WorldWideScience

Sample records for pedicle surgical technique

  1. Postero-Inferior Pedicle Surgical Technique for the Treatment of Grade III Gynecomastia.

    Science.gov (United States)

    Thiénot, Sophie; Bertheuil, Nicolas; Carloni, Raphaël; Méal, Cécile; Aillet, Sylvie; Herlin, Christian; Watier, Eric

    2017-06-01

    Surgical treatment of Grade III gynecomastia generally utilizes mastectomy techniques and free transplantation of the nipple-areola complex. Moreover, with rising obesity rates and the development of bariatric surgery, an increasing demand for correctional surgery for pseudogynecomastia has been observed, which is comparable to Grade III gynecomastia in terms of its surgical management. Here, we describe an innovative technique to deal with these new demands: fascio-cutaneous flap by postero-inferior pedicle. All patients in the Department of Plastic Surgery from our University Hospital suffering from Grade III gynecomastia or pseudogynecomastia underwent surgery via the postero-inferior pedicle flap technique. Briefly, we performed extensive liposuction of the infero-internal and infero-external mammary quadrants followed by liposuction of the deep tissues of the superior quadrants, except in the area of the pedicle. After removing the skin just above the dermis of the inferior quadrants and performing de-epithelialization of the postero-inferior pedicle flap, the thoracic flap was lowered and the areola transposed. Nine patients underwent surgery between March 2015 and March 2016, and their results were collected prospectively. The mean patient age was 46.6 years, the mean weight was 94.2 kg, and the mean body mass index was 30.8 kg/m 2 . In addition, the mean operative time was 132 min, the mean liposuction volume was 633 mL, the excised weight was 586 g, and the mean hospitalization and drainage durations were 3.8 days. No major complications occurred, no re-intervention was required, and no recurrence was found. We report a new operative technique using a postero-inferior pedicle. Its main advantage is preservation of neurovascular function, which makes this a promising technique for patients who wish to maintain nipple sensitivity. This surgery is reliable and reproducible. We recommend it as the first line treatment for Grade III gynecomastia because

  2. Surgical treatment of gynecomastia with severe ptosis: periareolar incision and dermal double areolar pedicle technique.

    Science.gov (United States)

    Cannistra, Claudio; Piedimonte, Andrea; Albonico, Fiorella

    2009-11-01

    Gynecomastia is a morphostructural impairment of the mammary region in men caused by parenchymal hypertrophy or a cutaneous distortion of breast skin covering or both. The clinical classification introduced by Simon et al. in 1973 ranks gynecomastia in three degrees. Each subtype can be treated with a specific technique. This article describes an alternative surgical procedure for treating gynecomastia with severe ptosis(type III and type IIIb of Simon's classification). Fifty-eight patients were treated for gynecomastia in our Plastic Surgery Unit from 1996 to 2004. The cutaneous excess of periareolar skin is evaluated by a pinching test. A circular periareolar mark is traced corresponding to the cutaneous excess that has to be removed.Initially, liposuction of adipous tissue on the periphery of the mammary region is performed through two cutaneous 3-mm incisions at the 3 o'clock and 9 o'clock positions around the areola. After this, the liposuction incisions are enlarged from 10 o'clock to 8 o'clock and from 2 o'clockto 4 o'clock to create access for the mastectomy. This dissection creates a double dermal areolar pedicle. The new areolar position is fixed with a Benelli round block suture. A resolution of the morphologic deformity without evident scars after hair growth and a correction of the breast deformity has been observed in the 6-month follow-ups conducted for all the patients. We observed that the vascular-nervous net under the areola at 12 o'clock and 6 o'clock is very important, more so than the lateral pedicle, and the conservation of a double vascular-nervous pedicle reduces significantly the risk of areolar necrosis, especially in cases of gynecomastia type III and in cases where there is a high degree of breast malformation such as the tuberous breast.

  3. "Two-step" technique with OsiriXTM to evaluate feasibility of C2 pedicle for surgical fixation

    Directory of Open Access Journals (Sweden)

    Luis Miguel Sousa Marques

    2016-01-01

    Full Text Available Background: Surgical treatment of craniovertebral junction pathology has evolved considerably in recent decades with the implementation of short atlanto-axial fixation techniques, notwhithstanding increasing neurovascular risks. Also, there is strong evidence that fixation of C2 anatomical pedicle has the best biomechanical profile of the entire cervical spine. However, it is often difficult and misleading, to evaluate anatomical bony and vascular anomalies using the three orthogonal planes (axial, coronal, and sagittal of CT. Objectives: The authors describe an innovative and simple technique to evaluate the feasibility of C2 pedicle for surgical screw fixation using preoperative planning with the free DICOM (Digital Imaging and Communications in Medicine software OsiriX TM . Materials and Methods: The authors report the applicatin of this novel technique in 5 cases (3 traumatic, 1 Os Odontoideum, and 1 complex congenital malformation collected from our general case series of the Department in the last 5 years. Results: In this "proof of concept" study, the pre-operative analysis with the "two-step" tecnique was detrimental for choosing the surgical tecnique. Detailed post-operative analysis confirmed correct position of C2 screws without cortical breach. There were no complications or mortality reported. Conclusion: This "two-step" technique is an easy and reliable way to determine the feasibility of C2 pedicle for surgical fixation. The detailed tridimensional radiological preoperative evaluation of craniovertebral junction anatomy is critical to the sucess and safety of this surgeries, and can avoid, to certain degree, expensive intra-operative tridimensional imaging facilities.

  4. Effectiveness of the Thoracic Pedicle Screw Placement Using the Virtual Surgical Training System: A Cadaver Study.

    Science.gov (United States)

    Hou, Yang; Lin, Yanping; Shi, Jiangang; Chen, Huajiang; Yuan, Wen

    2018-03-14

    The virtual simulation surgery has initially exhibited its promising potentials in neurosurgery training. To evaluate effectiveness of the Virtual Surgical Training System (VSTS) on novice residents placing thoracic pedicle screws in a cadaver study. A total of 10 inexperienced residents participated in this study and were randomly assigned to 2 groups. The group using VSTS to learn thoracic pedicle screw fixation was the simulation training (ST) group and the group receiving an introductory teaching session was the control group. Ten fresh adult spine specimens including 6 males and 4 females with a mean age of 58.5 yr (range: 33-72) were collected and randomly allocated to the 2 groups. After exposing anatomic structures of thoracic spine, the bilateral pedicle screw placement of T6-T12 was performed on each cadaver specimen. The postoperative computed tomography scan was performed on each spine specimen, and experienced observers independently reviewed the placement of the pedicle screws to assess the incidence of pedicle breach. The screw penetration rates of the ST group (7.14%) was significantly lower in comparison to the control group (30%, P < .05). Statistically significant difference in acceptable rates of screws also occurred between the ST (100%) and control (92.86%) group (P < .05). In addition, the average screw penetration distance in control group (2.37 mm ± 0.23 mm) was significantly greater than ST group (1.23 mm ± 0.56 mm, P < .05). The virtual reality surgical training of thoracic pedicle screw instrumentation effectively improves surgical performance of novice residents compared to those with traditional teaching method, and can help new beginners to master the surgical technique within shortest period of time.

  5. Evaluation of an omental pedicle extension technique in the dog.

    Science.gov (United States)

    Ross, W E; Pardo, A D

    1993-01-01

    A two-step omental pedicle extension technique was performed on 10 dogs. Step 1 of the pedicle extension involved release of the dorsal leaf of the omentum from its pancreatic attachment, whereas step 2 consisted of an inverse L-shaped incision to double the length of the pedicle. The pedicle dimensions were measured and the distance reached when extended toward the hind limb, forelimb, and the muzzle recorded after each stage of the procedure. The vascular patency of the pedicle was determined by intravenous injection of fluorescein dye after the second stage of omental extension. Mean pedicle lengths were 44.5 cm with the first stage of extension and 82.0 cm after full extension. The mean width at the caudal extent of the pedicles after dorsal and full extension was 30.4 cm and 17.2 cm, respectively. Eight of the 10 pedicles were patent after full extension. The fully extended omental pedicles reached and, in most cases, extended beyond the distal extremities and the muzzle. The findings in this study suggest that the canine omentum can be extended to any part of the body without being detached from its vascular supply.

  6. Current trends in pedicle screw stimulation techniques: lumbosacral, thoracic, and cervical levels.

    Science.gov (United States)

    Isley, Michael R; Zhang, Xiao-Feng; Balzer, Jeffrey R; Leppanen, Ronald E

    2012-06-01

    Unequivocally, pedicle screw instrumentation has evolved as a primary construct for the treatment of both common and complex spinal disorders. However an inevitable and potentially major complication associated with this type of surgery is misplacement of a pedicle screw(s) which may result in neural and vascular complications, as well as impair the biomechanical stability of the spinal instrumentation resulting in loss of fixation. In light of these potential surgical complications, critical reviews of outcome data for treatment of chronic, low-back pain using pedicle screw instrumentation concluded that "pedicle screw fixation improves radiographically demonstrated fusion rates;" however the expense and complication rates for such constructs are considerable in light of the clinical benefit (Resnick et al. 2005a). Currently, neuromonitoring using free-run and evoked (triggered) electromyography (EMG) is widely used and advocated for safer and more accurate placement of pedicle screws during open instrumentation procedures, and more recently, guiding percutaneous placement (minimally invasive) where the pedicle cannot be easily inspected visually. The latter technique, evoked or triggered EMG when applied to pedicle screw instrumentation surgeries, has been referred to as the pedicle screw stimulation technique. As concluded in the Position Statement by the American Society of Neurophysiological Monitoring (ASNM), multimodality neuromonitoring using free-run EMG and the pedicle screw stimulation technique was considered a practice option and not yet a standard of care (Leppanen 2005). Subsequently, the American Association of Neurological Surgeons/Congress of Neurological Surgeons (AANS/CNS) Joint Section on Disorders of the Spine and Peripheral Nerves published their "Guidelines for the Performance of Fusion Procedures for Degenerative Disease of the Lumbar Spine" (Heary 2005, Resnick et al. 2005a, Resnick et al. 2005b). It was concluded that the "primary

  7. Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.

    Science.gov (United States)

    Kil, Jin-Sang; Park, Jong-Tae

    2018-05-01

    Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.

  8. Alternative radiation-free registration technique for image-guided pedicle screw placement in deformed cervico-thoracic segments.

    Science.gov (United States)

    Kantelhardt, Sven R; Neulen, Axel; Keric, Naureen; Gutenberg, Angelika; Conrad, Jens; Giese, Alf

    2017-10-01

    Image-guided pedicle screw placement in the cervico-thoracic region is a commonly applied technique. In some patients with deformed cervico-thoracic segments, conventional or 3D fluoroscopy based registration of image-guidance might be difficult or impossible because of the anatomic/pathological conditions. Landmark based registration has been used as an alternative, mostly using separate registration of each vertebra. We here investigated a routine for landmark based registration of rigid spinal segments as single objects, using cranial image-guidance software. Landmark based registration of image-guidance was performed using cranial navigation software. After surgical exposure of the spinous processes, lamina and facet joints and fixation of a reference marker array, up to 26 predefined landmarks were acquired using a pointer. All pedicle screws were implanted using image guidance alone. Following image-guided screw placement all patients underwent postoperative CT scanning. Screw positions as well as intraoperative and clinical parameters were retrospectively analyzed. Thirteen patients received 73 pedicle screws at levels C6 to Th8. Registration of spinal segments, using the cranial image-guidance succeeded in all cases. Pedicle perforations were observed in 11.0%, severe perforations of >2 mm occurred in 5.4%. One patient developed a transient C8 syndrome and had to be revised for deviation of the C7 pedicle screw. No other pedicle screw-related complications were observed. In selected patients suffering from pathologies of the cervico-thoracic region, which impair intraoperative fluoroscopy or 3D C-arm imaging, landmark based registration of image-guidance using cranial software is a feasible, radiation-saving and a safe alternative.

  9. Surgical outcome of posterior lumbar interbody fusion with pedicle screw fixation for lumbar spondylolisthesis

    International Nuclear Information System (INIS)

    Shoda, Motoi; Kuno, Shigehiko; Inoue, Tatsushi

    2009-01-01

    Problems of lumbar spondylolisthesis treatment are many surgical tactics, elderly patient, osteoporosis, complications and recurrence of the symptoms. PLIF (posterior lumbar interbody fusion) and PS (pedicle screw) fixation technique for lumbar spondylolisthesis provide good patient satisfaction. Good outcome has been reported by only laminectomy alone, but patient satisfaction becomes worse year after year. The role of instrumentation for lumbar spondylolisthesis is decompression of the nerve root, correction of lumbar pathologies, bony fusion and early mobilization. We show our surgical technique and long term outcome of PLIF with PS for lumbar spondylolisthesis. Three hundred and fifty cases of lumbar spondylolisthesis were operated on in Department of Neurosurgery, Fujita Health University during the period of from December 1992 to August 2008. Patient background: age 16-84 years old (mean 62.5), Gender: male 153, female 197. Follow-up period 1-180 months (mean 61.2). Degenerative: 255, Isthmic: 63, Dysplastic: 10, Fracture: 5 and scoliosis 16 cases. Surgical procedure was PS with interbody fusion cage: 331, Hybrid cage (titanium cage with hydroxyapatite) 314, PS with Cerabone: 2 and PS with autograft: 17. CT was done to evaluate bony fusion postoperatively. Post operative improvements by JOA (Japan Orthopedic Association) score is 11.4 before surgery, 24.1 (post op. within 2 years), 25.4 (post op. 2-5 years), 25.0 (post op. 5-10 years) and 22.4 (post op. 10-15 years). Significant improvements were observed in %Slip and Slip angle but no remarkable change was observed in lumbar lordotic angle by postoperative X-ray evaluation. No root injury, and systemic complication except 4 cases of cerebrospinal fluid (CSF) leakage during surgery. Two cases were reoperated in whom cage with autograft migration due to pseudoarthrosis. Two cases had to undergo screw and cage system removal due to infection. Two cases of adjacent level stenosis had to undergo operation 10

  10. Mandible vertical height correction using lingual bone-split pedicle onlay graft technique

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2006-09-01

    Full Text Available As edentulous mandible become atrophic, a denture bearing area will also be reduced. Difficulty in the removable prosthesis rehabilitation will be present as well. The purpose of this paper reports an innovative surgical technique to cope a problem of unstable complete lower denture due to bone atrophy and resulted of vertical height reduction of the anterior region of the mandible necessary for denture retention. Vertical advancement of the lower jaw using lingual bone split pedicle onlay graft technique in the anterior region of the mandible and followed by secondary epithelization vestibuloplasty in achieving the vertical height dimension. The surgery was achieved satisfactorily as the vertical dimension of the mandible anterior region had increased and the denture seated more stable comparing with the previous denture worn by the patient. It concluded that the surgery was achieved with a great result as the vertical height of the anterior region of the mandible had increased positively therefore lead the denture seated more stable.

  11. Utility of Glissonean Pedicle Transection for Surgical Treatment of Severe Liver Trauma

    Directory of Open Access Journals (Sweden)

    Satoshi Koizumi

    2017-04-01

    Full Text Available The most common initial strategy for treatment of severe liver trauma is damage control in which hemostasis is achieved by perihepatic gauze packing and/or vascular embolization. However, we encounter patients in whom this strategy alone is not adequate. We have applied the principles of Glissonean pedicle transection, a technique that was originally devised to ensure safe and quick performance of planned hepatectomy for liver cancer, to 3 cases of severe liver trauma. We performed Glissonean pedicle ligation during damage control surgery in 2 patients and Glissonean pedicle transection during the definitive surgery in 1 patient. We describe the approaches and our experience with them, including operation times and outcomes. From our experience thus far, it seems that 8–12 h after the damage control procedure is appropriate for performing the definitive surgery. Although there are some problems posed by this strategy and cases to which it will not be applicable, the method seems to be particularly useful for cases of severe liver trauma in which the damage is extensive and involves the Glissonean pedicles near the hepatic hilus. We describe our 3 cases in detail and review our experience in light of the available literature.

  12. Feasibility study of patient-specific surgical templates for the fixation of pedicle screws.

    Science.gov (United States)

    Salako, F; Aubin, C-E; Fortin, C; Labelle, H

    2002-01-01

    Surgery for scoliosis, as well as other posterior spinal surgeries, frequently uses pedicle screws to fix an instrumentation on the spine. Misplacement of a screw can lead to intra- and post-operative complications. The objective of this study is to design patient-specific surgical templates to guide the drilling operation. From the CT-scan of a vertebra, the optimal drilling direction and limit angles are computed from an inverse projection of the pedicle limits. The first template design uses a surface-to-surface registration method and was constructed in a CAD system by subtracting the vertebra from a rectangular prism and a cylinder with the optimal orientation. This template and the vertebra were built using rapid prototyping. The second design uses a point-to-surface registration method and has 6 adjustable screws to adjust the orientation and length of the drilling support device. A mechanism was designed to hold it in place on the spinal process. A virtual prototype was build with CATIA software. During the operation, the surgeon places either template on patient's vertebra until a perfect match is obtained before drilling. The second design seems better than the first one because it can be reused on different vertebra and is less sensible to registration errors. The next step is to build the second design and make experimental and simulations tests to evaluate the benefits of this template during a scoliosis operation.

  13. Asymmetric C7 pedicle subtraction osteotomy for correction of rigid cervical coronal imbalance secondary to post-traumatic heterotopic ossification: a case report, description of a novel surgical technique, and literature review.

    Science.gov (United States)

    Theologis, Alexander A; Bellevue, Kate D; Qamirani, Erion; Ames, Christopher P; Deviren, Vedat

    2017-05-01

    Deformities of the cervical spine are uncommon in the coronal plane. In this report, a unique case of a 31-year-old male with a fixed, 30° left coronal deformity due to heterotopic ossification 3 years status post poly-trauma was treated with an asymmetric C7 pedicle subtraction osteotomy (PSO). Case report. Pre-operatively, the patient had a fixed 45-degree left tilt of his neck and radiographs demonstrated a rigid 30° scoliosis, 7 cm coronal imbalance, and 4 cm negative sagittal balance, diffuse bridging bone between the spinous processes and the facet joints of C5 to T1 bilaterally. An asymmetric C7 PSO with C2-T3 posterior spinal fusion was completed without complication. There was residual 9° coronal deformity, 2.9 cm left coronal imbalance, and 2.3 cm sagittal imbalance. He had a marked improvement in his function, as assessed by the SF-36 physical component score (pre-op 31.1; post-op 44.7) and mental component score (pre-op 46.0; post-op 66.8). Post-operatively, neck disability index scores also improved (pre-op 38; post-op 16). Although the patient passed away from a drug overdose 14 months post-operatively, he did not report neck pain, he had not sought evaluation from another physician for his neck, and he had not undergone a subsequent neck operation before his passing. In this one patient, an asymmetric C7 PSO was performed safely. While it was effective in addressing a fixed cervical coronal imbalance, its efficacy and safety profile should be confirmed in larger cohorts.

  14. A Simple Suturing Technique for Laparoscopic Ligation of Vascular Pedicles

    Directory of Open Access Journals (Sweden)

    Keith A. Aqua

    1996-01-01

    Full Text Available We report on the performance of 348 adnexectomies and 35 uterine artery ligations for both benign and malignant disease using a simple laparoscopic suturing technique. Only 5-mm ports are required, and there was no morbidity directly associated with this approach. The procedure can be performed quickly, is relatively inexpensive, and allows hysterectomy and oophorectomy to be performed without bipolar electrocautery.

  15. Pedicle Screw Insertion Accuracy Using O-Arm, Robotic Guidance, or Freehand Technique: A Comparative Study.

    Science.gov (United States)

    Laudato, Pietro Aniello; Pierzchala, Katarzyna; Schizas, Constantin

    2018-03-15

    A retrospective radiological study. The aim of this study was to evaluate the accuracy of pedicle screw insertion using O-Arm navigation, robotic assistance, or a freehand fluoroscopic technique. Pedicle screw insertion using either "O-Arm" navigation or robotic devices is gaining popularity. Although several studies are available evaluating each of those techniques separately, no direct comparison has been attempted. Eighty-four patients undergoing implantation of 569 lumbar and thoracic screws were divided into three groups. Eleven patients (64 screws) had screws inserted using robotic assistance, 25 patients (191 screws) using the O-arm, while 48 patients (314 screws) had screws inserted using lateral fluoroscopy in a freehand technique. A single experienced spine surgeon assisted by a spinal fellow performed all procedures. Screw placement accuracy was assessed by two independent observers on postoperative computed tomography (CTs) according to the A to D Rampersaud criteria. No statistically significant difference was noted between the three groups. About 70.4% of screws in the freehand group, 69.6% in the O arm group, and 78.8% in the robotic group were placed completely within the pedicle margins (grade A) (P > 0.05). About 6.4% of screws were considered misplaced (grades C&D) in the freehand group, 4.2% in the O-arm group, and 4.7% in the robotic group (P > 0.05). The spinal fellow inserted screws with the same accuracy as the senior surgeon (P > 0.05). The advent of new technologies does not appear to alter accuracy of screw placement in our setting. Under supervision, spinal fellows might perform equally well to experienced surgeons using new tools. The lack of difference in accuracy does not imply that the above-mentioned techniques have no added advantages. Other issues, such as surgeon/patient radiation, fiddle factor, teaching suitability, etc., outside the scope of our present study, need further assessment. 3.

  16. Metal Artifacts Reduction of Pedicle Screws on Spine Computed Tomography Images Using Variable Thresholding Technique

    International Nuclear Information System (INIS)

    Kaewlek, T.; Koolpiruck, D.; Thongvigitmanee, S.; Mongkolsuk, M.; Chiewvit, P.; Thammakittiphan, S.

    2012-01-01

    Metal artifacts are one of significant problems in computed tomography (CT). The streak lines and air gaps arise from metal implants of orthopedic patients, such as prosthesis, dental bucket, and pedicle screws that cause incorrect diagnosis and local treatment planning. A common technique to suppressed artifacts is by adjusting windows, but those artifacts still remain on the images. To improve the detail of spine CT images, the variable thresholding technique is proposed in this paper. Three medical cases of spine CT images categorized by the severity of artifacts (screws head, one full screw, and two full screws) were investigated. Metal regions were segmented by k-mean clustering, then transformed into a sinogram domain. The metal sinogram was identified by the variable thresholding method, and then replaced the new estimated values by linear interpolation. The modified sinogram was reconstructed by the filtered back- projection algorithm, and added the metal region back to the modified reconstructed image in order to reproduce the final image. The image quality of the proposed technique, the automatic thresholding (Kalender) technique, and window adjustment technique was compared in term of noise and signal to noise ratio (SNR). The propose method can reduce metal artifacts between pedicle screws. After processing by our proposed technique, noise in the modified images is reduced (screws head 121.15 to73.83, one full screw 160.88 to 94.04, and two full screws 199.73 to 110.05 from the initial image) and SNR is increased (screws head 0.87 to 1.88, one full screw 1.54 to 2.82, and two full screws 0.32 to 0.41 from the initial image). The variable thresholding technique can identify the suitable boundary for restoring the missing data. The efficiency of the metal artifacts reduction is indicated on the case of partial and full pedicle screws. Our technique can improve the detail of spine CT images better than automatic thresholding (Kalender) technique, and

  17. Surgical outcome of posterior decompression, posterolateral fusion and stabilization by pedicle screw and rod in thoracolumbar tuberculosis

    Directory of Open Access Journals (Sweden)

    Md. Anowarul Islam

    2017-05-01

    Full Text Available Spinal tuberculosis causes severe complications like neurological and spinal deformity which may lead to respiratory distress, costo-pelvic impingement, paraplegia and consequent reduction in the quality and longevity of life. The aim of the present treatment is to avoid the consequence of neural complications and gain near-normal spine. Mechanical factor causes pathological fracture or dislocation of an affected vertebral body. Surgical decompression ensues further instability. Reconstruction of spinal column by pedicle screw and rod provide stability and prevents secondary neural damage and deformity thereby helps in early mobilization. Prospective study was done to evaluate the results in 20 cases of spinal tuberculosis in thoracolumbar region associated with neurological deficit. We operated our cases (12 males and 8 females by posterolateral decompression, fusion and stabilization by pedicle screw and rod along with antitubercular drug treatment. All patients were with neurological deficit, single level involvement and 10 to 30 degree of mild kyphosis. After surgery, kyphosis improved from 20.7 ± 5.5 degrees to 12.5 ± 3.9 degree. Bony fusion was in 65.0% cases. Neurological improvement and pain subsided in all the patients.

  18. Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures compared with open technique.

    Science.gov (United States)

    Paredes, Igor; Panero, Irene; Cepeda, Santiago; Castaño-Leon, Ana M; Jimenez-Roldan, Luis; Perez-Nuñez, Ángel; Alén, Jose A; Lagares, Alfonso

    2018-06-14

    This study aimed to compare the accuracy of screw placement between open pedicle screw fixation and percutaneous pedicle screw fixation (MIS) for the treatment of thoracolumbar spine fractures (TSF). Forty-nine patients with acute TSF who were treated with transpedicular screw fixation from January 2013 to December 2016 were retrospectively reviewed. The patients were divided into Open and MIS groups. Laminectomy was performed in either group if needed. The accuracy of the screw placement, the evolution of the Cobb sagital angle postoperatively and at 12-month follow up and the neurological status were recorded. AO type of fracture and TLICS score were also recorded. Mean age was 42 years old. Mean TLICS score was 6,29 and 5,96 for open and MIS groups respectively. Twenty five MIS and 24 open surgeries were performed, and 350 (175 in each group) screws were inserted (7,14 per patient). Twenty-four and 13 screws were considered ̈out ̈ in the open and MIS groups respectively (Odds ratio 1,98. 0,97-4,03 p=0,056). The Cobb sagittal angle went from 13,3o to 4,5o and from 14,9o to 8,2o in the Open and MIS groups respectively (both popen and MIS groups respectively. No neurological worsening was observed. For the treatment of acute thoracolumbar fractures, the MIS technique seems to achieve similar results to the open technique in relation to neurological improvement and deformity correction, while placing the screws more accurately.

  19. The transverse penile pedicled flap urethroplasty: description of a simplified technique for the dissection of the Fascio-cutaneous flap.

    Science.gov (United States)

    Shittu, O B; Sotunmbi, P T

    2015-06-01

    Urethroplasty is often required for long urethral strictures or urethral strictures that have recurred after repeated urethral dilatations or urethrotomy. The transvers penile skin pedicled flap is very versatile for the reconstruction of long urethral stricture. However the meticulous sharp dissection required to develop it takes a long time to do and may be associated with button hole injuries to the vascular pedicle and the penile skin. We describe a simplified technique of raising the flap which does not require sharp dissection and is very quick to accomplish. Technique involves using a circumcising distal penile shaft skin incision to de-glove the penis by blunt dissection. The skin substitute, adequate to give appropriate urethra calibre is similarly dissected bluntly along with its vascular pedicle from the proximal penile skin. The techniques used to facilitate successful blunt dissection are described. In 9 adults with long, multiple urethral strictures, the average time to develop the flap was 15 minutes and complication have been limited to temporary urethro-cutaneous fistula at the ventral part of the circular skin closure. These fistulae closed on conservative treatment. No patient suffered button-hole injuries to either the vascular pedicle or the penile skin. This modification to the standard sharp dissection is very quick to accomplish. It also avoids the creation of button-hole injuries to either the vascular pedicle or the penile skin. It should make the use of this versatile flap more attractive in the reconstruction of long urethral strictures in those who may wish to use this option for reconstruction of long urethral strictures.

  20. Surgical results of a one-stage combined anterior lumbosacral fusion and posterior percutaneous pedicle screw fixation

    Directory of Open Access Journals (Sweden)

    Chien-Yuan Huang

    2018-01-01

    Full Text Available Objectives: Lumbosacral fusion through either an anterior or a posterior approach to achieve good lordosis and stability is always a challenging surgical operation and is often accompanied by a higher rate of pseudarthrosis than when other lumbar segments are involved. This study evaluated the clinical and radiological results of lumbosacral fusions achieved through a combined anterior and posterior approach. Materials and Methods: From June 2008 to 2012, 20 patients who had L5–S1 instability and stenosis were consecutively treated, first by anterior interbody fusion using an allogenous strut bone graft through the pararectus approach and then by posterior pedicle screw fixation. A minimum of 1-year of clinical and radiological follow-up was conducted. Intraoperative blood loss, surgical time, and any surgery-related complications were recorded. Clinical outcomes were assessed using a visual analog scale (VAS and the patient's Oswestry Disability Index (ODI score. After 1 year, radiological outcomes were assessed by analyzing pelvic incidence, lumbar lordosis, and segmental lordosis using static plain films, while fusion stability was assessed using dynamic plain films. Results: The mean operative time and blood loss were 215 min and 325 cc, respectively. After 1 year, the VAS and ODI scores had significantly improved, and stable fusion with good lordotic curvature was obtained in all cases. Conclusion: The surgical results of the combined procedure are satisfactory in terms of the functional and radiological outcomes. Our method offers advantages regarding both anterior fusion and posterior fixation.

  1. Surgical reconstruction with pedicle flap of advance after excision of facial melanoma in a dog - Case report

    Directory of Open Access Journals (Sweden)

    Bruna Bristot Colombo

    2016-06-01

    Full Text Available ABSTRACT. Colombo B.B., Kuci C.C., Gehrcke M.I., de Souza L.P., Colodel M.M., Gerber J., Salbego F.Z., de Moraes A.N. & Oleskovicz N. [Surgical reconstruction with pedicle flap of advance after excision of facial melanoma in a dog - Case report.] Reconstrução cirúrgica com retalho pediculado de avanço após exérese de melanoma cutâneo facial em um cão - Relato de caso. Revista Brasileira de Medicina Veterinária, 38(2:128-132, 2016. Programa de Pós- -Graduação em Ciência Animal, Universidade do Estado de Santa Catarina, Av. Luís de Camões, 2090, Conta Dinheiro, Lages, SC 88520-000, Brasil. E-mail: brucolombo@hotmail.com The reconstructive surgery has been growing in veterinary medicine, whether in reconstruction tissue caused by trauma or even when there is an extensive tumor resection. This report aims to discuss about a female dog, assisted at the Teaching Hospital of an Educational Institution, which had an ulcerated nodule in the lateral portion of nasal flow plan, with suggestive diagnosis of malignant melanoma, concluded through cytology and referred for surgery. After resection of the tumor, the incision of skin and subcutaneous divulsion for production pedicle flap of advance. After surgery, it was applied with a padded bandage and gauze sheath on the face of the animal. During both the post-operative immediate period and in the following days the retail tissue showed rosy and healthy, with no sign of necrosis or dehiscence. The animal was observed until the day 30 after surgery, where there was local hair growth and good aesthetic appearance, which leads to the conclusion that the pedicle flap advance was an appropriate choice in this case, solving the matter about the animal’s health and looking from the owner’s point of view.

  2. Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model.

    Science.gov (United States)

    Kiyak, Gorkem; Balikci, Tevfik; Heydar, Ahmed Majid; Bezer, Murat

    2018-02-01

    Mechanical study. To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-screw interface. Polyurethane blocks were used to mimic human osteoporotic cancellous bone, and six different screw designs were tested. Five standard and expandable screws without augmentation, eight expandable screws with polymethylmethacrylate (PMMA) or calcium phosphate augmentation, and distal cannulated screws with PMMA and calcium phosphate augmentation were tested. Mechanical tests were performed on 10 unused new screws of each group. Screws with or without augmentation were inserted in a block that was held in a fixture frame, and a longitudinal extraction force was applied to the screw head at a loading rate of 5 mm/min. Maximum load was recorded in a load displacement curve. The peak pullout force of all tested screws with or without augmentation was significantly greater than that of the standard pedicle screw. The greatest pullout force was observed with 40-mm expandable pedicle screws with four fins and PMMA augmentation. Augmented distal cannulated screws did not have a greater peak pullout force than nonaugmented expandable screws. PMMA augmentation provided a greater peak pullout force than calcium phosphate augmentation. Expandable pedicle screws had greater peak pullout forces than standard pedicle screws and had the advantage of augmentation with either PMMA or calcium phosphate cement. Although calcium phosphate cement is biodegradable, osteoconductive, and nonexothermic, PMMA provided a significantly greater peak pullout force. PMMA-augmented expandable 40-mm four-fin pedicle screws had the greatest peak pullout force.

  3. Pedicled Descending Branch Latissimus Dorsi Mini-flap for Repairing Partial Mastectomy Defect: A New Technique

    Directory of Open Access Journals (Sweden)

    Ruizhao Cai, M.D.

    2018-03-01

    Full Text Available Summary:. Volume loss is 1 of the major factors influencing cosmetic outcomes of breast after partial mastectomy (PM, especially for smaller breasts, and therefore, volume replacement is critical for optimizing the final aesthetic outcome. We present a novel technique of raising a pedicled descending branch latissimus dorsi (LD mini-flap for reconstruction of PM defects via an axillary incision. After PM, the LD mini-flap is harvested through the existing axillary incision of the axillary dissection or the sentinel lymph node biopsy. The descending branches of thoracodorsal vessels and nerve are carefully identified and isolated. The transverse branches are protected to maintain muscle innervation and function. The LD muscle is then undermined posteriorly and inferiorly to create a submuscular pocket and a subcutaneous pocket between LD muscle and superficial fascia. Once the submuscular plane is created, the muscle is divided along the muscle fibers from the deep surface including a layer of fat above the muscle. Finally, the LD mini-flap is transferred to the breast defect. Given the limited length and mobility of the LD mini-flap, this approach is best utilized for lateral breast defects. However, for medial defects, the lateral breast tissue is rearranged to reconstruct the medial breast defect, and an LD mini-flap is then used to reconstruct the lateral breast donor site. This technique can therefore be employed to reconstruct all quadrants of the breast and can provide aesthetic outcomes without scars on the back, with minimal dysfunction of LD muscle.

  4. The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study.

    Science.gov (United States)

    Luo, Jiaquan; Wu, Chunyang; Huang, Zhongren; Pan, Zhimin; Li, Zhiyun; Zhong, Junlong; Chen, Yiwei; Han, Zhimin; Cao, Kai

    2017-04-01

    This is a cadaver specimen study to confirm new pedicle screw (PS) entry point and trajectory for subaxial cervical PS insertion. To assess the accuracy of the lateral vertebral notch-referred PS insertion technique in subaxial cervical spine in cadaver cervical spine. Reported morphometric landmarks used to guide the surgeon in PS insertion show significant variability. In the previous study, we proposed a new technique (as called "notch-referred" technique) primarily based on coronal multiplane reconstruction images (CMRI) and cortical integrity after PS insertion in cadavers. However, the PS position in cadaveric cervical segment was not confirmed radiologically. Therefore, the difference between the pedicle trajectory and the PS trajectory using the notch-referred technique needs to be illuminated. Twelve cadaveric cervical spines were conducted with PS insertion using the lateral vertebral notch-referred technique. The guideline for entry point and trajectory for each vertebra was established based on the morphometric data from our previous study. After 3.5-mm diameter screw insertion, each vertebra was dissected and inspected for pedicle trajectory by CT scan. The pedicle trajectory and PS trajectory were measured and compared in axial plane. The perforation rate was assessed radiologically and was graded from ideal to unacceptable: Grade 0 = screw in pedicle; Grade I = perforation of pedicle wall less than one-fourth of the screw diameter; Grade II = perforation more than one-fourth of the screw diameter but less than one-second; Grade III = perforation more than one-second outside of the screw diameter. In addition, pedicle width between the acceptable and unacceptable screws was compared. A total of 120 pedicle screws were inserted. The perforation rate of pedicle screws was 78.3% in grade 0 (excellent PS position), 10.0% in grade I (good PS position), 8.3% in grade II (fair PS position), and 3.3% in grade III (poor PS position). The

  5. A new technique in the surgical treatment of Hangman's fractures: Neurospinal Academy (NSA) technique.

    Science.gov (United States)

    Dalbayrak, Sedat; Yaman, Onur; Yılmaz, Mesut

    2013-07-01

    Treatment of Hangman's fractures is still controversial. Hangman's fractures Type II and IIA are usually treated with surgical procedures. This study aims at describing the Neurospinal Academy (NSA) technique as an attempt to achieve an approximation of the fracture line to the axis body, which may be used for Type II and IIA patients with severe displacement and angulation. NSA technique both pars or pedicle screws are placed bicortically to ensure that anterior surface of C2 vertebral body will be crossed 1-2 mm. A rod is prepared in suitable length and curve to connect the two screws. For placing the rod, sufficient amount of bone is resected from the C2 spinous process. C2 vertebral body is pulled back by means of the screws that crossed the anterior surface of C2 vertebral body. Hangman II and IIA patient are treated with NSA technique. Angulated and tilted C2 vertebral body was pulled back and approximated to posterior elements. In Hangman's fractures Type II and IIA with severe vertebral body and pedicle displacement, NSA technique is an effective and reliable treatment alternative for the approximation of posterior elements to the C2 vertebral body, which is tilted, angulated, and dislocated.

  6. A new technique in the surgical treatment of Hangman′s fractures: Neurospinal Academy (NSA technique

    Directory of Open Access Journals (Sweden)

    Sedat Dalbayrak

    2013-01-01

    Full Text Available Context: Treatment of Hangman′s fractures is still controversial. Hangman′s fractures Type II and IIA are usually treated with surgical procedures. Aim: This study aims at describing the Neurospinal Academy (NSA technique as an attempt to achieve an approximation of the fracture line to the axis body, which may be used for Type II and IIA patients with severe displacement and angulation. Settings and Design: NSA technique both pars or pedicle screws are placed bicortically to ensure that anterior surface of C2 vertebral body will be crossed 1-2 mm. A rod is prepared in suitable length and curve to connect the two screws. For placing the rod, sufficient amount of bone is resected from the C2 spinous process. C2 vertebral body is pulled back by means of the screws that crossed the anterior surface of C2 vertebral body. Materials and Methods: Hangman II and IIA patient are treated with NSA technique. Result: Angulated and tilted C2 vertebral body was pulled back and approximated to posterior elements. Conclusions: In Hangman′s fractures Type II and IIA with severe vertebral body and pedicle displacement, NSA technique is an effective and reliable treatment alternative for the approximation of posterior elements to the C2 vertebral body, which is tilted, angulated, and dislocated.

  7. Journal of Surgical Technique and Case Report

    African Journals Online (AJOL)

    The aim of Journal of Surgical Technique and Case Report is to advance surgical knowledge and practice by promoting the reporting of innovative and reproducible surgical techniques ... Anterior palatal island advancement flap for bone graft coverage: technical note · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  8. Soft Tissue Closure of Grafted Extraction Sockets in the Anterior Maxilla: A Modified Palatal Pedicle Connective Tissue Flap Technique.

    Science.gov (United States)

    El Chaar, Edgard; Oshman, Sarah; Cicero, Giuseppe; Castano, Alejandro; Dinoi, Cinzia; Soltani, Leila; Lee, Yoonjung Nicole

    Localized ridge resorption, the consequence of socket collapse, following tooth extraction in the anterior maxilla can adversely affect esthetics, function, and future implant placement. Immediate grafting of extraction sockets may help preserve natural ridge contours, but a lack of available soft tissue can compromise the final esthetic outcome. The presented modified rotated palatal pedicle connective tissue flap is a useful technique for simultaneous soft tissue coverage and augmentation of grafted sockets to improve esthetic outcome. This article delineates its advantages through the presentation of a four-case series using this new technique.

  9. Liposuction-assisted four pedicle-based breast reduction (LAFPBR): A new safer technique of breast reduction for elderly patients.

    Science.gov (United States)

    La Padula, Simone; Hersant, Barbara; Noel, Warren; Meningaud, Jean Paul

    2018-05-01

    As older people increasingly care for their body image and remain active longer, the demand for reduction mammaplasty is increasing in this population. Only a few studies of reduction mammaplasty have specifically focussed on the outcomes in elderly women. We developed a new breast reduction technique: the Liposuction-Assisted Four Pedicle-Based Breast Reduction (LAFPBR) that is especially indicated for elderly patients. The aim of this paper was to describe the LAFPBR technique and to determine whether it could be considered a safer option for elderly patients compared to the superomedial pedicle (SMP) technique. A retrospective study included sixty-two women aged 60 years and over who underwent bilateral breast reduction mammaplasty. Thirty-one patients underwent LAFPBR and 31 patients were operated using the SMP technique. Complications and patient satisfaction in both groups were analysed. Patient satisfaction was measured using a validated questionnaire: the client satisfaction questionnaire 8 (CSQ-8). The LAFPBR technique required less operating time, and avoided significant blood loss. Six minor complications were observed in SMP patients. No LAFPBR women developed a procedure-related complication. Patient satisfaction was high with a mean score of 29.65 in LAFPBR patients and 28.68 in SMP patients. The LAFPBR is an easy procedure that appears safer than SMP and results in a high satisfaction rate in elderly women. Copyright © 2018 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Prepubertal gonadectomy in cats: different surgical techniques and comparison with gonadectomy at traditional age.

    Science.gov (United States)

    Porters, N; Polis, I; Moons, C; Duchateau, L; Goethals, K; Huyghe, S; de Rooster, H

    2014-09-06

    Feasibility, surgical time and complications of different surgical techniques for prepubertal gonadectomy (PPG; 8-12 weeks of age) in cats were studied and compared to gonadectomy at traditional age (TAG; 6-8 months of age). Kittens were randomly assigned to PPG or TAG. Ovarian pedicle haemostasis for PPG was achieved by ligatures (n=47), vascular clips (n=50), bipolar electrocoagulation (n=50), or pedicle tie (n=50); for TAG (n=34) ligatures were used. In male cats, PPG consisted of closed castration by spermatic cord knot (n=92) or ligature (n=91) while TAG (n=34) was an open castration by spermatic cord knot. A linear (surgical time) and a logistic regression (complications) model were designed. Significance was set at 0.05. For female PPG, clips and coagulation were the fastest procedures; placement of ligatures was most time-consuming. In male PPG, knot placement was significantly faster than ligation. In both sexes, very few intraoperative or wound complications were observed, irrespective of the surgical technique used. Surgical times in females (ligatures) as well as in males (knot) were significantly shorter for PPG than for TAG. PPG was as safe as TAG, yet took less time to perform and did not result in a greater rate of postoperative complications. British Veterinary Association.

  11. Pedicled perforator flaps

    DEFF Research Database (Denmark)

    Demirtas, Yener; Ozturk, Nuray; Kelahmetoglu, Osman

    2009-01-01

    Described in this study is a surgical concept that supports the "consider and use a pedicled perforator flap whenever possible and indicated" approach to reconstruct a particular skin defect. The operation is entirely free-style; the only principle is to obtain a pedicled perforator flap...... to reconstruct the defect. The perforators are marked with a hand-held Doppler probe and multiple flaps are designed. The appropriate flap is elevated after identifying the perforator(s). Dissection of the perforator(s) or complete incision of the flap margins are not mandatory if the flap is mobilized...... adequately to cover the defect. Defects measuring 3 x 3 cm up to 20 x 20 cm at diverse locations were successfully reconstructed in 20 of 21 patients with 26 flaps. Pedicled perforator flaps offer us reliable and satisfactory results of reconstruction at different anatomic territories of the body. It sounds...

  12. Study on pedicle screw fixation of cervical spine assisted CT-based navigation system compared with the individual cervical peddle screws placement technique

    International Nuclear Information System (INIS)

    He Xishun; Yang Huilin; Zhu Ruofu; Tan Xiangqi; Wang Genlin; Tang Tiansi

    2008-01-01

    Objective: To explore a safe and effective method for placing the cervical pedicle screws. Methods: There were ten adult cadaver specimens of cervica spine (C 1 -C 7 ) with intact structures including ligament and perivertebral muscles. The spiral computed tomography scan (Elscint CT Twin flash) at the section of 1 mm and three-dimensional reconstruction of all 10 cervical specimens were taken. By CT scan, the parameters of the cervical pedicles were measure,Then taking randomly 5 cervical specimens, according to the CT measurements, an appropriate screw was inserted into pedicle individually. In the other 5 human cadaver cervical vertebraes, Φ3.5 mm screws were inserted into the C 2 -C 7 pedicles by assisted by CT-based navigation system. Cortical integrity of every sample was examined by anatomic dissection, the spiral computed tomography scan and arrows,and coronal reconstruction. Results: Sixty screws was inserted into pedicle individually, and the achievement ratio was 90%, the perfectness ratio was 75%, 60 screws was placed into pedicle assisted by CT-based navigation system, and the achievement ratio was 96.6%, the perfectness ratio was 90%. By chi-square test for statistical analysis, there were no statistical significance between the accuracy rate of two methods(P>0.05). However there was statistical significance between the perfectness ratio between two methods(P<0.05). Conclusion: Compared with the individual cervical peddle screws placement technique, the perfectness ratio of pedicle screw fixation of cervical spine assisted by CT-based navigation system is higher, but there are no significant difference in accuracy. (authors)

  13. Changes in urological surgical techniques

    Directory of Open Access Journals (Sweden)

    Oktay Üçer

    2010-06-01

    Full Text Available Recently, laparoscopic and afterwards robotic techniques have constituted most of urologic surgery procedures. Open surgery may give place to robotic surgery due to possible widespread use of robots in the future. Studies, that compare these two techniques are usually designed about radical prostatectomy, since it is the most common operation performed by using these techniques. In literature,robotic surgery seems more advantageous than other techniques but the most important disadvantage of this technique is cost-effective problems. In present review,history of open, laparoscopic and robotic surgery, and comparison of advantages, disadvantages and cost of these techniques have been discussed with literature.

  14. Severe Gynecomastia: New Technique Using Superior Pedicle NAC Flap Through a Circumareolar Approach.

    Science.gov (United States)

    Ibrahiem, Saad Mohamed Saad

    2016-06-01

    : Gynecomastia is defined as benign proliferation of glandular breast tissue in men. Gynecomastia causes considerable emotional discomfort because of limitation of everyday activity especially in young men. Surgical treatment of gynecomastia significantly contributes to an increase in social activity and an improvement of social acceptance and emotional comfort, and thus significantly improves satisfaction from personal life in men who underwent this intervention. Various surgical techniques were suggested to treat gynecomastia, but most of them end with visible scars especially in severe degree gynecomastia. The aim of many plastic surgeons is to advocate new techniques treating severe gynecomastia (grade II B and III according to Simon et al) with less visible scars. The author proposed a new technique combining both surgery and liposuction for treating grade II B and III gynecomastia using only circumareolar approach. This study evaluates aesthetic results after surgery and assessment of the incidence of early and late postoperative complications. The patient was marked preoperatively while standing. Under general anesthesia, ultrasound-assisted liposuction of the periglandular area and de-epithelialization of excess skin were performed. A superiorly based nipple areola complex flap was created based on the subdermal plexus. The excess glandular tissue was resected through the lower half of the circle of the de-epithelialized area. Closure of the wound was done after insertion of 14-French redivac. This treatment protocol was applied to 27 patients, 18 to 53 years of age, from February 2008 till now. Among these patients, 4 were classified as type IIB and 23 as type III. Follow-up ranged from 3 months to 4 years. Complications were the following: 1 hematoma, 1 wound dehiscence, 1 loss of nipple areola complex, 2 cases of hypertrophied scars, and 3 minor aesthetic problems near areolae. A new periareolar approach for correction of severe-grade gynecomastia

  15. "TuNa-saving" endoscopic medial maxillectomy: a surgical technique for maxillary inverted papilloma.

    Science.gov (United States)

    Pagella, Fabio; Pusateri, Alessandro; Matti, Elina; Avato, Irene; Zaccari, Dario; Emanuelli, Enzo; Volo, Tiziana; Cazzador, Diego; Citraro, Leonardo; Ricci, Giampiero; Tomacelli, Giovanni Leo

    2017-07-01

    The maxillary sinus is the most common site of sinonasal inverted papilloma. Endoscopic sinus surgery, in particular endoscopic medial maxillectomy, is currently the gold standard for treatment of maxillary sinus papilloma. Although a common technique, complications such as stenosis of the lacrimal pathway and consequent development of epiphora are still possible. To avoid these problems, we propose a modification of this surgical technique that preserves the head of the inferior turbinate and the nasolacrimal duct. A retrospective analysis was performed on patients treated for maxillary inverted papilloma in three tertiary medical centres between 2006 and 2014. Pedicle-oriented endoscopic surgery principles were applied and, in select cases where the tumour pedicle was located on the anterior wall, a modified endoscopic medial maxillectomy was carried out as described in this paper. From 2006 to 2014 a total of 84 patients were treated. A standard endoscopic medial maxillectomy was performed in 55 patients (65.4%), while the remaining 29 (34.6%) had a modified technique performed. Three recurrences (3/84; 3.6%) were observed after a minimum follow-up of 24 months. A new surgical approach for select cases of maxillary sinus inverted papilloma is proposed in this paper. In this technique, the endoscopic medial maxillectomy was performed while preserving the head of the inferior turbinate and the nasolacrimal duct ("TuNa-saving"). This technique allowed for good visualization of the maxillary sinus, good oncological control and a reduction in the rate of complications.

  16. Comparison of Direct Pars Repair Techniques of Spondylolysis in Pediatric and Adolescent Patients: Pars Compression Screw Versus Pedicle Screw-Rod-Hook.

    Science.gov (United States)

    Karatas, Ali F; Dede, Ozgur; Atanda, Alfred A; Holmes, Larry; Rogers, Kenneth; Gabos, Peter; Shah, Suken A

    2016-08-01

    Retrospective clinical cohort study. To compare the clinical and radiographic outcomes of patients who were treated with intrasegmental pars fixation by either laminar compression screw (LS) or a pedicle screw, rod, and laminar hook (PSRH) construct. Spondylolysis is a nonunion defect of the pars interarticularis. In symptomatic spondylolysis, direct repair of the pars interarticularis defect can preserve motion and prevent abnormal stresses at the adjacent levels. Sixteen patients who failed nonoperative treatment and underwent direct pars repair by using LS (n=9) or PSRH (n=7) constructs were included in the study. Clinical outcome was assessed by using the MacNab criteria. Radiologic fusion and complications were evaluated using plain radiographs or computed tomography images and patient charts. The healing rate was 100% after 6 months. The healing time was similar in both the groups: LS, 6.5 months; PSRH, 6.2 months. Patients with PSRH (5.9 mo) were more likely to return to sports earlier relative to patients with LS (7.7 mo). There were no complications in the LS group; in the PSRH group, 1 patient had mild sensory deficit and 2 had superficial wound infections. The MacNab criteria for pain assessment showed an excellent or good outcome in 8 of 9 patients in LS group and 6 of 7 patients in PSRH group. Relative to LS patients, there was a significant increase in surgical time and estimated blood loss among PSRH patients. Either of the mentioned 2 techniques appears to produce acceptable results. Biplanar fluoroscopy and navigation systems could minimize the risk of screw misplacement with LS construct. Familiarity with the various fixation techniques will allow the surgeon to select the most appropriate surgical technique.

  17. Hyperbaric oxygen therapy and surgical delay improve flap survival of reverse pedicle flaps for lower third leg and foot reconstruction

    Directory of Open Access Journals (Sweden)

    Pradeoth Mukundan Korambayil

    2015-06-01

    Full Text Available Aim: The purpose of the study is to present a management protocol for various types of soft tissue defects of the distal third region of leg and foot treated with pedicle flaps, by including hyperbaric oxygen (HBO therapy in the treatment regimen with flap delay. Methods: We present a prospective study of 23 patients with various types of soft tissue defects of the foot, and lower third of leg managed in our institution from December 2012 to December 2013. All soft tissue defects were treated by a reverse pedicle flap. Twelve patients were managed with flap delay with HBO therapy and 11 patients with immediate flaps without HBO therapy. The postoperative period, hospital course, and follow-up were documented. Results: Of 12 patients with flap delay and HBO, 10 patients did not suffer any complications secondary to flap transfer. One patient had discoloration of the tip of the flap, which settled without the intervention, and 1 patient had recurrent abscess formation, which required debridement and closure. Of 11 patients with direct transfer, 6 patients presented with complications including flap congestion, partial flap loss, and tip necrosis, which required secondary intervention. Conclusion: HBO therapy is a useful adjunct in flap delay of the reverse pedicle flap for soft tissue reconstruction of the lower third of the leg and foot regions.

  18. Usefulness and radiological evaluation of accuracy of innovative "Smart" hand technique for pedicle screw placement: an anatomical study.

    Science.gov (United States)

    Comert, Ayhan; Dogan, İhsan; Çaglar, Y Sukru

    2017-11-01

    The aim of this study is to use a smartphone application during pedicle screw placement navigation and examine the accuracy of this application on anatomical dry vertebrae model. 76 dry vertebrae were used for this study and pedicle entry points, projections of pedicle screw trajectory lines in lateral and superior aspect of vertebral body were identified and drawn for each vertebra bilaterally. In each position, all angulations were measured directly before the procedure manually. 152 pedicle screws were inserted as a simulation of screw placement with the guidance of angle-meter smart app. Accuracy of the method was tested according to the occurrence of bone penetration and angular deviation of the inserted screws was evaluated in computed tomography images. Mean deviation of pedicle screws of 76 pedicle screws in right side in horizontal plane was measured 2.30°±1.78°; in sagittal plane 2.17°±1.57° and in left side in horizontal plane 3.01°±1.83°; in sagittal plane 2.38°±1.68°. No bone penetration was occurred during 152 pedicle screw placements. According to the t-test results, there were significant differences between two groups in craniocaudal direction of the right side pedicle screws and in craniocaudal direction of left side pedicle screws. The free smartphone application presented here as angle-meter can be interpreted as a safe digital device for spinal instrumentation procedures. As a prototype of future pedicle screw fixation systems, it should be improved in terms of its feasibility and compatibility with screw probes. This may lead to apply mobile digital angle meter in spinal procedure.

  19. Problems associated with basic oral surgical techniques

    International Nuclear Information System (INIS)

    Kapatkin, A.S.; Marretta, S.M.; Schloss, A.J.

    1990-01-01

    The veterinarian must be able to diagnose several types of dental problems. History, physical examination, clinical pathology, and radiography are important in making an accurate diagnosis. Basic oral surgery includes various extraction techniques and management of their associated complications. Knowledge of dental anatomy and proper surgical technique can make an extraction curative rather than a frustrating procedure with multiple complications

  20. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.

    Science.gov (United States)

    Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo

    2018-01-01

    OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT screw fixation

  1. Adjacent-segment disease after thoracic pedicle screw fixation.

    Science.gov (United States)

    Agarwal, Nitin; Heary, Robert F; Agarwal, Prateek

    2018-03-01

    OBJECTIVE Pedicle screw fixation is a technique widely used to treat conditions ranging from spine deformity to fracture stabilization. Pedicle screws have been used traditionally in the lumbar spine; however, they are now being used with increasing frequency in the thoracic spine as a more favorable alternative to hooks, wires, or cables. Although safety concerns, such as the incidence of adjacent-segment disease (ASD) after cervical and lumbar fusions, have been reported, such issues in the thoracic spine have yet to be addressed thoroughly. Here, the authors review the literature on ASD after thoracic pedicle screw fixation and report their own experience specifically involving the use of pedicle screws in the thoracic spine. METHODS Select references from online databases, such as PubMed (provided by the US National Library of Medicine at the National Institutes of Health), were used to survey the literature concerning ASD after thoracic pedicle screw fixation. To include the authors' experience at Rutgers New Jersey Medical School, a retrospective review of a prospectively maintained database was performed to determine the incidence of complications over a 13-year period in 123 consecutive adult patients who underwent thoracic pedicle screw fixation. Children, pregnant or lactating women, and prisoners were excluded from the review. By comparing preoperative and postoperative radiographic images, the occurrence of thoracic ASD and disease within the surgical construct was determined. RESULTS Definitive radiographic fusion was detected in 115 (93.5%) patients. Seven incidences of instrumentation failure and 8 lucencies surrounding the screws were observed. One patient was observed to have ASD of the thoracic spine. The mean follow-up duration was 50 months. CONCLUSIONS This long-term radiographic evaluation revealed the use of pedicle screws for thoracic fixation to be an effective stabilization modality. In particular, ASD seems to be less of a problem in the

  2. Journal of Surgical Technique and Case Report: Editorial Policies

    African Journals Online (AJOL)

    Focus and Scope. The aim of Journal of Surgical Technique and Case Report is to advance surgical knowledge and practice by promoting the reporting of innovative and reproducible surgical techniques and illustrative surgical cases on various surgical disciplines. The journal encourages authoritative synthesis of current ...

  3. Técnica de doble pedículo lateral en reconstrucción mamaria después de tumorectomía Double lateral pedicle technique in breast reconstruction after tumorectomy

    Directory of Open Access Journals (Sweden)

    Orlando Rafael Expósito Reyes

    2007-12-01

    Full Text Available Los tumores mamarios aparecen cada vez con mayor frecuencia, e igualmente las secuelas poco estéticas de la cirugía de estos. Se presenta la técnica quirúrgica de doble pedículo externo (superior e inferior en la reconstrucción mamaria después de una tumorectomía por fibroadenoma gigante de la mama izquierda. Se planificó la intervención tomando como referencia la técnica de Skoog (pedículo lateral externo, por la localización, el área ocupada por la masa mamaria (3/4 partes de la mama y para conservar la irrigación del complejo areola-pezón. Para llenar el vacío dejado por el tumor, se utilizó un segundo pedículo inferolateral que se liberó, rotó y fijó a la fascia muscular, con sutura no absorbible, en el área del cuadrante superior interno, lo cual sirvió de relleno o apoyo al complejo areola-pezón y a su pedículo. Se obtuvo un resultado estético bueno, que satisfizo las expectativas de la paciente y de los médicos, al conservarse la mama y su forma.Breast tumors are more and more frequent, as well as the little aesthetic sequelae of their surgery. The external double pedicle surgical technique (upper and lower in breast reconstruction after a tumorectomy due to giant fibroadenoma of the left breast was presented. The operation was planned taking Skoog’s technique as a reference (external lateral pedicle by the localization, the area occupied by the breast mass (3/4 parts of the breast and to preserve the irrigation of the areola-nipple complex. To fill the gap left by the tumor, it was used a second inferolateral pedicle that was released, rotated and fixed to the muscle fascia with non-absorbable suture in the area of the upper internal quadrant that served as a filling or support to the areola-nipple complex and to its pedicle. A good aesthetic result that satisfied the patients and specialists’ expectations was obtained on conserving the breast and its form.

  4. The pullout performance of pedicle screws

    CERN Document Server

    Demir, Teyfik

    2015-01-01

    This brief book systematically discusses all subjects that affect the pullout strength of pedicle screws. These screws are used in spinal surgeries to stabilize the spine. The holding strength of the pedicle screw is vital since loosening of the pedicle screws can cause revision surgeries. Once the pedicle screw is pulled out, it is harder to obtain same stabilization for the fused vertebrae. The book reviews the effect of screw designs, application techniques, cement augmentation, coating of the screw and test conditions on the pullout strength. The studies with finite element analysis were also included.

  5. Pedicled Gastrocnemius Flap: Clinical Application in Limb Sparing Surgical Resection of Sarcoma Around the Knee Region and Popliteal Fossa

    International Nuclear Information System (INIS)

    EL-SHERBINY, M.

    2008-01-01

    To highlight on the versatility of superiorly based pedicled gastrocnemius muscle flap in the limb-sparing surgery for bone or soft tissue sarcoma around the knee and popliteal fossa. Patients and Methods: A total of 30 patients with localized bone or soft tissue sarcoma around the knee and popliteal fossa were treated with limb-salvage procedure. The study included 5 cases with bone sarcoma of the distal femur, 15 cases having bone sarcoma of proximal tibia and 10 cases having soft tissue sarcoma around the knee region and popliteal fossa. Routine preoperative staging studies were done for every patient and included local plain radiography, local MRI, isotopic bone scan and CT chest. Local MRA or angiography was done in selected cases. According to the Enneking staging system, 19 patients had stage IIB and 11 had stage IIA. Patients having bone sarcoma of the proximal tibia were subjected to wide resection, endo prosthetic reconstruction and reconstruction of the extensor mechanism by the medial gastrocnemius muscle flap. Patients having bone sarcoma of the distal femur were subjected to wide resection, endo prosthetic reconstruction and coverage of the prosthesis and re balance of the patellar tendon by the medial gas-trocnemius flap. Patients having soft tissue sarcoma were subjected to wide resection and soft tissue coverage with either medial or lateral myocutaneous gastrocnemius flap or muscle flap with grafting. Limb function was evaluated according to MSTS functional scores. Adjuvant chemotherapy or radiotherapy was given according to nationally agreed protocols. Results: There were 18 males and 12 females with a mean age of 29 years at the time of surgery (range 11-44 years). The mean follow-up period was 52 months (range 25-72 months). Resection with a negative bony and soft tissue margins could be achieved in all cases. A total of 30 flaps were used and included medial gastrocnemius muscle flaps in 21 cases (15 cases had proximal tibia endoprothesis, 5

  6. Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique.

    Science.gov (United States)

    Jin, Mengran; Liu, Zhen; Liu, Xingyong; Yan, Huang; Han, Xiao; Qiu, Yong; Zhu, Zezhang

    2016-06-01

    To assess the accuracy of O-arm-navigation-based pedicle screw insertion in dystrophic scoliosis secondary to NF-1 and compare it with free-hand pedicle screw insertion technique. 32 patients with dystrophic NF-1-associated scoliosis were divided into two groups. A total of 92 pedicle screws were implanted in apical region (two vertebrae above and below the apex each) in 13 patients using O-arm-based navigation (O-arm group), and 121 screws were implanted in 19 patients using free-hand technique (free-hand group). The postoperative CT images were reviewed and analyzed for pedicle violation. The screw penetration was divided into four grades: grade 0 (ideal placement), grade 1 (penetration 4 mm). The accuracy rate of pedicle screw placement (grade 0, 1) was significantly higher in the O-arm group (79 %, 73/92) compared to 67 % (81/121) of the free-hand group (P = 0.045). Meanwhile, a significantly lower prevalence of grade 2-3 perforation was observed in the O-arm group (21 vs. 33 %, P arm navigation compared to free-hand technique (2 vs. 15 %, P arm navigation (58 vs. 42 %, P arm-based pedicle screw placement in dystrophic NF-1-associated scoliosis. O-arm navigation system does facilitate pedicle screw insertion in dystrophic NF-1-associated scoliosis, demonstrating superiorities in the safety and accuracy of pedicle screw placement in comparison with free-hand technique.

  7. Hemorrhoidectomy: pedicle ligation vs pedicle coagulation

    International Nuclear Information System (INIS)

    Shaikh, B.S.; Balaoch, I.B.; Sohu, K.M.

    2015-01-01

    Objective: To compare the outcome of pedicle ligation vs pedicle coagulation haemorrhoidectomy. Methodology: This comparative prospective study was carried out at Department of Surgery, Ghulam Muhammad Maher Medcial College Hospital, Sukkur, Pakistan from January 2011 to January 2013 and included 300 patients of hemorrhoids. After routine workup, patients were randomly divided into two equal groups with one group receiving pedicle ligation and other pedicle coagulation for hemorrhoidectomy. Postoperatively they were followed for a period of 8 weeks for complications including pain, urinary retention, bleeding and anal stricture. Pain was recorded up to 10th postoperative day on the basis of visual analogue scale. Results: Mean age was 45 years and male to female ratio was 1.7:1. Mean operative time in pedicle ligation group was 15 min (range 14-20 min) and 17 min (15-25 min) in pedicle coagulation group. In Pedicle ligation group, pain was worst in 35 patients, moderate in 85 and mild in 30 patients; on the other hand in pedicle coagulation group, just 09 patients experienced worst pain. Urinary retention was observed in 44 patients in pedicle ligation group and 19 in pedicle coagulation group. Five patients in pedicle ligation group developed bleeding after their discharge from hospital; 7 patients in pedicle coagulation group reported secondary bleeding. Anal stricture was a rare complication and was found equally common in both the groups. Conclusion: Conventional hemorrhoidectomy with pedicle coagulation is an effective treatment modality for hemorrhoids and is associated with less chance of postoperative anal pain and urinary retention. (author)

  8. Positioning of pedicle screws in adolescent idiopathic scoliosis using electromyography

    Directory of Open Access Journals (Sweden)

    Bruno Moreira Gavassi

    2015-06-01

    Full Text Available OBJECTIVE: To analyze the occurrence of poor positioning of pedicle screws inserted with the aid of intraoperative electromyographic stimulation in the treatment of Adolescent Idiopathic Scoliosis (AIS.METHODS: This is a prospective observational study including all patients undergoing surgical treatment for AIS, between March and December 2013 at a single institution. All procedures were monitored by electromyography of the inserted pedicle screws. The position of the screws was evaluated by assessment of postoperative CT and classified according to the specific AIS classification system.RESULTS: Sixteen patients were included in the study, totalizing 281 instrumented pedicles (17.5 per patient. No patient had any neurological deficit or complaint after surgery. In the axial plane, 195 screws were found in ideal position (69.4% while in the sagittal plane, 226 screws were found in ideal position (80.4%. Considering both the axial and the sagittal planes, it was observed that 59.1% (166/281 of the screws did not violate any cortical wall.CONCLUSION: The use of pedicle screws proved to be a safe technique without causing neurological damage in AIS surgeries, even with the occurrence of poor positioning of some implants.

  9. Coblation versus other surgical techniques for tonsillectomy.

    Science.gov (United States)

    Pynnonen, Melissa; Brinkmeier, Jennifer V; Thorne, Marc C; Chong, Lee Yee; Burton, Martin J

    2017-08-22

    Tonsillectomy is a very common operation and is performed using various surgical methods. Coblation is a popular method because it purportedly causes less pain than other surgical methods. However, the superiority of coblation is unproven. To compare the effects of coblation tonsillectomy for chronic tonsillitis or tonsillar hypertrophy with other surgical techniques, both hot and cold, on intraoperative morbidity, postoperative morbidity and procedural cost. The Cochrane ENT Information Specialist searched the ENT Trials Register; Central Register of Controlled Trials (CENTRAL 2017, Issue 3); PubMed; Ovid Embase; CINAHL; Web of Science; ClinicalTrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 20 April 2017. Randomised controlled trials (RCTs) of children and adults undergoing tonsillectomy with coblation compared with any other surgical technique. This review is limited to trials of extracapsular (traditional) tonsillectomy and excludes trials of intracapsular tonsil removal (tonsillotomy). We used the standard Cochrane methods. Our primary outcomes were: patient-reported pain using a validated pain scale at postoperative days 1, 3 and 7; intraoperative blood loss; primary postoperative bleeding (within 24 hours) and secondary postoperative bleeding (more than 24 hours after surgery). Secondary outcomes were: time until resumption of normal diet, time until resumption of normal activity, duration of surgery and adverse effects including blood transfusion and the need for reoperation. We used GRADE to assess the quality of the evidence for each outcome; this is indicated in italics. We included 29 studies, with a total of 2561 participants. All studies had moderate or high risk of bias. Sixteen studies used an adequate randomisation technique, however the inability to mask the surgical teams and/or provide adequate methods to mitigate the risk of bias put nearly all studies at moderate or high risk of

  10. Root coverage in class I gingival recession defects, combining rotated papillary pedicle graft and coronally repositioned flap, using a micro surgical approach: A clinical evaluation

    Directory of Open Access Journals (Sweden)

    Latha Tella

    2009-01-01

    Full Text Available Background: The purpose of this case study was to evaluate the success and predictability of a rotated papillary pedicle graft in combination with the coronally advanced flap using surgical loupe (2.5X magnification for the treatment of Miller′s class I gingival recession. Materials and Methods: Fifteen systemically healthy patients with isolated gingival recession underwent the procedure. The probing depth, percentage root coverage, width of the keratinized gingiva and the gain in clinical attachment, papilla width, papilla height, area of the papilla at the donor site, were recorded at baseline, 3 months and 12 months. Results: All parameters except probing pocket depth, significantly improved from baseline to 12 months. The mean recession defect of 2.67 ± 0.03 mm present at baseline reduced to 0.13 ± 0.35 mm at the end of the 3 rd months and stabilized at 0.27 ± 0.59 mm at 12 months. The mean reduction in recession depth was 2.40 ± 0.03 mm at the end of the study. Complete recession coverage was obtained in 13 of the 15 (87% of the cases treated with a mean percentage recession coverage at 12 months being 86 ± 35.19%. The gain in the width of the keratinized gingiva was 1.33 ± 0.13 mm at the end of the study. There was no postoperative morbidity from where the graft was harvested at the end of the study period. Conclusion: The use of magnification in mucogingival surgery resulted in achieving a high degree of success and predictability as well as an excellent esthetic outcome.

  11. Posterior Fixation with Unilateral Same Segment Pedicle Fixation and Contralateral Hook in Surgical Treatment of Thoracolumbar Burst Fractures

    Directory of Open Access Journals (Sweden)

    Farzad Omidi-Kashani

    2016-06-01

    Full Text Available Background In surgical treatment of thoracolumbar burst fractures, most authors try to lower the number of vertebrae involved during the surgery. Objectives The aim of this study was to evaluate the outcome of a medium-segment posterior spinal fixation in these patients. Patients and Methods We retrospectively reviewed 27 patients (18 male, 9 female with mean age of 39.4 ± 15.0 years old in a before-and-after study. The mean follow-up period was 38.4 ± 15.6 months. We involved 2 intact above vertebrae and one intact below vertebra, inserting a pedicular screw at the fractured level and supplemented the construct with contralateral infralaminar hook. Clinical and radiologic characteristics were assessed with American spinal injury association (ASIA scale, oswestry disability index (ODI, visual analogue scale (VAS, and plain radiography. Data analysis was carried out by SPSS version 11.5 software. Results Mean post traumatic kyphosis was + 15.7° ± 3.3° that was changed to - 8.5° ± 4.3° and +1° ± 4.4° at immediate and last visit after surgery, respectively. Mean loss of correction (LOC was 9.5° ± 1.9° (P < 0.001. At the most recent follow-up visit, mean ODI and VAS were 15.0 ± 14.4 and 2.4 ± 2.5, respectively and 24 cases (88.9% declared excellent or good clinical results. At the last follow-up visit, LOC had no significant correlation neither with VAS nor ODI. Conclusions In surgical treatment of thoracolumbar burst fractures, a medium-segment posterior spinal fixation, although cannot maintain the radiologic reduction of the fractured vertebrae efficiently, is not only associated with acceptable clinical outcome but also spare one lower intact lumbar segment and therefore recommended.

  12. Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients

    Science.gov (United States)

    Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul

    2013-01-01

    In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276

  13. Finger replantation: surgical technique and indications.

    Science.gov (United States)

    Barbary, S; Dap, F; Dautel, G

    2013-12-01

    In this article, we discuss the surgical technique of finger replantation in detail, distinguishing particularities of technique in cases of thumb amputation, children fingertip replantation, ring finger avulsion, and very distal replantations. We emphasize the principles of bone shortening, the spare part concept, the special importance of nerve sutures and the use of vein graft in case of avulsion or crushing. However, even if finger replantation is now a routine procedure, a clear distinction should be made between revascularization and functional success. The indications for finger replantation are then detailed in the second part of this paper. The absolute indications for replantation are thumb, multiple fingers, transmetacarpal or hand, and any upper extremity amputation in a child whatever the level. Fingertip amputations distal to the insertion of the Flexor digitorum superficialis (FDS) are also a good indication. Other cases are more controversial because of the poor functional outcome, especially for the index finger, which is often functionally excluded. Copyright © 2013. Published by Elsevier SAS.

  14. Versatility of Pedicled Tensor Fascia Lata Flap: A Useful and Reliable Technique for Reconstruction of Different Anatomical Districts

    Directory of Open Access Journals (Sweden)

    Md. Sohaib Akhtar

    2014-01-01

    Full Text Available Aims and Objectives. The aim of this study was to evaluate the versatility of pedicled tensor fascia lata flap for reconstruction of various anatomical regions. Materials and Methods. In this retrospective study a total of 34 patients with defects over various anatomical regions were included. The defects were located over the trochanter (n=12, groin (n=8, perineum (n=6, lower anterior abdomen (n=6, gluteal region (n=1, and ischial region (n=1. The etiology of defects included trauma (n=12, infection (n=8, pressure sores (n=8, and malignancy (n=6. Reconstruction was performed using pedicled tensor fascia lata flaps. Patients were evaluated in terms of viability of the flap and donor site morbidity. The technical details of the operative procedure have also been outlined. Results. All the flaps survived well except 5 patients in which minor complications were noted and 1 who experienced complete flap loss. Of those with minor complications, 1 patient developed distal marginal necrosis and 1 developed infection which subsided within three days by dressings and antibiotics and in 2 patients partial loss of the skin graft occurred at the donor site out of which 1 required regrafting and another one healed completely with dressing and antibiotics. All the patients were followed up for an average period of 6 months, ranging from 1 to 12 months. Donor site morbidity was minimal. Conclusion. It was concluded that the pedicled tensor fascia lata flap is a versatile, reliable, easy, and less time consuming procedure for the coverage of defects around trochanter, groin, lower anterior abdomen, perineum, and ischial region.

