WorldWideScience

Sample records for performance assessments pas

  1. An Investigation of Interrater Reliability for the Rorschach Performance Assessment System (R-PAS) in a Nonpatient U.S. Sample.

    Science.gov (United States)

    Kivisalu, Trisha M; Lewey, Jennifer H; Shaffer, Thomas W; Canfield, Merle L

    2016-01-01

    The Rorschach Performance Assessment System (R-PAS) aims to provide an evidence-based approach to administration, coding, and interpretation of the Rorschach Inkblot Method (RIM). R-PAS analyzes individualized communications given by respondents to each card to code a wide pool of possible variables. Due to the large number of possible codes that can be assigned to these responses, it is important to consider the concordance rates among different assessors. This study investigated interrater reliability for R-PAS protocols. Data were analyzed from a nonpatient convenience sample of 50 participants who were recruited through networking, local marketing, and advertising efforts from January 2013 through October 2014. Blind recoding was used and discrepancies between the initial and blind coders' ratings were analyzed for each variable with SPSS yielding percent agreement and intraclass correlation values. Data for Location, Space, Contents, Synthesis, Vague, Pairs, Form Quality, Populars, Determinants, and Cognitive and Thematic codes are presented. Rates of agreement for 1,168 responses were higher for more simplistic coding (e.g., Location), whereas agreement was lower for more complex codes (e.g., Cognitive and Thematic codes). Overall, concordance rates achieved good to excellent agreement. Results suggest R-PAS is an effective method with high interrater reliability supporting its empirical basis.

  2. Manual for THOR-AirPAS - air pollution assessment system

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Ketzel, Matthias; Brandt, Jørgen

    The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS.......The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS....

  3. Spanish validation of the Premorbid Adjustment Scale (PAS-S).

    Science.gov (United States)

    Barajas, Ana; Ochoa, Susana; Baños, Iris; Dolz, Montse; Villalta-Gil, Victoria; Vilaplana, Miriam; Autonell, Jaume; Sánchez, Bernardo; Cervilla, Jorge A; Foix, Alexandrina; Obiols, Jordi E; Haro, Josep Maria; Usall, Judith

    2013-02-01

    The Premorbid Adjustment Scale (PAS) has been the most widely used scale to quantify premorbid status in schizophrenia, coming to be regarded as the gold standard of retrospective assessment instruments. To examine the psychometric properties of the Spanish version of the PAS (PAS-S). Retrospective study of 140 individuals experiencing a first episode of psychosis (n=77) and individuals who have schizophrenia (n=63), both adult and adolescent patients. Data were collected through a socio-demographic questionnaire and a battery of instruments which includes the following scales: PAS-S, PANSS, LSP, GAF and DAS-sv. The Cronbach's alpha was performed to assess the internal consistency of PAS-S. Pearson's correlations were performed to assess the convergent and discriminant validity. The Cronbach's alpha of the PAS-S scale was 0.85. The correlation between social PAS-S and total PAS-S was 0.85 (p<0.001); while for academic PAS-S and total PAS-S it was 0.53 (p<0.001). Significant correlations were observed between all the scores of each age period evaluated across the PAS-S scale, with a significance value less than 0.001. There was a relationship between negative symptoms and social PAS-S (0.20, p<0.05) and total PAS-S (0.22, p<0.05), but not with academic PAS-S. However, there was a correlation between academic PAS-S and general subscale of the PANSS (0.19, p<0.05). Social PAS-S was related to disability measures (DAS-sv); and academic PAS-S showed discriminant validity with most of the variables of social functioning. PAS-S did not show association with the total LSP scale (discriminant validity). The Spanish version of the Premorbid Adjustment Scale showed appropriate psychometric properties in patients experiencing a first episode of psychosis and who have a chronic evolution of the illness. Moreover, each domain of the PAS-S (social and academic premorbid functioning) showed a differential relationship to other characteristics such as psychotic symptoms, disability

  4. Organisatiecultuur en performance management : pas op voor het Pavlov-effect

    NARCIS (Netherlands)

    Nieboer, Stephanie

    Dit artikel bespreekt de relatie tussen organisatiecultuur en performance management. De auteurs stellen dat gedrag niet op zichzelf staat, maar wordt gevormd door onderliggende waarden en overtuigingen. Om performance management in de praktijk succesvol te laten zijn, moet het worden opgenomen in

  5. Communicating Performance Assessments Results - 13609

    International Nuclear Information System (INIS)

    Layton, Mark

    2013-01-01

    The F-Area Tank Farms (FTF) and H-Area Tank Farm (HTF) are owned by the U.S. Department of Energy (DOE) and operated by Savannah River Remediation LLC (SRR), Liquid Waste Operations contractor at DOE's Savannah River Site (SRS). The FTF and HTF are active radioactive waste storage and treatment facilities consisting of 51 carbon steel waste tanks and ancillary equipment such as transfer lines, evaporators and pump tanks. Performance Assessments (PAs) for each Tank Farm have been prepared to support the eventual closure of the underground radioactive waste tanks and ancillary equipment. PAs provide the technical bases and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements for final closure of the Tank Farms. The Tank Farms are subject to a number of regulatory requirements. The State regulates Tank Farm operations through an industrial waste water permit and through a Federal Facility Agreement approved by the State, DOE and the Environmental Protection Agency (EPA). Closure documentation will include State-approved Tank Farm Closure Plans and tank-specific closure modules utilizing information from the PAs. For this reason, the State of South Carolina and the EPA must be involved in the performance assessment review process. The residual material remaining after tank cleaning is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005. PAs are performance-based, risk-informed analyses of the fate and transport of FTF and HTF residual wastes following final closure of the Tank Farms. Since the PAs serve as the primary risk assessment tools in evaluating readiness for closure, it is vital that PA conclusions be communicated effectively. In the course of developing the FTF and HTF PAs, several lessons learned have emerged regarding communicating PA results. When communicating PA results it is

  6. Performance assessment

    International Nuclear Information System (INIS)

    Doe, T.

    1985-01-01

    The purpose of performance assessment is to show that the repository is expected to serve its stated function - disposing of radioactive waste safely both during operation and for the postclosure period. Performance assessment is a straightforward concept, but its application may be very complicated. The concept of performance assessment has been clarified by the Nuclear Regulatory Commission (NRC) in their Draft Generic Technical Position on Licensing Assessment Methodology for High-Level Waste Geologic Repositories (NRC, 1984). This document has gone a long way toward defining the criteria that the NRC will use to determine whether or not information from site characterization is adequate to meet the regulations of the Nuclear Regulatory Commission and the Environmental Protection Agency (EPA). A favorable determination is required for issuance of a construction authorization, which is the first major regulatory requirement for developing a working repository. It is, therefore, essential that a research program be developed that not only resolves the outstanding technical issues, but also does it in such a way that the results are clearly applicable to the formal performance assessment and licensing procedures. The definitions of performance assessment are reviewed and the current NRC thinking is summarized

  7. Advance and prospectus of seasonal prediction: assessment of the APCC/CliPAS 14-model ensemble retrospective seasonal prediction (1980-2004)

    Science.gov (United States)

    Wang, Bin; Lee, June-Yi; Kang, In-Sik; Shukla, J.; Park, C.-K.; Kumar, A.; Schemm, J.; Cocke, S.; Kug, J.-S.; Luo, J.-J.; Zhou, T.; Wang, B.; Fu, X.; Yun, W.-T.; Alves, O.; Jin, E. K.; Kinter, J.; Kirtman, B.; Krishnamurti, T.; Lau, N. C.; Lau, W.; Liu, P.; Pegion, P.; Rosati, T.; Schubert, S.; Stern, W.; Suarez, M.; Yamagata, T.

    2009-07-01

    We assessed current status of multi-model ensemble (MME) deterministic and probabilistic seasonal prediction based on 25-year (1980-2004) retrospective forecasts performed by 14 climate model systems (7 one-tier and 7 two-tier systems) that participate in the Climate Prediction and its Application to Society (CliPAS) project sponsored by the Asian-Pacific Economic Cooperation Climate Center (APCC). We also evaluated seven DEMETER models’ MME for the period of 1981-2001 for comparison. Based on the assessment, future direction for improvement of seasonal prediction is discussed. We found that two measures of probabilistic forecast skill, the Brier Skill Score (BSS) and Area under the Relative Operating Characteristic curve (AROC), display similar spatial patterns as those represented by temporal correlation coefficient (TCC) score of deterministic MME forecast. A TCC score of 0.6 corresponds approximately to a BSS of 0.1 and an AROC of 0.7 and beyond these critical threshold values, they are almost linearly correlated. The MME method is demonstrated to be a valuable approach for reducing errors and quantifying forecast uncertainty due to model formulation. The MME prediction skill is substantially better than the averaged skill of all individual models. For instance, the TCC score of CliPAS one-tier MME forecast of Niño 3.4 index at a 6-month lead initiated from 1 May is 0.77, which is significantly higher than the corresponding averaged skill of seven individual coupled models (0.63). The MME made by using 14 coupled models from both DEMETER and CliPAS shows an even higher TCC score of 0.87. Effectiveness of MME depends on the averaged skill of individual models and their mutual independency. For probabilistic forecast the CliPAS MME gains considerable skill from increased forecast reliability as the number of model being used increases; the forecast resolution also increases for 2 m temperature but slightly decreases for precipitation. Equatorial Sea Surface

  8. Advance and prospectus of seasonal prediction: assessment of the APCC/CliPAS 14-model ensemble retrospective seasonal prediction (1980-2004)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Bin; Lee, June-Yi; Fu, X.; Liu, P. [University of Hawaii, Department of Meteorology and International Pacific Research Center, IPRC, School of Ocean and Earth Science and Technology, Honolulu, HI (United States); Kang, In-Sik; Kug, J.S. [Seoul National University, School of Earth and Environmental Sciences, Seoul (Korea); Shukla, J.; Jin, E.K.; Kinter, J.; Kirtman, B. [George Mason University and COLA, Climate Dynamics Program, Calverton, MD (United States); Park, C.K. [APEC Climate Center, Busan (Korea); Kumar, A.; Schemm, J. [Climate Prediction Center/NCEP, Camp Springs, MD (United States); Cocke, S.; Krishnamurti, T. [Florida State University, Tallahassee, FL (United States); Luo, J.J. [Frontier Research Center for Global Chnage, Yokohama (Japan); Zhou, T.; Wang, B. [Chinese Academy of Sciences, LASG/Institute of Atmospheric Physics, Beijing (China); Yun, W.T. [Korean Meteorological Administration, Seoul (Korea); Alves, O. [Bureau of Meteorology Research Center, Melburne (Australia); Lau, N.C.; Rosati, T.; Stern, W. [Princeton University, Geophysical Fluid Dynamics Laboratory/NOAA, Princeton, NJ (United States); Lau, W.; Pegion, P.; Schubert, S.; Suarez, M. [Godard Space Flight Center/NASA, Greenbelt, MD (United States)

    2009-07-15

    We assessed current status of multi-model ensemble (MME) deterministic and probabilistic seasonal prediction based on 25-year (1980-2004) retrospective forecasts performed by 14 climate model systems (7 one-tier and 7 two-tier systems) that participate in the Climate Prediction and its Application to Society (CliPAS) project sponsored by the Asian-Pacific Economic Cooperation Climate Center (APCC). We also evaluated seven DEMETER models' MME for the period of 1981-2001 for comparison. Based on the assessment, future direction for improvement of seasonal prediction is discussed. We found that two measures of probabilistic forecast skill, the Brier Skill Score (BSS) and Area under the Relative Operating Characteristic curve (AROC), display similar spatial patterns as those represented by temporal correlation coefficient (TCC) score of deterministic MME forecast. A TCC score of 0.6 corresponds approximately to a BSS of 0.1 and an AROC of 0.7 and beyond these critical threshold values, they are almost linearly correlated. The MME method is demonstrated to be a valuable approach for reducing errors and quantifying forecast uncertainty due to model formulation. The MME prediction skill is substantially better than the averaged skill of all individual models. For instance, the TCC score of CliPAS one-tier MME forecast of Nino 3.4 index at a 6-month lead initiated from 1 May is 0.77, which is significantly higher than the corresponding averaged skill of seven individual coupled models (0.63). The MME made by using 14 coupled models from both DEMETER and CliPAS shows an even higher TCC score of 0.87. Effectiveness of MME depends on the averaged skill of individual models and their mutual independency. For probabilistic forecast the CliPAS MME gains considerable skill from increased forecast reliability as the number of model being used increases; the forecast resolution also increases for 2 m temperature but slightly decreases for precipitation. Equatorial Sea Surface

  9. Guidance for performing preliminary assessments under CERCLA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-09-01

    EPA headquarters and a national site assessment workgroup produced this guidance for Regional, State, and contractor staff who manage or perform preliminary assessments (PAs). EPA has focused this guidance on the types of sites and site conditions most commonly encountered. The PA approach described in this guidance is generally applicable to a wide variety of sites. However, because of the variability among sites, the amount of information available, and the level of investigative effort required, it is not possible to provide guidance that is equally applicable to all sites. PA investigators should recognize this and be aware that variation from this guidance may be necessary for some sites, particularly for PAs performed at Federal facilities, PAs conducted under EPA`s Environmental Priorities Initiative (EPI), and PAs at sites that have previously been extensively investigated by EPA or others. The purpose of this guidance is to provide instructions for conducting a PA and reporting results. This guidance discusses the information required to evaluate a site and how to obtain it, how to score a site, and reporting requirements. This document also provides guidelines and instruction on PA evaluation, scoring, and the use of standard PA scoresheets. The overall goal of this guidance is to assist PA investigators in conducting high-quality assessments that result in correct site screening or further action recommendations on a nationally consistent basis.

  10. Communicating Performance Assessments Results - 13609

    Energy Technology Data Exchange (ETDEWEB)

    Layton, Mark [Savannah River Remediation LLC, Building 705-1C, Aiken, SC 29808 (United States)

    2013-07-01

    The F-Area Tank Farms (FTF) and H-Area Tank Farm (HTF) are owned by the U.S. Department of Energy (DOE) and operated by Savannah River Remediation LLC (SRR), Liquid Waste Operations contractor at DOE's Savannah River Site (SRS). The FTF and HTF are active radioactive waste storage and treatment facilities consisting of 51 carbon steel waste tanks and ancillary equipment such as transfer lines, evaporators and pump tanks. Performance Assessments (PAs) for each Tank Farm have been prepared to support the eventual closure of the underground radioactive waste tanks and ancillary equipment. PAs provide the technical bases and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements for final closure of the Tank Farms. The Tank Farms are subject to a number of regulatory requirements. The State regulates Tank Farm operations through an industrial waste water permit and through a Federal Facility Agreement approved by the State, DOE and the Environmental Protection Agency (EPA). Closure documentation will include State-approved Tank Farm Closure Plans and tank-specific closure modules utilizing information from the PAs. For this reason, the State of South Carolina and the EPA must be involved in the performance assessment review process. The residual material remaining after tank cleaning is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005. PAs are performance-based, risk-informed analyses of the fate and transport of FTF and HTF residual wastes following final closure of the Tank Farms. Since the PAs serve as the primary risk assessment tools in evaluating readiness for closure, it is vital that PA conclusions be communicated effectively. In the course of developing the FTF and HTF PAs, several lessons learned have emerged regarding communicating PA results. When communicating PA results it is

  11. Internal and atmospheric contamination measurament by means of whole body counter performed up to 31.21.1986 by Bologna ENEA-PAS following the Chernobyl accident

    International Nuclear Information System (INIS)

    Melandri, C.; Castellani, C.M.; Calamosca, M.; Torroni, G.; Formignani, M.; De Zaiacomo, T.

    1987-01-01

    Internal contamination and atmospheric sampling data obtained at ENEA PAS-FIBI-AEROSOL Laboratory in Bologna (Italy), following the accident at the nuclear reactor in Chernobyl, are presented. Internal contamination data are related to persons coming from European countries (mainly the USSR) and Italy, measured in Bologna in the period May-Dicember 1986, while the atmospheric contamination samplings were performed in Bologna during the first decade of May. Descriptions of the measurement methods, data analysis and the evaluation of the committed dose equivalent due to both inhalation and ingestion of radioactive contaminants are given. The last chapter reports an estimation of the possible trend of internal contamination due to Cs-134 and Cs-137 up to 1991

  12. PAs: Fifty years young.

    Science.gov (United States)

    Mandel, Ellen D; North, Shannon

    2017-10-01

    The PA profession is 50 years young. Practicing PAs and current students hail from several generational categories ranging from Builders to Generation Z. This article reviews how different generations may have experienced PA program expansion, professional identity, state licensing, and prescription delegation. The authors sampled a cohort of PA program applicants about their views on what evokes optimism and concern for the PA profession. These themes mirror the recently paved professional road, while posing the all-important question: What construction lies on the horizon?

  13. Form Quality in Rorschach Comprehensive System and R-PAS: Sample of Psychiatric Cases

    Directory of Open Access Journals (Sweden)

    Latife Yazigi

    2016-04-01

    Full Text Available Abstract The creation of the Rorschach Performance Assessment System (R-PAS requires research that allows its use in the Brazilian population. The Formal Quality (FQ category is essential both for clinic and research. The aim of this study was to compare form quality variables in Rorschach protocols from psychiatric patients and ratings coded in the Comprehensive System (CS and R-PAS. The sample comprised 206 Rorschach protocols from adult patients in psychiatric treatment, who were also assessed by SCID-I and SCID-II. Most protocols were administered in the CS and recoded according to the R-PAS. The kappa coefficient was calculated, and we compared the means of these variables in both systems. The kappa results varied from almost perfect to substantial consistency for all variables, however, the descriptive statistics confirmed that the R-PAS elicits more FQ Ordinary coding while the CS elicits more FQ minus coding.

  14. Performance assessment task team progress report

    International Nuclear Information System (INIS)

    Wood, D.E.; Curl, R.U.; Armstrong, D.R.; Cook, J.R.; Dolenc, M.R.; Kocher, D.C.; Owens, K.W.; Regnier, E.P.; Roles, G.W.; Seitz, R.R.

    1994-05-01

    The U.S. Department of Energy (DOE) Headquarters EM-35, established a Performance Assessment Task Team (referred to as the Team) to integrate the activities of the sites that are preparing performance assessments (PAs) for disposal of new low-level waste, as required by Chapter III of DOE Order 5820.2A, open-quotes Low-Level Waste Managementclose quotes. The intent of the Team is to achieve a degree of consistency among these PAs as the analyses proceed at the disposal sites. The Team's purpose is to recommend policy and guidance to the DOE on issues that impact the PAs, including release scenarios and parameters, so that the approaches are as consistent as possible across the DOE complex. The Team has identified issues requiring attention and developed discussion papers for those issues. Some issues have been completed, and the recommendations are provided in this document. Other issues are still being discussed, and the status summaries are provided in this document. A major initiative was to establish a subteam to develop a set of test scenarios and parameters for benchmarking codes in use at the various sites. The activities of the Team are reported here through December 1993

  15. Uncertainties in Organ Burdens Estimated from PAS

    International Nuclear Information System (INIS)

    La Bone, T.R.

    2004-01-01

    To calculate committed effective dose equivalent, one needs to know the quantity of the radionuclide in all significantly irradiated organs (the organ burden) as a function of time following the intake. There are two major sources of uncertainty in an organ burden estimated from personal air sampling (PAS) data: (1) The uncertainty in going from the exposure measured with the PAS to the quantity of aerosol inhaled by the individual, and (2) The uncertainty in going from the intake to the organ burdens at any given time, taking into consideration the biological variability of the biokinetic models from person to person (interperson variability) and in one person over time (intra-person variability). We have been using biokinetic modeling methods developed by researchers at the University of Florida to explore the impact of inter-person variability on the uncertainty of organ burdens estimated from PAS data. These initial studies suggest that the uncertainties are so large that PAS might be considered to be a qualitative (rather than quantitative) technique. These results indicate that more studies should be performed to properly classify the reliability and usefulness of using PAS monitoring data to estimate organ burdens, organ dose, and ultimately CEDE

  16. Psychometric Evaluation of a Dutch Version of the Mini PAS-ADD for Assessing Psychiatric Disorders in Adults with Different Levels of Intellectual Disability

    Science.gov (United States)

    Janssen, R.; Maes, B.

    2013-01-01

    Background: People with intellectual disabilities (ID) have an increased vulnerability to develop psychiatric problems. Moreover, the early recognition and the accurate diagnosis of psychiatric disorders in the population of persons with ID are challenging. Method: A Dutch version of the Mini PAS-ADD, which is a screening instrument for…

  17. Performance Assessment Strategies: A computational framework for conceptual design of large roofs

    Directory of Open Access Journals (Sweden)

    Michela Turrin

    2014-01-01

    Full Text Available Using engineering performance evaluations to explore design alternatives during the conceptual phase of architectural design helps to understand the relationships between form and performance; and is crucial for developing well-performing final designs. Computer aided conceptual design has the potential to aid the design team in discovering and highlighting these relationships; especially by means of procedural and parametric geometry to support the generation of geometric design, and building performance simulation tools to support performance assessments. However, current tools and methods for computer aided conceptual design in architecture do not explicitly reveal nor allow for backtracking the relationships between performance and geometry of the design. They currently support post-engineering, rather than the early design decisions and the design exploration process. Focusing on large roofs, this research aims at developing a computational design approach to support designers in performance driven explorations. The approach is meant to facilitate the multidisciplinary integration and the learning process of the designer; and not to constrain the process in precompiled procedures or in hard engineering formulations, nor to automatize it by delegating the design creativity to computational procedures. PAS (Performance Assessment Strategies as a method is the main output of the research. It consists of a framework including guidelines and an extensible library of procedures for parametric modelling. It is structured on three parts. Pre-PAS provides guidelines for a design strategy-definition, toward the parameterization process. Model-PAS provides guidelines, procedures and scripts for building the parametric models. Explore-PAS supports the solutions-assessment based on numeric evaluations and performance simulations, until the identification of a suitable design solution. PAS has been developed based on action research. Several case studies

  18. Psychometric evaluation of a Dutch version of the Mini PAS-ADD for assessing psychiatric disorders in adults with different levels of intellectual disability

    OpenAIRE

    Janssen, Rianne; Maes, Bea

    2013-01-01

    Background People with intellectual disabilities (ID) have an increased vulnerability to develop psychiatric problems. Moreover, the early recognition and the accurate diagnosis of psychiatric disorders in the population of persons with ID are challenging. Method A Dutch version of the Mini PAS-ADD, which is a screening instrument for identification of mental health problems in people with ID, was evaluated in terms of internal consistency, interinformant reliability, item grouping and ...

  19. Psychometric evaluation of a Dutch version of the Mini PAS-ADD for assessing psychiatric disorders in adults with different levels of intellectual disability.

    Science.gov (United States)

    Janssen, R; Maes, B

    2013-08-01

    People with intellectual disabilities (ID) have an increased vulnerability to develop psychiatric problems. Moreover, the early recognition and the accurate diagnosis of psychiatric disorders in the population of persons with ID are challenging. A Dutch version of the Mini PAS-ADD, which is a screening instrument for identification of mental health problems in people with ID, was evaluated in terms of internal consistency, interinformant reliability, item grouping and criterion validity based on a large-scale random sample (n = 377) and a clinical sample (n = 99) of adults with ID. The Dutch version of the Mini PAS-ADD showed moderate internal consistency, and moderate concordance among informants. Both aspects of the reliability were comparable for different levels of ID. A factor analysis largely confirmed the scale structure. Concurrent validity with the Reiss Screen for Maladaptive Behavior was high for the Depression, Psychosis and Autism scale. The outcome of the criterion-validity analysis indicated high specificity. The sensitivity for specific psychiatric disorders by the corresponding scales was moderate, but the general sensitivity for the presence of psychopathology on the basis of any of the scales was satisfying. The present research reconfirmed the use of the Mini PAS-ADD as a primary screening device for the identification of mental health problems among people with ID. © 2012 The Authors. Journal of Intellectual Disability Research © 2012 John Wiley & Sons Ltd, MENCAP & IASSID.

  20. Process of performance assessment

    International Nuclear Information System (INIS)

    King, C.M.; Halford, D.K.

    1987-01-01

    Performance assessment is the process used to evaluate the environmental consequences of disposal of radioactive waste in the biosphere. An introductory review of the subject is presented. Emphasis is placed on the process of performance assessment from the standpoint of defining the process. Performance assessment, from evolving experience at DOE sites, has short-term and long-term subprograms, the components of which are discussed. The role of mathematical modeling in performance assessment is addressed including the pros and cons of current approaches. Finally, the system/site/technology issues as the focal point of this symposium are reviewed

  1. NRC performance assessment program

    International Nuclear Information System (INIS)

    Coplan, S.M.

    1986-01-01

    The U.S. Nuclear Regulatory Commission's (NRC) performance assessment program includes the development of guidance to the U.S. Department of Energy (DOE) on preparation of a license application and on conducting the studies to support a license application. The nature of the licensing requirements of 10 CFR Part 60 create a need for performance assessments by the DOE. The NRC and DOE staffs each have specific roles in assuring the adequacy of those assessments. Performance allocation is an approach for determining what testing and analysis will be needed during site characterization to assure that an adequate data base is available to support the necessary performance assessments. From the standpoint of establishing is implementable methodology, the most challenging performance assessment needed for licensing is the one that will be used to determine compliance with the U.S. Environmental Protection Agency's (EPA) containment requirement

  2. Ford Partnership for Advanced Studies (Ford PAS)

    Science.gov (United States)

    Carrier, Cheryl

    2006-01-01

    This article features the Ford Partnership for Advanced Studies (Ford PAS) program that helps students gain knowledge about real-life business issues. Ford PAS is an educational program that combines college-prep academics with the critical 21st century skills students will need to succeed in college and in the workplace. The Ford PAS program uses…

  3. Three instruments for positron annihilation spectroscopy (PAS)

    International Nuclear Information System (INIS)

    Ivanov, E.A.; Plostinaru, D.; Catana, D.; Racolta, P.M.; Vata, I.

    2003-01-01

    The instruments presented here and dedicated to positron annihilation spectroscopy, PAS, are: 1. High Resolution Life Time Spectrometer (LTS) with time resolution τ = 260 ps, based on large BaF 2 scintillators; 2. Doppler Broadening Spectrometer (DBS) having a 1.6 keV resolution at 514 keV; 3. Positronium Life Time - Perturbed Angular Distribution Spectrometer ( PLT-PAD); positronium life time, in samples under high vacuum in magnetic field, is measured for time intervals up to 500 ns. Results of measurements are shown to illustrate performances of the instruments. (authors)

  4. A history of US Army PAs.

    Science.gov (United States)

    Chalupa, Robyn L; Marble, W Sanders

    2017-11-01

    The US military has a long tradition of using physician assistants (PAs). The Army began using PAs in 1971 in an effort to supplement the physicians and surgeons in the medical corps. As their numbers grew, PAs gradually replaced general medical officers assigned to battalions. Later, specialty positions developed in aviation medicine, orthopedics, and emergency medicine. The need for a PA serving as an adviser in the major commands slowly developed at all levels of leadership. In 2015, the Army removed limitations on female PAs assigned to combat units. PAs lead in tactical and clinical settings, filling command roles, senior clinical positions, and administrative leadership roles.

  5. Assessing Scientific Performance.

    Science.gov (United States)

    Weiner, John M.; And Others

    1984-01-01

    A method for assessing scientific performance based on relationships displayed numerically in published documents is proposed and illustrated using published documents in pediatric oncology for the period 1979-1982. Contributions of a major clinical investigations group, the Childrens Cancer Study Group, are analyzed. Twenty-nine references are…

  6. Performance assessment calculational exercises

    International Nuclear Information System (INIS)

    Barnard, R.W.; Dockery, H.A.

    1990-01-01

    The Performance Assessment Calculational Exercises (PACE) are an ongoing effort coordinated by Yucca Mountain Project Office. The objectives of fiscal year 1990 work, termed PACE-90, as outlined in the Department of Energy Performance Assessment (PA) Implementation Plan were to develop PA capabilities among Yucca Mountain Project (YMP) participants by calculating performance of a Yucca Mountain (YM) repository under ''expected'' and also ''disturbed'' conditions, to identify critical elements and processes necessary to assess the performance of YM, and to perform sensitivity studies on key parameters. It was expected that the PACE problems would aid in development of conceptual models and eventual evaluation of site data. The PACE-90 participants calculated transport of a selected set of radionuclides through a portion of Yucca Mountain for a period of 100,000 years. Results include analyses of fluid-flow profiles, development of a source term for radionuclide release, and simulations of contaminant transport in the fluid-flow field. Later work included development of a problem definition for perturbations to the originally modeled conditions and for some parametric sensitivity studies. 3 refs

  7. Context for performance assessment

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1997-01-01

    In developing its recommendations on performance assessment for disposal of low-level radioactive waste, Scientific committee 87-3 of the National Council on Radiation Protection and Measurements (NCRP) has considered a number of topics that provide a context for the development of suitable approaches to performance assessment. This paper summarizes the Committee' discussions on these topics, including (1) the definition of low-level waste and its sources and properties, as they affect the variety of wastes that must be considered, (2) fundamental objectives and principles of radioactive waste disposal and their application to low-level waste, (3) current performance objectives for low-level waste disposal in the US, with particular emphasis on such unresolved issues of importance to performance assessment as the time frame for compliance, requirements for protection of groundwater and surface water, inclusion of doses from radon, demonstrating compliance with fixed performance objectives using highly uncertain model projections, and application of the principle that releases to the environment should be maintained as low as reasonably achievable (ALARA), (4) the role of active and passive institutional controls over disposal sites, (5) the role of the inadvertent human intruder in low-level waste disposal, (6) model validation and confidence in model outcomes, and (7) the concept of reasonable assurance of compliance

  8. Texas' performance assessment work

    International Nuclear Information System (INIS)

    Charbeneau, R.J.; Hertel, N.E.; Pollard, C.G.

    1990-01-01

    The Texas Low-Level Radioactive Waste Disposal Authority is completing two years of detailed on-site suitability studies of a potential low-level radioactive waste disposal site in Hudspeth County, Texas. The data from these studies have been used to estimate site specific parameters needed to do a performance assessment of the site. The radiological impacts of the site have been analyzed as required for a license application. The approach adopted for the performance assessment was to use simplified and yet conservative assumptions with regard to releases, radionuclide transport, and dose calculations. The methodologies employed in the performance assessment are reviewed in the paper. Rather than rely on a single computer code, a modular approach to the performance assessment was selected. The HELP code was used to calculate the infiltration rate through the trench covers and the amount of leachate released from this arid site. Individual pathway analyses used spreadsheet calculations. These calculations were compared with those from other computer models including CRRIS, INGDOS, PATHRAE, and MICROSHIELD copyright, and found to yield conservative estimates of the effective whole body dose. The greatest difficulty in performing the radiological assessment of the site was the selection of reasonable source terms for release into the environment. A surface water pathway is unreasonable for the site. Though also unlikely, the groundwater pathway with exposure through a site boundary well was found to yield the largest calculated dose. The more likely pathway including transport of leachate from the facility through the unsaturated zone and returning to the ground surface yields small doses. All calculated doses associated with normal releases of radioactivity are below the regulatory limits

  9. 2011 PERFORMANCE ASSESSMENT COMMUNITY OF PRACTICE TECHNICAL EXCHANGE - SUMMARY

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, R.

    2011-12-30

    The Performance Assessment Community of Practice (PA CoP) was developed in 2008 to improve consistency and quality in the preparation of performance assessments (PAs) and risk assessments across the Department of Energy (DOE) Complex. The term, PA, is used to represent all of these modeling applications in this report. The PA CoP goals are to foster the exchange of information among PA practitioners and to share lessons learned from PAs conducted for DOE, commercial disposal facilities, and international entities. Technical exchanges and workshops are a cornerstone of PA CoP activities. Previous technical exchanges have addressed Engineered Barriers (2009 - http://www.cresp.org/education/workshops/pacop/), the Advanced Simulation Capability for Environmental Management and the Cementitious Barriers Partnership (2010 - http://srnl.doe.gov/copexchange/links.htm). Each technical exchange also includes summary presentations regarding activities at DOE, the Nuclear Regulatory Commission (NRC) and other organizations (e.g., International Atomic Energy Agency (IAEA)) as well as a number of presentations from selected sites to provide insight and perspective from on-going modeling activities. Through the deployment of PA Assistance Teams, the PA CoP has also been engaged in the development of new PAs across the DOE Complex. As a way of improving consistency in the preparation of new PAs, the teams provide technical advice and share experiences, noteworthy practices, and lessons learned from previous Low-Level Waste Disposal Facility Federal Review Group (LFRG) reviews. Teams have provided support for PAs at Hanford, Idaho, Paducah and Portsmouth. The third annual PA CoP Technical Exchange was held on May 25-26, 2011 in Atlanta, GA. The PA CoP Steering Committee Meeting held its first meeting on May 24 prior to the Technical Exchange. Decision making using models and software quality assurance were the topical emphasis for the exchange. A new feature at the 2011 technical

  10. Energy performance assessment methodology

    Energy Technology Data Exchange (ETDEWEB)

    Platzer, W.J. [Fraunhofer Inst. for Solar Energy Systems, Freiburg (Germany)

    2006-01-15

    The energy performance of buildings are intimately connected to the energy performance of building envelopes. The better we understand the relation between the quality of the envelope and the energy consumption of the building, the better we can improve both. We have to consider not only heating but all service energies related to the human comfort in the building, such as cooling, ventilation, lighting as well. The complexity coming from this embracing approach is not to be underestimated. It is less and less possible to realted simple characteristic performance indicators of building envelopes (such as the U-value) to the overall energy performance. On the one hand much more paramters (e.g. light transmittance) come into the picture we have to assess the product quality in a multidimensional world. Secondly buildings more and more have to work on a narrow optimum: For an old, badly insulated building all solar gains are useful for a high-performance building with very good insulation and heat recovery systems in the ventilation overheating becomes more likely. Thus we have to control the solar gains, and sometimes we need high gains, sometimes low ones. And thirdly we see that the technology within the building and the user patterns and interactions as well influence the performance of a building envelope. The aim of this project within IEA Task27 was to improve our knowledge on the complex situation and also to give a principal approach how to assess the performance of the building envelope. The participants have contributed to this aim not pretending that we have reached the end. (au)

  11. Waste package performance assessment

    International Nuclear Information System (INIS)

    Lester, D.H.

    1981-01-01

    This paper describes work undertaken to assess the life-expectancy and post-failure nuclide release behavior of high-level and waste packages in a geologic repository. The work involved integrating models of individual phenomena (such as heat transfer, corrosion, package deformation, and nuclide transport) and using existing data to make estimates of post-emplacement behavior of waste packages. A package performance assessment code was developed to predict time to package failure in a flooded repository and subsequent transport of nuclides out of the leaking package. The model has been used to evaluate preliminary package designs. The results indicate, that within the limitation of model assumptions and data base, packages lasting a few hundreds of years could be developed. Very long lived packages may be possible but more comprehensive data are needed to confirm this

  12. TURVA-2012: Performance assessment

    International Nuclear Information System (INIS)

    Hellae, Pirjo; Snellman, Margit; Marcos, Nuria; Pastina, Barbara; Smith, Paul; Koskinen, Kari

    2014-01-01

    TURVA-2012 is Posiva's safety case in support of the Preliminary Safety Analysis Report (PSAR) and application for a construction licence for a repository for disposal of spent nuclear fuel at the Olkiluoto site in south-western Finland. Posiva's safety concept is based on long-term isolation and containment, which is achieved through a robust engineered barrier system (EBS) design and favourable geological conditions at the repository site. The reference design considered in the TURVA-2012 safety case is the KBS-3V design, with the EBS consisting of a copper-iron canister, a buffer of swelling clay material, a backfill in the deposition tunnels of low-permeability material and closure of the central tunnels and other underground openings. The host rock acts as a natural barrier. Each barrier contributes to safety through one or more safety function. The conditions needed for the barriers to fulfil their respective safety functions are expressed in terms of performance targets for the EBS and the target properties for the host rock. The performance assessment (Posiva, 2013), which is a key component of TURVA-2012, analyses the ability of the repository system to provide containment and isolation of the spent nuclear fuel during the long-term evolution of the system and the site. The conditions needed for the barriers to fulfil their respective safety functions are expressed in terms of performance targets for the engineered barriers and target properties for the host rock, for example properties related to the corrosion resistance and mechanical strength of the canister as well as groundwater flow and composition. The analyses take into account the uncertainties in the initial state, the subsequent thermal, hydraulic, mechanical and chemical evolution of the repository system and uncertainties in the evolution. The conclusions of the performance assessment are based mostly on the output of key modelling activities. Whenever modelling is not possible the conclusions

  13. Evolution of US DOE Performance Assessments Over 20 Years - 13597

    Energy Technology Data Exchange (ETDEWEB)

    Suttora, Linda C. [U.S. Department of Energy, Office of Site Restoration, 19901 Germantown Rd, Germantown, MD 20874-1290 (United States); Seitz, Roger R. [Savannah River National Laboratory, Savannah River Site, Bldg 773-43A, Aiken, SC 29808 (United States)

    2013-07-01

    Performance assessments (PAs) have been used for many years for the analysis of post-closure hazards associated with a radioactive waste disposal facility and to provide a reasonable expectation of the ability of the site and facility design to meet objectives for the protection of members of the public and the environment. The use of PA to support decision-making for LLW disposal facilities has been mandated in United States Department of Energy (US DOE) directives governing radioactive waste management since 1988 (currently DOE Order 435.1, Radioactive Waste Management). Prior to that time, PAs were also used in a less formal role. Over the past 20+ years, the US DOE approach to conduct, review and apply PAs has evolved into an efficient, rigorous and mature process that includes specific requirements for continuous improvement and independent reviews. The PA process has evolved through refinement of a graded and iterative approach designed to help focus efforts on those aspects of the problem expected to have the greatest influence on the decision being made. Many of the evolutionary changes to the PA process are linked to the refinement of the PA maintenance concept that has proven to be an important element of US DOE PA requirements in the context of supporting decision-making for safe disposal of LLW. The PA maintenance concept is central to the evolution of the graded and iterative philosophy and has helped to drive the evolution of PAs from a deterministic compliance calculation into a systematic approach that helps to focus on critical aspects of the disposal system in a manner designed to provide a more informed basis for decision-making throughout the life of a disposal facility (e.g., monitoring, research and testing, waste acceptance criteria, design improvements, data collection, model refinements). A significant evolution in PA modeling has been associated with improved use of uncertainty and sensitivity analysis techniques to support efficient

  14. Evolution Of USDOE Performance Assessments Over 20 Years

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, Roger R. [Savannah River Site (SRS), Aiken, SC (United States); Suttora, Linda C. [U.S. Department of Energy, Office of Site Restoration, Germantown, MD (United States)

    2013-02-26

    Performance assessments (PAs) have been used for many years for the analysis of post-closure hazards associated with a radioactive waste disposal facility and to provide a reasonable expectation of the ability of the site and facility design to meet objectives for the protection of members of the public and the environment. The use of PA to support decision-making for LLW disposal facilities has been mandated in United States Department of Energy (USDOE) directives governing radioactive waste management since 1988 (currently DOE Order 435.1, Radioactive Waste Management). Prior to that time, PAs were also used in a less formal role. Over the past 20+ years, the USDOE approach to conduct, review and apply PAs has evolved into an efficient, rigorous and mature process that includes specific requirements for continuous improvement and independent reviews. The PA process has evolved through refinement of a graded and iterative approach designed to help focus efforts on those aspects of the problem expected to have the greatest influence on the decision being made. Many of the evolutionary changes to the PA process are linked to the refinement of the PA maintenance concept that has proven to be an important element of USDOE PA requirements in the context of supporting decision-making for safe disposal of LLW. The PA maintenance concept represents the evolution of the graded and iterative philosophy and has helped to drive the evolution of PAs from a deterministic compliance calculation into a systematic approach that helps to focus on critical aspects of the disposal system in a manner designed to provide a more informed basis for decision-making throughout the life of a disposal facility (e.g., monitoring, research and testing, waste acceptance criteria, design improvements, data collection, model refinements). A significant evolution in PA modeling has been associated with improved use of uncertainty and sensitivity analysis techniques to support efficient

  15. Evolution Of USDOE Performance Assessments Over 20 Years

    International Nuclear Information System (INIS)

    Seitz, Roger R.; Suttora, Linda C.

    2013-01-01

    Performance assessments (PAs) have been used for many years for the analysis of post-closure hazards associated with a radioactive waste disposal facility and to provide a reasonable expectation of the ability of the site and facility design to meet objectives for the protection of members of the public and the environment. The use of PA to support decision-making for LLW disposal facilities has been mandated in United States Department of Energy (USDOE) directives governing radioactive waste management since 1988 (currently DOE Order 435.1, Radioactive Waste Management). Prior to that time, PAs were also used in a less formal role. Over the past 20+ years, the USDOE approach to conduct, review and apply PAs has evolved into an efficient, rigorous and mature process that includes specific requirements for continuous improvement and independent reviews. The PA process has evolved through refinement of a graded and iterative approach designed to help focus efforts on those aspects of the problem expected to have the greatest influence on the decision being made. Many of the evolutionary changes to the PA process are linked to the refinement of the PA maintenance concept that has proven to be an important element of USDOE PA requirements in the context of supporting decision-making for safe disposal of LLW. The PA maintenance concept represents the evolution of the graded and iterative philosophy and has helped to drive the evolution of PAs from a deterministic compliance calculation into a systematic approach that helps to focus on critical aspects of the disposal system in a manner designed to provide a more informed basis for decision-making throughout the life of a disposal facility (e.g., monitoring, research and testing, waste acceptance criteria, design improvements, data collection, model refinements). A significant evolution in PA modeling has been associated with improved use of uncertainty and sensitivity analysis techniques to support efficient

  16. Evolution of US DOE Performance Assessments Over 20 Years - 13597

    International Nuclear Information System (INIS)

    Suttora, Linda C.; Seitz, Roger R.

    2013-01-01

    Performance assessments (PAs) have been used for many years for the analysis of post-closure hazards associated with a radioactive waste disposal facility and to provide a reasonable expectation of the ability of the site and facility design to meet objectives for the protection of members of the public and the environment. The use of PA to support decision-making for LLW disposal facilities has been mandated in United States Department of Energy (US DOE) directives governing radioactive waste management since 1988 (currently DOE Order 435.1, Radioactive Waste Management). Prior to that time, PAs were also used in a less formal role. Over the past 20+ years, the US DOE approach to conduct, review and apply PAs has evolved into an efficient, rigorous and mature process that includes specific requirements for continuous improvement and independent reviews. The PA process has evolved through refinement of a graded and iterative approach designed to help focus efforts on those aspects of the problem expected to have the greatest influence on the decision being made. Many of the evolutionary changes to the PA process are linked to the refinement of the PA maintenance concept that has proven to be an important element of US DOE PA requirements in the context of supporting decision-making for safe disposal of LLW. The PA maintenance concept is central to the evolution of the graded and iterative philosophy and has helped to drive the evolution of PAs from a deterministic compliance calculation into a systematic approach that helps to focus on critical aspects of the disposal system in a manner designed to provide a more informed basis for decision-making throughout the life of a disposal facility (e.g., monitoring, research and testing, waste acceptance criteria, design improvements, data collection, model refinements). A significant evolution in PA modeling has been associated with improved use of uncertainty and sensitivity analysis techniques to support efficient

  17. Criterion validity of the Physical Activity Scale (PAS2) in Danish adults

    DEFF Research Database (Denmark)

    Lunde Pedersen, Eva Sophie; Mortensen, L H; Brage, S

    2017-01-01

    BACKGROUND: The Physical Activity Scale (PAS2) was developed to measure physical activity (PA) during work, transportation and leisure time, in the Danish adult population. The objective of this study was to assess the criterion validity of PAS2 against a combined accelerometer and heart rate mon...

  18. Survey and review of near-field performance assessment

    International Nuclear Information System (INIS)

    Apted, M.J.

    1993-01-01

    The aim of this chapter is to describe the performance assessment (PA) context in which near-field models have been developed and applied. An overview is given of a number of PA studies. Although the focus is on near-field models, the overview covers the full context in which the PAs have been performed, including the purpose of the studies and regulatory context. Special emphasis has been given to the scenarios analyzed in the assessments; the scenarios set the framework for model development and application. Another aspect to consider in a study of near-field modeling from the perspective of total PA is the linking between near-field and far-field assessment. (R.P.) 6 tabs

  19. Georgia's Teacher Performance Assessment

    Science.gov (United States)

    Fenton, Anne Marie; Wetherington, Pamela

    2016-01-01

    Like most states, Georgia until recently depended on an assessment of content knowledge to award teaching licenses, along with a licensure recommendation from candidates' educator preparation programs. While the content assessment reflected candidates' grasp of subject matter, licensure decisions did not hinge on direct, statewide assessment of…

  20. OLEM Performance Assessment Information

    Data.gov (United States)

    U.S. Environmental Protection Agency — This asset includes a variety of data sets that measure the performance of Office of Land and Emergency Management (OLEM) programs in support of the Office of the...

  1. Simply Performance Assessment

    Science.gov (United States)

    McLaughlin, Cheryl A.; McLaughlin, Felecia C.; Pringle, Rose M.

    2013-01-01

    This article presents the experiences of Miss Felecia McLaughlin, a fourth-grade teacher from the island of Jamaica who used the model proposed by Bass et al. (2009) to assess conceptual understanding of four of the six types of simple machines while encouraging collaboration through the creation of learning teams. Students had an opportunity to…

  2. Assessment of wheel propeller contact pressure upon soil with use of tire universal performance

    Directory of Open Access Journals (Sweden)

    Z. A. Godzhaev

    2016-01-01

    Full Text Available A maximum contact pressure is a key parameter characterizing a level of ecological impact of tractor propellers on the soil. The maximum pressure upon the soil varies with internal pressure in tires and vertical load of a wheel. An universal tire performance can be used at an assessment of change of contact pressure of a wheel propeller upon the soil. The authors offered a technique of definition and regulation of the maximum contact pressure of the wheel propeller upon the basic basis. This technique allows to set parameters for monitoring systems and regulation of the maximum pressure upon the soil by measurement of a tire deflection and change of pressure in tires. At statistical tests for determination of the maximum contact pressure it is necessary to consider the universal performance of the tire nomographically. This nomogram allows to consider visually influence of loading and internal pressure in the tire on a size of the maximum contact pressure. An internal pressure decrease in the tire makes it possible to reduce the maximum pressure upon the soil at constant loading. The authors investigated universal performances of the tires in the range of change of internal air pressure from 160 to 90 kPas. Change of internal pressure from 150 to 100 kPas reduce for the tire 15,5R38 the maximum contact pressure upon 13 kPas (9,6 percent: from 135 to 122 kPas. That corresponds to the admissible level of pressure upon the soil at its humidity in a layer of 0-30 cm: 0,5-0,6 minimum moisture-holding capacity during the spring period and 0,6-0,7 minimum moisture-holding capacity during the autumn period. In case of use of the tire 16,9R38 the maximum pressure upon the soil decreases from 84 to 75 kPas, that is by 10,4 percent.

  3. Total System Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Yong Soo; Kang, Chul Hyung; Lee, Youn Myoung; Han, Ji Woong; Choi, Jong Won; Hahn, Pil Soo; Park, Jeong Hwa; Jeong, Mi Seon

    2007-06-15

    Based on the KAERI FEP list developed through the previous studies, the KAERI FEP Encyclopedia has been developed. Current version is 1.0 which includes all relevant FEPs to compose of two references and all alternative scenarios. Many interaction FEPs between scenario defining FEP(SDF) are created throughout the study. FEPs are classified into many Integrated FEP(IFEP) which eventually become the elements of the RES matrix. The FEAS program one of the component of the KAERI's CYPRUS information system is added to develop the FEP, RES, AC, AMF and finally scenarios. It assists to create transparent way to deal with assessment from the stage of the planning of the R and D to the final stage of the external audit and regulatory body review. Even though MASCOT-K and compartment analysis codes such as AMBER, GoldSim and Ecolego are excellent for TSPA they by in heritage possess a certain limitation especially to identify a proper migration cross sectional area when a relatively big component intersects with a tiny one such as a fracture. It is truly 3D phenomena in nature. MDPSA code is developed which is expected to overcome limitations in compartment models while successfully deals with natural disruptive events. The R and D target for the TSPA is to develop the sufficient scenarios and their variation cases to understand the safety of KRS in every possible aspect. For this, reference scenarios, alternative scenarios covering engineered barrier failure and natural events are developed and assessed respectively for around 100 cases. The stylized template to assess the Korean reference biosphere is developed using the AMBER. Three critical groups, agricultural, freshwater and marine water fishing groups are identified to assess the DCF following the guidelines of ICRP. Based on the QA principles of T2R3, the web based QA system is developed using the procedures in the USNRC 10CFR50 Appendix B. The QA system is combined with the PAID and FEAS to create the comprehensive

  4. Total System Performance Assessment

    International Nuclear Information System (INIS)

    Hwang, Yong Soo; Kang, Chul Hyung; Lee, Youn Myoung; Han, Ji Woong; Choi, Jong Won; Hahn, Pil Soo; Park, Jeong Hwa; Jeong, Mi Seon

    2007-06-01

    Based on the KAERI FEP list developed through the previous studies, the KAERI FEP Encyclopedia has been developed. Current version is 1.0 which includes all relevant FEPs to compose of two references and all alternative scenarios. Many interaction FEPs between scenario defining FEP(SDF) are created throughout the study. FEPs are classified into many Integrated FEP(IFEP) which eventually become the elements of the RES matrix. The FEAS program one of the component of the KAERI's CYPRUS information system is added to develop the FEP, RES, AC, AMF and finally scenarios. It assists to create transparent way to deal with assessment from the stage of the planning of the R and D to the final stage of the external audit and regulatory body review. Even though MASCOT-K and compartment analysis codes such as AMBER, GoldSim and Ecolego are excellent for TSPA they by in heritage possess a certain limitation especially to identify a proper migration cross sectional area when a relatively big component intersects with a tiny one such as a fracture. It is truly 3D phenomena in nature. MDPSA code is developed which is expected to overcome limitations in compartment models while successfully deals with natural disruptive events. The R and D target for the TSPA is to develop the sufficient scenarios and their variation cases to understand the safety of KRS in every possible aspect. For this, reference scenarios, alternative scenarios covering engineered barrier failure and natural events are developed and assessed respectively for around 100 cases. The stylized template to assess the Korean reference biosphere is developed using the AMBER. Three critical groups, agricultural, freshwater and marine water fishing groups are identified to assess the DCF following the guidelines of ICRP. Based on the QA principles of T2R3, the web based QA system is developed using the procedures in the USNRC 10CFR50 Appendix B. The QA system is combined with the PAID and FEAS to create the comprehensive

  5. Total System Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Yong Soo; Kang, Chul Hyung; Lee, Youn Myoung; Han, Ji Woong; Choi, Jong Won; Hahn, Pil Soo; Park, Jeong Hwa; Jeong, Mi Seon

    2007-06-15

    Based on the KAERI FEP list developed through the previous studies, the KAERI FEP Encyclopedia has been developed. Current version is 1.0 which includes all relevant FEPs to compose of two references and all alternative scenarios. Many interaction FEPs between scenario defining FEP(SDF) are created throughout the study. FEPs are classified into many Integrated FEP(IFEP) which eventually become the elements of the RES matrix. The FEAS program one of the component of the KAERI's CYPRUS information system is added to develop the FEP, RES, AC, AMF and finally scenarios. It assists to create transparent way to deal with assessment from the stage of the planning of the R and D to the final stage of the external audit and regulatory body review. Even though MASCOT-K and compartment analysis codes such as AMBER, GoldSim and Ecolego are excellent for TSPA they by in heritage possess a certain limitation especially to identify a proper migration cross sectional area when a relatively big component intersects with a tiny one such as a fracture. It is truly 3D phenomena in nature. MDPSA code is developed which is expected to overcome limitations in compartment models while successfully deals with natural disruptive events. The R and D target for the TSPA is to develop the sufficient scenarios and their variation cases to understand the safety of KRS in every possible aspect. For this, reference scenarios, alternative scenarios covering engineered barrier failure and natural events are developed and assessed respectively for around 100 cases. The stylized template to assess the Korean reference biosphere is developed using the AMBER. Three critical groups, agricultural, freshwater and marine water fishing groups are identified to assess the DCF following the guidelines of ICRP. Based on the QA principles of T2R3, the web based QA system is developed using the procedures in the USNRC 10CFR50 Appendix B. The QA system is combined with the PAID and FEAS to create the

  6. Introduction to radiological performance assessment

    International Nuclear Information System (INIS)

    Moss, G.

    1995-02-01

    A radiological performance assessment is conducted to provide reasonable assurance that performance objectives for low-level radioactive waste (LLW) disposal will be met. Beginning in the early stages of development, a radiological performance assessment continues through the operational phase, and is instrumental in the postclosure of the facility. Fundamental differences exist in the regulation of commercial and defense LLW, but the radiological performance assessment process is essentially the same for both. The purpose of this document is to describe that process in a concise and straightforward manner. This document focuses on radiological performance assessment as it pertains to commercial LLW disposal, but is applicable to US Department of Energy sites as well. Included are discussions on performance objectives, site characterization, and how a performance assessment is conducted. A case study is used to illustrate how the process works as a whole. A bibliography is provided to assist in locating additional information

  7. The process of performance assessment

    International Nuclear Information System (INIS)

    King, C.M.; Halford, D.K.

    1986-01-01

    An introductory review of the subject of ''Performance Assessment'' will be presented. Emphasis will be placed on the process of performance assessment from the standpoint of defining the process. Performance assessment, from evolving experience at DOE sites, has short-term and long-term subprograms, the components of which will be discussed. The role of mathematical modeling in performance assessment will be addressed including the pros and cons of current approaches. Finally, the ''system/site/technology'' issues as the focal point of this symposium will be reviewed

  8. Technology Performance Level Assessment Methodology.

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Jesse D.; Bull, Diana L; Malins, Robert Joseph; Costello, Ronan Patrick; Aurelien Babarit; Kim Nielsen; Claudio Bittencourt Ferreira; Ben Kennedy; Kathryn Dykes; Jochem Weber

    2017-04-01

    The technology performance level (TPL) assessments can be applied at all technology development stages and associated technology readiness levels (TRLs). Even, and particularly, at low TRLs the TPL assessment is very effective as it, holistically, considers a wide range of WEC attributes that determine the techno-economic performance potential of the WEC farm when fully developed for commercial operation. The TPL assessment also highlights potential showstoppers at the earliest possible stage of the WEC technology development. Hence, the TPL assessment identifies the technology independent “performance requirements.” In order to achieve a successful solution, the entirety of the performance requirements within the TPL must be considered because, in the end, all the stakeholder needs must be achieved. The basis for performing a TPL assessment comes from the information provided in a dedicated format, the Technical Submission Form (TSF). The TSF requests information from the WEC developer that is required to answer the questions posed in the TPL assessment document.

  9. Performance Assessment National Review Group

    International Nuclear Information System (INIS)

    Lieberman, J.A.; Davis, S.N.; Harleman, D.R.F.

    1985-02-01

    Performance assessment involves predicting the potential radiological impact of a nuclear waste disposal system, taking into account all of the natural and engineered components of the system. It includes the analysis and evaluation of predicted system and component performance to determine compliance with regulatory performance criteria. In the context of the nuclear waste management program, performance assessment has five major purposes: to assist in the evaluation and selection of repository sites; to guide the research, development, and testing programs; to assist in the evaluation of repository designs; to assist in the evaluation of the design and performance of engineered barriers; and to show regulatory compliance and support repository licensing. Current performance assessment methodologies are still in the developmental stage. Only the simplest of bounding calculations have produced quantitative predictions of radionuclide releases. The methodologies require considerable extension and validation before they can provide answers suitable for project decisions and licensing. 135 refs., 9 figs., 1 tab

  10. The Role of PAS Kinase in PASsing the Glucose Signal

    Directory of Open Access Journals (Sweden)

    Julianne H. Grose

    2010-06-01

    Full Text Available PAS kinase is an evolutionarily conserved nutrient responsive protein kinase that regulates glucose homeostasis. Mammalian PAS kinase is activated by glucose in pancreatic beta cells, and knockout mice are protected from obesity, liver triglyceride accumulation, and insulin resistance when fed a high-fat diet. Yeast PAS kinase is regulated by both carbon source and cell integrity stress and stimulates the partitioning of glucose toward structural carbohydrate biosynthesis. In our current model for PAS kinase regulation, a small molecule metabolite binds the sensory PAS domain and activates the enzyme. Although bona fide PAS kinase substrates are scarce, in vitro substrate searches provide putative targets for exploration.

  11. Partai Islam Se-Malaysia (PAS) dan Partai Keadilan Sejahtera (PKS) sebagai Partai Islam Pendukung Demokrasi PKS Pada Pemilu

    OpenAIRE

    Ahmad Ali Nurdin

    2015-01-01

    The article compares the achievement of Partai Islam se-Malaysia (PAS) and Partai Keadilan Sejahtera (PKS) in the latest general election held in 2013 in Malaysia and in 2014 in Indonesia. The writer finds that the political performance of PAS and PKS has indicated differently contrast results. While political electability of PAS in the 2013 Malaysia’s general election has disappointed this party, PKS has successfully proved that surveys held by a number of survey institutes—predicting that t...

  12. Waste degradation and mobilization in performance assessments for the Yucca Mountain disposal system for spent nuclear fuel and high-level radioactive waste

    International Nuclear Information System (INIS)

    Rechard, Rob P.; Stockman, Christine T.

    2014-01-01

    This paper summarizes modeling of waste degradation and mobilization in performance assessments (PAs) conducted between 1984 and 2008 to evaluate feasibility, viability, and assess compliance of a repository for spent nuclear fuel and high-level radioactive waste at Yucca Mountain in southern Nevada. As understanding of the Yucca Mountain disposal system increased, the waste degradation module, or succinctly called the source-term, evolved from initial assumptions in 1984 to results based on process modeling in 2008. In early PAs, waste degradation had significant influence on calculated behavior but as the robustness of the waste container was increased and modeling of the container degradation improved, waste degradation had much less influence in later PAs. The variation of dissolved concentrations of radionuclides progressed from simple probability distributions in early PAs to functions dependent upon water chemistry in later PAs. Also, transport modeling of radionuclides in the waste, container, and invert were added in 1995; and, colloid-facilitated transport of radionuclides was added in 1998. - Highlights: • Progression of modeling of waste degradation in performance assessments is discussed for the proposed repository at Yucca Mountain. • Progression of evaluating dissolved concentrations of radionuclides in the source-term is discussed. • Radionuclide transport modeling in the waste, container, and invert in 1995 and thereafter is discussed. • Colloid-facilitated transport in the waste, container, and invert in 1998 and thereafter is discussed

  13. Performance assessment: a peer review

    International Nuclear Information System (INIS)

    Lieberman, J.A.; Lee, W.W.L.

    1986-01-01

    This paper describes the rationale, membership, operation and major observations of the Performance Assessment National Review Group. The Group was assembled by Weston at the request of the US Department of Energy Office of Civilian Radioactive Waste Management to review performance assessment work in the US basalt, salt and tuff repository projects. The purposes were to evaluate the adequacy of the current methods, identify deficiencies, and suggest potential improvement on repository performance assessment. To perform the review, Weston retained a group of distinguished consultants who have had extensive experience in disciplines pertinent to management of radioactive wastes including mathematical modeling of fluid transport. Topics reviewed included flow and transport, source term and uncertainty analysis. While the emphasis was on methodologies, the Projects were specifically requested to show currently available results so that the way they utilized familiar methodologies could be evaluated. This paper will highlight some of the technical observations of the Group as well as some managerial and institutional issues

  14. Probability, conditional probability and complementary cumulative distribution functions in performance assessment for radioactive waste disposal

    International Nuclear Information System (INIS)

    Helton, J.C.

    1996-03-01

    A formal description of the structure of several recent performance assessments (PAs) for the Waste Isolation Pilot Plant (WIPP) is given in terms of the following three components: a probability space (S st , S st , p st ) for stochastic uncertainty, a probability space (S su , S su , p su ) for subjective uncertainty and a function (i.e., a random variable) defined on the product space associated with (S st , S st , p st ) and (S su , S su , p su ). The explicit recognition of the existence of these three components allows a careful description of the use of probability, conditional probability and complementary cumulative distribution functions within the WIPP PA. This usage is illustrated in the context of the U.S. Environmental Protection Agency's standard for the geologic disposal of radioactive waste (40 CFR 191, Subpart B). The paradigm described in this presentation can also be used to impose a logically consistent structure on PAs for other complex systems

  15. Probability, conditional probability and complementary cumulative distribution functions in performance assessment for radioactive waste disposal

    International Nuclear Information System (INIS)

    Helton, J.C.

    1996-01-01

    A formal description of the structure of several recent performance assessments (PAs) for the Waste Isolation Pilot Plant (WIPP) is given in terms of the following three components: a probability space (S st , L st , P st ) for stochastic uncertainty, a probability space (S su , L su , P su ) for subjective uncertainty and a function (i.e., a random variable) defined on the product space associated with (S st , L st , P st ) and (S su , L su , P su ). The explicit recognition of the existence of these three components allows a careful description of the use of probability, conditional probability and complementary cumulative distribution functions within the WIPP PA. This usage is illustrated in the context of the US Environmental Protection Agency's standard for the geologic disposal of radioactive waste (40 CFR 191, Subpart B). The paradigm described in this presentation can also be used to impose a logically consistent structure on PAs for other complex systems

  16. DOE site performance assessment activities

    International Nuclear Information System (INIS)

    1990-07-01

    Information on performance assessment capabilities and activities was collected from eight DOE sites. All eight sites either currently dispose of low-level radioactive waste (LLW) or plan to dispose of LLW in the near future. A survey questionnaire was developed and sent to key individuals involved in DOE Order 5820.2A performance assessment activities at each site. The sites surveyed included: Hanford Site (Hanford), Idaho National Engineering Laboratory (INEL), Los Alamos National Laboratory (LANL), Nevada Test Site (NTS), Oak Ridge National Laboratory (ORNL), Paducah Gaseous Diffusion Plant (Paducah), Portsmouth Gaseous Diffusion Plant (Portsmouth), and Savannah River Site (SRS). The questionnaire addressed all aspects of the performance assessment process; from waste source term to dose conversion factors. This report presents the information developed from the site questionnaire and provides a comparison of site-specific performance assessment approaches, data needs, and ongoing and planned activities. All sites are engaged in completing the radioactive waste disposal facility performance assessment required by DOE Order 5820.2A. Each site has achieved various degrees of progress and have identified a set of critical needs. Within several areas, however, the sites identified common needs and questions

  17. Performance assessment - risk assessment vive la differences

    International Nuclear Information System (INIS)

    Nitschke, R.L.

    1997-01-01

    In the sister worlds of radioactive waste management disposal and environmental restoration, there are two similar processes and computational approaches for determining the acceptability of the proposed activities. While similar, these two techniques can lead to confusion and misunderstanding if the differences are not recognized and appreciated. In the case of radioactive waste management, the performance assessment process is used to determine compliance with certain prescribed 'performance objectives'. These objectives are designed to ensure that the disposal of radioactive (high-level, low-level, and/or transuranic) waste will be protective of human health and the environment. The environmental link is primarily through assuring protection of the groundwater as a resource. In the case of environmental restoration, the risk assessment process is used to determine the proper remedial action response, if any, for a past hazardous waste release. The process compares the 'no action' or 'leave as is' option with both carcinogenic and noncarcinogenic values for human health to determine the need for any action and to help to help determine just what the appropriate action would need to be. The impacts to the ecological system are evaluated in a slightly, different but similar fashion. Now the common objectives between these two processes notwithstanding. There are some key and fundamental differences that need to be answered that make direct comparisons or a common approach inappropriate. Failure to recognize this can lead to confusion and misunderstanding. This can be particularly problematic when one is faced with an active disposal facility located within the boundaries of an environmental restoration site as is the case at the Idaho National Engineering Laboratory (INEL). Through a critical evaluation of the performance assessment and risk assessment processes, highlighting both similarities and differences, it is hoped that greater understanding and appreciation

  18. Power performance assessment. Final report

    International Nuclear Information System (INIS)

    Frandsen, S.

