WorldWideScience

Sample records for percutaneous needle insertions

  1. An ultrasound-driven needle-insertion robot for percutaneous cholecystostomy

    International Nuclear Information System (INIS)

    Hong, J; Dohi, T; Hashizume, M; Konishi, K; Hata, N

    2004-01-01

    A real-time ultrasound-guided needle-insertion medical robot for percutaneous cholecystostomy has been developed. Image-guided interventions have become widely accepted because they are consistent with minimal invasiveness. However, organ or abnormality displacement due to involuntary patient motion may undesirably affect the intervention. The proposed instrument uses intraoperative images and modifies the needle path in real time by using a novel ultrasonic image segmentation technique. In phantom and volunteer experiments, the needle path updating time was 130 and 301 ms per cycle, respectively. In animal experiments, the needle could be placed accurately in the target

  2. Percutaneous Ureteral stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yup; Sung, Dong Wook; Choi, Woo Suk; Lee, Dong Ho; Ko, Young Tae; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1990-10-15

    Percutaneous ureteral stent insertion is a treatment of permanent or temporary urinary diversion to maintain continuity and function of the obstructed and injured ureter. We performed 31 cases of percutaneous double pig tall ureteral stent insertion in 21 patients, included 13 patients with malignant ureteral obstruction and eight patients with injured ureter as well as benign inflammatory stricture. Satisfactory resulted was obtained in all patients but one, who need percutaneous nephrostomy on week later for urinary diversion. No significant complication was encountered. The authors concluded that percutaneous ureteral stent insertion, an interventional procedure alternative to urologic retrograde method, is an effective method for urinary diversion.

  3. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  4. Novel design of honeybee-inspired needles for percutaneous procedure.

    Science.gov (United States)

    Sahlabadi, Mohammad; Hutapea, Parsaoran

    2018-04-18

    The focus of this paper is to present new designs of innovative bioinspired needles to be used during percutaneous procedures. Insect stingers have been known to easily penetrate soft tissues. Bioinspired needles mimicking the barbs in a honeybee stinger were developed for a smaller insertion force, which can provide a less invasive procedure. Decreasing the insertion force will decrease the tissue deformation, which is essential for more accurate targeting. In this study, some design parameters, in particular, barb shape and geometry (i.e. front angle, back angle, and height) were defined, and their effects on the insertion force were investigated. Three-dimensional printing technology was used to manufacture bioinspired needles. A specially-designed insertion test setup using tissue mimicking polyvinyl chloride (PVC) gels was developed to measure the insertion and extraction forces. The barb design parameters were then experimentally modified through detailed experimental procedures to further reduce the insertion force. Different scales of the barbed needles were designed and used to explore the size-scale effect on the insertion force. To further investigate the efficacy of the proposed needle design in real surgeries, preliminary ex vivo insertion tests into bovine liver tissue were performed. Our results show that the insertion force of the needles in different scales decreased by 21-35% in PVC gel insertion tests, and by 46% in bovine liver tissue insertion tests.

  5. Pancreatic cancer seeding of percutaneous needle tract

    Directory of Open Access Journals (Sweden)

    Qiao Zhou, MD

    2017-03-01

    Full Text Available A 65-year old African-American female presents with biliary ductal dilatation due to an obstructive pancreatic head mass. Percutaneous transhepatic cholangiogram performed and biliary drainage catheter placement for decompression of the biliary system. The patient had a Whipple procedure performed several months later. On follow up CT imaging, there was interval development and enlargement of a subcutaneous lesion by the right oblique muscles. Biopsy of this lesion revealed pancreatic adenocarcinoma from percutaneous seeding of the transhepatic needle tract.

  6. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.

    Science.gov (United States)

    Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D

    2001-10-01

    The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.

  7. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  8. Emergency percutaneous needle decompression for tension pneumoperitoneum

    Directory of Open Access Journals (Sweden)

    Körner Markus

    2011-05-01

    Full Text Available Abstract Background Tension pneumoperitoneum as a complication of iatrogenic bowel perforation during endoscopy is a dramatic condition in which intraperitoneal air under pressure causes hemodynamic and ventilatory compromise. Like tension pneumothorax, urgent intervention is required. Immediate surgical decompression though is not always possible due to the limitations of the preclinical management and sometimes to capacity constraints of medical staff and equipment in the clinic. Methods This is a retrospective analysis of cases of pneumoperitoneum and tension pneumoperitoneum due to iatrogenic bowel perforation. All patients admitted to our surgical department between January 2005 and October 2010 were included. Tension pneumoperitoneum was diagnosed in those patients presenting signs of hemodynamic and ventilatory compromise in addition to abdominal distension. Results Between January 2005 and October 2010 eleven patients with iatrogenic bowel perforation were admitted to our surgical department. The mean time between perforation and admission was 36 ± 14 hrs (range 30 min - 130 hrs, between ER admission and begin of the operation 3 hrs and 15 min ± 47 min (range 60 min - 9 hrs. Three out of eleven patients had clinical signs of tension pneumoperitoneum. In those patients emergency percutaneous needle decompression was performed with a 16G venous catheter. This improved significantly the patients' condition (stabilization of vital signs, reducing jugular vein congestion, bridging the time to the start of the operation. Conclusions Hemodynamical and respiratory compromise in addition to abdominal distension shortly after endoscopy are strongly suggestive of tension pneumoperitoneum due to iatrogenic bowel perforation. This is a rare but life threatening condition and it can be managed in a preclinical and clinical setting with emergency percutaneous needle decompression like tension pneumothorax. Emergency percutaneous decompression is no

  9. [Percutaneous needle aponeurotomy for Dupuytren's disease].

    Science.gov (United States)

    Spies, C K; Müller, L P; Skouras, E; Bassemir, D; Hahn, P; Unglaub, F

    2016-02-01

    Percutaneous transverse aponeurotomy of the cord by using a hypodermic needle as a scalpel blade in order to improve function of the hand. Symptomatic flexion contracture with positive table top test caused by a single, palpable cord within the palm (primarily Tubiana stages I and II). Multiple, infiltrating or broad-based cords within the palm; irritated skin conditions; exclusive digital cord localization; recurrence after aponeurectomy; previous surgical intervention at the site of interest, digital nerve lesions; lack of patient compliance. Pinpoint surface anesthesia is obtained by injecting each portal area subdermally with 0.1 ml of local anesthetic. These applications start from distally to proximally within the palm while the most distal injection site is located proximal to the distal palm crease. Then the needle tip is introduced perpendicular to the cord. Sawing movements through the cord are performed transversely. While passively extending the contracted finger, the cord is held under tension which guarantees safe cutting. Patients are encouraged to report immediate pain sensation or numbness in order to prevent injuries to neurovascular structures and active finger flexion excludes tendon lesions during the procedure. Introducing the needle tip may be performed at several sites along the cord, if necessary, from distal to proximal at least 5 mm apart with prior pinpoint surface anesthesia. Finally, cautious passive stretching may be done after each release. Bandaging allowing immediate motion; application of a hand-based extension splint-glove during the night for 3-6 months. Recurrence rate was 53% in 15 retrospectively examined patients after a mean interval of 40 months postoperatively.

  10. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  11. Percutaneous drainage of a postoperative intraspinal hematoma using a Tuohy needle

    Energy Technology Data Exchange (ETDEWEB)

    Teo, Harvey E.L. [Department of Diagnostic Radiology, KK Women' s and Children' s Hospital (Singapore); Peh, Wilfred C.G. [Department of Diagnostic Radiology, KK Women' s and Children' s Hospital (Singapore); Programme Office, Singapore Health Services, 7 Hospital Drive 02-09, 169611 (Singapore); Tan, Seang Beng [Department of Orthopaedic Surgery, Singapore General Hospital (Singapore)

    2003-10-01

    A 78-year-old man developed a large subdural hematoma extending from T12 to L3 levels following L3 laminectomy and L3-5 posterior spinal fusion. He had associated neurological signs and symptoms. MR imaging showed typical signal characteristics of a subacute intraspinal subdural hematoma. Percutaneous drainage was successfully performed under CT guidance by inserting a Tuohy needle through the L3 laminectomy defect. The catheter packaged with the Tuohy needle was inserted cranially into the hematoma and 30 ml of blood was aspirated. Follow-up MR imaging confirmed resolution of the hematoma and the patient made a rapid recovery. (orig.)

  12. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  13. Effects of percutaneous needle liver biopsy on dairy cow behaviour

    DEFF Research Database (Denmark)

    Mølgaard, Lene; Damgaard, Birthe Marie; Bjerre-Harpøth, Vibeke

    2012-01-01

    In cattle, percutaneous needle liver biopsy is used for scientific examination of liver metabolism. The impact of the biopsy procedure is, however, poorly investigated. Our aim was to examine the behaviour of dairy cows during and after liver biopsy. Data were collected from 18 dry cows....... Percutaneous needle liver biopsies (after administration of local anaesthesia (2% Procaine)) and blood samples were taken during restraining. During the control treatment, animals were restrained and blood sampled. During the biopsy procedure, cows showed increased restlessness (P = 0.008), frequency of head...... behavioural changes for up to 19 h – and particularly for behaviour previously associated with pain. Even though the exact welfare impact of percutaneous needle liver biopsies in cows is not known, and the magnitude of the behavioural changes was limited, pain always has negative effects on animal welfare...

  14. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  15. Observations on rotating needle insertions using a brachytherapy robot

    International Nuclear Information System (INIS)

    Meltsner, M A; Ferrier, N J; Thomadsen, B R

    2007-01-01

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy

  16. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    OpenAIRE

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI ...

  17. CUDA accelerated simulation of needle insertions in deformable tissue

    International Nuclear Information System (INIS)

    Patriciu, Alexandru

    2012-01-01

    This paper presents a stiff needle-deformable tissue interaction model. The model uses a mesh-less discretization of continuum; avoiding thus the expensive remeshing required by the finite element models. The proposed model can accommodate both linear and nonlinear material characteristics. The needle-deformable tissue interaction is modeled through fundamental boundaries. The forces applied by the needle on the tissue are divided in tangent forces and constraint forces. The constraint forces are adaptively computed such that the material is properly constrained by the needle. The implementation is accelerated using NVidia CUDA. We present detailed analysis of the execution timing in both serial and parallel case. The proposed needle insertion model was integrated in a custom software that loads DICOM images, generate the deformable model, and can simulate different insertion strategies.

  18. Percutaneous core needle biopsies: The yield in spinal tuberculosis

    African Journals Online (AJOL)

    2014-01-29

    Jan 29, 2014 ... abscess formation, which was epidural in 8 and prevertebral in 13. One patient ... To (i) assess the yield of percutaneous needle biopsies; (ii) identify factors that may lead to a negative result; and (iii) determine .... ultimately detected, not testing for drug susceptibility risks a delay of .... Int J Tuberc Lung Dis.

  19. Does a paresthesia during spinal needle insertion indicate intrathecal needle placement?

    Science.gov (United States)

    Pong, Ryan P; Gmelch, Benjamin S; Bernards, Christopher M

    2009-01-01

    Paresthesias are relatively common during spinal needle insertion, however, the clinical significance of the paresthesia is unknown. A paresthesia may result from needle-to-nerve contact with a spinal nerve in the epidural space, or, with far lateral needle placement, may result from contact with a spinal nerve within the intervertebral foramen. However, it is also possible and perhaps more likely, that paresthesias occur when the spinal needle contacts a spinal nerve root within the subarachnoid space. This study was designed to test this latter hypothesis. Patients (n = 104) scheduled for surgery under spinal anesthesia were observed during spinal needle insertion. If a paresthesia occurred, the needle was fixed in place and the stylet removed to observe whether cerebrospinal fluid (CSF) flowed from the hub. The presence of CSF was considered proof that the needle had entered the subarachnoid space. Paresthesias occurred in 14/103 (13.6%) of patients; 1 patient experienced a paresthesia twice. All paresthesias were transient. Following a paresthesia, CSF was observed in the needle hub 86.7% (13/15) of the time. Our data suggest that the majority of transient paresthesias occur when the spinal needle enters the subarachnoid space and contacts a spinal nerve root. Therefore, when transient paresthesias occur during spinal needle placement it is appropriate to stop and assess for the presence of CSF in the needle hub, rather than withdraw and redirect the spinal needle away from the side of the paresthesia as some authors have suggested.

  20. Automatic needle insertion diminishes pain during growth hormone injection

    DEFF Research Database (Denmark)

    Main, K M; Jørgensen, J T; Hertel, N T

    1995-01-01

    prototype pens for GH administration, providing either manual or automatic sc needle insertion, using a combined visual analogue/facial scale and a five-item scale in 18 children. With the automatic pen there was a significantly lower maximum pain score compared with the manual pen (median 28.5 versus 52.......0 mm) as well as a lower mean pain score (mean 13.7 versus 23.5 mm). The five-item scale revealed that automatic needle insertion was significantly less painful than manual insertion and 13 patients chose to continue treatment with the automatic pen. In conclusion, pain during GH injection can...

  1. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist

  2. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation.

    Science.gov (United States)

    Limmer, Alexandra M; Clement, Zackariah

    2017-01-01

    Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  3. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation

    Directory of Open Access Journals (Sweden)

    Alexandra M. Limmer

    2017-01-01

    Full Text Available Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient’s caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  4. MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images

    Science.gov (United States)

    Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.

    2018-04-01

    In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.

  5. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  6. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  7. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  8. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation

    OpenAIRE

    Limmer, Alexandra M.; Clement, Zackariah

    2017-01-01

    Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was ...

  9. Development of Needle Insertion Manipulator for Central Venous Catheterization

    Science.gov (United States)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  10. Skin Blood Perfusion and Cellular Response to Insertion of Insulin Pen Needles With Different Diameters

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente Merete; Bo Jensen, Casper

    2014-01-01

    skin blood perfusion response around needle insertion sites. Three common sized pen needles of 28G, 30G, and 32G as well as hooked 32G needles, were inserted into the neck skin of pigs and then removed. Laser Speckle Contrast Analysis was used to measure skin blood perfusion for 20 minutes after...... blood perfusion recording and grouped according to needle type, skin blood perfusion response relates to needle diameter. The response was significantly higher after insertions with 28G and hooked 32G needles than with 30G (P ..., but there was a trend of an increased response with increasing needle diameter. Skin blood perfusion response to pen needle insertions rank according to needle diameter, and the tissue response caused by hooked 32G needles corresponds to that of 28G needles. The relation between needle diameter and trauma when...

  11. Effects of Rotational Motion in Robotic Needle Insertion

    Science.gov (United States)

    Ramezanpour, H.; Yousefi, H.; Rezaei, M.; Rostami, M.

    2015-01-01

    Background Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations. Objective In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploited as a tissue sample under standard compression test with Zwick/Roell device employing 1-D axial load-cell. Methods Effects of rotational motion were studied by running needle insertion experiments in 5, 50 and 200 mm/min in two types of with or without rotational velocity of 50, 150 and 300 rpm. On further steps with deeper penetrations, friction force of the insertion procedure in needle shaft was acquired by a definite thickness of the tissue. Results Designed mechanism of fixture for providing different frequencies of rotational motion is available in this work. Results for comparison of different force graphs were also provided. Conclusion Derived force-displacement graphs showed a significant difference between two procedures; however, tissue bleeding and disorganized micro-structure would be among unavoidable results. PMID:26688800

  12. Dynamics of translational friction in needle-tissue interaction during needle insertion.

    Science.gov (United States)

    Asadian, Ali; Patel, Rajni V; Kermani, Mehrdad R

    2014-01-01

    In this study, a distributed approach to account for dynamic friction during needle insertion in soft tissue is presented. As is well known, friction is a complex nonlinear phenomenon. It appears that classical or static models are unable to capture some of the observations made in systems subjected to significant frictional effects. In needle insertion, translational friction would be a matter of importance when the needle is very flexible, or a stop-and-rotate motion profile at low insertion velocities is implemented, and thus, the system is repeatedly transitioned from a pre-sliding to a sliding mode and vice versa. In order to characterize friction components, a distributed version of the LuGre model in the state-space representation is adopted. This method also facilitates estimating cutting force in an intra-operative manner. To evaluate the performance of the proposed family of friction models, experiments were conducted on homogeneous artificial phantoms and animal tissue. The results illustrate that our approach enables us to represent the main features of friction which is a major force component in needle-tissue interaction during needle-based interventions.

  13. Smart surgical needle actuated by shape memory alloys for percutaneous procedures

    Science.gov (United States)

    Konh, Bardia

    Background: Majority of cancer interventions today are performed percutaneously using needle-based procedures, i.e. through the skin and soft tissue. Insufficient accuracy using conventional surgical needles motivated researchers to provide actuation forces to the needle's body for compensating the possible errors of surgeons/physicians. Therefore, active needles were proposed recently where actuation forces provided by shape memory alloys (SMAs) are utilized to assist the maneuverability and accuracy of surgical needles. This work also aims to introduce a novel needle insertion simulation to predict the deflection of a bevel tip needle inside the tissue. Methods: In this work first, the actuation capability of a single SMA wire was studied. The complex response of SMAs was investigated via a MATLAB implementation of the Brinson model and verified via experimental tests. The material characteristics of SMAs were simulated by defining multilinear elastic isothermal stress-strain curves. Rigorous experiments with SMA wires were performed to determine the material properties as well as to show the capability of the code to predict a stabilized SMA transformation behavior with sufficient accuracy. The isothermal stress-strain curves of SMAs were simulated and defined as a material model for the Finite Element Analysis of the active needle. In the second part of this work, a three-dimensional finite element (FE) model of the active steerable needle was developed to demonstrate the feasibility of using SMA wires as actuators to bend the surgical needle. In the FE model, birth and death method of defining boundary conditions, available in ANSYS, was used to achieve the pre-strain condition on SMA wire prior to actuation. This numerical model was validated with needle deflection experiments with developed prototypes of the active needle. The third part of this work describes the design optimization of the active using genetic algorithm aiming for its maximum flexibility

  14. Complications of Percutaneous Nephrostomy, Percutaneous Insertion of Ureteral Endoprosthesis, and Replacement Procedures

    International Nuclear Information System (INIS)

    Kaskarelis, Ioannis S.; Papadaki, Marina G.; Malliaraki, Niki E.; Robotis, Epaminondas D.; Malagari, Katerina S.; Piperopoulos, Ploutarchos N.

    2001-01-01

    Purpose: The aim of the present study was to record and identify the frequency of complications following percutaneous nephrostomy, replacement of nephrostomy drains and percutaneous insertion of ureteral endoprostheses.Methods: During a 10-year period 341 patients were referred to our department with indications for percutaneous nephrostomy and/or percutaneous insertion of a ureteral endoprosthesis, and a total of 1036 interventional procedures were performed (nephrostomy, catheter change, stenting).Results: There were three major complications (0.29%): two patients died during the first 30 days after the procedure, due to aggravation of their condition caused by the procedure, and one patient had retroperitoneal bleeding requiring surgery. There were 76 complications of intermediate severity (7.33%): catheter or stent displacement (n = 37, 3.57%) catheter occlusion (n = 18, 1.73%), hematuria (n = 12, 1.16%), and urinary tract infection (n = 9, 0.87%). The 55 minor complications (5.3%) comprised inflammation of the skin at the site of insertion of the percutaneous catheter.Conclusion: The small number of complications observed during acts of interventional uroradiology prove transcutaneous manipulations to be safe medical procedures

  15. Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images

    NARCIS (Netherlands)

    Shahriari, Navid; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak

    2015-01-01

    Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection reduces

  16. Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images

    NARCIS (Netherlands)

    Shahriari, Navid; Hekman, Edsko E.G.; Oudkerk, Matthijs; Misra, Sarthak

    2015-01-01

    Purpose Percutaneous needle insertion procedures are commonly used for diagnostic and therapeutic purposes. Although current technology allows accurate localization of lesions, they cannot yet be precisely targeted. Lung cancer is the most common cause of cancer-related death, and early detection

  17. Percutaneous needle-biopsy of the adrenal glands

    International Nuclear Information System (INIS)

    Wernecke, K.; Galanski, M.

    1986-01-01

    This account of techniques, range of indications and results of percutaneous adrenal biopsy refers to communications in the literature and to the authors' own experience. Lateral, transhepatic aspiration of adrenal material guided by sonographic control is more easy in the right adrenal gland. Punctation of the left adrenal gland ought to be done from the back and guided by computerized tomography, also in order to leave spleen, kidney, pancreas and stomach as unaffected as possible. The most frequent problem indicating adrenal biopsy still is differentiation between metastases or encretorily non-active adenomas in tumor patients. Experienced examiners will achieve an 80 to 90% sensitivity of adrenal biopsy. Clinically established, suspected phaeochromocytoma is an absolute contra-indication to fine-needle biopsy. (orig./MG) [de

  18. Investigating the Effects of Three Needling Parameters (Manipulation, Retention Time, and Insertion Site) on Needling Sensation and Pain Profiles: A Study of Eight Deep Needling Interventions

    Science.gov (United States)

    Loyeung, Bertrand Y. K.; Cobbin, Deirdre M.

    2013-01-01

    Introduction. In traditional Chinese acupuncture, needle sensation (deqi) is purported to contribute to a therapeutic outcome. While researchers have attempted to define deqi qualitatively, few have examined the effects of needling parameters on its intensity. Methods. 24 healthy subjects completed eight interventions scheduled at least one week apart, which involved manual acupuncture to LI4 or a designated nonacupoint (NAP) on the hand, with real or simulated manipulation each three minutes and needle retentions of one or 21 minutes. Intensities of needling sensation and pain were reported every three minutes and sensation qualities were reported post-intervention. Results. Immediately after needle insertion, similar levels of mean needle sensation and of pain were reported independent of intervention. At subsequent measurement times, only two interventions (one at LI4 and one at NAP) maintained statistically significantly elevated needle sensation and pain scores and reported higher numbers of needle sensation descriptors. For both, the needle was retained for 21 minutes and manipulated every three minutes. Neither intervention differed significantly in terms of levels of pain, and needle sensation or numbers and qualities of needle sensation described. Conclusion. In this group of healthy subjects, the initial needling for all eight interventions elicited similar levels of needle sensation and pain. These levels were only maintained if there was ongoing of needle manipulation and retention of the needle. By contrast, the strength of needle sensation or pain experienced was independent of insertion site. PMID:24159337

  19. Tumour seeding following percutaneous needle biopsy: The real story

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, E.G. [Department of Radiology, Western Infirmary, Glasgow (United Kingdom); Baxter, G., E-mail: grant.baxter@ggc.scot.nhs.uk [Department of Radiology, Western Infirmary, Glasgow (United Kingdom)

    2011-11-15

    The demand for percutaneous needle biopsy is greater than ever before and with the majority of procedures requiring imaging guidance, radiologists have an increasingly important role in the diagnostic work-up of patients with suspected malignancy. All invasive procedures incur potential risks; therefore, clinicians should be aware of the most frequently encountered complications and have a realistic idea of their likelihood. Tumour seeding, whereby malignant cells are deposited along the tract of a biopsy needle, can have disastrous consequences particularly in patients who are organ transplant candidates or in those who would otherwise expect good long-term survival. Fortunately, tumour seeding is a rare occurrence, yet the issue invariably receives a high profile and is often regarded as a major contraindication to certain biopsy procedures. Although its existence is in no doubt, realistic insight into its likelihood across the spectrum of biopsy procedures and multiple anatomical sites is required to permit accurate patient counselling and risk stratification. This review provides a comprehensive overview of tumour seeding and examines the likelihood of this much feared complication across the range of commonly performed diagnostic biopsy procedures. Conclusions have been derived from an extensive analysis of the published literature, and a number of key recommendations should assist practitioners in their everyday practice.

  20. Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J. [Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, State College, Pennsylvania 16802 (United States); Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 and Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2012-04-15

    Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

  1. [Acupuncture therapy for regaining consciousness in terms of acupoint location, needle insertion and needle manipulation].

    Science.gov (United States)

    Meng, Xianggang; Gu, Wenlong; Ma, Fen; Du, Yuzheng; Zhao, Qi

    2015-03-01

    Acupuncture therapy for regaining consciousness activates soreness, numbness, distention, heaviness, radiating and moving, electric shock and ant climbing sensations at the specific acupoints in the stroke patients. Radiating and moving sensations are the summary of needling sensations such as soreness, numbness and twitching presenting during lifting and thrusting manipulation. These sensations are the essential factors of the therapeutic effect of regaining consciousness. Radiating sensation refers to the conduction along meridians and radiation of soreness and numbness. Moving sensation refers to the local muscular twitching at acupoints and the involuntary movement of limbs, joints and the distal. Acupuncture at the specific acupoints achieves radiating and moving sensations for promoting the circulation in meridians, regulating qi and mind and balancing yin and yang in stroke patients. This therapy was introduced in the paper in view of acupoint location, needle insertion and manipulation.

  2. Precision grid and hand motion for accurate needle insertion in brachytherapy

    International Nuclear Information System (INIS)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J.

    2011-01-01

    Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2 3 factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

  3. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  4. Quantification of Tissue Trauma following Insulin Pen Needle Insertions in Skin

    DEFF Research Database (Denmark)

    Jensen, Casper Bo; Larsen, Rasmus; Vestergaard, Jacob Schack

    Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop a computa......Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop...... a computational method to quantify tissue trauma based on skin bleeding and immune response. Method: Two common sized pen needles of 28G (0.36mm) and 32G (0.23mm) were inserted into skin of sedated LYD pigs prior to termination. Four pigs were included and a total of 32 randomized needle insertions were conducted...... diameter. Conclusion: A computational and quantitative method has been developed to assess tissue trauma following insulin pen needle insertions. Application of the method is tested by conduction of a needle diameter study. The obtained quantitative measures of tissue trauma correlate positively to needle...

  5. SU-D-213AB-06: Surface Texture and Insertion Speed Effect on Needle Friction.

    Science.gov (United States)

    Abdullah, A; Golecki, C; Barnett, A; Moore, J

    2012-06-01

    High frictional forces between the needle surface and tissue cause tissue deflection which hinders accurate needle placement for procedures such as brachytherapy and needle biopsy. Accurate needle placement isimportant to maximize procedure efficacy. This work investigates how needle surface roughness and insertion speed affect the frictional forcebetween a needle and tissue. A friction experiment was conducted to measure the force of friction between bovine liver and three 11 gauge needles having Ra surface roughness of 3.43, 1.33, and 0.2 μm. Each of the three needles were mounted on a linear slide and were advanced and retracted through bovine liver at speeds of 50, 100, 150, and 200 mm/s for a total of 12 trials. In each trial the needle was advanced and retracted in 10 cycles producing a steady state insertion force and a steady state retraction force for each cycle. A force sensor connecting the needle to the linear slide recorded the resistance force of the needle sliding through the liver. The liver was mounted in a box with a pneumatic cylinder which compressed the liver sample by 11.65 kPa. The roughest needle (Ra = 3.43 μm) on average produced 68, 73, 74, and 73% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200mm/s, respectively. The second roughest needle (Ra = 1.33 μm) on average produced 25, 45, 60 and 64% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200 mm/s, respectively. Rougher needle surface texture and higher insertion speed reduced frictional forces between the tissue and the needle. Future studies will examine how frictional forces can be modeled and predicted given surface texture and insertion speed. © 2012 American Association of Physicists in Medicine.

  6. Self-insertion of needle as urethral foreign body after sexual gratification: An unusual case report

    Directory of Open Access Journals (Sweden)

    Metin Tahaoglu

    2014-08-01

    Full Text Available Self-inserted foreign bodies in the urethra are rare among children. We describe here a 13-year-old boy who had self-inserted a needle into his urethra. Selfinsertion of the needle wrapped with cotton into the urethra for cleaning after masturbation by patient was applied. A foreign body in the urethra was removed by cystoscopy.

  7. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  8. A new robotic needle insertion method to minimise attendant prostate motion

    International Nuclear Information System (INIS)

    Lagerburg, Vera; Moerland, Marinus A.; Vulpen, Marco van; Lagendijk, Jan J.W.

    2006-01-01

    Background and purpose: The purpose of this study is to investigate the efficacy of a new needle insertion method (tapping instead of pushing) in reducing attendant tissue motion. This can be useful in applications where tissue motion due to needle insertion is problematic such as e.g. MRI-guided prostate brachytherapy and breast biopsies. In this study we will focus on prostate motion due to needle insertion. Material and methods: Prostate motion due to needle insertion was measured in 30 patients, who were transperineally implanted with fiducial gold markers for position verification in prostate intensity modulated radiotherapy. In total 32 needles were manually pushed into the prostate and 29 were tapped with a prototype robotic system. The prostate motion in the cranio-caudal direction was measured on the video record of the ultrasound images. Differences in prostate motion between the two needle insertion methods were analysed making use of SPSS. Results: The mean prostate motion was 5.6 mm (range 0.3-21.6) when the needle was pushed and 0.9 mm (range 0-2.0) when the needle was tapped into the prostate (p < 0.001). Conclusion: Prostate motion was significantly less when the needle was tapped into the prostate compared to when the needle was pushed. This result is important for the development of a tapping, MRI-guided, prostate implant robotic system

  9. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback.

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.

  10. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2014-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446

  11. Percutaneous CT-Guided Core Needle Biopsy Versus Fine Needle Aspiration in Diagnosing Pneumonia and Mimics of Pneumonia

    International Nuclear Information System (INIS)

    Thanos, Loukas; Galani, Panagiota; Mylona, Sophia; Pomoni, Maria; Mpatakis, Nikolaos

    2004-01-01

    The purpose of this study was to determine the diagnostic value of percutaneous core needle biopsy (CNB) relative to fine needle aspiration (FNA) in patients with pneumonia and pneumonia mimics. In this prospective study we present our experience with 48 thoracic FNAs and CNBs carried out on 48 patients with pneumonia and pneumonia mimics. Samples were obtained from all patients using both CNB (with an automated 18-G core biopsy needle and a gun) and FNA (with a 22-G needle). A specific diagnosis was made in 10/48 cases (20.83%) by FNA and in 42/48 (87.5%) by CNB. The main complications encountered were pneumothorax (n = 4) and hemoptysis (n = 2), yielding a total complication rate of 12.5%. We concluded that CNB using an automated biopsy gun results in a higher diagnostic accuracy for pneumonia and pneumonia mimic biopsies than FNA. Complications should be considered and proper patient observation should follow the procedure

  12. Fatal paradoxical pulmonary air embolism complicating percutaneous computed tomography-guided needle biopsy of the lung

    International Nuclear Information System (INIS)

    Chakravarti, Rajesh; Singh, Virendra; Isaac, Rethish; John, Joseph

    2004-01-01

    A 63-year-old man with left upper zone haziness on chest X-ray and an infiltrative lesion with a pleural mass in the left upper lobe on CT scan was scheduled for CT-guided percutaneous trans-thoracic needle biopsy. During the procedure, the patient had massive haemoptysis and cardiorespiratory arrest and could not be revived. Post-mortem CT showed air in the right atrium, right ventricle, pulmonary artery and also in the left atrium and aorta. A discussion on paradoxical air embolism following percutaneous trans-thoracic needle biopsy is presented Copyright (2004) Blackwell Publishing Asia Pty Ltd

  13. Development of a virtual reality haptic Veress needle insertion simulator for surgical skills training.

    Science.gov (United States)

    Okrainec, A; Farcas, M; Henao, O; Choy, I; Green, J; Fotoohi, M; Leslie, R; Wight, D; Karam, P; Gonzalez, N; Apkarian, J

    2009-01-01

    The Veress needle is the most commonly used technique for creating the pneumoperitoneum at the start of a laparoscopic surgical procedure. Inserting the Veress needle correctly is crucial since errors can cause significant harm to patients. Unfortunately, this technique can be difficult to teach since surgeons rely heavily on tactile feedback while advancing the needle through the various layers of the abdominal wall. This critical step in laparoscopy, therefore, can be challenging for novice trainees to learn without adequate opportunities to practice in a safe environment with no risk of injury to patients. To address this issue, we have successfully developed a prototype of a virtual reality haptic needle insertion simulator using the tactile feedback of 22 surgeons to set realistic haptic parameters. A survey of these surgeons concluded that our device appeared and felt realistic, and could potentially be a useful tool for teaching the proper technique of Veress needle insertion.

  14. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Science.gov (United States)

    Chesnel, Camille; Genêt, François; Almangour, Waleed; Denormandie, Philippe; Parratte, Bernard; Schnitzler, Alexis

    2015-01-01

    Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning) is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia. To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers. Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons) carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred. Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%): 4 (1%) in tendons or muscles, 3 (0.7%) in nerves and 1 (0.2%) in a vessel. This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  15. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  16. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  17. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  18. Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.

    Science.gov (United States)

    Tudor, G R; Rodgers, P M; West, K P

    1999-08-01

    Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.

  19. A variable stiffness mechanism for steerable percutaneous instruments: integration in a needle.

    Science.gov (United States)

    De Falco, Iris; Culmone, Costanza; Menciassi, Arianna; Dankelman, Jenny; van den Dobbelsteen, John J

    2018-06-04

    Needles are advanced tools commonly used in minimally invasive medical procedures. The accurate manoeuvrability of flexible needles through soft tissues is strongly determined by variations in tissue stiffness, which affects the needle-tissue interaction and thus causes needle deflection. This work presents a variable stiffness mechanism for percutaneous needles capable of compensating for variations in tissue stiffness and undesirable trajectory changes. It is composed of compliant segments and rigid plates alternately connected in series and longitudinally crossed by four cables. The tensioning of the cables allows the omnidirectional steering of the tip and the stiffness tuning of the needle. The mechanism was tested separately under different working conditions, demonstrating a capability to exert up to 3.6 N. Afterwards, the mechanism was integrated into a needle, and the overall device was tested in gelatine phantoms simulating the stiffness of biological tissues. The needle demonstrated the capability to vary deflection (from 11.6 to 4.4 mm) and adapt to the inhomogeneity of the phantoms (from 21 to 80 kPa) depending on the activation of the variable stiffness mechanism. Graphical abstract ᅟ.

  20. Is percutaneous fine-needle biopsy a hazard? An update

    International Nuclear Information System (INIS)

    Smith, E.H.

    1987-01-01

    Fine-needle biopsy (FNB) has become a commonplace diagnostic procedure in most radiology departments with the assumption that risks are nonexistent. Animal experiments conclusively indicate the leakage of tumor cells after biopsy, but clinical evidence appears to point to a paucity of complications. In a prior review of the literature, two needle tract seedings (NTS) and two fatalities after FNB were discovered. A questionnaire at that time uncovered three more cases of NTS and four deaths. An updated literature search and questionnaire showed an additional 14 cases of NTS and nine deaths. An analysis of the date are reported

  1. The clinical application of percutaneous large core needle biopsy on large breast mass

    International Nuclear Information System (INIS)

    Peng Songhong; Ma Jie; Wang Guohong; Sun Guoping; Fu Jianmin; Zhou Dongxian

    2005-01-01

    Objective: An evaluation of the clinical application of percutaneous large core needle biopsy on large breast mass. Methods: Mammography and percutaneous large core needle biopsy were performed in 31 cases of large breast mass. Results: Apart from 5 cases showing characteristic calcification of malignancy, the rest cases were lack of diagnostic manifestation. Needle biopsy and pathological examination identified breast canner in 11 cases, suppurative mastitis in 9 case, fibrocystic mammary disorder in 7 cases, tuberculosis in 1 case, and fibroadenoma in 3 cases. Fibrocystic mammary disease was initially identified by biopsy in a case, while the following pathological diagnosis was fibrocystic mammary disorder with cancinoma in sim. Specificity rate of' biopsy was 96.8% and no false positive was observed. Vagotonia occurred in one case during the biopsy and hematoma in another. Conclusion: Percutaneous large core needle biopsy is a less invasive, simple, safe and reliable methods in the diagnosis of the large breast mass. And it may be recommended as a complementary procedure for routine imaging modality or surgical resection. (authors)

  2. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Directory of Open Access Journals (Sweden)

    Camille Chesnel

    Full Text Available Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia.To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers.Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred.Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%: 4 (1% in tendons or muscles, 3 (0.7% in nerves and 1 (0.2% in a vessel.This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  3. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    Science.gov (United States)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  4. Clinical application of percutaneous needling lung abscess drairnage under CT guidance

    International Nuclear Information System (INIS)

    Hu Xiaokun; Wang Mingyou; Li Chenjun; Lv Dongfang; Li Xiaodong; Yu Zhaocun

    2004-01-01

    Objective: To discuss the clinical application of drainage for lung abscess by needle puncture under CT guidance. Methods: 18 cases of lung abscess were drainaged by needle puncture under CT guidance, including direct aspiration by puncture needle 1-3 times (n=8) and retaining drainage tube continuously (n=10). Results: 17 cases with this procedure were succeeded possessing success rate of 94.7%(17/18). The patients were followed up for 11-35 days with symptom relieving better obviously and the focus shrinkage or disappeared (n=16), the curative rate reached 88.9%(16/18). The main complication was pneumothorax with capacities of 30%(n=1). Conclusions: The curative course of lung abscess can be shortened greatly by percutaneous needling drainage under CT guidance with mild trauma. The procedure is simple with high successful rate and less complication. (authors)

  5. Peritonitis following percutaneous gastrostomy tube insertions in children

    International Nuclear Information System (INIS)

    Dookhoo, Leema; Mahant, Sanjay; Parra, Dimitri A.; John, Philip R.; Amaral, Joao G.; Connolly, Bairbre L.

    2016-01-01

    Percutaneous retrograde gastrostomy has a high success rate, low morbidity, and can be performed under different levels of sedation or local anesthesia in children. Despite its favourable safety profile, major complications can occur. Few studies have examined peritonitis following percutaneous retrograde gastrostomy in children. To identify potential risk factors and variables influencing the development and early diagnosis of peritonitis following percutaneous retrograde gastrostomy. We conducted a retrospective case-control study of children who developed peritonitis within 7 days of percutaneous retrograde gastrostomy between 2003 and 2012. From the 1,504 patients who underwent percutaneous retrograde gastrostomy, patients who developed peritonitis (group 1) were matched by closest date of procedure to those without peritonitis (group 2). Peritonitis was defined according to recognized clinical criteria. Demographic, clinical, procedural, management and outcomes data were collected. Thirty-eight of 1,504 children (2.5%; 95% confidence interval, 1.8-3.5) who underwent percutaneous retrograde gastrostomy developed peritonitis ≤7 days post procedure (group 1). Fever (89%), irritability (63%) and abdominal pain (55%) occurred on presentation of peritonitis. Group 1 patients were all treated with antibiotics; 41% underwent additional interventions: tube readjustments (8%), aspiration of pneumoperitoneum (23%), laparotomy (10%) and intensive care unit admission (10%). In group 1, enteral feeds started on average 3 days later and patients were discharged 5 days later than patients in group 2. There were two deaths not directly related to peritonitis. Neither age, gender, weight, underlying diagnoses nor operator was identified as a risk factor. Peritonitis following percutaneous retrograde gastrostomy in children occurs in approximately 2.5% of cases. No risk factors for its development were identified. Medical management is usually sufficient for a good outcome

  6. Peritonitis following percutaneous gastrostomy tube insertions in children.

    Science.gov (United States)

    Dookhoo, Leema; Mahant, Sanjay; Parra, Dimitri A; John, Philip R; Amaral, Joao G; Connolly, Bairbre L

    2016-09-01

    Percutaneous retrograde gastrostomy has a high success rate, low morbidity, and can be performed under different levels of sedation or local anesthesia in children. Despite its favourable safety profile, major complications can occur. Few studies have examined peritonitis following percutaneous retrograde gastrostomy in children. To identify potential risk factors and variables influencing the development and early diagnosis of peritonitis following percutaneous retrograde gastrostomy. We conducted a retrospective case-control study of children who developed peritonitis within 7 days of percutaneous retrograde gastrostomy between 2003 and 2012. From the 1,504 patients who underwent percutaneous retrograde gastrostomy, patients who developed peritonitis (group 1) were matched by closest date of procedure to those without peritonitis (group 2). Peritonitis was defined according to recognized clinical criteria. Demographic, clinical, procedural, management and outcomes data were collected. Thirty-eight of 1,504 children (2.5%; 95% confidence interval, 1.8-3.5) who underwent percutaneous retrograde gastrostomy developed peritonitis ≤7 days post procedure (group 1). Fever (89%), irritability (63%) and abdominal pain (55%) occurred on presentation of peritonitis. Group 1 patients were all treated with antibiotics; 41% underwent additional interventions: tube readjustments (8%), aspiration of pneumoperitoneum (23%), laparotomy (10%) and intensive care unit admission (10%). In group 1, enteral feeds started on average 3 days later and patients were discharged 5 days later than patients in group 2. There were two deaths not directly related to peritonitis. Neither age, gender, weight, underlying diagnoses nor operator was identified as a risk factor. Peritonitis following percutaneous retrograde gastrostomy in children occurs in approximately 2.5% of cases. No risk factors for its development were identified. Medical management is usually sufficient for a good outcome

  7. Peritonitis following percutaneous gastrostomy tube insertions in children

    Energy Technology Data Exchange (ETDEWEB)

    Dookhoo, Leema [The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada); University of Toronto, Faculty of Medicine, Toronto, ON (Canada); Mahant, Sanjay [The Hospital for Sick Children, Department of Pediatrics, Toronto, ON (Canada); Parra, Dimitri A.; John, Philip R.; Amaral, Joao G.; Connolly, Bairbre L. [The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada)

    2016-09-15

    Percutaneous retrograde gastrostomy has a high success rate, low morbidity, and can be performed under different levels of sedation or local anesthesia in children. Despite its favourable safety profile, major complications can occur. Few studies have examined peritonitis following percutaneous retrograde gastrostomy in children. To identify potential risk factors and variables influencing the development and early diagnosis of peritonitis following percutaneous retrograde gastrostomy. We conducted a retrospective case-control study of children who developed peritonitis within 7 days of percutaneous retrograde gastrostomy between 2003 and 2012. From the 1,504 patients who underwent percutaneous retrograde gastrostomy, patients who developed peritonitis (group 1) were matched by closest date of procedure to those without peritonitis (group 2). Peritonitis was defined according to recognized clinical criteria. Demographic, clinical, procedural, management and outcomes data were collected. Thirty-eight of 1,504 children (2.5%; 95% confidence interval, 1.8-3.5) who underwent percutaneous retrograde gastrostomy developed peritonitis ≤7 days post procedure (group 1). Fever (89%), irritability (63%) and abdominal pain (55%) occurred on presentation of peritonitis. Group 1 patients were all treated with antibiotics; 41% underwent additional interventions: tube readjustments (8%), aspiration of pneumoperitoneum (23%), laparotomy (10%) and intensive care unit admission (10%). In group 1, enteral feeds started on average 3 days later and patients were discharged 5 days later than patients in group 2. There were two deaths not directly related to peritonitis. Neither age, gender, weight, underlying diagnoses nor operator was identified as a risk factor. Peritonitis following percutaneous retrograde gastrostomy in children occurs in approximately 2.5% of cases. No risk factors for its development were identified. Medical management is usually sufficient for a good outcome

  8. Performance of a New Blunt-Tip Coaxial Needle for Percutaneous Biopsy and Drainage of "Hard-To-Reach" Targets.

    Science.gov (United States)

    Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Caudrelier, Jean; Bauones, Salem; Tsoumakidou, Georgia; Koch, Guillaume; Gangi, Afshin

    2017-09-01

    To present a new blunt-tip coaxial needle (SoftGuard) applied to access "hard-to-reach" targets undergoing percutaneous image-guided biopsy or drainage. All consecutive patients presenting between August and December 2016 with "hard-to-reach" (blunt-tip needle is a safe and effective tool when applied as a coaxial working cannula for percutaneous biopsy or drainage of "hard-to-reach" targets.

  9. Safety and Effectiveness of Percutaneously Inserted Peritoneal Ports Compared to Surgically Inserted Ports in a Retrospective Study of 87 Patients with Ovarian Carcinoma over a 10-Year Period

    International Nuclear Information System (INIS)

    Woodley-Cook, Joel; Tarulli, Emidio; Tan, Kong T.; Rajan, Dheeraj K.; Simons, Martin E.

    2016-01-01

    PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted ports were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.

  10. Safety and Effectiveness of Percutaneously Inserted Peritoneal Ports Compared to Surgically Inserted Ports in a Retrospective Study of 87 Patients with Ovarian Carcinoma over a 10-Year Period

    Energy Technology Data Exchange (ETDEWEB)

    Woodley-Cook, Joel, E-mail: jwoodleycook@gmail.com [The Scarborough Hospital, Vascular and Interventional Radiology, Department of Diagnostic Imaging (Canada); Tarulli, Emidio; Tan, Kong T.; Rajan, Dheeraj K.; Simons, Martin E. [University of Toronto, Vascular and Interventional Radiology, Department of Medical Imaging, University Health Network (Canada)

    2016-11-15

    PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted ports were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.

  11. Diagnostic Accuracy of MRI-guided Percutaneous Transthoracic Needle Biopsy of Solitary Pulmonary Nodules

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shangang, E-mail: 1198685580@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Li, Chengli, E-mail: chenglilichina@yeah.net [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Yu, Xuejuan, E-mail: yuxuejuan2011@126.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China); Liu, Ming, E-mail: mingliuyxs@163.com [Shandong University, Department of Interventional MRI, Shandong Medical Imaging Research Institute (China); Fan, Tingyong, E-mail: FTY681105@sohu.com; Chen, Dong, E-mail: 857984870@qq.com; Zhang, Pinliang, E-mail: zhangpinliang@163.com; Ren, Ruimei, E-mail: liusg708@qq.com [University of Jinan-Shandong Academy of Medical Science, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, School of Medicine and Life Sciences (China)

    2015-04-15

    ObjectiveThe purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs).MethodsRetrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The final diagnosis was established by surgical pathology of the nodule or clinical and imaging follow-up. Pneumothorax rate and diagnostic accuracy were compared between two groups according to nodule diameter (≤2 vs. >2 cm) using χ{sup 2} chest and Fisher’s exact test, respectively.ResultsThe success rate of single puncture was 95.6 %. Twelve (17.4 %) patients had pneumothorax, with 1 (1.4 %) requiring chest tube insertion. Mild hemoptysis occurred in 7 (7.2 %) patients. All of the sample material was sufficient for histological diagnostic evaluation. Pathological analysis of biopsy specimens showed 46 malignant, 22 benign, and 1 nondiagnostic nodule. The final diagnoses were 49 malignant nodules and 20 benign nodules basing on postoperative histopathology and clinical follow-up data. One nondiagnostic sample was excluded from calculating diagnostic performance. A sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in diagnosing SPNs were 95.8, 100, 97.0, 100, and 90.9 %, respectively. Pneumothorax rate, diagnostic sensitivity, and accuracy were not significantly different between the two groups (P > 0.05).ConclusionsMRI-guided PTNB is safe, feasible, and high accurate diagnostic technique for pathologic diagnosis of pulmonary nodules.

  12. Computed tomography-guided percutaneous core needle biopsy of deep seated bone lesions in two dogs

    International Nuclear Information System (INIS)

    Mori, T.; Sakaida, M.; Yamada, M.; Akiyama, H.; Takai, Y.; Sakai, H.; Maruo, K.

    2006-01-01

    Computed Tomography (CT)-guided percutaneous core needle biopsies were undertaken for the diagnosis of osteosarcoma in the pelvis (case 1) and myeloma (case 2) in the seventh lumber vertebra which were difficult to targeted by palpation, ultrasound or fluoroscopy. In both cases, enough tissue for pathological diagnosis were obtained without any complication. CT-guided biopsy was thought to be a safe, easy and effective technique for the evaluation of the deep seated bone lesion

  13. Sonographic Finding of Scrotal Cystic Lymphangioma with Hemorrhage Caused by Percutaneous Needle Aspiration: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Woon; Cho, Jae Ho [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2011-03-15

    Lymphangioma is a hamartoma, which is a benign tumor caused by congenital malformation of the lymphatic system. These tumors usually occur in the neck and axilla, and occasionally in the mediastinum, mesenterium, retroperitoneum and thigh, The scrotum and perineum are the least frequent sites. We report here on an uncommon case of cystic lymphangioma that presented as focal hemorrhage caused by percutaneous needle aspiration, and we briefly review the radiologic finding and the relevant literature

  14. Inserting needles into the body: a meta-analysis of brain activity associated with acupuncture needle stimulation.

    Science.gov (United States)

    Chae, Younbyoung; Chang, Dong-Seon; Lee, Soon-Ho; Jung, Won-Mo; Lee, In-Seon; Jackson, Stephen; Kong, Jian; Lee, Hyangsook; Park, Hi-Joon; Lee, Hyejung; Wallraven, Christian

    2013-03-01

    Acupuncture is a therapeutic treatment that is defined as the insertion of needles into the body at specific points (ie, acupoints). Advances in functional neuroimaging have made it possible to study brain responses to acupuncture; however, previous studies have mainly concentrated on acupoint specificity. We wanted to focus on the functional brain responses that occur because of needle insertion into the body. An activation likelihood estimation meta-analysis was carried out to investigate common characteristics of brain responses to acupuncture needle stimulation compared to tactile stimulation. A total of 28 functional magnetic resonance imaging studies, which consisted of 51 acupuncture and 10 tactile stimulation experiments, were selected for the meta-analysis. Following acupuncture needle stimulation, activation in the sensorimotor cortical network, including the insula, thalamus, anterior cingulate cortex, and primary and secondary somatosensory cortices, and deactivation in the limbic-paralimbic neocortical network, including the medial prefrontal cortex, caudate, amygdala, posterior cingulate cortex, and parahippocampus, were detected and assessed. Following control tactile stimulation, weaker patterns of brain responses were detected in areas similar to those stated above. The activation and deactivation patterns following acupuncture stimulation suggest that the hemodynamic responses in the brain simultaneously reflect the sensory, cognitive, and affective dimensions of pain. This article facilitates a better understanding of acupuncture needle stimulation and its effects on specific activity changes in different brain regions as well as its relationship to the multiple dimensions of pain. Future studies can build on this meta-analysis and will help to elucidate the clinically relevant therapeutic effects of acupuncture. Copyright © 2013 American Pain Society. All rights reserved.

  15. Pen needle design influences ease of insertion, pain, and skin trauma in subjects with type 2 diabetes.

    Science.gov (United States)

    Præstmark, Kezia A; Jensen, Morten L; Madsen, Nils B; Kildegaard, Jonas; Stallknecht, Bente M

    2016-01-01

    Pen needles used for subcutaneous injections have gradually become shorter, thinner and more thin walled, and thereby less robust to patient reuse. Thus, different needle sizes, alternative tip designs and needles resembling reuse were tested to explore how needle design influences ease of insertion, pain and skin trauma. 30 subjects with injection-treated type 2 diabetes and body mass index 25-35 kg/m 2 were included in the single-blinded study. Each subject received abdominal insertions with 18 different types of needles. All needles were tested twice per subject and in random order. Penetration force (PF) through the skin, pain perception on 100 mm visual analog scale, and change in skin blood perfusion (SBP) were quantified after the insertions. Needle diameter was positively related to PF and SBP (ptrend relation. Lack of needle lubrication and small 'needle hooks' increased PF and SBP (pskin and in polyurethane rubber were linearly related, and pain outcome was dependent of SBP increase. The shape and design of a needle and the needle tip affect ease of insertion, pain and skin trauma. Relations are seen across different data acquisition methods and across species, enabling needle performance testing outside of clinical trials. NCT02531776; results.

  16. Development of a tapping device: a new needle insertion method for prostate brachytherapy

    International Nuclear Information System (INIS)

    Lagerburg, V; Moerland, M A; Konings, M K; Vosse, R E van de; Lagendijk, J J W; Battermann, J J

    2006-01-01

    The purpose of this study is to develop and test a tapping device for needle insertion for prostate brachytherapy. This device will tap the needle into the prostate with a certain, well-defined, amount of momentum, instead of the currently used method of pushing the needle. Because of the high needle insertion velocity, we expect prostate motion and deformation to be less compared to current methods. We measured the momentum that is applied when manually tapping the needle into the prostate and found a mean momentum of 0.50 ± 0.07 N s. The tapping device is pneumatically driven and we found that the delivered momentum increased linearly with the applied air pressure. The efficacy of the tapping device was tested on a piece of beef, placed on a freely moving and rotating platform. A significant correlation was found between the applied pressure and the rotation and displacement of the beef. Displacements and rotations were minimal for the highest pressure (4 bar) and amounted to only 2 mm and 6 deg., respectively. Higher air pressures will further reduce displacements and rotations

  17. Characterization of ultrasound elevation beamwidth artifacts for prostate brachytherapy needle insertion

    International Nuclear Information System (INIS)

    Peikari, Mohammad; Chen, Thomas Kuriran; Lasso, Anras; Heffter, Tamas; Fichtinger, Gabor; Burdette, Everette C.

    2012-01-01

    Purpose: Ultrasound elevation beamwidth leads to image artifacts and uncertainties in localizing objects (such as a surgical needle) in ultrasound images. The authors examined the clinical significance of errors caused by elevation beamwidth artifacts and imaging parameters in needle insertion procedures. Methods: Beveled prostate brachytherapy needles were inserted through all holes of a grid template under real-time transrectal ultrasound (TRUS) guidance. The needle tip position as indicated by the TRUS image was compared to their observed physical location. A new device was developed to measure the ultrasound elevation beamwidth. Results: Imaging parameters of the TRUS scanner have direct impact on the localization error ranging from 0.5 up to 4 mm. The smallest localization error was observed laterally close to the center of the grid template and axially within the beam's focal zone. Largest localization error occurs laterally around both sides of the grid template and axially within the beam's far field. The authors also found that the localization errors vary with both lateral and elevation offsets. Conclusions: The authors found properly adjusting the TRUS imaging settings to lower the ultrasound gain and power effectively minimized the appearance of elevation beamwidth artifacts and in turn reduced the localization errors of the needle tip.

