WorldWideScience

Sample records for partially occluded 3d

  1. Detection scheme for a partially occluded pedestrian based on occluded depth in lidar-radar sensor fusion

    Science.gov (United States)

    Kwon, Seong Kyung; Hyun, Eugin; Lee, Jin-Hee; Lee, Jonghun; Son, Sang Hyuk

    2017-11-01

    Object detections are critical technologies for the safety of pedestrians and drivers in autonomous vehicles. Above all, occluded pedestrian detection is still a challenging topic. We propose a new detection scheme for occluded pedestrian detection by means of lidar-radar sensor fusion. In the proposed method, the lidar and radar regions of interest (RoIs) have been selected based on the respective sensor measurement. Occluded depth is a new means to determine whether an occluded target exists or not. The occluded depth is a region projected out by expanding the longitudinal distance with maintaining the angle formed by the outermost two end points of the lidar RoI. The occlusion RoI is the overlapped region made by superimposing the radar RoI and the occluded depth. The object within the occlusion RoI is detected by the radar measurement information and the occluded object is estimated as a pedestrian based on human Doppler distribution. Additionally, various experiments are performed in detecting a partially occluded pedestrian in outdoor as well as indoor environments. According to experimental results, the proposed sensor fusion scheme has much better detection performance compared to the case without our proposed method.

  2. Transgastric endoscopic gastroenterostomy using a partially covered occluder: a canine feasibility study.

    Science.gov (United States)

    Luo, H; Pan, Y; Min, L; Zhao, L; Li, J; Leung, J; Xue, L; Yin, Z; Liu, X; Liu, Z; Sun, A; Li, C; Wu, K; Guo, X; Fan, D

    2012-05-01

    The use of natural orifice transluminal endoscopic surgery (NOTES) for gastroenterostomy has been previously reported, but it remains technically challenging and additional assistance is often needed. The aim of this study was to develop and evaluate a novel method for the creation of a gastroenterostomy using NOTES with an occluder. Transgastric endoscopic gastroenterostomy was performed in 12 healthy female dogs using a therapeutic upper gastrointestinal endoscope and a partially covered occluder. The occluder was removed with a snare 1 week later. The patency of the gastroenterostomy was confirmed by endoscopy, contrast radiological study, necropsy, and histological examination after 2 weeks. NOTES gastroenterostomy with an occluder was successful in all 12 dogs. The mean operative time was 32.3 ± 10.3 min (range 20.3 - 53.5). One dog (the first; 8.3 %) died 4 days after the operation of severe intra-abdominal infection due to incorrect deployment of the occluder and poor bowel preparation. Minor bleeding occurred at the anastomosis after removal of the occluder in two of the remaining dogs (18.2 %). Necropsy revealed postoperative adhesions that had developed at the anastomotic site in one dog (9.1 %). No anastomotic leakage or intestinal obstruction was observed. Complete healing of the anastomosis was confirmed on histological evaluation. Gastroenterostomy performed entirely by NOTES using an occluder was technically feasible in this survival animal model. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Reliable Recognition of Partially Occluded Objects with Correlation Filters

    Directory of Open Access Journals (Sweden)

    Alexey Ruchay

    2018-01-01

    Full Text Available Design of conventional correlation filters requires explicit knowledge of the appearance and shape of a target object, so the performance of correlation filters is significantly affected by changes in the appearance of the object in the input scene. In particular, the performance of correlation filters worsens when objects to be recognized are partially occluded by other objects, and the input scene contains a cluttered background and noise. In this paper, we propose a new algorithm for the design of a system consisting of a set of adaptive correlation filters for recognition of partially occluded objects in noisy scenes. Since the input scene may contain different fragments of the target, false objects, and background to be rejected, the system is designed in such a manner to guarantee equally high correlation peaks corresponding to parts of the target in the scenes. The key points of the system are as follows: (i it consists of a bank of composite optimum filters, which yield the best performance for different parts of the target; (ii it includes a fragmentation of the target into a given number of parts in the training stage to provide equal intensity responses of the system for each part of the target. With the help of computer simulation, the performance of the proposed algorithm for recognition partially occluded objects is compared with that of common algorithms in terms of objective metrics.

  4. Immediate occluding definitive partial fixed prosthesis versus non-occluding provisional restorations - 4-month post-loading results from a pragmatic multicenter randomised controlled trial.

    Science.gov (United States)

    Heinemann, Friedhelm; Grufferty, Brendan; Papavasiliou, George; Dominiak, Marzena; García, Jaime Jiménez; Trullenque-Eriksson, Anna; Esposito, Marco

    2016-01-01

    To compare the clinical outcome of dental implants restored with definitive occluding partial fixed prostheses within 1 week, after implant placement with immediate non-occluding provisional restorations, which were to be replaced by definitive prostheses after 4 months. Fifty partially edentulous patients treated with one to three dental implants, at least 8.5 mm long and 4.0 mm wide inserted with a torque of at least 35 Ncm, were randomised in two groups of 25 patients each, to be immediately loaded with partial fixed prostheses. Patients of one group received one definitive screw-retained metal-ceramic prosthesis in occlusion within 1 week after placement. Patients of the other group received one non-occluding provisional acrylic reinforced prosthesis within 24 h after implant placement. Provisional prostheses were replaced after 4 months by definitive ones. The follow-up for all patients was 4-months post-loading. Outcome measures were prosthesis and implant failures, any complications, peri-implant marginal bone level changes, aesthetic evaluation by a clinician, patient satisfaction, chair time and number of visits at the dental office from implant placement to delivery of definitive restorations. No patient dropped out. Two immediately occlusally loaded implants with their related definitive prostheses (8%) failed early (difference in proportions = 0.08; 95% CI: -0.03 to 0.19; P = 0.490). Four complications occurred in the occlusal group versus one in the non-occlusal group; (difference in proportions = 0.12; 95% CI: -0.04 to 0.28; P = 0.349). Four months after loading, patients subjected to non-occlusal loading lost an average of 0.72 mm of peri-implant bone versus 0.99 mm of patients restored with occluding definitive partial fixed prostheses. There were no statistically significant differences for marginal bone level changes between the two groups (mean difference = -0.27 mm; 95% CI: -0.84 to 0.30; P = 0.349). The differences for aesthetic scores showed

  5. 3-D vision and figure-ground separation by visual cortex.

    Science.gov (United States)

    Grossberg, S

    1994-01-01

    A neural network theory of three-dimensional (3-D) vision, called FACADE theory, is described. The theory proposes a solution of the classical figure-ground problem for biological vision. It does so by suggesting how boundary representations and surface representations are formed within a boundary contour system (BCS) and a feature contour system (FCS). The BCS and FCS interact reciprocally to form 3-D boundary and surface representations that are mutually consistent. Their interactions generate 3-D percepts wherein occluding and occluded object parts are separated, completed, and grouped. The theory clarifies how preattentive processes of 3-D perception and figure-ground separation interact reciprocally with attentive processes of spatial localization, object recognition, and visual search. A new theory of stereopsis is proposed that predicts how cells sensitive to multiple spatial frequencies, disparities, and orientations are combined by context-sensitive filtering, competition, and cooperation to form coherent BCS boundary segmentations. Several factors contribute to figure-ground pop-out, including: boundary contrast between spatially contiguous boundaries, whether due to scenic differences in luminance, color, spatial frequency, or disparity; partially ordered interactions from larger spatial scales and disparities to smaller scales and disparities; and surface filling-in restricted to regions surrounded by a connected boundary. Phenomena such as 3-D pop-out from a 2-D picture, Da Vinci stereopsis, 3-D neon color spreading, completion of partially occluded objects, and figure-ground reversals are analyzed. The BCS and FCS subsystems model aspects of how the two parvocellular cortical processing streams that join the lateral geniculate nucleus to prestriate cortical area V4 interact to generate a multiplexed representation of Form-And-Color-And-DEpth, or FACADE, within area V4. Area V4 is suggested to support figure-ground separation and to interact with

  6. Results of duct-occlud or nit-occlud device occlusion of patent ductus arteriousus

    International Nuclear Information System (INIS)

    Zhou Aiqing; Gao Wei; Yu Zhiqing; Li Feng; Wang Rongfa

    2003-01-01

    Objective: To evaluate the safety and efficacy of transcatheter patent ductus arteriosus (PDA) occlusion with the Duct-Occlud or Nit-Occlud device. Methods: All 68 patients with PDA (less than 4 mm minimum diameter) underwent percutaneous Duct-Occlud or Nit-Occlud coil occlusion in the Department of Cardiology, Shanghai Children's Medical Center between April 1997 and December 2001. The mean age was 5.5 ± 2.8 years (range, 1.5 to 12 years); mean weight was 13.9 ± 9.8 kg (range, 11.0 to 59.0 kg). The mean minimum diameter of the PDA was 1.63 ± 0.62 mm (range, 0.5-3.8 mm). Standard right and left retrograde heart catheterization were performed and followed by coil occlusion. A 4Fr or 5Fr catheter was used for coil deployment. Results: All patients had successful implantation of Duct-Occlud or Nit-Occlud devices. Patients follow-up evaluations were conducted at hospital discharge and after 3, 6 months and 1 year. At the discharge day and 1 year later, all patients showed complete PDA closure by color flow echo Doppler imaging. The hospitalization were only 5 days. At a median follow-up interval of 3.5 years (1 month to 4.6 years), there were no hemolysis, coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Conclusions: Because of the specifically designed coil with coincidental geometry of the ductus arteriosus, so transcatheter closure of PDA with the Duct-Occlud device is safe and effective for the closure of small-to-moderate-size patient ductus arteriosus. Utilization of Nit-Occlud is limited, but somewhat useful for large PDAs which is needed to be further investigated

  7. Results of duct-occlud or nit-occlud device occlusion of patent ductus arteriousus

    Energy Technology Data Exchange (ETDEWEB)

    Aiqing, Zhou; Wei, Gao; Zhiqing, Yu; Feng, Li; Rongfa, Wang [Shanghai Second Medical Univ., Shanghai (China). Shanghai Xinhua Hospital

    2003-10-01

    Objective: To evaluate the safety and efficacy of transcatheter patent ductus arteriosus (PDA) occlusion with the Duct-Occlud or Nit-Occlud device. Methods: All 68 patients with PDA (less than 4 mm minimum diameter) underwent percutaneous Duct-Occlud or Nit-Occlud coil occlusion in the Department of Cardiology, Shanghai Children's Medical Center between April 1997 and December 2001. The mean age was 5.5 {+-} 2.8 years (range, 1.5 to 12 years); mean weight was 13.9 {+-} 9.8 kg (range, 11.0 to 59.0 kg). The mean minimum diameter of the PDA was 1.63 {+-} 0.62 mm (range, 0.5-3.8 mm). Standard right and left retrograde heart catheterization were performed and followed by coil occlusion. A 4Fr or 5Fr catheter was used for coil deployment. Results: All patients had successful implantation of Duct-Occlud or Nit-Occlud devices. Patients follow-up evaluations were conducted at hospital discharge and after 3, 6 months and 1 year. At the discharge day and 1 year later, all patients showed complete PDA closure by color flow echo Doppler imaging. The hospitalization were only 5 days. At a median follow-up interval of 3.5 years (1 month to 4.6 years), there were no hemolysis, coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Conclusions: Because of the specifically designed coil with coincidental geometry of the ductus arteriosus, so transcatheter closure of PDA with the Duct-Occlud device is safe and effective for the closure of small-to-moderate-size patient ductus arteriosus. Utilization of Nit-Occlud is limited, but somewhat useful for large PDAs which is needed to be further investigated.

  8. Recognition of Simple 3D Geometrical Objects under Partial Occlusion

    Science.gov (United States)

    Barchunova, Alexandra; Sommer, Gerald

    In this paper we present a novel procedure for contour-based recognition of partially occluded three-dimensional objects. In our approach we use images of real and rendered objects whose contours have been deformed by a restricted change of the viewpoint. The preparatory part consists of contour extraction, preprocessing, local structure analysis and feature extraction. The main part deals with an extended construction and functionality of the classifier ensemble Adaptive Occlusion Classifier (AOC). It relies on a hierarchical fragmenting algorithm to perform a local structure analysis which is essential when dealing with occlusions. In the experimental part of this paper we present classification results for five classes of simple geometrical figures: prism, cylinder, half cylinder, a cube, and a bridge. We compare classification results for three classical feature extractors: Fourier descriptors, pseudo Zernike and Zernike moments.

  9. Occluded object reconstruction for first responders with augmented reality glasses using conditional generative adversarial networks

    OpenAIRE

    Yun, Kyongsik; Lu, Thomas; Chow, Edward

    2018-01-01

    Firefighters suffer a variety of life-threatening risks, including line-of-duty deaths, injuries, and exposures to hazardous substances. Support for reducing these risks is important. We built a partially occluded object reconstruction method on augmented reality glasses for first responders. We used a deep learning based on conditional generative adversarial networks to train associations between the various images of flammable and hazardous objects and their partially occluded counterparts....

  10. 3-D fracture analysis using a partial-reduced integration scheme

    International Nuclear Information System (INIS)

    Leitch, B.W.

    1987-01-01

    This paper presents details of 3-D elastic-plastic analyses of axially orientated external surface flaw in an internally pressurized thin-walled cylinder and discusses the variation of the J-integral values around the crack tip. A partial-reduced-integration-penalty method is introduced to minimize this variation of the J-integral near the crack tip. Utilizing 3-D symmetry, an eighth segment of a tube containing an elliptically shaped external surface flaw is modelled using 20-noded isoparametric elements. The crack-tip elements are collapsed to form a 1/r stress singularity about the curved crack front. The finite element model is subjected to internal pressure and axial pressure-generated loads. The virtual crack extension method is used to determine linear elastic stress intensity factors from the J-integral results at various points around the crack front. Despite the different material constants and the thinner wall thickness in this analysis, the elastic results compare favourably with those obtained by other researchers. The nonlinear stress-strain behaviour of the tube material is modelled using an incremental theory of plasticity. Variations of the J-integral values around the curved crack front of the 3-D flaw were seen. These variations could not be resolved by neglecting the immediate crack-tip elements J-integral results in favour of the more remote contour paths or else smoothed out when all the path results are averaged. Numerical incompatabilities in the 20-noded 3-D finite elements used to model the surface flaw were found. A partial-reduced integration scheme, using a combination of full and reduced integration elements, is proposed to determine J-integral results for 3-D fracture analyses. This procedure is applied to the analysis of an external semicircular surface flaw projecting halfway into the tube wall thickness. Examples of the J-integral values, before and after the partial-reduced integration method is employed, are given around the

  11. Influence of 3D effects on 1D aerosol retrievals in synthetic, partially clouded scenes

    International Nuclear Information System (INIS)

    Stap, F.A.; Hasekamp, O.P.; Emde, C.; Röckmann, T.

    2016-01-01

    An important challenge in aerosol remote sensing is to retrieve aerosol properties in the vicinity of clouds and in cloud contaminated scenes. Satellite based multi-wavelength, multi-angular, photo-polarimetric instruments are particularly suited for this task as they have the ability to separate scattering by aerosol and cloud particles. Simultaneous aerosol/cloud retrievals using 1D radiative transfer codes cannot account for 3D effects such as shadows, cloud induced enhancements and darkening of cloud edges. In this study we investigate what errors are introduced on the retrieved optical and micro-physical aerosol properties, when these 3D effects are neglected in retrievals where the partial cloud cover is modeled using the Independent Pixel Approximation. To this end a generic, synthetic data set of PARASOL like observations for 3D scenes with partial, liquid water cloud cover is created. It is found that in scenes with random cloud distributions (i.e. broken cloud fields) and either low cloud optical thickness or low cloud fraction, the inversion algorithm can fit the observations and retrieve optical and micro-physical aerosol properties with sufficient accuracy. In scenes with non-random cloud distributions (e.g. at the edge of a cloud field) the inversion algorithm can fit the observations, however, here the retrieved real part of the refractive indices of both modes is biased. - Highlights: • An algorithm for retrieval of both aerosol and cloud properties is presented. • Radiative transfer models of 3D, partially clouded scenes are simulated. • Errors introduced in the retrieved aerosol properties are discussed.

  12. Full Waveform Analysis for Long-Range 3D Imaging Laser Radar

    Directory of Open Access Journals (Sweden)

    Wallace AndrewM

    2010-01-01

    Full Text Available The new generation of 3D imaging systems based on laser radar (ladar offers significant advantages in defense and security applications. In particular, it is possible to retrieve 3D shape information directly from the scene and separate a target from background or foreground clutter by extracting a narrow depth range from the field of view by range gating, either in the sensor or by postprocessing. We discuss and demonstrate the applicability of full-waveform ladar to produce multilayer 3D imagery, in which each pixel produces a complex temporal response that describes the scene structure. Such complexity caused by multiple and distributed reflection arises in many relevant scenarios, for example in viewing partially occluded targets, through semitransparent materials (e.g., windows and through distributed reflective media such as foliage. We demonstrate our methodology on 3D image data acquired by a scanning time-of-flight system, developed in our own laboratories, which uses the time-correlated single-photon counting technique.

  13. Whole object surface area and volume of partial-view 3D models

    International Nuclear Information System (INIS)

    Mulukutla, Gopal K; Proussevitch, Alexander A; Genareau, Kimberly D; Durant, Adam J

    2017-01-01

    Micro-scale 3D models, important components of many studies in science and engineering, are often used to determine morphological characteristics such as shape, surface area and volume. The application of techniques such as stereoscopic scanning electron microscopy on whole objects often results in ‘partial-view’ models with a portion of object not within the field of view thus not captured in the 3D model. The nature and extent of the surface not captured is dependent on the complex interaction of imaging system attributes (e.g. working distance, viewing angle) with object size, shape and morphology. As a result, any simplistic assumptions in estimating whole object surface area or volume can lead to significant errors. In this study, we report on a novel technique to estimate the physical fraction of an object captured in a partial-view 3D model of an otherwise whole object. This allows a more accurate estimate of surface area and volume. Using 3D models, we demonstrate the robustness of this method and the accuracy of surface area and volume estimates relative to true values. (paper)

  14. Coupling 2D/3D registration method and statistical model to perform 3D reconstruction from partial x-rays images data.

    Science.gov (United States)

    Cresson, T; Chav, R; Branchaud, D; Humbert, L; Godbout, B; Aubert, B; Skalli, W; De Guise, J A

    2009-01-01

    3D reconstructions of the spine from a frontal and sagittal radiographs is extremely challenging. The overlying features of soft tissues and air cavities interfere with image processing. It is also difficult to obtain information that is accurate enough to reconstruct complete 3D models. To overcome these problems, the proposed method efficiently combines the partial information contained in two images from a patient with a statistical 3D spine model generated from a database of scoliotic patients. The algorithm operates through two simultaneous iterating processes. The first one generates a personalized vertebra model using a 2D/3D registration process with bone boundaries extracted from radiographs, while the other one infers the position and the shape of other vertebrae from the current estimation of the registration process using a statistical 3D model. Experimental evaluations have shown good performances of the proposed approach in terms of accuracy and robustness when compared to CT-scan.

  15. Towards Robust and Accurate Multi-View and Partially-Occluded Face Alignment.

    Science.gov (United States)

    Xing, Junliang; Niu, Zhiheng; Huang, Junshi; Hu, Weiming; Zhou, Xi; Yan, Shuicheng

    2018-04-01

    Face alignment acts as an important task in computer vision. Regression-based methods currently dominate the approach to solving this problem, which generally employ a series of mapping functions from the face appearance to iteratively update the face shape hypothesis. One keypoint here is thus how to perform the regression procedure. In this work, we formulate this regression procedure as a sparse coding problem. We learn two relational dictionaries, one for the face appearance and the other one for the face shape, with coupled reconstruction coefficient to capture their underlying relationships. To deploy this model for face alignment, we derive the relational dictionaries in a stage-wised manner to perform close-loop refinement of themselves, i.e., the face appearance dictionary is first learned from the face shape dictionary and then used to update the face shape hypothesis, and the updated face shape dictionary from the shape hypothesis is in return used to refine the face appearance dictionary. To improve the model accuracy, we extend this model hierarchically from the whole face shape to face part shapes, thus both the global and local view variations of a face are captured. To locate facial landmarks under occlusions, we further introduce an occlusion dictionary into the face appearance dictionary to recover face shape from partially occluded face appearance. The occlusion dictionary is learned in a data driven manner from background images to represent a set of elemental occlusion patterns, a sparse combination of which models various practical partial face occlusions. By integrating all these technical innovations, we obtain a robust and accurate approach to locate facial landmarks under different face views and possibly severe occlusions for face images in the wild. Extensive experimental analyses and evaluations on different benchmark datasets, as well as two new datasets built by ourselves, have demonstrated the robustness and accuracy of our proposed

  16. Acoustic position finding of partial discharges in transformers. Combination of partial discharge measurement technology with 3D visualization; Akustische Ortung von Teilentladungen in Transformatoren. TE-Messtechnik und 3-D-Visualisierung kombiniert

    Energy Technology Data Exchange (ETDEWEB)

    Kraetge, Alexander; Hoek, Stefan [Omicron Electronics GmbH, Klaus (Austria)

    2013-11-01

    A new measuring system facilitates the detection of partial discharges in transformers by means of the fully synchronous combination of measurement technology for electrical partial discharges with intuitive 3D visualization of the test object. The contribution under consideration describes the application of this system with examples from the measurement practice.

  17. ANNOTATION SUPPORTED OCCLUDED OBJECT TRACKING

    Directory of Open Access Journals (Sweden)

    Devinder Kumar

    2012-08-01

    Full Text Available Tracking occluded objects at different depths has become as extremely important component of study for any video sequence having wide applications in object tracking, scene recognition, coding, editing the videos and mosaicking. The paper studies the ability of annotation to track the occluded object based on pyramids with variation in depth further establishing a threshold at which the ability of the system to track the occluded object fails. Image annotation is applied on 3 similar video sequences varying in depth. In the experiment, one bike occludes the other at a depth of 60cm, 80cm and 100cm respectively. Another experiment is performed on tracking humans with similar depth to authenticate the results. The paper also computes the frame by frame error incurred by the system, supported by detailed simulations. This system can be effectively used to analyze the error in motion tracking and further correcting the error leading to flawless tracking. This can be of great interest to computer scientists while designing surveillance systems etc.

  18. Long-Term Primary Patency Rate After Nitinol Self-Expandable Stents Implantation in Long, Totally Occluded Femoropopliteal (TASC II C & D) Lesions.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; Buonamici, Piergiovanni; Trapani, Maurizio; Valenti, Renato; Migliorini, Angela; Parodi, Guido; Antoniucci, David

    2017-06-01

    Endovascular therapy for long femoropopliteal lesions using percutaneous transluminal balloon angioplasty or first-generation of peripheral stents has been associated with unacceptable one-year restenosis rates. However, with recent advances in equipment and techniques, a better primary patency rate is expected. This study was conducted to detect the long-term primary patency rate of nitinol self-expandable stents implanted in long, totally occluded femoropopliteal lesions TransAtlantic Inter-Society Census (TASC II type C & D), and determine the predictors of reocclusion or restenosis in the stented segments. The demographics, clinical, anatomical, and procedural data of 213 patients with 240 de novo totally occluded femoropopliteal (TASC II type C & D) lesions treated with nitinol self-expandable stents were retrospectively analysed. Of these limbs, 159 (66.2%) presented with intermittent claudication, while 81 (33.8%) presented with critical limb ischaemia. The mean-time of follow-up was 36±22.6 months, (range: 6.3-106.2 months). Outcomes evaluated were, primary patency rate and predictors of reocclusion or restenosis in the stented segments. The mean age of the patients was 70.9±9.3 years, with male gender 66.2%. Mean pre-procedural ABI was 0.45±0.53. One-hundred-and-seventy-five (73%) lesions were TASC II type C, while 65 (27%) were type D lesions. The mean length of the lesions was 17.9±11.3mm. Procedure related complications occurred in 10 (4.1%) limbs. There was no periprocedural mortality. Reocclusion and restenosis were detected during follow-up in 45 and 30 limbs respectively, and all were re-treated by endovascular approach. None of the patients required major amputation. Primary patency rates were 81.4±1.1%, 77.7±1.9% and 74.4±2.8% at 12, 24, and 36 months respectively. Male gender, severe calcification, and TASC II D lesion were independent predictors for reocclusion, while predictors of restenosis were DM, smoking and TASC II D lesions

  19. Cortical Dynamics of Figure-Ground Separation in Response to 2D Pictures and 3D Scenes: How V2 Combines Border Ownership, Stereoscopic Cues, and Gestalt Grouping Rules

    OpenAIRE

    Grossberg, Stephen

    2016-01-01

    The FACADE model, and its laminar cortical realization and extension in the 3D LAMINART model, have explained, simulated, and predicted many perceptual and neurobiological data about how the visual cortex carries out 3D vision and figure-ground perception, and how these cortical mechanisms enable 2D pictures to generate 3D percepts of occluding and occluded objects. In particular, these models have proposed how border ownership occurs, but have not yet explicitly explained the correlation bet...

  20. Weight dependent modulation of motor resonance induced by weight estimation during observation of partially occluded lifting actions.

    Science.gov (United States)

    Valchev, Nikola; Zijdewind, Inge; Keysers, Christian; Gazzola, Valeria; Avenanti, Alessio; Maurits, Natasha M

    2015-01-01

    Seeing others performing an action induces the observers' motor cortex to "resonate" with the observed action. Transcranial magnetic stimulation (TMS) studies suggest that such motor resonance reflects the encoding of various motor features of the observed action, including the apparent motor effort. However, it is unclear whether such encoding requires direct observation or whether force requirements can be inferred when the moving body part is partially occluded. To address this issue, we presented participants with videos of a right hand lifting a box of three different weights and asked them to estimate its weight. During each trial we delivered one transcranial magnetic stimulation (TMS) pulse over the left primary motor cortex of the observer and recorded the motor evoked potentials (MEPs) from three muscles of the right hand (first dorsal interosseous, FDI, abductor digiti minimi, ADM, and brachioradialis, BR). Importantly, because the hand shown in the videos was hidden behind a screen, only the contractions in the actor's BR muscle under the bare skin were observable during the entire videos, while the contractions in the actor's FDI and ADM muscles were hidden during the grasp and actual lift. The amplitudes of the MEPs recorded from the BR (observable) and FDI (hidden) muscle increased with the weight of the box. These findings indicate that the modulation of motor excitability induced by action observation extends to the cortical representation of muscles with contractions that could not be observed. Thus, motor resonance appears to reflect force requirements of observed lifting actions even when the moving body part is occluded from view. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Factors Affecting Infants’ Manual Search for Occluded Objects and the Genesis of Object Permanence

    Science.gov (United States)

    Moore, M. Keith; Meltzoff, Andrew N.

    2009-01-01

    Two experiments systematically examined factors that influence infants’ manual search for hidden objects (N = 96). Experiment 1 used a new procedure to assess infants’ search for partially versus totally occluded objects. Results showed that 8.75-month-old infants solved partial occlusions by removing the occluder and uncovering the object, but these same infants failed to use this skill on total occlusions. Experiment 2 used sound-producing objects to provide a perceptual clue to the objects’ hidden location. Sound clues significantly increased the success rate on total occlusions for 10-month-olds, but not for 8.75-month-olds. An identity development account is offered for why infants succeed on partial occlusions earlier than total occlusions and why sound helps only the older infants. We propose a mechanism for how infants use object identity as a basis for developing a notion of permanence. Implications are drawn for understanding the dissociation between looking-time and search assessments of object permanence. PMID:18036668

  2. Factors affecting infants' manual search for occluded objects and the genesis of object permanence.

    Science.gov (United States)

    Moore, M Keith; Meltzoff, Andrew N

    2008-04-01

    Two experiments systematically examined factors that influence infants' manual search for hidden objects (N=96). Experiment 1 used a new procedure to assess infants' search for partially versus totally occluded objects. Results showed that 8.75-month-old infants solved partial occlusions by removing the occluder and uncovering the object, but these same infants failed to use this skill on total occlusions. Experiment 2 used sound-producing objects to provide a perceptual clue to the objects' hidden location. Sound clues significantly increased the success rate on total occlusions for 10-month-olds, but not for 8.75-month-olds. An identity development account is offered for why infants succeed on partial occlusions earlier than total occlusions and why sound helps only the older infants. We propose a mechanism for how infants use object identity as a basis for developing a notion of permanence. Implications are drawn for understanding the dissociation between looking time and search assessments of object permanence.

  3. Quantitative evaluation of temporal partial coherence using 3D Fourier transforms of through-focus TEM images

    International Nuclear Information System (INIS)

    Kimoto, Koji; Sawada, Hidetaka; Sasaki, Takeo; Sato, Yuta; Nagai, Takuro; Ohwada, Megumi; Suenaga, Kazu; Ishizuka, Kazuo

    2013-01-01

    We evaluate the temporal partial coherence of transmission electron microscopy (TEM) using the three-dimensional (3D) Fourier transform (FT) of through-focus images. Young's fringe method often indicates the unexpected high-frequency information due to non-linear imaging terms. We have already used the 3D FT of axial (non-tilted) through-focus images to reduce the effect of non-linear terms on the linear imaging term, and demonstrated the improvement of monochromated lower-voltage TEM performance [Kimoto et al., Ultramicroscopy 121 (2012) 31–39]. Here we apply the 3D FT method with intentionally tilted incidence to normalize various factors associated with a TEM specimen and an imaging device. The temporal partial coherence of two microscopes operated at 30, 60 and 80 kV is evaluated. Our method is applicable to such cases where the non-linear terms become more significant in lower acceleration voltage or aberration-corrected high spatial resolution TEM. - Highlights: • We assess the temporal partial coherence of TEM using a 3-dimensional (3D) Fourier transform (FT) of through-focus images. • We apply the 3D FT method with intentionally tilted incidence to normalize various factors associated with a TEM specimen and an imaging device. • The spatial frequency at which information transfer decreases to 1/e 2 (13.5%) is determined for two lower-voltage TEM systems

  4. Closure of large patent ductus arteriosus using the Amplatzer Septal Occluder.

    Science.gov (United States)

    García-Montes, José A; Camacho-Castro, Anahí; Sandoval-Jones, Juan P; Buendía-Hernández, Alfonso; Calderón-Colmenero, Juan; Patiño-Bahena, Emilia; Zabal, Carlos

    2015-03-01

    Percutaneous closure of patent ductus arteriosus has become the treatment of choice in many centres. In patients with large ducts and pulmonary hypertension, transcatheter closure has been achieved with success using the Amplatzer Duct Occluder or even the Amplatzer Muscular Ventricular Septal Defect Occluder. We present a series of 17 patients with large and hypertensive ductus arteriosus who were treated with an Amplatzer Septal Occluder. The group had 11 female patients (64.7%) and a mean age of 18.6±12.1 years. The haemodynamic and anatomical data are as follows: pulmonary artery systolic pressure 71.3±31.8 mmHg, pulmonary to systemic flow ratio 3.14±1.36, ductal diameter at the pulmonary end 12.5±3.8 mm, and at the aortic end 20.2±7.7 mm; 14 cases (82.3%) had type A ducts. In 11 patients, we began the procedure using a different device - six with duct occluder and five with ventricular septal occluder - and it was changed because of device embolisation in six (35.3%). All septal occluders were delivered successfully. Residual shunt was moderate in six patients (35.3%), mild in eight (47%), trivial in two (11.8%), and no shunt in one (5.9%). Pulmonary systolic pressure decreased to 48.9±10.8 mmHg after occlusion (p=0.0015). Follow-up in 15 patients (88.2%) for 28.4±14.4 months showed complete closure in all cases but one, and continuous decrease of the pulmonary systolic pressure to 31.4±10.5 mmHg. No complications at follow-up have been reported. The Amplatzer Septal Occluder is a good alternative to percutaneously treat large and hypertensive ductus arteriosus.

  5. Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration.

    Science.gov (United States)

    Su, Li-Ming; Vagvolgyi, Balazs P; Agarwal, Rahul; Reiley, Carol E; Taylor, Russell H; Hager, Gregory D

    2009-04-01

    To investigate a markerless tracking system for real-time stereo-endoscopic visualization of preoperative computed tomographic imaging as an augmented display during robot-assisted laparoscopic partial nephrectomy. Stereoscopic video segments of a patient undergoing robot-assisted laparoscopic partial nephrectomy for tumor and another for a partial staghorn renal calculus were processed to evaluate the performance of a three-dimensional (3D)-to-3D registration algorithm. After both cases, we registered a segment of the video recording to the corresponding preoperative 3D-computed tomography image. After calibrating the camera and overlay, 3D-to-3D registration was created between the model and the surgical recording using a modified iterative closest point technique. Image-based tracking technology tracked selected fixed points on the kidney surface to augment the image-to-model registration. Our investigation has demonstrated that we can identify and track the kidney surface in real time when applied to intraoperative video recordings and overlay the 3D models of the kidney, tumor (or stone), and collecting system semitransparently. Using a basic computer research platform, we achieved an update rate of 10 Hz and an overlay latency of 4 frames. The accuracy of the 3D registration was 1 mm. Augmented reality overlay of reconstructed 3D-computed tomography images onto real-time stereo video footage is possible using iterative closest point and image-based surface tracking technology that does not use external navigation tracking systems or preplaced surface markers. Additional studies are needed to assess the precision and to achieve fully automated registration and display for intraoperative use.

  6. ExpNet: Landmark-Free, Deep, 3D Facial Expressions

    OpenAIRE

    Chang, Feng-Ju; Tran, Anh Tuan; Hassner, Tal; Masi, Iacopo; Nevatia, Ram; Medioni, Gerard

    2018-01-01

    We describe a deep learning based method for estimating 3D facial expression coefficients. Unlike previous work, our process does not relay on facial landmark detection methods as a proxy step. Recent methods have shown that a CNN can be trained to regress accurate and discriminative 3D morphable model (3DMM) representations, directly from image intensities. By foregoing facial landmark detection, these methods were able to estimate shapes for occluded faces appearing in unprecedented in-the-...

  7. Three-year outcomes of a once daily fractionation scheme for accelerated partial breast irradiation (APBI) using 3-D conformal radiotherapy (3D-CRT)

    International Nuclear Information System (INIS)

    Goyal, Sharad; Daroui, Parima; Khan, Atif J; Kearney, Thomas; Kirstein, Laurie; Haffty, Bruce G

    2013-01-01

    The aim of this study was to report 3-year outcomes of toxicity, cosmesis, and local control using a once daily fractionation scheme (49.95 Gy in 3.33 Gy once daily fractions) for accelerated partial breast irradiation (APBI) using three-dimensional conformal radiotherapy (3D-CRT). Between July 2008 and August 2010, women aged ≥40 years with ductal carcinoma in situ or node-negative invasive breast cancer ≤3 cm in diameter, treated with breast-conserving surgery achieving negative margins, were accrued to a prospective study. Women were treated with APBI using 3–5 photon beams, delivering 49.95 Gy over 15 once daily fractions over 3 weeks. Patients were assessed for toxicities, cosmesis, and local control rates before APBI and at specified time points. Thirty-four patients (mean age 60 years) with Tis 0 (n = 9) and T1N0 (n = 25) breast cancer were treated and followed up for an average of 39 months. Only 3% (1/34) patients experienced a grade 3 subcutaneous fibrosis and breast edema and 97% of the patients had good/excellent cosmetic outcome at 3 years. The 3-year rate of ipsilateral breast tumor recurrence (IBTR) was 0% while the rate of contralateral breast events was 6%. The 3-year disease-free survival (DFS), overall survival (OS), and breast cancer-specific survival (BCSS) was 94%, 100%, and 100%, respectively. Our novel accelerated partial breast fractionation scheme of 15 once daily fractions of 3.33 Gy (49.95 Gy total) is a remarkably well-tolerated regimen of 3D-CRT-based APBI. A larger cohort of patients is needed to further ascertain the toxicity of this accelerated partial breast regimen

  8. Catching what we can't see: manual interception of occluded fly-ball trajectories.

    Science.gov (United States)

    Bosco, Gianfranco; Delle Monache, Sergio; Lacquaniti, Francesco

    2012-01-01

    Control of interceptive actions may involve fine interplay between feedback-based and predictive mechanisms. These processes rely heavily on target motion information available when the target is visible. However, short-term visual memory signals as well as implicit knowledge about the environment may also contribute to elaborate a predictive representation of the target trajectory, especially when visual feedback is partially unavailable because other objects occlude the visual target. To determine how different processes and information sources are integrated in the control of the interceptive action, we manipulated a computer-generated visual environment representing a baseball game. Twenty-four subjects intercepted fly-ball trajectories by moving a mouse cursor and by indicating the interception with a button press. In two separate sessions, fly-ball trajectories were either fully visible or occluded for 750, 1000 or 1250 ms before ball landing. Natural ball motion was perturbed during the descending trajectory with effects of either weightlessness (0 g) or increased gravity (2 g) at times such that, for occluded trajectories, 500 ms of perturbed motion were visible before ball disappearance. To examine the contribution of previous visual experience with the perturbed trajectories to the interception of invisible targets, the order of visible and occluded sessions was permuted among subjects. Under these experimental conditions, we showed that, with fully visible targets, subjects combined servo-control and predictive strategies. Instead, when intercepting occluded targets, subjects relied mostly on predictive mechanisms based, however, on different type of information depending on previous visual experience. In fact, subjects without prior experience of the perturbed trajectories showed interceptive errors consistent with predictive estimates of the ball trajectory based on a-priori knowledge of gravity. Conversely, the interceptive responses of subjects

  9. A comparative study assessing a new tool for occluding ...

    African Journals Online (AJOL)

    0.630, p=0.068 and p=0.047, respectively) (Table 2). A comparative study assessing a new tool for occluding parenchymal blood flow during liver resection for hepatocellular carcinoma. S Zhou, X-J Xue, R-R Li, D-F Chen, W-Y Chen, G-X Liu, ...

  10. Patent ductus arteriosus closure using Occlutech® Duct Occluder, experience in Port Elizabeth, South Africa.

    Science.gov (United States)

    Pepeta, Lungile; Greyling, Adele; Nxele, Mahlubandile Fintan; Makrexeni, Zongezile Masonwabe

    2017-01-01

    Percutaneous closure of patent ductus arteriosus (PDA) has become standard therapy. Experience with the Occlutech® Duct Occluder is limited. Data regarding ductal closure using Occlutech® Duct Occluder were reviewed and prospectively collected. Demographics, hemodynamic and angiographic characteristics, complications, and outcomes were documented. From March 2013 to June 2016, 65 patients (43 females and 22 males) underwent percutaneous closure of the PDA using Occlutech® Duct Occluder. The median age of the patients was 11 months (range, 1-454 months) and the median weight was 8.5 kg (range 2.5-78 kg). The mean pulmonary artery median pressure was 27 mmHg (range, 12-100 mmHg) and the QP: Qs ratio median was 1.8 (range, 1-7.5), with a pulmonary vascular resistance mean of 2.7 WU (standard deviation [SD] ±2.1). Thirty-two patients had Krichenko Type A duct (49%); 7, Type C (11%); 4, Type D (6%); and 22, Type E (34%). The ductal size (narrowest diameter at the pulmonic end) mean was 3.5 mm (SD ± 1.9 mm). The screening time mean was 17.3 min (SD ± 11.6). Out of 63 patients with successful closure of the PDA using Occlutech® Duct Occluder, there were 15 patients with small PDAs; 25 with moderate PDAs, and 23 with large PDAs. In one patient, the device dislodged to the descending aorta, and in two patients, to the right pulmonary artery immediately following deployment, with successful percutaneous (two) and surgical (one) retrieval. Complete ductal occlusion was achieved in all 63 patients on day one. The Occlutech® Duct Occluder is a safe and effective device for closure of ducts in appropriately selected patients.

  11. Catching what we can't see: manual interception of occluded fly-ball trajectories.

    Directory of Open Access Journals (Sweden)

    Gianfranco Bosco

    Full Text Available Control of interceptive actions may involve fine interplay between feedback-based and predictive mechanisms. These processes rely heavily on target motion information available when the target is visible. However, short-term visual memory signals as well as implicit knowledge about the environment may also contribute to elaborate a predictive representation of the target trajectory, especially when visual feedback is partially unavailable because other objects occlude the visual target. To determine how different processes and information sources are integrated in the control of the interceptive action, we manipulated a computer-generated visual environment representing a baseball game. Twenty-four subjects intercepted fly-ball trajectories by moving a mouse cursor and by indicating the interception with a button press. In two separate sessions, fly-ball trajectories were either fully visible or occluded for 750, 1000 or 1250 ms before ball landing. Natural ball motion was perturbed during the descending trajectory with effects of either weightlessness (0 g or increased gravity (2 g at times such that, for occluded trajectories, 500 ms of perturbed motion were visible before ball disappearance. To examine the contribution of previous visual experience with the perturbed trajectories to the interception of invisible targets, the order of visible and occluded sessions was permuted among subjects. Under these experimental conditions, we showed that, with fully visible targets, subjects combined servo-control and predictive strategies. Instead, when intercepting occluded targets, subjects relied mostly on predictive mechanisms based, however, on different type of information depending on previous visual experience. In fact, subjects without prior experience of the perturbed trajectories showed interceptive errors consistent with predictive estimates of the ball trajectory based on a-priori knowledge of gravity. Conversely, the interceptive responses

  12. Modeling tree crown dynamics with 3D partial differential equations.

    Science.gov (United States)

    Beyer, Robert; Letort, Véronique; Cournède, Paul-Henry

    2014-01-01

    We characterize a tree's spatial foliage distribution by the local leaf area density. Considering this spatially continuous variable allows to describe the spatiotemporal evolution of the tree crown by means of 3D partial differential equations. These offer a framework to rigorously take locally and adaptively acting effects into account, notably the growth toward light. Biomass production through photosynthesis and the allocation to foliage and wood are readily included in this model framework. The system of equations stands out due to its inherent dynamic property of self-organization and spontaneous adaptation, generating complex behavior from even only a few parameters. The density-based approach yields spatially structured tree crowns without relying on detailed geometry. We present the methodological fundamentals of such a modeling approach and discuss further prospects and applications.

  13. Effects of heating on salt-occluded zeolite

    International Nuclear Information System (INIS)

    Lewis, M.A.; Hash, M.C.; Pereira, C.; Ackerman, J.P.

    1996-01-01

    The electrometallurgical treatment of spent nuclear fuel generates a waste stream of fission products in the electrolyte, LiCl-KCl eutectic salt. Argonne National Laboratory is developing a mineral waste form for this waste stream. The waste form consists of a composite formed by hot pressing salt-occluded zeolite and a glass binder. Pressing conditions must be judiciously chosen. For a given pressure, increasing temperatures and hold times give denser products but the zeolite is frequently converted to sodalite. Reducing the temperature or hold time leads to a porous zeolite composite. Therefore, conditions that affect the thermal stability of salt-occluded zeolite both with and without glass are being investigated in an ongoing study. The parameters varied in this stage of the work were heating time, temperature, salt loading, and glass content. The heat-treated samples were examined primarily by X-ray diffraction. Large variations were found in the rate at which salt-occluded zeolite converted to other phases such as nepheline, salt, and sodalite. The products depended on the initial salt loading. Heating times required for these transitions depended on the procedure and temperature used to prepare the salt-occluded zeolite. Mixtures of glass and zeolite reacted much faster than the pure salt-occluded zeolite and were almost always converted to sodalite

  14. Kalisphera: an analytical tool to reproduce the partial volume effect of spheres imaged in 3D

    International Nuclear Information System (INIS)

    Tengattini, Alessandro; Andò, Edward

    2015-01-01

    In experimental mechanics, where 3D imaging is having a profound effect, spheres are commonly adopted for their simplicity and for the ease of their modeling. In this contribution we develop an analytical tool, ‘kalisphera’, to produce 3D raster images of spheres including their partial volume effect. This allows us to evaluate the metrological performance of existing image-based measurement techniques (knowing a priori the ground truth). An advanced application of ‘kalisphera’ is developed here to identify and accurately characterize spheres in real 3D x-ray tomography images with the objective of improving trinarization and contact detection. The effect of the common experimental imperfections is assessed and the overall performance of the tool tested on real images. (paper)

  15. Oxygen Partial Pressure Is a Rate-Limiting Parameter for Cell Proliferation in 3D Spheroids Grown in Physioxic Culture Condition.

    Science.gov (United States)

    Gomes, Aurélie; Guillaume, Ludivine; Grimes, David Robert; Fehrenbach, Jérôme; Lobjois, Valérie; Ducommun, Bernard

    2016-01-01

    The in situ oxygen partial pressure in normal and tumor tissues is in the range of a few percent. Therefore, when studying cell growth in 3D culture systems, it is essential to consider how the physiological oxygen concentration, rather than the one in the ambient air, influences the proliferation parameters. Here, we investigated the effect of reducing oxygen partial pressure from 21% to 5% on cell proliferation rate and regionalization in a 3D tumor spheroid model. We found that 5% oxygen concentration strongly inhibited spheroid growth, changed the proliferation gradient and reduced the 50% In Depth Proliferation index (IDP50), compared with culture at 21% oxygen. We then modeled the oxygen partial pressure profiles using the experimental data generated by culturing spheroids in physioxic and normoxic conditions. Although hypoxia occurred at similar depth in spheroids grown in the two conditions, oxygen partial pressure was a major rate-limiting factor with a critical effect on cell proliferation rate and regionalization only in spheroids grown in physioxic condition and not in spheroids grown at atmospheric normoxia. Our findings strengthen the need to consider conducting experiment in physioxic conditions (i.e., tissue normoxia) for proper understanding of cancer cell biology and the evaluation of anticancer drugs in 3D culture systems.

  16. [Percutaneous closure of the patent ductus arteriosus in children with the Amplatzer Duct Occluder II].

    Science.gov (United States)

    Parra-Bravo, José Rafael; Osuna-Izaguirre, Manuel Alfredo; Beirana-Palencia, Luisa; Gálvez-Cancino, Franco; Martínez-Monterrosas, Christian; Lazo-Cárdenas, César; Reyes-Vargas, César

    2014-01-01

    In the last decades, several devices have been used for the percutaneous closure of patent ductus arteriosus, with its own limitations and risks. The Amplatzer Duct Occluder II has been designed to overcome those limitations and reduce risks. We described our initial series of patients who underwent percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder II, emphasis on the technical aspects of the procedure. We reviewed the clinical records of 9 patients with patent ductus arteriosus who underwent percutaneous closure with the Amplatzer Duct Occluder II. Median age was 24 months (range 8-51 months) and the median weight was 10.7kg (range 6-16.3kg). The minimal ductus arteriosus diameter was 2.7mm (1-5mm). Implantation was successful in all cases. The devices most commonly used (33.3%) were the dimensions 4-4mm (3 patients), in 2 patients were used 3-4mm and in the rest of the patients were employed occluder other sizes. Four cases showed slight residual flow immediately after implantation. Total closure was achieved in 24h in 8 of 9 patients (89%). There was no embolization of the occluder or deaths during the procedure and we only observed one minor complication. The Amplatzer Duct Occluder II in this series was effective in 89% of the patients at 24hs after the procedure and 100% follow-up. The implantation was safe and no major complications were observed. The occlusion rate is comparable to those reported for the Amplatzer Duct Occluder I. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  17. Mass transport and chloride ion complexes in occluded cell

    International Nuclear Information System (INIS)

    Tsuru, T.; Hashimoto, K.; Nishikata, A.; Haruyama, S.

    1989-01-01

    Changes in the transport and the concentration of ions in a model occluded cell are traced during galvanostatic anodic polarization of a mild steel and a stainless steel. Apparent transport numbers of anions and cations, which were estimated from chemical analysis of solution, were different from those calculated from known mobility data. At the initial stage of the polarization, the transport number of chloride ion was almost unity, and then decreased gradually. For the mild steel, the concentration of total chloride ion accumulated in the occluded compartment increased with the anodic charge passed, and the amount of chloride ion complexed with cations also increased. The chloride complex was estimated as FeCl + . For SUS304 stainless steel, the total chloride ion increased, however, the free chloride ion, which responded to an Ag/AgCl electrode remained approximately 2 mol/dm 3 . Therefore, most of the chloride ions transferred into the occluded cell formed complex ions, such as CrCl n 3-n . The number of chloride ion coordinated to ferrous and chromic ions was estimated from the data fo mass transport for the case of the mild steel and the stainless steel. (author) 9 refs., 14 figs

  18. 3D noise-resistant segmentation and tracking of unknown and occluded objects using integral imaging

    Science.gov (United States)

    Aloni, Doron; Jung, Jae-Hyun; Yitzhaky, Yitzhak

    2017-10-01

    Three dimensional (3D) object segmentation and tracking can be useful in various computer vision applications, such as: object surveillance for security uses, robot navigation, etc. We present a method for 3D multiple-object tracking using computational integral imaging, based on accurate 3D object segmentation. The method does not employ object detection by motion analysis in a video as conventionally performed (such as background subtraction or block matching). This means that the movement properties do not significantly affect the detection quality. The object detection is performed by analyzing static 3D image data obtained through computational integral imaging With regard to previous works that used integral imaging data in such a scenario, the proposed method performs the 3D tracking of objects without prior information about the objects in the scene, and it is found efficient under severe noise conditions.

  19. Characterization and partial purification of beta-1,3-D-glucan (callose) synthase from barley (Hordeum vulgare) leaves

    DEFF Research Database (Denmark)

    Pedersen, L.H.; Jacobsen, S.; Hejgaard, J.

    1993-01-01

    The plasma membrane bound beta-1,3-D-glucan (callose) synthase. assumed to be involved in the resistance to the powdery mildew fungus (Erysiphe graminis f.sp. hordei), was partially purified from a microsomal fraction of green barley leaves (Hordeum vulgare L.). Plasma membranes were enriched...

  20. Postinfarct VSD management using 3D computer printing assisted percutaneous closure

    Directory of Open Access Journals (Sweden)

    Mohamad Lazkani

    2015-11-01

    Full Text Available Postinfarct VSD (PIVSD carries a grim prognosis. The mainstay of management has been surgical repair. The advent of septal occluder devices has offered an attractive alternative to surgical repair. Most PIVSD have serpiginous tracts with necrotic tissue, which makes assessing the defect challenging. 3D computer printing has become useful in preprocedure planning of complex surgical procedures in multiple subspecialties.

  1. Evaluation on occluded hydrocarbon in deep–ultra deep ancient source rocks and its cracked gas resources

    Directory of Open Access Journals (Sweden)

    Jian Li

    2015-12-01

    Full Text Available Oil-cracked gas, as the main type of high-over mature marine natural gas in China, is mainly derived from occluded hydrocarbon. So it is significant to carry out quantitative study on occluded hydrocarbon. In this paper, the occluded hydrocarbon volume of the main basins in China was calculated depending on their types, abundances and evolution stages by means of the forward method (experimental simulation and the inversion method (geologic profile dissection. And then, occluded hydrocarbon evolution models were established for five types of source rocks (sapropelic, sapropelic prone hybrid, humic prone hybrid, humic and coal. It is shown that the hydrocarbon expulsion efficiency of sapropelic and sapropelic prone hybrid excellent source rocks is lower than 30% at the low-maturity stage, 30%–60% at the principal oil generation stage, and 50%–80% at the high-maturity stage, which are all about 10% higher than that of humic prone hybrid and humic source rocks at the corresponding stages. The resource distribution and cracked gas expulsion of occluded hydrocarbon since the high-maturity stage of marine source rocks in the Sichuan Basin were preliminarily calculated on the basis of the evolution models. The cracked gas expulsion is 230.4 × 1012 m3 at the high evolution stage of occluded hydrocarbon of the Lower Cambrian Qiongzhusi Fm in this basin, and 12.3 × 1012 m3 from the source rocks of Sinian Doushantuo Fm, indicating good potential for natural gas resources. It is indicated that the favorable areas of occluded hydrocarbon cracked gas in the Qiongzhusi Fm source rocks in the Sichuan Basin include Gaoshiti–Moxi, Ziyang and Weiyuan, covering a favorable area of 4.3 × 104 km2.

  2. Distribution and Determinants of Myocardial Perfusion Grade Following Late Mechanical Recanalization of Occluded Infarct-Related Arteries Postmyocardial Infarction: A Report From the Occluded Artery Trial

    Science.gov (United States)

    Jorapur, Vinod; Steigen, Terje K.; Buller, Christopher E.; Dẑavík, Vladimír; Webb, John G.; Strauss, Bradley H.; Yeoh, Eunice E.S.; Kurray, Peter; Sokalski, Leszek; Machado, Mauricio C.; Kronsberg, Shari S.; Lamas, Gervasio A.; Hochman, Judith S.; John Mancini, G.B.

    2010-01-01

    Objective To evaluate the distribution and determinants of myocardial perfusion grade (MPG) following late recanalization of persistently occluded infarct-related arteries (IRA). Background MPG reflects microvascular integrity. It is an independent prognostic factor following myocardial infarction, but has been studied mainly in the setting of early reperfusion. The occluded artery trial (OAT) enrolled stable patients with persistently occluded IRAs beyond 24 hr and up to 28 days post-MI. Methods Myocardial blush was assessed using TIMI MPG grading in 261 patients with TIMI 3 epicardial flow following IRA PCI. Patients demonstrating impaired (0–1) versus preserved (2–3) MPG were compared with regard to baseline clinical and pre-PCI angiographic characteristics. Results Impaired MPG was observed in 60 of 261 patients (23%). By univariate analysis, impaired MPG was associated with failed fibrinolytic therapy, higher heart rate, lower systolic blood pressure, lower ejection fraction, LAD occlusion, absence of collaterals (P < 0.01) and ST elevation MI, lower diastolic blood pressure, and higher systolic sphericity index (P < 0.05). By multivariable analysis, higher heart rate, LAD occlusion, absence of collaterals and higher systolic sphericity index (P < 0.01), and lower systolic blood pressure (P < 0.05) were independently associated with impaired MPG. Conclusion Preserved microvascular integrity was present in a high proportion of patients following late recanalization of occluded IRAs post-MI. Presence of collaterals was independently associated with preserved MPG and likely accounted for the high frequency of preserved myocardial perfusion in this clinical setting. Impaired MPG was associated with baseline clinical and angiographic features consistent with larger infarct size. PMID:18798327

  3. Transcatheter closure of ventricular septal defect with Occlutech Duct Occluder.

    Science.gov (United States)

    Atik-Ugan, Sezen; Saltik, Irfan Levent

    2018-04-01

    Patent ductus arteriosus occluders are used for transcatheter closure of ventricular septal defects, as well as for closure of patent ductus arteriosus. The Occlutech Duct Occluder is a newly introduced device for transcatheter closure of patent ductus arteriosus. Here, we present a case in which the Occlutech Duct Occluder was successfully used on a patient for the closure of a perimembraneous ventricular septal defect.

  4. CPDS3, Coupled 3-D Partial Differential Equation Solution

    International Nuclear Information System (INIS)

    Anderson, D.V.; Koniges, A.E.; Shumaker, D.E.

    1992-01-01

    1 - Description of program or function: CPDES3 solves the linear asymmetric matrix equations arising from coupled partial differential equations in three dimensions. The exact form of the matrix depends on the choice of spatial grids and on the finite element or finite difference approximation employed. CPDES3 allows each spatial operator to have 7, 15, 19, or 27 point stencils, permits general couplings between all of the component PDE's, and automatically generates the matrix structures needed to perform the algorithm. 2 - Method of solution: The resulting sparse matrix equation with a complicated sub-band structure and generally asymmetric is solved by either the preconditioned conjugate gradient (CG) method or the preconditioned bi-conjugate gradient (BCG) algorithm. BCG enjoys faster convergence in most cases but in rare instances diverges. Then, CG iterations must be used. 3 - Restrictions on the complexity of the problem: The discretization of the coupled three-dimensional PDE's and their boundary conditions must result in an operator stencil which fits in the Cray2 memory. In addition, the matrix must possess a reasonable amount of diagonal dominance for the preconditioning technique to be effective

  5. Animal experimental research of the endothelialization of home-made atrial septal defect occluder device

    International Nuclear Information System (INIS)

    Chen Mingwu; Zhou Aiqing; Li Feng; Gao Wei; Yu Zhiqing; Tang Ning; Zhang Lan

    2003-01-01

    Objective: To evaluate the endothelialization of Chinese nitinol atrial septal defect occluder device. Methods: Atrial septal defect with controllable size was created by the Brockenborough needle and Rashkind balloon atrial septostomy, the occluder devices were implanted in six piglets (mean weight 7.5 kg). Two pigs were killed each time after 1 month, 3 months and 6 months after the device implantation and then the explanted devices were examined by scanning electron microscope (SEM). Results: The devices were found covering with collagen fibrosis together with diffuse endothelial cells spreading over the primer 1 month after implantation. The implants were covered mostly by neointima 3 months after implantation and completely covered by confluent endothelial cells 6 months after the implantation. Endothelial cells were not found on the smooth marker band at 3 months, however, did exist by 6 months. Conclusions: Home-made atrial septal defect occluder devices were mostly endothelialised 3 months after the implantation and did completely at 6 months

  6. Hemolysis induced by PMIVSD occluder

    Directory of Open Access Journals (Sweden)

    D. Sheshagiri Rao

    2016-09-01

    Full Text Available Hemolysis related to occluder, prosthetic valve, and prosthetic ring used for mitral valve annuloplasty are not very unusual. However, hemolysis related to transcathetor closure of post-myocardial infarction ventricular septal defect (PMIVSD is infrequent. A close follow-up for spontaneous resolution with or without blood transfusion has been reported in a few cases. Occasionally, surgical retrieval is unavoidable or lifelong blood transfusion is required if surgery cannot be done because of higher risk. In this illustration, we have showed a close follow-up of a case of hemolysis induced by atrial septal occluder used for VSD closure after myocardial infarction. Despite successful device closure of PMIVSD which is difficult, a close watch is needed for complications like residual leak, device embolization, and hemolysis.

  7. Experimental nickel elicitation thresholds--a review focusing on occluded nickel exposure

    DEFF Research Database (Denmark)

    Fischer, Louise Arup; Menné, Torkil; Johansen, Jeanne Duus

    2005-01-01

    Nickel (Ni) is the most frequent cause of contact allergy among the female population. This makes it interesting to examine thresholds for elicitation under different conditions. Even though Ni exposure may be open, occluded, penetrating or oral, most dose-response studies in the literature concern...... single occluded application. The aims of this study were to assess thresholds of response by making a statistical analysis of available dose-response studies with single occluded exposure and comparing the results to thresholds from other modes of exposure. 8 occluded Ni dose-response studies were...... 10% reacted in occluded exposure. When combining the exposure to Ni with an irritant, divagating results were found, although the literature shows evidence of an augmented response when combining exposure to an allergen and an irritant. The thresholds of penetrating exposure were found to be lower...

  8. Investigation of stress distribution in normal and oblique partial penetration. Welded nozzles by 3-D photoelastic stress freezing method

    International Nuclear Information System (INIS)

    Miyamoto, H.; Kubo, M.; Katori, T.

    1981-01-01

    Experimental investigation by 3-D photoelasticity has been carried out to measure the stress distribution of partial penetration welded nozzles attached to the bottom head of a pressure vessel. A 3-D photoelastic stress freezing method was chosen as the most effective means of observation of the stress distribution in the vicinity of the nozzle/wall weld. The experimental model was a 1:20 scale spherical bottom head. Both an axisymmetric nozzle and an asymmetric nozzle were investigated. Epoxy resin, which is a thermosetting plastic, was used as the model material. The oblique effect was examined by comparing the stress distribution of the asymmetric nozzle with that of the axisymmetric nozzle. Furthermore, the experimental results were compared with the analytical results using 3-D finite element method (FEM). The stress distributions obtained from the frozen fringe pattern of the 3-D photoelastic model were in good agreement with those by 3-D FEM. (orig.)

  9. Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Park, Michael Y.; Lee, So-Yeon [Seoul St. Mary' s Hospital, The Catholic University of Korea, Department of Radiology, Seoul (Korea, Republic of); Kim, Yang-Soo [Seoul St. Mary' s Hospital, The Catholic University of Korea, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2012-11-15

    To assess the diagnostic performance of shoulder MR arthrography with 3D isotropic fat-suppressed (FS) turbo spin-echo sequence (TSE-SPACE) for supraspinatus tendon tears in comparison with 2D conventional sequences at 3.0 T. The study was HIPAA-compliant and approved by the institutional review board with a waiver of informed consent. Eighty-seven arthroscopically confirmed patients who underwent 3.0 T shoulder MR arthrography with 2D sequences and 3D TSE-SPACE were included in a consecutive fashion from March 2009 to February 2010. Two reviewers independently analyzed 2D sequences and 3D TSE-SPACE. Sensitivity, specificity, accuracy, and interobserver agreement ({kappa}) were compared between 2D sequences and 3D TSE-SPACE for full-thickness and partial-thickness supraspinatus tendon tears together and for partial-thickness supraspinatus tendon tears alone. There were 33 full-thickness tears and 28 partial-thickness tears of supraspinatus tendons. For full-thickness and partial-thickness supraspinatus tendon tears together, the mean sensitivity, specificity, and accuracy of both readers were 96, 92, and 94% on 2D sequences and 91, 84, and 89% on 3D TSE-SPACE. For partial-thickness supraspinatus tendon tears alone, the mean sensitivity, specificity, and accuracy were 95, 92, and 94% on 2D sequences and 84, 85, and 84% on 3D TSE-SPACE. There was no statistical difference between 2D sequences and 3D TSE-SPACE. Interobserver agreements were almost perfect on 2D conventional sequences and substantial on 3D TSE-SPACE. Compared with 2D conventional sequences, MR arthrography using 3D TSE-SPACE was comparable for diagnosing supraspinatus tendon tears despite limitations in detecting small partial-thickness tears and in discriminating between full-thickness and deep partial-thickness tears. (orig.)

  10. Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Park, Michael Y.; Lee, So-Yeon; Kim, Yang-Soo

    2012-01-01

    To assess the diagnostic performance of shoulder MR arthrography with 3D isotropic fat-suppressed (FS) turbo spin-echo sequence (TSE-SPACE) for supraspinatus tendon tears in comparison with 2D conventional sequences at 3.0 T. The study was HIPAA-compliant and approved by the institutional review board with a waiver of informed consent. Eighty-seven arthroscopically confirmed patients who underwent 3.0 T shoulder MR arthrography with 2D sequences and 3D TSE-SPACE were included in a consecutive fashion from March 2009 to February 2010. Two reviewers independently analyzed 2D sequences and 3D TSE-SPACE. Sensitivity, specificity, accuracy, and interobserver agreement (κ) were compared between 2D sequences and 3D TSE-SPACE for full-thickness and partial-thickness supraspinatus tendon tears together and for partial-thickness supraspinatus tendon tears alone. There were 33 full-thickness tears and 28 partial-thickness tears of supraspinatus tendons. For full-thickness and partial-thickness supraspinatus tendon tears together, the mean sensitivity, specificity, and accuracy of both readers were 96, 92, and 94% on 2D sequences and 91, 84, and 89% on 3D TSE-SPACE. For partial-thickness supraspinatus tendon tears alone, the mean sensitivity, specificity, and accuracy were 95, 92, and 94% on 2D sequences and 84, 85, and 84% on 3D TSE-SPACE. There was no statistical difference between 2D sequences and 3D TSE-SPACE. Interobserver agreements were almost perfect on 2D conventional sequences and substantial on 3D TSE-SPACE. Compared with 2D conventional sequences, MR arthrography using 3D TSE-SPACE was comparable for diagnosing supraspinatus tendon tears despite limitations in detecting small partial-thickness tears and in discriminating between full-thickness and deep partial-thickness tears. (orig.)

  11. Closure of the patent ductus arteriosus with the Amplatzer Duct Occluder II: a clinical experience.

    Science.gov (United States)

    Karagöz, Tevfik; Akin, Alper; Ertuğrul, Ilker; Aykan, Hayrettin Hakan; Alehan, Dursun; Ozer, Sema; Ozkutlu, Süheyla

    2012-12-01

    The aim of our study was to share our clinical experience on cases with patent ductus arteriosus treated with the Amplatzer Duct Occluder II. Between 2008 and 2012, 26 of 31 patients with patent ductus arteriosus underwent successful transcatheter closure of patent ductus arteriosus using the Amplatzer Duct Occluder II. Mean age was 3.3 years and mean weight was 15.7 kilograms. The presence of a residual shunt, left pulmonary artery or aortic obstruction was explored by administering contrast material during the procedure. The patients were discharged 24 hours after the procedure. The procedure was successful in 26 of 31 patients and failed in five patients. According to the Krichenko classification, 26 patients had type A, one patient had type B and 4 patients had type C ductus. The mean narrowest ductus diameter was 3.2 mm and the mean ductus length was 6.7 mm. Complete angiographic occlusion occurred immediately after the procedure in 22 out of 26 patients in whom the ductus was closed successfully with the Amplatzer Duct Occluder II. Complete occlusion was achieved in the remaining patients with residual shunt one month after the procedure. The procedure was preceded by closure with an Amplatzer Duct Occluder I in two patients and an Amplatzer Vascular Plug I in one patient. Amplatzer Duct Occluder II is highly effective in transcatheter closure of patent ductus arteriosus. We think that an alternative closure device and alternative techniques can be attempted in patients with type C ductus. The success rate could increase with accumulating experience.

  12. Performance Investigation of a Handheld 3d Scanner to Define Good Practices for Small Artefact 3d Modeling

    Science.gov (United States)

    Lachat, E.; Landes, T.; Grussenmeyer, P.

    2017-08-01

    Handheld 3D scanners can be used to complete large scale models with the acquisition of occluded areas or small artefacts. This may be of interest for digitization projects in the field of Cultural Heritage, where detailed areas may require a specific treatment. Such sensors present the advantage of being easily portable in the field, and easily usable even without particular knowledge. In this paper, the Freestyle3D handheld scanner launched on the market in 2015 by FARO is investigated. Different experiments are described, covering various topics such as the influence of range or color on the measurements, but also the precision achieved for geometrical primitive digitization. These laboratory experiments are completed by acquisitions performed on engraved and sculpted stone blocks. This practical case study is useful to investigate which acquisition protocol seems to be the more adapted and leads to precise results. The produced point clouds will be compared to photogrammetric surveys for the purpose of their accuracy assessment.

  13. Hemolysis induced by PMIVSD occluder.

    Science.gov (United States)

    Rao, D Sheshagiri; Barik, Ramachandra; Siva Prasad, Akula

    2016-09-01

    Hemolysis related to occluder, prosthetic valve, and prosthetic ring used for mitral valve annuloplasty are not very unusual. However, hemolysis related to transcathetor closure of post-myocardial infarction ventricular septal defect (PMIVSD) is infrequent. A close follow-up for spontaneous resolution with or without blood transfusion has been reported in a few cases. Occasionally, surgical retrieval is unavoidable or lifelong blood transfusion is required if surgery cannot be done because of higher risk. In this illustration, we have showed a close follow-up of a case of hemolysis induced by atrial septal occluder used for VSD closure after myocardial infarction. Despite successful device closure of PMIVSD which is difficult, a close watch is needed for complications like residual leak, device embolization, and hemolysis. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  14. Automatic Plant Annotation Using 3D Computer Vision

    DEFF Research Database (Denmark)

    Nielsen, Michael

    In this thesis 3D reconstruction was investigated for application in precision agriculture where previous work focused on low resolution index maps where each pixel represents an area in the field and the index represents an overall crop status in that area. 3D reconstructions of plants would allow...... reconstruction in occluded areas. The trinocular setup was used for both window correlation based and energy minimization based algorithms. A novel adaption of symmetric multiple windows algorithm with trinocular vision was developed. The results were promising and allowed for better disparity estimations...... on steep sloped surfaces. Also, a novel adaption of a well known graph cut based disparity estimation algorithm with trinocular vision was developed and tested. The results were successful and allowed for better disparity estimations on steep sloped surfaces. After finding the disparity maps each...

  15. Generating 3D and 3D-like animations of strongly uneven surface microareas of bloodstains from small series of partially out-of-focus digital SEM micrographs.

    Science.gov (United States)

    Hortolà, Policarp

    2010-01-01

    When dealing with microscopic still images of some kinds of samples, the out-of-focus problem represents a particularly serious limiting factor for the subsequent generation of fully sharp 3D animations. In order to produce fully-focused 3D animations of strongly uneven surface microareas, a vertical stack of six digital secondary-electron SEM micrographs of a human bloodstain microarea was acquired. Afterwards, single combined images were generated using a macrophotography and light microscope image post-processing software. Subsequently, 3D animations of texture and topography were obtained in different formats using a combination of software tools. Finally, a 3D-like animation of a texture-topography composite was obtained in different formats using another combination of software tools. By one hand, results indicate that the use of image post-processing software not concerned primarily with electron micrographs allows to obtain, in an easy way, fully-focused images of strongly uneven surface microareas of bloodstains from small series of partially out-of-focus digital SEM micrographs. On the other hand, results also indicate that such small series of electron micrographs can be utilized for generating 3D and 3D-like animations that can subsequently be converted into different formats, by using certain user-friendly software facilities not originally designed for use in SEM, that are easily available from Internet. Although the focus of this study was on bloodstains, the methods used in it well probably are also of relevance for studying the surface microstructures of other organic or inorganic materials whose sharp displaying is difficult of obtaining from a single SEM micrograph.