    1998-12-01

    In the increasingly commercialised wind power marketplace, the lack of precise assessment methods for the output of an investment is becoming a barrier for wider penetration of wind power. Thus, addressing this problem, the overall objectives of the project are to reduce the financial risk in investment in wind power projects by significantly improving the power performance assessment methods. Ultimately, if this objective is successfully met, the project may also result in improved tuning of the individual wind turbines and in optimisation methods for wind farm operation. The immediate, measurable objectives of the project are: To prepare a review of existing contractual aspects of power performance verification procedures of wind farms; to provide information on production sensitivity to specific terrain characteristics and wind turbine parameters by analyses of a larger number of wind farm power performance data available to the proposers; to improve the understanding of the physical parameters connected to power performance in complex environment by comparing real-life wind farm power performance data with 3D computational flow models and 3D-turbulence wind turbine models; to develop the statistical framework including uncertainty analysis for power performance assessment in complex environments; and to propose one or more procedures for power performance evaluation of wind power plants in complex environments to be applied in contractual agreements between purchasers and manufacturers on production warranties. Although the focus in this project is on power performance assessment the possible results will also be of benefit to energy yield forecasting, since the two tasks are strongly related. (au) JOULE III. 66 refs.; In Co-operation Renewable Energy System Ltd. (GB); Centre for Renewable Energy (GR); Aeronautic Research Centre (SE); National Engineering Lab. (GB); Public Power Cooperation (GR)

  19. PERFORMANCE ASSESSMENT FOR FIELD SPORTS

    Directory of Open Access Journals (Sweden)

    Christopher Carling

    2009-03-01

    Full Text Available DESCRIPTION The book covers the various sport science assessment procedures for sports such as soccer, rugby, field hockey and lacrosse. It provides detailed and clear information about laboratory and field-based methods that can be used to assess and improve both individual and team performance. PURPOSE The book aims to provide a contemporary reference tool for selection of appropriate testing procedures for sports across a range of scientific disciplines. FEATURES The text begins with a chapter on the rationales for performance assessments, the use of technology and the necessity for procedures to conform to scientific rigor, explaining the importance of test criteria. This chapter ends by emphasizing the importance of the feedback process and vital considerations for the practitioner when interpreting the data, selecting which information is most important and how to deliver this back to the athlete or coach in order to deliver a positive performance outcome. The next two chapters focus on psychological assessments with respect to skill acquisition, retention and execution providing a variety of qualitative and quantitative options, underpinned with scientific theory and contextualized in order to improve the understanding of the application of these methods to improve anticipation and decision-making to enhance game intelligence.Chapter 4 provides coverage of match analysis techniques in order to make assessments of technical, tactical and physical performances. Readers learn about a series of methodologies ranging from simplistic pen and paper options through to sophisticated technological systems with some exemplar data also provided. Chapters 5 through 7 cover the physiological based assessments, including aerobic, anaerobic and anthropometric procedures. Each chapter delivers a theoretical opening section before progressing to various assessment options and the authors make great efforts to relate to sport-specific settings. The final

  20. Methodology for NDA performance assessment

    International Nuclear Information System (INIS)

    Cuypers, M.; Franklin, M.; Guardini, S.

    1986-01-01

    In the framework of the RandD programme of the Joint Research Centre of the Commission of the European Communities, a considerable effort is being dedicated to performance assessment of NDA techniques taking account of field conditions. By taking account of field conditions is meant measurement samples of the size encountered in practice and training which allows inspectors to design cost efficient verification plans for the real situations encountered in the field. Special laboratory facilities referred to as PERLA are being constructed for this purpose. These facilities will be used for measurement experiments and for training. In this paper, performance assessment is discussed under the headings of measurement capability and in-field effectiveness. Considerable emphasis is given to the role of method specific measurement error models. The authors outline the advantages of giving statistical error models a sounder basis in the physical phenomenology of the measurement method

  1. Preliminary melter performance assessment report

    International Nuclear Information System (INIS)

    Elliott, M.L.; Eyler, L.L.; Mahoney, L.A.; Cooper, M.F.; Whitney, L.D.; Shafer, P.J.

    1994-08-01

    The Melter Performance Assessment activity, a component of the Pacific Northwest Laboratory's (PNL) Vitrification Technology Development (PVTD) effort, was designed to determine the impact of noble metals on the operational life of the reference Hanford Waste Vitrification Plant (HWVP) melter. The melter performance assessment consisted of several activities, including a literature review of all work done with noble metals in glass, gradient furnace testing to study the behavior of noble metals during the melting process, research-scale and engineering-scale melter testing to evaluate effects of noble metals on melter operation, and computer modeling that used the experimental data to predict effects of noble metals on the full-scale melter. Feed used in these tests simulated neutralized current acid waste (NCAW) feed. This report summarizes the results of the melter performance assessment and predicts the lifetime of the HWVP melter. It should be noted that this work was conducted before the recent Tri-Party Agreement changes, so the reference melter referred to here is the Defense Waste Processing Facility (DWPF) melter design

  2. Performance Assessment Institute-NV

    Energy Technology Data Exchange (ETDEWEB)

    Lombardo, Joesph [Univ. of Nevada, Las Vegas, NV (United States)

    2012-12-31

    The National Supercomputing Center for Energy and the Environment’s intention is to purchase a multi-purpose computer cluster in support of the Performance Assessment Institute (PA Institute). The PA Institute will serve as a research consortium located in Las Vegas Nevada with membership that includes: national laboratories, universities, industry partners, and domestic and international governments. This center will provide a one-of-a-kind centralized facility for the accumulation of information for use by Institutions of Higher Learning, the U.S. Government, and Regulatory Agencies and approved users. This initiative will enhance and extend High Performance Computing (HPC) resources in Nevada to support critical national and international needs in "scientific confirmation". The PA Institute will be promoted as the leading Modeling, Learning and Research Center worldwide. The program proposes to utilize the existing supercomputing capabilities and alliances of the University of Nevada Las Vegas as a base, and to extend these resource and capabilities through a collaborative relationship with its membership. The PA Institute will provide an academic setting for interactive sharing, learning, mentoring and monitoring of multi-disciplinary performance assessment and performance confirmation information. The role of the PA Institute is to facilitate research, knowledge-increase, and knowledge-sharing among users.

  3. Issues in performance assessments for disposal of US Department of Energy low-level waste

    International Nuclear Information System (INIS)

    Wood, D.E.; Wilhite, E.L.; Duggan, G.J.

    1994-12-01

    The US Department of Energy (DOE) and its contractors have long been pioneers in the field of radiological performance assessment (PA). Much effort has been expended in developing technology and acquiring data to facilitate the assessment process. This is reflected in DOE Order 5820.2A, Radioactive Waste Management Chapter III of the Order lists policy and requirements to manage the DOEs low-level waste; performance objectives for low-level waste management are stated to ensure the protection of public health and the environment. A radiological PA is also required to demonstrate compliance with the performance objectives. DOE Order 5820.2A further requires that an Oversight and Peer Review Panel be established to ensure consistency and technical quality around the DOE complex in the development and application of PA models that include site-specific geohydrology and waste composition. The DOE has also established a Performance Assessment Task Team (PATT) to integrate the activities of sites that are preparing PAs. The PATT's purpose is to recommend policy and guidance to DOE on issues that impact PAs so that the approaches taken are as consistent as possible across the DOE complex

  4. Salt site performance assessment activities

    International Nuclear Information System (INIS)

    Kircher, J.F.; Gupta, S.K.

    1983-01-01

    During this year the first selection of the tools (codes) for performance assessments of potential salt sites have been tentatively selected and documented; the emphasis has shifted from code development to applications. During this period prior to detailed characterization of a salt site, the focus is on bounding calculations, sensitivity and with the data available. The development and application of improved methods for sensitivity and uncertainty analysis is a focus for the coming years activities and the subject of a following paper in these proceedings. Although the assessments to date are preliminary and based on admittedly scant data, the results indicate that suitable salt sites can be identified and repository subsystems designed which will meet the established criteria for protecting the health and safety of the public. 36 references, 5 figures, 2 tables

  5. The DECADE performance assessment program

    International Nuclear Information System (INIS)

    Weber, B.V.; Ottinger, P.F.; Commisso, R.J.; Thompson, J.; Rowley, J.E.; Filios, P.; Babineau, M.A.

    1996-01-01

    Previous analyses of DECADE Module 1 experiments indicated significant current loss between the plasma opening switch (POS) and an electron-beam load. A program was initiated to diagnose and improve the power flow to assess the performance of a multi-module DECADE system. Power flow measurements between the POS and load indicate high vacuum flow, distributed current loss and azimuthal asymmetries. A decreased load impedance reduces the fraction of the load current flowing in vacuum. Improved plasma source symmetry reduces losses near the load for long conduction times. Increased POS impedance is required to significantly improve the power coupling to the load. (author). 6 figs., 9 refs

  6. The DECADE performance assessment program

    Energy Technology Data Exchange (ETDEWEB)

    Weber, B V; Ottinger, P F; Commisso, R J [Naval Research Lab., Washington, DC (United States). Plasma Physics Div.; Goyer, J R; Kortbawi, D [Physics International Co., Berkeley, CA (United States); Thompson, J [Maxwell Labs., San Diego, CA (United States); Rowley, J E; Filios, P [Defense Nuclear Agency, Alexandria, VA (United States); Babineau, M A [Sverdlup Technology, Tullahoma, TN (United States)

    1997-12-31

    Previous analyses of DECADE Module 1 experiments indicated significant current loss between the plasma opening switch (POS) and an electron-beam load. A program was initiated to diagnose and improve the power flow to assess the performance of a multi-module DECADE system. Power flow measurements between the POS and load indicate high vacuum flow, distributed current loss and azimuthal asymmetries. A decreased load impedance reduces the fraction of the load current flowing in vacuum. Improved plasma source symmetry reduces losses near the load for long conduction times. Increased POS impedance is required to significantly improve the power coupling to the load. (author). 6 figs., 9 refs.

  7. Performance assessment of coupled processes

    International Nuclear Information System (INIS)

    Pigford, T.H.

    1987-01-01

    The author considers all processes to be coupled. For example, a waste package heats the surrounding rock and its pore water, creating gradients in density and pressure that result in increased water flow. That process can be described as coupled, in that the flow is a consequence of heating. In a narrower sense, one speaks also of the more weakly coupled transport processes, expressed by the Onsager reciprocal relations, that state that a transport current, i.e., flux, of heat is accompanied by a small transport current of material, as evidenced in isotope separation by thermal diffusion, the Thompson effect in thermoelectricity, etc. This paper presents a performance assessment of coupled processes

  8. Designing Second Language Performance Assessments. Technical Report.

    Science.gov (United States)

    Norris, John M.; Brown, James Dean; Hudson, Thom; Yoshioka, Jim

    This technical report focuses on the decision-making potential provided by second language performance assessments. First, performance assessment is situated within the broader discussion of alternatives in language assessment and in educational assessment in general. Next, issues in performance assessment design, implementation, reliability, and…

  9. Quality assurance in performance assessments

    International Nuclear Information System (INIS)

    Maul, P.R.; Watkins, B.M.; Salter, P.; Mcleod, R

    1999-01-01

    Following publication of the Site-94 report, SKI wishes to review how Quality Assurance (QA) issues could be treated in future work both in undertaking their own Performance Assessment (PA) calculations and in scrutinising documents supplied by SKB (on planning a repository for spent fuels in Sweden). The aim of this report is to identify the key QA issues and to outline the nature and content of a QA plan which would be suitable for SKI, bearing in mind the requirements and recommendations of relevant standards. Emphasis is on issues which are specific to Performance Assessments for deep repositories for radioactive wastes, but consideration is also given to issues which need to be addressed in all large projects. Given the long time over which the performance of a deep repository system must be evaluated, the demonstration that a repository is likely to perform satisfactorily relies on the use of computer-generated model predictions of system performance. This raises particular QA issues which are generally not encountered in other technical areas (for instance, power station operations). The traceability of the arguments used is a key QA issue, as are conceptual model uncertainty, and code verification and validation; these were all included in the consideration of overall uncertainties in the Site-94 project. Additionally, issues which are particularly relevant to SKI include: How QA in a PA fits in with the general QA procedures of the organisation undertaking the work. The relationship between QA as applied by the regulator and the implementor of a repository development programme. Section 2 introduces the discussion of these issues by reviewing the standards and guidance which are available from national and international organisations. This is followed in Section 3 by a review of specific issues which arise from the Site-94 exercise. An outline procedure for managing QA issues in SKI is put forward as a basis for discussion in Section 4. It is hoped that

  10. Quality assurance in performance assessments

    Energy Technology Data Exchange (ETDEWEB)

    Maul, P.R.; Watkins, B.M.; Salter, P.; Mcleod, R [QuantiSci Ltd, Henley-on-Thames (United Kingdom)

    1999-01-01

    Following publication of the Site-94 report, SKI wishes to review how Quality Assurance (QA) issues could be treated in future work both in undertaking their own Performance Assessment (PA) calculations and in scrutinising documents supplied by SKB (on planning a repository for spent fuels in Sweden). The aim of this report is to identify the key QA issues and to outline the nature and content of a QA plan which would be suitable for SKI, bearing in mind the requirements and recommendations of relevant standards. Emphasis is on issues which are specific to Performance Assessments for deep repositories for radioactive wastes, but consideration is also given to issues which need to be addressed in all large projects. Given the long time over which the performance of a deep repository system must be evaluated, the demonstration that a repository is likely to perform satisfactorily relies on the use of computer-generated model predictions of system performance. This raises particular QA issues which are generally not encountered in other technical areas (for instance, power station operations). The traceability of the arguments used is a key QA issue, as are conceptual model uncertainty, and code verification and validation; these were all included in the consideration of overall uncertainties in the Site-94 project. Additionally, issues which are particularly relevant to SKI include: How QA in a PA fits in with the general QA procedures of the organisation undertaking the work. The relationship between QA as applied by the regulator and the implementor of a repository development programme. Section 2 introduces the discussion of these issues by reviewing the standards and guidance which are available from national and international organisations. This is followed in Section 3 by a review of specific issues which arise from the Site-94 exercise. An outline procedure for managing QA issues in SKI is put forward as a basis for discussion in Section 4. It is hoped that

  11. Improved power performance assessment methods

    Energy Technology Data Exchange (ETDEWEB)

    Frandsen, S; Antoniou, I; Dahlberg, J A [and others

    1999-03-01

    The uncertainty of presently-used methods for retrospective assessment of the productive capacity of wind farms is unacceptably large. The possibilities of improving the accuracy have been investigated and are reported. A method is presented that includes an extended power curve and site calibration. In addition, blockage effects with respect to reference wind speed measurements are analysed. It is found that significant accuracy improvements are possible by the introduction of more input variables such as turbulence and wind shear, in addition to mean wind speed and air density. Also, the testing of several or all machines in the wind farm - instead of only one or two - may provide a better estimate of the average performance. (au)

  12. Pasca-Islamisme dalam PAS: Analisis terhadap Kesan Tahalluf Siyasi

    Directory of Open Access Journals (Sweden)

    MUHAMMAD FAIZ MUKMIN ABDUL MUTALIB

    2015-12-01

    Full Text Available This study discusses the impact of post-Islamism in the Parti Islam Se-Malaysia (PAS, specifically on tahalluf siyasi (political alliance with Pakatan Rakyat (People Coalition. Post Islamism is a contemporary Islamist school of thought with regard to politics. The characteristics of post-Islamism such as toleration, participation and inclusivism has greatly influenced the modus operandi of the Islamic movement including PAS. Inclusiveness in post-Islamism had motivated PAS in having political coalition with more liberal parties such as Parti Keadilan Rakyat (PKR and Democratic Action Party (DAP. Post-Islamism as popularised by Asef Bayat was established on Western knowledge narratives, therefore such study as this should be done in order to recognise its negative impacts. To achieve this objective, the researchers used qualitative method through the process of collecting by scrutinising and analysing related data on the discourse of post-Islamism. The result of the study shows that PAS has been affected by the post-Islamism. The impact of post-Islamism in PAS however shows that PAS did not play dominant role in the Coalition throughout the political alliance. Besides, PAS also compromised a lot with its principles including its Islamic principles. Post-Islamism had also affected PAS in reducing the Muslims vote to PAS because of their support for DAP. This study therefore exposed the negative sides of post-Islamism to Islamic movement. With current development in PAS, it is hoped that this exposure will consult the Islamic movements in critically weighing their support to any kind of ideas particularly from the West.

  13. Psychometric Properties and Norms of the German ABC-Community and PAS-ADD Checklist

    Science.gov (United States)

    Zeilinger, Elisabeth L.; Weber, Germain; Haveman, Meindert J.

    2011-01-01

    Aim: The aim of the present study was to standardize and generate psychometric evidence of the German language versions of two well-established English language mental health instruments: the "Aberrant Behavior Checklist-Community" (ABC-C) and the "Psychiatric Assessment Schedule for Adults with Developmental Disabilities" (PAS-ADD) Checklist. New…

  14. Behavior model for performance assessment

    International Nuclear Information System (INIS)

    Brown-VanHoozer, S. A.

    1999-01-01

    Every individual channels information differently based on their preference of the sensory modality or representational system (visual auditory or kinesthetic) we tend to favor most (our primary representational system (PRS)). Therefore, some of us access and store our information primarily visually first, some auditorily, and others kinesthetically (through feel and touch); which in turn establishes our information processing patterns and strategies and external to internal (and subsequently vice versa) experiential language representation. Because of the different ways we channel our information, each of us will respond differently to a task--the way we gather and process the external information (input), our response time (process), and the outcome (behavior). Traditional human models of decision making and response time focus on perception, cognitive and motor systems stimulated and influenced by the three sensory modalities, visual, auditory and kinesthetic. For us, these are the building blocks to knowing how someone is thinking. Being aware of what is taking place and how to ask questions is essential in assessing performance toward reducing human errors. Existing models give predications based on time values or response times for a particular event, and may be summed and averaged for a generalization of behavior(s). However, by our not establishing a basic understanding of the foundation of how the behavior was predicated through a decision making strategy process, predicative models are overall inefficient in their analysis of the means by which behavior was generated. What is seen is the end result

  15. Behavior model for performance assessment.

    Energy Technology Data Exchange (ETDEWEB)

    Borwn-VanHoozer, S. A.

    1999-07-23

    Every individual channels information differently based on their preference of the sensory modality or representational system (visual auditory or kinesthetic) we tend to favor most (our primary representational system (PRS)). Therefore, some of us access and store our information primarily visually first, some auditorily, and others kinesthetically (through feel and touch); which in turn establishes our information processing patterns and strategies and external to internal (and subsequently vice versa) experiential language representation. Because of the different ways we channel our information, each of us will respond differently to a task--the way we gather and process the external information (input), our response time (process), and the outcome (behavior). Traditional human models of decision making and response time focus on perception, cognitive and motor systems stimulated and influenced by the three sensory modalities, visual, auditory and kinesthetic. For us, these are the building blocks to knowing how someone is thinking. Being aware of what is taking place and how to ask questions is essential in assessing performance toward reducing human errors. Existing models give predications based on time values or response times for a particular event, and may be summed and averaged for a generalization of behavior(s). However, by our not establishing a basic understanding of the foundation of how the behavior was predicated through a decision making strategy process, predicative models are overall inefficient in their analysis of the means by which behavior was generated. What is seen is the end result.

  16. 24 CFR 115.206 - Performance assessments; Performance standards.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Performance assessments; Performance standards. 115.206 Section 115.206 Housing and Urban Development Regulations Relating to Housing... AGENCIES Certification of Substantially Equivalent Agencies § 115.206 Performance assessments; Performance...

  17. Unique and cross-reactive T cell epitope peptides of the major Bahia grass pollen allergen, Pas n 1.

    Science.gov (United States)

    Etto, Tamara; de Boer, Carmela; Prickett, Sara; Gardner, Leanne M; Voskamp, Astrid; Davies, Janet M; O'Hehir, Robyn E; Rolland, Jennifer M

    2012-01-01

    Bahia grass pollen (BaGP) is a major cause of allergic rhinitis. Subcutaneous allergen-specific immunotherapy is effective for grass pollen allergy, but is unsuitable for patients with moderate to severe asthma due to the risk of anaphylaxis. T cell-reactive but IgE nonreactive peptides provide a safer treatment option. This study aimed to identify and characterize dominant CD4(+) T cell epitope peptides of the major BaGP allergen, Pas n 1. Pas n 1-specific T cell lines generated from the peripheral blood of BaGP-allergic subjects were tested for proliferative and cytokine response to overlapping 20-mer Pas n 1 peptides. Cross-reactivity to homologous peptides from Lol p 1 and Cyn d 1 of Ryegrass and Bermuda grass pollen, respectively, was assessed using Pas n 1 peptide-specific T cell clones. MHC class II restriction of Pas n 1 peptide T cell recognition was determined by HLA blocking assays and peptide IgE reactivity tested by dot blotting. Three Pas n 1 peptides showed dominant T cell reactivity; 15 of 18 (83%) patients responded to one or more of these peptides. T cell clones specific for dominant Pas n 1 peptides showed evidence of species-specific T cell reactivity as well as cross-reactivity with other group 1 grass pollen allergens. The dominant Pas n 1 T cell epitope peptides showed HLA binding diversity and were non-IgE reactive. The immunodominant T cell-reactive Pas n 1 peptides are candidates for safe immunotherapy for individuals, including those with asthma, who are allergic to Bahia and possibly other grass pollens. Copyright © 2012 S. Karger AG, Basel.

  18. Making Performance Assessments a Part of Accountability

    Science.gov (United States)

    Haun, Billy

    2018-01-01

    The purpose of this commentary is to describe recent efforts in Virginia to develop and use performance assessments, including the challenges that emerged during this process and key considerations for states that integrate performance assessment into their systems. Performance assessments can play an important role in preparing students for…

  19. Evaluation of colloid transport issues and recommendations for SKI performance assessments

    International Nuclear Information System (INIS)

    Wickham, S. M.; Bennett, D. G.; Higgo, J. J. W.

    2000-08-01

    The primary objective of this project was to develop recommendations to SKI for evaluating the potential significance of colloids in performance assessment (PA) studies by: Updating a previous review of the treatment of colloids in PA studies for radioactive waste repositories and to include information on PAs published in the period 1997-1999. We have reviewed sixteen PAs conducted in nine countries and have made the following observations: All PAs include colloid formation and colloid transport in their FEP list. Although some programmes have deferred consideration of colloidal radionuclide transport until further research has been performed, more recent PAs do account for the effects of colloids. PAs of disposal systems in which the waste canister is surrounded by a bentonite buffer do not consider the effect of colloids on the source term. These PAs assume that all colloids are filtered by the bentonite buffer and cannot escape from the near-field. PAs of disposal systems with no bentonite buffer have to account for mobilisation of radionuclides from the waste by colloids. The concentration of colloids that may form in the repository is a key uncertainty. Many PA programmes have modelled colloidal radionuclide transport in the geosphere using one-dimensional transport equations. No PA has included a comprehensive treatment of colloid transport using mechanistic modelling. Some PAs have not undertaken modelling of colloid transport in the geosphere, but have relied instead on arguments that such transport processes will be of low consequence to the performance of the disposal system. Five PAs have shown the effects of colloid transport through the geosphere to be potentially significant. For the disposal of spent nuclear fuel, SKB has developed the KBS-3 concept. For the disposal of long-lived low-level and intermediate-level radioactive waste, SKB has developed the SFL 3-5 concept. In the SFL 3-5 concept, waste is placed in underground disposal caverns and

  20. Histopathological examination of nail clippings using PAS staining (HPE-PAS): gold standard in diagnosis of Onychomycosis.

    Science.gov (United States)

    Jeelani, Shazia; Ahmed, Qazi Masood; Lanker, Audil Mohmad; Hassan, Iffat; Jeelani, Nasir; Fazili, Tawheeda

    2015-01-01

    Onychomycosis is fungal infection of one or more of the nail units. However, because fungi cause only about half of all nail dystrophies, the use of appropriate diagnostic techniques is important to ensure correct diagnosis and treatment. Aim of the present study was to compare direct microscopy, culture and HPE-PAS for diagnosis of onychomycosis by evaluating their sensitivity and various other relevant statistical parameters. A prospective, hospital-based, cross-sectional study was conducted on 216 patients with a high degree of clinical suspicion of onychomycosis. Nail specimens were evaluated using three diagnostic methods, i.e. direct microscopy using 20% Potassium hydroxide (KOH) & 40% Di-methyl-suphoxide (DMSO), culture and histopathological examination using PAS stain (HPE-PAS). Of 216 patients direct microscopy was positive in 138 (63.9%), culture in 147 (68%) and HPE-PAS in 164 patients (76%). One hundred and seventy-nine patients fitted into the criteria set for confirmed diagnosis of onychomycosis. Using this as a denominator; direct microscopy, culture and HPE-PAS had sensitivities of 77.1%, 70% and 91.6% respectively. Also, HPE-PAS showed the highest sensitivity of 94.7% in 19 cases with prediagnostic antimycotic treatment compared to direct microscopy (42.1%) or culture (57.9%). HPE-PAS shows high sensitivity for diagnosis of onychomycosis and can be considered as a gold standard in the diagnosis of onychomycosis. © 2014 Blackwell Verlag GmbH.

  1. Performance Assessments of Generic Nuclear Waste Repositories in Shale

    Science.gov (United States)

    Stein, E. R.; Sevougian, S. D.; Mariner, P. E.; Hammond, G. E.; Frederick, J.

    2017-12-01

    Simulations of deep geologic disposal of nuclear waste in a generic shale formation showcase Geologic Disposal Safety Assessment (GDSA) Framework, a toolkit for repository performance assessment (PA) whose capabilities include domain discretization (Cubit), multiphysics simulations (PFLOTRAN), uncertainty and sensitivity analysis (Dakota), and visualization (Paraview). GDSA Framework is used to conduct PAs of two generic repositories in shale. The first considers the disposal of 22,000 metric tons heavy metal of commercial spent nuclear fuel. The second considers disposal of defense-related spent nuclear fuel and high level waste. Each PA accounts for the thermal load and radionuclide inventory of applicable waste types, components of the engineered barrier system, and components of the natural barrier system including the host rock shale and underlying and overlying stratigraphic units. Model domains are half-symmetry, gridded with Cubit, and contain between 7 and 22 million grid cells. Grid refinement captures the detail of individual waste packages, emplacement drifts, access drifts, and shafts. Simulations are run in a high performance computing environment on as many as 2048 processes. Equations describing coupled heat and fluid flow and reactive transport are solved with PFLOTRAN, an open-source, massively parallel multiphase flow and reactive transport code. Additional simulated processes include waste package degradation, waste form dissolution, radioactive decay and ingrowth, sorption, solubility, advection, dispersion, and diffusion. Simulations are run to 106 y, and radionuclide concentrations are observed within aquifers at a point approximately 5 km downgradient of the repository. Dakota is used to sample likely ranges of input parameters including waste form and waste package degradation rates and properties of engineered and natural materials to quantify uncertainty in predicted concentrations and sensitivity to input parameters. Sandia National

  2. Feasibility of classification of clay minerals by using PAS

    International Nuclear Information System (INIS)

    Honda, Y; Yoshida, Y; Akiyama, Y; Nishijima, S

    2015-01-01

    After the nuclear power plant disaster, the evaluation of radioactive Cs kept in soil, especially in clay minerals and the elucidation of its movement are urgent subjects to promote decontamination. It is known that the extractable level of Cs depends on the sort of clay minerals. We tried to find the characteristics of clay minerals belonging to phillosilicate group using positron annihilation spectroscopy (PAS) and the relationship between the results of PAS and the amounts of substantially extracted Cs from the clay minerals. The results showed that each clay mineral was found to be distinguishable from other clay minerals by PAS and the extraction rate of Cs was different among those clay minerals, however the direct correlation between the results of PAS and the extraction rates of Cs was not found. (paper)

  3. 2009 Annual Summary Report for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site, Nye County, Nevada: Review of the Performance Assessments and Composite Analysis

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Management

    2010-03-15

    The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office performed an annual review of the Area 3 and Area 5 Radioactive Wate Management Site (RWMS) Performance Assessments (PAs) and Composite Analyses (CAs) in fiscal year (FY) 2009. This annual summary report presents data and conclusions from the FY 2009 review, and determines the adequacy of the PAs and CAs. Operational factors (e.g., waste forms and containers, facility design, and waste receipts), closure plans, monitoring results, and research and development (R&D) activities were reviewed to determine the adequacy of the PAs. Likewise, the environmental restoration activities at the Nevada Test Site relevant to the sources of residual radioactive material that are considered in the CAs, the land-use planning, and the results of the environmental monitoring and R&D activities were reviewed to determine the adequacy of the CAs.

  4. 2009 Annual Summary Report for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site, Nye County, Nevada: Review of the Performance Assessments and Composite Analysis

    International Nuclear Information System (INIS)

    2010-01-01

    The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office performed an annual review of the Area 3 and Area 5 Radioactive Waste Management Site (RWMS) Performance Assessments (PAs) and Composite Analyses (CAs) in fiscal year (FY) 2009. This annual summary report presents data and conclusions from the FY 2009 review, and determines the adequacy of the PAs and CAs. Operational factors (e.g., waste forms and containers, facility design, and waste receipts), closure plans, monitoring results, and research and development (R and D) activities were reviewed to determine the adequacy of the PAs. Likewise, the environmental restoration activities at the Nevada Test Site relevant to the sources of residual radioactive material that are considered in the CAs, the land-use planning, and the results of the environmental monitoring and R and D activities were reviewed to determine the adequacy of the CAs.

  5. Contractor Performance Assessment Reporting System

    Data.gov (United States)

    US Agency for International Development — CPARS is a web-based system used to input data on contractor performance. Reports from the system are used as an aid in awarding contracts to contractors that...

  6. Evaluation of colloid transport issues and recommendations for SKI performance assessments

    Energy Technology Data Exchange (ETDEWEB)

    Wickham, S. M.; Bennett, D. G.; Higgo, J. J. W. [Galson Sciences Ltd., Oakham (United Kingdom)

    2000-08-01

    The primary objective of this project was to develop recommendations to SKI for evaluating the potential significance of colloids in performance assessment (PA) studies by: Updating a previous review of the treatment of colloids in PA studies for radioactive waste repositories and to include information on PAs published in the period 1997-1999. We have reviewed sixteen PAs conducted in nine countries and have made the following observations: All PAs include colloid formation and colloid transport in their FEP list. Although some programmes have deferred consideration of colloidal radionuclide transport until further research has been performed, more recent PAs do account for the effects of colloids. PAs of disposal systems in which the waste canister is surrounded by a bentonite buffer do not consider the effect of colloids on the source term. These PAs assume that all colloids are filtered by the bentonite buffer and cannot escape from the near-field. PAs of disposal systems with no bentonite buffer have to account for mobilisation of radionuclides from the waste by colloids. The concentration of colloids that may form in the repository is a key uncertainty. Many PA programmes have modelled colloidal radionuclide transport in the geosphere using one-dimensional transport equations. No PA has included a comprehensive treatment of colloid transport using mechanistic modelling. Some PAs have not undertaken modelling of colloid transport in the geosphere, but have relied instead on arguments that such transport processes will be of low consequence to the performance of the disposal system. Five PAs have shown the effects of colloid transport through the geosphere to be potentially significant. For the disposal of spent nuclear fuel, SKB has developed the KBS-3 concept. For the disposal of long-lived low-level and intermediate-level radioactive waste, SKB has developed the SFL 3-5 concept. In the SFL 3-5 concept, waste is placed in underground disposal caverns and

  7. Performance Assessment in Courts - The Swiss Case

    Directory of Open Access Journals (Sweden)

    Andreas Lienhard

    2014-12-01

    Full Text Available Abstract Performance assessments have become commonplace in management, even in the public sector. With the increasing pressure on courts to perform while making efficient use of resources, performance assessments in the justice system are also gaining in importance. However, the need for judicial independence poses special challenges for performance assessments in courts. Against this background, this article conducts a constitutional appraisal, and contrasts the need for judicial independence with the principles governing effectiveness and efficiency, self-government and supervision, and appointment and re-appointment. A duty to guarantee justice can be derived from this that does not in principle exclude the performance assessment of judges, but even renders it essential, subject to compliance with certain requirements. In these circumstances, it seems hardly surprising that numerous countries conduct performance assessments of judges and also that various international institutions have developed principles for this purpose, a summary of which is presented – in Switzerland’s case based on a recently conducted survey. In the field of conflict between the guaranteeing justice and protecting the judiciary, the following key questions arise in particular: What is the purpose of performance assessments and what are the consequences?What is subjected to a performance assessment and what are the assessment criteria?How is performance recorded as the basis for the performance assessment?Who is subjected to a performance assessment, and must a distinction be made between judges in higher and lower courts?Who carries out the performance assessment and what methods of protecting one’s rights are available?Who should receive the results of the performance assessment?The contribution sketches out possible answers to these key questions and aims to encourage academics and practitioners to give further consideration to this subject.

  8. VISUAL ART TEACHERS AND PERFORMANCE ASSESSMENT ...

    African Journals Online (AJOL)

    Charles

    qualitative research design; an aspect of descriptive survey research aiming at ... the competence and use of assessment strategies is determined by the type of ... Visual Art Teachers and Performance Assessment Methods in Nigerian Senior ...

  9. Expert judgement in performance assessment

    International Nuclear Information System (INIS)

    Wilmot, R.D.; Galson, D.A.

    2000-01-01

    This report is a pilot study that systematically describes the various types of expert judgement that are made throughout the development of a PA, and summarizes existing tools and practices for dealing with expert judgements. The report also includes recommendations for further work in the area of expert judgement. Expert judgements can be classified in a number of ways, including classification according to why the judgements are made and according to how the judgements are made. In terms of why judgements are made, there is a broad distinction between: Judgements concerning data that are made because alternatives are not feasible; and Judgements about the conduct of a PA that are made because there are no alternative approaches for making the decision. In the case of how judgements are made, the report distinguishes between non-elicited judgements made by individuals, non-elicited judgements made by groups, and elicited judgements made by individuals or groups. These types of judgement can generally be distinguished by the extent of the associated documentation, and hence their traceability. Tools for assessing judgements vary depending on the type of judgements being examined. Key tools are peer review, an appropriate QA regime, documentation, and elicitation. Dialogue with stake holders is also identified as important in establishing whether judgements are justified in the context in which they are used. The PA process comprises a number of stages, from establishing the assessment context, through site selection and repository design, to scenario and model development and parametrisation. The report discusses how judgements are used in each of these stages, and identifies which of the tools and procedures for assessing judgements are most appropriate at each stage. Recommendations for further work include the conduct of a trial expert elicitation to gain experience in the advantages and disadvantages of this technique, the development of guidance for peer

  10. Expert judgement in performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Wilmot, R.D.; Galson, D.A. [Galson Sciences Ltd, Oakham (United Kingdom)

    2000-01-01

    This report is a pilot study that systematically describes the various types of expert judgement that are made throughout the development of a PA, and summarizes existing tools and practices for dealing with expert judgements. The report also includes recommendations for further work in the area of expert judgement. Expert judgements can be classified in a number of ways, including classification according to why the judgements are made and according to how the judgements are made. In terms of why judgements are made, there is a broad distinction between: Judgements concerning data that are made because alternatives are not feasible; and Judgements about the conduct of a PA that are made because there are no alternative approaches for making the decision. In the case of how judgements are made, the report distinguishes between non-elicited judgements made by individuals, non-elicited judgements made by groups, and elicited judgements made by individuals or groups. These types of judgement can generally be distinguished by the extent of the associated documentation, and hence their traceability. Tools for assessing judgements vary depending on the type of judgements being examined. Key tools are peer review, an appropriate QA regime, documentation, and elicitation. Dialogue with stake holders is also identified as important in establishing whether judgements are justified in the context in which they are used. The PA process comprises a number of stages, from establishing the assessment context, through site selection and repository design, to scenario and model development and parametrisation. The report discusses how judgements are used in each of these stages, and identifies which of the tools and procedures for assessing judgements are most appropriate at each stage. Recommendations for further work include the conduct of a trial expert elicitation to gain experience in the advantages and disadvantages of this technique, the development of guidance for peer

  11. Assessing school performance and motivation

    OpenAIRE

    Pavelková, Isabella; Kubíková, Katerina

    2016-01-01

    We verify the theoretical hypothesis that individual reference norm helps the development of positive achievement motivation and lowers the performance fear of pupils. The research was carried out with pupils aged 9 to 12 years. The article presents the results of the research in using reference norms with 61 teachers in connection with achievement motivation of their 1144 pupils. The research also mapped the real school situations for the teachers involved, based partly on observation during...

  12. Performance assessment in algebra learning process

    Science.gov (United States)

    Lestariani, Ida; Sujadi, Imam; Pramudya, Ikrar

    2017-12-01

    The purpose of research to describe the implementation of performance assessment on algebra learning process. The subject in this research is math educator of SMAN 1 Ngawi class X. This research includes descriptive qualitative research type. Techniques of data collecting are done by observation method, interview, and documentation. Data analysis technique is done by data reduction, data presentation, and conclusion. The results showed any indication that the steps taken by the educator in applying the performance assessment are 1) preparing individual worksheets and group worksheets, 2) preparing rubric assessments for independent worksheets and groups and 3) making performance assessments rubric to learners’ performance results with individual or groups task.

  13. Operational human performance reliability assessment (OHPRA)

    International Nuclear Information System (INIS)

    Haas, P.M.; Swanson, P.J.; Connelly, E.M.

    1993-01-01

    Operational Human Performance Reliability Assessment (OHPRA) is an approach for assessing human performance that is being developed in response to demands from modern process industries for practical and effective tools to assess and improve human performance, and therefore overall system performance and safety. The single most distinguishing feature of the approach is that is defines human performance in open-quotes operationalclose quotes terms. OHPRA is focused not on generation of human error probabilities, but on practical analysis of human performance to aid management in (1) identifying open-quotes fixableclose quotes problems and (2) providing input on the importance and nature of potential improvements. Development of the model in progress uses a unique approach for eliciting expert strategies for assessing performance. A PC-based model incorporating this expertise is planned. A preliminary version of the approach has already been used successfully to identify practical human performance problems in reactor and chemical process plant operations

  14. Performance assessment of a microsprinkler

    Directory of Open Access Journals (Sweden)

    Edivaldo Lopes Thomaz

    2014-04-01

    Full Text Available Surface hydrological processes are essential to the understanding and prediction of soil erosion. Several equipments are used to measure infiltration rate, runoff and soil loss. However, researchers build their own equipment due to the specific sites where the measurements are performed. This study evaluated the performance of a microsprinkler developed to measure the hydrological processes on unpaved rural roads. The microsprinkler is portable, lightweight, easy to operate, and also low cost. The measured parameters refer to different physical aspects of the rainfall produced as: intensity, drop size, kinetic energy and the simulation area. The microsprinkler was tested at different heights and pressures. The main results obtained: the intensity of simulated rainfall was 71.4 - 148.3 mmh-1, the drop size ranged from 0.3 to 1.2 mm (mean 0.7 mm, the kinetic energy of rainfall varied between 51 and 77% compared with a natural rainfall of similar intensity, and the simulation area had 0.28 - 0.56 m2 (mean 0.40 m2. The parameters obtained in this study are within the limit of others simulators reported in the literature.

  15. Validity of samul's paediatric appendicitis score (pas) in the diagnosis of acute appendicitis in children

    International Nuclear Information System (INIS)

    Rehman, S.; Butt, M. Q.

    2014-01-01

    Objective: To validate the paediatric appendicitis score for the diagnosis of acute appendicitis in children using histopathology as a gold standard. Study Design: Case control study. Place and Duration of Study: Military Hospital (MH) and Combined Military Hospital (CMH) Rawalpindi, Pakistan from Dec 2009 to Jul 2010. Patients and Methods: Eighty five children 1-7year old who came to our tertiary surgical department with the chief complaint of abdominal pain of less than 7 days duration were included in the study. Paediatric appendicitis score (PAS) components including fever > 380 C, anorexia, nausea/vomiting, cough/percussion/hopping tenderness, right-lower-quadrant tenderness, migration of pain, leukocytosis > 10,000 (109/1) and polymorphonuclear - neutrophilia > 7500 (109/1) were assessed and recorded on admission, but the sum was not calculated until later and the score did not play any role in the management of the patient. The diagnosis of appendicitis was made by the trainees and consultants clinically and with the aid of routine sonography of abdomen. After appendicetomies, resected specimens were sent for histopathological examination. Pre-operative PAS, histopathology report of resected appendix were endorsed on patient's performa. A two by two table was used to determine sensitivity, specificity, positive and negative predictive values and diagnostic efficacy of PAS. Results: Sensitivity of PAS was 92.16%, specificity 88.23%, positive predictive value 92.16%, negative predictive value 88.23% and the diagnostic efficacy 90.59%. Conclusion: PAS is a highly sensitive test with fair degree of specificity in diagnosing acute appendicitis in children and its routine usage may improve the diagnostic accuracy. (author)

  16. Competency Assessment Using Key Performance Indicators

    OpenAIRE

    Elena Alexandra Toader; Laura Brad

    2015-01-01

    The paper proposes a method for computing the scores of the key performance indicators resulted in the competency assessment process. The key performance indicators are estimated considering four performance levels that an IT professional can obtain at the end of the assessment process. We suggest as the best approach for estimating the performance key indicators an online questionnaire filled by 60 employees that work in IT Romanian companies. The results provide evidence that the difference...

  17. Probabilistic assessments of fuel performance

    International Nuclear Information System (INIS)

    Kelppe, S.; Ranta-Puska, K.

    1998-01-01

    The probabilistic Monte Carlo Method, coupled with quasi-random sampling, is applied for the fuel performance analyses. By using known distributions of fabrication parameters and real power histories with their randomly selected combinations, and by making a large number of ENIGMA code calculations, one expects to find out the state of the whole reactor fuel. Good statistics requires thousands of runs. A sample case representing VVER-440 reactor fuel indicates relatively low fuel temperatures and mainly athermal fission gas release if any. The rod internal pressure remains typically below 2.5 MPa, which leaves a large margin to the system pressure of 12 MPa Gap conductance, an essential parameter in the accident evaluations, shows no decrease from its start-of-life value. (orig.)

  18. Probability, conditional probability and complementary cumulative distribution functions in performance assessment for radioactive waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Helton, J.C. [Arizona State Univ., Tempe, AZ (United States)

    1996-03-01

    A formal description of the structure of several recent performance assessments (PAs) for the Waste Isolation Pilot Plant (WIPP) is given in terms of the following three components: a probability space (S{sub st}, S{sub st}, p{sub st}) for stochastic uncertainty, a probability space (S{sub su}, S{sub su}, p{sub su}) for subjective uncertainty and a function (i.e., a random variable) defined on the product space associated with (S{sub st}, S{sub st}, p{sub st}) and (S{sub su}, S{sub su}, p{sub su}). The explicit recognition of the existence of these three components allows a careful description of the use of probability, conditional probability and complementary cumulative distribution functions within the WIPP PA. This usage is illustrated in the context of the U.S. Environmental Protection Agency`s standard for the geologic disposal of radioactive waste (40 CFR 191, Subpart B). The paradigm described in this presentation can also be used to impose a logically consistent structure on PAs for other complex systems.

  19. Sandia National Laboratories performance assessment methodology for long-term environmental programs : the history of nuclear waste management.

    Energy Technology Data Exchange (ETDEWEB)

    Marietta, Melvin Gary; Anderson, D. Richard; Bonano, Evaristo J.; Meacham, Paul Gregory (Raytheon Ktech, Albuquerque, NM)

    2011-11-01

    Sandia National Laboratories (SNL) is the world leader in the development of the detailed science underpinning the application of a probabilistic risk assessment methodology, referred to in this report as performance assessment (PA), for (1) understanding and forecasting the long-term behavior of a radioactive waste disposal system, (2) estimating the ability of the disposal system and its various components to isolate the waste, (3) developing regulations, (4) implementing programs to estimate the safety that the system can afford to individuals and to the environment, and (5) demonstrating compliance with the attendant regulatory requirements. This report documents the evolution of the SNL PA methodology from inception in the mid-1970s, summarizing major SNL PA applications including: the Subseabed Disposal Project PAs for high-level radioactive waste; the Waste Isolation Pilot Plant PAs for disposal of defense transuranic waste; the Yucca Mountain Project total system PAs for deep geologic disposal of spent nuclear fuel and high-level radioactive waste; PAs for the Greater Confinement Borehole Disposal boreholes at the Nevada National Security Site; and PA evaluations for disposal of high-level wastes and Department of Energy spent nuclear fuels stored at Idaho National Laboratory. In addition, the report summarizes smaller PA programs for long-term cover systems implemented for the Monticello, Utah, mill-tailings repository; a PA for the SNL Mixed Waste Landfill in support of environmental restoration; PA support for radioactive waste management efforts in Egypt, Iraq, and Taiwan; and, most recently, PAs for analysis of alternative high-level radioactive waste disposal strategies including repositories deep borehole disposal and geologic repositories in shale and granite. Finally, this report summarizes the extension of the PA methodology for radioactive waste disposal toward development of an enhanced PA system for carbon sequestration and storage systems

  20. Performance Assessment of Mergers and Acquisitions

    DEFF Research Database (Denmark)

    Wang, Daojuan; Moini, Hamid

    2012-01-01

    on the performance measures and benchmarks adopted in M&A research field and the relevant empirical results. We find that the definitions of performance varied in terms of accounting, financial, operational and perceptual metrics. And performance assessment is sensitive to the definition of performance, methodology......Corporate mergers and acquisitions (M&As) have been increasing popular during these decades. However, a majority of research show failure rate (40% - 80%) has not significantly changed. This “success paradox” triggers us to reflect on performance assessment of M&As: how the performance of M...

  1. 2008 Annual Summary Report for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site, Nye County, Nevada: Review of the Performance Assessments and Composite Analyses

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Management

    2009-03-30

    The Maintenance Plan for the Performance Assessments and Composite Analyses for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site requires an annual review to assess the adequacy of the Performance Assessments (PAs) and Composite Analyses (CAs) for each of the facilities, with the results submitted annually to U.S. Department of Energy (DOE) Headquarters. The Disposal Authorization Statements for the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) also require that such reviews be made and that secondary or minor unresolved issues be tracked and addressed as part of the maintenance plan. The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) performed an annual review in fiscal year (FY) 2008 by evaluating operational factors and research results that impact the continuing validity of the PAs and CAs. This annual summary report presents data and conclusions from the FY 2008 review, and determines the adequacy of the PAs and CAs. Operational factors (e.g., waste forms and containers, facility design, and waste receipts), closure plans, monitoring results, and research and development (R&D) activities were reviewed to determine the adequacy of the PAs. Likewise, the environmental restoration activities at the Nevada Test Site relevant to the sources of residual radioactive material that are considered in the CAs, the land-use planning, and the results of the environmental monitoring and R&D activities were reviewed to determine the adequacy of the CAs.

  2. 2008 Annual Summary Report for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site, Nye County, Nevada: Review of the Performance Assessments and Composite Analyses

    International Nuclear Information System (INIS)

    2009-01-01

    The Maintenance Plan for the Performance Assessments and Composite Analyses for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site requires an annual review to assess the adequacy of the Performance Assessments (PAs) and Composite Analyses (CAs) for each of the facilities, with the results submitted annually to U.S. Department of Energy (DOE) Headquarters. The Disposal Authorization Statements for the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) also require that such reviews be made and that secondary or minor unresolved issues be tracked and addressed as part of the maintenance plan. The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) performed an annual review in fiscal year (FY) 2008 by evaluating operational factors and research results that impact the continuing validity of the PAs and CAs. This annual summary report presents data and conclusions from the FY 2008 review, and determines the adequacy of the PAs and CAs. Operational factors (e.g., waste forms and containers, facility design, and waste receipts), closure plans, monitoring results, and research and development (R and D) activities were reviewed to determine the adequacy of the PAs. Likewise, the environmental restoration activities at the Nevada Test Site relevant to the sources of residual radioactive material that are considered in the CAs, the land-use planning, and the results of the environmental monitoring and R and D activities were reviewed to determine the adequacy of the CAs.

  3. The Effects of Performance-Based Assessment Criteria on Student Performance and Self-Assessment Skills

    Science.gov (United States)

    Fastre, Greet Mia Jos; van der Klink, Marcel R.; van Merrienboer, Jeroen J. G.

    2010-01-01

    This study investigated the effect of performance-based versus competence-based assessment criteria on task performance and self-assessment skills among 39 novice secondary vocational education students in the domain of nursing and care. In a performance-based assessment group students are provided with a preset list of performance-based…

  4. Improving Site-Specific Radiological Performance Assessments - 13431

    International Nuclear Information System (INIS)

    Tauxe, John; Black, Paul; Catlett, Kate; Lee, Robert; Perona, Ralph; Stockton, Tom; Sully, Mike

    2013-01-01

    An improved approach is presented for conducting complete and defensible radiological site-specific performance assessments (PAs) to support radioactive waste disposal decisions. The basic tenets of PA were initiated some thirty years ago, focusing on geologic disposals and evaluating compliance with regulations. Some of these regulations were inherently probabilistic (i.e., addressing uncertainty in a quantitative fashion), such as the containment requirements of the U.S. Environmental Protection Agency's (EPA's) 40 CFR 191, Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes, Chap. 191.13 [1]. Methods of analysis were developed to meet those requirements, but at their core early PAs used 'conservative' parameter values and modeling approaches. This limited the utility of such PAs to compliance evaluation, and did little to inform decisions about optimizing disposal, closure and long-term monitoring and maintenance, or, in general, maintaining doses 'as low as reasonably achievable' (ALARA). This basic approach to PA development in the United States was employed essentially unchanged through the end of the 20. century, principally by the U.S. Department of Energy (DOE). Performance assessments developed in support of private radioactive waste disposal operations, regulated by the U.S. Nuclear Regulatory Commission (NRC) and its agreement states, were typically not as sophisticated. Discussion of new approaches to PA is timely, since at the time of this writing, the DOE is in the midst of revising its Order 435.1, Radioactive Waste Management [2], and the NRC is revising 10 CFR 61, Licensing Requirements for Land Disposal of Radioactive Waste [3]. Over the previous decade, theoretical developments and improved computational technology have provided the foundation for integrating decision analysis (DA) concepts and objective-focused thinking, plus a Bayesian approach to

  5. Improving Site-Specific Radiological Performance Assessments - 13431

    Energy Technology Data Exchange (ETDEWEB)

    Tauxe, John; Black, Paul; Catlett, Kate; Lee, Robert; Perona, Ralph; Stockton, Tom; Sully, Mike [Neptune and Company, Inc., Los Alamos, New Mexico 87544 (United States)

    2013-07-01

    An improved approach is presented for conducting complete and defensible radiological site-specific performance assessments (PAs) to support radioactive waste disposal decisions. The basic tenets of PA were initiated some thirty years ago, focusing on geologic disposals and evaluating compliance with regulations. Some of these regulations were inherently probabilistic (i.e., addressing uncertainty in a quantitative fashion), such as the containment requirements of the U.S. Environmental Protection Agency's (EPA's) 40 CFR 191, Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes, Chap. 191.13 [1]. Methods of analysis were developed to meet those requirements, but at their core early PAs used 'conservative' parameter values and modeling approaches. This limited the utility of such PAs to compliance evaluation, and did little to inform decisions about optimizing disposal, closure and long-term monitoring and maintenance, or, in general, maintaining doses 'as low as reasonably achievable' (ALARA). This basic approach to PA development in the United States was employed essentially unchanged through the end of the 20. century, principally by the U.S. Department of Energy (DOE). Performance assessments developed in support of private radioactive waste disposal operations, regulated by the U.S. Nuclear Regulatory Commission (NRC) and its agreement states, were typically not as sophisticated. Discussion of new approaches to PA is timely, since at the time of this writing, the DOE is in the midst of revising its Order 435.1, Radioactive Waste Management [2], and the NRC is revising 10 CFR 61, Licensing Requirements for Land Disposal of Radioactive Waste [3]. Over the previous decade, theoretical developments and improved computational technology have provided the foundation for integrating decision analysis (DA) concepts and objective-focused thinking, plus

  6. [Development of the Parenting in Adolescence Scale (PAS)].

    Science.gov (United States)

    Utsumi, Shoka

    2013-08-01

    The present study developed the Parenting in Adolescence Scale (PAS) based on the three-factor model of parenting by Schaefer (1965), and examined its psychometric properties. Adolescents (n = 103 junior high, 273 high school and 667 university students) completed a questionnaire. Exploratory factor analysis identified three distinct factors labeled "Acceptance" (6 items), "Psychological control" (6 items) and "Parental monitoring" (3 items). Confirmatory factor analysis demonstrated the stability of the factor structure with adequate goodness of fit indices. The three subscales of PAS had adequate internal consistency and satisfactory test-retest reliability. The three scales also correlated significantly with measures of adolescent conduct problems, peer problems, risk-taking experience, prosocial behavior, self-esteem, and another parenting scale, which indicated construct and concurrent validity. The practical use of the PAS was discussed.

  7. Review of SR 97 performance assessment

    International Nuclear Information System (INIS)

    Glynn, P.D.

    2000-01-01

    This review has identified many technical problems in the SR 97 performance assessment. The general impression of this reviewer is that SKB has been disingenuous in its performance assessment effort. It has not cited important differences of opinion with its own views. Furthermore, there are many inconsistencies in the SR 97 report that all together leave the impression that there are many more uncertainties in the SR 97 performance assessment than SKB would perhaps care to admit. Additionally, despite SKB's statements to the contrary, many of the analyses conducted for the SR 97 performance assessment can be clearly shown not to have been based on 'conservative' assumptions. Finally, SKB has made little effort to consider possible coupling effects between their different scenarios in SR 97. This is a serious flaw in the SR 97 performance assessment. The comments in this review should not be taken to imply that the KBS-3 nuclear waste disposal method will not be able to meet the safety and radiation protection requirements which SKI and SSI have specified in recent years. Instead, my conclusion is simply that the SR 97 performance assessment of the KBS-3 method would have been more believable had it been based on a forthright and comprehensive discussion of facts, uncertainties and opinions, and on a more conservative choice of assumptions. As it stands, the SR 97 performance assessment is not very credible

  8. Maintenance Plan for the Performance Assessments and Composite Analyses for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site

    International Nuclear Information System (INIS)

    V. Yucel

    2002-01-01

    U.S. Department of Energy (DOE) Order 435.1 requires that performance assessments (PAs) and composite analyses (CAs) for low-level waste (LLW) disposal facilities be maintained by the field offices. This plan describes the activities to be performed in maintaining the Performance Assessment (PA) and Composite Analysis (CA) for the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS). The Disposal Authorization Statement (DAS) for the continuing operations of a LLW facility at the DOE complex specifies the conditions for operations based on approval of a PA and CA, and requires the facility to implement a maintenance program to assure that these conditions will remain protective of the public health and the environment in the future. The goal of the maintenance program is to provide that assurance. The maintenance process is an iterative one in which changing conditions may result in a revision of PA and CA; the revised PA and CA may impose a different set of conditions for facility operation, closure, and postclosure. The maintenance process includes managing uncertainty, performing annual reviews, submitting annual summary reports to DOE Headquarters (DOE/HQ), carrying out special analyses, and revising the PAs and CAs, if necessary. Management of uncertainty is an essential component of the maintenance program because results of the original PAs and CAs are understood to be based on uncertain assumptions about the conceptual models; the mathematical models and parameters; and the future state of the lands, disposal facilities, and human activities. The annual reviews for the PAs include consideration of waste receipts, facility specific factors, results of monitoring, and results of research and development (R and D) activities. Likewise, results of ongoing R and D, changes in land-use planning, new information on known sources of residual radioactive materials, and identification of new sources may warrant an evaluation to

  9. Return on investment of advanced practice medical degrees: NPs vs. PAs.

    Science.gov (United States)

    Craig, Christopher K; Holmes, James H; Carter, Jeffery E

    2017-06-01

    As the United States faces a predicted physician shortage over the next 2 decades, physician assistants (PAs) and NPs are expected to fill the void. At the same time, because education is expensive, student loan and tuition increases have many potential applicants assessing differences in reimbursement and wondering about their return on investment (ROI). An analysis compared PA and NP salaries by incorporating national salary data, federal income tax, and student loans for a comparative analysis of each career pathway. Salaries were abstracted from the 2012 Bureau of Labor Statistics database. The net present value (NPV) of PA and NP salaries was calculated with a 5% discount rate. Principal and interest for student loans was calculated at a 6% interest fixed-rate loan over 30 years. NPVs were then compared with projected ROI at retirement age. Relative career values were also given to each career choice, based on a retirement age of 65 years, which translates to about 41 years of employment for both PAs and NPs. PAs' and NPs' educational loans both equalled $129,484 on total repayment. The median annual salary of a PA was $90,930 and $89,960 for an NP. PA data yielded a 5% NPV of $781,323 compared with $764,348 for NPs. Of note, the 5% NPV of a 4-year nursing degree is $728,436. PAs have a slightly higher ROI compared with NPs. These findings may change due to adjustments in nursing training models. Many PA programs allow matriculation immediately after obtaining a bachelor's degree. NP schools often require nursing experience before entering their program. Some schools are considering an accelerated NP program, allowing immediate matriculation after obtaining a bachelor's degree. Because many NP programs have become doctoral degrees, the increased duration of training, higher tuition, and fewer years worked before retirement lower the overall NP ROI. A similar reduction in ROI was considered marginal in PAs who attend residency programs-though these programs are

  10. Ceux-ci ne sont pas : [luuletused] / Kalju Kruusa

    Index Scriptorium Estoniae

    Kruusa, Kalju, pseud., 1973-

    2003-01-01

    Sisu: Ceux-ci ne sont pas ; Köögivahet ; "Taara..." ; "Pakane pistab pisikesi ..." ; "Meri on kaet mattklaasiga ; Pydemise päivil ; "Toas muusika mängib ..." ; "Jäin juustu imetlema ; "Mu elu on mustikas ..." ; Hingepidetus ; ŁNo me gusta la cocina

  11. IkPas : Een definitieve breuk met het verleden?

    NARCIS (Netherlands)

    Bovens, R.H.L.M.; Schuitema, A.; P.M., Schmidt

    2017-01-01

    IkPas (‘No Thanks’) is a Dutch 30 or 40 days temporary alcohol abstinence challenge, aiming at alcohol awareness and changing habitual drinking behavior. Former effect evaluations show a significant decrease in alcohol use measured 6 months after finishing the challenge. In this study the authors

  12. VISUAL ART TEACHERS AND PERFORMANCE ASSESSMENT ...

    African Journals Online (AJOL)

    Charles

    Senior Secondary school visual art teachers constituted the sample of this ... and Performance Assessment Methods in Nigerian Senior Secondary Schools – Bello .... definition includes knowledge, skills, attitudes, metacognition and strategic ...

  13. Balanced ScoreCard Y las Normas de Integración PAS 99:2006

    Directory of Open Access Journals (Sweden)

    Soler González, Rafael H.

    2013-12-01

    Full Text Available For the development of this work the authors used the Norton & Kaplan recommendations for the implementation of the Balanced Scorecard (BSC, and novel diagnostic tools as SISTRAT, strategy maps software for LINUX UBUNTU DC Map.xls and development of Box Mando. Once the BSC was implemented, a longitudinal study of data in the scorecard was carried out in order to analyze to what extent the implementation of the BSC in the Design and Engineering Company (EDIN coincided with the seven principles of integration standards PAS 99:2006. For this comparison Hamming´s relative distances were used as a measurement tool. Respective analyzes were performed to the extent that the relative distances were declining which showed that the BSC implemented in EDIN was consistent with PAS 99:2006.

  14. Enabling performance skills: Assessment in engineering education

    Science.gov (United States)

    Ferrone, Jenny Kristina

    Current reform in engineering education is part of a national trend emphasizing student learning as well as accountability in instruction. Assessing student performance to demonstrate accountability has become a necessity in academia. In newly adopted criterion proposed by the Accreditation Board for Engineering and Technology (ABET), undergraduates are expected to demonstrate proficiency in outcomes considered essential for graduating engineers. The case study was designed as a formative evaluation of freshman engineering students to assess the perceived effectiveness of performance skills in a design laboratory environment. The mixed methodology used both quantitative and qualitative approaches to assess students' performance skills and congruency among the respondents, based on individual, team, and faculty perceptions of team effectiveness in three ABET areas: Communications Skills. Design Skills, and Teamwork. The findings of the research were used to address future use of the assessment tool and process. The results of the study found statistically significant differences in perceptions of Teamwork Skills (p performance skills, such as teamwork, among freshman engineering students; (2) incorporate feedback into the learning process; (3) strengthen the assessment process with a follow-up plan that specifically targets performance skill deficiencies, and (4) integrate the assessment instrument and practice with ongoing curriculum development. The findings generated by this study provides engineering departments engaged in assessment activity, opportunity to reflect, refine, and develop their programs as it continues. It also extends research on ABET competencies of engineering students in an under-investigated topic of factors correlated with team processes, behavior, and student learning.

  15. Personality, Assessment Methods and Academic Performance

    Science.gov (United States)

    Furnham, Adrian; Nuygards, Sarah; Chamorro-Premuzic, Tomas

    2013-01-01

    This study examines the relationship between personality and two different academic performance (AP) assessment methods, namely exams and coursework. It aimed to examine whether the relationship between traits and AP was consistent across self-reported versus documented exam results, two different assessment techniques and across different…

  16. Assessing Vocal Performances Using Analytical Assessment: A Case Study

    Science.gov (United States)

    Gynnild, Vidar

    2016-01-01

    This study investigated ways to improve the appraisal of vocal performances within a national academy of music. Since a criterion-based assessment framework had already been adopted, the conceptual foundation of an assessment rubric was used as a guide in an action research project. The group of teachers involved wanted to explore thinking…

  17. Physician Performance Assessment: Prevention of Cardiovascular Disease

    Science.gov (United States)

    Lipner, Rebecca S.; Weng, Weifeng; Caverzagie, Kelly J.; Hess, Brian J.

    2013-01-01

    Given the rising burden of healthcare costs, both patients and healthcare purchasers are interested in discerning which physicians deliver quality care. We proposed a methodology to assess physician clinical performance in preventive cardiology care, and determined a benchmark for minimally acceptable performance. We used data on eight…

  18. Assessing irrigation performance by using remote sensing

    NARCIS (Netherlands)

    Bandara, K.M.P.S.

    2006-01-01

    Keywords: Performance indicators, performance assessment, diagnostic approach, SEBAL, target level, grain yield, water productivity, error estimation, spatio-temporal resolution.

    In

  19. Performing the lockout/tagout risk assessment.

    Science.gov (United States)

    Wallace, W Jon

    2007-03-01

    Lockout/tagout provides the greatest level routine, repetitive, and integral to the production process, a risk assessment should be performed. If the task performed poses an unacceptable risk, acceptable risk reduction methods should be implemented to reduce the risk to acceptable levels.

  20. The PAS fold: A redefinition of the PAS domain based upon structural prediction. A large-scale homology modelling study

    NARCIS (Netherlands)

    Hefti, M.H.; Francoijs, C.J.J.; Vries, de S.C.; Dixon, R.; Vervoort, J.J.M.

    2004-01-01

    In the postgenomic era it is essential that protein sequences are annotated correctly in order to help in the assignment of their putative functions. Over 1300 proteins in current protein sequence databases are predicted to contain a PAS domain based upon amino acid sequence alignments. One of the

  1. Gamma camera performance: technical assessment protocol

    International Nuclear Information System (INIS)

    Bolster, A.A.; Waddington, W.A.