  15. Evolving Educational Techniques in Surgical Training.

    Science.gov (United States)

    Evans, Charity H; Schenarts, Kimberly D

    2016-02-01

    Training competent and professional surgeons efficiently and effectively requires innovation and modernization of educational methods. Today's medical learner is quite adept at using multiple platforms to gain information, providing surgical educators with numerous innovative avenues to promote learning. With the growth of technology, and the restriction of work hours in surgical education, there has been an increase in use of simulation, including virtual reality, robotics, telemedicine, and gaming. The use of simulation has shifted the learning of basic surgical skills to the laboratory, reserving limited time in the operating room for the acquisition of complex surgical skills". Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Traumatic Fracture of Thin Pedicles Secondary to Extradural ...

    African Journals Online (AJOL)

    sequelae, secondary to local mass effect. Our objective is to report a technical case report, illustrating a traumatic spinal injury with multiple pedicle fractures, secondary to atrophic lumbar pedicles as well as the diagnostic workup and surgical management of this problem. Posterior lumbar decompression, resection of the ...

  17. Long-term follow-up and patient satisfaction after reduction mammoplasty: Superomedial versus inferior pedicle

    Directory of Open Access Journals (Sweden)

    Mohamed Makboul

    2016-01-01

    Full Text Available Background: Surgery for hypertrophied breasts represents a challenge for plastic surgeons. The search for a good post-surgical cosmetic breast has led to the development of many techniques. Objectives for reduction mammoplasty are to achieve elevated, symmetrical breasts, a round shape, good projection, small cicatrices that are not very perceptible, and a lasting result. Patients and Methods: This study was carried out on sixty cases who had done reduction mammoplasty from January 2009 to December 2014. All patients were examined and were asked for late post-operative results and overall patients' satisfaction. Results: Long-term projection and contour of the breast were more satisfactory among patients who had superomedial pedicle with a statistically significant difference. No statistically significant difference was observed between patients underwent either superomedial or inferior pedicle reduction mammoplasty with regard to breast shape symmetry, nipple symmetry and sensation. The mean score for satisfaction was higher among patients who underwent superomedial pedicle rather than the inferior pedicle method. Conclusion: The superomedial pedicle shows better long-term cosmetic results.

  18. [The sural medial perforator flap: Anatomical bases, surgical technique and indications in head and neck reconstruction].

    Science.gov (United States)

    Struk, S; Schaff, J-B; Qassemyar, Q

    2018-04-01

    The medial sural artery perforator (MSAP) flap is defined as a thin cutaneo-adipose perforator flap harvested on the medial aspect of the leg. The aims of this study were to describe the anatomical basis as well as the surgical technique and discuss the indications in head and neck reconstructive surgery. We harvested 10 MSAP flap on 5 fresh cadavers. For each case, the number and the location of the perforators were recorded. For each flap, the length of pedicle, the diameter of source vessels and the thickness of the flap were studied. Finally, we performed a clinical application of a MSAP flap. A total of 23 perforators with a diameter superior than 1mm were dissected on 10 legs. The medial sural artery provided between 1 and 4 musculocutaneous perforators. Perforators were located in average at 10.3cm±2cm from the popliteal fossa and at 3.6cm±1cm from the median line of the calf. The mean pedicle length was 12.1cm±2.5cm. At its origin, the source artery diameter was 1.8mm±0.25mm and source veins diameters were 2.45mm±0.9mm in average. There was no complication in our clinical application. This study confirms the reliability of previous anatomical descriptions of the medial sural artery perforator flap. This flap was reported as thin and particularly adapted for oral cavity reconstruction and for facial or limb resurfacing. Sequelae might be reduced as compared to those of the radial forearm flap with comparable results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Minimally invasive mini open split-muscular percutaneous pedicle screw fixation of the thoracolumbar spine

    Directory of Open Access Journals (Sweden)

    Murat Ulutaş

    2015-03-01

    Full Text Available We prospectively assessed the feasibility and safety of a new percutaneous pedicle screw (PPS fixation technique for instrumentation of the thoracic and lumbar spine in this study. All patients were operated in the prone position under general anesthesia. A 6 to 8 cm midline skin incision was made and wide sub-cutaneous dissection was performed. The paravertebral muscles were first dissected subperiosteally into the midline incision of the fascia for lumbar microdiscectomy with transforaminal lumbar interbody fusion cage implantation. After the secondary paramedian incisions on the fascia, the PPSs were inserted via cleavage of the multifidus muscles directly into the pedicles under fluoroscopy visualization. A total of 35 patients underwent surgery with this new surgical technique. The control group for operative time, blood loss and analgesic usage consisted of 35 randomly selected cases from our department. The control group underwent surgery via conventional pedicle screw instrumentation with paramedian fusion. All patients in the minimal invasive surgery series were ambulatory with minimal pain on the first postoperative day. The operation time and blood loss and the postoperative analgesic consumption were significantly less with this new technique. In conclusion, the minimal invasive mini open split-muscular percutaneous pedicle screw fixation technique is safe and feasible. It can be performed via a short midline skin incision and can also be combined with interbody fusion, causing minimal pain without severe muscle damage.

  20. Computer-Assisted Technique for Surgical Tooth Extraction

    Directory of Open Access Journals (Sweden)

    Hosamuddin Hamza

    2016-01-01

    Full Text Available Introduction. Surgical tooth extraction is a common procedure in dentistry. However, numerous extraction cases show a high level of difficulty in practice. This difficulty is usually related to inadequate visualization, improper instrumentation, or other factors related to the targeted tooth (e.g., ankyloses or presence of bony undercut. Methods. In this work, the author presents a new technique for surgical tooth extraction based on 3D imaging, computer planning, and a new concept of computer-assisted manufacturing. Results. The outcome of this work is a surgical guide made by 3D printing of plastics and CNC of metals (hybrid outcome. In addition, the conventional surgical cutting tools (surgical burs are modified with a number of stoppers adjusted to avoid any excessive drilling that could harm bone or other vital structures. Conclusion. The present outcome could provide a minimally invasive technique to overcome the routine complications facing dental surgeons in surgical extraction procedures.

  1. Comparison of serum markers for muscle damage, surgical blood loss, postoperative recovery, and surgical site pain after extreme lateral interbody fusion with percutaneous pedicle screws or traditional open posterior lumbar interbody fusion.

    Science.gov (United States)

    Ohba, Tetsuro; Ebata, Shigeto; Haro, Hirotaka

    2017-10-16

    The benefits of extreme lateral interbody fusion (XLIF) as a minimally invasive lumbar spinal fusion treatment for lumbar degenerative spondylolisthesis have been unclear. We sought to evaluate the invasiveness and tolerability of XLIF with percutaneous pedicle screws (PPS) compared with traditional open posterior lumbar interbody fusion (PLIF). Fifty-six consecutive patients underwent open PLIF and 46 consecutive patients underwent single-staged treatment with XLIF with posterior PPS fixation for degenerative lumbar spondylolisthesis, and were followed up for a minimum of 1 year. We analyzed postoperative serum makers for muscle damage and inflammation, postoperative surgical pain, and performance status. A Roland-Morris Disability Questionnaire (RDQ) and Oswestry Disability Index (ODI) were obtained at the time of hospital admission and 1 year after surgery. Intraoperative blood loss (51 ± 41 ml in the XLIF/PPS group and 206 ± 191 ml in the PLIF group), postoperative WBC counts and serum CRP levels in the XLIF/PPS group were significantly lower than in the PLIF group. Postoperative serum CK levels were significantly lower in the XLIF/PPS group on postoperative days 4 and 7. Postoperative recovery of performance was significantly greater in the XLIF/PPS group than in the PLIF group from postoperative days 2 to 7. ODI and visual analog scale (VAS) score (lumbar) 1 year after surgery were significantly lower in the XLIF/PPS group compared with the PLIF group. The XLIF/PPS procedure is advantageous to minimize blood loss and muscle damage, with consequent earlier recovery of daily activities and reduced incidence of low back pain after surgery than with the open PLIF procedure.

  2. Distally based sural neuro-fasciocutaneous perforator flap for foot and ankle reconstruction: Surgical modifications for flap pedicle and donor site closure without skin graft.

    Science.gov (United States)

    Chi, Zhenglin; Chen, Yiheng; Chu, Tinggang; Gao, Weiyang; Li, Zhijie; Yan, Hede; Song, Yonghuan

    2018-02-01

    The conventional procedure of the sural neuro-fasciocutaneous flap enables the supply of blood and venous drainage by increasing the width of the adipofascial tissue and preserving tiny venous return routes. Moreover, skin graft is a common method for donor site closure, which may lead to some complications and influence the aesthetic appearance. We report modifications for a distally based sural neuro-fasciocutaneous perforator flap and a relaying flap for donor site closure without skin graft. Twelve patients undergoing the modified flap for foot and ankle reconstruction were included in this study between 2014 and 2016. A peroneal-based perforator, a superficial vein, and the vascular axis of the sural nerve were included in the pedicle. A Z-shape skin incision was performed to explore the perforator vessels and a relaying island perforator flap was used to close the donor site. All flaps survived completely without necrosis. The area of the flaps ranged from 16 × 8 cm to 30 × 15 cm. The diameter width of the pedicle ranged from 1.0 to 2.0 cm. A relaying perforator island flap was used in 10 cases for donor site closure and no skin graft was performed. There were no serious donor site complications. All patients were satisfied with the aesthetic outcome postoperatively at the final follow-up. The distally based sural neuro-fasciocutaneous perforator flap is considered a reliable method for foot and ankle reconstruction. The modification for flap pedicle and donor site closure method without skin graft should be recommended. Copyright © 2017. Published by Elsevier Ltd.

  3. The trans-frontal-sinus subcranial approach for removal of large olfactory groove meningiomas: surgical technique and comparison to other approaches.

    Science.gov (United States)

    Boari, Nicola; Gagliardi, Filippo; Roberti, Fabio; Barzaghi, Lina Raffaella; Caputy, Anthony J; Mortini, Pietro

    2013-05-01

    Several surgical approaches have been previously reported for the treatment of olfactory groove meningiomas (OGM).The trans-frontal-sinus subcranial approach (TFSSA) for the removal of large OGMs is described, comparing it with other reported approaches in terms of advantages and drawbacks. The TFSSA was performed on cadaveric specimens to illustrate the surgical technique. The surgical steps of the TFSSA and the related anatomical pictures are reported. The approach was adopted in a clinical setting; a case illustration is reported to demonstrate the feasibility of the described approach and to provide intraoperative pictures. The TFSSA represents a possible route to treat large OGMs. The subcranial approach provides early devascularization of the tumor, direct tumor access from the base without traction on the frontal lobes, good overview of dissection of the optic nerves and anterior cerebral arteries, and dural reconstruction with pedicled pericranial flap. Georg Thieme Verlag KG Stuttgart · New York.

  4. New techniques in dental surgical CT

    International Nuclear Information System (INIS)

    Rabin, D.N.; Rabin, H.; Sakowicz, B.A.; Rabin, M.A.; Rabin, S.I.; Schwartz, A.

    1991-01-01

    This paper demonstrates how CT can be used with dental software to evaluate prosthetic failure and for planning dental implants when a stent is used. The Food and Drug Administration issued a safety alert for proplast-coated temporomandibular joint prostheses. Prosthetic failure occurs with migration, fragmentation, or bone erosion. Sagittal CT requiring a special head holder can instead be performed with reformatted sagittal images. The technique of dental implant CT changes when a dental stent is used to provide more accurate implant anchorage and planning. Images must be parallel to the occlusal plane. We will demonstrate these techniques and present their rationale

  5. The surgical correction of buried penis: a new technique

    NARCIS (Netherlands)

    Boemers, T. M.; de Jong, T. P.

    1995-01-01

    We report a new surgical technique for the correction of buried penis. The study comprised 10 boys with buried penis. The technique consisted of resection of abnormal dartos attachments, unfurling of the prepuce and correction of the deficient shaft skin by reapproximation of the preputial skin

  6. [Clinical research progress of direct surgical repair of lumbar spondylolysis in young patients].

    Science.gov (United States)

    Liu, Haichao; Qian, Jixian

    2013-01-01

    To review and summarize the surgical techniques and their outcomes for the treatment of lumbar spondylolysis in young patients by direct surgical repair. Both home and abroad literature on the surgical techniques and their outcomes respectively for the treatment of lumbar spondylolysis in young patients by direct surgical repair was reviewed extensively and summarized. Direct surgical repair of lumbar spondylolysis can offer a simple reduction and fixation for the injured vertebra, which is also in accord with normal anatomy and physiology. In this way, normal anatomy of vertebra can be sustained. As reported surgical techniques of direct repair, such as single lag screw, hook screw, cerclage wire, pedicle screw cable, pedicle screw rod, and pedicle screw hook system, they all can provide acceptable results for lumbar spondylolysis in young patients. Furthermore, to comply strictly with the inclusion criteria of surgical management and select the appropriate internal fixation can also contribute to a good effectiveness. Within the various methods of internal fixation, pedicle screw hook system has been widely recognized. Pedicle screw hook system fixation is simple and safe clinically. With the gradual improvement of this method and the development of minimally invasive technologies, it will have broad application prospects.

  7. Evolution of surgical techniques for a progressive risk reduction.

    Science.gov (United States)

    Amato, Bruno; Santoro, Mario; Izzo, Raffaele; Servillo, Giuseppe; Compagna, Rita; Di Domenico, Lorenza; Di Nardo, Veronica; Giugliano, Giuseppe

    2017-07-18

    Advanced age is a strong predictor of high perioperative mortality in surgical patients and patients aged 75 years and older have an elevated surgical risk, much higher than that of younger patients. Progressive advances in surgical techniques now make it possible to treat high-risk surgical patients with minimally invasive procedures. Endovascular techniques have revolutionized the treatment of several vascular diseases, in particular carotid stenosis, aortic pathologies, and severely incapacitating intermittent claudication or critical limb ischemia. The main advantages of the endovascular approach are the low complication rate, high rate of technical success and a good clinical outcome. Biliary stenting has improved the clinical status of severely ill patients with bile duct stricture before major surgery, and represents a good palliative therapy in the case of malignant biliary obstruction.

  8. Surgical techniques for lumbo-sacral fusion.

    Science.gov (United States)

    Tropiano, P; Giorgi, H; Faure, A; Blondel, B

    2017-02-01

    Lumbo-sacral (L5-S1) fusion is a widely performed procedure that has become the reference standard treatment for refractory low back pain. L5-S1 is a complex transition zone between the mobile lordotic distal lumbar spine and the fixed sacral region. The goal is to immobilise the lumbo-sacral junction in order to relieve pain originating from this site. Apart from achieving inter-vertebral fusion, the main challenge lies in the preoperative determination of the fixed L5-S1 position that will be optimal for the patient. Many lumbo-sacral fusion techniques are available. Stabilisation can be achieved using various methods. An anterior, posterior, or combined approach may be used. Recently developed minimally invasive techniques are gaining in popularity based on their good clinical outcomes and high fusion rates. The objective of this conference is to resolve the main issues faced by spinal surgeons in their everyday practice. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Post-traumatic arteriovenous fistula of the hepatic pedicle.

    Science.gov (United States)

    Ibn Majdoub Hassani, K; Mohsine, R; Belkouchi, A; Bensaid, Y

    2010-10-01

    Hepatico-portal fistula (HPF) is a rare condition, most often of post-traumatic or iatrogenic origin and occasionally secondary to a ruptured aneurysm of the hepatic artery into the portal vein. HPF in extrahepatic locations often results in portal hypertension (PHT). While Doppler ultrasound, CT angiography, and magnetic resonance angiography are usually demonstrative, arteriography remains indispensable to clarify the exact anatomical configuration. In the treatment of these arteriovenous (AV) fistulas, open surgical approaches have increasingly given way to radiological embolization techniques, especially in intrahepatic locations, but surgery remains indicated for AV fistulas of the hepatic pedicle where maintenance of hepatic arterial flow is a priority of treatment. We report a patient who had an AV fistula of the hepatic pedicle with resultant PHT presenting 5 years after open abdominal trauma. Treatment was surgical; the immediate and long-term postoperative course was uneventful with regression of PHT. Through analysis of this case and a review of the literature, we discuss the clinical, paraclinical, therapeutic, and prognostic features of this lesion. Copyright © 2010. Published by Elsevier Masson SAS.

  10. Use of a life-size three-dimensional-printed spine model for pedicle screw instrumentation training.

    Science.gov (United States)

    Park, Hyun Jin; Wang, Chenyu; Choi, Kyung Ho; Kim, Hyong Nyun

    2018-04-16

    Training beginners of the pedicle screw instrumentation technique in the operating room is limited because of issues related to patient safety and surgical efficiency. Three-dimensional (3D) printing enables training or simulation surgery on a real-size replica of deformed spine, which is difficult to perform in the usual cadaver or surrogate plastic models. The purpose of this study was to evaluate the educational effect of using a real-size 3D-printed spine model for training beginners of the free-hand pedicle screw instrumentation technique. We asked whether the use of a 3D spine model can improve (1) screw instrumentation accuracy and (2) length of procedure. Twenty life-size 3D-printed lumbar spine models were made from 10 volunteers (two models for each volunteer). Two novice surgeons who had no experience of free-hand pedicle screw instrumentation technique were instructed by an experienced surgeon, and each surgeon inserted 10 pedicle screws for each lumbar spine model. Computed tomography scans of the spine models were obtained to evaluate screw instrumentation accuracy. The length of time in completing the procedure was recorded. The results of the latter 10 spine models were compared with those of the former 10 models to evaluate learning effect. A total of 37/200 screws (18.5%) perforated the pedicle cortex with a mean of 1.7 mm (range, 1.2-3.3 mm). However, the latter half of the models had significantly less violation than the former half (10/100 vs. 27/100, p 3D-printed spine model can be an excellent tool for training beginners of the free-hand pedicle screw instrumentation.

  11. Treatment of unicameral bone cyst: surgical technique.

    Science.gov (United States)

    Hou, Hsien-Yang; Wu, Karl; Wang, Chen-Ti; Chang, Shun-Min; Lin, Wei-Hsin; Yang, Rong-Sen

    2011-03-01

    There is a variety of treatment modalities for unicameral bone cysts, with variable outcomes reported in the literature. Although good initial outcomes have been reported, the success rate has often changed with longer-term follow-up. We introduce a novel, minimally invasive treatment method and compare its clinical outcomes with those of other methods of treatment of this lesion. From February 1994 to April 2008, forty patients with a unicameral bone cyst were treated with one of four techniques: serial percutaneous steroid and autogenous bone-marrow injection (Group 1, nine patients); open curettage and grafting with a calcium sulfate bone substitute either without instrumentation (Group 2, twelve patients) or with internal instrumentation (Group 3, seven patients); or minimally invasive curettage, ethanol cauterization, disruption of the cystic boundary, insertion of a synthetic calcium sulfate bone-graft substitute, and placement of a cannulated screw to provide drainage (Group 4, twelve patients). Success was defined as radiographic evidence of a healed cyst or of a healed cyst with some defect according to the modified Neer classification, and failure was defined as a persistent or recurrent cyst that needed additional treatment. Patients who sustained a fracture during treatment were also considered to have had a failure. The outcome parameters included the radiographically determined healing rate, the time to solid union, and the total number of procedures needed. The follow-up time ranged from eighteen to eighty-four months. Group-4 patients had the highest radiographically determined healing rate. Healing was seen in eleven of the twelve patients in that group compared with three of the nine in Group 1, eight of the twelve in Group 2, and six of the seven in Group 3. Group-4 patients also had the shortest mean time to union: 3.7 ± 2.3 months compared with 23.4 ± 14.9, 12.2 ± 8.5, and 6.6 ± 4.3 months in Groups 1, 2, and 3, respectively. This new

  12. [Composite digital allotransplants: surgical technique and different applications].

    Science.gov (United States)

    Casoli, V; Rousvoal, A; Zirak, C; Bakhach, J; Guimberteau, J-C

    2007-10-01

    Microsurgery and human allotransplantation progress as well as the improvement of immunosuppressive drugs actually allow the development of the composite tissue allotransplantation. One of the latest challenges in plastic surgery is to restore the anatomic and functional structures using similar tissues. Composite tissue allotransplantation will probably reach this goal. Our work is to find new surgical techniques for the reconstruction of the osteotendinous apparatus of the long digits. In this paper, we will demonstrate the surgical technique to harvest the allotransplant and its modulation in the reconstruction of various digital defects.

  13. Ahmed glaucoma valve implant: surgical technique and complications

    Directory of Open Access Journals (Sweden)

    Riva I

    2017-02-01

    Full Text Available Ivano Riva,1 Gloria Roberti,1 Francesco Oddone,1 Anastasios GP Konstas,2 Luciano Quaranta3 1IRCCS “Fondazione GB Bietti per l’Oftalmologia”, Rome, Italy; 21st University Department of Ophthalmology, Glaucoma Unit, AHEPA Hospital, Thessaloniki, Greece; 3Department of Medical and Surgical Specialties, Section of Ophthalmology, University of Brescia, Brescia, Italy Abstract: Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. Keywords: glaucoma, surgical technique, glaucoma drainage devices, Ahmed glaucoma valve, complications

  14. Surgical implantation techniques for electronic tags in fish

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Glenn N.; Cooke, Steven J.; Brown, Richard S.; Deters, Katherine A.

    2011-01-01

    Intracoelomic implantation of transmitters into fish requires making a surgical incision, incision closure, and other surgery related techniques; however, the tools and techniques used in the surgical process vary widely. We review the available literature and focus on tools and techniques used for conducting surgery on juvenile salmonids because of the large amount of research that is conducted on them. The use of sterilized surgical instruments properly selected for a given size of fish will minimize tissue damage and infection rates, and speed the wound healing of fish implanted with transmitters. For the implantation of transmitters into small fish, the optimal surgical methods include making an incision on the ventral midline along the linea alba (for studies under 1 month), protecting the viscera (by lifting the skin with forceps while creating the incision), and using absorbable monofilament suture with a small-swaged-on swaged-on tapered or reverse-cutting needle. Standardizing the implantation techniques to be used in a study involving particular species and age classes of fish will improve survival and transmitter retention while allowing for comparisons to be made among studies and across multiple years. This review should be useful for researchers working on juvenile salmonids and other sizes and species of fish.

  15. Some Observations on Veterinary Undergraduate Training in Surgical Techniques.

    Science.gov (United States)

    Whittick, William G.

    1978-01-01

    The undergraduate surgery course of the Faculty of Veterinary Medicine and Animal Science, Universiti Pertanian Malaysia, is described with focus on its experential method of teaching surgical techniques. Also discussed are the benefits of veterinary school cooperation with a large city Society for the Prevention of Cruelty to Animals (SPCA). (JMD)

  16. Standardization of surgical techniques used in facial bone contouring.

    Science.gov (United States)

    Lee, Tae Sung

    2015-12-01

    Since the introduction of facial bone contouring surgery for cosmetic purposes, various surgical methods have been used to improve the aesthetics of facial contours. In general, by standardizing the surgical techniques, it is possible to decrease complication rates and achieve more predictable surgical outcomes, thereby increasing patient satisfaction. The technical strategies used by the author to standardize facial bone contouring procedures are introduced here. The author uses various pre-manufactured surgical tools and hardware for facial bone contouring. During a reduction malarplasty or genioplasty procedure, double-bladed reciprocating saws and pre-bent titanium plates customized for the zygomatic body, arch and chin are used. Various guarded oscillating saws are used for mandibular angloplasty. The use of double-bladed saws and pre-bent plates to perform reduction malarplasty reduces the chances of post-operative asymmetry or under- or overcorrection of the zygoma contours due to technical faults. Inferior alveolar nerve injury and post-operative jawline asymmetry or irregularity can be reduced by using a guarded saw during mandibular angloplasty. For genioplasty, final placement of the chin in accordance with preoperative quantitative analysis can be easily performed with pre-bent plates, and a double-bladed saw allows more procedural accuracy during osteotomies. Efforts by the surgeon to avoid unintentional faults are key to achieving satisfactory results and reducing the incidence of complications. The surgical techniques described in this study in conjunction with various in-house surgical tools and modified hardware can be used to standardize techniques to achieve aesthetically gratifying outcomes. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Innovative Surgical Management of the Synovial Chondromatosis of Temporo-Mandibular Joints: Highly Conservative Surgical Technique.

    Science.gov (United States)

    Ionna, Franco; Amantea, Massimiliano; Mastrangelo, Filiberto; Ballini, Andrea; Maglione, Maria Grazia; Aversa, Corrado; De Cecio, Rossella; Russo, Daniela; Marrelli, Massimo; Tatullo, Marco

    2016-07-01

    Synovial chondromatosis (SC) is an uncommon disease characterized by a benign nodular cartilaginous proliferation arising from the joint synovium, bursae, or tendon sheaths. Although the temporomandibular joint is rarely affected by neoplastic lesions, SC is the most common neoplastic lesion of this joint. The treatment of this disease consists in the extraoral surgery with a wide removal of the lesion; in this study, the authors described a more conservative intraoral surgical approach. Patient with SC of temporomandibular joint typically refer a limitation in the mouth opening, together with a persistent not physiological mandibular protrusion and an appearance of a neoformation located at the right preauricular region: the authors reported 1 scholar patient. After biopsy of the neoformation, confirming the synovial chondromatosis, the patient underwent thus to the surgical excision of the tumor, via authors' conservative transoral approach, to facilitate the enucleation of the neoformation. The mass fully involved the pterygo-maxillary fossa with involvement of the parotid lodge and of the right TMJ: this multifocal extension suggested for a trans-oral surgical procedure, in the light of the suspicion of a possible malignant nature of the neoplasm. Our intraoral conservative approach to surgery is aimed to reduce the presence of unaesthetic scars in preauricular and facial regions, with surgical results undoubtedly comparable to the traditional surgical techniques much more aggressive. Our technique could be a valid, alternative, and safe approach to treat this rare and complex kind of oncological disease.

  18. Nonpenetrating glaucoma surgery with goniosynechiolysis ab interno: a surgical technique.

    Science.gov (United States)

    Mirshahi, A; Scharioth, G B

    2009-01-01

    To present a surgical technique for treatment of peripheral anterior synechiae (PAS or goniosynechiae) at the operative field during nonpenetrating glaucoma surgery. After usual preparation of a superficial and a deep scleral flap with externalization of the Schlemm's canal and peeling the juxtacanalicular trabecular meshwork, the goniosynechia is transected by a spatula introduced to the anterior chamber through a paracentesis. A Descemet's window provides full visual control at the peripheral cornea at the basis of the superficial scleral flap. With this surgical technique, selective treatment of goniosynechiae is possible exactly at the area where creation of low outflow resistance is intended by the surgeon during nonpenetrating glaucoma surgery. This technique enables the surgeon to perform nonpenetrating glaucoma surgery even in the presence of peripheral anterior synechiae.

  19. Surgical techniques for treatment of gastroesophageal reflux disease

    Directory of Open Access Journals (Sweden)

    Carlos Édder de Mello Cardoso Lima

    2015-12-01

    Full Text Available Gastroesophageal reflux is one of the most frequently gastrointestinal tract diseases currently found, having a great impact on the patient's quality of life. Purpose: to analyze the main surgical techniques used in the treatment of this pathology, their indications, advantages and disadvantages. Methods: this is a literature review. Thirteen articles published between 1998 and 2013 in the Lilacs, Bireme e Scielo databases, addressing different surgical techniques for the treatment of gastroesophageal reflux were selected. Results: Five hundred and thirty-eight total fundoplications and 466 partial fundoplications were performed. Conclusion: The findings of this review show that total fundoplication is the most commonly used technique in the treatment of gastroesophageal reflux disease.

  20. Restoring accommodation: surgical technique and preliminary evaluation in rabbits

    Science.gov (United States)

    Tahi, Hassan; Chapon, Pascal F.; Hamaoui, Marie; Lee, William E.; Holden, Brien; Parel, Jean-Marie A.

    1999-06-01

    Purpose. To evaluate an innovative surgical technique for phaco-ersatz, a cataract surgery designed to restore accommodation. Techniques for very small capsulorhexis as well as the refilling procedure were developed. This study evaluates the feasibility and reproducibility of the surgical technique. Methods. The right eye of 8 NZW rabbits (~ 2 Kg) were operated following the ARVO Statements for the Use of Animals in Ophthalmic and Vision Research. The surgery is begun by making a small peripheral capsulorhexis of about 1 mm using. The lens content is then removed. The lens is then refilled with a novel in situ polymerizable gel and the corneal incision is closed using one 10/0 Nylon interrupted stitch. Results. The capsulorhexis technique was succesfully performed and reproducible in all animals. The average size of the capsulorhexis opening was 1. 2 mm (+/-0.14). Lens material removal and refilling of the capsular bag with an in situ polymerizable material was also performed in each trial study. Conclusion. This surgical technique seemed feasible and reproducible.

  1. Review of Surgical Techniques of Experimental Renal Transplantation in Rats.

    Science.gov (United States)

    Shrestha, Badri; Haylor, John

    2017-08-01

    Microvascular surgical techniques of renal transplant in rats have evolved over the past 5 decades to achieve successful rat renal transplant; these modifications have included surgical techniques to address the anatomic variations in the renal blood vessels and those to reduce ischemic and operation durations. Here, we review the surgical techniques of renal transplant in rats and evaluate the advantages and disadvantages of individual techniques of vascular and ureteric anastomoses. For this review, we performed a systematic literature search using relevant medical subject heading terms and included appropriate publications in the review. Since the first description of a rat model of renal transplant by Bernard Fisher and his colleagues in 1965, which used end-to-side anastomosis between the renal vein and renal artery to the recipient inferior vena cava and aorta, several vascular and ureteric anastomosis techniques have been modified. Vascular anastomosis techniques now include end-to-end anastomosis, use of donor aortic and inferior vena cava conduits, sleeve and cuff anastomoses, and application of fibrin glue. Likewise, restoration of the urinary tract can now be achieved by direct anastomosis of the donor ureter to the recipient bladder, end-to-end anastomosis between the donor and recipient ureters, and donor bladder cuff to the recipient bladder. There are advantages and disadvantages attributable to individual techniques. The range of vascular and ureteric anastomosis techniques that has emerged reflects the need for mastering more than one technique to suit the vascular anatomy of individual animals and to reduce operating time for achieving successful outcomes after renal transplant.

  2. [Intestinal stomas--indications, stoma types, surgical technique].

    Science.gov (United States)

    Renzulli, P; Candinas, D

    2007-09-01

    The formation of an intestinal stoma is one of the most frequent operations in visceral surgery. Despite new operative techniques and a more restrictive use of the stoma, the stoma formation remains an often necessary surgical procedure, which results to a dramatic change in the patients' life. The stoma formation and its later closure are associated with a high morbidity. Many complications, such as stoma necrosis, stoma retraction or stoma prolapse, are related to surgical mistakes made during stoma formation. These complications are therefore largely avoidable. The stoma formation needs careful planning together with a professional stoma nursing team. Moreover, it is mandatory that the stoma formation is made with great care and that it meticulously follows the well established surgical principles. A perfectly placed, technically correctly fashioned and easy to care for stoma is essential for a good patients'quality of life.

  3. Triangular lipodermal flaps in Wise pattern reduction mammoplasty (superomedial pedicle): A novel technique to reduce T-junction necrosis.

    Science.gov (United States)

    Khalil, Haitham H; Malahias, Marco; Shetty, Geeta

    2016-01-01

    Although Wise pattern reduction mammoplasty is one of the most prevalent procedures providing satisfactory cutaneous reduction, it is at the expense of inevitable lengthier scars and wound complications, especially at the inverted T junction. To describe a novel technique providing tension-free closure at the T junction through performing triangular lipodermal flaps. The aim is to alleviate skin tension, thus reducing skin necrosis, dehiscence and excessive scarring at the T junction. One hundred seventy-three consecutive procedures were performed on 137 patients between 2009 and 2013. Data collected included demographics, perioperative morbidity and resected breast tissue weight. The follow-up period ranged from three to 30 months; early and late postoperative complications and patient satisfaction were recorded. Superficial epidermolysis without T-junction dehiscence was experienced in eight (4.6%) procedures while five (2.9%) procedures developed full-thickness wound dehiscence. Ninety-four percent of patients were highly satisfied with the outcome. The technique is safe, versatile and easy to execute, providing a tension-free zone and acting as internal dermal sling, thus providing better wound healing with more favourable aesthetic outcome and maintaining breast projection.

  4. Correction Capability in the 3 Anatomic Planes of Different Pedicle Screw Designs in Scoliosis Instrumentation.

    Science.gov (United States)

    Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy

    2017-05-01

    Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of

  5. Surgical dislocation of the hip in patients with femoroacetabular impingement: Surgical techniques and our experience

    Directory of Open Access Journals (Sweden)

    Mladenović Marko

    2015-01-01

    Full Text Available Background/Aim. Arthrosis of the hip is the most common cause of a hip joint disorders. The aim of this study was to present our experience in the application of a safe surgical dislocation of the hip in patients with minor morphological changes in the hip joint, which, through the mechanism of femoroacetabular impingement, cause damage to the acetabular labrum and adjacent cartilage as an early sign of the hip arthrosis. Methods. We have operated 51 patients with different morphological bone changes in the hip area and resultant soft tissue damage of the acetabular labrum and its adjacent cartilage. Surgical technique that we applied in this group of patients, was adapted to our needs and capabilities and it was minimaly modified compared to the original procedure. Results. The surgical technique presented in this paper, proved to be a good method of treatment of bone and soft tissue pathomorphological changes of the hip in patients with femoroacetabular impingement. We had no cases with avascular necrosis of the femoral head, and two patients had nonunion of the greater trochanter, 9 patients developed paraarticular ossification, without subjective symptoms, while 3 patients suffered from postoperative pain in the groin during more energetic physical activities. Conclusion. Utilization of our partly modified surgical technique of controlled and safe dislocation of the hip can solve all the bone and soft tissue problems in patients with femoroacetibular impingement to stop already developed osteoarthritis of the hip or to prevent mild form of it.

  6. Safe surgical technique: intramedullary nail fixation of tibial shaft fractures.

    Science.gov (United States)

    Zelle, Boris A; Boni, Guilherme

    2015-01-01

    Statically locked, reamed intramedullary nailing remains the standard treatment for displaced tibial shaft fractures. Establishing an appropriate starting point is a crucial part of the surgical procedure. Recently, suprapatellar nailing in the semi-extended position has been suggested as a safe and effective surgical technique. Numerous reduction techiques are available to achieve an anatomic fracture alignment and the treating surgeon should be familiar with these maneuvers. Open reduction techniques should be considered if anatomic fracture alignment cannot be achieved by closed means. Favorable union rates above 90 % can be achieved by both reamed and unreamed intramedullary nailing. Despite favorable union rates, patients continue to have functional long-term impairments. In particular, anterior knee pain remains a common complaint following intramedullary tibial nailing. Malrotation remains a commonly reported complication after tibial nailing. The effect of postoperative tibial malalignment on the clinical and radiographic outcome requires further investigation.

  7. THD Doppler procedure for hemorrhoids: the surgical technique

    OpenAIRE

    Ratto, C.

    2013-01-01

    Transanal hemorrhoidal dearterialization (THD) is an effective treatment for hemorrhoidal disease. The ligation of hemorrhoidal arteries (called “dearterialization”) can provide a significant reduction of the arterial overflow to the hemorrhoidal piles. Plication of the redundant rectal mucosa/submucosa (called “mucopexy”) can provide a repositioning of prolapsing tissue to the anatomical site. In this paper, the surgical technique and perioperative patient management are illustrated. Followi...

  8. [Clinical efficacy of unilateral percutaneous transfacet screws combined with contralateral pedicle screw versus bilateral pedicle screws fixation in the treatment of the degenerative lumbar disease].

    Science.gov (United States)

    Hao, Rong-Xue; Zhou, Hui; Pan, Hao; Yue, Jun; Chen, Hui-Guo; Yang, He-Jie; Jia, Gao-Yong; Wang, Dong; Lin, Yan; Xu, Hua-Zi

    2017-09-25

    To investigate the surgical outcome of unilateral pedicle screw(UPS) after TLIF technique combined with contralateral percutaneous transfacet screw(PTS) fixation vs bilateral pedicle screws(BPS) fixation in treatment of degenerative lumbar disease. From January 2009 to June 2012, 46 patients with degenerative lumbar diseases, including 30 males and 16 females with an average age of 51.5 years old, who were divided into two groups according to different fixation methods. Twenty-two cases underwent UPS after TLIF technique combined with contralateral PTS fixation (group A), while the others underwent BPS fixation(group B). The relative data were analyzed, such as blood loss volume, operative time, fusion rate, ODI score, JOA score and so on. All the patients were followed up for 1 to 3 years with an average of 22 months. Except one case of each group was uncertainty fusion, the rest have obtained bony fusion, and the fusion rates in group A and B were 95.5% and 95.8%, respectively. No displacement and breakage of screw were found during follow-up. Operative time and blood loss volume in group A were better than of group B( P 0.05). Two approaches had similar clinical outcomes for degenerative lumbar disease with no severe instability. Compared with BPS fixation, the UPS after TLIF technique and contralateral PTS fixation has the advantages of less trauma, shorter operative time and less blood loss, and it is a safe and feasible surgical technique.

  9. The Kock pouch reconsidered: an alternative surgical technique.

    Science.gov (United States)

    Crawshaw, Alison; Williams, Julia; Woodhouse, Fran

    The psychological impact stoma surgery can have on an individual is well documented within the literature (White and Hunt, 1997; Borwell, 2009; Williams, 2005; Brown, 2005). For many years, surgeons have explored and developed innovations in surgical techniques, in particular restorative procedures with a view of preventing permanent stoma formation; ileal anal pouch (IAP) now being the surgical procedure of choice for treatment of ulcerative colitis (UC) and familial adenomatous polyposis (FAP). However, high morbidity rates are associated with pouch longevity (Castillo et al 2005; Nessar and Wu, 2012) and once removed can lead to a high-output ileostomy with risks of electrolyte imbalance and malabsorption. This then creates the dilemma of whether the Kock pouch (KP) should be offered as a surgical option. This article offers a historical perspective of the KP and its place in the surgical management of UC and FAP. This article also presents results from a recent audit funded by the Ileostomy Association (IA), highlighting how patients manage their KP and the importance of maintaining bowel control and being free of an incontinent stoma as a means of coming to terms with their condition.

  10. Surgical Tips in Frozen Abdomen Management: Application of Coliseum Technique.

    Science.gov (United States)

    Kyriazanos, Ioannis D; Manatakis, Dimitrios K; Stamos, Nikolaos; Stoidis, Christos

    2015-01-01

    Wound dehiscence is a serious postoperative complication, with an incidence of 0.5-3% after primary closure of a laparotomy incision, and represents an acute mechanical failure of wound healing. Relatively recently the concept of "intentional open abdomen" was described and both clinical entities share common pathophysiological and clinical pathways ("postoperative open abdominal wall"). Although early reconstruction is the target, a significant proportion of patients will develop adhesions between abdominal viscera and the anterolateral abdominal wall, a condition widely recognized as "frozen abdomen," where delayed wound closure appears as the only realistic alternative. We report our experience with a patient who presented with frozen abdomen after wound dehiscence due to surgical site infection and application of the "Coliseum technique" for its definitive surgical management. This novel technique represents an innovative alternative to abdominal exploration, for cases of "malignant" frozen abdomen due to peritoneal carcinomatosis. Lifting the edges of the surgical wound upwards and suspending them under traction by threads from a retractor positioned above the abdomen facilitates approach to the peritoneal cavity, optimizes exposure of intra-abdominal organs, and prevents operative injury to the innervation and blood supply of abdominal wall musculature, a crucial step for subsequent hernia repair.

  11. Ahmed glaucoma valve implant: surgical technique and complications.

    Science.gov (United States)

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios Gp; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.

  12. Surgical techniques and radiological findings of meniscus allograft transplantation.

    Science.gov (United States)

    Lee, Hoseok; Lee, Sang Yub; Na, Young Gon; Kim, Sung Kwan; Yi, Jae Hyuck; Lim, Jae Kwang; Lee, So Mi

    2016-08-01

    Meniscus allograft transplantation has been performed over the past 25 years to relieve knee pain and improve knee function in patients with an irreparable meniscus injury. The efficacy and safety of meniscus allograft transplantation have been established in numerous experimental and clinical researches. However, there is a lack of reviews to aid radiologists who are routinely interpreting images and evaluating the outcome of the procedures, and also meniscus allograft transplantation is not widely performed in most hospitals. This review focuses on the indications of the procedure, the different surgical techniques used for meniscus allograft transplantation according to the involvement of the lateral and medial meniscus, and the associated procedures. The postoperative radiological findings and surgical complications of the meniscus allograft transplantation are also described in detail. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Vertical-to-Horizontal Rotational Myocutaneous Flap for Repairing Cicatricial Lower Lid Ectropion: A Novel Surgical Technique

    Directory of Open Access Journals (Sweden)

    Yu-Fan Chang

    2017-01-01

    Full Text Available Objective. To evaluate the efficacy and complications of a novel surgical technique for cicatricial lower lid ectropion that uses a vertical-to-horizontal (V-to-H rotational myocutaneous flap procedure (Tsai procedure. Methods. We performed the V-to-H rotational myocutaneous flap procedure on 20 eyelids in 20 patients with mild to moderate cicatricial lower lid ectropion. A vertical myocutaneous flap was created from the anterior lamella of the vertical pedicle in the lateral third of the lower eyelid. Following a horizontal relaxing incision from the base of the flap, a vertical myocutaneous flap was created and rotated to horizontal. Two patients with combined cicatricial ectropion and paralytic lagophthalmos simultaneously underwent additional lateral tarsorrhaphy. Results. After a minimum follow-up period of 6 months, all patients showed good anatomical and functional improvement with decreased dependence on topical lubricants and a satisfactory cosmetic appearance. Two patients with combined cicatricial and paralytic ectropion had mild residual asymptomatic lagophthalmos. No patients required further revision surgery and there were no complications or recurrence. Conclusion. The V-to-H rotational myocutaneous flap technique was an effective and simple one-stage procedure for correcting cicatricial lower lid ectropion. It lengthened the anterior lamella and tightened horizontal eyelid laxity without the need for a free skin graft.

  14. ACL Surgical Technique — Staying Out of Trouble

    Directory of Open Access Journals (Sweden)

    Predescu Vlad

    2016-11-01

    Full Text Available The incidence of ACL tear and reconstruction has increased over time, and failure of ACL reconstruction is not perfectly defined among surgeons. Atraumatic failure of ACL surgery represents approximately 70% of causes, and occurs in diagnostic errors, technical errors and problems of ACL graft integrations. Regarding surgical technique, we should answer certain questions about our choice of surgery, tunnel position, graft type, graft suture, tensioning the graft, and how we deal with certain incidents or intraoperative accidents. The purpose of this article is to review the current information and trends of ACL reconstruction, and presents some tips and tricks we use in our current practice.

  15. Selection of oncoplastic surgical technique in Asian breast cancer patients

    Directory of Open Access Journals (Sweden)

    Eui Sun Shin

    2018-01-01

    Full Text Available Background Oncoplastic surgery is being increasingly performed in Korean women; however, unlike Westerners, Korean women usually have small to moderate-sized breasts. To achieve better outcomes in reconstructed breasts, several factors should be considered to determine the optimal surgical method. Methods A total of 108 patients who underwent oncoplastic surgery from January 2013 to December 2016 were retrospectively investigated. We used various methods, including glandular tissue reshaping, latissimus dorsi (LD flap transposition, and reduction oncoplasty, to restore the breast volume and symmetry. Results The mean weight of the tumor specimens was 40.46 g, and the ratio of the tumor specimen weight to breast volume was 0.12 g/mL in the patients who underwent glandular tissue reshaping (n=59. The corresponding values were 101.47 g and 0.14 g/mL, respectively, in the patients who underwent reduction oncoplasty (n=17, and 82.54 g and 0.20 g/mL, respectively, in those treated with an LD flap (n=32. Glandular tissue reshaping was mostly performed in the upper outer quadrant, and LD flap transposition was mostly performed in the lower inner quadrant. No major complications were noted. Most patients were satisfied with the aesthetic results. Conclusions We report satisfactory outcomes of oncoplastic surgical procedures in Korean patients. The results regarding specimen weight and the tumor-to-breast ratio of Asian patients will be a helpful reference point for determining the most appropriate oncoplastic surgical technique.

  16. Cervical Fusion for Absent Pedicle Syndrome Manifesting with Myelopathy.

    Science.gov (United States)

    Goodwin, C Rory; Desai, Atman; Khattab, Mohamed H; Elder, Benjamin D; Bydon, Ali; Wolinsky, Jean-Paul

    2016-02-01

    Absent congenital pedicle syndrome is a posterior arch defect characterized by numerous congenital and mechanical abnormalities that result from disconnection of the anterior and posterior columns of the spinal canal. Absent congenital pedicle syndrome is a rare anomaly that is most commonly diagnosed incidentally, after evaluation of minor trauma, or after complaints of chronic neck pain. We report a case of absent congenital pedicle syndrome in a patient who presented with myelopathy and lower extremity weakness and review the literature on the surgical management of this entity. A 32-year-old woman with a history of systemic lupus erythematosus presented to the Neurosurgery Service with progressive weakness in her upper and lower extremities, clonus, and hyperreflexia. Magnetic resonance imaging revealed congenital absence of the pedicles of C2, C3, C4, C5, and C6 with a congenitally narrow canal at C4-5. The patient underwent a staged anterior and posterior cervical decompression and fusion. She was placed in a halo after surgery; at the 1-year follow-up, she was ambulatory with demonstrated improvement in weakness and fusion of her cervical spine. Absent congenital pedicle syndrome is rare, and most reported cases were treated conservatively. Surgical management is reserved for patients with myelopathy or instability. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. A new plastic surgical technique for adult congenital webbed penis

    Science.gov (United States)

    Chen, Yue-bing; Ding, Xian-fan; Luo, Chong; Yu, Shi-cheng; Yu, Yan-lan; Chen, Bi-de; Zhang, Zhi-gen; Li, Gong-hui

    2012-01-01

    Objective: To introduce a novel surgical technique for correction of adult congenital webbed penis. Methods: From March 2010 to December 2011, 12 patients (age range: 14–23 years old) were diagnosed as having a webbed penis and underwent a new surgical procedure designed by us. Results: All cases were treated successfully without severe complication. The operation time ranged from 20 min to 1 h. The average bleeding volume was less than 50 ml. All patients achieved satisfactory cosmetic results after surgery. The penile curvature disappeared in all cases and all patients remained well after 1 to 3 months of follow-up. Conclusions: Adult webbed penis with complaints of discomfort or psychological pressure due to a poor profile should be indicators for surgery. Good corrective surgery should expose the glans and coronal sulcus, match the penile skin length to the penile shaft length dorsally and ventrally, and provide a normal penoscrotal junction. Our new technique is a safe and effective method for the correction of adult webbed penis, which produces satisfactory results. PMID:22949367

  18. Congenitally absent thoracic pedicle in a child with rhabdomyosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Kaufman, R A; Poznanski, A K; Hensinger, R N

    1980-04-01

    A case of congenital absence of a thoracic pedicle is reported in a 9 year old boy with embryonal rhabdomyosarcoma of the eyelid. In this clinical setting a surgical exploration was necessary in order to differentiate a developmental anomaly from an acquired metastatic deposit.

  19. Accuracy of pedicle screw placement in patients with Marfan syndrome.

    Science.gov (United States)

    Qiao, Jun; Zhu, Feng; Xu, Leilei; Liu, Zhen; Sun, Xu; Qian, Bangping; Jiang, Qing; Zhu, Zezhang; Qiu, Yong

    2017-03-21

    There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior and categorized to four grades: ≤ 2 mm as Grade 1, 2.1-4.0 mm as Grade 2, 4.1-6.0 mm as Grade 3, ≥6.1 mm as Grade 4. Fully contained screws or with medial wall perforation ≤ 2 mm or with lateral wall perforation ≤ 6 mm and without injury of visceral organs were considered acceptable, otherwise were unacceptable. 976 pedicle screws were placed, 713 screws (73.1%) were fully contained within the cortical boundaries of the pedicle. 924 (94.7%) screws were considered as acceptable, and 52 (5.3%) as unacceptable. The perforation rate was higher using free-hand technique than O-arm navigation technique (30.8% VS. 11.4%, P Marfan syndrome is accuracy and safe. O-arm navigation was an effective modality to ensure the safety and accuracy of screw placement. Special attention should be paid when screws were placed at the lumber spine and the concave side of spine deformity to avoid the higher rate of complications.

  20. Decision making in double-pedicled DIEP and SIEA abdominal free flap breast reconstructions: An algorithmic approach and comprehensive classification.

    Directory of Open Access Journals (Sweden)

    Charles M Malata

    2015-10-01

    Full Text Available Introduction: The deep inferior epigastric artery perforator (DIEP free flap is the gold standard for autologous breast reconstruction. However, using a single vascular pedicle may not yield sufficient tissue in patients with midline scars or insufficient lower abdominal pannus. Double-pedicled free flaps overcome this problem using different vascular arrangements to harvest the entire lower abdominal flap. The literature is, however, sparse regarding technique selection. We therefore reviewed our experience in order to formulate an algorithm and comprehensive classification for this purpose. Methods: All patients undergoing unilateral double-pedicled abdominal perforator free flap breast reconstruction (AFFBR by a single surgeon (CMM over 40 months were reviewed from a prospectively collected database. Results: Of the 112 consecutive breast free flaps performed, 25 (22% utilised two vascular pedicles. The mean patient age was 45 years (range=27-54. All flaps but one (which used the thoracodorsal system were anastomosed to the internal mammary vessels using the rib-preservation technique. The surgical duration was 656 minutes (range=468-690 mins. The median flap weight was 618g (range=432-1275g and the mastectomy weight was 445g (range=220-896g. All flaps were successful and only three patients requested minor liposuction to reduce and reshape their reconstructed breasts.Conclusion: Bipedicled free abdominal perforator flaps, employed in a fifth of all our AFFBRs, are a reliable and safe option for unilateral breast reconstruction. They, however, necessitate clear indications to justify the additional technical complexity and surgical duration. Our algorithm and comprehensive classification facilitate technique selection for the anastomotic permutations and successful execution of these operations.

  1. [Surgical closure of patent ductus arteriosus in premature neonates: Does the surgical technique affect the outcome?

    Science.gov (United States)

    Avila-Alvarez, Alejandro; Serantes Lourido, Marta; Barriga Bujan, Rebeca; Blanco Rodriguez, Carolina; Portela-Torron, Francisco; Bautista-Hernandez, Victor

    2017-05-01

    Surgical closure of patent ductus arteriosus in premature neonates is an aggressive technique and is not free of complications. A study was designed with the aim of describing our experience with a less invasive technique, the extra-pleural approach via a posterior minithoracotomy, and to compare the results with the classic transpleural approach. A retrospective cohort study was conducted on premature neonates on whom surgical closure of the ductus was performed during a ten-year period (March 2005 to March 2015). A comparison was made of the acute complications, the outcomes on discharge, and follow-up, between the extra-pleural approach and the classic transpleural approach. The study included 48 patients, 30 in the classical approach and 18 in the extra-pleural group. The demographic and pre-operative characteristics were similar in both groups. No differences were found between the 2 groups in the incidence of acute post-operative complications (56.6 vs. 44.4%), on the dependence on oxygen at 36 weeks (33.3 vs. 55.5%), or in hospital mortality (10 vs. 16.6%). As regards the short-term progress, the extra-pleural group required fewer days until the withdrawal of supplementary oxygen (36.3 vs. 28.9) and until hospital discharge (67.5 vs. 53.2), although only the time until extubation achieved a statistically significant difference (11.5 vs. 2.7, P=.03). The extra-plural approach by posterior minithoracotomy for the surgical closure of ductus in the premature infant is viable and could bring some clinical benefits in the short-term. Copyright © 2015 Asociación Española de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. History of Retractor Technologies for Percutaneous Pedicle Screw Fixation Systems.

    Science.gov (United States)

    Mobbs, Ralph J; Phan, Kevin

    2016-02-01

    Minimally invasive techniques aimed at minimizing surgery-associated risk and morbidity of spinal surgery have increased in popularity in recent years. Their potential advantages include reduced length of hospital stay, blood loss, and requirement for post-operative analgesia and earlier return to work. One such minimally invasive technique is the use of percutaneous pedicle screw fixation, which is paramount for promoting rigid and stable constructs and fusion in the context of trauma, tumors, deformity and degenerative disease. Percutaneous pedicle screw insertion can be an intimidating prospect for surgeons who have only been trained in open techniques. One of the ongoing challenges of this percutaneous system is to provide the surgeon with adequate access to the pedicle entry anatomy and adequate tactile or visual feedback concerning the position and anatomy of the rod and set-screw construct. This review article discusses the history and evolution of percutaneous pedicle screw retractor technologies and outlines the advances over the last decade in the rapidly expanding field of minimal access surgery for posterior pedicle screw based spinal stabilization. As indications for percutaneous pedicle screw techniques expand, the nuances of the minimally invasive surgery techniques and associated technologies will also multiply. It is important that experienced surgeons have access to tools that can improve access with a greater degree of ease, simplicity and safety. We here discuss the technical challenges of percutaneous pedicle screw retractor technologies and a variety of systems with a focus on the pros and cons of various retractor systems. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  3. THD Doppler procedure for hemorrhoids: the surgical technique.

    Science.gov (United States)

    Ratto, C

    2014-03-01

    Transanal hemorrhoidal dearterialization (THD) is an effective treatment for hemorrhoidal disease. The ligation of hemorrhoidal arteries (called "dearterialization") can provide a significant reduction of the arterial overflow to the hemorrhoidal piles. Plication of the redundant rectal mucosa/submucosa (called "mucopexy") can provide a repositioning of prolapsing tissue to the anatomical site. In this paper, the surgical technique and perioperative patient management are illustrated. Following adequate clinical assessment, patients undergo THD under general or spinal anesthesia, in either the lithotomy or the prone position. In all patients, distal Doppler-guided dearterialization is performed, providing the selective ligation of hemorrhoidal arteries identified by Doppler. In patients with hemorrhoidal/muco-hemorrhoidal prolapse, the mucopexy is performed with a continuous suture including the redundant and prolapsing mucosa and submucosa. The description of the surgical procedure is complemented by an accompanying video (see supplementary material). In long-term follow-up, there is resolution of symptoms in the vast majority of patients. The most common complication is transient tenesmus, which sometimes can result in rectal discomfort or pain. Rectal bleeding occurs in a very limited number of patients. Neither fecal incontinence nor chronic pain should occur. Anorectal physiology parameters should be unaltered, and anal sphincters should not be injured by following this procedure. When accurately performed and for the correct indications, THD is a safe procedure and one of the most effective treatments for hemorrhoidal disease.

  4. [Minimally invasive surgical therapy of gynecomastia: liposuction and exeresis technique].

    Science.gov (United States)

    Voigt, M; Walgenbach, K J; Andree, C; Bannasch, H; Looden, Z; Stark, G B

    2001-10-01

    A number of techniques are available for the correction of gynecomastia. Nonscarring sparing methods are preferred, and the minimally invasive technique is to use liposuction for the gland and the fatty tissue exclusively. In this retrospective study we present our experience with a combination of liposuction and subsequent resection of the remaining gland. Sixty-two patients (112 breasts) were surgically treated for gynecomastia from January 1996 and September 2000. From 1996 to 1997 all patients suffering from gynecomastia grade Simon I-II were treated by the method described by Rosenberg and Stark, which is exclusively suction of the fatty and glandular tissue. In a retrospective chart study a high recurrence rate was found in these patients. Subsequently we changed our technique to liposuction of the fatty tissue followed by sharp excision of the glandular tissue through the incision made for the liposuction cannula in the submammary fold. Suction alone was not sufficient to remove the glandular tissue; the rate of recurrence after suction was 35%. When sharp resection of the glandular tissue was carried out after the liposuction the recurrence rate dropped to under 10%. In total our complication rate was 50% including minor sequelae. The most frequent complication was unacceptable scarring of the nipple-areola complex. Hypesthesia of the nipple-areola occurred in 13.4% of the patients. The combination of liposuction and resection of the glandular tissue is a minimally invasive correction that can be used in all cases of gynecomastia grade Simon I-II.

  5. Surgical techniques for the atomic bomb survivors of thyroid cancer

    International Nuclear Information System (INIS)

    Takeichi, Nobuo; Dohi, Kiyohiko; Noso, Yoshihiro

    2016-01-01

    As for proper surgical techniques for radiation-induced thyroid carcinogenesis, this paper explains with a focus on the Hiroshima University cases, with an addition of the cases of Radiation Effects Research Foundation and Takeichi Clinic. The definitive diagnosis of thyroid cancer is usually carried out by echo-guided aspiration biopsy cytology, but Takeichi Clinic faces the surgery by preparing 'thyroid - cervical lymph node map' by combining this technique with CT and MRI. As the surgery examples at Hiroshima University, 259 cases during 1955-1972 and 363 cases during 1965-1982 were taken up, and the survival rate and cancer death rate classified by tissue types for 10 years after the initial operations were shown in a table. Dead patients were mostly the surgery cases of senior persons of 60 years in age or older, and the death rate for surgery cases of the persons of 19 years old or younger was only 1.9% at 6 cases. Higher cancer death rate was seen in the cases of papillary cancer of more than 5 cm in size, where extra glandular infiltration could not be curated or cut out, and 64/318 cases of patients had a recurrence of cancer at thyroid gland. The mortality rate up to 20 years after the surgery of atomic bomb survivors was not significantly different from that of non-victims. Information on the multicentric cancerous focuses and microscopic cancer in the thyroid gland, as well as the tissue types and high risk of cancer death were described from the cases of Hiroshima University and Takeichi Clinic. The thyroid cancer of radiation exposure victims often results in papillary cancer, and the following are described related with this: (1) selection of ablation method, (2) method to protect the parathyroid tissue, and (3) method to prevent damage to the recurrent laryngeal nerve and superior laryngeal nerve. The surgical procedure to perform the neck outside area lymph node dissection due to the quasi-subtotal or quasi-complete removal of the thyroid gland is

  6. [Endoscopic calcaneoplasty (ECP) in Haglund's syndrome. Indication, surgical technique, surgical findings and results].

    Science.gov (United States)

    Jerosch, J; Sokkar, S; Dücker, M; Donner, A

    2012-06-01

    Posterior calcaneal exostosis treatment modalities have given rise to many controversial opinions. After failure of the conservative treatment, surgical bursectomy and resection of the calcaneal exostosis are indicated by many authors. But clinical studies also show a high rate of unsatisfactory results with a relative high incidence of complications. The minimally invasive surgical technique by an endoscopic calcaneoplasty (ECP) could be an option to overcome some of these problems. Between 1999 und 2010 we operated 164 patients with an age range between 16 and 67 years, 81 males and 83 females. The radiological examination prior to surgery documented in all cases a posterior superior calcaneal exostosis that showed friction to the Achilles tendon. All patients included in the study had no clinical varus of the hind foot, nor cavus deformities. All patients had undergone a trial of conservative treatment for at least 6 months and did not show a positive response. The average follow-up was 46.3 (range: 8-120) months. According to the Ogilvie-Harris score 71 patients presented good and 84 patients excellent results, while 5 patients showed fair results, and 4 patients only poor results. All the post-operative radiographs showed sufficient resection of the calcaneal spur. In 61 patients the preoperative MRI showed a partial rupture of the Achilles tendon close to the insertion side. In no case could we observe a complete tear at the time of follow-up. Only minor postoperative complications were observed. In many patients we could observe a chondral layer at the posterior aspect of the calcaneus. Close to the intersion the Achilles tendon showed also in many patients a chondroide metaplasia. ECP is an effective and minimally invasive procedure for the treatment of patients with calcaneal exostosis. After a short learning curve the endoscopic exposure is superior to the open technique, has less morbidity, less operating time, and nearly no complications. Moreover, the

  7. Accuracy of navigated pedicle screw insertion by a junior spine surgeon without spinal surgery experience

    International Nuclear Information System (INIS)

    Yamazaki, Hironori; Kotani, Toshiaki; Motegi, Hiroyuki; Nemoto, Tetsuharu; Koshi, Takana; Nagahara, Ken; Minami, Syohei

    2010-01-01

    The purpose of this study was to investigate pedicle screw placement accuracy during navigated surgery by a junior spine surgeon who had no spinal surgery experience. A junior spine surgeon with no spinal surgery experience implanted a total of 137 pedicle screws by using a navigation system. Postoperative computerized tomography was performed to evaluate screw placement, and the pedicle perforation rate was 2.2%. There were no neurologic or vascular complications related to the pedicle screws. The results demonstrated that pedicle screws can be placed safely and effectively by a junior spine surgeon who has no spinal surgery experience when instructed by a senior spine surgeon. The results of this study suggest that navigation can be used as a surgical training tool for junior spine surgeons. (author)

  8. Nilai Rerata Vascular Pedicle Width, Vascular Pedicle-Cardiac Ratio Vascular Pedicle-Thoracic Ratio Orang Dewasa Normal Indonesia Studi di RS dr. Cipto Mangunkusomo

    Directory of Open Access Journals (Sweden)

    Rommy Zunera

    2016-03-01

    Full Text Available Vascular pedicle width (VPW adalah jarak tepi luar vena kava superior ke tepi luar arteri subklavia kiri. Pemeriksaan VPW di foto toraks bersifat non-invasif, cepat dan mudah untuk memprediksi hipervolemia.Penelitian ini bertujuan untuk mengetahui rerata nilai VPW orang dewasa normal Indonesia. VPW diukurdengan dua metode: pertama pengukuran VPW tunggal yang akurasinya terbatas di foto toraks digital karenarelatif tidak dipengaruhi faktor magnifikasi. Metode kedua untuk foto toraks nondigital yaitu pengukuranrasio:vascular pedicle-cardiac ratio (VPCR dan vascular pedicle-thoracic ratio (VPTR. Pengukuran serupadilakukan terhadap  topogram CT scan toraks AP terlentang dan CT scan toraks lalu dibandingkan akurasipengukuran di topogram dengan CT scan  toraks sebagai standar baku. Sampel terdiri atas 104 foto toraksPA subyek normal dan 103 CT scan  toraks subyek terpilih. Pada pemeriksaan toraks PA didapatkan rerata VPW 48,0±5,5mm, rerata VPCR 40,3±4,6%, dan rerata VPTR 17,2±1,7%. Pada pemeriksaan topogram CTscan didapatkan rerata VPW 50,3±6,2mm, rerata VPTR 45±5,1%, dan rerata VPTR 19,8±2,5%. Rerata VPWpada CT scan toraks 50,4±6,1mm. Pengukuran di foto toraks AP 10% lebih besar dibandingkan pada fototoraks PA dan pengukuranVPW di foto toraks terbukti memiliki akurasi  tinggi. Kata kunci: fototoraks, vascular pedicle width, vascular pedicle-cardiac ratio, vascular pedicle-thoracic ratio, hipervolemia.   The Mean Value of Vascular Pedicle Width, Vascular Pedicle-Cardiac Ratio,Vascular Pedicle-Thoracic Ratio of Normal Indonesian Adult Study In dr. Cipto Mangunkusomo Hospital Abstract Vascular pedicle width (VPW is the distance, from a perpendicular line at the takeoff point of the left subclavian artery off the aorta to the point at which the superior vena cava. Measurement of VPW on chestx-ray is relatively non-invasive, fast and easy technique as  hypervolemia predictor. The purpose of thisstudy is to know the mean VPW value of normal

  9. Through Knee Amputation: Technique Modifications and Surgical Outcomes

    Directory of Open Access Journals (Sweden)

    Frank P Albino

    2014-09-01

    Full Text Available BackgroundKnee disarticulations (KD are most commonly employed following trauma or tumor resection but represent less than 2% of all lower extremity amputations performed in the United States annually. KDs provide enhanced proprioception, a long lever arm, preservation of adductor muscle insertion, decreased metabolic cost of ambulation, and an end weight-bearing stump. The role for KDs in the setting of arterial insufficiency or overwhelming infection is less clear. The purpose of this study is to describe technique modifications and report surgical outcomes following KDs at a high-volume Limb Salvage Center.MethodsA retrospective study of medical records for all patients who underwent a through-knee amputation performed by the senior author (C.E.A. between 2004 and 2012 was completed. Medical records were reviewed to collect demographic, operative, and postoperative information for each of the patients identified.ResultsBetween 2004 and 2012, 46 through-knee amputations for 41 patients were performed. The mean patient age was 68 and indications for surgery included infection (56%, arterial thrombosis (35%, and trauma (9%. Postoperative complications included superficial cellulitis (13%, soft tissue infection (4%, and flap ischemia (4% necessitating one case of surgical debridement (4% and four trans-femoral amputations (9%. 9 (22% patients went on to ambulate. Postoperative ambulation was greatest in the traumatic cohort and for patients less than 50 years of age, P<0.05. Alternatively, diabetes mellitus and infection reduced the likelihood of postoperative ambulation, P<0.01.ConclusionsKnee disarticulations are a safe and effective alternative to other lower extremity amputations when clinically feasible. For patient unlikely to ambulate, a through-knee amputation maximizes ease of transfers, promotes mobility by providing a counterbalance, and eliminates the potential for knee flexion contracture with subsequent skin breakdown.

  10. The freestyle pedicle perforator flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Jackson, Ian T; Westvik, Tormod S

    2015-01-01

    BACKGROUND: Perforating vessels are a consistent anatomical finding and well described in the current literature. Any skin flap can be raised on a subcutaneous pedicle as long as it contains at least one supplying perforator. Perforator flaps have been interlinked with microsurgery and generally...... not widely performed by the general plastic surgeons. The aim of this paper is to present the simplicity of pedicled perforator flap reconstruction of moderate-sized defects of the extremities and torso. METHODS: We retrospectively reviewed the charts of 34 patients reconstructed using 34 freestyle pedicled...... perforator flaps for moderate-sized defects of the truncus and extremities. We registered indications, flap size and localization, success rate, and complications. Most importantly, we describe a simple approach to the design of freestyle pedicled perforator flaps and elaborate on technical aspects...

  11. A case of incisional hernia repair using Composix mesh prosthesis after antethoracic pedicled jejunal flap reconstruction following an esophagectomy.

    Science.gov (United States)

    Yasuda, Atsushi; Yasuda, Takushi; Kato, Hiroaki; Iwama, Mitsuru; Shiraishi, Osamu; Hiraki, Yoko; Tanaka, Yumiko; Shinkai, Masayuki; Imano, Motohiro; Kimura, Yutaka; Imamoto, Haruhiko

    2017-12-01

    An incisional hernia in a case of antethoracic pedicled jejunal flap esophageal reconstruction after esophagectomy is a very rare occurrence, and this hernia was distinctive in that the reconstructed jejunum had passed through the hernial orifice; a standard surgical treatment for such a presentation has not been established. Herein, we describe a case of repair using mesh prosthesis for an atypical and distinctive incisional hernia after antethoracic pedicled jejunal flap esophageal reconstruction. A 77-year-old woman with a history of subtotal esophagectomy who had undergone antethoracic pedicled jejunal flap reconstruction complained of epigastric prominence and discomfort without pain. On examination, she had an abdominal protrusion between the xiphoid process and the umbilicus that contained the small bowel. Computed tomography showed that the fenestration of the abdominal wall that was intentionally created for jejunum pull-up was dehisced in a region measuring 9 × 15 cm and the small intestine protruded through it into the subcutaneous space without strangulation. Because the hernial orifice was too large and the reconstructed jejunum was passing through the hernial orifice in this case, we applied a parastomal hernia repair method that was modified from the inguinal hernia repair using the Lichtenstein technique. After 3 years and 5 months following surgery, the patient has recovered without hernia recurrence or other complications. We consider this to be the first case of repair using Composix mesh prosthesis for repair of an atypical and distinctive incisional hernia after an antethoracic pedicled jejunal flap reconstruction. This method seems to be useful and could potentially be widely adopted as the surgical treatment for this condition.

  12. Surgical treatment of gynecomastia: mastectomy compared to liposuction technique.

    Science.gov (United States)

    Song, Yan-Ni; Wang, Yan-Bo; Huang, Rui; He, Xiao-Guang; Zhang, Jin-Feng; Zhang, Guo-Qiang; Ren, Yan-Lv; Pang, Jian-Hua; Pang, Da

    2014-09-01

    Gynecomastia is a benign enlargement of the male breast. Yet enlarged breasts cause anxiety, embarrassment, psychosocial discomfort, and fear of breast cancer. The aim of this study was to assess the experience of gynecomastia patients undergoing mastectomy and liposuction surgery. Seven hundred thirty-three patients were analyzed for age, chief complaint, position, grade, operation approach, biopsy, and complication between mastectomy group and liposuction group, from 1990 to 2010. Four hundred two patients (436 breasts) were treated with mastectomy and 331 patients (386 breasts) were treated with liposuction techniques. Three hundred thirty (82%) patients complained of breast lump and lump with pain in mastectomy group, and 204 (61%) patients complained of enlargement breast and enlargement with pain in liposuction group (P liposuction acquired pathologic diagnosis through fine needle aspiration and/or core biopsy (P liposuction group were 1.4% and 0.5%, respectively. There were no nipple/areola necrosis and scars in liposuction group. The surgical treatment of gynecomastia required an individual approach, depending on symptoms (lump or enlargement) and requirements of patients. Patients who chose mastectomy were looking for reassurance that their pathologic diagnosis was benign. The increase in the number of liposuction patients was reflected in our study because it was associated with superior esthetic results and few complications.

  13. The axillary approach to raising the latissimus dorsi free flap for facial re-animation: a descriptive surgical technique.

    Science.gov (United States)

    Leckenby, Jonathan; Butler, Daniel; Grobbelaar, Adriaan

    2015-01-01

    The latissimus dorsi flap is popular due to the versatile nature of its applications. When used as a pedicled flap it provides a robust solution when soft tissue coverage is required following breast, thoracic and head and neck surgery. Its utilization as a free flap is extensive due to the muscle's size, constant anatomy, large caliber of the pedicle and the fact it can be used for functional muscle transfers. In facial palsy it provides the surgeon with a long neurovascular pedicle that is invaluable in situations where commonly used facial vessels are not available, in congenital cases or where previous free functional muscle transfers have been attempted, or patients where a one-stage procedure is indicated and a long nerve is required to reach the contra-lateral side. Although some facial palsy surgeons use the trans-axillary approach, an operative guide of raising the flap by this method has not been provided. A clear guide of raising the flap with the patient in the supine position is described in detail and offers the benefits of reducing the risk of potential brachial plexus injury and allows two surgical teams to work synchronously to reduce operative time.

  14. Robotic partial nephrectomy for complex renal tumors: surgical technique.

    Science.gov (United States)

    Rogers, Craig G; Singh, Amar; Blatt, Adam M; Linehan, W Marston; Pinto, Peter A

    2008-03-01

    Laparoscopic partial nephrectomy requires advanced training to accomplish tumor resection and renal reconstruction while minimizing warm ischemia times. Complex renal tumors add an additional challenge to a minimally invasive approach to nephron-sparing surgery. We describe our technique, illustrated with video, of robotic partial nephrectomy for complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance was used to resect 14 tumors in eight patients (mean age: 50.3 yr; range: 30-68 yr). Three patients had hereditary kidney cancer. All patients had complex tumor features, including hilar tumors (n=5), endophytic tumors (n=4), and/or multiple tumors (n=3). Robotic partial nephrectomy procedures were performed successfully without complications. Hilar clamping was used with a mean warm ischemia time of 31 min (range: 24-45 min). Mean blood loss was 230 ml (range: 100-450 ml). Histopathology confirmed clear-cell renal cell carcinoma (n=3), hybrid oncocytic tumor (n=2), chromophobe renal cell carcinoma (n=2), and oncocytoma (n=1). All patients had negative surgical margins. Mean index tumor size was 3.6 cm (range: 2.6-6.4 cm). Mean hospital stay was 2.6 d. At 3-mo follow-up, no patients experienced a statistically significant change in serum creatinine or estimated glomerular filtration rate and there was no evidence of tumor recurrence. Robotic partial nephrectomy is safe and feasible for select patients with complex renal tumors, including hilar, endophytic, and multiple tumors. Robotic assistance may facilitate a minimally invasive, nephron-sparing approach for select patients with complex renal tumors who might otherwise require open surgery or total nephrectomy.