  16. The coupled code system TORT-TD/ATTICA3D for 3-D transient analysis of pebble-bed HTGR

    International Nuclear Information System (INIS)

    Seubert, A.; Sureda, A.; Lapins, J.; Buck, M.; Laurien, E.; Bader, J.; EnBW Kernkraft GmbH, Philippsburg

    2012-01-01

    This paper describes the time-dependent 3-D discrete-ordinates based coupled code system TORT-TD/ATTICA3D and its application to HTGR of pebble bed type. TORT-TD/ATTICA3D is represented by a single executable and adapts the so-called internal coupling approach. Three-dimensional distributions of temperatures from ATTICA3D and power density from TORT-TD are efficiently exchanged by direct memory access of array elements via interface routines. Applications of TORT-TD/ATTICA3D to three transients based on the PBMR-400 benchmark (total and partial control rod withdrawal and cold helium ingress) and the full power steady state of the HTR-10 are presented. For the partial control rod withdrawal, 3-D effects of local neutron flux redistributions are clearly identified. The results are very promising and demonstrate that the coupled code system TORT-TD/ATTICA3D may represent a key component in a future comprehensive 3-D code system for HTGR of pebble bed type. (orig.)

  17. Lack of benefit from percutaneous intervention of persistently occluded infarct arteries after the acute phase of myocardial infarction is time independent: insights from Occluded Artery Trial

    Science.gov (United States)

    Menon, Venu; Pearte, Camille A.; Buller, Christopher E.; Steg, Ph.Gabriel; Forman, Sandra A.; White, Harvey D.; Marino, Paolo N.; Katritsis, Demosthenes G.; Caramori, Paulo; Lasevitch, Ricardo; Loboz-Grudzien, Krystyna; Zurakowski, Aleksander; Lamas, Gervasio A.; Hochman, Judith S.

    2009-01-01

    Aims The Occluded Artery Trial (OAT) (n = 2201) showed no benefit for routine percutaneous intervention (PCI) (n = 1101) over medical therapy (MED) (n = 1100) on the combined endpoint of death, myocardial infarction (MI), and class IV heart failure (congestive heart failure) in stable post-MI patients with late occluded infarct-related arteries (IRAs). We evaluated the potential for selective benefit with PCI over MED for patients enrolled early in OAT. Methods and results We explored outcomes with PCI over MED in patients randomized to the ≤3 calendar days and ≤7 calendar days post-MI time windows. Earlier, times to randomization in OAT were associated with higher rates of the combined endpoint (adjusted HR 1.04/day: 99% CI 1.01–1.06; P < 0.001). The 48-month event rates for ≤3 days, ≤7 days post-MI enrolled patients were similar for PCI vs. MED for the combined and individual endpoints. There was no interaction between time to randomization defined as a continuous (P = 0.55) or categorical variable with a cut-point of 3 days (P = 0.98) or 7 days (P = 0.64) post-MI and treatment effect. Conclusion Consistent with overall OAT findings, patients enrolled in the ≤3 day and ≤7 day post-MI time windows derived no benefit with PCI over MED with no interaction between time to randomization and treatment effect. Our findings do not support routine PCI of the occluded IRA in trial-eligible patients even in the earliest 24–72 h time window. PMID:19028780

  18. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  19. 3D Characterization of Recrystallization Boundaries

    DEFF Research Database (Denmark)

    Zhang, Yubin; Godfrey, Andrew William; MacDonald, A. Nicole

    2016-01-01

    A three-dimensional (3D) volume containing a recrystallizing grain and a deformed matrix in a partially recrystallized pure aluminum was characterized using the 3D electron backscattering diffraction technique. The 3D shape of a recrystallizing boundary, separating the recrystallizing grain...... on the formation of protrusions/retrusions....

  20. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results

    Science.gov (United States)

    Sinha, Santosh Kumar; Razi, Mahmadula; Pandey, Rama Niwas; Kumar, Prakash; Krishna, Vinay; Jha, Mukesh Jitendra; Mishra, Vikas; Asif, Mohammad; Abdali, Nasar; Tewari, Pradyot; Thakur, Ramesh; Pandey, Umeshwar; Varma, Chandra Mohan

    2017-01-01

    Objective: To evaluate the feasibility, safety, and efficacy of a novel Cocoon Duct Occluder device for the transcatheter closure (TCC) of large patent ductus arteriosus (PDA). Methods: In this prospective, non-randomized study, consecutive patients with large PDA (narrowest diameter: ≥3.5/4.0 mm in symptomatic/asymptomatic patients, respectively), who underwent TCC with Cocoon Duct Occluder at our institute between November, 2012 and June, 2016 were examined. TCC was performed using the standard technique, and devices were antegradely delivered via 6–10F delivery sheaths. Device embolization, residual shunt, hemolysis, left pulmonary artery (LPA) stenosis, procedural and fluoroscopy time, and mortality were assessed. Patients were followed-up by transthoracic echocardiography with color Doppler imaging at 24 h (D1), 1 month (D30), and 6 months (D180) after implantation. Results: A total of 57 patients (age: 11.7±2.8 years; weight: 22.3±3.5 kg) were enrolled. The mean narrowest diameter was 7.4±0.7 mm. The PDA closure was successfully performed in each patient. Fluoroscopy and procedural time was 6.7±3.2 min and 23.9±2.7 min, respectively. Postprocedural angiography revealed that 49 (85.9%) patients had immediate and complete closure, whereas 8 (14.1%) had residual shunt. Color Doppler imaging at D1 revealed complete closure in 52 (91.3%) patients. At D30, complete closure was reported in all patients and was maintained at D180. Hemolysis, embolization, obstruction of LPA or descending aorta, and death were not reported till D180. Conclusion: TCC using Cocoon Duct Occluder is feasible, safe, and effective in the management of patients with large PDA, with excellent results on short- and medium-term follow-up. PMID:29145233

  1. Densification of salt-occluded zeolite a powders to a leach-resistant monolith

    International Nuclear Information System (INIS)

    Lewis, M.A.; Fischer, D.F.; Murhpy, C.D.

    1993-01-01

    Pyrochemical processing of spent fuel from the Integral Fast Reactor (IFR) yields a salt waste of LiCl-KCl that contains approximately 6 wt% fission products, primarily as CsCl and SrCl 2 . Past work has shown that zeolite A will preferentially sorb cesium and strontium and will encapsulate the salt waste in a leach-resistant, radiation-resistant aluminosilicate matrix. However, a method is sill needed to convert the salt-occluded zeolite powders into a form suitable for geologic disposal. We are thus investigating a method that forms bonded zeolite by hot pressing a mixture of glass frit and salt-occluded zeolite powders at 990 K (717 degree C) and 28 MPa. The leach resistance of the bonded zeolite was measured in static leach tests run for 28 days in 363 K (90 degree C) deionized water. Normalized release rates of all elements in the bonded zeolite were low, 2 d. Thus, the bonded zeolite may be a suitable waste form for IFR salt waste

  2. Cardi-O-Fix duct occluder versus Amplatzer duct occluder for closure of patent ductus arteriosus.

    Science.gov (United States)

    Celebi, Ahmet; Demir, Ibrahim Halil; Saritaş, Türkay; Dedeoğlu, Reyhan; Yucel, Ilker Kemal; Demir, Fadli; Erdem, Abdullah

    2013-11-15

    We sought to investigate the safety, efficacy, and follow-up results of percutaneous patent ductus arteriosus (PDA) closure using the novel Cardi-O-Fix duct occluder (CDO), a device similar to but less expensive than the Amplatzer duct occluder (ADO). We also aimed to compare these two devices in terms of results. Between March 2005 and May 2012, 167 patients diagnosed with moderate-to-large PDA underwent transcatheter closure. ADO was used in 56 (33.5%) patients with a mean age of 8.1 ± 11.9 years (3.6 months-56 years), whereas CDO was used in 111 (66.5%) patients with a mean age of 12.6 ± 14.6 years (4.8 months-63 years). The narrowest PDA diameter, the used device diameter, procedure time, fluoroscopy time, and residual shunt rates were similar between the two groups. Procedural success rate was 100% in both groups. Although the residual shunt rate was higher in the CDO group immediately after the procedure, the difference was not statistically significant (12.6 vs. 8.9%; P = 0.3). There was no statistically significant difference between groups at discharge and during follow-up. No deaths occurred in any of the groups, and there were no differences in complication rates during the short- and mid-term follow-up periods (CDO 7/111 vs. ADO 5/56; P = 0.5 π). The CDO can be used for PDA closure because of its safety, effectiveness, and simplicity in use. It is available in bigger sizes and can be used in patients with large defects. According to our short- and mid-term findings, the results it yields are similar to those of the ADO; thus, it may be the preferred choice owing to its low cost and large size variability. Copyright © 2013 Wiley Periodicals, Inc.

  3. Vitamins D3 and K2 may partially counterbalance the detrimental effects of pentosidine in ex vivo human osteoblasts.

    Science.gov (United States)

    Sanguineti, R; Monacelli, F; Parodi, A; Furfaro, A L; Borghi, R; Pacini, D; Pronzato, M A; Odetti, P; Molfetta, L; Traverso, N

    2016-01-01

    Osteoporosis is a metabolic multifaceted disorder, characterized by insufficient bone strength. It has been recently shown that advanced glycation end products (AGEs) play a role in senile osteoporosis, through bone cell impairment and altered biomechanical properties. Pentosidine (PENT), a wellcharacterized AGE, is also considered a biomarker of bone fracture. Adequate responses to various hormones, such as 1,25-dihydroxyvitamin D 3 , are prerequisites for optimal osteoblasts functioning. Vitamin K 2 is known to enhance in vitro and in vitro vitamin D-induced bone formation. The aim of the study was to assess the effects of Vitamins D 3 and K 2 and PENT on in vitro osteoblast activity, to convey a possible translational clinical message. Ex vivo human osteoblasts cultured, for 3 weeks, with vitamin D 3 and vitamin K 2 were exposed to PENT, a well-known advanced glycoxidation end product for the last 72 hours. Experiments with PENT alone were also carried out. Gene expression of specific markers of bone osteoblast maturation [alkaline phosphatase, ALP; collagen I, COL Iα1; and osteocalcin (bone-Gla-protein) BGP] was measured, together with the receptor activator of nuclear factor kappa-B ligand/osteoproteregin (RANKL/OPG) ratio to assess bone remodeling. Expression of RAGE, a well-characterized receptor of AGEs, was also assessed. PENT+vitamins slightly inhibited ALP secretion while not affecting gene expression, indicating hampered osteoblast functional activity. PENT+vitamins up-regulated collagen gene expression, while protein secretion was unchanged. Intracellular collagen levels were partially decreased, and a significant reduction in BGP gene expression and intracellular protein concentration were both reported after PENT exposure. The RANKL/OPG ratio was increased, favouring bone reabsorption. RAGE gene expression significantly decreased. These results were confirmed by a lower mineralization rate. We provided in vitro evidence that glycoxidation might

  4. Transcatheter closure of secundum atrial septal defect with cardio SEAL septal occluder. A preliminary result of clinical application

    International Nuclear Information System (INIS)

    Zhang Gejun; Dai Ruping; Liu Yanling; Jiang Shiliang; Zeng Zheng; Huang Lianjun; Xie Ruolan

    2001-01-01

    Objective: To evaluate the efficiency and preliminary results of transcatheter closure of secundum atrial septal defect (ASD) with CardioSEAL septal occluder. Methods: There were 12 patients in this study. Trans-esophageal echocardiography (TEE) before the interventions confirmed the ASDs with a mean diameter of *13.14 +- 3.48) mm (ranging from 8 to 20 mm). There were 11 isolated ASDs and 1 multi-defects ASD in the group. Each ASD was occluded with CardioSEAL septal occluder through the percutaneous procedure. The closure procedure was guided by fluoroscopy and trans-esophageal echocardiography. The TEE was done immediately after the procedure to find whether there was residual shunt. Trans-thoracic-echocardiography (TTE), ECG, and X-ray examination were done 24 hours, 1 month, 3 months, and 1 year after the procedures as follow-up to evaluate the efficiency. Results: The placements of the occluders were successful in 11 cases. There were no mortality and no emergent surgery during the procedures. TEE confirmed that there were trivial and small residual shunts in 3 cases immediately after the procedures. TTE confirmed small residual shunts in 2 cases 24 hour after the procedures, and in 1 case 1 month, 3 month, and 1 year after the procedures. Conclusion: Transcatheter closure of secundum ASD with CardioSEAL septal occluder was an efficient nonsurgical method. It could be the method of choice in treating the ASDs with special anatomic variations. It had a high successful rate of device placement and satisfied preliminary results, but the long-term follow-up was needed

  5. Transcatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus.

    Science.gov (United States)

    Wierzyk, Arkadiusz; Szkutnik, Małgorzata; Fiszer, Roland; Banaszak, Paweł; Pawlak, Szymon; Białkowski, Jacek

    2014-01-01

    Ventricular septal defects closure (VSD) depending on the anatomy and clinical setting can be performed surgically or by a hybrid and transcatheter approach. Two cases of children with VSD will be presented. Patients' defects were closed with various types of occluders made of nitinol wire mesh occluder, patent ductus arteriosus (PDA) type. The first case was a 2.5-year-old boy after cardiosurgical correction of tetralogy of Fallot (TOF). After the procedure, a significant haemodynamic residual VSD was observed, which was not successfully closed during the subsequent reoperation. Despite pharmacological treatment, symptoms of heart failure were observed in this patient. In echocardiographic images the residual VSD was presented as a tunnel-like dissection of the ventricular septum (length 6 mm and diameter 3.4 mm). The defect was closed via arterial access with an Amplatzer Duct Occluder II (ADO II). The procedure was successfully performed without any medical complications. In this child, a significant shunt reduction and a noticeable improvement in the patient's clinical status and diminished symptoms of heart failure were noticed. The second patient was a 4-year-old girl suffering from a multi-perforated perimembranous VSD accompanied by a ventricular septal defect with aneurysm. The defect was closed by a venous approach with a PDA Cardio-O-Fix occluder (very similar to ADO I). No short-term or long-term complications were visible during or after the procedure. Only a mild residual shunt through the VSD was observed 6 months afterwards. Transcatheter VSD closure with a proper morphology, with occluders of type Amplatzer Duct Occluder ADO I or ADO II, constitutes a safe and effective therapeutic alternative.

  6. Comparison of factors associated with occludable angle between american Caucasians and ethnic Chinese.

    Science.gov (United States)

    Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan

    2013-11-21

    To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40-80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese.

  7. Insight into the mechanism of methanol assistance with syngas conversion over partially hydroxylated γ-Al2O3(110D) surface in slurry bed.

    Science.gov (United States)

    Bai, Bing; Bai, Hui; Cao, Hao-Jie; Gao, Zhi-Hua; Zuo, Zhi-Jun; Huang, Wei

    2018-04-27

    Despite numerous studies devoted to the various properties of γ-Al2O3, the explorations of its catalytic activity remain scarce. In this study, density functional theory calculations are performed to study the elementary adsorption and reaction mechanisms for syngas conversion on partially hydroxylated γ-Al2O3(110D) surface in liquid paraffin. It is found that the partially hydroxylated γ-Al2O3(110D) surface with the hydroxyl coverage of 8.9 OH nm-2 is formed by two dissociative adsorptions of H2O on the dry γ-Al2O3(110D) surface. The hydroxyl coverage conditions play a key role in determining the dominant reaction mechanism on account of the existence of strong hydrogen bonds. The preferential pathway for syngas conversion with assistance of methanol over the partially hydroxylated γ-Al2O3(110D) surface in liquid paraffin has been proven to be CH3OH → CH3O + H → CH3 + OH, CH3 + CO → CH3CO. C2H5OH is then formed by successive hydrogenation via the pathway CH3CO + 3H → CH3CHO + 2H → CH3CH2O + H → C2H5OH. Here, CH3CHO formation by CH3CO hydrogenation is not inhibited. Actually, with the assistance of partially hydroxylated γ-Al2O3, CH3CHO has been synthesized with high selectivity in our previous experiment by the reaction of methanol and syngas, which provides favorable evidence for our results. The rate-limiting step is the formation of CH3O from CH3OH dehydrogenation with an activation barrier of 122.2 kJ mol-1. Moreover, the reaction barrier of CO insertion into the adsorbed CH3 group is at least 89.4 kJ mol-1, lower than those of CH4, C2H6, and CH3OCH3 formations. ADCH charge and ESP analyses indicate that the typical (Al, O) Lewis acid-base pair may have a significant effect upon the initial C-C chain formation. Thus, the present study provides a new approach for the rational tailoring and designing of new catalysts with superior reactivity involved in syngas conversion.

  8. Transcatheter closure of patent ductus arteriosus using the angled duct occluder

    Energy Technology Data Exchange (ETDEWEB)

    Yongwen, Qin; Xianxian, Zhao; Hong, Wu; Xing, Zheng; Jijun, Ding; Jianqiang, Hu [Second Military Medical Univ., Shanghai (China). Changhai Hospital, Dept. of Cardiology

    2004-04-01

    Objective: To assess the immediate efficacy of transcatheter closure of patent ductus arteriosus(PDA) using the angled duct occluder (ADO). Methods: 9 patients (1 male, 8 female) underwent transcatheter closure of PDA using the ADO. The mean PDA diameter at its narrowest segment was (5.8 {+-} 1.9) mm, ranging 3 to 10 mm. A 6 - 9F long sheath was used for the delivery of ADO. Results: The devices were deployed successfully in all patients. Angiographies showed no shunt across the device 15 min after the implantation of ADO. Within 1 week, echocardiography revealed complete closure in all patients. There were no complications. Conclusions: The transcatheter closure of PDA using ADO is an effective and safe procedure. The device matches with the shape of aortic cavity much more precisely than Amplatzer duct occluder. (authors)

  9. Effects of alkylating agents on dopamine D(3) receptors in rat brain: selective protection by dopamine.

    Science.gov (United States)

    Zhang, K; Weiss, N T; Tarazi, F I; Kula, N S; Baldessarini, R J

    1999-11-13

    Dopamine D(3) receptors are structurally highly homologous to other D(2)-like dopamine receptors, but differ from them pharmacologically. D(3) receptors are notably resistant to alkylation by 1-ethoxycarbonyl-2-ethoxy-1,2-dihydroquinoline (EEDQ), which readily alkylates D(2) receptors. We compared EEDQ with N-(p-isothiocyanatophenethyl)spiperone (NIPS), a selective D(2)-like receptor alkylating agent, for effects on D(3) and D(2) receptors in rat brain using autoradiographic analysis. Neither agent occluded D(3) receptors in vivo at doses that produced substantial blockade of D(2) receptors, even after catecholamine-depleting pretreatments. In vitro, however, D(3) receptors were readily alkylated by both NIPS (IC(50)=40 nM) and EEDQ (IC(50)=12 microM). These effects on D(3) sites were blocked by nM concentrations of dopamine, whereas microM concentrations were required to protect D(2) receptors from the alkylating agents. The findings are consistent with the view that alkylation of D(3) receptors in vivo is prevented by its high affinity for even minor concentrations of endogenous dopamine.

  10. Transcatheter closure of membranous ventricular septal defects with home-made nitinol occluder

    Energy Technology Data Exchange (ETDEWEB)

    Yongwen, Qin; Xianxian, Zhao; Xing, Zheng; Jijun, Ding; Jiang, Cao [Second Military Medical Univ., Shanghai (China). Changhai Hospital, Dept. of Cardiology

    2004-04-01

    Objective: To evaluate the feasibility and efficacy of transcatheter perimembranous ventricular septal defects (VSD) occlusion with home-made nitinol occluder. Methods: Transcatheter closure was attempted in 196 patients with perimembranous VSD. The diameter of VSD measured by echocardiography was 3 to 15 mm, mean (4.94 {+-} 2.23) mm. The angiographic diameter of the VSD was 3 to 6 mm, mean (3.92 {+-} 1.44) mm. A 7-10 F delivery sheath was advanced across the perimembranous VSD over a wire from femoral vein to deploy the occluder with the guidance of echocardiography and fluoroscopy. The device diameter selected was from 4 to 20 mm, mean (6.68 {+-} 2.76) mm. Left ventriculography and transthoracic echocardiography were repeated to assess the closure of the defects 15 min after the procedure. Continuous electrocardiogram monitoring lasted for 5 days. The echocardiography and electrocardiogram examination were scheduled for 1, 6 and 12 months of follow-up. Results: The occluders were successfully deployed in 191 patients. There were five procedural failures, two with device-related aortic insufficiency, and three of inability to pass through VSD. After deployment of the devices, there were no residual shunt in 180 of 191 patients, 11 patients with a trivial residual shunt that disappeared in 8 patients after one month of follow up. 3 patients developed mild tricuspid insufficiency. 12 developed transient complete right bundle branch block, and 5 transient complete left bundle branch block, and 2 transient complete atrioventricular block. There were repetitive nonparoxysmal ventricular tachycardia in 4 patients 1 week after the procedure. One patient had a detached device embolized into the left pulmonary artery but with a successful catheter retrieval by snare and transcatheter closure. The devices were similarly applied to patients with VSD associated with patent ductus arteriosus, and 4 patients with VSD complicated by atrial septal defects. The fluoroscopy time

  11. Cortical dynamics of figure-ground separation in response to 2D pictures and 3D scenes:How V2 combines border ownership, stereoscopic cues, and Gestalt grouping rules

    Directory of Open Access Journals (Sweden)

    Stephen eGrossberg

    2016-01-01

    Full Text Available The FACADE model, and its laminar cortical realization and extension in the 3D LAMINART model, have explained, simulated, and predicted many perceptual and neurobiological data about how the visual cortex carries out 3D vision and figure-ground perception, and how these cortical mechanisms enable 2D pictures to generate 3D percepts of occluding and occluded objects. In particular, these models have proposed how border ownership occurs, but have not yet explicitly explained the correlation between multiple properties of border ownership neurons in cortical area V2 that were reported in a remarkable series of neurophysiological experiments by von der Heydt and his colleagues; namely, border ownership, contrast preference, binocular stereoscopic information, selectivity for side-of-figure, Gestalt rules, and strength of attentional modulation, as well as the time course during which such properties arise. This article shows how, by combining 3D LAMINART properties that were discovered in two parallel streams of research, a unified explanation of these properties emerges. This explanation proposes, moreover, how these properties contribute to the generation of consciously seen 3D surfaces. The first research stream models how processes like 3D boundary grouping and surface filling-in interact in multiple stages within and between the V1 interblob – V2 interstripe – V4 cortical stream and the V1 blob – V2 thin stripe – V4 cortical stream, respectively. Of particular importance for understanding figure-ground separation is how these cortical interactions convert computationally complementary boundary and surface mechanisms into a consistent conscious percept, including the critical use of surface contour feedback signals from surface representations in V2 thin stripes to boundary representations in V2 interstripes. Remarkably, key figure-ground properties emerge from these feedback interactions. The second research stream shows how cells that

  12. Transcatheter closure of patent ductus arteriosus using the angled duct occluder

    International Nuclear Information System (INIS)

    Qin Yongwen; Zhao Xianxian; Wu Hong; Zheng Xing; Ding Jijun; Hu Jianqiang

    2004-01-01

    Objective: To assess the immediate efficacy of transcatheter closure of patent ductus arteriosus(PDA) using the angled duct occluder (ADO). Methods: 9 patients (1 male, 8 female) underwent transcatheter closure of PDA using the ADO. The mean PDA diameter at its narrowest segment was (5.8 ± 1.9) mm, ranging 3 to 10 mm. A 6 - 9F long sheath was used for the delivery of ADO. Results: The devices were deployed successfully in all patients. Angiographies showed no shunt across the device 15 min after the implantation of ADO. Within 1 week, echocardiography revealed complete closure in all patients. There were no complications. Conclusions: The transcatheter closure of PDA using ADO is an effective and safe procedure. The device matches with the shape of aortic cavity much more precisely than Amplatzer duct occluder. (authors)

  13. Pan-nitinol occluder and special delivery device for closure of patent ductus arteriosus: a canine-model feasibility study.

    Science.gov (United States)

    Jiang, Hai-bin; Bai, Yuan; Zong, Gang-jun; Han, Lin; Li, Wei-ping; Lu, Yang; Qin, Yong-wen; Zhao, Xian-xian

    2013-01-01

    The aim of this study was to evaluate a new type of occluder for patent ductus arteriosus. Patent ductus arteriosus was established in a canine model by anastomosing a length of autologous jugular vein to the descending aorta and the left pulmonary artery in an end-to-side fashion. Transcatheter closure of each patent ductus arteriosus was performed on 10 dogs, which were then monitored for as long as 6 months with aortography, echocardiography, and histologic evaluation. Transcatheter closure with use of the novel pan-nitinol device was successful in all canine models. Postoperative echocardiography showed that the location and shape of the occluders were normal, without any residual shunting. Further histologic evaluation confirmed that the occluder surface was completely endothelialized 3 months after implantation. Transcatheter patent ductus arteriosus closure with the pan-nitinol occluder can be performed safely and successfully in a canine model and shows good biological compatibility and low mortality rates.

  14. The clinical application and effect evaluation of home-made duct occluder in patent ductus arteriosus

    Energy Technology Data Exchange (ETDEWEB)

    Jijun, Shi; Guohong, Zeng; Zhiwei, Zhang; Huishen, Wang; Mingyang, Qian; Yufen, Li [Guangdong Provincial People' s Hospital, Guangdong Provincial Cardiovascular Inst., Guangzhou (China)

    2003-08-01

    Objective: To evaluate the clinical application and effect of transcatheter closure of patent ductus arteriosus (PDA) by using the home-made Xinjian duct occluder. Methods: From June, 2000 to July, 2002, 182 patients (63 male, 119 female) underwent attempted transcatheter closure of patent ductus arteriosus by using the Xinjian duct occluder at a median age of 5.23 years (range 0.3 to 16) and a median weight of 17.09 kg (range 5 to 50). The mean PDA diameter in the narrowest segment was 4.30 mm (range 1.32 to 9.00). The delivery sheath was 6 to 10 F. The median operation time was 73.31 min (range 45 to 135), and the median fluoroscopy time was 7.09 min (range 2.60 to 26.90). Follow-up evaluation was performed with color flow mapping immediately, at 24 h, 1 month, 3 months, 6 months, 1 year, and 2 years after closure, respectively. Results: The Xinjian device was successfully placed in all 182 cases. Angiography showed immediate closure in 109 patients (59.89%), small residual shunt in 30, and trace shunt in 43. At 24 h, color Doppler revealed complete closure in 163 patients. Only 8 patients still had a residual shunt after 1 month. A residual shunt was observed in 4 at 3 months and 6 months, 2 at 1 year, 1 at 2 years. There were no severe complications. Conclusions: Transcatheter closure of PDA using the home-made Xinjian occluder is a safe and effective method. The Xinjian occluder could replace the imported product in the closure of PDA.

  15. The clinical application and effect evaluation of home-made duct occluder in patent ductus arteriosus

    International Nuclear Information System (INIS)

    Shi Jijun; Zeng Guohong; Zhang Zhiwei; Wang Huishen; Qian Mingyang; Li Yufen

    2003-01-01

    Objective: To evaluate the clinical application and effect of transcatheter closure of patent ductus arteriosus (PDA) by using the home-made Xinjian duct occluder. Methods: From June, 2000 to July, 2002, 182 patients (63 male, 119 female) underwent attempted transcatheter closure of patent ductus arteriosus by using the Xinjian duct occluder at a median age of 5.23 years (range 0.3 to 16) and a median weight of 17.09 kg (range 5 to 50). The mean PDA diameter in the narrowest segment was 4.30 mm (range 1.32 to 9.00). The delivery sheath was 6 to 10 F. The median operation time was 73.31 min (range 45 to 135), and the median fluoroscopy time was 7.09 min (range 2.60 to 26.90). Follow-up evaluation was performed with color flow mapping immediately, at 24 h, 1 month, 3 months, 6 months, 1 year, and 2 years after closure, respectively. Results: The Xinjian device was successfully placed in all 182 cases. Angiography showed immediate closure in 109 patients (59.89%), small residual shunt in 30, and trace shunt in 43. At 24 h, color Doppler revealed complete closure in 163 patients. Only 8 patients still had a residual shunt after 1 month. A residual shunt was observed in 4 at 3 months and 6 months, 2 at 1 year, 1 at 2 years. There were no severe complications. Conclusions: Transcatheter closure of PDA using the home-made Xinjian occluder is a safe and effective method. The Xinjian occluder could replace the imported product in the closure of PDA

  16. Partially Loaded Cavity Analysis by Using the 2-D FDTD Method

    International Nuclear Information System (INIS)

    Yao Bin; Zheng Qin-Hong; Peng Jin-Hui; Zhong Ru-Neng; Xiang Tai; Xu Wan-Song

    2011-01-01

    A compact two-dimensional (2-D) finite-difference time-domain (FDTD) method is proposed to calculate the resonant frequencies and quality factors of a partially loaded cavity that is uniform in the z-direction and has an arbitrary cross section in the x—y plane. With the description of z dependence by k z , the three-dimensional (3-D) problem can be transformed into a 2-D problem. Therefore, less memory and CPU time are required as compared to the conventional 3-D FDTD method. Three representative examples, a half-loaded rectangular cavity, an inhomogeneous cylindrical cavity and a cubic cavity loaded with dielectric post, are presented to validate the utility and efficiency of the proposed method. (cross-disciplinary physics and related areas of science and technology)

  17. Identification and characterization of steady and occluded water in drinking water distribution systems.

    Science.gov (United States)

    Tong, Huiyan; Zhao, Peng; Zhang, Hongwei; Tian, Yimei; Chen, Xi; Zhao, Weigao; Li, Mei

    2015-01-01

    Deterioration and leakage of drinking water in distribution systems have been a major issue in the water industry for years, which are associated with corrosion. This paper discovers that occluded water in the scales of the pipes has an acidic environment and high concentration of iron, manganese, chloride, sulfate and nitrate, which aggravates many pipeline leakage accidents. Six types of water samples have been analyzed under the flowing and stagnant periods. Both the water in the exterior of the tubercles and stagnant water carry suspended iron particles, which explains the occurrence of "red water" when the system hydraulic conditions change. Nitrate is more concentrated in occluded water under flowing condition in comparison with that in flowing water. However, the concentration of nitrate in occluded water under stagnant condition is found to be less than that in stagnant water. A high concentration of manganese is found to exist in steady water, occluded water and stagnant water. These findings impact secondary pollution and the corrosion of pipes and containers used in drinking water distribution systems. The unique method that taking occluded water from tiny holes which were drilled from the pipes' exteriors carefully according to the positions of corrosion scales has an important contribution to research on corrosion in distribution systems. And this paper furthers our understanding and contributes to the growing body of knowledge regarding occluded environments in corrosion scales. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Magnetic targeting to enhance microbubble delivery in an occluded microarterial bifurcation.

    Science.gov (United States)

    de Saint Victor, M; Carugo, D; Barnsley, L C; Owen, J; Coussios, C-C; Stride, E

    2017-09-05

    Ultrasound and microbubbles have been shown to accelerate the breakdown of blood clots both in vitro and in vivo. Clinical translation of this technology is still limited, however, in part by inefficient microbubble delivery to the thrombus. This study examines the obstacles to delivery posed by fluid dynamic conditions in occluded vasculature and investigates whether magnetic targeting can improve microbubble delivery. A 2D computational fluid dynamic model of a fully occluded Y-shaped microarterial bifurcation was developed to determine: (i) the fluid dynamic field in the vessel with inlet velocities from 1-100 mm s -1 (corresponding to Reynolds numbers 0.25-25); (ii) the transport dynamics of fibrinolytic drugs; and (iii) the flow behavior of microbubbles with diameters in the clinically-relevant range (0.6-5 µm). In vitro experiments were carried out in a custom-built microfluidic device. The flow field was characterized using tracer particles, and fibrinolytic drug transport was assessed using fluorescence microscopy. Lipid-shelled magnetic microbubbles were fluorescently labelled to determine their spatial distribution within the microvascular model. In both the simulations and experiments, the formation of laminar vortices and an abrupt reduction of fluid velocity were observed in the occluded branch of the bifurcation, severely limiting drug transport towards the occlusion. In the absence of a magnetic field, no microbubbles reached the occlusion, remaining trapped in the first vortex, within 350 µm from the bifurcation center. The number of microbubbles trapped within the vortex decreased as the inlet velocity increased, but was independent of microbubble size. Application of a magnetic field (magnetic flux density of 76 mT, magnetic flux density gradient of 10.90 T m -1 at the centre of the bifurcation) enabled delivery of microbubbles to the occlusion and the number of microbubbles delivered increased with bubble size and with decreasing inlet

  19. 3D early embryogenesis image filtering by nonlinear partial differential equations.

    Science.gov (United States)

    Krivá, Z; Mikula, K; Peyriéras, N; Rizzi, B; Sarti, A; Stasová, O

    2010-08-01

    We present nonlinear diffusion equations, numerical schemes to solve them and their application for filtering 3D images obtained from laser scanning microscopy (LSM) of living zebrafish embryos, with a goal to identify the optimal filtering method and its parameters. In the large scale applications dealing with analysis of 3D+time embryogenesis images, an important objective is a correct detection of the number and position of cell nuclei yielding the spatio-temporal cell lineage tree of embryogenesis. The filtering is the first and necessary step of the image analysis chain and must lead to correct results, removing the noise, sharpening the nuclei edges and correcting the acquisition errors related to spuriously connected subregions. In this paper we study such properties for the regularized Perona-Malik model and for the generalized mean curvature flow equations in the level-set formulation. A comparison with other nonlinear diffusion filters, like tensor anisotropic diffusion and Beltrami flow, is also included. All numerical schemes are based on the same discretization principles, i.e. finite volume method in space and semi-implicit scheme in time, for solving nonlinear partial differential equations. These numerical schemes are unconditionally stable, fast and naturally parallelizable. The filtering results are evaluated and compared first using the Mean Hausdorff distance between a gold standard and different isosurfaces of original and filtered data. Then, the number of isosurface connected components in a region of interest (ROI) detected in original and after the filtering is compared with the corresponding correct number of nuclei in the gold standard. Such analysis proves the robustness and reliability of the edge preserving nonlinear diffusion filtering for this type of data and lead to finding the optimal filtering parameters for the studied models and numerical schemes. Further comparisons consist in ability of splitting the very close objects which

  20. Intra-arterial high signals on arterial spin labeling perfusion images predict the occluded internal carotid artery segment

    International Nuclear Information System (INIS)

    Sogabe, Shu; Satomi, Junichiro; Tada, Yoshiteru; Kanematsu, Yasuhisa; Kuwayama, Kazuyuki; Yagi, Kenji; Yoshioka, Shotaro; Mizobuchi, Yoshifumi; Mure, Hideo; Yamaguchi, Izumi; Kitazato, Keiko T.; Nagahiro, Shinji; Abe, Takashi; Harada, Masafumi; Yamamoto, Nobuaki; Kaji, Ryuji

    2017-01-01

    Arterial spin labeling (ASL) involves perfusion imaging using the inverted magnetization of arterial water. If the arterial arrival times are longer than the post-labeling delay, labeled spins are visible on ASL images as bright, high intra-arterial signals (IASs); such signals were found within occluded vessels of patients with acute ischemic stroke. The identification of the occluded segment in the internal carotid artery (ICA) is crucial for endovascular treatment. We tested our hypothesis that high IASs on ASL images can predict the occluded segment. Our study included 13 patients with acute ICA occlusion who had undergone angiographic and ASL studies within 48 h of onset. We retrospectively identified the high IAS on ASL images and angiograms and recorded the occluded segment and the number of high IAS-positive slices on ASL images. The ICA segments were classified as cervical (C1), petrous (C2), cavernous (C3), and supraclinoid (C4). Of seven patients with intracranial ICA occlusion, five demonstrated high IASs at C1-C2, suggesting that high IASs could identify stagnant flow proximal to the occluded segment. Among six patients with extracranial ICA occlusion, five presented with high IASs at C3-C4, suggesting that signals could identify the collateral flow via the ophthalmic artery. None had high IASs at C1-C2. The mean number of high IAS-positive slices was significantly higher in patients with intra- than extracranial ICA occlusion. High IASs on ASL images can identify slow stagnant and collateral flow through the ophthalmic artery in patients with acute ICA occlusion and help to predict the occlusion site. (orig.)

  1. Intra-arterial high signals on arterial spin labeling perfusion images predict the occluded internal carotid artery segment

    Energy Technology Data Exchange (ETDEWEB)

    Sogabe, Shu; Satomi, Junichiro; Tada, Yoshiteru; Kanematsu, Yasuhisa; Kuwayama, Kazuyuki; Yagi, Kenji; Yoshioka, Shotaro; Mizobuchi, Yoshifumi; Mure, Hideo; Yamaguchi, Izumi; Kitazato, Keiko T.; Nagahiro, Shinji [Tokushima University Graduate School, Department of Neurosurgery, Tokushima (Japan); Abe, Takashi; Harada, Masafumi [Tokushima University Graduate School, Department of Radiology, Tokushima (Japan); Yamamoto, Nobuaki; Kaji, Ryuji [Tokushima University Graduate School, Department of Clinical Neurosciences, Institute of Biomedical Biosciences, Tokushima (Japan)

    2017-06-15

    Arterial spin labeling (ASL) involves perfusion imaging using the inverted magnetization of arterial water. If the arterial arrival times are longer than the post-labeling delay, labeled spins are visible on ASL images as bright, high intra-arterial signals (IASs); such signals were found within occluded vessels of patients with acute ischemic stroke. The identification of the occluded segment in the internal carotid artery (ICA) is crucial for endovascular treatment. We tested our hypothesis that high IASs on ASL images can predict the occluded segment. Our study included 13 patients with acute ICA occlusion who had undergone angiographic and ASL studies within 48 h of onset. We retrospectively identified the high IAS on ASL images and angiograms and recorded the occluded segment and the number of high IAS-positive slices on ASL images. The ICA segments were classified as cervical (C1), petrous (C2), cavernous (C3), and supraclinoid (C4). Of seven patients with intracranial ICA occlusion, five demonstrated high IASs at C1-C2, suggesting that high IASs could identify stagnant flow proximal to the occluded segment. Among six patients with extracranial ICA occlusion, five presented with high IASs at C3-C4, suggesting that signals could identify the collateral flow via the ophthalmic artery. None had high IASs at C1-C2. The mean number of high IAS-positive slices was significantly higher in patients with intra- than extracranial ICA occlusion. High IASs on ASL images can identify slow stagnant and collateral flow through the ophthalmic artery in patients with acute ICA occlusion and help to predict the occlusion site. (orig.)

  2. Time course of spatial and feature selective attention for partly-occluded objects.

    Science.gov (United States)

    Kasai, Tetsuko; Takeya, Ryuji

    2012-07-01

    Attention selects objects/groups as the most fundamental units, and this may be achieved by an attention-spreading mechanism. Previous event-related potential (ERP) studies have found that attention-spreading is reflected by a decrease in the N1 spatial attention effect. The present study tested whether the electrophysiological attention effect is associated with the perception of object unity or amodal completion through the use of partly-occluded objects. ERPs were recorded in 14 participants who were required to pay attention to their left or right visual field and to press a button for a target shape in the attended field. Bilateral stimuli were presented rapidly, and were separated, connected, or connected behind an occluder. Behavioral performance in the connected and occluded conditions was worse than that in the separated condition, indicating that attention spread over perceptual object representations after amodal completion. Consistently, the late N1 spatial attention effect (180-220 ms post-stimulus) and the early phase (230-280 ms) of feature selection effects (target N2) at contralateral sites decreased, equally for the occluded and connected conditions, while the attention effect in the early N1 latency (140-180 ms) shifted most positively for the occluded condition. These results suggest that perceptual organization processes for object recognition transiently modulate spatial and feature selection processes in the visual cortex. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. A FAST METHOD FOR MEASURING THE SIMILARITY BETWEEN 3D MODEL AND 3D POINT CLOUD

    Directory of Open Access Journals (Sweden)

    Z. Zhang

    2016-06-01

    Full Text Available This paper proposes a fast method for measuring the partial Similarity between 3D Model and 3D point Cloud (SimMC. It is crucial to measure SimMC for many point cloud-related applications such as 3D object retrieval and inverse procedural modelling. In our proposed method, the surface area of model and the Distance from Model to point Cloud (DistMC are exploited as measurements to calculate SimMC. Here, DistMC is defined as the weighted distance of the distances between points sampled from model and point cloud. Similarly, Distance from point Cloud to Model (DistCM is defined as the average distance of the distances between points in point cloud and model. In order to reduce huge computational burdens brought by calculation of DistCM in some traditional methods, we define SimMC as the ratio of weighted surface area of model to DistMC. Compared to those traditional SimMC measuring methods that are only able to measure global similarity, our method is capable of measuring partial similarity by employing distance-weighted strategy. Moreover, our method is able to be faster than other partial similarity assessment methods. We demonstrate the superiority of our method both on synthetic data and laser scanning data.

  4. Cortical Dynamics of Figure-Ground Separation in Response to 2D Pictures and 3D Scenes: How V2 Combines Border Ownership, Stereoscopic Cues, and Gestalt Grouping Rules

    Science.gov (United States)

    Grossberg, Stephen

    2016-01-01

    The FACADE model, and its laminar cortical realization and extension in the 3D LAMINART model, have explained, simulated, and predicted many perceptual and neurobiological data about how the visual cortex carries out 3D vision and figure-ground perception, and how these cortical mechanisms enable 2D pictures to generate 3D percepts of occluding and occluded objects. In particular, these models have proposed how border ownership occurs, but have not yet explicitly explained the correlation between multiple properties of border ownership neurons in cortical area V2 that were reported in a remarkable series of neurophysiological experiments by von der Heydt and his colleagues; namely, border ownership, contrast preference, binocular stereoscopic information, selectivity for side-of-figure, Gestalt rules, and strength of attentional modulation, as well as the time course during which such properties arise. This article shows how, by combining 3D LAMINART properties that were discovered in two parallel streams of research, a unified explanation of these properties emerges. This explanation proposes, moreover, how these properties contribute to the generation of consciously seen 3D surfaces. The first research stream models how processes like 3D boundary grouping and surface filling-in interact in multiple stages within and between the V1 interblob—V2 interstripe—V4 cortical stream and the V1 blob—V2 thin stripe—V4 cortical stream, respectively. Of particular importance for understanding figure-ground separation is how these cortical interactions convert computationally complementary boundary and surface mechanisms into a consistent conscious percept, including the critical use of surface contour feedback signals from surface representations in V2 thin stripes to boundary representations in V2 interstripes. Remarkably, key figure-ground properties emerge from these feedback interactions. The second research stream shows how cells that compute absolute disparity

  5. Cortical Dynamics of Figure-Ground Separation in Response to 2D Pictures and 3D Scenes: How V2 Combines Border Ownership, Stereoscopic Cues, and Gestalt Grouping Rules.

    Science.gov (United States)

    Grossberg, Stephen

    2015-01-01

    The FACADE model, and its laminar cortical realization and extension in the 3D LAMINART model, have explained, simulated, and predicted many perceptual and neurobiological data about how the visual cortex carries out 3D vision and figure-ground perception, and how these cortical mechanisms enable 2D pictures to generate 3D percepts of occluding and occluded objects. In particular, these models have proposed how border ownership occurs, but have not yet explicitly explained the correlation between multiple properties of border ownership neurons in cortical area V2 that were reported in a remarkable series of neurophysiological experiments by von der Heydt and his colleagues; namely, border ownership, contrast preference, binocular stereoscopic information, selectivity for side-of-figure, Gestalt rules, and strength of attentional modulation, as well as the time course during which such properties arise. This article shows how, by combining 3D LAMINART properties that were discovered in two parallel streams of research, a unified explanation of these properties emerges. This explanation proposes, moreover, how these properties contribute to the generation of consciously seen 3D surfaces. The first research stream models how processes like 3D boundary grouping and surface filling-in interact in multiple stages within and between the V1 interblob-V2 interstripe-V4 cortical stream and the V1 blob-V2 thin stripe-V4 cortical stream, respectively. Of particular importance for understanding figure-ground separation is how these cortical interactions convert computationally complementary boundary and surface mechanisms into a consistent conscious percept, including the critical use of surface contour feedback signals from surface representations in V2 thin stripes to boundary representations in V2 interstripes. Remarkably, key figure-ground properties emerge from these feedback interactions. The second research stream shows how cells that compute absolute disparity in

  6. Transcatheter closure of membranous ventricular septal defects with home-made nitinol occluder

    International Nuclear Information System (INIS)

    Qin Yongwen; Zhao Xianxian; Zheng Xing; Ding Jijun; Cao Jiang

    2004-01-01

    Objective: To evaluate the feasibility and efficacy of transcatheter perimembranous ventricular septal defects (VSD) occlusion with home-made nitinol occluder. Methods: Transcatheter closure was attempted in 196 patients with perimembranous VSD. The diameter of VSD measured by echocardiography was 3 to 15 mm, mean (4.94 ± 2.23) mm. The angiographic diameter of the VSD was 3 to 6 mm, mean (3.92 ± 1.44) mm. A 7-10 F delivery sheath was advanced across the perimembranous VSD over a wire from femoral vein to deploy the occluder with the guidance of echocardiography and fluoroscopy. The device diameter selected was from 4 to 20 mm, mean (6.68 ± 2.76) mm. Left ventriculography and transthoracic echocardiography were repeated to assess the closure of the defects 15 min after the procedure. Continuous electrocardiogram monitoring lasted for 5 days. The echocardiography and electrocardiogram examination were scheduled for 1, 6 and 12 months of follow-up. Results: The occluders were successfully deployed in 191 patients. There were five procedural failures, two with device-related aortic insufficiency, and three of inability to pass through VSD. After deployment of the devices, there were no residual shunt in 180 of 191 patients, 11 patients with a trivial residual shunt that disappeared in 8 patients after one month of follow up. 3 patients developed mild tricuspid insufficiency. 12 developed transient complete right bundle branch block, and 5 transient complete left bundle branch block, and 2 transient complete atrioventricular block. There were repetitive nonparoxysmal ventricular tachycardia in 4 patients 1 week after the procedure. One patient had a detached device embolized into the left pulmonary artery but with a successful catheter retrieval by snare and transcatheter closure. The devices were similarly applied to patients with VSD associated with patent ductus arteriosus, and 4 patients with VSD complicated by atrial septal defects. The fluoroscopy time for the

  7. Electronic eye occluder with time-counting and reflection control

    Science.gov (United States)

    Karitans, V.; Ozolinsh, M.; Kuprisha, G.

    2008-09-01

    In pediatric ophthalmology 2 - 3 % of all the children are impacted by a visual pathology - amblyopia. It develops if a clear image isn't presented to the retina during an early stage of the development of the visual system. A common way of treating this pathology is to cover the better-seeing eye to force the "lazy" eye to learn seeing. However, children are often reluctant to wear such an occluder because they are ashamed or simply because they find it inconvenient. This fact requires to find a way how to track the regime of occlusion because results of occlusion is a hint that the actual regime of occlusion isn't that what the optometrist has recommended. We design an electronic eye occluder that allows to track the regime of eye occlusion. We employ real-time clock DS1302 providing time information from seconds to years. Data is stored in the internal memory of the CPU (EEPROM). The MCU (PIC16F676) switches on only if a mechanical switch is closed and temperature has reached a satisfactory level. The occlusion is registered between time moments when the infrared signal appeared and disappeared.

  8. The exploration of the closure of patent ductus arteriosus with Amplatzer occluder through single venous approach under ultrasound monitoring

    International Nuclear Information System (INIS)

    Luo Guoxin; He Jianxin; Li Guoying; Gong Zhihua; Wen Yanfei

    2011-01-01

    Objective: To explore the feasibility and effectiveness of transcatheter closure of patent ductus arteriosus (PDA) with Amplatzer occluder by using single venous approach method under ultrasound monitoring. Methods: During the period from May 2003 to April 2010, transcatheter closure of PDA were performed in 123 cases. Of the 123 patients, the procedure was accomplished by using arteriovenous dual approach method in 46 and by using single venous approach method in 77. All the procedures were monitored by ultrasound. The shape, size of PDA and immediate therapeutic results were checked with angiography in arteriovenous dual approach method or with ultrasonography in single venous approach method. The size of Amplatzer occluder was individually selected according to the smallest diameter of PDA. Echocardiography was performed at 3 days, one, 6 and 12 months after the procedure to evaluate the results. Results: Successful device placement with the initially selected occluder was obtained in 118 cases. In 4 cases the procedure was eventually completed after a bigger occluder was employed to replace the initial one, while in one case a smaller occluder had to use to replace the first one. The technical success rate was 100%. Conclusion: The transcatheter closure of PDA with Amplatzer occluder under ultrasound monitoring by single venous approach method is clinically effective and feasible. Being technically simple and time-saving, this single venous approach method is of great value in clinical practice. (authors)

  9. Transcaval TIPS in patients with failed revision of occluded previous TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Chang Kyu; Kim, Yong Joo; Shin, Tae Beom; Park, Hyo Yong; Kim, Tae Hun; Kang, Duk Sik [Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2001-12-01

    To determine the feasibility of transcaval transjugular intrahepatic portosystemic shunt (TIPS) in patients with occluded previous TIPS. Between February 1996 and December 2000 we performed five transcaval TIPS procedures in four patients with recurrent gastric cardiac variceal bleeding. All four had occluded TIPS, which was between the hepatic and portal vein. The interval between initial TIPS placement and revisional procedures with transcaval TIPS varied between three and 31 months; one patient underwent transcaval TIPS twice, with a 31-month interval. After revision of the occluded shunt failed, direct cavoportal puncture at the retrohepatic segment of the IVC was attempted. Transcaval TIPS placement was technically successful in all cases. In three, tractography revealed slight leakage of contrast materials into hepatic subcapsular or subdiaphragmatic pericaval space. There was no evidence of propagation of extravasated contrast materials through the retroperitoneal space or spillage into the peritoneal space. After the tract was dilated by a bare stent, no patient experienced trans-stent bleeding and no serious procedure-related complications occurred. After successful shunt creation, variceal bleeding ceased in all patients. Transcaval TIPS placement is an effective and safe alternative treatment in patients with occluded previous TIPS and no hepatic veins suitable for new TIPS.

  10. Reconocimiento facial combinando técnicas 2D y 3D

    OpenAIRE

    González Ferreiro, Montserrat

    2007-01-01

    El propósito del proyecto es permitir combinar imágenes 3D y 2D para realizar un reconocimiento facial automático. Para ello se procesarán las imágenes 3D de profundidad sin textura de la base de datos GavabDB para posteriormente utilizarlas como imágenes de entrenamiento en un sistema de reconocimiento facial que emplee el algoritmo de P2CA (Partial Principal Components Analysis). Las imágenes 3D se procesarán, mediante unos editores programados en Matlab, de manera que fin...

  11. Automatic extraction of Manhattan-World building masses from 3D laser range scans.

    Science.gov (United States)

    Vanegas, Carlos A; Aliaga, Daniel G; Benes, Bedrich

    2012-10-01

    We propose a novel approach for the reconstruction of urban structures from 3D point clouds with an assumption of Manhattan World (MW) building geometry; i.e., the predominance of three mutually orthogonal directions in the scene. Our approach works in two steps. First, the input points are classified according to the MW assumption into four local shape types: walls, edges, corners, and edge corners. The classified points are organized into a connected set of clusters from which a volume description is extracted. The MW assumption allows us to robustly identify the fundamental shape types, describe the volumes within the bounding box, and reconstruct visible and occluded parts of the sampled structure. We show results of our reconstruction that has been applied to several synthetic and real-world 3D point data sets of various densities and from multiple viewpoints. Our method automatically reconstructs 3D building models from up to 10 million points in 10 to 60 seconds.

  12. Subintimal Recanalization of Occluded Stents: The Substent Technique

    International Nuclear Information System (INIS)

    Diamantopoulos, Athanasios; Katsanos, Konstantinos; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris

    2013-01-01

    PurposeApplication of metal stents is complicated by neointimal hyperplasia leading to vessel restenosis and reocclusion. Treatment options in cases presenting with complete occlusion of the stented segment and recurrent critical limb ischemia (CLI) are limited. We present the option of the subintimal/substent technique in dealing with occluded stents.MethodsThe study included patients presenting with recurrent CLI due to impaired blood flow as a result of complete occlusion of previously inserted metal stents and unsuccessful intraluminal crossing of the lesion via either the antegrade or retrograde approach. In these cases, crossing the occlusion through the subintimal/substent plane was attempted. Primary end points included technical success, safety of the procedure, clinical improvement, and limb salvage, while secondary end points were patient survival, primary patency, and vessel restenosis rates at 1-year follow-up. Study end points were calculated by Kaplan–Meier survival analysis.ResultsBetween July 2006 and October 2011, a total of 14 patients (mean age 69.14 ± 12.59 years, 12 men) were treated with the substent technique and included in the analysis. Technical success rate was 85.71 % (12 of 14), with a total lesion length of 193.57 ± 90.78 mm. The mean occluded stented segment length was 90.21 ± 44.34 mm. In 10 (83.33 %) of 12 cases, a new stent had to be placed by the side of the old occluded one, while the remaining two cases (16.67 %) were treated only with balloon angioplasty. No serious adverse events were noted during the immediate postprocedural period. All successfully treated patients improved clinically. Estimated limb salvage was 90.9 %, and patient survival rate was 90.0 % at 1 year’s follow-up. Primary patency was 45.50 % and vessel restenosis 77.30 %.ConclusionSubintimal recanalization of occluded metal stents through the substent plane is a valuable alternative treatment option, especially in patients with recurrent CLI with few

  13. Towards a universal method for calculating hydration free energies: a 3D reference interaction site model with partial molar volume correction

    International Nuclear Information System (INIS)

    Palmer, David S; Frolov, Andrey I; Ratkova, Ekaterina L; Fedorov, Maxim V

    2010-01-01

    We report a simple universal method to systematically improve the accuracy of hydration free energies calculated using an integral equation theory of molecular liquids, the 3D reference interaction site model. A strong linear correlation is observed between the difference of the experimental and (uncorrected) calculated hydration free energies and the calculated partial molar volume for a data set of 185 neutral organic molecules from different chemical classes. By using the partial molar volume as a linear empirical correction to the calculated hydration free energy, we obtain predictions of hydration free energies in excellent agreement with experiment (R = 0.94, σ = 0.99 kcal mol -1 for a test set of 120 organic molecules). (fast track communication)

  14. Towards a universal method for calculating hydration free energies: a 3D reference interaction site model with partial molar volume correction.

    Science.gov (United States)

    Palmer, David S; Frolov, Andrey I; Ratkova, Ekaterina L; Fedorov, Maxim V

    2010-12-15

    We report a simple universal method to systematically improve the accuracy of hydration free energies calculated using an integral equation theory of molecular liquids, the 3D reference interaction site model. A strong linear correlation is observed between the difference of the experimental and (uncorrected) calculated hydration free energies and the calculated partial molar volume for a data set of 185 neutral organic molecules from different chemical classes. By using the partial molar volume as a linear empirical correction to the calculated hydration free energy, we obtain predictions of hydration free energies in excellent agreement with experiment (R = 0.94, σ = 0.99 kcal mol (- 1) for a test set of 120 organic molecules).

  15. Octanol-Water Partition Coefficient from 3D-RISM-KH Molecular Theory of Solvation with Partial Molar Volume Correction.

    Science.gov (United States)

    Huang, WenJuan; Blinov, Nikolay; Kovalenko, Andriy

    2015-04-30

    The octanol-water partition coefficient is an important physical-chemical characteristic widely used to describe hydrophobic/hydrophilic properties of chemical compounds. The partition coefficient is related to the transfer free energy of a compound from water to octanol. Here, we introduce a new protocol for prediction of the partition coefficient based on the statistical-mechanical, 3D-RISM-KH molecular theory of solvation. It was shown recently that with the compound-solvent correlation functions obtained from the 3D-RISM-KH molecular theory of solvation, the free energy functional supplemented with the correction linearly related to the partial molar volume obtained from the Kirkwood-Buff/3D-RISM theory, also called the "universal correction" (UC), provides accurate prediction of the hydration free energy of small compounds, compared to explicit solvent molecular dynamics [ Palmer , D. S. ; J. Phys.: Condens. Matter 2010 , 22 , 492101 ]. Here we report that with the UC reparametrized accordingly this theory also provides an excellent agreement with the experimental data for the solvation free energy in nonpolar solvent (1-octanol) and so accurately predicts the octanol-water partition coefficient. The performance of the Kovalenko-Hirata (KH) and Gaussian fluctuation (GF) functionals of the solvation free energy, with and without UC, is tested on a large library of small compounds with diverse functional groups. The best agreement with the experimental data for octanol-water partition coefficients is obtained with the KH-UC solvation free energy functional.

  16. Face Attention Network: An Effective Face Detector for the Occluded Faces

    OpenAIRE

    Wang, Jianfeng; Yuan, Ye; Yu, Gang

    2017-01-01

    The performance of face detection has been largely improved with the development of convolutional neural network. However, the occlusion issue due to mask and sunglasses, is still a challenging problem. The improvement on the recall of these occluded cases usually brings the risk of high false positives. In this paper, we present a novel face detector called Face Attention Network (FAN), which can significantly improve the recall of the face detection problem in the occluded case without comp...

  17. Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo

    International Nuclear Information System (INIS)

    Zhang, Zhi xiong; Fu, Bu fang; Zhang, De yuan; Zhang, Zhi wei; Cheng, Yan; Sheng, Li yuan; Lai, Chen; Xi, Ting fei

    2013-01-01

    Atrial septal defect (ASD) occlusion devices made of nickel–titanium (NiTi) have a major shortcoming in that they release nickel into the body. We modified NiTi occluders using Arc Ion Plating technology. Nano lamellar titanium–nitrogen (TiN) coatings were formed on the surfaces of the occluders. The safety and efficacy of the modified NiTi occluders were evaluated in animal model. The results showed that 38 out of 39 rams (97%) survived at the end of the experiment. Fibrous capsules formed on the surfaces of the devices. Gradual endothelialization took place through the attachment of endothelial progenitor cells from the blood and the migration of endothelial cells from adjacent endocardium. The neo-endocardium formed more quickly in the coated group than in the uncoated group, as indicated by the evaluation of the six month study group. After TiN coating, there was no significant difference in endothelial cell cycle. TiN coating significantly reduced the release of nickel in both in vivo and in vitro indicating an improved biocompatibility of the nitinol ASD occluders. Superior and modified ASD occluders may provide a good choice for people with nickel allergies after sFDA registration, which is expected in one to two years. - Highlights: ► The nano lamella TiN coating did not change the shape-memory behavior and flexibility of the nitinol occluder. ► Nano lamella TiN coating modifications significantly reduced nickel release from nitinol ASD occluder. ► The new ASD occluder was found to be superior to nitinol ASD occluder with respect to both safety and efficacy

  18. Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhi xiong, E-mail: Top5460@163.com [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Fu, Bu fang, E-mail: fubnicpbp@163.com [National Institutes for Food and Drug Control, Beijing (China); Zhang, De yuan, E-mail: Deyuanzhangcn@yahoo.com.cn [Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen (China); Zhang, Zhi wei, E-mail: Zhzhx65@163.com [Guangdong Cardiovascular Institute, Guangzhou (China); Cheng, Yan, E-mail: chengyan@pku.edu.cn [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing (China); Sheng, Li yuan, E-mail: lysheng@yeah.net [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Lai, Chen, E-mail: laichen1110@163.com [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Xi, Ting fei, E-mail: Xitingfie@pku.edu.cn [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Academy for Advanced Interdisciplinary Studies, Peking University, Beijing (China)

    2013-04-01

    Atrial septal defect (ASD) occlusion devices made of nickel–titanium (NiTi) have a major shortcoming in that they release nickel into the body. We modified NiTi occluders using Arc Ion Plating technology. Nano lamellar titanium–nitrogen (TiN) coatings were formed on the surfaces of the occluders. The safety and efficacy of the modified NiTi occluders were evaluated in animal model. The results showed that 38 out of 39 rams (97%) survived at the end of the experiment. Fibrous capsules formed on the surfaces of the devices. Gradual endothelialization took place through the attachment of endothelial progenitor cells from the blood and the migration of endothelial cells from adjacent endocardium. The neo-endocardium formed more quickly in the coated group than in the uncoated group, as indicated by the evaluation of the six month study group. After TiN coating, there was no significant difference in endothelial cell cycle. TiN coating significantly reduced the release of nickel in both in vivo and in vitro indicating an improved biocompatibility of the nitinol ASD occluders. Superior and modified ASD occluders may provide a good choice for people with nickel allergies after sFDA registration, which is expected in one to two years. - Highlights: ► The nano lamella TiN coating did not change the shape-memory behavior and flexibility of the nitinol occluder. ► Nano lamella TiN coating modifications significantly reduced nickel release from nitinol ASD occluder. ► The new ASD occluder was found to be superior to nitinol ASD occluder with respect to both safety and efficacy.

  19. Phase II trial of 3D-conformal accelerated partial breast irradiation: Lessons learned from patients and physicians’ evaluation

    International Nuclear Information System (INIS)

    Azoury, Fares; Heymann, Steve; Acevedo, Catalina; Spielmann, Marc; Vielh, Philippe; Garbay, Jean-Rémi; Taghian, Alphonse G.; Marsiglia, Hugo; Bourgier, Céline

    2012-01-01

    Introduction: The present study prospectively reported both physicians’ and patients’ assessment for toxicities, cosmetic assessment and patients’ satisfaction after 3D-conformal accelerated partial breast irradiation (APBI). Materials and Methods: From October 2007 to September 2009, 30 early breast cancer patients were enrolled in a 3D-conformal APBI Phase II trial (40 Gy/10 fractions/5 days). Treatment related toxicities and cosmetic results were assessed by both patients and physicians at each visit (at 1, 2, 6 months, and then every 6 months). Patient satisfaction was also scored. Results: After a median follow-up of 27.7 months, all patients were satisfied with APBI treatment, regardless of cosmetic results or late adverse events. Good/excellent cosmetic results were noticed by 80% of patients versus 92% of cases by radiation oncologists. Breast pain was systematically underestimated by physicians (8–20% vs. 16.6–26.2%; Kappa coefficient KC = 0.16–0.44). Grade 1 and 2 fibrosis and/or breast retraction occurred in 7–12% of patients and were overestimated by patients (KC = 0.14–0.27). Conclusions: Present results have shown discrepancies between patient and physician assessments. In addition to the assessment of efficacy and toxicity after 3D-conformal APBI, patients’ cosmetic results consideration and satisfaction should be also evaluated.

  20. Study on the reactivity behavior partially loaded reactor cores using SIMULATE-3

    International Nuclear Information System (INIS)

    Holzer, Robert; Zeitz, Andreas; Grimminger, Werner; Lubczyk, Tobias

    2009-01-01

    The reactor core design for the NPP Gundremmingen unit B and C is performed since several years using the validated 3D reactor core calculation program SIMULATE-3. The authors describe a special application of the program to study the reactivity for different partial core loadings. Based on the comparison with results of the program CASMO-4 the program SIMULATE-3 was validated for the calculation of partially loaded reactor cores. For the planned reactor operation in NPP Gundremmingen using new MOX fuel elements the reactivity behavior was studied with respect to the KTA-Code requirements.

  1. A comparison of the fabrication times of all-ceramic partial crowns: Cerec 3D vs IPS Empress.

    Science.gov (United States)

    Gozdowski, S; Reich, S

    2009-01-01

    Apart from precision, the time factor plays a decisive role in the fabrication of all-ceramic dental restorations. Therefore, the aim of this study was to compare two all-ceramic systems with regard to the time required for the fabrication of partial crowns [MODB]. The null hypothesis tested was that the fabrication times of CAD/CAM generated partial crowns are shorter than the fabrication times of partial crowns manufactured in the laboratory. In sixteen model pairs mounted in the articulator, which corresponded to different clinical situations, tooth 36 was prepared for an all-ceramic partial crown [MODB]. With the Cerec3D method [CHAIR], the fabrication of the restoration was simulated directly on the "phantom patient". The IPS Empress system [LAB] was used forthe indirectfabrication method via an impression of the phantom patient. Both methods were used for each preparation. The adhesive luting procedure was not simulated and, therefore, not measured. The mean processing times [hh:mm:ss] were 00:35:05 (SD +/- 03:27 min) for the Cerec method and 04:17:54 (SD +/- 26:01 min) for the Empress method. The mean time on the phantom patient for process-induced activities was 11:47 minutes (SD +/- 02:08 min) for the Cerec method and 03:58 minutes (SD +/- 02:50 min) for the Empress method. Time expenditure for fabrication is only one aspect in order to assess the suitability of a restoration system. Both methods enable the dentist to provide high quality all ceramic restorations. Although the Empress method showed a time advantage of 65% during the fitting phase and occlusal grinding-in on the phantom patient in comparison to the Cerec method, the time spent during the laboratory phase has to be considered as well.

  2. Temporal Audiovisual Motion Prediction in 2D- vs. 3D-Environments.

    Science.gov (United States)

    Dittrich, Sandra; Noesselt, Tömme

    2018-01-01

    Predicting motion is essential for many everyday life activities, e.g., in road traffic. Previous studies on motion prediction failed to find consistent results, which might be due to the use of very different stimulus material and behavioural tasks. Here, we directly tested the influence of task (detection, extrapolation) and stimulus features (visual vs. audiovisual and three-dimensional vs. non-three-dimensional) on temporal motion prediction in two psychophysical experiments. In both experiments a ball followed a trajectory toward the observer and temporarily disappeared behind an occluder. In audiovisual conditions a moving white noise (congruent or non-congruent to visual motion direction) was presented concurrently. In experiment 1 the ball reappeared on a predictable or a non-predictable trajectory and participants detected when the ball reappeared. In experiment 2 the ball did not reappear after occlusion and participants judged when the ball would reach a specified position at two possible distances from the occluder (extrapolation task). Both experiments were conducted in three-dimensional space (using stereoscopic screen and polarised glasses) and also without stereoscopic presentation. Participants benefitted from visually predictable trajectories and concurrent sounds during detection. Additionally, visual facilitation was more pronounced for non-3D stimulation during detection task. In contrast, for a more complex extrapolation task group mean results indicated that auditory information impaired motion prediction. However, a post hoc cross-validation procedure (split-half) revealed that participants varied in their ability to use sounds during motion extrapolation. Most participants selectively profited from either near or far extrapolation distances but were impaired for the other one. We propose that interindividual differences in extrapolation efficiency might be the mechanism governing this effect. Together, our results indicate that both a

  3. Septic Complication After Balloon-Occluded Retrograde Transvenous Obliteration of Duodenal Variceal Bleeding

    International Nuclear Information System (INIS)

    Akasaka, Thai; Shibata, Toshiya; Isoda, Hiroyoshi; Taura, Kojiro; Arizono, Shigeki; Shimada, Kotaro; Togashi, Kaori

    2010-01-01

    We report a 64-year-old woman with duodenal varices who underwent balloon-occluded retrograde transvenous obliteration (B-RTO) complicated by intraprocedural variceal rupture. The patient developed shivering and a fever higher than 40 o C 3 days after the B-RTO procedure. A blood culture grew Entereobacter cloacoe. This case represents a rare septic complication of B-RTO for duodenal varices.

  4. DYNA3D2000*, Explicit 3-D Hydrodynamic FEM Program

    International Nuclear Information System (INIS)

    Lin, J.

    2002-01-01

    1 - Description of program or function: DYNA3D2000 is a nonlinear explicit finite element code for analyzing 3-D structures and solid continuum. The code is vectorized and available on several computer platforms. The element library includes continuum, shell, beam, truss and spring/damper elements to allow maximum flexibility in modeling physical problems. Many materials are available to represent a wide range of material behavior, including elasticity, plasticity, composites, thermal effects and rate dependence. In addition, DYNA3D has a sophisticated contact interface capability, including frictional sliding, single surface contact and automatic contact generation. 2 - Method of solution: Discretization of a continuous model transforms partial differential equations into algebraic equations. A numerical solution is then obtained by solving these algebraic equations through a direct time marching scheme. 3 - Restrictions on the complexity of the problem: Recent software improvements have eliminated most of the user identified limitations with dynamic memory allocation and a very large format description that has pushed potential problem sizes beyond the reach of most users. The dominant restrictions remain in code execution speed and robustness, which the developers constantly strive to improve

  5. Inward open characterization of EmrD transporter with molecular dynamics simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Xianwei [School of Life Sciences, Tsinghua University, Beijing 100084 (China); Wang, Boxiong, E-mail: boxiong_wang@yahoo.com [Department of Precision Instrument, Tsinghua University, Beijing 100084 (China)

    2016-06-10

    EmrD is a member of the multidrug resistance exporter family. Up to now, little is known about the structural dynamics that underline the function of the EmrD protein in inward-facing open state and how the EmrD transits from an occluded state to an inward open state. For the first time the article applied the AT simulation to investigate the membrane transporter protein EmrD, and described the dynamic features of the whole protein, the domain, the helices, and the amino acid residues during an inward-open process from its occluded state. The gradual inward-open process is different from the current model of rigid-body domain motion in alternating-access mechanism. Simulation results show that the EmrD inward-open conformational fluctuation propagates from a C-terminal domain to an N-terminal domain via the linker region during the transition from its occluded state. The conformational fluctuation of the C-terminal domain is larger than that of the N-terminal domain. In addition, it is observed that the helices exposed to the surrounding membrane show a higher level of flexibility than the other regions, and the protonated E227 plays a key role in the transition from the occluded to the open state. -- Highlights: •This study described the dynamic features of the whole EmrD protein, during an inward-open process from its occluded state. •The EmrD inward-open conformational fluctuation propagates from a C-terminal domain to an N-terminal domain via the linker region during the transition from its occluded state. •The conformational fluctuation of the C-terminal domain is larger than that of the N-terminal domain. •The protonated E227 plays a key role in the transition from the occluded to the open state.