    1996-01-01

    This protocol addresses the performance assessment of single and dual headed gamma cameras. No attempt is made to assess the performance of any associated computing systems. Evaluations are usually performed on a gamma camera commercially available within the United Kingdom and recently installed at a clinical site. In consultation with the manufacturer, GCAT selects the site and liaises with local staff to arrange a mutually convenient time for assessment. The manufacturer is encouraged to have a representative present during the evaluation. Three to four days are typically required for the evaluation team to perform the necessary measurements. When access time is limited, the team will modify the protocol to test the camera as thoroughly as possible. Data are acquired on the camera's computer system and are subsequently transferred to the independent GCAT computer system for analysis. This transfer from site computer to the independent system is effected via a hardware interface and Interfile data transfer. (author)

  2. Gamma camera performance: technical assessment protocol

    Energy Technology Data Exchange (ETDEWEB)

    Bolster, A.A. [West Glasgow Hospitals NHS Trust, London (United Kingdom). Dept. of Clinical Physics; Waddington, W.A. [University College London Hospitals NHS Trust, London (United Kingdom). Inst. of Nuclear Medicine

    1996-12-31

    This protocol addresses the performance assessment of single and dual headed gamma cameras. No attempt is made to assess the performance of any associated computing systems. Evaluations are usually performed on a gamma camera commercially available within the United Kingdom and recently installed at a clinical site. In consultation with the manufacturer, GCAT selects the site and liaises with local staff to arrange a mutually convenient time for assessment. The manufacturer is encouraged to have a representative present during the evaluation. Three to four days are typically required for the evaluation team to perform the necessary measurements. When access time is limited, the team will modify the protocol to test the camera as thoroughly as possible. Data are acquired on the camera`s computer system and are subsequently transferred to the independent GCAT computer system for analysis. This transfer from site computer to the independent system is effected via a hardware interface and Interfile data transfer. (author).

  3. Noninvasive glucose sensing in scattering media using OCT, PAS, and TOF techniques

    Science.gov (United States)

    Alarousu, Erkki; Hast, Jukka T.; Kinnunen, Matti T.; Kirillin, Mikhail Y.; Myllyla, Risto A.; Plucinski, Jerzy; Popov, Alexey P.; Priezzhev, Alexander V.; Prykari, Tuukka; Saarela, Juha; Zhao, Zuomin

    2004-08-01

    In this paper, optical measurement techniques, which enable non-invasive measurement, are superimposed to glucose sensing in scattering media. Used measurement techniques are Optical Coherence Tomography (OCT), Photoacoustic spectroscopy (PAS) and laser pulse Time-of-Flight (TOF) measurement using a streak camera. In parallel with measurements, a Monte-Carlo (MC) simulation models have been developed. Experimental in vitro measurements were performed using Intralipid fat emulsion as a tissue simulating phantom for OCT and TOF measurements. In PAS measurements, a pork meat was used as a subject but also preliminary in vivo measurements were done. OCT measurement results show that the slope of the OCT signal's envelope changes as a function of glucose content in the scattering media. TOF measurements show that the laser pulse full width of half maximum (FWHM) changes a little as function of glucose content. An agreement with MC-simulations and measurements with Intralipid was also found. Measurement results of PAS technique show that changes in glucose content in the pork meat tissue can be measured. In vivo measurements with a human volunteer show that other factors such as physiological change, blood circulation and body temperature drift may interfere the PA response of glucose.

  4. 5th Total System Performance Assessment Workshop

    International Nuclear Information System (INIS)

    Hwang, Yong Soo; Lee, Youn Myoung; Kang, Chul Hyung; Lee, Sung Ho

    2009-07-01

    Research items on safety assessment of high-level waste repository have been proposed by external invited experts outside KAERI and discussed extensively during the annual 5th performance assessment workshop prepared by safety assessment group in KAERI. This could be useful to set up R and D plans necessary for the next phase of mid- and long-term reaserch area regarding the safety assessment of high-level waste repository. Through the research and the presentation, HLW-related research and development area including such specific research items as current status of HLW safety assessment research, current requirement for the licensing of the repository system, priority on research area, data base building for the safety assessment, source-term modeling as well as safety case, among many others, have been discussed and summarized

  5. Small animal PET: aspects of performance assessment

    International Nuclear Information System (INIS)

    Weber, Simone; Bauer, Andreas

    2004-01-01

    Dedicated small animal positron emission tomography (PET) systems are increasingly prevalent in industry (e.g. for preclinical drug development) and biological research. Such systems permit researchers to perform animal studies of a longitudinal design characterised by repeated measurements in single animals. With the advent of commercial systems, scanners have become readily available and increasingly popular. As a consequence, technical specifications are becoming more diverse, making scanner systems less broadly applicable. The investigator has, therefore, to make a decision regarding which type of scanner is most suitable for the intended experiments. This decision should be based on gantry characteristics and the physical performance. The first few steps have been taken towards standardisation of the assessment of performance characteristics of dedicated animal PET systems, though such assessment is not yet routinely implemented. In this review, we describe current methods of evaluation of physical performance parameters of small animal PET scanners. Effects of methodologically different approaches on the results are assessed. It is underscored that particular attention has to be paid to spatial resolution, sensitivity, scatter fraction and count rate performance. Differences in performance measurement methods are described with regard to commercially available systems, namely the Concorde MicroPET systems P4 and R4 and the quad-HIDAC. Lastly, consequences of differences in scanner performance parameters are rated with respect to applications of small animal PET. (orig.)

  6. Procedures and acceptance criteria for PAS-1 cask inspections

    International Nuclear Information System (INIS)

    Mercado, J.E.

    1998-01-01

    The procedures and acceptance criteria that comprise this document were prepared to support a one-time test to certify two PAS-1 casks in accordance with US Department of Energy Certificate of Compliance US A/9184/B(U), which was issued in 1998. The specific inspections addressed in this document are the visual weld inspection and a dimensional inspection of the primary containment vessel

  7. Performance success from self-assessments

    International Nuclear Information System (INIS)

    Hughes, G.

    1996-01-01

    This paper provides information on and successes of self-assessments completed at the Callaway plant. It stresses the vital needs and substantial benefits from these continual self-improvement efforts. The Callaway plant staff use a variety of methods and techniques to do self-assessments with the focus on performance outcomes. Self-assessments help Callaway focus on the priority issues and direct resources properly. Callaway's success has been due to this learning culture. The Callaway plant is a Westinghouse four-loop plant in the state of Missouri and has been operational since 1984

  8. Assessing the Performance of Natural Resource Systems

    Directory of Open Access Journals (Sweden)

    Bruce Campbell

    2002-01-01

    Full Text Available Assessing the performance of management is central to natural resource management, in terms of improving the efficiency of interventions in an adaptive-learning cycle. This is not simple, given that such systems generally have multiple scales of interaction and response; high frequency of nonlinearity, uncertainty, and time lags; multiple stakeholders with contrasting objectives; and a high degree of context specificity. The importance of bounding the problem and preparing a conceptual model of the system is highlighted. We suggest that the capital assets approach to livelihoods may be an appropriate organizing principle for the selection of indicators of system performance. In this approach, five capital assets are recognized: physical, financial, social, natural, and human. A number of principles can be derived for each capital asset; indicators for assessing system performance should cover all of the principles. To cater for multiple stakeholders, participatory selection of indicators is appropriate, although when cross-site comparability is required, some generic indicators are suitable. Because of the high degree of context specificity of natural resource management systems, a typology of landscapes or resource management domains may be useful to allow extrapolation to broader systems. The problems of nonlinearities, uncertainty, and time lags in natural resource management systems suggest that systems modeling is crucial for performance assessment, in terms of deriving "what would have happened anyway" scenarios for comparison to the measured trajectory of systems. Given that a number of indicators are necessary for assessing performance, the question becomes whether these can be combined to give an integrative assessment. We explore five possible approaches: (1 simple additive index, as used for the Human Development Index; (2 derived variables (e.g., principal components as the indices of performance; (3 two-dimensional plots of

  9. Dehydration: physiology, assessment, and performance effects.

    Science.gov (United States)

    Cheuvront, Samuel N; Kenefick, Robert W

    2014-01-01

    This article provides a comprehensive review of dehydration assessment and presents a unique evaluation of the dehydration and performance literature. The importance of osmolality and volume are emphasized when discussing the physiology, assessment, and performance effects of dehydration. The underappreciated physiologic distinction between a loss of hypo-osmotic body water (intracellular dehydration) and an iso-osmotic loss of body water (extracellular dehydration) is presented and argued as the single most essential aspect of dehydration assessment. The importance of diagnostic and biological variation analyses to dehydration assessment methods is reviewed and their use in gauging the true potential of any dehydration assessment method highlighted. The necessity for establishing proper baselines is discussed, as is the magnitude of dehydration required to elicit reliable and detectable osmotic or volume-mediated compensatory physiologic responses. The discussion of physiologic responses further helps inform and explain our analysis of the literature suggesting a ≥ 2% dehydration threshold for impaired endurance exercise performance mediated by volume loss. In contrast, no clear threshold or plausible mechanism(s) support the marginal, but potentially important, impairment in strength, and power observed with dehydration. Similarly, the potential for dehydration to impair cognition appears small and related primarily to distraction or discomfort. The impact of dehydration on any particular sport skill or task is therefore likely dependent upon the makeup of the task itself (e.g., endurance, strength, cognitive, and motor skill). © 2014 American Physiological Society.

  10. Performance assessment of gamma cameras. Part 1

    International Nuclear Information System (INIS)

    Elliot, A.T.; Short, M.D.; Potter, D.C.; Barnes, K.J.

    1980-11-01

    The Dept. of Health and Social Security and the Scottish Home and Health Dept. has sponsored a programme of measurements of the important performance characteristics of 15 leading types of gamma cameras providing a routine radionuclide imaging service in hospitals throughout the UK. Measurements have been made of intrinsic resolution, system resolution, non-uniformity, spatial distortion, count rate performance, sensitivity, energy resolution and shield leakage. The main aim of this performance assessment was to provide sound information to the NHS to ease the task of those responsible for the purchase of gamma cameras. (U.K.)

  11. Performance Assessment Position Paper: Time for Compliance

    International Nuclear Information System (INIS)

    Wilhite, E.L.

    2003-01-01

    This study lays out the historical development of the time frame for a low-level waste disposal facility to demonstrate compliance with the DOE performance objectives and requirements. The study recommends that 1,000 years should be used as the time for compliance for all of the performance objectives and requirements (i.e., for the all-pathways, air pathway, radon emanation, water resource protection and inadvertent intruder analyses) for all low-level waste disposal facility performance assessments at the Savannah River Site

  12. Assessing the Performance of Business Unit Managers

    NARCIS (Netherlands)

    Bouwens, J.F.M.G.; van Lent, L.A.G.M.

    2006-01-01

    Using a sample of 140 managers, we investigate the use of various performance metrics in determining the periodic assessment, bonus decisions, and career paths of business unit managers.We show that the weight on accounting return measures is associated with the authority of these managers, and we

  13. The Visible Hand of Research Performance Assessment

    Science.gov (United States)

    Hamann, Julian

    2016-01-01

    Far from allowing a governance of universities by the invisible hand of market forces, research performance assessments do not just measure differences in research quality, but yield themselves visible symptoms in terms of a stratification and standardization of disciplines. The article illustrates this with a case study of UK history departments…

  14. Performance assessment of indigenously developed FBG strain ...

    Indian Academy of Sciences (India)

    Use of FBG sensors for real time health monitoring of various civil engineering structures is well-established in western world since last decade, whereas in the Indian context this technology is still in a nascent stage. In this paper, performance assessment of indigenously developed FBG sensors for the application of health ...

  15. An overview of performance assessment methodology

    International Nuclear Information System (INIS)

    Hongnian Jow

    2010-01-01

    The definition of performance assessment (PA) within the context of a geologic repository program is a post-closure safety assessment; a system analysis of hazards associated with the facility and the ability of the site and the design of the facility to provide for the safety functions. For the last few decades, PA methodology bas been developed and applied to different waste disposal programs around the world. PA has been used in the safety analyses for waste disposal repositories for low-level waste, intermediate level waste, and high-level waste including spent nuclear fuels. This paper provides an overview of the performance assessment methodology and gives examples of its applications for the Yucca Mountain Project. (authors)

  16. Radioactive Waste Management Complex performance assessment: Draft

    Energy Technology Data Exchange (ETDEWEB)

    Case, M.J.; Maheras, S.J.; McKenzie-Carter, M.A.; Sussman, M.E.; Voilleque, P.

    1990-06-01

    A radiological performance assessment of the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory was conducted to demonstrate compliance with appropriate radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the general public. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the general public via air, ground water, and food chain pathways. Projections of doses were made for both offsite receptors and individuals intruding onto the site after closure. In addition, uncertainty analyses were performed. Results of calculations made using nominal data indicate that the radiological doses will be below appropriate radiological criteria throughout operations and after closure of the facility. Recommendations were made for future performance assessment calculations.

  17. Radioactive Waste Management Complex performance assessment: Draft

    International Nuclear Information System (INIS)

    Case, M.J.; Maheras, S.J.; McKenzie-Carter, M.A.; Sussman, M.E.; Voilleque, P.

    1990-06-01

    A radiological performance assessment of the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory was conducted to demonstrate compliance with appropriate radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the general public. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the general public via air, ground water, and food chain pathways. Projections of doses were made for both offsite receptors and individuals intruding onto the site after closure. In addition, uncertainty analyses were performed. Results of calculations made using nominal data indicate that the radiological doses will be below appropriate radiological criteria throughout operations and after closure of the facility. Recommendations were made for future performance assessment calculations

  18. The effects of performance-based assessment criteria on student performance and self-assessment skills

    NARCIS (Netherlands)

    Fastré, Greet; Van der Klink, Marcel; Van Merriënboer, Jeroen

    2010-01-01

    Fastré, G. M. J., Van der Klink, M. R., & Van Merriënboer, J. J. G. (2010). The effects of performance-based assessment criteria on student performance and self-assessment skills. Advances in Health Science Education, 15(4), 517-532.

  19. Putting HLW performance assessment results in perspective

    International Nuclear Information System (INIS)

    Neall, F.; Smith, P.; Sumerling, T.; Umeki, H.

    1995-01-01

    According to performance assessment results for the different disposal concepts investigated, the maximum radiation doses to the population lie well below the limit set in the official Swiss Protection Objective and below the level of present-day natural background radiation. A comparison of different performance assessments has shown that the following key factors determine radionuclide release from a repository: radionuclide inventory, canister material and failure mode, nuclide solubility limits, the permeability of the buffer material, retardation during transport through the near-field, the presence of an excavation disturbed zone in the rock, the distance to the nearest major water-bearing fracture zone, the conceptual model for transport in fractured rock and near-surface dilution and dose factors. (author) 2 figs., 2 tabs

  20. Assessing the performance of dynamical trajectory estimates

    Science.gov (United States)

    Bröcker, Jochen

    2014-06-01

    Estimating trajectories and parameters of dynamical systems from observations is a problem frequently encountered in various branches of science; geophysicists for example refer to this problem as data assimilation. Unlike as in estimation problems with exchangeable observations, in data assimilation the observations cannot easily be divided into separate sets for estimation and validation; this creates serious problems, since simply using the same observations for estimation and validation might result in overly optimistic performance assessments. To circumvent this problem, a result is presented which allows us to estimate this optimism, thus allowing for a more realistic performance assessment in data assimilation. The presented approach becomes particularly simple for data assimilation methods employing a linear error feedback (such as synchronization schemes, nudging, incremental 3DVAR and 4DVar, and various Kalman filter approaches). Numerical examples considering a high gain observer confirm the theory.

  1. Partai Islam Se-Malaysia (PAS dan Partai Keadilan Sejahtera (PKS sebagai Partai Islam Pendukung Demokrasi PKS Pada Pemilu

    Directory of Open Access Journals (Sweden)

    Ahmad Ali Nurdin

    2015-11-01

    Full Text Available The article compares the achievement of Partai Islam se-Malaysia (PAS and Partai Keadilan Sejahtera (PKS in the latest general election held in 2013 in Malaysia and in 2014 in Indonesia. The writer finds that the political performance of PAS and PKS has indicated differently contrast results. While political electability of PAS in the 2013 Malaysia’s general election has disappointed this party, PKS has successfully proved that surveys held by a number of survey institutes—predicting that the party would cease within the 2014 Indonesia’s national election—were totally false. Many political figures of PAS have failed to gain positions in the legislative assembly. Meanwhile, in viewing PKS’s political performance during the 2014 national election, one may assume that this party was luckily survive. This is because, a number of surveys conducted before the election had predicted that PKS could be considered lucky when it was able to gain five percent of vote, as its former president has been suspected of being corrupt for his involvement in cows import. However, the fact shows that PKS has not only magnificently survived but it was even able to gain almost seven percent of voters’ vote. Unfortunately, PKS was unsuccessful to achieve its political target to be the biggest three of national vote.

  2. ASSESSING STUDENT PERFORMANCE ON INTERPRETING THROUGH PEER-ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Titik Ismailia

    2017-12-01

    Full Text Available As a part of translation interpreting is translating spoken discourse orally. It needs some requirements like ability to speak clearly, clarity, fluency, eye contact, and self-confidence. It also needs linguistic proficiency, analytical skill, listening and recall, interpersonal skills, ethical behaviour, speaking skills, cultural knowledge, and subject knowledge. Evaluating students performance on interpreting can be done through peer assessment. Peer- assessment is one of alternative assessment to grade the peers in group or individuals by commenting on and judging other students work. To do this process there is a join work between listening and speaking, and two students. The first student as a speaker and the second student as an interpreter. Both of them should do the same quality on speak clearly as a speaker and as an interpreter should able to listen and translating the spoken discourse orally. Evaluation can use analytical grade that allows teacher to set clear criteria for correction like fluency, grammar, terminology, general content, and mechanics. Students and teacher can give comment on every criteria based on their own competency. During the process on making criteria, students and teacher can discuss and give reasonable suggestion to make the assessment suitable to the students competency. At the end, a rubric of assessment with the score from 0 to 100 and criteria and also the comment included in the paper of assessment.

  3. Tailored model abstraction in performance assessments

    International Nuclear Information System (INIS)

    Kessler, J.H.

    1995-01-01

    Total System Performance Assessments (TSPAs) are likely to be one of the most significant parts of making safety cases for the continued development and licensing of geologic repositories for the disposal of spent fuel and HLW. Thus, it is critical that the TSPA model capture the 'essence' of the physical processes relevant to demonstrating the appropriate regulation is met. But how much detail about the physical processes must be modeled and understood before there is enough confidence that the appropriate essence has been captured? In this summary the level of model abstraction that is required is discussed. Approaches for subsystem and total system performance analyses are outlined, and the role of best estimate models is examined. It is concluded that a conservative approach for repository performance, based on limited amount of field and laboratory data, can provide sufficient confidence for a regulatory decision

  4. ASSESSING UNIVERSITY RESEARCH PERFORMANCE WITH MULTIPLE CONSTITUENCIES

    Directory of Open Access Journals (Sweden)

    Kuang-Liang Liu

    2012-12-01

    Full Text Available The research performance of the university is critical to the national competitiveness. Previous research has established that research performance is based on scholarly publishing. Several studies suggested that journal ranking is the important research quality indicator. However, unilateral measurement for the research performance will seriously corrode the development of university research work. Assessing university research performance with multiple constituencies is a better to enhance the university research. Although substantial studies have been performed on the critical factors that affect knowledge exploration in the university, those in knowledge exploitation are still lacking. With the multiple constituencies, a fully understanding of research performance can be gained. In the research model, knowledge exploration represents the academic research and knowledge exploitation represents the university–industry collaboration. Data collected from 124 university data in online database. The study shows that knowledge exploration and exploitation both are significant positive predictors of university competitiveness. University resources play important roles to affect both knowledge exploration and exploitation in the university. The study also shows that higher knowledge exploration will enhance knowledge exploitation. Implications for theory and practice and suggestions for future research are discussed.

  5. Statistical analysis in MSW collection performance assessment.

    Science.gov (United States)

    Teixeira, Carlos Afonso; Avelino, Catarina; Ferreira, Fátima; Bentes, Isabel

    2014-09-01

    The increase of Municipal Solid Waste (MSW) generated over the last years forces waste managers pursuing more effective collection schemes, technically viable, environmentally effective and economically sustainable. The assessment of MSW services using performance indicators plays a crucial role for improving service quality. In this work, we focus on the relevance of regular system monitoring as a service assessment tool. In particular, we select and test a core-set of MSW collection performance indicators (effective collection distance, effective collection time and effective fuel consumption) that highlights collection system strengths and weaknesses and supports pro-active management decision-making and strategic planning. A statistical analysis was conducted with data collected in mixed collection system of Oporto Municipality, Portugal, during one year, a week per month. This analysis provides collection circuits' operational assessment and supports effective short-term municipality collection strategies at the level of, e.g., collection frequency and timetables, and type of containers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Tax Performance Assessment in Scandinavian Countries

    Directory of Open Access Journals (Sweden)

    Bunescu Liliana

    2015-04-01

    Full Text Available The aim of this paper is to evaluate fiscal policy performance level in Nordic countries of Europe by quantifying the gap between their performance and an optimum benchmark value. In this study it was selected Denmark, Finland, Sweden and Norway. These countries occupy the first places in the ranking of countries with the highest rate of tax burden in Europe. The first part of paper contains general aspects of fiscal performance in international research and an overview of the Nordic tax systems model. The second part of paper focuses on evaluation of tax policy performance in these countries by using OptimTax scoring analysis. The research is based on a multivariate analysis instrument that uses quantitative data on various aspects of tax policy. OptimTax achieves a score for assessing the degree of optimization of fiscal policy. The results reveal high levels of tax performance in Scandinavian countries and a trend that seems to be more constant than ascending, except Norway.

  7. A global assessment of the social and conservation outcomes of protected areas.

    Science.gov (United States)

    Oldekop, J A; Holmes, G; Harris, W E; Evans, K L

    2016-02-01

    Protected areas (PAs) are a key strategy for protecting biological resources, but they vary considerably in their effectiveness and are frequently reported as having negative impacts on local people. This has contributed to a divisive and unresolved debate concerning the compatibility of environmental and socioeconomic development goals. Elucidating the relationship between positive and negative social impacts and conservation outcomes of PAs is key for the development of more effective and socially just conservation. We conducted a global meta-analysis on 165 PAs using data from 171 published studies. We assessed how PAs affect the well-being of local people, the factors associated with these impacts, and crucially the relationship between PAs' conservation and socioeconomic outcomes. Protected areas associated with positive socioeconomic outcomes were more likely to report positive conservation outcomes. Positive conservation and socioeconomic outcomes were more likely to occur when PAs adopted comanagement regimes, empowered local people, reduced economic inequalities, and maintained cultural and livelihood benefits. Whereas the strictest regimes of PA management attempted to exclude anthropogenic influences to achieve biological conservation objectives, PAs that explicitly integrated local people as stakeholders tended to be more effective at achieving joint biological conservation and socioeconomic development outcomes. Strict protection may be needed in some circumstances, yet our results demonstrate that conservation and development objectives can be synergistic and highlight management strategies that increase the probability of maximizing both conservation performance and development outcomes of PAs. © 2015 The Authors. Conservation Biology published by Wiley Periodicals, Inc. on behalf of Society for Conservation Biology.

  8. Performance assessment modeling of pyrometallurgical process wasteforms

    International Nuclear Information System (INIS)

    Nutt, W.M.; Hill, R.N.; Bullen, D.B.

    1995-01-01

    Performance assessment analyses have been completed to estimate the behavior of high-level nuclear wasteforms generated from the pyrometallurgical processing of liquid metal reactor (LMR) and light water reactor (LWR) spent nuclear fuel. Waste emplaced in the proposed repository at Yucca Mountain is investigated as the basis for the study. The resulting cumulative actinide and fission product releases to the accessible environment within a 100,000 year period from the various pyrometallurgical process wasteforms are compared to those of directly disposed LWR spent fuel using the same total repository system model. The impact of differing radionuclide transport models on the overall release characteristics is investigated

  9. Building Confidence in LLW Performance Assessments - 13386

    Energy Technology Data Exchange (ETDEWEB)

    Rustick, Joseph H.; Kosson, David S.; Krahn, Steven L.; Clarke, James H. [Vanderbilt University, Department of Civil and Environmental Engineering and Consortium for Risk Evaluation with Stakeholder Participation, Nashville, Tennessee, 37235 (United States)

    2013-07-01

    The performance assessment process and incorporated input assumptions for four active and one planned DOE disposal sites were analyzed using a systems approach. The sites selected were the Savannah River E-Area Slit and Engineered Trenches, Hanford Integrated Disposal Facility, Idaho Radioactive Waste Management Complex, Oak Ridge Environmental Management Waste Management Facility, and Nevada National Security Site Area 5. Each disposal facility evaluation incorporated three overall system components (1) site characteristics (climate, geology, geochemistry, etc.), (2) waste properties (waste form and package), and (3) engineered barrier designs (cover system, liner system). Site conceptual models were also analyzed to identity the main risk drivers and risk insights controlling performance for each disposal facility. (authors)

  10. Building Confidence in LLW Performance Assessments - 13386

    International Nuclear Information System (INIS)

    Rustick, Joseph H.; Kosson, David S.; Krahn, Steven L.; Clarke, James H.

    2013-01-01

    The performance assessment process and incorporated input assumptions for four active and one planned DOE disposal sites were analyzed using a systems approach. The sites selected were the Savannah River E-Area Slit and Engineered Trenches, Hanford Integrated Disposal Facility, Idaho Radioactive Waste Management Complex, Oak Ridge Environmental Management Waste Management Facility, and Nevada National Security Site Area 5. Each disposal facility evaluation incorporated three overall system components (1) site characteristics (climate, geology, geochemistry, etc.), (2) waste properties (waste form and package), and (3) engineered barrier designs (cover system, liner system). Site conceptual models were also analyzed to identity the main risk drivers and risk insights controlling performance for each disposal facility. (authors)

  11. 47 CFR Appendix B to Part 64 - Priority Access Service (PAS) for National Security and Emergency Preparedness (NSEP)

    Science.gov (United States)

    2010-10-01

    ... PAS, enforce PAS rules and regulations, and act as final authority for approval, revision, or.... f. The Telecommunications Service Priority Oversight Committee will identify and review any systemic...

  12. The presence of glutamate residues on the PAS sequence of the stimuli-sensitive nano-ferritin improves in vivo biodistribution and mitoxantrone encapsulation homogeneity.

    Science.gov (United States)

    Falvo, Elisabetta; Malagrinò, Francesca; Arcovito, Alessandro; Fazi, Francesco; Colotti, Gianni; Tremante, Elisa; Di Micco, Patrizio; Braca, Aldo; Opri, Roberta; Giuffrè, Alessandro; Fracasso, Giulio; Ceci, Pierpaolo

    2018-04-10

    A genetically engineered human ferritin heavy chain (HFt)-based construct has been recently shown by our group to efficiently entrap and deliver doxorubicin to cancer cells. This construct, named HFt-MP-PAS, contained a tumor-selective sequence (MP) responsive to proteolytic cleavage by tumor proteases (MMPs), located between each HFt subunit and an outer shielding polypeptide sequence rich in proline (P), serine (S) and alanine (A) residues (PAS). HFt-MP-PAS displayed excellent therapeutic efficacy in xenogenic pancreatic and head and neck cancer models in vivo, leading to a significant increase in overall animal survivals. Here we report a new construct obtained by the genetic insertion of two glutamate residues in the PAS sequence of HFt-MP-PAS. Such new construct, named HFt-MP-PASE, is characterized by improved performances as drug biodistribution in a xenogenic pancreatic cancer model in vivo. Moreover, HFt-MP-PASE efficiently encapsulates the anti-cancer drug mitoxantrone (MIT), and the resulting MIT-loaded nanoparticles proved to be more soluble and monodispersed than the HFt-MP-PAS counterparts. Importantly, in vitro MIT-loaded HFt-MP-PASE kills several cancer cell lines of different origin (colon, breast, sarcoma and pancreas) at least as efficiently as the free drug. Finally, our MIT loaded protein nanocages allowed in vivo an impressive incrementing of the drug accumulation in the tumor with respect to the free drug. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Software Quality Assurance Plan for GoldSim Models Supporting the Area 3 and Area 5 Radioactive Waste Management Site Performance Assessment Program

    International Nuclear Information System (INIS)

    Gregory J. Shott, Vefa Yucel

    2007-01-01

    This Software Quality Assurance Plan (SQAP) applies to the development and maintenance of GoldSim models supporting the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) performance assessments (PAs) and composite analyses (CAs). Two PA models have been approved by the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) as of November 2006 for the PA maintenance work undertaken by National Security Technologies, LLC (NSTec). NNSA/NSO asked NSTec to assume the custodianship of the models for future development and maintenance. The models were initially developed by Neptune and Company (N and C)

  14. Software Quality Assurance Plan for GoldSim Models Supporting the Area 3 and Area 5 Radioactive Waste Management Sites Performance Assessment Program

    Energy Technology Data Exchange (ETDEWEB)

    Gregory J. Shott, Vefa Yucel

    2007-01-03

    This Software Quality Assurance Plan (SQAP) applies to the development and maintenance of GoldSim models supporting the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) performance assessments (PAs) and composite analyses (CAs). Two PA models have been approved by the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) as of November 2006 for the PA maintenance work undertaken by National Security Technologies, LLC (NSTec). NNSA/NSO asked NSTec to assume the custodianship of the models for future development and maintenance. The models were initially developed by Neptune and Company (N&C).

  15. Performance assessment of nuclear waste isolation systems

    International Nuclear Information System (INIS)

    Lee, W.L.

    1984-01-01

    A number of concepts have been proposed for the isolation of highly radioactive wastes, and it will be necessary to demonstrate the safety of such systems. In many countries including the U.S., the waste isolation system of choice is deep mined geologic repositories. Because of the complex nature of the multiple isolation barriers afforded by mined geologic disposal systems, and the long isolation periods involved, this demonstration can only be indirect. In recent years this indirect demonstration, mostly through mathematical modeling, is called performance assessment. Performance Assessment can be defined to mean the development, testing, and application of a series of mathematical models and computer codes which traces the movement of radionuclides from a waste isolation system to the biosphere and any resultant dose to man. In modeling such a repository system, it is often convenient to divide it into a number of subsystems, there may be several different processes that need to be modeled, individually and interactively. For instance, this waste package will probably consist of a waste form such as borosilicate glass containing the radioisotopes, a canister, an overpack material such as steel or copper, and a buffer material such as bentonite. The processes to be modeled at the waste package scale include radioisotope inventory and decay, thermal radiation, radiolysis effects, corrosion, leading and fluid flow. In tracing radionuclide transport through rock, the processes of importance are probably groundwater flow, and sorption and retardation of radionuclide movement

  16. Modelling saline intrusion for repository performance assessment

    International Nuclear Information System (INIS)

    Jackson, C.P.

    1989-04-01

    UK Nirex Ltd are currently considering the possibility of disposal of radioactive waste by burial in deep underground repositories. The natural pathway for radionuclides from such a repository to return to Man's immediate environment (the biosphere) is via groundwater. Thus analyses of the groundwater flow in the neighbourhood of a possible repository, and consequent radionuclide transport form an important part of a performance assessment for a repository. Some of the areas in the UK that might be considered as possible locations for a repository are near the coast. If a repository is located in a coastal region seawater may intrude into the groundwater flow system. As seawater is denser than fresh water buoyancy forces acting on the intruding saline water may have significant effects on the groundwater flow system, and consequently on the time for radionuclides to return to the biosphere. Further, the chemistry of the repository near-field may be strongly influenced by the salinity of the groundwater. It is therefore important for Nirex to have a capability for reliably modelling saline intrusion to an appropriate degree of accuracy in order to make performance assessments for a repository in a coastal region. This report describes work undertaken in the Nirex Research programme to provide such a capability. (author)

  17. Consideration of environmental change in performance assessments

    International Nuclear Information System (INIS)

    Pinedo, P.; Thorne, M.; Egan, M.; Calvez, M.; Kautsky, U.

    2005-01-01

    Depending on the particular circumstances in which a post-closure performance assessment of a radioactive waste repository is made, it may be appropriate to follow simple or more complex approaches in characterising the biosphere. Several different Example Reference Biospheres were explored in BIOMASS Theme 1 to address a range of issues that arise. Here, consideration is given to Example Reference Biospheres relevant to representing the implications of changes that may occur within the biosphere system during the period over which releases of radionuclides from a disposal facility might take place. Mechanisms of change considered include those extrinsic and intrinsic to the system of interest. An overall methodology for incorporating environmental change into assessments is proposed. This includes screening of primary mechanisms of change; identification of possible time sequences of change; development of a coherent description of the regional landscape response for each time sequence; integration of source term and geosphere-biosphere interface information; identification and description of one or more time series of assessment biospheres; and evaluation of the advantages and disadvantages of simulating the effects of sequences of biosphere systems and the transitions between them, or of defining a set of biosphere systems to be represented individually in a non-sequential analysis. The usefulness of the methodology is explored in two site-specific examples and one generic example

  18. A history of PAs in the US Public Health Service.

    Science.gov (United States)

    McKinnon, Mark F; Elizondo, Epifanio; Bonfiglio, Susan M; Hunter-Buskey, Robin N; Placide, Frances P; Bunnell, Rebecca A

    2016-12-01

    Since 1798, the men and women of the Commissioned Corps of the US Public Health Service (USPHS), one of the seven US uniformed services, have served on the front lines of public health. Two hundred years after the start of the USPHS, the first physician assistant (PA) entered the service to carry on the tradition of protecting, promoting, and advancing the health and safety of the nation. These dedicated clinicians are involved in healthcare delivery to underserved and vulnerable populations, disease control and prevention, biomedical research, food and drug regulation, and national and international response efforts for natural and man-made disasters. This article describes how PAs in the Commissioned Corps of the USPHS have impacted the health and safety of not only the United States but also the international community.

  19. Die dramatiese discours in Pas de deux van Hugo Claus

    Directory of Open Access Journals (Sweden)

    R. Vaughan

    1990-05-01

    Full Text Available Drama is action, verbal drama is speech action, and the dramatic text is subject to a similar set of rules as that governing the extra-literary communication situation. Dramatic irony, the very essence of drama itself, is generated by a dual, mutually interactive process of communication, whereby the audience is “written into” the text in a way distinguishing it from other literary genres, and by a systematic flouting of the rules governing communication. Pas de deux demonstrates the peculiar duality of dramatic discourse by its complex exploitation of the breakdown/non-breakdown of Grice’s Co-operative Principle-. communication/non-communication becomes reversible and, therefore, mutually constitutive concepts “releasing meaning” and conveying the “ideology” of this play.

  20. Scientific performance assessments through a gender lens

    DEFF Research Database (Denmark)

    Nielsen, Mathias Wullum

    2018-01-01

    The focus on excellence and quality assurance in the academy has spawned a signifi cant increase in the use of bibliometric measures in performance assessments of individual researchers. This article investigates the organizational consequences of this development through a gender lens. Based...... scholars, evaluators using bibliometrics risk disadvantaging candidates diverging from the norm with implications for gender stratifi cation. Despite these potential biases, bibliometric measures come to function as technologies supporting a managerial narrative of the gender-blind organization....... They adhere to the prevailing ethos of the academic meritocracy by standardizing the criteria for organizational advancement and ensuring transparency and accountability in the selection process. While bibliometric tools in this sense may lead to the recruitment of scientists with a strong CV and track record...

  1. Performing Probabilistic Risk Assessment Through RAVEN

    Energy Technology Data Exchange (ETDEWEB)

    A. Alfonsi; C. Rabiti; D. Mandelli; J. Cogliati; R. Kinoshita

    2013-06-01

    The Reactor Analysis and Virtual control ENviroment (RAVEN) code is a software tool that acts as the control logic driver and post-processing engine for the newly developed Thermal-Hydraulic code RELAP-7. RAVEN is now a multi-purpose Probabilistic Risk Assessment (PRA) software framework that allows dispatching different functionalities: Derive and actuate the control logic required to simulate the plant control system and operator actions (guided procedures), allowing on-line monitoring/controlling in the Phase Space Perform both Monte-Carlo sampling of random distributed events and Dynamic Event Tree based analysis Facilitate the input/output handling through a Graphical User Interface (GUI) and a post-processing data mining module

  2. Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992

    International Nuclear Information System (INIS)

    1992-12-01

    Before disposing of transuranic radioactive waste in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments (PAs) of the WIPP for the DOE to provide interim guidance while preparing for a final compliance evaluation. This volume, Volume 2, contains the technical basis for the 1992 PA. Specifically, it describes the conceptual basis for consequence modeling and the PA methodology, including the selection of scenarios for analysis, the determination of scenario probabilities, and the estimation of scenario consequences using a Monte Carlo technique and a linked system of computational models. Additional information about the 1992 PA is provided in other volumes. Volume I contains an overview of WIPP PA and results of a preliminary comparison with the long-term requirements of the EPA's Environmental Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). Volume 3 contains the reference data base and values for input parameters used in consequence and probability modeling. Volume 4 contains uncertainty and sensitivity analyses related to the preliminary comparison with 40 CFR 191B. Volume 5 contains uncertainty and sensitivity analyses of gas and brine migration for undisturbed performance. Finally, guidance derived from the entire 1992 PA is presented in Volume 6

  3. Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992

    International Nuclear Information System (INIS)

    1993-08-01

    Before disposing of transuranic radioactive waste in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments (PAs) of the WIPP for the DOE to provide interim guidance while preparing for a final compliance evaluation. This volume of the 1992 PA contains results of uncertainty and sensitivity analyses with respect to the EPA's Environmental Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). Additional information about the 1992 PA is provided in other volumes. Results of the 1992 uncertainty and sensitivity analyses indicate that, conditional on the modeling assumptions, the choice of parameters selected for sampling, and the assigned parameter-value distributions, the most important parameters for which uncertainty has the potential to affect compliance with 40 CFR 191B are: drilling intensity, intrusion borehole permeability, halite and anhydrite permeabilities, radionuclide solubilities and distribution coefficients, fracture spacing in the Culebra Dolomite Member of the Rustler Formation, porosity of the Culebra, and spatial variability of Culebra transmissivity. Performance with respect to 40 CFR 191B is insensitive to uncertainty in other parameters; however, additional data are needed to confirm that reality lies within the assigned distributions

  4. Multi-PAS domain-mediated protein oligomerization of PpsR from Rhodobacter sphaeroides

    International Nuclear Information System (INIS)

    Heintz, Udo; Meinhart, Anton; Winkler, Andreas

    2014-01-01

    Crystal structures of two truncated variants of the transcription factor PpsR from R. sphaeroides are presented that enabled the phasing of a triple PAS domain construct. Together, these structures reveal the importance of α-helical PAS extensions for multi-PAS domain-mediated protein oligomerization and function. Per–ARNT–Sim (PAS) domains are essential modules of many multi-domain signalling proteins that mediate protein interaction and/or sense environmental stimuli. Frequently, multiple PAS domains are present within single polypeptide chains, where their interplay is required for protein function. Although many isolated PAS domain structures have been reported over the last decades, only a few structures of multi-PAS proteins are known. Therefore, the molecular mechanism of multi-PAS domain-mediated protein oligomerization and function is poorly understood. The transcription factor PpsR from Rhodobacter sphaeroides is such a multi-PAS domain protein that, in addition to its three PAS domains, contains a glutamine-rich linker and a C-terminal helix–turn–helix DNA-binding motif. Here, crystal structures of two N-terminally and C-terminally truncated PpsR variants that comprise a single (PpsR Q-PAS1 ) and two (PpsR N-Q-PAS1 ) PAS domains, respectively, are presented and the multi-step strategy required for the phasing of a triple PAS domain construct (PpsR ΔHTH ) is illustrated. While parts of the biologically relevant dimerization interface can already be observed in the two shorter constructs, the PpsR ΔHTH structure reveals how three PAS domains enable the formation of multiple oligomeric states (dimer, tetramer and octamer), highlighting that not only the PAS cores but also their α-helical extensions are essential for protein oligomerization. The results demonstrate that the long helical glutamine-rich linker of PpsR results from a direct fusion of the N-cap of the PAS1 domain with the C-terminal extension of the N-domain that plays an important

  5. Probabilistic Radiological Performance Assessment Modeling and Uncertainty

    Science.gov (United States)

    Tauxe, J.

    2004-12-01

    A generic probabilistic radiological Performance Assessment (PA) model is presented. The model, built using the GoldSim systems simulation software platform, concerns contaminant transport and dose estimation in support of decision making with uncertainty. Both the U.S. Nuclear Regulatory Commission (NRC) and the U.S. Department of Energy (DOE) require assessments of potential future risk to human receptors of disposal of LLW. Commercially operated LLW disposal facilities are licensed by the NRC (or agreement states), and the DOE operates such facilities for disposal of DOE-generated LLW. The type of PA model presented is probabilistic in nature, and hence reflects the current state of knowledge about the site by using probability distributions to capture what is expected (central tendency or average) and the uncertainty (e.g., standard deviation) associated with input parameters, and propagating through the model to arrive at output distributions that reflect expected performance and the overall uncertainty in the system. Estimates of contaminant release rates, concentrations in environmental media, and resulting doses to human receptors well into the future are made by running the model in Monte Carlo fashion, with each realization representing a possible combination of input parameter values. Statistical summaries of the results can be compared to regulatory performance objectives, and decision makers are better informed of the inherently uncertain aspects of the model which supports their decision-making. While this information may make some regulators uncomfortable, they must realize that uncertainties which were hidden in a deterministic analysis are revealed in a probabilistic analysis, and the chance of making a correct decision is now known rather than hoped for. The model includes many typical features and processes that would be part of a PA, but is entirely fictitious. This does not represent any particular site and is meant to be a generic example. A

  6. E-Area Performance Assessment Interim Measures Assessment FY2005

    Energy Technology Data Exchange (ETDEWEB)

    Stallings, M

    2006-01-31

    After major changes to the limits for various disposal units of the E-Area Low Level Waste Facility (ELLWF) last year, no major changes have been made during FY2005. A Special Analysis was completed which removes the air pathway {sup 14}C limit from the Intermediate Level Vault (ILV). This analysis will allow the disposal of reactor moderator deionizers which previously had no pathway to disposal. Several studies have also been completed providing groundwater transport input for future special analyses. During the past year, since Slit Trenches No.1 and No.2 were nearing volumetric capacity, they were operationally closed under a preliminary closure analysis. This analysis was performed using as-disposed conditions and data and showed that concrete rubble from the demolition of 232-F was acceptable for disposal in the STs even though the latest special analysis for the STs had reduced the tritium limits so that the inventory in the rubble exceeded limits. A number of special studies are planned during the next years; perhaps the largest of these will be revision of the Performance Assessment (PA) for the ELLWF. The revision will be accomplished by incorporating special analyses performed since the last PA revision as well as revising analyses to include new data. Projected impacts on disposal limits of more recent studies have been estimated. No interim measures will be applied during this year. However, it is being recommended that tritium disposals to the Components-in-Grout (CIG) Trenches be suspended until a limited Special Analysis (SA) currently in progress is completed. This SA will give recommendations for optimum placement of tritiated D-Area tower waste. Further recommendations for tritiated waste placement in the CIG Trenches will be given in the upcoming PA revision.

  7. Maintenance Plan for the Performance Assessments and Composite Analyses for the Area 3 and Area 5 Radioactive Waste Management Sites at the NTS

    Energy Technology Data Exchange (ETDEWEB)

    Vefa Yucel

    2007-01-03

    U.S. Department of Energy (DOE) Manual M 435.1-1 requires that performance assessments (PAs) and composite analyses (CAs) for low-level waste (LLW) disposal facilities be maintained by the field offices. This plan describes the activities performed to maintain the PA and the CA for the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS). This plan supersedes the Maintenance Plan for the Performance Assessments and Composite Analyses for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site (DOE/NV/11718--491-REV 1, dated September 2002). The plan is based on U.S. Department of Energy (DOE) Order 435.1 (DOE, 1999a), DOE Manual M 435.1-1 (DOE, 1999b), the DOE M 435.1-1 Implementation Guide DOE G 435.1-1 (DOE, 1999c), and the Maintenance Guide for PAs and CAs (DOE, 1999d). The plan includes a current update on PA/CA documentation, a revised schedule, and a section on Quality Assurance.

  8. Maintenance Plan for the Performance Assessments and Composite Analyses of the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site

    International Nuclear Information System (INIS)

    Vefa Yucel

    2007-01-01

    U.S. Department of Energy (DOE) Manual M 435.1-1 requires that performance assessments (PAs) and composite analyses (CAs) for low-level waste (LLW) disposal facilities be maintained by the field offices. This plan describes the activities performed to maintain the PA and the CA for the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS). This plan supersedes the Maintenance Plan for the Performance Assessments and Composite Analyses for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site (DOE/NV/11718--491-REV 1, dated September 2002). The plan is based on U.S. Department of Energy (DOE) Order 435.1 (DOE, 1999a), DOE Manual M 435.1-1 (DOE, 1999b), the DOE M 435.1-1 Implementation Guide DOE G 435.1-1 (DOE, 1999c), and the Maintenance Guide for PAs and CAs (DOE, 1999d). The plan includes a current update on PA/CA documentation, a revised schedule, and a section on Quality Assurance

  9. Comparative Assessment of Health Workers Performance and The ...

    African Journals Online (AJOL)

    Comparative Assessment of Health Workers Performance and The Performance ... had very high significant effect on performance of health workers which was independent of ... Keywords: Health Worker Performance Factors Hospitals Nigeria ...

  10. Assessing Ecosystem Model Performance in Semiarid Systems

    Science.gov (United States)

    Thomas, A.; Dietze, M.; Scott, R. L.; Biederman, J. A.

    2017-12-01

    In ecosystem process modelling, comparing outputs to benchmark datasets observed in the field is an important way to validate models, allowing the modelling community to track model performance over time and compare models at specific sites. Multi-model comparison projects as well as models themselves have largely been focused on temperate forests and similar biomes. Semiarid regions, on the other hand, are underrepresented in land surface and ecosystem modelling efforts, and yet will be disproportionately impacted by disturbances such as climate change due to their sensitivity to changes in the water balance. Benchmarking models at semiarid sites is an important step in assessing and improving models' suitability for predicting the impact of disturbance on semiarid ecosystems. In this study, several ecosystem models were compared at a semiarid grassland in southwestern Arizona using PEcAn, or the Predictive Ecosystem Analyzer, an open-source eco-informatics toolbox ideal for creating the repeatable model workflows necessary for benchmarking. Models included SIPNET, DALEC, JULES, ED2, GDAY, LPJ-GUESS, MAESPA, CLM, CABLE, and FATES. Comparison between model output and benchmarks such as net ecosystem exchange (NEE) tended to produce high root mean square error and low correlation coefficients, reflecting poor simulation of seasonality and the tendency for models to create much higher carbon sources than observed. These results indicate that ecosystem models do not currently adequately represent semiarid ecosystem processes.

  11. Thermodynamics, data estimation and performance assessment

    International Nuclear Information System (INIS)

    Grenthe, I.

    2002-01-01

    Performance assessment provides a narrative of a system and its development. One may use a literary metaphor; the procedure is like writing a novel where the 'chapters' are the various sub-systems and where both the 'plot' and the 'grammar' are based on scientific and other information, some hard facts and other more or less reliable guesses. I will begin with some general remarks on models, which may provide a useful starting point for what follows. - Models never provide complete descriptions of real systems; they are used to highlight certain aspects of them and to answer 'what-if' questions; - Modelling is an iterative process that provides guidance as to what are important phenomena and what is less relevant for the description of the system and its function; - It is necessary to distinguish between model uncertainties and parameter uncertainties; - It is often better to estimate a quantity for which no data are available than to exclude the particular process where it is needed. Thermodynamics provide not only numerical values for different chemical processes, but more important a theory framework that can be used for the estimation of data. I will not discuss activity coefficient corrections of thermodynamic data, an important area that has already been addressed by Professor Fanghaenel. In the following overview I will be using examples of estimations of different kinds to illustrate what can be accomplished using thermodynamics in combination with chemical theories. (author)

  12. Progression of performance assessment modeling for the Yucca Mountain disposal system for spent nuclear fuel and high-level radioactive waste

    International Nuclear Information System (INIS)

    Rechard, Rob P.; Wilson, Michael L.; Sevougian, S. David

    2014-01-01

    This paper summarizes the evolution of consequence modeling for a repository for spent nuclear fuel and high-level radioactive waste at Yucca Mountain in southern Nevada. The discussion includes four early performance assessments (PAs) conducted between 1982 and 1995 to support selection and to evaluate feasibility and three major PAs conducted between 1998 and 2008 to evaluate viability, recommend the site, and assess compliance. Modeling efforts in 1982 estimated dose to individuals 18 km from the site caused by volcanic eruption through the repository. Modeling in 1984 estimated releases via the groundwater pathway because of container corrosion. In combination, this early analysis supported the first environmental assessment. Analysts in 1991 evaluated cumulative release, as specified in the 1985 US radiation protection standards, via the groundwater pathway over 10 4 yr at a 5-km boundary by modeling waste degradation and flow/transport in the saturated and unsaturated zones. By 1992, however, the US Congress mandated a change to a dose measure. Thus, the 1993 and 1995 performance assessments improved modeling of waste container degradation to provide better estimates of radionuclide release rates out to 10 6 yr. The 1998 viability assessment was a major step in modeling complexity. Dose at a 20-km boundary from the repository was evaluated through 10 6 yr for undisturbed conditions using more elaborate modeling of flow and the addition of modules for modeling infiltration, drift seepage, the chemical environment, and biosphere transport. The 2000 assessment for the site recommendation refined the analysis. Seepage modeling was greatly improved and waste form degradation modeling included more chemical dependence. The 2008 compliance assessment for the license application incorporated the influence of the seismicity on waste package performance to evaluate dose at an ∼18-km boundary. - Highlights: • Evolution of the consequence models to simulate physical

  13. An introduction to the mechanics of performance assessment using examples of calculations done for the Waste Isolation Pilot Plant between 1990 and 1992

    International Nuclear Information System (INIS)

    Rechard, R.P.

    1995-10-01

    This document provides an overview of the process used to assess the performance of the Waste Isolation Pilot Plant (WIPP), a proposed repository for transuranic wastes that is located in southeastern New Mexico. The quantitative metrics used in the performance-assessment (PA) process are those put forward in the Environmental Protection Agency's Environmental Standards for the Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive flasks (40 CFR 191). Much has been written about the individual building blocks that comprise the foundation of PA theory and practice, and that WIPP literature is well cited herein. However, the present approach is to provide an accurate, well documented overview of the process, from the perspective of the mechanical steps used to perform the actual PA calculations. Specifically, the preliminary stochastic simulations that comprise the WIPP PAs of 1990, 1991. and 1992 are summarized

  14. An introduction to the mechanics of performance assessment using examples of calculations done for the Waste Isolation Pilot Plant between 1990 and 1992

    Energy Technology Data Exchange (ETDEWEB)

    Rechard, R.P.

    1995-10-01

    This document provides an overview of the process used to assess the performance of the Waste Isolation Pilot Plant (WIPP), a proposed repository for transuranic wastes that is located in southeastern New Mexico. The quantitative metrics used in the performance-assessment (PA) process are those put forward in the Environmental Protection Agency`s Environmental Standards for the Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive flasks (40 CFR 191). Much has been written about the individual building blocks that comprise the foundation of PA theory and practice, and that WIPP literature is well cited herein. However, the present approach is to provide an accurate, well documented overview of the process, from the perspective of the mechanical steps used to perform the actual PA calculations. Specifically, the preliminary stochastic simulations that comprise the WIPP PAs of 1990, 1991. and 1992 are summarized.

  15. Policy and Validity Prospects for Performance-Based Assessment.

    Science.gov (United States)

    Baker, Eva L.; And Others

    1994-01-01

    This article describes performance-based assessment as expounded by its proponents, comments on these conceptions, reviews evidence regarding the technical quality of performance-based assessment, and considers its validity under various policy options. (JDD)

  16. Conservation performance of different conservation governance regimes in the Peruvian Amazon.

    Science.gov (United States)

    Schleicher, Judith; Peres, Carlos A; Amano, Tatsuya; Llactayo, William; Leader-Williams, Nigel

    2017-09-12

    State-controlled protected areas (PAs) have dominated conservation strategies globally, yet their performance relative to other governance regimes is rarely assessed comprehensively. Furthermore, performance indicators of forest PAs are typically restricted to deforestation, although the extent of forest degradation is greater. We address these shortfalls through an empirical impact evaluation of state PAs, Indigenous Territories (ITs), and civil society and private Conservation Concessions (CCs) on deforestation and degradation throughout the Peruvian Amazon. We integrated remote-sensing data with environmental and socio-economic datasets, and used propensity-score matching to assess: (i) how deforestation and degradation varied across governance regimes between 2006-2011; (ii) their proximate drivers; and (iii) whether state PAs, CCs and ITs avoided deforestation and degradation compared with logging and mining concessions, and the unprotected landscape. CCs, state PAs, and ITs all avoided deforestation and degradation compared to analogous areas in the unprotected landscape. CCs and ITs were on average more effective in this respect than state PAs, showing that local governance can be equally or more effective than centralized state regimes. However, there were no consistent differences between conservation governance regimes when matched to logging and mining concessions. Future impact assessments would therefore benefit from further disentangling governance regimes across unprotected land.

  17. Human performance assessment: methods and measures

    International Nuclear Information System (INIS)

    Andresen, Gisle; Droeivoldsmo, Asgeir

    2000-10-01

    The Human Error Analysis Project (HEAP) was initiated in 1994. The aim of the project was to acquire insights on how and why cognitive errors occur when operators are engaged in problem solving in advanced integrated control rooms. Since human error had not been studied in the HAlden Man-Machine LABoratory (HAMMLAB) before, it was also necessary to carry out research in methodology. In retrospect, it is clear that much of the methodological work is relevant to human-machine research in general, and not only to research on human error. The purpose of this report is, therefore, to give practitioners and researchers an overview of the methodological parts of HEAP. The scope of the report is limited to methods used throughout the data acquisition process, i.e., data-collection methods, data-refinement methods, and measurement methods. The data-collection methods include various types of verbal protocols, simulator logs, questionnaires, and interviews. Data-refinement methods involve different applications of the Eyecon system, a flexible data-refinement tool, and small computer programs used for rearranging, reformatting, and aggregating raw-data. Measurement methods involve assessment of diagnostic behaviour, erroneous actions, complexity, task/system performance, situation awareness, and workload. The report concludes that the data-collection methods are generally both reliable and efficient. The data-refinement methods, however, should be easier to use in order to facilitate explorative analyses. Although the series of experiments provided an opportunity for measurement validation, there are still uncertainties connected to several measures, due to their reliability still being unknown. (Author). 58 refs.,7 tabs

  18. Technical Approach for Determining Key Parameters Needed for Modeling the Performance of Cast Stone for the Integrated Disposal Facility Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Yabusaki, Steven B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Serne, R. Jeffrey [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rockhold, Mark L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Guohui [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westsik, Joseph H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-30

    Washington River Protection Solutions (WRPS) and its contractors at Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) are conducting a development program to develop / refine the cementitious waste form for the wastes treated at the ETF and to provide the data needed to support the IDF PA. This technical approach document is intended to provide guidance to the cementitious waste form development program with respect to the waste form characterization and testing information needed to support the IDF PA. At the time of the preparation of this technical approach document, the IDF PA effort is just getting started and the approach to analyze the performance of the cementitious waste form has not been determined. Therefore, this document looks at a number of different approaches for evaluating the waste form performance and describes the testing needed to provide data for each approach. Though the approach addresses a cementitious secondary aqueous waste form, it is applicable to other waste forms such as Cast Stone for supplemental immobilization of Hanford LAW. The performance of Cast Stone as a physical and chemical barrier to the release of contaminants of concern (COCs) from solidification of Hanford liquid low activity waste (LAW) and secondary wastes processed through the Effluent Treatment Facility (ETF) is of critical importance to the Hanford Integrated Disposal Facility (IDF) total system performance assessment (TSPA). The effectiveness of cementitious waste forms as a barrier to COC release is expected to evolve with time. PA modeling must therefore anticipate and address processes, properties, and conditions that alter the physical and chemical controls on COC transport in the cementitious waste forms over time. Most organizations responsible for disposal facility operation and their regulators support an iterative hierarchical safety/performance assessment approach with a general philosophy that modeling provides

  19. Teachers' Views on Performance-Based Assessments.

    Science.gov (United States)

    King, Bruce

    1991-01-01

    Provides personal perspectives from teachers about the prospects and problems illuminated by Stanford University's Teacher Assessment Project. Teacher remarks address the portfolio development process, assessment centers, implications for national board certification for teachers, personal thoughts and perspectives on teaching, and the future of…

  20. US DOE-EM On-Site Disposal Cell Working Group - Fostering Communication On Performance Assessment Challenges

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, Roger R. [Savannah River Site (SRS), Aiken, SC (United States); Suttora, Linda C. [U.S. Department of Energy, Office of Site Restoration, Germantown, MD (United States); Phifer, Mark [Savannah River Site (SRS), Aiken, SC (United States)

    2014-03-01

    On-site disposal cells are in use and being considered at several U.S. Department of Energy (USDOE) sites as the final disposition for large amounts of waste associated with cleanup of contaminated areas and facilities. These facilities are typically developed with regulatory oversight from States and/or the US Environmental Protection Agency (USEPA) in addition to USDOE. The facilities are developed to meet design standards for disposal of hazardous waste as well as the USDOE performance based standards for disposal of radioactive waste. The involvement of multiple and different regulators for facilities across separate sites has resulted in some differences in expectations for performance assessments and risk assessments (PA/RA) that are developed for the disposal facilities. The USDOE-EM Office of Site Restoration formed a working group to foster improved communication and sharing of information for personnel associated with these Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) disposal cells and work towards more consistent assumptions, as appropriate, for technical and policy considerations related to performance and risk assessments in support of a Record of Decision and Disposal Authorization Statement. The working group holds teleconferences, as needed, focusing on specific topics of interest. The topics addressed to date include an assessment of the assumptions used for performance assessments and risk assessments (PA/RAs) for on-site disposal cells, requirements and assumptions related to assessment of inadvertent intrusion, DOE Manual 435.1-1 requirements, and approaches for consideration of the long-term performance of liners and covers in the context of PAs. The working group has improved communication among the staff and oversight personnel responsible for onsite disposal cells and has provided a forum to identify and resolve common concerns.

  1. Energy performance assessment in urban planning competitions

    International Nuclear Information System (INIS)

    Eicker, Ursula; Monien, Dirk; Duminil, Éric; Nouvel, Romain

    2015-01-01

    Highlights: • Quantification of energy efficiency in urban planning. • Analysis based on 3D (city) model. • Impact evaluation of urban form on energy demand, supply and building costs. • Primary energy balance with and without inclusion of shadowing effects. - Abstract: Many cities today are committed to increase the energy efficiency of buildings and the fraction of renewables especially in new urban developments. However, quantitative data on building energy performance as a function of urban density, building compactness and orientation, building use and supply options are rarely available during the design of new cities or early scenario analysis for existing city quarters, making it difficult for cities to effectively evaluate which concepts work today and in the future. The paper proposes a methodology to assess the energy demand and supply options as a function of the availability of geometry, building standard and use data. An automated procedure was implemented to identify each building’s geometry and volume and transfer the information to a simulation tool, which then calculates heating demand and solar energy generation on roofs and facades. The simulation includes shading calculations for each segment of the façades and roofs and thus allows a very detailed quantification of the building energy demand. By applying the methodology to a case study city quarter designed in an urban competition in Munich, it could be shown how the urban design influences the energy demand of the quarter and which fractions of renewable energy can be integrated into the roofs. While the building insulation standard and use are the is most important criteria for building energy efficiency (with an impact of more than a factor 2), the exact geometrical form, compactness and urban shading effects influences the energy demand by 10–20%. On the other hand, the detailed roof geometry and orientation influences the possible solar coverage of electricity or thermal

  2. Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992

    International Nuclear Information System (INIS)

    1993-08-01

    Before disposing of transuranic radioactive waste in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments (PAs) of the WIPP for the DOE to provide interim guidance while preparing for a final compliance evaluation. This volume of the 1992 PA contains results of uncertainty and sensitivity analyses with respect to migration of gas and brine from the undisturbed repository. Additional information about the 1992 PA is provided in other volumes. Volume 1 contains an overview of WIPP PA and results of a preliminary comparison with 40 CFR 191, Subpart B. Volume 2 describes the technical basis for the performance assessment, including descriptions of the linked computational models used in the Monte Carlo analyses. Volume 3 contains the reference data base and values for input parameters used in consequence and probability modeling. Volume 4 contains uncertainty and sensitivity analyses with respect to the EPA's Environmental Standards for the Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). Finally, guidance derived from the entire 1992 PA is presented in Volume 6. Results of the 1992 uncertainty and sensitivity analyses indicate that, conditional on the modeling assumptions and the assigned parameter-value distributions, the most important parameters for which uncertainty has the potential to affect gas and brine migration from the undisturbed repository are: initial liquid saturation in the waste, anhydrite permeability, biodegradation-reaction stoichiometry, gas-generation rates for both corrosion and biodegradation under inundated conditions, and the permeability of the long-term shaft seal

  3. Performance Assessment Strategy Plan for the Geologic Repository Program

    International Nuclear Information System (INIS)

    1990-01-01

    Performance assessment is a major constituent of the program being conducted by the US Department of Energy (DOE) to develop a geologic repository. Performance assessment is the set of activities needed for quantitative evaluations to assess compliance with the performance requirements in the regulations for a geologic repository and to support the development of the repository. The strategy for these evaluations has been documented in the Performance Assessment Strategy Plan (DOE, 1989). The implementation of the performance assessment strategy is defined in this document. This paper discusses the scope and objectives of the implementation plan, the relationship of the plan to other program plans, summarizes the performance assessment areas and the integrated strategy of the performance assessment program. 1 fig., 3 tabs

  4. Structure, conduct and performance paradigm in assessing travel agency performances

    Directory of Open Access Journals (Sweden)

    Stănciulescu Gabriela Cecilia

    2017-07-01

    Full Text Available The purpose of this paper is to present and exemplify traditional and neoclassical approaches to market structure and tourism firm performance analysis. The paper tackles some of the industrial economic thinking trends which were meant to fill the gaps left by the traditional approaches. Two approaches stand out from among the industrial economic trends: SCP paradigm and game theory. The results show that the strategy tourism operators prefer is to practise high prices; however there is no certainty that the competitors would adhere to such an idea at the beginning or during the season.

  5. Performance assessment strategy for low-level waste disposal sites

    International Nuclear Information System (INIS)

    Starmer, R.J.; Deering, L.G.; Weber, M.F.