  15. Lengthening of fourth brachymetatarsia by three different surgical techniques.

    Science.gov (United States)

    Lee, W-C; Yoo, J H; Moon, J-S

    2009-11-01

    We carried out a retrospective study to assess the clinical results of lengthening the fourth metatarsal in brachymetatarsia in 153 feet of 106 patients (100 female, six males) using three different surgical techniques. In one group lengthening was performed by one-stage intercalary bone grafting secured by an intramedullary Kirschner-wire (45 feet, 35 patients). In the second group lengthening was obtained gradually using a mini-external fixator after performing an osteotomy with a saw (59 feet, 39 patients) and in the third group lengthening was achieved in a gradual manner using a mini-external fixator after undertaking an osteotomy using osteotome through pre-drilled holes (49 feet, 32 patients). The mean age of the patients was 26.3 years (13 to 48). Pre-operatively, the fourth ray of the bone-graft group was longer than that of other two groups (p lengthening in the bone-graft group was 13.9 mm (3.5 to 23.0, 27.1%) which was less than that obtained in the saw group with a mean of 17.8 mm (7.0 to 33.0, 29.9%) and in the pre-drilled osteotome group with a mean of 16.8 mm (6.5 to 28.0, 29.4%, p = 0.001). However, the mean time required for retention of the fixation in the bone-graft group was the shortest of the three groups. Patients were dissatisfied with the result for five feet (11.1%) in the bone-graft group, eight (13.6%) in the saw group and none in the pre-drilled osteotomy group (p lengthening by distraction osteogenesis after osteotomy using an osteotome produces the most reliable results for the treatment of fourth brachymetatarsia.

  16. Minimal access direct spondylolysis repair using a pedicle screw-rod system: a case series

    Directory of Open Access Journals (Sweden)

    Mohi Eldin Mohamed

    2012-11-01

    Full Text Available Abstract Introduction Symptomatic spondylolysis is always challenging to treat because the pars defect causing the instability needs to be stabilized while segmental fusion needs to be avoided. Direct repair of the pars defect is ideal in cases of spondylolysis in which posterior decompression is not necessary. We report clinical results using segmental pedicle-screw-rod fixation with bone grafting in patients with symptomatic spondylolysis, a modification of a technique first reported by Tokuhashi and Matsuzaki in 1996. We also describe the surgical technique, assess the fusion and analyze the outcomes of patients. Case presentation At Cairo University Hospital, eight out of twelve Egyptian patients’ acute pars fractures healed after conservative management. Of those, two young male patients underwent an operative procedure for chronic low back pain secondary to pars defect. Case one was a 25-year-old Egyptian man who presented with a one-year history of axial low back pain, not radiating to the lower limbs, after falling from height. Case two was a 29-year-old Egyptian man who presented with a one-year history of axial low back pain and a one-year history of mild claudication and infrequent radiation to the leg, never below the knee. Utilizing a standardized mini-access fluoroscopically-guided surgical protocol, fixation was established with two titanium pedicle screws place into both pedicles, at the same level as the pars defect, without violating the facet joint. The cleaned pars defect was grafted; a curved titanium rod was then passed under the base of the spinous process of the affected vertebra, bridging the loose fragment, and attached to the pedicle screw heads, to uplift the spinal process, followed by compression of the defect. The patients were discharged three days after the procedure, with successful fusion at one-year follow-up. No rod breakage or implant-related complications were reported. Conclusions Where there is no

  17. Lateral Interbody Fusion for Treatment of Discogenic Low Back Pain: Minimally Invasive Surgical Techniques

    Directory of Open Access Journals (Sweden)

    Luis Marchi

    2012-01-01

    Full Text Available Low back pain is one of the most common ailments in the general population, which tends to increase in severity along with aging. While few patients have severe enough symptoms or underlying pathology to warrant surgical intervention, in those select cases treatment choices remain controversial and reimbursement is a substancial barrier to surgery. The object of this study was to examine outcomes of discogenic back pain without radiculopathy following minimally-invasive lateral interbody fusion. Twenty-two patients were treated at either one or two levels (28 total between L2 and 5. Discectomy and interbody fusion were performed using a minimallyinvasive retroperitoneal lateral transpsoas approach. Clinical and radiographic parameters were analyzed at standard pre- and postoperative intervals up to 24 months. Mean surgical duration was 72.1 minutes. Three patients underwent supplemental percutaneous pedicle screw instrumentation. Four (14.3% stand-alone levels experienced cage subsidence. Pain (VAS and disability (ODI improved markedly postoperatively and were maintained through 24 months. Segmental lordosis increased significantly and fusion was achieved in 93% of levels. In this series, isolated axial low back pain arising from degenerative disc disease was treated with minimally-invasive lateral interbody fusion in significant radiographic and clinical improvements, which were maintained through 24 months.

  18. The pedicle screw-rod system is an acceptable method of reconstructive surgery after resection of sacroiliac joint tumours

    Directory of Open Access Journals (Sweden)

    Yi-Jun Zhou

    2016-03-01

    Full Text Available Hemipelvic resections for primary bone tumours require reconstruction to restore weight bearing along anatomic axes. However, reconstruction of the pelvic arch remains a major surgical challenge because of the high rate of associated complications. We used the pedicle screw-rod system to reconstruct the pelvis, and the purpose of this investigation was to assess the oncology, functional outcome and complication rate following this procedure. The purpose of this study was to investigate the operative indications and technique of the pedicle screw-rod system in reconstruction of the stability of the sacroiliac joint after resection of sacroiliac joint tumours. The average MSTS (Musculoskeletal Tumour Society score was 26.5 at either three months after surgery or at the latest follow-up. Seven patients had surgery-related complications, including wound dehiscence in one, infection in two, local necrosis in four (including infection in two, sciatic nerve palsy in one and pubic symphysis subluxation in one. There was no screw loosening or deep vein thrombosis occurring in this series. Using a pedicle screw-rod after resection of a sacroiliac joint tumour is an acceptable method of pelvic reconstruction because of its reduced risk of complications and satisfactory functional outcome, as well as its feasibility of reconstruction for type IV pelvis tumour resection without elaborate preoperative customisation. Level of evidence: Level IV, therapeutic study.

  19. Surgical Approaches to Chronic Pancreatitis: Indications and Techniques.

    Science.gov (United States)

    Dua, Monica M; Visser, Brendan C

    2017-07-01

    There are a number of surgical strategies for the treatment of chronic pancreatitis. The optimal intervention should provide effective pain relief, improve/maintain quality of life, preserve exocrine and endocrine function, and manage local complications. Pancreaticoduodenectomy was once the standard operation for patients with chronic pancreatitis; however, other procedures such as the duodenum-preserving pancreatic head resections and its variants have been introduced with good long-term results. Pancreatic duct drainage via a lateral pancreaticojejunostomy continues to be effective in ameliorating symptoms and expediting return to normal lifestyle in many patients. This review summarizes operative indications and gives an overview of the different surgical strategies in treating chronic pancreatitis.

  20. reduction mammoplasty using inferior pedicle in heavy breasts

    African Journals Online (AJOL)

    2011-09-09

    Sep 9, 2011 ... sexual relationships. Reduction mammoplasty procedure provides weight and volume reduction of the breast as well as enhancement of the aesthetic appearance of the breasts. In this study, the inferior pedicle technique was used in reduction of thirty five patients over the last four years with macromastia.

  1. Fournier?s gangrene - delayed pedicle flap based upon the anterior abdominal wall

    Directory of Open Access Journals (Sweden)

    Ania Sliwinski

    2014-06-01

    Full Text Available Introduction Fournier’s gangrene is a poly-microbial necrotizing fasciitis that involves the perineum and/or external genitalia. Urgent surgical debridement is well recognized as essential acute treatment yet unique challenges arise for plastic surgical reconstruction to obtain a complete functional recovery. This case describes a successful delayed pedicle flap repair based upon the anterior abdominal wall. Case description A 24 year old man was admitted to ICU ten days after elective circumcision with Fournier’s gangrene. He underwent a number of surgical debridements, and was referred for plastic surgical management. He had penile reconstruction using a random pattern abdominal flap, which was performed as a three stage procedure including flap vascular delay technique. Discussion Perineal and penile skin loss can be significant and is difficult to repair. Various techniques have been used to reconstruct lost tissue: skin grafts, transposition of the testes and spermatic cords to the thigh, flaps, and other types of pediculated myocutaneous flaps. Muscle flap reconstruction provides an environment that allows for complete regeneration of the urethral epithelium but is bulky and unsightly. Skin grafts contract and may produce painful and dysfunctional reconstructions. This novel technique produces a functional, and aesthetic reconstruction. Conclusion Penile skin recovery following Fournier’s gangrene recovery is problematic. This case demonstrates the functionality of a delayed flap repair using the anterior abdominal wall.

  2. How do you tell whether a change in surgical technique leads to a change in outcome?

    Science.gov (United States)

    Vickers, Andrew J; Cronin, Angel M; Masterson, Timothy A; Eastham, James A

    2010-04-01

    Surgeons routinely evaluate and modify their surgical technique to improve patient outcome. It is also common for surgeons to analyze results before and after a change in technique to determine whether the change led to better results. Simple comparison of results before and after surgical modification may be confounded by the surgical learning curve. We developed a statistical method applicable to analyzing before/after surgical studies. We used simulation studies to compare different statistical analyses of before/after studies. We evaluated a simple 2-group comparison of results before and after the modification by the chi-square test and a novel bootstrap method that adjusts for the surgical learning curve. In the presence of the learning curve a simple 2-group comparison almost always showed an ineffective surgical modification to be of benefit. When the surgical modification was harmful, leading to a 10% decrease in the success rate, 2-group comparison nonetheless showed a statistically significant improvement in outcome about 80% of the time. The bootstrap method had only moderate power but did not show that ineffective surgical modifications were beneficial more than would be expected by chance. Simplistic approaches to the analysis of before/after surgical studies may lead to grossly erroneous results under the surgical learning curve. A straightforward alternative statistical method allows investigators to separate the effects of the learning curve from those of the surgical modification. Copyright (c) 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Intraoperative technique as a factor in the prevention of surgical site infection.

    LENUS (Irish Health Repository)

    McHugh, S M

    2012-02-01

    Approximately five percent of patients who undergo surgery develop surgical site infections (SSIs) which are associated with an extra seven days as an inpatient and with increased postoperative mortality. The competence and technique of the surgeon is considered important in preventing SSI. We have reviewed the evidence on different aspects of surgical technique and its role in preventing SSI. The most recent guidelines from the National Institute for Health and Clinical Excellence in the UK recommend avoiding diathermy for skin incision even though this reduces incision time and blood loss, both associated with lower infection rates. Studies comparing different closure techniques, i.e. continuous versus interrupted sutures, have not found a statistically significant difference in the SSI rate, but using continuous sutures is quicker. For contaminated wounds, the surgical site should be left open for four days to allow for treatment of local infection before subsequent healing by primary intention. Surgical drains should be placed through separate incisions, closed suction drains are preferable to open drains, and all drains should be removed as soon as possible. There are relatively few large studies on the impact of surgical techniques on SSI rates. Larger multicentre prospective studies are required to define what aspects of surgical technique impact on SSI, to better inform surgical practice and support education programmes for surgical trainees.

  4. Intraoperative technique as a factor in the prevention of surgical site infection.

    LENUS (Irish Health Repository)

    McHugh, S M

    2011-02-28

    Approximately five percent of patients who undergo surgery develop surgical site infections (SSIs) which are associated with an extra seven days as an inpatient and with increased postoperative mortality. The competence and technique of the surgeon is considered important in preventing SSI. We have reviewed the evidence on different aspects of surgical technique and its role in preventing SSI. The most recent guidelines from the National Institute for Health and Clinical Excellence in the UK recommend avoiding diathermy for skin incision even though this reduces incision time and blood loss, both associated with lower infection rates. Studies comparing different closure techniques, i.e. continuous versus interrupted sutures, have not found a statistically significant difference in the SSI rate, but using continuous sutures is quicker. For contaminated wounds, the surgical site should be left open for four days to allow for treatment of local infection before subsequent healing by primary intention. Surgical drains should be placed through separate incisions, closed suction drains are preferable to open drains, and all drains should be removed as soon as possible. There are relatively few large studies on the impact of surgical techniques on SSI rates. Larger multicentre prospective studies are required to define what aspects of surgical technique impact on SSI, to better inform surgical practice and support education programmes for surgical trainees.

  5. Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging

    Science.gov (United States)

    Elmi-Terander, Adrian; Skulason, Halldor; Söderman, Michael; Racadio, John; Homan, Robert; Babic, Drazenko; van der Vaart, Nijs; Nachabe, Rami

    2016-01-01

    Study Design. A cadaveric laboratory study. Objective. The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). Summary of Background Data. Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. Methods. ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. Results. ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. Conclusion. ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. Level of Evidence: N/A PMID:27513166

  6. Adolescent idiopathic scoliosis: sagital plane and low density pedicle screws

    Directory of Open Access Journals (Sweden)

    Rodrigo Augusto do Amaral

    2014-03-01

    Full Text Available OBJECTIVE: To examine the sagittal curves of patients treated with CD instrumentation using exclusively pedicle screws. METHODS: Image analysis of medical records of 27 patients (26 M and 1 F with a minimum follow-up of 6 months, who underwent surgical treatment in our service between January 2005 and December 2010. The curves were evaluated on coronal and sagittal planes, taking into account the potential correction of the technique. RESULTS: In the coronal plan the following curves were evaluated: proximal thoracic (TPx, main thoracic (TPp, and thoracolumbar; lumbar (TL, L, and the average flexibility was 52%, 52%, and 92% and the capacity of correction was 51%, 72%, and 64%, respectively. In the sagittal plane there was a mean increase in thoracic kyphosis (CT of 41% and an average reduction of lumbar lordosis (LL of 17%. Correlation analysis between variables showed Pearson coefficient of correlation of 0.053 and analysis of dispersion of R2 = <0.001. CONCLUSION: The method has shown satisfactory results with maintenance of kyphosis correction in patients with normal and hyper kyphotic deformities.

  7. Sacroiliac screw fixation: A mini review of surgical technique

    Directory of Open Access Journals (Sweden)

    Hernando Raphael Alvis-Miranda

    2014-01-01

    Full Text Available The sacral percutaneous fixation has many advantages but can be associated with a significant exposure to X-ray radiation. Currently, sacroiliac screw fixation represents the only minimally invasive technique to stabilize the posterior pelvic ring. It is a technique that should be used by experienced surgeons. We present a practical review of important aspects of this technique.

  8. Surgical treatment of Lenke 1 thoracic adolescent idiopathic scoliosis with maintenance of kyphosis using the simultaneous double-rod rotation technique.

    Science.gov (United States)

    Sudo, Hideki; Ito, Manabu; Abe, Yuichiro; Abumi, Kuniyoshi; Takahata, Masahiko; Nagahama, Ken; Hiratsuka, Shigeto; Kuroki, Kei; Iwasaki, Norimasa

    2014-06-15

    Retrospective analysis of a prospectively collected, consecutive, nonrandomized series of patients. To assess the surgical outcomes of the simultaneous double-rod rotation technique for treating Lenke 1 thoracic adolescent idiopathic scoliosis (AIS). With the increasing popularity of segmental pedicle screw spinal reconstruction for treating AIS, concerns regarding the limited ability to correct hypokyphosis have also increased. A consecutive series of 32 patients with Lenke 1 main thoracic AIS treated with the simultaneous double-rod rotation technique at our institution was included. Outcome measures included patient demographics, radiographical measurements, and Scoliosis Research Society questionnaire scores. All 32 patients were followed up for a minimum of 2 years (average, 3.6 yr). The average main thoracic Cobb angle correction rate and the correction loss at the final follow-up were 67.8% and 3.3°, respectively. The average preoperative thoracic kyphosis (T5-T12) was 11.9°, which improved significantly to 20.5° (P correction of the main thoracic curve while maintaining sagittal profiles and correcting coronal and axial deformities. 4.

  9. Surgical attenuation of congenital portosystemic shunts in dogs. Techniques, complications and prognosis

    NARCIS (Netherlands)

    Kummeling, A.|info:eu-repo/dai/nl/304828793

    2009-01-01

    The general aim of this thesis was to identify factors associated with outcome after surgical attenuation of congenital portosystemic shunts (CPSS) in dogs and to clarify underlying mechanisms of postoperative recovery in this disease. Two surgical techniques used for CPSS attenuation, ligation and

  10. Surgical techniques to minimize shoulder pain after laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Donatsky, Anders Meller; Bjerrum, Flemming; Gögenür, Ismayil

    2013-01-01

    intraoperative surgical methods applied to minimize incidence or severity of SP after LC. Only papers published in English were included. Data extracted were year of publication, number of participants and allocation, nonsignificant or significant effect on incidence or severity of SP. RESULTS: A total of 31...... papers where included in the review. Seven, 8, and 12 papers investigated the effect of drains, abdominal wall lift (AWL), and low-pressure pneumoperitoneum respectively. Four papers investigated drain suction, active gas aspiration, low insufflation flow or N(2)O insufflation respectively...

  11. PEDICLE TONGUE FLAP SURGERY IN ORAL SUBMUCOUS FIBROSIS

    Directory of Open Access Journals (Sweden)

    Muthubabu K

    2016-09-01

    Full Text Available BACKGROUND Oral submucous fibrosis is a disease of unknown aetiology and is a legacy of Indians. It has been variously treated both medically and surgically but neither has been found to be rewarding. Various groups have been studying the therapy schedules and aetiological association, but the conclusions have remained unclear. AIM The study aims to focus on newer surgical therapy stressing on the mechanics and use of pedicle tongue flap in the management of this condition. METHODS AND MATERIALS The study comprised of 40 patients from our outpatient department suffering from oral submucous fibrosis in the age group of 11 to 70 years. The contributory factors of oral submucous fibrosis and the symptoms of the disease were evaluated and the role of pedicle tongue flap surgery in the management of this disease which is a premalignant condition is discussed. RESULTS AND CONCLUSION Pedicle tongue flap surgery has given promising results in the treatment of trismus due to oral submucous fibrosis. After the surgery, none of our patients developed any malignant change.

  12. OUTCOMES OF HILAR PEDICLE CONTROL USING SUTURE LIGATION DURING LAPAROSCOPIC SPLENECTOMY.

    Science.gov (United States)

    Makgoka, M

    2017-06-01

    Laparoscopic splenectomy is a well described gold standard procedure for various indications. One of the key steps during laparoscopic splenectomy is the hilar pedicle vessels control, which can be challenging in most cases. Most centres around the world recommend the use Ligaclib or endovascular staplers as Methods of choice for hilar pedicle control but the issue is the cost and efficiency of the laparoscopic haemostatic devices. A descriptive retrospective study of patients who had laparoscopic splenectomy from 2013 to present. Hilar splenic vessel control was done with suture ligation. We looked at outcomes of patients offered this technique, complications of this technique, and describing the technique of hilar control in laparoscopic splenectomy. Total of 27 patients had laparoscopic splenectomy with splenic hilar pedicle control with suture ligation. Mean operative time, mean blood volume loss, length of hospital stay, postoperative complications conversion to laparotomy. Laparoscopic hilar pedicle control with suture ligation is safe and effective for the patient in our hospital setting.

  13. Surgical techniques for quantitative nutrient digestion and absorbtion studies in the pig

    DEFF Research Database (Denmark)

    Jørgensen, Henry; Serena, Anja; Theil, Peter Kappel

    2010-01-01

    Surgical techniques allow quantitative measurement of nutrient digestion and absorption in pigs. The present paper presents our updated techniques for anaesthesia and surgery. The surgery technique of catheterization of the portal vein, mesenteric vein and mesenteric artery, as well as the fitting...

  14. Safety and surgical techniques of C1 lateral mass screws

    International Nuclear Information System (INIS)

    Kubo, Shinichiro; Kuroki, Hiroshi; Hanado, Shoji; Hamanaka, Hideaki; Inomata, Naoki; Kuroki, Shuji; Chosa, Etsuo

    2010-01-01

    The objectives of this study were to evaluate the proper insertion techniques of C1 lateral mass screws. Eighteen consecutive patients were examined after upper cervical fusion using twenty-nine C1 lateral mass screws. Screws were placed by three different techniques; Goel's technique (4), Tan's technique (20), Notching technique (5). Pre and post-operative CT scans with multiplanar reconstruction were used to detect cortical breaches and direction of screws. No transverse foramen and vertebral groove violation was found in CT scans. Three had breached superior articular facet of the atlas. However, the range of motion (R.O.M) of atlanto-occipital joints had not changed postoperatively. Theses screws were inserted with Tan's technique and two of three were directed medially. It is feasible to safely insert C1 lateral mass screws when correct insertion point and direction are considered preoperatively. However, care should be taken because screws can violate the atlanto-occipital joint especially with Tan's technique. (author)

  15. Application of minimally invasive technique in surgical treatment of pancreatic diseases

    Directory of Open Access Journals (Sweden)

    ZHANG Yixi

    2015-05-01

    Full Text Available In recent years, with the rapid development of minimally invasive concept, from laparoscopic operation to three-dimension laparoscopic technique and to robotic surgical system, treatment modalities have changed a lot. Pancreatic diseases, including multiple lesions, have different prognoses. An appropriate surgical procedure should be selected while ensuring the radical treatment of disease, so as to minimize the injury to patients and the impairment of organ function. Minimally invasive technique is of great significance in the surgical treatment of pancreatic diseases.

  16. PREFERED SURGICAL TECHNIQUE USED BY ORTHOPEDISTS IN ACUTE ACROMIOCLAVICULAR DISLOCATION

    Science.gov (United States)

    NISHIMI, ALEXANDRE YUKIO; ARBEX, DEMETRIO SIMÃO; MARTINS, DIOGO LUCAS CAMPOS; GUSMÃO, CARLOS VINICIUS BUARQUE DE; BONGIOVANNI, ROBERTO RANGEL; PASCARELLI, LUCIANO

    2016-01-01

    ABSTRACT Objective: To determine whether training on shoulder and elbow surgery influences the orthopedist surgeons' preferred technique to address acute acromioclavicular joint dislocation (ACD). Methods: A survey was conducted with shoulder and elbow specialists and general orthopedists on their preferred technique to address acute ACD. Results: Thirty specialists and forty-five general orthopedists joined the study. Most specialists preferred the endobutton technique, while most general orthopedists preferred the modified Phemister procedure for coracoclavicular ligament repair using anchors. We found no difference between specialists and general orthopedists in the number of tunnels used to repair the coracoclavicular ligament; preferred method for wire insertion through the clavicular tunnels; buried versus unburied Kirschner wire insertion for acromioclavicular temporary fixation; and time for its removal; and regarding the suture thread used for deltotrapezoidal fascia closure. Conclusion: Training on shoulder and elbow surgery influences the surgeons' preferred technique to address acute ACD. Level of Evidence V, Expert Opinion. PMID:28149190

  17. Comparison of two surgical techniques in large incisional hernias

    Directory of Open Access Journals (Sweden)

    Mustafa Sit

    2014-03-01

    Full Text Available Objectives: Incisional hernias occur from incisions of previous abdominal operations. It is an often complication of abdominal interventions. Prevalence of incisional hernias is approximately 2.9% and 3.6% in vertical midline incisions and transverse incisions, respectively. Incisional hernias cause morbidity and loss of manpower. The only treatment option is surgery. We aimed to compare surgical methods of incisional hernias and discuss the postoperative data in this retrospective report. Methods: We retrospectively analyzed the data of 54 patients with large incisional hernias operated between 2007 and 2011. Results: We compared age, chronic diseases (e.g. Chronic obstructive pulmonary disease, diabetes mellitus,which may cause postoperative recurrence, gender, personal factors, such as patients undergoing incisional hernia repair mesh over solid fascia less or over than 5 cm with the placement of decolation; recurrence, the development of postoperative seroma, receiving postoperative drainage and postoperative length of hospital stay were compared. While the recurrence rate of less than 5 cm above the decolation; seroma development, no significant difference in length of hospital stay and drain times to get. Conclusion: In conclusion, we think that recurrence rate should be reduced by dissection of 5 cm intact fascia and grafting in incisional hernias of anterior abdominal wall. J Clin Exp Invest 2014; 5 (1: 36-39

  18. Assessing suturing techniques using a virtual reality surgical simulator.

    Science.gov (United States)

    Kazemi, Hamed; Rappel, James K; Poston, Timothy; Hai Lim, Beng; Burdet, Etienne; Leong Teo, Chee

    2010-09-01

    Advantages of virtual-reality simulators surgical skill assessment and training include more training time, no risk to patient, repeatable difficulty level, reliable feedback, without the resource demands, and ethical issues of animal-based training. We tested this for a key subtask and showed a strong link between skill in the simulator and in reality. Suturing performance was assessed for four groups of participants, including experienced surgeons and naive subjects, on a custom-made virtual-reality simulator. Each subject tried the experiment 30 times using five different types of needles to perform a standardized suture placement task. Traditional metrics of performance as well as new metrics enabled by our system were proposed, and the data indicate difference between trained and untrained performance. In all traditional parameters such as time, number of attempts, and motion quantity, the medical surgeons outperformed the other three groups, though differences were not significant. However, motion smoothness, penetration and exit angles, tear size areas, and orientation change were statistically significant in the trained group when compared with untrained group. This suggests that these parameters can be used in virtual microsurgery training.

  19. Morphology of the atlas pedicle revisited: a morphometric CT-based study on 120 patients.

    Science.gov (United States)

    Qian, Li-Xiong; Hao, Ding-Jun; He, Bao-Rong; Jiang, Yong-Hong

    2013-05-01

    To quantify the dimensions of the atlas pedicles and to analyze the relationship between extra medullary height (EMH) with intra medullary height (IMH) of the atlas pedicle. The images of the patients who had CT scanning and three-dimensional (3D) reconstruction involving atlantoaxial complex between June 2011 and April 2012 and meet our inclusion criteria were studied retrospectively. After reformatting the original images, the EMH and IMH of the atlas pedicles were measured. Extra medullary height and IMH were, respectively, 4.83 ± 1.13 and 1.29 ± 1.10 mm for males and 3.75 ± 0.93 and 0.60 ± 0.83 mm for females, with statistical difference (P atlas pedicles were measured by using CT images of the atlas, providing anatomic parameters for surgery. They showed a certain correlation but with a high variability. C1 pedicle screw fixation was well performed when the medullary canal was ≥1 mm, but the surgical procedure should be careful when it was between 0 and 1 mm, and avoided when there was no medullary canal in the atlas pedicle! So 3D CT reconstruction should be conducted to obtain data and establish individualized fixation strategy preoperatively.

  20. What matters after sleeve gastrectomy: patient characteristics or surgical technique?

    Science.gov (United States)

    Dhar, Vikrom K; Hanseman, Dennis J; Watkins, Brad M; Paquette, Ian M; Shah, Shimul A; Thompson, Jonathan R

    2018-03-01

    The impact of operative technique on outcomes in laparoscopic sleeve gastrectomy has been explored previously; however, the relative importance of patient characteristics remains unknown. Our aim was to characterize national variability in operative technique for laparoscopic sleeve gastrectomy and determine whether patient-specific factors are more critical to predicting outcomes. We queried the database of the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program for laparoscopic sleeve gastrostomies performed in 2015 (n = 88,845). Logistic regression models were used to determine predictors of postoperative outcomes. In 2015, >460 variations of laparoscopic sleeve gastrectomy were performed based on combinations of bougie size, distance from the pylorus, use of staple line reinforcement, and oversewing of the staple line. Despite such substantial variability, technique variants were not predictive of outcomes, including perioperative morbidity, leak, or bleeding (all P ≥ .05). Instead, preoperative patient characteristics were found to be more predictive of these outcomes after laparoscopic sleeve gastrectomy. Only history of gastroesophageal disease (odds ratio 1.44, 95% confidence interval 1.08-1.91, P < .01) was associated with leak. Considerable variability exists in technique among surgeons nationally, but patient characteristics are more predictive of adverse outcomes after laparoscopic sleeve gastrectomy. Bundled payments and reimbursement policies should account for patient-specific factors in addition to current accreditation and volume thresholds when deciding risk-adjustment strategies. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Surgical Anatomy and Microvascular Surgical Technique Relevant to Experimental Renal Transplant in Rat Employing Aortic and Inferior Venacaval Conduits.

    Science.gov (United States)

    Shrestha, Badri Man; Haylor, John

    2017-11-15

    Rat models of renal transplant are used to investigate immunologic processes and responses to therapeutic agents before their translation into routine clinical practice. In this study, we have described details of rat surgical anatomy and our experiences with the microvascular surgical technique relevant to renal transplant by employing donor inferior vena cava and aortic conduits. For this study, 175 rats (151 Lewis and 24 Fisher) were used to establish the Fisher-Lewis rat model of chronic allograft injury at our institution. Anatomic and technical details were recorded during the period of training and establishment of the model. A final group of 12 transplanted rats were studied for an average duration of 51 weeks for the Lewis-to-Lewis isografts (5 rats) and 42 weeks for the Fisher-to-Lewis allografts (7 rats). Functional measurements and histology confirmed the diagnosis of chronic allograft injury. Mastering the anatomic details and microvascular surgical techniques can lead to the successful establishment of an experimental renal transplant model.

  2. Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging: A Spine Cadaveric Feasibility and Accuracy Study.

    Science.gov (United States)

    Elmi-Terander, Adrian; Skulason, Halldor; Söderman, Michael; Racadio, John; Homan, Robert; Babic, Drazenko; van der Vaart, Nijs; Nachabe, Rami

    2016-11-01

    A cadaveric laboratory study. The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. N/A.

  3. A modified surgical technique for reconstruction of an acute acromioclavicular joint dislocation

    Science.gov (United States)

    Marchie, Anthony; Kumar, Arun; Catre, Melanio

    2009-01-01

    We report a modified surgical technique for reconstruction of coracoclavicular and acromioclavicular ligaments after acute dislocation of acromioclavicular joint using suture anchors. We have repaired 3 consecutive type III acromioclavicular dislocations with good results. This technique is simple and safe and allows anatomical reconstruction of the ligaments in acute dislocations. PMID:20671868

  4. A modified surgical technique for reconstruction of an acute acromioclavicular joint dislocation

    OpenAIRE

    Marchie, Anthony; Kumar, Arun; Catre, Melanio

    2009-01-01

    We report a modified surgical technique for reconstruction of coracoclavicular and acromioclavicular ligaments after acute dislocation of acromioclavicular joint using suture anchors. We have repaired 3 consecutive type III acromioclavicular dislocations with good results. This technique is simple and safe and allows anatomical reconstruction of the ligaments in acute dislocations.

  5. Innovation in surgical technology and techniques: Challenges and ethical issues.

    Science.gov (United States)

    Geiger, James D; Hirschl, Ronald B

    2015-06-01

    The pace of medical innovation continues to increase. The deployment of new technologies in surgery creates many ethical challenges including how to determine safety of the technology, what is the timing and process for deployment of a new technology, how are patients informed before undergoing a new technology or technique, how are the outcomes of a new technology evaluated and how are the responsibilities of individual patients and society at large balanced. Ethical considerations relevant to the implementation of ECMO and robotic surgery are explored to further discussion of how we can optimize the delicate balance between innovation and regulation. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Minimally Invasive Surgical Approach to Distal Fibula Fractures: A Technique Tip

    Directory of Open Access Journals (Sweden)

    Tyler A. Gonzalez

    2017-01-01

    Full Text Available Wound complications following ankle fracture surgery are a major concern. Through the use of minimally invasive surgical techniques some of these complications can be mitigated. Recent investigations have reported on percutaneous fixation of distal fibula fractures demonstrating similar radiographic and functional outcomes to traditional open approaches. The purpose of this manuscript is to describe in detail the minimally invasive surgical approach for distal fibula fractures.

  7. Pedicle screw-rod fixation: a feasible treatment for dogs with severe degenerative lumbosacral stenosis.

    Science.gov (United States)

    Tellegen, Anna R; Willems, Nicole; Tryfonidou, Marianna A; Meij, Björn P

    2015-12-07

    Degenerative lumbosacral stenosis is a common problem in large breed dogs. For severe degenerative lumbosacral stenosis, conservative treatment is often not effective and surgical intervention remains as the last treatment option. The objective of this retrospective study was to assess the middle to long term outcome of treatment of severe degenerative lumbosacral stenosis with pedicle screw-rod fixation with or without evidence of radiological discospondylitis. Twelve client-owned dogs with severe degenerative lumbosacral stenosis underwent pedicle screw-rod fixation of the lumbosacral junction. During long term follow-up, dogs were monitored by clinical evaluation, diagnostic imaging, force plate analysis, and by using questionnaires to owners. Clinical evaluation, force plate data, and responses to questionnaires completed by the owners showed resolution (n = 8) or improvement (n = 4) of clinical signs after pedicle screw-rod fixation in 12 dogs. There were no implant failures, however, no interbody vertebral bone fusion of the lumbosacral junction was observed in the follow-up period. Four dogs developed mild recurrent low back pain that could easily be controlled by pain medication and an altered exercise regime. Pedicle screw-rod fixation offers a surgical treatment option for large breed dogs with severe degenerative lumbosacral stenosis with or without evidence of radiological discospondylitis in which no other treatment is available. Pedicle screw-rod fixation alone does not result in interbody vertebral bone fusion between L7 and S1.

  8. Pectus bar removal: surgical technique and strategy to avoid complications.

    Science.gov (United States)

    Park, Hyung Joo; Kim, Kyung Soo

    2016-01-01

    Pectus bar removal is the final stage of the procedure for minimally invasive repair of pectus excavatum. Based on our experience with one of the largest scale data, we would like to address the important issues in pectus bar removal, such as appropriate duration of bar maintenance, techniques for bar removal, and strategies to avoid complications. Between September 1999 and August 2015, we operated on 2,553 patients with pectus excavatum and carinatum using pectus bars for a minimally invasive approach. Among them, 1,821 patients (71.3%) underwent pectus bar removal as a final stage of pectus deformity repair, and their data were analyzed retrospectively to identify the outcomes and adverse effects of the pectus bar removal procedure. The mean age of the patients was 9.13 years (range, 16 months to 44 years) and the male to female ratio was 3.55. The study is approved by the Institutional Review Board (IRB), the ethical committee of Seoul St. Mary's Hospital. The IRB has exempted the informed consent from every patient in this study due to this is a retrospective chart review without revealing any patients' personal data. Our technique involved straightening of the bar in a supine position. The overall mean duration of pectus bar maintenance was 2.57 years (range, 4 months to 14 years). The mean duration was 2.02 years (range, 4 months to 7 years) for children under 12 years, 2.99 years (range, 7 months to 9 years) for teenagers aged 12-20 years, and 3.53 years (range, 3 months to 14 years) for adults over 20 years. Forty-eight patients (2.6%) underwent bar removal more than 5 years after bar insertion and 58 patients (3.2%) underwent bar removal earlier than initially planned. The most common adverse reaction after bar removal was wound seroma including infection (43 patients, 2.36%). Recurrence after bar removal occurred in nine patients (0.49%), and seven of these required redo repair (0.38%). Pectus bar removal is a safe and straightforward procedure with a

  9. Outcome of different oncoplastic surgical (OPs) techniques for centrally located breast cancer (CLBC)

    International Nuclear Information System (INIS)

    Moustafa, A.; Fakhr, I.

    2014-01-01

    Background: Oncoplastic breast surgery is a standard treatment of early breast cancer, offering a balance between good cosmetic outcome and limited risk of locoregional recurrence, by enabling proper resection margins. Aim of study: To present multiple techniques of partial breast reconstruction following the resection of centrally located breast cancer (CLBC) resection. Patients and methods: From January 2011 to August 2014, 21 patients underwent central quadrantectomy for carcinoma of the central region of the breast. Excisions included the nipple/areola complex, in most of the cases, down to the pectoralis fascia with a wide safety margin, and proper axillary management. Oncoplastic approaches included latissimus dorsi flap, inferior pedicle flap, Melon slice, Grisotti and round block techniques. Results: Mean age of patients was 49.5 ± 10.61 years. Tumor size ranged from 1.5 to 4.5 cm. Postoperative pathology revealed a tumor mean safety margin of 2.5± 0.83 cm, with positive axillary lymph nodes in 15 (75.0%) patients. Nineteen (95.0%) patients received postoperative breast radiotherapy, while 9/20 (45.0%) and 3/20 (15.0%) received adjuvant chemotherapy or hormonal therapy, respectively, and only 8/20 (40.0%) patients received both therapies. During a median follow- up period of 14.89 months, neither local nor distant metastasis, were detected. The postoperative cosmetic result evaluated by the patients was excellent in 6/20 patients (30.0%), good in 11/20 patients (55.0%), fair in 3/20 (15.0%) with neither poor nor bad results, with an overall mean of 4.0 ± 0.5 equivalent to 80% satisfaction. Conclusion: Multiple oncoplastic breast surgery techniques can be used for the resection of CLBC with satisfying cosmetic outcomes.

  10. A novel route for placing free flap pedicle from a palatal defect

    Directory of Open Access Journals (Sweden)

    Rajeev B Ahuja

    2014-01-01

    Full Text Available One of the better options available to repair a large palatal defect is by employing a free flap. Almost all the times such free flaps are plumbed to facial vessels. The greatest challenge in such cases is the placement of the pedicle from palatal shelf to recipient vessels because there is no direct route available. As majority of large palatal fistulae are encountered in operated cleft palates there is a possibility of routing the pedicle through a cleft in the maxillary arch or via pyriform aperture. When such a possibility doesn′t exist the pedicle is routed behind the maxillary arch. We describe a novel technique of pedicle placement through a maxillary antrostomy, in this case report, where a large palatal fistula in a 16 year old boy was repaired employing a free radial artery forearm flap. The direct route provided by maxillary antrostomy is considered the most expeditious of all possibilities mentioned above.

  11. A New Electromagnetic Navigation System for Pedicle Screws Placement: A Human Cadaver Study at the Lumbar Spine.

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    comparable.EMF navigation offers a high accuracy in Pedicle screw placement with additional advantages compared to other techniques. The short set-up time and easy handling of EMF navigation should be emphasized. Additional advantages are the absence of intraoperative radiation exposure for the operator and surgical team in the current set-up and the operator's free mobility without interfering with navigation. Further studies with navigation at higher levels of the spine, larger numbers of cases and studies with control group are planned.

  12. Radical prostatectomy: evolution of surgical technique from the laparoscopic point of view

    Directory of Open Access Journals (Sweden)

    Xavier Cathelineau

    2010-04-01

    Full Text Available PURPOSE: To review the literature and present a current picture of the evolution in radical prostatectomy from the laparoscopic point of view. MATERIALS AND METHODS: We conducted an extensive Medline literature search. Articles obtained regarding laparoscopic radical prostatectomy (LRP and our experience at Institut Montsouris were used for reassessing anatomical and technical issues in radical prostatectomy. RESULTS: LRP nuances were reassessed by surgical teams in order to verify possible weaknesses in their performance. Our basic approach was to carefully study the anatomy and pioneer open surgery descriptions in order to standardized and master a technique. The learning curve is presented in terms of an objective evaluation of outcomes for cancer control and functional results. In terms of technique-outcomes, there are several key elements in radical prostatectomy, such as dorsal vein control-apex exposure and nerve sparing with particular implications in oncological and functional results. Major variations among the surgical teams' performance and follow-up prevented objective comparisons in radical prostatectomy. The remarkable evolution of LRP needs to be supported by comprehensive results. CONCLUSIONS: Radical prostatectomy is a complex surgical operation with difficult objectives. Surgical technique should be standardized in order to allow an adequate and reliable performance in all settings, keeping in mind that cancer control remains the primary objective. Reassessing anatomy and a return to basics in surgical technique is the means to improve outcomes and overcome the difficult task of the learning curve, especially in minimally access urological surgery.

  13. An innovative surgical technique for treating penile incarceration injury caused by heavy metallic ring

    Directory of Open Access Journals (Sweden)

    S J Baruah

    2009-01-01

    Full Text Available Penile incarceration injury by heavy metallic ring is a rare genital injury. A man may place metal object for erotic or autoerotic purposes, for masturbation or increasing erection, and due to psychiatric disturbances are some of the reasons for a penile incarceration injury. The incarcerating injury results in reduced blood flow distal to the injury, leading to edema, ischemia, and sometimes gangrene. These injuries are divided into five grades and their treatment options are divided into four groups. Surgical techniques are reserved for the advanced grades (Grades IV and V. We describe an innovative surgical technique, which can be adopted in Grades II and III injuries.

  14. Evaluation of primary and secondary stability of titanium implants using different surgical techniques.

    Science.gov (United States)

    Tabassum, Afsheen; Meijer, Gert J; Walboomers, X Frank; Jansen, John A

    2014-04-01

    To investigate the influence of different surgical techniques on the primary and secondary implant stability using trabecular bone of goats as an implantation model. In the iliac crest of eight goats, 48 cylindrical-screw-type implants with a diameter of 4.2 mm (Dyna(®) ; Bergen op Zoom, the Netherlands) were installed, using three different surgical techniques: (i) 5% undersized, using a final drill diameter of 4 mm; (ii) 15% undersized, using a final drill diameter of 3.6 mm; and (iii) 25% undersized, using a final drill diameter of 3.2 mm. Peak insertion torque values were measured by a Digital(®) (MARK-10 Corporation, New York, NY, USA) torque gauge instrument during placement. At 3 weeks after implantation, removal torque was measured. Histomorphometrically, the peri-implant bone volume was measured in three zones; the inner zone (0-500 μm), the middle zone (500-1000 μm) and the outer zone (1000-1500 μm). Evaluation of the obtained data demonstrated no statistically significant difference between different surgical techniques regarding removal torque values. With respect to the percentage peri-implant bone volume (%BV), also no significant difference could be observed between all three applied surgical techniques for both the inner, middle and outer zone. However, irrespective of the surgical technique, it was noticed that the %BV was significantly higher for the inner zone as compared to middle and outer zone (P < 0.05) around the implant. At 3 weeks after implant installation, independent of the used undersized surgical technique, the %BV in the inner zone (0-500 μm) peri-implant area was improved due to both condensation of the surrounding bone as also the translocation of host bone particles along the implant surface. Surprisingly, no mechanical beneficial effect of the 25% undersized surgical technique could be observed as compared to the 5% or 15% undersized surgical technique to improve primary or secondary implant stability. © 2013

  15. Safety of lumbar spine radiofrequency procedures in the presence of posterior pedicle screws: technical report of a cadaver study.

    Science.gov (United States)

    Gazelka, Halena M; Welch, Tasha L; Nassr, Ahmad; Lamer, Tim J

    2015-05-01

    To determine whether the thermal energy associated with lumbar spine radiofrequency neurotomy (RFN) performed near titanium and stainless steel pedicle screws is conducted to the pedicle screws or adjacent tissues, or both, thus introducing potential for thermal damage to those tissues. Cadaver study. Cadaver laboratory equipped with fluoroscopy, surgical spine implements, and radiofrequency generator. No live human subject; a fresh frozen (and thawed) cadaver torso was used for the study. Titanium and stainless steel pedicle screws were placed in the lumbar spine of a fresh frozen cadaver torso with real-time fluoroscopic guidance. Conventional RFN cannula placement was performed at the level of pedicle screws and a control (nonsurgically altered) lumbar level. Neurotomy was performed with conventional radiofrequency lesioning parameters. Temperatures were recorded at multiple sites through thermistor probes. Direct contact of the radiofrequency cannula with the pedicle screws during conventional RFN produced a substantial increase in temperature in the surrounding soft tissues. A small increase in temperature occurred at the same sites at the control level. Titanium and stainless steel pedicle screws are capable of sustaining large increases in temperature when the radiofrequency probe comes in contact with the screw. These results are suggestive that pedicle screws could serve as a possible source of tissue heating and thermal injury during RFN. Wiley Periodicals, Inc.

  16. Pedicle streaking: A novel and simple aid in pedicle positioning in free tissue transfer

    Directory of Open Access Journals (Sweden)

    Aditya Aggarwal

    2015-01-01

    Full Text Available Introduction: The pedicle positioning in free tissue transfer is critical to its success. Long thin pedicles are especially prone to this complication where even a slight twist in the perforator can result in flap loss. Pedicles passing through the long tunnels are similarly at risk. Streaking the pedicle with methylene blue is a simple and safe method which increases the safety of free tissue transfer. Materials and Methods: Once the flap is islanded on the pedicle and the vascularity of the flap is confirmed, the pedicle is streaked with methylene blue dye at a distance of 6-7 mm. The streaking starts from the origin of the vessels and continued distally on to the under surface of flap to mark the complete course of the pedicle in alignment. The presence of streaking in some parts and not in rest indicates twist in the pedicle. Observation and Results: Four hundred and sixty five free flaps have been done at our centre in the last 5 years. The overall success rate of free flaps is 95.3% (22 free flap failures. There has not been a single case of pedicle twist leading to flap congestion and failure. Conclusion: This simple and novel method is very reliable for pedicle positioning avoiding any twist necessary for successful free tissue transfer.

  17. Surgical robotics beyond enhanced dexterity instrumentation: a survey of machine learning techniques and their role in intelligent and autonomous surgical actions.

    Science.gov (United States)

    Kassahun, Yohannes; Yu, Bingbin; Tibebu, Abraham Temesgen; Stoyanov, Danail; Giannarou, Stamatia; Metzen, Jan Hendrik; Vander Poorten, Emmanuel

    2016-04-01

    Advances in technology and computing play an increasingly important role in the evolution of modern surgical techniques and paradigms. This article reviews the current role of machine learning (ML) techniques in the context of surgery with a focus on surgical robotics (SR). Also, we provide a perspective on the future possibilities for enhancing the effectiveness of procedures by integrating ML in the operating room. The review is focused on ML techniques directly applied to surgery, surgical robotics, surgical training and assessment. The widespread use of ML methods in diagnosis and medical image computing is beyond the scope of the review. Searches were performed on PubMed and IEEE Explore using combinations of keywords: ML, surgery, robotics, surgical and medical robotics, skill learning, skill analysis and learning to perceive. Studies making use of ML methods in the context of surgery are increasingly being reported. In particular, there is an increasing interest in using ML for developing tools to understand and model surgical skill and competence or to extract surgical workflow. Many researchers begin to integrate this understanding into the control of recent surgical robots and devices. ML is an expanding field. It is popular as it allows efficient processing of vast amounts of data for interpreting and real-time decision making. Already widely used in imaging and diagnosis, it is believed that ML will also play an important role in surgery and interventional treatments. In particular, ML could become a game changer into the conception of cognitive surgical robots. Such robots endowed with cognitive skills would assist the surgical team also on a cognitive level, such as possibly lowering the mental load of the team. For example, ML could help extracting surgical skill, learned through demonstration by human experts, and could transfer this to robotic skills. Such intelligent surgical assistance would significantly surpass the state of the art in surgical

  18. Outcome of Vaginoplasty in Male-to-Female Transgenders: A Systematic Review of Surgical Techniques.

    Science.gov (United States)

    Horbach, Sophie E R; Bouman, Mark-Bram; Smit, Jan Maerten; Özer, Müjde; Buncamper, Marlon E; Mullender, Margriet G

    2015-06-01

    Gender reassignment surgery is the keystone of the treatment of transgender patients. For male-to-female transgenders, this involves the creation of a neovagina. Many surgical methods for vaginoplasty have been opted. The penile skin inversion technique is the method of choice for most gender surgeons. However, the optimal surgical technique for vaginoplasty in transgender women has not yet been identified, as outcomes of the different techniques have never been compared. With this systematic review, we aim to give a detailed overview of the published outcomes of all currently available techniques for vaginoplasty in male-to-female transgenders. A PubMed and EMBASE search for relevant publications (1995-present), which provided data on the outcome of techniques for vaginoplasty in male-to-female transgender patients. Main outcome measures are complications, neovaginal depth and width, sexual function, patient satisfaction, and improvement in quality of life (QoL). Twenty-six studies satisfied the inclusion criteria. The majority of these studies were retrospective case series of low to intermediate quality. Outcome of the penile skin inversion technique was reported in 1,461 patients, bowel vaginoplasty in 102 patients. Neovaginal stenosis was the most frequent complication in both techniques. Sexual function and patient satisfaction were overall acceptable, but many different outcome measures were used. QoL was only reported in one study. Comparison between techniques was difficult due to the lack of standardization. The penile skin inversion technique is the most researched surgical procedure. Outcome of bowel vaginoplasty has been reported less frequently but does not seem to be inferior. The available literature is heterogeneous in patient groups, surgical procedure, outcome measurement tools, and follow-up. Standardized protocols and prospective study designs are mandatory for correct interpretation and comparability of data. © 2015 International Society for

  19. Hereditary spherocytosis and partial splenectomy in children: review of surgical technique and the role of imaging

    International Nuclear Information System (INIS)

    Hollingsworth, Caroline L.; Rice, Henry E.

    2010-01-01

    The risks associated with total splenectomy, including overwhelming postsplenectomy infection, have led to an interest in the use of partial splenectomy as an alternative surgical option for children with congenital hemolytic anemias and hypersplenism. Partial splenectomy, a procedure designed to remove enough spleen to improve anemia and avoid complications of splenic sequestration while preserving splenic function, has shown promise in children. Radiologic imaging is essential for the preoperative evaluation and postoperative care for children undergoing partial splenectomy and offers a broad range of critical clinical information essential for care of these complex children. It is imperative for radiologists involved in the care of these children to be familiar with the surgical technique and imaging options for these procedures. This article reviews the surgical technique as well as the current status of various diagnostic imaging options used for children undergoing partial splenectomy, highlighting technical aspects and specific clinical information obtained by each modality. (orig.)

  20. Hereditary spherocytosis and partial splenectomy in children: review of surgical technique and the role of imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hollingsworth, Caroline L. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States); Rice, Henry E. [Duke University Medical Center, Department of Surgery, Durham, NC (United States)

    2010-07-15

    The risks associated with total splenectomy, including overwhelming postsplenectomy infection, have led to an interest in the use of partial splenectomy as an alternative surgical option for children with congenital hemolytic anemias and hypersplenism. Partial splenectomy, a procedure designed to remove enough spleen to improve anemia and avoid complications of splenic sequestration while preserving splenic function, has shown promise in children. Radiologic imaging is essential for the preoperative evaluation and postoperative care for children undergoing partial splenectomy and offers a broad range of critical clinical information essential for care of these complex children. It is imperative for radiologists involved in the care of these children to be familiar with the surgical technique and imaging options for these procedures. This article reviews the surgical technique as well as the current status of various diagnostic imaging options used for children undergoing partial splenectomy, highlighting technical aspects and specific clinical information obtained by each modality. (orig.)

  1. Surgical complications in 2,840 cases of hemorrhoidectomy by Milligan-Morgan, Ferguson and combined techniques

    Directory of Open Access Journals (Sweden)

    Guilherme de Almeida Santos

    2012-09-01

    relation to age decades. The most common technique for anal stenosis was single anotomy without sphincterotomy (46.0%. All cases of anal bleeding had surgical ligation of all hemorrhoidal pedicles, no matter if the bleeding site was found or not.O seguimento de uma casuística de 2.840 hemorroidectomias pelas técnicas de Milligan-Morgan (2.189 casos, Ferguson (341 casos e mista (310 casos em 11.043 pacientes portadores de doença hemorroidária (DH permitiu as seguintes conclusões. A aceitação da indicação cirúrgica para doença hemorroidária (DH, pelos pacientes, foi de 25,7%. A doença hemorroidária (DH foi mais comum entre mulheres (53,8% que em homens (46,2% e a hemorroidectomia foi mais aceita pelas mulheres (26,5% que pelos homens (24,8%. A hemorroidectomia foi mais realizada em pacientes de quarta (27,7%, quinta (21,9% e terceira (21,0% décadas etárias. Os pacientes que mais aceitaram a indicação cirúrgica foram os da segunda (38,2%, oitava (35,9% e nona (34,5% décadas etárias. A incidência global de complicações cirúrgicas foi de 3,0% (87 casos: estenose anal (1,8%, hemorragia grave (0,8%, agravamento da hipotonia anal (0,2%, sepse (0,1% e sistêmicas (0,1%, sem diferença entre as técnicas usadas. A incidência de complicações cirúrgicas pela técnica de Milligan-Morgan foi de 3,0%: estenose (1,9%, hemorragia grave (1,9%, agravamento da hipotonia anal (0,2% e sistêmicas (0,04%. A incidência de complicações cirúrgicas pela técnica de Ferguson foi de 3,5%: estenose (1,7%, hemorragia grave (0,6%, agravamento da hipotonia anal (0,6% e sepse (0,6%. A incidência de complicações cirúrgicas pela técnica mista foi de 2,5%: estenose (1,0%, hemorragia grave (0,3%, agravamento da hipotonia anal (0,3%, sepse (0,3% e sistêmicas (0,3%. A incidência de complicações cirúrgicas pelos gêneros foi de 3,0% entre as mulheres e 3,2% entre os homens, com maior incidência de estenose nas mulheres (2,0% e hemorragia nos homens (1,1%. As décadas em

  2. SURGICAL TECHNIQUE

    African Journals Online (AJOL)

    We describe a simple form of posterior spinal surgery for patients with tuberculous ... malnutrition and other concomitant diseases tuberculosis (T B) of ... Positioning: We use the prone position with hip and .... can fracture, get absorbed or slip.

  3. Triple-Tube-Ostomy: A Novel Technique for the Surgical Treatment of Iatrogenic Duodenal Perforation

    Directory of Open Access Journals (Sweden)

    Nobuaki Fujikuni

    2011-12-01

    Full Text Available Although duodenal perforation is currently an infrequent complication of medical procedures, its incidence in the future predictably will increase as endoscopic treatment of duodenal neoplasms becomes more frequently used. In some cases, duodenal perforation is difficult to treat even surgically. We report here a novel technique called ‘triple-tube-ostomy’ for the treatment of iatrogenic duodenal perforation. Since November 2009, there have been three cases of iatrogenic perforation of the duodenum, due to various causes, which we have treated with our novel technique. The main principles of the technique are biliary diversion, decompression of the duodenum, and early enteral nutrition. All patients who underwent the triple-tube-ostomy procedure had good postoperative courses, with few complications. The novel surgical technique we describe in this report is safe, reliable, easy to learn and perform, and led to a good postoperative course in all cases where we performed it.

  4. Posterior Segment Intraocular Foreign Body: Extraction Surgical Techniques, Timing, and Indications for Vitrectomy

    Directory of Open Access Journals (Sweden)

    Dante A. Guevara-Villarreal

    2016-01-01

    Full Text Available Ocular penetrating injury with Intraocular Foreign Body (IOFB is a common form of ocular injury. Several techniques to remove IOFB have been reported by different authors. The aim of this publication is to review different timing and surgical techniques related to the extraction of IOFB. Material and Methods. A PubMed search on “Extraction of Intraocular Foreign Body,” “Timing for Surgery Intraocular Foreign Body,” and “Surgical Technique Intraocular Foreign Body” was made. Results. Potential advantages of immediate and delayed IOFB removal have been reported with different results. Several techniques to remove IOFB have been reported by different authors with good results. Conclusion. The most important factor at the time to perform IOFB extraction is the experience of the surgeon.

  5. Comparative study of 2 surgical techniques for castration of guinea pigs (Cavia porcellus).

    Science.gov (United States)

    Guilmette, Josée; Langlois, Isabelle; Hélie, Pierre; El Warrak, Alexander de Oliveira

    2015-10-01

    The objective of this study was to compare 2 surgical approaches (scrotal or abdominal) for castration of guinea pigs and to investigate post-operative infection rates with either technique. Forty-eight guinea pigs were castrated by scrotal or abdominal technique after being randomly assigned to 1 of 2 groups (n = 24). Individuals were either castrated by an experienced exotic animal surgeon (n = 12) or by an experienced small animal surgeon (n = 12). Surgical wounds were evaluated daily before euthanasia for histological evaluation 2 wks after surgery. Post-operative infection rate was significantly higher in the scrotal group than in the abdominal group, with a higher rate for the experienced small animal surgeon. Castration of guinea pigs with the abdominal technique is significantly faster and has a significantly lower post-operative infection rate than the scrotal technique.

  6. The Suprameatal Approach: A Safe Alternative Surgical Technique for Cochlear Implantation

    NARCIS (Netherlands)

    Postelmans, Job T. F.; Tange, Rinze A.; Stokroos, Robert J.; Grolman, Wilko

    2010-01-01

    Objective: To report on surgical complications arising post-operatively in 104 patients undergoing cochlear implantation surgery using the suprameatal approach (SMA). Second, to examine the advantages and disadvantages of the SMA technique compared with the classic mastoidectomy using the posterior

  7. A method of handing down surgical clipping technique for cerebral aneurysm

    International Nuclear Information System (INIS)

    Idei, Masaru; Yamane, Kanji; Okita, Shinji; Kumano, Kiyoshi; Nakae, Ryuta

    2009-01-01

    Meticulous clipping techniques are essential to obtain good results. Recently, the introduction of intravascular surgery for cerebral aneurysms has decreased the number of the direct clipping surgeries. And the increasing number of the lawsuits against doctors further discourages young surgeons from attempting clipping. As a result, young neurosurgeons, have less experience performing clipping. Therefore, we must learn clipping techniques from expert neurosurgeons under the limitation of having fewer opportunities to perform clipping surgery. In this paper, I present my experiences and discuss ways to obtain techniques for clipping surgery. I performed surgical clipping in 19 cases, 12 unruptured and 7 ruptured aneurysms, 7 males and 12 females aged from 36 to 79 years old (mean 61.9 years). Postoperatively, there were no symptomatic complications, but there were 2 asymptomatic infarctions that were revealed on CT scan. Intraoperative premature rupture occurred in 1 patient with a ruptured aneurysm. Techniques of manipulation with micro-forceps, suction and spatula are required for successful clipping. Off-the-job training of dissecting chicken wing arteries and rat abdominal aortas and vena cavas is useful. Moreover, actual experiences of surgical operations are essential. Surgical experiences raise the motivation of young neurosurgeons and encourage them to train more. We believe that this benign cycle contributes to meticulous surgical skills. (author)

  8. Evaluation of primary and secondary stability of titanium implants using different surgical techniques

    NARCIS (Netherlands)

    Tabassum, A.; Meijer, G.J.; Walboomers, X.F.; Jansen, J.A.

    2014-01-01

    OBJECTIVE: To investigate the influence of different surgical techniques on the primary and secondary implant stability using trabecular bone of goats as an implantation model. MATERIAL AND METHODS: In the iliac crest of eight goats, 48 cylindrical-screw-type implants with a diameter of 4.2 mm

  9. Outcome of Vaginoplasty in Male-to-Female Transgenders: A Systematic Review of Surgical Techniques

    NARCIS (Netherlands)

    Horbach, S.E.R.; Bouman, M.B.; Smit, J.M.; Özer, M.; Buncamper, M.E.; Mullender, M.G.

    2015-01-01

    Introduction: Gender reassignment surgery is the keystone of the treatment of transgender patients. For male-to-female transgenders, this involves the creation of a neovagina. Many surgical methods for vaginoplasty have been opted. The penile skin inversion technique is the method of choice for most

  10. Worldwide trends in surgical techniques in the treatment of esophageal and gastroesophageal junction cancer

    NARCIS (Netherlands)

    Haverkamp, L.; Seesing, M. F J; Ruurda, J. P.; Boone, J.; van Hillegersberg, R.

    The aim of this study was to evaluate the worldwide trends in surgical techniques for esophageal cancer surgery by comparing it to our survey from 2007. In addition, new questions were added for gastroesophageal junction (GEJ) cancer. An international survey on surgery of esophageal and GEJ cancer

  11. Testing of a new prototype surgical stapler that automates the rollover sleeve technique for venous anastomoses

    OpenAIRE

    PATRICIA B CARROLL; WERVISTON DEFARIA; CARLOS GANDIA; MARIANA BERHO; EVANGELOS MISIAKOS; ANDREAS G TZAKIS

    2006-01-01

    The creation of successful vascular anastomoses is of primary importance in many surgical fields. Numerous attempts to automate this process have been made. These techniques have slowly gained acceptance, but their use is still limited. This report details feasibility testing of a new prototype stapler that automates the rollover sleeve technique for venous vascular anastomoses. Male and female mongrel dogs (n=7) (25-32 kg) were used. A segment of the right (n=5) or left (n=2) iliac vein was ...

  12. Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection.

    Science.gov (United States)

    Helgeson, Melvin D; Kang, Daniel G; Lehman, Ronald A; Dmitriev, Anton E; Luhmann, Scott J

    2013-08-01

    There is currently no reliable technique for intraoperative assessment of pedicle screw fixation strength and optimal screw size. Several studies have evaluated pedicle screw insertional torque (IT) and its direct correlation with pullout strength. However, there is limited clinical application with pedicle screw IT as it must be measured during screw placement and rarely causes the spine surgeon to change screw size. To date, no study has evaluated tapping IT, which precedes screw insertion, and its ability to predict pedicle screw pullout strength. The objective of this study was to investigate tapping IT and its ability to predict pedicle screw pullout strength and optimal screw size. In vitro human cadaveric biomechanical analysis. Twenty fresh-frozen human cadaveric thoracic vertebral levels were prepared and dual-energy radiographic absorptiometry scanned for bone mineral density (BMD). All specimens were osteoporotic with a mean BMD of 0.60 ± 0.07 g/cm(2). Five specimens (n=10) were used to perform a pilot study, as there were no previously established values for optimal tapping IT. Each pedicle during the pilot study was measured using a digital caliper as well as computed tomography measurements, and the optimal screw size was determined to be equal to or the first size smaller than the pedicle diameter. The optimal tap size was then selected as the tap diameter 1 mm smaller than the optimal screw size. During optimal tap size insertion, all peak tapping IT values were found to be between 2 in-lbs and 3 in-lbs. Therefore, the threshold tapping IT value for optimal pedicle screw and tap size was determined to be 2.5 in-lbs, and a comparison tapping IT value of 1.5 in-lbs was selected. Next, 15 test specimens (n=30) were measured with digital calipers, probed, tapped, and instrumented using a paired comparison between the two threshold tapping IT values (Group 1: 1.5 in-lbs; Group 2: 2.5 in-lbs), randomly assigned to the left or right pedicle on each

  13. Techniques for Optimizing Surgical Scars, Part 2: Hypertrophic Scars and Keloids.

    Science.gov (United States)

    Potter, Kathryn; Konda, Sailesh; Ren, Vicky Zhen; Wang, Apphia Lihan; Srinivasan, Aditya; Chilukuri, Suneel

    2017-01-01

    Surgical management of benign or malignant cutaneous tumors may result in noticeable scars that are of great concern to patients, regardless of sex, age, or ethnicity. Techniques to optimize surgical scars are discussed in this three-part review. Part 2 focuses on scar revision for hypertrophic and keloids scars. Scar revision options for hypertrophic and keloid scars include corticosteroids, bleomycin, fluorouracil, verapamil, avotermin, hydrogel scaffold, nonablative fractional lasers, ablative and fractional ablative lasers, pulsed dye laser (PDL), flurandrenolide tape, imiquimod, onion extract, silicone, and scar massage.

  14. The first successful laparoscopic Whipple procedure at Hat Yai Hospital: surgical technique and a case report.

    Science.gov (United States)

    Khaimook, Araya; Borkird, Jumpot; Alapach, Sakda

    2010-09-01

    Whipple procedure is the most complex abdominal surgical procedure to treat periampullary carcinoma. With the benefit of minimally invasive approach, many institutes attempt to do Whipple procedure laparoscopically. However, only 146 cases of laparoscopic Whipple procedure have yet been reported in the literature worldwide between 1994 and 2008. The authors reported the first laparoscopic Whipple procedure at Hat Yai Hospital in December 2009. The patient was a 40-year-old, Thai-Muslim female, with the diagnosis of ampullary carcinoma. The operating time was 685 minutes. The patient was discharged on postoperative day 14 without serious complication. The surgical technique and postoperative progress of the patient were described.

  15. Useful surgical techniques for facial nerve preservation in tumorous intra-temporal lesions.

    Science.gov (United States)

    Kim, Jin; Moon, In Seok; Lee, Jong Dae; Shim, Dae Bo; Lee, Won-Sang

    2010-02-01

    The management of the facial nerve in tumorous temporal lesions is particularly challenging due to its complex anatomic location and potential postoperative complications, including permanent facial paralysis. The most important concern regarding surgical treatment of a tumorous temporal lesion is the inevitable facial paralysis caused by nerve injury during the tumor removal, especially in patients with minimal to no preoperative facial nerve dysfunction. We describe successful four cases in which various surgical techniques were developed for the preservation of the facial nerve in treatment of intratemporal tumorous lesions. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  16. Rehabilitation with 4 zygomatic implants with a new surgical protocol using ultrasonic technique.

    Science.gov (United States)

    Mozzati, Marco; Mortellaro, Carmen; Arata, Valentina; Gallesio, Giorgia; Previgliano, Valter

    2015-05-01

    When the residual bone crest cannot allow the placement of standard implants, the treatment for complete arch rehabilitation of severely atrophic maxillae can be performed with 4 zygomatic implants (ZIs) and immediate function with predictable results in terms of aesthetics, function, and comfort for the patient. However, even if ZIs' rehabilitations showed a good success rate, this surgery is difficult and need a skillful operator. Complications in this kind of rehabilitation are not uncommon; the main difficulties can be related to the reduced surgical visibility and instrument control in a critical anatomic area. All the surgical protocols described in the literature used drilling techniques. Furthermore, the use of ultrasonic instruments in implant surgery compared with drilling instruments have shown advantages in many aspects of surgical procedures, tissues management, enhancement of control, surgical visualization, and healing. The aim of this study was to report on the preliminary experience using ultrasound technique for ZIs surgery in terms of safety and technical improvement. Ten consecutive patients with severely atrophic maxilla have been treated with 4 ZIs and immediate complete arch acrylic resin provisional prostheses. The patients were followed up from 30 to 32 months evaluating implant success, prosthetic success, and patient satisfaction with a questionnaire. No implants were lost during the study period, with a 100% implant and prosthetic success rate. Within the limitations of this preliminary study, these data indicate that ultrasonic implant site preparation for ZIs can be a good alternative to the drilling technique and an improvement for the surgeon.

  17. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    Science.gov (United States)

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  18. Clinical results of free-hand pedicle screw placement by the palpation of lateral wall of pedicle (PLP) method for scoliosis surgery

    International Nuclear Information System (INIS)

    Oyama, Motohiko; Shimizu, Takachika; Fueki, Keisuke; Ino, Masatake; Toda, Naofumi; Tanouti, Tetu; Tatara, Yasunori; Manabe, Nodoka

    2011-01-01

    The purpose of this study was to evaluate the accuracy of thoracic pedicle screw (TPS) placement by the palpation of the lateral wall of the pedicle (PLP) method. The subjects of this study were 45 scoliosis patients. The accuracy of TPS placement was evaluated by postoperative CT. Of the 348 TPSs inserted, 26 (7.5%) breached the pedicle wall. Of the 26 misplaced screws, 20 were inserted on the wrong trajectory, and 6 were inserted at the wrong insertion point. The preoperative major Cobb angle averaged 70.4 deg in the group with pedicle perforation by the TPS, and 54.1 deg in the group with correct placement of the TPS (p=0.006). No intra- or post-operative complications developed as a result of the pedicle perforation. The PLP method is useful in deciding on the correct insertion point, but it is of no assistance in inserting screws along the correct trajectory. This, it will be necessary to improve the technique of determining the correct trajectory for the TPS. (author)

  19. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    Energy Technology Data Exchange (ETDEWEB)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-10-01

    Two different radioactive microspheres ( U Ce and UWSc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures.

  20. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    International Nuclear Information System (INIS)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-01-01

    Two different radioactive microspheres ( 141 Ce and 46 Sc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures

  1. Novel free-hand T1 pedicle screw method: Review of 44 consecutive cases

    Directory of Open Access Journals (Sweden)

    Mark A Rivkin

    2014-01-01

    Full Text Available Summary of Background Data: Multilevel posterior cervical instrumented fusions are becoming more prevalent in current practice. Biomechanical characteristics of the cervicothoracic junction may necessitate extending the construct to upper thoracic segments. However, fixation in upper thoracic spine can be technically demanding owing to transitional anatomy while suboptimal placement facilitates vascular and neurologic complications. Thoracic instrumentation methods include free-hand, fluoroscopic guidance, and CT-based image guidance. However, fluoroscopy of upper thoracic spine is challenging secondary to vertebral geometry and patient positioning, while image-guided systems present substantial financial commitment and are not readily available at most centers. Additionally, imaging modalities increase radiation exposure to the patient and surgeon while potentially lengthening surgical time. Materials and Methods: Retrospective review of 44 consecutive patients undergoing a cervicothoracic fusion by a single surgeon using the novel free-hand T1 pedicle screw technique between June 2009 and November 2012. A starting point medial and cephalad to classic entry as well as new trajectory were utilized. No imaging modalities were employed during screw insertion. Postoperative CT scans were obtained on day 1. Screw accuracy was independently evaluated according to the Heary classification. Results: In total, 87 pedicle screws placed were at T1. Grade 1 placement occurred in 72 (82.8% screws, Grade 2 in 4 (4.6% screws and Grade 3 in 9 (10.3% screws. All Grade 2 and 3 breaches were <2 mm except one Grade 3 screw breaching 2-4 mm laterally. Only two screws (2.3% were noted to be Grade 4, both breaching medially by less than 2 mm. No new neurological deficits or returns to operating room took place postoperatively. Conclusions: This modification of the traditional starting point and trajectory at T1 is safe and effective. It attenuates additional bone

  2. One stage reconstruction of the floor of the mouth with a subcutaneous pedicled nasolabial flap

    International Nuclear Information System (INIS)

    El-Marakby, H.H.; Fouad, F.A.; Ali, H.H.

    2012-01-01

    Background: Nasolabial flaps have been recognised as versatile flaps for a variety of defects in the face, nose, lip and the oral cavity. Random pattern inferiorly based nasolabial flaps (NLF) have been utilised for covering small defects on the anterior floor of the mouth, but usually require a second stage procedure to divide the flap base. A subcutaneous pedicled inferiorly based nasolabial flap can provide a one stage repair of moderate sized defects of the floor of the mouth after de epithelialisation of the base of the flap. Aim: To evaluate the feasibility of a single stage reconstruction of intermediate sized defects in the oral cavity with an inferiorly based pedicled NLF. The study includes the indications of use of the flap, flap design, technique, and the complications rate. The incidence of secondary procedures and the final functional and the aesthetic results will also be evaluated. Materials and methods: A group of 20 patients presented with (T1-2) squamous cell carcinoma of the oral cavity have been treated at the Department of Surgery, National Cancer Institute, Cairo; in the period between January 2008 and September 2010. The pathology was confirmed with an incision biopsy and all metastatic work were carried out confirming that all patients were free from distant metastasis at presentation. Preoperative assessment also included assessment of the stage of the disease, the flap design and patient fitness for general anaesthesia. All patients underwent surgical excision combined with reconstruction of the defect with a subcutaneous inferiorly based pedicled NLF. The proximal part of the flap was routinely de epithelialised before it has been tunnelled through the cheek so a one stage procedure could only be required. Results: The mean age of the patients was 62.3±6 years, range (52-69 years). All patients were diagnosed with squamous cell carcinoma. The anterior floor of the mouth constituted 40% of the defects, the lateral floor of the mouth 20

  3. Priority of surgical treatment techniques of full cartilage defects of knee joint

    Directory of Open Access Journals (Sweden)

    Андрій Вікторович Літовченко

    2015-10-01

    Full Text Available Aim. Surgical treatment of chondromalacia of knee joint cartilage is an actual problem of the modern orthopedics because the means of conservative therapy can be realized at an initial stage only and almost exhausted at the further ones. Imperfections of palliative surgical techniques are the short-term clinical effect and pathogenetic baselessness because surgical procedure is not directed on reparation of cartilaginous tissue. For today there are a lot of transplantation techniques that are used for biological renewal of articular surface with formation of hyaline or at least hyaline-like cartilage. The deep forage of cartilage defect bottom to the medullary canal is a perspective and priority technique.Methods. The results of treatment of 61 patients with chondromalacia of knee joint of 3-4 degree according to R. Outerbridge are the base of the work. 20 patients of every group underwent microfracturization of cartilage defect bottom and subchondral forage of defect zone. 21 patients underwent the deep forage of defect zone of knee joint according to an offered technique.Result. The results of treatment with microfracturization, subchondral forage and deep forage of defect zone indicate the more strong clinical effect especially in the last clinical group where good and satisfactory results ratios in the term of observation 18 and 24 month remain stable.Conclusions. Deep forage of cartilage defects zone is the most adequate reparative technique of the surgical treatment of local knee joint cartilage defects. Owing to this procedure the number of cells of reparative chondrogenesis predecessors is realized

  4. [Multiple colonic anastomoses in the surgical treatment of short bowel syndrome. A new technique].