  18. Factors influencing diagnostic yield of CT-guided percutaneous core needle biopsy for bone lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2014-01-01

    Aim: To evaluate the factors influencing diagnostic yield of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for bone lesions. Materials and methods: Between September 2005 and July 2011, 162 consecutive CT-guided CNB procedures were performed in 155 patients. The variables analysed were age, sex, lesion location, lesion type, lesion size, specimen size, biopsy needle gauge, and individual radiologist. The factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were determined by multivariate analysis of variables. Results: The diagnostic yield was 81.5%. Diagnostic yield was 89.9% for lytic bone lesions and 48.5% for sclerotic bone lesions (p < 0.001), and 89.2% for lesions ≥3 cm and 73.4% for lesions <3 cm (p = 0.010). The significant factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were lesion type [p < 0.001; odds ratio (OR) for a lytic lesion was approximately 12 times higher than that for a sclerotic lesion; 95% confidence interval (CI): 4.22–34.01], and lesion size (p = 0.012; OR for a lesion size ≥3 cm was about five-times higher than that for a lesion size <3 cm; 95% CI: 1.42–16.71). Conclusion: Lesion type and lesion size are determining factors in diagnostic yield. The higher diagnostic yield is correlated with lytic lesion and lesion size ≥3 cm

  19. Modeling, simulation, and optimal initiation planning for needle insertion into the liver.

    Science.gov (United States)

    Sharifi Sedeh, R; Ahmadian, M T; Janabi-Sharifi, F

    2010-04-01

    Needle insertion simulation and planning systems (SPSs) will play an important role in diminishing inappropriate insertions into soft tissues and resultant complications. Difficulties in SPS development are due in large part to the computational requirements of the extensive calculations in finite element (FE) models of tissue. For clinical feasibility, the computational speed of SPSs must be improved. At the same time, a realistic model of tissue properties that reflects large and velocity-dependent deformations must be employed. The purpose of this study is to address the aforementioned difficulties by presenting a cost-effective SPS platform for needle insertions into the liver. The study was constrained to planar (2D) cases, but can be extended to 3D insertions. To accommodate large and velocity-dependent deformations, a hyperviscoelastic model was devised to produce an FE model of liver tissue. Material constants were identified by a genetic algorithm applied to the experimental results of unconfined compressions of bovine liver. The approach for SPS involves B-spline interpolations of sample data generated from the FE model of liver. Two interpolation-based models are introduced to approximate puncture times and to approximate the coordinates of FE model nodes interacting with the needle tip as a function of the needle initiation pose; the latter was also a function of postpuncture time. A real-time simulation framework is provided, and its computational benefit is highlighted by comparing its performance with the FE method. A planning algorithm for optimal needle initiation was designed, and its effectiveness was evaluated by analyzing its accuracy in reaching a random set of targets at different resolutions of sampled data using the FE model. The proposed simulation framework can easily surpass haptic rates (>500 Hz), even with a high pose resolution level ( approximately 30). The computational time required to update the coordinates of the node at the

  20. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    Science.gov (United States)

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (Ptennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  1. The diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Fuchen; Ji Hongjian; Chen Liping

    2009-01-01

    Objective: To evaluate the diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions. Methods: The clinical data of CT-guided transthoracic cutting needle biopsy in 436 patients performed in past 10 years were retrospectively analyzed. Of 436 cases with pulmonary lesions, primary lung cancer was confirmed in 341, pulmonary metastasis in 62, non-malignant lesions in 33. The diagnostic accuracy and sensitivity were statistically analyzed. The occurrence of complications was discussed. Results: The diagnostic accuracy rate and sensitivity rate in primary lung cancer group were 94.7% and 94.1% respectively, in pulmonary metastasis group were 58.2% and 51.6% respectively and in non-malignant lesions group were 57.6% and 57.6% respectively. The successful rate of biopsy was 97.9%. The occurrence of complications was 15.6%. Conclusion: CT-guided percutaneous transthoracic cutting needle biopsy is a safe and valuable diagnostic technique with high diagnostic accuracy and less complications. It is very helpful in confirming the diagnosis in the patients with suspected primary pulmonary cancer, although the technical procedures need to be further improved for metastatic and non-malignant lung lesions. (authors)

  2. Effect of Needle Aspiration of Pneumothorax on Subsequent Chest Drain Insertion in Newborns

    DEFF Research Database (Denmark)

    Murphy, Madeleine C; Heiring, Christian; Doglioni, Nicoletta

    2018-01-01

    Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating pneumotho......Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating...... was 5 tertiary European neonatal intensive care units. Infants receiving respiratory support (endotracheal ventilation, continuous positive airway pressure, or supplemental oxygen >40%) who had a pneumothorax on CR that clinicians deemed needed treatment were eligible for inclusion. Interventions...... was inserted if clinicians deemed that the response was inadequate. For CD insertion, a drain was inserted between the ribs and was left in situ. Main Outcomes and Measures: The primary outcome was whether a CD was inserted on the side of the pneumothorax within 6 hours of diagnosis. Results: A total of 76...

  3. Clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy insertion.

    Science.gov (United States)

    Stewart, Jessica K; Smith, Tony P; Kim, Charles Y

    To determine the clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy (PCN) insertion. Collecting system hematoma burden was retrospectively assessed for 694 PCN insertions in 502 patients. Pelvicaliceal hematoma formation occurred in 146 kidneys (21%) in 136 patients. Clinically significant blood loss occurred in 3 patients with hematomas within one week compared to 4 patients without hematomas (p=0.39). Twenty-four patients with hematomas underwent catheter exchange within one week, compared to 55 patients without hematomas (p=0.49). Pelvicaliceal hematoma formation after PCN insertion is not uncommon and is associated with very rare clinical sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Percutaneous Needle Aspiration Is A Minimally Invasive Method For A Breast Abscess

    Directory of Open Access Journals (Sweden)

    Hamid H. Sarhan

    2012-04-01

    Results: Twenty-three (53.4% of the patients obtained complete resolution (no focal collection after one aspiration; 9 (21% required two aspirations and 8 (18.6% required more than two aspirations for the cure (residual collection. In 3 (7% of the patients, the treatment failed, where symptoms had not resolved after 3 days, with further pus collection despite aspiration and antibiotics, where surgical drainage was required. Conclusions: Percutaneous needle drainage of breast abscesses after preliminary breast US is feasible as a primary and definitive treatment for breast abscesses, if complete or near complete drainage is achieved. [Arch Clin Exp Surg 2012; 1(2.000: 105-109

  5. Lymphography with percutaneous fine needle cytology for the detection of malignant lymph node involvement

    International Nuclear Information System (INIS)

    Fencl, P.; Mylbachr, L.; Neradov, M.; Starek, J.; Doleckova, M.

    1988-01-01

    The authors present their experience of lymphograpy and percutaneous fine needle cytological biopsy of 60 patients with malignancies. Cytological specimens were taken from 98 lymph nodes in patients with cervical cancer (36), vulvar cancer (2), uterine sarcoma (2), vesical cancer (2), prostate gland cancer (3), Hodgkin's lymphoma (4), non Hodgkin's lymphoma (6), seminoma (4), lung cancer (1). Malignant cells were found in 31 persons in 41 nodes. Half of the dubious lymphography nodes had malignant cells in the biopsy material. Curiously enough, the contrast medium causes granulomatous inflammation of time-dependent intensity. 3 refs.; 2 figs.; 2 tabs

  6. Haptic sensitivity in needle insertion: the effects of training and visual aid

    Directory of Open Access Journals (Sweden)

    Dumas Cedric

    2011-12-01

    Full Text Available This paper describes an experiment conducted to measure haptic sensitivity and the effects of haptic training with and without visual aid. The protocol for haptic training consisted of a needle insertion task using dual-layer silicon samples. A visual aid was provided as a multimodal cue for the haptic perception task. Results showed that for a group of novices (subjects with no previous experience in needle insertion, training with a visual aid resulted in a longer time to task completion, and a greater applied force, during post-training tests. This suggests that haptic perception is easily overshadowed, and may be completely replaced, by visual feedback. Therefore, haptic skills must be trained differently from visuomotor skills.

  7. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    International Nuclear Information System (INIS)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C.

    2015-01-01

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm 2 ) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  8. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2015-07-15

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm{sup 2}) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  9. Pen needle design influences ease of insertion, pain, and skin trauma in subjects with type 2 diabetes

    DEFF Research Database (Denmark)

    Præstmark, Kezia A; Jensen, Morten L; Berg Madsen, Nils

    2016-01-01

    subject and in random order. Penetration force (PF) through the skin, pain perception on 100 mm visual analog scale, and change in skin blood perfusion (SBP) were quantified after the insertions. RESULTS: Needle diameter was positively related to PF and SBP (ptrend relation...... of insertion, pain and skin trauma. RESEARCH DESIGN AND METHODS: 30 subjects with injection-treated type 2 diabetes and body mass index 25-35 kg/m(2) were included in the single-blinded study. Each subject received abdominal insertions with 18 different types of needles. All needles were tested twice per....... Lack of needle lubrication and small 'needle hooks' increased PF and SBP (pskin and in polyurethane rubber were linearly related, and pain outcome...

  10. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Si Yoon; Kwon, Jong Won [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-11-15

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect.

  11. Value of percutaneous needle biopsy of small renal tumors in patients referred for cryoablation.

    Science.gov (United States)

    Iguchi, Toshihiro; Hiraki, Takao; Gobara, Hideo; Fujiwara, Hiroyasu; Sakurai, Jun; Matsui, Yusuke; Araki, Motoo; Nasu, Yasutomo; Kanazawa, Susumu

    2017-04-01

    To retrospectively evaluate the safety and diagnostic yield of needle biopsy of small renal tumors, and the clinical consequences of performing needle biopsy in patients referred for percutaneous cryoablation before their treatment. Biopsy was performed for 120 tumors (mean diameter, 2.2 cm) in 119 patients. All procedures were divided into diagnostic and non-diagnostic biopsies. Various variables were compared between the two groups. All cryoablation procedures were divided into two groups: procedures with or without simultaneous biopsy. The rates of benign or non-diagnostic tumors in each group were compared. After performing 120 initial and eight repeat biopsies, Grade 1 bleedings occurred in 44 cases. Six tumors were non-diagnostic and 114 were pathologically diagnosed. There were no significant variables between the diagnostic and non-diagnostic biopsies. Unnecessary cryoablation was avoided in nine benign lesions by performing biopsy in advance. Cryoablation performed simultaneously with biopsy included significantly more benign or non-diagnostic tumors than cryoablation performed after biopsy (15.2% vs. 1.4%; p = .01). Percutaneous biopsy of small renal tumors referred for cryoablation was a safe procedure with high diagnostic yield. The confirmation of pathological diagnosis prior to cryoablation is necessary because patients with benign tumors can avoid unnecessary treatment.

  12. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    International Nuclear Information System (INIS)

    Sung, Si Yoon; Kwon, Jong Won

    2015-01-01

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect

  13. Comparison of needles size in pediatric renal biopsy with sono-guided percutaneous-automated gun technique

    International Nuclear Information System (INIS)

    Kim, Jong Chul; Park, Jin Yong

    1997-01-01

    To compare the efficacy of a 20-gauge and an 18-gauge needle in sono-guided percutaneous automated gun biopsy for establishing the specific diagnosis of renal parenchymal disease in pediatric kidneys. In 60 pediatric patients with renal parenchymal diseases, percutaneous sono-guided gun biopsy was performed by an experienced radiologist. In two groups of 30 patients, regardless of their age, two needle passes were performed, using alternately an 18-gauge or a 20-gauge biopsy needle. The core of renal tissue thus obtained was examined with light, immunofluorescent or electron microscopy by the renal pathologist. The mean number of intact glomeruli of whole tissue core per biopsy, as seen on the light microscopy, and post-bioptic complications were compared between the two different needle size groups. The number (mean±1 standard deviation) of glomeruli obtained per biopsy was 17±8 in the 18-gauge needle group, and 14±5 in the 20-gauge group. Between two groups, there was no major post-bioptic complication requiring specific treatment, nor a statistically significant difference in the frequency of minor complications. Even though more glomeruli were obtained with an 18-gauge needle, the number obtained with a 20-gauge needle also permitted adequate pathologic examination. Both an 18-gauge and a 20-gauge needle may thus be suitable for renal biopsy in pediatric patients

  14. Experimental evaluation of magnified haptic feedback for robot-assisted needle insertion and palpation.

    Science.gov (United States)

    Meli, Leonardo; Pacchierotti, Claudio; Prattichizzo, Domenico

    2017-12-01

    Haptic feedback has been proven to play a key role in enhancing the performance of teleoperated medical procedures. However, due to safety issues, commercially-available medical robots do not currently provide the clinician with haptic feedback. This work presents the experimental evaluation of a teleoperation system for robot-assisted medical procedures able to provide magnified haptic feedback to the clinician. Forces registered at the operating table are magnified and provided to the clinician through a 7-DoF haptic interface. The same interface is also used to control the motion of a 6-DoF slave robotic manipulator. The safety of the system is guaranteed by a time-domain passivity-based control algorithm. Two experiments were carried out on stiffness discrimination (during palpation and needle insertion) and one experiment on needle guidance. Our haptic-enabled teleoperation system improved the performance with respect to direct hand interaction of 80%, 306%, and 27% in stiffness discrimination through palpation, stiffness discrimination during needle insertion, and guidance, respectively. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Development and validation of a viscoelastic and nonlinear liver model for needle insertion

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yo [Waseda University, Consolidated Research Institute for Advanced Science and Medical Care, Shinjuku, Tokyo (Japan); Onishi, Akinori; Hoshi, Takeharu; Kawamura, Kazuya [Waseda University, Graduate School of Science and Engineering, Shinjuku (Japan); Hashizume, Makoto [Kyushu University Hospital, Center for the Integration of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Fujie, Masakatsu G. [Waseda University, Graduate School of Science and Engineering, Faculty of Science and Engineering, Shinjuku (Japan)

    2009-01-15

    The objective of our work is to develop and validate a viscoelastic and nonlinear physical liver model for organ model-based needle insertion, in which the deformation of an organ is estimated and predicted, and the needle path is determined with organ deformation taken into consideration. First, an overview is given of the development of the physical liver model. The material properties of the liver considering viscoelasticity and nonlinearity are modeled based on the measured data collected from a pig's liver. The method to develop the liver model using FEM is also shown. Second, the experimental method to validate the model is explained. Both in vitro and in vivo experiments that made use of a pig's liver were conducted for comparison with the simulation using the model. Results of the in vitro experiment showed that the model reproduces nonlinear and viscoelastic response of displacement at an internally located point with high accuracy. For a force up to 0.45 N, the maximum error is below 1 mm. Results of the in vivo experiment showed that the model reproduces the nonlinear increase of load upon the needle during insertion. Based on these results, the liver model developed and validated in this work reproduces the physical response of a liver in both in vitro and in vivo situations. (orig.)

  16. Risk factors of pneumothorax in percutaneous fine needle aspiration biopsy of the lung

    International Nuclear Information System (INIS)

    Kim, Sang Jin; Park, Kwang Joo; Shin, Hyung Cheol; Kwon, Ryang; Jo, Byung June; Oh, Sei Jung; Ahn, Chang Su; Kim, Hyung Jung

    1997-01-01

    Percutaneous fine needle aspiration biopsy is known to be a useful diagnostic method for the diagnosis of various pulmonary diseases. Its diagnostic yield is high, and it is safe, but complications such as pneumothorax can occasionally occur. We reviewed the complications arising after needle aspiration biopsy and analyzed the risk factors of pneumothorax. The medical records and radiographic studies of 157 patients with various pulmonary diseases who underwent needle aspiration biopsy of the lung between 1990 and 1996 were retrospectively reviewed. The clinical features, treatment, and courses of complications were reviewed, and risk factors of pneumothorax such as depth and size of lesion, diameter of needle, number of punctures, and obstructive pulmonary abnormalities were analyzed. Complications occurred in 40 of 157cases(25.5%), namely pneumothorax in 26(16.6%), hemoptysis in 11(7%), hemothorax in two(1.3%), and recurrence of malignancy at the site of aspiration in one(0.6%). When the patients were divided into three groups according to depth of lesion, there were significant difference in the incidence of pneumothorax;the results were as follows:less than 2cm, 12.9%;between 2 and 4cm, 24.1%;and larger than 4cm, 57.1%(p<0.05). In pulmonary function testing, FVC(Forced Vital Capacity) of patients with pneumothorax was less than that of patients without(2.6±0.9L vs 3.1±0.8L, p<0.05), but FEV1(Forced Expiratory Volume in 1 second), FEV1%(percentage of predicted FEV1), FEV1/FVC, and FVC% (percentage of predicted FVC) were not different between the two groups. The incidence of pneumothorax in patients with pleura-at-tached lesion (9%) was lower than that of those with non-attached lesion(26%, p=3D0.01). The age of patients, size of lesion, diameter of the needle, guidance methods and number of aspirations showed no significant relationship with pneumothorax. In needle aspiration biopsy of the lung, depth of lesion and passage of a needle through aerated lung are

  17. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    Science.gov (United States)

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  18. The use of computerised tomography guided percutaneous fine needle aspiration in the evaluation of solitary pulmonary nodules.

    LENUS (Irish Health Repository)

    Khan, K A

    2012-02-01

    The evaluation of a solitary pulmonary nodule (SPN) has changed over the years with increased access to percutaneous computerised tomography (CT) guided fine needle aspiration (FNA), where bronchoscopy is unhelpful. The aim of our study was to evaluate the sample adequacy, diagnostic and complication rate of CT-FNA of a SPN at our academic teaching hospital over an 18 month period. CT-FNA was performed by a radiologist, with a cytopathologist in attendance to confirm the adequacy of the sample obtained. The size of the nodule, sample material and adequacy, diagnosis and complications were recorded. A total of 101 patients were included, 54 male and the mean age was 68 +\\/- 11 years. The mean size of the SPN was 2.3 cm (range 1-11 cm). 56 (56%) patients had a right SPN, 45 (45%) had a left SPN. CT-FNA was diagnostic in 80 (80%) patients and non-diagnostic in 21 (20%) patients. The sample was insufficient for immunocytochemistry, although the morphological appearance was diagnostic in 20 (25%) of the 80 patients. Pneumothorax occurred in 26\\/101 (26%) patients post CT-FNA, of these 7 (27%) required chest drain insertion, while 19 (73%) were managed conservatively. CT FNA is a useful tool for the diagnosis of a SPN, with our diagnostic accuracy comparable to that reported in the literature. However, CT-FNA may not provide adequate sample volume to perform ancillary testing and has a moderate complication rate.

  19. High velocity pulse biopsy device enables controllable and precise needle insertion and high yield tissue acquisition.

    Science.gov (United States)

    Schässburger, Kai-Uwe; Paepke, Stefan; Saracco, Ariel; Azavedo, Edward; Ekström, Christina; Wiksell, Hans

    2018-02-01

    Minimally invasive biopsies are a cornerstone of breast cancer management with ultrasound being the preferred guidance modality. New developments in breast cancer management and advances in imaging technologies bring new challenges to current biopsy methodologies. A new biopsy device (NeoNavia® biopsy system, 14 G) was developed. It incorporates a pneumatic needle insertion mechanism that is intended to provide better control of needle progression and enable stepwise insertion without noticeable deformation or displacement of surrounding tissue as visualized under ultrasound. A new method of tissue acquisition was designed to achieve a sampling yield higher than standard methodologies. Needle dynamics was assessed on a specifically designed test bed and sampling performance was compared to a Magnum® biopsy instrument (Bard, Covington, GA, USA) in representative tissue models. The histological quality of samples obtained ex-vivo was evaluated. A pneumatic pulse was measured to accelerate the needle to a maximum velocity of 21.2 ± 2.5 m/s on a stroke length of 2.5 mm, achieving significantly higher acceleration, maximum velocity and power than current biopsy devices. Mean weight of samples obtained by the NeoNavia device were 3.5, 4.6, and 4.3 times higher when sampling was performed in turkey breast, calf thymus and swine pancreas, respectively, as compared to samples obtained with the Magnum instrument. Ex-vivo analysis indicates that the method of tissue acquisition has no apparent negative impact on the histopathologic quality of obtained samples. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Percutaneous insertion of inferior vean cava filter:clinical results of 8 patients

    International Nuclear Information System (INIS)

    Bae, Kyung Soo; Shin, Hyun Woong; Park, No Hyuck; Ryeom, Hun Kyu; Kim, Yong Joo

    1997-01-01

    To evaluate the efficacy and clinical results of percutaneous insertion of inferior vena cava(IVC) filter. Over a two year period, eight IVC filters were placed in eight patients with pulmonary thromboembolism resulting from deep vein thrombosis of the legs. The indications for placement were contraindication to anticoagulation(3), and recurrent pulmonary embolism during anticoagulant therapy(5). Both femoral(7) and jugular(1) routes were used for percutaneous transvenous insertion. To delineate the caval anatomy and to ensure placement just caudal to the renal vein, a cavogram was obtained before filter placement. Bird's Nest (7) and Greenfield (1) filters were inserted. Follow-up information was obtained by means of duplex sonography, CT scan, abdominal radiograph, and perfusion scan of the lungs, followed by clinical evaluation. In all cases, procedures were technically successful. Placement complications occurred in three patients. In one, the filter was inadvertently placed above the iliac bifurcation; in the other two, prolapse of the Bird's Nest filter wire occurred. Occlusion of IVC occurred in two patients, and recurrent pulmonary embolism was suspected in one, who suffered from chest pain and short-ness of breath. In the other patients, there was no clinical evidence of recurrence of the pulmonary embolism. Insertion of an inferior vena cava filter is a safe and effective method for the prevention of pulmonary embolism when anticoagulant therapy is either ineffective or contraindicated

  1. Crural Amputation of a Newborn as a Consequence of Intraosseous Needle Insertion and Calcium Infusion

    DEFF Research Database (Denmark)

    Oesterlie, Gorm Erlend; Petersen, Klaus Kjaer; Knudsen, Lars

    2014-01-01

    Intraosseous needle insertion and infusion is considered an easy and reliable method of achieving a vascular access in acute circulatory collapse where other methods have not been successful within reasonable time. Complications are considered few but may be serious. We present a case of a newborn...... girl, where intraosseous cannulation of the tibia was lifesaving. Despite following most standard recommendations, the treatment resulted in transtibial amputation due to necrosis. We suspect that the necrosis was a consequence of extravasation of tissue-toxic calcium infusion....

  2. Immediate percutaneous sacroiliac screw insertion for unstable pelvic fractures: is it safe enough?

    Science.gov (United States)

    Acker, A; Perry, Z H; Blum, S; Shaked, G; Korngreen, A

    2018-04-01

    The purpose of this study was to compare the results of immediate and delayed percutaneous sacroiliac screws surgery for unstable pelvic fractures, regarding technical results and complication rate. Retrospective study. The study was conducted at the Soroka University Medical center, Beer Sheva, Israel, which is a level 1 trauma Center. 108 patients with unstable pelvic injuries were operated by the orthopedic department at the Soroka University Medical Center between the years 1999-2010. A retrospective analysis found 50 patients with immediate surgery and 58 patients with delayed surgery. Preoperative and postoperative imaging were analyzed and data was collected regarding complications. All patients were operated on by using the same technique-percutaneous fixation of sacroiliac joint with cannulated screws. The study's primary outcome measure was the safety and quality of the early operation in comparison with the late operation. A total of 156 sacroiliac screws were inserted. No differences were found between the immediate and delayed treatment groups regarding technical outcome measures (P value = 0.44) and complication rate (P value = 0.42). The current study demonstrated that immediate percutaneous sacroiliac screw insertion for unstable pelvic fractures produced equally good technical results, in comparison with the conventional delayed operation, without additional complications.

  3. Platelet-Rich Plasma Injection With Percutaneous Needling for Recalcitrant Lateral Epicondylitis: Comparison of Tenotomy and Fenestration Techniques.

    Science.gov (United States)

    Gaspar, Michael P; Motto, Michael A; Lewis, Sarah; Jacoby, Sidney M; Culp, Randall W; Lee Osterman, A; Kane, Patrick M

    2017-12-01

    Recalcitrant lateral epicondylitis (LE) is a common debilitating condition, with numerous treatment options of varying success. An injection of platelet-rich plasma (PRP) has been shown to improve LE, although it is unclear whether the method of needling used in conjunction with a PRP injection is of clinical importance. To determine whether percutaneous needle tenotomy is superior to percutaneous needle fenestration when each is combined with a PRP injection for the treatment of recalcitrant LE. Cohort study; Level of evidence, 3. A total of 93 patients with recalcitrant LE were treated with a PRP injection and percutaneous needle fenestration (n = 45) or percutaneous needle tenotomy (n = 48) over a 5-year study interval. Preoperative patient data, including visual analog scale for pain (VAS-P), Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Tennis Elbow Evaluation (PRTEE) scores and grip strength, were obtained from a chart review and compared with postoperative values obtained prospectively. Secondary outcomes included the incidence of complications, need for additional interventions, return to work, and patient satisfaction. At a mean follow-up of 40 months, significant improvements in VAS-P (mean, -6.1; 95% CI, -6.8 to -5.5; P < .0001), QuickDASH (mean, -46; 95% CI, -52 to -40; P < .0001), and PRTEE (mean, -57; 95% CI, -64 to -50; P < .0001) scores and grip strength (mean, +6.1 kg; 95% CI, 4.9 to 7.3; P < .0001) were observed across the entire study cohort, with no significant differences noted between the fenestration and tenotomy groups. Nine of 45 patients (22%) underwent additional procedures to treat recurrent symptoms in the fenestration group compared with 5 of 48 patients (10%) in the tenotomy group ( P = .05). No complications occurred in any patients, and no patients expressed dissatisfaction with their treatment course. A PRP injection with concomitant percutaneous needling is an effective treatment for recalcitrant

  4. Platelet-Rich Plasma Injection With Percutaneous Needling for Recalcitrant Lateral Epicondylitis: Comparison of Tenotomy and Fenestration Techniques

    Science.gov (United States)

    Gaspar, Michael P.; Motto, Michael A.; Lewis, Sarah; Jacoby, Sidney M.; Culp, Randall W.; Lee Osterman, A.; Kane, Patrick M.

    2017-01-01

    Background: Recalcitrant lateral epicondylitis (LE) is a common debilitating condition, with numerous treatment options of varying success. An injection of platelet-rich plasma (PRP) has been shown to improve LE, although it is unclear whether the method of needling used in conjunction with a PRP injection is of clinical importance. Purpose: To determine whether percutaneous needle tenotomy is superior to percutaneous needle fenestration when each is combined with a PRP injection for the treatment of recalcitrant LE. Study Design: Cohort study; Level of evidence, 3. Methods: A total of 93 patients with recalcitrant LE were treated with a PRP injection and percutaneous needle fenestration (n = 45) or percutaneous needle tenotomy (n = 48) over a 5-year study interval. Preoperative patient data, including visual analog scale for pain (VAS-P), Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Tennis Elbow Evaluation (PRTEE) scores and grip strength, were obtained from a chart review and compared with postoperative values obtained prospectively. Secondary outcomes included the incidence of complications, need for additional interventions, return to work, and patient satisfaction. Results: At a mean follow-up of 40 months, significant improvements in VAS-P (mean, –6.1; 95% CI, –6.8 to –5.5; P < .0001), QuickDASH (mean, –46; 95% CI, –52 to –40; P < .0001), and PRTEE (mean, –57; 95% CI, –64 to –50; P < .0001) scores and grip strength (mean, +6.1 kg; 95% CI, 4.9 to 7.3; P < .0001) were observed across the entire study cohort, with no significant differences noted between the fenestration and tenotomy groups. Nine of 45 patients (22%) underwent additional procedures to treat recurrent symptoms in the fenestration group compared with 5 of 48 patients (10%) in the tenotomy group (P = .05). No complications occurred in any patients, and no patients expressed dissatisfaction with their treatment course. Conclusion: A PRP injection

  5. Needle track seeding after percutaneous microwave ablation of malignant liver tumors under ultrasound guidance: Analysis of 14-year experience with 1462 patients at a single center

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jie, E-mail: yu-jie301@hotmail.com [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Liang, Ping, E-mail: liangping301@hotmail.com [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Yu, Xiao-ling, E-mail: dyuxl301@yahoo.com.cn [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Cheng, Zhi-gang, E-mail: qlczg@hotmail.com [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Han, Zhi-yu, E-mail: hanzhiyu301@hotmail.com [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Dong, Bao-wei, E-mail: dongbw301@yahoo.com [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China)

    2012-10-15

    Objective: To determine the incidence and risk factors associated with needle tract seeding after percutaneous microwave ablation (MWA) of liver cancer under ultrasound guidance. Materials and methods: Over a 14-year period, a total of 1462 patients with 2530 malignant nodules were treated by MWA. The influence of age, sex, Child-pugh classification, tumor size, tumor position, previous biopsy, insertion number and antenna type on the risk of neoplastic seeding was assessed. The survival of seeding patients after the MWA was analyzed. Results: Eleven patients with 12 nodules (0.47% per tumor, 0.75% per patient) were identified with needle tract seeding with an interval time of 6–37 (median 10) months after MWA. The mean size of the seeding nodule was 2.3 ± 0.7 cm (from 1.3 to 3.9 cm). Only previous biopsy was significantly associated with neoplastic seeding (P = 0.02). All the seeding lesions were successfully treated by resection, MWA, radiation or high intensity focus ultrasound. The median survival period of the 11 patients after the MWA was 36.0 months. The cumulative survival rates of the 11 patients after the MWA at 1-, 2-, 3-, 4- and 5-year were 90.9%, 72.7%, 62.3%, 31.2% and 15.6%, respectively. Conclusion: The results showed that the neoplastic seeding was a low risk complication of percutaneous MWA of liver cancer and was considered acceptable in general.

  6. The effects of lavender aromatherapy on pain following needle insertion into a fistula in hemodialysis patients.

    Science.gov (United States)

    Bagheri-Nesami, Masoumeh; Espahbodi, Fatemeh; Nikkhah, Attieh; Shorofi, Seyed Afshin; Charati, Jamshid Yazdani

    2014-02-01

    This study sought to determine the effects of lavender aromatherapy on pain following needle insertion into a fistula in patients undergoing hemodialysis. This is a randomized controlled clinical trial in which 92 patients undergoing hemodialysis with arteriovenous fistulas were randomly divided into two groups. The experimental-group patients inhaled lavender essence with a concentration of 10% for 5 min during 3 hemodialysis sessions, while the control-group patients received aromatherapy free of lavender essence. The mean VAS pain intensity score in the experimental and control groups before the intervention was 3.78 ± 0.24 and 4.16 ± 0.32, respectively (p = 0.35). The mean VAS pain intensity score in the experimental and control groups after three aromatherapy sessions was 2.36 ± 0.25 and 3.43 ± 0.31, respectively (p = 0.009). Lavender aromatherapy may be an effective technique to reduce pain following needle insertion into a fistula in hemodialysis patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Diagnostic Ability of Percutaneous Needle Biopsy Immediately After Radiofrequency Ablation for Malignant Lung Tumors: An Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Takaaki, E-mail: t-hasegawa@aichi-cc.jp [Aichi Cancer Center Hospital, Department of Diagnostic and Interventional Radiology (Japan); Kondo, Chiaki [Aichi Cancer Center Hospital, Department of Pathology and Molecular Diagnosis (Japan); Sato, Yozo; Inaba, Yoshitaka; Yamaura, Hidekazu; Kato, Mina; Murata, Shinichi; Onoda, Yui [Aichi Cancer Center Hospital, Department of Diagnostic and Interventional Radiology (Japan); Kuroda, Hiroaki; Sakao, Yukinori [Aichi Cancer Center Hospital, Department of Thoracic Surgery (Japan); Yatabe, Yasushi [Aichi Cancer Center Hospital, Department of Pathology and Molecular Diagnosis (Japan)

    2016-08-15

    PurposeTo evaluate the safety and diagnostic ability of percutaneous needle biopsy performed immediately after lung radiofrequency ablation (RFA).Materials and MethodsFrom May 2013 to April 2014, percutaneous needle biopsy was performed immediately after RFA for 3 patients (2 men and 1 woman, aged 57–76 years) who had lung tumors measuring 1.3–2.6 cm in diameter. All patients had prior history of malignancy, and all tumors were radiologically diagnosed as malignant. Obtained specimens were pathologically classified using standard hematoxylin and eosin staining.ResultsWe completed three planned sessions of RFA followed by percutaneous needle biopsy, all of which obtained tumor tissue that could be pathologically diagnosed. Two tumors were metastatic from renal clear cell carcinoma and rectal adenocarcinoma, respectively; one tumor was primary lung adenocarcinoma. There was no death or major complication related to the procedures. Although pneumothorax occurred in two patients, these resolved without the need for aspiration or chest tube placement. Tumor seeding was not observed, but 21 months after the procedure, one case developed local tumor progression that was treated by additional RFA.ConclusionPathologic diagnosis was possible by needle biopsy immediately after RFA for lung tumors. This technique may reduce the risks and efforts of performing biopsy and RFA on separate occasions.

  8. [Use of percutaneous needles in the feasability of single-port laparoscopic cholecystectomy].

    Science.gov (United States)

    Dávila, Fausto; Tsin, Daniel; González, Gloria; Dávila, M Ruth; Lemus, José; Dávila, Ulises

    2014-04-01

    The usefulness of percutaneous needles (PN) to replace traditional assistance ports in mini-invasive techniques with a single port is analyzed and their feasibility for conducting a single port laparoscopic cholecystectomy (SPLC) is demonstrated. A retrospective, linear and descriptive study covering 2,431 patients with a diagnosis of acute and non-acute gallbladder disease has been conducted. The patients underwent a single port laparoscopic cholecystectomy using some type of PNs, replacing the assisting ports used in traditional laparoscopic cholecystechtomy (TLC). Based on the progressive use of PNs-reins (R), hooked needles (HN) and passing suture needles (PSN)-to carry out the SPLC technique, 3 groups have been established: A, B and C. The results were compared using a Student T test, odds ratio and CI and were analyzed by means of the SPSS software v. 13.0. The use of PNs showed an increased feasibility for the laparoscopic procedure, as they were included in the surgical technique. The R were useful when carrying out the SPLC in 78% of the cases and when the HK were added, the results increased to 88%. When using the 3 types (R, HN and PSN), the results increased by 96%. Statistical significance was obtained with these values: chi 2=67.13 and P<.001; odds ratio and 95% CI became significant when comparing the B/C, A/C, and A-B/C groups. The PNs, replacing the assisting ports in laparoscopy, make it possible to attain a feasibility of the process in 96% of the cases. This percentage was similar to what is achieved with the TLC, which places the one port laparoscopy surgery technique as an advantageous and economic alternative. This application of the PNs could be made extensive to other single-port techniques, with a multi-valve platform and natural orifice surgery. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  9. Ureteral obstructions treatment with percutaneous translumbar insertion of double J endoprostheses. First remote results

    Energy Technology Data Exchange (ETDEWEB)

    Gandini, G; Asnaghi, R; Righi, D and others

    1987-01-01

    Percutaneous insertion of ureteral stents is a widely accepted method for ureteral obstructions treatment. from 1981 to February 1986, we introduced 78 endoprostheses in 60 patients. Fifty-six with malignant tumours and 4 with benign stenoses. In 48 of those 60 patients follow-up is complete. In the patients with malignant obstructions the mean time of survival was 198 days. Twelve patients were still alive in February 1986, with a mean time of survival over 300 days. In 12 patients (25%) the stent became obstructed in a mean time of 96.8 days. The placement of ureteral stents offers an alternative treatment to the palliative urologic surgery. 27 refs.

  10. Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

    Energy Technology Data Exchange (ETDEWEB)

    Veltri, Andrea, E-mail: andrea.veltri@unito.it; Busso, Marco; Sardo, Diego; Angelino, Valeria; Priola, Adriano M. [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Novello, Silvia [University of Torino, Department of Oncology, San Luigi Gonzaga Hospital (Italy); Barba, Matteo [University of Torino, Department of Radiology, San Luigi Gonzaga Hospital (Italy); Gatti, Gaia; Righi, Luisella [University of Torino, Department of Pathology, San Luigi Gonzaga Hospital (Italy)

    2017-06-15

    PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

  11. Percutaneous tenotomy: development of a novel, percutaneous, ultrasound-guided needle-cutting technique for division of tendons and other connective tissue structures

    International Nuclear Information System (INIS)

    Hopkins, James; Sampson, Matthew

    2014-01-01

    A variety of surgical procedures derive therapeutic benefit from the division of retinacular, ligamentous or tendinous structures. Examples include carpal tunnel release for median nerve impingement, annular pulley release for trigger finger and tendon division for spastic muscular contractures. Here, using an animal cadaveric model, we describe the first steps in determining the feasibility of a novel, percutaneous, ultrasound-guided needle-cutting technique to achieve the same ends. The technique we describe involves the creation of an effective needle tenotomy device via a simple modification to an 18G coaxial, beveled needle. The technique holds promise for the development of a minimally invasive alternative approach that utilises readily available technology and equipment with minimisation of morbidity and cost associated with open procedures.

  12. Dynamic analysis of a needle insertion for soft materials: Arbitrary Lagrangian-Eulerian-based three-dimensional finite element analysis.

    Science.gov (United States)

    Yamaguchi, Satoshi; Tsutsui, Kihei; Satake, Koji; Morikawa, Shigehiro; Shirai, Yoshiaki; Tanaka, Hiromi T

    2014-10-01

    Our goal was to develop a three-dimensional finite element model that enables dynamic analysis of needle insertion for soft materials. To demonstrate large deformation and fracture, we used the arbitrary Lagrangian-Eulerian (ALE) method for fluid analysis. We performed ALE-based finite element analysis for 3% agar gel and three types of copper needle with bevel tips. To evaluate simulation results, we compared the needle deflection and insertion force with corresponding experimental results acquired with a uniaxial manipulator. We studied the shear stress distribution of agar gel on various time scales. For 30°, 45°, and 60°, differences in deflections of each needle between both sets of results were 2.424, 2.981, and 3.737mm, respectively. For the insertion force, there was no significant difference for mismatching area error (p<0.05) between simulation and experimental results. Our results have the potential to be a stepping stone to develop pre-operative surgical planning to estimate an optimal needle insertion path for MR image-guided microwave coagulation therapy and for analyzing large deformation and fracture in biological tissues. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Percutaneous Endoscopic Gastrostomy Tube Insertion in Neurodegenerative Disease: A Retrospective Study and Literature Review

    Directory of Open Access Journals (Sweden)

    Pamela Sarkar

    2017-05-01

    Full Text Available Background/Aims With the notable exceptions of dementia, stroke, and motor neuron disease, relatively little is known about the safety and utility of percutaneous endoscopic gastrostomy (PEG tube insertion in patients with neurodegenerative disease. We aimed to determine the safety and utility of PEG feeding in the context of neurodegenerative disease and to complete a literature review in order to identify whether particular factors need to be considered to improve safety and outcome. Methods A retrospective case note review of patients referred for PEG insertion by neurologists in a single neuroscience center was conducted according to a pre-determined set of standards. For the literature review, we identified references from searches of PubMed, mainly with the search items “percutaneous endoscopic gastrostomy” and “neurology” or “neurodegenerative disease.” Results Short-term mortality and morbidity associated with PEG in patients with neurological disease were significant. Age greater than 75 years was associated with poor outcome, and a trend toward adverse outcome was observed in patients with low serum albumin. Conclusions This study highlights the relatively high risk of PEG in patients with neurodegenerative disease. We present points for consideration to improve outcome in this particularly vulnerable group of patients.

  14. Predicting factors for conversion from fluoroscopy guided Percutaneous transthoracic needle biopsy to cone-beam CT guided Percutaneous transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Lee, Kang Ji; Han, Young Min; Jin, Gong Yong; Song, Ji Soo

    2015-01-01

    To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB. From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson χ 2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ± 1.57 cm, 3.40 ± 1.92 cm, 3.06 ± 1.81 cm, and 35.67 ± 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ± 1.30 cm, 2.20 ± 1.45 cm, 1.91 ± 1.99 cm, and 18.32 ± 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in

  15. CT-guided thin needles percutaneous cryoablation (PCA) in patients with primary and secondary lung tumors: A preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio, E-mail: clapusceddu@gmail.com [Division of Interventional Radiology, Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncologic Diseases, Cagliari, Zip code 09100 (Italy); Sotgia, Barbara, E-mail: barbara.sotgia@gmail.com [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Fele, Rosa Maria, E-mail: rosellafele@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Melis, Luca, E-mail: doclucamelis@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy)

    2013-05-15

    Purpose: To report the data of our initial experience with CT-guided thin cryoprobes for percutaneous cryoablation (PCA) in patients with primary and secondary pulmonary tumors. Material and methods: CT-guided thin needles PCA was performed on 34 lung masses (11 NSCLC = 32%; 23 secondary lung malignancies = 68%) in 32 consecutive patients (24 men and 8 women; mean age 67 ± 10 years) not suitable for surgical resection. Lung masses were treated using two types of cryoprobes: IceRod and IceSeed able to obtain different size of iceball. The number of probes used ranged from 1 to 5 depending on the size of the tumor. After insertion of the cryoprobes into the lesion, the PCA were performed with two 2 (91%) or 3 (9%) cycles each of 12 min of freezing followed by a 4 min active thawing phase and a 4 min passive thawing phase for each one for all treatments. Results: All cryoablation sessions were successfully completed. All primary and metastatic lung tumors were ablated. No procedure-related deaths occurred. Morbidity consisted of 21% (7 of 34) pneumothorax and 3% (1 of 34) cases asymptomatic small pulmonary hemorrhage, respectively, all of CTCAE grade 1 (Common Terminology Criteria for Adverse Events). Low density of entire lesion, central necrosis and solid mass appearance were identify in 21 (62%), 7 (21%) and 6 (17%) of cryoablated tumors, respectively. No lymphadenopathy developed in the region of treated lesions. Technical success (complete lack of enhancement) was achieved in 82%, 97% and 91% of treated lesions at 1-, 3- and 6-months CT follow-up scan, respectively (p < .000). Comparing the tumor longest diameter between the baseline and at 6 month CT images, technical success was revealed in 92% cases (p < .000). Conclusion: Our preliminary experience suggests that PCA is a feasible treatment option. Well-designed clinical trials with a larger patient population are necessary to further investigate the long-term results and prognostic factors.

  16. Percutaneous Needle Tenotomy for the Treatment of Muscle and Tendon Contractures in Adults With Brain Damage: Results and Complications.

    Science.gov (United States)

    Coroian, Flavia; Jourdan, Claire; Froger, Jérome; Anquetil, Claire; Choquet, Olivier; Coulet, Bertand; Laffont, Isabelle

    2017-05-01

    To study the results and complications of percutaneous needle tenotomy for superficial retracted tendons in patients with brain damage. Prospective observational study. University hospital. Patients with severe brain damage (N=38; mean age, 60.7y; age range, 24-93y; 21 women) requiring surgical management of contractures and eligible for percutaneous needle tenotomy were enrolled between February 2015 and February 2016. The percutaneous needle tenotomy gesture was performed by a physical medicine and rehabilitation physician trained by an orthopedic surgeon, under local or locoregional anesthesia. Treated tendons varied among patients. All patients were evaluated at 1, 3, and 6 months to assess surgical outcomes (joint range of motion [ROM], pain, and functional improvement) while screening for complications. Improvements in ROM (37/38) and contractures-related pain (12/12) were satisfactory. Functional results were satisfactory (Goal Attainment Scale score ≥0) for most patients (37/38): nursing (n=12), putting shoes on (n=8), getting in bed or sitting on a chair (n=6), verticalization (n=7), transfers and gait (n=8), and grip (n=2). Five patients had complications related to the surgical gesture: cast-related complications (n=2), hand hematoma (n=2), and cutaneous necrosis of the Achilles tendon in a patient with previous obliterative arteriopathy of the lower limbs (n=1). Percutaneous needle tenotomy yields good results in the management of selected superficial muscle and tendon contractures. The complications rate is very low, and this treatment can be an alternative to conventional surgery in frail patients with neurologic diseases. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Evaluation of the friction coefficient, the radial stress, and the damage work during needle insertions into agarose gels.

    Science.gov (United States)

    Urrea, Fabián A; Casanova, Fernando; Orozco, Gustavo A; García, José J

    2016-03-01

    Agarose hydrogels have been extensively used as a phantom material to mimic the mechanical behavior of soft biological tissues, e.g. in studies aimed to analyze needle insertions into the organs producing tissue damage. To better predict the radial stress and damage during needle insertions, this study was aimed to determine the friction coefficient between the material of commercial catheters and hydrogels. The friction coefficient, the tissue damage and the radial stress were evaluated at 0.2, 1.8, and 10mm/s velocities for 28, 30, and 32 gauge needles of outer diameters equal to 0.36, 0.31, and 0.23mm, respectively. Force measurements during needle insertions and retractions on agarose gel samples were used to analyze damage and radial stress. The static friction coefficient (0.295±0.056) was significantly higher than the dynamic (0.255±0.086). The static and dynamic friction coefficients were significantly smaller for the 0.2mm/s velocity compared to those for the other two velocities, and there was no significant difference between the friction coefficients for 1.8 and 10mm/s. Radial stress averages were 131.2±54.1, 248.3±64.2, and 804.9±164.3Pa for the insertion velocity of 0.2, 1.8, and 10mm/s, respectively. The radial stress presented a tendency to increase at higher insertion velocities and needle size, which is consistent with other studies. However, the damage work did not show to be a good predictor of tissue damage, which appears to be due to simplifications in the analytical model. Differently to other approaches, the method proposed here based on radial stress may be extended in future studies to quantity tissue damage in vivo along the entire needle track. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.

    2013-01-01

    Aim: To assess the accuracy and risk factors for complications of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for small (≤20 mm) pulmonary lesions. Materials and methods: A retrospective study was undertaken comprising 169 patients who underwent CT-guided CNB for small (≤20 mm) pulmonary lesions. To assess the accuracy of the procedure, the diagnosis at biopsy was compared with the diagnosis after definitive surgery or clinical follow-up. The risk factors for pneumothorax and bleeding were determined by multivariate analysis of variables. Results: The overall diagnostic accuracy was 93.5%. The sensitivity for malignancy and specificity for benign lesions were 90.4% and 100%, respectively. Positive and negative predictive values were 100% and 83.3%, respectively. Twenty-five patients (14.8%) had pneumothorax after CT percutaneous CNB of the lung. The significant risk factors affecting the incidence of pneumothorax were lesion–pleural distance (p = 0.008) and needle–pleural angle (p = 0.012). The highest rate of pneumothorax correlated with a lesion–pleural distance ≥21 mm (OR = 18.46; 95%CI: 2.27–149.95) and a needle–pleural angle ≥51° (OR = 8.22; 95%CI: 2.14–31.49). Bleeding occurred in 30 patients (17.8%). The only significant risk factor affecting the incidence of bleeding was lesion–pleural distance (p = 0.011). The highest bleeding rate correlated with a lesion–pleural distance ≥21 mm (OR = 7.93; 95%CI: 1.73–36.43). Conclusion: CT-guided percutaneous CNB of small (≤20 mm) pulmonary lesions provides high diagnostic accuracy with acceptable complications. A lesion–pleural distance of ≥21 mm and needle–pleural angle of ≥51° are identified as the risk factors for highest pneumothorax rate. In addition, the needle–pleural angle is a novel predictor of pneumothorax. A lesion–pleural distance of ≥21 mm is also identified as a risk factor for the highest bleeding rate.

  19. Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature

    Directory of Open Access Journals (Sweden)

    Chongjun Yang

    2018-02-01

    Full Text Available Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future.

  20. Force Modeling, Identification, and Feedback Control of Robot-Assisted Needle Insertion: A Survey of the Literature.

    Science.gov (United States)

    Yang, Chongjun; Xie, Yu; Liu, Shuang; Sun, Dong

    2018-02-12

    Robot-assisted surgery is of growing interest in the surgical and engineering communities. The use of robots allows surgery to be performed with precision using smaller instruments and incisions, resulting in shorter healing times. However, using current technology, an operator cannot directly feel the operation because the surgeon-instrument and instrument-tissue interaction force feedbacks are lost during needle insertion. Advancements in force feedback and control not only help reduce tissue deformation and needle deflection but also provide the surgeon with better control over the surgical instruments. The goal of this review is to summarize the key components surrounding the force feedback and control during robot-assisted needle insertion. The literature search was conducted during the middle months of 2017 using mainstream academic search engines with a combination of keywords relevant to the field. In total, 166 articles with valuable contents were analyzed and grouped into five related topics. This survey systemically summarizes the state-of-the-art force control technologies for robot-assisted needle insertion, such as force modeling, measurement, the factors that influence the interaction force, parameter identification, and force control algorithms. All studies show force control is still at its initial stage. The influence factors, needle deflection or planning remain open for investigation in future.

  1. Current microbiology of percutaneous endoscopic gastrostomy tube (PEG tube) insertion site infections in patients with cancer.

    Science.gov (United States)

    Rolston, Kenneth V I; Mihu, Coralia; Tarrand, Jeffrey J

    2011-08-01

    Percutaneous endoscopic gastrostomy (PEG) is frequently used to provide enteral access in cancer patients who are unable to swallow. Infection is an important complication in this setting. Current microbiological data are needed to guide infection prevention and treatment strategies. The microbiological records of our institution (a 550-bed comprehensive cancer center) were retrospectively reviewed over an 8-month study period in order to identify patients who developed PEG tube insertion site infections, and review their microbiological details and susceptibility/resistance data. Fifty-eight episodes of PEG tube insertion site infections were identified. Of these, 31 (53%) were monomicrobial, and the rest were polymicrobial. The most common organisms isolated were Candida species, Staphylococcus aureus, and Pseudomonas aeruginosa. All infections were local (cellulitis, complicated skin, and skin structure infections including abdominal wall abscess) with no cases of concomitant bacteremia being documented. Most of the organisms isolated were susceptible to commonly used antimicrobial agents, although some quinolone-resistant and some multidrug-resistant organisms were isolated. This retrospective study provides descriptive data regarding PEG tube insertion site infections. These data have helped us update institutional guidelines for infection prevention and treatment as part of our focus on antimicrobial stewardship.

  2. Immediate and short-term effects of the combination of dry needling and percutaneous TENS on post-needling soreness in patients with chronic myofascial neck pain

    Science.gov (United States)

    León-Hernández, Jose V.; Martín-Pintado-Zugasti, Aitor; Frutos, Laura G.; Alguacil-Diego, Isabel M.; de la Llave-Rincón, Ana I.; Fernandez-Carnero, Josue

    2016-01-01

    ABSTRACT Background Dry needling (DN) and percutaneous electrical nerve stimulation (PENS) are widely used techniques in the treatment of myofascial pain. Objective To investigate the immediate and short-term effects of the combination of DN and PENS compared to DN alone on the upper trapezius muscle. Method This is a 72-hour follow-up single-blinded randomized controlled trial. Sixty-two volunteer patients with chronic myofascial neck pain with active Myofascial Trigger Points (MTrPs) in the upper trapezius muscle were recruited. Randomization was performed, and 31 patients received DN treatment (DN group) and 31 received DN and PENS (DN+PENS group). The primary outcomes were neck disability index (NDI) and visual analog scale for pain for both post-needling soreness (PNS) and neck pain intensity (NPI). Pressure pain threshold (PPT) and cervical range of motion (CROM) were the secondary outcomes. Results We detected between-group differences in NPI and PNS in favor of the DN+PENS group immediately after treatment. No between-group differences in NDI were observed. Conclusion PENS application after dry needling treatment is more effective than dry needling alone for decreasing soreness in the short term and improving neck pain intensity immediately in patients with myofascial chronic neck pain. PMID:27410163

  3. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses.

    Science.gov (United States)

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-10-01

    Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate.

  4. CT-guided percutaneous injection of the fibrin glue by 'double needle' technique for the treatment of sacral cysts

    International Nuclear Information System (INIS)

    Wang Ganggang; Chen Long; Yang Chao; Ni Caifang

    2013-01-01

    Objective: To analyze the efficacy and safety of CT-guided percutaneous injection of the fibrin glue by 'double needle' technique to treat sacral cyst. Methods: Clinical data of 20 cases with 'double-needle' injection of fibrin glue technology to treat sacral cyst were retrospectively analyzed. All patients had varying degrees of sacral nerve root compression symptoms. The treatment for sacral cyst was carried out after clear diagnosis was made. On the basis of CT-guided percutaneous injection of fibrin glue, the improved CT-guided percutaneous injection of fibrin glue by 'double-needle' technique was used to treat these patients. The average dose of fibrin glue was (5.9 ± 2.4) ml. The clinical results of improvement as to pain and neurological function were evaluated after follow-up of an average of 17 months. The assessment criteria were as follows: excellent, complete resolution of signs and symptoms, with the patient returning to his or her regular employment and no recurrence of cysts during 1 year of follow-up, good, symptoms and signs in the legs and perineal region resolved but with persistent pain in the lumbosacral region, which did not interfere with the patient's regular work (the cysts did not recur for 6 months during follow-up), fair, no improvement in clinical symptoms, but a decrease in cyst size on the imaging study, poor, no improvement in clinical symptoms and no observed changes in cyst size in imaging studies or recurrence. Results: Most patients experienced some degree of pain relief and functional improvement after fibrin glue therapy, with most experiencing complete or marked resolution of clinical symptoms. Nine patients reported excellent recovery, 8 reported good recovery, 2 reported fair recovery, and 1 reported poor recovery. The overall percentage of positive outcomes (excellent and good recovery) was 85%. No serious postoperative complications were discovered. Conclusions: CT guided percutaneous injection of the fibrin glue by

  5. Fine-needle percutaneous transhepatic parenchymal portal venography by using carbon dioxide: a pilot study in pigs

    International Nuclear Information System (INIS)

    Sun, Fei; Hernandez, Javier; Crisostomo, Veronica; Pineda, Luis-Fernando; Lima, Juan Rafael; Uson, Jesus; Maynar, Manuel

    2003-01-01

    Our purpose was to evaluate the feasibility and safety of carbon dioxide (CO 2 ) in fine-needle percutaneous transhepatic parenchymal portal venography and its potential clinical applications. Three Belgian landrace pigs received fine-needle percutaneous transhepatic parenchymal portal venography by using CO 2 as a contrast agent. Under fluoroscopic and B-mode ultrasonic guidance, right or left lobe of liver was punctured with a 22-G Chiba needle, through which CO 2 was injected with a dedicated CO 2 injector at injection rate of 20 ml/s for 20 ml, 40 ml/s for 40 ml, 40 ml/s for 60 ml, and 40 ml/s for 80 ml, respectively. The portal venograms were obtained by use of digital subtraction angiography (DSA) system with animal in supine position. In one pig transarterial portal venography was performed, in addition, using iodinated contrast agent. The portal vein was visualized in each run of venography. Optimal images of portal tree structure up to four-order branches were obtained in all those with CO 2 injection rate of 40 ml/s, which appeared much better in quality than those obtained by cranial mesenteric arteriography with iodinated contrast agent. No extravasation of CO 2 , liver laceration, or any other complication occurred during the procedures. The technique we proposed demonstrated optimal portography, which appeared to be safe, minimally invasive, less time-consuming, cost-effective, and easy to perform, with great potential in clinical applications. (orig.)

  6. Use of percutaneous image-guided coaxial core-needle biopsy for diagnosis of intraabdominal lymphoma

    International Nuclear Information System (INIS)

    Shimizu, Ikuo; Okazaki, Yoichi; Takeda, Wataru; Kirihara, Takehiko; Sato, Keijiro; Fujikawa, Yuko; Ueki, Toshimitsu; Hiroshima, Yuki; Sumi, Masahiko; Ueno, Mayumi; Ichikawa, Naoaki; Kobayashi, Hikaru

    2014-01-01

    Although pathological diagnosis is essential for managing malignant lymphoma, intraabdominal lesions are generally difficult to approach due to the invasiveness of abdominal surgery. Here, we report the use of percutaneous image-guided coaxial core-needle biopsy (CNB) to obtain intraabdominal specimens for diagnosing intraabdominal lymphomas, which typically requires histopathological and immunohistochemical evaluation. We retrospectively reviewed consecutive cases involving computed tomography (CT)- or ultrasonography (US)-guided CNB to obtain pathological specimens for intraabdominal lesions from 1999 to 2011. Liver, spleen, kidney, and inguinal node biopsies were excluded. We compared CNBs with laparotomic biopsies. A total of 66 CNBs were performed for 59 patients (32 males, 27 females; median age, 63.5), including second or third repeat procedures. Overall diagnostic rate was 88.5%. None of the patients required additional surgical biopsies. Notably, the median interval between recognition of an intraabdominal mass and biopsy was only 1 day. Forty-five procedures were performed for hematological malignancies. Adequate specimens were obtained for histopathological diagnosis in 86% of cases. Flow cytometry detected lymphoma cells in 79.5% of cases. Twelve patients (nine males, three females; median age, 60) were eligible for surgical biopsy. While every postoperative course was satisfactory, median duration from lesion recognition to therapy initiation for lymphoma cases was significantly shorter for CNB than for surgical biopsy (14 vs. 35 days). While one-fourth of the patients were not eligible for the procedures, CNB is safe and highly effective for diagnosis of intraabdominal lymphomas. This method significantly improves sampling and potentially helps attain immunohistological distinction, allowing for more timely therapy initiation

  7. Robust path planning for flexible needle insertion using Markov decision processes.

    Science.gov (United States)

    Tan, Xiaoyu; Yu, Pengqian; Lim, Kah-Bin; Chui, Chee-Kong

    2018-05-11

    Flexible needle has the potential to accurately navigate to a treatment region in the least invasive manner. We propose a new planning method using Markov decision processes (MDPs) for flexible needle navigation that can perform robust path planning and steering under the circumstance of complex tissue-needle interactions. This method enhances the robustness of flexible needle steering from three different perspectives. First, the method considers the problem caused by soft tissue deformation. The method then resolves the common needle penetration failure caused by patterns of targets, while the last solution addresses the uncertainty issues in flexible needle motion due to complex and unpredictable tissue-needle interaction. Computer simulation and phantom experimental results show that the proposed method can perform robust planning and generate a secure control policy for flexible needle steering. Compared with a traditional method using MDPs, the proposed method achieves higher accuracy and probability of success in avoiding obstacles under complicated and uncertain tissue-needle interactions. Future work will involve experiment with biological tissue in vivo. The proposed robust path planning method can securely steer flexible needle within soft phantom tissues and achieve high adaptability in computer simulation.