    1988-01-01

    This paper describes US Nuclear Regulatory Commission (NRC) staff views on predicting the performance of low-level radioactive waste disposal facilities. Under the Atomic Energy Act, as amended, and the Low Level Radioactive Waste Policy Act, as amended, the NRC and Agreement States license land disposal of low-level radioactive waste (LLW) using the requirements in 10 CFR Part 61 or comparable state requirements. The purpose of this paper is to briefly describe regulatory requirements for performance assessment in low-level waste licensing, a strategy for performance assessments to support license applications, and NRC staff licensing evaluation of performance assessments. NRC's current activities in developing a performance assessment methodology will provide an overall systems modeling approach for assessing the performance of LLW disposal facilities. NRC staff will use the methodology to evaluate performance assessments conducted by applicants for LLW disposal facilities. The methodology will be made available to states and other interested parties

  6. Technical Basis for Assessing Uranium Bioremediation Performance

    International Nuclear Information System (INIS)

    PE Long; SB Yabusaki; PD Meyer; CJ Murray; AL N'Guessan

    2008-01-01

    In situ bioremediation of uranium holds significant promise for effective stabilization of U(VI) from groundwater at reduced cost compared to conventional pump and treat. This promise is unlikely to be realized unless researchers and practitioners successfully predict and demonstrate the long-term effectiveness of uranium bioremediation protocols. Field research to date has focused on both proof of principle and a mechanistic level of understanding. Current practice typically involves an engineering approach using proprietary amendments that focuses mainly on monitoring U(VI) concentration for a limited time period. Given the complexity of uranium biogeochemistry and uranium secondary minerals, and the lack of documented case studies, a systematic monitoring approach using multiple performance indicators is needed. This document provides an overview of uranium bioremediation, summarizes design considerations, and identifies and prioritizes field performance indicators for the application of uranium bioremediation. The performance indicators provided as part of this document are based on current biogeochemical understanding of uranium and will enable practitioners to monitor the performance of their system and make a strong case to clients, regulators, and the public that the future performance of the system can be assured and changes in performance addressed as needed. The performance indicators established by this document and the information gained by using these indicators do add to the cost of uranium bioremediation. However, they are vital to the long-term success of the application of uranium bioremediation and provide a significant assurance that regulatory goals will be met. The document also emphasizes the need for systematic development of key information from bench scale tests and pilot scales tests prior to full-scale implementation

  7. Technical Basis for Assessing Uranium Bioremediation Performance

    Energy Technology Data Exchange (ETDEWEB)

    PE Long; SB Yabusaki; PD Meyer; CJ Murray; AL N’Guessan

    2008-04-01

    In situ bioremediation of uranium holds significant promise for effective stabilization of U(VI) from groundwater at reduced cost compared to conventional pump and treat. This promise is unlikely to be realized unless researchers and practitioners successfully predict and demonstrate the long-term effectiveness of uranium bioremediation protocols. Field research to date has focused on both proof of principle and a mechanistic level of understanding. Current practice typically involves an engineering approach using proprietary amendments that focuses mainly on monitoring U(VI) concentration for a limited time period. Given the complexity of uranium biogeochemistry and uranium secondary minerals, and the lack of documented case studies, a systematic monitoring approach using multiple performance indicators is needed. This document provides an overview of uranium bioremediation, summarizes design considerations, and identifies and prioritizes field performance indicators for the application of uranium bioremediation. The performance indicators provided as part of this document are based on current biogeochemical understanding of uranium and will enable practitioners to monitor the performance of their system and make a strong case to clients, regulators, and the public that the future performance of the system can be assured and changes in performance addressed as needed. The performance indicators established by this document and the information gained by using these indicators do add to the cost of uranium bioremediation. However, they are vital to the long-term success of the application of uranium bioremediation and provide a significant assurance that regulatory goals will be met. The document also emphasizes the need for systematic development of key information from bench scale tests and pilot scales tests prior to full-scale implementation.

  8. Performance assessment of Point Lepreau Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Alikhan, S [Point Lepreau Generating Station, Lepreau, NB (Canada)

    1991-04-01

    The Point Lepreau Generating Station, a 680 MWe CANDU unit, is located about 40 km southwest of the city of Saint John, New Brunswick, Canada. It was declared in-service on 1 February, 1983 and, since then, has demonstrated an average cross capacity factor of over 93% up to the end of 1990. This paper compared the performance of the station with other sister CANDU units and the Light Water Reactors world-wide using the following ten performance indicators, as applicable: - gross capacity factor; - fuel burn-up; - heavy water upkeep; - unplanned reactor trips while critical; - forced outage rate; - fuel handling performance; - derived emission of radioactive effluents to environment; - personnel radiation dose; - industrial safety; - low-level solid radioactive wastes. The paper examines various areas of station activities including management and organization, operations and maintenance, technical support, fuel handling and health physics in order to highlight some of the 'good practices' which are believed to have made a significant contribution towards achieving the demonstrated performance of Point Lepreau G.S. In addition, several areas of potential improvement are discussed in order to maintain and enhance, where practicable, the safety, reliability and economic performance of the station. In this context, a careful review of the operating experiences, both in-house and at other stations, and a judicious application of lessons learned plays a significant role. (author)

  9. Performance assessment of Point Lepreau Generating Station

    International Nuclear Information System (INIS)

    Alikhan, S.

    1991-01-01

    The Point Lepreau Generating Station, a 680 MWe CANDU unit, is located about 40 km southwest of the city of Saint John, New Brunswick, Canada. It was declared in-service on 1 February, 1983 and, since then, has demonstrated an average cross capacity factor of over 93% up to the end of 1990. This paper compared the performance of the station with other sister CANDU units and the Light Water Reactors world-wide using the following ten performance indicators, as applicable: - gross capacity factor; - fuel burn-up; - heavy water upkeep; - unplanned reactor trips while critical; - forced outage rate; - fuel handling performance; - derived emission of radioactive effluents to environment; - personnel radiation dose; - industrial safety; - low-level solid radioactive wastes. The paper examines various areas of station activities including management and organization, operations and maintenance, technical support, fuel handling and health physics in order to highlight some of the 'good practices' which are believed to have made a significant contribution towards achieving the demonstrated performance of Point Lepreau G.S. In addition, several areas of potential improvement are discussed in order to maintain and enhance, where practicable, the safety, reliability and economic performance of the station. In this context, a careful review of the operating experiences, both in-house and at other stations, and a judicious application of lessons learned plays a significant role. (author)

  10. PERFORMANCE ASSESSMENT IN OPERATING DRY PORTS

    Directory of Open Access Journals (Sweden)

    Ciortescu Cezar-Gabriel

    2010-12-01

    Full Text Available In this paper, an approach for recognizing and defining correct and operable performance will be presented with the purpose of evaluating the effectiveness and efficiency of processes in dry ports (inland intermodal hubs. The challenge in evaluating the possible improvements of the underlying processes lies in the special nature and the complex structure of dry ports. It is important to consider that all the processes are highly interconnected and that changes in parameters in one process also have an impact on parameters in other processes. Furthermore, the performance of dry ports, seen as the backbone of the system, has a significant impact on the overall performance of the whole transportation network.

  11. ANALISIS KUALITAS PELAYANAN PAS BANDARA INTERNASIONAL NGURAH RAI DENGAN MENGGUNAKAN MODEL SERVQUAL

    Directory of Open Access Journals (Sweden)

    I Made Suska V

    2013-03-01

    Full Text Available Permit to a person to enter the restricted area at Ngurah Rai Airport which is called Airport Pas can be given in accordance with the duties and activities of a person at the airport. On permit service, there are disappointments and complaints of the Pas applicant that can still be found in the Pas service like duration of Pas completion and officer service at the time of application. The different perception and expectation of Pas applicant must remain in the regulation corridors and prioritize security at airports. The purpose of this research is assesing the quality of Pas service in the Airport Authority Region IV by using a SERVQUAL (Service Quality model. The model is comparing the two main factors, namely real customer perception of the service that they received (Perceived Service with the actual services expected/desirable (Expected Service which consists of 5 (five dimensions, those are Tangibles (physical, Reliability, Responsiveness, Assurance and Empathy (attention. By using these models, it is known that the quality of Pas service in the Airport Authority Region IV is still less than the expectations of the applicant and the most important dimension to enhance is Responsiveness. Gaps between perception and expectation as follows: Responsiveness (-0,2240, Assurance (-0,2171, Reliability (-0,2099, Tangibles (-0,1994, dan Empathy (-0,1373.

  12. CEMENTITIOUS BARRIERS MODELING FOR PERFORMANCE ASSESSMENTS OF SHALLOW LAND BURIAL OF LOW LEVEL RADIOACTIVE WASTE - 9243

    International Nuclear Information System (INIS)

    Taylor, G.

    2009-01-01

    The Cementitious Barriers Partnership (CBP) was created to develop predictive capabilities for the aging of cementitious barriers over long timeframes. The CBP is a multi-agency, multi-national consortium working under a U.S. Department of Energy (DOE) Environmental Management (EM-21) funded Cooperative Research and Development Agreement (CRADA) with the Savannah River National Laboratory (SRNL) as the lead laboratory. Members of the CBP are SRNL, Vanderbilt University, the U.S. Nuclear Regulatory Commission (USNRC), National Institute of Standards and Technology (NIST), SIMCO Technologies, Inc. (Canada), and the Energy Research Centre of the Netherlands (ECN). A first step in developing advanced tools is to determine the current state-of-the-art. A review has been undertaken to assess the treatment of cementitious barriers in Performance Assessments (PA). Representatives of US DOE sites which have PAs for their low level waste disposal facilities were contacted. These sites are the Idaho National Laboratory, Oak Ridge National Laboratory, Los Alamos National Laboratory, Nevada Test Site, and Hanford. Several of the more arid sites did not employ cementitious barriers. Of those sites which do employ cementitious barriers, a wide range of treatment of the barriers in a PA was present. Some sites used conservative, simplistic models that even though conservative still showed compliance with disposal limits. Other sites used much more detailed models to demonstrate compliance. These more detailed models tend to be correlation-based rather than mechanistically-based. With the US DOE's Low Level Waste Disposal Federal Review Group (LFRG) moving towards embracing a risk-based, best estimate with an uncertainties type of analysis, the conservative treatment of the cementitious barriers seems to be obviated. The CBP is creating a tool that adheres to the LFRG chairman's paradigm of continuous improvement

  13. Irrigation performance assessment in Crimea, Ukraine

    NARCIS (Netherlands)

    Pavlov, S.S.; Roerink, G.J.; Hellegers, P.J.G.J.; Popovych, V.F.

    2006-01-01

    After the collapse of the Soviet Union the performance of irrigated agriculture decreased drastically in Ukraine, due to problems related to the transition from a centrally planned economy to a market economy. Before formulating recommendations on required actions to modify this problematic

  14. Using urbanization profiles to assess screening performance

    NARCIS (Netherlands)

    Boon, ME; Kok, LP

    The large Dutch data sets acquired as a result of population-based cervical smear screening programs can be further exploited to obtain an urbanization-weighted score to gain insight into the quality of the performance of the individual cytology laboratories. Based on the first four digits of the

  15. Assessing heat exchanger performance data using temperature ...

    African Journals Online (AJOL)

    In addition, any calculated performance acceptance criteria must also consider uncertainty and error in the experimental measurements of temperature and flow. However, most statistical methods are complex and not easily applied to heat exchangers such as those that serve the power plant industry where data are difficult ...

  16. Tajikistan - Public Expenditure and Financial Accountability Assessment : Performance Report

    OpenAIRE

    World Bank

    2007-01-01

    This assessment is based on work undertaken between October 2006 and May 2007. The summary assessment covers the following three areas: an integrated assessment of PFM performance based on the 28+3 PEFA indicators, an assessment of the impact of PFM weaknesses, and the prospects for reform planning and implementation. The main report consists of four sections: an introduction, the country ...

  17. H2O2 production rate in Lactobacillus johnsonii is modulated via the interplay of a heterodimeric flavin oxidoreductase with a soluble 28 Kd PAS domain containing protein.

    Science.gov (United States)

    Valladares, Ricardo B; Graves, Christina; Wright, Kaitlyn; Gardner, Christopher L; Lorca, Graciela L; Gonzalez, Claudio F

    2015-01-01

    Host and commensals crosstalk, mediated by reactive oxygen species (ROS), has triggered a growing scientific interest to understand the mechanisms governing such interaction. However, the majority of the scientific studies published do not evaluate the ROS production by commensals bacteria. In this context we recently showed that Lactobacillus johnsonii N6.2, a strain of probiotic value, modulates the activity of the critical enzymes 2,3-indoleamine dioxygenase via H2O2 production. L. johnsonii N6.2 by decreasing IDO activity, is able to modify the tryptophan/kynurenine ratio in the host blood with further systemic consequences. Understanding the mechanisms of H2O2 production is critical to predict the probiotic value of these strains and to optimize bacterial biomass production in industrial processes. We performed a transcriptome analysis to identify genes differentially expressed in L. johnsonii N6.2 cells collected from cultures grown under different aeration conditions. Herein we described the biochemical characteristics of a heterodimeric FMN reductase (FRedA/B) whose in vitro activity is controlled by LjPAS protein with a typical Per-Arnst-Sim (PAS) sensor domain. Interestingly, LjPAS is fused to the FMN reductase domains in other lactobacillaceae. In L. johnsonii, LjPAS is encoded by an independent gene which expression is repressed under anaerobic conditions (>3 fold). Purified LjPAS was able to slow down the FRedA/B initial activity rate when the holoenzyme precursors (FredA, FredB, and FMN) were mixed in vitro. Altogether the results obtained suggest that LjPAS module regulates the H2O2 production helping the cells to minimize oxidative stress in response to environmental conditions.

  18. H2O2 production rate in Lactobacillus johnsonii is modulated via the interplay of a heterodimeric flavin oxidoreductase with a soluble 28 Kd PAS domain containing protein.

    Directory of Open Access Journals (Sweden)

    Ricardo B Valladares

    2015-07-01

    Full Text Available Host and commensals crosstalk, mediated by reactive oxygen species (ROS, has triggered a growing scientific interest to understand the mechanisms governing such interaction. However, the majority of the scientific studies published do not evaluate the ROS production by commensals bacteria. In this context we recently showed that Lactobacillus johnsonii N6.2, a strain of probiotic value, modulates the activity of the critical enzymes 2,3-indoleamine dioxygenase via H2O2 production. L. johnsonii N6.2 by decreasing IDO activity, is able to modify the tryptophan/kynurenine ratio in the host blood with further systemic consequences. Understanding the mechanisms of H2O2 production is critical to predict the probiotic value of these strains and to optimize bacterial biomass production in industrial processes. We performed a transcriptome analysis to identify genes differentially expressed in L. johnsonii N6.2 cells collected from cultures grown under different aeration conditions. Herein we described the biochemical characteristics of a heterodimeric FMN reductase (FRedA/B whose in vitro activity is controlled by LjPAS protein with a typical Per-Arnst-Sim (PAS sensor domain. Interestingly, LjPAS is fused to the FMN reductase domains in other lactobacillaceae. In L. johnsonii, LjPAS is encoded by an independent gene which expression is repressed under anaerobic conditions (>3 fold. Purified LjPAS was able to slow down the FRedA/B initial activity rate when the holoenzyme precursors (FredA, FredB and FMN were mixed in vitro. Altogether the results obtained suggest that LjPAS module regulates the H2O2 production helping the cells to minimize oxidative stress in response to environmental conditions.

  19. Nitrogen Approach Program. In line with the European law?; Aanpak van stikstof. Europeesrechtelijk in de pas?

    Energy Technology Data Exchange (ETDEWEB)

    Schrijnemaekers, J.; Van der Sluis, C. [Ploum Lodder Princen, Rotterdam (Netherlands)

    2011-02-15

    Nitrogen deposition is causing problems in protected areas designated by the Natural 2000 program with a view to protect biodiversity . To deal with these problems the Dutch government developed the Programmatic Approach to Nitrogen (Programmatische Aanpak Stikstof - PAS). This approach is discussed in this article. [Dutch] De depositie van stikstof in gebieden waarvoor het zogenaamde Natura 2000 programma de biodiversiteit moet beschermen zorgt voor problemen. Om de problemen het hoofd te bieden heeft de Nederlandse overheid de Programmatische Aanpak Stikstof (PAS) ontwikkeld. In dit artikel wordt aandacht besteed aan PAS.

  20. WIPP performance assessment: impacts of human intrusion

    International Nuclear Information System (INIS)

    Anderson, D.R.; Hunter, R.L.; Bertram-Howery, S.G.; Lappin, A.R.

    1989-01-01

    The Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico is a research and development facility that may become the USA's first and only mined geologic repository for transuranic waste. Human intrusion into the WIPP repository after closure has been shown by preliminary sensitivity analyses and calculations of consequences to be an important, and perhaps the most important, factor in long-term repository performance

  1. Cost performance assessment of in situ vitrification

    International Nuclear Information System (INIS)

    Showalter, W.E.; Letellier, B.C.; Booth, S.R.; Barnes-Smith, P.

    1992-01-01

    In situ vitrification (ISV) is a thermal treatment technology with promise for the destruction or immobilization of hazardous materials in contaminated soils. It has developed over the past decade to a level of maturity where meaningful cost effectiveness studies may be performed. The ISV process melts 4 to 25 m 2 of undisturbed soil to a maximum depth of 6 m into an obsidian-like glass waste form by applying electric current (3750 kill) between symmetrically spaced electrodes. Temperatures of approximately 2000 degree C drive off and destroy complex organics which are captured in an off-gas treatment system, while radio-nuclides are incorporated into the homogeneous glass monolith. A comparative life-cycle cost evaluation between mobile rotary kiln incineration and ISV was performed to quantitatively identify appropriate performance regimes and components of cost which are sensitive to the implementation of each technology. Predictions of melt times and power consumption were obtained from an ISV performance model over ranges of several parameters including electrode spacing, soil moisture, melt depth, electrical resistivity, and soil density. These data were coupled with manpower requirements, capitalization costs, and a melt placement optimization routine to allow interpolation over a wide variety of site characteristics. For the purpose of this study, a single site scenario representative of a mixed waste evaporation pond was constructed. Preliminary comparisons between ISV and incineration show that while operating costs are comparable, ISV avoids secondary treatment and monitored storage of radioactive waste that would be required following conventional incineration. It is the long term storage of incinerated material that is the most expensive component

  2. A lecithin phosphatidylserine and phosphatidic acid complex (PAS) reduces symptoms of the premenstrual syndrome (PMS): Results of a randomized, placebo-controlled, double-blind clinical trial.

    Science.gov (United States)

    Schmidt, Katja; Weber, Nicole; Steiner, Meir; Meyer, Nadin; Dubberke, Anne; Rutenberg, David; Hellhammer, Juliane

    2018-04-01

    Many women experience emotional and physical symptoms around the time of ovulation and more so before menstruation interfering with their daily normal life also known as premenstrual syndrome (PMS). Recent observational data suggest that supplementation with Lipogen's phosphatidylserine (PS) and phosphatidic acid (PA) complex (PAS) alleviates these PMS symptoms. The aim of this study was to confirm these observations on the effects of PAS on PMS symptom severity within a controlled clinical trial setting. Forty women aged 18-45 years with a diagnosis of PMS were assigned to either take PAS (containing 400 mg PS & 400 mg PA per day) or a matching placebo. The study comprised 5 on-site visits including 1 baseline menstrual cycle followed by 3 treatment cycles. Treatment intake was controlled for by using an electronic device, the Medication Event Monitoring System (MEMS ® ). Primary outcome of the study was the PMS symptoms severity as assessed by using the Daily Record of Severity of Problems (DRSP). Further, SIPS questionnaire (a German version of the Premenstrual Symptoms Screening Tool (PSST)), salivary hormone levels (cortisol awakening response (CAR) and evening cortisol levels) as well as serum levels (cortisol, estradiol, progesterone and corticosteroid binding globulin (CBG)) were assessed. PMS symptoms as assessed by the DRSP Total score showed a significantly better improvement (p = 0.001) over a 3 cycles PAS intake as compared to placebo. In addition, PAS treated women reported a greater improvement in physical (p = 0.002) and depressive symptoms (p = 0.068). They also reported a lower reduction of productivity (p = 0.052) and a stronger decrease in interference with relationships with others (p = 0.099) compared to the placebo group. No other DRSP scale or item showed significant results. Likewise, the reduction in the number of subjects fulfilling PMS or premenstrual dysphoric disorder (PMDD) criteria as classified by the SIPS did not

  3. Some viewpoints on reference biospheres in Finnish performance assessments

    International Nuclear Information System (INIS)

    Rasilainen, K.; Kattilakoski, E.; Suolanen, V.; Vieno, T.; Vuori, S.

    2002-01-01

    Viewpoints are presented concerning biosphere studies in performance assessments of nuclear waste disposal. The points are based on experiences from several Finnish performance assessments. The latest performance assessment for spent fuel disposal, TILA-99, was considered in the Decision in Principle process for the site selection of the repository. The points given are also based on experiences from participation in international projects dealing with biosphere modelling, for instance BIOMOVS and BIOMASS. (author)

  4. Performance objectives for the Hanford Immobilized Low-Activity Waste (ILAW) performance assessment

    International Nuclear Information System (INIS)

    MANN, F.M.

    1999-01-01

    Performance objectives for the disposal of low activity waste from Hanford Waste Tanks have been developed. These objectives have been based on DOE requirements, programmatic requirements, and public involvement. The DOE requirements include regulations that direct the performance assessment and are cited within the Radioactive Waste Management Order (DOE Order 435.1). Performance objectives for other DOE complex performance assessments have been included

  5. The role of performance assessment in radioactive waste disposal

    International Nuclear Information System (INIS)

    Stenhouse, M.J.

    1998-01-01

    Performance assessment has many applications in the field of radioactive waste management, none more important than demonstrating the suitability of a particular repository system for waste disposal. The role of performance assessment in radioactive waste disposal is discussed with reference to assessments performed in civilian waste management programmes. The process is, however, relevant, and may be applied directly to the disposal of defence-related wastes. When used in an open and transparent manner, performance assessment is a powerful methodology not only for convincing the authorities of the safety of a disposal concept, but also for gaining the wider acceptance of the general public for repository siting. 26 refs

  6. Development and validation of the Psychological Adaptation Scale (PAS): use in six studies of adaptation to a health condition or risk.

    Science.gov (United States)

    Biesecker, Barbara B; Erby, Lori H; Woolford, Samuel; Adcock, Jessica Young; Cohen, Julie S; Lamb, Amanda; Lewis, Katie V; Truitt, Megan; Turriff, Amy; Reeve, Bryce B

    2013-11-01

    We introduce The Psychological Adaptation Scale (PAS) for assessing adaptation to a chronic condition or risk and present validity data from six studies of genetic conditions. Informed by theory, we identified four domains of adaptation: effective coping, self-esteem, social integration, and spiritual/existential meaning. Items were selected from the PROMIS "positive illness impact" item bank and adapted from the Rosenberg self-esteem scale to create a 20-item scale. Each domain included five items, with four sub-scale scores. Data from studies of six populations: adults affected with or at risk for genetic conditions (N=3) and caregivers of children with genetic conditions (N=3) were analyzed using confirmatory factor analyses (CFA). CFA suggested that all but five posited items converge on the domains as designed. Invariance of the PAS amongst the studies further suggested it is a valid and reliable tool to facilitate comparisons of adaptation across conditions. Use of the PAS will standardize assessments of adaptation and foster understanding of the relationships among related health outcomes, such as quality of life and psychological well-being. Clinical interventions can be designed based on PAS data to enhance dimensions of psychological adaptation to a chronic health condition or risk. Published by Elsevier Ireland Ltd.

  7. Tools for Performance Assessment of OLSR Protocol

    Directory of Open Access Journals (Sweden)

    Makoto Ikeda

    2009-01-01

    Full Text Available In this paper, we evaluate the performance of Optimized Link State Routing (OLSR protocol by experimental and simulation results. The experiments are carried out by using our implemented testbed and the simulations by using ns-2 simulator. We also designed and implemented a new interface for the ad-hoc network testbed in order to make more easier the experiments. The comparison between experimental and simulation results shows that for the same parameters set, in the simulation we did not notice any packet loss. On the other hand, in the experiments we experienced packet loss because of the environment effects and traffic interference.

  8. Thorium fuel performance assessment in HTRs

    Energy Technology Data Exchange (ETDEWEB)

    Allelein, H.-J. [Forschungszentrum Jülich, D-52425 Jülich (Germany); RWTH Aachen, D-52072 Aachen (Germany); Kania, M.J.; Nabielek, H. [Forschungszentrum Jülich, D-52425 Jülich (Germany); Verfondern, K., E-mail: k.verfondern@fz-juelich.de [Forschungszentrum Jülich, D-52425 Jülich (Germany)

    2014-05-01

    Thorium as a nuclear fuel is receiving renewed interest, because of its widespread availability and the good irradiation performance of Th and mixed (Th,U) oxide compounds as fuels in nuclear power systems. Early HTR development employed thorium together with high-enriched uranium. After 1980, most HTR fuel systems switched to low-enriched uranium. After completing fuel development for AVR and THTR with BISO coated particles, the German program expanded efforts on a new program utilizing thorium and high-enriched uranium TRISO coated particles for advanced HTR concepts for process heat applications (PNP) and direct-cycle electricity production (HHT). The combination of LTI inner and outer pyrocarbon layers surrounding a strong, stable SiC layer greatly improved manufacturing conditions and the subsequent contamination and defective particle fractions in production fuel elements. In addition, this combination provided improved mechanical strength and a higher degree of solid fission product retention, not known previously with HTI-BISO coatings. The improved performance of the HEU (Th,U)O{sub 2} TRISO fuel system was successfully demonstrated in three primary areas of development: manufacturing, irradiation testing under normal operating conditions, and accident simulation testing. In terms of demonstrating performance for advanced HTR applications, the experimental failure statistic from manufacture and irradiation testing are significantly below the coated particle requirements specified for PNP and HHT designs at the time. Covering a range to 1300 °C in normal operations and 1600 °C in accidents, with burnups up to 13% FIMA and fast fluences to 8 × 10{sup 25} m{sup −2} (E > 16 fJ), the results exceed the design limits on manufacturing and operational requirements for the German HTR Modul concept, which were: <6.5 × 10{sup −5} for manufacturing; <2 × 10{sup −4} for normal operating conditions; and <5 × 10{sup −4} for accident conditions. These

  9. Performance Assessment as a Diagnostic Tool for Science Teachers

    Science.gov (United States)

    Kruit, Patricia; Oostdam, Ron; van den Berg, Ed; Schuitema, Jaap

    2018-04-01

    Information on students' development of science skills is essential for teachers to evaluate and improve their own education, as well as to provide adequate support and feedback to the learning process of individual students. The present study explores and discusses the use of performance assessments as a diagnostic tool for formative assessment to inform teachers and guide instruction of science skills in primary education. Three performance assessments were administered to more than 400 students in grades 5 and 6 of primary education. Students performed small experiments using real materials while following the different steps of the empirical cycle. The mutual relationship between the three performance assessments is examined to provide evidence for the value of performance assessments as useful tools for formative evaluation. Differences in response patterns are discussed, and the diagnostic value of performance assessments is illustrated with examples of individual student performances. Findings show that the performance assessments were difficult for grades 5 and 6 students but that much individual variation exists regarding the different steps of the empirical cycle. Evaluation of scores as well as a more substantive analysis of students' responses provided insight into typical errors that students make. It is concluded that performance assessments can be used as a diagnostic tool for monitoring students' skill performance as well as to support teachers in evaluating and improving their science lessons.

  10. Performance Assessment of Intelligence, Surveillance, and Reconnaissance (ISR) Enterprise Workflows

    National Research Council Canada - National Science Library

    Hurley, M. B; Jones, P. B

    2007-01-01

    ... on how to assess the performance of these systems. The framework delineates how measurements from laboratory tests, operational experiments, and field deployments can be analyzed to produce accurate, quantitative descriptions of system performance...

  11. Practical session assessments in human anatomy: Weightings and performance.

    Science.gov (United States)

    McDonald, Aaron C; Chan, Siew-Pang; Schuijers, Johannes A

    2016-07-08

    Assessment weighting within a given module can be a motivating factor for students when deciding on their commitment level and time given to study a specific topic. In this study, an analysis of assessment performances of second year anatomy students was performed over four years to determine if (1) students performed better when a higher weighting was given to a set of practical session assessments and (2) whether an improved performance in the practical session assessments had a carry-over effect on other assessment tasks within that anatomy module and/or other anatomy modules that follow. Results showed that increasing the weighting of practical session assessments improved the average mark in that assessment and also improved the percentage of students passing that assessment. Further, it significantly improved performance in the written end-semester examination within the same module and had a carry-over effect on the anatomy module taught in the next teaching period, as students performed better in subsequent practical session assessments as well as subsequent end-semester examinations. It was concluded that the weighting of assessments had significant influences on a student's performance in that, and subsequent, assessments. It is postulated that practical session assessments, designed to develop deep learning skills in anatomy, improved efficacy in student performance in assessments undertaken in that and subsequent anatomy modules when the weighting of these assessments was greater. These deep learning skills were also transferable to other methods of assessing anatomy. Anat Sci Educ 9: 330-336. © 2015 American Association of Anatomists. © 2015 American Association of Anatomists.

  12. Assessing The Performance of Hydrological Models

    Science.gov (United States)

    van der Knijff, Johan

    The performance of hydrological models is often characterized using the coefficient of efficiency, E. The sensitivity of E to extreme streamflow values, and the difficulty of deciding what value of E should be used as a threshold to identify 'good' models or model parameterizations, have proven to be serious shortcomings of this index. This paper reviews some alternative performance indices that have appeared in the litera- ture. Legates and McCabe (1999) suggested a more generalized form of E, E'(j,B). Here, j is a parameter that controls how much emphasis is put on extreme streamflow values, and B defines a benchmark or 'null hypothesis' against which the results of the model are tested. E'(j,B) was used to evaluate a large number of parameterizations of a conceptual rainfall-runoff model, using 6 different combinations of j and B. First, the effect of j and B is explained. Second, it is demonstrated how the index can be used to explicitly test hypotheses about the model and the data. This approach appears to be particularly attractive if the index is used as a likelihood measure within a GLUE-type analysis.

  13. Assessing Bus Performance Rating in Kajang, Selangor

    Science.gov (United States)

    Norhisham, S.; Ismail, A.; Sidek, L. M.; Borhan, M. N.; Zaini, N.; Yen, A. T. G.

    2018-04-01

    The Transit Capacity and Quality of Service Manual (TCQSM) was chosen based on the review with four manuals and guidelines for the method will be applied. Six (6) attributes, namely Hours of Service, Passenger Load, Transit Auto Travel Time, Service Frequency, Punctuality Performance and Service Coverage were chosen for evaluation.[6][7][8]. A total of three (3) operators with seven (7) routes were identified in Kajang. Based on the final results, the Quality of Service (QOS) findings was rated as D, which was regarded as minimum or satisfactory. Most stakeholders’ recommendations were: for the operators to provide information on bus scheduling and have accurate information for the passengers. It was suggested that in future this study can be extended to all routes and could be repeated after the opening of the Mass Rapid Transit (MRT) stations in Kajang, so as to provide a comparison and better evaluation of the public buses in Kajang.

  14. Synchronous and Cogged Fan Belt Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, Dylan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Dean, Jesse [National Renewable Energy Lab. (NREL), Golden, CO (United States); Acosta, Jason [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    The GSA Regional GPG Team commissioned the National Renewable Energy Laboratory (NREL) to perform monitoring of cogged V-belts and synchronous belts on both a constant volume and a variable air volume fan at the Byron G. Rodgers Federal Building and U.S. Courthouse in Denver, Colorado. These motor/fan combinations were tested with their original, standard V-belts (appropriately tensioned by an operation and maintenance professional) to obtain a baseline for standard operation. They were then switched to the cogged V-belts, and finally to synchronous belts. The power consumption by the motor was normalized for both fan speed and air density changes. This was necessary to ensure that the power readings were not influenced by a change in rotational fan speed or by the power required to push denser air. Finally, energy savings and operation and maintenance savings were compiled into an economic life-cycle cost analysis of the different belt options.

  15. Assessing ventilation system performance in isolation rooms

    Energy Technology Data Exchange (ETDEWEB)

    Balocco, Carla [Department of Energy Engineering ' ' Sergio Stecco' ' , via S. Marta 3, Firenze (Italy); Lio, Pietro [Computer Laboratory, University of Cambridge, 15 JJ Thompson Avenue, CB03FD Cambridge (United Kingdom)

    2011-01-15

    In this paper numerical transient simulations were used to investigate the air flow patterns, distribution and velocity, and the particulate dispersion inside an existing typical hospitalization room equipped with an advanced Heating Ventilation Air Conditioning (HVAC), with Variable Air Volume (VAV) primary air system designed for immune-suppressed patients never modelled before. The three-dimensional models of the room consider different, most typical, positions of the patients. Results indicate the best conditions for the high induction air inlet diffuser and the scheme of pressures imposed in the room to provide the effective means of controlling flows containing virus droplets. We believe that our work exemplifies the usefulness of numerical investigations of HVAC performances in real situations and provides important recommendations towards disease control and careful design and optimization of ventilation in hospital settings. (author)

  16. An Empirical Study of a Solo Performance Assessment Model

    Science.gov (United States)

    Russell, Brian E.

    2015-01-01

    The purpose of this study was to test a hypothesized model of solo music performance assessment. Specifically, this study investigates the influence of technique and musical expression on perceptions of overall performance quality. The Aural Musical Performance Quality (AMPQ) measure was created to measure overall performance quality, technique,…

  17. Crystallization and preliminary crystallographic characterization of the PAS domains of EAG and ELK potassium channels

    International Nuclear Information System (INIS)

    Adaixo, Ricardo; Morais-Cabral, João Henrique

    2010-01-01

    The N-terminal PAS domains from the eukaryotic EAG potassium channels are thought to have a regulatory function. Here the expression, purification, crystallization and preliminary crystallographic characterization of two of these domains are described. Per–Arnt–Sim (PAS) domains are ubiquitous in nature; they are ∼130-amino-acid protein domains that adopt a fairly conserved three-dimensional structure despite their low degree of sequence homology. These domains constitute the N-terminus or, less frequently, the C-terminus of a number of proteins, where they exert regulatory functions. PAS-containing proteins generally display two or more copies of this motif. In this work, the crystallization and preliminary analysis of the PAS domains of two eukaryotic potassium channels from the ether-à-go-go (EAG) family are reported

  18. ON THE MYTH OF PARENTAL ALIENATION SYNDROME (PAS AND THE DSM-5

    Directory of Open Access Journals (Sweden)

    Ramón Vilalta

    2017-09-01

    Full Text Available This paper discusses the controversy over the existence of Parental Alienation Syndrome (PAS or any other name it may be given. The negative judgements regarding PAS are diverse in nature: from criticism about the personality of the term’s creator, to the most repeated criticism that PAS does not exist in the Diagnostic and Statistical Manual of Mental Disorders DSM-5. This paper analyzes some of these criticisms in the Spanish judicial context, especially those exposed in the Guidelines of the Group of Experts on the Fight against Domestic and Gender Violence of the General Council of the Judiciary (CGPJ, published in 2016. It is argued that PAS is widely recognized by the professional and scientific community and may be described and classified in the DSM-5 as a “Parent–Child Relational Problem V61.20 (Z62.820”.

  19. How electronic health records can unmask the hidden value of PAs.

    Science.gov (United States)

    Ogunfiditimi, Folusho; Sherry, Scott P; Foote, Monica; Christie, Sarah L; Shock, Lisa P; Cawley, James; Browne, Aaron

    2017-06-01

    The Fee for Value (FFV) Task Force, a subgroup of the American Academy of PAs' Research and Strategic Initiatives Commission, has examined tools and mechanisms aimed at better clarifying the volume and value of PA work and how that work contributes to improving access to high-quality care. Establishing the value of PAs has been a challenging task for many healthcare providers. Often, PA value has been defined by their clinical productivity, without any clear direction as to what constitutes value versus productivity. The objective of this article is to unmask the value of PAs through the role of electronic health records and highlight PAs' ability to produce services that are value-oriented and quantifiably productive.

  20. EGF increases expression and activity of PAs in preimplantation rat embryos and their implantation rate

    Directory of Open Access Journals (Sweden)

    Har-Vardi Iris

    2007-01-01

    Full Text Available Abstract Background Embryo implantation plays a major role in embryogenesis and the outcome of pregnancy. Plasminogen activators (PAs have been implicated in mammalian fertilization, early stages of development and embryo implantation. As in-vitro developing embryos resulted in lower implantation rate than those developed in-vivo we assume that a reduced PAs activity may be involved. In the present work we studied the effect of EGF on PAs activity, quantity and embryo implantation. Methods Zygotes were flushed from rat oviducts on day one of pregnancy and grown in-vitro in R1ECM supplemented with EGF (10 ng/ml and were grown up to the blastocyst stage. The control groups were grown in the same medium without EGF. The distribution and quantity of the PAs were examined using fluorescence immunohistochemistry followed by measurement of PAs activity using the chromogenic assay. Implantation rate was studied using the embryo donation model. Results PAs distribution in the embryos was the same in EGF treated and untreated embryos. Both PAs were localized in the blastocysts' trophectoderm, supporting the assumption that PAs play a role in the implantation process in rats. EGF increased the quantity of uPA at all stages studied but the 8-cell stage as compared with controls. The tissue type PA (tPA content was unaffected except the 8-cell stage, which was increased. The activity of uPA increased gradually towards the blastocyst stage and more so due to the presence of EGF. The activity of tPA did not vary with the advancing developmental stages although it was also increased by EGF. The presence of EGF during the preimplantation development doubled the rate of implantation of the treated group as compared with controls.

  1. Performance Assessment Program for the Savannah River Site Liquid Waste Facilities - 13610

    International Nuclear Information System (INIS)

    Rosenberger, Kent H.

    2013-01-01

    The Liquid Waste facilities at the U.S. Department of Energy's (DOE) Savannah River Site (SRS) are operated by Liquid Waste Operations contractor Savannah River Remediation LLC (SRR). A separate Performance Assessment (PA) is prepared to support disposal operations at the Saltstone Disposal Facility and closure evaluations for the two liquid waste tank farm facilities at SRS, F-Tank Farm and H-Tank Farm. A PA provides the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements identified in operations and closure regulatory guidance. The Saltstone Disposal Facility is subject to a State of South Carolina industrial solid waste landfill permit and the tank farms are subject to a state industrial waste water permit. The three Liquid Waste facilities are also subject to a Federal Facility Agreement approved by the State, DOE and the Environmental Protection Agency (EPA). Due to the regulatory structure, a PA is a key technical document reviewed by the DOE, the State of South Carolina and the EPA. As the waste material disposed of in the Saltstone Disposal Facility and the residual material in the closed tank farms is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005, the U.S. Nuclear Regulatory Commission (NRC) is also a reviewing agency for the PAs. Pursuant to the Act, the NRC also has a continuing role to monitor disposal actions to assess compliance with stated performance objectives. The Liquid Waste PA program at SRS represents a continual process over the life of the disposal and closure operations. When the need for a PA or PA revision is identified, the first step is to develop a conceptual model to best represent the facility conditions. The conceptual model will include physical dimensions of the closed system, both the engineered and natural system, and modeling

  2. Performance Assessment Program for the Savannah River Site Liquid Waste Facilities - 13610

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberger, Kent H. [Savannah River Remediation LLC, Building 705-1C, Aiken, SC 29808 (United States)

    2013-07-01

    The Liquid Waste facilities at the U.S. Department of Energy's (DOE) Savannah River Site (SRS) are operated by Liquid Waste Operations contractor Savannah River Remediation LLC (SRR). A separate Performance Assessment (PA) is prepared to support disposal operations at the Saltstone Disposal Facility and closure evaluations for the two liquid waste tank farm facilities at SRS, F-Tank Farm and H-Tank Farm. A PA provides the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements identified in operations and closure regulatory guidance. The Saltstone Disposal Facility is subject to a State of South Carolina industrial solid waste landfill permit and the tank farms are subject to a state industrial waste water permit. The three Liquid Waste facilities are also subject to a Federal Facility Agreement approved by the State, DOE and the Environmental Protection Agency (EPA). Due to the regulatory structure, a PA is a key technical document reviewed by the DOE, the State of South Carolina and the EPA. As the waste material disposed of in the Saltstone Disposal Facility and the residual material in the closed tank farms is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005, the U.S. Nuclear Regulatory Commission (NRC) is also a reviewing agency for the PAs. Pursuant to the Act, the NRC also has a continuing role to monitor disposal actions to assess compliance with stated performance objectives. The Liquid Waste PA program at SRS represents a continual process over the life of the disposal and closure operations. When the need for a PA or PA revision is identified, the first step is to develop a conceptual model to best represent the facility conditions. The conceptual model will include physical dimensions of the closed system, both the engineered and natural system, and

  3. Les scientifiques du CERN n'oublient pas l'Irak pour eux, les préoccupations humanitaires n'ont pas de passeport

    CERN Multimedia

    2003-01-01

    Scientists from the CERN club ConCERNed for Humanity have written to the Swiss Federal Councellor, Micheline Calmy-Rey, with 550 signatures on a petition "pas en notre nom" - not in our name - to ask her to do all that is in her capacity to end the conflict in Iraq (0.5 page)

  4. Peer mentoring in doctor performance assessment: strategies, obstacles and benefits.

    NARCIS (Netherlands)

    Overeem, K.; Driessen, E.W.; Arah, O.A.; Lombarts, K.M.; Wollersheim, H.C.H.; Grol, R.P.T.M.

    2010-01-01

    CONTEXT: Mentors are increasingly involved in doctor performance assessments. Mentoring seems to be a key determinant in achieving the ultimate goal of those assessments, namely, improving doctor performance. Little is known, however, about how mentors perceive and fulfil this role. OBJECTIVE: The

  5. Peer mentoring in doctor performance assessment: strategies, obstacles and benefits

    NARCIS (Netherlands)

    Overeem, Karlijn; Driessen, Erik W.; Arah, Onyebuchi A.; Lombarts, Kiki M. J. M. H.; Wollersheim, Hub C.; Grol, Richard P. T. M.

    2010-01-01

    CONTEXT: Mentors are increasingly involved in doctor performance assessments. Mentoring seems to be a key determinant in achieving the ultimate goal of those assessments, namely, improving doctor performance. Little is known, however, about how mentors perceive and fulfil this role. OBJECTIVE: The

  6. Les sciences cognitives ne sont pas des sciences humaines

    Directory of Open Access Journals (Sweden)

    Albert Ogien

    2011-10-01

    Full Text Available Cet article analyse les limites du naturalisme social que Laurence Kaufman et Laurent Cordonier proposent d’adopter dans cette même revue, en critiquant leur plaidoyer pour l’intégration des savoirs des sciences cognitives et des sciences humaines et sociales. Cette critique repose sur la réfutation de trois idées soutenues par les auteurs : 1 la description scientifique des mécanismes cognitifs élémentaires fournit une explication causale des conduites sociales qui doit se substituer à celles des sciences humaines et sociales ; 2 le recours au naturalisme permet de falsifier les préconceptions que ces dernières continuent à entretenir ; 3 le programme de naturalisation de l’esprit n’implique aucune forme de réductionnisme. Cette triple critique permet de rejeter leur appel en faveur d’un modèle intégré de la conduite humaine, en avançant un constat : dans la mesure où on ne sait pas comment combler le hiatus qui sépare les descriptions détaillées du cerveau au travail de l’explication des conduites des individus et de la manière dont ils en assurent la coordination dans le temps même où ils agissent en commun, les sciences humaines et sociales ont peu de choses à aller glaner du côté des sciences cognitives pour améliorer la manière dont elles analysent l’action. C’est que le travail de celles-ci se situe soit au niveau infra-humain du fonctionnement moléculaire, soit au niveau supra-humain de l’évolution ; et que seules les sciences humaines et sociales placent leurs analyses à un niveau simplement humain, en faisant des individus tels qu’ils vivent ensemble la mesure de toutes les choses qui les concernent. Ce qu’elles ne peuvent faire sur un mode naturaliste.Cognitive sciences are not social sciencesThis article examines the limits of the social naturalism proposed by Laurence Kauffman and Laurent Cordonier in this journal by criticizing their plea concerning knowledge integration of

  7. Performance Assessment Framework for Private Finance Initiative Projects in Malaysia

    Directory of Open Access Journals (Sweden)

    Lop Nor Suzila

    2016-01-01

    Full Text Available Private Finance Initiative (PFI is viewed as restructuring the previous privatisation concept in delivering value for money for the Malaysian public infrastructure. Among the restructuring efforts in the privatisation is specifying the standard assessment of private concessionaires’ performance through the execution of key performance indicators (KPIs where the private concessionaires’ performance is benchmarked against the government’s standard. KPIs have served as useful tools in assessing performance of PFI projects. However, there is still lacking on determination methods performed to define and measure this KPIs and the absence of guidelines or a framework is also an issue in the implementation of the PFI procurement in Malaysia. Therefore, the objectives of this paper is to investigate the notion of performance assessment model approaches globally (i.e. UK, China, Australia, Serbia and Malaysia and to identify direction for PFI performance assessment tools (KPIs to be practiced in Malaysia. Based on the consideration of these models, this research paper propose an initial framework of performance assessment for PFI projects in Malaysia. The framework is deliberate to cover the performance of PFI at the operation and maintenance phase. The outcomes of this paper can serve as a theoretical base for the development of comprehensive and effective performance assessment for PFI projects in Malaysia.

  8. An analysis of characteristics of post-authorisation studies registered on the ENCePP EU PAS Register [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Robert Carroll

    2017-11-01

    Full Text Available Background: The objective of this study was to investigate the study design characteristics of Post-Authorisation Studies (PAS requested by the European Medicines Agency which were recorded on the European Union (EU PAS Register held by the European Network of Centres for Pharmacoepidemiology and Pharmacovigilance (ENCePP. Methods: We undertook a cross-sectional descriptive analysis of all studies registered on the EU PAS Register as of 18th October 2016. Results: We identified a total of 314 studies on the EU PAS Register, including 81 (26% finalised, 160 (51% ongoing and 73 (23% planned. Of those studies identified, 205 (65% included risk assessment in their scope, 133 (42% included drug utilisation and 94 (30% included effectiveness evaluation. Just over half of the studies (175; 56% used primary data capture, 135 (43% used secondary data and 4 (1% used a hybrid design combining both approaches. Risk assessment and effectiveness studies were more likely to use primary data capture (60% and 85% respectively as compared to 39% and 14% respectively for secondary. The converse was true for drug utilisation studies where 59% were secondary vs. 39% for primary. For type 2 diabetes mellitus, database studies were more commonly used (80% vs 3% chart review, 3% hybrid and 13% primary data capture study designs whereas for studies in oncology, primary data capture were more likely to be used (85% vs 4% chart review, and 11% database study designs. Conclusions: Results of this analysis show that PAS design varies according to study objectives and therapeutic area.

  9. Determination of Safety Performance Grade of NPP Using Integrated Safety Performance Assessment (ISPA) Program

    International Nuclear Information System (INIS)

    Chung, Dae Wook

    2011-01-01

    Since the beginning of 2000, the safety regulation of nuclear power plant (NPP) has been challenged to be conducted more reasonable, effective and efficient way using risk and performance information. In the United States, USNRC established Reactor Oversight Process (ROP) in 2000 for improving the effectiveness of safety regulation of operating NPPs. The main idea of ROP is to classify the NPPs into 5 categories based on the results of safety performance assessment and to conduct graded regulatory programs according to categorization, which might be interpreted as 'Graded Regulation'. However, the classification of safety performance categories is highly comprehensive and sensitive process so that safety performance assessment program should be prepared in integrated, objective and quantitative manner. Furthermore, the results of assessment should characterize and categorize the actual level of safety performance of specific NPP, integrating all the substantial elements for assessing the safety performance. In consideration of particular regulatory environment in Korea, the integrated safety performance assessment (ISPA) program is being under development for the use in the determination of safety performance grade (SPG) of a NPP. The ISPA program consists of 6 individual assessment programs (4 quantitative and 2 qualitative) which cover the overall safety performance of NPP. Some of the assessment programs which are already implemented are used directly or modified for incorporating risk aspects. The others which are not existing regulatory programs are newly developed. Eventually, all the assessment results from individual assessment programs are produced and integrated to determine the safety performance grade of a specific NPP

  10. Performance Assessment of Communication Enhancement Devices TEA HI Threat Headset

    Science.gov (United States)

    2015-08-01

    AFRL-RH-WP-TR-2015-0076 Performance Assessment of Communication Enhancement Devices: TEA HI Threat Headset Hilary L. Gallagher...of Communication Enhancement Devices: TEA HI Threat Headset 5a. CONTRACT NUMBER FA8650-14-D-6501 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER...technology in military applications. Objective performance data provided an assessment of the performance of these devices. The TEA HI Threat headset

  11. The Empirical Testing of a Musical Performance Assessment Paradigm

    Science.gov (United States)

    Russell, Brian E.

    2010-01-01

    The purpose of this study was to test a hypothesized model of aurally perceived performer-controlled musical factors that influence assessments of performance quality. Previous research studies on musical performance constructs, musical achievement, musical expression, and scale construction were examined to identify the factors that influence…

  12. The link between performance assessment and quality of data

    International Nuclear Information System (INIS)

    Csullog, G.W.

    1990-11-01

    Performance assessments, using both individual and cumulative inventories, produce estimates of the risk or dose consequences for repository concepts. Unacceptable risk or dose for a given contaminant identify it as a problem contaminant. While risk or dose consequences are common outputs of safety assessments, results can also be reported as estimates of the safe inventory limit for each contaminant in a repository scenario. Once problem contaminants are identified, it may be useful to: validate the data used in the performance assessment; restrict contaminant inventories in the repository; or, improve the containment capability of the repository (including improved packaging). A key point is that performance assessments define the quality of data to be collected. If a contaminant's inventory will be far below its estimated safe inventory limit for a repository, then it is reasonable to accept inventory estimates that have high variances and low confidence. For contaminants that have a significant impact upon performance assessments, efforts must be made to provide the best inventory (source term) estimates practicable. One important goal of characterization programs should be to establish the adequacy of data used in performance assessments. There is little value in striving to improve confidence in data for some waste streams if they are assessed to have a minor impact upon repository performance. Streams that have a major impact upon performance deserve the time, attention and money to be characterized adequately. Waste acceptance must be linked to the quality of characterization data provided by generators. This link sets compliance monitoring requirements

  13. Comparative analysis of Gram’s method and PAS for the identification of Candida spp. samples from the oral mucosa

    Directory of Open Access Journals (Sweden)

    Cátia Martins Leite Padilha

    2014-10-01

    Full Text Available Introduction: Candida species are part of the normal microbiota of healthy subjects, living as commensals. However, they can become pathogenic when changes in the mechanisms of host defense or disruption of anatomic barriers occur. Candidiasis is the most common fungal infection in the oral cavity, mainly caused by Candida albicans. The diagnosis is based on symptoms and clinical aspects, in association with laboratory methods. Objective: To evaluate the sensitivity and specificity of Gram’s method for Candida spp. identification in scrapes from the buccal mucosa and evaluate the degree of concordance between clinical and cytological methods in the diagnosis of oral candidiasis. Material and methods: A blind study was performed in 170 smears from patients of Hospital Universitário Antônio Pedro of Universidade Federal Fluminense (HUAP/UFF, stained by Gram (n = 57, periodic acid-Schiff (PAS (n = 57 and Papanicolaou (Pap (n = 57 methods. Results: The comparative analysis of the methods demonstrated a higher prevalence of Candida spp. (12% in PAS than in Gram staining, without statistic significance. The cytology method was positive in 93% of the clinical diagnosis of candidiasis. Conclusion: Gram was an adequate method; however more intensive professional training would be necessary to identify the fungus morphological structures. Although Pap test is the most common method of routine cytopathologic examination, for candidiasis diagnosis PAS staining is also recommended. Thus, it is suggested that candidiasis diagnosis should be accomplished by clinical evaluation in association with cytopathological analysis based on the identification of hyphae and/or pseudohyphae.

  14. How Do States Integrate Performance Assessment in Their Systems of Assessment?

    Science.gov (United States)

    Stosich, Elizabeth Leisy; Snyder, Jon; Wilczak, Katie

    2018-01-01

    This paper reviews state strategies for incorporating performance assessment in policy and practice. Specifically, the paper reviews the use of performance assessment in 12 states in the Innovation Lab Network, a group committed to developing systems of assessment that provide meaningful measures of college and career readiness. This review…

  15. Performance assessment for low-level radioactive waste disposal

    International Nuclear Information System (INIS)

    Cook, J.R.; Hsu, R.H.; Wilhite, E.L.; Yu, A.D.

    1996-01-01

    In October 1994 the Savannah River Site became the first US DOE complex to use concrete vaults to dispose of low-level radioactive solid waste and better prevent soil and groundwater contamination. This article describes the design and gives a performance assessment of the vaults. Topics include the following: Performance objectives; scope; the performance assessment process-assemble a multidisciplinary working group; collect available data; define credible pathways/scenarios; develop conceptual models; conduct screening and detailed model calculations; assess sensitivity/uncertainty; integrate and interpret results; report. 9 figs., 3 tabs

  16. Performance assessment review for DOE LLW disposal facilities

    International Nuclear Information System (INIS)

    Wilhite, Elmer L.

    1992-01-01

    The United States Department of Energy (US DOE) disposes of low-level radioactive waste in near-surface disposal facilities. Safety of the disposal operations is evaluated for operational safety as well as long-term safety. Operational safety is evaluated based on the perceived level of hazard of the operation and may vary from a simple safety assessment to a safety analysis report. Long-term safety of all low-level waste disposal systems is evaluated through the conduct of a radiological performance assessment. The US DOE has established radiological performance objectives for disposal of low-level waste. They are to protect a member of the general public from receiving over 25 mrem/y, and an inadvertent intruder into the waste from receiving over 100 mrem/y continuous exposure or 500 mrem from a single exposure. For a disposal system to be acceptable, a performance assessment must be prepared which must be technically accurate and provide reasonable assurance that these performance objectives are met. Technical quality of the performance assessments is reviewed by a panel of experts. The panel of experts is used in two ways to assure the technical quality of performance assessment. A preliminary (generally 2 day) review by the panel is employed in the late stages of development to provide guidance on finalizing the performance assessment. The comments from this review are communicated to the personnel responsible for the performance assessment for consideration and incorporation. After finalizing the performance assessment, it is submitted for a formal review. The formal review is accomplished by a much more thorough analysis of the performance assessment over a multi-week time period. The panel then formally reports their recommendations to the US DOE waste management senior staff who make the final determination on acceptability of the performance assessment. A number of lessons have been learned from conducting several preliminary reviews of performance

  17. Assessment Training Effects on Student Assessment Skills and Task Performance in a Technology-Facilitated Peer Assessment

    Science.gov (United States)

    Liu, Xiongyi; Li, Lan

    2014-01-01

    This study examines the impact of an assessment training module on student assessment skills and task performance in a technology-facilitated peer assessment. Seventy-eight undergraduate students participated in the study. The participants completed an assessment training exercise, prior to engaging in peer-assessment activities. During the…

  18. Functional immunoglobulin E cross-reactivity between Pas n 1 of Bahia grass pollen and other group 1 grass pollen allergens.

    Science.gov (United States)

    Davies, J M; Dang, T D; Voskamp, A; Drew, A C; Biondo, M; Phung, M; Upham, J W; Rolland, J M; O'Hehir, R E

    2011-02-01

    Grass pollens are major triggers of allergic rhinitis and asthma, but the immunological relationships between pollen allergens of the subtropical Bahia grass, Paspalum notatum, and temperate grasses are unresolved. To assess serum IgE cross-reactivity between subtropical P. notatum and temperate Lolium perenne (Ryegrass) pollen allergens. Serum IgE reactivities of grass pollen-allergic patients with P. notatum, L. perenne and Cynodon dactylon (Bermuda grass) pollen extracts and their respective purified group 1 allergens, Pas n 1, Lol p 1 and Cyn d 1, were compared by immunoblotting, ELISA and basophil activation. In a cohort of 51 patients from a temperate region, a high frequency of IgE reactivity with each grass pollen was detected, but reactivity with L. perenne pollen was substantially greater than with P. notatum and C. dactylon pollen. Similarly, serum IgE reactivity with Lol p 1 was greater than with Pas n 1 or Cyn d 1. For seven of eight sera studied in detail, asymmetric serum IgE cross-reactivity was observed; L. perenne pollen inhibited IgE reactivity with P. notatum pollen but not the converse, and IgE reactivity with Pas n 1 was inhibited by Lol p 1 but IgE reactivity with Lol p 1 was not inhibited by Pas n 1 or Cyn d 1. Importantly, P. notatum pollen and Pas n 1 activated basophils in grass pollen-allergic patients from a temperate region, although stimulation was greater by pollen of L. perenne than P. notatum or C. dactylon, and by Lol p 1 than Pas n 1 or Cyn d 1. In contrast, a cohort of 47 patients from a subtropical region showed similar IgE reactivity with P. notatum and L. perenne pollen, and reciprocal cross-inhibition of IgE reactivity between L. perenne and P. notatum. Pollen allergens of the subtropical P. notatum, including Pas n 1, show clinically relevant IgE cross-reactivity with pollen allergens of L. perenne but also species-specific IgE reactivity. © 2011 Blackwell Publishing Ltd.

  19. [Teaching performance assessment in Public Health employing three different strategies].

    Science.gov (United States)

    Martínez-González, Adrián; Moreno-Altamirano, Laura; Ponce-Rosas, Efrén Raúl; Martínez-Franco, Adrián Israel; Urrutia-Aguilar, María Esther

    2011-01-01

    The educational system depends upon the quality and performance of their faculty and should therefore be process of continuous improvement. To assess the teaching performance of the Public Health professors, at the Faculty of Medicine, UNAM through three strategies. Justification study. The evaluation was conducted under a mediational model through three strategies: students' opinion assessment, self-assessment and students' academic achievement. We applied descriptive statistics, Student t test, ANOVA and Pearson correlation. Twenty professors were evaluated from the Public Health department, representing 57% of all them who teach the subject. The professor's performance was highly valued self-assessment compared with assessment of student opinion, was confirmed by statistical analysis the difference was significant. The difference amongst the three evaluation strategies became more evident between self-assessment and the scores obtained by students in their academic achievement. The integration of these three strategies offers a more complete view of the teacher's performance quality. Academic achievement appears to be a more objective strategy for teaching performance assessment than students' opinion and self-assessment.

  20. Hanford low-level tank waste interim performance assessment

    International Nuclear Information System (INIS)

    Mann, F.M.

    1997-01-01

    The Hanford Low-Level Tank Waste Interim Performance Assessment examines the long-term environmental and human health effects associated with the disposal of the low-level fraction of the Hanford single and double-shell tank waste in the Hanford Site 200 East Area. This report was prepared as a good management practice to provide needed information about the relationship between the disposal system design and performance early in the disposal system project cycle. The calculations in this performance assessment show that the disposal of the low-level fraction can meet environmental and health performance objectives

  1. Development of Integrated Assessment Technology of Risk and Performance

    International Nuclear Information System (INIS)

    Yang, Jun Eon; Kang, Dae Il; Kang, Hyun Gook

    2010-04-01

    The main idea and contents are summarized as below 1) Development of new risk/performance assessment system innovating old labor-intensive risk assessment structure - New consolidated risk assessment technology from various hazard(flood, fire, seismic in NPP) - BOP model development for performance monitoring - Consolidated risk/performance management system for consistency and efficiency of NPP 2) Resolution technology for pending issues in PSA - Base technology for PSA of digital I and C system - Base technology for seismic PSA reflecting domestic seismic characteristics and aging effect - Uncertainty reduction technology for level 2 PSA and best estimation of containment failure frequency 3) Next generation risk/performance assessment technology - Human-induced error reduction technology for efficient operation of a NPP

  2. performance assessment of substation site earthing using fluke ...

    African Journals Online (AJOL)

    2013-03-01

    Mar 1, 2013 ... Earthing is the fundamental requirement for protection in all electrical ... for the performance assessment of this instrument as compare to the conventional system. ... tem and the reference earth at a given operating fre- quency ...

  3. Organic migration forms of radionuclides and performance assessment

    International Nuclear Information System (INIS)

    Xu Gouqing

    2010-01-01

    Much attention is paid to inorganic migration forms of radionuclides in groundwater during performance assessment before and organic migration forms, are seldom noted. Therefore some question may come into confidence level in performance assessment. This paper mainly discusses the distribution of organic substances in groundwater and their potential effect on performance assessment. The results obtained in recent years show that clay rocks are generally impermeable to water, but in some cases the interstitial water may be observed in them and the concentration of DOC, HA and FA is rather higher than that in granitic groundwater. The concentration of DOC is relatively low in granitic groundwater, but up to now the effect of organic migration forms of radionuclides in granitic groundwater on performance assessment is not finally determined, it is necessary to make further investigations. (authors)

  4. economic assessment of the performance of private sector ...

    African Journals Online (AJOL)

    Admin

    Economic and Extension, Delta State University, Asaba Campus, Nigeria ... This paper critically attempts to assess the performance of the private sector ... economy would depend to a large extent on the quantity ..... New York, USA: McGraw.

  5. An assessment of organisational values, culture and performance in ...

    African Journals Online (AJOL)

    An assessment of organisational values, culture and performance in Cape Town's ... confusion, control, manipulation, blame, power, results orientation, hierarchy, ... Conclusion: The organisational culture of the Metro District Health Services is ...

  6. ASSESSING INDIVIDUAL PERFORMANCE ON INFORMATION TECHNOLOGY ADOPTION: A NEW MODEL

    OpenAIRE

    Diah Hari Suryaningrum

    2012-01-01

    This paper aims to propose a new model in assessing individual performance on information technology adoption. The new model to assess individual performance was derived from two different theories: decomposed theory of planned behavior and task-technology fit theory. Although many researchers have tried to expand these theories, some of their efforts might lack of theoretical assumptions. To overcome this problem and enhance the coherence of the integration, I used a theory from social scien...

  7. Performance assessment for underground radioactive waste disposal systems

    International Nuclear Information System (INIS)

    1985-01-01

    A waste disposal system comprises a number of subsystems and components. The performance of most systems can be demonstrated only indirectly because of the long period that would be required to test them. This report gives special attention to performance assessment of subsystems within the total waste disposal system, and is an extension of an IAEA report on Safety Assessment for the Underground Disposal of Radioactive Wastes

  8. Conceptual framework for performance assessment: competency, competence and performance in the context of assessments in healthcare--deciphering the terminology.

    Science.gov (United States)

    Khan, Kamran; Ramachandran, Sankaranarayanan

    2012-01-01

    The definitions of performance, competence and competency are not very clear in the literature. The assessment of performance and the selection of tools for this purpose depend upon a deep understanding of each of the above terms and the factors influencing performance. In this article, we distinguish between competence and competency and explain the relationship of competence and performance in the light of the Dreyfus model of skills acquisition. We briefly critique the application of the principles described by Miller to the modern assessment tools and distinguish between assessment of actual performance in workplace settings and the observed performance, demonstrated by the candidates in the workplace or simulated settings. We describe a modification of the Dreyfus model applicable to assessments in healthcare and propose a new model for the assessment of performance and performance rating scale (PRS) based on this model. We propose that the use of adapted versions of this PRS will result in benchmarking of performance and allowing the candidates to track their progression of skills in various areas of clinical practice.

  9. Performance and Cognitive Assessment in 3-D Modeling

    Science.gov (United States)

    Fahrer, Nolan E.; Ernst, Jeremy V.; Branoff, Theodore J.; Clark, Aaron C.

    2011-01-01

    The purpose of this study was to investigate identifiable differences between performance and cognitive assessment scores in a 3-D modeling unit of an engineering drafting course curriculum. The study aimed to provide further investigation of the need of skill-based assessments in engineering/technical graphics courses to potentially increase…

  10. Visual art teachers and performance assessment methods in ...

    African Journals Online (AJOL)

    This paper examines the competencies of visual arts teachers in using performance assessment methods, and to ascertain the extent to which the knowledge, skills and experiences of teachers affect their competence in using assessment strategies in their classroom. The study employs a qualitative research design; ...

