condition. Results confirm earlier findings of overactive error monitoring in OCD. The absence of a variation with error significance might indicate that OCD patients are unable to down-regulate their monitoring activity according to external requirements. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Reducing BWR O and M costs through on-line performance monitoring

    International Nuclear Information System (INIS)

    Jonas, T.; Gross, R.; Logback, F.; Josyula, R.

    1995-01-01

    Competition in the electric power industry has placed significant emphasis on reducing operating and maintenance (O and M) costs at nuclear facilities. Therefore, on-line performance monitoring to locate power losses for boiling water reactor (BWR) plants is creating tremendous interest. In addition, the ability to automate activities such as data collection, analysis, and reporting increases the efficiency of plant engineers and gives them more time to concentrate on solving plant efficiency problems. This capability is now available with a unique software product called GEBOPS. GE Nuclear Energy, in conjunction with Joint Venture partner Black and Veatch, has undertaken development of the General Electric/Black and Veatch On-line Performance System (GEBOPS), an on-line performance monitoring system for BWR plants. The experience and expertise of GE Nuclear Energy with BWR plants, coupled with the proven on-line monitoring software development experience and capability of Black and Veatch, provide the foundation for a unique product which addresses the needs of today's BWR plants

  14. Monitoring of performance and training in rowing.

    Science.gov (United States)

    Mäestu, Jarek; Jürimäe, Jaak; Jürimäe, Toivo

    2005-01-01

    Rowing is a strength-endurance type of sport and competition performance depends on factors such as aerobic and anaerobic power, physical power, rowing technique and tactics. Therefore, a rower has to develop several capacities in order to be successful and a valid testing battery of a rower has to include parameters that are highly related to rowing performance. Endurance training is the mainstay in rowing. For the 2000 m race, power training at high velocities should be preferred to resistance training at low velocities in order to train more specifically during the off-season. The specific training of the international rower has to be approximately 70% of the whole training time. Several studies have reported different biochemical parameters for monitoring the training of rowers. There is some evidence that plasma leptin is more sensitive to training volume changes than specific stress hormones (e.g. cortisol, testosterone, growth hormone). In rowing, the stress hormone reactions to training volume and/or intensity changes are controversial. The Recovery-Stress Questionnaire for Athletes measures both stress and recovery, and may therefore be more effective than the previously used Borg ratio scale or the Profile of Mood States, which both focus mainly on the stress component. In the future, probably the most effective way to evaluate the training of rowers is to monitor both stress and recovery components at the same time, using both psychometric data together with the biochemical and performance parameters.

  15. Development and implementation of a PV performance monitoring system based on inverter measurements

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Gavriluta, Anamaria Florina; Maaløe, Lars

    2016-01-01

    Performance monitoring and fault detection systems have become necessary for decreasing operation and maintenance cost in large photovoltaic (PV) plants, as well for maximizing plan yield and lifetime. We expect a similar development for residential and commercial PV system applications, where...... the inverter’s own monitoring and communication capabilities. We also aim to lower the implementation cost, by using a simple, but accurate performance monitoring approach, and show the practical issues that can arise when implementing such a system....

  16. Vibration-based monitoring for performance evaluation of flexible civil structures in Japan

    Science.gov (United States)

    FUJINO, Yozo

    2018-01-01

    The vibration-based monitoring of flexible civil structures and performance evaluation from this monitoring are reviewed, with an emphasis on research and practice in Japan and the author’s experiences. Some new findings and unexpected vibrations from the monitoring of real bridges and buildings are reported to emphasize the importance of monitoring. Future developments and applications of vibration-based monitoring to civil infrastructure management are also described. Many examples are taken from the author’s past 30 years’ experience of research on bridge dynamics. PMID:29434082

  17. On-line valve monitoring at the Ormen Lange gas plant

    Energy Technology Data Exchange (ETDEWEB)

    Greenlees, R.; Hale, S. [Score Atlanta Inc., Kennesaw, Georgia (United States)

    2011-07-01

    The purpose of this presentation is to discuss replacing time and labor intensive nuclear outage activities with on line condition monitoring solutions, primarily the periodic verification of MOV functionality discussed in USNRC Generic Letter 96.05. This regulation requires that MOV age related performance degradations are properly identified and accounted for, causing utilities to have to retest valves periodically for the duration of the plants operating license. AECL designed CANDU reactors have a world class performance and safety record, with typical average annual capacity factors of 90%. The CANDU reactor design has the ability to refuel on line, as a result (a) it can be a challenge scheduling all required valve testing into limited duration outage work windows, (b) at multi unit sites, Unit 0 valves can be difficult to test because they are rarely ever out of service, (c) deuterium-oxide (heavy water) moderator is expensive to manufacture, as a result, effective through valve leakage monitoring is essential. These three factors alone make CANDU sites the most suitable candidates for on line valve monitoring systems. Nuclear industry regulations have been instrumental in the development of 'at the valve' diagnostic systems, but diagnostic testing has not typically been utilized to the same degree in other less regulated industries. However, that trend is changing, and the move toward valve diagnostics and condition monitoring has moved fastest in the offshore oil and gas industry on the Norwegian side of the North Sea. The Ormen Lange plant, located on Nyhamna Island on the west coast of Norway, operated by Shell, is one of the worlds most advanced gas processing plants. A stated maintenance goal for the plant is that 70% of the maintenance budget and spend should be based on the results of on line condition monitoring, utilizing monitoring systems equipped with switch sensing, strain gages, hydraulic and pneumatic pressure transducers and

  18. On-line valve monitoring at the Ormen Lange gas plant

    International Nuclear Information System (INIS)

    Greenlees, R.; Hale, S.

    2011-01-01

    The purpose of this presentation is to discuss replacing time and labor intensive nuclear outage activities with on line condition monitoring solutions, primarily the periodic verification of MOV functionality discussed in USNRC Generic Letter 96.05. This regulation requires that MOV age related performance degradations are properly identified and accounted for, causing utilities to have to retest valves periodically for the duration of the plants operating license. AECL designed CANDU reactors have a world class performance and safety record, with typical average annual capacity factors of 90%. The CANDU reactor design has the ability to refuel on line, as a result (a) it can be a challenge scheduling all required valve testing into limited duration outage work windows, (b) at multi unit sites, Unit 0 valves can be difficult to test because they are rarely ever out of service, (c) deuterium-oxide (heavy water) moderator is expensive to manufacture, as a result, effective through valve leakage monitoring is essential. These three factors alone make CANDU sites the most suitable candidates for on line valve monitoring systems. Nuclear industry regulations have been instrumental in the development of 'at the valve' diagnostic systems, but diagnostic testing has not typically been utilized to the same degree in other less regulated industries. However, that trend is changing, and the move toward valve diagnostics and condition monitoring has moved fastest in the offshore oil and gas industry on the Norwegian side of the North Sea. The Ormen Lange plant, located on Nyhamna Island on the west coast of Norway, operated by Shell, is one of the worlds most advanced gas processing plants. A stated maintenance goal for the plant is that 70% of the maintenance budget and spend should be based on the results of on line condition monitoring, utilizing monitoring systems equipped with switch sensing, strain gages, hydraulic and pneumatic pressure transducers and acoustic leakage

  19. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  20. Virtual Resting Pd/Pa From Coronary Angiography and Blood Flow Modelling: Diagnostic Performance Against Fractional Flow Reserve.

    Science.gov (United States)

    Papafaklis, Michail I; Muramatsu, Takashi; Ishibashi, Yuki; Bourantas, Christos V; Fotiadis, Dimitrios I; Brilakis, Emmanouil S; Garcia-Garcia, Héctor M; Escaned, Javier; Serruys, Patrick W; Michalis, Lampros K

    2018-03-01

    Fractional flow reserve (FFR) has been established as a useful diagnostic tool. The distal coronary pressure to aortic pressure (Pd/Pa) ratio at rest is a simpler physiologic index but also requires the use of the pressure wire, whereas recently proposed virtual functional indices derived from coronary imaging require complex blood flow modelling and/or are time-consuming. Our aim was to test the diagnostic performance of virtual resting Pd/Pa using routine angiographic images and a simple flow model. Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by FFR. The resting Pd/Pa for each lesion was assessed by computational fluid dynamics. The discriminatory power of virtual resting Pd/Pa against FFR (reference: ≤0.80) was high (area under the receiver operator characteristic curve [AUC]: 90.5% [95% CI: 85.4-95.6%]). Diagnostic accuracy, sensitivity and specificity for the optimal virtual resting Pd/Pa cut-off (≤0.94) were 84.9%, 90.4% and 81.6%, respectively. Virtual resting Pd/Pa demonstrated superior performance (pvirtual resting Pd/Pa and FFR (r=0.69, pVirtual resting Pd/Pa using routine angiographic data and a simple flow model provides fast functional assessment of coronary lesions without requiring the pressure-wire and hyperaemia induction. The high diagnostic performance of virtual resting Pd/Pa for predicting FFR shows promise for using this simple/fast virtual index in clinical practice. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  1. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT.

    Science.gov (United States)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kaetsu, Yasuhiro; Kitao, Shinichiro; Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro; Ogawa, Toshihide

    2017-07-01

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. • Computed tomography angiography tends to overestimate stenosis in calcified coronary artery. • Dual-energy CT enables us to suppress calcification of coronary artery lesions. • Calcification-suppressed material density imaging reduces false-positive diagnosis of calcified lesion.

  2. Ruling out pulmonary embolism in primary care : Comparison of the diagnostic performance of “gestalt” and the wells rule

    NARCIS (Netherlands)

    Hendriksen, Janneke M T; Lucassen, Wim A M; Erkens, Petra M G; Stoffers, Henri E J H; van Weert, Henk C P M; Büller, Harry R.; Hoes, Arno W.; Moons, Karel G M; Geersing, Geert Jan

    2016-01-01

    PURPOSE Diagnostic prediction models such as the Wells rule can be used for safely ruling out pulmonary embolism (PE) when it is suspected. A physician’s own probability estimate (“gestalt”), however, is commonly used instead. We evaluated the diagnostic performance of both approaches in primary

  3. Elastography for Thyroid Nodules: The Comparison of Diagnostic Performance on Transverse and Longitudinal Planes

    International Nuclear Information System (INIS)

    Moon, Hee Jung; Kwak, Jin Young; Kim, Eun Kyung

    2012-01-01

    To evaluate the diagnostic performance of elastography for thyroid nodules on the transverse and longitudinal planes. Gray scale ultrasonography (US), elastography on trans- verse and longitudinal planes, and fine needle aspiration biopsy for 78 thyroid nodules (malignant: 34 cases, benign: 44 cases) were performed. According to the Asteria criteria of elastography, scores 1 and 2 were classified as probably benign and scores 3 and 4 were classified as suspicious. Strain ratios on transverse and longitudinal planes were measured. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and Az value (under the receiver operating characteristics curve) of elastography on transverse and longitudinal planes were calculated and compared. Scores 3 and 4 were more frequently seen in malignant nodules on the longitudinal plane (p value = 0.007), but not significantly seen on the transverse plane (p value = 0.160). Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and the Az value of elastography on the longitudinal plane were higher than those on the transverse plane, although Az values on the transverse and longtudinal planes were not statistically significant. Diagnostic performance of thyroid elastography, especially sensitivity, were higher on the longitudinal plane than the transverse plane

  4. Self-adapted thermocouple-diagnostic complex

    International Nuclear Information System (INIS)

    Alekseev, S.V.; Grankovskij, K.Eh.; Olejnikov, P.P.; Prijmak, S.V.; Shikalov, V.F.

