WorldWideScience

Sample records for peep positive-end expiratory

  1. Control of positive end-expiratory pressure (PEEP for small animal ventilators

    Directory of Open Access Journals (Sweden)

    Leão Nunes Marcelo V

    2010-07-01

    Full Text Available Abstract Background The positive end-expiratory pressure (PEEP for the mechanical ventilation of small animals is frequently obtained with water seals or by using ventilators developed for human use. An alternative mechanism is the use of an on-off expiratory valve closing at the moment when the alveolar pressure is equal to the target PEEP. In this paper, a novel PEEP controller (PEEP-new and the PEEP system of a commercial small-animal ventilator, both based on switching an on-off valve, are evaluated. Methods The proposed PEEP controller is a discrete integrator monitoring the error between the target PEEP and the airways opening pressure prior to the onset of an inspiratory cycle. In vitro as well as in vivo experiments with rats were carried out and the PEEP accuracy, settling time and under/overshoot were considered as a measure of performance. Results The commercial PEEP controller did not pass the tests since it ignores the airways resistive pressure drop, resulting in a PEEP 5 cmH2O greater than the target in most conditions. The PEEP-new presented steady-state errors smaller than 0.5 cmH2O, with settling times below 10 s and under/overshoot smaller than 2 cmH2O. Conclusion The PEEP-new presented acceptable performance, considering accuracy and temporal response. This novel PEEP generator may prove useful in many applications for small animal ventilators.

  2. Differential Effects of Intraoperative Positive End-expiratory Pressure (PEEP) on Respiratory Outcome in Major Abdominal Surgery Versus Craniotomy

    DEFF Research Database (Denmark)

    de Jong, Myrthe A C; Ladha, Karim S; Melo, Marcos F Vidal

    2015-01-01

    OBJECTIVES: In this study, we examined whether (1) positive end-expiratory pressure (PEEP) has a protective effect on the risk of major postoperative respiratory complications in a cohort of patients undergoing major abdominal surgeries and craniotomies, and (2) the effect of PEEP is differed......: Within the entire study population (major abdominal surgeries and craniotomies), we found an association between application of PEEP ≥5 cmH2O and a decreased risk of postoperative respiratory complications compared with PEEP 5 cmH2O was associated with a significant lower...... undergoing major abdominal surgery. Our data suggest that default mechanical ventilator settings should include PEEP of 5-10 cmH2O during major abdominal surgery....

  3. The effect of positive end-expiratory pressure on pulse pressure ...

    African Journals Online (AJOL)

    The effect of positive end-expiratory pressure on pulse pressure variation. FJ Smith, M Geyser, I Schreuder, PJ Becker. Abstract. Objectives: To determine the effect of different levels of positive end-expiratory pressure (PEEP) on pulse pressure variation (PPV). Design: An observational study. Setting: Operating theatres of a ...

  4. Pharmacologic Interventions to Improve Splanchnic Oxygenation During Ventilation with Positive End-Expiratory Pressure

    NARCIS (Netherlands)

    Fournell, A.; Scheeren, T. W. L.; Picker, O.; Schwarte, L. A.; Wolf, M; Bucher, HU; Rudin, M; VanHuffel, S; Wolf, U; Bruley, DF; Harrison, DK

    2012-01-01

    Mechanical ventilation with positive end-expiratory pressure (PEEP) is an indispensable tool in the management of respiratory failure to preserve or improve lung function and systemic oxygenation. However, PEEP per se may also, as has been shown in experimental animals, impair regional

  5. Effects of positive end-expiratory pressure on renal function.

    Science.gov (United States)

    Järnberg, P O; de Villota, E D; Eklund, J; Granberg, P O

    1978-01-01

    The effects were studied positive end-expiratory pressure (PEEP) on renal function in eight patients with acute respiratory failure, requiring mechanical ventilation. On application of PEEP + 10 cm H2O, central venous pressure increased, systolic blood pressure decreased, urine flow and PAH-clearance were reduced, while inulin clearance remained stable. There was a marked increase in fractional sodium reabsorption and a concurrent decrease in fractional osmolal excretion. Fractional free-water clearance and the ratio UOsm/POsm did change.

  6. Setting individualized positive end-expiratory pressure level with a positive end-expiratory pressure decrement trial after a recruitment maneuver improves oxygenation and lung mechanics during one-lung ventilation.

    Science.gov (United States)

    Ferrando, Carlos; Mugarra, Ana; Gutierrez, Andrea; Carbonell, Jose Antonio; García, Marisa; Soro, Marina; Tusman, Gerardo; Belda, Francisco Javier

    2014-03-01

    We investigated whether individualized positive end-expiratory pressure (PEEP) improves oxygenation, ventilation, and lung mechanics during one-lung ventilation compared with standardized PEEP. Thirty patients undergoing thoracic surgery were randomly allocated to the study or control group. Both groups received an alveolar recruitment maneuver at the beginning and end of one-lung ventilation. After the alveolar recruitment maneuver, the control group had their lungs ventilated with a 5 cm·H2O PEEP, while the study group had their lungs ventilated with an individualized PEEP level determined by a PEEP decrement trial. Arterial blood samples, lung mechanics, and volumetric capnography were recorded at multiple timepoints throughout the procedure. The individualized PEEP values in study group were higher than the standardized PEEP values (10 ± 2 vs 5 cm·H2O; P decrement trial than with a standardized 5 cm·H2O of PEEP.

  7. FCT (functional computed tomography) evaluation of the lung volumes at different PEEP (positive-end expiratory pressure) ventilation pattern, in mechanical ventilated patients

    International Nuclear Information System (INIS)

    Papi, M.G.; Di Segni, R.; Mazzetti, G.; Staffa, F.; Conforto, F.; Calimici, R.; Salvi, A.; Matteucci, G.

    2007-01-01

    Purpose To evaluate with FCT (functional computed tomography) total lung volume and fractional lung volumes at different PEEP (positive end expiratory pressure) values in acute mechanically ventilated patients. Methods Nine ICU (intensive care unity) patients (1 lung pneumonia, 2 polytrauma, 2 sepsis, 3 brain surgery, 1 pulmonary embolism); mean age 48 ± 15 years, 6 male, 3 female; GE 16 MDCT scan was performed with acquisition from apex to diaphragma in seven seca at different PEEP values. Raw CT data were analysed by an advantage workstation to obtain volume density masks and histograms of both lungs and each lung and these density ranges were applied: - 1000 - 950 hyper-ventilated lung, -900 - 650 well aerated lung, -950 - 500 all aerated lung, -500 + 200 lung tissue. Total and fractional lung volumes, Hounsfield unit (HU) were calculated and compared at different PEEP values (0, 5, 10, 15 cm H 2 O). In four patients lung volumes were compared between the more and the less involved lung at increased PEEP. Statistic analysis: comparison means-medians tests. Results Data calculated at five PEEP showed unexpected decrease of total lung volume and increase of lung density (HU); proportionally no significant improvement of oxigenation. (orig.)

  8. FCT (functional computed tomography) evaluation of the lung volumes at different PEEP (positive-end expiratory pressure) ventilation pattern, in mechanical ventilated patients

    Energy Technology Data Exchange (ETDEWEB)

    Papi, M.G.; Di Segni, R.; Mazzetti, G.; Staffa, F. [Dept. of Radiology, S. Giovanni HS, Rome (Italy); Conforto, F.; Calimici, R.; Salvi, A. [Dept. of Anesthesiology, S. Giovanni HS, Rome (Italy); Matteucci, G. [Dept. of Pneumology, S. Giovanni HS, Rome (Italy)

    2007-06-15

    Purpose To evaluate with FCT (functional computed tomography) total lung volume and fractional lung volumes at different PEEP (positive end expiratory pressure) values in acute mechanically ventilated patients. Methods Nine ICU (intensive care unity) patients (1 lung pneumonia, 2 polytrauma, 2 sepsis, 3 brain surgery, 1 pulmonary embolism); mean age 48 {+-} 15 years, 6 male, 3 female; GE 16 MDCT scan was performed with acquisition from apex to diaphragma in seven seca at different PEEP values. Raw CT data were analysed by an advantage workstation to obtain volume density masks and histograms of both lungs and each lung and these density ranges were applied: - 1000 - 950 = hyper-ventilated lung, -900 - 650 well aerated lung, -950 - 500 all aerated lung, -500 + 200 lung tissue. Total and fractional lung volumes, Hounsfield unit (HU) were calculated and compared at different PEEP values (0, 5, 10, 15 cm H{sub 2}O). In four patients lung volumes were compared between the more and the less involved lung at increased PEEP. Statistic analysis: comparison means-medians tests. Results Data calculated at five PEEP showed unexpected decrease of total lung volume and increase of lung density (HU); proportionally no significant improvement of oxigenation. (orig.)

  9. Effects of positive end-expiratory pressure on arthroscopic shoulder surgery under general anesthesia.

    Science.gov (United States)

    Ersoy, Ayşın; Çakırgöz, Mensure; Ervatan, Zekeriya; Kıran, Özlem; Türkmen, Aygen; Esenyel, Cem Zeki

    2016-01-01

    Our study is a prospective, randomized study on patients undergoing arthroscopic shoulder surgery in the beach-chair position to evaluate the effects of positive end-expiratory pressure (PEEP) on hemodynamic stability, providing a bloodless surgical field and surgical satisfaction. Fifty patients were divided into two groups. Group I (n=25) had zero end-expiratory pressure (ZEEP) administered under general anesthesia, and group II (n=25) had +5 PEEP administered. During surgery, intraarticular hemorrhage and surgical satisfaction were evaluated on a scale of 0-10. During surgery, at the 5th, 30th, 60th, and 90th minutes and at the end of surgery, heart rate, mean arterial pressure (MAP), and positive inspiratory pressure were recorded. At the end of the surgery, the amount of bleeding and duration of the operation were recorded. In group I, the duration of operation and amount of bleeding were found to be significantly greater than those in group II (pshoulder surgery in the beach-chair position reduces the amount of hemorrhage in the surgical field and thus increases surgical satisfaction without requiring the creation of controlled hypotension.

  10. Interaction between intra-abdominal pressure and positive-end expiratory pressure

    Directory of Open Access Journals (Sweden)

    Jamili Anbar Torquato

    2009-02-01

    Full Text Available OBJECTIVE: The aim of this study was to quantify the interaction between increased intra-abdominal pressure and Positive-End Expiratory Pressure. METHODS: In 30 mechanically ventilated ICU patients with a fixed tidal volume, respiratory system plateau and abdominal pressure were measured at a Positive-End Expiratory Pressure level of zero and 10 cm H2O. The measurements were repeated after placing a 5 kg weight on the patients' belly. RESULTS: After the addition of 5 kg to the patients' belly at zero Positive-End Expiratory Pressure, both intra-abdominal pressure (p<0.001 and plateau pressures (p=0.005 increased significantly. Increasing the Positive-End Expiratory Pressure levels from zero to 10 cm H2O without weight on the belly did not result in any increase in intra-abdominal pressure (p=0.165. However, plateau pressures increased significantly (p< 0.001. Increasing Positive-End Expiratory Pressure from zero to 10 cm H2O and adding 5 kg to the belly increased intra-abdominal pressure from 8.7 to 16.8 (p<0.001 and plateau pressure from 18.26 to 27.2 (p<0.001. Maintaining Positive-End Expiratory Pressure at 10 cm H2O and placing 5 kg on the belly increased intra-abdominal pressure from 12.3 +/- 1.7 to 16.8 +/- 1.7 (p<0.001 but did not increase plateau pressure (26.6+/-1.2 to 27.2 +/-1.1 -p=0.83. CONCLUSIONS: The addition of a 5kg weight onto the abdomen significantly increased both IAP and the airway plateau pressure, confirming that intra-abdominal hypertension elevates the plateau pressure. However, plateau pressure alone cannot be considered a good indicator for the detection of elevated intra-abdominal pressure in patients under mechanical ventilation using PEEP. In these patients, the intra-abdominal pressure must also be measured.

  11. Respiratory System Mechanics During Low Versus High Positive End-Expiratory Pressure in Open Abdominal Surgery: A Substudy of PROVHILO Randomized Controlled Trial

    NARCIS (Netherlands)

    D'Antini, Davide; Huhle, Robert; Herrmann, Jacob; Sulemanji, Demet S.; Oto, Jun; Raimondo, Pasquale; Mirabella, Lucia; Hemmes, Sabrine N. T.; Schultz, Marcus J.; Pelosi, Paolo; Kaczka, David W.; Vidal Melo, Marcos Francisco; Gama de Abreu, Marcelo; Cinnella, Gilda

    2018-01-01

    In the 2014 PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure (PROVHILO) trial, intraoperative low tidal volume ventilation with high positive end-expiratory pressure (PEEP = 12 cm H2O) and lung recruitment maneuvers did not decrease postoperative pulmonary complications

  12. Positive end-expiratory pressure improves survival in a rodent model of cardiopulmonary resuscitation using high-dose epinephrine.

    LENUS (Irish Health Repository)

    McCaul, Conán

    2009-10-01

    Multiple interventions have been tested in models of cardiopulmonary resuscitation (CPR) to optimize drug use, chest compressions, and ventilation. None has studied the effects of positive end-expiratory pressure (PEEP) on outcome. We hypothesized that because PEEP can reverse pulmonary atelectasis, lower pulmonary vascular resistance, and potentially improve cardiac output, its use during CPR would increase survival.

  13. Positive end-expiratory pressure increases pulmonary clearance of inhaled 99mTc-DTPA in nonsmokers but not in healthy smokers

    International Nuclear Information System (INIS)

    Nolop, K.B.; Braude, S.; Royston, D.; Maxwell, D.L.; Hughes, J.M.B.

    1987-01-01

    Positive end-expiratory pressure (PEEP) is widely used in the treatment of severe pulmonary oedema, although its effects on the clearance of water and small solutes from alveolus to blood are not well characterized. We studied the effect of the application of 10 cmH 2 O of PEEP on the flux of inhaled 99 mTc-diethylene-triamine-penta-acetic acid (DTPA) from lung to blood in six healthy smoking and six nonsmoking subjects. The rate of flux was corrected for possible changes in pulmonary blood volume during PEEP by use of an intravenous injection of 99m Tc-DTPA. The baseline clearance rate (K,%.min -1 ) for nonsmokers was 1.48±0.12 (mean±SE) and increased to 2.40±0.29 during PEEP (p<0.05). In contrast, the mean clearance rate for smokers was 3.26±0.82 at baseline and 3.03±0.82 during PEEP (p=NS). The application of positive end-expiratory pressure appears to increase alveolar solute flux in nonsmokers but not in smokers, suggesting that the pathway for solute clearance in smokers is governed by different rate-limiting steps to those of nonsmokers

  14. Intratidal recruitment/derecruitment persists at low and moderate positive end-expiratory pressure in paediatric patients.

    Science.gov (United States)

    Wirth, Steffen; Artner, Lisa; Broß, Tobias; Lozano-Zahonero, Sara; Spaeth, Johannes; Schumann, Stefan

    2016-12-01

    In paediatric patients positive end-expiratory pressure (PEEP) is traditionally set lower than in adults. We investigated whether moderately higher PEEP improves respiratory mechanics and regional ventilation. Therefore, 40 children were mechanically ventilated with PEEP 2 and 5cmH 2 O. Volume-dependent compliance profiles were analysed as a measure of intratidal recruitment/derecruitment. Regional ventilation was assessed using electrical impedance tomography. Mean compliance was 17.9±9.9mLcmH 2 O -1 (PEEP 2cmH 2 O), and 19.0±10.9mLcmH 2 O -1 (PEEP 5 cmH 2 O, pventilation. In conclusion, mechanically ventilated paediatric patients undergo intratidal recruitment/derecruitment which occurs more prominently in younger than in older children. A PEEP of 5cmH 2 O does not fully prevent intratidal recruitment/derecruitment but homogenizes regional ventilation in comparison to 2cmH 2 O. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Respiratory System Mechanics During Low Versus High Positive End-Expiratory Pressure in Open Abdominal Surgery: A Substudy of PROVHILO Randomized Controlled Trial.

    Science.gov (United States)

    D'Antini, Davide; Huhle, Robert; Herrmann, Jacob; Sulemanji, Demet S; Oto, Jun; Raimondo, Pasquale; Mirabella, Lucia; Hemmes, Sabrine N T; Schultz, Marcus J; Pelosi, Paolo; Kaczka, David W; Vidal Melo, Marcos Francisco; Gama de Abreu, Marcelo; Cinnella, Gilda

    2018-01-01

    In the 2014 PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure (PROVHILO) trial, intraoperative low tidal volume ventilation with high positive end-expiratory pressure (PEEP = 12 cm H2O) and lung recruitment maneuvers did not decrease postoperative pulmonary complications when compared to low PEEP (0-2 cm H2O) approach without recruitment breaths. However, effects of intraoperative PEEP on lung compliance remain poorly understood. We hypothesized that higher PEEP leads to a dominance of intratidal overdistension, whereas lower PEEP results in intratidal recruitment/derecruitment (R/D). To test our hypothesis, we used the volume-dependent elastance index %E2, a respiratory parameter that allows for noninvasive and radiation-free assessment of dominant overdistension and intratidal R/D. We compared the incidence of intratidal R/D, linear expansion, and overdistension by means of %E2 in a subset of the PROVHILO cohort. In 36 patients from 2 participating centers of the PROVHILO trial, we calculated respiratory system elastance (E), resistance (R), and %E2, a surrogate parameter for intratidal overdistension (%E2 > 30%) and R/D (%E2 mechanical ventilation with protective tidal volumes in patients undergoing open abdominal surgery, lung recruitment followed by PEEP of 12 cm H2O decreased the incidence of intratidal R/D and did not worsen overdistension, when compared to PEEP ≤2 cm H2O.

  16. Effects of Inhaled Fenoterol and Positive End-Expiratory Pressure on the Respiratory Mechanics of Patients with Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Claude Guerin

    2005-01-01

    Full Text Available BACKGROUND: During acute ventilatory failure in patients with chronic obstructive pulmonary disease (COPD, applying external positive end-expiratory pressure (PEEPe will reopen small airways and, thus, may enhance peripheral deposition as well as the physiological effects of inhaled beta-2 agonists.

  17. Differing responses in right and left ventricular filling, loading and volumes during positive end-expiratory pressure

    International Nuclear Information System (INIS)

    Schulman, D.S.; Biondi, J.W.; Matthay, R.A.; Zaret, B.L.; Soufer, R.

    1989-01-01

    Using a combined hemodynamic and radionuclide technique, 20 patients with varied ventricular function were evaluated during positive end-expiratory pressure (PEEP) application. Left ventricular (LV) and right ventricular (RV) ejection fractions and cardiac output were measured, and ventricular volumes were derived. Seven patients (group 1) who had an increase in LV end-diastolic volume with PEEP and 13 patients (group 2) who had the more typical response, a decrease in LV end-diastolic volume with PEEP, were identified. Compared with group 2, group 1 patients had a higher incidence of coronary artery disease (5 of 7 vs 1 of 13, p less than 0.005) and lower cardiac output (3.9 +/- 1.6 vs 9.1 +/- 3.2 liters/min, p less than 0.005), LV ejection fraction (27 +/- 13 vs 51 +/- 21%, p less than 0.05), RV ejection fraction (15 +/- 6 vs 32 +/- 8%, p less than 0.005) and peak filling rate (1.32 +/- 0.43 vs 3.51 +/- 1.70 end-diastolic volumes/s, p less than 0.05). LV and RV volumes increased and peak filling rate decreased with PEEP in group 1, whereas in group 2 LV volume decreased and RV volume and peak filling rate remained unchanged. Using stepwise regression analysis, the change in LV volume with PEEP was related directly to baseline systemic vascular resistance and inversely to baseline blood pressure. Similarly, the change in peak filling rate with PEEP was inversely related to the change in RV end-diastolic volume. Thus, the hemodynamic response to PEEP is heterogeneous and may be related to LV ischemia

  18. Hemodynamic responses to external counterbalancing of auto-positive end-expiratory pressure in mechanically ventilated patients with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Baigorri, F; de Monte, A; Blanch, L; Fernández, R; Vallés, J; Mestre, J; Saura, P; Artigas, A

    1994-11-01

    To study the effect of positive end-expiratory pressure (PEEP) on right ventricular hemodynamics and ejection fraction in patients with chronic obstructive pulmonary disease and positive alveolar pressure throughout expiration by dynamic hyperinflation (auto-PEEP). Open, prospective, controlled trial. General intensive care unit of a community hospital. Ten patients sedated and paralyzed with an acute exacerbation of chronic obstructive pulmonary disease undergoing mechanical ventilation. Insertion of a pulmonary artery catheter modified with a rapid response thermistor and a radial arterial catheter. PEEP was then increased from 0 (PEEP 0) to auto-PEEP level (PEEP = auto-PEEP) and 5 cm H2O above that (PEEP = auto-PEEP +5). At each level of PEEP, airway pressures, flow and volume, hemodynamic variables (including right ventricular ejection fraction by thermodilution technique), and blood gas analyses were recorded. The mean auto-PEEP was 6.6 +/- 2.8 cm H2O and the total PEEP reached was 12.2 +/- 2.4 cm H2O. The degree of lung inflation induced by PEEP averaged 145 +/- 87 mL with PEEP = auto-PEEP and 495 +/- 133 mL with PEEP = auto-PEEP + 5. The PEEP = auto-PEEP caused a right ventricular end-diastolic pressure increase, but there was no other significant hemodynamic change. With PEEP = auto-PEEP + 5, there was a significant increase in intravascular pressures; this amount of PEEP reduced cardiac output (from 4.40 +/- 1.38 L/min at PEEP 0 to 4.13 +/- 1.48 L/min; p 10% in only five cases and this group of patients had significantly lower right ventricular volumes than the group with less cardiac output variation (right ventricular end-diastolic volume: 64 +/- 9 vs. 96 +/- 26 mL/m2; right ventricular end-systolic volume: 38 +/- 6 vs. 65 +/- 21 mL/m2; p < .05) without significant difference in the other variables that were measured. Neither right ventricular ejection fraction nor right ventricle volumes changed as PEEP increased, but there were marked interpatient

  19. Positive end-expiratory pressure improves gas exchange and pulmonary mechanics during partial liquid ventilation.

    Science.gov (United States)

    Kirmse, M; Fujino, Y; Hess, D; Kacmarek, R M

    1998-11-01

    Partial liquid ventilation (PLV) with perflubron (PFB) has been proposed as an adjunct to the current therapies for the acute respiratory distress syndrome (ARDS). Because PFB has been also referred to as "liquid PEEP," distributing to the most gravity-dependent regions of the lung, less attention has been paid to the amount of applied positive end-expiratory pressure (PEEP). We hypothesized that higher PEEP levels than currently applied are needed to optimize gas exchange, and that the lower inflection point (LIP) of the pressure-volume curve could be used to estimate the amount of PEEP needed when the lung is filled with PFB. Lung injury was induced in 23 sheep by repeated lung lavage with warmed saline until the PaO2/FIO2 ratio fell below 150. Five sheep were used to investigate the change of the LIP when the lung was filled with PFB in increments of 5 ml/kg/body weight to a total of 30 ml/kg/body weight. To evaluate the impact of PEEP set at LIP +1 cm H2O we randomized an additional 15 sheep to three groups with different doses (7.5 ml, 15 ml, 30 ml/kg/body weight) of PFB. In random order a PEEP of 5 cm H2O or PEEP at LIP +1 cm H2O was applied. The LIP decreased with incremental filling of PFB to a minimum at 10 ml (p PFB shifts the LIP to the left, and that setting PEEP at LIP +1 cm H2O improves gas exchange at moderate to high doses of PFB.

  20. Relationship of end-expiratory pressure, lung volume, and /sup 99m/Tc-DTPA clearance

    International Nuclear Information System (INIS)

    Cooper, J.A.; van der Zee, H.; Line, B.R.; Malik, A.B.

    1987-01-01

    We investigated the dose-response effect of positive end-expiratory pressure (PEEP) and increased lung volume on the pulmonary clearance rate of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Clearance of lung radioactivity was expressed as percent decrease per minute. Base-line clearance was measured while anesthetized sheep (n = 20) were ventilated with 0 cmH 2 O end-expiratory pressure. Clearance was remeasured during ventilation at 2.5, 5, 10, 15, or 20 cmH 2 O PEEP. Further studies showed stepwise increases in functional residual capacity (FRC) (P less than 0.05) measured at 0, 2.5, 5, 10, 15, and 20 cmH 2 O PEEP. At 2.5 cmH 2 O PEEP, the clearance rate was not different from that at base line (P less than 0.05), although FRC was increased from base line. Clearance rate increased progressively with increasing PEEP at 5, 10, and 15 cmH 2 O (P less than 0.05). Between 15 and 20 cmH 2 O PEEP, clearance rate was again unchanged, despite an increase in FRC. The pulmonary clearance of aerosolized /sup 99m/Tc-DTPA shows a sigmoidal response to increasing FRC and PEEP, having both threshold and maximal effects. This relationship is most consistent with the hypothesis that alveolar epithelial permeability is increased by lung inflation

  1. Associations between positive end-expiratory pressure and outcome of patients without ARDS at onset of ventilation: a systematic review and meta-analysis of randomized controlled trials

    NARCIS (Netherlands)

    Serpa Neto, Ary; Filho, Roberto Rabello; Cherpanath, Thomas; Determann, Rogier; Dongelmans, Dave A.; Paulus, Frederique; Tuinman, Pieter Roel; Pelosi, Paolo; de Abreu, Marcelo Gama; Schultz, Marcus J.

    2016-01-01

    The aim of this investigation was to compare ventilation at different levels of positive end-expiratory pressure (PEEP) with regard to clinical important outcomes of intensive care unit (ICU) patients without acute respiratory distress syndrome (ARDS) at onset of ventilation. Meta-analysis of

  2. Influence of Positive End-Expiratory Pressure on Myocardial Strain Assessed by Speckle Tracking Echocardiography in Mechanically Ventilated Patients

    Directory of Open Access Journals (Sweden)

    Federico Franchi

    2013-01-01

    Full Text Available Purpose. The effects of mechanical ventilation (MV on speckle tracking echocardiography- (STE-derived variables are not elucidated. The aim of the study was to evaluate the effects of positive end-expiratory pressure (PEEP ventilation on 4-chamber longitudinal strain (LS analysis by STE. Methods. We studied 20 patients admitted to a mixed intensive care unit who required intubation for MV and PEEP titration due to hypoxia. STE was performed at three times: (T1 PEEP = 5 cmH2O; (T2 PEEP = 10 cmH2O; and (T3 PEEP = 15 cmH2O. STE analysis was performed offline using a dedicated software (XStrain MyLab 70 Xvision, Esaote. Results. Left peak atrial-longitudinal strain (LS was significantly reduced from T1 to T2 and from T2 to T3 (. Right peak atrial-LS and right ventricular-LS showed a significant reduction only at T3 (. Left ventricular-LS did not change significantly during titration of PEEP. Cardiac chambers’ volumes showed a significant reduction at higher levels of PEEP (. Conclusions. We demonstrated for the first time that incremental PEEP affects myocardial strain values obtained with STE in intubated critically ill patients. Whenever performing STE in mechanically ventilated patients, care must be taken when PEEP is higher than 10 cmH2O to avoid misinterpreting data and making erroneous decisions.

  3. Effects of positive end-expiratory pressure on intraoperative core temperature in patients undergoing posterior spine surgery: prospective randomised trial.

    Science.gov (United States)

    Seo, Hyungseok; Do Son, Je; Lee, Hyung-Chul; Oh, Hyung-Min; Jung, Chul-Woo; Park, Hee-Pyoung

    2018-03-01

    Objective Positive end-expiratory pressure (PEEP) causes carotid baroreceptor unloading, which leads to thermoregulatory peripheral vasoconstriction. However, the effects of PEEP on intraoperative thermoregulation in the prone position remain unknown. Methods Thirty-seven patients undergoing spine surgery in the prone position were assigned at random to receive either 10 cmH 2 O PEEP (Group P) or no PEEP (Group Z). The primary endpoint was core temperature 180 minutes after intubation. Secondary endpoints were delta core temperature (difference in core temperature between 180 minutes and immediately after tracheal intubation), incidence of intraoperative hypothermia (core temperature of peripheral vasoconstriction-related data. Results The median [interquartile range] core temperature 180 minutes after intubation was 36.1°C [35.9°C-36.2°C] and 36.0°C [35.9°C-36.4°C] in Groups Z and P, respectively. The delta core temperature and incidences of intraoperative hypothermia and peripheral vasoconstriction were not significantly different between the two groups. The peripheral vasoconstriction threshold (36.2°C±0.5°C vs. 36.7°C±0.6°C) was lower and the onset of peripheral vasoconstriction (66 [60-129] vs. 38 [28-70] minutes) was slower in Group Z than in Group P. Conclusions Intraoperative PEEP did not reduce the core temperature decrease in the prone position, although it resulted in an earlier onset and higher threshold of peripheral vasoconstriction.

  4. Positive end expiratory pressure during one-lung ventilation: Selecting ideal patients and ventilator settings with the aim of improving arterial oxygenation

    Directory of Open Access Journals (Sweden)

    Hoftman Nir

    2011-01-01

    Full Text Available The efficacy of positive end-expiratory pressure (PEEP in treating intraoperative hypoxemia during one-lung ventilation (OLV remains in question given conflicting results of prior studies. This study aims to (1 evaluate the efficacy of PEEP during OLV, (2 assess the utility of preoperative predictors of response to PEEP, and (3 explore optimal intraoperative settings that would maximize the effects of PEEP on oxygenation. Forty-one thoracic surgery patients from a single tertiary care university center were prospectively enrolled in this observational study. After induction of general anesthesia, a double-lumen endotracheal tube was fiberoptically positioned and OLV initiated. Intraoperatively, PEEP = 5 and 10 cmH 2 O were sequentially applied to the ventilated lung during OLV. Arterial oxygenation, cardiovascular performance parameters, and proposed perioperative variables that could predict or enhance response to PEEP were analysed. T-test and c2 tests were utilized for continuous and categorical variables, respectively. Multivariate analyses were carried out using a classification tree model of binary recursive partitioning. PEEP improved arterial oxygenation by ≥20% in 29% of patients (n = 12 and failed to do so in 71% (n = 29; however, no cardiovascular impact was noted. Among the proposed clinical predictors, only intraoperative tidal volume per kilogram differed significantly between responders to PEEP and non-responders (mean 6.6 vs. 5.7 ml/kg, P = 0.013; no preoperative variable predicted response to PEEP. A multivariate analysis did not yield a clinically significant model for predicting PEEP responsiveness. PEEP improved oxygenation in a subset of patients; larger, although still protective tidal volumes favored a positive response to PEEP. No preoperative variables, however, could be identified as reliable predictors for PEEP responders.

  5. Assessment of Factors Related to Auto-PEEP.

    Science.gov (United States)

    Natalini, Giuseppe; Tuzzo, Daniele; Rosano, Antonio; Testa, Marco; Grazioli, Michele; Pennestrì, Vincenzo; Amodeo, Guido; Marsilia, Paolo F; Tinnirello, Andrea; Berruto, Francesco; Fiorillo, Marialinda; Filippini, Matteo; Peratoner, Alberto; Minelli, Cosetta; Bernardini, Achille

    2016-02-01

    Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development. One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen. The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio 15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1). Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values. Copyright © 2016 by Daedalus Enterprises.

  6. Application of dead space fraction to titrate optimal positive end-expiratory pressure in an ARDS swine model.

    Science.gov (United States)

    Bian, Weishuai; Chen, Wei; Chao, Yangong; Wang, Lan; Li, Liming; Guan, Jian; Zang, Xuefeng; Zhen, Jie; Sheng, Bo; Zhu, Xi

    2017-04-01

    This study aimed to apply the dead space fraction [ratio of dead space to tidal volume (VD/VT)] to titrate the optimal positive end-expiratory pressure (PEEP) in a swine model of acute respiratory distress syndrome (ARDS). Twelve swine models of ARDS were constructed. A lung recruitment maneuver was then conducted and the PEEP was set at 20 cm H 2 O. The PEEP was reduced by 2 cm H 2 O every 10 min until 0 cm H 2 O was reached, and VD/VT was measured after each decrement step. VD/VT was measured using single-breath analysis of CO 2 , and calculated from arterial CO 2 partial pressure (PaCO 2 ) and mixed expired CO 2 (PeCO 2 ) using the following formula: VD/VT = (PaCO 2 - PeCO 2 )/PaCO 2 . The optimal PEEP was identified by the lowest VD/VT method. Respiration and hemodynamic parameters were recorded during the periods of pre-injury and injury, and at 4 and 2 cm H 2 O below and above the optimal PEEP (Po). The optimal PEEP in this study was found to be 13.25±1.36 cm H 2 O. During the Po period, VD/VT decreased to a lower value (0.44±0.08) compared with that during the injury period (0.68±0.10) (P<0.05), while the intrapulmonary shunt fraction reached its lowest value. In addition, a significant change of dynamic tidal respiratory compliance and oxygenation index was induced by PEEP titration. These results indicate that minimal VD/VT can be used for PEEP titration in ARDS.

  7. Mechanical ventilation with lower tidal volumes and positive end-expiratory pressure prevents pulmonary inflammation in patients without preexisting lung injury.

    Science.gov (United States)

    Wolthuis, Esther K; Choi, Goda; Dessing, Mark C; Bresser, Paul; Lutter, Rene; Dzoljic, Misa; van der Poll, Tom; Vroom, Margreeth B; Hollmann, Markus; Schultz, Marcus J

    2008-01-01

    Mechanical ventilation with high tidal volumes aggravates lung injury in patients with acute lung injury or acute respiratory distress syndrome. The authors sought to determine the effects of short-term mechanical ventilation on local inflammatory responses in patients without preexisting lung injury. Patients scheduled to undergo an elective surgical procedure (lasting > or = 5 h) were randomly assigned to mechanical ventilation with either higher tidal volumes of 12 ml/kg ideal body weight and no positive end-expiratory pressure (PEEP) or lower tidal volumes of 6 ml/kg and 10 cm H2O PEEP. After induction of anesthesia and 5 h thereafter, bronchoalveolar lavage fluid and/or blood was investigated for polymorphonuclear cell influx, changes in levels of inflammatory markers, and nucleosomes. Mechanical ventilation with lower tidal volumes and PEEP (n = 21) attenuated the increase of pulmonary levels of interleukin (IL)-8, myeloperoxidase, and elastase as seen with higher tidal volumes and no PEEP (n = 19). Only for myeloperoxidase, a difference was found between the two ventilation strategies after 5 h of mechanical ventilation (P volumes and PEEP may limit pulmonary inflammation in mechanically ventilated patients without preexisting lung injury. The specific contribution of both lower tidal volumes and PEEP on the protective effects of the lung should be further investigated.

  8. Clinical assessment of auto-positive end-expiratory pressure by diaphragmatic electrical activity during pressure support and neurally adjusted ventilatory assist.

    Science.gov (United States)

    Bellani, Giacomo; Coppadoro, Andrea; Patroniti, Nicolò; Turella, Marta; Arrigoni Marocco, Stefano; Grasselli, Giacomo; Mauri, Tommaso; Pesenti, Antonio

    2014-09-01

    Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and whether NAVA was beneficial in comparison with pressure support ventilation in patients affected by auto-PEEP. In 10 patients with a clinical suspicion of auto-PEEP, the authors simultaneously recorded EAdi, airway, esophageal pressure, and flow during pressure support and NAVA, whereas external PEEP was increased from 2 to 14 cm H2O. Tracings were analyzed to measure apparent "dynamic" auto-PEEP (decrease in esophageal pressure to generate inspiratory flow), auto-EAdi (EAdi value at the onset of inspiratory flow), and IDEAdi (inspiratory delay between the onset of EAdi and the inspiratory flow). The pressure necessary to overcome auto-PEEP, auto-EAdi, and IDEAdi was significantly lower in NAVA as compared with pressure support ventilation, decreased with increase in external PEEP, although the effect of external PEEP was less pronounced in NAVA. Both auto-EAdi and IDEAdi were tightly correlated with auto-PEEP (r = 0.94 and r = 0.75, respectively). In the presence of auto-PEEP at lower external PEEP levels, NAVA was characterized by a characteristic shape of the airway pressure. In patients with auto-PEEP, NAVA, compared with pressure support ventilation, led to a decrease in the pressure necessary to overcome auto-PEEP, which could be reliably monitored by the electrical activity of the diaphragm before inspiratory flow onset (auto-EAdi).

  9. Effects of respiratory rate, plateau pressure, and positive end-expiratory pressure on PaO2 oscillations after saline lavage.

    Science.gov (United States)

    Baumgardner, James E; Markstaller, Klaus; Pfeiffer, Birgit; Doebrich, Marcus; Otto, Cynthia M

    2002-12-15

    One of the proposed mechanisms of ventilator-associated lung injury is cyclic recruitment of atelectasis. Collapse of dependent lung regions with every breath should lead to large oscillations in PaO2 as shunt varies throughout the respiratory cycle. We placed a fluorescence-quenching PO2 probe in the brachiocephalic artery of six anesthetized rabbits after saline lavage. Using pressure-controlled ventilation with oxygen, ventilator settings were varied in random order over three levels of positive end-expiratory pressure (PEEP), respiratory rate (RR), and plateau pressure minus PEEP (Delta). Dependence of the amplitude of PaO2 oscillations on PEEP, RR, and Delta was modeled by multiple linear regression. Before lavage, arterial PO2 oscillations varied from 3 to 22 mm Hg. After lavage, arterial PO2 oscillations varied from 5 to 439 mm Hg. Response surfaces showed markedly nonlinear dependence of amplitude on PEEP, RR, and Delta. The large PaO2 oscillations observed provide evidence for cyclic recruitment in this model of lung injury. The important effect of RR on the magnitude of PaO2 oscillations suggests that the static behavior of atelectasis cannot be accurately extrapolated to predict dynamic behavior at realistic breathing frequencies.

  10. OPTIMUM LEVEL OF POSITIVE END-EXPIRATORY PRESSURE IN ACUTE RESPIRATORY DISTRESS SYNDROME CAUSED BY INFLUENZA A(H1NI)PDM09: BALANCE BETWEEN MAXIMAL END-EXPIRATORY VOLUME AND MINIMAL ALVEOLAR OVERDISTENSION.

    Science.gov (United States)

    Yaroshetskiym A I; Protsenko, D N; Boytsov, P V; Chentsov, V B; Nistratov, S L; Kudlyakov, O N; Solov'ev, V V; Banova, Zh I; Shkuratova, N V; Rezenov, N A; Gel'fand, B R

    2016-11-01

    to determine optimum level ofpositive end-expiratory pressure (PEEP) according to balance between maxi- mal end-expiratory lung volume (EEL V)(more than predicted) and minimal decrease in exhaled carbon dioxide volume (VCO) and then to develop the algorithm of gas exchange correction based on prognostic values of EEL K; alveolar recruitability, PA/FiO2, static compliance (C,,,) and VCO2. 27 mechanically ventilatedpatients with acute respiratory distress syndrome (ARDS) caused by influenza A (HINJ)pdm09 in Moscow Municipal Clinics ICU's from January to March 2016 were included in the trial. At the beginning of the study patients had the following characteristic: duration offlu symptoms 5 (3-10) days, p.0/FiO2 120 (70-50) mmHg. SOFA 7 (5-9), body mass index 30.1 (26.4-33.8) kg/m², static compliance of respiratory system 35 (30-40) ml/mbar: Under sedation and paralysis we measured EELV, C VCO and end-tidal carbon dioxide concentration (EtCO) (for CO₂ measurements we fixed short-term values after 2 min after PEEP level change) at PEEP 8, 11,13,15,18, 20 mbar consequently, and incase of good recruitability, at 22 and 24 mbar. After analyses of obtained data we determined PEEP value in which increase in EELV was maximal (more than predicted) and depression of VCO₂ was less than 20%, change in mean blood pressure and heart rate were both less than 20% (measured at PEEP 8 mbar). After that we set thus determined level of PEEP and didn't change it for 5 days. Comparision of predicted and measured EELV revealed two typical points of alveloar recruiment: the first at PEEP 11-15 mbar, the second at PEEP 20-22 mbar. EELV measured at PEEP 18 mbar appeared to be higher than predicted at PEEP 8 mbar by 400 ml (approx.), which was the sign of alveolar recruitment-1536 (1020-1845) ml vs 1955 (1360-2320) ml, p=0,001, Friedman test). we didn't found significant changes of VCO₂ when increased PEEP in the range from 8 to 15 mbar (p>0.05, Friedman test). PEEP increase from 15 to

  11. Pulmonary lesion induced by low and high positive end-expiratory pressure levels during protective ventilation in experimental acute lung injury.

    Science.gov (United States)

    Pássaro, Caroline P; Silva, Pedro L; Rzezinski, Andréia F; Abrantes, Simone; Santiago, Viviane R; Nardelli, Liliane; Santos, Raquel S; Barbosa, Carolina M L; Morales, Marcelo M; Zin, Walter A; Amato, Marcelo B P; Capelozzi, Vera L; Pelosi, Paolo; Rocco, Patricia R M

    2009-03-01

    To investigate the effects of low and high levels of positive end-expiratory pressure (PEEP), without recruitment maneuvers, during lung protective ventilation in an experimental model of acute lung injury (ALI). Prospective, randomized, and controlled experimental study. University research laboratory. Wistar rats were randomly assigned to control (C) [saline (0.1 mL), intraperitoneally] and ALI [paraquat (15 mg/kg), intraperitoneally] groups. After 24 hours, each group was further randomized into four groups (six rats each) at different PEEP levels = 1.5, 3, 4.5, or 6 cm H2O and ventilated with a constant tidal volume (6 mL/kg) and open thorax. Lung mechanics [static elastance (Est, L) and viscoelastic pressure (DeltaP2, L)] and arterial blood gases were measured before (Pre) and at the end of 1-hour mechanical ventilation (Post). Pulmonary histology (light and electron microscopy) and type III procollagen (PCIII) messenger RNA (mRNA) expression were measured after 1 hour of mechanical ventilation. In ALI group, low and high PEEP levels induced a greater percentage of increase in Est, L (44% and 50%) and DeltaP2, L (56% and 36%) in Post values related to Pre. Low PEEP yielded alveolar collapse whereas high PEEP caused overdistension and atelectasis, with both levels worsening oxygenation and increasing PCIII mRNA expression. In the present nonrecruited ALI model, protective mechanical ventilation with lower and higher PEEP levels than required for better oxygenation increased Est, L and DeltaP2, L, the amount of atelectasis, and PCIII mRNA expression. PEEP selection titrated for a minimum elastance and maximum oxygenation may prevent lung injury while deviation from these settings may be harmful.

  12. The Neopuff's PEEP valve is flow sensitive.

    LENUS (Irish Health Repository)

    Hawkes, Colin Patrick

    2011-03-01

    The current recommendation in setting up the Neopuff is to use a gas flow of 5-15 L\\/min. We investigated if the sensitivity of the positive end expiratory pressure (PEEP) valve varies at different flow rates within this range.

  13. Effects of positive end-expiratory pressure titration and recruitment maneuver on lung inflammation and hyperinflation in experimental acid aspiration-induced lung injury.

    Science.gov (United States)

    Ambrosio, Aline M; Luo, Rubin; Fantoni, Denise T; Gutierres, Claudia; Lu, Qin; Gu, Wen-Jie; Otsuki, Denise A; Malbouisson, Luiz M S; Auler, Jose O C; Rouby, Jean-Jacques

    2012-12-01

    In acute lung injury positive end-expiratory pressure (PEEP) and recruitment maneuver are proposed to optimize arterial oxygenation. The aim of the study was to evaluate the impact of such a strategy on lung histological inflammation and hyperinflation in pigs with acid aspiration-induced lung injury. Forty-seven pigs were randomly allocated in seven groups: (1) controls spontaneously breathing; (2) without lung injury, PEEP 5 cm H2O; (3) without lung injury, PEEP titration; (4) without lung injury, PEEP titration + recruitment maneuver; (5) with lung injury, PEEP 5 cm H2O; (6) with lung injury, PEEP titration; and (7) with lung injury, PEEP titration + recruitment maneuver. Acute lung injury was induced by intratracheal instillation of hydrochloric acid. PEEP titration was performed by incremental and decremental PEEP from 5 to 20 cm H2O for optimizing arterial oxygenation. Three recruitment maneuvers (pressure of 40 cm H2O maintained for 20 s) were applied to the assigned groups at each PEEP level. Proportion of lung inflammation, hemorrhage, edema, and alveolar wall disruption were recorded on each histological field. Mean alveolar area was measured in the aerated lung regions. Acid aspiration increased mean alveolar area and produced alveolar wall disruption, lung edema, alveolar hemorrhage, and lung inflammation. PEEP titration significantly improved arterial oxygenation but simultaneously increased lung inflammation in juxta-diaphragmatic lung regions. Recruitment maneuver during PEEP titration did not induce additional increase in lung inflammation and alveolar hyperinflation. In a porcine model of acid aspiration-induced lung injury, PEEP titration aimed at optimizing arterial oxygenation, substantially increased lung inflammation. Recruitment maneuvers further improved arterial oxygenation without additional effects on inflammation and hyperinflation.

  14. Effects of positive end expiratory pressure administration during non-invasive ventilation in patients affected by amyotrophic lateral sclerosis: A randomized crossover study.

    Science.gov (United States)

    Crescimanno, Grazia; Greco, Francesca; Arrisicato, Salvo; Morana, Noemi; Marrone, Oreste

    2016-10-01

    No studies have evaluated the impact of different settings of non-invasive ventilation (NIV) in patients affected by amyotrophic lateral sclerosis (ALS). We explored consequences of positive end-expiratory pressure (PEEP) application on effectiveness of ventilation, sleep architecture and heart rate variability (HRV) in patients with ALS naïve to ventilatory treatment. In two consecutive nights, 25 patients received in random order 0 or 4 cm H2 0 of PEEP during nocturnal NIV administration (Idea Ultra ResMed) with the same level of total positive inspiratory pressure. Polysomnographies were performed to evaluate sleep and NIV quality, as well as HRV. HRV was analyzed on 4-h periods and on 5-min segments of stable NREM sleep. We did not observe differences in gas exchanges during NIV with and without PEEP. Conversely, during PEEP application increases in leaks (41.4 ± 29.3% vs 31.0 ± 25.7%, P = 0.0007) and in autotriggerings (4.2 (IQR 1.3-10.0) vs 0.9 (IQR 0.0-3.0) events/h, P NIV was associated with worse NIV and sleep quality and with higher sympathetic activity. © 2016 Asian Pacific Society of Respirology.

  15. [Clinical research of using optimal compliance to determine positive end-expiratory pressure].

    Science.gov (United States)

    Xu, Lei; Feng, Quan-sheng; Lian, Fu; Shao, Xin-hua; Li, Zhi-bo; Wang, Zhi-yong; Li, Jun

    2012-07-01

    To observe the availability and security of optimal compliance strategy to titrate the optimal positive end-expiratory pressure (PEEP), compared with quasi-static pressure-volume curve (P-V curve) traced by low-flow method. Fourteen patients received mechanical ventilation with acute respiratory distress syndrome (ARDS) admitted in intensive care unit (ICU) of Tianjin Third Central Hospital from November 2009 to December 2010 were divided into two groups(n = 7). The quasi-static P-V curve method and the optimal compliance titration were used to set the optimal PEEP respectively, repeated 3 times in a row. The optimal PEEP and the consistency of repeated experiments were compared between groups. The hemodynamic parameters, oxygenation index (OI), lung compliance (C), cytokines and pulmonary surfactant-associated protein D (SP-D) concentration in plasma before and 2, 4, and 6 hours after the experiment were observed in each group. (1) There were no significant differences in gender, age and severity of disease between two groups. (2)The optimal PEEP [cm H(2)O, 1 cm H(2)O=0.098 kPa] had no significant difference between quasi-static P-V curve method group and the optimal compliance titration group (11.53 ± 2.07 vs. 10.57 ± 0.87, P>0.05). The consistency of repeated experiments in quasi-static P-V curve method group was poor, the slope of the quasi-static P-V curve in repeated experiments showed downward tendency. The optimal PEEP was increasing in each measure. There was significant difference between the first and the third time (10.00 ± 1.58 vs. 12.80 ± 1.92, P vs. 93.71 ± 5.38, temperature: 38.05 ± 0.73 vs. 36.99 ± 1.02, IL-6: 144.84 ± 23.89 vs. 94.73 ± 5.91, TNF-α: 151.46 ± 46.00 vs. 89.86 ± 13.13, SP-D: 33.65 ± 8.66 vs. 16.63 ± 5.61, MAP: 85.47 ± 9.24 vs. 102.43 ± 8.38, CCI: 3.00 ± 0.48 vs. 3.81 ± 0.81, OI: 62.00 ± 21.45 vs. 103.40 ± 37.27, C: 32.10 ± 2.92 vs. 49.57 ± 7.18, all P safety and usability.

  16. Respiratory effects of low versus high tidal volume with or without positive end-expiratory pressure in anesthetized dogs with healthy lungs.

    Science.gov (United States)

    De Monte, Valentina; Bufalari, Antonello; Grasso, Salvatore; Ferrulli, Fabienne; Crovace, Alberto Maria; Lacitignola, Luca; Staffieri, Francesco

    2018-05-01

    OBJECTIVE To evaluate the impact of 2 tidal volumes (T V s) with or without positive end-expiratory pressure (PEEP) on lung mechanics, aeration, and gas exchange in healthy anesthetized dogs. ANIMALS 40 mixed-breed dogs with healthy lungs. PROCEDURES Anesthetized dogs were randomly assigned to 4 groups (n = 10/group) with different ventilatory settings: T V of 8 mL/kg and PEEP of 0 cm H 2 O (low T V group), T V of 8 mL/kg and PEEP of 5 cm H 2 O (low T V plus PEEP group), T V of 15 mL/kg and PEEP of 0 cm H 2 O (high T V group), or T V of 15 mL/kg and PEEP of 5 cm H 2 O (high T V plus PEEP group). Expired CO 2 and respiratory rate were titrated on the basis of a predetermined stepwise protocol. Gas exchange, respiratory mechanics, and pulmonary aeration were evaluated by means of CT 30 minutes after starting mechanical ventilation at the assigned setting. RESULTS Partial pressures of arterial and expired CO 2 were higher in the low T V and low T V plus PEEP groups than in the high T V and high T V plus PEEP groups. Peak and plateau airway pressures were higher in the PEEP group than in the other groups. Static lung compliance was higher in the high T V plus PEEP group than in the low T V group. Relative percentages of atelectatic and poorly aerated lung were lower in the high T V plus PEEP group than in the other groups. Oxygenation was similar among groups. CONCLUSIONS AND CLINICAL RELEVANCE Differences in T V and PEEP application during mechanical ventilation may affect respiratory function in anesthetized dogs with healthy lungs. Ventilation with a T V of 15 mL/kg and PEEP of 5 cm H 2 O significantly improved lung compliance and reduced the amount of atelectatic and poorly aerated lung.

  17. Combined Effects of Ventilation Mode and Positive End-Expiratory Pressure on Mechanics, Gas Exchange and the Epithelium in Mice with Acute Lung Injury

    Science.gov (United States)

    Thammanomai, Apiradee; Hamakawa, Hiroshi; Bartolák-Suki, Erzsébet; Suki, Béla

    2013-01-01

    The accepted protocol to ventilate patients with acute lung injury is to use low tidal volume (VT) in combination with recruitment maneuvers or positive end-expiratory pressure (PEEP). However, an important aspect of mechanical ventilation has not been considered: the combined effects of PEEP and ventilation modes on the integrity of the epithelium. Additionally, it is implicitly assumed that the best PEEP-VT combination also protects the epithelium. We aimed to investigate the effects of ventilation mode and PEEP on respiratory mechanics, peak airway pressures and gas exchange as well as on lung surfactant and epithelial cell integrity in mice with acute lung injury. HCl-injured mice were ventilated at PEEPs of 3 and 6 cmH2O with conventional ventilation (CV), CV with intermittent large breaths (CVLB) to promote recruitment, and a new mode, variable ventilation, optimized for mice (VVN). Mechanics and gas exchange were measured during ventilation and surfactant protein (SP)-B, proSP-B and E-cadherin levels were determined from lavage and lung homogenate. PEEP had a significant effect on mechanics, gas exchange and the epithelium. The higher PEEP reduced lung collapse and improved mechanics and gas exchange but it also down regulated surfactant release and production and increased epithelial cell injury. While CVLB was better than CV, VVN outperformed CVLB in recruitment, reduced epithelial injury and, via a dynamic mechanotransduction, it also triggered increased release and production of surfactant. For long-term outcome, selection of optimal PEEP and ventilation mode may be based on balancing lung physiology with epithelial injury. PMID:23326543

  18. Lung-protective ventilation in intensive care unit and operation room : Tidal volume size, level of positive end-expiratory pressure and driving pressure

    NARCIS (Netherlands)

    Serpa Neto, A.

    2017-01-01

    Several investigations have shown independent associations between three ventilator settings – tidal volume size, positive end–expiratory pressure (PEEP) and driving pressure – and outcomes in patients with the acute respiratory distress syndrome (ARDS). There is an increasing notion that similar

  19. Automatic detection of AutoPEEP during controlled mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Nguyen Quang-Thang

    2012-06-01

    Full Text Available Abstract Background Dynamic hyperinflation, hereafter called AutoPEEP (auto-positive end expiratory pressure with some slight language abuse, is a frequent deleterious phenomenon in patients undergoing mechanical ventilation. Although not readily quantifiable, AutoPEEP can be recognized on the expiratory portion of the flow waveform. If expiratory flow does not return to zero before the next inspiration, AutoPEEP is present. This simple detection however requires the eye of an expert clinician at the patient’s bedside. An automatic detection of AutoPEEP should be helpful to optimize care. Methods In this paper, a platform for automatic detection of AutoPEEP based on the flow signal available on most of recent mechanical ventilators is introduced. The detection algorithms are developed on the basis of robust non-parametric hypothesis testings that require no prior information on the signal distribution. In particular, two detectors are proposed: one is based on SNT (Signal Norm Testing and the other is an extension of SNT in the sequential framework. The performance assessment was carried out on a respiratory system analog and ex-vivo on various retrospectively acquired patient curves. Results The experiment results have shown that the proposed algorithm provides relevant AutoPEEP detection on both simulated and real data. The analysis of clinical data has shown that the proposed detectors can be used to automatically detect AutoPEEP with an accuracy of 93% and a recall (sensitivity of 90%. Conclusions The proposed platform provides an automatic early detection of AutoPEEP. Such functionality can be integrated in the currently used mechanical ventilator for continuous monitoring of the patient-ventilator interface and, therefore, alleviate the clinician task.

  20. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  1. Protective intraoperative ventilation with higher versus lower levels of positive end-expiratory pressure in obese patients (PROBESE): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Bluth, T; Teichmann, R; Kiss, T; Bobek, I; Canet, J; Cinnella, G; De Baerdemaeker, L; Gregoretti, C; Hedenstierna, G; Hemmes, S N; Hiesmayr, M; Hollmann, M W; Jaber, S; Laffey, J G; Licker, M J; Markstaller, K; Matot, I; Müller, G; Mills, G H; Mulier, J P; Putensen, C; Rossaint, R; Schmitt, J; Senturk, M; Serpa Neto, A; Severgnini, P; Sprung, J; Vidal Melo, M F; Wrigge, H; Schultz, M J; Pelosi, P; Gama de Abreu, M

    2017-04-28

    Postoperative pulmonary complications (PPCs) increase the morbidity and mortality of surgery in obese patients. High levels of positive end-expiratory pressure (PEEP) with lung recruitment maneuvers may improve intraoperative respiratory function, but they can also compromise hemodynamics, and the effects on PPCs are uncertain. We hypothesized that intraoperative mechanical ventilation using high PEEP with periodic recruitment maneuvers, as compared with low PEEP without recruitment maneuvers, prevents PPCs in obese patients. The PRotective Ventilation with Higher versus Lower PEEP during General Anesthesia for Surgery in OBESE Patients (PROBESE) study is a multicenter, two-arm, international randomized controlled trial. In total, 2013 obese patients with body mass index ≥35 kg/m 2 scheduled for at least 2 h of surgery under general anesthesia and at intermediate to high risk for PPCs will be included. Patients are ventilated intraoperatively with a low tidal volume of 7 ml/kg (predicted body weight) and randomly assigned to PEEP of 12 cmH 2 O with lung recruitment maneuvers (high PEEP) or PEEP of 4 cmH 2 O without recruitment maneuvers (low PEEP). The occurrence of PPCs will be recorded as collapsed composite of single adverse pulmonary events and represents the primary endpoint. To our knowledge, the PROBESE trial is the first multicenter, international randomized controlled trial to compare the effects of two different levels of intraoperative PEEP during protective low tidal volume ventilation on PPCs in obese patients. The results of the PROBESE trial will support anesthesiologists in their decision to choose a certain PEEP level during general anesthesia for surgery in obese patients in an attempt to prevent PPCs. ClinicalTrials.gov identifier: NCT02148692. Registered on 23 May 2014; last updated 7 June 2016.

  2. Low tidal volume and high positive end-expiratory pressure mechanical ventilation results in increased inflammation and ventilator-associated lung injury in normal lungs.

    Science.gov (United States)

    Hong, Caron M; Xu, Da-Zhong; Lu, Qi; Cheng, Yunhui; Pisarenko, Vadim; Doucet, Danielle; Brown, Margaret; Aisner, Seena; Zhang, Chunxiang; Deitch, Edwin A; Delphin, Ellise

    2010-06-01

    Protective mechanical ventilation with low tidal volume (Vt) and low plateau pressure reduces mortality and decreases the length of mechanical ventilation in patients with acute respiratory distress syndrome. Mechanical ventilation that will protect normal lungs during major surgical procedures of long duration may improve postoperative outcomes. We performed an animal study comparing 3 ventilation strategies used in the operating room in normal lungs. We compared the effects on pulmonary mechanics, inflammatory mediators, and lung tissue injury. Female pigs were randomized into 3 groups. Group H-Vt/3 (n = 6) was ventilated with a Vt of 15 mL/kg predicted body weight (PBW)/positive end-expiratory pressure (PEEP) of 3 cm H(2)O, group L-Vt/3 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 3 cm H(2)O, and group L-Vt/10 (n = 6) with a Vt of 6 mL/kg PBW/PEEP of 10 cm H(2)O, for 8 hours. Hemodynamics, airway mechanics, arterial blood gases, and inflammatory markers were monitored. Bronchoalveolar lavage (BAL) was analyzed for inflammatory markers and protein concentration. The right lower lobe was assayed for mRNA of specific cytokines. The right lower lobe and right upper lobe were evaluated histologically. In contrast to groups H-Vt/3 and L-Vt/3, group L-Vt/10 exhibited a 6-fold increase in inflammatory mediators in BAL (P ventilation with high PEEP resulted in increased production of inflammatory markers. Low PEEP resulted in lower levels of inflammatory markers. High Vt/low PEEP resulted in less histologic lung injury.

  3. Static end-expiratory and dynamic forced expiratory tracheal collapse in COPD

    International Nuclear Information System (INIS)

    O'Donnell, C.R.; Bankier, A.A.; O'Donnell, D.H.; Loring, S.H.; Boiselle, P.M.

    2014-01-01

    Aim: To determine the range of tracheal collapse at end-expiration among chronic obstructive pulmonary disease (COPD) patients and to compare the extent of tracheal collapse between static end-expiratory and dynamic forced-expiratory multidetector-row computed tomography (MDCT). Materials and methods: After institutional review board approval and obtaining informed consent, 67 patients meeting the National Heart, Lung, and Blood Institute (NHLBI)/World Health Organization (WHO) Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria for COPD were sequentially imaged using a 64-detector-row CT machine at end-inspiration, during forced expiration, and at end-expiration. Standardized respiratory coaching and spirometric monitoring were employed. Mean percentage tracheal collapse at end-expiration and forced expiration were compared using correlation analysis, and the power of end-expiratory cross-sectional area to predict excessive forced-expiratory tracheal collapse was computed following construction of receiver operating characteristic (ROC) curves. Results: Mean percentage expiratory collapse among COPD patients was 17 ± 18% at end-expiration compared to 62 ± 16% during forced expiration. Over the observed range of end-expiratory tracheal collapse (approximately 10–50%), the positive predictive value of end-expiratory collapse to predict excessive (≥80%) forced expiratory tracheal collapse was <0.3. Conclusion: COPD patients demonstrate a wide range of end-expiratory tracheal collapse. The magnitude of static end-expiratory tracheal collapse does not predict excessive dynamic expiratory tracheal collapse

  4. Cardiorespiratory effects of balancing PEEP with intra-abdominal pressures during laparoscopic cholecystectomy.

    Science.gov (United States)

    Kundra, Pankaj; Subramani, Yamini; Ravishankar, M; Sistla, Sarath C; Nagappa, Mahesh; Sivashanmugam, T

    2014-06-01

    Applying appropriate positive end-expiratory pressure (PEEP) to corresponding intra-abdominal pressure (IAP) can improve gas exchange during capnoperitoneum without any hemodynamic effects. A total of 75 patients were randomly allocated to group 0PEEP (n=25), group 5PEEP (n=25), and group 10PEEP (n=25) according to the level of PEEP, in whom capnoperitoneum was created with IAP of 14, 8, and 14 mm Hg, respectively. Hemodynamic and respiratory parameters were recorded up to 30 minutes after capnoperitoneum. In 0PEEP group, mean end-tidal carbon dioxide demonstrated significant rise 2 minutes after capnoperitoneum and plateaued at about 15 minutes but remained at high level for up to 30 minutes when compared with the 5PEEP and 10PEEP groups (Phigher at 30 minutes when compared with 5PEEP (37.8±2.7 mm Hg) and 10PEEP (37.2±3.9 mm Hg) groups. The oxygenation was better preserved in 5PEEP and 10PEEP groups with significantly higher PaO2/Fio2 ratio. Heart rate, mean arterial pressure, and cardiac output remained stable throughout the study in all the 3 groups. Application of appropriate PEEP corresponding to the IAP helped maintain CO2 elimination and improved oxygenation without any hemodynamic disturbance in patients undergoing laparoscopic cholecystectomy.

  5. [A comparative study between inflation and deflation pressure-volume curve in determining the optimal positive end-expiratory pressure].

    Science.gov (United States)

    Gang, Li; Sun, Xiao-yi; Xu, Jin-quan; Zhang, Xin-li; Kou, Lu-xin; Jiang, Zhi-hong; Zhang, Lei

    2012-02-01

    To determine the optimal positive end-expiratory pressure (PEEP) according to inflation and deflation pressure-volume curve (P-V curve) in patients with acute respiratory distress syndrome (ARDS). ARDS models were reproduced in 20 dogs, and they were randomly divided into two groups. In both groups, Levenberg-Marquardt iterative algorithm was employed using software to explore parameters fitting with Boltzmann formula, by which the real inflection point of pressure (Pinf d) in deflation limb or lower inflection point pressure (PLip) in inflation limb on P-V curve were defined. For the control group (inflation curve) P-V curve of PLip + 2 cm H(2)O [1 cm H(2)O = 0.098 kPa] was applied as the best PEEP value. In the experimental group (deflation curve) the Pinf d was taken as the best PEEP value. The heart rate (HR), blood pressure (BP), fingertip pulse oxygen saturation [SpO(2)], static lung compliance (Cst), arterial partial pressure of oxygen [PaO(2)] and arterial partial pressure of carbon dioxide [PaCO(2)] were monitored at 0, 2, 6, 12, 24 and 48 hours. Oxygenation index increased significantly both in control and experimental groups. In experimental group, oxygenation index (mm Hg, 1 mm Hg = 0.133 kPa) of 12, 24 and 48 hours was respectively significantly higher than that of the control group (12 hours: 177.63 ± 8.94 vs. 165.60 ± 8.90, 24 hours: 194.19 ± 10.67 vs. 168.70 ± 10.60, 48 hours: 203.15 ± 13.21 vs. 171.26 ± 9.21, all P deflation P-V curve was better than that of inflation curve.

  6. Double-lumen tubes and auto-PEEP during one-lung ventilation.

    Science.gov (United States)

    Spaeth, J; Ott, M; Karzai, W; Grimm, A; Wirth, S; Schumann, S; Loop, T

    2016-01-01

    Double-lumen tubes (DLT) are routinely used to enable one-lung-ventilation (OLV) during thoracic anaesthesia. The flow-dependent resistance of the DLT's bronchial limb may be high as a result of its narrow inner diameter and length, and thus potentially contribute to an unintended increase in positive end-expiratory pressure (auto-PEEP). We therefore studied the impact of adult sized DLTs on the dynamic auto-PEEP during OLV. In this prospective clinical study, dynamic auto-PEEP was determined in 72 patients undergoing thoracic surgery, with right- and left-sided DLTs of various sizes. During OLV, air trapping was provoked by increasing inspiration to expiration ratio from 1:2 to 2:1 (five steps). Based on measured flow rate, airway pressure (Paw) and bronchial pressure (Pbronch), the pressure gradient across the DLT (ΔPDLT) and the total auto-PEEP in the respiratory system (i.e. the lungs, the DLT and the ventilator circuit) were determined. Subsequently the DLT's share in total auto-PEEP was calculated. ΔPDLT was 2.3 (0.7) cm H2O over the entire breathing cycle. At the shortest expiratory time the mean total auto-PEEP was 2.9 (1.5) cm H2O (range 0-5.9 cm H2O). The DLT caused 27 to 31% of the total auto-PEEP. Size and side of the DLT's bronchial limb did not impact auto-PEEP significantly. Although the DLT contributes to the overall auto-PEEP, its contribution is small and independent of size and side of the DLT's bronchial limb. The choice of DLT does not influence the risk of auto-PEEP during OLV to a clinically relevant extent. DRKS00005648. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. The Neopuff's PEEP valve is flow sensitive.

    LENUS (Irish Health Repository)

    Hawkes, Colin Patrick

    2012-01-31

    AIM: The current recommendation in setting up the Neopuff is to use a gas flow of 5-15 L\\/min. We investigated if the sensitivity of the positive end expiratory pressure (PEEP) valve varies at different flow rates within this range. METHODS: Five Neopuffs were set up to provide a PEEP of 5 cm H(2) O. The number of clockwise revolutions to complete occlusion of the PEEP valve and the mean and range of pressures at each quarter clockwise revolution were recorded at gas flow rates between 5 and 15 L\\/min. Results: At 5, 10 and 15 L\\/min, 0.5, 1.7 and 3.4 full clockwise rotations were required to completely occlude the PEEP valve, and pressures rose from 5 to 11.4, 18.4 and 21.5 cm H(2) O, respectively. At a flow rate of 5 L\\/min, half a rotation of the PEEP dial resulted in a rise in PEEP from 5 to 11.4cm H(2) O. At 10 L\\/min, half a rotation resulted in a rise from 5 to 7.7cm H(2) O, and at 15 L\\/min PEEP rose from 5 to 6.8cm H(2) O. CONCLUSION: Users of the Neopuff should be aware that the PEEP valve is more sensitive at lower flow rates and that half a rotation of the dial at 5 L\\/min gas flow can more than double the PEEP.

  8. "THE EVALUATION OF THE POSSIBLE EFFECT OF POSITIVE END EXPIRATORY PRESSURE (PEEP ON PHARMACOKINETICS OF PHENYTOIN IN PATIENTS WITH ACUTE BRAIN INJURY UNDER MECHANICAL VENTILATION."

    Directory of Open Access Journals (Sweden)

    "Elham Hadidi

    2005-04-01

    Full Text Available Positive ventilation has shown to have an influence on pharmacokinetic and disposition of some drugs.Beacause phenytoin with a narrow therapautic range, is the most commonly used drug for prophylaxis and treatment of early seizures after acute brain injuries, in the present study the effect of short term PEEP (5-10 cm H2O for at least 8 hours on phenytoin serum concentration and pharmacokinetic parameters such as Vmax and clearance in brain injured patients under mechanical ventilation was examined. Ten patients with moderate to severe acute brain injury who were placed on mechanical ventilation with an initial PEEP level of 0-5 cm H2O were included in the study. Patients received phenytoin loading dose of 15 mg/kg followed by a maintenance daily dose of 3-7 mg/kg initiated within 12 hours of loading dose. Sampels were taken on two different occasions before and after PEEP elevation. Total phenytoin serum concentrations were determined by HPLC method. A time invarient Michaelis-Menten pharmacokinetic model was used to calculate Vmax and clearance for each patient.Derrived variables were calculated as follows: Vmax, 3.5-6.8 and 3.7-8.2 mg/kg/day; Clearance, 0.1-0.7 and 0.1-1.2 l/kg/day (before and after PEEP elevation, respectively. Our data have shown a wide range of variability (2.6-32.5 mg/l in phenytoin serum concentrations. There were no statistically significant differences in the measured total concentrations (p=0.721 and calculated Vmax and clearance (p=0.285before and after PEEP elevation. Administration of fluid and inotropic agents, limitation in application of higher levels of PEEP and drug interactions, shall be considered as possible explanations for these findings.

  9. Hyperinflation and intrinsic positive end-expiratory pressure: less room to breathe.

    Science.gov (United States)

    Krieger, Bruce P

    2009-01-01

    Clinically, the symptoms and limited exercise capabilities of patients with chronic obstructive pulmonary disease (COPD) correlate better with changes in lung volumes than with airflow measurements. The realization of the clinical importance of hyperinflation has been overshadowed for decades by the use of forced expiratory volume during 1 s (FEV(1)) and the ratio of the FEV(1) to the forced expiratory vital capacity (FEV(1)/FVC) to categorize the severity and progression of COPD. Hyperinflation is defined as an elevation in the end-expiratory lung volume or functional residual capacity. When severe hyperinflation encroaches upon inspiratory capacity and limits vital capacity, it results in elevated intrinsic positive end-expiratory pressure (PEEPi) that places the diaphragm at a mechanical disadvantage and increases the work of breathing. Severe hyperinflation is the major physiologic cause of the resulting hypercarbic respiratory failure and patients' inability to transition (i.e. wean) from mechanical ventilatory support to spontaneous breathing. This paper reviews the basic physiologic principles of hyperinflation and its clinical manifestations as demonstrated by PEEPi. Also reviewed are the adverse effects of hyperinflation and PEEPi in critically ill patients with COPD, and methods for minimizing or counterbalancing these effects. Copyright 2009 S. Karger AG, Basel.

  10. Effect of patient position and PEEP on hepatic, portal and central venous pressures during liver resection.

    Science.gov (United States)

    Sand, L; Rizell, M; Houltz, E; Karlsen, K; Wiklund, J; Odenstedt Hergès, H; Stenqvist, O; Lundin, S

    2011-10-01

    It has been suggested that blood loss during liver resection may be reduced if central venous pressure (CVP) is kept at a low level. This can be achieved by changing patient position but it is not known how position changes affect portal (PVP) and hepatic (HVP) venous pressures. The aim of the study was to assess if changes in body position result in clinically significant changes in these pressures. We studied 10 patients undergoing liver resection. Mean arterial pressure (MAP) and CVP were measured using fluid-filled catheters, PVP and HVP with tip manometers. Measurements were performed in the horizontal, head up and head down tilt position with two positive end expiratory pressure (PEEP) levels. A 10° head down tilt at PEEP 5 cm H(2) O significantly increased CVP (11 ± 3 to 15 ± 3 mmHg) and MAP (72 ± 8 to 76 ± 8 mmHg) while head up tilt at PEEP 5 cm H(2) O decreased CVP (11 ± 3 to 6 ± 4 mmHg) and MAP (72 ± 8 to 63 ± 7 mmHg) with minimal changes in transhepatic venous pressures. Increasing PEEP from 5 to 10 resulted in small increases, around 1 mmHg in CVP, PVP and HVP. There was no significant correlation between changes in CVP vs. PVP and HVP during head up tilt and only a weak correlation between CVP and HVP by head down tilt. Changes of body position resulted in marked changes in CVP but not in HVPs. Head down or head up tilt to reduce venous pressures in the liver may therefore not be effective measures to reduce blood loss during liver surgery. 2011 The Authors Acta Anaesthesiologica Scandinavica, 2011 The Acta Anaesthesiologica Scandinavica Foundation.

  11. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.

    Science.gov (United States)

    Berger, David; Moller, Per W; Weber, Alberto; Bloch, Andreas; Bloechlinger, Stefan; Haenggi, Matthias; Sondergaard, Soren; Jakob, Stephan M; Magder, Sheldon; Takala, Jukka

    2016-09-01

    According to Guyton's model of circulation, mean systemic filling pressure (MSFP), right atrial pressure (RAP), and resistance to venous return (RVR) determine venous return. MSFP has been estimated from inspiratory hold-induced changes in RAP and blood flow. We studied the effect of positive end-expiratory pressure (PEEP) and blood volume on venous return and MSFP in pigs. MSFP was measured by balloon occlusion of the right atrium (MSFPRAO), and the MSFP obtained via extrapolation of pressure-flow relationships with airway occlusion (MSFPinsp_hold) was extrapolated from RAP/pulmonary artery flow (QPA) relationships during inspiratory holds at PEEP 5 and 10 cmH2O, after bleeding, and in hypervolemia. MSFPRAO increased with PEEP [PEEP 5, 12.9 (SD 2.5) mmHg; PEEP 10, 14.0 (SD 2.6) mmHg, P = 0.002] without change in QPA [2.75 (SD 0.43) vs. 2.56 (SD 0.45) l/min, P = 0.094]. MSFPRAO decreased after bleeding and increased in hypervolemia [10.8 (SD 2.2) and 16.4 (SD 3.0) mmHg, respectively, P waterfall. Copyright © 2016 the American Physiological Society.

  12. PEEP-ZEEP technique: cardiorespiratory repercussions in mechanically ventilated patients submitted to a coronary artery bypass graft surgery

    Directory of Open Access Journals (Sweden)

    Auler José

    2011-09-01

    Full Text Available Abstract Background The PEEP-ZEEP technique is previously described as a lung inflation through a positive pressure enhancement at the end of expiration (PEEP, followed by rapid lung deflation with an abrupt reduction in the PEEP to 0 cmH2O (ZEEP, associated to a manual bilateral thoracic compression. Aim To analyze PEEP-ZEEP technique's repercussions on the cardio-respiratory system in immediate postoperative artery graft bypass patients. Methods 15 patients submitted to a coronary artery bypass graft surgery (CABG were enrolled prospectively, before, 10 minutes and 30 minutes after the technique. Patients were curarized, intubated, and mechanically ventilated. To perform PEEP-ZEEP technique, saline solution was instilled into their orotracheal tube than the patient was reconnected to the ventilator. Afterwards, the PEEP was increased to 15 cmH2O throughout 5 ventilatory cycles and than the PEEP was rapidly reduced to 0 cmH2O along with manual bilateral thoracic compression. At the end of the procedure, tracheal suction was accomplished. Results The inspiratory peak and plateau pressures increased during the procedure (p Conclusion The PEEP-ZEEP technique seems to be safe, without alterations on hemodynamic variables, produces elevated expiratory flow and seems to be an alternative technique for the removal of bronchial secretions in patients submitted to a CABG.

  13. Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model.

    Directory of Open Access Journals (Sweden)

    Laura A Cagle

    Full Text Available Positive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury.To evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation.5-12 week-old female BALB/c mice (n = 85 were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg or high tidal volume (15 ml/kg with or without positive end-expiratory pressure and recruitment maneuvers.Alteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation.Signs of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours and lung injury worsens with longer-term ventilation (4 hrs. Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points. Dynamic compliance can be used guide

  14. Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model

    Science.gov (United States)

    Franzi, Lisa M.; Linderholm, Angela L.; Last, Jerold A.; Adams, Jason Y.; Harper, Richart W.

    2017-01-01

    Background Positive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury. Objectives To evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation. Methods 5–12 week-old female BALB/c mice (n = 85) were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg) or high tidal volume (15 ml/kg) with or without positive end-expiratory pressure and recruitment maneuvers. Results Alteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation. Conclusions Signs of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours) and lung injury worsens with longer-term ventilation (4 hrs). Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points

  15. Effects of positive end-expiratory pressure and recruitment maneuvers in a ventilator-induced injury mouse model.

    Science.gov (United States)

    Cagle, Laura A; Franzi, Lisa M; Linderholm, Angela L; Last, Jerold A; Adams, Jason Y; Harper, Richart W; Kenyon, Nicholas J

    2017-01-01

    Positive-pressure mechanical ventilation is an essential therapeutic intervention, yet it causes the clinical syndrome known as ventilator-induced lung injury. Various lung protective mechanical ventilation strategies have attempted to reduce or prevent ventilator-induced lung injury but few modalities have proven effective. A model that isolates the contribution of mechanical ventilation on the development of acute lung injury is needed to better understand biologic mechanisms that lead to ventilator-induced lung injury. To evaluate the effects of positive end-expiratory pressure and recruitment maneuvers in reducing lung injury in a ventilator-induced lung injury murine model in short- and longer-term ventilation. 5-12 week-old female BALB/c mice (n = 85) were anesthetized, placed on mechanical ventilation for either 2 hrs or 4 hrs with either low tidal volume (8 ml/kg) or high tidal volume (15 ml/kg) with or without positive end-expiratory pressure and recruitment maneuvers. Alteration of the alveolar-capillary barrier was noted at 2 hrs of high tidal volume ventilation. Standardized histology scores, influx of bronchoalveolar lavage albumin, proinflammatory cytokines, and absolute neutrophils were significantly higher in the high-tidal volume ventilation group at 4 hours of ventilation. Application of positive end-expiratory pressure resulted in significantly decreased standardized histology scores and bronchoalveolar absolute neutrophil counts at low- and high-tidal volume ventilation, respectively. Recruitment maneuvers were essential to maintain pulmonary compliance at both 2 and 4 hrs of ventilation. Signs of ventilator-induced lung injury are evident soon after high tidal volume ventilation (as early as 2 hours) and lung injury worsens with longer-term ventilation (4 hrs). Application of positive end-expiratory pressure and recruitment maneuvers are protective against worsening VILI across all time points. Dynamic compliance can be used guide the frequency

  16. Physiologic Evaluation of Ventilation Perfusion Mismatch and Respiratory Mechanics at Different Positive End-expiratory Pressure in Patients Undergoing Protective One-lung Ventilation.

    Science.gov (United States)

    Spadaro, Savino; Grasso, Salvatore; Karbing, Dan Stieper; Fogagnolo, Alberto; Contoli, Marco; Bollini, Giacomo; Ragazzi, Riccardo; Cinnella, Gilda; Verri, Marco; Cavallesco, Narciso Giorgio; Rees, Stephen Edward; Volta, Carlo Alberto

    2018-03-01

    Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.

  17. The effects of intraoperative lung protective ventilation with positive end-expiratory pressure on blood loss during hepatic resection surgery: A secondary analysis of data from a published randomised control trial (IMPROVE).

    Science.gov (United States)

    Neuschwander, Arthur; Futier, Emmanuel; Jaber, Samir; Pereira, Bruno; Eurin, Mathilde; Marret, Emmanuel; Szymkewicz, Olga; Beaussier, Marc; Paugam-Burtz, Catherine

    2016-04-01

    During high-risk abdominal surgery the use of a multi-faceted lung protective ventilation strategy composed of low tidal volumes, positive end-expiratory pressure (PEEP) and recruitment manoeuvres, has been shown to improve clinical outcomes. It has been speculated, however, that mechanical ventilation using PEEP might increase intraoperative bleeding during liver resection. To study the impact of mechanical ventilation with PEEP on bleeding during hepatectomy. Post-hoc analysis of a randomised controlled trial. Seven French university teaching hospitals from January 2011 to August 2012. Patients scheduled for liver resection surgery. In the Intraoperative Protective Ventilation trial, patients scheduled for major abdominal surgery were randomly assigned to mechanical ventilation using low tidal volume, PEEP between 6 and 8  cmH2O and recruitment manoeuvres (lung protective ventilation strategy) or higher tidal volume, zero PEEP and no recruitment manoeuvres (non-protective ventilation strategy). The primary endpoint was intraoperative blood loss volume. A total of 79 (19.8%) patients underwent liver resections (41 in the lung protective and 38 in the non-protective group). The median (interquartile range) amount of intraoperative blood loss was 500 (200 to 800)  ml and 275 (125 to 800)  ml in the non-protective and lung protective ventilation groups, respectively (P = 0.47). Fourteen (35.0%) and eight (21.5%) patients were transfused in the non-protective and lung protective groups, respectively (P = 0.17), without a statistically significant difference in the median (interquartile range) number of red blood cells units transfused [2.5 (2 to 4) units and 3 (2 to 6) units in the two groups, respectively; P = 0.54]. During hepatic surgery, mechanical ventilation using PEEP within a multi-faceted lung protective strategy was not associated with increased bleeding compared with non-protective ventilation using zero PEEP. The current study was not

  18. Hyperdynamic sepsis modifies a PEEP-mediated redistribution in organ blood flows

    International Nuclear Information System (INIS)

    Bersten, A.D.; Gnidec, A.A.; Rutledge, F.S.; Sibbald, W.J.

    1990-01-01

    Changes in organ blood flow (Q) produced by 20 cm H2O positive end-expiratory pressure (PEEP) were measured before and after the induction of hyperdynamic sepsis in nine unanesthetized sheep. During the baseline nonseptic study, PEEP was associated with a 9% fall in thermodilution-measured systemic Q, although arterial perfusing pressures were unaffected. Concurrently, microsphere-derived Q was maintained to the brain and heart, but fell to liver, spleen, pancreas, kidney, large intestine, and gastrocnemius. Twenty-four to 36 h after cecal ligation and perforation, a pre-PEEP septic study demonstrated an increase in all of the cardiac index (CI) and systemic O2 delivery when compared with the nonseptic study, whereas whole-body O2 extraction was depressed. Although PEEP depressed systemic Q during the septic study to a greater extent than during the nonseptic study (p less than 0.02), absolute organ Q fell only to pancreas, liver, and spleen. Relative to the simultaneous fall in the CI, Q to some splanchnic organs was not depressed by PEEP to the same magnitude in the septic as in the nonseptic study. When an infusion of Ringer's lactate subsequently restored systemic Q to pre-PEEP septic levels, individual flows that had been depressed by PEEP were not restored. Furthermore, Q-kidney continued to fall, such that the postfluid Q-kidney (-19%) was significantly less than was demonstrated in the pre-PEEP septic study. We postulate that differences noted in the distribution of organ Q between the nonseptic and hyperdynamic septic studies after the application of PEEP were secondary to the vasculopathy of sepsis and/or an alteration in the function of specific organ microcirculations. However, these data do not address whether the changes in organ Q distribution after a PEEP-mediated depression in systemic Q during sepsis significantly restricted tissue DO2

  19. Alveolar Tidal recruitment/derecruitment and Overdistension During Four Levels of End-Expiratory Pressure with Protective Tidal Volume During Anesthesia in a Murine Lung-Healthy Model.

    Science.gov (United States)

    Soares, Joao Henrique Neves; Carvalho, Alysson Roncally; Bergamini, Bruno Curty; Gress, Maria Alice Kuster; Jandre, Frederico Caetano; Zin, Walter Araujo; Giannella-Neto, Antonio

    2018-06-01

    We compared respiratory mechanics between the positive end-expiratory pressure of minimal respiratory system elastance (PEEP minErs ) and three levels of PEEP during low-tidal-volume (6 mL/kg) ventilation in rats. Twenty-four rats were anesthetized, paralyzed, and mechanically ventilated. Airway pressure (P aw ), flow (F), and volume (V) were fitted by a linear single compartment model (LSCM) P aw (t) = E rs  × V(t) + R rs  × F(t) + PEEP or a volume- and flow-dependent SCM (VFDSCM) P aw (t) = (E 1  + E 2  × V(t)) × V(t) + (K 1  + K 2  × |F(t)|) × F(t) + PEEP, where E rs and R rs are respiratory system elastance and resistance, respectively; E 1 and E 2 × V are volume-independent and volume-dependent E rs , respectively; and K 1 and K 2  × F are flow-independent and flow-dependent R rs , respectively. Animals were ventilated for 1 h at PEEP 0 cmH 2 O (ZEEP); PEEP minErs ; 2 cmH 2 O above PEEP minErs (PEEP minErs+2 ); or 4 cmH 2 O above PEEP minErs (PEEP minErs+4 ). Alveolar tidal recruitment/derecruitment and overdistension were assessed by the index %E 2  = 100 × [(E 2  × V T )/(E 1  + |E 2 | × V T )], and alveolar stability by the slope of E rs (t). %E 2 varied between 0 and 30% at PEEP minErs in most respiratory cycles. Alveolar Tidal recruitment/derecruitment (%E 2   30) were predominant in the absence of PEEP and in PEEP levels higher than PEEP minErs , respectively. The slope of E rs (t) was different from zero in all groups besides PEEP minErs+4 . PEEP minErs presented the best compromise between alveolar tidal recruitment/derecruitment and overdistension, during 1 h of low-V T mechanical ventilation.