  8. Design and Kinematic Analysis of a New End-Effector for a Robotic Needle Insertion-Type Intervention System

    Directory of Open Access Journals (Sweden)

    Youngjin Moon

    2014-12-01

    Full Text Available This paper presents a new end-effector as a key component for a robotic needle insertion-type intervention system and its kinematic analysis. The mechanism is designed as a spherical mechanism with a revolute joint and a curved sliding joint, and its links always move on the surface of a sphere. The remote centre of motion (RCM of the designed mechanism is placed below the base of the mechanism to avoid contact with the patient's body, unlike the conventional end-effectors developed for needle insertion. For the proposed mechanism, the forward kinematics are solved in terms of input joint parameters and then the reverse kinematics are solved by using the cross-product relationship between each joint vector and a vector mutually perpendicular to the vectors. The kinematic solutions are confirmed by numerical examples.

  9. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Oda, Miyo; Ito, Katsuhide

    2010-09-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: "none", "mild", "moderate" and "severe". The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p < 0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax.

  10. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method

    International Nuclear Information System (INIS)

    Kakizawa, Hideaki; Hieda, Masashi; Oda, Miyo; Toyota, Naoyuki; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Ito, Katsuhide

    2010-01-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: 'none', 'mild', 'moderate' and 'severe'. The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p<0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax. (author)

  11. Percutaneous insertion of peritoneal dialysis catheters using ultrasound and fluoroscopic guidance: A single centre experience and review of literature

    International Nuclear Information System (INIS)

    De Boo, Diederick W.; Mott, Nigel; Tregaskis, Peter; Quach, Trung; Menahem, Solomon; Walker, Rowan G.; Koukounaras, Jim

    2015-01-01

    Various methods of peritoneal dialysis (PD) catheter insertion are available. The purpose of this study was to evaluate a percutaneous insertion technique using ultrasound (US) and fluoroscopy performed under conscious sedation and as day case procedure. Data of 87 percutaneous inserted dialysis catheters were prospectively collected, including patients' age, gender, body mass index, history of previous abdominal surgery and cause of end stage renal failure. Length of hospital stay, early complications and time to first use were also recorded. Institutional review board approval was obtained. A 100% technical success rate was observed. Early complications included bleeding (n = 3), catheter dysfunction (n = 6), exit site infection (n = 1) and exit site leakage (n = 1). All cases of catheter dysfunction and one case of bleeding required surgical revision. Median time of follow-up was 18 months (range 3–35), and median time from insertion to first use was days 14 (1–47). Of the 82 patients who started dialysis, 20 (23%) ceased PD at some stage during follow-up. Most frequently encountered reasons include deteriorating patient cognitive or functional status (n = 5), successful transplant kidney (n = 4) and pleuro-peritoneal fistula (n = 4). Sixty-two (71%) PD catheter insertions were performed as day case. The remaining insertions were performed on patients already admitted to the hospital. Percutaneous insertion of dialysis catheter using US and fluoroscopy is not only safe but can be performed as day case procedure in most patients, even with a medical history of abdominal surgery and/or obesity.

  12. Treatment of biliary stricture by percutaneous transhepatic insertion of metallic stent

    International Nuclear Information System (INIS)

    He Xiaofeng; Shan Hong; Chen Yong; Li Yanhao

    1997-01-01

    Purpose: Percutaneous transhepatic insertion of biliary stent (PTIBS) was adopted for treating malignant and benign biliary stricture. The therapeutic effect, technique and complications were investigated. Materials and methods: Twenty-five patients with biliary stricture were treated by PTIBS, including hilar biliary cancer 16 cases, pancreatic cancer 4 cases, hilar metastatic cancer 3 cases, and post-operative biliary stricture of bile duct 2 cases. Results: The technical success rate was 96.0% (24/25). Two stents were placed in the right and left hepatic ducts respectively in 2 cases. The survival rate of 6 and 12 months were 73.3% and 46.6%. Restenosis rate was 40.0% in 6 months. Mild hemobilia (44.0%) and retrograde infection (8.0%) were the main complications which could be managed by conservative treatment. Conclusion: It was suggested that PTIBS was a safe and effective method in the treatment of biliary stricture. There was higher success rate of PTIBS as compared to endoscopic retrograde biliary, approach especially in patients with hilar biliary stricture. If combined with chemotherapy, the survival rate of malignant biliary stricture could be further improved

  13. Percutaneous needle aspiration biopsy (PCNA) of pulmonary lesions: evaluation of a reaspiration or a rebiopsy (second PCNA)

    International Nuclear Information System (INIS)

    Lee, In Jae; Kim, Dong Gyu; Jung, Ki Suck; Koh, Sung Hye; Jeon, Eui Yong; Lee, Kwan Seop; Lee, Yul; Bae, Sang Hoon; Im, Hyoung June

    2008-01-01

    To evaluate the effectiveness of the reaspiration or rebiopsy of pulmonary lesions (second PCNA) in cases where the pathologic results are inconclusive upon initial percutaneous needle aspiration biopsy (PCNA). A total of 364 PCNA cases (350 initial PCNA, 14 second PCNA) were performed under CT or fluoroscopy guidance for all the 350 patients enrolled. The procedure was performed by either using an automated biopsy gun with a 20-G needle (298 cases) or a 20-G aspiration needle (66 cases). The pathologic agreement rates between the initial and second PCNA, as well as the causes for a second PCNA, were evaluated. Finally the type and rate of complication were also evaluated. The second PCNA rate was 4.0% (14/350). The causes for a second PCNA, following the initial PCNA included unexpected pathologic results (n = 7) and inconclusive pathologic results (n = 7). Of the seven cases which had unexpected pathologic results from their initial PCNAs, five had similar pathologic results after a second PCNA. Also, of the seven cases of inconclusive pathologic results, such as atypical cells, the scanty cellularity or necrosis upon an initial PCNA, six cases revealed a malignancy on a second PCNA. The overall complication rate, including both the initial and second PCNAs was 14.0% (51/364). A second PCNA was performed to help resolve the exact diagnosis for a pulmonary lesion in cases of inconclusive pathologic results upon an initial PCNA

  14. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  15. Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students

    Science.gov (United States)

    de Araújo Setin, Raíza; Fortes Cirimbelli, Carolina; Mazeto Ercolin, Anna Carolina; Pires, Sâmara Turbay; Disselli, Tamiris; Ferrarini Nunes Soares Hage, Maria Cristina

    2018-01-01

    The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and…

  16. Feasibility Study of Needle Placement in Percutaneous Vertebroplasty: Cone-Beam Computed Tomography Guidance Versus Conventional Fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Braak, Sicco J., E-mail: sjbraak@gmail.com [St. Antonius Hospital, Department of Radiology (Netherlands); Zuurmond, Kirsten, E-mail: kirsten.zuurmond@philips.com; Aerts, Hans C. J., E-mail: hans.cj.aerts@philips.com [Philips Medical, Department of Clinical Development (Netherlands); Leersum, Marc van, E-mail: m.van.leersum@antoniusziekenhuis.nl; Overtoom, Timotheus T. Th., E-mail: overtm@knoware.nl; Heesewijk, Johannes P. M. van, E-mail: j.heesewijk@antoniusziekenhuis.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl [St. Antonius Hospital, Department of Radiology (Netherlands)

    2013-08-01

    ObjectiveTo investigate the accuracy, procedure time, fluoroscopy time, and dose area product (DAP) of needle placement during percutaneous vertebroplasty (PVP) using cone-beam computed tomography (CBCT) guidance versus fluoroscopy.Materials and MethodsOn 4 spine phantoms with 11 vertebrae (Th7-L5), 4 interventional radiologists (2 experienced with CBCT guidance and two inexperienced) punctured all vertebrae in a bipedicular fashion. Each side was randomization to either CBCT guidance or fluoroscopy. CBCT guidance is a sophisticated needle guidance technique using CBCT, navigation software, and real-time fluoroscopy. The placement of the needle had to be to a specific target point. After the procedure, CBCT was performed to determine the accuracy, procedure time, fluoroscopy time, and DAP. Analysis of the difference between methods and experience level was performed.ResultsMean accuracy using CBCT guidance (2.61 mm) was significantly better compared with fluoroscopy (5.86 mm) (p < 0.0001). Procedure time was in favor of fluoroscopy (7.39 vs. 10.13 min; p = 0.001). Fluoroscopy time during CBCT guidance was lower, but this difference is not significant (71.3 vs. 95.8 s; p = 0.056). DAP values for CBCT guidance and fluoroscopy were 514 and 174 mGy cm{sup 2}, respectively (p < 0.0001). There was a significant difference in favor of experienced CBCT guidance users regarding accuracy for both methods, procedure time of CBCT guidance, and added DAP values for fluoroscopy.ConclusionCBCT guidance allows users to perform PVP more accurately at the cost of higher patient dose and longer procedure time. Because procedural complications (e.g., cement leakage) are related to the accuracy of the needle placement, improvements in accuracy are clinically relevant. Training in CBCT guidance is essential to achieve greater accuracy and decrease procedure time/dose values.

  17. Percutaneous Ethanol Injection of Unresectable Medium-to-Large-Sized Hepatomas Using a Multipronged Needle: Efficacy and Safety

    International Nuclear Information System (INIS)

    Ho, C.S.; Kachura, J.R.; Gallinger, S.; Grant, D.; Greig, P.; McGilvray, I.; Knox, J.; Sherman, M.; Wong, F.; Wong, D.

    2007-01-01

    Fine needles with an end hole or multiple side holes have traditionally been used for percutaneous ethanol injection (PEI) of hepatomas. This study retrospectively evaluates the safety and efficacy of PEI of unresectable medium-to-large (3.5-9 cm) hepatomas using a multipronged needle and with conscious sedation. Twelve patients, eight men and four women (age 51-77 years; mean: 69) received PEI for hepatomas, mostly subcapsular or exophytic in location with average tumor size of 5.6 cm (range: 3.5-9.0 cm). Patients were consciously sedated and an 18G retractable multipronged needle (Quadrafuse needle; Rex Medical, Philadelphia, PA) was used for injection under real-time ultrasound guidance. By varying the length of the prongs and rotating the needle, the alcohol was widely distributed within the tumor. The progress of ablation was monitored by contrast-enhanced ultrasound, computed tomography (CT) or magnetic resonance imaging (MRI) after each weekly injection and within a month after the final (third) injection and 3 months thereafter. An average total of 63 mL (range: 20-154 ml) of alcohol was injected per patient in an average of 2.3 sessions. Contrast-enhanced CT, ultrasound, or MRI was used to determine the degree of necrosis. Complete necrosis was noted in eight patients (67%), near-complete necrosis (90-99%) in two (16.7%), and partial success (50-89%) in two (16.7%). Follow-up in the first 9 months showed local recurrence in two patients and new lesions in another. There was no mortality. One patient developed renal failure, liver failure, and localized perforation of the stomach. He responded to medical treatment and surgery was not required for the perforation. One patient had severe postprocedural abdominal pain and fever, and another had transient hyperbilirubinemia; both recovered with conservative treatment. PEI with a multipronged needle is a new, safe, and efficacious method in treating medium-to-large-sized hepatocellular carcinoma under conscious

  18. Percutaneous needle fasciotomy for Dupuytren's disease : report on a randomized clinical trial and related research

    NARCIS (Netherlands)

    Rijssen, Annet Laura van

    2012-01-01

    Het onderzoek dat is verzameld in dit proefschrift is er vooral op gericht om op gerandomiseerde wijze de selectieve fasciëctomie (SF) en de percutane naald fasciotomie (PNF) te vergelijken als behandelingsmethoden voor de ziekte van Dupuytren. Het effect van deze twee behandelingen op het totale

  19. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo [Chonnam National University Hospital, Chonnam National University Medical School, Gwangju(Korea, Republic of)

    2017-04-15

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications.

  20. Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: Tips to ensure safe and effective biopsy

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo

    2017-01-01

    Ultrasound-guided percutaneous core needle biopsy (USPCB) is used extensively in daily clinical practice for the pathologic confirmation of both focal and diffuse diseases of the abdominal viscera. As a guidance tool, US has a number of clear advantages over computerized tomography or magnetic resonance imaging: fewer false-negative biopsies, lack of ionizing radiation, portability, relatively short procedure time, real-time intra-procedural visualization of the biopsy needle, ability to guide the procedure in almost any anatomic plane, and relatively lower cost. Notably, USPCB is widely used to retrieve tissue specimens in cases of hepatic lesions. However, general radiologists, particularly beginners, find USPCB difficult to perform in abdominal organs other than the liver; indeed, a full understanding of the entire USPCB process and specific considerations for specific abdominal organs is necessary to safely obtain adequate specimens. In this review, we discuss some points and techniques that need to be borne in mind to increase the chances of successful USPCB. We believe that the tips and considerations presented in this review will help radiologists perform USPCB to successfully retrieve target tissue from different organs with minimal complications

  1. Presentation of a needle for direct or percutaneous myocardium stem cells injection

    Directory of Open Access Journals (Sweden)

    Nathan Valle Soubihe Junior

    2013-09-01

    Full Text Available The instrument has a locking mechanism and is composed of an external needle with blunt tip, with multiple 0.5 mm diameter holes. Internally it is fitted with a mandrill needle, which can be mobilized inside occluding or releasing the lateral holes. The procedure for producing micro lesions is done by exchanging the blunt mandrill for a brush-mandrill, provided with micro bristles that are structurally designed to fill the holes with small exteriorization of bristles. As an option to brush mandrill there is a second self-expandable feather shaped mandrill.

  2. Percutaneous vertebroplasty performed with an 18 G needle for the treatment of severe compression fracture of cervical vertebral body due to malignancy

    International Nuclear Information System (INIS)

    Chen Long; Ni Caifang; Wang Zhentang; Liu Yizhi; Jin Yonghai; Zhu Xiaoli; Zou Jianwei; Xiao Xiangsheng

    2010-01-01

    Objective: To investigate the clinical feasibility and efficacy of percutaneous vertebroplasty performed with an 18G needle for the treatment of severe compression fracture of cervical vertebral body due to malignancy. Methods: During the period of 2006-2010 percutaneous vertebroplasty was performed in 10 patients with severe compression fracture of cervical vertebral body due to metastatic lesions. A total of 12 diseased vertebral bodies were detected, which distributed in the C 4 (n = 3), C 5 (n = 3), C 6 (n = 4) and C 7 (n = 2) vertebral bodies. Under DSA guidance an 18G needle was punctured into the target vertebral body and then polymethylmethacrylate bone cement was injected in. A follow-up lasting for one month was conducted. Results: The technical success of both needle puncturing and bone cement injection was achieved in all patients. The mean amount of bone cement injected in each diseased vertebra was 2.2 ml(1.5-3.2)ml. Marked pain relief was quickly obtained in al1 10 patients. No major complications occurred in this series, except for asymptomatic bone cement leaking around vertebra which appeared in 4 vertebral bodies. Conclusion: Percutaneous vertebroplasty, which is performed with an 18G needle, is a safe and effective technique for the treatment of severe compression fracture of cervical vertebral body due to malignancy. (authors)

  3. Combined Treatment of Large Hepatocellular Carcinoma with Transcatheter Arterial Chemoembolization and Percutaneous Ethanol Injection with a Multipronged Needle: Experimental and Clinical Investigation

    International Nuclear Information System (INIS)

    Kawamura, Rinako; Seki, Toshihito; Umehara, Hideto; Ikeda, Kozo; Inokuchi, Ryosuke; Asayama, Toshiki; Yamaguchi, Takashi; Takahashi, Yu; Sakao, Masayuki; Lencioni, Riccardo; Okazaki, Kazuichi

    2012-01-01

    Purpose: This study was designed to evaluate the usefulness of percutaneous ethanol injection (PEI) with a multipronged needle for the treatment of large hepatocellular carcinoma (HCC). An experimental animal study and a clinical investigation were performed. Methods: In the experimental study, 20 ml of 99.5% ethanol was injected into porcine liver in vivo with a multipronged needle (n = 5) or a straight needle (n = 5), and the volumes of coagulation necrosis were compared. In the clinical investigation, PEI was performed in 17 patients (10 men, 7 women; mean age 73.4 ± 6.7 years) with single, large HCC (mean tumor diameter, 47.2 ± 11.5 mm; range, 32–70 mm) by using a multipronged needle. Fifteen of 17 patients received transarterial chemoembolization (TACE) before PEI. Results: The volume of coagulation in porcine liver in vivo was significantly increased with the multipronged needle compared with the straight needle (longest perpendicular diameters, 34.2 ± 3.6 mm × 30.2 ± 3.6 mm vs. 22.6 ± 2.5 mm × 19 ± 2.2 mm, respectively; P < 0.05). In the clinical trial, initial complete response (CR) of the tumor was achieved in 17 of 17 patients, 7 of whom required two PEI sessions. During the follow-up, local recurrence was detected in 4 of 17 patients at 3–19 months after the procedure, for a rate of sustained local CR of 76%. No major complication occurred. Conclusions: Use of a multipronged needle substantially increases the volume of coagulation in vivo with respect to the conventional PEI technique. Combined TACE and PEI with multipronged needles is a safe and effective option for percutaneous treatment of single, large HCC.

  4. Percutaneous transthoracic computed tomography-guided AICD insertion in a patient with extracardiac Fontan conduit.

    LENUS (Irish Health Repository)

    Murphy, Darra T

    2011-02-01

    Percutaneous pulmonary venous atrial puncture was performed under computed tomography guidance to successfully place an automated implantable cardiac defibrillator into a 26-year-old patient with extracardiac Fontan conduit who had presented with two out-of-hospital cardiac arrests. The procedure avoided the need for lead placement at thoracotomy.

  5. Predisposing factors of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy: comparison between CT emphysema score and pulmonary function test

    International Nuclear Information System (INIS)

    Lee, Chang Ho; Park, Kyung Joo; Park, Dong Won; Jung, Kyung Il; Suh, Jung Ho

    1997-01-01

    To compare the CT emphysema score with various factors of pulmonary function test by simple spirometry and to use the result as a predictor of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy. The CT scans of 106 patients who had undergone percutaneous transthoracic fine needle aspiration biopsy of lung lesions within the previous 18 months were retrospectively reviewed. In 75 of these 106 cases, the results of the pulmonary function test were also reviewed. On plain chest radiography, pneumothorax was noted in 20 cases (19%). Emphysema was blindly evaluated. We divided each lung into four segments and determined the severity and involved volume of emphysema, as seen on CT. Severity was classified as one of four grades, as follow : absence of emphysema=0 ; low attenuation area of less than 5mm=1 ; low attenuation area of more than 5mm, and vascular pruning with normal lung intervening=2 ; and diffuse low attenuation without intervening normal lung, and larger confluent low attenuation with vascular pruning and distortion of branching pattern occupying all or almost all the involved parenchyma=3. The involved area was also classified as one of four grades : less than 25%=1 ; 25 - 49%=2 ; 51 - 74%=3 ; and more than 75%=4. The CT emphysema score was defined as the average of the grade of severity multiplied by the grade of involved area. Pulmonary function tests, consisting of simple spirometry and a pulmonologist's interpretation, were evaluated. We also evaluated depth and size of lesion as known predisposing factors in postbioptic pneumothorax. Statistical analysis was performed using the chi-square test, Wilcoxon ranks sum W test and the student t test. A comparison between the two groups of occurrence(with or without pneumothorax) showed the emphysema scores to be 1.69±2.0 and 1.11±2.9, respectively ; there was thus no significant difference between the two groups (z= - 0.048, p>0.10). Nor were differences revealed by the pulmonary

  6. Predisposing factors of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy: comparison between CT emphysema score and pulmonary function test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Ho; Park, Kyung Joo; Park, Dong Won; Jung, Kyung Il; Suh, Jung Ho [Ajou Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-11-01

    To compare the CT emphysema score with various factors of pulmonary function test by simple spirometry and to use the result as a predictor of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy. The CT scans of 106 patients who had undergone percutaneous transthoracic fine needle aspiration biopsy of lung lesions within the previous 18 months were retrospectively reviewed. In 75 of these 106 cases, the results of the pulmonary function test were also reviewed. On plain chest radiography, pneumothorax was noted in 20 cases (19%). Emphysema was blindly evaluated. We divided each lung into four segments and determined the severity and involved volume of emphysema, as seen on CT. Severity was classified as one of four grades, as follow : absence of emphysema=0 ; low attenuation area of less than 5mm=1 ; low attenuation area of more than 5mm, and vascular pruning with normal lung intervening=2 ; and diffuse low attenuation without intervening normal lung, and larger confluent low attenuation with vascular pruning and distortion of branching pattern occupying all or almost all the involved parenchyma=3. The involved area was also classified as one of four grades : less than 25%=1 ; 25 - 49%=2 ; 51 - 74%=3 ; and more than 75%=4. The CT emphysema score was defined as the average of the grade of severity multiplied by the grade of involved area. Pulmonary function tests, consisting of simple spirometry and a pulmonologist's interpretation, were evaluated. We also evaluated depth and size of lesion as known predisposing factors in postbioptic pneumothorax. Statistical analysis was performed using the chi-square test, Wilcoxon ranks sum W test and the student t test. A comparison between the two groups of occurrence(with or without pneumothorax) showed the emphysema scores to be 1.69{+-}2.0 and 1.11{+-}2.9, respectively ; there was thus no significant difference between the two groups (z= - 0.048, p>0.10). Nor were differences revealed by the

  7. Thirty-six Cases of Pseudobulbar Palsy Treated by Needling with Prompt and Deep Insertion

    Institute of Scientific and Technical Information of China (English)

    Chen Hong

    2006-01-01

    @@ Pseudobulbar palsy refers to bulbar paralysis due to the upper motor neuron injury, which is one of the severe complications of cerebrovascular diseases.The author has treated 36 cases of the disease with acupuncture by a prompt and deep insertion technique, and achieved satisfactory therapeutic results. A report follows.

  8. A Case of Multiple Splenic Lymph angiomas Diagnosed by Percutaneous Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Seung Seog; Jeong, Sook Hyang; Yoon, Chang Jin; Chang, Se Jung; Choi, Joon Hyuk; Ha, Ji Su; Kim, Soon Je [KEPCO Medical foundation Hanil General Hospital, Seoul (Korea, Republic of); Lee, Hye Seung [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2007-06-15

    Lymphangioma of the spleen is an extremely rare disease in adults, and performing splenectomy has been considered necessary for its diagnosis and treatment, but the diagnosis of an isolated splenic mass lesion without performing splenectomy is a challenging problem. Herein, we report on a case of multiple splenic lymphangiomas that were found incidentally in a 56-year-old female; these lesions were diagnosed by percutaneous splenic biopsy without splenectomy. We suggest that this approach is a reasonable option for benign looking-appearing splenic tumors because splenectomy and its postsplenectomy complications can be avoided

  9. A Case of Multiple Splenic Lymph angiomas Diagnosed by Percutaneous Needle Biopsy

    International Nuclear Information System (INIS)

    Ki, Seung Seog; Jeong, Sook Hyang; Yoon, Chang Jin; Chang, Se Jung; Choi, Joon Hyuk; Ha, Ji Su; Kim, Soon Je; Lee, Hye Seung

    2007-01-01

    Lymphangioma of the spleen is an extremely rare disease in adults, and performing splenectomy has been considered necessary for its diagnosis and treatment, but the diagnosis of an isolated splenic mass lesion without performing splenectomy is a challenging problem. Herein, we report on a case of multiple splenic lymphangiomas that were found incidentally in a 56-year-old female; these lesions were diagnosed by percutaneous splenic biopsy without splenectomy. We suggest that this approach is a reasonable option for benign looking-appearing splenic tumors because splenectomy and its postsplenectomy complications can be avoided

  10. Percutaneous needle biopsy in diagnosis and identification of causative organisms in cases of suspected vertebral osteomyelitis

    International Nuclear Information System (INIS)

    Sehn, Jennifer K.; Gilula, Louis A.

    2012-01-01

    Background: Biopsy with demonstration of the infectious organism is the gold standard for diagnosing spondylodiscitis. The purpose of this study is to evaluate the positive culture rate of image-guided percutaneous biopsy in cases of radiologically suspected and unsuspected spinal osteomyelitis and to assess the role of pathology in diagnosis. Methods: With IRB approval and in compliance with HIPAA regulations, the charts of patients undergoing 323 consecutive image-guided percutaneous spinal biopsies performed by one musculoskeletal radiology department between January 2001 and March 2007 were reviewed. Image guidance was via fluoroscopy or computed tomography. Radiological and clinical suspicion, cultures, and pathology were assessed and compared to previously published reports. Results: In 92 cases radiographically and clinically consistent with infection (high probability of infection), 28 specimens yielded positive cultures (30.4%). Positive cultures resulted from 5 of 31 cases (16.1%) radiographically indeterminate for infection (intermediate probability of infection versus tumor). When radiographically not suggestive of infection (low probability of infection, i.e. suspicious for tumor), 10 of 200 cultures were positive (5.0%). From 113 cases sent to pathology with an intermediate or high suspicion for infection, 63 were histopathologically diagnosed as such (55.8%). Cultures were positive in 19 of those 63 cases (30.2%). Culture and/or pathology was positive in 73 (64.6%) of the 113 cases. There were no significant differences in rates of positive culture or pathology by vertebral region (p = 0.51, p = 0.81). The most frequently identified organisms were Staphylococcus aureus (13) and coagulase negative staphylococci (13). Conclusions: Our results suggest that the positive culture rate of percutaneous spinal biopsy specimens is 30.4% with radiographically high probability for infection, which is lower than previously published. Infection may also be present

  11. ''Push-pull'' gastrostomy: a new technique for percutaneous gastrostomy tube insertion in the neonate and young infant

    International Nuclear Information System (INIS)

    Cahill, A.M.; Kaye, R.D.; Fitz, C.R.; Towbin, R.B.

    2001-01-01

    Objective. To evaluate a newly developed method combining antegrade and retrograde techniques for percutaneous gastrostomy tube (PGT) insertion in the neonate and young infant. Materials and methods. From January 1994 to December 2000, 85 children (47 male, 38 female), mean age 4.5 months (range 0.44-9.13 months) underwent PGT insertion using the ''push-pull'' technique. With the addition, 57 children had a jejunostomy tube placed as well at or within 24 h of the PGT procedure. The mean weight was 3.74 kg, range 1.5-7.0 kg. The indications for the procedure included failure to thrive in 40 patients (25 %), static encephalopathy in 21 (25 %), neurological/congenital abnormalities in 12 (14 %), aspiration in 7 (8 %), and cardiac problems in 5 (6 %). Results. Eighty-five PGTs were successfully inserted in 85 children. One procedure was initially unsuccessful due to failed conscious sedation and was completed under general anesthesia. Four of 85 patients initially had attempted antegrade placement that failed, and the procedure was successfully completed using the ''push-pull'' method. One major complication occurred: a gastrocolic fistula at day 5 post-procedure, which was surgically repaired without sequelae. Tube-related problems included; tube dislodgement (n = 1) and procedure-related stomal infection (n = 3). Conclusion. The ''push-pull'' gastrostomy technique is a safe, effective method of percutaneous gastrostomy tube placement in neonates. It facilitates successful placement of the PGT in patients in whom the classic antegrade method is not possible. It has become the procedure of choice in this group. (orig.)

  12. Ultrasound-guided percutaneous needle electrolysis in chronic lateral epicondylitis: short-term and long-term results

    Science.gov (United States)

    Valera-Garrido, Fermín; Minaya-Muñoz, Francisco; Medina-Mirapeix, Francesc

    2014-01-01

    Background Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach which consists of the application of a galvanic current through an acupuncture needle. Objective To evaluate the clinical and ultrasonographic effectiveness of a multimodal programme (PNE, eccentric exercise (EccEx) and stretching) in the short term for patients with chronic lateral epicondylitis, and to determine whether the clinical outcomes achieved decline over time. Methods A one-way repeated measures study was performed in a clinical setting in 36 patients presenting with lateral epicondylitis. The patients received one session of US-guided PNE per week over 4–6 weeks, associated with a home programme of EccEx and stretching. The main outcome measures were severity of pain, disability (Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), structural tendon changes (US), hypervascularity and patients’ perceptions of overall outcome. Measurements at 6, 26 and 52 weeks follow-up included recurrence rates (increase in severity of pain or disability compared with discharge), perception of overall outcome and success rates. Results All outcome measures registered significant improvements between pre-intervention and discharge. Most patients (n=30, 83.3%) rated the overall outcome as ‘successful’ at 6 weeks. The ultrasonographic findings showed that the hypoechoic regions and hypervascularity of the extensor carpi radialis brevis changed significantly. At 26 and 52 weeks, all participants (n=32) perceived a ‘successful’ outcome. Recurrence rates were null after discharge and at follow-up at 6, 26 and 52 weeks. Conclusions Symptoms and degenerative structural changes of chronic lateral epicondylitis are reduced after US-guided PNE associated with EccEx and stretching, with encouragingly low recurrences in the mid to long term. Trial registration number ClinicalTrials.gov identifier: NCT02085928. PMID:25122629

  13. Percutaneous sharp recanalization of a membranous IVC occlusion with an occlusion balloon as a needle target

    Directory of Open Access Journals (Sweden)

    Michael D. Rivers-Bowerman, MD, MSc, FRCPC

    2017-09-01

    Full Text Available A 50-year-old male with right upper quadrant symptoms and hepatic dysfunction was found to have multiple dilated hepatic veins (HVs with intrahepatic collateralization and membranous occlusion of the intrahepatic inferior vena cava (IVC consistent with primary Budd–Chiari syndrome. Venacavograms depicted drainage of the intrahepatic collaterals through a left-sided HV entering the IVC above the level of the occlusion. Sharp recanalization of the membranous IVC occlusion was performed with an occlusion balloon as a needle target under echocardiographic monitoring followed by balloon angioplasty with restoration of IVC patency. Clinical, laboratory, and venographic procedural success has been demonstrated to 9 months with minimal residual stenosis.

  14. Left Atrial Decompression by Percutaneous Left Atrial Venting Cannula Insertion during Venoarterial Extracorporeal Membrane Oxygenation Support

    Directory of Open Access Journals (Sweden)

    Ha Eun Kim

    2016-06-01

    Full Text Available Patients with venoarterial extracorporeal membrane oxygenation (ECMO frequently suffer from pulmonary edema due to left ventricular dysfunction that accompanies left heart dilatation, which is caused by left atrial hypertension. The problem can be resolved by left atrium (LA decompression. We performed a successful percutaneous LA decompression with an atrial septostomy and placement of an LA venting cannula in a 38-month-old child treated with venoarterial ECMO for acute myocarditis.

  15. A Fabry-Perot Interferometry Based MRI-Compatible Miniature Uniaxial Force Sensor for Percutaneous Needle Placement

    Science.gov (United States)

    Shang, Weijian; Su, Hao; Li, Gang; Furlong, Cosme; Fischer, Gregory S.

    2014-01-01

    Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scanner. The opto-electronic sensing system design was minimized to fit inside an MRI-compatible robot controller enclosure. A flexure mechanism was designed that integrates the FPI sensor fiber for measuring needle insertion force, and finite element analysis was performed for optimizing the correct force-deformation relationship. The compact, low-cost FPI sensing system was integrated into the robot and calibration was conducted. The root mean square (RMS) error of the calibration among the range of 0–10 Newton was 0.318 Newton comparing to the theoretical model which has been proven sufficient for robot control and teleoperation. PMID:25126153

  16. Treatment of the calcific tendinopathy of the rotator cuff by ultrasound-guided percutaneous needle lavage. Two years prospective study

    Science.gov (United States)

    Castillo-González, Federico Del; Ramos-Álvarez, Juan José; Rodríguez-Fabián, Guillermo; González-Pérez, José; Calderón-Montero, Javier

    2014-01-01

    Summary Background: to evaluate the short and long term effectiveness of ultrasonography (US)-guided percutaneous needle lavage in calcific tendinopathy of the rotator cuff. To study the evolution of the size of calcifications and pain in the two years after treatment. Methods: study design: A 2 year longitudinal prospective study is carried out after applying the UGPL technique on a number of patients diagnosed with calcific tendinitis of the rotator cuff. Clinical, ultrasound and radiology follow-up controls were performed, 3 months, 6 months, one year and two years after the treatment. The Visual Analog Scale (VAS) was used to assess the pain. The degree and point of pain is selected on a 10 cm line, arranged horizontally or vertically. The “0” represents no pain and “10” represents worst pain. The population studied was made up of 121 patients that required our service as a result of suffering from a painful shoulder. Results: the pain (VAS) and the size of the calcification significantly decreased with the application of the technique (ptendinitis of the shoulder. The intervention is simple, cost-effective, does not require hospitalization, involves no complications, rehabilitation treatment is not required and it shows very few side effects without sequelae, significantly reducing the size of the calcification and pain in the majority of patients. PMID:25332939

  17. Diagnostic accuracy of percutaneous cytodiagnosis of hepatic masses, by ultrasound guided fine needle aspiration cytology

    International Nuclear Information System (INIS)

    Asghar, F.; Riaz, S.

    2010-01-01

    Objective: To evaluate the diagnostic accuracy, usefulness and limitations of ultrasound guided FNAC of hepatic masses. Design: Cross - sectional analytical (comparative study). Place and Duration: Department of histopathology, Sheikh Zayed Hospital, Lahore. Study period 1 year. Material and Methods: A total of 32 patients with solitary or multiple hepatic masses underwent FNAC from March 1999 to March 2000. Adequate aspirates were obtained in all these cases. Smears were stained with May-Grunwald Giemsa, Haematoxylin and Eosin and Papanicolaou stain. Needle biopsies from the same cases were also obtained and processed. These were stained with routine Haematoxylin and Eosin staining. The blood clots obtained during FNAC were fixed in 10% neu-tral buffered formalin. The histopathology of these blood clots was used for cases whose needle core biopsy was not available. The screened FNAC smears were divided into 3 categories i.e., benign (group - I), malignant (group - II), non-neoplastic / inflammatory lesions (including cysts and abscesses) (group - III). Results: Out of 32 cases, 6 were categorized as benign, 18 as malignant, and 8 as non-neoplastic inflammatory lesions. Three false negative diagnoses, including 1 for malignant tumour and 2 for benign tumours was obtained. There was 1 false positive diagnosis for malignancy. FNAC - histological correlation showed a 94.2% sensitivity and 92.3% diagnostic accuracy for malignant tumours, while benign tumours posed maximum diagnostic problems, giving a 66.67% sensitivity and 85.7% diagnostic accuracy. FNAC picked up correctly all the non-neoplastic lesions giving a 100% sensitivity and diagnostic accuracy. Conclusion: Majority of the malignant tumours can be categorized on FNAC, with a high degree of accuracy, while benign tumours should be subjected to biopsy, as there is a relatively greater possibility of false negative diagnosis. (author)

  18. Precision insertion of percutaneous sacroiliac screws using a novel augmented reality-based navigation system: a pilot study.

    Science.gov (United States)

    Wang, Huixiang; Wang, Fang; Leong, Anthony Peng Yew; Xu, Lu; Chen, Xiaojun; Wang, Qiugen

    2016-09-01

    Augmented reality (AR) enables superimposition of virtual images onto the real world. The aim of this study is to present a novel AR-based navigation system for sacroiliac screw insertion and to evaluate its feasibility and accuracy in cadaveric experiments. Six cadavers with intact pelvises were employed in our study. They were CT scanned and the pelvis and vessels were segmented into 3D models. The ideal trajectory of the sacroiliac screw was planned and represented visually as a cylinder. For the intervention, the head mounted display created a real-time AR environment by superimposing the virtual 3D models onto the surgeon's field of view. The screws were drilled into the pelvis as guided by the trajectory represented by the cylinder. Following the intervention, a repeat CT scan was performed to evaluate the accuracy of the system, by assessing the screw positions and the deviations between the planned trajectories and inserted screws. Post-operative CT images showed that all 12 screws were correctly placed with no perforation. The mean deviation between the planned trajectories and the inserted screws was 2.7 ± 1.2 mm at the bony entry point, 3.7 ± 1.1 mm at the screw tip, and the mean angular deviation between the two trajectories was 2.9° ± 1.1°. The mean deviation at the nerve root tunnels region on the sagittal plane was 3.6 ± 1.0 mm. This study suggests an intuitive approach for guiding screw placement by way of AR-based navigation. This approach was feasible and accurate. It may serve as a valuable tool for assisting percutaneous sacroiliac screw insertion in live surgery.

  19. The results of the percutaneous endoscopic gastrostomy insertion: Analysis of 113 cases

    Directory of Open Access Journals (Sweden)

    Nazım Ekin

    2015-09-01

    Full Text Available Objective: In this study, we aimed to evaluate the results and experiences of the patients who received percutaneous endoscopic gastrostomy (PEG. Methods: A total of 113 patients who admitted to the Dicle University Medical Faculty , Department of Gastroenterology between January 2012 and December 2014 and in whom received PEG was performed. The patients were assessed in terms of indications, complications and results. Results: Among these patients, 70 (61.9% were male and 40 (38.1% were female. Though 8 (7% patients had head, neck and esophageal cancer; 105 (93% patients had primer or seconder neurological disorders. After the PEG, any serious complication was seen in patients. Wound infections were encountered in five patients (4.4% and the rate of minor complications was found to be 9.7%. The risk of complications was higher in patients over sixty years and men (p values of 0.049 and 0.022. Conclusion: Percutaneous endoscopic gastrostomy, a simple and safe method of enteral nutrition with a low complication rate, should be the first choice when extended period enteral nutrition is required. There is increased risk of complications in elderly males.

  20. Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Braak, Sicco J., E-mail: sjbraak@gmail.com [St. Antonius Hospital, Department of Radiology (Netherlands); Herder, Gerarda J. M., E-mail: j.herder@antoniusziekenhuis.nl [St. Antonius Hospital, Department of Pulmonology (Netherlands); Heesewijk, Johannes P. M. van, E-mail: j.heesewijk@antoniusziekenhuis.nl; Strijen, Marco J. L. van, E-mail: m.van.strijen@antoniusziekenhuis.nl [St. Antonius Hospital, Department of Radiology (Netherlands)

    2012-12-15

    Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24-85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose-area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results: Mean lesion diameter was 32.5 (range 3.0-93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1-7). Mean fluoroscopy time was 161 (range 104-551) s, room time was 34 (range 15-79) min, mean DAP value was 25.9 (range 3.9-80.5) Gy{center_dot}cm{sup -2}, and interventional time was 18 (range 5-65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86-96), 100% (95% CI 82-100), 100% (95% CI 96-100), 66.7% (95% CI 55-83), and 91.7% (95% CI 86-96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion: CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.

  1. Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

    International Nuclear Information System (INIS)

    Braak, Sicco J.; Herder, Gerarda J. M.; Heesewijk, Johannes P. M. van; Strijen, Marco J. L. van

    2012-01-01

    Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24–85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose–area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results: Mean lesion diameter was 32.5 (range 3.0–93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1–7). Mean fluoroscopy time was 161 (range 104–551) s, room time was 34 (range 15–79) min, mean DAP value was 25.9 (range 3.9–80.5) Gy·cm −2 , and interventional time was 18 (range 5–65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86–96), 100% (95% CI 82–100), 100% (95% CI 96–100), 66.7% (95% CI 55–83), and 91.7% (95% CI 86–96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion: CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.

  2. Real-time fluoroscopic needle guidance in the interventional radiology suite using navigational software for percutaneous bone biopsies in children

    Energy Technology Data Exchange (ETDEWEB)

    Shellikeri, Sphoorti; Srinivasan, Abhay; Krishnamurthy, Ganesh; Vatsky, Seth; Zhu, Xiaowei; Keller, Marc S.; Cahill, Anne Marie [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Setser, Randolph M. [Siemens Medical Solutions USA, Inc., Hoffman Estates, IL (United States); Hwang, Tiffany J. [University of Southern California, Keck School of Medicine, Los Angeles, CA (United States); Girard, Erin [Siemens Medical Solutions USA, Inc., Princeton, NJ (United States)

    2017-07-15

    Navigational software provides real-time fluoroscopic needle guidance for percutaneous procedures in the Interventional Radiology (IR) suite. We describe our experience with navigational software for pediatric percutaneous bone biopsies in the IR suite and compare technical success, diagnostic accuracy, radiation dose and procedure time with that of CT-guided biopsies. Pediatric bone biopsies performed using navigational software (Syngo iGuide, Siemens Healthcare) from 2011 to 2016 were prospectively included and anatomically matched CT-guided bone biopsies from 2008 to 2016 were retrospectively reviewed with institutional review board approval. C-arm CT protocols used for navigational software-assisted cases included institution-developed low-dose (0.1/0.17 μGy/projection), regular-dose (0.36 μGy/projection), or a combination of low-dose/regular-dose protocols. Estimated effective radiation dose and procedure times were compared between software-assisted and CT-guided biopsies. Twenty-six patients (15 male; mean age: 10 years) underwent software-assisted biopsies (15 pelvic, 7 lumbar and 4 lower extremity) and 33 patients (13 male; mean age: 9 years) underwent CT-guided biopsies (22 pelvic, 7 lumbar and 4 lower extremity). Both modality biopsies resulted in a 100% technical success rate. Twenty-five of 26 (96%) software-assisted and 29/33 (88%) CT-guided biopsies were diagnostic. Overall, the effective radiation dose was significantly lower in software-assisted than CT-guided cases (3.0±3.4 vs. 6.6±7.7 mSv, P=0.02). The effective dose difference was most dramatic in software-assisted cases using low-dose C-arm CT (1.2±1.8 vs. 6.6±7.7 mSv, P=0.001) or combined low-dose/regular-dose C-arm CT (1.9±2.4 vs. 6.6±7.7 mSv, P=0.04), whereas effective dose was comparable in software-assisted cases using regular-dose C-arm CT (6.0±3.5 vs. 6.6±7.7 mSv, P=0.7). Mean procedure time was significantly lower for software-assisted cases (91±54 vs. 141±68 min, P=0

  3. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  4. Are percutaneous transgastric biopsies using 14-,16- and 18-G Tru-Cut needles safe? An experimental study in the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Akan, H.; Incesu, L.; Gunes, M. [Ondokuz Mayis University Medical School, Samsun (Turkey). Department of Radiology; Ozen, N.; Gumus, S. [Ondokuz Mayis University Medical School, Samsun (Turkey). Department of Surgery

    1998-05-01

    We evaluated perforation, peritonitis and bleeding after 14-, 16-, 18-G Tru-Cut needles were passed through the stomach in an animal model. Insertions were performed on seven anesthetized rabbits with 18-,16-and 14-G needles simulating the clinical technique. Diluted contrast medium with methylene blue (60mL) was administered through a nasogastric tube after the biopsy. Computed tomography (CT) scanning of the upper abdomen was performed 10 minutes after the insertion for leakage. The abdominal contents were inspected by laparotomy. There was no contrast medium leakage outside the gastrointestinal tract on CT images. Neither methylene blue nor other stomach content leakage was identified by laparotomy, even with manual squeezing. A tiny spot of blood was observed on the serosal surface of the stomach with the 18-G needle passes (five cases), whereas a relatively large haematoma was present with 14-G needle (four cases). Six of the rabbits survived and one died due to an inadvertant aortic injury. The results of the study show that transgastric route with an 1 8-G cutting needle can be used without fear of peritonitis and bleeding. Copyright (1998) Blackwell Science Pty Ltd 19 refs., 1 tab., 1 fig.

  5. Are percutaneous transgastric biopsies using 14-,16- and 18-G Tru-Cut needles safe? An experimental study in the rabbit

    International Nuclear Information System (INIS)

    Akan, H.; Incesu, L.; Gunes, M.; Ozen, N.; Gumus, S.

    1998-01-01

    We evaluated perforation, peritonitis and bleeding after 14-, 16-, 18-G Tru-Cut needles were passed through the stomach in an animal model. Insertions were performed on seven anesthetized rabbits with 18-,16-and 14-G needles simulating the clinical technique. Diluted contrast medium with methylene blue (60mL) was administered through a nasogastric tube after the biopsy. Computed tomography (CT) scanning of the upper abdomen was performed 10 minutes after the insertion for leakage. The abdominal contents were inspected by laparotomy. There was no contrast medium leakage outside the gastrointestinal tract on CT images. Neither methylene blue nor other stomach content leakage was identified by laparotomy, even with manual squeezing. A tiny spot of blood was observed on the serosal surface of the stomach with the 18-G needle passes (five cases), whereas a relatively large haematoma was present with 14-G needle (four cases). Six of the rabbits survived and one died due to an inadvertant aortic injury. The results of the study show that transgastric route with an 1 8-G cutting needle can be used without fear of peritonitis and bleeding. Copyright (1998) Blackwell Science Pty Ltd

  6. Percutaneous intervention in obstructive

    International Nuclear Information System (INIS)

    Souftas, V.

    2012-01-01

    , performed by the urologist. Before performing a lithotripsy, percutaneous access of the renal collecting system is necessary. Percutaneous ureteral lithotripsy is indicated for management of large renal stones. The kidneys are accessed either using ultrasound, if there is a dilated collecting system, or fluoroscopy, if there is a radiopaque stone. The most ideal access is a calyx that bears the stone. Once access is obtained an angled glide wire is used to cross the obstructing stone and gain access to the ureter. Two wires can then be advanced to the bladder to provide a 'working wire' and a 'safety wire'. Success of lithotripsy is 98-99% for targeted renal stones and 88-89% for ureteral stones. If using only fluoroscopy, a sheathed needle may be used to access the bladder under fluoroscopy. Once urine is aspirated through the sheathed needle, a 3Jwire is inserted into the bladder under fluoroscopy. Using an angled guiding catheter, the 3J-wire is exchanged for an Amplatz and serial dilatation of the tract is performed over the Amplatz. Finally, an 8-F to 12-F suprapubic Foley catheter is inserted over the Amplatz wire into the bladder. Success rate for suprapubic tube insertion has been reported to approach 100% and is comparable to surgical insertion. Complications include bleeding, infection, and bladder or bowel perforation. Perinephric/retroperitoneal urinomas/abscesses drainages are usually due to ureteral obstruction/ trauma from calculi and rupture of the collecting system or to iatrogenic trauma. Most often they are performed under CT guidance, with success rates 100% and very low complication rates. Pigtail drainage catheters 8-F (up to 14-F for abscesses) are used. Sometimes these procedures have to be combined with percutaneous nephrostomy and percutaneous or antegrade ureteral stent placement.

  7. Comparison of conventional straight and swan-neck straight catheters inserted by percutaneous method for continuous ambulatory peritoneal dialysis: a single-center study.

    Science.gov (United States)

    Singh, Shivendra; Prakash, Jai; Singh, R G; Dole, P K; Pant, Pragya

    2015-10-01

    To evaluate the incidence of mechanical and infectious complications of conventional straight catheter (SC) versus swan-neck straight catheter (SNSC) implanted by percutaneous method. We retrospectively analyzed 45 catheter insertions being done by percutaneous method from January 1, 2011, to May 31, 2014. SC was inserted in 24 patients, and SNSC was inserted in 21 patients. Baseline characteristics for the two groups were similar with respect to age, sex and diabetic nephropathy as the cause for end-stage renal disease. Incidence of mechanical and infectious complications in SNSC group was found to be low as compared to the SC group and was statistically significant (1 in 11.6 patient months vs. 1 in 14.4 patient months, p = 0.02). Catheter migration was found to be the most common mechanical complication (20 %), and peritonitis was found to be the most common infectious complication in conventional SC group (27 episodes in 420 patient months vs. 11 episodes in 333 patient months, p = 0.03). The incidence of exit site and tunnel infection rates revealed no difference between the groups. SNSC insertion by percutaneous method is associated with low mechanical and infectious complications.

  8. A navigation system for percutaneous needle interventions based on PET/CT images: design, workflow and error analysis of soft tissue and bone punctures.

    Science.gov (United States)

    Oliveira-Santos, Thiago; Klaeser, Bernd; Weitzel, Thilo; Krause, Thomas; Nolte, Lutz-Peter; Peterhans, Matthias; Weber, Stefan

    2011-01-01

    Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well

  9. Preoperative US-guided hook-needle insertion in recurrent lymph nodes of papillary thyroid cancer: A help for the surgeon

    International Nuclear Information System (INIS)

    Duprez, Raphaelle; Lebas, Patrick; Marc, Olivier Saint; Mongeois, Elise; Emy, Philippe; Michenet, Patrick

    2010-01-01

    Objective: The objective of this study is to investigate whether preoperative ultrasound guided insertion of a hook-needle is useful in reoperations for cervical recurrent lymph node metastases of papillary thyroid cancer. Patients and methods: 8 patients with operated papillary thyroid cancer were included in this study. They all had suspicious nonpalpable cervical lymph nodes discovered during follow-up. These lymph nodes were identified by ultrasound imaging and their metastatic nature was confirmed by fine needle aspiration cytology and measurement of in situ thyroglobulin. In all cases, surgical excision of these lymph nodes was decided. All 8 patients had a hook-needle inserted in the suspicious lymph node(s) preoperatively and under ultrasound guidance. Results and conclusion: In all 8 patients, the suspicious lymph nodes were removed and their metastatic nature was confirmed by the final pathological examination. This localization technique is very helpful for the surgeon during the excision of small and nonpalpable lymph nodes, especially in previously operated area.

  10. Arctigenin Treatment Protects against Brain Damage through an Anti-Inflammatory and Anti-Apoptotic Mechanism after Needle Insertion

    Science.gov (United States)

    Song, Jie; Li, Na; Xia, Yang; Gao, Zhong; Zou, Sa-feng; Kong, Liang; Yao, Ying-Jia; Jiao, Ya-Nan; Yan, Yu-Hui; Li, Shao-Heng; Tao, Zhen-Yu; Lian, Guan; Yang, Jing-Xian; Kang, Ting-Guo

    2016-01-01

    Convection enhanced delivery (CED) infuses drugs directly into brain tissue. Needle insertion is required and results in a stab wound injury (SWI). Subsequent secondary injury involves the release of inflammatory and apoptotic cytokines, which have dramatic consequences on the integrity of damaged tissue, leading to the evolution of a pericontusional-damaged area minutes to days after in the initial injury. The present study investigated the capacity for arctigenin (ARC) to prevent secondary brain injury and the determination of the underlying mechanism of action in a mouse model of SWI that mimics the process of CED. After CED, mice received a gavage of ARC from 30 min to 14 days. Neurological severity scores (NSS) and wound closure degree were assessed after the injury. Histological analysis and immunocytochemistry were used to evaluated the extent of brain damage and neuroinflammation. Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) was used to detect universal apoptosis. Enzyme-linked immunosorbent assays (ELISA) was used to test the inflammatory cytokines (tumor necrosis factor (TNF)-α, interleukin (IL)-6 and IL-10) and lactate dehydrogenase (LDH) content. Gene levels of inflammation (TNF-α, IL-6, and IL-10) and apoptosis (Caspase-3, Bax and Bcl-2) were detected by reverse transcription-polymerase chain reaction (RT-PCR). Using these, we analyzed ARC’s efficacy and mechanism of action. Results: ARC treatment improved neurological function by reducing brain water content and hematoma and accelerating wound closure relative to untreated mice. ARC treatment reduced the levels of TNF-α and IL-6 and the number of allograft inflammatory factor (IBA)- and myeloperoxidase (MPO)-positive cells and increased the levels of IL-10. ARC-treated mice had fewer TUNEL+ apoptotic neurons and activated caspase-3-positive neurons surrounding the lesion than controls, indicating increased neuronal survival. Conclusions: ARC treatment confers

  11. Veress needle insertion into the left hypochondrium for creation of pneumoperitoneum: diagnostic value of tests to determine the position of the needle in unselected patients.

    Science.gov (United States)

    Becker, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; de Azevedo, Otávio Cansanção; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes

    2011-01-01

    To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test--AT; resistance to infusion--Pres; recovery of the infused fluid--Prec, dripping test--DT, and test of initial intraperitoneal pressure--IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. There were 13 failures. AT had E = 100% and NPV 100%. Pres had S = 100%, E = 0; PPV = 85.71%; NPV does not apply. Prec: S = 100%, E = 53.84%, PPV = 92.85%, NPV = 100%. DT: S = 100%, E = 61.53%, PPV = 93.97% NPV 100%. In IIPP, S, E, PPV and NPV were 100%. The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.

  12. Ultrasound-guided percutaneous treatment of hepatocellular carcinoma by radiofrequency hyperthermia with a 'cooled-tip needle'. A preliminary clinical experience.

    Science.gov (United States)

    Francica, G; Marone, G

    1999-05-01

    three recorded deaths, two were due to intrahepatic tumor diffusion. In our experience radiofrequency hyperthermia with the cooled-tip needle afforded an effective and safe percutaneous ablative method for HCC in cirrhosis and shortened treatment time.

  13. Inferior vena cava filter insertion through the popliteal vein: enabling the percutaneous endovenous intervention of deep vein thrombosis with a single venous access approach in a single session

    Science.gov (United States)

    Kim, Hyoung Ook; Kim, Jae Kyu; Park, Jin Gyoon; Yim, Nam Yeol; Kang, Yang Jun; Jung, Hye Doo

    2016-01-01

    PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis. METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period. Patient medical records were reviewed for the location of the deep vein thrombosis, result of filter removal, and total number of endovascular procedures needed for filter insertion and recanalization of the lower extremity venous system. Follow-up lower extremity computed tomography (CT) venography was also reviewed in each patient to assess the degree of filter tilt in the IVC. RESULTS All patients had extensive lower extremity deep vein thrombosis involving the iliac vein and/or femoral vein. Seventeen patients showed deep vein thrombosis of the calf veins. In all patients, IVC filter insertion and the recanalization procedure were performed during a single procedure through the single popliteal vein access site. In the 17 patients undergoing follow-up CT, the mean tilt angle of the filter was 7.14°±4.48° in the coronal plane and 8.77°±5.49° in the sagittal plane. Filter retrieval was successful in 16 of 17 patients (94.1%) in whom filter retrieval was attempted. CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention. PMID:27559713

  14. [Percutaneous tracheotomy].

    Science.gov (United States)

    Paleczny, J; Maciejewski, D; Łoniewska-Paleczny, E; Sawczuk, M; Kaczur, A

    2000-01-01

    The purpose of this study was to compare on the basis of up to date papers currently applied methods of the percutaneous tracheostomy (PT). There are four main PT methods by: Ciaglia, Schachner, Griggs and Fantoni. In these methods a wire is introduced into the trachea serving as a guide for special forceps or series of dilatators of increasing diameter to dilate the wall and allow cannulation of the trachea. In the literature authors found a low incidence of complications after PT. Acute complications were documented in 6-18% and late complications in 1-3% of the patients. Follow-up showed no late obstructive complications at the level of stomia and very low (0.3-0.36%) mortality risk. Translaryngeal tracheostomy (TLT) by Fantoni ensures minimal risk of complications and tissue trauma. In the TLT method through a needle inserted in to the trachea a guide wire is retrogradely pushed out of the mouth and attached to special flexible tracheostomy tube by flexible plastic cone with pointed metal tip. This device is then pulled back through larynx and outwards across the trachea and neck wall by traction on the wire. TLT can also be used in infants and children and in difficult patients in whom other techniques are riskier Review of the literature suggests that the PT can be safe and also cost-effective for properly selected patients in intensive care and other hospital units.