    2003-01-01

    A self-adapted thermocouple-diagnostic complex (STDC) for obtaining the reliable data on the coolant temperature in the reactors of NPP is described. The STDC in based on the thermal pulse monitoring of a thermocouple in the measuring channel of a reactor. Measurement method and STDC composition are substantiated. It is shown that introduction of the developed STDC ensures realization of precise and reliable temperature monitoring in the reactors of all types [ru

  5. Video profile monitor diagnostic system for GTA

    International Nuclear Information System (INIS)

    Sandoval, D.P.; Garcia, R.C.; Gilpatrick, J.D.; Johnson, K.F.; Shinas, M.A.; Wright, R.; Yuan, V.; Zander, M.E.

    1992-01-01

    This paper describes a video diagnostic system used to measure the beam profile and position of the Ground Test Accelerator 2.5-MeV H - ion beam as it exits the intermediate matching section. Inelastic collisions between H-ions and residual nitrogen to fluoresce. The resulting light is captured through transport optics by an intensified CCD camera and is digitized. Real-time beam-profile images are displayed and stored for detailed analysis. Analyzed data showing resolutions for both position and profile measurements will also be presented

  6. Monitoring individual and joint action outcomes in duet music performance

    DEFF Research Database (Denmark)

    Loehr, Janeen; Kourtis, Dimitrios; Vesper, Cordula

    2013-01-01

    We investigated whether people monitor the outcomes of their own and their partners’ individual actions as well as the outcome of their combined actions when performing joint actions together. Pairs of pianists memorized both parts of a piano duet. Each pianist then performed one part while their...

  7. Monitoring of performance management using Quality Assurance Indicators and ISO requirement

    Directory of Open Access Journals (Sweden)

    Dargahi H

    2007-06-01

    Full Text Available Background: Quality assurance is a prevention-oriented system that can be used to improve the quality of care, increase productivity and monitor the performance management in clinical laboratories. ISO 9001: 2000 requirements are a collection of management and technical systems designed to implement quality assurance and monitor performance management in organizations. Methods: A checklist was prepared to monitor the preanalytical, analytical and postanalytical stages of laboratory performance management in 16 areas and all laboratory activities in 14 of the clinical laboratories of the Tehran University of Medical Sciences (TUMS hospitals. Collected data were stored and statistically analyzed using SPSS software. Results: The best performance, in which 77.73% of quality assurance indicators were observed, was found in Sina Hospital. However, only 57.56% of these indicators were fulfilled at Farabi Hospital, with the lowest-level performance among the clinical laboratories of TUMS hospitals. The highest level of compliance with quality assurance indicators was in the hematology departments and for facility demands in management areas. Overall, quality assurance indicators were appropriately followed in only 7% of the clinical laboratories. Conclusion: The average quality assurance observation rate in the clinical laboratories studied was 67.22%, which is insufficient and must be remedied with stricter enforcement of the ISO 9001: 2000 regulations.

  8. Development of high performance Schottky barrier diode and its application to plasma diagnostics

    International Nuclear Information System (INIS)

    Fujita, Junji; Kawahata, Kazuo; Okajima, Shigeki

    1993-10-01

    At the conclusion of the Supporting Collaboration Research on 'Development of High Performance Detectors in the Far Infrared Range' carried out from FY1990 to FY1992, the results of developing Schottky barrier diode and its application to plasma diagnostics are summarized. Some remarks as well as technical know-how for the correct use of diodes are also described. (author)

  9. Performance Monitoring Techniques Supporting Cognitive Optical Networking

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Borkowski, Robert; Zibar, Darko

    2013-01-01

    High degree of heterogeneity of future optical networks, such as services with different quality-of-transmission requirements, modulation formats and switching techniques, will pose a challenge for the control and optimization of different parameters. Incorporation of cognitive techniques can help...... to solve this issue by realizing a network that can observe, act, learn and optimize its performance, taking into account end-to-end goals. In this letter we present the approach of cognition applied to heterogeneous optical networks developed in the framework of the EU project CHRON: Cognitive...... Heterogeneous Reconfigurable Optical Network. We focus on the approaches developed in the project for optical performance monitoring, which enable the feedback from the physical layer to the cognitive decision system by providing accurate description of the performance of the established lightpaths....

  10. Transient ischemic attack: diagnostic evaluation.

    Science.gov (United States)

    Messé, Steven R; Jauch, Edward C

    2008-08-01

    A transient ischemic attack portends significant risk of a stroke. Consequently, the diagnostic evaluation in the emergency department is focused on identifying high-risk causes so that preventive strategies can be implemented. The evaluation consists of a facilitated evaluation of the patient's metabolic, cardiac, and neurovascular systems. At a minimum, the following tests are recommended: fingerstick glucose level, electrolyte levels, CBC count, urinalysis, and coagulation studies; noncontrast computed tomography (CT) of the head; electrocardiography; and continuous telemetry monitoring. Vascular imaging studies, such as carotid ultrasonography, CT angiography, or magnetic resonance angiography, should be performed on an urgent basis and prioritized according to the patient's risk stratification for disease. Consideration should be given for echocardiography if no large vessel abnormality is identified.

  11. Tractor performance monitor based on a single-chip microcomputer

    Energy Technology Data Exchange (ETDEWEB)

    Bedri, A.R.; Marley, S.J.; Buchelle, W.F.; Smay, T.A.

    1981-01-01

    A tractor performance monitor based on a single-chip microcomputer was developed to measure ground speed, slip, fuel consumption (rate and total), total area, theoretical time, and total time. Transducers used are presented in detail. 5 refs.

  12. Cluster analysis of received constellations for optical performance monitoring

    NARCIS (Netherlands)

    van Weerdenburg, J.J.A.; van Uden, R.; Sillekens, E.; de Waardt, H.; Koonen, A.M.J.; Okonkwo, C.

    2016-01-01

    Performance monitoring based on centroid clustering to investigate constellation generation offsets. The tool allows flexibility in constellation generation tolerances by forwarding centroids to the demapper. The relation of fibre nonlinearities and singular value decomposition of intra-cluster

  13. Diagnostic and monitoring systems in nuclear power plants

    International Nuclear Information System (INIS)

    Wehling, H.J.; Jax, P.; Streicher, V.

    1987-01-01

    Monitoring systems are important for the availability of nuclear power plants. A survey is given about such systems designed and constructed by the Kraftwerk Union AG Erlangen (Federal Republic of Germany) in order to assure the mechanical integrity of reactor cooling systems. Three monitoring systems based on microprocessors are presented: KUES (acoustic detection of loose parts), SUES (vibration), and FAMOS (fatigue)

  14. Experiences with 'on-line' diagnostic instrumentation in nuclear power plants

    International Nuclear Information System (INIS)

    Gopal, R.; Ciaramitaro, W.; Smith, J.R.

    1981-01-01

    Over the past several years, Westinghouse has developed a coordinated system of on-line diagnostic instrumentation for the acquisition and analysis of data for diagnostics and incipient failure detection of critical plant equipment and systems. Primary motivation for this work is to improve Nuclear Steam Supply System (NSSS) availability and maintainability through the detection of malfunctions at their inception. These systems include: 1) Acoustic leak monitoring for detection and location of leaks in the primary system pressure boundary and other piping systems in PWR's; 2) Metal impact monitoring for detection of loose debris in the reactor vessel and steam generators; 3) Nuclear noise monitoring for monitoring core barrel vibration. Summarized in this paper are some of the features of the systems and inplant experience. (author)

  15. Link Performance Analysis and monitoring - A unified approach to divergent requirements

    Science.gov (United States)

    Thom, G. A.

    Link Performance Analysis and real-time monitoring are generally covered by a wide range of equipment. Bit Error Rate testers provide digital link performance measurements but are not useful during real-time data flows. Real-time performance monitors utilize the fixed overhead content but vary widely from format to format. Link quality information is also present from signal reconstruction equipment in the form of receiver AGC, bit synchronizer AGC, and bit synchronizer soft decision level outputs, but no general approach to utilizing this information exists. This paper presents an approach to link tests, real-time data quality monitoring, and results presentation that utilizes a set of general purpose modules in a flexible architectural environment. The system operates over a wide range of bit rates (up to 150 Mbs) and employs several measurement techniques, including P/N code errors or fixed PCM format errors, derived real-time BER from frame sync errors, and Data Quality Analysis derived by counting significant sync status changes. The architecture performs with a minimum of elements in place to permit a phased update of the user's unit in accordance with his needs.

  16. Recent advances in control and diagnostics development and application

    International Nuclear Information System (INIS)

    Monson, L.R.; King, R.W.; Lindsay, R.W.; Staffon, J.D.

    1989-01-01

    The power industry is undergoing rapid technological advances and cultural changes. Technologies are advancing and evolving so rapidly that the industry is hard pressed to keep up and take full advantage of the many developments now in progress. Recent advantages in state-of-the-art computer technology are making in-roads in the form of advanced computer control, expert systems, on-line performance monitoring and diagnostics. Validation and verification schemes are being developed which provide increased confidence in the correctness and reliability of both computer hardware and software. Our challenge in the nuclear community is to effectively apply these new technologies to improve the operation, safety, and reliability of our plants. This presentation discusses two areas of development that are essential to advanced control strategies: application of diagnostic systems to improve fault-tolerance, and model-based graphic displays. 4 refs., 4 figs

  17. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

    International Nuclear Information System (INIS)

    Létourneau, Daniel; McNiven, Andrea; Keller, Harald; Wang, An; Amin, Md Nurul; Pearce, Jim; Norrlinger, Bernhard; Jaffray, David A.

    2014-01-01

    Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves

  18. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    Science.gov (United States)

    Létourneau, Daniel; Wang, An; Amin, Md Nurul; Pearce, Jim; McNiven, Andrea; Keller, Harald; Norrlinger, Bernhard; Jaffray, David A

    2014-12-01

    High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3-4 times/week over a period of 10-11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ± 0.5 and ± 1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. The precision of the MLC performance monitoring QC test and the MLC itself was within ± 0.22 mm for most MLC leaves and the majority of the

  19. A monitoring tool for performance improvement in plastic surgery at the individual level.

    Science.gov (United States)

    Maruthappu, Mahiben; Duclos, Antoine; Orgill, Dennis; Carty, Matthew J

    2013-05-01

    The assessment of performance in surgery is expanding significantly. Application of relevant frameworks to plastic surgery, however, has been limited. In this article, the authors present two robust graphic tools commonly used in other industries that may serve to monitor individual surgeon operative time while factoring in patient- and surgeon-specific elements. The authors reviewed performance data from all bilateral reduction mammaplasties performed at their institution by eight surgeons between 1995 and 2010. Operative time was used as a proxy for performance. Cumulative sum charts and exponentially weighted moving average charts were generated using a train-test analytic approach, and used to monitor surgical performance. Charts mapped crude, patient case-mix-adjusted, and case-mix and surgical-experience-adjusted performance. Operative time was found to decline from 182 minutes to 118 minutes with surgical experience (p factors is essential for correct interpretation of performance in plastic surgery at the individual surgeon level. Cumulative sum and exponentially weighted moving average charts represent accurate methods of monitoring operative time to control and potentially improve surgeon performance over the course of a career.