  11. Data on Student Performance Under Different Forms of Assessment

    Science.gov (United States)

    King, Russell

    1976-01-01

    Recognition of various abilities and skills in university degree work, and the development of an appropriate range of assessment modes to test these abilities, presupposes that students will perform differently under the various forms of assessment. The limited data available to test this supposition are reviewed and analysis of one geography…

  12. Performance Assessment of the Masses in 30 Seconds or Less

    Science.gov (United States)

    Dunbar, Laura

    2012-01-01

    Performance assessment does not have to be a time-consuming ordeal; it is a great way to assess our students' skills. It is essential to create a rubric that is simple, quick, and objective. This article discusses the process of creating a rubric as well as showing a rubric used by the author in her general music classroom for several years.…

  13. Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 5, Uncertainty and sensitivity analyses of gas and brine migration for undisturbed performance

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    Before disposing of transuranic radioactive waste in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments (PAs) of the WIPP for the DOE to provide interim guidance while preparing for a final compliance evaluation. This volume of the 1992 PA contains results of uncertainty and sensitivity analyses with respect to migration of gas and brine from the undisturbed repository. Additional information about the 1992 PA is provided in other volumes. Volume 1 contains an overview of WIPP PA and results of a preliminary comparison with 40 CFR 191, Subpart B. Volume 2 describes the technical basis for the performance assessment, including descriptions of the linked computational models used in the Monte Carlo analyses. Volume 3 contains the reference data base and values for input parameters used in consequence and probability modeling. Volume 4 contains uncertainty and sensitivity analyses with respect to the EPA`s Environmental Standards for the Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). Finally, guidance derived from the entire 1992 PA is presented in Volume 6. Results of the 1992 uncertainty and sensitivity analyses indicate that, conditional on the modeling assumptions and the assigned parameter-value distributions, the most important parameters for which uncertainty has the potential to affect gas and brine migration from the undisturbed repository are: initial liquid saturation in the waste, anhydrite permeability, biodegradation-reaction stoichiometry, gas-generation rates for both corrosion and biodegradation under inundated conditions, and the permeability of the long-term shaft seal.

  14. Self- and peer-assessments of ambulance drivers' driving performance

    Directory of Open Access Journals (Sweden)

    Anna Sundström

    2012-07-01

    Full Text Available The aim of the present study was to develop and examine the quality of the Ambulance Driver Self-assessment Questionnaire (ADSQ and the Ambulance Driver Peer-assessment Questionnaire (ADPQ measuring aspects of, driving performance, driving style and driving competence. In addition the ADSQ measures self-reflection and safety-attitudes. The aim of the study was also to examine ambulance drivers' self- and peer-assessments as well as to examine the accuracy of self-assessments by comparing self-assessed and peer-assessed driving performance, driving style and competence. 76 ambulance drivers employed at two ambulance stations in northern Sweden completed ADSQ and ADPQ. Item analyses were conducted to examine the psychometric properties of the items, and based on the results some revisions were made to improve the questionnaires. The revised questionnaires were functioning rather well, although some subscale demonstrated low internal consistency. Subscale inter-correlations provided support for construct validity. Self- and peer-assessments indicated safe driving performance and good driver competence, which is positive from a traffic safety perspective. A comparison of mean self- and peer-assessment ratings, controlling for age, gender and driving experience showed no significant differences, except for the subscale overtaking. This indicates that ambulance drivers' self-assessments are realistic in most areas.

  15. Performance Objective for Tank Farm Closure Risk Assessments

    International Nuclear Information System (INIS)

    MANN, F.M.; KNEPP, A.J.; BADDEN, J.

    2003-01-01

    To be meaningful, results from a numeric risk assessment of the consequences of an action must be compared against the standards for such an action. That is, before one disposes of waste or closes a facility with waste, one must show that the disposal or closure action protects the public health and safety and the environment. These standards are called performance objectives. Regulations requiring performing performance assessments, (whether federal ones like the Department of Energy [DOE] Order 435.1, Radioactive Waste Management and its implementing guides or Washington State ones like the regulations implementing the Washington Administrative Code [WAC] 173-340 ''Model Toxics Control Act - Cleanup''), usually require that the determination of performance objectives be one of the first steps performed. These performance objectives not only set comparison level for the numeric results, but also define the media, pathways, exposure scenarios (receptors), spatial locations, and times that the performance assessment must consider. Thus, a performance objective consists of a compliance level, place(s) of compliance, and time(s) of compliance. Performance objectives are not the levels that a regulatory agency will enforce in a permit or authorization. Those levels, often called enforcement levels, will be set in the permit or authorization. Rather, performance objectives are those levels against which the results of the numeric simulation will be compared to judge the success of the proposed cleanup or disposal actions. Additional comparison levels may be requested for information purposes, but are not officially part of the decision on the adequacy of the proposed action. To emphasize that the performance objectives discussed in this document are not regulatory performance objectives, the three components of the performance objective will be renamed in this document as assessment standard, point(s) of assessment, and time(s) of assessment. However, whenever

  16. Subjective and objective performance assessment : Performance pay at Trelleborg Forsheda AB

    OpenAIRE

    Luotonen, David; Hasselström, Markus

    2009-01-01

      The purpose of this thesis is to understand the opinions and potential effects of objective and subjective assessments of performance as a basis for performance pay for blue-collar workers. The study takes a qualitative approach to find out how and why four companies - Trelleborg Forsheda, Finnveden Powertrain, Isaberg Rapid and Parker Hannifin- work with salaries, incentive system and performance assessment the way they do. The concept of individual salary is central in this thesis, and in...

  17. 10 CFR 63.114 - Requirements for performance assessment.

    Science.gov (United States)

    2010-01-01

    ... processes of engineered barriers in the performance assessment, including those processes that would adversely affect the performance of natural barriers. Degradation, deterioration, or alteration processes of... surrounding region to the extent necessary, and information on the design of the engineered barrier system...

  18. The Concept of Performance Levels in Criterion-Referenced Assessment.

    Science.gov (United States)

    Hewitson, Mal

    The concept of performance levels in criterion-referenced assessment is explored by applying the idea to different types of tests commonly used in schools, mastery tests (including diagnostic tests) and achievement tests. In mastery tests, a threshold performance standard must be established for each criterion. Attainment of this threshold…

  19. Epitaxial nanowire formation in metamorphic GaAs/GaPAs short-period superlattices

    Science.gov (United States)

    Zheng, Nan; Ahrenkiel, S. Phillip

    2017-07-01

    Metamorphic growth presents routes to novel nanomaterials with unique properties that may be suitable for a range of applications. We discuss self-assembled, epitaxial nanowires formed during metalorganic chemical vapor deposition of metamorphic GaAs/GaPAs short-period superlattices. The heterostructures incorporate strain-engineered GaPAs compositional grades on 6°-B miscut GaAs substrates. Lateral diffusion within the SPS into vertically aligned, three-dimensional columns results in nanowires extending along A directions with a lateral period of 70-90 nm. The microstructure is probed by transmission electron microscopy to confirm the presence of coherent GaAs nanowires within GaPAs barriers. The compositional profile is inferred from analysis of {200} dark-field image contrast and lattice images.

  20. The assessment and treatment of performance anxiety in musicians.

    Science.gov (United States)

    Clark, D B; Agras, W S

    1991-05-01

    Performance anxiety in musicians may be severe enough to require intervention but has been the subject of relatively little clinical research. The authors' objectives were to describe the results of a comprehensive clinical and laboratory assessment and to perform a double-blind, placebo-controlled study comparing buspirone, cognitive-behavior therapy, and the combination of these treatments for performance anxiety. Ninety-four subjects were recruited by mass media announcements and were seen in a university-based outpatient psychiatric clinic. Assessments were 1) questionnaires for all 94 subjects, 2) diagnostic interview of 50 subjects, and 3) laboratory performance of 34 subjects. Treatment conditions were 1) 6 weeks of buspirone, 2) 6 weeks of placebo, 3) a five-session, group cognitive-behavior therapy program with buspirone, or 4) the cognitive-behavior therapy program with placebo. Treatment outcome measures included subjective anxiety ratings and heart rate measures during a laboratory performance, a questionnaire measure of performance confidence, and a blind rating of musical performance quality. All subjects fulfilled criteria for DSM-III-R social phobia. Of the 15 full-time professional musicians, ten had tried propranolol and three had stopped performing. Most of the subjects had substantial anxiety and heart rate increases during laboratory speech and musical performances. Cognitive-behavior therapy resulted in statistically significant reductions in subjective anxiety, improved quality of musical performance, and improved performance confidence. Buspirone was not an effective treatment. Cognitive-behavior therapy is a viable treatment approach for performance anxiety in musicians.

  1. ANALYSING PERFORMANCE ASSESSMENT IN PUBLIC SERVICES: HOW USEFUL IS THE CONCEPT OF A PERFORMANCE REGIME?

    Science.gov (United States)

    Martin, Steve; Nutley, Sandra; Downe, James; Grace, Clive

    2016-03-01

    Approaches to performance assessment have been described as 'performance regimes', but there has been little analysis of what is meant by this concept and whether it has any real value. We draw on four perspectives on regimes - 'institutions and instruments', 'risk regulation regimes', 'internal logics and effects' and 'analytics of government' - to explore how the concept of a multi-dimensional regime can be applied to performance assessment in public services. We conclude that the concept is valuable. It helps to frame comparative and longitudinal analyses of approaches to performance assessment and draws attention to the ways in which public service performance regimes operate at different levels, how they change over time and what drives their development. Areas for future research include analysis of the impacts of performance regimes and interactions between their visible features (such as inspections, performance indicators and star ratings) and the veiled rationalities which underpin them.

  2. Process, Voltage and Temperature Compensation Technique for Cascode Modulated PAs

    DEFF Research Database (Denmark)

    Sira, Daniel; Larsen, Torben

    2013-01-01

    , that represents a transistor level model (empirical model) of the cascode modulated PA, is utilized in a PA analog predistorter. The analog predistorter linearizes and compensates for PVT variation of the cascode modulated PA. The empirical model is placed in the negative feedback of an operational...... transconductance amplifier. The predistorted varying envelope signal is applied to the cascode gate of the PA. It is shown that the proposed PVT compensation technique significantly reduces the PVT spread of the PA linearity indicators and improves the PA linearity. Simulations were performed in a 0.13 μm CMOS...

  3. Performance assessment techniques for groundwater recovery and treatment systems

    Energy Technology Data Exchange (ETDEWEB)

    Kirkpatrick, G.L. [Environmental Resources Management, Inc., Exton, PA (United States)

    1993-03-01

    Groundwater recovery and treatment (pump and treat systems) continue to be the most commonly selected remedial technology for groundwater restoration and protection programs at hazardous waste sites and RCRA facilities nationwide. Implementing a typical groundwater recovery and treatment system includes the initial assessment of groundwater quality, characterizing aquifer hydrodynamics, recovery system design, system installation, testing, permitting, and operation and maintenance. This paper focuses on methods used to assess the long-term efficiency of a pump and treat system. Regulatory agencies and industry alike are sensitive to the need for accurate assessment of the performance and success of groundwater recovery systems for contaminant plume abatement and aquifer restoration. Several assessment methods are available to measure the long-term performance of a groundwater recovery system. This paper presents six assessment techniques: degree of compliance with regulatory agency agreement (Consent Order of Record of Decision), hydraulic demonstration of system performance, contaminant mass recovery calculation, system design and performance comparison, statistical evaluation of groundwater quality and preferably, integration of the assessment methods. Applying specific recovery system assessment methods depends upon the type, amount, and quality of data available. Use of an integrated approach is encouraged to evaluate the success of a groundwater recovery and treatment system. The methods presented in this paper are for engineers and corporate management to use when discussing the effectiveness of groundwater remediation systems with their environmental consultant. In addition, an independent (third party) system evaluation is recommended to be sure that a recovery system operates efficiently and with minimum expense.

  4. Machine performance assessment and enhancement for a hexapod machine

    Energy Technology Data Exchange (ETDEWEB)

    Mou, J.I. [Arizona State Univ., Tempe, AZ (United States); King, C. [Sandia National Labs., Livermore, CA (United States). Integrated Manufacturing Systems Center

    1998-03-19

    The focus of this study is to develop a sensor fused process modeling and control methodology to model, assess, and then enhance the performance of a hexapod machine for precision product realization. Deterministic modeling technique was used to derive models for machine performance assessment and enhancement. Sensor fusion methodology was adopted to identify the parameters of the derived models. Empirical models and computational algorithms were also derived and implemented to model, assess, and then enhance the machine performance. The developed sensor fusion algorithms can be implemented on a PC-based open architecture controller to receive information from various sensors, assess the status of the process, determine the proper action, and deliver the command to actuators for task execution. This will enhance a hexapod machine`s capability to produce workpieces within the imposed dimensional tolerances.

  5. Digital radiography using amorphous selenium: photoconductively activated switch (PAS) readout system.

    Science.gov (United States)

    Reznik, Nikita; Komljenovic, Philip T; Germann, Stephen; Rowlands, John A

    2008-03-01

    A new amorphous selenium (a-Se) digital radiography detector is introduced. The proposed detector generates a charge image in the a-Se layer in a conventional manner, which is stored on electrode pixels at the surface of the a-Se layer. A novel method, called photoconductively activated switch (PAS), is used to read out the latent x-ray charge image. The PAS readout method uses lateral photoconduction at the a-Se surface which is a revolutionary modification of the bulk photoinduced discharge (PID) methods. The PAS method addresses and eliminates the fundamental weaknesses of the PID methods--long readout times and high readout noise--while maintaining the structural simplicity and high resolution for which PID optical readout systems are noted. The photoconduction properties of the a-Se surface were investigated and the geometrical design for the electrode pixels for a PAS radiography system was determined. This design was implemented in a single pixel PAS evaluation system. The results show that the PAS x-ray induced output charge signal was reproducible and depended linearly on the x-ray exposure in the diagnostic exposure range. Furthermore, the readout was reasonably rapid (10 ms for pixel discharge). The proposed detector allows readout of half a pixel row at a time (odd pixels followed by even pixels), thus permitting the readout of a complete image in 30 s for a 40 cm x 40 cm detector with the potential of reducing that time by using greater readout light intensity. This demonstrates that a-Se based x-ray detectors using photoconductively activated switches could form a basis for a practical integrated digital radiography system.

  6. Incorrect Weighting of Absolute Performance in Self-Assessment

    Science.gov (United States)

    Jeffrey, Scott A.; Cozzarin, Brian

    Students spend much of their life in an attempt to assess their aptitude for numerous tasks. For example, they expend a great deal of effort to determine their academic standing given a distribution of grades. This research finds that students use their absolute performance, or percentage correct as a yardstick for their self-assessment, even when relative standing is much more informative. An experiment shows that this reliance on absolute performance for self-evaluation causes a misallocation of time and financial resources. Reasons for this inappropriate responsiveness to absolute performance are explored.

  7. Treatment of uncertainty in low-level waste performance assessment

    International Nuclear Information System (INIS)

    Kozak, M.W.; Olague, N.E.; Gallegos, D.P.; Rao, R.R.

    1991-01-01

    Uncertainties arise from a number of different sources in low-level waste performance assessment. In this paper the types of uncertainty are reviewed, and existing methods for quantifying and reducing each type of uncertainty are discussed. These approaches are examined in the context of the current low-level radioactive waste regulatory performance objectives, which are deterministic. The types of uncertainty discussed in this paper are model uncertainty, uncertainty about future conditions, and parameter uncertainty. The advantages and disadvantages of available methods for addressing uncertainty in low-level waste performance assessment are presented. 25 refs

  8. Performance Assessment for Pump-and-Treat Closure or Transition

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnson, Christian D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Becker, Dave J. [U.S. Army Corps of Engineers Environmental and Munitions Center of Expertise, Huntsville, AL (United States); Lee, Michelle H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Nimmons, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-29

    A structured performance assessment approach is useful to evaluate pump-and-treat (P&T) groundwater remediation, which has been applied at numerous sites. Consistent with the U.S. Environmental Protection Agency’s Groundwater Road Map, performance assessment during remedy implementation may be needed, and should consider remedy optimization, transition to alternative remedies, or remedy closure. In addition, a recent National Research Council study examined groundwater remediation at complex contaminated sites and concluded that it may be beneficial to evaluate remedy performance and the potential need for transition to alternative approaches at these sites. The intent of this document is to provide a structured approach for assessing P&T performance to support a decision to optimize, transition, or close a P&T remedy. The process presented in this document for gathering information and performing evaluations to support P&T remedy decisions includes use of decision elements to distinguish between potential outcomes of a remedy decision. Case studies are used to augment descriptions of decision elements and to illustrate each type of outcome identified in the performance assessment approach. The document provides references to resources for tools and other guidance relevant to conducting the P&T assessment.

  9. Performance Analysis of the Capability Assessment Tool for Sustainable Manufacturing

    Directory of Open Access Journals (Sweden)

    Enda Crossin

    2013-08-01

    Full Text Available This paper explores the performance of a novel capability assessment tool, developed to identify capability gaps and associated training and development requirements across the supply chain for environmentally-sustainable manufacturing. The tool was developed to assess 170 capabilities that have been clustered with respect to key areas of concern such as managing energy, water, material resources, carbon emissions and waste as well as environmental management practices for sustainability. Two independent expert teams used the tool to assess a sample group of five first and second tier sports apparel and footwear suppliers within the supply chain of a global sporting goods manufacturer in Asia. The paper addresses the reliability and robustness of the developed assessment method by formulating the expected links between the assessment results. The management practices of the participating suppliers were shown to be closely connected to their performance in managing their resources and emissions. The companies’ initiatives in implementing energy efficiency measures were found to be generally related to their performance in carbon emissions management. The suppliers were also asked to undertake a self-assessment by using a short questionnaire. The large gap between the comprehensive assessment and these in-house self-assessments revealed the suppliers’ misconceptions about their capabilities.

  10. Assessing performance and validating finite element simulations using probabilistic knowledge

    Energy Technology Data Exchange (ETDEWEB)

    Dolin, Ronald M.; Rodriguez, E. A. (Edward A.)

    2002-01-01

    Two probabilistic approaches for assessing performance are presented. The first approach assesses probability of failure by simultaneously modeling all likely events. The probability each event causes failure along with the event's likelihood of occurrence contribute to the overall probability of failure. The second assessment method is based on stochastic sampling using an influence diagram. Latin-hypercube sampling is used to stochastically assess events. The overall probability of failure is taken as the maximum probability of failure of all the events. The Likelihood of Occurrence simulation suggests failure does not occur while the Stochastic Sampling approach predicts failure. The Likelihood of Occurrence results are used to validate finite element predictions.

  11. Self-assessed performance improves statistical fusion of image labels

    International Nuclear Information System (INIS)

    Bryan, Frederick W.; Xu, Zhoubing; Asman, Andrew J.; Allen, Wade M.; Reich, Daniel S.; Landman, Bennett A.

    2014-01-01

    Purpose: Expert manual labeling is the gold standard for image segmentation, but this process is difficult, time-consuming, and prone to inter-individual differences. While fully automated methods have successfully targeted many anatomies, automated methods have not yet been developed for numerous essential structures (e.g., the internal structure of the spinal cord as seen on magnetic resonance imaging). Collaborative labeling is a new paradigm that offers a robust alternative that may realize both the throughput of automation and the guidance of experts. Yet, distributing manual labeling expertise across individuals and sites introduces potential human factors concerns (e.g., training, software usability) and statistical considerations (e.g., fusion of information, assessment of confidence, bias) that must be further explored. During the labeling process, it is simple to ask raters to self-assess the confidence of their labels, but this is rarely done and has not been previously quantitatively studied. Herein, the authors explore the utility of self-assessment in relation to automated assessment of rater performance in the context of statistical fusion. Methods: The authors conducted a study of 66 volumes manually labeled by 75 minimally trained human raters recruited from the university undergraduate population. Raters were given 15 min of training during which they were shown examples of correct segmentation, and the online segmentation tool was demonstrated. The volumes were labeled 2D slice-wise, and the slices were unordered. A self-assessed quality metric was produced by raters for each slice by marking a confidence bar superimposed on the slice. Volumes produced by both voting and statistical fusion algorithms were compared against a set of expert segmentations of the same volumes. Results: Labels for 8825 distinct slices were obtained. Simple majority voting resulted in statistically poorer performance than voting weighted by self-assessed performance

  12. Self-assessed performance improves statistical fusion of image labels

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Frederick W., E-mail: frederick.w.bryan@vanderbilt.edu; Xu, Zhoubing; Asman, Andrew J.; Allen, Wade M. [Electrical Engineering, Vanderbilt University, Nashville, Tennessee 37235 (United States); Reich, Daniel S. [Translational Neuroradiology Unit, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland 20892 (United States); Landman, Bennett A. [Electrical Engineering, Vanderbilt University, Nashville, Tennessee 37235 (United States); Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37235 (United States); and Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee 37235 (United States)

    2014-03-15

    Purpose: Expert manual labeling is the gold standard for image segmentation, but this process is difficult, time-consuming, and prone to inter-individual differences. While fully automated methods have successfully targeted many anatomies, automated methods have not yet been developed for numerous essential structures (e.g., the internal structure of the spinal cord as seen on magnetic resonance imaging). Collaborative labeling is a new paradigm that offers a robust alternative that may realize both the throughput of automation and the guidance of experts. Yet, distributing manual labeling expertise across individuals and sites introduces potential human factors concerns (e.g., training, software usability) and statistical considerations (e.g., fusion of information, assessment of confidence, bias) that must be further explored. During the labeling process, it is simple to ask raters to self-assess the confidence of their labels, but this is rarely done and has not been previously quantitatively studied. Herein, the authors explore the utility of self-assessment in relation to automated assessment of rater performance in the context of statistical fusion. Methods: The authors conducted a study of 66 volumes manually labeled by 75 minimally trained human raters recruited from the university undergraduate population. Raters were given 15 min of training during which they were shown examples of correct segmentation, and the online segmentation tool was demonstrated. The volumes were labeled 2D slice-wise, and the slices were unordered. A self-assessed quality metric was produced by raters for each slice by marking a confidence bar superimposed on the slice. Volumes produced by both voting and statistical fusion algorithms were compared against a set of expert segmentations of the same volumes. Results: Labels for 8825 distinct slices were obtained. Simple majority voting resulted in statistically poorer performance than voting weighted by self-assessed performance

  13. Correlating the content and context of PAS 55 with the ISO 55000 series

    Directory of Open Access Journals (Sweden)

    Van den Honert, A. F.

    2013-08-01

    Full Text Available The ISO 55000 series is soon to supersede PAS 55 as the most recognised international standard for asset management. A correlation of the content and context of PAS 55 with the ISO 55000 series is required to assist organisations with the transition. After analysis of the structures, similarities, differences, and omissions of the two standards, a map was created to correlate the summarised content and context. The map established that, although both sets of standards have a similar structural framework, the ISO 55000 series is a more comprehensive and detailed standard, creating a clearer way to implement an asset management system within an organisation.

  14. Assessment of Student Music Performances Using Deep Neural Networks

    Directory of Open Access Journals (Sweden)

    Kumar Ashis Pati

    2018-03-01

    Full Text Available Music performance assessment is a highly subjective task often relying on experts to gauge both the technical and aesthetic aspects of the performance from the audio signal. This article explores the task of building computational models for music performance assessment, i.e., analyzing an audio recording of a performance and rating it along several criteria such as musicality, note accuracy, etc. Much of the earlier work in this area has been centered around using hand-crafted features intended to capture relevant aspects of a performance. However, such features are based on our limited understanding of music perception and may not be optimal. In this article, we propose using Deep Neural Networks (DNNs for the task and compare their performance against a baseline model using standard and hand-crafted features. We show that, using input representations at different levels of abstraction, DNNs can outperform the baseline models across all assessment criteria. In addition, we use model analysis techniques to further explain the model predictions in an attempt to gain useful insights into the assessment process. The results demonstrate the potential of using supervised feature learning techniques to better characterize music performances.

  15. Geochemical Data Package for the 2005 Hanford Integrated Disposal Facility Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Krupka, Kenneth M.; Serne, R JEFFREY.; Kaplan, D I.

    2004-09-30

    CH2M HILL Hanford Group, Inc. (CH2M HILL) is designing and assessing the performance of an integrated disposal facility (IDF) to receive low-level waste (LLW), mixed low-level waste (MLLW), immobilized low-activity waste (ILAW), and failed or decommissioned melters. The CH2M HILL project to assess the performance of this disposal facility is the Hanford IDF Performance Assessment (PA) activity. The goal of the Hanford IDF PA activity is to provide a reasonable expectation that the disposal of the waste is protective of the general public, groundwater resources, air resources, surface-water resources, and inadvertent intruders. Achieving this goal will require prediction of contaminant migration from the facilities. This migration is expected to occur primarily via the movement of water through the facilities, and the consequent transport of dissolved contaminants in the vadose zone to groundwater where contaminants may be re-introduced to receptors via drinking water wells or mixing in the Columbia River. Pacific Northwest National Laboratory (PNNL) assists CH2M HILL in their performance assessment activities. One of the PNNL tasks is to provide estimates of the geochemical properties of the materials comprising the IDF, the disturbed region around the facility, and the physically undisturbed sediments below the facility (including the vadose zone sediments and the aquifer sediments in the upper unconfined aquifer). The geochemical properties are expressed as parameters that quantify the adsorption of contaminants and the solubility constraints that might apply for those contaminants that may exceed solubility constraints. The common parameters used to quantify adsorption and solubility are the distribution coefficient (Kd) and the thermodynamic solubility product (Ksp), respectively. In this data package, we approximate the solubility of contaminants using a more simplified construct, called the solution concentration limit, a constant value. The Kd values and

  16. DRSPALL: Impact of the Modification of the Numerical Spallings Model on Waste Isolation Pilot Plant Performance Assessment.

    Energy Technology Data Exchange (ETDEWEB)

    Kicker, Dwayne Curtis [Stoller Newport News Nuclear, Inc., Carlsbad, NM (United States); Herrick, Courtney G. [Sandia National Lab. (SNL-NM), Carlsbad, NM (United States); Zeitler, Todd [Sandia National Lab. (SNL-NM), Carlsbad, NM (United States); Malama, Bwalya [Sandia National Lab. (SNL-NM), Carlsbad, NM (United States); Rudeen, David Keith [GRAM Inc., Albuquerque, NM (United States); Gilkey, Amy P. [GRAM Inc., Albuquerque, NM (United States)

    2016-01-01

    The numerical code DRSPALL (from direct release spallings) is written to calculate the volume of Waste Isolation Pilot Plant (WIPP) solid waste subject to material failure and transport to the surface as a result of a hypothetical future inadvertent drilling intrusion. An error in the implementation of the DRSPALL finite difference equations was discovered as documented in Software Problem Report (SPR) 13-001. The modifications to DRSPALL to correct the finite difference equations are detailed, and verification and validation testing has been completed for the modified DRSPALL code. The complementary cumulative distribution function (CCDF) of spallings releases obtained using the modified DRSPALL is higher compared to that found in previous WIPP performance assessment (PA) calculations. Compared to previous PAs, there was an increase in the number of vectors that result in a nonzero spallings volume, which generally translates to an increase in spallings releases. The overall mean CCDFs for total releases using the modified DRSPALL are virtually unchanged, thus the modification to DRSPALL did not impact WIPP PA calculation results.

  17. Performance Standards': Utility for Different Uses of Assessments

    Directory of Open Access Journals (Sweden)

    Robert L. Linn

    2003-09-01

    Full Text Available Performance standards are arguably one of the most controversial topics in educational measurement. There are uses of assessments such as licensure and certification where performance standards are essential. There are many other uses, however, where performance standards have been mandated or become the preferred method of reporting assessment results where the standards are not essential to the use. Distinctions between essential and nonessential uses of performance standards are discussed. It is argued that the insistence on reporting in terms of performance standards in situations where they are not essential has been more harmful than helpful. Variability in the definitions of proficient academic achievement by states for purposes of the No Child Left Behind Act of 2001 is discussed and it is argued that the variability is so great that characterizing achievement is meaningless. Illustrations of the great uncertainty in standards are provided.

  18. Workplace-based assessment: raters' performance theories and constructs.

    Science.gov (United States)

    Govaerts, M J B; Van de Wiel, M W J; Schuwirth, L W T; Van der Vleuten, C P M; Muijtjens, A M M

    2013-08-01

    Weaknesses in the nature of rater judgments are generally considered to compromise the utility of workplace-based assessment (WBA). In order to gain insight into the underpinnings of rater behaviours, we investigated how raters form impressions of and make judgments on trainee performance. Using theoretical frameworks of social cognition and person perception, we explored raters' implicit performance theories, use of task-specific performance schemas and the formation of person schemas during WBA. We used think-aloud procedures and verbal protocol analysis to investigate schema-based processing by experienced (N = 18) and inexperienced (N = 16) raters (supervisor-raters in general practice residency training). Qualitative data analysis was used to explore schema content and usage. We quantitatively assessed rater idiosyncrasy in the use of performance schemas and we investigated effects of rater expertise on the use of (task-specific) performance schemas. Raters used different schemas in judging trainee performance. We developed a normative performance theory comprising seventeen inter-related performance dimensions. Levels of rater idiosyncrasy were substantial and unrelated to rater expertise. Experienced raters made significantly more use of task-specific performance schemas compared to inexperienced raters, suggesting more differentiated performance schemas in experienced raters. Most raters started to develop person schemas the moment they began to observe trainee performance. The findings further our understanding of processes underpinning judgment and decision making in WBA. Raters make and justify judgments based on personal theories and performance constructs. Raters' information processing seems to be affected by differences in rater expertise. The results of this study can help to improve rater training, the design of assessment instruments and decision making in WBA.

  19. White paper updating conclusions of 1998 ILAW performance assessment

    International Nuclear Information System (INIS)

    MANN, F.M.

    2000-01-01

    The purpose of this document is to provide a comparison of the estimated immobilized low-activity waste (LAW) disposal system performance against established performance objectives using the beat estimates for parameters and models to describe the system. The principal advances in knowledge since the last performance assessment (known as the 1998 ILAW PA [Mann 1998a]) have been in site specific information and data on the waste form performance for BNFL, Inc. relevant glass formulations. The white paper also estimates the maximum release rates for technetium and other key radionuclides and chemicals from the waste form. Finally, this white paper provides limited information on the impact of changes in waste form loading

  20. Effect of Engaging Trainees by Assessing Peer Performance

    DEFF Research Database (Denmark)

    Loumann Krogh, Charlotte; Ringsted, Charlotte; Kromann, Charles B

    2014-01-01

    during training. Outcome measures were in-training performance and performance, both of which were measured two weeks after the course. Trainees' performances were videotaped and assessed by two expert raters using a checklist that included a global rating. Trainees' satisfaction with the training...... was also evaluated. RESULTS: The intervention group obtained a significantly higher overall in-training performance score than the control group: mean checklist score 20.87 (SD 2.51) versus 19.14 (SD 2.65) P = 0.003 and mean global rating 3.25 SD (0.99) versus 2.95 (SD 1.09) P = 0.014. Postcourse...

  1. White paper updating conclusions of 1998 ILAW performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    MANN, F.M.

    2000-05-11

    The purpose of this document is to provide a comparison of the estimated immobilized low-activity waste (LAW) disposal system performance against established performance objectives using the beat estimates for parameters and models to describe the system. The principal advances in knowledge since the last performance assessment (known as the 1998 ILAW PA [Mann 1998a]) have been in site specific information and data on the waste form performance for BNFL, Inc. relevant glass formulations. The white paper also estimates the maximum release rates for technetium and other key radionuclides and chemicals from the waste form. Finally, this white paper provides limited information on the impact of changes in waste form loading.

  2. Current perspectives on performance assessment at the NRC

    International Nuclear Information System (INIS)

    Coplan, S.M.; Eisenberg, N.A.; Federline, M.V.; Randall, J.D.

    1992-01-01

    The Nuclear Regulatory Commission (NRC) staff is engaging in a number of activities involving performance assessment in order to support NRC's program in high-level waste management. Broad areas of activity include: (1) reactive work responding to products and activities of the Department of Energy (DOE), (2) proactive work, including development of an independent performance assessment capability, development of guidance for DOE, support for technical and programmatic integration, (3) a program of regulatory research, and (4) participation in a number of international activities. As the U.S. high-level waste program continues to mature, performance assessment is seen as playing a more prominent role in evaluating safety and focussing technical activities

  3. Assessment of Work Performance (AWP)--development of an instrument.

    Science.gov (United States)

    Sandqvist, Jan L; Törnquist, Kristina B; Henriksson, Chris M

    2006-01-01

    Adequate work assessments are a matter of importance both for individuals and society [5,29,31,38,40,46,52]. However, there is a lack of adequate and reliable instruments for use in work rehabilitation [14,15,20,21,31,44]. The purpose of this study was to develop and evaluate an observation instrument for assessing work performance, the AWP (Assessment of Work Performance). The purpose of the 14-item instrument is to assess the individual's observable working skills in three different areas: motor skills, process skills, and communication and interaction skills. This article describes the development and results of preliminary testing of the AWP. The testing indicates a satisfactory face validity and utility for the AWP and supports further research and testing of the instrument.

  4. SKI SITE-94. Deep Repository Performance Assessment Project. Summary

    International Nuclear Information System (INIS)

    1997-02-01

    The function of SITE-94 is to provide the Swedish Nuclear Power Inspectorate (SKI) with the capacity and supporting knowledge needed for reviewing the Swedish nuclear industry's R and D programs and for reviewing license applications, as stipulated in Swedish legislation. The report is structured as a Performance Assessment exercise needed for input to decisions regarding repository safety, but the SITE-94 is neither a safety assessment nor a model for future assessments to be undertaken by the prospective licensee. The specific project objectives of SITE-94 comprise site evaluation, performance assessment methodology, canister integrity and radionuclide release and transport calculations. The main report (SKI-R--96-36) gives a detailed description of the many inter-related studies undertaken as part of the research project, while the present report presents a condensed summary of the main report. 46 refs

  5. Increase in PAS-induced neuroplasticity after a treatment course of intranasal ketamine for depression. Report of three cases from a placebo-controlled trial.

    Science.gov (United States)

    Gálvez, Verònica; Nikolin, Stevan; Ho, Kerrie-Anne; Alonzo, Angelo; Somogyi, Andrew A; Loo, Colleen K

    2017-02-01

    Animal studies suggest that neural plasticity may play a role in the antidepressant effects of a single ketamine dose. However, the potential effects of repeated ketamine treatments on human neuroplasticity are unknown. This pilot RCT study measured plasticity-induced changes before and after a ketamine course, in three treatment-resistant depressed subjects, who were randomized to receive 8 intranasal treatments of 100mg ketamine or 4.5mg midazolam. Mood ratings were performed by a trained blinded rater at baseline and 24h-48h after the ketamine course, using the Montgomery Asberg Depression Rating Scale (MADRS). Neuroplasticity was assessed in the motor cortex using a paired associative stimulation (PAS) paradigm at baseline and 24h-48h after the treatment course. No changes in current psychotropic medication or dosage were permitted for 4weeks prior to trial entry and throughout the trial. The subject receiving ketamine, but not those receiving midazolam, presented a marked increase in neural plasticity after the treatment course. However, mood changes were not associated with changes in neural plasticity. Pilot study with small sample size. Concomitant antidepressant medications taken. Plasticity was tested in the motor cortex only, thus the generalizability of these findings to other brain areas cannot be assumed. These results suggest that a course of intranasal ketamine may enhance synaptic plasticity in subjects with depression, but this was not associated with antidepressant effects. Further research on this topic is warranted. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Living better in Nord-Pas de Calais region. For an energy turn and societal transformations - Full report, Synthesis

    International Nuclear Information System (INIS)

    2015-12-01

    In 2008, the NGO Virage-energie Nord-Pas de Calais published a scenario of nuclear power phaseout including objectives of reduction of green gas emissions in the region of Nord-Pas de Calais. In 2013, Virage-energie Nord-Pas de Calais published Scenarios on energy sufficiency and societal transformations: the results of a research project on the evaluation of energy savings potentials from public policies and lifestyle changes. Using data models and assumptions, this study has highlighted that energy sufficiency could generate energy savings from 26 % to 40 %. Global scenarios presented in this report, realised with the financial support of ADEME and regional council of the region Nord-Pas de Calais in partnership with two academic laboratories (TVES, University of Lille 1 - Science and Technologies; and Ceraps, University of Lille 2 - Health and Law), complete previous works with a global vision for the future energetic and social systems. Scenarios explore interactions between energy, lifestyles, agriculture, food habits, consumer goods, industry, buildings, transport and employment, in order to identify and to reduce human, social, economic and environmental vulnerabilities to energetic crisis. Energy sufficiency and resilience are at the heart of this research. Energy sufficiency is a voluntary and organized strategy to reduce energy consumption through lifestyles changes and societal transformations. Energy sufficiency is different from energy efficiency, which concerns only improvement of technical performances in order to reduce energy consumption of a system (building, vehicle, etc.). Sufficiency re-evaluates uses and needs of energy, but also imaginary and culture of a society and its individual and collective organisations. Resilience is the capacity for a system (territory, population, etc.) to absorb a perturbation, to reorganize itself and to continue to remain in a functionally similar state. Through three possible scenarios for the territory and the

  7. User's guide for remote access of the Performance Assessment Center

    International Nuclear Information System (INIS)

    Peterson, C.R.; Kostelnik, K.M.

    1991-03-01

    The Performance Assessment Center (PAC) was established by the Department of Energy's National Low-Level Waste Management Program to provide technical assistance to support the development of low-level radioactive waste disposal facilities. This user's manual provides guidance to remote users of the PAC. Information is presented on how remote users may most effectively access and use the systems available at the Performance Assessment Center in Idaho Falls, Idaho. Access requirements and operating procedures are presented to assist the first-time PAC user. This manual also provides brief descriptions of each code available on the system

  8. Input data required for specific performance assessment codes

    International Nuclear Information System (INIS)

    Seitz, R.R.; Garcia, R.S.; Starmer, R.J.; Dicke, C.A.; Leonard, P.R.; Maheras, S.J.; Rood, A.S.; Smith, R.W.

    1992-02-01

    The Department of Energy's National Low-Level Waste Management Program at the Idaho National Engineering Laboratory generated this report on input data requirements for computer codes to assist States and compacts in their performance assessments. This report gives generators, developers, operators, and users some guidelines on what input data is required to satisfy 22 common performance assessment codes. Each of the codes is summarized and a matrix table is provided to allow comparison of the various input required by the codes. This report does not determine or recommend which codes are preferable

  9. Building quality into performance and safety assessment software

    International Nuclear Information System (INIS)

    Wojciechowski, L.C.

    2011-01-01

    Quality assurance is integrated throughout the development lifecycle for performance and safety assessment software. The software used in the performance and safety assessment of a Canadian deep geological repository (DGR) follows the CSA quality assurance standard CSA-N286.7 [1], Quality Assurance of Analytical, Scientific and Design Computer Programs for Nuclear Power Plants. Quality assurance activities in this standard include tasks such as verification and inspection; however, much more is involved in producing a quality software computer program. The types of errors found with different verification methods are described. The integrated quality process ensures that defects are found and corrected as early as possible. (author)

  10. Iodine-129 Dose in LLW Disposal Facility Performance Assessments

    International Nuclear Information System (INIS)

    Wilhite, E.L.

    1999-01-01

    Iodine-129 has the lowest Performance Assessment derived inventory limit in SRS disposal facilities. Because iodine is concentrated in the body to one organ, the thyroid, it has been thought that dilution with stable iodine would reduce the dose effects of 129I.Examination of the dose model used to establish the Dose conversion factor for 129I shows that, at the levels considered in performance assessments of low-level waste disposal facilities, the calculated 129I dose already accounts for ingestion of stable iodine. At higher than normal iodine ingestion rates, the uptake of iodine by the thyroid itself decrease, which effectively cancels out the isotopic dilution effect

  11. Test report for PAS-1 cask certification for shipping payload B

    International Nuclear Information System (INIS)

    MERCADO, J.E.

    1998-01-01

    This test report documents the successful inspection and testing to certify two NuPac PAS-1 casks in accordance with US Department of Energy Certificate of Compliance (CoC) USA/9184/B(U). The primary and secondary containment vessels of each cask met the acceptance criteria defined in the CoC and the test plan

  12. Peer Relations and the Understanding of Faux Pas: Longitudinal Evidence for Bidirectional Associations

    Science.gov (United States)

    Banerjee, Robin; Watling, Dawn; Caputi, Marcella

    2011-01-01

    Research connecting children's understanding of mental states to their peer relations at school remains scarce. Previous work by the authors demonstrated that children's understanding of mental states in the context of a faux pas--a social blunder involving unintentional insult--is associated with concurrent peer rejection. The present report…

  13. 1 1) Pourquoi est-ce que je ne parviens pas à ouvrir les formulaires ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    IDRC CRDI

    Faites vos calculs avec soin car votre demande pourrait ne pas être admissible.) 6) Existe-t-il une liste de pays admissibles dans lesquels mon établissement ou organisme est autorisé à travailler ou à avoir des partenaires ? Non, le CRDI n'a rien de tel; cependant, il ne soutient des travaux que dans les pays à faible.

  14. Whole-genome sequence of Starmerella bacillaris PAS13, a nonconventional enological yeast with antifungal activity

    DEFF Research Database (Denmark)

    Lemos Junior, Wilson Jose Fernandes; Treu, Laura; Duarte, Vinicius da Silva

    2017-01-01

    Starmerella bacillaris is a fermentative yeast commonly found in vineyards. Here, we present the draft genome sequence of S. bacillaris PAS13, a nonconventional enological yeast with a potential role as a biocontrol agent. This gene sequence will provide insights into the genetic basis of yeast...

  15. Evidentiary requirements to identify potentially acceptable sites (PAS) in crystalline rock

    International Nuclear Information System (INIS)

    Comella, P.A.; Smith, B.H.

    1985-01-01

    This report contains information on the evidentiary requirements to identify potentially acceptable sites in crystalline rock for waste disposal. Topics addressed include: chronology, key regulatory assumptions, statutory framework for identifying potentially acceptable sites, application of 10 disqualifiers, consideration of favorable and potentially adverse conditions, a composite favorability analysis, and a proposed outline for PAS identification decision document

  16. Neuchatel ne gardera pas le Palais de l'equilibre apres Expo.02

    CERN Multimedia

    2002-01-01

    "La ville de Neuchatel ne souhaite pas conserver le Palais de l'equilibre apres Expo.02. Par 24 voix contre 7, le Conseil general a rejete le plan special du Conseil communal qui proposait de transformer l'edifice en un centre de congres" (1/2 page).

  17. THE NEED AND OPPORTUNITIES FOR PERFORMANCE ASSESSMENT IN HIGHER EDUCATION

    Directory of Open Access Journals (Sweden)

    Gabriella KECZER

    2007-01-01

    Full Text Available Motivating employees is one of the highly important areas of human resources management (HRM. As people are best motivated by their intention to satisfy their own needs, the task of HRM is to satisfy the employees’ need for remuneration in a fair and just manner. This can be achieved if an organization operates a formal and professional system of performance assessment. The importance of having such a system in place is further confirmed by the fact that six out of the seven large Hungarian corporations reviewed operate a global system of performance assessment. In areas where intellectual activity plays a dominant role, as is the case with higher education, omitting an evaluation of the performance of „white collar workers” is, of course, out of the question. Satisfying the employees’ need for fair remuneration in the public sphere, including higher education (HE, is essentially hindered by a lack of evaluating individual performance and, hence, performance-dependent wages and financial benefits derived from extra performance. Given the centrally determined and uniform wage schedule, there is almost no opportunity to differentiate between the performance of one person in a given wage category and another. This entails, at least for a large part of public employees and public servants, a lack of drive to perform better than average. These people could be forced to make greater efforts only by way of measuring their performance on an individual basis and applying a wage system that would rely on individual output and represent a system of wages that would be both differentiated and motivating. In the first part of my paper, I will present the performance assessment methods applied by the large Hungarian enterprises included in the investigation. The second part will deal with the issue of how all of this can be actually implemented in HE.

  18. Problems in developing an instrument for the rapid assessment of personality status.

    Science.gov (United States)

    Van Horn, E; Manley, C; Leddy, D; Cicchetti, D; Tyrer, P

    2000-06-01

    To assess the validity of a quick assessment instrument (10 minutes) for assessing personality status, the Rapid Personality Assessment Schedule (PAS-R). The PAS-R was evaluated in psychotic patients recruited in one of the centres involved in a multicentre randomised controlled trial of intensive vs standard case management (the UK700 case management trial). Patients were assessed using both a full version of the PAS (PAS-I - ICD version) and the PAS-R. The weighted kappa statistic was used to gauge the (criterion-related) validity of the PAS-R using the PAS-I as the gold standard. Both measure code personality status using a four-point rating of severity in addition to recording individual categories of personality disorder. One hundred fifty-five (77%) of 201 patients recruited were assessed with both instruments. The weighted kappa statistic was 0.31, suggesting only moderate agreement between the PAS-I and PAS-R instruments under the four-point rating format, and 0.39 for the dichotomous personality disorder/no disorder separation. The sensitivity (64%) and specificity (82%) of the PAS-R in predicting PAS-I personality disorder were as satisfactory as for other screening instruments but still somewhat disappointing, and the PAS-R had an overall diagnostic accuracy of 78%. The PAS-R is a quick and rough method of detecting personality abnormality but is not a substitute for a fuller assessment.

  19. Assessing the impact of blended learning on student performance

    OpenAIRE

    Do Won Kwak; Flavio Menezes; Carl Sherwood

    2013-01-01

    This paper assesses quantitatively the impact on student performance of a blended learning experiment within a large undergraduate first year course in statistics for business and economics students. We employ a differences- in-difference econometric approach, which controls for differences in student characteristics and course delivery method, to evaluate the impact of blended learning on student performance. Although students in the course manifest a preference for live lectures over online...

  20. Guidance on the Technology Performance Level (TPL) Assessment Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Jochem [National Renewable Energy Lab. (NREL), Golden, CO (United States); Roberts, Jesse D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Babarit, Aurelien [Ecole Centrale de Nantes (France). Lab. of Research in Hydrodynamics, Energetics and Atmospheric Environment (LHEEA); Costello, Ronan [Wave Venture, Penstraze (United Kingdom); Bull, Diana L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Neilson, Kim [Ramboll, Copenhagen (Denmark); Bittencourt, Claudio [DNV GL, London (United Kingdom); Kennedy, Ben [Wave Venture, Penstraze (United Kingdom); Malins, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dykes, Katherine [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    This document presents the revised Technology Performance Level (TPL) assessment methodology. There are three parts to this revised methodology 1) the Stakeholder Needs and Assessment Guidance (this document), 2) the Technical Submission form, 3) the TPL scoring spreadsheet. The TPL assessment is designed to give a technology neutral or agnostic assessment of any wave energy converter technology. The focus of the TPL is on the performance of the technology in meeting the customer’s needs. The original TPL is described in [1, 2] and those references also detail the critical differences in the nature of the TPL when compared to the more widely used technology readiness level (TRL). (Wave energy TRL is described in [3]). The revised TPL is particularly intended to be useful to investors and also to assist technology developers to conduct comprehensive assessments in a way that is meaningful and attractive to investors. The revised TPL assessment methodology has been derived through a structured Systems Engineering approach. This was a formal process which involved analyzing customer and stakeholder needs through the discipline of Systems Engineering. The results of the process confirmed the high level of completeness of the original methodology presented in [1] (as used in the Wave Energy Prize judging) and now add a significantly increased level of detail in the assessment and an improved more investment focused structure. The revised TPL also incorporates the feedback of the Wave Energy Prize judges.

  1. The balanced scorecard: sustainable performance assessment for forensic laboratories.

    Science.gov (United States)

    Houck, Max; Speaker, Paul J; Fleming, Arron Scott; Riley, Richard A

    2012-12-01

    The purpose of this article is to introduce the concept of the balanced scorecard into the laboratory management environment. The balanced scorecard is a performance measurement matrix designed to capture financial and non-financial metrics that provide insight into the critical success factors for an organization, effectively aligning organization strategy to key performance objectives. The scorecard helps organizational leaders by providing balance from two perspectives. First, it ensures an appropriate mix of performance metrics from across the organization to achieve operational excellence; thereby the balanced scorecard ensures that no single or limited group of metrics dominates the assessment process, possibly leading to long-term inferior performance. Second, the balanced scorecard helps leaders offset short term performance pressures by giving recognition and weight to long-term laboratory needs that, if not properly addressed, might jeopardize future laboratory performance. Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  2. Assessment of Residents Readiness to Perform Lumbar Puncture

    DEFF Research Database (Denmark)

    Henriksen, Mikael Johannes Vuokko; Wienecke, Troels; Thagesen, Helle

    2017-01-01

    and 18 novices performing the procedure in a simulated, ward-like setting with a standardized patient. Procedural performance was assessed by three content experts. We used generalizability theory to explore reliability. The discriminative ability of the tool was explored by comparing performance scores......Background: Lumbar puncture is a common procedure in many specialties. The procedure serves to diagnose life-threatening conditions, often requiring rapid performance. However, junior doctors possess uncertainties regarding performing the procedure and frequently perform below expectations. Hence...... between the two groups. The contrasting groups method was used to set a pass/fail standard and the consequences of this was explored. Key results: The interviews identified that in addition to the technical aspects of the procedure, non-technical elements involving planning and conducting the procedure...

  3. Peer assessment of aviation performance: inconsistent for good reasons.

    Science.gov (United States)

    Roth, Wolff-Michael; Mavin, Timothy J

    2015-03-01

    Research into expertise is relatively common in cognitive science concerning expertise existing across many domains. However, much less research has examined how experts within the same domain assess the performance of their peer experts. We report the results of a modified think-aloud study conducted with 18 pilots (6 first officers, 6 captains, and 6 flight examiners). Pairs of same-ranked pilots were asked to rate the performance of a captain flying in a critical pre-recorded simulator scenario. Findings reveal (a) considerable variance within performance categories, (b) differences in the process used as evidence in support of a performance rating, (c) different numbers and types of facts (cues) identified, and (d) differences in how specific performance events affect choice of performance category and gravity of performance assessment. Such variance is consistent with low inter-rater reliability. Because raters exhibited good, albeit imprecise, reasons and facts, a fuzzy mathematical model of performance rating was developed. The model provides good agreement with observed variations. Copyright © 2014 Cognitive Science Society, Inc.

  4. Assessing vocal performance in complex birdsong: a novel approach.

    Science.gov (United States)

    Geberzahn, Nicole; Aubin, Thierry

    2014-08-06

    Vocal performance refers to the ability to produce vocal signals close to physical limits. Such motor skills can be used by conspecifics to assess a signaller's competitive potential. For example it is difficult for birds to produce repeated syllables both rapidly and with a broad frequency bandwidth. Deviation from an upper-bound regression of frequency bandwidth on trill rate has been widely used to assess vocal performance. This approach is, however, only applicable to simple trilled songs, and even then may be affected by differences in syllable complexity. Using skylarks (Alauda arvensis) as a birdsong model with a very complex song structure, we detected another performance trade-off: minimum gap duration between syllables was longer when the frequency ratio between the end of one syllable and the start of the next syllable (inter-syllable frequency shift) was large. This allowed us to apply a novel measure of vocal performance ¿ vocal gap deviation: the deviation from a lower-bound regression of gap duration on inter-syllable frequency shift. We show that skylarks increase vocal performance in an aggressive context suggesting that this trait might serve as a signal for competitive potential. We suggest using vocal gap deviation in future studies to assess vocal performance in songbird species with complex structure.

  5. Assessing Performance and Learning in Interprofessional Health Care Teams.

    Science.gov (United States)

    Ekmekci, Ozgur; Sheingold, Brenda; Plack, Margaret; LeLacheur, Susan; Halvaksz, Jennifer; Lewis, Karen; Schlumpf, Karen; Greenberg, Larrie

    2015-01-01

    Teamwork has become an integral part of health care delivery. Such emphasis on teamwork has generated the need to systematically measure and improve the learning and performance of health care teams. The purpose of this study was to develop a comprehensive assessment instrument, the Interprofessional Education and Practice Inventory (IPEPI), to evaluate learning and performance in interprofessional health care teams. The 12-month study commenced in three 4-month phases: (1) a panel of 25 national and international experts participated in the Delphi process to identify factors influencing team learning and team performance; (2) the research team analyzed the findings from the two Delphi rounds to develop the IPEPI; and (3) a cohort of 27 students at the university engaged in clinical simulations to test and refine the IPEPI. Findings suggest key factors that significantly influence team learning and performance include whether the group is able to foster a climate of mutual respect, adopt effective communication strategies, develop a sense of trust, and invite contributions from others. Additionally, in assessing organizational factors, participants indicated those factors that significantly influence team learning and performance include whether the organization is patient-centered, creates a culture of safety (not blame), and supports individual and team learning. These findings highlight the critical role assessment plays in enhancing not just interprofessional education or interprofessional practice, but in essence advancing interprofessional education and practice--which requires an integrated examination of how health care professionals learn and perform in teams.

  6. Technology-Supported Performance Assessments for Middle School Geoscience

    Science.gov (United States)

    Zalles, D. R.; Quellmalz, E.; Rosenquist, A.; Kreikemeier, P.

    2002-12-01

    Under funding from the World Bank, the U.S. Department of Education, the National Science Foundation, and the Federal Government's Global Learning and Observations to Benefit the Environment Program (GLOBE), SRI International has developed and piloted web-accessible performance assessments that measure K-12 students' abilities to use learning technologies to reason with scientific information and communicate evidence-based conclusions to scientific problems. This presentation will describe the assessments that pertain to geoscience at the middle school level. They are the GLOBE Assessments and EPA Phoenix, an instantiation of SRI's model of assessment design known as Integrative Performance Assessments in Technology (IPAT). All are publicly-available on the web. GLOBE engages students in scientific data collection and observation about the environment. SRI's classroom assessments for GLOBE provide sample student assessment tools and frameworks that allow teachers and students to assess how well students can use the data in scientific inquiry projects. Teachers can use classroom assessment tools on the site to develop integrated investigations for assessing GLOBE within their particular science curricula. Rubrics are provided for measuring students' GLOBE-related skills, and alignments are made to state, national, and international science standards. Sample investigations are provided about atmosphere, hydrology, landcover, soils, earth systems, and visualizations. The IPAT assessments present students with engaging problems rooted in science or social science content, plus sets of tasks and questions that require them to gather relevant information on the web, use reasoning strategies to analyze and interpret the information, use spreadsheets, word processors, and other productivity tools, and communicate evidence-based findings and recommendations. In the process of gathering information and drawing conclusions, students are assessed on how well they can operate

  7. Assessment of Innovation and Performance in the Fruit Chain; The Innovation-Performance Matrix

    NARCIS (Netherlands)

    Trienekens, J.H.; Uffelen, van R.L.M.; Debaire, J.; Omta, S.W.F.

    2008-01-01

    Purpose - This paper aims to bridge the concepts of innovation and performance and to develop a framework to assess innovation and performance in food chains. Design/methodology/approach - Based on an extensive literature search the paper identifies critical success factors (CSFs) and related

  8. Organizational Performance Assessment: Overview of Publications in National Journals

    Directory of Open Access Journals (Sweden)

    Sandra Mara Iesbik Valmorbida

    2012-12-01

    Full Text Available In the literature there are several tools that aim to assess organizational performance, such as Balanced Scorecard (BSC, National Quality Award (PNQ, Multicriteria Methodology for Decision Aiding (MCDA, Data envelopment analysis (DEA, Analytic Hierarchy Process (AHP, among others. However, it is perceived in practice doubts as to choose the most appropriate for each organizational context. In this sense, it is argued that to measure the performance of the organization it is necessary that this measure is based on an instrument that allows transparency in the evaluation form, and insert those interested in the evaluation process. The credibility of an evaluation therefore depends on the ability to produce consistent information for all subjects involved in the intervention. The search for tools to improve the way to evaluate organizational performance it is increasingly necessary. The objective of this study is to identify the main tools of organizational performance assessment published in national journals in the area of Administration, Accounting and Tourism, classified by CAPES Qualis A1 to B5. The study is characterized as descriptive and qualitative documentation. We analyzed 489 articles, which resulted in the following results:(i identified the main theme of the authors and regular assessment of organizational performance, (ii from the year 2000 publications on the subject grew substantially, (iii Data Envelopment Analysis (DEA, Balanced Scorecard (BSC and Multicriteria for decision aiding methodology(MCDA-C are the most commonly used tools for evaluating performance, (iv most of the tools found in the literature are multiple criteria, (v described the process used by the tools to assess organizational performance.

  9. Methodology for assessing performance of waste management systems

    International Nuclear Information System (INIS)

    Meshkov, N.K.; Herzenberg, C.L.; Camasta, S.F.

    1988-01-01

    The newly revised draft DOE Order 5820.2, Chapter 3, requires that DOE low-level waste shall be managed on a systematic basis using the most appropriate combination of waste generation reduction, segregation, treatment, and disposal practices so that the radioactive components are contained and the overall cost effectiveness is minimized. This order expects each site to prepare and maintain an overall waste management systems performance assessment supporting the combination of waste management practices used in generation reduction segregation, treatment, packaging, storage, and disposal. A document prepared by EG and G Idaho, Inc. for the Department of Energy called Guidance for Conduct of Waste Management Systems Performance Assessment is specifically intended to provide the approach necessary to meet the systems performance assessment requirement of DOE Order 5820.2, Chapter 3, and other applicable state regulations dealing with LLW (low-level radioactive wastes). Methods and procedures are needed for assessing the performance of a waste management system. This report addresses this need. The purpose of the methodology provided in this report is to select the optimal way to manage particular sets of waste streams from generation to disposal in a safe and cost-effective manner, and thereby assist the DOE LLW mangers in complying with the DOE Order 5820.2, Chapter 3, and the associated guidance document

  10. Counselor Competence, Performance Assessment, and Program Evaluation: Using Psychometric Instruments

    Science.gov (United States)

    Tate, Kevin A.; Bloom, Margaret L.; Tassara, Marcel H.; Caperton, William

    2014-01-01

    Psychometric instruments have been underutilized by counselor educators in performance assessment and program evaluation efforts. As such, we conducted a review of the literature that revealed 41 instruments fit for such efforts. We described and critiqued these instruments along four dimensions--"Target Domain," "Format,"…

  11. Workplace-based assessment: raters' performance theories and constructs

    NARCIS (Netherlands)

    Govaerts, M.J.; Wiel, M.W.J. van de; Schuwirth, L.W.; Vleuten, C.P.M. van der; Muijtjens, A.M.M.

    2013-01-01

    Weaknesses in the nature of rater judgments are generally considered to compromise the utility of workplace-based assessment (WBA). In order to gain insight into the underpinnings of rater behaviours, we investigated how raters form impressions of and make judgments on trainee performance. Using

  12. Data farming in support of HLA performance assessment

    NARCIS (Netherlands)

    Cramp, A.J.; Berg, T.W. van den; Huiskamp, W.

    2014-01-01

    Performance assessment is a key factor in designing distributed simulation environments that are fit-forpurpose and cost-effective. Simulations used for training applications should provide the required level of responsiveness and interactivity. Simulations used for analysis or decision support

  13. Personnel Performance Assessment in Information Systems Outsourcing Environments

    Science.gov (United States)

    Casado-Lumbreras, Cristina; Soto-Acosta, Pedro; Colomo-Palacios, Ricardo; de Pablos, Patricia Ordonez

    2011-01-01

    Purpose: The aim of this paper is to present a tool which uses semantic technologies for personnel performance and workplace learning assessment in outsourced information technology environments. Design/methodology/approach: The paper presents the tool from a technical perspective and introduces a use case that depicts the main features related to…

  14. Annual Performance Reports: 2002-2003 State Assessment Data

    Science.gov (United States)

    Thurlow, Martha L.; Moen, Ross E.; Wiley, Hilda I.

    2005-01-01

    States and other educational entities receiving Part B funding under the Individuals with Disabilities Education Act (IDEA) submitted their Annual Performance Reports to the U.S. Secretary of Education on or before March 31, 2004. These reports contained information on a variety of indicators, including assessment participation and performance…

  15. Performance assessment development for a LILW repository in Slovenia

    International Nuclear Information System (INIS)

    Zeleznik, N.; Mele, I.

    2001-01-01

    Simultaneously with the site selection process for a low and intermediate level radioactive waste (LILW) repository, the preliminary assessment of the influence of the specific disposal concept on the environment and on the population was developed. The performance assessment team, organized in 1997 by ARAO, prepared several basic studies in order to clarify the objectives of the performance and safety assessment (PA/SA) procedure. In 1999 also the first performance assessment of two safety cases (surface and underground) for generic site for a LILW repository was realized. In the year 2000 activities on PA/SA analyses continued. A systematic, generic list was prepared of all possible features, events and processes (FEP list) predictable for surface or underground LILW disposal in Slovenia. Recommended and selected were the most reliable scenarios with conceptual models for LILW disposal in normal and altered evolution conditions. New verification of the obtained results was done with more powerful and accurate models for the surface repository over an aquifer of lower water permeability and an underground repository in a plastic rock. The results for both generic cases under normal evolution scenarios showed that there is a negligible dose influence on members of the critical population due to the migration of radionuclides from the foreseen LILW repository. The results of the already performed work as well as plans for the future activities are presented in the paper.(author)

  16. Optimal Designs for Performance Assessments: The Subject Factor.

    Science.gov (United States)

    Parkes, Jay

    Much speculation abounds concerning how expensive performance assessments are or are going to be. Recent projections indicate that, in order to achieve an acceptably high generalizability coefficient, many additional tasks may need to be added, which will enlarge costs. Such projections are, to some degree, correct, and to some degree simplistic.…

  17. Measuring the Impact of Rater Negotiation in Writing Performance Assessment

    Science.gov (United States)

    Trace, Jonathan; Janssen, Gerriet; Meier, Valerie

    2017-01-01

    Previous research in second language writing has shown that when scoring performance assessments even trained raters can exhibit significant differences in severity. When raters disagree, using discussion to try to reach a consensus is one popular form of score resolution, particularly in contexts with limited resources, as it does not require…

  18. Reliable and Valid Assessment of Clinical Bronchoscopy Performance

    DEFF Research Database (Denmark)

    Konge, Lars; Larsen, Klaus Richter; Clementsen, Paul

    2012-01-01

    : The interrater reliability was high, with Cronbach's a = 0.86. Assessment of 3 bronchoscopies by a single rater had a generalizability coefficient of 0.84. The correlation between experience and performance was good (Pearson correlation = 0.76). There were significant differences between the groups for all...

  19. Performance Assessment of a Class of Industrial Fans With ...

    African Journals Online (AJOL)

    This paper presents a statistical quality control study for on-condition monitoring of draught fans in a steelmaking process. The study proposes a procedure for obtaining consistent estimates of peak vibration levels for performance assessment the machines based on independent measurements of the variable assuming the ...

  20. Radionuclide release rates from spent fuel for performance assessment modeling

    International Nuclear Information System (INIS)

    Curtis, D.B.

    1994-01-01

    In a scenario of aqueous transport from a high-level radioactive waste repository, the concentration of radionuclides in water in contact with the waste constitutes the source term for transport models, and as such represents a fundamental component of all performance assessment models. Many laboratory experiments have been done to characterize release rates and understand processes influencing radionuclide release rates from irradiated nuclear fuel. Natural analogues of these waste forms have been studied to obtain information regarding the long-term stability of potential waste forms in complex natural systems. This information from diverse sources must be brought together to develop and defend methods used to define source terms for performance assessment models. In this manuscript examples of measures of radionuclide release rates from spent nuclear fuel or analogues of nuclear fuel are presented. Each example represents a very different approach to obtaining a numerical measure and each has its limitations. There is no way to obtain an unambiguous measure of this or any parameter used in performance assessment codes for evaluating the effects of processes operative over many millennia. The examples are intended to suggest by example that in the absence of the ability to evaluate accuracy and precision, consistency of a broadly based set of data can be used as circumstantial evidence to defend the choice of parameters used in performance assessments

  1. An importance-performance assessment of delegates' satisfaction ...

    African Journals Online (AJOL)

    An importance-performance assessment of delegates' satisfaction with the catering component of courses offered by continuing education at the University of ... of its catering component, a company would be able to make appropriate and necessary managerial decisions in order to retain and expand its customer base.

  2. Assessment of the Outreach Performance of Special Programme on ...

    African Journals Online (AJOL)

    Assessment of the Outreach Performance of Special Programme on Food Security in Abia State, Nigeria. ... Four variables namely level of education, skill acquisition in off farm activities, farm size, and loan transaction costs produced significant influence on the amount of loan demanded. R2 value of 0.529 indicates that the ...