  20. "THE EVALUATION OF THE POSSIBLE EFFECT OF POSITIVE END EXPIRATORY PRESSURE (PEEP) ON PHARMACOKINETICS OF PHENYTOIN IN PATIENTS WITH ACUTE BRAIN INJURY UNDER MECHANICAL VENTILATION."

    OpenAIRE

    "Elham Hadidi; Mojtaba Mojtahedzadeh; Mohammad Reza Rouini; Behzad Eftekhar; Mohammad Abdollahi; Atabak Najafi; Mohammad R. Khajavi; Saeed Rezaee; Reza Ghaffari; Minoo Afshar"

    2005-01-01

    Positive ventilation has shown to have an influence on pharmacokinetic and disposition of some drugs.Beacause phenytoin with a narrow therapautic range, is the most commonly used drug for prophylaxis and treatment of early seizures after acute brain injuries, in the present study the effect of short term PEEP (5-10 cm H2O for at least 8 hours) on phenytoin serum concentration and pharmacokinetic parameters such as Vmax and clearance in brain injured patients under mechanical ventilation was e...

  1. [The influence of positive end-expiratory pressure on cerebral blood flow and cerebrovascular autoregulation in patients with acute respiratory distress syndrome].

    Science.gov (United States)

    Yang, Chunli; Chen, Zhi; Lu, Yuanhua; He, Huiwei; Zeng, Weihua

    2014-05-01

    To explore the influence of different positive end-expiratory pressure (PEEP) levels on cerebral blood flow (CBF) and cerebrovascular autoregulation in patients with acute respiratory distress syndrome(ARDS). A prospective study was conducted. Moderate or severe ARDS patients admitted to Department of Critical Care Medicine of Jiangxi Provincial People's Hospital from January 1st, 2013 to October 1st, 2013 were enrolled. The changes in hemodynamics, respiratory mechanics and gas exchange under different levels of PEEP were observed. CBF velocity of middle cerebral artery (MCA) was measured using transcranial Doppler (TCD), and breath-holding index (BHI) was also calculated. 35 patients with ARDS were included. The oxygenation index (OI), peak inspiratory pressure (PIP), plat pressure (Pplat) and central venous pressure (CVP) were markedly elevated (OI: 324.7±117.2 mmHg vs. 173.4±95.8 mmHg, t=5.913, P=0.000; PIP: 34.7±9.1 cmH2O vs. 26.1±7.9 cmH2O,t=4.222, P=0.000; Pplat: 30.5±8.4 cmH2O vs. 22.2±7.1 cmH2O, t=4.465, P=0.000; CVP: 12.1±3.5 mmHg vs. 8.8±2.2 mmHg, t=4.723, P=0.000) when PEEP was increased from (6.4±1.0) cmH2O to (14.5±2.0) cmH2O (1 cmH2O=0.098 kPa). But no significant difference in the heart rate (85.5±19.1 beats/min vs. 82.7±17.3 beats/min, t=0.643, P=0.523), mean arterial pressure (73.5±12.4 mmHg vs. 76.4±15.1 mmHg, t=0.878, P=0.383) and CBF velocity of MCA [peak systolic flow velocity (Vmax): 91.26±17.57 cm/s vs. 96.64±18.71 cm/s, t=1.240, P=0.219; diastolic flow velocity (Vmin): 31.54±7.71 cm/s vs. 33.87±8.53 cm/s, t=1.199, P=0.235; mean velocity (Vmean): 51.19±12.05 cm/s vs. 54.27±13.36 cm/s, t=1.013, P=0.315] was found. 18 patients with BHI<0.1 at baseline demonstrated that cerebral vasomotor reactivity was poor. BHI was slightly decreased with increase in PEEP (0.78±0.16 vs. 0.86±0.19, t=1.905, P=0.061). Some of moderate or severe ARDS patients without central nervous system disease have independent of preexisting cerebral

  2. Effects of recruitment maneuver and positive end-expiratory pressure on respiratory mechanics and transpulmonary pressure during laparoscopic surgery.

    Science.gov (United States)

    Cinnella, Gilda; Grasso, Salvatore; Spadaro, Savino; Rauseo, Michela; Mirabella, Lucia; Salatto, Potito; De Capraris, Antonella; Nappi, Luigi; Greco, Pantaleo; Dambrosio, Michele

    2013-01-01

    The authors tested the hypothesis that during laparoscopic surgery, Trendelenburg position and pneumoperitoneum may worsen chest wall elastance, concomitantly decreasing transpulmonary pressure, and that a protective ventilator strategy applied after pneumoperitoneum induction, by increasing transpulmonary pressure, would result in alveolar recruitment and improvement in respiratory mechanics and gas exchange. In 29 consecutive patients, a recruiting maneuver followed by positive end-expiratory pressure 5 cm H(2)O maintained until the end of surgery was applied after pneumoperitoneum induction. Respiratory mechanics, gas exchange, blood pressure, and cardiac index were measured before (T(BSL)) and after pneumoperitoneum with zero positive end-expiratory pressure (T(preOLS)), after recruitment with positive end-expiratory pressure (T(postOLS)), and after peritoneum desufflation with positive end-expiratory pressure (T(end)). Esophageal pressure was used for partitioning respiratory mechanics between lung and chest wall (data are mean ± SD): on T(preOLS), chest wall elastance (E(cw)) and elastance of the lung (E(L)) increased (8.2 ± 0.9 vs. 6.2 ± 1.2 cm H(2)O/L, respectively, on T(BSL); P = 0.00016; and 11.69 ± 1.68 vs. 9.61 ± 1.52 cm H(2)O/L on T(BSL); P = 0.0007). On T(postOLS), both chest wall elastance and E(L) decreased (5.2 ± 1.2 and 8.62 ± 1.03 cm H(2)O/L, respectively; P = 0.00015 vs. T(preOLS)), and Pao(2)/inspiratory oxygen fraction improved (491 ± 107 vs. 425 ± 97 on T(preOLS); P = 0.008) remaining stable thereafter. Recruited volume (the difference in lung volume for the same static airway pressure) was 194 ± 80 ml. Pplat(RS) remained stable while inspiratory transpulmonary pressure increased (11.65 + 1.37 cm H(2)O vs. 9.21 + 2.03 on T(preOLS); P = 0.007). All respiratory mechanics parameters remained stable after abdominal desufflation. Hemodynamic parameters remained stable throughout the study. In patients submitted to laparoscopic surgery in

  3. Efecto del incremento de la PEEP en la actividad muscular respiratoria evaluado con electromiografía de superficie en individuos sanos bajo ventilación espontánea

    Directory of Open Access Journals (Sweden)

    Hernández-Valdivieso, Alher Mauricio

    2016-07-01

    Full Text Available Introduction: In a mechanically ventilated patient with increased airway resistance, the expiratory time span is insufficient to exhale all the inspired volume. In order to maintain oxygenation and to reduce the workload of respiratory muscles, it is common to apply an extrinsic positive end-expiratory pressure (PEEP that reduces tissue collapsibility, counterbalancing the increased resistance. Several studies have shown the usefulness of surface electromyography (sEMG to quantify the work of breathing (WOB, particularly in patients with obstructive diseases. Objective: To assess the effect of incremental PEEP in the respiratory muscle activity through sEMG in healthy volunteers noninvasively ventilated. Methods: Study of muscle activity in 10 healthy male volunteers, noninvasively ventilated for 20 minutes. The extrinsic PEEP was applied from 0 to 5 cm H2O in steps of 1 cm H2O at 30 seconds intervals. Results: The bio-potentials of diaphragm and sternocleidomastoid muscles revealed different breathing patterns in response to incremental PEEP: 1 increase in the workload of both muscles during inspiration and expiration; 2 increase in the workload of only one muscle; 3 a remarkable increase in muscle activity only in expiration. Conclusion: In noninvasively ventilated volunteers, sEMG quantitatively relates the PEEP level with changes in sternocleidomastoid and diaphragm activity.

  4. Influence of posture and positive end-tidal expiratory pressure (PEEP) on clearance of Tc99m-DTPA from the lungs

    International Nuclear Information System (INIS)

    Mason, G.R.; Maublant, J.; Sietsema, K.; Effros, R.M.; Mena, I.

    1984-01-01

    The clearance of Tc99m-DTPA aerosols from the lung has been used to detect and quantitate alterations in the permeability of the pulmonary epithelium. Clearance of the radionuclide is accelerated by both chronic and acute injuries to the lung and by smoking. Several laboratories have reported that Tc99m-DTPA clearance from upper lobes exceeded that from lower lobes in upright subjects. To investigate this phenomenon further the authors studied subjects with simultaneous anterior and posterior cameras in upright and supine positions. In the upright position, clearance from both the anterior and posterior upper regions of interest (ROI's) exceeded the lower regions (-1.64 +- .42 S.D. vs. -0.75 +- .41, anterior, p < .05, n=6), -1.04 +- .23 vs. -0.50 +- .36, posterior. All units = %/min. This difference was not observed in the supine subjects. Clearance from the anterior chest exceeded that from the posterior chest in the supine subjects (-1.28 +- .45 vs. -0.05 +- 1.08) and a small increase in radio-activity was observed in at least one ROI of 5 of 6 subjects from the posterior camera. An increase in activity is likely to be secondary to labeling of blood pool, which would have greatest affect where pulmonary blood volume is largest. Computer processing of the entire lung without observer bias in ROI placement showed similar effects of posture over non-peripheral ROI's. Five subjects breathed on PEEP to cause airspace distention, causing clearance to double. Both dependency and airspace distention appear to influence clearance of aerosolized DTPA, the latter may occur by stretching of epithelial pores

  5. Effect of PEEP and inhaled nitric oxide on pulmonary gas exchange during gaseous and partial liquid ventilation with small volumes of perfluorocarbon.

    Science.gov (United States)

    Max, M; Kuhlen, R; Falter, F; Reyle-Hahn, M; Dembinski, R; Rossaint, R

    2000-04-01

    Partial liquid ventilation, positive end-expiratory pressure (PEEP) and inhaled nitric oxide (NO) can improve ventilation/perfusion mismatch in acute lung injury (ALI). The aim of the present study was to compare gas exchange and hemodynamics in experimental ALI during gaseous and partial liquid ventilation at two different levels of PEEP, with and without the inhalation of nitric oxide. Seven pigs (24+/-2 kg BW) were surfactant-depleted by repeated lung lavage with saline. Gas exchange and hemodynamic parameters were assessed in all animals during gaseous and subsequent partial liquid ventilation at two levels of PEEP (5 and 15 cmH2O) and intermittent inhalation of 10 ppm NO. Arterial oxygenation increased significantly with a simultaneous decrease in cardiac output when PEEP 15 cmH2O was applied during gaseous and partial liquid ventilation. All other hemodynamic parameters revealed no relevant changes. Inhalation of NO and instillation of perfluorocarbon had no additive effects on pulmonary gas exchange when compared to PEEP 15 cmH2O alone. In experimental lung injury, improvements in gas exchange are most distinct during mechanical ventilation with PEEP 15 cmH2O without significantly impairing hemodynamics. Partial liquid ventilation and inhaled NO did not cause an additive increase of PaO2.

  6. Effect of Positive End-Expiratory Pressure on Central Venous Pressure in Patients under Mechanical Ventilation.

    Science.gov (United States)

    Shojaee, Majid; Sabzghabaei, Anita; Alimohammadi, Hossein; Derakhshanfar, Hojjat; Amini, Afshin; Esmailzadeh, Bahareh

    2017-01-01

    Finding the probable governing pattern of PEEP and CVP changes is an area of interest for in-charge physicians and researchers. Therefore, the present study was designed with the aim of evaluating the relationship between the mentioned pressures. In this quasi-experimental study, patients under mechanical ventilation were evaluated with the aim of assessing the effect of PEEP change on CVP. Non-trauma patients, over 18 years of age, who were under mechanical ventilation and had stable hemodynamics, with inserted CV line were entered. After gathering demographic data, patients underwent 0, 5, and 10 cmH 2 O PEEPs and the respective CVPs of the mentioned points were recorded. The relationship of CVP and PEEP in different cut points were measured using SPSS 21.0 statistical software. 60 patients with the mean age of 73.95 ± 11.58 years were evaluated (68.3% male). The most frequent cause of ICU admission was sepsis with 45.0%. 5 cmH 2 O increase in PEEP led to 2.47 ± 1.53 mean difference in CVP level. If the PEEP baseline is 0 at the time of 5 cmH 2 O increase, it leads to a higher raise in CVP compared to when the baseline is 5 cmH 2 O (2.47 ± 1.53 vs. 1.57 ± 1.07; p = 0.039). The relationship between CVP and 5 cmH 2 O (p = 0.279), and 10 cmH 2 O (p = 0.292) PEEP changes were not dependent on the baseline level of CVP. The findings of this study revealed the direct relationship between PEEP and CVP. Approximately, a 5 cmH 2 O increase in PEEP will be associated with about 2.5 cmH 2 O raise in CVP. When applying a 5 cmH 2 O PEEP increase, if the baseline PEEP is 0, it leads to a significantly higher raise in CVP compared to when it is 5 cmH 2 O (2.5 vs. 1.6). It seems that sex, history of cardiac failure, baseline CVP level, and hypertension do not have a significant effect in this regard.

  7. Effect of Positive End-Expiratory Pressure on Central Venous Pressure in Patients under Mechanical Ventilation

    Directory of Open Access Journals (Sweden)

    Majid Shojaee

    2016-12-01

    Full Text Available Introduction: Finding the probable governing pattern of PEEP and CVP changes is an area of interest for in-charge physicians and researchers. Therefore, the present study was designed with the aim of evaluating the relationship between the mentioned pressures. Methods: In this quasi-experimental study, patients under mechanical ventilation were evaluated with the aim of assessing the effect of PEEP change on CVP. Non-trauma patients, over 18 years of age, who were under mechanical ventilation and had stable hemodynamics, with inserted CV line were entered. After gathering demographic data, patients underwent 0, 5, and 10 cmH2O PEEPs and the respective CVPs of the mentioned points were recorded. The relationship of CVP and PEEP in different cut points were measured using SPSS 21.0 statistical software. Results: 60 patients with the mean age of 73.95 ± 11.58 years were evaluated (68.3% male. The most frequent cause of ICU admission was sepsis with 45.0%. 5 cmH2O increase in PEEP led to 2.47 ± 1.53 mean difference in CVP level. If the PEEP baseline is 0 at the time of 5 cmH2O increase, it leads to a higher raise in CVP compared to when the baseline is 5 cmH2O (2.47 ± 1.53 vs. 1.57 ± 1.07; p = 0.039. The relationship between CVP and 5 cmH2O (p = 0.279, and 10 cmH2O (p = 0.292 PEEP changes were not dependent on the baseline level of CVP. Conclusion: The findings of this study revealed the direct relationship between PEEP and CVP. Approximately, a 5 cmH2O increase in PEEP will be associated with about 2.5 cmH2O raise in CVP. When applying a 5 cmH2O PEEP increase, if the baseline PEEP is 0, it leads to a significantly higher raise in CVP compared to when it is 5 cmH2O (2.5 vs. 1.6. It seems that sex, history of cardiac failure, baseline CVP level, and hypertension do not have a significant effect in this regard.

  8. Multi-detector CT evaluation in patients suspected of tracheobronchomalacia: Comparison of end-expiratory with dynamic expiratory volumetric acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    Ferretti, Gilbert R. [Department of Radiology (France)], E-mail: gferretti@chu-grenoble.fr; Jankowski, Adrien [Department of Radiology (France)], E-mail: ajankowski@chu-grenoble.fr; Perrin, Marie Amelie [Department of Radiology (France)], E-mail: maperrin@chu-grenoble.fr; Chouri, Nathalie [Department of Respiratory Diseases (France)], E-mail: nchouri@chu-grenoble.fr; Arnol, Nathalie [Sleep Laboratory and EFCR, University Hospital, Grenoble (France); HP2 Laboratory, INSERM ERI 0017 (Hypoxia: Pathophysiology), Joseph Fourier University, Grenoble (France)], E-mail: narnold@chu-grenoble.fr; Aubaud, Laurent [Department of Radiology (France)], E-mail: laubaud@chu-grenoble.fr; Pepin, Jean-Louis [Sleep Laboratory and EFCR, University Hospital, Grenoble (France); HP2 Laboratory, INSERM ERI 0017 (Hypoxia: Pathophysiology), Joseph Fourier University, Grenoble (France)], E-mail: jlpepin@chu-grenoble.fr

    2008-11-15

    Purpose: The aim of this study was to compare dynamic expiratory imaging and end-expiratory imaging using multi-detector CT (MDCT) of the central airways in patients suspected of tracheobronchomalacia (TBM). Methods: This study had local ethical committee approval. Seventy patients suspected of TBM were prospectively included. All patients underwent evaluation of central airways by three different low-dose MDCT acquisitions: end inspiration, end expiration, and dynamic expiration. Degree of airway collapse was measured by calculating the percentage change in the area and diameter of the airways between inspiratory and the two expiratory techniques at three levels of the trachea and in the sagittal diameter of the right and left main bronchi. Three threshold levels of percentage reduction in diameter or area (30%, 50%, and 70%) for defining TBM were evaluated. Results: In the entire population, the mean percentage of airway collapse was significantly greater with dynamic expiratory imaging than with the end-expiratory imaging at three different levels: lower thoracic trachea (26% vs. 16.6%, p < 0.009), right (25.2% vs. 14%, p < 0.01) and left main (24.7% vs. 13.3%, p < 0.01) bronchus. Whatever the threshold value for defining TBM, dynamic expiratory imaging always resulted in diagnosing TBM in more patients than end-expiratory imaging. Conclusions: Dynamic expiratory imaging shows a significantly greater degree and a significantly greater extent of airway collapse than standard end-expiratory imaging in patients suspected of TBM. Further evaluation of the clinical relevance of such findings is warranted.

  9. Positional effects on distribution of ventilation in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Shim, C.; Chun, K.J.; Williams, M.H. Jr.; Blaufox, M.D.

    1986-01-01

    Ventilation is distributed predominantly to the dependent lung in normal persons in the decubitus position. We evaluated the distribution of ventilation in four patients with mild-to-moderate chronic obstructive pulmonary disease using 81mKr gas. Patients were tested in the sitting and right and left decubitus positions with and without the application of positive end expiratory pressure (PEEP). In contrast to findings in controls, ventilation was predominantly distributed to the nondependent lung in patients in the decubitus position. Mean ventilation in the right lung decreased from 51% of the total in the sitting position to 31% in the right decubitus position; it increased with the application of 10 cm PEEP. Reduced ventilation in the dependent lung most likely is caused by closure of the airways after a decrease in volume. Application of PEEP resulted in increased lung volume and preferential distribution of ventilation to the dependent lung

  10. Evaluation of lung and chest wall mechanics during anaesthesia using the PEEP-step method.

    Science.gov (United States)

    Persson, P; Stenqvist, O; Lundin, S

    2018-04-01

    Postoperative pulmonary complications are common. Between patients there are differences in lung and chest wall mechanics. Individualised mechanical ventilation based on measurement of transpulmonary pressures would be a step forward. A previously described method evaluates lung and chest wall mechanics from a change of ΔPEEP and calculation of change in end-expiratory lung volume (ΔEELV). The aim of the present study was to validate this PEEP-step method (PSM) during general anaesthesia by comparing it with the conventional method using oesophageal pressure (PES) measurements. In 24 lung healthy subjects (BMI 18.5-32), three different sizes of PEEP steps were performed during general anaesthesia and ΔEELVs were calculated. Transpulmonary driving pressure (ΔPL) for a tidal volume equal to each ΔEELV was measured using PES measurements and compared to ΔPEEP with limits of agreement and intraclass correlation coefficients (ICC). ΔPL calculated with both methods was compared with a Bland-Altman plot. Mean differences between ΔPEEP and ΔPL were mechanical properties among the lung healthy patients stresses the need for individualised ventilator settings based on measurements of lung and chest wall mechanics. The agreement between ΔPLs measured by the two methods during general anaesthesia suggests the use of the non-invasive PSM in this patient population. NCT 02830516. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Lung recruitability is better estimated according to the Berlin definition of acute respiratory distress syndrome at standard 5 cm H2O rather than higher positive end-expiratory pressure: a retrospective cohort study.

    Science.gov (United States)

    Caironi, Pietro; Carlesso, Eleonora; Cressoni, Massimo; Chiumello, Davide; Moerer, Onner; Chiurazzi, Chiara; Brioni, Matteo; Bottino, Nicola; Lazzerini, Marco; Bugedo, Guillermo; Quintel, Michael; Ranieri, V Marco; Gattinoni, Luciano

    2015-04-01

    The Berlin definition of acute respiratory distress syndrome has introduced three classes of severity according to PaO2/FIO2 thresholds. The level of positive end-expiratory pressure applied may greatly affect PaO2/FIO2, thereby masking acute respiratory distress syndrome severity, which should reflect the underlying lung injury (lung edema and recruitability). We hypothesized that the assessment of acute respiratory distress syndrome severity at standardized low positive end-expiratory pressure may improve the association between the underlying lung injury, as detected by CT, and PaO2/FIO2-derived severity. Retrospective analysis. Four university hospitals (Italy, Germany, and Chile). One hundred forty-eight patients with acute lung injury or acute respiratory distress syndrome according to the American-European Consensus Conference criteria. Patients underwent a three-step ventilator protocol (at clinical, 5 cm H2O, or 15 cm H2O positive end-expiratory pressure). Whole-lung CT scans were obtained at 5 and 45 cm H2O airway pressure. Nine patients did not fulfill acute respiratory distress syndrome criteria of the novel Berlin definition. Patients were then classified according to PaO2/FIO2 assessed at clinical, 5 cm H2O, or 15 cm H2O positive end-expiratory pressure. At clinical positive end-expiratory pressure (11±3 cm H2O), patients with severe acute respiratory distress syndrome had a greater lung tissue weight and recruitability than patients with mild or moderate acute respiratory distress syndrome (pBerlin definition of acute respiratory distress syndrome assessed at 5 cm H2O allows a better evaluation of lung recruitability and edema than at higher positive end-expiratory pressure clinically set.

  12. Effects of vertical positioning on gas exchange and lung volumes in acute respiratory distress syndrome.

    Science.gov (United States)

    Richard, Jean-Christophe M; Maggiore, Salvatore Maurizio; Mancebo, Jordi; Lemaire, François; Jonson, Bjorn; Brochard, Laurent

    2006-10-01

    Supine position may contribute to the loss of aerated lung volume in patients with acute respiratory distress syndrome (ARDS). We hypothesized that verticalization increases lung volume and improves gas exchange by reducing the pressure surrounding lung bases. Prospective observational physiological study in a medical ICU. In 16 patients with ARDS we measured arterial blood gases, pressure-volume curves of the respiratory system recorded from positive-end expiratory pressure (PEEP), and changes in lung volume in supine and vertical positions (trunk elevated at 45 degrees and legs down at 45 degrees ). Vertical positioning increased PaO(2) significantly from 94+/-33 to 142+/-49 mmHg, with an increase higher than 40% in 11 responders. The volume at 20 cmH(2)O measured on the PV curve from PEEP increased using the vertical position only in responders (233+/-146 vs. -8+/-9 1ml in nonresponders); this change was correlated to oxygenation change (rho=0.55). End-expiratory lung volume variation from supine to vertical and 1 h later back to supine, measured in 12 patients showed a significant increase during the 1-h upright period in responders (n=7) but not in nonresponders (n=5; 215+/-220 vs. 10+/-22 ml), suggesting a time-dependent recruitment. Vertical positioning is a simple technique that may improve oxygenation and lung recruitment in ARDS patients.

  13. Monitoring of intratidal lung mechanics: a Graphical User Interface for a model-based decision support system for PEEP-titration in mechanical ventilation.

    Science.gov (United States)

    Buehler, S; Lozano-Zahonero, S; Schumann, S; Guttmann, J

    2014-12-01

    In mechanical ventilation, a careful setting of the ventilation parameters in accordance with the current individual state of the lung is crucial to minimize ventilator induced lung injury. Positive end-expiratory pressure (PEEP) has to be set to prevent collapse of the alveoli, however at the same time overdistension should be avoided. Classic approaches of analyzing static respiratory system mechanics fail in particular if lung injury already prevails. A new approach of analyzing dynamic respiratory system mechanics to set PEEP uses the intratidal, volume-dependent compliance which is believed to stay relatively constant during one breath only if neither atelectasis nor overdistension occurs. To test the success of this dynamic approach systematically at bedside or in an animal study, automation of the computing steps is necessary. A decision support system for optimizing PEEP in form of a Graphical User Interface (GUI) was targeted. Respiratory system mechanics were analyzed using the gliding SLICE method. The resulting shapes of the intratidal compliance-volume curve were classified into one of six categories, each associated with a PEEP-suggestion. The GUI should include a graphical representation of the results as well as a quality check to judge the reliability of the suggestion. The implementation of a user-friendly GUI was successfully realized. The agreement between modelled and measured pressure data [expressed as root-mean-square (RMS)] tested during the implementation phase with real respiratory data from two patient studies was below 0.2 mbar for data taken in volume controlled mode and below 0.4 mbar for data taken in pressure controlled mode except for two cases with RMS rational decision-making model for PEEP-titration.

  14. Efeitos de diferentes volumes correntes e da pressão expiratória final positiva sobre a troca gasosa na fístula broncopleural experimental Effects of different tidal volumes and positive end expiratory pressure on gas exchange in experimental bronchopleural fistula

    Directory of Open Access Journals (Sweden)

    Maria Gabriela Cavicchia Toneloto

    2008-09-01

    melhora e o débito da fístula é reduzido quando comparado ao volume corrente de 10ml/Kg. Um baixo volume resulta em hipercapnia e grave dessaturação. Finalmente, em qualquer volume corrente, PEEP aumenta o débito da fístula e diminui a ventilação alveolar.OBJECTIVES: The present study was designed to identify the effect of positive end expiratory pressure (PEEP and the ideal pulmonary tidal volume to ventilate animals with a surgically produced bronchopleural fistula, aiming to reduce fistula output without affecting gas exchange. METHODS: Hemodynamic and respiratory assessment of gas exchange was obtained in five, healthy, young, mechanically ventilated Large White pigs under volume controlled ventilation with FiO2 of 0.4 and an inspiration:expiration ratio of 1:2, keeping respiratory rate at 22 cpm. A bronchopleural fistula was produced by resection of the lingula. Underwater seal drainage was installed and the thorax was hermetically closed. Gas exchange and fistula output were measured with the animals ventilated sequentially with tidal volumes of 4 ml/kg, 7 ml/kg and 10 ml/Kg alternating zero of positive end expiratory pressure (ZEEP and PEEP of 10 cmH2O, always in the same order. RESULTS: These findings are attributed to reduced alveolar ventilation and ventilation/perfusion abnormalities and were attenuated with larger tidal volumes. PEEP increases air leak, even with low volume (of 2.0 ± 2.8mL to 31 ± 20.7mL; p= 0.006 and decreases alveolar ventilation in all tidal volumes. Alveolar ventilation improved with larger tidal volumes, but increased fistula output (10 mL/kg - 25.8 ± 18.3mL to 80.2 ± 43.9mL; p=0.0010. Low tidal volumes result in hypercapnia (ZEEP - Toneloto MGC, Terzi RGG, Silva WA, Moraes AC, Moreira MM 83.7± 6.9 mmHg and with PEEP 10 - 93 ± 10.1mmHg and severely decreased arterial oxygen saturation, about of 84%. CONCLUSIONS: The tidal volume of 7 ml/Kg with ZEEP was considered the best tidal volume because, despite moderate hypercapnia

  15. Is increased positive end-expiratory pressure the culprit? Autoresuscitation in a 44-year-old man after prolonged cardiopulmonary resuscitation: a case report

    OpenAIRE

    Hagmann, Henning; Oelmann, Katrin; Stangl, Robert; Michels, Guido

    2016-01-01

    Background The phenomenon of autoresuscitation is rare, yet it is known to most emergency physicians. However, the pathophysiology of the delayed return of spontaneous circulation remains enigmatic. Among other causes hyperinflation of the lungs and excessively high positive end-expiratory pressure have been suggested, but reports including cardiopulmonary monitoring during cardiopulmonary resuscitation are scarce to support this hypothesis. Case presentation We report a case of autoresuscita...

  16. Intraoperative and postoperative evaluation of low tidal volume combined with low-level positive end-expiratory pressure ventilation in laparoscopic surgery in elderly patients

    Directory of Open Access Journals (Sweden)

    Ye-Qiu Li

    2016-01-01

    Full Text Available Objective: To evaluate intraoperative and postoperative condition of low tidal volume combined with low-level positive end-expiratory pressure ventilation in laparoscopic surgery in elderly patients. Methods: A total of 176 cases of elderly patients (more than 60 years old receiving laparoscopic surgery in our hospital from July 2013 to July 2015 were selected as research subjects and randomly divided into observation group and control group, each group included 88 cases, control group received conventional ventilation strategy, observation group received low tidal volume combined with low-level positive end-expiratory pressure ventilation strategy, and then levels of hemodynamic indexes, respiratory mechanical indexes, serology indexes and cerebral vessel related indexes, etc of two groups were compared. Results: Intraoperative and postoperative heart rate and mean arterial pressure levels of observation group were lower than those of control group, arterial partial pressure of oxygen and oxygenation index levels were higher than those of control group and differences had statistical significance (P<0.05; intraoperative APIP and Pplat values of observation group were lower than those of control group, Cs value was higher than that of control group and differences had statistical significance (P<0.05; intraoperative and postoperative serum IL-8 and TNF-α levels of observation group were lower than those of control group, IL-10 level was higher than that of control group and differences had statistical significance (P<0.05; intraoperative and postoperative PjvO2, SjvO2 and CjvO2 levels of observation group were higher than those of control group, Da-jvO2 level was lower than that of control group and differences had statistical significance (P<0.05. Conclusions: When elderly patients receive laparoscopic surgery, the use of low tidal volume combined with low-level positive end-expiratory pressure ventilation strategy can stabilize hemodynamic

  17. compliance of the respiratory system as a predictor for successful

    African Journals Online (AJOL)

    clinical, ventilatory and blood gas criteria were studied. ... pressure (PIP) and positive end-expiratory pressure (PEEP) represented ... criteria for extubation, we found that bedside measurement of total ... position in neutral head-neck posture.

  18. Avaliação da função pulmonar de recém-nascidos com síndrome do desconforto respiratório em diferentes pressões finais expiratórias positivas Assessment of pulmonary function of preterm newborn infants with respiratory distress syndrome at different positive end expiratory pressure levels

    Directory of Open Access Journals (Sweden)

    Luiz C.T. Consolo

    2002-09-01

    Full Text Available RESUMO\tABSTRACT \t Objetivo: verificar as alterações da função pulmonar: complacência dinâmica (Cdyn, volume corrente inspiratório (V Tinsp, pressão arterial de dióxido de carbono (PaCO2, em recém-nascidos pré-termo com síndrome do desconforto respiratório. Pacientes e Métodos: estudo de caso controle, incluindo 11 pré-termos com idade gestacional Objective: to verify the alterations of pulmonary function in preterm newborn infants with respiratory distress syndrome (RDS. The parameters analyzed were Dynamic Compliance (Cdyn, Inspiratory Tidal Volume (TVinsp, partial arterial pressure of carbon dioxide (PaCO2. Methods: eleven preterm newborn infants, with gestational age < 35 weeks, and birth weight < 2.500 g, were include in a control case study. All infants presented RDS and were treated with 120 mg/Kg of porcine surfactant. The initial positive end expiratory pressure (PEEP was 3 cm H2O. A pneumotachograph with a graphical monitor was used to assess the pulmonary function. After each increase in the PEEP (4 and 6 cm H2O, there was an interval of 20 minutes before measuring the arterial data of pulmonary function and arterial gases. Results: there were three males and eight females (1:2,7 among the infants with RDS. The mean gestational age was 30.78. 2.05 weeks, ranging from 26 to 34 weeks. The increase in the PEEP from 3 to 6 cm H2O caused significant decrease in the TVinsp (6.46 ±3.43 to 4.20 ±2.35, P=0.0262. With the increase in the PEEP from 4 to 6 cm H2O, there was also a decrease in the TVinsp (5.98.± 3.33 to 4.20.± 2.35, (P=0.0044. Regarding the Cdyn, when there was an increase in the PEEP from 3 to 6 cm H2O, the reduction was statistically significant (0.58.± 0.27 to 0.46± 0.25, P=0.0408 and from 4 to 6 cm H2O, the reduction in the Cdyn was also important (0.77± 0.27 to 0.46± 0.25, (P=0.0164. Increases in the PEEP from 4 to 6 cm H2O caused increases in the PaCO2 (52.81± 15.49 to 64.90± 12.69, (P= 0,0141. A

  19. Intrinsic positive end-expiratory pressure during one-lung ventilation of patients with pulmonary hyperinflation. Influence of low respiratory rate with unchanged minute volume.

    Science.gov (United States)

    Szegedi, L L; Barvais, L; Sokolow, Y; Yernault, J C; d'Hollander, A A

    2002-01-01

    We measured lung mechanics and gas exchange during one-lung ventilation (OLV) of patients with chronic obstructive pulmonary disease, using three respiratory rates (RR) and unchanged minute volume. We studied 15 patients about to undergo lung surgery, during anaesthesia, and placed in the lateral position. Ventilation was with constant minute volume, inspiratory flow and FIO2. For periods of 15 min, RR of 5, 10, and 15 bpm were applied in a random sequence and recordings were made of lung mechanics and an arterial blood gas sample was taken. Data were analysed with the repeated measures ANOVA and paired t-test with Bonferroni correction. PaO2 changes were not significant. At the lowest RR, PaCO2 decreased (from 42 (SD 4) mm Hg at RR 15-41 (4) mm Hg at RR 10 and 39 (4) mm Hg at RR 5, P<0.01), and end-tidal carbon dioxide increased (from 33 (5) mm Hg at RR 15 to 35 (5) mm Hg at RR 10 and 36 (6) mm Hg at RR 5, P<0.01). Intrinsic positive end-expiratory pressure (PEEPi) was reduced even with larger tidal volumes (from 6 (4) cm H2O at RR 15-5 (4) cm H2O at RR 10, and 3 (3) cm H2O at RR 5, P<0.01), most probably caused by increased expiratory time at the lowest RR. A reduction in RR reduces PEEPi and hypercapnia during OLV in anaesthetized patients with chronic obstructive lung disease.

  20. Partial liquid ventilation improves lung function in ventilation-induced lung injury

    NARCIS (Netherlands)

    G.F. Vazquez de Anda; R.A. Lachmann; S.J.C. Verbrugge (Serge); D.A.M.P.J. Gommers (Diederik); J.J. Haitsma (Jack); B.F. Lachmann (Burkhard)

    2001-01-01

    textabstractDisturbances in lung function and lung mechanics are present after ventilation with high peak inspiratory pressures (PIP) and low levels of positive end-expiratory pressure (PEEP). Therefore, the authors investigated whether partial liquid ventilation can re-establish

  1. Prevention of pectus excavatum for children with spinal muscular atrophy type 1.

    Science.gov (United States)

    Bach, John R; Bianchi, Carlo

    2003-10-01

    To demonstrate the elimination of pectus excavatum and promotion of more normal lung growth and chest wall development by the use of high-span positive inspiratory pressure plus positive end-expiratory pressure (PIP+PEEP), patients with spinal muscular atrophy type 1 with paradoxical breathing were placed on high-span PIP+PEEP when sleeping from the point of diagnosis of spinal muscular atrophy. Although the appearance of pectus excavatum is ubiquitous in untreated infants with spinal muscular atrophy type 1, after institution of high-span PIP+PEEP, pectus resolves and lungs and chest walls grow more normally. High-span PIP+PEEP is indicated for all infants diagnosed with spinal muscular atrophy who demonstrate paradoxical breathing for the purpose of promoting more normal lung and chest development.

  2. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  3. Application of the Novel Ventilation Mode FLow-Controlled EXpiration (FLEX): A Crossover Proof-of-Principle Study in Lung-Healthy Patients.

    Science.gov (United States)

    Wirth, Steffen; Springer, Sebastian; Spaeth, Johannes; Borgmann, Silke; Goebel, Ulrich; Schumann, Stefan

    2017-10-01

    Traditionally, mechanical ventilation is achieved via active lung inflation during inspiration and passive lung emptying during expiration. By contrast, the novel FLEX (FLow-controlled EXpiration) ventilator mode actively decreases the rate of lung emptying. We investigated whether FLEX can be used during intraoperative mechanical ventilation of lung-healthy patients. In 30 adult patients scheduled for neurosurgical procedures, we studied respiratory system mechanics, regional ventilation, oxygenation, and hemodynamics during ventilation with and without FLEX at positive end-expiratory pressure (PEEP) of 5 and 7 cm H2O. The FLEX system was integrated into the expiratory limb and modified the expiratory flow profile by continuously changing expiratory resistance according to a computer-controlled algorithm. Mean airway pressure increased with PEEP by 1.9 cm H2O and with FLEX by 1 cm H2O (all P ventilated during general anesthesia. FLEX improves the homogeneous distribution of ventilation in the lungs.

  4. Lung-protective perioperative mechanical ventilation

    NARCIS (Netherlands)

    Hemmes, S.N.T.

    2015-01-01

    Intraoperative ventilation has the potential to cause lung injury and possibly increase risk of pulmonary complications after surgery. Use of large tidal volumes could cause overdistension of lung tissue, which can be aggravated by too high levels of positive end-expiratory pressure (PEEP). Too low

  5. The effect of lung deflation on the position of the pleura during subclavian vein cannulation in infants receiving mechanical ventilation: an ultrasound study.

    Science.gov (United States)

    Jang, Y-E; Lee, J-H; Park, Y-H; Byon, H-J; Kim, H-S; Kim, C-S; Kim, J-T

    2013-10-01

    We evaluated the effect of lung deflation on the relative position of the pleura compared with a reference line during supra- and infraclavicular approaches to the right subclavian vein. The reference line was drawn relative to the predicted pathway of the needle. The distances between the pleura and the reference line for supra- and infraclavicular approaches were measured during inspiration and expiration in 41 infants. Measurements were repeated with the application of 5 cmH2O positive end-expiratory pressure (PEEP) and in the Trendelenburg position. Lung deflation during the supraclavicular approach significantly decreased the volume of lung crossing the reference line by a median (IQR [range]) of 1.0 (0.6 to 1.3 [0.0 to 4.8]) mm, p deflation showed no change in the distance of the pleura from the reference line regardless of PEEP or patient position. We conclude that lung deflation moves the lung apex caudally and can reduce the potential risk of pneumothorax during a supraclavicular approach to the right subclavian vein in infants. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  6. High tidal volume ventilation in infant mice.

    Science.gov (United States)

    Cannizzaro, Vincenzo; Zosky, Graeme R; Hantos, Zoltán; Turner, Debra J; Sly, Peter D

    2008-06-30

    Infant mice were ventilated with either high tidal volume (V(T)) with zero end-expiratory pressure (HVZ), high V(T) with positive end-expiratory pressure (PEEP) (HVP), or low V(T) with PEEP. Thoracic gas volume (TGV) was determined plethysmographically and low-frequency forced oscillations were used to measure the input impedance of the respiratory system. Inflammatory cells, total protein, and cytokines in bronchoalveolar lavage fluid (BALF) and interleukin-6 (IL-6) in serum were measured as markers of pulmonary and systemic inflammatory response, respectively. Coefficients of tissue damping and tissue elastance increased in all ventilated mice, with the largest rise seen in the HVZ group where TGV rapidly decreased. BALF protein levels increased in the HVP group, whereas serum IL-6 rose in the HVZ group. PEEP keeps the lungs open, but provides high volumes to the entire lungs and induces lung injury. Compared to studies in adult and non-neonatal rodents, infant mice demonstrate a different response to similar ventilation strategies underscoring the need for age-specific animal models.

  7. Surfactant impairment after mechanical ventilation with large alveolar surface area changes and effects of positive end-expiratory pressure

    NARCIS (Netherlands)

    S.J.C. Verbrugge (Serge); S.H. Bohm; D.A.M.P.J. Gommers (Diederik); L.J.I. Zimmermann (Luc); B.F. Lachmann (Burkhard)

    1998-01-01

    textabstractWe have assessed the effects of overinflation on surfactant function and composition in rats undergoing ventilation for 20 min with 100% oxygen at a peak inspiratory pressure of 45 cm H2O, with or without PEEP 10 cm H2O (groups 45/10 and 45/0, respectively).

  8. Persistent puhnonary hypertension ofthe neonate in a developing ...

    African Journals Online (AJOL)

    the study period. Their clinical characteristics are dis- played in Tables IT and ITl. Comparison of the clinical, ventilatory and laboratory findings of the survivors v. the non-survivors .... Fio, = fractional concentration of inspired oxygen; PEEP = positive end expiratory ... had multi-organ failure and was assessed as having a.

  9. Intraoperative protective mechanical ventilation for prevention of postoperative pulmonary complications: a comprehensive review of the role of tidal volume, positive end-expiratory pressure, and lung recruitment maneuvers.

    Science.gov (United States)

    Güldner, Andreas; Kiss, Thomas; Serpa Neto, Ary; Hemmes, Sabrine N T; Canet, Jaume; Spieth, Peter M; Rocco, Patricia R M; Schultz, Marcus J; Pelosi, Paolo; Gama de Abreu, Marcelo

    2015-09-01

    Postoperative pulmonary complications are associated with increased morbidity, length of hospital stay, and mortality after major surgery. Intraoperative lung-protective mechanical ventilation has the potential to reduce the incidence of postoperative pulmonary complications. This review discusses the relevant literature on definition and methods to predict the occurrence of postoperative pulmonary complication, the pathophysiology of ventilator-induced lung injury with emphasis on the noninjured lung, and protective ventilation strategies, including the respective roles of tidal volumes, positive end-expiratory pressure, and recruitment maneuvers. The authors propose an algorithm for protective intraoperative mechanical ventilation based on evidence from recent randomized controlled trials.

  10. Rationale and study design of PROVHILO - a worldwide multicenter randomized controlled trial on protective ventilation during general anesthesia for open abdominal surgery.

    Science.gov (United States)

    Hemmes, Sabrine N T; Severgnini, Paolo; Jaber, Samir; Canet, Jaume; Wrigge, Hermann; Hiesmayr, Michael; Tschernko, Edda M; Hollmann, Markus W; Binnekade, Jan M; Hedenstierna, Göran; Putensen, Christian; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2011-05-06

    Post-operative pulmonary complications add to the morbidity and mortality of surgical patients, in particular after general anesthesia >2 hours for abdominal surgery. Whether a protective mechanical ventilation strategy with higher levels of positive end-expiratory pressure (PEEP) and repeated recruitment maneuvers; the "open lung strategy", protects against post-operative pulmonary complications is uncertain. The present study aims at comparing a protective mechanical ventilation strategy with a conventional mechanical ventilation strategy during general anesthesia for abdominal non-laparoscopic surgery. The PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure ("PROVHILO") trial is a worldwide investigator-initiated multicenter randomized controlled two-arm study. Nine hundred patients scheduled for non-laparoscopic abdominal surgery at high or intermediate risk for post-operative pulmonary complications are randomized to mechanical ventilation with the level of PEEP at 12 cmH(2)O with recruitment maneuvers (the lung-protective strategy) or mechanical ventilation with the level of PEEP at maximum 2 cmH(2)O without recruitment maneuvers (the conventional strategy). The primary endpoint is any post-operative pulmonary complication. The PROVHILO trial is the first randomized controlled trial powered to investigate whether an open lung mechanical ventilation strategy in short-term mechanical ventilation prevents against postoperative pulmonary complications. ISRCTN: ISRCTN70332574.

  11. Effect of intraoperative PEEP application on colonic anastomoses healing: An experimental animal study.

    Science.gov (United States)

    Turkoglu, Mehmet; Bostancı, Erdal Birol; Bilgili, Hasan; Türkoğlu, Yıldız; Karadeniz, Ümit; Aydoğ, Gülden; Erçin, Uğur; Bilgihan, Ayşe; Özer, İlter; Akoğlu, Musa

    2015-07-27

    This study aimed to assess the effect of intraoperative PEEP intervention on the healing of colonic anastomoses in rabbits. Thirty-two New Zealand type male rabbits were divided into two groups of sixteen animals each. Following ventilation with tracheostomy, colonic resection and anastomosis were performed in both groups. While 10 cm H2O PEEP level was applied in Group I (PEEP), Group II (ZEEP) was ventilated without PEEP throughout the surgery. Half of the both PEEP and ZEEP group animals were killed on the third postoperative day, while the remaining half on the seventh. Anastomotic bursting pressures, the tissue concentrations in hydroxyproline, and histological assessments were performed. Besides, intraoperative oxygen saturation and postoperative arterial blood gas parameters were also compared. On the first postoperative day, both arterial oxygen tension (PO2) and oxygen saturation (SO2) in the PEEP group were significantly higher than in the ZEEP group. On the seventh postoperative day, the bursting pressures of the anastomoses were significantly higher in the PEEP group, however the hydroxyproline content was significantly lower in the PEEP group than that in the ZEEP group. At day 7, PEEP group was significantly associated with increased neoangiogenesis compared with the ZEEP group. The anastomotic healing process is positively influenced by the intraoperative PEEP application.

  12. Model-based PEEP optimisation in mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Chiew Yeong Shiong

    2011-12-01

    Full Text Available Abstract Background Acute Respiratory Distress Syndrome (ARDS patients require mechanical ventilation (MV for breathing support. Patient-specific PEEP is encouraged for treating different patients but there is no well established method in optimal PEEP selection. Methods A study of 10 patients diagnosed with ALI/ARDS whom underwent recruitment manoeuvre is carried out. Airway pressure and flow data are used to identify patient-specific constant lung elastance (Elung and time-variant dynamic lung elastance (Edrs at each PEEP level (increments of 5cmH2O, for a single compartment linear lung model using integral-based methods. Optimal PEEP is estimated using Elung versus PEEP, Edrs-Pressure curve and Edrs Area at minimum elastance (maximum compliance and the inflection of the curves (diminishing return. Results are compared to clinically selected PEEP values. The trials and use of the data were approved by the New Zealand South Island Regional Ethics Committee. Results Median absolute percentage fitting error to the data when estimating time-variant Edrs is 0.9% (IQR = 0.5-2.4 and 5.6% [IQR: 1.8-11.3] when estimating constant Elung. Both Elung and Edrs decrease with PEEP to a minimum, before rising, and indicating potential over-inflation. Median Edrs over all patients across all PEEP values was 32.2 cmH2O/l [IQR: 26.1-46.6], reflecting the heterogeneity of ALI/ARDS patients, and their response to PEEP, that complicates standard approaches to PEEP selection. All Edrs-Pressure curves have a clear inflection point before minimum Edrs, making PEEP selection straightforward. Model-based selected PEEP using the proposed metrics were higher than clinically selected values in 7/10 cases. Conclusion Continuous monitoring of the patient-specific Elung and Edrs and minimally invasive PEEP titration provide a unique, patient-specific and physiologically relevant metric to optimize PEEP selection with minimal disruption of MV therapy.

  13. Positive expiratory pressure - Common clinical applications and physiological effects.

    Science.gov (United States)

    Fagevik Olsén, Monika; Lannefors, Louise; Westerdahl, Elisabeth

    2015-03-01

    Breathing out against resistance, in order to achieve positive expiratory pressure (PEP), is applied by many patient groups. Pursed lips breathing and a variety of devices can be used to create the resistance giving the increased expiratory pressure. Effects on pulmonary outcomes have been discussed in several publications, but the expected underlying physiology of the effect is seldom discussed. The aim of this article is to describe the purpose, performance, clinical application and underlying physiology of PEP when it is used to increase lung volumes, decrease hyperinflation or improve airway clearance. In clinical practice, the instruction how to use an expiratory resistance is of major importance since it varies. Different breathing patterns during PEP increase or reduce expiratory flow, result in movement of EPP centrally or peripherally and can increase or decrease lung volume. It is therefore necessary to give the right instructions to obtain the desired effects. As the different PEP techniques are being used by diverse patient groups it is not possible to give standard instructions. Based on the information given in this article the instructions have to be adjusted to give the optimal effect. There is no consensus regarding optimal treatment frequency and number of cycles included in each treatment session and must also be individualized. In future research, more precise descriptions are needed about physiological aims and specific instructions of how the treatments have been performed to assure as good treatment quality as possible and to be able to evaluate and compare treatment effects. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Mechanical breath profile of airway pressure release ventilation: the effect on alveolar recruitment and microstrain in acute lung injury.

    Science.gov (United States)

    Kollisch-Singule, Michaela; Emr, Bryanna; Smith, Bradford; Roy, Shreyas; Jain, Sumeet; Satalin, Joshua; Snyder, Kathy; Andrews, Penny; Habashi, Nader; Bates, Jason; Marx, William; Nieman, Gary; Gatto, Louis A

    2014-11-01

    Improper mechanical ventilation settings can exacerbate acute lung injury by causing a secondary ventilator-induced lung injury. It is therefore important to establish the mechanism by which the ventilator induces lung injury to develop protective ventilation strategies. It has been postulated that the mechanism of ventilator-induced lung injury is the result of heterogeneous, elevated strain on the pulmonary parenchyma. Acute lung injury has been associated with increases in whole-lung macrostrain, which is correlated with increased pathology. However, the effect of mechanical ventilation on alveolar microstrain remains unknown. To examine whether the mechanical breath profile of airway pressure release ventilation (APRV), consisting of a prolonged pressure-time profile and brief expiratory release phase, reduces microstrain. In a randomized, nonblinded laboratory animal study, rats were randomized into a controlled mandatory ventilation group (n = 3) and an APRV group (n = 3). Lung injury was induced by polysorbate lavage. A thoracotomy was performed and an in vivo microscope was placed on the lungs to measure alveolar mechanics. In the controlled mandatory ventilation group, multiple levels of positive end-expiratory pressure (PEEP; 5, 10, 16, 20, and 24 cm H2O) were tested. In the APRV group, decreasing durations of expiratory release (time at low pressure [T(low)]) were tested. The T(low) was set to achieve ratios of termination of peak expiratory flow rate (T-PEFR) to peak expiratory flow rate (PEFR) of 10%, 25%, 50%, and 75% (the smaller this ratio is [ie, 10%], the more time the lung is exposed to low pressure during the release phase, which decreases end-expiratory lung volume and potentiates derecruitment). Alveolar perimeters were measured at peak inspiration and end expiration using digital image analysis, and strain was calculated by normalizing the change in alveolar perimeter length to the original length. Macrostrain was measured by volume

  15. Experimental intra-abdominal hypertension influences airway pressure limits for lung protective mechanical ventilation.

    Science.gov (United States)

    Cortes-Puentes, Gustavo A; Cortes-Puentes, Luis A; Adams, Alexander B; Anderson, Christopher P; Marini, John J; Dries, David J

    2013-06-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) may complicate monitoring of pulmonary mechanics owing to their impact on the respiratory system. However, recommendations for mechanical ventilation of patients with IAH/ACS and the interpretation of thoracoabdominal interactions remain unclear. Our study aimed to characterize the influence of elevated intra-abdominal pressure (IAP) and positive end-expiratory pressure (PEEP) on airway plateau pressure (PPLAT) and bladder pressure (PBLAD). Nine deeply anesthetized swine were mechanically ventilated via tracheostomy: volume-controlled mode at tidal volume (VT) of 10 mL/kg, frequency of 15, inspiratory-expiratory ratio of 1:2, and PEEP of 1 and 10 cm H2O (PEEP1 and PEEP10, respectively). A tracheostomy tube was placed in the peritoneal cavity, and IAP levels of 5, 10, 15, 20, and 25 mm Hg were applied, using a continuous positive airway pressure system. At each IAP level, PBLAD and airway pressure measurements were performed during both PEEP1 and PEEP10. PBLAD increased as experimental IAP rose (y = 0.83x + 0.5; R = 0.98; p < 0.001 at PEEP1). Minimal underestimation of IAP by PBLAD was observed (-2.5 ± 0.8 mm Hg at an IAP of 10-25 mm Hg). Applying PEEP10 did not significantly affect the correlation between experimental IAP and PBLAD. Approximately 50% of the PBLAD (in cm H2O) was reflected by changes in PPLAT, regardless of the PEEP level applied. Increasing IAP did not influence hemodynamics at any level of IAP generated. With minimal underestimation, PBLAD measurements closely correlated with experimentally regulated IAP, independent of the PEEP level applied. For each PEEP level applied, a constant proportion (approximately 50%) of measured PBLAD (in cm H2O) was reflected in PPLAT. A higher safety threshold for PPLAT should be considered in the setting of IAH/ACS as the clinician considers changes in VT. A strategy of reducing VT to cap PPLAT at widely recommended values may not be

  16. Efeitos da compressão torácica manual versus a manobra de PEEP-ZEEP na complacência do sistema respiratório e na oxigenação de pacientes submetidos à ventilação mecânica invasiva Effects of manual rib-cage compression versus PEEP-ZEEP maneuver on respiratory system compliance and oxygenation in patients receiving mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Flavio Renato Antunes dos Santos

    2009-06-01

    effects of manual rib-cage compression versus the positive end expiratory pressure-zero end expiratory pressure (PEEP-ZEEP maneuver, on compliance of the respiratory system and oxygenation in patients under invasive mechanical ventilation. METHODS: A double centric, prospective, randomized and crossover study, with patients under invasive mechanical ventilation, in controlled mode for more than 48 hours was carried out. The protocols of chest physiothe-rapy were randomly applied at an interval of 24 hours. Data of respiratory system compliance and oxygenation were collected before application of the protocols and 30 minutes after. RESULTS: Twelve patients completed the study. Intragroup analysis, for both techniques showed a statistically significant difference in tidal volume (p=0.002, static compliance (p=0.002 and dynamic compliance (p=0.002. In relation to oxygenation, in the group of manual rib-cage compression, peripheral oxygen saturation increased with a significant difference (p=0.011. CONCLUSIONS: Manual rib-cage compression and PEEP-ZEEP maneuver have positive clinical effects. In relation to oxygenation we found a favorable behavior of peripheral oxygen saturation in the group of manual rib-cage compression.

  17. Rationale and study design of PROVHILO - a worldwide multicenter randomized controlled trial on protective ventilation during general anesthesia for open abdominal surgery

    Directory of Open Access Journals (Sweden)

    Hedenstierna Göran

    2011-05-01

    Full Text Available Abstract Background Post-operative pulmonary complications add to the morbidity and mortality of surgical patients, in particular after general anesthesia >2 hours for abdominal surgery. Whether a protective mechanical ventilation strategy with higher levels of positive end-expiratory pressure (PEEP and repeated recruitment maneuvers; the "open lung strategy", protects against post-operative pulmonary complications is uncertain. The present study aims at comparing a protective mechanical ventilation strategy with a conventional mechanical ventilation strategy during general anesthesia for abdominal non-laparoscopic surgery. Methods The PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure ("PROVHILO" trial is a worldwide investigator-initiated multicenter randomized controlled two-arm study. Nine hundred patients scheduled for non-laparoscopic abdominal surgery at high or intermediate risk for post-operative pulmonary complications are randomized to mechanical ventilation with the level of PEEP at 12 cmH2O with recruitment maneuvers (the lung-protective strategy or mechanical ventilation with the level of PEEP at maximum 2 cmH2O without recruitment maneuvers (the conventional strategy. The primary endpoint is any post-operative pulmonary complication. Discussion The PROVHILO trial is the first randomized controlled trial powered to investigate whether an open lung mechanical ventilation strategy in short-term mechanical ventilation prevents against postoperative pulmonary complications. Trial registration ISRCTN: ISRCTN70332574

  18. Sustained Aeration of Infant Lungs (SAIL) trial: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Foglia, Elizabeth E; Owen, Louise S; Thio, Marta; Ratcliffe, Sarah J; Lista, Gianluca; Te Pas, Arjan; Hummler, Helmut; Nadkarni, Vinay; Ades, Anne; Posencheg, Michael; Keszler, Martin; Davis, Peter; Kirpalani, Haresh

    2015-03-15

    Extremely preterm infants require assistance recruiting the lung to establish a functional residual capacity after birth. Sustained inflation (SI) combined with positive end expiratory pressure (PEEP) may be a superior method of aerating the lung compared with intermittent positive pressure ventilation (IPPV) with PEEP in extremely preterm infants. The Sustained Aeration of Infant Lungs (SAIL) trial was designed to study this question. This multisite prospective randomized controlled unblinded trial will recruit 600 infants of 23 to 26 weeks gestational age who require respiratory support at birth. Infants in both arms will be treated with PEEP 5 to 7 cm H2O throughout the resuscitation. The study intervention consists of performing an initial SI (20 cm H20 for 15 seconds) followed by a second SI (25 cm H2O for 15 seconds), and then PEEP with or without IPPV, as needed. The control group will be treated with initial IPPV with PEEP. The primary outcome is the combined endpoint of bronchopulmonary dysplasia or death at 36 weeks post-menstrual age. www.clinicaltrials.gov , Trial identifier NCT02139800 , Registered 13 May 2014.

  19. Association between driving pressure and development of postoperative pulmonary complications in patients undergoing mechanical ventilation for general anaesthesia: a meta-analysis of individual patient data.

    Science.gov (United States)

    Neto, Ary Serpa; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; El-Tahan, Mohamed R; Ghamdi, Abdulmohsin A Al; Günay, Ersin; Jaber, Samir; Kokulu, Serdar; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Maslow, Andrew D; Memtsoudis, Stavros G; Reis Miranda, Dinis; Moine, Pierre; Ng, Thomas; Paparella, Domenico; Ranieri, V Marco; Scavonetto, Federica; Schilling, Thomas; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; Amato, Marcelo B P; Costa, Eduardo L V; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2016-04-01

    Protective mechanical ventilation strategies using low tidal volume or high levels of positive end-expiratory pressure (PEEP) improve outcomes for patients who have had surgery. The role of the driving pressure, which is the difference between the plateau pressure and the level of positive end-expiratory pressure is not known. We investigated the association of tidal volume, the level of PEEP, and driving pressure during intraoperative ventilation with the development of postoperative pulmonary complications. We did a meta-analysis of individual patient data from randomised controlled trials of protective ventilation during general anesthaesia for surgery published up to July 30, 2015. The main outcome was development of postoperative pulmonary complications (postoperative lung injury, pulmonary infection, or barotrauma). We included data from 17 randomised controlled trials, including 2250 patients. Multivariate analysis suggested that driving pressure was associated with the development of postoperative pulmonary complications (odds ratio [OR] for one unit increase of driving pressure 1·16, 95% CI 1·13-1·19; pprotective ventilation on development of pulmonary complications (p=0·027). In two studies that compared low with high PEEP during low tidal volume ventilation, an increase in the level of PEEP that resulted in an increase in driving pressure was associated with more postoperative pulmonary complications (OR 3·11, 95% CI 1·39-6·96; p=0·006). In patients having surgery, intraoperative high driving pressure and changes in the level of PEEP that result in an increase of driving pressure are associated with more postoperative pulmonary complications. However, a randomised controlled trial comparing ventilation based on driving pressure with usual care is needed to confirm these findings. None. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Is increased positive end-expiratory pressure the culprit? Autoresuscitation in a 44-year-old man after prolonged cardiopulmonary resuscitation: a case report.

    Science.gov (United States)

    Hagmann, Henning; Oelmann, Katrin; Stangl, Robert; Michels, Guido

    2016-12-20

    The phenomenon of autoresuscitation is rare, yet it is known to most emergency physicians. However, the pathophysiology of the delayed return of spontaneous circulation remains enigmatic. Among other causes hyperinflation of the lungs and excessively high positive end-expiratory pressure have been suggested, but reports including cardiopulmonary monitoring during cardiopulmonary resuscitation are scarce to support this hypothesis. We report a case of autoresuscitation in a 44-year-old white man after 80 minutes of advanced cardiac life support accompanied by continuous capnometry and repeated evaluation by ultrasound and echocardiography. After prolonged cardiopulmonary resuscitation, refractory electromechanical dissociation on electrocardiogram and ventricular akinesis were recorded. In addition, a precipitous drop in end-tidal partial pressure of carbon dioxide was noted and cardiopulmonary resuscitation was discontinued. Five minutes after withdrawal of all supportive measures his breathing resumed and a perfusing rhythm ensued. Understanding the underlying pathophysiology of autoresuscitation is hampered by a lack of reports including extensive cardiopulmonary monitoring during cardiopulmonary resuscitation in a preclinical setting. In this case, continuous capnometry was combined with repetitive ultrasound evaluation, which ruled out most assumed causes of autoresuscitation. Our observation of a rapid decline in end-tidal partial pressure of carbon dioxide supports the hypothesis of increased intrathoracic pressure. Continuous capnometry can be performed easily during cardiopulmonary resuscitation, also in a preclinical setting. Knowledge of the pathophysiologic mechanisms may lead to facile interventions to be incorporated into cardiopulmonary resuscitation algorithms. A drop in end-tidal partial pressure of carbon dioxide, for example, might prompt disconnection of the ventilation to allow left ventricular filling. Further reports and research on this topic

  1. Short-term effects of positive expiratory airway pressure in patients being weaned from mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Marcelo de Mello Rieder

    2009-05-01

    Full Text Available OBJECTIVE: To investigate the feasibility and the cardiorespiratory effects of using positive expiratory airway pressure, a physiotherapeutic tool, in comparison with a T-tube, to wean patients from mechanical ventilation. METHODS/DESIGN: A prospective, randomized, cross-over study. SETTING: Two intensive care units. PATIENTS AND INTERVENTIONS: We evaluated forty patients who met weaning criteria and had been mechanically-ventilated for more than 48 hours, mean age 59 years, including 23 males. All patients were submitted to the T-tube and Expiratory Positive Airway Pressure devices, at 7 cm H2O, during a 30-minute period. Cardiorespiratory variables including work of breathing, respiratory rate (rr, peripheral oxygen saturation (SpO2, heart rate (hr, systolic, diastolic and mean arterial pressures (SAP, DAP, MAP were measured in the first and thirtieth minutes. The condition was analyzed as an entire sample set (n=40 and was also divided into subconditions: chronic obstructive pulmonary disease (n=14 and non-chronic obstructive pulmonary disease (non- chronic obstructive pulmonary disease (n=26 categories. Comparisons were made using a t-test and Analysis of Variance. The level of significance was p < 0.05. RESULTS: Our data showed an increase in work of breathing in the first and thirtieth minutes in the EPAP condition (0.86+ 0.43 and 1.02+1.3 as compared with the T-tube condition (0.25+0.26 and 0.26+0.35 (p<0.05, verified by the flow-sensor monitor (values in J/L. No statistical differences were observed when comparing the Expiratory Positive Airway Pressure and T-tube conditions with regard to cardiorespiratory measurements. The same result was observed for both chronic obstructive pulmonary disease and non- chronic obstructive pulmonary disease subconditions. CONCLUSIONS: Our study demonstrated that, in weaning patients from mechanical ventilation, the use of a fixed level of Expiratory Positive Airway Pressure caused an increase in work of

  2. Evaluation of right and left ventricular function during adult respiratory distress syndrom using radionuclide angiocardiography conventional and tomographic approaches

    International Nuclear Information System (INIS)

    Devaux, J.Y.; Dhainaut, J.F.; Roucayrol, J.C.; Brunol, J.

    1982-01-01

    Despite numerous experimental and clinical studies, the cardiovascular effects of mechanical ventilation with positive-end-expiratory pressure (PEEP) are unclear. Specially, the constant fall in cardiac output is not well undestood. The purpose of this study was to investigate the effects of PEEP on right and left ventricular systolic and diastolic performance before and after volume expansion using angioscintigraphy with red blood cells, in vitro labelled with 99m Tc, a reliable, non invasive method to assess right and left ventricular dimensions and global and segmental contractility. First results in patients with adult respiratory distress syndrom (ARDS) confirm the capabilities of such a method for evaluation of regional wall motion in both ventricles

  3. [Lung protective ventilation. Ventilatory modes and ventilator parameters].

    Science.gov (United States)

    Schädler, Dirk; Weiler, Norbert

    2008-06-01

    Mechanical ventilation has a considerable potential for injuring the lung tissue. Therefore, attention has to be paid to the proper choice of ventilatory mode and settings to secure lung-protective ventilation whenever possible. Such ventilator strategy should account for low tidal volume ventilation (6 ml/kg PBW), limited plateau pressure (30 to 35 cm H2O) and positive end-expiratory pressure (PEEP). It is unclear whether pressure controlled or volume controlled ventilation with square flow profile is beneficial. The adjustment of inspiration and expiration time should consider the actual breathing mechanics and anticipate the generation of intrinsic PEEP. Ventilatory modes with the possibility of supporting spontaneous breathing should be used as soon as possible.

  4. Comparison of changes in tidal volume associated with expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation.

    Science.gov (United States)

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-07-01

    [Purpose] This study was designed to compare and clarify the relationship between expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation, with a focus on tidal volume. [Subjects and Methods] The subjects were 18 patients on prolonged mechanical ventilation, who had undergone tracheostomy. Each patient received expiratory rib cage compression and expiratory abdominal compression; the order of implementation was randomized. Subjects were positioned in a 30° lateral recumbent position, and a 2-kgf compression was applied. For expiratory rib cage compression, the rib cage was compressed unilaterally; for expiratory abdominal compression, the area directly above the navel was compressed. Tidal volume values were the actual measured values divided by body weight. [Results] Tidal volume values were as follows: at rest, 7.2 ± 1.7 mL/kg; during expiratory rib cage compression, 8.3 ± 2.1 mL/kg; during expiratory abdominal compression, 9.1 ± 2.2 mL/kg. There was a significant difference between the tidal volume during expiratory abdominal compression and that at rest. The tidal volume in expiratory rib cage compression was strongly correlated with that in expiratory abdominal compression. [Conclusion] These results indicate that expiratory abdominal compression may be an effective alternative to the manual breathing assist procedure.

  5. A Recruiting Maneuver Algorithm in Patients with Early Acute Respiratory Distress Syndrome

    Directory of Open Access Journals (Sweden)

    D. I. Levikov

    2011-01-01

    Full Text Available Objective: to evaluate the efficiency of a recruiting maneuver (RM and adjustment of positive end-expiratory pressure (PEEP in patients with early acute respiratory distress syndrome (ARDS. Subjects and methods. The study enrolled 16 patients (14 men and 2 women aged 46 to 78 years (range 62±5.6 years with ARDS of various genesis. RM was made, by stepwisely increasing PEEP and inspiratory pressure under the control of dynamic lung compliance and hemodynamic parameters. The values of blood gas composition and hemodynamics were determined during the study. Results. RM caused an increase in oxygenation index (OI from 153.5±48.3 to 348.5±53.2 mm Hg. Oxygenation values returned to the baseline levels 30—40 min after the PEEP was set at the closure point of +2 cm H2O. If the set PEEP was 8—10 cm H2O higher than the objective, the effect of RM was retained for as long as 24 hours. When RM was performed using the maximum pressure of 50—60 cm H2O, the cardiac index (CI was lower in all the patients and 30—50% of the baseline values were achieved in all cases, which required the optimization of cardiotonic therapy. The time of this pronounced reduction in cardiac output with RM was not longer than 5 min. After RM, during mechanical ventilation with 18—26 cm H2O PEEP, the CI did not practically differ from the baseline values (3.31±0.41 and 3.37±0.36 l/min/m2, respectively, though the dopamine dose required to maintain normal hemodynamics was somewhat higher (7.5±2.3 and 6.3±2.6 ^g/kg/min. Conclusion. Analysis of the given cases suggests that RM is highly effective in patients at the early stages of acute lung injury. The duration of RM effects may depend on the set PEEP level in individual cases. Setting PEEP at a level of +2—4 cm H2O fails to prevent repeated alveolar derecruitment in a number of patients. In these cases, it is expedient to individually adjust PEEP levels, by taking into account the long-term changes in OI and Cdyn. In

  6. Ventilator-driven xenon ventilation studies

    International Nuclear Information System (INIS)

    Chilcoat, R.T.; Thomas, F.D.; Gerson, J.I.

    1984-01-01

    A modification of a common commercial Xe-133 ventilation device is described for mechanically assisted ventilation imaging. The patient's standard ventilator serves as the power source controlling the ventilatory rate and volume during the xenon study, but the gases in the two systems are not intermixed. This avoids contamination of the ventilator with radioactive xenon. Supplemental oxygen and positive end-expiratory pressure (PEEP) are provided if needed. The system can be converted quickly for conventional studies with spontaneous respiration

  7. Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment.

    Science.gov (United States)

    Spadaro, Savino; Mauri, Tommaso; Böhm, Stephan H; Scaramuzzo, Gaetano; Turrini, Cecilia; Waldmann, Andreas D; Ragazzi, Riccardo; Pesenti, Antonio; Volta, Carlo Alberto

    2018-01-31

    Assessing alveolar recruitment at different positive end-expiratory pressure (PEEP) levels is a major clinical and research interest because protective ventilation implies opening the lung without inducing overdistention. The pressure-volume (P-V) curve is a validated method of assessing recruitment but reflects global characteristics, and changes at the regional level may remain undetected. The aim of the present study was to compare, in intubated patients with acute hypoxemic respiratory failure (AHRF) and acute respiratory distress syndrome (ARDS), lung recruitment measured by P-V curve analysis, with dynamic changes in poorly ventilated units of the dorsal lung (dependent silent spaces [DSSs]) assessed by electrical impedance tomography (EIT). We hypothesized that DSSs might represent a dynamic bedside measure of recruitment. We carried out a prospective interventional study of 14 patients with AHRF and ARDS admitted to the intensive care unit undergoing mechanical ventilation. Each patient underwent an incremental/decremental PEEP trial that included five consecutive phases: PEEP 5 and 10 cmH 2 O, recruitment maneuver + PEEP 15 cmH 2 O, then PEEP 10 and 5 cmH 2 O again. We measured, at the end of each phase, recruitment from previous PEEP using the P-V curve method, and changes in DSS were continuously monitored by EIT. PEEP changes induced alveolar recruitment as assessed by the P-V curve method and changes in the amount of DSS (p Recruited volume measured by the P-V curves significantly correlated with the change in DSS (r s  = 0.734, p recruitment measured using the P-V curve technique. EIT might provide useful information to titrate personalized PEEP. ClinicalTrials.gov, NCT02907840 . Registered on 20 September 2016.

  8. Obesity does not influence the onset and offset of sevoflurane effect as measured by the hysteresis between sevoflurane concentration and bispectral index.

    Science.gov (United States)

    Cortínez, Luis I; Gambús, Pedro; Trocóniz, Iñaki F; Echevarría, Ghislaine; Muñoz, Hernán R

    2011-07-01

    The onset and offset of action of anesthetic gases might be delayed by respiratory changes and gas exchange alterations present in obese patients. In this study, we assessed the influence of obesity on the hysteresis between sevoflurane and its effect as measured by the bispectral index (BIS). Because the use of positive end-expiratory pressure (PEEP) in obese patients has improved gas exchange, we also assessed the influence of PEEP on hysteresis. Fifteen obese and 15 normal-weight patients, ASA physical status I and II, 20 to 50 years old, scheduled to undergo general anesthesia for elective laparoscopic surgery, were prospectively studied. Anesthesia was induced with propofol and maintained with sevoflurane and fentanyl. At the end of surgery and after stable BIS values of 60 to 65, the inspired concentration of sevoflurane was increased to 5 vol% for 5 minutes or until BIS was rate constant was not influenced by body mass index or PEEP (P > 0.05). Neither obesity nor PEEP showed any influence on the PK/PD descriptors. Our results do not support the hypothesis that obesity prolongs induction or recovery times when sevoflurane, a poorly soluble anesthetic, is used to maintain anesthesia from 90 to 120 minutes.

  9. T-piece resuscitators: how do they compare?

    Science.gov (United States)

    Hinder, Murray; McEwan, Alistair; Drevhammer, Thomas; Donaldson, Snorri; Tracy, Mark Brian

    2018-05-04

    The T-piece resuscitator (TPR) has seen increased use as a primary resuscitation device with newborns. Traditional TPR design uses a high resistance expiratory valve to produce positive end expiratory pressure (PEEP) or continuous positive airway pressure (CPAP) at resuscitation. A new TPR device that uses a dual flow ratio valve (fluidic flip) to produce PEEP/CPAP is now available (rPAP). We aimed to compare the measured ventilation performance of different TPR devices in a controlled bench test study. Single operator provided positive pressure ventilation to an incremental testlung compliance (Crs) model (0.5-5 mL/cmH 2 O) with five different brands of TPR device (Atom, Neopuff, rPAP, GE Panda warmer and Draeger Resuscitaire). At recommended peak inflation pressure (PIP) 20 cmH 2 O, PEEP of 5 cmH 2 O and rate of 60 inflations per minute. 1864 inflations were analysed. Four of the five devices tested demonstrated inadvertent elevations in mean PEEP (5.5-10.3 cmH 2 O, p<0.001) from set value as Crs was increased, while one device (rPAP) remained at the set value. Measured PIP exceeded the set value in two infant warmer devices (GE and Draeger) with inbuilt TPR at Crs of 0.5 (24.5 and 23.5 cmH 2 O, p<0.001). Significant differences were seen in tidal volumes across devices particularly at higher Crs (p<0.001). Results show important variation in delivered ventilation from set values due to inherent TPR device design characteristics with a range of lung compliances expected at birth. Device-generated inadvertent PEEP and overdelivery of PIP may be clinically deleterious for term and preterm newborns or infants with larger Crs during resuscitation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. A Dedicated Z-Stent for Acquired Saber-Sheath Tracheobronchomalacia

    International Nuclear Information System (INIS)

    Kishi, Kazushi; Fujimoto, Hisashi Kobayashi; Sonomura, Tetsuo; Uetani, Kosaku; Nishida, Norifumi; Ohata, Masahiro; Sato, Morio; Yamada, Ryusaku

    1997-01-01

    The tracheobronchial lumen has a continuous horseshoe arch morphology. We formed Z-stents accordingly to support the weakened cartilagenous portions. With this type of stent we treated a patient with acquired saber-sheath type tracheobronchomalacia (TBM), Rayl's type II, Johnson's grade III, whose condition was aggravated even under positive end expiratory pressure (PEEP) therapy. The patient improved gradually. No immediate complication was observed. Bronchofiberscopic examination revealed that the tracheobronchial arcade was closely strut-braced and showed no expiratory collapse. Six months later, when the patient was intubated due to asthmatic attacks, tissue ingrowth through the stent was found and removed. There was no recurrence of TBM. The patient died 2 years later of pneumoconiosis

  11. Peep Vain - koolitaja või vaid õhumüüja? / Siim Saidla

    Index Scriptorium Estoniae

    Saidla, Siim, 1981-

    2002-01-01

    Koolitusfirma Vain SMD juhatuse esimehest ja omanikust Peep Vainust räägivad tema koolitustel osalenud. Lisad: Peep Vainu CV; "Kui täna oleks 6. septembri hommik, siis teeksin teisiti" - katkendid Peep Vainu intervjuust iseendaga. Kommenteerivad Mare Pork ja Aune Past

  12. Modes of mechanical ventilation for the operating room.

    Science.gov (United States)

    Ball, Lorenzo; Dameri, Maddalena; Pelosi, Paolo

    2015-09-01

    Most patients undergoing surgical procedures need to be mechanically ventilated, because of the impact of several drugs administered at induction and during maintenance of general anaesthesia on respiratory function. Optimization of intraoperative mechanical ventilation can reduce the incidence of post-operative pulmonary complications and improve the patient's outcome. Preoxygenation at induction of general anaesthesia prolongs the time window for safe intubation, reducing the risk of hypoxia and overweighs the potential risk of reabsorption atelectasis. Non-invasive positive pressure ventilation delivered through different interfaces should be considered at the induction of anaesthesia morbidly obese patients. Anaesthesia ventilators are becoming increasingly sophisticated, integrating many functions that were once exclusive to intensive care. Modern anaesthesia machines provide high performances in delivering the desired volumes and pressures accurately and precisely, including assisted ventilation modes. Therefore, the physicians should be familiar with the potential and pitfalls of the most commonly used intraoperative ventilation modes: volume-controlled, pressure-controlled, dual-controlled and assisted ventilation. Although there is no clear evidence to support the advantage of any one of these ventilation modes over the others, protective mechanical ventilation with low tidal volume and low levels of positive end-expiratory pressure (PEEP) should be considered in patients undergoing surgery. The target tidal volume should be calculated based on the predicted or ideal body weight rather than on the actual body weight. To optimize ventilation monitoring, anaesthesia machines should include end-inspiratory and end-expiratory pause as well as flow-volume loop curves. The routine administration of high PEEP levels should be avoided, as this may lead to haemodynamic impairment and fluid overload. Higher PEEP might be considered during surgery longer than 3 h

  13. Cardiac output estimation using pulmonary mechanics in mechanically ventilated patients

    Directory of Open Access Journals (Sweden)

    Hann Christopher E

    2010-11-01

    Full Text Available Abstract The application of positive end expiratory pressure (PEEP in mechanically ventilated (MV patients with acute respiratory distress syndrome (ARDS decreases cardiac output (CO. Accurate measurement of CO is highly invasive and is not ideal for all MV critically ill patients. However, the link between the PEEP used in MV, and CO provides an opportunity to assess CO via MV therapy and other existing measurements, creating a CO measure without further invasiveness. This paper examines combining models of diffusion resistance and lung mechanics, to help predict CO changes due to PEEP. The CO estimator uses an initial measurement of pulmonary shunt, and estimations of shunt changes due to PEEP to predict CO at different levels of PEEP. Inputs to the cardiac model are the PV loops from the ventilator, as well as the oxygen saturation values using known respiratory inspired oxygen content. The outputs are estimates of pulmonary shunt and CO changes due to changes in applied PEEP. Data from two published studies are used to assess and initially validate this model. The model shows the effect on oxygenation due to decreased CO and decreased shunt, resulting from increased PEEP. It concludes that there is a trade off on oxygenation parameters. More clinically importantly, the model also examines how the rate of CO drop with increased PEEP can be used as a method to determine optimal PEEP, which may be used to optimise MV therapy with respect to the gas exchange achieved, as well as accounting for the impact on the cardiovascular system and its management.

  14. A Case of Shunting Postoperative Patent Foramen Ovale Under Mechanical Ventilation Controlled by Different Ventilator Settings.

    Science.gov (United States)

    Pragliola, Claudio; Di Michele, Sara; Galzerano, Domenico

    2017-06-07

    A 56-year old male with ischemic heart disease and an unremarkable preoperative echocardiogram underwent surgical coronary revascularization. An intraoperative post pump trans-esophageal echocardiogram (TOE) performed while the patient was being ventilated at a positive end expiratory pressure (PEEP) of 8 cm H 2 O demonstrated a right to left interatrial shunt across a patent foramen ovale (PFO). Whereas oxygen saturation was normal, a reduction of the PEEP to 3 cm H 2 O led to the complete resolution of the shunt with no change in arterial blood gases. Attempts to increase the PEEP level above 3 mmHg resulted in recurrence of the interatrial shunt. The remaining of the TEE was unremarkable. Mechanical ventilation, particularly with PEEP, causes an increase in intrathoracic pressure. The resulting rise in right atrial pressure, mostly during inspiration, may unveil and pop open an unrecognized PFO, thus provoking a right to left shunt across a seemingly intact interatrial septum. This phenomenon increases the risk of paradoxical embolism and can lead to hypoxemia. The immediate management would be to adjust the ventilatory settings to a lower PEEP level. A routine search for a PFO should be performed in ventilated patients who undergo a TEE.

  15. A case of shunting postoperative patent foramen ovale under mechanical ventilation controlled by different ventilator settings

    Directory of Open Access Journals (Sweden)

    Claudio Pragliola

    2017-08-01

    Full Text Available A 56-year old male with ischemic heart disease and an unremarkable preoperative echocardiogram underwent surgical coronary revascularization. An intraoperative post pump trans-esophageal echocardiogram (TOE performed while the patient was being ventilated at a positive end expiratory pressure (PEEP of 8 cm H2O demonstrated a right to left interatrial shunt across a patent foramen ovale (PFO. Whereas oxygen saturation was normal, a reduction of the PEEP to 3 cm H2O led to the complete resolution of the shunt with no change in arterial blood gases. Attempts to increase the PEEP level above 3 mmHg resulted in recurrence of the interatrial shunt. The remaining of the TEE was unremarkable. Mechanical ventilation, particularly with PEEP, causes an increase in intrathoracic pressure. The resulting rise in right atrial pressure, mostly during inspiration, may unveil and pop open an unrecognized PFO, thus provoking a right to left shunt across a seemingly intact interatrial septum. This phenomenon increases the risk of paradoxical embolism and can lead to hypoxemia. The immediate management would be to adjust the ventilatory settings to a lower PEEP level. A routine search for a PFO should be performed in ventilated patients who undergo a TEE.

  16. Optimizing PEEP by Electrical Impedance Tomography in a Porcine Animal Model of ARDS.

    Science.gov (United States)

    Hochhausen, Nadine; Biener, Ingeborg; Rossaint, Rolf; Follmann, Andreas; Bleilevens, Christian; Braunschweig, Till; Leonhardt, Steffen; Czaplik, Michael

    2017-03-01

    Mechanical ventilation is necessary in diverse clinical circumstances. Especially in the context of ARDS, so-called protective ventilation strategies must be followed. It is already known that PEEP might enhance oxygenation in ARDS. However, determining the optimal PEEP settings in clinical routines is challenging. Electrical impedance tomography (EIT) is a promising technique with which to adjust ventilator settings. We investigated whether the combination of different EIT parameters, namely the global inhomogeneity and hyperdistension indices, may lead to a feasible and safe PEEP setting. ARDS was induced by a double-hit approach in 18 pigs weighing, on average, 34.8 ± 3.97 kg. First, a surfactant washout was conducted; second, the tidal volume was increased to 20 mL/kg body weight, triggering a ventilator-induced lung injury. Subsequently, pigs were randomized to either the EIT or control groups, followed by an observation time of 24 h. In the control group, PEEP was set according to the ARDS network table. In the EIT group, a PEEP trial was conducted to determine an appropriate PEEP. At defined time points, hemodynamic measures, ventilation parameters, and EIT recordings, as well as blood samples, were taken. After euthanization, lungs were removed for subsequent histopathological and cytological examination. The combination of PEEP and F IO 2 differed between groups, although respiratory compliance, gas exchange, and histopathological examinations, as well as hemodynamics, did not show any statistical differences between the EIT and control groups. However, in the control group, the PEEP/F IO 2 settings followed the given coupling; in the EIT group, divergent individual combinations of PEEP and F IO 2 ranges occurred. PEEP setting by EIT facilitates a more individual ventilation therapy. However, in our relatively short ARDS observation period of 24 h, no significant differences appeared in common clinical parameters compared with a control group. Copyright

  17. Mechanical ventilation strategies for intensive care unit patients without acute lung injury or acute respiratory distress syndrome: a systematic review and network meta-analysis.

    Science.gov (United States)

    Guo, Lei; Wang, Weiwei; Zhao, Nana; Guo, Libo; Chi, Chunjie; Hou, Wei; Wu, Anqi; Tong, Hongshuang; Wang, Yue; Wang, Changsong; Li, Enyou

    2016-07-22

    It has been shown that the application of a lung-protective mechanical ventilation strategy can improve the prognosis of patients with acute lung injury (ALI) or acute respiratory distress syndrome (ARDS). However, the optimal mechanical ventilation strategy for intensive care unit (ICU) patients without ALI or ARDS is uncertain. Therefore, we performed a network meta-analysis to identify the optimal mechanical ventilation strategy for these patients. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library, EMBASE, MEDLINE, CINAHL, and Web of Science for studies published up to July 2015 in which pulmonary compliance or the partial pressure of arterial oxygen/fraction of inspired oxygen (PaO2/FIO2) ratio was assessed in ICU patients without ALI or ARDS, who received mechanical ventilation via different strategies. The data for study characteristics, methods, and outcomes were extracted. We assessed the studies for eligibility, extracted the data, pooled the data, and used a Bayesian fixed-effects model to combine direct comparisons with indirect evidence. Seventeen randomized controlled trials including a total of 575 patients who received one of six ventilation strategies were included for network meta-analysis. Among ICU patients without ALI or ARDS, strategy C (lower tidal volume (VT) + higher positive end-expiratory pressure (PEEP)) resulted in the highest PaO2/FIO2 ratio; strategy B (higher VT + lower PEEP) was associated with the highest pulmonary compliance; strategy A (lower VT + lower PEEP) was associated with a shorter length of ICU stay; and strategy D (lower VT + zero end-expiratory pressure (ZEEP)) was associated with the lowest PaO2/FiO2 ratio and pulmonary compliance. For ICU patients without ALI or ARDS, strategy C (lower VT + higher PEEP) was associated with the highest PaO2/FiO2 ratio. Strategy B (higher VT + lower PEEP) was superior to the other strategies in improving pulmonary

  18. Professor Peep Veski meie meenutustes

    Index Scriptorium Estoniae

    2014-01-01

    Mälestusi Tartu Ülikooli Farmaatsia instituudi juhatajast Peep Veskist jagavad: Eve-Irene Lepist, Urve Paaver, Karin Kogermann, Kristian Semjonov, Jaak Koppel, Kristin Raudsepp, Imre Klebovich, Filiz Hincal, A. Atilla Hincal ja Elmar Arak

  19. Pulmonary edema and lung injury after severe laryngospasm

    International Nuclear Information System (INIS)

    Saddiqi, R.; Khalique, K.