  15. Clinical background and its relation to results of percutaneous needle biopsy of suspected bone metastasis under guidance with CT fluoroscopy

    International Nuclear Information System (INIS)

    Aoki, Jun; Koyama, Yoshinori; Morita, Hideo; Takahashi, Ayako; Nakajima, Takahito; Yagi, Akiko; Arai, Kiyokazu; Shinozaki, Tetsuya; Watanabe, Hideomi

    2005-01-01

    The purpose of this study was to investigate the clinical background of needle biopsy of suspected bone metastasis under guidance with CT fluoroscopy. During a 3-year period (from April 2000 to March 2003), 103 needle biopsies on 101 lesions of 90 patients were performed for pathological evaluation of suspected bone metastasis. The clinical course of these patients prior to biopsy and its relation to the biopsy results were retrospectively reviewed. Sixty-two patients (69% of total cases) were referred for biopsy from orthopedic surgeons, and 51 of these patients consulted orthopedic surgeons on the initial presentation. Malignancy was pathologically proved in 47 (76%) of the 62 orthopedic patients, and in 19 (68%) of the 28 patients referred from other clinicians. Thirteen (21%) of the orthopedic patients had a history of malignancy, while 22 (78%) of the non-orthopedic patients were cancer patients. Metastasis was pathologically proved in 23 (66%) of the 35 patients with a history of malignancy, while malignancy was pathologically proved in 43 (78%) of the 55 patients without known malignancy. Diagnostic accuracy of the needle bone biopsy was 96%, and its complication rate was 0.7%. In the era of CT fluoroscopy, needle biopsy for suspected bone metastasis was most frequently requested for the patients who consulted orthopedic surgeons for the occurrence of local bone pain as the initial symptom of unknown malignancy. Frequency of malignancy proved by the biopsy in those patients was as high as that in the cancer patients referred from other clinicians. (author)

  16. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    International Nuclear Information System (INIS)

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L.

    2010-01-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  17. A Fabry-Perot Interferometry Based MRI-Compatible Miniature Uniaxial Force Sensor for Percutaneous Needle Placement

    OpenAIRE

    Shang, Weijian; Su, Hao; Li, Gang; Furlong, Cosme; Fischer, Gregory S.

    2013-01-01

    Robot-assisted surgical procedures, taking advantage of the high soft tissue contrast and real-time imaging of magnetic resonance imaging (MRI), are developing rapidly. However, it is crucial to maintain tactile force feedback in MRI-guided needle-based procedures. This paper presents a Fabry-Perot interference (FPI) based system of an MRI-compatible fiber optic sensor which has been integrated into a piezoelectrically actuated robot for prostate cancer biopsy and brachytherapy in 3T MRI scan...

  18. Mechanics of needle-tissue interaction

    NARCIS (Netherlands)

    Roesthuis, Roy; van Veen, Youri; Jahya, Alex; Misra, Sarthak

    2011-01-01

    When a needle is inserted into soft tissue, interac- tion forces are developed at the needle tip and along the needle shaft. The needle tip force is due to cutting of the tissue, and the force along the needle shaft is due to friction between needle and tissue. In this study, the friction force is

  19. Laparoscopic and Percutaneous Core Needle Biopsy Plays a Central Role for the Diagnosis of Autoimmune Pancreatitis in a Single-Center Study from Denmark

    DEFF Research Database (Denmark)

    Detlefsen, Sönke; Mortensen, Michael Bau; Kjærulf Pless, Torsten

    2015-01-01

    organ involvement was observed in 40% of type 1 and 13% of type 2, but inflammatory bowel disease only in type 2 (P = 0.001). One patient had IgG4-related chronic perisplenitis as a hitherto undescribed manifestation of IgG4-related disease. Nineteen (91%) of 21 biopsied patients had diagnostic CNB...... Hospital from 2007 to 2013 were included (n = 30; mean follow-up, 26.2 months). Data from laparoscopic or percutaneous ultrasound-guided core needle biopsy (CNB), resection specimens, endoscopic ultrasound (EUS), EUS-guided CNB, computed tomography, serum immunoglobulin G4 (IgG4), and pancreatography were...... retrospectively analyzed according to ICDC. RESULTS: Twenty patients were diagnosed with type 1, 8 with type 2, and 2 with not otherwise specified AIP. Twenty-eight patients (93%) could correctly be classified when ICDC were retrospectively applied. Serum IgG4 was elevated in 44% of type 1 and 0% of type 2. Other...

  20. A Simplified Technique of Percutaneous Hepatic Artery Port-Catheter Insertion for the Treatment of Advanced Hepatocellular Carcinoma with Portal Vein Invasion

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Ah Hyun; Lee, Do Yun; Lee, Kwang Hun; Won, Jong Yun [Yonsei University College of Medicine, Severance Hospital, Seoul (Korea, Republic of); Kim, Kyung Ah [Inje University Ilsan Paik Hospital, Ilsan (Korea, Republic of)

    2010-12-15

    We assessed the outcomes of a simplified technique for the percutaneous placement of a hepatic artery port-catheter system for chemotherapy infusion in advanced hepatocellular carcinoma with portal vein invasion. From February 2003 to February 2008, percutaneous hepatic artery port-catheter insertion was performed in 122 patients who had hepatocellular carcinoma with portal vein invasion. The arterial access route was the common femoral artery. The tip of the catheter was wedged into the right gastroepiploic artery without an additional fixation device. A side hole was positioned at the distal common hepatic artery to allow the delivery of chemotherapeutic agents into the hepatic arteries. Coil embolization was performed only to redistribute to the hepatic arteries or to prevent the inadvertent delivery of chemotherapeutic agents into extrahepatic arteries. The port chamber was created at either the supra-inguinal or infra-inguinal region. Technical success was achieved in all patients. Proper positioning of the side hole was checked before each scheduled chemotherapy session by port angiography. Catheter-related complications occurred in 19 patients (16%). Revision was achieved in 15 of 18 patients (83%). This simplified method demonstrates excellent technical feasibility, an acceptable range of complications, and is hence recommended for the management of advanced hepatocellular carcinoma with portal vein thrombosis

  1. A Randomised Clinical Trial to Compare Coaxial and Noncoaxial Techniques in Percutaneous Core Needle Biopsy of Renal Parenchyma

    International Nuclear Information System (INIS)

    Babaei Jandaghi, Ali; Lebady, Mohammadkazem; Zamani, Athar-Alsadat; Heidarzadeh, Abtin; Monfared, Ali; Pourghorban, Ramin

    2017-01-01

    PurposeTo compare the coaxial and noncoaxial techniques of renal parenchymal core needle biopsy.Materials and MethodsThis is an institutional review board-approved randomised controlled trial comparing 83 patients (male, n = 49) who underwent renal parenchymal core biopsy with coaxial method and 83 patients (male, n = 40) with noncoaxial method. The rate of complications, the number of glomerular profiles, and the procedural time were evaluated in a comparison of the two methods. Correlation between the presence of renal parenchymal disease and the rate of complication was also evaluated.ResultsThe procedural time was significantly shorter in the coaxial technique (coaxial group, 5 ± 1 min; noncoaxial group, 14 ± 2 min; p < 0.001). The rates of complications for the coaxial method was significantly lower than the noncoaxial method (coaxial group, 10.8 %; noncoaxial group, 24.1 %; p = 0.025). There was no significant correlation between gender and the rate of complication. The number of glomerular profiles was significantly higher in patents who underwent renal biopsy with the coaxial method (coaxial group, 18.2 ± 9.1; noncoaxial group, 8.6 ± 5.5; p < 0.001). In the whole study population, the rate of complications was significantly higher in patients with a pathologic renal parenchyma compared to those with a normal parenchyma (19/71 vs. 10/95; p = 0.006).ConclusionsRenal parenchymal biopsy using a coaxial needle is a faster and safer method with a lower rate of complications.

  2. A Randomised Clinical Trial to Compare Coaxial and Noncoaxial Techniques in Percutaneous Core Needle Biopsy of Renal Parenchyma

    Energy Technology Data Exchange (ETDEWEB)

    Babaei Jandaghi, Ali [Guilan University of Medical Sciences, Department of Radiology, Poursina Hospital (Iran, Islamic Republic of); Lebady, Mohammadkazem; Zamani, Athar-Alsadat [Guilan University of Medical Sciences, Urology Research Center, Razi Hospital (Iran, Islamic Republic of); Heidarzadeh, Abtin [Guilan University of Medical Sciences, Department of Community Medicine (Iran, Islamic Republic of); Monfared, Ali [Guilan University of Medical Sciences, Urology Research Center, Razi Hospital (Iran, Islamic Republic of); Pourghorban, Ramin, E-mail: ramin-p2005@yahoo.com [Tehran University of Medical Sciences, Department of Radiology, Imam Khomeini Hospital Complex (Iran, Islamic Republic of)

    2017-01-15

    PurposeTo compare the coaxial and noncoaxial techniques of renal parenchymal core needle biopsy.Materials and MethodsThis is an institutional review board-approved randomised controlled trial comparing 83 patients (male, n = 49) who underwent renal parenchymal core biopsy with coaxial method and 83 patients (male, n = 40) with noncoaxial method. The rate of complications, the number of glomerular profiles, and the procedural time were evaluated in a comparison of the two methods. Correlation between the presence of renal parenchymal disease and the rate of complication was also evaluated.ResultsThe procedural time was significantly shorter in the coaxial technique (coaxial group, 5 ± 1 min; noncoaxial group, 14 ± 2 min; p < 0.001). The rates of complications for the coaxial method was significantly lower than the noncoaxial method (coaxial group, 10.8 %; noncoaxial group, 24.1 %; p = 0.025). There was no significant correlation between gender and the rate of complication. The number of glomerular profiles was significantly higher in patents who underwent renal biopsy with the coaxial method (coaxial group, 18.2 ± 9.1; noncoaxial group, 8.6 ± 5.5; p < 0.001). In the whole study population, the rate of complications was significantly higher in patients with a pathologic renal parenchyma compared to those with a normal parenchyma (19/71 vs. 10/95; p = 0.006).ConclusionsRenal parenchymal biopsy using a coaxial needle is a faster and safer method with a lower rate of complications.

  3. Application of a New Guiding System in Percutaneous Biopsies

    International Nuclear Information System (INIS)

    Petsas, Theodore; Tsota, Irene; Kalogeropoulou, Christina P.; Liatsikos, Evangelos N.

    2007-01-01

    We herein describe the application of a new guiding system designed for percutaneous biopsies. The guiding system set is composed of a 0.41 mm (27G) stainless steel guide stylet and a 22G Chiba needle. Following the initial insertion of the Chiba needle, the stylet is advanced via the needle toward the lesion. The stylet serves either as a guide for the Chiba needle or as an exchange wire for the introduction of larger or cutting biopsy needles. The stylet can also be curved prior to its insertion to facilitate access to lesions which require needle redirection. The technique was applied to 117 cases (54 thoracic, 31 abdominal, 21 pelvic, and 11 vertebral lesions.) The main advantage of the stylet is its small diameter, rendering it atraumatic and permitting multiple punctures for the successful final targeting of the lesion. With this guiding set we achieved targeting of difficult lesions. Furthermore, larger needles were more easily introduced in locations that posed technical difficulties. No major complications were observed. The complication rate was comparable to that of the conventional biopsy technique. The technique using the guide stylet was easily performed and could be applied to almost all organs

  4. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases

    International Nuclear Information System (INIS)

    Puri, A.; Shingade, V.U.; Agarwal, M.G.; Anchan, C.; Juvekar, S.; Desai, S.; Jambhekar, N.A.

    2006-01-01

    Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the lesion for biopsy purposes. A prospective study of CT-guided core needle biopsies for deep-seated musculoskeletal lesions was conducted at a referral cancer institute over a 4-year period with the aim of assessing the safety and efficacy of the procedure. From January 2000 to December 2003, 136 consecutive CT-guided biopsy sessions were undertaken for musculoskeletal lesions in 128 patients comprising 73 males and 55 females. The following data was recorded in all patients: demographic data, suspected clinicoradiological diagnosis, data related to core biopsy session (date, site, approach, total time required in minutes, number of cores, surgeon satisfaction with adequacy of cores), patient discomfort, complications, histopathology report and number of further sessions if material obtained during the first biopsy session was not confirmatory. The sample obtained during the biopsy session was considered inconclusive if, in the opinion of the pathologist, inadequate or non-representative tissue had been obtained. The diagnosis was considered inaccurate if the final histopathological diagnosis did not match with the biopsy diagnosis, or if subsequent clinicoradiological evaluation at follow up did not correlate with the biopsy diagnosis in those patients who were treated with modalities other than surgery. In 121 patients, a single session was sufficient to obtain representative material, whilst for six patients two sessions, and for one patient three sessions were necessary. The time taken for biopsy, including the pre-biopsy CT examination time, varied from 15 min to 60 min (median 30 min). For 110 bony lesions 116 sessions were required, and for 18 soft-tissue lesions 20 sessions were required. 108 biopsy sessions yielded a diagnosis, whilst

  5. [A case of pulmonary abscess in which Haemophilus parainfluenzae and Streptococcus intermedius were isolated by percutaneous needle aspiration].

    Science.gov (United States)

    Miyamoto, Atsushi; Tsuboi, Eiyasu; Takaya, Hisashi; Sugino, Keishi; Sakamoto, Susumu; Kawabata, Masateru; Kishi, Kazuma; Narui, Koji; Homma, Sakae; Nakatani, Tatsuo; Nakata, Koichiro; Yoshimura, Kunihiko

    2006-08-01

    Some microbes, including the Bacteroides species, Staphylococcus aureus and Streptococcus milleri groups, can cause pulmonary abscess. Haemophilus parainfluenzae is usually categorized as one of the normal flora which colonizes in the ears and the nasopharynx, and it has been long considered that H. parainfluenzae has little pathogenicity in the lower respiratory tract and lung parenchymal. In this report, we present a case of pulmonary abscess caused by both H. parainfluenzae and Streptococcus intermedius. The patient was a 75-year-old man who had had total esophageo-gastrectomy because of esophageal cancer. He presented with purulent sputum, and chest X-ray film showed a dense consolidation in the right upper lung field. CT-guided transcutaneous fine needle aspiration was performed as a diagnostic procedure. Since both H. parainfluenzae and S. intermedius had been isolated from the lesion, pulmonary abscess caused by these two pathogens was diagnosed. The patient was treated with panipenem/betamipron, and his symptoms and pulmonary infiltrates on the chest X-ray film improved thereafter. So far, very few cases have been reported in which H. parainfluenzae caused lower respiratory tract infection. Although S. intermedius is known as one of the pathogens of pulmonary abscess, it is possible that H. parainfluenzae could also be pathogenic in infectious diseases of the lung.

  6. Percutaneous fine needle aspiration biopsy for the intrathoracic lesions: What is the meaning of non-diagnostic results?

    International Nuclear Information System (INIS)

    Kim, Min Ju; Lee, Jin Seong; Do, Kyung Hyun; Seo, Joon Beom; Song, Koun Sik; Lim, Tae Hwan

    2003-01-01

    To know what is the meaning of non-diagnostic results of fine needle aspiration biopsy (FNAB) and whether repeated aspiration is needed or not in those situations. We reviewed 1845 patients who underwent FNAB from 1997 to 2001. Non-diagnostic results of the first FNAB were divided into four groups: insufficient number of cells, inflammatory cells, necrotic debris and atypical cells. We analyzed final diagnosis of 531 patients who had non-diagnostic results from the first FNAB. Among them, 207 lesions were re-biopsied because of clinical and radiologic suspicion of malignancy. The diagnostic yield of repeated FNAB was analyzed and compared with the results of the first FNAB. Among 255 cases with 'inflammatory cells only' results, 120 cases were confirmed benignancy on follow-up. Twenty nine of 50 stypical cells (58%) were malignant of follow-up. One hundred one of 207 repeated FNAB resulted in the non-diagnostic reports, and 106 of 207 repeated FNAB were diagnosed as specific diagnosis. Among thirty lesions showing atypical cells on the repeated FNAB, 22 (73%) were identified as malignant neoplasms. When the specimen of FNAB shows atypical cells, the possibility of malignancy is very high. When the results of FNAB is non-diagnostic in the cases with clinical and radiological suspicion of malignancy, repeated FNAB procedures should be seriously considered and will be helpful for accurate specific diagnosis

  7. A novel technique of rotator cuff repair using spinal needle and suture loop

    Directory of Open Access Journals (Sweden)

    Muzaffar Nasir

    2010-11-01

    Full Text Available Abstract Background We present a simple technique of arthroscopic rotator cuff repair using a spinal needle and suture loop. Methods With the arthroscope laterally, a spinal needle looped with PDS is inserted percutaneously into the shoulder posteriorly and penetrated through the healthy posterior cuff tear margin. Anteriorly, another spinal needle loaded with PDS is inserted percutaneously to engage the healthy tissue at the anterior tear margin. The suture in the anterior needle is then delivered into the suture loop of the posterior needle using a suture retriever. The posterior needle and loop are then pulled out carrying the anterior suture with it. The two limbs of this suture are then retrieved through a cannula for knotting. The same procedure is then repeated for additional suturing. Suture anchors placed over the greater tuberosity are used to complete the repair. Conclusion This is an easy method of rotator cuff repair using simple instruments and lesser time, hence can be employed at centers with less equipment and at reduced cost to the patient.

  8. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  9. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  10. Use of cone-beam CT and live 3-D needle guidance to facilitate percutaneous nephrostomy and nephrolithotripsy access in children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, C.M. [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States); Kukreja, Kamlesh [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Singewald, Timothy; Johnson, Neil D.; Racadio, John M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Minevich, Eugene; Reddy, Pramod [Cincinnati Children' s Hospital Medical Center, Department of Urology, Cincinnati, OH (United States)

    2016-04-15

    Gaining access into non-dilated renal collecting systems for percutaneous nephrolithotripsy, particularly in patients with prohibitive body habitus and/or scoliosis, is often challenging using conventional techniques. To evaluate the feasibility of cone-beam CT for percutaneous nephrostomy placement for subsequent percutaneous nephrolithotripsy in children and adolescents. A retrospective review of percutaneous nephrostomy revealed use of cone-beam CT and 3-D guidance in 12 percutaneous nephrostomy procedures for 9 patients between 2006 and 2015. All cone-beam CT-guided percutaneous nephrostomies were for pre-lithotripsy access and all 12 were placed in non-dilated collecting systems. Technical success was 100%. There were no complications. Cone-beam CT with 3-D guidance is a technically feasible technique for percutaneous nephrostomy in children and adolescents, specifically for nephrolithotripsy access in non-dilated collecting systems. (orig.)

  11. Outcomes of percutaneous endoscopic gastrostomy tube insertion in respiratory impaired amyotrophic lateral sclerosis patients under noninvasive ventilation.

    Science.gov (United States)

    Czell, David; Bauer, Matthias; Binek, Janek; Schoch, Otto D; Weber, Markus

    2013-05-01

    Percutaneous endoscopic gastrostomy (PEG) tube placement in amyotrophic lateral sclerosis (ALS) patients with impaired respiratory function is associated with an increased risk of peri-procedural and post-interventional complications. It was the aim of the study to analyze peri- and post-interventional complications and survival after PEG tube placement under noninvasive ventilation (NIV) in ALS patients with various degrees of respiratory impairment. Twenty-six subjects were included in this retrospective case study. Prior to PEG tube placement, training with ventilatory support via an oronasal mask was performed with ALS subjects on the pneumology ward. PEG placement was then performed under continuous NIV. FVC, sniff nasal inspiratory pressure, and demographic data were assessed. Complication rates and 1-month and overall survival rates were analyzed. There were no deaths within 24 hours after PEG placement. One subject died within the first month. The mean survival rate after PEG was 12 ± 10 months (range 0.6-42 months). There was no difference in post-PEG survival between subjects with moderately (> 50%) and severely (NIV in ALS subjects.

  12. Implante subcutáneo de un carcinoma hepatocelular tras la punción aspiración con aguja fina Subcutaneous seeding of hepatocellular carcinoma after fine-needle percutaneous biopsy

    Directory of Open Access Journals (Sweden)

    D. Martínez Ramos

    2007-06-01

    Full Text Available Los implantes subcutáneos son una complicación rara tras la punción aspiración con aguja fina de los carcinomas hepatocelulares. Los autores describen un caso de implante subcutáneo neoplásico en una mujer de 70 años con cirrosis hepática por virus C complicada con un carcinoma hepatocelular. Se efectuó una punción aspiración con aguja fina en el segmento II hepático. El implante tumoral se desarrolló en el trayecto de la punción aspiración. La tumoración subcutánea fue extirpada quirúrgicamente y el estudio anatomopatológico confirmó que se trataba de un carcinoma hepatocelular bien diferenciado.Subcutaneous tumor seeding after fine-needle percutaneous biopsy for hepatocellular carcinoma is a rarely seen complication. The authors describe a case of subcutaneous neoplastic seeding in a 70-year-old woman with chronic hepatitis C virus complicated by hepatocellular carcinoma. Ultrasonically guided fine-needle aspiration biopsy was performed in segment II of the liver. The neoplastic seeding developed along the needle track used to carry out the fine-needle biopsy. The subcutaneous tumor was excised, and histological examination revealed a well-differentiated hepatocellular carcinoma.

  13. Risk of bleeding in patients undergoing percutaneous endoscopic gastrotrostomy (PEG tube insertion under antiplatelet therapy: a systematic review with a meta-analysis

    Directory of Open Access Journals (Sweden)

    Alfredo J. Lucendo

    2015-03-01

    Full Text Available Background and aim: Patients undergoing percutaneous endoscopic gastrostomy (PEG tube placement often are under antiplatelet therapy with a potential thromboembolic risk if these medications are discontinued. This systematic review aims to assess if maintaining aspirin and/or clopidogrel treatment increases the risk of bleeding following PEG placement. Methods: A systematic search of the MEDLINE, EMBASE, and SCOPUS databases was developed for studies investigating the risk of bleeding in patients on antiplatelet therapy undergoing PEG tube insertion. Summary estimates, including 95 % confidence intervals (CI, were calculated. A fixed or random effects model was used depending on heterogeneity (I². Publication bias risks were assessed by means of funnel plot analysis. Results: Eleven studies with a total of 6,233 patients (among whom 3,665 were undergoing antiplatelet treatment, met the inclusion criteria and were included in the quantitative summary. Any PEG tube placement-related bleeding was found in 2.67 % (95 % CI 1.66 %, 3.91 % of the entire population and in 2.7 % (95 % CI 1.5 %, 4.1 % of patients not receiving antiplatelet therapy. Pooled relative risk (RR for bleeding in patients under aspirin, when compared to controls, was 1.43 (95 % CI 0.89, 2.29; I² = 0 %; pooled RR for clopidogrel was 1.21 (95 % CI 0.48, 3.04; I² = 0 % and for dual antiplatelet therapy, 2.13; (95 % CI 0.77, 5.91; I² = 47 %. No significant publication bias was evident for the different medications analyzed. Conclusion: Antiplatelet therapy was safe among patients undergoing PEG tube insertion. Future prospective and randomized studies with larger sample sizes are required to confirm the results of this study.

  14. Percutaneous Extraction of Cement Leakage After Vertebroplasty Under CT and Fluoroscopy Guidance: A New Technique

    International Nuclear Information System (INIS)

    Amoretti, Nicolas; Huwart, Laurent

    2012-01-01

    Purpose: We report a new minimally invasive technique of extraction of cement leakage following percutaneous vertebroplasty in adults. Methods: Seven adult patients (five women, two men; mean age: 81 years) treated for vertebral compression fractures by percutaneous vertebroplasty had cement leakage into perivertebral soft tissues along the needle route. Immediately after vertebroplasty, the procedure of extraction was performed under computed tomography (CT) and fluoroscopy guidance: a Chiba needle was first inserted using the same route as the vertebroplasty until contact was obtained with the cement fragment. This needle was then used as a guide for an 11-gauge Trocar t’am (Thiebaud, France). After needle withdrawal, a 13-gauge endoscopy clamp was inserted through the cannula to extract the cement fragments. The whole procedure was performed under local anesthesia. Results: In each patient, all cement fragments were withdrawn within 10 min, without complication. Conclusions: This report suggests that this CT- and fluoroscopy-guided percutaneous technique of extraction could reduce the rate of cement leakage-related complications.

  15. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E. [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT (United Kingdom); Mari, Jean Martial [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom and GePaSud, University of French Polynesia, Faa’a 98702, French Polynesia (France); West, Simeon J. [Department of Anaesthesia, University College Hospital, Main Theatres, Maple Bridge Link Corridor, Podium 3, 235 Euston Road, London NW1 2BU (United Kingdom); Ginsberg, Yuval; David, Anna L. [Institute for Women’s Health, University College London, 86-96 Chenies Mews, London WC1E 6HX (United Kingdom); Ourselin, Sebastien [Center for Medical Imaging Computing, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2015-10-15

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction with the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With

  16. Fluoroscopically guided percutaneous jejunostomy: outcomes in 25 consecutive patients

    International Nuclear Information System (INIS)

    Yang, Z.Q.; Shin, J.H.; Song, H.-Y.; Kwon, J.H.; Kim, J.-W.; Kim, K.R.; Kim, J.-H.

    2007-01-01

    Aim: To assess the feasibility and safety of fluoroscopically guided percutaneous jejunostomy. Material and methods: Between May 1999 and August 2006 percutaneous jejunostomy was attempted in 25 patients. A 5 F vascular catheter (n = 20) or a 7.5 F multifunctional coil catheter (n = 5) was used to insufflate the jejunum. The distended jejunum was punctured using a 17 G needle (n = 19) or a 21 G Chiba needle (n = 6) with the inserted catheter as a target. A 12 or 14 F loop feeding tube was inserted after serial dilations. The technical success, complications, 30-day mortality, and in-dwelling period of the feeding tube placement were evaluated. Results: The technical success rate was 92% (23/25). Technical failures (n = 2) resulted from the inability to insufflate the jejunum secondary to failure to pass the catheter through a malignant stricture at the oesophagojejunostomy site and thus subsequent puncture of the undistended jejunum failed, or failure to introduce the Neff catheter into the jejunum. Pericatheter leakage with pneumoperitoneum was a complication in three patients (12%) and was treated conservatively. The 30-day mortality was 13% (3/23); however, there was no evidence that these deaths were attributed to the procedure. Except for four patients who were lost to follow-up and two failed cases, 15 of the 19 jejunostomy catheters were removed because of patient death (n = 12) or completion of treatment (n = 3), with a mean and median in-dwelling period of 231 and 87 days, respectively. Conclusions: Fluoroscopically guided percutaneous jejunostomy is a feasible procedure with a high technical success and a low complication rate. In addition to a 17 G needle, a 21 G needle can safely be used to puncture the jejunum

  17. Percutaneous radiofrequency treatment of osteoid osteoma using cool-tip electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain)]. E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain); Ortiz, Eduardo [Departamento de Cirugia ortopedica, Fundacion Hospital Alcorcon, Madrid (Spain)

    2005-12-15

    Objectives: To report our experience with percutaneous cool-tip radiofrequency ablation of osteoid osteomas and to evaluate clinical outcome. Methods and material: Forty-one patients with clinically and radiologically suspected osteoid osteoma were seen over a 48-month period (27 males and 14 females with a mean age of 18.7 years; range 5-43 years). Thirty-eight patients were treated by computed tomography (CT)-guided percutaneous radiofrequency ablation. The procedure was performed under regional or general anaesthesia. After location of the nidus, a 14G-bone biopsy needle is introduced into the nidus. Sampling is performed with a 17G-bone biopsy needle using a coaxial technique. The radiofrequency needle with a 10 mm active tip (cool-tip) is inserted through the biopsy needle and is connected to the radiofrequency generator for 6-8 min. Results: Primary success was obtained in 37 patients (97%) with a 100% secondary success rate. All patients are currently pain-free. No major complications occurred. Patients could resume unrestricted normal activity within 24 h. Conclusions: Percutaneous radiofrequency ablation of osteoid osteomas is an efficient and safe method that can be considered the procedure of choice for most cases.

  18. Processing and Characterization of Needled Carbon Composites

    Science.gov (United States)

    2015-12-01

    needle is used to insert high strength yarns (i.e., threads) through the dry fabric or prepreg laminate , leaving a loose thread loop underneath [9-11...capability which uses commercially-available felting needles to insert z-fibers into composite laminates at different angles (±45/90°) relative to the... laminate plane. Previous work with needled glass/epoxy composites has shown a 270% improvement in Mode I interlaminar fracture toughness when needled

  19. Brachytherapy needle deflection evaluation and correction

    International Nuclear Information System (INIS)

    Wan Gang; Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    In prostate brachytherapy, an 18-gauge needle is used to implant radioactive seeds. This thin needle can be deflected from the preplanned trajectory in the prostate, potentially resulting in a suboptimum dose pattern and at times requiring repeated needle insertion to achieve optimal dosimetry. In this paper, we report on the evaluation of brachytherapy needle deflection and bending in test phantoms and two approaches to overcome the problem. First we tested the relationship between needle deflection and insertion depth as well as whether needle bending occurred. Targeting accuracy was tested by inserting a brachytherapy needle to target 16 points in chicken tissue phantoms. By implanting dummy seeds into chicken tissue phantoms under 3D ultrasound guidance, the overall accuracy of seed implantation was determined. We evaluated methods to overcome brachytherapy needle deflection with three different insertion methods: constant orientation, constant rotation, and orientation reversal at half of the insertion depth. Our results showed that needle deflection is linear with needle insertion depth, and that no noticeable bending occurs with needle insertion into the tissue and agar phantoms. A 3D principal component analysis was performed to obtain the population distribution of needle tip and seed position relative to the target positions. Our results showed that with the constant orientation insertion method, the mean needle targeting error was 2.8 mm and the mean seed implantation error was 2.9 mm. Using the constant rotation and orientation reversal at half insertion depth methods, the deflection error was reduced. The mean needle targeting errors were 0.8 and 1.2 mm for the constant rotation and orientation reversal methods, respectively, and the seed implantation errors were 0.9 and 1.5 mm for constant rotation insertion and orientation reversal methods, respectively

  20. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    International Nuclear Information System (INIS)

    Koethe, Yilun; Xu, Sheng; Velusamy, Gnanasekar; Wood, Bradford J.; Venkatesan, Aradhana M.

    2014-01-01

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  1. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Koethe, Yilun [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Duke University School of Medicine, Durham, NC (United States); Xu, Sheng [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); Velusamy, Gnanasekar [Perfint Healthcare Pvt. Ltd., Chennai (India); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Venkatesan, Aradhana M. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States)

    2014-03-15

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  2. Computed-Tomography-Guided Percutaneous Core Needle Biopsies of Suspected Malignant Lymphomas: Impact of Biopsy, Lesion, and Patient Parameters on Diagnostic Yield

    International Nuclear Information System (INIS)

    Hesselmann, V.; Zaehringer, M.; Krug, B.; Wesselmann, C.; Haferkamp, K.; Wickenhauser, C.; Lackner, K.

    2004-01-01

    Purpose: To investigate the diagnostic yield of core needle biopsy in patients with malignant lymphoma. Material and Methods: Computed-tomography-guided core needle biopsies in patients with malignant lymphoma performed in the period 1996 to 2001 were evaluated retrospectively. A biopsy was considered as 'fully diagnostic' if a histological diagnosis, including the histologic subtype in the event of malignant lymphoma, was achieved and the clinical course and CT follow-up of at least 6 months confirmed the biopsy results. A biopsy was regarded as 'partly diagnostic' if histological work-up defined malignant lymphoma but not the histological subtype, and if histological diagnosis bore therapeutic relevance. Diagnostic yield was correlated with features such as size of specimen, location and depth of the target lesion, and experience of the investigator. Results: 45 biopsies were performed in 40 patients. With respect to definite histopathological diagnosis, 31 biopsies (68.9%) were diagnostic and 14 (31.1%) non-diagnostic. In 4 cases (8.8%), biopsies yielded partly diagnostic results, since therapy could be scheduled after biopsy without final sub-classification. Statistical analysis of biopsy parameters revealed that sample sizes were significantly larger in the diagnostic group. Conclusion: CT-guided biopsy can be considered as an alternative for lymphoma diagnosis and should be the first interventional procedure. The most important parameter for diagnostic success is the size of the specimen

  3. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    Science.gov (United States)

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (ptechnical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. A prototype percutaneous transhepatic cholangiography training simulator with real-time breathing motion.

    Science.gov (United States)

    Villard, P F; Vidal, F P; Hunt, C; Bello, F; John, N W; Johnson, S; Gould, D A

    2009-11-01

    We present here a simulator for interventional radiology focusing on percutaneous transhepatic cholangiography (PTC). This procedure consists of inserting a needle into the biliary tree using fluoroscopy for guidance. The requirements of the simulator have been driven by a task analysis. The three main components have been identified: the respiration, the real-time X-ray display (fluoroscopy) and the haptic rendering (sense of touch). The framework for modelling the respiratory motion is based on kinematics laws and on the Chainmail algorithm. The fluoroscopic simulation is performed on the graphic card and makes use of the Beer-Lambert law to compute the X-ray attenuation. Finally, the haptic rendering is integrated to the virtual environment and takes into account the soft-tissue reaction force feedback and maintenance of the initial direction of the needle during the insertion. Five training scenarios have been created using patient-specific data. Each of these provides the user with variable breathing behaviour, fluoroscopic display tuneable to any device parameters and needle force feedback. A detailed task analysis has been used to design and build the PTC simulator described in this paper. The simulator includes real-time respiratory motion with two independent parameters (rib kinematics and diaphragm action), on-line fluoroscopy implemented on the Graphics Processing Unit and haptic feedback to feel the soft-tissue behaviour of the organs during the needle insertion.

  5. The rendezvous technique involving insertion of a guidewire in a percutaneous transhepatic gallbladder drainage tube for biliary access in a case of difficult biliary cannulation.

    Science.gov (United States)

    Sunada, Fumiko; Morimoto, Naoki; Tsukui, Mamiko; Kurata, Hidekazu

    2017-05-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is a diagnostic method and treatment approach for biliary diseases. However, biliary cannulation can be difficult in some cases. We performed ERCP in a 97-year-old woman with abdominal pain resulting from acute cholangitis caused by choledocholithiasis and observed difficult biliary cannulation. Eventually, the patient was successfully treated with the rendezvous technique. We could not cannulate the biliary duct during ERCP twice. Therefore, we placed a percutaneous transhepatic gallbladder drainage (PTGBD) tube without intrahepatic dilation. The rendezvous technique was performed using the PTGBD tube. The patient did not experience pancreatitis or perforation.

  6. Percutaneous angioscopy

    International Nuclear Information System (INIS)

    Beck, A.

    1987-01-01

    In dogs and 11 patients a new endoscopic method for arteries has been developed. The approach is transfemoral, and endoscopy is combined with angiography, percutaneous transluminal angioplasty (PTA), and local lysis. An ultrathin endoscope with a diameter of 2.4 mm is used, which also provides a working channel with a diameter of 0.4 mm. Guide wires, contrast media, and drugs for local lysis can be inserted through this channel. Under fluoroscopic control, the endoscope is placed in the region of interest, followed by a special method for decreasing blood flow. Endoscopy is documented by video or by a high-speed camera. No complications have occurred. In all patients, it was possible to demonstrate the results of dilatation, recanalization, or local lysis before and after the interventional procedure. (orig.) [de

  7. Antegrade jj stenting after percutaneous renal procedures: The ‘pull and push’ technique

    Science.gov (United States)

    Ratkal, Jaideep M.; Sharma, Elias

    2014-01-01

    A JJ stent is inserted antegradely after percutaneous renal procedures like percutaneous nephrolithotomy (PCNL) for renal calculus disease, and for endopyelotomy for pelvi-ureteric junction obstruction. We describe a technique for antegrade stent insertion after PCNL. PMID:26413327

  8. Antegrade jj stenting after percutaneous renal procedures: The 'pull and push' technique.

    Science.gov (United States)

    Ratkal, Jaideep M; Sharma, Elias

    2015-06-01

    A JJ stent is inserted antegradely after percutaneous renal procedures like percutaneous nephrolithotomy (PCNL) for renal calculus disease, and for endopyelotomy for pelvi-ureteric junction obstruction. We describe a technique for antegrade stent insertion after PCNL.

  9. [Cost-effectiveness of percutaneous core needle breast biopsy (CNBB) versus open surgical biopsy (OSB) of nonpalpable breast lesions: metaanalysis and cost evaluation for German-speaking countries].

    Science.gov (United States)

    Gruber, R; Bernt, R; Helbich, T H

    2008-02-01

    To analyze the cost-effectiveness of percutaneous image-guided CNBB (stereotactic-/ultrasound-guided; large/vacuum-assisted) of non-palpable breast lesions vs. OSB and to compare and discuss the results reported in the literature with results for German-speaking countries. A key word search in three databases, limited to the period from 1/1994 to 12/2006 was performed. Only original papers were selected. No published articles for German-speaking countries were identified; therefore a comprehensive data collection was made. On the basis of 377 abstracts, nine studies were evaluated for final assessment. The data of German-speaking countries were compared with results reported in the literature. This study demonstrates that CNBB compared to OSB leads to reduction in cost ranging from 51-96 %. The cost reduction depends on biopsy modality and lesion type and is subject to national fluctuations. CNBB can replace a surgical procedure in 71-85 % of cases. Use of CNBB as an alternative to OSB has the potential to substantially reduce healthcare costs. The data are based almost exclusively on the North American literature. A potential cost reduction in the Netherlands and Switzerland confirms these findings. Future work must include cost evaluation studies for German-speaking countries since this is an issue with important national economic ramifications.

  10. Risk Factors of Catheter-related Bloodstream Infection With Percutaneously Inserted Central Venous Catheters in Very Low Birth Weight Infants: A Center's Experience in Taiwan

    Directory of Open Access Journals (Sweden)

    Jen-Fu Hsu

    2010-12-01

    Conclusion: It is important to avoid inserting a PICC at the femoral site. Strict catheter care protocol should also be applied to reduce local site bacterial colonization and removal of PICCs as soon as they are no longer essential for patient care to reduce the incidence of infection.

  11. [Needling technique of Professor Li Yan-Fang].

    Science.gov (United States)

    Li, Li-Jun

    2014-01-01

    Experiences of needling techniques of Professor LI Ya- fang is introduced in this article. Gentle and superficial insertion is adopted by Professor LI in clinic. Emphases are put on the qi regulation function, needling sensation to the affected region and insertion with both hands, especially the function of the left hand as pressing hand. The gentle and superficial insertion should be done as the follows: hold the needle with the right hand, press gently along the running course of meridians with the left hand to promote qi circulation, hard pressing should be applied at acupoints to disperse the local qi and blood, insert the needle gently and quickly into the subcutaneous region with the right hand, and stop the insertion when patient has the needling sensation. While the fast needling is characterized with shallow insertion and swift manipulation: the left hand of the manipulator should press first along the running course of the meridian, and fix the local skin, hold the needle with the right hand and insert the needle quickly into the acupoint. Withdrawal of the needle should be done immediately after the reinforcing and reducing manipulations. Professor LI is accomplished in qi regulation. It is held by him that regulating qi circulation is essence of acupuncture, letting the patient get the needling sensation is the most important task of needling. Lifting, thrusting and rotation manipulations should be applied to do reinforcing or reducing. The tissue around the tip of the needle should not be too contracted or too relaxed, and the resistance should not be too strong or too weak. The feeling of the insertion hand of the practitioner should not be too smooth or too hesitant. Needle should be inserted into the skin quickly at the moment of hard pressing by the left hand. And then, slow rotation and gentle lifting and thrusting can be applied to promote the needling sensation like electric current pass through and to reach the affected region along the

  12. Novel Double-Needle System That Can Prevent Intravascular Injection of Any Filler

    Directory of Open Access Journals (Sweden)

    Hsiang Huang, MD

    2017-09-01

    Full Text Available Summary:. A new type of needle system combines 2 parts, an inner needle and an outer needle. The inner needle is used for filler injection and the outer needle acts as a guiding needle that can observe blood reflow when inserting into the vessel lumen during injection process. This new needle system can be used for all kinds of filler, providing real time monitoring for physician and preventing intravascular injection of any filler.

  13. Percutaneous transhepatic sphincterotomy

    International Nuclear Information System (INIS)

    Gandin, G.; Zanon, E.; Righi, D.; Fonio, P.; Ferrari, A.; Recchia, S.

    1990-01-01

    The authors describe the techique employed for percutaneous trans-hepatic sphincterotomy as performed on 3 patients with common bile duct (CBD) stones. In all patients, previous endoscopic attempt had failed for anatomical reasons (Billroth II gastric resection or partial gastric resection with brown anastomosis), and the ampulla could not be correctly incannulated with the sphincterotome. In all aptients endoscopy was useful to check the position of the diethermic loop inserted percutaneously. Conplete and immediate success was obtained in all 3 cases. No major complications occurred during transhepatic treatment. To date, 1 recurrence has been observed, and the patient has been retreated with bilioplasty. All patients were followed after 5-6 months with US, plain X-rays of the abdomen and blood tests (γGt, alkaline phosphatase, and bilirubinemia). The authors suggest that percutaneous transhepatic sphincterotomy be employed electively in patients with biliary tree diseases in case the endoscopic approach failes

  14. Image guided percutaneous splenic interventions

    International Nuclear Information System (INIS)

    Kang, Mandeep; Kalra, Naveen; Gulati, Madhu; Lal, Anupam; Kochhar, Rohit; Rajwanshi, Arvind

    2007-01-01

    Aim: The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. Materials and methods: We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous splenic interventions were performed after informed consent in 89 patients: 64 men and 25 women who ranged in age from 5 months to 71 years (mean, 38.4 years) under ultrasound (n = 93) or CT (n = 2) guidance. The procedures performed were fine needle aspiration biopsy of focal splenic lesions (n = 78) and aspiration (n = 10) or percutaneous catheter drainage of a splenic abscess (n = 7). Results: Splenic fine needle aspiration biopsy was successful in 62 (83.78%) of 74 patients with benign lesions diagnosed in 43 (58.1%) and malignancy in 19 (25.67%) patients. The most common pathologies included tuberculosis (26 patients, 35.13%) and lymphoma (14 patients, 18.91%). Therapeutic aspiration or pigtail catheter drainage was successful in all (100%) patients. There were no major complications. Conclusions: Image-guided splenic fine needle aspiration biopsy is a safe and accurate technique that can provide a definitive diagnosis in most patients with focal lesions in the spleen. This study also suggests that image-guided percutaneous aspiration or catheter drainage of splenic abscesses is a safe and effective alternative to surgery

  15. TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

    International Nuclear Information System (INIS)

    Borot de Battisti, M; Maenhout, M; Lagendijk, J J W; Van Vulpen, M; Moerland, M A; Denis de Senneville, B; Hautvast, G; Binnekamp, D

    2016-01-01

    Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact

  16. Observations of needle-tissue interactions

    NARCIS (Netherlands)

    Misra, Sarthak; Reed, Kyle B.; Ramesh, K.T.; Okamura, Allison M.

    2009-01-01

    Needles with asymmetric bevel tips naturally bend when they are inserted into soft tissue. In this study, we present an analytical model for the loads developed at the bevel tip during needle-tissue interaction. The model calculates the loads based on the geometry of the bevel edge and gel material

  17. Fine Needle Aspiration Biopsy in a Rural Family Practice

    African Journals Online (AJOL)

    ultrasound scan. A 21-gauge 1½-inch or 23-gauge 1¼-inch needle, attached to a 10-mL disposable plastic syringe, was used for FNAB of superficial masses. For percutaneous FNAB of deep-seated organs and masses, a 23 gauge 1¼-inch needle or 3½-inch spinal needle was used. The aspirate was spread on slides and ...

  18. Percutaneous Ultrasound-Guided Thrombin Injection in Iatrogenic Arterial Pseudoaneurysms: Effectiveness and Complications

    International Nuclear Information System (INIS)

    Koh, Young Hwan; Kim, Hak Soo; Kim, Hyung Sik; Min, Seung Kee

    2005-01-01

    To evaluate and describe the efficacy and side effects of a percutaneous thrombin injection under ultrasonography guidance for the treatment of iatrogenic pseudo aneurysms Eighteen consecutive iatrogenic pseudo aneurysm cases were treated with a thrombin injection. The thrombin was injected into the pseudo aneurysm cavity using a 22-gauge needle under ultrasonographic guidance. The causes of the pseudo aneurysms are as follows: post coronary angiography (9 cases), percutaneous coronary balloon angioplasty (5 cases), cerebral angiography (1 case), transhepatic chemo embolization (1 case), percutaneous trans femoral arterial stent insertion (1 case) and bone marrow aspiration for a marrow transplant (1 case). Only one case required a secondary thrombin injection due to recurrent flow in the pseudo aneurysm lumen, which was detected at the follow up Doppler ultrasound. Other seventeen cases were successfully treated on the first trial. There were no technical failures or complication related to the procedure. The average amount of thrombin injected was 733 IU. Nine out of 18 treated patients (50%) showed mild reactions to the thrombin including mild fever (4 cases), chilling sensation (3 cases), a chilling sensation with mild dyspnea (1 case), mild chest discomfort (1 case) after the thrombin injection. All these side effects were transient and improved several hours later. All the iatrogenic pseudo aneurysms were treated successfully with an ultrasound-guided percutaneous thrombin injection. There was a high rate of hypersensitivity to the bovine thrombin, which precaution should be taken to prevent more serious side effects

  19. Percutaneous Ultrasound-Guided Thrombin Injection in Iatrogenic Arterial Pseudoaneurysms: Effectiveness and Complications

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Young Hwan [Boramae Hospital, Seoul (Korea, Republic of); Kim, Hak Soo; Kim, Hyung Sik; Min, Seung Kee [Gachon Medical School, Incheon (Korea, Republic of)

    2005-09-15

    To evaluate and describe the efficacy and side effects of a percutaneous thrombin injection under ultrasonography guidance for the treatment of iatrogenic pseudo aneurysms Eighteen consecutive iatrogenic pseudo aneurysm cases were treated with a thrombin injection. The thrombin was injected into the pseudo aneurysm cavity using a 22-gauge needle under ultrasonographic guidance. The causes of the pseudo aneurysms are as follows: post coronary angiography (9 cases), percutaneous coronary balloon angioplasty (5 cases), cerebral angiography (1 case), transhepatic chemo embolization (1 case), percutaneous trans femoral arterial stent insertion (1 case) and bone marrow aspiration for a marrow transplant (1 case). Only one case required a secondary thrombin injection due to recurrent flow in the pseudo aneurysm lumen, which was detected at the follow up Doppler ultrasound. Other seventeen cases were successfully treated on the first trial. There were no technical failures or complication related to the procedure. The average amount of thrombin injected was 733 IU. Nine out of 18 treated patients (50%) showed mild reactions to the thrombin including mild fever (4 cases), chilling sensation (3 cases), a chilling sensation with mild dyspnea (1 case), mild chest discomfort (1 case) after the thrombin injection. All these side effects were transient and improved several hours later. All the iatrogenic pseudo aneurysms were treated successfully with an ultrasound-guided percutaneous thrombin injection. There was a high rate of hypersensitivity to the bovine thrombin, which precaution should be taken to prevent more serious side effects

  20. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-06-15

    Jun 15, 2011 ... guided PFNAB/US-guided PNCB was the diagnostic test in 23.33% cases. It confirmed a highly ..... provides guidance in multiple axial, longitudinal and .... Source of Support: Nil, Con.ict of Interest: None declared. Gani, et al.

  1. Robotic needle steering: design, modeling, planning, and image guidance

    NARCIS (Netherlands)

    Cowan, Noah J.; Goldberg, Ken; Chirikjian, Gregory S.; Fichtinger, Gabor; Alterovitz, Ron; Reed, Kyle B.; Kallem, Vinutha; Misra, Sarthak; Park, Wooram; Okamura, Allison M.; Rosen, Jacob; Hannaford, Blake; Satava, Richard M.

    2010-01-01

    This chapter describes how advances in needle design, modeling, planning, and image guidance make it possible to steer flexible needles from outside the body to reach specified anatomical targets not accessible using traditional needle insertion methods. Steering can be achieved using a variety of

  2. Torsional Dynamics of Steerable Needles: Modeling and Fluoroscopic Guidance

    Science.gov (United States)

    Swensen, John P.; Lin, MingDe; Okamura, Allison M.; Cowan, Noah J.

    2017-01-01

    Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod—such as a tip-steerable needle—during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups—stereo camera feedback in semi-transparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue— demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026

  3. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  4. Pleural space infections after image-guided percutaneous drainage of infected intraabdominal fluid collections: a retrospective single institution analysis.

    Science.gov (United States)

    Avella, Diego M; Toth, Jennifer W; Reed, Michael F; Gusani, Niraj J; Kimchi, Eric T; Mahraj, Rickeshvar P; Staveley-O'Carroll, Kevin F; Kaifi, Jussuf T

    2015-04-11

    Percutaneous drainage of infected intraabdominal fluid collections is preferred over surgical drainage due to lower morbidity and costs. However, it can be a challenging procedure and catheter insertion carries the potential to contaminate the pleural space from the abdomen. This retrospective analysis demonstrates the clinical and radiographic correlation between percutaneous drainage of infected intraabdominal collections and the development of iatrogenic pleural space infections. A retrospective single institution analysis of 550 consecutive percutaneous drainage procedures for intraabdominal fluid collections was performed over 24 months. Patient charts and imaging were reviewed with regard to pleural space infections that were attributed to percutaneous drain placements. Institutional review board approval was obtained for conduct of the study. 6/550 (1.1%) patients developed iatrogenic pleural space infections after percutaneous drainage of intraabdominal fluid collections. All 6 patients presented with respiratory symptoms and required pleural space drainage (either by needle aspiration or chest tube placement), 2 received intrapleural fibrinolytic therapy and 1 patient had to undergo surgical drainage. Pleural effusion cultures revealed same bacteria in both intraabdominal and pleural fluid in 3 (50%) cases. A video with a dynamic radiographic sequence demonstrating the contamination of the pleural space from percutaneous drainage of an infected intraabdominal collection is included. Iatrogenic pleural space infections after percutaneous drainage of intraabdominal fluid collections occur at a low incidence, but the pleural empyema can be progressive requiring prompt chest tube drainage, intrapleural fibrinolytic therapy or even surgery. Expertise in intraabdominal drain placements, awareness and early recognition of this complication is critical to minimize incidence, morbidity and mortality in these patients.

  5. Tumour seeding after percutaneous cryoablation for hepatocellular carcinoma

    Science.gov (United States)

    Wang, Chun-Ping; Wang, Hong; Qu, Jian-Hui; Lu, Yin-Ying; Bai, Wen-Lin; Dong, Zheng; Gao, Xu-Dong; Rong, Guang-Hua; Zeng, Zhen; Yang, Yong-Ping

    2012-01-01

    AIM: To assess the rate and risk factors for tumour seeding in a large cohort of patients. METHODS: Over an 8-year period, 1436 hepatocellular carcinoma (HCC) patients with 2423 tumour nodules underwent 3015 image-guided percutaneous cryoablation sessions [1215 guided by ultrasonography and 221 by spiral computed tomography (CT)]. Follow-up CT or magnetic resonance imaging was performed every 3 mo. The detailed clinical data were recorded to analyse the risk factors for seeding. RESULTS: The median follow-up time was 18 (range 1-90) mo. Seeding was detected in 11 patients (0.76%) at 1-24 (median 6.0) mo after cryoablation. Seeding occurred along the needle tract in 10 patients and at a distant location in 1 patient. Seeded tumours usually showed similar imaging and histopathological features to the primary HCCs. Univariate analyses identified subcapsular tumour location and direct subcapsular needle insertion as risk factors for seeding. Multivariate analysis showed that only direct subcapsular needle insertion was an independent risk factor for seeding (P = 0.017; odds ratio 2.57; 95%CI: 1.47-3.65). Seeding after cryoablation occurred earlier in patients with poorly differentiated HCC than those with well or moderately differentiated HCC [1.33 ± 0.577 mo vs 11.12 ± 6.896 mo; P = 0.042; 95%CI: (-19.115)-(-0.468)]. CONCLUSION: The risk of seeding after cryoablation for HCC is small. Direct puncture of subcapsular tumours should be avoided to minimise seeding. PMID:23236233

  6. Mosquito inspired medical needles

    DEFF Research Database (Denmark)

    Lenau, Torben Anker; Hesselberg, Thomas; Drakidis, Alexandros Dimitrios

    2017-01-01

    The stinging proboscis in mosquitos have diameters of only 40-100 μm which is much less than the thinnest medical needles and the mechanics of these natural stinging mechanisms have therefore attracted attention amongst developers of injection devises. The mosquito use a range of different...... strategies to lower the required penetration force hence allowing a thinner and less stiff proboscis structure. Earlier studies of the mosquito proboscis insertion strategies have shown how each of the single strategies reduces the required penetration force. The present paper gives an overview...... of the advanced set of mechanisms that allow the mosquito to penetrate human skin and also presents other biological mechanisms that facilitate skin penetration. Results from experiments in a skin mimic using biomimetic equivalents to the natural mechanisms are presented. This includes skin stretching, insertion...

  7. Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Topal, U.; Berkman, Yahya M.

    2005-01-01

    Purpose: Occasionally bleeding along the needle trajectory is observed at post-biopsy computed tomographic sections. This study was designed to evaluate the possible effect of needle tract bleeding on the occurrence of pneumothorax and on requirement of chest tube insertion. Materials and methods: Two hundred eighty-four needle biopsies performed in 275 patients in whom the needle traversed the aerated lung parenchyma were retrospectively reviewed. Bleeding along the needle tract, occurrence of pneumothorax and need for chest tube insertion, type and size of the needle, size of the lesion, length of the lung traversed by the needle, presence or absence of emphysema were noted. Effect of these factors on the rate of pneumothorax and needle-tract bleeding was evaluated. The data were analyzed by χ 2 test. Results: Pneumothorax developed in 100 (35%) out of 284 procedures requiring chest tube placement in 16 (16%). Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P 0.05). However, analysis of the relation between length of lung traversed by the needle, tract-bleeding and pneumothorax rate indicated that tract-bleeding had a preventive effect on development of pneumothorax (P 0.05). Conclusion: Bleeding in the needle tract has a preventive effect on the occurrence of the pneumothorax in deep-seated lesions and in the presence of emphysema, although it does not affect the overall rate of pneumothorax

  8. Percutaneous treatment in patients presenting with malignant cardiac tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Marcy, P.Y. [Antoine Lacassagne Center, Interventional Radiology Department, Nice (France); Bondiau, P.Y. [Antoine Lacassagne Center, Radiation Therapy Department, Nice (France); Brunner, P. [Centre Hospitalier Princesse, Grace (Monaco). Interventional Radiology Department

    2005-09-01

    The percutaneous treatment of pericardial effusion resulting in cardiac tamponade has undergone an evolution in recent years with the use of less invasive drainage techniques in selected cases. To determine optimal therapy modalities for oncology patients with malignant pericardial tamponade (MPT), the authors review their institutional experience with percutaneous needle puncture routes, means of imaging-guided drainage and percutaneous management of the pericardial fluid effusion (pericardial sclerosis and balloon pericardiotomy). Advantages and limits of the percutaneous techniques will be compared to the surgical treatment. (orig.)