  3. The Neglected Situation: Assessment Performance and Interaction in Context

    Science.gov (United States)

    Maddox, Bryan

    2015-01-01

    Informed by Goffman's influential essay on "The neglected situation" this paper examines the contextual and interactive dimensions of performance in large-scale educational assessments. The paper applies Goffman's participation framework and associated theory in linguistic anthropology to examine how testing situations are framed and…

  4. Teacher Performance Assessment in Teacher Education: An Example in Malaysia

    Science.gov (United States)

    Gallant, Andrea; Mayer, Diane

    2012-01-01

    As part of a cross-cultural collaboration, a teacher performance assessment (TPA) was implemented during 2009 in three Malaysian institutes of teacher education. This paper reports on the TPA for graduating primary teachers in Malaysia. The investigation focused on the pre-service teachers' perceptions about whether the TPA provided them with an…

  5. Self-Assessment in Mathematics as Correlate of Performance of ...

    African Journals Online (AJOL)

    This study was conducted to investigate the relationship between students self assessment in Mathematics and academic performance in Senior Secondary School Physics. The research is descriptive and of the survey type as there was no treatment and manipulation of subjects. Instead it involves the use of questionnaire ...

  6. Operational risk assessments by supply chain professionals : process and performance

    NARCIS (Netherlands)

    Tazelaar, F.; Snijders, C.C.P.

    2013-01-01

    We consider the "process-performance paradox" in the assessment of operational risks by professionals in the field of operations and supply chain management (OSCM). The paradox states that although professionals with more expertise tend to decide in different ways, they often do not make better

  7. Deep geologic disposal. Lessons learnt from recent performance assessment studies

    International Nuclear Information System (INIS)

    Pescatore, C.; Andersson, J.

    1998-01-01

    Performance assessment (PA) studies are part of the decision basis for the siting, operation, and closure of deep repositories of long-lived nuclear wastes. In 1995 the NEA set up the Working Group on Integrated Performance Assessments of Deep Repositories (IPAG) with the goals to analyse existing PA studies, learn about what has been produced to date, and shed light on what could be done in future studies. Ten organisations submitted their most recent PA study for analysis and discussion, including written answers to over 70 questions. Waste management programmes, disposal concepts, geologies, and different types and amounts of waste offered a unique opportunity for exchanging information, assessing progress in PA since 1990, and identifying recent trends. A report was completed whose main lessons are overviewed. (author)

  8. Environmental performance assessment of a company of aluminum surface treatment

    Directory of Open Access Journals (Sweden)

    Susan Catieri Ramalho

    2013-08-01

    Full Text Available The purpose of this article was to evaluate the environmental performance of a medium-sized company that provides services for surface treatment of aluminum. The treatment is known as anodizing. The research method was qualitative numerical modeling. The environmental performance of the company was organized into five constructs: atmosphere, wastewater, energy and natural resources, solid waste, and legislation and management. Nineteen indicators were chosen to explain the five constructs. Ten employees of the company prioritized the constructs and evaluated the situation of the indicators by means of a scale of assessment. By means of a mathematical model, the general performance of the environmental operation was calculated at 74.5% of the maximum possible. The indicators that most contributed to the performance not to reach 100% were consumption of electricity and water consumption. The construct of worse performance was natural and energy resources. These are the priorities for future environmental improvement actions that the company may promote.

  9. Measurements of Cs 137 and Cs 134 internal contamination during 1987 by the Bologna Enea PAS whole body counter

    International Nuclear Information System (INIS)

    Melandri, C.; Castellani, C.M.; Torroni, G.; Formignani, M.

    1988-01-01

    Internal contamination data obtained during 1987 at the ENEA PAS-FIBI- AEROSOL Laboratory in Bologna, following the accident at the nuclear reactor in Chernobyl, are presented. The data are referred to person living in the Bologna area, in other Italian regions and to individuals returned from abroad, mainly from Eastern Europe countries. Trend of Cs-137 and Cs-134 internal body burden in adult men resident in Bologna are given together with values of mean daily intake by ingestion and evaluation of the commited dose equivalents up to decembre 1987. Measurement campaigns, specifically projected in order to evaluate the men/women activity differences and the distribution of the internal contamination in various Italian regions, have been performed

  10. Performance assessment experience at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Lee, D.W.

    1994-01-01

    The development of a performance assessment (PA) for low-level radioactive waste disposal operations at Oak Ridge National Laboratory (ORNL) was initiated in 1989 and is continuing. A draft PA was prepared in September 1990 and submitted to the DOE Peer Review Panel for review and comment. Recommendations were received that formed the basis for a revised PA that was completed in December 1993. The review of the revised PA is continuing. This paper reviews the experience gained in the preparation of the PA including the technical difficulties associated with performance assessment in Oak Ridge and an overview of the methods used in the PA. Changes in waste operations that resulted from the findings in the PA include improved waste acceptance criteria, waste certification, and waste management practices. The discussion includes issues that relate to the application of current performance objectives to older disposal facilities, which are being addressed as part of the CERCLA process

  11. Total-System Performance Assessment for the Yucca Mountain Site

    International Nuclear Information System (INIS)

    Wilson, M.L.

    2001-01-01

    Yucca Mountain, Nevada, is under consideration as a potential site for a repository for high-level radioactive waste. Total-system performance-assessment simulations are performed to evaluate the safety of the site. Features, events, and processes have been systematically evaluated to determine which ones are significant to the safety assessment. Computer models of the disposal system have been developed within a probabilistic framework, including both engineered and natural components. Selected results are presented for three different total-system simulations, and the behavior of the disposal system is discussed. The results show that risk is dominated by igneous activity at early times, because the robust waste-package design prevents significant nominal (non-disruptive) releases for tens of thousands of years or longer. The uncertainty in the nominal performance is dominated by uncertainties related to waste-package corrosion at early times and by uncertainties in the natural system, most significantly infiltration, at late times

  12. How Should Blood Glucose Meter System Analytical Performance Be Assessed?

    Science.gov (United States)

    Simmons, David A

    2015-08-31

    Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.

  13. Hardware performance assessment recommendations and tools for baropodometric sensor systems

    Directory of Open Access Journals (Sweden)

    Claudia Giacomozzi

    2010-06-01

    Full Text Available Accurate plantar pressure measurements are mandatory in both clinical and research contexts. Differences in accuracy, precision, reliability of pressure measurement devices (PMDs prevented so far the onset of standardization processes and of reliable reference datasets. The Italian National Institute of Health (ISS approved and conducted a scientific project aimed to design, validate and implement dedicated testing methods for both in-factory and on-the-field PMD assessment. A general-purpose experimental set-up was built, complete and suitable for the assessment of PMDs based on different sensor technology, electronic conditioning and mechanical solutions. Preliminary assessments have been conducted on 5 commercial PMDs. The study lead to the definition of: i an appropriate set of instruments and procedures for PMD technical assessment; ii a minimum set of significant parameters for the technical characterization of the PMD performance; iii some recommendations to both manufacturers and end users for an appropriate use in clinics and in research context

  14. Consideration of liners and covers in performance assessments

    Energy Technology Data Exchange (ETDEWEB)

    Phifer, Mark A. [Savannah River National Laboratory, Aiken, SC (United States); Seitz, Robert R. [Savannah River National Laboratory, Aiken, SC (United States); Suttora, Linda C. [USDOE Enviromental Management, Washington, DC (United States)

    2014-09-18

    On-site disposal cells are in use and being considered at several United States Department of Energy (USDOE) sites as the final disposition for large amounts of waste associated with cleanup of contaminated areas and facilities. These disposal cells are typically regulated by States and/or the U.S. Environmental Protection Agency under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) in addition to having to comply with requirements in DOE Order 435.1, Radioactive Waste Management due to the radioactive waste. The USDOE-Environmental Management Office of Site Restoration formed a working group to foster improved communication and sharing of information for personnel associated with these CERCLA disposal cells and work towards more consistent assumptions, as appropriate, for technical and policy considerations related to CERCLA risk assessments and DOE Order 435.1 performance assessments in support of a Record of Decision and Disposal Authorization Statement, respectively. One of the issues considered by the working group, which is addressed in this report, was how to appropriately consider the performance of covers and liners/leachate collections systems in the context of a DOE Order 435.1 performance assessment (PA). This same information may be appropriate for consideration within CERCLA risk assessments for these facilities. These OSDCs are generally developed to meet hazardous waste (HW) disposal design standards under the Resource Conservation and Recovery Act (RCRA) as well as the DOE Order 435.1 performance based standards for disposal of radioactive waste. To meet the standards for HW, the facilities typically include engineered covers and liner/leachate collection systems. Thus, when considering such facilities in the context of a DOE Order 435.1 PA, there is a need to address the evolution of performance of covers and liner/leachate collection systems in the context of meeting a performance standard considering time

  15. PAS positivity of erythroid precursor cells is associated with a poor prognosis in newly diagnosed myelodysplastic syndrome patients.

    Science.gov (United States)

    Masuda, Kenta; Shiga, Shuichi; Kawabata, Hiroshi; Takaori-Kondo, Akifumi; Ichiyama, Satoshi; Kamikubo, Yasuhiko

    2018-07-01

    Myelodysplastic syndrome (MDS) is a group of clonal stem cell disorders characterized by hematopoietic insufficiency. The accurate risk stratification of patients with MDS is essential for selection of appropriate therapies. We herein conducted a retrospective cohort study to examine the prognostic value of periodic acid-Schiff (PAS) reaction-positive erythroblasts in MDS patients. We examined the PAS positivity of the bone marrow erythroblasts of 144 patients newly diagnosed with MDS; 26 (18.1%) of them had PAS-positive erythroblasts, whereas 118 (81.9%) did not. The PAS-positive group showed significantly poorer karyotypes as defined in the revised International Prognostic Scoring System (IPSS-R) and higher scores in age-adjusted IPSS-R (IPSS-RA) than the PAS-negative group. Overall survival (OS) and leukemia-free survival (LFS) were also significantly shorter in the PAS-positive group than in the PAS-negative group. Similar results were obtained when only high- and very high risk groups were analyzed using IPSS-RA. This retrospective study suggested that the PAS positivity of erythroblasts is an additional prognostic factor combined with other risk scores for OS and LFS in MDS, and our results may contribute to improved clinical decision-making and rapid risk stratification.

  16. Performance Assessment and Geometric Calibration of RESOURCESAT-2

    Science.gov (United States)

    Radhadevi, P. V.; Solanki, S. S.; Akilan, A.; Jyothi, M. V.; Nagasubramanian, V.

    2016-06-01

    Resourcesat-2 (RS-2) has successfully completed five years of operations in its orbit. This satellite has multi-resolution and multi-spectral capabilities in a single platform. A continuous and autonomous co-registration, geo-location and radiometric calibration of image data from different sensors with widely varying view angles and resolution was one of the challenges of RS-2 data processing. On-orbit geometric performance of RS-2 sensors has been widely assessed and calibrated during the initial phase operations. Since then, as an ongoing activity, various geometric performance data are being generated periodically. This is performed with sites of dense ground control points (GCPs). These parameters are correlated to the direct geo-location accuracy of the RS-2 sensors and are monitored and validated to maintain the performance. This paper brings out the geometric accuracy assessment, calibration and validation done for about 500 datasets of RS-2. The objectives of this study are to ensure the best absolute and relative location accuracy of different cameras, location performance with payload steering and co-registration of multiple bands. This is done using a viewing geometry model, given ephemeris and attitude data, precise camera geometry and datum transformation. In the model, the forward and reverse transformations between the coordinate systems associated with the focal plane, payload, body, orbit and ground are rigorously and explicitly defined. System level tests using comparisons to ground check points have validated the operational geo-location accuracy performance and the stability of the calibration parameters.

  17. Circadian rhythms in cognitive performance: implications for neuropsychological assessment

    Directory of Open Access Journals (Sweden)

    Valdez P

    2012-12-01

    Full Text Available Pablo Valdez, Candelaria Ramírez, Aída GarcíaLaboratory of Psychophysiology, School of Psychology, University of Nuevo León, Monterrey, Nuevo León, MéxicoAbstract: Circadian variations have been found in human performance, including the efficiency to execute many tasks, such as sensory, motor, reaction time, time estimation, memory, verbal, arithmetic calculations, and simulated driving tasks. Performance increases during the day and decreases during the night. Circadian rhythms have been found in three basic neuropsychological processes (attention, working memory, and executive functions, which may explain oscillations in the performance of many tasks. The time course of circadian rhythms in cognitive performance may be modified significantly in patients with brain disorders, due to chronotype, age, alterations of the circadian rhythm, sleep deprivation, type of disorder, and medication. This review analyzes the recent results on circadian rhythms in cognitive performance, as well as the implications of these rhythms for the neuropsychological assessment of patients with brain disorders such as traumatic head injury, stroke, dementia, developmental disorders, and psychiatric disorders.Keywords: human circadian rhythms, cognitive performance, neuropsychological assessment, attention, working memory, executive functions

  18. Drawing students' attention to relevant assessment criteria: effects on self-assessment skills and performance

    NARCIS (Netherlands)

    Fastré, Greet; Van der Klink, Marcel; Sluijsmans, Dominique; Van Merriënboer, Jeroen

    2012-01-01

    Fastré, G. M. J., Van der Klink, M. R., Sluijsmans, D., & Van Merriënboer, J. J. G. (2012). Drawing students’ attention to relevant assessment criteria: effects on self-assessment skills and performance. Journal of Vocational Education & Training, 64(2), 185-198. doi:10.1080/13636820.2011.630537

  19. Performance assessment plans and methods for the Salt Repository Project

    International Nuclear Information System (INIS)

    1984-08-01

    This document presents the preliminary plans and anticipated methods of the Salt Repository Project (SRP) for assessing the postclosure and radiological aspects of preclosure performance of a nuclear waste repository in salt. This plan is intended to be revised on an annual basis. The emphasis in this preliminary effort is on the method of conceptually dividing the system into three subsystems (the very near field, the near field, and the far field) and applying models to analyze the behavior of each subsystem and its individual components. The next revision will contain more detailed plans being developed as part of Site Characterization Plan (SCP) activities. After a brief system description, this plan presents the performance targets which have been established for nuclear waste repositories by regulatory agencies (Chapter 3). The SRP approach to modeling, including sensitivity and uncertainty techniques is then presented (Chapter 4). This is followed by a discussion of scenario analysis (Chapter 5), a presentation of preliminary data needs as anticipated by the SRP (Chapter 6), and a presentation of the SRP approach to postclosure assessment of the very near field, the near field, and the far field (Chapters 7, 8, and 9, respectively). Preclosure radiological assessment is discussed in Chapter 10. Chapter 11 presents the SRP approach to code verification and validation. Finally, the Appendix lists all computer codes anticipated for use in performance assessments. The list of codes will be updated as plans are revised

  20. The Waste Isolation Pilot Plant Performance Assessment Program

    International Nuclear Information System (INIS)

    Myers, J.; Coons, W.E.; Eastmond, R.; Morse, J.; Chakrabarti, S.; Zurkoff, J.; Colton, I.D.; Banz, I.

    1986-01-01

    The Waste Isolation Pilot Plant (WIPP) Performance Assessment Program involves a comprehensive analysis of the WIPP project with respect to the recently finalized Environmental Protection Agency regulations regarding the long-term geologic isolation of radioactive wastes. The performance assessment brings together the results of site characterization, underground experimental, and environmental studies into a rigorous determination of the performance of WIPP as a disposal system for transuranic radioactive waste. The Program consists of scenario development, geochemical, hydrologic, and thermomechanical support analyses and will address the specific containment and individual protection requirements specified in 40 CFR 191 sub-part B. Calculated releases from these interrelated analyses will be reported as an overall probability distribution of cumulative release resulting from all processes and events occurring over the 10,000 year post-closure period. In addition, results will include any doses to the public resulting from natural processes occurring over the 1,000 year post-closure period. The overall plan for the WIPP Performance Assessment Program is presented along with approaches to issues specific to the WIPP project

  1. Self-assessment of human performance errors in nuclear operations

    International Nuclear Information System (INIS)

    Chambliss, K.V.

    1996-01-01

    One of the most important approaches to improving nuclear safety is to have an effective self-assessment process in place, whose cornerstone is the identification and improvement of human performance errors. Experience has shown that significant events usually have had precursors of human performance errors. If these precursors are left uncorrected or not understood, the symptoms recur and result in unanticipated events of greater safety significance. The Institute of Nuclear Power Operations (INPO) has been championing the cause of promoting excellence in human performance in the nuclear industry. INPO's report, open-quotes Excellence in Human Performance,close quotes emphasizes the importance of several factors that play a role in human performance. They include individual, supervisory, and organizational behaviors; real-time feedback that results in specific behavior to produce safe and reliable performance; and proactive measures that remove obstacles from excellent human performance. Zack Pate, chief executive officer and president of INPO, in his report, open-quotes The Control Room,close quotes provides an excellent discussion of serious events in the nuclear industry since 1994 and compares them with the results from a recent study by the National Transportation Safety Board of airline accidents in the 12-yr period from 1978 to 1990 to draw some common themes that relate to human performance issues in the control room

  2. Assessing the performance of the Nagra HLW disposal concept

    International Nuclear Information System (INIS)

    Smith, P.; Zuidema, P.; McKinley, I.G.

    1995-01-01

    This article outlines the procedures used in safety assessment and illustrates their application in evaluating the performance of a high-level waste repository. Nagra's general safety assessment methodology has five main components: formulating the aims of the analysis, defining the safety concept, scenario development, consequence analysis and interpretation of results. A safety analysis based on conservative assumptions shows that the engineered barriers of the high-level waste repository are very effective in preventing release of radionuclides; this alone is sufficient to ensure that regulatory requirements can be met. The function of the host rock is to provide a favourable environment for the engineered barrier system. (author) 8 figs

  3. Historical data summary of the systematic assessment of licensee performance

    International Nuclear Information System (INIS)

    Allenspach, F.

    1992-08-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following-sections: Section I presents the most recent SALE report ratings for facilities in operation and under construction. Section 2 presents a chronological listing of all SALE report ratings for each operating facility. Section 3 presents a chronological listing of all SALP report ratings for each facility under construction. For historical purposes, past construction ratings for facilities that recently have been licensed also are listed in Section 3

  4. Historical data summary of the systematic assessment of licensee performance

    International Nuclear Information System (INIS)

    Allenspach, F.

    1991-08-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following sections: Section 1 presents the most recent SALP report ratings for facilities in operation and under construction. Section 2 presents a chronological listing of all SALP report ratings for each operating facility. Section 3 presents a chronological listing of all SALP report ratings for each facility under construction. For historical purposes, past construction ratings for facilities that recently have been licensed also are listed in Section 3

  5. Historical data summary of the systematic assessment of licensee performance

    International Nuclear Information System (INIS)

    Allenspach, F.

    1993-02-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following-sections: Section 1 presents the most recent SALP report ratings for facilities in operation and under construction. Section 2 presents a chronological listing of all SALP report ratings for each operating facility. Section 3 for each facility under construction. For historical purposes, past construction ratings for facilities that recently have been licensed also are listed in Section 3

  6. Historical data summary of the systematic assessment of licensee performance

    International Nuclear Information System (INIS)

    Allenspach, F.; Wharton, R.

    1990-08-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following sections: Section 1 presents the most recent SALP report ratings for facilities in operation and under construction. Section 2 presents a chronological listing of all SALP report ratings for each operating facility. Section 3 presents a chronological listing of all SALP report ratings for each facility under construction. For historical purposes, past construction ratings for facilities that recently have been licensed also are listed in Section 3

  7. Historical data summary of the Systematic Assessment of Licensee Performance

    International Nuclear Information System (INIS)

    Allenspach, F.

    1993-08-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following sections: Section 1 presents the most recent SALP report ratings for facilities in operation and under construction. Section 2 presents a chronological listing of all SALP report ratings for each operating facility. Section 3 presents a chronological listing of all SALP report ratings for each facility under construction. For historical purposes, past construction ratings for facilities that recently have been licensed also are listed in Section 3

  8. Historical data summary of the systematic assessment of licensee performance

    International Nuclear Information System (INIS)

    Allenspach, F.

    1992-02-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following sections: Section 1 presents the most recent SALP report ratings for facilities in operation and under construction. Section 2 presents a chronological listing of all SALP report ratings for each operating facility. Section 3 presents a chronological listing of all SALP report ratings for each facility under construction. For historical purposes, past construction ratings for facilities that recently have been licensed also are listed in Section 3

  9. Historical data summary of the systematic assessment of licensee performance

    International Nuclear Information System (INIS)

    1988-05-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following three sections: Section 1 presents the most recent SALP report ratings for facilities under construction and in operation. Section 2 presents a chronological listing of all SALP report ratings for each operating facility. Section 3 presents a chronological listing of all SALP report ratings for each facility under construction. For historical purposes, past construction SALP ratings for facilities that recently have been licensed also are listed in Section 3

  10. Historical data summary of the Systematic Assessment of Licensee Performance

    International Nuclear Information System (INIS)

    Allenspach, F.; Nease, R.

    1990-02-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following sections: Section 1 presents the most recent SALP report ratings for facilities in operation and under construction. Section 2 presents a chronological listing of all SALP report ratings for each operating facility. Section 3 presents a chronological listing of all SALP report ratings for each facility under construction. For historical purposes, past construction ratings for facilities that recently have been licensed also are listed in Section 3

  11. Historical data summary of the Systematic Assessment of Licensee Performance

    International Nuclear Information System (INIS)

    Ramey-Smith, A.M.

    1987-10-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following three sections: the most recent SALP report ratings for facilities under construction and in operation, a chronological listing of all SALP report ratings for each operating facility, a chronological listing of all SALP report ratings for each facility under construction. For historical purposes, past construction SALP ratings for facilities that recently have been licensed also are listed

  12. Historical data summary of the systematic assessment of licensee performance

    International Nuclear Information System (INIS)

    Allenspach, F.

    1991-02-01

    The Historical Data Summary of the Systematic Assessment of Licensee Performance (SALP) is produced periodically by the US Nuclear Regulatory Commission. This summary provides the results of the assessment for each facility by NRC region and is further divided into the following sections: Section 1 presents the most recent SALP report ratings for facilities in operation and under construction. Section 2 presents a chronological listing of all SALP report ratings for each operating facility. Section 3 presents a chronological listing of all SALP report ratings for each facility under construction. For historical purposes, past construction ratings for facilities that recently have been licensed also are listed in Section 3

  13. Probabilistic performance assessments for evaluations of the Yucca Mountain site

    International Nuclear Information System (INIS)

    Rickertsen, L.D.; Noronha, C.J.

    1992-01-01

    Site suitability evaluations are conducted to determine if a repository system at a particular site will be able to meet the performance objectives for that system. Early evaluations to determine if the Yucca Mountain site is suitable for repository development have been made in the face of large uncertainties in site features and conditions. Because of these large uncertainties, the evaluations of the site have been qualitative in nature, focusing on the presence or absence of particular features or conditions thought to be important to performance, rather than on results of quantitative performance assessments. Such a qualitative approach was used in the recently completed evaluation of the Yucca Mountain site, the Early Site-Suitability Evaluation (ESSE). In spite of the qualitative approach, the ESSE was able to conclude that no disqualifying conditions are likely to be present at the site and that all of the geologic conditions that would qualify the site are likely to be met. At the same time, because of the qualitative nature of the approach used in the ESSE, the precise importance of the identified issues relative to performance could not be determined. Likewise, the importance of the issues relative to one another could not be evaluated, and, other than broad recommendations, specific priorities for future testing could not be set. The authors have conducted quantitative performance assessments for the Yucca Mountain site to address these issues

  14. Quantitative assessment of finger motor performance: Normative data.

    Directory of Open Access Journals (Sweden)

    Alessio Signori

    Full Text Available Finger opposition movements are the basis of many daily living activities and are essential in general for manipulating objects; an engineered glove quantitatively assessing motor performance during sequences of finger opposition movements has been shown to be useful to provide reliable measures of finger motor impairment, even subtle, in subjects affected by neurological diseases. However, the obtained behavioral parameters lack published reference values.To determine mean values for different motor behavioral parameters describing the strategy adopted by healthy people in performing repeated sequences of finger opposition movements, examining associations with gender and age.Normative values for finger motor performance parameters were obtained on a sample of 255 healthy volunteers executing sequences of finger-to-thumb opposition movements, stratified by gender and over a wide range of ages. Touch duration, inter-tapping interval, movement rate, correct sequences (%, movements in advance compared with a metronome (% and inter-hand interval were assessed.Increasing age resulted in decreased movement speed, advance movements with respect to a cue, correctness of sequences, and bimanual coordination. No significant performance differences were found between male and female subjects except for the duration of the finger touch, the interval between two successive touches and their ratio.We report age- and gender-specific normal mean values and ranges for different parameters objectively describing the performance of finger opposition movement sequences, which may serve as useful references for clinicians to identify possible deficits in subjects affected by diseases altering fine hand motor skills.

  15. Thermodynamic performance assessment of wind energy systems: An application

    International Nuclear Information System (INIS)

    Redha, Adel Mohammed; Dincer, Ibrahim; Gadalla, Mohamed

    2011-01-01

    In this paper, the performance of wind energy system is assessed thermodynamically, from resource and technology perspectives. The thermodynamic characteristics of wind through energy and exergy analyses are considered and both energetic and exergetic efficiencies are studied. Wind speed is affected by air temperature and pressure and has a subsequent effect on wind turbine performance based on wind reference temperature and Bernoulli's equation. VESTAS V52 wind turbine is selected for (Sharjah/UAE). Energy and exergy efficiency equations for wind energy systems are further developed for practical applications. The results show that there are noticeable differences between energy and exergy efficiencies and that exergetic efficiency reflects the right/actual performance. Finally, exergy analysis has been proven to be the right tool used in design, simulation, and performance evaluation of all renewable energy systems. -- Highlights: → In this research the performance of wind energy system is assessed thermodynamically, from resource and technology perspectives. → Energy and exergy equations for wind energy systems are further developed for practical applications. → Thermodynamic characteristics of wind turbine systems through energetic and exergetic efficiencies are evaluated from January till March 2010. → Exergy efficiency describes the system irreversibility and the minimum irreversibility exists when the wind speed reaches 11 m/s. → The power production during March was about 17% higher than the month of February and 66% higher than January.

  16. Performance of GPS-devices for environmental exposure assessment.

    Science.gov (United States)

    Beekhuizen, Johan; Kromhout, Hans; Huss, Anke; Vermeulen, Roel

    2013-01-01

    Integration of individual time-location patterns with spatially resolved exposure maps enables a more accurate estimation of personal exposures to environmental pollutants than using estimates at fixed locations. Current global positioning system (GPS) devices can be used to track an individual's location. However, information on GPS-performance in environmental exposure assessment is largely missing. We therefore performed two studies. First, a commute-study, where the commute of 12 individuals was tracked twice, testing GPS-performance for five transport modes and two wearing modes. Second, an urban-tracking study, where one individual was tracked repeatedly through different areas, focused on the effect of building obstruction on GPS-performance. The median error from the true path for walking was 3.7 m, biking 2.9 m, train 4.8 m, bus 4.9 m, and car 3.3 m. Errors were larger in a high-rise commercial area (median error=7.1 m) compared with a low-rise residential area (median error=2.2 m). Thus, GPS-performance largely depends on the transport mode and urban built-up. Although ~85% of all errors were 50 m. Modern GPS-devices are useful tools for environmental exposure assessment, but large GPS-errors might affect estimates of exposures with high spatial variability.

  17. A method for performance assessment of medical radioisotope equipment

    International Nuclear Information System (INIS)

    Kerin, T.; Slavtchev, Ath.; Nedeltchev, M.; Kjurktchiev, T.

    1984-01-01

    A variety of tests and procedures exist for the performance assessment of radioisotope diagnostic equipment. The complex performance index which has been introduced to date is based on an heuristic approach. The present work tries to interconnect algorithmically the most important factors as the influence of the measurement geometry, the statistic peculiarities for lower activities and the information loss at high count rates. All this is reflected in a criterion which integrates the spatial resolution, the effective detector's field of vision, the radionuclide's sensitivity, the background count rate and the effective dead-time of the system under investigation. (Auth.)

  18. Assessing performance of flaw characterization methods through uncertainty propagation

    Science.gov (United States)

    Miorelli, R.; Le Bourdais, F.; Artusi, X.

    2018-04-01

    In this work, we assess the inversion performance in terms of crack characterization and localization based on synthetic signals associated to ultrasonic and eddy current physics. More precisely, two different standard iterative inversion algorithms are used to minimize the discrepancy between measurements (i.e., the tested data) and simulations. Furthermore, in order to speed up the computational time and get rid of the computational burden often associated to iterative inversion algorithms, we replace the standard forward solver by a suitable metamodel fit on a database built offline. In a second step, we assess the inversion performance by adding uncertainties on a subset of the database parameters and then, through the metamodel, we propagate these uncertainties within the inversion procedure. The fast propagation of uncertainties enables efficiently evaluating the impact due to the lack of knowledge on some parameters employed to describe the inspection scenarios, which is a situation commonly encountered in the industrial NDE context.

  19. Total System Performance Assessment-License Application Methods and Approach

    Energy Technology Data Exchange (ETDEWEB)

    J. McNeish

    2002-09-13

    ''Total System Performance Assessment-License Application (TSPA-LA) Methods and Approach'' provides the top-level method and approach for conducting the TSPA-LA model development and analyses. The method and approach is responsive to the criteria set forth in Total System Performance Assessment Integration (TSPAI) Key Technical Issue (KTI) agreements, the ''Yucca Mountain Review Plan'' (CNWRA 2002 [158449]), and 10 CFR Part 63. This introductory section provides an overview of the TSPA-LA, the projected TSPA-LA documentation structure, and the goals of the document. It also provides a brief discussion of the regulatory framework, the approach to risk management of the development and analysis of the model, and the overall organization of the document. The section closes with some important conventions that are utilized in this document.

  20. Total System Performance Assessment - License Application Methods and Approach

    International Nuclear Information System (INIS)

    McNeish, J.

    2003-01-01

    ''Total System Performance Assessment-License Application (TSPA-LA) Methods and Approach'' provides the top-level method and approach for conducting the TSPA-LA model development and analyses. The method and approach is responsive to the criteria set forth in Total System Performance Assessment Integration (TSPAI) Key Technical Issues (KTIs) identified in agreements with the U.S. Nuclear Regulatory Commission, the ''Yucca Mountain Review Plan'' (YMRP), ''Final Report'' (NRC 2003 [163274]), and the NRC final rule 10 CFR Part 63 (NRC 2002 [156605]). This introductory section provides an overview of the TSPA-LA, the projected TSPA-LA documentation structure, and the goals of the document. It also provides a brief discussion of the regulatory framework, the approach to risk management of the development and analysis of the model, and the overall organization of the document. The section closes with some important conventions that are used in this document

  1. Influence choreographic readiness to gymnasts final assessment of performance skills

    Directory of Open Access Journals (Sweden)

    O.A. Omelichyk-Ziurkalova

    2014-10-01

    Full Text Available Purpose : to provide a quantitative assessment and expert choreographic preparedness gymnasts. Material : the study involved eight gymnasts competition finalists in the floor exercise - female members of the Ukrainian national team in gymnastics. Results : the quantitative indicators of acrobatic and dance elements to determine the baseline assessment. Defined methods complications composition on the floor exercise by reducing the number of acrobatic lines and diagonals and increase the number of gymnastic elements. The theoretical performance of the composite sequence is improved structure and increases the difficulty of the exercise. Conclusions : in the process of composition complications need to pay more attention to the technique of performing gymnastic elements. In improving exercise choreography element replace (in some cases acrobatic element. Based on the results is planned future direction of research in order to improve the training process in gymnastics.

  2. SKI SITE-94, deep repository performance assessment project, summary

    International Nuclear Information System (INIS)

    1999-01-01

    SITE-94 is a comprehensive performance assessment exercise for a hypothetical repository for spent nuclear fuel at a real site in Sweden. SITE-94 was carried out to develop the capability and tools to enable Swedish Nuclear Power Inspectorate (SKI) to review fully the proposals for a deep repository which are expected to be made by the Swedish Nuclear Fuel and Waste Management Company, SKB (the implementor). Sweden is one of the leading countries in the research and development of geological disposal of radioactive waste. The developed methodology for performance assessment has attracted interests from other countries. The Summary of the main report of the SITE-94 project is translated here into Japanese to allow to make the information on the methodology and the related issues available among Japanese concerned. (author)

  3. Sensitivity and uncertainty analyses for performance assessment modeling

    International Nuclear Information System (INIS)

    Doctor, P.G.

    1988-08-01

    Sensitivity and uncertainty analyses methods for computer models are being applied in performance assessment modeling in the geologic high level radioactive waste repository program. The models used in performance assessment tend to be complex physical/chemical models with large numbers of input variables. There are two basic approaches to sensitivity and uncertainty analyses: deterministic and statistical. The deterministic approach to sensitivity analysis involves numerical calculation or employs the adjoint form of a partial differential equation to compute partial derivatives; the uncertainty analysis is based on Taylor series expansions of the input variables propagated through the model to compute means and variances of the output variable. The statistical approach to sensitivity analysis involves a response surface approximation to the model with the sensitivity coefficients calculated from the response surface parameters; the uncertainty analysis is based on simulation. The methods each have strengths and weaknesses. 44 refs

  4. Empirical Assessment on Financial Regulations and Banking Sector Performance

    Directory of Open Access Journals (Sweden)

    Igbinosa S.

    2017-09-01

    Full Text Available This study examines financial regulation and banking sector performance in Nigeria. Specifically, the study determines the impact of reforms on banking sector performance and also assesses the nexus between capital adequacy and banking sector performance. Time series data for the period 1993 to 2014 was used. As an analytical tool, the study uses unit root test to determine the stationary state of the variables. We also employed the Johansson co-integration and error correction model (ECM statistical techniques to establish both short-run and long-run dynamic relationships between the endogenous and exogenous variables. The empirical findings indicate that financial regulation significantly impacts the banking sector performance while financial regulation has both short-run and long-run dynamic relationships with the banking sector performance in Nigeria. It was found that the four-period lag of capital adequacy negatively affects banking sector performance and is not statistically significant. The paper suggests that the Central Bank of Nigeria (CBN should continually make public the impacts that the various financial regulations and reforms have on the performance of Nigerian banks. Majority of the policies on financial regulation by the apex bank (CBN need to be long-run which can enable confidence of stakeholders, shareholders and the general public in the Nigerian banking industry when critically evaluated.

  5. SCHRAADLO: Assessment of SCHRAADLO-T performance for S scenario

    International Nuclear Information System (INIS)

    Horyna, J.

    1996-01-01

    The model SCHRAADLO has been developed to assess the environmental impact of nuclear facilities. It is a dynamic compartmental model. The model is driven by daily air concentration and daily precipitation rate. The output are time dependent concentrations in soil, different types of meat and plants, milk and whole body. There are not included aquatic and seminatural food chains. Calculations of contamination of fungi have been performed separately. 8 figs, 2 tabs

  6. Historical data summary of the Systematic Assessment of Licensee Performance

    International Nuclear Information System (INIS)

    Johnson, M.R.; Waterman, D.K.

    1987-04-01

    This report presents a history of Systematic Assessment of Licensee Performance (SALP) ratings for nuclear power plant facilities in operation and under construction. The SALP results are listed by NRC region in three sections: the most recent report, operating facilities, and facilities under construction. The historical data summary report has been prepared by the NRC Office of Inspection and Enforcement (IE). Information contained in this report has been updated to include those published SALP reports received before March 13, 1987

  7. Historical data summary of the systematic assessment of licensee performance

    International Nuclear Information System (INIS)

    1986-10-01

    This report presents a history of Systematic Assessment of Licensee Performance (SALP) ratings for nuclear power plant facilities in operation and under construction. The SALP results are listed by NRC region in three sections: the most recent report, operating facilities, and facilities under construction. The historical data summary report has been prepared by the NRC Office of Inspection and Enforcement (IE). Information contained in this report has been updated to include those published SALP reports received before September 16, 1986

  8. SELECTED REQUIREMENTS OF INTEGRATED MANAGEMENT SYSTEMS BASED ON PAS 99 SPECIFICATION

    Directory of Open Access Journals (Sweden)

    Paweł Nowicki

    2013-03-01

    Full Text Available The aim this research was to analyze the ways of integration of management systems in food sector. The study involved the documentation, audits, corrective and preventive actions and management's review phases described in the specification PAS 99, which is one of common elements of integrated management systems. Four organizations were selected for the study. The organizations had introduced and certified at least two standardized management systems. It was assumed that the investigated organizations should have implemented the HACCP system. Studies were conducted as a case study. The employees responsible for the functioning of management systems were interviewed in all four organizations. The study was conducted in the form of in-depth interviews based on pre-prepared script. The scenario was developed based on the PAS 99 guideline. The process of integration of management systems implemented in the studied companies reveals the full compliance of an integrated management system with PASS 99 in the policy area.

  9. Using Performance in Multiple Simulated Scenarios to Assess Bronchoscopy Skills

    DEFF Research Database (Denmark)

    Konge, Lars; Arendrup, Henrik; Buchwald, Christian von

    2011-01-01

    using a standardized scoring form. Methods: The test was administered on a virtual reality bronchoscopy simulator to a total of 42 test subjects (14 senior consultants, 14 trainees and 14 medical students). The inter-rater reliability of the test procedure was explored according to examination of test......Background: International guidelines suggest that trainees should perform at least 100 flexible bronchoscopies in a supervised setting, but this number is not evidence based. An objective assessment method could provide educational feedback to trainees and help supervisors decide when basic...... competency is established. No former assessment instrument has been able to distinguish between trainees and experts. Objectives: The aim of this study was to explore the validity and reliability of a new assessment procedure relating to testing operators across multiple tasks with increasing difficulty...

  10. Assessing reservoir performance risk in CO2 storage projects

    International Nuclear Information System (INIS)

    Bowden, A.R.; Rigg, A.

    2005-01-01

    One of the main issues for researchers involved with geological storage of carbon dioxide (CO 2 ) has been the development of a proper methodology to assess and compare alternative CO 2 injection projects on the basis of risk. Consideration needs to be given to technical aspects, such as the risk of leakage and the effectiveness of the intended reservoir, as well as less tangible aspects such as the value and safety of geological storage of CO 2 , and potential impacts on the community and environment. The Geological Disposal of Carbon Dioxide (GEODISC), was a research program of the Australian Petroleum Cooperative Research Centre which identified 56 potential environmentally sustainable sites for CO 2 injection (ESSCIs) within Australia. Several studies were carried out, involving detailed evaluation of the suitability of 4 selected sites, including Dongara, Petrel, Gippsland and Carnarvon. The GEODISC program included a risk assessment research module which required a complete and quantified risk assessment of CO 2 injection as a storage option. Primary goals were to assess the risk of leakage, to assess the effectiveness of the intended reservoir, and to assess negative consequences to facilitate comparison of alternative sites. This paper discussed the background and risk assessment model. Key performance indicators (KPIs) were also developed to address the purpose of risk assessment. It was concluded that the RISQUE method is an appropriate approach and that potential injection projects can be measured against six KPIs including containment; effectiveness; self-funding potential; wider community benefits; community safety and community amenity. 6 refs., 3 tabs., 3 figs

  11. Characterisation of radionuclide migration and plant uptake for performance assessment

    International Nuclear Information System (INIS)

    Mathias, S. A.; Ireson, A. M.; Butler, A. P.; Jackson, B. M.; Wheater, H. S.

    2008-01-01

    Unsaturated vegetated soils are an important component in performance assessment models used to quantify risks associated with deep engineered repositories for underground radioactive waste disposal. Therefore, experimental studies, funded by Nirex over nearly 20 years, have been undertaken at Imperial College to study the transfer of radionuclides (Cl-36, I-129, Tc-99) from contaminated groundwater into crops. In parallel to this has been a modelling programme to aid interpretation of the experimental data, obtain parameter values characterising transport in soil and plant uptake and provide new representations of near-surface processes for performance assessment. A particular challenge in achieving these objectives is that the scale of the experimental work (typically ≤1 m) is much smaller than that required in performance assessment. In this paper, a new methodology is developed for up-scaling model results obtained at the experimental scale for use in catchment scale models. The method is based on characterising soil heterogeneity using soil texture. This has the advantage of allowing hydrological and radionuclide transport parameters to be correlated in a consistent manner. An initial investigation into the calculation of effective (i.e. up-scaled) hydrological and transport parameters has been undertaken and shows the results to be potentially highly (and non-linearly) sensitive to soil properties. Consequently, they have important implications for future site characterisation programmes supporting a proposed underground waste repository. (authors)

  12. Risk-adjusted payment and performance assessment for primary care.

    Science.gov (United States)

    Ash, Arlene S; Ellis, Randall P

    2012-08-01

    Many wish to change incentives for primary care practices through bundled population-based payments and substantial performance feedback and bonus payments. Recognizing patient differences in costs and outcomes is crucial, but customized risk adjustment for such purposes is underdeveloped. Using MarketScan's claims-based data on 17.4 million commercially insured lives, we modeled bundled payment to support expected primary care activity levels (PCAL) and 9 patient outcomes for performance assessment. We evaluated models using 457,000 people assigned to 436 primary care physician panels, and among 13,000 people in a distinct multipayer medical home implementation with commercially insured, Medicare, and Medicaid patients. Each outcome is separately predicted from age, sex, and diagnoses. We define the PCAL outcome as a subset of all costs that proxies the bundled payment needed for comprehensive primary care. Other expected outcomes are used to establish targets against which actual performance can be fairly judged. We evaluate model performance using R(2)'s at patient and practice levels, and within policy-relevant subgroups. The PCAL model explains 67% of variation in its outcome, performing well across diverse patient ages, payers, plan types, and provider specialties; it explains 72% of practice-level variation. In 9 performance measures, the outcome-specific models explain 17%-86% of variation at the practice level, often substantially outperforming a generic score like the one used for full capitation payments in Medicare: for example, with grouped R(2)'s of 47% versus 5% for predicting "prescriptions for antibiotics of concern." Existing data can support the risk-adjusted bundled payment calculations and performance assessments needed to encourage desired transformations in primary care.

  13. [Parental alienation syndrome (PAS): unknown in medical settings, endemic in courts].

    Science.gov (United States)

    Pignotti, Maria Serenella

    2013-02-01

    A purposed syndrome of so-called parental alienation (PAS), unsupported by any evidence-based data, unknown in medical settings, unquoted in medical books, absent in DSM and ICD, never demonstrated by controlled studies published in high scientific level journals, is rampant in Courts where it can lead to loose parental custody. During a divorce trial, almost always the mothers and the children, become joint in a sort of folie au deux, in a denigration campaign of ex-husband/father. From a review on this issue it seems evident its theoretical roots lie on a theory that justify gender violence and children sexual abuse. The bias that both of them are layers and that he children have not autonomy block their possibility of any defence in front of a Court. In severe cases, PAS becomes a new and efficient tool of intra-familiar violence. The treatment of severe cases is to stop any contact between mother and children. The resort to PAS in Courts must be strongly rejected.

  14. Some considerations for validation of repository performance assessment models

    International Nuclear Information System (INIS)

    Eisenberg, N.

    1991-01-01

    Validation is an important aspect of the regulatory uses of performance assessment. A substantial body of literature exists indicating the manner in which validation of models is usually pursued. Because performance models for a nuclear waste repository cannot be tested over the long time periods for which the model must make predictions, the usual avenue for model validation is precluded. Further impediments to model validation include a lack of fundamental scientific theory to describe important aspects of repository performance and an inability to easily deduce the complex, intricate structures characteristic of a natural system. A successful strategy for validation must attempt to resolve these difficulties in a direct fashion. Although some procedural aspects will be important, the main reliance of validation should be on scientific substance and logical rigor. The level of validation needed will be mandated, in part, by the uses to which these models are put, rather than by the ideal of validation of a scientific theory. Because of the importance of the validation of performance assessment models, the NRC staff has engaged in a program of research and international cooperation to seek progress in this important area. 2 figs., 16 refs

  15. Preliminary parametric performance assessment of potential final waste forms for alpha low-level waste at the Idaho National Engineering Laboratory. Revision 1

    International Nuclear Information System (INIS)

    Smith, T.H.; Sussman, M.E.; Myers, J.; Djordjevic, S.M.; DeBiase, T.A.; Goodrich, M.T.; DeWitt, D.

    1995-08-01

    This report presents a preliminary parametric performance assessment (PA) of potential waste disposal systems for alpha-contaminated, mixed, low-level waste (ALLW) currently stored at the Transuranic Storage Area of INEL. The ALLW, which contains from 10 to 100 nCi/g of transuranic (TRU) radionuclides, is awaiting treatment and disposal. The purpose of this study was to examine the effects of several parameters on the radiological-confinement performance of potential disposal systems for the ALLW. The principal emphasis was on the performance of final waste forms (FWFs). Three categories of FWF (cement, glass, and ceramic) were addressed by evaluating the performance of two limiting FWFs for each category. Performance at five conceptual disposal sites was evaluated to illustrate the effects of site characteristics on the performance of the total disposal system. Other parameters investigated for effects on receptor dose included inventory assumptions, TRU radionuclide concentration, FWF fracture, disposal depth, water infiltration rates, subsurface-transport modeling assumptions, receptor well location, intrusion scenario assumptions, and the absence of waste immobilization. These and other factors were varied singly and in some combinations. The results indicate that compliance of the treated and disposed ALLW with the performance objectives depends on the assumptions made, as well as on the FWF and the disposal site. Some combinations result in compliance, while others do not. The implications of these results for decision making relative to treatment and disposal of the INEL ALLW are discussed. The report compares the degree of conservatism in this preliminary parametric PA against that in four other PAs and one risk assessment. All of the assessments addressed the same disposal site, but different wastes. The report also presents a qualitative evaluation of the uncertainties in the PA and makes recommendations for further study

  16. Geotechnical Issues in Total System Performance Assessments of Yucca Mountain

    International Nuclear Information System (INIS)

    HO, CLIFFORD K.; HOUSEWORTH, JIM; WILSON, MICHAEL L.

    1999-01-01

    A Total System Performance Assessment (TSPA) of Yucca Mountain consists of integrated sub-models and analyses of natural and engineered systems. Examples of subsystem models include unsaturated-zone flow and transport, seepage into drifts, coupled thermal hydrologic processes, transport through the engineered barrier system, and saturated-zone flow and transport. The TSPA evaluates the interaction of important processes among these subsystems, and it determines the impact of these processes on the overall performance measures (e.g., dose rate to humans). This paper summarizes the evaluation, abstraction, and combination of these subsystem models in a TSPA calculation, and it provides background on the individual TSPA subsystem components that are most directly impacted by geotechnical issues. The potential impact that geologic features, events, and processes have on the overall performance is presented, and an evaluation of the sensitivity of TSPA calculations to these issues is also provided

  17. Individual Performance: From Common Source Bias to Institutionalized Assessment

    DEFF Research Database (Denmark)

    Andersen, Lotte Bøgh; Heinesen, Eskil; Pedersen, Lene Holm

    2016-01-01

    theory and the sociology of professions. Empirically, we ask whether different measures of individual performance produce different results. The investigated performance measures vary with regard to risk of common data source bias, standardization of assessment criteria, and external verification...... dimension for the same teachers: the teachers' self-reported contributions to students' academic skills, the students' marks for the year's work given by the teacher, marks in oral exams with one external examiner and the teacher, and marks in written exams with at least one external examiner....... The associations are systematically stronger when the performance measure comes from the same data source as the explanatory variables, but when separate data sources are used and the measurement scale is institutionalized, the level of external verification does not matter much. Based on institutional theory...

  18. Survey and review of near-field performance assessment

    International Nuclear Information System (INIS)

    Apted, M.J.

    1993-01-01

    Chemical reactions control the performance, stability, and rate of degradation of natural and engineered barriers to waste repositories of the near field. Chemical processes are overviewed in this context. Temperature, and associated temperature gradients, are also important parameters in near-field performance assessment. The mechanical conditions of the near-field rock will be perturbed by construction of the underground repository. Mechanical analysis in the near field is further complicated by the introduction of HLW canisters and associated engineered barrier materials. Hydrological processes important to near-field performance include those associated with fluid transport. Considerable discussions and studies have been conducted on the issue of coupling among chemical-thermal-mechanical-hydrological processes; they are overviewed. (R.P.) 2 figs., 2 tabs

  19. Examining the Extremes: High and Low Performance on a Teaching Performance Assessment for Licensure

    Science.gov (United States)

    Sandholtz, Judith Haymore; Shea, Lauren M.

    2015-01-01

    In assessing the teaching practice of preservice teacher candidates, observers, particularly trained observers, will readily identify those who are exceptionally effective or ineffective. The anticipation is that university supervisors and mentor teachers will agree on who demonstrates extraordinary performance for a preservice candidate and who…

  20. Proposed evaluation framework for assessing operator performance with multisensor displays

    Science.gov (United States)

    Foyle, David C.

    1992-01-01

    Despite aggressive work on the development of sensor fusion algorithms and techniques, no formal evaluation procedures have been proposed. Based on existing integration models in the literature, an evaluation framework is developed to assess an operator's ability to use multisensor, or sensor fusion, displays. The proposed evaluation framework for evaluating the operator's ability to use such systems is a normative approach: The operator's performance with the sensor fusion display can be compared to the models' predictions based on the operator's performance when viewing the original sensor displays prior to fusion. This allows for the determination as to when a sensor fusion system leads to: 1) poorer performance than one of the original sensor displays (clearly an undesirable system in which the fused sensor system causes some distortion or interference); 2) better performance than with either single sensor system alone, but at a sub-optimal (compared to the model predictions) level; 3) optimal performance (compared to model predictions); or, 4) super-optimal performance, which may occur if the operator were able to use some highly diagnostic 'emergent features' in the sensor fusion display, which were unavailable in the original sensor displays. An experiment demonstrating the usefulness of the proposed evaluation framework is discussed.

  1. Twelve tips for assessing surgical performance and use of technical assessment scales

    DEFF Research Database (Denmark)

    Strandbygaard, Jeanett; Scheele, Fedde; Sørensen, Jette Led

    2017-01-01

    Using validated assessment scales for technical competence can help structure and standardize assessment and feedback for both the trainee and the supervisor and thereby avoid bias and drive learning. Correct assessment of operative skills can establish learning curves and allow adequate monitoring....... However, the assessment of surgical performance is not an easy task, since it includes many proxy parameters, which are hard to measure. Although numerous technical assessment scales exist, both within laparoscopic and open surgery, the validity evidence is often sparse, and this can raise doubts about...... reliability and educational outcome. Furthermore, the implementation of technical assessment scales varies due to several obstacles and doubts about accurate use. In this 12-tips article, we aim to give the readers a critical and useful appraisal of some of the common questions and misunderstandings regarding...

  2. Pediatric Eating Assessment Tool-10 as an indicator to predict aspiration in children with esophageal atresia.

    Science.gov (United States)

    Soyer, Tutku; Yalcin, Sule; Arslan, Selen Serel; Demir, Numan; Tanyel, Feridun Cahit

    2017-10-01

    Airway aspiration is a common problem in children with esophageal atresia (EA). Pediatric Eating Assessment Tool-10 (pEAT-10) is a self-administered questionnaire to evaluate dysphagia symptoms in children. A prospective study was performed to evaluate the validity of pEAT-10 to predict aspiration in children with EA. Patients with EA were evaluated for age, sex, type of atresia, presence of associated anomalies, type of esophageal repair, time of definitive treatment, and the beginning of oral feeding. Penetration-aspiration score (PAS) was evaluated with videofluoroscopy (VFS) and parents were surveyed for pEAT-10, dysphagia score (DS) and functional oral intake scale (FOIS). PAS scores greater than 7 were considered as risk of aspiration. EAT-10 values greater than 3 were assessed as abnormal. Higher DS scores shows dysphagia whereas higher FOIS shows better feeding abilities. Forty patients were included. Children with PAS greater than 7 were assessed as PAS+ group, and scores less than 7 were constituted as PAS- group. Demographic features and results of surgical treatments showed no difference between groups (p>0.05). The median values of PAS, pEAT-10 and DS scores were significantly higher in PAS+ group when compared to PAS- group (p<0.05). The sensitivity and specificity of pEAT-10 to predict aspiration were 88% and 77%, and the positive and negative predictive values were 22% and 11%, respectively. Type-C cases had better pEAT-10 and FOIS scores with respect to type-A cases, and both scores were statistically more reliable in primary repair than delayed repair (p<0.05). Among the postoperative complications, only leakage had impact on DS, pEAT-10, PAS and FOIS scores (p<0.05). The pEAT-10 is a valid, simple and reliable tool to predict aspiration in children. Patients with higher pEAT-10 scores should undergo detailed evaluation of deglutitive functions and assessment of risks of aspiration to improve safer feeding strategies. Level II (Development of

  3. Beginning science teachers' performances: Assessment in times of reform

    Science.gov (United States)

    Budzinsky, Fie K.

    2000-10-01

    The current reform in science education and the research on effective teaching and student learning have reinforced the importance of teacher competency. To better measure performances in the teaching of science, performance assessment has been added to Connecticut's licensure process for beginning science teachers. Teaching portfolios are used to document teaching and learning over time. Portfolios, however, are not without problems. One of the major concerns with the portfolio assessment process is its subjectivity. Assessors may not have opportunities to ask clarifying or follow-up questions to enhance the interpretation of a teacher's performance. In addition, portfolios often contain components based on self-documentation, which are subjective. Furthermore, the use of portfolios raises test equity issues. These concerns present challenges for persons in charge of establishing the validity of a portfolio-based licensure process. In high-stakes decision processes, such as teaching licensure, the validity of the assessment instruments must be studied. The primary purpose of this study was to explore the criterion-related validity of the Connecticut State Department of Education's Beginning Science Teaching Portfolio by comparing the interpretations of performances from science teaching portfolios to those derived from another assessment method, the Expert Science Teaching Educational and Evaluation Model, (ESTEEM). The analysis of correlations between the Beginning Science Teaching Portfolio and ESTEEM instrument scores was the primary method for establishing support for validity. The results indicated moderate correlations between all Beginning Science Teaching Portfolio and ESTEEM category and total variables. Multiple regression was used to examine whether differences existed in beginning science teachers' performances based on gender, poverty group, school level, and science discipline taught. None of these variables significantly contributed to the

  4. Hanford immobilized low-activity tank waste performance assessment

    International Nuclear Information System (INIS)

    Mann, F.M.

    1998-01-01

    The Hanford Immobilized Low-Activity Tank Waste Performance Assessment examines the long-term environmental and human health effects associated with the planned disposal of the vitrified low-level fraction of waste presently contained in Hanford Site tanks. The tank waste is the by-product of separating special nuclear materials from irradiated nuclear fuels over the past 50 years. This waste has been stored in underground single and double-shell tanks. The tank waste is to be retrieved, separated into low and high-activity fractions, and then immobilized by private vendors. The US Department of Energy (DOE) will receive the vitrified waste from private vendors and plans to dispose of the low-activity fraction in the Hanford Site 200 East Area. The high-level fraction will be stored at Hanford until a national repository is approved. This report provides the site-specific long-term environmental information needed by the DOE to issue a Disposal Authorization Statement that would allow the modification of the four existing concrete disposal vaults to provide better access for emplacement of the immobilized low-activity waste (ILAW) containers; filling of the modified vaults with the approximately 5,000 ILAW containers and filler material with the intent to dispose of the containers; construction of the first set of next-generation disposal facilities. The performance assessment activity will continue beyond this assessment. The activity will collect additional data on the geotechnical features of the disposal sites, the disposal facility design and construction, and the long-term performance of the waste. Better estimates of long-term performance will be produced and reviewed on a regular basis. Performance assessments supporting closure of filled facilities will be issued seeking approval of those actions necessary to conclude active disposal facility operations. This report also analyzes the long-term performance of the currently planned disposal system as a basis

  5. Hanford immobilized low-activity tank waste performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mann, F.M.

    1998-03-26

    The Hanford Immobilized Low-Activity Tank Waste Performance Assessment examines the long-term environmental and human health effects associated with the planned disposal of the vitrified low-level fraction of waste presently contained in Hanford Site tanks. The tank waste is the by-product of separating special nuclear materials from irradiated nuclear fuels over the past 50 years. This waste has been stored in underground single and double-shell tanks. The tank waste is to be retrieved, separated into low and high-activity fractions, and then immobilized by private vendors. The US Department of Energy (DOE) will receive the vitrified waste from private vendors and plans to dispose of the low-activity fraction in the Hanford Site 200 East Area. The high-level fraction will be stored at Hanford until a national repository is approved. This report provides the site-specific long-term environmental information needed by the DOE to issue a Disposal Authorization Statement that would allow the modification of the four existing concrete disposal vaults to provide better access for emplacement of the immobilized low-activity waste (ILAW) containers; filling of the modified vaults with the approximately 5,000 ILAW containers and filler material with the intent to dispose of the containers; construction of the first set of next-generation disposal facilities. The performance assessment activity will continue beyond this assessment. The activity will collect additional data on the geotechnical features of the disposal sites, the disposal facility design and construction, and the long-term performance of the waste. Better estimates of long-term performance will be produced and reviewed on a regular basis. Performance assessments supporting closure of filled facilities will be issued seeking approval of those actions necessary to conclude active disposal facility operations. This report also analyzes the long-term performance of the currently planned disposal system as a basis

  6. PERFORMANCE ASSESSMENT AND GEOMETRIC CALIBRATION OF RESOURCESAT-2

    Directory of Open Access Journals (Sweden)

    P. V. Radhadevi

    2016-06-01

    Full Text Available Resourcesat-2 (RS-2 has successfully completed five years of operations in its orbit. This satellite has multi-resolution and multi-spectral capabilities in a single platform. A continuous and autonomous co-registration, geo-location and radiometric calibration of image data from different sensors with widely varying view angles and resolution was one of the challenges of RS-2 data processing. On-orbit geometric performance of RS-2 sensors has been widely assessed and calibrated during the initial phase operations. Since then, as an ongoing activity, various geometric performance data are being generated periodically. This is performed with sites of dense ground control points (GCPs. These parameters are correlated to the direct geo-location accuracy of the RS-2 sensors and are monitored and validated to maintain the performance. This paper brings out the geometric accuracy assessment, calibration and validation done for about 500 datasets of RS-2. The objectives of this study are to ensure the best absolute and relative location accuracy of different cameras, location performance with payload steering and co-registration of multiple bands. This is done using a viewing geometry model, given ephemeris and attitude data, precise camera geometry and datum transformation. In the model, the forward and reverse transformations between the coordinate systems associated with the focal plane, payload, body, orbit and ground are rigorously and explicitly defined. System level tests using comparisons to ground check points have validated the operational geo-location accuracy performance and the stability of the calibration parameters.

  7. Post-closure performance assessment treatment of the biosphere

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, M A [UK Nirex Ltd., Harwell, Oxfordshire (United Kingdom); Egan, M J [AEA Technology, Risley, Cheshire (United Kingdom); Thorne, M C [Electrowatt, Horsham, Sussex (United Kingdom); Williams, J A [AEA Technology, Risley, Cheshire (United Kingdom)

    1996-07-01

    The Nirex strategy for radioactive waste disposal is based on a system of engineered and natural barriers, providing long-term isolation of the waste from those parts of the environment that are in contact with or readily available for use by humans (i.e. the biosphere). Even so, there remains the possibility that, on a timescale of thousands to tens of thousands of years, small quantities of poorly-sorbed, long-lived radionuclides may be released from the engineered disposal system, ultimately to emerge into the biosphere. Biosphere models are used in post-closure performance assessments to quantify the competing effects of dilution and accumulation processes on radionuclide concentrations in the accessible environment. Understanding biosphere processes and their time dependence is necessary not only to determine the radiological impact of possible future releases, but also to characterise the dynamics of transport in groundwater and the location, duration and extent of any such releases. Nirex is developing a new biosphere model for use in post-closure radiological assessments for the proposed Sellafield repository. A compartment modelling approach has been adopted, as in studies performed previously, but the system will be dynamic, allowing changes with time in both the properties of compartments and the transfers between compartments. The transport model considers both mass transport within the biosphere and the migration of radionuclides, thereby ensuring that a self-consistent description of the biosphere, in a spatially-extensive domain is maintained. The above approach is designed to link the assessment models used by the Nirex assessment team more closely into the Nirex biosphere research programme than has hitherto been possible with time-invariant assessment models. (author)

  8. Post-closure performance assessment treatment of the biosphere

    International Nuclear Information System (INIS)

    Broderick, M.A.; Egan, M.J.; Thorne, M.C.; Williams, J.A.

    1996-01-01

    The Nirex strategy for radioactive waste disposal is based on a system of engineered and natural barriers, providing long-term isolation of the waste from those parts of the environment that are in contact with or readily available for use by humans (i.e. the biosphere). Even so, there remains the possibility that, on a timescale of thousands to tens of thousands of years, small quantities of poorly-sorbed, long-lived radionuclides may be released from the engineered disposal system, ultimately to emerge into the biosphere. Biosphere models are used in post-closure performance assessments to quantify the competing effects of dilution and accumulation processes on radionuclide concentrations in the accessible environment. Understanding biosphere processes and their time dependence is necessary not only to determine the radiological impact of possible future releases, but also to characterise the dynamics of transport in groundwater and the location, duration and extent of any such releases. Nirex is developing a new biosphere model for use in post-closure radiological assessments for the proposed Sellafield repository. A compartment modelling approach has been adopted, as in studies performed previously, but the system will be dynamic, allowing changes with time in both the properties of compartments and the transfers between compartments. The transport model considers both mass transport within the biosphere and the migration of radionuclides, thereby ensuring that a self-consistent description of the biosphere, in a spatially-extensive domain is maintained. The above approach is designed to link the assessment models used by the Nirex assessment team more closely into the Nirex biosphere research programme than has hitherto been possible with time-invariant assessment models. (author)

  9. Comments on SKB's SFL 3-5 preliminary performance assessment

    International Nuclear Information System (INIS)

    Wilmot, R.D.; Crawford, M.B.

    2000-01-01

    Recently introduced regulations in Sweden have established an individual risk criterion ( -6 per year) for the long-term performance of repositories for the disposal of radioactive wastes. SKB has not focused its assessment of SFL 3-5 on demonstrating compliance with this regulation. Instead, SKB has calculated individual dose and provided a comparison with an annual individual dose of 14 iSv (derived from the risk criteria using the ICRP's dose-risk conversion factor of 0.073 per Sv). The justification of this approach is that probabilities do not need to be determined if doses are less than the dose equivalent to the risk criterion. However, there is insufficient information regarding uncertainty provided in the documentation of the SFL 3-5 assessment to determine whether this approach is reasonable. SKB's parallel assessment of a repository for spent fuel using the KBS-3 concept (SR 97) accounts for uncertainty by specifying a 'reasonable' and a 'pessimistic' value for uncertain parameters in the assessment calculations. Although there are problems with the way probabilities have been assigned to these values, this approach does indicate where there are significant uncertainties. The SFL 3-5 PA does not include a structured approach to defining uncertainty, although a number of assumptions and parameter values are stated to be conservative. As a preliminary assessment, there is insufficient information to identify key uncertainties or sensitivities, or to determine where further work should be focused. Any assessment requires the use of expert judgement to determine how the assessment is conducted, what modelling approach to use, what features, events and processes (FEPs) could potentially affect the disposal system, which FEPs should be included in the conceptual models, and which scenarios should be assessed. Judgements are also required in determining how to parameterize the models, and this may extend to formal expert elicitation for particular parameter

  10. A Thermographic Measurement Approach to Assess Supercapacitor Electrical Performances

    Directory of Open Access Journals (Sweden)

    Stanislaw Galla

    2017-12-01

    Full Text Available This paper describes a proposal for the qualitative assessment of condition of supercapacitors based on the conducted thermographic measurements. The presented measurement stand was accompanied by the concept of methodology of performing tests. Necessary conditions, which were needed to minimize the influence of disturbing factors on the performance of thermal imaging measurements, were also indicated. Mentioned factors resulted from both: the hardware limitations and from the necessity to prepare samples. The algorithm that was used to determine the basic parameters for assessment has been presented. The article suggests to use additional factors that may facilitate the analysis of obtained results. Measuring the usefulness of the proposed methodology was tested on commercial samples of supercapacitors. All of the tests were taken in conjunction with the classical methods based on capacitance (C and equivalent series resistance (ESR measurements, which were also presented in the paper. Selected results presenting the observed changes occurring in both: basic parameters of supercapacitors and accompanying fluctuations of thermal fields, along with analysis, were shown. The observed limitations of the proposed assessment method and the suggestions for its development were also described.