    Science.gov (United States)

    Robledo-Ogazón, Felipe; Becerril-Martínez, Guillermo; Hernández-Saldaña, Víctor; Zavala-Aznar, Marí Luisa; Bojalil-Durán, Luis

    2008-01-01

    Some surgical pathologies eventually require intestinal resection. This may lead to an extended procedure such as leaving 30 cm of proximal jejunum and left and sigmoid colon. One of the most important consequences of this type of resection is "intestinal failure" or short bowel syndrome. This complex syndrome leads to different metabolic and water and acid/base imbalances, as well as nutritional and immunological challenges along with the problem accompanying an abdomen subjected to many surgical procedures and high mortality. Many surgical techniques have been developed to improve quality of life of patients. We designed a non-transplant surgical approach and performed the procedure on two patients with postoperative short bowel syndrome with work can be performed by a large number of surgeons. The procedure has a low morbimortality rate and offers the opportunity for better control of metabolic and acid/base balance, intestinal transit and proper nutrition. We consider that this technique offers a new alternative for the complex management required by patients with short bowel syndrome and facilitates their long-term nutritional control.

  5. A novel surgical method for total nail ablation: Use of triple flap technique

    Directory of Open Access Journals (Sweden)

    Berna Aksoy

    2017-11-01

    Full Text Available Total nail ablation for the treatment of onychodystrophies can be performed by using chemicals, surgical resection or laser ablation of nail matrix. A female patient with bilateral severe onychodystrophy as a result of inadvertent previous nail surgeries was treated surgically. Proximal complete nail matrix resection and distal 10 mm wide transverse strip partial nail bed resection were performed. A 5 mm wide transverse strip of nail bed was left intact proximally. Proximal nail matrix defect was closed by using the skin of proximal nail fold. The distal nail bed defect was reconstructed by using triple flap technique which was composed of a main central advancement flap containing ventral toe skin and two side flaps containing nail fold skin. The patient healed without any problem and her nail problem was treated successfully. The cosmetic appearance of her first toes was acceptable. Surgical nail ablation followed by volar skin coverage of dorsal surface of the distal phalanx bone by using triple flap technique is an effective surgical treatment method for the correction of advanced nail plate deformities requiring total nail ablation. 

  6. The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?

    Science.gov (United States)

    Paik, Haines; Kang, Daniel G; Lehman, Ronald A; Gaume, Rachel E; Ambati, Divya V; Dmitriev, Anton E

    2013-11-01

    Rod contouring is frequently required to allow for appropriate alignment of pedicle screw-rod constructs. When residual mismatch is still present, a rod persuasion device is often used to achieve further rod reduction. Despite its popularity and widespread use, the biomechanical consequences of this technique have not been evaluated. To evaluate the biomechanical fixation strength of pedicle screws after attempted reduction of a rod-pedicle screw mismatch using a rod persuasion device. Fifteen 3-level, human cadaveric thoracic specimens were prepared and scanned for bone mineral density. Osteoporotic (n=6) and normal (n=9) specimens were instrumented with 5.0-mm-diameter pedicle screws; for each pair of comparison level tested, the bilateral screws were equal in length, and the screw length was determined by the thoracic level and size of the vertebra (35 to 45 mm). Titanium 5.5-mm rods were contoured and secured to the pedicle screws at the proximal and distal levels. For the middle segment, the rod on the right side was intentionally contoured to create a 5-mm residual gap between the inner bushing of the pedicle screw and the rod. A rod persuasion device was then used to engage the setscrew. The left side served as a control with perfect screw/rod alignment. After 30 minutes, constructs were disassembled and vertebrae individually potted. The implants were pulled in-line with the screw axis with peak pullout strength (POS) measured in Newton (N). For the proximal and distal segments, pedicle screws on the right side were taken out and reinserted through the same trajectory to simulate screw depth adjustment as an alternative to rod reduction. Pedicle screws reduced to the rod generated a 48% lower mean POS (495±379 N) relative to the controls (954±237 N) (p.05). In circumstances where a rod is not fully seated within the pedicle screw, the use of a rod persuasion device decreases the overall POS and work energy to failure of the screw or results in outright

  7. Minimally invasive corticotomy in orthodontics: a new technique using a CAD/CAM surgical template.

    Science.gov (United States)

    Cassetta, M; Pandolfi, S; Giansanti, M

    2015-07-01

    Accelerating orthodontic tooth movement is a topical issue. Despite the different techniques described in the literature, the corticotomy is the only effective and safe means of accelerating orthodontic tooth movement. Although effective, the corticotomy presents significant postoperative discomfort. The aggressive nature of these particular methods, related to the elevation of mucoperiosteal flaps and to the length of the surgery, has resulted in reluctance to proceed with this technique among both patients and the dental community. To overcome the disadvantages of the corticotomy, this technical note describes an innovative, minimally invasive, flapless procedure combining piezoelectric surgical cortical micro-incisions with the use of a 3D Printed CAD/CAM surgical guide. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Postoperative Radiculopathy Caused by a Retained Fractured Pedicle Cannulation Probe and Its Mechanism of Extraction.

    Science.gov (United States)

    Yuk, Frank; Steinberger, Jeremy; Skovrlj, Branko; Mascitelli, Justin; Cho, Samuel K; Caridi, John M

    2017-11-01

    Spine surgery relies heavily on technology and surgical instrumentation. Improperly used instrumentation can be detrimental to the patient. Despite multiple checkpoints to ensure that foreign bodies are not retained in surgery, numerous case reports have described retained foreign bodies; however, none of these cases involve retained instrumentation after open spine surgery. Of the retained objects, 4 were sponges and one was a Jamshidi needle fragment. Although smaller objects are more commonly the culprits, surgical instruments can break off, remain stuck, and cause clinical sequelae. This case presents a retained fractured pedicle finder as the cause of right L5 radiculopathy. To our knowledge, this report is the first to describe an instrumentation-associated postoperative radiculopathy. Because of the strength with which the object was impacted, its extraction proved difficult. The technique of removal using a mallet and osteotome in 4 directions to loosen its hold in the vertebral body. Attempts and eventual successful removal are described. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Virtual surgery simulation versus traditional approaches in training of residents in cervical pedicle screw placement.

    Science.gov (United States)

    Hou, Yang; Shi, Jiangang; Lin, Yanping; Chen, Huajiang; Yuan, Wen

    2018-06-01

    The cervical screw placement is one of the most difficult procedures in spine surgery, which often needs a long period of repeated practices and could cause screw placement-related complications. We performed this cadaver study to investigate the effectiveness of virtual surgical training system (VSTS) on cervical pedicle screw instrumentation for residents. A total of ten novice residents were randomly assigned to two groups: the simulation training (ST) group (n = 5) and control group (n = 5). The ST group received a surgical training of cervical pedicle screw placement on VSTS and the control group was given an introductory teaching session before cadaver test. Ten fresh adult spine specimens including 6 males and 4 females were collected, and were randomly allocated to the two groups. The bilateral C3-C6 pedicle screw instrumentation was performed in the specimens of the two groups, respectively. After instrumentation, screw positions of the two groups were evaluated by image examinations. There was significantly statistical difference in screw penetration rates between the ST (10%) and control group (62.5%, P VSTS as an advanced training tool exhibited promising effects on improving performance of novice residents in cervical pedicle screw placement compared with the traditional teaching methods.

  10. Reversible hydronephrosis in the rat: a new surgical technique assessed by radioisotopic measurements

    International Nuclear Information System (INIS)

    Flam, T.; Venot, A.; Bariety, J.

    1984-01-01

    A new technique for experimental reversible hydronephrosis in the rat was developed. A noninvasive radioisotopic investigation, using Tc-99m dimercaptosuccinic acid, permitted sequential assessment of the separate renal function at different stages of the study. After 1 week of unilateral ureteral obstruction, reversibility was obtained by the removal of the obstructive device. Ten days after the obstruction release, the ipsilateral kidney had returned to 71 per cent of its preligation uptake value. Histological findings demonstrated the reversibility of the surgical obstruction

  11. Ontogeny of a surgical technique: Robotic kidney transplantation with regional hypothermia.

    Science.gov (United States)

    Sood, Akshay; McCulloch, Peter; Dahm, Philipp; Ahlawat, Rajesh; Jeong, Wooju; Bhandari, Mahendra; Menon, Mani

    2016-01-01

    Innovation is a hallmark of surgical practice. It is generally accepted that a new procedure will undergo technical changes during its evolution; however, quantitative accounts of the process are limited. Multiple groups, including our own, have recently described a minimally-invasive approach to conventional kidney transplantation (KT) operation. Unique to our experience is a structured development of the technique within the confines of a safe surgical innovation framework - the IDEAL framework (idea, development, exploration, assessment, long-term monitoring; stages 0-4). We here provide a first-hand narrative of the progress of robotic KT operation from preclinical trial to clinical application. Overall, 54 patients underwent robotic KT with regional hypothermia successfully. Major technical changes including selection of optimal patient position (flank vs. lithotomy), robotic instrumentation, vascular occlusion method (bulldog vs. tourniquet) and suture material (prolene vs. GoreTex) occurred early during the procedure development (IDEAL stage 0, preclinical). Minor technical changes such as utilization of the aortic punch for arteriotomy (case 3), use of barbed suture during ureteroneocystostomy (case 6) and extraperitonealization of the graft kidney (case 6) that increased the efficiency and safety of the procedure continued throughout procedure development (IDEAL stages 1-2, clinical stages). We demonstrate that a surgical technique evolves continually; although, the majority of technical alterations occur early in the life-cycle of the procedure. Development of a new technique within the confines a structured surgical innovation framework allows for evidence based progression of the technique and may minimize the risk of harm to the patient. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  12. A new surgical technique for concealed penis using an advanced musculocutaneous scrotal flap.

    Science.gov (United States)

    Han, Dong-Seok; Jang, Hoon; Youn, Chang-Shik; Yuk, Seung-Mo

    2015-06-19

    Until recently, no single, universally accepted surgical method has existed for all types of concealed penis repairs. We describe a new surgical technique for repairing concealed penis by using an advanced musculocutaneous scrotal flap. From January 2010 to June 2014, we evaluated 12 patients (12-40 years old) with concealed penises who were surgically treated with an advanced musculocutaneous scrotal flap technique after degloving through a ventral approach. All the patients were scheduled for regular follow-up at 6, 12, and 24 weeks postoperatively. The satisfaction grade for penile size, morphology, and voiding status were evaluated using a questionnaire preoperatively and at all of the follow-ups. Information regarding complications was obtained during the postoperative hospital stay and at all follow-ups. The patients' satisfaction grades, which included the penile size, morphology, and voiding status, improved postoperatively compared to those preoperatively. All patients had penile lymphedema postoperatively; however, this disappeared within 6 weeks. There were no complications such as skin necrosis and contracture, voiding difficulty, or erectile dysfunction. Our advanced musculocutaneous scrotal flap technique for concealed penis repair is technically easy and safe. In addition, it provides a good cosmetic appearance, functional outcomes and excellent postoperative satisfaction grades. Lastly, it seems applicable in any type of concealed penis, including cases in which the ventral skin defect is difficult to cover.

  13. The Omental Pedicle Flap in Dogs Revised and Refined: A Cadaver Study.

    Science.gov (United States)

    Doom, Marjan; Cornillie, Pieter; Simoens, Paul; Huyghe, Stephanie; de Rooster, Hilde

    2016-08-01

    To expand current knowledge on the canine omental vasculature and refine the existing lengthening technique of the canine omentum. Ex vivo study. Canine cadavers (n=20). In 10 canine cadavers the omental arteries were mapped using intravascular latex injection and these results were used to create an omental pedicle flap based on the splenic artery in 10 additional cadavers. The operating range of the flap was recorded with particular attention to the main regions of interest for omental transposition in dogs (axillary and inguinal regions). The superficial and deep omental leaves were each predominantly supplied by a left and a right marginal omental artery that anastomosed near the caudal omental border into a superficial and a deep omental arch, respectively. Anastomoses between arteries of the superficial and the deep omental leaves were weak and inconsistent, except for 1 anastomosis that was found in 8 of 10 dogs. By transposing the intact omentum, the right axilla could be reached in 3 dogs, both axillae in 1 dog, and both groins in all cadavers. In all cases, the omental pedicle reached to and beyond the axillary and inguinal regions. By unfolding the pedicle leaves, the width of the pedicle tip could be doubled. When lengthening the omentum is necessary to reach extra-abdominal structures, the omental pedicle flap based on the splenic artery appears to preserve the omental vascular supply. These observations warrant further clinical trials to evaluate this new omtental flap technique in vivo. © Copyright 2016 by The American College of Veterinary Surgeons.

  14. Combining Breast Reduction Techniques to Treat Gigantomastia in Ghana

    Directory of Open Access Journals (Sweden)

    Melody F. Scheefer, MD

    2018-02-01

    Full Text Available Summary:. In this presentation of 2 consecutive cases of symptomatic juvenile breast hypertrophy in Ghana, we review the patient presentation, workup, and discuss outcomes following a combined technique of inferior pedicle stump with free nipple graft reduction mammoplasty. Surgical goals for treatment of gigantomastia were 2-fold: to resect adequate tissue to obtain symptomatic relief with improved quality of life, while avoiding a flat, boxy-appearing breast shape.

  15. Use of the Composite Pedicled Pectoralis Minor Flap after Resection of Soft Tissue Sarcoma in Reconstruction of the Glenohumeral Joint

    Directory of Open Access Journals (Sweden)

    Michiel A. J. van de Sande

    2014-01-01

    Full Text Available The surgical repair of an extensive anterior glenohumeral soft tissue defect is complicated by glenohumeral instability and subsequent significant functional deficit. This surgical note offers a relatively simple reconstruction of the anterior capsule and subscapularis muscle using a pectoralis minor pedicle flap. This reconstruction is supplemented with functional reconstruction of the anterior glenohumeral joint. A conventional deltopectoral approach is utilized and pectoralis minor is freed from its coracoid insertion, released, and mobilized without compromising the pedicle entering from the dorsum and inferior one-third of the muscle. The mobilized pectoralis minor vascular pedicle has sufficient length for the pectoralis minor to be transferred to provide coverage of the anterior shoulder joint even in full external rotation, providing anterior stability. To further improve glenohumeral stability and shoulder function, the pectoralis major muscle can be split with the clavicular part reinserted lateral to the bicipital groove onto the lesser tuberosity replacing subscapularis function while stabilising the glenohumeral joint.

  16. Choice of a General Anesthesia Technique in the Surgical Treatment of Postinfarct Left Ventricular Aneurysms

    Directory of Open Access Journals (Sweden)

    N. A. Karpun

    2005-01-01

    Full Text Available Objective. To choose the optimum technique of general anesthesia in the surgical treatment of patients with postinfarct left ventricular aneurysms (PLVA.Materials and methods. Fifty-four patients operated on for PLVA were examined. They were divided into 4 groups according to the basic technique of general anesthesia: 1 intravenous anesthesia based on propofol and fentanyl; 2 inhalation sevoflurane anesthesia with fentanyl enhancement of the analgesic component; 3 inhalation isoflurane anesthesia with fentanyl enhancement of the analgesic component; 4 general anesthesia in combination with epidural blockade. Central hemodynamics was investigated by the thermodilution technique and the perioperative period was also studied.Results and discussion. None of the general anesthesia techniques affected the development of perioperative complications. However, with decreased myocardial reserves, high thoracic epidural anesthesia should be applied with caution as it causes a significant desympathization, which may lead to impairments of the autoregulatory mechanisms of coronary blood flow and aggravate existing contractile disorders. Intravenous and inhalation anesthesia techniques provide a fair hemodynamic stability at all stages of surgical treatment. Inhalation anesthesia has a number of advantages: less cost and the possibility of rapid activation of patients in the early postoperative period.

  17. [Management of spinal metastasis by minimal invasive surgery technique: Surgical principles, indications: A literature review].

    Science.gov (United States)

    Toquart, A; Graillon, T; Mansouri, N; Adetchessi, T; Blondel, B; Fuentes, S

    2016-06-01

    Spinal metastasis are getting more frequent. This raises the question of pain and neurological complications, which worsen the functional and survival prognosis of this oncological population patients. The surgical treatment must be the most complete as possible: to decompress and stabilize without delaying the management of the oncological disease. Minimal invasive surgery techniques are by definition, less harmful on musculocutaneous plan than opened ones, with a comparable efficiency demonstrated in degenerative and traumatic surgery. So they seem to be applicable and appropriate to this patient population. We detailed different minimal invasive techniques proposed in the management of spinal metastasis. For this, we used our experience developed in degenerative and traumatic pathologies, and we also referred to many authors, establishing a literature review thanks to Pubmed, Embase. Thirty eight articles were selected and allowed us to describe different techniques: percutaneous methods such as vertebro-/kyphoplasty and osteosynthesis, as well as mini-opened surgery, through a posterior or anterior way. We propose a surgical approach using these minimal invasive techniques, first according to the predominant symptom (pain or neurologic failure), then characteristics of the lesions (number, topography, type…) and the deformity degree. Whatever the technique, the main goal is to stabilize and decompress, in order to maintain a good quality of life for these fragile patients, without delaying the medical management of the oncological disease. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Use of the 3D surgical modelling technique with open-source software for mandibular fibula free flap reconstruction and its surgical guides.

    Science.gov (United States)

    Ganry, L; Hersant, B; Quilichini, J; Leyder, P; Meningaud, J P

    2017-06-01

    Tridimensional (3D) surgical modelling is a necessary step to create 3D-printed surgical tools, and expensive professional software is generally needed. Open-source software are functional, reliable, updated, may be downloaded for free and used to produce 3D models. Few surgical teams have used free solutions for mastering 3D surgical modelling for reconstructive surgery with osseous free flaps. We described an Open-source software 3D surgical modelling protocol to perform a fast and nearly free mandibular reconstruction with microvascular fibula free flap and its surgical guides, with no need for engineering support. Four successive specialised Open-source software were used to perform our 3D modelling: OsiriX ® , Meshlab ® , Netfabb ® and Blender ® . Digital Imaging and Communications in Medicine (DICOM) data on patient skull and fibula, obtained with a computerised tomography (CT) scan, were needed. The 3D modelling of the reconstructed mandible and its surgical guides were created. This new strategy may improve surgical management in Oral and Craniomaxillofacial surgery. Further clinical studies are needed to demonstrate the feasibility, reproducibility, transfer of know how and benefits of this technique. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Impact of robotic technique and surgical volume on the cost of radical prostatectomy.

    Science.gov (United States)

    Hyams, Elias S; Mullins, Jeffrey K; Pierorazio, Phillip M; Partin, Alan W; Allaf, Mohamad E; Matlaga, Brian R

    2013-03-01

    Our present understanding of the effect of robotic surgery and surgical volume on the cost of radical prostatectomy (RP) is limited. Given the increasing pressures placed on healthcare resource utilization, such determinations of healthcare value are becoming increasingly important. Therefore, we performed a study to define the effect of robotic technology and surgical volume on the cost of RP. The state of Maryland mandates that all acute-care hospitals report encounter-level and hospital discharge data to the Health Service Cost Review Commission (HSCRC). The HSCRC was queried for men undergoing RP between 2008 and 2011 (the period during which robot-assisted laparoscopic radical prostatectomy [RALRP] was coded separately). High-volume hospitals were defined as >60 cases per year, and high-volume surgeons were defined as >40 cases per year. Multivariate regression analysis was performed to evaluate whether robotic technique and high surgical volume impacted the cost of RP. There were 1499 patients who underwent RALRP and 2565 who underwent radical retropubic prostatectomy (RRP) during the study period. The total cost for RALRP was higher than for RRP ($14,000 vs 10,100; Probotic surgery has come to dominate the healthcare marketplace, strategies to increase the role of high-volume providers may be needed to improve the cost-effectiveness of prostate cancer surgical therapy.

  20. Surgical techniques for the treatment of ankyloglossia in children: a case series

    Directory of Open Access Journals (Sweden)

    Marina Azevedo JUNQUEIRA

    2014-06-01

    Full Text Available This paper reports a series of clinical cases of ankyloglossia in children, which were approached by different techniques: frenotomy and frenectomy with the use of one hemostat, two hemostats, a groove director or laser. Information on the indications, contraindications, advantages and disadvantages of the techniques was also presented. Children diagnosed with ankyloglossia were subjected to different surgical procedures. The choice of the techniques was based on the age of the patient, length of the frenulum and availability of the instruments and equipment. All the techniques presented are successful for the treatment of ankyloglossia and require a skilled professional. Laser may be considered a simple and safe alternative for children while reducing the amount of local anesthetics needed, the bleeding and the chances of infection, swelling and discomfort.

  1. Frequency of lingual nerve injury in mandibular third molar extraction: A comparison of two surgical techniques

    International Nuclear Information System (INIS)

    Shad, S.; Abbasi, M.M.

    2015-01-01

    Background: Surgical removal of impacted mandibular third molar is associated with a number of complications including postoperative bleeding, dry socket, postoperative infection, and injury to regional nerves. Lingual nerve damage is one of the main complications. To prevent this complication different techniques had been used. Lingual flap reflection is one of these procedures in which lingual soft tissue is reflected and retracted deliberately, the nerve is identified and is kept out of the surgical field. The objective of this study was to evaluate a surgical technique for third molar removal which is associated with minimum frequency of lingual nerve damage. Method: A randomized controlled trial was performed. A total of 380 patients with impacted mandibular third molars were included in this study. Each patient was allotted randomly by blocked randomization to group A where procedure was performed by reflection and retraction of lingual flap in addition to buccal flap and group B where procedure was performed by retraction of buccal flap only. Results: Lingual nerve damage occurred in 8.94 percentage in Group A in which lingual flap retraction was performed but damage was reversible. In group B, 2.63 percentage lingual nerve damage was observed and nature of damage was permanent. The difference was statistically significant (p=0.008). Conclusions: Lingual flap retraction poses 3.4 times increased risk of lingual nerve damage during extraction of mandibular third molar when lingual flap is retracted but the nature of damage is reversible. (author)

  2. Multiaxial pedicle screw designs: static and dynamic mechanical testing.

    Science.gov (United States)

    Stanford, Ralph Edward; Loefler, Andreas Herman; Stanford, Philip Mark; Walsh, William R

    2004-02-15

    Randomized investigation of multiaxial pedicle screw mechanical properties. Measure static yield and ultimate strengths, yield stiffness, and fatigue resistance according to an established model. Compare these measured properties with expected loads in vivo. Multiaxial pedicle screws provide surgical versatility, but the complexity of their design may reduce their strength and fatigue resistance. There is no published data on the mechanical properties of such screws. Screws were assembled according to a vertebrectomy model for destructive mechanical testing. Groups of five assemblies were tested in static tension and compression and subject to three cyclical loads. Modes of failure, yield, and ultimate strength, yield stiffness, and cycles to failure were determined for six designs of screw. Static compression yield loads ranged from 217.1 to 388.0 N and yield stiffness from 23.7 to 38.0 N/mm. Cycles to failure ranged from 42 x 10(3) to 4,719 x 10(3) at 75% of static ultimate load. There were significant differences between designs in all modes of testing. Failure occurred at the multiaxial link in static and cyclical compression. Bending yield strengths just exceeded loads expected in vivo. Multiaxial designs had lower static bending yield strength than fixed screw designs. Five out of six multiaxial screw designs achieved one million cycles at 200 N in compression bending. "Ball-in-cup" multiaxial locking mechanisms were vulnerable to fatigue failure. Smooth surfaces and thicker material appeared to be protective against fatigue failure.

  3. Comparative Analysis of Interval, Skipped, and Key-vertebral Pedicle Screw Strategies for Correction in Patients With Lenke Type 1 Adolescent Idiopathic Scoliosis.

    Science.gov (United States)

    Wang, Fei; Xu, Xi-Ming; Lu, Yanghu; Wei, Xian-Zhao; Zhu, Xiao-Dong; Li, Ming

    2016-03-01

    Pedicle screw constructs have become the mainstay for surgical correction in patients with spinal deformities. To reduce or avoid the risk of pedicle screw-based complications and to decrease the costs associated with pedicle screw instrumentation, some authors have introduced interval, skipped, and key-vertebral pedicle screw strategies for correction. However, there have been no comparisons of outcomes among these 3 pedicle screw-placement strategies.The aim of this study was to compare the correlative clinical outcomes of posterior correction and fusion with pedicle screw fixation using these 3 surgical strategies.Fifty-six consecutive patients with Lenke type 1 adolescent idiopathic scoliosis were included in this study. Twenty patients were treated with the interval pedicle screw strategy (IPSS), 20 with the skipped pedicle screw strategy (SPSS), and 16 with the key-vertebral pedicle screw strategy (KVPSS). Coronal and sagittal radiographs were analyzed before surgery, at 1 week after surgery, and at the last follow-up after surgery.There were no significant differences among the 3 groups regarding preoperative radiographic parameters. No significant difference was found between the IPSS and SPSS groups in correction of the main thoracic curve (70.8% vs 70.0%; P = 0.524). However, there were statistically significant differences between the IPSS and KVPSS groups (70.8% vs 64.9%) and between the SPSS and KVPSS groups (70.0% vs 64.9%) in correction of the main thoracic curve (P SPSS group was significantly higher than those in the IPSS (P SPSS and KVPSS groups (P SPSS, it can achieve a satisfactory clinical outcome and is more cost-effective.

  4. Surgical techniques and curative effect of carotid endarterectomy for carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Min HAN

    2014-02-01

    Full Text Available Objective To investigate the surgical techniques of carotid endarterectomy (CEA for treating carotid artery stenosis, in order to improve the surgical efficacy and reduce intraoperative adverse events and complications after operation. Methods Retrospective analysis was carried out on surgical data of 53 cases who were performed CEA from October 2010 to October 2013 in Department of Neurosurgery in Tianjin Huanhu Hospital. There were 39 males and 14 females, aged from 40 to 78 years old and mean age (60.34 ± 8.92 years old; the course of disease was from 2 d to 4 years. Twenty-six cases were diagnosed as right carotid stenosis, 15 cases left carotid stenosis and 12 cases double-sided carotid stenosis. Among all of those cases, 35 cases were diagnosed as moderate stenosis (30%-69%, 16 cases severe stenosis (70%-99% , and 2 cases complete occlusion. Results Among 53 patients, 50 patients underwent CEA; 2 cases underwent CEA and aneurysm clipping; one case underwent stent removal surgery and CEA because restenosis was found after carotid artery stenting (CAS. Postoperative neck CTA and fMRI showed good morphology of carotid artery, fluent blood flow and improved cerebral perfusion after operation. All of those patients were followed up for 3 to 24 months. One case died of myocardial infarction; 2 cases appeared skin numbness on the operating side of the neck, and the symptom disappeared 3 months later; one case appeared hoarseness after operation; 3 cases experienced mild transient ischemic attack (TIA and the symptom disappeared 2 months later. No case of stroke was found. Conclusions CEA is a safe and effective surgical approach to treat carotid stenosis. Correct and reasonable choices of the surgical indications and skilled surgical technique are the key to ensure the success of operation and to improve efficacy of the therapy. doi:10.3969/j.issn.1672-6731.2014.02.006Video: http://www.cjcnn.org/index.php/cjcnn/pages/view/v14n2a6

  5. Congenital completely buried penis in boys: anatomical basis and surgical technique.

    Science.gov (United States)

    Liu, Xing; He, Da-wei; Hua, Yi; Zhang, De-ying; Wei, Guang-hui

    2013-07-01

    WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: Surgical correction of the congenital completely buried penis (CCBP) is a difficult challenge and there is no unanimous consensus about the surgical 'gold standard' and patient eligibility for surgery. In the present study, dysgenetic fundiform ligaments were found to be attached to the distal or middle shaft of the penis. This abnormality can be successfully corrected by releasing the fundiform ligament and mobilising the scrotal skin to cover the length of the penile shaft. The study shows that the paucity and traction of the penile skin and an abnormal fundiform ligament are important anatomical defects in CCBP. Dorsal curve and severe shortage of penile skin in erectile conditions are the main indications for surgical correction. To present our experience of anatomical findings for congenital completely buried penis (CCBP), which has no unanimous consensus regarding the 'gold standard' for surgical correction and patient eligibility, by providing our surgical technique and illustrations. Between February 2006 and February 2011, 22 children with a median (range) age of 4.2 (2.5-5.8) years, with CCBP underwent surgical correction by one surgeon. Toilet training and photographs of morning erections by parents were advised before surgery. The abnormal anatomical structure of buried penis during the operation was observed. The technique consisted of the release of the fundiform ligament, fixation of the subcutaneous penile skin at the base of the degloved penis, penoscrotal Z-plasty and mobilisation of the penile and scrotal skin to cover the penile shaft. In reflex erectile conditions, CCBP presents varying degrees of dorsal curve and shortage of penile skin. Dysgenetic fundiform ligaments were found to be attached to the distal or middle shaft of the penis in all patients. All wounds healed well and the cosmetic outcome was good at 6-month follow-up after the repair. The appearance of the dorsal curve in

  6. Intestinal vaginoplasty revisited: a review of surgical techniques, complications, and sexual function.

    Science.gov (United States)

    Bouman, Mark-Bram; van Zeijl, Michiel C T; Buncamper, Marlon E; Meijerink, Wilhelmus J H J; van Bodegraven, Ad A; Mullender, Margriet G

    2014-07-01

    Vaginal (re)construction is essential for the psychological well-being of biological women with a dysfunctional vagina and male-to-female transgender women. However, the preferred method for vagina (re)construction with respect to functional as well as aesthetic outcomes is debated. Regarding intestinal vaginoplasty, despite the asserted advantages, the need for intestinal surgery and subsequent risk of diversion colitis are often-mentioned concerns. The outcomes of vaginal reconstructive surgery need to be appraised in order to improve understanding of pros and cons. To review literature on surgical techniques and clinical outcomes of intestinal vaginoplasty. Electronic databases and reference lists of published articles were searched for primary studies on intestinal vaginoplasty. Studies were included if these included at least five patients and had a minimal follow-up period of 1 year. No constraints were imposed with regard to patient age, indication for vaginoplasty, or applied surgical technique. Outcome measures were extracted and analyzed. Main outcome measures were surgical procedure, clinical outcomes, and outcomes concerning sexual health and quality of life. Twenty-one studies on intestinal vaginoplasty were included (including 894 patients in total). All studies had a retrospective design and were of low quality. Prevalence and severity of procedure-related complications were low. The main postoperative complication was introital stenosis, necessitating surgical correction in 4.1% of sigmoid-derived and 1.2% of ileum-derived vaginoplasties. Neither diversion colitis nor cancer was reported. Sexual satisfaction rate was high, but standardized questionnaires were rarely used. Quality of life was not reported. Based on evidence presently available, it seems that intestinal vaginoplasty is associated with low complication rates. To substantiate these findings and to obtain information about functional outcomes and quality of life, prospective studies

  7. Brachial plexus surgery: the role of the surgical technique for improvement of the functional outcome

    Directory of Open Access Journals (Sweden)

    Leandro Pretto Flores

    2011-08-01

    Full Text Available OBJECTIVE: The study aims to demonstrate the techniques employed in surgery of the brachial plexus that are associated to evidence-based improvement of the functional outcome of these patients. METHOD: A retrospective study of one hundred cases of traumatic brachial plexus injuries. Comparison between the postoperative outcomes associated to some different surgical techniques was demonstrated. RESULTS: The technique of proximal nerve roots grafting was associated to good results in about 70% of the cases. Significantly better outcomes were associated to the Oberlin's procedure and the Sansak's procedure, while the improvement of outcomes associated to phrenic to musculocutaneous nerve and the accessory to suprascapular nerve transfer did not reach statistical significance. Reinnervation of the hand was observed in less than 30% of the cases. CONCLUSION: Brachial plexus surgery renders satisfactory results for reinnervation of the proximal musculature of the upper limb, however the same good outcomes are not usually associated to the reinnervation of the hand.

  8. Phalloplasty with an Innervated Island Pedicled Anterolateral Thigh Flap in a Female-to-Male Transsexual

    OpenAIRE

    Hasegawa, Kenjiro; Namba, Yuzaburo; Kimata, Yoshihiro

    2013-01-01

    Since 2001, we have been performing phalloplasty with a radial forearm free flap as the flap of first choice in female-to-male transsexuals (FTMTS). In the present case, a 22-year-old FTMTS with a negative Allen test, we achieved good results by performing phalloplasty with an innervated island pedicled anterolateral thigh flap using the "tube within a tube" technique, in which the penis and urethra are constructed with a single flap. While phalloplasty with an island-pedicled or free anterol...

  9. [Pedicled versus free TRAM flap for breast reconstruction].

    Science.gov (United States)

    Galla, T J; Lukas, B; Feller, A M

    1999-03-01

    In breast reconstruction, the free TRAM-flap offers many advantages over the pedicled TRAM-flap. Due to its superior perfusion, the free flap rarely develops necrosis. Shaping of the flap is easier due to the lack of the thick muscle pedicle. Because the rectus muscle is spared, there is minimal donor site morbidity. However, the necessary microvascular anastomoses reduced the acceptance of the free TRAM-flap. During a 13-months period, 51 breast reconstructions were performed in 41 patients, 31 unilateral and ten bilateral. 45 flaps served for delayed reconstruction and six flaps for immediate reconstruction. The operations were performed by two teams working simultaneously. The average operating time was 3.9 hours for unilateral and 6.9 hours for bilateral delayed reconstruction. For immediate reconstruction, 6.2 and 6.3 hours were required for uni- and bilateral procedures, respectively. In 38 flaps, the thoracodorsal vessels served as recipient vessels; 13 flaps were anastomosed to the internal mammary artery and vein. Postoperative complications were observed in 13 patients. Three vessel anastomoses had to be revised. In one flap, a partial necrosis occurred; in two flaps hematoma evacuation was necessary. Two patients suffered from fat necroses at the abdomen and one umbilicus was lost. Skin irritations and seromas at the abdomen occurred in five patients. Pulmonary embolism was diagnosed in one patient three weeks postoperatively. Abdominal hernias or bulging in the epigastric area were not observed up to 15 months after reconstruction. These results reveal a low complication rate for breast reconstruction with the free TRAM-flap. The advantages of this technique as compared to the pedicled technique are discussed.

  10. Testing of a new prototype surgical stapler that automates the rollover sleeve technique for venous anastomoses

    Directory of Open Access Journals (Sweden)

    PATRICIA B CARROLL

    2006-01-01

    Full Text Available The creation of successful vascular anastomoses is of primary importance in many surgical fields. Numerous attempts to automate this process have been made. These techniques have slowly gained acceptance, but their use is still limited. This report details feasibility testing of a new prototype stapler that automates the rollover sleeve technique for venous vascular anastomoses. Male and female mongrel dogs (n=7 (25-32 kg were used. A segment of the right (n=5 or left (n=2 iliac vein was harvested for interposition grafts after the contra lateral side was transected. In each dog, two end-to-end venous anastomoses at the interposition grafts were performed. The standard anastomosis employed continuous mattress sutures. The experimental anastomosis was performed with a new prototype surgical stapler. The stapled anastomosis was proximal and the sutured was distal. In all experiments, it was possible to perform the experimental anastomosis with the stapler. Complications included two small leaks, one due to misfiring of a single pin in one experimental site. These leaks required suture reinforcement. One dog died of hemorrhage due to a slipped suture at the vein harvest site. One vein had thrombus seen at the sutured site although no technical abnormalities at either of the anastomoses could be found. After two weeks, grafts were inspected grossly and histologically. Healing appeared normal. There was a trend for less inflammatory cells infiltrating stapled sites; however, this was not statistically significant. The experiments demonstrate that this device can automate the rollover sleeve technique for venous anastomoses.

  11. Testing of a new prototype surgical stapler that automates the rollover sleeve technique for venous anastomoses.

    Science.gov (United States)

    Carroll, Patricia B; Defaria, Werviston; Gandia, Carlos; Berho, Mariana; Misiakos, Evangelos; Tzakis, Andreas G

    2006-01-01

    The creation of successful vascular anastomoses is of primary importance in many surgical fields. Numerous attempts to automate this process have been made. These techniques have slowly gained acceptance, but their use is still limited. This report details feasibility testing of a new prototype stapler that automates the rollover sleeve technique for venous vascular anastomoses. Male and female mongrel dogs (n=7) (25-32 kg) were used. A segment of the right (n=5) or left (n=2) iliac vein was harvested for interposition grafts after the contra lateral side was transected. In each dog, two end-to-end venous anastomoses at the interposition grafts were performed. The standard anastomosis employed continuous mattress sutures. The experimental anastomosis was performed with a new prototype surgical stapler. The stapled anastomosis was proximal and the sutured was distal. In all experiments, it was possible to perform the experimental anastomosis with the stapler. Complications included two small leaks, one due to misfiring of a single pin in one experimental site. These leaks required suture reinforcement. One dog died of hemorrhage due to a slipped suture at the vein harvest site. One vein had thrombus seen at the sutured site although no technical abnormalities at either of the anastomoses could be found. After two weeks, grafts were inspected grossly and histologically. Healing appeared normal. There was a trend for less inflammatory cells infiltrating stapled sites; however, this was not statistically significant. The experiments demonstrate that this device can automate the rollover sleeve technique for venous anastomoses.

  12. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  13. Evaluation of different surgical techniques in the management of subluxated cataractous lens.

    Science.gov (United States)

    Aldakaf, A; Bakir, H; Almogahed, A; Carstocea, Benone

    2007-01-01

    To compare and evaluate the outcome of different surgical techniques in the management of subluxated cataractous lens. This retrospective study included 18 eyes of 18 patients with subluxated cataracts of varying etiology. Their preoperative examination maintain included: best corrected visual acuity (BCVA), thorough anterior segment examination, by slit -lamp especially for the degree and extent of subluxation and cataract, cornea, iris and the pupil for other abnormalities or other traumatic signs, presence or absence of vitreous in the anterior chamber, IOP and finally fundus examination. The patients were then divided into 3 groups each comprising 6 patients. The first group underwent ECCE with sulcus implantation PMMA IOL , the second and third groups underwent phacoemulsification with bag implanted Acrylic IOL but the third group underwent special techniques and precautions during surgery. Postoperatively, all patients were examined for BCVA, IOP, IOL positioning, pupil, fundus examination. Thirteen patients were males and five were females. The etiology of subluxation was traumatic in ten males and two female. The ages of the patients were between 11 and 62 years old the post operative follow up period ranged between 7 and 16 months. No major intraoperative complications were noted. In the 1st group 2 patients underwent AC automated vitrectomy, 3 in the 2nd group, 1 in the 3rd group. Three patients needed scleral fixation suture . Thirteen patients had well centered IOL and 4 had slight decentration not necessitating further intervention and one in the 2nd group had clinically significant decentration where IOL explanation, widening of the wound and re implantation of a wide 6.5mm optic PMMA IOL was done in the second post operative daily. Subluxated cataracts need special precautions in the chosen surgical technique to maintain a reasonable safety level intraoperatively and an acceptable surgical.

  14. Pylorus-preserving Whipple pancreaticoduodenectomy: Postoperative evaluation of a new surgical technique

    International Nuclear Information System (INIS)

    Trerotola, S.O.; Jones, B.; Crist, D.J.; Cameron, J.L.

    1988-01-01

    The pylorus-preserving Whipple pancreaticoduodenectomy is becoming an increasingly popular alternative to the standard Whipple operation in the surgical treatment of diseases of the periampullary region. Contrast radiography plays an important role in the postoperative evaluation of patients undergoing this operation. Although most radiologists are familiar with the postoperative anatomy and complications associated with the standard Whipple operation, the newer technique involves different postoperative anatomy and different complications and requires a different approach to examination. The procedure presents several new diagnostic pitfalls. These variables are presented from a described series of 50 patients undergoing this procedure for periampullary neoplasm or chronic pancreatitis

  15. Anomalous Systemic Artery to the Left Lower Lobe: Literature Review and a New Surgical Technique.

    Science.gov (United States)

    Miller, Jacob R; Lancaster, Timothy S; Abarbanell, Aaron M; Manning, Peter B; Eghtesady, Pirooz

    2018-05-01

    Anomalous systemic arterial supply to the basal segments of the left lower lobe without coexisting pulmonary artery connection is a rare anomaly. Most feel treatment is necessary; however, the ideal strategy is unclear. Treatments described include embolization, pulmonary resection, or anastomosis to the native pulmonary artery. We recently encountered an infant with this anomaly and present a literature review summarizing all recent reports. Additionally, we describe a novel surgical technique to create a tension-free anastomosis utilizing segmental aortic translocation that we employed in our patient due to a large distance between the anomalous vessel and native left pulmonary artery.

  16. Suture fixation of migrated septal occluder device to prevent further migration: a simple surgical technique

    Directory of Open Access Journals (Sweden)

    Mohite Prashant N

    2013-01-01

    Full Text Available Abstract As the use of percutaneous intervention is increasing for the closure of the atrial septal defect, the procedure related complications are also on rise, migration of the device being most common. The migrated devices with failed percutaneous retrieval must be removed surgically under cardiopulmonary bypass. During establishment of cardiopulmonary bypass, the handling of heart may cause further migration of the device into other chambers of heart which leads to difficulty in finding and retrieval of the device. The authors propose a simple and unique technique to prevent further migration of the septal occluder device.

  17. A Case of Microstomia Subsequent to Toxic Epidermal Necrolysis Surgically Treated by Simple Technique

    Directory of Open Access Journals (Sweden)

    Takanobu Mashiko, MD

    2013-06-01

    Full Text Available Summary: Toxic epidermal necrolysis (TEN is a rare but severe adverse dermatitis that is an autoimmune reaction to drugs such as nonsteroidal anti-inflammatory drugs. TEN most severely affects the mucous membranes including the mouth and could develop into microstomia; however, microstomia in relation to TEN has rarely been reported in the literature. We describe an adult female patient who developed microstomia due to scar contracture of the bilateral oral commissures subsequent to TEN and was successfully treated by a simple surgical technique consisting solely of transverse incision of the commissure and longitudinal closure.

  18. Skull reconstruction after resection of bone tumors in a single surgical time by the association of the techniques of rapid prototyping and surgical navigation.

    Science.gov (United States)

    Anchieta, M V M; Salles, F A; Cassaro, B D; Quaresma, M M; Santos, B F O

    2016-10-01

    Presentation of a new cranioplasty technique employing a combination of two technologies: rapid prototyping and surgical navigation. This technique allows the reconstruction of the skull cap after the resection of a bone tumor in a single surgical time. The neurosurgeon plans the craniotomy previously on the EximiusMed software, compatible with the Eximius Surgical Navigator, both from the company Artis Tecnologia (Brazil). The navigator imports the planning and guides the surgeon during the craniotomy. The simulation of the bone fault allows the virtual reconstruction of the skull cap and the production of a personalized modelling mold using the Magics-Materialise (Belgium)-software. The mold and a replica of the bone fault are made by rapid prototyping by the company Artis Tecnologia (Brazil) and shipped under sterile conditions to the surgical center. The PMMA prosthesis is produced during the surgical act with the help of a hand press. The total time necessary for the planning and production of the modelling mold is four days. The precision of the mold is submillimetric and accurately reproduces the virtual reconstruction of the prosthesis. The production of the prosthesis during surgery takes until twenty minutes depending on the type of PMMA used. The modelling mold avoids contraction and dissipates the heat generated by the material's exothermic reaction in the polymerization phase. The craniectomy is performed with precision over the drawing made with the help of the Eximius Surgical Navigator, according to the planned measurements. The replica of the bone fault serves to evaluate the adaptation of the prosthesis as a support for the perforations and the placement of screws and fixation plates, as per the surgeon's discretion. This technique allows the adequate oncologic treatment associated with a satisfactory aesthetic result, with precision, in a single surgical time, reducing time and costs.

  19. Minimally Invasive Transforaminal Lumbar Interbody Fusion with Percutaneous Bilateral Pedicle Screw Fixation for Lumbosacral Spine Degenerative Diseases. A retrospective database of 40 consecutive treated cases and literature review.

    Science.gov (United States)

    Millimaggi, Daniele Francesco; DI Norcia, Valerio; Luzzi, Sabino; Alfiero, Tommaso; Galzio, Renato Juan; Ricci, Alessandro

    2017-04-12

    To report our results about minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) with bilateral pedicle screw fixation, in patients with degenerative lumbosacral spine disease. To describe the indications, surgical technique and results of a consecutive series of 40 patients undergone MI-TLIF. Despite the limited number of clinical studies, published data suggest tremendous potential advantages of this technique. Forty patients with radiological findings of degenerative lumbosacral spine disease were undergone MI-TLIF between July 2012 and January 2015. Clinical outcomes were assessed by means of Oswestry Disability Index (ODI) and Health Survey Scoring (SF36) before surgery and at first year follow-up. Furthermore, the following parameters were retrospectively reviewed: age, sex, working activity, body mass index (BMI), type of degenerative disease, number of levels of fusion, operative time, blood loss, length of hospital stay. Average operative time was of 230 minutes, mean estimated blood loss 170 mL, average length of hospital stay 5 days. The ODI improved from a score of 59, preoperatively, to post-operative score of 20 at first year follow-up. Average SF36 score increased from 36 to 54 (Physical Health) and from 29 to 50 (Mental Health) at first year outcome evaluation. MI-TLIF with bilateral pedicle screw fixation is an excellent choice for selected patients suffering from symptomatic degenerative lumbosacral spine disease, especially secondary to recurrent disk herniations.

  20. Study of the standard direct costs of various techniques of advanced endoscopy. Comparison with surgical alternatives.

    Science.gov (United States)

    Loras, Carme; Mayor, Vicenç; Fernández-Bañares, Fernando; Esteve, Maria

    2018-03-12

    The complexity of endoscopy has carried out an increase in cost that has a direct effect on the healthcare systems. However, few studies have analyzed the cost of advanced endoscopic procedures (AEP). To carry out a calculation of the standard direct costs of AEP, and to make a financial comparison with their surgical alternatives. Calculation of the standard direct cost in carrying out each procedure. An endoscopist detailed the time, personnel, materials, consumables, recovery room time, stents, pathology and medication used. The cost of surgical procedures was the average cost recorded in the hospital. Thirty-eight AEP were analyzed. The technique showing lowest cost was gastroscopy + APC (€116.57), while that with greatest cost was ERCP with cholangioscopy + stent placement (€5083.65). Some 34.2% of the procedures registered average costs of €1000-2000. In 57% of cases, the endoscopic alternative was 2-5 times more cost-efficient than surgery, in 31% of cases indistinguishable or up to 1.4 times more costly. Standard direct cost of the majority of AEP is reported using a methodology that enables easy application in other centers. For the most part, endoscopic procedures are more cost-efficient than the corresponding surgical procedure. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  1. "A tree must be bent while it is young": teaching urological surgical techniques to schoolchildren.

    Science.gov (United States)

    Buntrock, Stefan

    2012-01-01

    Playing video games in childhood may help achieve advanced laparoscopic skills later in life. The virtual operating room will soon become a reality, as "doctor games 2.0" will doubtlessly begin to incorporate virtual laparoscopic techniques. To teach surgical skills to schoolchildren in order to attract them to urology as a professional choice later in life. As part of EAU Urology Week 2010, 108 school children aged 15-19 attended a seminar with lectures and simulators (laparoscopy, TUR, cystoscopy, and suture sets) at the 62nd Congress of the German Society of Urology in Düsseldorf. A Pub-Med and Google Scholar search was also performed in order to review the beneficial effects of early virtual surgical training. MeSh terms used were "video games," "children," and "surgical skills." Searches were performed without restriction for a certain period of time. In terms of publicity for urology, EAU Urology Week, and the German Society of Urology, the event was immensely successful. Regarding the literature search, four relevant publications were found involving children. An additional three articles evaluated the usefulness of video gaming in medical students and residents. Making use of virtual reality to attract and educate a new generation of urologists is an important step in designing the future of urology.

  2. Clinical evaluation of patients undergoing dynamic pedicle fixation in lumbar spine

    Directory of Open Access Journals (Sweden)

    Felipe José Vieira Figueiredo

    2015-06-01

    Full Text Available OBJECTIVE: To evaluate the preliminary clinical results and complications in patients undergoing dynamic pedicle fixation of the spine in the treatment of a specific group of degenerative lumbar disease.METHODS: In this preliminary retrospective study, we selected 14 patients who underwent surgery from January 2006 to July 2010. We selected only patients with spondylolisthesis without spondylolysis (Grade 1 Meyerding. All patients underwent surgery at one level and the levels mostly addressed were: L3-L4, L4-L5 or L5-S1. The approach was the same in all patients (posterior median approach with preservation of the posterior elements. All patients underwent intense conservative treatment without clinical response and the same research algorithm preoperatively.RESULTS: Retrospective analysis of Oswestry questionnaire after selection and publication of results of 14 patients with Grade 1 spondylolisthesis who underwent dynamic pedicle stabilization in a total of 56 pedicle screws, being all in one level. There was no fracture of any screws, the mean hospital stay was a day and a half, no patient required blood transfusion and there were no cases of infection, with significant improvement in the Oswestry questionnaire.CONCLUSION: In this study, the dynamic pedicle stabilization method proved to be an excellent treatment option when surgical criteria are strictly adhered to. There was an improvement in Oswestry values, lower hospital stay and low rate of complications, consisting of an alternative in motion preservation surgery.

  3. Reducing surgical levels by paraspinal mapping and diffusion tensor imaging techniques in lumbar spinal stenosis.

    Science.gov (United States)

    Chen, Hua-Biao; Wan, Qi; Xu, Qi-Feng; Chen, Yi; Bai, Bo

    2016-04-25

    Correlating symptoms and physical examination findings with surgical levels based on common imaging results is not reliable. In patients who have no concordance between radiological and clinical symptoms, the surgical levels determined by conventional magnetic resonance imaging (MRI) and neurogenic examination (NE) may lead to a more extensive surgery and significant complications. We aimed to confirm that whether the use of diffusion tensor imaging (DTI) and paraspinal mapping (PM) techniques can further prevent the occurrence of false positives with conventional MRI, distinguish which are clinically relevant from levels of cauda equina and/or nerve root lesions based on MRI, and determine and reduce the decompression levels of lumbar spinal stenosis than MRI + NE, while ensuring or improving surgical outcomes. We compared the data between patients who underwent MRI + (PM or DTI) and patients who underwent conventional MRI + NE to determine levels of decompression for the treatment of lumbar spinal stenosis. Outcome measures were assessed at 2 weeks, 3 months, 6 months, and 12 months postoperatively. One hundred fourteen patients (59 in the control group, 54 in the experimental group) underwent decompression. The levels of decompression determined by MRI + (PM or DTI) in the experimental group were significantly less than that determined by MRI + NE in the control group (p = 0.000). The surgical time, blood loss, and surgical transfusion were significantly less in the experimental group (p = 0.001, p = 0.011, p = 0.001, respectively). There were no differences in improvement of the visual analog scale back and leg pain (VAS-BP, VAS-LP) scores and Oswestry Disability Index (ODI) scores at 2 weeks, 3 months, 6 months, and 12 months after operation between the experimental and control groups. MRI + (PM or DTI) showed clear benefits in determining decompression levels of lumbar spinal stenosis than MRI + NE. In patients with lumbar spinal

  4. Detour technique, Dipping technique, or IIeal bladder flap technique for surgical correction of uretero-ileal anastomotic stricture in orthotopic ileal neobladder

    Directory of Open Access Journals (Sweden)

    Mohamed Wishahi

    2015-08-01

    Full Text Available ABSTRACTBackground:Uretero-ileal anastomotic stricture (UIAS is a urological complication after ileal neobladder, the initial management being endourological intervention. If this fails or stricture recurs, surgical intervention will be indicated.Design and Participants:From 1994 to 2013, 129 patients were treated for UIAS after unsuccessful endourological intervention. Unilateral UIAS was present in 101 patients, and bilateral in 28 patients; total procedures were 157. The previous ileal neobladder techniques were Hautmann neobladder, detubularized U shape, or spherical shape neobladder.Surgical procedures:Dipping technique was performed in 74 UIAS. Detour technique was done in 60 renal units. Ileal Bladder flap was indicated in 23 renal units. Each procedure ended with insertion of double J, abdominal drain, and indwelling catheter.Results:Follow-up was done for 12 to 36 months. Patency of the anastomosis was found in 91.7 % of cases. Thirteen patients (8.3% underwent antegrade dilatation and insertion of double J.Conclusion:After endourological treatment for uretero-ileal anastomotic failure, basically three techniques may be indicated: dipping technique, detour technique, and ileal bladder flap. The indications are dependent on the length of the stenotic/dilated ureteral segment. Better results for long length of stenotic ureter are obtained with detour technique; for short length stenotic ureter dipping technique; when the stenotic segment is 5 cm or more with a short ureter, the ileal tube flap is indicated. The use of double J stent is mandatory in the majority of cases. Early intervention is the rule for protecting renal units from progressive loss of function.

  5. Virtual Surgical Planning for Correction of Delayed Presentation Scaphocephaly Using a Modified Melbourne Technique.

    Science.gov (United States)

    Macmillan, Alexandra; Lopez, Joseph; Mundinger, Gerhard S; Major, Melanie; Medina, Miguel A; Dorafshar, Amir H

    2018-02-23

    Late treatment of scaphocephaly presents challenges including need for more complex surgery to achieve desired head shape. Virtual surgical planning for total vault reconstruction may mitigate some of these challenges, but has not been studied in this unique and complex clinical setting. A retrospective chart review was conducted for patients with scaphocephaly who presented to our institution between 2000 and 2014. Patients presenting aged 12 months or older who underwent virtual surgical planning-assisted cranial vault reconstruction were included. Patient demographic, intraoperative data, and postoperative outcomes were recorded. Pre- and postoperative anthropometric measurements were obtained to document the fronto-occipital (FO) and biparietal (BP) distance and calculate cephalic index (CI). Virtual surgical planning predicted, and actual postoperative anthropometric measurements were compared. Five patients were identified who fulfilled inclusion criteria. The mean age was 50.6 months. One patient demonstrated signs of elevated intracranial pressure preoperatively. Postoperatively, all but one needed no revisional surgery (Whitaker score of 1). No patient demonstrated postoperative evidence of bony defects, bossing, or suture restenosis. The mean preoperative, simulated, and actual postoperative FO length was 190.3, 182, and 184.3 mm, respectively. The mean preoperative, simulated, and actual postoperative BP length was 129, 130.7, and 131 mm, respectively. The mean preoperative, simulated, and actual postoperative CI was 66, 72, and 71.3, respectively. Based on our early experience, virtual surgical planning using a modified Melbourne technique for total vault remodeling achieves good results in the management of late presenting scaphocephaly.

  6. Satisfactory patient-based outcomes after surgical treatment for idiopathic clubfoot: includes surgeon's individualized technique.

    Science.gov (United States)

    Mahan, Susan T; Spencer, Samantha A; Kasser, James R

    2014-09-01

    Treatment of idiopathic clubfoot has shifted towards Ponseti technique, but previously surgical management was standard. Outcomes of surgery have varied, with many authors reporting discouraging results. Our purpose was to evaluate a single surgeon's series of children with idiopathic clubfoot treated with a la carte posteromedial and lateral releases using the Pediatric Outcomes Data Collection Instrument (PODCI) with a minimum of 2-year follow-up. A total of 148 patients with idiopathic clubfoot treated surgically by a single surgeon over 15 years were identified, and mailed PODCI questionnaires. Fifty percent of the patients were located and responded, resulting in 74 complete questionnaires. Median age at surgery was 10 months (range, 5.3 to 84.7 mo), male sex 53/74 (71.6%), bilateral surgery 31/74 (41.9%), and average follow-up of 9.7 years. PODCI responses were compared with previously published normal healthy controls using t test for each separate category. Included in the methods is the individual surgeon's operative technique. In PODCIs where a parent reports for their child or adolescent, there was no difference between our data and the healthy controls in any of the 5 categories. In PODCI where an adolescent self-reports, there was no difference in 4 of 5 categories; significant difference was only found between our data (mean = 95.2; SD = 7.427) and normal controls (mean = 86.3; SD = 12.5) in Happiness Scale (P = 0.0031). In this group of idiopathic clubfoot patients, treated with judicious posteromedial release by a single surgeon, primarily when surgery was treatment of choice for clubfoot, patient-based outcomes are not different from their normal healthy peers through childhood and adolescence. While Ponseti treatment has since become the treatment of choice for clubfoot, surgical treatment, in some hands, has led to satisfactory results. Level III.

  7. Planned posterior assisted levitation in severe subluxated cataract: Surgical technique and clinical results

    Directory of Open Access Journals (Sweden)

    Tova Lifshitz

    2012-01-01

    Full Text Available We report the surgical technique and outcome of planned posterior assisted levitation (P-PAL in four cases of subluxated cataract. P-PAL was planned as the preferred approach in all cases. A spatula was inserted via the pars plana, the whole lens was lifted to the anterior chamber and then removed through a scleral tunnel incision. Anterior chamber intraocular lenses were implanted in all cases. All four eyes had severe subluxation of the crystalline lenses with marked phacodonesis. Two eyes had history of blunt trauma, and the other two eyes had severe pseudoexfoliation with spontaneous lens subluxation. Follow-up ranged from 1 to 2 years in three cases. The postoperative visual acuity was 20/80 or better. No intraoperative complications were observed. In conclusion, the P-PAL technique was successfully performed during cataract surgery in four eyes with severe subluxated cataracts. There were no complications over the long-term follow-up.

  8. [Endonasal versus trans-canalicular endoscopic dacriocystorhinostomy using diode laser. Surgical techniques and outcomes].

    Science.gov (United States)

    Piédrola Maroto, David; Franco Sánchez, Javier; Reyes Eldblom, Robin; Monje Vega, Elena; Conde Jiménez, Manuel; Ortiz Rueda, Manuel

    2008-01-01

    To evaluate the benefits and disadvantages of the endoscopic endonasal versus transcanalicular approaches using diode laser, and to compare their clinical outcomes. A total of 127 patients were operated on, 80 of them with the endonasal approach (Group I) and 47 with the transcanalicular technique (Group II). Epiphora improved completely in 67 patients in Group I (83.7 %) while the other 13 (16.2 %) continued to present the same symptoms. In Group II, a successful result was achieved in 39 patients (82.9 %) and 8 (17 %) of them had to be re-operated because of the persistence of epiphora. The surgical outcomes are similar with both laser techniques. The main advantages of using diode laser are that it does not require general anaesthesia, the lower intra- and peri-operative morbidity, the lack of nasal packing and the greater ease of performing additional interventions if it fails. The only real disadvantage of laser procedures is the high cost.

  9. Utilization of two different surgical techniques in gingival recession treatment: A comparative study

    Directory of Open Access Journals (Sweden)

    Bajić Miljan

    2014-01-01

    Full Text Available Introduction. Gingival recession is a displacement of gingival margin apically to cementenamel junction. Objective. The aim of this study was to compare the results achieved with two different surgical procedures used in gingival recession treatment. Methods. Ten patients with bilateral buccal recession on maxillary canines or premolars were included in the study. Professional teeth cleaning was performed before surgery. Recession on the experimental side was treated with connective tissue graft in combination with coronally advanced, split thickness flap (tunnel technique. Control side recession was treated with connective tissue graft in combination with trapezoidal coronally advanced, full thickness flap. Coin toss was used for side decision. The following parameters were evaluated before surgery and 6 months post-op: Vertical Recession Dimension, Clinical Attachment Level, Apico-coronal width of the keratinized tissue, Healing index (Laundry, RES index, and Patient evaluation of esthetic results. Student’s t-test was used for statistical analysis. Results. Six months after surgery, mean root coverage was 91.5±14.1% and 90.1±14.6% on the experimental and on the control side, respectively. RES index, Healing index (Laundry and Patient Subjective evaluation of esthetic results showed significantly better results (p≤0.05. Conclusion. Both surgical procedures produce highly successful clinical results based on evaluated parameters, but this tunnel technique provides significantly better esthetic results. [Projekat Ministarstva nauke Republike Srbije, br. III 41008: Interakcija etiopatogenetskih mehanizama parodontopatije i periimplantitisa sa sistemskim bolestima današnjice

  10. Anatomical study of lumbar vertebral pedicle and adjacent neural structures

    Directory of Open Access Journals (Sweden)

    Matuoka Cláudia Maria

    2002-01-01

    Full Text Available For the evaluation of the Lumbar pedicle morphometry and its relation to the neural structures, 14 male adult cadavers were dissected, and the size of the lumbar pedicle was assessed by measuring its sagittal and transversal diameter. It was found that the size of the pedicle increases from L2 to L5, both in the sagittal and transversal diameter, the first bigger. The relation of the lumbar pedicle to the neural structures was evaluated by measuring the distance between dura-mater and the pedicle medial area, the distance between the most distal area of the pedicle and the nerve root that appears under it, and , to obtain in an indirect way, the distance between the pedicle apex and the nerve root that appears over it. The acquired results showed that the distance between the most distal area of the pedicle and the nerve root that appears under it, and the distance between the pedicle medial area and dura-mater, do not increase from L2 to L5, and they are in average 1,98 and 3,02 respectively. The distance between the pedicle apex and the nerve root that appears over it, increases from L2 to L5, varying from 13,64 in L2 to 21,62 in L5. The location of the spinal ganglion in relation to the pedicle has also been found, and 87% of the spinal ganglions are located in the foraminal zone.

  11. Undertapping of Lumbar Pedicle Screws Can Result in Tapping With a Pitch That Differs From That of the Screw, Which Decreases Screw Pullout Force.

    Science.gov (United States)

    Bohl, Daniel D; Basques, Bryce A; Golinvaux, Nicholas S; Toy, Jason O; Matheis, Erika A; Bucklen, Brandon S; Grauer, Jonathan N

    2015-06-15

    Survey of spine surgeons and biomechanical comparison of screw pullout forces. To investigate what may be a suboptimal practice regularly occurring in spine surgery. In order for a tap to function in its intended manner, the pitch of the tap should be the same as the pitch of the screw. Undertapping has been shown to increase the pullout force of pedicle screws compared with line-to-line tapping. However, given the way current commercial lumbar pedicle screw systems are designed, undertapping may result in a tap being used that has a different pitch from that of the screw (incongruent pitch). A survey asked participants questions to estimate the proportion of cases each participant performed in the prior year using various hole preparation techniques. Participant responses were interpreted in the context of manufacturing specifications of specific instrumentation systems. Screw pullout forces were compared between undertapping with incongruent pitch and undertapping with congruent pitch using 0.16 g/cm polyurethane foam block and 6.5-mm screws. Of the 3679 cases in which participants reported tapping, participants reported line-to-line tapping in 209 cases (5%), undertapping with incongruent pitch in 1156 cases (32%), and undertapping with congruent pitch in 2314 cases (63%). The mean pullout force for undertapping with incongruent pitch was 56 N (8%) less than the mean pullout force for undertapping with congruent pitch. This is equivalent to 13 lb. This study estimates that for about 1 out of every 3 surgical cases with tapping of lumbar pedicle screws in the United States, hole preparation is being performed by undertapping with incongruent pitch. This study also shows that undertapping with incongruent pitch results in a decrease in pullout force by 8% compared with undertapping with congruent pitch. Steps should be taken to correct this suboptimal practice. 3.

  12. [A case of transverse colon cancer with multiple liver metastases and hepatic pedicle lymph node involvement showing pathological complete response by XELOX plus bevacizumab].

    Science.gov (United States)

    Mukai, Toshiki; Akiyoshi, Takashi; Koga, Rintaro; Arita, Junichi; Saiura, Akio; Ikeda, Atsushi; Nagasue, Yasutomo; Oikawa, Yoshinori; Yamakawa, Keiko; Konishi, Tsuyoshi; Fujimoto, Yoshiya; Nagayama, Satoshi; Fukunaga, Yosuke; Ueno, Masashi; Suenaga, Mitsukuni; Mizunuma, Nobuyuki; Shinozaki, Eiji; Yamamoto, Chiriko; Yamaguchi, Toshiharu

    2012-12-01

    A 70-year-old woman was referred to our hospital because of abdominal pain. Abdominal computed tomography(CT)and colonoscopy revealed transverse colon cancer with multiple liver metastases, with involvement of the hepatic pedicle and superior mesenteric artery lymph nodes. The patient received eight courses of XELOX plus bevacizumab, and CT showed a decrease in the size of the liver metastases and hepatic pedicle lymphadenopathy. Right hemicolectomy, partial hepatectomy, and hepatic pedicle lymph node resection were performed. Histopathological examination of the resected tissue revealed no residual cancer cells, suggesting a pathological complete response. The patient remains well 7 months after operation, without any signs of recurrence. Surgical resection should be considered for patients with initially unresectable colon cancer with liver metastases and hepatic pedicle lymph nodes involvement if systemic chemotherapy is effective.

  13. Direct surgical repair of spondylolysis in athletes: indications, techniques, and outcomes.

    Science.gov (United States)

    Drazin, Doniel; Shirzadi, Ali; Jeswani, Sunil; Ching, Harry; Rosner, Jack; Rasouli, Alexandre; Kim, Terrence; Pashman, Robert; Johnson, J Patrick

    2011-11-01

    Athletes present with back pain as a common symptom. Various sports involve repetitive hyperextension of the spine along with axial loading and appear to predispose athletes to the spinal pathology spondylolysis. Many athletes with acute back pain require nonsurgical treatment methods; however, persistent recurrent back pain may indicate degenerative disc disease or spondylolysis. Young athletes have a greater incidence of spondylolysis. Surgical solutions are many, and yet there are relatively few data in the literature on both the techniques and outcomes of spondylolytic repair in athletes. In this study, the authors undertook a review of the surgical techniques and outcomes in the treatment of symptomatic spondylolysis in athletes. A systematic review of the MEDLINE and PubMed databases was performed using the following key words to identify articles published between 1950 and 2011: "spondylolysis," "pars fracture," "repair," "athlete," and/or "sport." Papers on both athletes and nonathletes were included in the review. Articles were read for data on methodology (retrospective vs prospective), type of treatment, number of patients, mean patient age, and mean follow-up. Eighteen articles were included in the review. Eighty-four athletes and 279 nonathletes with a mean age of 20 and 21 years, respectively, composed the population under review. Most of the fractures occurred at L-5 in both patient groups, specifically 96% and 92%, respectively. The average follow-up period was 26 months for athletes and 86 months for nonathletes. According to the modified Henderson criteria, 84% (71 of 84) of the athletes returned to their sports activities. The time intervals until their return ranged from 5 to 12 months. For a young athlete with a symptomatic pars defect, any of the described techniques of repair would probably produce acceptable results. An appropriate preoperative workup is important. The ideal candidate is younger than 20 years with minimal or no listhesis and

  14. Repair-oriented classification of aortic insufficiency: impact on surgical techniques and clinical outcomes.

    Science.gov (United States)

    Boodhwani, Munir; de Kerchove, Laurent; Glineur, David; Poncelet, Alain; Rubay, Jean; Astarci, Parla; Verhelst, Robert; Noirhomme, Philippe; El Khoury, Gébrine

    2009-02-01

    Valve repair for aortic insufficiency requires a tailored surgical approach determined by the leaflet and aortic disease. Over the past decade, we have developed a functional classification of AI, which guides repair strategy and can predict outcome. In this study, we analyze our experience with a systematic approach to aortic valve repair. From 1996 to 2007, 264 patients underwent elective aortic valve repair for aortic insufficiency (mean age - 54 +/- 16 years; 79% male). AV was tricuspid in 171 patients bicuspid in 90 and quadricuspid in 3. One hundred fifty three patients had type I dysfunction (aortic dilatation), 134 had type II (cusp prolapse), and 40 had type III (restrictive). Thirty six percent (96/264) of the patients had more than one identified mechanism. In-hospital mortality was 1.1% (3/264). Six patients experienced early repair failure; 3 underwent re-repair. Functional classification predicted the necessary repair techniques in 82-100% of patients, with adjunctive techniques being employed in up to 35% of patients. Mid-term follow up (median [interquartile range]: 47 [29-73] months) revealed a late mortality rate of 4.2% (11/261, 10 cardiac). Five year overall survival was 95 +/- 3%. Ten patients underwent aortic valve reoperation (1 re-repair). Freedoms from recurrent Al (>2+) and from AV reoperation at 5 years was 88 +/- 3% and 92 +/- 4% respectively and patients with type I (82 +/- 9%; 93 +/- 5%) or II (95 +/- 5%; 94 +/- 6%) had better outcomes compared to type III (76 +/- 17%; 84 +/- 13%). Aortic valve repair is an acceptable therapeutic option for patients with aortic insufficiency. This functional classification allows a systematic approach to the repair of Al and can help to predict the surgical techniques required as well as the durability of repair. Restrictive cusp motion (type III), due to fibrosis or calcification, is an important predictor for recurrent Al following AV repair.

  15. A Unique Surgical Technique for Tracheostomy in Heterotopic Ossification: A Case Report.

    Science.gov (United States)

    Cheng, Esther; Thorpe, Eric

    2016-11-01

    To describe a technique for tracheostomy in heterotopic ossification that has not yet been described in the literature. We report a case of difficult tracheostomy while using conventional techniques in a 68-year-old patient who underwent mitral valve replacement requiring warfarin therapy three months prior. Imaging revealed heterotopic ossification overlying the trachea. A literature review was performed to identify similar cases or techniques. Extensive surgical planning was pursued after the initial attempted tracheostomy failed, and the airway was eventually accessed using a lighted intubation stylet for guidance and a drill. Heterotopic ossification has been described after orthopedic and abdominal surgeries. We identified one case report in the literature of tracheostomy performed in the setting of heterotopic ossification by an unspecified mechanism. There are few reported cases of tracheobronchial calcification in cardiac patients receiving warfarin therapy; however, these patients had characteristic imaging findings that were not consistent with those of our patient. We illustrate a safe and effective technique for tracheostomy in heterotopic ossification that has not been reported. Coordination with the anesthesia service was paramount for a successful operation. © The Author(s) 2016.

  16. Design of three-dimensional visualization based on the posterior lumbar pedicle screw fixation

    Directory of Open Access Journals (Sweden)

    Kai XU

    2011-09-01

    Full Text Available Objective To establish a three-dimensional visualization model of posterior lumbar pedicle screw fixation.Methods A patient with lumbar intervertebral disc hernia and another patient with compression fracture of lumbar vertebra were involved in the present study.Both patients underwent multi-slice spiral CT scan before and after lumbar pedicle screw fixation.The degree of preoperative vertebral compression,vertebral morphology before and after surgery,postoperative pedicle screw position,and decompression effects were observed.The original data of the multi-slice spiral CT were inputted into the computer.The three-dimensional reconstructed images of the lumbar and implanted screws were obtained using the software Amira 4.1 to show the three-dimensional shape of the lumbar vertebrae before and after surgery and the location of the implanted screws.Results The morphology and structure of the lumbar vertebrae before and after surgery and of the implanted screws were reconstructed using the digital navigation platform.The reconstructed 3D images could be displayed in multicolor,transparent,or arbitrary combinations.In the 3D surface reconstruction images,the location and structure of the implanted screws could be clearly observed,and the decompression of the spinal cord or nerve roots and the severity of the fracture and the compression of lumbar vertebrae could be fully evaluated.The reconstructed images before operation revealed the position of the vertebral pedicles and provided reference for intraoperative localization.Conclusions The three-dimensional computerized reconstructions of lumbar pedicle screw fixation may be valuable in basic research,clinical experiment,and surgical planning.The software Amira is one of the bases of three-dimensional reconstruction.