  20. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    International Nuclear Information System (INIS)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo

    2010-01-01

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  1. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo [East-West Neo Medical Center, Kyung-Hee University, Seoul (Korea, Republic of)

    2010-03-15

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  2. 32 CFR 34.41 - Monitoring and reporting program and financial performance.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Monitoring and reporting program and financial performance. 34.41 Section 34.41 National Defense Department of Defense OFFICE OF THE SECRETARY OF DEFENSE DoD... ORGANIZATIONS Post-award Requirements Reports and Records § 34.41 Monitoring and reporting program and financial...

  3. On-line condition monitoring of nuclear systems via symbolic time series analysis

    International Nuclear Information System (INIS)

    Rajagopalan, V.; Ray, A.; Garcia, H. E.

    2006-01-01

    This paper provides a symbolic time series analysis approach to fault diagnostics and condition monitoring. The proposed technique is built upon concepts from wavelet theory, symbolic dynamics and pattern recognition. Various aspects of the methodology such as wavelet selection, choice of alphabet and determination of depth of D-Markov Machine are explained in the paper. The technique is validated with experiments performed in a Machine Condition Monitoring (MCM) test bed at the Idaho National Laboratory. (authors)

  4. Xanthogranulomatous cholecystitis: Diagnostic performance of CT to differentiate from gallbladder cancer

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi, E-mail: gossy@par.odn.ne.j [Department of Radiology, University of Pittsburgh Medical Center, Lothrop St., Pittsburgh, PA 15213 (United States); Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); Chang, Samuel; Wang, Jin Hong [Department of Radiology, University of Pittsburgh School of Medicine, 3362 Fifth Ave., Pittsburgh, PA15213 (United States); Kanematsu, Masayuki [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan); Department of Radiology Services, Gifu University School of Medicine, 1-1- Yanagido, Gifu 501-1194 (Japan); Bae, Kyongtae T. [Department of Radiology, University of Pittsburgh School of Medicine, 3362 Fifth Ave., Pittsburgh, PA15213 (United States); Federle, Michael P. [Department of Radiology, University of Pittsburgh Medical Center, Lothrop St., Pittsburgh, PA 15213 (United States); Department of Radiology, Stanford University Medical Center, 300 Pasteur Drive, Stanford, CA 94305-5105 (United States)

    2010-06-15

    Purpose: To retrospectively evaluate CT findings of xanthogranulomatous cholecystitis (XGC) and to measure diagnostic performance for distinguishing it from gallbladder (GB) cancer. Methods and materials: Our institutional review board approved this retrospective study. Three blinded radiologists, first independently and then in consensus, retrospectively evaluated postcontrast CT images of 35 patients with histopathologically proved XGC and GB cancer, all of whom subsequently had cholecystectomy. These included 18 patients with XGC (13 male, 5 female; age range, 35-84, mean 63 years) and 17 with GB cancer (6 male, 11 female; age range, 45-95, mean 69). Differences in CT findings between XGC and GB cancer and diagnostic performances for each CT finding were calculated. Sensitivity, specificity, and accuracy were calculated for each radiologist and observer performance was also determined by receiver-operating-characteristic curve analysis. Results: Five CT findings showed significant differences between XGC and GB cancer. Sensitivity, specificity, and accuracy of each finding for the differentiation of XGC were 89%, 65%, 77% with diffuse GB wall thickening, 67%, 82%, 74% with a continuous mucosal line, 61%, 71%, 66% with intra-mural hypo-attenuated nodules, 72%, 77%, 74% with absence of macroscopic hepatic invasion, and 67%, 71%, 69% with absence of intra-hepatic bile duct dilatation, respectively. When at least three of these five CT findings were observed in combination, sensitivity, specificity, and accuracy were 83%, 100% and 91%, respectively. Sensitivities, specificities and Az values for the differentiation of XGC from GB cancer were 83%, 88%, 0.94 for reader 1, 78%, 88%, 0.93 for reader 2, and 78%, 82%, 0.84 for reader 3. Conclusions: The combination of three of the five CT findings that are common with XGC can provide excellent accuracy for the differentiation of XGC and GB cancer.

  5. Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis.

    Science.gov (United States)

    Kim, Mi Sung; Kwon, Heon-Ju; Kang, Kyung A; Do, In-Gu; Park, Hee-Jin; Kim, Eun Young; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Young Hwan

    2018-02-01

    To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis. Advances in knowledge: Ultrasound re-evaluation is useful to discriminate appendicitis from non-appendicitis when CT features are inconclusive.

  6. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stages 14 and 15

    International Nuclear Information System (INIS)

    Pazsit, Imre; Wihlstrand, Gustav; Tambouratzis, Tatiana; Jonsson, Anders; Dahl, Berit

    2009-12-01

    This report constitutes Stages 14 and 15 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. Stage 14 was a full one-year project, whereas Stage 15 consisted of a half-year project. The program executed in Stages 14 and 15 consists of the following three parts: - Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR) (Stages 14 and 15); - An overview and introduction to fuzzy logics (Stage 14), and an application to two-phase flow identification (Stage 15) - Preparations for and execution of an IAEA-ICTP workshop on Neutron fluctuations, reactor noise and their applications in nuclear reactors (Stage 14)

  7. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stages 14 and 15

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, Imre; Wihlstrand, Gustav; Tambouratzis, Tatiana; Jonsson, Anders; Dahl, Berit (Chalmers Univ. of Technology, Dept. of Nuclear Engineering, SE-412 96 Goeteborg (Sweden))

    2009-12-15

    This report constitutes Stages 14 and 15 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. Stage 14 was a full one-year project, whereas Stage 15 consisted of a half-year project. The program executed in Stages 14 and 15 consists of the following three parts: - Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR) (Stages 14 and 15); - An overview and introduction to fuzzy logics (Stage 14), and an application to two-phase flow identification (Stage 15) - Preparations for and execution of an IAEA-ICTP workshop on Neutron fluctuations, reactor noise and their applications in nuclear reactors (Stage 14)

  8. Monitoring ARC services with GangliARC

    International Nuclear Information System (INIS)

    Cameron, D; Karpenko, D

    2012-01-01

    Monitoring of Grid services is essential to provide a smooth experience for users and provide fast and easy to understand diagnostics for administrators running the services. GangliARC makes use of the widely-used Ganglia monitoring tool to present web-based graphical metrics of the ARC computing element. These include statistics of running and finished jobs, data transfer metrics, as well as showing the availability of the computing element and hardware information such as free disk space left in the ARC cache. Ganglia presents metrics as graphs of the value of the metric over time and shows an easily-digestable summary of how the system is performing, and enables quick and easy diagnosis of common problems. This paper describes how GangliARC works and shows numerous examples of how the generated data can quickly be used by an administrator to investigate problems. It also presents possibilities of combining GangliARC with other commonly-used monitoring tools such as Nagios to easily integrate ARC monitoring into the regular monitoring infrastructure of any site or computing centre.

  9. Development of high-performance monitoring system under severe accident condition

    International Nuclear Information System (INIS)

    Takeuchi, Tomoaki; Tsuchiya, Kunihiro; Ishihara, Masahiro; Komanome, H.; Miura, K.

    2017-01-01

    A research and development of a monitoring system for NPPs situations even during severe accidents have been performed. The R and D consists of the three objectives. The major findings are briefly summarized in the followings: 1) Radiation-resistant monitoring camera. The image sensor with the photogate and three transistors was found to be advantageous in terms of dark current and sensitivity. In addition, radiation-resistant optical parts and signal circuits were successfully fabricated. The results suggested that the monitoring camera system with 10 6 Gy in radiation resistance was possible. 2) Radiation-resistant in-water wireless transmission system. A two-dimensional LED matrix with 10 6 Gy in radiation resistance and a camera were used as the transmission devices. The results of the in-water transmission tests suggested that stable wireless transmission between 5 m distance was possible even with bubble, turbidity, or obstacles. 3) Heat-resistant signal cable. In order to develop a cable that can transmit the data inside reactor pressure vessels, heat-proof tests were performed for candidate metallic sheath materials of mineral insulation (MI) cables. The results indicated MI cables which can be used at 1000degC in air were possible. These results indicate the feasibility of the monitoring system even during severe accidents. (author)

  10. Monitoring of ionospheric turbulence spatial features by SEE diagnostic tools

    Science.gov (United States)

    Sergeev, E. N.; Boiko, G. N.; Shvarts, M. M.; Grach, S. M.; Kotov, P. V.

    Spatial features of HF pumped ionospheric F-region are investigated experimentally at the SURA facility by means of the stimulated electromagnetic emission (SEE). SEE, recall, appears as a result of conversion (or scattering) of HF pump-driven plasma waves off the geomagnetic field aligned electron density irregularities (striations). A specially designed pumping scheme was elaborated to study an influence of the perturbations of the electron density and temperature, created by powerful pump wave at frequency f_h and occupying quite extended altitude range (range-I), on spectral and temporal evolution of the diagnostic SEE (DSEE) generated by a weak continuous or pulse diagnostic wave at a frequency f_d in an altitude range-II, spatially shifted from the centre of the range-I. New two-channel digital receiver allowed to analyze the SEE from both ranges (around both frequencies f_h and f_d) simultaneously. A combination of the SEE diagnostics and computer simulations allowed to study:% (a) dependences of striation spectrum and dynamics on the frequency shift |f_h-f_d| (which can be easily translated to the altitude displacement), powers of the pump and diagnostic waves, offsets of the frequencies f_h and f_d from electron gyroharmonics, and on the daily conditions. It is found that a slow (time scale of 1--10 s) dynamics of DSEE, namely, characteristics of its slow overshoot and undershoot effects are determined by the spectral shape and intensity of the striations at, respectively, the development and relaxation stages. It is shown that the striation spectrum flattens in meter scale range for f_h between 3th and 4th gyroharmonics in comparison with larger f_h, in the centre of the range-I in comparison with its periphery, that the range-I extension increases with its altitude and with a transition from day to night conditions;% (b) an influence of the powerful pumping on ``diagnostic'' HF plasma wave evolution by measurements of growth and decay times of the DSEE

  11. Do conventional monitoring practices indicate in situ air sparging performance?

    International Nuclear Information System (INIS)

    Johnson, P.C.