  6. Inward open characterization of EmrD transporter with molecular dynamics simulation

    International Nuclear Information System (INIS)

    Tan, Xianwei; Wang, Boxiong

    2016-01-01

    EmrD is a member of the multidrug resistance exporter family. Up to now, little is known about the structural dynamics that underline the function of the EmrD protein in inward-facing open state and how the EmrD transits from an occluded state to an inward open state. For the first time the article applied the AT simulation to investigate the membrane transporter protein EmrD, and described the dynamic features of the whole protein, the domain, the helices, and the amino acid residues during an inward-open process from its occluded state. The gradual inward-open process is different from the current model of rigid-body domain motion in alternating-access mechanism. Simulation results show that the EmrD inward-open conformational fluctuation propagates from a C-terminal domain to an N-terminal domain via the linker region during the transition from its occluded state. The conformational fluctuation of the C-terminal domain is larger than that of the N-terminal domain. In addition, it is observed that the helices exposed to the surrounding membrane show a higher level of flexibility than the other regions, and the protonated E227 plays a key role in the transition from the occluded to the open state. -- Highlights: •This study described the dynamic features of the whole EmrD protein, during an inward-open process from its occluded state. •The EmrD inward-open conformational fluctuation propagates from a C-terminal domain to an N-terminal domain via the linker region during the transition from its occluded state. •The conformational fluctuation of the C-terminal domain is larger than that of the N-terminal domain. •The protonated E227 plays a key role in the transition from the occluded to the open state.

  7. Implications of natural occlusion of ventilated racks on ammonia and sanitation practices.

    Science.gov (United States)

    Creamer, Michelle A; Petty, Joann; Martin, Tara; Bergdall, Valerie; Hickman-Davis, Judy M

    2014-03-01

    Examination of ventilated rat racks prior to semiannual sanitation revealed silicone nozzles and ventilation ports that were partially or completely occluded with granular debris. We subsequently sought to document performance standards for rack sanitation and investigate the effect of ventilation port occlusion on rack function and animal husbandry practices. We hypothesized that individually ventilated cages with occluded airflow would require more frequent cage changes, comparable to those for static cages (that is, every 3 to 4 d). Sprague-Dawley rats were housed under one of 4 conditions: no airflow occlusion, occluded air-supply inlet, occluded air-exhaust outlet, and occlusion of both inlet and outlet. Cages were changed when daily ammonia concentration exceeded 20 ppm or after 14 d had elapsed. Most cages with unoccluded or partial airflow occlusion remained below the 20 ppm limit until day 12 or 13. Cages with occlusion of both inlet and outlet exceeded 20 ppm ammonia by as early as day 5. Airflow was significantly lower in cages with occlusion of both inlet and outlet airflow. Weekly inspection revealed that occlusion of ventilation ports was detectable by 3 mo after semiannual sanitation. This study demonstrates that silicone nozzles should be removed prior to rack sanitation to improve the effectiveness of cleaning ventilation ports and nozzles. While the rack is in use, silicone nozzles and ventilation ports should be inspected regularly to identify occlusion that is likely to diminish environmental quality in the cage. Intracage ammonia levels are significantly higher when both inlet and outlet airflow are occluded.

  8. Postoperative 3D spine reconstruction by navigating partitioning manifolds

    Energy Technology Data Exchange (ETDEWEB)

    Kadoury, Samuel, E-mail: samuel.kadoury@polymtl.ca [Department of Computer and Software Engineering, Ecole Polytechnique Montreal, Montréal, Québec H3C 3A7 (Canada); Labelle, Hubert, E-mail: hubert.labelle@recherche-ste-justine.qc.ca; Parent, Stefan, E-mail: stefan.parent@umontreal.ca [CHU Sainte-Justine Hospital Research Center, Montréal, Québec H3T 1C5 (Canada)

    2016-03-15

    Purpose: The postoperative evaluation of scoliosis patients undergoing corrective treatment is an important task to assess the strategy of the spinal surgery. Using accurate 3D geometric models of the patient’s spine is essential to measure longitudinal changes in the patient’s anatomy. On the other hand, reconstructing the spine in 3D from postoperative radiographs is a challenging problem due to the presence of instrumentation (metallic rods and screws) occluding vertebrae on the spine. Methods: This paper describes the reconstruction problem by searching for the optimal model within a manifold space of articulated spines learned from a training dataset of pathological cases who underwent surgery. The manifold structure is implemented based on a multilevel manifold ensemble to structure the data, incorporating connections between nodes within a single manifold, in addition to connections between different multilevel manifolds, representing subregions with similar characteristics. Results: The reconstruction pipeline was evaluated on x-ray datasets from both preoperative patients and patients with spinal surgery. By comparing the method to ground-truth models, a 3D reconstruction accuracy of 2.24 ± 0.90 mm was obtained from 30 postoperative scoliotic patients, while handling patients with highly deformed spines. Conclusions: This paper illustrates how this manifold model can accurately identify similar spine models by navigating in the low-dimensional space, as well as computing nonlinear charts within local neighborhoods of the embedded space during the testing phase. This technique allows postoperative follow-ups of spinal surgery using personalized 3D spine models and assess surgical strategies for spinal deformities.

  9. Postoperative 3D spine reconstruction by navigating partitioning manifolds

    International Nuclear Information System (INIS)

    Kadoury, Samuel; Labelle, Hubert; Parent, Stefan

    2016-01-01

    Purpose: The postoperative evaluation of scoliosis patients undergoing corrective treatment is an important task to assess the strategy of the spinal surgery. Using accurate 3D geometric models of the patient’s spine is essential to measure longitudinal changes in the patient’s anatomy. On the other hand, reconstructing the spine in 3D from postoperative radiographs is a challenging problem due to the presence of instrumentation (metallic rods and screws) occluding vertebrae on the spine. Methods: This paper describes the reconstruction problem by searching for the optimal model within a manifold space of articulated spines learned from a training dataset of pathological cases who underwent surgery. The manifold structure is implemented based on a multilevel manifold ensemble to structure the data, incorporating connections between nodes within a single manifold, in addition to connections between different multilevel manifolds, representing subregions with similar characteristics. Results: The reconstruction pipeline was evaluated on x-ray datasets from both preoperative patients and patients with spinal surgery. By comparing the method to ground-truth models, a 3D reconstruction accuracy of 2.24 ± 0.90 mm was obtained from 30 postoperative scoliotic patients, while handling patients with highly deformed spines. Conclusions: This paper illustrates how this manifold model can accurately identify similar spine models by navigating in the low-dimensional space, as well as computing nonlinear charts within local neighborhoods of the embedded space during the testing phase. This technique allows postoperative follow-ups of spinal surgery using personalized 3D spine models and assess surgical strategies for spinal deformities

  10. Study on transcatheter ASD occlusion using modified atrial septal defect occluder with no stainless steel screw in canine model

    International Nuclear Information System (INIS)

    Xuan Bin; Qin Yongwen; Hu Jianqiang; Wu Hong

    2006-01-01

    Objective: To evaluate the safety, biocompatibility and efficacy of transcatheter closure of atrial septal defect (ASD) with no stainless-steel-screw occluder in canine model. Methods: The device was constructed from superelastic Nitinol wires tightly woven into two flat disks and sewed with polyester fibers inside, with a pliable loop on the right-atrial-disk of the device, connecting to the delivery cable. ASD was created by transcatheter puncture and balloon dilatation and then closed by occluder under fluoroscopy in the catheterization laboratory. the location and the influence of the implanted device on function of tricuspid valve and mitral valve were evaluated by echocardiography. At 1, 2, 3 and 6 months after the operation, the animals were killed and autopsy was conducted. Results: Eight dogs with puncture-produced ASD underwent ASD closing procedure successfully. the occluder showed no influence on the function of MV and AV demonstrated by echocardiogram. The two disks of the implanted device were covered with a smooth intact neogenesis layer in all dogs. Endocardial cells fully covered the surface of the two disk without inflammating reaction 3 months later. There was no evidence of corrosion on the surface of the nitinol wire removed from the dog after 6 months. Light microscopic examination of the liver, kidney, lung and spleen showed no evidence of embolization and inflammation. Conclusion: Transcatheter ASD occlusion with new-type occluder is safe, feasible, effective and good biocompatibility with a good prospective clinical application. (authors)

  11. Novel 5-HT6 receptor antagonists/D2 receptor partial agonists targeting behavioral and psychological symptoms of dementia.

    Science.gov (United States)

    Kołaczkowski, Marcin; Marcinkowska, Monika; Bucki, Adam; Śniecikowska, Joanna; Pawłowski, Maciej; Kazek, Grzegorz; Siwek, Agata; Jastrzębska-Więsek, Magdalena; Partyka, Anna; Wasik, Anna; Wesołowska, Anna; Mierzejewski, Paweł; Bienkowski, Przemyslaw

    2015-03-06

    We describe a novel class of designed multiple ligands (DMLs) combining serotonin 5-HT6 receptor (5-HT6R) antagonism with dopamine D2 receptor (D2R) partial agonism. Prototype hybrid molecules were designed using docking to receptor homology models. Diverse pharmacophore moieties yielded 3 series of hybrids with varying in vitro properties at 5-HT6R and D2R, and at M1 receptor and hERG channel antitargets. 4-(piperazin-1-yl)-1H-indole derivatives showed highest antagonist potency at 5-HT6R, with 7-butoxy-3,4-dihydroquinolin-2(1H)-one and 2-propoxybenzamide derivatives having promising D2R partial agonism. 2-(3-(4-(1-(phenylsulfonyl)-1H-indol-4-yl)piperazin-1-yl)propoxy)benzamide (47) exhibited nanomolar affinity at both 5-HT6R and D2R and was evaluated in rat models. It displayed potent antidepressant-like and anxiolytic-like activity in the Porsolt and Vogel tests, respectively, more pronounced than that of a reference selective 5-HT6R antagonist or D2R partial agonist. In addition, 47 also showed antidepressant-like activity (Porsolt's test) and anxiolytic-like activity (open field test) in aged (>18-month old) rats. In operant conditioning tests, 47 enhanced responding for sweet reward in the saccharin self-administration test, consistent with anti-anhedonic properties. Further, 47 facilitated extinction of non-reinforced responding for sweet reward, suggesting potential procognitive activity. Taken together, these studies suggest that DMLs combining 5-HT6R antagonism and D2R partial agonism may successfully target affective disorders in patients from different age groups without a risk of cognitive deficits. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. Applications of 2D to 3D conversion for educational purposes

    Science.gov (United States)

    Koido, Yoshihisa; Morikawa, Hiroyuki; Shiraishi, Saki; Takeuchi, Soya; Maruyama, Wataru; Nakagori, Toshio; Hirakata, Masataka; Shinkai, Hirohisa; Kawai, Takashi

    2013-03-01

    There are three main approaches creating stereoscopic S3D content: stereo filming using two cameras, stereo rendering of 3D computer graphics, and 2D to S3D conversion by adding binocular information to 2D material images. Although manual "off-line" conversion can control the amount of parallax flexibly, 2D material images are converted according to monocular information in most cases, and the flexibility of 2D to S3D conversion has not been exploited. If the depth is expressed flexibly, comprehensions and interests from converted S3D contents are anticipated to be differed from those from 2D. Therefore, in this study we created new S3D content for education by applying 2D to S3D conversion. For surgical education, we created S3D surgical operation content under a surgeon using a partial 2D to S3D conversion technique which was expected to concentrate viewers' attention on significant areas. And for art education, we converted Ukiyoe prints; traditional Japanese artworks made from a woodcut. The conversion of this content, which has little depth information, into S3D, is expected to produce different cognitive processes from those evoked by 2D content, e.g., the excitation of interest, and the understanding of spatial information. In addition, the effects of the representation of these contents were investigated.

  13. Safety, dose, and timing of reteplase in treating occluded central venous catheters in children with cancer.

    Science.gov (United States)

    Terrill, Kelly R; Lemons, Richard S; Goldsby, Robert E

    2003-11-01

    Recombinant tissue plasminogen activator, alteplase, began to be commonly used to restore the patency of occluded central venous catheters (CVCs) as urokinase production was halted in the late 1990s. However, alteplase often requires an extended dwell time to restore patency to occluded CVCs. In adults, reteplase, a newer thrombolytic agent, has been reported to restore patency to CVCs in 30 minutes. The authors prospectively evaluated the safety and efficacy of reteplase in restoring patency to occluded CVCs in children with cancer. This was a dose escalation trial. The dose of reteplase was initiated at 0.1 units and increased by increments of 0.1 units to a maximum dose of 0.4 units. Each dose was tested on at least three participants. Time to patency after reteplase administration was recorded by nurses caring for the patients. Attempts to access the line occurred every 15 minutes for 1 hour. CVCs that remained occluded after 1 hour were treated with alteplase. Reteplase was administered to 15 clotted CVCs. Twelve of the 15 were cleared with an average dwell time of 38 minutes. The time to patency did not appear to correlate with the dose. No adverse events were reported. Reteplase can restore patency to occluded CVCs in a pediatric population. Reteplase appears to have comparable efficacy with alteplase, but reteplase may require shorter dwell times. A prospective, randomized, clinical trial is warranted to determine whether reteplase is as effective as alteplase in restoring patency to occluded CVCs.

  14. Partial breaking of N = 1, D = 10 supersymmetry

    International Nuclear Information System (INIS)

    Bellucci, S.

    1999-01-01

    In this paper is described the spontaneous partial breaking of N =1, D =10 supersymmetry to N = (1, 0), d = 6 and its dimensionally-reduced versions in the framework of nonlinear realizations. The basic Goldstone superfield is N = (1, 0), d = 6 hyper multiplet superfield satisfying a nonlinear generalization of the standard hyper multiplet constraint. It is here interpreted the generalized constraint as the manifestly world volume supersymmetric form of equations of motion of the type 1 super 5-brane in D 10. The related issues here addressed are a possible existence of brane extension of off-shell hyper multiplet actions, the possibility to utilize vector N = (1, 0), d =6 supermultiplet as the Goldstone one, and the description of 1/4 breaking of N =1, D = 11 supersymmetry

  15. In vitro evaluation of the sinus sagittalis superior thrombosis model in the rat using 3D micro- and nanocomputed tomography

    International Nuclear Information System (INIS)

    Langheinrich, Alexander Claus; Ostendorf, Anne; Kampschulte, Marian; Yeniguen, Mesut; Marhoffer, Simone; Nedelmann, Max; Stolz, Erwin; Gerriets, Tibo; Dierkes, Christian; Gerlach, Susanne von; Bachmann, Georg

    2010-01-01

    Thrombosis of the cerebral veins and sinus are common causes of stroke. Animal models help us to understand the underlying pathophysiology of this condition. Therefore, the purpose of our study was to evaluate a well-established model for sinus sagittalis (SSS) thrombosis using micro- and nanocomputed tomography (CT) imaging. SSS thrombosis was performed in four rats. After contrast perfusion, brains were isolated and scanned using micro-CT at (8 μm) 3 voxel size to generate 3D images of the cerebral vasculature. For more detailed information on vascular perfusion territories, nano-CT imaging was performed to investigate the boundary layer of contrast-enhanced vessels and the occluded veins. The venous and arterial vascular volume fraction and gray scale measurements were obtained in the SSS thrombosis group and compared to controls. The significance of differences in vascular volume fraction and gray scale measurements was tested with analysis of variance. Results were complemented with histology. Micro-CT proved to accurately visualize and differentiate vascular occlusion territories performed in the SSS thrombosis model. Moreover, 3D micro-CT provided quantitative information on arterial and venous vascular volume fraction. Micro-CT imaging enables a total 3D visualization of complications (ventricle rupture) in the SSS thrombosis model. We established gray scale measurements by which focal cerebral ischemia could be radiographically categorized (p < 0.001). Using nano-CT, the interface of contrast-perfused and occluded veins can be visualized. Micro-CT is feasible for analysis and differentiation of perfusion territories in an animal model of focal cerebral ischemia. (orig.)

  16. Leach resistance properties and release processes for salt-occluded zeolite A

    International Nuclear Information System (INIS)

    Lewis, M.A.; Fischer, D.F.; Laidler, J.J.

    1992-01-01

    The pyrometallurgical processing of spent fuel from the Integral Fast Reactor (IFR) results in a waste of LiCl-KCl-NaCl salt containing approximately 10 wt% fission products, primarily CsCl and SrCl 2 . For disposal, this waste must be immobilized in a form that it is leach resistant. A salt-occluded zeolite has been identified as a potential waste form for the salt. Its leach resistance properties were investigated using powdered samples. The results were that strontium was not released and cesium had a low release, 0.056 g/m 2 for the 56 day leach test. The initial release (within 7 days) of alkali metal cations was rapid and subsequent releases were much smaller. The releases of aluminum and silicon were 0.036 and 0.028 g/m 2 , respectively, and were constant. Neither alkali metal cation hydrolysis nor exchange between cations in the leachate and those in the zeolite was significant. Only sodium release followed t 0.5 kinetics. Selected dissolution of the occluded salt was the primary release process. These results confirm that salt-occluded zeolite has promise as the waste form for IFR pyroprocess salt

  17. [Effects of removable partial dentures on the quality of life in people with shortened dental arches].

    Science.gov (United States)

    Armellini, D B; Heydecke, G; Witter, D J; Creugers, N H J

    2009-12-01

    In order to assess the enhanced value of removable partial dentures on the quality of life, patients at 2 university clinics were screened for the presence of complete or shortened dental arches. Those selected were assigned to 1 of 5 subgroups: 1) a shortened dental arch with all frontal teeth, 2) a shortened dental arch with one or more frontal diastemas, 3) a shortened dental arch with all frontal teeth, restored by a removable partial denture, 4) a shortened dental arch and several diastemas, restored by a removable partial denture, 5) a complete dental arch. The participants completed the Oral Health Impact Profile (OHIP-49) and the Short Form Health Survey (SF-36). Clinical data recorded were: whether any teeth were missing and if so which, whether or not these had been replaced by a removable partial denture, and the number of occluding pairs of (pre)molars. The results revealed that a shortenend dental arch has a certain impact on the quality of life. However, the participants only experienced benefits from a removable partial denture if the denture also replaced frontal teeth.

  18. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder

    Directory of Open Access Journals (Sweden)

    Er-Ping Xi

    2012-11-01

    Full Text Available OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen Co., LTD, Guangdong, China utilizing standard techniques. RESULTS: Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. CONCLUSION: Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.

  19. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder.

    Science.gov (United States)

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-11-01

    Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired, patient examinations revealed ventricular septal defects with pulmonary/systemic flow ratios (Qp/Qs) of over 1.7. The post-traumatic ventricular septal defects were closed percutaneously with a patent ductus arteriosus occluder (Lifetech Scientific (Shenzhen) Co., LTD, Guangdong, China) utilizing standard techniques. Post-operative transthoracic echocardiography revealed no residual left-to-right shunt and indicated normal ventricular function. In addition, 320-slice computerized tomography showed that the occluder was well placed and exhibited normal morphology. Our experiences indicate that closure of a post-traumatic ventricular septal defect using a patent ductus arteriosus occluder is feasible, safe, and effective.

  20. Occlusion of blood flow attenuates exercise-induced hypoalgesia in the occluded limb of healthy adults.

    Science.gov (United States)

    Jones, Matthew D; Taylor, Janet L; Barry, Benjamin K

    2017-05-01

    Animal studies have demonstrated an important role of peripheral mechanisms as contributors to exercise-induced hypoalgesia (EIH). Whether these same mechanisms contribute to EIH in humans is not known. In the current study, pain thresholds were assessed in healthy volunteers ( n = 36) before and after 5 min of high-intensity leg cycling exercise and an equivalent period of quiet rest. Pressure pain thresholds (PPTs) were assessed over the rectus femoris muscle of one leg and first dorsal interosseous muscles (FDIs) of both arms. Blood flow to one arm was occluded by a cuff throughout the 5-min period of exercise (or rest) and postexercise (or rest) assessments. Ratings of pain intensity and pain unpleasantness during occlusion were also measured. Pain ratings during occlusion increased over time (range, 1.5 to 3.5/10, all d > 0.63, P exercise conditions ( d 0.4). PPTs at all sites were unchanged following rest (range, -1.3% to +0.9%, all d 0.51). Consistent with EIH, exercise significantly increased PPT at the leg (+29%, d = 0.69, P exercise attenuates EIH, suggesting that peripheral factors contribute to EIH in healthy adults. NEW & NOTEWORTHY This is the first demonstration in humans that a factor carried by the circulation and acting at the periphery is important for exercise-induced hypoalgesia. Further understanding of this mechanism may provide new insight to pain relief with exercise as well as potential interactions between analgesic medications and exercise. Copyright © 2017 the American Physiological Society.

  1. Bone mineral content (BMC) and serum vitamin D concentrations of infants fed partially hydrolyzed infant formulas

    Science.gov (United States)

    The purpose of the study was to compare the bone status of healthy, term infants fed partially hydrolyzed whey formulas during the first 3 mo of life. Between 0 and 8 d of age, 89 infants were randomized to Good Start Supreme (GSS) or an experimental whey-based formula (EF) to 84 d of age. BMC was a...

  2. Computation of 3D thermohydraulics in partially blocked bundles during the reflood phase of a LOCA

    International Nuclear Information System (INIS)

    Cicero, G.M.; Briere, E.; Fornaciari, G.

    1994-06-01

    In Pressurized Water Reactors (PWR), ballooning of the fuel rod claddings may occur during a LOCA, since the fuel rod claddings are heated up, and the system pressure is low. The severe blockages that may result induce cross-flow diversion and three-dimensional effects on thermohydraulics in the core bundle, during the reflood phase. To improve the knowledge of these phenomena and their physical modelling in the code CATHARE, 3D computer codes are needed. In 1990, EDF has started up a development and validation program of the 3D THYC computer code to analyze the thermohydraulics of the flow during the reflood phase, in partially blocked bundles. The main objective is to calculate the temperatures of the rods above the quench front, when they are cooled by superheated steam with saturated droplets. First, this paper introduces the THYC model developed for reflood studies. Secondly, we report the first qualification results on a Flooding Experiments with Blocked Array (FEBA) test. Thirdly, we analyze the model predictions on a large break LOCA transient, in a 900 MW PWR 11x11 core area with a 3x3 central blockage. THYC simulates the transient in the bundle around and above the blockage, until the quench front enters the computational domain. Previously, a 1D CATHARE simulation gives the boundary conditions and, in the reactor core case, the deformation of the blocked fuel rods. The results analysis focused on the time evolution of the clad temperatures in the blocked and in the bypass region. In the FEBA test simulation, the main observations are properly predicted within the blockage. Temperatures are lower in blocked rod sleeves than in unblocked rod claddings since the steam gap reduces the power transmitted by the heater rod to the sleeve. In the core case, the model predicts the opposite result. Within the blockage, ballooned rod temperatures are higher than non-ballooned rod ones. We show by sensitivity studies that these behaviour difference between FEBA rods

  3. Aorto-right atrial fistula secondary to rupture of an occluded old saphenous venous graft to right coronary artery.

    Science.gov (United States)

    Balestrini, Carlos Sebastian; Saaibi, José Federico; Ortiz, Santiago Navas

    2014-09-01

    We report a case of an acquired aorta-right atrial fistula, secondary to a ruptured proximal anastomosis of an old saphenous vein graft 12 years after a coronary artery bypass surgery, in a 57 year old patient with multiple cardiovascular risk factors. On admission, he presented with congestive heart failure and on examination a continuous murmur was detected on the right parasternal border. Catheterization showed a fistula from the proximal anastomosis of an occluded right coronary artery saphenous vein graft draining to the right atrium with a large left to right shunt. The fistula was successfully occluded by a percutaneous approach with a Life Tech duct occluder with complete resolution of heart failure. The patient was discharged one week afterwards. After a two-year follow-up, the fistula remained occluded. © 2013 Wiley Periodicals, Inc.

  4. Supraspinatus tendon tears: comparison of 3D US and MR arthrography with surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chang Ho [Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea); Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea); Kim, Sam Soo [Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea); Kim, Jung Hyuk; Chung, Kyoo Byung; Kim, Yun Hwan; Oh, Yu-Whan [Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea); Jeong, Woong-Kyo [Korea University Anam Hospital, Korea University College of Medicine, Orthopaedic Surgery, Seoul (Korea); Kim, Baek Hyun [Korea University Ansan Hospital, Korea University College of Medicine, Department of Radiology, Ansan City (Korea)

    2009-11-15

    The objective of the study was to compare the diagnostic reliability of 3D US with MR arthrography in diagnosing supraspinatus tendon tears, with arthroscopic findings used as the standard. In a prospective study 50 patients who later underwent arthroscopic surgery of the rotator cuff were examined pre-operatively by 3D US with MR arthrography. The presence or absence of a full- or partial-thickness supraspinatus tendon tear and the tear size as demonstrated by each imaging and arthroscopy was recorded. The tear size was divided into three grades: small (<1 cm), medium (1-3 cm), and large (>3 cm). The arthroscopic diagnosis was a full-thickness tear in 40 patients, partial-thickness tears in 5, and intact supraspinatus tendon in 5. 3D US correctly diagnosed 35 out of 40 full-thickness tears and MR arthrography 39 out of 40 full-thickness tears. Regarding partial-thickness tears, 3D US underestimated 2 cases as no tear and overestimated 1 case as a full-thickness tear. MR arthrography underestimated 1 case as a partial-thickness tear and overestimated 2 cases as full-thickness and partial-thickness tears respectively. 3D US and MR arthrography yield a sensitivity for full-thickness tears of 87.5% and 97.5% with specificity of 90.0% and 90.0%. Based on the grading system, 3D US measurements correctly predicted the tear size of 23 (65.7%) of the 35 full-thickness tears and MR arthrography 30 (75.0%) of the 39 full-thickness tears. Three-dimensional ultrasound seems to be a promising imaging modality comparable to MR arthrography for the assessment of the supraspinatus tendon tears. (orig.)

  5. Successful Balloon-Occluded Retrograde Transvenous Obliteration for Gastric Varix Mainly Draining into the Pericardiophrenic Vein

    International Nuclear Information System (INIS)

    Kageyama, Ken; Nishida, N.; Matsui, H.; Yamamoto, A.; Nakamura, K.; Miki, Y.

    2012-01-01

    Two cases of gastric varices were treated by balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein at our hospital, and both were successful. One case developed left hydrothorax. Gastric varices did not bled and esophageal varices were not aggravated in both cases for 24–30 months thereafter. These outcomes indicate the feasibility of balloon-occluded retrograde transvenous obliteration via the pericardiophrenic vein.

  6. Transcatheter Closure of Bilateral Multiple Huge Pulmonary Arteriovenous Malformations with Homemade Double-Umbrella Occluders

    International Nuclear Information System (INIS)

    Zhong Hongshan; Xu Ke; Shao Haibo

    2008-01-01

    A 28-year-old man underwent successful transcatheter occlusion of three huge pulmonary arteriovenous malformations (PAVMs) using homemade double-umbrella occluders and stainless steel coils. Thoracic CT with three-dimensional reconstruction and pulmonary angiography were used for treatment planning and follow-up. The diameters of the feeding vessels were 11 mm, 13 mm, and 14 mm, respectively. This report demonstrates the novel design and utility of the double-umbrella occluder, an alternative tool for treatment of large PAVMs.

  7. Recanalisation of Chronically Occluded Remote Superficial Femoral Artery Endarterectomy Through Angioplasty for Limb Salvage

    Energy Technology Data Exchange (ETDEWEB)

    Husainy, Mohammad Ali, E-mail: m.husainy@nhs.net [King’s College Hospital, Department of Radiology (United Kingdom); Slim, Hani; Rashid, Hisham [King’s College Hospital, Department of Vascular Surgery (United Kingdom); Huang, Dean Y. [King’s College Hospital, Department of Radiology (United Kingdom)

    2017-02-15

    We report a novel application of balloon angioplasty to recanalise a chronically occluded remote endarterectomy superficial femoral artery. This patient previously had two occluded surgical bypass grafts in an attempt to revascularise the limb and presented with critical limb ischaemia and necrotic foot ulcerations. Following the angioplasty, the patient showed significant improvement in rest pain and healing of the ulcerations. This technique may be useful for limb salvage in patients where surgical options have been exhausted.

  8. Early experience with the Occlutech PLD occluder for mitral paravalvar leak closure through a hybrid transapical approach.

    Science.gov (United States)

    Bedair, Radwa; Morgan, Gareth J; Bapat, Vinayak; Kapetanakis, Stamatis; Goreczny, Sebastian; Simpson, John; Qureshi, Shakeel A

    2016-12-10

    We sought to evaluate the feasibility and efficacy of hybrid transapical closure of paravalvar mitral leaks using a new Occlutech PLD occluder in patients with heart failure and/or haemolytic anaemia. Retrospective analysis of clinical and procedural data was undertaken for patients who had attempted closure of paravalvar mitral leaks via a hybrid transapical approach with the Occlutech PLD occluder. Eight patients (four males, median age 69 years) underwent closure of 10 mitral paravalvar leaks using eight Occlutech PLD occluders and two AMPLATZER Vascular Plugs (AVP II). Successful deployment, with significant reduction of the paravalvar leak was achieved in seven patients with short procedure (median 131 min) and fluoroscopy times (median 22 min). One patient had mechanical interference with prosthetic valve function, requiring surgery. Another patient with a high EuroSCORE (48.8%) died of multi-organ failure two days after the procedure. Clinical improvement in either heart failure or haemolysis was seen in all discharged patients. In our series of patients with challenging anatomy, the Occlutech PLD occluders performed well when implanted via a hybrid transapical approach. Further work is needed to assess this methodology fully for a wider population and to assess other deployment approaches for this promising new occluder.

  9. In Situ 3D Segmentation of Individual Plant Leaves Using a RGB-D Camera for Agricultural Automation

    Directory of Open Access Journals (Sweden)

    Chunlei Xia

    2015-08-01

    Full Text Available In this paper, we present a challenging task of 3D segmentation of individual plant leaves from occlusions in the complicated natural scene. Depth data of plant leaves is introduced to improve the robustness of plant leaf segmentation. The low cost RGB-D camera is utilized to capture depth and color image in fields. Mean shift clustering is applied to segment plant leaves in depth image. Plant leaves are extracted from the natural background by examining vegetation of the candidate segments produced by mean shift. Subsequently, individual leaves are segmented from occlusions by active contour models. Automatic initialization of the active contour models is implemented by calculating the center of divergence from the gradient vector field of depth image. The proposed segmentation scheme is tested through experiments under greenhouse conditions. The overall segmentation rate is 87.97% while segmentation rates for single and occluded leaves are 92.10% and 86.67%, respectively. Approximately half of the experimental results show segmentation rates of individual leaves higher than 90%. Nevertheless, the proposed method is able to segment individual leaves from heavy occlusions.

  10. Partial thyroid arterial embolization for the treatment of hyperthyroidism

    International Nuclear Information System (INIS)

    Brzozowski, Krzysztof; Piasecki, Piotr; Zięcina, Piotr; Frankowska, Emilia; Jaroszuk, Andrzej; Kamiński, Grzegorz; Bogusławska-Walecka, Romana

    2012-01-01

    Background: Hyperactive thyroid gland in patients that are unable to tolerate or accept standard therapy is a common clinical problem. Aim of the study was to evaluate effectiveness of partial thyroid arterial embolization in patients with hyperthyroidism. Material/methods: From May 2004 to November 2005 partial thyroid gland embolization was performed in 15 patients. Mean thyroid gland volume was 162 ml. Embolization of one to three thyriod arteries was performed with the mixture of Histoacryl and Lipiodol. Selective angiography was performed after embolization to ensure that the targeted arteries were completely occluded. Follow-up study covered 12 patients. Results: The embolization procedure was well tolerated by all patients. Three days after embolization fT3 and fT4 levels were higher than before the procedure. Further laboratory tests showed quick reversal to near-normal or normal levels of thyroid hormones. 12 weeks follow-up showed: normal serum levels of fT3, fT4 and TSH in 9 of 12 patients (75%), hyperthyroidism in 3 of 12 patients (25%), goiter volume reduction of approximately 32% of its original volume (from 13 to 76.3%), mean thyroid gland volume of 94 ml. One year after embolization 7 of 12 patients required thyreostatic drugs. At two and four years follow-up thyreostatics doses were significantly lower and thyroid tissue was fibrotic. Conclusions: Based on our results the treatment of the thyroid gland goiters using arterial thyroid gland partial embolization may be offered as an effective alternative for patients who will not or cannot accept standard therapy.

  11. Measurement of BETA(B sup 0 -> D* sub s sup + D* sup -) and Determination of the D sub s sup + -> phi pi sup + Branching Fraction with a Partial-Reconstruction Method

    CERN Document Server

    Covarelli, R

    2003-01-01

    The present model-independent measurements of the branching fractions BETA(B sup 0 -> D* sub s sup + D* sup -) and BETA(D sub s sup + -> phi pi sup +) based on 19.3 fb sup - sup 1 of data collected by the BABAR detector at the PEP-II e sup + e sup - B Factory. Neutral B-meson decays to the D* sub s sup + D* sup - final state are selected with a partial reconstruction of the D* sub s sup +; that is, only the D* sup - and the soft photon from the decay D* sub s sup + -> D sub s sup +gamma are reconstructed. The branching fraction BETA(B sup 0 -> D* sub s sup + D* sup -) is extracted from these event yields, while BETA(D sub s sup + -> phi pi sup +) is determined by combining this result with a previous measurement of the product BETA(B sup 0 -> D* sub s sup + D* sup -) x BETA(D sub s sup + -> phi pi sup +) with partial reconstruction of the D* sup -. They obtain the following preliminary results: BETA(B sup 0 -> D* sub s sup + D* sup -) = (1.50 +- 0.16 +- 0.12)%, BETA(D sub s sup + -> phi pi sup +) = (4.7 +- 0....

  12. Supraspinatus tendon tears: comparison of 3D US and MR arthrography with surgical correlation

    International Nuclear Information System (INIS)

    Kang, Chang Ho; Kim, Sam Soo; Kim, Jung Hyuk; Chung, Kyoo Byung; Kim, Yun Hwan; Oh, Yu-Whan; Jeong, Woong-Kyo; Kim, Baek Hyun

    2009-01-01

    The objective of the study was to compare the diagnostic reliability of 3D US with MR arthrography in diagnosing supraspinatus tendon tears, with arthroscopic findings used as the standard. In a prospective study 50 patients who later underwent arthroscopic surgery of the rotator cuff were examined pre-operatively by 3D US with MR arthrography. The presence or absence of a full- or partial-thickness supraspinatus tendon tear and the tear size as demonstrated by each imaging and arthroscopy was recorded. The tear size was divided into three grades: small ( 3 cm). The arthroscopic diagnosis was a full-thickness tear in 40 patients, partial-thickness tears in 5, and intact supraspinatus tendon in 5. 3D US correctly diagnosed 35 out of 40 full-thickness tears and MR arthrography 39 out of 40 full-thickness tears. Regarding partial-thickness tears, 3D US underestimated 2 cases as no tear and overestimated 1 case as a full-thickness tear. MR arthrography underestimated 1 case as a partial-thickness tear and overestimated 2 cases as full-thickness and partial-thickness tears respectively. 3D US and MR arthrography yield a sensitivity for full-thickness tears of 87.5% and 97.5% with specificity of 90.0% and 90.0%. Based on the grading system, 3D US measurements correctly predicted the tear size of 23 (65.7%) of the 35 full-thickness tears and MR arthrography 30 (75.0%) of the 39 full-thickness tears. Three-dimensional ultrasound seems to be a promising imaging modality comparable to MR arthrography for the assessment of the supraspinatus tendon tears. (orig.)

  13. Morphological image processing operators. Reduction of partial volume effects to improve 3D visualization based on CT data

    International Nuclear Information System (INIS)

    Beier, J.; Bittner, R.C.; Hosten, N.; Troeger, J.; Felix, R.

    1998-01-01

    Aim: The quality of segmentation and three-dimensional reconstruction of anatomical structures in tomographic slices is often impaired by disturbances due to partial volume effects (PVE). The potential for artefact reduction by use of the morphological image processing operators (MO) erosion and dilation is investigated. Results: For all patients under review, the artefacts caused by PVE were significantly reduced by erosion (lung: Mean SBR pre =1.67, SBR post =4.83; brain: SBR pre =1.06, SBR post =1.29) even with only a small number of iterations. Region dilation was applied to integrate further structures (e.g. at tumor borders) into a configurable neighbourhood for segmentation and quantitative analysis. Conclusions: The MO represent an efficient approach for the reduction of PVE artefacts in 3D-CT reconstructions and allow optimised visualization of individual objects. (orig./AJ) [de

  14. Clinical assessment of transcatheter closure of patent ductus arteriosus with severe pulmonary hypertention using Amplatzer occluder

    Energy Technology Data Exchange (ETDEWEB)

    Xiumin, Han; Xianyang, Zhu; Yuwei, Zhang; Yan, Jin; Dong' an, Deng; Chanju, Hou; Wei, Quan [Shenyang General Hospital, PLA, Shenyang (China)

    2004-04-01

    Objective: To evaluate the application of transcatheter closure of patent ductus arteriosus (PDA) with severe pulmonary hypertention using the Amplatzer occluder device. Methods: Fifty-one cases of PDA with severe pulmonary hypertention were treated by transcatheter closure with Amplatzer occluder. Patients mean age was 9.4 years (ranging 3 months to 60 years) and the mean weight was (18.7 {+-} 13.8) kg (ranging 5.0 to 65.0 kg). The mean PDA diameter at its narrowest segment was (7.0 {+-} 2.4) (ranging 3.0 to 15.0) mm. The achievement of permanent transcatheter closure was decided according to the change of the pulmonary arterial pressure, aortic pressure and oxygen saturation. Results: The devices were successfully placed in all patients except one failure owing to the resistance of pulmonary hypertention. The systolic pulmonary pressure decreased from (84.7 {+-} 13.5) (range 70 to 137) to mmHg to (46.1 {+-} 14.9) (24 to 109) mmHg, and the mean pulmonary pressure decreased from (65.0 {+-} 11.5) (42 to 97) mmHg to (31.3 {+-} 11.6) (14 to 69) mmHg. Complete angiographic closure was seen 10 minutes after the device deployment in 30 out of 50 patients (60%), while trivial to small leak was present in 20 (40%). Complete echocardiographic closure was demonstrated in 49 out of 50 patients (98%) at 10 min, and 100% at 6-month follow-up in all patients. There were no PDA recanalization and migration of devices after the complete occlusion during following up. Conclusion: Transcatheter closure of patent ductus arteriosus with severe pulmonary hypertention by using the Amplatzer occluder is a safe and effective interventional method with excellent short-term and middle-term results. (authors)

  15. Clinical assessment of transcatheter closure of patent ductus arteriosus with severe pulmonary hypertention using Amplatzer occluder

    International Nuclear Information System (INIS)

    Han Xiumin; Zhu Xianyang; Zhang Yuwei; Jin Yan; Deng Dong'an; Hou Chanju; Quan Wei

    2004-01-01

    Objective: To evaluate the application of transcatheter closure of patent ductus arteriosus (PDA) with severe pulmonary hypertention using the Amplatzer occluder device. Methods: Fifty-one cases of PDA with severe pulmonary hypertention were treated by transcatheter closure with Amplatzer occluder. Patients mean age was 9.4 years (ranging 3 months to 60 years) and the mean weight was (18.7 ± 13.8) kg (ranging 5.0 to 65.0 kg). The mean PDA diameter at its narrowest segment was (7.0 ± 2.4) (ranging 3.0 to 15.0) mm. The achievement of permanent transcatheter closure was decided according to the change of the pulmonary arterial pressure, aortic pressure and oxygen saturation. Results: The devices were successfully placed in all patients except one failure owing to the resistance of pulmonary hypertention. The systolic pulmonary pressure decreased from (84.7 ± 13.5) (range 70 to 137) to mmHg to (46.1 ± 14.9) (24 to 109) mmHg, and the mean pulmonary pressure decreased from (65.0 ± 11.5) (42 to 97) mmHg to (31.3 ± 11.6) (14 to 69) mmHg. Complete angiographic closure was seen 10 minutes after the device deployment in 30 out of 50 patients (60%), while trivial to small leak was present in 20 (40%). Complete echocardiographic closure was demonstrated in 49 out of 50 patients (98%) at 10 min, and 100% at 6-month follow-up in all patients. There were no PDA recanalization and migration of devices after the complete occlusion during following up. Conclusion: Transcatheter closure of patent ductus arteriosus with severe pulmonary hypertention by using the Amplatzer occluder is a safe and effective interventional method with excellent short-term and middle-term results. (authors)

  16. Budget impact analysis of the percutaneous septal occluder for treatment of ostium secundum atrial septal defects in the Brazilian Unified National Health System.

    Science.gov (United States)

    Senna, Kátia Marie Simões e; Sarti, Flavia Mori; Costa, Márcia Gisele Santos da; Nita, Marcelo Eidi; Santos, Marisa da Silva; Tura, Bernardo Rangel; Correia, Marcelo Goulart

    2015-08-01

    The aim of this study was to perform a budget impact analysis on the adoption of percutaneous occlusion of ostium secundum atrial septal defects in the Brazilian Unified National Health System. Costs were collected using micro-costing technique from medical records for each treatment technique (conventional surgery versus percutaneous septal occluder) at a public federal hospital specialized in high-complexity cardiology. The analysis showed that expenditures associated with percutaneous occlusion were lower than with conventional surgery, and sensitivity analysis confirmed the cost reduction in several scenarios, showing a significant budget impact with a 30% adoption rate for the percutaneous occluder (savings of approximately 1.5 million dollars per year). The study indicates that the adoption of the percutaneous septal occluder would mean cost savings of approximately 3.5 million dollars for the Brazilian public health system.

  17. Quantitative analysis of occluded gases in uranium dioxide pellets by the mass spectrometry technique

    International Nuclear Information System (INIS)

    Vega Bustillos, J.O.W.; Rodrigues, C.; Iyer, S.S.

    1981-05-01

    A quantitative analysis of different components of occluded gases except water in uranium dioxide pellets is attempted here. A high temperature vacuum extration system is employed for the liberation and the determination of total volume of the occluded gases. A mass spectrometric technique is employed for the qualitative and quantitative analysis of these gases. The UO 2 pellets are placed in a graphite crucible and are subjected to varing temperatures (1000 0 C - 1700 0 C). The liberated gases are dehydrated and transferred to a measuring unit consisting essentially of a Toepler pump and a McLeod gauge. In this system the total volume of the gases liberated at N. T. P. is determined with a sensitivity of 0.002 cm 3 /g of UO 2 . An aliquot of the liberated gas is introduced into a quadrupole mass spectrometer (VGA-100 Varian Corp.) for the determination of the different components of the gas. On the basis of the analysis suggestions are made for the possible sources of these gas components. (Author) [pt

  18. A novel method of creation of a fenestration in nitinol occluder devices used in closure of hypertensive patent arterial ducts

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2016-01-01

    Full Text Available Test occlusion with a balloon is done to predict operability of large hypertensive patent ductus arteriosus (PDA. If the fall in the pulmonary artery pressures is inadequate, a complete closure is not desired. To create a predictable premeasured fenestration in a nitinol occluder device used for closing hypertensive PDA. A large nitinol occluder device was punctured with an 18G needle to advance a 0.035½ stiff guide wire through the occluder before loading it into the delivery system. The occluder with the guidewire was then deployed across the PDA. A coronary guide catheter was later threaded through the guidewire into the fabric of the device, which was still held by the delivery cable. A coronary stent was deployed across the fenestration in the occluder to keep it patent. An 8-year-old boy with Down syndrome and hypertensive PDA was hemodynamically assessed. Even though there was a fall in the pulmonary vascular resistance index and pressures on test occlusion, the pulmonary artery pressures were labile with fluctuations. A customized fenestration was made in a 16 mm muscular ventricular septal defect occluder (MVSO with a 4.5 mm bare-metal coronary stent. The pulmonary artery pressures remained at half of the aortic pressures after the procedure. This fenestration model precisely and predictably fenestrated a large occluder device used to close a hypertensive large PDA. Long-term patency of these fenestrations has to be assessed on the follow-up, and may be improved through larger fenestrations, systemic anticoagulation and use of covered stents.

  19. Transcatheter coil occluder for closure of ventricular septal defect (a report of 4 cases)

    International Nuclear Information System (INIS)

    Gao Wei; Zhou Aiqing; Yu Zhiqing; Li Fen; Zhong Yumin; Zhang Yuqi; Huang Meirong; Sun Kun

    2005-01-01

    Objective: To explore the indication, methodology and complication of transcatheter coil closure of ventricular septal defect (VSD) in children. Methods: Transcatheter closure of perimembranous VSD with coils was performed in 4 cases from 2003 to 2005. The Duct-Occlude (pfm) and detachable coil (Cook) were chosen for embolization depending on the results of the left ventricular angiogram. The coil size was generally about 1-4 mm larger than the diameter of VSD. Follow up was carried out with echocardiography, ultrasound and clinical examination. Results: The defect diameters of the four cases were 2.0 mm, 2.7 mm, 2.5 mm and 1.5 mm respectively. The Duct-Occlude were successfully implanted in 3 cases of perimembranous VSD with the same type coil (OD[mm]7-3-6, windings 5-3-4) for each. One detachable coil (Cook) (5 x 5) was implanted in the remaining case. All cases had trivial residual shunt immediately after implantation which disappeared 24 hours later. Follow-up for 2 months to one year showed no coil displacement and secondary bacterial arteritis. No tricuspid and aortic regurgitation, no emboli, no endocarditis, and no arrhythmia were found. Conclusions: Coil closure of some small VSD with membranate part pseudo-ventricular aneurysm has good efficacy with the advantages of simple operation, less metal content and mini-invasion also applicable for infants. (authors)

  20. Identifying Medication Targets for Psychostimulant Addiction: Unraveling the Dopamine D3 Receptor Hypothesis

    Science.gov (United States)

    2016-01-01

    The dopamine D3 receptor (D3R) is a target for developing medications to treat substance use disorders. D3R-selective compounds with high affinity and varying efficacies have been discovered, providing critical research tools for cell-based studies that have been translated to in vivo models of drug abuse. D3R antagonists and partial agonists have shown especially promising results in rodent models of relapse-like behavior, including stress-, drug-, and cue-induced reinstatement of drug seeking. However, to date, translation to human studies has been limited. Herein, we present an overview and illustrate some of the pitfalls and challenges of developing novel D3R-selective compounds toward clinical utility, especially for treatment of cocaine abuse. Future research and development of D3R-selective antagonists and partial agonists for substance abuse remains critically important but will also require further evaluation and development of translational animal models to determine the best time in the addiction cycle to target D3Rs for optimal therapeutic efficacy. PMID:25826710

  1. Total and occluded residual gas content inside the nuclear fuel pellets

    International Nuclear Information System (INIS)

    Moura, Sergio C.; Fernandes, Carlos E.; Oliveira, Justine R.; Machado, Joyce F.; Guglielmo, Luisa M.; Bustillos, Oscar V.

    2009-01-01

    This work describes three techniques available to measure total and occluded residual gases inside the UO 2 nuclear fuel pellets. Hydrogen is the major gas compound inside these pellets, due to sintering fabrication process but Nitrogen is present as well, due to storage atmosphere fuel. The total and occluded residual gas content inside these pellets is a mandatory requirement in a quality control to assure the well function of the pellets inside the nuclear reactor. This work describes the Gas Extractor System coupled with mass spectrometry GES/MS, the Gas Extractor System coupled with gas chromatography GES/GC and the total Hydrogen / Nitrogen H/N analyzer as well. In the GES, occlude gases in the UO 2 pellets is determinate using a high temperature vacuum extraction system, in which the minimum limit of detection is in the range 0.002 cc/g. The qualitative and quantitative determination of the amount of gaseous components employs a mass spectrometry or a gas chromatography technique. The total Hydrogen / Nitrogen analyzer employ a thermal conductivity gas detector linked to a gaseous extractor furnace which has a detection limit is in the range 0.005 cc/g. The specification for the residual gas analyses in the nuclear fuel pellets is 0.03 cc/g, all techniques satisfy the requirement but not the nature of the gases due to reaction with the reactor cladding. The present work details the chemical reaction among Hydrogen / Nitrogen and nuclear reactor cladding. (author)

  2. Template occluded SBA-15: An effective dissolution enhancer for poorly water-soluble drug

    International Nuclear Information System (INIS)

    Fu Tingming; Guo Liwei; Le Kang; Wang Tianyao; Lu Jin

    2010-01-01

    The aim of the present work was to improve the dissolution rate of piroxicam by inclusion into template occluded SBA-15. Our strategy involves directly introducing piroxicam into as-prepared SBA-15 occluded with P123 (EO 20 PO 70 EO 20 ) by self assembling method in acetonitrile/methylene chloride mixture solution. Ultraviolet spectrometry experiment and thermogravimetric analysis-differential scanning calorimetry (TG-DSC) profiles show that the piroxicam and P123 contents in the inclusion compound are 12 wt% and 28 wt%, respectively. X-ray powder diffraction and DSC analysis reveal that the included piroxicam is arranged in amorphous form. N 2 adsorption-desorption experiment indicates that the piroxicam has been introduced to the mesopores instead of precipitating at the outside of the silica material. The inclusion compound was submitted to in vitro dissolution tests, the results show that the piroxicam dissolve from template occluded inclusion compound more rapidly, than these from the piroxicam crystalline and template removed samples in all tested conditions. Thus a facile method to improve the dissolution rate of poorly water-soluble drug was established, and this discovery opens a new avenue for the utilization of templates used for the synthesis of mesoporous materials.

  3. Interactive 3D visualization of structural changes in the brain of a person with corticobasal syndrome

    Directory of Open Access Journals (Sweden)

    Claudia eHänel

    2014-05-01

    Full Text Available The visualization of the progression of brain tissue loss, which occurs in neurodegenerative diseases like corticobasal syndrome (CBS, is an important prerequisite to understand the course and the causes of this neurodegenerative disorder. Common workflows for visual analysis are often based on single 2D sections since in 3D visualizations more internally situated structures may be occluded by structures near the surface. The reduction of dimensions from 3D to 2D allows for an holistic view onto internal and external structures, but results in a loss of spatial information. Here, we present an application with two 3D visualization designs to resolve these challenges. First, in addition to the volume changes, the semi-transparent anatomy is displayed with an anatomical section and cortical areas for spatial orientation. Second, the principle of importance-driven volume rendering is adapted to give an unrestricted line-of-sight to relevant structures by means of a frustum-like cutout. To strengthen the benefits of the 3D visualization, we decided to provide the application next to standard desktop environments in immersive virtual environments with stereoscopic viewing as well. This improves the depth perception in general and in particular for the second design. Thus, the application presented in this work allows for aneasily comprehensible visual analysis of the extent of brain degeneration and the corresponding affected regions.

  4. Recombination of H3+ and D3+ ions with electrons in low temperature plasma

    International Nuclear Information System (INIS)

    Glosik, J; Plasil, R.; Pysanenko, A.; Poterya, V.; Kudrna, P.; Zakouril, P.

    2002-01-01

    From the decaying plasma (stationary afterglow) in the mixture of He, Ar and H 2 (or D 2 ) we determined the overall recombination rate constant (α eff ) of the recombination of H 3 + and D 3 + ions with electrons at thermal energies. We observed dependence of recombination rate coefficients on partial pressure of hydrogen (and deuterium), which indicates that observed recombination is the three-body process proceeding most probably via formation of long lived intermediate state. From the obtained data we conclude that binary dissociative recombination of H 3 + and D 3 + ions with electrons is very slow with rate coefficient α DR -9 cm 3 s -1 and α DR -9 cm 3 s -1 , respectively. (author)

  5. Experimental validation of 3D reconstructed pin-power distributions in full-scale BWR fuel assemblies with partial length rods

    Energy Technology Data Exchange (ETDEWEB)

    Giust, F. D. [Axpo Kernenergie, Parkstrasse 23, CH-5401 Baden (Switzerland); Swiss Federal Inst. of Technology EPFL, CH-1015 Lausanne (Switzerland); Grimm, P. [Paul Scherrer Inst., CH-5232 Villigen (Switzerland); Chawla, R. [Paul Scherrer Inst., CH-5232 Villigen (Switzerland); Swiss Federal Inst. of Technology (EPFL), CH-1015 Lausanne (Switzerland)

    2012-07-01

    Total fission rate measurements have been performed on full-size BWR fuel assemblies of type SVEA-96 Optima2 in the framework of Phase III of the LWR-PROTEUS experimental program at the Paul Scherrer Inst.. This paper presents comparisons of calculated, nodal reconstructed, pin-wise total-fission rate distributions with experimental results. Radial comparisons have been performed for the three sections of the assembly (96, 92 and 84 fuel pins), while three-dimensional effects have been investigated at pellet-level for the two transition regions, i.e. the tips of the short (1/3) and long (2/3) partial length rods. The test zone has been modeled using two different code systems: HELIOS/PRESTO-2 and CASMO-5/SIMULATE-5. The first is presently used for core monitoring and design at the Leibstadt Nuclear Power Plant (KKL). The second represents the most recent generation of the widely applied CASMO/SIMULATE system. For representing the PROTEUS test-zone boundaries, Partial Current Ratios (PCRs) - derived from a 3D MCNPX model of the entire reactor - have been applied to the PRESTO-2 and SIMULATE-5 models in the form of 2- and 5-group diagonal albedo matrices, respectively. The MCNPX results have also served as a reference, high-order transport solution in the calculation/experiment comparisons. It is shown that the performance of the nodal methodologies in predicting the global distribution of the total-fission rate is very satisfactory. Considering the various radial comparisons, the standard deviations of the calculated/experimental (C/E) distributions do not exceed 1.9% for any of the three methodologies - PRESTO-2, SIMULATE-5 and MCNPX. For the three-dimensional comparisons at pellet-level, the corresponding standard deviations are 2.7%, 2.0% and 2.1%, respectively. (authors)

  6. Urgent surgical management for embolized occluder devices in childhood: single center experience

    Directory of Open Access Journals (Sweden)

    Gokaslan Gokhan

    2012-12-01

    Full Text Available Abstract Background In this study, we sought to analyze our experience in urgent surgical management for embolized cardiac septal and ductal occluder devices resulting from trans-catheter closure of atrial septal defect, ventricular septal defect and patent ductus arteriosus in childhood patient group. Methods We retrospectively reviewed 9 patients (aged 2–15 years who underwent urgent surgery due to cardiac septal and ductal occluder embolization between January 2007 and December 2010. Congenital defects were atrial septal defect (n = 6, ventricular septal defect (n = 1, and patent ductus arteriosus (n = 2. Risk factors for device embolization and urgent surgical management techniques for embolized device removal were discussed. Results Removal of embolized devices in all cases and repair of damaged tricuspid valve in 2 patients were performed. Inevitably, all congenital defects were closed or ligated up to the primary defect. Total circulator arrest necessitated in 1 patient with ascending aortic device embolization. All operations were completed successfully and no hospital mortality or morbidity was encountered. Conclusions Although closure of left to right shunting defects by percutaneous occluder devices has a lot of advantages, device embolization is still a major complication. If embolized device retrieval fails with percutaneous intervention attempts, surgical management is the only method to remove embolized devices. In this circumstance, to provide an uneventful perioperative course, urgent management strategies should be well planned.

  7. Occluded Brescia-Cimino Hemodialysis Fistulas: Endovascular Treatment with Both Brachial Arterial and Venous Access Using the Pull-Through Technique

    International Nuclear Information System (INIS)

    Miyayama, Shiro; Matsui, Osamu; Taki, Keiichi; Minami, Tetsuya; Shinmura, Rieko; Ito, Chiharu; Takamatsu, Shigeyuki; Kobayashi, Miki; Ushiogi, Yashuyuki

    2005-01-01

    We retrospectively evaluated the usefulness of both arterial and venous access with the pull-through technique in endovascular treatment of totally occluded Brescia-Cimino fistulas. We treated 26 patients (17 men, 9 women; age range 43-82 years, mean age 66 years) with occluded Brescia-Cimino fistulas. First, the occluded segment was traversed from the antegrade brachial arterial access using a microcatheter-guidewire system. Second, the vein was retrogradely punctured after confirmation of all diseased segments, and a 0.014- or 0.016-inch guidewire was pulled through the venous access when the occluded segment was long. All interventions including thrombolysis, thromboaspiration, angioplasty, and stent placement were performed via the venous access. The occlusion was successfully crossed via the brachial arterial access in 23 patients (88%). In 2 patients it was done from the venous approach. In the remaining patient it was not possible to traverse the occluded segment. The pull-through technique was successful in all 19 attempts. Clinical success was achieved in 96%, the primary patency rates at 6, 12, and 18 months were 83%, 78%, and 69%, the primary assisted patency rates were 92%, 92%, and 72%, and the secondary patency rates were 92%, 92%, and 92%, respectively. Minor complications in 5 patients included venous perforation in 2 (8%), venous rupture in 1 (4%), and regional hematoma in 2 (8%). Our study suggests that endovascular treatments with both arterial and venous access using the pull-through technique are highly effective in restoring function in totally occluded Brescia-Cimino fistulas

  8. Enzymic synthesis of indole-3-acetyl-1-O-beta-d-glucose. I. Partial purification and characterization of the enzyme from Zea mays

    Science.gov (United States)

    Leznicki, A. J.; Bandurski, R. S.

    1988-01-01

    The first enzyme-catalyzed reaction leading from indole-3-acetic acid (IAA) to the myo-inositol esters of IAA is the synthesis of indole-3-acetyl-1-O-beta-D-glucose from uridine-5'-diphosphoglucose (UDPG) and IAA. The reaction is catalyzed by the enzyme, UDPG-indol-3-ylacetyl glucosyl transferase (IAA-glucose-synthase). This work reports methods for the assay of the enzyme and for the extraction and partial purification of the enzyme from kernels of Zea mays sweet corn. The enzyme has an apparent molecular weight of 46,500 an isoelectric point of 5.5, and its pH optimum lies between 7.3 and 7.6. The enzyme is stable to storage at zero degrees but loses activity during column chromatographic procedures which can be restored only fractionally by addition of column eluates. The data suggest either multiple unknown cofactors or conformational changes leading to activity loss.

  9. Smaller calcite lattice deformation caused by occluded organic material in coccoliths than in mollusk shell

    DEFF Research Database (Denmark)

    Frølich, Simon; Sørensen, Henning Osholm; Hakim, Sepideh Sadat

    2015-01-01

    The growth and nucleation of biominerals are directed and affected by associated biological molecules. In this paper, we investigate the influence of occluded biomolecules on biogenic calcite from the coccolithophorid Pleurochrysis carterae and from chalk, a rock composed predominantly of fossil....... Two heating cycles allow us to differentiate the effects of thermal agitation and organic molecules. Single peak analysis and Rietveld refinement were combined to show significant differences resulting from the occluded biomolecules on the mineral phase in biogenic calcite in the mollusk shell...

  10. A unified computational model of the development of object unity, object permanence, and occluded object trajectory perception.

    Science.gov (United States)

    Franz, A; Triesch, J

    2010-12-01

    The perception of the unity of objects, their permanence when out of sight, and the ability to perceive continuous object trajectories even during occlusion belong to the first and most important capacities that infants have to acquire. Despite much research a unified model of the development of these abilities is still missing. Here we make an attempt to provide such a unified model. We present a recurrent artificial neural network that learns to predict the motion of stimuli occluding each other and that develops representations of occluded object parts. It represents completely occluded, moving objects for several time steps and successfully predicts their reappearance after occlusion. This framework allows us to account for a broad range of experimental data. Specifically, the model explains how the perception of object unity develops, the role of the width of the occluders, and it also accounts for differences between data for moving and stationary stimuli. We demonstrate that these abilities can be acquired by learning to predict the sensory input. The model makes specific predictions and provides a unifying framework that has the potential to be extended to other visual event categories. Copyright © 2010 Elsevier Inc. All rights reserved.

  11. Characterization of the hybrid RHD gene leading to the partial D category IIIc phenotype

    NARCIS (Netherlands)

    Beckers, E. A.; Faas, B. H.; Ligthart, P.; Simsek, S.; Overbeeke, M. A.; von dem Borne, A. E.; van Rhenen, D. J.; van der Schoot, C. E.

    1996-01-01

    A D-positive white woman was found to have produced alloanti-D leading to hemolytic disease of the newborn in her third D-positive child. The maternal D was identified as the partial D category IIIc antigen (DIIIc). The molecular basis of this phenotype was studied. The proposita and her relatives

  12. Template occluded SBA-15: An effective dissolution enhancer for poorly water-soluble drug

    Energy Technology Data Exchange (ETDEWEB)

    Fu Tingming, E-mail: futingming@gmail.com [College of Pharmacy, Nanjing University of Chinese Medicine, Nanjing 210029 (China); Guo Liwei; Le Kang; Wang Tianyao; Lu Jin [College of Pharmacy, Nanjing University of Chinese Medicine, Nanjing 210029 (China)

    2010-09-15

    The aim of the present work was to improve the dissolution rate of piroxicam by inclusion into template occluded SBA-15. Our strategy involves directly introducing piroxicam into as-prepared SBA-15 occluded with P123 (EO{sub 20}PO{sub 70}EO{sub 20}) by self assembling method in acetonitrile/methylene chloride mixture solution. Ultraviolet spectrometry experiment and thermogravimetric analysis-differential scanning calorimetry (TG-DSC) profiles show that the piroxicam and P123 contents in the inclusion compound are 12 wt% and 28 wt%, respectively. X-ray powder diffraction and DSC analysis reveal that the included piroxicam is arranged in amorphous form. N{sub 2} adsorption-desorption experiment indicates that the piroxicam has been introduced to the mesopores instead of precipitating at the outside of the silica material. The inclusion compound was submitted to in vitro dissolution tests, the results show that the piroxicam dissolve from template occluded inclusion compound more rapidly, than these from the piroxicam crystalline and template removed samples in all tested conditions. Thus a facile method to improve the dissolution rate of poorly water-soluble drug was established, and this discovery opens a new avenue for the utilization of templates used for the synthesis of mesoporous materials.

  13. Survey report on energy transportation systems which use hydrogen-occluding alloys; Suiso kyuzo gokin wo riyoshita energy yuso system chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-03-18

    Surveyed are systems which use hydrogen-occluding alloys for, e.g., storing and transporting hydrogen. This project is aimed at development of, and extraction of technical problems involved in, the concept of hydrogen energy transportation cycles for producing hydrogen in overseas countries by electrolysis using clean energy of hydraulic energy which are relatively cheap there; transporting hydrogen stored in a hydrogen-occluding alloy by sea to Japan; and converting it into electrical power to be delivered and used there. The surveyed items include current state of development/utilization of hydraulic power resources in overseas countries; pigeonholing the technical issues involved in the hydrogen transportation cycles, detailed studies thereon, and selection of the transportation cycles; current state of research, development and application of hydrogen-occluding alloys for various purposes; extraction of the elementary techniques for the techniques and systems for the hydrogen transportation systems which use hydrogen-occluding alloys; research themes of the future hydrogen-occluding alloys and the application techniques therefor, and research and development thereof; and legislative measures and safety. (NEDO)

  14. Hepatitis C virus non-structural protein 3 interacts with cytosolic 5'(3'-deoxyribonucleotidase and partially inhibits its activity.

    Directory of Open Access Journals (Sweden)

    Chiu-Ping Fang

    Full Text Available Infection with hepatitis C virus (HCV is etiologically involved in liver cirrhosis, hepatocellular carcinoma and B-cell lymphomas. It has been demonstrated previously that HCV non-structural protein 3 (NS3 is involved in cell transformation. In this study, a yeast two-hybrid screening experiment was conducted to identify cellular proteins interacting with HCV NS3 protein. Cytosolic 5'(3'-deoxyribonucleotidase (cdN, dNT-1 was found to interact with HCV NS3 protein. Binding domains of HCV NS3 and cellular cdN proteins were also determined using the yeast two-hybrid system. Interactions between HCV NS3 and cdN proteins were further demonstrated by co-immunoprecipitation and confocal analysis in cultured cells. The cellular cdN activity was partially repressed by NS3 protein in both the transiently-transfected and the stably-transfected systems. Furthermore, HCV partially repressed the cdN activity while had no effect on its protein expression in the systems of HCV sub-genomic replicons and infectious HCV virions. Deoxyribonucleotidases are present in most mammalian cells and involve in the regulation of intracellular deoxyribonucleotides pools by substrate cycles. Control of DNA precursor concentration is essential for the maintenance of genetic stability. Reduction of cdN activity would result in the imbalance of DNA precursor concentrations. Thus, our results suggested that HCV partially reduced the cdN activity via its NS3 protein and this may in turn cause diseases.

  15. Partially converted stereoscopic images and the effects on visual attention and memory

    Science.gov (United States)

    Kim, Sanghyun; Morikawa, Hiroyuki; Mitsuya, Reiko; Kawai, Takashi; Watanabe, Katsumi

    2015-03-01

    This study contained two experimental examinations of the cognitive activities such as visual attention and memory in viewing stereoscopic (3D) images. For this study, partially converted 3D images were used with binocular parallax added to a specific region of the image. In Experiment 1, change blindness was used as a presented stimulus. The visual attention and impact on memory were investigated by measuring the response time to accomplish the given task. In the change blindness task, an 80 ms blank was intersected between the original and altered images, and the two images were presented alternatingly for 240 ms each. Subjects were asked to temporarily memorize the two switching images and to compare them, visually recognizing the difference between the two. The stimuli for four conditions (2D, 3D, Partially converted 3D, distracted partially converted 3D) were randomly displayed for 20 subjects. The results of Experiment 1 showed that partially converted 3D images tend to attract visual attention and are prone to remain in viewer's memory in the area where moderate negative parallax has been added. In order to examine the impact of a dynamic binocular disparity on partially converted 3D images, an evaluation experiment was conducted that applied learning, distraction, and recognition tasks for 33 subjects. The learning task involved memorizing the location of cells in a 5 × 5 matrix pattern using two different colors. Two cells were positioned with alternating colors, and one of the gray cells was moved up, down, left, or right by one cell width. Experimental conditions was set as a partially converted 3D condition in which a gray cell moved diagonally for a certain period of time with a dynamic binocular disparity added, a 3D condition in which binocular disparity was added to all gray cells, and a 2D condition. The correct response rates for recognition of each task after the distraction task were compared. The results of Experiment 2 showed that the correct

  16. Feasibility and performance of novel software to quantify metabolically active volumes and 3D partial volume corrected SUV and metabolic volumetric products of spinal bone marrow metastases on 18F-FDG-PET/CT.