  11. A multimodal assessment of driving performance in HIV infection.

    Science.gov (United States)

    Marcotte, T D; Wolfson, T; Rosenthal, T J; Heaton, R K; Gonzalez, R; Ellis, R J; Grant, I

    2004-10-26

    To examine if HIV-seropositive (HIV+) individuals are at risk for impaired driving. Sixty licensed drivers (40 HIV+, 20 HIV-) completed a neuropsychological (NP) test battery and driving assessments. Eleven HIV+ subjects were NP-impaired. Driving-related skills were assessed using 1) two driving simulations (examining accident avoidance and navigational abilities), 2) the Useful Field of View (UFOV) test, and 3) an on-road evaluation. HIV+ NP-impaired subjects had greater difficulty than cognitively intact subjects on all driving measures, whereas the HIV- and HIV+ NP-normal groups performed similarly. On the UFOV, the HIV+ NP-impaired group had worse performance on Visual Processing and Divided Attention tasks but not in overall risk classification. They also had a higher number of simulator accidents (1.3 vs 2.0; p = 0.03), were less efficient at completing the navigation task (3.2 vs 9.2 blocks; p = 0.001), and were more likely to fail the on-road evaluation (6 vs 36%; p = 0.02). Impairment in Executive Functioning was the strongest NP predictor of failing the on-road drive test. NP performance and both simulations independently contributed to a model predicting 48% of the variance in on-road performance. HIV+ NP-impaired individuals are at increased risk for on-road driving impairments, whereas HIV+ individuals with normal cognition are not at a significantly higher risk than HIV- subjects. Executive Functioning is most strongly associated with impaired on-road performance. Cognitive and simulator testing may each provide data in identifying driving-impaired individuals.

  12. Predicting work Performance through selection interview ratings and Psychological assessment

    Directory of Open Access Journals (Sweden)

    Liziwe Nzama

    2008-11-01

    Full Text Available The aim of the study was to establish whether selection interviews used in conjunction with psychological assessments of personality traits and cognitive functioning contribute to predicting work performance. The sample consisted of 102 managers who were appointed recently in a retail organisation. The independent variables were selection interview ratings obtained on the basis of structured competency-based interview schedules by interviewing panels, fve broad dimensions of personality defned by the Five Factor Model as measured by the 15 Factor Questionnaire (15FQ+, and cognitive processing variables (current level of work, potential level of work, and 12 processing competencies measured by the Cognitive Process Profle (CPP. Work performance was measured through annual performance ratings that focused on measurable outputs of performance objectives. Only two predictor variables correlated statistically signifcantly with the criterion variable, namely interview ratings (r = 0.31 and CPP Verbal Abstraction (r = 0.34. Following multiple regression, only these variables contributed signifcantly to predicting work performance, but only 17.8% of the variance of the criterion was accounted for.

  13. Performance assessment of simple and modified cycle turboshaft gas turbines

    Directory of Open Access Journals (Sweden)

    Barinyima Nkoi

    2013-06-01

    Full Text Available This paper focuses on investigations encompassing comparative assessment of gas turbine cycle options. More specifically, investigation was carried out of technical performance of turboshaft engine cycles based on existing simple cycle (SC and its projected modified cycles for civil helicopter application. Technically, thermal efficiency, specific fuel consumption, and power output are of paramount importance to the overall performance of gas turbine engines. In course of carrying out this research, turbomatch software established at Cranfield University based on gas turbine theory was applied to conduct simulation of a simple cycle (baseline two-spool helicopter turboshaft engine model with free power turbine. Similarly, some modified gas turbine cycle configurations incorporating unconventional components, such as engine cycle with low pressure compressor (LPC zero-staged, recuperated engine cycle, and intercooled/recuperated (ICR engine cycle, were also simulated. In doing so, design point (DP and off-design point (OD performances of the engine models were established. The percentage changes in performance parameters of the modified cycle engines over the simple cycle were evaluated and it was found that to a large extent, the modified engine cycles with unconventional components exhibit better performances in terms of thermal efficiency and specific fuel consumption than the traditional simple cycle engine. This research made use of public domain open source references.

  14. Making robust assessments of specialist trainees' workplace performance.

    Science.gov (United States)

    Weller, J M; Castanelli, D J; Chen, Y; Jolly, B

    2017-02-01

    Workplace-based assessments should provide a reliable measure of trainee performance, but have met with mixed success. We proposed that using an entrustability scale, where supervisors scored trainees on the level of supervision required for the case would improve the utility of compulsory mini-clinical evaluation exercise (CEX) assessments in a large anaesthesia training program. We analysed mini-CEX scores from all Australian and New Zealand College of Anaesthetists trainees submitted to an online database over a 12-month period. Supervisors' scores were adjusted for the expected supervision requirement for the case for trainees at different stages of training. We used generalisability theory to determine score reliability. 7808 assessments were available for analysis. Supervision requirements decreased significantly (P  0.7) with a feasible number of assessments. Adjusting scores against the expected supervision requirement considerably improved reliability, with G > 0.8 achieved with only nine assessments. Three per cent of trainees generated average mini-CEX scores below the expected standard. Using an entrustment scoring system, where supervisors score trainees on the level of supervision required, mini-CEX scores demonstrated moderate reliability within a feasible number of assessments, and evidence of validity. When scores were adjusted against an expected standard, underperforming trainees could be identified, and reliability much improved. Taken together with other evidence on trainee ability, the mini-CEX is of sufficient reliability for inclusion in high stakes decisions on trainee progression towards independent specialist practice. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Performance assessment of the proposed Monitored Retrievable Storage Facility

    International Nuclear Information System (INIS)

    Chockie, A.D.; Hostick, C.J.; Winter, C.

    1986-02-01

    Pacific Northwest laboratory (PNL) has completed a performance evaluation of the proposed monitored retrievable storage (MRS) facility. This study was undertaken as part of the Department of Energy MRS Program at PNL. The objective of the performance evaluation was to determine whether the conceptual MRS facility would be able to process spent fuel at the specified design rate of 3600 metric tons of uranium (MTU) per year. The performance of the proposed facility was assessed using the computer model COMPACT (Computer Optimization of Processing and Cask Transport) to simulate facility operations. The COMPACT model consisted of three application models each of which addressed a different aspect of the facility's operation: MRS/waste transportation interface; cask handling capability; and disassembly/consolidation (hot cell) operations. Our conclusions, based on the assessment of design criteria for the proposed facility, are as follows: Facilities and equipment throughout the facility have capability beyond the 3600 MTU/y design requirement. This added capability provides a reserve to compensate for unexpected perturbations in shipping or handling of the spent fuel. Calculations indicate that the facility's maximum maintainable processing capability is approximately 4800 MTU/y

  16. Total System Performance Assessment: Enhanced Design Alternative V

    International Nuclear Information System (INIS)

    N. Erb; S. Miller; V. Vallikat

    1999-01-01

    This calculation documents the total system performance assessment modeling of Enhanced Design Analysis (EDA) V. EDA V is based on the TSPA-VA base design which has been modified with higher thermal loading, a quartz sand invert, and line loading with 21 PWR waste packages that have 2-cm thick titanium grade 7 corrosion resistance material (CRM) drip shields placed over dual-layer waste packages composed of 'inside out' VA reference material (CRWMS M and O 1999a). This document details the changes and assumptions made to the VA reference Performance Assessment Model (CRWMS M and O 1998a) to incorporate the design changes detailed for EDA V. The performance measure for this evaluation is expected value dose-rate history. Time histories of dose rate are presented for EDA V and a Defense in Depth (DID) analysis base on EDA V. Additional details concerning the Enhanced Design Alternative II are provided in the 'LADS 3-12 Requests' interoffice correspondence (CRWMS M and O 1999a)

  17. Performance objectives for the Hanford immobilized low-activity waste (ILAW) performance assessment

    International Nuclear Information System (INIS)

    MANN, F.M.

    1999-01-01

    Before low-level waste may be disposed of, a performance assessment must be written and then approved by the DOE (DOE 1988a, DOE 1999a). The performance assessment is to determine whether ''reasonable assurance'' exists that the performance objectives of the disposal facility will be met. The DOE requirements for waste disposal (DOE 1988a, DOE 1999a) require (see Appendix B): The protection of public health and safety; and The protection of the environment. Although quantitative limits are sometimes stated (for example, the all-pathways exposure limit is 25 mredyear), usually the requirements are stated in a general nature. Quantitative limits were established by: investigating all potentially applicable regulations as well as interpretations of the review panels which DOE has established to review performance assessments; interacting with program management to establish the additional requirements of the program; and interacting with the public (i.e., the Hanford Advisory Board members; as well as affected Tribal Governments) to understand the values of residents in the Pacific Northwest. Because of space considerations, not all radionuclides and dangerous chemicals are listed in this document. The radionuclides listed here are those which were explicitly treated in the ILAW PA (Mann 1998). The dangerous chemicals listed here are those most often detected in Hanford tank waste as documented in the Regulatory Data Quality Objectives Supporting Tank Waste Remediation System Privatization Project (Wiemers 1998)

  18. Low-level radioactive waste performance assessments: Source term modeling

    International Nuclear Information System (INIS)

    Icenhour, A.S.; Godbee, H.W.; Miller, L.F.

    1995-01-01

    Low-level radioactive wastes (LLW) generated by government and commercial operations need to be isolated from the environment for at least 300 to 500 yr. Most existing sites for the storage or disposal of LLW employ the shallow-land burial approach. However, the U.S. Department of Energy currently emphasizes the use of engineered systems (e.g., packaging, concrete and metal barriers, and water collection systems). Future commercial LLW disposal sites may include such systems to mitigate radionuclide transport through the biosphere. Performance assessments must be conducted for LUW disposal facilities. These studies include comprehensive evaluations of radionuclide migration from the waste package, through the vadose zone, and within the water table. Atmospheric transport mechanisms are also studied. Figure I illustrates the performance assessment process. Estimates of the release of radionuclides from the waste packages (i.e., source terms) are used for subsequent hydrogeologic calculations required by a performance assessment. Computer models are typically used to describe the complex interactions of water with LLW and to determine the transport of radionuclides. Several commonly used computer programs for evaluating source terms include GWSCREEN, BLT (Breach-Leach-Transport), DUST (Disposal Unit Source Term), BARRIER (Ref. 5), as well as SOURCE1 and SOURCE2 (which are used in this study). The SOURCE1 and SOURCE2 codes were prepared by Rogers and Associates Engineering Corporation for the Oak Ridge National Laboratory (ORNL). SOURCE1 is designed for tumulus-type facilities, and SOURCE2 is tailored for silo, well-in-silo, and trench-type disposal facilities. This paper focuses on the source term for ORNL disposal facilities, and it describes improved computational methods for determining radionuclide transport from waste packages

  19. Assigning probability distributions to input parameters of performance assessment models

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Srikanta [INTERA Inc., Austin, TX (United States)

    2002-02-01

    This study presents an overview of various approaches for assigning probability distributions to input parameters and/or future states of performance assessment models. Specifically,three broad approaches are discussed for developing input distributions: (a) fitting continuous distributions to data, (b) subjective assessment of probabilities, and (c) Bayesian updating of prior knowledge based on new information. The report begins with a summary of the nature of data and distributions, followed by a discussion of several common theoretical parametric models for characterizing distributions. Next, various techniques are presented for fitting continuous distributions to data. These include probability plotting, method of moments, maximum likelihood estimation and nonlinear least squares analysis. The techniques are demonstrated using data from a recent performance assessment study for the Yucca Mountain project. Goodness of fit techniques are also discussed, followed by an overview of how distribution fitting is accomplished in commercial software packages. The issue of subjective assessment of probabilities is dealt with in terms of the maximum entropy distribution selection approach, as well as some common rules for codifying informal expert judgment. Formal expert elicitation protocols are discussed next, and are based primarily on the guidance provided by the US NRC. The Bayesian framework for updating prior distributions (beliefs) when new information becomes available is discussed. A simple numerical approach is presented for facilitating practical applications of the Bayes theorem. Finally, a systematic framework for assigning distributions is presented: (a) for the situation where enough data are available to define an empirical CDF or fit a parametric model to the data, and (b) to deal with the situation where only a limited amount of information is available.

  20. Assigning probability distributions to input parameters of performance assessment models

    International Nuclear Information System (INIS)

    Mishra, Srikanta

    2002-02-01

    This study presents an overview of various approaches for assigning probability distributions to input parameters and/or future states of performance assessment models. Specifically,three broad approaches are discussed for developing input distributions: (a) fitting continuous distributions to data, (b) subjective assessment of probabilities, and (c) Bayesian updating of prior knowledge based on new information. The report begins with a summary of the nature of data and distributions, followed by a discussion of several common theoretical parametric models for characterizing distributions. Next, various techniques are presented for fitting continuous distributions to data. These include probability plotting, method of moments, maximum likelihood estimation and nonlinear least squares analysis. The techniques are demonstrated using data from a recent performance assessment study for the Yucca Mountain project. Goodness of fit techniques are also discussed, followed by an overview of how distribution fitting is accomplished in commercial software packages. The issue of subjective assessment of probabilities is dealt with in terms of the maximum entropy distribution selection approach, as well as some common rules for codifying informal expert judgment. Formal expert elicitation protocols are discussed next, and are based primarily on the guidance provided by the US NRC. The Bayesian framework for updating prior distributions (beliefs) when new information becomes available is discussed. A simple numerical approach is presented for facilitating practical applications of the Bayes theorem. Finally, a systematic framework for assigning distributions is presented: (a) for the situation where enough data are available to define an empirical CDF or fit a parametric model to the data, and (b) to deal with the situation where only a limited amount of information is available

  1. Total System Performance Assessment for the Site Recommendation

    Energy Technology Data Exchange (ETDEWEB)

    None

    2000-10-02

    As mandated in the Nuclear Waste Policy Act of 1982, the U.S. Department of Energy (DOE) has been investigating a candidate site at Yucca Mountain, Nevada, to determine whether it is suitable for development of the nation's first repository for permanent geologic disposal of spent nuclear fuel (SNF) and high-level radioactive waste (HLW). The Nuclear Waste Policy Amendments Act of 1987 directed that only Yucca Mountain be characterized to evaluate the site's suitability. Three main components of the DOE site characterization program are testing, design, and performance assessment. These program components consist of: Investigation of natural features and processes by analyzing data collected from field tests conducted above and below ground and from laboratory tests of rock, gas, and water samples Design of a repository and waste packages tailored to the site features, supported by laboratory testing of candidate materials for waste packages and design related testing in the underground tunnels where waste would be emplaced Quantitative estimates of the performance of the total repository system, over a range of possible conditions and for different repository configurations, by means of computer modeling techniques that are based on site and materials testing data and accepted principles of physics and chemistry. To date, DOE has completed and documented four major iterations of total system performance assessment (TSPA) for the Yucca Mountain site: TSPA-91 (Barnard et al. 1992), TSPA-93 (Wilson et al. 1994; CRWMS M and O 1994), TSPA-95 (CRWMS M and O 1995), and the Total System Performance Assessment-Viability Assessment (TSPA-VA) (DOE 1998a, Volume 3). Each successive TSPA iteration has advanced the technical understanding of the performance attributes of the natural features and processes and enhanced engineering designs. The next major iteration of TSPA is to be conducted in support of the next major programmatic milestone for the DOE, namely the

  2. Historical relationship between performance assessment for radioactive waste disposal and other types of risk assessment

    International Nuclear Information System (INIS)

    Rechard, R.P.

    1999-01-01

    This article describes the evolution of the process for assessing the hazards of a geologic disposal system for radioactive waste and, similarly, nuclear power reactors, and the relationship of this process with other assessments of risk, particularly assessments of hazards from manufactured carcinogenic chemicals during use and disposal. This perspective reviews the common history of scientific concepts for risk assessment developed until the 1950s. Computational tools and techniques developed in the late 1950s and early 1960s to analyze the reliability of nuclear weapon delivery systems were adopted in the early 1970s for probabilistic risk assessment of nuclear power reactors, a technology for which behavior was unknown. In turn, these analyses became an important foundation for performance assessment of nuclear waste disposal in the late 1970s. The evaluation of risk to human health and the environment from chemical hazards is built on methods for assessing the dose response of radionuclides in the 1950s. Despite a shared background, however, societal events, often in the form of legislation, have affected the development path for risk assessment for human health, producing dissimilarities between these risk assessments and those for nuclear facilities. An important difference is the regulator's interest in accounting for uncertainty

  3. Discriminant analysis in Polish manufacturing sector performance assessment

    Directory of Open Access Journals (Sweden)

    Józef Dziechciarz

    2004-01-01

    Full Text Available This is a presentation of the preliminary results of a larger project on the determination of the attractiveness of manufacturing branches. Results of the performance assessment of Polish manufacturing branches in 2000 (section D „Manufacturing” – based on NACE – Nomenclatures des Activites de Communite Europeene are shown. In the research, the classical (Fisher’s linear discriminant analysis technique was used for the analysis of the profit generation ability by the firms belonging to a certain production branch. For estimation, the data describing group level was used – for cross-validation, the classes data.

  4. Designing a database for performance assessment: Lessons learned from WIPP

    International Nuclear Information System (INIS)

    Martell, M.A.; Schenker, A.

    1997-01-01

    The Waste Isolation Pilot Plant (WIPP) Compliance Certification Application (CCA) Performance Assessment (PA) used a relational database that was originally designed only to supply the input parameters required for implementation of the PA codes. Reviewers used the database as a point of entry to audit quality assurance measures for control, traceability, and retrievability of input information used for analysis, and output/work products. During these audits it became apparent that modifications to the architecture and scope of the database would benefit the EPA regulator and other stakeholders when reviewing the recertification application. This paper contains a discussion of the WPP PA CCA database and lessons learned for designing a database

  5. Performance assessment of advanced engineering workstations for fuel management applications

    International Nuclear Information System (INIS)

    Turinsky, P.J.

    1989-07-01

    The purpose of this project was to assess the performance of an advanced engineering workstation [AEW] with regard to applications to incore fuel management for LWRs. The attributes of most interest to us that define an AEW are parallel computational hardware and graphics capabilities. The AEWs employed were super microcomputers manufactured by MASSCOMP, Inc. These computers utilize a 32-bit architecture, graphics co-processor, multi-CPUs [up to six] attached to common memory and multi-vector accelerators. 7 refs., 33 figs., 4 tabs

  6. Environmental performance assessment of Napier grass for bioenergy production

    DEFF Research Database (Denmark)

    Nimmanterdwong, Prathana; Chalermsinsuwan, Benjapon; Østergård, Hanne

    2017-01-01

    equivalence. This idea provides the quantitative indicators involving the resource use and the percent renewability of the systems. For the proposed biorefinery model, Napier grass (Pennisetum purpureum) grown in Thailand was used as lignocellulosic feedstock. An emergy assessment was performed in two parts...... cultivation and biorefinery stages. For Napier grass cultivation, most of the emergy support came from local resources in term of evapotranspiration of Napier grass (33%) and the diesel consumption during the cultivation process (21%). The emergy sustainability indicator of the cultivation was 0...

  7. Sorption, Diffusion and Solubility Databases for Performance Assessment

    International Nuclear Information System (INIS)

    Garcia Gutierrez, M.

    2000-01-01

    This report presents a deterministic and probabilistic databases for application in Performance Assessment of a high-level radioactive waste disposal. This work includes a theoretical description of sorption, diffusion and solubility phenomena of radionuclides in geological media. The report presents and compares the databases of different nuclear wastes management agencies, describes the materials in the Spanish reference system, and the results of sorption diffusion and solubility in this system, with both the deterministic and probabilistic approximation. The probabilistic approximation is presented in the form of probability density functions (pdf). (Author) 52 refs

  8. Review of SFL 3-5 performance assessment

    International Nuclear Information System (INIS)

    Glynn, P.D.

    2000-01-01

    This 'performance assessment' report has 1) several logical flaws and 2) is not scientifically objective. There is a lot of good work done by individual SKB consultants. The problem is that the report does not consider all the available research that has been conducted, both by SKB consultants and by other scientists. The report only seems to select evidence/research pieces that fit preconceived notions supporting SKB's ultimate objectives. This is done rather poorly, which is why one can easily pick out inconsistencies and logical flaws

  9. Comfort Indicators for the Assessment of Indoor Environmental Building Performance

    DEFF Research Database (Denmark)

    Brohus, Henrik; Bendtsen, A.; Sørensen, M.

    2006-01-01

    Indoor environmental building performance assessment requires efficient indicators of the indoor comfort. In order to be effective and useful the comfort indicators must be able to include the temporal variation of indoor comfort as well as the degree of discomfort perceived by the occupants....... This paper discusses and presents a number of comfort indicators that includes both the temporal variation and the degree of discomfort in the calculations. A test case comprising a ventilated office building is used to show the application of the various comfort indices. It is found that the new comfort...

  10. Performance Assessment of a Post-Closure Pyrophoric Event

    International Nuclear Information System (INIS)

    Duguid, J.O.; Senger, R.K.; Leem, J.

    2002-01-01

    This paper describes analyses of a potential post-closure pyrophoric event in a waste package containing uranium metal spent fuel. The analyses include temperature at adjacent waste packages caused by the event and the dose to humans due to the event. The thermal analyses show that the event would not be expected to damage the adjacent waste packages. The dose analyses show that the doses due to the event are small. These analyses provide support to screening arguments used to demonstrate that the pyrophoric event should not be considered in the total system performance assessment model

  11. Annual Summary of the Integrated Disposal Facility Performance Assessment 2012

    Energy Technology Data Exchange (ETDEWEB)

    Khaleel, R. [INTERA, Austin, TX (United States); Nichols, W. E. [CH2M HILL Plateau Remediation Company, Richland, WA (United States)

    2012-12-27

    An annual summary of the adequacy of the Hanford Immobilized Low-Activity Waste (ILAW) Performance Assessment (PA) is required each year (DOE O 435.1 Chg 1,1 DOE M 435.1-1 Chg 1;2 and DOE/ORP-2000-013). The most recently approved PA is DOE/ORP-2000-24.4 The ILAW PA evaluated the adequacy of the ILAW disposal facility, now referred to as the Integrated Disposal Facility (IDF), for the safe disposal of vitrified Hanford Site tank waste.

  12. Predicting Performance on MOOC Assessments using Multi-Regression Models

    OpenAIRE

    Ren, Zhiyun; Rangwala, Huzefa; Johri, Aditya

    2016-01-01

    The past few years has seen the rapid growth of data min- ing approaches for the analysis of data obtained from Mas- sive Open Online Courses (MOOCs). The objectives of this study are to develop approaches to predict the scores a stu- dent may achieve on a given grade-related assessment based on information, considered as prior performance or prior ac- tivity in the course. We develop a personalized linear mul- tiple regression (PLMR) model to predict the grade for a student, prior to attempt...

  13. Employment of kernel methods on wind turbine power performance assessment

    DEFF Research Database (Denmark)

    Skrimpas, Georgios Alexandros; Sweeney, Christian Walsted; Marhadi, Kun S.

    2015-01-01

    A power performance assessment technique is developed for the detection of power production discrepancies in wind turbines. The method employs a widely used nonparametric pattern recognition technique, the kernel methods. The evaluation is based on the trending of an extracted feature from...... the kernel matrix, called similarity index, which is introduced by the authors for the first time. The operation of the turbine and consequently the computation of the similarity indexes is classified into five power bins offering better resolution and thus more consistent root cause analysis. The accurate...

  14. A Fuzzy Knowledge Representation Model for Student Performance Assessment

    DEFF Research Database (Denmark)

    Badie, Farshad

    Knowledge representation models based on Fuzzy Description Logics (DLs) can provide a foundation for reasoning in intelligent learning environments. While basic DLs are suitable for expressing crisp concepts and binary relationships, Fuzzy DLs are capable of processing degrees of truth/completene......Knowledge representation models based on Fuzzy Description Logics (DLs) can provide a foundation for reasoning in intelligent learning environments. While basic DLs are suitable for expressing crisp concepts and binary relationships, Fuzzy DLs are capable of processing degrees of truth....../completeness about vague or imprecise information. This paper tackles the issue of representing fuzzy classes using OWL2 in a dataset describing Performance Assessment Results of Students (PARS)....

  15. Control Performance Management in Industrial Automation Assessment, Diagnosis and Improvement of Control Loop Performance

    CERN Document Server

    Jelali, Mohieddine

    2013-01-01

    Control Performance Management in Industrial Automation provides a coherent and self-contained treatment of a group of methods and applications of burgeoning importance to the detection and solution of problems with control loops that are vital in maintaining product quality, operational safety, and efficiency of material and energy consumption in the process industries. The monograph deals with all aspects of control performance management (CPM), from controller assessment (minimum-variance-control-based and advanced methods), to detection and diagnosis of control loop problems (process non-linearities, oscillations, actuator faults), to the improvement of control performance (maintenance, re-design of loop components, automatic controller re-tuning). It provides a contribution towards the development and application of completely self-contained and automatic methodologies in the field. Moreover, within this work, many CPM tools have been developed that goes far beyond available CPM packages. Control Perform...

  16. Performance Assessment Method for a Forged Fingerprint Detection Algorithm

    Science.gov (United States)

    Shin, Yong Nyuo; Jun, In-Kyung; Kim, Hyun; Shin, Woochang

    The threat of invasion of privacy and of the illegal appropriation of information both increase with the expansion of the biometrics service environment to open systems. However, while certificates or smart cards can easily be cancelled and reissued if found to be missing, there is no way to recover the unique biometric information of an individual following a security breach. With the recognition that this threat factor may disrupt the large-scale civil service operations approaching implementation, such as electronic ID cards and e-Government systems, many agencies and vendors around the world continue to develop forged fingerprint detection technology, but no objective performance assessment method has, to date, been reported. Therefore, in this paper, we propose a methodology designed to evaluate the objective performance of the forged fingerprint detection technology that is currently attracting a great deal of attention.

  17. Lysimeter data as input to performance assessment source term codes

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Rogers, R.D.; Sullivan, T.

    1992-01-01

    The Field Lysimeter Investigation: Low-Level Waste Data Base Development Program is obtaining information on the performance of radioactive waste in a disposal environment. Waste forms fabricated using ion-exchange resins from EPICOR-II c prefilters employed in the cleanup of the Three Mile Island (TMI) Nuclear Power Station are being tested to develop a low-level waste data base and to obtain information on survivability of waste forms in a disposal environment. In this paper, radionuclide releases from waste forms in the first seven years of sampling are presented and discussed. Application of lysimeter data to be used in performance assessment source term models is presented. Initial results from use of data in two models are discussed

  18. Lysimeter data as input to performance assessment models

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.

    1998-01-01

    The Field Lysimeter Investigations: Low-Level Waste Data Base Development Program is obtaining information on the performance of radioactive waste forms in a disposal environment. Waste forms fabricated using ion-exchange resins from EPICOR-117 prefilters employed in the cleanup of the Three Mile Island (TMI) Nuclear Power Station are being tested to develop a low-level waste data base and to obtain information on survivability of waste forms in a disposal environment. The program includes reviewing radionuclide releases from those waste forms in the first 7 years of sampling and examining the relationship between code input parameters and lysimeter data. Also, lysimeter data are applied to performance assessment source term models, and initial results from use of data in two models are presented

  19. Experimental Methods for UAV Aerodynamic and Propulsion Performance Assessment

    Directory of Open Access Journals (Sweden)

    Stefan ANTON

    2015-06-01

    Full Text Available This paper presents an experimental method for assessing the performances and the propulsion power of a UAV in several points based on telemetry. The points in which we make the estimations are chosen based on several criteria and the fallowing parameters are measured: airspeed, time-to-climb, altitude and the horizontal distance. With the estimated propulsion power and knowing the shaft motor power, the propeller efficiency is determined at several speed values. The shaft motor power was measured in the lab using the propeller as a break. Many flights, using the same UAV configuration, were performed before extracting flight data, in order to reduce the instrumental or statistic errors. This paper highlights both the methodology of processing the data and the validation of theoretical results.

  20. Performance Assessment of a Post-Closure Pyrophoric Event

    International Nuclear Information System (INIS)

    Duguid, James; Senger, R.; Leem, J.

    2001-01-01

    The U.S. Department of Energy (DOE) spent nuclear fuel (DSNF) is categorized into eleven different spent fuel groups. Group 7, is predominantly uranium metal spent fuel from N Reactor that could oxidize rapidly in the presence of air when a waste package is breached. Such rapid oxidation constitutes a pyrophoric event. The consequences of a post closure pyrophoric event were evaluated in terms of its potential to damage adjacent waste packages and consequences of it in terms of long-term dose to humans. This work was conducted as part of the total system performance assessment (TSPA) of DOE spent fuel for the National Spent Nuclear Fuel Program. These analyses were performed in support of the site recommendation for a repository at Yucca Mountain, Nevada

  1. WIPP [Waste Isolation Pilot Plant] test phase plan: Performance assessment

    International Nuclear Information System (INIS)

    1990-04-01

    The U.S. Department of Energy (DOE) is responsible for managing the disposition of transuranic (TRU) wastes resulting from nuclear weapons production activities of the United States. These wastes are currently stored nationwide at several of the DOE's waste generating/storage sites. The goal is to eliminate interim waste storage and achieve environmentally and institutionally acceptable permanent disposal of these TRU wastes. The Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico is being considered as a disposal facility for these TRU wastes. This document describes the first of the following two major programs planned for the Test Phase of WIPP: Performance Assessment -- determination of the long-term performance of the WIPP disposal system in accordance with the requirements of the EPA Standard; and Operations Demonstration -- evaluation of the safety and effectiveness of the DOE TRU waste management system's ability to emplace design throughput quantities of TRU waste in the WIPP underground facility. 120 refs., 19 figs., 8 tabs

  2. Personality Profiles of Effective Leadership Performance in Assessment Centers.

    Science.gov (United States)

    Parr, Alissa D; Lanza, Stephanie T; Bernthal, Paul

    2016-01-01

    Most research examining the relationship between effective leadership and personality has focused on individual personality traits. However, profiles of personality traits more fully describe individuals, and these profiles may be important as they relate to leadership. This study used latent class analysis to examine how personality traits combine and interact to form subpopulations of leaders, and how these subpopulations relate to performance criteria. Using a sample of 2,461 executive-level leaders, six personality profiles were identified: Unpredictable Leaders with Low Diligence (7.3%); Conscientious, Backend Leaders (3.6%); Unpredictable Leaders (8.6%); Creative Communicators (20.8%); Power Players (32.4%); and Protocol Followers (27.1%). One profile performed well on all criteria in an assessment center; remaining profiles exhibited strengths and weaknesses across criteria. Implications and future directions for research are highlighted.

  3. Video Quality Assessment and Machine Learning: Performance and Interpretability

    DEFF Research Database (Denmark)

    Søgaard, Jacob; Forchhammer, Søren; Korhonen, Jari

    2015-01-01

    In this work we compare a simple and a complex Machine Learning (ML) method used for the purpose of Video Quality Assessment (VQA). The simple ML method chosen is the Elastic Net (EN), which is a regularized linear regression model and easier to interpret. The more complex method chosen is Support...... Vector Regression (SVR), which has gained popularity in VQA research. Additionally, we present an ML-based feature selection method. Also, it is investigated how well the methods perform when tested on videos from other datasets. Our results show that content-independent cross-validation performance...... on a single dataset can be misleading and that in the case of very limited training and test data, especially in regards to different content as is the case for many video datasets, a simple ML approach is the better choice....

  4. Waste package performance assessment for the Yucca Mountain project

    International Nuclear Information System (INIS)

    O'Connell, W.J.; Lappa, D.A.; Thatcher, R.M.

    1989-01-01

    The authors completed a first cycle of model development from a specification to a computer program, PANDORA-1, for long-term performance assessment of waste packages. The model for one waste package at a time incorporates processes specific to the unsaturated environment at the proposed Yucca Mountain, NV, site. PANDORA-1 models the most likely processes and several modes of waste alteration and release. The development identified information needs for future models; many processes, local details, and combinations will have to be examined. Integration of ensemble performance and quantification of uncertainties are modeling steps at higher aggregation. Methodologies for these steps include sampling, which is well studied; we have focused on several open questions. The authors can now calculate the amount of variance reduction available from Latin hypercube sampling; it is a limited reduction. A new method, uncertainty analysis test-bed program compares the new with old sampling methods

  5. PORFLOW Modeling Supporting The H-Tank Farm Performance Assessment

    International Nuclear Information System (INIS)

    Jordan, J. M.; Flach, G. P.; Westbrook, M. L.

    2012-01-01

    Numerical simulations of groundwater flow and contaminant transport in the vadose and saturated zones have been conducted using the PORFLOW code in support of an overall Performance Assessment (PA) of the H-Tank Farm. This report provides technical detail on selected aspects of PORFLOW model development and describes the structure of the associated electronic files. The PORFLOW models for the H-Tank Farm PA, Rev. 1 were updated with grout, solubility, and inventory changes. The aquifer model was refined. In addition, a set of flow sensitivity runs were performed to allow flow to be varied in the related probabilistic GoldSim models. The final PORFLOW concentration values are used as input into a GoldSim dose calculator

  6. PORFLOW Modeling Supporting The H-Tank Farm Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, J. M.; Flach, G. P.; Westbrook, M. L.

    2012-08-31

    Numerical simulations of groundwater flow and contaminant transport in the vadose and saturated zones have been conducted using the PORFLOW code in support of an overall Performance Assessment (PA) of the H-Tank Farm. This report provides technical detail on selected aspects of PORFLOW model development and describes the structure of the associated electronic files. The PORFLOW models for the H-Tank Farm PA, Rev. 1 were updated with grout, solubility, and inventory changes. The aquifer model was refined. In addition, a set of flow sensitivity runs were performed to allow flow to be varied in the related probabilistic GoldSim models. The final PORFLOW concentration values are used as input into a GoldSim dose calculator.

  7. Performance Shaping Factors Assessments and Application to PHWR Outages

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Woo

    2007-02-15

    Human reliability analysis is definitely related to the quality of PSA because human errors have been identified as major contributors to PSA. According to NRC's 'Office of analysis and evaluation of operational data (AEOD)',82% of the reactor trips and accident during outage is caused by the events related to human errors. There is, however, no one HRA method universally accepted. Furthermore, HRA during PHWR outages has not been performed around the world yet. HRA during PHWR outages is especially important since manual management of operator is more required during PHWR. In this study, accident scenarios which HYU developed are used to perform a quantification of human error probability. In this study, overall procedures of standard HRA methodology are introduced and follows the quantification of 10 possible selected human actions during PHWR outages based on standard HRA methodology. To see the verification, quantified values were compared with the values from 'Generic CANDU Probabilistic Safety Assessment' and the values estimated by ASEP.Core Damage Frequency was estimated 3.35 x 10{sup -4} more higher than CDF estimated by AECL data. It was considered that the differences between the HEPs for OPAFW and OPECC3 make CDF higher. Therefore, complementary study of reestimating HEP for OPAFW and OPECC3 in detail is required for increasing the qualities of HRA and PSA. Moreover, one of the difficulties in performing human reliability analysis is to evaluate performance shaping factors which represent the characteristics and circumstances. For assessing a specific human action more exactly, it is necessary to consider all of the PSFs at the same time which makes an effect on the human action. Also, it requires the effect comparison among PSFs to minimize the uncertainties which are usually caused by the subjective judgements of HRA analysts. To see the sensitivity, performance shaping factors of each decision rule are changed which resulted

  8. Performance Shaping Factors Assessments and Application to PHWR Outages

    International Nuclear Information System (INIS)

    Lee, Seung Woo

    2007-02-01

    Human reliability analysis is definitely related to the quality of PSA because human errors have been identified as major contributors to PSA. According to NRC's 'Office of analysis and evaluation of operational data (AEOD)',82% of the reactor trips and accident during outage is caused by the events related to human errors. There is, however, no one HRA method universally accepted. Furthermore, HRA during PHWR outages has not been performed around the world yet. HRA during PHWR outages is especially important since manual management of operator is more required during PHWR. In this study, accident scenarios which HYU developed are used to perform a quantification of human error probability. In this study, overall procedures of standard HRA methodology are introduced and follows the quantification of 10 possible selected human actions during PHWR outages based on standard HRA methodology. To see the verification, quantified values were compared with the values from 'Generic CANDU Probabilistic Safety Assessment' and the values estimated by ASEP.Core Damage Frequency was estimated 3.35 x 10 -4 more higher than CDF estimated by AECL data. It was considered that the differences between the HEPs for OPAFW and OPECC3 make CDF higher. Therefore, complementary study of reestimating HEP for OPAFW and OPECC3 in detail is required for increasing the qualities of HRA and PSA. Moreover, one of the difficulties in performing human reliability analysis is to evaluate performance shaping factors which represent the characteristics and circumstances. For assessing a specific human action more exactly, it is necessary to consider all of the PSFs at the same time which makes an effect on the human action. Also, it requires the effect comparison among PSFs to minimize the uncertainties which are usually caused by the subjective judgements of HRA analysts. To see the sensitivity, performance shaping factors of each decision rule are changed which resulted in changes of core damage

  9. [Software for performing a global phenotypic and genotypic nutritional assessment].

    Science.gov (United States)

    García de Diego, L; Cuervo, M; Martínez, J A

    2013-01-01

    The nutritional assessment of a patient needs the simultaneous managing a extensive information and a great number of databases, as both aspects of the process of nutrition and the clinical situation of the patient are analyzed. The introduction of computers in the nutritional area constitutes an extraordinary advance in the administration of nutrition information, providing a complete assessment of nutritional aspects in a quick and easy way. To develop a computer program that can be used as a tool for assessing the nutritional status of the patient, the education of clinical staff, for epidemiological studies and for educational purposes. Based on a computer program which assists the health specialist to perform a full nutritional evaluation of the patient, through the registration and assessment of the phenotypic and genotypic features. The application provides nutritional prognosis based on anthropometric and biochemical parameters, images of states of malnutrition, questionnaires to characterize diseases, diagnostic criteria, identification of alleles associated with the development of specific metabolic illnesses and questionnaires of quality of life, for a custom actuation. The program includes, as part of the nutritional assessment of the patient, food intake analysis, design of diets and promotion of physical activity, introducing food frequency questionnaires, dietary recalls, healthy eating indexes, model diets, fitness tests, and recommendations, recalls and questionnaires of physical activity. A computer program performed under Java Swing, using SQLite database and some external libraries such as JfreeChart for plotting graphs. This brand new designed software is composed of five blocks categorized into ten modules named: Patients, Anthropometry, Clinical History, Biochemistry, Dietary History, Diagnostic (with genetic make up), Quality of life, Physical activity, Energy expenditure and Diets. Each module has a specific function which evaluates a

  10. Anaortic off-pump versus clampless off-pump using the PAS-Port device versus conventional coronary artery bypass grafting: mid-term results from a matched propensity score analysis of 5422 unselected patients.

    Science.gov (United States)

    Furukawa, Nobuyuki; Kuss, Oliver; Preindl, Konstantin; Renner, André; Aboud, Anas; Hakim-Meibodi, Kavous; Benzinger, Michael; Pühler, Thomas; Ensminger, Stephan; Fujita, Buntaro; Becker, Tobias; Gummert, Jan F; Börgermann, Jochen

    2017-10-01

    Meta-analyses from observational and randomized studies have demonstrated benefits of off-pump surgery for hard and surrogate endpoints. In some of them, increased re-revascularization was noted in the off-pump groups, which could impact their long-term survival. Therefore, we analyzed the course of all patients undergoing isolated coronary surgery regarding the major cardiac and cerebrovascular event (MACCE) criteria. A prospective register was taken from a high-volume off-pump center recording all anaortic off-pump (ANA), clampless off-pump (PAS-Port) and conventional (CONV) coronary artery bypass operations between July 2009 and June 2015. Propensity Score Matching was performed based on 28 preoperative risk variables. We identified 935 triplets (N = 2805). Compared with CONV, in-hospital mortality of both the ANA group (OR for ANA [95% CI] 0.25 [0.06; 0.83], P = 0.021), and the PAS-Port group was lower (OR for PAS-Port [95% CI] 0.50 [0.17; 1.32], P = 0.17). In the mid-term follow-up there were no significant differences between the groups regarding mortality (HR for ANA [95%-CI] 0.83 [0.55-1.26], P = 0.38; HR for PAS-Port [95%-CI] 1.06 [0.70-1.59], P = 0.79), incidence of stroke (HR for ANA 0.81 [0.43-1.53], P = 0.52; HR for PAS-Port 0.78 [0.41-1.50], P = 0.46), myocardial infarction (HR for ANA 0.53 [0.22-1.31], P = 0.17; HR for PAS-Port 0.78 [0.37-1.66], P = 0.52) or re-revascularization rate (HR for ANA 0.99 [0.67-1.44], P = 0.94; HR for PAS-Port 0.95 [0.65-1.38], P = 0.77). Both off-pump clampless techniques were associated with lower in-hospital mortality compared with conventional CABG. The mid-term course showed no difference with regard to the MACCE criteria between anaortic off-pump, clampless off-pump using PAS-Port and conventional CABG. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  11. Real-Time Assessment and Diagnosis of Process Operating Performance

    Directory of Open Access Journals (Sweden)

    Shabnam Sedghi

    2017-04-01

    Full Text Available Over time, the performance of processes may deviate from the initial design due to process variations and uncertainties, making it necessary to develop systematic methods for online optimality assessment based on routine operating process data. Some processes have multiple operating modes caused by the set point change of the critical process variables to achieve different product specifications. On the other hand, the operating region in each operating mode can alter, due to uncertainties. In this paper, we will establish an optimality assessment framework for processes that typically have multi-mode, multi-region operations, as well as transitions between different modes. The kernel density approach for mode detection is adopted and improved for operating mode detection. For online mode detection, the model-based clustering discriminant analysis (MclustDA approach is incorporated with some a priori knowledge of the system. In addition, multi-modal behavior of steady-state modes is tackled utilizing the mixture probabilistic principal component regression (MPPCR method, and dynamic principal component regression (DPCR is used to investigate transitions between different modes. Moreover, a probabilistic causality detection method based on the sequential forward floating search (SFFS method is introduced for diagnosing poor or non-optimum behavior. Finally, the proposed method is tested on the Tennessee Eastman (TE benchmark simulation process in order to evaluate its performance.

  12. THE PENA BLANCA NATURAL ANALOGUE PERFORMANCE ASSESSMENT MODEL

    Energy Technology Data Exchange (ETDEWEB)

    G. Saulnier and W. Statham

    2006-04-16

    The Nopal I uranium mine in the Sierra Pena Blanca, Chihuahua, Mexico serves as a natural analogue to the Yucca Mountain repository. The Pena Blanca Natural Analogue Performance Assessment Model simulates the mobilization and transport of radionuclides that are released from the mine and transported to the saturated zone. The Pena Blanca Natural Analogue Performance Assessment Model uses probabilistic simulations of hydrogeologic processes that are analogous to the processes that occur at the Yucca Mountain site. The Nopal I uranium deposit lies in fractured, welded, and altered rhyolitic ash-flow tuffs that overlie carbonate rocks, a setting analogous to the geologic formations at the Yucca Mountain site. The Nopal I mine site has the following analogous characteristics as compared to the Yucca Mountain repository site: (1) Analogous source--UO{sub 2} uranium ore deposit = spent nuclear fuel in the repository; (2) Analogous geology--(i.e. fractured, welded, and altered rhyolitic ash-flow tuffs); (3) Analogous climate--Semiarid to arid; (4) Analogous setting--Volcanic tuffs overlie carbonate rocks; and (5) Analogous geochemistry--Oxidizing conditions Analogous hydrogeology: The ore deposit lies in the unsaturated zone above the water table.

  13. THE PENA BLANCA NATURAL ANALOGUE PERFORMANCE ASSESSMENT MODEL

    International Nuclear Information System (INIS)

    G. Saulnier; W. Statham

    2006-01-01

    The Nopal I uranium mine in the Sierra Pena Blanca, Chihuahua, Mexico serves as a natural analogue to the Yucca Mountain repository. The Pena Blanca Natural Analogue Performance Assessment Model simulates the mobilization and transport of radionuclides that are released from the mine and transported to the saturated zone. The Pena Blanca Natural Analogue Performance Assessment Model uses probabilistic simulations of hydrogeologic processes that are analogous to the processes that occur at the Yucca Mountain site. The Nopal I uranium deposit lies in fractured, welded, and altered rhyolitic ash-flow tuffs that overlie carbonate rocks, a setting analogous to the geologic formations at the Yucca Mountain site. The Nopal I mine site has the following analogous characteristics as compared to the Yucca Mountain repository site: (1) Analogous source--UO 2 uranium ore deposit = spent nuclear fuel in the repository; (2) Analogous geology--(i.e. fractured, welded, and altered rhyolitic ash-flow tuffs); (3) Analogous climate--Semiarid to arid; (4) Analogous setting--Volcanic tuffs overlie carbonate rocks; and (5) Analogous geochemistry--Oxidizing conditions Analogous hydrogeology: The ore deposit lies in the unsaturated zone above the water table

  14. Spatial variability and parametric uncertainty in performance assessment models

    International Nuclear Information System (INIS)

    Pensado, Osvaldo; Mancillas, James; Painter, Scott; Tomishima, Yasuo

    2011-01-01

    The problem of defining an appropriate treatment of distribution functions (which could represent spatial variability or parametric uncertainty) is examined based on a generic performance assessment model for a high-level waste repository. The generic model incorporated source term models available in GoldSim ® , the TDRW code for contaminant transport in sparse fracture networks with a complex fracture-matrix interaction process, and a biosphere dose model known as BDOSE TM . Using the GoldSim framework, several Monte Carlo sampling approaches and transport conceptualizations were evaluated to explore the effect of various treatments of spatial variability and parametric uncertainty on dose estimates. Results from a model employing a representative source and ensemble-averaged pathway properties were compared to results from a model allowing for stochastic variation of transport properties along streamline segments (i.e., explicit representation of spatial variability within a Monte Carlo realization). We concluded that the sampling approach and the definition of an ensemble representative do influence consequence estimates. In the examples analyzed in this paper, approaches considering limited variability of a transport resistance parameter along a streamline increased the frequency of fast pathways resulting in relatively high dose estimates, while those allowing for broad variability along streamlines increased the frequency of 'bottlenecks' reducing dose estimates. On this basis, simplified approaches with limited consideration of variability may suffice for intended uses of the performance assessment model, such as evaluation of site safety. (author)

  15. Variables and Challenges in Assessing EU Experts’ Performance

    Directory of Open Access Journals (Sweden)

    Cathrine Holst

    2015-03-01

    Full Text Available Expert advice in political processes is supposed to improve decisions. If expertise fails in this function, a legitimacy problem occurs: granting political power to experts may be defensible, but only on the grounds that it contributes to enlightening political processes and facilitate problem-solving. The paper provides a theoretical exploration of four variables that are key when assessing the epistemic quality of expert deliberations: the degree to which these deliberations are 1 informed by technical expertise, 2 regulated by epistemically optimal respect and inclusion norms, 3 focused on politically relevant and applicable knowledge, and 4 approaching questions involving moral judgment and standard setting competently. Previous research on the European Commission’s use of expert advice has more or less overlooked the question of experts’ epistemic performance, and this paper discusses the possible reasons for this in light of well-known methodological challenges in studies of elite behaviour; access and bias problems. A discussion of the merits and limitations of different available data on the Commission experts shows that the biggest obstacle in the study of experts’ epistemic performance is rather the problem of epistemic asymmetry, i.e. of how researchers as non-experts can assess the epistemic quality of experts’ contributions and behaviour. The paper offers, finally, a set of strategies to get research going despite this problem.

  16. Total System Performance Assessment - License Application Methods and Approach

    Energy Technology Data Exchange (ETDEWEB)

    J. McNeish

    2003-12-08

    ''Total System Performance Assessment-License Application (TSPA-LA) Methods and Approach'' provides the top-level method and approach for conducting the TSPA-LA model development and analyses. The method and approach is responsive to the criteria set forth in Total System Performance Assessment Integration (TSPAI) Key Technical Issues (KTIs) identified in agreements with the U.S. Nuclear Regulatory Commission, the ''Yucca Mountain Review Plan'' (YMRP), ''Final Report'' (NRC 2003 [163274]), and the NRC final rule 10 CFR Part 63 (NRC 2002 [156605]). This introductory section provides an overview of the TSPA-LA, the projected TSPA-LA documentation structure, and the goals of the document. It also provides a brief discussion of the regulatory framework, the approach to risk management of the development and analysis of the model, and the overall organization of the document. The section closes with some important conventions that are used in this document.

  17. The role of natural analogues in performance assessment

    International Nuclear Information System (INIS)

    Ewing, R.C.

    1992-01-01

    One of the unique and scientifically most challenging aspects of nuclear waste isolation is the extrapolation of short-term laboratory data (hours to years) to the long time periods (10 3 - 10 5 years) required by regulatory agencies for performance assessment. The direct verification of these extrapolations is not possible, but methods must be developed to demonstrate compliance with government regulations and to satisfy the lay public that there is a demonstrable and reasonable basis for accepting the long-term extrapolations. Natural systems provide perhaps the only means of partial verification, as well as data that may be used directly in the models that are used in the extrapolation. Natural systems provide data on very large spatial (m to km) and temporal (10 3 - 10 8 years) scales, and in highly complex terranes in which unknown synergisms may effect radionuclide migration. This paper reviews the application (and most importantly, the limitations) of data from natural analogue systems to the verification of performance assessments

  18. Performance assessment of DOE spent nuclear fuel and surplus plutonium

    International Nuclear Information System (INIS)

    Duguid, J.O.; Vallikat, V.; McNeish, J.

    1998-01-01

    Yucca Mountain, in southern Nevada, is under consideration by the US Department of Energy (DOE) as a potential site for the disposal of the nation's radioactive wastes in a geologic repository. The wastes consist of commercial spent fuel, DOE spent nuclear fuel (SNF), high level waste (HLW), and surplus plutonium. The DOE was mandated by Congress in the fiscal 1997 Energy and Water Appropriations Act to complete a viability assessment (VA) of the repository in September of 1998. The assessment consists of a preliminary design concept for the critical elements of the repository, a total system performance assessment (TSPA), a plan and cost estimate for completion of the license application, and an estimate of the cost to construct and operate the repository. This paper presents the results of the sensitivity analyses that were conducted to examine the behavior of DOE SNF and plutonium waste forms in the environment of the base case repository that was modeled for the TSPA-VA. Fifteen categories of DOE SNF and two Plutonium waste forms were examined and their contribution to radiation dose to humans was evaluated

  19. Cracking pattern and seismic performance assessment of the Orvieto cathedral

    International Nuclear Information System (INIS)

    De Canio, G.

    2015-01-01

    In this paper are described the in situ cracking pattern measurement and ambient vibration monitoring for the seismic performance evaluation of the Orvieto Cathedral Italy, according the deplacement based safety assessment. This requires, as a first step, the direct measurement of the cracking pattern and dynamic response of the structural macro elements of the cathedral due to weak vibrations induced by traffic and seismic micro tremors. Seismic assessment for this type of structure require also the proper limit states definitions. In fact, in the case historic monuments like churches, due to the presence of specific typology of macro elements: rigid blocks, complex vault systems, slenderness of the walls, presence of wide halls, domes and drums with particular geometry, is necessary to define the proper assessment procedures which are slightly different with respect those required for conventional civil industrial buildings. Regarding the Ambient vibration monitoring, a new approach to estimate the participating masses associated to the macro element kinematics is defined: it is based on the frequency contribution to the Root Main Square Acceleration, obtained by numerical integration of the Power Spectral Density (PSD) function. This information, when associated to the analysis of the Real and Imaginary part of the Cross Spectral Density (CSD) function between the acceleration time histories at different points, allow to identify the principal (at least first and second) mode shapes of the structure.

  20. ITER-EDA physics design requirements and plasma performance assessments

    International Nuclear Information System (INIS)

    Uckan, N.A.; Galambos, J.; Wesley, J.; Boucher, D.; Perkins, F.; Post, D.; Putvinski, S.

    1996-01-01

    Physics design guidelines, plasma performance estimates, and sensitivity of performance to changes in physics assumptions are presented for the ITER-EDA Interim Design. The overall ITER device parameters have been derived from the performance goals using physics guidelines based on the physics R ampersand D results. The ITER-EDA design has a single-null divertor configuration (divertor at the bottom) with a nominal plasma current of 21 MA, magnetic field of 5.68 T, major and minor radius of 8.14 m and 2.8 m, and a plasma elongation (at the 95% flux surface) of ∼1.6 that produces a nominal fusion power of ∼1.5 GW for an ignited burn pulse length of ≥1000 s. The assessments have shown that ignition at 1.5 GW of fusion power can be sustained in ITER for 1000 s given present extrapolations of H-mode confinement (τ E = 0.85 x τ ITER93H ), helium exhaust (τ* He /τ E = 10), representative plasma impurities (n Be /n e = 2%), and beta limit [β N = β(%)/(I/aB) ≤ 2.5]. The provision of 100 MW of auxiliary power, necessary to access to H-mode during the approach to ignition, provides for the possibility of driven burn operations at Q = 15. This enables ITER to fulfill its mission of fusion power (∼ 1--1.5 GW) and fluence (∼1 MWa/m 2 ) goals if confinement, impurity levels, or operational (density, beta) limits prove to be less favorable than present projections. The power threshold for H-L transition, confinement uncertainties, and operational limits (Greenwald density limit and beta limit) are potential performance limiting issues. Improvement of the helium exhaust (τ* He /τ E ≤ 5) and potential operation in reverse-shear mode significantly improve ITER performance

  1. Le big bang n'est pas une théorie comme les autres

    CERN Document Server

    Bonnet-Bidaud, Jean-Marc; Leglu, Dominique; Reinisch, Gilbert

    2009-01-01

    Le big bang n'est pas une théorie comme les autres. Ce n'est d'ailleurs pas une théorie physique au sens propre du terme, mais un scénario cosmologique issu des équations de la relativité générale. Il est le modèle qui s'ajuste le mieux aux observations actuelles, mais à quel prix ? Il nous livre un Univers composé à 96 % de matière et d'énergie noires inconnues. C'est donc un euphémisme que de dire que le big bang semble poser autant - sinon plus - de questions qu'il n'en résout. En ce sens, le big bang apparaît davantage comme une paramétrisation de notre ignorance plutôt que comme une modélisation d'un phénomène. Pourtant, le succès du big bang et l'adhésion qu'il suscite, tant dans la sphère scientifique que dans la sphère médiatique, ne se démentent pas. Surmédiatisé, son statut dépasse celui de modèle théorique, et la simple évocation de son nom suffit pour justifier des opérations de marketing scientifique ou rejeter des cosmologies alternatives. Pour éclaircir les pr...

  2. Second Annual Maintenance, Inspection, and Test Report for PAS-1 Cask Certification for Shipping Payload B

    International Nuclear Information System (INIS)

    KELLY, D.J.

    2000-01-01

    The Nuclear Packaging, Inc. (NuPac), PAS-1 cask is required to undergo annual maintenance and inspections to retain certification in accordance with U.S. Department of Energy (DOE) Certificate of Compliance USA/9184B(U) (Appendix A). The packaging configuration being tested and maintained is the NuPac PAS-1 cask for Payload B. The intent of the maintenance and inspections is to ensure the packaging remains in unimpaired physical condition. Two casks, serial numbers 2162-026 and 2162-027, were maintained, inspected, and tested at the 306E Development, Fabrication, and Test Laboratory, located at the Hanford Site's 300 Area. Waste Management Federal Services, Inc. (WMFS), a subsidiary of GTS Duratek, was in charge of the maintenance and testing. Cogema Engineering Corporation (Cogema) directed the operations in the test facility. The maintenance, testing, and inspections were conducted successfully with both PAS-1 casks. The work conducted on the overpacks included weighing, gasket replacement, and plastic pipe plug and foam inspections. The work conducted on the secondary containment vessel (SCV) consisted of visual inspection of the vessel and threaded parts (i.e., fasteners), visual inspection of sealing surfaces, replacement of O-ring seals, and a helium leak test. The work conducted on the primary containment vessel (PCV) consisted of visual inspection of the vessel and threaded parts (i.e., fasteners), visual inspection of sealing surfaces, replacement of O-ring seals, dimensional inspection of the vessel bottom, a helium leak test, and dye penetrant inspection of the welds. The vermiculite material used in the cask rack assembly was replaced

  3. Sensitivity assessment of fuel performance codes for LOCA accident scenario

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Alfredo; Gomes, Daniel; Silva, Antonio Teixeira e; Muniz, Rafael O.R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Giovedi, Claudia; Martins, Marcelo, E-mail: ayabe@ipen.br, E-mail: claudia.giovedi@labrisco.usp.br [Universidade de Sao Paulo (LABRISCO/USP), Sao Paulo, SP (Brazil). Lab. de Análise, Avaliação e Gerenciamento de Risco

    2017-07-01

    FRAPCON code predicts fuel rod performance in LWR (Light Water Reactor) by modeling fuel responses under normal operating conditions and anticipated operational occurrences; FRAPTRAN code is applied for fuel transient under fast transient and accident conditions. The codes are well known and applied for different purposes and one of the use is to address sensitivity analysis considering fuel design parameters associated to fabrication, moreover can address the effect of physical models bias. The objective of this work was to perform an assessment of fuel manufacturing parameters tolerances and fuel models bias using FRAPCON and FRAPTRAN codes for Loss of Coolant Accident (LOCA) scenario. The preliminary analysis considered direct approach taken into account most relevant manufacturing tolerances (lower and upper bounds) related to design parameters and physical models bias without considering their statistical distribution. The simulations were carried out using the data available in the open literature related to the series of LOCA experiment performed at the Halden reactor (specifically IFA-650.5). The manufacturing tolerances associated to design parameters considered in this paper were: enrichment, cladding thickness, pellet diameter, pellet density, and filling gas pressure. The physical models considered were: fuel thermal expansion, fission gas release, fuel swelling, irradiation creep, cladding thermal expansion, cladding corrosion, and cladding hydrogen pickup. The results obtained from sensitivity analysis addressed the impact of manufacturing tolerances and physical models in the fuel cladding burst time observed for the IFA-650.5 experiment. (author)

  4. Performance Assessment for e-Government Services: An Experience Report

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yan; Zhu, Liming; Gorton, Ian

    2007-08-14

    The transformation and integration of government services, enabled by the use of new technologies such as application servers and Web services, is fundamental to reduce the cost of government and improving service outcomes to citizens. Many core Government information systems comprise applications running on legacy mainframes, databases and transaction processing monitors. As Governments worldwide provide direct access over the Internet to these legacy applications from the general public, they may be exposed to workloads well above the origin design parameters of these back-end systems. This creates a significant risk of high profile failures for Government agencies whose newly integrated systems become overloaded. In this paper we describe how we conducted a performance assessment of a business-critical, Internet-facing Web services that integrated new and legacy systems from two Australian Government agencies. We leveraged prototype tools from our own research along with known techniques in performance modeling. We were able to clearly demonstrate that the existing hardware and software would be adequate to handle the predicted workload for the next financial year. We were also able to do ‘what-if’ analysis and predict how the system can perform with alternative strategies to scale the system. We conclude by summarizing the lessons learnt, including the importance of architecture visibility, benchmarking data quality, and measurement feasibility due to issues of outsourcing, privacy legislation and cross-agency involvement.

  5. Self-assessment: Strategy for higher standards, consistency, and performance

    International Nuclear Information System (INIS)

    Ide, W.E.

    1996-01-01

    In late 1994, Palo Verde operations underwent a transformation from a unitized structure to a single functional unit. It was necessary to build consistency in watchstanding practices and create a shared mission. Because there was a lack of focus on actual plant operations and because personnel were deeply involved with administrative tasks, command and control of evolutions were weak. Improvement was needed. Consistent performance standards have been set for all three operating units. These expectation focus on nuclear, radiological, and industrial safety. Straightforward descriptions of watchstanding and monitoring practices have been provided to all department personnel. The desired professional and leadership qualities for employee conduct have been defined and communicated thoroughly. A healthy and competitive atmosphere developed with the successful implementation of these standards. Overall performance improved. The auxiliary operators demonstrated increased pride and ownership in the performance of their work activities. In addition, their morale improved. Crew teamwork improved as well as the quality of shift briefs. There was a decrease in the noise level and the administrative functions in the control room. The use of self-assessment helped to anchor and define higher and more consistent standards. The proof of Palo Verde's success was evident when an Institute of Nuclear Power Operations finding was turned into a strength within 1 yr

  6. Assessment of gamma camera performance at some Sudanese hospitals

    International Nuclear Information System (INIS)

    Ibrahim, Nour El huda Ibrahim Ali

    2016-05-01

    The study aims to investigate the performance quality of the gamma cameras used in three public hospitals in Sudan. It is widely recognized that the attainment of high standards of efficiency and reliability in the practice of nuclear medicine, as in other specialties based on advanced technology, requires an appropriate quality assurance program. In this study we have focused on four of the main tests in order to assess the performance of the three units in question, such as uniformity, resolution/ linearity, center of rotation, photopeak. The values were within the acceptable range (according to the adopted protocols). Overall performance of the units was acceptable. Although all the results were within the acceptable range, some of them were at border, thus an action of preventive maintenance should be considered. It is noticed that a minor to negligible co-operation exists between the centers experts and /or equipment. The establishment of an external and internal auditing program is recommended. More co-operation between the centers should be considered.(Author)

  7. Sensitivity assessment of fuel performance codes for LOCA accident scenario

    International Nuclear Information System (INIS)

    Abe, Alfredo; Gomes, Daniel; Silva, Antonio Teixeira e; Muniz, Rafael O.R.; Giovedi, Claudia; Martins, Marcelo

    2017-01-01

    FRAPCON code predicts fuel rod performance in LWR (Light Water Reactor) by modeling fuel responses under normal operating conditions and anticipated operational occurrences; FRAPTRAN code is applied for fuel transient under fast transient and accident conditions. The codes are well known and applied for different purposes and one of the use is to address sensitivity analysis considering fuel design parameters associated to fabrication, moreover can address the effect of physical models bias. The objective of this work was to perform an assessment of fuel manufacturing parameters tolerances and fuel models bias using FRAPCON and FRAPTRAN codes for Loss of Coolant Accident (LOCA) scenario. The preliminary analysis considered direct approach taken into account most relevant manufacturing tolerances (lower and upper bounds) related to design parameters and physical models bias without considering their statistical distribution. The simulations were carried out using the data available in the open literature related to the series of LOCA experiment performed at the Halden reactor (specifically IFA-650.5). The manufacturing tolerances associated to design parameters considered in this paper were: enrichment, cladding thickness, pellet diameter, pellet density, and filling gas pressure. The physical models considered were: fuel thermal expansion, fission gas release, fuel swelling, irradiation creep, cladding thermal expansion, cladding corrosion, and cladding hydrogen pickup. The results obtained from sensitivity analysis addressed the impact of manufacturing tolerances and physical models in the fuel cladding burst time observed for the IFA-650.5 experiment. (author)

  8. Performance assessment for the class L-II disposal facility

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This draft radiological performance assessment (PA) for the proposed Class L-II Disposal Facility (CIIDF) on the Oak Ridge Reservation (ORR) has been prepared to demonstrate compliance with the requirements of the US Department of Energy Order 5820.2A. This PA considers the disposal of low-level radioactive wastes (LLW) over the operating life of the facility and the long-term performance of the facility in providing protection to public health and the environment. The performance objectives contained in the order require that the facility be managed to accomplish the following: (1) Protect public health and safety in accordance with standards specified in environmental health orders and other DOE orders. (2) Ensure that external exposure to the waste and concentrations of radioactive material that may be released into surface water, groundwater, soil, plants, and animals results in an effective dose equivalent (EDE) that does not exceed 25 mrem/year to a member of the public. Releases to the atmosphere shall meet the requirements of 40 CFR Pt. 61. Reasonable effort should be made to maintain releases of radioactivity in effluents to the general environment as low as reasonably achievable. (1) Ensure that the committed EDEs received by individual who inadvertently may intrude into the facility after the loss of active institutional control (100 years) will not exceed 100 mrem/year for continuous exposure of 500 mrem for a single acute exposure. (4) Protect groundwater resources, consistent with federal, state, and local requirements.