    1995-01-01

    Short-term pilot tests play a key role in the selection and design of in situ air sparging systems. Most pilot tests are less than 24 h in duration and consist of monitoring changes in dissolved oxygen, water levels in wells, soil gas pressures, and soil gas contaminant concentrations while air is injected into the aquifer. These parameters are assumed to be indicators of air sparging feasibility and performance, and are also used in the design of full-scale systems. In this work the authors assess the validity of this critical assumption. Data are presented from a study site where a typical pilot-scale short-term test was conducted, followed by continued operation of a full-scale system for 110 days. Conventional sampling practices were augmented with more discrete and detailed assessment methods. In addition, a tracer gas was used to better understand air distributions, vapor flow paths, and vapor recovery efficiency. The data illustrate that conclusions regarding the performance and applicability of air sparging at the study site vary significantly depending on the monitoring approach used. There was no clear correlation between short-term pilot-test data and extended system performance when using data collected only from conventional groundwater monitoring wells. Attention is focused on petroleum hydrocarbons

  12. Quality control of the interpretation monitors of digital radiological images; Controle de qualidade dos monitores de interpretacao de imagens radiologicas digitais: uma revisao

    Energy Technology Data Exchange (ETDEWEB)

    Favero, Mariana S.; Goulart, Adriano Oliveira S., E-mail: mariana@phymed.com.br [PhyMED - Consultores em Fisica Medica e Radioprotecao Ltda, Porto Alegre, RS (Brazil)

    2016-07-01

    The performance monitors has great importance in image quality of digital radiographic systems. In environments without films, it became necessary to implement acceptance testing and quality control monitors used for interpretation of medical images. The monitors dedicated to radiodiagnostic should provide information that represent slight differences in x-ray attenuation or minor differences in some anatomical region of interest. This should also result in small differences in luminance of an image represented. Factors affecting the quality of medical imaging are contrast, noise, resolution, artifacts and distortions. Therefore, a monitor must have specific characteristics, making it possible for the observer to carry out an assessment that leads to better diagnosis. Based on the need to evaluate diagnostic monitors in various radiological applications, this paper presents a summary for implementation and standardization of tests that are recommended by the publication AAPM Report 03. (author)

  13. Utility of DWI with quantitative ADC values in ovarian tumors: a meta-analysis of diagnostic test performance.

    Science.gov (United States)

    Pi, Shan; Cao, Rong; Qiang, Jin Wei; Guo, Yan Hui

    2018-01-01

    Background Diffusion-weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) values are widely used in the differential diagnosis of ovarian tumors. Purpose To assess the diagnostic performance of quantitative ADC values in ovarian tumors. Material and Methods PubMed, Embase, the Cochrane Library, and local databases were searched for studies assessing ovarian tumors using quantitative ADC values. We quantitatively analyzed the diagnostic performances for two clinical problems: benign vs. malignant tumors and borderline vs. malignant tumors. We evaluated diagnostic performances by the pooled sensitivity and specificity values and by summary receiver operating characteristic (SROC) curves. Subgroup analyses were used to analyze study heterogeneity. Results From the 742 studies identified in the search results, 16 studies met our inclusion criteria. A total of ten studies evaluated malignant vs. benign ovarian tumors and six studies assessed malignant vs. borderline ovarian tumors. Regarding the diagnostic accuracy of quantitative ADC values for distinguishing between malignant and benign ovarian tumors, the pooled sensitivity and specificity values were 0.91 and 0.91, respectively. The area under the SROC curve (AUC) was 0.96. For differentiating borderline from malignant tumors, the pooled sensitivity and specificity values were 0.89 and 0.79, and the AUC was 0.91. The methodological quality of the included studies was moderate. Conclusion Quantitative ADC values could serve as useful preoperative markers for predicting the nature of ovarian tumors. Nevertheless, prospective trials focused on standardized imaging parameters are needed to evaluate the clinical value of quantitative ADC values in ovarian tumors.

  14. The effect of question format and task difficulty on reasoning strategies and diagnostic performance in Internal Medicine residents.

    Science.gov (United States)

    Heemskerk, Laura; Norman, Geoff; Chou, Sophia; Mintz, Marcy; Mandin, Henry; McLaughlin, Kevin

    2008-11-01

    Previous studies have suggested an association between reasoning strategies and diagnostic success, but the influence on this relationship of variables such as question format and task difficulty, has not been studied. Our objective was to study the association between question format, task difficulty, reasoning strategies and diagnostic success. Study participants were 13 Internal Medicine residents at the University of Calgary. Each was given eight problem-solving questions in four clinical presentations and were randomized to groups that differed only in the question format, such that a question presented as short answer (SA) to the first group was presented as extended matching (EM) to the second group. There were equal numbers of SA/EM questions and straightforward/difficult tasks. Participants performed think-aloud during diagnostic reasoning. Data were analyzed using multiple logistic regression. Question format was associated with reasoning strategies; hypothetico-deductive reasoning being used more frequently on EM questions and scheme-inductive reasoning on SA questions. For SA question, non-analytic reasoning alone was used more frequently to answer straightforward cases than difficult cases, whereas for EM questions no such association was observed. EM format and straightforward task increased the odds of diagnostic success, whereas hypothetico-deductive reasoning was associated with reduced odds of success. Question format and task difficulty both influence diagnostic reasoning strategies and studies that examine the effect of reasoning strategies on diagnostic success should control for these effects. Further studies are needed to investigate the effect of reasoning strategies on performance of different groups of learners.

  15. New portable monitor enhances the ability to evaluate heat exchanger performance

    International Nuclear Information System (INIS)

    O'Toole, W.; Lacy, J.R.; Karlovich, D.N.

    1992-01-01

    Corrosion and fouling problems in nuclear power plant service water systems have led to industry-wide concern. These problems can affect the ability of these important heat exchangers to remove design heat loads. In addition, a limited amount of permanently installed on-line instrumentation is available to monitor key heat transfer parameters. A new, computerized monitoring system has been developed that acquires and manipulates process data. This enables power plant personnel to evaluate the on-line performance of important cooling system heat exchangers. The equipment provides the capability to continuously monitor, graph, and record cooling and process heat transfer parameters. The computer hardware is in a portable cabinet on wheels, which can be easily rolled from exchanger to exchanger for monitoring. This new monitoring system is being used at Consolidated Edison Company of New York Inc.'s Indian Point 2 Nuclear Station. They are currently expanding their performance testing on service water system heat exchangers and other auxiliary components to include those units that have limited on-line instrumentation. The ability to use clamp on flow and temperature sensing devices is necessary for trending exchanger performance. With on-line testing capabilities it is possible to: evaluate the cleanliness of plant heat transfer surfaces; make judgments about biofouling or antiscalant programs; and determine when equipment needs to be shut down for inspection or cleaning This paper describes this state-of-the-art equipment in detail and its application at the Indian Point 2 Nuclear Station. 9 refs., 8 figs., 1 tab

  16. Quality control of conventional diagnostic radiology equipment in Serbia and Montenegro

    International Nuclear Information System (INIS)

    Ciraj, O.; Kosutic, D.; Markovic, S.

    2003-01-01

    There are more than 1500 diagnostic X-ray tubes in service in Serbia and Montenegro. Diagnostic X-ray equipment is checked on annual basis. X-ray equipment Qc protocols have been adopted from several international standards and guidelines [1,2], which have been modified according our practice and measuring equipment. According our inventory, about one half of all installed units is used for conventional X-ray diagnostics, 10% are mobile units, 2% of all in units in operation are mammographic devices an another 2% are computed tomography units. In addition there are about 600 dental X-ray units, which is 36% of all units. It is worth mentioning that almost 30 % of all installed units have single-phase generators, another 25% are tree phase (six and twelve pulse) generators and nearly 9% are high frequency units. Majority of units was installed more than 25 years ago. The Quality Control (QC) in radiography is a central part of QA programme, which deals with equipment maintenance and monitoring. QA in diagnostic radiology is a mean of maintaining standards in imaging and working towards minimizing patient and staff doses. As a part of QA programme in diagnostic radiology, the performance characteristics of 96 conventional X-ray units were measured in six months period during 2003. The diagnostic units were located in hospitals all over the country. They represent 25% of the total conventional diagnostic units of the country. About one half of measured X-ray units were new-installed. QC program has positive effect on X-ray equipment performance in a period of a few years. It is essential to perform QC tests for all installed X-ray units at least on annual basis. This would lead to production of consistent X-ray images, with minimal retake rate and hence, will contribute to decreasing of the patient dose. Patient doses are determined by multitude factors which interact in very complicated manner. It is very important to perform real patient dose measurements in

  17. Nuclear reactor pump diagnostics via noise analysis/artificial neural networks

    International Nuclear Information System (INIS)

    Keyvan, S.; Rabelo, L.C.

    1991-01-01

    A feasibility study is performed on the utilization of artificial neural networks as a tool for reactor diagnostics. Reactor pump signals utilized in a wear-out monitoring system developed for early detection of degradation of pump shaft are analyzed as a semi-benchmark test to study the feasibility of neural networks for pattern recognition. The Adaptive Resonance Theory (ART 2) paradigm of artificial neural networks is applied in this study. The signals are collected signals as well as generated signals simulating the wear progress. The wear-out monitoring system applies noise analysis techniques, and is capable of distinguishing between these signals and providing a measure of the progress of the degradation. This paper presents the results of the analysis of these data via the ART 2 paradigm

  18. Preclinical study of diagnostic performances of contrast-enhanced spectral mammography versus MRI for breast diseases in China.

    Science.gov (United States)

    Wang, Qingguo; Li, Kangan; Wang, Lihui; Zhang, Jianbing; Zhou, Zhiguo; Feng, Yan

    2016-01-01

    To evaluate diagnostic performances of CESM for breast diseases with comparison to breast MRI in China. Sixty-eight patients with 77 breast lesions underwent MR and CESM. Two radiologists interpreted either MRI or CESM images, separately and independently. BI-RADS 1-3 and BI-RADS 4-5 were classified into the suspicious benign and suspicious malignant groups. Diagnostic accuracy parameters were calculated. Receiver operating characteristic (ROC) curves were constructed for the two modalities. The agreement and correlation between maximum lesion diameter based on CESM and MRI, or CESM and pathology were analyzed. Diagnostic accuracy parameters for CESM were sensitivity 95.8 %, specificity 65.5 %, PPV 82.1 %, NPV 90.5 % and accuracy 84.4 %. The diagnostic accuracy parameters for breast MRI were sensitivity 93.8 %, specificity 82.8 %, PPV 88.2 %, NPV 92.3 %and accuracy 89.6 %. Area under the curve (AUC) of ROC was 0.96 for breast MRI and 0.88 for CESM. The Bland-Altman plots showed a mean difference of 0.7 mm with 95 % limits of agreement of 11.4 mm in tumor diameter measured using CESM and breast MRI. The differences of size measurement between CESM and breast MRI were significant, whereas no difference was observed between CESM and pathology as well as between breast MRI and pathology. The better correlation with pathological results was found in CESM than breast MRI. Our study demonstrates that CESM possesses better diagnostic performances than breast MRI in terms of diagnostic sensitivity and lesion size assessment. And CESM is a good alternative method of screening breast cancer in high-risk people.

  19. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  20. Clinical validation of a medical grade color monitor for chest radiology

    Science.gov (United States)

    Jacobs, J.; Zanca, F.; Verschakelen, J.; Marchal, G.; Bosmans, H.