    Science.gov (United States)

    Torigian, Drew A; Lopez, Rosa Fernandez; Alapati, Sridevi; Bodapati, Geetha; Hofheinz, Frank; van den Hoff, Joerg; Saboury, Babak; Alavi, Abass

    2011-01-01

    Our aim was to assess feasibility and performance of novel semi-automated image analysis software called ROVER to quantify metabolically active volume (MAV), maximum standardized uptake value-maximum (SUV(max)), 3D partial volume corrected mean SUV (cSUV(mean)), and 3D partial volume corrected mean MVP (cMVP(mean)) of spinal bone marrow metastases on fluorine-18 fluorodeoxyglucose-positron emission tomography/computerized tomography ((18)F-FDG-PET/CT). We retrospectively studied 16 subjects with 31 spinal metastases on FDG-PET/CT and MRI. Manual and ROVER determinations of lesional MAV and SUV(max), and repeated ROVER measurements of MAV, SUV(max), cSUV(mean) and cMVP(mean) were made. Bland-Altman and correlation analyses were performed to assess reproducibility and agreement. Our results showed that analyses of repeated ROVER measurements revealed MAV mean difference (D)=-0.03±0.53cc (95% CI(-0.22, 0.16)), lower limit of agreement (LLOA)=-1.07cc, and upper limit of agreement (ULOA)=1.01cc; SUV(max) D=0.00±0.00 with LOAs=0.00; cSUV(mean) D=-0.01±0.39 (95% CI(-0.15, 0.13)), LLOA=-0.76, and ULOA=0.75; cMVP(mean) D=-0.52±4.78cc (95% CI(-2.23, 1.23)), LLOA=-9.89cc, and ULOA=8.86cc. Comparisons between ROVER and manual measurements revealed volume D= -0.39±1.37cc (95% CI (-0.89, 0.11)), LLOA=-3.08cc, and ULOA=2.30cc; SUV(max) D=0.00±0.00 with LOAs=0.00. Mean percent increase in lesional SUV(mean) and MVP(mean) following partial volume correction using ROVER was 84.25±36.00% and 84.45±35.94% , respectively. In conclusion, it is feasible to estimate MAV, SUV(max), cSUV(mean), and cMVP(mean) of spinal bone marrow metastases from (18)F-FDG-PET/CT quickly and easily with good reproducibility via ROVER software. Partial volume correction is imperative, as uncorrected SUV(mean) and MVP(mean) are significantly underestimated, even for large lesions. This novel approach has great potential for practical, accurate, and precise combined structural-functional PET

  17. MEASUREMENT OF THE B0 ---> D*- A+(1) BRANCHING FRACTION WITH PARTIALLY RECONSTRUCTED D*

    Energy Technology Data Exchange (ETDEWEB)

    Salvatore, Pasquale F

    2002-07-26

    The B{sup 0} {yields} D*{sup -} a{sub 1}{sup +} branching fraction has been measured with data collected by the BaBar experiment in 1999 and 2000 corresponding to a total integrated luminosity of 20.6 fb{sup -1}. Signal events have been selected using a partial reconstruction technique, in which only the a{sub 1}{sup +} and the slow pion ({pi}{sub s}) from the D*{sup -} decay are identified. A signal yield of 18400 {+-} 1200 events has been found, corresponding to a preliminary branching fraction of (1.20 {+-} 0.07(stat) {+-} 0.14(syst))%.

  18. Born-Infeld-Goldstone superfield actions for gauge-fixed D5- and D3-branes in 6d

    International Nuclear Information System (INIS)

    Ketov, Sergei V.

    1999-01-01

    The supersymmetric Born-Infeld actions describing gauge-fixed D-5- and D3-branes in ambient six-dimensional (6d) space-time are constructed in superspace. A new 6d action is the (1,0) supersymmetric extension of the 6d Born-Infeld action. It is related via dimensional reduction to another remarkable 4d action describing the N = 2 supersymmetric extension of the Born-Infeld-Nambu-Goto action with two real scalats. Both actions are the Goldstone actions associated with partial (((1)/(2))) spontaneous breaking of extended supersymmetry having 16 supercharges down to 8 supercharges. Both actions can be put into the 'non-linear sigma-model' form by using certain non-linear superfield constraints. The unbroken supersymmetry is always linearly realised in our construction

  19. Magmatic Systems in 3-D

    Science.gov (United States)

    Kent, G. M.; Harding, A. J.; Babcock, J. M.; Orcutt, J. A.; Bazin, S.; Singh, S.; Detrick, R. S.; Canales, J. P.; Carbotte, S. M.; Diebold, J.

    2002-12-01

    Multichannel seismic (MCS) images of crustal magma chambers are ideal targets for advanced visualization techniques. In the mid-ocean ridge environment, reflections originating at the melt-lens are well separated from other reflection boundaries, such as the seafloor, layer 2A and Moho, which enables the effective use of transparency filters. 3-D visualization of seismic reflectivity falls into two broad categories: volume and surface rendering. Volumetric-based visualization is an extremely powerful approach for the rapid exploration of very dense 3-D datasets. These 3-D datasets are divided into volume elements or voxels, which are individually color coded depending on the assigned datum value; the user can define an opacity filter to reject plotting certain voxels. This transparency allows the user to peer into the data volume, enabling an easy identification of patterns or relationships that might have geologic merit. Multiple image volumes can be co-registered to look at correlations between two different data types (e.g., amplitude variation with offsets studies), in a manner analogous to draping attributes onto a surface. In contrast, surface visualization of seismic reflectivity usually involves producing "fence" diagrams of 2-D seismic profiles that are complemented with seafloor topography, along with point class data, draped lines and vectors (e.g. fault scarps, earthquake locations and plate-motions). The overlying seafloor can be made partially transparent or see-through, enabling 3-D correlations between seafloor structure and seismic reflectivity. Exploration of 3-D datasets requires additional thought when constructing and manipulating these complex objects. As numbers of visual objects grow in a particular scene, there is a tendency to mask overlapping objects; this clutter can be managed through the effective use of total or partial transparency (i.e., alpha-channel). In this way, the co-variation between different datasets can be investigated

  20. Construction of occluded recombinant baculoviruses containing the full-length cry1Ab and cry1Ac genes from Bacillus thuringiensis

    Directory of Open Access Journals (Sweden)

    B.M. Ribeiro

    1998-06-01

    Full Text Available The administration of baculoviruses to insects for bioassay purposes is carried out, in most cases, by contamination of food surfaces with a known amount of occlusion bodies (OBs. Since per os infection is the natural route of infection, occluded recombinant viruses containing crystal protein genes (cry1Ab and cry1Ac from Bacillus thuringiensis were constructed for comparison with the baculovirus prototype Autographa californica nucleopolyhedrovirus (AcNPV. The transfer vector pAcUW2B was used for construction of occluded recombinant viruses. The transfer vector containing the crystal protein genes was cotransfected with linearized DNA from a non-occluded recombinant virus. The isolation of recombinant viruses was greatly facilitated by the reduction of background "wild type" virus and the increased proportion of recombinant viruses. Since the recombinant viruses containing full-length and truncated forms of the crystal protein genes did not seem to improve the pathogenicity of the recombinant viruses when compared with the wild type AcNPV, and in order to compare expression levels of the full-length crystal proteins produced by non-occluded and occluded recombinant viruses the full-length cry1Ab and cry1Ac genes were chosen for construction of occluded recombinant viruses. The recombinant viruses containing full-length and truncated forms of the crystal protein genes did not seem to improve its pathogenicity but the size of the larvae infected with the recombinant viruses was significantly smaller than that of larvae infected with the wild type virus.

  1. 18 CFR 270.302 - Occluded natural gas produced from coal seams.

    Science.gov (United States)

    2010-04-01

    ... produced from coal seams. 270.302 Section 270.302 Conservation of Power and Water Resources FEDERAL ENERGY... produced from coal seams. A person seeking a determination that natural gas is occluded natural gas produced from coal seams must file an application with the jurisdictional agency which contains the...

  2. Dopamine D1 and D3 receptor polypharmacology as a potential treatment approach for substance use disorder.

    Science.gov (United States)

    Galaj, Ewa; Ewing, Scott; Ranaldi, Robert

    2018-06-01

    In the search for efficacious pharmacotherapies to treat cocaine addiction much attention has been given to agents targeting dopamine D1 or D3 receptors because of the involvement of these receptors in drug-related behaviors. D1-like and D3 receptor partial agonists and antagonists have been shown to reduce drug reward, reinstatement of drug seeking and conditioned place preference in rodents and non-human primates. However, translation of these encouraging results to clinical settings has been limited due to a number of factors including toxicity, poor pharmacokinetic properties and extrapyramidal and sedative side effects. This review highlights the role of D1 and D3 receptors in drug reward and seeking, the discovery of D1-D3 heteromers and their potential as targets in the treatment of addiction. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Usefulness of high-resolution 3D multifusion medical imaging for preoperative planning in patients with posterior fossa hemangioblastoma: technical note.

    Science.gov (United States)

    Yoshino, Masanori; Nakatomi, Hirofumi; Kin, Taichi; Saito, Toki; Shono, Naoyuki; Nomura, Seiji; Nakagawa, Daichi; Takayanagi, Shunsaku; Imai, Hideaki; Oyama, Hiroshi; Saito, Nobuhito

    2017-07-01

    Successful resection of hemangioblastoma depends on preoperative assessment of the precise locations of feeding arteries and draining veins. Simultaneous 3D visualization of feeding arteries, draining veins, and surrounding structures is needed. The present study evaluated the usefulness of high-resolution 3D multifusion medical imaging (hr-3DMMI) for preoperative planning of hemangioblastoma. The hr-3DMMI combined MRI, MR angiography, thin-slice CT, and 3D rotated angiography. Surface rendering was mainly used for the creation of hr-3DMMI using multiple thresholds to create 3D models, and processing took approximately 3-5 hours. This hr-3DMMI technique was used in 5 patients for preoperative planning and the imaging findings were compared with the operative findings. Hr-3DMMI could simulate the whole 3D tumor as a unique sphere and show the precise penetration points of both feeding arteries and draining veins with the same spatial relationships as the original tumor. All feeding arteries and draining veins were found intraoperatively at the same position as estimated preoperatively, and were occluded as planned preoperatively. This hr-3DMMI technique could demonstrate the precise locations of feeding arteries and draining veins preoperatively and estimate the appropriate route for resection of the tumor. Hr-3DMMI is expected to be a very useful support tool for surgery of hemangioblastoma.

  4. Unconventional uses of septal occluder devices: Our experience reviewed

    Directory of Open Access Journals (Sweden)

    Neeraj Awasthy

    2015-03-01

    Conclusion: It is feasible in selected nonseptal defects, which traditionally have been subjected to surgical interventions, to treat successfully, non surgically with the use of non prototype occluder devices without significant complications. Conventionally these devices have not been recommended for closure of nonseptal defects but show good early outcome. Adequate sample size with good follow up data is necessary before concluding that it can be safe alternative to surgery on long term.

  5. DNA unwinding by ring-shaped T4 helicase gp41 is hindered by tension on the occluded strand.

    Science.gov (United States)

    Ribeck, Noah; Saleh, Omar A

    2013-01-01

    The replicative helicase for bacteriophage T4 is gp41, which is a ring-shaped hexameric motor protein that achieves unwinding of dsDNA by translocating along one strand of ssDNA while forcing the opposite strand to the outside of the ring. While much study has been dedicated to the mechanism of binding and translocation along the ssDNA strand encircled by ring-shaped helicases, relatively little is known about the nature of the interaction with the opposite, 'occluded' strand. Here, we investigate the interplay between the bacteriophage T4 helicase gp41 and the ss/dsDNA fork by measuring, at the single-molecule level, DNA unwinding events on stretched DNA tethers in multiple geometries. We find that gp41 activity is significantly dependent on the geometry and tension of the occluded strand, suggesting an interaction between gp41 and the occluded strand that stimulates the helicase. However, the geometry dependence of gp41 activity is the opposite of that found previously for the E. coli hexameric helicase DnaB. Namely, tension applied between the occluded strand and dsDNA stem inhibits unwinding activity by gp41, while tension pulling apart the two ssDNA tails does not hinder its activity. This implies a distinct variation in helicase-occluded strand interactions among superfamily IV helicases, and we propose a speculative model for this interaction that is consistent with both the data presented here on gp41 and the data that had been previously reported for DnaB.

  6. NASA-VOF3D, 3-D Transient, Free Surface, Incompressible Fluid Dynamic

    International Nuclear Information System (INIS)

    Torrey, M.D.

    1992-01-01

    1 - Description of program or function: NASA-VOF3D is a three- dimensional, transient, free surface, incompressible fluid dynamics program. It is specifically designed to calculate confined flows in a low gravity environment in which surface physics must be accurately treated. It allows multiple free surfaces with surface tension and wall adhesion and includes a partial cell treatment that allows curved boundaries and internal obstacles. Variable mesh spacing is permitted in all three coordinate directions. Boundary conditions available are rigid free-slip wall, rigid no-slip, wall, continuative, periodic, and specified pressure outflow boundary. 2 - Method of solution: NASA-VOF3D simulates incompressible flows with free surfaces using the volume-of-fluid (VOF) algorithm. This technique is based on the use of donor-acceptor differencing to track the free surface across an Eulerian grid. The free surfaces are treated by introducing a function defined to be unity at any point occupied by the fluid and zero elsewhere. The complete Navier- Stokes equations for an incompressible fluid are solved by finite differences with surface tension effects included. Wall adhesion may be included or neglected as a user option. The pressures (and velocities) are advanced in time throughout the computing mesh by either a conjugate residual method or the successive over-relaxation (SOR) method. The conjugate residual method is vectorized for the Cray and uses a scaled coefficient matrix. 3 - Restrictions on the complexity of the problem: NASA-VOF3D is restricted to cylindrical coordinate representation of the geometry. A three-dimensional wall-adhesion procedure is available only for straight-walled containers

  7. Comparison between 3D isotropic and 2D conventional MR arthrography for diagnosing rotator cuff tear and labral lesions: A meta-analysis.

    Science.gov (United States)

    Lee, Sun Hwa; Yun, Seong Jong; Jin, Wook; Park, So Young; Park, Ji Seon; Ryu, Kyung Nam

    2018-03-30

    Although 3D-isotropic MR arthrography has been characterized as a substitute imaging tool for rotator cuff tear (RCT) and labral lesions, it has not been commonly used in clinical practice because of controversy related to image blurring and indistinctness of structural edges. To perform a comparison of the diagnostic performance of 3D-isotropic MR arthrography and 2D-conventional MR arthrography for diagnosis of RCT (solely RCT, full/partial-thickness supraspinatus [SST]-infraspinatus [IST] tear, or subscapularis [SSc] tear) and labral lesions. Meta-analysis. Patients with shoulder pain. 3D-isotropic and 2D-conventional MR arthrography at 3.0T or 1.5T. PubMed and EMBASE were searched following the PRISMA guidelines. Bivariate modeling and hierarchical summary receiver operating characteristic modeling were performed to compare the overall diagnostic performance of 3D-isotropic and 2D-conventional MR arthrography. Multiple-subgroup analyses were performed for diagnosing RCT, full/partial-thickness SST-IST tear, SSc tear, and labral lesions. Meta-regression analyses were performed according to subject, study, and MR arthrography characteristics including 3D-isotropic sequences (turbo spine echo [TSE] vs. gradient echo [GRE]). Eleven studies (825 patients) were included. Overall, 3D-isotropic MR arthrography had similar pooled sensitivity (0.90 [95% CI, 0.87-0.93]) (P = 0.95) and specificity (0.92 [95% CI, 0.87-0.95]) (P = 0.99), relative to 2D-conventional MR arthrography (sensitivity, 0.91 [95% CI, 0.86-0.94]); specificity, 0.92 [95% CI, 0.87-0.95]). Multiple-subgroup analyses showed that sensitivities (P = 0.13-0.91) and specificities (P = 0.26-0.99) on 3D-isotropic MR arthrography for diagnosing RCT, full/partial-thickness SST-IST tear, SSC tear, and labral lesions were not significantly different from 2D-conventional MR arthrography. On meta-regression analysis, 3D-TSE sequence demonstrated higher sensitivity (P 3D-GRE for RCT and labral

  8. Coupling of the 3D neutron kinetic core model DYN3D with the CFD software ANSYS-CFX

    International Nuclear Information System (INIS)

    Grahn, Alexander; Kliem, Sören; Rohde, Ulrich

    2015-01-01

    Highlights: • Improved thermal hydraulic description of nuclear reactor cores. • Possibility of three-dimensional flow phenomena in the core, such as cross flow, flow reversal, flow around obstacles. • Simulation at higher spatial resolution as compared to system codes. - Abstract: This article presents the implementation of a coupling between the 3D neutron kinetic core model DYN3D and the commercial, general purpose computational fluid dynamics (CFD) software ANSYS-CFX. In the coupling approach, parts of the thermal hydraulic calculation are transferred to CFX for its better ability to simulate the three-dimensional coolant redistribution in the reactor core region. The calculation of the heat transfer from the fuel into the coolant remains with DYN3D, which incorporates well tested and validated heat transfer models for rod-type fuel elements. On the CFX side, the core region is modeled based on the porous body approach. The implementation of the code coupling is verified by comparing test case results with reference solutions of the DYN3D standalone version. Test cases cover mini and full core geometries, control rod movement and partial overcooling transients

  9. [Treatment of removable partial dentures. 2. Causes and consequences of a reduced occlusal system].

    Science.gov (United States)

    Witter, D J; Barèl, J C; de Baat, C; Keltjens, H M A M; Creugers, N H J

    2011-01-01

    The occlusal system is part of the orofacial system and consists of the maxillary and mandibular alveolar ridge and teeth which are occluding or not or the removable denture teeth. The most prevalent causes of loss of teeth are insufficient oral self care or inadequate professional oral healthcare service. A reduced dentition can be described in terms of diastemas in the anterior region and number of occluding pairs of (pre)molars, differentiated as interrupted or shortened dental arches. Characteristic of a healthy functional occlusal system are the absence of pathology and the possibility to practice all oral functions without inconvenience. The consequences of a reduced occlusal system may be overload and/or migration of teeth, mandibular instability, and impaired esthetics and chewing function. Morphological and functional alterations can be considered to be adaptations to changed situations or to be pathological. The distinction between adaptation and pathology cannot be sharply defined. If prosthetic replacement of teeth is needed, the trend is to avoid removable partial dentures.

  10. Area at risk and collateral circulation in a first acute myocardial infarction with occluded culprit artery. STEMI vs non-STEMI patients.

    Science.gov (United States)

    Figueras, Jaume; Otaegui, Imanol; Marti, Gerard; Domingo, Enric; Bañeras, Jordi; Barrabés, José A; Del Blanco, Bruno Garcia; Garcia-Dorado, David

    2018-05-15

    It is unclear why among patients with first acute myocardial infarction and an occluded culprit artery only some present ST segment elevation. In fact, there is no study that compares the angiographic area at risk and the collateral circulation in first NSTEMI vs STEMI patients. 205 patients admitted for myocardial infarction with occluded culprit artery were included, 132 STEMI and 73 NSTEMI. Demographic data, the area at risk determined by the BARI score and collateral supply by the Rentrop score from the 2 groups were compared. NSTEMI patients showed lower peak Tn I than STEMI in the overall group but also in the 3 subsets with different culprit arteries (p collaterals (Rentrop score ≥ 2, 1.82 vs 0.41, p collateral blood supply than STEMI patients in each of the 3 main culprit arteries. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. 3D Multifunctional Ablative Thermal Protection System

    Science.gov (United States)

    Feldman, Jay; Venkatapathy, Ethiraj; Wilkinson, Curt; Mercer, Ken

    2015-01-01

    NASA is developing the Orion spacecraft to carry astronauts farther into the solar system than ever before, with human exploration of Mars as its ultimate goal. One of the technologies required to enable this advanced, Apollo-shaped capsule is a 3-dimensional quartz fiber composite for the vehicle's compression pad. During its mission, the compression pad serves first as a structural component and later as an ablative heat shield, partially consumed on Earth re-entry. This presentation will summarize the development of a new 3D quartz cyanate ester composite material, 3-Dimensional Multifunctional Ablative Thermal Protection System (3D-MAT), designed to meet the mission requirements for the Orion compression pad. Manufacturing development, aerothermal (arc-jet) testing, structural performance, and the overall status of material development for the 2018 EM-1 flight test will be discussed.

  12. Long-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder

    Science.gov (United States)

    Behjati-Ardakani, Mostafa; Behjati-Ardakani, Mohammad-Amin; Hosseini, Seyed-Habibolla; Noori, Noormohammad

    2013-01-01

    Objective Patent ductus arteriosus (PDA) is one of the most frequently seen congenital heart diseases. Its closure is recommended because of the risk of infective endocardis, as well as morbidity and mortality in the long. The aim of this study was to assess the long term results of the transcatheter closure of PDA in infants using amplatzer duct occlude (ADO). Methods From May 2004 to September 2011, forty eight infants underwent transcatheter closure of PDA. A lateral or right anterior oblique view aortogram was done to locate PDA and to measure its size. Before discharge, repeat aortogram was performed to evaluate eventual residual shunt and to confirm the appropriate deployment of the ADO. Follow up evaluations were done with transthoracic echocardiography at discharge, 1 month, 6 months, 12 months and yearly thereafter. Findings The mean age of patients at procedure was 9.18±2.32 (range 3 to 12) months, mean weight 6.73±1.16 (range 4.5 to 10.1) kg. The PDA occluded completely in 20 out of the 48 patients. Twenty four patients had trivial or mild shunt and two patients had moderate residual shunt which disappeared in one patient within 24 hours and other patient with moderate shunt in 1 month. One patient (age 8 months) had mild LPA stenosis. The device emobolization occurred in two patients, immediately after the procedure in one and during night in the other patient Conclusion The long term results suggested that transcatheter closure of PDA using Amplatzer duct occluder is a safe and effective treatment in infants less than 1 year of age with minimal complications. PMID:24427494

  13. Salt-occluded zeolite waste forms: Crystal structures and transformability

    International Nuclear Information System (INIS)

    Richardson, J.W. Jr.

    1996-01-01

    Neutron diffraction studies of salt-occluded zeolite and zeolite/glass composite samples, simulating nuclear waste forms loaded with fission products, have revealed complex structures, with cations assuming the dual roles of charge compensation and occlusion (cluster formation). These clusters roughly fill the 6--8 angstrom diameter pores of the zeolites. Samples are prepared by equilibrating zeolite-A with complex molten Li, K, Cs, Sr, Ba, Y chloride salts, with compositions representative of anticipated waste systems. Samples prepared using zeolite 4A (which contains exclusively sodium cations) as starting material are observed to transform to sodalite, a denser aluminosilicate framework structure, while those prepared using zeolite 5A (sodium and calcium ions) more readily retain the zeolite-A structure. Because the sodalite framework pores are much smaller than those of zeolite-A, clusters are smaller and more rigorously confined, with a correspondingly lower capacity for waste containment. Details of the sodalite structures resulting from transformation of zeolite-A depend upon the precise composition of the original mixture. The enhanced resistance of salt-occluded zeolites prepared from zeolite 5A to sodalite transformation is thought to be related to differences in the complex chloride clusters present in these zeolite mixtures. Data relating processing conditions to resulting zeolite composition and structure can be used in the selection of processing parameters which lead to optimal waste forms

  14. See-through 3D technology for augmented reality

    Science.gov (United States)

    Lee, Byoungho; Lee, Seungjae; Li, Gang; Jang, Changwon; Hong, Jong-Young

    2017-06-01

    Augmented reality is recently attracting a lot of attention as one of the most spotlighted next-generation technologies. In order to get toward realization of ideal augmented reality, we need to integrate 3D virtual information into real world. This integration should not be noticed by users blurring the boundary between the virtual and real worlds. Thus, ultimate device for augmented reality can reconstruct and superimpose 3D virtual information on the real world so that they are not distinguishable, which is referred to as see-through 3D technology. Here, we introduce our previous researches to combine see-through displays and 3D technologies using emerging optical combiners: holographic optical elements and index matched optical elements. Holographic optical elements are volume gratings that have angular and wavelength selectivity. Index matched optical elements are partially reflective elements using a compensation element for index matching. Using these optical combiners, we could implement see-through 3D displays based on typical methodologies including integral imaging, digital holographic displays, multi-layer displays, and retinal projection. Some of these methods are expected to be optimized and customized for head-mounted or wearable displays. We conclude with demonstration and analysis of fundamental researches for head-mounted see-through 3D displays.

  15. Human hepatocytes loaded in 3D bioprinting generate mini-liver.

    Science.gov (United States)

    Zhong, Cheng; Xie, Hai-Yang; Zhou, Lin; Xu, Xiao; Zheng, Shu-Sen

    2016-10-01

    Because of an increasing discrepancy between the number of potential liver graft recipients and the number of organs available, scientists are trying to create artificial liver to mimic normal liver function and therefore, to support the patient's liver when in dysfunction. 3D printing technique meets this purpose. The present study was to test the feasibility of 3D hydrogel scaffolds for liver engineering. We fabricated 3D hydrogel scaffolds with a bioprinter. The biocompatibility of 3D hydrogel scaffolds was tested. Sixty nude mice were randomly divided into four groups, with 15 mice in each group: control, hydrogel, hydrogel with L02 (cell line HL-7702), and hydrogel with hepatocyte growth factor (HGF). Cells were cultured and deposited in scaffolds which were subsequently engrafted into livers after partial hepatectomy and radiation-induced liver damage (RILD). The engrafted tissues were examined after two weeks. The levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), albumin, total bilirubin, CYP1A2, CYP2C9, glutathione S-transferase (a-GST), and UDP-glucuronosyl transferase (UGT-2) were compared among the groups. Hematoxylin-eosin (HE) staining and immunohistochemistry of cKit and cytokeratin 18 (CK18) of engrafted tissues were evaluated. The survival time of the mice was also compared among the four groups. 3D hydrogel scaffolds did not impact the viability of cells. The levels of ALT, AST, albumin, total bilirubin, CYP1A2, CYP2C9, a-GST and UGT-2 were significantly improved in mice engrafted with 3D scaffold loaded with L02 compared with those in control and scaffold only (P<0.05). HE staining showed clear liver tissue and immunohistochemistry of cKit and CK18 were positive in the engrafted tissue. Mice treated with 3D scaffold+L02 cells had longer survival time compared with those in control and scaffold only (P<0.05). 3D scaffold has the potential of recreating liver tissue and partial liver functions and can be used in the

  16. Survey research report by the hydrogen occluding alloy utilization development committee; Suiso kyuzo gokin riyo kaihatsu iinkai chosa kenkyu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1985-03-01

    This report summarizes the FY 1984 survey research results, issued by the hydrogen occluding alloy utilization development committee. The basic property subcommittee is responsible for collecting published data related to the basic properties of metal halides as much as possible, and pigeonholing them to have the data which can contribute to development of the new alloys for basic researches and engineering applications of hydrogen occluding alloys. The subcommittee members have collected these data. The common theme subcommittee has planned to collect the P-C-T diagrams of the hydrogen occluding alloys and new alloys as much as possible, for the designs, development, production and system designs of the hydrogen occluding alloys. The P-C-T diagrams have been collected for a total of 340 types of alloys, which fall into the broad categories of Mg-based, TiFe-based, TiMn-based, other Ti-based, rare-earth-based, Zr-based, Ca-based and others. The analytical methods have been also investigated while collecting P-C-T diagrams. (NEDO)

  17. Higher-Order Neural Networks Applied to 2D and 3D Object Recognition

    Science.gov (United States)

    Spirkovska, Lilly; Reid, Max B.

    1994-01-01

    A Higher-Order Neural Network (HONN) can be designed to be invariant to geometric transformations such as scale, translation, and in-plane rotation. Invariances are built directly into the architecture of a HONN and do not need to be learned. Thus, for 2D object recognition, the network needs to be trained on just one view of each object class, not numerous scaled, translated, and rotated views. Because the 2D object recognition task is a component of the 3D object recognition task, built-in 2D invariance also decreases the size of the training set required for 3D object recognition. We present results for 2D object recognition both in simulation and within a robotic vision experiment and for 3D object recognition in simulation. We also compare our method to other approaches and show that HONNs have distinct advantages for position, scale, and rotation-invariant object recognition. The major drawback of HONNs is that the size of the input field is limited due to the memory required for the large number of interconnections in a fully connected network. We present partial connectivity strategies and a coarse-coding technique for overcoming this limitation and increasing the input field to that required by practical object recognition problems.

  18. 3d N=2 mirror symmetry, pq-webs and monopole superpotentials

    Energy Technology Data Exchange (ETDEWEB)

    Benvenuti, Sergio [International School of Advanced Studies (SISSA),via Bonomea 265, 34136 Trieste (Italy); INFN, Sezione di Trieste,Trieste (Italy); Pasquetti, Sara [Dipartimento di Fisica, Università di Milano-Bicocca,I-20126 Milano (Italy)

    2016-08-23

    D3 branes stretching between webs of (p,q) 5branes provide an interesting class of 3dN=2 theories. For generic pq-webs however the low energy field theory is not known. We use 3d mirror symmetry and Type IIB S-duality to construct Abelian gauge theories corresponding to D3 branes ending on both sides of a pq-web made of many coincident NS5’s intersecting one D5. These theories contain chiral monopole operators in the superpotential and enjoy a non trivial pattern of global symmetry enhancements. In the special case of the pq-web with one D5 and one NS5, the 3d low energy SCFT admits three dual formulations. This triality can be applied locally inside bigger quiver gauge theories. We prove our statements using partial mirror symmetry à la Kapustin-Strassler, showing the equality of the S{sub b}{sup 3} partition functions and studying the quantum chiral rings.

  19. MO-DE-210-06: Development of a Supercompounded 3D Volumetric Ultrasound Image Guidance System for Prone Accelerated Partial Breast Irradiation (APBI)

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, T; Hrycushko, B; Zhao, B; Jiang, S; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: For early-stage breast cancer, accelerated partial breast irradiation (APBI) is a cost-effective breast-conserving treatment. Irradiation in a prone position can mitigate respiratory induced breast movement and achieve maximal sparing of heart and lung tissues. However, accurate dose delivery is challenging due to breast deformation and lumpectomy cavity shrinkage. We propose a 3D volumetric ultrasound (US) image guidance system for accurate prone APBI Methods: The designed system, set beneath the prone breast board, consists of a water container, an US scanner, and a two-layer breast immobilization cup. The outer layer of the breast cup forms the inner wall of water container while the inner layer is attached to patient breast directly to immobilization. The US transducer scans is attached to the outer-layer of breast cup at the dent of water container. Rotational US scans in a transverse plane are achieved by simultaneously rotating water container and transducer, and multiple transverse scanning forms a 3D scan. A supercompounding-technique-based volumetric US reconstruction algorithm is developed for 3D image reconstruction. The performance of the designed system is evaluated with two custom-made gelatin phantoms containing several cylindrical inserts filled in with water (11% reflection coefficient between materials). One phantom is designed for positioning evaluation while the other is for scaling assessment. Results: In the positioning evaluation phantom, the central distances between the inserts are 15, 20, 30 and 40 mm. The distances on reconstructed images differ by −0.19, −0.65, −0.11 and −1.67 mm, respectively. In the scaling evaluation phantom, inserts are 12.7, 19.05, 25.40 and 31.75 mm in diameter. Measured inserts’ sizes on images differed by 0.23, 0.19, −0.1 and 0.22 mm, respectively. Conclusion: The phantom evaluation results show that the developed 3D volumetric US system can accurately localize target position and determine

  20. How to manage a case of aymptomatic thoraco-abdominal aortic aneurysm with occluded mesenteric arteries

    Directory of Open Access Journals (Sweden)

    Abhisekh Mohanty

    2015-12-01

    Full Text Available We report a unique case of a 57-year-old male having a suprarenal thoraco-abdominal aortic aneurysm which is extending till the origin of superior mesenteric artery (SMA. The origins of celiac artery and SMA were totally occluded and filled retrogradely through dense collateral vessels arising from the inferior mesenteric artery. Surprisingly, the patient was not having any symptoms related to mesenteric ischemia. We decided to use a conventional aortic aneurysm stent graft to repair it without revascularizing the occluded mesenteric arteries. After 1 month, CT aortogram was repeated which revealed a well-apposed stent graft with no endoleaks. He did not have any clinical signs and symptoms attributable to mesenteric ischemia.

  1. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder.

    Science.gov (United States)

    Bilici, Meki; Demir, Fikri; Akın, Alper; Türe, Mehmet; Balık, Hasan; Kuyumcu, Mahir

    2017-12-01

    The aim of this study was to evaluate the feasibility, efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with the Occlutech duct occluder (ODO) in children. We reviewed the clinical records of 71 patients who underwent percutaneous closure of PDA with an ODO between September 2014 and August 2016. The Occlutech duct occluder was applied to 71 patients during the study period (September 2014-August 2016), and the results were analyzed in this study. Forty-two of the patients were female and 29 male. The median age was 20.5 months (range, 6-194 months) and median weight was 16 kg (range, 6-68 kg). The PDA was classified as type A in 54 patients (76.1%), type E in 14 (19.7%), type C in 2 (2.8%) and type B in 1 (1.4%) based on the Krichenko classification. A standard ODO device was used for the transcatheter closure procedure in 66 patients and the long-shank ODO device in 5. In the echocardiographic measurement of PDA, the median smallest diameter was 2.7 mm (range, 1.5-7.0 mm), and in the angiographic measurement, the median smallest diameter was 2.5 mm (range, 1.5-6.5 mm). All 71 patients underwent successful PDA closure with the ODO. Angiography following the procedure showed complete closure in 47 patients (66.2%), mild residual shunt in 13 patients (18.3%) and a trivial shunt in 11 patients (15.5%). Color flow Doppler echocardiogpaphy at 24 h post-implantation showed that complete closure was achieved in 65 patients (91.5%), and 6 patients (8.5%) had mild residual shunt. All patients (100%) had complete closure at 30 days of follow-up. The results of this study showed that the Occlutech PDA occluder device is safe and effective in the closure of PDA. As the pulmonary artery side of the device is wider than the aortic side, protrusion toward the aortic side and embolization are prevented, but there is residual shunt in the early period, although this residual shunt disappeared after a few months.

  2. Depiction of the cranial nerves around the cavernous sinus by 3D reversed FISP with diffusion weighted imaging (3D PSIF-DWI)

    International Nuclear Information System (INIS)

    Ishida, Go; Oishi, Makoto; Jinguji, Shinya; Yoneoka, Yuichiro; Fujii, Yukihiko; Sato, Mitsuya

    2011-01-01

    The purpose of this study was to evaluate the anatomy of cranial nerves running in and around the cavernous sinus, we employed three-dimensional reversed fast imaging with steady-state precession (FISP) with diffusion weighted imaging (3D PSIF-DWI) on 3-T magnetic resonance (MR) system. After determining the proper parameters to obtain sufficient resolution of 3D PSIF-DWI, we collected imaging data of 20-side cavernous regions in 10 normal subjects. 3D PSIF-DWI provided high contrast between the cranial nerves and other soft tissues, fluid, and blood in all subjects. We also created volume-rendered images of 3D PSIF-DWI and anatomically evaluated the reliability of visualizing optic, oculomotor, trochlear, trigeminal, and abducens nerves on 3D PSIF-DWI. All 20 sets of cranial nerves were visualized and 12 trochlear nerves and 6 abducens nerves were partially identified. We also presented preliminary clinical experiences in two cases with pituitary adenomas. The anatomical relationship between the tumor and cranial nerves running in and around the cavernous sinus could be three-dimensionally comprehended by 3D PSIF-DWI and the volume-rendered images. In conclusion, 3D PSIF-DWI has great potential to provide high resolution 'cranial nerve imaging', which visualizes the whole length of the cranial nerves including the parts in the blood flow as in the cavernous sinus region. (author)

  3. [Depiction of the cranial nerves around the cavernous sinus by 3D reversed FISP with diffusion weighted imaging (3D PSIF-DWI)].

    Science.gov (United States)

    Ishida, Go; Oishi, Makoto; Jinguji, Shinya; Yoneoka, Yuichiro; Sato, Mitsuya; Fujii, Yukihiko

    2011-10-01

    To evaluate the anatomy of cranial nerves running in and around the cavernous sinus, we employed three-dimensional reversed fast imaging with steady-state precession (FISP) with diffusion weighted imaging (3D PSIF-DWI) on 3-T magnetic resonance (MR) system. After determining the proper parameters to obtain sufficient resolution of 3D PSIF-DWI, we collected imaging data of 20-side cavernous regions in 10 normal subjects. 3D PSIF-DWI provided high contrast between the cranial nerves and other soft tissues, fluid, and blood in all subjects. We also created volume-rendered images of 3D PSIF-DWI and anatomically evaluated the reliability of visualizing optic, oculomotor, trochlear, trigeminal, and abducens nerves on 3D PSIF-DWI. All 20 sets of cranial nerves were visualized and 12 trochlear nerves and 6 abducens nerves were partially identified. We also presented preliminary clinical experiences in two cases with pituitary adenomas. The anatomical relationship between the tumor and cranial nerves running in and around the cavernous sinus could be three-dimensionally comprehended by 3D PSIF-DWI and the volume-rendered images. In conclusion, 3D PSIF-DWI has great potential to provide high resolution "cranial nerve imaging", which visualizes the whole length of the cranial nerves including the parts in the blood flow as in the cavernous sinus region.

  4. An Infectious Pseudoaneurysm Caused by Ventricular Septal Defect Occluder in Patent Ductus Arteriosus Closure in a Two-Year-Old Child.

    Science.gov (United States)

    Li, Dingyang; Qiu, Qiu; Jin, Jing; Zhang, Changdong; Wang, Lijun; Zhang, Gangcheng

    2017-12-12

    We present a case of an infectious pseudoaneurysm after patent ductus arteriosus (PDA) closure with a ventricular septal defect (VSD) occluder in a two-year-old child. The aneurysm grew rapidly but was successfully removed in time and the patient survived. To our knowledge, this is the first report of an infectious pseudoaneurysm caused by VSD occluder in PDA closure.

  5. Characterization of vitamin D-deficient klotho(-/-) mice: do increased levels of serum 1,25(OH)2D3 cause disturbed calcium and phosphate homeostasis in klotho(-/-) mice?

    NARCIS (Netherlands)

    Woudenberg-Vrenken, T.E.; van der Eerden, B.C.; van der Kemp, A.W.; Leeuwen, J.P. van; Bindels, R.J.M.; Hoenderop, J.G.J.

    2012-01-01

    BACKGROUND: Klotho(-/-) mice display disturbed Ca(2+) and vitamin D homeostasis. Renal cytochrome p450 27b1 (Cyp27b1), the enzyme that catalyzes the hydrolysis to 1,25-dihydroxyvitamin D(3) (1,25(OH)(2)D(3)), is increased in klotho(-/-) mice, and a 1,25(OH)(2)D(3)-deficient diet partially normalized

  6. Impact of National Clinical Guideline Recommendations for Revascularization of Persistently Occluded Infarct-Related Arteries on Clinical Practice in the United States

    Science.gov (United States)

    Deyell, Marc W.; Buller, Christopher E.; Miller, Louis H.; Wang, Tracy Y.; Dai, David; Lamas, Gervasio A.; Srinivas, Vankeepuram S.; Hochman, Judith S.

    2013-01-01

    Background The Occluded Artery Trial (OAT) was a large, randomized controlled trial published in 2006 that demonstrated no benefit to routine percutaneous coronary intervention (PCI) of persistently totally occluded infarct-related arteries (IRA) identified a minimum of 24 hours (on calendar days 3–28) after myocardial infarction (MI). The purpose of this study was to determine the impact of OAT results and consequent change in guideline recommendations for PCI for treatment of persistently occluded IRAs. Methods We identified all patients enrolled in the CathPCI Registry, from 2005 to 2008, undergoing catheterization more than 24 hours after MI with a totally occluded native coronary artery and no major OAT exclusion criteria. We examined trends in monthly rates of PCI for occlusions after OAT publication and after guideline revisions. Because reporting of diagnostic catheterizations was not mandatory, we examined trends among hospitals in the highest quartile for reporting of diagnostic procedures. Results A total of 28 780 patient visits from 896 hospitals were included. Overall, we found no significant decline in the adjusted monthly rate of PCI of occlusions after publication of OAT (odds ratio [OR], 0.997; 95% confidence interval [CI], 0.989–1.006) or after guideline revisions (OR, 1.007; 95% CI, 0.992–1.022). Among hospitals consistently reporting diagnostic catheterizations, there was no significant decline after OAT publication (OR, 1.018; 95% CI, 0.995–1.042), and there was a trend toward decline after guideline revisions (OR, 0.963; 95% CI, 0.920–1.000). Conclusion These findings suggest that the results of OAT and consequent guideline revisions have not, to date, been fully incorporated into clinical practice in a large cross-section of hospitals in the United States. PMID:21747002

  7. Avaliação da liberação de NH4NO3 ocluido em zeólita 4A a partir de soluções salinas Assessment of release of NH4NO3 occluded zeolite 4A in solutions from salinas

    Directory of Open Access Journals (Sweden)

    Jardel Cavalcante Rolim de Almeida Andrade

    2010-01-01

    Full Text Available The zeolite 4A was used to evaluate the thermo kinetics parameters of NH4+ and NO3- ions occluded in its structure. The Osawa method for activation energy calculation was used to evaluate its thermal stability, and the results shown that the ion species interact differently depending on the zeolite pores, which determines the controlled release by its structure.

  8. Fundamentals of 3-D Neutron Kinetics and Current Status

    International Nuclear Information System (INIS)

    Aragones, J.M.

    2008-01-01

    This lecture includes the following topics: 1) A summary of the cell and lattice calculations used to generate the neutron reaction data for neutron kinetics, including the spectral and burnup calculations of LWR cells and fuel assembly lattices, and the main nodal kinetics parameters: mean neutron generation time and delayed neutron fraction; 2) the features of the advanced nodal methods for 3-D LWR core physics, including the treatment of partially inserted control rods, fuel assembly grids, fuel burnup and xenon and samarium transients, and excore detector responses, that are essential for core surveillance, axial offset control and operating transient analysis; 3) the advanced nodal methods for 3-D LWR core neutron kinetics (best estimate safety analysis, real-time simulation); and 4) example applications to 3-D neutron kinetics problems in transient analysis of PWR cores, including model, benchmark and operational transients without, or with simple, thermal-hydraulics feedback.

  9. Intelligent Open Data 3D Maps in a Collaborative Virtual World

    Directory of Open Access Journals (Sweden)

    Juho-Pekka Virtanen

    2015-05-01

    Full Text Available Three-dimensional (3D maps have many potential applications, such as navigation and urban planning. In this article, we present the use of a 3D virtual world platform Meshmoon to create intelligent open data 3D maps. A processing method is developed to enable the generation of 3D virtual environments from the open data of the National Land Survey of Finland. The article combines the elements needed in contemporary smart city concepts, such as the connection between attribute information and 3D objects, and the creation of collaborative virtual worlds from open data. By using our 3D virtual world platform, it is possible to create up-to-date, collaborative 3D virtual models, which are automatically updated on all viewers. In the scenes, all users are able to interact with the model, and with each other. With the developed processing methods, the creation of virtual world scenes was partially automated for collaboration activities.

  10. Low Levels of the 150-kD Insulin -Like Growth Factor Binding Protein 3 Ternary complex in Patients with Anorexia nervosa

    DEFF Research Database (Denmark)

    Støving, René K; Hangaard, Jørgen; Hagen, Claus

    2003-01-01

    women with AN at the time of diagnosis and after partial weight recovery and in 6 healthy age-matched women serving as controls. RESULTS: Patients with AN had low levels of ALS and IGFBP-3 contained in the 150-kD ternary complex and in the non-150-kD fraction. Following partial weight recovery, the 150......-kD IGFBP-3 ternary complex was fully normalized, despite only partial normalization of serum GH and IGF-I levels. Patients with AN did not present with IGFBP-3 proteolysis different from controls. CONCLUSION: The present data indicate a pivotal role of the nutritional status in the regulation...

  11. T-branes through 3d mirror symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Collinucci, Andrés; Giacomelli, Simone [Physique Théorique et Mathématique and International Solvay Institutes,Université Libre de Bruxelles,C.P. 231, 1050 Bruxelles (Belgium); Savelli, Raffaele [Institut de Physique Théorique, CEA Saclay,Orme de Merisiers, F-91191 Gif-sur-Yvette (France); Valandro, Roberto [Dipartimento di Fisica, Università di Trieste,Strada Costiera 11, 34151 Trieste (Italy); INFN, Sezione di Trieste,Via Valerio 2, 34127 Trieste (Italy); Abdus Salam International Centre for Theoretical Physics,Strada Costiera 11, 34151 Trieste (Italy)

    2016-07-19

    T-branes are exotic bound states of D-branes, characterized by mutually non-commuting vacuum expectation values for the worldvolume scalars. The M/F-theory geometry lifting D6/D7-brane configurations is blind to the T-brane data. In this paper, we make this data manifest, by probing the geometry with an M2-brane. We find that the effect of a T-brane is to deform the membrane worldvolume superpotential with monopole operators, which partially break the three-dimensional flavor symmetry, and reduce supersymmetry from N=4 to N=2. Our main tool is 3d mirror symmetry. Through this language, a very concrete framework is developed for understanding T-branes in M-theory. This leads us to uncover a new class of N=2 quiver gauge theories, whose Higgs branches mimic those of membranes at ADE singularities, but whose Coulomb branches differ from their N=4 counterparts.

  12. Indocyanine green videoangiography (ICGV)-guided surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS).

    Science.gov (United States)

    d'Avella, Elena; Volpin, Francesco; Manara, Renzo; Scienza, Renato; Della Puppa, Alessandro

    2013-03-01

    Maximal safe resection is the goal of correct surgical treatment of parasagittal meningiomas, and it is intimately related to the venous anatomy both near and directly involved by the tumor. Indocyanine green videoangiography (ICGV) has already been advocated as an intra-operative resourceful technique in brain tumor surgery for the identification of vessels. The aim of this study was to investigate the role of ICGV in surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS). In this study, we prospectively analyzed clinical, radiological and intra-operative findings of patients affected by parasagittal meningioma occluding the SSS, who underwent ICGV assisted-surgery. Radiological diagnosis of complete SSS occlusion was pre-operatively established in all cases. ICGV was performed before dural opening, before and during tumor resection, at the end of the procedure. Five patients were included in our study. In all cases, ICGV guided dural opening, tumor resection, and venous management. The venous collateral pathway was easily identified and preserved in all cases. Radical resection was achieved in four cases. Surgery was uneventful in all cases. Despite the small number of patients, our study shows that ICG videoangiography could play a crucial role in guiding surgery of parasagittal meningioma occluding the SSS. Further studies are needed to define the role of this technique on functional and oncological outcome of these patients.

  13. Front instabilities and invasiveness of simulated 3D avascular tumors.

    Directory of Open Access Journals (Sweden)

    Nikodem J Poplawski

    2010-05-01

    Full Text Available We use the Glazier-Graner-Hogeweg model to simulate three-dimensional (3D, single-phenotype, avascular tumors growing in an homogeneous tissue matrix (TM supplying a single limiting nutrient. We study the effects of two parameters on tumor morphology: a diffusion-limitation parameter defined as the ratio of the tumor-substrate consumption rate to the substrate-transport rate, and the tumor-TM surface tension. This initial model omits necrosis and oxidative/hypoxic metabolism effects, which can further influence tumor morphology, but our simplified model still shows significant parameter dependencies. The diffusion-limitation parameter determines whether the growing solid tumor develops a smooth (noninvasive or fingered (invasive interface, as in our earlier two-dimensional (2D simulations. The sensitivity of 3D tumor morphology to tumor-TM surface tension increases with the size of the diffusion-limitation parameter, as in 2D. The 3D results are unexpectedly close to those in 2D. Our results therefore may justify using simpler 2D simulations of tumor growth, instead of more realistic but more computationally expensive 3D simulations. While geometrical artifacts mean that 2D sections of connected 3D tumors may be disconnected, the morphologies of 3D simulated tumors nevertheless correlate with the morphologies of their 2D sections, especially for low-surface-tension tumors, allowing the use of 2D sections to partially reconstruct medically-important 3D-tumor structures.

  14. Learning of perceptual grouping for object segmentation on RGB-D data.

    Science.gov (United States)

    Richtsfeld, Andreas; Mörwald, Thomas; Prankl, Johann; Zillich, Michael; Vincze, Markus

    2014-01-01

    Object segmentation of unknown objects with arbitrary shape in cluttered scenes is an ambitious goal in computer vision and became a great impulse with the introduction of cheap and powerful RGB-D sensors. We introduce a framework for segmenting RGB-D images where data is processed in a hierarchical fashion. After pre-clustering on pixel level parametric surface patches are estimated. Different relations between patch-pairs are calculated, which we derive from perceptual grouping principles, and support vector machine classification is employed to learn Perceptual Grouping. Finally, we show that object hypotheses generation with Graph-Cut finds a globally optimal solution and prevents wrong grouping. Our framework is able to segment objects, even if they are stacked or jumbled in cluttered scenes. We also tackle the problem of segmenting objects when they are partially occluded. The work is evaluated on publicly available object segmentation databases and also compared with state-of-the-art work of object segmentation.

  15. 3D contrast-enhanced MR portography and direct X-ray portography: a correlation study

    International Nuclear Information System (INIS)

    Lin Jiang; Zhou Kangrong; Chen Zuang; Wang Jianhua; Yan Ziping; Wang Yixiang, J.

    2003-01-01

    Our objective was to compare 3D contrast-enhanced MR portography (3D CE MRP) on a 1.5-T MR imager with direct X-ray portography. Twenty-six consecutive patients underwent 3D CE MRP with in-plane resolution of 1.4 or 1.8 mm, and direct X-ray portography. The findings of these two methods were evaluated and compared. The main portal vein (PV), right PV with its anterior and posterior segmental branches, and left PV including its sagittal segment were shown clearly without diagnostic problem in all cases on MRP. The main PV appearance was accordant with MRP and X-ray. For intrahepatic PVs, the results agreed in 21 patients but disagreed in 5 patients. In 1 patient with a huge tumor in right liver, the right posterior PV was classified as occluded at MRP, but diffusely narrowed at X-ray. The findings of left intrahepatic PV were discordant in 3 patients with hepatocelluar carcinoma in the left lobe. The MRP demonstrated complete occlusion of the left PVs, whereas X-ray showed proximal narrowing and distal occlusion. In another patient with hepatocelluar carcinoma, a small non-occlusive thrombus involving the sagittal segment of the left PV was seen on MRP but not on X-ray. With demonstration of varices and portosystemic shunts, MRP showed results similar to those of X-ray, except one recanalized para-umbilical vein was excluded from the field of view at MRP due to the patient's limited ability of breathholding. The 3D CE MRP correlated well with direct X-ray portography in most cases, it was limited in distinguishing narrowing of an intrahepatic PV from occlusion, but it showed advantage in demonstrating small thrombus within PV. (orig.)

  16. Estimating the complexity of 3D structural models using machine learning methods

    Science.gov (United States)

    Mejía-Herrera, Pablo; Kakurina, Maria; Royer, Jean-Jacques

    2016-04-01

    Quantifying the complexity of 3D geological structural models can play a major role in natural resources exploration surveys, for predicting environmental hazards or for forecasting fossil resources. This paper proposes a structural complexity index which can be used to help in defining the degree of effort necessary to build a 3D model for a given degree of confidence, and also to identify locations where addition efforts are required to meet a given acceptable risk of uncertainty. In this work, it is considered that the structural complexity index can be estimated using machine learning methods on raw geo-data. More precisely, the metrics for measuring the complexity can be approximated as the difficulty degree associated to the prediction of the geological objects distribution calculated based on partial information on the actual structural distribution of materials. The proposed methodology is tested on a set of 3D synthetic structural models for which the degree of effort during their building is assessed using various parameters (such as number of faults, number of part in a surface object, number of borders, ...), the rank of geological elements contained in each model, and, finally, their level of deformation (folding and faulting). The results show how the estimated complexity in a 3D model can be approximated by the quantity of partial data necessaries to simulated at a given precision the actual 3D model without error using machine learning algorithms.

  17. The two C-terminal tyrosines stabilize occluded Na/K pump conformations containing Na or K ions.

    Science.gov (United States)

    Vedovato, Natascia; Gadsby, David C

    2010-07-01

    Interactions of the three transported Na ions with the Na/K pump remain incompletely understood. Na/K pump crystal structures show that the extended C terminus of the Na,K-adenosine triphosphatase (ATPase) alpha subunit directly contacts transmembrane helices. Deletion of the last five residues (KETYY in almost all Na/K pumps) markedly lowered the apparent affinity for Na activation of pump phosphorylation from ATP, a reflection of cytoplasmic Na affinity for forming the occluded E1P(Na3) conformation. ATPase assays further suggested that C-terminal truncations also interfere with low affinity Na interactions, which are attributable to extracellular effects. Because extracellular Na ions traverse part of the membrane's electric field to reach their binding sites in the Na/K pump, their movements generate currents that can be monitored with high resolution. We report here electrical measurements to examine how Na/K pump interactions with extracellular Na ions are influenced by C-terminal truncations. We deleted the last two (YY) or five (KESYY) residues in Xenopus laevis alpha1 Na/K pumps made ouabain resistant by either of two kinds of point mutations and measured their currents as 10-mM ouabain-sensitive currents in Xenopus oocytes after silencing endogenous Xenopus Na/K pumps with 1 microM ouabain. We found the low affinity inhibitory influence of extracellular Na on outward Na/K pump current at negative voltages to be impaired in all of the C-terminally truncated pumps. Correspondingly, voltage jump-induced transient charge movements that reflect pump interactions with extracellular Na ions were strongly shifted to more negative potentials; this signals a several-fold reduction of the apparent affinity for extracellular Na in the truncated pumps. Parallel lowering of Na affinity on both sides of the membrane argues that the C-terminal contacts provide important stabilization of the occluded E1P(Na3) conformation, regardless of the route of Na ion entry into the

  18. Long Term Effects of Percutaneous Coronary Intervention of the Totally Occluded Infarct-Related Artery in the Subacute Phase after Myocardial Infarction

    Science.gov (United States)

    Hochman, Judith S; Reynolds, Harmony R; Džavík, Vladimír; Buller, Christopher E; Ruzyllo, Witold; Sadowski, Zygmunt P; Maggioni, Aldo P; Carvalho, Antonio C; Rankin, James M.; White, Harvey D.; Goldberg, Suzanne; Forman, Sandra A; Mark, Daniel B; Lamas, Gervasio A

    2011-01-01

    Background Despite observations suggesting a benefit for late opening of occluded infarct-related arteries (IRA) post-myocardial infarction (MI), the Occluded Artery Trial (OAT) demonstrated no reduction in the composite of death, reinfarction and class IV heart failure (HF) over 2.9-yearmean follow-up. Follow-up was extended to determine whether late trends would favor either treatment group. Methods and Results OAT randomized 2201 stable patients with IRA occlusion >24hours (calendar days3-28) after MI. Severe inducible ischemia, rest angina, class III-IV HF and 3-vessel/left main disease were excluded. We conducted extended followed up of enrolled patients for an additional 3 years for the primary endpoint and angina (6-year median survivor follow up, longest 9 years, 12,234 patient-years).Rates of the primary endpoint (HR 1.06, 95% CI 0.88-1.28), fatal and nonfatal MI (HR 1.25, 95% CI 0.89-1.75), death and class IV HF were similar for PCI vs. MED groups. No interaction between baseline characteristics and treatment group on outcomes were observed. The vast majority of patients at each follow-up visit did not report angina. There was less angina in the PCI group through early in follow-up; by 3 years the between group difference was consistently <4 patients per 100 treated and not significantly different though there was a trend toward less angina in the PCI group at 3 and 5 years. The 7-year rate of PCI of the IRA during follow up was 11.1% for the PCI group compared to 14.7% for the MED group (HR 0.79, 95% CI 0.61-1.01. p=0.06). Conclusions Extended follow up of the OAT cohort provides robust evidence for no reduction of long-term rates of clinical events after routine PCI in stable patients with an occluded IRA and without severe inducible ischemia in the subacute phase post-MI. PMID:22025606

  19. A 3-D model of superfluid helium suitable for numerical analysis

    CERN Document Server

    Darve, C; Van Sciver, S W

    2009-01-01

    The two-fluid description is a very successful phenomenological representation of the properties of Helium II. A 3-D model suitable for numerical analysis based on the Landau-Khalatnikov description of Helium II is proposed. In this paper we introduce a system of partial differential equations that is both complete and consistent as well as practical, to be used for a 3-D solution of the flow of Helium II. The development of a 3-D numerical model for Helium II is motivated by the need to validate experimental results obtained by observing the normal component velocity distribution in a Helium II thermal counter-flow using the Particle Image Velocimetry (PIV) technique.

  20. 1,25D3 differentially suppresses bladder cancer cell migration and invasion through the induction of miR-101-3p.

    Science.gov (United States)

    Ma, Yingyu; Luo, Wei; Bunch, Brittany L; Pratt, Rachel N; Trump, Donald L; Johnson, Candace S

    2017-09-01

    Metastasis is the major cause of bladder cancer death. 1,25D 3 , the active metabolite of vitamin D, has shown anti-metastasis activity in several cancer model systems. However, the role of 1,25D 3 in migration and invasion in bladder cancer is unknown. To investigate whether 1,25D 3 affects migration and invasion, four human bladder cell lines with different reported invasiveness were selected: low-invasive T24 and 253J cells and highly invasive 253J-BV and TCCSUP cells. All of the four bladder cancer cells express endogenous and inducible vitamin D receptor (VDR) as examined by immunoblot analysis. 1,25D 3 had no effect on the proliferation of bladder cancer cells as assessed by MTT assay. In contrast, 1,25D 3 suppressed migration and invasion in the more invasive 253J-BV and TCCSUP cells, but not in the low-invasive 253J and T24 cells using "wound" healing, chemotactic migration and Matrigel-based invasion assays. 1,25D 3 promoted the expression of miR-101-3p and miR-126-3p in 253J-BV cells as examined by qRT-PCR. miR-101-3p inhibitor partially abrogated and pre-miR-101-3p further suppressed the inhibition of 1,25D 3 on migration and invasion in 253J-BV cells. Further, 1,25D 3 enhanced VDR recruitment to the promoter region of miR-101-3p using ChIP-qPCR assay. 1,25D 3 enhanced the promoter activity of miR-101-3p as evaluated by luciferase reporter assay. Taken together, 1,25D 3 suppresses bladder cancer cell migration and invasion in two invasive/migration competent lines but not in two less invasive/motile lines, which is partially through the induction of miR-101-3p expression at the transcriptional level.

  1. Analysis of the strong decays Ds3*(2860) → DK, D*K with QCD sum rules

    International Nuclear Information System (INIS)

    Wang, Zhi-Gang

    2016-01-01

    In this article, we assign the D s3 * (2860) to be a D-wave c anti s meson, study the hadronic coupling constants G D s3 * (2860)DK and G D s3 * (2860)D * K with the three-point QCD sum rules, and calculate the partial decay widths Γ(D s3 * (2860) → D * K) and Γ(D s3 * (2860) → DK). The predicted ratio R = Γ(D s3 * (2860) → D * K)/Γ(D s3 * (2860) → DK) = 0.57±0.38 cannot reproduce the experimental value R = Br(D sJ * (2860) → D * K)/Br(D sJ * (2860) → DK) = 1.10±0.15±0.19. (orig.)

  2. Partially massless higher-spin theory

    Energy Technology Data Exchange (ETDEWEB)

    Brust, Christopher [Perimeter Institute for Theoretical Physics,31 Caroline St. N, Waterloo, Ontario N2L 2Y5 (Canada); Hinterbichler, Kurt [CERCA, Department of Physics, Case Western Reserve University,10900 Euclid Ave, Cleveland, OH 44106 (United States)

    2017-02-16

    We study a generalization of the D-dimensional Vasiliev theory to include a tower of partially massless fields. This theory is obtained by replacing the usual higher-spin algebra of Killing tensors on (A)dS with a generalization that includes “third-order” Killing tensors. Gauging this algebra with the Vasiliev formalism leads to a fully non-linear theory which is expected to be UV complete, includes gravity, and can live on dS as well as AdS. The linearized spectrum includes three massive particles and an infinite tower of partially massless particles, in addition to the usual spectrum of particles present in the Vasiliev theory, in agreement with predictions from a putative dual CFT with the same symmetry algebra. We compute the masses of the particles which are not fixed by the massless or partially massless gauge symmetry, finding precise agreement with the CFT predictions. This involves computing several dozen of the lowest-lying terms in the expansion of the trilinear form of the enlarged higher-spin algebra. We also discuss nuances in the theory that occur in specific dimensions; in particular, the theory dramatically truncates in bulk dimensions D=3,5 and has non-diagonalizable mixings which occur in D=4,7.

  3. Partially massless higher-spin theory

    International Nuclear Information System (INIS)

    Brust, Christopher; Hinterbichler, Kurt

    2017-01-01

    We study a generalization of the D-dimensional Vasiliev theory to include a tower of partially massless fields. This theory is obtained by replacing the usual higher-spin algebra of Killing tensors on (A)dS with a generalization that includes “third-order” Killing tensors. Gauging this algebra with the Vasiliev formalism leads to a fully non-linear theory which is expected to be UV complete, includes gravity, and can live on dS as well as AdS. The linearized spectrum includes three massive particles and an infinite tower of partially massless particles, in addition to the usual spectrum of particles present in the Vasiliev theory, in agreement with predictions from a putative dual CFT with the same symmetry algebra. We compute the masses of the particles which are not fixed by the massless or partially massless gauge symmetry, finding precise agreement with the CFT predictions. This involves computing several dozen of the lowest-lying terms in the expansion of the trilinear form of the enlarged higher-spin algebra. We also discuss nuances in the theory that occur in specific dimensions; in particular, the theory dramatically truncates in bulk dimensions D=3,5 and has non-diagonalizable mixings which occur in D=4,7.

  4. Efficacy and safety of balloon-occluded retrograde transvenous obliteration with sodium tetradecyl sulfate liquid sclerotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Park, Sang Woo; Kwon, So Young; Cheo, Won Hyeok; Cheon, Young Koog; Shim, Chan Sup; Lee, Tae Yoon; Kim, Jeong Han [Digestive Disease Center, Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    To evaluate the efficacy and safety of balloon-occluded retrograde transvenous obliteration (BRTO) with sodium tetradecyl sulfate (STS) liquid sclerotherapy of gastric varices. Between February 2012 and August 2014, STS liquid sclerotherapy was performed in 17 consecutive patients (male:female = 8:9; mean age 58.6 years, range 44-86 years) with gastric varices. Retrograde venography was performed after occlusion of the gastrorenal shunt using a balloon catheter and embolization of collateral draining veins using coils or gelfoam pledgets, to evaluate the anatomy of the gastric varices. We prepared 2% liquid STS by mixing 3% STS and contrast media in a ratio of 2:1. A 2% STS solution was injected into the gastric varices until minimal filling of the afferent portal vein branch was observed (mean 19.9 mL, range 6-33 mL). Patients were followed up using computed tomography (CT) or endoscopy. Technical success was achieved in 16 of 17 patients (94.1%). The procedure failed in one patient because the shunt could not be occluded due to the large diameter of gastrorenal shunt. Complete obliteration of gastric varices was observed in 15 of 16 patients (93.8%) with follow-up CT or endoscopy. There was no rebleeding after the procedure. There was no procedure-related mortality. BRTO using STS liquid can be a safe and useful treatment option in patients with gastric varices.

  5. Oxygen partial pressure effects on the magnetron sputtered WO3 films

    International Nuclear Information System (INIS)

    Muğlu, G Merhan; Gür, E

    2016-01-01

    Electrochromism is changing color of a substance in response to the applied an external electric field and the phenomenon is reversible. WO 3 is very attractive material due to its electrochromic properties as well as it is also attractive for many different applications such as gas sensors, phosphorous screen, textile, glass industry. In this study, it is aimed to provide optimization of the optical and structural characteristics of WO 3 by changing the growth parameters mainly the oxygen partial pressure. The partial pressure of oxygen was changed with increments of 0.7 mTorr. For the analysis, X-ray Diffraction (XRD), absorption, Raman spectroscopy measurements were used. When O 2 gas increased, peaks belong to the WO 3 was observed in XRD patterns at the 2 theta angles of 23.0, 11.0, 23.5 and 28.5 angles corresponding to the (002), (020) and (220) planes, respectively. This shows that there is a significant effect of increasing O 2 partial pressure in the formation of WO 3 films. The bandgap energy of the WO 3 thin films are found to be around 3.0 eV. Raman measurements showed vibrational modes of W-O-W stretching and bending modes which shows small shifts depending on the partial pressures of the O 2 . Obtained results indicated that better crystal structure is obtained with higher O 2 gas partial pressure. (paper)

  6. Case study: Beauty and the Beast 3D: benefits of 3D viewing for 2D to 3D conversion

    Science.gov (United States)

    Handy Turner, Tara

    2010-02-01

    From the earliest stages of the Beauty and the Beast 3D conversion project, the advantages of accurate desk-side 3D viewing was evident. While designing and testing the 2D to 3D conversion process, the engineering team at Walt Disney Animation Studios proposed a 3D viewing configuration that not only allowed artists to "compose" stereoscopic 3D but also improved efficiency by allowing artists to instantly detect which image features were essential to the stereoscopic appeal of a shot and which features had minimal or even negative impact. At a time when few commercial 3D monitors were available and few software packages provided 3D desk-side output, the team designed their own prototype devices and collaborated with vendors to create a "3D composing" workstation. This paper outlines the display technologies explored, final choices made for Beauty and the Beast 3D, wish-lists for future development and a few rules of thumb for composing compelling 2D to 3D conversions.

  7. Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements.

    Science.gov (United States)

    Coene, A; Crevecoeur, G; Leliaert, J; Dupré, L

    2015-09-01

    Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of larger volumes can be

  8. Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements

    International Nuclear Information System (INIS)

    Coene, A.; Crevecoeur, G.; Dupré, L.; Leliaert, J.

    2015-01-01

    Purpose: Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. Methods: To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. Results: The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of

  9. Paracousti-UQ: A Stochastic 3-D Acoustic Wave Propagation Algorithm.

    Energy Technology Data Exchange (ETDEWEB)

    Preston, Leiph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    Acoustic full waveform algorithms, such as Paracousti, provide deterministic solutions in complex, 3-D variable environments. In reality, environmental and source characteristics are often only known in a statistical sense. Thus, to fully characterize the expected sound levels within an environment, this uncertainty in environmental and source factors should be incorporated into the acoustic simulations. Performing Monte Carlo (MC) simulations is one method of assessing this uncertainty, but it can quickly become computationally intractable for realistic problems. An alternative method, using the technique of stochastic partial differential equations (SPDE), allows computation of the statistical properties of output signals at a fraction of the computational cost of MC. Paracousti-UQ solves the SPDE system of 3-D acoustic wave propagation equations and provides estimates of the uncertainty of the output simulated wave field (e.g., amplitudes, waveforms) based on estimated probability distributions of the input medium and source parameters. This report describes the derivation of the stochastic partial differential equations, their implementation, and comparison of Paracousti-UQ results with MC simulations using simple models.

  10. Medication Discovery for Addiction: Translating the Dopamine D3 Receptor Hypothesis

    Science.gov (United States)

    Newman, Amy Hauck; Blaylock, Brandi L.; Nader, Michael A.; Bergman, Jack; Sibley, David R.; Skolnick, Phil

    2013-01-01

    The dopamine D3 receptor (D3R) has been investigated as a potential target for medication development to treat substance use disorders (SUDs) with a particular focus on cocaine and methamphetamine. Currently, there are no approved medications to treat cocaine and methamphetamine addiction and thus developing pharmacotherapeutics to compliment existing behavioral strategies is a fundamental goal. Novel compounds with high affinity and D3R selectivity have been evaluated in numerous animal models of drug abuse and favorable outcomes in nonhuman primate models of self-administration and relapse have provided compelling evidence to advance these agents into the clinic. One approach is to repurpose drugs that share the D3R mechanism and already have clinical utility, and to this end buspirone has been identified as a viable candidate for clinical trials. A second, but substantially more resource intensive and risky approach involves the development of compounds that exclusively target D3R, such as GSK598809 and PG 619. Clinical investigation of these drugs or other novel D3R-selective agents will provide a better understanding of the role D3R plays in addiction and whether or not antagonists or partial agonists that are D3R selective are effective in achieving abstinence in this patient population. PMID:22781742

  11. Analysis of the strong decays Ds3 *(2860) → DK, D*K with QCD sum rules

    Science.gov (United States)

    Wang, Zhi-Gang

    2016-10-01

    In this article, we assign the D_{s3}^{ast}(2860) to be a D-wave c bar{s} meson, study the hadronic coupling constants G_{D_{s3}^{ast}(2860)DK} and G_{D_{s3}^{ast} (2860)D^{ast}K} with the three-point QCD sum rules, and calculate the partial decay widths Γ (D_{s3}^{ast} (2860) → D^{ast}K) and Γ (D_{s3}^{ast}(2860) → DK) . The predicted ratio R = Γ (D_{s3}^{ast} (2860)→ D^{ast}K)/Γ (D_{s3}^{ast} (2860)→ DK) = 0.57± 0.38 cannot reproduce the experimental value R = Br(D_{sJ}^{ast} (2860)→ D^{ast}K)/Br (D_{sJ}^{ast} (2860)→ DK) = 1.10 ± 0.15 ± 0.19.

  12. 3D reconstruction for partial data electrical impedance tomography using a sparsity prior

    DEFF Research Database (Denmark)

    Garde, Henrik; Knudsen, Kim

    2015-01-01

    of the conductivity is used to improve reconstructions for the partial data problem with Cauchy data measured only on a subset of the boundary. A sparsity prior is enforced using the ℓ1 norm in the penalty term of a Tikhonov functional, and spatial prior information is incorporated by applying a spatially distributed...