    2006-01-01

    A young male with no pre-operative medical illness underwent corrective surgery for a deviated nasal septum under general anesthesia. At the end of surgery, patient was extubated but went into severe laryngospasm that did not improve with gentle Intermittent Positive Pressure Ventilation (IPPV) and small dose of Suxamethonium. As the situation worsened and patient developed severe bradycardia and de-saturation, re-intubation was done that revealed pink froth in the endotracheal tube. His portable chest X-ray was suggestive of non-cardiogenic pulmonary edema. With an overnight supportive treatment, using mechanical ventilation with Positive End- Expiratory Pressure (PEEP), morphine infusion and frusemide, patient improved and was subsequently weaned off from ventilator. (author)

  20. Effects of a preemptive alveolar recruitment strategy on arterial oxygenation during one-lung ventilation with different tidal volumes in patients with normal pulmonary function test.

    Science.gov (United States)

    Jung, Jong Dal; Kim, Sang Hun; Yu, Byung Sik; Kim, Hye Ji

    2014-08-01

    Hypoxemia during one-lung ventilation (OLV) remains a major concern. The present study compared the effect of alveolar recruitment strategy (ARS) on arterial oxygenation during OLV at varying tidal volumes (Vt) with or without positive end-expiratory pressure (PEEP). In total, 120 patients undergoing wedge resection by video assisted thoracostomy were randomized into four groups comprising 30 patients each: those administered a 10 ml/kg tidal volume with or without preemptive ARS (Group H and Group H-ARS, respectively) and those administered a 6 ml/kg tidal volume and a 8 cmH2O PEEP with or without preemptive ARS (Group L and Group L-ARS, respectively). ARS was performed using pressure-controlled ventilation with a 40 cmH2O plateau airway pressure and a 15 cmH2O PEEP for at least 10 breaths until OLV began. Preemptive ARS significantly improved the PaO2/FiO2 ratio compared to the groups that did not receive ARS (P volume combined with 8 cmH2O PEEP after preemptive ARS may reduce the risk of pulmonary injury caused by high tidal volume during one-lung ventilation in patients with normal pulmonary function.

  1. Spatial distribution of sequential ventilation during mechanical ventilation of the uninjured lung: an argument for cyclical airway collapse and expansion

    Directory of Open Access Journals (Sweden)

    Altemeier William A

    2010-05-01

    Full Text Available Abstract Background Ventilator-induced lung injury (VILI is a recognized complication of mechanical ventilation. Although the specific mechanism by which mechanical ventilation causes lung injury remains an active area of study, the application of positive end expiratory pressure (PEEP reduces its severity. We have previously reported that VILI is spatially heterogeneous with the most severe injury in the dorsal-caudal lung. This regional injury heterogeneity was abolished by the application of PEEP = 8 cm H2O. We hypothesized that the spatial distribution of lung injury correlates with areas in which cyclical airway collapse and recruitment occurs. Methods To test this hypothesis, rabbits were mechanically ventilated in the supine posture, and regional ventilation distribution was measured under four conditions: tidal volumes (VT of 6 and 12 ml/kg with PEEP levels of 0 and 8 cm H2O. Results We found that relative ventilation was sequentially redistributed towards dorsal-caudal lung with increasing tidal volume. This sequential ventilation redistribution was abolished with the addition of PEEP. Conclusions These results suggest that cyclical airway collapse and recruitment is regionally heterogeneous and spatially correlated with areas most susceptible to VILI.

  2. Postural lung recruitment assessed by lung ultrasound in mechanically ventilated children.

    Science.gov (United States)

    Tusman, Gerardo; Acosta, Cecilia M; Böhm, Stephan H; Waldmann, Andreas D; Ferrando, Carlos; Marquez, Manuel Perez; Sipmann, Fernando Suarez

    2017-10-13

    Atelectasis is a common finding in mechanically ventilated children with healthy lungs. This lung collapse cannot be overcome using standard levels of positive end-expiratory pressure (PEEP) and thus for only individualized lung recruitment maneuvers lead to satisfactory therapeutic results. In this short communication, we demonstrate by lung ultrasound images (LUS) the effect of a postural recruitment maneuver (P-RM, i.e., a ventilatory strategy aimed at reaerating atelectasis by changing body position under constant ventilation). Data was collected in the operating room of the Hospital Privado de Comunidad, Mar del Plata, Argentina. Three anesthetized children undergoing mechanical ventilation at constant settings were sequentially subjected to the following two maneuvers: (1) PEEP trial in the supine position PEEP was increased to 10 cmH 2 O for 3 min and then decreased to back to baseline. (2) P-RM patient position was changed from supine to the left and then to the right lateral position for 90 s each before returning to supine. The total P-RM procedure took approximately 3 min. LUS in the supine position showed similar atelectasis before and after the PEEP trial. Contrarily, atelectasis disappeared in the non-dependent lung when patients were placed in the lateral positions. Both lungs remained atelectasis free even after returning to the supine position. We provide LUS images that illustrate the concept and effects of postural recruitment in children. This maneuver has the advantage of achieving recruitment effects without the need to elevate airways pressures.

  3. Within-breath arterial PO2 oscillations in an experimental model of acute respiratory distress syndrome.

    Science.gov (United States)

    Williams, E M; Viale, J P; Hamilton, R M; McPeak, H; Sutton, L; Hahn, C E

    2000-09-01

    Tidal ventilation causes within-breath oscillations in alveolar oxygen concentration, with an amplitude which depends on the prevailing ventilator settings. These alveolar oxygen oscillations are transmitted to arterial oxygen tension, PaO2, but with an amplitude which now depends upon the magnitude of venous admixture or true shunt, QS/QT. We investigated the effect of positive end-expiratory pressure (PEEP) on the amplitude of the PaO2 oscillations, using an atelectasis model of shunt. Blood PaO2 was measured on-line with an intravascular PaO2 sensor, which had a 2-4 s response time (10-90%). The magnitude of the time-varying PaO2 oscillation was titrated against applied PEEP while tidal volume, respiratory rate and inspired oxygen concentration were kept constant. The amplitude of the PaO2 oscillation, delta PaO2, and the mean PaO2 value varied with the level of PEEP applied. At zero PEEP, both the amplitude and the mean were at their lowest values. As PEEP was increased to 1.5 kPa, both delta PaO2 and the mean PaO2 increased to a maximum. Thereafter, the mean PaO2 increased but delta PaO2 decreased. Clear oscillations of PaO2 were seen even at the lowest mean PaO2, 9.5 kPa. Conventional respiratory models of venous admixture predict that these PaO2 oscillations will be reduced by the steep part of the oxyhaemoglobin dissociation curve if a constant pulmonary shunt exists throughout the whole respiratory cycle. The facts that the PaO2 oscillations occurred at all mean PaO2 values and that their amplitude increased with increasing PEEP suggest that QS/QT, in the atelectasis model, varies between end-expiration and end-inspiration, having a much lower value during inspiration than during expiration.

  4. Positive expiratory pressure in patients with chronic obstructive pulmonary disease--a systematic review.

    Science.gov (United States)

    Fagevik Olsén, Monika; Westerdahl, Elisabeth

    2009-01-01

    Breathing exercises against a resistance during expiration are often used as treatment for patients with chronic obstructive pulmonary disease (COPD). Controversy still exists regarding the clinical application and efficacy. The aim of this systematic review was to determine the effects of chest physiotherapy techniques with positive expiratory pressure (PEP) for the prevention and treatment of pulmonary impairment in adults with COPD. The review was conducted on randomised, controlled clinical trials in which breathing exercises with positive expiratory pressure were compared with other chest physical therapy techniques or with no treatment, in adult patients with COPD. A computer-assisted literature search of available databases from 1970 to January 2008 was performed. Two reviewers extracted data independently and assessed the trials systematically with an instrument for measuring methodological quality. In total, 11 trials met the inclusion criteria, of which 5 reached an adequate level of internal validity. Several kinds of PEP techniques with a diversity of intensities and durations of treatment have been evaluated with different outcome measures and follow-up periods. Benefits of PEP were found in isolated outcome measures in separate studies with a follow-up period <1 month. Concerning long-term effects, the results are contradictory. Prior to widespread prescription of long-term PEP treatment, more research is required to establish the benefit of the technique in patients with COPD. (c) 2008 S. Karger AG, Basel.

  5. Anesthetic management of the SRS™ Endoscopic Stapling System for gastro-esophageal reflux disease.

    Science.gov (United States)

    Topuz, Ufuk; Umutoglu, Tarik; Bakan, Mefkur; Ozturk, Erdogan

    2013-01-14

    The SRS(TM) Endoscopic Stapling System (Medigus, Tel Aviv, Israel) is a new tool capable of creating a totally endoscopic fundoplication, combined with an endoscope, endoscopic ultrasound and a surgical stapler. SRS(TM) endoscopic stapling for gastro-esophageal reflux disease is a minimally invasive, outpatient procedure, which requires general anesthesia with positive-pressure ventilation. Keeping the patient on positive end-expiratory pressure (PEEP) may minimize the pressure gradient between the esophagus and the mediastinum, as well as help to prevent air from leaking around the screws and causing pneumomediastinum. In addition, in patients with hiatal hernia, higher PEEP levels may be required to increase intra-thoracic pressure and to force the stomach to slide into the abdomen for ease of endoscopy. We advise smoother emergence from anesthesia, taking precautions for retching, postoperative nausea and vomiting (PONV), while coughing and gagging during extubation and PONV may affect the success of the procedure. Total intravenous anesthesia with propofol and remifentanil seems to be a good choice for these reasons.

  6. Design and Construction of a Microcontroller-Based Ventilator Synchronized with Pulse Oximeter.

    Science.gov (United States)

    Gölcük, Adem; Işık, Hakan; Güler, İnan

    2016-07-01

    This study aims to introduce a novel device with which mechanical ventilator and pulse oximeter work in synchronization. Serial communication technique was used to enable communication between the pulse oximeter and the ventilator. The SpO2 value and the pulse rate read on the pulse oximeter were transmitted to the mechanical ventilator through transmitter (Tx) and receiver (Rx) lines. The fuzzy-logic-based software developed for the mechanical ventilator interprets these values and calculates the percentage of oxygen (FiO2) and Positive End-Expiratory Pressure (PEEP) to be delivered to the patient. The fuzzy-logic-based software was developed to check the changing medical states of patients and to produce new results (FiO2 ve PEEP) according to each new state. FiO2 and PEEP values delivered from the ventilator to the patient can be calculated in this way without requiring any arterial blood gas analysis. Our experiments and the feedbacks from physicians show that this device makes it possible to obtain more successful results when compared to the current practices.

  7. [Effects of recruitment maneuver in prone position on hemodynamics in patients with severe pulmonary infection].

    Science.gov (United States)

    Fan, Yuan-hua; Liu, Yuan-fei; Zhu, Hua-yong; Zhang, Min

    2012-02-01

    To evaluate effects of recruitment maneuver in prone position on hemodynamics in patients with severe pulmonary infection, based on the protective pulmonary ventilation strategy. Ninety-seven cases with severe pulmonary infection admitted to intensive care unit (ICU) of Ganzhou City People's Hospital undergoing mechanical ventilation were involved. Volume controlled ventilation mode with small tidal volume (8 ml/kg) and positive end-expiratory pressure (PEEP) of 6 cm H(2)O [1 cm H(2)O = 0.098 kPa] was conducted. Each patient underwent recruitment maneuver in supine position and then in prone position [PEEP 20 cm H(2)O+pressure control (PC) 20 cm H(2)O]. Heart rate (HR), mean arterial pressure (MAP), pulse oxygen saturation [SpO(2)] and blood gas analysis data were recorded before and after recruitment maneuver in either position. A double-lumen venous catheter was inserted into internal jugular vein or subclavian vein, and a pulse index contour cardiac output (PiCCO) catheter was introduced into femoral artery. Cardiac index (CI), stroke volume index (SVI), systemic vascular resistance index (SVRI), intra-thoracic blood volume index (ITBVI), extra vascular lung water index (EVLWI), global end-diastolic volume index (GEDVI), global ejection fraction (GEF), stroke volume variation (SVV) and central vein pressure (CVP) were monitored. (1) Compared with data before recruitment maneuver, there were no significant differences in HR and MAP after supine position and prone position recruitment maneuver, but significant differences in SpO(2) were found between before and after recruitment maneuver when patients' position was changed (supine position: 0.954 ± 0.032 vs. 0.917 ± 0.025, P recruitment maneuver (P recruitment maneuver, CI [L×min(-1)×m(-2)], SVI (ml/m(2)), GEDVI (ml/m(2)) and GEF were decreased significantly during recruitment maneuver (supine position: CI 3.2 ± 0.4 vs. 3.8 ± 0.6, SVI 32.4 ± 5.6 vs. 38.8 ± 6.5, GEDVI 689 ± 44 vs. 766 ± 32, GEF 0.267 ± 0

  8. Nebulized hypertonic saline via positive expiratory pressure versus via jet nebulizer in patients with severe cystic fibrosis.

    LENUS (Irish Health Repository)

    O'Connell, Oisin J

    2011-06-01

    Nebulized hypertonic saline is a highly effective therapy for patients with cystic fibrosis (CF), yet 10% of patients are intolerant of hypertonic saline administered via jet nebulizer. Positive expiratory pressure (PEP) nebulizers splint open the airways and offers a more controlled rate of nebulization.

  9. Neopuff T-piece resuscitator mask ventilation: Does mask leak vary with different peak inspiratory pressures in a manikin model?

    Science.gov (United States)

    Maheshwari, Rajesh; Tracy, Mark; Hinder, Murray; Wright, Audrey

    2017-08-01

    The aim of this study was to compare mask leak with three different peak inspiratory pressure (PIP) settings during T-piece resuscitator (TPR; Neopuff) mask ventilation on a neonatal manikin model. Participants were neonatal unit staff members. They were instructed to provide mask ventilation with a TPR with three PIP settings (20, 30, 40 cm H 2 O) chosen in a random order. Each episode was for 2 min with 2-min rest period. Flow rate and positive end-expiratory pressure (PEEP) were kept constant. Airway pressure, inspiratory and expiratory tidal volumes, mask leak, respiratory rate and inspiratory time were recorded. Repeated measures analysis of variance was used for statistical analysis. A total of 12 749 inflations delivered by 40 participants were analysed. There were no statistically significant differences (P > 0.05) in the mask leak with the three PIP settings. No statistically significant differences were seen in respiratory rate and inspiratory time with the three PIP settings. There was a significant rise in PEEP as the PIP increased. Failure to achieve the desired PIP was observed especially at the higher settings. In a neonatal manikin model, the mask leak does not vary as a function of the PIP when the flow rate is constant. With a fixed rate and inspiratory time, there seems to be a rise in PEEP with increasing PIP. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  10. Protective versus Conventional Ventilation for Surgery: A Systematic Review and Individual Patient Data Meta-analysis.

    Science.gov (United States)

    Serpa Neto, Ary; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Biehl, Michelle; Binnekade, Jan M; Canet, Jaume; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; Hedenstierna, Göran; Hollmann, Markus W; Jaber, Samir; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Maslow, Andrew D; Memtsoudis, Stavros G; Reis Miranda, Dinis; Moine, Pierre; Ng, Thomas; Paparella, Domenico; Putensen, Christian; Ranieri, Marco; Scavonetto, Federica; Schilling, Thomas; Schmid, Werner; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; Gama de Abreu, Marcelo; Pelosi, Paolo; Schultz, Marcus J

    2015-07-01

    Recent studies show that intraoperative mechanical ventilation using low tidal volumes (VT) can prevent postoperative pulmonary complications (PPCs). The aim of this individual patient data meta-analysis is to evaluate the individual associations between VT size and positive end-expiratory pressure (PEEP) level and occurrence of PPC. Randomized controlled trials comparing protective ventilation (low VT with or without high levels of PEEP) and conventional ventilation (high VT with low PEEP) in patients undergoing general surgery. The primary outcome was development of PPC. Predefined prognostic factors were tested using multivariate logistic regression. Fifteen randomized controlled trials were included (2,127 patients). There were 97 cases of PPC in 1,118 patients (8.7%) assigned to protective ventilation and 148 cases in 1,009 patients (14.7%) assigned to conventional ventilation (adjusted relative risk, 0.64; 95% CI, 0.46 to 0.88; P ventilation with low VT and high PEEP levels and 63 cases in 525 patients (12%) assigned to ventilation with low VT and low PEEP levels (adjusted relative risk, 0.93; 95% CI, 0.64 to 1.37; P = 0.72). A dose-response relationship was found between the appearance of PPC and VT size (R2 = 0.39) but not between the appearance of PPC and PEEP level (R2 = 0.08). These data support the beneficial effects of ventilation with use of low VT in patients undergoing surgery. Further trials are necessary to define the role of intraoperative higher PEEP to prevent PPC during nonopen abdominal surgery.

  11. Peep Vain - the Best-known Training Guru in the Baltics = Peep Vain - Baltikumi tuntuim koolitusguru / Marit Sillavee

    Index Scriptorium Estoniae

    Sillavee, Marit

    2006-01-01

    Koolitusfirma Vain & Partnerid osaniku Peep Vainu karjäärist ja koolitajatööst. Vt. samas: Spiritual Trainer toTop Sportsmen = Tippsportlaste vaimutreener ; Lead Billing in Estonia's Highest-Grossing Documentary = Eesti edukaima dokfilmi peategelane

  12. Evaluation of the Efficiency of Alveolar Opening in Cardiosurgical Patients with Low Left Ventricular Ejection Fraction

    Directory of Open Access Journals (Sweden)

    Yu. G Zorina

    2009-01-01

    Full Text Available Objective: to determine the optimum alveolar opening parameters for the improvement of postoperative pulmonary oxygenizing function in patients with a left ventricular ejection fraction (LVEF of less or more than 40% after aortocoronary bypass surgery (ACBS. Subjects and methods. Twenty patients with a LVEF of less than 40% after ACBS and with postoperative pulmonary oxygenizing dysfunction (PaO2/FiO2 less than 250 (Group 1 were examined. A control group consisted of 20 patients with a LVEF of more than 40% (Group 2. Gas exchange, respiration biomechanics, and central hemodynamic (CH parameters were monitored (a Vigilance monitor (Edvard LifeScience. Alveolar mobilization was carried out on Drager Evita-2 apparatuses in the BIPAP mode, by taking into account the previous artificial ventilation (AV parameters. The low pressure phase corresponded to the positive end-expiratory pressure (PEEP with volume AV, the high pressure phase was Pplato; the duration of both phases — that of inspiration and expiration (the high pressure phase was inspiration time; the low pressure phase was expiration time. Then the values of Pplato and PEEP were simultaneously increased by 2 cm H2O with a duration of 10 breathing cycles, by continuously monitoring Vt and SaO2 over this interval. By continuously monitoring Vt, a stepwise increase in PEEP and Pplato was continued until there was a Vt reduction or a negative impact of AV on CH. All alveoli were considered to be open when the maximum Vt and SaO2 were achieved. Conclusion. In Group 1 patients with Pinsp of 27—30 cm H2O, PEEP of 10—12 cm H2O, there are increases in PaO2/FiO2 and Cst. In Group 2, the increase of PaO2/FiO2 and Cst is observed with Pinsp of 30—35 cm H2O and PEEP 12—14 cm H2O. With these AV indices, there is an allowable hemodynamic reduction that results in no negative consequences and development of cardiovascular events. After switching to AV in an individually chosen mode, all

  13. Rasked vestlused. Kuidas ma talle seda ütlen / Irene Metsis, Sami Seppänen, Peep Sooman ; intervjueerinud Heli Lehtsaar

    Index Scriptorium Estoniae

    Metsis, Irene

    2009-01-01

    Skanska EMV administratsioonijuhi Irene Metsise, AS-i Elisa Eesti tegevdirektori Sami Seppäneni ja Pindi Kinnisvara juhatuse liikme Peep Soomani soovitused negatiivse sõnumi edastamiseks töötajale. Vt. samas: 4 nõuannet juhile, kuidas end keeruliseks vestluseks ette valmistada

  14. Electrical impedance tomography

    Science.gov (United States)

    Lobo, Beatriz; Hermosa, Cecilia; Abella, Ana

    2018-01-01

    Continuous assessment of respiratory status is one of the cornerstones of modern intensive care unit (ICU) monitoring systems. Electrical impedance tomography (EIT), although with some constraints, may play the lead as a new diagnostic and guiding tool for an adequate optimization of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and of end-expiratory lung volume (EELV) and contribute to titrate positive end-expiratory pressure (PEEP)/tidal volume combinations. It may also quantify gains (recruitment) and losses (overdistention or derecruitment), granting a more realistic evaluation of different ventilator modes or recruitment maneuvers, and helping in the identification of responders and non-responders to such maneuvers. Moreover, EIT also contributes to the management of life-threatening lung diseases such as pneumothorax, and aids in guiding fluid management in the critical care setting. Lastly, assessment of cardiac function and lung perfusion through electrical impedance is on the way. PMID:29430443

  15. High altitude pulmonary edema and exercise at 4,400 meters on Mount McKinley. Effect of expiratory positive airway pressure.

    Science.gov (United States)

    Schoene, R B; Roach, R C; Hackett, P H; Harrison, G; Mills, W J

    1985-03-01

    Breathing against positive expiratory pressure has been used to improve gas exchange in many forms of pulmonary edema, and forced expiration against resistance during exercise has been advocated for climbing at high altitude as a method to optimize performance. To evaluate the effect of expiratory positive airway pressure (EPAP) on climbers with high altitude pulmonary edema (HAPE) and on exercise at high altitude, we studied four climbers with HAPE at rest and 13 healthy climbers during exercise on a bicycle ergometer at 4400 m. We measured minute ventilation (VI, L/min), arterial oxygen saturation (SaO2 percent), end-tidal carbon dioxide (PACO2, mm Hg), respiratory rate (RR), and heart rate (HR) during the last minute of a five minute interval at rest in the climbers with HAPE, and at rest, 300, and 600 kpm/minute workloads on a bicycle ergometer in the healthy subjects. The HAPE subjects demonstrated an increased SaO2 percent, no change in HR or VI, and a decrease in RR on EPAP as compared to control. In normal subjects, SaO2 percent, VI, and heart rate were significantly higher on EPAP 10 cm H2O than 0 cm H2O control (p less than 0.01, 0.01, and 0.05, respectively). The RR and PaCO2 were not significantly different. In summary, EPAP improves gas exchange in HAPE subjects at rest. The EPAP in normal subjects at high altitude resulted in a higher SaO2 percent at the expense of a higher VI and higher HR. These results suggest that the work of breathing is higher and the stroke volume lower on EPAP. The positive pressure mask may be an effective temporizing measure for victims of HAPE who cannot immediately go to a lower altitude.

  16. Common-path Fourier domain optical coherence tomography of irradiated human skin and ventilated isolated rabbit lungs

    Science.gov (United States)

    Popp, A.; Wendel, M.; Knels, L.; Knuschke, P.; Mehner, M.; Koch, T.; Boller, D.; Koch, P.; Koch, E.

    2005-08-01

    A compact common path Fourier domain optical coherence tomography (FD-OCT) system based on a broadband superluminescence diode is used for biomedical imaging. The epidermal thickening of human skin after exposure to ultraviolet radiation is measured to proof the feasibility of FD-OCT for future substitution of invasive biopsies in a long term study on natural UV skin protection. The FD-OCT system is also used for imaging lung parenchyma. FD-OCT images of a formalin fixated lung show the same alveolar structure as scanning electron microscopy images. In the ventilated and blood-free perfused isolated rabbit lung FD-OCT is used for real-time cross-sectional image capture of alveolar mechanics throughout tidal ventilation. The alveolar mechanics changing from alternating recruitment-derecruitment at zero positive end-expiratory pressure (PEEP) to persistent recruitment after applying a PEEP of 5 cm H2O is observed in the OCT images.

  17. Deep breathing exercises with positive expiratory pressure in patients with multiple sclerosis - a randomized controlled trial.

    Science.gov (United States)

    Westerdahl, Elisabeth; Wittrin, Anna; Kånåhols, Margareta; Gunnarsson, Martin; Nilsagård, Ylva

    2016-11-01

    Breathing exercises with positive expiratory pressure are often recommended to patients with advanced neurological deficits, but the potential benefit in multiple sclerosis (MS) patients with mild and moderate symptoms has not yet been investigated in randomized controlled trials. To study the effects of 2 months of home-based breathing exercises for patients with mild to moderate MS on respiratory muscle strength, lung function, and subjective breathing and health status outcomes. Forty-eight patients with MS according to the revised McDonald criteria were enrolled in a randomized controlled trial. Patients performing breathing exercises (n = 23) were compared with a control group (n = 25) performing no breathing exercises. The breathing exercises were performed with a positive expiratory pressure device (10-15 cmH 2 O) and consisted of 30 slow deep breaths performed twice a day for 2 months. Respiratory muscle strength (maximal inspiratory and expiratory pressure at the mouth), spirometry, oxygenation, thoracic excursion, subjective perceptions of breathing and self-reported health status were evaluated before and after the intervention period. Following the intervention, there was a significant difference between the breathing group and the control group regarding the relative change in lung function, favoring the breathing group (vital capacity: P < 0.043; forced vital capacity: P < 0.025). There were no other significant differences between the groups. Breathing exercises may be beneficial in patients with mild to moderate stages of MS. However, the clinical significance needs to be clarified, and it remains to be seen whether a sustainable effect in delaying the development of respiratory dysfunction in MS can be obtained. © 2015 The Authors. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  18. Peep Aaviksoo kukutas EMT-kesksus / Jaan Männik ; interv. Vallo Toomet

    Index Scriptorium Estoniae

    Männik, Jaan, 1945-

    2003-01-01

    EMT nõukogu esimees ja Eesti Telekomi juhatuse esimees Jaan Männik vastab küsimustele, mis on seotud Peep Aaviksoo lahkumisega Eesti Mobiiltelefoni juhi kohalt. Vt. samas: Aaviksoo selgitab lahkumise põhjusi. Peep Aaviksoo kiri. Kommenteerivad Radiolinja Eesti juhatuse esimees Sami Seppänen, Tele2 Eesti juhatuse esimees Üllar Jaaksoo, Ühispanga analüütik Sven Kunsing

  19. Effects of peep on lung injury, pulmonary function, systemic circulation and mortality in animals with uninjured lungs-a systematic review

    NARCIS (Netherlands)

    Algera, Anna Geke; Pisani, Luigi; Chaves, Renato Carneiro de Freitas; Amorim, Thiago Chaves; Cherpanath, Thomas; Determann, Rogier; Dongelmans, Dave A.; Paulus, Frederique; Tuinman, Pieter Roel; Pelosi, Paolo; Gama de Abreu, Marcelo; Schultz, Marcus J.; Serpa Neto, Ary

    2018-01-01

    2O, in the 'high PEEP' or 'PEEP' arms, and in the 'low PEEP' or 'no PEEP' arms, respectively. Definitions used for lung injury were quite diverse, as were other outcome measures. The effects of PEEP, at any level, on lung injury was not straightforward, with some trials showing less injury with

  20. Bench performance of ventilators during simulated paediatric ventilation.

    Science.gov (United States)

    Park, M A J; Freebairn, R C; Gomersall, C D

    2013-05-01

    This study compares the accuracy and capabilities of various ventilators using a paediatric acute respiratory distress syndrome lung model. Various compliance settings and respiratory rate settings were used. The study was done in three parts: tidal volume and FiO2 accuracy; pressure control accuracy and positive end-expiratory pressure (PEEP) accuracy. The parameters set on the ventilator were compared with either or both of the measured parameters by the test lung and the ventilator. The results revealed that none of the ventilators could consistently deliver tidal volumes within 1 ml/kg of the set tidal volume, and the discrepancy between the delivered volume and the volume measured by the ventilator varied greatly. The target tidal volume was 8 ml/kg, but delivered tidal volumes ranged from 3.6-11.4 ml/kg and the volumes measured by the ventilator ranged from 4.1-20.6 ml/kg. All the ventilators maintained pressure within 20% of the set pressure, except one ventilator which delivered pressures of up to 27% higher than the set pressure. Two ventilators maintained PEEP within 10% of the prescribed PEEP. The majority of the readings were also within 10%. However, three ventilators delivered, at times, PEEPs over 20% higher. In conclusion, as lung compliance decreases, especially in paediatric patients, some ventilators perform better than others. This study highlights situations where ventilators may not be able to deliver, nor adequately measure, set tidal volumes, pressure, PEEP or FiO2.

  1. Potential hazard of the Neopuff T-piece resuscitator in the absence of flow limitation.

    LENUS (Irish Health Repository)

    Hawkes, C P

    2012-01-31

    OBJECTIVE: (1) To assess peak inspiratory pressure (PIP), positive end expiratory pressure (PEEP) and maximum pressure relief (P(max)) at different rates of gas flow, when the Neopuff had been set to function at 5 l\\/min. (2) To assess maximum PIP and PEEP at a flow rate of 10 l\\/min with a simulated air leak of 50%. DESIGN: 5 Neopuffs were set to a PIP of 20, PEEP of 5 and P(max) of 30 cm H(2)O at a gas flow of 5 l\\/min. PIP, PEEP and P(max) were recorded at flow rates of 10, 15 l\\/min and maximum flow. Maximum achievable pressures at 10 l\\/min gas flow, with a 50% air leak, were measured. RESULTS: At gas flow of 15 l\\/min, mean PEEP increased to 20 (95% CI 20 to 21), PIP to 28 (95% CI 28 to 29) and the P(max) to 40 cm H(2)O (95% CI 38 to 42). At maximum flow (85 l\\/min) a PEEP of 71 (95% CI 51 to 91) and PIP of 92 cm H(2)O (95% CI 69 to 115) were generated. At 10 l\\/min flow, with an air leak of 50%, the maximum PEEP and PIP were 21 (95% CI 19 to 23) and 69 cm H(2)O (95% CI 66 to 71). CONCLUSIONS: The maximum pressure relief valve is overridden by increasing the rate of gas flow and potentially harmful PIP and PEEP can be generated. Even in the presence of a 50% gas leak, more than adequate pressures can be provided at 10 l\\/min gas flow. We recommend the limitation of gas flow to a rate of 10 l\\/min as an added safety mechanism for this device.

  2. Tidal Volume Delivery and Endotracheal Tube Leak during Cardiopulmonary Resuscitation in Intubated Newborn Piglets with Hypoxic Cardiac Arrest Exposed to Different Modes of Ventilatory Support.

    Science.gov (United States)

    Mendler, Marc R; Weber, Claudia; Hassan, Mohammad A; Huang, Li; Mayer, Benjamin; Hummler, Helmut D

    2017-01-01

    There are few data available on the interaction of inflations, chest compressions (CC), and delivery of tidal volumes in newborn infants undergoing resuscitation in the presence of endotracheal tube (ET) leaks. To determine the effects of different respiratory support strategies along with CC on changes in tidal volume and ET leaks in hypoxic newborn piglets with cardiac arrest. Asphyxiated newborn piglets, intubated with weight-adapted uncuffed ET, were randomized into three groups and resuscitated according to ILCOR 2010 guidelines: (1) T-piece resuscitator (TPR) group = peak inspiratory pressure (PIP)/positive end-expiratory pressure (PEEP) 25/5 cm H2O, rate 30/min, inflations interposed between CC (3:1 ratio); (2) self- inflating bag (SIB) group = PIP 25 cm H2O without PEEP, rate 30/min, inflations interposed between CC (3:1 ratio), and (3) ventilator group = PIP/PEEP of 25/5 cm H2O, rate 30/min. CC were applied with a rate of 120/min without synchrony to inflations. We observed a significant increase of leak (average increase 11.4%) when CC was added to respiratory support (p = 0.0001). Expired tidal volume was larger in the SIB group than in the two other modes which both applied PEEP. However, tidal volumes caused by CC only were larger in the two groups with PEEP than in the SIB group (without PEEP). There is interaction between lung inflations and CC affecting leak and delivery of tidal volume, which may be influenced by the mode/device used for respiratory support. Leak is larger in the presence of PEEP. However, CC cause additional tidal volume which is larger in the presence of PEEP. © 2016 S. Karger AG, Basel.

  3. Lung-Protective Ventilation Strategies for Relief from Ventilator-Associated Lung Injury in Patients Undergoing Craniotomy: A Bicenter Randomized, Parallel, and Controlled Trial

    Directory of Open Access Journals (Sweden)

    Chaoliang Tang

    2017-01-01

    Full Text Available Current evidence indicates that conventional mechanical ventilation often leads to lung inflammatory response and oxidative stress, while lung-protective ventilation (LPV minimizes the risk of ventilator-associated lung injury (VALI. This study evaluated the effects of LPV on relief of pulmonary injury, inflammatory response, and oxidative stress among patients undergoing craniotomy. Sixty patients undergoing craniotomy received either conventional mechanical (12 mL/kg tidal volume [VT] and 0 cm H2O positive end-expiratory pressure [PEEP]; CV group or protective lung (6 mL/kg VT and 10 cm H2O PEEP; PV group ventilation. Hemodynamic variables, lung function indexes, and inflammatory and oxidative stress markers were assessed. The PV group exhibited greater dynamic lung compliance and lower respiratory index than the CV group during surgery (P0.05. Patients receiving LPV during craniotomy exhibited low perioperative inflammatory response, oxidative stress, and VALI.

  4. Mitogen-activated protein kinase phosphatase-1 modulates regional effects of injurious mechanical ventilation in rodent lungs.

    Science.gov (United States)

    Park, Moo Suk; He, Qianbin; Edwards, Michael G; Sergew, Amen; Riches, David W H; Albert, Richard K; Douglas, Ivor S

    2012-07-01

    Mechanical ventilation induces heterogeneous lung injury by mitogen-activated protein kinase (MAPK) and nuclear factor-κB. Mechanisms regulating regional injury and protective effects of prone positioning are unclear. To determine the key regulators of the lung regional protective effects of prone positioning in rodent lungs exposed to injurious ventilation. Adult rats were ventilated with high (18 ml/kg, positive end-expiratory pressure [PEEP] 0) or low Vt (6 ml/kg; PEEP 3 cm H(2)O; 3 h) in supine or prone position. Dorsal-caudal lung mRNA was analyzed by microarray and MAPK phosphatases (MKP)-1 quantitative polymerase chain reaction. MKP-1(-/-) or wild-type mice were ventilated with very high (24 ml/kg; PEEP 0) or low Vt (6-7 ml/kg; PEEP 3 cm H(2)O). The MKP-1 regulator PG490-88 (MRx-108; 0.75 mg/kg) or phosphate-buffered saline was administered preventilation. Injury was assessed by lung mechanics, bronchioalveolar lavage cell counts, protein content, and lung injury scoring. Immunoblotting for MKP-1, and IκBα and cytokine ELISAs were performed on lung lysates. Prone positioning was protective against injurious ventilation in rats. Expression profiling demonstrated MKP-1 20-fold higher in rats ventilated prone rather than supine and regional reduction in p38 and c-jun N-terminal kinase activation. MKP-1(-/-) mice experienced amplified injury. PG490-88 improved static lung compliance and injury scores, reduced bronchioalveolar lavage cell counts and cytokine levels, and induced MKP-1 and IκBα. Injurious ventilation induces MAPK in an MKP-1-dependent fashion. Prone positioning is protective and induces MKP-1. PG490-88 induced MKP-1 and was protective against high Vt in a nuclear factor-κB-dependent manner. MKP-1 is a potential target for modulating regional effects of injurious ventilation.

  5. Pulmonar recruitment in acute respiratory distress syndrome. What is the best strategy?

    Directory of Open Access Journals (Sweden)

    Cíntia Lourenço Santos

    Full Text Available Supporting patients with acute respiratory distress syndrome (ARDS, using a protective mechanical ventilation strategy characterized by low tidal volume and limitation of positive end-expiratory pressure (PEEP is a standard practice in the intensive care unit. However, these strategies can promote lung de-recruitment, leading to the cyclic closing and reopening of collapsed alveoli and small airways. Recruitment maneuvers (RM can be used to augment other methods, like positive end-expiratory pressure and positioning, to improve aerated lung volume. Clinical practice varies widely, and the optimal method and patient selection for recruitment maneuvers have not been determined, considerable uncertainty remaining regarding the appropriateness of RM. This review aims to discuss recent findings about the available types of RM, and compare the effectiveness, indications and adverse effects among them, as well as their impact on morbidity and mortality in ARDS patients. Recent developments include experimental and clinical evidence that a stepwise extended recruitment maneuver may cause an improvement in aerated lung volume and decrease the biological impact seen with the traditionally used sustained inflation, with less adverse effects. Prone positioning can reduce mortality in severe ARDS patients and may be an useful adjunct to recruitment maneuvers and advanced ventilatory strategies, such noisy ventilation and BIVENT, which have been useful in providing lung recruitment.

  6. Improved oxygenation during standing performance of deep breathing exercises with positive expiratory pressure after cardiac surgery: A randomized controlled trial.

    Science.gov (United States)

    Pettersson, Henrik; Faager, Gun; Westerdahl, Elisabeth

    2015-09-01

    Breathing exercises after cardiac surgery are often performed in a sitting position. It is unknown whether oxygenation would be better in the standing position. The aim of this study was to evaluate oxygenation and subjective breathing ability during sitting vs standing performance of deep breathing exercises on the second day after cardiac surgery. Patients undergoing coronary artery bypass grafting (n = 189) were randomized to sitting (controls) or standing. Both groups performed 3 × 10 deep breaths with a positive expiratory pressure device. Peripheral oxygen saturation was measured before, directly after, and 15 min after the intervention. Subjective breathing ability, blood pressure, heart rate, and pain were assessed. Oxygenation improved significantly in the standing group compared with controls directly after the breathing exercises (p < 0.001) and after 15 min rest (p = 0.027). The standing group reported better deep breathing ability compared with controls (p = 0.004). A slightly increased heart rate was found in the standing group (p = 0.047). After cardiac surgery, breathing exercises with positive expiratory pressure, performed in a standing position, significantly improved oxygenation and subjective breathing ability compared with sitting performance. Performance of breathing exercises in the standing position is feasible and could be a valuable treatment for patients with postoperative hypoxaemia.

  7. Cystic Fibrosis: Are Volumetric Ultra-Low-Dose Expiratory CT Scans Sufficient for Monitoring Related Lung Disease?

    DEFF Research Database (Denmark)

    Loeve, Martine; Lequin, Maarten H; Bruijne, Marleen de

    2009-01-01

    Purpose: To assess whether chest computed tomography (CT) scores from ultra-low-dose end-expiratory scans alone could suffice for assessment of all cystic fibrosis (CF)-related structural lung abnormalities. Materials and Methods: In this institutional review board–approved study, 20 patients...... with CF aged 6–20 years (eight males, 12 females) underwent low-dose end-inspiratory CT and ultra-low-dose end-expiratory CT. Informed consent was obtained. Scans were randomized and scored by using the Brody-II CT scoring system to assess bronchiectasis, airway wall thickening, mucus plugging......-Altman plots. Results: Median age was 12.6 years (range, 6.3–20.3 years), median forced expiratory volume in 1 second was 100% (range, 46%–127%) of the predicted value, and median forced vital capacity was 99% (range, 61%–123%) of the predicted value. Very good agreement was observed between end...

  8. Nonassociative learning promotes respiratory entrainment to mechanical ventilation.

    Directory of Open Access Journals (Sweden)

    Shawna M MacDonald

    Full Text Available BACKGROUND: Patient-ventilator synchrony is a major concern in critical care and is influenced by phasic lung-volume feedback control of the respiratory rhythm. Routine clinical application of positive end-expiratory pressure (PEEP introduces a tonic input which, if unopposed, might disrupt respiratory-ventilator entrainment through sustained activation of the vagally-mediated Hering-Breuer reflex. We suggest that this potential adverse effect may be averted by two differentiator forms of nonassociative learning (habituation and desensitization of the Hering-Breuer reflex via pontomedullary pathways. METHODOLOGY/PRINCIPAL FINDINGS: We tested these hypotheses in 17 urethane-anesthetized adult Sprague-Dawley rats under controlled mechanical ventilation. Without PEEP, phrenic discharge was entrained 1:1 to the ventilator rhythm. Application of PEEP momentarily dampened the entrainment to higher ratios but this effect was gradually adapted by nonassociative learning. Bilateral electrolytic lesions of the pneumotaxic center weakened the adaptation to PEEP, whereas sustained stimulation of the pneumotaxic center weakened the entrainment independent of PEEP. In all cases, entrainment was abolished after vagotomy. CONCLUSIONS/SIGNIFICANCE: Our results demonstrate an important functional role for pneumotaxic desensitization and extra-pontine habituation of the Hering-Breuer reflex elicited by lung inflation: acting as buffers or high-pass filters against tonic vagal volume input, these differentiator forms of nonassociative learning help to restore respiratory-ventilator entrainment in the face of PEEP. Such central sites-specific habituation and desensitization of the Hering-Breuer reflex provide a useful experimental model of nonassociative learning in mammals that is of particular significance in understanding respiratory rhythmogenesis and coupled-oscillator entrainment mechanisms, and in the clinical management of mechanical ventilation in

  9. Peep Põldsamm lõi kampa Skype'i loojatega

    Index Scriptorium Estoniae

    2008-01-01

    Peep Põldsamm asus juhtima Modesat Communications OÜd, mille omanik on Skype'i kaasasutajatele kuuluv investeerimisfirma Ambient Sound Investments. Modesat plaanib saavutada modemitehnoloogia rahvusvahelisel turul viieprotsendilise turuosa. Vt. samas: Põldsamm: olen uute äride ülesehitaja

  10. Estimation of lung volume and pulmonary blood volume from radioisotopic images

    International Nuclear Information System (INIS)

    Kanazawa, Minoru

    1989-01-01

    Lung volume and pulmonary blood volume in man were estimated from the radioisotopic image using single photon emission computed tomography (SPECT). Six healthy volunteers were studied in a supine position with normal and altered lung volumes by applying continuous negative body-surface pressure (CNP) and by positive end-expiratory pressure (PEEP). 99m Tc labeled human serum albumin was administered as an aerosol to image the lungs. The CNP caused the diaphragm to be lowered and it increased the mean lung tissue volume obtained by SPECT from 3.09±0.49 l for baseline to 3.67±0.62 l for 10 cmH 2 O (p 2 O (p 2 O), respectively. The PEEP also increased the lung tissue volume to 3.68±0.68 l for 10 cmH 2 O as compared with the baseline (p 2 O PEEP. The lung tissue volume obtained by SPECT showed a positive correlation with functional residual capacity measured by the He dilution method (r=0.91, p 99m Tc-labeled red blood cells. The L/H ratio decreased after either the CNP or PEEP, suggesting a decrease in the blood volume per unit lung volume. However, it was suggested that the total pulmonary blood volume increased slightly either on the CNP (+7.4% for 10 cmH 2 O, p 2 O,p<0.05) when we extrapolated the L/H ratio to the whole lungs by multiplying the lung tissue volume obtained by SPECT. We concluded that SPECT could offer access to the estimation of lung volume and pulmonary blood volume in vivo. (author)

  11. Effects of dorsal and lateral decubitus on peak expiratory flow in healthy subjects

    Directory of Open Access Journals (Sweden)

    Heloisa H. Gianinis

    2013-10-01

    Full Text Available BACKGROUND: One of the measures of the pulmonary function is the peak expiratory flow (PEF that can be defined as the major flow obtained in an expiratory pressure after a complete inspiration to the level of the total lung capacity. This measure depends on the effort and strength of expiratory muscles, the airway diameter and the lung volume. OBJECTIVE: To compare the results of the peak expiratory flow in healthy male and female obtained in a seated position and dorsal decubitus (DD, right lateral decubitus (RLD and left lateral decubitus (LLD. METHOD: Thirty young subjects with mean age 22.7 years, healthy and non-smokers were included at the study, 15 of male sex. They did spirometry and IPAQ questionnaire to check the normal pulmonary function and physical activity level. The measures of PEF were performed in four positions, being performed 3 measures in which position, in a random order. Statistical analysis was performed according to Student's t test, with significance level set at 5%. RESULTS: There was a difference between the values obtained in sitting position(481±117.1 L/min with DD(453.2±116.3 L/min and RLD (454±112.9 L/min (p<0.05, however, did not find a significant difference between the sitting position and LLD (469±83 L/min. CONCLUSIONS: Body position affects the values of PEF, with decreasing values in DD and RLD. The LLD can be an alternative to optimize the expiratory flow in situations of constraint to the sitting position.

  12. Ventilation therapy for patients suffering from obstructive lung diseases.

    Science.gov (United States)

    Jungblut, Sven A; Heidelmann, Lena M; Westerfeld, Andreas; Frickmann, Hagen; Körber, Mareike K; Zautner, Andreas E

    2014-01-01

    Severe bronchial obstruction due to one of the major pulmonary diseases: asthma, COPD, or emphysema often requires mechanical ventilation support. Otherwise, patients are at risk of severe hypooxygenation with consecutive overloading and dilatation of the right cardiac ventricle with subsequent failure. This review focuses on how to manage a calculated ventilation therapy of patients suffering from bronchial obstruction and relevant patents. Options and pitfalls of invasive and non-invasive ventilation in the intensive care setting regarding clinical improvement and final outcome are discussed. The non-invasive ventilation is very efficient in treating acute or chronic respiratory failure in COPD patients and is capable of shortening the duration of hospitalization. Further non-invasive ventilation can successfully support the weaning after a long-lasting ventilation therapy and improve the prognosis of COPD patients. "Permissive hypercapnia" is unequivocally established in invasive ventilation therapy of severe bronchial obstruction in situations of limited ventilation. When intrinsic positive end-expiratory pressure (PEEP) and elevated airways resistance are present PEEP may be useful although external-PEEP application relieves over-inflation only in selected patients with airway obstruction during controlled mechanical ventilation. Upper limit of airways peak pressure used in "protective ventilation" of adult respiratory distress syndrome (ARDS) patients can be exceeded under certain circumstances.

  13. Injurious mechanical ventilation in the normal lung causes a progressive pathologic change in dynamic alveolar mechanics.

    Science.gov (United States)

    Pavone, Lucio A; Albert, Scott; Carney, David; Gatto, Louis A; Halter, Jeffrey M; Nieman, Gary F

    2007-01-01

    Acute respiratory distress syndrome causes a heterogeneous lung injury, and without protective mechanical ventilation a secondary ventilator-induced lung injury can occur. To ventilate noncompliant lung regions, high inflation pressures are required to 'pop open' the injured alveoli. The temporal impact, however, of these elevated pressures on normal alveolar mechanics (that is, the dynamic change in alveolar size and shape during ventilation) is unknown. In the present study we found that ventilating the normal lung with high peak pressure (45 cmH(2)0) and low positive end-expiratory pressure (PEEP of 3 cmH(2)O) did not initially result in altered alveolar mechanics, but alveolar instability developed over time. Anesthetized rats underwent tracheostomy, were placed on pressure control ventilation, and underwent sternotomy. Rats were then assigned to one of three ventilation strategies: control group (n = 3, P control = 14 cmH(2)O, PEEP = 3 cmH(2)O), high pressure/low PEEP group (n = 6, P control = 45 cmH(2)O, PEEP = 3 cmH(2)O), and high pressure/high PEEP group (n = 5, P control = 45 cmH(2)O, PEEP = 10 cmH(2)O). In vivo microscopic footage of subpleural alveolar stability (that is, recruitment/derecruitment) was taken at baseline and than every 15 minutes for 90 minutes following ventilator adjustments. Alveolar recruitment/derecruitment was determined by measuring the area of individual alveoli at peak inspiration (I) and end expiration (E) by computer image analysis. Alveolar recruitment/derecruitment was quantified by the percentage change in alveolar area during tidal ventilation (%I - E Delta). Alveoli were stable in the control group for the entire experiment (low %I - E Delta). Alveoli in the high pressure/low PEEP group were initially stable (low %I - E Delta), but with time alveolar recruitment/derecruitment developed. The development of alveolar instability in the high pressure/low PEEP group was associated with histologic lung injury. A large change in

  14. Role of bronchodilation and pattern of breathing in increasing tidal expiratory flow with progressive induced hypercapnia in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Finucane, Kevin E; Singh, Bhajan

    2018-01-01

    Hypercapnia (HC) in vitro relaxes airway smooth muscle; in vivo, it increases respiratory effort, tidal expiratory flows (V̇ exp ), and, by decreasing inspiratory duration (Ti), increases elastic recoil pressure (Pel) via lung viscoelasticity; however, its effect on airway resistance is uncertain. We examined the contributions of bronchodilation, Ti, and expiratory effort to increasing V̇ exp with progressive HC in 10 subjects with chronic obstructive pulmonary disease (COPD): mean forced expiratory volume in 1 s (FEV 1 ) 53% predicted. Lung volumes (Vl), V̇ exp , esophageal pressure (Pes), Ti, and end-tidal Pco 2 ([Formula: see text]) were measured during six tidal breaths followed by an inspiratory capacity (IC), breathing air, and at three levels of HC. V̇ exp and V̇ with submaximal forced vital capacities breathing air (V̇ sFVC ) were compared. Pulmonary resistance ( Rl) was measured from the Pes-V̇ relationship. V̇ exp and Pes at end-expiratory lung volume (EELV) + 0.3 tidal volume [V̇ (0.3Vt) and Pes (0.3Vt) , respectively], Ti, and Rl correlated with [Formula: see text] ( P pulmonary disease (COPD), progressive HC increases tidal expiratory flows by inducing bronchodilation and via an increased rate of inspiration and lung viscoelasticity, a probable increase in lung elastic recoil pressure, both changes increasing expiratory flows, promoting lung emptying and a stable end-expiratory volume. Bronchodilation with HC occurred despite optimal standard bronchodilator therapy, suggesting that in COPD further bronchodilation is possible.

  15. High positive end-expiratory pressure levels promote bacterial translocation in experimental pneumonia

    NARCIS (Netherlands)

    Lachmann, Robert A.; van Kaam, Anton H.; Haitsma, Jack J.; Lachmann, Burkhard

    2007-01-01

    A previous study in piglets with experimental pneumonia showed that reducing atelectasis by means of open lung ventilation attenuated bacterial translocation compared to conventional ventilation settings. This study examined the effect of open lung ventilation with higher than necessary positive

  16. Feasibility of Protective Ventilation During Elective Supratentorial Neurosurgery: A Randomized, Crossover, Clinical Trial.

    Science.gov (United States)

    Ruggieri, Francesco; Beretta, Luigi; Corno, Laura; Testa, Valentina; Martino, Enrico A; Gemma, Marco

    2017-06-30

    Traditional ventilation approaches, providing high tidal volumes (Vt), produce excessive alveolar distention and lung injury. Protective ventilation, employing lower Vt and positive end-expiratory pressure (PEEP), is an attractive alternative also for neuroanesthesia, when prolonged mechanical ventilation is needed. Nevertheless, protective ventilation during intracranial surgery may exert dangerous effects on intracranial pressure (ICP). We tested the feasibility of a protective ventilation strategy in neurosurgery. Our monocentric, double-blind, 1:1 randomized, 2×2 crossover study aimed at studying the effect size and variability of ICP in patients undergoing elective supratentorial brain tumor removal and alternatively ventilated with Vt 9 mL/kg-PEEP 0 mm Hg and Vt 7 mL/kg-PEEP 5 mm Hg. Respiratory rate was adjusted to maintain comparable end-tidal carbon dioxide between ventilation modes. ICP was measured through a subdural catheter inserted before dural opening. Forty patients were enrolled; 8 (15%) were excluded after enrollment. ICP did not differ between traditional and protective ventilation (11.28±5.37, 11 [7 to 14.5] vs. 11.90±5.86, 11 [8 to 15] mm Hg; P=0.541). End-tidal carbon dioxide (28.91±2.28, 29 [28 to 30] vs. 28.00±2.17, 28 [27 to 29] mm Hg; Pprotective ventilation. Blood pressure, heart rate, and body temperature did not differ between ventilation modes. Dural tension was "acceptable for surgery" in all cases. ICP differences between ventilation modes were not affected by ICP values under traditional ventilation (coefficient=0.067; 95% confidence interval, -0.278 to 0.144; P=0.523). Protective ventilation is a feasible alternative to traditional ventilation during elective neurosurgery.

  17. English for lawyers / Liina Soobik ; [preface: Peep Pruks

    Index Scriptorium Estoniae

    Soobik, Liina, 1955-

    2001-01-01

    Kasutatud tekstide autorid: Peep Pruks, Merit-Ene Ilja, Ilona Nurmela, Kristi Raba, Andreas Kangur, Raul Narits, Peeter Roosma, Kalle Merusk, Maret Altnurme, Jaan Ginter, Aare Tark, Norman Aas, Lasse Lehis, Hannes Veinla, Jaan Sootak, Eerik Kergandberg, Paul Varul, Jaanus Ots, Urve Liin, Irene Kull, Merle Muda, Gaabriel Tavits, Andres Vutt, Kadri Siibak, Ellen Ridaste, Heiki Pisuke, Andrus Siibak

  18. Functional Magnetic Stimulation of Inspiratory and Expiratory Muscles in Subjects With Tetraplegia.

    Science.gov (United States)

    Zhang, Xiaoming; Plow, Ela; Ranganthan, Vinoth; Huang, Honglian; Schmitt, Melissa; Nemunaitis, Gregory; Kelly, Clay; Frost, Frederick; Lin, Vernon

    2016-07-01

    Respiratory complications are major causes of morbidity and mortality in persons with a spinal cord injury, partly because of respiratory muscle paralysis. Earlier investigation has demonstrated that functional magnetic stimulation (FMS) can be used as a noninvasive technology for activating expiratory muscles, thus producing useful expiratory functions (simulated cough) in subjects with spinal cord injury. To evaluate the effectiveness of FMS for conditioning inspiratory and expiratory muscles in persons with tetraplegia. A prospective before and after trial. FMS Laboratory, Louis Stokes Cleveland VA Medical Center, Cleveland, OH. Six persons with tetraplegia. Each subject participated in a 6-week FMS protocol for conditioning the inspiratory and expiratory muscles. A magnetic stimulator was used with the center of a magnetic coil placed at the C7-T1 and T9-T10 spinous processes, respectively. Pulmonary function tests were performed before, during, and after the protocol. Respiratory variables included maximal inspiratory pressure (MIP), inspiratory reserve volume (IRV), peak inspiratory flow (PIF), maximal expiratory pressure (MEP), expiratory reserve volume (ERV), and peak expiratory flow (PEF). After 6 weeks of conditioning, the main outcome measurements (mean ± standard error) were as follows: MIP, 89.6 ± 7.3 cm H2O; IRV, 1.90 ± 0.34 L; PIF, 302.4 ± 36.3 L/min; MEP, 67.4 ± 11.1 cm H2O; ERV, 0.40 ± 0.06 L; and PEF, 372.4 ± 31.9 L/min. These values corresponded to 117%, 107%, 136%, 109%, 130%, and 124% of pre-FMS conditioning values, respectively. Significant improvements were observed in MIP (P = .022), PIF (P = .0001), and PEF (P = .0006), respectively. When FMS was discontinued for 4 weeks, these values showed decreases from their values at the end of the conditioning protocol, which suggests that continual FMS may be necessary to maintain improved respiratory functions. FMS conditioning of the inspiratory and expiratory muscles improved

  19. Influence of tidal volume on ventilation inhomogeneity assessed by electrical impedance tomography during controlled mechanical ventilation

    International Nuclear Information System (INIS)

    Becher, T; Kott, M; Schädler, D; Vogt, B; Meinel, T; Weiler, N; Frerichs, I

    2015-01-01

    The global inhomogeneity (GI) index is a parameter of ventilation inhomogeneity that can be calculated from images of tidal ventilation distribution obtained by electrical impedance tomography (EIT). It has been suggested that the GI index may be useful for individual adjustment of positive end-expiratory pressure (PEEP) and for guidance of ventilator therapy. The aim of the present work was to assess the influence of tidal volume (V_T) on the GI index values. EIT data from 9 patients with acute respiratory distress syndrome ventilated with a low and a high V_T of 5   ±   1 (mean  ±  SD) and 9   ±   1 ml kg"−"1 predicted body weight at a high and a low level of PEEP (PEEP_h_i_g_h, PEEP_l_o_w) were analyzed. PEEP_h_i_g_h and PEEP_l_o_w were set 2 cmH_2O above and 5 cmH_2O below the lower inflection point of a quasi-static pressure volume loop, respectively. The lower inflection point was identified at 8.1   ±   1.4 (mean  ±  SD) cmH_2O, resulting in a PEEP_h_i_g_h of 10.1   ±   1.4 and a PEEP_l_o_w of 3.1   ±   1.4 cmH_2O. At PEEP_h_i_g_h, we found no significant trend in GI index with low V_T when compared to high V_T (0.49   ±   0.15 versus 0.44   ±   0.09, p = 0.13). At PEEP_l_o_w, we found a significantly higher GI index with low V_T compared to high V_T (0.66   ±   0.19 versus 0.59   ±   0.17, p = 0.01). When comparing the PEEP levels, we found a significantly lower GI index at PEEP_h_i_g_h both for high and low V_T. We conclude that high V_T may lead to a lower GI index, especially at low PEEP settings. This should be taken into account when using the GI index for individual adjustment of ventilator settings. (paper)

  20. Respiratory mechanics in infants with severe bronchiolitis on controlled mechanical ventilation.

    Science.gov (United States)

    Cruces, Pablo; González-Dambrauskas, Sebastián; Quilodrán, Julio; Valenzuela, Jorge; Martínez, Javier; Rivero, Natalia; Arias, Pablo; Díaz, Franco

    2017-10-06

    Analysis of respiratory mechanics during mechanical ventilation (MV) is able to estimate resistive, elastic and inertial components of the working pressure of the respiratory system. Our aim was to discriminate the components of the working pressure of the respiratory system in infants on MV with severe bronchiolitis admitted to two PICU's. Infants younger than 1 year old with acute respiratory failure caused by severe bronchiolitis underwent neuromuscular blockade, tracheal intubation and volume controlled MV. Shortly after intubation studies of pulmonary mechanics were performed using inspiratory and expiratory breath hold. The maximum inspiratory and expiratory flow (QI and QE) as well as peak inspiratory (PIP), plateau (PPL) and total expiratory pressures (tPEEP) were measured. Inspiratory and expiratory resistances (RawI and RawE) and Time Constants (K TI and K TE ) were calculated. We included 16 patients, of median age 2.5 (1-5.8) months. Bronchiolitis due to respiratory syncytial virus was the main etiology (93.8%) and 31.3% had comorbidities. Measured respiratory pressures were PIP 29 (26-31), PPL 24 (20-26), tPEEP 9 [8-11] cmH2O. Elastic component of the working pressure was significantly higher than resistive and both higher than threshold (tPEEP - PEEP) (P mechanics of infants with severe bronchiolitis receiving MV shows that the elastic component of the working pressure of the respiratory system is the most important. The elastic and resistive components in conjunction with flow profile are characteristic of restrictive diseases. A better understanding of lung mechanics in this group of patients may lead to change the traditional ventilatory approach to severe bronchiolitis.

  1. Lugejate valik : Peep Vain on parim / Marko Liibak

    Index Scriptorium Estoniae

    Liibak, Marko

    2007-01-01

    Aripaev.ee ja ajaleht Äripäev korraldasid lugejate seas küsitluse, mille käigus valiti Eesti parimaks koolitajaks Vain & Partnerite omanik ning koolituskonsultant Peep Vain. Teisele kohale tuli koolitaja, juhtimiskonsultant ja nõustaja ning Tallinn Ülikooli kliinilise psühholoogia professor Mare Pork. Järgnesid Ülo Vihma, Indrek Saul, Tiit Valm, Mihkel Pärjamäe ning Alexander Kotchubei

  2. Evaluation of lung recruitment maneuvers in acute respiratory distress syndrome using computer simulation.

    Science.gov (United States)

    Das, Anup; Cole, Oana; Chikhani, Marc; Wang, Wenfei; Ali, Tayyba; Haque, Mainul; Bates, Declan G; Hardman, Jonathan G

    2015-01-12

    Direct comparison of the relative efficacy of different recruitment maneuvers (RMs) for patients with acute respiratory distress syndrome (ARDS) via clinical trials is difficult, due to the heterogeneity of patient populations and disease states, as well as a variety of practical issues. There is also significant uncertainty regarding the minimum values of positive end-expiratory pressure (PEEP) required to ensure maintenance of effective lung recruitment using RMs. We used patient-specific computational simulation to analyze how three different RMs act to improve physiological responses, and investigate how different levels of PEEP contribute to maintaining effective lung recruitment. We conducted experiments on five 'virtual' ARDS patients using a computational simulator that reproduces static and dynamic features of a multivariable clinical dataset on the responses of individual ARDS patients to a range of ventilator inputs. Three recruitment maneuvers (sustained inflation (SI), maximal recruitment strategy (MRS) followed by a titrated PEEP, and prolonged recruitment maneuver (PRM)) were implemented and evaluated for a range of different pressure settings. All maneuvers demonstrated improvements in gas exchange, but the extent and duration of improvement varied significantly, as did the observed mechanism of operation. Maintaining adequate post-RM levels of PEEP was seen to be crucial in avoiding cliff-edge type re-collapse of alveolar units for all maneuvers. For all five patients, the MRS exhibited the most prolonged improvement in oxygenation, and we found that a PEEP setting of 35 cm H2O with a fixed driving pressure of 15 cm H2O (above PEEP) was sufficient to achieve 95% recruitment. Subsequently, we found that PEEP titrated to a value of 16 cm H2O was able to maintain 95% recruitment in all five patients. There appears to be significant scope for reducing the peak levels of PEEP originally specified in the MRS and hence to avoid exposing the lung to

  3. Voyeuristi alla finestra: Peeping Tom, dalla leggenda al cinema

    Directory of Open Access Journals (Sweden)

    Laura Staiano

    2015-01-01

    Full Text Available This essay deals with voyeuristic attitudes and ʹscopic powerʹ, i.e. the power to gaze at forbidden things and people without being seen. Indeed, its object par excellence coincides with female nakedness, while its subject is an invisible masculinity, which takes delight in looking. The paper is based on a study of the Anglo-Saxon legend of Lady Godiva and it is strictly connected with the subject of my dissertation in progress – metaphorical and physical blindness in 18th century French literature (since several voyeurs got blind because of their instincts and desires. Lady Godiva’s voyeur, called Peeping Tom, is struck blind for having looked out of his window and seen the noblewoman riding naked. This legend has inspired many artists in different fields, and nowadays its heroine is very famous and venerated. In particular, this essay focuses on the relation between this legend and compulsive looking (or scopophilia in two renowned films, Rear Window by Alfred Hitchcock, and Peeping Tom by Michael Powell.

  4. Impact of Different Ventilation Strategies on Driving Pressure, Mechanical Power, and Biological Markers During Open Abdominal Surgery in Rats.

    Science.gov (United States)

    Maia, Lígia de A; Samary, Cynthia S; Oliveira, Milena V; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Morales, Marcelo M; Schultz, Marcus J; Abreu, Marcelo G; Pelosi, Paolo; Silva, Pedro L; Rocco, Patricia Rieken Macedo

    2017-10-01

    Intraoperative mechanical ventilation may yield lung injury. To date, there is no consensus regarding the best ventilator strategy for abdominal surgery. We aimed to investigate the impact of the mechanical ventilation strategies used in 2 recent trials (Intraoperative Protective Ventilation [IMPROVE] trial and Protective Ventilation using High versus Low PEEP [PROVHILO] trial) on driving pressure (ΔPRS), mechanical power, and lung damage in a model of open abdominal surgery. Thirty-five Wistar rats were used, of which 28 were anesthetized, and a laparotomy was performed with standardized bowel manipulation. Postoperatively, animals (n = 7/group) were randomly assigned to 4 hours of ventilation with: (1) tidal volume (VT) = 7 mL/kg and positive end-expiratory pressure (PEEP) = 1 cm H2O without recruitment maneuvers (RMs) (low VT/low PEEP/RM-), mimicking the low-VT/low-PEEP strategy of PROVHILO; (2) VT = 7 mL/kg and PEEP = 3 cm H2O with RMs before laparotomy and hourly thereafter (low VT/moderate PEEP/4 RM+), mimicking the protective ventilation strategy of IMPROVE; (3) VT = 7 mL/kg and PEEP = 6 cm H2O with RMs only before laparotomy (low VT/high PEEP/1 RM+), mimicking the strategy used after intubation and before extubation in PROVHILO; or (4) VT = 14 mL/kg and PEEP = 1 cm H2O without RMs (high VT/low PEEP/RM-), mimicking conventional ventilation used in IMPROVE. Seven rats were not tracheotomized, operated, or mechanically ventilated, and constituted the healthy nonoperated and nonventilated controls. Low VT/moderate PEEP/4 RM+ and low VT/high PEEP/1 RM+, compared to low VT/low PEEP/RM- and high VT/low PEEP/RM-, resulted in lower ΔPRS (7.1 ± 0.8 and 10.2 ± 2.1 cm H2O vs 13.9 ± 0.9 and 16.9 ± 0.8 cm H2O, respectively; Pmechanical power (63 ± 7 and 79 ± 20 J/min vs 110 ± 10 and 120 ± 20 J/min, respectively; P = .007). Low VT/high PEEP/1 RM+ was associated with less alveolar collapse than low VT/low PEEP/RM- (P = .03). E-cadherin expression was higher in

  5. Parameters affecting the tidal volume during expiratory abdominal compression in patients with prolonged tracheostomy mechanical ventilation.

    Science.gov (United States)

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-07-01

    [Purpose] The aim of this study was to clarify physical parameters affecting the tidal volume during expiratory abdominal compression in patients with prolonged tracheostomy mechanical ventilation. [Methods] Eighteen patients with prolonged mechanical ventilation were included in this study. Expiratory abdominal compression was performed on patients lying in a supine position. The abdomen above the navel was vertically compressed in synchronization with expiration and released with inspiration. We measured the tidal volume during expiratory abdominal compression. [Results] The mean tidal volume during expiratory abdominal compression was higher than that at rest (430.6 ± 127.1 mL vs. 344.0 ± 94.3 mL). The tidal volume during expiratory abdominal compression was correlated with weight, days of ventilator support, dynamic compliance and abdominal expansion. Stepwise multiple regression analysis revealed that weight (β = 0.499), dynamic compliance (β = 0.387), and abdominal expansion (β = 0.365) were factors contributing to the tidal volume during expiratory abdominal compression. [Conclusion] Expiratory abdominal compression increased the tidal volume in patients with prolonged tracheostomy mechanical ventilation. The tidal volume during expiratory abdominal compression was influenced by each of the pulmonary conditions and the physical characteristics.

  6. Investigation of continuous effect modifiers in a meta-analysis on higher versus lower PEEP in patients requiring mechanical ventilation--protocol of the ICEM study.

    Science.gov (United States)

    Kasenda, Benjamin; Sauerbrei, Willi; Royston, Patrick; Briel, Matthias

    2014-05-20

    Categorizing an inherently continuous predictor in prognostic analyses raises several critical methodological issues: dependence of the statistical significance on the number and position of the chosen cut-point(s), loss of statistical power, and faulty interpretation of the results if a non-linear association is incorrectly assumed to be linear. This also applies to a therapeutic context where investigators of randomized clinical trials (RCTs) are interested in interactions between treatment assignment and one or more continuous predictors. Our goal is to apply the multivariable fractional polynomial interaction (MFPI) approach to investigate interactions between continuous patient baseline variables and the allocated treatment in an individual patient data meta-analysis of three RCTs (N = 2,299) from the intensive care field. For each study, MFPI will provide a continuous treatment effect function. Functions from each of the three studies will be averaged by a novel meta-analysis approach for functions. We will plot treatment effect functions separately for each study and also the averaged function. The averaged function with a related confidence interval will provide a suitable basis to assess whether a continuous patient characteristic modifies the treatment comparison and may be relevant for clinical decision-making. The compared interventions will be a higher or lower positive end-expiratory pressure (PEEP) ventilation strategy in patients requiring mechanical ventilation. The continuous baseline variables body mass index, PaO2/FiO2, respiratory compliance, and oxygenation index will be the investigated potential effect modifiers. Clinical outcomes for this analysis will be in-hospital mortality, time to death, time to unassisted breathing, and pneumothorax. This project will be the first meta-analysis to combine continuous treatment effect functions derived by the MFPI procedure separately in each of several RCTs. Such an approach requires individual

  7. Use of positive pressure in preoperative and intraoperative of bariatric surgery and its effect on the time of extubation

    Directory of Open Access Journals (Sweden)

    Letícia Baltieri

    2015-04-01

    Full Text Available BACKGROUND AND OBJECTIVE: To investigate the influence of intraoperative and preoperative positive pressure in the time of extubation in patients undergoing bariatric surgery. METHOD: Randomized clinical trial, in which 40 individuals with a body mass index between 40 and 55 kg/m2, age between 25 and 55 years, nonsmokers, underwent bariatric surgery type Roux-en-Y gastric bypass by laparotomy and with normal preoperative pulmonary function were randomized into the following groups: G-pre (n = 10: individuals who received treatment with noninvasive positive pressure before surgery for 1 h; G-intra (n = 10: individuals who received positive end-expiratory pressure of 10 cm H2O throughout the surgical procedure; and G-control (n = 20: not received any preoperative or intraoperative intervention. Following were recorded: time between induction of anesthesia and extubation, between the end of anesthesia and extubation, duration of mechanical ventilation, and time between extubation and discharge from the post-anesthetic recovery. RESULTS: There was no statistical difference between groups. However, when applied to the Cohen coefficient, the use of positive end-expiratory pressure of 10 cm H2O during surgery showed a large effect on the time between the end of anesthesia and extubation. About this same time, the treatment performed preoperatively showed moderate effect. CONCLUSION: The use of positive end-expiratory pressure of 10 cm H2O in the intraoperative and positive pressure preoperatively, influenced the time of extubation of patients undergoing bariatric surgery.

  8. Lung-protective ventilation in abdominal surgery.

    Science.gov (United States)

    Futier, Emmanuel; Jaber, Samir

    2014-08-01

    To provide the most recent and relevant clinical evidence regarding the use of prophylactic lung-protective mechanical ventilation in abdominal surgery. Evidence is accumulating, suggesting an association between intraoperative mechanical ventilation strategy and postoperative pulmonary complications in patients undergoing abdominal surgery. Nonprotective ventilator settings, especially high tidal volume (>10-12 ml/kg), very low level of positive end-expiratory pressure (PEEP, ventilator-associated lung injury in patients with healthy lungs. Stimulated by the previous findings in patients with acute respiratory distress syndrome, the use of lower tidal volume ventilation is becoming increasingly more common in the operating room. However, lowering tidal volume, though important, is only part of the overall multifaceted approach of lung-protective mechanical ventilation. Recent data provide compelling evidence that prophylactic lung-protective mechanical ventilation using lower tidal volume (6-8 ml/kg of predicted body weight), moderate PEEP (6-8 cm H2O), and recruitment maneuvers is associated with improved functional or physiological and clinical postoperative outcome in patients undergoing abdominal surgery. The use of prophylactic lung-protective ventilation can help in improving the postoperative outcome.

  9. Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study.

    Science.gov (United States)

    Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2014-01-01

    Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.

  10. Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study* **

    Science.gov (United States)

    Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2014-01-01

    Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. PMID:25029653

  11. Comparison of changes in tidal volume associated with expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation

    OpenAIRE

    Morino, Akira; Shida, Masahiro; Tanaka, Masashi; Sato, Kimihiro; Seko, Toshiaki; Ito, Shunsuke; Ogawa, Shunichi; Takahashi, Naoaki

    2015-01-01

    [Purpose] This study was designed to compare and clarify the relationship between expiratory rib cage compression and expiratory abdominal compression in patients on prolonged mechanical ventilation, with a focus on tidal volume. [Subjects and Methods] The subjects were 18 patients on prolonged mechanical ventilation, who had undergone tracheostomy. Each patient received expiratory rib cage compression and expiratory abdominal compression; the order of implementation was randomized. Subjects ...

  12. [Alveolar ventilation and recruitment under lung protective ventilation].

    Science.gov (United States)

    Putensen, Christian; Muders, Thomas; Kreyer, Stefan; Wrigge, Hermann

    2008-11-01

    Goal of mechanical ventilation is to improve gas exchange and reduce work of breathing without contributing to further lung injury. Besides providing adequate EELV and thereby arterial oxygenation PEEP in addition to a reduction in tidal volume is required to prevent cyclic alveolar collapse and tidal recruitment and hence protective mechanical ventilation. Currently, there is no consensus if and if yes at which price alveolar recruitment with high airway pressures should be intended ("open up the lung"), or if it is more important to reduce the mechanical stress and strain to the lungs as much as possible ("keep the lung closed"). Potential of alveolar recruitment differs from patient to patient but also between lung regions. Potential for recruitment depends probably more on regional lung mechanics - especially on lung elastance - than on the underlying disease. Based on available data neither high PEEP nor other methods used for alveolar recruitment could demonstrate a survival benefit in patients with ARDS. These results may support an individualized titration of PEEP or other manoeuvres used for recruitment taking into consideration the regional effects. Bedside imaging techniques allowing titration of PEEP or other manoeuvres to prevent end-expiratory alveolar collapse (tidal recruitment) and inspiratory overinflation may be a promising development.

  13. Predicting the lung compliance of mechanically ventilated patients via statistical modeling

    International Nuclear Information System (INIS)

    Ganzert, Steven; Kramer, Stefan; Guttmann, Josef

    2012-01-01

    To avoid ventilator associated lung injury (VALI) during mechanical ventilation, the ventilator is adjusted with reference to the volume distensibility or ‘compliance’ of the lung. For lung-protective ventilation, the lung should be inflated at its maximum compliance, i.e. when during inspiration a maximal intrapulmonary volume change is achieved by a minimal change of pressure. To accomplish this, one of the main parameters is the adjusted positive end-expiratory pressure (PEEP). As changing the ventilator settings usually produces an effect on patient's lung mechanics with a considerable time delay, the prediction of the compliance change associated with a planned change of PEEP could assist the physician at the bedside. This study introduces a machine learning approach to predict the nonlinear lung compliance for the individual patient by Gaussian processes, a probabilistic modeling technique. Experiments are based on time series data obtained from patients suffering from acute respiratory distress syndrome (ARDS). With a high hit ratio of up to 93%, the learned models could predict whether an increase/decrease of PEEP would lead to an increase/decrease of the compliance. However, the prediction of the complete pressure–volume relation for an individual patient has to be improved. We conclude that the approach is well suitable for the given problem domain but that an individualized feature selection should be applied for a precise prediction of individual pressure–volume curves. (paper)

  14. Acute Respiratory Distress Syndrome (ARDS After Nitric Acid Inhalation

    Directory of Open Access Journals (Sweden)

    Gülay Kır

    2014-12-01

    Full Text Available Lung injury resulting from inhalation of chemical products continues to be associated with high morbidity and mortality. Concentrated nitric acids are also extremely corrosive fuming chemical liquids. Fumes of nitric acid (HNO3 and various oxides of nitrogen such as nitric oxide (NO and nitrogen dioxide (NO2 may cause fatal illnesses such as severe pulmonary edema and acute respiratory distress syndrome (ARDS when inhaled. Intensive respiratory management including mechanical ventilation with positive end expiratory pressure (PEEP, inverse ratio ventilation, replacement of surfactant and extracorporeal membrane oxygenation (ECMO, steroids and n-acetylcysteine (NAC may improve survival. In this case report we present the diagnosis and successful treatment of a 57 years old male patient who developed ARDS following pulmonary edema due to nitric acid fumes inhalation.

  15. MANAGEMENT OF A PATIENT WITH ARDS: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Preethi Thomas

    2014-12-01

    Full Text Available Acute Respiratory Distress Syndrome (ARDS is a permeability pulmonary edema characterized by increased permeability of pulmonary capillary endothelial cells and alveolar epithelial cells, leading to hypoxemia that is refractory to usual oxygen therapy. ARDS is characterized by a brief precipitating event followed by rapidly developing dyspnea. These patients have markedly impaired respiratory system compliance and reduced lung volume. The hypoxemia is refractory to low fraction of oxygen concentration and low positive end expiratory pressure (PEEP. The mortality of ARDS is around 35-40%. Current therapy of ARDS resolves around treatment of underlying cause, lung protective ventilatory strategy and appropriate fluid management. We present a case of ARDS managed in our ICU along with a detailed discussion about the pathophysiology and treatment modalities for the management of a patient with ARDS.

  16. A new design for high stability pressure-controlled ventilation for small animal lung imaging

    International Nuclear Information System (INIS)

    Kitchen, M J; Habib, A; Lewis, R A; Fouras, A; Dubsky, S; Wallace, M J; Hooper, S B

    2010-01-01

    We have developed a custom-designed ventilator to deliver a stable pressure to the lungs of small animals for use in imaging experiments. Our ventilator was designed with independent pressure vessels to separately control the Peak Inspiratory Pressure (PIP) and Positive End Expiratory Pressure (PEEP) to minimise pressure fluctuations during the ventilation process. The ventilator was computer controlled through a LabVIEW interface, enabling experimental manipulations to be performed remotely whilst simultaneously imaging the lungs in situ. Mechanical ventilation was successfully performed on newborn rabbit pups to assess the most effective ventilation strategies for aerating the lungs at birth. Highly stable pressures enabled reliable respiratory gated acquisition of projection radiographs and a stable prolonged (15 minute) breath-hold for high-resolution computed tomography of deceased rabbit pups at different lung volumes.

  17. Expiratory muscle control during vomiting - Role of brain stem expiratory neurons

    Science.gov (United States)

    Miller, A. D.; Tan, L. K.

    1987-01-01

    The neural mechanisms controlling the muscles involved during vomiting were examined using decerebrated cats. In one experiment, the activity of the ventral respiratory group (VRG) expiratory (E) neurons was recorded during induced 'fictive vomiting' (i.e., a series of bursts of coactivation of abdominal and phrenic nerves that would be expected to produce expulsion in unparalyzed animals) and vomiting. In a second, abdominal muscle electromyographic and nerve activity were compared before and after sectioning the axons of descending VRG E neurons as they cross the midline between C1 and the obex (the procedure that is known to abolish expiratory modulation of internal intercostal muscle activity). The results of the study indicate that the abdominal muscles are controlled differently during respiration and vomiting.

  18. Effect of different seated positions on lung volume and oxygenation in acute respiratory distress syndrome.

    Science.gov (United States)

    Dellamonica, J; Lerolle, N; Sargentini, C; Hubert, S; Beduneau, G; Di Marco, F; Mercat, A; Diehl, J L; Richard, J C M; Bernardin, G; Brochard, L

    2013-06-01

    Lung volume available for ventilation is markedly decreased during acute respiratory distress syndrome. Body positioning may contribute to increase lung volume and partial verticalization is simple to perform. This study evaluated whether verticalization had parallel effects on oxygenation and end expiratory lung volume (EELV). Prospective multicenter study in 40 mechanically ventilated patients with ALI/ARDS in five university hospital MICUs. We evaluated four 45-min successive trunk position epochs (supine slightly elevated at 15°; semi recumbent with trunk elevated at 45°; seated with trunk elevated at 60° and legs down at 45°; back to supine). Arterial blood gases, EELV measured using the nitrogen washin/washout, and static compliance were measured. Responders were defined by a PaO₂/FiO₂ increase >20 % between supine and seated position. Results are median [25th-75th percentiles]. With median PEEP = 10 cmH₂O, verticalization increased lung volume but only responders (13 patients, 32 %) had a significant increase in EELV/PBW (predicted body weight) compared to baseline. This increase persisted at least partially when patients were positioned back to supine. Responders had a lower EELV/PBW supine [14 mL/kg (13-15) vs. 18 mL/kg (15-27) (p = 0.005)] and a lower compliance [30 mL/cmH₂O (22-38) vs. 42 (30-46) (p = 0.01)] than non-responders. Strain decreased with verticalization for responders. EELV/PBW increase and PaO₂/FiO₂ increase were not correlated. Verticalization is easily achieved and improves oxygenation in approximately 32 % of the patients together with an increase in EELV. Nonetheless, effect of verticalization on EELV/PBW is not predictable by PaO₂/FiO₂ increase, its monitoring may be helpful for strain optimization.

  19. Effect of nasal continuous and biphasic positive airway pressure on lung volume in preterm infants

    NARCIS (Netherlands)

    Miedema, Martijn; van der Burg, Pauline S.; Beuger, Sabine; de Jongh, Frans H.; Frerichs, Inez; van Kaam, Anton H.

    2013-01-01

    To monitor regional changes in end-expiratory lung volume (EELV), tidal volumes, and their ventilation distribution during different levels of nasal continuous positive airway pressure (nCPAP) and nasal biphasic positive airway pressure (BiPAP) in stable preterm infants. By using electrical

  20. Human or monitor feedback to improve mask ventilation during simulated neonatal cardiopulmonary resuscitation.

    Science.gov (United States)

    Binder, Corinna; Schmölzer, Georg M; O'Reilly, Megan; Schwaberger, Bernhard; Urlesberger, Berndt; Pichler, Gerhard

    2014-03-01

    To investigate if external chest compressions (ECC) increase mask leak, and if human or technical feedback improves mask ventilation during simulated neonatal cardiopulmonary resuscitation (CPR). In this observational study, 32 participants delivered positive pressure ventilation (PPV) to a modified, leak-free manikin via facemask. Mask leak, tidal volume (VT), positive end expiratory pressure (PEEP) and respiratory rate (RR) were measured with a respiratory function monitor (RFM). Participants had to perform four studies. In the first study, participants performed PPV alone as baseline. Thereafter, three studies were performed in random order. In the PPV+ECC+manometer group, participants had to observe the manometer while the RFM was covered; in the PPV+ECC+RFM group, the RFM was used while the manometer was covered; and in the PPV+ECC+verbal feedback group, the RFM and manometer were covered while a team leader viewed the RFM and provided verbal feedback to the participants. Median (IQR) mask leak of all studies was 15% (5-47%). Comparing the studies, PPV+ECC+RFM and PPV+ECC+verbal feedback had significantly less mask leak than PPV+ECC+manometer. Mean (SD) VT of all studies was 9.5±3.5 mL. Comparing all studies, PPV+ECC+RFM had a significantly higher VT than PPV and PPV+ECC+manometer. As well, PPV+ECC+verbal feedback had a significantly higher VT than PPV. PEEP and RR were within our target, mean (SD) PEEP was 6±2 cmH2O and RR was 36±13/min. During simulated neonatal CPR, ECCs did not influence mask leak, and a RFM and verbal feedback were helpful methods to reduce mask leak and increase VT significantly.

  1. Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

    Science.gov (United States)

    Wall, M A; Olson, D; Bonn, B A; Creelman, T; Buist, A S

    1982-02-01

    Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

  2. Chest physiotherapy with positive expiratory pressure breathing after abdominal and thoracic surgery: a systematic review.

    Science.gov (United States)

    Orman, J; Westerdahl, E

    2010-03-01

    A variety of chest physiotherapy techniques are used following abdominal and thoracic surgery to prevent or reduce post-operative complications. Breathing techniques with a positive expiratory pressure (PEP) are used to increase airway pressure and improve pulmonary function. No systematic review of the effects of PEP in surgery patients has been performed previously. The purpose of this systematic review was to determine the effect of PEP breathing after an open upper abdominal or thoracic surgery. A literature search of randomised-controlled trials (RCT) was performed in five databases. The trials included were systematically reviewed by two independent observers and critically assessed for methodological quality. We selected six RCT evaluating the PEP technique performed with a mechanical device in spontaneously breathing adult patients after abdominal or thoracic surgery via thoracotomy. The methodological quality score varied between 4 and 6 on the Physiotherapy Evidence Database score. The studies were published between 1979 and 1993. Only one of the included trials showed any positive effects of PEP compared to other breathing techniques. Today, there is scarce scientific evidence that PEP treatment is better than other physiotherapy breathing techniques in patients undergoing abdominal or thoracic surgery. There is a lack of studies investigating the effect of PEP over placebo or no physiotherapy treatment.