    2009-02-01

    Until recently, the specifications of medical grade monochrome LCD monitors outperformed those of color LCD monitors. New generations of color LCD monitors, however, show specifications that are in many respects similar to those of monochrome monitors typically used in diagnostic workstations. The aim of present study was to evaluate the impact of different medical grade monitors in terms of detection of simulated lung nodules in chest x-ray images. Specifically, we wanted to compare a new medical grade color monitor (Barco Coronis 6MP color) to a medical grade grayscale monitor (Barco Coronis 3MP monochrome) and a consumer color monitor (Philips 200VW 1.7MP color) by means of an observer performance experiment. Using the free-response acquisition data paradigm, seven radiologists were asked to detect and locate lung nodules (170 in total), simulated in half of the 200 chest X-ray images used in the experiment. The jackknife free-response receiver operating characteristic (JAFROC) analysis of the data showed a statistically significant difference between at least two monitors, F-value=3.77 and p-value =0.0481. The different Figure of Merit values were 0.727, 0.723 and 0.697 for the new color LCD monitor, the medical grade monitor and the consumer color monitor respectively. There was no difference between the needed reading times but there was a difference between the mean calculated Euclidian distances between the position marked by the observers and the center of the simulated nodule, indicating a better accuracy with both medical grade monitors. Present data suggests that the new generation of medical grade color monitors could be used as diagnostic workstations.

  1. LEDA BEAM DIAGNOSTICS INSTRUMENTATION: BEAM POSITION MONITORS

    International Nuclear Information System (INIS)

    Barr, D.

    2000-01-01

    The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7-MeV and current of 100-mA operating in either a pulsed or cw mode. Of key importance to the commissioning and operations effort is the Beam Position Monitor system (BPM). The LEDA BPM system uses five micro-stripline beam position monitors processed by log ratio processing electronics with data acquisition via a series of custom TMS32OC40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of the system, the log ratio processing, and the system calibration technique. This paper will also cover the DSP system operations and their interaction with the main accelerator control system

  2. Comparative analysis of diagnostic performance, feasibility and cost of different test-methods for thyroid nodules with indeterminate cytology.

    Science.gov (United States)

    Sciacchitano, Salvatore; Lavra, Luca; Ulivieri, Alessandra; Magi, Fiorenza; De Francesco, Gian Paolo; Bellotti, Carlo; Salehi, Leila B; Trovato, Maria; Drago, Carlo; Bartolazzi, Armando

    2017-07-25

    Since it is impossible to recognize malignancy at fine needle aspiration (FNA) cytology in indeterminate thyroid nodules, surgery is recommended for all of them. However, cancer rate at final histology is blood assay.We performed systematic reviews and meta-analyses to compare their features, feasibility, diagnostic performance and cost. GEC, GEC+BRAF, M/F panel+miRNA GEC and M/F panel by NGS were the best in ruling-out malignancy (sensitivity = 90%, 89%, 89% and 90% respectively). BRAF and M/F panel alone and by NGS were the best in ruling-in malignancy (specificity = 100%, 93% and 93%). The M/F by NGS showed the highest accuracy (92%) and BRAF the highest diagnostic odds ratio (DOR) (247). GAL-3-ICC performed well as rule-out (sensitivity = 83%) and rule-in test (specificity = 85%), with good accuracy (84%) and high DOR (27) and is one of the cheapest (113 USD) and easiest one to be performed in different clinical settings.In conclusion, the more accurate molecular-based test-methods are still expensive and restricted to few, highly specialized and centralized laboratories. GAL-3-ICC, although limited by some false negatives, represents the most suitable screening test-method to be applied on a large-scale basis in the diagnostic algorithm of indeterminate thyroid lesions.

  3. Social anxiety disorder diagnostic criteria perform equally across age, comorbid diagnosis, and performance/interaction subtypes.

    Science.gov (United States)

    Crome, Erica; Baillie, Andrew

    2015-01-01

    The prevalence of social anxiety disorder (SAD) is frequently higher in younger age groups and people with other anxiety or mood disorders; however, it is unclear whether these groups have a higher risk for developing SAD or are simply more likely to endorse diagnostic criteria than other people with similar levels of social anxiety. Explicitly testing the assumption all people respond to structured diagnostic interviews in comparable ways (measurement invariance) is essential in ensuring systematic response biases do not create spurious group differences. This research aims to systematically test whether age, comorbidity status, or types of social fears affect responses to a structured diagnostic interview. Responses from 1755 participants in a large-scale survey of mental health in Australia screening into the social phobia/SAD section of the Composite International Diagnostic Interview were used. Three series of multigroup confirmatory factor analyses for categorical data systematically tested for increasingly strict levels of measurement invariance. Overall, patterns of responding to diagnostic criteria were comparable across the groups, supporting assumptions of measurement invariance. Establishment of invariance supports the interpretation of differences between age, comorbidity status, and types of social situations feared as genuine differences in experience as opposed to measurement biases.

  4. Diagnostic mirrors for ITER: A material choice and the impact of erosion and deposition on their performance

    International Nuclear Information System (INIS)

    Litnovsky, A.; Wienhold, P.; Philipps, V.; Sergienko, G.; Schmitz, O.; Kirschner, A.; Kreter, A.; Droste, S.; Samm, U.; Mertens, Ph.; Donne, A.H.; Rudakov, D.; Allen, S.; Boivin, R.; McLean, A.; Stangeby, P.; West, W.; Wong, C.; Lipa, M.; Schunke, B.; De Temmerman, G.; Pitts, R.; Costley, A.; Voitsenya, V.; Vukolov, K.; Oelhafen, P.; Rubel, M.; Romanyuk, A.

    2007-01-01

    Metal mirrors will be implemented in about half of the ITER diagnostics. Mirrors in ITER will have to withstand radiation loads, erosion by charge-exchange neutrals, deposition of impurities, particle implantation and neutron irradiation. It is believed that the optical properties of diagnostic mirrors will be primarily influenced by erosion and deposition. A solution is needed for optimal performance of mirrors in ITER throughout the entire lifetime of the machine. A multi-machine research on diagnostic mirrors is currently underway in fusion facilities at several institutions and laboratories worldwide. Among others, dedicated investigations of ITER-candidate mirror materials are ongoing in Tore-Supra, TEXTOR, DIII-D, TCV, T-10 and JET. Laboratory studies are underway at IPP Kharkov (Ukraine), Kurchatov Institute (Russia) and the University of Basel (Switzerland). An overview of current research on diagnostic mirrors along with an outlook on future investigations is the subject of this paper

  5. Diagnostic performance of major depression disorder case-finding instruments used among mothers of young children in the United States: A systematic review.

    Science.gov (United States)

    Owora, Arthur H; Carabin, Hélène; Reese, Jessica; Garwe, Tabitha

    2016-09-01

    Growing recognition of the interrelated negative outcomes associated with major depression disorder (MDD) among mothers and their children has led to renewed public health interest in the early identification and treatment of maternal MDD. Healthcare providers, however, remain unsure of the validity of existing case-finding instruments. We conducted a systematic review to identify the most valid maternal MDD case-finding instrument used in the United States. We identified articles reporting the sensitivity and specificity of MDD case-finding instruments based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) by systematically searching through three electronic bibliographic databases, PubMed, PsycINFO, and EMBASE, from 1994 to 2014. Study eligibility and quality were evaluated using the Standards for the Reporting of Diagnostic Accuracy studies and Quality Assessment of Diagnostic Accuracy Studies guidelines respectively. Overall, we retrieved 996 unduplicated articles and selected 74 for full-text review. Of these, 14 articles examining 21 different instruments were included in the systematic review. The 10 item Edinburgh Postnatal Depression Scale and Postpartum Depression Screening Scale had the most stable (lowest variation) and highest diagnostic performance during the antepartum and postpartum periods (sensitivity range: 0.63-0.94 and 0.67-0.95; specificity range: 0.83-0.98 and 0.68-0.97 respectively). Greater variation in diagnostic performance was observed among studies with higher MDD prevalence. Factors that explain greater variation in instrument diagnostic performance in study populations with higher MDD prevalence were not examined. Findings suggest that the diagnostic performance of maternal MDD case-finding instruments is peripartum period-specific. Published by Elsevier B.V.

  6. Evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia.

    Science.gov (United States)

    Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh

    2015-12-26

    Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.

  7. Video profile monitor diagnostic system for GTA

    International Nuclear Information System (INIS)

    Sandovil, D.P.; Garcia, R.C.; Gilpatrick, J.D.; Johnson, K.F.; Shinas, M.A.; Wright, R.; Yuan, V.; Zander, M.E.

    1992-01-01

    This paper describes a video diagnostic system used to measure the beam profile and position of the Ground Test Accelerator 2.5 MeV H - ion beam as it exits the intermediate matching section. Inelastic collisions between H - ions and residual nitrogen in the vacuum chamber cause the nitrogen to fluoresce. The resulting light is captured through transport optics by an intensified CCD camera and is digitized. Real-time beam profile images are displayed and stored for detailed analysis. Analyzed data showing resolutions for both position and profile measurements will also be presented. (Author) 5 refs., 7 figs

  8. Diagnostic performance of sonoelastographic Tsukuba score and strain ratio in evaluation of breast masses

    Directory of Open Access Journals (Sweden)

    Mahmoud Abd Elaziz Dawood

    2018-03-01

    Full Text Available The aim of this prospective study was to evaluate the diagnostic performance of the use of strain index ratio by sonoelastography to differentiate between benign and malignant breast lesions. Patients & Methods: This prospective study including 40 females, complaining of breast masses which were suspicious to be malignant on clinical examination. All patients were submitted to B-mode Ultrasound and sonoelastography. Biopsy as a gold standard and pathological study were done for all breast lesions. Results: US examination of every mass was done and categorized according to BI-RADS categories according to ACR2013, according to US lexicon. Sonoelastography examination with Lesions classification was performed on the basis of a 5-point scoring method proposed by Tsukuba elasticity score. Then measurements of strain ratio were done. Statistical analysis of combination of the three methods was sensitivity of 96.7%, specificity of 100% when we use cut off value of 3–4 in elastography score and ≤3 cut off value of strain ratio. Conclusion: The combined use of strain ratio with Tsukuba score and BI-RADS categorization increased the diagnostic performance in differentiation between benign and malignant breast lesions. Keywords: Elastography, Breast masses, Strain ratio, Ultrasound, BI-RADS classification, Tsukuba score

  9. Diagnostic performance of Contrast-enhanced CT in Pyrrolizidine Alkaloids-induced Hepatic Sinusoidal Obstructive Syndrome

    Science.gov (United States)

    Kan, Xuefeng; Ye, Jin; Rong, Xinxin; Lu, Zhiwen; Li, Xin; Wang, Yong; Yang, Ling; Xu, Keshu; Song, Yuhu; Hou, Xiaohua

    2016-01-01

    Hepatic sinusoidal obstruction syndrome (HSOS) can be caused by pyrrolizidine alkaloids(PAs)-containing herbals. Since PAs exposure is obscure and clinical presentation of HSOS is unspecific, it is challenge to establish the diagnosis of PAs-induced HSOS. Gynura segetum is one of the most wide-use herbals containing PAs. The aim of our study is to describe the features of contrast-enhanced computed tomography (CT) in gynura segetum-induced HSOS, and then determine diagnostic performance of radiological signs. We retrospectively analyzed medical records and CT images of HSOS patients (71 cases) and the controls (222 cases) enrolled from January 1, 2008, to Oct 31, 2015. The common findings of contrast CT in PAs-induced HSOS included: ascites (100%), hepatomegaly (78.87%), gallbladder wall thickening (86.96%), pleural effusion (70.42%), hepatic vein narrowing (87.32%), patchy liver enhancement (92.96%), and heterogeneous hypoattenuation (100%); of these signs, patchy enhancement and heterogeneous hypoattenuation were valuable features. Then, the result of diagnostic performance demonstrated that contrast CT possessed better performance in diagnosing PAs-induced HSOS compared with various parameters of Seattle criteria. In conclusion, the patients with PAs-induced HSOS display distinct radiologic features at CT-scan, which reveals that contrast-enhanced CT provides an effective noninvasive method for diagnosing PAs-induced HSOS. PMID:27897243

  10. Occupational radiation doses among diagnostic radiation workers in South Korea, 1996-2006

    International Nuclear Information System (INIS)

    Lee, W. J.; Cha, E. S.; Ha, M.; Jin, Y. W.; Hwang, S. S.; Kong, K. A.; Lee, S. W.; Lee, H. K.; Lee, K. Y.; Kim, H. J.