  13. Effect of non-Newtonian characteristics of blood on magnetic particle capture in occluded blood vessel

    Science.gov (United States)

    Bose, Sayan; Banerjee, Moloy

    2015-01-01

    Magnetic nanoparticles drug carriers continue to attract considerable interest for drug targeting in the treatment of cancer and other pathological conditions. Magnetic carrier particles with surface-bound drug molecules are injected into the vascular system upstream from the desired target site, and are captured at the target site via a local applied magnetic field. Herein, a numerical investigation of steady magnetic drug targeting (MDT) using functionalized magnetic micro-spheres in partly occluded blood vessel having a 90° bent is presented considering the effects of non-Newtonian characteristics of blood. An Eulerian-Lagrangian technique is adopted to resolve the hemodynamic flow and the motion of the magnetic particles in the flow using ANSYS FLUENT. An implantable infinitely long cylindrical current carrying conductor is used to create the requisite magnetic field. Targeted transport of the magnetic particles in a partly occluded vessel differs distinctly from the same in a regular unblocked vessel. Parametric investigation is conducted and the influence of the insert configuration and its position from the central plane of the artery (zoffset), particle size (dp) and its magnetic property (χ) and the magnitude of current (I) on the "capture efficiency" (CE) is reported. Analysis shows that there exists an optimum regime of operating parameters for which deposition of the drug carrying magnetic particles in a target zone on the partly occluded vessel wall can be maximized. The results provide useful design bases for in vitro set up for the investigation of MDT in stenosed blood vessels.

  14. Fusion of Terrestrial and Airborne Laser Data for 3D modeling Applications

    Science.gov (United States)

    Mohammed, Hani Mahmoud

    This thesis deals with the 3D modeling phase of the as-built large BIM projects. Among several means of BIM data capturing, such as photogrammetric or range tools, laser scanners have been one of the most efficient and practical tool for a long time. They can generate point clouds with high resolution for 3D models that meet nowadays' market demands. The current 3D modeling projects of as-built BIMs are mainly focused on using one type of laser scanner data, such as Airborne or Terrestrial. According to the literatures, no significant (few) efforts were made towards the fusion of heterogeneous laser scanner data despite its importance. The importance of the fusion of heterogeneous data arises from the fact that no single type of laser data can provide all the information about BIM, especially for large BIM projects that are existing on a large area, such as university buildings, or Heritage places. Terrestrial laser scanners are able to map facades of buildings and other terrestrial objects. However, they lack the ability to map roofs or higher parts in the BIM project. Airborne laser scanner on the other hand, can map roofs of the buildings efficiently and can map only small part of the facades. Short range laser scanners can map the interiors of the BIM projects, while long range scanners are used for mapping wide exterior areas in BIM projects. In this thesis the long range laser scanner data obtained in the Stop-and-Go mapping mode, the short range laser scanner data, obtained in a fully static mapping mode, and the airborne laser data are all fused together to bring a complete effective solution for a large BIM project. Working towards the 3D modeling of BIM projects, the thesis framework starts with the registration of the data, where a new fast automatic registration algorithm were developed. The next step is to recognize the different objects in the BIM project (classification), and obtain 3D models for the buildings. The last step is the development of an

  15. [Percutaneous closure of ductus arteriosus and muscular ventricular defect with amplatzer occluder in a patient with severe pulmonary hypertension].

    Science.gov (United States)

    García-Montes, José Antonio; Zabal Cerdeira, Carlos; Calderón-Colmenero, Juan; Espínola, Nilda; Fernández de la Reguera, Guillermo; Buendía Hernández, Alfonso

    2005-01-01

    Surgical treatment of multiple muscular ventricular septal defects with associated lesions and severe pulmonary hypertension has a high morbility and mortality. Closure of these defects by the Amplatzer muscular VSD occluder is an alternative to surgery, avoiding the need of cardiopulmonary bypass. We present the case of a 38 year-old woman with signs of heart failure in NYHA functional class IV, with two muscular ventricular septal defects, patent ductus arteriosus and severe pulmonary hypertension, that were treated with three Amplatzer muscular VSD occluders, with significant reduction of pulmonary pressure and functional class improvement.

  16. Robust automatic high resolution segmentation of SOFC anode porosity in 3D

    DEFF Research Database (Denmark)

    Jørgensen, Peter Stanley; Bowen, Jacob R.

    2008-01-01

    Routine use of 3D characterization of SOFCs by focused ion beam (FIB) serial sectioning is generally restricted by the time consuming task of manually delineating structures within each image slice. We apply advanced image analysis algorithms to automatically segment the porosity phase of an SOFC...... anode in 3D. The technique is based on numerical approximations to partial differential equations to evolve a 3D surface to the desired phase boundary. Vector fields derived from the experimentally acquired data are used as the driving force. The automatic segmentation compared to manual delineation...... reveals and good correspondence and the two approaches are quantitatively compared. It is concluded that the. automatic approach is more robust, more reproduceable and orders of magnitude quicker than manual segmentation of SOFC anode porosity for subsequent quantitative 3D analysis. Lastly...

  17. Homo sapiens natriuretic peptide precursor type C (NPPC) mRNA,partial cds and 3' UTR.

    OpenAIRE

    Landi, Stefano; Melaiu, Ombretta; Cabiati, Manuela; Landi, Debora; Caselli, Chiara; Prescimone, Tommaso; Giannessi, Daniela; Gemignani, Federica; Del Ry, Silvia

    2010-01-01

    LOCUS HQ419060 318 bp mRNA linear PRI 24-NOV-2010 DEFINITION Homo sapiens natriuretic peptide precursor type C (NPPC) mRNA, partial cds and 3' UTR. ACCESSION HQ419060 VERSION HQ419060.1 GI:312261407 KEYWORDS . SOURCE Homo sapiens (human) ORGANISM Homo sapiens Eukaryota; Metazoa; Chordata; Craniata; Vertebrata; Euteleostomi; Mammalia; Eutheria; Euarchontoglires; Primates; Haplorrhini; Catarrhini; Hominidae; Homo. REFERENCE 1 (bases 1 to 318) AUTHORS Landi,S., Melaiu,O., Cabiati,M., Landi,D., C...

  18. Demonstration of partial pitch 2-bladed wind turbine

    DEFF Research Database (Denmark)

    Kim, Taeseong; Zahle, Frederik; Troldborg, Niels

    -sections on the blade as well as fully resolved rotor simulations, and finally simulations coupling HAWC2 with EllipSys3D, investigating the behaviors of the rotor at standstill, has been performed. For the WP3, the state-of-the art aeroelastic analysis tool, HAWC2, has been updated in order to consider the partial......This is the final report for the EUDP project performed from January 2012 to December 2015. The main objective for the project was to demonstrate the potential of the partial pitch two-bladed (PP-2B) technology. DTU Wind Energy took a responsibility for three workpackages (WPs) among 6 WPs which...... were aerodynamic evaluation of partial pitch technology (WP2), aeroelastic analysis of two-bladed turbine (WP3) and On-site testing (WP4). For the WP2, a comprehensive set of 3D CFD simulations including the gap between inner and outer part of the blade and vortex generators (VGs) of both cross...

  19. Long term results of balloon-occluded retrograde transvenous obliteration for portosystemic shunt encephalopathy in patients with liver cirrhosis and portal hypertension.

    Science.gov (United States)

    Inoue, Hiroto; Emori, Keigo; Toyonaga, Atsushi; Oho, Kazuhiko; Kumamoto, Masafumi; Haruta, Tsuyoshi; Mitsuyama, Keiichi; Tsuruta, Osamu; Sata, Michio

    2014-01-01

    This study examined 19 patients with portosystemic shunt encephalopathy caused by a splenorenal shunt (SRS), which was treated with balloon-occluded retrograde transvenous obliteration (B-RTO). Long-term treatment outcomes were evaluated based on hepatic functional reserve and vital prognosis. Encephalopathy improved in all patients after shunt embolization and closure. Albumin, serum ammonia, and the Child-Pugh score, a measure of liver function, were significantly improved 3 years after B-RTO, and exacerbation of damage to liver function was avoided (pliver failure and two patients from hepatocellular carcinoma. Patients had a poor prognosis if their albumin levels were less than 2.8 mg / dL before B-RTO (pEncephalopathy patients had complete response to B-RTO, but long-term prognosis was affected by hepatic functional reserve before B-RTO and by concurrent hepatocellular carcinoma. The results of this study suggest that in patients with SRS, it is important to perform B-RTO at an early stage when the hepatic functional reserve is still satisfactory.

  20. Refined 3d-3d correspondence

    Energy Technology Data Exchange (ETDEWEB)

    Alday, Luis F.; Genolini, Pietro Benetti; Bullimore, Mathew; Loon, Mark van [Mathematical Institute, University of Oxford, Andrew Wiles Building,Radcliffe Observatory Quarter, Woodstock Road, Oxford, OX2 6GG (United Kingdom)

    2017-04-28

    We explore aspects of the correspondence between Seifert 3-manifolds and 3d N=2 supersymmetric theories with a distinguished abelian flavour symmetry. We give a prescription for computing the squashed three-sphere partition functions of such 3d N=2 theories constructed from boundary conditions and interfaces in a 4d N=2{sup ∗} theory, mirroring the construction of Seifert manifold invariants via Dehn surgery. This is extended to include links in the Seifert manifold by the insertion of supersymmetric Wilson-’t Hooft loops in the 4d N=2{sup ∗} theory. In the presence of a mass parameter for the distinguished flavour symmetry, we recover aspects of refined Chern-Simons theory with complex gauge group, and in particular construct an analytic continuation of the S-matrix of refined Chern-Simons theory.

  1. A Randomized Controlled Trial of Two Semi-Occluded Vocal Tract Voice Therapy Protocols

    Science.gov (United States)

    Kapsner-Smith, Mara R.; Hunter, Eric J.; Kirkham, Kimberly; Cox, Karin; Titze, Ingo R.

    2015-01-01

    Purpose: Although there is a long history of use of semi-occluded vocal tract gestures in voice therapy, including phonation through thin tubes or straws, the efficacy of phonation through tubes has not been established. This study compares results from a therapy program on the basis of phonation through a flow-resistant tube (FRT) with Vocal…

  2. 3D gadolinium-enhanced MRI venography: Evaluation of central chest veins and impact on patient management

    International Nuclear Information System (INIS)

    Oxtoby, J.W.; Widjaja, E.; Gibson, K.M.; Uzoka, K.

    2001-01-01

    AIM: To assess the value of a simplified 3D gadolinium-enhanced magnetic resonance imaging (MRI) venography for central chest veins. MATERIALS AND METHODS: In this retrospective study of 24 patients, the MRI findings and medical records were reviewed to determine whether MRI results correlated with subsequent findings, and to determine the effect on clinical management. 3D steady state gradient-echo sequence, fast imaging with steady state precession (FISP), was used. We employed a simplified protocol not requiring bolus timing or subtraction to achieve rapid data acquisition and hence good compliance in this group of frail patients. Following intravenous administration of a bolus of gadolinium, two acquisitions were obtained in order to ensure adequate opacification of all veins. Individual partitions and maximum intensity projections were then analysed to determine whether the veins were patent, stenosed or occluded. RESULTS: The indications for MRI were to assess the patency of central veins for the purpose of cannulation or arteriovenous fistula formation in 17 patients. Out of the 12 patients who proceeded to an intervention, MRI venography successfully predicted an appropriate site in 10 patients. In the remaining seven patients, MRI venography was valuable in confirming or excluding the clinical suspicion of central venous thrombosis and directly influenced the management in five patients. CONCLUSION: 3D gadolinium-enhanced MRI venography is a valuable means of providing a global representation of the central venous system and guiding subsequent central venous cannulation. Oxtoby, J.W. et al. (2001)

  3. Partial Internal Control Recovery on 1-D Klein-Gordon Systems

    Directory of Open Access Journals (Sweden)

    Iwan Pranoto

    2010-03-01

    Full Text Available In this exposition, a technique to recover internal control on a distributed parameter system is reported. The system is described by 1-D Klein-Gordon partial differential equation with a time-varying parameter. We would like to recover the internal control applied to the system if we know some limited information about the output. We use a method called sentinel method to recover the internal control. It involves some construction of a linear functional, and we show that this construction relates closely to the exact controllability problem.

  4. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].

    Science.gov (United States)

    Parra-Bravo, José Rafael; Apolonio-Martínez, Adriana; Estrada-Loza, María de Jesús; Beirana-Palencia, Luisa Gracia; Ramírez-Portillo, César Iván

    2015-01-01

    The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusionductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  5. YouDash3D: exploring stereoscopic 3D gaming for 3D movie theaters

    Science.gov (United States)

    Schild, Jonas; Seele, Sven; Masuch, Maic

    2012-03-01

    Along with the success of the digitally revived stereoscopic cinema, events beyond 3D movies become attractive for movie theater operators, i.e. interactive 3D games. In this paper, we present a case that explores possible challenges and solutions for interactive 3D games to be played by a movie theater audience. We analyze the setting and showcase current issues related to lighting and interaction. Our second focus is to provide gameplay mechanics that make special use of stereoscopy, especially depth-based game design. Based on these results, we present YouDash3D, a game prototype that explores public stereoscopic gameplay in a reduced kiosk setup. It features live 3D HD video stream of a professional stereo camera rig rendered in a real-time game scene. We use the effect to place the stereoscopic effigies of players into the digital game. The game showcases how stereoscopic vision can provide for a novel depth-based game mechanic. Projected trigger zones and distributed clusters of the audience video allow for easy adaptation to larger audiences and 3D movie theater gaming.

  6. Application and Performance of 3D Printing in Nanobiomaterials

    Directory of Open Access Journals (Sweden)

    Wenyong Liu

    2013-01-01

    Full Text Available 3D printing (3DP is becoming a research and development focus in nanobiomaterials as it can quickly and accurately fabricate any desired 3D tissuemodel only if itssize is appropriate. The different material powders (with different dimensional scales and the printing strategies are the most direct factors influencing 3DP quality. With the development of nanotechnologies, 3DP is adopted more frequently for its rapidness in fabrication and precision in geometry. The fabrication in micro/nanoscale may change the performance of biomaterials and devices because it can retain more anisotropy of biomaterials compared with the traditionally rapid prototyping techniques. Thus, the biosafety issue is especially concerned by many researchers and is investigated in performance and safety of biomaterials and devices. This paper investigates the performance of 3DP in fabrication of nanobiomaterials and devices so as to partially explain how 3DP influences the performance and safety of nanobiomaterials.

  7. Successful treatment of dopamine dysregulation syndrome with dopamine D2 partial agonist antipsychotic drug

    Directory of Open Access Journals (Sweden)

    Mizushima Jin

    2012-07-01

    Full Text Available Abstract Dopamine dysregulation syndrome (DDS consists of a series of complications such as compulsive use of dopaminergic medications, aggressive or hypomanic behaviors during excessive use, and withdrawal states characterized by dysphoria and anxiety, caused by long-term dopaminergic treatment in patients with Parkinson’s disease (PD. Although several ways to manage DDS have been suggested, there has been no established treatment that can manage DDS without deterioration of motor symptoms. In this article, we present a case of PD in whom the administration of the dopamine D2 partial agonistic antipsychotic drug aripiprazole improved DDS symptoms such as craving and compulsive behavior without worsening of motor symptoms. Considering the profile of this drug as a partial agonist at D2 receptors, it is possible that it exerts its therapeutic effect on DDS by modulating the dysfunctional dopamine system.

  8. The role and impact of 3D printing technologies in casting

    Directory of Open Access Journals (Sweden)

    Jin-wu Kang

    2017-05-01

    Full Text Available 3D printing is such a magical technology that it extends into almost every sector relating to manufacturing, not to mention casting production. In this paper, the past, present and future of 3D printing in the foundry sector are profoundly reviewed. 3D printing has the potential to supplement or partially replace the casting method. Today, some castings can be directly printed by metal powders, for example, titanium alloys, nickel alloys and steel parts. Meanwhile, 3D printing has found an unique position in other casting aspects as well, such as printing the wax pattern, ceramic shell, sand core, sand mould, etc. Most importantly, 3D printing is not just a manufacturing method, it will also revolutionize the design of products, assemblies and parts, such as castings, patterns, cores, moulds and shells in casting production. The solid structure of castings and moulds will be redesigned in future into truss or spatially open and skeleton structures. This kind of revolution is just sprouting, but it will bring unimaginable impact on manufacturing including casting production. Nobody doubts the potential of 3D printing technologies in manufacturing, but they do have limitations and drawbacks.

  9. Facial expression recognition under partial occlusion based on fusion of global and local features

    Science.gov (United States)

    Wang, Xiaohua; Xia, Chen; Hu, Min; Ren, Fuji

    2018-04-01

    Facial expression recognition under partial occlusion is a challenging research. This paper proposes a novel framework for facial expression recognition under occlusion by fusing the global and local features. In global aspect, first, information entropy are employed to locate the occluded region. Second, principal Component Analysis (PCA) method is adopted to reconstruct the occlusion region of image. After that, a replace strategy is applied to reconstruct image by replacing the occluded region with the corresponding region of the best matched image in training set, Pyramid Weber Local Descriptor (PWLD) feature is then extracted. At last, the outputs of SVM are fitted to the probabilities of the target class by using sigmoid function. For the local aspect, an overlapping block-based method is adopted to extract WLD features, and each block is weighted adaptively by information entropy, Chi-square distance and similar block summation methods are then applied to obtain the probabilities which emotion belongs to. Finally, fusion at the decision level is employed for the data fusion of the global and local features based on Dempster-Shafer theory of evidence. Experimental results on the Cohn-Kanade and JAFFE databases demonstrate the effectiveness and fault tolerance of this method.

  10. Near-liquidus forging, partial remelting and thixoforging of an AZ91D + Y magnesium alloy

    International Nuclear Information System (INIS)

    Zhao Zude; Chen Qiang; Hu Chuankai; Huang Shuhai; Wang Yuanqing

    2009-01-01

    A new route, near-liquidus forging plus partial remelting, has been developed for obtaining globular microstructures. Firstly, a material is formed by near-liquidus forging for obtaining a fine dendritic microstructure. Globular microstructure can be produced by reheating the material into the semi-solid temperature range for a period of time. In this paper, an AZ91D alloy with the addition of yttrium was prepared by near-liquidus forging. Microstructure evolution during partial remelting was studied at temperatures and for times. Tensile mechanical properties of thixoforged components were also determined. It is shown that the fine dendritic structure firstly evolves into a blocky structure during partial remelting. With prolonged holding time, the blocky structure disintegrates into polygonal solid particles. Prolonging time and increasing temperature promote a faster spheroidization. Good mechanical properties are obtained for the thixoforged AZ91D alloy with the addition of yttrium prepared by near-liquidus forging, with a yield strength of 160.9 MPa and a ultimate tensile strength of 301.7 MPa and a elongation to fracture of 9.734%.

  11. Comparison of axial lengths in occludable angle and angle-closure glaucoma-The Bhaktapur Glaucoma Study

    NARCIS (Netherlands)

    Thapa, S.S.; Paudyal, I.; Khanal, S.; Paudel, N.; van Rens, G.H.M.B.

    2011-01-01

    Purpose. To compare the anterior chamber depth (ACD) and axial length of eyes in a population-based sample among normal, occludable angle, and primary angle-closure glaucoma (PACG) groups. Methods. Totally, 3979 subjects from a population-based glaucoma prevalence study underwent complete ocular

  12. Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS.

    Science.gov (United States)

    Morville, Patrice; Akhavi, Ahmad

    2017-10-01

    The advent of Amplatzer Duct Occluder II additional Size (ADOIIAS) provided the potential to close hemodynamic significant patent ductus arteriosus (HSPDA) and to analyze the feasibility, safety and efficacy of the device. Treatment of a patent ductus arteriosus (PDA) in very premature neonates is still a dilemma for the neonatalogist who has to consider its significance and has to choose among different treatment options. Because surgical ligation and medical therapy both have their drawbacks, interventional catheterization might provide an alternative means of closing HSPDA. Between September 2013 and June 2015, 32 premature infants with complications related to HSPDA defined by ultrasound (US) underwent transcatheter closure. The procedure was performed in the catheterization laboratory by venous cannulation without angiography. The position of the occluder was directed by X-ray and US. In particular we looked at procedural details, device size selection, complications, and short and mid-term outcomes. Thirty two premature infants, all of whom had clinical complications related to HSPDA, born at gestational ages ranging between 23.6 and 36 weeks (mean ± standard deviation 28 ± 3 weeks) underwent attempted transcatheter PDA closure using the ADOIIAS. Their mean age and weight at the time of procedure was 25 days (range 8-70 days) and 1373 g (range 680-2480 g), respectively. Ten infants weighed ≤1,000g. All ducts were tubular. The mean PDA and device waist diameters were 3.2 ± 0.6mm (range 2.2-4) and 4.4 ± 0.6 mm, respectively, and the mean PDA and device lengths 5.2 ± 2.0 mm (range 2-10) and 3.4 ± 1.3 mm. Median fluoroscopy and procedural times were 11 min (range 3-24) and 28 min (range 10-90), respectively. Complete closure was achieved in all but one patient. There was no device migration. A left pulmonary artery (LPA) obstruction developed in one patient. Five infants died. Four deaths were related to complications of

  13. 3D-mallien muokkaus 3D-tulostamista varten CAD-ohjelmilla

    OpenAIRE

    Lehtimäki, Jarmo

    2013-01-01

    Insinöörityössäni käsitellään 3D-mallien tulostamista ja erityisesti 3D-mallien mallintamista niin, että kappaleiden valmistaminen 3D-tulostimella onnistuisi mahdollisimman hyvin. Työ tehtiin Prohoc Oy:lle, joka sijaitsee Vaasassa. 3D-tulostuspalveluun tuli jatkuvasti 3D-malleja, joiden tulostuksessa oli ongelmia. Työssäni tutkin näiden ongelmien syntyä ja tein ohjeita eri 3D-mallinnusohjelmille, joiden tarkoituksena on auttaa tekemään helpommin tulostettavia 3D-malleja. Työhön kuului myös et...

  14. Determination of occluded helium and oxygen in irradiated borosilicate glass samples

    International Nuclear Information System (INIS)

    Ramanjaneyulu, P.S.; Kulkarni, A.S.; Shrivastava, K.C.; Yadav, C.S.; Saxena, M.K.; Tomar, B.S.; Ramakumar, K.L.; Shah, J.G.

    2015-01-01

    Occluded gases in irradiated borosilicate glass were determined at 573, 873 and 1273 K for understanding the radiation damage in glass matrix. Hot vacuum extraction coupled with a quadrupole mass spectrometer technique was employed for the measurements. Relative sensitivity factors of various gases in QMS system were also determined and used for gas composition calculations. At 573 K only helium was found to get released whereas at 873 and 1273 K both helium and oxygen were released with major fraction of oxygen. (author)

  15. 3D imaging, 3D printing and 3D virtual planning in endodontics.

    Science.gov (United States)

    Shah, Pratik; Chong, B S

    2018-03-01

    The adoption and adaptation of recent advances in digital technology, such as three-dimensional (3D) printed objects and haptic simulators, in dentistry have influenced teaching and/or management of cases involving implant, craniofacial, maxillofacial, orthognathic and periodontal treatments. 3D printed models and guides may help operators plan and tackle complicated non-surgical and surgical endodontic treatment and may aid skill acquisition. Haptic simulators may assist in the development of competency in endodontic procedures through the acquisition of psycho-motor skills. This review explores and discusses the potential applications of 3D printed models and guides, and haptic simulators in the teaching and management of endodontic procedures. An understanding of the pertinent technology related to the production of 3D printed objects and the operation of haptic simulators are also presented.

  16. Efficacy of electrocoagulation in sealing the cystic artery and cystic duct occluded with only one absorbable clip during laparoscopic cholecystectomy.

    Science.gov (United States)

    Yang, Chang-Ping; Cao, Jin-Lin; Yang, Ren-Rong; Guo, Hong-Rong; Li, Zhao-Hui; Guo, Hai-Ying; Shao, Yin-Can; Liu, Gui-Bao

    2014-02-01

    Even though laparoscopic cholecystectomy (LC) emerged over 20 years ago, controversies persist with regard to the best method to ligate the cystic duct and artery. We proposed to assess the effectiveness and safety of electrocoagulation to seal the cystic artery and cystic duct after their occlusion with only one absorbable clip. We retrospectively compared the clinical data for 635 patients undergoing LC using electrocoagulation to seal the cystic artery and cystic duct that were occluded with only one absorbable clip (Group 1) and 728 patients undergoing LC using titanium clips (Group 2). In parallel, 30 rabbits randomized into six groups underwent cholecystectomy. After cystic duct ligation with absorbable or titanium clips, the animals were sacrificed 1, 3, or 6 months later, and intraabdominal adhesions were assessed after celiotomy. The mean operative time was significantly shorter (41.6 versus 58.9 minutes, PElectrocoagulation of the cystic artery and cystic duct that were occluded with only one absorbable clip is safe and effective during LC. This approach is associated with shortened operative times and reduced leakage, compared with the standard method using metal clips.

  17. A 3d-3d appetizer

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Du; Ye, Ke [Walter Burke Institute for Theoretical Physics, California Institute of Technology, Pasadena, CA, 91125 (United States)

    2016-11-02

    We test the 3d-3d correspondence for theories that are labeled by Lens spaces. We find a full agreement between the index of the 3d N=2 “Lens space theory” T[L(p,1)] and the partition function of complex Chern-Simons theory on L(p,1). In particular, for p=1, we show how the familiar S{sup 3} partition function of Chern-Simons theory arises from the index of a free theory. For large p, we find that the index of T[L(p,1)] becomes a constant independent of p. In addition, we study T[L(p,1)] on the squashed three-sphere S{sub b}{sup 3}. This enables us to see clearly, at the level of partition function, to what extent G{sub ℂ} complex Chern-Simons theory can be thought of as two copies of Chern-Simons theory with compact gauge group G.

  18. Conservation Laws for Partially Conservative Variable Mass Systems via d'Alembert's Principle

    Institute of Scientific and Technical Information of China (English)

    AFTAB Ahmed; NASEER Ahmed; QUDRAT Khan

    2008-01-01

    Conservation laws for partially conservative variable mass dynamical systems under symmetric infinitesimal transformations are determined. A generalization of Lagrange-d'Alembert's principle for a variable mass system in terms of asynchronous virtual variation is presented. The generalized Killing equations are obtained such that their solution yields the transformations and the associated conservation laws. An example illustrative of the theory is furnished at the end as well.

  19. Sympathetic responses during saline infusion into the veins of an occluded limb.

    Science.gov (United States)

    Cui, Jian; McQuillan, Patrick; Moradkhan, Raman; Pagana, Charles; Sinoway, Lawrence I

    2009-07-15

    Animal studies have shown that the increased intravenous pressure stimulates the group III and IV muscle afferent fibres, and in turn induce cardiovascular responses. However, this pathway of autonomic regulation has not been examined in humans. The aim of this study was to examine the hypothesis that infusion of saline into the venous circulation of an arterially occluded vascular bed evokes sympathetic activation in healthy individuals. Blood pressure, heart rate, and muscle sympathetic nerve activity (MSNA) responses were assessed in 19 young healthy subjects during local infusion of 40 ml saline into a forearm vein in the circulatory arrested condition. From baseline (11.8 +/- 1.2 bursts min(-1)), MSNA increased significantly during the saline infusion (22.5 +/- 2.6 bursts min(-1), P Blood pressure also increased significantly during the saline infusion. Three control trials were performed during separate visits. The results from the control trial show that the observed MSNA and blood pressure responses were not due to muscle ischaemia. The present data show that saline infusion into the venous circulation of an arterially occluded vascular bed induces sympathetic activation and an increase in blood pressure. We speculate that the infusion under such conditions stimulates the afferent endings near the vessels, and evokes the sympathetic activation.

  20. Amplatzer angled duct occluder for closure of patent ductus arteriosus larger than the aorta in an infant.

    Science.gov (United States)

    Vijayalakshmi, I B; Chitra, N; Rajasri, R; Prabhudeva, A N

    2005-01-01

    Transcatheter closure of patent ductus arteriosus (PDA) by Amplatzer duct occluder is the treatment of choice. However, closure of very large ducts in infants with low weight is a challenge for the interventionalist because a large device may obstruct the aorta or left pulmonary artery. Difficulty is also encountered in advancing the device around the curve of the right ventricular outflow tract toward the pulmonary artery; this curve is tight, more or less at a right angle in infants, leading to kinking of the sheath, which increases fluoroscopic time. This is the first reported case of a very large PDA (8.7 mm), larger than the aorta (8.2 mm), successfully closed by an Amplatzer angled duct occluder in an infant weighing 5 kg.

  1. Asymptomatic Partial Splenic Infarction In Laparoscopic Floppy Nissen Fundoplication And Brief Literature Review

    Science.gov (United States)

    Odabasi, Mehmet; Abuoglu, Haci Hasan; Arslan, Cem; Gunay, Emre; Yildiz, Mehmet Kamil; Eris, Cengiz; Ozkan, Erkan; Aktekin, Ali; Muftuoglu, Tolga

    2014-01-01

    Short gastric vessels are divided during the laparoscopic Nissen fundoplication resulting in splenic infarct in some cases. We report a case of laparoscopic floppy Nissen fundoplication with splenic infarct that was recognized during the procedure and provide a brief literature review. The patient underwent a laparoscopic floppy Nissen fundoplication. We observed a partial infarction of the spleen. She reported no pain. A follow-up computed tomography scan showed an infarct, and a 3-month abdominal ultrasound showed complete resolution. Peripheral splenic arterial branches have very little collateral circulation. When these vessels are occluded or injured, an area of infarction will occur immediately. Management strategies included a trial of conservative management and splenectomy for persistent symptoms or complications resulting from splenic infarct. In conclusion, we believe that the real incidence is probably much higher because many cases of SI may have gone undiagnosed during or following an operation, because some patients are asymptomatic. We propose to check spleen carefully for the possibility of splenic infarct. PMID:24833155

  2. 3-D Ultrasound Vascularity Assessment for Breast Cancer Diagnosis

    Science.gov (United States)

    2000-09-01

    Boehm, T., Shing, Y ., Fdkai, N., Vasios, G., Lane, 29. Parke, A., Bhattacherjee, P., Palmer, R. M., and Lazarus , N. R. W. S., Flynn, E., Birkhead, J...P. L. Utility of 3D ultrasound in the R. A., Moses, M., Lane, W. S., Cao, Y ., Sage, E. H., and Folkman , J. discrimination and detection of breast...References/Appendices 7), (Abstracts y (mm) (min/set) 6,7,9,10,18); 5) expanding the field of view 5x5x5 subvols. 0.17 5.3 by combining several partially

  3. Quasi 3D dosimetry (EPID, conventional 2D/3D detector matrices)

    International Nuclear Information System (INIS)

    Bäck, A

    2015-01-01

    Patient specific pretreatment measurement for IMRT and VMAT QA should preferably give information with a high resolution in 3D. The ability to distinguish complex treatment plans, i.e. treatment plans with a difference between measured and calculated dose distributions that exceeds a specified tolerance, puts high demands on the dosimetry system used for the pretreatment measurements and the results of the measurement evaluation needs a clinical interpretation. There are a number of commercial dosimetry systems designed for pretreatment IMRT QA measurements. 2D arrays such as MapCHECK ® (Sun Nuclear), MatriXX Evolution (IBA Dosimetry) and OCTAVIOUS ® 1500 (PTW), 3D phantoms such as OCTAVIUS ® 4D (PTW), ArcCHECK ® (Sun Nuclear) and Delta 4 (ScandiDos) and software for EPID dosimetry and 3D reconstruction of the dose in the patient geometry such as EPIDose TM (Sun Nuclear) and Dosimetry Check TM (Math Resolutions) are available. None of those dosimetry systems can measure the 3D dose distribution with a high resolution (full 3D dose distribution). Those systems can be called quasi 3D dosimetry systems. To be able to estimate the delivered dose in full 3D the user is dependent on a calculation algorithm in the software of the dosimetry system. All the vendors of the dosimetry systems mentioned above provide calculation algorithms to reconstruct a full 3D dose in the patient geometry. This enables analyzes of the difference between measured and calculated dose distributions in DVHs of the structures of clinical interest which facilitates the clinical interpretation and is a promising tool to be used for pretreatment IMRT QA measurements. However, independent validation studies on the accuracy of those algorithms are scarce. Pretreatment IMRT QA using the quasi 3D dosimetry systems mentioned above rely on both measurement uncertainty and accuracy of calculation algorithms. In this article, these quasi 3D dosimetry systems and their use in patient specific

  4. Global Regularity and Time Decay for the 2D Magnetohydrodynamic Equations with Fractional Dissipation and Partial Magnetic Diffusion

    Science.gov (United States)

    Dong, Bo-Qing; Jia, Yan; Li, Jingna; Wu, Jiahong

    2018-05-01

    This paper focuses on a system of the 2D magnetohydrodynamic (MHD) equations with the kinematic dissipation given by the fractional operator (-Δ )^α and the magnetic diffusion by partial Laplacian. We are able to show that this system with any α >0 always possesses a unique global smooth solution when the initial data is sufficiently smooth. In addition, we make a detailed study on the large-time behavior of these smooth solutions and obtain optimal large-time decay rates. Since the magnetic diffusion is only partial here, some classical tools such as the maximal regularity property for the 2D heat operator can no longer be applied. A key observation on the structure of the MHD equations allows us to get around the difficulties due to the lack of full Laplacian magnetic diffusion. The results presented here are the sharpest on the global regularity problem for the 2D MHD equations with only partial magnetic diffusion.

  5. Three-dimensional (3D) MRI of the knee. IRM tridimensionnelle du genou

    Energy Technology Data Exchange (ETDEWEB)

    Shahabpour, M.; Spruyt, D.; Leroux, G.B.; Osteaux, M. (Vrije Univ., Brussels (Belgium))

    1993-01-01

    Three-dimensional gradient echo T2-weighted sequences have a number of advantages over spin echo T2-weighted sequences (or even 2D gradient echo T2-weighted sequences) for assessment of the knee. They allow a multidimensional analysis based on a single acquisition sequence usually obtained in the sagittal plane. Image reconstructions can be performed secondarily in the coronal, axial and oblique planes, particularly along the specific path of the anterior cruciate ligament. By providing ultrathin serial sections, decreasing the partial volume effect, small lesions, such as cartilaginous fissures or flaps and radial meniscal lesions can be detected in the axial plane, for example. This advantage, combined with the marked sensitivity of gradient echo sequences to alterations in the tissue water content, allows the detection of partial tendon ruptures. The reduction of the partial volume effect and chemical shift artefact probably participate in the capacity of these sequences to visualize the two surfaces of the cartilage of the femorotibial joint. Flow artefacts are less of a problem than with 2D imaging, which eliminates the need for techniques such as saturation of the vascular signal or cardiac gating. A disadvantage of these gradient echo sequences (3D or 2D) is their sensitivity to the presence of metallic material, limiting their application in operated knees.

  6. Buspirone Counteracts MK-801-Induced Schizophrenia-Like Phenotypes through Dopamine D3 Receptor Blockade

    Science.gov (United States)

    Torrisi, Sebastiano Alfio; Salomone, Salvatore; Geraci, Federica; Caraci, Filippo; Bucolo, Claudio; Drago, Filippo; Leggio, Gian Marco

    2017-01-01

    Background: Several efforts have been made to develop effective antipsychotic drugs. Currently, available antipsychotics are effective on positive symptoms, less on negative symptoms, but not on cognitive impairment, a clinically relevant dimension of schizophrenia. Drug repurposing offers great advantages over the long-lasting, risky and expensive, de novo drug discovery strategy. To our knowledge, the possible antipsychotic properties of buspirone, an azapirone anxiolytic drug marketed in 1986 as serotonin 5-HT1A receptor (5-HT1AR) partial agonist, have not been extensively investigated despite its intriguing pharmacodynamic profile, which includes dopamine D3 (D3R) and D4 receptor (D4R) antagonist activity. Multiple lines of evidence point to D3R as a valid therapeutic target for the treatment of several neuropsychiatric disorders including schizophrenia. In the present study, we tested the hypothesis that buspirone, behaving as dopamine D3R antagonist, may have antipsychotic-like activity. Materials and Methods: Effects of acute administration of buspirone was assessed on a wide-range of schizophrenia-relevant abnormalities induced by a single administration of the non-competitive NMDAR antagonist MK-801, in both wild-type mice (WT) and D3R-null mutant mice (D3R-/-). Results: Buspirone (3 mg⋅kg-1, i.p.) was devoid of cataleptogenic activity in itself, but resulted effective in counteracting disruption of prepulse inhibition (PPI), hyperlocomotion and deficit of temporal order recognition memory (TOR) induced by MK-801 (0.1 mg⋅kg-1, i.p.) in WT mice. Conversely, in D3R-/- mice, buspirone was ineffective in preventing MK-801-induced TOR deficit and it was only partially effective in blocking MK-801-stimulated hyperlocomotion. Conclusion: Taken together, these results indicate, for the first time, that buspirone, might be a potential therapeutic medication for the treatment of schizophrenia. In particular, buspirone, through its D3R antagonist activity, may be

  7. Characterization and partial purification of phospholipase D from human placenta

    DEFF Research Database (Denmark)

    Vinggaard, Anne Marie; Hansen, Harald S.

    1995-01-01

    We report the existence in the human placenta of a phosphatidylcholine- hydrolyzing phospholipase D (PLD) activity, which has been characterized and partially purified. Triton X-100 effectively solubilized PLD from the particulate fraction of human placenta in a dose-dependent manner. However......, Triton X-100 caused decreasing enzyme activities. Maximum transphosphatidylation was obtained with 2% ethanol. The enzyme was found to have a pH optimum of 7.0-7.5 and an apparent K(m) of 33 mol% (or 0.8 mM). Ca and Mg was not required for the enzyme activity. Addition of phosphatidyl-4,5-bisphosphate...

  8. Lifetime differences, direct CP violation, and partial widths in D0 meson decays to K+K- and π+π-

    International Nuclear Information System (INIS)

    Csorna, S.E.; Danko, I.; McLean, K.W.

    2002-01-01

    We describe several measurements using the decays D 0 →K + K - and π + π - . We find the ratio of partial widths, Γ(D 0 →K + K - )/Γ(D 0 →π + π - ), to be 2.96±0.16±0.15, where the first error is statistical and the second is systematic. We observe no evidence for direct CP violation, obtaining A CP (KK)=(0.0±2.2±0.8)% and A CP (ππ)=(1.9±3.2±0.8)%. In the limit of no CP violation we measure the mixing parameter y CP =-0.012±0.025±0.014 by measuring the lifetime difference between D 0 →K + K - or π + π - and the CP neutral state, D 0 →K - π + . We see no evidence for mixing

  9. 3D MR cisternography to identify distal dural rings. Comparison of 3D-CISS and 3D-SPACE sequences

    International Nuclear Information System (INIS)

    Watanabe, Yoshiyuki; Makidono, Akari; Nakamura, Miho; Saida, Yukihisa

    2011-01-01

    The distal dural ring (DDR) is an anatomical landmark used to distinguish intra- and extradural aneurysms. We investigated identification of the DDR using 2 three-dimensional (3D) magnetic resonance (MR) cisternography sequences-3D constructive interference in steady state (CISS) and 3D sampling perfection with application optimized contrasts using different flip angle evolutions (SPACE)-at 3.0 tesla. Ten healthy adult volunteers underwent imaging with 3D-CISS, 3D-SPACE, and time-of-flight (TOF) MR angiography (TOF-MRA) sequences at 3.0T. We analyzed DDR identification and internal carotid artery (ICA) signal intensity and classified the shape of the carotid cave. We identified the DDR using both 3D-SPACE and 3D-CISS, with no significant difference between the sequences. Visualization of the outline of the ICA in the cavernous sinus (CS) was significantly clearer with 3D-SPACE than 3D-CISS. In the CS and petrous portions, signal intensity was lower with 3D-SPACE, and the flow void was poor with 3D-CISS in some subjects. We identified the DDR with both 3D-SPACE and 3D-CISS, but the superior contrast of the ICA in the CS using 3D-SPACE suggests the superiority of this sequence for evaluating the DDR. (author)

  10. UT inspection of nozzles by 3D raytracing

    International Nuclear Information System (INIS)

    Isenberg, J.; Koshy, M.; Carcione, L.

    2004-01-01

    This paper documents how we have adapted 3D geometric modeling and ray tracing to support design and verification of wedges and preparation of coverage maps for ultrasonic inspection of BWR nozzles. This software is capable of addressing a broad range of modeling issues, including ray tracing in completely general 3D objects comprised of blocky, transversely isotropic material. However, to capitalize on the full range of capability usually requires an investment of time on the part of users. To make 3D modeling accessible to users who have time-urgent requirements or who do not need to utilize the full capabilities of the software, we have developed specialized applications in which restrictions on generality are accepted in exchange for easy access to model building, wedge design and coverage maps for detecting flaws in the bore and inner blend regions of nozzles. This is done by providing partially-completed, parametrized models which give the user latitude to generate general models within a fixed framework. We also provide a graphical user interface which anticipates certain tasks that a user will wish to undertake; other tasks may readily be added. (author)

  11. Near-threshold photoionization of the Xe 3d spin-orbit doublet: Relativistic, relaxation, and intershell interaction effects

    International Nuclear Information System (INIS)

    Radojevic, V.; Davidovic, D.M.; Amusia, M.Ya.

    2003-01-01

    Results of calculations of the near-threshold photoionization of the xenon 3d spin-orbit doublet are reported. Our theoretical analysis is undertaken in order to interpret and enlighten the very detailed measurements of this process [A. Kivimaeki et al., Phys. Rev. A 63, 012716 (2001)], which revealed a previously unobserved interesting feature--an additional broad maximum--in the partial xenon 3d 5/2 cross section. This double maximum was not produced by earlier calculations, except in the recent study by Amusia et al. [Phys. Rev. Lett. 88, 093002 (2002)], which, in contrast to the present one, is not ab initio and relativistic in character. The partial photoionization cross sections of 3d 5/2 and 3d 3/2 subshells, photoelectron anisotropy parameters, and spin-polarization parameters that were so far not studied either experimentally or theoretically are calculated. Many-electron correlations, relativistic effects, and relaxation effects of the ionic core in the ionization process are taken into account by using the relativistic random-phase approximation, modified to include the relaxation of the considered subshell

  12. 3D video

    CERN Document Server

    Lucas, Laurent; Loscos, Céline

    2013-01-01

    While 3D vision has existed for many years, the use of 3D cameras and video-based modeling by the film industry has induced an explosion of interest for 3D acquisition technology, 3D content and 3D displays. As such, 3D video has become one of the new technology trends of this century.The chapters in this book cover a large spectrum of areas connected to 3D video, which are presented both theoretically and technologically, while taking into account both physiological and perceptual aspects. Stepping away from traditional 3D vision, the authors, all currently involved in these areas, provide th

  13. 3D composite image, 3D MRI, 3D SPECT, hydrocephalus

    International Nuclear Information System (INIS)

    Mito, T.; Shibata, I.; Sugo, N.; Takano, M.; Takahashi, H.

    2002-01-01

    The three-dimensional (3D)SPECT imaging technique we have studied and published for the past several years is an analytical tool that permits visual expression of the cerebral circulation profile in various cerebral diseases. The greatest drawback of SPECT is that the limitation on precision of spacial resolution makes intracranial localization impossible. In 3D SPECT imaging, intracranial volume and morphology may vary with the threshold established. To solve this problem, we have produced complimentarily combined SPECT and helical-CT 3D images by means of general-purpose visualization software for intracranial localization. In hydrocephalus, however, the key subject to be studied is the profile of cerebral circulation around the ventricles of the brain. This suggests that, for displaying the cerebral ventricles in three dimensions, CT is a difficult technique whereas MRI is more useful. For this reason, we attempted to establish the profile of cerebral circulation around the cerebral ventricles by the production of combined 3D images of SPECT and MRI. In patients who had shunt surgery for hydrocephalus, a difference between pre- and postoperative cerebral circulation profiles was assessed by a voxel distribution curve, 3D SPECT images, and combined 3D SPECT and MRI images. As the shunt system in this study, an Orbis-Sigma valve of the automatic cerebrospinal fluid volume adjustment type was used in place of the variable pressure type Medos valve currently in use, because this device requires frequent changes in pressure and a change in pressure may be detected after MRI procedure. The SPECT apparatus used was PRISM3000 of the three-detector type, and 123I-IMP was used as the radionuclide in a dose of 222 MBq. MRI data were collected with an MAGNEXa+2 with a magnetic flux density of 0.5 tesla under the following conditions: field echo; TR 50 msec; TE, 10 msec; flip, 30ueK; 1 NEX; FOV, 23 cm; 1-mm slices; and gapless. 3D images are produced on the workstation TITAN

  14. 3D Printing and 3D Bioprinting in Pediatrics.

    Science.gov (United States)

    Vijayavenkataraman, Sanjairaj; Fuh, Jerry Y H; Lu, Wen Feng

    2017-07-13

    Additive manufacturing, commonly referred to as 3D printing, is a technology that builds three-dimensional structures and components layer by layer. Bioprinting is the use of 3D printing technology to fabricate tissue constructs for regenerative medicine from cell-laden bio-inks. 3D printing and bioprinting have huge potential in revolutionizing the field of tissue engineering and regenerative medicine. This paper reviews the application of 3D printing and bioprinting in the field of pediatrics.

  15. 3D Printing and 3D Bioprinting in Pediatrics

    OpenAIRE

    Vijayavenkataraman, Sanjairaj; Fuh, Jerry Y H; Lu, Wen Feng

    2017-01-01

    Additive manufacturing, commonly referred to as 3D printing, is a technology that builds three-dimensional structures and components layer by layer. Bioprinting is the use of 3D printing technology to fabricate tissue constructs for regenerative medicine from cell-laden bio-inks. 3D printing and bioprinting have huge potential in revolutionizing the field of tissue engineering and regenerative medicine. This paper reviews the application of 3D printing and bioprinting in the field of pediatrics.

  16. A microfluidic device for 2D to 3D and 3D to 3D cell navigation

    International Nuclear Information System (INIS)

    Shamloo, Amir; Amirifar, Leyla

    2016-01-01

    Microfluidic devices have received wide attention and shown great potential in the field of tissue engineering and regenerative medicine. Investigating cell response to various stimulations is much more accurate and comprehensive with the aid of microfluidic devices. In this study, we introduced a microfluidic device by which the matrix density as a mechanical property and the concentration profile of a biochemical factor as a chemical property could be altered. Our microfluidic device has a cell tank and a cell culture chamber to mimic both 2D to 3D and 3D to 3D migration of three types of cells. Fluid shear stress is negligible on the cells and a stable concentration gradient can be obtained by diffusion. The device was designed by a numerical simulation so that the uniformity of the concentration gradients throughout the cell culture chamber was obtained. Adult neural cells were cultured within this device and they showed different branching and axonal navigation phenotypes within varying nerve growth factor (NGF) concentration profiles. Neural stem cells were also cultured within varying collagen matrix densities while exposed to NGF concentrations and they experienced 3D to 3D collective migration. By generating vascular endothelial growth factor concentration gradients, adult human dermal microvascular endothelial cells also migrated in a 2D to 3D manner and formed a stable lumen within a specific collagen matrix density. It was observed that a minimum absolute concentration and concentration gradient were required to stimulate migration of all types of the cells. This device has the advantage of changing multiple parameters simultaneously and is expected to have wide applicability in cell studies. (paper)

  17. Higher Order Lagrange Finite Elements In M3D

    International Nuclear Information System (INIS)

    Chen, J.; Strauss, H.R.; Jardin, S.C.; Park, W.; Sugiyama, L.E.; Fu, G.; Breslau, J.

    2004-01-01

    The M3D code has been using linear finite elements to represent multilevel MHD on 2-D poloidal planes. Triangular higher order elements, up to third order, are constructed here in order to provide M3D the capability to solve highly anisotropic transport problems. It is found that higher order elements are essential to resolve the thin transition layer characteristic of the anisotropic transport equation, particularly when the strong anisotropic direction is not aligned with one of the Cartesian coordinates. The transition layer is measured by the profile width, which is zero for infinite anisotropy. It is shown that only higher order schemes have the ability to make this layer converge towards zero when the anisotropy gets stronger and stronger. Two cases are considered. One has the strong transport direction partially aligned with one of the element edges, the other doesn't have any alignment. Both cases have the strong transport direction misaligned with the grid line by some angles

  18. 3D game environments create professional 3D game worlds

    CERN Document Server

    Ahearn, Luke

    2008-01-01

    The ultimate resource to help you create triple-A quality art for a variety of game worlds; 3D Game Environments offers detailed tutorials on creating 3D models, applying 2D art to 3D models, and clear concise advice on issues of efficiency and optimization for a 3D game engine. Using Photoshop and 3ds Max as his primary tools, Luke Ahearn explains how to create realistic textures from photo source and uses a variety of techniques to portray dynamic and believable game worlds.From a modern city to a steamy jungle, learn about the planning and technological considerations for 3D modelin

  19. Plasma and milk concentrations of vitamin D3 and 25-hydroxy vitamin D3 following intravenous injection of vitamin D3 or 25-hydroxy vitamin D3.

    OpenAIRE

    Hidiroglou, M; Knipfel, J E

    1984-01-01

    Plasma levels of vitamin D3 or 25-hydroxyvitamin D3 in ewes after administration of a single massive intravenous dose of vitamin D3 (2 X 10(6) IU) or 25-hydroxy vitamin D3 (5 mg) were determined at zero, one, two, three, five, ten and 20 days postinjection. In six ewes injected with vitamin D3 conversion of vitamin D3 to 25-hydroxy vitamin D3 resulted in a six-fold increase in the plasma 25-hydroxy vitamin D3 level within one day. Elevated levels were maintained until day 10 but by day 20 a s...

  20. Patient Education for Endoscopic Sinus Surgery: Preliminary Experience Using 3D-Printed Clinical Imaging Data.

    Science.gov (United States)

    Sander, Ian M; Liepert, Taimi T; Doney, Evan L; Leevy, W Matthew; Liepert, Douglas R

    2017-04-07

    Within the Ear, Nose, and Throat (ENT) medical space, a relatively small fraction of patients follow through with elective surgeries to fix ailments such as a deviated septum or occluded sinus passage. Patient understanding of their diagnosis and treatment plan is integral to compliance, which ultimately yields improved medical outcomes and better quality of life. Here we report the usage of advanced, polyjet 3D printing methods to develop a multimaterial replica of human nasal sinus anatomy, derived from clinical X-ray computed tomography (CT) data, to be used as an educational aid during physician consultation. The final patient education model was developed over several iterations to optimize material properties, anatomical accuracy and overall display. A two-arm, single-center, randomized, prospective study was then performed in which 50 ENT surgical candidates (and an associated control group, n = 50) were given an explanation of their anatomy, disease state, and treatment options using the education model as an aid. Statistically significant improvements in patient ratings of their physician's explanation of their treatment options ( p = 0.020), self-rated anatomical understanding ( p = 0.043), self-rated understanding of disease state ( p = 0.016), and effectiveness of the visualization ( p = 0.007) were noted from the population that viewed the 3D education model, indicating it is an effective tool which ENT surgeons may use to educate and interact with patients.

  1. Calmodulin promotes matrix metalloproteinase 9 production and cell migration by inhibiting the ubiquitination and degradation of TBC1D3 oncoprotein in human breast cancer cells.

    Science.gov (United States)

    Zhao, Huzi; Zhang, Lina; Zhang, Yongchen; Zhao, Lei; Wan, Qing; Wang, Bei; Bu, Xiaodong; Wan, Meiling; Shen, Chuanlu

    2017-05-30

    The hominoid oncoprotein TBC1D3 enhances growth factor (GF) signaling and GF signaling, conversely, induces the ubiquitination and subsequent degradation of TBC1D3. However, little is known regarding the regulation of this degradation, and the role of TBC1D3 in the progression of tumors has also not been defined. In the present study, we demonstrated that calmodulin (CaM), a ubiquitous cellular calcium sensor, specifically interacted with TBC1D3 in a Ca2+-dependent manner and inhibited GF signaling-induced ubiquitination and degradation of the oncoprotein in both cytoplasm and nucleus of human breast cancer cells. The CaM-interacting site of TBC1D3 was mapped to amino acids 157~171, which comprises two 1-14 hydrophobic motifs and one lysine residue (K166). Deletion of these motifs was shown to abolish interaction between TBC1D3 and CaM. Surprisingly, this deletion mutation caused inability of GF signaling to induce the ubiquitination and subsequent degradation of TBC1D3. In agreement with this, we identified lysine residue 166 within the CaM-interacting motifs of TBC1D3 as the actual site for the GF signaling-induced ubiquitination using mutational analysis. Point mutation of this lysine residue exhibited the same effect on TBC1D3 as the deletion mutant, suggesting that CaM inhibits GF signaling-induced degradation of TBC1D3 by occluding its ubiquitination at K166. Notably, we found that TBC1D3 promoted the expression and activation of MMP-9 and the migration of MCF-7 cells. Furthermore, interaction with CaM considerably enhanced such effect of TBC1D3. Taken together, our work reveals a novel model by which CaM promotes cell migration through inhibiting the ubiquitination and degradation of TBC1D3.

  2. 3-D Whole-Core Transport Calculation with 3D/2D Rotational Plane Slicing Method

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Han Jong; Cho, Nam Zin [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-10-15

    Use of the method of characteristics (MOC) is very popular due to its capability of heterogeneous geometry treatment and widely used for 2-D core calculation, but direct extension of MOC to 3-D core is not so attractive due to huge calculational cost. 2-D/1-D fusion method was very successful for 3-D calculation of current generation reactor types (highly heterogeneous in radial direction but piece-wise homogeneous in axial direction). In this paper, 2-D MOC concept is extended to 3-D core calculation with little modification of an existing 2-D MOC code. The key idea is to suppose 3-D geometry as a set of many 2-D planes like a phone-directory book. Dividing 3-D structure into a large number of 2-D planes and solving each plane with a simple 2-D SN transport method would give the solution of a 3-D structure. This method was developed independently at KAIST but it is found that this concept is similar with that of 'plane tracing' in the MCCG-3D code. The method developed was tested on the 3-D C5G7 OECD/NEA benchmark problem and compared with the 2-D/1-D fusion method. Results show that the proposed method is worth investigating further. A new approach to 3-D whole-core transport calculation is described and tested. By slicing 3-D structure along characteristic planes and solving each 2-D plane problem, we can get 3-D solution. The numerical test results indicate that the new method is comparable with the 2D/1D fusion method and outperforms other existing methods. But more fair comparison should be done in similar discretization level.

  3. 3D-printed soft-tissue physical models of renal malignancies for individualized surgical simulation: a feasibility study.

    Science.gov (United States)

    Maddox, Michael M; Feibus, Allison; Liu, James; Wang, Julie; Thomas, Raju; Silberstein, Jonathan L

    2018-03-01

    To construct patient-specific physical three-dimensional (3D) models of renal units with materials that approximates the properties of renal tissue to allow pre-operative and robotic training surgical simulation, 3D physical kidney models were created (3DSystems, Rock Hill, SC) using computerized tomography to segment structures of interest (parenchyma, vasculature, collection system, and tumor). Images were converted to a 3D surface mesh file for fabrication using a multi-jet 3D printer. A novel construction technique was employed to approximate normal renal tissue texture, printers selectively deposited photopolymer material forming the outer shell of the kidney, and subsequently, an agarose gel solution was injected into the inner cavity recreating the spongier renal parenchyma. We constructed seven models of renal units with suspected malignancies. Partial nephrectomy and renorrhaphy were performed on each of the replicas. Subsequently all patients successfully underwent robotic partial nephrectomy. Average tumor diameter was 4.4 cm, warm ischemia time was 25 min, RENAL nephrometry score was 7.4, and surgical margins were negative. A comparison was made between the seven cases and the Tulane Urology prospectively maintained robotic partial nephrectomy database. Patients with surgical models had larger tumors, higher nephrometry score, longer warm ischemic time, fewer positive surgical margins, shorter hospitalization, and fewer post-operative complications; however, the only significant finding was lower estimated blood loss (186 cc vs 236; p = 0.01). In this feasibility study, pre-operative resectable physical 3D models can be constructed and used as patient-specific surgical simulation tools; further study will need to demonstrate if this results in improvement of surgical outcomes and robotic simulation education.

  4. From 2D to 3D turbulence through 2D3C configurations

    Science.gov (United States)

    Buzzicotti, Michele; Biferale, Luca; Linkmann, Moritz

    2017-11-01

    We study analytically and numerically the geometry of the nonlinear interactions and the resulting energy transfer directions of 2D3C flows. Through a set of suitably designed Direct Numerical Simulations we also study the coupling between several 2D3C flows, where we explore the transition between 2D and fully 3D turbulence. In particular, we find that the coupling of three 2D3C flows on mutually orthogonal planes subject to small-scale forcing leads to a stationary 3D out-of-equilibrium dynamics at the energy containing scales where the inverse cascade is directly balanced by a forward cascade carried by a different subsets of interactions. ERC AdG Grant No 339032 NewTURB.

  5. Measurement of the Time-Dependent CP Asymmetry of Partially Reconstructed B0 to D*+D*- Decays

    Energy Technology Data Exchange (ETDEWEB)

    Lees, J. P.

    2012-08-13

    We present a new measurement of the time-dependent CP asymmetry of B{sup 0} {yields}D*{sup +}D*{sup -} decays using (471 {+-} 5) million B{bar B} pairs collected with the BABAR detector at the PEP-II B Factory at the SLAC National Accelerator Laboratory. Using the technique of partial reconstruction, we measure the time-dependent CP asymmetry parameters S = -0.34 {+-} 0.12 {+-} 0.05 and C = +0:15 {+-} 0.09 {+-} 0.04. Using the value for the CP-odd fraction R{perpendicular} = 0.158 {+-} 0.028 {+-} 0.006, previously measured by BABAR with fully reconstructed B{sup 0} {yields} D{sup *+}D{sup *-} events, we extract the CP-even components S{sub +} = -0.49 {+-} 0.18 {+-} 0.07 {+-} 0.04 and C{sub +} = +0.15 {+-} 0.09 {+-} 0.04. In each case, the first uncertainty is statistical and the second is systematic; the third uncertainty on S{sub +} is the contribution from the uncertainty on R{perpendicular}. The measured value of the CP-even component S{sub +} is consistent with the value of sin 2{beta} measured in b {yields} (c{bar c})s transitions, and with the Standard Model expectation of small penguin contributions.

  6. 3D Space Shift from CityGML LoD3-Based Multiple Building Elements to a 3D Volumetric Object

    Directory of Open Access Journals (Sweden)

    Shen Ying

    2017-01-01

    Full Text Available In contrast with photorealistic visualizations, urban landscape applications, and building information system (BIM, 3D volumetric presentations highlight specific calculations and applications of 3D building elements for 3D city planning and 3D cadastres. Knowing the precise volumetric quantities and the 3D boundary locations of 3D building spaces is a vital index which must remain constant during data processing because the values are related to space occupation, tenure, taxes, and valuation. To meet these requirements, this paper presents a five-step algorithm for performing a 3D building space shift. This algorithm is used to convert multiple building elements into a single 3D volumetric building object while maintaining the precise volume of the 3D space and without changing the 3D locations or displacing the building boundaries. As examples, this study used input data and building elements based on City Geography Markup Language (CityGML LoD3 models. This paper presents a method for 3D urban space and 3D property management with the goal of constructing a 3D volumetric object for an integral building using CityGML objects, by fusing the geometries of various building elements. The resulting objects possess true 3D geometry that can be represented by solid geometry and saved to a CityGML file for effective use in 3D urban planning and 3D cadastres.

  7. Conservation Laws for Partially Conservative Variable Mass Systems via d'Alembert's Principle

    International Nuclear Information System (INIS)

    Ahmed, Aftab; Ahmed, Naseer; Khan, Qudrat

    2008-01-01

    Conservation laws for partially conservative variable mass dynamical systems under symmetric infinitesimal transformations are determined. A generalization of Lagrange-d'Alembert's principle for a variable mass system in terms of asynchronous virtual variation is presented. The generalized Killing equations are obtained such that their solution yields the transformations and the associated conservation laws. An example illustrative of the theory is furnished at the end as well. (the physics of elementary particles and fields)

  8. Effect of 24,25-dihydroxyvitamin D3 on 1,25-dihydroxyvitamin D3 [1,25-(OH)2D3] metabolism in vitamin D-deficient rats infused with 1,25-(OH)2D3

    International Nuclear Information System (INIS)

    Yamato, H.; Matsumoto, T.; Fukumoto, S.; Ikeda, K.; Ishizuka, S.; Ogata, E.

    1989-01-01

    Previous studies revealed that administration of 24,25-dihydroxyvitamin D3 [24,25-(OH)2D3] to calcium (Ca)-deficient rats causes a dose-dependent reduction in markedly elevated serum 1,25-(OH)2D3 level. Although the results suggested that the metabolism of 1,25-(OH)2D3 was accelerated by 24,25-(OH)2D3, those experiments could not define whether the enhanced metabolism of 1,25-(OH)2D3 played a role in the reduction in the serum 1,25-(OH)2D3 level. In the present study, in order to address this issue more specifically, serum 1,25-(OH)2D3 was maintained solely by exogenous administration through miniosmotic pumps of 1,25-(OH)2D3 into vitamin D-deficient rats. Thus, by measuring the serum 1,25-(OH)2D3 concentration, the effect of 24,25-(OH)2D3 on the MCR of 1,25-(OH)2D3 could be examined. Administration of 24,25-(OH)2D3 caused a dose-dependent enhancement in the MCR of 1,25-(OH)2D3, and 1 microgram/100 g rat.day 24,25-(OH)2D3, which elevated serum 24,25-(OH)2D3 to 8.6 +/- 1.3 ng/ml, significantly increased MCR and suppressed serum levels of 1,25-(OH)2D3. The effect of 24,25-(OH)2D3 on 1,25-(OH)2D3 metabolism developed with a rapid time course, and the recovery of iv injected [1 beta-3H]1,25-(OH)2D3 in blood was significantly reduced within 1 h. In addition, there was an increase in radioactivity in the water-soluble fraction of serum as well as in urine, suggesting that 1,25-(OH)2D3 is rapidly degraded to a water-soluble metabolite(s). Furthermore, the reduction in serum 1,25-(OH)2D3 was associated with a reduction in both serum and urinary Ca levels. Because the conversion of [3H]24,25-(OH)2D3 to [3H]1,24,25-(OH)2D3 or other metabolites was minimal in these rats, 24,25-(OH)2D3 appears to act without being converted into other metabolites. These results demonstrate that 24,25-(OH)2D3 rapidly stimulates the metabolism of 1,25-(OH)2D3 and reduces its serum level

  9. RAG-3D: a search tool for RNA 3D substructures

    Science.gov (United States)

    Zahran, Mai; Sevim Bayrak, Cigdem; Elmetwaly, Shereef; Schlick, Tamar

    2015-01-01

    To address many challenges in RNA structure/function prediction, the characterization of RNA's modular architectural units is required. Using the RNA-As-Graphs (RAG) database, we have previously explored the existence of secondary structure (2D) submotifs within larger RNA structures. Here we present RAG-3D—a dataset of RNA tertiary (3D) structures and substructures plus a web-based search tool—designed to exploit graph representations of RNAs for the goal of searching for similar 3D structural fragments. The objects in RAG-3D consist of 3D structures translated into 3D graphs, cataloged based on the connectivity between their secondary structure elements. Each graph is additionally described in terms of its subgraph building blocks. The RAG-3D search tool then compares a query RNA 3D structure to those in the database to obtain structurally similar structures and substructures. This comparison reveals conserved 3D RNA features and thus may suggest functional connections. Though RNA search programs based on similarity in sequence, 2D, and/or 3D structural elements are available, our graph-based search tool may be advantageous for illuminating similarities that are not obvious; using motifs rather than sequence space also reduces search times considerably. Ultimately, such substructuring could be useful for RNA 3D structure prediction, structure/function inference and inverse folding. PMID:26304547

  10. Determination of the 3d34d and 3d35s configurations of Fe V

    International Nuclear Information System (INIS)

    Azarov, V.I.

    2001-01-01

    The analysis of the spectrum of four times ionized iron, Fe V, has led to the determination of the 3d 3 4d and 3d 3 5s configurations. From 975 classified lines in the region 645-1190 A we have established 123 of 168 theoretically possible 3d 3 4d levels and 26 of 38 possible 3d 3 5s levels. The estimated accuracy of values of energy levels of these two configurations is about 0.7 cm -1 and 1.0 cm -1 , respectively. The level structure of the system of the 3d 4 , 3d 3 4s, 3d 3 4d and 3d 3 5s configurations has been theoretically interpreted and the energy parameters have been determined by a least squares fit to the observed levels. A comparison of parameters in Cr III and Fe V ions is given. (orig.)

  11. Treatment of Occluded Distal Splenorenal Shunts with Endovascular Stents: A Report of Two Cases

    International Nuclear Information System (INIS)

    Lopez-Medina, Antonio; Peiro, Javier; Gonzalez de Garay, Miguel; Antonana, Miguel A.; Sustacha, Jon; Grande, Domingo

    2001-01-01

    Surgical treatment of an occluded or stenotic portosystemic shunt is difficult and carries a high risk of mortality. We report two cases of early thrombosis of distal splenorenal shunt (DSRS) successfully treated by transcatheter recanalization and stent placement. At 18-month follow-up, the patients remained asymptomatic and control venograms showed continued patency of the shunt with no evidence of stenosis or collaterals

  12. Partial wave analysis of anti pp → anti ΛΛ

    International Nuclear Information System (INIS)

    Bugg, D.V.

    2004-01-01

    A partial wave analysis of PS185 data for anti pp → anti ΛΛ is presented. A 3 S 1 cusp is identified in the inverse process anti ΛΛ→ anti p p at threshold, using detailed balance to deduce cross sections from anti pp → anti ΛΛ. Partial wave amplitudes for anti pp 3 P 0 , 3 F 3 , 3 D 3 and 3 G 3 exhibit a behaviour very similar to resonances observed in Crystal Barrel data. With this identification, the anti pp → anti ΛΛ data then provide evidence for a new I=0, J PC =1 - resonance with mass M = 2290 ±20 MeV, Γ= 275 ±35 MeV, coupling to both 3 S 1 and 3 D 1 . (orig.)

  13. Effect of Task-Correlated Physiological Fluctuations and Motion in 2D and 3D Echo-Planar Imaging in a Higher Cognitive Level fMRI Paradigm.

    Science.gov (United States)

    Ladstein, Jarle; Evensmoen, Hallvard R; Håberg, Asta K; Kristoffersen, Anders; Goa, Pål E

    2016-01-01

    To compare 2D and 3D echo-planar imaging (EPI) in a higher cognitive level fMRI paradigm. In particular, to study the link between the presence of task-correlated physiological fluctuations and motion and the fMRI contrast estimates from either 2D EPI or 3D EPI datasets, with and without adding nuisance regressors to the model. A signal model in the presence of partly task-correlated fluctuations is derived, and predictions for contrast estimates with and without nuisance regressors are made. Thirty-one healthy volunteers were scanned using 2D EPI and 3D EPI during a virtual environmental learning paradigm. In a subgroup of 7 subjects, heart rate and respiration were logged, and the correlation with the paradigm was evaluated. FMRI analysis was performed using models with and without nuisance regressors. Differences in the mean contrast estimates were investigated by analysis-of-variance using Subject, Sequence, Day, and Run as factors. The distributions of group level contrast estimates were compared. Partially task-correlated fluctuations in respiration, heart rate and motion were observed. Statistically significant differences were found in the mean contrast estimates between the 2D EPI and 3D EPI when using a model without nuisance regressors. The inclusion of nuisance regressors for cardiorespiratory effects and motion reduced the difference to a statistically non-significant level. Furthermore, the contrast estimate values shifted more when including nuisance regressors for 3D EPI compared to 2D EPI. The results are consistent with 3D EPI having a higher sensitivity to fluctuations compared to 2D EPI. In the presence partially task-correlated physiological fluctuations or motion, proper correction is necessary to get expectation correct contrast estimates when using 3D EPI. As such task-correlated physiological fluctuations or motion is difficult to avoid in paradigms exploring higher cognitive functions, 2D EPI seems to be the preferred choice for higher

  14. Crime event 3D reconstruction based on incomplete or fragmentary evidence material--case report.

    Science.gov (United States)

    Maksymowicz, Krzysztof; Tunikowski, Wojciech; Kościuk, Jacek

    2014-09-01

    Using our own experience in 3D analysis, the authors will demonstrate the possibilities of 3D crime scene and event reconstruction in cases where originally collected material evidence is largely insufficient. The necessity to repeat forensic evaluation is often down to the emergence of new facts in the course of case proceedings. Even in cases when a crime scene and its surroundings have undergone partial or complete transformation, with regard to elements significant to the course of the case, or when the scene was not satisfactorily secured, it is still possible to reconstruct it in a 3D environment based on the originally-collected, even incomplete, material evidence. In particular cases when no image of the crime scene is available, its partial or even full reconstruction is still potentially feasible. Credibility of evidence for such reconstruction can still satisfy the evidence requirements in court. Reconstruction of the missing elements of the crime scene is still possible with the use of information obtained from current publicly available databases. In the study, we demonstrate that these can include Google Maps(®*), Google Street View(®*) and available construction and architecture archives. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Rhythmic neural activity indicates the contribution of attention and memory to the processing of occluded movements in 10-month-old infants.