  3. Data-driven classification of ventilated lung tissues using electrical impedance tomography

    International Nuclear Information System (INIS)

    Gómez-Laberge, Camille; Hogan, Matthew J; Elke, Gunnar; Weiler, Norbert; Frerichs, Inéz; Adler, Andy

    2011-01-01

    Current methods for identifying ventilated lung regions utilizing electrical impedance tomography images rely on dividing the image into arbitrary regions of interest (ROI), manually delineating ROI, or forming ROI with pixels whose signal properties surpass an arbitrary threshold. In this paper, we propose a novel application of a data-driven classification method to identify ventilated lung ROI based on forming k clusters from pixels with correlated signals. A standard first-order model for lung mechanics is then applied to determine which ROI correspond to ventilated lung tissue. We applied the method in an experimental study of 16 mechanically ventilated swine in the supine position, which underwent changes in positive end-expiratory pressure (PEEP) and fraction of inspired oxygen (F I O 2 ). In each stage of the experimental protocol, the method performed best with k = 4 and consistently identified 3 lung tissue ROI and 1 boundary tissue ROI in 15 of the 16 subjects. When testing for changes from baseline in lung position, tidal volume, and respiratory system compliance, we found that PEEP displaced the ventilated lung region dorsally by 2 cm, decreased tidal volume by 1.3%, and increased the respiratory system compliance time constant by 0.3 s. F I O 2 decreased tidal volume by 0.7%. All effects were tested at p < 0.05 with n = 16. These findings suggest that the proposed ROI detection method is robust and sensitive to ventilation dynamics in the experimental setting

  4. Volumetric expiratory high-resolution CT of the lung

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Hatabu, Hiroto

    2004-01-01

    We developed a volumetric expiratory high-resolution CT (HRCT) protocol that provides combined inspiratory and expiratory volumetric imaging of the lung without increasing radiation exposure, and conducted a preliminary feasibility assessment of this protocol to evaluate diffuse lung disease with small airway abnormalities. The volumetric expiratory high-resolution CT increased the detectability of the conducting airway to the areas of air trapping (P<0.0001), and added significant information about extent and distribution of air trapping (P<0.0001)

  5. Right ventricular function during one-lung ventilation: effects of pressure-controlled and volume-controlled ventilation.

    Science.gov (United States)

    Al Shehri, Abdullah M; El-Tahan, Mohamed R; Al Metwally, Roshdi; Qutub, Hatem; El Ghoneimy, Yasser F; Regal, Mohamed A; Zien, Haytham

    2014-08-01

    To test the effects of pressure-controlled (PCV) and volume-controlled (VCV) ventilation during one-lung ventilation (OLV) for thoracic surgery on right ventricular (RV) function. A prospective, randomized, double-blind, controlled, crossover study. A single university hospital. Fourteen pairs of consecutive patients scheduled for elective thoracotomy. Patients were assigned randomly to ventilate the dependent lung with PCV or VCV mode, each in a randomized crossover order using tidal volume of 6 mL/kg, I: E ratio 1: 2.5, positive end-expiratory pressure (PEEP) of 5 cm H2O and respiratory rate adjusted to maintain normocapnia. Intraoperative changes in RV function (systolic and early diastolic tricuspid annular velocity (TAV), end-systolic volume (ESV), end-diastolic volume (EDV) and fractional area changes (FAC)), airway pressures, compliance and oxygenation index were recorded. The use of PCV during OLV resulted in faster systolic (10.1±2.39 vs. 5.8±1.67 cm/s, respectively), diastolic TAV (9.2±1.99 vs. 4.6±1.42 cm/s, respectively) (prights reserved.

  6. Glutamine Attenuates Acute Lung Injury Caused by Acid Aspiration

    Directory of Open Access Journals (Sweden)

    Chih-Cheng Lai

    2014-08-01

    Full Text Available Inadequate ventilator settings may cause overwhelming inflammatory responses associated with ventilator-induced lung injury (VILI in patients with acute respiratory distress syndrome (ARDS. Here, we examined potential benefits of glutamine (GLN on a two-hit model for VILI after acid aspiration-induced lung injury in rats. Rats were intratracheally challenged with hydrochloric acid as a first hit to induce lung inflammation, then randomly received intravenous GLN or lactated Ringer’s solution (vehicle control thirty min before different ventilator strategies. Rats were then randomized to receive mechanical ventilation as a second hit with a high tidal volume (TV of 15 mL/kg and zero positive end-expiratory pressure (PEEP or a low TV of 6 mL/kg with PEEP of 5 cm H2O. We evaluated lung oxygenation, inflammation, mechanics, and histology. After ventilator use for 4 h, high TV resulted in greater lung injury physiologic and biologic indices. Compared with vehicle treated rats, GLN administration attenuated lung injury, with improved oxygenation and static compliance, and decreased respiratory elastance, lung edema, extended lung destruction (lung injury scores and lung histology, neutrophil recruitment in the lung, and cytokine production. Thus, GLN administration improved the physiologic and biologic profiles of this experimental model of VILI based on the two-hit theory.

  7. Bussijuhtide kindrali rasked päevad / Peep Peterson ; interv. Tanel Raig

    Index Scriptorium Estoniae

    Peterson, Peep, 1975-

    2007-01-01

    Eesti Transpordi- ja Teetöötajate Ametiühingu esimees Peep Peterson vastab bussijuhtide ja tööandjate vahelisi lahkhelisid, ametiühinguliikumist ning kokkuleppe sõlmimist puudutavatele küsimustele. Kommenteerivad: Villem Tori. Streikija iseloomuga raske vastane; Henn Pärn. Peterson saavutas maksimumide maksimumi; Harri Taliga. Ametiühingu liidritel erinevad arusaamad. Lisa: Fakte eluloost

  8. Intratidal Overdistention and Derecruitment in the Injured Lung: A Simulation Study.

    Science.gov (United States)

    Amini, Reza; Herrmann, Jacob; Kaczka, David W

    2017-03-01

    Ventilated patients with the acute respiratory distress syndrome (ARDS) are predisposed to cyclic parenchymal overdistention and derecruitment, which may worsen existing injury. We hypothesized that intratidal variations in global mechanics, as assessed at the airway opening, would reflect such distributed processes. We developed a computational lung model for determining local instantaneous pressure distributions and mechanical impedances continuously during a breath. Based on these distributions and previous literature, we simulated the within-breath variability of airway segment dimensions, parenchymal viscoelasticity, and acinar recruitment in an injured canine lung for tidal volumes( V T ) of 10, 15, and 20 mL·kg -1 and positive end-expiratory pressures (PEEP) of 5, 10, and 15 cm H 2 O. Acini were allowed to transition between recruited and derecruited states when exposed to stochastically determined critical opening and closing pressures, respectively. For conditions of low V T and low PEEP, we observed small intratidal variations in global resistance and elastance, with a small number of cyclically recruited acini. However, with higher V T and PEEP, larger variations in resistance and elastance were observed, and the majority of acini remained open throughout the breath. Changes in intratidal resistance, elastance, and impedance followed well-defined parabolic trajectories with tracheal pressure, achieving minima near 12 to 16 cm H 2 O. Intratidal variations in lung mechanics may allow for optimization of ventilator settings in patients with ARDS, by balancing lung recruitment against parenchymal overdistention. Titration of airway pressures based on variations in intratidal mechanics may mitigate processes associated with injurious ventilation.

  9. Comparison of lung protective ventilation strategies in a rabbit model of acute lung injury.

    Science.gov (United States)

    Rotta, A T; Gunnarsson, B; Fuhrman, B P; Hernan, L J; Steinhorn, D M

    2001-11-01

    To determine the impact of different protective and nonprotective mechanical ventilation strategies on the degree of pulmonary inflammation, oxidative damage, and hemodynamic stability in a saline lavage model of acute lung injury. A prospective, randomized, controlled, in vivo animal laboratory study. Animal research facility of a health sciences university. Forty-six New Zealand White rabbits. Mature rabbits were instrumented with a tracheostomy and vascular catheters. Lavage-injured rabbits were randomized to receive conventional ventilation with either a) low peak end-expiratory pressure (PEEP; tidal volume of 10 mL/kg, PEEP of 2 cm H2O); b) high PEEP (tidal volume of 10 mL/kg, PEEP of 10 cm H2O); c) low tidal volume with PEEP above Pflex (open lung strategy, tidal volume of 6 mL/kg, PEEP set 2 cm H2O > Pflex); or d) high-frequency oscillatory ventilation. Animals were ventilated for 4 hrs. Lung lavage fluid and tissue samples were obtained immediately after animals were killed. Lung lavage fluid was assayed for measurements of total protein, elastase activity, tumor necrosis factor-alpha, and malondialdehyde. Lung tissue homogenates were assayed for measurements of myeloperoxidase activity and malondialdehyde. The need for inotropic support was recorded. Animals that received a lung protective strategy (open lung or high-frequency oscillatory ventilation) exhibited more favorable oxygenation and lung mechanics compared with the low PEEP and high PEEP groups. Animals ventilated by a lung protective strategy also showed attenuation of inflammation (reduced tracheal fluid protein, tracheal fluid elastase, tracheal fluid tumor necrosis factor-alpha, and pulmonary leukostasis). Animals treated with high-frequency oscillatory ventilation had attenuated oxidative injury to the lung and greater hemodynamic stability compared with the other experimental groups. Both lung protective strategies were associated with improved oxygenation, attenuated inflammation, and

  10. Effects of nasal positive expiratory pressure on dynamic hyperinflation and 6-minute walk test in patients with COPD.

    Science.gov (United States)

    Wibmer, Thomas; Rüdiger, Stefan; Heitner, Claudia; Kropf-Sanchen, Cornelia; Blanta, Ioanna; Stoiber, Kathrin M; Rottbauer, Wolfgang; Schumann, Christian

    2014-05-01

    Dynamic hyperinflation is an important target in the treatment of COPD. There is increasing evidence that positive expiratory pressure (PEP) could reduce dynamic hyperinflation during exercise. PEP application through a nasal mask and a flow resistance device might have the potential to be used during daily physical activities as an auxiliary strategy of ventilatory assistance. The aim of this study was to determine the effects of nasal PEP on lung volumes during physical exercise in patients with COPD. Twenty subjects (mean ± SD age 69.4 ± 6.4 years) with stable mild-to-severe COPD were randomized to undergo physical exercise with nasal PEP breathing, followed by physical exercise with habitual breathing, or vice versa. Physical exercise was induced by a standard 6-min walk test (6 MWT) protocol. PEP was applied by means of a silicone nasal mask loaded with a fixed-orifice flow resistor. Body plethysmography was performed immediately pre-exercise and post-exercise. Differences in mean pre- to post-exercise changes in total lung capacity (-0.63 ± 0.80 L, P = .002), functional residual capacity (-0.48 ± 0.86 L, P = .021), residual volume (-0.56 ± 0.75 L, P = .004), S(pO2) (-1.7 ± 3.4%, P = .041), and 6 MWT distance (-30.8 ± 30.0 m, P = .001) were statistically significant between the experimental and the control interventions. The use of flow-dependent expiratory pressure, applied with a nasal mask and a PEP device, might promote significant reduction of dynamic hyperinflation during walking exercise. Further studies are warranted addressing improvements in endurance performance under regular application of nasal PEP during physical activities.

  11. Raudna põhikooli spordihoone Heimtalis = Raudna School Sports Facility in Heimtali / Peep Jänes

    Index Scriptorium Estoniae

    Jänes, Peep, 1936-

    2009-01-01

    2008. a. valminud spordihoonest, mille autor on Peep Jänes, projekteerija GS-Dis, sisekujundajad Signe ja Gildardas Stokas. Spordihoone rajati 1860. a. ehitatud mõisa ringtalli välismüüri sisealale ja restaureeriti ajalooline ringmüür

  12. Relationship between pre-extubation positive endexpiratory pressure and oxygenation after coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Reijane Oliveira Lima

    2015-08-01

    Full Text Available Abstract Introduction After removal of endotracheal tube and artificial ventilation, ventilatory support should be continued, offering oxygen supply to ensure an arterial oxygen saturation close to physiological. Objective: The aim of this study was to investigate the effects of positive-end expiratory pressure before extubation on the oxygenation indices of patients undergoing coronary artery bypass grafting. Methods: A randomized clinical trial with seventy-eight patients undergoing coronary artery bypass grafting divided into three groups and ventilated with different positive-end expiratory pressure levels prior to extubation: Group A, 5 cmH2O (n=32; Group B, 8 cmH2O (n=26; and Group C, 10 cmH2O (n=20. Oxygenation index data were obtained from arterial blood gas samples collected at 1, 3, and 6 h after extubation. Patients with chronic pulmonary disease and those who underwent off-pump, emergency, or combined surgeries were excluded. For statistical analysis, we used Shapiro-Wilk, G, Kruskal-Wallis, and analysis of variance tests and set the level of significance at P<0.05. Results Groups were homogenous with regard to demographic, clinical, and surgical variables. There were no statistically significant differences between groups in the first 6 h after extubation with regard to oxygenation indices and oxygen therapy utilization. Conclusion: In this sample of patients undergoing coronary artery bypass grafting, the use of different positive-end expiratory pressure levels before extubation did not affect gas exchange or oxygen therapy utilization in the first 6 h after endotracheal tube removal.

  13. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    Science.gov (United States)

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  14. Value and limitations of transpulmonary pressure calculations during intra-abdominal hypertension.

    Science.gov (United States)

    Cortes-Puentes, Gustavo A; Gard, Kenneth E; Adams, Alexander B; Faltesek, Katherine A; Anderson, Christopher P; Dries, David J; Marini, John J

    2013-08-01

    To clarify the effect of progressively increasing intra-abdominal pressure on esophageal pressure, transpulmonary pressure, and functional residual capacity. Controlled application of increased intra-abdominal pressure at two positive end-expiratory pressure levels (1 and 10 cm H2O) in an anesthetized porcine model of controlled ventilation. Large animal laboratory of a university-affiliated hospital. Eleven deeply anesthetized swine (weight 46.2 ± 6.2 kg). Air-regulated intra-abdominal hypertension (0-25 mm Hg). Esophageal pressure, tidal compliance, bladder pressure, and end-expiratory lung aeration by gas dilution. Functional residual capacity was significantly reduced by increasing intra-abdominal pressure at both positive end-expiratory pressure levels (p ≤ 0.0001) without corresponding changes of end-expiratory esophageal pressure. Above intra-abdominal pressure 5 mm Hg, plateau airway pressure increased linearly by ~ 50% of the applied intra-abdominal pressure value, associated with commensurate changes of esophageal pressure. With tidal volume held constant, negligible changes occurred in transpulmonary pressure due to intra-abdominal pressure. Driving pressures calculated from airway pressures alone (plateau airway pressure--positive end-expiratory pressure) did not equate to those computed from transpulmonary pressure (tidal changes in transpulmonary pressure). Increasing positive end-expiratory pressure shifted the predominantly negative end-expiratory transpulmonary pressure at positive end-expiratory pressure 1 cm H2O (mean -3.5 ± 0.4 cm H2O) into the positive range at positive end-expiratory pressure 10 cm H2O (mean 0.58 ± 1.2 cm H2O). Despite its insensitivity to changes in functional residual capacity, measuring transpulmonary pressure may be helpful in explaining how different levels of positive end-expiratory pressure influence recruitment and collapse during tidal ventilation in the presence of increased intra-abdominal pressure and in

  15. Effect of Training Frequency on Maximum Expiratory Pressure

    Science.gov (United States)

    Anand, Supraja; El-Bashiti, Nour; Sapienza, Christine

    2012-01-01

    Purpose: To determine the effects of expiratory muscle strength training (EMST) frequency on maximum expiratory pressure (MEP). Method: We assigned 12 healthy participants to 2 groups of training frequency (3 days per week and 5 days per week). They completed a 4-week training program on an EMST trainer (Aspire Products, LLC). MEP was the primary…

  16. Thoracoabdominal mobility evaluation by photogrammetry in newborns after expiratory flow increase technique

    Directory of Open Access Journals (Sweden)

    Júlia Isabel de Araújo Guerra

    Full Text Available Abstract Introduction: Expiratory flow increase is a maneuver of respiratory physical therapy that promotes flow direction to the upper airways however, when applied in newborns, it may result in changes of thoracoabdominal mobility. Objective: To evaluate the thoracoabdominal mobility by photogrammetry in newborns after expiratory flow increase technique. Methods: Experimental blind study performed with newborns in supine position on a support table with upper limbs flexed, abducted and externally rotated and hip flexed at 110°. Adhesive markers were allocated for geometric delimitation of the thoracoabdominal compartment and expiratory flow increase technique was performed for 5 minutes with the therapist’s hands on the thorax and abdomen. Newborns were filmed before and after the maneuver and the frames were analyzed in AutoCAD® software by a blinded investigator at the time of the procedure. The largest and the smallest thoracoabdominal area were expressed in cm2 and the mean values were compared between two moments (pre and post maneuver by paired t test. Results: Twenty newborns with a mean age of 39 weeks were included. Before the maneuver, thoracoabdominal area was 56.1 cm2 during expiration and 59.7 cm2 during inspiration, and after the maneuver the value was 56.2 cm2 during expiration and 59.8 cm2 during inspiration, with no statistical difference between before and after (p = 0.97, p = 0.92, respectively. Conclusion: Results demonstrate that expiratory flow increase technique does not seem to change thoracoabdominal mobility of healthy newborns.

  17. Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Hast, J.; Heussel, C.P.; Mildenberger, P.; Thelen, M.; Schlegel, J.

    2000-01-01

    This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal - not diffuse - airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six of 26 patients with restrictive lung function impairment exhibited focal airtrapping (mean score 2.4), whereas only 72 of 98 (74 %) patients with obstruction did (mean score 1.5; p < 0.05). Fifty-eight of 70 (83 %) patients with normal lung function (mean score 1.8) and 19 of 23 (83 %) patients with mixed impairment (mean score 1.8) had focal airtrapping. Focal airtrapping showed negative correlations with static lung volumes (-0.27 to -0.37; p < 0.001) in all patients and moderate positive correlations with dynamic parameters (0.3-0.4; p < 0.001) in patients with obstruction. No significant correlations were found with age, gender, and blood gas analysis. Visual assessment of focal - not diffuse - airtrapping at expiratory high-resolution CT does not correlate with physiological evidence of obstruction as derived from pulmonary function tests since the perception of focal airtrapping requires an adequate expiratory increase in lung density. (orig.)

  18. The Clinical Utilisation of Respiratory Elastance Software (CURE Soft): a bedside software for real-time respiratory mechanics monitoring and mechanical ventilation management.

    Science.gov (United States)

    Szlavecz, Akos; Chiew, Yeong Shiong; Redmond, Daniel; Beatson, Alex; Glassenbury, Daniel; Corbett, Simon; Major, Vincent; Pretty, Christopher; Shaw, Geoffrey M; Benyo, Balazs; Desaive, Thomas; Chase, J Geoffrey

    2014-09-30

    Real-time patient respiratory mechanics estimation can be used to guide mechanical ventilation settings, particularly, positive end-expiratory pressure (PEEP). This work presents a software, Clinical Utilisation of Respiratory Elastance (CURE Soft), using a time-varying respiratory elastance model to offer this ability to aid in mechanical ventilation treatment. CURE Soft is a desktop application developed in JAVA. It has two modes of operation, 1) Online real-time monitoring decision support and, 2) Offline for user education purposes, auditing, or reviewing patient care. The CURE Soft has been tested in mechanically ventilated patients with respiratory failure. The clinical protocol, software testing and use of the data were approved by the New Zealand Southern Regional Ethics Committee. Using CURE Soft, patient's respiratory mechanics response to treatment and clinical protocol were monitored. Results showed that the patient's respiratory elastance (Stiffness) changed with the use of muscle relaxants, and responded differently to ventilator settings. This information can be used to guide mechanical ventilation therapy and titrate optimal ventilator PEEP. CURE Soft enables real-time calculation of model-based respiratory mechanics for mechanically ventilated patients. Results showed that the system is able to provide detailed, previously unavailable information on patient-specific respiratory mechanics and response to therapy in real-time. The additional insight available to clinicians provides the potential for improved decision-making, and thus improved patient care and outcomes.

  19. A novel mechanical lung model of pulmonary diseases to assist with teaching and training

    Directory of Open Access Journals (Sweden)

    Shaw Geoffrey M

    2006-08-01

    Full Text Available Abstract Background A design concept of low-cost, simple, fully mechanical model of a mechanically ventilated, passively breathing lung is developed. An example model is built to simulate a patient under mechanical ventilation with accurate volumes and compliances, while connected directly to a ventilator. Methods The lung is modelled with multiple units, represented by rubber bellows, with adjustable weights placed on bellows to simulate compartments of different superimposed pressure and compliance, as well as different levels of lung disease, such as Acute Respiratory Distress Syndrome (ARDS. The model was directly connected to a ventilator and the resulting pressure volume curves recorded. Results The model effectively captures the fundamental lung dynamics for a variety of conditions, and showed the effects of different ventilator settings. It was particularly effective at showing the impact of Positive End Expiratory Pressure (PEEP therapy on lung recruitment to improve oxygenation, a particulary difficult dynamic to capture. Conclusion Application of PEEP therapy is difficult to teach and demonstrate clearly. Therefore, the model provide opportunity to train, teach, and aid further understanding of lung mechanics and the treatment of lung diseases in critical care, such as ARDS and asthma. Finally, the model's pure mechanical nature and accurate lung volumes mean that all results are both clearly visible and thus intuitively simple to grasp.

  20. Expiratory timing in obstructive sleep apnoeas.

    Science.gov (United States)

    Cibella, F; Marrone, O; Sanci, S; Bellia, V; Bonsignore, G

    1990-03-01

    Diaphragmatic electromyogram was recorded during NREM sleep in 4 patients affected by obstructive sleep apnoea (OSA) syndrome in order to evaluate the behaviour of expiratory time (TE) in the course of the obstructive apnoea-ventilation cycle. The two components of TE, i.e. time of post-inspiratory inspiratory activity (TPIIA) and time of expiratory phase 2 (TE2) were separately analysed. TPIIA showed a short duration, with only minor variations, within the apnoea, while its duration was more variable and longer in the interapnoeic periods: the longest TPIIA values were associated with the highest inspiratory volumes in the same breaths. This behaviour seemed regulated according to the need of a more or less effective expiratory flow braking, probably as a result of pulmonary stretch receptors discharge. Conversely TE2 showed a continuous gradual modulation, progressively increasing in the pre-apnoeic period, decreasing during the apnoea and increasing in the post-apnoeic period: these TE2 variations seemed related to oscillations in chemical drive. These data show that TE in the obstructive apnoea-ventilation cycle results from a different modulation in its two components and suggest that both mechanical and chemical influences play a role in its overall duration.

  1. Hemodynamic differences between continual positive and two types of negative pressure ventilation.

    Science.gov (United States)

    Lockhat, D; Langleben, D; Zidulka, A

    1992-09-01

    In seven anesthetized dogs, ventilated with matching lung volumes, tidal volumes, and respiratory rates, we compared the effects on cardiac output (CO), arterial venous oxygen saturation difference (SaO2 - SVO2), and femoral and inferior vena cava pressure (1) intermittent positive pressure ventilation with positive end-expiratory pressure (CPPV); (2) iron-lung ventilation with negative end-expiratory pressure (ILV-NEEP); (3) grid and wrap ventilation with NEEP applied to the thorax and upper abdomen (G&W-NEEP). The values of CO and SaO2 - SVO2 with ILV-NEEP were similar to those with CPPV. However, with G&W-NEEP as compared with ILV-NEEP, mean CO was greater (2.9 versus 2.6 L/min, p = 0.02) and mean (SaO2 - SVO2) was lower (26.6% versus 28.3%, p = NS). Mean PFEM-IVC was higher with G&W-NEEP than with the other types of ventilation. We conclude that (1) ILV-NEEP is hemodynamically equivalent to CPPV and (2) G&W-NEEP has less adverse hemodynamic consequences. has less adverse hemodynamic consequences.

  2. The effect of low level laser therapy on ventilator-induced lung injury in mice (Conference Presentation)

    Science.gov (United States)

    Szabari, Margit V.; Miller, Alyssa J.; Hariri, Lida P.; Hamblin, Michael R.; Musch, Guido; Stroh, Helene; Suter, Melissa J.

    2016-03-01

    Although mechanical ventilation (MV) is necessary to support gas exchange in critically ill patients, it can contribute to the development of lung injury and multiple organ dysfunction. It is known that high tidal volume (Vt) MV can cause ventilator-induced lung injury (VILI) in healthy lungs and increase the mortality of patients with Acute Respiratory Distress Syndrome. Low level laser therapy (LLLT) has demonstrated to have anti-inflammatory effects. We investigated whether LLLT could alleviate inflammation from injurious MV in mice. Adult mice were assigned to 2 groups: VILI+LLLT group (3 h of injurious MV: Vt=25-30 ml/kg, respiratory rate (RR)=50/min, positive end-expiratory pressure (PEEP)=0 cmH20, followed by 3 h of protective MV: Vt=9 ml/kg, RR=140/min, PEEP=2 cmH20) and VILI+no LLLT group. LLLT was applied during the first 30 min of the MV (810 nm LED system, 5 J/cm2, 1 cm above the chest). Respiratory impedance was measured in vivo with forced oscillation technique and lung mechanics were calculated by fitting the constant phase model. At the end of the MV, bronchoalveolar lavage (BAL) was performed and inflammatory cells counted. Lungs were removed en-bloc and fixed for histological evaluation. We hypothesize that LLLT can reduce lung injury and inflammation from VILI. This therapy could be translated into clinical practice, where it can potentially improve outcomes in patients requiring mechanical ventilation in the operating room or in the intensive care units.

  3. Peak Expiratory Flow Rate In Cigarette Smokers | Ukoli | Highland ...

    African Journals Online (AJOL)

    Objective: To compare lung function between smokers and non-smokers using Peak Expiratory Flow Rate (PEFR). Methods: This study examines the peak expiratory flow rate (PEFR) of three hundred and forty cigarette smokers, age and sex-matched with PEFR of equal number of non-smokers. Results: The mean PEFR of ...

  4. Ventilation area measured with eit in order to optimize peep settings in mechanically ventilated patients

    NARCIS (Netherlands)

    Blankman, P; Groot Jebbink, E; Preis, C; Bikker, I.; Gommers, D.

    2012-01-01

    INTRODUCTION. Electrical Impedance Tomography (EIT) is a non-invasive imaging technique, which can be used to visualize ventilation. Ventilation will be measured by impedance changes due to ventilation. OBJECTIVES. The aim of this study was to optimize PEEP settings based on the ventilation area of

  5. Different Techniques of Respiratory Support Do Not Significantly Affect Gas Exchange during Cardiopulmonary Resuscitation in a Newborn Piglet Model.

    Science.gov (United States)

    Mendler, Marc R; Maurer, Miriam; Hassan, Mohammad A; Huang, Li; Waitz, Markus; Mayer, Benjamin; Hummler, Helmut D

    2015-01-01

    There are no evidence-based recommendations on the use of different techniques of respiratory support and chest compressions (CC) during neonatal cardiopulmonary resuscitation (CPR). We studied the short-term effects of different ventilatory support strategies along with CC representing clinical practice on gas exchange [arterial oxygen saturation (SaO2), arterial partial pressure of oxygen (PaO2) and arterial partial pressure of carbon dioxide (PaCO2)], hemodynamics and cerebral oxygenation. We hypothesized that in newborn piglets with cardiac arrest, use of a T-piece resuscitator (TPR) providing positive end-expiratory pressure (PEEP) improves gas exchange as measured by SaO2 during CPR as compared to using a self-inflating bag (SIB) without PEEP. Furthermore, we explored the effects of a mechanical ventilator without synchrony to CC. Thirty newborn piglets with asystole were randomized into three groups and resuscitated for 20 min [fraction of inspired oxygen (FiO2) = 0.21 for 10 min and 1.0 thereafter]. Group 1 received ventilation using a TPR [peak inspiratory pressure (PIP)/PEEP of 20/5 cm H2O, rate 30/min] with inflations interposed between CC (3:1 ratio). Group 2 received ventilation using a SIB (PIP of 20 cm H2O without PEEP, rate 30/min) with inflations interposed between CC (3:1 ratio). Group 3 received ventilation using a mechanical ventilator (PIP/PEEP of 20/5 cm H2O, rate 30/min). CC were applied with a rate of 120/min without synchrony to inflations. We found no significant differences in SaO2 between the three groups. However, there was a trend toward a higher SaO2 [TPR: 28.0% (22.3-40.0); SIB: 23.7% (13.4-52.3); ventilator: 44.1% (39.2-54.3); median (interquartile range)] and a lower PaCO2 [TPR: 95.6 mm Hg (82.1-113.6); SIB: 100.8 mm Hg (83.0-108.0); ventilator: 74.1 mm Hg (68.5-83.1); median (interquartile range)] in the mechanical ventilator group. We found no significant effect on gas exchange using different respiratory support strategies

  6. Dangerous Pressurization and Inappropriate Alarms during Water Occlusion of the Expiratory Circuit of Commonly Used Infant Ventilators.

    Directory of Open Access Journals (Sweden)

    Murray Hinder

    Full Text Available Non-invasive continuous positive airways pressure is commonly a primary respiratory therapy delivered via multi-purpose ventilators in premature newborns. Expiratory limb occlusion due to water accumulation or 'rainout' from gas humidification is a frequent issue. A case of expiratory limb occlusion due to rainout causing unexpected and excessive repetitive airway pressurisation in a Draeger VN500 prompted a systematic bench test examination of currently available ventilators.To assess neonatal ventilator response to partial or complete expiratory limb occlusion when set to non-invasive continuous positive airway pressure mode.Seven commercially available neonatal ventilators connected to a test lung using a standard infant humidifier circuit with partial and/or complete expiratory limb occlusion were examined in a bench test study. Each ventilator was set to deliver 6 cmH2O in non-invasive mode and respiratory mechanics data for 75%, 80% and 100% occlusion were collected.Several ventilators responded inappropriately with complete occlusion by cyclical pressurisation/depressurisation to peak pressures of between 19·4 and 64·6 cm H2O at rates varying between 2 to 77 inflations per minute. Tidal volumes varied between 10·1 and 24·3mL. Alarm responses varied from 'specific' (tube occluded to 'ambiguous' (Safety valve open. Carefusion Avea responded by continuing to provide the set distending pressure and displaying an appropriate alarm message. Draeger Babylog 8000 did not alarm with partial occlusions and incorrectly displayed airways pressure at 6·1cmH2O compared to the measured values of 13cmH2O.This study found a potential for significant adverse ventilator response due to complete or near complete expiratory limb occlusion in CPAP mode.

  7. Superoxide dismutase levels and peak expiratory flow in asthmatic children

    Directory of Open Access Journals (Sweden)

    Arie Kurniasih

    2016-11-01

    Full Text Available Background Asthma is a chronic inflammatory process which involve variety of cells such as inflammatory mediators, reactive oxygen species (ROS, and cytokines. The inflammatory process would be exacerbated in the presence of oxidative stress. Superoxide dismutase (SOD is the first important enzyme to protect the respiratory tract against oxidative stress. The decreased of SOD has a correlation with increased of airway obstruction and bronchospasm. Objective To assess for a correlation between superoxide dismutase (SOD levels and peak expiratory flow, as well as to determine the impact of SOD levels for predicting asthma attacks. Methods We conducted a prospective cohort study at Dr. Sardjito Hospital, Yogyakarta, between February and April 2011 involving asthmatic children aged 5-18 years. Subjects’ serum SOD levels and peak expiratory flow were measured at the same time point. We then performed a prospective study following up on the same subjects to find out if they had a recurrent asthma attack within one month of the tests. We also reassessed their peak expiratory flow one month after blood specimens were obtained. Results Thirty-nine patients were enrolled in this study. There was no significant correlation between SOD level and peak expiratory flow [r=0.289; 95%CI -0.025 to 0.47; P=0.074]. However, older age was significantly associated with higher peak expiratory flow (=0.5; 95%CI 3.10 to 11.57; P=0.01. Lower levels of SOD increased the risk of asthma attacks in a month following the initial measurements (RR=5.5; 95%CI 1.6 to 18.9; P=0.009. Conclusion Superoxide dismutase (SOD level is not significantly associated with peak expiratory flow. However, we find a relationship between older age and higher peak expiratory flow and a relationship between lower SOD levels and risk of asthma attacks within one month following the tests.

  8. Physiological techniques for detecting expiratory flow limitation during tidal breathing

    Directory of Open Access Journals (Sweden)

    N.G. Koulouris

    2011-09-01

    Full Text Available Patients with severe chronic obstructive pulmonary disease (COPD often exhale along the same flow–volume curve during quiet breathing as they do during the forced expiratory vital capacity manoeuvre, and this has been taken as an indicator of expiratory flow limitation at rest (EFLT. Therefore, EFLT, namely attainment of maximal expiratory flow during tidal expiration, occurs when an increase in transpulmonary pressure causes no increase in expiratory flow. EFLT leads to small airway injury and promotes dynamic pulmonary hyperinflation, with concurrent dyspnoea and exercise limitation. In fact, EFLT occurs commonly in COPD patients (mainly in Global Initiative for Chronic Obstructive Lung Disease III and IV stage, in whom the latter symptoms are common, but is not exclusive to COPD, since it can also be detected in other pulmonary and nonpulmonary diseases like asthma, acute respiratory distress syndrome, heart failure and obesity, etc. The existing up to date physiological techniques of assessing EFLT are reviewed in the present work. Among the currently available techniques, the negative expiratory pressure has been validated in a wide variety of settings and disorders. Consequently, it should be regarded as a simple, noninvasive, practical and accurate new technique.

  9. Single-Lung Transplant Results in Position Dependent Changes in Regional Ventilation: An Observational Case Series Using Electrical Impedance Tomography

    Directory of Open Access Journals (Sweden)

    Kollengode Ramanathan

    2016-01-01

    Full Text Available Background. Lung transplantation is the optimal treatment for end stage lung disease. Donor shortage necessitates single-lung transplants (SLT, yet minimal data exists regarding regional ventilation in diseased versus transplanted lung measured by Electrical Impedance Tomography (EIT. Method. We aimed to determine regional ventilation in six SLT outpatients using EIT. We assessed end expiratory volume and tidal volumes. End expiratory lung impedance (EELI and Global Tidal Variation of Impedance were assessed in supine, right lateral, left lateral, sitting, and standing positions in transplanted and diseased lungs. A mixed model with random intercept per subject was used for statistical analysis. Results. EELI was significantly altered between diseased and transplanted lungs whilst lying on right and left side. One patient demonstrated pendelluft between lungs and was therefore excluded for further comparison of tidal variation. Tidal variation was significantly higher in the transplanted lung for the remaining five patients in all positions, except when lying on the right side. Conclusion. Ventilation to transplanted lung is better than diseased lung, especially in lateral positions. Positioning in patients with active unilateral lung pathologies will be implicated. This is the first study demonstrating changes in regional ventilation, associated with changes of position between transplanted and diseased lung.

  10. Lung Transcriptomics during Protective Ventilatory Support in Sepsis-Induced Acute Lung Injury.

    Directory of Open Access Journals (Sweden)

    Marialbert Acosta-Herrera

    Full Text Available Acute lung injury (ALI is a severe inflammatory process of the lung. The only proven life-saving support is mechanical ventilation (MV using low tidal volumes (LVT plus moderate to high levels of positive end-expiratory pressure (PEEP. However, it is currently unknown how they exert the protective effects. To identify the molecular mechanisms modulated by protective MV, this study reports transcriptomic analyses based on microarray and microRNA sequencing in lung tissues from a clinically relevant animal model of sepsis-induced ALI. Sepsis was induced by cecal ligation and puncture (CLP in male Sprague-Dawley rats. At 24 hours post-CLP, septic animals were randomized to three ventilatory strategies: spontaneous breathing, LVT (6 ml/kg plus 10 cmH2O PEEP and high tidal volume (HVT, 20 ml/kg plus 2 cmH2O PEEP. Healthy, non-septic, non-ventilated animals served as controls. After 4 hours of ventilation, lung samples were obtained for histological examination and gene expression analysis using microarray and microRNA sequencing. Validations were assessed using parallel analyses on existing publicly available genome-wide association study findings and transcriptomic human data. The catalogue of deregulated processes differed among experimental groups. The 'response to microorganisms' was the most prominent biological process in septic, non-ventilated and in HVT animals. Unexpectedly, the 'neuron projection morphogenesis' process was one of the most significantly deregulated in LVT. Further support for the key role of the latter process was obtained by microRNA studies, as four species targeting many of its genes (Mir-27a, Mir-103, Mir-17-5p and Mir-130a were found deregulated. Additional analyses revealed 'VEGF signaling' as a central underlying response mechanism to all the septic groups (spontaneously breathing or mechanically ventilated. Based on this data, we conclude that a co-deregulation of 'VEGF signaling' along with 'neuron projection

  11. Lung Transcriptomics during Protective Ventilatory Support in Sepsis-Induced Acute Lung Injury

    Science.gov (United States)

    Acosta-Herrera, Marialbert; Lorenzo-Diaz, Fabian; Pino-Yanes, Maria; Corrales, Almudena; Valladares, Francisco; Klassert, Tilman E.; Valladares, Basilio; Slevogt, Hortense; Ma, Shwu-Fan

    2015-01-01

    Acute lung injury (ALI) is a severe inflammatory process of the lung. The only proven life-saving support is mechanical ventilation (MV) using low tidal volumes (LVT) plus moderate to high levels of positive end-expiratory pressure (PEEP). However, it is currently unknown how they exert the protective effects. To identify the molecular mechanisms modulated by protective MV, this study reports transcriptomic analyses based on microarray and microRNA sequencing in lung tissues from a clinically relevant animal model of sepsis-induced ALI. Sepsis was induced by cecal ligation and puncture (CLP) in male Sprague-Dawley rats. At 24 hours post-CLP, septic animals were randomized to three ventilatory strategies: spontaneous breathing, LVT (6 ml/kg) plus 10 cmH2O PEEP and high tidal volume (HVT, 20 ml/kg) plus 2 cmH2O PEEP. Healthy, non-septic, non-ventilated animals served as controls. After 4 hours of ventilation, lung samples were obtained for histological examination and gene expression analysis using microarray and microRNA sequencing. Validations were assessed using parallel analyses on existing publicly available genome-wide association study findings and transcriptomic human data. The catalogue of deregulated processes differed among experimental groups. The ‘response to microorganisms’ was the most prominent biological process in septic, non-ventilated and in HVT animals. Unexpectedly, the ‘neuron projection morphogenesis’ process was one of the most significantly deregulated in LVT. Further support for the key role of the latter process was obtained by microRNA studies, as four species targeting many of its genes (Mir-27a, Mir-103, Mir-17-5p and Mir-130a) were found deregulated. Additional analyses revealed 'VEGF signaling' as a central underlying response mechanism to all the septic groups (spontaneously breathing or mechanically ventilated). Based on this data, we conclude that a co-deregulation of 'VEGF signaling' along with 'neuron projection

  12. What's in a name? Expiratory tracheal narrowing in adults explained

    International Nuclear Information System (INIS)

    Leong, P.; Bardin, P.G.; Lau, K.K.

    2013-01-01

    Tracheomalacia, tracheobronchomalacia, and excessive dynamic airway collapse are all terms used to describe tracheal narrowing in expiration. The first two describe luminal reduction from cartilage softening and the latter refers to luminal reduction from exaggerated posterior membrane movement. Expiratory tracheal narrowing is a frequent occurrence that can cause symptoms of airway obstruction, such as dyspnoea, wheeze, and exercise intolerance. The accurate diagnosis and quantification of expiratory tracheal narrowing has important aetiological, therapeutic, and prognostic implications. The reference standard for diagnosis has traditionally been bronchoscopy; however, this method has significant limitations. Expiratory tracheal disorders are readily detected by four-dimensional dynamic volume multidetector computed tomography (4D-CT), an emerging, non-invasive method that will potentially enable detection and quantification of these conditions. This review discusses the morphological forms of expiratory tracheal narrowing and demonstrates the utility of 4D-CT in the diagnosis, quantification, and treatment of these important conditions

  13. Cardiac effects of positive pressure ventilation in ARDS assessed by NT-proBNP, Troponin T and Troponin I

    Directory of Open Access Journals (Sweden)

    Yasser Sadek Nassar

    2013-01-01

    Although the increase in cardiac markers are insignificant, yet they point to the potentially harmful role played by high PEEP, low PH and low PaO2/FiO2 ratio on the heart. Currently, no clinically relevant conclusion can be drawn apart from the recommendation to attempt to lower PEEP and shorten the duration of positive pressure ventilation, even in patients with structurally normal hearts.

  14. Inspiratory and expiratory HRCT findings in healthy smokers' lung

    International Nuclear Information System (INIS)

    Park, Hyeon Seon; Kwak, Byung Kook; Choi, Chi Hoon; Yang, Keun Mung; Lee, Chang Joon; Joo, Dong Il; Kim, Yang Soo

    1998-01-01

    The purpose of this study is to evaluate the lung changes in healthy smokers, as seen on inspiratory and expiratory high-resolution computed tomography (HRCT). Twenty-seven healthy smokers (light smokers, below 20 pack-years, n=16; heavy smokers, above 20 pack-years, n=11) and 25 nonsmokers underwent inspiratory and expiratory HRCT. All healthy smokers had normal pulmonary function and chest radiography. Parenchymal and subpleural micronodules, ground-glass attenuation, centrilobular and paraseptal emphysema, bronchial wall thickening, bronchiectasis and septal line were evaluated on inspiratory scan and by air-trapping on expiratory scan. According to the findings of HRCT, heavy smokers and higher frequency of parenchymal micronodules, ground-glass attenuation, centrilobular and paraseptal emphysema, and air-trapping than nonsmokers and light smokers. (author). 13 refs., 1 tab., 4 figs

  15. Measurement of tidal volume using respiratory ultrasonic plethysmography in anaesthetized, mechanically ventilated horses.

    Science.gov (United States)

    Russold, Elena; Ambrisko, Tamas D; Schramel, Johannes P; Auer, Ulrike; Van Den Hoven, Rene; Moens, Yves P

    2013-01-01

    To compare tidal volume estimations obtained from Respiratory Ultrasonic Plethysmography (RUP) with simultaneous spirometric measurements in anaesthetized, mechanically ventilated horses. Prospective randomized experimental study. Five experimental horses. Five horses were anaesthetized twice (1 week apart) in random order in lateral and in dorsal recumbency. Nine ventilation modes (treatments) were scheduled in random order (each lasting 4 minutes) applying combinations of different tidal volumes (8, 10, 12 mL kg(-1)) and positive end-expiratory pressures (PEEP) (0, 10, 20 cm H(2)O). Baseline ventilation mode (tidal volume=15 mL kg(-1), PEEP=0 cm H(2)O) was applied for 4 minutes between all treatments. Spirometry and RUP data were downloaded to personal computers. Linear regression analyses (RUP versus spirometric tidal volume) were performed using different subsets of data. Additonally RUP was calibrated against spirometry using a regression equation for all RUP signal values (thoracic, abdominal and combined) with all data collectively and also by an individually determined best regression equation (highest R(2)) for each experiment (horse versus recumbency) separately. Agreement between methods was assessed with Bland-Altman analyses. The highest correlation of RUP and spirometric tidal volume (R(2)=0.81) was found with the combined RUP signal in horses in lateral recumbency and ventilated without PEEP. The bias ±2 SD was 0±2.66 L when RUP was calibrated for collective data, but decreased to 0±0.87 L when RUP was calibrated with individual data. A possible use of RUP for tidal volume measurement during IPPV needs individual calibration to obtain limits of agreement within ±20%. © 2012 The Authors. Veterinary Anaesthesia and Analgesia. © 2012 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.

  16. Pneumoperitoneum deteriorates intratidal respiratory system mechanics: an observational study in lung-healthy patients.

    Science.gov (United States)

    Wirth, Steffen; Biesemann, Andreas; Spaeth, Johannes; Schumann, Stefan

    2017-02-01

    Pneumoperitoneum during laparoscopic surgery leads to atelectasis and impairment of oxygenation. Positive end-expiratory pressure (PEEP) is supposed to counteract atelectasis. We hypothesized that the derecruiting effects of pneumoperitoneum would deteriorate the intratidal compliance profile in patients undergoing laparoscopic surgery. In 30 adult patients scheduled for surgery with pneumoperitoneum, respiratory variables were measured during mechanical ventilation. We calculated the dynamic compliance of the respiratory system (C RS ) and the intratidal volume-dependent C RS curve using the gliding-SLICE method. The C RS curve was then classified in terms of indicating intratidal recruitment/derecruitment (increasing profile) and overdistension (decreasing profile). During the surgical interventions, the PEEP level was maintained nearly constant at 7 cm H 2 O. Data are expressed as mean [confidence interval]. Baseline C RS was 60 [54-67] mL cm H 2 O -1 . Application of pneumoperitoneum decreased C RS to 40 [37-43] mL cm H 2 O -1 which partially recovered to 54 [50-59] mL cm H 2 O -1 (P < 0.001) after removal but remained below the value measured before pneumoperitoneum (P < 0.001). Baseline compliance profiles indicated intratidal recruitment/derecruitment in 48 % patients. After induction of pneumoperitoneum, intratidal recruitment/derecruitment was indicated in 93 % patients (P < 0.01), and after removal intratidal recruitment/derecruitment was indicated in 59 % patients. Compliance profiles showing overdistension were not observed. Analyses of the intratidal compliance profiles reveal that pneumoperitoneum during laparoscopic surgery causes intratidal recruitment/derecruitment which partly persists after its removal. The analysis of the intratidal volume-dependent C RS profiles could be used to guide intraoperative PEEP adjustments during elevated intraabdominal pressure.

  17. Use of tidal breathing curves for evaluating expiratory airway obstruction in infants.

    Science.gov (United States)

    Hevroni, Avigdor; Goldman, Aliza; Blank-Brachfeld, Miriam; Abu Ahmad, Wiessam; Ben-Dov, Lior; Springer, Chaim

    2018-01-15

    To evaluate tidal breathing (TB) flow-volume and flow-time curves for identification of expiratory airway obstruction in infants. Pulmonary function tests were analyzed retrospectively in 156 infants aged 3-24 months with persistent or recurrent respiratory complaints. Parameters derived from TB curves were compared to maximal expiratory flow at functional residual capacity ([Formula: see text]maxFRC) measured by rapid thoracoabdominal compression technique. Analyzed parameters were: inspiratory time (t I ), expiratory time (t E ), tidal volume, peak tidal expiratory flow (PTEF), time to peak tidal expiratory flow (t PTEF ), expiratory flow when 50% and 25% of tidal volume remains in the lungs (FEF 50 , FEF 25 , respectively), and the ratios t PTEF /t E , t I /t E , FEF 50 /PTEF, and FEF 25 /PTEF. Statistical comparisons between flow indices and TB parameters were performed using mean squared error and Pearson's sample correlation coefficient. The study population was also divided into two groups based on severity of expiratory obstruction (above or below z-score for [Formula: see text]maxFRC of -2) to generate receiver operating characteristic (ROC) curves and calculate discriminatory values between the groups. TB parameters that were best correlated to [Formula: see text]maxFRC were: t PTEF /t E , FEF 50 /PTEF, and FEF 25 /PTEF, with r = 0.61, 0.67, 0.65, respectively (p < 0.0001 for all). ROC curves for FEF 50 /PTEF, FEF 25 /PTEF and t PTEF /t E showed areas under the curve of 0.813, 0.797, and 0.796, respectively. Cutoff value z-scores of -0.35, -0.34, and -0.43 for these three parameters, respectively, showed an 86% negative predictive value for severe airway obstructions. TB curves can assist in ruling out severe expiratory airway obstruction in infants.

  18. Evaluation of Pressure Generated by Resistors From Different Positive Expiratory Pressure Devices.

    Science.gov (United States)

    Fagevik Olsén, Monika; Carlsson, Maria; Olsén, Erik; Westerdahl, Elisabeth

    2015-10-01

    Breathing exercises with positive expiratory pressure (PEP) are used to improve pulmonary function and airway clearance. Different PEP devices are available, but there have been no studies that describe the pressure generated by different resistors. The purpose of this study was to compare pressures generated from the proprietary resistor components of 4 commercial flow-dependent PEP valves with all other parameters kept constant. Resistors from 4 flow-regulated PEP devices (Pep/Rmt system, Wellspect HealthCare; Pipe P breathing exerciser, Koo Medical Equipment; Mini-PEP, Philips Respironics [including resistors by Rüsch]; and 15-mm endo-adapter, VBM Medizintechnik) were tested randomly by a blinded tester at constant flows of 10 and 18 L/min from an external gas system. All resistors were tested 3 times. Resistors with a similar diameter produced statistically significant different pressures at the same flow. The differences were smaller when the flow was 10 L/min compared with 18 L/min. The differences were also smaller when the diameter of the resistor was increased. The pressures produced by the 4 resistors of the same size were all significantly different when measuring 1.5- and 2.0-mm resistors at a flow of 10 L/min and 2.0-mm resistors at a flow of 18 L/min (P < .001). There were no significant differences between any of the resistors when testing sizes of 4.5 and 5.0 mm at either flow. The Mini-PEP and adapter resistors gave the highest pressures. Pressures generated by the different proprietary resistor components of 4 commercial PEP devices were not comparable, even though the diameter of the resistors is reported to be the same. The pressures generated were significantly different, particularly when using small-diameter resistors at a high flow. Therefore, the resistors may not be interchangeable. This is important information for clinicians, particularly when considering PEP for patients who do not tolerate higher pressures. Copyright © 2015 by

  19. A Short Period of Ventilation without Perfusion Seems to Reduce Atelectasis without Harming the Lungs during Ex Vivo Lung Perfusion

    Directory of Open Access Journals (Sweden)

    Sandra Lindstedt

    2013-01-01

    Full Text Available To evaluate the lung function of donors after circulatory deaths (DCDs, ex vivo lung perfusion (EVLP has been shown to be a valuable method. We present modified EVLP where lung atelectasis is removed, while the lung perfusion is temporarily shut down. Twelve pigs were randomized into two groups: modified EVLP and conventional EVLP. When the lungs had reached 37°C in the EVLP circuit, lung perfusion was temporarily shut down in the modified EVLP group, and positive end-expiratory pressure (PEEP was increased to 10 cm H2O for 10 minutes. In the conventional EVLP group, PEEP was increased to 10 cm H2O for 10 minutes with unchanged lung perfusion. In the modified EVLP group, the arterial oxygen partial pressure (PaO2 was 18.5 ± 7.0 kPa before and 64.5 ± 6.0 kPa after the maneuver (P<0.001. In the conventional EVLP group, the PaO2 was 16.8 ± 3.1 kPa and 46.8 ± 2.7 kPa after the maneuver (P<0.01; P<0.01. In the modified EVLP group, the pulmonary graft weight was unchanged, while in the conventional EVLP group, the pulmonary graft weight was significantly increased. Modified EVLP with normoventilation of the lungs without ongoing lung perfusion for 10 minutes may eliminate atelectasis almost completely without harming the lungs.

  20. Implementation of a Goal-Directed Mechanical Ventilation Order Set Driven by Respiratory Therapists Improves Compliance With Best Practices for Mechanical Ventilation.

    Science.gov (United States)

    Radosevich, Misty A; Wanta, Brendan T; Meyer, Todd J; Weber, Verlin W; Brown, Daniel R; Smischney, Nathan J; Diedrich, Daniel A

    2017-01-01

    Data regarding best practices for ventilator management strategies that improve outcomes in acute respiratory distress syndrome (ARDS) are readily available. However, little is known regarding processes to ensure compliance with these strategies. We developed a goal-directed mechanical ventilation order set that included physician-specified lung-protective ventilation and oxygenation goals to be implemented by respiratory therapists (RTs). We sought as a primary outcome to determine whether an RT-driven order set with predefined oxygenation and ventilation goals could be implemented and associated with improved adherence with best practice. We evaluated 1302 patients undergoing invasive mechanical ventilation (1693 separate episodes of invasive mechanical ventilation) prior to and after institution of a standardized, goal-directed mechanical ventilation order set using a controlled before-and-after study design. Patient-specific goals for oxygenation partial pressure of oxygen in arterial blood (Pao 2 ), ARDS Network [Net] positive end-expiratory pressure [PEEP]/fraction of inspired oxygen [Fio 2 ] table use) and ventilation (pH, partial pressure of carbon dioxide) were selected by prescribers and implemented by RTs. Compliance with the new mechanical ventilation order set was high: 88.2% compliance versus 3.8% before implementation of the order set ( P mechanical ventilation, intensive care unit (ICU) length of stay, and in-hospital or ICU mortality. A standardized best practice mechanical ventilation order set can be implemented by a multidisciplinary team and is associated with improved compliance to written orders and adherence to the ARDSNet PEEP/Fio 2 table.

  1. Toward improved surveillance: the impact of ventilator-associated complications on length of stay and antibiotic use in patients in intensive care units.

    Science.gov (United States)

    Hayashi, Yoshiro; Morisawa, Kenichiro; Klompas, Michael; Jones, Mark; Bandeshe, Hiran; Boots, Robert; Lipman, Jeffrey; Paterson, David L

    2013-02-01

    Hospitals and quality improvement agencies are vigorously focusing on reducing rates of hospital-acquired infection. Ventilator-associated pneumonia (VAP) is notoriously difficult to diagnose and surveillance is thwarted by the subjectivity of many components of the surveillance definition. Alternative surveillance strategies are needed. Ventilator-associated complications (VAC) is a simple, objective measure of respiratory deterioration. VAC is defined by increases in fraction of inspired oxygen (FiO(2)) by ≥ 15% or positive end-expiratory pressure (PEEP) by ≥ 2.5 cm H(2)O lasting ≥ 2 days after stable or decreasing FiO(2) or PEEP lasting ≥ 2 days. We retrospectively assessed patients on mechanical ventilation for ≥ 48 hours in our study intensive care unit (ICU) using electronic medical record data. We analyzed the association between VAC and clinical diagnoses, ICU length of stay, duration of mechanical ventilation, antibiotic use, and mortality. We assessed 153 patients with VAC and 390 without VAC. VAC events were associated with significantly increased ICU length of stay, duration of mechanical ventilation, and consumption of broad-spectrum antibiotics but not with longer hospital stays or ICU mortality. Surveillance for VAP is subjective and labor intensive. VAC is an objective measure which can be readily obtained from electronic records. It is associated with adverse outcomes and increased broad-spectrum antibiotic usage. VAC may be a useful surveillance tool. The utility of VAC prevention bundles merits assessment.

  2. Protective mechanical ventilation, why use it?

    Science.gov (United States)

    Seiberlich, Emerson; Santana, Jonas Alves; Chaves, Renata de Andrade; Seiberlich, Raquel Carvalho

    2011-01-01

    Mechanical ventilation (MV) strategies have been modified over the last decades with a tendency for increasingly lower tidal volumes (VT). However, in patients without acute lung injury (ALI) or acute respiratory distress syndrome (ARDS) the use of high VTs is still very common. Retrospective studies suggest that this practice can be related to mechanical ventilation-associated ALI. The objective of this review is to search for evidence to guide protective MV in patients with healthy lungs and to suggest strategies to properly ventilate lungs with ALI/ARDS. A review based on the main articles that focus on the use of strategies of mechanical ventilation was performed. Consistent studies to determine which would be the best way to ventilate a patient with healthy lungs are lacking. Expert recommendations and current evidence presented in this article indicate that the use of a VT lower than 10 mL.kg(-1), associated with positive end-expiratory pressure (PEEP) ≥ 5 cmH(2)O without exceeding a pressure plateau of 15 to 20 cmH(2)O could minimize alveolar stretching at the end of inspiration and avoid possible inflammation or alveolar collapse. Copyright © 2011 Elsevier Editora Ltda. All rights reserved.

  3. Incidence of tracheobronchomalacia associated with pulmonary emphysema. Detection with paired inspiratory-expiratory multidetector computed tomography using a low-dose technique

    International Nuclear Information System (INIS)

    Inoue, Masanori; Hasegawa, Ichiro; Nakano, Keiko; Yamaguchi, Kazuhiro; Kuribayashi, Sachio

    2009-01-01

    The purpose of this study was to evaluate the frequency of tracheobronchomalacia (TBM) associated with pulmonary emphysema with paired inspiratory-expiratory multidetector computed tomography (MDCT) using a low-dose technique. This study included 56 consecutive patients (55 men, 1 woman; mean age 68.9 years) with pulmonary emphysema who had undergone paired inspiratory-expiratory CT scanning with a low-dose technique (40 mA). All images were retrospectively examined by two thoracic radiologists in a blinded fashion. The diagnosis of TBM was based on the standard criterion of >50% reduction in the cross-sectional area of the tracheobronchial lumen at the end-expiratory phase. A mild TBM criterion of >30% reduction was also reviewed. All patients underwent pulmonary function tests. The relation between the forced expiratory volume in 1 s (FEV 1.0% ) and TBM was statistically analyzed. Four (7.1%) and eight (14.3%) patients were diagnosed as TBM based on the standard and mild criteria, respectively. In four patients, the percentages of luminal narrowing were 63.4% and 51.2%, respectively for tracheomalacia and 59.2% and 62.0%, respectively, for bronchomalacia. The FEV 1.0% values between patients with and without TBM showed no statistical difference. The incidence of TBM associated with pulmonary emphysema was 7.1% with the standard criterion. It is possible that TBM has been underdiagnosed in a number of patients with pulmonary emphysema. (author)

  4. Low Tidal Volume versus Non-Volume-Limited Strategies for Patients with Acute Respiratory Distress Syndrome. A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Walkey, Allan J; Goligher, Ewan C; Del Sorbo, Lorenzo; Hodgson, Carol L; Adhikari, Neill K J; Wunsch, Hannah; Meade, Maureen O; Uleryk, Elizabeth; Hess, Dean; Talmor, Daniel S; Thompson, B Taylor; Brower, Roy G; Fan, Eddy

    2017-10-01

    Trials investigating use of lower tidal volumes and inspiratory pressures for patients with acute respiratory distress syndrome (ARDS) have shown mixed results. To compare clinical outcomes of mechanical ventilation strategies that limit tidal volumes and inspiratory pressures (LTV) to strategies with tidal volumes of 10 to 15 ml/kg among patients with ARDS. This is a systematic review and meta-analysis of clinical trials investigating LTV mechanical ventilation strategies. We used random effects models to evaluate the effect of LTV on 28-day mortality, organ failure, ventilator-free days, barotrauma, oxygenation, and ventilation. Our primary analysis excluded trials for which the LTV strategy was combined with the additional strategy of higher positive end-expiratory pressure (PEEP), but these trials were included in a stratified sensitivity analysis. We performed metaregression of tidal volume gradient achieved between intervention and control groups on mortality effect estimates. We used Grading of Recommendations Assessment, Development, and Evaluation methodology to determine the quality of evidence. Seven randomized trials involving 1,481 patients met eligibility criteria for this review. Mortality was not significantly lower for patients receiving an LTV strategy (33.6%) as compared with control strategies (40.4%) (relative risk [RR], 0.87; 95% confidence interval [CI], 0.70-1.08; heterogeneity statistic I 2  = 46%), nor did an LTV strategy significantly decrease barotrauma or ventilator-free days when compared with a lower PEEP strategy. Quality of evidence for clinical outcomes was downgraded for imprecision. Metaregression showed a significant inverse association between larger tidal volume gradient between LTV and control groups and log odds ratios for mortality (β, -0.1587; P = 0.0022). Sensitivity analysis including trials that protocolized an LTV/high PEEP cointervention showed lower mortality associated with LTV (nine trials and 1

  5. Comparison of intermittent positive pressure breathing and temporary positive expiratory pressure in patients with severe chronic obstructive pulmonary disease.

    Science.gov (United States)

    Nicolini, Antonello; Mollar, Elena; Grecchi, Bruna; Landucci, Norma

    2014-01-01

    Results supporting the use and the effectiveness of positive expiratory, pressure devices in chronic obstructive pulmonary disease (COPD) patients are still controversial, We have tested the hypothesis that adding TPEP or IPPB to standard pharmacological therapy may provide additional clinical benefit over, pharmacological therapy only in patients with severe COPD. Fourty-five patients were randomized in three groups: a group was treated; with IPPB,a group was treated with TPEP and a group with pharmacological; therapy alone (control group). Primary outcome measures included the measurement of scale or, questionnaire concerning dyspnea (MRC scale),dyspnea,cough, and, sputum (BCSS) and quality of life (COPD assessment test) (CAT). Secondary, outcome measures were respiratory function testing,arterial blood gas,analysis,and hematological examinations. Both patients in the IPPB group and in the TPEP group showed a significant, improvement in two of three tests (MRC,CAT) compared to the control, group.However,in the group comparison analysis for, the same variables between IPPB group and TPEP group we observed a, significant improvement in the IPPB group (P≤.05 for MRC and P≤.01 for, CAT). The difference of action of the two techniques are evident in the results of, pulmonary function testing: IPPB increases FVC, FEV1, and MIP; this reflects, its capacity to increase lung volume. Also TPEP increases FVC and FEV1 (less, than IPPB), but increases MEP, while decreasing total lung capacity and, residual volume. The two techniques (IPPB and TPEP) improves significantly dyspnea; quality of; life tools and lung function in patients with severe COPD. IPPB demonstrated a greater effectiveness to improve dyspnea and quality of life tools (MRC, CAT) than TPEP. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  6. An expiratory assist during spontaneous breathing can compensate for endotracheal tube resistance.

    Science.gov (United States)

    Uchiyama, Akinori; Chang, Cheng; Suzuki, Shinya; Mashimo, Takashi; Fujino, Yuji

    2009-08-01

    Although inspiratory assist of spontaneous breathing in intubated patients is common, expiratory assist functions have rarely been reported. Effective expiratory support (ES) could be used to compensate for endotracheal tube (ETT) resistance during spontaneous breathing. In this study, we examined the performance of a new system designed to provide both inspiratory support (IS) and ES during spontaneous breathing with the goal of reducing the effective resistance of the ETT. The ES system consisted of a ventilator demand valve and a computer-controlled piston cylinder, which aspirated gas from the respiratory circuit during the expiratory phase. The movement of the piston was synchronized with spontaneous breathing. We compared the pressures at the tip of the ETT and in the breathing circuit during spontaneous breathing through an ETT of internal diameter (ID) 5 mm with that of an ETT with ID 8 mm in nine healthy adult male volunteers. The ventilatory mode was set to maintain a continuous airway pressure of 0 cm H(2)O. Three ventilator settings (no support, IS only, and IS plus ES) were compared using ID 5 mm ETT. We monitored pressure in the breathing circuit (P(aw)), ETT tip pressure (P(tip)), and respiratory flow. The P(tip) of the ID 5 mm ETT showed a large negative deflection during inspiration and a positive deflection during expiration without support. IS alone did not improve the respiratory pattern through the small ETT. However, IS plus ES resulted in negative P(aw) during expiration in addition to positive deflection of P(aw) during inspiration, making the pressure characteristics of P(tip) similar to those of ID 8 mm ETT. Moreover, IS plus ES produced a respiratory pattern through the ID 5 mm ETT that was similar to that through the ID 8 mm ETT. In this study of healthy volunteers, IS plus ES compensated for the airway resistance imposed by a ID 5.0 mm ETT to create pressure changes at the tip of the ETT similar to those of an ID 8.0 mm ETT.

  7. Peak expiratory flow as a predictor for the effectiveness of sport for patients with COPD.

    Science.gov (United States)

    Jungblut, S; Frickmann, H; Klingler, J; Zimmermann, B; Bargon, Joachim

    2006-01-31

    This study intended to find simple parameters that were able to determine the increase in physical performance as a result of sport in a group of patients with COPD (lung sport). We regularly investigated pulse, oxygenation and peak expiratory flow in participants with COPD of a "lung sport group", who participated in a structured weekly training program under professional supervision. Ten volunteers (7 females, 3 males, median of age = 69) with COPD (grade II-III) took part in the study. - The relative changes after 3 and 6 months were compared with the values of the first month of exercise. Measurements were carried out before exercise, after stamina training and at the end of the program. - Pulse and oxygenation did not show any changes. However, there was a significant improvement of peak flow after 6 months. - These peak flow changes represent further evidence of positive effects of sport in COPD and provide a parameter which allows the patients themselves to measure and evaluate the success of their physical activity.

  8. Impact of expiratory strength training in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Plowman, Emily K; Watts, Stephanie A; Tabor, Lauren; Robison, Raele; Gaziano, Joy; Domer, Amanda S; Richter, Joel; Vu, Tuan; Gooch, Clifton

    2016-06-01

    We evaluated the feasibility and impact of expiratory muscle strength training (EMST) on respiratory and bulbar function in persons with amyotrophic lateral sclerosis (ALS). Twenty-five ALS patients participated in this delayed intervention open-label clinical trial. Following a lead-in period, patients completed a 5-week EMST protocol. Outcome measures included: maximum expiratory pressure (MEP); physiologic measures of swallow and cough; and penetration-aspiration scale (PAS) scores. Of participants who entered the active phase of the study (n = 15), EMST was well tolerated and led to significant increases in MEPs and maximum hyoid displacement during swallowing post-EMST (P < 0.05). No significant differences were observed for PAS scores or cough spirometry measures. EMST was feasible and well tolerated in this small cohort of ALS patients and led to improvements in expiratory force-generating pressures and swallow kinematics. Further investigation is warranted to confirm these preliminary findings. Muscle Nerve 54: 48-53, 2016. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  9. Positive emotion communication: Fostering well-being at end of life.

    Science.gov (United States)

    Terrill, Alexandra L; Ellington, Lee; John, Kevin K; Latimer, Seth; Xu, Jiayun; Reblin, Maija; Clayton, Margaret F

    2018-04-01

    Little is known about positive emotion communication (PEC) in end-of-life care. This study aims to identify types and patterns of PEC among hospice nurses, caregivers, and patients. A coding system based on positive psychology theory was applied as a secondary analysis to audio recordings of hospice nurse home visits with cancer patients and family caregivers, collected as part of a prospective longitudinal study. Eighty recordings (4 visits from 20 triads) were coded for humor, connection, praise, positive focus, gratitude, taking joy/savoring, and perfunctory statements. Descriptive statistics revealed the greatest proportion of PEC was made by nurses. Humor was most frequently used across all speakers. Cluster analysis revealed four PEC visit types: Savor/Take Joy; Humor; Perfunctory; and Other-focused Expressions of Positive Emotions. Linear mixed effect regression was used to estimate the trajectory of PEC over time, but no significant change was found. We found that positive emotions are common in nurse, caregiver and patient communication at end-of-life and do not decline closer to death. This study is among the first to explore PEC at end-of-life, and offers a way to bring strengths-based approaches into end of life communication research. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Ventilation and gas exchange management after cardiac arrest.

    Science.gov (United States)

    Sutherasan, Yuda; Raimondo, Pasquale; Pelosi, Paolo

    2015-12-01

    For several decades, physicians had integrated several interventions aiming to improve the outcomes in post-cardiac arrest patients. However, the mortality rate after cardiac arrest is still as high as 50%. Post-cardiac arrest syndrome is associated with high morbidity and mortality due to not only poor neurological outcome and cardiovascular failure but also respiratory dysfunction. To minimize ventilator-associated lung injury, protective mechanical ventilation by using low tidal volume ventilation and driving pressure may decrease pulmonary complications and improve survival. Low level of positive end-expiratory pressure (PEEP) can be initiated and titrated with careful cardiac output and respiratory mechanics monitoring. Furthermore, optimizing gas exchange by avoiding hypoxia and hyperoxia as well as maintaining normocarbia may improve neurological and survival outcome. Early multidisciplinary cardiac rehabilitation intervention is recommended. Minimally invasive monitoring techniques, that is, echocardiography, transpulmonary thermodilution method measuring extravascular lung water, as well as transcranial Doppler ultrasound, might be useful to improve appropriate management of post-cardiac arrest patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. CDC releases ventilator-associated events criteria

    Directory of Open Access Journals (Sweden)

    Robbins RA

    2017-01-01

    Full Text Available No abstract available. Article truncated at 150 words. A new term has been coined by the CDC, ventilator-associated events (VAEs (1. In 2011, the CDC convened a working group composed of members of several stakeholder organizations to address the limitations of the definition of ventilator-associated pneumonia (VAP definition (2. The organizations represented in the Working Group include: the Critical Care Societies Collaborative (the American Association of Critical-Care Nurses, the American College of Chest Physicians, the American Thoracic Society, and the Society for Critical Care Medicine; the American Association for Respiratory Care; the Association of Professionals in Infection Control and Epidemiology; the Council of State and Territorial Epidemiologists; the Healthcare Infection Control Practices Advisory Committee’s Surveillance Working Group; the Infectious Diseases Society of America; and the Society for Healthcare Epidemiology of America. VAEs are defined by an increase oxygen (>0.2 in FiO2 or positive end-expiratory pressure (PEEP (≥3 cm H2O, after a previous stable baseline of at least 2 …

  12. Breath-by-breath analysis of expiratory gas concentration in chickens.

    Science.gov (United States)

    Itabisashi, T

    1981-01-01

    Expiratory oxygen and carbon-dioxide concentration were analysed breath by breath in order to examine their wave forms in adult awake hens restrained in various postural positions, including supine, prone and sitting positions. Expired gas was collected at the nostril in almost all the hens. In the sitting position free from vocalization, feeding, drinking, panting, and restlessness, hens showed various forms of stable pattern of oxygen-gas curves. These forms were classified into three types, or the ascending, flat and descending types, with respect to the plateau inclination. The waves of carbon-dioxide were not always a mirror image of those of oxygen. The rate of occurrence of each type varied with the hen's postural position. The wave form was altered with the experimental body-rotation of the hen. When placed between the deflections of stable pattern, the episodes of wave deformation resembling that seen at the time of uneven pulmonary ventilation in mammals could frequently be observed in any hen's posture examined. Cardiogenic oscillation appeared on the plateau of expired-gas curves.

  13. Open lung approach vs acute respiratory distress syndrome network ventilation in experimental acute lung injury.

    Science.gov (United States)

    Spieth, P M; Güldner, A; Carvalho, A R; Kasper, M; Pelosi, P; Uhlig, S; Koch, T; Gama de Abreu, M

    2011-09-01

    Setting and strategies of mechanical ventilation with positive end-expiratory pressure (PEEP) in acute lung injury (ALI) remains controversial. This study compares the effects between lung-protective mechanical ventilation according to the Acute Respiratory Distress Syndrome Network recommendations (ARDSnet) and the open lung approach (OLA) on pulmonary function and inflammatory response. Eighteen juvenile pigs were anaesthetized, mechanically ventilated, and instrumented. ALI was induced by surfactant washout. Animals were randomly assigned to mechanical ventilation according to the ARDSnet protocol or the OLA (n=9 per group). Gas exchange, haemodynamics, pulmonary blood flow (PBF) distribution, and respiratory mechanics were measured at intervals and the lungs were removed after 6 h of mechanical ventilation for further analysis. PEEP and mean airway pressure were higher in the OLA than in the ARDSnet group [15 cmH(2)O, range 14-18 cmH(2)O, compared with 12 cmH(2)O; 20.5 (sd 2.3) compared with 18 (1.4) cmH(2)O by the end of the experiment, respectively], and OLA was associated with improved oxygenation compared with the ARDSnet group after 6 h. OLA showed more alveolar overdistension, especially in gravitationally non-dependent regions, while the ARDSnet group was associated with more intra-alveolar haemorrhage. Inflammatory mediators and markers of lung parenchymal stress did not differ significantly between groups. The PBF shifted from ventral to dorsal during OLA compared with ARDSnet protocol [-0.02 (-0.09 to -0.01) compared with -0.08 (-0.12 to -0.06), dorsal-ventral gradients after 6 h, respectively]. According to the OLA, mechanical ventilation improved oxygenation and redistributed pulmonary perfusion when compared with the ARDSnet protocol, without differences in lung inflammatory response.

  14. Methylene Blue in Ventilator-Induced Lung Injury after Pneumonectomy: an Experimental Study

    Directory of Open Access Journals (Sweden)

    Ye. V Suborov

    2007-01-01

    Full Text Available Objective: to study the expediency and efficiency of using methylene blue (MB on a model of pneumectomy (PE and subsequent ventilator-induced lung injury (VILI in sheep. Materials and methods. The study was conducted at the Research Laboratory of University of Tromse. The experiment included 23 sheep weighing 41.0±4.9 kg. Thoracotomy and right-sided pneumonectomy were performed in the animals under general anesthesia and controlled artificial ventilation. After measurement of the parameters of systemic hemodynamics and extravascular water of the lung (EVWL, the animals were divided into 3 groups: 1 a control group (CG, n=7 with a tidal volume (TV of 6 ml/kg and an end-expiratory positive pressure (PEEP of 2 cm H2O; 2 a VILI group (n=9 with a TV of 12 ml/kg and a PEEP of 0 cm H2O; 3 a group of MB (n=7 that was given in parallel with a damaging ventilation mode. The thermodilution technique (using a Cold Z-021 monitor, (Pulsion, Germany was employed to measure volumetric parameters and EVWL. The parameters of pulmonary hemodynamics, respiratory mechanics, and blood gas composition were recorded. Results: After its reduction at PE, EVWL index increased during damaging ventilation in the VILI and MB groups. In addition, there was an increase in pulmonary artery wedge pressure after PE in the MB and VILI groups. In the latter group, arterial hypoxemia was observed at the end of the experiment. Along with this, after PE pulmonary compliance decreased and airway pressure elevated in the VILI and MB groups. Conclusion: In the presented model of VILI, MB does not prevent the development of postp-neumectomic edema of the lung. Key words: thermochromodilution, acute lung injury, pneumectomy, ventilator-induced lung injury, postpneumectomic edema of the lung, methylene blue.

  15. A high-flow nasal cannula system with relatively low flow effectively washes out CO2 from the anatomical dead space in a sophisticated respiratory model made by a 3D printer.

    Science.gov (United States)

    Onodera, Yu; Akimoto, Ryo; Suzuki, Hiroto; Okada, Masayuki; Nakane, Masaki; Kawamae, Kaneyuki

    2018-03-15

    Although clinical studies of the high-flow nasal cannula (HFNC) and its effect on positive end-expiratory pressure (PEEP) have been done, the washout effect has not been well evaluated. Therefore, we made an experimental respiratory model to evaluate the respiratory physiological effect of HFNC. An airway model was made by a 3D printer using the craniocervical 3D-CT data of a healthy 32-year-old male. CO 2 was infused into four respiratory lung models (normal-lung, open- and closed-mouth models; restrictive- and obstructive-lung, open-mouth models) to maintain the partial pressure of end-tidal CO 2 (P ET CO 2 ) at 40 mmHg. HFNC flow was changed from 10 to 60 L/min. Capnograms were recorded at the upper pharynx, oral cavity, subglottic, and inlet sites of each lung model. With the normal-lung, open-mouth model, 10 L/min of HFNC flow decreased the subglottic P ET CO 2 to 30 mmHg. Increasing the HFNC flow did not further decrease the subglottic P ET CO 2 . With the normal-lung, closed-mouth model, HFNC flow of 40 L/min was required to decrease the P ET CO 2 at all sites. Subglottic P ET CO 2 reached 30 mmHg with an HFNC flow of 60 L/min. In the obstructive-lung, open-mouth model, P ET CO 2 at all sites had the same trend as in the normal-lung, open-mouth model. In the restrictive-lung, open-mouth model, 20 L/min of HFNC flow decreased the subglottic P ET CO 2 to 25 mmHg, and it did not decrease further. As HFNC flow was increased, PEEP up to 7 cmH 2 O was gradually generated in the open-mouth models and up to 17 cmH 2 O in the normal-lung, closed-mouth model. The washout effect of the HFNC was effective with relatively low flow in the open-mouth models. The closed-mouth model needed more flow to generate a washout effect. Therefore, HFNC flow should be considered based on the need for the washout effect or PEEP.

  16. Effect of pilates method on inspiratory and expiratory muscle strength in the elderly

    Directory of Open Access Journals (Sweden)

    Beatriz Mendes Tozim

    2018-03-01

    Full Text Available With aging, the respiratory muscle strength decreases and the pilates method is a technique that uses respiration as one of its principles. The present study has the aim of analyzing the influence of the pilates method on respiratory muscle strength in older women. For the evaluation of respiratory muscle strength (inspiratory and expiratory, manovacuometer was used. Thirty-one older women were divided into two groups: 14 participated in the pilates group and 17 in the control group. Participants of the pilates group performed 16 sessions of pilates method with an hour of training, twice week for eight weeks. The control group participated in four educational lectures for eight weeks. For statistical analysis, Shapiro-Wilk, ANOVA for repeated measures (p <0.05 and Cohen’s D index were performed. The results showed significant difference and the mean effect for the Cohen’s D index expiratory muscle strength of the pilates group when comparing before (69.71 ± 25.48 and after (85.23 ± 22.21 training (p<0.05 with an increase of 23%. The results of inspiratory muscle strength were not significant but presented an average effect for the Cohen’s D index for the pilates group before (69.71 ± 35.46 and after (88.00 ± 34.87 training, with an increase of 27%. The control group did not present significant differences for the variables evaluated. It could be concluded that the pilates method is effective in improving expiratory muscle strength and provides positive effects on the increase in inspiratory muscle strength.

  17. Evaluation of a computerized system for mechanical ventilation of infants.

    Science.gov (United States)

    Tehrani, Fleur T; Abbasi, Soraya

    2009-04-01

    To evaluate a computerized system for mechanical ventilation of infants. FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fraction of inspired oxygen (F(IO2)), minute ventilation, and control of weaning. It is used as an open-loop decision support system or as a closed-loop technique. Blood gas and ventilation data were collected from 12 infants in the neonatal intensive care at baseline and at the next round of evaluation. This data were input to open-loop version of FLEX. The system recommendations were compared to clinical determinations. FLEX recommended values for ventilation were on the average within 25% and 16.5% of the measured values at baseline and at the next round of evaluation, respectively. For F(IO2) and PEEP, FLEX recommended values were in general agreement with the clinical settings. FLEX recommendations for weaning were the same as the clinical determinations 50% of the time at baseline and 55% of the time at the next round of evaluation. FLEX did not recommend weaning for infants with weak spontaneous breathing effort or those who showed signs of dyspnea. A computerized system for mechanical ventilation is evaluated for treatment of infants. The results of the study show that the system has good potential for use in neonatal ventilatory care. Further refinements can be made in the system for very low-birth-weight infants.

  18. Intraoperative protective mechanical ventilation and risk of postoperative respiratory complications: hospital based registry study.

    Science.gov (United States)

    Ladha, Karim; Vidal Melo, Marcos F; McLean, Duncan J; Wanderer, Jonathan P; Grabitz, Stephanie D; Kurth, Tobias; Eikermann, Matthias

    2015-07-14

    To evaluate the effects of intraoperative protective ventilation on major postoperative respiratory complications and to define safe intraoperative mechanical ventilator settings that do not translate into an increased risk of postoperative respiratory complications. Hospital based registry study. Academic tertiary care hospital and two affiliated community hospitals in Massachusetts, United States. 69,265 consecutively enrolled patients over the age of 18 who underwent a non-cardiac surgical procedure between January 2007 and August 2014 and required general anesthesia with endotracheal intubation. Protective ventilation, defined as a median positive end expiratory pressure (PEEP) of 5 cmH2O or more, a median tidal volume of less than 10 mL/kg of predicted body weight, and a median plateau pressure of less than 30 cmH2O. Composite outcome of major respiratory complications, including pulmonary edema, respiratory failure, pneumonia, and re-intubation. Of the 69,265 enrolled patients 34,800 (50.2%) received protective ventilation and 34,465 (49.8%) received non-protective ventilation intraoperatively. Protective ventilation was associated with a decreased risk of postoperative respiratory complications in multivariable regression (adjusted odds ratio 0.90, 95% confidence interval 0.82 to 0.98, P=0.013). The results were similar in the propensity score matched cohort (odds ratio 0.89, 95% confidence interval 0.83 to 0.97, P=0.004). A PEEP of 5 cmH2O and median plateau pressures of 16 cmH2O or less were associated with the lowest risk of postoperative respiratory complications. Intraoperative protective ventilation was associated with a decreased risk of postoperative respiratory complications. A PEEP of 5 cmH2O and a plateau pressure of 16 cmH2O or less were identified as protective mechanical ventilator settings. These findings suggest that protective thresholds differ for intraoperative ventilation in patients with normal lungs compared with those used for patients

  19. Evaluating the effects of protective ventilation on organ-specific cytokine production in porcine experimental postoperative sepsis.

    Science.gov (United States)

    Sperber, Jesper; Lipcsey, Miklós; Larsson, Anders; Larsson, Anders; Sjölin, Jan; Castegren, Markus

    2015-05-10

    Protective ventilation with lower tidal volume (VT) and higher positive end-expiratory pressure (PEEP) reduces the negative additive effects of mechanical ventilation during systemic inflammatory response syndrome. We hypothesised that protective ventilation during surgery would affect the organ-specific immune response in an experimental animal model of endotoxin-induced sepsis-like syndrome. 30 pigs were laparotomised for 2 hours (h), after which a continuous endotoxin infusion was started at 0.25 micrograms × kg(-1) × h(-1) for 5 h. Catheters were placed in the carotid artery, hepatic vein, portal vein and jugular bulb. Animals were randomised to two protective ventilation groups (n = 10 each): one group was ventilated with VT 6 mL × kg(-1) during the whole experiment while the other group was ventilated during the surgical phase with VT of 10 mL × kg(-1). In both groups PEEP was 5 cmH2O during surgery and increased to 10 cmH2O at the start of endotoxin infusion. A control group (n = 10) was ventilated with VT of 10 mL × kg(-1) and PEEP 5 cm H20 throughout the experiment. In four sample locations we a) simultaneously compared cytokine levels, b) studied the effect of protective ventilation initiated before and during endotoxemia and c) evaluated protective ventilation on organ-specific cytokine levels. TNF-alpha levels were highest in the hepatic vein, IL-6 levels highest in the artery and jugular bulb and IL-10 levels lowest in the artery. Protective ventilation initiated before and during endotoxemia did not differ in organ-specific cytokine levels. Protective ventilation led to lower levels of TNF-alpha in the hepatic vein compared with the control group, whereas no significant differences were seen in the artery, portal vein or jugular bulb. Variation between organs in cytokine output was observed during experimental sepsis. We see no implication from cytokine levels for initiating protective ventilation before endotoxemia. However, during endotoxemia

  20. Increasing the inspiratory time and I:E ratio during mechanical ventilation aggravates ventilator-induced lung injury in mice.

    Science.gov (United States)

    Müller-Redetzky, Holger C; Felten, Matthias; Hellwig, Katharina; Wienhold, Sandra-Maria; Naujoks, Jan; Opitz, Bastian; Kershaw, Olivia; Gruber, Achim D; Suttorp, Norbert; Witzenrath, Martin

    2015-01-28

    Lung-protective ventilation reduced acute respiratory distress syndrome (ARDS) mortality. To minimize ventilator-induced lung injury (VILI), tidal volume is limited, high plateau pressures are avoided, and positive end-expiratory pressure (PEEP) is applied. However, the impact of specific ventilatory patterns on VILI is not well defined. Increasing inspiratory time and thereby the inspiratory/expiratory ratio (I:E ratio) may improve oxygenation, but may also be harmful as the absolute stress and strain over time increase. We thus hypothesized that increasing inspiratory time and I:E ratio aggravates VILI. VILI was induced in mice by high tidal-volume ventilation (HVT 34 ml/kg). Low tidal-volume ventilation (LVT 9 ml/kg) was used in control groups. PEEP was set to 2 cm H2O, FiO2 was 0.5 in all groups. HVT and LVT mice were ventilated with either I:E of 1:2 (LVT 1:2, HVT 1:2) or 1:1 (LVT 1:1, HVT 1:1) for 4 hours or until an alternative end point, defined as mean arterial blood pressure below 40 mm Hg. Dynamic hyperinflation due to the increased I:E ratio was excluded in a separate group of animals. Survival, lung compliance, oxygenation, pulmonary permeability, markers of pulmonary and systemic inflammation (leukocyte differentiation in lung and blood, analyses of pulmonary interleukin-6, interleukin-1β, keratinocyte-derived chemokine, monocyte chemoattractant protein-1), and histopathologic pulmonary changes were analyzed. LVT 1:2 or LVT 1:1 did not result in VILI, and all individuals survived the ventilation period. HVT 1:2 decreased lung compliance, increased pulmonary neutrophils and cytokine expression, and evoked marked histologic signs of lung injury. All animals survived. HVT 1:1 caused further significant worsening of oxygenation, compliance and increased pulmonary proinflammatory cytokine expression, and pulmonary and blood neutrophils. In the HVT 1:1 group, significant mortality during mechanical ventilation was observed. According to the "baby lung

  1. Validity of peak expiratory flow measurement in assessing reversibility of airflow obstruction.

    Science.gov (United States)

    Dekker, F W; Schrier, A C; Sterk, P J; Dijkman, J H

    1992-01-01

    BACKGROUND: Assessing the reversibility of airflow obstruction by peak expiratory (PEF) measurements would be practicable in general practice, but its usefulness has not been investigated. METHODS: PEF measurements were performed (miniWright peak flow meter) in 73 general practice patients (aged 40 to 84) with a history of asthma or chronic obstructive lung disease before and after 400 micrograms inhaled sulbutamol. The change in PEF was compared with the change in forced expiratory volume in one second (FEV1). Reversible airflow obstruction was analysed in two ways according to previous criteria. When defined as a 9% or greater increase in FEV1 expressed as a percentage of predicted values reversibility was observed in 42% of patients. Relative operating characteristic analysis showed that an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (the sensitivity and specificity of an increase of 60 l/min in detecting a 9% or more increase in FEV1 as a percentage of predicted values were 68% and 93% respectively, with a positive predictive value of 87%). When defined as an increase of 190 ml or more in FEV1, reversible airflow obstruction was observed in 53% of patients. Again an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (sensitivity 56%, specificity 94%, and positive predictive value 92%). CONCLUSION: Absolute changes in PEF can be used as a simple technique to diagnose reversible airflow obstruction in patients from general practice. PMID:1519192

  2. Deep breathing exercises with positive expiratory pressure at a higher rate improve oxygenation in the early period after cardiac surgery--a randomised controlled trial.