  17. Current Techniques of Teaching and Learning in Bariatric Surgical Procedures: A Systematic Review.

    Science.gov (United States)

    Kaijser, Mirjam; van Ramshorst, Gabrielle; van Wagensveld, Bart; Pierie, Jean-Pierre

    The gastric sleeve resection and gastric bypass are the 2 most commonly performed bariatric procedures. This article provides an overview of current teaching and learning methods of those techniques in resident and fellow training. A database search was performed on Pubmed, Embase, and the Education Resources Information Center (ERIC) to identify the methods used to provide training in bariatric surgery worldwide. After exclusion based on titles and abstracts, full texts of the selected articles were assessed. Included articles were reviewed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. In total, 2442 titles were identified and 14 full text articles met inclusion criteria. Four publications described an ex vivo training course, and 6 focused on at least 1 step of the gastric bypass procedure. Two randomized controlled trials (RCT) provided high-quality evidence on training aspects. Surgical coaching caused significant improvement of Bariatric Objective Structured Assessment of Technical Skills (BOSATS) scores (3.60 vs. 3.90, p = 0.017) and reduction of technical errors (18 vs. 10, p = 0.003). A preoperative warm-up increased global rating scales (GRS) scores on depth perception (p = 0.02), bimanual dexterity (p = 0.01), and efficiency of movements (p = 0.03). Stepwise education, surgical coaching, warming up, Internet-based knowledge modules, and ex vivo training courses are effective in relation to bariatric surgical training of residents and fellows, possibly shortening their learning curves. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  18. Application of virtual reality techniques in preoperative surgical planning for intracranial anterior circulation aneurysms

    Directory of Open Access Journals (Sweden)

    Shou-sen WANG

    2012-05-01

    Full Text Available Objective  To investigate the value of virtual reality (VR technique in the surgical planning for anterior circulation aneurysms of Willis circle. Methods  A total of 50 patients with 57 aneurysms confirmed by CT angiography in the anterior circle of Willis were enrolled in this study. In preoperative Hunt-Hess scale, grade Ⅰ was designated in 7 patients, grade Ⅱ in 22, grade Ⅲ in 17, grade Ⅳ in 3, grade Ⅴ in 1 patient. Among the aneurysms, 16 were small (≤5mm in diameter, 28 medium (5-15mm, 10 large (15-25mm and 3 giant (≥25mm in size. The thin-slice head scanning data were achieved by 64-slice spiral CT machine. These data was then transferred into Dextroscope image workstation. The virtual imaging system generated clear and vivid virtual images. We compared the findings between simulation surgical operation and actual operation. Results  VR system make the operator felt "personally on the scene" and was able to communicate with the imaging. It could not only visually display the anatomical structures in three dimensions, but also could simulate some surgical procedures, which basically simulated the same outcome of actual operation. All the 50 patients were successfully treated by microsurgical clipping of main aneurysmal or contributory aneurysmal necks. Conclusions  The surgeons is able to be more confident, and the identification for the complex vascular abnormality is improved by planning operative procedure in virtual-reality environment. The virtual-reality system makes the actual operative procedure more concise, thus it is of positive value in surgery for intracranial aneurysm.

  19. Esophagogastric pathology in morbid obese patient: preoperative diagnosis and influence in the selection of surgical technique

    Directory of Open Access Journals (Sweden)

    Sergio Estévez-Fernández

    2015-07-01

    Full Text Available Introduction: Given the difficulty in accessing to the excluded stomach after gastric bypass and the increase in gastroesophageal reflux after sleeve gastrectomy, it is justified to perform a preoperative fibrogastroscopy. The influence of the fibrogastroscopy (FGS findings in the therapeutic approach is analyzed. Patients and methods: A retrospective study of preoperative FGS findings is performed, from 04/06 to 12/12. The influence of the FGS results on the surgical technique selection, in the endoscopic or medical treatment and its relation to gastric fistula is analyzed by means of multivariate regression (confounding factors: Age, body mass index, arterial hypertension, diabetes mellitus, antiplatelet therapy, surgical technique (bariatric surgery, sleeve gastrectomy. Results: Three hundred thirty one patients are included: 32.6% biopsy of gastric lesion; 27% gastritis; 18.1% hiatal hernia; 3% metaplasia; 0.6% Barrett esophagus; 2.1% esophagitis; 0.3% dysplasia; 0.3 Schatzky's ring; 1.5% incompetent cardia; 2.4% duodenitis; 0.3% gastric erosions; 0.6% gastric xanthoma; 1.8%, gastric polyp; 1.6% duodenal ulcer; 0.6% papulo-erosive gastritis; 0.6% esophageal papilloma; 0.3% submucosal tumor. Helicobacter pylori+ 30.2% (triple therapy eradication in all patients. The FGS findings led to a variation in the surgical technique or to the completion of endoscopic treatment in 22.2% of cases. The gastric lesions did not influence the development of gastric fistula. Independent prognostic factors of fistula: Sleeve gastrectomy (7.9% vs. 2.7%; p = 0.02; OR: 1.38 IC95: 1.01-1.87 and the body mass index > 50 kg/m² (6.7% vs. 2.2%; p = 0.04; OR: 3.7 IC95: 1.12-12.4. Conclusions: The diagnosis of gastroesophageal disease through preoperative FGS motivated variations in the therapeutic approach in 52% of patients, so we consider essential to include the preoperative FGS in bariatric surgery.

  20. The Comparison Between the Complications after Two Surgical Techniques of Esophageal Cancer

    Directory of Open Access Journals (Sweden)

    Mohamad Taghi Rajabi Mashhadi

    2014-08-01

    Full Text Available Introduction: Esophageal cancer is a common gastro intestinal malignancy. One of the most common techniques of surgery in esophageal cancer is transhiatal esophagectomy with esophagogastric anastomosis in the neck. This technique is accompanied by complications like chronic gastero-esophegeal reflux and late stenosis. This study was designed to compare the risk of complications after two surgical techniques for esophageal cancer: esophagogastric anastomosis with partial fundoplication and esophagogastric anastomosis without it. Materials and Methods: In this retrospective cohort study, 100 patients with distal two thirds of esophageal cancer who underwent transhiatal esophagectomy in Ghaem and Omid hospitals Mashhad University of Medical Sciences from 2005 to 2010 were included. Esophagogastric anastomosis to the posterior gastric wall was performed with a partial gastric fundoplication in the first group but simple routine anastomosis was done to the posterior gastric wall in the second group. Results: In a retrospective cohort study 100 patients entered the study with 59 male & 41 female and with a mean age 54.6±6.4 years. Squamous cell carcinoma was observed in 77% of the patients and adenocarcinoma was reported in 23% of them. Seventy-two percent of tumours were located in distal third and 28% were in middle third of esophagus. Esophagogastric anastomotic leakage was observed in 3 cases of fundoplication group and 7 cases of simple anastomosis technique (P=0.182 so there was no significant difference between the two groups. Benign anastomosis stricture was reported in one of the patients who underwent esophagogastric anastomosis with fundoplication, but it was observed in 8 cases with simple anastomosis technique (P=0.03 so there was a significant difference between the two groups. Conclusion: Esophagogastric anastomosis with partial fundal fundoplication is a safe technique with low incidence of anatomic leakage and late stenosis.

  1. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model.

    Science.gov (United States)

    Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason

    2018-01-01

    Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Increasing distraction led to greater Spinal canal area. From 4.27 cm 2 to 5.72 cm 2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm 2 to 3.22 cm 2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. © The Authors, published by EDP Sciences, 2018.

  2. Surgical technique for ambulatory management of airsacculitis in a chimpanzee (Pan troglodytes).

    Science.gov (United States)

    Hill, L R; Lee, D R; Keeling, M E

    2001-02-01

    Bacterial infections of the air sac have been reported in many nonhuman primates. Approaches to the management of airsacculitis have included combinations of medical and surgical therapies. These strategies have often required repeated attempts to drain exudate from the affected air sac, as well as necessitating that the animal endure isolation or undergo intensive postoperative care before returning to its social group. A stoma was created via deliberate apposition of the air sac lining and skin to allow continuous drainage. Antibiotic therapy based on culture and antimicrobial susceptibility of the air sac contents was administered while the chimpanzee remained in its social group. We were able to attain complete resolution of the infection after a course of oral antibiotic therapy. The stoma closed gradually over a three-week period, and the chimpanzee has remained free of infection since that time. Despite the severity of the air sac infection in this chimpanzee, we were able to resolve the infection easily, using a simple surgical technique. This method allowed treatment without interfering with social standing or subjection to repeated anesthetic and treatment episodes. This method could be a simple, useful alternative for managing airsacculitis in nonhuman primates.

  3. [Cardiac myxoma -- the influence of preoperative clinical presentation and surgical technique on late outcome].

    Science.gov (United States)

    Mikić, Aleksandar; Obrenović-Krcanski, Bilijana; Kocica, Mladen; Vranes, Mile; Lacković, Vesna; Velinović, Milos; Miarković, Miroslav; Kovacević, Natasa; Djukić, Petar

    2007-01-01

    Cardiac myxomas are the most frequent primary tumours of the heart in adults, and they can be found in each of four cardiac chambers. Although biologically benign, due to their unfavourable localization, myxomas are considered "functionally malignant" tumours. Diagnosis of cardiac myxoma necessitates surgical treatment. To analyse: 1) the influence of localization, size and consistency of cardiac myxomas on preoperative symptomatology; 2) the influence of different surgical techniques (left, right, biatrial approach, tumour basis solving) on early, and late outcomes. From 1982 to 2000, at the Institute for Cardiovascular Diseases, Clinical Centre of Serbia, there were 46 patients with cardiac myxomas operated on, 67.4% of them women, mean age 47.1 +/- 16.3 years. The diagnosis was made according to clinical presentation, electrocardiographic and echocardiographic examinations and cardiac catheterization. Follow-up period was 4-18 (mean 7.8) years. In 41 (89.1%) patients, myxoma was localized in the left, while in 5 (10.9%), it was found in the right atrium. Average size was 5.8 x 3.8 cm (range: 1 x l cm to 9 x 8 cm) and 6 x 4 cm (range: 3 x 2 cm to 9 x 5 cm) for the left and right atrial myxomas, respectively. A racemous form predominated in the left (82.6%) and globous in the right (80%) atrium. Fatigue was the most common general (84.8%) and dyspnoea the most common cardiologic symptom (73.9%). Preoperative embolic events were present in 8 patients (4 pulmonary, 4 systemic). In our series: 1) different localization, size and consistency had no influence on the preoperative symptomatology; 2) surgical treatment applied, regardless of different approaches and basis solving, resulted in excellent functional improvements (63.1% patients in NYHA III and IV class preoperatively vs. 6.7% patients postoperatively) and had no influence on new postoperative rhythm disturbances (8.7% patients preoperatively vs. 24.4% patients postoperatively); 3) early (97.8%), and late

  4. A review of the surgical management of breast cancer: plastic reconstructive techniques and timing implications.

    Science.gov (United States)

    Rosson, Gedge D; Magarakis, Michael; Shridharani, Sachin M; Stapleton, Sahael M; Jacobs, Lisa K; Manahan, Michele A; Flores, Jaime I

    2010-07-01

    The oncologic management of breast cancer has evolved over the past several decades from radical mastectomy to modern-day preservation of chest and breast structures. The increased rate of mastectomies over recent years made breast reconstruction an integral part of the breast cancer management. Plastic surgery now offers patients a wide variety of reconstruction options from primary closure of the skin flaps to performance of microvascular and autologous tissue transplantation. Well-coordinated partnerships between surgical oncologists, plastic surgeons, and patients address concerns of tumor control, cosmesis, and patients' wishes. The gamut of breast reconstruction options is reviewed, particularly noting state-of-the-art techniques, as well as the advantages and disadvantages of various timing modalities.

  5. Traumatic intercostal arterial bleeding controlled with a novel surgical technique: a case report

    Directory of Open Access Journals (Sweden)

    Miettinen Simo

    2012-09-01

    Full Text Available Abstract Introduction A blunt thoracic trauma may cause arterial bleeding requiring operative treatment or endovascular embolization or endovascular aortic stenting. A novel damage control technique to stop such bleeding is presented. Case presentation We present the case of an 82-year-old Caucasian man who experienced rib fractures I-VII on the left side and bleeding from damaged intercostal arteries after a blunt thoracic trauma. Emergency thoracotomy was performed. Conclusions Effective hemostasis was achieved by using a rolled surgical swab and inserting it against the chest wall next to the aorta with sutures pulled through the intercostal muscles and then sutured to the back side of the patient. The patient died four days after the surgery due to a head injury sustained in the car crash.

  6. Ex-vivo partial nephrectomy after living donor nephrectomy: Surgical technique for expanding kidney donor pool

    Directory of Open Access Journals (Sweden)

    Yaw A Nyame

    2017-01-01

    Full Text Available Renal transplantation has profound improvements in mortality, morbidity, and overall quality of life compared to renal replacement therapy. This report aims to illustrate the use of ex-vivo partial nephrectomy in a patient with a renal angiomyolipoma prior to living donor transplantation. The surgical outcomes of the donor nephrectomy and recipient transplantation are reported with 2 years of follow-up. Both the donor and recipient are healthy and without any significant comorbidities. In conclusion, urologic techniques such as partial nephrectomy can be used to expand the living donor pool in carefully selected and well informed transplant recipients. Our experience demonstrated a safe and positive outcome for both the recipient and donor, and is consistent with other reported outcomes in the literature.

  7. Use of 3D Printed Bone Plate in Novel Technique to Surgically Correct Hallux Valgus Deformities

    Science.gov (United States)

    Smith, Kathryn E.; Dupont, Kenneth M.; Safranski, David L.; Blair, Jeremy; Buratti, Dawn; Zeetser, Vladimir; Callahan, Ryan; Lin, Jason; Gall, Ken

    2016-01-01

    Three-dimensional (3-D) printing offers many potential advantages in designing and manufacturing plating systems for foot and ankle procedures that involve small, geometrically complex bony anatomy. Here, we describe the design and clinical use of a Ti-6Al-4V ELI bone plate (FastForward™ Bone Tether Plate, MedShape, Inc., Atlanta, GA) manufactured through 3-D printing processes. The plate protects the second metatarsal when tethering suture tape between the first and second metatarsals and is a part of a new procedure that corrects hallux valgus (bunion) deformities without relying on doing an osteotomy or fusion procedure. The surgical technique and two clinical cases describing the use of this procedure with the 3-D printed bone plate are presented within. PMID:28337049

  8. Robotic transverse colectomy for mid-transverse colon cancer: surgical techniques and oncologic outcomes.

    Science.gov (United States)

    Jung, Kyung Uk; Park, Yoonah; Lee, Kang Young; Sohn, Seung-Kook

    2015-06-01

    Robot-assisted surgery for colon cancer has been reported in many studies, most of which worked on right and/or sigmoid colectomy. The aim of this study was to report our experience of robotic transverse colectomy with an intracorporeal anastomosis, provide details of the surgical technique, and present the theoretical benefits of the procedure. This is a retrospective review of prospectively collected data of robotic surgery for colorectal cancer performed by a single surgeon between May 2007 and February 2011. Out of 162 consecutive cases, we identified three robotic transverse colectomies, using a hand-sewn intracorporeal anastomosis. Two males and one female underwent transverse colectomies for malignant or premalignant disease. The mean docking time, time spent using the robot, and total operative time were 5, 268, and 307 min, respectively. There were no conversions to open or conventional laparoscopic technique. The mean length of specimen and number of lymph nodes retrieved were 14.1 cm and 6.7, respectively. One patient suffered from a wound seroma and recovered with conservative management. The mean hospital stay was 8.7 days. After a median follow-up of 72 months, there were no local or systemic recurrences. Robotic transverse colectomy seems to be a safe and feasible technique. It may minimize the necessity of mobilizing both colonic flexures, with facilitated intracorporeal hand-sewn anastomosis. However, further prospective studies with a larger number of patients are required to draw firm conclusions.

  9. Surgical treatment of an acquired posterior urethral diverticulum with cystoscopy assisted robotic technique.

    Science.gov (United States)

    Guneri, Cagri; Kirac, Mustafa; Biri, Hasan

    2017-03-01

    A 42-year-old man with a history of recurrent urethral stenosis, recurrent urinary tract infection and macroscopic hematuria has referred to our clinic. He underwent several internal urethrotomies and currently using clean intermittent self-catheterization. During the internal urethrotomy, we noted a large posterior urethral diverticulum (UD) between verumontanum and bladder neck. His obstructive symptoms were resolved after the catheter removal. But perineal discomfort, urgency and dysuria were prolonged about 3-4 weeks. Urinalysis and urine culture confirmed recurrent urinary tract infections. Due to this conditions and symptoms, we planned a surgical approach which was planned as transperitoneal robotic-assisted laparoscopic approach. This technique is still applied for the diverticulectomy of the bladder. In addition to this we utilized the cystoscopy equipments for assistance. During this process, cystoscope was placed in the UD to help the identification of UD from adjacent tissues like seminal vesicles by its movement and translumination. Operating time was 185 min. On the post-operative third day he was discharged. Foley catheter was removed after 2 weeks. Urination was quite satisfactory. His perineal discomfort was resolved. The pathology report confirmed epidermoid (tailgut) cyst of the prostate. Urethrogram showed no radiologic signs of UD after 4 weeks. Irritative and obstructive symptoms were completely resolved after 3 months. No urinary incontinence, erectile dysfunction or retrograde ejaculation was noted. While posterior UD is an extremely rare situation, surgical treatment of posterior UD remains uncertain. To our knowledge, no above-mentioned cystoscopy assisted robotic technique for the treatment was described in the literature.

  10. Surgical technique for en bloc transurethral resection of bladder tumour with a Hybrid Knife(®).

    Science.gov (United States)

    Islas-García, J J O; Campos-Salcedo, J G; López-Benjume, B I; Torres-Gómez, J J; Aguilar-Colmenero, J; Martínez-Alonso, I A; Gil-Villa, S A

    2016-05-01

    Bladder cancer is the second most common malignancy of the urinary tract and the 9th worldwide. Latin American has an incidence of 5.6 per 100,000 inhabitants per year. Seventy-five percent of newly diagnosed cases are nonmuscle invasive bladder cancer, and 25% of cases present as muscle invasive. The mainstay of treatment for nonmuscle invasive bladder cancer is loop transurethral resection. In 2013, the group led by Dr Mundhenk of the University Hospital of Tübingen, Germany, was the first to describe the Hybrid Knife(®) equipment for performing en bloc bladder tumour resection, with favourable functional and oncological results. To describe the surgical technique of en bloc bladder tumour resection with a Hybrid Knife(®) as an alternative treatment for nonmuscle invasive bladder tumours. A male patient was diagnosed by urotomography and urethrocystoscopy with a bladder tumour measuring 2×1cm on the floor. En bloc transurethral resection of the bladder tumour was performed with a Hybrid Knife(®). Surgery was performed for 35min, with 70 watts for cutting and 50 watts for coagulation, resecting and evacuating en bloc the bladder tumour, which macroscopically included the muscle layer of the bladder. There were no complications. The technique of en bloc bladder tumour resection with Hybrid Knife(®) is an effective alternative to bipolar loop transurethral resection. Resection with a Hybrid Knife(®) is a procedure with little bleeding and good surgical vision and minimises the risk of bladder perforation and tumour implants. The procedure facilitates determining the positivity of the neoplastic process, vascular infiltration and bladder muscle invasion in the histopathology study. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Outcome and safety analysis of 3D printed patient specific pedicle screw jigs for complex spinal deformities: A comparative study.

    Science.gov (United States)

    Garg, Bhavuk; Gupta, Manish; Singh, Menaka; Kalyanasundaram, Dinesh

    2018-05-03

    Spinal deformities are very challenging to treat and have a great risk of neurological complications due to hardware placement during corrective surgery. Various techniques have been introduced to ensure safe and accurate placement of pedicle screws. Patient-specific screw guides with pre-drawn and pre-validated trajectory seems to be an attractive option. We have focused on developing 3D printing technique for complex spinal deformities in India. This study also aimed to compare the placement of pedicle screw with 3D printing and free hand technique. This is a retrospective comparative clinical study at an academic institutional setting. A total of 20 patients were enrolled during the study, 10 were operated with the help of 3D printing (group 1) and 10 were operated with freehand technique (group 2). Group 1 included 6 congenital, 3 adolescent idiopathic scoliosis (AIS), one post tubercular kyphosis and Group 2 included 5 congenital, 4 AIS and one post tubercular kyphosis patient. Primary outcomes were measured in terms of screw violation and secondary outcome were measured in terms of Surgical time, Blood loss, Radiation exposure (no. of shoots required) and complications. MIMICS v18.0 Software was used for 3D reconstruction from CT scan images of all the patients. 3-Matic software was used to create drill guide. 3-D printer from Stratasys Mojo ABS P 430 model material cartilage (a thermoplastic material) was used for printing of vertebrae model and jigs. Two sample test of proportion was used to compare correctly and wrongly pedicle screw placement with 3D printing and freehand technique. T-test with equal variance was used for operating surgical time and blood loss. This work was carried out by collaboration of Orthopaedics Department, All India Institute of Medical Sciences (AIIMS), New Delhi and Biomedical Engineering Department, Indian Institute of Technology (IIT) Delhi. This project received the grant of USD 60000 from Department of Biotechnology (DBT

  12. Re-implant of the right coronary artery: a surgical technique for the treatment of ostial lesions

    Directory of Open Access Journals (Sweden)

    Bongiovani Hércules Lisboa

    2002-01-01

    Full Text Available Previously described surgical treatment for ostial coronary artery stenosis relied on either venous or arterial bypasses or ostial patch angioplasty. These surgical procedures are performed with bovine pericardium, saphenous vein or internal thoracic artery. We describe a technique of right coronary artery re-implantation into the aorta. The procedure was performed in four patients with right coronary artery ostial stenosis along with other left coronary artery lesions.

  13. Comparative evaluation of diode laser ablation and surgical stripping technique for gingival depigmentation: A clinical and immunohistochemical study.

    Science.gov (United States)

    Bakutra, Gaurav; Shankarapillai, Rajesh; Mathur, Lalit; Manohar, Balaji

    2017-01-01

    There are various treatment modalities to remove the black patches of melanin pigmentation. The aim of the study is to clinically compare the diode laser ablation and surgical stripping technique for gingival depigmentation and to evaluate their effect on the histological changes in melanocyte activity. A total of 40 sites of 20 patients with bilateral melanin hyperpigmentation were treated with the surgical stripping and diode laser ablation technique. Change in Hedin index score, change in area of pigmentation using image analyzing software, pain perception, patient preference of treatment were recorded. All 40 sites were selected for immunohistochemical analysis using HMB-45 immunohistochemical marker. At 12 months post-operative visit, in all sites, repigmentation was observed with different grades of Hedin index. Paired t -test, analysis of variance, and Chi-square tests were used for statistical analysis. Repigmentation in surgical stripping is significantly lesser compared to laser ablation. Lesser numbers of melanocytes were found on immunohistological examination at 12 months postoperatively. Comparison for patient preference and pain indices give statistically significant values for diode laser techniques. Gingival hyperpigmentation is effectively managed by diode laser ablation technique and surgical stripping method. In this study, surgical stripping technique found to be better compared to diode laser ablation.

  14. Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review

    Science.gov (United States)

    Shadid, Rola Muhammed; Sadaqah, Nasrin Rushdi; Othman, Sahar Abdo

    2014-01-01

    Background. A number of surgical techniques for implant site preparation have been advocated to enhance the implant of primary and secondary stability. However, there is insufficient scientific evidence to support the association between the surgical technique and implant stability. Purpose. This review aimed to investigate the influence of different surgical techniques including the undersized drilling, the osteotome, the piezosurgery, the flapless procedure, and the bone stimulation by low-level laser therapy on the primary and/or secondary stability of dental implants. Materials and methods. A search of PubMed, Cochrane Library, and grey literature was performed. The inclusion criteria comprised observational clinical studies and randomized controlled trials (RCTs) conducted in patients who received dental implants for rehabilitation, studies that evaluated the association between the surgical technique and the implant primary and/or secondary stability. The articles selected were carefully read and classified as low, moderate, and high methodological quality and data of interest were tabulated. Results. Eight clinical studies were included then they were classified as moderate or high methodological quality and control of bias. Conclusions. There is a weak evidence suggesting that any of previously mentioned surgical techniques could influence the primary and/or secondary implant stability. PMID:25126094

  15. Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review

    Directory of Open Access Journals (Sweden)

    Rola Muhammed Shadid

    2014-01-01

    Full Text Available Background. A number of surgical techniques for implant site preparation have been advocated to enhance the implant of primary and secondary stability. However, there is insufficient scientific evidence to support the association between the surgical technique and implant stability. Purpose. This review aimed to investigate the influence of different surgical techniques including the undersized drilling, the osteotome, the piezosurgery, the flapless procedure, and the bone stimulation by low-level laser therapy on the primary and/or secondary stability of dental implants. Materials and methods. A search of PubMed, Cochrane Library, and grey literature was performed. The inclusion criteria comprised observational clinical studies and randomized controlled trials (RCTs conducted in patients who received dental implants for rehabilitation, studies that evaluated the association between the surgical technique and the implant primary and/or secondary stability. The articles selected were carefully read and classified as low, moderate, and high methodological quality and data of interest were tabulated. Results. Eight clinical studies were included then they were classified as moderate or high methodological quality and control of bias. Conclusions. There is a weak evidence suggesting that any of previously mentioned surgical techniques could influence the primary and/or secondary implant stability.

  16. Pedicle frozen autograft for limb sparing surgery in a dog with femoral osteosarcoma

    Directory of Open Access Journals (Sweden)

    Aline Silva Gouvêa

    Full Text Available ABSTRACT: Osteosarcoma (OSA is the most common bone tumor diagnosed in dogs and represents approximately 85% of canine skeletal tumors. The most commonly employed therapy is amputation of the limb followed by chemotherapy. However, preservation of the afflicted limb has been successful for patients with concomitant neurological or orthopedic conditions, which are contraindications to the complete amputation, or with owners reluctant to the possibility of amputation. For these reasons, the purpose of this study was to describe the technical procedures that allowed limb salvage through the use of pedicle frozen grafts in a dog with femoral OSA. Surgical procedures consisted of a femoral diaphyseal osteotomy with tearing of the soft tissues; thus, creating a bone pedicle that was frozen in liquid nitrogen according to the protocol outlined by TSUCHIYA et al. (2005. Limb function remained satisfactory for six months.

  17. Use of Supplemental Short Pre-Contoured Accessory Rods and Cobalt Chrome Alloy Posterior Rods Reduces Primary Rod Strain and Range of Motion Across the Pedicle Subtraction Osteotomy Level

    DEFF Research Database (Denmark)

    Hallager, Dennis Winge; Gehrchen, Poul Martin; Dahl, Benny

    2016-01-01

    and rod strain is necessary to determine the biomechanical efficacy of these techniques. METHODS: Five specimens (T12-S1) underwent PSO at L3 with pedicle screw stabilization at L1-S1. Pedicle subtraction was adjusted to achieve a final lordosis of 70°. Flexion-extension (FE), lateral bending, and axial...

  18. A Novel Surgical Pre-suturing Technique for the Management of ...

    African Journals Online (AJOL)

    cannot be protruded beyond lower incisor teeth because of a short lingual ... suggests that surgical interventions are absolutely safe at any age including ... Surgical procedures indicated for ankyloglossia are highly predictable but shows poor ...

  19. Avaliação tomográfica dos pedículos vertebrais no tratamento cirúrgico dos pacientes com escoliose idiopática do adolescente Evaluación de tomografía computarizada de pedículos vertebrales nel tratamiento quirúrgico de escoliosis idiopática del adolescente Computed tomography scan evaluation of vertebral pedicles for surgical treatment of adolescent idiopathic scoliosis

    Directory of Open Access Journals (Sweden)

    Alceu Gomes Chueire

    2012-12-01

    curva cerca. CONCLUSIÓN: Los límites aceptables invasión no se determinaron también, y también los métodos de medición no están estandarizados. La técnica "free hand" resultó segura, además de violación pedículo. Pre-Op CT Scan mostró útil en la cirugía de la planificación y evitar complicaciones.OBJECTIVE: To Evaluate by CT scan tridimensional reconstruction, malpositioning of pedicle screws in adolescent idiopathic scoliosis patients. METHODS: It was analyzed CT scan cuts of 8 patients submitted to surgical treatment in Hospital de Base de São José do Rio Preto- SP, which were performed posterior spinal fusion from T2/T4 to L4/L5, 164 screws were inserted. RESULTS: 32,9% (n=54 were malpositioned offering potential risk, which was considered 2mm deviation, 20,1% (n=33 lateral invasion, 9,1% (n=15 medial invasion, 3,6% (n= 6 anterior invasion. From those malpositioned screws 46% (n=25 were in concavity, 35% (n=19 in convexity and 19% (n=10 were nearby curve. CONCLUSION: Acceptable invasion boundaries were not well determined, and also measurements methods are not standardized. The "free hand" technique proved safe, besides pedicle violation. Pre-Op CT Scan showed helpful in surgery planning and avoiding complications.

  20. [Free tissue transfers with lengthening of vascular pedicle using interpositional vein grafts. About 10 cases].

    Science.gov (United States)

    Yeo, S; Perrot, P; Duteille, F

    2010-04-01

    The realization of free flaps with lack of reliable vessels nearby the loss of substance is a difficult problem for plastic surgeons. We report 10 cases of free tissue transfers with a one-stage technique lengthening the vascular pedicle of the free flap with interpositional vein grafts. Taking into consideration the good results and the low rate of morbidity, the authors emphasize the use of this technique rather than a two-stage procedure. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  1. Laparoscopic radical prostatectomy by extraperitoneal access with duplication of the open technique

    Directory of Open Access Journals (Sweden)

    M. Tobias-Machado

    2004-06-01

    Full Text Available INTRODUCTION: The laparoscopic radical prostatectomy is a continually developing technique. Transperitoneal access has been preferred by the majority of centers that employ this technique. Endoscopic extraperitoneal access is used by a few groups, nevertheless it is currently receiving a higher acceptance. In general, the antegrade technique is used, with dissection from the bladder neck to the prostate apex. The objective of the present paper is to describe the extraperitoneal technique with reproduction of the open surgery's surgical steps. SURGICAL TECHNIQUE: With this technique, the dissection of the prostate apex is performed and, following the section of the urethra while preserving the sphincteric apparatus, the Foley catheter is externally tied and internally recovered, which allows cranial traction, similarly to the way it is performed in conventional surgery. The retroprostatic space is posteriorly dissected and the seminal vesicles are identified by anterior and posterior approach, obtaining with this method an optimal exposure of the posterolateral pedicles and the prostate contour. The initial impression is that this technique does not present higher bleeding rate or difficulty level when compared with antegrade surgery. Potential advantages of this technique would be the greater familiarity with surgical steps, isolated extraperitoneal drainage of urine and secretions and a good definition of prostate limits and lateral pedicles, which are critical factors for preserving the neurovascular bundles and avoiding positive surgical margins. A higher number of cases and a long-term follow-up will demonstrate its actual value as a technical option for endoscopic access to the prostate.

  2. Real-time surgical simulation for deformable soft-tissue objects with a tumour using Boundary Element techniques

    Science.gov (United States)

    Wang, P.; Becker, A. A.; Jones, I. A.; Glover, A. T.; Benford, S. D.; Vloeberghs, M.

    2009-08-01

    A virtual-reality real-time simulation of surgical operations that incorporates the inclusion of a hard tumour is presented. The software is based on Boundary Element (BE) technique. A review of the BE formulation for real-time analysis of two-domain deformable objects, using the pre-solution technique, is presented. The two-domain BE software is incorporated into a surgical simulation system called VIRS to simulate the initiation of a cut on the surface of the soft tissue and extending the cut deeper until the tumour is reached.

  3. Real-time surgical simulation for deformable soft-tissue objects with a tumour using Boundary Element techniques

    International Nuclear Information System (INIS)

    Wang, P; Becker, A A; Jones, I A; Glover, A T; Benford, S D; Vloeberghs, M

    2009-01-01

    A virtual-reality real-time simulation of surgical operations that incorporates the inclusion of a hard tumour is presented. The software is based on Boundary Element (BE) technique. A review of the BE formulation for real-time analysis of two-domain deformable objects, using the pre-solution technique, is presented. The two-domain BE software is incorporated into a surgical simulation system called VIRS to simulate the initiation of a cut on the surface of the soft tissue and extending the cut deeper until the tumour is reached.

  4. Comparison of two surgical techniques for creating an acute myocardial infarct in rats

    Directory of Open Access Journals (Sweden)

    Luiz Guilherme Achcar Capriglione

    2014-12-01

    Full Text Available Objective: To perform a comparative assessment of two surgical techniques that are used creating an acute myocardial infarc by occluding the left anterior descending coronary artery in order to generate rats with a left ventricular ejection fraction of less than 40%. Methods: The study was completely randomized and comprised 89 halothane-anaesthetised rats, which were divided into three groups. The control group (SHAM comprised fourteen rats, whose left anterior descending coronary artery was not occluded. Group 1 (G1: comprised by 35 endotracheally intubated and mechanically ventilated rats, whose left anterior descending coronary artery was occluded. Group 2 (G2: comprised 40 rats being manually ventilated using a nasal respirator whose left anterior descending coronary artery was occluded. Other differences between the two techniques include the method of performing the thoracotomy and removing the pericardium in order to expose the heart, and the use of different methods and suture types for closing the thorax. Seven days after surgery, the cardiac function of all surviving rats was determined by echocardiography. Results: No rats SHAM group had progressed to death or had left ventricular ejection fraction less than 40%. Nine of the 16 surviving G1 rats (56.3% and six of the 20 surviving G2 rats (30% had a left ventricular ejection fraction of less than 40%. Conclusion: The results indicate a tendency of the technique used in G1 to be better than in G2. This improvement is probably due to the greater duration of the open thorax, which reduces the pressure over time from the surgeon, allowing occlusion of left anterior descending coronary artery with higher accuracy.

  5. Current surgical practices in cleft care: cleft palate repair techniques and postoperative care.

    Science.gov (United States)

    Katzel, Evan B; Basile, Patrick; Koltz, Peter F; Marcus, Jeffrey R; Girotto, John A

    2009-09-01

    The purpose of this study was to objectively report practices commonly used in cleft palate repair in the United States. This study investigates current surgical techniques, postoperative care, and complication rates for cleft palate repair surgery. All 803 surgeon members of the American Cleft Palate-Craniofacial Association were sent online and/or paper surveys inquiring about their management of cleft palate patients. Three-hundred six surveys were received, a 38 percent response rate. This represented responses of surgeons from 100 percent of American Cleft Palate-Craniofacial Association registered cleft teams. Ninety-six percent of respondents perform a one-stage repair. Eighty-five percent of surgeons perform palate surgery when the patient is between 6 and 12 months of age. The most common one-stage repair techniques are the Bardach style (two flaps) with intravelar veloplasty and the Furlow palatoplasty. After surgery, 39 percent of surgeons discharge patients within 24 hours. Another 43 percent discharge patients within 48 hours. During postoperative management, 92 percent of respondents implement feeding restrictions. Eighty-five percent of physicians use arm restraints. Surgeons' self-reported complications rates are minimal: 54 percent report a fistula in less than 5 percent of cases. The reported need for secondary speech surgery varies widely. The majority of respondents repair clefts in one stage. The most frequently used repair techniques are the Furlow palatoplasty and the Bardach style with intravelar veloplasty. After surgery, the majority of surgeons discharge patients in 1 or 2 days, and nearly all surgeons implement feeding restrictions and the use of arm restraints. The varying feeding protocols are reviewed in this article.

  6. Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique.

    Science.gov (United States)

    Nevzati, Edin; Rey, Jeannine; Coluccia, Daniel; D'Alonzo, Donato; Grüter, Basil; Remonda, Luca; Fandino, Javier; Marbacher, Serge

    2017-10-01

    The steady progess in the armamentarium of techniques available for endovascular treatment of intracranial aneurysms requires affordable and reproducable experimental animal models to test novel embolization materials such as stents and flow diverters. The aim of the present project was to design a safe, fast, and standardized surgical technique for stent assisted embolization of saccular aneurysms in a rat animal model. Saccular aneurysms were created from an arterial graft from the descending aorta.The aneurysms were microsurgically transplanted through end-to-side anastomosis to the infrarenal abdominal aorta of a syngenic male Wistar rat weighing >500 g. Following aneurysm anastomosis, aneurysm embolization was performed using balloon expandable magnesium stents (2.5 mm x 6 mm). The stent system was retrograde introduced from the lower abdominal aorta using a modified Seldinger technique. Following a pilot series of 6 animals, a total of 67 rats were operated according to established standard operating procedures. Mean surgery time, mean anastomosis time, and mean suturing time of the artery puncture site were 167 ± 22 min, 26 ± 6 min and 11 ± 5 min, respectively. The mortality rate was 6% (n=4). The morbidity rate was 7.5% (n=5), and in-stent thrombosis was found in 4 cases (n=2 early, n=2 late in stent thrombosis). The results demonstrate the feasibility of standardized stent occlusion of saccular sidewall aneurysms in rats - with low rates of morbidity and mortality. This stent embolization procedure combines the opportunity to study novel concepts of stent or flow diverter based devices as well as the molecular aspects of healing.

  7. 3D printing-assisted preoperative plan of pedicle screw placement for middle-upper thoracic trauma: a cohort study.

    Science.gov (United States)

    Xu, Wei; Zhang, Xuming; Ke, Tie; Cai, Hongru; Gao, Xiang

    2017-08-11

    This study aimed to evaluate the application of 3D printing in assisting preoperative plan of pedicle screw placement for treating middle-upper thoracic trauma. A preoperative plan was implemented in seven patients suffering from middle-upper thoracic (T3-T7) trauma between March 2013 and February 2016. In the 3D printing models, entry points of 56 pedicle screws (Magerl method) and 4 important parameters of the pedicle screws were measured, including optimal diameter (ϕ, mm), length (L, mm), inclined angle (α), head-tilting angle (+β), and tail-tilting angle (-β). In the surgery, bare-hands fixation of pedicle screws was performed using 3D printing models and the measured parameters as guidance. A total of seven patients were enrolled, including five men and two women, with the age of 21-62 years (mean age of 37.7 years). The position of the pedicle screw was evaluated postoperatively using a computerized tomography scan. Totally, 56 pedicle screws were placed, including 33 pieces of level 0, 18 pieces of level 1, 4 pieces of level 2 (pierced lateral wall), and 1 piece of level 3 (pierced lateral wall, no adverse consequences), with a fine rate of 91.0%. 3D printing technique is an intuitive and effective assistive technology to pedicle screw fixation for treating middle-upper thoracic vertebrae, which improve the accuracy of bare-hands screw placement and reduce empirical errors. The trial was approved by the Ethics Committee of the Fujian Provincial Hospital. It was registered on March 1st, 2013, and the registration number was K2013-03-001.

  8. Use of the Toric Surgical Marker to Aid in Intraoperative Plaque Placement for the USC Eye Physics Plaques to Treat Uveal Melanoma: A New Surgical Technique.

    Science.gov (United States)

    Berry, Jesse L; Kim, Jonathan W; Jennelle, Richard; Astrahan, Melvin

    2015-09-01

    To describe a new surgical technique for intraoperative placement of Eye Physics (EP) plaques for uveal melanoma using a toric marker. A toric marker is designed for cataract surgery to align the axis of astigmatism; its use was modified in this protocol to mark the axis of suture coordinates as calculated by Plaque Simulator (PS) software. The toric marker can be used to localize suture coordinates, in degrees, during intraoperative plaque placement. Linear marking using the toric marker decreases potential inaccuracies associated with the surgeon estimating 'clock-hours' by dot placement. Use of the toric marker aided surgical placement of EP plaques. The EP planning protocol is now designed to display the suture coordinates either by clock-hours or degrees, per surgeon preference. Future research is necessary to determine whether routine use of the toric marker improves operative efficiency. [Ophthalmic Surg Lasers Imaging Retina. 2015;46:866-870.]. Copyright 2015, SLACK Incorporated.

  9. Localization techniques for guided surgical excision of non-palpable breast lesions.

    Science.gov (United States)

    Chan, Benjamin K Y; Wiseberg-Firtell, Jill A; Jois, Ramesh H S; Jensen, Katrin; Audisio, Riccardo A

    2015-12-31

    contrast, WGL had fewer postoperative complications to both ROLL (RR 1.18, 95% CI 0.71 to 1.98; 642 participants; four trials) and RSL (RR 1.51, 95% CI 0.75 to 3.03; 305 participants; one trial), although this was also not statistically significant.The overall quality of evidence was good. The main risk of bias amongst included studies consisted of incomplete data sets, selective reporting, and allocation concealment. Interpretation and applicability of this meta-analysis was hindered by the mixed indication of diagnostic versus therapeutic purposes when undertaking WGL, ROLL, or RSL, leading to a high level of mixed pathology in numerous trials. Other limitations include underpowered studies, lack of data in standardized format for meta-analysis, lack of complete data amongst the trials, and absence of long-term data. Owing to a lack of trials in certain localization techniques, we could only draw conclusions about ROLL and RSL versus WGL. There is no clear evidence to support one guided technique for surgically excising a non-palpable breast lesion over another. Results from this Cochrane review support the continued use of WGL as a safe and tested technique that allows for flexibility in selected cases when faced with extensive microcalcification. ROLL and RSL could be offered to patients as a comparable replacement for WGL as they are equally reliable. Other techniques such as IOUS, RCML, and CAL are of academic interest, but recommendation for routine use in the clinical environment and oncological outcomes require further validation. The results of this Cochrane review also stress the need for more fully powered RCTs to evaluate the best technique according to the comprehensive criteria described, with a more consistent and standardized approach in outcome reporting.

  10. Recurrent tricuspid insufficiency: is the surgical repair technique a risk factor?

    Science.gov (United States)

    Kara, Ibrahim; Koksal, Cengiz; Cakalagaoglu, Canturk; Sahin, Muslum; Yanartas, Mehmet; Ay, Yasin; Demir, Serdar

    2013-01-01

    This study compares the medium-term results of De Vega, modified De Vega, and ring annuloplasty techniques for the correction of tricuspid insufficiency and investigates the risk factors for recurrent grades 3 and 4 tricuspid insufficiency after repair. In our clinic, 93 patients with functional tricuspid insufficiency underwent surgical tricuspid repair from May 2007 through October 2010. The study was retrospective, and all the data pertaining to the patients were retrieved from hospital records. Functional capacity, recurrent tricuspid insufficiency, and risk factors aggravating the insufficiency were analyzed for each patient. In the medium term (25.4 ± 10.3 mo), the rates of grades 3 and 4 tricuspid insufficiency in the De Vega, modified De Vega, and ring annuloplasty groups were 31%, 23.1%, and 6.1%, respectively. Logistic regression analysis revealed that chronic obstructive pulmonary disease, left ventricular dysfunction (ejection fraction, tricuspid insufficiency. Medium-term survival was 90.6% for the De Vega group, 96.3% for the modified De Vega group, and 97.1% for the ring annuloplasty group. Ring annuloplasty provided the best relief from recurrent tricuspid insufficiency when compared with DeVega annuloplasty. Modified De Vega annuloplasty might be a suitable alternative to ring annuloplasty when rings are not available.

  11. Bilateral posterior tarsal tunnel syndrome caused by accessory flexor digitorum longus; case report and surgical technique.

    Science.gov (United States)

    Schmidt-Hebbel, A; Elgueta, J; Villa, A; Mery, P; Filippi, J

    To present a case report of bilateral posterior tarsal tunnel syndrome (PTTS) caused by an accessory flexor digitorum longus (AFDL), including the surgical technique and a review of the literature. Twenty-nine year old male diagnosed with bilateral PTTS, refractory to conservative management, with 53 points on the preoperative AOFAS score. MR of both ankles showed an AFDL within the tarsal tunnel, in close relationship to the posterior tibial nerve. Bilateral tarsal tunnel decompression and AFDL resection was performed. There were no post-operative complications. At 6 months after surgery, the patient had no pain and had 87 points on the AOFAS score. The PTTS is an entrapment neuropathy of the posterior tibial nerve or one of its terminal branches. A rare cause is the presence of an AFDL, and its resection is associated with good clinical results. Careful scar tissue resection and neurolysis is recommended. Knowing the normal pathway and anatomical variability of the posterior tibial nerve and its branches is essential to avoid iatrogenic injury. In our case report, MR and intraoperative findings identified a bilateral FDLA in close relationship to the common flexor digitorum, an unusual finding, with few reports in current literature. Careful tarsal tunnel decompression and AFDL resection in our patient with bilateral symptomatic PTTS has good clinical results and no complications, particularly when diagnosed and treated early. Copyright © 2015 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Two-Stage Tissue-Expander Breast Reconstruction: A Focus on the Surgical Technique

    Directory of Open Access Journals (Sweden)

    Elisa Bellini

    2017-01-01

    Full Text Available Objective. Breast cancer, the most common malignancy in women, comprises 18% of all female cancers. Mastectomy is an essential intervention to save lives, but it can destroy one’s body image, causing both physical and psychological trauma. Reconstruction is an important step in restoring patient quality of life after the mutilating treatment. Material and Methods. Tissue expanders and implants are now commonly used in breast reconstruction. Autologous reconstruction allows a better aesthetic result; however, many patients prefer implant reconstruction due to the shorter operation time and lack of donor site morbidity. Moreover, this reconstruction strategy is safe and can be performed in patients with multiple health problems. Tissue-expander reconstruction is conventionally performed as a two-stage procedure starting immediately after mammary gland removal. Results. Mastectomy is a destructive but essential intervention for women with breast cancer. Tissue expansion breast reconstruction is a safe, reliable, and efficacious procedure with considerable psychological benefits since it provides a healthy body image. Conclusion. This article focuses on this surgical technique and how to achieve the best reconstruction possible.

  13. Distal fascia lata lengthening: an alternative surgical technique for recalcitrant trochanteric bursitis

    Science.gov (United States)

    Ortega, Javier; García-Rayo, Ramón; Resines, Carlos

    2009-01-01

    This article presents a simple technique for fascia lata lengthening that is less aggressive, can be performed under local anaesthetic with little morbidity and disability, and has excellent results. Eleven patients (13 hips) were enrolled in this study. Mean age was 54.6 years, there was one man and ten women. Outcomes were assessed by using a visual analog pain scale, Harris hip score and Lickert scale (satisfaction). There was a mean follow-up time of 43 months (range 15–84). All patients were scored by the Harris hip scale with a mean improvement from 61 (range 48–77) to 91 (range 76–95) after surgery. The mean visual analogue scale (VAS) score improved from 83 (range 60–99) to 13 (range 0–70). We had 12 of 13 patients reporting a good result. Mean surgical time was 15 min, and only one seroma was reported as a complication. No inpatient management was needed. In conclusion, distal “Z” lengthening of the fascia lata appears to be a good alternative for treatment of this condition. PMID:19214507

  14. Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.

    Science.gov (United States)

    Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld

    2005-03-01

    Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.

  15. Arthroscopic Surgical Technique for an Acute Talar Dome Osteochondral Lesion in a Professional Rugby League Player.

    Science.gov (United States)

    Sullivan, Martin; Fraser, Ethan J; Linklater, James; Harris, Craig; Morgan, Kieran

    2017-06-01

    Talar osteochondral lesions represent challenging clinical entities, particularly in high-demand athletes. Surgical treatment of large lesions often requires a 2-step procedure, or the use of osteotomy in the case of autologous osteochondral transfer, which can delay return to sport. A professional rugby league player underwent surgery for a complex injury to the ankle. A talar osteochondral lesion with a maximal diameter of 15 mm was treated in an arthroscopic fashion using the cartilage taken from the completely displaced osteochondral fragment. Cartilage was cut into chips and combined with bone graft product containing platelet-derived growth factor and a porous collagen scaffold. Autologous cartilage was then reimplanted arthroscopically. The patient was allowed full ankle motion from 2 weeks postoperatively, and weightbearing was commenced at 6 weeks. Follow-up imaging and functional outcomes, including return to sport, were assessed at regular intervals. The patient was able to return to professional rugby league by 23 weeks postoperatively. Magnetic resonance imaging at 16 months postoperatively showed restoration of the subchondral plate and osseous infill. At final follow-up, the patient remained pain free and was playing at preinjury level. This report describes good outcomes using a novel, 1-step cartilage repair technique to treat a large talar osteochondral lesion in a professional athlete. Level V: Expert opinion.

  16. Laparoscopic cystostomy in pigs: Technique and comparison with traditional open cystostomy for surgical stress

    Directory of Open Access Journals (Sweden)

    Hua Zhang

    2014-01-01

    Full Text Available Cystostomy is a common procedure in veterinary surgery. We describe a technique for laparoscopic cystostomy (LC group; n = 7 in Bama miniature pigs and compare the surgical stress induced by this procedure to open cystostomy (OC group; n = 7. A three-portal approach was used for laparoscopic cystostomy. First, we placed 2 simple interrupted sutures between the ventral body wall and urinary bladder. Then, a purse-string suture was placed in the urinary bladder wall, approximately 1 cm cranially to the two sutures. A stab incision was made at the center of the purse-string suture and a 12-F Foley catheter advanced into the urinary bladder; the suture was then pulled tightly and tied. Again, two interrupted sutures were placed 1 cm cranially to the catheter, between the ventral body wall and the bladder, to establish cystopexy. The extracorporeal portion of the catheter was fixed to the skin by a finger-trap suture. Blood samples were collected to measure the white blood cell count and serum concentrations of cortisol, interleukin-6, and C-reactive protein; follow-up laparoscopy was performed 1 month after the surgery. Laparoscopic cystotomy was successfully performed in all the pigs; the mean operating time was 43 ± 5 min. The levels of the stress markers reflected a lower stress response for LC than OC. Thus, LC appears to be better than OC both in terms of technique and physiological responses elicited, and may be more suitable than OC in the creation of experimental animal models for investigations on urinary diseases and those requiring diversion of urine flow.

  17. Early harvesting of the vascularized pedicled nasoseptal flap during endoscopic skull base surgery.

    Science.gov (United States)

    Eloy, Jean Anderson; Patel, Amit A; Shukla, Pratik A; Choudhry, Osamah J; Liu, James K

    2013-01-01

    The vascularized pedicled nasoseptal flap (PNSF) represents a successful option for reconstruction of large skull base defects after expanded endoscopic endonasal approaches (EEA). This vascularized flap can be harvested early or late in the operation depending on the anticipation of high-flow CSF leaks. Each harvesting technique (early vs. late) is associated with different advantages and disadvantages. In this study, we evaluate our experience with early harvesting of the PNSF for repair of large skull base defects after EEA. A retrospective review was performed at a tertiary care medical center on patients who underwent early PNSF harvesting during reconstruction of intraoperative high-flow CSF leaks after EEA between December 2008 and March 2012. Demographic data, repair materials, surgical approach, and incidence of PNSF usage were collected. Eighty-seven patients meeting the inclusion criteria were identified. In 86 procedures (98.9%), the PNSF harvested at the beginning of the operation was used. In 1 case (1.1%), the PNSF was not used because a high-flow intraoperative CSF leak was not encountered. This patient had recurrence of intradural disease 8months later, and the previously elevated PNSF was subsequent used after tumor resection. Based on our data, a high-flow CSF leak and need for a PNSF can be accurately anticipated in patients undergoing EEA for skull base lesions. Because of the advantages of early harvesting of the PNSF and the high preoperative predictive value of CSF leak anticipations, this technique represents a feasible harvesting practice for EEA surgeries. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Pilot study: evaluation of the use of the convergent interview technique in understanding the perception of surgical design and simulation.

    Science.gov (United States)

    Logan, Heather; Wolfaardt, Johan; Boulanger, Pierre; Hodgetts, Bill; Seikaly, Hadi

    2013-06-19

    It is important to understand the perceived value of surgical design and simulation (SDS) amongst surgeons, as this will influence its implementation in clinical settings. The purpose of the present study was to examine the application of the convergent interview technique in the field of surgical design and simulation and evaluate whether the technique would uncover new perceptions of virtual surgical planning (VSP) and medical models not discovered by other qualitative case-based techniques. Five surgeons were asked to participate in the study. Each participant was interviewed following the convergent interview technique. After each interview, the interviewer interpreted the information by seeking agreements and disagreements among the interviewees in order to understand the key concepts in the field of SDS. Fifteen important issues were extracted from the convergent interviews. In general, the convergent interview was an effective technique in collecting information about the perception of clinicians. The study identified three areas where the technique could be improved upon for future studies in the SDS field.

  19. Masculinizing Top Surgery: A Systematic Review of Techniques and Outcomes.

    Science.gov (United States)

    Wilson, Stelios C; Morrison, Shane D; Anzai, Lavinia; Massie, Jonathan P; Poudrier, Grace; Motosko, Catherine C; Hazen, Alexes

    2018-02-02

    Chest wall masculinization by means of mastectomy is an important gender affirming surgery for transmasculine and non-binary patients. Limited data exist comparing commonly used techniques in masculinizing top surgery, and most are single institution studies. A systematic review was performed on primary literature dedicated specifically to the technical aspects and outcomes of mastectomy for masculinizing top surgery. For each study, patient demographics and surgical outcomes were compared. Eight studies met inclusion criteria. There were 2138 breasts with an average patient age of 28.6 years and the average breast weight was 353 g. The most commonly reported techniques are those without skin resection (8.0%), those with periareolar skin resection (34.1%), inferior pedicle mammoplasty (15.7%), and inframammary fold skin excision with free nipple grafting (FNG, 42.2%). In total, 6.0% of all breasts required acute reoperation for hematoma and 26.5% required secondary operations. Acute reoperation occurred significantly less often in the FNG cohort (4.8%) compared with both the inferior pedicle mammaplasty cohort (8.9%, P < 0.05) and techniques without skin resection cohort (10.3%, P < 0.05). Secondary operations occurred significantly more often in the periareolar skin resection cohort (37.5%) than techniques without skin resection cohort (19.0%, P < 0.01), inferior pedicle mammaplasty cohort (27.9%, P < 0.01), and FNG cohort (20.3%, P < 0.05). In addition, secondary operations occurred significantly more often in inferior pedicle mammaplasty cohort (27.9%) compared with FNG cohort (20.3%, P < 0.01). This analysis notes several significant differences with regard to percentage requiring acute reoperation and percentage requiring secondary revision based on technique. Candidates for masculinizing top surgery should be educated on these differences.

  20. An evaluation of surgical outcome of bilateral cleft lip surgery using a modified Millard′s (Fork Flap technique

    Directory of Open Access Journals (Sweden)

    W L Adeyemo

    2013-01-01

    Full Text Available Background: The central third of the face is distorted by the bilateral cleft of the lip and palate and restoring the normal facial form is one of the primary goals for the reconstructive surgeons. The history of bilateral cleft lip repair has evolved from discarding the premaxilla and prolabium and approximating the lateral lip elements to a definitive lip and primary cleft nasal repair utilising the underlying musculature. The aim of this study was to review surgical outcome of bilateral cleft lip surgery (BCLS done at the Lagos University Teaching Hospital. Materials and Methods: A review of all cases of BCLS done between January 2007 and December 2012 at the Lagos University Teaching Hospital was done. Data analysis included age and sex of patients, type of cleft deformity and type of surgery (primary or secondary and whether the cleft deformity was syndromic and non-syndromic. Techniques of repair, surgical outcome and complications were also recorded. Results: A total of 39 cases of BCLS involving 21 males and 18 females were done during the period. This constituted 10% (39/390 of all cases of cleft surgery done during the period. There were 5 syndromic and 34 non-syndromic cases. Age of patients at time of surgery ranged between 3 months and 32 years. There were 24 bilateral cleft lip and palate deformities and 15 bilateral cleft lip deformities. Thirty-one of the cases were primary surgery, while 8 were secondary (revision surgery. The most common surgical technique employed was modified Fork flap (Millard technique, which was employed in 37 (95% cases. Conclusion: Bilateral cleft lip deformity is a common cleft deformity seen in clinical practice, surgical repair of which can be a challenge to an experienced surgeon. A modified Fork flap technique for repair of bilateral cleft lip is a reliable and versatile technique associated with excellent surgical outcome.

  1. Accelerating orthodontic tooth movement: A new, minimally-invasive corticotomy technique using a 3D-printed surgical template

    Science.gov (United States)

    Giansanti, Matteo

    2016-01-01

    Background A reduction in orthodontic treatment time can be attained using corticotomies. The aggressive nature of corticotomy due to the elevation of muco-periosteal flaps and to the duration of the surgery raised reluctance for its employ among patients and dental community. This study aims to provide detailed information on the design and manufacture of a 3D-printed CAD-CAM (computer-aided design and computer-aided manufacturing) surgical guide which can aid the clinician in achieving a minimally-invasive, flapless corticotomy. Material and Methods An impression of dental arches was created; the models were digitally-acquired using a 3D scanner and saved as STereoLithography ( STL ) files. The patient underwent cone beam computed tomography (CBCT): images of jaws and teeth were transformed into 3D models and saved as an STL file. An acrylic template with the design of a surgical guide was manufactured and scanned. The STLs of jaws, scanned casts, and acrylic templates were matched. 3D modeling software allowed the view of the 3D models from different perspectives and planes with perfect rendering. The 3D model of the acrylic template was transformed into a surgical guide with slots designed to guide, at first, a scalpel blade and then a piezoelectric cutting insert. The 3D STL model of the surgical guide was printed. Results This procedure allowed the manufacturing of a 3D-printed CAD/CAM surgical guide, which overcomes the disadvantages of the corticotomy, removing the need for flap elevation. No discomfort, early surgical complications or unexpected events were observed. Conclusions The effectiveness of this minimally-invasive surgical technique can offer the clinician a valid alternative to other methods currently in use. Key words:Corticotomy, orthodontics, CAD/CAM, minimally invasive, surgical template, 3D printer. PMID:27031067

  2. WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

    International Nuclear Information System (INIS)

    Gorman, A; Seabrook, G; Brakken, A; Dubois, M; Marn, C; Wilson, C; Jacobson, D; Liu, Y

    2015-01-01

    Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6. They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles

  3. One-Step Cartilage Repair Technique as a Next Generation of Cell Therapy for Cartilage Defects: Biological Characteristics, Preclinical Application, Surgical Techniques, and Clinical Developments.

    Science.gov (United States)

    Zhang, Chi; Cai, You-Zhi; Lin, Xiang-Jin

    2016-07-01

    To provide a comprehensive overview of the basic science rationale, surgical technique, and clinical outcomes of 1-step cartilage repair technique used as a treatment strategy for cartilage defects. A systematic review was performed in the main medical databases to evaluate the several studies concerning 1-step procedures for cartilage repair. The characteristics of cell-seed scaffolds, behavior of cells seeded into scaffolds, and surgical techniques were also discussed. Clinical outcomes and quality of repaired tissue were assessed using several standardized outcome assessment tools, magnetic resonance imaging scans, and biopsy histology. One-step cartilage repair could be divided into 2 types: chondrocyte-matrix complex (CMC) and autologous matrix-induced chondrogenesis (AMIC), both of which allow a simplified surgical approach. Studies with Level IV evidence have shown that 1-step cartilage repair techniques could significantly relieve symptoms and improve functional assessment (P studies clearly showed hyaline-like cartilage tissue in biopsy tissues by second-look arthroscopy. The 1-step cartilage repair technique, with its potential for effective, homogeneous distribution of chondrocytes and multipotent stem cells on the surface of the cartilage defect, is able to regenerate hyaline-like cartilage tissue, and it could be applied to cartilage repair by arthroscopy. Level IV, systematic review of Level II and IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model

    OpenAIRE

    Hughes Matthew; Papadakos Nikolaos; Bishop Tim; Bernard Jason

    2018-01-01

    Introduction: Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Methods: Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar sp...

  5. Accuracy of computer-assisted cervicle pedicle screw installation

    International Nuclear Information System (INIS)

    Zhang Honglei; Zhou Dongsheng; Jang Zhensong

    2009-01-01

    Objective: To investigate the accuracy of computer-assisted cervical pedicle screw installation and the reason of screw malposition. Methods: A total of 172 cervical pedicle screws were installed by computer-assisted navigation for 30 patients with lower cervical spinal diseases. All the patients were examined by X-ray and CT after operation. Screw's position and direction were measured on the sagittal and transectional images of intraoperative navigation and post-operative CT. Then linear regression analysis was taken between navigational and post-operative CT's images. Results: Two screws perforated the upper pedicle wall, 3 perforated the lateral pedicle wall.There was a positive linear correlation between navigational and post-operative CT's images. Conclusion: Computer-assisted navigation can provide the high accuracy of cervical pedicle screw installation and excursion phenomenon is reason of screw malposition. (authors)

  6. Microscope-integrated intraoperative optical coherence tomography-guided small-incision lenticule extraction: New surgical technique.

    Science.gov (United States)

    Sharma, Namrata; Urkude, Jayanand; Chaniyara, Manthan; Titiyal, Jeewan S

    2017-10-01

    We describe the surgical technique of microscope-integrated intraoperative optical coherence tomography (OCT)-guided small-incision lenticule extraction. The technique enables manual tracking of surgical instruments and identification of the desired dissection plane. It also helps discern the relation between the dissector and the intrastromal lenticule. The dissection plane becomes hyperreflective on dissection, ensuring complete separation of the intrastromal lenticule from the overlying and underlying stroma. Inadvertent posterior plane entry, cap-lenticule adhesion, incomplete separation of the lenticule, creation of a false plane, and lenticule remnants may be recognized intraoperatively so corrective steps can be taken immediately. In cases with a hazy overlying cap, microscope-integrated intraoperative OCT enables localization and extraction of the lenticule. The technique is helpful for inexperienced surgeons, especially in cases with low amplitudes of refractive errors, ie, thin lenticules. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Surgical techniques in radiation induced temporal lobe necrosis in nasopharyngeal carcinoma patients.

    Science.gov (United States)

    Alfotih, Gobran Taha Ahmed; Zheng, Mei Guang; Cai, Wang Qing; Xu, Xin Ke; Hu, Zhen; Li, Fang Cheng

    2016-01-01

    Radiation induced brain injury ranges from acute reversible edema to late, irreversible radiation necrosis. Radiation induced temporal lobe necrosis is associated with permanent neurological deficits and occasionally progresses to death. We present our experience with surgery on radiation induced temporal lobe necrosis (RTLN) in nasopharyngeal carcinoma (NPC) patients with special consideration of clinical presentation, surgical technique, and outcomes. This retrospective study includes 12 patients with RTLN treated by the senior author between January 2010 and December 2014. Patients initially sought medical treatment due to headache; other symptoms were hearing loss, visual deterioration, seizure, hemiparesis, vertigo, memory loss and agnosia. A temporal approach through a linear incision was performed for all cases. RTLN was found in one side in 7 patients, and bilaterally in 5. 4 patients underwent resection of necrotic tissue bilaterally and 8 patients on one side. No death occurred in this series of cases. There were no post-operative complications, except 1 patient who developed aseptic meningitis. All 12 patients were free from headache. No seizure occurred in patients with preoperative epilepsy. Other symptoms such as hemiparesis and vertigo improved in all patients. Memory loss, agnosia and hearing loss did not change post-operatively in all cases. The follow-up MR images demonstrated no recurrence of necrotic lesions in all 12 patients. Neurosurgical intervention through a temporal approach with linear incision is warranted in patients with radiation induced temporal lobe necrosis with significant symptoms and signs of increased intracranial pressure, minimum space occupying effect on imaging, or neurological deterioration despite conservative management. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  8. Pediatric endocanalicular diode laser dacryocystorhinostomy: results of a minimally invasive surgical technique.

    Science.gov (United States)

    Uysal, Ismail Onder; Ozçimen, Muammer; Yener, Halil Ibrahim; Kal, Ali

    2011-09-01

    The purpose of this study was to evaluate the effectiveness of endocanalicular diode laser dacryocystorhinostomy (DCR), which is a minimally invasive surgical technique, in pediatric patients with congenital nasolacrimal duct obstruction (NLDO). A retrospective study was carried out on patients treated between October 2008 and August 2009 for nasolacrimal duct obstruction with an endocanalicular diode laser procedure. Patients diagnosed as having nasolacrimal duct obstruction were included in this study and an endocanalicular diode laser procedure was performed. The main outcome measures were patients' previous treatments, clinical presentation, operative and postoperative complications, postoperative follow-up and resolution of epiphora. Eighteen children (10 girls, 8 boys) with a mean age of 6.11 ± 2.08 years (range, 4-10) underwent 20 endocanalicular laser DCR operations for congenital NLDO. In all eyes (100%), there was a history of epiphora and chronic dacryocystitis; two (10%) presented with acute dacryocystitis. Previous procedures included probing and irrigation of all eyes (100%) and silicone tube intubation in nine eyes (45%). None of the patients underwent any previous DCR operations. During a mean postoperative follow-up period of 20.50 ± 3.24 months (range, 14-24 months), the anatomical success rate (patency of ostium on nasal endoscopy) was 100%, and the clinical success rate (resolution of epiphora) was 85%. Endocanalicular diode laser DCR is an effective treatment modality for pediatric patients with congenital NLDO that compares favorably with the reported success rates of external and endoscopic endonasal DCR. Moreover, it has an added advantage of shorter operative time, less morbidity and avoidance of overnight admission.

  9. The modified Pirogoff's amputation in treating diabetic foot infections: surgical technique and case series

    Directory of Open Access Journals (Sweden)

    Aziz Nather

    2014-04-01

    Full Text Available Background: This paper describes the surgical technique of a modified Pirogoff's amputation performed by the senior author and reports the results of this operation in a single surgeon case series for patients with diabetic foot infections. Methods: Six patients with diabetic foot infections were operated on by the National University Hospital (NUH diabetic foot team in Singapore between November 2011 and January 2012. All patients underwent a modified Pirogoff's amputation for diabetic foot infections. Inclusion criteria included the presence of a palpable posterior tibial pulse, ankle brachial index (ABI of more than 0.7, and distal infections not extending proximally beyond the midfoot level. Clinical parameters such as presence of pulses and ABI were recorded. Preoperative blood tests performed included a glycated hemoglobin level, hemoglobin, total white blood cell count, C-reactive protein, erythrocyte sedimentation rate, albumin, and creatinine levels. All patients were subjected to 14 sessions of hyperbaric oxygen therapy postoperatively and were followed up for a minimum of 10 months. Results: All six patients had good wound healing. Tibio-calcaneal arthrodesis of the stump was achieved in all cases by 6 months postoperatively. All patients were able to walk with the prosthesis. Conclusions: The modified Pirogoff's amputation has been found to show good results in carefully selected patients with diabetic foot infections. The selection criteria included a palpable posterior tibial pulse, distal infections not extending proximally beyond the midfoot level, ABI of more than 0.7, hemoglobin level of more than 10 g/dL, and serum albumin level of more than 30 g/L.

  10. A novel single-step surgical technique for vestibular deepening using laser in conjunction with periodontal flap surgery

    Directory of Open Access Journals (Sweden)

    Ashu Bhardwaj

    2016-01-01

    Full Text Available Moderate-to-severe chronic periodontitis results in clinical loss of attachment, reduced width of attached gingiva (AG, periodontal pockets beyond mucogingival junction (MGJ, gingival recession, loss of alveolar bone, and decreased vestibular depth (VD. The encroachment of frenal and muscle attachments on marginal gingiva increases the rate of progression of periodontal pockets, prevents healing, and causes their recurrence after therapy. Loss of VD and AG associated with continuous progression of pocket formation and bone loss requires two-stage surgical procedures. In this article, one-stage surgical procedure is being described for the first time, to treat the periodontal pockets extending beyond the MGJ by periodontal flap surgery along with vestibular deepening with diode laser to increase the AG. One-step surgical technique is illustrated whereby pocket therapy with reconstruction of lost periodontal tissues can be done along with gingival augmentation by vestibular deepening.

  11. Para-axillary subcutaneous endoscopic approach in torticollis: tips and tricks in the surgical technique.

    Science.gov (United States)

    Tokar, Baran; Karacay, Safak; Arda, Surhan; Alici, Umut

    2015-04-01

    An obvious scar on the neck may appear following the open surgery for congenital muscular torticollis (CMT). The cosmetic result may displease the patient and the family. In this study, we describe a minimally invasive technique, para-axillary subcutaneous endoscopic approach (PASEA) in CMT. A total of 11 children (seven girls and four boys with the age range between 1 and 15 years) were operated for torticollis by PASEA. All patients had facial asymmetry and head and neck postural abnormality. Following an incision at the ipsilateral para-axillary region, a subcutaneous cavernous working space is formed toward sternocleidomastoid (SCM) muscle. The muscle and fascia are cut by cautery under endoscopic vision. The patients had postoperative 2nd-week and 3rd-month visits. The incision scar, inspection, and palpation findings of the region, head posture, and shoulder position of the affected side were considered in evaluation of the cosmetic outcome. Preoperative and postoperative range of motion of the head and neck were compared for functional outcome. We preferred single incision surgery in our last two patients; the rest had double para-axillary incision for port insertion. Incomplete transection of the muscle was not observed. There was no serious complication. Postoperatively, head posture and shoulder elevation were corrected significantly. Range of motion of the head was improved. Postoperatively, all the patients had rotation capacity with more than 30 degrees. The range of postoperative flexion and extension movements was between 45 and 60 degrees. The open surgery techniques of CMT causes visible lifelong incision scar on the neck. PASEA leaves a cosmetically hidden scar in the axillary region. A single incision surgery is also possible. A well-formed cavernous working space is needed. External manual palpation, delicate dissection, and cutting of SCM muscle with cautery are the important components of the procedure. Surgeons having experience in pediatric

  12. Reducing surgical levels by paraspinal mapping and diffusion tensor imaging techniques in lumbar spinal stenosis

    OpenAIRE

    Chen, Hua-Biao; Wan, Qi; Xu, Qi-Feng; Chen, Yi; Bai, Bo

    2016-01-01

    Background Correlating symptoms and physical examination findings with surgical levels based on common imaging results is not reliable. In patients who have no concordance between radiological and clinical symptoms, the surgical levels determined by conventional magnetic resonance imaging (MRI) and neurogenic examination (NE) may lead to a more extensive surgery and significant complications. We aimed to confirm that whether the use of diffusion tensor imaging (DTI) and paraspinal mapping (PM...

  13. Vaginal-sparing ventral buccal mucosal graft urethroplasty for female urethral stricture: A novel modification of surgical technique.

    Science.gov (United States)

    Hoag, Nathan; Gani, Johan; Chee, Justin

    2016-07-01

    To present a novel modification of surgical technique to treat female urethral stricture (FUS) by a vaginal-sparing ventral buccal mucosal urethroplasty. Recurrent FUS represents an uncommon, though difficult clinical scenario to manage definitively. A variety of surgical techniques have been described to date, yet a lack of consensus on the optimal procedure persists. We present a 51-year-old female with urethral stricture involving the entire urethra. Suspected etiology was iatrogenic from cystoscopy 17 years prior. Since then, the patient had undergone at least 25 formal urethral dilations and periods of self-dilation. In lithotomy position, the urethra was dilated to accommodate forceps, and ventral urethrotomy carried out sharply, exposing a bed of periurethral tissue. Buccal mucosa was harvested, and a ventral inlay technique facilitated by a nasal speculum, was used to place the graft from the proximal urethra/bladder neck to urethral meatus without a vaginal incision. Graft was sutured into place, and urethral Foley catheter inserted. The vaginal-sparing ventral buccal mucosal graft urethroplasty was deemed successful as of last follow-up. Flexible cystoscopy demonstrated patency of the repair at 6 months. At 10 months of follow-up, the patient was voiding well, with no urinary incontinence. No further interventions have been required. This case describes a novel modification of surgical technique for performing buccal mucosal urethroplasty for FUS. By avoiding incision of the vaginal mucosa, benefits may include reduced: morbidity, urinary incontinence, and wound complications including urethro-vaginal fistula.