  9. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  10. Analysis of diagnositc accuracy with CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Haiyan; Zhuang Yiping; Zhang Jin; Feng Yong; Zhang Xiao; Xu Lin

    2007-01-01

    Objective: To evaluate the factors which may affect the diagnostic accmracy of CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions. Methods: CT-guided percutaneous transthoracic lung biopsy was performed in 264 patients, all of which were proved by surgical pathology or clinical follow-up. A logistic regression analysis was used to investigate the relationship between the location and the size of the lesions and insertion depth of biopsy needles and the diagnostic accuracy of CT-guided percutaneous transthomcic lung biopsy. The complication rate including pneumatothorax and bleeding rate were record. Results: The diagnostic accuracy was 87.5%. Both the pneumothorax and the bleeding of lesion were 1.9%. The size of lesion was suggested by Logistic regression analysis had a significant influence on the diagnostic accuracy (Wald=12.891, P=0.00034, OR=0.96). Conclusion: CT-guided pereumneous transthoracic lung biopsy has a high diagnostic accuracy for pulmonary lesions. The size of the lesions had significant effect on the diagnostic accuracy. (authors)

  11. [Study on pulmonary lesions in which nontuberculous mycobacteria were detected by percutaneous aspiration--a proposal to add "culture positivity of percutaneous aspiration material" to the bacteriological diagnostic criteria of pulmonary nontuberculous mycobacterial diseases].

    Science.gov (United States)

    Nakahara, Yasuharu; Mochizuki, Yoshiro; Kawamura, Tetsuji; Sasaki, Shin; Morimoto, Akie; Mizumori, Yasuyuki; Tsukamoto, Hiroaki; Watanabe, Etsuko; Yokoyama, Toshihide

    2013-03-01

    Culture positivity of percutaneous aspiration material" is not included in the current bacteriological criteria for diagnosis of pulmonary nontuberculous mycobacterial (NTM) diseases, which were published by the Infectious Diseases Society of America (IDSA)/American Thoracic Society (ATS) in 2007 or those released by the Japanese Society for Tuberculosis in 2008. However, percutaneous aspiration is a reliable technique for the detection of causative microorganisms isolated from the focus of infection. We discuss the benefits of including positive culture of percutaneous aspiration material in the bacteriological diagnostic criteria of pulmonary NTM diseases. We reviewed the radiological images and clinical courses of pulmonary diseases in which NTM cultures were obtained from percutaneously aspirated materials at our hospital from 1991 to 2011. Aspiration was carried out under local anesthesia, usually with fluoroscopic guidance. After percutaneous insertion of a 22-gauge needle attached to a 20-mL syringe containing about 3 mL of saline, the lesion specimen was withdrawn together with the saline. After the needle was pulled out, the aspirated material and saline were transferred to test tubes for cytological and microbiological examinations. In patients with thin-walled cavitary lesions, saline was injected into the cavity and then aspirated. Percutaneous aspiration was performed in 2,742 patients and NTM disease was detected in 51 patients. Of these 51 patients, 12 had solitary nodular lesions, and in many of these patients, no NTM bacilli could be detected in the sputa or bronchial washing specimens. Mycobacterium avium was identified in 10 of the 12 cases. Four of these 10 patients were followed up after their diagnosis without any treatment: 3 showed spontaneous reduction in lesion size, while 1 patient's condition remained unchanged. Four of the remaining 6 cases were treated with anti-NTM medications, and lesion size reduced in 2 cases, while no change or

  12. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    OpenAIRE

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2011-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retrac...

  13. Percutaneous drainage of fluid collection in the pleural and pericardial spaces. Perkutan pleura- og perikarddrenasje

    Energy Technology Data Exchange (ETDEWEB)

    Drolsum, A.; Skjennald, A. (Ullevaal sykehus, Oslo (Norway))

    1994-11-01

    Both MRI, CT and sonography will give a good presentation of fluid collection in pleura and pericardium. Sonography is the ideal imaging method for monitoring interventional procedures. Its ability to visualize superficial fluid collection and its real-time capability allows precise control of needle and catheter insertions. If the abnormality is poorly seen with ultrasound, often because of air in the collection, CT can be used as a guidance system. Diagnostic thoracocentesis and pericardiocentesis are performed mainly to exclude malignancy and infections, and the punctions are made with small needles. Therapeutic thoracocentesis is usually performed to relieve dyspnoe and small catheters are used. Drainage of empyema is performed with larger catheters because of the high viscosity of the infected fluid. Patients with threatening cardiac tamponade will often respond immediately to drainage of the pericardial space by catheter. These procedures can be done with local anesthesia only. If complications occur, it is mainly the pneumothorax that has to be treated. This can be managed directly under the procedure as the drainage catheter is attached to continuous pleural suction, or a catheter can be inserted in the pleural space after diagnostic punction. Patients with coagulation abnormalities must be evaluated especially before any intervention, otherwise there are no contraindications for these image-guided percutaneous procedures. 14 refs., 6 figs.

  14. Volume navigation with contrast enhanced ultrasound and image fusion for percutaneous interventions: first results.

    Directory of Open Access Journals (Sweden)

    Ernst Michael Jung

    Full Text Available OBJECTIVE: Assessing the feasibility and efficiency of interventions using ultrasound (US volume navigation (V Nav with real time needle tracking and image fusion with contrast enhanced (ce CT, MRI or US. METHODS: First an in vitro study on a liver phantom with CT data image fusion was performed, involving the puncture of a 10 mm lesion in a depth of 5 cm performed by 15 examiners with US guided freehand technique vs. V Nav for the purpose of time optimization. Then 23 patients underwent ultrasound-navigated biopsies or interventions using V Nav image fusion of live ultrasound with ceCT, ceMRI or CEUS, which were acquired before the intervention. A CEUS data set was acquired in all patients. Image fusion was established for CEUS and CT or CEUS and MRI using anatomical landmarks in the area of the targeted lesion. The definition of a virtual biopsy line with navigational axes targeting the lesion was achieved by the usage of sterile trocar with a magnetic sensor embedded in its distal tip employing a dedicated navigation software for real time needle tracking. RESULTS: The in vitro study showed significantly less time needed for the simulated interventions in all examiners when V Nav was used (p<0.05. In the study involving patients, in all 10 biopsies of suspect lesions of the liver a histological confirmation was achieved. We also used V Nav for a breast biopsy (intraductal carcinoma, for a biopsy of the abdominal wall (metastasis of ovarial carcinoma and for radiofrequency ablations (4 ablations. In 8 cases of inflammatory abdominal lesions 9 percutaneous drainages were successfully inserted. CONCLUSION: Percutaneous biopsies and drainages, even of small lesions involving complex access pathways, can be accomplished with a high success rate by using 3D real time image fusion together with real time needle tracking.

  15. In vivo motion and force measurement of surgical needle intervention during prostate brachytherapy

    International Nuclear Information System (INIS)

    Podder, Tarun; Clark, Douglas; Sherman, Jason; Fuller, Dave; Messing, Edward; Rubens, Deborah; Strang, John; Brasacchio, Ralph; Liao, Lydia; Ng, W.-S.; Yu Yan

    2006-01-01

    In this paper, we present needle insertion forces and motion trajectories measured during actual brachytherapy needle insertion while implanting radioactive seeds in the prostate glands of 20 different patients. The needle motion was captured using ultrasound images and a 6 degree-of-freedom electromagnetic-based position sensor. Needle velocity was computed from the position information and the corresponding time stamps. From in vivo data we found the maximum needle insertion forces to be about 15.6 and 8.9 N for 17 gauge (1.47 mm) and 18 gauge (1.27 mm) needles, respectively. Part of this difference in insertion forces is due to the needle size difference (17G and 18G) and the other part is due to the difference in tissue properties that are specific to the individual patient. Some transverse forces were observed, which are attributed to several factors such as tissue heterogeneity, organ movement, human factors in surgery, and the interaction between the template and the needle. However, theses insertion forces are significantly responsible for needle deviation from the desired trajectory and target movement. Therefore, a proper selection of needle and modulated velocity (translational and rotational) may reduce the tissue deformation and target movement by reducing insertion forces and thereby improve the seed delivery accuracy. The knowledge gleaned from this study promises to be useful for not only designing mechanical/robotic systems but also developing a predictive deformation model of the prostate and real-time adaptive controlling of the needle

  16. Needle autopsy

    Directory of Open Access Journals (Sweden)

    Philip Davis Marsden

    1997-04-01

    Full Text Available Often in tropical practice there is not time or conditions to do a proper autopsy on a patient who has died. A needle biopsy technique is described for limited closed autopsy examination to clariffy organ histology. In this way the clinician may resolve puzzling fatal disease.Muitas vezes, em clínicas de países tropicais, não há tempo nem condições para se realizar uma necropsia adequada em um paciente que foi a óbito. Um técnica de biópsia por punção é descrita para fins de exame em necropsia limitadamente fechada, para esclarecimento da histologia do órgão. Dessa maneira, o clínico pode resolver enigmas de doenças fatais.

  17. Experimental insertions

    International Nuclear Information System (INIS)

    Sandweiss, J.; Kycia, T.F.

    1975-01-01

    A discussion is given of the eight identical experimental insertions for the planned ISABELLE storage rings. Four sets of quadrupole doublets are used to match the β functions in the insertions to the values in the cells, and the total free space available at the crossing point is 40 meters. An asymmetric beam energy operation is planned, which will be useful in a number of experiments

  18. Risk of needle stick injuries in health care workers: bad habits (recapping needles) last long.

    Science.gov (United States)

    Rogowska-Szadkowska, Dorota; Stanisławowicz, Małgorzata; Chlabicz, Sławomir

    2010-01-01

    In order to assess the nurses' knowledge concerning the risk of hepatitis B and C viruses or human immunodeficiency virus infection while performing their professional duties, an anonymous questionnaire developed by the authors was distributed in 2008. Surprisingly 64% respondents occasionally recapping needles after injections, although they know the procedures which are obligatory at the ward. The first step in preventing percutaneous injuries should focus on efforts to eliminate the practice of recapping needles, though education and convenient placement of puncture-resistant containers for the disposal of used sharps.

  19. A data-driven soft sensor for needle deflection in heterogeneous tissue using just-in-time modelling.

    Science.gov (United States)

    Rossa, Carlos; Lehmann, Thomas; Sloboda, Ronald; Usmani, Nawaid; Tavakoli, Mahdi

    2017-08-01

    Global modelling has traditionally been the approach taken to estimate needle deflection in soft tissue. In this paper, we propose a new method based on local data-driven modelling of needle deflection. External measurement of needle-tissue interactions is collected from several insertions in ex vivo tissue to form a cloud of data. Inputs to the system are the needle insertion depth, axial rotations, and the forces and torques measured at the needle base by a force sensor. When a new insertion is performed, the just-in-time learning method estimates the model outputs given the current inputs to the needle-tissue system and the historical database. The query is compared to every observation in the database and is given weights according to some similarity criteria. Only a subset of historical data that is most relevant to the query is selected and a local linear model is fit to the selected points to estimate the query output. The model outputs the 3D deflection of the needle tip and the needle insertion force. The proposed approach is validated in ex vivo multilayered biological tissue in different needle insertion scenarios. Experimental results in five different case studies indicate an accuracy in predicting needle deflection of 0.81 and 1.24 mm in the horizontal and vertical lanes, respectively, and an accuracy of 0.5 N in predicting the needle insertion force over 216 needle insertions.

  20. Percutaneous nephrostomy

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, In Hoon; Ryu, Kook Hyun; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun; Chung, Hyeon De [Chonnam National University College of Medicine, Chonju (Korea, Republic of)

    1990-12-15

    Percutaneous nephrostomy was performed in 82 patients under the fluoroscopic guidance for recent 3 years. The cause of hydronephrosis were as follows: unknown origin of stricture (N=37), stone (N=20), tumor (N=14), tuberculosis (N=8), postoperative ureteral injury (N=1), postoperative anastomotic stricture(N=1)and renal transplantation complication (N=1). Successful nephrostomy was achieved in 79 patients (96%). Causes if failure were minimal dilatation of pelvocaliceal system (N=2) and staghorn calculi (N=1). Follow up laboratory test shows high BUN and creatinine level returned to normal limit within 1 or 3 weeks in 73 patient. Major complication was not found, but temporary hematuria (N=4) or fever (N=1) was noted. In conclusion, percutaneous nephrostomy is the safe and effective method for the temporary and permanent relief of urinary obstruction and maintenance of ureteral patency.

  1. Percutaneous nephrostomy

    International Nuclear Information System (INIS)

    Ryu, In Hoon; Ryu, Kook Hyun; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun; Chung, Hyeon De

    1990-01-01

    Percutaneous nephrostomy was performed in 82 patients under the fluoroscopic guidance for recent 3 years. The cause of hydronephrosis were as follows: unknown origin of stricture (N=37), stone (N=20), tumor (N=14), tuberculosis (N=8), postoperative ureteral injury (N=1), postoperative anastomotic stricture(N=1)and renal transplantation complication (N=1). Successful nephrostomy was achieved in 79 patients (96%). Causes if failure were minimal dilatation of pelvocaliceal system (N=2) and staghorn calculi (N=1). Follow up laboratory test shows high BUN and creatinine level returned to normal limit within 1 or 3 weeks in 73 patient. Major complication was not found, but temporary hematuria (N=4) or fever (N=1) was noted. In conclusion, percutaneous nephrostomy is the safe and effective method for the temporary and permanent relief of urinary obstruction and maintenance of ureteral patency

  2. Safe percutaneous suprapubic catheterisation.

    Science.gov (United States)

    Goyal, N K; Goel, A; Sankhwar, S N

    2012-11-01

    We describe our technique of percutaneous suprapubic catheter insertion with special reference to steps that help to avoid common complications of haematuria and catheter misplacement. The procedure is performed using a stainless steel reusable trocar under local infiltrative anaesthesia, usually at the bedside. After clinical confirmation of a full bladder, the trocar is advanced into the bladder through a skin incision. Once the bladder is entered, the obturator is removed and the assistant inserts a Foley catheter followed by rapid balloon inflation. Slight traction is applied to the catheter for about five minutes. Patients with previous lower abdominal surgery, an inadequately distended bladder or acute pelvic trauma do not undergo suprapubic catheterisation using this method. The procedure was performed in 72 men (mean age: 42.4 years, range: 18-78 years) with urinary retention with a palpable bladder. The average duration of the procedure was less than five minutes. No complications were noted in any of the patients. Trocar suprapubic catheter insertion is a safe and effective bedside procedure for emergency bladder drainage and can be performed by resident surgeons. The common complications associated with the procedure can be avoided with a few careful steps.

  3. Laser Generated Leaky Acoustic Waves for Needle Visualization.

    Science.gov (United States)

    Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi

    2018-04-01

    Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.

  4. Percutaneous catheter drainage of intrapulmonary fluid collection

    International Nuclear Information System (INIS)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H.

    1994-01-01

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment

  5. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  6. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    International Nuclear Information System (INIS)

    Rossi, Umberto G.; Seitun, Sara; Ferro, Carlo

    2011-01-01

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.

  7. PVA matches human liver in needle-tissue interaction.

    Science.gov (United States)

    de Jong, Tonke L; Pluymen, Loes H; van Gerwen, Dennis J; Kleinrensink, Gert-Jan; Dankelman, Jenny; van den Dobbelsteen, John J

    2017-05-01

    Medical phantoms can be used to study needle-tissue interaction and to train medical residents. The purpose of this research is to study the suitability of polyvinyl alcohol (PVA) as a liver tissue mimicking material in terms of needle-tissue interaction. Insertions into ex-vivo human livers were used for reference. Six PVA samples were created by varying the mass percentage of PVA to water (4m% and 7m%) and the number of freeze-thaw cycles (1, 2 and 3 cycles, 16hours of freezing at -19°C, 8hours of thawing). The inner needle of an 18 Gauge trocar needle with triangular tip was inserted 13 times into each of the samples, using an insertion velocity of 5 mm/s. In addition, 39 insertions were performed in two ex-vivo human livers. Axial forces on the needle were captured during insertion and retraction and characterized by friction along the needle shaft, peak forces, and number of peak forces per unit length. The concentration of PVA and the number of freeze-thaw cycles both influenced the mechanical interaction between needle and specimen. Insertions into 4m% PVA phantoms with 2 freeze-thaw cycles were comparable to human liver in terms of estimated friction along the needle shaft and the number of peak forces. Therefore, these phantoms are considered to be suitable liver mimicking materials for image-guided needle interventions. The mechanical properties of PVA hydrogels can be influenced in a controlled manner by varying the concentration of PVA and the number of freeze-thaw cycles, to mimic liver tissue characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Directory of Open Access Journals (Sweden)

    Shaoli Liu

    Full Text Available The "robotic-assisted liver tumor coagulation therapy" (RALTCT system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1 multiple needles are needed to destroy the entire tumor, (2 the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3 the placement of multiple needles should avoid interference with each other, (4 an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5 the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW, which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor

  9. Automatic Multiple-Needle Surgical Planning of Robotic-Assisted Microwave Coagulation in Large Liver Tumor Therapy.

    Science.gov (United States)

    Liu, Shaoli; Xia, Zeyang; Liu, Jianhua; Xu, Jing; Ren, He; Lu, Tong; Yang, Xiangdong

    2016-01-01

    The "robotic-assisted liver tumor coagulation therapy" (RALTCT) system is a promising candidate for large liver tumor treatment in terms of accuracy and speed. A prerequisite for effective therapy is accurate surgical planning. However, it is difficult for the surgeon to perform surgical planning manually due to the difficulties associated with robot-assisted large liver tumor therapy. These main difficulties include the following aspects: (1) multiple needles are needed to destroy the entire tumor, (2) the insertion trajectories of the needles should avoid the ribs, blood vessels, and other tissues and organs in the abdominal cavity, (3) the placement of multiple needles should avoid interference with each other, (4) an inserted needle will cause some deformation of liver, which will result in changes in subsequently inserted needles' operating environment, and (5) the multiple needle-insertion trajectories should be consistent with the needle-driven robot's movement characteristics. Thus, an effective multiple-needle surgical planning procedure is needed. To overcome these problems, we present an automatic multiple-needle surgical planning of optimal insertion trajectories to the targets, based on a mathematical description of all relevant structure surfaces. The method determines the analytical expression of boundaries of every needle "collision-free reachable workspace" (CFRW), which are the feasible insertion zones based on several constraints. Then, the optimal needle insertion trajectory within the optimization criteria will be chosen in the needle CFRW automatically. Also, the results can be visualized with our navigation system. In the simulation experiment, three needle-insertion trajectories were obtained successfully. In the in vitro experiment, the robot successfully achieved insertion of multiple needles. The proposed automatic multiple-needle surgical planning can improve the efficiency and safety of robot-assisted large liver tumor therapy

  10. CT-guided percutaneous treatment of solitary pyogenic splenic abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Pombo, F. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Suarez, I. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Marini, M. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Arrojo, L. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Echaniz, A. [Dept. of Internal Medicine, Hospital Juan Canalejo, La Coruna (Spain)

    1991-08-01

    Six patients with solitary pyogenic splenic abscesses treated by CT-guided percutaneous drainage (by catheter or needle), are presented. There were 3 unilocular, purely intrasplenic abscesses and 3 complex lesions with loculations and perisplenic involvement. Percutaneous drainage and intravenous antibiotics were curative in 4 patients. In the other 2, who had multiloculated abscesses, despite initially successful drainage, splenectomy was performed because of intractable left upper quadrant pain in one case and persistent fever and drainage of pus after 30 days in the other. These patients also developed large, sterile left pleural effusions. Solitary pyogenic splenic abscesses - particularly if uniloculated - can be effectively treated by CT-guided percutaneous drainage. (orig.)

  11. Percutaneous endoscopic gastrostomy.

    Science.gov (United States)

    Gay, F; el Nawar, A; Van Gossum, A

    1992-01-01

    From March 87 to March 92, fifty eight patients were referred to our department for percutaneous endoscopic gastrostomy (PEG). The modality of the feeding tube insertion is described. The most common indications for placement were neurologic disorders in 62% of the cases (n = 36) and malignant diseases in 32% (n = 19). The success rate of the technique was 98.3% (n = 57). No procedure-related mortality was observed. A low rate of major complication (1.7%) and minor complication (10.5%) was noted. Feeding tubes were removed in 21% of patients (n = 12); none of them with malignant disease. Survival curve analysis demonstrated that 50% of patients died within 3 months of PEG placement. Such results raise questions about the selection of patients undergoing PEG. Our experience of patients undergoing PEG. Our experience suggests that PEG is easy and safe, even in debilitated patients, having an acceptable life expectancy.

  12. Experimental model of intervertebral disc degeneration by needle puncture in Wistar rats

    Energy Technology Data Exchange (ETDEWEB)

    Issy, A.C.; Castania, V.; Castania, M. [Departamento de Morfologia, Fisiologia e Patologia Básica, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Salmon, C.E.G. [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Nogueira-Barbosa, M.H. [Divisão de Radiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Bel, E. Del [Departamento de Morfologia, Fisiologia e Patologia Básica, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Defino, H.L.A. [Departamento de Biomecânica, Medicina e Reabilitação do Sistema Locomotor, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-03-15

    Animal models of intervertebral disc degeneration play an important role in clarifying the physiopathological mechanisms and testing novel therapeutic strategies. The objective of the present study is to describe a simple animal model of disc degeneration involving Wistar rats to be used for research studies. Disc degeneration was confirmed and classified by radiography, magnetic resonance and histological evaluation. Adult male Wistar rats were anesthetized and submitted to percutaneous disc puncture with a 20-gauge needle on levels 6-7 and 8-9 of the coccygeal vertebrae. The needle was inserted into the discs guided by fluoroscopy and its tip was positioned crossing the nucleus pulposus up to the contralateral annulus fibrosus, rotated 360° twice, and held for 30 s. To grade the severity of intervertebral disc degeneration, we measured the intervertebral disc height from radiographic images 7 and 30 days after the injury, and the signal intensity T2-weighted magnetic resonance imaging. Histological analysis was performed with hematoxylin-eosin and collagen fiber orientation using picrosirius red staining and polarized light microscopy. Imaging and histological score analyses revealed significant disc degeneration both 7 and 30 days after the lesion, without deaths or systemic complications. Interobserver histological evaluation showed significant agreement. There was a significant positive correlation between histological score and intervertebral disc height 7 and 30 days after the lesion. We conclude that the tail disc puncture method using Wistar rats is a simple, cost-effective and reproducible model for inducing disc degeneration.

  13. Experimental model of intervertebral disc degeneration by needle puncture in Wistar rats

    International Nuclear Information System (INIS)

    Issy, A.C.; Castania, V.; Castania, M.; Salmon, C.E.G.; Nogueira-Barbosa, M.H.; Bel, E. Del; Defino, H.L.A.

    2013-01-01

    Animal models of intervertebral disc degeneration play an important role in clarifying the physiopathological mechanisms and testing novel therapeutic strategies. The objective of the present study is to describe a simple animal model of disc degeneration involving Wistar rats to be used for research studies. Disc degeneration was confirmed and classified by radiography, magnetic resonance and histological evaluation. Adult male Wistar rats were anesthetized and submitted to percutaneous disc puncture with a 20-gauge needle on levels 6-7 and 8-9 of the coccygeal vertebrae. The needle was inserted into the discs guided by fluoroscopy and its tip was positioned crossing the nucleus pulposus up to the contralateral annulus fibrosus, rotated 360° twice, and held for 30 s. To grade the severity of intervertebral disc degeneration, we measured the intervertebral disc height from radiographic images 7 and 30 days after the injury, and the signal intensity T2-weighted magnetic resonance imaging. Histological analysis was performed with hematoxylin-eosin and collagen fiber orientation using picrosirius red staining and polarized light microscopy. Imaging and histological score analyses revealed significant disc degeneration both 7 and 30 days after the lesion, without deaths or systemic complications. Interobserver histological evaluation showed significant agreement. There was a significant positive correlation between histological score and intervertebral disc height 7 and 30 days after the lesion. We conclude that the tail disc puncture method using Wistar rats is a simple, cost-effective and reproducible model for inducing disc degeneration

  14. Temperature Measurement During Polymerization of Bone Cement in Percutaneous Vertebroplasty: An In Vivo Study in Humans

    International Nuclear Information System (INIS)

    Anselmetti, Giovanni Carlo; Manca, Antonio; Kanika, Khanna; Murphy, Kieran; Eminefendic, Haris; Masala, Salvatore; Regge, Daniele

    2009-01-01

    Aim of the study was to 'in vivo' measure temperature, during percutaneous vertebroplasty (PV), within a vertebral body injected with different bone cements. According to the declaration of Helsinki, 22 women (60-80 years; mean, 75 years) with painful osteoporotic vertebral collapse underwent bilateral transpedicular PV on 22 lumbar vertebrae. Two 10-G vertebroplasty needles were introduced into the vertebra under digital fluoroscopy; a 16-G radiofrequency thermoablation needle (Starburst XL; RITA Medical System Inc., USA), carrying five thermocouples, was than coaxially inserted. Eleven different bone cements were injected and temperatures were measured every 30 s until temperatures dropped under 45 o C. After the thermocouple needle was withdrawn, bilateral PV was completed with cement injection through the vertebroplasty needle. Unpaired Student's t-tests, Kruskal-Wallis test, and Wilcoxon signed rank test were used to evaluate significant differences (p o C), B (from 50 o to 60 o C), and C (below 50 o C). Peak temperature in Group A (86.7 ± 10.7 o C) was significantly higher (p = 0.0172) than that in Groups B (60.5 ± 3.7 o C) and C (44.8 ± 2.6 o C). The average of all thermocouples showed an extremely significant difference (p = 0.0002) between groups. None of the tested cements maintained a temperature ≥45 o C for more than 30 min. These data suggest that back-pain improvement is obtained not by thermal necrosis but by mechanical consolidation only. The relative necrotic thermal effect in vertebral metastases seems to confirm that analgesia must be considered the main intent of PV.

  15. It is time for a better clip applier - 3 mm, percutaneous, non-crushing and locking.

    Science.gov (United States)

    Yuval, Jonathan B; Weiss, Daniel J; Paz, Adrian; Bachar, Yehuda; Brodie, Ronit; Shapira, Yinon; Mintz, Yoav

    2017-10-06

    Since the advent of laparoscopy there have been attempts to minimize abdominal wall incisions. For this purpose smaller instruments have been produced. Our aim was to develop the first 3 mm percutaneous clip applier and to make it better than the standard clips of today. The ClipTip clip is made of Nitinol and has a crocodile shaped jaws, which when apposed effectively seal vessels. The shaft operates as a retractable needle permitting percutaneous insertion. Closing, reopening and reclosing is possible. The physical properties of the device were compared to three commercially available clip appliers. Surgeries were performed on porcine animals by experienced surgeons. In comparison to available clips, the superiority of the ClipTip is a combination of wide effective length alongside the ability to withstand strong forces. In live animal studies the Cliptip was inserted into the peritoneal cavity without any injuries. Vessels were ligated successfully and no clip dislodgement or leakage occurred. We developed the next generation clip applier with better properties. Advantages include its length, the needleoscopic caliber, non-crushing effect, locking mechanism and wide aperture. The device has performed safely and effectively in pre-clinical tests. Further studies are planned in humans.

  16. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  17. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  18. Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Qing-Hua, E-mail: ddqinghua-tian@163.com; He, Cheng-Jian, E-mail: tianhechengjian@163.com; Wu, Chun-Gen, E-mail: 649514608@qq.com; Li, Yong-Dong, E-mail: tianliyongdong@163.com; Gu, Yi-Feng, E-mail: tianyifenggu@163.com; Wang, Tao, E-mail: tianandwangtao@163.com; Xiao, Quan-Ping, E-mail: tianxiaoquanping@163.com; Li, Ming-Hua, E-mail: tianminghuali@163.com [Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Department of Diagnostic and Interventional Radiology (China)

    2016-01-15

    PurposeTo compare the efficacy of percutaneous cementoplasty (PCP) with and without interventional internal fixation (IIF) on malignant impending pathological fracture of proximal femur.MethodsA total of 40 patients with malignant impending pathological fracture of proximal femur were selected for PCP and IIF (n = 19, group A) or PCP alone (n = 21, group B) in this non-randomized prospective study. Bone puncture needles were inserted into the proximal femur, followed by sequential installation of the modified trocar inner needles through the puncture needle sheath. Then, 15–45 ml cement was injected into the femur lesion.ResultsThe overall excellent and good pain relief rate during follow-ups were significantly higher in group A than that in group B (89 vs. 57 %, P = 0.034). The average change of VAS, ODI, KPS, and EFES in group A were significantly higher than those in group B at 1-, 3-, 6-month, 1-year (P < 0.05). Meanwhile, The stability of the treated femur was significantly higher in group A than that in group B (P < 0.05).ConclusionPCP and IIF were not only a safe and effective procedure, but resulted in greater pain relief, bone consolidation, and also reduced the risk of fracture than the currently recommended approach of PCP done on malignant proximal femoral tumor.

  19. Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur

    International Nuclear Information System (INIS)

    Tian, Qing-Hua; He, Cheng-Jian; Wu, Chun-Gen; Li, Yong-Dong; Gu, Yi-Feng; Wang, Tao; Xiao, Quan-Ping; Li, Ming-Hua

    2016-01-01

    PurposeTo compare the efficacy of percutaneous cementoplasty (PCP) with and without interventional internal fixation (IIF) on malignant impending pathological fracture of proximal femur.MethodsA total of 40 patients with malignant impending pathological fracture of proximal femur were selected for PCP and IIF (n = 19, group A) or PCP alone (n = 21, group B) in this non-randomized prospective study. Bone puncture needles were inserted into the proximal femur, followed by sequential installation of the modified trocar inner needles through the puncture needle sheath. Then, 15–45 ml cement was injected into the femur lesion.ResultsThe overall excellent and good pain relief rate during follow-ups were significantly higher in group A than that in group B (89 vs. 57 %, P = 0.034). The average change of VAS, ODI, KPS, and EFES in group A were significantly higher than those in group B at 1-, 3-, 6-month, 1-year (P < 0.05). Meanwhile, The stability of the treated femur was significantly higher in group A than that in group B (P < 0.05).ConclusionPCP and IIF were not only a safe and effective procedure, but resulted in greater pain relief, bone consolidation, and also reduced the risk of fracture than the currently recommended approach of PCP done on malignant proximal femoral tumor

  20. Effect of bidirectional rotation of an acupuncture needle at LI10 on acupuncture needle sensation and experimentally-induced contact heat pain in healthy human volunteers.

    Science.gov (United States)

    Benham, Alex; Johnson, Mark I

    2014-06-01

    There is insufficient evidence of a relationship between acupuncture needle sensations (de qi) and hypoalgesia. The aim of this study was to investigate the effects of bidirectional needle rotation at LI10 on acupuncture needle sensations and heat pain thresholds. Twenty-two healthy participants received one acupuncture needle at LI10 with bidirectional rotation of the needle in one experimental session and one acupuncture needle at LI10 with mock rotation in a separate session, in a randomised order. Measurements of heat pain thresholds were taken before needle insertion, during needle retention and 15 min after needle removal. At each measurement time point, participants rated needle sensations using the Massachusetts Acupuncture Sensation Scale (MASS) and a visual analogue scale (VAS) of overall intensity of needle sensation. Bidirectional needle rotation produced significantly higher scores for VAS, MASStotal, MASSpain and MASSsensation compared with mock rotation (all psensation and change in pain threshold after needling was only found when data from mock and rotation interventions were combined. Needle rotation increases the magnitude of hypoalgesia. There is tentative evidence that needle sensation may be associated with the amount of change in pain threshold. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Thyroid tissue: US-guided percutaneous laser thermal ablation.

    Science.gov (United States)

    Pacella, Claudio Maurizio; Bizzarri, Giancarlo; Spiezia, Stefano; Bianchini, Antonio; Guglielmi, Rinaldo; Crescenzi, Anna; Pacella, Sara; Toscano, Vincenzo; Papini, Enrico

    2004-07-01

    To evaluate in vivo the safety and effectiveness of percutaneous laser thermal ablation (LTA) in the debulking of thyroid lesions. Twenty-five adult patients at poor surgical risk with cold nodules (n = 8), autonomously hyperfunctioning thyroid nodules (n = 16), or anaplastic carcinoma (n = 1) underwent LTA. One to four 21-gauge spinal needles were inserted with ultrasonographic (US) guidance into the thyroid lesions. A 300-microm-diameter quartz optical fiber was advanced through the sheath of the needle. Nd:YAG laser was used with output power of 3-5 W. Side effects, complications, and clinical and hormonal changes were evaluated at the end of LTA and during follow-up. Linear regression analysis was used to investigate the correlation between energy delivered and reduction in nodule volume. Volume of induced necrosis and reduction in nodule volume were assessed with US or computed tomography. LTA was performed without difficulties in 76 LTA sessions. After treatment with 5 W, two patients experienced mild dysphonia, which resolved after 48 hours and 2 months. Improvement of local compression symptoms was experienced by 12 of 14 (86%) patients. Thyroid-stimulating hormone (TSH) was detectable in five of 16 (31%) patients with hyperfunctioning nodules at 6 months after LTA. Volume of induced necrosis ranged from 0.8 to 3.9 mL per session. Anaplastic carcinoma treated with four fibers yielded 32.0 mL of necrosis. Echo structure and baseline volume did not influence response. Energy load and reduction in nodule volume were significantly correlated (r(2) =.75, P nodule volume reduction at 6 months in hyperfunctioning nodules was 3.3 mL +/- 2.8 (62% +/- 21.4 [SD]) and in cold nodules was 7.7 mL +/- 7.5 (63% +/- 13.8). LTA may be a therapeutic tool for highly selected problems in the treatment of thyroid lesions. Copyright RSNA, 2004

  2. Percutaneous cholecystostomy

    International Nuclear Information System (INIS)

    Akhan, Okan; Akinci, Devrim; Oezmen, Mustafa N.

    2002-01-01

    Percutaneous cholecystostomy (PC), a technique that consists of percutaneous catheter placement in the gallbladder lumen under imaging guidance, has become an alternative to surgical cholecystostomy in recent years. Indications of PC include calculous or acalculous cholecystitis, cholangitis, biliary obstruction and opacification of biliary ducts. It also provides a potential route for stone dissolution therapy and stone extraction. Under aseptic conditions and ultrasound guidance, using local anesthesia, the procedure is carried out by using either modified Seldinger technique or trocar technique. Transhepatic or transperitoneal puncture can be performed as an access route. Several days after the procedure transcatheter cholangiography is performed to assess the patency of cystic duct, presence of gallstones and catheter position. The tract is considered mature in the absence of leakage to the peritoneal cavity, subhepatic, subcapsular, or subdiaphragmatic spaces. Response rates to PC in the literature are between the range of 56-100% as the variation of different patient population. Complications associated with PC usually occur immediately or within days and include haemorrhage, vagal reactions, sepsis, bile peritonitis, pneumothorax, perforation of the intestinal loop, secondary infection or colonisation of the gallbladder and catheter dislodgment. Late complications have been reported as catheter dislodgment and recurrent cholecystitis. PC under ultrasonographic guidance is a cost-effective, easy to perform and reliable procedure with low complication and high success rates for critically ill patients with acute cholecystitis. It is generally followed by elective cholecystectomy, if possible. However, it may be definitive treatment, especially in acalculous cholecystitis

  3. Percutaneous cholecystostomy

    Energy Technology Data Exchange (ETDEWEB)

    Akhan, Okan E-mail: akhano@tr.net; Akinci, Devrim; Oezmen, Mustafa N

    2002-09-01

    Percutaneous cholecystostomy (PC), a technique that consists of percutaneous catheter placement in the gallbladder lumen under imaging guidance, has become an alternative to surgical cholecystostomy in recent years. Indications of PC include calculous or acalculous cholecystitis, cholangitis, biliary obstruction and opacification of biliary ducts. It also provides a potential route for stone dissolution therapy and stone extraction. Under aseptic conditions and ultrasound guidance, using local anesthesia, the procedure is carried out by using either modified Seldinger technique or trocar technique. Transhepatic or transperitoneal puncture can be performed as an access route. Several days after the procedure transcatheter cholangiography is performed to assess the patency of cystic duct, presence of gallstones and catheter position. The tract is considered mature in the absence of leakage to the peritoneal cavity, subhepatic, subcapsular, or subdiaphragmatic spaces. Response rates to PC in the literature are between the range of 56-100% as the variation of different patient population. Complications associated with PC usually occur immediately or within days and include haemorrhage, vagal reactions, sepsis, bile peritonitis, pneumothorax, perforation of the intestinal loop, secondary infection or colonisation of the gallbladder and catheter dislodgment. Late complications have been reported as catheter dislodgment and recurrent cholecystitis. PC under ultrasonographic guidance is a cost-effective, easy to perform and reliable procedure with low complication and high success rates for critically ill patients with acute cholecystitis. It is generally followed by elective cholecystectomy, if possible. However, it may be definitive treatment, especially in acalculous cholecystitis.

  4. 3-Dimensional printing guide template assisted percutaneous vertebroplasty: Technical note.

    Science.gov (United States)

    Li, Jian; Lin, JiSheng; Yang, Yong; Xu, JunChuan; Fei, Qi

    2018-06-01

    Percutaneous vertebroplasty (PVP) is currently considered as an effective treatment for pain caused by acute osteoporotic vertebral compression fracture. Recently, puncture-related complications are increasingly reported. It's important to find a precise technique to reduce the puncture-related complications. We report a case and discussed the novel surgical technique with step-by-step operating procedures, to introduce the precise PVP assisted by a 3-dimensional printing guide template. Based on the preoperative CT scan and infrared scan data, a well-designed individual guide template could be established in a 3-dimensional reconstruction software and printed out by a 3-dimensional printer. In real operation, by matching the guide template to patient's back skin, cement needles' insertion orientation and depth were easily established. Only 14 times C-arm fluoroscopy with HDF mode (total exposure dose was 4.5 mSv) were required during the procedure. The operation took only 17 min. Cement distribution in the vertebral body was very good without any puncture-related complications. Pain was significantly relieved after surgery. In conclusion, the novel precise 3-dimensional printing guide template system may allow (1) comprehensive visualization of the fractured vertebral body and the individual surgical planning, (2) the perfect fitting between skin and guide template to ensure the puncture stability and accuracy, and (3) increased puncture precision and decreased puncture-related complications, surgical time and radiation exposure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Percutaneous laser ablation of hepatocellular carcinoma in patients with liver cirrhosis awaiting liver transplantation

    International Nuclear Information System (INIS)

    Pompili, Maurizio; Pacella, Claudio Maurizio; Francica, Giampiero; Angelico, Mario; Tisone, Giuseppe; Craboledda, Paolo; Nicolardi, Erica; Rapaccini, Gian Ludovico; Gasbarrini, Giovanni

    2010-01-01

    Objective: The aim of this study was to determine the effectiveness and safety of percutaneous laser ablation for the treatment of cirrhotic patients with hepatocellular carcinoma awaiting liver transplantation. Materials and methods: The data of 9 male cirrhotic patients (mean age 50 years, range 45-60 years) with 12 biopsy proven nodules of hepatocellular carcinoma (mean diameter 2.0 cm, range 1.0-3.0 cm) treated by laser ablation before liver transplantation between June 2000 and January 2006 were retrospectively reviewed. Laser ablation was carried out by inserting 300 nm optical fibers through 21-Gauge needles (from two to four) positioned under ultrasound guidance into the target lesions. A continuous wave Neodymium:Yttrium Aluminium Garnet laser was used. Transarterial chemoembolization prior to liver transplantation was performed in two incompletely ablated tumors. Results: No procedure-related major complications were recorded. During the waiting time to liver transplantation local tumor progression after ablation occurred in 3 nodules (25%). At histological examination of the explanted livers complete necrosis was found in 8 nodules (66.7%, all treated exclusively with laser ablation), partial necrosis >50% in 3 nodules (25%), and partial necrosis <50% in 1 nodule. Conclusion: In patients with cirrhotic livers awaiting liver transplantation, percutaneous laser ablation is safe and effective for the management of small hepatocellular carcinoma.

  6. CT‑guided percutaneous transthoracic lung biopsy: First experience ...

    African Journals Online (AJOL)

    Percutaneous lung biopsy had been described in the nineteenth century by Leyden, but image- guided needle chest biopsy only gained widespread acceptance in the 1970s. Currently, tissue sampling of a thoracic lesion is indicated when the diagnosis cannot be obtained by the non-invasive techniques and cytological ...

  7. Amoebic liver abscess: Drained by ultrasound guided percutaneous ...

    African Journals Online (AJOL)

    Summary: Amoebic Liver Abscess in a 20-month-old child: A case of amoebic liver abscess in a Nigerian child is presented. Management consisted of 10days course of Metronidazole and 5days course of Tinidazole without improvement. This was followed by four sessions of ultrasound guided percutaneous needle ...

  8. DupuytrEn Treatment EffeCtiveness Trial (DETECT): a protocol for prospective, randomised, controlled, outcome assessor-blinded, three-armed parallel 1:1:1, multicentre trial comparing the effectiveness and cost of collagenase clostridium histolyticum, percutaneous needle fasciotomy and limited fasciectomy as short-term and long-term treatment strategies in Dupuytren's contracture.

    Science.gov (United States)

    Räisänen, Mikko P; Karjalainen, Teemu; Göransson, Harry; Reito, Aleksi; Kautiainen, Hannu; Malmivaara, Antti; Leppänen, Olli V

    2018-03-28

    Dupuytren's contracture (DC) is a chronic fibroproliferative disorder of the palmar fascia which leads to flexion contracture in one or more fingers. There is no definitive cure for DC, and treatment aims at relieving symptoms by releasing the contracture using percutaneous or operative techniques. We planned a prospective, randomised, controlled, outcome assessor-blinded, three-armed parallel 1:1:1, multicentre trial comparing the effectiveness and cost of (1) collagenase clostridium histolyticum injection followed by limited fasciectomy in non-responsive cases, (2) percutaneous needle fasciotomy followed by limited fasciectomy in non-responsive cases and (3) primary limited fasciectomy during short-term and long-term follow-up for Tubiana I-III stages DC. We will recruit participants from seven national centres in Finland. Primary outcome is the rate of success in the treatment arm at 5 years after recruitment. Success is a composite outcome comprising (1) at least 50% contracture release from the date of recruitment and (2) participants in a patient-accepted symptom state (PASS). Secondary outcomes are (1) angle of contracture, (2) quick disabilities of the arm, a shoulder and hand outcome measure (QuickDASH), (3) perceived hand function, (4) EQ-5D-3L, (5) rate of major adverse events, (6) patient's trust of the treatment, (7) global rating, (8) rate of PASS, (9) rate of minimal clinically important improvement, (10) expenses, (11) progression of disease, (12) progression-free survival, (13) favoured treatment modality, (14) patients achieving full contracture release and >50% improvement and (15) patient satisfaction with the treatment effect. Predictive factors for achieving the PASS will also be analysed. The protocol was approved by the Tampere University Hospital Institutional Review Board and Finnish Medicine Agency. The study will be performed according to the principles of good clinical practice. The results of the trial will be disseminated as

  9. Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy

    International Nuclear Information System (INIS)

    Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    An algorithm was developed in order to segment and track brachytherapy needles inserted along oblique trajectories. Three-dimensional (3D) transrectal ultrasound (TRUS) images of the rigid rod simulating the needle inserted into the tissue-mimicking agar and chicken breast phantoms were obtained to test the accuracy of the algorithm under ideal conditions. Because the robot possesses high positioning and angulation accuracies, we used the robot as a ''gold standard,'' and compared the results of algorithm segmentation to the values measured by the robot. Our testing results showed that the accuracy of the needle segmentation algorithm depends on the needle insertion distance into the 3D TRUS image and the angulations with respect to the TRUS transducer, e.g., at a 10 deg. insertion anglulation in agar phantoms, the error of the algorithm in determining the needle tip position was less than 1 mm when the insertion distance was greater than 15 mm. Near real-time needle tracking was achieved by scanning a small volume containing the needle. Our tests also showed that, the segmentation time was less than 60 ms, and the scanning time was less than 1.2 s, when the insertion distance into the 3D TRUS image was less than 55 mm. In our needle tracking tests in chicken breast phantoms, the errors in determining the needle orientation were less than 2 deg. in robot yaw and 0.7 deg. in robot pitch orientations, for up to 20 deg. needle insertion angles with the TRUS transducer in the horizontal plane when the needle insertion distance was greater than 15 mm

  10. Use of a Puncture Needle for Recanalization of an Occluded Right Subclavian Vein

    International Nuclear Information System (INIS)

    Gupta, Himanshu; Murphy, Timothy P.; Soares, Gregory M.

    1998-01-01

    We report a patient in whom we used a puncture needle to initiate percutaneous recanalization of a chronic occlusion of the junction between the right subclavian vein and the right brachiocephalic vein. Under fluoroscopic guidance, an 18-gauge needle was used to puncture the right subclavian vein. When contrast material injected through the needle confirmed intravascular location, the needle was advanced until it deflected and perforated an occlusion balloon target positioned within the right brachiocephalic vein. This technique may be useful in patients with central venous occlusions that are refractory to traversal using traditional catheter and guidewire techniques

  11. Percutaneous Tracheostomy

    Science.gov (United States)

    Mehta, Chitra; Mehta, Yatin

    2017-01-01

    Percutaneous dilatational tracheostomy (PDT) is a commonly performed procedure in critically sick patients. It can be safely performed bedside by intensivists. This has resulted in decline in the use of surgical tracheostomy in intensive care unit (ICU) except in few selected cases. Most common indication of tracheostomy in ICU is need for prolonged ventilation. About 10% of patients requiring at least 3 days of mechanical ventilator support get tracheostomised during ICU stay. The ideal timing of PDT remains undecided at present. Contraindications and complications become fewer with increase in experience. Various methods of performing PDT have been discovered in last two decades. Preoperative work up, patient selection and post tracheostomy care form key components of a successful PDT. Bronchoscopy and ultrasound have been found to be useful procedural adjuncts, especially in presence of unfavorable anatomy. This article gives a brief overview about the use of PDT in ICU. PMID:28074819

  12. Percutaneous gastroenterostomy

    Energy Technology Data Exchange (ETDEWEB)

    Wittich, G.R.; Van Sonnenberg, E.; Casola, G.; Jantsch, H.; Walter, R.; Lechner, G.

    1987-05-01

    Percutaneous gastrostomies or gastroenterostomies serve for temporary or permanent enteric feeding in patients with obstruction or functional derangement of the esophagus or hypopharynx. In addition, this radiological procedure may be indicated for small bowel decompression. The authors present their experience in 71 patients. Insufflation of air through a nasogastric tube or catheter is the preferred method for gastric distension. The inferior margin of the left lobe of the liver and the transverse colon are localized sonographically and fluoroscopically prior to puncture. Either Seldinger or Trocartechniques have proven effective in establishing access to the stomach. The feeding tube is advanced into the proximal jejunum to reduce the likelyhood of gastroesophageal reflux and possible aspiration. Complications were encountered in four patients and included catheter dislocation in three and respiratory distress in one patient.

  13. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  14. Percutaneous drainage of lung abscesses

    International Nuclear Information System (INIS)

    van Sonnenberg, E.; D'Agostino, H.; Casola, G.; Vatney, R.R.; Wittich, G.R.; Harker, C.

    1989-01-01

    The authors performed percutaneous drainage of lung abscesses in 12 patients. Indications for drainage were septicemia and persistence or worsening of radiographic findings. These lung abscesses were refractory to intravenous antibiotics and to bronchial toilet. Etiology of the abscesses included pneumonia (most frequently), trauma, postoperative development, infected necrotic neoplasm, and infected sequestration. Guidelines for drainage included passage of the catheter through contiguously abnormal lung and pleura, inability of the patient to cough, and/or bronchial obstruction precluding bronchial drainage. Cure was achieved in 11 of 12 patients. Catheters were removed on an average of 16 days after insertion. Antibiotics were administered an average of 18 days before drainage. No major complications occurred

  15. Percutaneous placement of ureteral stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hyup; Park, Jae Hyung; Han, Joon Koo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Antegrade placement of ureteral stents has successfully achieved in 41 of 46 ureters. When it was difficult to advance ureteral stents through the lesion, it was facilitated by retrograde guide-wire snare technique through urethra. Complications associated with the procedure were non-function of ureteral stent by occlusion, upward migration,and spontaneous fracture of ureteral stent. These complications were managed by percutaneous nephrostomy and removal of ureteral stents by guide-wire snare technique and insertion of a new ureteral stent. While blood cell in urine was markedly increased in about 50% of patients following the procedure.

  16. Tips and Tricks of Percutaneous Gastrostomy Under Image Guidance in Patients with Limited Access

    Energy Technology Data Exchange (ETDEWEB)

    Marcy, Pierre-Yves; Figl, Andrea; Thariat, Juliette [Sophia Antipolis University, Nice cedex (France); Lacout, Alexis [Centre Me' dico-Chirurgical, Aurillac (France)

    2011-10-15

    -gastrectomized patients who were contraindicated for endoscopic gastrostomy (2). Another condition precluding the traditional supracolic approach is the Chilaiditi sign, i.e. a usually asymptomatic interposition of the colon between liver and diaphragm. This condition may occur in patients with dolichocolon, chronic lung disease, cirrhosis, as well as ascites and right hemi-diaphragm palsy. Colonic opacification should always be performed prior to a gastrostomy to prevent the potential risk of gastrocolic fistula. Colonic opacification can be achieved using air inflation when starting a gastrostomy (1) or barium swallow 12 hours prior. We and others perform PFG using an uncomplicated controlled percutaneous gastropexy below the transverse mesocolon (2,4). The PFG tract is made centrally on the gastropexy using a true right-angle 18G-needle to the skin surface, a 0.0038-inch Amplatz guidewire and serial dilators following cutaneous anesthesia down to peritoneum with 40 ml of 1% Lidocaine chlorhydrate. The needle (N) traverses the greater omentum (GO), transverse mesocolon (TM), gastrocolic ligament (GCL), and lesser sac (between TM and GCL). Four anchor hooks were then inserted with limited pressure, and a 17-Fr catheter subsequently placed through a peel-away sheath inside the stomach and below the transverse colon (Fig. 1). We noted that GO is known as the so-called 'abdominal policeman' because it wraps itself around an inflamed organ thereby protecting other viscera from it. Literature data on infracolic PFG insertion are scarce (4): less than ten (uncomplicated) cases have been performed worldwide. The real contraindication of infracolic PFG includes hypopharyngeal/cervical esophageal neoplasia since the gastropexy precludes any further pull-up technique attempt. In conclusion, contraindications for endoscopic gastrostomy include UDTO and Chilaiditi sign. We suggest that the fluoroscopy-guided gastrostomy Chan's technique can be improved using effervescent sodium

  17. Tips and Tricks of Percutaneous Gastrostomy Under Image Guidance in Patients with Limited Access

    International Nuclear Information System (INIS)

    Marcy, Pierre-Yves; Figl, Andrea; Thariat, Juliette; Lacout, Alexis

    2011-01-01

    -gastrectomized patients who were contraindicated for endoscopic gastrostomy (2). Another condition precluding the traditional supracolic approach is the Chilaiditi sign, i.e. a usually asymptomatic interposition of the colon between liver and diaphragm. This condition may occur in patients with dolichocolon, chronic lung disease, cirrhosis, as well as ascites and right hemi-diaphragm palsy. Colonic opacification should always be performed prior to a gastrostomy to prevent the potential risk of gastrocolic fistula. Colonic opacification can be achieved using air inflation when starting a gastrostomy (1) or barium swallow 12 hours prior. We and others perform PFG using an uncomplicated controlled percutaneous gastropexy below the transverse mesocolon (2,4). The PFG tract is made centrally on the gastropexy using a true right-angle 18G-needle to the skin surface, a 0.0038-inch Amplatz guidewire and serial dilators following cutaneous anesthesia down to peritoneum with 40 ml of 1% Lidocaine chlorhydrate. The needle (N) traverses the greater omentum (GO), transverse mesocolon (TM), gastrocolic ligament (GCL), and lesser sac (between TM and GCL). Four anchor hooks were then inserted with limited pressure, and a 17-Fr catheter subsequently placed through a peel-away sheath inside the stomach and below the transverse colon (Fig. 1). We noted that GO is known as the so-called 'abdominal policeman' because it wraps itself around an inflamed organ thereby protecting other viscera from it. Literature data on infracolic PFG insertion are scarce (4): less than ten (uncomplicated) cases have been performed worldwide. The real contraindication of infracolic PFG includes hypopharyngeal/cervical esophageal neoplasia since the gastropexy precludes any further pull-up technique attempt. In conclusion, contraindications for endoscopic gastrostomy include UDTO and Chilaiditi sign. We suggest that the fluoroscopy-guided gastrostomy Chan's technique can be improved using effervescent sodium bicarbonate powder

  18. High-Field MRI-Compatible Needle Placement Robot for Prostate Interventions

    Science.gov (United States)

    SU, Hao; CAMILO, Alex; COLE, Gregory A.; HATA, Nobuhiko; TEMPANY, Clare M.; FISCHER, Gregory S.

    2014-01-01

    This paper presents the design of a magnetic resonance imaging (MRI) compatible needle placement system actuated by piezoelectric actuators for prostate brachytherapy and biopsy. An MRI-compatible modular 3 degree-of-freedom (DOF) needle driver module coupled with a 3-DOF x-y-z stage is proposed as a slave robot to precisely deliver radioactive brachytherapy seeds under interactive MRI guidance. The needle driver module provides for needle cannula rotation, needle insertion and cannula retraction to enable the brachytherapy procedure with the preloaded needles. The device mimics the manual physician gesture by two point grasping (hub and base) and provides direct force measurement of needle insertion force by fiber optic force sensors. The fabricated prototype is presented and an experiment with phantom trials in 3T MRI is analyzed to demonstrate the system compatibility. PMID:21335868

  19. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  20. Long-term follow-up after neoplastic seeding complicating percutaneous ethanol injection for treatment of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Arrive, L.; Vurgait, A.; Monnier-Cholley, L.; Lewin, M.; Tubiana, J.M.; Balladur, P.; Poupon, R.

    2002-01-01

    We describe a case of subcutaneous metastasis along the needle track after percutaneous ethanol injection (PEI) for treatment of hepatocellular carcinoma. After surgical resection and extrabeam radiation therapy the patient is alive without evidence of recurrence five years after PEI. One should pay attention to the abdominal wall around the needle track in interpreting CT or MR images of patients with previous PEI. (orig.)

  1. Percutaneous nephrolithotomy with and without retrograde pyelography: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Ali Tabibi

    2007-02-01

    Full Text Available OBJECTIVE: Since the introduction of percutaneous nephrolithotomy (PCNL, many changes have been added regarding the entrance to pyelocalyceal system such as insertion of the needle pointed to an opaque stone as a guided landmark. We aim at comparing the outcomes of managing renal calculi with and without retrograde pyelography. MATERIALS AND METHODS: In a randomized clinical trial, 55 cases with opaque renal calculi candidates for PCNL with stone in one calyce, in the pelvis or both in one calyce and the pelvis simultaneously were included in a nine-month study. They were randomized into 2 groups, noncatheterized (n = 28 and catheterized (n = 27, called intervention and control groups, respectively. RESULTS: The 2 groups had similar distributions regarding gender, age, duration of operation, length of hospital stay, past history of any surgical procedures on kidney, and stone size. Outcome (residual stone based on aforementioned management was evaluated with plain X-ray on the morning following the operation. Postoperative hemoglobin decrease was significantly higher in controls than in the intervention group (p < 0.001 (with no clinical significance. No difference in outcome, postoperative fever, duration of surgery, duration of hospital stay and radiation exposure was observed between the 2 groups. CONCLUSION: Our findings showed no differences in major clinical outcomes between the 2 groups (with and without catheter insertion for retrograde pyelography.