    Science.gov (United States)

    Urell, Charlotte; Emtner, Margareta; Hedenström, Hans; Tenling, Arne; Breidenskog, Marie; Westerdahl, Elisabeth

    2011-07-01

    In addition to early mobilisation, a variety of breathing exercises are used to prevent postoperative pulmonary complications after cardiac surgery. The optimal duration of the treatment is not well evaluated. The aim of this study was to determine the effect of 30 versus 10 deep breaths hourly, while awake, with positive expiratory pressure on oxygenation and pulmonary function the first days after cardiac surgery. A total of 181 patients, undergoing cardiac surgery, were randomised into a treatment group, performing 30 deep breaths hourly the first postoperative days, or into a control group performing 10 deep breaths hourly. The main outcome measurement arterial blood gases and the secondary outcome pulmonary function, evaluated with spirometry, were determined on the second postoperative day. Preoperatively, both study groups were similar in terms of age, SpO(2), forced expiratory volume in 1s and New York Heart Association classification. On the second postoperative day, arterial oxygen tension (PaO(2)) was 8.9 ± 1.7 kPa in the treatment group and 8.1 ± 1.4 kPa in the control group (p = 0.004). Arterial oxygen saturation (SaO(2)) was 92.7 ± 3.7% in the treatment group and 91.1 ± 3.8% in the control group (p = 0.016). There were no differences in measured lung function between the groups or in compliance to the breathing exercises. Compliance was 65% of possible breathing sessions. A significantly increased oxygenation was found in patients performing 30 deep breaths the first two postoperative days compared with control patients performing 10 deep breaths hourly. These results support the implementation of a higher rate of deep breathing exercises in the initial phase after cardiac surgery. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  3. Exact positioning of the robotic arm end effector

    Science.gov (United States)

    Korepanov, Valery; Dudkin, Fedir

    2016-07-01

    Orbital service becomes a new challenge of space exploration. The necessity to introduce it is connected first of all with an attractive opportunity to prolong the exploitation terms of expensive commercial satellites by, e.g., refilling of fuel or changing batteries. Other application area is a fight with permanently increasing amount of space litter - defunct satellites, burnt-out rocket stages, discarded trash and other debris. Now more than few tens of thousands orbiting objects larger than 5-10 cm (or about 1 million junks larger than 1 cm) are a huge problem for crucial and costly satellites and manned vehicles. For example, in 2014 the International Space Station had to change three times its orbit to avoid collision with space debris. So the development of the concepts and actions related to removal of space debris or non-operational satellites with use of robotic arm of a servicing satellite is very actual. Such a technology is also applicable for unmanned exploratory missions in solar system, for example for collecting a variety of samples from a celestial body surface. Naturally, the robotic arm movements should be controlled with great accuracy at influence of its non-rigidity, thermal and other factors. In these circumstances often the position of the arm end effector has to be controlled with high accuracy. The possibility of coordinate determination for the robotic arm end effector with use of a low frequency active electromagnetic system has been considered in the presented report. The proposed design of such a system consists of a small magnetic dipole source, which is mounted inside of the arm end effector and two or three 3-component magnetic field sensors mounted on a servicing satellite body. The data from this set of 3-component magnetic field sensors, which are fixed relatively to the satellite body, allows use of the mathematical approach for determination of position and orientation of the magnetic dipole source. The theoretical

  4. Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery.

    Science.gov (United States)

    Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi

    2013-06-01

    Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function.

  5. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway.

    Directory of Open Access Journals (Sweden)

    Samantha Torres Grams

    Full Text Available Maximal Inspiratory Pressure (MIP is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway.This study aimed to compare the MIP values assessed by standard method (MIPsta and by unidirectional expiratory valve method (MIPuni in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated.This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B at two moments (Tests 1 and 2 to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1] was used to determine intraobserver and interobserver reproducibility.The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O than the mean values for MIPsta (-102.5 ± 23.9 cmH2O (p<0.001. Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91, and high correlation for Test 2 (ICC[2,1] = 0.88. The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86 and evaluator B (ICC[2,1] = 0.77.MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.

  6. The respiratory drive to thoracic motoneurones in the cat and its relation to the connections from expiratory bulbospinal neurones

    Science.gov (United States)

    Saywell, S A; Anissimova, N P; Ford, T W; Meehan, C F; Kirkwood, P A

    2007-01-01

    The descending control of respiratory-related motoneurones in the thoracic spinal cord remains the subject of some debate. In this study, direct connections from expiratory bulbospinal neurones to identified motoneurones were investigated using spike-triggered averaging and the strengths of connection revealed were related to the presence and size of central respiratory drive potentials in the same motoneurones. Intracellular recordings were made from motoneurones in segments T5–T9 of the spinal cord of anaesthetized cats. Spike-triggered averaging from expiratory bulbospinal neurones in the caudal medulla revealed monosynaptic EPSPs in all groups of motoneurones, with the strongest connections to expiratory motoneurones with axons in the internal intercostal nerve. In the latter, connection strength was similar irrespective of the target muscle (e.g. external abdominal oblique or internal intercostal) and the EPSP amplitude was positively correlated with the amplitude of the central respiratory drive potential of the motoneurone. For this group, EPSPs were found in 45/83 bulbospinal neurone/motoneurone pairs, with a mean amplitude of 40.5 μV. The overall strength of the connection supports previous measurements made by cross-correlation, but is about 10 times stronger than that reported in the only previous similar survey to use spike-triggered averaging. Calculations are presented to suggest that this input alone is sufficient to account for all the expiratory depolarization seen in the recorded motoneurones. However, extra sources of input, or amplification of this one, are likely to be necessary to produce a useful motoneurone output. PMID:17204500

  7. High-Frequency Chest Compression: A Summary of the Literature

    Directory of Open Access Journals (Sweden)

    Cara F Dosman

    2005-01-01

    Full Text Available The purpose of the present literature summary is to describe high-frequency chest compression (HFCC, summarize its history and outline study results on its effect on mucolysis, mucus transport, pulmonary function and quality of life. HFCC is a mechanical method of self-administered chest physiotherapy, which induces rapid air movement in and out of the lungs. This mean oscillated volume is an effective method of mucolysis and mucus clearance. HFCC can increase independence. Some studies have shown that HFCC leads to more mucus clearance and better lung function compared with conventional chest physiotherapy. However, HFCC also decreases end-expiratory lung volume, which can lead to increased airway resistance and a decreased oscillated volume. Adding positive end-expiratory pressure to HFCC has been shown to prevent this decrease in end-expiratory lung volume and to increase the oscillated volume. It is possible that the HFCC-induced decrease in end-expiratory lung volume may result in more mucus clearance in airways that remain open by reducing airway size. Adjunctive methods, such as positive end-expiratory pressure, may not always be needed to make HFCC more effective.

  8. Diagnostic methods to assess inspiratory and expiratory muscle strength

    Directory of Open Access Journals (Sweden)

    Pedro Caruso

    2015-04-01

    Full Text Available Impairment of (inspiratory and expiratory respiratory muscles is a common clinical finding, not only in patients with neuromuscular disease but also in patients with primary disease of the lung parenchyma or airways. Although such impairment is common, its recognition is usually delayed because its signs and symptoms are nonspecific and late. This delayed recognition, or even the lack thereof, occurs because the diagnostic tests used in the assessment of respiratory muscle strength are not widely known and available. There are various methods of assessing respiratory muscle strength during the inspiratory and expiratory phases. These methods are divided into two categories: volitional tests (which require patient understanding and cooperation; and non-volitional tests. Volitional tests, such as those that measure maximal inspiratory and expiratory pressures, are the most commonly used because they are readily available. Non-volitional tests depend on magnetic stimulation of the phrenic nerve accompanied by the measurement of inspiratory mouth pressure, inspiratory esophageal pressure, or inspiratory transdiaphragmatic pressure. Another method that has come to be widely used is ultrasound imaging of the diaphragm. We believe that pulmonologists involved in the care of patients with respiratory diseases should be familiar with the tests used in order to assess respiratory muscle function.Therefore, the aim of the present article is to describe the advantages, disadvantages, procedures, and clinical applicability of the main tests used in the assessment of respiratory muscle strength.

  9. Changes in forced expiratory volume in 1 second over time in COPD

    DEFF Research Database (Denmark)

    Vestbo, Jørgen; Edwards, Lisa D; Scanlon, Paul D

    2011-01-01

    A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce.......A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce....

  10. Mechanical ventilators in the hot zone: effects of a CBRN filter on patient protection and battery life.

    Science.gov (United States)

    Blakeman, Thomas C; Toth, Peter; Rodriquez, Dario; Branson, Richard D

    2010-09-01

    In a contaminated environment, respiratory protection for ventilator dependent patients can be achieved by attaching a chemical, biological, radiological, or nuclear (CBRN) filter to the air intake port of a portable ventilator. We evaluated the effect of the filter on battery performance of four portable ventilators in a laboratory setting. Each ventilator was attached to a test lung. Ventilator settings were: assist control (AC) mode, respiratory rate 35 bpm, tidal volume 450 ml, positive end-expiratory pressure (PEEP) 10 cm H(2)O, inspiratory time 0.8 s, and FIO(2) 0.21. Ventilators were operated until the battery was fully discharged. We also evaluated the ventilators' ability to deliver all the gas through the CBRN filter and analyzed the pressures required to breathe through the anti-asphyxiation valve of a failed device. The range of battery life varied widely across different ventilator models (99.8-562.6 min). There was no significant difference in battery life (pventilator dependent patients when environmental contamination is present, although conditions exist where all gas does not pass through the filter with some ventilators under normal operating conditions. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  11. Assessment and monitoring of flow limitation and other parameters from flow/volume loops.

    Science.gov (United States)

    Dueck, R

    2000-01-01

    Flow/volume (F/V) spirometry is routinely used for assessing the type and severity of lung disease. Forced vital capacity (FVC) and timed vital capacity (FEV1) provide the best estimates of airflow obstruction in patients with asthma, chronic obstructive pulmonary disease (COPD) and emphysema. Computerized spirometers are now available for early home recognition of asthma exacerbation in high risk patients with severe persistent disease, and for recognition of either infection or rejection in lung transplant patients. Patients with severe COPD may exhibit expiratory flow limitation (EFL) on tidal volume (VT) expiratory F/V (VTF/V) curves, either with or without applying negative expiratory pressure (NEP). EFL results in dynamic hyperinflation and persistently raised alveolar pressure or intrinsic PEEP (PEEPi). Hyperinflation and raised PEEPi greatly enhance dyspnea with exertion through the added work of the threshold load needed to overcome raised pleural pressure. Esophageal (pleural) pressure monitoring may be added to VTF/V loops for assessing the severity of PEEPi: 1) to optimize assisted ventilation by mask or via endotracheal tube with high inspiratory flow rates to lower I:E ratio, and 2) to assess the efficacy of either pressure support ventilation (PSV) or low level extrinsic PEEP in reducing the threshold load of PEEPi. Intraoperative tidal volume F/V loops can also be used to document the efficacy of emphysema lung volume reduction surgery (LVRS) via disappearance of EFL. Finally, the mechanism of ventilatory constraint can be identified with the use of exercise tidal volume F/V loops referenced to maximum F/V loops and static lung volumes. Patients with severe COPD show inspiratory F/V loops approaching 95% of total lung capacity, and flow limitation over the entire expiratory F/V curve during light levels of exercise. Surprisingly, patients with a history of congestive heart failure may lower lung volume towards residual volume during exercise

  12. The respiratory drive to thoracic motoneurones in the cat and its relation to the connections from expiratory bulbospinal neurones

    DEFF Research Database (Denmark)

    Saywell, S A; Anissimova, N P; Ford, T W

    2007-01-01

    of connection revealed were related to the presence and size of central respiratory drive potentials in the same motoneurones. Intracellular recordings were made from motoneurones in segments T5-T9 of the spinal cord of anaesthetized cats. Spike-triggered averaging from expiratory bulbospinal neurones...... in the caudal medulla revealed monosynaptic EPSPs in all groups of motoneurones, with the strongest connections to expiratory motoneurones with axons in the internal intercostal nerve. In the latter, connection strength was similar irrespective of the target muscle (e.g. external abdominal oblique or internal...... intercostal) and the EPSP amplitude was positively correlated with the amplitude of the central respiratory drive potential of the motoneurone. For this group, EPSPs were found in 45/83 bulbospinal neurone/motoneurone pairs, with a mean amplitude of 40.5 microV. The overall strength of the connection supports...

  13. Report on the heat stroke position at the end of 1964

    CSIR Research Space (South Africa)

    Wyndham, CH

    1965-01-01

    Full Text Available The aim of this study for the Transvaal and Orange Free State Chamber of Mines Research Organization was to examine the heat stroke position at the end of 1964 in terms of the trends in the numbers of stopes and development ends and also...

  14. Positioning of electrode plane systematically influences EIT imaging.

    Science.gov (United States)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Müller-Lisse, Ullrich; Möller, Knut; Zhao, Zhanqi

    2015-06-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔIERV/ERV, ΔIVT/VT and ΔIIRV/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔIERV/ERV ratio in all subjects was significantly higher than the normalized ΔIIRV/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions.

  15. Effects of positive expiratory pressure on pulmonary clearance of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid in healthy individuals

    Directory of Open Access Journals (Sweden)

    Isabella Martins de Albuquerque

    Full Text Available ABSTRACT Objective: To evaluate the effects of positive expiratory pressure (PEP on pulmonary epithelial membrane permeability in healthy subjects. Methods: We evaluated a cohort of 30 healthy subjects (15 males and 15 females with a mean age of 28.3 ± 5.4 years, a mean FEV1/FVC ratio of 0.89 ± 0.14, and a mean FEV1 of 98.5 ± 13.1% of predicted. Subjects underwent technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA radioaerosol inhalation lung scintigraphy in two stages: during spontaneous breathing; and while breathing through a PEP mask at one of three PEP levels-10 cmH2O (n = 10, 15 cmH2O (n = 10, and 20 cmH2O (n = 10. The 99mTc-DTPA was nebulized for 3 min, and its clearance was recorded by scintigraphy over a 30-min period during spontaneous breathing and over a 30-min period during breathing through a PEP mask. Results: The pulmonary clearance of 99mTc-DTPA was significantly shorter when PEP was applied-at 10 cmH2O (p = 0.044, 15 cmH2O (p = 0.044, and 20 cmH2O (p = 0.004-in comparison with that observed during spontaneous breathing. Conclusions: Our findings indicate that PEP, at the levels tested, is able to induce an increase in pulmonary epithelial membrane permeability and lung volume in healthy subjects.

  16. Cystic lung disease: a comparison of cystic size, as seen on expiratory and inspiratory HRCT scans

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Nam, Kyung Jin; Choi, Seok Jin; Goo, Jin Mo

    2000-01-01

    To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary

  17. Cystic lung disease: a comparison of cystic size, as seen on expiratory and inspiratory HRCT scans

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki Nam; Yoon, Seong Kuk; Nam, Kyung Jin [Donga University College of Medicine, Pusan (Korea, Republic of); Choi, Seok Jin [Inje University College of Medicine, Gimhae (Korea, Republic of); Goo, Jin Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2000-06-01

    To determine the effects of respiration on the size of lung cysts by comparing inspiratory and expiratory high-resolution CT (HRCT) scans. The authors evaluated the size of cystic lesions, as seen on paired inspiratory and expiratory HRCT scans, in 54 patients with Langerhans cell histiocytosis (n = 3), pulmonary lymphangiomyomatosis (n = 4), confluent centrilobular emphysema (n = 9), paraseptal emphysema and bullae (n = 16), cystic bronchiectasis (n = 13), and honeycombing (n = 9). Using paired inspiratory and expiratory HRCT scans obtained at the corresponding anatomic level, a total of 270 cystic lesions were selected simultaneously on the basis of five lesions per lung disease. Changes in lung cyst size observed during respiration were assessed by two radiologists. In a limited number of cases (n = 11), pathologic specimens were obtained by open lung biopsy or lobectomy. All cystic lesions in patients with Langerhans cell histiocytosis, lymphangiomyomatosis, cystic bronchiectasis, honeycombing, and confluent centrilobular emphysema became smaller on expiration, but in two cases of paraseptal emphysema and bullae there was no change. In cases in which expiratory CT scans indicate that cysts have become smaller, cystic lesions may communicate with the airways. To determine whether, for cysts and cystic lesions, this connection does in fact exist, paired inspiratory and expiratory HRCT scans are necessary.

  18. High resolution CT in cystic fibrosis--the contribution of expiratory scans

    International Nuclear Information System (INIS)

    Dorloechter, Ludger; Nes, Harald; Fluge, Gjermund; Rosendahl, Karen

    2003-01-01

    Introduction: The use of high-resolution computed tomography (HRCT) is well accepted as an accurate method for evaluation of lung parenchyma in cystic fibrosis (CF). Several scoring methods exist and, in common, all are based on HRCT findings during inspiration alone. Objective: To examine whether expiratory HRCT scans could add information about the degree of mosaic perfusion in patients with CF. Methods and patients: Pulmonary HRCT was performed in 17 CF patients (median age of 12 years) with 1-mm thin sections and 10-mm intervals during inspiration, followed by 1-mm thin sections with 20-mm intervals during expiration. HRCT was scored by using a modified Bhalla method. Results: The mean HRCT score was 8.2. Out of 17 patients, 11 (65%) demonstrated a pathological mosaic perfusion in expiration, while only three patients showed mosaic perfusion in inspiration. The degree of expiratory mosaic perfusion was graded as severe in nine patients and moderate in two patients. There was a significant correlation between our modified HRCT score and lung function, as measured by forced expiratory volume in 1 s (FEV1% predicted, P<0.01). Conclusion: Mosaic perfusion in expiration was a common pathological HRCT finding in our study group. The clinical significance of this finding needs further evaluation

  19. Mida arvate ideest, et kõrgkoole võiks juhtida ülikoolivälistest inimestest koosnev nõukogu? / Jaak Aaviksoo, Maris Mälzer, Peeter Kreitzberg, Peep Sürje

    Index Scriptorium Estoniae

    2010-01-01

    Küsimusele vastavad Tartu Ülikooli eelmine rektor Jaak Aaviksoo, Eesti Üliõpilaskondade Liidu esimees Maris Mälzer, Riigikogu kultuurikomisjoni esimees Peeter Kreitzberg ja Tallinna Tehnikaülikooli rektor Peep Sürje

  20. Regional specific mean expiratory gas flow from Slmsub(Kr) equilibrium inhalation data

    International Nuclear Information System (INIS)

    Hamilton, D.; Causer, D.A.; McIntosh, J.A.; Godfrey, K.R.

    1985-01-01

    A new method of analysing the data available from routine sup(81m) Kr equilibrium inhalation investigations has been developed. The data for analysis are acquired from a gamma camera in the form of a sequential series of images from which multiple breath activity-time curves are generated for eight regions in the lung. The method is based on a description of the behaviour of the radioactive gas in the lung using a mathematical model. Values of specific mean expiratory gas flow, that is mean expiratory gas flow per unit lung volume, are calculated from the application of the model to the expiratory phase only only of a single breath activity-time curve which is generated from the multiple breath activity-time curve using post-acquisition gating. This method overcomes the problem of non-uniform inspiratory concentration of tracer gas experienced in previously reported techniques of analysing inhalation data obtained using poorly soluble radioactive gases. The model is shown, in simulation studies, to be an adequate description of the behaviour of radioactive gas in the lung and the analysis technique is shown, in clinical studies, to be both reproducible and sensitive to disease state. (orig.)

  1. End-threaded intramedullary positive profile screw ended self-tapping pin (Admit pin) - A cost-effective novel implant for fixing canine long bone fractures.

    Science.gov (United States)

    Chanana, Mitin; Kumar, Adarsh; Tyagi, Som Prakash; Singla, Amit Kumar; Sharma, Arvind; Farooq, Uiase Bin

    2018-02-01

    The current study was undertaken to evaluate the clinical efficacy of end-threaded intramedullary pinning for management of various long bone fractures in canines. This study was conducted in two phases, managing 25 client-owned dogs presented with different fractures. The technique of application of end-threaded intramedullary pinning in long bone fractures was initially standardized in 6 clinical patients presented with long bone fractures. In this phase, end-threaded pins of different profiles, i.e., positive and negative, were used as the internal fixation technique. On the basis of results obtained from standardization phase, 19 client-owned dogs clinically presented with different fractures were implanted with end-threaded intramedullary positive profile screw ended self-tapping pin in the clinical application phase. The patients, allocated randomly in two groups, when evaluated postoperatively revealed slight pin migration in Group-I (negative profile), which resulted in disruption of callus site causing delayed union in one case and large callus formation in other two cases whereas no pin migration was observed in Group-II (positive profile). Other observations in Group-I was reduced muscle girth and delayed healing time as compared to Group-II. In clinical application, phase 21 st and 42 nd day post-operative radiographic follow-up revealed no pin migration in any of the cases, and there was no bone shortening or fragment collapse in end-threaded intramedullary positive profile screw ended self-tapping pin. The end-threaded intramedullary positive profile screw ended self-tapping pin used for fixation of long bone fractures in canines can resist pin migration, pin breakage, and all loads acting on the bone, i.e., compression, tension, bending, rotation, and shearing to an extent with no post-operative complications.

  2. Abdominal wall reconstruction for large incisional hernia restores expiratory lung function

    DEFF Research Database (Denmark)

    Jensen, Kristian K; Backer, Vibeke; Jorgensen, Lars N

    2017-01-01

    BACKGROUND: Respiratory complications secondary to intermittent intra-abdominal hypertension and/or atelectasis are common after abdominal wall reconstruction for large incisional hernias. It is unknown if the respiratory function of this patient group is affected long term or impairs activities...... of daily living. We hypothesized that abdominal wall reconstruction for large incisional hernia would not lead to improved, long-term pulmonary function or respiratory quality of life. METHODS: Eighteen patients undergoing open abdominal wall reconstruction with mesh for a large incisional hernia...... (horizontal fascial defect width >10 cm) were compared with 18 patients with an intact abdominal wall who underwent colorectal resection. Patients were examined pre- and 1-year postoperatively. Examined measures included forced vital capacity, forced expiratory volume in first second, peak expiratory flow...

  3. Kas omakeelsel haridusel ja teadusel on tulevikku? / Kirsti Siitonen, Jolanta Zabarskaite, Josep Soler-Carbonell, Rainer Enrique Hamel ; intervjueerinud Peep Nemvalts ; tõlkinud Doris Kareva, Aili Künstler

    Index Scriptorium Estoniae

    2011-01-01

    TLÜ teaduskeelekeskus korraldas koos TLÜ eesti keele ja kultuuri instituudiga 29. ja 30. augustil rahvusvahelise konverentsi "Rahvuskeeled teaduses ja kõrghariduses". Sel teemal vastavad TLÜ teaduskeelekeskuse juhataja Peep Nemvaltsi küsimustele konverentsi rahvusvahelised esinejad

  4. Factors influencing peak expiratory flow in teenage boys | van ...

    African Journals Online (AJOL)

    Background. Peak expiratory flow (PEF) is a useful measure of pulmonary health status and is frequently utilised in asthm, management. Reduction in PEF is usually indicative of onset (of asthma symptoms. However, use can be made of PEF values only if normal values are known. The definition of normal range is always ...

  5. Positioning of electrode plane systematically influences EIT imaging

    International Nuclear Information System (INIS)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Kretschmer, Jörn; Möller, Knut; Zhao, Zhanqi; Müller-Lisse, Ullrich

    2015-01-01

    Up to now, the impact of electrode positioning on electrical impedance tomography (EIT) had not been systematically analyzed due to the lack of a reference method. The aim of the study was to determine the impact of electrode positioning on EIT imaging in spontaneously breathing subjects at different ventilation levels with our novel lung function measurement setup combining EIT and body plethysmography. EIT measurements were conducted in three transverse planes between the 3rd and 4th intercostal space (ICS), at the 5th ICS and between the 6th and 7th ICS (named as cranial, middle and caudal) on 12 healthy subjects. Pulmonary function tests were performed simultaneously by body plethysmography to determine functional residual capacity (FRC), vital capacity (VC), tidal volume (VT), expiratory reserve volume (ERV), and inspiratory reserve volume (IRV). Ratios of impedance changes and body plethysmographic volumes were calculated for every thorax plane (ΔI_E_R_V/ERV, ΔI_V_T/VT and ΔI_I_R_V/IRV). In all measurements of a subject, FRC values and VC values differed ≤5%, which confirmed that subjects were breathing at comparable end-expiratory levels and with similar efforts. In the cranial thorax plane the normalized ΔI_E_R_V/ERV ratio in all subjects was significantly higher than the normalized ΔI_I_R_V/IRV ratio whereas the opposite was found in the caudal chest plane. No significant difference between the two normalized ratios was found in the middle thoracic plane. Depending on electrode positioning, impedance to volume ratios may either increase or decrease in the same lung condition, which may lead to opposite clinical decisions. (paper)

  6. The Society for Translational Medicine: clinical practice guidelines for mechanical ventilation management for patients undergoing lobectomy.

    Science.gov (United States)

    Gao, Shugeng; Zhang, Zhongheng; Brunelli, Alessandro; Chen, Chang; Chen, Chun; Chen, Gang; Chen, Haiquan; Chen, Jin-Shing; Cassivi, Stephen; Chai, Ying; Downs, John B; Fang, Wentao; Fu, Xiangning; Garutti, Martínez I; He, Jianxing; He, Jie; Hu, Jian; Huang, Yunchao; Jiang, Gening; Jiang, Hongjing; Jiang, Zhongmin; Li, Danqing; Li, Gaofeng; Li, Hui; Li, Qiang; Li, Xiaofei; Li, Yin; Li, Zhijun; Liu, Chia-Chuan; Liu, Deruo; Liu, Lunxu; Liu, Yongyi; Ma, Haitao; Mao, Weimin; Mao, Yousheng; Mou, Juwei; Ng, Calvin Sze Hang; Petersen, René H; Qiao, Guibin; Rocco, Gaetano; Ruffini, Erico; Tan, Lijie; Tan, Qunyou; Tong, Tang; Wang, Haidong; Wang, Qun; Wang, Ruwen; Wang, Shumin; Xie, Deyao; Xue, Qi; Xue, Tao; Xu, Lin; Xu, Shidong; Xu, Songtao; Yan, Tiansheng; Yu, Fenglei; Yu, Zhentao; Zhang, Chunfang; Zhang, Lanjun; Zhang, Tao; Zhang, Xun; Zhao, Xiaojing; Zhao, Xuewei; Zhi, Xiuyi; Zhou, Qinghua

    2017-09-01

    Patients undergoing lobectomy are at significantly increased risk of lung injury. One-lung ventilation is the most commonly used technique to maintain ventilation and oxygenation during the operation. It is a challenge to choose an appropriate mechanical ventilation strategy to minimize the lung injury and other adverse clinical outcomes. In order to understand the available evidence, a systematic review was conducted including the following topics: (I) protective ventilation (PV); (II) mode of mechanical ventilation [e.g., volume controlled (VCV) versus pressure controlled (PCV)]; (III) use of therapeutic hypercapnia; (IV) use of alveolar recruitment (open-lung) strategy; (V) pre-and post-operative application of positive end expiratory pressure (PEEP); (VI) Inspired Oxygen concentration; (VII) Non-intubated thoracoscopic lobectomy; and (VIII) adjuvant pharmacologic options. The recommendations of class II are non-intubated thoracoscopic lobectomy may be an alternative to conventional one-lung ventilation in selected patients. The recommendations of class IIa are: (I) Therapeutic hypercapnia to maintain a partial pressure of carbon dioxide at 50-70 mmHg is reasonable for patients undergoing pulmonary lobectomy with one-lung ventilation; (II) PV with a tidal volume of 6 mL/kg and PEEP of 5 cmH 2 O are reasonable methods, based on current evidence; (III) alveolar recruitment [open lung ventilation (OLV)] may be beneficial in patients undergoing lobectomy with one-lung ventilation; (IV) PCV is recommended over VCV for patients undergoing lung resection; (V) pre- and post-operative CPAP can improve short-term oxygenation in patients undergoing lobectomy with one-lung ventilation; (VI) controlled mechanical ventilation with I:E ratio of 1:1 is reasonable in patients undergoing one-lung ventilation; (VII) use of lowest inspired oxygen concentration to maintain satisfactory arterial oxygen saturation is reasonable based on physiologic principles; (VIII) Adjuvant drugs

  7. Actual performance of mechanical ventilators in ICU: a multicentric quality control study.

    Science.gov (United States)

    Govoni, Leonardo; Dellaca', Raffaele L; Peñuelas, Oscar; Bellani, Giacomo; Artigas, Antonio; Ferrer, Miquel; Navajas, Daniel; Pedotti, Antonio; Farré, Ramon

    2012-01-01

    Even if the performance of a given ventilator has been evaluated in the laboratory under very well controlled conditions, inappropriate maintenance and lack of long-term stability and accuracy of the ventilator sensors may lead to ventilation errors in actual clinical practice. The aim of this study was to evaluate the actual performances of ventilators during clinical routines. A resistance (7.69 cmH(2)O/L/s) - elastance (100 mL/cmH(2)O) test lung equipped with pressure, flow, and oxygen concentration sensors was connected to the Y-piece of all the mechanical ventilators available for patients in four intensive care units (ICUs; n = 66). Ventilators were set to volume-controlled ventilation with tidal volume = 600 mL, respiratory rate = 20 breaths/minute, positive end-expiratory pressure (PEEP) = 8 cmH(2)O, and oxygen fraction = 0.5. The signals from the sensors were recorded to compute the ventilation parameters. The average ± standard deviation and range (min-max) of the ventilatory parameters were the following: inspired tidal volume = 607 ± 36 (530-723) mL, expired tidal volume = 608 ± 36 (530-728) mL, peak pressure = 20.8 ± 2.3 (17.2-25.9) cmH(2)O, respiratory rate = 20.09 ± 0.35 (19.5-21.6) breaths/minute, PEEP = 8.43 ± 0.57 (7.26-10.8) cmH(2)O, oxygen fraction = 0.49 ± 0.014 (0.41-0.53). The more error-prone parameters were the ones related to the measure of flow. In several cases, the actual delivered mechanical ventilation was considerably different from the set one, suggesting the need for improving quality control procedures for these machines.

  8. predicted peak expiratory flow in human and the clinical implication ...

    African Journals Online (AJOL)

    DR. AMINU

    predicted PEF varied widely across formulae and choice of a particular formula may alter guideline- base care. This work has therefore accepted a recently published population-base equation proposed as the reference standard for future asthma guidelines. Keywords: Peak expiratory flow, Asthma, Practice guidelines, ...

  9. ARDS: challenges in patient care and frontiers in research

    Directory of Open Access Journals (Sweden)

    Lieuwe D. Bos

    2018-01-01

    Full Text Available This review discusses the clinical challenges associated with ventilatory support and pharmacological interventions in patients with acute respiratory distress syndrome (ARDS. In addition, it discusses current scientific challenges facing researchers when planning and performing trials of ventilatory support or pharmacological interventions in these patients. Noninvasive mechanical ventilation is used in some patients with ARDS. When intubated and mechanically ventilated, ARDS patients should be ventilated with low tidal volumes. A plateau pressure <30 cmH2O is recommended in all patients. It is suggested that a plateau pressure <15 cmH2O should be considered safe. Patient with moderate and severe ARDS should receive higher levels of positive end-expiratory pressure (PEEP. Rescue therapies include prone position and neuromuscular blocking agents. Extracorporeal support for decapneisation and oxygenation should only be considered when lung-protective ventilation is no longer possible, or in cases of refractory hypoxaemia, respectively. Tracheotomy is only recommended when prolonged mechanical ventilation is expected. Of all tested pharmacological interventions for ARDS, only treatment with steroids is considered to have benefit. Proper identification of phenotypes, known to respond differently to specific interventions, is increasingly considered important for clinical trials of interventions for ARDS. Such phenotypes could be defined based on clinical parameters, such as the arterial oxygen tension/inspiratory oxygen fraction ratio, but biological marker profiles could be more promising.

  10. Adjusting tidal volume to stress index in an open lung condition optimizes ventilation and prevents overdistension in an experimental model of lung injury and reduced chest wall compliance.

    Science.gov (United States)

    Ferrando, Carlos; Suárez-Sipmann, Fernando; Gutierrez, Andrea; Tusman, Gerardo; Carbonell, Jose; García, Marisa; Piqueras, Laura; Compañ, Desamparados; Flores, Susanie; Soro, Marina; Llombart, Alicia; Belda, Francisco Javier

    2015-01-13

    The stress index (SI), a parameter derived from the shape of the pressure-time curve, can identify injurious mechanical ventilation. We tested the hypothesis that adjusting tidal volume (VT) to a non-injurious SI in an open lung condition avoids hypoventilation while preventing overdistension in an experimental model of combined lung injury and low chest-wall compliance (Ccw). Lung injury was induced by repeated lung lavages using warm saline solution, and Ccw was reduced by controlled intra-abdominal air-insufflation in 22 anesthetized, paralyzed and mechanically ventilated pigs. After injury animals were recruited and submitted to a positive end-expiratory pressure (PEEP) titration trial to find the PEEP level resulting in maximum compliance. During a subsequent four hours of mechanical ventilation, VT was adjusted to keep a plateau pressure (Pplat) of 30 cmH2O (Pplat-group, n = 11) or to a SI between 0.95 and 1.05 (SI-group, n = 11). Respiratory rate was adjusted to maintain a 'normal' PaCO2 (35 to 65 mmHg). SI, lung mechanics, arterial-blood gases haemodynamics pro-inflammatory cytokines and histopathology were analyzed. In addition Computed Tomography (CT) data were acquired at end expiration and end inspiration in six animals. PaCO2 was significantly higher in the Pplat-group (82 versus 53 mmHg, P = 0.01), with a resulting lower pH (7.19 versus 7.34, P = 0.01). We observed significant differences in VT (7.3 versus 5.4 mlKg(-1), P = 0.002) and Pplat values (30 versus 35 cmH2O, P = 0.001) between the Pplat-group and SI-group respectively. SI (1.03 versus 0.99, P = 0.42) and end-inspiratory transpulmonary pressure (PTP) (17 versus 18 cmH2O, P = 0.42) were similar in the Pplat- and SI-groups respectively, without differences in overinflated lung areas at end- inspiration in both groups. Cytokines and histopathology showed no differences. Setting tidal volume to a non-injurious stress index in an open lung condition improves

  11. Knowledge, attitude and practice of nurses toward peak expiratory ...

    African Journals Online (AJOL)

    Background: Peak expiratory flow meter (PEFM) is an easy to use, relatively cheap device that can be used for guiding management of bronchial asthma by the patients at home according to a preset plan by health care workers. Objective: The aim of the study is to reveal the extent of knowledge and perception of nurses ...

  12. Uus töölpeinguseadus : nagu Soomes lama ajal? Ei, veel karmim / Maret Maripuu, Tarmo Kriis, Peep Peterson ; interv. Külli-Riin Tigasson

    Index Scriptorium Estoniae

    Maripuu, Maret, 1974-

    2008-01-01

    Uue töölepingu seaduse eelnõust. Vestlusringis on sotsiaalminister Maret Maripuu, Eesti tööandjate keskliidu juhataja Tarmo Kriis ja transpordi ametiühingu juhatuse esimees Peep Peterson. Lisatud: mida eelnõu muudab? ; ametiühingute keskliidu juhi Harri Taliga kommentaar: dzhungliseaduste tagasitulek? ; Helmes ASi nõukogu esimehe Jaan Pillesaare kommentaar: praegune seadus on tobe

  13. Ventilation practices in subarachnoid hemorrhage: a cohort study exploring the use of lung protective ventilation.

    Science.gov (United States)

    Marhong, Jonathan D; Ferguson, Niall D; Singh, Jeffrey M

    2014-10-01

    Acute respiratory distress syndrome (ARDS) is common following aneurysmal subarachnoid hemorrhage (SAH), but the influence of mechanical ventilator settings on its development is unclear. We sought to determine adherence to lung protective thresholds in ventilated patients with SAH and describe the association between ventilator settings and subsequent development of ARDS. We conducted a retrospective cohort study of consecutive patients receiving mechanical ventilation within 72 h of SAH at a single academic center. Ventilator settings and blood gas data were collected twice daily for the first 7 days of ventilation along with ICU and hospital outcomes. Lung protective ventilation was defined as follows: tidal volume ≤8 mL/kg of predicted body weight, positive end-expiratory pressure (PEEP) ≥5 cm H(2)O, and peak or plateau pressure ≤30 cm H(2)O. The development of ARDS was ascertained retrospectively by PaO(2)/FiO(2) ≤300 with new bilateral lung opacities on chest X-ray within one day of hypoxemia. We identified 62 patients who underwent early mechanical ventilation following SAH. PS and Continuous Positive Airway Pressure were common ventilator modes with a median tidal volume of 7.8 mL/kg [interquartile range 6.8-8.8], median peak pressure of 14 cm H(2)O [IQR 12-17], and median PEEP of 5 cm H(2)O [IQR 5-6]. Adherence to tidal volumes ≤8 mL/kg was seen in 64 % of all observations and peak pressures protective criteria were seen in 58 % of all observations. Thirty-one patients (50 %) were determined to have ARDS. ARDS patients were more frequently ventilated with a peak pressure >30 cm H(2)O (11.3 % of ARDS ventilation days vs. 0 % of non-ARDS ventilation days; p mechanical ventilation frequently breathe spontaneously, generating tidal volumes above usual protective thresholds regardless of meeting ARDS criteria. In patients with SAH, the presence of an additional ARDS risk factor should prompt close screening for the development of ARDS and

  14. Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure.

    Science.gov (United States)

    Cordioli, Ricardo Luiz; Park, Marcelo; Costa, Eduardo Leite Vieira; Gomes, Susimeire; Brochard, Laurent; Amato, Marcelo Britto Passos; Azevedo, Luciano Cesar Pontes

    2014-12-01

    The aim of this study was to explore if positive-pressure ventilation delivered by a conventional ICU ventilator at a moderately high frequency (HFPPV) allows a safe reduction of tidal volume (V T) below 6 mL/kg in a porcine model of severe acute respiratory distress syndrome (ARDS) and at a lower mean airway pressure than high-frequency oscillatory ventilation (HFOV). This is a prospective study. In eight pigs (median weight 34 [29,36] kg), ARDS was induced by pulmonary lavage and injurious ventilation. The animals were ventilated with a randomized sequence of respiratory rates: 30, 60, 90, 120, 150, followed by HFOV at 5 Hz. At each step, V T was adjusted to allow partial pressure of arterial carbon dioxide (PaCO2) to stabilize between 57 and 63 mmHg. Data are shown as median [P25th,P75th]. After lung injury, the PaO2/FiO2 (P/F) ratio was 92 [63,118] mmHg, pulmonary shunt 26 [17,31]%, and static compliance 11 [8,14] mL/cmH2O. Positive end-expiratory pressure (PEEP) was 14 [10,17] cmH2O. At 30 breaths/min, V T was higher than 6 (7.5 [6.8,10.2]) mL/kg, but at all higher frequencies, V T could be reduced and PaCO2 maintained, leading to reductions in plateau pressures and driving pressures. For frequencies of 60 to 150/min, V T progressively fell from 5.2 [5.1,5.9] to 3.8 [3.7,4.2] mL/kg (p mechanics, auto-PEEP generation, hemodynamics, or gas exchange. Mean airway pressure was maintained constant and was increased only during HFOV. During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model safely allows further tidal volume reductions. This strategy also allowed decreasing airway pressures while maintaining stable PaCO2 levels.

  15. Evaluation of Peak Expiratory Flow Rates (PEFR) of Workers in a ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    and knowledge of occupational health associated with the ... the respiratory system with significant. 5 ... Peak Expiratory Flow Rates (PEFR) of workers in a cement factory — Douglas K. E, Alasia D. D. ... history of cigarette smoking and chronic.

  16. Impact of humidification and nebulization during expiratory limb protection: an experimental bench study.

    Science.gov (United States)

    Tonnelier, Alexandre; Lellouche, François; Bouchard, Pierre Alexandre; L'Her, Erwan

    2013-08-01

    Different filtering devices are used during mechanical ventilation to avoid dysfunction of flow and pressure transducers or for airborne microorganisms containment. Water condensates, resulting from the use of humidifiers, but also residual nebulization particles may have a major influence on expiratory limb resistance. To evaluate the influence of nebulization and active humidification on the resistance of expiratory filters. A respiratory system analog was constructed using a test lung, an ICU ventilator, heated humidifiers, and a piezoelectric nebulizer. Humidifiers were connected to different types of circuits (unheated, mono-heated, new-generation and old-generation bi-heated). Five filter types were evaluated: electrostatic, heat-and-moisture exchanger, standard, specific, and internal heated high-efficiency particulate air [HEPA] filter. Baseline characteristics were obtained from each dry filter. Differential pressure measurements were carried out after 24 hours of continuous in vitro use for each condition, and after 24 hours of use with an old-generation bi-heated circuit without nebulization. While using unheated circuits, measurements had to be interrupted before 24 hours for all the filtering devices except the internal heated HEPA filter. The heat-and-moisture exchangers occluded before 24 hours with the unheated and mono-heated circuits. The circuit type, nebulization practice, and duration of use did not influence the internal heated HEPA filter resistance. Expiratory limb filtration is likely to induce several major adverse events. Expiratory filter resistance increase is due mainly to the humidification circuit type, rather than to nebulization. If filtration is mandatory while using an unheated circuit, a dedicated filter should be used for ≤ 24 hours, or a heated HEPA for a longer duration.

  17. Eesti mood esitles end Stockholmis / Peep Sooman

    Index Scriptorium Estoniae

    Sooman, Peep, 1978-

    1999-01-01

    Eesti moepäevadel Stockholmis esitleti moeshow'l üle 80 rõivakollektsiooni, osalesid: Baltika, Klementi, Sangar, Zik-Zak (Ivo Nikkolo), Katrin Kuldma Moemaja, Arne Studio, Hipo, Uljas & Tütred, Virulane, Althea.

  18. Gamma-variate modeling of indicator dilution curves in electrical impedance tomography.

    Science.gov (United States)

    Hentze, Benjamin; Muders, Thomas; Luepschen, Henning; Leonhardt, Steffen; Putensen, Christian; Walter, Marian

    2017-07-01

    Electrical impedance tomography (EIT) is a non-invasive imaging technique, that can be used to monitor regional lung ventilation (V̇) in intensive care units (ICU) at bedside. This work introduces a method to extract regional lung perfusion (Q̇) from EIT image streams in order to quantify regional gas exchange in the lungs. EIT data from a single porcine animal trial, recorded during injection of a contrast agent (NaCl 10%) into a central venous catheter (CVC), are used for evaluation. Using semi-negative matrix factorization (Semi-NMF) a set of source signals is extracted from the data. A subsequent non-linear fit of a gamma-variate model to the source signals results in model signals, describing contrast agent flow through the cardio-pulmonary system. A linear fit of the model signals to the EIT image stream then yields functional images ofQ̇. Additionally, a pulmonary transit function (PTF) and parameters, such as mean transit time (MTT), time to peak (TTP) and area under curve (AUC) are derived. In result, EIT was used to track changes of regional lung ventilation to perfusion ratio (V̇/Q̇) during changes of positive end-expiratory pressure (PEEP). Furthermore, correlations of MTT and AUC with cardiac output (CO) indicate that CO measurement by EIT might be possible.

  19. Effects of positive expiratory pressure on pulmonary clearance of aerosolized technetium-{sup 99m}-labeled diethylenetriaminepentaacetic acid in healthy individuals

    Energy Technology Data Exchange (ETDEWEB)

    Albuquerque, Isabella Martins de, E-mail: albuisa@gmail.com [Universidade Federal de Santa Maria (UFSM), Santa Maria, RS (Brazil). Departamento de Fisioterapia e Reabilitacao; Cardoso, Dannuey Machado; Paiva, Dulciane Nunes [Universidade de Santa Cruz do Sul, RS (Brazil); Masiero, Paulo Ricardo; Menna-Barreto, Sergio Saldanha [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre (Brazil); Resqueti, Vanessa Regiane; Fregonezi, Guilherme Augusto de Freitas [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)

    2016-11-15

    Objective: To evaluate the effects of positive expiratory pressure (PEP) on pulmonary epithelial membrane permeability in healthy subjects. Methods: We evaluated a cohort of 30 healthy subjects (15 males and 15 females) with a mean age of 28.3 ± 5.4 years, a mean FEV{sub 1}/FVC ratio of 0.89 ± 0.14, and a mean FEV{sub 1} of 98.5 ± 13.1% of predicted. Subjects underwent technetium-99m labeled diethylenetriaminepentaacetic acid ({sup 99m}TcDTPA) radio aerosol inhalation lung scintigraphy in two stages: during spontaneous breathing; and while breathing through a PEP mask at one of three PEP levels—10 cmH{sub 2}O (n = 10), 15 cmH{sub 2}O (n = 10), and 20 cmH{sub 2}O (n = 10). The {sup 99m}Tc-DTPA was nebulized for 3 min, and its clearance was recorded by scintigraphy over a 30-min period during spontaneous breathing and over a 30-min period during breathing through a PEP mask. Results: The pulmonary clearance of {sup 99m}Tc-DTPA was significantly shorter when PEP was applied—at 10 cmH{sub 2}O (p = 0.044), 15 cmH{sub 2}O (p = 0.044), and 20 cmH{sub 2}O (p = 0.004) - in comparison with that observed during spontaneous breathing. Conclusions: Our findings indicate that PEP, at the levels tested, is able to induce an increase in pulmonary epithelial membrane permeability and lung volume in healthy subjects. (author)

  20. Between preservation and transformation. First considerations about the recovery of the peep districts in Parma

    Directory of Open Access Journals (Sweden)

    Luca Gullì

    2012-10-01

    Full Text Available The regeneration policy of the PEEP districts, can contribute to the enrichment of the theoretical framework formulated for the protection of the heritage of the Modern Movement. In 2011, the Municipality of Parma, showing a new awareness in relation to assets until now rarely considered, devices a specific field of study within its structural urbanistic plan. In the absence of a regulatory framework of reference, it is crucial to build up the appropriate frameworks of knowledge directed to operational decisions. This can be done by specifically dedicated archives to which to entrust with the definition of a body of rules of urban planning and housing tailored to the particularities of these settlements and to the real questions of transformation that can arise in them.

  1. Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study.

    Science.gov (United States)

    Dahl, Michael K; Vistisen, Simon T; Koefoed-Nielsen, Jacob; Larsson, Anders

    2009-01-01

    Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypothesized that during spontaneous breathing, inspiratory and/or expiratory resistors could induce high arterial pressure variations at hypovolemia and low variations at normovolemia and hypervolemia. Furthermore, we hypothesized that SPV and PPV could predict fluid responsiveness under these conditions. Eight prone, anesthetized and spontaneously breathing pigs (20 to 25 kg) were subjected to a sequence of 30% hypovolemia, normovolemia, and 20% and 40% hypervolemia. At each volemic level, the pigs breathed in a randomized order either through an inspiratory and/or an expiratory threshold resistor (7.5 cmH2O) or only through the tracheal tube without any resistor. Hemodynamic and respiratory variables were measured during the breathing modes. Fluid responsiveness was defined as a 15% increase in stroke volume (DeltaSV) following fluid loading. Stroke volume was significantly lower at hypovolemia compared with normovolemia, but no differences were found between normovolemia and 20% or 40% hypervolemia. Compared with breathing through no resistor, SPV was magnified by all resistors at hypovolemia whereas there were no changes at normovolemia and hypervolemia. PPV was magnified by the inspiratory resistor and the combined inspiratory and expiratory resistor. Regression analysis of SPV or PPV versus DeltaSV showed the highest R2 (0.83 for SPV and 0.52 for PPV) when the expiratory resistor was applied. The corresponding sensitivity and specificity for prediction of fluid responsiveness were 100% and 100%, respectively, for SPV and 100% and 81%, respectively, for PPV. Inspiratory and/or expiratory threshold resistors magnified SPV and PPV in spontaneously breathing pigs during hypovolemia

  2. The Concave Shape of the Forced Expiratory Flow-Volume Curve in 3 Seconds Is a Practical Surrogate of FEV1/FVC for the Diagnosis of Airway Limitation in Inadequate Spirometry.

    Science.gov (United States)

    Li, Hao; Liu, Chunhong; Zhang, Yi; Xiao, Wei

    2017-03-01

    Spirometry is important for the differential diagnosis of dyspnea. However, some patients cannot exhale for ≥6 s to achieve the American Thoracic Society/European Respiratory Society criteria. The aim of this study was to demonstrate the reliability of a new parameter that quantifies the degree of concavity in the first 3 s to define airway limitation as a surrogate for the FEV 1 /FVC. Four hundred spirometry test results were selected through complete random sampling. The new parameter, termed the AUC 3 /AT 3 , was calculated as the area under the descending limb of the expiratory flow-volume curve before the end of the first 3 s (AUC 3 ) divided by the area of the triangle before the end of the first 3 s (AT 3 ). The AUC 3 /AT 3 was compared with the FEV 1 /FVC using Pearson's correlation analysis. The level of agreement between the AUC 3 /AT 3 and the FEV 1 /FVC in the detection of airway obstruction was analyzed using the kappa statistic. We also compared the diagnostic accuracy of the new index with that of the FEV 1 /forced expiratory volume in the first 3 s (FEV 3 ). There was a strong correlation (r = 0.88, P < .001) between the AUC 3 /AT 3 and the FEV 1 /FVC. There was also strong agreement between the AUC 3 /AT 3 and the FEV 1 /FVC in the detection of obstruction with kappa indices of 0.72 (Global Initiative for Chronic Obstructive Lung Disease [GOLD] criterion) and 0.67 (lower limit of normal criterion), and these values were greater than those obtained for the FEV 1 /FEV 3 . The AUC 3 /AT 3 also exhibited acceptable sensitivity, specificity, positive predictive value, and negative predictive value. The diagnostic accuracies of the AUC 3 /AT 3 were 86.3% (GOLD criterion) and 83.8% (lower limit of normal criterion), which were greater than the 76.0 and 74.0% obtained for the FEV 1 /FEV 3 , respectively. The AUC 3 /AT 3 can be utilized as a surrogate parameter for the FEV 1 /FVC when patients cannot complete a 6-s expiratory effort. Additionally, the

  3. Effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by parkinson's disease.

    Science.gov (United States)

    Byeon, Haewon

    2016-06-01

    [Purpose] This study aimed to investigate the effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by Parkinson's disease. [Subjects and Methods] The subjects of this study were 18 patients who received simultaneous application of postural techniques and expiratory muscle strength training and 15 patients who received expiratory muscle strength training only. Postural techniques were conducted in the order of chin tucking, head rotation, head tilting, bending head back, and lying down, while expiratory muscle strength training was conducted at a resistance level of about 70% of the maximal expiratory pressure. Swallowing recovery was assessed by using the Functional Dysphagia Scale based on videofluoroscopic studies. [Results] The mean value obtained in the videofluoroscopic studies for both groups decreased after the treatment. In the postural techniques plus expiratory muscle strength training group, the decrease was significantly greater than that in the expiratory muscle strength training-only group. [Conclusion] The results imply that simultaneous performance of postural techniques and expiratory muscle strength training is more effective than expiratory muscle strength training alone when applied in the swallowing rehabilitation for patients with dysphagia caused by Parkinson's disease.

  4. Age group classification and gender detection based on forced expiratory spirometry.

    Science.gov (United States)

    Cosgun, Sema; Ozbek, I Yucel

    2015-08-01

    This paper investigates the utility of forced expiratory spirometry (FES) test with efficient machine learning algorithms for the purpose of gender detection and age group classification. The proposed method has three main stages: feature extraction, training of the models and detection. In the first stage, some features are extracted from volume-time curve and expiratory flow-volume loop obtained from FES test. In the second stage, the probabilistic models for each gender and age group are constructed by training Gaussian mixture models (GMMs) and Support vector machine (SVM) algorithm. In the final stage, the gender (or age group) of test subject is estimated by using the trained GMM (or SVM) model. Experiments have been evaluated on a large database from 4571 subjects. The experimental results show that average correct classification rate performance of both GMM and SVM methods based on the FES test is more than 99.3 % and 96.8 % for gender and age group classification, respectively.

  5. Is there an optimal level of positive expiratory pressure (PEP) to improve walking tolerance in patients with severe COPD?

    Science.gov (United States)

    Russo, Davide; Simonelli, Carla; Paneroni, Mara; Saleri, Manuela; Piroddi, Ines Maria Grazia; Cardinale, Francesco; Vitacca, Michele; Nicolini, Antonello

    2016-07-01

    The application of positive expiratory pressure (PEP) devices during exercise had been proposed in order to counteract the pulmonary hyperinflation, reduce the dyspnea and thus increase the exercise tolerance in patients with severe chronic obstructive pulmonary disease (COPD). This randomized controlled crossover trial investigated the effect of two different levels of PEP (1 cmH2O and 10 cmH2O) on distance covered at 6minute walk test (6MWT) in patients with severe COPD. Secondary outcomes were the evaluation of PEP effects on physiological and pulmonary function variables. Seventy-two severe COPD patients, referred to our hospitals as in and out patients, were recruited. A basal 6MWT without devices was performed on the first day, and then repeated with PEP 1 cmH2O (PEP1) and 10 cmH2O (PEP10), with a randomized crossover design. Slow and forced spirometries, including the inspiratory capacity measure, were repeated before and after each 6MWT. 50 patients (average age 69,92 year, mean FEV1 41,42% of predicted) concluded the trial. The 6MWT improved significantly among both PEP levels and baseline (323,8 mt at baseline vs. 337,8 PEP1 and 341,8 PEP10; p<.002 and p<.018, respectively). The difference between PEP10 and PEP1 did not reach the significance. No improvements were found in pulmonary function, symptoms and physiological variables after the 6MWT. In patients with severe COPD, the application of 1 cmH2O of PEP seems to improve the exercise tolerance as 10 cmH2O, with similar dyspnea. Further studies should investigate the effects of low levels of PEP on aerobic training programs. Copyright © 2016 SEPAR. Published by Elsevier Espana. All rights reserved.

  6. Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies

    International Nuclear Information System (INIS)

    Zompatori, Maurizio; Battaglia, Milva; Rimondi, Maria Rita; Vivacqua, Donatella; Biscarini, Manuela; Fasano, Luca; Pacilli, Angela Maria Grazia; Guerrieri, Aldo; Fabbri, Mario; Cavina, Mauro

    1997-01-01

    CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas diffusion impairment (visual score versus forced expiratory volume in one second: r = -0.81, versus single breath carbon monoxide diffusion: r = -0.78. Spiral expiratory density mask -850 HU versus forced expiratory volume in one second: r = -0.85 versus single breath carbon monoxide diffusion: r = -0.77). When -900 HU was used as the cut-off value for the expiratory density mask, the correlation with single breath carbon monoxide diffusion worsened (r = -0.56). Visual score and expiratory density mask -850 HU gave similar results and permitted COPD patients to be clearly distinguished from normal controls (p < 0.01). They believe the true residual volume should lie somewhere in between the CT value and the function results with the helium dilution technique and conclude that the extent of pulmonary emphysema can be confidently assessed with CT methods. Finally, the simple visual score may be as reliable as such highly sophisticated new methods as the spiral expiratory density mask

  7. Influência da técnica de pressão expiratória positiva oscilante utilizando pressões expiratórias pré-determinadas na viscosidade e na transportabilidade do escarro em pacientes com bronquiectasia Influence that oscillating positive expiratory pressure using predetermined expiratory pressures has on the viscosity and transportability of sputum in patients with bronchiectasis

    Directory of Open Access Journals (Sweden)

    Ercy Mara Cipulo Ramos

    2009-12-01

    Full Text Available OBJETIVO: Verificar a efetividade da técnica de pressão expiratória positiva oscilante (PEPO utilizando pressões expiratórias pré-determinadas sobre a viscosidade e a transportabilidade do escarro em pacientes com bronquiectasia. MÉTODOS: Foram incluídos no estudo 15 pacientes estáveis com bronquiectasia (7 homens; média de idade = 53 ± 16 anos, submetidos a duas intervenções PEPO consecutivas, com 24 h de intervalo entre si, utilizando pressões expiratórias de 15 cmH2O (P15 e 25 cmH2O (P25. O protocolo consistiu de tosse voluntária; nova expectoração voluntária após 20 min, denominado tempo zero (T0; repouso de 10 min; e utilização da técnica em duas séries de 10 min (S1 e S2 de PEPO em P15 e P25, com intervalo de 10 min entre si. A viscosidade e transportabilidade do escarro foram avaliadas pela viscosimetria, velocidade relativa de transporte no palato de rã, deslocamento em máquina simuladora de tosse e ângulo de adesão. As amostras de escarro foram coletadas em T0, após S1 e após S2. Testes estatísticos específicos foram aplicados de acordo com a distribuição dos dados. RESULTADOS: Houve diminuição significante da viscosidade do escarro após S1 em P15 e após S2 em P25. Não houve diferenças significantes entre todas as amostras para a transportabilidade. CONCLUSÕES: Houve diminuição da viscosidade do escarro quando a PEPO foi realizada em P15 e P25, o que sugere que não seja necessário gerar alta pressão expiratória para obter o resultado desejado.OBJECTIVE: To determine the effectiveness of oscillating positive expiratory pressure (OPEP using predetermined expiratory pressures on the viscosity and transportability of sputum in patients with bronchiectasis. METHODS: The study involved 15 stable patients with bronchiectasis (7 males; mean age = 53 ± 16 years, submitted to two consecutive OPEP interventions, with a 24-h interval between the two, using positive expiratory pressures set at 15 cmH2O

  8. Hand grip strength and maximum peak expiratory flow: determinants of bone mineral density of adolescent students.

    Science.gov (United States)

    Cossio-Bolaños, Marco; Lee-Andruske, Cynthia; de Arruda, Miguel; Luarte-Rocha, Cristian; Almonacid-Fierro, Alejandro; Gómez-Campos, Rossana

    2018-03-02

    Maintaining and building healthy bones during the lifetime requires a complicated interaction between a number of physiological and lifestyle factors. Our goal of this study was to analyze the association between hand grip strength and the maximum peak expiratory flow with bone mineral density and content in adolescent students. The research team studied 1427 adolescent students of both sexes (750 males and 677 females) between the ages of 11.0 and 18.9 years in the Maule Region of Talca (Chile). Weight, standing height, sitting height, hand grip strength (HGS), and maximum peak expiratory flow (PEF) were measured. Furthermore, bone mineral density (BMD) and total body bone mineral content (BMC) were determined by using the Dual-Energy X-Ray Absorptiometry (DXA). Hand grip strength and PEF were categorized in tertiles (lowest, middle, and highest). Linear regression was performed in steps to analyze the relationship between the variables. Differences between categories were determined through ANOVA. In males, the hand grip strength explained 18-19% of the BMD and 20-23% of the BMC. For the females, the percentage of variation occurred between 12 and 13% of the BMD and 17-18% of the BMC. The variation of PEF for the males was observed as 33% of the BMD and 36% of the BMC. For the females, both the BMD and BMC showed a variation of 19%. The HGS and PEF were divided into three categories (lowest, middle, and highest). In both cases, significant differences occurred in bone density health between the three categories. In conclusion, the HGS and the PEF related positively to the bone density health of both sexes of adolescent students. The adolescents with poor values for hand grip strength and expiratory flow showed reduced values of BMD and BMC for the total body. Furthermore, the PEF had a greater influence on bone density health with respect to the HGS of the adolescents of both sexes.

  9. A bench evaluation of fraction of oxygen in air delivery and tidal volume accuracy in home care ventilators available for hospital use

    Science.gov (United States)

    Baboi, Loredana; Subtil, Fabien

    2016-01-01

    Background Turbine-powered ventilators are not only designed for long-term ventilation at home but also for hospital use. It is important to verify their capabilities in delivering fraction of oxygen in air (FIO2) and tidal volume (VT). Methods We assessed the FIO2 accuracy and the VT delivery in four home care ventilators (HCV) on the bench. The four HCV were Astral 150, Elisée 150, Monnal T50 and Trilogy 200 HCV, which were connected to a lung model (ASL 5000). For assessing FIO2 accuracy, lung model was set to mimic an obstructive lung and HCV were set in volume controlled mode (VC). They supplied with air, 3 or 15 L/min oxygen and FIO2 was measured by using a ventilator tester (Citrex H4TM). For the VT accuracy, the lung model was set in a way to mimic three adult configurations (normal, obstructive, or restrictive respiratory disorder) and one pediatric configuration. Each HCV was set in VC. Two VT (300 and 500 mL) in adult lung configuration and one 50 mL VT in pediatric lung configuration, at two positive end expiratory pressures 5 and 10 cmH2O, were tested. VT accuracy was measured as volume error (the relative difference between set and measured VT). Statistical analysis was performed by suing one-factor ANOVA with a Bonferroni correction for multiple tests. Results For Astral 150, Elisée 150, Monnal T50 and Trilogy 200, FIO2 averaged 99.2%, 93.7%, 86.3%, and 62.1%, respectively, at 15 L/min oxygen supplementation rate (P<0.001). Volume error was 0.5%±0%, −38%±0%, −9%±0%, −29%±0% and −36%±0% for pediatric lung condition (P<0.001). In adult lung configurations, Monnal T50 systematically over delivered VT and Trilogy 150 was sensitive to lung configuration when VT was set to 300 mL at either positive end-expiratory pressure (PEEP). Conclusions HCV are different in terms of FIO2 efficiency and VT delivery. PMID:28149559

  10. Influencia del reclutamiento alveolar sobre los efectos del surfactante exógeno Influence of pulmonary recruitment on exogenous surfactant effects

    Directory of Open Access Journals (Sweden)

    Néstor R. Herrera

    2006-02-01

    response to exogenous surfactant administration and the effects of baseline pulmonary volume subsequently used in 20 adult albino rats. Lung-injury was induced by repeated lavages with saline solution. Gas exchange, hemodynamic status, lung mechanics and histopathology were assessed. The rats were divided into four experimental groups. Group 1 was delivered 30 cmH2O sustained insufflation over 15 seconds prior to the surfactant. It was subsequently ventilated at positive end-expiratory pressure (PEEP of 10 cm H2O. Group 2 did not receive sustained insufflation and was ventilated at PEEP of 10 cm H2O. Group 3 was delivered sustained insufflation and was ventilated with PEEP of 4 cm H2O; and group 4 did not receive sustained insufflation and was ventilated with PEEP of 4 cm H2O. The surfactant immediate effect was not modified by previous sustained insufflation administration. Increased PaO2 associated to high functional residual capacity (FRC (Group 1 p=0.0001; Group 2 p=0.0001, regardless of sustained insufflation, was observed. The use of sustained insufflation prior to surfactant administration along with high FRC ventilation was associated with polymorphonuclear infiltrates beneath the bronchiolar epithelium (p=0.008. Our results do not advocate the use of sustained insufflation prior to the administration of exogenous surfactant.

  11. Predictors of response to a nasal expiratory resistor device and its potential mechanisms of action for treatment of obstructive sleep apnea.

    Science.gov (United States)

    Patel, Amit V; Hwang, Dennis; Masdeu, Maria J; Chen, Guo-Ming; Rapoport, David M; Ayappa, Indu

    2011-02-15

    A one-way nasal resistor has recently been shown to reduce sleep disordered breathing (SDB) in a subset of patients with Obstructive Sleep Apnea Hypopnea Syndrome (OSAHS). The purpose of this study was to examine characteristics predictive of therapeutic response to the device and provide pilot data as to its potential mechanisms of action. PATIENTS, INTERVENTIONS, AND MEASUREMENTS: 20 subjects (15M/5F, age 54 ± 12 years, BMI 33.5 ± 5.6 kg/m²) with OSAHS underwent 3 nocturnal polysomnograms (NPSG) including diagnostic, therapeutic (with a Provent® nasal valve device), and CPAP. Additional measurements included intranasal pressures and PCO₂, closing pressures (Pcrit), and awake lung volumes in different body positions. In 19/20 patients who slept with the device, RDI was significantly reduced with the nasal valve device compared to the diagnostic NPSG (27 ± 29/h vs 49 ± 28/h), with 50% of patients having an acceptable therapeutic response. Among demographic, lung volume, or diagnostic NPSG measures or markers of collapsibility, no significant predictors of therapeutic response were found. There was a suggestion that patients with position-dependent SDB (supine RDI > lateral RDI) were more likely to have an acceptable therapeutic response to the device. Successful elimination of SDB was associated with generation and maintenance of an elevated end expiratory pressure. No single definitive mechanism of action was elucidated. The present study shows that the nasal valve device can alter SDB across the full spectrum of SDB severity. There was a suggestion that subjects with positional or milder SDB in the lateral position were those most likely to respond.

  12. THE EFFECT OF SUBMAXIMAL INHALATION ON MEASURES DERIVED FROM FORCED EXPIRATORY SPIROMETRY

    Science.gov (United States)

    THE EFFECT OF SUBMAXIMAL INHALATION ON MEASURES DERIVED FROM FORCED EXPIRATORY SPIROMETRY. William F. McDonnell Human Studies Division, NHEERL, U.S. Environmental Protection Agency, RTP, NC 27711. Short-term exposure to ozone results in a neurally-mediated decrease in the ab...

  13. Changes in forced expiratory volume in 1 second over time in COPD

    DEFF Research Database (Denmark)

    Vestbo, Jørgen; Edwards, Lisa D; Scanlon, Paul D

    2011-01-01

    A key feature of chronic obstructive pulmonary disease (COPD) is an accelerated rate of decline in forced expiratory volume in 1 second (FEV(1)), but data on the variability and determinants of this change in patients who have established disease are scarce....

  14. A study of diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India

    Directory of Open Access Journals (Sweden)

    Jenny Jayapal

    2014-01-01

    Full Text Available Background: Peak Expiratory Flow Rate (PEFR reflects the strength and condition of respiratory muscles and the degree of airflow limitation in large airways. PEFR shows hour to hour variation that follows a specific pattern in asthmatics and healthy individuals. Adequate data is not available for the diurnal variation in normal individuals who are students in professional courses and had a sedentary life style. Hence, this study was undertaken to study the diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India. Materials and Methods: Peak expiratory flow rate was recorded in 50 adult healthy female students aged 18-23 years and studying in professional courses. Mini Wright′s peak flow meter was used to measure the peak expiratory flow rate. PEFR were recorded at 7-8 a.m., 10-11 a.m., 1-2 p.m., 4-5 p.m., and 7-8 p.m. for two consecutive days. Results: On analysis of PEFR records of individual subjects, it was seen that there was an overall dip in the morning at 7-8 h PEFR, which increased in the daytime, peaking in the afternoon at 1-2 p.m. and eventually decreased in the night. Subjects did not show the peak PEFR values at the same time point, 10% of subjects had a rise in PEFR in the early morning, afternoon (1-2 p.m. peak was observed in 48% subjects and evening (4-5 p.m. peak was observed in 16% subjects. 14% subjects showed a peak in the night time (7-8 p.m. PEFR values. Conclusion: This study provided the preliminary reference data of diurnal variation of peak expiratory flow rate in healthy adults. Since, there is a variation in the peak expiratory flow rate recorded during different time points of the day; hence, to compare the PEFR between individuals it is advisable to record the PEFR at the same time point.

  15. Physiological and morphological determinants of maximal expiratory flow in chronic obstructive lung disease

    NARCIS (Netherlands)

    H.A.W.M. Tiddens (Harm); J.M. Bogaard (Jan); J.C. de Jongste (Johan); W.C.J. Hop (Wim); H.O. Coxson (Harvey); P.D. Pare

    1996-01-01

    textabstractMaximal expiratory flow in chronic obstructive pulmonary disease (COPD) could be reduced by three different mechanisms; loss of lung elastic recoil, decreased airway conductance upstream of flow-limiting segments; and increased collapsibility of airways.

  16. Positive expiratory pressure therapy versus other airway clearance techniques for bronchiectasis.

    Science.gov (United States)

    Lee, Annemarie L; Burge, Angela T; Holland, Anne E

    2017-09-27

    People with bronchiectasis experience chronic cough and sputum production and require the prescription of airway clearance techniques (ACTs). A common type of ACT prescribed is positive expiratory pressure (PEP) therapy. A previous review has suggested that ACTs including PEP therapy are beneficial compared to no treatment in people with bronchiectasis. However, the efficacy of PEP therapy in a stable clinical state or during an acute exacerbation compared to other ACTs in bronchiectasis is unknown. The primary aim of this review was to determine the effects of PEP therapy compared with other ACTs on health-related quality of life (HRQOL), rate of acute exacerbations, and incidence of hospitalisation in individuals with stable or an acute exacerbation of bronchiectasis.Secondary aims included determining the effects of PEP therapy upon physiological outcomes and clinical signs and symptoms compared with other ACTs in individuals with stable or an acute exacerbation of bronchiectasis. We searched the Cochrane Airways Group Specialised Register of Trials, PEDro and clinical trials registries from inception to February 2017 and we handsearched relevant journals. Randomised controlled parallel and cross-over trials that compared PEP therapy versus other ACTs in participants with bronchiectasis. We used standard methodological procedures as outlined by Cochrane. Nine studies involving 213 participants met the inclusion criteria, of which seven were cross-over in design. All studies included adults with bronchiectasis, with eight including participants in a stable clinical state and one including participants experiencing an acute exacerbation. Eight studies used oscillatory PEP therapy, using either a Flutter or Acapella device and one study used Minimal PEP therapy. The comparison intervention differed between studies. The methodological quality of studies was poor, with cross-over studies including suboptimal or no washout period, and a lack of blinding of

  17. Development of position control of end-effector for CS-113 robot based on three degree of freedom motions

    International Nuclear Information System (INIS)

    Iqbal, Muhammad; Setiawan, Widi; Arif, Agus

    2003-01-01

    A software development for three degrees of freedom motions of CS-113 robot arm has been done. This software, which was based on inverse kinematic, can be used to control position of D and D (decontamination and Dismantlement) robot. A preliminary construction of robot arm (three degrees of freedom) has been constructed also to study the mechanic aspects. The scope of this research consist of direct kinematic and inverse kinematic implementation. The direct kinematic implementation developed according to following steps: (1) assigning kinematic parameters of CS-113 robot arm using Denavit-Hertenberg methods, (2) formulating kinematic equation for all joint. The inverse kinematic implementation developed by transforming position in Cartesian coordinates into joint angle in angle coordinates. Both direct and inverse kinematic were implemented with computer software which is written in the VISUAL BASIC. This software was tested on CS-113 robot. The theoretically calculation was done on MATLAB. Input of direct kinematic were joint angles (5 o , 10 o , -20 o , 15 o , 25 o , 30 o , -50 o , and 60 o ), whereas the input of inverse kinematic were the position on Cartesian coordinate, with the duration for moving end-effector testing 4 seconds. The test results of direct kinematic implementation on CS-113 robot were the position of end-effector on Cartesian coordinates. The position of end-effector which was measured experimentally on CS-113 robot compared with position of end-effector which was calculated on MATLAB. This comparison showed that static performance of CS-113 robot manipulator, bias (systematic error) that different from the end-effector position change within 8,9%, 12,3% and 27,3% on X, Y, Z axes, respectively, the measurements repeatability (precision) of end-effector position were ± 0,031 cm to ±0,183 cm. The test results of inverse kinematic implementation on CS-113 robot showed that the accuracy of end-effector position varied on all axes, the bias

  18. Effect of protective lung ventilation strategy combined with lung recruitment maneuver in patients with acute respiratory distress syndrome (ARDS

    Directory of Open Access Journals (Sweden)

    Sheng Yu

    2017-01-01

    Full Text Available Objective: To evaluate the efficacy and safety of protective lung ventilation strategy combined with lung recruitment maneuver (RM in the treatment patients with acute respiratory distress syndrome (ARDS.Methods: Totally 74 patients with ARDS admitted to the Department of Intensive Care Unit, Changshu Second People's Hospital in Jiangsu Province between September 2010 and June 2013 were selected and randomly divided into lung recruitment group and non-lung recruitment group, and the initial ventilation solution for both groups was synchronized intermittent mandatory ventilation (SIMV. For RM, SIMV mode (pressure control and pressure support was adopted. Positive end expiratory pressure (PEEP was increased by 5 cm H2O every time and maintained for 40-50 s before entering the next increasing period, and the peak airway pressure was kept below 45 cm H2O. After PEEP reached the maximum value, it was gradually reduced by 5 cm H2O every time and finally maintained at 15 cm H2O for 10 min.Results: A total of 74 patients with mean age of (49.0±18.6 years old were enrolled, 36 patients were enrolled in lung recruitment maneuver (RM group and 38 patients were enrolled into non-lung recruitment maneuver (non-RM group. 44 were male and accounted for 59.5% of all the patients. For the indicators such as PEEP, pressure support (PS, plateau airway pressure (Pplat, peak airway pressure (Ppeak, vital capacity (VC and fraction of inspired oxygen (FiO2, no statistical differences in the indicators were found between the RM group and non-RM group on D1, D3 and D7 (P>0.05, except that only FiO2 of RM group on D7 was significantly lower than that of non-RM group (47.2±10.0 vs. (52.2±10.5, P0.05. 28-day mortality, ICU mortality and in-hospital mortality were 25% vs. 28.9%, 25% vs. 26.3% and 36.1% vs. 39.5% respectively between RM group and non-RM group (all P>0.05.Conclusion: Protective lung ventilation strategy combined with lung recruitment maneuver can improve

  19. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Meijer, G. G.; Postma, D. S.; van der Heide, S.; de Reus, D. M.; Roorda, R. J.; Koëter, G. H.; van Aalderen, W. M.

    1996-01-01

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  20. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Postma, DS; VanderHeide, S; DeReus, DM; Koeter, GH; VanAalderen, WMC; Meijer, G.

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  1. Dead space and slope indices from the expiratory carbon dioxide tension-volume curve

    NARCIS (Netherlands)

    A.H. Kars (Alice); J.M. Bogaard (Jan); Th. Stijnen (Theo); J. de Vries; A.F.M. Verbraak (Anton); C. Hilvering

    1997-01-01

    textabstractThe slope of phase 3 and three noninvasively determined dead space estimates derived from the expiratory carbon dioxide tension (PCO2) versus volume curve, including the Bohr dead space (VD,Bohr), the Fowler dead space (VD,Fowler) and pre-interface expirate

  2. [Modification of expiratory peak flow (EPF) in 14 asthmatic subjects from Benin by short duration exercise training].

    Science.gov (United States)

    Lawani, M M; Hounkpatin, S; Akplogan, B

    2006-01-01

    Asthma is a world wide public health problem. It is the most commom chronic disease of school age children. Its severity is in constant increase. The frequency of the hospitalizations for asthma increased in practically all countries. Physical exercises and sport are used more and more as therapeutic means, in northern deveopped countries of where it was very early understood that it is necessary to integrate the asthmatic subjects into a program of specific physical training. This study undertaken in south saharian african country considers also assiduity in a physical training program as the factor of increase in the expiratory peak flow, of reinforcement of some principal muscles necessary to the improvement, and of the respiratory function of the asthmatic subject. Physical exercise is used as a non pharmacological therapy of asthma. This transversal study was carried out on fourteen asthmatic subjects of colleges in Porto-Novo's town, aged 15 years old to 25 years, of the two sexes. The results showed that: the Expiratory Peak Flow of Point (EPF) of the subjects at the beginning of the program is lower than the minimal average value of the group whatever the sex; the subjects average EPF increased from approximately 35% compared to the average at the beginning of the program; the subjects from family with asthmatic line, are much more inclined with respiratory embarrassments post-exercises than those who did not come from it; the respiratory embarrassments post-exercises noticed in the first weeks, grew blurred before the end of the program. This study suggests physical exercise adapted to the asthmatic subjects for the improvement of their health.

  3. Clinical factors affecting inspired gas humidification and oral dryness during noninvasive ventilation.

    Science.gov (United States)

    Oto, Jun; Imanaka, Hideaki; Nishimura, Masaji

    2011-10-01

    Oral dryness is a common complication during noninvasive ventilation (NIV). We measured the oral dryness of patients and performed a bench study to investigate factors related to humidification during NIV. Patients were randomly assigned into 2 groups: medium (Med group) and maximum (Max group) heated humidifier (HH) settings. Oral moistness was measured using an oral moisture-checking device, and the feeling of oral dryness was evaluated using a 0 to 10 numerical rating scale (NRS) at 0, 12, and 24 hours from the beginning of NIV and at 12 and 24 hours after NIV was discontinued. A bench study was performed to assess the effects of positive end-expiratory pressure (PEEP), the fraction of inspired oxygen (F(I)O(2)), and air leaks on absolute humidity. We evaluated 3 HH settings: no HH, HH at the medium setting, and HH at the maximum setting. The temperature in the outlet chamber was 31°C to 32°C for the medium HH setting and 38°C to 41°C for the maximum HH setting. In the clinical study, 12 patients were assigned to the Med group and 11 to the Max group. In the Med group, oral moistness decreased and NRS increased at 12 and 24 hours compared with 0 hours (P humidification and oral dryness during NIV. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Mild hypothermia attenuates changes in respiratory system mechanics and modifies cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation.

    Science.gov (United States)

    Dostál, P; Senkeřík, M; Pařízková, R; Bareš, D; Zivný, P; Zivná, H; Cerný, V

    2010-01-01

    Hypothermia was shown to attenuate ventilator-induced lung injury due to large tidal volumes. It is unclear if the protective effect of hypothermia is maintained under less injurious mechanical ventilation in animals without previous lung injury. Tracheostomized rats were randomly allocated to non-ventilated group (group C) or ventilated groups of normothermia (group N) and mild hypothermia (group H). After two hours of mechanical ventilation with inspiratory fraction of oxygen 1.0, respiratory rate 60 min(-1), tidal volume 10 ml x kg(-1), positive end-expiratory pressure (PEEP) 2 cm H2O or immediately after tracheostomy in non-ventilated animals inspiratory pressures were recorded, rats were sacrificed, pressure-volume (PV) curve of respiratory system constructed, bronchoalveolar lavage (BAL) fluid and aortic blood samples obtained. Group N animals exhibited a higher rise in peak inspiratory pressures in comparison to group H animals. Shift of the PV curve to right, higher total protein and interleukin-6 levels in BAL fluid were observed in normothermia animals in comparison with hypothermia animals and non-ventilated controls. Tumor necrosis factor-alpha was lower in the hypothermia group in comparison with normothermia and non-ventilated groups. Mild hypothermia attenuated changes in respiratory system mechanics and modified cytokine concentration in bronchoalveolar lavage fluid during low lung volume ventilation in animals without previous lung injury.

  5. Inspiratory and expiratory HRCT findings in Behcet's disease and correlation with pulmonary function tests

    Energy Technology Data Exchange (ETDEWEB)

    Oezer, Caner [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey)]. E-mail: cozer@mersin.edu.tr; Duce, Meltem Nass [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey); Ulubas, Bahar [Department of Respiratory Disease, Mersin University, Faculty of Medicine, Mersin (Turkey); Bicer, Ali [Department of Physical Medicine and Rehabilitation, Mersin University, Faculty of Medicine, Mersin (Turkey); Tuersen, Uemit [Department of Dermatology, Mersin University, Faculty of Medicine, Mersin (Turkey); Apaydin, F. Demir [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey); Yildiz, Altan [Department of Radiology, Mersin University, Faculty of Medicine, Mersin (Turkey); Camdeviren, Handan [Department of Biostatistics, Mersin University, Faculty of Medicine, Mersin (Turkey)

    2005-10-01

    Purpose: The purpose of our study was to describe the pulmonary parenchymal changes of Behcet's disease using high-resolution computed tomography and to correlate them with pulmonary function tests. Materials and methods: Thirty-four patients with Behcet's disease (18 men, 16 women), 3 of whom were symptomatic, were included as the study group. Four of 34 patients were smokers. Twenty asymptomatic volunteers (12 men, 8 women), 4 of whom were smokers, constituted the control group. The pulmonary function tests and high-resolution computed tomography were performed for both groups. Results: Inspiratory high-resolution computed tomography findings were abnormal in nine patients (26.5%) of the study group. In eight patients, there were multiple abnormalities, whereas one patient had only one abnormality. Pleural thickening and irregularities, major fissure thickening, emphysematous changes, bronchiectasis, parenchymal bands, and irregular densities, and parenchymal nodules were the encountered abnormalities. Inspiratory high-resolution computed tomography scans were normal in the control group. On expiratory scans, there was statistically significant difference between study group and control group when air trapping, especially grades 3 and 4, was compared (P < 0.01). Pulmonary function tests of both the study and the control groups were in normal ranges, and there was no statistically significant difference between the two groups according to pulmonary function tests (P > 0.05). Discussion and conclusion: High-resolution computed tomography is sensitive in the demonstration of pulmonary changes in patients with Behcet's disease. End-expiratory high-resolution computed tomography examination is very useful and necessary to show the presence of air trapping, thus the presence of small airway disease, even if the patient is asymptomatic or has normal pulmonary function tests.

  6. Peak expiratory flow variability, bronchial responsiveness, and susceptibility to ambient air pollution in adults

    NARCIS (Netherlands)

    Boezen, M; Schouten, Jan; Rijcken, B; Vonk, J; Gerritsen, J; Hoek, G; Brunekreef, B; Postma, D

    1998-01-01

    Bronchial hyperresponsiveness (BHR) and peak expiratory flow (PEF) variability are associated expressions of airway lability, yet probably reflect different underlying pathophysiologic mechanisms. We investigated whether both measures can be used interchangeably to identify subjects who are

  7. The Society for Translational Medicine: clinical practice guidelines for mechanical ventilation management for patients undergoing lobectomy

    Science.gov (United States)

    Zhang, Zhongheng; Brunelli, Alessandro; Chen, Chang; Chen, Chun; Chen, Gang; Chen, Haiquan; Chen, Jin-Shing; Cassivi, Stephen; Chai, Ying; Downs, John B.; Fang, Wentao; Fu, Xiangning; Garutti, Martínez I.; He, Jianxing; Hu, Jian; Huang, Yunchao; Jiang, Gening; Jiang, Hongjing; Jiang, Zhongmin; Li, Danqing; Li, Gaofeng; Li, Hui; Li, Qiang; Li, Xiaofei; Li, Yin; Li, Zhijun; Liu, Chia-Chuan; Liu, Deruo; Liu, Lunxu; Liu, Yongyi; Ma, Haitao; Mao, Weimin; Mao, Yousheng; Mou, Juwei; Ng, Calvin Sze Hang; Petersen, René H.; Qiao, Guibin; Rocco, Gaetano; Ruffini, Erico; Tan, Lijie; Tan, Qunyou; Tong, Tang; Wang, Haidong; Wang, Qun; Wang, Ruwen; Wang, Shumin; Xie, Deyao; Xue, Qi; Xue, Tao; Xu, Lin; Xu, Shidong; Xu, Songtao; Yan, Tiansheng; Yu, Fenglei; Yu, Zhentao; Zhang, Chunfang; Zhang, Lanjun; Zhang, Tao; Zhang, Xun; Zhao, Xiaojing; Zhao, Xuewei; Zhi, Xiuyi; Zhou, Qinghua

    2017-01-01

    Patients undergoing lobectomy are at significantly increased risk of lung injury. One-lung ventilation is the most commonly used technique to maintain ventilation and oxygenation during the operation. It is a challenge to choose an appropriate mechanical ventilation strategy to minimize the lung injury and other adverse clinical outcomes. In order to understand the available evidence, a systematic review was conducted including the following topics: (I) protective ventilation (PV); (II) mode of mechanical ventilation [e.g., volume controlled (VCV) versus pressure controlled (PCV)]; (III) use of therapeutic hypercapnia; (IV) use of alveolar recruitment (open-lung) strategy; (V) pre-and post-operative application of positive end expiratory pressure (PEEP); (VI) Inspired Oxygen concentration; (VII) Non-intubated thoracoscopic lobectomy; and (VIII) adjuvant pharmacologic options. The recommendations of class II are non-intubated thoracoscopic lobectomy may be an alternative to conventional one-lung ventilation in selected patients. The recommendations of class IIa are: (I) Therapeutic hypercapnia to maintain a partial pressure of carbon dioxide at 50–70 mmHg is reasonable for patients undergoing pulmonary lobectomy with one-lung ventilation; (II) PV with a tidal volume of 6 mL/kg and PEEP of 5 cmH2O are reasonable methods, based on current evidence; (III) alveolar recruitment [open lung ventilation (OLV)] may be beneficial in patients undergoing lobectomy with one-lung ventilation; (IV) PCV is recommended over VCV for patients undergoing lung resection; (V) pre- and post-operative CPAP can improve short-term oxygenation in patients undergoing lobectomy with one-lung ventilation; (VI) controlled mechanical ventilation with I:E ratio of 1:1 is reasonable in patients undergoing one-lung ventilation; (VII) use of lowest inspired oxygen concentration to maintain satisfactory arterial oxygen saturation is reasonable based on physiologic principles; (VIII) Adjuvant drugs

  8. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants—the impact of ventilator settings on tracheal pressure swings

    International Nuclear Information System (INIS)

    Hentschel, Roland; Buntzel, Julia; Guttmann, Josef; Schumann, Stefan

    2011-01-01

    Resistive properties of endotracheal tubes (ETTs) are particularly relevant in newborns and small infants who are generally ventilated through ETTs with a small inner diameter. The ventilation rate is also high and the inspiratory time (ti) is short. These conditions effectuate high airway flows with excessive flow acceleration, so airway resistance and inertance play an important role. We carried out a model study to investigate the impact of varying ETT size, lung compliance and ventilator settings, such as peak inspiratory pressure (PIP), positive end expiratory pressure (PEEP) and inspiratory time (ti) on the pressure–flow characteristics with respect to the resistive and inertive properties of the ETT. Pressure at the Y piece was compared to direct measurement of intratracheal pressure (P trach ) at the tip of the ETT, and pressure drop (ΔP ETT ) was calculated. Applying published tube coefficients (Rohrer's constants and inertance), P trach was calculated from ventilator readings and compared to measured P trach using the root-mean-square error. The most relevant for ΔP ETT was the ETT size, followed by (in descending order) PIP, compliance, ti and PEEP, with gas flow velocity being the principle in common for all these parameters. Depending on the ventilator settings ΔP ETT exceeded 8 mbar in the smallest 2.0 mm ETT. Consideration of inertance as an additional effect in this setting yielded a better agreement of calculated versus measured P trach than Rohrer's constants alone. We speculate that exact tracheal pressure tracings calculated from ventilator readings by applying Rohrer's equation and the inertance determination to small size ETTs would be helpful. As an integral part of ventilator software this would (1) allow an estimate of work of breathing and implementation of an automatic tube compensation, and (2) be important for gentle ventilation in respiratory care, especially of small infants, since it enables the physician to

  9. Early detection of ventilation-induced brain injury using magnetic resonance spectroscopy and diffusion tensor imaging: an in vivo study in preterm lambs.