  14. Surgical extrusion: A reliable technique for saving compromised teeth. A 5-years follow-up case report

    Directory of Open Access Journals (Sweden)

    Jenner Argueta

    2018-06-01

    Full Text Available Aim: To present a long term follow up clinical case in which a compromised anterior tooth was saved by a surgical extrusion procedure. Summary: Although different techniques have been suggested for clinical crown lengthening in the anterior zone, some of them have limitations in terms of aesthetics and procedural requirements. The current case report demonstrates how a simplified surgical extrusion procedure was successfully performed for saving a severely damaged anterior tooth; furthermore, it is possible to apply the technique described in this case using minimum and simple armamentarium like a scalpel, elevators, forceps and splinting flexible cord. Key-learning points: Saving severely compromised anterior teeth is possible by applying surgical extrusion techniques when crown-root ratio allows it. Risk of root resorption or ankylosis is minimum. Riassunto: Obiettivo: Presentare un caso clinico con controllo a 5 anni in cui un dente anteriore compromesso è stato recuperato con una procedura di estrusione chirurgica. Riassunto: Sebbene siano state suggerite diverse tecniche per l’allungamento della corona clinica nella zona anteriore, alcune di esse presentano limitazioni in termini di estetica e competenza nelle procedure. Il presente case report dimostra come una procedura di estrusione chirurgica semplificata sia stata eseguita con successo per salvare un dente anteriore gravemente danneggiato. Va sottolineato che la tecnica descritta in questo caso può essere portata a termine utilizzando un armamentario minimo e molto semplice come un bisturi, leve, pinze e uno splintaggio flessibile. Key learning points: E’ possibile salvare elementi dentari gravemente compromessi applicando tecniche di estrusione chirurgica quando il rapporto corona-radice lo consente. Il rischio di riassorbimento della radice o anchilosi è minimo. Keywords: Crown fracture, Crown lengthening, Surgical extrusion, Surgical repositioning, Biologic width, Parole

  15. The Cost-Effectiveness of Conventional Discectomy Compared to Other Surgical Techniques for Lumbar Disk Herniation. A Systematic Review

    DEFF Research Database (Denmark)

    Thorsen, May Tone; Ødegaard-Olsen, Øystein; Leboeuf-Yde, Charlotte

    2018-01-01

    Background: The current study reviews the literature on the cost-effectiveness of conventional diskectomy compared to other surgical techniques, by assessing studies with economical evaluation and studies using proxy measures of cost-effectiveness. Methods: In April 2016, a comprehensive search w...... studies. The available evidence, however, suggests that any cost-effectiveness difference between conventional diskectomy and the alternatives is unlikely to be great.......Background: The current study reviews the literature on the cost-effectiveness of conventional diskectomy compared to other surgical techniques, by assessing studies with economical evaluation and studies using proxy measures of cost-effectiveness. Methods: In April 2016, a comprehensive search......-four articles were included in the review, 9 retrieved from the original search, and an additional 15 from reference lists. Four studies included an economical evaluation and 20 reported proxy measures of cost-effectiveness. The quality of studies varied considerably and results were ambiguous; the four...

  16. Posterior Surgery for Adolescent Idiopathic Scoliosis With Pedicle Screws and Ultrahigh-Molecular Weight Polyethylene Tape: Achieving the Ideal Thoracic Kyphosis.

    Science.gov (United States)

    Imagama, Shiro; Ito, Zenya; Wakao, Norimitsu; Ando, Kei; Hirano, Kenichi; Tauchi, Ryoji; Muramoto, Akio; Matsui, Hiroki; Matsumoto, Tomohiro; Sakai, Yoshihito; Katayama, Yoshito; Matsuyama, Yukihiro; Ishiguro, Naoki

    2016-10-01

    Prospective clinical case series. To describe our surgical procedure and results for posterior correction and fusion with a hybrid approach using pedicle screws, hooks, and ultrahigh-molecular weight polyethylene tape with direct vertebral rotation (DVR) (the PSTH-DVR procedure) for treatment of adolescent idiopathic scoliosis (AIS) with satisfactory correction in the coronal and sagittal planes. Introduction of segmental pedicle screws in posterior surgery for AIS has facilitated good correction and fusion. However, procedures using only pedicle screws have risks during screw insertion, higher costs, and decreased postoperative thoracic kyphosis. We have obtained good outcomes compared with segmental pedicle screw fixation in surgery for AIS using a relatively simple operative procedure (PSTH-DVR) that uses fewer pedicle screws. The subjects were 30 consecutive patients with AIS who underwent the PSTH-DVR procedure and were followed for a minimum of 2 years. Preoperative flexibility, preoperative and postoperative Cobb angles, correction rates, loss of correction, thoracic kyphotic angles (T5-T12), coronal balance, sagittal balance, and shoulder balance were measured on plain radiographs. Rib hump, operation time, estimated blood loss, spinal cord monitoring findings, complications, and scoliosis research society (SRS)-22 scores were also examined. The mean preoperative curve of 58.0 degrees (range, 40-96 degrees) was corrected to a mean of 9.9 degrees postoperatively, and the correction rate was 83.6%. Fusion was obtained in all patients without loss of correction. In 10 cases with preoperative kyphosis angles (T5-T12) correction of deformity with PSTH-DVR is equivalent to that of all-pedicle screw constructs. The procedure gives favorable correction, is advantageous for kyphosis compared with segmental screw fixation, and uses the minimum number of pedicle screws. Therefore, the PSTH-DVR procedure may be useful for treatment of idiopathic scoliosis.

  17. Clinical experience with a C-section surgical technique in patients with morbid obesity: a case series

    Directory of Open Access Journals (Sweden)

    Mayra Elena Hernández Carrazco

    2014-07-01

    Full Text Available Obesity is a public health challenge that has crossed into the area of reproductive health. An obese pregnant woman has multiple complications before, during, and after pregnancy. Likewise, cesarean section is more difficult and has slower recovery times in this group of patients. This paper proposes a surgical technique adapted to the morbidly obese pregnant patient that aims to reduce cesarean section complications

  18. Development of an adhesive surgical ward round checklist: a technique to improve patient safety.

    LENUS (Irish Health Repository)

    Dhillon, P

    2012-02-01

    Checklists have been shown to improve patient outcomes. Checklist use is seen in the pre-operative to post-operative phases of the patient pathway. An adhesive checklist was developed for ward rounds due to the positive impact it could have on improving patient safety. Over an eight day period data were collected from five consultant-led teams that were randomly selected from the surgical department and divided into sticker groups and control groups. Across the board percentage adherence to the Good Surgical Practice Guidelines (GSPG) was markedly higher in the sticker study group, 1186 (91%) in comparison with the control group 718 (55%). There was significant improvement of documentation across all areas measured. An adhesive checklist for ward round note taking is a simple and cost-effective way to improve documentation, communication, hand-over, and patient safety. Successfully implemented in a tertiary level centre in Dublin, Ireland it is easily transferable to other surgical departments globally.

  19. [Surgical treatment of gynecomastia: an algorithm].

    Science.gov (United States)

    Wolter, A; Scholz, T; Diedrichson, J; Liebau, J

    2013-04-01

    Gynecomastia is a persistent benign uni- or bilateral enlargement of the male breast ranging from small to excessive findings with marked skin redundancy. In this paper we introduce an algorithm to facilitate the selection of the appropriate surgical technique according to the presented morphological aspects. The records of 118 patients (217 breasts) with gynecomastia from 01/2009 to 08/2012 were retrospectively reviewed. The authors conducted three different surgical techniques depending on four severity grades. The outcome parameters complication rate, patient satisfaction with the aesthetic result, nipple sensitivity and the need to re-operate were observed and related to the employed technique. In 167 (77%) breasts with moderate breast enlargement without skin redundancy (Grade I-IIa by Simon's classification) a subcutaneous semicircular periareolar mastectomy was performed in combination with water-jet assisted liposuction. In 40 (18%) breasts with skin redundancy (Grade IIb) a circumferential mastopexy was performed additionally. An inferior pedicled mammaplasty was used in 10 (5%) severe cases (Grade III). Complication rate was 4.1%. Surgical corrections were necessary in 17 breasts (7.8%). The patient survey revealed a high satisfaction level: 88% of the patients rated the aesthetic results as "very good" or "good", nipple sensitivity was rated as "very good" or "good" by 83%. Surgical treatment of gynecomastia should ensure minimal scarring while respecting the aesthetic unit. The selection of the appropriate surgical method depends on the severity grade, the presence of skin redundancy and the volume of the male breast glandular tissue. The presented algorithm rarely leads to complications, is simple to perform and shows a high satisfaction rate and a preservation of the nipple sensitivity. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Transforaminal lumbar interbody fusion using unilateral pedicle screw fixation plus contralateral translaminar facet screw fixation in lumbar degenerative diseases.

    Science.gov (United States)

    Liu, Fubing; Jiang, Chun; Cao, Yuanwu; Jiang, Xiaoxing; Feng, Zhenzhou

    2014-07-01

    Transforaminal lumbar interbody fusion (TLIF) has been used in lumbar degenerative diseases. Some researchers have applied unilateral fixation in TLIF to reduce operational trauma without compromising the clinical outcome, but it is always suspected biomechanically unstable. The supplementary contralateral translaminar facet screw (cTLFS) seemed to be able to overcome the inherent drawbacks of unilateral pedicle screw (uPS) fixation theoretically. This study evaluates the safety, feasibility and efficacy of TLIF using uPS with cTLFS fixation in the treatment of lumbar degenerative diseases (LDD). 50 patients (29 male) underwent the aforementioned surgical technique for their LDD between December 2009 and April 2012. The results were evaluated based on visual analogue scale (VAS) of the leg and back, Japanese Orthopedic Association (JOA) score and Oswestry Disability Index (ODI) were recorded. The radiographic examinations in form of X-ray, computed tomography (CT) or magnetic resonance imaging was done preoperatively and 1 week, 3 months, 6 months, 12 months and 24 months postoperatively. The student t-test was used for comparison between the preoperative values and postoperative counterparts. P degenerative diseases short termly.

  1. Fronto-orbital feminization technique. A surgical strategy using fronto-orbital burring with or without eggshell technique to optimize the risk/benefit ratio.

    Science.gov (United States)

    Villepelet, A; Jafari, A; Baujat, B

    2018-05-04

    The demand for facial feminization is increasing in transsexual patients. Masculine foreheads present extensive supraorbital bossing with a more acute glabellar angle, whereas female foreheads show softer features. The aim of this article is to describe our surgical technique for fronto-orbital feminization. The mask-lift technique is an upper face-lift. It provides rejuvenation by correcting collapsed features, and fronto-orbital feminization through burring of orbital rims and lateral canthopexies. Depending on the size of the frontal sinus and the thickness of its anterior wall, frontal remodeling is achieved using simple burring or by means of the eggshell technique. Orbital remodeling comprises a superolateral orbital opening, a reduction of ridges and a trough at the lateral orbital rim to support the lateral canthopexy. Frontal, corrugator and procerus myectomies, plus minimal scalp excision, complete the surgery. Our technique results in significant, natural-looking feminization. No complications were observed in our series of patients. The eggshell technique is an alternative to bone flap on over-pneumatized sinus. Fronto-orbital feminization fits into a wider surgical strategy. It can be associated to rhinoplasty, genioplasty, mandibular angle remodeling, face lift and laryngoplasty. Achieving facial feminization in 2 or 3 stages improves psychological and physiological tolerance. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  2. Modified frontolateral partial laryngectomy operation: combined muscle-pedicle hyoid bone and thyrohyoid membrane flap in laryngeal reconstruction

    OpenAIRE

    Ouyang, Dian; Liu, Tian-Run; Chen, Yan-Feng; Wang, Jian

    2013-01-01

    Objective Laryngeal reconstruction is needed to preserve laryngeal function in patients who have undergone extensive vertical or frontal partial laryngectomy. However, the procedure remains a difficult challenge. Several reconstruction techniques have been described, but these techniques pose risks of complications such as laryngeal stenosis. This study aimed to evaluate the postoperative course and functional outcomes of a new technique that combined a muscle-pedicle hyoid bone and a thyrohy...

  3. New diagnostic techniques in staging in the surgical treatment of cutaneous malignant melanoma

    NARCIS (Netherlands)

    Cobben, DCP; Koopal, S; Tiebosch, ATMG; Jager, PL; Elsinga, PH; Wobbes, T; Hoekstra, HJ

    2002-01-01

    The emphasis of the research on the surgical treatment of melanoma has been on the resection margins, the role of elective lymph node dissection. in high risk patients and the value of adjuvant regional treatment with hyperthermic isolated lymph perfusion with melphalan. Parallel to this research,

  4. Journal of Surgical Technique and Case Report - Vol 2, No 1 (2010)

    African Journals Online (AJOL)

    Mayer-Rokitansky-Kuster-Hauser syndrome: Surgical management of two cases · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. L.A Mungadi, Y Ahmad, G.H Yunusa, N.P Agwu, S Ismail, 39-43. http://dx.doi.org/10.4103/2006-8808.63725 ...

  5. Blood flow autoregulation in pedicled flaps

    DEFF Research Database (Denmark)

    Bonde, Christian T; Holstein-Rathlou, Niels-Henrik; Elberg, Jens J

    2009-01-01

    was to evaluate if, and to what extent, a tissue flap could compensate a reduction in blood flow due to an acute constriction of the feed artery. Further, we wanted to examine the possible role of smooth muscle L-type calcium channels in the autoregulatory mechanism by pharmacological intervention with the L......, the flow in the pedicle was reduced and the flow was recorded. RESULTS: The flaps showed a strong autoregulatory response with complete compensation for flow reductions of up to 70-80%. Infusion of nimodipine caused a 28+/-10% increase in blood flow and removed the autoregulation. Papaverine caused...... a further increase in blood flow by 61+/-19%. The time control experiments proved that the experimental procedure was reproducible and stable over time. CONCLUSIONS: A tissue flap can nearly completely compensate for repeated flow reductions of up to 70-80%. This is due to a decrease in the peripheral...

  6. Clinical study on the application of minimally invasive percutaneous pedicle screw fixation in single segment thoracolumbar fracture without neurological symptoms

    Directory of Open Access Journals (Sweden)

    Jin-ping LIU

    2016-04-01

    Full Text Available Objective To discuss the clinical effects of minimally invasive percutaneous pedicle screw fixation in the treatment of single segment thoracolumbar fracture without neurological symptoms.  Methods From June 2012 to October 2014, 38 neurologically intact patients with thoracolumbar fracture underwent surgeries, including open pedicle screw fixation in 16 cases and percutaneous pedicle screw fixation in 22 cases. The incision length, operation time, intraoperative blood loss, postoperative drainage and postoperative complication were recorded and compared between 2 groups. Thoracolumbar orthophoric, lateral and flexion-extension X-ray was used to measure sagittal Cobb angle and height of injured anterior vertebral body before and after operation. Modified Macnab evaluation was used to assess the curative effects 3 months after operation. Results The success rate of operations in 38 patients was 100%. There were a total of 114 vertebral bodies fused and 228 pedicle screws implanted. Patients in the percutaneous pedicle screw group had smaller incision length [(10.55 ± 1.23 cm vs (18.50 ± 2.50 cm, P = 0.000], less intraoperative blood loss [(32.55 ± 7.22 ml vs (320.50 ± 15.48 ml, P = 0.000], shorter hospital stay [(6.55 ± 1.50 d vs (13.50 ± 2.52 d, P = 0.000], and without postoperative drainage. The follow-up after operation ranged from 3 to 6 months, with the average time of (4.65 ± 1.24 months. Cobb angle was reduced (P = 0.000 and height of injured anterior vertebral body were improved signifcantly (P = 0.000 3 months after surgery in both groups. The total effective rate was 14/16 in open surgery group, and 86.36% (19/22 in percutaneous pedicle screw group, however, the difference between 2 groups was not significant (P = 1.000. Conclusions Minimally invasive percutaneous pedicle screw fixation is a surgical method with less iatrogenic injury, less intraoperative blood loss and quick recovery for patients with thoracolumbar fracture

  7. A Novel Surgical Technique for Fixation of Recurrent Acromioclavicular Dislocations: AC Dog Bone Technique in Combination with Autogenous Semitendinosus Tendon Graft

    Directory of Open Access Journals (Sweden)

    Patrick Holweg

    2017-01-01

    Full Text Available Various surgical techniques have been described for the fixation of acromioclavicular (AC dislocations. However, recurrent dislocation is one of the main complications associated with the majority of these techniques. We report a case of postoperative AC joint redislocation. In order to overcome recurrent dislocation after revision surgery, a reconstruction of the conoid and trapezoid ligament with the use of a free tendon graft in combination with a FiberTape was provided within a novel surgical technique. After 12 months, the patient was very satisfied with the functional outcome. The patient achieved excellent results in the Constant (98 points, SPADI (0 points, and QuickDASH score (0 points. The described technique results in an anatomic reconstruction of the AC joint. The nonrigid nature of the intervention seems to restore the normal arthrokinematics by reconstructing the coracoclavicular ligaments with an autograft which is then protected by the AC Dog Bone artificial ligaments during the healing period. The arthroscopic approach to the AC joint with minimal exposure reduces the risks and complications of the intervention. This is the first case in literature that utilizes the artificial dog bone ligament securing the autograft in an anatomic AC reconstruction.

  8. Inferior Alveolar Nerve Lateralization and Transposition for Dental Implant Placement. Part I: a Systematic Review of Surgical Techniques

    Directory of Open Access Journals (Sweden)

    Boris Abayev

    2015-03-01

    Full Text Available Objectives: The purpose of this first part of a two-part series was to review the literature concerning the indications, contraindications, advantages, disadvantages and surgical techniques of the lateralization and transposition of the inferior alveolar nerve, followed by the placement of an implant in an edentulous atrophic posterior mandible. Material and Methods: A comprehensive review of the current literature was conducted according to the PRISMA guidelines by accessing the NCBI PubMed and PMC database, academic sites and books. The articles were searched from January 1997 to July 2014 and comprised English-language articles that included adult patients between 18 and 80 years old with minimal residual bone above the mandibular canal who had undergone inferior alveolar nerve (IAN repositioning with a minimum 6 months of follow-up. Results: A total of 16 studies were included in this review. Nine were related to IAN transposition, 4 to IAN lateralization and 3 to both transposition and lateralization. Implant treatment results and complications were presented. Conclusions: Inferior alveolar nerve lateralization and transposition in combination with the installation of dental implants is sometimes the only possible procedure to help patients to obtain a fixed prosthesis, in edentulous atrophic posterior mandibles. With careful pre-operative surgical and prosthetic planning, imaging, and extremely precise surgical technique, this procedure can be successfully used for implant placement in edentulous posterior mandibular segments.

  9. Lumbar pedicle screw placement: Using only AP plane imaging

    Directory of Open Access Journals (Sweden)

    Anil Sethi

    2012-01-01

    Conclusion: Placement of pedicle screws under fluoroscopic guidance using AP plane imaging alone with tactile guidance is safe, fast, and reliable. However, a good understanding of the radiographic landmarks is a prerequisite.

  10. Omental pedicle transposition and suture repair of peripheral nerve ...

    African Journals Online (AJOL)

    Abu wael

    This study aimed to compare the effectiveness of omental pedicle transposition and ... Assessment of the nerve regeneration was based on functional (motor and sensory), ..... peripheral nerve fibers regenerating after crush, multiple crush, and.

  11. Technique of Antireflux Procedure without Creating Submucosal Tunnel for Surgical Correction of Vesicoureteric Reflux during Bladder Closure in Exstrophy.

    Science.gov (United States)

    Sunil, Kanoujia; Gupta, Archika; Chaubey, Digamber; Pandey, Anand; Kureel, Shiv Narain; Verma, Ajay Kumar

    2018-01-01

    To report the clinical application of the new surgical technique of antireflux procedure without creating submucosal tunnel for surgical correction of vesicoureteric reflux during bladder closure in exstrophy. Based on the report of published experimental technique, the procedure was clinically executed in seven patients of classic exstrophy bladder with small bladder plate with polyps, where the creation of submucosal tunnel was not possible, in last 18 months. Ureters were mobilized. A rectangular patch of bladder mucosa at trigone was removed exposing the detrusor. Mobilized urteres were advanced, crossed and anchored to exposed detrusor parallel to each other. Reconstruction included bladder and epispadias repair with abdominal wall closure. The outcome was measured with the assessment of complications, abolition of reflux on cystogram and upper tract status. At 3-month follow-up cystogram, reflux was absent in all. Follow-up ultrasound revealed mild dilatation of pelvis and ureter in one. The technique of extra-mucosal ureteric reimplantation without the creation of submucosal tunnel is simple to execute without risk and complications and effectively provides an antireflux mechanism for the preservation of upper tract in bladder exstrophy. With the use of this technique, reflux can be prevented since the very beginning of exstrophy reconstruction.

  12. Robotic-assisted partial nephrectomy: surgical technique using a 3-arm approach and sliding-clip renorrhaphy

    Directory of Open Access Journals (Sweden)

    Jose M. Cabello

    2009-04-01

    Full Text Available INTRODUCTION: For the treatment of renal tumors, minimally invasive nephron-sparing surgery has become increasingly performed due to proven efficiency and excellent functional and oncological outcomes. The introduction of robotics into urologic laparoscopic surgery has allowed surgeons to perform challenging procedures in a reliable and reproducible manner. We present our surgical technique for robotic assisted partial nephrectomy (RPN using a 3-arm approach, including a sliding-clip renorrhaphy. MATERIAL AND METHODS: Our RPN technique is presented which describes the trocar positioning, hilar dissection, tumor identification using intraoperative ultrasound for margin determination, selective vascular clamping, tumor resection, and reconstruction using a sliding-clip technique. CONCLUSION: RPN using a sliding-clip renorrhaphy is a valid and reproducible surgical technique that reduces the challenge of the procedure by taking advantage of the enhanced visualization and control afforded by the robot. The renorrhaphy described is performed under complete control of the console surgeon, and has demonstrated a reduction in the warm ischemia times in our series.

  13. The management of thoracic inlet syndrome associated with Hurler's syndrome: a novel surgical technique.

    LENUS (Irish Health Repository)

    Ahsan, Rauf M

    2012-02-01

    A 21-year-old male developed significant swelling of his tongue after a respiratory arrest. The patient had a history of Hurler\\'s syndrome. Magnetic resonance imaging (MRI) angiogram delineated that the swelling was due to compression of his internal jugular veins at the level of the first rib, resulting in thoracic inlet obstruction. The standard surgical treatment of thoracic inlet obstruction was not suitable in this patient\\'s case due to his short thick neck and his characteristic Hurler\\'s syndrome body habitus. Therefore, a novel surgical strategy was used to decompress his head and neck vessels. The manubrium was widened using an iliac crest bone graft, stabilised using internal fixation plates and reconstructed with a pectoral muscle flap.

  14. Duodenum preserving pancreatectomy in chronic pancreatitis: Design of a randomized controlled trial comparing two surgical techniques [ISRCTN50638764

    Directory of Open Access Journals (Sweden)

    Reidel Margot A

    2006-05-01

    Full Text Available Abstract Background Chronic pancreatitis is an inflammatory disease which is characterized by an irreversible conversion of pancreatic parenchyma to fibrous tissue. Beside obstructive jaundice and pseudocyst formation, about half of the patients need surgical intervention due to untreatable chronic pain during the course of the disease. In most of the patients with chronic pancreatitis, the head of the pancreas is the trigger of the chronic inflammatory process. Therefore, resection of pancreatic head tissue must be the central part of any surgical intervention. However, it is unclear to which extent the surgical procedure must be radical in order to obtain a favourable outcome for the patients. Design A single centre randomized controlled, superiority trial to compare two techniques of duodenum preserving pancreatic head resection. Sample size: 65 patients will be included and randomized intraoperatively. Eligibility criteria: All patients with chronic pancreatitis and indication for surgical resection and signed informed consent. Cumulative primary endpoint (hierarchical model: duration of surgical procedure, quality of life after one year, duration of intensive care unit stay, duration of hospital stay. Reference treatment: Resection of the pancreatic head with dissection of the pancreas from the portal vein and transsection of the gland (Beger procedure. Intervention: Partial Resection of the pancreatic head without transsection of the organ and visualization of the portal vein (Berne procedure. Duration: September 2003-October 2007. Organisation/responsibility The trial is conducted in compliance with the protocol and in accordance with the moral, ethical, regulatory and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989 and the Good Clinical Practice guideline (GCP. The Center for Clinical Studies of the Department of Surgery Heidelberg is responsible for planning, conducting and final

  15. Visualization and simulation techniques for surgical simulators using actual patient's data.

    Science.gov (United States)

    Radetzky, Arne; Nürnberger, Andreas

    2002-11-01

    Because of the increasing complexity of surgical interventions research in surgical simulation became more and more important over the last years. However, the simulation of tissue deformation is still a challenging problem, mainly due to the short response times that are required for real-time interaction. The demands to hard and software are even larger if not only the modeled human anatomy is used but the anatomy of actual patients. This is required if the surgical simulator should be used as training medium for expert surgeons rather than students. In this article, suitable visualization and simulation methods for surgical simulation utilizing actual patient's datasets are described. Therefore, the advantages and disadvantages of direct and indirect volume rendering for the visualization are discussed and a neuro-fuzzy system is described, which can be used for the simulation of interactive tissue deformations. The neuro-fuzzy system makes it possible to define the deformation behavior based on a linguistic description of the tissue characteristics or to learn the dynamics by using measured data of real tissue. Furthermore, a simulator for minimally-invasive neurosurgical interventions is presented that utilizes the described visualization and simulation methods. The structure of the simulator is described in detail and the results of a system evaluation by an experienced neurosurgeon--a quantitative comparison between different methods of virtual endoscopy as well as a comparison between real brain images and virtual endoscopies--are given. The evaluation proved that the simulator provides a higher realism of the visualization and simulation then other currently available simulators. Copyright 2002 Elsevier Science B.V.

  16. Robotic-assisted transperitoneal nephron-sparing surgery for small renal masses with associated surgical procedures: surgical technique and preliminary experience.

    Science.gov (United States)

    Ceccarelli, Graziano; Codacci-Pisanelli, Massimo; Patriti, Alberto; Ceribelli, Cecilia; Biancafarina, Alessia; Casciola, Luciano

    2013-09-01

    Small renal masses (T1a) are commonly diagnosed incidentally and can be treated with nephron-sparing surgery, preserving renal function and obtaining the same oncological results as radical surgery. Bigger lesions (T1b) may be treated in particular situations with a conservative approach too. We present our surgical technique based on robotic assistance for nephron-sparing surgery. We retrospectively analysed our series of 32 consecutive patients (two with 2 tumours and one with 4 bilateral tumours), for a total of 37 robotic nephron-sparing surgery (RNSS) performed between June 2008 and July 2012 by a single surgeon (G.C.). The technique differs depending on tumour site and size. The mean tumour size was 3.6 cm; according to the R.E.N.A.L. Nephrometry Score 9 procedures were considered of low, 14 of moderate and 9 of hight complexity with no conversion in open surgery. Vascular clamping was performed in 22 cases with a mean warm ischemia time of 21.5 min and the mean total procedure time was 149.2 min. Mean estimated blood loss was 187.1 ml. Mean hospital stay was 4.4 days. Histopathological evaluation confirmed 19 cases of clear cell carcinoma (all the multiple tumours were of this nature), 3 chromophobe tumours, 1 collecting duct carcinoma, 5 oncocytomas, 1 leiomyoma, 1 cavernous haemangioma and 2 benign cysts. Associated surgical procedures were performed in 10 cases (4 cholecystectomies, 3 important lyses of peritoneal adhesions, 1 adnexectomy, 1 right hemicolectomy, 1 hepatic resection). The mean follow-up time was 28.1 months ± 12.3 (range 6-54). Intraoperative complications were 3 cases of important bleeding not requiring conversion to open or transfusions. Regarding post-operative complications, there were a bowel occlusion, 1 pleural effusion, 2 pararenal hematoma, 3 asymptomatic DVT (deep vein thrombosis) and 1 transient increase in creatinine level. There was no evidence of tumour recurrence in the follow-up. RNSS is a safe and feasible technique

  17. Vaginal-sparing ventral buccal mucosal graft urethroplasty for female urethral stricture: A novel modification of surgical technique

    Directory of Open Access Journals (Sweden)

    Nathan Hoag

    2016-07-01

    Full Text Available Purpose: To present a novel modification of surgical technique to treat female urethral stricture (FUS by a vaginal-sparing ventral buccal mucosal urethroplasty. Recurrent FUS represents an uncommon, though difficult clinical scenario to manage definitively. A variety of surgical techniques have been described to date, yet a lack of consensus on the optimal procedure persists. Materials and Methods: We present a 51-year-old female with urethral stricture involving the entire urethra. Suspected etiology was iatrogenic from cystoscopy 17 years prior. Since then, the patient had undergone at least 25 formal urethral dilations and periods of self-dilation. In lithotomy position, the urethra was dilated to accommodate forceps, and ventral urethrotomy carried out sharply, exposing a bed of periurethral tissue. Buccal mucosa was harvested, and a ventral inlay technique facilitated by a nasal speculum, was used to place the graft from the proximal urethra/bladder neck to urethral meatus without a vaginal incision. Graft was sutured into place, and urethral Foley catheter inserted. Results: The vaginal-sparing ventral buccal mucosal graft urethroplasty was deemed successful as of last follow-up. Flexible cystoscopy demonstrated patency of the repair at 6 months. At 10 months of follow-up, the patient was voiding well, with no urinary incontinence. No further interventions have been required. Conclusions: This case describes a novel modification of surgical technique for performing buccal mucosal urethroplasty for FUS. By avoiding incision of the vaginal mucosa, benefits may include reduced: morbidity, urinary incontinence, and wound complications including urethro-vaginal fistula.

  18. MIS Single-position Lateral and Oblique Lateral Lumbar Interbody Fusion and Bilateral Pedicle Screw Fixation: Feasibility and Perioperative Results.

    Science.gov (United States)

    Blizzard, Daniel J; Thomas, J Alex

    2018-03-15

    Retrospective review of prospectively collected data of the first 72 consecutive patients treated with single-position one- or two-level lateral (LLIF) or oblique lateral interbody fusion (OLLIF) with bilateral percutaneous pedicle screw and rod fixation by a single spine surgeon. To evaluate the clinical feasibility, accuracy, and efficiency of a single-position technique for LLIF and OLLIF with bilateral pedicle screw and rod fixation. Minimally-invasive lateral interbody approaches are performed in the lateral decubitus position. Subsequent repositioning prone for bilateral pedicle screw and rod fixation requires significant time and resources and does not facilitate increased lumbar lordosis. The first 72 consecutive patients (300 screws) treated with single-position LLIF or OLLIF and bilateral pedicle screws by a single surgeon between December 2013 and August 2016 were included in the study. Screw accuracy and fusion were graded using computed tomography and several timing parameters were recorded including retractor, fluoroscopy, and screw placement time. Complications including reoperation, infection, and postoperative radicular pain and weakness were recorded. Average screw placement time was 5.9 min/screw (standard deviation, SD: 1.5 min; range: 3-9.5 min). Average total operative time (interbody cage and pedicle screw placement) was 87.9 minutes (SD: 25.1 min; range: 49-195 min). Average fluoroscopy time was 15.0 s/screw (SD: 4.7 s; range: 6-25 s). The pedicle screw breach rate was 5.1% with 10/13 breaches measured as < 2 mm in magnitude. Fusion rate at 6-months postoperative was 87.5%. Two (2.8%) patients underwent reoperation for malpositioned pedicle screws with subsequent resolution of symptoms. The single-position, all-lateral technique was found to be feasible with accuracy, fluoroscopy usage, and complication rates comparable with the published literature. This technique eliminates the time and staffing associated with

  19. Transvaginal Cystocele Repair by Purse-String Technique Reinforced with Three Simple Sutures: Surgical Technique and Results

    Directory of Open Access Journals (Sweden)

    Ho-Sook Song

    2012-09-01

    Full Text Available Purpose Different techniques for cystocele repair including the conventional anterior colporrhaphy and mesh technique are known. Our goal was to evaluate the anatomical success and safety of our method of transvaginal anterior vaginal wall repair by the purse-string technique reinforced with three simple additional sutures in the repair of cystocele over a 4-year follow-up period. Methods This was a retrospective review of 69 consecutive patients (grades 2 to 4 who underwent the above operations between 2001 and 2011, including their success rates as assessed by use of the Baden-Walker halfway classification system. Results Of the patients, 62 patients (98% were completely cured of cystocele and 1 patient showed grade 2 cystocele recurrence that required no further treatment. Two patients with grade 4 cystocele were completely cured. There was no vaginal erosion related to the cystocele repair. Conclusions Transvaginal anterior colporrhaphy by a purse-string technique reinforced with simple additive sutures appears to be a simple, safe, and easily performed approach in cystocele repair. There is no need for other material for reinforcement, even in high-grade cystocele, which is an advantage of our technique.

  20. Three-Year Outcome of Fixed Partial Rehabilitations Supported by Implants Inserted with Flap or Flapless Surgical Techniques.

    Science.gov (United States)

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando

    2016-07-01

    The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when

  1. A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases

    Science.gov (United States)

    Chen, Xiong-sheng; Zhou, Sheng-yuan; Jia, Lian-shun; Gu, Xiao-min; Fang, Lei; Zhu, Wei

    2013-01-01

    Objective To investigate the surgical outcome of a universal pedicle screw-V rod system and isthmic bone grafting for isthmic spondylolysis. Methods Twenty-four patients with isthmic spondylolysis at L5 and grade 0–I spondylolisthesis (Meyerding classification) received isthmic bone graft and stabilization using the universal pedicle screw-V rod system. Back pain was evaluated using the visual analog scale (VAS) and time to bone healing, improvement in spondylolisthesis and intervertebral space height at L5/S1 and L4/L5 were assessed. Results Twenty-one patients were followed up for 24 months and included in the analysis. Back pain was markedly improved at 3 months postoperatively with a statistical difference in VAS scores compared with preoperative VAS scores (Pspondylolysis and reduces back pain, prevents anterior displacement of the diseased segment and maintains intervertebral space height, thus offering a promising alternative to current approaches for isthmic spondylolysis. PMID:23691090

  2. Posterior Rigid Instrumentation of C7: Surgical Considerations and Biomechanics at the Cervicothoracic Junction. A Review of the Literature.

    Science.gov (United States)

    Bayoumi, Ahmed B; Efe, Ibrahim E; Berk, Selim; Kasper, Ekkehard M; Toktas, Zafer Orkun; Konya, Deniz

    2018-03-01

    The cervicothoracic junction is a challenging anatomic transition in spine surgery. It is commonly affected by different types of diseases that may significantly impair stability in this region. The seventh cervical vertebra (C7) is an atypical cervical vertebra with unique anatomic features compared to subaxial cervical spine (C3 to C6). C7 has relatively broader laminae, larger pedicles, smaller lateral masses, and a long nonbifid spinous process. These features allow a variety of surgical methods for performing posterior rigid instrumentation in the form of different types of screws, such as lateral mass screws, pedicle screws, transfacet screws, and intralaminar screws. Many biomechanical studies on cadavers have evaluated and compared different types of implants at C7. We reviewed PubMed/Medline by using specific combinations of keywords to summarize previously published articles that examined C7 posterior rigid instrumentation thoroughly in an experimental fashion on patients or cadavers with additional descriptive radiologic parameters for evaluation of the optimum surgical technique for each type. A total of 44 articles were reported, including 22 articles that discussed anatomic considerations (entry points, sagittal and axial trajectories, and features of screws) and another 22 articles that discussed the relevant biomechanical testing at this transitional region if C7 was directly involved in terms of receiving posterior rigid implants. C7 can accommodate different types of screws, which can provide additional benefits and risks based on availability of bony purchase, awareness of surgical technique, biomechanics, and anatomic considerations. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Comparison of Expansive Pedicle Screw and Polymethylmethacrylate-Augmented Pedicle Screw in Osteoporotic Sheep Lumbar Vertebrae: Biomechanical and Interfacial Evaluations

    OpenAIRE

    Liu, Da; Zhang, Yi; Zhang, Bo; Xie, Qing-yun; Wang, Cai-ru; Liu, Jin-biao; Liao, Dong-fa; Jiang, Kai; Lei, Wei; Pan, Xian-ming

    2013-01-01

    BACKGROUND: It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. METHODOLOGY/PRINCIPAL FINDINGS: After successful induction of osteoporotic sheep, lumbar vertebrae in each sheep were random...

  4. Assessment of resectability of pancreatic cancer with dynamic contrast-enhanced MR imaging: technique, surgical correlation and patient outcome

    International Nuclear Information System (INIS)

    Spencer, J.A.; Ward, J.; Guthrie, J.A.; Robinson, P.J.A.; Guillou, P.J.

    1998-01-01

    The aim of our work was to investigate the use of a dynamic contrast-enhanced MR (DCEMR) technique for staging apparently localised pancreatic cancer, and to determine the patterns of tumour and vascular enhancement with this technique. Thirty-five consecutive patients were examined. The MR findings were correlated with surgical findings in 13 patients and with clinical outcome in 22 patients. Breath-hold gradient-echo fast low angle shot (TR = 100, TE = 4, flip angle 80 ) acquisitions were obtained at 10 and 40 s (right anterior coronal oblique plane) and at 90 s (axial plane) following intravenous gadolinium. Mean contrast-to-noise ratio was higher on the first than the second acquisition (p < 0.001) and higher on the second acquisition than the third (p < 0.005). Tumour conspicuity was greatest and arterial anatomy was best demonstrated on the first acquisition and the portal venous anatomy on the second. Small tumours were isointense by the third acquisition. Maximal intensity projections were helpful. The MR findings correctly predicted the surgical findings in 11 of 13 cases (85 %) and the clinical course in the other 22 patients. The DCEMR imaging technique is valuable in the staging of patients with pancreatic cancer. Capillary and portal venous phase images are both required for complete local staging. (orig.)

  5. Bilateral sacroiliac luxation fixation using a single transiliosacral pin: surgical technique and clinical outcomes in eight cats.

    Science.gov (United States)

    Parslow, A; Simpson, D J

    2017-06-01

    A very limited safe anatomical window for transiliosacral implant placement exists in cats (sacroiliac fixation in cats using a single implant to minimise inadvertent iatrogenic damage to local structures and restore pelvic canal diameter. Eight cats underwent surgical fixation for traumatic bilateral sacroiliac luxation using a single smooth intramedullary pin. The pin spanned both ilial wings and sacrum. Implants were applied using a Universal C-guide. Pre- and postsurgery pelvic canal diameter ratios were calculated. Short-term follow-up was performed at 10 to 14 days postoperatively. Long-term follow-up was performed using the Feline Musculoskeletal Pain Index Questionnaire. Long-term radiographic assessment was available in two cases. The technique achieved safe and accurate implant position with precise sacroiliac joint reduction. Pelvic canal diameter ratios were restored to normal in all cases. Rapid return to normal hind leg function and excellent long-term clinical outcomes were achieved. This technique offers a simple, safe, repeatable and affordable technique for treating bilateral sacroiliac luxations in the cat without the aid of fluoroscopy. The procedure can be performed using surgical tools and inventory readily available in general small animal practices. © 2017 British Small Animal Veterinary Association.

  6. Transanal endoscopic microsurgery as technique surgical for the treatment of the rectal adenocarcinoma: history, evolution and current tendency

    International Nuclear Information System (INIS)

    Vega Padilla, Luis Carlos

    2013-01-01

    The modalities of local and minimally invasive treatment were described for early rectal adenocarcinomas. The most adequate diagnostic studies and interdisciplinary interactions involved were considered in the process and the therapeutic results, in comparison with the current radical treatments. The historical evolution of the different surgical techniques developed over time, and the anatomical and physiological concepts were reviewed. The epidemiological behavior of the disease was documented according to gender, age and most prevalent sites to direct the possible risk groups to suffer the disease. Risk factors that affect patients with colorectal cancer were identified and related to the environment, social habits and hereditary. The different genetic syndromes involved in colorectal cancer, its physiopathology and clinical manifestations and implications were examined with respect to colorectal cancer. Colorectal cancer was defined according to the updated classifications of the American Joint Cancer Committee, according to the depth, affectation of lymph nodes and metastasis to distant organs, in relation to its clinical stage. Current surgical techniques were named to treat early adenocarcinomas of inferior rectus. The different risk factors were analyzed to allow local resections of the early rectal tumors, from the histopalogical, radiological and clinical point of view. The traditional techniques of transanal and radical resection were compared against the transanal endoscopic microsurgery between different aspects such as technical difficulty, recurrence rate, morbidity and mortality, and economic cost [es

  7. Fixation of Hydroxyapatite-Coated Revision Implants Is Improved by the Surgical Technique of Cracking the Sclerotic Bone Rim

    Science.gov (United States)

    Elmengaard, Brian; Bechtold, Joan E.; Chen, Xinqian; Søballe, Kjeld

    2013-01-01

    Revision joint replacement has poorer outcomes that have been associated with poorer mechanical fixation. We investigate a new bone-sparing surgical technique that locally cracks the sclerotic bone rim formed during aseptic loosening. We inserted 16 hydroxyapatite-coated implants bilaterally in the distal femur of eight dogs, using a controlled weight-bearing experimental model that replicates important features of a typical revision setting. At 8 weeks, a control revision procedure and a crack revision procedure were performed on contralateral implants. The crack procedure used a splined tool to perform a systematic local perforation of the sclerotic bone rim of the revision cavity. After 4 weeks, the hydroxyapatite-coated implants were evaluated for mechanical fixation by a push-out test and for tissue distribution by histomorphometry. The cracking revision procedure resulted in significantly improved mechanical fixation, significantly more bone ongrowth and bone volume in the gap, and reduced fibrous tissue compared to the control revision procedure. The study demonstrates that the sclerotic bone rim prevents bone ingrowth and promotes fixation by fibrous tissue. The effect of the cracking technique may be due to improved access to the vascular compartment of the bone. The cracking technique is a simple surgical method that potentially can improve the fixation of revision implants in sclerotic regions important for obtaining the fixation critical for overall implant stability. PMID:19148940

  8. Efficacy of surgical techniques and factors affecting residual stone rate in the treatment of kidney stones.

    Science.gov (United States)

    Aydemir, Hüseyin; Budak, Salih; Kumsar, Şükrü; Köse, Osman; Sağlam, Hasan Salih; Adsan, Öztuğ

    2014-09-01

    In this study, we aimed to evaluate, the efficacy of surgical methods and the factors affecting the residual stone rate by scrutinizing retrospectively the patients who had undergone renal stone surgery. Records of 109 cases of kidney stones who had been surgically treated between January 2010, and July 2013 were reviewed. Patients were divided into three groups in terms of surgical treatment; open stone surgery, percutaneous nephrolithotomy (PNL) and retrograde intrarenal surgery (RIRS). Patients' history, physical examination, biochemical and radiological images and operative and postoperative data were recorded. The patients had undergone PNL (n=74; 67.9%), RIRS (n=22;20.2%), and open renal surgery (n=13; 11.9%). The mean and median ages of the patients were 46±9, 41 (21-75) and, 42 (23-67) years, respectively. The mean stone burden was 2.6±0.7 cm(2) in the PNL, 1.4±0.1 cm(2) in the RIRS, and 3.1±0.9 cm(2) in the open surgery groups. The mean operative times were 126±24 min in the PNL group, 72±12 min in the RIRS group and 82±22 min in the open surgery group. The duration of hospitalisation was 3.1±0.2 days, 1.2±0.3 days and 3.4±1.1 days respectively. While the RIRS group did not need blood transfusion, in the PNL group blood transfusions were given in the PNL (n=18), and open surgery (n=2) groups. Residual stones were detected in the PNL (n=22), open surgery (n=2), and RIRS (n=5) groups. PNL and RIRS have been seen as safe and effective methods in our self application too. However, it should not be forgotten that as a basical method, open surgery may be needed in cases of necessity.

  9. Surgical closure of persistent arterial duct with minimal invasive anterior thoracotomy: an alternative technique.

    Science.gov (United States)

    Fouilloux, Virginie; Gran, Célia; Kreitmann, Bernard

    2014-10-01

    Surgical approach for persistent ductus arteriosus ligation is typically a left lateral thoracotomy opening the pleural-space with left lung retraction. We describe an alternative approach, with a minimally invasive anterior parasternal incision. This is particularly adapted to preterm infants weighing less than 1.5 kg. This approach ensures a good exposure of vessels. We believe that it is safe, reliable and reproducible. The learning curve should not be an issue for surgeons used to manage low weight patients. Georg Thieme Verlag KG Stuttgart · New York.

  10. [Surgical issues and outcomes in ischial pressure sores treatment].

    Science.gov (United States)

    Voulliaume, D; Grecea, M; Viard, R; Brun, A; Comparin, J-P; Foyatier, J-L

    2011-12-01

    Ischiatic pressure sores are frequent in spinal cord injury patients, associated with bad prognosis and high recurrence rate. Many surgical techniques were described, including surgical debridement followed by pedicled flap coverage. We aim to propose a practical decision tree for primary or secondary ischial pressure sore treatment. Our series of 48 operated ischial sores with an average follow up of 4 years (range 2 to 8years) is analyzed and compared to previously published reports. Surgical techniques are discussed according to their specific indications. The optimal recurrence rate in published reports about pressure sore treatment is 20%; a rate inferior to 19% is found in our series, showing the equal importance of flap selection and postoperative care and education. Depending on each situation, various available flaps are described and compared: gluteus maximus flap, biceps femoris flap, gracilis flap, tensor fascia lata flap, fasciocutaneous thigh flaps, rectus femoris and vastus lateralis flap, rectus abdominis flap. Specific surgical indications for more extensive wounds are studied: resection arthroplasty of the hip, hip disarticulation, fillet flaps from the leg, microsurgery. Based upon our experience, a decision tree summarizes our proposition of flap selection, depending on the wound size and the patient background. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  11. Static antibiotic spacers augmented by calcium sulphate impregnated beads in revision TKA: Surgical technique and review of literature.

    Science.gov (United States)

    Risitano, Salvatore; Sabatini, Luigi; Atzori, Francesco; Massè, Alessandro; Indelli, Pier Francesco

    2018-06-01

    Periprosthetic joint infection (PJI) is a serious complication in total knee arthroplasty (TKA) and represents one of the most common causes of revision. The challenge for surgeons treating an infected TKA is to quickly obtain an infection-free joint in order to re-implant, when possible, a new TKA. Recent literature confirms the role of local antibiotic-loaded beads as a strong bactericidal, allowing higher antibiotic elution when compared with antibiotic loaded spacers only. Unfortunately, classical Polymethylmethacrylate (PMMA) beads might allow bacteria adhesion, secondary development of antibiotic resistance and eventually surgical removal once antibiotics have eluted. This article describes a novel surgical technique using static, custom-made antibiotic loaded spacers augmented by calcium sulphate antibiotic-impregnated beads to improve the success rate of revision TKA in a setting of PJI. The use of calcium sulphate beads has several potential benefits, including a longer sustained local antibiotic release when compared with classical PMMA beads and, being resorbable, not requiring accessory surgical interventions.

  12. “A Tree Must Be Bent While It Is Young”: Teaching Urological Surgical Techniques to Schoolchildren

    Science.gov (United States)

    Buntrock, Stefan

    2012-01-01

    Background Playing video games in childhood may help achieve advanced laparoscopic skills later in life. The virtual operating room will soon become a reality, as “doctor games 2.0” will doubtlessly begin to incorporate virtual laparoscopic techniques. Objectives To teach surgical skills to schoolchildren in order to attract them to urology as a professional choice later in life. Materials and Methods As part of EAU Urology Week 2010, 108 school children aged 15–19 attended a seminar with lectures and simulators (laparoscopy, TUR, cystoscopy, and suture sets) at the 62nd Congress of the German Society of Urology in Düsseldorf. A Pub-Med and Google Scholar search was also performed in order to review the beneficial effects of early virtual surgical training. MeSh terms used were “video games,” “children,” and “surgical skills.” Searches were performed without restriction for a certain period of time. Results In terms of publicity for urology, EAU Urology Week, and the German Society of Urology, the event was immensely successful. Regarding the literature search, four relevant publications were found involving children. An additional three articles evaluated the usefulness of video gaming in medical students and residents. Conclusions Making use of virtual reality to attract and educate a new generation of urologists is an important step in designing the future of urology. PMID:23573467

  13. Surgical management of peptic ulcer disease today--indication, technique and outcome.

    Science.gov (United States)

    Zittel, T T; Jehle, E C; Becker, H D

    2000-03-01

    The current surgical management of peptic ulcer disease and its outcome have been reviewed. Today, surgery for peptic ulcer disease is largely restricted to the treatment of complications. In peptic ulcer perforation, a conservative treatment trial can be given in selected cases. If laparotomy is necessary, simple closure is sufficient in the large majority of cases, and definitive ulcer surgery to reduce gastric acid secretion is no longer justified in these patients. Laparoscopic surgery for perforated peptic ulcer has failed to prove to be a significant advantage over open surgery. In bleeding peptic ulcers, definitive hemostasis can be achieved by endoscopic treatment in more than 90% of cases. In 1-2% of cases, immediate emergency surgery is necessary. Some ulcers have a high risk of re-bleeding, and early elective surgery might be advisable. Surgical bleeding control can be achieved by direct suture and extraluminal ligation of the gastroduodenal artery or by gastric resection. Benign gastric outlet obstruction can be controlled by endoscopic balloon dilatation in 70% of cases, but gastrojejunostomy or gastric resection are necessary in about 30% of cases. Elective surgery for peptic ulcer disease has been largely abandoned, and bleeding or obstructing ulcers can be managed safely by endoscopic treatment in most cases. However, surgeons will continue to encounter patients with peptic ulcer disease for emergency surgery. Currently, laparoscopic surgery has no proven advantage in peptic ulcer surgery.

  14. Repair of Total Tractional Retinal Detachment in Norrie Disease: Report of Technique and Successful Surgical Outcome.

    Science.gov (United States)

    Todorich, Bozho; Thanos, Aristomenis; Yonekawa, Yoshihiro; Capone, Antonio

    2017-03-01

    Norrie disease is a rare, but devastating cause of pediatric retinal detachment, universally portending a poor visual prognosis. This paper describes successful surgical management of an infant with total retinal detachment associated with Norrie disease mutation. The infant was a full-term white male who presented with bilateral total funnel retinal detachments (RDs). He underwent genetic testing, which demonstrated single-point mutation 133 G>A transition in exon 2 of the NDP gene. The retinal detachment was managed with translimbal iridectomy, lensectomy, capsulectomy, and vitrectomy. Careful dissection of the retrolental membranes resulted in opening of the funnel. Single-stage surgery in this child's eye achieved re-attachment of the posterior pole with progressive reabsorption of subretinal fluid and cholesterol without the need for external drainage. Fluorescein angiography, performed at 2 months postoperatively, demonstrated perfusion of major vascular arcades, but with significant abnormalities and aneurysmal changes of higher-order vessels, suggestive of retinal and vascular dysplasia. The child has maintained brisk light perception vision. Early surgical intervention with careful dissection of tractional tissues can potentially result in good anatomic outcomes in some patients with Norrie disease-associated retinal detachment. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:260-262.]. Copyright 2017, SLACK Incorporated.

  15. Creation of a Bioengineered Skin Flap Scaffold with a Perfusable Vascular Pedicle.

    Science.gov (United States)

    Jank, Bernhard J; Goverman, Jeremy; Guyette, Jacques P; Charest, Jon M; Randolph, Mark; Gaudette, Glenn R; Gershlak, Joshua R; Purschke, Martin; Javorsky, Emilia; Nazarian, Rosalynn M; Leonard, David A; Cetrulo, Curtis L; Austen, William G; Ott, Harald C

    2017-07-01

    Full-thickness skin loss is a challenging problem due to limited reconstructive options, demanding 75 million surgical procedures annually in the United States. Autologous skin grafting is the gold standard treatment, but results in donor-site morbidity and poor aesthetics. Numerous skin substitutes are available on the market to date, however, none truly functions as full-thickness skin due to lack of a vascular network. The creation of an autologous full-thickness skin analogue with a vascular pedicle would result in a paradigm shift in the management of wounds and in reconstruction of full-thickness skin defects. To create a clinically relevant foundation, we generated an acellular skin flap scaffold (SFS) with a perfusable vascular pedicle of clinically relevant size by perfusion decellularization of porcine fasciocutaneous flaps. We then analyzed the yielded SFS for mechanical properties, biocompatibility, and regenerative potential in vitro and in vivo. Furthermore, we assessed the immunological response using an in vivo model. Finally, we recellularized the vascular compartment of an SFS and reconnected it to a recipient's blood supply to test for perfusability. Perfusion decellularization removed all cellular components with preservation of native extracellular matrix composition and architecture. Biaxial testing revealed preserved mechanical properties. Immunologic response and biocompatibility assessed via implantation and compared with native xenogenic skin and commercially available dermal substitutes revealed rapid neovascularization and complete tissue integration. Composition of infiltrating immune cells showed no evidence of allorejection and resembled the inflammatory phase of wound healing. Implantation into full-thickness skin defects demonstrated good tissue integration and skin regeneration without cicatrization. We have developed a protocol for the generation of an SFS of clinically relevant size, containing a vascular pedicle, which can be

  16. Orange Peel Excision of Gland: A Novel Surgical Technique for Treatment of Gynecomastia.

    Science.gov (United States)

    S S, Shirol

    2016-12-01

    Gynecomastia is a common aesthetic problem faced by men with reported incidence as high as 65% with serious psychosocial impact. Although various techniques of liposculpture combined with glandular excision is the standard of treatment, many of the glandular excision techniques have inherent limitations and complications such as leaving a long scar, long operative time, contour abnormalities, and increased risk of hematoma. Here, we describe an innovative "the orange peel excision of gland (OPEG) technique" which overcomes these limitations with excellent cosmetic results. A total of 38 breasts were operated in 20 patients (18 bilateral and 2 unilateral). All the patients underwent suction-assisted liposuction and glandular excision under general anesthesia by our OPEG technique. The average operative time per breast was 60 minutes. One patient had a small hematoma which did not require evacuation. The patient satisfaction rate was 95%. The technique has reduced operative time and avoids residual gland and hematoma with excellent aesthetic outcome.

  17. A Novel Surgical Technique for Ahmed Valves in Refractory Glaucoma With Silicone Oil Endotamponade.

    Science.gov (United States)

    Davo-Cabrera, Juan Maria; Lanzagorta-Aresti, Aitor; Alcocer Yuste, Pablo

    2017-10-01

    The purpose of the study is to describe a novel technique to implant Ahmed valves in patients with refractory glaucoma because of silicone oil (SO) endotamponade PATIENTS:: Three patients with glaucoma without SO removal were used as an example for this technique. Technique report. We introduce a standard technique modification for Ahmed valves in patients with SO. This modification consists on locating the Ahmed valve more tangential to the limbus curvature instead of the usual perpendicular position and inserting the tube in the posterior chamber. The tube can be longer and run parallel to pupil. This technique allows use superotemporal quadrant (fewer complications), avoid corneal touch and decrease SO loss through the tube to subconjunctival space.

  18. Treatment of complex internal carotid artery aneurysms using radial artery grafts. Surgical technique, perioperative complications, and results in 17 patients

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Kamiyama, Hiroyasu

    2007-01-01

    Complex giant or large internal carotid artery aneurysms present a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict the occurrence of ischemic complications after internal carotid artery ligation. The present study concerns surgical technique, complications, and clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2005, we performed radial artery grafting followed immediately by parent artery occlusion in 17 patients with giant or large complex intracranial carotid aneurysms (3 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative digital subtraction angiography to assess graft patency and aneurysm obliteration. All 17 aneurysms were excluded from the cerebral circulation, with all radial artery grafts patent. Among 4 patients with cranial nerve disturbances, dysfunction was temporary in 5; in the others, oculomotor nerve paresis persisted. No perioperative cerebral infarction occurred. Sensory aphasia reflecting cerebral contusions caused by temporal lobe retraction resolved within 2 months, as did hemiparesis from a postoperative epidural hematoma. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Graft patency and aneurysm thrombosis were achieved in all patients. Cranial nerve dysfunction (III, VI) caused by altered blood flow from the internal carotid artery after occlusion was the most common complication and typically was temporary. In our experience with these difficult aneurysms, not only clipping but also reconstruction of the internal carotid artery was required, especially for wide-necked symptomatic

  19. A critical analysis of penile enhancement procedures for patients with normal penile size: surgical techniques, success, and complications.

    Science.gov (United States)

    Vardi, Yoram; Har-Shai, Yaron; Harshai, Yaron; Gil, Tamir; Gruenwald, Ilan

    2008-11-01

    Most men who request surgical penile enhancement have a normal-sized and fully functional penis but visualize their penises as small (psychological dysmorphism). The aim of this review is to describe the various reported techniques and to provide the available scientific data on the success and complication rates of penile enhancement procedures. We performed an extensive systematic review based on a search of the MEDLINE database for articles published between 1965 and 2008. The following key words were used: penis, enhancement, enlargement, phalloplasty, reconstruction, girth, lengthening, and augmentation. Only English-language articles that were related to penile surgery and dysmorphobia were sought. We excluded articles in which fewer than five cases were described and articles in which the type of surgical treatment and the outcome were not clear. Of the 176 papers found, 34 were selected and critically analyzed. We found only a small number of well-designed and comprehensive studies, and most of the published articles reported data that were obtained from small cohorts of patients. The more recently published studies presented better methodologies and descriptions of the surgical techniques than did the older publications. In general, penile enhancement surgery can cause a 1-2-cm increase in penile length and a 2.5-cm augmentation of penile girth. Unwanted outcomes and complications, namely penile deformity, paradoxical penile shortening, disagreeable scarring, granuloma formation, migration of injected material, and sexual dysfunction were reported frequently in these studies. Disappointing short- and long-term patient satisfaction rates following these procedures were also reported in most studies. To date, the use of cosmetic surgery to enlarge the penis remains highly controversial. There is a lack of any standardization of all described procedures. Indications and outcome measures are poorly defined, and the reported complications are unacceptably high

  20. Recurrent Tricuspid Insufficiency: Is the Surgical Repair Technique a Risk Factor?

    OpenAIRE

    Kara, Ibrahim; Koksal, Cengiz; Cakalagaoglu, Canturk; Sahin, Muslum; Yanartas, Mehmet; Ay, Yasin; Demir, Serdar

    2013-01-01

    This study compares the medium-term results of De Vega, modified De Vega, and ring annuloplasty techniques for the correction of tricuspid insufficiency and investigates the risk factors for recurrent grades 3 and 4 tricuspid insufficiency after repair.

  1. A surgical technique for lengthening tight hamstring muscles in patients with low back pain.

    Science.gov (United States)

    Anglès, F G; Manubens, X B; Anglès, F C

    1997-01-01

    An original technique for lengthening primary tight semitendinosus and semimembranosus muscles in their proximal portion is presented. The authors consider that primary shortening of these muscles rebounds on hip biomechanics and on the spine kinematics chain.

  2. Supraretinacular endoscopic carpal tunnel release: surgical technique with prospective case series.

    Science.gov (United States)

    Ecker, J; Perera, N; Ebert, J

    2015-02-01

    Current techniques for endoscopic carpal tunnel release use an infraretinacular approach, inserting the endoscope deep to the flexor retinaculum. We present a supraretinacular endoscopic carpal tunnel release technique in which a dissecting endoscope is inserted superficial to the flexor retinaculum, which improves vision and the ability to dissect and manipulate the median nerve and tendons during surgery. The motor branch of the median nerve and connections between the median and ulnar nerve can be identified and dissected. Because the endoscope is inserted superficial to the flexor retinaculum, the median nerve is not compressed before division of the retinaculum and, as a result, we have observed no cases of the transient median nerve deficits that have been reported using infraretinacular endoscopic techniques. © The Author(s) 2014.

  3. Surgical techniques for the treatment of carpal ligament injury in the athlete.

    Science.gov (United States)

    Paci, Gabrielle M; Yao, Jeffrey

    2015-01-01

    Treatment of intercarpal ligament injuries in the athlete requires special attention due to several practical and biomechanical considerations. Optimally, the athlete will maintain as much function and range of motion as possible with return to high-impact and load-bearing activity in a timely fashion. Several cutting-edge techniques have arisen in treatment. This article discusses injury patterns in the athlete with scapholunate injury, lunotriquetral injury, scaphotrapezial-trapezoidal injury, and extrinsic ligamentous injury, and the various approaches to addressing these injuries, with a review of the classic as well as newer, innovative techniques. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Two Techniques of Intestinal Wall Suture in Surgical Treatment of Ileus in Dogs and the Importance of Omentalisation

    Directory of Open Access Journals (Sweden)

    M. Crha

    2008-01-01

    Full Text Available Model experimental studies focused on the intestinal suture techniques in relation to healing, postoperative narrowing of the intestinal lumen or adhesion formation can not comprise a number of clinical factors (foreign body presence in the intestine, haematological abnormalities, septic peritonitis, different age of patients, etc. that under clinical practice conditions may have an effect on the healing of the intestinal suture. The aim of this clinical study was to confirm in a group of dogs surgically treated for small bowel obstruction, whether different techniques of its wall suture may affect the frequency of possible dehiscence occurrence. This study compares two different techniques of intestinal wall suture in relation to postoperative dehiscence of the intestinal wall closure. Based on the clinical observation with regard to the risk of postoperative dehiscence and possible complications in form of adhesions, also the importance of omentalisation in the suture of small bowel was evaluated. No significant difference was demonstrated (p > 0.05 in the frequency of postoperative dehiscence at the site of the intestinal wall closure between the two-layer inverting and singlelayer appositional techniques of suture. Likewise, no significant difference was demonstrated (p > 0.05 in the frequency of dehiscence of intestinal wall suture between patients that underwent intestinal suture omentalisation and those whose intestinal wall suture was not complemented with omentalisation. Based on the results of this clinical study it may be stated that both manual single-layer approximation technique and two-layer inverting technique of the intestinal wall suture are equally safe from the viewpoint of possible dehiscence, and it depends on the surgeon's preference, which one of the said techniques he or she chooses. Concurrently it may be assumed that an exactly performed suture of the intestinal wall does not necessarily require omentalisation.

  5. [A new technique for ensuring negative surgical margins during partial nephrectomy: the ex vivo ultrasound control].

    Science.gov (United States)

    Desmonts, A; Tillou, X; Le Gal, S; Secco, M; Orczyk, C; Bensadoun, H; Doerfler, A

    2013-10-01

    To evaluate the feasibility and the efficiency of intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy by urologist. Patients undergoing partial nephrectomy from July 2010 to November 2012 for T1-T2 renal tumors were included in analysis. Tumor margin status was immediately determined by ex vivo ultrasound done by the surgeon himself. Results were compared with margin status on definitive pathological evaluation. A total of 26 men and 15 women with a median age of 61 (30-82) years old were included in analysis. Intraoperative ex vivo ultrasound revealed negative surgical margins in 38 cases and positive margins in two. Final pathological results revealed negative margins in all except one case. Ultrasound sensitivity and specificity were 100% and 97%, respectively. Mean ultrasound duration was 1minute±1. Mean tumor and margin sizes were 3.4±1.8cm and 2.38±1.76mm, respectively. Intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy by a urologist seemed to be feasible, efficient and easy. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. [Pay attention to the standardized application of new techniques in surgical treatment of thyroid disease].

    Science.gov (United States)

    Tian, W; Xi, H Q; Wang, B

    2017-08-01

    The continuous development and application of new technology in thyroid surgery has promoted the rapid improvement of thyroid surgery. New technology in the field of thyroid surgery has developed rapidly. The application of neural monitoring technology has enabled the thyroid surgery to enter an accurate era. Imtraoperative neuromonitoring and continuous intraoperative neuromonitoring have made the recurrent laryngeal nerve protection more secure. Nano-carbon parathyroid gland negative imaging technology could identify parathyroid gland more precise. However, when the nano-carbon was used, the injection time, position and dosage should be grasped so as to achieve the best effect of negative imaging. Endoscopic and robotic thyroid surgery could meet the demand of cosmetic. "Treatment first, beauty second" is still the principle to be strictly followed. Do not blindly expand indications and pursue endoscopic surgery. Energy surgical instruments' update made the operation more efficient, while the instruments have some disadvantages. Thyroid surgeon must correctly understand the working principle of new energy devices and use them rationally. Through grasping the working principle and application skills of new technology in clinical work, definiting its advantages and disadvantages, adhereing to the "reasonable choice, standard application" principle, learning the pioneers' experience, the application of new thyroid diagnosis and treatment technology could be more reasonable and safe.

  7. Numerical Methods Are Feasible for Assessing Surgical Techniques: Application to Astigmatic Keratotomy

    Energy Technology Data Exchange (ETDEWEB)

    Ariza-Gracia, M.A.; Ortilles, A.; Cristobal, J.A.; Rodriguez, J.F.; Calvo, B.

    2016-07-01

    The present study proposes an experimental-numerical protocol whose novelty relies on using both the inflation and the indentation experiments simultaneously to obtain a set of material parameters which accounts for both deformation modes of the cornea: the physiological (biaxial tension) and the non-physiological (bending). The experimental protocol characterizes the corneal geometry and the mechanical response of the cornea when subjected to the experimental tests using an animal model (New Zealand rabbit's cornea). The numerical protocol reproduces the experimental tests by means of an inverse finite element methodology to obtain the set of material properties that minimizes both mechanical responses at the same time. To validate the methodology, an Astigmatic Keratotomy refractive surgery is performed on 4 New Zealand rabbit corneas. The pre and post-surgical topographies of the anterior corneal surface were measured using a MODI topographer (CSO, Italy) to control the total change in astigmatism. Afterwards, the surgery is numerically reproduced to predict the overall change of the cornea. Results showed an acceptable numerical prediction, close to the average experimental correction, validating the material parameters obtained with the proposed protocol. (Author)

  8. Adynamic Graciloplasty With a Pedicled Gracilis Muscle Flap Wrapped Around Bulbar Urethra for Treatment of Male Acquired Urinary Incontinence.

    Science.gov (United States)

    Guo, Hailin; Sa, Yinglong; Xu, Yuemin; Wang, Lin; Fei, Xiaofang

    2016-05-01

    To evaluate the efficacy of adynamic gracilis urethral myoplasty with a pedicled gracilis muscle flap wrapped around bulbar urethra for treatment of male acquired urinary incontinence. Twenty-four patients with acquired urinary incontinence (8 after radical prostatectomy, 7 after transurethral resection of the prostate, and 9 after posterior urethroplasty) were included in our study. Eighteen of these patients (75.0%) had mild to moderate urinary incontinence, and 6 (25.0%) had severe urinary incontinence. All patients received adynamic gracilis urethral myoplasty with a pedicled gracilis muscle flap wrapped around bulbar urethra and had a close follow-up. The mean postoperative maximum urethral pressure after the gracilis muscle wrapped around bulbar urethra was significantly higher than that of the preoperative measurements (P urethra can raise the urethral pressure. Adynamic graciloplasty with a pedicled gracilis muscle flap wrapped around bulbar urethra is a safe and effective surgical option in the treatment of male patients with mild to moderate incontinence, but is not suitable for severe incontinence. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Journal of Surgical Technique and Case Report - Vol 5, No 1 (2013)

    African Journals Online (AJOL)

    A Simple Technique for Adjustment of the Femoral Offset at the Site of Hip Spacer Implantation · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. K Anagnostakos, O Lorbach, P Orth, K Koch, 18-20. http://dx.doi.org/10.4103/2006-8808.118605 ...

  10. Surgical Management of Large Periorbital Cutaneous Defects: Aesthetic Considerations and Technique Refinements.

    Science.gov (United States)

    Zou, Yun; Hu, Li; Tremp, Mathias; Jin, Yunbo; Chen, Hui; Ma, Gang; Lin, Xiaoxi

    2018-02-23

    The aim of this study was to repair large periorbital cutaneous defects by an innovative technique called PEPSI (periorbital elevation and positioning with secret incisions) technique with functional and aesthetic outcomes. In this retrospective study, unilateral periorbital cutaneous defects in 15 patients were repaired by the PEPSI technique. The ages of patients ranged from 3 to 46 years (average, 19 years). The outcome evaluations included scars (Vancouver Scar Scale and visual analog scale score), function and aesthetic appearance of eyelids, and patient satisfaction. The repair size was measured by the maximum advancement distance of skin flap during operation. All patients achieved an effective repair with a mean follow-up of 18.3 months. Except one with a small (approximately 0.3 cm) necrosis, all patients healed with no complication. The mean Vancouver Scar Scale and visual analog scale scores were 2.1 ± 1.7 and 8.5 ± 1.2, respectively. Ideal cosmetic and functional outcomes were achieved in 14 patients (93.3%). All patients achieved complete satisfaction except 1 patient with partial satisfaction. The mean maximum advancement distance of skin flap was 20.2 mm (range, 8-50 mm). This study demonstrated that the PEPSI technique is an effective method to repair large periorbital cutaneous defects with acceptable functional and aesthetic outcomes.

  11. Biological limits of the undersized surgical technique: a study in goats

    NARCIS (Netherlands)

    Tabassum, A.; Meijer, G.J.; Walboomers, X.F.; Jansen, J.A.

    2011-01-01

    OBJECTIVE: The purpose of the present study was to investigate the influence of different implant placement techniques on the early bone healing response in an animal model. MATERIAL AND METHODS: In the present study, 24 cylindrical-screw-type implants with a diameter of 4.2 mm (Dyna(R)) were

  12. Comparative evaluation of gingival depigmentation by tetrafluroethane cryosurgery and surgical scalpel technique. A randomized clinical study

    Directory of Open Access Journals (Sweden)

    Suraj D Narayankar

    2017-01-01

    Full Text Available Introduction: Importance of good smile cannot be underestimated in enhancement of beauty, self-confidence and personality of a person. Health and appearance of gingiva is an essential part of attractive smile. Gingival pigmentation gives rise to unesthetic smile line. In present world, with increasing awareness to esthetic, people have become highly concerned about black gums. Various treatment modalities like abrasion, scrapping, scalpel technique, cryosurgery, electrosurgery and laser are available for treatment of gingival pigmentation. The present study was conducted with an objective of comparing efficacy of gingival depigmentation by cryosurgery and scalpel technique. Method: A Randomized control split mouth study was conducted for 25 patients with gingival pigmentation. Gingival pigmentation Index (GPI for pigmentation and Visual Analoug Scale (VAS for pain was evaluated for both test (Cryosurgery and control sites (Scalpel technique at baseline, 1month, 3months and 6 months. Results: GPI score was 3 and 2 for 21/25 and 4/25 control sites and was 22/25 and 3/25 test sites respectively at baseline. Both the groups showed significant reduction in GPI score i.e., 0 at 1 and 3 months interval after treatment. GPI score increased to 1 for 5/25 sites treated with scalpel technique and 2/25 sites treated with cryosurgery at 6 months interval (P=0.0691. This indicates recurrence rate for pigmentation is higher after scalpel treatment. VAS Score was 3 for 10/25 sites treated with scalpel and was 2 for 12/25 sites treated with cryosurgery (P<0.001. Conclusion: It can be concluded that cryosurgery can be effectively and efficiently used for depigmentation by keeping patients acceptance and comfort in mind and also the long term results and ease of use when compared to scalpel technique.

  13. A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery.

    Science.gov (United States)

    Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi

    2016-03-01

    The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.

  14. Tratamento cirúrgico da escoliose idiopática do adolescente utilizando parafusos pediculares: análise dos resultados clínicos e radiográficos Tratamiento quirúrgico de la escoliosis idiopática del adolescente utilizando tornillos pediculares: análisis de los resultados clínicos y radiográficos Surgical treatment of adolescent idiopathic scoliosis using pedicle screws: analysis of clinical and radiographic results

    Directory of Open Access Journals (Sweden)

    Alberto Ofenhejm Gotfryd

    2011-01-01

    results with SRS-24 scores. METHODS: Twenty five patients with AIS submitted to posterior arthrodesis were evaluated. The follow-up was 23.7 months ranging from 12 to 35. Radiographic criteria were reviewed regarding the deformity correction and a specific questionnaire developed by Scoliosis Research Society (SRS-24 was applied. RESULTS: The sample was composed by 92% females and 8% males. The average age was 14.2 years. The Cobb angle average measured by anterior-posterior roentnogegram was 24.4° at proximal thoracic curve, 54.9° at principal thoracic and 38.5° at the lumbar curve. The mean angular values obtained after the surgery were 11.0°; 16.7° and 12.2° respectively and the average correction of the principal thoracic curve was 69.9%. The mean SRS-24 scores were 98.1 points. Two patients had post-operative complications; however, there were no neurological complications. CONCLUSIONS: The technique showed to be effective on surgical treatment of AIS, with high percentage of deformity correction, low risk of complications and satisfactory clinical results. There was no correlation between the percentage of correction (thoracic or lumbar and/or the post-operative value of angular deformity and the SRS-24 results, neither with "satisfaction" or "self-image after surgery" domains.