  2. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  3. PERCUTANEOUS ELECTROHEMOSTASIS AFTER PERCUTANEOUS NEPHROLITHOTOMY

    Directory of Open Access Journals (Sweden)

    R. N. Trushkin

    2017-01-01

    Full Text Available The article describes the clinical case in a patient with bilateral nephrolithiasis, chronic kidney disease of the 4th stage, after which bleeding from the left kidney developed after simultaneous bilateral percutaneous nephrolithotomy (PNL, leading to severe hemic hypoxia. Conservative therapy, blood transfusion did not lead to a persistent effect, the bleeding continued to recur. Given the presence of chronic renal failure (CRF from the embolization of the branches of the renal artery, it was decided to abstain, given the extremely high risk of aggravation of nephropathy after the administration of the contrast drug. Left-sided nephrectomy would inevitably lead to the development of terminal chronic renal failure. Patients performed an electrocoagulation of the fistula wall with a Karl Storz 26C resectoscope in 60W mode. The bleeding was completely stopped. The patient is discharged from the hospital in a satisfactory condition. At the time of discharge in the conduct of replacement renal therapy did not need. When analyzing publications in The Cochrane Library, PubMed, Medline and Web of Science, we did not find a description of such a method of hemostasis.

  4. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  5. Percutaneous drainage of 100 subphrenic abscesses

    International Nuclear Information System (INIS)

    Casola, G.; Sonnenberg, E. van; D'Agostino, H.; Kothari, R.; May, S.; Taggart, S.

    1990-01-01

    PURPOSE: Percutaneous drainage of subphrenic abscesses is technically more difficult because lung and pleura may be transgressed during catheter insertion. The purpose of this paper is to determine the incidence of thoracic complications secondary to subphrenic abscess drainage and to determine factors that may alter this. The authors' series consists of 100 subphrenic abscesses that were drained percutaneously. Patients range in age from 14 to 75 years. Abscesses were secondary to surgery (splenectomy, pancreatectomy, partial hepatectomy, gastrectomy), pancreatitis, and trauma. Catheters ranged in size from 8 to 14 F and were inserted via trocar or Seldinger technique. Thoracic complications of pneumothorax or empyema were determined from follow-up chest radiographs or CT scans

  6. Treatment of malignant biliary occlusion by means of transhepatic percutaneous biliary drainage with insertion of metal stents - results of an 8-year follow-up and analysis of the prognostic parameters; Behandlung der malignen Gallenwegsstenose mittels perkutaner transhepatischer Metallendoprothesenimplantation: 8 Jahres-Ergebnisse und Analyse prognostischer Faktoren

    Energy Technology Data Exchange (ETDEWEB)

    Alfke, H.; Alfke, B.; Froelich, J.J.; Klose, K.J.; Wagner, H.J. [Klinik fuer Strahlendiagnostik Philipps Univ. Marburg (Germany)

    2003-08-01

    Purpose: To analyze outcome and predictive factors for patient survival and patency rates of unresectable malignant biliary obstruction treated with percutaneous transhepatic insertion of metal stents. Materials and Methods: This is a retroselective analysis of 130 patients treated in one interventional radiological center with data collected from patient records and by telephone interviews. The procedure-related data had been prospectively documented in a computer data base. The Kaplan-Meier analysis was performed for univariate and multivariate comparison of survival and patency rates with the log-rank test used for different tumor types. Predictive factors for survival and 30-day mortality were analyzed by a stepwise logistic regression. Results: Underlying causes of malignant biliary obstructions were cholangiocarcinoma in 50, pancreatic carcinoma in 29, liver metastases in 27, gallbladder carcinoma in 20, and other tumors in 4 patients. The technical success rate was 99%, the complication rate 27% and the 30-day mortality 11%. Primary patency rates (406 days with a median of 207 days) did not differ significantly for different tumor types. The survival rates were significantly (p = 0.03 by log-rank test) better for patients with cholangiocarcinoma than for patients with pancreatic carcinoma and liver metastases. Multiple regression analysis revealed no predictive factor for patient survival and 30-day mortality. Conclusion: Percutaneous transhepatic insertion of metal biliary endoprostheses offers a good initial and long-term relief of jaundice caused by malignant biliary obstruction. Although survival rates for patients with cholangiocarcinoma are better than for other causes of malignant biliary obstruction, a clear predictive factor is lacking for patients undergoing palliative biliary stent insertion. (orig.) [German] Ziel: Ergebnisse der perkutanen transhepatischen Metallendoprothesenimplantation bei malignen Gallenwegsverschluessen zu evaluieren und

  7. Needle phobia during pregnancy.

    Science.gov (United States)

    Searing, Kimberly; Baukus, Mary; Stark, Mary Ann; Morin, Karen H; Rudell, Barb

    2006-01-01

    The objective of this study was to understand the experience of a pregnant woman with needle phobia and examine its impact on her antepartum, intrapartum, and postpartum experience. A case study format was employed. A 21-year-old primiparous woman with diagnosed needle phobia was interviewed, and her prenatal and delivery records were reviewed. Three tasks during pregnancy were identified: seeking trusting relationships with health care providers; establishing and maintaining control and understanding; and coping with fear of needles, pain, and invasion. As frequent caregivers during childbearing, nurses with an understanding of needle phobia can help to establish trusting relationships with women with this phobia and support them and their families during childbearing and their encounters with needles. (c) 2006, AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses

  8. Ureteroscopy-assisted Percutaneous Kidney Access Made Easy: First Clinical Experience with a Novel Navigation System Using Electromagnetic Guidance (IDEAL Stage 1).

    Science.gov (United States)

    Lima, Estevao; Rodrigues, Pedro L; Mota, Paulo; Carvalho, Nuno; Dias, Emanuel; Correia-Pinto, Jorge; Autorino, Riccardo; Vilaça, João L

    2017-10-01

    Puncture of the renal collecting system represents a challenging step in percutaneous nephrolithotomy (PCNL). Limitations related to the use of standard fluoroscopic-based and ultrasound-based maneuvers have been recognized. To describe the technique and early clinical outcomes of a novel navigation system for percutaneous kidney access. This was a proof-of-concept study (IDEAL phase 1) conducted at a single academic center. Ten PCNL procedures were performed for patients with kidney stones. Flexible ureterorenoscopy was performed to determine the optimal renal calyx for access. An electromagnetic sensor was inserted through the working channel. Then the selected calyx was punctured with a needle with a sensor on the tip guided by real-time three-dimensional images observed on the monitor. The primary endpoints were the accuracy and clinical applicability of the system in clinical use. Secondary endpoints were the time to successful puncture, the number of attempts for successful puncture, and complications. Ten patients were enrolled in the study. The median age was 47.1 yr (30-63), median body mass index was 22.85kg/m 2 (19-28.3), and median stone size was 2.13cm (1.5-2.5cm). All stones were in the renal pelvis. The Guy's stone score was 1 in nine cases and 2 in one case. All 10 punctures of the collecting system were successfully completed at the first attempt without X-ray exposure. The median time to successful puncture starting from insertion of the needle was 20 s (range 15-35). No complications occurred. We describe the first clinical application of a novel navigation system using real-time electromagnetic sensors for percutaneous kidney access. This new technology overcomes the intrinsic limitations of traditional methods of kidney access, allowing safe, precise, fast, and effective puncture of the renal collecting system. We describe a new technology allowing safe and easy puncture of the kidney without radiation exposure. This could significantly

  9. Percutaneous biopsy of the synovial membrane of large joints

    International Nuclear Information System (INIS)

    Begule, V.

    1989-01-01

    Using flouroscopy, the authors have developed new techniques of percutaneous synovial biopsy (PSB) of large joints of limbs (other than the knee). PSB was performed on outpatients under local anesthesia. They have performed 84 biopsies (hips: 57), shoulders: 10, elbows: six, wrists: five, ankles: six). The PSB technique was gradually improved. Main technical refinements were use of a Tru-Cut needle introduced through a Jamshidi trephine needle, placement of the cutting window parallel to the anterior aspect of the joint, and selection of an optimal approach and biopsy site. With these improvements, the success rate of attaining synovial membrane was raised from 49% to 81%. No complications were encountered

  10. Total Percutaneous Aortic Repair: Midterm Outcomes

    International Nuclear Information System (INIS)

    Bent, Clare L.; Fotiadis, Nikolas; Renfrew, Ian; Walsh, Michael; Brohi, Karim; Kyriakides, Constantinos; Matson, Matthew

    2009-01-01

    The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 ± 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 ± 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

  11. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    OpenAIRE

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian...

  12. NPIP: A skew line needle configuration optimization system for HDR brachytherapy

    International Nuclear Information System (INIS)

    Siauw, Timmy; Cunha, Adam; Berenson, Dmitry; Atamtürk, Alper; Hsu, I-Chow; Goldberg, Ken; Pouliot, Jean

    2012-01-01

    Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the final needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, δ. The candidate needle set consisted of 5000 needles, and a range of δ values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of δ values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many or fewer

  13. Modified microdissection electrocautery needle

    OpenAIRE

    Singh, Virendra; Kumar, Pramod

    2014-01-01

    Electrocautery is routinely used in surgical procedures. The commercially available microdissection electrocautery needles are costly. To overcome this disadvantage, we have modified monopolar electrocautery tip to function as well as commercially available systems.

  14. Percutaneous nephrolithotomy in very elderly patients (Age 75 and Over

    Directory of Open Access Journals (Sweden)

    Hüseyin Çelik

    2015-12-01

    Full Text Available Objective: Percutaneous nephrolithotomy (PNL is a minimally invasive method used safely in surgical treatment of kidney stones in the world. The first PNL surgery performed in our clinic in March 1998 and first PNL surgery was performed in June 2000 over the age of seventy which was bilaterally side. In our study, PNL operations performed for 75 years and older patients were examined. Methods: PNL operations were performed under the general anesthesia. After cystoscopy in the supine position, ureteral catheter was inserted accompanied by C-arm fluoroscopy. Afterwards, patients were taken prone position then we entered into the kidney with a metal needle with fluoroscopic on. We dilated the entrance with Amplatzer renal dilatators set until the 30 F. After the procedure, the nephrostomy catheter was placed in the renal sheath. 4 mm residual fragments after the PNL operation were accepted as clinically insignificant stone residues (CIRF. Results: 3003 PNL procedures were performed between dates March 1998 - December 2014 in total 16 years. 28 patients of total were 75 years and over. 29 PNL surgeries performed to these patients, including one bilateral PNL procedure. Mean age was 79.36 years (75-88. Twenty (74% of the patients were concluded stone free. 2 patients had tubeless PNL surgery. There was no another complication. Conclusion: PNL is a minimally invasive method has became advantageous according to open surgery because of higher safety, lower complication rates, shorter hospitalization stay, more patient comfort and higher stone free rates. PNL is a safe and effective method in the surgical treatment of urinary tract stone diseases.

  15. Percutaneous vertebroplasty with the rotational fluoroscopy imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Cannavale, Alessandro; Salvatori, Filippo Maria; Wlderk, Andrea; Cirelli, Carlo; D' Adamo, Alessandro; Fanelli, Fabrizio [University of Rome, Vascular and Interventional Unit, Department of Radiological Sciences, Rome (Italy)

    2014-11-15

    To evaluate the feasibility of the rotational angiography unit (RAU) as a single technique to guide percutaneous vertebroplasty (PVP). Twenty-five consecutive patients (35 vertebral bodies, 20 lumbar and 15 thoracic) were treated using RA fluoroscopy. Using a state-of-the-art flat-panel angiographer (Artis zee, Siemens, Erlangen, Germany), rotational acquisitions were obtained in all patients for immediate post-procedure 2D/3D reconstructions. Pre- and postoperative back pain was assessed with the visual analog scale (VAS). Fluoroscopy time, patient radiation dose exposure, technical success, mean procedure time, mean number of rotational acquisitions and procedural complications were recorded. All features were compared with a historical cohort of patients (N = 25) who underwent PVP under CT and mobile C-arm fluoroscopy guidance. In all cases, safe and accurate control of the needle insertion and bone-cement injection was successfully obtained with high-quality fluoroscopy images. One cement leakage was detected in the RAU group, and two leakages were detected in the CT and C-arm fluoroscopy group. Technical features were significantly different between the two groups (RAU vs. CT): mean procedure time: 38.2 min vs. 60.2 min (p = 0.02); median fluoroscopy time: 14.58 and 4.58 min (p = 0.02); median number of rotational acquisitions: 5 vs. 10 (p = 0.02); mean patient dose: 6 ± 1.3 mSv vs. 23 ± 1.3 mSv (p = 0.02). There were minor complications (pain, small hematoma) in two patients (8%) in the study group and three cases (12%) in the control group. RAU guidance is an effective and safe technique for performing PVP because it reduces the procedural time and radiation exposure. (orig.)

  16. Experience with three percutaneous vena cava filters

    International Nuclear Information System (INIS)

    McCowan, T.C.; Ferris, E.J.; Harshfield, D.L.; Hassell, D.R.; Baker, M.L.

    1987-01-01

    Twenty-one Kimray-Greenfield, 33 bird's nest, and 19 Amplatz vena cava filters were placed percutaneously. The Kimray-Greenfield filter was the most difficult to insert. The major problem was the insertion site, which required venipuncture with a 24-F catheter. Minor hemorrhage was frequent, and femoral vein thrombosis occurred in four patients. No migration, caval thrombosis, or pulmonary emboli were seen after Kimray-Greenfield filter placement. The bird's nest filter was relatively easy to insert, although in two cases the filter prongs could not be adequately seated in the wall of the inferior vena cava. Three patients with bird's nest filters had thrombosis below the filter, and three filters migrated to the heart. One migrated filter could not be removed. One patient had multiple small pulmonary emboli at autopsy. No other pulmonary emboli after filter placement were noted. The Amplatz filter was the easiest of the three filters to insert. Only one patient with an Amplatz filter had thrombosis of the vena cava below the filter. No filter migrations were documented, and no recurrent pulmonary emboli were found on clinical or radiologic follow-up. The Amplatz vena cava filter is easier to place than percutaneous Kimray-Greenfield or bird's nest filters, has a low complication rate, and has proven to be clinically effective in preventing pulmonary emboli

  17. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    Science.gov (United States)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  18. Steering of flexible needles combining kinesthetic and vibratory force feedback

    NARCIS (Netherlands)

    Pacchierotti, Claudio; Abayazid, Momen; Misra, Sarthak; Prattichizzo, Domenico

    2014-01-01

    Needle insertion in soft-tissue is a minimally invasive surgical procedure which demands high accuracy. In this respect, robotic systems with autonomous control algorithms have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and acceptance by

  19. High-pressure needle interface for thermoplastic microfluidics.

    Science.gov (United States)

    Chen, C F; Liu, J; Hromada, L P; Tsao, C W; Chang, C C; DeVoe, D L

    2009-01-07

    A robust and low dead volume world-to-chip interface for thermoplastic microfluidics has been developed. The high pressure fluidic port employs a stainless steel needle inserted into a mating hole aligned to an embedded microchannel, with an interference fit used to increase pressure resistance. Alternately, a self-tapping threaded needle screwed into a mating hole is also demonstrated. In both cases, the flat bottom needle ports seat directly against the microchannel substrate, ensuring low interfacial dead volumes. Low dispersion is observed for dye bands passing the interfaces. The needle ports offer sufficient pull-out forces for applications such as liquid chromatography that require high internal fluid pressures, with the epoxy-free interfaces compatible with internal microchannel pressures above 40 MPa.

  20. Percutaneous catheter drainage of lung abscess

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub [Catholic University Medical college, Seoul (Korea, Republic of)

    1993-09-15

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess.

  1. Percutaneous catheter drainage of lung abscess

    International Nuclear Information System (INIS)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub

    1993-01-01

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess

  2. Percutaneous transcholecystic approach for an experiment of biliary stent placement: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Medical School of Gachon, Inchon (Korea, Republic of); Song, Ho Young; Lim, Jin Oh; Ko, Gi Young; Sung, Kyu Bo; Kim, Tae Hyung; Lee, Ho Jung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-06-01

    To determine, in an experimental study of biliary stent placement, the usefulness and safety of the percutaneous transcholecystic approach and the patency of a newly designed biliary stent. A stent made of 0.15-mm-thick nitinol wire, and 10 mm in diameter and 2 cm in length, was loaded in an introducer with an 8-F outer diameter. The gallbladders of seven mongrel dogs were punctured with a 16-G angiocath needle under sonographic guidance, and cholangiography was performed. After anchoring the anterior wall of the gallbladder to the abdominal wall using a T-fastener, the gallbladder body was punctured again under fluoroscopic guidance. The cystic and common bile ducts were selected using a 0.035-inch guide wire and a cobra catheter, and the stent was placed in the common bile duct. Post-stenting cholangiography was undertaken, and an 8.5-F drainage tube was inserted in the gallbladder. Two dogs were followed-up and sacrificed at 2,4 and 8 weeks after stent placement, respectively, and the other expired 2 days after stent placement. Follow-up cholangiograms were obtained before aninmal was sacrified, and a pathologic examination was performed. Stent placement was technically successful in all cases. One dog expired 2 days after placement because of bile peritonitis due to migration of the drainage tube into the peritoneal cavity, but the other six remained healthy during the follow-up period. Cholangiography performed before the sacrifice of each dog showed that the stents were patent. Pathologic examination revealed the proliferation of granulation tissue at 2 weeks, and complete endothelialization over the stents by granulation tissue at 8 weeks. Percutaneous transcholecystic biliary stent placement appears to be safe, easy and useful. After placement, the stent was patent during the follow-period.

  3. Experimental examinations with a new percutaneously insertable, expandable vascular endoprosthesis

    International Nuclear Information System (INIS)

    Strecker, E.P.; Berg, G.; Weber, H.; Bohl, M.; Dietrich, B.; Freiburg Univ.; Karlsruhe Univ.

    1987-01-01

    Restenosis and occlusion are the most common reasons why transluminal balloon angioplasty may fail to provide long-term benefit. To prevent restonosis and occlusion of diseased arteries after angioplasty an arterial endoprosthesis has been developed which is positioned to the balloon of an angioplasty catheter and which consists of a stainless steel pliable and elastic tube. With the inflation of the balloon the endoprosthesis will dilate and give the arterial wall a new mechanical support. This new device has been implanted in 12 experimental dogs in arteries of different size and lumen. The longest patency rate of nine months was observed with the completely developed method. (orig.) [de

  4. Percutaneous biliary drainage and stenting

    International Nuclear Information System (INIS)

    Totev, M.

    2012-01-01

    Full text: Percutaneous transhepatic cholangiography (PTC) is an X-ray or US guided procedure that involves the injection of a contrast material directly into the bile ducts inside the liver to produce pictures of them. If a blockage or narrowing is found, additional procedures may be performed: 1. insertion of a catheter to drain excess bile out of the body or both - internal and external; 2. plastic endoprothesis placement; 3. self-expandable metal stents placement to help open bile ducts or to bypass an obstruction and allow fluids to drain. Current percutaneous biliary interventions include percutaneous transhepatic cholangiography (PTC) and biliary drainage to manage benign and malignant obstructions. Internal biliary stents are either plastic or metallic, and various types of each kind are available. Internal biliary stents have several advantages. An external tube can be uncomfortable and have a psychological disadvantage. An internal stent prevents the problems related to external catheters, for example, pericatheter leakage of bile and the need for daily flushing. The disadvantages include having to perform endoscopic retrograde cholangiopancreatography (ERCP) or new PTC procedures to obtain access in case of stent obstruction. Better patency rates are reported with metallic than with plastic stents in cases of malignant obstruction, though no effect on survival is noted. Plastic internal stents are the cheapest but reportedly prone to migration. Metallic stents are generally not used in the treatment of benign disease because studies have shown poor long-term patency rates. Limited applications may include the treatment of patients who are poor surgical candidates or of those in whom surgical treatment fails. Most postoperative strictures are treated surgically, though endoscopic and (less commonly) percutaneous placement of nonmetallic stents has increasingly been used in the past few years. Now there are some reports about use of biodegradable biliary

  5. Lattice insertions for POPAE

    International Nuclear Information System (INIS)

    Cho, Y.; Crosbie, E.A.; Diebold, R.; Johnson, D.E.; Ohnuma, S.; Ruggiero, A.G.; Teng, L.C.

    1977-01-01

    Four types of insertions are described for the six 200-m straight sections of POPAE. All have dispersion matched to zero. (1) Injection-ejection insertion--This has proper high-β values and phase advances for horizontal injection and vertical ejection. (2) Phase-adjust insertion--The phase advance in this insertion is adjustable over a range of approximately 100 0 . (3) General-purpose insertion--The β* is adjustable from 2.5. to 200 m and the crossing angle is adjustable from 0 to 11 mrad. (4) High-luminosity insertion--This gives an even lower β + of meter

  6. Percutaneous transhepatic biliary drainage

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Hong, Seong Mo; Han, Man Chung

    1982-01-01

    Percutaneous transhepatic biliary drainage was successfully made 20 times on 17 patients of obstructive jaundice for recent 1 year since June 1981 at Department of Radiology in Seoul National University Hospital. The causes of obstructive jaundice was CBD Ca in 13 cases, metastasis in 2 cases, pancreatic cancer in 1 case and CBD stone in 1 case. Percutaneous transhepatic biliary drainage is a relatively ease, safe and effective method which can be done after PTC by radiologist. It is expected that percutaneous transhepatic biliary drainage should be done as an essential procedure for transient permanent palliation of obstructive jaundice

  7. Clarification of the characteristics of needle-tip movement during vacuum venipuncture to improve safety.

    Science.gov (United States)

    Fujii, Chieko

    2013-01-01

    Complications resulting from venipuncture include vein and nerve damage, hematoma, and neuropathic pain. Although the basic procedures are understood, few analyses of actual data exist. It is important to improve the safety standards of this technique during venipuncture. This study aimed to obtain data on actual needle movement during vacuum venipuncture in order to develop appropriate educational procedures. Six experienced nurses were recruited to collect blood samples from 64 subjects. These procedures were recorded using a digital camera. Software was then used to track and analyze motion without the use of a marker in order to maintain the sterility of the needle. Movement along the X- and Y-axes during blood sampling was examined. Approximately 2.5 cm of the needle was inserted into the body, of which 6 mm resulted from advancing or moving the needle following puncture. The mean calculated puncture angle was 15.2°. Given the hazards posed by attaching and removing the blood collection tube, as well as by manipulating the needle to fix its position, the needle became unstable whether it was fixed or not fixed. This study examined venipuncture procedures and showed that the method was influenced by increased needle movement. Focusing on skills for puncturing the skin, inserting the needle into the vein, and changing hands while being conscious of needle-tip stability may be essential for improving the safety of venipuncture.

  8. [Exploration of acupoint combination and needling techniques in the reinforcing and reducing manipulation at different acupoints].

    Science.gov (United States)

    Dai, Qing; Sheng, Xiesun; Chen, Feng

    2017-04-12

    The reinforcing and reducing manipulation at different acupoints is a kind of acupuncture manipulations and has satisfactory clinical therapeutic effects, combined with a proper needling techniques. The reinforcing needling method is used in the upper and the reducing one in the lower, the distal acupoints are combined with the nearby acupoints. The local acupoints or adjcant acupoints of the affected area are regarded as the nearby acupoints, e.g. the acupoints in the upper. The distant acupoints and the acupoints on the hand and foot are named as distal acupoints, e.g. the acupoint in the lower. In the reinforcing manipulation, the needle is inserted shallowly along the running direction of meridian. In the reducing manipulation, the needle is inserted deeply and against the running direction of meridian. The yin - yang couple needling technique is used with the combination of the front- mu and back- shu points. In the first option, the reinforcing and reducing needling method with rotating technique is predominated at the front- mu points, while that with lifting and thrusting technique is at the back- shu points. In the second option, when needling the back- shu points, the needling sensation is transmitted along the transverse segment and far to the chest and abdomen. These two kinds of integration of acupoint combination and needling techniques display a certain clinical significance in improving the therapeutic effects of acupuncture.

  9. A Systematic Review of Outcomes Following Percutaneous Transluminal Angioplasty and Stenting in the Treatment of Transplant Renal Artery Stenosis

    NARCIS (Netherlands)

    Ngo, A. T.; Markar, S. R.; de Lijster, M. S.; Duncan, N.; Taube, D.; Hamady, M. S.

    2015-01-01

    To evaluate outcomes following treatment of transplant renal artery stenosis by percutaneous transluminal angioplasty and stent insertion. A literature search was performed using Pubmed, MEDLINE, Embase, Wiley Interscience and the Cochrane Library databases. Outcome measures were glomerular

  10. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  11. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    International Nuclear Information System (INIS)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook

    1995-01-01

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy

  12. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy.

  13. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  14. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  15. Feeding tube insertion - gastrostomy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002937.htm Feeding tube insertion - gastrostomy To use the sharing features on this page, please enable JavaScript. A gastrostomy feeding tube insertion is the placement of a feeding ...

  16. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  17. Efficacy of percutaneous microwave coagulation therapy for nodular hepatic tumor : a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seon Hee; Bang, Sun Woo; Baek, Seung Il; Kim, Ho Kyun [Inje Univ. College of Medicine, Seoul (Korea, Republic of); Kim, Jeong Seok [Dongguk Univ. College of Medicine, Seoul (Korea, Republic of)

    2001-04-01

    Percutaneous microwave coagulation therapy (PMCT) uses a new energy source, microwave, in the treatment of solid neoplasms. We evaluated the efficacy of PMCT for nodular hepatic tumors in nine patients. Between December 1998 and June 1999, we performed PMCT in six patients with hepatocelluar carcinoma (HCC), two with one and three metastatic nodules each from colon cancer, and one with adenomatous hyperplasia. Four patients were female and five were male, and their age ranged between 44 and 71 (mean, 58.8) years. Under sonographic guidance a 14-gauge guiding needle was inserted percutaneously toward the lesion, and within it a needle electrode was precisely positioned. Microwave 2450MHz in frequency and with 60 or 80-watt emission was generated for 80{approx}90 seconds. We evaluated the ultrasound findings obtained during the procedure, pre-PMCT and follow-up CT images, changes in tumor marker(AFP or CA19-9) levels and the results of liver function tests, and complications arising during the six-month period following PMCT. Immediately after microwave emission, characteristic hyperechogenicity appeared on the real-time sonogram. Two patients with HCC underwent CT before PMCT, and typical enhancement during the arterial phase and washout during the portovenous phase was observed. In one patient, two metastatic lesions from colon cancer showed delayed enhancement on pre-PMCT CT. Initial follow-up CT, performed between I and 4 weeks after the PMCT procedure, showed that eight lesions-including two HCCs which were highly enhanced on CT before PMCT-showed no contrast enhancement, and three others showed delayed enhancement. Two of the eight lesions which showed no contrast enhancement at initial follow-up CT were markedly decreased in size (from 2.9 and 4.0 cm to 1.0 and 2.0 cm, respectively) at subsequent follow-up 3 months and 6 months later, respectively. One of the three lesions showing delayed enhancement had increased in size from 4.1 to 5.5 cm at subsequent

  18. Treatment of hilar cholangiocarcinoma with inserting biliary double stents

    International Nuclear Information System (INIS)

    Jia Guangzhi; Zhang Zidong; Wang Xuejing; Yin Hua; Li Jianming

    2004-01-01

    Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 ± 29) μmol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

  19. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  20. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  1. Accuracy evaluation of a 3D-printed individual template for needle guidance in head and neck brachytherapy

    International Nuclear Information System (INIS)

    Huang, Ming-Wei; Zhang, Jian-Guo; Zheng, Lei; Liu, Shu-Ming; Yu, Guang-Yan

    2016-01-01

    To transfer the preplan for the head and neck brachytherapy to the clinical implantation procedure, a preplan-based 3D-printed individual template for needle insertion guidance had previously been designed and used. The accuracy of needle insertion using this kind template was assessed in vivo. In the study, 25 patients with head and neck tumors were implanted with 125 I radioactive seeds under the guidance of the 3D-printed individual template. Patients were divided into four groups based on the site of needle insertion: the parotid and masseter region group (nine patients); the maxillary and paranasal region group (eight patients); the submandibular and upper neck area group (five patients); and the retromandibular region group (six patients). The distance and angular deviations between the preplanned and placed needles were compared, and the complications and time required for needle insertion were assessed. The mean entrance point distance deviation for all 619 needles was 1.18 ± 0.81 mm, varying from 0.857 ± 0.545 to 1.930 ± 0.843 mm at different sites. The mean angular deviation was 2.08 ± 1.07 degrees, varying from 1.85 ± 0.93 to 2.73 ± 1.18 degrees at different sites. All needles were manually inserted to their preplanned positions in a single attempt, and the mean time to insert one needle was 7.5 s. No anatomical complications related to inaccurately placed implants were observed. Using the 3D-printed individual template for the implantation of 125 I radioactive seeds in the head and neck region can accurately transfer a CT-based preplan to the brachytherapy needle insertion procedure. Moreover, the addition of individual template guidance can reduce the time required for implantation and minimize the damage to normal tissues.

  2. The relationship between fear and pain levels during needle procedures in children from the parents' perspective.

    Science.gov (United States)

    Hedén, L; von Essen, L; Ljungman, G

    2016-02-01

    The primary objective was to determine the levels of and potential relationships between procedure-related fear and pain in children. Secondary objectives were to determine if there are associations between the child's age and sex, diagnostic group, time since diagnosis, time since last needle insertion, cortisol levels and the parent's fear level in relation to fear and pain. The child's level of pain and fear was reported by parents on 0-100 mm visual analogue scales (VAS). One hundred and fifty-one children were included consecutively when undergoing routine needle insertion into a subcutaneously implanted intravenous port. All children were subjected to one needle insertion following topical anaesthesia (EMLA) application. The effect of the child's age and sex, diagnostic group, time since diagnosis, time since last needle insertion, cortisol change levels and the parent's fear level, on fear and pain levels was investigated with multiple regression analysis. The needle-related fear level (VAS mean 28 mm) was higher than the needle-related pain level (VAS mean 17 mm) when topical anaesthesia is used according to parents' reports (n = 151, p fear as the dependent variable, age and pain were significantly associated and explained 33% of the variance, and with pain as the dependent variable, fear, parents' fear and change in cortisol level were significantly associated and explained 38% of the variance. According to parents, children experienced more fear than pain during needle insertion when topical anaesthesia is used. Therefore, in addition to pain management, an extended focus on fear-reducing interventions is suggested for needle procedures. © 2015 European Pain Federation - EFIC®

  3. Needle Decompression in Appalachia Do Obese Patients Need Longer Needles?

    Directory of Open Access Journals (Sweden)

    Carter, Thomas Edward

    2013-11-01

    Full Text Available Introduction: Needle decompression of a tension pneumothorax can be a lifesaving procedure. It requires an adequate needle length to reach the chest wall to rapidly remove air. With adult obesity exceeding one third of the United States population in 2010, we sought to evaluate the proper catheter length that may result in a successful needle decompression procedure. Advance Trauma Life Support (ATLS currently recommends a 51 millimeter (mm needle, while the needles stocked in our emergency department are 46 mm. Given the obesity rates of our patient population, we hypothesize these needles would not have a tolerable success rate of 90%. Methods: We retrospectively reviewed 91 patient records that had computed tomography of the chest and measured the chest wall depth at the second intercostal space bilaterally. Results: We found that 46 mm needles would only be successful in 52.7% of our patient population, yet the ATLS recommended length of 51 mm has a success rate of 64.8%. Therefore, using a 64 mm needle would be successful in 79% percent of our patient population. Conclusion: Use of longer length needles for needle thoracostomy is essential given the extent of the nation’s adult obesity population. [West J Emerg Med. 2013;14(6:650-652.

  4. Needle-like instruments for steering through solid organs : A review of the scientific and patent literature

    NARCIS (Netherlands)

    Scali, M.; Pusch, T.P.; Breedveld, P.; Dodou, D.

    2017-01-01

    High accuracy and precision in reaching target locations inside the human body is necessary for the success of percutaneous procedures, such as tissue sample removal (biopsy), brachytherapy, and localized drug delivery. Flexible steerable needles may allow the surgeon to reach targets deep inside

  5. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won

    1996-01-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications

  6. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1996-10-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications.

  7. Needle-tissue interactive mechanism and steering control in image-guided robot-assisted minimally invasive surgery: a review.

    Science.gov (United States)

    Li, Pan; Yang, Zhiyong; Jiang, Shan

    2018-06-01

    Image-guided robot-assisted minimally invasive surgery is an important medicine procedure used for biopsy or local target therapy. In order to reach the target region not accessible using traditional techniques, long and thin flexible needles are inserted into the soft tissue which has large deformation and nonlinear characteristics. However, the detection results and therapeutic effect are directly influenced by the targeting accuracy of needle steering. For this reason, the needle-tissue interactive mechanism, path planning, and steering control are investigated in this review by searching literatures in the last 10 years, which results in a comprehensive overview of the existing techniques with the main accomplishments, limitations, and recommendations. Through comprehensive analyses, surgical simulation for insertion into multi-layer inhomogeneous tissue is verified as a primary and propositional aspect to be explored, which accurately predicts the nonlinear needle deflection and tissue deformation. Investigation of the path planning of flexible needles is recommended to an anatomical or a deformable environment which has characteristics of the tissue deformation. Nonholonomic modeling combined with duty-cycled spinning for needle steering, which tracks the tip position in real time and compensates for the deviation error, is recommended as a future research focus in the steering control in anatomical and deformable environments. Graphical abstract a Insertion force when the needle is inserted into soft tissue. b Needle deflection model when the needle is inserted into soft tissue [68]. c Path planning in anatomical environments [92]. d Duty-cycled spinning incorporated in nonholonomic needle steering [64].

  8. Preclinical evaluation of an MRI-compatible pneumatic robot for angulated needle placement in transperineal prostate interventions

    Science.gov (United States)

    Tokuda, Junichi; Song, Sang-Eun; Fischer, Gregory S.; Iordachita, Iulian; Seifabadi, Reza; Cho, Bong Joon; Tuncali, Kemal; Fichtinger, Gabor; Tempany, Clare M.; Hata, Nobuhiko

    2013-01-01

    Purpose To evaluate the targeting accuracy of a small profile MRI-compatible pneumatic robot for needle placement that can angulate a needle insertion path into a large accessible target volume. Methods We extended our MRI-compatible pneumatic robot for needle placement to utilize its four degrees-of-freedom (4-DOF) mechanism with two parallel triangular structures and support transperineal prostate biopsies in a closed-bore magnetic resonance imaging (MRI) scanner. The robot is designed to guide a needle towards a lesion so that a radiologist can manually insert it in the bore. The robot is integrated with navigation software that allows an operator to plan angulated needle insertion by selecting a target and an entry point. The targeting error was evaluated while the angle between the needle insertion path and the static magnetic field was between −5.7° and 5.7° horizontally and between −5.7° and 4.3° vertically in the MRI scanner after sterilizing and draping the device. Results The robot positioned the needle for angulated insertion as specified on the navigation software with overall targeting error of 0.8 ± 0.5 mm along the horizontal axis and 0.8 ± 0.8 mm along the vertical axis. The two-dimensional root-mean-square targeting error on the axial slices as containing the targets was 1.4 mm. Conclusions Our preclinical evaluation demonstrated that the MRI-compatible pneumatic robot for needle placement with the capability to angulate the needle insertion path provides targeting accuracy feasible for clinical MRI-guided prostate interventions. The clinical feasibility has to be established in a clinical study. PMID:22678723

  9. Percutaneous treatment of intervertebral disc herniation.

    Science.gov (United States)

    Buy, Xavier; Gangi, Afshin

    2010-06-01

    Interventional radiology plays a major role in the management of symptomatic intervertebral disc herniations. In the absence of significant pain relief with conservative treatment including oral pain killers and anti-inflammatory drugs, selective image-guided periradicular infiltrations are generally indicated. The precise control of needle positioning allows optimal distribution of steroids along the painful nerve root. After 6 weeks of failure of conservative treatment including periradicular infiltration, treatment aiming to decompress or remove the herniation is considered. Conventional open surgery offers suboptimal results and is associated with significant morbidity. To achieve minimally invasive discal decompression, different percutaneous techniques have been developed. Their principle is to remove a small volume of nucleus, which results in an important reduction of intradiscal pressure and subsequently reduction of pressure inside the disc herniation. However, only contained disc herniations determined by computed tomography or magnetic resonance are indicated for these techniques. Thermal techniques such as radiofrequency or laser nucleotomy seem to be more effective than purely mechanical nucleotomy; indeed, they achieve discal decompression but also thermal destruction of intradiscal nociceptors, which may play a major role in the physiopathology of discal pain. The techniques of image-guided spinal periradicular infiltration and percutaneous nucleotomy with laser and radiofrequency are presented with emphasis on their best indications.

  10. When size matters: diagnostic value of kidney biopsy according to the gauge of the biopsy needle.

    Science.gov (United States)

    Roth, Rachel; Parikh, Samir; Makey, Dayanand; Foster, Jamison; Rozenblit, Grigory; Satoskar, Anjali; Nadasdy, Gyongyi; Von Visger, Jon; Hebert, Lee; Rovin, Brad H; Nadasdy, Tibor; Brodsky, Sergey V

    2013-01-01

    Kidney biopsy is a vital tool in the diagnosis of kidney disease. Although it has become a routine procedure, it is not complication-free. Some serious complications of percutaneous kidney biopsy include retroperitoneal hemorrhage and death. There is an increased belief that smaller biopsy needle size results in a lower complication rate. As renal pathologists, we witness an increased number of kidney biopsies performed with a small needle size (as low as gauge 22), which results in inadequate tissue sampling and often non-diagnostic biopsy results. Herein we report the diagnostic value of kidney biopsies according to the size of the biopsy needles. We performed kidney biopsies from nephrectomy specimens using biopsy needles of different sizes. Morphologic parameters were analyzed. We found that biopsies performed by small needles (gauges 20 and 22) contain significantly lower numbers of glomeruli and blood vessels, which limits pathologic evaluation. Data from our institution do not show differences in kidney biopsy complication rates between 16- and 18-gauge needles. Our data indicate that small biopsy needles do not provide sufficient material for diagnosis, and they increase the likelihood for a repeat biopsy. Copyright © 2013 S. Karger AG, Basel.

  11. Percutaneous injuries among dental professionals in Washington State

    Directory of Open Access Journals (Sweden)

    Shah Syed M

    2006-10-01

    Full Text Available Abstract Background Percutaneous exposure incidents facilitate transmission of bloodborne pathogens such as human immunodeficiency virus (HIV, hepatitis C virus (HCV and hepatitis B virus (HBV. This study was conducted to identify the circumstances and equipment related to percutaneous injuries among dental professionals. Methods We used workers' compensation claims submitted to the Department of Labor and Industries State Fund during a 7-year period (1995 through 2001 in Washington State for this study. We used the statement submitted by the injured worker on the workers' compensation claim form to determine the circumstances surrounding the injury including the type of activity and device involved. Results Of a total of 4,695 accepted State Fund percutaneous injury claims by health care workers (HCWs, 924 (20% were submitted by dental professionals. Out of 924 percutaneous injuries reported by dental professionals 894 (97% were among dental health care workers in non-hospital settings, including dentists (66, 7%, dental hygienists (61, 18% and dental assistants (667, 75%. The majority of those reporting were females (638, 71%. Most (781, 87% of the injuries involved syringes, dental instruments (77, 9%, and suture needles (23%. A large proportion (90% of injuries occurred in offices and clinics of dentists, while remainder occurred in offices of clinics and of doctors of medicine (9%, and a few in specialty outpatient facilities (1%. Of the 894 dental health care workers with percutaneous injuries, there was evidence of HBV in 6 persons, HCV in 30 persons, HIV in 3 persons and both HBV and HVC (n = 2 exposure. Conclusion Out of hospital percutaneous injuries are a substantial risk to dental health professionals in Washington State. Improved work practices and safer devices are needed to address this risk.

  12. Percutaneous gastrostomy and jejunostomy: Technique, results, and complications in 55 cases

    International Nuclear Information System (INIS)

    Mueller, P.R.; Brown, A.; Saini, S.; Hahn, P.F.; Steiner, E.; Ferrucci, J.T.; Forman, B.H.; Silverman, S.G.

    1987-01-01

    Percutaneous radiologic gastrostomy is a well-described method that has not been widely adopted by radiologists. The authors reviewed their experience to highlight technical points and clinical results. Direct percutaneous gastrostomy was performed in 51 patients and percutaneous jejunostomy in four. Indications for gastrostomy procedures were the need for general nutrition (n = 31), complications of use of a nasogastric feeding tube (n = 7), gastric or small bowel decompression (n = 4) and endoscopic failure (n = 5). The major indication for percutaneous jejunostomy was decompression of small bowel obstruction. Key technical aspects include the use of a novel needle device that tacks the abdominal wall to the stomach, thus assuring a seal between the two structures. In the percutaneous gastrostomies, 18-F Foley catheters were introduced through the tacked portion of the stomach with a Seldinger technique and dilators. For percutaneous jejunostomy, 18-F feeding tubes were placed. All procedures were performed under local anesthesia. The authors conclude that a radiologic percutaneous gastrostomy is a safe and effective procedure and should be pursued aggressively by interventional radiologists

  13. Percutaneous endoscopic gastrostomy in children

    Directory of Open Access Journals (Sweden)

    Jye Hae Park

    2011-01-01

    Full Text Available Purpose: Percutaneous endoscopic gastrostomy (PEG can improve nutritional status and reduce the amount of time needed to feed neurologically impaired children. We evaluated the characteristics, complications, and outcomes of neurologically impaired children treated with PEG. Methods: We retrospectively reviewed the records of 32 neurologically impaired children who underwent PEG between March 2002 and August 2008 at our medical center. Forty-two PEG procedures comprising 32 PEG insertions and 10 PEG exchanges, were performed. The mean follow-up time was 12.2 (6.6 months. Results: Mean patient age was 9.4 (4.5 years. The main indications for PEG insertion were swallowing difficulty with GI bleeding due to nasogastric tube placement and/or the presence of gastroesophageal reflux disease (GERD. The overall rate of complications was 47%, with early complications evident in 25% of patients and late complications in 22%. The late complications included one gastro-colic fistula, two cases of aggravated GERD, and four instances of wound infection. Among the 15 patients with histological evidence of GERD before PEG, 13 (87% had less severe GERD, experienced no new aspiration events, and showed increased body weight after PEG treatment. Conclusion: PEG is a safe, effective, and relatively simple technique affording long-term enteral nutritional support in neurologically impaired children. Following PEG treatment, the body weight of most patients increased and the levels of vomiting, GI bleeding, and aspiration fell. We suggest that PEG with post-procedural observation be considered for enteral nutritional support of neurologically impaired children.

  14. Ambulatory percutaneous nephrolithotomy: initial series.

    Science.gov (United States)

    Shahrour, Walid; Andonian, Sero

    2010-12-01

    To assess the safety and feasibility of ambulatory percutaneous nephrolithotomy (PCNL). PCNL is the gold standard for the management of large renal stones. Although tubeless PCNL has been previously described, no case series have been published of ambulatory PCNL. The criteria for ambulatory PCNL were: single tract, stone-free status documented by flexible nephroscopy, adequate pain control, and satisfactory postoperative hematocrit level and chest radiographic findings. Patient information, including operating room and fluoroscopy times, stone size and Hounsfield units, and number of needle punctures, were collected prospectively. The time spent in the recovery room, in addition to the amount of narcotics used in the recovery room and at home, was documented. Of 10 patients, 8 had nephrostomy tracts established intraoperatively by the urologist and 2 had preoperative nephrostomy tubes placed. The median operating and fluoroscopy time was 83.5 and 4.45 minutes, respectively. The median stone diameter was 20 mm (800 Hounsfield units) in addition to a patient with a staghorn calculus. The patients spent a median of 240 minutes in the recovery room and had received a median of 19.25 mg of morphine equivalents. Only 3 patients (30%) used narcotics at home. No intraoperative complications occurred, and none of the patients required transfusions. Two postoperative complications developed: a deep vein thrombosis requiring outpatient anticoagulation and multiresistant Escherichia coli infection requiring intravenous antibiotics. In highly selected patients, ambulatory PCNL is safe and feasible. More patients are needed to verify the criteria for patients undergoing the ambulatory approach. Copyright © 2010 Elsevier Inc. All rights reserved.

  15. Needle bar for warp knitting machines

    Science.gov (United States)

    Hagel, Adolf; Thumling, Manfred

    1979-01-01

    Needle bar for warp knitting machines with a number of needles individually set into slits of the bar and having shafts cranked to such an extent that the head section of each needle is in alignment with the shaft section accommodated by the slit. Slackening of the needles will thus not influence the needle spacing.

  16. A new device of CT-targeted percutaneous punctures

    International Nuclear Information System (INIS)

    Ozdoba, C.

    1990-01-01

    This paper reports on a device for CT-targeted percutaneous punctures. After extensive phantom studies, punctures of vertebral disk space (diskography/nucleotomy) and orbit retrobulbar anesthesia/biopsy were performed in 15 patients. The new device is easy to mount on the CT scanner and does not require additional devices affixed to the patient. Its design and construction permit exact calculation of needle angle and depth, even when the gantry is tilted. Percutaneous biopsies can be performed in approximately 40 minutes. The device is accurate within ±0.5 mm, thereby allowing puncture of even small lesions deep in the orbital cone. Retrobulbar anesthesia can be performed safely in patients with a long myopic bulbus; in nucleotomy, instant control of the instrument's position within the disk space is possible

  17. US-guided percutaneous ethanol injection in Plummer's adenoma

    International Nuclear Information System (INIS)

    Lagalla, R.; Iovane, A.; Caruso, G.; Midiri, N.; Oliveri, D.; Brancato, G.; Cardinale, A.

    1991-01-01

    The authors report their experience in the study of 8 patients showing sympoms of thyroid hyperfunction (Plummer's adenoma) and treated with US-guided percutaneous ethanol injection. The treatment consisted in injecting sterile ethanol in varying amounts (2 to 5 ml) according to nodule size, using a fine needle under US guidance. The patients underwent 3 to 6 injections, according to biochemical (T3-T4-TSH) and scintigraphic findings. Follow-up ay 12 months showed regression of clinical symptoms, a trend of hormone levels toward normalization and recovery of previously suppressed parenchymal function. No significant complications were observed, except for a transient thyrotoxic crisis in the patient bearing the largest nodule. The treatment of Plummer's adenoma by means of percutaneous ethanol injection under us guidance appears to provide specific clinical and technical advantages over other conventional treatments

  18. Needling the early universe

    International Nuclear Information System (INIS)

    Hawkins, I.; Wright, E.L.

    1988-01-01

    The possibility that the whole microwave background can be produced by a bright population of pregalactic stars at a redshift of a few hundred is explored. The radiation is thermalized by a combination of amorphous silicate, amorphous carbon, graphite, and needle-shaped conducting grains which give rise to the opacity needed at wavelengths greater than 3 cm. The occurrence of distortion in a primordial microwave background spectrum due to its interaction with Population III stars and dust is investigated. The possibility of producing deviations small enough to be consistent with the best available observations, but still detectable by COBE, is considered. 65 references

  19. Force-Sensor-Based Estimation of Needle Tip Deflection in Brachytherapy

    Directory of Open Access Journals (Sweden)

    Thomas Lehmann

    2013-01-01

    in real time during needle insertion is the main contribution of this paper. The proposed approach solely relies on the measured forces and torques without a need for any other invasive/noninvasive sensing devices. A few mechanical models have been introduced previously regarding the way the forces are composed along the needle during insertion; we will compare our model to those approaches in terms of accuracy. In order to conduct experiments to verify the deflection model, a custom-built, 2-DOF robotic system for needle insertion is developed and discussed. This system is a prototype of an intelligent, hand-held surgical assistant tool that incorporates the virtual sensor proposed in this paper.

  20. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    Science.gov (United States)

    Borot de Battisti, M.; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-10-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm3to 23.3 cm3) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.

  1. Serial changes on MR imaging of herniated lumber discs treated by percutaneous laser nucleotomy. Correlation with early clinical results

    International Nuclear Information System (INIS)

    Hiraishi, Kumiko; Ohmori, Naoki; Kosaka, Riya; Yonezawa, Takumi; Onomura, Toshinobu; Adachi, Itaru; Matsuoka, Takae; Honghan, Gong; Narabayashi, Isamu

    1996-01-01

    Percutaneous Laser Nucleotomy (PLN) is a new treatment for disc herniation applying neodymium: yttrium-aluminum-garnet (Nd : YAG) laser through inserted needle into the center of the disc, with less invasion and shorter hospitalization than conventional open surgery. Serial MR images were observed in 21 patients before and after PLN. Canal occupying ratio (COR) and signal intensity (S.I.) of herniated disc were measured. Recovery rate of symptoms was 57.2%, based on scoring system proposed by the Japanese Orthopaedic Association for low-back pain (JOA score). The successful group (≥30% improvement in JOA score) showed rapid decrease in signal intensity, though the ineffective group ( 2 -weighted sequence. Increase of signal intensity was observed in some patients whose symptoms had become worse. This may correlate with increase of water content and inner pressure on the disc. There was no significant difference between pre- and post-COR; however, more than 10% COR decrease was observed in 7 patients and symptoms improved in these cases. Thus the prognosis of the patients treated with PLN can be assessed by MR findings. (author)

  2. About the diagnostic accuracy rate of fluoroscopy-guided fine needle puncture

    International Nuclear Information System (INIS)

    Wernecke, K.; Teske, H.J.

    1983-01-01

    Percutaneous fine-needle biopsies guided by X-ray were performed in 100 patients utilizing the Nordenstroem canule. All cases have now been clinically controlled for at least 14 and up to 30 months. The follow up allowed further conclusions due to the dignity of histologically negative biopsies. Positive results on malignant lesions were obtained in 74% of cases. Our experience revealed that negative aspiration biopsies should be considered false negative until they could be confirmed by further investigations. (orig.) [de

  3. An asymptomatic needle in the left ventricular anterolateral wall: a prison inmate's strange radio antenna.

    Science.gov (United States)

    Akpinar, Ibrahim; Sayin, Muhammet Rasit; Karabag, Turgut; Dogan, Sait Mesut; Aydin, Mustafa

    2012-09-01

    A foreign body such as a needle in the heart can be life-threatening. While this may occur accidentally, needles may be inserted into the body by psychiatric patients or in cases involving domestic violence. A needle can migrate through the thorax toward the heart. In drug users, needles may also reach the right ventricle via the peripheral veins. Cardiac injury can occur via the esophagus after swallowing a needle. The clinical outcome may vary from an asymptomatic situation to tamponade or shock, depending on how severely the cardiac structures are affected. In injuries involving the thorax, pneumothorax may cause sudden shortness of breath. Here, we report the case of a 34-year-old male prison inmate who accidentally lodged a pin in his left ventricle while asleep. As he has refused surgery, it was decided to follow the patient carefully. © 2012, Wiley Periodicals, Inc.

  4. Percutaneous Transhepatic Cholangiography

    African Journals Online (AJOL)

    1974-03-30

    Mar 30, 1974 ... Percutaneous transhepatic cholangiography can play a major role in expediting the early diagnosis of surgically correctable jaundice. The need for this is emphasised by the fact that in a group of 46 patients the delay between the onset of jaundice and diagnosis ranged from 20 to 90 days. Transhepatic ...

  5. Nephron-sparing surgery and percutaneous biopsies in renal-cell carcinoma: a global impression among endourologists

    NARCIS (Netherlands)

    Kummerlin, Intan P. E. D.; Borrego, Jaime; Wink, Margot H.; van Dijk, Marleen M.; Wijkstra, Hessel; de La Rosette, Jean J. M. C. H.; Laguna, M. Pilar

    2007-01-01

    BACKGROUND AND PURPOSE: On the one hand, nephron-sparing surgery (NSS) in small renal tumors is a safe and effective alternative to radical nephrectomy. On the other hand, the role of preoperative percutaneous needle biopsies (PNB) remains controversial. The purpose of this study was to evaluate the

  6. Nephron-sparing surgery and percutaneous biopsies in renal-cell carcinoma : a global impression among endourologists

    NARCIS (Netherlands)

    Kummerlin, I.; Borrego, J.; Wink, M.H.; Dijk, van M.M.; Wijkstra, H.; Rosette, de la J.J.M.C.H.; Laguna, M.P.

    2010-01-01

    Background and Purpose: On the one hand, nephron-sparing surgery (NSS) in small renal tumors is a safe and effective alternative to radical nephrectomy. On the other hand, the role of preoperative percutaneous needle biopsies (PNB) remains controversial. The purpose of this study was to evaluate the

  7. Needle path planning and steering in a three-dimensional non-static environment using two-dimensional ultrasound images

    Science.gov (United States)

    Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak

    2015-01-01

    Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600

  8. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  9. Surgical technique of percutaneous iliosacral screw fixation in S3 level in unstable pelvic fracture with closed degloving injury and morrell lavallee lesion: Two case reports

    Directory of Open Access Journals (Sweden)

    Ismail H. Dilogo

    2017-01-01

    Conclusions: Percutaneous screw fixation at the level of S3 is feasible and can be inserted in S3 level by sacroiliac type and sacral type with minimal soft tissue intervention and good functional outcome.

  10. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  11. Teleoperation of steerable flexible needles by combining kinesthetic and vibratory feedback.

    Science.gov (United States)

    Pacchierotti, Claudio; Abayazid, Momen; Misra, Sarthak; Prattichizzo, Domenico

    2014-01-01

    Needle insertion in soft-tissue is a minimally invasive surgical procedure that demands high accuracy. In this respect, robotic systems with autonomous control algorithms have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and responsibility, autonomous robotic control is often not desirable. Therefore, it is necessary to focus also on techniques enabling clinicians to directly control the motion of the surgical tools. In this work, we address that challenge and present a novel teleoperated robotic system able to steer flexible needles. The proposed system tracks the position of the needle using an ultrasound imaging system and computes needle's ideal position and orientation to reach a given target. The master haptic interface then provides the clinician with mixed kinesthetic-vibratory navigation cues to guide the needle toward the computed ideal position and orientation. Twenty participants carried out an experiment of teleoperated needle insertion into a soft-tissue phantom, considering four different experimental conditions. Participants were provided with either mixed kinesthetic-vibratory feedback or mixed kinesthetic-visual feedback. Moreover, we considered two different ways of computing ideal position and orientation of the needle: with or without set-points. Vibratory feedback was found more effective than visual feedback in conveying navigation cues, with a mean targeting error of 0.72 mm when using set-points, and of 1.10 mm without set-points.

  12. Insertion Modeling and Its Applications

    OpenAIRE

    Alexander Letichevsky; Oleksandr Letychevskyi; Vladimir Peschanenko

    2016-01-01

    The paper relates to the theoretical and practical aspects of insertion modeling. Insertion modeling is a theory of agents and environments interaction where an environment is considered as agent with a special insertion function. The main notions of insertion modeling are presented. Insertion Modeling System is described as a tool for development of different kinds of insertion machines. The research and industrial applications of Insertion Modeling System are presented.