    2009-01-01

    This study details the distribution and trends of doses of occupational radiation among diagnostic radiation workers by using the national dose registry between 1996 and 2006 by the Korea Food and Drug Administration. Dose measurements were collected quarterly by the use of thermoluminescent dosemeter personal monitors. A total of 61 732 workers were monitored, including 18 376 radiologic technologists (30%), 13 762 physicians (22%), 9858 dentists (16%) and 6114 dental hygienists (9.9%). The average annual effective doses of all monitored workers decreased from 1.75 to 0.80 mSv over the study period. Among all diagnostic radiation workers, radiologic technologists received both the highest effective and collective doses. Male radiologic technologists aged 30-49 y composed the majority of workers receiving more than 5 mSv in a quarter. More intensive monitoring of occupational radiation exposure and investigation into its health effects on diagnostic radiation workers are required in South Korea. (authors)

  11. Performance Monitoring for Nuclear Safety Related Instrumentation at PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Mohd Sabri Minhat

    2015-01-01

    The Reactor TRIGA PUSPATI (RTP) at Malaysia Nuclear Agency is a TRIGA Mark II type reactor and pool type cooled by natural circulation of light water. This paper describe on performance monitoring for nuclear safety related instrumentation in TRIGA PUSPATI Reactor (RTP) of based on various parameter of reactor safety instrument channel such as log power, linear power, Fuel temperature, coolant temperature will take into consideration. Methodology of performance on estimation and monitoring is to evaluate and analysis of reactor parameters which is important of reactor safety and control. And also to estimate power measurement, differential of log and linear power and fuel temperature during reactor start-up, operation and shutdown .This study also focus on neutron power fluctuation from fission chamber during reactor start-up and operation. This work will present result of performance monitoring from RTP which indicated the safety parameter identification and initiate safety action on crossing the threshold set point trip. Conclude that performance of nuclear safety related instrumentation will improved the reactor control and safety parameter during reactor start-up, operation and shutdown. (author)

  12. Magnetic resonance imaging and magnetic resonance arthrography of the shoulder: dependence on the level of training of the performing radiologist for diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Theodoropoulos, John S. [University of Toronto, Division of Orthopaedics, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); Andreisek, Gustav [University of Toronto, Department of Medical Imaging, Mount Sinai Hospital and the University Health Network, Toronto, ON (Canada); University Hospital Zuerich, Institute for Diagnostic Radiology, Zuerich (Switzerland); Harvey, Edward J. [McGill University, Division of Orthopaedics, MUHC - Montreal General Hospital, Montreal, Quebec (Canada); Wolin, Preston [Center for Athletic Medicine, Chicago, IL (United States)

    2010-07-15

    Discrepancies were identified between magnetic resonance (MR) imaging and clinical findings in patients who had MR imaging examinations evaluated by community-based general radiologists. The purpose of this study was to evaluate the diagnostic performance of MR imaging examinations of the shoulder with regard to the training level of the performing radiologist. A review of patient charts identified 238 patients (male/female, 175/63; mean age, 40.4 years) in whom 250 arthroscopies were performed and who underwent MR imaging or direct MR arthrography in either a community-based or hospital-based institution prior to surgery. All MR imaging and surgical reports were reviewed and the diagnostic performance for the detection of labral, rotator cuff, biceps, and Hill-Sachs lesions was determined. Kappa and Student's t test analyses were performed in a subset of cases in which initial community-based MR images were re-evaluated by hospital-based musculoskeletal radiologists, to determine the interobserver agreement and any differences in image interpretation. The diagnostic performance of community-based general radiologists was lower than that of hospital-based sub-specialized musculoskeletal radiologists. A sub-analysis of re-evaluated cases showed that musculoskeletal radiologists performed better. {kappa} values were 0.208, 0.396, 0.376, and 0.788 for labral, rotator cuff, biceps, and Hill-Sachs lesions (t test statistics: p =<0.001, 0.004, 0.019, and 0.235). Our results indicate that the diagnostic performance of MR imaging and MR arthrography of the shoulder depends on the training level of the performing radiologist, with sub-specialized musculoskeletal radiologists having a better diagnostic performance than general radiologists. (orig.)

  13. The indication area of a diagnostic test. Part I--discounting gain and loss in diagnostic certainty

    NARCIS (Netherlands)

    Stalpers, Lukas J. A.; Nelemans, Patty J.; Geurts, Sandra M. E.; Jansen, Erik; de Boer, Peter; Verbeek, André L. M.

    2015-01-01

    Test performance is conventionally expressed by gain in diagnostic certainty. We propose net diagnostic gain and indication area as more appropriate measures of test performance; then, the loss in certainty due to misclassification and the information of "no test" would be performed are taken into

  14. Comparative diagnostic performance of multidetector computed tomography and MRI for characterization of pancreatic cystic lesions

    International Nuclear Information System (INIS)

    Moon, Sung Min; Shin, Sang Soo; Park, Jin Gyoon; Jeong, Yong Yeon

    2015-01-01

    To compare the diagnostic performance of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in characterization of pancreatic cystic lesions. We conducted a retrospective study on 34 patients with histopathologically proven cystic pancreatic lesions who underwent both preoperative MDCT and MRI. CT and MRI were independently evaluated for differentiating mucinous vs. non-mucinous lesions, differentiating aggressive vs. non-aggressive lesion, analyzing morphological features, and evaluating specific leading diagnoses. Sensitivity, specificity, and accuracy were determined. Competency assessment of lesional morphology analysis was performed using the kappa values of the 2 tests. The sensitivity, specificity, and accuracy of MRI for differentiating mucinous vs. non-mucinous lesions were higher than CT (p = 0.03). For differentiating aggressiveness, the sensitivity of MRI was better than CT, but the specificity of CT was better than MRI. In evaluation of morphologic features, MRI showed better performance in characterization of septa and wall. Otherwise, the 2 modalities showed similarly good performance. MRI was better than CT in determining a specific diagnosis (58.8% vs. 47.2%, respectively). CT and MRI are reasonable diagnostic methods for characterization of pancreatic cystic lesions. However, MRI enables more confident assessment than CT in differentiating mucinous vs. non-mucinous lesions and characterization of the septa and wall

  15. Beam diagnostic elements at the Laboratorio Nazionale del Sud

    International Nuclear Information System (INIS)

    Calabretta, L.; Cuttone, G.; Raia, G.

    1988-01-01

    The choice of the main beam diagnostic elements at the LNS has to take into account the future installation of the Milan Superconducting Cyclotron and its matching to the MP tandem in Catania. A diagnostic box, consisting of a home-made beam profile monitor, a pair of slits and a Faraday cup, has been designed according to these particular requirements. The main features of these diagnostic elements and preliminary results are described. (orig.)

  16. 22 CFR 226.51 - Monitoring and reporting program performance.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Monitoring and reporting program performance. 226.51 Section 226.51 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF... more frequently than quarterly or, less frequently than annually. Annual reports shall be due 90...

  17. Malignant renal cysts: Diagnostic performance and strong predictors at MDCT

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Kim, Jeong Kon; Cho, Kyoung-Sik; Min, Gyeong-Eun; Ahn, Han-Jong

    2010-01-01

    Background: Utilization of multidetector-row CT (MDCT) is anticipated to improve the diagnostic accuracy and reliability for determining malignant cysts. Purpose: To assess the diagnostic accuracy, interobserver agreement, benefit of consensus reading, and strong predictors of malignancy in determining malignant cystic renal masses at MDCT. Material and Methods: Two radiologists independently rated the probability of malignancy at MDCT in 72 benign and 53 malignant cysts. The accuracy and interobserver agreement for determining malignant cysts were evaluated. The strong predictors of malignancy were determined, and in patients with interobserver disagreement for determining malignant cysts, consensus readings were performed. Results: Az value of the two readers was 0.905-0.936 and the sensitivity and specificity were 85-89% and 83-93%, respectively. The overall interobserver agreement for determining the malignant cyst was good as the κ value was 0.696 (% agreement, 61% (76/125)). Thickened irregular wall, thickened irregular septa, and enhancing soft tissue component were strong predictors for malignancy with both readers. In the 17 patients with interobserver disagreement for determining malignant cysts, the sensitivity was improved from 38-63% to 89% by the consensus reading. Conclusion: At MDCT, some false negative decisions for determining malignant cysts can be corrected by consensus reading, and thickened irregular septa, thickened irregular wall, and enhancing soft tissue component are the strong predictors of malignant cysts

  18. Prevalence and diagnostic performance of computed tomography angiography spot sign for intracerebral hematoma expansion depend on scan timing

    Energy Technology Data Exchange (ETDEWEB)

    Tsukabe, Akio; Watanabe, Yoshiyuki; Tanaka, Hisashi; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Yoshiya, Kazuhisa; Shimazu, Takeshi [Osaka University Graduate School of Medicine, Department of Traumatology and Acute Critical Medicine, Suita, Osaka (Japan)

    2014-12-15

    The computed tomography angiography (CTA) spot sign correlates with intracerebral hemorrhage (ICH) expansion; however, various diagnostic performances for hematoma expansion, especially in sensitivity, have been reported. We aimed to assess the impact of scan timing of CTA on the diagnostic performance of the CTA spot sign for ICH expansion in two different arterial phases within patients. Eighty-three consecutive patients with primary ICH who received two sequential CTAs were recruited. Two neuroradiologists reviewed CTAs for CTA spot signs, while one reviewed initial and follow-up non-contrast CT for measuring ICH volume. The time interval between two phases was then calculated, and the diagnostic performance of CTA spot sign in each phase was evaluated. CTA spot signs were observed in 20/83 (24.1 %) patients in the early phase and 44/83 (53.0 %) patients in the late phase. The mean time interval between the two phases was 12.7 s. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for hematoma progression of CTA spot sign were 48.1, 87.5, 65.0, 77.8, and 74.7 %, respectively, in early phase and 92.6, 66.1, 56.8, 94.9, and 74.7 %, respectively, in late phase. The CTA spot sign was significantly associated with ICH expansion in early (P < 0.001) and late (P < 0.00001) phases (Pearson's chi-square test). A mere 10-s difference in scan timing could make a difference on prevalence and diagnostic performance of the CTA spot sign, suggesting a need for the standardization of the CTA protocol to generalize the approach for effective clinical application. (orig.)