  15. Total pancreatectomy and islet autotransplantation in children for chronic pancreatitis: indication, surgical techniques, postoperative management, and long-term outcomes.

    Science.gov (United States)

    Chinnakotla, Srinath; Bellin, Melena D; Schwarzenberg, Sarah J; Radosevich, David M; Cook, Marie; Dunn, Ty B; Beilman, Gregory J; Freeman, Martin L; Balamurugan, A N; Wilhelm, Josh; Bland, Barbara; Jimenez-Vega, Jose M; Hering, Bernhard J; Vickers, Selwyn M; Pruett, Timothy L; Sutherland, David E R

    2014-07-01

    Describe the surgical technique, complications, and long-term outcomes of total pancreatectomy and islet autotransplantation (TP-IAT) in a large series of pediatric patients. Surgical management of childhood pancreatitis is not clear; partial resection or drainage procedures often provide transient pain relief, but long-term recurrence is common due to the diffuse involvement of the pancreas. Total pancreatectomy (TP) removes the source of the pain, whereas islet autotransplantation (IAT) potentially can prevent or minimize TP-related diabetes. Retrospective review of 75 children undergoing TP-IAT for chronic pancreatitis who had failed medical, endoscopic, or surgical treatment between 1989 and 2012. Pancreatitis pain and the severity of pain statistically improved in 90% of patients after TP-IAT (P Puestow procedure (P = 0.018), lower body surface area (P = 0.048), higher islet equivalents (IEQ) per kilogram body weight (P = 0.001), and total IEQ (100,000) (P = 0.004) were associated with insulin independence. By multivariate analysis, 3 factors were associated with insulin independence after TP-IAT: (1) male sex, (2) lower body surface area, and (3) higher total IEQ per kilogram body weight. Total IEQ (100,000) was the single factor most strongly associated with insulin independence (odds ratio = 2.62; P < 0.001). Total pancreatectomy and islet autotransplantation provides sustained pain relief and improved quality of life. The β-cell function is dependent on islet yield. Total pancreatectomy and islet autotransplantation is an effective therapy for children with painful pancreatitis that failed medical and/or endoscopic management.

  16. Esthetic judgments of palatally displaced canines 3 months postdebond after surgical exposure with either a closed or an open technique.

    Science.gov (United States)

    Parkin, Nicola A; Freeman, Jennifer V; Deery, Chris; Benson, Philip E

    2015-02-01

    The aim of this study was to compare the esthetic judgments of orthodontists and laypeople regarding the appearance of palatally displaced canines 3 months after treatment with either a closed or an open surgical exposure and orthodontic alignment. A multicenter randomized controlled trial was undertaken in 3 hospitals in the United Kingdom. Patients with unilateral palatally displaced canines were randomly allocated to receive either a closed or an open surgical exposure. The teeth were aligned with fixed appliances, and 3 months after debond, intraoral photographs were taken. The photographs were projected in random order to 2 panels of judges (orthodontists and laypeople), who completed a questionnaire. The images of 67 participants (closed, 33; open, 34) were included. The laypeople were able to identify the operated tooth only 49.7% of the time (95% CI, 45.3%-54.0%); this was no better than chance (P = 0.880). The orthodontists were more successful but still identified the treated canine with certainty only 60.7% of the time (95% CI, 53.7%-67.8%; P = 0.003). Both panels more frequently assessed the unoperated canine to have a better appearance than the contralateral operated canine; however, there were no differences between the closed and open groups (proportion preferring unoperated canine-laypeople: closed, 58.7%; open, 57.0%; P = 0.43; and orthodontists: closed, 60.9%; open, 60.6%; P = 0.27). There is an esthetic impact to aligning a palatally displaced canine, but it is mostly minor and unlikely to be detectable by laypeople. The esthetic impact was the same, whether the canine was exposed with a closed or an open surgical technique. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  17. Acetabular osteotomy for double boarding in lateral decubitus. Anatomical bases and surgical technique

    International Nuclear Information System (INIS)

    Lazennec, J Y; Del Vecchio, R; Saillant, G

    2001-01-01

    The periacetabular osteotomies of reorientation of the eotilo have a reputation of being difficult from the technical point of view. The authors present a technique of juxta acetabular osteotomy that respects the posterior column of the acetabulo the same as the GANZ technique. The osteotomy is of simpler realization thanks to an installation that allows carrying out two simultaneous boarding. The osteotomy lines, their rectilinear and controllable in permanency through of images intensificator and they don't constitute any risk for the essential vascular contribution of the obturatriz artery and their branches. Their other interest comes represented by the possibility of correcting easily the parasitic retroversion associated to the descent of the whole eotilo, that it allows to avoid the bad positions that they affect the center of the articulation and the widths acetabular

  18. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model

    Directory of Open Access Journals (Sweden)

    Hughes Matthew

    2018-01-01

    Discussion: For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction.

  19. Surgical technique for permanent intracoelomic radiotransmitter placement in Anegada iguanas (Cyclura pinguis).

    Science.gov (United States)

    Ferrell, Shannon T; Marlar, Annajane B; Alberts, Allison C; Young, Lee A; Bradley, Kelly; Hurlbut, Sandra L; Lung, Nancy P

    2005-12-01

    Twenty-four juvenile to subadult Anegada iguanas (Cyclura pinguis), captive-reared in a propagation facility, were designated by a coordinated recovery program for release in the summer of 2003. To facilitate postrelease monitoring, a radiotransmitter device was placed within the coelomic cavity of each animal under general anesthesia before release. The equipment sterilization technique and the method of attachment of the transmitters to the coelomic body wall resulted in functional transmitters and acceptably low rates of mortality associated with the procedure.

  20. Shoulder arthroplasty in osteoarthritis: current concepts in biomechanics and surgical technique

    Science.gov (United States)

    Merolla, G; Nastrucci, G; Porcellini, G

    Shoulder arthroplasty is a technically demanding procedure to restore shoulder function in patients with severe osteoarthritis of the glenohumeral joint. The modern prosthetic system exploit the benefits of modularity and the availibility of additional sizes of the prosthetic components. In this paper we describe the biomechanics of shoulder arthroplasty and the technique for shoulder replacement including total shoulder arthroplasty (TSA) with all-polyethylene and metal-backed glenoid component, humeral head resurfacing and stemless humeral replacement. PMID:24251240

  1. Unstable elbow dislocations: the description and cadaveric feasibility study of a new surgical technique

    Directory of Open Access Journals (Sweden)

    Harris Mark

    2015-01-01

    Full Text Available Introduction: A small proportion of simple elbow dislocations are grossly unstable and joint congruence is not maintained after reduction. In this rare situation operative treatment is indicated. We describe a new intra articular reconstruction that utilises a slip of triceps tendon to provide immediate stability to the elbow. Methods: We assessed 20 cadaveric elbows, measuring the length of triceps tendon available and required to complete the reconstruction. We then sequentially sectioned the ligamentous stabilisers of an elbow before performing the new technique. We measured the displacement and angulation possible at the elbow before and after the reconstruction. Results: All 20 elbows had sufficient triceps tendon length to complete the new technique. Prior to the reconstruction greater than 30 mm of joint distraction and 90 degrees varus or valgus angulation was possible. Following the reconstruction it was not possible to re-dislocate the elbow. Only 2 mm of joint distraction and 10 degrees of varus or valgus angulation were possible with the triceps graft fixed in position. Discussion: This novel technique elegantly avoids many of the problems associated with current methods. We have demonstrated that it is technically feasible and easy to perform with minimal equipment requirements or costs.

  2. Limbal Stem Cell-Sparing Corneoscleroplasty with Peripheral Intralamellar Tuck: A New Surgical Technique for Keratoglobus

    Directory of Open Access Journals (Sweden)

    Elias Jarade

    2017-04-01

    Full Text Available Purpose: To describe the technique of limbal stem cell-sparing corneoscleroplasty for the management of advanced keratoglobus. Methods: A patient with bilateral advanced keratoglobus, with best-corrected visual acuity of 20/400 in the right eye and 20/200 in the left eye, underwent limbal stem cell-sparing corneoscleroplasty of the right eye. Initially, a 360-degree limbal incision with 200-μm depth was created, followed by a sublimbal tunnel dissection into the sclera, in order to conserve stem cells. Next, a limbus-to-limbus lamellar keratectomy at 200-μm depth was performed. Meanwhile, a donor corneoscleral button with preserved endothelium of the central 8 mm was fashioned. Prior to suturing the donor corneoscleral graft using a modified suturing technique to cover its scleral component, a full-thickness trephination of 8-mm diameter was completed in the central host cornea. Results: Reepithelialization occurred within the first week. No episodes of rejection, intraocular pressure spikes, or epithelial breakdown were observed postoperatively. At the 6-month follow-up, the patient had 20/70 best-corrected vision and a smooth cornea with regular astigmatism on topography. Conclusion: Limbal stem cell-sparing corneoscleroplasty is a single-step technique for restoring the structural integrity of the cornea in advanced keratoglobus while preserving the host limbal stem cells.

  3. The Demographics of Patients with Skin Cancer who Underwent Surgery in Diyarbakır and Performed Surgical Techniques

    Directory of Open Access Journals (Sweden)

    Burhan Özalp

    2018-06-01

    Full Text Available Objective: The major factor for developing malignant skin cancers is sunlight exposure. This study aimed to evaluate the demographics of patients with skin cancers who underwent surgery in Diyarbakır where the population is exposed to more sunlight than most other Turkish cities. Methods: The medical records of patients who underwent surgery for malignant skin cancer excision between 2011 and 2016 were searched using University Hospital’s patient database program. Data about patients’ demographics, cancer features, and the surgical techniques performed were collected. Results: Over a 5-year period, 190 patients underwent surgical excision. The male to female ratio was 1.56, and the mean age was 65.8 ± 15.7 (range, 20-94 years. The most common skin cancer was basal cell carcinoma (n=138, 72.7%, followed by squamous cell carcinoma (n=45, 23.7% and malignant melanoma (n=5, 2.6%. The most common surgery was primary excision, which was performed in 90 of 190 patients (47.36%; tissue reconstruction with a skin graft or flap surgery was required for the remaining 100 (52.63%, showing a significant difference (p<0.001. Conclusion: Basal cell carcinoma is the most common skin cancer, and less than half of the patients sought treatment immediately after they recognized the lesion. The public should be educated about skin cancers to increase early diagnosis and encourage timely treatment, thereby decreasing morbidity and mortality from skin cancer.

  4. Current surgical treatment option, utilizing robot-assisted laparoscopic surgery in obese women with endometrial cancer: Farghalys technique

    International Nuclear Information System (INIS)

    Farghaly, S.A.

    2013-01-01

    Background: Endometrial cancer is the most prevalent cancer of the female genital tract in North America. Minimally invasive laparoscopic-assisted surgery and panniculectomy in obese women with endometrial cancer are associated with an improved lymph node count, and lower rate of incisional complications than laparotomy. Methods: Technique for robot-assisted laparoscopic surgery for obese women with endometrial cancer is detailed. Results: Robot-assisted laparoscopic surgical staging, pelvic and para-aortic lymphadenectomy and panniculectomy allow us to avoid the use of postoperative pelvic radiation which is recommended in women with histopathology high-risk findings: deep myometrial invasion or high grade histology. The procedure has the advantage of three-dimensional vision, ergonomic, intuitive control, and wristed instrument that approximate the motion of the human hand. Conclusion: Robot-assisted laparoscopic surgical staging, and panniculectomy in these patients are a safe, and effective alternative to laparoscopic, and laparotomy surgery. It is an ideal tool for performing the complex oncologic procedures encountered in endometrial cancer staging that requires delicate retroperitoneal, pelvic and para-aortic lymph node dissection, while maintaining the principles of oncologic surgery but in a minimally invasive fashion.

  5. Correlation between histological outcome and surgical cartilage repair technique in the knee: A meta-analysis.

    Science.gov (United States)

    DiBartola, Alex C; Everhart, Joshua S; Magnussen, Robert A; Carey, James L; Brophy, Robert H; Schmitt, Laura C; Flanigan, David C

    2016-06-01

    Compare histological outcomes after microfracture (MF), autologous chondrocyte implantation (ACI), and osteochondral autograft transfer (OATS). Literature review using PubMed MEDLINE, SCOPUS, Cumulative Index for Nursing and Allied Health Literature (CINAHL), and Cochrane Collaboration Library. Inclusion criteria limited to English language studies International Cartilage Repair Society (ICRS) grading criteria for cartilage analysis after ACI (autologous chondrocyte implantation), MF (microfracture), or OATS (osteochondral autografting) repair techniques. Thirty-three studies investigating 1511 patients were identified. Thirty evaluated ACI or one of its subtypes, six evaluated MF, and seven evaluated OATS. There was no evidence of publication bias (Begg's p=0.48). No statistically significant correlation was found between percent change in clinical outcome and percent biopsies showing ICRS Excellent scores (R(2)=0.05, p=0.38). Percent change in clinical outcome and percent of biopsies showing only hyaline cartilage were significantly associated (R(2)=0.24, p=0.024). Mean lesion size and histological outcome were not correlated based either on percent ICRS Excellent (R(2)=0.03, p=0.50) or percent hyaline cartilage only (R(2)=0.01, p=0.67). Most common lesion location and histological outcome were not correlated based either on percent ICRS Excellent (R(2)=0.03, p=0.50) or percent hyaline cartilage only (R(2)=0.01, p=0.67). Microfracture has poorer histologic outcomes than other cartilage repair techniques. OATS repairs primarily are comprised of hyaline cartilage, followed closely by cell-based techniques, but no significant difference was found cartilage quality using ICRS grading criteria among OATS, ACI-C, MACI, and ACI-P. IV, meta-analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. [TVT and TOT for surgical correction of female stress urinary incontinence. Comparison between techniques].

    Science.gov (United States)

    Torres Zambrano, G; Lujan Galán, M; Martín García, C; García Tello, A; Rodríguez García, N; Berenguer Sánchez, A

    2008-10-01

    Retrospective analysis of a series of patients with stress urinary incontinence that underwent surgery in our department, by means of the TVT and TOT techniques. We evaluate post operative continence, considering "cured" the patient with complete continence and "failure" any type of involuntary stress urine leak, independently of its severity registering the time of its appearance. For this purpose we used the Kaplan-Meier analysis comparing both techniques with the Breslow test. Additionally, postoperative complications were evaluated. 128 patients who underwent surgery by TVT (69 patients, 53.9%) and TOT (59 patients, 46.1%). Mean age was 54.4 years for TVT (95% CI 52.0-56.8) and 59 years for TOT (95% CI 55.9-62.1). Mean follow-up time was 18.7 months for TVT (95% CI 15.6-21.9) and 7.4 months for TOT (95% CI 5.8-8.9). Overall continence rate was 86.7%, 88.4% for TVT and 84.7% for TOT The probability of being continent six months after surgery was 89.1% for TVT and 78.2% for TOT (no significant differences, p = 0.31), with almost all failures within the first six months after surgery. TVT was more frecuently associated with urgency symptoms (33.3%, p = 0.001) and urge incontinence (18.8%,p = 0.16), urinary retention (11.6%, p = 0.38), and prevesical hematoma requiring mesh retrieval. Greater post operative pain was observed with TOT (20.3%, p = 0.005). Our results evidence a similar efficacy with both techniques, with the failures appearing over the first months after surgery. Complications of the voiding urgency type are significantly more frequent with TVT.

  7. The results of surgical treatment of oviductal infertility with use of microsurgical technique

    International Nuclear Information System (INIS)

    Cislo, M.; Murawski, M.; Palczynski, B.

    1993-01-01

    40 women were operated on infertility due to oviductal factor. This kind of infertility has been previously diagnosed by hysterosalpingography examination and then verified in 22 cases (55%) by laparoscopy combined with chromotubation. The operations were carried out with use of microsurgical technique and instruments. At the same time the prophylactics of postoperative intraperitoneal adhesions was applied. Seven pregnancies were obtained, that makes 17.5% of success. It is an outcome comparable with results presented by many other world centers of gynecological microsurgery. (author)

  8. Lateral high abdominal ovariopexy: an original surgical technique for protection of the ovaries during curative radiotherapy for Hodgkin's disease

    International Nuclear Information System (INIS)

    Gaetini, A.; De Simone, M.; Urgesi, A.; Levis, A.; Resegotti, A.; Ragona, R.; Anglesio, S.

    1988-01-01

    An original surgical method for gonadal protection in young women given pelvic radiation for Hodgkin's disease is presented. Lateral high ovarian transposition (LHAO) consists of the transposition of the ovaries into the paracolic gutter during staging laparotomy, after disconnecting the gonads from the fallopian tubes by dividing the tubo-ovarian vessels. The technique's effectiveness was assessed by a study using clinical investigation, radioimmunoassay (RIA) determination of sex hormones, and dosimetry; of 18 patients treated, 10 participated in the study. All but one have normal menses and hormone values, and one pregnancy occurred. We also calculated the doses absorbed by the ovaries and proved that, during inverted Y irradiation following LHAO, the ovaries are exposed to nearly one-half the dose they receive after traditional medial transposition. During subtotal nodal irradiation after LHAO, the irradiation dose is higher than after medialisation, but absolute values are minimal and castration is not induced

  9. Radiographic failure and rates of re-operation after acromioclavicular joint reconstruction: a comparison of surgical techniques.

    Science.gov (United States)

    Spencer, H T; Hsu, L; Sodl, J; Arianjam, A; Yian, E H

    2016-04-01

    To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries. We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis. Radiographic failure occurred in 33/154 cases (21.4%), with the lowest rate in Technique 4 (2/42 4.8%, p = 0.001). Half the failures occurred by six weeks, and the Kaplan-Meier survivorship at 24 months was 94.4% (95% confidence interval (CI) 79.6 to 98.6) for Technique 4 and 69.9% (95% CI 59.4 to 78.3) for the other techniques when combined. In multivariable survival analysis, Technique 4 had better survival than other techniques (Hazard Ratio 0.162, 95% CI 0.039 to 0.068, p = 0.013). Among 155 patients with a minimum of six months post-operative insurance coverage, re-operation occurred in 9.7% (15 patients). However, in multivariable logistic regression, Technique 4 did not reach a statistically significant lower risk for re-operation (odds ratio 0.254, 95% CI 0.05 to 1.3, p = 0.11). In this retrospective series, anatomical CC ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. Anatomical coracoclavicular ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. ©2016 The British Editorial

  10. Navigation of Pedicle Screws in the Thoracic Spine with a New Electromagnetic Navigation System: A Human Cadaver Study

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    2015-01-01

    Full Text Available Introduction. Posterior stabilization of the spine is a standard procedure in spinal surgery. In addition to the standard techniques, several new techniques have been developed. The objective of this cadaveric study was to examine the accuracy of a new electromagnetic navigation system for instrumentation of pedicle screws in the spine. Material and Method. Forty-eight pedicle screws were inserted in the thoracic spine of human cadavers using EMF navigation and instruments developed especially for electromagnetic navigation. The screw position was assessed postoperatively by a CT scan. Results. The screws were classified into 3 groups: grade 1 = ideal position; grade 2 = cortical penetration <2 mm; grade 3 = cortical penetration ≥2 mm. The initial evaluation of the system showed satisfied positioning for the thoracic spine; 37 of 48 screws (77.1%, 95% confidence interval [62.7%, 88%] were classified as group 1 or 2. Discussion. The screw placement was satisfactory. The initial results show that there is room for improvement with some changes needed. The ease of use and short setup times should be pointed out. Instrumentation is achieved without restricting the operator’s mobility during navigation. Conclusion. The results indicate a good placement technique for pedicle screws. Big advantages are the easy handling of the system.

  11. Surgical management of first branchial cleft anomaly presenting as infected retroauricular mass using a microscopic dissection technique.

    Science.gov (United States)

    Chan, Kai-Chieh; Chao, Wei-Chieh; Wu, Che-Ming

    2012-01-01

    This is a detailed description of the clinical and anatomical presentation of the first branchial cleft anomaly presenting as retroauricular infected mass. Our experience with a microscopic dissection with control of the sinus lumen from within the cyst is also described. Between 2001 and 2008, patients with the final histologic diagnosis of first branchial cleft anomaly in the retroauricular area were managed with a microscopic dissection technique with control of the sinus lumen from within the cyst. Classifications were done in accordance with Work, Olsen, and Chilla. Outcomes measured intervention as a function of disease recurrence and complications including facial nerve function was used. Eight patients with a mean age of 14.2 years were enrolled, and this included 4 females and 4 males. Four type 1 and 4 type 2 lesions as per the Work's and Chilla's classification were found, and there were 5 sinuses, 2 fistulae, and 1 cyst according to Olsen's classification. All patients presented to the department with acute infection at the time of diagnosis. Five of the 8 patients had previous surgical treatment, 2 of those had up to 3 previous operations. None of the patients were complicated by disease recurrence or had surgical related complications (facial nerve paresis or paralysis, infection, canal stenosis) requiring reoperation with more than 1 year of follow-up. First branchial cleft anomaly presenting as retroauricular infected mass can be effectively treated by adopting a microscopic dissection technique with control of the sinus lumen from within the cyst. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Surgical Techniques for Diaphragmatic Resection During Cytoreduction in Advanced or Recurrent Ovarian Carcinoma: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Bogani, Giorgio; Ditto, Antonino; Martinelli, Fabio; Lorusso, Domenica; Chiappa, Valentina; Donfrancesco, Cristina; Di Donato, Violante; Indini, Alice; Aletti, Giovanni; Raspagliesi, Francesco

    2016-02-01

    Optimal cytoreduction is one the main factors improving survival outcomes in patients affected by ovarian cancer (OC). It is estimated that approximately 40% of OC patients have gross disease located on the diaphragm. However, no mature data evaluating outcomes of surgical techniques for the management of diaphragmatic carcinosis exist. In the present study, we aimed to estimate surgery-related morbidity of different surgical techniques for diaphragmatic cytoreduction in advanced or recurrent OC. PubMed (MEDLINE), Web of Science, and Clincaltrials.gov databases were searched for records estimating outcomes of diaphragmatic peritoneal stripping (DPS) or diaphragmatic full-thickness resection (DFTR) for OC. The meta-analysis was performed using the Cochrane Review software. For the final analysis, 5 articles were available, including 272 patients. Diaphragmatic peritoneal stripping and DFTR were performed in 197 patients (72%) and 75 patients (28%), respectively. Pooled analysis suggested that the estimated pleural effusion rate was 43% and 51% after DPS and DFTR, respectively. The need for pleural punctures or chest tube placement was 4% and 9% after DPS and DFTR, respectively. The rate of postoperative pneumothorax (4% vs 9%; odds ratio, 0.31; 95% confidence interval, 0.05-2.08) and subdiaphragmatic abscess (3% vs 3%; odds ratio, 0.45; 95% confidence interval, 0.09-2.31) were similar after the execution of DPS and DFTR. Diaphragmatic surgery is a crucial step during cytoreduction for advanced or recurrent OC. Obviously, the choice to perform DPS or DFTR depends on the infiltration of the diaphragmatic muscle or not. Both the procedures are associated with a low pulmonary complication and chest tube placement rates.

  13. Creation of false pedicles and a neo-pelvis for lumbopelvic reconstruction following en bloc resection of an iliosacral chondrosarcoma with lumbar spine extension: technical note.

    Science.gov (United States)

    Mendel, Ehud; Nathoo, Narendra; Scharschmidt, Thomas; Schmidt, Carl; Boehmler, James; Mayerson, Joel L

    2014-03-01

    En bloc resection with negative tumor margins remains the principal treatment option for control or cure of primary pelvic chondrosarcomas, as current adjuvant therapies remain ineffective. Iliosacral chondrosarcomas with involvement of the sciatic notch are sufficiently challenging tumors. However, when there is concomitant lumbar extension requiring resection of the pedicles to maintain negative surgical margins, transpedicular screw fixation is not possible, making reconstruction of the lumbopelvic junction extremely challenging. A patient with an iliosacral chondrosarcoma with lumbar spine extension is presented in this report to illustrate a novel lumbopelvic spinal construct. Following combined external pelvectomy and hemisacrectomy with contralateral L3-5 hemilaminectomy and ipsilateral pediculotomy, bicortical transvertebral body screws were substituted for the missing pedicles, resulting in the creation of "false pedicles," which were further supplemented with an autologous vascularized fibular strut graft from the amputated lower limb and applied to the lateral aspect of the vertebral bodies. The creation of false pedicles allowed for a robust reconstruction of the lumbopelvic junction, including maintaining pelvic ring integrity with a "neo-pelvis", creating a functional load-bearing construct adequate for early mobilization and ambulation. The biomechanical dynamics of this unique construct are also discussed.

  14. Substitution of the anterior cruciate ligament: a long-term histologic and biomechanical study with autogenous pedicled grafts of the iliotibial band in dogs

    NARCIS (Netherlands)

    Rens, van T.J.G.; Berg, van den A.F.; Huiskes, H.W.J.; Kuypers, W.

    1986-01-01

    This paper reports the experience with anterior cruciate ligament (ACL) substitution by standardized pedicled strips of the iliotibial band, fixed to the tibia and femur with a bone-peg fixation technique. Thirty-two young adult (± one year old) Labrador dogs were used for the experiments (58

  15. A Randomized Controlled Trial of Video Education versus Skill Demonstration: Which Is More Effective in Teaching Sterile Surgical Technique?

    Science.gov (United States)

    Pilieci, Stephanie N; Salim, Saad Y; Heffernan, Daithi S; Itani, Kamal M F; Khadaroo, Rachel G

    2018-04-01

    Video education has many advantages over traditional education including efficiency, convenience, and individualized learning. Learning sterile surgical technique (SST) is imperative for medical students, because proper technique helps prevent surgical site infections (SSIs). We hypothesize that video education is at least as effective as traditional skill demonstration in teaching first-year medical students SST. A video series was created to demonstrate SST ( https://www.youtube.com/playlist?list=PLcRU-gvOmxE2mwMWkowouBkxGXkLZ8Uis ). A randomized controlled trial was designed to assess which education method best teaches SST: video education or skill demonstration. First-year medical students (n = 129) were consented and randomly assigned into two groups: those who attended a skill demonstration (control group; n = 70) and those who watched the video series (experimental group; n = 59). The control group attended a pre-existing 90-minute nurse educator-led skill demonstration. Participants then completed a 30-item multiple choice quiz to test their knowledge. Each group then received the alternate education method and completed a 23-item follow-up survey to determine their preferred method. Seven 2- to 6-minute videos (30 minutes total) were created on surgical attire, scrubbing, gowning and gloving, and maintaining sterility. The experimental group (n = 51) scored higher on the quiz compared with the control group (n = 63) (88% ± 1% versus 72% ± 1%; p < 0.0001). Students preferred the videos when it came to convenience, accessibility, efficiency, and review, and preferred the skill demonstration when it came to knowledge retention, preparedness, and ease of completion. Video education is superior to traditional skill demonstration in providing medical students with knowledge of SST. Students identified strengths to each method of teaching. Video education can augment medical students' knowledge prior to their operating room

  16. Fixation of revision implants is improved by new surgical technique to crack the sclerotic endosteal rim.

    Science.gov (United States)

    Kold, S; Soballe, K; Mouzin, O; Chen, Xiangmei; Toft, M; Bechtold, J

    2002-01-01

    We used an experimental model producing a tissue response with a sclerotic endosteal neo-cortical rim associated with implant loosening in humans: a 6 mm PMMA cylinder pistoned 500 m concentrically in a 7.5 mm hole, with polyethylene particles. At a second operation at eight weeks, the standard revision procedure removed the fibrous membrane in one knee, and the crack revision procedure was used to crack the sclerotic endosteal rim in the contralateral knee. Once stability was achieved following the revision procedures, loaded Ti plasma sprayed implants were inserted into the revision cavities of 8 dogs for an additional 4 weeks. Revision implant fixation (ultimate shear strength and energy absorption) was significantly enhanced by cracking the sclerotic endosteal rim. In conclusion, we demonstrated a simple technique of cracking the sclerotic endosteal rim as an additional method for improving revision fixation. (Hip International 2002; 2: 77-9).

  17. Advances in surgical techniques in non-small cell lung cancer.

    Science.gov (United States)

    Kim, Anthony W; Detterbeck, Frank C

    2013-12-01

    Thoracic surgery is a dynamic field, and many scientific, technological, technical, and organizational changes are occurring. A prominent example is the use of less invasive approaches to major resection of non-small cell lung cancer (NSCLC), both thoracoscopic and robotic. Sophisticated technology corroborated by clinical data has led to these approaches becoming accepted additions to the armamentarium. Additionally, improvements in perioperative pain management have also contributed to dramatically changing the experience of patients who undergo modern thoracic surgery. Lung cancer is being detected more often at an early stage. At the same time, advances in techniques, patient care, clinical science, and multidisciplinary treatment support an increased role for aggressive resection in the face of larger locally advanced tumors or for those with limited metastatic disease. These advances, conducted in the setting of multidisciplinary decision making, have resulted in real and palpable advancements for patients with lung cancer. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Transplantation of infant kidneys - the surgical technique en bloc and transplant position variation: A case report

    Directory of Open Access Journals (Sweden)

    Popović Vladan

    2015-01-01

    Full Text Available Introduction. Due to the ever-present lack of kidney transplant grafts, more and more organs obtained from the so-called “marginal donors” group are accepted, which can provide suboptimal effect of transplantation, depending on their characteristics and/or implantation techniques. Case report. We presented a case with successful variation of kidney position with modified approach of kidney transplantation from an infant to an adult female patient with normal postoperative recovery. Urethral anastomosis was performed without antireflux procedure and this has not led to the development of reflux disease at an early stage. Conclusion. The position of a pair of kidneys proved to be satisfactory despite the growth of the kidney to the expected size and relatively small pelvis. There were no problems with venous stasis and kidney function from the very beginning was good.

  19. Comparison of surgical techniques of 111 medial malleolar fractures classified by fracture geometry.

    Science.gov (United States)

    Ebraheim, Nabil A; Ludwig, Todd; Weston, John T; Carroll, Trevor; Liu, Jiayong

    2014-05-01

    Evaluation of operative techniques used for medial malleolar fractures by classifying fracture geometry has not been well documented. One hundred eleven patients with medial malleolar fractures (transverse n = 63, oblique n = 29, vertical n = 7, comminuted n = 12) were included in this study. Seventy-two patients had complicating comorbidities. All patients were treated with buttress plate, lag screw, tension band, or K-wire fixation. Treatment outcomes were evaluated on the basis of radiological outcome (union, malunion, delayed union, or nonunion), need for operative revision, presence of postoperative complications, and AOFAS Ankle-Hindfoot score. For transverse fractures, tension band fixation showed the highest rate of union (79%), highest average AOFAS score (86), lowest revision rate (5%), and lowest complication rate (16%). For oblique fractures, lag screws showed the highest rate of union (71%), highest average AOFAS score (80), lowest revision rate (19%), and lowest complication rate (33%) of the commonly used fixation techniques. For vertical fractures, buttress plating was used in every case but 1, achieving union (whether normal or delayed) in all cases with an average AOFAS score of 84, no revisions, and a 17% complication rate. Comminuted fractures had relatively poor outcomes regardless of fixation method. The results of this study suggest that both tension bands and lag screws result in similar rates of union for transverse fractures of the medial malleolus, but that tension band constructs are associated with less need for revision surgery and fewer complications. In addition, our data demonstrate that oblique fractures were most effectively treated with lag screws and that vertical fractures attained superior outcomes with buttress plating. Level III, retrospective comparative series.

  20. Advances in the Surgical Management of Articular Cartilage Defects: Autologous Chondrocyte Implantation Techniques in the Pipeline.

    Science.gov (United States)

    Stein, Spencer; Strauss, Eric; Bosco, Joseph

    2013-01-01

    The purpose of this review is to gain insight into the latest methods of articular cartilage implantation (ACI) and to detail where they are in the Food and Drug Administration approval and regulatory process. A PubMed search was performed using the phrase "Autologous Chondrocyte Implantation" alone and with the words second generation and third generation. Additionally, clinicaltrials.gov was searched for the names of the seven specific procedures and the parent company websites were referenced. Two-Stage Techniques: BioCart II uses a FGF2v1 culture and a fibrinogen, thrombin matrix, whereas Hyalograft-C uses a Hyaff 11 matrix. MACI uses a collagen I/III matrix. Cartipatch consists of an agarose-alginate hydrogel. Neocart uses a high-pressure bioreactor for culturing with a type I collagen matrix. ChondroCelect makes use of a gene expression analysis to predict chondrocyte proliferation and has demonstrated significant clinical improvement, but failed to show superiority to microfracture in a phase III trial. One Step Technique: CAIS is an ACI procedure where harvested cartilage is minced and implanted into a matrix for defect filling. As full thickness defects in articular cartilage continue to pose a challenge to treat, new methods of repair are being researched. Later generation ACI has been developed to address the prevalence of fibrocartilage with microfracture and the complications associated with the periosteal flap of first generation ACI such as periosteal hypertrophy. The procedures and products reviewed here represent advances in tissue engineering, scaffolds and autologous chondrocyte culturing that may hold promise in our quest to alter the natural history of symptomatic chondral disease.

  1. Real-time Continuous Esophageal High-resolution Manometry (HRM) During Laparoscopic Heller Myotomy and Dor Fundoplication for the Treatment of Achalasia. A Promising Novelty in Regards of Perfecting Surgical Technique: Could It Guide Surgical Technique Toward Excellent Results?

    Science.gov (United States)

    Triantafyllou, Tania; Doulami, Georgia; Papailiou, Joanna; Mantides, Apostolos; Zografos, Georgios; Theodorou, Dimitrios

    2016-12-01

    High-resolution manometry (HRM) is the gold-standard diagnostic tool for achalasia of the esophagus. Laparoscopic Heller-Dor technique is the preferred surgical approach with success rate estimated 90%. The use of intraoperative HRM provides real-time estimation of intraluminal esophageal pressures and identifies the exact points of esophageal luminal pressure during laparoscopy. Ten patients with achalasia underwent surgery. All patients preoperatively completed 1 manometric study and Quality of Life questionnaires (EORTC QLQ-C30 version 3.0) with Eckardt scores. We collected intraoperative manometry data and repeated manometric studies, EORTC QLQ-C30, and Eckardt scores postoperatively. Median Eckardt score was decreased from 7.5 to 0.5, mean resting pressure decreased from 51.4 to 11.9 mm Hg, whereas mean residual pressure diminished from 45.9 to 9.5 mm Hg postoperatively. The simultaneous use of HRM during the Heller-Dor technique may lead to an individualized management of the disease.

  2. Free tissue transfer versus pedicled flap reconstruction of head and neck malignancy defects.

    LENUS (Irish Health Repository)

    O'Neill, J P

    2012-02-01

    BACKGROUND: With the advent of microsurgery the pedicled flap is considered by many to be an outdated surgical option. AIMS: To explore the relationship between flap survival and pre-morbid risk factors, conduct a comparative analysis of flap and systemic morbidities and complete a cosmesis and functionality assessment for oral and oropharyngeal reconstruction patients. METHODS: 114 patients, over a 13-year period, who had a one-stage reconstructive procedure employing the pectoralis major myocutaneous flap (PMMF) or radial forearm-free flap (RFFF). RESULTS: Variables, including age, smoking and radiation exposure were not statistically significant predictors of flap survival probability. Atelectasis was a significant post-op finding of RFFF patients. Flap dehiscence of >50% was a significant morbidity of PMMF. No statistical difference in cosmetic deformity, diet and socialisation was noted. CONCLUSIONS: Pectoralis major myocutaneous flap remains an enduring and safe flap; however, the RFFF has markedly improved speech performance over the PMMF.

  3. Massive cuff tears treated with arthroscopically assisted latissimus dorsi transfer. Surgical technique

    Science.gov (United States)

    De Cupis, Vincenzo; De Cupis, Mauro

    2012-01-01

    Summary Latissimus dorsi transfer is our preferred treatment for active disabled patients with a posterosuperior massive cuff tear. We present an arthroscopically assisted technique which avoids an incision through the deltoid obtaining a better and faster clinical outcome. The patient is placed in lateral decubitus. After the arthroscopic evaluation of the lesion through a posterior and a posterolateral portal, with the limb in traction we perform the preparation of the greater tuberosity of the humerus. We place the arm in abduction and internal rotation and we proceed to the harvest of the latissimus dorsi and the tendon preparation by stitching the two sides using very resistant sutures. After restoring limb traction, under arthroscopic visualization, we pass a curved grasper through the posterolateral portal by going to the armpit in the space between the teres minor and the posterior deltoid. Once the grasper has exited the access at the level of the axilla we fix two drainage transparent tubes, each with a wire inside, and, withdrawing it back, we shuttle the two tubes in the subacromial space. After tensioning the suture wires from the anterior portals these are assembled in a knotless anchor of 5.5 mm that we place in the prepared site on the greater tuberosity of the humerus. A shoulder brace at 15° of abduction and neutral rotation protect the patient for the first month post-surgery but physical therapy can immediately start. PMID:23738290

  4. Results of a protocol of transfusion threshold and surgical technique on transfusion requirements in burn patients.

    Science.gov (United States)

    O'Mara, Michael S; Hayetian, Fernando; Slater, Harvey; Goldfarb, I William; Tolchin, Eric; Caushaj, Philip F

    2005-08-01

    Blood loss and high rates of transfusion in burn centers remains an area of ongoing concern. Blood use brings the risk of infection, adverse reaction, and immunosuppression. A protocol to reduce blood loss and blood use was implemented. Analysis included 3-year periods before and after institution of the protocol. All patients were transfused for a hemoglobin below 8.0 gm/dL. Operations per admission did not change during the two time periods (0.78 in each). Overall units transfused per operation decreased from 1.56+/-0.06 to 1.25+/-0.14 units after instituting the protocol (pburns of less than 20% surface area, declining from 386 to 46 units after protocol institution, from 0.37 to 0.04 units per admission, and from 0.79 to 0.08 units per operation in this group of smallest burns. There was no change noted in the larger burns. This study suggests that a defined protocol of hemostasis, technique, and transfusion trigger should be implemented in the process of burn excision and grafting. This will help especially those patients with the smallest burns, essentially eliminating transfusion need in that group.

  5. Reconstruction of the mandible and the maxilla: the evolution of surgical technique.

    Science.gov (United States)

    Genden, Eric M

    2010-01-01

    The upper and lower jaws play an essential role in mastication, articulation, and cosmetic form. The mandible provides support for tongue position and elevation of the larynx during swallowing, while the maxilla provides support for the nasal structures as well as an opposing structure to the mandible during mastication. The evolution of mandibular and maxillary reconstruction dates back to the early 19th century. Before the introduction of free tissue transfer, a variety of local flaps, regional flaps, and prosthetics were introduced, yet each was met with eventual failure. Since the introduction of free tissue transfer, mandibular and maxillary reconstruction has become as much of an art as it has a science. Whether the mandibular or the palatomaxillary defects are a result of trauma, congenital deformity, or tumor extirpation, the resultant effect often disrupts both form and function. With these considerations taken together, jaw reconstruction is a unique undertaking in which the artistic reconstruction of the facial skeleton is met with the science of reestablishing the mechanics of mastication. The site, size, and associated soft-tissue defects represent the 3 most important factors in determining the impact of a given defect on function and aesthetics. There is also an inherent difference between defects that are sustained in a controlled fashion, such as during cancer ablation, and those that result from trauma. The consideration of these complexities in jaw reconstruction is reflected in the wide variety of approaches and techniques that have evolved over the past century.

  6. Advantages, Disadvantages, Indications, Contraindications and Surgical Technique of Laryngeal Airway Mask.

    Science.gov (United States)

    Jannu, Anubhav; Shekar, Ashim; Balakrishna, Ramdas; Sudarshan, H; Veena, G C; Bhuvaneshwari, S

    2017-12-01

    The beauty of the laryngeal mask is that it forms an air tight seal enclosing the larynx rather than plugging the pharynx, and avoid airway obstruction in the oropharynx. The goal of its development was to create an intermediate form of airway management face mask and endotracheal tube. Indication for its use includes any procedure that would normally involve the use of a face mask. The laryngeal mask airway was designed as a new concept in airway management and has been gaining a firm position in anesthetic practice. Despite wide spread use the definitive role of the laryngeal mask airway is yet to be established. In some situations, such as after failed tracheal intubation or in oral surgery its use is controversial. There are several unresolved issues, for example the effect of the laryngeal mask on regurgitation and whether or not cricoids pressure prevents placement of mask. We review the techniques of insertion, details of misplacement, and complications associated with use of the laryngeal mask. We then attempt to clarify the role of laryngeal mask in air way management during anesthesia, discussing the advantages and disadvantages as well as indications and contraindications of its use in oral and maxillofacial surgery.

  7. Novel surgical technique for complete traumatic rupture of the pancreas: A case report

    Directory of Open Access Journals (Sweden)

    Jauch Karl-Walter

    2011-09-01

    Full Text Available Abstract Introduction Complete pancreatic rupture is a rare injury. The typical mechanism by which this occurs is overstretching of the pancreas across the vertebral column during blunt abdominal trauma. The management of this injury depends on the location and extent of the injury. Case presentation A 45-year-old Caucasian woman presented with blunt abdominal trauma after she fell onto the end of a handlebar during a bicycle accident. She arrived in the emergency room with stable vital signs and an isolated bruise just above the umbilicus. A computed tomography scan revealed a complete rupture of the pancreas, just ventral to her superior mesenteric vein, and an accompanying hematoma but no additional injuries. An emergency laparotomy was performed; the head of the pancreas was oversewn with interrupted sutures and this was followed by a two-layer pancreaticojejunostomy with the tail of the pancreas. The recovery after surgery was completely uneventful. Conclusions Isolated complete pancreatic rupture is a rare injury that can be managed with complete organ preservation. The combination of suturing the pancreatic head and two-layer pancreaticojejunostomy with the pancreatic tail is a feasible technique to manage this condition.

  8. Novel Techniques with the Aid of a Staged CBCT Guided Surgical Protocol

    Directory of Open Access Journals (Sweden)

    Evdokia Chasioti

    2015-01-01

    Full Text Available The case report will present some novel techniques for using a “staged” protocol utilizing strategic periodontally involved teeth as transitional abutments in combination with CBCT guided implant surgery. Staging the case prevented premature loading of the grafted sites during the healing phase. A CBCT following a tenting screw guided bone regeneration procedure ensured adequate bone to place an implant fixture. Proper assessment of the CBCT allowed the surgeon to do an osteotome internal sinus lift in an optimum location. The depth of the bone needed for the osteotome sinus floor elevation was planned. The staged appliance allowed these sinus-augmented sites to heal for an extended period of time compared to implants, which were uncovered and loaded at an earlier time frame. The staged protocol and CBCT analysis enabled the immediate implants to be placed in proper alignment to the adjacent fixture. After teeth were extracted, the osseointegrated implants were converted to abutments for the transitional appliance. Finally, the staged protocol allowed for soft tissue enhancement in the implant and pontic areas prior to final insertion of the prosthesis.

  9. Minimally invasive surgical technique: Percutaneous external fixation combined with titanium elastic nails for selective treatment of tibial fractures.

    Science.gov (United States)

    Tu, Kai-Kai; Zhou, Xian-Ting; Tao, Zhou-Shan; Chen, Wei-Kai; Huang, Zheng-Liang; Sun, Tao; Zhou, Qiang; Yang, Lei

    2015-12-01

    Several techniques have been described to treat tibial fractures, which respectively remains defects. This article presents a novel intra- and extramedullary fixation technique: percutaneous external fixator combined with titanium elastic nails (EF-TENs system). The purpose of this study is to introduce this new minimally invasive surgical technique and selective treatment of tibial fractures, particularly in segmental fractures, diaphysis fractures accompanied with distal or proximal bone subfissure, or fractures with poor soft-tissue problems. Following ethical approval, thirty-two patients with tibial fractures were treated by the EF-TENs system between January 2010 and December 2012. The follow-up studies included clinical and radiographic examinations. All relevant outcomes were recorded during follow-up. All thirty-two patients were achieved follow-ups. According to the AO classification, 3 Type A, 9 Type B and 20 Type C fractures were included respectively. According to the Anderson-Gustilo classification, there were 5 Type Grade II, 3 Type Grade IIIA and 2 Type Grade IIIB. Among 32 patients, 8 of them were segmental fractures. 12 fractures accompanied with bone subfissure. Results showed no nonunion case, with an average time of 23.7 weeks (range, 14-32 weeks). Among them, there were 3/32 delayed union patients and 0/32 malunion case. 4/32 patients developed a pin track infection and no patient suffered deep infection. The external fixator was removed with a mean time of 16.7 weeks (range, 10-26 weeks). Moreover, only 1/32 patient suffered with the restricted ROM of ankle, none with the restricted ROM of knee. This preliminary study indicated that the EF-TENs system, as a novel intra- and extramedullary fixation technique, had substantial effects on selective treatment of tibial fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Applying industrial process improvement techniques to increase efficiency in a surgical practice.

    Science.gov (United States)

    Reznick, David; Niazov, Lora; Holizna, Eric; Siperstein, Allan

    2014-10-01

    The goal of this study was to examine how industrial process improvement techniques could help streamline the preoperative workup. Lean process improvement was used to streamline patient workup at an endocrine surgery service at a tertiary medical center utilizing multidisciplinary collaboration. The program consisted of several major changes in how patients are processed in the department. The goal was to shorten the wait time between initial call and consult visit and between consult and surgery. We enrolled 1,438 patients enrolled in the program. The wait time from the initial call until consult was reduced from 18.3 ± 0.7 to 15.4 ± 0.9 days. Wait time from consult until operation was reduced from 39.9 ± 1.5 to 33.9 ± 1.3 days for the overall practice and to 15.0 ± 4.8 days for low-risk patients. Patient cancellations were reduced from 27.9 ± 2.4% to 17.3 ± 2.5%. Overall patient flow increased from 30.9 ± 5.1 to 52.4 ± 5.8 consults per month (all P process improvement methodology, surgery patients can benefit from an improved, streamlined process with significant reduction in wait time from call to initial consult and initial consult to surgery, with reduced cancellations. This generalized process has resulted in increased practice throughput and efficiency and is applicable to any surgery practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Basal cell carcinoma of the outer nose: Overview on surgical techniques and analysis of 312 patients

    Directory of Open Access Journals (Sweden)

    Uwe Wollina

    2014-01-01

    Full Text Available Background: Basal cell carcinoma of the nose is common, with a potential of local recurrence and high-risk features. Materials and Methods: We provide a review on anatomy of the nose, tumour surgery and defect closure on the nose. We analysed our own patients with nasal BCC of a 24 months period. Results: We identified 321 patients with nasal BCC. There was a predominance of female patients of 1.2 to 1. The mean age was 74.8 years. Slow Mohs technique was employed for all tumours until 3D tumour-free margins were achieved. That resulted on average in 1.8 ± 0.7 Mohs stages. The most common histologic types were solitary (n = 182, morpheic (79, and micronodular (20, Perineural infiltration was evident in 56 tumours. Primary closure after mobilisation of soft tissue was possible in 105 BCCs. Advancement flaps were used in 91 tumours, rotation flaps in 47, transposition flaps in 34 tumours, and combined procedures in 6 cases. In 36 patients full-thickness skin grafting was performed. In two patients healing by second intention was preferred. Partial flap loss was seen in four patients (1.4%. All of them had significant underlying pathologies. None of the tumours treated showed a relapse during the observation time. However, this is a limitation of the present study since follow-up was on average only 10 months. Conclusions: BCCs of the nose are common. Only 3D-controlled micrographic surgery (Mohs or slow Mohs guarantee a high rate of complete tumour removal and a very low risk of recurrence.

  12. The application of data measurement before the pedicle vertebral arch fixed operation with spiral CT

    International Nuclear Information System (INIS)

    Yang Zenian; Luo Zhongyao; Chen Yong'an

    2003-01-01

    Objective: Authors carry out volume scans and 3D surface reconstruction. Then authors get the precise data of pedicle of vertebral arch, entering nail angle on horizontal direction, entering nail screw length, and the smallest horizontal diameter and entering nails' distance on pedicle of vertebral arch before the pedicle vertebral arch fixed operation. Method: Select the axial image of the widest pedicle of vertebral arch and it SSD image, measure the entering nail distance on the pedicle of vertebral arch, TSA, entering nail screw length, and the smallest horizontal diameter of the pedicle of vertebral arch. Result: The method helps to prepare the length, size and location of the nail and TSA for the pedicle of vertebral arch fixed operation, increase the operation success rate. Conclusion: This is a simple and reliable method to prepare the precise data of the nail length and size, TSA for the operation

  13. scrotal reconstruction with a pedicled gracilis muscle flap after

    African Journals Online (AJOL)

    nonviable tissue is removed and a granulation bed suitable for .... The pedicled or free greater omental flap as well as scrotal tissue ... Bien-keem Tan, Mohammed ZulfikarRasheed,. WofflesT.L.Wu ... Honda Hsu Chih Ming Lin, Tzong-Bon Sun,.

  14. The use of pedicled prepucial skin flap urethroplasty for proximal ...

    African Journals Online (AJOL)

    The use of pedicled prepucial skin flap urethroplasty for proximal bulbomembraneous urethral stricture in children: an easy alternative to transpubic urethroplasty. Harshjeet S. Bal, Jujju J. Kurian and Sudipta Sen. Objective Pediatric urethral strictures are not uncommon, and a myriad of treatment options is available.

  15. The Use of Percutaneous Lumbar Fixation Screws for Bilateral Pedicle Fractures with an Associated Dislocation of a Lumbar Disc Prosthesis

    Directory of Open Access Journals (Sweden)

    William D. Harrison

    2013-01-01

    Full Text Available Study Design. Case report. Objective. To identify a safe technique for salvage surgery following complications of total disc replacement. Summary of Background Data. Lumbar total disc replacement (TDR is considered by some as the gold standard for discogenic back pain. Revision techniques for TDR and their complications are in their infancy. This case describes a successful method of fixation for this complex presentation. Methods and Results. A 48-year-old male with lumbar degenerative disc disease and no comorbidities. Approximately two weeks postoperatively for a TDR, the patient represented with acute severe back pain and the TDR polyethylene inlay was identified as dislocated anteriorly. Subsequent revision surgery failed immediately as the polyethylene inlay redislocated intraoperatively. Further radiology identified bilateral pedicle fractures, previously unseen on the plain films. The salvage fusion of L5/S1 reutilized the anterior approach with an interbody fusion cage and bone graft. The patient was then turned intraoperatively and redraped. The percutaneous pedicle screws were used to fix L5 to the sacral body via the paracoccygeal corridor. Conclusion. The robust locking screw in the percutaneous screw allowed a complete fixation of the pedicle fractures. At 3-year followup, the patient has an excellent result and has returned to playing golf.

  16. Comparação do poder de correção do instrumental de Luque-Galveston e do parafuso pedicular no tratamento cirúrgico da escoliose neuromuscular Comparación del poder de corrección del instrumental de Luque-Galveston y del tornillo pedicular en el tratamiento quirúrgico de la escoliosis neuromuscular Comparison between deformity correction of Luque-Galveston instrumentation and pedicle screw fixation in the surgical treatment of neuromuscular scoliosis

    Directory of Open Access Journals (Sweden)

    Murilo Tavares Daher

    2009-06-01

    (p=0.045. CONCLUSIONS: postoperative major curve correction was similar with pedicle screws and Luque-Galveston instrumentation, but pelvic obliquity correction was greater when pedicle screw was used in the surgical treatment of neuromuscular scoliosis.

  17. Clinical results of a surgical technique using endobuttons for complete tendon tear of pectoralis major muscle: report of five cases

    Directory of Open Access Journals (Sweden)

    Uchiyama Yoshiyasu

    2011-09-01

    Full Text Available Abstract Background We herein describe a surgical technique for the repair of complete tear of the pectoralis major (PM tendon using endobuttons to strengthen initial fixation. Methods Five male patients (3 judo players, 1 martial arts player, and 1 body builder were treated within 2 weeks of sustaining complete tear of the PM tendon. Average age at surgery and follow-up period were 28.4 years (range, 23-33 and 28.8 months (range, 24-36. A rectangular bone trough (about 1 × 4 cm was created on the humerus at the insertion of the distal PM tendon. The tendon stump was introduced into this trough, and fixed to the reverse side of the humeral cortex using endobuttons and non-absorbable suture. Clinical assessment of re-tear was examined by MRI. Shoulder range of motion (ROM, outcome of treatment, and isometric power were measured at final follow-up. Results There were no clinical re-tears, and MRI findings also showed continuity of the PM tendon in all cases at final follow-up. Average ROM did not differ significantly between the affected and unaffected shoulders. The clinical outcomes at final follow-up were excellent (4/5 cases or good (1/5. In addition, postoperative isometric power in horizontal flexion of the affected shoulder showed complete recovery when compared with the unaffected side. Conclusions Satisfactory outcomes could be obtained when surgery using the endobutton technique was performed within 2 weeks after complete tear of the PM tendon. Therefore, our new technique appears promising as a useful method to treat complete tear of the PM tendon.

  18. Prospective Study of the Surgical Techniques Used in Primary Rhinoplasty on the Caucasian Nose and Comparison of the Preoperative and Postoperative Anthropometric Nose Measurements

    Science.gov (United States)

    Berger, Cezar Augusto Sarraf; Freitas, Renato da Silva; Malafaia, Osvaldo; Pinto, José Simão de Paula; Macedo Filho, Evaldo Dacheux; Mocellin, Marcos; Fagundes, Marina Serrato Coelho

    2014-01-01

    Introduction The knowledge and study of surgical techniques and anthropometric measurements of the nose make possible a qualitative and quantitative analysis of surgical results. Objective Study the main technique used in rhinoplasty on Caucasian noses and compare preoperative and postoperative anthropometric measurements of the nose. Methods A prospective study with 170 patients was performed at a private hospital. Data were collected using the Electronic System Integrated of Protocols software (Sistema Integrado de Protocolos Eletrônicos, SINPE©). The surgical techniques used in the nasal dorsum and tip were evaluated. Preoperative and 12-month follow-up photos as well as the measurements compared with the ideal aesthetic standard of a Caucasian nose were analyzed objectively. Student t test and standard deviation test were applied. Results There was a predominance of endonasal access (94.4%). The most common dorsum technique was hump removal (33.33%), and the predominance of sutures (24.76%) was observed on the nasal tip, with the lateral intercrural the most frequent (32.39%). Comparison between preoperative and postoperative photos found statistically significant alterations on the anthropometric measurements of the noses. Conclusion The main surgical techniques on Caucasian noses were evaluated, and a great variety was found. The evaluation of anthropometric measurements of the nose proved the efficiency of the performed procedures. PMID:25992149

  19. Prospective Study of the Surgical Techniques Used in Primary Rhinoplasty on the Caucasian Nose and Comparison of the Preoperative and Postoperative Anthropometric Nose Measurements

    Directory of Open Access Journals (Sweden)

    Berger, Cezar Augusto Sarraf

    2014-12-01

    Full Text Available Introduction The knowledge and study of surgical techniques and anthropometric measurements of the nose make possible a qualitative and quantitative analysis of surgical results. Objective Study the main technique used in rhinoplasty on Caucasian noses and compare preoperative and postoperative anthropometric measurements of the nose. Methods A prospective study with 170 patients was performed at a private hospital. Data were collected using the Electronic System Integrated of Protocols software (Sistema Integrado de Protocolos Eletrônicos, SINPE©. The surgical techniques used in the nasal dorsum and tip were evaluated. Preoperative and 12-month follow-up photos as well as the measurements compared with the ideal aesthetic standard of a Caucasian nose were analyzed objectively. Student t test and standard deviation test were applied. Results There was a predominance of endonasal access (94.4%. The most common dorsum technique was hump removal (33.33%, and the predominance of sutures (24.76% was observed on the nasal tip, with the lateral intercrural the most frequent (32.39%. Comparison between preoperative and postoperative photos found statistically significant alterations on the anthropometric measurements of the noses. Conclusion The main surgical techniques on Caucasian noses were evaluated, and a great variety was found. The evaluation of anthropometric measurements of the nose proved the efficiency of the performed procedures.

  20. Surgical orthodontics.

    Science.gov (United States)

    Strohl, Alexis M; Vitkus, Lauren

    2017-08-01

    The article reviews some commonly used orthodontic treatments as well as new strategies to assist in the correction of malocclusion. Many techniques are used in conjunction with surgical intervention and are a necessary compliment to orthognathic surgery. Basic knowledge of these practices will aid in the surgeon's ability to adequately treat the patient. Many orthodontists and surgeons are eliminating presurgical orthodontics to adopt a strategy of 'surgery first' orthodontics in orthognathic surgery. This has the benefit of immediate improvement in facial aesthetics and shorter treatment times. The advent of virtual surgical planning has helped facilitate the development of this new paradigm by making surgical planning faster and easier. Furthermore, using intraoperative surgical navigation is improving overall precision and outcomes. A variety of surgical and nonsurgical treatments may be employed in the treatment of malocclusion. It is important to be familiar with all options available and tailor the patient's treatment plan accordingly. Surgery-first orthodontics, intraoperative surgical navigation, virtual surgical planning, and 3D printing are evolving new techniques that are producing shorter treatment times and subsequently improving patient satisfaction without sacrificing long-term stability.

  1. [Exploratory study of 3D printing technique in the treatment of basilar invagination and atlantoaxial dislocation].

    Science.gov (United States)

    Yin, Yiheng; Yu, Xinguang; Tong, Huaiyu; Xu, Tao; Wang, Peng; Qiao, Guangyu

    2015-10-06

    To investigate the clinical application value of the 3D printing technique in the treatment of basilar invagination and atlantoaxial dislocation. From January 2013 to September 2013, 10 patients with basilar invagination and atlantoaxial dislocation needing posterior fixation undertook 3D printing modes at the Department of Neurosurgery in PLA General Hospital. The 1:1 size models were established from skull base to C4 level with different colors between bone structures and vertebral arteries. The simulation of screw insertion was made to investigate the fixation plan and ideal entry point to avoid vertebral artery injury. After obtaining the individual screw insertion data in 3D printing modes, the according surgical operations were performed. The actual clinical results and virtual screw data in 3D printing mode were compared with each other. The 3D printing modes revealed that all the 10 patients had the dysplasia or occipitalized C1 posterior arch indicating C1 posterior arch screw implantation was not suitable. C1 lateral masses were chosen as the screws entry points. C2 screws were designed individually based on the 3D printing modes as follows: 3 patients with aberrant vertebral artery or narrow C2 pedicle less than 3.5 mm were not suitable for pedicle screw implantation. Among the 3 patients, 1 was fixed with C2 laminar screw, and 1 with C2-3 transarticular screw and 1 with C3 pedicle screw (also combined with congenital C2-3 vertebral fusion). Two patients with narrow C2 pedicle between 3.5 and 4mm were designed to choose pedicle screw fixation after 3D printing mode evaluation. One patient with C1 lateral mass vertically dislocated axis was planned with C1-2 transarticular screw fixation. All the other patients were planned with C2 pedicle screws. All the 10 patients had operation designed as the 3D printing modes schemes. The follow-up ranged from 12 to 18 months and all the patients recovered from the clinical symptoms and the bony fusion attained to

  2. Surgical stabilization of rib fractures using Inion OTPS wraps--techniques and quality of life follow-up.

    Science.gov (United States)

    Campbell, Nicole; Conaglen, Paul; Martin, Katherine; Antippa, Phillip

    2009-09-01

    A variety of operative techniques have been described in the past for the surgical stabilization of fractured ribs. From February 2004 to November 2008, consecutive patients who underwent open reduction and internal fixation of traumatic fractured ribs during their index admission using the Inion orthopedic trauma plating system (OTPS) at a Level I trauma center were retrospectively analyzed. Demographics, Injury Severity Scores, number and site of rib fractures, operative details, and complications were recorded. All patients were followed-up with a questionnaire assessing chest symptoms, disability, and quality of life. Thirty-two patients underwent surgical stabilization with Inion OTPS. Road crashes were the commonest mechanism of injury (81%), followed by falls. Seventy-two percent of patients were male, with a median age at operation of 53 years (interquartile range [IQR], 40-64 years). Median number of ribs fixed was 3 (IQR, 2-4), while median number of fractures was 9 (IQR, 6-13). Median time to fixation was 5 days (IQR, 3-7 days), intensive care unit stay 3 days (IQR, 0.8-6.3 days), and total hospital stay 13.5 days (IQR, 8.8-22 days). Wound infection occurred in 19%, with nonunion of a fixed fracture in one patient. Sixty-three percent of patients completed the survey with a mean time between open reduction and internal fixation and questionnaire of 1,039 days (+/-480 days). Patients reported low levels of pain at rest and with coughing (median at rest 1.0/10 [IQR, 0-2.3/10]; with coughing 1.3/10 [IQR, 0-3.75/10]). Chest wall stiffness was experienced by 60% of patients, while dyspnoea at rest was reported by 20% of patients. Mean return to work (for 55%) was 3.9 months (+/-3.3 months). All patients were satisfied with the results of their operation. Patients demonstrated low levels of pain and satisfactory rehabilitation. The Inion OTPS system has several advantages including gradual transference of stress loads to bone, micromotion across the fracture

  3. Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength

    Energy Technology Data Exchange (ETDEWEB)

    Wichmann, Julian L.; Booz, Christian; Bauer, Ralf W.; Kerl, J.M.; Fischer, Sebastian; Lehnert, Thomas; Vogl, Thomas J.; Khan, M.F. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Wesarg, Stefan [Fraunhofer IGD, Cognitive Computing and Medical Imaging, Darmstadt (Germany); Kafchitsas, Konstantinos [Spine Center, Asklepios Klinik Lindenlohe, Schwandorf (Germany)

    2015-06-01

    To evaluate quantitative dual-energy computed tomography (DECT) for phantomless analysis of cancellous bone mineral density (BMD) of vertebral pedicles and to assess the correlation with pedicle screw pull-out strength. Twenty-nine thoracic and lumbar vertebrae from cadaver specimens were examined with DECT. Using dedicated post-processing software, a pedicle screw vector was mapped (R1, intrapedicular segment of the pedicle vector; R2, intermediate segment; R3, intracorporal segment; global, all segments) and BMD was calculated. To invasively evaluate pedicle stability, pedicle screws were drilled through both pedicles and left pedicle screw pull-out strength was measured. Resulting values were correlated using the paired t test and Pearson's linear correlation. Average pedicle screw vector BMD (R1, 0.232 g/cm{sup 3}; R2, 0.166 g/cm{sup 3}; R3, 0.173 g/cm{sup 3}; global, 0.236 g/cm{sup 3}) showed significant differences between R1-R2 (P < 0.002) and R1-R3 (P < 0.034) segments while comparison of R2-R3 did not reach significance (P > 0.668). Average screw pull-out strength (639.2 N) showed a far stronger correlation with R1 (r = 0.80; P < 0.0001) than global BMD (r = 0.42; P = 0.025), R2 (r = 0.37; P = 0.048) and R3 (r = -0.33; P = 0.078) segments. Quantitative DECT allows for phantomless BMD assessment of the vertebral pedicle. BMD of the intrapedicular segment shows a significantly stronger correlation with pedicle screw pull-out strength than other segments. (orig.)

  4. OPEN SURGICAL VS. MINIMALLY INVASIVE TREATMENT OF THORACOLUMBAR AO FRACTURES TYPE A AND B1 IN A REFERENCE HOSPITAL

    Directory of Open Access Journals (Sweden)

    José Enrique Salcedo Oviedo

    Full Text Available ABSTRACT Objective: The thoracolumbar spine trauma represents 30% of spinal diseases. To compare the minimally invasive technique with the open technique in lumbar fractures. Method: A prospective, cross-sectional, comparative observational study, which evaluated the following variables: surgery time, length of hospital stay, transoperative bleeding, postoperative pain, analyzed by SPSS software using Student's t test with statistical significance of p ≥ 0.05, with 24 patients with single-level thoracolumbar fractures, randomly treated with percutaneous pedicle screws and by open technique with a transpedicular system. Results: The surgery time was 90 minutes for the minimally invasive technique and 60 minutes for the open technique, the bleeding was on average 50 cm3 vs. 400 cm3. The mean visual analogue scale for pain at 24 hours of surgery was 5 for the minimally invasive group vs. 8 for the open group. The number of fluoroscopic projections of pedicle screws was 220 in the minimally invasive technique vs. 100 in the traditional technique. Quantified bleeding was minimal for percutaneous access vs. 340 cm3 for the traditional system. The hospital discharge for the minimally invasive group was at 24 hours and at 72 hours for those treated with open surgery. Conclusions: It is a technique that requires longer surgical time, with reports of less bleeding, less postoperative pain and less time for hospital discharge, reasons why it is supposed to be a procedure that requires a learning curve, statistical significance with respect to bleeding, visual analogue scale for pain and showed no significant difference in the variables of surgical time.

  5. Ball tip method for thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis

    International Nuclear Information System (INIS)

    Watanabe, Kota; Matsumoto, Morio; Iizuka, Shingo

    2008-01-01

    The purpose of this study was to evaluate the efficacy of ball tip method for thoracic pedicle screw placements in idiopathic scoliosis patients. 24 patients with adolescent idiopathic scoliosis were included in this study. Conventional method was performed in 12 patients. Ball tip method was performed in 12 patients. Accuracy of the pedicle screw placement was evaluated based on the postoperative CT. In the ball tip method, a probe which was consisted of ball tip with flexible shaft was used. After removing of cortical bone at a starting point, the probe was inserted manually or sometimes with gently tapping by hammer. During the maneuver, the probe will gradually progress into cancellous bone in the pedicle, without perforating cortical bone in the pedicle. Following expansion of the hole by a rigid gear shift probe, screw was placed in the pedicle. 65.1% of screws were located within pedicle in the conventional group and 86.5% in the ball tip group. 5.3% of screws were located out of pedicle within 2 mm in the conventional group and 8.2% in the ball tip group. 15.8% of screws were located out of pedicle beyond 2 mm and 1.8% in the ball tip group. The ball tip method enhanced the accuracy of thoracic pedicle screw placements in adolescent idiopathic scoliosis patients. The ball tip method may be effective for accurate pedicle screw placement in patients with adolescent idiopathic scoliosis. (author)

  6. Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae - A cadaveric study

    Directory of Open Access Journals (Sweden)

    Shyam K Saraf

    2013-01-01

    Full Text Available Background: The objective of this cadaveric study was to analyze the effects of iatrogenic pedicle perforations from screw misplacement on the mean pullout strength of lower thoracic and lumbar pedicle screws. We also investigated the effect of bone mineral density (BMD, diameter of pedicle screws, and the region of spine on the pullout strength of pedicle screws. Materials and Methods: Sixty fresh human cadaveric vertebrae (D10-L2 were harvested. Dual-energy X-ray absorptiometry (DEXA scan of vertebrae was done for BMD. Titanium pedicle screws of different diameters (5.2 and 6.2 mm were inserted in the thoracic and lumbar segments after dividing the specimens into three groups: a standard pedicle screw (no cortical perforation; b screw with medial cortical perforation; and c screw with lateral cortical perforation. Finally, pullout load of pedicle screws was recorded using INSTRON Universal Testing Machine. Results: Compared with standard placement, medially misplaced screws had 9.4% greater mean pullout strength and laterally misplaced screws had 47.3% lesser mean pullout strength. The pullout strength of the 6.2 mm pedicle screws was 33% greater than that of the 5.2 mm pedicle screws. The pullout load of pedicle screws in lumbar vertebra was 13.9% greater than that in the thoracic vertebra ( P = 0.105, but it was not statistically significant. There was no significant difference between pullout loads of vertebra with different BMD ( P = 0.901. Conclusion: The mean pullout strength was less with lateral misplaced pedicle screws while medial misplaced pedicle screw had more pullout strength. The pullout load of 6.2 mm screws was greater than that of 5.2 mm pedicle screws. No significant correlation was found between bone mineral densities and the pullout strength of vertebra. Similarly, the pullout load of screw placed in thoracic and lumbar vertebrae was not significantly different.

  7. Intermediate-Term Outcomes of Dual Adult versus Single-Kidney Transplantation: Evolution of a Surgical Technique

    Directory of Open Access Journals (Sweden)

    Ana K. Islam

    2016-01-01

    Full Text Available Background. Acceptance of dual kidney transplantation (DKT has proven difficult, due to surgical complexity and concerns regarding long-term outcomes. We herein present a standard technique for ipsilateral DKT and compare outcomes to single-kidney transplant (SKT recipients. Methods. A retrospective single-center comparison of DKT and SKT performed between February 2007 and July 2013. Results. Of 516 deceased donor kidney transplants, 29 were DKT and 487 were SKT. Mean follow-up was 43 ± 67 months. DKT recipients were older and more likely than SKT recipients to receive an extended criteria graft (p<0.001. For DKT versus SKT, the rates of delayed graft function (10.3 versus 9.2% and acute rejection (20.7 versus 22.4% were equivalent (p = ns. A higher than expected urologic complication rate in the DKT cohort (14 versus 2%, p<0.01 was reduced through modification of the ureteral anastomosis. Graft survival was equivalent between DKT and SKT groups (p = ns with actuarial 3-year DKT patient and graft survivals of 100% and 93%. At 3 years, the groups had similar renal function (p = ns. Conclusions. By utilizing extended criteria donor organs as DKT, the donor pool was enlarged while providing excellent patient and graft survival. The DKT urologic complication rate was reduced by modification of the ureteral anastomosis.

  8. Intermediate-Term Outcomes of Dual Adult versus Single-Kidney Transplantation: Evolution of a Surgical Technique.

    Science.gov (United States)

    Islam, Ana K; Knight, Richard J; Mayer, Wesley A; Hollander, Adam B; Patel, Samir; Teeter, Larry D; Graviss, Edward A; Saharia, Ashish; Podder, Hemangshu; Asham, Emad H; Gaber, A Osama

    2016-01-01

    Background. Acceptance of dual kidney transplantation (DKT) has proven difficult, due to surgical complexity and concerns regarding long-term outcomes. We herein present a standard technique for ipsilateral DKT and compare outcomes to single-kidney transplant (SKT) recipients. Methods. A retrospective single-center comparison of DKT and SKT performed between February 2007 and July 2013. Results. Of 516 deceased donor kidney transplants, 29 were DKT and 487 were SKT. Mean follow-up was 43 ± 67 months. DKT recipients were older and more likely than SKT recipients to receive an extended criteria graft (p DKT versus SKT, the rates of delayed graft function (10.3 versus 9.2%) and acute rejection (20.7 versus 22.4%) were equivalent (p = ns). A higher than expected urologic complication rate in the DKT cohort (14 versus 2%, p DKT and SKT groups (p = ns) with actuarial 3-year DKT patient and graft survivals of 100% and 93%. At 3 years, the groups had similar renal function (p = ns). Conclusions. By utilizing extended criteria donor organs as DKT, the donor pool was enlarged while providing excellent patient and graft survival. The DKT urologic complication rate was reduced by modification of the ureteral anastomosis.

  9. Management of Excessive Weight Loss Following Laparoscopic Roux-en-Y Gastric Bypass: Clinical Algorithm and Surgical Techniques.