  13. Percutaneous radiofrequency ablation of lung metastases from colorectal carcinoma under C-arm cone beam CT guidance.

    Science.gov (United States)

    Amouyal, G; Pernot, S; Déan, C; Cholley, B; Scotté, F; Sapoval, M; Pellerin, O

    2017-11-01

    The aim of this study was to assess the feasibility, safety and efficacy of percutaneous radiofrequency ablation of lung metastases from colorectal carcinoma using C-arm cone beam computed tomography (CBCT) guidance. This single-center prospective observational study was performed from August 2013 to August 2016, and included consecutive patients referred for radiofrequency ablation of lung metastases from colorectal cancer. Radiofrequency ablation procedures were performed under C-arm CBCT guidance. Feasibility was assessed by probe accuracy placement, time to accurate placement and number of C-arm CBCT acquisitions to reach the target lesion. Safety was assessed by the report of adverse event graded using the common terminology criteria for adverse events (CTCAE-V4.0). Efficacy was assessed by metastases response rate using RECIST 1.1 and 18 FDG-PET-CT tumor uptake at 6months. Fifty-four consecutive patients (32 men, 22 women) with a mean age of 63±8 (SD) years (range: 51-81years) with a total of 56 lung metastasis from colorectal metastases were treated in a single session. The mean tumor diameter was 25.6±4.5 (SD)mm (range: 17-31mm). Median time to insert the needle into the target lesion was 10min (range: 5-25min). Median number of needles repositioning and C-arm CBCT acquisition per patient was 1 (range: 0-3) and 4 (range: 3-6) respectively. The accuracy for radiofrequency ablation probe placement was 2±0.2 (SD)mm (range: 0-9mm). Pneumothorax requiring chest tube placement occurred in one patient (CTCAE-V4.0 grade 3). At 6months, all patients were alive with tumor response rate of -27% and had no significant activity on the 18 FDG-PET CT follow-up. Percutaneous radiofrequency ablation of lung metastases from colorectal cancer under C-arm CBCT guidance is feasible and safe, with immediate and short-term results similar to those obtained using conventional CT guidance. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS

  14. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    Science.gov (United States)

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian motion module. The needle driver provides needle cannula translation and rotation (2-DOF) and stylet translation (1-DOF). A custom robot controller consisting of multiple piezoelectric motor drivers provides precision closed-loop control of piezoelectric motors and enables simultaneous robot motion and MR imaging. The developed modular robot control interface software performs image-based registration, kinematics calculation, and exchanges robot commands and coordinates between the navigation software and the robot controller with a new implementation of the open network communication protocol OpenIGTLink. Comprehensive compatibility of the robot is evaluated inside a 3-Tesla MRI scanner using standard imaging sequences and the signal-to-noise ratio (SNR) loss is limited to 15%. The image deterioration due to the present and motion of robot demonstrates unobservable image interference. Twenty-five targeted needle placements inside gelatin phantoms utilizing an 18-gauge ceramic needle demonstrated 0.87 mm root mean square (RMS) error in 3D Euclidean distance based on MRI volume segmentation of the image-guided robotic needle placement procedure. PMID:26412962

  15. Driven Around the Bend: Novel Use of a Curved Steerable Needle

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Darra T., E-mail: darra.murphy@vch.ca; Korzan, Jeffrey R.; Ouellette, Hugue A.; Liu, David M. [Vancouver General Hospital, Department of Radiology (Canada); Clarkson, Paul W. [Vancouver General Hospital, Department of Orthopedic Surgery (Canada); Munk, Peter L. [Vancouver General Hospital, Department of Radiology (Canada)

    2013-04-15

    This technical note describes the novel use of a curved, steerable needle to access symptomatic osseous lesions in the pelvis and sacrum for palliative percutaneous treatment that would otherwise be difficult to treat using conventional straight needles. Seven patients with lytic bone lesions were treated. One patient had multiple myeloma; the remaining had metastatic disease: breast carcinoma (n = 2), colorectal carcinoma (n = 1), renal cell carcinoma (n = 1), squamous cell carcinoma (n = 1), and leiomyosarcoma (n = 1). Five of the seven patients had lesions in the posterior acetabulum, and the two other patients had lesions in the sacrum. Four of the seven patients received radiofrequency ablation followed by cementoplasty; three patients received cementation alone. We used a novel needle designed for vertebroplasty, which has an articulating tip allowing it to be guided into lytic bone lesions located in difficult-to-access regions of the pelvis and sacrum. All patients were successfully treated with cementoplasty either with or without thermal ablation. No serious adverse events were reported. The needle was difficult to withdraw in two patients. Steerable curved needles can be successfully used to treat lytic osseous metastases with cementoplasty when lesions are located in sites that may be difficult to reach using conventional straight needles.

  16. Percutaneous lumbar discectomy

    International Nuclear Information System (INIS)

    Xiao Chengjiang; Su Huanbin; Xu Sui; He Xiaofeng; Li Yanhao

    2004-01-01

    Objective: To probe the therapeutic effects, indications and safety of the percutaneous lumbar discectomy (PLDP). Methods: To ameliorate percutaneous punctured route based on classic PLD and modified jaw structure of pulpiform nacleus forceps, with statistic analysis of the therapeutic results of 352 cases of patient undergone PLDP and follow up ranging from 6 to 38 months retrospectively. Results: The effective ratios were excellent in 45.5%, good for 45.4% and bad in 9.1%. 44 of 352 cases with pulps prolapse were cured. No intervertebral inflammation and paradisc hematoma took place. One case complicated with cauda equina injury and 4 cases with appliances broken inside the disc. Conclusions: PLDP is effective and safe, not only adaptive to the contained disc herniation, but also for noncontained herniation. (authors)

  17. Ameliorative percutaneous lumbar discectomy

    International Nuclear Information System (INIS)

    Xiao Chengjiang; Su Huanbin; He Xiaofeng; Li Yanhao

    2005-01-01

    Objective: To ameliorate the percutaneous lumbar discectomy (APLD) for improving the effectiveness and amplifying the indicative range of PLD. Methods: To ameliorate percutaneous punctured route based on classic PLD and discectomy of extracting pulp out of the herniated disc with special pulpforceps. The statistical analysis of the therapeutic results on 750 disc protrusions of 655 cases undergone APLD following up from 6 to 54 months retrospectively. Results: The effective ratios were excellent in 40.2%, good for 46.6% and bad of 13.3%. No occurrance of intervertebral inflammation and paradiscal hematoma, there were only 1 case complicated with injuried cauda equina, and 4 cases with broken appliance within disc. Conclusions: APLD is effective and safe, not only indicative for inclusion disc herniation, but also for noninclusion herniation. (authors)

  18. Percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Przybojewski, J.Z.; Weich, H.F.H.

    1984-01-01

    The purpose of this article is to review PTCA, percutaneous transluminal coronary angioplasty, which can be considered to be a truly revolutionary and fairly simple invasive form of intervention to atherosclerotic obstruction. The 'epidemic' of IHD, ischaemic heart disease, in the Republic of South Africa calls for the employment of this technique, which has already been carried out in a few teaching hospitals in this country. Very recently, modified balloon dilatation catheters have been used percutaneously in the non-operative transluminal correction of congenital coarctation of the aorta in infants and children, congenital pulmonary value stenosis, and hypoplasia and stenosis of the pulmonary arteries. It has also been employed for PTCA and for the simultaneous occlusion of coronary-bronchial artery anastomosis using a detachable balloon. The isotopes thallium 201 and technetium 99 were also used in scintiscanning

  19. Analgesic efficacy of peritubal infiltration of ropivacaine versus ropivacaine and morphine in percutaneous nephrolithotomy under ultrasonic guidance

    Directory of Open Access Journals (Sweden)

    Geeta P Parikh

    2013-01-01

    Full Text Available Background and Purpose: Percutaneous nephrolithotomy is a safe and effective endourologic procedure which is less morbid than open surgery. However, pain around a nephrostomy tube requires good post-operative analgesia. We hypothesize that infiltration of local anesthetic with opioid from the renal capsule to the skin around the nephrostomy tract under ultrasonic guidance would alleviate the postoperative pain for a long period. Methods: A total of 60 ASA physical status I to II patients were selected for a prospective randomized double-blind controlled study in percutaneous nephrolithotomy surgeries. Patients were divided into group R (n=30 and group RM (n=30. Balanced general anesthesia was given. After completion of the surgical procedure, a 23-gauze spinal needle was inserted at 6 and 12 O′clock position under ultrasonic guidance up to renal capsule along the nephrostomy tube. A 10 ml drug solution was infiltrated in each tract while withdrawing from renal capsule to the skin. After extubation, the patient was shifted to the post-anesthesia care unit for 24 hours. Post-operative pain was assessed using the visual analog scale (VAS and dynamic visual analog scale (DVAS (during deep breathing and coughing rating 0-10 for initial 24 hours. Rescue analgesia was given in the form of injection tramadol 1.0 mg/kg intravenously when VAS ≥4 and maximum up to 400 mg in 24 hours. Time to 1 st rescue analgesic, number of doses of tramadol and total consumption of tramadol required in initial 24 hours were noted. Patients were observed for any side effect and treated accordingly. Results: Time to 1 st rescue analgesic, i.e., duration of analgesia in group RM is more prolonged than group R (P=0.0004. The number of doses of tramadol in 24 hours in group R were higher as compared to group RM (P=0.0003. The total amount of tramadol in 24 hours in group R was more than in group RM (P=0.0013. Side effects like nausea and vomiting and sedation were

  20. Detection of Membrane Puncture with Haptic Feedback using a Tip-Force Sensing Needle.

    Science.gov (United States)

    Elayaperumal, Santhi; Bae, Jung Hwa; Daniel, Bruce L; Cutkosky, Mark R

    2014-09-01

    This paper presents calibration and user test results of a 3-D tip-force sensing needle with haptic feedback. The needle is a modified MRI-compatible biopsy needle with embedded fiber Bragg grating (FBG) sensors for strain detection. After calibration, the needle is interrogated at 2 kHz, and dynamic forces are displayed remotely with a voice coil actuator. The needle is tested in a single-axis master/slave system, with the voice coil haptic display at the master, and the needle at the slave end. Tissue phantoms with embedded membranes were used to determine the ability of the tip-force sensors to provide real-time haptic feedback as compared to external sensors at the needle base during needle insertion via the master/slave system. Subjects were able to determine the position of the embedded membranes with significantly better accuracy using FBG tip feedback than with base feedback using a commercial force/torque sensor (p = 0.045) or with no added haptic feedback (p = 0.0024).

  1. Kalman filter-based EM-optical sensor fusion for needle deflection estimation.

    Science.gov (United States)

    Jiang, Baichuan; Gao, Wenpeng; Kacher, Daniel; Nevo, Erez; Fetics, Barry; Lee, Thomas C; Jayender, Jagadeesan

    2018-04-01

    In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle's tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects. In this paper, measurements data from an optical sensor at the needle base and a magnetic resonance (MR) gradient field-driven electromagnetic (EM) sensor placed 10 cm from the needle tip are used within a model-integrated Kalman filter-based sensor fusion scheme. Bending model-based estimations and EM-based direct estimation are used as the measurement vectors in the Kalman filter, thus establishing an online estimation approach. Static tip bending experiments show that the fusion method can reduce the mean error of the tip position estimation from 29.23 mm of the optical sensor-based approach to 3.15 mm of the fusion-based approach and from 39.96 to 6.90 mm, at the MRI isocenter and the MRI entrance, respectively. This work established a novel sensor fusion scheme that incorporates model information, which enables real-time tracking of needle deflection with MRI compatibility, in a free-hand operating setup.

  2. [Special penetration needling for refractory peripheral facial paralysis].

    Science.gov (United States)

    Cao, Rongjuan; Qiu, Xiaohu; Xie, Xiaokun

    2018-03-12

    To observe the clinical effect difference between special penetration needling and conventional penetration needling for the refractory peripheral facial paralysis. A total of 97 patients with intractable facial paralysis were randomized into an observation group (49 cases and 2 dropping) and a control group (48 cases and 4 dropping). In the observation group, special penetration needling at an angle about 45° between the penetration needle and paralysis muscle bundle was used, Yangbai (GB 14) through Touwei (ST 8), Yangbai (GB 14) through Shangxing (GV 23), Sizhukong (TE 23) through Yuyao (EX-HN 4), Qianzhen (Extra) through Yingxiang (LI 20), mutual penetration between Yingxiang (LI 20) and Jiache (ST 6). Conventional penetration needling was applied in the control group, Yangbai (GB 14) through Yuyao (EX-HN 4), Cuanzhu (BL 2) through Yuyao (EX-HN 4), mutual penetration between Dicang (ST 4) and Jiache (ST 6), Qianzheng (Extra) through Dicang (ST 4), Sibai (ST 2) through Yingxiang (LI 20). Three groups of electroacupuncture (discontinuous wave, 1 Hz) with tolerance were connected respectively in the two groups, Yangbai (GB 14) and Sizhukong (TE 23), Yangbai (GB 14) and Qianzheng (Extra), Yingxiang (LI 20) and Jiache (ST 6) in the observation group, Yangbai (GB 14) and Cuanzhu (BL 2), Dicang (ST 4) and Jiache (ST 6), Qianzheng (Extra) and Sibai (ST 2) in the control group. TDP was applied in the two groups at the affected Yifeng (TE 17), Jiache (ST 6) and Qianzheng (Extra), which were around the ear. Perpendicular insertion was used at Yifeng (TE 17) at the affected side and Hegu (LI 4) at the healthy side and bilateral Zusanli (ST 36). The needles were retained for 30 min. The treatment was given for 3 courses, once a day and 10 days as a course, 5 days at the interval. House-Brackmann (H-B) facial nerve grading score was recorded before and after treatment. The clinical effects were compared. The H-B scores after treatment in the two groups were higher than

  3. Automatic path proposal computation for CT-guided percutaneous liver biopsy.

    Science.gov (United States)

    Helck, A; Schumann, C; Aumann, J; Thierfelder, K; Strobl, F F; Braunagel, M; Niethammer, M; Clevert, D A; Hoffmann, R T; Reiser, M; Sandner, T; Trumm, C

    2016-12-01

    To evaluate feasibility of automatic software-based path proposals for CT-guided percutaneous biopsies. Thirty-three patients (60 [Formula: see text] 12 years) referred for CT-guided biopsy of focal liver lesions were consecutively included. Pre-interventional CT and dedicated software (FraunhoferMeVis Pathfinder) were used for (semi)automatic segmentation of relevant structures. The software subsequently generated three path proposals in downward quality for CT-guided biopsy. Proposed needle paths were compared with consensus proposal of two experts (comparable, less suitable, not feasible). In case of comparable results, equivalent approach to software-based path proposal was used. Quality of segmentation process was evaluated (Likert scale, 1 [Formula: see text] best, 6 [Formula: see text] worst), and time for processing was registered. All biopsies were performed successfully without complications. In 91 % one of the three automatic path proposals was rated comparable to experts' proposal. None of the first proposals was rated not feasible, and 76 % were rated comparable to the experts' proposal. 7 % automatic path proposals were rated not feasible, all being second choice ([Formula: see text]) or third choice ([Formula: see text]). In 79 %, segmentation at least was good. Average total time for establishing automatic path proposal was 42 [Formula: see text] 9 s. Automatic software-based path proposal for CT-guided liver biopsies in the majority provides path proposals that are easy to establish and comparable to experts' insertion trajectories.

  4. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    Science.gov (United States)

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  5. Clarification of the characteristics of needle-tip movement during vacuum venipuncture to improve safety

    Directory of Open Access Journals (Sweden)

    Fujii C

    2013-07-01

    Full Text Available Chieko FujiiFaculty of Nursing and Medical Care, Keio University, Kanagawa, JapanBackground: Complications resulting from venipuncture include vein and nerve damage, hematoma, and neuropathic pain. Although the basic procedures are understood, few analyses of actual data exist. It is important to improve the safety standards of this technique during venipuncture. This study aimed to obtain data on actual needle movement during vacuum venipuncture in order to develop appropriate educational procedures.Methods: Six experienced nurses were recruited to collect blood samples from 64 subjects. These procedures were recorded using a digital camera. Software was then used to track and analyze motion without the use of a marker in order to maintain the sterility of the needle. Movement along the X- and Y-axes during blood sampling was examined.Results: Approximately 2.5 cm of the needle was inserted into the body, of which 6 mm resulted from advancing or moving the needle following puncture. The mean calculated puncture angle was 15.2°. Given the hazards posed by attaching and removing the blood collection tube, as well as by manipulating the needle to fix its position, the needle became unstable whether it was fixed or not fixed.Conclusion: This study examined venipuncture procedures and showed that the method was influenced by increased needle movement. Focusing on skills for puncturing the skin, inserting the needle into the vein, and changing hands while being conscious of needle-tip stability may be essential for improving the safety of venipuncture.Keywords: blood collection, nerve damage, motion analysis, patient safety, puncture angle, clinical education

  6. Study on design and cutting parameters of rotating needles for core biopsy.

    Science.gov (United States)

    Giovannini, Marco; Ren, Huaqing; Cao, Jian; Ehmann, Kornel

    2018-06-15

    Core needle biopsies are widely adopted medical procedures that consist in the removal of biological tissue to better identify a lesion or an abnormality observed through a physical exam or a radiology scan. These procedures can provide significantly more information than most medical tests and they are usually performed on bone lesions, breast masses, lymph nodes and the prostate. The quality of the samples mainly depends on the forces exerted by the needle during the cutting process. The reduction of these forces is critical to extract high-quality tissue samples. The most critical factors that affect the cutting forces are the geometry of the needle tip and its motion while it is penetrating the tissue. However, optimal needle tip configurations and cutting parameters are not well established for rotating insertions. In this paper, the geometry and cutting forces of hollow needles are investigated. The fundamental goal of this study is to provide a series of guidelines for clinicians and surgeons to properly select the optimal tip geometries and speeds. Analytical models related to the cutting angles of several needle tip designs are presented and compared. Several needle tip geometries were manufactured from a 14-gauge cannula, commonly adopted during breast biopsies. The needles were then tested at different speeds and on different phantom tissues. According to these experimental measurements recommendations were formulated for rotating needle insertions. The findings of this study can be applied and extended to several biopsy procedures in which a cannula is used to extract tissue samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Successful endovascular treatment of a hemodialysis graft pseudoaneurysm by covered stent and direct percutaneous thrombin injection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-07-25

    Vascular access for hemodialysis remains a challenge for nephrologists, vascular surgeons, and interventional radiologists alike. Arteriovenous fistula and synthetic grafts remain the access of choice for long-term hemodialysis; however, they are subject to complications from infection and repeated needle cannulation. Pseudoaneurysms are an increasingly recognized adverse event. At present, there are many minimally invasive methods to repair these wall defects. We present a graft pseudoaneurysm, which required a combination of endovascular stent graft placement and percutaneous thrombin injection for successful occlusion.

  8. Percutaneous vertebroplasty for eosinophilic granuloma of the cervical spine in a child

    International Nuclear Information System (INIS)

    Tan, Hua-Qiao; Li, Ming-Hua; Wu, Chun-Gen; Gu, Yi-Feng; Zhang, He; Fang, Chun

    2007-01-01

    We report a case of eosinophilic granuloma at the fourth cervical vertebra in a 10-year-old girl presenting with a 1-month history of cervical pain and stiffness. This lesion was histologically diagnosed by needle biopsy and then treated by percutaneous vertebroplasty. After the procedure, the cervical pain and stiffness resolved rapidly. The height of the vertebral body remained stable without further collapse over a 6-month follow-up period. (orig.)

  9. History of Retractor Technologies for Percutaneous Pedicle Screw Fixation Systems.

    Science.gov (United States)

    Mobbs, Ralph J; Phan, Kevin

    2016-02-01

    Minimally invasive techniques aimed at minimizing surgery-associated risk and morbidity of spinal surgery have increased in popularity in recent years. Their potential advantages include reduced length of hospital stay, blood loss, and requirement for post-operative analgesia and earlier return to work. One such minimally invasive technique is the use of percutaneous pedicle screw fixation, which is paramount for promoting rigid and stable constructs and fusion in the context of trauma, tumors, deformity and degenerative disease. Percutaneous pedicle screw insertion can be an intimidating prospect for surgeons who have only been trained in open techniques. One of the ongoing challenges of this percutaneous system is to provide the surgeon with adequate access to the pedicle entry anatomy and adequate tactile or visual feedback concerning the position and anatomy of the rod and set-screw construct. This review article discusses the history and evolution of percutaneous pedicle screw retractor technologies and outlines the advances over the last decade in the rapidly expanding field of minimal access surgery for posterior pedicle screw based spinal stabilization. As indications for percutaneous pedicle screw techniques expand, the nuances of the minimally invasive surgery techniques and associated technologies will also multiply. It is important that experienced surgeons have access to tools that can improve access with a greater degree of ease, simplicity and safety. We here discuss the technical challenges of percutaneous pedicle screw retractor technologies and a variety of systems with a focus on the pros and cons of various retractor systems. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  10. Percutaneous nephrostomy and antegrade ureteral stenting: technique - indications - complications

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, Klaus A. [Klagenfurt General Hospital, Department of Radiology, Klagenfurt (Austria); Portugaller, Horst R. [University Hospital of Graz, Department of Radiology, Graz (Austria)

    2006-09-15

    In this review the technique, indication for and complications of percutaneous nephrostomy (PCN) and antegrade ureter stent insertion are described. In the majority of the cases PCN is performed to relieve urinary obstruction, which can be of benign or malignant nature. Another indication for PCN is for treatment of urinary fistulas. PCN can be performed under ultrasound and/or fluoroscopic guidance, with a success rate of more than 90%. The complication rate is approximately 10% for major and minor complications together and 4-5% for major complications only. Percutaneous antegrade double-J stent insertion usually is performed if retrograde ureter stenting has not been successful. However, especially in malignant obstructions, the success rate for antegrade stenting is higher than for retrograde transvesical double-J stent insertion. In the case of severe infection and bleeding after PCN JJ-stent insertion may be contraindicated so long as there is no sufficient concomitant drainage via a PCN. Lower urinary tract dysfunction should be excluded before stent placement. The complication rate is 2-4%. Consequent stent surveillance with regular stent exchange is mandatory. (orig.)

  11. Clinical application of percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation under CT guidance

    International Nuclear Information System (INIS)

    Wang Linyou; Li Yuan; Shao Yangtong

    2004-01-01

    Objective: To evaluate the effect of the percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation. Methods: 75 cases of lumbar disc herniation with significant clinical signs were confirmed by CT scan. The technique of the percutaneous lumbar puncture led the needle to approach nerve root and injected medicine diffusing into extraduramater, and then relieved the symptom of sciatica. Results: The rate of success of percutaneous lumbar puncture guided by CT reached to 100%. After two weeks of follow-up, the symptom of pain was obviously improved and disappeared in 63.3% cases. There were 23.0% cases needed a second procedure, and no change was obsesved in 9.3% cases. Conclusions: The percutaneous lumbar puncture guided by CT to treat sciatica resulted from lumbar disc herniation is one of the safe, reliable, effective new methods with no complication. The long term effectiveness is still in need of investigation. (authors)

  12. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  13. 21 CFR 880.5580 - Acupuncture needle.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Acupuncture needle. 880.5580 Section 880.5580 Food... § 880.5580 Acupuncture needle. (a) Identification. An acupuncture needle is a device intended to pierce the skin in the practice of acupuncture. The device consists of a solid, stainless steel needle. The...

  14. Needle catheter duodenostomy: a technique for duodenal alimentation of birds.

    Science.gov (United States)

    Goring, R L; Goldman, A; Kaufman, K J; Roberts, C; Quesenberry, K E; Kollias, G V

    1986-11-01

    A technique for duodenal alimentation (needle catheter duodenostomy) of birds was developed, using the domestic pigeon (Columba livia) as the experimental model. A needle catheter was inserted into the descending duodenum of 5 pigeons and was secured to the body wall and dorsum of each bird. A liquid diet was administered daily (in equal amounts of 0, 4, 8, 12, and 16 hours) for 14 days without adverse effects. On day 15, the catheters were removed, and the birds immediately resumed normal consumption of a pigeon ration and water diet. Although 4 of the 5 birds had minor weight loss, dietary alterations probably could be used on an individual basis to alleviate this problem. After oral alimentation was resumed, the 5 birds exceeded their initial body weight within 7 days. Four weeks after catheter removal, positive-contrast radiographic evaluations indicated that the duodenum of each pigeon appeared normal. Needle catheter duodenostomy was a viable method of alimentation in the domestic pigeon. This technique should be applicable for other avian species requiring bypass of the upper gastrointestinal tract proximal to the region of catheter insertion in the duodenum.

  15. Can a virtual reality assessment of fine motor skill predict successful central line insertion?

    Science.gov (United States)

    Mohamadipanah, Hossein; Parthiban, Chembian; Nathwani, Jay; Rutherford, Drew; DiMarco, Shannon; Pugh, Carla

    2016-10-01

    Due to the increased use of peripherally inserted central catheter lines, central lines are not performed as frequently. The aim of this study is to evaluate whether a virtual reality (VR)-based assessment of fine motor skills can be used as a valid and objective assessment of central line skills. Surgical residents (N = 43) from 7 general surgery programs performed a subclavian central line in a simulated setting. Then, they participated in a force discrimination task in a VR environment. Hand movements from the subclavian central line simulation were tracked by electromagnetic sensors. Gross movements as monitored by the electromagnetic sensors were compared with the fine motor metrics calculated from the force discrimination tasks in the VR environment. Long periods of inactivity (idle time) during needle insertion and lack of smooth movements, as detected by the electromagnetic sensors, showed a significant correlation with poor force discrimination in the VR environment. Also, long periods of needle insertion time correlated to the poor performance in force discrimination in the VR environment. This study shows that force discrimination in a defined VR environment correlates to needle insertion time, idle time, and hand smoothness when performing subclavian central line placement. Fine motor force discrimination may serve as a valid and objective assessment of the skills required for successful needle insertion when placing central lines. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Needle Biopsy of the Lung

    Science.gov (United States)

    ... clip. The needle is hollow so it can capture the tissue specimen. There are several types of ... breath, difficulty in catching your breath, rapid pulse (heart rate), sharp chest or shoulder pain with breathing, ...

  17. Needle-free influenza vaccination

    NARCIS (Netherlands)

    Amorij, Jean-Pierre; Hinrichs, Wouter L.J.; Frijlink, Henderik W.; Wilschut, Jan C.; Huckriede, Anke

    2010-01-01

    Vaccination is the cornerstone of influenza control in epidemic and pandemic situations. Influenza vaccines are typically given by intramuscular injection. However, needle-free vaccinations could offer several distinct advantages over intramuscular injections: they are pain-free, easier to

  18. Reactivity insertion accident analysis

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Nakata, H.; Yorihaz, H.

    1990-04-01

    The correct prediction of postulated accidents is the fundamental requirement for the reactor licensing procedures. Accident sequences and severity of their consequences depend upon the analysis which rely on analytical tools which must be validated against known experimental results. Present work presents a systematic approach to analyse and estimate the reactivity insertion accident sequences. The methodology is based on the CINETHICA code which solves the point-kinetics/thermohydraulic coupled equations with weighted temperature feedback. Comparison against SPERT experimental results shows good agreement for the step insertion accidents. (author) [pt

  19. ISABELLE insertion quadrupoles

    International Nuclear Information System (INIS)

    Kaugerts, J.; Polk, I.; Sampson, W.; Dahl, P.F.

    1979-01-01

    Beam focussing and control at the beam intersection regions of ISABELLE is accomplished by a number of superconducting insertion quadrupoles. These magnets differ from the standard ISABELLE quadrupoles in various ways. In particular, the requirements of limited space near the intersections and aperture for beam extraction impose constraints on their configuration. To achieve optimum beam focussing and provide tuning flexibility calls for stronger quadrupole trim windings than those in the standard quadrupoles. The magnetic and mechanical design of the insertion quadrupoles and their associated correction and steering windings to accomplish the above tasks is presented

  20. Postoperative intraabdominal fluid collections : a modified percutaneous drainage method using a surgical drain track

    International Nuclear Information System (INIS)

    Lee, Deok Hee; Kim, Gab Choul; Hwang, Jae Cheol; Yoon, Hyun Ki; Song, Ho Young; Sung, Kyu Bo

    2000-01-01

    In the management of postoperative fluid collection, the conventional percutaneous drainage method can be employed. Because of abdominal incisions and various types of surgical drains and/or T-tubes, the application of this method is not always easy, however. We inserted a drainage catheter through a pre-existing percutaneous track formed by a surgical drain located adjacent to the site of abnormal fluid collection. There was no need to remove the drain nor make an additional puncture in the abdominal wall. A dilator was inserted along the drain, and a guide wire was used to negotiate its intraperitoneal track and reach the accumulated fluid. The procedure was simple and safe. We briefly describe our experience of this modified percutaneous drainage technique, as used in three cases involving postoperative fluid collection. (author)

  1. Single-incision laparoscopic cholecystectomy with needle graspers.

    Science.gov (United States)

    Sumiyoshi, Kinjiro; Sato, Norihiro; Akagawa, Shin; Hirano, Tatsuya; Koikawa, Kazuhiro; Horioka, Kohei; Ozono, Keigo; Fujiwara, Kenji; Tanaka, Masao; Sada, Masayuki

    2012-01-01

    Single-incision laparoscopic cholecystectomy (SILC) is a promising alternative to standard multi-incision laparoscopic cholecystectomy (LC). However, generalization of SILC is still hampered by technical difficulties mainly associated with the lack of trocars used for retraction of the gallbladder. We therefore developed a modified method of SILC with the use of needle graspers (SILC-N) for optimal retraction and exposure. In addition to two trocars inserted through a single transumbilical incision, two needle ports were placed on the right subcostal and lateral abdominal wall, through which needle graspers were used for retraction of the gallbladder. Since December, 2009, 12 patients with symptomatic cholelithiasis were treated by SILC-N. SILC-N was successfully performed in all but one patient requiring a conversion to the 4-port LC with a mean operative time of 71.5 (48-107) minutes. None of the patients experienced intraoperative or postoperative complications. The transumbilical incision and pinholes for needle graspers were almost invisible on discharge. Our preliminary results suggest that SILC-N is a simple, safe and feasible technique of cholecystectomy offering similar postoperative recovery and better cosmetic outcome as compared to conventional LC.

  2. Effects of pore size, implantation time and nano-surface properties on rat skin ingrowth into percutaneous porous titanium implants

    OpenAIRE

    Farrell, Brad J.; Prilutsky, Boris I.; Ritter, Jana M.; Kelley, Sean; Popat, Ketul; Pitkin, Mark

    2013-01-01

    The main problem of percutaneous osseointegrated implants is poor skin-implant integration, which may cause infection. This study investigated the effects of pore size (Small, 40–100 microns and Large, 100–160 microns), nanotubular surface treatment (Nano), and duration of implantation (3 and 6 weeks) on skin ingrowth into porous titanium. Each implant type was percutaneously inserted in the back of 35 rats randomly assigned to 7 groups. Implant extrusion rate was measured w...

  3. Design and principle of operation of the HeartMate PHP (percutaneous heart pump)

    NARCIS (Netherlands)

    Mieghem, N.M. van; Daemen, J.; Uil, C. den; Dur, O.; Joziasse, L.; Maugenest, A.M.; Fitzgerald, K.; Parker, C.; Muller, P.; Geuns, R.J.M. van

    2018-01-01

    The HeartMate PHP (percutaneous heart pump) is a second-generation transcatheter axial flow circulatory support system. The collapsible catheter pump is inserted through a 14 Fr sheath, deployed across the aortic valve expanding to 24 Fr and able to deliver up to 5 L/min blood flow at minimum

  4. Difficulties with percutaneous endoscopic gastrostomy (PEG): a practical guide for the endoscopist.

    LENUS (Irish Health Repository)

    O'Mahony, S

    2013-03-01

    Percutaneous endoscopic gastrostomy (PEG) is a widely used and effective means of providing long-term nutrition in patients with inadequate oral intake. The demand for this intervention has risen steadily since the early 1990s. Endoscopists who perform PEG insertion have become increasingly concerned about inappropriate use of this intervention.

  5. Percutaneous metallic self-expandable endoprostheses in malignant hilar biliary obstruction

    NARCIS (Netherlands)

    Stoker, J.; Laméris, J. S.; van Blankenstein, M.

    1993-01-01

    Forty-five patients with malignant hilar obstruction were treated with a total of 68 percutaneously inserted metallic self-expandable endoprostheses (Wallstents) for palliative biliary drainage. The stent diameter was 1 cm; the length was 3.5 to 10.5 cm. Early complications occurred in seven

  6. Fabrication of tungsten wire needles

    International Nuclear Information System (INIS)

    Roder, A.

    1983-02-01

    Fine point needles for field emissoin are conventionally produced by electrolytically or chemically etching tungsten wire. Points formed in this manner have a typical tip radius of about 0.5 microns and a cone angle of some 30 degrees. The construction of needle matrix detector chambers has created a need for tungsten needles whose specifications are: 20 mil tungsten wire, 1.5 inch total length, 3 mm-long taper (resulting in a cone angle of about 5 degrees), and 25 micron-radius point (similar to that found on sewing needles). In the process described here for producing such needles, tungsten wire, immersed in a NaOH solution and in the presence of an electrode, is connected first to an ac voltage and then to a dc supply, to form a taper and a point on the end of the wire immersed in the solution. The process parameters described here are for needles that will meet the above specifications. Possible variations will be discussed under each approprite heading

  7. Method of inserting fuel rod

    International Nuclear Information System (INIS)

    Kamimoto, Shuji; Imoo, Makoto; Tsuchida, Kenji.

    1991-01-01

    The present invention concerns a method of inserting a fuel rod upon automatic assembling, automatic dismantling and reassembling of a fuel assembly in a light water moderated reactor, as well as a device and components used therefor. That is, a fuel rod is inserted reliably to an aimed point of insertion by surrounding the periphery of the fuel rod to be inserted with guide rods, and thereby suppressing the movement of the fuel rod during insertion. Alternatively, a fuel rod is inserted reliably to a point of insertion by inserting guide rods at the periphery of the point of insertion for the fuel rod to be inserted thereby surrounding the point of insertion with the guide rods or fuel rods. By utilizing fuel rods already present in the fuel assembly as the guide rods described above, the fuel rod can be inserted reliably to the point of insertion with no additional devices. Dummy fuel rods are previously inserted in a fuel assembly which are then utilized as the above-mentioned guide rods to accurately insert the fuel rod to the point of insertion. (I.S.)

  8. Teleoperation of steerable flexible needles by combining kinesthetic and vibratory feedback

    NARCIS (Netherlands)

    Jones, L.; Pacchierotti, Claudio; Abayazid, Momen; Misra, Sarthak; Prattichizzo, Domenico

    2014-01-01

    Needle insertion in soft-tissue is a minimally invasive surgical procedure that demands high accuracy. In this respect, robotic systems with autonomous control algorithms have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and responsibility,

  9. Insertion in Persian

    Science.gov (United States)

    Kambuziya, Aliyeh Kord-e Zafaranlu; Dehghan, Masoud

    2011-01-01

    This paper investigates epenthesis process in Persian to catch some results in relating to vowel and consonant insertion in Persian lexicon. This survey has a close relationship to the description of epenthetic consonants and the conditions in which these consonants are used. Since no word in Persian may begin with a vowel, so that hiatus can't be…

  10. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  11. CT guided percutaneous renal cysts puncture with ethanol therapy

    International Nuclear Information System (INIS)

    Zhang Xuezhe; Lu Yan; Wang Wu; Huang Zhengguo; Ren An

    2002-01-01

    Objective: To analyse our clinical experience with CT guided percutaneous renal cysts puncture and ethanol therapy. Methods: Five hundred and ten renal cysts in 445 patients were undergone CT guided percutaneous renal cysts puncture and ethanol therapy. Among the 445 cases, 385 cases had solitary renal cyst, 53 multiple renal cysts, and 7 polycystic kidneys. The renal cysts varied in size from 1.9 to 13.5 cm in diameter. The amount of aspirated fluid varied from 3 to 780 ml. A 18-21 gauge aspiration needles were used for all patients. A 25.0% cyst volume replacement with 99.7% ethanol was approved to be appropriate. Results: 427 renal cysts in 396 patients were followed up by computed tomographic (CT) or ultrasound for less than 3 months to more than one year duration. The curative effective rate and disappearance rate of the renal cystic cavity in solitary renal cysts were 97% and 82%, respectively. In multiple renal cysts, the corresponding values were 95% and 79%. In polycystic kidneys, the curative rate was 67%. The complications such as local abdominal pain (28 cases) and hematuria (four cases) were observed in this series. There were no fatal complications. Conclusions: CT guided percutaneous renal cyst puncture and ethanol therapy is an useful procedure for the treatment of solitary renal cysts and multiple renal cysts

  12. Percutaneous Augmented Peripheral Osteoplasty in Long Bones of Oncologic Patients for Pain Reduction and Prevention of Impeding Pathologic Fracture: The Rebar Concept

    International Nuclear Information System (INIS)

    Kelekis, A.; Filippiadis, D.; Anselmetti, G.; Brountzos, E.; Mavrogenis, A.; Papagelopoulos, P.; Kelekis, N.; Martin, J.-B.

    2016-01-01

    PurposeTo evaluate clinical efficacy/safety of augmented peripheral osteoplasty in oncologic patients with long-term follow-up.Materials and MethodsPercutaneous augmented peripheral osteoplasty was performed in 12 patients suffering from symptomatic lesions of long bones. Under extensive local sterility measures, anesthesiology care, and fluoroscopic guidance, direct access to lesion was obtained and coaxially a metallic mesh consisting of 25–50 medical grade stainless steel micro-needles (22 G, 2–6 cm length) was inserted. PMMA for vertebroplasty was finally injected under fluoroscopic control. CT assessed implant position 24-h post-treatment.ResultsClinical evaluation included immediate and delayed follow-up studies of patient’s general condition, NVS pain score, and neurological status. Imaging assessed implant’s long-term stability. Mean follow-up was 16.17 ± 10.93 months (range 2–36 months). Comparing patients’ scores prior (8.33 ± 1.67 NVS units) and post (1.42 ± 1.62 NVS units) augmented peripheral osteoplasty, there was a mean decrease of 6.92 ± 1.51 NVS units. Overall mobility improved in 12/12 patients. No complication was observed.ConclusionPercutaneous augmented peripheral osteoplasty (rebar concept) for symptomatic malignant lesions in long bones seems to be a possible new technique for bone stabilization. This combination seems to provide necessary stability against shearing forces applied in long bones during weight bearing

  13. Percutaneous Augmented Peripheral Osteoplasty in Long Bones of Oncologic Patients for Pain Reduction and Prevention of Impeding Pathologic Fracture: The Rebar Concept

    Energy Technology Data Exchange (ETDEWEB)

    Kelekis, A., E-mail: akelekis@med.uoa.gr; Filippiadis, D., E-mail: dfilippiadis@yahoo.gr [University General Hospital “ATTIKON”, 2nd Radiology Department (Greece); Anselmetti, G., E-mail: gc.anselmetti@fastwebnet.it [GVM Care and Research Maria Pia Hospital (Italy); Brountzos, E., E-mail: ebrountz@med.uoa.gr [University General Hospital “ATTIKON”, 2nd Radiology Department (Greece); Mavrogenis, A., E-mail: afm@otenet.gr; Papagelopoulos, P., E-mail: pjp@hol.gr [University General Hospital “ATTIKON”, A Orthopedic Clinic (Greece); Kelekis, N., E-mail: kelnik@med.uoa.gr [University General Hospital “ATTIKON”, 2nd Radiology Department (Greece); Martin, J.-B., E-mail: jbmartin@cird.ch [Centre Imaginerie Rive Droite & Gauche (Switzerland)

    2016-01-15

    PurposeTo evaluate clinical efficacy/safety of augmented peripheral osteoplasty in oncologic patients with long-term follow-up.Materials and MethodsPercutaneous augmented peripheral osteoplasty was performed in 12 patients suffering from symptomatic lesions of long bones. Under extensive local sterility measures, anesthesiology care, and fluoroscopic guidance, direct access to lesion was obtained and coaxially a metallic mesh consisting of 25–50 medical grade stainless steel micro-needles (22 G, 2–6 cm length) was inserted. PMMA for vertebroplasty was finally injected under fluoroscopic control. CT assessed implant position 24-h post-treatment.ResultsClinical evaluation included immediate and delayed follow-up studies of patient’s general condition, NVS pain score, and neurological status. Imaging assessed implant’s long-term stability. Mean follow-up was 16.17 ± 10.93 months (range 2–36 months). Comparing patients’ scores prior (8.33 ± 1.67 NVS units) and post (1.42 ± 1.62 NVS units) augmented peripheral osteoplasty, there was a mean decrease of 6.92 ± 1.51 NVS units. Overall mobility improved in 12/12 patients. No complication was observed.ConclusionPercutaneous augmented peripheral osteoplasty (rebar concept) for symptomatic malignant lesions in long bones seems to be a possible new technique for bone stabilization. This combination seems to provide necessary stability against shearing forces applied in long bones during weight bearing.

  14. Needle localization using a moving stylet/catheter in ultrasound-guided regional anesthesia: a feasibility study

    Science.gov (United States)

    Beigi, Parmida; Rohling, Robert

    2014-03-01

    Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.

  15. Single-Pass Percutaneous Liver Biopsy for Diffuse Liver Disease Using an Automated Device: Experience in 154 Procedures

    International Nuclear Information System (INIS)

    Rivera-Sanfeliz, Gerant; Kinney, Thomas B.; Rose, Steven C.; Agha, Ayad K.M.; Valji, Karim; Miller, Franklin J.; Roberts, Anne C.

    2005-01-01

    Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to home after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted

  16. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  17. Ultrasound guided peritubal infiltration of 0.25% Bupivacaine versus 0.25% Ropivacaine for postoperative pain relief after percutaneous nephrolithotomy: A prospective double blind randomized study

    Directory of Open Access Journals (Sweden)

    Geeta P Parikh

    2014-01-01

    Full Text Available Background and Aim: Percutaneous nephrolithotomy (PCNL is a common for managing renal calculi. Pain in the initial post operatie period is relieved by infiltration of local anaesthetic around the nephrostomy tract.We aimed to compare the analgesic efficacy of bupivacaine and ropivacaine. Methods: A total of 100 adult patients undergoing elective PCNL- under balanced general anaesthesia were randomly divided into bupivacaine group (Group B and ropivacaine group (Group R. After completion of procedure, 23G spinal needle was inserted at 6 and 12 O′clock position under ultrasonic guidance up to renal capsule along the nephrostomy tube. A volume of 10 ml of either 0.25% bupivacaine or 0.25% ropivacaine solution was infiltrated in each tract while withdrawing the needle. Post-operative pain was assessed using visual analogue scale (VAS and dynamic visual analogue scale (D-VAS for initial 24 h. Intravenous tramadol was given as rescue analgesia when VAS >4. Time to first rescue analgesic, number of doses and total amount of tramadol required in initial 24 h and side-effects were noted. Results: Visual analogue scale and D-VAS at 6 h and 8 h in Group B was significantly higher than Group R. Mean time to first rescue analgesia in Group R was significantly longer than Group B. Mean number of doses of tramadol and total consumption of tramadol in 24 h was less in Group R, though not statistically significant. Conclusion: Peritubal infiltration of 0.25% ropivacaine infiltration along the nephrostomy tract is more effective than 0.25% bupivacaine in alleviating initial post-operative pain after PCNL.

  18. [Ultrasound guided percutaneous nephrolithotripsy].

    Science.gov (United States)

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  19. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  20. CT-guided percutaneous treatment of osteoid osteoma

    International Nuclear Information System (INIS)

    Mazoyer, J.F.; Kohler, R.; Bossard, D.

    1990-01-01

    The authors of this paper report seven cases of percutaneous destruction of osteoid osteoma. All patients complained of typical pain lasting for several months. In each case, finding of plain radiography, bone scintigraphy, and CT were strongly suggestive of an osteoid osteoma. All the lesions were located on the lower limb (five femoral and two tibial). Under general anesthesia, the nidus was drilled through a trocar inserted percutaneously with CT guidance. Patients were discharged 1-3 days after the procedure with no residual pain, and they are still asymptomatic 18-33 months later, with normal scintigraphic and CT studies. Histologic confirmation was allowed by technical improvement of the method in the last four cases

  1. Percutaneous antegrade ureteric stent removal using a rigid alligator forceps.

    LENUS (Irish Health Repository)

    Given, M F

    2008-12-01

    To evaluate the safety and efficacy of percutaneous antegrade ureteric stent removal using a rigid alligator forceps. Twenty patients were included in our study. Indications for ureteric stent insertion included stone disease (n = 7), malignancy (n = 8) and transplant anastomotic strictures (n = 5). Stent retrieval was carried out for proximal stent placement\\/migration in seven patients and encrustation in the remaining 13. Twenty-two stents were successfully retrieved in 20 patients. There was one technical failure (5%). There were no major complications. We had four minor complications, which included nephrostomy site pain (n = 2), periprocedural sepsis (n = 1) and a small urinoma (n = 1). All patients settled with conservative management. Percutaneous radiologically guided antegrade ureteric stent removal with an alligator forceps is safe and effective, particularly when initial surgical removal has failed.

  2. A feasibility of single-incision laparoscopic percutaneous extraperitoneal closure for treatment of incarcerated inguinal hernia in children: our preliminary outcome and review of the literature.

    Science.gov (United States)

    Murase, Naruhiko; Uchida, Hiroo; Seki, Takashi; Hiramatsu, Kiyoshi

    2016-02-01

    The purpose of this study is to examine the feasibility of single-incision laparoscopic percutaneous extraperitoneal closure (LPEC) for incarcerated inguinal hernia (IIH) repair. 6 single-incision LPEC procedures were performed for IIH repair and 60 procedures were performed for reducible inguinal hernia (RIH) in the same period of time in one hospital. The laparoscope and one pair of grasping forceps were placed through the same umbilical incision. In IIH repair, the herniated organ was gently pulled using the grasping forceps with external manual pressure. If it was difficult to reduce the herniated organ with one pair of forceps, another pair of forceps were inserted through a multi-channel port without extending the umbilical incidion. Using the LPEC needle, the hernia orifice was closed extraperitoneally. We performed a retrospective analysis to compare the outcomes of single-incision LPEC for IIH repair or reducible inguinal hernia. All procedures were completed by single-incision without open conversion. A multi-channel port with another pair of forceps was needed in three cases. The operation time and the length of stay were significantly longer with IIH repair than with RIH repair. There were no major complications and there was no evidence of early recurrence in any patient. In conclusion, single-incision LPEC with a multi-channel port is feasible and safe for IIH repair.

  3. Fuel insert shuffler

    International Nuclear Information System (INIS)

    Naser, J.; Colley, R.; Gaiser, J.; Brookmire, T.; Engle, S.

    1987-01-01

    The potential for the use of expert systems in the nuclear power industry is widely recognized. The benefits of such systems include consistency of reasoning during off-normal situations when humans are under great stress, the reduction of time required to perform certain functions and the retention of human expertise in performing specialized functions. As the potential benefits are more and more demonstrated and realized, the development of expert systems becomes a necessary part of the nuclear power industry. The development of the fuel insert shuffle expert system is used as a case study. In fact, it shows that the potential benefits are realizable. Currently, the development of the insert shuffle plan requires three to four man-weeks of effort. Further modifications to this plan are sometimes required dur to either changes in the desired core load pattern or damaged fuel assemblies or inserts. These changes generally require two to four man-days of effort and could be stressful if they are critical path items on the outage schedule

  4. Percutaneous transhepatic cholangiography: analysis of 120 cases

    International Nuclear Information System (INIS)

    Sohn, Hyung Sun; Shin, Kyung Sub; Kang, Hyo Seok

    1981-01-01

    Percutaneous transhepatic cholangiography (PTC) is of value in differential diagnosis of cholestatic diseases. Authors had performed PTC in 120 patients with flexible needle of 23 gauge at the Department of Radiology, Kang Nam St. Mary's Hospital and Myung Dong St. Mary's Hospital during the period from January, 1976 to April, 1980. PTC was accomplished successfully in 112 of 120 patients. Diagnoses included cholangiocarcinomas (27 cases), carcinomas of pancreas head (21 cases), ampullary carcinomas (4 cases), metastatic carcinomas (5 cases), bile duct stones (27 cases), sclerosing cholangitis (6 cases), hepatitis (6 cases), liver cirrhosis (6 cases), post operative adhesions (5 cases), chronic pancreatitis (3 cases), stomach carcinomas (3 cases), clonorchiasis (2 cases), blood clot (1 case), and remaining normal 4 cases. Some characteristic PTC findings were: (1) segmental annular narrowing and abrupt complete obstruction and polyploid filling defects of the bile duct in cholangiocarcinoma, (2) typical nipple or rat-tail appearance of the distal common bile duct in pancreatic head carcinoma, (3) single or multiple sharply and smoothly outlined filling defects within bile duct in all cases of stones, (4) complete obstruction with shallow concavity in ampullary carcinoma, (5) diffuse or segmental narrowing of the intrahepatic bile duct and common bile duct in sclerosing cholangitis, (6) multiple tiny polypoid filling defects of gall bladder, common hepatic duct, and common bile duct in clonorchiasis. (7) normal appearance in hepatitis. The overall diagnostic accuracy of PTC in 66 operated cases was 89.4%, and complications following the examination were significantly reduced by using a fine flexible needle (23 gauge). From the present study it is concluded as follows: 1. To evaluate obstructed or stenosed site accurately, aspiration of bile juice must be preceded by a 23 gauge needle connected to either 10 ml or 5 ml syringe. 2. To diagnose carcinoma of the

  5. Effect on hemostasis of an absorbable hemostatic gelatin sponge after transrectal prostate needle biopsy

    Directory of Open Access Journals (Sweden)

    Kohei Kobatake

    2015-04-01

    Full Text Available Objectives To examine the usefulness of an absorbable hemostatic gelatin sponge for hemostasis after transrectal prostate needle biopsy. Subjects and Methods The subjects comprised 278 participants who underwent transrectal prostate needle biopsy. They were randomly allocated to the gelatin sponge insertion group (group A: 148 participants and to the non-insertion group (group B: 130 participants. In group A, the gelatin sponge was inserted into the rectum immediately after biopsy. A biopsy-induced hemorrhage was defined as a case in which a subject complained of bleeding from the rectum, and excretion of blood clots was confirmed. A blood test was performed before and after biopsy, and a questionnaire survey was given after the biopsy. Results Significantly fewer participants in group A required hemostasis after biopsy compared to group B (3 (2.0% vs. 11 (8.5%, P=0.029. The results of the blood tests and the responses from the questionnaire did not differ significantly between the two groups. In multivariate analysis, only “insertion of a gelatin sponge into the rectum” emerged as a significant predictor of hemostasis. Conclusion Insertion of a gelatin sponge into the rectum after transrectal prostate needle biopsy significantly increases hemostasis without increasing patient symptoms, such as pain and a sense of discomfort.

  6. Uncommon primary tumors of the orbit diagnosed by computed tomography-guided core needle biopsy: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Matushita Junior, Joao Paulo Kawaoka; Bitencourt, Almir Galvao Vieira; Amoedo, Mauricio Kauark; Barbosa, Paula Nicole Vieira; Chojniak, Rubens, E-mail: almirgvb@yahoo.com.br [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil). Dept. de Imagem; Neves, Flavia Branco Cerqueira Serra [Hospital do Servidor Publico Estadual, Sao Paulo, SP (Brazil). Div. de Oftalmologia

    2014-11-15

    Computed tomography-guided percutaneous biopsy is a safe and effective alternative method for evaluating selected intra-orbital lesions where the preoperative diagnosis is important for the therapeutic planning. The authors describe two cases of patients with uncommon primary orbital tumors whose diagnosis was obtained by means of computed tomography-guided core needle biopsy, with emphasis on the technical aspects of the procedure. (author)

  7. Placement of percutaneous transhepatic biliary stent using a silicone drain with channels

    Science.gov (United States)

    Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi

    2009-01-01

    This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159

  8. Surgical treatment of Achilles tendon ruptures: the comparison of open and percutaneous methods in a rabbit model.

    Science.gov (United States)

    Yılmaz, Güney; Doral, Mahmut Nedim; Turhan, Egemen; Dönmez, Gürhan; Atay, Ahmet Özgür; Kaya, Defne

    2014-09-01

    This study was intended to investigate the healing properties of open and percutaneous techniques in a rabbit model and compare histological, electron microscopical, and biomechanical findings of the healed tendon between the groups. Twenty-six rabbits were randomly assigned to two groups of thirteen rabbits each. Percutaneous tenotomy of the Achilles tendon (AT) was applied through a stab incision on the right side 1.5 cm above the calcaneal insertion in all animals. Using the same Bunnell suture, the first group was repaired with the open and the second group was repaired with the percutaneous method. ATs were harvested at the end of eight weeks for biomechanical and histological evaluation. When the sections were evaluated for fibrillar density under electron microscopy, it was noted that fibrils were more abundant in the percutaneous repair group. The tendon scores in the percutaneous group were less than the open group indicating closer histological morphology to normal. The difference was not significant (p=0.065). The mean force to rupture the tendon was 143.7± 9.5 N in percutaneous group and 139.2±8.2 N in the open group. The difference was not significant (p=0.33). Percutaneous techniques provide as good clinical results as the open techniques do. The healing tendon shows better findings in histological and electron microscopical level with percutaneous technique.

  9. Rapid prototyping model for percutaneous nephrolithotomy training.

    Science.gov (United States)

    Bruyère, Franck; Leroux, Cecile; Brunereau, Laurent; Lermusiaux, Patrick

    2008-01-01

    Rapid prototyping is a technique used for creating computer images in three dimensions more efficiently than classic techniques. Percutaneous nephrolithotomy (PCNL) is a popular method to remove kidney stones; however, broader use by the urologic community has been hampered by the morbidity associated with needle puncture to gain access to the renal calix (bleeding, pneumothorax, hydrothorax, inadvertent colon injury). A training model to improve technique and understanding of renal anatomy could improve complications related to renal puncture; however, no model currently exists for resident training. We created a training model using the rapid prototyping technique based on abdominal CT images of a patient scheduled to undergo PCNL. This allowed our staff and residents to train on the model before performing the operation. This model allowed anticipation of particular difficulties inherent to the patient's anatomy. After training, the procedure proceeded without complication, and the patient was discharged at postoperative day 1 without problems. We hypothesize that rapid prototyping could be useful for resident education, allowing the creation of numerous models for research and surgical training. In addition, we anticipate that experienced urologists could find this technique helpful in preparation for difficult PCNL operations.

  10. Hemlock woolly adelgid (Homoptera: Adelgidae): stylet bundle insertion and feeding sites

    Science.gov (United States)

    Rebecca F. Young; Kathleen S. Shields; Graeme P. Berlyn

    1995-01-01

    Stylet bundle insertion site, path traveled, and feeding site were examined for the hemlock woolly adelgid, Adelges tsugae Annand, on needles from current and previous years of eastern hemlock, Tsuga canadensis Carriere. The stylet bundle is composed of 4 individual stylets--2 outer mandibular stylets and 2 inner maxillary stylets...

  11. [An Introduction to A Newly-developed "Acupuncture Needle Manipulation Training-evaluation System" Based on Optical Motion Capture Technique].

    Science.gov (United States)

    Zhang, Ao; Yan, Xing-Ke; Liu, An-Guo

    2016-12-25

    In the present paper, the authors introduce a newly-developed "Acupuncture Needle Manipulation Training-evaluation System" based on optical motion capture technique. It is composed of two parts, sensor and software, and overcomes some shortages of mechanical motion capture technique. This device is able to analyze the data of operations of the pressing-hand and needle-insertion hand during acupuncture performance and its software contains personal computer (PC) version, Android version, and Internetwork Operating System (IOS) Apple version. It is competent in recording and analyzing information of any ope-rator's needling manipulations, and is quite helpful for teachers in teaching, training and examining students in clinical practice.