    Science.gov (United States)

    Bache, Cathleen; Kopp, Franziska; Springer, Anne; Stadler, Waltraud; Lindenberger, Ulman; Werkle-Bergner, Markus

    2015-11-01

    Infants possess the remarkable capacity to perceive occluded movements as ongoing and coherent. Little is known about the neural mechanisms that enable internal representation of conspecifics' and inanimate objects' movements during visual occlusion. In this study, 10-month-old infants watched briefly occluded human and object movements. Prior to occlusion, continuous and distorted versions of the movement were shown. EEG recordings were used to assess neural activity assumed to relate to processes of attention (occipital alpha), memory (frontal theta), and sensorimotor simulation (central alpha) before, during, and after occlusion. Oscillatory activity was analyzed using an individualized data approach taking idiosyncrasies into account. Results for occipital alpha were consistent with infants' preference for attending to social stimuli. Furthermore, frontal theta activity was more pronounced when tracking distorted as opposed to continuous movement, and when maintaining object as opposed to human movement. Central alpha did not discriminate between experimental conditions. In sum, we conclude that observing occluded movements recruits processes of attention and memory which are modulated by stimulus and movement properties. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Axionic D3-D7 Inflation

    CERN Document Server

    Burgess, C P; Postma, M

    2009-01-01

    We study the motion of a D3 brane moving within a Type IIB string vacuum compactified to 4D on K3 x T_2/Z_2 in the presence of D7 and O7 planes. We work within the effective 4D supergravity describing how the mobile D3 interacts with the lightest bulk moduli of the compactification, including the effects of modulus-stabilizing fluxes. We seek inflationary solutions to the resulting equations, performing our search numerically in order to avoid resorting to approximate parameterizations of the low-energy potential. We consider uplifting from D-terms and from the supersymmetry-breaking effects of anti-D3 branes. We find examples of slow-roll inflation (with anti-brane uplifting) with the mobile D3 moving along the toroidal directions, falling towards a D7-O7 stack starting from the antipodal point. The inflaton turns out to be a linear combination of the brane position and the axionic partner of the K3 volume modulus, and the similarity of the potential along the inflaton direction with that of racetrack inflat...

  17. Partial monosomy 8q and partial trisomy 9q due to the maternal translocation t(8;9(q24.3;q34.1)

    DEFF Research Database (Denmark)

    Tos, T; Alp, M Y; Eker, H K

    2014-01-01

    Partial trisomy 9q34-qter and partial monosomy 8q24.3-qter are very rare chromosomal abnormalities. Characteristic features of partial trisomy 9q34-qter are hypotonia, developmental delay, mild intellectual disability, dolichocephaly, distinct facial phenotype, long and thin fingers, and cardiac...

  18. 3D Volume Rendering and 3D Printing (Additive Manufacturing).

    Science.gov (United States)

    Katkar, Rujuta A; Taft, Robert M; Grant, Gerald T

    2018-07-01

    Three-dimensional (3D) volume-rendered images allow 3D insight into the anatomy, facilitating surgical treatment planning and teaching. 3D printing, additive manufacturing, and rapid prototyping techniques are being used with satisfactory accuracy, mostly for diagnosis and surgical planning, followed by direct manufacture of implantable devices. The major limitation is the time and money spent generating 3D objects. Printer type, material, and build thickness are known to influence the accuracy of printed models. In implant dentistry, the use of 3D-printed surgical guides is strongly recommended to facilitate planning and reduce risk of operative complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. 3D object-oriented image analysis in 3D geophysical modelling

    DEFF Research Database (Denmark)

    Fadel, I.; van der Meijde, M.; Kerle, N.

    2015-01-01

    Non-uniqueness of satellite gravity interpretation has traditionally been reduced by using a priori information from seismic tomography models. This reduction in the non-uniqueness has been based on velocity-density conversion formulas or user interpretation of the 3D subsurface structures (objects......) based on the seismic tomography models and then forward modelling these objects. However, this form of object-based approach has been done without a standardized methodology on how to extract the subsurface structures from the 3D models. In this research, a 3D object-oriented image analysis (3D OOA......) approach was implemented to extract the 3D subsurface structures from geophysical data. The approach was applied on a 3D shear wave seismic tomography model of the central part of the East African Rift System. Subsequently, the extracted 3D objects from the tomography model were reconstructed in the 3D...

  20. Verification of photon attenuation characteristics for 3D printer based small animal lung model

    International Nuclear Information System (INIS)

    Lee, Se Ho; Lee, Seung Wook; Han, Su Chul; Park, Seung Woo

    2016-01-01

    Since it is difficult to measure absorbed dose to mice in vivo, replica mice are mostly used as alternative. In this study, realistic mouse phantom was fabricated by using 3D printer (object500 connex3, Stratasys, USA). Elemental inks as material of 3D printer were selected corresponding to mouse tissue. To represent lung, selected material was partially used with air layer. In order to verify material equivalent, super-flex bolus was simply compared to verify photon attenuation characteristics. In the case of lung, Hounsfield unit (HU) of the phantom were compared with a live mouse. In this study, we fabricated mouse phantom by using 3D printer, and practically verified photon attenuation characteristics. The fabricated phantom shows tissue equivalence as well as similar geometry with live mouse. As more and more growing of 3D printer technique, 3D printer based small preclinical animal phantom would increase reliability of verification of absorbed dose in small animal for preclinical study

  1. Verification of photon attenuation characteristics for 3D printer based small animal lung model

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Se Ho; Lee, Seung Wook [Pusan National University, Busan (Korea, Republic of); Han, Su Chul; Park, Seung Woo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2016-05-15

    Since it is difficult to measure absorbed dose to mice in vivo, replica mice are mostly used as alternative. In this study, realistic mouse phantom was fabricated by using 3D printer (object500 connex3, Stratasys, USA). Elemental inks as material of 3D printer were selected corresponding to mouse tissue. To represent lung, selected material was partially used with air layer. In order to verify material equivalent, super-flex bolus was simply compared to verify photon attenuation characteristics. In the case of lung, Hounsfield unit (HU) of the phantom were compared with a live mouse. In this study, we fabricated mouse phantom by using 3D printer, and practically verified photon attenuation characteristics. The fabricated phantom shows tissue equivalence as well as similar geometry with live mouse. As more and more growing of 3D printer technique, 3D printer based small preclinical animal phantom would increase reliability of verification of absorbed dose in small animal for preclinical study.

  2. Development of vitamin D3 25-hydroxylase activity in rat liver microsomes

    International Nuclear Information System (INIS)

    Thierry-Palmer, M.; Cullins, S.; Rashada, S.; Gray, T.K.; Free, A.

    1986-01-01

    The authors have determined the ontogeny of vitamin D 3 25-hydroxylase activity in rat liver microsomes. Microsomes from fetuses, neonates, and their mothers were incubated with 44 nM 3 H-vitamin D 3 in the presence of an NADPH generating system, oxygen, KCl, and MgCl 2 . Lipid extracts of the incubation samples were partially purified by thin-layer chromatography. Tritiated 25-hydroxy vitamin D 3 (250HD 3 ) was analyzed by high-pressure liquid chromatography using 94/6 hexane/isopropanol. Production rate for 250HD 3 in the mothers ranged from 0.22 to 0.30 pmol/mg protein/hr. Activities in the fetuses and neonates were 2.1, 12.9, 32.0, 35.8, and 71.0% of that of their mothers at -3, 0, 2, 7, and 15 days of age. The cytosolic fraction protected the substrate from degradation, stimulated the vitamin D 3 25-hydroxylase reaction in neonates and mothers (1.4 to 1.7 fold increase), and was absolutely required for 25-hydroxylase activity in fetuses. These data suggest that microsomal vitamin D 3 25-hydroxylase activity develops slowly and approaches full activity near the weaning stage. A cytosolic factor present as early as -3 days of age stimulates the activity of the microsomal vitamin D 3 25-hydroxylase

  3. Computational partial differential equations using Matlab

    CERN Document Server

    Li, Jichun

    2008-01-01

    Brief Overview of Partial Differential Equations The parabolic equations The wave equations The elliptic equations Differential equations in broader areasA quick review of numerical methods for PDEsFinite Difference Methods for Parabolic Equations Introduction Theoretical issues: stability, consistence, and convergence 1-D parabolic equations2-D and 3-D parabolic equationsNumerical examples with MATLAB codesFinite Difference Methods for Hyperbolic Equations IntroductionSome basic difference schemes Dissipation and dispersion errors Extensions to conservation lawsThe second-order hyperbolic PDE

  4. Complications Following Balloon-Occluded Arterial Infusion Chemotherapy for Pelvic Malignancies

    International Nuclear Information System (INIS)

    Sugimoto, Koji; Hirota, Shozo; Imanaka, Kazufumi; Kawabe, Tetsuya; Nakayama, Yoshiharu; Takeuchi, Yasuhito

    1999-01-01

    Purpose: To evaluate the incidence and causes of complications associated with balloon-occluded arterial infusion chemotherapy (BOAI) for pelvic malignancies. Methods: In 34 courses of BOAI in 22 patients with pelvic malignancies, we analyzed the incidence of complications as well as the effect of the dose of the anticancer drugs, the infusion site, and the number of BOAI administrations on these complications. Complications were divided into two categories: cystitis-like symptoms and neurological complications such as pain, numbness, and paresthesia of the lower extremities and the hip. Results: Eleven patients (50%) suffered from complications, seven (31.8%) from neurological complications and four (18.2%) from cystitis-like symptoms. The complications appeared in 14 courses (42.4%) of BOAI, neurological complications in 10 (30.3%) and cystitis-like symptoms in four (12.1%). A high dose of anti-cancer drugs and infusion from the anterior division tended to induce neurological complications more frequently; however, the cystitis-like symptoms were not related to any factors. Conclusion: Our results indicate that a smaller dose of anti-cancer drugs should be infused from the bilateral internal iliac arteries for safer pelvic BOAI

  5. Cryopreserved recombinant tissue plasminogen activator for the restoration of occluded central venous access devices in pediatric oncology patients

    International Nuclear Information System (INIS)

    Iqbal, Y.; Al-Katheri, A.; Al-Sedairy, R.; Al-Omari, A.; Abdullah, Mohammed F.; Crankson, S.

    2002-01-01

    Thrombolytic therapy with urokinase 5000 units has been the standard therapy for restoration of thrombosed central catheters. However, with the decreased availability of urokinase, alternatives needed to be sought. The aim of the study was to determine the efficacy, bioactivity, dwell time and cost of cryopreserved recombinant tissue plasminogen activator (rTPA) in the restoration of occluded central venous access devices. For children 10kg, a dose of 1 mg was used. The dwell time was 1-2 hours. Of the 40 courses of rTPA, 39 fully restored central venous line patency (97%). Successful courses were instilled for an average of 1 hour. Cryopreserved rTPA appears to be safe and effective in the dose used to restore the patency of occluded central venous access devices in pediatric oncology patients. (author)

  6. 3D IBFV : Hardware-Accelerated 3D Flow Visualization

    NARCIS (Netherlands)

    Telea, Alexandru; Wijk, Jarke J. van

    2003-01-01

    We present a hardware-accelerated method for visualizing 3D flow fields. The method is based on insertion, advection, and decay of dye. To this aim, we extend the texture-based IBFV technique for 2D flow visualization in two main directions. First, we decompose the 3D flow visualization problem in a

  7. 3D IBFV : hardware-accelerated 3D flow visualization

    NARCIS (Netherlands)

    Telea, A.C.; Wijk, van J.J.

    2003-01-01

    We present a hardware-accelerated method for visualizing 3D flow fields. The method is based on insertion, advection, and decay of dye. To this aim, we extend the texture-based IBFV technique presented by van Wijk (2001) for 2D flow visualization in two main directions. First, we decompose the 3D

  8. FPFH-based graph matching for 3D point cloud registration

    Science.gov (United States)

    Zhao, Jiapeng; Li, Chen; Tian, Lihua; Zhu, Jihua

    2018-04-01

    Correspondence detection is a vital step in point cloud registration and it can help getting a reliable initial alignment. In this paper, we put forward an advanced point feature-based graph matching algorithm to solve the initial alignment problem of rigid 3D point cloud registration with partial overlap. Specifically, Fast Point Feature Histograms are used to determine the initial possible correspondences firstly. Next, a new objective function is provided to make the graph matching more suitable for partially overlapping point cloud. The objective function is optimized by the simulated annealing algorithm for final group of correct correspondences. Finally, we present a novel set partitioning method which can transform the NP-hard optimization problem into a O(n3)-solvable one. Experiments on the Stanford and UWA public data sets indicates that our method can obtain better result in terms of both accuracy and time cost compared with other point cloud registration methods.

  9. Immunogenicity and T cell recognition in swine of foot-and-mouth disease virus polymerase 3D

    International Nuclear Information System (INIS)

    Garcia-Briones, Maria M.; Blanco, Esther; Chiva, Cristina; Andreu, David; Ley, Victoria; Sobrino, Francisco

    2004-01-01

    Immunization of domestic pigs with a vaccinia virus (VV) recombinant expressing foot-and-mouth disease virus (FMDV) 3D protein conferred partial protection against challenge with infectious virus. The severity reduction of the clinical symptoms developed by the challenged animals occurred in the absence of significant levels of anti-3D circulating antibodies. This observation suggested that the partial protection observed was mediated by the induction of a 3D-specific cellular immune response. To gain information on the T cell recognition of FMDV 3D protein, we conducted in vitro proliferative assays using lymphocytes from outbred pigs experimentally infected with FMDV and 90 overlapping peptides spanning the complete 3D sequence. The use of pools of two to three peptides allowed the identification of T cell epitopes that were efficiently recognized by lymphocytes from at least four of the five animals analyzed. This recognition was heterotypic because anti-peptide responses increased upon reinfection of animals with a FMDV isolate from a different serotype. The results obtained with individual peptides confirmed the antigenicity observed with peptide pools. Detection of cytokine mRNAs by RT-PCR in lymphocytes stimulated in vitro by individual 3D peptides revealed that IFN-γ mRNA was the most consistently induced, suggesting that the activated T cells belong to the Th 1 subset. These results indicate that 3D protein contains epitopes that can be efficiently recognized by porcine T lymphocytes from different infected animals, both upon primary and secondary (heterotypic) FMDV infection. These epitopes can extend the repertoire of viral T cell epitopes to be included in subunit and synthetic FMD vaccines

  10. SAMPL5: 3D-RISM partition coefficient calculations with partial molar volume corrections and solute conformational sampling

    Science.gov (United States)

    Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C.; Joyce, Kevin P.; Kovalenko, Andriy

    2016-11-01

    Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing (R=0.98 for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining R=0.73 compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to R=0.93. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple pK_{ {a}} correction improved agreement with experiment from R=0.54 to R=0.66, despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.

  11. SAMPL5: 3D-RISM partition coefficient calculations with partial molar volume corrections and solute conformational sampling.

    Science.gov (United States)

    Luchko, Tyler; Blinov, Nikolay; Limon, Garrett C; Joyce, Kevin P; Kovalenko, Andriy

    2016-11-01

    Implicit solvent methods for classical molecular modeling are frequently used to provide fast, physics-based hydration free energies of macromolecules. Less commonly considered is the transferability of these methods to other solvents. The Statistical Assessment of Modeling of Proteins and Ligands 5 (SAMPL5) distribution coefficient dataset and the accompanying explicit solvent partition coefficient reference calculations provide a direct test of solvent model transferability. Here we use the 3D reference interaction site model (3D-RISM) statistical-mechanical solvation theory, with a well tested water model and a new united atom cyclohexane model, to calculate partition coefficients for the SAMPL5 dataset. The cyclohexane model performed well in training and testing ([Formula: see text] for amino acid neutral side chain analogues) but only if a parameterized solvation free energy correction was used. In contrast, the same protocol, using single solute conformations, performed poorly on the SAMPL5 dataset, obtaining [Formula: see text] compared to the reference partition coefficients, likely due to the much larger solute sizes. Including solute conformational sampling through molecular dynamics coupled with 3D-RISM (MD/3D-RISM) improved agreement with the reference calculation to [Formula: see text]. Since our initial calculations only considered partition coefficients and not distribution coefficients, solute sampling provided little benefit comparing against experiment, where ionized and tautomer states are more important. Applying a simple [Formula: see text] correction improved agreement with experiment from [Formula: see text] to [Formula: see text], despite a small number of outliers. Better agreement is possible by accounting for tautomers and improving the ionization correction.

  12. Cortical dynamics of three-dimensional figure-ground perception of two-dimensional pictures.

    Science.gov (United States)

    Grossberg, S

    1997-07-01

    This article develops the FACADE theory of 3-dimensional (3-D) vision and figure-ground separation to explain data concerning how 2-dimensional pictures give rise to 3-D percepts of occluding and occluded objects. The model describes how geometrical and contrastive properties of a picture can either cooperate or compete when forming the boundaries and surface representation that subserve conscious percepts. Spatially long-range cooperation and spatially short-range competition work together to separate the boundaries of occluding figures from their occluded neighbors. This boundary ownership process is sensitive to image T junctions at which occluded figures contact occluding figures. These boundaries control the filling-in of color within multiple depth-sensitive surface representations. Feedback between surface and boundary representations strengthens consistent boundaries while inhibiting inconsistent ones. Both the boundary and the surface representations of occluded objects may be amodally completed, while the surface representations of unoccluded objects become visible through modal completion. Functional roles for conscious modal and amodal representations in object recognition, spatial attention, and reaching behaviors are discussed. Model interactions are interpreted in terms of visual, temporal, and parietal cortices.

  13. A software tool for automatic classification and segmentation of 2D/3D medical images

    International Nuclear Information System (INIS)

    Strzelecki, Michal; Szczypinski, Piotr; Materka, Andrzej; Klepaczko, Artur

    2013-01-01

    Modern medical diagnosis utilizes techniques of visualization of human internal organs (CT, MRI) or of its metabolism (PET). However, evaluation of acquired images made by human experts is usually subjective and qualitative only. Quantitative analysis of MR data, including tissue classification and segmentation, is necessary to perform e.g. attenuation compensation, motion detection, and correction of partial volume effect in PET images, acquired with PET/MR scanners. This article presents briefly a MaZda software package, which supports 2D and 3D medical image analysis aiming at quantification of image texture. MaZda implements procedures for evaluation, selection and extraction of highly discriminative texture attributes combined with various classification, visualization and segmentation tools. Examples of MaZda application in medical studies are also provided

  14. A software tool for automatic classification and segmentation of 2D/3D medical images

    Energy Technology Data Exchange (ETDEWEB)

    Strzelecki, Michal, E-mail: michal.strzelecki@p.lodz.pl [Institute of Electronics, Technical University of Lodz, Wolczanska 211/215, 90-924 Lodz (Poland); Szczypinski, Piotr; Materka, Andrzej; Klepaczko, Artur [Institute of Electronics, Technical University of Lodz, Wolczanska 211/215, 90-924 Lodz (Poland)

    2013-02-21

    Modern medical diagnosis utilizes techniques of visualization of human internal organs (CT, MRI) or of its metabolism (PET). However, evaluation of acquired images made by human experts is usually subjective and qualitative only. Quantitative analysis of MR data, including tissue classification and segmentation, is necessary to perform e.g. attenuation compensation, motion detection, and correction of partial volume effect in PET images, acquired with PET/MR scanners. This article presents briefly a MaZda software package, which supports 2D and 3D medical image analysis aiming at quantification of image texture. MaZda implements procedures for evaluation, selection and extraction of highly discriminative texture attributes combined with various classification, visualization and segmentation tools. Examples of MaZda application in medical studies are also provided.

  15. Acute D2/D3 dopaminergic agonism but chronic D2/D3 antagonism prevents NMDA antagonist neurotoxicity.

    Science.gov (United States)

    Farber, Nuri B; Nemmers, Brian; Noguchi, Kevin K

    2006-09-15

    Antagonists of the N-methyl-D-aspartate (NMDA) glutamate receptor, most likely by producing disinhibtion in complex circuits, acutely produce psychosis and cognitive disturbances in humans, and neurotoxicity in rodents. Studies examining NMDA Receptor Hypofunction (NRHypo) neurotoxicity in animals, therefore, may provide insights into the pathophysiology of psychotic disorders. Dopaminergic D2 and/or D3 agents can modify psychosis over days to weeks, suggesting involvement of these transmitter system(s). We studied the ability of D2/D3 agonists and antagonists to modify NRHypo neurotoxicity both after a one-time acute exposure and after chronic daily exposure. Here we report that D2/D3 dopamine agonists, probably via D3 receptors, prevent NRHypo neurotoxicity when given acutely. The protective effect with D2/D3 agonists is not seen after chronic daily dosing. In contrast, the antipsychotic haloperidol does not affect NRHypo neurotoxicity when given acutely at D2/D3 doses. However, after chronic daily dosing of 1, 3, or 5 weeks, haloperidol does prevent NRHypo neurotoxicity with longer durations producing greater protection. Understanding the changes that occur in the NRHypo circuit after chronic exposure to dopaminergic agents could provide important clues into the pathophysiology of psychotic disorders.

  16. Balloon-occluded Retrograde Transvenous Obliteration (BRTO): Technique and Intraprocedural Imaging

    Science.gov (United States)

    Sabri, Saher S.; Saad, Wael E. A.

    2011-01-01

    Balloon-occluded retrograde transvenous obliteration (BRTO) is an endovascular technique used as a therapeutic adjunct or alternative to transjugular intrahepatic shunts (TIPS) in the management of gastric varices. Occlusion balloons are strategically placed to modulate flow within the gastrorenal or gastrocaval shunt to allow stagnation of the sclerosant material within the gastric varix. The approach and complexity of the procedure depends on the anatomic classification of inflow and outflow veins of the varix. Ethanolamine oleate has been described as the main sclerosant used in this procedure. Recently, foam sclerosants have gained popularity as alternative embolization agents, which provide the advantage of better variceal wall contact and potentially less dose of sclerosant. PMID:22942548

  17. Targeting the dopamine D3 receptor: an overview of drug design strategies.

    Science.gov (United States)

    Cortés, Antoni; Moreno, Estefanía; Rodríguez-Ruiz, Mar; Canela, Enric I; Casadó, Vicent

    2016-07-01

    Dopamine is a neurotransmitter widely distributed in both the periphery and the central nervous system (CNS). Its physiological effects are mediated by five closely related G protein-coupled receptors (GPCRs) that are divided into two major subclasses: the D1-like (D1, D5) and the D2-like (D2, D3, D4) receptors. D3 receptors (D3Rs) have the highest density in the limbic areas of the brain, which are associated with cognitive and emotional functions. These receptors are therefore attractive targets for therapeutic management. This review summarizes the functional and pharmacological characteristics of D3Rs, including the design and clinical relevance of full agonists, partial agonists and antagonists, as well as the capacity of these receptors to form active homodimers, heterodimers or higher order receptor complexes as pharmacological targets in several neurological and neurodegenerative disorders. The high sequence homology between D3R and the D2-type challenges the development of D3R-selective compounds. The design of new D3R-preferential ligands with improved physicochemical properties should provide a better pharmacokinetic/bioavailability profile and lesser toxicity than is found with existing D3R ligands. It is also essential to optimize D3R affinity and, especially, D3R vs. D2-type binding and functional selectivity ratios. Developing allosteric and bitopic ligands should help to improve the D3R selectivity of these drugs. As most evidence points to the ability of GPCRs to form homomers and heteromers, the most promising therapeutic strategy in the future is likely to involve the application of heteromer-selective drugs. These selective ligands would display different affinities for a given receptor depending on the receptor partners within the heteromer. Therefore, designing novel compounds that specifically target and modulate D1R-D3R heteromers would be an interesting approach for the treatment of levodopa (L-DOPA)-induced dyskinesias.

  18. Parallel Optimization of 3D Cardiac Electrophysiological Model Using GPU

    Directory of Open Access Journals (Sweden)

    Yong Xia

    2015-01-01

    Full Text Available Large-scale 3D virtual heart model simulations are highly demanding in computational resources. This imposes a big challenge to the traditional computation resources based on CPU environment, which already cannot meet the requirement of the whole computation demands or are not easily available due to expensive costs. GPU as a parallel computing environment therefore provides an alternative to solve the large-scale computational problems of whole heart modeling. In this study, using a 3D sheep atrial model as a test bed, we developed a GPU-based simulation algorithm to simulate the conduction of electrical excitation waves in the 3D atria. In the GPU algorithm, a multicellular tissue model was split into two components: one is the single cell model (ordinary differential equation and the other is the diffusion term of the monodomain model (partial differential equation. Such a decoupling enabled realization of the GPU parallel algorithm. Furthermore, several optimization strategies were proposed based on the features of the virtual heart model, which enabled a 200-fold speedup as compared to a CPU implementation. In conclusion, an optimized GPU algorithm has been developed that provides an economic and powerful platform for 3D whole heart simulations.

  19. Characterizing 3D sensors using the 3D modulation transfer function

    Science.gov (United States)

    Kellner, Timo; Breitbarth, Andreas; Zhang, Chen; Notni, Gunther

    2018-03-01

    The fields of optical 3D measurement system applications are continuously expanding and becoming more and more diverse. To evaluate appropriate systems for various measurement tasks, comparable parameters are necessary, whereas the 3D modulation transfer function (3D-MTF) has been established as a further criterion. Its aim is the determination of the system response between the measurement of a straight, sharp-edged cube and its opposite ideal calculated one. Within the scope of this work simulations and practical investigations regarding the 3D-MTF’s influences and its main issues are specifically investigated. Therefore, different determined edge radii representing the high-frequency spectra lead to various decreasing 3D-MTF characteristics. Furthermore, rising sampling frequencies improve its maximum transfer value to a saturation point in dependence of the radius. To approve these results of previous simulations, three fringe projection scanners were selected to determine the diversity. As the best 3D-MTF characteristic, a saturated transfer value of H_3D( f_N, 3D) = 0.79 has been identified at a sufficient sampling frequency, which is reached at four times the Nyquist limit. This high 3D resolution can mainly be achieved due to an improved camera projector interaction. Additionally, too small sampling ratios lead to uncertainties in the edge function determination, while higher ratios do not show major improvements. In conclusion, the 3D-MTF algorithm has thus been practically verified and its repeatability as well as its robustness have been confirmed.

  20. Different chemical composition of free light, occluded light and extractable SOM fractions in soils of Cerrado and tilled and untilled fielfds, Minas Gerais, Brazil: a pyrolysis-GC/MS study

    NARCIS (Netherlands)

    Buurman, P.; Roscob, R.

    2011-01-01

    To investigate both the effect of land-use systems on SOM characteristics and the effect of occlusion in aggregates on chemical composition of the occluded fraction, SOM fractions of soils under Cerrado, no-tillage and conventional tillage, were investigated. Free light, occluded light and

  1. Transcatheter Retrieval of Embolized Atrial Septal Defect Occluder Device by Waist Capture Technique.

    Science.gov (United States)

    Her, Ae-Young; Lim, Kyung-Hun; Shin, Eun-Seok

    2018-01-27

    This case study describes the successful percutaneous transcatheter retrieval of an embolized Amplatzer occluder device using the "waist capture technique" in a patient with an atrial septal defect. This technique allowed for stability of the Amplatzer device, compression of the atrial discs for easier removal, prevention of further embolization, and minimal injury to vasculature during device retrieval. This novel and effective technique can be used safely for the retrieval of Amplatzer devices in the venous system.

  2. Aspects of defects in 3d-3d correspondence

    International Nuclear Information System (INIS)

    Gang, Dongmin; Kim, Nakwoo; Romo, Mauricio; Yamazaki, Masahito

    2016-01-01

    In this paper we study supersymmetric co-dimension 2 and 4 defects in the compactification of the 6d (2,0) theory of type A_N_−_1 on a 3-manifold M. The so-called 3d-3d correspondence is a relation between complexified Chern-Simons theory (with gauge group SL(N,ℂ)) on M and a 3d N=2 theory T_N[M]. We study this correspondence in the presence of supersymmetric defects, which are knots/links inside the 3-manifold. Our study employs a number of different methods: state-integral models for complex Chern-Simons theory, cluster algebra techniques, domain wall theory T[SU(N)], 5d N=2 SYM, and also supergravity analysis through holography. These methods are complementary and we find agreement between them. In some cases the results lead to highly non-trivial predictions on the partition function. Our discussion includes a general expression for the cluster partition function, which can be used to compute in the presence of maximal and certain class of non-maximal punctures when N>2. We also highlight the non-Abelian description of the 3d N=2T_N[M] theory with defect included, when such a description is available. This paper is a companion to our shorter paper http://dx.doi.org/10.1088/1751-8113/49/30/30LT02, which summarizes our main results.

  3. Measurement of partial widths and search for direct CP violation in D0 meson decays to K-K+ and pi-pi+.

    Science.gov (United States)

    Acosta, D; Affolder, T; Akimoto, T; Albrow, M G; Ambrose, D; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arisawa, T; Arguin, J-F; Artikov, A; Ashmanskas, W; Attal, A; Azfar, F; Azzi-Bacchetta, P; Bacchetta, N; Bachacou, H; Badgett, W; Barbaro-Galtieri, A; Barker, G J; Barnes, V E; Barnett, B A; Baroiant, S; Barone, M; Bauer, G; Bedeschi, F; Behari, S; Belforte, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Binkley, M; Bisello, D; Bishai, M; Blair, R E; Blocker, C; Bloom, K; Blumenfeld, B; Bocci, A; Bodek, A; Bolla, G; Bolshov, A; Booth, P S L; Bortoletto, D; Boudreau, J; Bourov, S; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Byrum, K L; Cabrera, S; Calafiura, P; Campanelli, M; Campbell, M; Canepa, A; Casarsa, M; Carlsmith, D; Carron, S; Carosi, R; Cavalli-Sforza, M; Castro, A; Catastini, P; Cauz, D; Cerri, A; Cerri, C; Cerrito, L; Chapman, J; Chen, C; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chu, M L; Chuang, S; Chung, J Y; Chung, W-H; Chung, Y S; Ciobanu, C I; Ciocci, M A; Clark, A G; Clark, D; Coca, M; Connolly, A; Convery, M; Conway, J; Cooper, B; Cordelli, M; Cortiana, G; Cranshaw, J; Cuevas, J; Culbertson, R; Currat, C; Cyr, D; Dagenhart, D; Da Ronco, S; D'Auria, S; de Barbaro, P; De Cecco, S; De Lentdecker, G; Dell'agnello, S; Dell'orso, M; Demers, S; Demortier, L; Deninno, M; De Pedis, D; Derwent, P F; Dionisi, C; Dittmann, J R; Doksus, P; Dominguez, A; Donati, S; Donega, M; Donini, J; D'Onofrio, M; Dorigo, T; Drollinger, V; Ebina, K; Eddy, N; Ely, R; Erbacher, R; Erdmann, M; Errede, D; Errede, S; Eusebi, R; Fang, H-C; Farrington, S; Fedorko, I; Feild, R G; Feindt, M; Fernandez, J P; Ferretti, C; Field, R D; Fiori, I; Flanagan, G; Flaugher, B; Flores-Castillo, L R; Foland, A; Forrester, S; Foster, G W; Franklin, M; Freeman, J; Frisch, H; Fujii, Y; Furic, I; Gajjar, A; Gallas, A; Galyardt, J; Gallinaro, M; Garcia-Sciveres, M; Garfinkel, A F; Gay, C; Gerberich, H; Gerdes, D W; Gerchtein, E; Giagu, S; Giannetti, P; Gibson, A; Gibson, K; Ginsburg, C; Giolo, K; Giordani, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, D; Goldstein, J; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Gotra, Y; Goulianos, K; Gresele, A; Griffiths, M; Grosso-Pilcher, C; Guenther, M; Guimaraes da Costa, J; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Handler, R; Happacher, F; Hara, K; Hare, M; Harr, R F; Harris, R M; Hartmann, F; Hatakeyama, K; Hauser, J; Hays, C; Hayward, H; Heider, E; Heinemann, B; Heinrich, J; Hennecke, M; Herndon, M; Hill, C; Hirschbuehl, D; Hocker, A; Hoffman, K D; Holloway, A; Hou, S; Houlden, M A; Huffman, B T; Huang, Y; Hughes, R E; Huston, J; Ikado, K; Incandela, J; Introzzi, G; Iori, M; Ishizawa, Y; Issever, C; Ivanov, A; Iwata, Y; Iyutin, B; James, E; Jang, D; Jarrell, J; Jeans, D; Jensen, H; Jeon, E J; Jones, M; Joo, K K; Jun, S; Junk, T; Kamon, T; Kang, J; Karagoz Unel, M; Karchin, P E; Kartal, S; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, M S; Kim, S B; Kim, S H; Kim, T H; Kim, Y K; King, B T; Kirby, M; Kirsch, L; Klimenko, S; Knuteson, B; Ko, B R; Kobayashi, H; Koehn, P; Kong, D J; Kondo, K; Konigsberg, J; Kordas, K; Korn, A; Korytov, A; Kotelnikov, K; Kotwal, A V; Kovalev, A; Kraus, J; Kravchenko, I; Kreymer, A; Kroll, J; Kruse, M; Krutelyov, V; Kuhlmann, S E; Kuznetsova, N; Laasanen, A T; Lai, S; Lami, S; Lammel, S; Lancaster, J; Lancaster, M; Lander, R; Lannon, K; Lath, A; Latino, G; Lauhakangas, R; Lazzizzera, I; Le, Y; Lecci, C; Lecompte, T; Lee, J; Lee, J; Lee, S W; Leonardo, N; Leone, S; Lewis, J D; Li, K; Lin, C; Lin, C S; Lindgren, M; Liss, T M; Litvintsev, D O; Liu, T; Liu, Y; Lockyer, N S; Loginov, A; Loreti, M; Loverre, P; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lyons, L; Lys, J; Lysak, R; Macqueen, D; Madrak, R; Maeshima, K; Maksimovic, P; Malferrari, L; Manca, G; Marginean, R; Martin, M; Martin, A; Martin, V; Martínez, M; Maruyama, T; Matsunaga, H; Mattson, M; Mazzanti, P; McFarland, K S; McGivern, D; McIntyre, P M; McNamara, P; Ncnulty, R; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; Miao, T; Miladinovic, N; Miller, L; Miller, R; Miller, J S; Miquel, R; Miscetti, S; Mitselmakher, G; Miyamoto, A; Miyazaki, Y; Moggi, N; Mohr, B; Moore, R; Morello, M; Mukherjee, A; Mulhearn, M; Muller, T; Mumford, R; Munar, A; Murat, P; Nachtman, J; Nahn, S; Nakamura, I; Nakano, I; Napier, A; Napora, R; Naumov, D; Necula, V; Niell, F; Nielsen, J; Nelson, C; Nelson, T; Neu, C; Neubauer, M S; Newman-Holmes, C; Nicollerat, A-S; Nigmanov, T; Nodulman, L; Norniella, O; Oesterberg, K; Ogawa, T; Oh, S H; Oh, Y D; Ohsugi, T; Okusawa, T; Oldeman, R; Orava, R; Orejudos, W; Pagliarone, C; Palmonari, F; Paoletti, R; Papadimitriou, V; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Pauly, T; Paus, C; Pellett, D; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pitts, K T; Plager, C; Pompos, A; Pondrom, L; Pope, G; Poukhov, O; Prakoshyn, F; Pratt, T; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Rademacker, J; Rakitine, A; Rappoccio, S; Ratnikov, F; Ray, H; Reichold, A; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Rimondi, F; Rinnert, K; Ristori, L; Robertson, W J; Robson, A; Rodrigo, T; Rolli, S; Rosenson, L; Roser, R; Rossin, R; Rott, C; Russ, J; Ruiz, A; Ryan, D; Saarikko, H; Safonov, A; St Denis, R; Sakumoto, W K; Salamanna, G; Saltzberg, D; Sanchez, C; Sansoni, A; Santi, L; Sarkar, S; Sato, K; Savard, P; Savoy-Navarro, A; Schemitz, P; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Scodellaro, L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semeria, F; Sexton-Kennedy, L; Sfiligoi, I; Shapiro, M D; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Siegrist, J; Siket, M; Sill, A; Sinervo, P; Sisakyan, A; Skiba, A; Slaughter, A J; Sliwa, K; Smirnov, D; Smith, J R; Snider, F D; Snihur, R; Somalwar, S V; Spalding, J; Spezziga, M; Spiegel, L; Spinella, F; Spiropulu, M; Squillacioti, P; Stadie, H; Stefanini, A; Stelzer, B; Stelzer-Chilton, O; Strologas, J; Stuart, D; Sukhanov, A; Sumorok, K; Sun, H; Suzuki, T; Taffard, A; Tafirout, R; Takach, S F; Takano, H; Takashima, R; Takeuchi, Y; Takikawa, K; Tanaka, M; Tanaka, R; Tanimoto, N; Tapprogge, S; Tecchio, M; Teng, P K; Terashi, K; Tesarek, R J; Tether, S; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tollefson, K; Tomura, T; Tonelli, D; Tönnesmann, M; Torre, S; Torretta, D; Trischuk, W; Tseng, J; Tsuchiya, R; Tsuno, S; Tsybychev, D; Turini, N; Turner, M; Ukegawa, F; Unverhau, T; Uozumi, S; Usynin, D; Vacavant, L; Vaiciulis, A; Varganov, A; Vataga, E; Vejcik, S; Velev, G; Veramendi, G; Vickey, T; Vidal, R; Vila, I; Vilar, R; Volobouev, I; von der Mey, M; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wallny, R; Walter, T; Yamashita, T; Yamamoto, K; Wan, Z; Wang, M J; Wang, S M; Warburton, A; Ward, B; Waschke, S; Waters, D; Watts, T; Weber, M; Wester, W C; Whitehouse, B; Wicklund, A B; Wicklund, E; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolter, M; Worcester, M; Worm, S; Wright, T; Wu, X; Würthwein, F; Wyatt, A; Yagil, A; Yang, U K; Yao, W; Yeh, G P; Yi, K; Yoh, J; Yoon, P; Yorita, K; Yoshida, T; Yu, I; Yu, S; Yu, Z; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zetti, F; Zhou, J; Zsenei, A; Zucchelli, S

    2005-04-01

    We present a measurement of relative partial widths and decay rate CP asymmetries in K-K+ and pi(-)pi(+) decays of D0 mesons produced in pp collisions at sqrt[s]=1.96 TeV. We use a sample of 2x10(5) D(*+)-->D0pi(+) (and charge conjugate) decays with the D0 decaying to K-pi(+), K-K+, and pi(-)pi(+), corresponding to 123 pb(-1) of data collected by the Collider Detector at Fermilab II experiment at the Fermilab Tevatron collider. No significant direct CP violation is observed. We measure Gamma(D0-->K-K+)/Gamma(D0-->K-pi(+))=0.0992+/-0.0011+/-0.0012, Gamma(D0-->pi(-)pi(+))/Gamma(D0-->K-pi(+))=0.035 94+/-0.000 54+/-0.000 40, A(CP)(K-K+)=(2.0+/-1.2+/-0.6)%, and A(CP)(pi(-)pi(+))=(1.0+/-1.3+/-0.6)%, where, in all cases, the first uncertainty is statistical and the second is systematic.

  4. Hepatic Encephalopathy Secondary to Intrahepatic Portosystemic Venous Shunt: Balloon-Occluded Retrograde Transvenous Embolization with n-Butyl Cyanoacrylate and Microcoils

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Nakamura, Toshiyuki; Iida, Shigeharu; Kato, Takeharu; Tanaka, Osamu; Matsushima, Shigenori; Ito, Hirotoshi; Okuyama, Chio; Ushijima, Yo; Shiga, Kensuke; Nishimura, Tsunehiko

    2002-01-01

    We report a 70-year-old woman with hepatic encephalopathy due to an intrahepatic portosystemic venous shunt that was successfully occluded by percutaneous transcatheter embolization with n-butyl cyanoacrylate and microcoils

  5. D3-??????????????????????? ? ???? ?????????? ?2 ?????? ?????? ?????

    OpenAIRE

    ?????????, ????; ???????, ???????; ??????, ?????????; ?????????????, ????; ??????, ??????

    2011-01-01

    ????? ?????? ??????? ????? ????? ??????????? ?????? ?????? ????? ? ?????? ? ???????? ????? ?????????. ?????????? ???????????? ?????? ?? ?2 ?????? ?????? ????? ??????? ?? D3 ???????????????? ??????? ??????????? ?????? ????????? ????? ?????????? ??? ??? ??????????. ? ????? ????????????? ??????????? ??? ????????? ????????????? ?????????? ???? ?????????? ?????????? ????? ????????? ?????? ???????? ?? D3-????????????????? ???????.

  6. Intraoperative closure of infant multiple muscular ventricular septal defects with Amplatzer occluder

    International Nuclear Information System (INIS)

    Liu Jinfen; Gao Wei; Zhu Zhongqun; Chen Huiwen; Zhang Yuqi

    2005-01-01

    Objective: To report the preliminary experience of intraoperative hybrid therapy for closure of multiple muscular ventricular septal defects (VSD) in a small infant. Methods: After median sternotomy, a AGA Amplatzer occluder was introduced through right ventricular surface to close 2 muscular ventricular septal defects under transesophageal echocardiographic guidance. Results: The infant survived after the treatment without residual shunting, and rehabilitated rapidly. Conclusions: Intraoperative hybrid therapy with combined surgical technique and interventional procedure for closure of multiple muscular VSD in small infant is a safe and effective method. (authors)

  7. The efficacy of incorporating partial squats in maximal strength training.

    Science.gov (United States)

    Bazyler, Caleb D; Sato, Kimitake; Wassinger, Craig A; Lamont, Hugh S; Stone, Michael H

    2014-11-01

    The purpose of our study was to examine the effects of 2 different training methods on dynamic and isometric measures of maximal strength. Seventeen recreationally trained men (1 repetition maximum [1RM] squat: 146.9 ± 22.4 kg) were assigned to 2 groups: full range of motion (ROM) squat (F) and full ROM with partial ROM squat (FP) for the 7-week training intervention. Repeated measures analysis of variance revealed that there was a statistically significant group-by-time interaction for impulse scaled at 50, 90, and 250 milliseconds at 90° of knee flexion and rate of force development at 200 milliseconds with 120° of knee flexion (p ≤ 0.05). There was also a statistically significant time effect (p ≤ 0.05) for the 1RM squat, 1RM partial squat, isometric squat peak force allometrically scaled (IPFa) 90°, IPFa 120°, and impulse allometrically scaled at 50, 90, 200, and 250 milliseconds at 90° and 120° of knee flexion. Additionally, the FP group achieved statistically larger relative training intensities (%1RM) during the final 3 weeks of training (p ≤ 0.05). There was a trend for FP to improve over F in 1RM squat (+3.1%, d = 0.53 vs. 0.32), 1RM partial squat (+4.7%, d = 0.95 vs. 0.69), IPFa 120° (+5.7%, d = 0.52 vs. 0.12), and impulse scaled at 50, 90, 200, and 250 milliseconds at 90° (+6.3 to 13.2%, d = 0.50-1.01 vs. 0.30-0.57) and 120° (+3.4 to 16.8%, d = 0.45-1.11 vs. 0.08-0.37). These larger effect sizes in the FP group can likely be explained their ability to train at larger relative training intensities during the final 3 weeks of training resulting in superior training adaptations. Our findings suggest that partial ROM squats in conjunction with full ROM squats may be an effective training method for improving maximal strength and early force-time curve characteristics in men with previous strength training experience. Practically, partial squats may be beneficial for strength and power athletes during a strength-speed mesocycle while peaking

  8. Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder.

    Science.gov (United States)

    Wang, Jou-Kou; Wu, Mei-Hwan; Lin, Ming-Tai; Chiu, Shuenn-Nan; Chen, Chun-An; Chiu, Hsin-Hui

    2010-02-01

    There are difficulties in transcatheter closure of patent ductus arteriosus (PDA) in infants. The 46 infants (mean age 6.2+/-2.7 months; mean body weight 6.3+/-1.6 kg) who underwent PDA closure using the Amplatzer duct occluder (ADO). The indication for using an ADO was a ductus diameter > or =2.5 or 3 mm. Device diameter selected was 1-3 mm larger than ductal diameter. The mean systolic pulmonary artery pressure was 40.9+/-18.2 mmHg. The mean Qp/Qs ratio was 3.1+/-1.2. The mean ductus diameter was 3.3+/-0.8 mm. ADO was successfully deployed in 45 patients. Failure occurred in 1 case. The mean diameter of device used was 5.4+/-1.1 mm. No severe complications occurred. At the 1-month echocardiographic follow-up, a small residual shunt was present in 4 of 45 patients and had disappeared in all 4 patients at the 3-month follow-up. One patient developed a moderate degree of left ventricular outflow tract obstruction 2.3 years after the procedure. Transcatheter closure of PDA in infants using the ADO is a safe and effective method.

  9. Balloon occluded retrograde transvenous obliteration of bleeding stomal varices using sodium tetradecyl sulfate foam: A case report

    International Nuclear Information System (INIS)

    Kim, Ji Chang; Yang, Po Sang; Lee, Yeon Soo; Kim, Hyun Jeong; Park, Gun

    2015-01-01

    A small varix is an uncommon complication with a high mortality rate occurring secondary to portal hypertension in patients with a stoma. We describe a case of recurrent stomal varix bleeding successfully managed by balloon occluded retrograde transvenous obliteration using sodium tetradecyl sulfate foam.

  10. Balloon occluded retrograde transvenous obliteration of bleeding stomal varices using sodium tetradecyl sulfate foam: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Chang; Yang, Po Sang; Lee, Yeon Soo; Kim, Hyun Jeong; Park, Gun [Dept. of Radiology, The Catholic University of Korea College of Medicine, Daejeon St. Mary' s Hospital, Daejeon (Korea, Republic of)

    2015-05-15

    A small varix is an uncommon complication with a high mortality rate occurring secondary to portal hypertension in patients with a stoma. We describe a case of recurrent stomal varix bleeding successfully managed by balloon occluded retrograde transvenous obliteration using sodium tetradecyl sulfate foam.

  11. Visualization of the lower cranial nerves by 3D-FIESTA

    International Nuclear Information System (INIS)

    Okumura, Yusuke; Suzuki, Masayuki; Takemura, Akihiro; Tsujii, Hideo; Kawahara, Kazuhiro; Matsuura, Yukihiro; Takada, Tadanori

    2005-01-01

    MR cisternography has been introduced for use in neuroradiology. This method is capable of visualizing tiny structures such as blood vessels and cranial nerves in the cerebrospinal fluid (CSF) space because of its superior contrast resolution. The cranial nerves and small vessels are shown as structures of low intensity surrounded by marked hyperintensity of the CSF. In the present study, we evaluated visualization of the lower cranial nerves (glossopharyngeal, vagus, and accessory) by the three-dimensional fast imaging employing steady-state acquisition (3D-FIESTA) sequence and multiplanar reformation (MPR) technique. The subjects were 8 men and 3 women, ranging in age from 21 to 76 years (average, 54 yeas). We examined the visualization of a total of 66 nerves in 11 subjects by 3D-FIESTA. The results were classified into four categories ranging from good visualization to non-visualization. In all cases, all glossopharyngeal and vagus nerves were identified to some extent, while accessory nerves were visualized either partially or entirely in only 16 cases. The total visualization rate was about 91%. In conclusion, 3D-FIESTA may be a useful method for visualization of the lower cranial nerves. (author)

  12. Photoaffinity labeling of serum vitamin D binding protein by 3-deoxy-3-azido-25-hydroxyvitamin D3

    International Nuclear Information System (INIS)

    Link, R.P.; Kutner, A.; Schnoes, H.K.; DeLuca, H.F.

    1987-01-01

    3-Deoxy-3-azido-25-hydroxyvitamin D3 was covalently incorporated in the 25-hydroxyvitamin D3 binding site of purified human plasma vitamin D binding protein. Competition experiments showed that 3-deoxy-3-azido-25-hydroxyvitamin D3 and 25-hydroxyvitamin D3 bind at the same site on the protein. Tritiated 3-deoxy-3-azido-25-hydroxyvitamin D3 was synthesized from tritiated 25-hydroxyvitamin D3, retaining the high specific activity of the parent compound. The tritiated azido label bound reversibly to human vitamin D binding protein in the dark and covalently to human vitamin D binding protein after exposure to ultraviolet light. Reversible binding of tritiated 3-deoxy-3-azido-25-hydroxyvitamin D3 was compared to tritiated 25-hydroxyvitamin D3 binding to human vitamin D binding protein. Scatchard analysis of the data indicated equivalent maximum density binding sites with a KD,app of 0.21 nM for 25-hydroxyvitamin D3 and a KD,app of 1.3 nM for the azido derivative. Covalent binding was observed only after exposure to ultraviolet irradiation, with an average of 3% of the reversibly bound label becoming covalently bound to vitamin D binding protein. The covalent binding was reduced 70-80% when 25-hydroxyvitamin D3 was present, indicating strong covalent binding at the vitamin D binding site of the protein. When tritiated 3-deoxy-3-azido-25-hydroxyvitamin D3 was incubated with human plasma in the absence and presence of 25-hydroxyvitamin D3, 12% of the azido derivative was reversibly bound to vitamin D binding protein. After ultraviolet irradiation, four plasma proteins covalently bound the azido label, but vitamin D binding protein was the only protein of the four that was unlabeled in the presence of 25-hydroxyvitamin D3

  13. Biomechanical comparison of two different collar structured implants supporting 3-unit fixed partial denture: a 3-D FEM study.

    Science.gov (United States)

    Meriç, Gökçe; Erkmen, Erkan; Kurt, Ahmet; Eser, Atilim; Ozden, Ahmet Utku

    2012-01-01

    The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.

  14. 3D for free using the Mac's standard apps : converting raw 3D text files to QuickDraw 3D's 3DMF format using AppleScript

    NARCIS (Netherlands)

    Djajadiningrat, J.P.

    2003-01-01

    This article introduces you to the basics of 3D files in general and the 3D Metafile (3DMF), QuickDraw 3D's native 3D format, in particular. It shows how you can use AppleScript to easily convert a raw 3D text file into a 3DMF readable by the QuickDraw 3D Viewer or any other QuickDraw 3D compatible

  15. Global Value Chains from a 3D Printing Perspective

    DEFF Research Database (Denmark)

    Laplume, André O; Petersen, Bent; Pearce, Joshua M.

    2016-01-01

    This article outlines the evolution of additive manufacturing technology, culminating in 3D printing and presents a vision of how this evolution is affecting existing global value chains (GVCs) in production. In particular, we bring up questions about how this new technology can affect...... the geographic span and density of GVCs. Potentially, wider adoption of this technology has the potential to partially reverse the trend towards global specialization of production systems into elements that may be geographically dispersed and closer to the end users (localization). This leaves the question...

  16. 3D Elevation Program—Virtual USA in 3D

    Science.gov (United States)

    Lukas, Vicki; Stoker, J.M.

    2016-04-14

    The U.S. Geological Survey (USGS) 3D Elevation Program (3DEP) uses a laser system called ‘lidar’ (light detection and ranging) to create a virtual reality map of the Nation that is very accurate. 3D maps have many uses with new uses being discovered all the time.  

  17. Metric-like formalism for matter fields coupled to 3D higher spin gravity

    Science.gov (United States)

    Fujisawa, Ippei; Nakayama, Ryuichi

    2014-12-01

    The action integral for a matter system composed of 0- and 2-forms, C and Bμν, topologically coupled to 3D spin-3 gravity is considered first in the frame-like formalism. The field C satisfies an equation of motion, \\partial _{\\mu } \\, C+A_{\\mu } \\, C-C \\, \\bar{A}_{\\mu }=0, where Aμ and \\bar{A}_{\\mu } are the Chern-Simons gauge fields. With a suitable gauge fixing of a new local symmetry and diffeomorphism, only one component of Bμν, say Bϕr, remains non-vanishing and satisfies \\partial _{\\mu } \\, B_{\\phi r}+\\bar{A}_{\\mu } \\, B_{\\phi r}-B_{\\phi r} \\, A_{\\mu }=0. These equations are the same as those for 3D (free) Vasiliev scalars, C and \\tilde{C}. The spin connection is eliminated by solving the equation of motion for the total action, and it is shown that in the resulting metric-like formalism, (BC)2 interaction terms are induced because of the torsion. The world-volume components of the matter field, C0, Cμ and C(μν), are introduced by contracting the local-frame index of C with those of the inverse vielbeins, E_a^{\\mu } and E_a^{(\\mu \

  18. 3D Animation Essentials

    CERN Document Server

    Beane, Andy

    2012-01-01

    The essential fundamentals of 3D animation for aspiring 3D artists 3D is everywhere--video games, movie and television special effects, mobile devices, etc. Many aspiring artists and animators have grown up with 3D and computers, and naturally gravitate to this field as their area of interest. Bringing a blend of studio and classroom experience to offer you thorough coverage of the 3D animation industry, this must-have book shows you what it takes to create compelling and realistic 3D imagery. Serves as the first step to understanding the language of 3D and computer graphics (CG)Covers 3D anim

  19. 3DSEM: A 3D microscopy dataset

    Directory of Open Access Journals (Sweden)

    Ahmad P. Tafti

    2016-03-01

    Full Text Available The Scanning Electron Microscope (SEM as a 2D imaging instrument has been widely used in many scientific disciplines including biological, mechanical, and materials sciences to determine the surface attributes of microscopic objects. However the SEM micrographs still remain 2D images. To effectively measure and visualize the surface properties, we need to truly restore the 3D shape model from 2D SEM images. Having 3D surfaces would provide anatomic shape of micro-samples which allows for quantitative measurements and informative visualization of the specimens being investigated. The 3DSEM is a dataset for 3D microscopy vision which is freely available at [1] for any academic, educational, and research purposes. The dataset includes both 2D images and 3D reconstructed surfaces of several real microscopic samples. Keywords: 3D microscopy dataset, 3D microscopy vision, 3D SEM surface reconstruction, Scanning Electron Microscope (SEM

  20. An in vivo assessment of the effects of using different implant abutment occluding materials on implant microleakage and the peri-implant microbiome

    Science.gov (United States)

    Rubino, Caroline

    Microleakage may be a factor in the progression of peri-implant pathology. Microleakage in implant dentistry refers to the passage of bacteria, fluids, molecules or ions between the abutment-implant interface to and from the surrounding periodontal tissues. This creates a zone of inflammation and reservoir of bacteria at the implant-abutment interface. Bone loss typically occurs within the first year of abutment connection and then stabilizes. It has not yet been definitively proven that the occurrence of microleakage cannot contribute to future bone loss or impede the treatment of peri-implant disease. Therefore, strategies to reduce or eliminate microleakage are sought out. Recent evidence demonstrates that the type of implant abutment channel occluding material can affect the amount of microleakage in an in vitro study environment. Thus, we hypothesize that different abutment screw channel occluding materials will affect the amount of observed microleakage, vis-a-vis the correlation between the microflora found on the abutment screw channel occluding material those found in the peri-implant sulcus. Additional objectives include confirming the presence of microleakage in vivo and assessing any impact that different abutment screw channel occluding materials may have on the peri-implant microbiome. Finally, the present study provides an opportunity to further characterize the peri-implant microbiome. Eight fully edentulous patients restored with at dental implants supporting screw-retained fixed hybrid prostheses were included in the study. At the initial appointment (T1), the prostheses were removed and the implants and prostheses were cleaned. The prostheses were then inserted with polytetrafluoroethylene tape (PTFE, TeflonRTM), cotton, polyvinyl siloxane (PVS), or synthetic foam as the implant abutment channel occluding material and sealed over with composite resin. About six months later (T2), the prostheses were removed and the materials collected. Paper

  1. Phase correction for three-dimensional (3D) diffusion-weighted interleaved EPI using 3D multiplexed sensitivity encoding and reconstruction (3D-MUSER).

    Science.gov (United States)

    Chang, Hing-Chiu; Hui, Edward S; Chiu, Pui-Wai; Liu, Xiaoxi; Chen, Nan-Kuei

    2018-05-01

    Three-dimensional (3D) multiplexed sensitivity encoding and reconstruction (3D-MUSER) algorithm is proposed to reduce aliasing artifacts and signal corruption caused by inter-shot 3D phase variations in 3D diffusion-weighted echo planar imaging (DW-EPI). 3D-MUSER extends the original framework of multiplexed sensitivity encoding (MUSE) to a hybrid k-space-based reconstruction, thereby enabling the correction of inter-shot 3D phase variations. A 3D single-shot EPI navigator echo was used to measure inter-shot 3D phase variations. The performance of 3D-MUSER was evaluated by analyses of point-spread function (PSF), signal-to-noise ratio (SNR), and artifact levels. The efficacy of phase correction using 3D-MUSER for different slab thicknesses and b-values were investigated. Simulations showed that 3D-MUSER could eliminate artifacts because of through-slab phase variation and reduce noise amplification because of SENSE reconstruction. All aliasing artifacts and signal corruption in 3D interleaved DW-EPI acquired with different slab thicknesses and b-values were reduced by our new algorithm. A near-whole brain single-slab 3D DTI with 1.3-mm isotropic voxel acquired at 1.5T was successfully demonstrated. 3D phase correction for 3D interleaved DW-EPI data is made possible by 3D-MUSER, thereby improving feasible slab thickness and maximum feasible b-value. Magn Reson Med 79:2702-2712, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. EUROPEANA AND 3D

    Directory of Open Access Journals (Sweden)

    D. Pletinckx

    2012-09-01

    Full Text Available The current 3D hype creates a lot of interest in 3D. People go to 3D movies, but are we ready to use 3D in our homes, in our offices, in our communication? Are we ready to deliver real 3D to a general public and use interactive 3D in a meaningful way to enjoy, learn, communicate? The CARARE project is realising this for the moment in the domain of monuments and archaeology, so that real 3D of archaeological sites and European monuments will be available to the general public by 2012. There are several aspects to this endeavour. First of all is the technical aspect of flawlessly delivering 3D content over all platforms and operating systems, without installing software. We have currently a working solution in PDF, but HTML5 will probably be the future. Secondly, there is still little knowledge on how to create 3D learning objects, 3D tourist information or 3D scholarly communication. We are still in a prototype phase when it comes to integrate 3D objects in physical or virtual museums. Nevertheless, Europeana has a tremendous potential as a multi-facetted virtual museum. Finally, 3D has a large potential to act as a hub of information, linking to related 2D imagery, texts, video, sound. We describe how to create such rich, explorable 3D objects that can be used intuitively by the generic Europeana user and what metadata is needed to support the semantic linking.

  3. Dopamine D2 receptor radiotracers [11C](+)-PHNO and [3H]raclopride are indistinguishably inhibited by D2 agonists and antagonists ex vivo

    International Nuclear Information System (INIS)

    McCormick, Patrick N.; Kapur, Shitij; Seeman, Philip; Wilson, Alan A.

    2008-01-01

    Introduction: In vitro, the dopamine D2 receptor exists in two states, with high and low affinity for agonists. The high-affinity state is the physiologically active state thought to be involved in dopaminergic illnesses such as schizophrenia. The positron emission tomography radiotracer [ 11 C](+)-PHNO ([ 11 C](+)-4-propyl-3,4,4a,5,6,10b-hexahydro-2H-naphtho[1,2-b][1,4] oxazin-9-o l), being a D2 agonist, should selectively label the high-affinity state at tracer dose and therefore be more susceptible to competition by agonist as compared to the antagonist [ 3 H]raclopride, which binds to both affinity states. Methods: We tested this prediction using ex vivo dual-radiotracer experiments in conscious rats. D2 antagonists (haloperidol or clozapine), a partial agonist (aripiprazole), a full agonist [(-)-NPA] or the dopamine-releasing drug amphetamine (AMPH) were administered to rats prior to an intravenous coinjection of [ 11 C](+)-PHNO and [ 3 H]raclopride. Rats were sacrificed 60 min after radiotracer injection. Striatum, cerebellum and plasma samples were counted for 11 C and 3 H. The specific binding ratio {SBR, i.e., [%ID/g (striatum)-%ID/g (cerebellum)]/(%ID/g (cerebellum)} was used as the outcome measure. Results: In response to D2 antagonists, partial agonist or full agonist, [ 11 C](+)-PHNO and [ 3 H]raclopride SBRs responded indistinguishably in terms of both ED 50 and Hill slope (e.g., (-)-NPA ED 50 values are 0.027 and 0.023 mg/kg for [ 11 C](+)-PHNO and [ 3 H]raclopride, respectively). In response to AMPH challenge, [ 11 C](+)-PHNO and [ 3 H]raclopride SBRs were inhibited to the same degree. Conclusions: We have shown that the SBRs of [ 11 C](+)-PHNO- and [ 3 H]raclopride do not differ in their response to agonist challenge. These results do not support predictions of the in vivo binding behavior of a D2 agonist radiotracer and cast some doubt on the in vivo applicability of the D2 two-state model, as described by in vitro binding experiments

  4. Multispectroscopic methods reveal different modes of interaction of anti cancer drug mitoxantrone with Poly(dG-dC).Poly(dG-dC) and Poly(dA-dT).Poly(dA-dT).

    Science.gov (United States)

    Awasthi, Pamita; Dogra, Shilpa; Barthwal, Ritu

    2013-10-05

    The interaction of mitoxantrone with alternating Poly(dG-dC).Poly(dG-dC) and Poly(dA-dT).Poly(dA-dT) duplex has been studied by absorption, fluorescence and Circular Dichroism (CD) spectroscopy at Drug to Phosphate base pair ratios D/P=20.0-0.04. Binding to GC polymer occurs in two distinct modes: partial stacking characterized by red shifts of 18-23nm at D/P=0.2-0.8 and external binding at D/P=1.0-20.0 whereas that to AT polymer occurs externally in the entire range of D/P. The binding constant and number of binding sites is 3.7×10(5)M(-1), 0.3 and 1.3× 10(4)M(-1), 1.5 in GC and AT polymers, respectively at low D/P ratios. CD binding isotherms show breakpoints at D/P=0.1, 0.5 and 0.25, 0.5 in GC and AT polymers, respectively. The intrinsic CD bands indicate that the distortions in GC polymer are significantly higher than that in AT polymer. Docking studies show partial insertion of mitoxantrone rings between to GC base pairs in alternating GC polymer. Side chains of mitoxantrone interact specifically with base pairs and DNA backbone. The studies are relevant to the understanding of suppression or inhibition of DNA cleavage on formation of ternary complex with topoisomerase-II enzyme and hence the anti cancer action. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. PPARγ partial agonist GQ-16 strongly represses a subset of genes in 3T3-L1 adipocytes

    Energy Technology Data Exchange (ETDEWEB)

    Milton, Flora Aparecida [Faculdade de Ciências da Saúde, Laboratório de Farmacologia Molecular, Universidade de Brasília (Brazil); Genomic Medicine, Houston Methodist Research Institute, Houston, TX (United States); Cvoro, Aleksandra [Genomic Medicine, Houston Methodist Research Institute, Houston, TX (United States); Amato, Angelica A. [Faculdade de Ciências da Saúde, Laboratório de Farmacologia Molecular, Universidade de Brasília (Brazil); Sieglaff, Douglas H.; Filgueira, Carly S.; Arumanayagam, Anithachristy Sigamani [Genomic Medicine, Houston Methodist Research Institute, Houston, TX (United States); Caro Alves de Lima, Maria do; Rocha Pitta, Ivan [Laboratório de Planejamento e Síntese de Fármacos – LPSF, Universidade Federal de Pernambuco (Brazil); Assis Rocha Neves, Francisco de [Faculdade de Ciências da Saúde, Laboratório de Farmacologia Molecular, Universidade de Brasília (Brazil); Webb, Paul, E-mail: pwebb@HoustonMethodist.org [Genomic Medicine, Houston Methodist Research Institute, Houston, TX (United States)

    2015-08-28

    Thiazolidinediones (TZDs) are peroxisome proliferator-activated receptor gamma (PPARγ) agonists that improve insulin resistance but trigger side effects such as weight gain, edema, congestive heart failure and bone loss. GQ-16 is a PPARγ partial agonist that improves glucose tolerance and insulin sensitivity in mouse models of obesity and diabetes without inducing weight gain or edema. It is not clear whether GQ-16 acts as a partial agonist at all PPARγ target genes, or whether it displays gene-selective actions. To determine how GQ-16 influences PPARγ activity on a gene by gene basis, we compared effects of rosiglitazone (Rosi) and GQ-16 in mature 3T3-L1 adipocytes using microarray and qRT-PCR. Rosi changed expression of 1156 genes in 3T3-L1, but GQ-16 only changed 89 genes. GQ-16 generally showed weak effects upon Rosi induced genes, consistent with partial agonist actions, but a subset of modestly Rosi induced and strongly repressed genes displayed disproportionately strong GQ-16 responses. PPARγ partial agonists MLR24 and SR1664 also exhibit disproportionately strong effects on transcriptional repression. We conclude that GQ-16 displays a continuum of weak partial agonist effects but efficiently represses some negatively regulated PPARγ responsive genes. Strong repressive effects could contribute to physiologic actions of GQ-16. - Highlights: • GQ-16 is an insulin sensitizing PPARγ ligand with reduced harmful side effects. • GQ-16 displays a continuum of weak partial agonist activities at PPARγ-induced genes. • GQ-16 exerts strong repressive effects at a subset of genes. • These inhibitor actions should be evaluated in models of adipose tissue inflammation.

  6. PPARγ partial agonist GQ-16 strongly represses a subset of genes in 3T3-L1 adipocytes

    International Nuclear Information System (INIS)

    Milton, Flora Aparecida; Cvoro, Aleksandra; Amato, Angelica A.; Sieglaff, Douglas H.; Filgueira, Carly S.; Arumanayagam, Anithachristy Sigamani; Caro Alves de Lima, Maria do; Rocha Pitta, Ivan; Assis Rocha Neves, Francisco de; Webb, Paul

    2015-01-01

    Thiazolidinediones (TZDs) are peroxisome proliferator-activated receptor gamma (PPARγ) agonists that improve insulin resistance but trigger side effects such as weight gain, edema, congestive heart failure and bone loss. GQ-16 is a PPARγ partial agonist that improves glucose tolerance and insulin sensitivity in mouse models of obesity and diabetes without inducing weight gain or edema. It is not clear whether GQ-16 acts as a partial agonist at all PPARγ target genes, or whether it displays gene-selective actions. To determine how GQ-16 influences PPARγ activity on a gene by gene basis, we compared effects of rosiglitazone (Rosi) and GQ-16 in mature 3T3-L1 adipocytes using microarray and qRT-PCR. Rosi changed expression of 1156 genes in 3T3-L1, but GQ-16 only changed 89 genes. GQ-16 generally showed weak effects upon Rosi induced genes, consistent with partial agonist actions, but a subset of modestly Rosi induced and strongly repressed genes displayed disproportionately strong GQ-16 responses. PPARγ partial agonists MLR24 and SR1664 also exhibit disproportionately strong effects on transcriptional repression. We conclude that GQ-16 displays a continuum of weak partial agonist effects but efficiently represses some negatively regulated PPARγ responsive genes. Strong repressive effects could contribute to physiologic actions of GQ-16. - Highlights: • GQ-16 is an insulin sensitizing PPARγ ligand with reduced harmful side effects. • GQ-16 displays a continuum of weak partial agonist activities at PPARγ-induced genes. • GQ-16 exerts strong repressive effects at a subset of genes. • These inhibitor actions should be evaluated in models of adipose tissue inflammation

  7. Synthesis of mixed-valent {alpha}- and {beta}-NaFe{sub 2}O{sub 3} polymorphs under controlled partial oxygen pressure

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, Shaun R.; Blakely, Colin K. [Department of Chemistry, Michigan State University, East Lansing, MI 48824 (United States); Poltavets, Viktor V., E-mail: poltavets@chemistry.msu.edu [Department of Chemistry, Michigan State University, East Lansing, MI 48824 (United States)

    2012-08-15

    Synthesis of mixed valent compounds, especially when multiple polymorphs exist, requires careful control of the preparation conditions. {alpha}- and {beta}-NaFe{sub 2}O{sub 3} polymorphs were synthesized under controlled partial oxygen pressure (pO{sub 2}). pO{sub 2} regions of stability at 850 Degree-Sign C were determined for both phases for the first time. A modified oxygen buffer method was developed for the facile preparation of mixed valent oxides under controlled pO{sub 2}. {beta}-NaFe{sub 2}O{sub 3} is the only known n=2 member of the AM{sub n}O{sub n+1} (A=alkali metal, M=3d metal) rock-salt related homolog series with layered cation ordering. The possibility of new members of the homolog series with other 3d metals is considered. - Graphical abstract: Schematic section of phase composition vs. partial O{sub 2} pressure diagram at 850 Degree-Sign C for Na/Fe=1/2 and structure models of {alpha}- and {beta}-NaFe{sub 2}O{sub 3}. Highlights: Black-Right-Pointing-Pointer {alpha}- and {beta}-NaFe{sub 2}O{sub 3} polymorphs were synthesized under controlled oxygen pressure. Black-Right-Pointing-Pointer {beta}-NaFe{sub 2}O{sub 3} has rock-salt related structure with layered cation ordering. Black-Right-Pointing-Pointer Existence of the rock-salt related homolog series AM{sub n}O{sub n+1} is discussed.

  8. Results of the combined U.S. Multicenter Pivotal Study and the Continuing Access Study of the Nit-Occlud PDA device for percutaneous closure of patent ductus arteriosus.