    Directory of Open Access Journals (Sweden)

    Béatrice Skiöld

    Full Text Available BACKGROUND AND AIM: High tidal volume (VT ventilation during resuscitation of preterm lambs results in brain injury evident histologically within hours after birth. We aimed to investigate whether magnetic resonance spectroscopy (MRS and/or diffusion tensor imaging (DTI can be used for early in vivo detection of ventilation-induced brain injury in preterm lambs. METHODS: Newborn lambs (0.85 gestation were stabilized with a "protective ventilation" strategy (PROT, n = 7: prophylactic Curosurf, sustained inflation, VT 7 mL/kg, positive end expiratory pressure (PEEP 5 cmH2O or an initial 15 minutes of "injurious ventilation" (INJ, n = 10: VT 12 mL/kg, no PEEP, late Curosurf followed by PROT ventilation for the remainder of the experiment. At 1 hour, lambs underwent structural magnetic resonance imaging (Siemens, 3 Tesla. For measures of mean/axial/radial diffusivity (MD, AD, RD and fractional anisotropy (FA, 30 direction DTI was performed. Regions of interests encompassed the thalamus, internal capsule, periventricular white matter and the cerebellar vermis. MRS was performed using a localized single-voxel (15×15×20 mm3, echo time 270 ms encompassing suptratentorial deep nuclear grey matter and central white matter. Peak-area ratios for lactate (Lac relative to N-acetylaspartate (NAA, choline (Cho and creatine (Cr were calculated. Groups were compared using 2-way RM-ANOVA, Mann-Whitney U-test and Spearman's correlations. RESULTS: No cerebral injury was seen on structural MR images. Lambs in the INJ group had higher mean FA and lower mean RD in the thalamus compared to PROT lambs, but not in the other regions of interest. Peak-area lactate ratios >1.0 was only seen in INJ lambs. A trend of higher mean peak-area ratios for Lac/Cr and Lac/Cho was seen, which correlated with lower pH in both groups. CONCLUSION: Acute changes in brain diffusion measures and metabolite peak-area ratios were observed after injurious ventilation. Early MRS/DTI is

  10. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?

    Science.gov (United States)

    Tracy, Mark Brian; Priyadarshi, Archana; Goel, Dimple; Lowe, Krista; Huvanandana, Jacqueline; Hinder, Murray

    2018-05-01

    International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH 2 O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5-65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH 2 O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3-22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH 2 O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6-2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. This study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Time Course of Changes in Extravascular Water of the Lung After Pneumonectomy According to the Data of Transpulmonal Thermodilution

    Directory of Open Access Journals (Sweden)

    V. V. Kuzkov

    2006-01-01

    Full Text Available Objective: to study the accuracy of pulmonary extravascular water (PEVW measurement by thermochromodilution (TCD and isolated thermodilution (ITD on a model of pneumonectomy and subsequent ventilator-induced lung lesion (VILL in sheep.Materials and methods: the study was conducted at the Research Laboratory of University of Tromse. The experiment included 12 sheep weighing 35.6±4.6 kg. Thoracotomy and right-sided pneumonectomy were performed in the animals under general anesthesia and controlled artificial ventilation. After measurement of the parameters of systemic hemodynamics and PEVW, the animals were divided into 2 groups: 1 1 those undergoing protective ventilation (PV, n=6 with a tidal volume (TV of 6 ml/kg and a positive end-expiratory pressure (PEEP of 2 cm H2O and 2 those with VILL (n=6 with a TV of 12 ml/kg and a PEEP of 0 cm H2O. TCD and ITD (Cold Z-021 and PiCCOplus monitors, respectively (Pulsion, Germany were used to measure volumetric parameters and PEVW. The parameters of pulmonary hemodynamics, respiratory mechanics, and blood gas composition were recorded. After euthanasia of the animals, their lungs were taken to determine the control value of PEVW by postmortem gravimetry (PG.Results: in the VILL group, significant pulmonary alveolar edema developed, which was followed by hyperthermia, elevated pulmonary pressure, and increased intrapulmonary shunting. Analysis of the data indicated a close correlation between the PEVW values obtained by TCD and ITD with PG (r=0.95 and r=0.81, respectively; p<0.01; n=12. The PG deviation was 0.57±2.05 and 2.68±3.61 ml/kg for TCD and ITD, respectively (M±2d, p<0.05.Conclusion: both used techniques have an acceptable accuracy and adequately reflect both a reduction in PEVW after pneumectomy and its increase in the presence of VILL. Volumotrauma may be the key factor that provokes the development of postpneumectomic edema of the lung. 

  12. Seasonal variations in house dust mite influence the circadian peak expiratory flow amplitude

    NARCIS (Netherlands)

    Postma, DS; vanderHeide, S; deReus, DM; Koeter, GH; vanAalderen, WMC; Meijer, G.

    1996-01-01

    The aim of the study was to investigate whether seasonal differences in house dust mite (HDM) allergen exposure influence the circadian peak expiratory flow (PEF) amplitude in asthmatic children. Asthmatic children (n = 25) with a solitary allergy to HDM were studied in spring and in autumn. All

  13. Expiratory flow limitation and operating lung volumes during exercise in older and younger adults.

    Science.gov (United States)

    Smith, Joshua R; Kurti, Stephanie P; Meskimen, Kayla; Harms, Craig A

    2017-06-01

    We determined the effect of aging on expiratory flow limitation (EFL) and operating lung volumes when matched for lung size. We hypothesized that older adults will exhibit greater EFL and increases in EELV during exercise compared to younger controls. Ten older (5M/5W; >60years old) and nineteen height-matched young adults (10M/9W) were recruited. Young adults were matched for%predicted forced vital capacity (FVC) (Y-matched%Pred FVC; n=10) and absolute FVC (Y-matched FVC; n=10). Tidal flow-volume loops were recorded during the incremental exercise test with maximal flow-volume loops measured pre- and post-exercise. Compared to younger controls, older adults exhibited more EFL at ventilations of 26, 35, 51, and 80L/min. The older group had higher end-inspiratory lung volume compared to Y-matched%Pred FVC group during submaximal ventilations. The older group increased EELV during exercise, while EELV stayed below resting in the Y-matched%Pred FVC group. These data suggest older adults exhibit more EFL and increase EELV earlier during exercise compared to younger adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Gravity predominates over ventilatory pattern in the prevention of ventilator-associated pneumonia.

    Science.gov (United States)

    Li Bassi, Gianluigi; Marti, Joan Daniel; Saucedo, Lina; Rigol, Montserrat; Roca, Ignasi; Cabanas, Maria; Muñoz, Laura; Ranzani, Otavio Tavares; Giunta, Valeria; Luque, Nestor; Esperatti, Mariano; Gabarrus, Albert; Fernandez, Laia; Rinaudo, Mariano; Ferrer, Miguel; Ramirez, Jose; Vila, Jordi; Torres, Antoni

    2014-09-01

    In the semirecumbent position, gravity-dependent dissemination of pathogens has been implicated in the pathogenesis of ventilator-associated pneumonia. We compared the preventive effects of a ventilatory strategy, aimed at decreasing pulmonary aspiration and enhancing mucus clearance versus the Trendelenburg position. Prospective randomized animal study. Animal research facility, University of Barcelona, Spain. Twenty-four Large White-Landrace pigs. Pigs were intubated and on mechanical ventilation for 72 hours. Following surgical preparation, pigs were randomized to be positioned: 1) in semirecumbent/prone position, ventilated with a duty cycle (TITTOT) of 0.33 and without positive end-expiratory pressure (control); 2) as in the control group, positive end-expiratory pressure of 5 cm H2O and TITTOT to achieve a mean expiratory-inspiratory flow bias of 10 L/min (treatment); 3) in Trendelenburg/prone position and ventilated as in the control group (Trendelenburg). Following randomization, Pseudomonas aeruginosa was instilled into the oropharynx. Mucus clearance rate was measured through fluoroscopic tracking of tracheal markers. Microspheres were instilled into the subglottic trachea to assess pulmonary aspiration. Ventilator-associated pneumonia was confirmed by histological/microbiological studies. The mean expiratory-inspiratory flow in the treatment, control, and Trendelenburg groups were 10.7 ± 1.7, 1.8 ± 3.7 and 4.3 ± 2.8 L/min, respectively (p gravity-dependent translocation of oropharyngeal pathogens and development of ventilator-associated pneumonia. These findings further substantiate the primary role of gravity in the pathogenesis of ventilator-associated pneumonia.

  15. American Society for Pain Management Nursing position statement: pain management at the end of life.

    Science.gov (United States)

    Reynolds, Janice; Drew, Debra; Dunwoody, Colleen

    2013-09-01

    Pain at the end of life continues to be of great concern as it may be unrecognized or untreated. While nurses have an ethical obligation to reduce suffering at the end of life, barriers remain regarding appropriate and adequate pain management at the end of life. This position statement from the American Society for Pain Management Nursing contains recommendations for nurses, prescribers, and institutions that would improve pain management for this vulnerable population. Copyright © 2013 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  16. Individualised perioperative open-lung approach versus standard protective ventilation in abdominal surgery (iPROVE): a randomised controlled trial.

    Science.gov (United States)

    Ferrando, Carlos; Soro, Marina; Unzueta, Carmen; Suarez-Sipmann, Fernando; Canet, Jaume; Librero, Julián; Pozo, Natividad; Peiró, Salvador; Llombart, Alicia; León, Irene; India, Inmaculada; Aldecoa, Cesar; Díaz-Cambronero, Oscar; Pestaña, David; Redondo, Francisco J; Garutti, Ignacio; Balust, Jaume; García, Jose I; Ibáñez, Maite; Granell, Manuel; Rodríguez, Aurelio; Gallego, Lucía; de la Matta, Manuel; Gonzalez, Rafael; Brunelli, Andrea; García, Javier; Rovira, Lucas; Barrios, Francisco; Torres, Vicente; Hernández, Samuel; Gracia, Estefanía; Giné, Marta; García, María; García, Nuria; Miguel, Lisset; Sánchez, Sergio; Piñeiro, Patricia; Pujol, Roger; García-Del-Valle, Santiago; Valdivia, José; Hernández, María J; Padrón, Oto; Colás, Ana; Puig, Jaume; Azparren, Gonzalo; Tusman, Gerardo; Villar, Jesús; Belda, Javier

    2018-03-01

    The effects of individualised perioperative lung-protective ventilation (based on the open-lung approach [OLA]) on postoperative complications is unknown. We aimed to investigate the effects of intraoperative and postoperative ventilatory management in patients scheduled for abdominal surgery, compared with standard protective ventilation. We did this prospective, multicentre, randomised controlled trial in 21 teaching hospitals in Spain. We enrolled patients who were aged 18 years or older, were scheduled to have abdominal surgery with an expected time of longer than 2 h, had intermediate-to-high-risk of developing postoperative pulmonary complications, and who had a body-mass index less than 35 kg/m 2 . Patients were randomly assigned (1:1:1:1) online to receive one of four lung-protective ventilation strategies using low tidal volume plus positive end-expiratory pressure (PEEP): open-lung approach (OLA)-iCPAP (individualised intraoperative ventilation [individualised PEEP after a lung recruitment manoeuvre] plus individualised postoperative continuous positive airway pressure [CPAP]), OLA-CPAP (intraoperative individualised ventilation plus postoperative CPAP), STD-CPAP (standard intraoperative ventilation plus postoperative CPAP), or STD-O 2 (standard intraoperative ventilation plus standard postoperative oxygen therapy). Patients were masked to treatment allocation. Investigators were not masked in the operating and postoperative rooms; after 24 h, data were given to a second investigator who was masked to allocations. The primary outcome was a composite of pulmonary and systemic complications during the first 7 postoperative days. We did the primary analysis using the modified intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT02158923. Between Jan 2, 2015, and May 18, 2016, we enrolled 1012 eligible patients. Data were available for 967 patients, whom we included in the final analysis. Risk of pulmonary and systemic

  17. Effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by parkinson?s disease

    OpenAIRE

    Byeon, Haewon

    2016-01-01

    [Purpose] This study aimed to investigate the effect of simultaneous application of postural techniques and expiratory muscle strength training on the enhancement of the swallowing function of patients with dysphagia caused by Parkinson?s disease. [Subjects and Methods] The subjects of this study were 18 patients who received simultaneous application of postural techniques and expiratory muscle strength training and 15 patients who received expiratory muscle strength training only. Postural t...

  18. Utilization of the lower inflection point of the pressure-volume curve results in protective conventional ventilation comparable to high frequency oscillatory ventilation in an animal model of acute respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    Felipe S. Rossi

    2008-01-01

    Full Text Available INTRODUCTION: Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE: To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume curve as the determinant of positive end-expiratory pressure to obtain similar levels of recruitment and alveolar stability. METHODS: After lung lavage of adult rabbits and lower inflection point determination, two groups were randomized: conventional (positive end-expiratory pressure = lower inflection point; tidal volume=6 ml/kg and high frequency ventilation (mean airway pressures= lower inflection point +4 cmH2O. Blood gas and hemodynamic data were recorded over 4 h. After sacrifice, protein analysis from lung lavage and histologic evaluation were performed. RESULTS: The oxygenation parameters, protein and histological data were similar, except for the fact that significantly more normal alveoli were observed upon protective ventilation. High frequency ventilation led to lower PaCO2 levels. DISCUSSION: Determination of the lower inflection point of the pressure-volume curve is important for setting the minimum end expiratory pressure needed to keep the airways opened. This is useful when comparing different strategies to treat severe respiratory insufficiency, optimizing conventional ventilation, improving oxygenation and reducing lung injury. CONCLUSIONS: Utilization of the lower inflection point of the pressure-volume curve in the ventilation strategies considered in this study resulted in comparable efficacy with regards to oxygenation and hemodynamics, a high PaCO2 level and a lower pH. In addition, a greater number of normal alveoli were found after protective conventional ventilation in an animal model of acute respiratory distress syndrome.

  19. Segmentation of expiratory and inspiratory sounds in baby cry audio recordings using hidden Markov models.

    Science.gov (United States)

    Aucouturier, Jean-Julien; Nonaka, Yulri; Katahira, Kentaro; Okanoya, Kazuo

    2011-11-01

    The paper describes an application of machine learning techniques to identify expiratory and inspiration phases from the audio recording of human baby cries. Crying episodes were recorded from 14 infants, spanning four vocalization contexts in their first 12 months of age; recordings from three individuals were annotated manually to identify expiratory and inspiratory sounds and used as training examples to segment automatically the recordings of the other 11 individuals. The proposed algorithm uses a hidden Markov model architecture, in which state likelihoods are estimated either with Gaussian mixture models or by converting the classification decisions of a support vector machine. The algorithm yields up to 95% classification precision (86% average), and its ability generalizes over different babies, different ages, and vocalization contexts. The technique offers an opportunity to quantify expiration duration, count the crying rate, and other time-related characteristics of baby crying for screening, diagnosis, and research purposes over large populations of infants.

  20. Mechanical ventilation in abdominal surgery.

    Science.gov (United States)

    Futier, E; Godet, T; Millot, A; Constantin, J-M; Jaber, S

    2014-01-01

    One of the key challenges in perioperative care is to reduce postoperative morbidity and mortality. Patients who develop postoperative morbidity but survive to leave hospital have often reduced functional independence and long-term survival. Mechanical ventilation provides a specific example that may help us to shift thinking from treatment to prevention of postoperative complications. Mechanical ventilation in patients undergoing surgery has long been considered only as a modality to ensure gas exchange while allowing maintenance of anesthesia with delivery of inhaled anesthetics. Evidence is accumulating, however, suggesting an association between intraoperative mechanical ventilation strategy and postoperative pulmonary function and clinical outcome in patients undergoing abdominal surgery. Non-protective ventilator settings, especially high tidal volume (VT) (>10-12mL/kg) and the use of very low level of positive end-expiratory pressure (PEEP) (PEEPventilator-associated lung injury in patients with healthy lungs. Stimulated by previous findings in patients with acute respiratory distress syndrome, the use of lower tidal volume ventilation is becoming increasingly more common in the operating room. However, lowering tidal volume, though important, is only part of the overall multifaceted approach of lung protective mechanical ventilation. In this review, we aimed at providing the most recent and relevant clinical evidence regarding the use of mechanical ventilation in patients undergoing abdominal surgery. Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  1. Fas-deficient mice have impaired alveolar neutrophil recruitment and decreased expression of anti-KC autoantibody:KC complexes in a model of acute lung injury

    Directory of Open Access Journals (Sweden)

    Gil Sucheol

    2012-10-01

    Full Text Available Abstract Background Exposure to mechanical ventilation enhances lung injury in response to various stimuli, such as bacterial endotoxin (LPS. The Fas/FasL system is a receptor ligand system that has dual pro-apoptotic and pro-inflammatory functions and has been implicated in the pathogenesis of lung injury. In this study we test the hypothesis that a functioning Fas/FasL system is required for the development of lung injury in mechanically ventilated mice. Methods C57BL/6 (B6 and Fas-deficient lpr mice were exposed to either intra-tracheal PBS followed by spontaneous breathing or intra-tracheal LPS followed by four hours mechanical ventilation with tidal volumes of 10 mL/kg, respiratory rate of 150 breaths per minute, inspired oxygen 0.21 and positive end expiratory pressure (PEEP of 3 cm of water. Results Compared with the B6 mice, the lpr mice showed attenuation of the neutrophilic response as measured by decreased numbers of BAL neutrophils and lung myeloperoxidase activity. Interestingly, the B6 and lpr mice had similar concentrations of pro-inflammatory cytokines, including CXCL1 (KC, and similar measurements of permeability and apoptosis. However, the B6 mice showed greater deposition of anti-KC:KC immune complexes in the lungs, as compared with the lpr mice. Conclusions We conclude that a functioning Fas/FasL system is required for full neutrophilic response to LPS in mechanically ventilated mice.

  2. Ventilation distribution measured with EIT at varying levels of pressure support and Neurally Adjusted Ventilatory Assist in patients with ALI.

    Science.gov (United States)

    Blankman, Paul; Hasan, Djo; van Mourik, Martijn S; Gommers, Diederik

    2013-06-01

    The purpose of this study was to compare the effect of varying levels of assist during pressure support (PSV) and Neurally Adjusted Ventilatory Assist (NAVA) on the aeration of the dependent and non-dependent lung regions by means of Electrical Impedance Tomography (EIT). We studied ten mechanically ventilated patients with Acute Lung Injury (ALI). Positive-End Expiratory Pressure (PEEP) and PSV levels were both 10 cm H₂O during the initial PSV step. Thereafter, we changed the inspiratory pressure to 15 and 5 cm H₂O during PSV. The electrical activity of the diaphragm (EAdi) during pressure support ten was used to define the initial NAVA gain (100 %). Thereafter, we changed NAVA gain to 150 and 50 %, respectively. After each step the assist level was switched back to PSV 10 cm H₂O or NAVA 100 % to get a new baseline. The EIT registration was performed continuously. Tidal impedance variation significantly decreased during descending PSV levels within patients, whereas not during NAVA. The dorsal-to-ventral impedance distribution, expressed according to the center of gravity index, was lower during PSV compared to NAVA. Ventilation contribution of the dependent lung region was equally in balance with the non-dependent lung region during PSV 5 cm H₂O, NAVA 50 and 100 %. Neurally Adjusted Ventilatory Assist ventilation had a beneficial effect on the ventilation of the dependent lung region and showed less over-assistance compared to PSV in patients with ALI.

  3. Non-pharmacological strategies for blood conservation in cardiac surgery.

    Science.gov (United States)

    Ruel, M A; Rubens, F D

    2001-04-01

    Of all surgical specialties, cardiac operations are most often associated with coagulopathy, blood loss, and the need for transfusions. This not only represents a major burden on blood procurement and banking organizations at all levels, but also constitutes a risk for each patient receiving allogeneic blood products. This paper reviews current non-pharmacological strategies aimed at decreasing blood use in patients undergoing cardiac surgery. The literature pertaining to each blood conservation strategy was searched, reviewed, and appraised. Meta- analyses were also consulted and their results complemented with subsequent reports when available. Preoperative autologous donation programs are effective in decreasing allogeneic transfusions, but are costly and applicable to elective patients only. Off-pump revascularization strategies also appear to decrease transfusion requirements in suitable patients. The effectiveness of acute normovolemic hemodilution, retrograde autologous priming, small volume cardiopulmonary bypass circuits, platelet-rich plasmapheresis, alternative heparin strategies, and postoperative cell salvage are more difficult to appraise as a high proportion of available studies suffer from lack of transfusion guidelines or the absence of blinding. Biological glues, surgical adhesives, and postoperative increases in positive end-expiratory pressure (PEEP) have no demonstrated efficacy. The applicability or effectiveness of many of these modalities remains controversial and more studies are needed before they may be employed routinely in cardiac surgical patients. The judicious use of rational transfusion guidelines may still be the simplest and most cost-effective means of blood conservation today.

  4. Severe bronchopulmonary dysplasia improved by noninvasive positive pressure ventilation: a case report

    Directory of Open Access Journals (Sweden)

    Mann Christian

    2011-09-01

    Full Text Available Abstract Introduction This is the first report to describe the feasibility and effectiveness of noninvasive positive pressure ventilation in the secondary treatment of bronchopulmonary dysplasia. Case presentation A former male preterm of Caucasian ethnicity delivered at 29 weeks gestation developed severe bronchopulmonary dysplasia. At the age of six months he was in permanent tachypnea and dyspnea and in need of 100% oxygen with a flow of 2.0 L/minute via a nasal cannula. Intermittent nocturnal noninvasive positive pressure ventilation was then administered for seven hours daily. The ventilator was set at a positive end-expiratory pressure of 6 cmH2O, with pressure support of 4 cmH2O, trigger at 1.4 mL/second, and a maximum inspiratory time of 0.7 seconds. Over the course of seven weeks, the patient's maximum daytime fraction of inspired oxygen via nasal cannula decreased from 1.0 to 0.75, his respiratory rate from 64 breaths/minute to 50 breaths/minute and carbon dioxide from 58 mmHg to 44 mmHg. Conclusion Noninvasive positive pressure ventilation may be a novel therapeutic option for established severe bronchopulmonary dysplasia. In the case presented, noninvasive positive pressure ventilation achieved sustained improvement in ventilation and thus prepared our patient for safe home oxygen therapy.

  5. Rail-guided robotic end-effector position error due to rail compliance and ship motion

    NARCIS (Netherlands)

    Borgerink, Dian; Stegenga, J.; Brouwer, Dannis Michel; Woertche, H.J.; Stramigioli, Stefano

    2014-01-01

    A rail-guided robotic system is currently being designed for the inspection of ballast water tanks in ships. This robotic system will manipulate sensors toward the interior walls of the tank. In this paper, the influence of rail compliance on the end-effector position error due to ship movement is

  6. Difficulty in obtaining peak expiratory flow measurements in children with acute asthma.

    Science.gov (United States)

    Gorelick, Marc H; Stevens, Molly W; Schultz, Theresa; Scribano, Philip V

    2004-01-01

    To determine the frequency with which children >or=6 years with acute asthma can perform peak expiratory flow rate measurements (PEFR) in an emergency department (ED). Data were obtained from a prospective cohort study of children with acute asthma. All children (age 2-18 years old) treated in an urban pediatric ED for an acute exacerbation during randomly selected days over a 12-month period were prospectively evaluated. According to treatment protocols, PEFR was to be measured in all children age 6 years and older before therapy and after each treatment with inhaled bronchodilators. Registered respiratory therapists obtained PEFR and evaluated whether patients were able to perform the maneuver adequately. Four hundred and fifty-six children, 6 to 18 years old (median 10 years), were enrolled; 291 (64%) had PEFR measured at least once. Of those in whom PEFR was attempted at least once, only 190 (65%) were able to perform adequately. At the start of therapy, 54% (142/262) were able to perform PEFR. Of the 120 who were unable to perform initially, 76 had another attempt at the end of the ED treatment, and 55 (72%) were still unable to perform. A total of 149 patients had attempts at PEFR both at the start and end of treatment, of these, only 71 (48%) provided valid information on both attempts. Patients unable to perform PEFR were younger (mean +/- SD = 8.7 +/- 2.8 years) than those who were able to perform successfully (11.2 +/- 3.2 years) and those with no attempts (10.0 +/- 3.4 years). Children admitted to the hospital were more likely to be unable to perform PEFR (58/126 = 46%) than those discharged from the ED (43/330 = 13%, P < 0.0001). Adequate PEFR measurements are difficult to obtain in children with acute asthma. Treatment and research protocols cannot rely exclusively on PEFR for evaluation of severity.

  7. Effects of pleural effusion drainage on oxygenation, respiratory mechanics, and hemodynamics in mechanically ventilated patients.

    Science.gov (United States)

    Razazi, Keyvan; Thille, Arnaud W; Carteaux, Guillaume; Beji, Olfa; Brun-Buisson, Christian; Brochard, Laurent; Mekontso Dessap, Armand

    2014-09-01

    In mechanically ventilated patients, the effect of draining pleural effusion on oxygenation is controversial. We investigated the effect of large pleural effusion drainage on oxygenation, respiratory function (including lung volumes), and hemodynamics in mechanically ventilated patients after ultrasound-guided drainage. Arterial blood gases, respiratory mechanics (airway, pleural and transpulmonary pressures, end-expiratory lung volume, respiratory system compliance and resistance), and hemodynamics (blood pressure, heart rate, and cardiac output) were recorded before and at 3 and 24 hours (H24) after pleural drainage. The respiratory settings were kept identical during the study period. The mean volume of effusion drained was 1,579 ± 684 ml at H24. Uncomplicated pneumothorax occurred in two patients. Respiratory mechanics significantly improved after drainage, with a decrease in plateau pressure and a large increase in end-expiratory transpulmonary pressure. Respiratory system compliance, end-expiratory lung volume, and PaO2/FiO2 ratio all improved. Hemodynamics were not influenced by drainage. Improvement in the PaO2/FiO2 ratio from baseline to H24 was positively correlated with the increase in end-expiratory lung volume during the same time frame (r = 0.52, P = 0.033), but not with drained volume. A high value of pleural pressure or a highly negative transpulmonary pressure at baseline predicted limited lung expansion following effusion drainage. A lesser improvement in oxygenation occurred in patients with ARDS. Drainage of large (≥500 ml) pleural effusion in mechanically ventilated patients improves oxygenation and end-expiratory lung volume. Oxygenation improvement correlated with an increase in lung volume and a decrease in transpulmonary pressure, but was less so in patients with ARDS.

  8. Dead space and slope indices from the expiratory carbon dioxide tension-volume curve

    OpenAIRE

    Kars, Alice; Bogaard, Jan; Stijnen, Theo; Vries, J.; Verbraak, Anton; Hilvering, C.

    1997-01-01

    textabstractThe slope of phase 3 and three noninvasively determined dead space estimates derived from the expiratory carbon dioxide tension (PCO2) versus volume curve, including the Bohr dead space (VD,Bohr), the Fowler dead space (VD,Fowler) and pre-interface expirate (PIE), were investigated in 28 healthy control subjects, 12 asthma and 29 emphysema patients (20 severely obstructed and nine moderately obstructed) with the aim to establish diagnostic value. Because breath volume and frequenc...

  9. Successful conservative management of a rare complication of tracheostomy; extensive posterior tracheal false pouch.

    Science.gov (United States)

    Ha, Jennifer F; Ostwani, Waseem; Green, Glenn

    2016-11-01

    With the advent of improved neonatal and pediatric intensive care management, tracheostomy is increasingly performed in children requiring prolonged ventilation. Even though tracheostomy is generally a safe procedure, there remains mortality and morbidity associated with it. We report a rare complication of a tracheostomy tube resulting in extensive erosion and posterior tracheal false pouch secondary to a large tracheostomy tube and high positive end expiratory pressure in a 12-month-old infant. This was managed successfully with conservative treatment. A former 34-week premature infant was transferred to our pediatrics intensive care unit (PICU) with recurrent episodes of cardiopulmonary arrests due to suspected severe tracheobronchomalacia. The patient has bronchopulomonary dysplasia, severe restrictive lung disease and thoracic insufficiency from skeletal dysplasia requiring tracheostomy tube (TT) at two-month-old and mechanical ventilation. The 3.5 NEO TT was gradually upsized to a 5. The PEEP setting at transfer was 18cmH2O. The direct laryngoscopy and bronchoscopy showed moderate tracheomalacia at the innominate artery with a false pouch in the posterior tracheal wall that was 1.1cm below the tracheostomy stoma. A multi-disciplinary discussion including otolaryngology, PICU, Pulmonary Medicine, and Pediatric Surgery decided on conservative management. The false pouch healed and she was transferred back to referring PICU after a 46-day. Tracheal wall erosion resulting in a pouch formation is a rare complication, but it should be considered in patients with long term tracheostomy with difficulty ventilation and oxygenation with positional change. DLB is a useful tool in its diagnosis and conservative management can be successful. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. The correlation between the paired inspiratory and expiratory three-dimensional quantitative CT and pulmonary function test in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Sui Xi; Song Wei; Xue Huadan; Song Lan; Yang Liang; Jin Zhengyu

    2013-01-01

    Objective: To investigate the correlation between the paired inspiratory and expiratory quantitative CT and pulmonary function tests (PFTs) in patients with chronic obstructive pulmonary disease (COPD). Methods: A total of 84 patients with COPD were enrolled. For each patient, CT scan was performed in deep inspiration and expiration. Using automatic post-processing software, a three-dimension quantitative measurement was employed to assess the CT parameters of emphysema and air trapping. The correlation between CT and PFT was evaluated by the Spearman rank correlation test and multivariate linear regression analysis. Results: The percent 1 [Perc_1, (-984.28 ± 17.93) HU] and percent 15 [Perc_1_5, (-948.35 ± 22.26) HU] from the CT parameters of emphysema were positively correlated with the forced expiratory volume in 1 second predicted (FEV_1%, 48.69 ± 23, 47), the ratio of forced expiratory volume in 1 second over forced vital capacity [FEV_1/FVC, (45.89 ± 15.36)%, r = 0.45-0.67, P < 0.01], was negatively correlated with the ratio of residual volume to total lung capacity [RV/TLC, (61.32 ± 14.48)%]. The other CT parameters of emphysema index (EI) and the parameters of air trapping, the change in relative lung volume with attenuation values from -860 to -950 HU [RVC_-_8_6_0_-_-_9_5_0, (17.66 ± 22.36)%], the expiration to inspiration ratio of mean lung density (MLD_e_x_/_i_n, 0.93 ± 0.06), the expiration to inspiration ratio of lung volume (LV_e_x_/_i_n, 0.71 ± 0.14) had negative correlations with logFEV_1%, FEV_1/FVC (r = -0.48--0.69, P < 0.01) and positive correlations with RV/TLC (r = 0.41-0.66, P < 0.01). The further univariate linear regressions showed that EI, Perc_1, Pere_1_5, RVC_-_8_6_0_-_-_9_5_0, MLD_e_x_/_i_n, LV_e_x_/_i_n were correlated with the parameters of PFTs (R square values of the regression equation, ranged from 0.27 to 0.66, P < 0.01). After the pairwise combinations of the parameters of emphysema and air trapping, multivariate stepwise

  11. TU-CD-BRA-11: Application of Bone Suppression Technique to Inspiratory/expiratory Chest Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, R; Sanada, S [Kanazawa University, Kanazawa, Ishikawa (Japan); Sakuta, K; Kawashima, H [Kanazawa University Hospital, Kanazawa, Ishikawa (Japan); Kishitani, Y [TOYO Corporation, Chuoh-ku, Tokyo (Japan)

    2015-06-15

    Purpose: The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images normally obtained by the dual-energy subtraction technique. This study was performed to investigate the usefulness of bone suppression technique in quantitative analysis of pulmonary function in inspiratory/expiratory chest radiography. Methods: Commercial bone suppression image processing software (ClearRead; Riverain Technologies) was applied to paired inspiratory/expiratory chest radiographs of 107 patients (normal, 33; abnormal, 74) to create corresponding bone suppression images. The abnormal subjects had been diagnosed with pulmonary diseases, such as pneumothorax, pneumonia, emphysema, asthma, and lung cancer. After recognition of the lung area, the vectors of respiratory displacement were measured in all local lung areas using a cross-correlation technique. The measured displacement in each area was visualized as displacement color maps. The distribution pattern of respiratory displacement was assessed by comparison with the findings of lung scintigraphy. Results: Respiratory displacement of pulmonary markings (soft tissues) was able to be quantified separately from the rib movements on bone suppression images. The resulting displacement map showed a left-right symmetric distribution increasing from the lung apex to the bottom region of the lung in many cases. However, patients with ventilatory impairments showed a nonuniform distribution caused by decreased displacement of pulmonary markings, which were confirmed to correspond to area with ventilatory impairments found on the lung scintigrams. Conclusion: The bone suppression technique was useful for quantitative analysis of respiratory displacement of pulmonary markings without any interruption of the rib shadows. Abnormal areas could be detected as decreased displacement of pulmonary markings. Inspiratory/expiratory chest radiography combined

  12. NOAA People Empowered Products (PeEP): Combining social media with scientific models to provide eye-witness confirmed products

    Science.gov (United States)

    Codrescu, S.; Green, J. C.; Redmon, R. J.; Minor, K.; Denig, W. F.; Kihn, E. A.

    2013-12-01

    NOAA products and alerts rely on combinations of models and data to provide the public with information regarding space and terrestrial weather phenomena and hazards. This operational paradigm, while effective, neglects an abundant free source of measurements: millions of eyewitnesses viewing weather events. We demonstrate the capabilities of a prototype People Empowered Product (PeEP) that combines the OVATION prime auroral model running at the NOAA National Geophysical Data Center with Twitter reports of observable aurora. We introduce an algorithm for scoring Tweets based on keywords to improve the signal to noise of this dynamic data source. We use the location of the aurora derived from this new database of crowd sourced observations to validate the OVATION model for use in auroral forecasting. The combined product displays the model aurora in real time with markers showing the location and text of tweets from people actually observing the aurora. We discuss how the application might be extended to other space weather products such as radiation related satellite anomalies.

  13. Flow-controlled expiration: a novel ventilation mode to attenuate experimental porcine lung injury.

    Science.gov (United States)

    Goebel, U; Haberstroh, J; Foerster, K; Dassow, C; Priebe, H-J; Guttmann, J; Schumann, S

    2014-09-01

    Whereas the effects of various inspiratory ventilatory modifications in lung injury have extensively been studied, those of expiratory ventilatory modifications are less well known. We hypothesized that the newly developed flow-controlled expiration (FLEX) mode provides a means of attenuating experimental lung injury. Experimental acute respiratory distress syndrome was induced by i.v. injection of oleic acid in 15 anaesthetized and mechanically ventilated pigs. After established lung injury ([Formula: see text]ratio ventilation (VCV) or a treatment group receiving VCV with additional FLEX (VCV+FLEX). At predefined times, lung mechanics and oxygenation were assessed. At the end of the experiment, the pigs were killed, and bronchoalveolar fluid and lung biopsies were taken. Expression of inflammatory cytokines was analysed in lung tissue and bronchoalveolar fluid. Lung injury score was determined on the basis of stained tissue samples. Compared with the control group (VCV; n=8), the VCV+FLEX group (n=7) demonstrated greater dynamic lung compliance and required less PEEP at comparable [Formula: see text] (both Pprotective ventilation. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Experimental Study of Dispersion and Deposition of Expiratory Aerosols in Aircraft Cabins and Impact on Infectious Disease Transmission

    DEFF Research Database (Denmark)

    To, G.N.S.; Wan, M.P.; Chao, C.Y.H.

    2009-01-01

    The dispersion and deposition characteristics of polydispersed expiratory aerosols were investigated in an aircraft cabin mockup to study the transmission of infectious diseases. The airflow was characterized by particle image velocimetry (PIV) measurements. Aerosol dispersionwas measured...

  15. Changes in Cross-Sectional Area and Transverse Diameter of the Heart on Inspiratory and Expiratory Chest CT: Correlation with Changes in Lung Size and Influence on Cardiothoracic Ratio Measurement.

    Directory of Open Access Journals (Sweden)

    Hayato Tomita

    Full Text Available The aim of this study was to investigate physiological changes in cardiac area and diameters between inspiratory and expiratory chest computed tomography (CT, and to assess their correlation with lung size change and influence on cardiothoracic ratio (CTR measurements.The institutional review board of our institution approved this study, and informed consent was waived. Forty-three subjects underwent inspiratory and expiratory chest CT as part of routine clinical care. On both inspiratory and expiratory scans, lung volumes and maximum lung diameters (transverse and vertical directions were measured. The maximum cardiac cross-sectional area (CSA and the maximum transverse cardiac diameter were measured on both scans, and the CT-based CTR was calculated. Changes in the lung and cardiac measurements were expressed as the expiratory/inspiratory (E/I ratios. Comparisons between inspiratory and expiratory measurements were made by the Wilcoxon signed-rank test. Correlations between the E/I ratios of lung and heart measurements were evaluated by Spearman's rank correlation analysis.Cardiac CSA and transverse cardiac diameter was significantly larger on expiratory than on inspiratory CT (p < 0.0001. Significant negative correlations were found between the E/I ratios of these cardiac measurements and the E/I ratios of lung volume and vertical lung diameter (p < 0.01. CT-based CTR was significantly larger on expiration than on inspiration (p < 0.0001.Heart size on chest CT depends on the phase of ventilation, and is correlated with changes in lung volume and craniocaudal lung diameter. The CTR is also significantly influenced by ventilation.

  16. Plugger guide for aligning an end plug and a fuel rod tube end

    International Nuclear Information System (INIS)

    Klapper, K.K.; Boatwright, D.A.

    1987-01-01

    A pin driving tool is described for inserting or removing pins from teeth on a digging means, comprising: fuel rod tube toward an end plug for application of the end plug into the tube end, the apparatus comprising: (a) a guide housing having an elongated central longitudinal bore with one end for receiving the end plug and an opposite end for receiving the fuel rod tube end; (b) sets of rolling elements disposed in the housing at axially spaced positions along and about the bore thereof. The rolling elements in each set are positioned in fixed relation with respect to one another to receive the fuel rod tube end therebetween and align the tube end with the end plug as the tube end is moved through the bore and into engagement with the end plug; and (c) retaining means disposed adjacent to the open end of the housing bore for engaging the end plug so as to maintain it in a stationary seated position at the one end of the housing bore

  17. Peak expiratory flow rate in healthy children aged 6-17 years

    DEFF Research Database (Denmark)

    Høst, A; Høst, A H; Ibsen, T

    1994-01-01

    Peak expiratory flow rate (PEFR) was measured in a cross-sectional study in 861 healthy Danish schoolchildren aged 6-17 years using a Mini Wright peak flowmeter. We found a strong correlation between PEFR and height, age and sex. The results were comparable with those from previous studies using...... a Wright peak flowmeter. The equation for prediction of PEFR in boys was calculated as (3.8 x height) + (10.6 x age) - 313.2 (p age) - 143.9 (p ... coefficient in this large sample. Among healthy children without previous asthma, earlier episodes of recurrent wheezing were reported in 8.8% and a significantly lower PEFR was found in this group....

  18. Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review.

    Science.gov (United States)

    Ai, Z T; Melikov, A K

    2018-07-01

    This article reviews past studies of airborne transmission between occupants in indoor environments, focusing on the spread of expiratory droplet nuclei from mouth/nose to mouth/nose for non-specific diseases. Special attention is paid to summarizing what is known about the influential factors, the inappropriate simplifications of the thermofluid boundary conditions of thermal manikins, the challenges facing the available experimental techniques, and the limitations of available evaluation methods. Secondary issues are highlighted, and some new ways to improve our understanding of airborne transmission indoors are provided. The characteristics of airborne spread of expiratory droplet nuclei between occupants, which are influenced correlatively by both environmental and personal factors, were widely revealed under steady-state conditions. Owing to the different boundary conditions used, some inconsistent findings on specific influential factors have been published. The available instrumentation was too slow to provide accurate concentration profiles for time-dependent evaluations of events with obvious time characteristics, while computational fluid dynamics (CFD) studies were mainly performed in the framework of inherently steady Reynolds-averaged Navier-Stokes modeling. Future research needs in 3 areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Successful use of non-invasive positive pressure ventilation in a complicated flail chest

    International Nuclear Information System (INIS)

    Al-Ansari, Mariam A.

    2006-01-01

    The current advanced trauma life support manual states that patients with significant hypoxia (namely, SaO2<90% on room air) as a result of pulmonary contusion should be intubated and ventilated within the first hour of injury. Recently, several researchers have shown improved outcomes when patients with acute respiratory failure are managed with noninvasive positive pressure ventilation (NIPPV). Trauma patients may also benefit from this therapy. We report a case of 15-year-old boy who isolated flail chest and pulmonary contusion, who was intubated in the emergency room, and was managed successfully with the NIPPV in the intensive care unit (ICU) despite, having had aspiration pneumonia early in the course of her stay. After initial stabilization, he failed a spontaneous breathing trial. Due to absence of contraindications to the use of NIPPV, the patient was extubated on day 7 (from pressure ventilation of 15 cmH2O and positive end expiratory pressure of 8 cm H2O) to immediate NIPPV use. Three days later (after a total of 50 hours of NIPPV use in the ICU) the patient was successfully discharged home. (author)

  20. High Flow Nasal Cannula Therapy for Improving Obstructive Sleep Apnea: A Case Report

    Directory of Open Access Journals (Sweden)

    Se Joong Kim

    2015-06-01

    Full Text Available Although continuous positive airway pressure is the treatment of choice for obstructive sleep apnea, its compliance is low. Therefore, alternative therapeutic strategies are often required. High flow nasal cannula therapy uses an air compressor to deliver a constant flow of oxygen via the nasal cannula at a maximum of 60 L/m. It can produce positive end expiratory pressure and increase end expiratory pharyngeal pressure, which can help to alleviate upper airway obstruction. This is a case report of high flow nasal cannula therapy for a 71 year-old man. He had an obstructive sleep apnea and severe desaturation but failed to use continuous positive airway pressure. He underwent titration with high flow nasal cannula under polysomnography. Using high flow nasal cannula at an airflow of 45 L/m, his apnea-hypopnea, respiratory arousal and oxygen desaturation were improved. Importantly, he is very compliant with high flow nasal cannula therapy.

  1. Rationale and study design of PROVHILO - a worldwide multicenter randomized controlled trial on protective ventilation during general anesthesia for open abdominal surgery

    NARCIS (Netherlands)

    Hemmes, S.N.T.; Severgnini, P.; Jaber, S.; Canet, J.; Wrigge, H.; Hiesmayr, M.; Tschernko, E.M.; Hollmann, M.W.; Binnekade, J.M.; Hedenstierna, G.; Putensen, C.; Gama de Abreu, M.; Pelosi, P.; Schultz, M.J.

    2011-01-01

    ABSTRACT: BACKGROUND: Post-operative pulmonary complications add to the morbidity and mortality of surgical patients, in particular after general anesthesia > 2 hours for abdominal surgery. Whether a protective mechanical ventilation strategy with higher levels of positive end-expiratory pressure

  2. Current concepts of protective ventilation during general anaesthesia

    NARCIS (Netherlands)

    Serpa Neto, Ary; Schultz, Marcus J.; Slutsky, Arthur S.

    2015-01-01

    Mechanical ventilation with high tidal volumes (VT) has been common practice in operating theatres because this strategy recruits collapsed lung tissue and improves ventilation-perfusion mismatch, thus decreasing the need for high inspired oxygen concentrations. Positive end-expiratory pressure

  3. Protective ventilation reduces Pseudomonas aeruginosa growth in lung tissue in a porcine pneumonia model.

    Science.gov (United States)

    Sperber, Jesper; Nyberg, Axel; Lipcsey, Miklos; Melhus, Åsa; Larsson, Anders; Sjölin, Jan; Castegren, Markus

    2017-08-31

    Mechanical ventilation with positive end expiratory pressure and low tidal volume, i.e. protective ventilation, is recommended in patients with acute respiratory distress syndrome. However, the effect of protective ventilation on bacterial growth during early pneumonia in non-injured lungs is not extensively studied. The main objectives were to compare two different ventilator settings on Pseudomonas aeruginosa growth in lung tissue and the development of lung injury. A porcine model of severe pneumonia was used. The protective group (n = 10) had an end expiratory pressure of 10 cm H 2 O and a tidal volume of 6 ml x kg -1 . The control group (n = 10) had an end expiratory pressure of 5 cm H 2 O and a tidal volume of 10 ml x kg -1 . 10 11 colony forming units of Pseudomonas aeruginosa were inoculated intra-tracheally at baseline, after which the experiment continued for 6 h. Two animals from each group received only saline, and served as sham animals. Lung tissue samples from each animal were used for bacterial cultures and wet-to-dry weight ratio measurements. The protective group displayed lower numbers of Pseudomonas aeruginosa (p protective group was unchanged (p protective ventilation with lower tidal volume and higher end expiratory pressure has the potential to reduce the pulmonary bacterial burden and the development of lung injury.

  4. The SWAN Captures Variance at the Negative and Positive Ends of the ADHD Symptom Dimension

    Science.gov (United States)

    Arnett, Anne B.; Pennington, Bruce F.; Friend, Angela; Willcutt, Erik G.; Byrne, Brian; Samuelsson, Stefan; Olson, Richard K.

    2013-01-01

    Objective: The Strengths and Weaknesses of ADHD Symptoms and Normal Behavior (SWAN) Rating Scale differs from previous parent reports of ADHD in that it was designed to also measure variability at the positive end of the symptom spectrum. Method: The psychometric properties of the SWAN were tested and compared with an established measure of ADHD,…

  5. Effects of brief smoking cessation education with expiratory carbon monoxide measurement on level of motivation to quit smoking.

    Science.gov (United States)

    Choi, Won-Young; Kim, Cheol-Hwan; Lee, Ok-Gyu

    2013-05-01

    Smoking rates among Korean adult males is still high despite multifaceted efforts to reduce it. In Korea, there have been several studies on the effectiveness of smoking cessation education for inpatients, health check-ups, and smoking cessation clinics. However, there haven't been any studies on the effectiveness of smoking cessation education conducted outside the hospital. This study investigated effectiveness of brief education on smoking cessation with an expiratory carbon monoxide (CO) measurement outside the hospital among adult male office-workers in Korea. From April 1st to May 10th, 2012, we conducted a controlled trial among 95 adult male office workers over the age of 19 who smoke outside, in a public place in Seoul by cluster sampling. For the education group, we provided smoking cessation education for about 5 to 10 minutes, measured the expiratory CO level, and made the subjects complete questionnaires, while only self-help materials on quitting smoking were given to the control group. After 4 weeks, we evaluated the change in the level of motivation or success to quit smoking in both groups via e-mail or mobile phone. In the education group, the level of motivation to quit smoking was improved significantly. A multiple logistic regression analysis showed that the odds ratio of improved motivation to quit smoking in the education group was 28.10 times higher than that of the control group. Brief education on smoking cessation with expiratory CO measurement conducted outside the hospital could enhance the level of motivation to quit smoking.

  6. Mild hypothermia increases pulmonary anti-inflammatory response during protective mechanical ventilation in a piglet model of acute lung injury.

    Science.gov (United States)

    Cruces, Pablo; Erranz, Benjamín; Donoso, Alejandro; Carvajal, Cristóbal; Salomón, Tatiana; Torres, María Fernanda; Díaz, Franco

    2013-11-01

    The effects of mild hypothermia (HT) on acute lung injury (ALI) are unknown in species with metabolic rate similar to that of humans, receiving protective mechanical ventilation (MV). We hypothesized that mild hypothermia would attenuate pulmonary and systemic inflammatory responses in piglets with ALI managed with a protective MV. Acute lung injury (ALI) was induced with surfactant deactivation in 38 piglets. The animals were then ventilated with low tidal volume, moderate positive end-expiratory pressure (PEEP), and permissive hypercapnia throughout the experiment. Subjects were randomized to HT (33.5°C) or normothermia (37°C) groups over 4 h. Plasma and tissue cytokines, tissue apoptosis, lung mechanics, pulmonary vascular permeability, hemodynamic, and coagulation were evaluated. Lung interleukin-10 concentrations were higher in subjects that underwent HT after ALI induction than in those that maintained normothermia. No difference was found in other systemic and tissue cytokines. HT did not induce lung or kidney tissue apoptosis or influence lung mechanics or markers of pulmonary vascular permeability. Heart rate, cardiac output, oxygen uptake, and delivery were significantly lower in subjects that underwent HT, but no difference in arterial lactate, central venous oxygen saturation, and coagulation test was observed. Mild hypothermia induced a local anti-inflammatory response in the lungs, without affecting lung function or coagulation, in this piglet model of ALI. The HT group had lower cardiac output without signs of global dysoxia, suggesting an adaptation to the decrease in oxygen uptake and delivery. Studies are needed to determine the therapeutic role of HT in ALI. © 2013 John Wiley & Sons Ltd.

  7. Apparatus and method for applying an end plug to a fuel rod tube end

    International Nuclear Information System (INIS)

    Rieben, S.L.; Wylie, M.E.

    1987-01-01

    An apparatus is described for applying an end plug to a hollow end of a nuclear fuel rod tube, comprising: support means mounted for reciprocal movement between remote and adjacent positions relative to a nuclear fuel rod tube end to which an end plug is to be applied; guide means supported on the support means for movement; and drive means coupled to the support means and being actuatable for movement between retracted and extended positions for reciprocally moving the support means between its respective remote and adjacent positions. A method for applying an end plug to a hollow end of a nuclear fuel rod tube is also described

  8. Liberação de pressão de vias aéreas em pacientes pediátricos submetidos à cirurgia cardíaca Airway pressure release ventilation in post operative cardiac surgery in pediatric patients

    Directory of Open Access Journals (Sweden)

    W. B. de Carvalho

    2000-06-01

    positive end expiratory pressure (IMV+PEEP, APRV and continuous positive airway pressure (CPAP in children during cardiac surgery post operative with pulmonary hypertension and mild or moderate pulmonary lesion. METHODS: Ten patients were studied with respiratory monitoring (Bear Neonatal Volume Monitor-1Ò in MV with a continuos flow, time cycled and pressure limited ventilator. The cardiocirculatory variables analyzed were central venous pressure (CVP, oxygen extraction ratio, cardiac rate, systolic arterial pressure, and arterial- mixed venous CO2 difference. Friedman's test (non-parametric was used to compare the variables in three modalities of ventilation and the Wilcoxon test was used for the variables obtained in two of the modalities. RESULTS: The mean airway pressure (MAP showed a significant increasing during APRV compared to IMV+PEEP (p=0,012. The positive inspiratory pressure (PIP, the minute volume and the ratio of oxygen arterial pressure to oxygen inspired fraction (PaO2/FiO2 didn't show statistical difference. During APRV there was a significant decrease in respiratory rate (p= 0,004 and an increase in tidal volume (p=0,045 when compared to CPAP and IMV+PEEP. In the cardiocirculatory system only CVP showed a significant increased (p=0,019 during APRV. CONCLUSION: Due to the methodology utilized MAP was higher with APRV resulting in an increased tidal volume without respiratory or cardiocirculatory adverse effects when the three modes were compared. Our results suggest that APRV is a simple and safe method of ventilation.

  9. Respiratory system mechanics during laparoscopic cholecystectomy.

    Science.gov (United States)

    Rizzotti, L; Vassiliou, M; Amygdalou, A; Psarakis, Ch; Rasmussen, T R; Laopodis, V; Behrakis, P

    2002-04-01

    The influence of laparoscopic cholecystectomy (LC) on the mechanical properties of the respiratory system (RS) was examined using multiple regression analysis (MRA). Measurements of airway pressure (PaO) and flow (V') were obtained from 32 patients at four distinct stages of the LC procedure: 1) Immediately before the application of pneumoperitoneum (PP) at supine position, 2) 5 min after the induction of PP at Trendelenburg position, 3) 5 min after the patients position at reverse Trendelenburg, and 4) 5 min after the end ofthe surgical procedure with the patient again in supine position. Evaluated parameters were the RS elastance (Ers), resistance (Rrs), impedance (Zrs), the angle theta indicating the balance between the elastic and resistive components of the impedance, as well as the end-expiratory elastic recoil pressure (EEP). Ers and Zrs increased considerably during PP and remained elevated immediately after abolishing PP Rrs, on the contrary, returned to pre-operative levels right after the operation. Change of body position from Trendelenburg (T) to reverseTrendelenburg (rT) mainly induced a significant change in theta, thus indicating an increased dominance of the elastic component of Zrs on changing fromT to rT. There was no evidence of increased End-Expiratory Pressure during PP

  10. The bedding environment, sleep position, and frequent wheeze in childhood.

    Science.gov (United States)

    Ponsonby, Anne-Louise; Dwyer, Terence; Trevillian, Leigh; Kemp, Andrew; Cochrane, Jennifer; Couper, David; Carmichael, Allan

    2004-05-01

    Synthetic quilt use has been associated with increased childhood wheeze in previous studies. Our aim was to examine whether the adverse effect of synthetic quilt use on frequent wheeze differed by usual sleep position. A population-based cross-sectional study of 6378 (92% of those eligible) 7-year-olds in Tasmania, Australia, was conducted in 1995. Exercise-challenge lung function was obtained on a subset of 414 children from randomly selected schools. Child bedding including pillow and overbedding composition and usual sleep position by parental questionnaire. Frequent wheeze (>12 wheeze episodes over the past year), using the International Study of Asthma and Allergies in Childhood parental questionnaire, and baseline and postexercise forced expiratory volume in 1 second lung-function measures. Frequent wheeze (n = 117) was positively associated with synthetic quilts, synthetic pillows, electric blankets, and sleeping in a bottom bunk bed but did not vary by sleep position. In a nested case-control analysis, the association between synthetic quilt use and frequent wheeze differed by sleep position. Among children who slept supine, synthetic (versus feather) quilt use was associated with frequent wheeze (adjusted odds ratio: 2.37 [1.08, 5.23]). However, among nonsupine sleepers, overlying synthetic quilt use was not associated with frequent wheeze (adjusted odds ratio: 1.06 [0.60, 1.88]). This difference in quilt effect by sleep position was highly significant. Similarly, synthetic quilt use was associated with lower postexercise forced expiratory volume in 1 second measures among supine but not nonsupine sleeping children. An increasing focus on the bedding environment immediately adjacent to the nose and mouth is required for respiratory disorders provoked by bedding, such as child asthma characterized by frequent wheeze.

  11. High flow nasal cannula for respiratory support in preterm infants.

    LENUS (Irish Health Repository)

    Wilkinson, Dominic

    2011-01-01

    High flow nasal cannulae (HFNC) are small, thin, tapered cannulae used to deliver oxygen or blended oxygen and air at flow rates of > 1 L\\/min. HFNC can be used to provide high concentrations of oxygen and may deliver positive end-expiratory pressure.

  12. Neurally adjusted ventilatory assist decreases ventilator-induced lung injury and non-pulmonary organ dysfunction in rabbits with acute lung injury

    NARCIS (Netherlands)

    Brander, Lukas; Sinderby, Christer; Lecomte, François; Leong-Poi, Howard; Bell, David; Beck, Jennifer; Tsoporis, James N.; Vaschetto, Rosanna; Schultz, Marcus J.; Parker, Thomas G.; Villar, Jesús; Zhang, Haibo; Slutsky, Arthur S.

    2009-01-01

    OBJECTIVE: To determine if neurally adjusted ventilatory assist (NAVA) that delivers pressure in proportion to diaphragm electrical activity is as protective to acutely injured lungs (ALI) and non-pulmonary organs as volume controlled (VC), low tidal volume (Vt), high positive end-expiratory

  13. Effect of the radiofrequency volumetric tissue reduction of inferior turbinate on expiratory nasal sound frequency.

    Science.gov (United States)

    Seren, Erdal

    2009-01-01

    We sought to evaluate the short-term efficacy of radiofrequency volumetric tissue reduction (RFVTR) in treatment of inferior turbinate hypertrophy (TH) as measured by expiratory nasal sound spectra. In our study, we aimed to investigate the Odiosoft-rhino (OR) as a new diagnostic method to evaluate the nasal airflow of patients before and after RFVTR. In this study, we have analyzed and recorded the expiratory nasal sound in patients with inferior TH before and after RFVTR. This analysis includes the time expanded waveform, the spectral analysis with time averaged fast Fourier transform (FFT), and the waveform analysis of nasal sound. We found an increase in sound intensity at high frequency (Hf) in the sound analyses of the patients before RFVTR and a decrease in sound intensity at Hf was found in patients after RFVTR. This study indicates that RFVTR is an effective procedure to improve nasal airflow in the patients with nasal obstruction with inferior TH. We found significant decreases in the sound intensity level at Hf in the sound spectra after RFVTR. The OR results from the 2000- to 4000-Hz frequency (Hf) interval may be more useful in assessing patients with nasal obstruction than other frequency intervals. OR may be used as a noninvasive diagnostic tool to evaluate the nasal airflow.

  14. Whole-lung volume and density in spirometrically-gated inspiratory and expiratory CT in systemic sclerosis: correlation with static volumes at pulmonary function tests.

    Science.gov (United States)

    Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M

    2013-03-01

    Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.

  15. Mechanical ventilation management during extracorporeal membrane oxygenation for acute respiratory distress syndrome: a retrospective international multicenter study.

    Science.gov (United States)

    Schmidt, Matthieu; Stewart, Claire; Bailey, Michael; Nieszkowska, Ania; Kelly, Joshua; Murphy, Lorna; Pilcher, David; Cooper, D James; Scheinkestel, Carlos; Pellegrino, Vincent; Forrest, Paul; Combes, Alain; Hodgson, Carol

    2015-03-01

    To describe mechanical ventilation settings in adult patients treated for an acute respiratory distress syndrome with extracorporeal membrane oxygenation and assess the potential impact of mechanical ventilation settings on ICU mortality. Retrospective observational study. Three international high-volume extracorporeal membrane oxygenation centers. A total of 168 patients treated with extracorporeal membrane oxygenation for severe acute respiratory distress syndrome from January 2007 to January 2013. We analyzed the association between mechanical ventilation settings (i.e. plateau pressure, tidal volume, and positive end-expiratory pressure) on ICU mortality using multivariable logistic regression model and Cox-proportional hazards model. We obtained detailed demographic, clinical, daily mechanical ventilation settings and ICU outcome data. One hundred sixty-eight patients (41 ± 14 years old; PaO2/FIO2 67 ± 19 mm Hg) fulfilled our inclusion criteria. Median duration of extracorporeal membrane oxygenation and ICU stay were 10 days (6-18 d) and 28 days (16-42 d), respectively. Lower positive end-expiratory pressure levels and significantly lower plateau pressures during extracorporeal membrane oxygenation were used in the French center than in both Australian centers (23.9 ± 1.4 vs 27.6 ± 3.7 and 27.8 ± 3.6; p Protective mechanical ventilation strategies were routinely used in high-volume extracorporeal membrane oxygenation centers. However, higher positive end-expiratory pressure levels during the first 3 days on extracorporeal membrane oxygenation support were independently associated with improved survival. Further prospective trials on the optimal mechanical ventilation strategy during extracorporeal membrane oxygenation support are warranted.

  16. Method and apparatus for shape and end position determination using an optical fiber

    Science.gov (United States)

    Moore, Jason P. (Inventor)

    2010-01-01

    A method of determining the shape of an unbound optical fiber includes collecting strain data along a length of the fiber, calculating curvature and bending direction data of the fiber using the strain data, curve-fitting the curvature and bending direction data to derive curvature and bending direction functions, calculating a torsion function using the bending direction function, and determining the 3D shape from the curvature, bending direction, and torsion functions. An apparatus for determining the 3D shape of the fiber includes a fiber optic cable unbound with respect to a protective sleeve, strain sensors positioned along the cable, and a controller in communication with the sensors. The controller has an algorithm for determining a 3D shape and end position of the fiber by calculating a set of curvature and bending direction data, deriving curvature, bending, and torsion functions, and solving Frenet-Serret equations using these functions.

  17. A study of pulmonary function in end-stage renal disease patients on hemodialysis: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Ashima Sharma

    Full Text Available ABSTRACT BACKGROUND: The aim here was to study acute effects of hemodialysis among end-stage renal disease (ESRD patients. DESIGN AND SETTING: Prospective study in tertiary-level care center. METHODS: Fifty ESRD patients undergoing hemodialysis were studied. Spirometric pulmonary function tests were performed before and after four-hour hemodialysis sessions. RESULTS: The patients’ average age was 45.8 ± 10.0 years; 64% were males and 64% had normal body mass index. Anemia (94% and hypoalbuminemia (72% were common. Diabetes mellitus (68%, hypertension (34% and coronary artery disease (18% were major comorbidities. Forty-five patients (90% had been on hemodialysis for six months to three years. The patients’ pre-dialysis mean forced vital capacity (FVC and forced expiratory volume in 1 second (FEV1 were below normal: 45.8 ± 24.9% and 43.5 ± 25.9% of predicted, respectively. After hemodialysis, these increased significantly, to 51.1 ± 23.4% and 49.3 ± 25.5% of predicted, respectively (P 0.05. The pre-dialysis mean forced expiratory flow 25-75% was 50.1 ± 31% and increased significantly, to 56.3 ± 31.6% of predicted (P < 0.05. The mean peak expiratory flow was below normal (43.8 ± 30.7% and increased significantly, to 49.1 ± 29.9% of predicted (P < 0.05. Males and females showed similar directions of change after hemodialysis. CONCLUSIONS: Pulmonary function abnormalities are common among ESRD patients. Comparison of pre and post-hemodialysis parameters showed significant improvements, but normal predicted values were still not achieved.

  18. Clearance of 99mTc-labeled albumin from lungs in anesthetized guinea pigs

    International Nuclear Information System (INIS)

    Connelly, J.C.; Peterson, B.T.

    1993-01-01

    Gamma imaging was used to measure the rate of clearance of aerosolized 99m Tc-human serum albumin (HSA) from the lungs of control guinea pigs and guinea pigs that received increased lung inflation or lung injury. Anesthetized guinea pigs were ventilated for 6 min with an aerosol of HSA and the radioactivity in the chest was monitored for 2 h with a gamma camera to determine whether the clearance rate would be a reliable assessment of lung epithelial permeability. Increased lung volumes were effected by application of 5 or 7 cm H 2 O positive end-expired pressure (5-PEEP and 7-PEEP, respectively). Lung injury was induced either by intravenous oleic acid (OA, 27-73 μl/kg) or inhalation of nitrogen dioxide (NO 2 , 80-100 ppm) for 2 h. Postmortem extravascular lung water volume (EVLW) provided an assessment of the degree of lung injury. Tracer clearance rates in animals receiving 5 or 7 cm H 2 O PEEP were not significantly different from controls (K = 0.15 ± 0.05 and 0.24 ± 0.10 vs 0.12 ± 0.03%/min, respectively, p > .05). Animals exposed to NO 2 had faster tracer clearance rates (K = 0.33 ± 0.21%/min, p 2 -exposed guinea pigs correlated well with injury as assessed by EVLW (r = .93, p 2 O PEEP (K = 0.58 ± 0.41%/min, EVLW = 8.1 ± 0.8 mL/g dry lung tissue, p < .05), but there was no correlation between these parameters in this injury model. It is concluded that imaging of the disappearance of radiolabeled HSA in the guinea pig can be a useful index of lung epithelial permeability, but this technique is limited to certain models of lung injury. 33 refs

  19. [Effect of transpulmonary pressure-directed mechanical ventilation on respiration in severe acute pancreatitis patient with intraabdominal hypertension].

    Science.gov (United States)

    Wu, Xiaoyan; Zheng, Ruiqiang; Lin, Hua; Zhuang, Zhiqing; Zhang, Min; Yan, Peixia

    2015-10-20

    To assess the effect of mehanical ventilation (MV) guided by transpulmonary pressure (Ptp) on respiratory mechanics and gas exchange in severe acute pancreatitis patient with intraabdominal hypertension. Twelve severe acute pancreatitis patient with intraabdominal hypertension and acute respiratory distress syndrome(ARDS) underwent mechanical ventilation were involved from Jan to Dec 2013. PEEP levels were set to achieve a Ptp of 0 to 10 cm of water at end expiration. We also limited tidal volume to keep Ptp at less than 25 cm of water at end inspiration. Respiratory mechanics and gas-exchange were measured. Plat pressure (Pplat) increased and the compliance of chest wall (Ccw) decreased when intraabdominal pressure (IAP) increased. Pplat correlated with IAP positively (r2=0.741 9, P0.05). Compared with baseline, after guiding MV with Ptp, the Level of PEEP (14.6±4.2) cmH2O vs (8.3±2.0) cmH2O, and Ptp-e (1.5±0.5) cmH2O vs (-2.3±1.4) cmH2O increased (P0.05). Ptp-e correlated with PEEP (r2=0.549, P0.05). Compared with baseline, lung compliance (CL) (48.1±10.3) cmH2O vs (25.7±6.4) cmH2O and oxygenation index (PaO2/FiO2) (235±48) mmHg vs (160±35) mmHg improved obviously (P0.05). Transpulmonary pressure-directed mechanical ventilation in ARDS secondary to severe acute pancreatitis patient with intraabdominal hypertension could not only recruit the collapsed alveoli, improve lung compliance, increase oxygenation index and decrease dead space ventilation but also monitor lung stress to avoid alveoli overinflation, which might be lung protective.

  20. Auto-trilevel versus bilevel positive airway pressure ventilation for hypercapnic overlap syndrome patients.

    Science.gov (United States)

    Su, Mei; Huai, De; Cao, Juan; Ning, Ding; Xue, Rong; Xu, Meijie; Huang, Mao; Zhang, Xilong

    2018-03-01

    Although bilevel positive airway pressure (Bilevel PAP) therapy is usually used for overlap syndrome (OS), there is still a portion of OS patients in whom Bilevel PAP therapy could not simultaneously eliminate residual apnea events and hypercapnia. The current study was expected to explore whether auto-trilevel positive airway pressure (auto-trilevel PAP) therapy with auto-adjusting end expiratory positive airway pressure (EEPAP) can serve as a better alternative for these patients. From January of 2014 to June of 2016, 32 hypercapnic OS patients with stable chronic obstructive pulmonary diseases (COPD) and moderate-to-severe obstructive sleep apnea syndrome (OSAS) were recruited. Three variable modes of positive airway pressure (PAP) from the ventilator (Prisma25ST, Weinmann Inc., Germany) were applicated for 8 h per night. We performed the design of each mode at each night with an interval of two nights with no PAP treatment as a washout period among different modes. In Bilevel-1 mode (Bilevel-1), the expiratory positive airway pressure (EPAP) delivered from Bilevel PAP was always set as the lowest PAP for abolishment of snoring. For each patient, the inspiratory positive airway pressure (IPAP) was constantly set the same as the minimal pressure for keeping end-tidal CO 2 (ETCO 2 ) ≤45 mmHg for all three modes. However, the EPAP issued by Bilevel PAP in Bilevel-2 mode (Bilevel-2) was kept 3 cmH 2 O higher than that in Bilevel-1. In auto-trilevel mode (auto-trilevel) with auto-trilevel PAP, the initial part of EPAP was fixed at the same PAP as that in Bilevel-1 while the EEPAP was automatically regulated to rise at a range of ≤4 cmH 2 O based on nasal airflow wave changes. Comparisons were made for parameters before and during or following treatment as well as among different PAP therapy modes. The following parameters were compared such as nocturnal apnea hypopnea index (AHI), minimal SpO 2 (minSpO 2 ), arousal index, sleep structure and efficiency

  1. Positive selection on the nonhomologous end-joining factor Cernunnos-XLF in the human lineage

    Directory of Open Access Journals (Sweden)

    Jurka Jerzy

    2006-06-01

    Full Text Available Abstract Background Cernunnos-XLF is a nonhomologous end-joining factor that is mutated in patients with a rare immunodeficiency with microcephaly. Several other microcephaly-associated genes such as ASPM and microcephalin experienced recent adaptive evolution apparently linked to brain size expansion in humans. In this study we investigated whether Cernunnos-XLF experienced similar positive selection during human evolution. Results We obtained or reconstructed full-length coding sequences of chimpanzee, rhesus macaque, canine, and bovine Cernunnos-XLF orthologs from sequence databases and sequence trace archives. Comparison of coding sequences revealed an excess of nonsynonymous substitutions consistent with positive selection on Cernunnos-XLF in the human lineage. The hotspots of adaptive evolution are concentrated around a specific structural domain, whose analogue in the structurally similar XRCC4 protein is involved in binding of another nonhomologous end-joining factor, DNA ligase IV. Conclusion Cernunnos-XLF is a microcephaly-associated locus newly identified to be under adaptive evolution in humans, and possibly played a role in human brain expansion. We speculate that Cernunnos-XLF may have contributed to the increased number of brain cells in humans by efficient double strand break repair, which helps to prevent frequent apoptosis of neuronal progenitors and aids mitotic cell cycle progression. Reviewers This article was reviewed by Chris Ponting and Richard Emes (nominated by Chris Ponting, Kateryna Makova, Gáspár Jékely and Eugene V. Koonin.

  2. Prediction of high airway pressure using a non-linear autoregressive model of pulmonary mechanics.

    Science.gov (United States)

    Langdon, Ruby; Docherty, Paul D; Schranz, Christoph; Chase, J Geoffrey

    2017-11-02

    For mechanically ventilated patients with acute respiratory distress syndrome (ARDS), suboptimal PEEP levels can cause ventilator induced lung injury (VILI). In particular, high PEEP and high peak inspiratory pressures (PIP) can cause over distension of alveoli that is associated with VILI. However, PEEP must also be sufficient to maintain recruitment in ARDS lungs. A lung model that accurately and precisely predicts the outcome of an increase in PEEP may allow dangerous high PIP to be avoided, and reduce the incidence of VILI. Sixteen pressure-flow data sets were collected from nine mechanically ventilated ARDs patients that underwent one or more recruitment manoeuvres. A nonlinear autoregressive (NARX) model was identified on one or more adjacent PEEP steps, and extrapolated to predict PIP at 2, 4, and 6 cmH 2 O PEEP horizons. The analysis considered whether the predicted and measured PIP exceeded a threshold of 40 cmH 2 O. A direct comparison of the method was made using the first order model of pulmonary mechanics (FOM(I)). Additionally, a further, more clinically appropriate method for the FOM was tested, in which the FOM was trained on a single PEEP prior to prediction (FOM(II)). The NARX model exhibited very high sensitivity (> 0.96) in all cases, and a high specificity (> 0.88). While both FOM methods had a high specificity (> 0.96), the sensitivity was much lower, with a mean of 0.68 for FOM(I), and 0.82 for FOM(II). Clinically, false negatives are more harmful than false positives, as a high PIP may result in distension and VILI. Thus, the NARX model may be more effective than the FOM in allowing clinicians to reduce the risk of applying a PEEP that results in dangerously high airway pressures.

  3. Comparisons of different mean airway pressure settings during high-frequency oscillation in inflammatory response to oleic acid-induced lung injury in rabbits

    Directory of Open Access Journals (Sweden)

    Koichi Ono

    2009-03-01

    Full Text Available Koichi Ono1, Tomonobu Koizumi2, Rikimaru Nakagawa1, Sumiko Yoshikawa2, Tetsutarou Otagiri11Department of Anesthesiology and Resuscitation; 2First Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, JapanPurpose: The present study was designed to examine effects of different mean airway pressure (MAP settings during high-frequency oscillation (HFO on oxygenation and inflammatory responses to acute lung injury (ALI in rabbits.Methods: Anesthetized rabbits were mechanically ventilated with a conventional mechanical ventilation (CMV mode (tidal volume 6 ml/kg, inspired oxygen fraction [FIo2] of 1.0, respiratory rate [RR] of 30/min, positive end-expiratory pressure [PEEP] of 5 cmH2O. ALI was induced by intravenous administration of oleic acid (0.08 ml/kg and the animals were randomly allocated to the following three experimental groups; animals (n = 6 ventilated using the same mode of CMV, or animals ventilated with standard MAP (MAP 10 cmH2O, n = 7, and high MAP (15 cmH2O, n = 6 settings of HFO (Hz 15. The MAP settings were calculated by the inflation limb of the pressure-volume curve during CMV.Results: HFO with a high MAP setting significantly improved the deteriorated oxygenation during oleic acid-induced ALI and reduced wet/dry ratios, neutrophil counts and interleukin-8 concentration in bronchoalveolar lavage fluid, compared to those parameters in CMV and standard MAP-HFO.Conclusions: These findings suggest that only high MAP setting during HFO could contribute to decreased lung inflammation as well as improved oxygenation during the development of ALI.Keywords: lung protective ventilation, open lung ventilation, IL-8, neutrophil

  4. Positive Rates and Factors Associated with Abnormal Lung Function of Greenhouse Workers in China: A Cross-Sectional Study.

    Science.gov (United States)

    Zhu, Xiaojun; Gao, Panjun; Gu, Yishuo; Xiao, Pei; Liu, Mengxuan; Chen, Juan; Cen, Yacai; Ma, Wenjun; Li, Tao

    2017-08-24

    Since the number of greenhouse workers are increasing in China, this observational cross-sectional study was designed to evaluate lung function and discuss the potential risk factors, to provide evidence in the surveillance of greenhouse workers' health. 678 greenhouse workers in Gansu Province, China were enrolled. A questionnaire which included demographic and occupational information was used. Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 s (FEV₁), and FEV₁:FVC ratios (FEV₁/FVC), maximal expiratory flow after 50% of the FVC has not been exhaled (MEF 50 ), maximal expiratory flow after 25% of the FVC has not been exhaled (MEF 25 ) and maximal mid-expiratory flow curve (MMEF) were measured as lung function indicators. The mean values and standard deviations (SDs) of VC% predicted, FVC% predicted, FEV₁% predicted and FEV₁/FVC ratio were 106.07 ± 13.36, 107.60 ± 13.95, 97.19 ± 14.80 and 89.76 ± 10.78 respectively. The positive rates of above four and abnormal lung ventilation function were 2.9%, 2.8%, 11.2%, 4.6% and 6.5% respectively. Gender, age, BMI and number of greenhouses owned were influence factors of lung ventilation function ( p greenhouses owned were influence factors for small airway function ( p greenhouse might influence lung function of the workers. Small airway function indicators could be used as priority indicators for the surveillance of greenhouse workers' health.

  5. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water

    Directory of Open Access Journals (Sweden)

    Danize Aparecida Rizzetti

    Full Text Available ABSTRACT Objective: To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. Methods: This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP; CPAP5 (CPAP at 5 cmH2O; and CPAP10 (CPAP at 10 cmH2O. We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR, and FEF25-75% at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. Results: We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. Conclusions: When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.

  6. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water.

    Science.gov (United States)

    Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel

    2017-01-01

    To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.

  7. End-tidal control vs. manually controlled minimal-flow anesthesia: a prospective comparative trial.

    Science.gov (United States)

    Wetz, A J; Mueller, M M; Walliser, K; Foest, C; Wand, S; Brandes, I F; Waeschle, R M; Bauer, M

    2017-11-01

    To ensure safe general anesthesia, manually controlled anesthesia requires constant monitoring and numerous manual adjustments of the gas dosage, especially for low- and minimal-flow anesthesia. Oxygen flow-rate and administration of volatile anesthetics can also be controlled automatically by anesthesia machines using the end-tidal control technique, which ensures constant end-tidal concentrations of oxygen and anesthetic gas via feedback and continuous adjustment mechanisms. We investigated the hypothesis that end-tidal control is superior to manually controlled minimal-flow anesthesia (0.5 l/min). In this prospective trial, we included 64 patients undergoing elective surgery under general anesthesia. We analyzed the precision of maintenance of the sevoflurane concentration (1.2-1.4%) and expiratory oxygen (35-40%) and the number of necessary adjustments. Target-concentrations of sevoflurane and oxygen were maintained at more stable levels with the use of end-tidal control (during the first 15 min 28% vs. 51% and from 15 to 60 min 1% vs. 19% deviation from sevoflurane target, P tidal oxygen (5, IQR 3-6). The target-concentrations were reached earlier with the use of end-tidal compared with manual controlled minimal-flow anesthesia but required slightly greater use of anesthetic agents (6.9 vs. 6.0 ml/h). End-tidal control is a superior technique for setting and maintaining oxygen and anesthetic gas concentrations in a stable and rapid manner compared with manual control. Consequently, end-tidal control can effectively support the anesthetist. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Acute chlorine gas exposure produces transient inflammation and a progressive alteration in surfactant composition with accompanying mechanical dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Massa, Christopher B.; Scott, Pamela; Abramova, Elena; Gardner, Carol; Laskin, Debra L.; Gow, Andrew J., E-mail: Gow@rci.rutgers.edu

    2014-07-01

    Acute Cl{sub 2} exposure following industrial accidents or military/terrorist activity causes pulmonary injury and severe acute respiratory distress. Prior studies suggest that antioxidant depletion is important in producing dysfunction, however a pathophysiologic mechanism has not been elucidated. We propose that acute Cl{sub 2} inhalation leads to oxidative modification of lung lining fluid, producing surfactant inactivation, inflammation and mechanical respiratory dysfunction at the organ level. C57BL/6J mice underwent whole-body exposure to an effective 60 ppm-hour Cl{sub 2} dose, and were euthanized 3, 24 and 48 h later. Whereas pulmonary architecture and endothelial barrier function were preserved, transient neutrophilia, peaking at 24 h, was noted. Increased expression of ARG1, CCL2, RETLNA, IL-1b, and PTGS2 genes was observed in bronchoalveolar lavage (BAL) cells with peak change in all genes at 24 h. Cl{sub 2} exposure had no effect on NOS2 mRNA or iNOS protein expression, nor on BAL NO{sub 3}{sup −} or NO{sub 2}{sup −}. Expression of the alternative macrophage activation markers, Relm-α and mannose receptor was increased in alveolar macrophages and pulmonary epithelium. Capillary surfactometry demonstrated impaired surfactant function, and altered BAL phospholipid and surfactant protein content following exposure. Organ level respiratory function was assessed by forced oscillation technique at 5 end expiratory pressures. Cl{sub 2} exposure had no significant effect on either airway or tissue resistance. Pulmonary elastance was elevated with time following exposure and demonstrated PEEP refractory derecruitment at 48 h, despite waning inflammation. These data support a role for surfactant inactivation as a physiologic mechanism underlying respiratory dysfunction following Cl{sub 2} inhalation. - Highlights: • Effect of 60 ppm*hr Cl{sub 2} gas on lung inflammation and mechanical function examined. • Pulmonary inflammation is transient and minor.

  9. Front-end circuit for position sensitive silicon and vacuum tube photomultipliers with gain control and depth of interaction measurement

    International Nuclear Information System (INIS)

    Herrero, Vicente; Colom, Ricardo; Gadea, Rafael; Lerche, Christoph W.; Cerda, Joaquin; Sebastia, Angel; Benlloch, Jose M.

    2007-01-01

    Silicon Photomultipliers, though still under development for mass production, may be an alternative to traditional Vacuum Photomultipliers Tubes (VPMT). As a consequence, electronic front-ends initially designed for VPMT will need to be modified. In this simulation, an improved architecture is presented which is able to obtain impact position and depth of interaction of a gamma ray within a continuous scintillation crystal, using either kind of PM. A current sensitive preamplifier stage with individual gain adjustment interfaces the multi-anode PM outputs with a current division resistor network. The preamplifier stage allows to improve front-end processing delay and temporal resolution behavior as well as to increase impact position calculation resolution. Depth of interaction (DOI) is calculated from the width of the scintillation light distribution, which is related to the sum of voltages in resistor network input nodes. This operation is done by means of a high-speed current mode scheme

  10. Mechanical ventilation with lower tidal volumes and positive end-expiratory pressure prevents alveolar coagulation in patients without lung injury

    NARCIS (Netherlands)

    Choi, Goda; Wolthuis, Esther K.; Bresser, Paul; Levi, Marcel; van der Poll, Tom; Dzoljic, Misa; Vroom, Margreeth B.; Schultz, Marcus J.

    2006-01-01

    BACKGROUND: Alveolar fibrin deposition is a hallmark of acute lung injury, resulting from activation of coagulation and inhibition of fibrinolysis. Previous studies have shown that mechanical ventilation with high tidal volumes may aggravate lung injury in patients with sepsis and acute lung injury.

  11. Distribution of peak expiratory flow variability by age, gender and smoking habits in a random population sample aged 20-70 yrs

    NARCIS (Netherlands)

    Boezen, H M; Schouten, J. P.; Postma, D S; Rijcken, B

    1994-01-01

    Peak expiratory flow (PEF) variability can be considered as an index of bronchial lability. Population studies on PEF variability are few. The purpose of the current paper is to describe the distribution of PEF variability in a random population sample of adults with a wide age range (20-70 yrs),

  12. Modeling the Fate of Expiratory Aerosols and the Associated Infection Risk in an Aircraft Cabin Environment

    DEFF Research Database (Denmark)

    Wan, M.P.; To, G.N.S.; Chao, C.Y.H.

    2009-01-01

    to estimate the risk of infection by contact. The environmental control system (ECS) in a cabin creates air circulation mainly in the lateral direction, making lateral dispersions of aerosols much faster than longitudinal dispersions. Aerosols with initial sizes under 28 m in diameter can stay airborne......The transport and deposition of polydispersed expiratory aerosols in an aircraft cabin were simulated using a Lagrangian-based model validated by experiments conducted in an aircraft cabin mockup. Infection risk by inhalation was estimated using the aerosol dispersion data and a model was developed...

  13. Completion of the first TRT End-cap

    CERN Multimedia

    Catinaccio, A; Rohne, O

    On July 1, the first end-cap of the ATLAS Transition Radiation Tracker (TRT) was successfully completed in terms of the integration of the wheels assembled in Russia with their front-end electronics. The two groups of the detector, fully assembled and equipped with front-end electronics, were rotated from their horizontal position during stacking to their nominal vertical position, in which they will be integrated with the corresponding end-cap silicon-strip (SCT) detector towards the end of 2005, before installation into ATLAS in spring 2006. After starting the assembly in the SR building one year ago, the TRT team reached this important milestone, which marks the final realization and validation of the engineering concept developed by the CERN DT1 (ex-TA1) and ATT teams. A TRT end-cap consists of two sets of identical and independent wheels. The first type of wheels (type A, 12 wheels, positioned closest to the primary interaction point) contains 6144 radial straws positioned in eight successive layers s...

  14. Influence of Changing the Diameter of the Bubble Generator Bottle and Expiratory Limb on Bubble CPAP: An in vitro Study

    Directory of Open Access Journals (Sweden)

    Chun-Shan Wu

    2012-12-01

    Conclusion: The size and submergence depth of an expiratory limb of a CPAP circuit, the diameter of the bubble generator bottle, and the compliance of the model lung all influence the magnitude and frequency of the transmitted pressure waveform. Therefore, these factors may affect lung volume recruitment and breathing efficiency in bubble CPAP.