  9. Assessing Port Governance, Devolution and Terminal Performance in Nigeria

    Directory of Open Access Journals (Sweden)

    D. E. Onwuegbuchunam

    2018-02-01

    Full Text Available Concerns about performance and efficiency in port terminals led many national governments to embark on port reforms. The Federal government of Nigeria, for example, adopted the Landlord port model which brought about concessioning of port terminals to private operators. Despite high investments in terminal facilities by the private terminal operators, there are still complaints about level of service offered to port users. This paper applied key performance indicator metrics and parameters of queuing model in assessing performance of Nigeria’s concessioned port terminals. Data for the study were obtained from terminal level records of cargo and ship handling activities for years 2000 to 2015. Major findings indicate that cargo and vessel throughputs improved after the reforms in the six ports examined. However, much variability was observed in trends in ships’ turnround times across all ports after the concession policy implementation. Additional results from the queuing model analysis suggest that the high ships turnround times observed in some ports are associated to delays in ship operation at the berths. The paper recommends that policy interventions be focused on ship operations at the berths as a step in improving service level in the port terminals.

  10. [Gardner syndrome--parent alienation syndrome (PAS). Diagnosis or family reality?].

    Science.gov (United States)

    Namysłowska, Irena; Heitzman, Janusz; Siewierska, Anna

    2009-01-01

    The authors present characteristics of Parental Alienation Syndrome (PAS) proposed by Gardner as well as data, which may help to differentiate that syndrome with real psychological, physical and sexual abuse. The consequences of Gardner Syndrome for legal decisions in the court cases of child custody and the critique of this syndrome in forensic and psychiatric literature are also discussed, and several questions posed. Authors propose to treat Gardner Syndrome not as as a child disorder but as a specific, dynamic family situation, which occurs sometimes, during divorce and fight about child custody.

  11. Pas de remède miracle Parvenir à une couverture santé universelle ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    26 oct. 2012 ... Pas de remède miracle Parvenir à une couverture santé universelle grâce à des systèmes de santé équitables ... Le Nigeria, qui compte parmi les pays qui affichent les taux les plus élevés de mortalité des mères, des enfants et des nouveau-nés, a fait des soins de santé primaires sa plus grande priorité.

  12. Functional Performance and Associations between Performance Tests and Neurological Assessment Differ in Men and Women with Parkinson’s Disease

    OpenAIRE

    Medijainen, Kadri; Pääsuke, Mati; Lukmann, Aet; Taba, Pille

    2015-01-01

    Background. Neurological assessment of a patient with Parkinson's disease (PD) is expected to reflect upon functional performance. As women are known to report more limitations even for same observed functional performance level, present study was designed to examine whether associations between neurological assessments and functional performance differ across genders. Methods. 14 men and 14 women with PD participated. Functional performance was assessed by measuring walking speeds on 10-mete...

  13. Protective effects of ebselen (Ebs) and para-aminosalicylic acid (PAS) against manganese (Mn)-induced neurotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Marreilha dos Santos, A.P., E-mail: apsantos@ff.ul.pt [I-Med.UL, Department of Toxicology and Food Sciences, Faculty of Pharmacy, University of Lisbon, Lisbon (Portugal); Lucas, Rui L.; Andrade, Vanda; Mateus, M. Luísa [I-Med.UL, Department of Toxicology and Food Sciences, Faculty of Pharmacy, University of Lisbon, Lisbon (Portugal); Milatovic, Dejan; Aschner, Michael [Department of Pediatrics, Vanderbilt University Medical Center, Nashville, TN 37232 (United States); Batoreu, M. Camila [I-Med.UL, Department of Toxicology and Food Sciences, Faculty of Pharmacy, University of Lisbon, Lisbon (Portugal)

    2012-02-01

    Chronic, excessive exposure to manganese (Mn) may induce neurotoxicity and cause an irreversible brain disease, referred to as manganism. Efficacious therapies for the treatment of Mn are lacking, mandating the development of new interventions. The purpose of the present study was to investigate the efficacy of ebselen (Ebs) and para-aminosalicylic acid (PAS) in attenuating the neurotoxic effects of Mn in an in vivo rat model. Exposure biomarkers, inflammatory and oxidative stress biomarkers, as well as behavioral parameters were evaluated. Co-treatment with Mn plus Ebs or Mn plus PAS caused a significant decrease in blood and brain Mn concentrations (compared to rats treated with Mn alone), concomitant with reduced brain E{sub 2} prostaglandin (PGE{sub 2}) and enhanced brain glutathione (GSH) levels, decreased serum prolactin (PRL) levels, and increased ambulation and rearing activities. Taken together, these results establish that both PAS and Ebs are efficacious in reducing Mn body burden, neuroinflammation, oxidative stress and locomotor activity impairments in a rat model of Mn-induced toxicity. -- Highlights: ► The manuscript is unique in its approach to the neurotoxicity of Mn. ► The manuscript incorporates molecular, cellular and functional (behavioral) analyses. ► Both PAS and Ebs are effective in restoring Mn behavioral function. ► Both PAS and Ebs are effective in reducing Mn-induced oxidative stress. ► Both PAS and Ebs led to a decrease in Mn-induced neuro-inflammation.

  14. Protective effects of ebselen (Ebs) and para-aminosalicylic acid (PAS) against manganese (Mn)-induced neurotoxicity

    International Nuclear Information System (INIS)

    Marreilha dos Santos, A.P.; Lucas, Rui L.; Andrade, Vanda; Mateus, M. Luísa; Milatovic, Dejan; Aschner, Michael; Batoreu, M. Camila

    2012-01-01

    Chronic, excessive exposure to manganese (Mn) may induce neurotoxicity and cause an irreversible brain disease, referred to as manganism. Efficacious therapies for the treatment of Mn are lacking, mandating the development of new interventions. The purpose of the present study was to investigate the efficacy of ebselen (Ebs) and para-aminosalicylic acid (PAS) in attenuating the neurotoxic effects of Mn in an in vivo rat model. Exposure biomarkers, inflammatory and oxidative stress biomarkers, as well as behavioral parameters were evaluated. Co-treatment with Mn plus Ebs or Mn plus PAS caused a significant decrease in blood and brain Mn concentrations (compared to rats treated with Mn alone), concomitant with reduced brain E 2 prostaglandin (PGE 2 ) and enhanced brain glutathione (GSH) levels, decreased serum prolactin (PRL) levels, and increased ambulation and rearing activities. Taken together, these results establish that both PAS and Ebs are efficacious in reducing Mn body burden, neuroinflammation, oxidative stress and locomotor activity impairments in a rat model of Mn-induced toxicity. -- Highlights: ► The manuscript is unique in its approach to the neurotoxicity of Mn. ► The manuscript incorporates molecular, cellular and functional (behavioral) analyses. ► Both PAS and Ebs are effective in restoring Mn behavioral function. ► Both PAS and Ebs are effective in reducing Mn-induced oxidative stress. ► Both PAS and Ebs led to a decrease in Mn-induced neuro-inflammation.

  15. A performance assessment methodology for low-level waste facilities

    International Nuclear Information System (INIS)

    Kozak, M.W.; Chu, M.S.Y.; Mattingly, P.A.

    1990-07-01

    A performance assessment methodology has been developed for use by the US Nuclear Regulatory Commission in evaluating license applications for low-level waste disposal facilities. This report provides a summary of background reports on the development of the methodology and an overview of the models and codes selected for the methodology. The overview includes discussions of the philosophy and structure of the methodology and a sequential procedure for applying the methodology. Discussions are provided of models and associated assumptions that are appropriate for each phase of the methodology, the goals of each phase, data required to implement the models, significant sources of uncertainty associated with each phase, and the computer codes used to implement the appropriate models. In addition, a sample demonstration of the methodology is presented for a simple conceptual model. 64 refs., 12 figs., 15 tabs

  16. SITE-94. Site specific base data for the performance assessment

    International Nuclear Information System (INIS)

    Geier, J.; Tiren, S.; Dverstorp, B.; Glynn, P.

    1996-06-01

    This report documents the site specific base data that were available, and the utilization of these data within SITE-94. A brief summary is given of SKB's preliminary site investigations for the Aespoe Hard Rock Laboratory (HRL), which were the main source of site-specific data for SITE-94, and an overview is given of the field methods and instrumentation for the preliminary investigations. A compilation is given of comments concerning the availability and quality of the data for Aespoe, and specific recommendations are given for future site investigations. It was found that the HRL pre-investigations produced a large quantity of data which were, for the most part, of sufficient quality to be valuable for a performance assessment. However, some problems were encountered regarding documentation, procedural consistency, positional information, and storage of the data from the measurements. 77 refs, 4 tabs

  17. Conceptual adsorption models and open issues pertaining to performance assessment

    International Nuclear Information System (INIS)

    Serne, R.J.

    1992-01-01

    Recently several articles have been published that question the appropriateness of the distribution coefficient, Rd, concept to quantify radionuclide migration. Several distinct issues surrounding the modeling of nuclide retardation. The first section defines adsorption terminology and discusses various adsorption processes. The next section describes five commonly used adsorption conceptual models, specifically emphasizing what attributes that affect adsorption are explicitly accommodated in each model. I also review efforts to incorporate each adsorption model into performance assessment transport computer codes. The five adsorption conceptual models are (1) the constant Rd model, (2) the parametric Rd model, (3) isotherm adsorption models, (4) mass action adsorption models, and (5) surface-complexation with electrostatics models. The final section discusses the adequacy of the distribution ratio concept, the adequacy of transport calculations that rely on constant retardation factors and the status of incorporating sophisticated adsorption models into transport codes. 86 refs., 1 fig., 1 tab

  18. Application of fuzzy expert system on LILW performance assessment

    International Nuclear Information System (INIS)

    Lemos, F.L. de; Sullivan, T.

    2002-01-01

    A complete LILW repository performance assessment requires the involvement between several experts in many fields of science. Many sources of uncertainties arise due to complexity of interaction of environmental parameters, lack of data and ignorance, this makes predictive analysis and interpretation difficult. This difficulty in understanding the impact of the ambiguities is even higher when it comes to public and decision makers involvement. Traditional methods of data analysis, while having strong mathematical basis, many times are not adequate to deal with ambiguous data. These ambiguities can be an obstacle to make the results easier to understand and defensible. A methodology of decision making, based on fuzzy logic, can help the interaction between experts, decision makers and the public. This method is the basis of an expert system which can help the analysis of very complex and ambiguous processes. (author)

  19. Sorption data base for performance assessment of radwaste repository

    International Nuclear Information System (INIS)

    Cho, Y.H.; Jung, J.; Lee, J.K.; Hahn, P.S.

    2001-01-01

    Sorption data base (SDB) provides readily available data for the performance assessment of radwaste repository when site-specific data are not available and/or more reference data are needed. The software developed in the Korea Atomic Energy Research Institute (KAERI), SDB-21C, is a graphic user interface (GUI) program that provides efficient and user friendly tools for evaluating the large amount of sorption data. The data base of distribution coefficients compiled in the program contains about 11,000 Nuclear Energy Agency (NEA) data and 2,000 KAERI data up to now while the addition of new data is under progress. Furthermore, the parametric model and its compiled data sets are also included in SDB-21C. (author)

  20. Validation of geotechnical software for repository performance assessment

    International Nuclear Information System (INIS)

    LeGore, T.; Hoover, J.D.; Khaleel, R.; Thornton, E.C.; Anantatmula, R.P.; Lanigan, D.C.

    1989-01-01

    An important step in the characterization of a high level nuclear waste repository is to demonstrate that geotechnical software, used in performance assessment, correctly models validation. There is another type of validation, called software validation. It is based on meeting the requirements of specifications documents (e.g. IEEE specifications) and does not directly address the correctness of the specifications. The process of comparing physical experimental results with the predicted results should incorporate an objective measure of the level of confidence regarding correctness. This paper reports on a methodology developed that allows the experimental uncertainties to be explicitly included in the comparison process. The methodology also allows objective confidence levels to be associated with the software. In the event of a poor comparison, the method also lays the foundation for improving the software

  1. Technology integration performance assessment using lean principles in health care.

    Science.gov (United States)

    Rico, Florentino; Yalcin, Ali; Eikman, Edward A

    2015-01-01

    This study assesses the impact of an automated infusion system (AIS) integration at a positron emission tomography (PET) center based on "lean thinking" principles. The authors propose a systematic measurement system that evaluates improvement in terms of the "8 wastes." This adaptation to the health care context consisted of performance measurement before and after integration of AIS in terms of time, utilization of resources, amount of materials wasted/saved, system variability, distances traveled, and worker strain. The authors' observations indicate that AIS stands to be very effective in a busy PET department, such as the one in Moffitt Cancer Center, owing to its accuracy, pace, and reliability, especially after the necessary adjustments are made to reduce or eliminate the source of errors. This integration must be accompanied by a process reengineering exercise to realize the full potential of AIS in reducing waste and improving patient care and worker satisfaction. © The Author(s) 2014.

  2. Conceptual adsorption models and open issues pertaining to performance assessment

    International Nuclear Information System (INIS)

    Serne, R.J.

    1991-10-01

    Recently several articles have been published that question the appropriateness of the distribution coefficient, Rd, concept to quantify radionuclide migration. Several distinct issues are raised by various critics. In this paper I provide some perspective on issues surrounding the modeling of nuclide retardation. The first section defines adsorption terminology and discusses various adsorption processes. The next section describes five commonly used adsorption conceptual models, specifically emphasizing what attributes that affect adsorption are explicitly accommodated in each model. I also review efforts to incorporate each adsorption model into performance assessment transport computer codes. The five adsorption conceptual models are (1) the constant Rd model, (2) the parametric Rd model, (3) isotherm adsorption models, (4) mass-action adsorption models, and (5) surface-complexation with electrostatics models. The final section discusses the adequacy of the distribution ratio concept, the adequacy of transport calculations that rely on constant retardation factors and the status of incorporating sophisticated adsorption models into transport codes

  3. Analytical performance specifications for external quality assessment - definitions and descriptions.

    Science.gov (United States)

    Jones, Graham R D; Albarede, Stephanie; Kesseler, Dagmar; MacKenzie, Finlay; Mammen, Joy; Pedersen, Morten; Stavelin, Anne; Thelen, Marc; Thomas, Annette; Twomey, Patrick J; Ventura, Emma; Panteghini, Mauro

    2017-06-27

    External Quality Assurance (EQA) is vital to ensure acceptable analytical quality in medical laboratories. A key component of an EQA scheme is an analytical performance specification (APS) for each measurand that a laboratory can use to assess the extent of deviation of the obtained results from the target value. A consensus conference held in Milan in 2014 has proposed three models to set APS and these can be applied to setting APS for EQA. A goal arising from this conference is the harmonisation of EQA APS between different schemes to deliver consistent quality messages to laboratories irrespective of location and the choice of EQA provider. At this time there are wide differences in the APS used in different EQA schemes for the same measurands. Contributing factors to this variation are that the APS in different schemes are established using different criteria, applied to different types of data (e.g. single data points, multiple data points), used for different goals (e.g. improvement of analytical quality; licensing), and with the aim of eliciting different responses from participants. This paper provides recommendations from the European Federation of Laboratory Medicine (EFLM) Task and Finish Group on Performance Specifications for External Quality Assurance Schemes (TFG-APSEQA) and on clear terminology for EQA APS. The recommended terminology covers six elements required to understand APS: 1) a statement on the EQA material matrix and its commutability; 2) the method used to assign the target value; 3) the data set to which APS are applied; 4) the applicable analytical property being assessed (i.e. total error, bias, imprecision, uncertainty); 5) the rationale for the selection of the APS; and 6) the type of the Milan model(s) used to set the APS. The terminology is required for EQA participants and other interested parties to understand the meaning of meeting or not meeting APS.

  4. Assessing the performance of reinforced concrete structures under impact loads

    International Nuclear Information System (INIS)

    Sharma, Akanshu; Reddy, G.R.; Vaze, K.K.; Ozbolt, Josko; Hofmann, J.

    2011-01-01

    Reinforced concrete (RC) structures housing nuclear facilities must qualify against much stringent requirements of operating and accidental loads than conventional structures. One such accidental load that must be considered while assessing the performance of safety related RC structures is impact load. It is known that the behavior of concrete/reinforced concrete structures is strongly influenced by the loading rate. The RC structural members subjected to impact loads behave quite differently as compared to the same subjected to quasi-static loading due to the strain-rate influence on strength, stiffness, and ductility as well as to the activation of inertia forces. Moreover, for concrete structures, which exhibit damage and fracture phenomena, the failure mode and cracking pattern depend significantly on loading rate. In general, there is a tendency that with the increase of loading rate the failure mode changes from mode-I to mixed mode. In order to assess the performance of existing structures against impact loads that may be generated mainly due to man-made accidental conditions, it is important to have models that can realistically predict the impact behavior of concrete structures. The present paper focuses on a relatively new approach for 3D finite element analysis of RC structures under impact loads. The approach uses rate sensitive micro-plane model as constitutive law for concrete, while the strain-rate influence is captured by the activation energy. Inertia forces are implicitly accounted for through dynamic finite element analysis. It is shown with the help of different examples that the approach can very well simulate the behavior of RC structural elements under high rate loading. (author)

  5. Development and validation of a method for the determination of regulated fragrance allergens by High-Performance Liquid Chromatography and Parallel Factor Analysis 2.

    Science.gov (United States)

    Pérez-Outeiral, Jessica; Elcoroaristizabal, Saioa; Amigo, Jose Manuel; Vidal, Maider

    2017-12-01

    This work presents the development and validation of a multivariate method for quantitation of 6 potentially allergenic substances (PAS) related to fragrances by ultrasound-assisted emulsification microextraction coupled with HPLC-DAD and PARAFAC2 in the presence of other 18 PAS. The objective is the extension of a previously proposed univariate method to be able to determine the 24 PAS currently considered as allergens. The suitability of the multivariate approach for the qualitative and quantitative analysis of the analytes is discussed through datasets of increasing complexity, comprising the assessment and validation of the method performance. PARAFAC2 showed to adequately model the data facing up different instrumental and chemical issues, such as co-elution profiles, overlapping spectra, unknown interfering compounds, retention time shifts and baseline drifts. Satisfactory quality parameters of the model performance were obtained (R 2 ≥0.94), as well as meaningful chromatographic and spectral profiles (r≥0.97). Moreover, low errors of prediction in external validation standards (below 15% in most cases) as well as acceptable quantification errors in real spiked samples (recoveries from 82 to 119%) confirmed the suitability of PARAFAC2 for resolution and quantification of the PAS. The combination of the previously proposed univariate approach, for the well-resolved peaks, with the developed multivariate method allows the determination of the 24 regulated PAS. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 4: Uncertainty and sensitivity analyses for 40 CFR 191, Subpart B

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    Before disposing of transuranic radioactive waste in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments (PAs) of the WIPP for the DOE to provide interim guidance while preparing for a final compliance evaluation. This volume of the 1992 PA contains results of uncertainty and sensitivity analyses with respect to the EPA`s Environmental Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). Additional information about the 1992 PA is provided in other volumes. Results of the 1992 uncertainty and sensitivity analyses indicate that, conditional on the modeling assumptions, the choice of parameters selected for sampling, and the assigned parameter-value distributions, the most important parameters for which uncertainty has the potential to affect compliance with 40 CFR 191B are: drilling intensity, intrusion borehole permeability, halite and anhydrite permeabilities, radionuclide solubilities and distribution coefficients, fracture spacing in the Culebra Dolomite Member of the Rustler Formation, porosity of the Culebra, and spatial variability of Culebra transmissivity. Performance with respect to 40 CFR 191B is insensitive to uncertainty in other parameters; however, additional data are needed to confirm that reality lies within the assigned distributions.

  7. Peracetic acid for secondary effluent disinfection: a comprehensive performance assessment.

    Science.gov (United States)

    Antonelli, M; Turolla, A; Mezzanotte, V; Nurizzo, C

    2013-01-01

    The paper is a review of previous research on secondary effluent disinfection by peracetic acid (PAA) integrated with new data about the effect of a preliminary flash-mixing step. The process was studied at bench and pilot scale to assess its performance for discharge in surface water and agricultural reuse (target microorganisms: Escherichia coli and faecal coliform bacteria). The purposes of the research were: (1) determining PAA decay and disinfection kinetics as a function of operating parameters, (2) evaluating PAA suitability as a disinfectant, (3) assessing long-term disinfection efficiency, (4) investigating disinfected effluent biological toxicity on some aquatic indicator organisms (Vibrio fischeri, Daphnia magna and Selenastrum capricornutum), (5) comparing PAA with conventional disinfectants (sodium hypochlorite, UV irradiation). PAA disinfection was capable of complying with Italian regulations on reuse (10 CFU/100 mL for E. coli) and was competitive with benchmarks. No regrowth phenomena were observed, as long as needed for agricultural reuse (29 h after disinfection), even at negligible concentrations of residual disinfectant. The toxic effect of PAA on the aquatic environment was due to the residual disinfectant in the water, rather than to chemical modification of the effluent.

  8. Standardized assessment of infrared thermographic fever screening system performance

    Science.gov (United States)

    Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-03-01

    Thermal modalities represent the only currently viable mass fever screening approach for outbreaks of infectious disease pandemics such as Ebola and SARS. Non-contact infrared thermometers (NCITs) and infrared thermographs (IRTs) have been previously used for mass fever screening in transportation hubs such as airports to reduce the spread of disease. While NCITs remain a more popular choice for fever screening in the field and at fixed locations, there has been increasing evidence in the literature that IRTs can provide greater accuracy in estimating core body temperature if appropriate measurement practices are applied - including the use of technically suitable thermographs. Therefore, the purpose of this study was to develop a battery of evaluation test methods for standardized, objective and quantitative assessment of thermograph performance characteristics critical to assessing suitability for clinical use. These factors include stability, drift, uniformity, minimum resolvable temperature difference, and accuracy. Two commercial IRT models were characterized. An external temperature reference source with high temperature accuracy was utilized as part of the screening thermograph. Results showed that both IRTs are relatively accurate and stable (<1% error of reading with stability of +/-0.05°C). Overall, results of this study may facilitate development of standardized consensus test methods to enable consistent and accurate use of IRTs for fever screening.

  9. A novel source of MeV positron bunches driven by energetic protons for PAS application

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Zongquan, E-mail: tqq1123@mail.ustc.edu.cn [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Xu, Wenzhen; Liu, Yanfen; Xiao, Ran; Kong, Wei [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Ye, Bangjiao, E-mail: bjye@ustc.edu.cn [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2014-11-01

    This paper proposes a novel methodology of MeV positrons generation for PAS application. Feasibility of this proposal analyzed by G4Beamline and Transport have shown reasonable success. Using 2 Hz, 1.6 GeV, 100 ns and 1.5 μC/bunch proton bunches for bombarding a graphite target, about 100 ns e{sup +} bunches are generated. Quasi-monochromatic positrons in the range of 1–10 MeV included in these bunches have a flux of >10{sup 7}/s, peak brightness of 10{sup 14}/s. A magnetic-confinement beamline is utilized to transport the positrons and a “Fast Beam Chopper” is unprecedentedly extended to chop those relativistic bunches. The positron beam can be finally characterized by the energy range of 1–10 MeV and bunch width from one hundred ps up to 1 ns. Such ultrashort bunches can be useful in tomography-type positron annihilation spectroscopy (PAS) as well as other applications.

  10. A novel source of MeV positron bunches driven by energetic protons for PAS application

    Science.gov (United States)

    Tan, Zongquan; Xu, Wenzhen; Liu, Yanfen; Xiao, Ran; Kong, Wei; Ye, Bangjiao

    2014-11-01

    This paper proposes a novel methodology of MeV positrons generation for PAS application. Feasibility of this proposal analyzed by G4Beamline and Transport have shown reasonable success. Using 2 Hz, 1.6 GeV, 100 ns and 1.5 μC/bunch proton bunches for bombarding a graphite target, about 100 ns e+ bunches are generated. Quasi-monochromatic positrons in the range of 1-10 MeV included in these bunches have a flux of >107/s, peak brightness of 1014/s. A magnetic-confinement beamline is utilized to transport the positrons and a "Fast Beam Chopper" is unprecedentedly extended to chop those relativistic bunches. The positron beam can be finally characterized by the energy range of 1-10 MeV and bunch width from one hundred ps up to 1 ns. Such ultrashort bunches can be useful in tomography-type positron annihilation spectroscopy (PAS) as well as other applications.

  11. Evropski zeleni pas – narava ne pozna meja. Od železne zavese do popkovine Evrope.

    Directory of Open Access Journals (Sweden)

    Liana Geidezis

    2004-01-01

    Full Text Available Od Barentsovega do Črnega morja je železna zavesa Evropo delila skoraj štirideset let. Bila je politična, ideološka in fizična ovira, še najbolj izrazito v Nemčiji. Čeprav je bila docela nečloveška, je omogočila naravi premor: narava se je razbohotila in razvilo se je nekaj izjemno redkega v intenzivno uporabljeni krajini – t. i. zeleni pas. Od padca železne zavese leta 1989, poteka prek Evrope popkovina habitatov, dolga skoraj 8.500 km. Z izhodišči v projektu Green Belt Germany, nastalem na pobudo BUND, se je razvil projekt Zeleni pas Evrope ali Green Belt Europe. Lahko postane hrbtenica ekološkega omrežja, ki bo globalni simbol čezmejnega sodelovanja in ohranjanja narave ter vzdržnega razvoja. Še več, povezuje ljudi in kaže, da ima lahko povečana Evropska unija poleg kulturne tudi skupno naravno dediščino. To je enkratna priložnost za premagovanje starih meja in ovir med vzhodom in zahodom – živo znamenje skupne rasti v Evropi.

  12. Inhibitory PAS domain protein is a negative regulator of hypoxia-inducible gene expression

    Science.gov (United States)

    Makino, Yuichi; Cao, Renhai; Svensson, Kristian; Bertilsson, Göran; Asman, Mikael; Tanaka, Hirotoshi; Cao, Yihai; Berkenstam, Anders; Poellinger, Lorenz

    2001-11-01

    Alteration of gene expression is a crucial component of adaptive responses to hypoxia. These responses are mediated by hypoxia-inducible transcription factors (HIFs). Here we describe an inhibitory PAS (Per/Arnt/Sim) domain protein, IPAS, which is a basic helix-loop-helix (bHLH)/PAS protein structurally related to HIFs. IPAS contains no endogenous transactivation function but demonstrates dominant negative regulation of HIF-mediated control of gene expression. Ectopic expression of IPAS in hepatoma cells selectively impairs induction of genes involved in adaptation to a hypoxic environment, notably the vascular endothelial growth factor (VEGF) gene, and results in retarded tumour growth and tumour vascular density in vivo. In mice, IPAS was predominantly expressed in Purkinje cells of the cerebellum and in corneal epithelium of the eye. Expression of IPAS in the cornea correlates with low levels of expression of the VEGF gene under hypoxic conditions. Application of an IPAS antisense oligonucleotide to the mouse cornea induced angiogenesis under normal oxygen conditions, and demonstrated hypoxia-dependent induction of VEGF gene expression in hypoxic corneal cells. These results indicate a previously unknown mechanism for negative regulation of angiogenesis and maintenance of an avascular phenotype.

  13. Meeting with Jean-Yves Le Meur, author of "Faux Pas"

    CERN Multimedia

    2008-01-01

    A CERN engineer and an accomplished sportsman, Jean-Yves Le Meur (IT Department) has recently published his first book "Faux pas". Meet him and hear about his exceptional life on 23 April 2008 in the Globe. An accident cost him his legs when he was young, and it was sheer force of character and a passion for the mountains that carried Jean-Yves Le Meur, with one artificial leg and crutches to stay upright, to the very summit of the Mont-Blanc. In his book, Jean-Yves, a computer engineer at CERN, recounts with detachment his personal battle to win back his life and make this impossible ascent. "Faux Pas" depicts a series of encounters and people, and recreates the extreme emotions of a man who reconstructed his life and pushed himself beyond his limits. It is a moving personal account, whose message is universal. The question-and-answer session with the author will be preceded by the projection of "4810M, CAHIN-CAHA",...

  14. PAs and NPs in an emergency room-linked acute care clinic.

    Science.gov (United States)

    Currey, C J

    1984-12-01

    The use of hospital emergency rooms for nonurgent care during evenings hours often strains medical resources and may affect the quality of emergency care. One facility's effective use of an after-hours acute care clinic staffed by PAs and NPs to divert nonurgent problems away from its emergency room is outlined. PAs and NPs work during peak demand hours (evenings and weekends) under the supervision of an emergency room physician, and receive supplementary support from other emergency room personnel. Incoming patients are referred to the emergency room or acute care clinic, depending on the nature of their problems. Acute care clinic patients are then treated by the PA or NP and either released or referred to an emergency room physician, if their conditions warrant additional treatment. As a result, use of the acute care clinic has greatly reduced the amount of non-urgent medical treatment in the emergency room and has provided other advantages to both patients and staff as well. These advantages and the encouraging statistics following six months of the clinic's operation are discussed.

  15. Waste package performance assessment for the Yucca Mountain Project

    International Nuclear Information System (INIS)

    O'Connell, W.J.; Lappa, D.A.; Thatcher, R.M.

    1989-02-01

    We completed a first cycle of model development from a specification to a computer program, PANDORA-1, for long-term performance assessment of waste packages. The model for one waste package at a time incorporates processes specific to the unsaturated environment at the proposed Yucca Mountain, NV, site. PANDORA-1 models the most likely processes and several modes of waste alteration and release. The development identified information needs for future models; many processes, local details, and combinations will have to be examined. Integration of ensemble performance and quantification of uncertainties are modeling steps at higher aggregation. Methodologies for these steps include sampling, which is well studied; we have focused on several open questions. We can now calculate the amount of variance reduction available from Latin hypercube sampling; it is a limited reduction. A new method, controlled sampling, provides substantial variance reduction for a broad range of model functions. An uncertainty analysis test-bed program compares the new with old sampling methods. 7 refs., 1 tab

  16. Approach to geologic repository post closure system performance assessment

    International Nuclear Information System (INIS)

    Pahwa, S.B.; Felton, W.; Duguid, J.O.

    1992-01-01

    An essential part of the license application for a geologic repository will be the demonstration of compliance with the standards set by the Environmental Protection Agency. The performance assessments that produce the demonstration must rely on models of various levels of detail. The most detailed of these models are needed for understanding thoroughly the complex physical and chemical processes affecting the behavior of the system. For studying the behavior of major components of the system, less detailed models are often useful. For predicting the behavior of the total system, models of a third kind may be needed. These models must cover all the important processes that contribute to the behavior of the system, because they must estimate the behavior under all significant conditions for 10,000 years. In addition, however, computer codes that embody these models must calculate very rapidly because of the EPA standard's requirement for probabilistic estimates, which will be produced by sampling thousands of times from probability distributions of parameters. For this reason, the total-system models must be less complex than the detailed-process and subsystem models. The total-system performance is evaluated through modeling of the following components: Radionuclide release from the engineered-barrier system. Fluid flow in the geologic units. Radionuclide transport to the accessible environment. Radionuclide release to the accessible environment and dose to man

  17. Uncertainty evaluation methods for waste package performance assessment

    International Nuclear Information System (INIS)

    Wu, Y.T.; Nair, P.K.; Journel, A.G.; Abramson, L.R.

    1991-01-01

    This report identifies and investigates methodologies to deal with uncertainties in assessing high-level nuclear waste package performance. Four uncertainty evaluation methods (probability-distribution approach, bounding approach, expert judgment, and sensitivity analysis) are suggested as the elements of a methodology that, without either diminishing or enhancing the input uncertainties, can evaluate performance uncertainty. Such a methodology can also help identify critical inputs as a guide to reducing uncertainty so as to provide reasonable assurance that the risk objectives are met. This report examines the current qualitative waste containment regulation and shows how, in conjunction with the identified uncertainty evaluation methodology, a framework for a quantitative probability-based rule can be developed that takes account of the uncertainties. Current US Nuclear Regulatory Commission (NRC) regulation requires that the waste packages provide ''substantially complete containment'' (SCC) during the containment period. The term ''SCC'' is ambiguous and subject to interpretation. This report, together with an accompanying report that describes the technical considerations that must be addressed to satisfy high-level waste containment requirements, provides a basis for a third report to develop recommendations for regulatory uncertainty reduction in the ''containment''requirement of 10 CFR Part 60. 25 refs., 3 figs., 2 tabs

  18. Scramjet Performance Assessment Using Water Absorption Diagnostics (U)

    Science.gov (United States)

    Cavolowsky, John A.; Loomis, Mark P.; Deiwert, George

    1995-01-01

    balance measuring thrust and integrated pressure measurements along the length of the nozzle. Assessment of its value as a combustor performance evaluation tool will be conducted.

  19. Sorption databases for increasing confidence in performance assessment - 16053

    International Nuclear Information System (INIS)

    Richter, Anke; Brendler, Vinzenz; Nebelung, Cordula; Payne, Timothy E.; Brasser, Thomas

    2009-01-01

    World-wide activities focus on the remediation of radioactively contaminated sites. One common aim is to deliver a more profound chemical base for risk assessment, namely all those physico-chemical phenomena governing the contamination plume development in time and space. Coupled transport codes able to tackle this challenge have to simplify the resulting very complex reaction pattern. To do so in an adequate way requires extending the knowledge about retardation and mobilisation phenomena and the underlying basic processes and interactions (e.g. physisorption, chemisorption, surface precipitation). Interactions at the solid-liquid interface can be described by complementary approaches, the empirical K d concept and the mechanistic Surface Complexation Models (SCM). K d 's are used by most reactive transport and risk assessment codes due to the straightforward numerics involved. In addition, the K d concept is often the only feasible option for complex solid phases. However, the K d concept is a rather simplistic approach. Many very different basic physicochemical phenomena are subsumed in just one conditional parameter. Therefore, extrapolating K d values may yield very large uncertainties. SCM account adsorption of ions on surface sites as complexation reaction comparable to complexation in solution. The electrical charge at the surface is determined by the chemical reactions of the mineral functional groups, including acid-base reactions and formation of ion pairs and coordinative complexes. The required parameters are site-independent and applicable despite large variations in geochemical conditions. This presents a high potential to increase confidence in safety analysis and risk assessment studies (performance assessment). The mechanistic description of sorption processes with SCM allows a thermodynamically consistent calculation of the species distribution between liquid and solid phase combined with more reliable inter- and extrapolations. However, this

  20. A Control Variate Method for Probabilistic Performance Assessment. Improved Estimates for Mean Performance Quantities of Interest

    Energy Technology Data Exchange (ETDEWEB)

    MacKinnon, Robert J.; Kuhlman, Kristopher L

    2016-05-01

    We present a method of control variates for calculating improved estimates for mean performance quantities of interest, E(PQI) , computed from Monte Carlo probabilistic simulations. An example of a PQI is the concentration of a contaminant at a particular location in a problem domain computed from simulations of transport in porous media. To simplify the presentation, the method is described in the setting of a one- dimensional elliptical model problem involving a single uncertain parameter represented by a probability distribution. The approach can be easily implemented for more complex problems involving multiple uncertain parameters and in particular for application to probabilistic performance assessment of deep geologic nuclear waste repository systems. Numerical results indicate the method can produce estimates of E(PQI)having superior accuracy on coarser meshes and reduce the required number of simulations needed to achieve an acceptable estimate.

  1. Performance assessment instrument to assess the senior high students' psychomotor for the salt hydrolysis material

    Science.gov (United States)

    Nahadi, Firman, Harry; Yulina, Erlis

    2016-02-01

    The purposes of this study were to develop a performance assessment instrument for assessing the competence of psychomotor high school students on salt hydrolysis concepts. The design used in this study was the Research & Development which consists of three phases: development, testing and application of instruments. Subjects in this study were high school students in class XI science, which amounts to 93 students. In the development phase, seven validators validated 17 tasks instrument. In the test phase, we divided 19 students into three-part different times to conduct performance test in salt hydrolysis lab work and observed by six raters. The first, the second, and the third groups recpectively consist of five, six, and eight students. In the application phase, two raters observed the performance of 74 students in the salt hydrolysis lab work in several times. The results showed that 16 of 17 tasks of performance assessment instrument developed can be stated to be valid with CVR value of 1,00 and 0,714. While, the rest was not valid with CVR value was 0.429, below the critical value (0.622). In the test phase, reliability value of instrument obtained were 0,951 for the five-student group, 0,806 for the six-student group and 0,743 for the eight-student group. From the interviews, teachers strongly agree with the performance instrument developed. They stated that the instrument was feasible to use for maximum number of students were six in a single observation.

  2. 2013 Annual Summary Report for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada National Security Site, Nye County, Nevada; Review of the Performance Assessments and Composite Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Shott, Gregory [NSTec

    2014-03-01

    The Maintenance Plan for the Performance Assessments and Composite Analyses for the Area 3 and Area 5 Radioactive Waste Management Sites at the Nevada Test Site (National Security Technologies, LLC 2007a) requires an annual review to assess the adequacy of the performance assessments (PAs) and composite analyses (CAs), with the results submitted to the U.S. Department of Energy (DOE) Office of Environmental Management. The Disposal Authorization Statements for the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) also require that such reviews be made and that secondary or minor unresolved issues be tracked and addressed as part of the maintenance plan (DOE 1999a, 2000). The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office performed an annual review of the Area 3 and Area 5 RWMS PAs and CAs for fiscal year (FY) 2013. This annual summary report presents data and conclusions from the FY 2013 review, and determines the adequacy of the PAs and CAs. Operational factors (e.g., waste forms and containers, facility design, and waste receipts), closure plans, monitoring results, and research and development (R&D) activities were reviewed to determine the adequacy of the PAs. Likewise, the environmental restoration activities at the Nevada National Security Site (NNSS) relevant to the sources of residual radioactive material that are considered in the CAs, the land-use planning, and the results of the environmental monitoring and R&D activities were reviewed to determine the adequacy of the CAs. Important developments in FY 2013 include the following: • Development of a new Area 5 RWMS closure inventory estimate based on disposals through FY 2013 • Evaluation of new or revised waste streams by special analysis • Development of version 4.115 of the Area 5 RWMS GoldSim PA/CA model The Area 3 RWMS has been in inactive status since July 1, 2006, with the last shipment received in April 2006. The FY 2013 review of operations

  3. Study on the barrier performance of molten solidified waste (I). Review of the performance assessment research

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Toshikatsu; Sakamoto, Yoshiaki; Nakayama, Shinichi; Yamaguchi, Tetsuji; Ogawa, Hiromichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-02-01

    Application of melting technique is thought as one of the effective methods to treatment of the waste from the view point of its homogeneity and waste volume reduction. Solidified products by melting are expected as potential candidates of engineered barrier in a repository due to the good properties for their stabilization of radionuclides and hazardous elements. However, the methodology of performance evaluation has not been estimated so far. In this report, a literature survey on the properties of molten solidified waste was performed. It is clarified that the leachability of waste elements such as Co or Sr in molten waste form would be controlled by the corrosion behaviors of iron or silica which are the matrix elements of the waste form. While, no investigations into the durability of waste form have performed so far. Also noticed that the research items on performance evaluation such as the leachability for long-lived radionuclides and durability of waste form would be necessary for the long-term barrier assessment on the disposal. (author)

  4. Enhanced Performance Assessment System (EPAS) for carbon sequestration.

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yifeng; Sun, Amy Cha-Tien; McNeish, Jerry A. (Sandia National Laboratories, Livermore, CA); Dewers, Thomas A.; Hadgu, Teklu; Jove-Colon, Carlos F.

    2010-09-01

    Carbon capture and sequestration (CCS) is an option to mitigate impacts of atmospheric carbon emission. Numerous factors are important in determining the overall effectiveness of long-term geologic storage of carbon, including leakage rates, volume of storage available, and system costs. Recent efforts have been made to apply an existing probabilistic performance assessment (PA) methodology developed for deep nuclear waste geologic repositories to evaluate the effectiveness of subsurface carbon storage (Viswanathan et al., 2008; Stauffer et al., 2009). However, to address the most pressing management, regulatory, and scientific concerns with subsurface carbon storage (CS), the existing PA methodology and tools must be enhanced and upgraded. For example, in the evaluation of a nuclear waste repository, a PA model is essentially a forward model that samples input parameters and runs multiple realizations to estimate future consequences and determine important parameters driving the system performance. In the CS evaluation, however, a PA model must be able to run both forward and inverse calculations to support optimization of CO{sub 2} injection and real-time site monitoring as an integral part of the system design and operation. The monitoring data must be continually fused into the PA model through model inversion and parameter estimation. Model calculations will in turn guide the design of optimal monitoring and carbon-injection strategies (e.g., in terms of monitoring techniques, locations, and time intervals). Under the support of Laboratory-Directed Research & Development (LDRD), a late-start LDRD project was initiated in June of Fiscal Year 2010 to explore the concept of an enhanced performance assessment system (EPAS) for carbon sequestration and storage. In spite of the tight time constraints, significant progress has been made on the project: (1) Following the general PA methodology, a preliminary Feature, Event, and Process (FEP) analysis was performed for

  5. An Approach for Performance Assessments of Extravehicular Activity Gloves

    Science.gov (United States)

    Aitchison, Lindsay; Benosn, Elizabeth

    2014-01-01

    The Space Suit Assembly (SSA) Development Team at NASA Johnson Space Center has invested heavily in the advancement of rear-entry planetary exploration suit design but largely deferred development of extravehicular activity (EVA) glove designs, and accepted the risk of using the current flight gloves, Phase VI, for unique mission scenarios outside the Space Shuttle and International Space Station (ISS) Program realm of experience. However, as design reference missions mature, the risks of using heritage hardware have highlighted the need for developing robust new glove technologies. To address the technology gap, the NASA Game-Changing Technology group provided start-up funding for the High Performance EVA Glove (HPEG) Project in the spring of 2012. The overarching goal of the HPEG Project is to develop a robust glove design that increases human performance during EVA and creates pathway for future implementation of emergent technologies, with specific aims of increasing pressurized mobility to 60% of barehanded capability, increasing the durability by 100%, and decreasing the potential of gloves to cause injury during use. The HPEG Project focused initial efforts on identifying potential new technologies and benchmarking the performance of current state of the art gloves to identify trends in design and fit leading to establish standards and metrics against which emerging technologies can be assessed at both the component and assembly levels. The first of the benchmarking tests evaluated the quantitative mobility performance and subjective fit of two sets of prototype EVA gloves developed ILC Dover and David Clark Company as compared to the Phase VI. Both companies were asked to design and fabricate gloves to the same set of NASA provided hand measurements (which corresponded to a single size of Phase Vi glove) and focus their efforts on improving mobility in the metacarpal phalangeal and carpometacarpal joints. Four test subjects representing the design-to hand

  6. Exploratory analysis of normative performance on the UCSD Performance-Based Skills Assessment-Brief.

    Science.gov (United States)

    Vella, Lea; Patterson, Thomas L; Harvey, Philip D; McClure, Margaret McNamara; Mausbach, Brent T; Taylor, Michael J; Twamley, Elizabeth W

    2017-10-01

    The UCSD Performance-Based Skills Assessment (UPSA) is a performance-based measure of functional capacity. The brief, two-domain (finance and communication ability) version of the assessment (UPSA-B) is now widely used in both clinical research and treatment trials. To date, research has not examined possible demographic-UPSA-B relationships within a non-psychiatric population. We aimed to produce and describe preliminary normative scores for the UPSA-B over a full range of ages and educational attainment. The finance and communication subscales of the UPSA were administered to 190 healthy participants in the context of three separate studies. These data were combined to examine the effects of age, sex, and educational attainment on the UPSA-B domain and total scores. Fractional polynomial regression was used to compute demographically-corrected T-scores for the UPSA-B total score, and percentile rank conversion was used for the two subscales. Age and education both had significant non-linear effects on the UPSA-B total score. The finance subscale was significantly related to both gender and years of education, whereas the communication subscale was not significantly related to any of the demographic characteristics. Demographically corrected T-scores and percentile ranks for UPSA-B scores are now available for use in clinical research. Published by Elsevier B.V.

  7. Assessment of calcium scoring performance in cardiac computed tomography

    International Nuclear Information System (INIS)

    Ulzheimer, Stefan; Kalender, Willi A.

    2003-01-01

    Electron beam tomography (EBT) has been used for cardiac diagnosis and the quantitative assessment of coronary calcium since the late 1980s. The introduction of mechanical multi-slice spiral CT (MSCT) scanners with shorter rotation times opened new possibilities of cardiac imaging with conventional CT scanners. The purpose of this work was to qualitatively and quantitatively evaluate the performance for EBT and MSCT for the task of coronary artery calcium imaging as a function of acquisition protocol, heart rate, spiral reconstruction algorithm (where applicable) and calcium scoring method. A cardiac CT semi-anthropomorphic phantom was designed and manufactured for the investigation of all relevant image quality parameters in cardiac CT. This phantom includes various test objects, some of which can be moved within the anthropomorphic phantom in a manner that mimics realistic heart motion. These tools were used to qualitatively and quantitatively demonstrate the accuracy of coronary calcium imaging using typical protocols for an electron beam (Evolution C-150XP, Imatron, South San Francisco, Calif.) and a 0.5-s four-slice spiral CT scanner (Sensation 4, Siemens, Erlangen, Germany). A special focus was put on the method of quantifying coronary calcium, and three scoring systems were evaluated (Agatston, volume, and mass scoring). Good reproducibility in coronary calcium scoring is always the result of a combination of high temporal and spatial resolution; consequently, thin-slice protocols in combination with retrospective gating on MSCT scanners yielded the best results. The Agatston score was found to be the least reproducible scoring method. The hydroxyapatite mass, being better reproducible and comparable on different scanners and being a physical quantitative measure, appears to be the method of choice for future clinical studies. The hydroxyapatite mass is highly correlated to the Agatston score. The introduced phantoms can be used to quantitatively assess the

  8. Key performance indicators for the assessment of pediatric pharmacotherapeutic guidance.

    Science.gov (United States)

    Barrett, Jeffrey S; Patel, Dimple; Jayaraman, Bhuvana; Narayan, Mahesh; Zuppa, Athena

    2008-07-01

    Given the paucity of actual guidance provided for managing pediatric drug therapy, prescribing caregivers must be able to draw on the limited published information in pediatrics and/or guidance provided in adults with some account for expected pediatric response. Guidance for managing drug therapy in children is clearly desirable. Our objectives were to construct key performance indicators (KPIs) for pediatric pharmacotherapy guidance to identify drugs where pharmacotherapy guidance would be most beneficial. A pilot survey to assess variation in caregiver appreciation for pediatric dosing guidance has also been constructed to provide a complementary subjective assessment. Three KPI categories, drug utilization (based on hospital admission and billing data collected from 2001 through 2006), medical need, and guidance outcome value along with a KPI composite score have been proposed. Low scores are favored with respect to prioritization for pharmacotherapy guidance. The pilot survey consisted of 15 questions to assess 1) physician knowledge regarding dosing guidance, 2) attitudes toward dose modification and patient individualization, 3) the accessibility, ease of use and appropriateness of existing data stores, and 4) frequency of dosing modification, consultation of dosing compendiums and estimate of success rate in dosing guidance. Pilot results suggest that dosing guidance is generally viewed as important and that the existing resources are insufficient to guide recommendations for all drugs. While the majority of respondents check more than one resource less than 25% of the time, at least 25% of the respondents check more than one resource 25-50% of the time. The majority viewed the relevance of dosing guidance very important to the management of drug therapy. The questionnaire is being extended to the primary care centers, the Kids First Network and specialty care centers. Results will guide the development of decision support systems (DSS) that provide patient

  9. Assessing the performance of renewable electricity support instruments

    International Nuclear Information System (INIS)

    Verbruggen, Aviel; Lauber, Volkmar

    2012-01-01

    The performance of feed-in tariffs and tradable certificates is assessed on criteria of efficacy, efficiency, equity and institutional feasibility. In the early stage of transition to an energy system based entirely on renewable energy supplies, renewable electricity can only thrive if support takes into account the specific technical, economic and political problems which result from embedding this electricity in conventional power systems whose technology, organizational structure, environmental responsibility and general mission differ profoundly from the emerging, renewable-based system. Support schemes need to capture the diversity of power supplies, the variable nature of some renewable supplies, and their different attributes for the purposes of public policy. They must take into account the variety of generators – including small, decentralized generation – emerging in a renewable-based system, and the new relationships between generators and customers. Renewable energy policies need a clear point of reference: because the incumbent power systems are not sustainable they must adapt to the requirements of the renewable ones, not the other way round. Incumbent systems carry the responsibility of paying the transition, something that corresponds best with the polluter pays principle. - Highlights: ► Present power systems must adapt to the requirements of growing renewable ones, not the opposite. ► Well performing support systems capture the diversity of renewable sources and technologies. ► Feed-in Tariffs are superior in addressing the renewables' diversity and in promoting innovation. ► Feed-in Tariffs put transition burdens on incumbents and stimulate independent producers.

  10. Assessment of causes for degrading fuel performance at Darlington NGS

    International Nuclear Information System (INIS)

    Judah, J.; Goodchild, S.

    2013-01-01

    Fuel performance at the Darlington nuclear generating station has historically been excellent. Until recently, the majority of these few fuel defects have been attributed to fretting by heat transport system debris. The minority have been linked to manufacturing issues. Recently, Darlington has experienced an increase in the number of fuel defects. Although the defect rate remains low with respect to industry standards, this defect experience is considered to be unacceptable given current industry expectations and the OPG zero defect policy. Nine fuel defects have been discharged since 2007 from the four Darlington reactors. This represents a fuel defect rate of just 0.35 defects per year per reactor. At the time of this writing three additional defects are suspected to be in core. Although a definitive defect cause has yet to be identified, these fuel performance issues appear to be due to the coincidental degradation of manufacturing and operational factors, thereby decreasing the margins to fuel failure due to fuelling power ramps. All of the confirmed defected bundles have been long bundles and all experienced a relatively high power ramp when shifted from Position 2 to Position 6. High bundle uranium masses and low internal clearances are thought to be significant contributing factors. Bundle burnups at the time of the power ramps were low and these bundles were not identified by existing power ramp defect predictive tools. Our assessment has resulted in a number of recommendations which are designed to mitigate these adverse conditions by restoring the margins to power ramp failures. These recommendations impact broadly across a number of organizations including reactor physics, fuel design, fuel manufacturing, reactor design, inspections and PIE. (author)

  11. Judicial Performance Review in Arizona: A Critical Assessment

    Directory of Open Access Journals (Sweden)

    Rebecca White Berch

    2014-12-01

    Full Text Available Judicial performance evaluations are a relatively new tool for assessing judges and providing information to voters to help them determine whether to retain judges in contested or retention elections. Arizona implemented its judicial evaluation program about 20 years ago, and since that time, the state has continually strived to improve its process. The result is that today Arizona has one of the most progressive and comprehensive judicial performance evaluation programs in the United States. This article takes a critical look at the strengths and weaknesses of Arizona’s program, keeping in mind two key values that the system seeks to protect: judicial accountability and judicial independence. Las evaluaciones del rendimiento judicial son una herramienta relativamente nueva para evaluar a los jueces y ofrecer información a los votantes, que les ayude a decidir si quieren reelegir a los jueces en las elecciones. Arizona implementó su programa de evaluación judicial hace unos 20 años, y desde ese momento, el Estado se ha esforzado continuamente en mejorar el proceso. El resultado es que hoy en día, Arizona tiene uno de los programas de evaluación del rendimiento judicial más progresistas e integrales de los Estados Unidos. Este artículo ofrece una mirada crítica a las fortalezas y debilidades del programa de Arizona, teniendo en cuenta dos valores clave que el sistema trata de proteger: la responsabilidad judicial y la independencia judicial. DOWNLOAD THIS PAPER FROM SSRN: http://ssrn.com/abstract=2533868

  12. Performance assessment of a data processing chain for THz imaging

    Science.gov (United States)

    Catapano, Ilaria; Ludeno, Giovanni; Soldovieri, Francesco

    2017-04-01

    Nowadays, TeraHertz (THz) imaging is deserving huge attention as very high resolution diagnostic tool in many applicative fields, among which security, cultural heritage, material characterization and civil engineering diagnostics. This widespread use of THz waves is due to their non-ionizing nature, their capability of penetrating into non-metallic opaque materials, as well as to the technological advances, which have allowed the commercialization of compact, flexible and portable systems. However, the effectiveness of THz imaging depends strongly on the adopted data processing aimed at improving the imaging performance of the hardware device. In particular, data processing is required to mitigate detrimental and unavoidable effects like noise, signal attenuation, as well as to correct the sample surface topography. With respect to data processing, we have proposed recently a strategy involving three different steps aimed at reducing noise, filtering out undesired signal introduced by the adopted THz system and performing surface topography correction [1]. The first step regards noise filtering and exploits a procedure based on the Singular Value Decomposition (SVD) [2] of the data matrix, which does not require knowledge of noise level and it does not involve the use of a reference signal. The second step aims at removing the undesired signal that we have experienced to be introduced by the adopted Z-Omega Fiber-Coupled Terahertz Time Domain (FICO) system. Indeed, when the system works in a high-speed mode, an undesired low amplitude peak occurs always at the same time instant from the beginning of the observation time window and needs to be removed from the useful data matrix in order to avoid a wrong interpretation of the imaging results. The third step of the considered data processing chain is a topographic correction, which needs in order to image properly the samples surface and its inner structure. Such a procedure performs an automatic alignment of the

  13. Detailed Performance Assessment for the ITER ECE Diagnostic

    Science.gov (United States)

    Rowan, W.; Austin, M.; Houshmandyar, S.; Phillips, P.; Beno, J.; Bryant, A.; Ouroua, A.; Weeks, D.; Hubbard, A.; Taylor, G.

    2017-10-01

    One of the primary diagnostics for electron temperature (Te) measurement on ITER is based on the detection of electron cyclotron emission (ECE) Here we describe the predicted performance of the newly completed ECE diagnostic design by quantitatively following the emission from the plasma to the instruments and including the calibration method to assess accuracy. Operation of the diagnostic at 5.3 T is the main interest here but critical features of the emission spectra for 2.65 T and 1.8 T will be described. ECE will be collected by two very similar optical systems: one a radial view, the other an oblique view. Both measurements are used for Te while the oblique view also allows detection of non-thermal distortion in the electron distribution. An in-vacuum calibration source is included in the front end of each view to calibrate out the effect of any degradation of in-vessel optics. Following collection, the emission is split into orthogonal polarizations and transmitted to the detection instruments via waveguides filled with dry nitrogen, a choice that simplifies construction and analysis. Near the instruments, a switchyard is used to select which polarization and view is detected by each instrument. The design for the radiometer used for 5.3 T will be described in detail. Supported by PPPL/US-DA via subcontract S013464-H to UT Austin.

  14. Regulatory basis for the Waste Isolation Pilot Plant performance assessment

    International Nuclear Information System (INIS)

    Howard, Bryan A.; Crawford, M.B.; Galson, D.A.; Marietta, Melvin G.

    2000-01-01

    The Waste Isolation Pilot Plant (WIPP) is the first operational repository designed for the safe disposal of transuranic (TRU) radioactive waste from the defense programs of the US Department of Energy (DOE). The US Environmental Protection Agency (EPA) is responsible for certifications and regulation of the WIPP facility for the radioactive components of the waste. The EPA has promulgated general radioactive waste disposal standards at 40 CFR Part 191. and WIPP-specific criteria to implement and interpret the generic disposal standards at 40 CFR Part 194. In October 1996. the DOE submitted its Compliance Certification Application (CCA) to the EPA to demonstrate compliance with the disposal standards at Subparts B and C of 40 CFR Part 191. This paper summarizes the development of the overall legal framework for radioactive waste disposal at the WIPP, the parallel development of the WIPP performance assessment (PA), and how the EPA disposal standards and implementing criteria formed the basis for the CCA WIPP PA. The CCA resulted in a certification in May 1998 by the EPA of the WIPP'S compliance with the EPA's disposal standard, thus enabling the WIPP to begin radioactive waste disposal

  15. Assessing performance in pre-season wrestling athletes using biomarkers.

    Science.gov (United States)

    Papassotiriou, Ionas; Nifli, Artemissia-Phoebe

    2018-06-15

    Although regular training introduces the desired changes in athletes' metabolism towards optimal final performance, literature is rarely focusing on the metabolic responses off-competition. Therefore, the aim of this study was to evaluate biochemical indices during typical preseason training in wrestling athletes. Twenty male freestyle and Greco-roman wrestlers (14 to 31 years) followed a typical session of the preparatory phase. Capillary blood glucose and lactate concentrations were assessed immediately before and after training. Protein, microalbumin, creatinine and their ratio were estimated the next day in the first morning urine. Pre-training lactate concentrations were lower in Greco-roman than in freestyle wrestlers (1.8 (1.4 - 2.1) vs. 2.9 (2.1 - 3.1) mmol/L). Exertion resulted in a significant increase in lactate concentrations, by 3.2 (2.6 - 4.1) mmol/L in Greco-roman wrestlers and 4.5 (3.4 - 5.3) mmol/L in freestylers. These changes were found to correlate with athlete's sport experience (r s = 0.71, P training is associated with mobilization of both lactic and alactic anaerobic energy systems. The regular comprehensive monitoring of biochemical markers would be advantageous in determining the efficiency of the preparatory phase and the long-term physiological adaptations towards the competition phase, or athlete's overtraining.

  16. Academic performance in terms of the applied assessment system

    Directory of Open Access Journals (Sweden)

    Arribas, José María

    2012-05-01

    Full Text Available This paper examines the academic performance depending on the evaluation and rating system used in the university. The sample under study consists of 30 subjects -taught by 35 professors to 2192 students from 7 different degrees at 14 universities of all Spain-. The results confirm that continuous assessment is the one that best results not only in terms of rate of return and success rate but also in terms of grades. En este trabajo se estudia el rendimiento académico en función del sistema de evaluación y calificación empleado en el ámbito universitario. La muestra objeto de estudio está formada por 30 asignaturas -impartidas por 35 profesores a 2192 alumnos de 7 titulaciones diferentes en 14 universidades de toda España-. Los resultados obtenidos confirman que la evaluación continua es la que propicia los mejores resultados no solo en cuanto a la Tasa de Rendimiento y a la Tasa de Éxito, sino también en cuanto a las calificaciones obtenidas.

  17. Performance assessment of containment filtered venting system with Venturi scrubber

    International Nuclear Information System (INIS)

    Adinarayna, K.N.V.; Ali, Seik Mansoor; Balasubramaniyan, V.

    2015-01-01

    Venting through appropriate filtration systems is now being considered as a severe accident management strategy for maintaining the containment integrity and also as a means to reduce the radiological consequences to the public and environment. The option of filtered containment venting appears to have assumed significance in the post- Fukushima accident backdrop. Back-fitting of a suitable Venturi scrubber based CFVS for the Indian BWRs (TAPS- 1 and 2) at Tarapur is now being contemplated. Several key issues need to be carefully addressed for ensuring the desired functional capability of such a system. At the outset, this paper highlights a few thermal hydraulic issues that are of interest from regulatory perspective. This is followed by a detailed description of the mathematical models developed for assessing the depressurization characteristics of CFVS, energy absorption capacity of the Scrubber Tank (ST) water inventory, iodine removal and aerosol retention capability etc. Finally, application of these models to investigate the response of CFVS under twin unit SBO conditions in TAPS-1 and 2 is presented. The studies presented here give insight into the key variables affecting the CFVS performance and would be useful to both the system designer as well as the regulator. (author)

  18. The Groundwater Performance Assessment Project Quality Assurance Plan

    International Nuclear Information System (INIS)

    Luttrell, Stuart P.

    2006-01-01

    U.S. Department of Energy (DOE) has monitored groundwater on the Hanford Site since the 1940s to help determine what chemical and radiological contaminants have made their way into the groundwater. As regulatory requirements for monitoring increased in the 1980s, there began to be some overlap between various programs. DOE established the Groundwater Performance Assessment Project (groundwater project) in 1996 to ensure protection of the public and the environment while improving the efficiency of monitoring activities. The groundwater project is designed to support all groundwater monitoring needs at the site, eliminate redundant sampling and analysis, and establish a cost-effective hierarchy for groundwater monitoring activities. This document provides the quality assurance guidelines that will be followed by the groundwater project. This QA Plan is based on the QA requirements of DOE Order 414.1C, Quality Assurance, and 10 CFR 830, Subpart A--General Provisions/Quality Assurance Requirements as delineated in Pacific Northwest National Laboratory's Standards-Based Management System. In addition, the groundwater project is subject to the Environmental Protection Agency (EPA) Requirements for Quality Assurance Project Plans (EPA/240/B-01/003, QA/R-5). The groundwater project has determined that the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD, DOE/RL-96-68) apply to portions of this project and to the subcontractors. HASQARD requirements are discussed within applicable sections of this plan

  19. The 1996 performance assessment for the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    Anderson, D.R.; Jow, H.N.; Marietta, M.G.; Chu, M.S.Y.; Shephard, L.E.; Helton, J.C.; Basabilvazo, G.

    1998-01-01

    The Waste Isolation Pilot Plant (WIPP) is under development by the US Department of Energy (DOE) for the geologic disposal of transuranic (TRU) waste that has been generated at government defense installations in the United States. The WIPP is located in an area of low population density in southeastern New Mexico. Waste disposal will take place in excavated chambers in a bedded salt formation approximately 655 m below the land surface. This presentation describes a performance assessment (PA) carried out at Sandia National Laboratories (SNL) to support the Compliance Certification Application (CCA) made by the DOE to the US Environmental Protection Agency (EPA) in October, 1996, for the certification of the WIPP for the disposal of TRU waste. Based on the CCA supported by the PA described in this presentation, the EPA has issued a preliminary decision to certify the WIPP for the disposal of TRU waste. At present (April 1998), it appears likely that the WIPP will be in operation by the end of 1998

  20. Performance assessment of U.S. residential cooking exhaust hoods.

    Science.gov (United States)

    Delp, William W; Singer, Brett C

    2012-06-05

    This study assessed the performance of seven new residential cooking exhaust hoods representing common U.S. designs. Laboratory tests were conducted to determine fan curves relating airflow to duct static pressure, sound levels, and exhaust gas capture efficiency for front and back cooktop burners and the oven. Airflow rate sensitivity to duct flow resistance was higher for axial fan devices than for centrifugal fan devices. Pollutant capture efficiency (CE) ranged from 98%, varying across hoods and with airflow and burner position for each hood. CE was higher for back burners relative to front burners, presumably because most hoods covered only part of the front burners. Open hoods had higher CE than those with grease screen and metal-covered bottoms. The device with the highest CE--exceeding 80% for oven and front burners--had a large, open hood that covered most of the front burners. The airflow rate for this hood surpassed the industry-recommended level of 118 L·s(-1) (250 cfm) and produced sound levels too high for normal conversation. For hoods meeting the sound and fan efficacy criteria for Energy Star, CE was <30% for front and oven burners.