  19. Complete Web Monitoring Watching Performance, Users, and Communities

    CERN Document Server

    Croll, Alistair

    2009-01-01

    Complete Web Monitoring demonstrates how to measure every aspect of your web presence -- including analytics, backend performance, usability, communities, customer feedback, and competitive analysis -- whether you're running an e-commerce site, a community, a media property, or a Software-as-a-Service company. This book's concrete examples, clear explanations, and practical recommendations make it essential for anyone who runs a website.

  20. A clinicopathological study of various oral cancer diagnostic techniques

    Directory of Open Access Journals (Sweden)

    G Ulaganathan

    2017-01-01

    Full Text Available Oral cancer is one of the most commonly occurring malignant tumors in the head and neck regions with high incident rate and mortality rate in the developed countries than in the developing countries. Generally, the survival rate of cancer patients may increase when diagnosed at early stage, followed by prompt treatment and therapy. Recently, cancer diagnosis and therapy design for a specific cancer patient have been performed with the advanced computer-aided techniques. The responses of the cancer therapy could be continuously monitored to ensure the effectiveness of the treatment process that hardly requires diagnostic result as quick as possible to improve the quality and patient care. This paper gives an overview of oral cancer occurrence, different types, and various diagnostic techniques. In addition, a brief introduction is given to various stages of immunoanalysis including tissue image preparation, whole slide imaging, and microscopic image analysis.

  1. MR arthrography in calcific tendinitis of the shoulder: diagnostic performance and pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Zubler, Christoph; Mengiardi, Bernard; Schmid, Marius R.; Hodler, Juerg; Pfirrmann, Christian W.A. [University Hospital Balgrist, Radiology, Zurich (Switzerland); Jost, Bernhard [University Hospital Balgrist, Orthopedic Surgery, Zurich (Switzerland)

    2007-06-15

    The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiographs. (orig.)

  2. MR arthrography in calcific tendinitis of the shoulder: diagnostic performance and pitfalls

    International Nuclear Information System (INIS)

    Zubler, Christoph; Mengiardi, Bernard; Schmid, Marius R.; Hodler, Juerg; Pfirrmann, Christian W.A.; Jost, Bernhard

    2007-01-01

    The purpose was to assess the diagnostic performance of MR arthrography to diagnose calcific tendinitis of the shoulder and to assess the reasons for diagnostic errors. Standard MR arthrograms of 22 patients with calcific tendinitis and 61 controls were retrospectively analyzed by two independent and blinded radiologists. All cases were consecutively collected from a database. Conventional radiographs were available in all cases serving as gold standard. The supraspinatus was involved in 16, the infraspinatus in four and the subscapularis in two patients. All diagnostic errors were analyzed by two additional readers. Reader 1 correctly detected 12 of the 22 shoulders with and 42 of the 61 shoulders without calcific tendinitis (sensitivity 0.55, specificity 0.66). The corresponding values for reader 2 were 13 of 22 and 40 of 61 cases (sensitivity 0.59, specificity 0.69). Inter-rater agreement (kappa-value) was 0.42. Small size of the calcific deposits and isointensity compared to the surrounding tissue were the most important reasons for false negative results. Normal hypointense areas within the supraspinatus tendon substance and attachment were the main reason for false positive results. In conclusion, MR arthrography is insufficient in the diagnosis of calcific tendinitis. Normal hypointense parts of the rotator cuff may mimic calcific deposits and calcifications may not be detected when they are isointense compared to the rotator cuff. Therefore, MR imaging should not be interpreted without corresponding radiographs. (orig.)

  3. Regional Diagnostic Reference Levels and Collective Effective Doses from Computed Tomography (CT) Scanners in India

    International Nuclear Information System (INIS)

    Livingstone, R.S.; Dinakaran, P.M.

    2011-01-01

    Diagnostic examinations performed using computed tomography (CT) are on the increase, and the use of this modality needs to be monitored periodically. The aim of this study was to formulate regional diagnostic reference levels (DRLs) and assess collective effective doses from CT scanners in Tamil Nadu, India. In-site CT dose measurements were performed for 127 CT scanners in Tamil Nadu as a part of the Atomic Energy Regulatory Board (AERB) funded project for a period of two years. Regional DRLs were formulated at third quartile level for three CT protocols such as thorax, abdomen and pelvis and were found to be 557 mGy.cm, 521 mGy.cm and 294 mGy.cm, respectively. The collective effective dose in Tamil Nadu was found to be 14.93 man Sv per day. (author)

  4. Performance Management and Monitoring of Internal Audit for the Public Sector in Romania

    Directory of Open Access Journals (Sweden)

    Elena Doina Dascălu

    2016-08-01

    Full Text Available Performance management is an on-going process, which has an essential component part, performance measurement, which involves the identification, supervision and communication of performance results, through the relation to a set of performance indicators. Based on the assessment results, corrective measures are established to ensure attainment of targeted results, offering a feedback, essential for the decision grounding enhancement, at all levels: strategic, operational or individual. As concerns performance management in public institutions in Romania, The Code on managerial internal control provides a hierarchy type model, in the framework of which, the head of the public entity, which is on the first level, needs to provide for performance monitoring for each objective and activity, through the intermediary of relevant quantitative and qualitative indicators, including referring to economy, efficiency, and effectiveness. Given the importance of the internal audit in the process of performance management, identifying solutions for continuous improvement of the public internal audit was subject to a study that was based on questioning public sector auditors on how to monitor the performance of public internal audit activity. Considering issues arising, the article proposes a series of directions for improving the monitoring of the performance of public internal audit activity in the public sector.

  5. Evaluation of the RSG-GAS Alpha-Beta Aerosol Contaminant Monitor Performance Under Reactor Operation Condition

    International Nuclear Information System (INIS)

    Hartoyo, Unggul; Setiawanto, Anto; Sumarno, Yulius

    2000-01-01

    Analysis to evaluate the RSG-GAS alpha-beta aerosol contaminant monitor performance was done. The high potential radiation working area such as in RSG-GAS is important to monitored for personal safety. Further it is necessary to assure that the system monitor is reliable enough under normal conditions as well as emergency condition. The method uses in this analysis are monitoring and comparing with the standard source. The standard course indicator and panel in main control room indicate that the result is 1 x 110 exp 9 Ci/m exp 3. Based on data monitor observation, the RSG-GAS alpha-beta aerosol contaminant monitor system under reactor operation condition has a good enough performance

  6. Mobile phone-based biosensing: An emerging "diagnostic and communication" technology.

    Science.gov (United States)

    Quesada-González, Daniel; Merkoçi, Arben

    2017-06-15

    In this review we discuss recent developments on the use of mobile phones and similar devices for biosensing applications in which diagnostics and communications are coupled. Owing to the capabilities of mobile phones (their cameras, connectivity, portability, etc.) and to advances in biosensing, the coupling of these two technologies is enabling portable and user-friendly analytical devices. Any user can now perform quick, robust and easy (bio)assays anywhere and at any time. Among the most widely reported of such devices are paper-based platforms. Herein we provide an overview of a broad range of biosensing possibilities, from optical to electrochemical measurements; explore the various reported designs for adapters; and consider future opportunities for this technology in fields such as health diagnostics, safety & security, and environment monitoring. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. All-polymer biosensor for label-free point of care diagnostics

    DEFF Research Database (Denmark)

    Dapra, Johannes

    2013-01-01

    without the need for a specialised laboratory. Other fields of application are for example health care projects in developing countries where access to modern high-throughput facilities is often impossible or sectors not related to the medical field, like environmental monitoring or food safety. The aim......Personalised medicine and diagnostics is a rapidly growing field of research and general interest. Important tools for individual patient care are so called point-of-care devices. These typically simple and inexpensive instruments allow the untrained user to perform simple diagnostic analyses...... of this PhD project was to develop a modular platform based on electrochemical impedimetric sensing. This device can easily be modified by changing the biological receptors and therefore offers a broad range of possible applications. To keep the costs and the environmental footprint low the entire biosensor...

  8. Advanced Performance Modeling with Combined Passive and Active Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Dovrolis, Constantine [Georgia Inst. of Technology, Atlanta, GA (United States); Sim, Alex [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-04-15

    To improve the efficiency of resource utilization and scheduling of scientific data transfers on high-speed networks, the "Advanced Performance Modeling with combined passive and active monitoring" (APM) project investigates and models a general-purpose, reusable and expandable network performance estimation framework. The predictive estimation model and the framework will be helpful in optimizing the performance and utilization of networks as well as sharing resources with predictable performance for scientific collaborations, especially in data intensive applications. Our prediction model utilizes historical network performance information from various network activity logs as well as live streaming measurements from network peering devices. Historical network performance information is used without putting extra load on the resources by active measurement collection. Performance measurements collected by active probing is used judiciously for improving the accuracy of predictions.

  9. A framework for cognitive monitoring using computer game interactions.

    Science.gov (United States)

    Jimison, Holly B; Pavel, Misha; Bissell, Payton; McKanna, James

    2007-01-01

    Many countries are faced with a rapidly increasing economic and social challenge of caring for their elderly population. Cognitive issues are at the forefront of the list of concerns. People over the age of 75 are at risk for medically related cognitive decline and confusion, and the early detection of cognitive problems would allow for more effective clinical intervention. However, standard cognitive assessments are not diagnostically sensitive and are performed infrequently. To address these issues, we have developed a set of adaptive computer games to monitor cognitive performance in a home environment. Assessment algorithms for various aspects of cognition are embedded in the games. The monitoring of these metrics allows us to detect within subject trends over time, providing a method for the early detection of cognitive decline. In addition, the real-time information on cognitive state is used to adapt the user interface to the needs of the individual user. In this paper we describe the software architecture and methodology for monitoring cognitive performance using data from natural computer interactions in a home setting.

  10. Quality control of the interpretation monitors of digital radiological images

    International Nuclear Information System (INIS)

    Favero, Mariana S.; Goulart, Adriano Oliveira S.

    2016-01-01

    The performance monitors has great importance in image quality of digital radiographic systems. In environments without films, it became necessary to implement acceptance testing and quality control monitors used for interpretation of medical images. The monitors dedicated to radiodiagnostic should provide information that represent slight differences in x-ray attenuation or minor differences in some anatomical region of interest. This should also result in small differences in luminance of an image represented. Factors affecting the quality of medical imaging are contrast, noise, resolution, artifacts and distortions. Therefore, a monitor must have specific characteristics, making it possible for the observer to carry out an assessment that leads to better diagnosis. Based on the need to evaluate diagnostic monitors in various radiological applications, this paper presents a summary for implementation and standardization of tests that are recommended by the publication AAPM Report 03. (author)

  11. Serumferritin - diagnostic relevance and clinical usefulness

    Energy Technology Data Exchange (ETDEWEB)

    Linkesch, W [Vienna Univ. (Austria). 2. Medizinische Klinik

    1984-01-01

    The introduction of a WHO Standard for serumferritin effected a standardisation of different methods, improving quality and security for clinical routine diagnostic purposes. Therefore the clinical evaluation of serumferritin gained even more importance. For evaluation of iron stores of children, pregnant women, population studies, patients on hemodialysis or patients with rheumatoid arthritis low serumferritin values give safe results. In addition serumferritin is of clinical usefulness in monitoring therapy of both iron deficiency and iron overload. Evaluating a single serumferritin value one should consider the total clinical situation of the patient. As some tumors can produce and secrete serumferritin, e.g. acute myeloblastic leukemia, germ cell tumors, malignant melanoma, serumferritin might be helpful in monitoring the malignant disease. The ongoing characterization of tissue isoferritin, especially acidic isoferritin, may eventually lead to a clinically significant diagnostic marker of neoplasia.