    Science.gov (United States)

    Moore, John W; Greene, Jessica; Palomares, Salvadore; Javois, Alexander; Owada, Carl Y; Cheatham, John P; Hoyer, Mark H; Jones, Thomas K; Levi, Daniel S

    2014-12-01

    This study aimed to compare the efficacy and safety of the Nit-Occlud PDA device (PFM Medical, Cologne, Germany) to benchmarks designed as objective performance criteria (OPC). The Nit-Occlud PDA is a nitinol coil-type patent ductus arteriosus (PDA) occluder with a reverse cone configuration, which is implanted using a controlled delivery system. Patients with closure (clinical and echocardiographic), and safety criteria incidence of adverse events (serious and of total). The Pivotal Study enrolled patients between November 1, 2002 and October 31, 2005, and the Continuing Access Study enrolled additional patients between September 1, 2006 and October 31, 2007. A total of 357 patients were enrolled, and 347 had successful device implantations. After 12 months, 96.8% had complete echocardiographic closure (OPC = 85%) and 98.1% had clinical closure (OPC = 95%). There were no deaths or serious adverse events (OPC = 1%). The total adverse event rate was 4.7% (OPC = 6%). Composite success was 95.1% in the study patients (OPC = 80%). Closure of small- and medium-sized PDA with the Nit-Occlud PDA is effective and safe when compared with OPC. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Real-Time 3D Tracking and Reconstruction on Mobile Phones.

    Science.gov (United States)

    Prisacariu, Victor Adrian; Kähler, Olaf; Murray, David W; Reid, Ian D

    2015-05-01

    We present a novel framework for jointly tracking a camera in 3D and reconstructing the 3D model of an observed object. Due to the region based approach, our formulation can handle untextured objects, partial occlusions, motion blur, dynamic backgrounds and imperfect lighting. Our formulation also allows for a very efficient implementation which achieves real-time performance on a mobile phone, by running the pose estimation and the shape optimisation in parallel. We use a level set based pose estimation but completely avoid the, typically required, explicit computation of a global distance. This leads to tracking rates of more than 100 Hz on a desktop PC and 30 Hz on a mobile phone. Further, we incorporate additional orientation information from the phone's inertial sensor which helps us resolve the tracking ambiguities inherent to region based formulations. The reconstruction step first probabilistically integrates 2D image statistics from selected keyframes into a 3D volume, and then imposes coherency and compactness using a total variational regularisation term. The global optimum of the overall energy function is found using a continuous max-flow algorithm and we show that, similar to tracking, the integration of per voxel posteriors instead of likelihoods improves the precision and accuracy of the reconstruction.

  10. Ionic rotational branching ratios in resonant enhanced multiphoton ionization of NO via the A 2Σ+(3sσ) and D 2Σ+(3pσ) states

    International Nuclear Information System (INIS)

    Rudolph, H.; Dixit, S.N.; McKoy, V.; Huo, W.M.

    1988-01-01

    We present the results of ab initio calculations of the ionic rotational branching ratios in NO for a (1+1) REMPI (resonant enhanced multiphoton ionization) via the A 2 Σ + (3sσ) state and a (2+1) REMPI via the D 2 Σ + (3pσ) state. Despite the atomic-like character of the bound 3sσ and 3pσ orbitals in these resonant states, the photoelectron continuum exhibits strong l mixing. The selection rule ΔN+l = odd (ΔNequivalentN/sub +/-N/sub i/) implies that the peaks in the photoelectron spectrum corresponding to ΔN = odd ( +- 1, +- 3) are sensitive to even partial waves while those corresponding to even ΔN probe the odd partial waves in the photoelectron continuum. Recent experimental high resolution photoelectron studies have shown a strong ΔN = 0 peak for ionization via the A 2 Σ + and the D 2 Σ + states, indicating a dominance of odd-l partial waves. While this seems natural for ionization out of the 3sσ orbital, it is quite anomalous for 3pσ ionization. Based on extensive bound calculations, Viswanathan et al. [J. Phys. Chem. 90, 5078 (1986)] attribute this anomaly to a strong l mixing in the electronic continuum caused by the nonspherical molecular potential

  11. From 3D view to 3D print

    Science.gov (United States)

    Dima, M.; Farisato, G.; Bergomi, M.; Viotto, V.; Magrin, D.; Greggio, D.; Farinato, J.; Marafatto, L.; Ragazzoni, R.; Piazza, D.

    2014-08-01

    In the last few years 3D printing is getting more and more popular and used in many fields going from manufacturing to industrial design, architecture, medical support and aerospace. 3D printing is an evolution of bi-dimensional printing, which allows to obtain a solid object from a 3D model, realized with a 3D modelling software. The final product is obtained using an additive process, in which successive layers of material are laid down one over the other. A 3D printer allows to realize, in a simple way, very complex shapes, which would be quite difficult to be produced with dedicated conventional facilities. Thanks to the fact that the 3D printing is obtained superposing one layer to the others, it doesn't need any particular work flow and it is sufficient to simply draw the model and send it to print. Many different kinds of 3D printers exist based on the technology and material used for layer deposition. A common material used by the toner is ABS plastics, which is a light and rigid thermoplastic polymer, whose peculiar mechanical properties make it diffusely used in several fields, like pipes production and cars interiors manufacturing. I used this technology to create a 1:1 scale model of the telescope which is the hardware core of the space small mission CHEOPS (CHaracterising ExOPlanets Satellite) by ESA, which aims to characterize EXOplanets via transits observations. The telescope has a Ritchey-Chrétien configuration with a 30cm aperture and the launch is foreseen in 2017. In this paper, I present the different phases for the realization of such a model, focusing onto pros and cons of this kind of technology. For example, because of the finite printable volume (10×10×12 inches in the x, y and z directions respectively), it has been necessary to split the largest parts of the instrument in smaller components to be then reassembled and post-processed. A further issue is the resolution of the printed material, which is expressed in terms of layers

  12. Vitamin D3 and 25-hydroxyvitamin D3 in pork and their relationship to vitamin D status in pigs

    DEFF Research Database (Denmark)

    Burild, Anders; Lauridsen, Charlotte; Faqir, Nasrin

    2016-01-01

    The content of vitamin D in pork produced in conventional systems depends on the vitamin D concentration in the pig feed. Both vitamin D3 and 25-hydroxyvitamin D3 (25(OH)D3) are essential sources of dietary vitamin D; however, bioavailability assessed by serum 25(OH)D3 concentration is reported...... of vitamin D3 and 25(OH)D3 in the pig feed for 49 d before slaughter. Concurrently, the 25(OH)D3 level in serum was investigated as a biomarker to assess the content of vitamin D3 and 25(OH)D3 in pig tissues. Adipose tissue, white and red muscle, the liver and serum were sampled from pigs fed feed containing...... either vitamin D3 or 25(OH)D3 at 5, 20, 35 or 50 µg/kg feed for 7 weeks before slaughter. The tissue 25(OH)D3 level was significantly higher in the pigs fed 25(OH)D3 compared with those fed vitamin D3, while the tissue vitamin D3 level was higher in the pigs fed vitamin D3 compared with those fed 25(OH...

  13. Mutagenesis by alkylating agents: coding properties for DNA polymerase of poly (dC) template containing 3-methylcytosine

    Energy Technology Data Exchange (ETDEWEB)

    Boiteux, S.; Laval, J. (Institut Gustave-Roussy, 94 - Villejuif (France))

    After treatment of poly(dC) by the simple alkylating agent (/sup 3/H)dimethylsulfate, 90 percent of the radioactivity cochromatographed with 3-methylcytosine and 10 percent with 5-methylcytosine which is the normally occurring methylated base. In order to study the influence of 3-methylcytosine on DNA replication, untreated and MDS-treated poly(dC) were used as templates for E. coli DNA polymerase I. The alkylation of poly(dC) inhibits DNA chain elongation, and does not induce any mispairing under high fidelity conditions. The alteration of DNA polymerase I fidelity by manganese ions allows some replication of 3-methylcytosine which mispairs with either dAMP or dTMP. Our results suggest that 3-methylcytosine could be responsible, at least partially, for killing and the mutagenesis observed after cell treatment by alkylating agents.

  14. Accelerated 3D-OSEM image reconstruction using a Beowulf PC cluster for pinhole SPECT

    International Nuclear Information System (INIS)

    Zeniya, Tsutomu; Watabe, Hiroshi; Sohlberg, Antti; Iida, Hidehiro

    2007-01-01

    A conventional pinhole single-photon emission computed tomography (SPECT) with a single circular orbit has limitations associated with non-uniform spatial resolution or axial blurring. Recently, we demonstrated that three-dimensional (3D) images with uniform spatial resolution and no blurring can be obtained by complete data acquired using two-circular orbit, combined with the 3D ordered subsets expectation maximization (OSEM) reconstruction method. However, a long computation time is required to obtain the reconstruction image, because of the fact that 3D-OSEM is an iterative method and two-orbit acquisition doubles the size of the projection data. To reduce the long reconstruction time, we parallelized the two-orbit pinhole 3D-OSEM reconstruction process by using a Beowulf personal computer (PC) cluster. The Beowulf PC cluster consists of seven PCs connected to Gbit Ethernet switches. Message passing interface protocol was utilized for parallelizing the reconstruction process. The projection data in a subset are distributed to each PC. The partial image forward-and back-projected in each PC is transferred to all PCs. The current image estimate on each PC is updated after summing the partial images. The performance of parallelization on the PC cluster was evaluated using two independent projection data sets acquired by a pinhole SPECT system with two different circular orbits. Parallelization using the PC cluster improved the reconstruction time with increasing number of PCs. The reconstruction time of 54 min by the single PC was decreased to 10 min when six or seven PCs were used. The speed-up factor was 5.4. The reconstruction image by the PC cluster was virtually identical with that by the single PC. Parallelization of 3D-OSEM reconstruction for pinhole SPECT using the PC cluster can significantly reduce the computation time, whereas its implementation is simple and inexpensive. (author)

  15. A 2D driven 3D vessel segmentation algorithm for 3D digital subtraction angiography data

    International Nuclear Information System (INIS)

    Spiegel, M; Hornegger, J; Redel, T; Struffert, T; Doerfler, A

    2011-01-01

    Cerebrovascular disease is among the leading causes of death in western industrial nations. 3D rotational angiography delivers indispensable information on vessel morphology and pathology. Physicians make use of this to analyze vessel geometry in detail, i.e. vessel diameters, location and size of aneurysms, to come up with a clinical decision. 3D segmentation is a crucial step in this pipeline. Although a lot of different methods are available nowadays, all of them lack a method to validate the results for the individual patient. Therefore, we propose a novel 2D digital subtraction angiography (DSA)-driven 3D vessel segmentation and validation framework. 2D DSA projections are clinically considered as gold standard when it comes to measurements of vessel diameter or the neck size of aneurysms. An ellipsoid vessel model is applied to deliver the initial 3D segmentation. To assess the accuracy of the 3D vessel segmentation, its forward projections are iteratively overlaid with the corresponding 2D DSA projections. Local vessel discrepancies are modeled by a global 2D/3D optimization function to adjust the 3D vessel segmentation toward the 2D vessel contours. Our framework has been evaluated on phantom data as well as on ten patient datasets. Three 2D DSA projections from varying viewing angles have been used for each dataset. The novel 2D driven 3D vessel segmentation approach shows superior results against state-of-the-art segmentations like region growing, i.e. an improvement of 7.2% points in precision and 5.8% points for the Dice coefficient. This method opens up future clinical applications requiring the greatest vessel accuracy, e.g. computational fluid dynamic modeling.

  16. 3D gaze tracking system for NVidia 3D Vision®.

    Science.gov (United States)

    Wibirama, Sunu; Hamamoto, Kazuhiko

    2013-01-01

    Inappropriate parallax setting in stereoscopic content generally causes visual fatigue and visual discomfort. To optimize three dimensional (3D) effects in stereoscopic content by taking into account health issue, understanding how user gazes at 3D direction in virtual space is currently an important research topic. In this paper, we report the study of developing a novel 3D gaze tracking system for Nvidia 3D Vision(®) to be used in desktop stereoscopic display. We suggest an optimized geometric method to accurately measure the position of virtual 3D object. Our experimental result shows that the proposed system achieved better accuracy compared to conventional geometric method by average errors 0.83 cm, 0.87 cm, and 1.06 cm in X, Y, and Z dimensions, respectively.

  17. An MGF-based unified framework to determine the joint statistics of partial sums of ordered i.n.d. random variables

    KAUST Repository

    Nam, Sungsik

    2014-08-01

    The joint statistics of partial sums of ordered random variables (RVs) are often needed for the accurate performance characterization of a wide variety of wireless communication systems. A unified analytical framework to determine the joint statistics of partial sums of ordered independent and identically distributed (i.i.d.) random variables was recently presented. However, the identical distribution assumption may not be valid in several real-world applications. With this motivation in mind, we consider in this paper the more general case in which the random variables are independent but not necessarily identically distributed (i.n.d.). More specifically, we extend the previous analysis and introduce a new more general unified analytical framework to determine the joint statistics of partial sums of ordered i.n.d. RVs. Our mathematical formalism is illustrated with an application on the exact performance analysis of the capture probability of generalized selection combining (GSC)-based RAKE receivers operating over frequency-selective fading channels with a non-uniform power delay profile. © 1991-2012 IEEE.

  18. Simultaneous formation of 3-deoxy-d-threo-hexo-2-ulose and 3-deoxy-d-erythro-hexo-2-ulose during the degradation of d-glucose derived Amadori rearrangement products: Mechanistic considerations.

    Science.gov (United States)

    Kaufmann, Martin; Krüger, Sophie; Mügge, Clemens; Kroh, Lothar W

    2018-03-22

    Analyzing classical model reaction systems of Amadori rearrangement products (ARP) it became apparent that the formation of 3-deoxy-d-threo-hexo-2-ulose (3-deoxygalactosone, 3-DGal) during the degradation of ARPs is highly dependent on pH and the amino acid residue of the respective ARP. Based on a detailed analysis of the NMR chemical shifts of the sugar moieties of different ARPs, it could be derived that the formation of 3-DGal is sensitive to the stability of a co-operative hydrogen bond network which involves HO-C3, the deprotonated carboxyl functionality and the protonated amino nitrogen of the amino acid substituent. Participating in this bond network, HO-C3 is partially protonated which facilitates the elimination of water at C3. Based on that, a new mechanism of 3-deoxyglycosone formation is proposed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. LandSIM3D: modellazione in real time 3D di dati geografici

    Directory of Open Access Journals (Sweden)

    Lambo Srl Lambo Srl

    2009-03-01

    Full Text Available LandSIM3D: realtime 3D modelling of geographic data LandSIM3D allows to model in 3D an existing landscape in a few hours only and geo-referenced offering great landscape analysis and understanding tools. 3D projects can then be inserted into the existing landscape with ease and precision. The project alternatives and impact can then be visualized and studied into their immediate environmental. The complex evolution of the landscape in the future can also be simulated and the landscape model can be manipulated interactively and better shared with colleagues. For that reason, LandSIM3D is different from traditional 3D imagery solutions, normally reserved for computer graphics experts. For more information about LandSIM3D, go to www.landsim3d.com.

  20. Nanometre-scale 3D defects in Cr2AlC thin films.

    Science.gov (United States)

    Chen, Y T; Music, D; Shang, L; Mayer, J; Schneider, J M

    2017-04-20

    MAX-phase Cr 2 AlC containing thin films were synthesized by magnetron sputtering in an industrial system. Nanometre-scale 3D defects are observed near the boundary between regions of Cr 2 AlC and of the disordered solid solution (CrAl) x C y . Shrinkage of the Cr-Cr interplanar distance and elongation of the Cr-Al distance in the vicinity of the defects are detected using transmission electron microscopy. The here observed deformation surrounding the defects was described using density functional theory by comparing the DOS of bulk Cr 2 AlC with the DOS of a strained and unstrained Cr 2 AlC(0001) surface. From the partial density of states analysis, it can be learned that Cr-C bonds are stronger than Cr-Al bonds in bulk Cr 2 AlC. Upon Cr 2 AlC(0001) surface formation, both bonds are weakened. While the Cr-C bonds recover their bulk strength as Cr 2 AlC(0001) is strained, the Cr-Al bonds experience only a partial recovery, still being weaker than their bulk counterparts. Hence, the strain induced bond strengthening in Cr 2 AlC(0001) is larger for Cr d - C p bonds than for Cr d - Al p bonds. The here observed changes in bonding due to the formation of a strained surface are consistent with the experimentally observed elongation of the Cr-Al distance in the vicinity of nm-scale 3D defects in Cr 2 AlC thin films.

  1. 3D-FBK Pixel sensors: recent beam tests results with irradiated devices

    CERN Document Server

    Micelli, A; Sandaker, H; Stugu, B; Barbero, M; Hugging, F; Karagounis, M; Kostyukhin, V; Kruger, H; Tsung, J W; Wermes, N; Capua, M; Fazio, S; Mastroberardino, A; Susinno, G; Gallrapp, C; Di Girolamo, B; Dobos, D; La Rosa, A; Pernegger, H; Roe, S; Slavicek, T; Pospisil, S; Jakobs, K; Kohler, M; Parzefall, U; Darbo, G; Gariano, G; Gemme, C; Rovani, A; Ruscino, E; Butter, C; Bates, R; Oshea, V; Parker, S; Cavalli-Sforza, M; Grinstein, S; Korokolov, I; Pradilla, C; Einsweiler, K; Garcia-Sciveres, M; Borri, M; Da Via, C; Freestone, J; Kolya, S; Lai, C H; Nellist, C; Pater, J; Thompson, R; Watts, S J; Hoeferkamp, M; Seidel, S; Bolle, E; Gjersdal, H; Sjobaek, K N; Stapnes, S; Rohne, O; Su, D; Young, C; Hansson, P; Grenier, P; Hasi, J; Kenney, C; Kocian, M; Jackson, P; Silverstein, D; Davetak, H; DeWilde, B; Tsybychev, D; Dalla Betta, G F; Gabos, P; Povoli, M; Cobal, M; Giordani, M P; Selmi, L; Cristofoli, A; Esseni, D; Palestri, P; Fleta, C; Lozano, M; Pellegrini, G; Boscardin, M; Bagolini, A; Piemonte, C; Ronchin, S; Zorzi, N; Hansen, T E; Hansen, T; Kok, A; Lietaer, N; Kalliopuska, J; Oja, A

    2011-01-01

    The Pixel detector is the innermost part of the ATLAS experiment tracking device at the Large Hadron Collider (LHC), and plays a key role in the reconstruction of the primary and secondary vertices of short-lived particles. To cope with the high level of radiation produced during the collider operation, it is planned to add to the present three layers of silicon pixel sensors which constitute the Pixel Detector, an additional layer (Insertable B-Layer, or IBL) of sensors. 3D silicon sensors are one of the technologies which are under study for the IBL. 3D silicon technology is an innovative combination of very-large-scale integration (VLSI) and Micro-Electro-Mechanical-Systems (MEMS) where electrodes are fabricated inside the silicon bulk instead of being implanted on the wafer surfaces. 3D sensors, with electrodes fully or partially penetrating the silicon substrate, are currently fabricated at different processing facilities in Europe and USA. This paper reports on the 2010 June beam test results for irradi...

  2. Identification of the transition arrays 3d74s-3d74p in Br X and 3d64s-3d64p in Br XI

    International Nuclear Information System (INIS)

    Zeng, X.T.; Jupen, C.; Bengtsson, P.; Engstroem, L.; Westerlind, M.; Martinson, I.

    1991-01-01

    We report a beam-foil study of multiply ionized bromine in the region 400-1300A, performed with 6 and 8 MeV Br ions from a tandem accelerator. At these energies transitions belonging to Fe-like Br X and Mn-like Br XI are expected to be prominent. We have identified 31 lines as 3d 7 4s-3d 7 4p transitions in Br X, from which 16 levels of the previously unknown 3d 7 4s configuration could be established. We have also added 6 new 3d 7 4p levels to the 99 previously known. For Br XI we have classified 9 lines as 3d 6 4s-3d 6 4p combinations. The line identifications have been corroborated by isoelectronic comparisons and theoretical calculations using the superposition-of-configurations technique. (orig.)

  3. Investigation of the C-3-epi-25(OH)D3 of 25-hydroxyvitamin D3 in urban schoolchildren.

    Science.gov (United States)

    Berger, Samantha E; Van Rompay, Maria I; Gordon, Catherine M; Goodman, Elizabeth; Eliasziw, Misha; Holick, Michael F; Sacheck, Jennifer M

    2018-03-01

    The physiological relevance C-3 epimer of 25-hydroxyvitamin D (3-epi-25(OH)D) is not well understood among youth. The objective of this study was to assess whether demographic/physiologic characteristics were associated with 3-epi-25(OH)D 3 concentrations in youth. Associations between 3-epi-25(OH)D 3 and demographics and between 3-epi-25(OH)D 3 , total 25-hydroxyvitamin (25(OH)D) (25(OH)D 2 + 25(OH)D 3 ), total cholesterol, high-density lipoprotein, low-density lipoprotein, and triglycerides were examined in racially/ethnically diverse schoolchildren (n = 682; age, 8-15 years) at Boston-area urban schools. Approximately 50% of participants had detectable 3-epi-25(OH)D 3 (range 0.95-3.95 ng/mL). The percentage of 3-epi-25(OH)D 3 of total 25(OH)D ranged from 2.5% to 17.0% (median 5.5%). Males were 38% more likely than females to have detectable 3-epi-25(OH)D 3 concentrations. Both Asian and black race/ethnicity were associated with lower odds of having detectable 3-epi-25(OH)D 3 compared with non-Hispanic white children (Asian vs. white, odds ratio (OR) 0.28, 95% confidence interval (CI) 0.14-0.53; black vs. white, OR 0.38, 95%CI 0.23-0.63, p 30 ng/mL) 25(OH)D concentration was associated with higher odds of having detectable 3-epi-25(OH)D 3 than having an inadequate (<20 ng/mL) concentration (OR 4.78, 95%CI 3.23-6.94 or OR 14.10, 95%CI 7.10-28.0, respectively). There was no association between 3-epi-25(OH)D 3 and blood lipids. However, when considering 3-epi-25(OH)D 3 as a percentage of total 25(OH)D, total cholesterol was lower in children with percent 3-epi-25(OH)D 3 above the median (mean difference -7.1 mg/dL, p = 0.01). In conclusion, among schoolchildren, sex, race/ethnicity, and total serum 25(OH)D concentration is differentially associated with 3-epi-25(OH)D. The physiological relevance of 3-epi-25(OH)D 3 may be related to the 3-epi-25(OH)D 3 as a percentage of total 25(OH)D and should be considered in future investigations.

  4. Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla.

    Science.gov (United States)

    Fallah, Faezeh; Machann, Jürgen; Martirosian, Petros; Bamberg, Fabian; Schick, Fritz; Yang, Bin

    2017-04-01

    To evaluate and compare conventional T1-weighted 2D turbo spin echo (TSE), T1-weighted 3D volumetric interpolated breath-hold examination (VIBE), and two-point 3D Dixon-VIBE sequences for automatic segmentation of visceral adipose tissue (VAT) volume at 3 Tesla by measuring and compensating for errors arising from intensity nonuniformity (INU) and partial volume effects (PVE). The body trunks of 28 volunteers with body mass index values ranging from 18 to 41.2 kg/m 2 (30.02 ± 6.63 kg/m 2 ) were scanned at 3 Tesla using three imaging techniques. Automatic methods were applied to reduce INU and PVE and to segment VAT. The automatically segmented VAT volumes obtained from all acquisitions were then statistically and objectively evaluated against the manually segmented (reference) VAT volumes. Comparing the reference volumes with the VAT volumes automatically segmented over the uncorrected images showed that INU led to an average relative volume difference of -59.22 ± 11.59, 2.21 ± 47.04, and -43.05 ± 5.01 % for the TSE, VIBE, and Dixon images, respectively, while PVE led to average differences of -34.85 ± 19.85, -15.13 ± 11.04, and -33.79 ± 20.38 %. After signal correction, differences of -2.72 ± 6.60, 34.02 ± 36.99, and -2.23 ± 7.58 % were obtained between the reference and the automatically segmented volumes. A paired-sample two-tailed t test revealed no significant difference between the reference and automatically segmented VAT volumes of the corrected TSE (p = 0.614) and Dixon (p = 0.969) images, but showed a significant VAT overestimation using the corrected VIBE images. Under similar imaging conditions and spatial resolution, automatically segmented VAT volumes obtained from the corrected TSE and Dixon images agreed with each other and with the reference volumes. These results demonstrate the efficacy of the signal correction methods and the similar accuracy of TSE and Dixon imaging for automatic volumetry of VAT at 3 Tesla.

  5. "3D fusion" echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.

    Science.gov (United States)

    Augustine, Daniel; Yaqub, Mohammad; Szmigielski, Cezary; Lima, Eduardo; Petersen, Steffen E; Becher, Harald; Noble, J Alison; Leeson, Paul

    2015-02-01

    Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography. © 2014, Wiley Periodicals, Inc.

  6. Measurement of partial widths and search for direct cp violation in D0 meson decays to K-K+ and π-π+

    International Nuclear Information System (INIS)

    Acosta, D.; The CDF Collaboration

    2005-01-01

    We present a measurement of relative partial widths and decay rate CP asymmetries in K - K + and π - π + decays of D 0 mesons produced in p(bar p) collisions at √s = 1.96TeV. We use a sample of 2 x 10 5 D* + → D 0 π + (and charge conjugate) decays with the D 0 decaying to K - π + , K - K + , and π - π + , corresponding to 123 pb -1 of data collected by the Collider Detector at Fermilab II experiment at the Fermilab Tevatron collider. No significant direct CP violation is observed. We measure Λ(D 0 → K - K + )/Λ(D 0 → K - π + ) = 0.0992 ± 0.0011 ± 0.0012, Λ(D 0 → π - π + )/Λ(D 0 → K - π + ) = 0.03594 ± 0.00054 ± 0.00040, A CP (K - K + ) = (2.0 ± 1.2 ± 0.6)%, and A CP (π - π + ) = (1.0 ± 1.3 ± 0.6) %, where, in all cases, the first uncertainty is statistical and the second is systematic

  7. In vivo production of recombinant proteins using occluded recombinant AcMNPV-derived baculovirus vectors.

    Science.gov (United States)

    Guijarro-Pardo, Eva; Gómez-Sebastián, Silvia; Escribano, José M

    2017-12-01

    Trichoplusia ni insect larvae infected with vectors derived from the Autographa californica multiple nucleopolyhedrovirus (AcMNPV), are an excellent alternative to insect cells cultured in conventional bioreactors to produce recombinant proteins because productivity and cost-efficiency reasons. However, there is still a lot of work to do to reduce the manual procedures commonly required in this production platform that limit its scalability. To increase the scalability of this platform technology, a current bottleneck to be circumvented in the future is the need of injection for the inoculation of larvae with polyhedrin negative baculovirus vectors (Polh-) because of the lack of oral infectivity of these viruses, which are commonly used for production in insect cell cultures. In this work we have developed a straightforward alternative to obtain orally infective vectors derived from AcMNPV and expressing recombinant proteins that can be administered to the insect larvae (Trichoplusia ni) by feeding, formulated in the insect diet. The approach developed was based on the use of a recombinant polyhedrin protein expressed by a recombinant vector (Polh+), able to co-occlude any recombinant Polh- baculovirus vector expressing a recombinant protein. A second alternative was developed by the generation of a dual vector co-expressing the recombinant polyhedrin protein and the foreign gene of interest to obtain the occluded viruses. Additionally, by the incorporation of a reporter gene into the helper Polh+ vector, it was possible the follow-up visualization of the co-occluded viruses infection in insect larvae and will help to homogenize infection conditions. By using these methodologies, the production of recombinant proteins in per os infected larvae, without manual infection procedures, was very similar in yield to that obtained by manual injection of recombinant Polh- AcMNPV-based vectors expressing the same proteins. However, further analyses will be required for a

  8. iCAVE: an open source tool for visualizing biomolecular networks in 3D, stereoscopic 3D and immersive 3D.

    Science.gov (United States)

    Liluashvili, Vaja; Kalayci, Selim; Fluder, Eugene; Wilson, Manda; Gabow, Aaron; Gümüs, Zeynep H

    2017-08-01

    Visualizations of biomolecular networks assist in systems-level data exploration in many cellular processes. Data generated from high-throughput experiments increasingly inform these networks, yet current tools do not adequately scale with concomitant increase in their size and complexity. We present an open source software platform, interactome-CAVE (iCAVE), for visualizing large and complex biomolecular interaction networks in 3D. Users can explore networks (i) in 3D using a desktop, (ii) in stereoscopic 3D using 3D-vision glasses and a desktop, or (iii) in immersive 3D within a CAVE environment. iCAVE introduces 3D extensions of known 2D network layout, clustering, and edge-bundling algorithms, as well as new 3D network layout algorithms. Furthermore, users can simultaneously query several built-in databases within iCAVE for network generation or visualize their own networks (e.g., disease, drug, protein, metabolite). iCAVE has modular structure that allows rapid development by addition of algorithms, datasets, or features without affecting other parts of the code. Overall, iCAVE is the first freely available open source tool that enables 3D (optionally stereoscopic or immersive) visualizations of complex, dense, or multi-layered biomolecular networks. While primarily designed for researchers utilizing biomolecular networks, iCAVE can assist researchers in any field. © The Authors 2017. Published by Oxford University Press.

  9. 3D accelerator magnet calculations using MAGNUS-3D

    International Nuclear Information System (INIS)

    Pissanetzky, S.; Miao, Y.

    1989-01-01

    The steady trend towards increased magnetic and geometric complexity in the design of accelerator magnets has caused a need for reliable 3D computer models and a better understanding of the behavior of magnetic system in three dimensions. The capabilities of the MAGNUS-3D family of programs are ideally suited to solve this class of problems and provide insight into 3D effects. MAGNUS-3D can solve any problem of magnetostatics involving permanent magnets, nonlinear ferromagnetic materials and electric conductors. MAGNUS-3D uses the finite element method and the two-scalar-potentials formulation of Maxwell's equations to obtain the solution, which can then be used interactively to obtain tables of field components at specific points or lines, plots of field lines, function graphs representing a field component plotted against a coordinate along any line in space (such as the beam line), and views of the conductors, the mesh and the magnetic bodies. The magnetic quantities that can be calculated include the force or torque on conductors or magnetic parts, the energy, the flux through a specified surface, line integrals of any field component along any line in space, and the average field or potential harmonic coefficients. We describe the programs with emphasis placed on their use for accelerator magnet design, and present an advanced example of actual calculations. (orig.)

  10. Turbulent Dynamics of Partially-Ionized Fluids in 2D

    Science.gov (United States)

    Benavides, S.; Flierl, G.

    2017-12-01

    Ionization occurs in the upper atmospheres of Hot Jupiters, as well asthe interiors of Gas Giants, leading to Magnetohydrodynamic (MHD) effectswhich can significantly alter the flow. The interactions of these MHDregions with the non-ionized atmosphere will occur in transitionregions where only a fraction of the fluid is ionized. We areexploring the dynamics of Partially-Ionized MHD (PIMHD) using a twofluid model - one neutral and one ionized and subject to MHD -coupled by a collision, or Joule heating, term proportional to thedifference in velocities. By varying both the ionization fraction aswell as the collision frequency (coupling), we examine the parameterspace of 2D PIMHD turbulence in hopes of better understanding itscharacteristics in certain, possibly realistic, regimes. We payparticular attention to the Joule heating term and its role indissipation and energy exchange between the two species. Thisknowledge will serve as the basis to further studies in which we lookat, in a more realistic setting, the PIMHD dynamics in Gas Giant orHot Jupiter atmospheres.

  11. Recording stereoscopic 3D neurosurgery with a head-mounted 3D camera system.

    Science.gov (United States)

    Lee, Brian; Chen, Brian R; Chen, Beverly B; Lu, James Y; Giannotta, Steven L

    2015-06-01

    Stereoscopic three-dimensional (3D) imaging can present more information to the viewer and further enhance the learning experience over traditional two-dimensional (2D) video. Most 3D surgical videos are recorded from the operating microscope and only feature the crux, or the most important part of the surgery, leaving out other crucial parts of surgery including the opening, approach, and closing of the surgical site. In addition, many other surgeries including complex spine, trauma, and intensive care unit procedures are also rarely recorded. We describe and share our experience with a commercially available head-mounted stereoscopic 3D camera system to obtain stereoscopic 3D recordings of these seldom recorded aspects of neurosurgery. The strengths and limitations of using the GoPro(®) 3D system as a head-mounted stereoscopic 3D camera system in the operating room are reviewed in detail. Over the past several years, we have recorded in stereoscopic 3D over 50 cranial and spinal surgeries and created a library for education purposes. We have found the head-mounted stereoscopic 3D camera system to be a valuable asset to supplement 3D footage from a 3D microscope. We expect that these comprehensive 3D surgical videos will become an important facet of resident education and ultimately lead to improved patient care.

  12. Probabilistic Characterization of Partial Volume Effects in Imaging of Rectangular Objects

    Energy Technology Data Exchange (ETDEWEB)

    Bulaevskaya, V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-05-06

    In imaging, a partial volume effect refers to the problem that arises when the system resolution is low relative to the size of the object being imaged [1, 2]. In this setting, it is likely that most voxels occupied by the object are only partially covered, and that the fraction covered in each voxel is low. This makes the problem of object detection and image segmentation very difficult because the algorithms designed for these purposes rely on pixel summary statistics. If the area covered by the object is very low in relatively many of the total number of the voxels the object occupies, these summary statistics may not reach the thresholds required to detect this object. It is thus important to understand the extent of partial volume effect for a given object size and resolution. This technical report focuses on rectangular objects and derives the probability distributions for three quantities for such objects: 1) the number of fully covered voxels, 2) the number of partially covered voxels, and 3) the fractions of the total volume covered in the partially covered voxels. The derivations are first shown for 2-D settings and are then extended to 3-D settings.

  13. Ileal Varices Treated with Balloon-Occluded Retrograde Transvenous Obliteration.

    Science.gov (United States)

    Sato, Takahiro; Yamazaki, Katsu; Toyota, Jouji; Karino, Yoshiyasu; Ohmura, Takumi; Akaike, Jun

    2009-04-01

    A 55-year-old man with hepatitis B virus antigen-positive liver cirrhosis was admitted to our hospital with anal bleeding. Colonoscopy revealed blood retention in the entire colon, but no bleeding lesion was found. Computed tomography images showed that vessels in the ileum were connected to the right testicular vein, and we suspected ileal varices to be the most probable cause of bleeding. We immediately performed double balloon enteroscopy, but failed to find any site of bleeding owing to the difficulty of fiberscope insertion with sever adhesion. Using a balloon catheter during retrograde transvenous venography, we found ileal varices communicating with the right testicular vein (efferent vein) with the superior mesenteric vein branch as the afferent vein of these varices. We performed balloon occluded retrograde transvenous obliteration by way of the efferent vein of the varices and have detected no further bleeding in this patient one year after treatment.

  14. Cholecystokinin (CCK) functional cholescintigraphic findings in patients with a partial cystic duct obstruction - the cystic duct syndrome (CDS)

    International Nuclear Information System (INIS)

    Fink-Bennett, D.; DeRidder, P.; Kolozsi, W.; Gordon, R.

    1984-01-01

    Fourteen patients (pts.) with a CDS underwent CCK functional cholescintigraphy (FC). All pts. presented with persistent post-prandial right upper quadrant pain and biliary colic. None had an abnormal OCG, gallbladder (GB) ultrasound exam or upper G.I. series. All had macro- or microscopically abnormal cystic ducts (5 fibrotic, 7 elongated and narrow, 2 kinked) with (12) or without (2) concomitant chronic cholecystitis. Each pt. (NPO after 12 A.M.) received 5 mCi of technetium (TC)-99m Hepatolite. When the GB max. filled, .02 ug/kg CCK was administered (3 min.) I.V. Background corrected GBEFs were determined q.5 min. x 4 by ratioing the pre-CCK GB cts. minus post-CCK GB cts. to pre-CCK GB cts. GB EFRs were: 3 (12%), 2 (17%), and 1 each 0%, 1.3%, 3%, 4%, 6%, 11%, 14%, 18.5% and 22%. No pt. with a partially occluded cystic duct with or without concomitant chronic cholecystitis had an ejection fraction that exceeded 22%. In an appropriate clinical setting, a low ejection fraction response to CCK should alert the physician to the presence of either chronic acalculous cholecystitis, CDS, or the combination of both

  15. Growth kinetics of tetragonal and monoclinic ZrO2 crystallites in 3 mol% yttria partially stabilized ZrO2 (3Y-PSZ) precursor powder

    International Nuclear Information System (INIS)

    Kuo, Chih-Wei; Lee, Kuen-Chan; Yen, Feng-Lin; Shen, Yun-Hwei; Lee, Huey-Er; Wen, Shaw-Bing; Wang, Moo-Chin; Stack, Margaret Mary

    2014-01-01

    Highlights: • The crystalline structures were composed of tetragonal and monoclinic ZrO 2 . • Growth kinetics of t-ZrO 2 in the 3Y-PSZ precursor powder is described as: D te 2 =(4.57±0.55)t 0.12±0.02 exp(-((24.79±0.38)×10 3 )/(RT) ). • Growth kinetics of m-ZrO 2 in the 3Y-PSZ precursor powder is described as: D m 2 =(4.40±1.63)t 0.17±0.08 exp(-((66.47±3.97)×10 3 )/(RT) ). - Abstract: The growth kinetics of tetragonal and monoclinic ZrO 2 crystallites in 3 mol% yttria partially stabilized ZrO 2 (3Y-PSZ) precursor powder has been investigated using X-ray diffraction (XRD), Brunauer–Emmett–Teller (BET) specific surface area analysis, transmission electron microscopy (TEM) and high resolution TEM (HRTEM). After calcination of the 3Y-PSZ precursor powder between 773 and 1073 K for 2 h, the crystalline structures were composed of tetragonal and monoclinic ZrO 2 as the primary and secondary phases, respectively. When the 3Y-PSZ precursor powder was calcined at 773 K for 2 h, the BET specific surface area was 97.13 m 2 /g, which is equivalent to a particle size of 10.30 nm. The crystallite sizes determined via XRD and BET agreed well, indicating that the powder was virtually non-agglomerated. The growth kinetics of tetragonal and monoclinic ZrO 2 crystallite isothermal growth in the 3Y-PSZ precursor powder are described by: D te 2 =(4.57±0.55)t 0.12±0.02 exp(-((24.79±0.38)×10 3 )/(RT) ) and D m 2 =(4.40±1.63)t 0.17±0.08 exp(-((66.47±3.97)×10 3 )/(RT) ), respectively, for 773K≤T≤1073K. D te and D m denote the crystallite size of tetragonal and monoclinic ZrO 2 at time t and temperature T, respectively

  16. Dielectric Properties of 3D Printed Polylactic Acid

    Directory of Open Access Journals (Sweden)

    Claudius Dichtl

    2017-01-01

    Full Text Available 3D printers constitute a fast-growing worldwide market. These printers are often employed in research and development fields related to engineering or architecture, especially for structural components or rapid prototyping. Recently, there is enormous progress in available materials for enhanced printing systems that allow additive manufacturing of complex functional products, like batteries or electronics. The polymer polylactic acid (PLA plays an important role in fused filament fabrication, a technique used for commercially available low-budget 3D printers. This printing technology is an economical tool for the development of functional components or cases for electronics, for example, for lab purposes. Here we investigate if the material properties of “as-printed” PLA, which was fabricated by a commercially available 3D printer, are suitable to be used in electrical measurement setups or even as a functional material itself in electronic devices. For this reason, we conduct differential scanning calorimetry measurements and a thorough temperature and frequency-dependent analysis of its dielectric properties. These results are compared to partially crystalline and completely amorphous PLA, indicating that the dielectric properties of “as-printed” PLA are similar to the latter. Finally, we demonstrate that the conductivity of PLA can be enhanced by mixing it with the ionic liquid “trihexyl tetradecyl phosphonium decanoate.” This provides a route to tailor PLA for complex functional products produced by an economical fused filament fabrication.

  17. Temperature dependence of the partially localized state in a 2D molecular nanoporous network

    Energy Technology Data Exchange (ETDEWEB)

    Piquero-Zulaica, Ignacio, E-mail: ipiquerozulaica@gmail.com [Centro de Física de Materiales (CSIC/UPV-EHU)—Materials Physics Center, Manuel Lardizabal 5, 20018 San Sebastián (Spain); Nowakowska, Sylwia [Department of Physics, University of Basel, Klingelbergstrasse 82, 4056 Basel (Switzerland); Ortega, J. Enrique [Centro de Física de Materiales (CSIC/UPV-EHU)—Materials Physics Center, Manuel Lardizabal 5, 20018 San Sebastián (Spain); Donostia International Physics Center (DIPC), Manuel Lardizabal 4, 20018 San Sebastián (Spain); Departamento Física Aplicada I, Universidad del País Vasco, 20018 San Sebastián (Spain); Stöhr, Meike [Zernike Institute for Advanced Materials, University of Groningen, Nijenborgh 4, 9747 AG Groningen (Netherlands); Gade, Lutz H. [Anorganisch-Chemisches Institut, Universität Heidelberg, Im Neuenheimer Feld 270, 69120 Heidelberg (Germany); Jung, Thomas A. [Laboratory for Micro- and Nanotechnology, Paul Scherrer Institute, 5232 Villigen (Switzerland); Lobo-Checa, Jorge, E-mail: jorge.lobo@csic.es [Instituto de Ciencia de Materiales de Aragón (ICMA), CSIC-Universidad de Zaragoza, E-50009 Zaragoza (Spain); Departamento de Física de la Materia Condensada, Universidad de Zaragoza, E-50009 Zaragoza (Spain)

    2017-01-01

    Highlights: • A state of a 2D porous network is demonstrated to originate from the Shockley state. • The temperature evolution of both states is followed by means of ARPES. • Identical energy shifts are observed for both states, proving their common origin. - Abstract: Two-dimensional organic and metal-organic nanoporous networks can scatter surface electrons, leading to their partial localization. Such quantum states are related to intrinsic surface states of the substrate material. We further corroborate this relation by studying the thermally induced energy shifts of the electronic band stemming from coupled quantum states hosted in a metal-organic array formed by a perylene derivative on Cu(111). We observe by angle-resolved photoemission spectroscopy (ARPES), that both, the Shockley and the partially localized states, shift by the same amount to higher binding energies upon decreasing the sample temperature, providing evidence of their common origin. Our experimental approach and results further support the use of surface states for modelling these systems, which are expected to provide new insight into the physics concerning partially confined electronic states: scattering processes, potential barrier strengths, excited state lifetimes or the influence of guest molecules.

  18. Application of Balloon-Occluded Retrograde Transvenous Obliteration to Gastric Varices Complicating Refractory Ascites

    International Nuclear Information System (INIS)

    Fukuda, Tetsuya; Hirota, Shozo; Matsumoto, Shinichi; Sugimoto, Koji; Fujii, Masahiko; Tsurusaki, Masakatsu; Izaki, Kenta; Sugimura, Kazuro

    2004-01-01

    We report two cases of gastric varices complicated by massive ascites that disappeared after balloon-occluded retrograde transvenous obliteration (B-RTO). The first patient had progressive gastric varices that continued to enlarge even after three episodes of esophagogastric variceal bleeding, and the second patient was admitted to our hospital because of the bleeding from gastric varices. After B-RTO procedures in both patients, significant improvement of the ascites, hepatic function reserve, and hypoalbuminemia was observed. Although further experience is needed, our experience points to the likelihood of the amelioration of ascites after B-RTO

  19. geomIO: A tool for geodynamicists to turn 2D cross-sections into 3D geometries

    Science.gov (United States)

    Baumann, Tobias; Bauville, Arthur

    2016-04-01

    In numerical deformation models, material properties are usually defined on elements (e.g., in body-fitted finite elements), or on a set of Lagrangian markers (Eulerian, ALE or mesh-free methods). In any case, geometrical constraints are needed to assign different material properties to the model domain. Whereas simple geometries such as spheres, layers or cuboids can easily be programmed, it quickly gets complex and time-consuming to create more complicated geometries for numerical model setups, especially in three dimensions. geomIO (geometry I/O, http://geomio.bitbucket.org/) is a MATLAB-based library that has two main functionalities. First, it can be used to create 3D volumes based on series of 2D vector drawings similar to a CAD program; and second, it uses these 3D volumes to assign material properties to the numerical model domain. The drawings can conveniently be created using the open-source vector graphics software Inkscape. Adobe Illustrator is also partially supported. The drawings represent a series of cross-sections in the 3D model domain, for example, cross-sectional interpretations of seismic tomography. geomIO is then used to read the drawings and to create 3D volumes by interpolating between the cross-sections. In the second part, the volumes are used to assign material phases to markers inside the volumes. Multiple volumes can be created at the same time and, depending on the order of assignment, unions or intersections can be built to assign additional material phases. geomIO also offers the possibility to create 3D temperature structures for geodynamic models based on depth dependent parameterisations, for example the half space cooling model. In particular, this can be applied to geometries of subducting slabs of arbitrary shape. Yet, geomIO is held very general, and can be used for a variety of applications. We present examples of setup generation from pictures of micro-scale tectonics and lithospheric scale setups of 3D present-day model

  20. 2D-Driven 3D Object Detection in RGB-D Images

    KAUST Repository

    Lahoud, Jean

    2017-12-25

    In this paper, we present a technique that places 3D bounding boxes around objects in an RGB-D scene. Our approach makes best use of the 2D information to quickly reduce the search space in 3D, benefiting from state-of-the-art 2D object detection techniques. We then use the 3D information to orient, place, and score bounding boxes around objects. We independently estimate the orientation for every object, using previous techniques that utilize normal information. Object locations and sizes in 3D are learned using a multilayer perceptron (MLP). In the final step, we refine our detections based on object class relations within a scene. When compared to state-of-the-art detection methods that operate almost entirely in the sparse 3D domain, extensive experiments on the well-known SUN RGB-D dataset [29] show that our proposed method is much faster (4.1s per image) in detecting 3D objects in RGB-D images and performs better (3 mAP higher) than the state-of-the-art method that is 4.7 times slower and comparably to the method that is two orders of magnitude slower. This work hints at the idea that 2D-driven object detection in 3D should be further explored, especially in cases where the 3D input is sparse.

  1. Preparation and luminescence properties of Eu2+-doped CaSi2O2-dN2+2/3d phosphors

    International Nuclear Information System (INIS)

    Gu Yunxin; Zhang Qinghong; Wang Hongzhi; Li Yaogang

    2009-01-01

    Eu 2+ -doped CaSi 2 O 2-d N 2+2/3d phosphors for white LED lamps were prepared by solid-state reaction, and the effects of heat-treatment conditions and the overall composition of host lattice on the optical properties have been discussed. Eu 2+ -doped CaSi 2 O 2-d N 2+2/3d displayed a single broad emission band peak at 540 nm, which could be assigned to the allowed transition of Eu 2+ from the lowest crystal field component of 4f 6 5d to 4f 7 ground-state level. The excitation band of samples, extending from UV to blue, is extremely wide, so the phosphors are suitable for white LED lamps in combination with a UV or blue LED dies. The highest PL intensity is found for the sample sintered at 1400 0 C. Moreover, the emission intensity decreases when N partially replaces O. A red shift of emission wavelength did not occur with increasing of the N content.

  2. E3D, 3-D Elastic Seismic Wave Propagation Code

    International Nuclear Information System (INIS)

    Larsen, S.; Harris, D.; Schultz, C.; Maddix, D.; Bakowsky, T.; Bent, L.

    2004-01-01

    1 - Description of program or function: E3D is capable of simulating seismic wave propagation in a 3D heterogeneous earth. Seismic waves are initiated by earthquake, explosive, and/or other sources. These waves propagate through a 3D geologic model, and are simulated as synthetic seismograms or other graphical output. 2 - Methods: The software simulates wave propagation by solving the elasto-dynamic formulation of the full wave equation on a staggered grid. The solution scheme is 4-order accurate in space, 2-order accurate in time

  3. Comparison of Coil Embolization and Sclerotherapy of Collateral Veins during Balloon Occluded Retrograde Transvenous Obliteration: Its Long Term Effect for Gastric Varix Treatment

    International Nuclear Information System (INIS)

    An, Eun Jung; Kim, Young Hwan; Kim, Seee Hyung

    2011-01-01

    We compared the long term effect gastric varix treatment between coil embolization and sclerotherapy of collateral veins during balloon occluded retrograde transvenous obliteration (BRTO). Between February 2004 and November 2008 48 patients with gastric varix bleeding successfully treated with BRTO 23 underwent embolization of collateral veins during BRTO were enrolled in this study. In patients, collateral veins were embolized with the use of microcoil (group 1). Agent (5% ethanolamine oleate + lipiodol) was used in the remaining 7 patients (Group 2). Recurrence and rebleeding of gastric varix were evaluated by endoscopy or CT. Gastric varix recurred in 4 patients (17.4%) and rebleeding occurred in 2 (8.7%). Recurrence (57.1%, p 0.001) and rebleeding (28.6%, p = 0.029) of gastric occurred in group 2. CT finding within 6 months in partial or complete thrombosis without lipiodol uptake in gastric varix, gastric varix recurred on follow up CT. Coil embolization of collateral veins during BRTO may promote complete obliteration of gastric varix, provide lower recurrence and rebleeding rates of gastric sclerosing agent on long term follow-up.

  4. Drosophila Longevity Assurance Conferred by Reduced Insulin Receptor Substrate Chico Partially Requires d4eBP.

    Directory of Open Access Journals (Sweden)

    Hua Bai

    Full Text Available Mutations of the insulin/IGF signaling (IIS pathway extend Drosophila lifespan. Based on genetic epistasis analyses, this longevity assurance is attributed to downstream effects of the FOXO transcription factor. However, as reported FOXO accounts for only a portion of the observed longevity benefit, suggesting there are additional outputs of IIS to mediate aging. One candidate is target of rapamycin complex 1 (TORC1. Reduced TORC1 activity is reported to slow aging, whereas reduced IIS is reported to repress TORC1 activity. The eukaryotic translation initiation factor 4E binding protein (4E-BP is repressed by TORC1, and activated 4E-BP is reported to increase Drosophila lifespan. Here we use genetic epistasis analyses to test whether longevity assurance mutants of chico, the Drosophila insulin receptor substrate homolog, require Drosophila d4eBP to slow aging. In chico heterozygotes, which are robustly long-lived, d4eBP is required but not sufficient to slow aging. Remarkably, d4eBP is not required or sufficient for chico homozygotes to extend longevity. Likewise, chico heterozygote females partially require d4eBP to preserve age-dependent locomotion, and both chico genotypes require d4eBP to improve stress-resistance. Reproduction and most measures of growth affected by either chico genotype are always independent of d4eBP. In females, chico heterozygotes paradoxically produce more rather than less phosphorylated 4E-BP (p4E-BP. Altered IRS function within the IIS pathway of Drosophila appears to have partial, conditional capacity to regulate aging through an unconventional interaction with 4E-BP.

  5. Aspirex Thrombectomy in Occluded Dialysis Access: A Retrospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Dyer, Jules, E-mail: Jules.Dyer@nhs.net [New Cross Hospital, Department of Radiology (United Kingdom); Rosa, Joao [University Hospitals Bristol NHS Foundation Trust, ST1 Radiology (United Kingdom); Chachlani, Menka [University of Birmingham (United Kingdom); Nicholas, Johann [New Cross Hospital, Department of Radiology (United Kingdom)

    2016-10-15

    PurposeThis study is the first to present the outcomes of the Straub Aspirex device for the salvage of occluded renal dialysis access fistulae.Materials and MethodsThis is a retrospective study, using data from the Renal Unit and Radiology Department database. It included all the patients between 2010 and 2014 who underwent percutaneous mechanical thrombectomy (PMT) treated by JD. Aspirex is an over-the-wire, 6–10 French catheter within which is a rapidly rotating helix which draws thrombus into a window near the tip which it then macerates and removes. Access survival was assessed using the Kaplan–Meier method, and multi-variant analysis was performed using the Cox proportional hazards model. Significance was considered if p < 0.05.ResultsA total of 27 procedures were performed for 19 patients. 13 had autologous arterio-venous fistulae, and 14 had synthetic (PTFE) arterio-venous grafts. 15 were males, 4 females. 100 % of the patients successfully had a channel of thrombus removed. This resulted in an 81.5 % initial clinical success, with primary patency rates of 53.6, 44.3 and 33 % by days 30, 90 and 480, respectively, without significant difference of any analysed covariates. No major complication (pulmonary embolus, paradoxical cerebral infarction, limb ischaemia or significant haemorrhage) occurred.ConclusionAspirex has rates of patency and complication similar to other PMT devices. No covariant studied affected outcome.

  6. Innovations in 3D printing: a 3D overview from optics to organs.

    Science.gov (United States)

    Schubert, Carl; van Langeveld, Mark C; Donoso, Larry A

    2014-02-01

    3D printing is a method of manufacturing in which materials, such as plastic or metal, are deposited onto one another in layers to produce a three dimensional object, such as a pair of eye glasses or other 3D objects. This process contrasts with traditional ink-based printers which produce a two dimensional object (ink on paper). To date, 3D printing has primarily been used in engineering to create engineering prototypes. However, recent advances in printing materials have now enabled 3D printers to make objects that are comparable with traditionally manufactured items. In contrast with conventional printers, 3D printing has the potential to enable mass customisation of goods on a large scale and has relevance in medicine including ophthalmology. 3D printing has already been proved viable in several medical applications including the manufacture of eyeglasses, custom prosthetic devices and dental implants. In this review, we discuss the potential for 3D printing to revolutionise manufacturing in the same way as the printing press revolutionised conventional printing. The applications and limitations of 3D printing are discussed; the production process is demonstrated by producing a set of eyeglass frames from 3D blueprints.

  7. Anti-D reagents should be chosen accordingly to the prevalence of D variants in the obstetric population.

    Science.gov (United States)

    Lukacevic Krstic, Jelena; Dajak, Slavica; Bingulac-Popovic, Jasna; Dogic, Vesna; Mratinovic-Mikulandra, Jela

    2018-03-01

    Resolving ambiguous results of D antigen typing is crucial for appropriate and rational administration of anti-D immunoprophylaxis and transfusion practice in obstetric population. The aim of the study was to establish selection criteria of anti-D reagents for our population. A total of 12 689 samples from primiparous women in Split-Dalmatia County, Croatia, were typed for RhD antigen during the period of 5 years. Ambiguous results were submitted to additional serologic investigation and genotyping. RHD genotyping was performed by commercial genotyping kits (Ready Gene weak D ® and Ready gene CDE, Inno-Train, Kronberg, Germany). Relative frequencies and accompanying 95% confidence intervals were used to estimate the prevalence of variants. The prevalence of D variants was 0.42% (95% CI 0.31; 0.53). The most common partial D variant was D Va (RHD*05.05), with the prevalence of 0.08% (95% CI 0.03; 0.13). All weak D variants were weak D types 1, 2 and 3 (RHD*weak D type 1, RHD*weak D type 2, RHD*weak D type 3). Weak D samples were distinguishable from partial D in routine typing due to the difference in reactivity of partial D samples with clones D7B8 and RUM-1. Cell line RUM-1 gives weak or negative reactions with partial DVa category. The most common partial D variant in our population is DVa. It is recommended to use cell lines which do not strongly agglutinate DVa variant in routine RhD typing. The appropriate choice of reagents will enable the serology methods to recognize the cases in which RHD genotyping is required. © 2017 Wiley Periodicals, Inc.

  8. Impact of Volumetric Modulated Arc Therapy Technique on Treatment With Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Qiu Jianjian; Chang Zheng; Wu, Q. Jackie; Yoo, Sua; Horton, Janet; Yin Fangfang

    2010-01-01

    Purpose: To investigate the technical feasibility of volumetric modulated arc therapy (V-MAT) in the delivery of partial breast irradiation (PBI). Methods and Materials: V-MAT and the standard, three-dimensional conformal radiotherapy (3D-CRT), were compared retrospectively in 8 patients previously treated with PBI. These patients' plans were replanned with a single partial arc using V-MAT that included partial blocking to minimize normal tissue dose. Dosimetric parameters were calculated to evaluate plan quality. Quality assurance studies included verifying both the point and the multiple planar doses. Total monitor units and delivery time were also evaluated, and collision clearance was analyzed. Results: Volumes of ipsilateral lung irradiated to 10 Gy (V10) and 20 Gy (V20) by V-MAT were significantly less than those of 3D-CRT (p = 0.03 for V10 and p = 0.025 for V20). The volume of ipsilateral breast irradiated to 5 Gy was significantly less by using V-MAT than with 3D-CRT (p = 0.02), with a ratio of integrated dose of <1.00. The total mean monitor units (489 ± 38) for V-MAT were significantly less than those for 3D-CRT (634 ± 123) (p = 0.017), with a 23% reduction. The average machine delivery time was 1.21 ± 0.10 min for the V-MAT plans and 6.28 ± 1.40 min for the 3D-CRT plans, resulting in a reduction factor of 80.1%. The conformity indexes were 1.3 in the V-MAT plans and 1.5 in the 3D-CRT plans (p = 0.102). Conclusions: V-MAT technology is feasible for PBI patients. Compared to a conventional 3D-CRT technique, it is more efficient, offers equivalent or better dose conformity, delivers lower doses to the ipsilateral lung and breast, and may potentially reduce intrafractional motion.

  9. Through-flow analysis of steam turbines operating under partial admission

    International Nuclear Information System (INIS)

    Delabriere, H.; Werthe, J.M.

    1993-05-01

    In order to produce electric energy with improved efficiency, Electricite de France has to check the performances of equipment proposed by manufacturers. In the specific field of steam turbines, one of the main tools of analysis is the quasi 3D through flow computer code CAPTUR, which enables the calculation of all the aerothermodynamic parameters in a steam turbine. The last development that has been performed on CAPTUR is the extension to a calculation of a flow within a turbine operating under partial admission. For such turbines, it is now possible to calculate an internal flow field, and determine the efficiency, in a much more accurate way than with previous methods, which consist in an arbitrary efficiency correction on an averaged 1D flow calculation. From the aerodynamic point of view, partial admission involves specific losses in the first stage, then expansion and turbulent mixing just downstream of the first stage. Losses in the first stage are of very different types: windage, pumping and expansion at the ends of an admission sector. Their values have been estimated, with help of experimental results, and then expressed as a slow down coefficient applied to the relative velocity at the blade outlet. As for the flow downstream the first stage, a computational analysis has been made with specific 2D and 3D codes. It has led to define the numerical treatment established in the CAPTUR code. Some problems had to be solved to make compatible a quasi 3D formulation, making an average in the azimutal direction and using a streamline curvature method, with an absolute 3D phenomenon. Certain limitations of the working conditions were first adopted, but a generalization is on hand. The calculation of a nuclear HP steam turbine operating under partial admission has been performed. Calculation results are in good accordance with tests results, especially as regards the expansion line along the stages. The code CAPTUR will be particularly useful for the calculation

  10. ST-depression in right precordial leads with inferior STEMI and occluded right coronary artery: intertwined anatomy and ischemic areas.

    Science.gov (United States)

    De Gennaro, Luisa; Brunetti, Natale Daniele; Ruggiero, Massimo; Rutigliano, David; Locuratolo, Nicola; Di Biase, Matteo; Caldarola, Pasquale

    2017-10-01

    Right coronary artery (RCA) occlusion in inferior acute myocardial infarction is usually heralded by ST-elevation both in inferior and in right precordial leads. We report the case of a 68-year-old male, who presented marked ST-elevation in inferior leads, mirrored by ST-depression in anterior-septal and lateral leads. Right precordial lead electrocardiogram unexpectedly showed ST-depression V1R-V5R leads. Coronary angiography showed mid-left anterior descending (LAD) coronary near-complete occlusion with distal wrapping LAD. Left circumflex artery was not occluded, while RCA was occluded mid tract. The patient was treated with coronary angioplasty on RCA and LAD. Absence of ST-elevation in right precordial leads may be presumably explained by the presence of a large ischemic area distal to mid-LAD near-occlusive stenosis and of a long-wrapping LAD. Complex coronary anatomy and intertwined ischemic areas may underlie apparently discording electrocardiograms.

  11. On Alternative Approaches to 3D Image Perception: Monoscopic 3D Techniques

    Science.gov (United States)

    Blundell, Barry G.

    2015-06-01

    In the eighteenth century, techniques that enabled a strong sense of 3D perception to be experienced without recourse to binocular disparities (arising from the spatial separation of the eyes) underpinned the first significant commercial sales of 3D viewing devices and associated content. However following the advent of stereoscopic techniques in the nineteenth century, 3D image depiction has become inextricably linked to binocular parallax and outside the vision science and arts communities relatively little attention has been directed towards earlier approaches. Here we introduce relevant concepts and terminology and consider a number of techniques and optical devices that enable 3D perception to be experienced on the basis of planar images rendered from a single vantage point. Subsequently we allude to possible mechanisms for non-binocular parallax based 3D perception. Particular attention is given to reviewing areas likely to be thought-provoking to those involved in 3D display development, spatial visualization, HCI, and other related areas of interdisciplinary research.

  12. 3D Modelling and Printing Technology to Produce Patient-Specific 3D Models.

    Science.gov (United States)

    Birbara, Nicolette S; Otton, James M; Pather, Nalini

    2017-11-10

    A comprehensive knowledge of mitral valve (MV) anatomy is crucial in the assessment of MV disease. While the use of three-dimensional (3D) modelling and printing in MV assessment has undergone early clinical evaluation, the precision and usefulness of this technology requires further investigation. This study aimed to assess and validate 3D modelling and printing technology to produce patient-specific 3D MV models. A prototype method for MV 3D modelling and printing was developed from computed tomography (CT) scans of a plastinated human heart. Mitral valve models were printed using four 3D printing methods and validated to assess precision. Cardiac CT and 3D echocardiography imaging data of four MV disease patients was used to produce patient-specific 3D printed models, and 40 cardiac health professionals (CHPs) were surveyed on the perceived value and potential uses of 3D models in a clinical setting. The prototype method demonstrated submillimetre precision for all four 3D printing methods used, and statistical analysis showed a significant difference (p3D printed models, particularly using multiple print materials, were considered useful by CHPs for preoperative planning, as well as other applications such as teaching and training. This study suggests that, with further advances in 3D modelling and printing technology, patient-specific 3D MV models could serve as a useful clinical tool. The findings also highlight the potential of this technology to be applied in a variety of medical areas within both clinical and educational settings. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  13. Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder

    OpenAIRE

    Xi, Er-Ping; Zhu, Jian; Zhu, Shui-Bo; Yin, Gui-Lin; Liu, Yong; Dong, Yong-Qiang; Zhang, Yu; Xia, Feng

    2012-01-01

    OBJECTIVE: Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS: We treated three patients with post-traumatic ventricular septal defects caused by stab wounds with knives. After the heart wound was repaired,...

  14. Adherent Raindrop Modeling, Detectionand Removal in Video.

    Science.gov (United States)

    You, Shaodi; Tan, Robby T; Kawakami, Rei; Mukaigawa, Yasuhiro; Ikeuchi, Katsushi

    2016-09-01

    Raindrops adhered to a windscreen or window glass can significantly degrade the visibility of a scene. Modeling, detecting and removing raindrops will, therefore, benefit many computer vision applications, particularly outdoor surveillance systems and intelligent vehicle systems. In this paper, a method that automatically detects and removes adherent raindrops is introduced. The core idea is to exploit the local spatio-temporal derivatives of raindrops. To accomplish the idea, we first model adherent raindrops using law of physics, and detect raindrops based on these models in combination with motion and intensity temporal derivatives of the input video. Having detected the raindrops, we remove them and restore the images based on an analysis that some areas of raindrops completely occludes the scene, and some other areas occlude only partially. For partially occluding areas, we restore them by retrieving as much as possible information of the scene, namely, by solving a blending function on the detected partially occluding areas using the temporal intensity derivative. For completely occluding areas, we recover them by using a video completion technique. Experimental results using various real videos show the effectiveness of our method.

  15. Procedure for preparation of 3-fluor-D-alanine, 2-deutero-3-fluor-D-alanine and 2,3,3-trideutero-3-fluor-D-alanine and their salts

    International Nuclear Information System (INIS)

    Kollonitsch, J.; Kahan, F.M.

    1971-01-01

    Procedures for the preparation of 3-fluor-D-alanine, 2-deutero-3-fluor-D-alanine and 2,3,3-trideutero-3-fluor-D-alanine, and salts of these compounds, are described. These new compounds are useful antibacterial substances not only applicable in the disinfection of pharmaceutical, dental and medical equipment, but also in the treatment of diseases caused by bacteria, and may be administered orally. While 3-fluor-L-alanine metabolises rapidly with toxic results, 3-fluor-D-alanine is much more slowly broken down in vivo and is not harmful in normal doses. Further it has been found that deuteration gives new deutero-analogues which are less subject to metabolic breaking down and still retain the antibacterial strength of the original compound. The in vivo activity is thereby increased and maintained. (JIW)

  16. Effects of acute and chronic treatments with dopamine D2 and D3 receptor ligands on cocaine versus food choice in rats

    DEFF Research Database (Denmark)

    Thomsen, Morgane; Barrett, Andrew C.; Butler, Paul

    2017-01-01

    effects of dopamine D2- and D3-preferring ligands on choice between intravenous cocaine and palatable food in rats. Under baseline conditions, cocaine maintained dose-dependent increases in cocaine choice and reciprocal decreases in food choice. Acutely, the D2 agonist R-(2)-norpropylapomorphine (NPA......) and antagonist L-741,626 [3-[[4-(4-chlorophenyl)-4-hydroxypiperidin-lyl] methyl-1H-indole] produced leftward and rightward shifts in cocaine dose-effect curves, respectively, whereas the partial agonist terguride had no effect. All three drugs dose-dependently decreased food-maintained responding. Chronically......, the effects of R-(2)-norpropylapomorphine and L-741,626 on cocaine selfadministration showed marked tolerance, whereas suppression of food-reinforced behavior persisted. Acute effects of the D3 ligands were less systematic and most consistent with nonselective decreases in cocaine- and food-maintained...

  17. Accurate and reproducible reconstruction of coronary arteries and endothelial shear stress calculation using 3D OCT: comparative study to 3D IVUS and 3D QCA.

    Science.gov (United States)

    Toutouzas, Konstantinos; Chatzizisis, Yiannis S; Riga, Maria; Giannopoulos, Andreas; Antoniadis, Antonios P; Tu, Shengxian; Fujino, Yusuke; Mitsouras, Dimitrios; Doulaverakis, Charalampos; Tsampoulatidis, Ioannis; Koutkias, Vassilis G; Bouki, Konstantina; Li, Yingguang; Chouvarda, Ioanna; Cheimariotis, Grigorios; Maglaveras, Nicos; Kompatsiaris, Ioannis; Nakamura, Sunao; Reiber, Johan H C; Rybicki, Frank; Karvounis, Haralambos; Stefanadis, Christodoulos; Tousoulis, Dimitris; Giannoglou, George D

    2015-06-01

    Geometrically-correct 3D OCT is a new imaging modality with the potential to investigate the association of local hemodynamic microenvironment with OCT-derived high-risk features. We aimed to describe the methodology of 3D OCT and investigate the accuracy, inter- and intra-observer agreement of 3D OCT in reconstructing coronary arteries and calculating ESS, using 3D IVUS and 3D QCA as references. 35 coronary artery segments derived from 30 patients were reconstructed in 3D space using 3D OCT. 3D OCT was validated against 3D IVUS and 3D QCA. The agreement in artery reconstruction among 3D OCT, 3D IVUS and 3D QCA was assessed in 3-mm-long subsegments using lumen morphometry and ESS parameters. The inter- and intra-observer agreement of 3D OCT, 3D IVUS and 3D QCA were assessed in a representative sample of 61 subsegments (n = 5 arteries). The data processing times for each reconstruction methodology were also calculated. There was a very high agreement between 3D OCT vs. 3D IVUS and 3D OCT vs. 3D QCA in terms of total reconstructed artery length and volume, as well as in terms of segmental morphometric and ESS metrics with mean differences close to zero and narrow limits of agreement (Bland-Altman analysis). 3D OCT exhibited excellent inter- and intra-observer agreement. The analysis time with 3D OCT was significantly lower compared to 3D IVUS. Geometrically-correct 3D OCT is a feasible, accurate and reproducible 3D reconstruction technique that can perform reliable ESS calculations in coronary arteries. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. The 3d8-(3d74p + 3p53d9) transitions in Br X: A striking case of configuration interaction

    International Nuclear Information System (INIS)

    Kleef, T.A.M. van; Uylings, P.H.M.; Ryabtsev, A.N.; Podobedova, L.I.; Joshi, Y.N.