    Science.gov (United States)

    Akusoba, Ikemefuna; Birriel, T Javier; El Chaar, Maher

    2016-01-01

    There are no clinical guidelines or published studies addressing excessive weight loss and protein calorie malnutrition following a standard Roux-en-Y gastric bypass (RYGB) to guide nutritional management and treatment strategies. This study demonstrates the presentation, clinical algorithm, surgical technique, and outcomes of patients afflicted and successfully treated with excessive weight loss following a standard RYGB. Three patients were successfully reversed to normal anatomy after evaluation, management, and treatment by multidisciplinary team. Lowest BMI (kg/m(2)) was 18.9, 17.9, and 14.2, respectively. Twelve-month post-operative BMI (kg/m(2)) was 28.9, 22.8, and 26.1, respectively. Lowest weight (lbs) was 117, 128, and 79, respectively. Twelve-month post-operative weight (lbs) was 179, 161, and 145, respectively. Pre-reversal gastrostomy tube was inserted into the remnant stomach to demonstrate weight gain and improve nutritional status prior to reversal to original anatomy. We propose a practical clinical algorithm for the work-up and management of patients with excessive weight loss and protein calorie malnutrition after standard RYGB including reversal to normal anatomy.

  10. Comparison of four surgical techniques for management of pseudophakic and aphakic retinal detachment: a multicenter clinical trial.

    Science.gov (United States)

    Moradian, Siamak; Ahmadieh, Hamid; Faghihi, Hooshang; Ramezani, Alireza; Entezari, Morteza; Banaee, Touka; Heidari, Ebadollah; Behboudi, Hassan; Yasseri, Mehdi

    2016-09-01

    To compare the visual and anatomical outcomes of four surgical techniques to manage pseudophakic and aphakic retinal detachment (PARD). In a multicenter randomized clinical trial, 211 eyes of 211 patients with PARD and proliferative vitreoretinopathy (PVR) grade B or less were randomly assigned to one of the four treatment groups: (1) scleral buckling (SB), 50 eyes, (2) vitrectomy without band, 51 eyes, (3) vitrectomy with encircling band (EB), 58 eyes, and (4) triamcinolone acetonide (TA) assisted vitrectomy, 52 eyes. Patients were followed for 12 months after the surgery. The best-corrected visual acuity (BCVA) and retinal reattachment rate at each follow-up time point were considered as the primary outcome measures. PVR, macular pucker, and cystoid macular edema were considered as the secondary outcomes. Visual improvement was achieved in all treatment groups relative to the baseline at all time points (all Ps  0.99). There were no statistically significant differences among the groups in terms of adverse events. SB, TA-assisted vitrectomy, and vitrectomy with and without buckle had comparable outcomes in the management of PARD.

  11. [Liver transplantation--indications, surgical technique, results--the analysis of a clinical series of 200 cases].

    Science.gov (United States)

    Popescu, I; Ionescu, M; Braşoveanu, V; Hrehoreţ, D; Matei, E; Dorobantu, B; Zamfir, R; Alexandrescu, S; Grigorie, M; Tulbure, D; Popa, L; Ungureanu, M; Tomescu, D; Droc, G; Popescu, H; Cristea, A; Gheorghe, L; Iacob, S; Gheorghe, C; Boroş, M; Lupescu, I; Vlad, L; Herlea, V; Croitoru, M; Platon, P; Alloub, A

    2010-01-01

    Initially considered experimental, liver transplantation (LT) has become the treatment of choice for the patients with end-stage liver diseases. Between April 2000 and October 2009, 200 LTs (10 reLTs) were performed in 190 patients, this study being retrospective. There were transplanted 110 men and 80 women, 159 adults and 31 children with the age between 1 and 64 years old (mean age--39.9). The main indication in the adult group was represented by viral cirrhosis, while the pediatric series the etiology was mainly glycogenosis and biliary atresia. There were performed 143 whole graft LTs, 46 living donor LTs, 6 split LTs, 4 reduced LTs and one domino LT RESULTS: The postoperative survival was 90% (170 patients). The patient and graft one-year and five-year survivals were 76.9%, 73.6% and 71%, 68.2%, respectively. The early complications occurred in 127 patients (67%). The late complications were recorded in 71 patients (37.3%). The intraoperative and early postoperative mortality rate was 9.5% (18 patients). The Romanian liver transplantation program from Fundeni includes all types of current surgical techniques and the results are comparable with those from other international centers.

  12. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study.

    NARCIS (Netherlands)

    Tabassum, A.; Meijer, G.J.; Wolke, J.G.C.; Jansen, J.A.

    2009-01-01

    OBJECTIVE: The aim of this biomechanical study was to assess the effect of surgical technique and surface roughness on primary implant stability in low-density bone. MATERIAL AND METHODS: Eighty screw-shaped (Biocomp) implants with machined or etched surface topography were inserted into a

  13. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.

    NARCIS (Netherlands)

    Tabassum, A.; Meijer, G.J.; Wolke, J.G.C.; Jansen, J.A.

    2010-01-01

    OBJECTIVE: The aim of this biomechanical study was to assess the interrelated effect of both surface roughness and surgical technique on the primary stability of dental implants. MATERIAL AND METHODS: For the experiment, 160 screw-designed implants (Biocomp), with either a machined or an etched

  14. Achieving a predictable 24-hour return to normal activities after breast augmentation: part II. Patient preparation, refined surgical techniques, and instrumentation.

    Science.gov (United States)

    Tebbetts, John B

    2006-12-01

    The goal of this study was to develop practices that would allow patients undergoing subpectoral augmentation to predictably return to full normal activities within 24 hours after the operation, free of postoperative adjuncts. Part I of this study used motion and time study principles to reduce operative times, medication dosages, perioperative morbidity, and recovery times in augmentation mammaplasty. Part II of the study focuses on details of patient education, preoperative planning, instrumentation, and surgical technique modifications that were identified, modified, and implemented to achieve the results reported in part I. Two groups of 16 patients each (groups 1 and 2) were studied retrospectively for comparison to a third group of 627 patients (group 3) studied prospectively. Patients in group 1 had axillary partial retropectoral breast augmentations in 1982-1983, using dissociative anesthesia, blunt instrument implant pocket dissection, and Dow Corning, double-lumen implants containing 20 mg of methylprednisolone and 20 cc of saline in the outer lumen of the implants. Patients in group 2 (1990) had inframammary, retromammary augmentations by using a combination of blunt and electrocautery dissection, Surgitek Replicon polyurethane-covered, silicone gel-filled implants, and general endotracheal anesthesia. Patients in group 3 (1998 to 2001, n = 627) had inframammary partial retropectoral, inframammary retromammary, and axillary partial retropectoral augmentations under general endotracheal anesthesia. Refined practices and surgical techniques from studies of groups 1 and 2 were applied in group 3. Videotapes from operative procedures of groups 1 and 2 were analyzed with macromotion and micromotion study principles, and tables of events were formulated for each move during the operation for all personnel in the operating room. Extensive details of surgical technique were examined and reexamined in 13 different stages by using principles of motion and time

  15. Spontaneus bilateral pedicle fracture 30 years after Harrington Instrumentation for idiopathic scoliosis: a case report

    Directory of Open Access Journals (Sweden)

    Obid Peter

    2012-01-01

    Full Text Available Abstract Introduction Spontaneous fractures of the spine are a common entity. They usually occur in older people with osteoporosis. This case is presented on account of its rarity. To the best of the authors' knowledge only one case of an osteoporotic pedicle fracture after Harrington Instrumentation has been described before. Case presentation We report the case of a 46-year-old Caucasian woman who underwent surgery due to idiopathic scoliosis with a Harrington Instrumentation (T4 to L3 30 years ago. During the operation she was infected with hepatitis C while receiving erythrocyte concentrates and has suffered from liver cirrhosis since then. She presented with a sudden pain in her lower back and paraesthesia in both her legs but no other neurological symptoms. A computed tomography scan showed a bilateral pedicle fracture of L3 and an additional compression fracture of L4. In the first session we performed a dorsal stabilization with massive intraoperative bleeding and a postoperative failure of liver synthesis. In a second session an additional ventral augmentation was done. After the second operation she developed a hepatorenal syndrome. Both operations left the patient in a very critical state which led to a prolonged stay in the intensive care and rehabilitation unit. At her 12-month follow-up visit, she was free of complaints. Conclusion The un-physiological load of the spine after Harrington Instrumentation can lead to osteoporosis due to inactivity even in younger patients. Although these implants are not used anymore one should keep this possibility in mind when dealing with patients who have received Harrington rods in surgical procedures.

  16. Heat generation during implant placement in low-density bone: effect of surgical technique, insertion torque and implant macro design.

    Science.gov (United States)

    Marković, Aleksa; Mišić, Tijana; Miličić, Biljana; Calvo-Guirado, Jose Luis; Aleksić, Zoran; Ðinić, Ana

    2013-07-01

    The study aimed to investigate the effect of surgical technique, implant macrodesign and insertion torque on bone temperature changes during implant placement. In the in vitro study, 144 self-tapping (blueSKY(®) 4 × 10 mm; Bredent) and 144 non-self-tapping (Standard implant(®) 4.1 × 10 mm; Straumann) were placed in osteotomies prepared in pig ribs by lateral bone condensing or bone drilling techniques. The maximum insertion torque values of 30, 35 and 40 Ncm were used. Real-time bone temperature measurement during implant placement was performed by three thermocouples positioned vertically, in tripod configuration around every osteotomy, at a distance of 5 mm from it and at depths of 1, 5 and 10 mm. Data were analysed using Kruskal-Wallis, Mann-Whitney U-tests and Regression analysis. Significant predictor of bone temperature at the osteotomy depth of 1 mm was insertion torque (P = 0.003) and at the depth of 10-mm implant macrodesign (P = 0.029), while no significant predictor at depth of 5 mm was identified (P > 0.05). Higher insertion torque values as well as non-self-tapping implant macrodesign were related to higher temperatures. Implant placement in sites prepared by bone drilling induced significantly higher temperature increase (P = 0.021) compared with bone condensing sites at the depth of 5 mm, while no significant difference was recorded at other depths. Compared with 30 Ncm, insertion torque values of 35 and 40 Ncm produced significantly higher temperature increase (P = 0.005; P = 0.003, respectively) at the depth of 1 mm. There was no significant difference in temperature change induced by 35 and 40 Ncm, neither by implant macrodesign at all investigated depths (P > 0.05). Placement of self-tapping implants with low insertion torque into sites prepared by lateral bone condensing technique might be advantageous in terms of thermal effect on bone. © 2012 John Wiley & Sons A/S.

  17. Experimental study of pedicle screw stability on low BMD vertebrae

    International Nuclear Information System (INIS)

    Li Qi; Yang Huilin; Tang Tiansi; Wu Yiwei; Wang Yijin

    2005-01-01

    Objective: To conduct biomechanical study of different pedicle screws stability on spinal specimen, discuss the relationship between design parameter of screw, insertion torgue and BMD, establish the theoretical foundation for application of pedicle screw on osteoporotic patients. Methods: Six fixed lumbar cadavers were collected, the effects of design parameter, insertion torque and etc on fixation stability were determined under various BMD by using biomechanical ways. Results: According to in vitro study: (1) There was a significant difference among pullout strength of all screws (P 2 >U 1 >SF 1 >SF 2 >RF. Conclusions: There is a close correlated between type of screw, BMD and stability. The U-type screw displays the best fixation effect on specimen of low BMD. (authors)

  18. Fatigue life prediction of pedicle screw for spinal surgery

    Czech Academy of Sciences Publication Activity Database

    Major, Štěpán; Kocour, Vladimír; Cyrus, P.

    2016-01-01

    Roč. 10, č. 35 (2016), s. 379-388 ISSN 1971-8993. [European Conference on Fracture. ECF21. Catania, 20.06.2015-20.06.2015] Institutional support: RVO:68378297 Keywords : pedicle-screw * titan alloy * fatigue life * finite element analysis Subject RIV: JK - Corrosion ; Surface Treatment of Materials http://www.fracturae.com/index.php/fis/article/view/IGF-ESIS.35.43

  19. Internal limiting membrane flap transposition for surgical repair of macular holes in primary surgery and in persistent macular holes.

    Science.gov (United States)

    Leisser, Christoph; Hirnschall, Nino; Döller, Birgit; Varsits, Ralph; Ullrich, Marlies; Kefer, Katharina; Findl, Oliver

    2018-03-01

    Classical or temporal internal limiting membrane (ILM) flap transposition with air or gas tamponade are current trends with the potential to improve surgical results, especially in cases with large macular holes. A prospective case series included patients with idiopathic macular holes or persistent macular holes after 23-G pars plana vitrectomy (PPV) and ILM peeling with gas tamponade. In all patients, 23-G PPV and ILM peeling with ILM flap transposition with gas tamponade and postoperative face-down position was performed. In 7 of 9 eyes, temporal ILM flap transposition combined with pedicle ILM flap could be successfully performed and macular holes were closed in all eyes after surgery. The remaining 2 eyes were converted to pedicle ILM flap transposition with macular hole closure after surgery. Three eyes were scheduled as pedicle ILM flap transposition due to previous ILM peeling. In 2 of these eyes, the macular hole could be closed with pedicle ILM flap transposition. In 3 eyes, free ILM flap transposition was performed and in 2 of these eyes macular hole could be closed after surgery, whereas in 1 eye a second surgery, performed as pedicle ILM flap transposition, was performed and led to successful macular hole closure. Use of ILM flaps in surgical repair of macular hole surgery is a new option of treatment with excellent results independent of the diameter of macular holes. For patients with persistent macular holes, pedicle ILM flap transposition or free ILM flap transposition are surgical options.

  20. ''The dermal internal brassiere flap,'' a new modification of inferior pedicle breast reduction technic.

    Science.gov (United States)

    Temel, Metin; Karakaş, Ali O; Dokuyucu, Recep; Türkmen, Arif

    2015-06-01

    The inferior pedicle mammaplasty is particularly applied to large breasts with a long sternal notch to nipple distance. The present study reports modifications developed to solve the bottoming-out deformity, the lack of upper pole fullness and the wound healing problems seen at the reverse T-zone, known disadvantages of the inferior pedicle reduction mammaplasty, and evaluates postoperative sensation. A total of 110 patients with a mean age of 32 underwent the same technique. In this technique, two pairs of quadrangular and triangular flaps were planned from the skin of resection sites. The triangular dermal flaps and quadrangular flaps were suspended from the periosteum of the 2nd and 4th ribs, respectively. The distance from the nipple to inframammary fold was measured at the postoperative 1st month and 1st year. In the postoperative period, a nipple-inframammary fold distance increase of over 2 cm was determined as bottoming-out deformity. Sensation evaluations were performed by subjective and objective tests. The mean sternal notch to nipple distance was 35.00 cm. After operation, the mean distance between the sternal notch and the nipple was 20.00 cm. NAC examination revealed normal sensation in all patients. Whereas the preoperative mean areolar threshold value was 36.70 g/mm(2), the postoperative first-year mean areolar pressure threshold value was 35.50 g/mm(2) (p value was 25.30 g/mm(2), whereas the postoperative first-year mean nipple pressure threshold value was 26.00 g/mm(2) (p = 0.5471). The postoperative first-month mean sternal notch to nipple distance value of the patients was 20.00 cm, whereas the postoperative first-year mean sternal notch to nipple distance value of the patients was 20.00 cm, (p = 0.0648). The postoperative first-month mean nipple to submammary fold distance value of the patients was 10.50 cm, the postoperative first-year mean nipple to submammary fold distance value of the patients was 11.00 cm (p disadvantages of the inferior

  1. A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine.

    Science.gov (United States)

    Merc, Matjaz; Drstvensek, Igor; Vogrin, Matjaz; Brajlih, Tomaz; Recnik, Gregor

    2013-07-01

    The method of free-hand pedicle screw placement is generally safe although it carries potential risks. For this reason, several highly accurate computer-assisted systems were developed and are currently on the market. However, these devices have certain disadvantages. We have developed a method of pedicle screw placement in the lumbar and sacral region using a multi-level drill guide template, created with the rapid prototyping technology and have validated it in a clinical study. The aim of the study was to manufacture and evaluate the accuracy of a multi-level drill guide template for lumbar and first sacral pedicle screw placement and to compare it with the free-hand technique under fluoroscopy supervision. In 2011 and 2012, a randomized clinical trial was performed on 20 patients. 54 screws were implanted in the trial group using templates and 54 in the control group using the fluoroscopy-supervised free-hand technique. Furthermore, applicability for the first sacral level was tested. Preoperative CT-scans were taken and templates were designed using the selective laser sintering method. Postoperative evaluation and statistical analysis of pedicle violation, displacement, screw length and deviation were performed for both groups. The incidence of cortex perforation was significantly reduced in the template group; likewise, the deviation and displacement level of screws in the sagittal plane. In both groups there was no significantly important difference in deviation and displacement level in the transversal plane as not in pedicle screw length. The results for the first sacral level resembled the main investigated group. The method significantly lowers the incidence of cortex perforation and is therefore potentially applicable in clinical practice, especially in some selected cases. The applied method, however, carries a potential for errors during manufacturing and practical usage and therefore still requires further improvements.

  2. L5 pedicle length is increased in subjects with spondylolysis: an anatomic study of 1072 cadavers.

    Science.gov (United States)

    Bajwa, Navkirat S; Toy, Jason O; Ahn, Nicholas U

    2012-11-01

    In spondylolisthesis, it is believed that as L5 slips on S1, the pedicle may become elongated in response to the instability in an attempt to bridge the defect. Whether patients with spondylolysis, which is largely developmental, also develop elongation of the pedicles is unknown. The purpose of this study is to evaluate and quantify the increase in L5 pedicle length in subjects with spondylolysis as compared with normal healthy subjects. Nine hundred fifty-two human cadaveric specimens without spondylolysis and 120 specimens with spondylolysis from the Hamann-Todd Osteological Collection were examined by a single examiner. Baseline data, including age, sex, and race of specimens, were collected. Digital calipers were used to measure the pedicle lengths at the L5 level. Linear regression analysis was performed to compare the L5 pedicle lengths in healthy patients and patients with spondylolysis. Linear regression showed a significant association of increased L5 pedicle length in subjects with spondylolysis. The average L5 pedicle length in subjects with spondylolysis was greater compared with subjects without spondylolysis. In spondylolytic specimens, pedicles start to elongate after the age of 40 years. The pedicle lengths increase progressively from 5.6 mm at 40 years to 6.7 mm at 80 years with a 1% to 3% increment every decade. The pedicle lengths showed little variation in specimens from healthy subjects. In spondylolytic specimens, there is progressive elongation of L5 pedicle length after the third decade. An increase in L5 pedicle length in all age groups compared with the specimens from healthy subjects suggests that pathologic changes occur in bony anatomy of L5 vertebrae as early as adolescence when the condition develops.

  3. Surgical treatment of choanal atresia with transnasal endoscopic approach with stentless single side-hinged flap technique: 5 year retrospective analysis

    Directory of Open Access Journals (Sweden)

    Carmelo Saraniti

    Full Text Available Abstract Introduction: Choanal atresia is a rare congenital malformation of the nasal cavity characterized by the complete obliteration of the posterior choanae. In 67% of cases choanal atresia is unilateral, affecting mainly (71% the right nasal cavity. In contrast to the unilateral form, bilateral choanal atresia is a life-threatening condition often associated with respiratory distress with feeding and intermittent cyanosis exacerbated by crying. Surgical treatment remains the only therapeutic option. Objective: To report our experience in the use of a transnasal endoscopic approach with stentless single side-hinged flap technique for the surgical management of choanal atresia. Methods: A 5 year retrospective analysis of surgical outcomes of 18 patients treated for choanal atresia with a transnasal technique employing a single side-hinged flap without stent placement. All subjects were assessed preoperatively with a nasal endoscopy and a Maxillofacial computed tomography scan. Results: Ten males and eight females with a mean age at the time of surgery of 20.05 ± 11.32 years, underwent surgery for choanal atresia. Fifteen subjects (83.33% had a bony while 3 (26.77% a mixed bony-membranous atretic plate. Two and sixteen cases suffered from bilateral and unilateral choanal atresia respectively. No intra- and/or early postoperative complications were observed. Between 2 and 3 months after surgery two cases (11.11% of partial restenosis were found. Only one of these presented a relapse of the nasal obstruction and was subsequently successfully repaired with a second endoscopic procedure. Conclusion: The surgical technique described follows the basic requirements of corrective surgery and allows good visualization, evaluation and treatment of the atretic plate and the posterior third of the septum, in order to create the new choanal opening. We believe that the use of a stent is not necessary, as recommended in case of other surgical techniques

  4. A novel technique for preventing skin pressure sores using a rubber tube during surgical treatment of mandibular condyle fractures.

    Science.gov (United States)

    Kawase-Koga, Yoko; Mori, Yoshiyuki; Hoshi, Kazuhito; Takato, Tsuyoshi

    2013-11-01

    Craniofacial surgery occasionally results in sores and necrosis of the facial skin because of pressure from surgical instruments. During surgical treatment of mandibular condylar process fractures, the main mandibular fragment is routinely retracted downward using a wire to achieve a satisfactory anatomic reduction. This procedure may injure the facial skin. This potential complication is easily overlooked by medical staff, but it is easily preventable. We herein describe a method of using a rubber tube to avoid causing pressure sores of the facial skin during surgical treatment of mandibular condylar process fractures.

  5. Treatment outcomes of the simple bone cyst: A comparative study of 2 surgical techniques using artificial bone substitutes.

    Science.gov (United States)

    Higuchi, Takashi; Yamamoto, Norio; Shirai, Toshiharu; Hayashi, Katsuhiro; Takeuchi, Akihiko; Kimura, Hiroaki; Miwa, Shinji; Abe, Kensaku; Taniguchi, Yuta; Tsuchiya, Hiroyuki

    2018-05-01

    Simple bone cysts (SBCs) are benign lesions of unknown etiology. Because of its high relapse rate, they occasionally need a long period of treatment and restriction of activities in children and adolescent. Although various treatment modalities with variable differing outcomes have been described in the literature, no consensus has been reached regarding the standard treatment. The purpose of this study was to evaluate the outcome of a minimally invasive technique that uses a ceramic hydroxyapatite cannulated pin (HA pin) for the treatment of SBCs.Between 1998 and 2015, we have treated 75 patients with SBCs either with continuous decompression by inserting HA pins after curettage and multiple drilling (group 1, n = 39 patients) or with calcium phosphate cement (CPC) filling after curettage (group 2, n = 36 patients). These patients were retrospectively analyzed for recurrence-free survival (RFS) and factors implicated in SBC recurrence.Seventy-five patients (50 man and 25 females) with a mean age of 17.5 ± 11.6 years and a histopathologically confirmed diagnosis of SBCs were included. The mean follow-up period was 33 ± 25.3 months. RFS were 88% at 1 year and 81% at 5 years. Residual or progressing cysts were observed in 12 patients after the surgery and 10 of them underwent additional surgery. Recurrence rate was significantly higher in patients under the age of 10 years (P = .01), in long bone cysts (P = .01), and in active phase cysts (P = .003) (log-rank test). Multivariate analysis results revealed that age less than 10 years was an independent risk factor of recurrence (P = .04). No significant difference in recurrence rate was observed between groups 1 and 2. However, the mean operating time was significantly shorter in group 1. (62.4 ± 25.6 vs 110.5 ± 48.4 minutes in group 2).Continuous decompression using HA pin is a less invasive surgical technique for the treatment of SBCs compared with CPC filling and has a

  6. Pedicle marrow signal intensity changes in the lumbar spine: a manifestation of facet degenerative joint disease

    International Nuclear Information System (INIS)

    Morrison, J.L.; Kaplan, P.A.; Dussault, R.G.; Anderson, M.W.

    2000-01-01

    Objective. Signal intensity changes in lumbar pedicles, similar to those described in vertebral body endplates adjacent to degenerated discs, have been described as an ancillary sign of spondylolysis on MRI. The purpose of this study was to determine whether pedicle marrow signal intensity changes also occur in association with facet degenerative joint disease.Design. Eighty-nine lumbar spine MRI examinations without spondylolysis were reviewed for marrow signal intensity changes in pedicles and vertebral bodies as well as for facet degenerative joint disease.Results. Five percent (46/890) of lumbar pedicles in 23 patients had marrow signal intensity changes. Ninety-one percent (42/46) of the abnormal pedicles had adjacent degenerative joint disease of the facets, while only 21% (189/890) of normal pedicles had adjacent facet degenerative joint disease (p<0.001). Eighty-nine percent (41/46) of the pedicles with marrow signal intensity changes had adjacent degenerative disc disease.Conclusions. Pedicle marrow signal intensity changes are not a specific sign of spondylolysis; they are commonly seen with adjacent facet degenerative joint disease in the absence of spondylolysis. Pedicle marrow signal intensity changes are probably a response to abnormal stresses related to abnormal motion or loading caused by the degenerative changes in the spinal segment. (orig.)

  7. Pedicle marrow signal intensity changes in the lumbar spine: a manifestation of facet degenerative joint disease

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, J.L.; Kaplan, P.A.; Dussault, R.G.; Anderson, M.W. [Dept. of Radiology, Univ. of Virginia Health System, Charlottesville, VA (United States)

    2000-12-01

    Objective. Signal intensity changes in lumbar pedicles, similar to those described in vertebral body endplates adjacent to degenerated discs, have been described as an ancillary sign of spondylolysis on MRI. The purpose of this study was to determine whether pedicle marrow signal intensity changes also occur in association with facet degenerative joint disease.Design. Eighty-nine lumbar spine MRI examinations without spondylolysis were reviewed for marrow signal intensity changes in pedicles and vertebral bodies as well as for facet degenerative joint disease.Results. Five percent (46/890) of lumbar pedicles in 23 patients had marrow signal intensity changes. Ninety-one percent (42/46) of the abnormal pedicles had adjacent degenerative joint disease of the facets, while only 21% (189/890) of normal pedicles had adjacent facet degenerative joint disease (p<0.001). Eighty-nine percent (41/46) of the pedicles with marrow signal intensity changes had adjacent degenerative disc disease.Conclusions. Pedicle marrow signal intensity changes are not a specific sign of spondylolysis; they are commonly seen with adjacent facet degenerative joint disease in the absence of spondylolysis. Pedicle marrow signal intensity changes are probably a response to abnormal stresses related to abnormal motion or loading caused by the degenerative changes in the spinal segment. (orig.)

  8. Pedicle measurement of the thoracolumbar spine: a cadaveric, radiographic, and CT scan study in Filipinos

    International Nuclear Information System (INIS)

    Molano, A.M.V.; Sison, A.B.; Fong, H.C.; Lim, N.T.; Sabile, K.

    1994-01-01

    With the popular usage of spinal pedicular screw fixation, it is essential to have a knowledge of the morphometry of the pedicles of the spine of particular populations. This study compared the direct pedicle measurements of ten cadavers in an institution, with their respective radiographic and computerized tomographic (CT) scan values, and also compared the effective pedicle diameter (EPD) with the conventional outer pedicle diameter (OPD) measurements. A compilation of pedicle values was also made in X-ray and CT scan plates of a Filipino population. A statistical analysis made on the 2,760 pedicle measurements taken from cadaveric T6-L5 vertebrae showed that direct measurements were significantly different from X-ray and CT scan values. The mean values of the EPD differed from those of the OPD, but not statistically significant. Comparison with previous foreign studies revealed significant differences in these pedicle dimensions. Pedicle measurements in a living Filipino population were found to be significantly different statistically between sexes. Accurate measurement of the pedicle diameters and lengths are indeed critical for the success of a spinal stabilization procedure using pedicular screws. (author). 8 refs.; 5 figs.; 1 tab

  9. A universal pedicle screw and V-rod system for lumbar isthmic spondylolysis: a retrospective analysis of 21 cases.

    Directory of Open Access Journals (Sweden)

    Xiong-sheng Chen

    Full Text Available To investigate the surgical outcome of a universal pedicle screw-V rod system and isthmic bone grafting for isthmic spondylolysis.Twenty-four patients with isthmic spondylolysis at L5 and grade 0-I spondylolisthesis (Meyerding classification received isthmic bone graft and stabilization using the universal pedicle screw-V rod system. Back pain was evaluated using the visual analog scale (VAS and time to bone healing, improvement in spondylolisthesis and intervertebral space height at L5/S1 and L4/L5 were assessed.Twenty-one patients were followed up for 24 months and included in the analysis. Back pain was markedly improved at 3 months postoperatively with a statistical difference in VAS scores compared with preoperative VAS scores (P<0.001. The VAS scores were 0 to 3 at 6 months postoperatively in all patients and no back pain was reported in all patients except 2 patients who complained of back pain after prolonged sitting. X-ray examination showed a bone graft healing time of 3 to 12 months. Grade I spondylolisthesis improved to grade 0 in 4 patients and no noticeable change was observed in the remaining 17 cases. The intervertebral space height at L5/S1 was statistically increased (P<0.05 while no statistically significant change was seen at L4/L5. There was no statistically significant difference in the ROM of the intervertebral disks of L5/S1 and L4/5 before and after surgery.The universal pedicle screw-V rod system and isthmic bone grafting directly repairs isthmic spondylolysis and reduces back pain, prevents anterior displacement of the diseased segment and maintains intervertebral space height, thus offering a promising alternative to current approaches for isthmic spondylolysis.

  10. Postoperative quality-of-life assessment in patients with spine metastases treated with long-segment pedicle-screw fixation.

    Science.gov (United States)

    Bernard, Florian; Lemée, Jean-Michel; Lucas, Olivier; Menei, Philippe

    2017-06-01

    OBJECTIVE In recent decades, progress in the medical management of cancer has been significant, resulting in considerable extension of survival for patients with metastatic disease. This has, in turn, led to increased attention to the optimal surgical management of bone lesions, including metastases to the spine. In addition, there has been a shift in focus toward improving quality of life and reducing hospital stay for these patients, and many minimally invasive techniques have been introduced with the aim of reducing the morbidity associated with more traditional open approaches. The goal of this study was to assess the efficacy of long-segment percutaneous pedicle screw stabilization for the treatment of instability associated with thoracolumbar spine metastases in neurologically intact patients. METHODS This study was a retrospective review of data from a prospective database. The authors analyzed cases in which long-segment percutaneous pedicle screw fixation was performed for the palliative treatment of thoracolumbar spinal instability due to spinal metastases in neurologically intact patients. All of the patients included in the study underwent surgery between January 2014 and May 2015 at the authors' institution. Postoperative radiation therapy was planned within 10 days following the stabilization in all cases. Clinical and radiological follow-up assessments were planned for 3 days, 3 weeks, 6 weeks, 3 months, 6 months, and 1 year after surgery. Outcome was assessed by means of standard postoperative evaluation and oncological and spinal quality of life measures (European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire Version 3.0 [EORTC QLQ-C30] and Oswestry Disability Index [ODI], respectively). Moreover, 5 patients were given an activity monitoring device for recording the distance walked daily; preoperative and postoperative daily distances were compared. RESULTS Data from 17 cases were analyzed. There were no

  11. The zygomatic implant perforated (ZIP) flap: a new technique for combined surgical reconstruction and rapid fixed dental rehabilitation following low-level maxillectomy.

    Science.gov (United States)

    Butterworth, C J; Rogers, S N

    2017-12-01

    This aim of this report is to describe the development and evolution of a new surgical technique for the immediate surgical reconstruction and rapid post-operative prosthodontic rehabilitation with a fixed dental prosthesis following low-level maxillectomy for malignant disease.The technique involves the use of a zygomatic oncology implant perforated micro-vascular soft tissue flap (ZIP flap) for the primary management of maxillary malignancy with surgical closure of the resultant maxillary defect and the installation of osseointegrated support for a zygomatic implant-supported maxillary fixed dental prosthesis.The use of this technique facilitates extremely rapid oral and dental rehabilitation within a few weeks of resective surgery, providing rapid return to function and restoring appearance following low-level maxillary resection, even in cases where radiotherapy is required as an adjuvant treatment post-operatively. The ZIP flap technique has been adopted as a standard procedure in the unit for the management of low-level maxillary malignancy, and this report provides a detailed step-by-step approach to treatment and discusses modifications developed over the treatment of an initial cohort of patients.

  12. Evaluation of the results from surgical treatment of fractures of the lateral extremity of the clavicle, using the double ligature technique

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    2015-04-01

    Full Text Available OBJECTIVE: To evaluate the incidence of consolidation in surgical treatment of fractures of the lateral extremity of the clavicle using the double subcoracoid ligature technique, with nonabsorbable No. 5 thread.METHODS: Between May 1993 and June 2013, the Shoulder and Elbow Group of our service surgically treated 116 patients (116 shoulders with fractures of the lateral extremity of the clavicle. Among these, we were able to reassess 65 cases. The surgical technique used consisted of double subcoracoid ligature with two nonabsorbable threads. In two patients classified as type III, we had to combine this technique with use of an interfragmentary screw for fixation of the intra-articular portion of the acromioclavicular joint.RESULTS: We achieved fracture consolidation in 90%. Fourteen cases (21% evolved with major complications: four cases of pseudarthrosis, five of adhesive capsulitis, two of delayed consolidation and three of loss of reduction. Two cases (3% evolved with minor complications of skin granuloma.CONCLUSION: The double ligature technique for fractures of the lateral extremity of the clavicle promotes the stabilization needed for consolidation to take place, without the need for synthesis using metal components. It avoids reoperation for the synthesis material to be removed. Moreover, it is a low-cost procedure with good reproducibility and preservation of the acromioclavicular joint.

  13. Comparison of revision strategies for failed C2-posterior cervical pedicle screws: a biomechanical study.

    Science.gov (United States)

    Mayer, Michael; Zenner, Juliane; Bogner, Robert; Hitzl, Wolfgang; Figl, Markus; von Keudell, Arvind; Stephan, Daniel; Penzkofer, Rainer; Augat, Peter; Korn, Gundobert; Resch, Herbert; Koller, Heiko

    2013-01-01

    With increasing usage within challenging biomechanical constructs, failures of C2 posterior cervical pedicle screws (C2-pCPSs) will occur. The purpose of the study was therefore to investigate the biomechanical characteristics of two revision techniques after the failure of C2-pCPSs. Twelve human C2 vertebrae were tested in vitro in a biomechanical study to compare two strategies for revision screws after failure of C2-pCPSs. C2 pedicles were instrumented using unicortical 3.5-mm CPS bilaterally (Synapse/Synthes, Switzerland). Insertion accuracy was verified by fluoroscopy. C2 vertebrae were potted and fixed in an electromechanical testing machine with the screw axis coaxial to the pullout direction. Pullout testing was conducted with load and displacement data taken continuously. The peak load to failure was measured in newtons (N) and is reported as the pullout resistance (POR). After pullout, two revision strategies were tested in each vertebra. In Group-1, revision was performed with 4.0-mm C2-pCPSs. In Group-2, revision was performed with C2-pedicle bone-plastic combined with the use of a 4-mm C2-pCPSs. For the statistical analysis, the POR between screws was compared using absolute values (N) and the POR of the revision techniques normalized to that of the primary procedures (%). The POR of primary 3.5-mm CPSs was 1,140.5 ± 539.6 N for Group-1 and 1,007.7 ± 362.5 N for Group-2; the difference was not significant. In the revision setting, the POR in Group-1 was 705.8 ± 449.1 N, representing a reduction of 38.1 ± 32.9 % compared with that of primary screw fixation. For Group-2, the POR was 875.3 ± 367.9 N, representing a reduction of 13.1 ± 23.4 %. A statistical analysis showed a significantly higher POR for Group-2 compared with Group-1 (p = 0.02). Although the statistics showed a significantly reduced POR for both revision strategies compared with primary fixation (p plastic, the POR can be significantly increased compared with the use of only an

  14. Postirradiation lesions of the brachial plexus. Results of surgical treatment

    International Nuclear Information System (INIS)

    LeQuang, C.

    1989-01-01

    In a series of 103 cases of postirradiation lesions of the brachial plexus operated on between 1978 and 1986--of which 60 patients have been reviewed with a follow up from 2 to 9 years--the surgical results are analyzed according to an anatomic classification, a clinical classification, and the surgical procedures. We conclude that the radiation plexitis should be treated surgically and at the earliest possible time after the onset of paresthesias. Also, the surgical procedure which gives the best results is neurolysis with pedicled omentoplasty

  15. Modified frontolateral partial laryngectomy operation: combined muscle-pedicle hyoid bone and thyrohyoid membrane flap in laryngeal reconstruction

    International Nuclear Information System (INIS)

    Ouyang, Dian; Liu, Tian-Run; Chen, Yan-Feng; Wang, Jian

    2013-01-01

    Laryngeal reconstruction is needed to preserve laryngeal function in patients who have undergone extensive vertical or frontal partial laryngectomy. However, the procedure remains a difficult challenge. Several reconstruction techniques have been described, but these techniques pose risks of complications such as laryngeal stenosis. This study aimed to evaluate the postoperative course and functional outcomes of a new technique that combined a muscle-pedicle hyoid bone and a thyrohyoid flap during laryngeal reconstruction after tumor resection. Four patients underwent extensive vertical partial or frontal partial laryngectomy for cancer. After tumor resection, laryngeal reconstruction was performed using the proposed technique. Postoperative recovery time, complications, and oncologic results were evaluated. The four patients were successfully treated with the proposed technique. No dyspnea, dysphagia, or death occurred during the postoperative course. Decannulation was performed after a median of 3 days. The average postoperative hospital stay was 7 days. Short-term postoperative functional recovery was normal. No laryngeal stenosis or tumor recurrence was observed in any of the four patients after a follow-up period of more than 24 months. The combination of the muscle-pedicle hyoid bone and the thyrohyoid flap is a reliable procedure for laryngeal reconstruction after extensive vertical partial or frontal partial laryngectomy

  16. Pedicled Instep Flap and Tibial Nerve Reconstruction in a Cynomolgus Monkey [Macaca fascicularis

    Directory of Open Access Journals (Sweden)

    Ruth Weiss

    2016-01-01

    Full Text Available A male cynomolgus monkey experienced extensive soft tissue trauma to the right caudal calf area. Some weeks after complete healing of the original wounds, the monkey developed a chronic pressure sore on plantar surface of the heel of its right foot. A loss of sensitivity in the sole of the foot was hypothesized. The skin defect was closed by a medial sensate pedicled instep flap followed by counter transplantation of a full thickness graft from the interdigital webspace. The integrity of the tibial nerve was revised and reconstructed by means of the turnover flap technique. Both procedures were successful. This is an uncommon case in an exotic veterinary patient as it demonstrates a reconstructive skin flap procedure for the treatment of a chronic, denervated wound in combination with the successful reconstruction of 2.5 cm gap in the tibial nerve.

  17. Rapid orthodontic treatment after the ridge-splitting technique--a combined surgical-orthodontic approach for implant site development: case report.

    Science.gov (United States)

    Amato, Francesco; Mirabella, A Davide; Borlizzi, Diego

    2012-08-01

    This article presents a clinical case of bilateral partial edentulism in the posterior mandible with severe horizontal and moderate vertical bone atrophy. A new technique using rapid orthodontics after ridge splitting is presented. The split-crest technique was carried out using piezosurgical instruments in the first molar and second premolar areas to widen the bone crest and open a channel for tooth movement. Immediately after, orthodontic appliances were used to move the first premolars distally and the second molars mesially into the surgical site. The rationale was to facilitate and accelerate orthodontic movement of the teeth, which is otherwise difficult in a cortical knife-edged ridge. The bone defect was filled with the alveolar bone of the adjacent teeth that were moved into the surgically opened path. Adequate bone volume for implant placement was generated in the first premolar area. Implants were then inserted, and the patient was rehabilitated.

  18. [Surgical technique and clinical results of total knee arthroplasty in treating endstage gonarthrosis combined with valgus knee deformity].

    Science.gov (United States)

    Wang, Xingshan; Weng, Xisheng; Lin, Jin; Jin, Jin; Qian, Wenwei

    2012-05-01

    To investigate the surgical technique and the clinical results of total knee arthroplasty (TKA) in treating end-stage gonarthrosis combined with valgus knee deformity. Between November 1998 and October 2010, 64 patients (72 knees) with end-stage gonarthrosis combined with valgus knee deformity underwent TKA by a medial parapatellar approach. Of the 64 patients, 18 were male and 46 were female with an average age of 62.5 years (range, 23-82 years), including 44 cases (49 knees) of osteoarthritis, 17 cases (20 knees) of rheumatoid arthritis, 2 cases (2 knees) of haemophilic arthritis, and 1 case (1 knee) of post-traumatic arthritis. Bilateral knees were involved in 8 cases, and single knee in 56 cases. The flexion and extension range of motion (ROM) of the knee joint was (82.2 +/- 28.7) degrees; the femur-tibia angle (FTA) was (18.0 +/- 5.8) degrees; according to Knee Society Score (KSS) criterion, the preoperative clinical score was 31.2 +/- 10.1 and functional score was 37.3 +/- 9.0. According to Krackow's classification, there were 65 knees of type I and 7 knees of type II. By medial parapatellar approach, conventional osteotomy and Ranawat soft tissue release were performed in all cases. Prosthesis of preserved posterior cruciate ligament were used in 7 cases (7 knees), posterior stabilize prosthesis in 54 cases (60 knees), constrained prosthesis in 4 cases (5 knees). Incisions healed by first intention in all cases. Peroneal nerve palsy occurred in 1 patient with haemophilic arthritis, severe valgus deformity (FTA was 41 degrees), and flexion contracture (20 degrees), which was cured after 1 year of conservative treatment. Revison surgery was performed in 1 case of deep infection at 2 years after surgery. All the patients were followed up 4.9 years on average (range, 1-13 years). At last follow-up, the FTA was (7.0 +/- 2.5) degrees, showing significant difference when compared with preoperative value (t = 15.502, P = 0.000). The KSS clinical score was 83.0 +/- 6

  19. Robot assisted navigated drilling for percutaneous pedicle screw placement: A preliminary animal study

    Directory of Open Access Journals (Sweden)

    Hongwei Wang

    2015-01-01

    Conclusions: The preliminary study supports the view that computer assisted pedicle screw fixation using spinal robot is feasible and the robot can decrease the intraoperative fluoroscopy time during the minimally invasive pedicle screw fixation surgery. As spine robotic surgery is still in its infancy, further research in this field is worthwhile especially the accuracy of spine robot system should be improved.

  20. Posterior intravaginal slingplasty with preservation of the uterus: a modified surgical technique in a young myelomeningocele patient

    NARCIS (Netherlands)

    Verguts, Jasper; Roovers, Jan-Paul; de Ridder, Dirk; Coremans, Georges; Deprest, Jan

    2007-01-01

    We report a case of uterine prolapse in a young woman, treated by posterior intravaginal slingplasty with preservation of the uterus as a feasible and safe surgical procedure. Posterior intravaginal slingplasty is commonly used to correct vaginal vault prolapse, but may be a valuable alternative to

  1. Surgical Treatment of Renal Cell Carcinoma with Inferior Vena Cava Thrombus: Using Liver Mobilization Technique to Avoid Cardiopulmonary Bypass

    Directory of Open Access Journals (Sweden)

    Tawatchai Taweemonkongsap

    2008-04-01

    CONCLUSION: These results support the aggressive surgical removal of RCC with IVC thrombus as the initial treatment. Most of the thrombi can be approached and safely controlled by a transabdominal approach without any form of bypass. Tumour thrombus removal provides a high survival chance and offers improvement in quality of life.

  2. The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model.

    NARCIS (Netherlands)

    Shalabi, M.M.; Wolke, J.G.C.; Jansen, J.A.

    2006-01-01

    OBJECTIVES: The aim of the present study was to determine the relationship between implant surface parameters, surgical approach and initial implant fixation. MATERIAL AND METHODS: Sixty tapered, conical, screw-shaped implants with machined or etched surface topography were implanted into the

  3. The value of three-dimensional photogrammetry in isolated sagittal synostosis: Impact of age and surgical technique on intracranial volume and cephalic index─a retrospective cohort study.

    Science.gov (United States)

    Mertens, Christian; Wessel, Eline; Berger, Moritz; Ristow, Oliver; Hoffmann, Jürgen; Kansy, Katinka; Freudlsperger, Christian; Bächli, Heidrun; Engel, Michael

    2017-12-01

    The aim of this study was to compare the outcome of intracranial volume (ICV) and cephalic index (CI) between two different techniques for surgical therapy of sagittal synostosis. Between 2011 and 2015, all patients scheduled for surgical therapy of sagittal synostosis were consecutively enrolled. All patients younger than 6 months underwent early extended strip craniectomy (ESC group), and patients older than 6 months underwent late modified pi-procedure (MPP group). To measure ICV and CI, data acquisition was performed via three-dimensional photogrammetry, 1 day before (T0) and between 10 and 12 weeks after surgery (T1). Results were compared with an age-matched reference group of healthy children. Perioperative parameters, as duration of surgery and the amount of blood loss of both surgical procedures were analyzed. A total of 85 patients were enrolled. Of the patients, 48 underwent an extended strip craniotomy with parietal osteotomies and biparietal widening and 37 patients underwent a late modified pi-procedure. There was no significant difference between the ESC group and the MPP group regarding the efficacy of improving CI (p > 0.05). Both techniques were able to normalize CI and to improve head shape. ICV was normal compared to age-matched norm-groups with both techniques, pre- and postoperatively. However, duration of the surgical procedure and calculated blood loss were significantly lower in the ESC group (p photogrammetry is a valid method to objectively evaluate patients before and after surgery without exposing pediatric patients to ionizing radiation. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Combined anterior C2-C3 fusion and C2 pedicle screw fixation for the treatment of unstable hangman's fracture: a contrast to anterior approach only.

    Science.gov (United States)

    Xie, Ning; Khoo, Larry T; Yuan, Wen; Ye, Xiao-Jian; Chen, De-Yu; Xiao, Jian-Ru; Ni, Bin

    2010-03-15

    A retrospective clinical study was used to evaluate the effect of a new surgical treatment of the hangman's fractures. To determine the treatment efficacy of combined anterior C2-C3 reduction and fusion and posterior compressive C2 pedicle screw fixation for the management of unstable hangman's fractures. The classification of hangman's fractures as proposed by Levine-Edwards was used to classify and guide the treatment of these injuries. Most of these fractures respond to a variety of conservative therapies, but recently, earlier surgery has been increasingly advocated by authors from several countries for the rapid stabilization of these fractures. If surgery is indicated, an anterior approach using a C2-C3 reduction and fusion is preferred usually. Another well-accepted surgical method is the direct transpedicular osteosynthesis by the dorsal approach. However, there was rare report of the combined use of these 2 techniques. A group of 45 surgical patients were all diagnosed with radiograph, magnetic resonance imaging (MRI), and 3D CT scans. Initial and final radiographs were measured for anterior translation and angulation of the C2-C3 complex. Initial external skull traction with extension was used in all patients after admission to reduce the fracture. Then an anterior C2-C3 discectomy followed by an interbody fusion and locking plate fixation was performed. Intraoperative reduction was confirmed by fluoroscopic control. About 29 patients therefore received anterior surgeries only since satisfactory reduction was achieved during the procedure. For the 16 patients who had persistent large residual gaps after the anterior procedure, additional same stage posterior C2 compressive pedicle screws were placed. Clinical and radiologic comparisons were performed in these 2 groups. The follow-up ranged from 24 to 54 months, with an average 33.6 months. There was radiographic evidence of continuity of the fracture and the bone graft seen at 4.7 months on average. Neck

  5. Comparison between lamellar keratoplasties produced by conjunctival pedicle and free corneal autografts. Experimental study in the dog (Canis familiaris - LINNAEUS, 1758

    Directory of Open Access Journals (Sweden)

    José Luiz Laus

    1996-03-01

    Full Text Available A comparative study of conjunctival pedicle and corneal autografts, for experimental healing of superficial keratectomies in dogs (Canis familiaris was performed. It was carried out by using 24 animals, and the technical procedures were analysed according to clinical, histologic and scanning electron microscopy parameters, in early and late postoperative periods. The obtained results are believed to represent feasible methods of proteresis, applied to the healing ophthalmic surgery. There were few, irrelevant differences between the two tested techniques.

  6. Probing and Tapping: Are We Inserting Pedicle Screws Correctly?

    Science.gov (United States)

    Prasad, Vishal; Mesfin, Addisu; Lee, Robert; Reigrut, Julie; Schmidt, John

    2016-11-01

    Although there are a significant number of research publications on the topic of bone morphology and the strength of bone, the clinical significance of a failed pedicle screw is often revision surgery and the potential for further postoperative complications; especially in elderly patients with osteoporotic bone. The purpose of this report is to quantify the mechanical strength of the foam-screw interface by assessing probe/pilot hole diameter and tap sizes using statistically relevant sample sizes under highly controlled test conditions. The study consisted of two experiments and used up to three different densities of reference-grade polyurethane foam (ASTM 1839), including 0.16, 0.24, and 0.32 g/cm 3 . All screws and rods were provided by K2M Inc. and screws were inserted to a depth of 25 mm. A series of pilot holes, 1.5, 2.2, 2.7, 3.2, 3.7, 4.2, 5.0, and 6.0 mm in diameter were drilled through the entire depth of the material. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 720). A 3.0-mm pilot hole was drilled and tapped with: no tap, 3.5-, 4.5-, 5.5-, and 6.5-mm taps. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 300). The size of the probe/pilot hole had a nonlinear, parabolic effect on pullout strength. This shape suggests an optimum-sized probe hole for a given size pedicle screw. Too large or too small of a probe hole causes a rapid falloff in pullout strength. The tap data demonstrated that not tapping and undertapping by two or three sizes did not significantly alter the pullout strength of the screws. The data showed an exponential falloff of pullout strength when as tap size increased to the diameter of the screw. In the current study, the data show that an ideal pilot hole size half the diameter of the screw is a starting point. Also, that if tapping was necessary, to use a tap two sizes smaller than the screw being implanted. A similar optimum pilot hole or tap size may be

  7. Are We Underestimating the Significance of Pedicle Screw Misplacement?

    Science.gov (United States)

    Sarwahi, Vishal; Wendolowski, Stephen F; Gecelter, Rachel C; Amaral, Terry; Lo, Yungtai; Wollowick, Adam L; Thornhill, Beverly

    2016-05-01

    A retrospective review of charts, x-rays (XRs) and computed tomography (CT) scans was performed. To evaluate the accuracy of pedicle screw placement using a novel classification system to determine potentially significant screw misplacement. The accuracy rate of pedicle screw (PS) placement varies from 85% to 95% in the literature. This demonstrates technical ability but does not represent the impact of screw misplacement on individual patients. This study quantifies the rate of screw misplacement on a per-patient basis to highlight its effect on potential morbidity. A retrospective review of charts, XRs and low-dose CT scans of 127 patients who underwent spinal fusion with pedicle screws for spinal deformity was performed. Screws were divided into four categories: screws at risk (SAR), indeterminate misplacements (IMP), benign misplacements (BMP), accurately placed (AP). A total of 2724 screws were placed in 127 patients. A total of 2396 screws were placed accurately (87.96%). A total of 247 screws (9.07%) were BMP, 52 (1.91%) were IMP, and 29 (1.06%) were considered SAR. Per-patient analysis showed 23 (18.11%) of patients had all screws AP. Thirty-five (27.56%) had IMP and 18 (14.17%) had SAR. Risk factor analysis showed smaller Cobb angles increased likelihood of all screws being AP. Sub-analysis of adolescent idiopathic scoliotic patients showed no curve or patient characteristic that correlated with IMP or SAR. Over 40% of patients had screws with either some/major concern. Overall reported screw misplacement is low, but it does not reflect the potential impact on patient morbidity. Per-patient analysis reveals more concerning numbers toward screw misplacement. With increasing pedicle screw usage, the number of patients with misplaced screws will likely increase proportionally. Better strategies need to be devised for evaluation of screw placement, including establishment of a national database of deformity surgery, use of intra-operative image guidance, and

  8. EFFECT OF PILOT HOLE TAPPING ON PULLOUT STRENGTH AND INSERTION TORQUE OF DUAL CORE PEDICLE SCREWS.

    Science.gov (United States)

    Rosa, Rodrigo César; Silva, Patrícia; Falcai, Maurício José; Shimano, Antônio Carlos; Defino, Helton Luiz Aparecido

    2010-01-01

    To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity of 10 Nm, which was considered to be the highest torque value. The pilot holes were prepared using a probe of external diameter 3.8 mm and tapping of the same dimensions and thread characteristics as the screw. Decreased insertion torque and pullout resistance were observed in the group with prior tapping of the pilot hole. Pilot hole tapping reduced the insertion torque and pullout resistance of pedicle screws with a conical core that had been inserted into the pedicle of the fifth lumbar vertebra of calves.

  9. Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws

    Energy Technology Data Exchange (ETDEWEB)

    Hudyana, Hendrah; Maes, Alex [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Hospital Leuven, Department of Morphology and Medical Imaging, Leuven (Belgium); Vandenberghe, Thierry; Fidlers, Luc [AZ Groeninge, Department of Neurosurgery, Kortrijk (Belgium); Sathekge, Mike [University of Pretoria, Department of Nuclear Medicine, Pretoria (South Africa); Nicolai, Daniel [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2016-02-15

    The aim of this retrospective study was to evaluate the accuracy of bone SPECT (single photon emission computed tomography)/CT (computed tomography) in diagnosing loosening of fixation material in patients with recurrent or persistent back pain that underwent lumbar arthrodesis with pedicle screws using surgery and clinical follow-up as gold standard A total of 48 patients (median age 49 years, range 21-81 years; 17 men) who had undergone lumbar spinal arthrodesis were included in this retrospective analysis. SPECT/CT results were compared to the gold standard of surgical evaluation or clinical follow-up. Positive SPECT/CT results were considered true positives if findings were confirmed by surgery or if clinical and other examinations were completely consistent with the positive SPECT/CT finding. They were considered false positives if surgical evaluation did not find any loose pedicle screws or if symptoms subsided with non-surgical therapy. Negative SPECT/CT scans were considered true negatives if symptoms either improved without surgical intervention or remained stable over a minimum follow-up period of 6 months. Negative SPECT/CT scans were determined to be false negatives if surgery was still required and loosening of material was found. The median length of time from primary surgery to bone SPECT/CT referral was 29.5 months (range 12-192 months). Median follow-up was 18 months (range 6-57) for subjects who did not undergo surgery. Thirteen of the 48 patients were found to be positive for loosening on bone SPECT/CT. Surgical evaluation (8 patients) and clinical follow-up (5 patients) showed that bone SPECT/CT correctly predicted loosening in 9 of 13 patients, while it falsely diagnosed loosening in 4 patients. Of 35 negative bone SPECT/CT scans, 12 were surgically confirmed. In 18 patients, bone SPECT/CT revealed lesions that could provide an alternative explanation for the symptoms of pain (active facet degeneration in 14 patients, and disc and sacroiliac

  10. Localized Pigmented Villonodular Synovitis of the Hip: Sudden-Onset Pain Caused by Torsion of the Tumor Pedicle

    Directory of Open Access Journals (Sweden)

    Kiyokazu Fukui

    2013-01-01

    Full Text Available Pigmented villonodular synovitis is a rare, benign, but potentially locally aggressive disease that should be considered in younger patients who present with monoarticular joint symptoms and pathology. We present the case of a 33-year-old woman with a mass arising from her right hip joint that was examined using a multimodal radiological approach. Because her clinical presentation mimicked that of synovial osteochondromatosis of the hip, surgical dislocation was performed. Histopathological examination of the resected specimen confirmed the diagnosis of localized pigmented villonodular synovitis, with the mass consisting of proliferation of fibrohistiocytic cells, abundant hemosiderin, foamy histiocytes, and occasional giant cells. Because of the presence of tumor necrosis, we hypothesize that torsion of the tumor pedicle was the cause of acute presentation.

  11. Making mock-FNA smears from fresh surgical pathology specimens to improve smear preparation technique and to create cytohistological correlation series.

    Directory of Open Access Journals (Sweden)

    Tibor Mezei

    Full Text Available Fine needle aspiration (FNA cytology is a well-established diagnostic method based on the microscopic interpretation of often scant cytological material; therefore, experience, good technique and smear quality are equally important in obtaining satisfactory results.We studied the use of fresh surgical pathology specimens for making so-called mock-FNA smears with the potential of cytohistological correlation. Additionally, we studied how this process aids the improvement of preparation technique and smear quality.Cytological aspirates from 32 fresh biopsy specimens from various sites: lung (20, lymph nodes (6, and breast (6 were obtained, all with a clinical diagnosis of tumor. Aspiration was performed from grossly palpable tumors. 25 G needle and Cameco-type syringe holder was used with minimal or no suction.Unfixed surgical specimens provided sufficient cytological material that resulted in good quality smears. After standard processing of specimens into microscopic sections from paraffin embedded tissues, cytohistological case-series were created. No significant alteration was reported in tissue architecture on hematoxylin-eosin stained sections after the aspiration procedure. A gradual, but steady improvement was observed in smear quality just after a few preparations.Our study proved that surgical specimens may be used as a source of cytological material to create cytohistological correlation studies and also to improve FNA cytology skills. The use of very fine gauge needle (25 G, 0,6 mm diameter during the sampling process does not alter tissue architecture therefore the final histopathological diagnosis is not compromised. We conclude that by using fresh surgical specimens useful cytohistological collections can be created both as a teaching resource and as improving experience.

  12. A Novel Pedicle Screw with Mobile Connection: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Yasuaki Tokuhashi

    2014-01-01

    Full Text Available To prevent adjacent disc problems after spinal fusion, a pedicle screw with a mobile junction between the head and threaded shaft was newly developed. The threaded shaft of the screw has 10 degrees mobility in all directions, but its structure is to prevent abnormal translation and tilting. This screw was evaluated as follows: (1 endurance test: 106 times rotational stress was applied; (2 biological reactions: novel screws with a mobile head and conventional screws with a fixed head were inserted into the bilateral pedicles of the L3, L4, and L5 in two mini pigs with combination. Eight months after surgery, vertebral units with the screw rod constructs were collected. After CT scan, the soft and bony tissues around the screws were examined grossly and histologically. As a result, none of the screws broke during the endurance test stressing. The mean amount of abrasion wear was 0.0338 g. In the resected mini pig section, though zygapophyseal joints between fixed-head screws showed bony union, the amount of callus in the zygapophyseal joints connected with mobile-head screws was small, and joint space was confirmed by CT. No metalloses were noted around any of the screws. Novel screws were suggested to be highly durable and histologically safe.

  13. Lower abdominal wall reconstructions with pedicled rectus femoris flaps

    International Nuclear Information System (INIS)

    Arashiro, Ken; Nishizeki, Osamu; Ishida, Kunihiro

    2003-01-01

    During the past 10 years, seven pedicled rectus femoris muscle or musculocutaneous flaps were used to repair lower abdominal defects; three recalcitrant incisional hernias with previous radiotherapy, two long-standing wound infections after synthetic mesh reconstruction, one posttraumatic wall defect and one metastatic tumor. There were two flap complications, one skin paddle necrosis and one wound infection. There was no significant disability of the donor limb encountered. During the two-year and seven month average follow-up, there was no recurrence of the problems except for one minor fascial dehiscence in the patient with metastatic abdominal wall tumor. Easy approach, rapid harvest, relatively large and reliable overlying fascia lata, a single dominant neurovascular pedicle, easy primary closure of the donor site, and minimal donor site morbidity all make the rectus femoris flap a good alternative flap for lower abdominal wall reconstruction. It is especially useful in a condition where synthetic mesh would be unsuitable for defects with infection or recurrent incisional hernia after radiotherapy. (author)

  14. Surgical Assisting

    Science.gov (United States)

    ... instruction, including: Microbiology Pathophysiology Pharmacology Anatomy and physiology Medical terminology Curriculum . Course content includes: Advanced surgical anatomy Surgical microbiology Surgical pharmacology Anesthesia methods and agents Bioscience Ethical ...

  15. Inferior Pedicle Reduction Mammoplasty with or without Tourniquet: A Comparative Study.

    Science.gov (United States)

    Demir, Canser Yilmaz; Sultanoglu, Yılmaz; Kocak, Omer Faruk; Ersoz, Muhammet Eren

    2017-10-01

    To compare the perioperative findings of inferior pedicle reduction mammoplasty (IPRM) performed with or without a tourniquet. This study was carried out in the plastic and reconstructive surgery department at a tertiary care center on a total of 42 consecutive women scheduled for IPRM. Patients in Group I (n = 21) underwent surgery using a tourniquet, whereas patients in Group II (n = 21) were operated on without a tourniquet. Levels of hemoglobin (Hb), hematocrit (Hct), Hct/Hb ratio, and platelet counts were noted preoperatively and on postoperative 24th and 48th h. Numbers of surgical pads and gauze sponges completely used and dripping with blood were recorded. Duration of operation, the amount of breast tissue excised on both sides, and fluid collected in hemovac drains on 48th h after operation were documented. In Group I, the operative time was significantly shorter (p usage is practical and safe, and it may also improve the cost-effectiveness of the procedure. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  16. Drenaje suplementario del sistema venoso superficial en colgajos pediculados Supplementary drainage of superficial venous system in pedicled flaps

    Directory of Open Access Journals (Sweden)

    A. Fernández García

    2012-06-01

    Full Text Available Los colgajos pediculados pueden sufrir edema y congestión debido a que su drenaje a trevés del sistema venoso superfical es imposible y el flujo hacia el sistema profundo a nivel del pedículo es precario. Esta situación suele evolucionar hacia la necrosis parcial o la pérdida total del colgajo en pocas horas. La apertura del sistema venoso superficial permite el drenaje adecuado de los tejidos transferidos y evita estas complicaciones. Este artículo analiza el papel de las anastomosis microquirúrgicas en el sistema venoso superficial de los colgajos pediculados. Esta técnica permite comunicar el sistema venoso superfical de los tejidos transferidos con el sistema venoso superficial del territorio que rodea al defecto. Presentamos los resultados obtenidos con esta técnica en colgajos de perforante en hélice, colgajos miocutáneos, colgajos neurocutáneos y colgajos fasciograsos volteados.The pedicled flaps can suffer edema and congestion due to the impossibility of drainage toward the superficial venous system and the precarious flow via the deep system at the level of the pedicle. The evolution of this situation is usually partial necrosis or total loss of the flap in a few hours. The opening of the venous superficial system achieves an appropriate drainage of the transfered tissues and avoids these complications. In this article we analyze the role of the microsurgical anastomosis at the level of the superficial venous system of pedicled flaps. This technique allows to communicate the superficial venous system of the transfered tissues with the superficial venous system of the territory around the defect. We report the results with this method in propeller perforator flaps, miocutaneous flaps, neurocutaneous flaps and adipofascial turn over flaps.

  17. A Comparative Study of Clear Corneal Phacoemulsification with Rigid IOL Versus SICS; the Preferred Surgical Technique in Low Socio-economic group Patients of Rural Areas.

    Science.gov (United States)

    Devendra, Jaya; Agarwal, Smita; Singh, Pankaj Kumar

    2014-11-01

    Low socio-economic group patients from rural areas often opt for free cataract surgeries offered by charitable organisations. SICS continues to be a time tested technique for cataract removal in such patients. In recent times, camp patients are sometimes treated by clear corneal phacoemulsification with implantation of a rigid IOL, which being more cost effective is often provided for camp patients. This study was undertaken to find out which surgical technique yielded better outcomes and was more suited for high volume camp surgery. To find the better surgical option- phacoemulsification with rigid IOL or SICS, in poor patients from rural areas. A prospective randomised controlled trial of cataract patients operated by two different techniques. One hundred and twelve eyes were selected and were randomly allocated into two groups of 56 eyes each. At completion of the study, data was analysed for 52 eyes operated by clear corneal phacoemulsification and implantation of a rigid IOL, and 56 eyes operated by SICS. Unpaired t-test was used to calculate the p- value. The results were evaluated on the following criteria. The mean post-operative astigmatism at the end of four weeks - was significantly higher in phacoemulsification group as compared to SICS group The BCVA (best corrected visual acuity) at the end of four weeks - was comparable in both groups. Subjective complaints and/ or complications: In phaco group two patients required sutures and seven had striate keratitis , while none in SICS group. Complaint of irritation was similar in both groups. Surgical time- was less for SICS group as compared to phaco group. SICS by virtue of being a faster surgery with more secure wound and significantly less astigmatism is a better option in camp patients from rural areas as compared to phacoemulsification with rigid IOL.

  18. Abortion - surgical

    Science.gov (United States)

    Suction curettage; Surgical abortion; Elective abortion - surgical; Therapeutic abortion - surgical ... Surgical abortion involves dilating the opening to the uterus (cervix) and placing a small suction tube into the uterus. ...

  19. A new surgical technique for traumatic dislocation of posterior tibial tendon with avulsion fracture of medial malleolus.

    Science.gov (United States)

    Jeong, Soon-Taek; Hwang, Sun-Chul; Kim, Dong-Hee; Nam, Dae-Cheol

    2015-01-01

    We introduce a case of traumatic dislocation of the posterior tibial tendon with avulsion fracture of the medial malleolus in a 52-year-old female patient who was treated surgically with periosteal flap and suture anchor fixation. Based in the posteromedial ridge of the distal tibia, a quadrilateral periosteal flap was created and folded over the tendon, followed by fixation on the lateral aspect of the groove by use of multiple suture anchors. Clinical and radiological findings 25 months postoperatively showed well-preserved function of the ankle joint with stable tendon gliding.

  20. The initial experience of introducing the Onstep technique for inguinal hernia repair in a general surgical department

    DEFF Research Database (Denmark)

    Andresen, K; Burcharth, Jakob Hornstrup Frølunde; Rosenberg, J

    2015-01-01

    BACKGROUND AND AIMS: A new technique for the repair of inguinal hernia, called Onstep, has been described. This technique places the mesh in the preperitoneal space medially and between the internal and external oblique muscles laterally. The Onstep technique has not yet been described outside...... repair. Inguinal Pain Questionnaire results: 95.5% reported no pain or pain that was easily ignored. CONCLUSIONS: It seems from this study that the Onstep technique is a safe method for inguinal hernia repair regarding perioperative and postoperative complications. The postoperative pain seems...

  1. All Internal Segmental Bone Transport and Optional Lengthening With a Newly Developed Universal Cylinder-Kombi-Tube Module for Motorized Nails-Description of a Surgical Technique.

    Science.gov (United States)

    Krettek, Christian; El Naga, Ashraf

    2017-10-01

    Segmental transport is an effective method of treatment for segmental defects, but the need for external fixation during the transport phase is a disadvantage. To avoid external fixation, we have developed a Cylinder-Kombi-Tube Segmental Transport (CKTST) module for combination with a commercially available motorized lengthening nail. This CKTST module allows for an all-internal segmental bone transport and also allows for optional lengthening if needed. The concept and surgical technique of CKTST are described and illustrated with a clinical case.

  2. Treatment of lithic tumors of the distal ending of the radius: Results of two surgical techniques in a series of cases

    International Nuclear Information System (INIS)

    Escandon, Santiago; Soto, Camilo; Pulido, Edgar

    2003-01-01

    The distal ending of the radius can bear several tumors with different degrees of aggressiveness that depend on the extension of the tumor. Their treatment varies according to the aggressiveness it and can include curettage only or may require more extensive surgical procedures including, in some cases reconstructive surgery. The present study describes two surgical reconstructive techniques and their results in a series of cases. Five patients underwent radio-carpal, and three Ulnar-carpal arthrodesis with non-vascularized autologous bone graft from the iliac crest. Pathology diagnosis included: six giant cell tumors, one Ewing's sarcoma, and one chondroblastoma. There were five males and three females, with an average age of 34.6 years (rank: 17-52). All the patients underwent wide surgical resection of the tumor, and only the patient with the Ewing's sarcoma received additionally adjuvant chemotherapy and radiotherapy. Five patients had compromise of the surrounding soft tissues. Two had limitation of movement of the fingers, and one hypoesthesia. One patient with ulnar arthrodesis had a fracture of the cubitus, at the proximal ending of the plate, secondary to trauma. AII patients have been followed for an average time of 12.8 months (rank: 0.5-72). There have been no episodes of infection. Neither non-union of the osteotomies, nor failures of fixation or recurrences were observed

  3. The short-term effect of surgical treatment for stress urinary incontinence using sub urethral support techniques on sexual function

    Directory of Open Access Journals (Sweden)

    Antonio C. Pinto

    2007-12-01

    Full Text Available OBJECTIVES: To evaluate the impact of surgical treatment of stress urinary incontinence on the sexual function of women and to identify whether such treatment can improve their sexual function and overall quality of life. MATERIALS AND METHODS: 64 heterosexual women with such indication were studied using the Female Sexual Function Index (FSFI questionnaire, modified by introducing one question to evaluate the impact of urine loss. This was applied preoperatively and six months after surgery. RESULT: Among these 64 patients, 60.94% had regular sexual activity, while 39.06% did not. Among sexually active patients, 59% had urine loss during sexual intercourse and, of these, 87% had urine losses in half or more of sexual relations. There were no statistically significant differences in assessments of desire, arousal, lubrication, orgasm, satisfaction and pain, or in totaling the scores, between the preoperative period and six months after surgical treatment. However, the scores for urine losses during sexual intercourse were significantly better after the operation. CONCLUSIONS: Analysis of the results allowed the following conclusions to be reached: Urine lost during sexual activity was frequent among patients with stress urinary incontinence. Suburethral support surgery did not jeopardize sexual activity. Patients cured of stress urinary incontinence did not present improvement in sexual function.

  4. Costs analysis of surgical treatment of stress urinary incontinence in a brazilian public hospital, comparing burch and synthetic sling techniques.

    Science.gov (United States)

    Limberger, Leo Francisco; Faria, Fernanda Pacheco; Campos, Luciana Silveira; Anzolch, Karin Marise Jaeger; Fornari, Alexandre

    2018-01-01

    Surgical treatment of urinary incontinence progressed significantly with the introduction of synthetic slings. However, in some public Brazilian hospitals, the costs of these materials prevent their routine use. To compare the costs of ambulatory synthetic sling surgery with an historical series of patients submitted to Burch surgery in a Brazilian public hospital. Twenty nine incontinent patients were selected to synthetic sling surgery. Demographic data were prospectively collected and also the costs of the procedure, including drugs and materials, use of surgical and recovery wards, medical staff and hospitalization. These data were compared to the costs of 29 Burch surgeries performed before the introduction of synthetic slings. Demographic data were similar, although median age was lower in the group submitted to Burch surgery (46.3±8.6 versus 56.2±11.3 (pCost was significantly lower in patients submitted to sling in all items, except for time spent in recovery ward. Total value of 29 Burch surgeries was R$ 217.766.12, and of R$ 68.049.92 of 29 patients submitted to sling surgery (pcost of the synthetic sling was considered. Copyright® by the International Brazilian Journal of Urology.

  5. Recovery of shoulder strength and proprioception after open surgery for recurrent anterior instability: a comparison of two surgical techniques.

    Science.gov (United States)

    Rokito, Andrew S; Birdzell, Maureen Gallagher; Cuomo, Frances; Di Paola, Matthew J; Zuckerman, Joseph D

    2010-06-01

    Previous studies have documented a decrease in proprioceptive capacity in the unstable shoulder. The degree to which surgical approach affects recovery of strength and proprioception is unknown. The recovery of strength and proprioception after open surgery for recurrent anterior glenohumeral instability was compared for 2 surgical procedures. A prospective analysis of 55 consecutive patients with posttraumatic unilateral recurrent anterior glenohumeral instability was performed. Thirty patients (group 1) underwent an open inferior capsular shift with detachment of the subscapularis, and 25 (group 2) underwent an anterior capsulolabral reconstruction. Mean preoperative proprioception and strength values were significantly lower for the affected shoulders in both groups. At 6 months after surgery, there were no significant differences for mean strength and proprioception values between the unaffected and operative sides for group 2 patients. In group 1 patients, however, there were still significant deficits in mean position sense and strength values. Complete restoration of proprioception and strength, however, was evident by 12 months in group 1. This study demonstrates that there are significant deficits in both strength and proprioception in patients with posttraumatic, recurrent anterior glenohumeral instability. Although both are completely restored by 1 year after surgery, a subscapularis-splitting approach allows for complete recovery of strength and position sense as early as 6 months postoperatively. Detachment of the subscapularis delays recovery of strength and position sense for up to 12 months after surgery. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  6. Surgical treatment of double thoracic adolescent idiopathic scoliosis with a rigid proximal thoracic curve.

    Science.gov (United States)

    Sudo, Hideki; Abe, Yuichiro; Abumi, Kuniyoshi; Iwasaki, Norimasa; Ito, Manabu

    2016-02-01

    There is limited consensus on the optimal surgical strategy for double thoracic adolescent idiopathic scoliosis (AIS). Recent studies have reported that