  15. Effect of a mixture of pyridostigmine and atropine on forced expiratory volume (FEV1), and serum cholinesterase activity in normal subjects

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, B F; Gefke, Kaj; Mosbech, H

    1985-01-01

    injection with a decrease to 27 +/- 5% (mean +/- SEM) of the original activity. Forced expiratory volume in the first 1s (FEV1) was measured at fixed time intervals for 90 min. No decrease in FEV1 was observed; on the contrary, there was a small increase. We conclude that atropine effectively antagonizes...

  16. Normal expiratory flow rate and lung volumes in patients with combined emphysema and interstitial lung disease: a case series and literature review.

    Science.gov (United States)

    Heathcote, Karen L; Cockcroft, Donald W; Fladeland, Derek A; Fenton, Mark E

    2011-01-01

    Pulmonary function tests in patients with idiopathic pulmonary fibrosis characteristically show a restrictive pattern including small lung volumes and increased expiratory flow rates resulting from a reduction in pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. When the diseases coexist, pulmonary volumes are compensated, and a smaller than expected reduction or even normal lung volumes can be found. The present report describes 10 patients with progressive breathlessness, three of whom experienced severe limitation in their quality of life. All patients showed lung interstitial involvement and emphysema on computed tomography scan of the chest. The 10 patients showed normal spirometry and lung volumes with severe compromise of gas exchange. Normal lung volumes do not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.

  17. End-Effector Position Analysis Using Forward Kinematics For 5 Dof Pravak Robot Arm

    Directory of Open Access Journals (Sweden)

    Jolly Atit Shah

    2013-03-01

    Full Text Available Automatic control of the robotic manipulator involves study of kinematics and dynamics as a major issue. This paper involves the kinematic analysis of a Pravak Robot arm which is used for doing successful robotic manipulation task in its workspace. The Pravak Robot Arm is a 5-DOF robot having all the joints revolute. The kinematics problem is defined as the transformation from the Cartesian space to the joint space and vice versa. In this study the Denavit- Hartenberg (D-H model is used to model robot links and joints. Pravak Robot Arm is a simple and safe robotic system designed for laboratory training and research applications. This robot allows to gain theoretical and practical experience in robotics, automation and control systems. The MATLAB R2007 is used to analyse end effectors position for a set of joint parameter.

  18. Efeitos da aplicação da EPAP (Expiratory Positive Airway Pressure sobre a tolerância ao esforço em pacientes portadores de insuficiência cardíaca

    Directory of Open Access Journals (Sweden)

    Claudia Thofehrn

    2013-04-01

    Full Text Available INTRODUÇÃO: Novas abordagens terapêuticas que objetivam melhorar a sensação de dispneia e fadiga em pacientes com insuficiência cardíaca, como a aplicação de pressão positiva expiratória nas vias aéreas (EPAP, podem ser aplicadas na tentativa de melhorar a capacidade funcional e a qualidade de vida. OBJETIVO: Avaliar os efeitos da utilização da EPAP ( Expiratory Positive Airway Pressure durante o esforço em indivíduos portadores de IC classe funcional II e III (NYHA. MÉTODOS: Dos 390 pacientes, foram selecionados 28 com FEVE < 40%. O Teste de Caminhada de seis minutos (TC6' foi realizado três vezes: o primeiro para a familiarização, um com a máscara e o outro sem a máscara de EPAP, sendo válido os dois últimos. A comparação entre os dados obtidos foi realizada por meio de teste t de Student pareado ou teste de Wilcoxon, conforme a normalidade dos dados. RESULTADOS: a percepção de esforço foi maior após a caminhada com a utilização da máscara quando comparado na ausência da máscara. Houve elevação significativa na saturação de oxigênio quando os pacientes estavam usando a máscara de EPAP. CONCLUSÃO: O uso da máscara de EPAP aumenta a percepção de esforço e o trabalho ventilatório, porém, não aumentou a distância percorrida no TC6, sendo sua aplicabilidade questionável em programas de reabilitação cardiovascular.

  19. Numerical and experimental study of expiratory flow in the case of major upper airway obstructions with fluid structure interaction

    Science.gov (United States)

    Chouly, F.; van Hirtum, A.; Lagrée, P.-Y.; Pelorson, X.; Payan, Y.

    2008-02-01

    This study deals with the numerical prediction and experimental description of the flow-induced deformation in a rapidly convergent divergent geometry which stands for a simplified tongue, in interaction with an expiratory airflow. An original in vitro experimental model is proposed, which allows measurement of the deformation of the artificial tongue, in condition of major initial airway obstruction. The experimental model accounts for asymmetries in geometry and tissue properties which are two major physiological upper airway characteristics. The numerical method for prediction of the fluid structure interaction is described. The theory of linear elasticity in small deformations has been chosen to compute the mechanical behaviour of the tongue. The main features of the flow are taken into account using a boundary layer theory. The overall numerical method entails finite element solving of the solid problem and finite differences solving of the fluid problem. First, the numerical method predicts the deformation of the tongue with an overall error of the order of 20%, which can be seen as a preliminary successful validation of the theory and simulations. Moreover, expiratory flow limitation is predicted in this configuration. As a result, both the physical and numerical models could be useful to understand this phenomenon reported in heavy snorers and apneic patients during sleep.

  20. Sensitivity and specificity of hypopnoea detection using nasal pressure in the presence of a nasal expiratory resistive device (Provent®)

    International Nuclear Information System (INIS)

    Milne, Stephen; Amis, Terence C; Wheatley, John R; Kairaitis, Kristina

    2014-01-01

    Nasal expiratory resistive valves (Provent ® ) have been proposed as novel therapy for obstructive sleep apnea. We compared pressure measurements from a standard nasal pressure catheter used to assess nasal airflow during sleep with those from nasal expiratory resistive device with attached proprietary nasal pressure cannula. Nasal pressure cannula or Provent ® + proprietary nasal pressure cannula were attached to a bench model of human anterior nares and nasal passages, and pressure measured (P). Respiratory airflows generated by a subject breathing were applied to rear of model and airflow ( V-dot ) measured via pneumotachograph. Airflow amplitude (Δ V-dot ) was plotted against pressure amplitude (ΔP). Hypopnoea detection (<50% Δ V-dot ) sensitivity and specificity was tested by expressing ΔP in terms of two reference breaths: reference breath 1, Δ V-dot 0.55 L s −1  = 100%; and reference breath 2, Δ V-dot 0.45 L s −1  = 100%. ΔP/Δ V-dot relationships were linear for Δ V-dot  ≤ 0.55 L s −1 ; ΔP = 0.37ΔV + 0.16 (nasal pressure cannula), ΔP = 2.7ΔV + 0.12 (Provent ® + proprietary nasal pressure cannula); both R 2  > 0.65, p < 0.0001; p < 0.0001 for between slope difference). For nasal pressure cannula, specificity of hypopnoea detection differed between reference breaths one and two (80.2% and 40.0%, respectively), and Provent ® + proprietary nasal pressure cannula (30.3% and 74.2%, respectively). Quantification of airflow obstruction in the presence of Provent ® + proprietary nasal pressure cannula is greatly influenced by the reference breath chosen to determine a reduction in nasal airflow. Reported variability in therapeutic response to nasal expiratory resistive devices may relate to differences in measurement technique specificity used to quantify the severity of sleep disordered breathing. (paper)

  1. The death of recency: Relationship between end-state comfort and serial position effects in serial recall: Logan and Fischman (2011) revisited.

    Science.gov (United States)

    Logan, Samuel W; Fischman, Mark G

    2015-12-01

    Two experiments examined the dynamic interaction between cognitive resources in short-term memory and bimanual object manipulation by extending recent research by Logan and Fischman (2011). In Experiment 1, 16 participants completed a bimanual end-state comfort task and a memory task requiring serial recall of 12 words or pictures. The end-state comfort task involved moving two glasses between two shelves. Participants viewed the items, performed the end-state comfort task, and then serially recalled the items. Recall was evaluated by the presence or absence of primacy and recency effects. The end-state comfort effect (ESCE) was assessed by the percentage of initial hand positions that allowed the hands to end comfortably. The main findings indicated that the ESCE was disrupted; the primacy effect remained intact; and the recency effect disappeared regardless of the type of memory item recalled. In Experiment 2, 16 participants viewed six items, performed an end-state comfort task, viewed another six items, and then serially recalled all 12 items. Results were essentially the same as in Experiment 1. Findings suggest that executing a bimanual end-state comfort task, regardless of when it is completed during a memory task, diminishes the recency effect irrespective of the type of memory item. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Variability in usual care mechanical ventilation for pediatric acute lung injury: the potential benefit of a lung protective computer protocol.

    Science.gov (United States)

    Khemani, Robinder G; Sward, Katherine; Morris, Alan; Dean, J Michael; Newth, Christopher J L

    2011-11-01

    Although pediatric intensivists claim to embrace lung protective ventilation for acute lung injury (ALI), ventilator management is variable. We describe ventilator changes clinicians made for children with hypoxemic respiratory failure, and evaluate the potential acceptability of a pediatric ventilation protocol. This was a retrospective cohort study performed in a tertiary care pediatric intensive care unit (PICU). The study period was from January 2000 to July 2007. We included mechanically ventilated children with PaO(2)/FiO(2) (P/F) ratio less than 300. We assessed variability in ventilator management by evaluating actual changes to ventilator settings after an arterial blood gas (ABG). We evaluated the potential acceptability of a pediatric mechanical ventilation protocol we adapted from National Institutes of Health/National Heart, Lung, and Blood Institute (NIH/NHLBI) Acute Respiratory Distress Syndrome (ARDS) Network protocols by comparing actual practice changes in ventilator settings to changes that would have been recommended by the protocol. A total of 2,719 ABGs from 402 patients were associated with 6,017 ventilator settings. Clinicians infrequently decreased FiO(2), even when the PaO(2) was high (>68 mmHg). The protocol would have recommended more positive end expiratory pressure (PEEP) than was used in actual practice 42% of the time in the mid PaO(2) range (55-68 mmHg) and 67% of the time in the low PaO(2) range (ventilator rate (VR) when the protocol would have recommended a change, even when the pH was greater than 7.45 with PIP at least 35 cmH(2)O. There may be lost opportunities to minimize potentially injurious ventilator settings for children with ALI. A reproducible pediatric mechanical ventilation protocol could prompt clinicians to make ventilator changes that are consistent with lung protective ventilation.

  3. Intra-operative protective mechanical ventilation in lung transplantation: a randomised, controlled trial.

    Science.gov (United States)

    Verbeek, G L; Myles, P S; Westall, G P; Lin, E; Hastings, S L; Marasco, S F; Jaffar, J; Meehan, A C

    2017-08-01

    Primary graft dysfunction occurs in up to 25% of patients after lung transplantation. Contributing factors include ventilator-induced lung injury, cardiopulmonary bypass, ischaemia-reperfusion injury and excessive fluid administration. We evaluated the feasibility, safety and efficacy of an open-lung protective ventilation strategy aimed at reducing ventilator-induced lung injury. We enrolled adult patients scheduled to undergo bilateral sequential lung transplantation, and randomly assigned them to either a control group (volume-controlled ventilation with 5 cmH 2 O, positive end-expiratory pressure, low tidal volumes (two-lung ventilation 6 ml.kg -1 , one-lung ventilation 4 ml.kg -1 )) or an alveolar recruitment group (regular step-wise positive end-expiratory pressure-based alveolar recruitment manoeuvres, pressure-controlled ventilation set at 16 cmH 2 O with 10 cmH 2 O positive end-expiratory pressure). Ventilation strategies were commenced from reperfusion of the first lung allograft and continued for the duration of surgery. Regular PaO 2 /F I O 2 ratios were calculated and venous blood samples collected for inflammatory marker evaluation during the procedure and for the first 24 h of intensive care stay. The primary end-point was the PaO 2 /F I O 2 ratio at 24 h after first lung reperfusion. Thirty adult patients were studied. The primary outcome was not different between groups (mean (SD) PaO 2 /F I O 2 ratio control group 340 (111) vs. alveolar recruitment group 404 (153); adjusted p = 0.26). Patients in the control group had poorer mean (SD) PaO 2 /F I O 2 ratios at the end of the surgical procedure and a longer median (IQR [range]) time to tracheal extubation compared with the alveolar recruitment group (308 (144) vs. 402 (154) (p = 0.03) and 18 (10-27 [5-468]) h vs. 15 (11-36 [5-115]) h (p = 0.01), respectively). An open-lung protective ventilation strategy during surgery for lung transplantation is feasible, safe and achieves favourable

  4. Normal Expiratory Flow Rate and Lung Volumes in Patients with Combined Emphysema and Interstitial Lung Disease: A Case Series and Literature Review

    Directory of Open Access Journals (Sweden)

    Karen L Heathcote

    2011-01-01

    Full Text Available Pulmonary function tests in patients with idiopathic pulmonary fibrosis characteristically show a restrictive pattern including small lung volumes and increased expiratory flow rates resulting from a reduction in pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. When the diseases coexist, pulmonary volumes are compensated, and a smaller than expected reduction or even normal lung volumes can be found. The present report describes 10 patients with progressive breathlessness, three of whom experienced severe limitation in their quality of life. All patients showed lung interstitial involvement and emphysema on computed tomography scan of the chest. The 10 patients showed normal spirometry and lung volumes with severe compromise of gas exchange. Normal lung volumes do not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.

  5. The impact of aerosolized mucolytic agents on the airflow resistance of bacterial filters used in mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Han-Chung Hu

    2015-08-01

    Conclusion: This study demonstrated the aerosolized mucolytic agents could increase the pressure drop of the bacterial filters during mechanical ventilation. The pressure drop of the bacterial filters was higher with 10% acetylcysteine. It is critical to continuously monitor the expiration resistance, auto-positive end-expiratory pressure, and ventilator output waveform when aerosolized 10% acetylcysteine was used in mechanical ventilation patients.

  6. Mechanical ventilation with lower tidal volumes and positive end-expiratory pressure prevents pulmonary inflammation in patients without preexisting lung injury

    NARCIS (Netherlands)

    Wolthuis, Esther K.; Choi, Goda; Dessing, Mark C.; Bresser, Paul; Lutter, Rene; Dzoljic, Misa; van der Poll, Tom; Vroom, Margreeth B.; Hollmann, Markus; Schultz, Marcus J.

    2008-01-01

    Background: Mechanical ventilation with high tidal volumes aggravates lung injury in patients with acute lung injury or acute respiratory distress syndrome. The authors sought to determine the effects of short-term mechanical ventilation on local inflammatory responses in patients without

  7. Proportion of false-positive lesions at interim and end-of-treatment FDG-PET in lymphoma as determined by histology: Systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A., E-mail: h.j.a.adams@gmail.com; Kwee, Thomas C.

    2016-11-15

    Purpose: To systematically review and meta-analyze the proportion of false-positive lesions at interim and end-of-treatment {sup 18}F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in lymphoma using biopsy as reference standard. Materials and methods: Medline was searched for original studies. Methodological quality of included studies was evaluated, and results were meta-analytically summarized using random effects (in case of interstudy heterogeneity [I{sup 2} ≤ 50%]) or fixed effects (in case of no interstudy heterogeneity [I{sup 2} > 50%]). Results: Eleven studies, comprising 139 patients who underwent biopsy of an FDG-avid lesion during or after completion of antilymphoma treatment, were included. Overall methodological quality was moderate. The proportion of false-positive results among all biopsied FDG-avid lesions at PET performed during of after completion of treatment ranged between 7.7% and 90.5% (the vast majority was due to inflammatory changes), with a weighted summary proportion (random effects, I{sup 2} = 75.7%) of 55.7% (95% confidence interval [CI]: 32.6–76.6%). There were no available studies on interim FDG-PET in Hodgkin lymphoma. The pooled summary false-positive proportions were 83.0% (95% CI: 72.0%–90.2%) for interim FDG-PET in non-Hodgkin lymphoma (fixed effects, I{sup 2} = 27.7%), 23.1% (95% CI: 4.7%–64.5%) for end-of-treatment FDG-PET in Hodgkin lymphoma (random effects; I{sup 2} = 67.1%), and 31.5% (95% CI: 3.9%–83.9%) for end-of-treatment FDG-PET in non-Hodgkin lymphoma (random effects, I{sup 2} = 68.3%). Conclusion: Both interim and end-of-treatment FDG-PET scans in patients with lymphoma suffer from a very high number of false-positive FDG-avid lesions. This finding, in combination with the previously reported high number of false-negative FGD-PET scans for residual disease detection, suggests that the role of interim and end-of-treatment FDG-PET should be reconsidered.

  8. Numerical study on the selective excitation of Helmholtz-Gauss beams in end-pumped solid-state digital lasers with the control of the laser gain transverse position provided by off-axis end pumping

    Science.gov (United States)

    Tsai, Ko-Fan; Chu, Shu-Chun

    2018-03-01

    This study proposes a complete and unified method for selective excitation of any specified nearly nondiffracting Helmholtz-Gauss (HzG) beam in end-pumped solid-state digital lasers. Four types of the HzG beams: cosine-Gauss beams, Bessel-Gauss beams, Mathieu-Gauss beams, and, in particular, parabolic-Gauss beams are successfully demonstrated to be generated with the proposed methods. To the best of the authors’ knowledge, parabolic-Gauss beams have not yet been directly generated from any kind of laser system. The numerical results of this study show that one can successfully achieve any lasing HzG beams directly from the solid-state digital lasers with only added control of the laser gain transverse position provided by off-axis end pumping. This study also presents a practical digital laser set-up for easily manipulating off-axis pumping in order to achieve the control of the laser gain transverse gain position in digital lasers. The reported results in this study provide advancement of digital lasers in dynamically generating nondiffracting beams. The control of the digital laser cavity gain position creates the possibility of achieving real-time selection of more laser modes in digital lasers, and it is worth further investigation in the future.

  9. Neonatal Pneumothorax Pressures Surpass Higher Threshold in Lung Recruitment Maneuvers: An In Vivo Interventional Study.

    Science.gov (United States)

    González-Pizarro, Patricio; García-Fernández, Javier; Canfrán, Susana; Gilsanz, Fernando

    2016-02-01

    Causing pneumothorax is one of the main concerns of lung recruitment maneuvers in pediatric patients, especially newborns. Therefore, these maneuvers are not performed routinely during anesthesia. Our objective was to determine the pressures that cause pneumothorax in healthy newborns by a prospective experimental study of 10 newborn piglets (pneumothorax. Animals under anesthesia and bilateral chest tube catheterization were randomly allocated to 2 groups: one with PEEP and fixed inspiratory driving pressure of 15 cm H2O (PEEP group) and the second one with PEEP = 0 cm H2O and non-fixed inspiratory driving pressure (zero PEEP group). In both groups, the ventilation mode was pressure-controlled, and PIP was raised at 2-min intervals, with steps of 5 cm H2O until air leak was observed through the chest tubes. The PEEP group raised PIP through 5-cm H2O PEEP increments, and the zero PEEP group raised PIP through 5-cm H2O inspiratory driving pressure increments. Pneumothorax was observed with a PIP of 90.5 ± 15.7 cm H2O with no statistically significant differences between the PEEP group (92 ± 14.8 cm H2O) and the zero PEEP group (89 ± 18.2 cm H2O). The zero PEEP group had hypotension, with a PIP of 35 cm H2O; the PEEP group had hypotension, with a PIP of 60 cm H2O (P = .01). The zero PEEP group presented bradycardia, with PIP of 40 cm H2O; the PEEP group presented bradycardia, with PIP of 70 cm H2O (P = .002). Performing recruitment maneuvers in newborns without lung disease is a safe procedure in terms of pneumothorax. Pneumothorax does not seem to occur in the clinically relevant PIPs of pneumothorax PIP in poorly compliant lungs. Copyright © 2016 by Daedalus Enterprises.

  10. The effect of positive expiratory pressure (PEP) therapy on symptoms, quality of life and incidence of re-exacerbation in patients with acute exacerbations of chronic obstructive pulmonary disease: a multicentre, randomised controlled trial.

    Science.gov (United States)

    Osadnik, Christian R; McDonald, Christine F; Miller, Belinda R; Hill, Catherine J; Tarrant, Ben; Steward, Ranjana; Chao, Caroline; Stodden, Nicole; Oliveira, Cristino C; Gagliardi, Nadia; Holland, Anne E

    2014-02-01

    Positive expiratory pressure (PEP) is a technique used to enhance sputum clearance during acute exacerbations of chronic obstructive pulmonary disease (AECOPD). The impact of PEP therapy during acute exacerbations on clinically important outcomes is not clear. This study sought to determine the effect of PEP therapy on symptoms, quality of life and future exacerbations in patients with AECOPD. 90 inpatients (58 men; mean age 68.6 years, FEV(1) 40.8% predicted) with AECOPD and sputum expectoration were randomised to receive usual care (including physical exercise)±PEP therapy. The Breathlessness, Cough and Sputum Scale (BCSS), St George's Respiratory Questionnaire (SGRQ) and BODE index (Body mass index, airflow Obstruction, Dyspnoea, Exercise tolerance) were measured at discharge, 8 weeks and 6 months following discharge, and analysed via linear mixed models. Exacerbations and hospitalisations were recorded using home diaries. There were no significant between-group differences over time for BCSS score [mean (SE) at discharge 5.2 (0.4) vs 5.0 (0.4) for PEP and control group, respectively; p=0.978] or SGRQ total score [41.6 (2.6) vs 40.8 (2.8) at 8 weeks, p=0.872]. Dyspnoea improved more rapidly in the PEP group over the first 8 weeks (p=0.006), however these benefits were not observed at 6 months. Exacerbations (p=0.986) and hospitalisations (p=0.359) did not differ between groups. We found no evidence that PEP therapy during AECOPD improves important short-term or long-term outcomes. There does not appear to be a routine role for PEP therapy in the management of such individuals.

  11. False Position, Double False Position and Cramer's Rule

    Science.gov (United States)

    Boman, Eugene

    2009-01-01

    We state and prove the methods of False Position (Regula Falsa) and Double False Position (Regula Duorum Falsorum). The history of both is traced from ancient Egypt and China through the work of Fibonacci, ending with a connection between Double False Position and Cramer's Rule.

  12. Effect of driving pressure on mortality in ARDS patients during lung protective mechanical ventilation in two randomized controlled trials.

    Science.gov (United States)

    Guérin, Claude; Papazian, Laurent; Reignier, Jean; Ayzac, Louis; Loundou, Anderson; Forel, Jean-Marie

    2016-11-29

    Driving pressure (ΔPrs) across the respiratory system is suggested as the strongest predictor of hospital mortality in patients with acute respiratory distress syndrome (ARDS). We wonder whether this result is related to the range of tidal volume (V T ). Therefore, we investigated ΔPrs in two trials in which strict lung-protective mechanical ventilation was applied in ARDS. Our working hypothesis was that ΔPrs is a risk factor for mortality just like compliance (Crs) or plateau pressure (Pplat,rs) of the respiratory system. We performed secondary analysis of data from 787 ARDS patients enrolled in two independent randomized controlled trials evaluating distinct adjunctive techniques while they were ventilated as in the low V T arm of the ARDSnet trial. For this study, we used V T , positive end-expiratory pressure (PEEP), Pplat,rs, Crs, ΔPrs, and respiratory rate recorded 24 hours after randomization, and compared them between survivors and nonsurvivors at day 90. Patients were followed for 90 days after inclusion. Cox proportional hazard modeling was used for mortality at day 90. If colinearity between ΔPrs, Crs, and Pplat,rs was verified, specific Cox models were used for each of them. Both trials enrolled 805 patients of whom 787 had day-1 data available, and 533 of these survived. In the univariate analysis, ΔPrs averaged 13.7 ± 3.7 and 12.8 ± 3.7 cmH 2 O (P = 0.002) in nonsurvivors and survivors, respectively. Colinearity between ΔPrs, Crs and Pplat,rs, which was expected as these variables are mathematically coupled, was statistically significant. Hazard ratios from the Cox models for day-90 mortality were 1.05 (1.02-1.08) (P = 0.005), 1.05 (1.01-1.08) (P = 0.008) and 0.985 (0.972-0.985) (P = 0.029) for ΔPrs, Pplat,rs and Crs, respectively. PEEP and V T were not associated with death in any model. When ventilating patients with low V T , ΔPrs is a risk factor for death in ARDS patients, as is Pplat,rs or Crs. As our data

  13. End-to-end self-assembly of gold nanorods in isopropanol solution: experimental and theoretical studies

    Energy Technology Data Exchange (ETDEWEB)

    Gordel, M., E-mail: marta.gordel@pwr.edu.pl [Wrocław University of Technology, Advanced Materials Engineering and Modelling Group, Faculty of Chemistry (Poland); Piela, K., E-mail: katarzyna.piela@pwr.edu.pl [Wrocław University of Technology, Department of Physical and Quantum Chemistry (Poland); Kołkowski, R. [Wrocław University of Technology, Advanced Materials Engineering and Modelling Group, Faculty of Chemistry (Poland); Koźlecki, T. [Wrocław University of Technology, Department of Chemical Engineering, Faculty of Chemistry (Poland); Buckle, M. [CNRS, École Normale Supérieure de Cachan, Laboratoire de Biologie et Pharmacologie Appliquée (France); Samoć, M. [Wrocław University of Technology, Advanced Materials Engineering and Modelling Group, Faculty of Chemistry (Poland)

    2015-12-15

    We describe here a modification of properties of colloidal gold nanorods (NRs) resulting from the chemical treatment used to carry out their transfer into isopropanol (IPA) solution. The NRs acquire a tendency to attach one to another by their ends (end-to-end assembly). We focus on the investigation of the change in position and shape of the longitudinal surface plasmon (l-SPR) band after self-assembly. The experimental results are supported by a theoretical calculation, which rationalizes the dramatic change in optical properties when the NRs are positioned end-to-end at short distances. The detailed spectroscopic characterization performed at the consecutive stages of transfer of the NRs from water into IPA solution revealed the features of the interaction between the polymers used as ligands and their contribution to the final stage, when the NRs were dispersed in IPA solution. The efficient method of aligning the NRs detailed here may facilitate applications of the self-assembled NRs as building blocks for optical materials and biological sensing.Graphical Abstract.

  14. Quantitative assessment of cross-sectional area of small pulmonary vessels in patients with COPD using inspiratory and expiratory MDCT

    International Nuclear Information System (INIS)

    Matsuura, Yukiko; Kawata, Naoko; Yanagawa, Noriyuki; Sugiura, Toshihiko; Sakurai, Yoriko; Sato, Misuzu; Iesato, Ken; Terada, Jiro; Sakao, Seiichiro; Tada, Yuji; Tanabe, Nobuhiro; Suzuki, Yoichi; Tatsumi, Koichiro

    2013-01-01

    Objectives: Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has been defined whether the structural changes of pulmonary vessels detected by paired inspiratory and expiratory CT scans are associated with emphysematous changes. We quantified the CSA and low attenuation area (LAA) and evaluated the changes in these parameters in the inspiratory and expiratory phases. Materials and methods: Fifty consecutive non-COPD smokers and COPD patients were subjected to multi detector-row CT and the percentage of vessels with a CSA less than 5 mm 2 as well as the percentage LAA for total lung area (%CSA < 5, %LAA, respectively) were calculated. Results: The %CSA < 5 correlated negatively with %LAA. The %CSA < 5 was lower in COPD patients with emphysema as compared with non-COPD smokers and COPD patients with or without mild emphysema. In addition, the %CSA < 5 was lower in the no/mild emphysema subgroup as compared with non-COPD smokers. The respiratory phase change of %CSA < 5 in COPD patients was greater than that in non-COPD smokers. Conclusion: The percentage of small pulmonary vessels decreased as emphysematous changes increase, and this decrease was observed even in patients with no/mild emphysema. Furthermore, respiratory phase changes in CSA were higher in COPD patients than in non-COPD smokers

  15. Transport of expiratory droplets in an aircraft cabin.

    Science.gov (United States)

    Gupta, Jitendra K; Lin, Chao-Hsin; Chen, Qingyan

    2011-02-01

    The droplets exhaled by an index patient with infectious disease such as influenza or tuberculosis may be the carriers of contagious agents. Indoor environments such as the airliner cabins may be susceptible to infection from such airborne contagious agents. The present investigation computed the transport of the droplets exhaled by the index patient seated in the middle of a seven-row, twin-aisle, fully occupied cabin using the CFD simulations. The droplets exhaled were from a single cough, a single breath, and a 15-s talk of the index patient. The expiratory droplets were tracked by using Lagrangian method, and their evaporation was modeled. It was found that the bulk airflow pattern in the cabin played the most important role on the droplet transport. The droplets were contained in the row before, at, and after the index patient within 30 s and dispersed uniformly to all the seven rows in 4 minutes. The total airborne droplet fraction reduced to 48, 32, 20, and 12% after they entered the cabin for 1, 2, 3, and 4 min, respectively, because of the ventilation from the environmental control system. It is critical to predict the risk of airborne infection to take appropriate measures to control and mitigate the risk. Most of the studies in past either assume a homogenous distribution of contaminants or use steady-state conditions. The present study instead provides information on the transient movement of the droplets exhaled by an index passenger in an aircraft cabin. These droplets may contain active contagious agents and can be potent enough to cause infection. The findings can be used by medical professionals to estimate the spatial and temporal distribution of risk of infection to various passengers in the cabin. © 2010 John Wiley & Sons A/S.

  16. Comparação entre inspirometria de incentivo e pressão positiva expiratória na função pulmonar após cirurgia bariátrica Comparison between incentive spirometry and expiratory positive airway pressure on pulmonary function after bariatric surgery

    Directory of Open Access Journals (Sweden)

    Marcela C. Barbalho-Moulim

    2009-06-01

    Full Text Available O objetivo deste estudo foi comparar o efeito da pressão positiva expiratória (EPAP, na sigla em inglês e da inspirometria de incentivo a fluxo sobre a função pulmonar após o bypass gástrico em Y de Roux por videolaparoscopia. Participaram 28 mulheres, não-tabagistas e não-pneumopatas, com índice de massa corporal entre 35 e 50 kg/m², submetidas à cirurgia bariátrica. Todas foram avaliadas por espirometria, cirtometria toracoabdominal e quanto à mobilidade diafragmática no pré e segundo dia de pós-operatório (o tempo de internação foi de 2 dias. Foram divididas em dois grupos, GI - grupo inspirômetro (n=13 e GE, grupo EPAP (n=15. A fisioterapia foi iniciada no dia da cirurgia, cada técnica, inspirometria ou EPAP, com duração de 15 minutos; a fisioterapia motora foi padronizada para ambos os grupos. No pós-operatório, houve redução similar nos dois grupos das variáveis: capacidade vital, volume de reserva inspiratório, capacidade vital forçada e ventilação voluntária máxima. Não houve alteração nos valores do volume corrente no GI e volume de reserva expiratório no GE. A mobilidade diafragmática e a mobilidade toracoabdominal foram menos prejudicadas no GI. No pós-operatório da cirurgia bariátrica por videolaparoscopia, a inspirometria de incentivo a fluxo exerceu melhores efeitos na manutenção do volume corente, na mobilidade diafragmática e toracoabdominal, enquanto a EPAP foi mais eficaz no restabelecimento do volume de reserva expiratório.The aim of this study was to compare the effect of expiratory positive airway pressure (EPAP and flow-oriented incentive spirometry on pulmonary function after laparoscopic Roux-en-Y gastric bypass surgery. Twenty-eight non-smoking women, with no lung disease and body mass index of 35 to 50 kg/m², undergoing laparoscopic gastric bypass surgery (hospitalized for two days were assessed by spirometry, thoracoabdominal cirtometry and as to diaphragmatic motion

  17. Learning-based position control of a closed-kinematic chain robot end-effector

    Science.gov (United States)

    Nguyen, Charles C.; Zhou, Zhen-Lei

    1990-01-01

    A trajectory control scheme whose design is based on learning theory, for a six-degree-of-freedom (DOF) robot end-effector built to study robotic assembly of NASA hardwares in space is presented. The control scheme consists of two control systems: the feedback control system and the learning control system. The feedback control system is designed using the concept of linearization about a selected operating point, and the method of pole placement so that the closed-loop linearized system is stabilized. The learning control scheme consisting of PD-type learning controllers, provides additional inputs to improve the end-effector performance after each trial. Experimental studies performed on a 2 DOF end-effector built at CUA, for three tracking cases show that actual trajectories approach desired trajectories as the number of trials increases. The tracking errors are substantially reduced after only five trials.

  18. Acute lung injury and acute respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    Ragaller Maximillian

    2010-01-01

    Full Text Available Every year, more information accumulates about the possibility of treating patients with acute lung injury or acute respiratory distress syndrome with specially designed mechanical ventilation strategies. Ventilator modes, positive end-expiratory pressure settings, and recruitment maneuvers play a major role in these strategies. However, what can we take from these experimental and clinical data to the clinical practice? In this article, we discuss substantial options of mechanical ventilation together with some adjunctive therapeutic measures, such as prone positioning and inhalation of nitric oxide.

  19. Setting ventilation parameters guided by electrical impedance tomography in an animal trial of acute respiratory distress syndrome

    Science.gov (United States)

    Czaplik, Michael; Biener, Ingeborg; Leonhardt, Steffen; Rossaint, Rolf

    2014-03-01

    Since mechanical ventilation can cause harm to lung tissue it should be as protective as possible. Whereas numerous options exist to set ventilator parameters, an adequate monitoring is lacking up to date. The Electrical Impedance Tomography (EIT) provides a non-invasive visualization of ventilation which is relatively easy to apply and commercially available. Although there are a number of published measures and parameters derived from EIT, it is not clear how to use EIT to improve clinical outcome of e.g. patients suffering from acute respiratory distress syndrome (ARDS), a severe disease with a high mortality rate. On the one hand, parameters should be easy to obtain, on the other hand clinical algorithms should consider them to optimize ventilator settings. The so called Global inhomogeneity (GI) index bases on the fact that ARDS is characterized by an inhomogeneous injury pattern. By applying positive endexpiratory pressures (PEEP), homogeneity should be attained. In this study, ARDS was induced by a double hit procedure in six pigs. They were randomly assigned to either the EIT or the control group. Whereas in the control group the ARDS network table was used to set the PEEP according to the current inspiratory oxygen fraction, in the EIT group the GI index was calculated during a decremental PEEP trial. PEEP was kept when GI index was lowest. Interestingly, PEEP was significantly higher in the EIT group. Additionally, two of these animals died ahead of the schedule. Obviously, not only homogeneity of ventilation distribution matters but also limitation of over-distension.

  20. Effect of bedding control on amount of house dust mite allergens, asthma symptoms, and peak expiratory flow rate.

    Science.gov (United States)

    Lee, Inn-Sook

    2003-04-30

    This quasi-experimental study was designed to investigate the effect of bedding control on the amount of house dust mite (HDM) allergens, asthma symptoms, and peak expiratory flow rate (PEFR) in asthmatics sensitive to HDMs. The subjects in the study were drawn from patients receiving treatment at the allergy clinics of three university-affiliated hospitals in Seoul. Forty-two patients without prior practice of the bedding control used in this study were selected. They commonly showed bronchial asthma caused by HDMs, and exhibited strong positive points (more than 3 points) in skin prick test (D. farinae, D. pteronyssinus), and positive response in both fluoro-allergosorbent test (FAST), and PC20 methacholine test. Of the subjects, alternatively, 22 were assigned to the experimental group and 20 to control group. Bedding control consisted of the use of outer cotton covers, boiling them for 10 minutes fortnightly, and disinfecting bedding by sunlight fortnightly. The experimental group was under bedding control for 4 weeks. The data were collected from October 2000 to January 2001. The results were as follows: 1. After bedding control, the total amount of HDM allergens decreased significantly in the experimental group. However there was no significant difference in the decrease of the amount of HDM allergens between the two groups. 2. Of the asthma symptoms, there was significant difference only in the decrease of the frequency of dyspnea, and in the increase of sleeping disturbance between the two groups after bedding control. 3. After bedding control, PEFR increased in the experimental group whereas it decreased in the control group. However, neither change was significant. The above findings indicate that bedding control improved several asthma symptoms in asthmatics sensitive to HDMs. Accordingly, we suggest that bedding control is adopted as a useful nursing intervention in the field.

  1. Peak expiratory flow rate (PEFR) among Nuclear Fuel Complex (NFC) employees

    International Nuclear Information System (INIS)

    Vijay Rao, J.; Venkaiah, K.; Mohan Rao, N.

    2010-01-01

    At Nuclear Fuel Complex (NFC), employees are exposed to ammonia, hydrofluoric acid, acetone, etc., which are respiratory toxicants and inhalation of these pollutants may produce irritation and obstruction in airways. Due to nature of their occupation, tradesman working in plants are having longer duration of exposure (LDE) and others, such as supervisors, scientific officers, helpers, etc., that occasionally visit plants are having shorter duration of exposure (SDE) to these pollutants. The peak expiratory flow rate (PEFR) is an index to diagnose obstruction in larger airways and this is metered with mini peak flow meter among 835 NFC employees. Using ANOVA test, PEFR value was compared according to age and smoking. The value was compared between LDE and SDE employees according to smoking and duration of employment. The multiple regression equation for prediction of PEFR was developed. Age, smokers and higher duration of LDE employees demonstrated significantly lower PEFR value. In comparison to 10 year duration, 30 and above year duration of employment, LDE employees showed a higher decline in PEFR, that is 95 L (17.6%) and in SDE employees, that is 41L (7.8%). This may be due to longer duration of employment of LD employees smoking prevention and follow up study is suggested. (author)

  2. Evaluation of image quality and patient safety: paired inspiratory and expiratory MDCT assessment of tracheobronchomalacia in paediatric patients under general anaesthesia with breath-hold technique

    International Nuclear Information System (INIS)

    Lee, Edward Y.; Bastos, Maria d' Almeida; Stark, Cynthia; Carrier, Maureen; Zurakowski, David; Mason, Keira P.

    2012-01-01

    The purpose of our investigation was to evaluate image quality and patient safety in infants and young children who required general anaesthesia with breath-hold technique for paired inspiratory and expiratory multidetector CT (MDCT) assessment of tracheobronchomalacia (TBM). Our hospital's institutional review board approved the review of radiological and clinical data of a consecutive series of 20 paediatric patients who underwent MDCT under general anaesthesia with breath-hold technique for evaluation of TBM from May 2006 to December 2008. For each MDCT study, two fellowship-trained paediatric radiologists reviewed the inspiratory and expiratory MDCT images in an independent, randomised and blinded fashion for the presence of motion artefact at three anatomic levels (upper, middle and lower central airways). The clinical history and anaesthesia outcome, including the occurrence of any adverse events during or following the MDCT examinations until discharge, were also reviewed and recorded. The study population consisted of 20 infants and young children (13 boys/seven girls, mean age 1.7 ± 1.4 years, age range 11 days to 4 years). The imaging quality of all 20 MDCT studies was diagnostic with no motion artefact in 16 studies (80%) and minimal motion artefact in the remaining four studies (20%). Minor adverse events occurred in three patients (15%) that included one patient (5%) with a brief (<60 s) oxygen desaturation during MDCT study, which resolved with oxygen, and two patients (5%) with either a brief (<60 s) oxygen desaturation (n = 1, 5%) or cough (n = 1, 5%) during recovery period, which were completely resolved with oxygen and dexamethasone, respectively. Diagnostic quality paired inspiratory and expiratory MDCT imaging with breath-hold technique can be safely performed in infants and young children under general anaesthesia for evaluation of TBM.

  3. Quantitative assessment of cross-sectional area of small pulmonary vessels in patients with COPD using inspiratory and expiratory MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Yanagawa, Noriyuki, E-mail: yanagawa@ho.chiba-u.ac.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sakurai, Yoriko, E-mail: yoliri@nifty.com [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sato, Misuzu, E-mail: mis_misuzu@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Iesato, Ken, E-mail: iesato_k@yahoo.co.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Terada, Jiro, E-mail: jirotera@chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Suzuki, Yoichi, E-mail: ysuzuki@faculty.chiba-u.jp [Department of public Health, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan); Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp [Department of Respirology, Graduate School of Medicine, Chiba University, Chiba 260-8670 Japan (Japan)

    2013-10-01

    Objectives: Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has been defined whether the structural changes of pulmonary vessels detected by paired inspiratory and expiratory CT scans are associated with emphysematous changes. We quantified the CSA and low attenuation area (LAA) and evaluated the changes in these parameters in the inspiratory and expiratory phases. Materials and methods: Fifty consecutive non-COPD smokers and COPD patients were subjected to multi detector-row CT and the percentage of vessels with a CSA less than 5 mm{sup 2} as well as the percentage LAA for total lung area (%CSA < 5, %LAA, respectively) were calculated. Results: The %CSA < 5 correlated negatively with %LAA. The %CSA < 5 was lower in COPD patients with emphysema as compared with non-COPD smokers and COPD patients with or without mild emphysema. In addition, the %CSA < 5 was lower in the no/mild emphysema subgroup as compared with non-COPD smokers. The respiratory phase change of %CSA < 5 in COPD patients was greater than that in non-COPD smokers. Conclusion: The percentage of small pulmonary vessels decreased as emphysematous changes increase, and this decrease was observed even in patients with no/mild emphysema. Furthermore, respiratory phase changes in CSA were higher in COPD patients than in non-COPD smokers.

  4. The effect of low dose rocuronium on globe position, muscle relaxation and ventilation in dogs: a clinical study.

    Science.gov (United States)

    Auer, Ulrike; Mosing, Martina; Moens, Yves P S

    2007-01-01

    The purpose of this study was to evaluate globe position, muscle relaxation and changes in ventilatory parameters after intravenous administration of 0.1 mg/kg rocuronium. Prospective clinical study. Sixteen dogs of different breeds, with a body weight of 22.1 +/- 13 kg and age of 5.6 +/- 2.8 years (mean +/- SD), were anesthetized for a short ophthalmic examination requiring central position of the globe. All dogs were premedicated with 0.005 mg/kg medetomidine and 0.1 mg/kg methadone IV. Anesthesia was induced with propofol to effect and maintained with 10 mg/kg/h propofol by continuous rate infusion. Following endotracheal intubation all dogs breathed 100% oxygen via an anesthetic circle system. Neuromuscular function was assessed with an acceleromyograph (TOF-Guard, Organon Teknika NV, Turnhout, Belgium) and by stimulation of the nervus peroneus superficialis. The ventilation parameters were measured using spirometry and capnography. After baseline measurements 0.1 mg/kg rocuronium was administered IV. Minute volume (MV), tidal volume (Vt), respiratory rate (RR), end expiratory carbon dioxide concentration (PE'CO(2)) and maximal depression of the response of the first twitch (T1) of train-of-four (TOF) stimulation and train-of-four ratio (TOFR) was measured. The change in the position of the globe was recorded. T1 decreased to 61 +/- 18% and the TOF ratio to 45 +/- 21% of baseline values. Both parameters returned to baseline after 9 min. There was no significant reduction in MV, TV and RR and no increase in PE'CO(2). The globe rotated to a central position of 45 +/- 7.7 s after administration of rocuronium and remained there for 23 +/- 10.8 min in all dogs. Rocuronium administered intravenously at a dose of 0.1 mg/kg to dogs causes a central position of the globe but minimal impairment of ventilation parameters.

  5. Peak expiratory flow rate in healthy rural school going children (5-16 years) of bellur region for construction of nomogram.

    Science.gov (United States)

    Cb, Manjunath; Sc, Kotinatot; Babu, Manjunatha

    2013-12-01

    Peak Expiratory Flow Rate (PEFR) recording is an essential measure in the management and evaluation of asthmatic children.It is helpful in monitoring disease progression and response to treatment. The PEFR can be measured by a simple instrument-peak expiratory flow meter. To construct nomogram of PEFR in healthy rural school going children from Mandya district of Karnataka state, India and to use these nomograms for comparison with that of children with obstructive lung diseases for this region. The study was conducted on Healthy rural school going children, both boys and girls between the age group of 5-16 years. For the determination of PEFR we used Mini Wright Peak Flow Meter. At three time measurement, the highest value of PEFR was recorded. Formula for prediction of PEFR was estimated by linear regression analysis after the correlation of PEFR with age and height for both boys and girls. PEFR was measured in 1028 children aged 5 to 16 years by using Wright's mini peak flow meter. Prediction equations were derived for PEFR with height in boys and girls. Normograms were plotted based on the observed values of PEFR in the study population. Significant linear correlation was seen of PEFR with height in boys (paffected by regional, environmental and anthropometric factors. Hence, it is necessary to have regional reference values for children. Among different factors affecting PEFR, height correlates better with PEFR than weight and sex. Hence nomograms constructed can be used for this region.

  6. A Simple Measure to Assess Hyperinflation and Air Trapping: 1-Forced Expiratory Volume in Three Second / Forced Vital Capacity

    Directory of Open Access Journals (Sweden)

    Sermin Börekçi

    2017-04-01

    Full Text Available Background: Several recent studies have suggested that 1 minus-forced expiratory volume expired in 3 seconds / forced vital capacity (1-FEV3/FVC may be an indicator of distal airway obstruction and a promising measure to evaluate small airways dysfunction. Aims: To investigate the associations of 1-FEV3/FVC with the spirometric measures and lung volumes that assess small airways dysfunction and reflects hyperinflation and air trapping. Study Design: Retrospective cross-sectional study. Methods: Retrospective assessment of a total of 1110 cases who underwent body plethysmographic lung volume estimations between a time span from 2005 to 2012. Patients were assigned into two groups: firstly by FEV1/FVC (FEV1/FVC <70% vs. FEV1/FVC ≥70%; secondly by FEV3/FVC < lower limits of normal (LLN (FEV3/FVC < LLN vs. FEV3/FVC ≥ LLN. Spirometric indices and lung volumes measured by whole-body plethysmography were compared in groups. Also the correlation of spirometric indices with measured lung volumes were assessed in the whole-study population and in subgroups stratified according to FEV1/FVC and FEV3/FVC. Results: Six hundred seven (54.7% were male and 503 (45.3% were female, with a mean age of 52.5±15.6 years. Mean FEV3/FVC and 1-FEV3/FVC were 87.05%, 12.95%, respectively. The mean 1-FEV3/FVC was 4.9% in the FEV1/FVC ≥70% group (n=644 vs. 24.1% in the FEV1/FVC <70% group (n=466. A positive correlation was found between 1-FEV3/FVC and residual volume (r=0.70; p<0.0001, functional residual capacity-pleth (r=0.61; p<0.0001, and total lung capacity (r=0.47; p<0.0001. 1-FEV3/FVC was negatively correlated with forced expiratory flow25-75 (r=−0.84; p<0.0001. The upper limit of 95% confidence interval for 1-FEV3/FVC was 13.7%. 1-FEV3/FVC showed significant correlations with parameters of air trapping and hyperinflation measured by whole-body plethysmography. Importantly, these correlations were higher in study participants with FEV1/FVC <70% or FEV3/FVC

  7. Prediction of Spirometric Forced Expiratory Volume (FEV1) Data Using Support Vector Regression

    Science.gov (United States)

    Kavitha, A.; Sujatha, C. M.; Ramakrishnan, S.

    2010-01-01

    In this work, prediction of forced expiratory volume in 1 second (FEV1) in pulmonary function test is carried out using the spirometer and support vector regression analysis. Pulmonary function data are measured with flow volume spirometer from volunteers (N=175) using a standard data acquisition protocol. The acquired data are then used to predict FEV1. Support vector machines with polynomial kernel function with four different orders were employed to predict the values of FEV1. The performance is evaluated by computing the average prediction accuracy for normal and abnormal cases. Results show that support vector machines are capable of predicting FEV1 in both normal and abnormal cases and the average prediction accuracy for normal subjects was higher than that of abnormal subjects. Accuracy in prediction was found to be high for a regularization constant of C=10. Since FEV1 is the most significant parameter in the analysis of spirometric data, it appears that this method of assessment is useful in diagnosing the pulmonary abnormalities with incomplete data and data with poor recording.

  8. Expiratory CT in cigarette smokers: correlation between areas of decreased lung attenuation, pulmonary function tests and smoking history

    Energy Technology Data Exchange (ETDEWEB)

    Verschakelen, J.A.; Scheinbaum, K.; Bogaert, J.; Baert, A.L. [Department of Radiology, University Hospitals, Leuven (Belgium); Demedts, M.; Lacquet, L.L. [Department of Pneumology, University Hospitals, Leuven (Belgium)

    1998-10-01

    The aim of this study was to determine the correlation between cigarette-smoke-related bronchial disease and air trapping as assessed by expiratory high-resolution CT (HRCT) scans. Thirty healthy subjects (11 non-smokers, 7 ex-smokers for > 2 years, 12 current smokers; age range 35-55 years) with a smoking history between 0 and 28.5 pack-years underwent pulmonary function tests (PFT) and HRCT in inspiration and expiration in supine and prone position. The extent of air trapping was scored in ventral and dorsal aspects of the upper, middle and lower lung portions. In 24 subjects (7 non-smokers, 7 ex-smokers, 10 current smokers) areas of focal air trapping were found, and were present significantly more often in dependent lung portions (p < 0.05) compared with non-dependent portions. No significant differences were found between apical and basal lung zones. Scores of focal air trapping were not significantly different between smokers and ex-smokers, but were significantly lower (p < 0.05) in non-smokers and showed a significant (p < 0.0005) correlation with pack-years. The degree of air trapping was also associated with several lung function tests, especially RV, DLCO, FRC, FEV1 and FEV1/VC. Air trapping is seen in smokers with normal PFT and correlates with the severity of the smoking history, independently of current smoking status. (orig.) (orig.) With 4 figs., 4 tabs., 59 refs.

  9. An experimental randomized study of six different ventilatory modes in a piglet model with normal lungs

    DEFF Research Database (Denmark)

    Nielsen, J B; Sjöstrand, U H; Henneberg, S W

    1991-01-01

    -controlled intermittent positive-pressure ventilation; and SV-20P denotes pressure-controlled intermittent positive-pressure ventilation. With all modes of ventilation a PEEP of 7.5 cm H2O was used. In the abbreviations used, the number denotes the ventilatory frequency in breaths per minute (bpm). HFV indicates that all...

  10. Progress in LAr EndCap Calorimetry: News from the Hadronic EndCap Group.

    CERN Multimedia

    Oram, C.J.

    With module production and testing completed for the Hadronic EndCap calorimeter, the attention of the HEC group is heavily directed towards wheel assembly in building 180. Three of the four HEC wheels are now assembled and rotated, and work is progressing on assembling the final wheel. This year has been a busy year for the installation of components in the EndCap C cryostat: the signal feedthrough installation was completed April 22nd, the pre-sampler shortly thereafter and the Electro-Magnetic EndCap August 13th. This allowed the HEC group to start transferring the HEC wheels from the T6A storage cradle into the cryostat. The operation started in mid-September and has progressed, on or ahead of schedule, since then with the major milestones being: Insertion of 67 ton front HEC wheel October 3rd Insertion of 90 ton rear HEC wheel October 22nd. The wheel alignment has proved to be excellent, with the position of the centre of the front(rear) wheel with respect to the nominal position being displaced b...

  11. Ultra-protective tidal volume: how low should we go?

    OpenAIRE

    Costa, Eduardo LV; Amato, Marcelo BP

    2013-01-01

    Applying tidal volumes of less than 6 mL/kg might improve lung protection in patients with acute respiratory distress syndrome. In a recent article, Retamal and colleagues showed that such a reduction is feasible with conventional mechanical ventilation and leads to less tidal recruitment and overdistension without causing carbon dioxide retention or auto-positive end-expiratory pressure. However, whether the compensatory increase in the respiratory rate blunts the lung protection remains une...

  12. Decreased peak expiratory flow in pediatric passive smokers

    Directory of Open Access Journals (Sweden)

    Fitri Yanti

    2011-08-01

    Full Text Available Background Indonesia ranks fifth among countries with the highest aggregate levels of tobacco consumption in the world. Infants and children exposed to environmental tobacco smoke have increased rates of asthma, respiratory and ear infections, as well as reduced lung function. The effects of tobacco smoke exposure on lung function in children have been reported to be dependent on the source of smoke and the length and dose of exposure. Lung function may also be affected by a child’s gender and asthma status. Objective To compare peak expiratory flow (PEF in pediatric passive smokers to that of children not exposed to second hand smoke, and to define factors that may affect PEF in passive smokers. Methods In August 2009 we conducted a cross-sectional study at an elementary school in the Langkat district. Subjects were aged 6 to 12 years, and divided into two groups: passive smokers and those not exposed to secondhand smoke. Subjects’ PEFs were measured with a Mini-Wright peak flow meter. Measurements were performed in triplicate with the highest value recorded as the PEF. Demographic data including age, sex, weight, height, family income, parental education levels and occupations were obtained through questionnaires. Results Of the 170 participants, 100 were passive smokers and 70 were not exposed to secondhand smoke. Age distribution, weight and height were similar in both groups. We observed a significant difference in PEFs between the group of passive smokers and the group not exposed to secondhand smoke, 211.3 L/minute (SD 61.08 and 242.7 L/minute (SD 77.09, respectively (P < 0.005. The number of years of exposure to smoke (P = 0.079 and the number of cigarettes smoked daily in the household (P = 0.098 did not significantly influence PEF. Conclusion The PEF in pediatric passive smokers was significantly lower than that of children not exposed to secondhand smoke. PEF in passive smokers was not influenced by the number of years of smoke

  13. ERGONOMIC CONSIDERATION OF THE EFFECT OF FLOUR DUST ON PEAK EXPIRATORY FLOW RATE OF BAKERS IN ABEOKUTA, OGUN STATE

    Directory of Open Access Journals (Sweden)

    Adekunle Ibrahim MUSA

    2017-06-01

    Full Text Available Flour dusts are one of the most harmful chemicals in the bakery industries which could lead to serious heart and lung diseases. This study investigated the effect of flour dust on Peak Expiratory Flow Rate of male bakers in Abeokuta, Ogun State, Nigeria with the relationship to the anthropometrical parameters. A total of One hundred Eighty (180 male participants were investigated, where ninety (90 participants were bakers and ninety (90 individuals as control group. The Peak expiratory flow rate (PEFR and anthropometrical parameters of the participant were measured using mini-Wright peak flow meter (PFM 20, OMRON and Detecto PD300MDHR (Cardinal Scale manufacturing company, USA column scale with digital height rod was used to measure body mass [kg] and height (cm respectively. The PEFR and anthropometrical parameters of the bakers and control groups were analysed using descriptive statistics and T-test with SPSS. The results showed that lower PEFR, 182.67 ± 16.34 L/min existed in bakers compared to 287.67 ± 17.02 L/min in the control study. The result also showed that a significant correlation exist between body mass, height and age (P < 0.01, PEFR, height (P < 0.05 and years of exposure (P < 0.01 of the bakers respectively. Furthermore, the results also showed that workers in the dusting and mixing of flour are at a risk of developing related pulmonary function impairment such as asthma. The study concluded that there is need to develop an effective intervention strategy, treatment seeking behaviour through awareness programs to prevent lung impairment diseases among the bakery workers.

  14. Intrathoracic pressure regulation during cardiopulmonary resuscitation: a feasibility case-series.

    Science.gov (United States)

    Segal, Nicolas; Parquette, Brent; Ziehr, Jonathon; Yannopoulos, Demetris; Lindstrom, David

    2013-04-01

    Intrathoracic pressure regulation (IPR) is a novel, noninvasive therapy intended to increase cardiac output and blood pressure in hypotensive states by generating a negative end expiratory pressure of -12 cm H2O between positive pressure ventilations. In this first feasibility case-series, we tested the hypothesis that IPR improves End tidal (ET) CO2 during cardiopulmonary resuscitation (CPR). ETCO2 was used as a surrogate measure for circulation. All patients were treated initially with manual CPR and an impedance threshold device (ITD). When IPR-trained medics arrived on scene the ITD was removed and an IPR device (CirQLATOR™) was attached to the patient's advanced airway (intervention group). The IPR device lowered airway pressures to -9 mmHg after each positive pressure ventilation for the duration of the expiratory phase. ETCO2, was measured using a capnometer incorporated into the defibrillator system (LifePak™). Values are expressed as mean ± SEM. Results were compared using paired and unpaired Student's t test. p values of <0.05 were considered statistically significant. ETCO2 values in 11 patients in the case series were compared pre and during IPR therapy and also compared to 74 patients in the control group not treated with the new IPR device. ETCO2 values increased from an average of 21 ± 1 mmHg immediately before IPR application to an average value of 32 ± 5 mmHg and to a maximum value of 45 ± 5mmHg during IPR treatment (p<0.001). In the control group ETCO2 values did not change significantly. Return of spontaneous circulation (ROSC) rates were 46% (34/74) with standard CPR and ITD versus 73% (8/11) with standard CPR and the IPR device (p<0.001). ETCO2 levels and ROSC rates were significantly higher in the study intervention group. These findings demonstrate that during CPR circulation may be significantly augmented by generation of a negative end expiratory pressure between each breath. Copyright © 2012 Elsevier Ireland Ltd. All rights

  15. Spatiotemporal Aeration and Lung Injury Patterns Are Influenced by the First Inflation Strategy at Birth.

    Science.gov (United States)

    Tingay, David G; Rajapaksa, Anushi; Zonneveld, C Elroy; Black, Don; Perkins, Elizabeth J; Adler, Andy; Grychtol, Bartłomiej; Lavizzari, Anna; Frerichs, Inéz; Zahra, Valerie A; Davis, Peter G

    2016-02-01

    Ineffective aeration during the first inflations at birth creates regional aeration and ventilation defects, initiating injurious pathways. This study aimed to compare a sustained first inflation at birth or dynamic end-expiratory supported recruitment during tidal inflations against ventilation without intentional recruitment on gas exchange, lung mechanics, spatiotemporal regional aeration and tidal ventilation, and regional lung injury in preterm lambs. Lambs (127 ± 2 d gestation), instrumented at birth, were ventilated for 60 minutes from birth with either lung-protective positive pressure ventilation (control) or as per control after either an initial 30 seconds of 40 cm H2O sustained inflation (SI) or an initial stepwise end-expiratory pressure recruitment maneuver during tidal inflations (duration 180 s; open lung ventilation [OLV]). At study completion, molecular markers of lung injury were analyzed. The initial use of an OLV maneuver, but not SI, at birth resulted in improved lung compliance, oxygenation, end-expiratory lung volume, and reduced ventilatory needs compared with control, persisting throughout the study. These changes were due to more uniform inter- and intrasubject gravity-dependent spatiotemporal patterns of aeration (measured using electrical impedance tomography). Spatial distribution of tidal ventilation was more stable after either recruitment maneuver. All strategies caused regional lung injury patterns that mirrored associated regional volume states. Irrespective of strategy, spatiotemporal volume loss was consistently associated with up-regulation of early growth response-1 expression. Our results show that mechanical and molecular consequences of lung aeration at birth are not simply related to rapidity of fluid clearance; they are also related to spatiotemporal pressure-volume interactions within the lung during inflation and deflation.

  16. MDCT assessment of tracheomalacia in symptomatic infants with mediastinal aortic vascular anomalies: preliminary technical experience

    International Nuclear Information System (INIS)

    Lee, Edward Y.; Mason, Keira P.; Zurakowski, David; Waltz, David A.; Ralph, Amy; Riaz, Farhana; Boiselle, Phillip M.

    2008-01-01

    Mediastinal aortic vascular anomalies are relatively common causes of extrinsic central airway narrowing in infants with respiratory symptoms. Surgical correction of mediastinal aortic vascular anomalies alone might not adequately treat airway symptoms if extrinsic narrowing is accompanied by intrinsic tracheomalacia (TM), a condition that escapes detection on routine end-inspiratory imaging. Paired inspiratory-expiratory multidetector CT (MDCT) has the potential to facilitate early diagnosis and timely management of TM in symptomatic infants with mediastinal aortic vascular anomalies. To assess the technical feasibility of paired inspiratory-expiratory MDCT for evaluating TM among symptomatic infants with mediastinal aortic vascular anomalies. The study group consisted of five consecutive symptomatic infants (four male, one female; mean age 4.1 months, age range 2 weeks to 6 months) with mediastinal aortic vascular anomalies who were referred for paired inspiratory-expiratory MDCT during a 22-month period. CT angiography was concurrently performed during the end-inspiration phase of the study. Two pediatric radiologists in consensus reviewed all CT images in a randomized and blinded fashion. The end-inspiration and end-expiration CT images were reviewed for the presence and severity of tracheal narrowing. TM was defined as ≥50% reduction in tracheal cross-sectional luminal area between end-inspiration and end-expiration. The presence of TM was compared to the bronchoscopy results when available (n = 4). Paired inspiratory-expiratory MDCT was technically successful in all five patients. Mediastinal aortic vascular anomalies included a right aortic arch with an aberrant left subclavian artery (n = 2), innominate artery compression (n = 2), and a left aortic arch with an aberrant right subclavian artery (n 1). Three (60%) of the five patients demonstrated focal TM at the level of mediastinal aortic vascular anomalies. The CT results were concordant with the results

  17. Welding nuclear reactor fuel rod end plugs

    International Nuclear Information System (INIS)

    Yeo, D.

    1984-01-01

    Apparatus for applying a vacuum to a nuclear fuel rod cladding tube's interior through its open end while girth welding an inserted end plug to its other end. An airtight housing has an orifice with a seal which can hermetically engage the tube's open end. A vacuum hose has one end connected to the housing and the other end connected to a vacuum pump. A mechanized device which moves the housing to engage or disengage its seal with the tube's open end includes at least one arm having one end attached to the housing and the other end pivotally attached to a movable table; an arm rotating device to coaxially align the housing's orifice with the welding-positioned tube; and a table moving device to engage the seal of the coaxially aligned orifice with the tube's open end. (author)

  18. Actual performance of mechanical ventilators in ICU: a multicentric quality control study

    Directory of Open Access Journals (Sweden)

    Govoni L

    2012-12-01

    Full Text Available Leonardo Govoni,1 Raffaele L Dellaca,1 Oscar Peñuelas,2,3 Giacomo Bellani,4,5 Antonio Artigas,3,6 Miquel Ferrer,3,7 Daniel Navajas,3,8,9 Antonio Pedotti,1 Ramon Farré3,81TBM-Lab, Dipartimento di Bioingegneria, Politecnico di Milano University, Milano, Italy; 2Hospital Universitario de Getafe – CIBERES, Madrid, Spain; 3CIBER de Enfermedades Respiratorias, Bunyola, Spain; 4Department of Experimental Medicine, University of Milan, Bicocca, Italy; 5Department of Perioperative Medicine and Intensive Care, San Gerardo Hospital, Monza (MI, Italy; 6Critical Care Center, Sabadell Hospital, Corporació Sanitaria Universitaria Parc Tauli, Universitat Autonoma de Barcelona, CIBERES, Spain; 7Department of Pneumology, Hospital Clinic, IDIBAPS, Barcelona, Spain; 8Unitat de Biofísica i Bioenginyeria, Facultat de Medicina, Universidad de Barcelona-IDIBAPS, Barcelona, Spain; 9Institut de Bioenginyeria de Catalunya, Barcelona, SpainAbstract: Even if the performance of a given ventilator has been evaluated in the laboratory under very well controlled conditions, inappropriate maintenance and lack of long-term stability and accuracy of the ventilator sensors may lead to ventilation errors in actual clinical practice. The aim of this study was to evaluate the actual performances of ventilators during clinical routines. A resistance (7.69 cmH2O/L/s – elastance (100 mL/cmH2O test lung equipped with pressure, flow, and oxygen concentration sensors was connected to the Y-piece of all the mechanical ventilators available for patients in four intensive care units (ICUs; n = 66. Ventilators were set to volume-controlled ventilation with tidal volume = 600 mL, respiratory rate = 20 breaths/minute, positive end-expiratory pressure (PEEP = 8 cmH2O, and oxygen fraction = 0.5. The signals from the sensors were recorded to compute the ventilation parameters. The average ± standard deviation and range (min–max of the ventilatory parameters were the following: inspired

  19. Lowering the YE+1 end-cap for CMS

    CERN Multimedia

    Maximilien Brice

    2007-01-01

    On 9 January 2007, the massive YE+1 end-cap was lowered into the CMS cavern. This is a very precise process as the crane must lower the end-cap through minimal clearance without tilt or sway. Once in the cavern, the end-cap is then positioned over the end of the barrel to detect particles produced in collisions that travel close to the axis of the beams.

  20. ATLAS end-caps 
on the move

    CERN Multimedia

    2007-01-01

    Two delicate and spectacular transport operations have been performed for ATLAS in recent weeks: the first end-cap tracker was installed in its final position, and one of the huge end-caps of the toroid magnet was moved to the top of the experiment’s shaft.

  1. Quantitative assessment of global and regional air trappings using non-rigid registration and regional specific volume change of inspiratory/expiratory CT scans: Studies on healthy volunteers and asthmatics

    International Nuclear Information System (INIS)

    Lee, Eun Sol; Seo, Joon Beom; Lee, Hyun Joo; Chae, Eun Jin; Lee, Sang Min; Oh, Sang Young; Kim, Nam Kug

    2015-01-01

    The purpose of this study was to compare air trapping in healthy volunteers with asthmatics using pulmonary function test and quantitative data, such as specific volume change from paired inspiratory CT and registered expiratory CT. Sixteen healthy volunteers and 9 asthmatics underwent paired inspiratory/expiratory CT. DeltaSV, which represents the ratio of air fraction released after exhalation, was measured with paired inspiratory and anatomically registered expiratory CT scans. Air trapping indexes, DeltaSV0.4 and DeltaSV0.5, were defined as volume fraction of lung below 0.4 and 0.5 DeltaSV, respectively. To assess the gravity effect of air-trapping, DeltaSV values of anterior and posterior lung at three different levels were measured and DeltaSV ratio of anterior lung to posterior lung was calculated. Color-coded DeltaSV map of the whole lung was generated and visually assessed. Mean DeltaSV, DeltaSV0.4, and DeltaSV0.5 were compared between healthy volunteers and asthmatics. In asthmatics, correlation between air trapping indexes and clinical parameters were assessed. Mean DeltaSV, DeltaSV0.4, and DeltaSV0.5 in asthmatics were significantly higher than those in healthy volunteer group (all p < 0.05). DeltaSV values in posterior lung in asthmatics were significantly higher than those in healthy volunteer group (p = 0.049). In asthmatics, air trapping indexes, such as DeltaSV0.5 and DeltaSV0.4, showed negative strong correlation with FEF25-75, FEV1, and FEV1/FVC. DeltaSV map of asthmatics showed abnormal geographic pattern in 5 patients (55.6%) and disappearance of anterior-posterior gradient in 3 patients (33.3%). Quantitative assessment of DeltaSV (the ratio of air fraction released after exhalation) shows the difference in extent of air trapping between health volunteers and asthmatics.

  2. Quantitative assessment of global and regional air trappings using non-rigid registration and regional specific volume change of inspiratory/expiratory CT scans: Studies on healthy volunteers and asthmatics

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sol; Seo, Joon Beom; Lee, Hyun Joo; Chae, Eun Jin; Lee, Sang Min; Oh, Sang Young; Kim, Nam Kug [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    The purpose of this study was to compare air trapping in healthy volunteers with asthmatics using pulmonary function test and quantitative data, such as specific volume change from paired inspiratory CT and registered expiratory CT. Sixteen healthy volunteers and 9 asthmatics underwent paired inspiratory/expiratory CT. DeltaSV, which represents the ratio of air fraction released after exhalation, was measured with paired inspiratory and anatomically registered expiratory CT scans. Air trapping indexes, DeltaSV0.4 and DeltaSV0.5, were defined as volume fraction of lung below 0.4 and 0.5 DeltaSV, respectively. To assess the gravity effect of air-trapping, DeltaSV values of anterior and posterior lung at three different levels were measured and DeltaSV ratio of anterior lung to posterior lung was calculated. Color-coded DeltaSV map of the whole lung was generated and visually assessed. Mean DeltaSV, DeltaSV0.4, and DeltaSV0.5 were compared between healthy volunteers and asthmatics. In asthmatics, correlation between air trapping indexes and clinical parameters were assessed. Mean DeltaSV, DeltaSV0.4, and DeltaSV0.5 in asthmatics were significantly higher than those in healthy volunteer group (all p < 0.05). DeltaSV values in posterior lung in asthmatics were significantly higher than those in healthy volunteer group (p = 0.049). In asthmatics, air trapping indexes, such as DeltaSV0.5 and DeltaSV0.4, showed negative strong correlation with FEF25-75, FEV1, and FEV1/FVC. DeltaSV map of asthmatics showed abnormal geographic pattern in 5 patients (55.6%) and disappearance of anterior-posterior gradient in 3 patients (33.3%). Quantitative assessment of DeltaSV (the ratio of air fraction released after exhalation) shows the difference in extent of air trapping between health volunteers and asthmatics.

  3. Spanning k-ended trees of 3-regular connected graphs

    Directory of Open Access Journals (Sweden)

    Hamed Ghasemian Zoeram

    2017-10-01

    Full Text Available A vertex of degree one is called an end-vertex and the set of end-vertices of G is denoted by End(G. For a positive integer k, a tree T be called k-ended tree if $|End(T| \\leq k$. In this paper, we obtain sufficient conditions for spanning k-trees of 3-regular connected graphs. We give a construction sequence of graphs satisfying the condition. At the end, we present a conjecture about spanning k-ended trees of 3-regular connected graphs.

  4. Ventilatory responses to exercise training in obese adolescents.

    Science.gov (United States)

    Mendelson, Monique; Michallet, Anne-Sophie; Estève, François; Perrin, Claudine; Levy, Patrick; Wuyam, Bernard; Flore, Patrice

    2012-10-15

    The aim of this study was to examine ventilatory responses to training in obese adolescents. We assessed body composition, pulmonary function and ventilatory responses (among which expiratory flow limitation and operational lung volumes) during progressive cycling exercise in 16 obese adolescents (OB) before and after 12 weeks of exercise training and in 16 normal-weight volunteers. As expected, obese adolescents' resting expiratory reserve volume was lower and inversely correlated with thoraco-abdominal fat mass (r = -0.74, p<0.0001). OB presented lower end expiratory (EELV) and end inspiratory lung volumes (EILV) at rest and during submaximal exercise, and modest expiratory flow limitation. After training, OB increased maximal aerobic performance (+19%) and maximal inspiratory pressure (93.7±31.4 vs. 81.9±28.2 cm H2O, +14%) despite lack of decrease in trunk fat and body weight. Furthermore, EELV and EILV were greater during submaximal exercise (+11% and +9% in EELV and EILV, respectively), expiratory flow limitation delayed but was not accompanied by increased V(T). However, submaximal exertional symptoms (dyspnea and leg discomfort) were significantly decreased (-71.3% and -70.7%, respectively). Our results suggest that exercise training can improve pulmonary function at rest (static inspiratory muscle strength) and exercise (greater operating lung volumes and delayed expiratory flow limitation) but these modifications did not entirely account for improved dyspnea and exercise performance in obese adolescents. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Gadolinium prevents high airway pressure-induced permeability increases in isolated rat lungs.

    Science.gov (United States)

    Parker, J C; Ivey, C L; Tucker, J A

    1998-04-01

    To determine the initial signaling event in the vascular permeability increase after high airway pressure injury, we compared groups of lungs ventilated at different peak inflation pressures (PIPs) with (gadolinium group) and without (control group) infusion of 20 microM gadolinium chloride, an inhibitor of endothelial stretch-activated cation channels. Microvascular permeability was assessed by using the capillary filtration coefficient (Kfc), a measure of capillary hydraulic conductivity. Kfc was measured after ventilation for 30-min periods with 7, 20, and 30 cmH2O PIP with 3 cmH2O positive end-expiratory pressure and with 35 cmH2O PIP with 8 cmH2O positive end-expiratory pressure. In control lungs, Kfc increased significantly to 1.8 and 3.7 times baseline after 30 and 35 cmH2O PIP, respectively. In the gadolinium group, Kfc was unchanged from baseline (0.060 +/- 0.010 ml . min-1 . cmH2O-1 . 100 g-1) after any PIP ventilation period. Pulmonary vascular resistance increased significantly from baseline in both groups before the last Kfc measurement but was not different between groups. These results suggest that microvascular permeability is actively modulated by a cellular response to mechanical injury and that stretch-activated cation channels may initiate this response through increases in intracellular calcium concentration.

  6. Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

    Science.gov (United States)

    Oda, Shinya; Otaki, Kei; Yashima, Nozomi; Kurota, Misato; Matsushita, Sachiko; Kumasaka, Airi; Kurihara, Hutaba; Kawamae, Kaneyuki

    2016-08-01

    Noninvasive positive pressure ventilation (NPPV) using a helmet is expected to cause inspiratory trigger delay due to the large collapsible and compliant chamber. We compared the work of breathing (WOB) of NPPV using a helmet or a full face-mask with that of invasive ventilation by tracheal intubation. We used a lung model capable of simulating spontaneous breathing (LUNGOO; Air Water Inc., Japan). LUNGOO was set at compliance (C) = 50 mL/cmH2O and resistance (R) = 5 cmH2O/L/s for normal lung simulation, C = 20 mL/cmH2O and R = 5 cmH2O/L/s for restrictive lung, and C = 50 mL/cmH2O and R = 20 cmH2O/L/s for obstructive lung. Muscle pressure was fixed at 25 cmH2O and respiratory rate at 20 bpm. Pressure support ventilation and continuous positive airway pressure were performed with each interface placed on a dummy head made of reinforced plastic that was connected to LUNGOO. We tested the inspiratory WOB difference between the interfaces with various combinations of ventilator settings (positive end-expiratory pressure 5 cmH2O; pressure support 0, 5, and 10 cmH2O). In the normal lung and restrictive lung models, WOB decreased more with the face-mask than the helmet, especially when accompanied by the level of pressure support. In the obstructive lung model, WOB with the helmet decreased compared with the other two interfaces. In the mixed lung model, there were no significant differences in WOB between the three interfaces. NPPV using a helmet is more effective than the other interfaces for WOB in obstructive lung disease.

  7. The antigravity suit in neurosurgery. Cardiovascular responses in seated neurosurgical patients.

    Science.gov (United States)

    Brodrick, P M; Ingram, G S

    1988-09-01

    The haemodynamic responses associated with inflation of the antigravity suit (G suit, aviation type) to 8.0 kPa were studied in a series of 40 patients who underwent neurosurgical operations in the sitting position. The study showed statistically significant increases in systolic arterial pressure (p less than 0.005) and mean central venous pressure (p less than 0.001) with inflation of the suit. The systolic arterial and mean central venous pressures remained significantly elevated immediately before deflation of the suit at the end of the operation (p less than 0.001 and p less than 0.005 respectively). The addition of 0.8-1.0 kPa positive end expiratory pressure during suit inflation was also investigated. A further increase in central venous pressure occurred but this did not achieve statistical significance.

  8. Evaluation of COPD Longitudinally to Identify Predictive Surrogate End-points (ECLIPSE)

    DEFF Research Database (Denmark)

    Vestbo, J; Anderson, W; Coxson, H O

    2008-01-01

    Chronic obstructive pulmonary disease (COPD) is a heterogeneous disease and not well understood. The forced expiratory volume in one second is used for the diagnosis and staging of COPD, but there is wide acceptance that it is a crude measure and insensitive to change over shorter periods of time...

  9. High-Frequency Percussive Ventilation and Low Tidal Volume Ventilation in Burns: A Randomized Controlled Trial

    Science.gov (United States)

    2010-01-01

    incidence of ventilator-associated pneumonia ( VAP ) in patients with inha- lation injury when supported with HFPV compared with conventional modes of...mean ratio of PaO2 to FIO2 was 58 6 with a mean positive end- expiratory pressure of 22 2 cm H2O before rescue. Two of these patients were...a sample size of 110 patients in each arm would have been required to detect a difference in VAP with 80% power. A multicentered study would be

  10. Effects of Hemibridge with Ball and Balloon Exercise on Forced Expiratory Volume and Pain in Patients with Chronic Low Back Pain: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Jorida Fernandes

    2017-08-01

    Full Text Available Background and objectives: Suboptimal breathing patterns and impairments of posture and trunk stability are often associated with musculoskeletal complaints such as low back pain. Respiration is also affected by poor neuromuscular control of core muscles. Immediate effects of hemibridge with ball and balloon exercise has been studied on chronic pain in athlete population. Objective: To evaluate the effects of hemibridge with ball and balloon exercise on pain, forced expiratory volume and functional abilities in patients with chronic low back pain using Visual Analogue Scale (VAS, Forced Expiratory Volume (FEV and Modified Oswestry Disability Questionnaire (MODQ. Methods: The present experimental study was conducted among 30 participants between the age of 21 to 55 years with chronic non-specific LBP. The participants were given a hemibridge with ball and balloon exercise. Pre-interventional and 3rd day Post-interventional outcome measurements were taken using VAS, FEV1 and FEV6 and MODQ. Results: The difference between pre-and post of VAS was statistically highly significant (p=0.0001. The p value of FEV6 and MODQ by paired t test was statistically significant with p value of 0.02 and 0.0007 respectively. Conclusion: The study concludes that there is an immediate effect of hemibridge with ball and balloon exercise on pain, FEV6 and functional ability in patients with chronic LBP.

  11. Apparatus for assembling and welding end plugs to nuclear fuel cladding tubes and inspecting the end plug welds on an automated basis

    International Nuclear Information System (INIS)

    Schoenig, F.C. Jr.; Walker, E.S.; Cueman, M.K.; Haughton, R.A.; Zuloaga, J.A. Jr.

    1989-01-01

    This patent describes an automated apparatus for welding a separate end plug to one open end of each of a succession of nuclear fuel cladding tubes and for inspecting each end plug weld. The apparatus comprising, in combination: a welding station; a cooldown station for cooling each end plug weld in an inert gas atmosphere; a serial number reader station for reading a serial number on each end plug; a first weld inspection station; a second weld inspection station for generating second weld inspection data; a computer system linked with the serial number reader and the first and second weld inspection stations; an input queue for holding a plurality of tubes; a tube transporter for periodically picking individual tubes from the input queque and conveying the tubes in a direction transverse to their tube axis in indexing steps to index positions respectively axially aligned with the welding, serial number reader, and first and second weld inspection stations; and a sorter positioned at an output end of the tube transporter

  12. Respiratory mechanics by least squares fitting in mechanically ventilated patients: application on flow-limited COPD patients.

    Science.gov (United States)

    Volta, Carlo A; Marangoni, Elisabetta; Alvisi, Valentina; Capuzzo, Maurizia; Ragazzi, Riccardo; Pavanelli, Lina; Alvisi, Raffaele

    2002-01-01

    Although computerized methods of analyzing respiratory system mechanics such as the least squares fitting method have been used in various patient populations, no conclusive data are available in patients with chronic obstructive pulmonary disease (COPD), probably because they may develop expiratory flow limitation (EFL). This suggests that respiratory mechanics be determined only during inspiration. Eight-bed multidisciplinary ICU of a teaching hospital. Eight non-flow-limited postvascular surgery patients and eight flow-limited COPD patients. Patients were sedated, paralyzed for diagnostic purposes, and ventilated in volume control ventilation with constant inspiratory flow rate. Data on resistance, compliance, and dynamic intrinsic positive end-expiratory pressure (PEEPi,dyn) obtained by applying the least squares fitting method during inspiration, expiration, and the overall breathing cycle were compared with those obtained by the traditional method (constant flow, end-inspiratory occlusion method). Our results indicate that (a) the presence of EFL markedly decreases the precision of resistance and compliance values measured by the LSF method, (b) the determination of respiratory variables during inspiration allows the calculation of respiratory mechanics in flow limited COPD patients, and (c) the LSF method is able to detect the presence of PEEPi,dyn if only inspiratory data are used.

  13. Review: Open-ended objects: A tool for brainstorming

    NARCIS (Netherlands)

    van den Broek, Egon

    2010-01-01

    Cruz and Gaudron sketch the concept of open-ended objects that are positioned as facilitating brainstorming workshops for human-computer interaction (HCI) purposes. Open-ended objects are characterized by four features: those that provide a preliminary experience, a tangible representation of a

  14. Lung volume and expiratory flow rates from pre- to post-puberty.

    Science.gov (United States)

    Smith, Joshua R; Emerson, Sam R; Kurti, Stephanie P; Gandhi, Kirti; Harms, Craig A

    2015-08-01

    The purpose was to determine if the airways and lungs grow disproportionately from pre- to post-puberty in boys and girls. We hypothesized that the airways grow at a slower rate than lung volume (i.e. dysanapsis growth) during puberty and boys would exhibit more dysanaptic growth compared to girls. Twenty-one pre-pubescent children [11 boys (pre 10.1 ± 0.5 years, post 15.3 ± 0.5 years); 10 girls (pre 9.4 ± 1.0 years, post 14.1 ± 1.0 years)] performed pulmonary function tests (PFTs) ~5 years ago from an original cohort of 40 children. These 21 children performed PFTs, which included forced vital capacity (FVC) and forced expiratory flow at 50 % FVC (FEF50). Static pressure at 50 % of FVC [Pst(L)50 %] was estimated based on age. Dysanapsis ratio (DR) was calculated [FEF50 × FVC(-1) × Pst(L) 50 % (-1) ]. Maturation status was determined via Tanner stages. Stage of maturation was not different (p > 0.05) between boys and girls (4.2 ± 0.6 stage vs. 3.7 ± 0.7 stage, respectively). FVC and FEF50 increased (p 0.05) from pre- to post-puberty. FEF50 and FVC significantly increased and DR decreased (p puberty for both sexes. Post-puberty, boys had a significantly larger FVC, but FEF50, DR, and FEF50/FVC were not different (p > 0.05) compared to girls. These data suggest that dysanaptic growth occurs during puberty and that it is not different between boys and girls.

  15. Apparatus for inspecting the quality of nuclear fuel rod ends

    International Nuclear Information System (INIS)

    Brashier, R.W.; Pfau, E.D.

    1990-01-01

    This patent describes an apparatus for inspecting the quality of both ends of nuclear fuel rods. It comprises: a housing including a pair of longitudinally separated slots for receiving X-ray downwardly therethrough from an external source and so as to define first and second longitudinally spaced apart operating positions, means for serially guiding nuclear fuel rods longitudinally through the housing and to a first rod position wherein the forward ends of the rods are aligned below the first operating position and to a second rod position wherein the rear ends of the rods are aligned below the second operating position, belt conveyor assembly means for serially advancing X-ray film cartridges longitudinally through the housing and below the rods, and so that each cartridge may be selectively aligned below the first and second operating positions; and table means supported by the conveyor frame for selectively lifting the film cartridges supported by the belts and so that the conveyor belts may be advanced while the film cartridges are held stationary

  16. Can Preoperative Peak Expiratory Flow Predict Postoperative Pulmonary Complications in Lung Cancer Patients Undergoing Lobectomy?

    Directory of Open Access Journals (Sweden)

    Kun ZHOU

    2017-09-01

    Full Text Available Background and objective Postoperative pulmonary complications (PPCs, especially postoperative pneumonia (POP, directly affect the rapid recovery of lung cancer patients after surgery. Peak expiratory flow (PEF can reflect airway patency and cough efficiency. Moreover, cough impairment may lead to accumulation of pulmonary secretions which can increase the risk of PPCs. The aim of this study is to investigate the effect of preoperative PEF on PPCs in patients with lung cancer. Methods Retrospective research was conducted on 433 lung cancer patients who underwent lobectomy at the West China Hospital of Sichuan University from January 2014 to December 2015. The associations between preoperative PEF and PPCs were analyzed based on patients’ basic characteristics and clinical data in hospital. Results Preoperative PEF value in PPCs group (280.93±88.99 L/min was significantly lower than that in non-PPCs group (358.38±93.69 L/min (P320 L/min group (9.4%(P<0.001. Conclusion Preoperative PEF and PPCs are correlated, and PEF may be used as a predictor of PPCs.