  12. Serumferritin - diagnostic relevance and clinical usefulness

    International Nuclear Information System (INIS)

    Linkesch, W.

    1984-01-01

    The introduction of a WHO Standard for serumferritin effected a standardisation of different methods, improving quality and security for clinical routine diagnostic purposes. Therefore the clinical evaluation of serumferritin gained even more importance. For evaluation of iron stores of children, pregnant women, population studies, patients on hemodialysis or patients with rheumatoid arthritis low serumferritin values give safe results. In addition serumferritin is of clinical usefulness in monitoring therapy of both iron deficiency and iron overload. Evaluating a single serumferritin value on should consider the total clinical situation of the patient. As some tumors can produce and secrete serumferritin, e. g. acute myeloblastic leukemia, germ cell tumors, malignant melanoma, serumferritin might be helpful in monitoring the malignant disease. The ongoing characterization of tissue isoferritin, especially acidic isoferritin, may eventually lead to a clinically significant diagnostic marker of neoplasia. (Author)

  13. Diagnostic Performance of Self-Assessment for Constipation in Patients With Long-Term Opioid Treatment.

    Science.gov (United States)

    Tafelski, Sascha; Bellin, Felicitas; Denke, Claudia; Beutlhauser, Torsten; Fritzsche, Thomas; West, Christina; Schäfer, Michael

    2015-12-01

    Constipation is a prevalent comorbidity affecting ∼50% of patients with long-term opioid therapy. In clinical routine different diagnostic instruments are in use to identify patients under risk. The aim of this study was to assess the diagnostic performance of an 11-item Likert scale for constipation used as a self-assessment in opioid-treated patients. This trial was conducted as a retrospective cohort study in Berlin, Germany. Patients with long-term opioid therapy treated in 2 university-affiliated outpatient pain facilities at the Charité hospital were included from January 2013 to August 2013. Constipation was rated in a self-assessment using a numeric rating scale from 0 to 10 (Con-NRS) and compared with results from a structured assessment based on ROME-III criteria. Altogether, 171 patients were included. Incidence of constipation was 49% of patients. The receiver-operating characteristic of Con-NRS achieved an area under the curve of 0.814 (AUC 95% confidence interval 0.748-0.880, P < 0.001). Con-NRS ≥ 1 achieved sensitivity and specificity of 79.7% and 77.2%, respectively. The positive predictive value and the negative predictive value were 70.3% and 81.6%, respectively. Overall diagnostic performance of a concise 11-item Likert scale for constipation was moderate. Although patients with long-term opioid therapy are familiar with numeric rating scales, a significant number of patients with constipation were not identified. The instrument may be additionally useful to facilitate individualized therapeutic decision making and to control therapeutic success when measured repetitively.

  14. Frequency of chest pain in primary care, diagnostic tests performed and final diagnoses.

    Science.gov (United States)

    Hoorweg, Beatrijs Bn; Willemsen, Robert Ta; Cleef, Lotte E; Boogaerts, Tom; Buntinx, Frank; Glatz, Jan Fc; Dinant, Geert Jan

    2017-11-01

    Observational study of patients with chest pain in primary care: determination of incidence, referral rate, diagnostic tests and (agreement between) working and final diagnoses. 118 general practitioners (GPs) in the Netherlands and Belgium recorded all patient contacts during  2weeks. Furthermore, patients presenting with chest pain were registered extensively. A follow-up form was filled in after 30 days. 22 294 patient contacts were registered. In 281 (1.26%), chest pain was a reason for consulting the GP (mean age for men 54.4/women 53 years). In this cohort of 281 patients, in 38.1% of patients, acute coronary syndrome (ACS) was suspected at least temporarily during consultation, 40.2% of patients were referred to secondary care and 512 diagnostic tests were performed by GPs and consulted specialists. Musculoskeletal pain was the most frequent working (26.1%) and final diagnoses (33.1%). Potentially life-threatening diseases as final diagnosis (such as myocardial infarction) accounted for 8.4% of all chest pain cases. In 23.1% of cases, a major difference between working and final diagnoses was found, in 0.7% a severe disease was initially missed by the GP. Chest pain was present in 281 patients (1.26% of all consultations). Final diagnoses were mostly non-life-threatening. Nevertheless, in 8.4% of patients with chest pain, life-threatening underlying causes were identified. This seems reflected in the magnitude and wide variety of diagnostic tests performed in these patients by GPs and specialists, in the (safe) overestimation of life-threatening diseases by GPs at initial assessment and in the high referral rate we found. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Volume perfusion CT imaging of cerebral vasospasm: diagnostic performance of different perfusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Ahmed E. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Radiology, Tuebingen (Germany); Afat, Saif; Nikoubashman, Omid; Mueller, Marguerite; Wiesmann, Martin; Brockmann, Carolin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Schubert, Gerrit Alexander [RWTH Aachen University, Department of Neurosurgery, Aachen (Germany); Bier, Georg [Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Brockmann, Marc A. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); University Hospital Mainz, Department of Neuroradiology, Mainz (Germany)

    2016-08-15

    In this study, we aimed to evaluate the diagnostic performance of different volume perfusion CT (VPCT) maps regarding the detection of cerebral vasospasm compared to angiographic findings. Forty-one datasets of 26 patients (57.5 ± 10.8 years, 18 F) with subarachnoid hemorrhage and suspected cerebral vasospasm, who underwent VPCT and angiography within 6 h, were included. Two neuroradiologists independently evaluated the presence and severity of vasospasm on perfusion maps on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting <50 %, 2 - vasospasm affecting >50 % of vascular territory). A third neuroradiologist independently assessed angiography for the presence and severity of vasospasm on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting < 50 %, 2 - vasospasm affecting > 50 % of vessel diameter). Perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to drain (TTD) were evaluated regarding diagnostic accuracy for cerebral vasospasm with angiography as reference standard. Correlation analysis of vasospasm severity on perfusion maps and angiographic images was performed. Furthermore, inter-reader agreement was assessed regarding findings on perfusion maps. Diagnostic accuracy for TTD and MTT was significantly higher than for all other perfusion maps (TTD, AUC = 0.832; MTT, AUC = 0.791; p < 0.001). TTD revealed higher sensitivity than MTT (p = 0.007). The severity of vasospasm on TTD maps showed significantly higher correlation levels with angiography than all other perfusion maps (p ≤ 0.048). Inter-reader agreement was (almost) perfect for all perfusion maps (kappa ≥ 0.927). The results of this study indicate that TTD maps have the highest sensitivity for the detection of cerebral vasospasm and highest correlation with angiography regarding the severity of vasospasm. (orig.)

  16. Energy Doubler cryoloop temperature monitor system

    International Nuclear Information System (INIS)

    Pucci, G.; Howard, D.

    1981-10-01

    The Cryoloop Temperature Monitor System is a fully electronic system designed to monitor temperature at key points in the Energy Doubler cryoloop system. It is used for cryoloop diagnostics, temperature studies, and cooldown valve control

  17. Vanishing "tattoo" multisensor for biomedical diagnostics

    Science.gov (United States)

    Moczko, E.; Meglinski, I.; Piletsky, S.

    2008-02-01

    Currently, precise non-invasive diagnostics systems for the real-time multi detection and monitoring of physiological parameters and chemical analytes in the human body are urgently required by clinicians, physiologists and bio-medical researchers. We have developed a novel cost effective smart 'vanishing tattoo' (similar to temporary child's tattoos) consisting of environmental-sensitive dyes. Painlessly impregnated into the skin the smart tattoo is capable of generating optical/fluorescence changes (absorbance, transmission, reflectance, emission and/or luminescence within UV, VIS or NIR regions) in response to physical or chemical changes. These changes allow the identification of colour pattern changes similar to bar-code scanning. Such a system allows an easy, cheap and robust comprehensive detection of various parameters and analytes in a small volume of sample (e.g. variations in pH, temperature, ionic strength, solvent polarity, presence of redox species, surfactants, oxygen). These smart tattoos have possible applications in monitoring the progress of disease and transcutaneous drug delivery. The potential of this highly innovative diagnostic tool is wide and diverse and can impact on routine clinical diagnostics, general therapeutic management, skin care and cosmetic products testing as well as fundamental physiological investigations.

  18. Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    Science.gov (United States)

    Srichai, Monvadi B; Lim, Ruth P; Lath, Narayan; Babb, James; Axel, Leon; Kim, Daniel

    2013-01-01

    We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

  19. On line performance monitoring for predictive maintenance [Paper No.: VIA - 2

    International Nuclear Information System (INIS)

    Gupta, R.K.; Chandra, Rajesh

    1981-01-01

    There will always be progressive deterioration in the performance of dynamic equipment due to normal inevitable wear, malfunctions, failures and other reasons. In most cases it is possible to monitor some parameters of a system which would get progressively affected with the deterioration in the health of the system. By on-line monitoring of such predetermined parameters, compared with preset base data generated for a healthy system earlier, would prove very helpful in avoiding breakdowns and in proper planning of preventive and predictive maintenance. With increasing use of on-line computerised controls the generation of design base data and also the in-built self checking feature of monitoring the equipment health can be achieved by incorporating suitable software. This type of system will be helpful in: (a) predicting the life of component, (b) prewarning the operator about impending malfunctions, (c) establishing a maintenance schedule and spare inventory, and (d) analysing the failures. This type of centralised predictive maintenance is increasingly becoming important where: (a) the number of equipments are large, (b) the operation of equipment is critical from safety criteria, and (c) the minimum safety margin in the performance of the component is to be maintained. Keeping this in mind, the Fuel Handling System of Narora Atomic Power Project and the future power plants having computerised controls will have facility for on-line performance monitoring for predictive maintenance. The paper also describes methodology of the technique in detail, with a few representative cases. (author)

  20. Monitoring and Evaluating Government Performance in Botswana

    Directory of Open Access Journals (Sweden)

    E. K. Botlhale

    2015-03-01

    Full Text Available In an era characterised by fiscal stress in the post-global recession era, clichés such as ‘bang for the buck’ are commonplace. Governments are under increasing pressure to spend limited public resources in efficient and  effective ways. Efficient and  effective governments are a necessary, though not sufficient, condition for economic development. Hence, governments have adopted performance-improving interventions such as New Public Management. Botswana jumped into the bandwagon of public sector reforms in the 1990s through interventions such as Performance-based Management Systems. The focus was almost entirely on performance enhancement to the neglect of performance measurement through a result-based Monitoring and Evaluation (M&E framework. However, in 2009, the government decided to mainstream M&E into the development planning regime. Since the M&E tool is still in draft form, Botswana is very favourably circumstanced to learn from others. Meanwhile essentials to do are: attitudinal change, shared vision on M&E, stakeholder management and demand and use of M&E information by policy-makers such as Members of Parliament.