  12. Percutaneous cholecystostomy at the community hospital: value evaluation

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Lee, Mi Suk; Lee, Jin Hee; Ym, Seong Hee; Yoon, Young Gun; Sohn, Myung Hee; Kim, Chong Soo; Han, Young Min; Choi, Ki Chul

    1997-01-01

    To assess the role of percutaneous cholecystostomy as a therapeutic maneuver in patients critically ill with acute cholecystitis in community hospitals. Eighteen patients, 11 with suspected acute calculous cholecystits and seven with acute acalulous cholecystitis underwent emergency percutaneous cholecystostomy. All demonstrated a variety of high risk factors for cholecystectomy:liver cirrhosis(n=3D2), diabetes mellitus(n=3D3), cardiac disease(n=3D3), underlying malignancy(n=3D2), pulmonary dysfunction(n=3D1), septic cholangitis(n=3D5), and old age(n=3D2). All percutaneous cholecystostomies were performed with ultrasound guidance and preferably using the transhepatic route. All procedures but one were successful, and most cholecystostomies were performed within 5-20 minutes. Technical problems were as follows: guide-wire buckling during catheter insertion(n=3D2) and procedure failure(n=3D1). The only major problem was a case of localized bile peritonitis due to procedural failure, but a few minor complications were encountered:catheter dislodgment(n=3D3), and significant abdominal pain during the procedure(2). After successful cholecystostomy, a dramatic improvement in clinical condition was observed in 16 of 17 patients(94%) within 48 hours. Ten of 16 patients who responded to percutaneous cholecystostomy underwent elective cholecystectomy after the improvement of clinical symptoms, and the remaining six patients improved without other gallbladder interventions. Percutaneous cholecystostomy is not only an effective procedure for acute cholecystitis, but also has a definite role in the management of these high-risk patients in community hospitals.=20

  13. Percutaneous cholecystostomy at the community hospital: value evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Lee, Mi Suk; Lee, Jin Hee; Ym, Seong Hee; Yoon, Young Gun [Namwon Medical Center, Namwon (Korea, Republic of); Sohn, Myung Hee; Kim, Chong Soo; Han, Young Min; Choi, Ki Chul [Chonbuk National Univ., Chonju (Korea, Republic of)

    1997-10-01

    To assess the role of percutaneous cholecystostomy as a therapeutic maneuver in patients critically ill with acute cholecystitis in community hospitals. Eighteen patients, 11 with suspected acute calculous cholecystits and seven with acute acalulous cholecystitis underwent emergency percutaneous cholecystostomy. All demonstrated a variety of high risk factors for cholecystectomy:liver cirrhosis(n=3D2), diabetes mellitus(n=3D3), cardiac disease(n=3D3), underlying malignancy(n=3D2), pulmonary dysfunction(n=3D1), septic cholangitis(n=3D5), and old age(n=3D2). All percutaneous cholecystostomies were performed with ultrasound guidance and preferably using the transhepatic route. All procedures but one were successful, and most cholecystostomies were performed within 5-20 minutes. Technical problems were as follows: guide-wire buckling during catheter insertion(n=3D2) and procedure failure(n=3D1). The only major problem was a case of localized bile peritonitis due to procedural failure, but a few minor complications were encountered:catheter dislodgment(n=3D3), and significant abdominal pain during the procedure(2). After successful cholecystostomy, a dramatic improvement in clinical condition was observed in 16 of 17 patients(94%) within 48 hours. Ten of 16 patients who responded to percutaneous cholecystostomy underwent elective cholecystectomy after the improvement of clinical symptoms, and the remaining six patients improved without other gallbladder interventions. Percutaneous cholecystostomy is not only an effective procedure for acute cholecystitis, but also has a definite role in the management of these high-risk patients in community hospitals.=20.

  14. Ultrasound-Guided Percutaneous Electrolysis and Eccentric Exercises for Subacromial Pain Syndrome: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    José L. Arias-Buría

    2015-01-01

    Full Text Available Objective. To compare effects of ultrasound- (US- guided percutaneous electrolysis combined with an eccentric exercise program of the rotator cuff muscles in subacromial pain syndrome. Methods. Thirty-six patients were randomized and assigned into US-guided percutaneous electrolysis (n=17 group or exercise (n=19 group. Patients were asked to perform an eccentric exercise program of the rotator cuff muscles twice every day for 4 weeks. Participants assigned to US-guided percutaneous electrolysis group also received the application of galvanic current through acupuncture needle on each session once a week (total 4 sessions. Shoulder pain (NPRS and disability (DASH were assessed at baseline, after 2 sessions, and 1 week after the last session. Results. The ANOVA revealed significant Group∗Time interactions for shoulder pain and disability (all, P<0.01: individuals receiving US-guided percutaneous electrolysis combined with the eccentric exercises experienced greater improvement than those receiving eccentric exercise alone. Conclusions. US-guided percutaneous electrolysis combined with eccentric exercises resulted in small better outcomes at short term compared to when only eccentric exercises were applied in subacromial pain syndrome. The effect was statistically and clinically significant for shoulder pain but below minimal clinical difference for function. Future studies should investigate the long-term effects and potential placebo effect of this intervention.

  15. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection; Biopsia percutanea de massas pancreaticas guiada por tomografia computadorizada com pneumodisseccao

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens, E-mail: chiangjengtyng@gmail.com [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Imagem; Coimbra, Felipe Jose Fernandez [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Cirurgia Abdominal

    2013-05-15

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  16. Percutaneous Nephrolithotomy in Children

    Directory of Open Access Journals (Sweden)

    Romano T. DeMarco

    2011-01-01

    Full Text Available The surgical management of pediatric stone disease has evolved significantly over the last three decades. Prior to the introduction of shockwave lithotripsy (SWL in the 1980s, open lithotomy was the lone therapy for children with upper tract calculi. Since then, SWL has been the procedure of choice in most pediatric centers for children with large renal calculi. While other therapies such as percutaneous nephrolithotomy (PNL were also being advanced around the same time, PNL was generally seen as a suitable therapy in adults because of the concerns for damage in the developing kidney. However, recent advances in endoscopic instrumentation and renal access techniques have led to an increase in its use in the pediatric population, particularly in those children with large upper tract stones. This paper is a review of the literature focusing on the indications, techniques, results, and complications of PNL in children with renal calculi.

  17. Outcome of Percutaneous Nephrolithotomy

    International Nuclear Information System (INIS)

    Ali, S.; Kumar, N.; Baloch, U.

    2014-01-01

    Objective: To assess the implementation of Percutaneous Nephrolithotomy (PCNL) in renal stone management and evaluate the factors for efficacy and safety of PCNL. Study Design: Case series. Place and Duration of Study: Department of Urology at Jinnah Postgraduate Medical Centre, Karachi, from January 2008 to December 2011. Methodology: Patients aged above 12 years of age, irrespective of gender with normal renal function, mean stone size > 2 cm, lower pole stones > 1 cm, and ESWL failure were selected. After the procedure, on the first postoperative day, a plain abdominal radiograph was obtained to verify stone clearance. A nephrostomy tube was clamped overnight and subsequently removed when no residual stone which needs second sitting was seen. Results: In 175 patients, 62.86% (n=110) were male and the mean age was 35 A +- 9.56 years. One hundred and seventeen (66.85%) patients were primarily stone free and 13.71% (n=24) patients needed a second look procedure, thus, a total of 80.57% (n=141) patients were stone free in the same admission. Complications included failure in 4.0% (n=7) patients, bleeding in 8.57% (n=15) patients, a small residual stone in 15.43% (n=27) patients; and puncture site pain almost in every patient. Transient fever occurred in 55.43% (n=97) patients, urinary leakage in 8.57% (n=15) patients, urinary tract infections in 5.14% (n=9) patients, ureteric colic in 3.43% (n=6) patients, colonic injury in 0.57% (n=1) patient; and nephrectomy was required in 0.57% (n=1) patient due to severe bleeding. One patient (0.57%) expired due to anaesthesia complications. Conclusion: Percutaneous nephrolithotomy (PCNL) has a good success rate. There is minimal blood loss, and few major complications. (author)

  18. Cone-Beam Computed Tomography-Guided Percutaneous Radiologic Gastrostomy

    International Nuclear Information System (INIS)

    Moehlenbruch, Markus; Nelles, Michael; Thomas, Daniel; Willinek, Winfried; Gerstner, Andreas; Schild, Hans H.; Wilhelm, Kai

    2010-01-01

    The purpose of this study was to investigate the feasibility of a flat-detector C-arm-guided radiographic technique (cone-beam computed tomography [CBCT]) for percutaneous radiologic gastrostomy (PRG) insertion. Eighteen patients (13 men and 5 women; mean age 62 years) in whom percutaneous endoscopic gastrostomy (PEG) had failed underwent CBCT-guided PRG insertion. PEG failure or unsuitability was caused by upper gastrointestinal tract obstruction in all cases. Indications for gastrostomy were esophageal and head and neck malignancies, respectively. Before the PRG procedure, initial C-arm CBCT scans were acquired. Three- and 2-dimensional soft-tissue reconstructions of the epigastrium region were generated on a dedicated workstation. Subsequently, gastropexy was performed with T-fasteners after CBCT-guided puncture of the stomach bubble, followed by insertion of an 14F balloon-retained catheter through a peel-away introducer. Puncture of the stomach bubble and PRG insertion was technically successful in all patients without alteration of the epigastric region. There was no malpositioning of the tube or other major periprocedural complications. In 2 patients, minor complications occurred during the first 30 days of follow-up (PRG malfunction: n = 1; slight infection: n = 1). Late complications, which were mainly tube disturbances, were observed in 2 patients. The mean follow-up time was 212 days. CBCT-guided PRG is a safe, well-tolerated, and successful method of gastrostomy insertion in patients in whom endoscopic gastrostomy is not feasible. CBCT provides detailed imaging of the soft tissue and surrounding structures of the epigastric region in one diagnostic tour and thus significantly improves the planning of PRG procedures.

  19. Advances in percutaneous stone surgery

    OpenAIRE

    Hartman, Christopher; Gupta, Nikhil; Leavitt, David; Hoenig, David; Okeke, Zeph; Smith, Arthur

    2015-01-01

    Treatment of large renal stones has changed considerably in recent years. The increasing prevalence of nephrolithiasis has mandated that urologists perform more surgeries for large renal calculi than before, and this has been met with improvements in percutaneous stone surgery. In this review paper, we examine recent developments in percutaneous stone surgery, including advances in diagnosis and preoperative planning, renal access, patient position, tract dilation, nephroscopes, lithotripsy, ...

  20. Advances in percutaneous stone surgery.

    Science.gov (United States)

    Hartman, Christopher; Gupta, Nikhil; Leavitt, David; Hoenig, David; Okeke, Zeph; Smith, Arthur

    2015-01-01

    Treatment of large renal stones has changed considerably in recent years. The increasing prevalence of nephrolithiasis has mandated that urologists perform more surgeries for large renal calculi than before, and this has been met with improvements in percutaneous stone surgery. In this review paper, we examine recent developments in percutaneous stone surgery, including advances in diagnosis and preoperative planning, renal access, patient position, tract dilation, nephroscopes, lithotripsy, exit strategies, and post-operative antibiotic prophylaxis.

  1. Fuel assembly insertion system

    International Nuclear Information System (INIS)

    Barkhurst, D.J.

    1987-01-01

    This patent describes a nuclear reactor facility having fuel bundles: a system for the insertion of a fuel bundle into a position where vertically arranged fuel bundles surround and are adjacent the system comprising, in combination, separate and individual centering devices secured to and disposed on top of each fuel bundle adjacent the position. Each such centering device has a generally box-like cap configuration on the upper end of each fuel bundle and includes: a top wall; first and second side walls, each secured along and upper edge to the top wall; a rear plate attached along opposite vertical edges to the first and second side walls; a front inclined wall joined along an upper edge to the top to the wall and attached along opposite vertical edges first and second side walls; pad means secured to the lower edge of the first and second side walls, the front inclined wall and the rear plate for mounting each centering device on top of an associated fuel bundle; pin means carried by at least two of the pad means engageable with an associated aperature for locating and laterally fixing each centering device on top of its respective fuel bundle. Each front inclined wall of each of the centering devices is orientated on top of its respective fuel bundle to slope upwardly and away from the position where upon downward insertion of a fuel bundle any contact between the lower end of the fuel bundle inserted with a front inclined wall of a centering device will laterally deflect the fuel bundle. Each centering device further includes a central socket means secured to the top wall, and an elongated handling pole pivotally attached to the socket

  2. Arched needle technique for inferior alveolar mandibular nerve block.

    Science.gov (United States)

    Chakranarayan, Ashish; Mukherjee, B

    2013-03-01

    One of the most commonly used local anesthetic techniques in dentistry is the Fischer's technique for the inferior alveolar nerve block. Incidentally this technique also suffers the maximum failure rate of approximately 35-45%. We studied a method of inferior alveolar nerve block by injecting a local anesthetic solution into the pterygomandibular space by arching and changing the approach angle of the conventional technique and estimated its efficacy. The needle after the initial insertion is arched and inserted in a manner that it approaches the medial surface of the ramus at an angle almost perpendicular to it. The technique was applied to 100 patients for mandibular molar extraction and the anesthetic effects were assessed. A success rate of 98% was obtained.

  3. Percutaneous osteoid osteoma treatment with combination of radiofrequency and alcohol ablation

    Energy Technology Data Exchange (ETDEWEB)

    Akhlaghpoor, S. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of)]. E-mail: akhlaghpoor@nmri-ir.com; Tomasian, A. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of); Arjmand Shabestari, A. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of); Ebrahimi, M. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of); Alinaghizadeh, M.R. [Noor Medical Imaging Center, Tehran (Iran, Islamic Republic of)

    2007-03-15

    Aim: To assess the efficacy of percutaneous osteoid osteoma treatment using a combination of radiofrequency ablation (RFA) and alcohol ablation with regard to technical and long-term clinical success. Materials and methods: From December 2001 to November 2004, RFA and subsequent alcohol ablation was performed on 54 patients with osteoid osteoma, diagnosed clinically using radiography, computed tomography (CT) and symptoms. Under general anaesthesia, treatment was performed via percutaneous access under thin section (2 mm) spiral CT guidance in all cases with an 11 G radiofrequency-compatible coaxial needle and 2 mm coaxial drill system and 1.0 cm active tip 17 G non-cooled radiofrequency needle. RFA was performed at 90 {sup o}C for a period of 6 min. After needle removal, 0.5-1.0 ml absolute alcohol (99.8% concentration) was injected directly into the nidus using a 20 G needle. Patients were discharged within 24 h and followed up clinically (at 1 week, 1 month and every 3 months thereafter). Results: The technical success rate was 100%. Complications occurred in two patients consisting of local mild cellulitis in entry site and peripheral small zone paresthesia on the anterior part of leg. The follow-up period range was 13-48 months (mean {+-} SD, 28.2 {+-} 7.4 months). Prompt pain relief and return to normal activities were observed in 52 of 54 patients. Recurrent pain occurred in two patients after a 1 and 3 months period of being pain free, respectively; a second RFA and alcohol ablation was performed achieving successful results. Primary and secondary clinical success rates were 96.3% (52/54 patients) and 100% (2/2 patients), respectively. Conclusion: Percutaneous osteoid osteoma treatment with combination of radiofrequency and alcohol ablation is safe, effective and minimally invasive with high primary and secondary success rates. Persistent or recurrent lesions can be effectively re-treated.

  4. Percutaneous osteoid osteoma treatment with combination of radiofrequency and alcohol ablation

    International Nuclear Information System (INIS)

    Akhlaghpoor, S.; Tomasian, A.; Arjmand Shabestari, A.; Ebrahimi, M.; Alinaghizadeh, M.R.

    2007-01-01

    Aim: To assess the efficacy of percutaneous osteoid osteoma treatment using a combination of radiofrequency ablation (RFA) and alcohol ablation with regard to technical and long-term clinical success. Materials and methods: From December 2001 to November 2004, RFA and subsequent alcohol ablation was performed on 54 patients with osteoid osteoma, diagnosed clinically using radiography, computed tomography (CT) and symptoms. Under general anaesthesia, treatment was performed via percutaneous access under thin section (2 mm) spiral CT guidance in all cases with an 11 G radiofrequency-compatible coaxial needle and 2 mm coaxial drill system and 1.0 cm active tip 17 G non-cooled radiofrequency needle. RFA was performed at 90 o C for a period of 6 min. After needle removal, 0.5-1.0 ml absolute alcohol (99.8% concentration) was injected directly into the nidus using a 20 G needle. Patients were discharged within 24 h and followed up clinically (at 1 week, 1 month and every 3 months thereafter). Results: The technical success rate was 100%. Complications occurred in two patients consisting of local mild cellulitis in entry site and peripheral small zone paresthesia on the anterior part of leg. The follow-up period range was 13-48 months (mean ± SD, 28.2 ± 7.4 months). Prompt pain relief and return to normal activities were observed in 52 of 54 patients. Recurrent pain occurred in two patients after a 1 and 3 months period of being pain free, respectively; a second RFA and alcohol ablation was performed achieving successful results. Primary and secondary clinical success rates were 96.3% (52/54 patients) and 100% (2/2 patients), respectively. Conclusion: Percutaneous osteoid osteoma treatment with combination of radiofrequency and alcohol ablation is safe, effective and minimally invasive with high primary and secondary success rates. Persistent or recurrent lesions can be effectively re-treated

  5. Data Insertion in Bitcoin's Blockchain

    Directory of Open Access Journals (Sweden)

    Andrew Sward

    2018-04-01

    Full Text Available This paper provides the first comprehensive survey of methods for inserting arbitrary data into Bitcoin’s blockchain. Historical methods of data insertion are described, along with lesser-known techniques that are optimized for efficiency. Insertion methods are compared on the basis of efficiency, cost, convenience of data reconstruction, permanence, and potentially negative impact on the Bitcoin ecosystem.

  6. Changing the needle for lumbar punctures

    DEFF Research Database (Denmark)

    Engedal, Thorbjørn Søndergaard; Ording, H.; Vilholm, O. J.

    2015-01-01

    Objective: Post-dural puncture headache (PDPH) is a common complication of diagnostic lumbar punctures. Both a non-cutting needle design and the use of smaller size needles have been shown to greatly reduce the risk of PDPH. Nevertheless, larger cutting needles are still widely used. This study d...

  7. Relations between Scots pine needle element concentrations and decreased needle longevity along pollution gradients

    International Nuclear Information System (INIS)

    Lamppu, Jukka; Huttunen, Satu

    2003-01-01

    Deceased needle longevity was related to increased heavy metal concentrations. - Scots pine (Pinus sylvestris L.) shoots were sampled along transects near one urban pollution source and two smelters. Needle Mg, P and K concentrations decreased from the second to the fourth age class linearly with needle survival along the urban pollution gradient. Still, over 80% of the average concentration of these nutrients remained in the fourth needle age class. Decreased needle longevity was closely related to the increased heavy metal concentrations near the smelters. Near the urban pollution source, it was related to the increased annual needle mass and the increased needle nutrient concentrations. Decreased Mn accumulation along with needle age was detected near all pollution sources. Leaching of Mn from needles and especially from soil as a cause of decreased needle concentrations is discussed

  8. Tracheostomy: from insertion to decannulation

    Science.gov (United States)

    Engels, Paul T.; Bagshaw, Sean M.; Meier, Michael; Brindley, Peter G.

    2009-01-01

    Tracheostomy is a common surgical procedure, and is increasingly performed in the intensive care unit (ICU) as opposed to the operating room. Procedural knowledge is essential and is therefore outlined in this review. We also review several high-quality studies comparing percutaneous dilational tracheostomy and open surgical tracheostomy. The percutaneous method has a comparable, if not superior, safety profile and lower cost compared with the open surgical approach; therefore the percutaneous method is increasingly chosen. Studies comparing early versus late tracheostomy suggest morbidity benefits that include less nosocomial pneumonia, shorter mechanical ventilation and shorter stay in the ICU. However, we discuss the questions that remain regarding the optimal timing of tracheostomy. We outline the potential acute and chronic complications of tracheostomy and their management, and we review the different tracheostomy tubes, their indications and when to remove them. PMID:19865580

  9. Smartphone-Guided Needle Angle Selection During CT-Guided Procedures.

    Science.gov (United States)

    Xu, Sheng; Krishnasamy, Venkatesh; Levy, Elliot; Li, Ming; Tse, Zion Tsz Ho; Wood, Bradford John

    2018-01-01

    In CT-guided intervention, translation from a planned needle insertion angle to the actual insertion angle is estimated only with the physician's visuospatial abilities. An iPhone app was developed to reduce reliance on operator ability to estimate and reproduce angles. The iPhone app overlays the planned angle on the smartphone's camera display in real-time based on the smartphone's orientation. The needle's angle is selected by visually comparing the actual needle with the guideline in the display. If the smartphone's screen is perpendicular to the planned path, the smartphone shows the Bull's-Eye View mode, in which the angle is selected after the needle's hub overlaps the tip in the camera. In phantom studies, we evaluated the accuracies of the hardware, the Guideline mode, and the Bull's-Eye View mode and showed the app's clinical efficacy. A proof-of-concept clinical case was also performed. The hardware accuracy was 0.37° ± 0.27° (mean ± SD). The mean error and navigation time were 1.0° ± 0.9° and 8.7 ± 2.3 seconds for a senior radiologist with 25 years' experience and 1.5° ± 1.3° and 8.0 ± 1.6 seconds for a junior radiologist with 4 years' experience. The accuracy of the Bull's-Eye View mode was 2.9° ± 1.1°. Combined CT and smart-phone guidance was significantly more accurate than CT-only guidance for the first needle pass (p = 0.046), which led to a smaller final targeting error (mean distance from needle tip to target, 2.5 vs 7.9 mm). Mobile devices can be useful for guiding needle-based interventions. The hardware is low cost and widely available. The method is accurate, effective, and easy to implement.

  10. Pneumatically Operated MRI-Compatible Needle Placement Robot for Prostate Interventions.

    Science.gov (United States)

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Mewes, Philip W; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-13

    Magnetic Resonance Imaging (MRI) has potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. The strong magnetic field prevents the use of conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intra-prostatic needle placement inside closed high-field MRI scanners. The robot performs needle insertion under real-time 3T MR image guidance; workspace requirements, MR compatibility, and workflow have been evaluated on phantoms. The paper explains the robot mechanism and controller design and presents results of preliminary evaluation of the system.

  11. Susuks (charm needles) in the craniofacial region

    International Nuclear Information System (INIS)

    Nambiar, P.; Ibrahim, N.; Tandjung, Y.R.M.; Shanmuhasuntharam, P.

    2008-01-01

    We conducted a study to determine the numbers of susuks (charm needles) and their distribution in the craniofacial region of susuk wearers, and the sex, racial affiliation, and age of the wearers. In addition, we sought to determine whether the presence of susuks posed any potential hazard to patients undergoing magnetic resonance imaging (MRI). We studied various radiographs of 33 susuk wearers (age range, 33-69 years) and investigated the most common sites of insertion in the craniofacial region. A susuk was also suspended inside a 1.5-T MRI machine to determined whether it was attracted by the machine's magnet. The largest number of susuks that we observed in the craniofacial region was 39 pins, and susuks were particularly numerous in Malay Muslim women. Other sites with susuks were the maxillofacial region (except the temporomandibular region) and the forehead. The susuks showed no ferromagnetic characteristics. As susuks are made from gold, they are generally biocompatible with human tissue and do not cause problems to their wearers. Gold and the other minor metal constituents found in susuks have no ferromagnetic characteristics and therefore pose no hazard to patients undergoing MRI. (author)

  12. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Borot de Battisti, Maxence, E-mail: M.E.P.Borot@umcutrecht.nl; Maenhout, Metha; Lagendijk, Jan J. W.; Vulpen, Marco van; Moerland, Marinus A. [Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX (Netherlands); Denis de Senneville, Baudouin [Imaging Division, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3584 CX, The Netherlands and IMB, UMR 5251 CNRS/University of Bordeaux, Talence 33400 (France); Hautvast, Gilion; Binnekamp, Dirk [Philips Group Innovation Biomedical Systems, Eindhoven 5656 AE (Netherlands)

    2016-10-15

    Purpose: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image interpretation can be hampered by signal voids arising from blood vessels or calcifications limiting the precision of the needle guidance and reconstruction. In this paper, a new needle tracking prototype is investigated using fiber Bragg gratings (FBG)-based sensing: this prototype involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. This stylet can be inserted into brachytherapy needles and allows a fast measurement of the needle deflection. This study aims to assess the potential of FBG-based sensing for real-time needle (including catheter or tube) tracking during MR-guided intervention. Methods: First, the MR compatibility of FBG-based sensing and its accuracy was evaluated. Different known needle deflections were measured using FBG-based sensing during simultaneous MR-imaging. Then, a needle tracking procedure using FBG-based sensing was proposed. This procedure involved a MR-based calibration of the FBG-based system performed prior to the interventional procedure. The needle tracking system was assessed in an experiment with a moving phantom during MR imaging. The FBG-based system was quantified by comparing the gold-standard shapes, the shape manually segmented on MRI and the FBG-based measurements. Results: The evaluation of the MR compatibility of FBG-based sensing and its accuracy shows that the needle deflection could be measured with an accuracy of 0.27 mm on average. Besides, the FBG-based measurements were comparable to the uncertainty of MR-based measurements estimated at half the voxel size in the MR image. Finally, the mean(standard deviation) Euclidean distance between MR- and FBG-based needle position

  13. Efficacy of Tuohy Needle in Oocytes Collection from Excised Mare Ovaries

    Directory of Open Access Journals (Sweden)

    F. Cremonesi

    2010-01-01

    Full Text Available Two methods have been described to recover oocytes from equine follicles in excised ovaries: aspiration and scraping. Aim of this work was to develop an effective method for collecting equine oocytes using Tuohy needle and comparing this technique to aspiration and scraping, with or without tunica albuginea removal. This hollow hypodermic needle, usually employed for inserting epidural catheters, is designed with a slightly curved tip, shaped similar to a small curette. In unpeeled ovaries, the recovery rates of Tuohy needle group was higher (<.05 than in the 16 g needle aspiration and in the scraped ovaries (57% versus 36% and 47% while the rate of cumulus-intact oocytes was higher than aspiration (46.9% versus 39.36% but lower than scraping (46.97% (<.001. In unpeeled ovaries there was significant difference in maturation rate of oocytes recovered by Tuohy needle in respect to peeled ovaries (58.54% versus 50.17%, resp.. Combination of aspiration and scraping by Tuohy needle allows a faster and reliable collection of oocytes suitable for horse IVM.

  14. Initial validation of a virtual blood draw exposure paradigm for fear of blood and needles.

    Science.gov (United States)

    Trost, Z; Jones, A; Guck, A; Vervoort, T; Kowalsky, J M; France, C R

    2017-10-01

    Fear of blood, injections, and needles commonly prevents or delays individuals' receipt of health care, such as vaccines or blood draws. Innovative methods are needed to overcome these fears and reduce anxiety related to activities of this nature. The present study describes initial testing of an arm illusion paradigm that may prove useful during early phases of graded exposure for people with blood and needle fear. Seventy-four undergraduate students aged 18-29 years were tested. In line with study aims, results indicated that the virtual blood draw paradigm promoted strong perceptions of arm ownership and elicited significant changes in physiological indices (blood pressure, heart rate, electrodermal activity, respiratory rate) in response to key procedure elements (e.g., needle insertion). Further, bivariate correlations indicated that individual differences in self-reported blood and needle fear collected prior to the illusion paradigm were significantly associated with presyncopal symptoms reported following the procedure. In regression analyses, self-reported measures of blood and needle fear explained unique variance in presyncopal symptoms even after controlling for general state anxiety. These findings provide initial support for the virtual blood draw paradigm as a promising tool to help provide graded exposure to medical procedures involving needles and blood draw. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Reduction of Zygomatic Arch Isolated Fracture Using Ultra Sound and Needle Marking.

    Science.gov (United States)

    Kim, Jun Sik; Park, Young Ji; Lee, Yoon Jung; Kim, Nam Gyun; Lee, Kyung Suk

    2016-12-01

    Zygomatic arch is a bony arch constituting the lateral midface, which consists of 25% of all midface fractures. There are a number of ways to evaluate the extent of zygomatic arch fracture. Some authors have reported successful treatment outcomes using ultrasound (U/S). To add to the previous methods, we have considered ways to accurately display the location of the fracture line while using U/S with 23 gauge needle marking. We introduce our method, which provided satisfactory results for reduction using a portable U/S, and it can evaluate the fracture line simultaneously when reduction of an isolated zygomatic arch fracture is necessary, and needle marking, which can easily point out the fracture line on U/S. We studied 21 patients with an isolated zygomatic arch fracture who underwent closed reduction using U/S and needle marking between 2013 and 2015. We achieved satisfactory results in all our cases with respect to reduction by using the Dingman elevator after performing a temporal approach incision, while confirming relative positioning between needle marking and zygomatic fracture at the same time, after insertion of a 23 gauge needle in the skin above the zygomatic arch fracture line parallel to it. We treated 21 patients with an isolated zygomatic arch fracture using U/S and the needle marking method, which provided satisfactory results because the extent of reduction of the fracture could be evaluated in real-time during the operation and exposure to radiation was reduced.

  16. Duodenal perforation during percutaneous nephrolithotomy (PCNL ...

    African Journals Online (AJOL)

    A. Bansal

    2016-06-03

    Jun 3, 2016 ... Calculus;. Duodenum;. Injury;. Paediatric;. Percutaneous nephrolithotomy. Abstract. Introduction: Colonic perforations are known complications of percutaneous nephrolithotomy (PCNL). However, to the best of our knowledge, small bowel perforation has rarely been reported.. Observation: We report the ...

  17. Central venous obstruction in hemodialysis patients: the usefulness of percutaneous treatment

    International Nuclear Information System (INIS)

    Kim, Cheol Young; Goo, Dong Erk; Kim, Dae Ho; Hong, Hyun Suk; Lee, Hae Kyoung; Choi, Duk Lin; Yang, Sung Boo; Moon, Chul

    2002-01-01

    To analyse the effectiveness of percutaneous treatment of central venous obstruction in patients undergoing hemodialysis. In 100 patients, 107 central venous strictures (56 subclavian (occlusion:21, stenosis:35) and 51 innominate (occlusion:23,stenosis:28)) were assessed, and 170 percutaneous angioplasty procedures were performed. Balloon dilation of the venous lumen was the preferred mode, but if dilation was incomplete we inserted a stent at the site of the stricture. Technical success, procedural complications and the long-term patency rate were evaluated, and the patency difference according to location and degree of stricture, the existence of DM, and any history of central catheter insertion was also determined. We inserted 52 stents in 170 procedures, in 157 (92.4%) of which initial technical success was achieved. Stent migration occurred in two cases and balloon rupture in three. The 6- and 12-month primary patency rates were 46.2% and 24.1%, respectively, and the mean patency rate was 8.5 months. The 1-, 2-and 3-year accumulative patency rates were 59.8%, 47.5% and 35.7%, respectively, and the mean patency rate was 23.5 months. Other than in the history of central catheter insertion, there were no statistically significant differences in patency rates (p=0.0128). In hemodialysis patients with a central venous stricture, percutaneous angioplasty is a safe and useful procedure, but to maintain long-term central venous patency, repeated interventions are required

  18. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Welch, B. T.; Eiken, P. W.; Atwell, T. D.; Peikert, T.; Yi, E. S.; Nichols, F.; Schmit, G. D.

    2017-01-01

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  19. CT-guided percutaneous radiofrequency ablation of hepatic malignancies located in unusual regions under general anesthesia

    International Nuclear Information System (INIS)

    Pan Jie; Chen Shaohui; Lu Xin; Mao Yilei; Sang Xinting; Chen Fang; Li Yumei; Huang Yuguang; Jin Zhengyu

    2010-01-01

    Objective: To discuss the feasibility of CT-guided percutaneous radiofrequency ablation (RFA) of liver malignancies located in unusual regions under general anesthesia, and to assess its clinical value. Methods: Eighteen patients with a total of 26 malignant hepatic lesions were enrolled in this study. The lesions were located at diaphragmatic surface, hepatic hilum, hepatic subcapsular site,side of inferior vena cava, side of gallbladder or near by colon. Transcatheter arterial chemoembolization was performed in all patients, which was followed by CT-guided percutaneous RFA under general anesthesia. The time used for puncturing and the time used for putting the needles to the scheduled sites were recorded. A follow-up for 115 months was conducted. The complications and the therapeutic results were observed. Results: For all patients,the procedure of puncture and needle placement was completed in 1-3 minutes. A total of 35 RFA procedures were conducted for 26 lesions. No severe complications occurred. Complete necrosis was observed in 20 tumors and partial necrosis in 6 tumors. Conclusion: The result of this study indicates that CT-guided percutaneous RFA under general anesthesia is a feasible technique for the treatment of liver malignancies located at unusual regions. This technique is very helpful for reducing the manipulating difficulty and lowing the complication risk of RFA procedures. (authors)

  20. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    International Nuclear Information System (INIS)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens

    2014-01-01

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  1. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D. [Mayo Clinic, Department of Radiology (United States); Peikert, T. [Mayo Clinic, Department of Pulmonary and Critical Care Medicine (United States); Yi, E. S. [Mayo Clinic, Department of Pathology (United States); Nichols, F. [Mayo Clinic, Department of Thoracic Surgery (United States); Schmit, G. D. [Mayo Clinic, Department of Radiology (United States)

    2017-06-15

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  2. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    Energy Technology Data Exchange (ETDEWEB)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens, E-mail: macellomaciel@me.com [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil)

    2014-09-15

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  3. Percutaneous vertebroplasty via anterolateral approach for the treatment of C4 to C7 vertebral tumor

    International Nuclear Information System (INIS)

    Wu Chungen; Cheng Yongde; Gu Yifeng; Zhang Ji; Wang Tao; Li Minghua; Apitzsch, D.E.

    2009-01-01

    Objective To investigate the feasibility and clinical efficacy of percutaneous vertebroplasty via anterolateral approach in treating the middle and lower cervical (C4-C7) vertebral tumor. Methods: During the past four years, percutaneous vertebroplasty via anterolateral approach was performed in 16 patients with middle or lower cervical tumor, including metastases (n=12), myeloma (n=3) and eosinophilic granuloma (n=1). Under fluoroscopic guidance, needle puncture was operated via the anterolateral approach, bone cement was injected into the target cervical body when the needle was in place. A follow-up of three months was made. Results: Twenty-one cervical bodies in the range of C4 to C7 were successfully punctured and injected with bone cement. Marked pain relief was obtained in all 16 patients. The average score of visual analogue scale (VAS) was dramatically decreased from 7 before the procedure to 1.7 after the procedure. The cervical motor function returned to good condition. Conclusion: Percutaneous vertebroplasty via anterolateral approach is a safe, effective and minimally-invasive technique in treating the middle and lower cervical (C4-C7) vertebral tumor. (authors)

  4. Percutaneous Biopsy of Retrobulbar Masses: Anatomical Considerations and MRI Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Edalat, Faramarz, E-mail: faramarz.edalat@gmail.com; Cazzato, Roberto Luigi; Garnon, Julien; Tsoumakidou, Georgia [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France); Avérous, Gerlinde [CHU Strasbourg Hautepierre, Department of Pathology (France); Caudrelier, Jean; Koch, Guillaume; Gangi, Afshin [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France)

    2017-04-15

    PurposeObtaining adequate tissue from retrobulbar masses remains a challenge. To this end, a new method of retrobulbar mass biopsy using MRI guidance is presented.Materials and MethodsTwo patients (7- and 71-year-old male) with indeterminate retrobulbar masses underwent bioptic and cytological samplings using MR-compatible 18G and 20–22G needles, and multi-planar MR fluoroscopy. An inferior approach was taken to avoid injury to the optic nerve and ophthalmic arteries.ResultsThe two biopsies were completed without complication. The core biopsy resulted in a final diagnosis, whereas the cytological sampling was non-diagnostic.ConclusionPercutaneous MR-guided retrobulbar mass biopsy proved to be feasible and safe in the two cases described in this report.

  5. A comparison of buffered lidocaine versus ELA-Max before peripheral intravenous catheter insertions in children.

    Science.gov (United States)

    Luhmann, Janet; Hurt, Sarah; Shootman, Mario; Kennedy, Robert

    2004-03-01

    Peripheral intravenous catheter (PIV) insertion is a common, painful experience for many children in the pediatric emergency department. Although local anesthetics such as injected buffered lidocaine have been shown to be effective at reducing pain and anxiety associated with PIV insertion, they are not routinely used. ELA-Max, a topical local anesthetic, has the advantage of needle-free administration but has not been compared with buffered lidocaine for PIV insertion. To compare the reduction of pain and anxiety during PIV insertion provided by subcutaneous buffered 1% lidocaine or topical ELA-Max in children. A randomized trial in children 4 to 17 years old undergoing PIV insertion with 22-gauge catheters was conducted. Children received either buffered lidocaine or ELA-Max. Buffered lidocaine was administered by using 30-gauge needles to inject 0.1 to 0.2 mL subcutaneously just before PIV insertion. ELA-Max was applied to the skin and occluded with Tegaderm 30 minutes before PIV insertion. Self-reported Visual Analog Scale (VAS) questionnaires (rating on a scale of 1-10; 1 = no pain, anxiety) were completed by patients and their parents before PIV insertion to assess baseline perceptions about pain and anxiety associated with PIV insertion and immediately after PIV insertion to assess pain and anxiety associated with the experience. After PIV insertion, the nurse who inserted the PIV also completed a VAS questionnaire assessing technical difficulty and satisfaction with the local anesthesia. A blinded observer also completed a VAS questionnaire to assess pain and anxiety associated with the PIV insertion. Data were analyzed by using chi2 and t tests. Sixty-nine subjects were enrolled, and questionnaires were competed by all (mean age: 12.1 +/- 4.5 years; 61% female). There were no differences for buffered lidocaine and ELA-Max groups in age, gender, race, prior IV experience, or baseline pain and anxiety. There were no significant differences between buffered

  6. The optical "Veress-needle"--initial puncture with a minioptic.

    Science.gov (United States)

    Schaller, G; Kuenkel, M; Manegold, B C

    1995-02-01

    Laparoscopic access is a necessary part of minimally invasive surgery. The double blind puncture with Veress-needle and trocar can cause lethal complications such as bowel injury, bleeding and gas-embolisation. Some authors have reported alternative techniques for laparoscopic abdominal access. Because no blind procedure can absolutely prevent injury, permanent visual control of perforated tissue layers as in open surgery should be achieved to prevent possible injury at an early stage. Previously described procedures could not fulfil all requirements to comply with this ideal, i.e. permanent visual control of abdominal wall penetration prior to establishment of pneumoperitoneum and trocar insertion without further possible damage. We designed a 2 mm fibreglass optic 250 mm in length that is inserted into a suitable cannula. Special construction allows rinsing through the cannula to clear the vision and to open spaces in the puncture track by water dissection. After incision of the skin, all layers of the abdominal wall can be visualised, including blood vessels and internal surfaces. Once the abdominal cavity is reached, the needle tip is retracted and a two-step dilation allows the trocar to be introduced via the puncture track. Only then does insufflation begin. The fibreglass optic-equipped safety needle was used for visually controlled access in 184 laparoscopic surgical procedures. After a period of training, all layers of the abdominal wall could be recognised exactly. In two patients with dense adhesions, perforation of the small bowel was diagnosed immediately by endoscopic viewing. The small injury needed no treatment, and the intended procedure was completed laparoscopically.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Percutaneous gastrostomy -a report of twenty-seven cases-

    International Nuclear Information System (INIS)

    Kim, Tae Ho; Lee, Ho Suk; Kim, Yong Joo; Kim, Tae Hun; Suh, Kyung Jin; Kang, Duk Sik

    1991-01-01

    Nutritional support by gastrostomy feeding is an important treatment adjunct when major swallowing difficulty or debilitating diseases is present. This technique for percutaneous placement of a gastric feeding tube now provides many patients with a simple, safe, and well-tolerated alternative to surgical feeding gastrostomy. We experienced 27 cases of percutaneous gastrostomy from January 1989 to February 1991 at Kyungpook National University Hospital. The underlying diseases of the patients were esophageal cancer (11), pyriform sinus cancer (4), laryngeal cancer (3), tongue cancer (2), lye stricture (1), lung cancer (1), chordoma (1), lethal midline granuloma (1), malignant lymphoma (1), maxillary cancer (1), and tonsil cancer (1). Selding method was used in all cases. In five patients it was difficult to insert the nasogastric tube for air insufflation, and one patient had subtotal gastrectomy with gastrojejunostomy, but gastrostomy was performed in all cases. The general condition improved in all patients. We experienced one case of mild peritonitis, but no other significant complications were observed. Gastrostomy tubes were patient in all patients during their survival period, except two patients who experienced obstruction 2 and 6 months after the procedure. Percutaneous gastrostomy can be used safely and effectively in such patients who have pharyngoesophageal or CNS lesions precluding oral intake

  8. Percutaneous drainage of abscess in the treatment of emphysematous pyelonephritis

    International Nuclear Information System (INIS)

    Jung, Jin Yong; Jeong, Yong Yeon; Kim, Jae Kyu; Park, Seung Jei; Park, Jin Gyoon; Kang, Heoung Keun; Roh, Byung Suk

    1997-01-01

    To assess the usefulness of percutaneous drainage of abscess in the treatment of emphysematous pyelonephritis. Ten cases of nine patients with emphysematous pyelonephritis were percutaneously drained. All were suffering from diabetes mellitus. The procedure was performed under fluoroscopic guidance in nine cases and US guidance in one case in which bilateral multiloculated abscesses were present in the perirenal space. The results were classified as cure, partial success, recurrence, or failure. The mean drainage period and complication were analyzed. Eight cases were cured, and there was one case success. In one case, who had diffuse renal parenchymal destruction without perirenal fluid collection, the treatment failed. The longest drainage period was 45 days, in a case of re-insertion due to incidental catheter removal; the mean was 23 days. Bacteremia in one case was cured with antibiotic therapy which lasted two days. In diabetic patients, percutaneous drainage of obscess is thought to be a safe and effective method for the treatment of emphysematous pyelonephritis, and is one that does not involve diffuse destruction of renal parenchyma

  9. Percutaneous Endoscopic Gastrostomy in the Enteral Feeding of the Elderly

    Directory of Open Access Journals (Sweden)

    Huan-Lin Chen

    2011-09-01

    Full Text Available Today we are faced with an aging society that may develop malnutrition because of dysphagia related to dementia, stroke, and malignancy seen often in the elderly. The preferred form of nutritional supplementation for this group is enteral nutrition, and the most appropriate long-term method is by use of a gastrostomy. Percutaneous endoscopic gastrostomy (PEG was first introduced in 1980 as an alternative to the traditional operative procedure and rapidly became the preferred procedure. In geriatric patients, the principal indications are neurological dysphagia and malnutrition, related to an underlying disease or anorexia-cachexia in very elderly. PEG is contraindicated in the presence of respiratory distress, previous gastric resection, total esophageal obstruction, coagulation disorders and sepsis in the elderly. Common complications include wound infection, leakage, hemorrhage, and fistula in the general population, but aspiration pneumonia is the major case of death in this group. Risks and complications of PEG must be discussed with patients and their families; and the decision for percutaneous endoscopic gastrostomy insertion should only be made after careful consideration and discussion between managing physicians, allied health professionals, and the patient and/or family. Four ethical principles may help make feeding decisions: beneficence, non-maleficence, autonomy and justice. Attentive long-term care after tube replacement is mandatory. Acceptance of percutaneous endoscopic gastrostomy placement by patients and their families tends to increase once favorable outcomes are offered.

  10. Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach

    Energy Technology Data Exchange (ETDEWEB)

    Petrocelli, Francesco, E-mail: francesco.petrocelli@hsanmartino.it; Salsano, Giancarlo, E-mail: giancarlo.salsano@yahoo.it; Bovio, Giulio, E-mail: giulio.bovio@hsanmartino.it; Camerano, Francesco, E-mail: francesco.camerano@gmail.com; Utili, Alice, E-mail: aliceutili@gmail.com; Ferro, Carlo, E-mail: carlo.ferro@hsanmartino.it [IRCCS San Martino University Hospital, Department of Radiology and Interventional Radiology (Italy)

    2016-07-15

    IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriform sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.

  11. MR guided percutaneous laser lumbar disk hernia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko [Jikei Univ., Chiba (Japan). Kashiwa Hospital; Abe, Toshiaki

    1998-03-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  12. MR guided percutaneous laser lumbar disk hernia ablation

    International Nuclear Information System (INIS)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko; Abe, Toshiaki.

    1998-01-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  13. Effectiveness of Sedoanalgesia in Percutaneous Liver Biopsy Premedication

    Science.gov (United States)

    Sezgin, Orhan; Ates, Fehmi; Altintas, Engin; Saritas, Bunyamin

    2017-01-01

    Aim: Percutaneous needle liver biopsy (PLB) is frequently associated with pain and anxiety. This may discourage the patients for biopsy, and rebiopsies, if needed. We planned a study to investigate the efficacy of additional analgesia or sedation for PLB. Materials and methods: The study has been designed as a single-center, prospective study. The PLB was planned for 18- to 65-year-old consecutive patients who were included in the study. The patients were divided into three premedication groups as control, Meperidine, and Midazolam. Hospital Anxiety and Depression Scale (HADS) was used to measure each subject’s anxiety level. Fifteen minutes before the biopsy, 1 mL 0.9% NaCl subcutaneously (sc), 1 mg/kg (max 100 mg) Meperidine sc, or 0.1 mg/kg (max 5 mg) Midazolam intravenously was administered to patients respectively. Then PLB was done with 16 G Menghini needle. The day after, the patients were asked about feelings regarding biopsy. Results: Groups were similar by gender and age. The HADS scores prior to PLB and on visual analog scale (VAS, 1-10 points) score during PLB were similar. In the three groups, 7, 12, and 7 patients, respectively, experienced no pain. Other patients explained pain as mild or moderate or severe. The number of patients who agreed for possible rebiopsy was higher in Meperidine and Midazolam groups than in the control group. Conclusion: Premedication with Meperidine or Midazolam in PLB would improve patients’ tolerance, comfort, and attitude against a possible repeat PLB. How to cite this article: Sezgin O, Yaras S, Ates F, Altintas E, Saritas B. Effectiveness of Sedoanalgesia in Percutaneous Liver Biopsy Premedication. Euroasian J Hepato-Gastroenterol 2017;7(2):146-149. PMID:29201797

  14. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  15. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  16. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  17. Tattoo machines, needles and utilities.

    Science.gov (United States)

    Rosenkilde, Frank

    2015-01-01

    Starting out as a professional tattooist back in 1977 in Copenhagen, Denmark, Frank Rosenkilde has personally experienced the remarkable development of tattoo machines, needles and utilities: all the way from home-made equipment to industrial products of substantially improved quality. Machines can be constructed like the traditional dual-coil and single-coil machines or can be e-coil, rotary and hybrid machines, with the more convenient and precise rotary machines being the recent trend. This development has resulted in disposable needles and utilities. Newer machines are more easily kept clean and protected with foil to prevent crosscontaminations and infections. The machines and the tattooists' knowledge and awareness about prevention of infection have developed hand-in-hand. For decades, Frank Rosenkilde has been collecting tattoo machines. Part of his collection is presented here, supplemented by his personal notes. © 2015 S. Karger AG, Basel.

  18. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  19. Percutaneous cecostomy: Laboratory and clinical experience with a new radiologic technique

    International Nuclear Information System (INIS)

    Van Sonnenberg, E.; Casola, G.; Wittich, G.R.; Stavas, J.; Quinn, S.F.; Gibbs, J.; Macaulay, S.; Schecter, M.S.; Edwards, K.C.

    1987-01-01

    Percutaneous cecostomy or colostomy is a new interventional radiology procedure used for colonic decompression due to mechanical obstruction or pseudoobstruction. This paper describes our laboratory and initial clinical work with percutaneous colostomy. In our initial nine patient, it has served as a temporizing (five patients), definitive (three patients), or inadvertent maneuver (one patient). Methods of guidance were CT (three patients) and fluoroscopy (six patients). Catheters were placed both transperitoneally and retroperitoneally; laboratory work focused on these paths of introduction as well as catheter insertion and catheter type. The authors used catheters with retention devices preferentially, and these permit adherence of the colon to the abdominal wall. Both Seldinger and trocar techniques have been utilized. Leakage has resulted in minor abdominal pain; no patient has required operation due to percutaneous cecostomy. All procedures were successful and accomplished their goal

  20. Facility target insert shielding assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

  1. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    International Nuclear Information System (INIS)

    Dasgupta, Niloy; Lungren, Matthew P.; Patel, Manish N.; Racadio, John M.; Johnson, Neil D.

    2016-01-01

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  2. Comparison of complications between pediatric peripherally inserted central catheter placement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dasgupta, Niloy; Lungren, Matthew P. [Lucile Packard Children' s Hospital Stanford, Department of Radiology, Palo Alto, CA (United States); Patel, Manish N.; Racadio, John M.; Johnson, Neil D. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-09-15

    Peripherally inserted central catheter (PICC) is among the most common procedures performed in children in the hospital setting. PICC insertion can be simplified with the use of a sheathed needle as an alternative to the modified Seldinger technique. To retrospectively evaluate PICC placement for the technique used and the incidence of complications at a large pediatric tertiary care center. We retrospectively reviewed all PICC placements at a single institution over a 4-year period. We reviewed patient records for demographic data, PICC placement technique, catheter size and number of lumens, and the incidence of complications (i.e. multiple attempted puncture sites, phlebitis and vessel thrombosis). We analyzed complication rates between two placement techniques using a chi-square test. We identified 8,816 successful PICC placements, 4,749 (53.9%) in males and 4,067 (46.1%) in females. The average age of the patients for which a line was placed was 5.6 years (range 1 day to 45 years). A direct sheathed needle puncture technique was used in 8,362 (94.9%) placements and a modified Seldinger technique was used in 454 (5.1%). Complications occurred in 312 (3.7%) of direct sheathed needle puncture placements versus 17 (3.7%) of modified Seldinger placements (P = 0.99). Multiple puncture sites were required in 175 (2.1%) attempted direct sheathed needle puncture placements compared with 8 (1.7%) attempted modified Seldinger placements (P = 0.63). Phlebitis occurred in 94 (1.1%) direct sheathed needle puncture lines versus 5 (1.1%) modified Seldinger placed lines (P = 0.96). Vessel thrombosis occurred in 43 (0.5%) direct sheathed needle puncture lines versus 4 (0.9%) modified Seldinger placed lines (P = 0.30). The direct peel-away sheathed needle vessel puncture technique and the modified Seldinger technique used to place PICC lines in children have similar complication rates. (orig.)

  3. Percutaneous dilatational tracheostomy for ICU patients with severe brain injury

    Directory of Open Access Journals (Sweden)

    Guo Dongyuan

    2014-12-01

    Full Text Available 【Abstract】Objective: To sum up our experience in percutaneous dilatational tracheostomy (PDT in ICU patient with severe brain injury. Methods: Between November 2011 and April 2014, PDTs were performed on 32 severe brain injury patients in ICU by a team of physicians and intensivists. The success rate, effi cacy, safety, and complications including stomal infection and bleeding, paratracheal insertion, pneumothorax, pneumomediastinum, tracheal laceration, as well as clinically significant tracheal stenosis were carefully monitored and recorded respectively. Results: The operations took 4-15 minutes (mean 9.1 minutes±4.2 minutes. Totally 4 cases suffered from complications in the operations: 3 cases of stomal bleeding, and 1 case of intratracheal bloody secretion, but none required intervention. Paratracheal insertion, pneumothorax, pneumomediastinum, tracheal laceration, or clinically signifi cant tracheal stenosis were not found in PDT patients. There was no procedure-related death occurring during or after PDT. Conclusion: Our study demonstrats that PDT is a safe, highly effective, and minimally invasive procedure. The appropriate sedation and airway management perioperatively help to reduce complication rates. PDT should be performed or supervised by a team of physicians with extensive experience in this procedure, and also an intensivist with experience in diffi cult airway management. Key words: Brain injuries; Percutaneous dilatational tracheostomy; ICU

  4. Direction of catheter insertion and the incidence of paresthesia during continuous epidural anesthesia in the elderly patients

    Science.gov (United States)

    Kim, Jong-Hak; Lee, Jun Seop

    2013-01-01

    Background Continuous epidural anesthesia is useful for endoscopic urologic surgery, as mostly performed in the elderly patients. In such a case, it is necessary to obtain successful sacral anesthesia, and the insertion of epidural catheter in the caudad direction may be needed. However, continuous epidural catherization has been related to paresthesias. This study aimed to evaluate the effects of the direction of the catheter insertion on the incidence of paresthesias in the elderly patients. Methods Two hundred elderly patients scheduled for endoscopic urologic surgery were enrolled. The epidural catheter was inserted at L2-3, L3-4, and L4-5 using the Tuohy needle. In Group I (n = 100), the Tuohy needle with the bevel directed the cephalad during the catheter insertion. In Group II (n = 100), it directed the caudad. During the catheter insertion, an anesthesiologist evaluated the presence of paresthesias and the ease or difficulty during the catheter insertion. Results In Group I (n = 97), 15.5% of the patients had paresthesias versus 18.4% in Group II (n = 98), and there was no significant difference between the two groups. In paresthesia depending on the insertion site and the ease or difficulty during the catheter insertion, there were no significant differences between the two groups. Conclusions Our results concluded that the direction of epidural catheter insertion did not significantly influence the incidence of paresthesias in the elderly patients. PMID:23741568

  5. Percutaneous gastrostomy tube placement in patients with ventriculoperitoneal shunts

    Energy Technology Data Exchange (ETDEWEB)

    Sane, S.S.; Towbin, A.; Bergey, E.A.; Kaye, R.D.; Fitz, C.R.; Albright, L.; Towbin, R.B. [Department of Radiology, Children`s Hospital of Pittsburgh, 3705 Fifth Avenue, Pittsburgh, PA 15213 (United States)

    1998-07-01

    Objective. The purpose of this study is to determine the risk of CNS and/or peritoneal infection in children with ventriculoperitoneal shunts in whom a percutaneous gastrostomy tube is placed. Materials and methods. We placed 205 gastrostomy or gastrojejunostomy tubes from January of 1991 to December 1996. Twenty-three patients (10 boys, 13 girls) had ventriculoperitoneal shunts at the time of placement. All shunts were placed at least 1 month prior to placement of the gastrostomy tube. The patients ranged in age from 8 months to 16 years with a mean age of 6 years, 9 months. Patient weight ranged from 2 kg to 60 kg. All 23 children required long-term nutritional support due to severe neurologic impairment. No prophylactic antibiotics were given prior to the procedure. Of the patients, 21/23 had a 14-F Sacks-Vine gastrostomy tube with a fixed terminal retention device inserted, using percutaneous fluoroscopic antegrade technique. Two of the 23 patients had a Ross 14-F Flexi-flo gastrostomy tube which required a retrograde technique due to a small caliber esophagus in these children. Results. All 23 children had technically successful placements of percutaneous gastrostomy (7) or gastrojejunostomy (16) tubes. Of the children, 21/23 (91 %) had no complications from the procedure. Two of 23 (9 %) patients demonstrated signs of peritonitis after placement of their gastrostomy tubes and subsequently had shunt infections. In both, children CSF culture grew gram-positive cocci. The antegrade technique was used in both children who developed peritonitis. Conclusion. Our study indicates children with ventriculoperitoneal shunts who undergo percutaneous gastrostomy are at greater risk for infection and subsequent shunt malfunction. Therefore, we recommend prophylactic antibiotic therapy to cover for skin and oral flora. (orig.) With 1 fig., 7 refs.

  6. Lung abscess; Percutaneous catheter therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ha, H.K. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Kang, M.W. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Park, J.M. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Yang, W.J. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Shinn, K.S. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Bahk, Y.W. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of))

    1993-07-01

    Lung abscess was successfully treated with percutaneous drainage in 5 of 6 patients. Complete abscess resolution occurred in 4 patients, partial resolution in one, and no response in one. The duration of drainage ranged from 7 to 18 days (mean 15.5 days) in successful cases. The failure of drainage in one neurologicall impaired patient was attributed to persistent aspiration. In 2 patients, concurrent pleural empyema was also cured. CT provided the anatomic details necessary for choosing the puncture site and avoiding puncture of the lung parenchyma. Percutaneous catheter drainage is a safe and effective method for treating lung abscess. (orig.).

  7. Percutaneous drainage of lung abscess