  17. Prediction of post-operative pulmonary function after lobectomy for primary lung cancer: A comparison among counting method, effective lobar volume, and lobar collapsibility using inspiratory/expiratory CT

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, Hidetake, E-mail: h-yabu@med.kyushu-u.ac.jp [Department of Health Sciences, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Kawanami, Satoshi, E-mail: kawanami_01@mac.com [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Kamitani, Takeshi, E-mail: kamitani@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Yonezawa, Masato, E-mail: ymasato@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Yamasaki, Yuzo, E-mail: yyama@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Yamanouchi, Torahiko, E-mail: tora0228jp@yahoo.co.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Nagao, Michinobu, E-mail: minagao@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Okamoto, Tatsuro, E-mail: tatsuro@surg2.med.kyushu-u.ac.jp [Department of Surgery and Science, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan); Honda, Hiroshi, E-mail: honda@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Kyushu University Graduate School of Medical Sciences, Fukuoka (Japan)

    2016-11-15

    Highlights: • ΔFEV{sub 1.0} and ppoΔFEV{sub 1.0} using lobar collapsibility were strongly correlated. • ΔVC and ppoΔVC using effective lobar volume were strongly correlated. • Counting method was inferior to lobar collapsibility for prediction of ppoFEV{sub 1.0}. • Inspiratory/expiratory CT is useful to predict post-operative pulmonary function. - Abstract: Purpose: To compare the predictabilities of postoperative pulmonary function after lobectomy for primary lung cancer among counting method, effective lobar volume, and lobar collapsibility. Methods: Forty-nine patients who underwent lobectomy for primary lung cancer were enrolled. All patients underwent inspiratory/expiratory CT and pulmonary function tests 2 weeks before surgery and postoperative pulmonary function tests 6–7 months after surgery. Pulmonary function losses (ΔFEV{sub 1.0} and ΔVC) were calculated from the pulmonary function tests. Predictive postoperative pulmonary function losses (ppoΔFEV{sub 1.0} and ppoΔVC) were calculated using counting method, effective volume, and lobar collapsibility. Correlations and agreements between ΔFEV{sub 1.0} and ppoFEV{sub 1.0} and those between ΔVC and ppoΔVC were tested among three methods using Spearman’s correlation coefficient and Bland-Altman plots. Results: ΔFEV{sub 1.0} and ppoΔFEV{sub 1.0insp-exp} were strongly correlated (r = 0.72), whereas ΔFEV{sub 1.0} and ppoΔFEV{sub 1.0count} and ΔFEV{sub 1.0} and Pred. ΔFEV{sub 1.0eff.vol.} were moderately correlated (r = 0.50, 0.56). ΔVC and ppoΔVC{sub eff.vol.} (r = 0.71) were strongly correlated, whereas ΔVC and ppoΔVC{sub count}, and ΔVC and ppoΔVC {sub insp-exp} were moderately correlated (r = 0.55, 0.42). Conclusions: Volumetry from inspiratory/expiratory CT data could be useful to predict postoperative pulmonary function after lobectomy for primary lung cancer.

  18. Reversible end-to-end assembly of gold nanorods using a disulfide-modified polypeptide

    International Nuclear Information System (INIS)

    Walker, David A; Gupta, Vinay K

    2008-01-01

    Directing the self-assembly of colloidal particles into nanostructures is of great interest in nanotechnology. Here, reversible end-to-end assembly of gold nanorods (GNR) is induced by pH-dependent changes in the secondary conformation of a disulfide-modified poly(L-glutamic acid) (SSPLGA). The disulfide anchoring group drives chemisorption of the polyacid onto the end of the gold nanorods in an ethanolic solution. A layer of poly(vinyl pyrrolidone) is adsorbed on the positively charged, surfactant-stabilized GNR to screen the surfactant bilayer charge and provide stability for dispersion of the GNR in ethanol. For comparison, irreversible end-to-end assembly using a bidentate ligand, namely 1,6-hexanedithiol, is also performed. Characterization of the modified GNR and its end-to-end linking behavior using SSPLGA and hexanedithiol is performed using dynamic light scattering (DLS), UV-vis absorption spectroscopy and transmission electron microscopy (TEM). Experimental results show that, in a colloidal solution of GNR-SSPLGA at a pH∼3.5, where the PLGA is in an α-helical conformation, the modified GNR self-assemble into one-dimensional nanostructures. The linking behavior can be reversed by increasing the pH (>8.5) to drive the conformation of the polypeptide to a random coil and this reversal with pH occurs rapidly within minutes. Cycling the pH multiple times between low and high pH values can be used to drive the formation of the nanostructures of the GNR and disperse them in solution.

  19. Influence of heart rhythm, breathing and arm position during computed tomography scanning on the registration accuracy of electro anatomical map (EAM) images, left atrium three-dimensional computed tomography angiography images, and fluoroscopy time during ablation to treat atrial fibrillation

    International Nuclear Information System (INIS)

    Chono, Taiki; Shimoshige, Shinya; Yoshikawa, Kenta; Mizonobe, Kazuhusa; Ogura, Keishi

    2013-01-01

    In CARTOMERGE for treatment of atrial fibrillation (AF) by ablation, by integrating electro anatomical map (EAM) and left atrium three-dimensional computed tomography angiography (3D-CTA) images, identification of the ablation points is simplified and the procedure can be made carried out more rapidly. However, the influence that heart rhythm, breathing and arm position during CT scanning have on registration accuracy and fluoroscopy time is not clear. To clarify the influence on registration accuracy and fluoroscopy time of heart rhythm, breathing and arm position during CT scanning. The patients were CT-scanned during both sinus rhythm (SR) and AF in each study subject. We evaluated the registration accuracy of images reconstructed between the cardiac cycle and assessed the registration accuracy and fluoroscopy time of images obtained during inspiratory breath-hold, expiratory breath-hold and up and down position of the arm. Although the registration accuracy of the EAM image and left atrium 3D-CTA image showed a significant difference during SR, no significant difference was seen during AF. Expiratory breath-hold and down position of the arm resulted in the highest registration accuracy and the shortest fluoroscopy time. However, arm position had no significant effect on registration accuracy. Heart rhythm and breathing during CT scanning have a significant effect on the registration accuracy of EAM images, left atrium 3D-CTA images, and fluoroscopy time. (author)

  20. Predictors of advanced chronic kidney disease and end-stage renal disease in HIV-positive persons

    DEFF Research Database (Denmark)

    Nielsen, Lene Ryom; Mocroft, Amanda; Kirk, Ole

    2014-01-01

    Whilst several antiretroviral drugs have been associated with moderate chronic kidney disease (CKD), their contribution to advanced CKD and end-stage renal disease (ESRD) remain unknown.......Whilst several antiretroviral drugs have been associated with moderate chronic kidney disease (CKD), their contribution to advanced CKD and end-stage renal disease (ESRD) remain unknown....

  1. [Application of injection test in confirming the ideal position of esophageal balloon catheter].

    Science.gov (United States)

    Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin

    2017-09-01

    To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0

  2. Evaluation of changes in central airway dimensions, lung area and mean lung density at paired inspiratory/expiratory high-resolution computed tomography

    International Nuclear Information System (INIS)

    Ederle, J.R.; Heussel, C.P.; Hast, J.; Ley, S.; Thelen, M.; Kauczor, H.U.; Fischer, B.; Beek, E.J.R. van

    2003-01-01

    The aim of this study was to improve the understanding of interdependencies of dynamic changes in central airway dimensions, lung area and lung density on HRCT. The HRCT scans of 156 patients obtained at full inspiratory and expiratory position were evaluated retrospectively. Patients were divided into four groups according to lung function tests: normal subjects (n=47); obstructive (n=74); restrictive (n=19); or mixed ventilatory impairment (n=16). Mean lung density (MLD) was correlated with cross-sectional area of the lung (CSA L ), cross-sectional area of the trachea (CSA T ) and diameter of main-stem bronchi (D B ). The CSA L was correlated with CSA T and D B . MLD correlated with CSA L in normal subjects (r=-0.66, p T in the control group (r=-0.50, p B was found (r=-0.52, p L and CSA T correlated in the control group (r=0.67, p L and D B correlated in the control group (r=0.42, p<0.0001) and in patients with obstructive lung disease (r=0.24, p<0.05). Correlations for patients with restrictive and mixed lung disease were constantly lower. Dependencies between central and peripheral airway dimensions and lung parenchyma are demonstrated by HRCT. Best correlations are observed in normal subjects and patients with obstructive lung disease. Based on these findings we postulate that the dependencies are the result of air-flow and pressure patterns. (orig.)

  3. Open lung approach versus standard protective strategies: Effects on driving pressure and ventilatory efficiency during anesthesia - A pilot, randomized controlled trial.

    Science.gov (United States)

    Ferrando, Carlos; Suarez-Sipmann, Fernando; Tusman, Gerardo; León, Irene; Romero, Esther; Gracia, Estefania; Mugarra, Ana; Arocas, Blanca; Pozo, Natividad; Soro, Marina; Belda, Francisco J

    2017-01-01

    Low tidal volume (VT) during anesthesia minimizes lung injury but may be associated to a decrease in functional lung volume impairing lung mechanics and efficiency. Lung recruitment (RM) can restore lung volume but this may critically depend on the post-RM selected PEEP. This study was a randomized, two parallel arm, open study whose primary outcome was to compare the effects on driving pressure of adding a RM to low-VT ventilation, with or without an individualized post-RM PEEP in patients without known previous lung disease during anesthesia. Consecutive patients scheduled for major abdominal surgery were submitted to low-VT ventilation (6 ml·kg-1) and standard PEEP of 5 cmH2O (pre-RM, n = 36). After 30 min estabilization all patients received a RM and were randomly allocated to either continue with the same PEEP (RM-5 group, n = 18) or to an individualized open-lung PEEP (OL-PEEP) (Open Lung Approach, OLA group, n = 18) defined as the level resulting in maximal Cdyn during a decremental PEEP trial. We compared the effects on driving pressure and lung efficiency measured by volumetric capnography. OL-PEEP was found at 8±2 cmH2O. 36 patients were included in the final analysis. When compared with pre-RM, OLA resulted in a 22% increase in compliance and a 28% decrease in driving pressure when compared to pre-RM. These parameters did not improve in the RM-5. The trend of the DP was significantly different between the OLA and RM-5 groups (p = 0.002). VDalv/VTalv was significantly lower in the OLA group after the RM (p = 0.035). Lung recruitment applied during low-VT ventilation improves driving pressure and lung efficiency only when applied as an open-lung strategy with an individualized PEEP in patients without lung diseases undergoing major abdominal surgery. ClinicalTrials.gov NCT02798133.

  4. Open lung approach versus standard protective strategies: Effects on driving pressure and ventilatory efficiency during anesthesia - A pilot, randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Carlos Ferrando

    Full Text Available Low tidal volume (VT during anesthesia minimizes lung injury but may be associated to a decrease in functional lung volume impairing lung mechanics and efficiency. Lung recruitment (RM can restore lung volume but this may critically depend on the post-RM selected PEEP. This study was a randomized, two parallel arm, open study whose primary outcome was to compare the effects on driving pressure of adding a RM to low-VT ventilation, with or without an individualized post-RM PEEP in patients without known previous lung disease during anesthesia.Consecutive patients scheduled for major abdominal surgery were submitted to low-VT ventilation (6 ml·kg-1 and standard PEEP of 5 cmH2O (pre-RM, n = 36. After 30 min estabilization all patients received a RM and were randomly allocated to either continue with the same PEEP (RM-5 group, n = 18 or to an individualized open-lung PEEP (OL-PEEP (Open Lung Approach, OLA group, n = 18 defined as the level resulting in maximal Cdyn during a decremental PEEP trial. We compared the effects on driving pressure and lung efficiency measured by volumetric capnography.OL-PEEP was found at 8±2 cmH2O. 36 patients were included in the final analysis. When compared with pre-RM, OLA resulted in a 22% increase in compliance and a 28% decrease in driving pressure when compared to pre-RM. These parameters did not improve in the RM-5. The trend of the DP was significantly different between the OLA and RM-5 groups (p = 0.002. VDalv/VTalv was significantly lower in the OLA group after the RM (p = 0.035.Lung recruitment applied during low-VT ventilation improves driving pressure and lung efficiency only when applied as an open-lung strategy with an individualized PEEP in patients without lung diseases undergoing major abdominal surgery.ClinicalTrials.gov NCT02798133.

  5. Position indication apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Masuda, T

    1964-02-24

    A plurality of magnetically operated switches are spaced equally in the hollow tube of a control rod actuating mechanism. One side of each switch is connected, via a low resistance, to a corresponding tap of a low resistance voltage divider network consisting of an equivalent number of low resistance sections with the opposite side of each switch connected to a common conducting wire A. To both ends of the voltage dividing network are connected, respectively, conducting wires B and C. Wires A, B, and C are further coupled to a fuel rod position indicator comprising a voltmeter and power source external to the control rod actuating member. The control rod actuating member is adapted to slide in the hollow tube so that switches passing a position facing a magnet secured to the lower end of the actuating member are rendered closed. Hence, the position of the control rod may be read by reading the voltage off the meter.

  6. First characterization of the expiratory flow increase technique: method development and results analysis

    International Nuclear Information System (INIS)

    Maréchal, L; Barthod, C; Jeulin, J C

    2009-01-01

    This study provides an important contribution to the definition of the expiratory flow increase technique (EFIT). So far, no measuring means were suited to assess the manual EFIT performed on infants. The proposed method aims at objectively defining the EFIT based on the quantification of pertinent cognitive parameters used by physiotherapists when practicing. We designed and realized customized instrumented gloves endowed with pressure and displacement sensors, and the associated electronics and software. This new system is specific to the manoeuvre, to the user and innocuous for the patient. Data were collected and analysed on infants with bronchiolitis managed by an expert physiotherapist. The analysis presented is realized on a group of seven subjects (mean age: 6.1 months, SD: 1.1; mean chest circumference: 44.8 cm, SD: 1.9). The results are consistent with the physiotherapist's tactility. In spite of inevitable variability due to measurements on infants, repeatable quantitative data could be reported regarding the manoeuvre characteristics: the magnitudes of displacements do not exceed 10 mm on both hands; the movement of the thoracic hand is more vertical than the movement of the abdominal hand; the maximum applied pressure with the thoracic hand is about twice higher than with the abdominal hand; the thrust of the manual compression lasts (590 ± 62) ms. Inter-operators measurements are in progress in order to generalize these results

  7. The effects of smokeless cookstoves on peak expiratory flow rates in rural Honduras.

    Science.gov (United States)

    Rennert, W P; Porras Blanco, R M; Muniz, G B

    2015-09-01

    The use of biomass fuel for cooking in traditional cookstove designs negatively affects respiratory health of communities in developing countries. Indoor pollution affects particularly women and children, who are participating in food preparation. The effects of smokeless cookstove designs on indoor pollution are well documented, but few studies exist to assess the effects of improved stove designs on the respiratory health of community members. This study uses peak expiratory flow rate (PEFR) measurements in a before-and-after format to assess respiratory function of inhabitants of all 30 houses of Buenas Noches in central Honduras. PEFRs are measured before and 6 months after the installation of Justa stoves in people's homes. Health behaviors, respiratory symptoms and fire wood use are evaluated in a door-to-door survey format. A total of 137 eligible women and children between 6 and 14 years participated in the study. PEFR improved by 9.9-18.5% (P < 0.001) depending on the participants' exposure to indoor pollution. Health complaints like cough and behaviors like clinic visits did not change with the introduction of smokeless cookstove technology. Smokeless stoves improve respiratory health in an environment of high levels of indoor pollution. © The Author 2014. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Impressions That Last: Particularly Negative and Positive Experiences Reported by Parents Five Years after the End of a Child's Successful Cancer Treatment or Death.

    Directory of Open Access Journals (Sweden)

    Lisa Ljungman

    Full Text Available To describe the experience of parenting a child diagnosed with cancer by examining particularly negative and positive experiences reported by parents of childhood cancer survivors and parents of children lost to cancer.168 parents (88 mothers, 80 fathers participated. Data were collected five years after the end of successful treatment or the child's death. The parents' experiences were identified by open-ended semi-structured questions about particularly negative and positive experiences of the child's cancer. An inductive approach was used in which the manifest verbal content of the answers was analysed using content analysis.The analysis revealed eight categories of negative experience (child late effects; distressing events; healthcare; impaired relationships; long-term psychological consequences; own reactions; surrounding institutions; the fact that the child got cancer and seven categories of positive experience (healthcare; improved relationships; long-term consequences for the child; personal development; support systems; treatment outcome; unexpected joy. The categories were related to past events or to the present situation. The findings indicate variations in experiences between parents of survivors and bereaved parents, and between fathers and mothers, as some experiences were only reported by parents of survivors and some experiences were only reported by mothers.The results highlight the importance of past and present events to parents, and accordingly the long-lasting impact of paediatric cancer on parents. The results also point to the wide range of negative as well as positive experiences involved in parenting a child diagnosed with cancer, and provide a comprehensive understanding of the overall experience for parents of children with cancer. Specifically, the findings give guidance to healthcare providers by illustrating the need to provide healthcare personnel with continuous training in communication skills, offering

  9. Síndrome do desconforto respiratório agudo pulmonar e extrapulmonar: existem diferenças? Pulmonary and extrapulmonary acute respiratory distress syndrome: are they different?

    Directory of Open Access Journals (Sweden)

    Cristiane S. N. Baez Garcia

    2008-06-01

    between pulmonary and extrapulmonary ARDS, and discusses the interactions between morpho-functional aspects and response to differents therapies, both in experimental and clinical studies. CONTENTS: This systematic review included clinical and experimental ARDS studies found in MedLine and SciElo databases in the last 20 years. Many researchers acknowledge that experimental pulmonary and extrapulmonary ARDS are not identical with regard to morpho-functional aspects, the response to positive end-expiratory pressure (PEEP, recruitment manoeuvre, prone position and other adjunctive therapies. However, contradictory results have been reported in different clinical studies, which could be attributed to the difficulty of classifying ARDS in one or the other category, and to the assurance regarding the onset, phase and severity of ARDS in all patients. CONCLUSIONS: Heterogeneous ARDS patients are still considered as belonging to one syndrome, and are therefore treated in a similar manner. Thus, it is important to understand the pathophysiology of pulmonary and extrapulmonary ARDS in an attempt to better treat these patients.

  10. Fluorescent optical position sensor

    Science.gov (United States)

    Weiss, Jonathan D.

    2005-11-15

    A fluorescent optical position sensor and method of operation. A small excitation source side-pumps a localized region of fluorescence at an unknown position along a fluorescent waveguide. As the fluorescent light travels down the waveguide, the intensity of fluorescent light decreases due to absorption. By measuring with one (or two) photodetectors the attenuated intensity of fluorescent light emitted from one (or both) ends of the waveguide, the position of the excitation source relative to the waveguide can be determined by comparing the measured light intensity to a calibrated response curve or mathematical model. Alternatively, excitation light can be pumped into an end of the waveguide, which generates an exponentially-decaying continuous source of fluorescent light along the length of the waveguide. The position of a photodetector oriented to view the side of the waveguide can be uniquely determined by measuring the intensity of the fluorescent light emitted radially at that location.

  11. An asthma patient with steroid-resistant decrease in peak expiratory flow after the Great East Japan earthquake showing spontaneous recovery after 1 month.

    Science.gov (United States)

    Yanagimoto, Shintaro; Haida, Michiko; Suko, Matsunobu

    2012-01-01

    People living in Japan were affected in various ways after the Great East Japan earthquake of March 11, 2011. A 52-year-old female asthma patient not directly affected by the disaster experienced a decrease in peak expiratory flow (PEF) immediately after the earthquake. Despite increasing the inhaled and oral corticosteroid doses, her PEF did not recover. One month later, her PEF level abruptly returned to normal with minimal medications, which were previously ineffective, and the asthma-related symptoms vanished. The stabilization of her state of mind and actual social state seemed to be a part of the reason for the patient's recovery.

  12. Kinetics of end-to-end collision in short single-stranded nucleic acids.

    Science.gov (United States)

    Wang, Xiaojuan; Nau, Werner M

    2004-01-28

    A novel fluorescence-based method, which entails contact quenching of the long-lived fluorescent state of 2,3-diazabicyclo[2.2.2]-oct-2-ene (DBO), was employed to measure the kinetics of end-to-end collision in short single-stranded oligodeoxyribonucleotides of the type 5'-DBO-(X)n-dG with X = dA, dC, dT, or dU and n = 2 or 4. The fluorophore was covalently attached to the 5' end and dG was introduced as an efficient intrinsic quencher at the 3' terminus. The end-to-end collision rates, which can be directly related to the efficiency of intramolecular fluorescence quenching, ranged from 0.1 to 9.0 x 10(6) s(-1). They were strongly dependent on the strand length, the base sequence, as well as the temperature. Oligonucleotides containing dA in the backbone displayed much slower collision rates and significantly higher positive activation energies than strands composed of pyrimidine bases, suggesting a higher intrinsic rigidity of oligoadenylate. Comparison of the measured collision rates in short single-stranded oligodeoxyribonucleotides with the previously reported kinetics of hairpin formation indicates that the intramolecular collision is significantly faster than the nucleation step of hairpin closing. This is consistent with the configurational diffusion model suggested by Ansari et al. (Ansari, A.; Kuznetsov, S. V.; Shen, Y. Proc.Natl. Acad. Sci. USA 2001, 98, 7771-7776), in which the formation of misfolded loops is thought to slow hairpin formation.

  13. Physiologic effects of alveolar recruitment and inspiratory pauses during moderately-high-frequency ventilation delivered by a conventional ventilator in a severe lung injury model.

    Directory of Open Access Journals (Sweden)

    Ricardo Luiz Cordioli

    Full Text Available To investigate whether performing alveolar recruitment or adding inspiratory pauses could promote physiologic benefits (VT during moderately-high-frequency positive pressure ventilation (MHFPPV delivered by a conventional ventilator in a porcine model of severe acute respiratory distress syndrome (ARDS.Prospective experimental laboratory study with eight pigs. Induction of acute lung injury with sequential pulmonary lavages and injurious ventilation was initially performed. Then, animals were ventilated on a conventional mechanical ventilator with a respiratory rate (RR = 60 breaths/minute and PEEP titrated according to ARDS Network table. The first two steps consisted of a randomized order of inspiratory pauses of 10 and 30% of inspiratory time. In final step, we removed the inspiratory pause and titrated PEEP, after lung recruitment, with the aid of electrical impedance tomography. At each step, PaCO2 was allowed to stabilize between 57-63 mmHg for 30 minutes.The step with RR of 60 after lung recruitment had the highest PEEP when compared with all other steps (17 [16,19] vs 14 [10, 17]cmH2O, but had lower driving pressures (13 [13,11] vs 16 [14, 17]cmH2O, higher P/F ratios (212 [191,243] vs 141 [105, 184] mmHg, lower shunt (23 [20, 23] vs 32 [27, 49]%, lower dead space ventilation (10 [0, 15] vs 30 [20, 37]%, and a more homogeneous alveolar ventilation distribution. There were no detrimental effects in terms of lung mechanics, hemodynamics, or gas exchange. Neither the addition of inspiratory pauses or the alveolar recruitment maneuver followed by decremental PEEP titration resulted in further reductions in VT.During MHFPPV set with RR of 60 bpm delivered by a conventional ventilator in severe ARDS swine model, neither the inspiratory pauses or PEEP titration after recruitment maneuver allowed reduction of VT significantly, however the last strategy decreased driving pressures and improved both shunt and dead space.

  14. Does Regional Lung Strain Correlate With Regional Inflammation in Acute Respiratory Distress Syndrome During Nonprotective Ventilation? An Experimental Porcine Study.

    Science.gov (United States)

    Retamal, Jaime; Hurtado, Daniel; Villarroel, Nicolás; Bruhn, Alejandro; Bugedo, Guillermo; Amato, Marcelo Britto Passos; Costa, Eduardo Leite Vieira; Hedenstierna, Göran; Larsson, Anders; Borges, João Batista

    2018-06-01

    It is known that ventilator-induced lung injury causes increased pulmonary inflammation. It has been suggested that one of the underlying mechanisms may be strain. The aim of this study was to investigate whether lung regional strain correlates with regional inflammation in a porcine model of acute respiratory distress syndrome. Retrospective analysis of CT images and positron emission tomography images using [F]fluoro-2-deoxy-D-glucose. University animal research laboratory. Seven piglets subjected to experimental acute respiratory distress syndrome and five ventilated controls. Acute respiratory distress syndrome was induced by repeated lung lavages, followed by 210 minutes of injurious mechanical ventilation using low positive end-expiratory pressures (mean, 4 cm H2O) and high inspiratory pressures (mean plateau pressure, 45 cm H2O). All animals were subsequently studied with CT scans acquired at end-expiration and end-inspiration, to obtain maps of volumetric strain (inspiratory volume - expiratory volume)/expiratory volume, and dynamic positron emission tomography imaging. Strain maps and positron emission tomography images were divided into 10 isogravitational horizontal regions-of-interest, from which spatial correlation was calculated for each animal. The acute respiratory distress syndrome model resulted in a decrease in respiratory system compliance (20.3 ± 3.4 to 14.0 ± 4.9 mL/cm H2O; p < 0.05) and oxygenation (PaO2/FIO2, 489 ± 80 to 92 ± 59; p < 0.05), whereas the control animals did not exhibit changes. In the acute respiratory distress syndrome group, strain maps showed a heterogeneous distribution with a greater concentration in the intermediate gravitational regions, which was similar to the distribution of [F]fluoro-2-deoxy-D-glucose uptake observed in the positron emission tomography images, resulting in a positive spatial correlation between both variables (median R = 0.71 [0.02-0.84]; p < 0.05 in five of seven animals

  15. Time-Resolved Quantitative Analysis of the Diaphragms During Tidal Breathing in a Standing Position Using Dynamic Chest Radiography with a Flat Panel Detector System ("Dynamic X-Ray Phrenicography"): Initial Experience in 172 Volunteers.

    Science.gov (United States)

    Yamada, Yoshitake; Ueyama, Masako; Abe, Takehiko; Araki, Tetsuro; Abe, Takayuki; Nishino, Mizuki; Jinzaki, Masahiro; Hatabu, Hiroto; Kudoh, Shoji

    2017-04-01

    Diaphragmatic motion in a standing position during tidal breathing remains unclear. The purpose of this observational study was to evaluate diaphragmatic motion during tidal breathing in a standing position in a health screening center cohort using dynamic chest radiography in association with participants' demographic characteristics. One hundred seventy-two subjects (103 men; aged 56.3 ± 9.8 years) underwent sequential chest radiographs during tidal breathing using dynamic chest radiography with a flat panel detector system. We evaluated the excursions of and peak motion speeds of the diaphragms. Associations between the excursions and participants' demographics (gender, height, weight, body mass index [BMI], smoking history, tidal volume, vital capacity, and forced expiratory volume) were investigated. The average excursion of the left diaphragm (14.9 ± 4.6 mm, 95% CI 14.2-15.5 mm) was significantly larger than that of the right (11.0 ± 4.0 mm, 95% CI 10.4-11.6 mm) (P <0.001). The peak motion speed of the left diaphragm (inspiratory, 16.6 ± 4.2 mm/s; expiratory, 13.7 ± 4.2 mm/s) was significantly faster than that of the right (inspiratory, 12.4 ± 4.4 mm/s; expiratory, 9.4 ± 3.8 mm/s) (both P <0.001). Both simple and multiple regression models demonstrated that higher BMI and higher tidal volume were associated with increased excursions of the bilateral diaphragm (all P <0.05). The average excursions of the diaphragms are 11.0 mm (right) and 14.9 mm (left) during tidal breathing in a standing position. The diaphragmatic motion of the left is significantly larger and faster than that of the right. Higher BMI and tidal volume are associated with increased excursions of the bilateral diaphragm. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Paired maximum inspiratory and expiratory plain chest radiographs for assessment of airflow limitation in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Takashi, E-mail: tkino@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Kawayama, Tomotaka, E-mail: kawayama_tomotaka@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Imamura, Youhei, E-mail: mamura_youhei@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Sakazaki, Yuki, E-mail: sakazaki@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Hirai, Ryo, E-mail: hirai_ryou@kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Ishii, Hidenobu, E-mail: shii_hidenobu@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Suetomo, Masashi, E-mail: jin_t_f_c@yahoo.co.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Matsunaga, Kazuko, E-mail: kmatsunaga@kouhoukai.or.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Azuma, Koichi, E-mail: azuma@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan); Fujimoto, Kiminori, E-mail: kimichan@med.kurume-u.ac.jp [Department of Radiology, Kurume University School of Medicine, Kurume (Japan); Hoshino, Tomoaki, E-mail: hoshino@med.kurume-u.ac.jp [Division of Respirology, Neurology, and Rheumatology, Department of Medicine, Kurume University School of Medicine, Kurume (Japan)

    2015-04-15

    Highlights: •It is often to use computed tomography (CT) scan for diagnosis of chronic obstructive pulmonary disease. •CT scan is more expensive and higher. •A plane chest radiography more simple and cheap. Moreover, it is useful as detection of pulmonary emphysema, but not airflow limitation. •Our study demonstrated that the maximum inspiratory and expiratory plane chest radiography technique could detect severe airflow limitations. •We believe that the technique is helpful to diagnose the patients with chronic obstructive pulmonary disease. -- Abstract: Background: The usefulness of paired maximum inspiratory and expiratory (I/E) plain chest radiography (pCR) for diagnosis of chronic obstructive pulmonary disease (COPD) is still unclear. Objectives: We examined whether measurement of the I/E ratio using paired I/E pCR could be used for detection of airflow limitation in patients with COPD. Methods: Eighty patients with COPD (GOLD stage I = 23, stage II = 32, stage III = 15, stage IV = 10) and 34 control subjects were enrolled. The I/E ratios of frontal and lateral lung areas, and lung distance between the apex and base on pCR views were analyzed quantitatively. Pulmonary function parameters were measured at the same time. Results: The I/E ratios for the frontal lung area (1.25 ± 0.01), the lateral lung area (1.29 ± 0.01), and the lung distance (1.18 ± 0.01) were significantly (p < 0.05) reduced in COPD patients compared with controls (1.31 ± 0.02 and 1.38 ± 0.02, and 1.22 ± 0.01, respectively). The I/E ratios in frontal and lateral areas, and lung distance were significantly (p < 0.05) reduced in severe (GOLD stage III) and very severe (GOLD stage IV) COPD as compared to control subjects, although the I/E ratios did not differ significantly between severe and very severe COPD. Moreover, the I/E ratios were significantly correlated with pulmonary function parameters. Conclusions: Measurement of I/E ratios on paired I/E pCR is simple and

  17. Paired maximum inspiratory and expiratory plain chest radiographs for assessment of airflow limitation in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Kinoshita, Takashi; Kawayama, Tomotaka; Imamura, Youhei; Sakazaki, Yuki; Hirai, Ryo; Ishii, Hidenobu; Suetomo, Masashi; Matsunaga, Kazuko; Azuma, Koichi; Fujimoto, Kiminori; Hoshino, Tomoaki

    2015-01-01

    Highlights: •It is often to use computed tomography (CT) scan for diagnosis of chronic obstructive pulmonary disease. •CT scan is more expensive and higher. •A plane chest radiography more simple and cheap. Moreover, it is useful as detection of pulmonary emphysema, but not airflow limitation. •Our study demonstrated that the maximum inspiratory and expiratory plane chest radiography technique could detect severe airflow limitations. •We believe that the technique is helpful to diagnose the patients with chronic obstructive pulmonary disease. -- Abstract: Background: The usefulness of paired maximum inspiratory and expiratory (I/E) plain chest radiography (pCR) for diagnosis of chronic obstructive pulmonary disease (COPD) is still unclear. Objectives: We examined whether measurement of the I/E ratio using paired I/E pCR could be used for detection of airflow limitation in patients with COPD. Methods: Eighty patients with COPD (GOLD stage I = 23, stage II = 32, stage III = 15, stage IV = 10) and 34 control subjects were enrolled. The I/E ratios of frontal and lateral lung areas, and lung distance between the apex and base on pCR views were analyzed quantitatively. Pulmonary function parameters were measured at the same time. Results: The I/E ratios for the frontal lung area (1.25 ± 0.01), the lateral lung area (1.29 ± 0.01), and the lung distance (1.18 ± 0.01) were significantly (p < 0.05) reduced in COPD patients compared with controls (1.31 ± 0.02 and 1.38 ± 0.02, and 1.22 ± 0.01, respectively). The I/E ratios in frontal and lateral areas, and lung distance were significantly (p < 0.05) reduced in severe (GOLD stage III) and very severe (GOLD stage IV) COPD as compared to control subjects, although the I/E ratios did not differ significantly between severe and very severe COPD. Moreover, the I/E ratios were significantly correlated with pulmonary function parameters. Conclusions: Measurement of I/E ratios on paired I/E pCR is simple and

  18. Side-emitting fiber optic position sensor

    Science.gov (United States)

    Weiss, Jonathan D [Albuquerque, NM

    2008-02-12

    A side-emitting fiber optic position sensor and method of determining an unknown position of an object by using the sensor. In one embodiment, a concentrated beam of light source illuminates the side of a side-emitting fiber optic at an unknown axial position along the fiber's length. Some of this side-illuminated light is in-scattered into the fiber and captured. As the captured light is guided down the fiber, its intensity decreases due to loss from side-emission away from the fiber and from bulk absorption within the fiber. By measuring the intensity of light emitted from one (or both) ends of the fiber with a photodetector(s), the axial position of the light source is determined by comparing the photodetector's signal to a calibrated response curve, look-up table, or by using a mathematical model. Alternatively, the side-emitting fiber is illuminated at one end, while a photodetector measures the intensity of light emitted from the side of the fiber, at an unknown position. As the photodetector moves further away from the illuminated end, the detector's signal strength decreases due to loss from side-emission and/or bulk absorption. As before, the detector's signal is correlated to a unique position along the fiber.

  19. Effects of Ramadan Fasting on Spirometric Values and Clinical Symptoms in Asthmatic Patients

    Directory of Open Access Journals (Sweden)

    Abdolreza Norouzy

    2013-07-01

    Full Text Available Introduction: Ramadan is the 9th Islamic lunar month during which Muslims avoid eating and drinking from sunrise to sunset. The effect of Ramadan intermittent fasting on asthma control is controversial. The aim of this study was to investigate the effects of Ramadan fasting on the spirometric variables and clinical symptoms on well-controlled asthmatic patients during Ramadan. Material and Methods: a cohort study was conducted in Mashhad, Khorasan Razavi, Iran. Twenty-nine (19 females and 10 males well-controlled asthmatic patients aged 47 (12 years completed the study. The average duration of fasting was 26.5 days. Assessment of spirometric variables (daily peak expiratory flow, peak expiratory flow variability, peak expiratory flow home monitoring as well as asthma clinical symptoms including dyspnea, cough, wheezing, and chest tightness were carried out. Results: No significant changes in clinical symptoms were reported in asthmatic patients at the end of Ramadan fasting. Among spirometric variables, only peak expiratory flow improved after Ramadan (p <0.05. There was a reduction in the mean peak expiratory flow variability from 13% at the first week of fasting to 10% at the fourth week (p <0.05. Conclusion: In well-controlled asthmatic patients, Ramadan fasting resulted in improvement in peak expiratory flow and peak expiratory flow variability.

  20. The Effects of Ramadan Intermittent Fasting (RIF) on Spirometric Data of Stable COPD Patients: A Pilot Study.

    Science.gov (United States)

    Zouari, Hajer; Latiri, Imed; Mahjoub, Mohamed; Boussarsar, Mohamed; Benzarti, Mohamed; Abdelghani, Ahmed; Ben Saad, Helmi

    2018-03-01

    No previous study has raised the effects of RIF on lung function data of chronic obstructive pulmonary disease (COPD) patients. The objective of the present study was to assess the effects of RIF on spirometric data measured in male patients with a stable COPD. Sixteen patients with stable COPD (mean ± SD of age: 64 ± 7 years) who fasted during Ramadan volunteered to the study. Three sessions (Before-R, End-R, and After-R) were selected for spirometry tests that were consistently performed 2.5-4.5 hr before fasting break. Assessment sessions comprised: forced vital capacity (FVC), 1st s forced expiratory volume (FEV 1 ), FEV 1 /FVC, peak expiratory flow (PEF), maximal mid-expiratory flow (MMEF), and forced expiratory flow rate at the x% of FVC to be exhaled (FEFx%). A reversibility test was performed only during the Before-Ramadan session. Spirometric data were expressed in percentages of local reference values. Findings were analyzed by applying repeated measures analysis of variance. The mean ± SD of the postbronchodilator FEV 1 /FVC ratio and the FEV 1 were, respectively, 0.52 ± 0.14 and 48 ± 19%. The mean ± SD of FEV 1 (Before-R: 47 ± 19, End-R: 45 ± 18, After-R: 44 ± 19%), FVC (Before-R: 73 ± 18, End-R: 71 ± 16, After-R: 69 ± 17%), FEV 1 /FVC (Before-R: 67 ± 16, End-R: 66 ± 16, After-R: 65 ± 16%), PEF (Before-R: 46 ± 19, End-R: 47 ± 22, After-R: 45 ± 21%), MMEF (Before-R: 19 ± 10, End-R: 18 ± 8, After-R: 18 ± 9%), FEF 25% (Before-R: 16 ± 6, End-R: 16 ± 5, After-R: 15 ± 5%), FEF 50% (Before-R: 21 ± 14, End-R: 20 ± 12, After-R: 20 ± 12%) and FEF 75% (Before-R: 27 ± 19, End-R: 27 ± 19, After-R: 27 ± 19%) were not significantly influenced by RIF. RIF did not bring about any significant changes in the spirometric data of stable COPD male patients fasting the 2016 holy month of Ramadan.

  1. Effects of non-fatiguing respiratory muscle loading induced by expiratory flow limitation during strenuous incremental cycle exercise on metabolic stress and circulating natural killer cells.

    Science.gov (United States)

    Rolland-Debord, Camille; Morelot-Panzini, Capucine; Similowski, Thomas; Duranti, Roberto; Laveneziana, Pierantonio

    2017-12-01

    Exercise induces release of cytokines and increase of circulating natural killers (NK) lymphocyte during strong activation of respiratory muscles. We hypothesised that non-fatiguing respiratory muscle loading during exercise causes an increase in NK cells and in metabolic stress indices. Heart rate (HR), ventilation (VE), oesophageal pressure (Pes), oxygen consumption (VO 2 ), dyspnoea and leg effort were measured in eight healthy humans (five men and three women, average age of 31 ± 4 years and body weight of 68 ± 10 kg), performing an incremental exercise testing on a cycle ergometer under control condition and expiratory flow limitation (FL) achieved by putting a Starling resistor. Blood samples were obtained at baseline, at peak of exercise and at iso-workload corresponding to that reached at the peak of FL exercise during control exercise. Diaphragmatic fatigue was evaluated by measuring the tension time index of the diaphragm. Respiratory muscle overloading caused an earlier interruption of exercise. Diaphragmatic fatigue did not occur in the two conditions. At peak of flow-limited exercise compared to iso-workload, HR, peak inspiratory and expiratory Pes, NK cells and norepinephrine were significantly higher. The number of NK cells was significantly related to ΔPes (i.e. difference between the most and the less negative Pes) and plasmatic catecholamines. Loading of respiratory muscles is able to cause an increase of NK cells provided that activation of respiratory muscles is intense enough to induce a significant metabolic stress.

  2. Variable Ventilation Improved Respiratory System Mechanics and Ameliorated Pulmonary Damage in a Rat Model of Lung Ischemia-Reperfusion.

    Science.gov (United States)

    Soluri-Martins, André; Moraes, Lillian; Santos, Raquel S; Santos, Cintia L; Huhle, Robert; Capelozzi, Vera L; Pelosi, Paolo; Silva, Pedro L; de Abreu, Marcelo Gama; Rocco, Patricia R M

    2017-01-01

    Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV) has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV) in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1) ischemia-reperfusion (IR), in which the left pulmonary hilum was completely occluded and released after 30 min; and (2) Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured) and right (contralateral) lungs from 6 animals per group were removed, and served as non-ventilated group (NV) for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV ( n = 6/group) [tidal volume (V T ) = 6 mL/kg, positive end-expiratory pressure (PEEP) = 2 cmH 2 O, fraction of inspired oxygen (FiO 2 ) = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated V T values ( n = 1200; mean V T = 6 mL/kg), with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final), respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH 2 0/ml and 2.0 ± 0.8 cmH 2 0/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9-33.1] and VV 5.4% [3.1-8.8], p = 0.04, respectively). In left lungs of IR animals, VCV increased the expression of interleukin-6 and

  3. Variable Ventilation Improved Respiratory System Mechanics and Ameliorated Pulmonary Damage in a Rat Model of Lung Ischemia-Reperfusion

    Directory of Open Access Journals (Sweden)

    Patricia R. M. Rocco

    2017-05-01

    Full Text Available Lung ischemia-reperfusion injury remains a major complication after lung transplantation. Variable ventilation (VV has been shown to improve respiratory function and reduce pulmonary histological damage compared to protective volume-controlled ventilation (VCV in different models of lung injury induced by endotoxin, surfactant depletion by saline lavage, and hydrochloric acid. However, no study has compared the biological impact of VV vs. VCV in lung ischemia-reperfusion injury, which has a complex pathophysiology different from that of other experimental models. Thirty-six animals were randomly assigned to one of two groups: (1 ischemia-reperfusion (IR, in which the left pulmonary hilum was completely occluded and released after 30 min; and (2 Sham, in which animals underwent the same surgical manipulation but without hilar clamping. Immediately after surgery, the left (IR-injured and right (contralateral lungs from 6 animals per group were removed, and served as non-ventilated group (NV for molecular biology analysis. IR and Sham groups were further randomized to one of two ventilation strategies: VCV (n = 6/group [tidal volume (VT = 6 mL/kg, positive end-expiratory pressure (PEEP = 2 cmH2O, fraction of inspired oxygen (FiO2 = 0.4]; or VV, which was applied on a breath-to-breath basis as a sequence of randomly generated VT values (n = 1200; mean VT = 6 mL/kg, with a 30% coefficient of variation. After 5 min of ventilation and at the end of a 2-h period (Final, respiratory system mechanics and arterial blood gases were measured. At Final, lungs were removed for histological and molecular biology analyses. Respiratory system elastance and alveolar collapse were lower in VCV than VV (mean ± SD, VCV 3.6 ± 1.3 cmH20/ml and 2.0 ± 0.8 cmH20/ml, p = 0.005; median [interquartile range], VCV 20.4% [7.9–33.1] and VV 5.4% [3.1–8.8], p = 0.04, respectively. In left lungs of IR animals, VCV increased the expression of interleukin-6 and intercellular

  4. A bench study of intensive-care-unit ventilators: new versus old and turbine-based versus compressed gas-based ventilators

    Science.gov (United States)

    Thille, Arnaud W.; Lyazidi, Aissam; Richard, Jean-Christophe M.; Galia, Fabrice; Brochard, Laurent

    2009-01-01

    Objective To compare 13 commercially available, new-generation, intensive-care-unit (ICU) ventilators regarding trigger function, pressurization capacity during pressure-support ventilation (PSV), accuracy of pressure measurements and expiratory resistance. Design and Setting Bench study at a research laboratory in a university hospital. Material Four turbine-based ventilators and nine conventional servo-valve compressed-gas ventilators were tested using a two-compartment lung model. Results Three levels of effort were simulated. Each ventilator was evaluated at four PSV levels (5, 10, 15, and 20 cm H2O), with and without positive end-expiratory pressure (5 cm H2O, Trigger function was assessed as the time from effort onset to detectable pressurization. Pressurization capacity was evaluated using the airway pressure-time product computed as the net area under the pressure-time curve over the first 0.3 s after inspiratory effort onset. Expiratory resistance was evaluated by measuring trapped volume in controlled ventilation. Significant differences were found across the ventilators, with a range of triggering-delay from 42 ms to 88 ms for all conditions averaged (Pventilators at PSV5 and three at PSV10, suggesting an inability to unload patient’s effort. On average, turbine-based ventilators performed better than conventional ventilators, which showed no improvement compared to a 2000 bench comparison. Conclusion Technical performances of trigger function, pressurization capacity and expiratory resistance vary considerably across new-generation ICU ventilators. ICU ventilators seem to have reached a technical ceiling in recent years, and some ventilators still perform inadequately. PMID:19352622

  5. Avaliação das modalidades ventilatórias no período transoperatório por meio de questionário Evaluación de las modalidades ventilatorias en el período transoperatorio por medio de cuestionario Evaluation of transoperatory ventilation modalities by a questionnaire

    Directory of Open Access Journals (Sweden)

    Angel Soubhie

    2010-08-01

    27 preguntas objetivas, se aplicó a un grupo compuesto por médicos anestesiólogos y en especialización que actúan en diferentes hospitales privados en la ciudad de São Paulo. Los cuestionarios se aplicaron en un período de 15 días. Se observaron los estándares ventilatorios, la presión positiva al final de la expiración (PEEP, el reclutamiento alveolar y el cálculo del volumen corriente que se usó con intubación traqueal. RESULTADOS: Los participantes fueron predominantemente del sexo masculino, un 40,5% con título superior en Anestesiología (TSA, y la mayoría que terminó la especialización hace menos de 10 años. La mayor parte de los anestesiólogos utiliza el PEEP como rutina, entre 5 y 10 cmH2O. Gran parte de los anestesiólogos todavía usa el flujo de gases frescos por encima de 1000 mL.min-1. Las maniobras de reclutamiento alveolar son hechas por un 80% de los entrevistados después de la intubación y antes de la retirada de los tubos, siendo la estrategia más común la insuflación con 40 cmH2O por 15 segundos. En cuanto a las estrategias protectoras de ventilación, apenas 30% utilizan volumen corriente BACKGROUND AND OBJECTIVES: Anesthesia devices have been making it possible to reduce the physiological repercussions and problems caused by mechanical ventilation. The objective of this study was to evaluate, retrospectively, ventilatory methods and support resources used by a group of anesthesiologists in patients without prior lung damage in the intraoperative period. METHODS: A non-identifiable questionnaire composed of 27 questions was applied to a group of anesthesiologists and anesthesiology residents who work at different private hospitals in the city of São Paulo. The questionnaires were applied over a 15-day period. Ventilation patterns, positive end-expiratory pressure (PEEP, alveolar recruitment maneuvers, and the calculation of the tidal volume used with tracheal intubation were observed. RESULTS: Participants were

  6. Hypothermic total liquid ventilation after experimental aspiration-associated acute respiratory distress syndrome.

    Science.gov (United States)

    Rambaud, Jérôme; Lidouren, Fanny; Sage, Michaël; Kohlhauer, Matthias; Nadeau, Mathieu; Fortin-Pellerin, Étienne; Micheau, Philippe; Zilberstein, Luca; Mongardon, Nicolas; Ricard, Jean-Damien; Terada, Megumi; Bruneval, Patrick; Berdeaux, Alain; Ghaleh, Bijan; Walti, Hervé; Tissier, Renaud

    2018-05-02

    Ultrafast cooling by total liquid ventilation (TLV) provides potent cardio- and neuroprotection after experimental cardiac arrest. However, this was evaluated in animals with no initial lung injury, whereas out-of-hospital cardiac arrest is frequently associated with early-onset pneumonia, which may lead to acute respiratory distress syndrome (ARDS). Here, our objective was to determine whether hypothermic TLV could be safe or even beneficial in an aspiration-associated ARDS animal model. ARDS was induced in anesthetized rabbits through a two-hits model including the intra-tracheal administration of a pH = 1 solution mimicking gastric content and subsequent gaseous non-protective ventilation during 90 min (tidal volume [Vt] = 10 ml/kg with positive end-expiration pressure [PEEP] = 0 cmH 2 O). After this initial period, animals either received lung protective gas ventilation (LPV; Vt = 8 ml/kg and PEEP = 5 cmH 2 O) under normothermic conditions, or hypothermic TLV (TLV; Vt = 8 ml/kg and end-expiratory volume = 15 ml/kg). Both strategies were applied for 120 min with a continuous monitoring of respiratory and cardiovascular parameters. Animals were then euthanized for pulmonary histological analyses. Eight rabbits were included in each group. Before randomization, all animals elicited ARDS with arterial oxygen partial pressure over inhaled oxygen fraction ratios (PaO 2 /FiO 2 ) below 100 mmHg, as well as decreased lung compliance. After randomization, body temperature rapidly decreased in TLV versus LPV group (32.6 ± 0.6 vs. 38.2 ± 0.4 °C after 15 min). Static lung compliance and gas exchanges were not significantly different in the TLV versus LPV group (PaO 2 /FiO 2  = 62 ± 4 vs. 52 ± 8 mmHg at the end of the procedure, respectively). Mean arterial pressure and arterial bicarbonates levels were significantly higher in TLV versus LPV. Histological analysis also showed significantly lower inflammation in

  7. End-Users, Front Ends and Librarians.

    Science.gov (United States)

    Bourne, Donna E.

    1989-01-01

    The increase in end-user searching, the advantages and limitations of front ends, and the role of the librarian in end-user searching are discussed. It is argued that librarians need to recognize that front ends can be of benefit to themselves and patrons, and to assume the role of advisors and educators for end-users. (37 references) (CLB)

  8. An alternate end design for SSC dipoles

    International Nuclear Information System (INIS)

    Peters, C.; Caspi, S.; Taylor, C.

    1989-02-01

    Experience in the SSC dipole program has shown that fabrication of cylindrical coil ends is difficult. Cable stiffness requires large forces to maintain the proper position of the conductors in the end during winding. After winding, the coil ends remain distorted nd significant motion of the need conductors is required to force the coil end into the molding cavity. Local mechanical stresses are high during this process and extra pieces of insulation are required to prevent turn-to-turn shorts from developing during the winding and molding steps. Prior to assembly the coil end is compressed in a mold cavity and injected with a filler material to correct surface irregularities and fill voids in the end. LBL has developed an alternate design which permits the conductors to be wound over the end using minimal force and technician coerosion. The conductors are placed on a conical surface where the largest diameter over the outer layer conductors is 10 cm. No coil end spaces or insulation pieces between turns are required. The conductor geometry was analytically optimized to meet SSC multipole requirements for the ends. The first 1-m dipole utilizing this end geometry has been constructed and successfully tested. Design and construction data are presented. Also model test results, including training and multipole measurements of the end are given. 1 ref., 12 figs., 3 tabs

  9. Coordinated joint motion control system with position error correction

    Science.gov (United States)

    Danko, George L.

    2016-04-05

    Disclosed are an articulated hydraulic machine supporting, control system and control method for same. The articulated hydraulic machine has an end effector for performing useful work. The control system is capable of controlling the end effector for automated movement along a preselected trajectory. The control system has a position error correction system to correct discrepancies between an actual end effector trajectory and a desired end effector trajectory. The correction system can employ one or more absolute position signals provided by one or more acceleration sensors supported by one or more movable machine elements. Good trajectory positioning and repeatability can be obtained. A two joystick controller system is enabled, which can in some cases facilitate the operator's task and enhance their work quality and productivity.

  10. End-to-End Airplane Detection Using Transfer Learning in Remote Sensing Images

    Directory of Open Access Journals (Sweden)

    Zhong Chen

    2018-01-01

    Full Text Available Airplane detection in remote sensing images remains a challenging problem due to the complexity of backgrounds. In recent years, with the development of deep learning, object detection has also obtained great breakthroughs. For object detection tasks in natural images, such as the PASCAL (Pattern Analysis, Statistical Modelling and Computational Learning VOC (Visual Object Classes Challenge, the major trend of current development is to use a large amount of labeled classification data to pre-train the deep neural network as a base network, and then use a small amount of annotated detection data to fine-tune the network for detection. In this paper, we use object detection technology based on deep learning for airplane detection in remote sensing images. In addition to using some characteristics of remote sensing images, some new data augmentation techniques have been proposed. We also use transfer learning and adopt a single deep convolutional neural network and limited training samples to implement end-to-end trainable airplane detection. Classification and positioning are no longer divided into multistage tasks; end-to-end detection attempts to combine them for optimization, which ensures an optimal solution for the final stage. In our experiment, we use remote sensing images of airports collected from Google Earth. The experimental results show that the proposed algorithm is highly accurate and meaningful for remote sensing object detection.

  11. Respiratory mechanics to understand ARDS and guide mechanical ventilation.

    Science.gov (United States)

    Mauri, Tommaso; Lazzeri, Marta; Bellani, Giacomo; Zanella, Alberto; Grasselli, Giacomo

    2017-11-30

    As precision medicine is becoming a standard of care in selecting tailored rather than average treatments, physiological measurements might represent the first step in applying personalized therapy in the intensive care unit (ICU). A systematic assessment of respiratory mechanics in patients with the acute respiratory distress syndrome (ARDS) could represent a step in this direction, for two main reasons. Approach and Main results: On the one hand, respiratory mechanics are a powerful physiological method to understand the severity of this syndrome in each single patient. Decreased respiratory system compliance, for example, is associated with low end expiratory lung volume and more severe lung injury. On the other hand, respiratory mechanics might guide protective mechanical ventilation settings. Improved gravitationally dependent regional lung compliance could support the selection of positive end-expiratory pressure and maximize alveolar recruitment. Moreover, the association between driving airway pressure and mortality in ARDS patients potentially underlines the importance of sizing tidal volume on respiratory system compliance rather than on predicted body weight. The present review article aims to describe the main alterations of respiratory mechanics in ARDS as a potent bedside tool to understand severity and guide mechanical ventilation settings, thus representing a readily available clinical resource for ICU physicians.

  12. Assembling the CMS yoke end-caps

    CERN Multimedia

    Laurent Guiraud

    2001-01-01

    A crane is used to piece together one of the end-caps that will provide the path for magnetic flux return on the CMS experiment. A total of six end-cap discs will be assembled before being positioned on the barrel yoke to complete the huge 12 500 tonne cylinder yoke. The magnetic field produced will be greater than any other solenoid created to date at 4 T, 100 000 times greater than the Earth's natural magnetic field, and will store enough energy to melt 18 tonnes of gold.

  13. Calculation of the capnographic index based on expiratory molar mass-volume-curves--a suitable tool to screen for cystic fibrosis lung disease.

    Science.gov (United States)

    Fuchs, Susanne I; Junge, Sibylle; Ellemunter, Helmut; Ballmann, Manfred; Gappa, Monika

    2013-05-01

    Volumetric capnography reflecting the course of CO2-exhalation is used to assess ventilation inhomogeneity. Calculation of the slope of expiratory phase 3 and the capnographic index (KPIv) from expirograms allows quantification of extent and severity of small airway impairment. However, technical limitations have hampered more widespread use of this technique. Using expiratory molar mass-volume-curves sampled with a handheld ultrasonic flow sensor during tidal breathing is a novel approach to extract similar information from expirograms in a simpler manner possibly qualifying as a screening tool for clinical routine. The aim of the present study was to evaluate calculation of the KPIv based on molar mass-volume-curves sampled with an ultrasonic flow sensor in patients with CF and controls by assessing feasibility, reproducibility and comparability with the Lung Clearance Index (LCI) derived from multiple breath washout (MBW) used as the reference method. Measurements were performed in patients with CF and healthy controls during a single test occasion using the EasyOne Pro, MBW Module (ndd Medical Technologies, Switzerland). Capnography and MBW were performed in 87/96 patients with CF and 38/42 controls, with a success rate of 90.6% for capnography. Mean age (range) was 12.1 (4-25) years. Mean (SD) KPIv was 6.94 (3.08) in CF and 5.10 (2.06) in controls (p=0.001). Mean LCI (SD) was 8.0 (1.4) in CF and 6.2 (0.4) in controls (p=molar mass-volume-curves is feasible. KPIv is significantly different between patients with CF and controls and correlates with the LCI. However, individual data revealed a relevant overlap between patients and controls requiring further evaluation, before this method can be recommended for clinical use. Copyright © 2012 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  14. End-to-End Beam Simulations for the New Muon G-2 Experiment at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Korostelev, Maxim [Cockcroft Inst. Accel. Sci. Tech.; Bailey, Ian [Lancaster U.; Herrod, Alexander [Liverpool U.; Morgan, James [Fermilab; Morse, William [RIKEN BNL; Stratakis, Diktys [RIKEN BNL; Tishchenko, Vladimir [RIKEN BNL; Wolski, Andrzej [Cockcroft Inst. Accel. Sci. Tech.

    2016-06-01

    The aim of the new muon g-2 experiment at Fermilab is to measure the anomalous magnetic moment of the muon with an unprecedented uncertainty of 140 ppb. A beam of positive muons required for the experiment is created by pion decay. Detailed studies of the beam dynamics and spin polarization of the muons are important to predict systematic uncertainties in the experiment. In this paper, we present the results of beam simulations and spin tracking from the pion production target to the muon storage ring. The end-to-end beam simulations are developed in Bmad and include the processes of particle decay, collimation (with accurate representation of all apertures) and spin tracking.

  15. The longitudinal relationship of work stress with peak expiratory flow: a cohort study.

    Science.gov (United States)

    Loerbroks, Adrian; Karrasch, Stefan; Lunau, Thorsten

    2017-10-01

    Research has suggested that psychological stress is associated with reduced lung function and with the development of respiratory disease. Among the major potential sources of stress in adulthood are working conditions. We aimed to examine the relationship of work stress with lung function. We drew on 4-year prospective data from the Survey of Health, Ageing and Retirement in Europe. The analyzed sample comprised 2627 workers aged 50 years or older who were anamnestically free of respiratory disease. Work stress at baseline was operationalized by abbreviated instruments measuring the well-established effort-reward imbalance model (seven items) and the control component of the job-demand control (two items). Peak expiratory flow (PEF) was determined at baseline and at follow-up. Continuous and categorized (i.e., by the tertile) work stress variables were employed in multivariable linear regression models to predict PEF change. Work stress did not show statistically significant associations with PEF change. For instance, the unstandardized regression coefficient for PEF decline according to high versus low effort-reward imbalance was -1.41 (95% confidence interval = -3.75, 0.94). Our study is the first to examine prospective relationships between work stress and PEF. Overall, we did not observe meaningful associations. Future studies should consider a broader spectrum of spirometric parameters and should expand research to younger and possibly less-selected working populations (i.e., aged <50 years).

  16. Modelling axisymmetric cod-ends made of different mesh types

    DEFF Research Database (Denmark)

    Priour, D.; Herrmann, Bent; O'Neill, F.G.

    2009-01-01

    the selectivity process has become more important. This paper presents a model of the deformation of an axisymmetric cod-end. The twine tension and the catch pressure acting on the knots of each mesh along the cod-end profile are calculated, and a Newton-Raphson scheme is used to estimate the equilibrium position...

  17. End to End Travel

    Data.gov (United States)

    US Agency for International Development — E2 Solutions is a web based end-to-end travel management tool that includes paperless travel authorization and voucher document submissions, document approval...

  18. Peeping thread from a laparotomy scar: Misery of an old man

    Directory of Open Access Journals (Sweden)

    Ramesh Aggarwal

    2012-01-01

    Full Text Available Despite availability of modern methods of various surgical techniques for treating complicated patients, there are still some unreported incidents in day to day practice where simple surgical procedure ends up in unwanted complications. This may be attributed sometimes to the negligence of treating doctors and sometime to the patient himself. We present here one such case where unnecessary morbidity added to the patient after surgery.

  19. PROGRESSIVE MUSCLE RELAXATION INCREASE PEAK EXPIRATORY FLOW RATE ON CHRONIC OBSTRUCTIVE PULMONARY DISEASE PATIENTS

    Directory of Open Access Journals (Sweden)

    Tintin Sukartini

    2017-07-01

    Full Text Available Introduction: Limited progressive air flow in Chronic Obstructive Pulmonary Disease (COPD can caused by small airway disease (bronchiolitis obstructive and loss of elasticity of the lung (emphysema. Further it can be decreasing the quality of life in COPD patients because dyspnea and uncomfortable in activity. Progressive muscle relaxation (PMR is one of the relaxation technique that can repair pulmonary ventilation by decreasing chronic constriction of the respiratory muscles. The objective of this study was to analyze the effect of progressive muscle relaxation on raised peak expiratory flow rate (PEFR. Method: A pre-experimental one group pre-post test design was used in this study. Population was all of the COPD patients at Pulmonary Specialist Polyclinic Dr Mohamad Soewandhie Surabaya. There were 8 respondents taken by using purposive sampling. PEFR was counted by using peak flow meter every six day. Data were analyzed by using Paired t-Test with significance level  p≤0.05. Result: The result showed that PMR had significance level on increasing of PEFR (p=0.012. Discussion: It can be concluded that PMR has an effect on raise PEFR. Further studies are recommended to measure the effect of PMR on respiratory rate (RR, heart rate (HR subjective dyspnoe symptoms, forced expiration volume on the first minute (FEV1 and mid maximum flow rate (MMFR in COPD patients.

  20. Accuracy of automatic tube compensation in new-generation mechanical ventilators.

    Science.gov (United States)

    Elsasser, Serge; Guttmann, Josef; Stocker, Reto; Mols, Georg; Priebe, Hans-Joachim; Haberthür, Christoph

    2003-11-01

    To compare performance of flow-adapted compensation of endotracheal tube resistance (automatic tube compensation, ATC) between the original ATC system and ATC systems incorporated in commercially available ventilators. Bench study. University research laboratory. The original ATC system, Dräger Evita 2 prototype, Dräger Evita 4, Puritan-Bennett 840. The four ventilators under investigation were alternatively connected via different sized endotracheal tubes and an artificial trachea to an active lung model. Test conditions consisted of two ventilatory modes (ATC vs. continuous positive airway pressure), three different sized endotracheal tubes (inner diameter 7.0, 8.0, and 9.0 mm), two ventilatory rates (15/min and 30/min), and four levels of positive end-expiratory pressure (0, 5, 10, and 15 cm H2O). Performance of tube compensation was assessed by the amount of tube-related (additional) work of breathing (WOBadd), which was calculated on the basis of pressure gradient across the endotracheal tube. Compared with continuous positive airway pressure, ATC reduced inspiratory WOBadd by 58%, 68%, 50%, and 97% when using the Evita 4, the Evita 2 prototype, the Puritan-Bennett 840, and the original ATC system, respectively. Depending on endotracheal tube diameter and ventilatory pattern, inspiratory WOBadd was 0.12-5.2 J/L with the original ATC system, 1.5-28.9 J/L with the Puritan-Bennett 840, 10.4-21.0 J/L with the Evita 2 prototype, and 10.1-36.1 J/L with the Evita 4 (difference between each ventilator at identical test situations, p ventilator (p <.025). Flow-adapted tube compensation by the original ATC system significantly reduced tube-related inspiratory and expiratory work of breathing. The commercially available ATC modes investigated here may be adequate for inspiratory but probably not for expiratory tube compensation.

  1. End-to-side and end-to-end anastomoses give similar results in cervical oesophagogastrostomy.

    Science.gov (United States)

    Pierie, J P; De Graaf, P W; Poen, H; Van Der Tweel, I; Obertop, H

    1995-12-01

    To find out if there were any differences in healing between end-to-end and end-to-side anastomoses for oesophagogastrostomy. Open study with historical controls. University hospital, The Netherlands. 28 patients with end-to-end and 90 patients with end-to-side anastomoses after transhiatal oesophagectomy and partial gastrectomy for cancer of the oesophagus or oesophagogastric junction, with gastric tube reconstruction and cervical anastomosis. Leak and stricture rates, and the number of dilatations needed to relieve dysphagia. There were no significant differences in leak rates (end-to-end 4/28, 14%, and end-to-side 13/90, 14%) or anastomotic strictures (end-to-end 9/28, 32%, and end-to-side 26/90, 29%). The median number of dilatations needed to relieve dysphagia was 7 (1-33) after end-to-end and 9 (1-113) after end-to-side oesophagogastrostomy. There were no differences between the two methods of suture of cervical oesophagogastrostomy when leakage, stricture, and number of dilatations were used as criteria of good healing.

  2. Tidal volume delivery from ICU ventilators at BTPS conditions: a bench study.

    Science.gov (United States)

    Duchateau, Paul; Guérin, Claude

    2013-04-01

    Even though it is not a common practice, an external filter to the expiratory limb of the breathing circuit may protect the expiratory valve from water saturation in case of nebulization, or from the environment in case of lung infection with multi-drug-resistant micro-organisms or H1N1 influenza. We added an external filter to the expiratory limb and measured tidal volume (VT) from 6 ICU ventilators: 2 with built-in expiratory filter (Avea, Puritan Bennett 840), and 4 without (Engström Carestation, Evita XL, Evita V500, and Servo-i), set in volume controlled mode, at BTPS (body temperature and pressure saturated) condition, with a heated humidifier and a lung model (compliance 16 mL/cm H2O, resistance 20 cm H2O/L/s) placed inside a neonatal incubator. The temperature was targeted at 37°C for both the heated humidifier and the incubator. The setup was run continuously for 24 hours. In the latter 4 ICU ventilators, a Hygrobac or Sterivent S external filter was placed upstream from the expiratory valve for an additional 24-hour period for each. At the end of this period, VT was measured at 4 nominal VT values (300, 400, 500, and 800 mL) with a pneumotachograph. The volume error computed from the ratio of set to measured VT (% set VT) was the primary end point. In these warm and wet conditions, volume error averaged 96 ± 3% for Avea, 100 ± 7% for Puritan Bennett 840, 90 ± 2% for Evita XL, 100 ± 7% for Evita V500, 105 ± 2% for Servo-i, and 108 ± 4% for Engström Carestation (P ventilators for VT delivery, with further significant changes occurring after addition of a filter at the distal expiratory limb.

  3. Poignancy: Mixed Emotional Experience in the Face of Meaningful Endings

    Science.gov (United States)

    Ersner-Hershfield, Hal; Mikels, Joseph A.; Sullivan, Sarah J.; Carstensen, Laura L.

    2009-01-01

    The experience of mixed emotions increases with age. Socioemotional selectivity theory suggests that mixed emotions are associated with shifting time horizons. Theoretically, perceived constraints on future time increase appreciation for life, which, in turn, elicits positive emotions such as happiness. Yet, the very same temporal constraints heighten awareness that these positive experiences come to an end, thus yielding mixed emotional states. In 2 studies, the authors examined the link between the awareness of anticipated endings and mixed emotional experience. In Study 1, participants repeatedly imagined being in a meaningful location. Participants in the experimental condition imagined being in the meaningful location for the final time. Only participants who imagined “last times” at meaningful locations experienced more mixed emotions. In Study 2, college seniors reported their emotions on graduation day. Mixed emotions were higher when participants were reminded of the ending that they were experiencing. Findings suggest that poignancy is an emotional experience associated with meaningful endings. PMID:18179325

  4. Positive solutions for a fourth order boundary value problem

    Directory of Open Access Journals (Sweden)

    Bo Yang

    2005-02-01

    Full Text Available We consider a boundary value problem for the beam equation, in which the boundary conditions mean that the beam is embedded at one end and free at the other end. Some new estimates to the positive solutions to the boundary value problem are obtained. Some sufficient conditions for the existence of at least one positive solution for the boundary value problem are established. An example is given at the end of the paper to illustrate the main results.

  5. Society of Behavioral Medicine's (SBM) position on emerging policy issues regarding electronic nicotine delivery systems (ENDS): A need for regulation.

    Science.gov (United States)

    Rojewski, Alana M; Coleman, Nortorious; Toll, Benjamin A

    2016-09-01

    Electronic nicotine delivery systems (ENDS), commonly known as electronic cigarettes (or e-cigarettes), are widely available in the USA, yet almost entirely unregulated on a national level. Researchers are currently gathering data to understand the individual and public health effects of ENDS, as well as the role that ENDS may play in tobacco treatment. Given these uncertainties, regulatory efforts should be aimed at understanding and minimizing any potential harms of ENDS. The Society of Behavioral Medicine (SBM) supports stronger regulation of ENDS, incorporation of ENDS into clean air policies, and special consideration of safety standards to protect vulnerable populations. SBM also supports research on ENDS to guide policy decisions.

  6. Performance characteristics of seven bilevel mechanical ventilators in pressure-support mode with different cycling criteria: a comparative bench study.

    Science.gov (United States)

    Chen, Yuqing; Cheng, Kewen; Zhou, Xin

    2015-01-26

    Pressure support ventilation from a bilevel device is a standard technique for non-invasive home ventilation. A bench study was designed to compare the performance and patient-ventilator synchronization of 7 bilevel ventilators, in the presence of system leaks. Ventilators were connected to a Hans Rudolph Series 1101 lung simulator (compliance, 50 mL/cmH2O; expiratory resistance, 20 cmH2O/L/s; respiratory rate, 15 breaths/min; inspiratory time, 1.0 s). All ventilators were set at 15 cmH2O pressure support and 5 cmH2O positive end-expiratory pressure. Tests were conducted at 2 system leaks (12-15 and 25-28 L/min). The performance characteristics and patient-ventilator asynchrony were assessed, including flow, airway pressure, time, and workload. The Breas Vivo30 could not synchronize with the simulator (frequent auto-triggering) at a leak of 25-28 L/min, but provided stable assisted ventilation when the leak was 12-15 L/min. Missed efforts and back-up ventilation occurred for the Weinmann VENTImotion and Airox Smartair Plus, requiring adjustment of trigger effort. All ventilators had a short trigger delay time (ventilators, possibly due to software algorithm differences. Adjusting the cycling criteria settings can alter the shape of the inspiratory phase and peak expiratory flow, and improve patient-ventilator synchrony.

  7. A randomized comparison of different ventilator strategies during thoracotomy for pulmonary resection.

    Science.gov (United States)

    Maslow, Andrew D; Stafford, Todd S; Davignon, Kristopher R; Ng, Thomas

    2013-07-01

    Protective lung ventilation is reported to benefit patients with acute respiratory distress syndrome. It is not known whether protective lung ventilation is also beneficial to patients undergoing single-lung ventilation for elective pulmonary resection. In an institutional review board-approved prospective randomized trial, 34 patients undergoing elective pulmonary resection requiring single-lung ventilation were enrolled. Informed consent was obtained. Patients were randomized to 1 of 2 groups: (1) high tidal volume (Hi-TV) of 10 mL/kg, rate of 7 breaths/min, and zero positive end-expiratory pressure or (2) low tidal volume (Lo-TV) of 5 mL/kg, rate of 14 breaths/min, and 5 cmH2O positive end-expiratory pressure. Ventilator settings were continued during both double- and single-lung ventilation. Pulmonary functions, hemodynamics, and postoperative outcomes were recorded. Patient demographics, operative characteristics, intraoperative hemodynamics, and postoperative pain and sedation scores were similar between the 2 groups. During most time periods, airway pressures (peak and plateau) were significantly higher in the Hi-TV group; however, plateau pressures remained less than 30 cmH2O at all times for all patients. The Hi-TV group had significantly lower arterial carbon dioxide tension, less arterial carbon dioxide tension-end-tidal carbon dioxide gradient, lower alveolar dead space ratio, and higher dynamic pulmonary compliance. There were no differences in postoperative morbidity and hospital days between the 2 groups, but atelectasis scores on postoperative days 1 and 2 were lower in the Hi-TV group. The use of Hi-TV during single-lung ventilation for pulmonary resection resulted in no increase in morbidity and was associated with less hypercarbia, less dead space ventilation, better dynamic compliance, and less postoperative atelectasis. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  8. Minimum concentrations of NO/sub 2/ causing acute effects on the respiratory gas exchange and airway-resistance in patients with chronic bronchitis

    Energy Technology Data Exchange (ETDEWEB)

    von Nieding, G; Wagner, M; Krekeler, H; Smidt, U; Muysers, K

    1971-01-01

    Nitrogen dioxide-air mixtures containing 0.5 to 5.0 ppM NO/sub 2/ were inhaled by 88 patients with chronic bronchitis over a 15-minute period for a total of 30 breaths during studies investigating the effects of the gas on airway resistance and respiratory gas exchange. End-expiratory oxygen pressures remained nearly constant during inhalation of 4 or 5 ppM NO/sub 2/, though significant decreases in arterial oxygen pressure accompanied by increases in end-expiratory-arterial oxygen pressure difference occurred. Inhalation of 2 ppM NO/sub 2/ did not decrease arterial oxygen pressure. Airway resistances increased significantly down to 1.5 ppM NO/sub 2/ concentrations. Lower concentrations caused no significant effects.

  9. Standardizing an End-to-end Accounting Service

    Science.gov (United States)

    Greenberg, Edward; Kazz, Greg

    2006-01-01

    Currently there are no space system standards available for space agencies to accomplish end-to-end accounting. Such a standard does not exist for spacecraft operations nor for tracing the relationship between the mission planning activities, the command sequences designed to perform those activities, the commands formulated to initiate those activities and the mission data and specifically the mission data products created by those activities. In order for space agencies to cross-support one another for data accountability/data tracing and for inter agency spacecraft to interoperate with each other, an international CCSDS standard for end-to-end data accountability/tracing needs to be developed. We will first describe the end-to-end accounting service model and functionality that supports the service. This model will describe how science plans that are ultimately transformed into commands can be associated with the telemetry products generated as a result of their execution. Moreover, the interaction between end-to-end accounting and service management will be explored. Finally, we will show how the standard end-to-end accounting service can be applied to a real life flight project i.e., the Mars Reconnaissance Orbiter project.

  10. Visual Alphabets: Video classification by end users

    NARCIS (Netherlands)

    Israël, Menno; van den Broek, Egon; van der Putten, Peter; den Uyl, Marten J.; Petrushin, Valery A.; Khan, Latifur

    2007-01-01

    The work presented here introduces a real-time automatic scene classifier within content-based video retrieval. In our envisioned approach end users like documentalists, not image processing experts, build classifiers interactively, by simply indicating positive examples of a scene. Classification

  11. Robotic end-effector for rewaterproofing shuttle tiles

    Science.gov (United States)

    Manouchehri, Davoud; Hansen, Joseph M.; Wu, Cheng M.; Yamamoto, Brian S.; Graham, Todd

    1992-11-01

    This paper summarizes work by Rockwell International's Space Systems Division's Robotics Group at Downey, California. The work is part of a NASA-led team effort to automate Space Shuttle rewaterproofing in the Orbiter Processing Facility at the Kennedy Space Center and the ferry facility at the Ames-Dryden Flight Research Facility. Rockwell's effort focuses on the rewaterproofing end-effector, whose function is to inject hazardous dimethylethyloxysilane into thousands of ceramic tiles on the underside of the orbiter after each flight. The paper has five sections. First, it presents background on the present manual process. Second, end-effector requirements are presented, including safety and interface control. Third, a design is presented for the five end-effector systems: positioning, delivery, containment, data management, and command and control. Fourth, end-effector testing and integrating to the total system are described. Lastly, future applications for this technology are discussed.

  12. End-of-Life Conversation Game Increases Confidence for Having End-of-Life Conversations for Chaplains-in-Training.

    Science.gov (United States)

    Van Scoy, Lauren Jodi; Watson-Martin, Elizabeth; Bohr, Tiffany A; Levi, Benjamin H; Green, Michael J

    2018-04-01

    Discussing end-of-life issues with patients is an essential role for chaplains. Few tools are available to help chaplains-in-training develop end-of-life communication skills. This study aimed to determine whether playing an end-of-life conversation game increases the confidence for chaplain-in-trainings to discuss end-of-life issues with patients. We used a convergent mixed methods design. Chaplains-in-training played the end-of-life conversation game twice over 2 weeks. For each game, pre- and postgame questionnaires measured confidence discussing end-of-life issues with patients and emotional affect. Between games, chaplains-in-training discussed end-of-life issues with an inpatient. One week after game 2, chaplains-in-training were individually interviewed. Quantitative data were analyzed using descriptive statistics and Wilcoxon rank-sum t tests. Content analysis identified interview themes. Quantitative and qualitative data sets were then integrated using a joint display. Twenty-three chaplains-in-training (52% female; 87% Caucasian; 70% were in year 1 of training) completed the study. Confidence scores (scale: 15-75; 75 = very confident) increased significantly after each game, increasing by 10.0 points from pregame 1 to postgame 2 ( P game, and shyness subscale scores decreased significantly after each game. Content analysis found that chaplains-in-training found the game to be a positive, useful experience and reported that playing twice was beneficial (not redundant). Mixed methods analysis suggest that an end-of-life conversation game is a useful tool that can increase chaplain-in-trainings' confidence for initiating end-of-life discussions with patients. A larger sample size is needed to confirm these findings.

  13. Eficácia da eletroestimulação muscular expiratória na tosse de pacientes após acidente vascular encefálico Effectiveness of electrical stimulation in expiratory muscle on cough of patients after stroke

    Directory of Open Access Journals (Sweden)

    André Luís Ferreira de Meireles

    2012-12-01

    recruitment in many muscle groups and pathologies. The present study aimed to evaluate the efficiency of electrical stimulation with median frequencies (ETMF in expiratory muscles strength and cough in patients with sequels of stroke. It is a quasi-experimental study (before and after where 11 individuals were selected after stroke between 40 and 65 years, both sexes and hemodynamically stable. Patients were evaluated about clinic and respiratory scores (ventilometer, peak of expiratory flow (PEF and manometer (MIP and MEP and submitted to the protocol, which consisted of ETMF in expiratory muscle (abdominals rectus with the unit of Russian current with 2,500 Hz carrier frequency modulated at 40 Hz for 15 minutes by 15 sessions. In the initial assessment evidenced decreasing in inspiratory and expiratory muscular strength (MIP, MEP and PEF when compared to predicted values in literature. In the end of ETMF it happened an increase in MIP, MEP without statistical significance (p=0.18 and p=0.29 but the PEF has had an increase of 283.73 L/minute to 347.27 L/minute (p=0.03. It can be seen that the ETMF was effective in the improvement of the parameters evaluated, with PEF being the greatest impact and statistical significance, however further studies with larger populations are necessary to analyze this new therapeutic approach.

  14. Salt Lake Cityst Torinoni / Olev Remsu

    Index Scriptorium Estoniae

    Remsu, Olev, 1947-

    2006-01-01

    Dokumentaalfilm Eesti suusameeskonna valmistumisest Torino olümpiamängudeks "Tiim" : idee autorid Peep Puks, Hans Roosipuu : režissöör Peep Puks : F-Seitse 2006. Esilinastus toimus 26. mail Otepääl, ETVs 31. mail

  15. Photon beam position monitor

    Science.gov (United States)

    Kuzay, Tuncer M.; Shu, Deming

    1995-01-01

    A photon beam position monitor for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade "shadowing". Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation.

  16. The effect of habitual waterpipe tobacco smoking on pulmonary function and exercise capacity in young healthy males: A pilot study.

    Science.gov (United States)

    Hawari, F I; Obeidat, N A; Ghonimat, I M; Ayub, H S; Dawahreh, S S

    2017-01-01

    Evidence regarding the health effects of habitual waterpipe smoking is limited, particularly in young smokers. Respiratory health and cardiopulmonary exercise tests were compared in young male habitual waterpipe smokers (WPS) versus non-smokers. 69 WPS (≥3 times/week for three years) and 69 non-smokers were studied. Respiratory health was assessed through the American Thoracic Society and the Division of Lung Diseases (ATS-DLD-78) adult questionnaire. Pulmonary function and cardiopulmonary exercise tests were performed. Self-reported respiratory symptoms, forced expiratory volume in first second (FEV 1 ), forced vital capacity (FVC), FEV 1 /FVC ratio, forced expiratory flow between 25 and 75% of FVC (FEF 25-75% ), peak expiratory flow (PEF), exercise time, peak end-tidal CO 2 tension (PetCO 2 ), subject-reported leg fatigue and dyspnea; peak O 2 uptake (VO 2 max), and end-expiratory lung volume (EELV) change from baseline (at peak exercise) were measured. WPS were more likely than non-smokers to report respiratory symptoms. WPS also demonstrated: shorter exercise time; lower peak VO 2 ; higher perceived dyspnea at mid-exercise; lower values of the following: FEV 1 , FVC, PEF, and EELV change. Habitual waterpipe tobacco smoking in young seemingly healthy individuals is associated with a greater burden of respiratory symptoms and impaired exercise capacity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. [Acute care of critically ill children in general hospitals: organisation and training].

    Science.gov (United States)

    van Sambeeck, S J L; Janssen, E J M; Hundscheid, T; Martens, S J L; Vos, G D

    2013-01-01

    To gain insight into how the acute care of critically ill children at general hospitals is organised, whether staff is sufficiently trained and whether the necessary materials and medications are present. Questionnaire combined with a site visit. Questionnaires were sent to all primarily involved specialists (emergency room specialists and paediatricians), and to the auxiliary anaesthetists and intensivists involved, at the nine general hospitals in Southeast Netherlands. Two researchers performed standardised interviews with the lead paediatricians on site and checked for materials and medication present in the emergency and paediatric departments. Of the 195 questionnaires sent, 97 (49.7%) were deemed suitable for analysis. The response from the primary specialists involved (77.6%) was more than twice that of the auxiliary specialists (31.9%). At 7 hospitals, verbal agreements on the organisation of acute care were maintained, 1 hospital had a written protocol, and 2 hospitals had a task force addressing this topic. One out of 5 respondents was unaware of the verbal agreements and 1 out of 3 mistakenly assumed that a protocol existed. Two out of 3 primary specialists involved were certified for Advanced Paediatric Life Support (APLS); 1 out of 13 of the auxiliary specialists had such a certificate. Scenario training was being conducted at 8 hospitals. A paediatric resuscitation cart was available at both the emergency and paediatric departments of 8 hospitals, 3 of which were fully stocked at both departments. Laryngeal mask airways and PEEP-valves (Positive End Expiratory Pressure) were lacking at 6 of the 9 hospitals. The medication stock was complete at all the hospitals. The organisation of and training for the acute care of critically ill children and presence of materials - the aspects we investigated - need attention at all general hospitals evaluated. It appeared that many specialists are not APLS certified and written protocols concerning organisation

  18. Hemorragia alveolar maciça como manifestação inicial de poliangeíte microscópica Diffuse alveolar hemorrhage as initial manifestation of microscopic polyangiitis

    Directory of Open Access Journals (Sweden)

    Cristiano Barbosa Campanholo

    2007-02-01

    Full Text Available Hemorragia alveolar (HA é uma manifestação clínica com alta taxa de mortalidade que deve ser investigada, reconhecida e estabilizada. Causas possíveis para a HA incluem infecções respiratórias ou sistêmicas, malformações arteriovenosas, estenose mitral, discrasias sangüíneas e doenças auto-imunes, como o lúpus eritematoso sistêmico (LES, a síndrome de Goodpasture e as vasculites sistêmicas primárias, principalmente aquelas associadas aos anticorpos anticitoplasma de neutrófilos (Anca, como a granulomatose de Wegener, síndrome de Churg-Strauss e a poliangeíte microscópica. Relatamos o caso de uma paciente jovem que apresentou quadro grave de HA necessitando ventilação mecânica assistida com pressão expiratória final positiva (Peep. Na ausência de evidências de infecção, discrasias sangüíneas ou malformações arteriovenosas, a paciente foi submetida à corticoterapia e à imunossupressão, com controle satisfatório da atividade da doença, que persiste após 24 meses de seguimento. Os dados clínicos, laboratoriais e histopatológicos permitiram estabelecer o diagnóstico de poliangeíte microscópica.Alveolar hemorrhage (AH is a clinical manifestation with high mortality rate that must be promptly investigated, recognized and stabilized. Causes of AH include systemic and respiratory tract infections, arterio-venous malformations, blood dyscrasias and autoimmune diseases such as systemic lupus erithematosus, Goodpasture syndrome and primary systemic vasculitis, specially the antineutrophil cytoplasmic antibodies-associated vasculitis such as Wegener’s granulomatosis, Churg-Strauss syndrome and microscopic polyangiitis. We report the case of a young female patient who developed severe AH necessitating orotracheal intubation and mechanic assisted ventilation with positive end expiratory pressure. Since no evidence of infection, malformation or blood dyscrasia was found, immediate therapy with glucocorticoids and

  19. Front end support systems for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Barraza, J.; Shu, D.; Kuzay, T.M.

    1993-01-01

    The support system designs for the Advanced Photon Source (APS) front ends are complete and will be installed in 1994. These designs satisfy the positioning and alignment requirements of the front end components installed inside the storage ring tunnel, including the photon beam position monitors, fixed masks, photon and safety shutters, filters, windows, and differential pumps. Other components include beam transport pipes and ion pumps. The designs comprise 3-point kinematic mounts and single axis supports to satisfy various multi-direction positioning requirements from course to ultra-precise. The confined space inside the storage ring tunnel has posed engineering challenges in the design of these devices, considering some components weigh as much as 500 kg. These challenges include designing for mobility during commissioning and initial alignment, mechanical and thermal stability, and precise low profile vertical and horizontal positioning. As a result, novel stages and kinematic mounts have emerged with modular and standard designs. This paper will discuss the diverse group of support systems, including specifications and performance data of the prototypes

  20. Both movement-end and task-end are critical for error feedback in visuomotor adaptation: a behavioral experiment.

    Directory of Open Access Journals (Sweden)

    Takumi Ishikawa

    Full Text Available An important issue in motor learning/adaptation research is how the brain accepts the error information necessary for maintaining and improving task performance in a changing environment. The present study focuses on the effect of timing of error feedback. Previous research has demonstrated that adaptation to displacement of the visual field by prisms in a manual reaching task is significantly slowed by delayed visual feedback of the endpoint, suggesting that error feedback is most effective when given at the end of a movement. To further elucidate the brain mechanism by which error information is accepted in visuomotor adaptation, we tested whether error acceptance is linked to the end of a given task or to the end of an executed movement. We conducted a behavioral experiment using a virtual shooting task in which subjects controlled their wrist movements to meet a target with a cursor as accurately as possible. We manipulated the timing of visual feedback of the impact position so that it occurred either ahead of or behind the true time of impact. In another condition, the impact timing was explicitly indicated by an additional cue. The magnitude of the aftereffect significantly varied depending on the timing of feedback (p < 0.05, Friedman's Test. Interestingly, two distinct peaks of aftereffect were observed around movement-end and around task-end, irrespective of the existence of the timing cue. However, the peak around task-end was sharper when the timing cue was given. Our results demonstrate that the brain efficiently accepts error information at both movement-end and task-end, suggesting that two different learning mechanisms may underlie visuomotor transformation.