    1988-01-01

    The spectrum of nine times ionized bromine (Br X) was photographed in the 90-120 A wavelength region on a variety of grazing incidence spectrographs using an open spark and a triggered spark as light sources. The analysis of the 3d 8 -(3d 7 4p + 3p 5 3d 9 ) transitions has resulted in establishing all 9 levels of the 3d 8 configuration, all 12 levels of the 3p 5 3d 9 configuration and 99 out of 110 levels of the 3d 7 4p configuration. The excitation probability of the 3p inner-shell electron increases with nuclear charge and in Br X is comparable with the excitation probability of the optical electrons resulting in a very strong configuration interaction between the 3p 5 3d 9 and 3d 7 4p configurations. Parametric calculations treating these configurations as one super configuration support the analysis. Two hundred and thirty two lines have been classified in this spectrum. (orig.)

  19. Supplementation with partially hydrogenated oil in grazing dairy cows in early lactation.

    Science.gov (United States)

    Schroeder, G F; Gagliostro, G A; Becu-Villalobos, D; Lacau-Mengido, I

    2002-03-01

    Effects of partially hydrogenated oil on performance, loss of body weight and body condition score, and blood metabolite and hormone concentrations were evaluated in 37 multiparous Holstein cows in grazing conditions during the first 100 d of lactation. Six additional Holstein cows, each fitted with a ruminal cannula, were allocated to a replicated 3 x 3 Latin square to evaluate effects of supplemental fat on rumen environment and pasture digestion. All cows grazed mixed pastures based on alfalfa (Medicago sativa) and orchardgrass (Dactylis glomerata L.) and received 5.4 kg/d of a basal concentrate to which 0, 0.5, or 1 kg/cow per day of partially hydrogenated oil (melting point 58 to 60 degrees C) containing 30.3, 34.9, 21.8, and 3.3% of C16:0, C18:0, C18:1, and C182, respectively, was added. Feeding 1 kg/d of supplemental fat increased fat-corrected milk from 23.4 to 26.3 kg/d, milk fat content from 3.44 to 3.78%, and milk fat yield from 0.87 to 1.03 kg/d compared to control. Milk protein percentage and yield were not affected. Cows fed 1 kg/d of fat increased the content and yield of C16:0 and C18:0 in milk compared with cows fed no added oil. Dry matter intake (DMI) from pasture decreased from 17.8 kg/d for control cows to 13.6 kg/d for cows fed 1 kg of oil, whereas DMI from concentrate was higher for cows fed 1 kg/d of fat (6.0 kg/d) than for controls (5.2 kg/d). Supplemental fat did not affect total dry matter or estimated energy intake and did not change losses of body weight or body condition scores. Plasma concentrations of nonesterified fatty acids, insulin, somatotrophin, and insulin-like growth factor-I did not differ among treatments. Concentration of plasma triglycerides was lowered from 318.5 to 271.2 mg/dl, whereas plasma cholesterol was elevated from 185.0 to 235.8 mg/dl in cows receiving 1 kg/d of supplemental fat compared with controls. Responses to lipolytic or insulin challenges were not affected by feeding oil. Supplemental fat did not affect

  20. "Handling" seismic hazard: 3D printing of California Faults

    Science.gov (United States)

    Kyriakopoulos, C.; Potter, M.; Richards-Dinger, K. B.

    2017-12-01

    As earth scientists, we face the challenge of how to explain and represent our work and achievements to the general public. Nowadays, this problem is partially alleviated by the use of modern visualization tools such as advanced scientific software (Paraview.org), high resolution monitors, elaborate video simulations, and even 3D Virtual Reality goggles. However, the ability to manipulate and examine a physical object in 3D is still an important tool to connect better with the public. For that reason, we are presenting a scaled 3D printed version of the complex network of earthquake faults active in California based on that used by the Uniform California Earthquake Rupture Forecast 3 (UCERF3) (Field et al., 2013). We start from the fault geometry in the UCERF3.1 deformation model files. These files contain information such as the coordinates of the surface traces of the faults, dip angle, and depth extent. The fault specified in the above files are triangulated at 1km resolution and exported as a facet (.fac) file. The facet file is later imported into the Trelis 15.1 mesh generator (csimsoft.com). We use Trelis to perform the following three operations: First, we scale down the model so that 100 mm corresponds to 100km. Second, we "thicken" the walls of the faults; wall thickness of at least 1mm is necessary in 3D printing. We thicken fault geometry by 1mm on each side of the faults for a total of 2mm thickness. Third, we break down the model into parts that will fit the printing bed size ( 25 x 20mm). Finally, each part is exported in stereolithography format (.stl). For our project, we are using the 3D printing facility within the Creat'R Lab in the UC Riverside Orbach Science Library. The 3D printer is a MakerBot Replicator Desktop, 5th Generation. The resolution of print is 0.2mm (Standard quality). The printing material is the MakerBot PLA Filament, 1.75 mm diameter, large Spool, green. The most complex part of the display model requires approximately 17

  1. ROOFN3D: DEEP LEARNING TRAINING DATA FOR 3D BUILDING RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    A. Wichmann

    2018-05-01

    Full Text Available Machine learning methods have gained in importance through the latest development of artificial intelligence and computer hardware. Particularly approaches based on deep learning have shown that they are able to provide state-of-the-art results for various tasks. However, the direct application of deep learning methods to improve the results of 3D building reconstruction is often not possible due, for example, to the lack of suitable training data. To address this issue, we present RoofN3D which provides a new 3D point cloud training dataset that can be used to train machine learning models for different tasks in the context of 3D building reconstruction. It can be used, among others, to train semantic segmentation networks or to learn the structure of buildings and the geometric model construction. Further details about RoofN3D and the developed data preparation framework, which enables the automatic derivation of training data, are described in this paper. Furthermore, we provide an overview of other available 3D point cloud training data and approaches from current literature in which solutions for the application of deep learning to unstructured and not gridded 3D point cloud data are presented.

  2. Comparative evaluation of HD 2D/3D laparoscopic monitors and benchmarking to a theoretically ideal 3D pseudodisplay: even well-experienced laparoscopists perform better with 3D.

    Science.gov (United States)

    Wilhelm, D; Reiser, S; Kohn, N; Witte, M; Leiner, U; Mühlbach, L; Ruschin, D; Reiner, W; Feussner, H

    2014-08-01

    Though theoretically superior to standard 2D visualization, 3D video systems have not yet achieved a breakthrough in laparoscopy. The latest 3D monitors, including autostereoscopic displays and high-definition (HD) resolution, are designed to overcome the existing limitations. We performed a randomized study on 48 individuals with different experience levels in laparoscopy. Three different 3D displays (glasses-based 3D monitor, autostereoscopic display, and a mirror-based theoretically ideal 3D display) were compared to a 2D HD display by assessing multiple performance and mental workload parameters and rating the subjects during a laparoscopic suturing task. Electromagnetic tracking provided information on the instruments' pathlength, movement velocity, and economy. The usability, the perception of visual discomfort, and the quality of image transmission of each monitor were subjectively rated. Almost all performance parameters were superior with the conventional glasses-based 3D display compared to the 2D display and the autostereoscopic display, but were often significantly exceeded by the mirror-based 3D display. Subjects performed a task faster and with greater precision when visualization was achieved with the 3D and the mirror-based display. Instrument pathlength was shortened by improved depth perception. Workload parameters (NASA TLX) did not show significant differences. Test persons complained of impaired vision while using the autostereoscopic monitor. The 3D and 2D displays were rated user-friendly and applicable in daily work. Experienced and inexperienced laparoscopists profited equally from using a 3D display, with an improvement in task performance about 20%. Novel 3D displays improve laparoscopic interventions as a result of faster performance and higher precision without causing a higher mental workload. Therefore, they have the potential to significantly impact the further development of minimally invasive surgery. However, as shown by the

  3. A fast rebinning algorithm for 3D positron emission tomography using John's equation

    Science.gov (United States)

    Defrise, Michel; Liu, Xuan

    1999-08-01

    Volume imaging in positron emission tomography (PET) requires the inversion of the three-dimensional (3D) x-ray transform. The usual solution to this problem is based on 3D filtered-backprojection (FBP), but is slow. Alternative methods have been proposed which factor the 3D data into independent 2D data sets corresponding to the 2D Radon transforms of a stack of parallel slices. Each slice is then reconstructed using 2D FBP. These so-called rebinning methods are numerically efficient but are approximate. In this paper a new exact rebinning method is derived by exploiting the fact that the 3D x-ray transform of a function is the solution to the second-order partial differential equation first studied by John. The method is proposed for two sampling schemes, one corresponding to a pair of infinite plane detectors and another one corresponding to a cylindrical multi-ring PET scanner. The new FORE-J algorithm has been implemented for this latter geometry and was compared with the approximate Fourier rebinning algorithm FORE and with another exact rebinning algorithm, FOREX. Results with simulated data demonstrate a significant improvement in accuracy compared to FORE, while the reconstruction time is doubled. Compared to FOREX, the FORE-J algorithm is slightly less accurate but more than three times faster.

  4. Minimally invasive vascular imaging using 3D-CTA and 3D-MRA. Update

    International Nuclear Information System (INIS)

    Hayashi, Hiromitsu; Kawamata, Hiroshi; Takagi, Ryo; Amano, Yasuo; Wakabayashi, Hiroyuki; Ichikawa, Kazuo; Kumazaki, Tatsuo

    1998-01-01

    Conventional angiography is considered the standard of reference for diagnostic imaging of vascular diseases with respect to its temporal and spatial resolution. This procedure, however is invasive and repeated studies are difficult, and arterial complications are occasionally associated in catheter-based conventional angiography. Recent advances in diagnostic imaging have facilitated three-dimensional CT angiography (3D-CTA) using the volumetric acquisition capabilities inherent in spiral CT and three-dimensional MR angiography (3D-MRA) using the 3D gradient-echo sequence with a bolus injection of Gd-DTPA. These techniques can provide vascular images exceedingly similar to conventional angiograms within a short acquisition time. 3D-CTA and 3D-MRA are considered to be promising, minimally invasive methods for obtaining images of the vasculature, and alternatives to catheter angiography. This study reviews the current status of 3D-CTA and 3D-MRA, with emphasis on the clinical usefulness of three-dimensional diagnostic imaging for the evaluation of diverse vascular pathologies. (author)

  5. 3dRPC: a web server for 3D RNA-protein structure prediction.

    Science.gov (United States)

    Huang, Yangyu; Li, Haotian; Xiao, Yi

    2018-04-01

    RNA-protein interactions occur in many biological processes. To understand the mechanism of these interactions one needs to know three-dimensional (3D) structures of RNA-protein complexes. 3dRPC is an algorithm for prediction of 3D RNA-protein complex structures and consists of a docking algorithm RPDOCK and a scoring function 3dRPC-Score. RPDOCK is used to sample possible complex conformations of an RNA and a protein by calculating the geometric and electrostatic complementarities and stacking interactions at the RNA-protein interface according to the features of atom packing of the interface. 3dRPC-Score is a knowledge-based potential that uses the conformations of nucleotide-amino-acid pairs as statistical variables and that is used to choose the near-native complex-conformations obtained from the docking method above. Recently, we built a web server for 3dRPC. The users can easily use 3dRPC without installing it locally. RNA and protein structures in PDB (Protein Data Bank) format are the only needed input files. It can also incorporate the information of interface residues or residue-pairs obtained from experiments or theoretical predictions to improve the prediction. The address of 3dRPC web server is http://biophy.hust.edu.cn/3dRPC. yxiao@hust.edu.cn.

  6. On-site bridge inspection with partial CT by 3.95Mev X-band linac source

    International Nuclear Information System (INIS)

    Wu, Wenjing; Zhu, Haito; Jin, Ming

    2012-01-01

    Since more and more bridges built several decades ago in Japan have become aged and dangerous, the non-destructive evaluation of those bridges is really an urgent problem. CT system with portable 3.95MeV linacs for bridge inspection is considered to work on-site, considering the law of Japanese radiation protection allows using linacs up to 4MeV outside radiation controlled area. The system would confirm the internal steel situation of bridges and analyze structural strain and stress with 3D model built from sectional imaging to evaluate load-bearing performance. The reconstruction process of bridge imaging is based on partial scanned data because bridge shape confines possible scanning angle to smaller than 180deg and a few translations. A small concrete sample with internal steel bars and attachment accessories is scanned in laboratory as preliminary work. (author)

  7. Vitamin D3 increases in abdominal subcutaneous fat tissue after supplementation with vitamin D3

    DEFF Research Database (Denmark)

    Didriksen, Allan; Burild, Anders; Jakobsen, Jette

    2015-01-01

    stored in all adipose tissue in the body, the median body store was 6.6 mg vitamin D-3 and 0.12 mg 25(OH)D-3 in those given vitamin D-3. Conclusions: Subcutaneous adipose tissue may store large amounts of vitamin D-3. The clinical importance of this storage needs to be determined.......Objective: The objective was to assess the amount of vitamin D-3 stored in adipose tissue after long-term supplementation with high dose vitamin D-3. Design: A cross-sectional study on 29 subjects with impaired glucose tolerance who had participated in a randomized controlled trial with vitamin D-3...... 20 000 IU (500 mu g) per week vs placebo for 3-5 years. Methods: Abdominal subcutaneous fat tissue was obtained by needle biopsy for the measurements of vitamin D-3 and 25-hydroxyvitamin D-3 (25(OH)D-3). Body fat was measured with dual-energy X-ray absorptiometry, and serum 25(OH)D-3 level...

  8. 3D analysis of semiconductor devices: A combination of 3D imaging and 3D elemental analysis

    Science.gov (United States)

    Fu, Bianzhu; Gribelyuk, Michael A.

    2018-04-01

    3D analysis of semiconductor devices using a combination of scanning transmission electron microscopy (STEM) Z-contrast tomography and energy dispersive spectroscopy (EDS) elemental tomography is presented. 3D STEM Z-contrast tomography is useful in revealing the depth information of the sample. However, it suffers from contrast problems between materials with similar atomic numbers. Examples of EDS elemental tomography are presented using an automated EDS tomography system with batch data processing, which greatly reduces the data collection and processing time. 3D EDS elemental tomography reveals more in-depth information about the defect origin in semiconductor failure analysis. The influence of detector shadowing and X-rays absorption on the EDS tomography's result is also discussed.

  9. GDC 360 for the endovascular treatment of intracranial aneurysms: a matched-pair study analysing angiographic outcomes with GDC 3D coils in 38 patients

    International Nuclear Information System (INIS)

    Taschner, Christian A.; Thines, Laurent; Lejeune, Jean-Paul; El-Mahdy, Mohamed; Rachdi, Henda; Gauvrit, Jean-Yves; Pruvo, Jean-Pierre; Leclerc, Xavier

    2009-01-01

    The purpose of this study was to determine whether coil embolisation with a new complex-shaped Guglielmi Detachable Coil (GDC 360 ; Boston Scientific Neurovascular, Fremont, CA, USA) has any effect on the stability of aneurysm occlusion. Fifty-one consecutive patients with intracranial aneurysms treated with GDC 360 were included. Angiographic results and adverse neurological events during the follow-up period were recorded. For 38 patients treated with GDC 360 with available follow-up data, a corresponding patient treated with GDC 3D was identified from our database. Matches were sought for rupture status, location, aneurysmal size, and neck size. The angiographic outcome of these matched controls at 6 months was compared to aneurysms treated with GDC 360 . Initial angiographic controls for 38 patients treated with GDC 360 showed complete occlusion in 32 aneurysms, and a neck remnant in six. At 6-month follow-up, complete occlusion was found in 29, a neck remnant in eight, and a residual aneurysm in one. One patient treated with GDC 360 needed retreatment for a major recanalisation. In 38 matched patients treated with GDC 3D, initial angiographic controls found complete aneurysmal occlusion in 30 aneurysms and a residual neck in 8. At 6-month follow-up, 24 aneurysms were completely occluded, ten showed a neck remnant, and residual aneurysms were seen in four. Four patients, treated with GDC 3D, were retreated for major aneurysm recanalisations. Our data suggests that endovascular coil embolisation with GDC 360 might improve long-term stability of coiled aneurysms when compared to GDC 3D. (orig.)

  10. VITOM 3D: Preliminary Experience in Cranial Surgery.

    Science.gov (United States)

    Rossini, Zefferino; Cardia, Andrea; Milani, Davide; Lasio, Giovanni Battista; Fornari, Maurizio; D'Angelo, Vincenzo

    2017-11-01

    Optimal vision and ergonomics are important factors contributing to achievement of good results during neurosurgical interventions. The operating microscope and the endoscope have partially filled the gap between the need for good surgical vision and maintenance of a comfortable posture during surgery. Recently, a new technology called video-assisted telescope operating monitor or exoscope has been used in cranial surgery. The main drawback with previous prototypes was lack of stereopsis. We present the first case report of cranial surgery performed using the VITOM 3D, an exoscope conjugating 4K resolution view and three-dimensional technology, and discuss advantages and disadvantages compared with the operating microscope. A 50-year-old patient with vertigo and headache linked to a petrous ridge meningioma underwent surgery using the VITOM 3D. Complete removal of the tumor and resolution of symptoms were achieved. The telescope was maintained over the surgical field for the duration of the procedure; a video monitor was placed at 2 m from the surgeons; and a control unit allowed focusing, magnification, and repositioning of the camera. VITOM 3D is a video system that has overcome the lack of stereopsis, a major drawback of previous exoscope models. It has many advantages regarding ergonomics, versatility, and depth of field compared with the operating microscope, but the holder arm and the mechanism of repositioning, refocusing, and magnification need to be ameliorated. Surgeons should continue to use the technology they feel confident with, unless a distinct advantage with newer technologies can be demonstrated. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Meta-analysis of adjunctive levetiracetam in refractory partial sei

    Directory of Open Access Journals (Sweden)

    ZHANG Ying

    2012-10-01

    Full Text Available Objective To evaluate the effects and tolerability of adjunctive levetiracetam (LEV in refractory partial seizures. Methods Relevant research articles about randomized controlled trials of adjunctive LEV in refractory partial seizures from January 1998 to December 2010 were retrieved from Cochrane Library, MEDLINE, EMbase, Social Sciences Citation Index (SSCI, VIP, Chinese National Knowledge Infrastructure (CNKI database, China Biology Medicine (CBM. Two reviewers independently evaluated the quality of the included articles and abstracted the data. A Meta-analysis was conducted by using RevMan 5.0 software. Results According to the enrollment criteria, eleven prospective, randomized controlled clinical trials with a total of 1192 in LEV group and 789 in placebo group were finally selected. The reduction in three endpoints (a 50% or greater reduction of partial seizure frequency per week, a 75% or greater reduction of partial seizure frequency per week and seizure free was significant in LEV group than placebo group. There was no significance between LEV group and placebo group in the withdrawl rate (1000 mg/d: OR = 1.180, 95%CI: 0.690-2.010, P = 0.540; 2000 mg/d: OR = 1.530, 95%CI: 0.770-3.030, P = 0.230; 3000 mg/d: OR = 1.000, 95% CI: 0.620-1.600, P = 1.000. The following adverse events were associated with LEV: somnolence (OR = 1.720, 95%CI: 1.280-2.310, P = 0.000, dizziness (OR = 1.490, 95%CI: 1.000-2.220, P = 0.050, asthenia (OR = 1.670, 95%CI: 1.140-2.240, P = 0.008, nasopharyngitis (OR = 1.120, 95% CI: 0.710-1.760, P = 0.630, psychiatric and behavioral abnormalities (OR = 2.120, 95% CI: 1.370-3.280, P = 0.000. Conclusion LEV is effective and well tolerated when added to existing therapy in patients with refractory partial seizures compared with control drugs. Further studies are needed to identify the effects of monotherapy of LEV in partial seizures.

  12. Cast Partial Denture versus Acrylic Partial Denture for Replacement of Missing Teeth in Partially Edentulous Patients

    Directory of Open Access Journals (Sweden)

    Pramita Suwal

    2017-03-01

    Full Text Available Aim: To compare the effects of cast partial denture with conventional all acrylic denture in respect to retention, stability, masticatory efficiency, comfort and periodontal health of abutments. Methods: 50 adult partially edentulous patient seeking for replacement of missing teeth having Kennedy class I and II arches with or without modification areas were selected for the study. Group-A was treated with cast partial denture and Group-B with acrylic partial denture. Data collected during follow-up visit of 3 months, 6 months, and 1 year by evaluating retention, stability, masticatory efficiency, comfort, periodontal health of abutment. Results: Chi-square test was applied to find out differences between the groups at 95% confidence interval where p = 0.05. One year comparison shows that cast partial denture maintained retention and stability better than acrylic partial denture (p< 0.05. The masticatory efficiency was significantly compromising from 3rd month to 1 year in all acrylic partial denture groups (p< 0.05. The comfort of patient with cast partial denture was maintained better during the observation period (p< 0.05. Periodontal health of abutment was gradually deteriorated in all acrylic denture group (p

  13. TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Balasubramoniam, A; Bednarek, D; Rudin, S; Ionita, C [Toshiba Stroke and Vascular Research Centre, SUNY at Buffalo (United States)

    2016-06-15

    Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametric maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  14. TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

    International Nuclear Information System (INIS)

    Balasubramoniam, A; Bednarek, D; Rudin, S; Ionita, C

    2016-01-01

    Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametric maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  15. Molecular characterization of amino acid deletion in VP1 (1D) protein and novel amino acid substitutions in 3D polymerase protein of foot and mouth disease virus subtype A/Iran87.

    Science.gov (United States)

    Esmaelizad, Majid; Jelokhani-Niaraki, Saber; Hashemnejad, Khadije; Kamalzadeh, Morteza; Lotfi, Mohsen

    2011-12-01

    The nucleotide sequence of the VP1 (1D) and partial 3D polymerase (3D(pol)) coding regions of the foot and mouth disease virus (FMDV) vaccine strain A/Iran87, a highly passaged isolate (~150 passages), was determined and aligned with previously published FMDV serotype A sequences. Overall analysis of the amino acid substitutions revealed that the partial 3D(pol) coding region contained four amino acid alterations. Amino acid sequence comparison of the VP1 coding region of the field isolates revealed deletions in the highly passaged Iranian isolate (A/Iran87). The prominent G-H loop of the FMDV VP1 protein contains the conserved arginine-glycine-aspartic acid (RGD) tripeptide, which is a well-known ligand for a specific cell surface integrin. Despite losing the RGD sequence of the VP1 protein and an Asp(26)→Glu substitution in a beta sheet located within a small groove of the 3D(pol) protein, the virus grew in BHK 21 suspension cell cultures. Since this strain has been used as a vaccine strain, it may be inferred that the RGD deletion has no critical role in virus attachment to the cell during the initiation of infection. It is probable that this FMDV subtype can utilize other pathways for cell attachment.

  16. Three-Dimensional Flow Generated by a Partially Penetrating Well in a Two-Aquifer System

    Science.gov (United States)

    Sepulveda, N.

    2007-12-01

    An analytical solution is presented for three-dimensional (3D) flow in a confined aquifer and the overlying storative semiconfining layer and unconfined aquifer. The equation describing flow caused by a partially penetrating production well is solved analytically to provide a method to accurately determine the hydraulic parameters in the confined aquifer, semiconfining layer, and unconfined aquifer from aquifer-test data. Previous solutions for a partially penetrating well did not account for 3D flow or storativity in the semiconfining unit. The 3D and two- dimensional (2D) flow solutions in the semiconfining layer are compared for various hydraulic conductivity ratios between the aquifer and the semiconfining layer. Analysis of the drawdown data from an aquifer test in central Florida showed that the 3D solution in the semiconfining layer provides a more unique identification of the hydraulic parameters than the 2D solution. The analytical solution could be used to analyze, with higher accuracy, the effect that pumping water from the lower aquifer in a two-aquifer system has on wetlands.

  17. Phasic dopamine release drives rapid activation of striatal D2-receptors

    Science.gov (United States)

    Marcott, Pamela F; Mamaligas, Aphroditi A; Ford, Christopher P

    2014-01-01

    Summary Striatal dopamine transmission underlies numerous goal-directed behaviors. Medium spiny neurons (MSNs) are a major target of dopamine in the striatum. However, as dopamine does not directly evoke a synaptic event in MSNs, the time course of dopamine signaling in these cells remains unclear. To examine how dopamine release activates D2-receptors on MSNs, G-protein activated inwardly rectifying potassium (GIRK2; Kir 3.2) channels were virally overexpressed in the striatum and the resulting outward currents were used as a sensor of D2-receptor activation. Electrical and optogenetic stimulation of dopamine terminals evoked robust D2-receptor inhibitory post-synaptic currents (IPSCs) in GIRK2-expressing MSNs that occurred in under a second. Evoked D2-IPSCs could be driven by repetitive stimulation and were not occluded by background dopamine tone. Together, the results indicate that D2-receptors on MSNs exhibit functional low affinity and suggest that striatal D2-receptors can encode both tonic and phasic dopamine signals. PMID:25242218

  18. Vitamin D-3 and 25-hydroxyvitamin D-3 in raw and cooked pork cuts

    DEFF Research Database (Denmark)

    Clausen, Ina; Jakobsen, Jette; Leth, Torben

    2003-01-01

    The contents of vitamin D-3 and its metabolically active metabolite 25-hydroxyvitamin D-3 (25OHD(3)) were examined by HPLC in different parts of four common raw pork cuts (loin boneless, leg inside, thin belly, neck) and in cooked meat (loin boneless). In whole raw pork cuts, varying in fat content......, and that rind, despite its limited fat content, has a high concentration of vitamin D-3 and 25OHD(3). Cooking increased vitamin D-3 and 25OHD(3) calculated per 100 g of tissue in all parts and in the whole cut (in whole cuts in raw and cooked meat, respectively: vitamin D-3: 0.15 (0.08-0.24) mug/100 g and 0...... 25OHD(3) contributes significantly to vitamin D activity. Food databases should include concentrations of both vitamin D and 25OHD(3). (C) 2003 Elsevier Ltd. All rights reserved....

  19. Structure of the Human Dopamine D3 Receptor in Complex with a D2/D3 Selective Antagonist

    Energy Technology Data Exchange (ETDEWEB)

    Chien, Ellen Y.T.; Liu, Wei; Zhao, Qiang; Katritch, Vsevolod; Han, Gye Won; Hanson, Michael A.; Shi, Lei; Newman, Amy Hauck; Javitch, Jonathan A.; Cherezov, Vadim; Stevens, Raymond C. (Cornell); (Scripps); (NIDA); (Columbia); (UCSD); (Receptos)

    2010-11-30

    Dopamine modulates movement, cognition, and emotion through activation of dopamine G protein-coupled receptors in the brain. The crystal structure of the human dopamine D3 receptor (D3R) in complex with the small molecule D2R/D3R-specific antagonist eticlopride reveals important features of the ligand binding pocket and extracellular loops. On the intracellular side of the receptor, a locked conformation of the ionic lock and two distinctly different conformations of intracellular loop 2 are observed. Docking of R-22, a D3R-selective antagonist, reveals an extracellular extension of the eticlopride binding site that comprises a second binding pocket for the aryl amide of R-22, which differs between the highly homologous D2R and D3R. This difference provides direction to the design of D3R-selective agents for treating drug abuse and other neuropsychiatric indications.

  20. Initial experience with 3D isotropic high-resolution 3 T MR arthrography of the wrist.

    Science.gov (United States)

    Sutherland, John K; Nozaki, Taiki; Kaneko, Yasuhito; J Yu, Hon; Rafijah, Gregory; Hitt, David; Yoshioka, Hiroshi

    2016-01-16

    Our study was performed to evaluate the image quality of 3 T MR wrist arthrograms with attention to ulnar wrist structures, comparing image quality of isotropic 3D proton density fat suppressed turbo spin echo (PDFS TSE) sequence versus standard 2D 3 T sequences as well as comparison with 1.5 T MR arthrograms. Eleven consecutive 3 T MR wrist arthrograms were performed and the following sequences evaluated: 3D isotropic PDFS, repetition time/echo time (TR/TE) 1400/28.3 ms, voxel size 0.35x0.35x0.35 mm, acquisition time 5 min; 2D coronal sequences with slice thickness 2 mm: T1 fat suppressed turbo spin echo (T1FS TSE) (TR/TE 600/20 ms); proton density (PD) TSE (TR/TE 3499/27 ms). A 1.5 T group of 18 studies with standard sequences were evaluated for comparison. All MR imaging followed fluoroscopically guided intra-articular injection of dilute gadolinium contrast. Qualitative assessment related to delineation of anatomic structures between 1.5 T and 3 T MR arthrograms was carried out using Mann-Whitney test and the differences in delineation of anatomic structures among each sequence in 3 T group were analyzed with Wilcoxon signed-rank test. Quantitative assessment of mean relative signal intensity (SI) and relative contrast measurements was performed using Wilcoxon signed-rank test. Mean qualitative scores for 3 T sequences were significantly higher than 1.5 T (p < 0.01), with isotropic 3D PDFS sequence having highest mean qualitative scores (p < 0.05). Quantitative analysis demonstrated no significant difference in relative signal intensity among the 3 T sequences. Significant differences were found in relative contrast between fluid-bone and fluid-fat comparing 3D and 2D PDFS (p < 0.01). 3D isotropic PDFS sequence showed promise in both qualitative and quantitative assessment, suggesting this may be useful for MR wrist arthrograms at 3 T. Primary reasons for diagnostic potential include the ability to make reformations in any

  1. Open 3D Projects

    Directory of Open Access Journals (Sweden)

    Felician ALECU

    2010-01-01

    Full Text Available Many professionals and 3D artists consider Blender as being the best open source solution for 3D computer graphics. The main features are related to modeling, rendering, shading, imaging, compositing, animation, physics and particles and realtime 3D/game creation.

  2. Modification of 3D milling machine to 3D printer

    OpenAIRE

    Taska, Abraham

    2014-01-01

    Tato práce se zabývá přestavbou gravírovací frézky na 3D tiskárnu. V první části se práce zabývá možnými technologiemi 3D tisku a možností jejich využití u přestavby. Dále jsou popsány a vybrány vhodné součásti pro přestavbu. V další části je realizováno řízení ohřevu podložky, trysky a řízení posuvu drátu pomocí softwaru TwinCat od společnosti Beckhoff na průmyslovém počítači. Výsledkem práce by měla být oživená 3D tiskárna. This thesis deals with rebuilding of engraving machine to 3D pri...

  3. Anti-3D Weapon Model Detection for Safe 3D Printing Based on Convolutional Neural Networks and D2 Shape Distribution

    Directory of Open Access Journals (Sweden)

    Giao N. Pham

    2018-03-01

    Full Text Available With the development of 3D printing, weapons are easily printed without any restriction from the production managers. Therefore, anti-3D weapon model detection is necessary issue in safe 3D printing to prevent the printing of 3D weapon models. In this paper, we would like to propose an anti-3D weapon model detection algorithm to prevent the printing of anti-3D weapon models for safe 3D printing based on the D2 shape distribution and an improved convolutional neural networks (CNNs. The purpose of the proposed algorithm is to detect anti-3D weapon models when they are used in 3D printing. The D2 shape distribution is computed from random points on the surface of a 3D weapon model and their geometric features in order to construct a D2 vector. The D2 vector is then trained by improved CNNs. The CNNs are used to detect anti-3D weapon models for safe 3D printing by training D2 vectors which have been constructed from the D2 shape distribution of 3D weapon models. Experiments with 3D weapon models proved that the D2 shape distribution of 3D weapon models in the same class is the same. Training and testing results also verified that the accuracy of the proposed algorithm is higher than the conventional works. The proposed algorithm is applied in a small application, and it could detect anti-3D weapon models for safe 3D printing.

  4. CASTLE3D - A Computer Aided System for Labelling Archaeological Excavations in 3D

    Science.gov (United States)

    Houshiar, H.; Borrmann, D.; Elseberg, J.; Nüchter, A.; Näth, F.; Winkler, S.

    2015-08-01

    Documentation of archaeological excavation sites with conventional methods and tools such as hand drawings, measuring tape and archaeological notes is time consuming. This process is prone to human errors and the quality of the documentation depends on the qualification of the archaeologist on site. Use of modern technology and methods in 3D surveying and 3D robotics facilitate and improve this process. Computer-aided systems and databases improve the documentation quality and increase the speed of data acquisition. 3D laser scanning is the state of the art in modelling archaeological excavation sites, historical sites and even entire cities or landscapes. Modern laser scanners are capable of data acquisition of up to 1 million points per second. This provides a very detailed 3D point cloud of the environment. 3D point clouds and 3D models of an excavation site provide a better representation of the environment for the archaeologist and for documentation. The point cloud can be used both for further studies on the excavation and for the presentation of results. This paper introduces a Computer aided system for labelling archaeological excavations in 3D (CASTLE3D). Consisting of a set of tools for recording and georeferencing the 3D data from an excavation site, CASTLE3D is a novel documentation approach in industrial archaeology. It provides a 2D and 3D visualisation of the data and an easy-to-use interface that enables the archaeologist to select regions of interest and to interact with the data in both representations. The 2D visualisation and a 3D orthogonal view of the data provide cuts of the environment that resemble the traditional hand drawings. The 3D perspective view gives a realistic view of the environment. CASTLE3D is designed as an easy-to-use on-site semantic mapping tool for archaeologists. Each project contains a predefined set of semantic information that can be used to label findings in the data. Multiple regions of interest can be joined under

  5. Do-It-Yourself: 3D Models of Hydrogenic Orbitals through 3D Printing

    Science.gov (United States)

    Griffith, Kaitlyn M.; de Cataldo, Riccardo; Fogarty, Keir H.

    2016-01-01

    Introductory chemistry students often have difficulty visualizing the 3-dimensional shapes of the hydrogenic electron orbitals without the aid of physical 3D models. Unfortunately, commercially available models can be quite expensive. 3D printing offers a solution for producing models of hydrogenic orbitals. 3D printing technology is widely…

  6. 3D motion graphics for 2D artists conquering the 3rd dimension

    CERN Document Server

    Byrne, Bill

    2011-01-01

    Add 3D to your mograph skillset! For the experienced 2D artist, this lavishly illustrated, 4 color book presents the essentials to building and compositing 3D elements into your 2D world of film and broadcast. Concepts and techniques are presented in concise, step-by-step tutorials, hundreds of which are featured throughout. Featured applications include Photoshop, Illustrator, After Effects, and Cinema 4D. Lessons include exploring the expanded 3D functionality of the Adobe Creative Suite applications (After Effects, Photoshop, and Illustrator) through a series of practical tutorials. More

  7. 3D Systems” ‘Stuck in the Middle’ of the 3D Printer Boom?

    NARCIS (Netherlands)

    A. Hoffmann (Alan)

    2014-01-01

    textabstract3D Systems, the pioneer of 3D printing, predicted a future where "kids from 8 to 80" could design and print their ideas at home. By 2013, 9 years after the creation of the first working 3D printer, there were more than 30 major 3D printing companies competing for market share. 3DS and

  8. Investigation of variability in image acquisition and contouring during 3D ultrasound guidance for partial breast irradiation

    International Nuclear Information System (INIS)

    Landry, Anthony; Olivotto, Ivo; Beckham, Wayne; Berrang, Tanya; Gagne, Isabelle; Popescu, Carmen; Mitchell, Tracy; Vey, Hazel; Sand, Letricia; Soh, Siew Yan; Wark, Jill

    2014-01-01

    Three-dimensional ultrasound (3DUS) at simulation compared to 3DUS at treatment is an image guidance option for partial breast irradiation (PBI). This study assessed if user dependence in acquiring and contouring 3DUS (operator variability) contributed to variation in seroma shifts calculated for breast IGRT. Eligible patients met breast criteria for current randomized PBI studies. 5 Operators participated in this study. For each patient, 3 operators were involved in scan acquisitions and 5 were involved in contouring. At CT simulation (CT1), a 3DUS (US1) was performed by a single radiation therapist (RT). 7 to 14 days after CT1 a second CT (CT2) and 3 sequential 3DUS scans (US2a,b,c) were acquired by each of 3 RTs. Seroma shifts, between US1 and US2 scans were calculated by comparing geometric centers of the seromas (centroids). Operator contouring variability was determined by comparing 5 RT’s contours for a single image set. Scanning variability was assessed by comparing shifts between multiple scans acquired at the same time point (US1-US2a,b,c). Shifts in seromas contoured on CT (CT1-CT2) were compared to US data. From an initial 28 patients, 15 had CT visible seromas, met PBI dosimetric constraints, had complete US data, and were analyzed. Operator variability contributed more to the overall variability in seroma localization than the variability associated with multiple scan acquisitions (95% confidence mean uncertainty of 6.2 mm vs. 1.1 mm). The mean standard deviation in seroma shift was user dependent and ranged from 1.7 to 2.9 mm. Mean seroma shifts from simulation to treatment were comparable to CT. Variability in shifts due to different users acquiring and contouring 3DUS for PBI guidance were comparable to CT shifts. Substantial inter-observer effect needs to be considered during clinical implementation of 3DUS IGRT

  9. FUN3D Manual: 13.3

    Science.gov (United States)

    Biedron, Robert T.; Carlson, Jan-Renee; Derlaga, Joseph M.; Gnoffo, Peter A.; Hammond, Dana P.; Jones, William T.; Kleb, Bil; Lee-Rausch, Elizabeth M.; Nielsen, Eric J.; Park, Michael A.; hide

    2018-01-01

    This manual describes the installation and execution of FUN3D version 13.3, including optional dependent packages. FUN3D is a suite of computational fluid dynamics simulation and design tools that uses mixed-element unstructured grids in a large number of formats, including structured multiblock and overset grid systems. A discretely-exact adjoint solver enables efficient gradient-based design and grid adaptation to reduce estimated discretization error. FUN3D is available with and without a reacting, real-gas capability. This generic gas option is available only for those persons that qualify for its beta release status.

  10. 3D deblending of simultaneous source data based on 3D multi-scale shaping operator

    Science.gov (United States)

    Zu, Shaohuan; Zhou, Hui; Mao, Weijian; Gong, Fei; Huang, Weilin

    2018-04-01

    We propose an iterative three-dimensional (3D) deblending scheme using 3D multi-scale shaping operator to separate 3D simultaneous source data. The proposed scheme is based on the property that signal is coherent, whereas interference is incoherent in some domains, e.g., common receiver domain and common midpoint domain. In two-dimensional (2D) blended record, the coherency difference of signal and interference is in only one spatial direction. Compared with 2D deblending, the 3D deblending can take more sparse constraints into consideration to obtain better performance, e.g., in 3D common receiver gather, the coherency difference is in two spatial directions. Furthermore, with different levels of coherency, signal and interference distribute in different scale curvelet domains. In both 2D and 3D blended records, most coherent signal locates in coarse scale curvelet domain, while most incoherent interference distributes in fine scale curvelet domain. The scale difference is larger in 3D deblending, thus, we apply the multi-scale shaping scheme to further improve the 3D deblending performance. We evaluate the performance of 3D and 2D deblending with the multi-scale and global shaping operators, respectively. One synthetic and one field data examples demonstrate the advantage of the 3D deblending with 3D multi-scale shaping operator.

  11. Underwater 3D filming

    Directory of Open Access Journals (Sweden)

    Roberto Rinaldi

    2014-12-01

    Full Text Available After an experimental phase of many years, 3D filming is now effective and successful. Improvements are still possible, but the film industry achieved memorable success on 3D movie’s box offices due to the overall quality of its products. Special environments such as space (“Gravity” and the underwater realm look perfect to be reproduced in 3D. “Filming in space” was possible in “Gravity” using special effects and computer graphic. The underwater realm is still difficult to be handled. Underwater filming in 3D was not that easy and effective as filming in 2D, since not long ago. After almost 3 years of research, a French, Austrian and Italian team realized a perfect tool to film underwater, in 3D, without any constrains. This allows filmmakers to bring the audience deep inside an environment where they most probably will never have the chance to be.

  12. 3D histomorphometric quantification from 3D computed tomography

    International Nuclear Information System (INIS)

    Oliveira, L.F. de; Lopes, R.T.

    2004-01-01

    The histomorphometric analysis is based on stereologic concepts and was originally applied to biologic samples. This technique has been used to evaluate different complex structures such as ceramic filters, net structures and cancellous objects that are objects with inner connected structures. The measured histomorphometric parameters of structure are: sample volume to total reconstructed volume (BV/TV), sample surface to sample volume (BS/BV), connection thickness (Tb Th ), connection number (Tb N ) and connection separation (Tb Sp ). The anisotropy was evaluated as well. These parameters constitute the base of histomorphometric analysis. The quantification is realized over cross-sections recovered by cone beam reconstruction, where a real-time microfocus radiographic system is used as tomographic system. The three-dimensional (3D) histomorphometry, obtained from tomography, corresponds to an evolution of conventional method that is based on 2D analysis. It is more coherent with morphologic and topologic context of the sample. This work shows result from 3D histomorphometric quantification to characterize objects examined by 3D computer tomography. The results, which characterizes the internal structures of ceramic foams with different porous density, are compared to results from conventional methods

  13. Scoops3D: software to analyze 3D slope stability throughout a digital landscape

    Science.gov (United States)

    Reid, Mark E.; Christian, Sarah B.; Brien, Dianne L.; Henderson, Scott T.

    2015-01-01

    The computer program, Scoops3D, evaluates slope stability throughout a digital landscape represented by a digital elevation model (DEM). The program uses a three-dimensional (3D) method of columns approach to assess the stability of many (typically millions) potential landslides within a user-defined size range. For each potential landslide (or failure), Scoops3D assesses the stability of a rotational, spherical slip surface encompassing many DEM cells using a 3D version of either Bishop’s simplified method or the Ordinary (Fellenius) method of limit-equilibrium analysis. Scoops3D has several options for the user to systematically and efficiently search throughout an entire DEM, thereby incorporating the effects of complex surface topography. In a thorough search, each DEM cell is included in multiple potential failures, and Scoops3D records the lowest stability (factor of safety) for each DEM cell, as well as the size (volume or area) associated with each of these potential landslides. It also determines the least-stable potential failure for the entire DEM. The user has a variety of options for building a 3D domain, including layers or full 3D distributions of strength and pore-water pressures, simplistic earthquake loading, and unsaturated suction conditions. Results from Scoops3D can be readily incorporated into a geographic information system (GIS) or other visualization software. This manual includes information on the theoretical basis for the slope-stability analysis, requirements for constructing and searching a 3D domain, a detailed operational guide (including step-by-step instructions for using the graphical user interface [GUI] software, Scoops3D-i) and input/output file specifications, practical considerations for conducting an analysis, results of verification tests, and multiple examples illustrating the capabilities of Scoops3D. Easy-to-use software installation packages are available for the Windows or Macintosh operating systems; these packages

  14. Percutaneous transluminal angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child after liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yussim, Ethan; Belenky, Alexander; Atar, Eli [Department of Diagnostic Radiology, Rabin Medical Center, Vascular and Interventional Radiology Unit, Petah Tikva (Israel); Shapiro, Rivka [Schneider Children' s Medical Center, Institute of Pediatric Gastroenterology and Nutrition, Petah Tikva (Israel); Mor, Eytan [Rabin Medical Center, Department of Organ Transplantation, Petah Tikva (Israel)

    2005-07-01

    Percutaneous transluminal angioplasty is increasingly used in children. We present a case of successful balloon angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child who underwent liver transplantation because of biliary atresia. Percutaneous reopening of the shunt is a relatively safe procedure that may spare patients of surgical intervention. (orig.)

  15. Percutaneous transluminal angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child after liver transplantation

    International Nuclear Information System (INIS)

    Yussim, Ethan; Belenky, Alexander; Atar, Eli; Shapiro, Rivka; Mor, Eytan

    2005-01-01

    Percutaneous transluminal angioplasty is increasingly used in children. We present a case of successful balloon angioplasty of an occluded surgical splenorenal shunt in a 4-year-old child who underwent liver transplantation because of biliary atresia. Percutaneous reopening of the shunt is a relatively safe procedure that may spare patients of surgical intervention. (orig.)

  16. Personalized 3D printed model of kidney and tumor anatomy: a useful tool for patient education.

    Science.gov (United States)

    Bernhard, Jean-Christophe; Isotani, Shuji; Matsugasumi, Toru; Duddalwar, Vinay; Hung, Andrew J; Suer, Evren; Baco, Eduard; Satkunasivam, Raj; Djaladat, Hooman; Metcalfe, Charles; Hu, Brian; Wong, Kelvin; Park, Daniel; Nguyen, Mike; Hwang, Darryl; Bazargani, Soroush T; de Castro Abreu, Andre Luis; Aron, Monish; Ukimura, Osamu; Gill, Inderbir S

    2016-03-01

    To assess the impact of 3D printed models of renal tumor on patient's understanding of their conditions. Patient understanding of their medical condition and treatment satisfaction has gained increasing attention in medicine. Novel technologies such as additive manufacturing [also termed three-dimensional (3D) printing] may play a role in patient education. A prospective pilot study was conducted, and seven patients with a primary diagnosis of kidney tumor who were being considered for partial nephrectomy were included after informed consent. All patients underwent four-phase multi-detector computerized tomography (MDCT) scanning from which renal volume data were extracted to create life-size patient-specific 3D printed models. Patient knowledge and understanding were evaluated before and after 3D model presentation. Patients' satisfaction with their specific 3D printed model was also assessed through a visual scale. After viewing their personal 3D kidney model, patients demonstrated an improvement in understanding of basic kidney physiology by 16.7 % (p = 0.018), kidney anatomy by 50 % (p = 0.026), tumor characteristics by 39.3 % (p = 0.068) and the planned surgical procedure by 44.6 % (p = 0.026). Presented herein is the initial clinical experience with 3D printing to facilitate patient's pre-surgical understanding of their kidney tumor and surgery.

  17. In vivo measurement of haloperidol affinity to dopamine D2/D3 receptors by [123I]IBZM and single photon emission computed tomography

    DEFF Research Database (Denmark)

    Videbaek, C; Toska, K; Friberg, L

    2001-01-01

    This study examines the feasibility of a steady-state bolus-integration method with the dopamine D2/D3 receptor single photon emission computer tomography (SPECT) tracer, [123I]IBZM, for determination of in vivo affinity of haloperidol. The nonspecific binding of [123I]IBZM was examined in the rat...... brain by infusion of haloperidol to plasma levels approximately 100 times the Kd level in man. In humans, Kd for haloperidol binding was measured in four healthy volunteers that were examined twice: once with partial dopamine D2/D3 receptor blockade obtained by a scheduled infusion of unlabeled...... haloperidol (0.7 mg total dosage), and once in an unblocked state. Blood sampling and SPECT were performed intermittently during 6 hours after intravenous [123I]IBZM bolus injection. Plasma [123I]IBZM was determined by octane extraction. Plasma haloperidol was determined by a radioimmunoassay, and plasma...

  18. MAP3D: a media processor approach for high-end 3D graphics

    Science.gov (United States)

    Darsa, Lucia; Stadnicki, Steven; Basoglu, Chris

    1999-12-01

    Equator Technologies, Inc. has used a software-first approach to produce several programmable and advanced VLIW processor architectures that have the flexibility to run both traditional systems tasks and an array of media-rich applications. For example, Equator's MAP1000A is the world's fastest single-chip programmable signal and image processor targeted for digital consumer and office automation markets. The Equator MAP3D is a proposal for the architecture of the next generation of the Equator MAP family. The MAP3D is designed to achieve high-end 3D performance and a variety of customizable special effects by combining special graphics features with high performance floating-point and media processor architecture. As a programmable media processor, it offers the advantages of a completely configurable 3D pipeline--allowing developers to experiment with different algorithms and to tailor their pipeline to achieve the highest performance for a particular application. With the support of Equator's advanced C compiler and toolkit, MAP3D programs can be written in a high-level language. This allows the compiler to successfully find and exploit any parallelism in a programmer's code, thus decreasing the time to market of a given applications. The ability to run an operating system makes it possible to run concurrent applications in the MAP3D chip, such as video decoding while executing the 3D pipelines, so that integration of applications is easily achieved--using real-time decoded imagery for texturing 3D objects, for instance. This novel architecture enables an affordable, integrated solution for high performance 3D graphics.

  19. The 3d84s and 3d84d configurations of the fourth spectrum of zinc: Zn IV

    International Nuclear Information System (INIS)

    Joshi, Y.N.; Van Kleef, T.A.M.

    1987-01-01

    The spectrum of zinc was photographed in the region 2000 A - 820 A on a 6.65 m and a 10.7 m normal incidence spectrograph using a sliding spark and a triggered spark source. The new measurements have helped us to confirm the earlier analysis of the 3d 8 4s-3d 8 4p transitions and locate the missing level 3d 8 4s 2 S 1/2 , and study the 3d 8 4p-3d 8 4d transitions. 59 out of 67 levels of the 3d 8 4d configuration have been established. Parametric least-squares-fitted calculations support the analysis. Two hundred and eight (208) additional lines have been classified in the Zn IV analysis. (orig.)

  20. Acquiring 3D scene information from 2D images

    NARCIS (Netherlands)

    Li, Ping

    2011-01-01

    In recent years, people are becoming increasingly acquainted with 3D technologies such as 3DTV, 3D movies and 3D virtual navigation of city environments in their daily life. Commercial 3D movies are now commonly available for consumers. Virtual navigation of our living environment as used on a

  1. Fabrication of lead-free piezoelectric Li2CO3-added (Ba,Ca)(Ti,Sn)O3 ceramics under controlled low oxygen partial pressure and their properties

    Science.gov (United States)

    Noritake, Kouta; Sakamoto, Wataru; Yuitoo, Isamu; Takeuchi, Teruaki; Hayashi, Koichiro; Yogo, Toshinobu

    2018-02-01

    Reduction-resistant lead-free (Ba,Ca)(Ti,Sn)O3 piezoceramics with high piezoelectric constants were fabricated by optimizing the amount of Li2CO3 added. Oxygen partial pressure was controlled during the sintering of (Ba,Ca)(Ti,Sn)O3 ceramics in a reducing atmosphere using H2-CO2 gas. Enhanced grain growth and a high-polarization state after poling treatment were achieved by adding Li2CO3. Optimizing the amount of Li2CO3 added to (Ba0.95Ca0.05)(Ti0.95Sn0.05)O3 ceramics sintered under a low oxygen partial pressure resulted in improved piezoelectric properties while maintaining the high sintered density. The prepared Li2CO3-added ceramic samples had homogeneous microstructures with a uniform dispersion of each major constituent element. However, the residual Li content in the 3 mol % Li2CO3-added (Ba0.95Ca0.05)(Ti0.95Sn0.05)O3 ceramics after sintering was less than 0.3 mol %. Sintered bodies of this ceramic prepared in a CO2 (1.5%)-H2 (0.3%)/Ar reducing atmosphere (PO2 = 10-8 atm at 1350 °C), exhibited sufficient electrical resistivity and a piezoelectric constant (d 33) exceeding 500 pC/N. The piezoelectric properties of this nonreducible ceramic were comparable or superior to those of the same ceramic sintered in air.

  2. 2D-Driven 3D Object Detection in RGB-D Images

    KAUST Repository

    Lahoud, Jean; Ghanem, Bernard

    2017-01-01

    In this paper, we present a technique that places 3D bounding boxes around objects in an RGB-D scene. Our approach makes best use of the 2D information to quickly reduce the search space in 3D, benefiting from state-of-the-art 2D object detection

  3. Minimal Blocking Sets in PG(2, 8) and Maximal Partial Spreads in PG(3, 8)

    DEFF Research Database (Denmark)

    Barat, Janos

    2004-01-01

    We prove that PG(2, 8) does not contain minimal blocking sets of size 14. Using this result we prove that 58 is the largest size for a maximal partial spread of PG(3, 8). This supports the conjecture that q2-q+ 2 is the largest size for a maximal partial spread of PG(3, q), q>7....

  4. Case report of newborn with de novo partial trisomy 2q31.2–37.3 ...

    Indian Academy of Sciences (India)

    Case report of newborn with de novo partial trisomy 2q31.2–37.3 and monosomy 9p24.3 ... This is the first report of molecular cytogenetic characterization of a partial trisomy 2q31.2–37.3 with monosomy 9p24.3. ... Manuscript received: 10 November 2016; Manuscript revised: 13 March 2017; Accepted: 21 March 2017 ...

  5. Partial wave analysis of KKPI system in D and E/IOTA region

    International Nuclear Information System (INIS)

    Chung, S.U.; Fernow, R.; Kirk, H.

    1985-01-01

    A partial wave analysis and a Dalitz plot analysis of high-statistics data from reaction π - p → K + K/sub S/π - n at 8.0 GeV/c show that the D(1285) is a J/sup PG/ = 1 ++ state and the E(1420) a J/sup PG/ = 0 -+ state both with a substantial deltaπ decay mode. The 1 ++ K*anti K wave exhibits a rapid rise near threshold but no evidence of a resonance in the E region. The assignment of J/sup PG/ = O -+ to the E is confirmed from a Dalitz-plot analysis of the reaction pp → K + K/sub S/π - X 0 . 11 refs., 5 figs

  6. Presynaptic Dopamine D2 Receptors Modulate [3H]GABA Release at StriatoPallidal Terminals via Activation of PLC → IP3 → Calcineurin and Inhibition of AC → cAMP → PKA Signaling Cascades.

    Science.gov (United States)

    Jijón-Lorenzo, Rafael; Caballero-Florán, Isaac Hiram; Recillas-Morales, Sergio; Cortés, Hernán; Avalos-Fuentes, José Arturo; Paz-Bermúdez, Francisco Javier; Erlij, David; Florán, Benjamín

    2018-02-21

    Striatal dopamine D2 receptors activate the PLC → IP3 → Calcineurin-signaling pathway to modulate the neural excitability of En+ Medium-sized Spiny GABAergic neurons (MSN) through the regulation of L-type Ca 2+ channels. Presynaptic dopaminergic D2 receptors modulate GABA release at striatopallidal terminals through L-type Ca 2+ channels as well, but their signaling pathway is still undetermined. Since D2 receptors are Gi/o-coupled and negatively modulate adenylyl cyclase (AC), we investigated whether presynaptic D2 receptors modulate GABA release through the same signaling cascade that controls excitability in the striatum or by the inhibition of AC and decreased PKA activity. Activation of D2 receptors stimulated formation of [ 3 H]IP 1 and decreased Forskolin-stimulated [ 3 H]cAMP accumulation in synaptosomes from rat Globus Pallidus. D2 receptor activation with Quinpirole in the presence of L 745,870 decreased, in a dose-dependent manner, K + -induced [ 3 H]GABA release in pallidal slices. The effect was prevented by the pharmacological blockade of Gi/o βγ subunit effects with Gallein, PLC with U 73122, IP3 receptor activation with 4-APB, Calcineurin with FK506. In addition, when release was stimulated with Forskolin to activate AC, D2 receptors also decreased K + -induced [ 3 H]GABA release, an effect occluded with the effect of the blockade of PKA with H89 or stimulation of release with the cAMP analog 8-Br-cAMP. These data indicate that D2 receptors modulate [ 3 H]GABA release at striatopallidal terminals by activating the PLC → IP3 → Calcineurin-signaling cascade, the same one that modulates excitability in soma. Additionally, D2 receptors inhibit release when AC is active. Both mechanisms appear to converge to regulate the activity of presynaptic L-type Ca 2+ channels. Copyright © 2018 IBRO. Published by Elsevier Ltd. All rights reserved.

  7. Transcatheter closure of patent ductus arteriosus and interruption of inferior vena cava with azygous continuation using an Amplatzer duct occluder II

    Directory of Open Access Journals (Sweden)

    Koh Ghee

    2009-01-01

    Full Text Available We report a case of transcatheter closure of patent ductus arteriosus using the new Amplatzer duct occluder II in an adult patient with interrupted inferior vena cava with azygous continuation via the femoral artery approach.

  8. 3D FaceCam: a fast and accurate 3D facial imaging device for biometrics applications

    Science.gov (United States)

    Geng, Jason; Zhuang, Ping; May, Patrick; Yi, Steven; Tunnell, David

    2004-08-01

    Human faces are fundamentally three-dimensional (3D) objects, and each face has its unique 3D geometric profile. The 3D geometric features of a human face can be used, together with its 2D texture, for rapid and accurate face recognition purposes. Due to the lack of low-cost and robust 3D sensors and effective 3D facial recognition (FR) algorithms, almost all existing FR systems use 2D face images. Genex has developed 3D solutions that overcome the inherent problems in 2D while also addressing limitations in other 3D alternatives. One important aspect of our solution is a unique 3D camera (the 3D FaceCam) that combines multiple imaging sensors within a single compact device to provide instantaneous, ear-to-ear coverage of a human face. This 3D camera uses three high-resolution CCD sensors and a color encoded pattern projection system. The RGB color information from each pixel is used to compute the range data and generate an accurate 3D surface map. The imaging system uses no moving parts and combines multiple 3D views to provide detailed and complete 3D coverage of the entire face. Images are captured within a fraction of a second and full-frame 3D data is produced within a few seconds. This described method provides much better data coverage and accuracy in feature areas with sharp features or details (such as the nose and eyes). Using this 3D data, we have been able to demonstrate that a 3D approach can significantly improve the performance of facial recognition. We have conducted tests in which we have varied the lighting conditions and angle of image acquisition in the "field." These tests have shown that the matching results are significantly improved when enrolling a 3D image rather than a single 2D image. With its 3D solutions, Genex is working toward unlocking the promise of powerful 3D FR and transferring FR from a lab technology into a real-world biometric solution.

  9. 3D-modeling and 3D-printing explorations on Japanese tea ceremony utensils

    NARCIS (Netherlands)

    Levy, P.D.; Yamada, Shigeru

    2017-01-01

    In this paper, we inquire aesthetical aspects of the Japanese tea ceremony, described as the aesthetics in the imperfection, based on novel fabrication technologies: 3D-modeling and 3D-printing. To do so, 3D-printed utensils (chashaku and chasen) were iteratively designed for the ceremony and were

  10. 3D printing for dummies

    CERN Document Server

    Hausman, Kalani Kirk

    2014-01-01

    Get started printing out 3D objects quickly and inexpensively! 3D printing is no longer just a figment of your imagination. This remarkable technology is coming to the masses with the growing availability of 3D printers. 3D printers create 3-dimensional layered models and they allow users to create prototypes that use multiple materials and colors.  This friendly-but-straightforward guide examines each type of 3D printing technology available today and gives artists, entrepreneurs, engineers, and hobbyists insight into the amazing things 3D printing has to offer. You'll discover methods for

  11. Kuvaus 3D-tulostamisesta hammastekniikassa

    OpenAIRE

    Munne, Mauri; Mustonen, Tuomas; Vähäjylkkä, Jaakko

    2013-01-01

    3D-tulostaminen kehittyy nopeasti ja yleistyy koko ajan. Tulostimien tarkkuuksien kehittyessä 3D-tulostus on ottamassa myös jalansijaa hammastekniikan alalta. Tämän opinnäytetyön tarkoituksena on kuvata 3D-tulostamisen tilaa hammastekniikassa. 3D-tulostaminen on Suomessa vielä melko harvinaista, joten opinnäytetyön tavoitteena on koota yhteen kaikki mahdollinen tieto liittyen 3D-tulostamiseen hammastekniikassa. Tavoitteena on myös 3D-tulostimen testaaminen käytännössä aina suun skannaami...

  12. New development in robot vision

    CERN Document Server

    Behal, Aman; Chung, Chi-Kit

    2015-01-01

    The field of robotic vision has advanced dramatically recently with the development of new range sensors.  Tremendous progress has been made resulting in significant impact on areas such as robotic navigation, scene/environment understanding, and visual learning. This edited book provides a solid and diversified reference source for some of the most recent important advancements in the field of robotic vision. The book starts with articles that describe new techniques to understand scenes from 2D/3D data such as estimation of planar structures, recognition of multiple objects in the scene using different kinds of features as well as their spatial and semantic relationships, generation of 3D object models, approach to recognize partially occluded objects, etc. Novel techniques are introduced to improve 3D perception accuracy with other sensors such as a gyroscope, positioning accuracy with a visual servoing based alignment strategy for microassembly, and increasing object recognition reliability using related...

  13. The dimension added by 3D scanning and 3D printing of meteorites

    Science.gov (United States)

    de Vet, S. J.

    2016-01-01

    An overview for the 3D photodocumentation of meteorites is presented, focussing on two 3D scanning methods in relation to 3D printing. The 3D photodocumention of meteorites provides new ways for the digital preservation of culturally, historically or scientifically unique meteorites. It has the potential for becoming a new documentation standard of meteorites that can exist complementary to traditional photographic documentation. Notable applications include (i.) use of physical properties in dark flight-, strewn field-, or aerodynamic modelling; (ii.) collection research of meteorites curated by different museum collections, and (iii.) public dissemination of meteorite models as a resource for educational users. The possible applications provided by the additional dimension of 3D illustrate the benefits for the meteoritics community.

  14. 3D Model Optimization of Four-Facet Drill for 3D Drilling Simulation

    Directory of Open Access Journals (Sweden)

    Buranský Ivan

    2016-09-01

    Full Text Available The article is focused on optimization of four-facet drill for 3D drilling numerical modelling. For optimization, the process of reverse engineering by PowerShape software was used. The design of four-facet drill was created in NumrotoPlus software. The modified 3D model of the drill was used in the numerical analysis of cutting forces. Verification of the accuracy of 3D models for reverse engineering was implemented using the colour deviation maps. The CAD model was in the STEP format. For simulation software, 3D model in the STEP format is ideal. STEP is a solid model. Simulation software automatically splits the 3D model into finite elements. The STEP model was therefore more suitable than the STL model.

  15. Signal alteration of the cochlear perilymph on 3 different sequences after intratympanic Gd-DTPA administration at 3 tesla. Comparison of 3D-FLAIR, 3D-T1-weighted imaging, and 3D-CISS

    International Nuclear Information System (INIS)

    Yamazaki, Masahiro; Naganawa, Shinji; Kawai, Hisashi; Nihashi, Takashi; Nakashima, Tsutomu

    2010-01-01

    Three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) imaging after intratympanic gadolinium injection is useful for pathophysiologic and morphologic analysis of the inner ear. However, statistical analysis of differences in inner ear signal intensity among 3D-FLAIR and other sequences has not been reported. We evaluated the signal intensity of cochlear fluid on each of 3D-FLAIR, 3D-T 1 -weighted imaging (T 1 WI), and 3D-constructive interference in the steady state (CISS) to clarify the differences in contrast effect among these 3 sequences using intratympanic gadolinium injection. Twenty-one patients underwent 3D-FLAIR, 3D-T 1 WI, and 3D-CISS imaging at 3 tesla 24 hours after intratympanic injection of gadolinium. We determined regions of interest of the cochleae (C) and medulla oblongata (M) on each image, evaluated the signal intensity ratio between C and M (CM ratio), and determined the ratio of cochlear signal intensity of the injected side to that of the non-injected side (contrast value). The CM ratio of the injected side (3.00±1.31, range, 0.53 to 4.88, on 3D-FLAIR; 0.83±0.30, range, 0.36 to 1.58 on 3D-T 1 WI) was significantly higher than that of the non-injected side (0.52±0.14, range, 0.30 to 0.76 on 3D-FLAIR; 0.49±0.11, range, 0.30 to 0.71 on 3D-T 1 WI) on 3D-FLAIR and 3D-T 1 WI (P 1 WI (1.73±0.60 range, 0.98 to 3.09) (P<0.001). The 3D-FLAIR sequence is the most sensitive for observing alteration in inner ear fluid signal after intratympanic gadolinium injection. Our results warrant use of 3D-FLAIR as a sensitive imaging technique to clarify the pathological and morphological mechanisms of disorders of the inner ear. (author)

  16. 25-Hydroxyvitamin D-3 affects vitamin D status similar to vitamin D-3 in pigs - but the meat produced has a lower content of vitamin D

    DEFF Research Database (Denmark)

    Jakobsen, Jette; Maribo, H.; Bysted, Anette

    2007-01-01

    In food databases, the specific contents of vitamin D-3 and 25-hydroxyvitamin D-3 in food have been implemented in the last 10 years. No consensus has yet been established on the relative activity between the components. Therefore, the objective of the present study was to assess the relative...... activity of 25-hydroxyvitamin D-3 compared to vitamin D-3. The design was a parallel study in pigs (n 24), which from an age of 12 weeks until slaughter 11 weeks later were fed approximately 55 mu g vitamin D/d, as vitamin D-3, in a mixture of vitamin D-3 and 25-hydroxyvitamin D-3, or 25-hydroxyvitamin D-3....... The end-points measured were plasma 25-hydroxyvitamin D-3, and in the liver and loin the content of vitamin D-3 and 25-hydroxyvitamin D-3 Vitamin D-3 and 25-hydroxyvitamin D3 in the feed did not affect 25-hydroxyvitamin D-3 in the plasma, liver or loin differently, while a significant effect was shown...

  17. In vivo analysis of the human superficial cerebral venous anatomy by using 3D-MRI

    International Nuclear Information System (INIS)

    Fujinaga, Yasunari

    1997-01-01

    The purpose of this study is to show the reliability of three dimensional magnetic resonance imaging (3D-MRI), and to classify the drainage patterns of the superficial cerebral veins. At first, toothpicks were stuck into fixed brain surface of a dog. To examine the best methods for making 3D-MRI, the 3D-MRI, including the diameter of the holes, of the dog's brain were analyzed in four threshold values. The holes on the 3D-MRI appeared smaller than their actual size due to the partial volume effect. The low threshold showed more errors than the higher. This result showed it was necessary to display the good 3D-MRI to refer the original MR images. Next, the 3D-MRI of clinical patients who had brain tumors were correlated with operative findings especially in relation to the lesions and brain surface, vessels, ventricles. The relation between the lesions and brain surface, vessels were displayed well, but there were some problems with inadequate ventricular display. Finally, anatomical study using 3D-MRI was performed, because 3D-MRI could display the relation between the brain surface and the superficial cerebral veins in the basic studies. The third study demonstrated that the transverse frontal vein was found in 15%, vein of Trolard ran in front of the central sulcus in 91.5% and several anastomosing veins were frequently observed. These studies showed the progress of technology in bringing about a lot of new information by using 3D-MRI. (author)

  18. 5-D interpolation with wave-front attributes

    Science.gov (United States)

    Xie, Yujiang; Gajewski, Dirk

    2017-11-01

    Most 5-D interpolation and regularization techniques reconstruct the missing data in the frequency domain by using mathematical transforms. An alternative type of interpolation methods uses wave-front attributes, that is, quantities with a specific physical meaning like the angle of emergence and wave-front curvatures. In these attributes structural information of subsurface features like dip and strike of a reflector are included. These wave-front attributes work on 5-D data space (e.g. common-midpoint coordinates in x and y, offset, azimuth and time), leading to a 5-D interpolation technique. Since the process is based on stacking next to the interpolation a pre-stack data enhancement is achieved, improving the signal-to-noise ratio (S/N) of interpolated and recorded traces. The wave-front attributes are determined in a data-driven fashion, for example, with the Common Reflection Surface (CRS method). As one of the wave-front-attribute-based interpolation techniques, the 3-D partial CRS method was proposed to enhance the quality of 3-D pre-stack data with low S/N. In the past work on 3-D partial stacks, two potential problems were still unsolved. For high-quality wave-front attributes, we suggest a global optimization strategy instead of the so far used pragmatic search approach. In previous works, the interpolation of 3-D data was performed along a specific azimuth which is acceptable for narrow azimuth acquisition but does not exploit the potential of wide-, rich- or full-azimuth acquisitions. The conventional 3-D partial CRS method is improved in this work and we call it as a wave-front-attribute-based 5-D interpolation (5-D WABI) as the two problems mentioned above are addressed. Data examples demonstrate the improved performance by the 5-D WABI method when compared with the conventional 3-D partial CRS approach. A comparison of the rank-reduction-based 5-D seismic interpolation technique with the proposed 5-D WABI method is given. The comparison reveals that

  19. Dopamine D2 receptor radiotracers [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride are indistinguishably inhibited by D2 agonists and antagonists ex vivo

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, Patrick N. [Institute of Medical Science, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada)], E-mail: patrick.mccormick@camhpet.ca; Kapur, Shitij [Department of Psychiatry, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada); PET Center, Center for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Seeman, Philip [Department of Psychiatry, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada); Department of Pharmacology, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada); Wilson, Alan A. [Department of Psychiatry, University of Toronto, Toronto, Ontario, M5S 1A8 (Canada); PET Center, Center for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada)

    2008-01-15

    Introduction: In vitro, the dopamine D2 receptor exists in two states, with high and low affinity for agonists. The high-affinity state is the physiologically active state thought to be involved in dopaminergic illnesses such as schizophrenia. The positron emission tomography radiotracer [{sup 11}C](+)-PHNO ([{sup 11}C](+)-4-propyl-3,4,4a,5,6,10b-hexahydro-2H-naphtho[1,2-b][1,4] oxazin-9-o l), being a D2 agonist, should selectively label the high-affinity state at tracer dose and therefore be more susceptible to competition by agonist as compared to the antagonist [{sup 3}H]raclopride, which binds to both affinity states. Methods: We tested this prediction using ex vivo dual-radiotracer experiments in conscious rats. D2 antagonists (haloperidol or clozapine), a partial agonist (aripiprazole), a full agonist [(-)-NPA] or the dopamine-releasing drug amphetamine (AMPH) were administered to rats prior to an intravenous coinjection of [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride. Rats were sacrificed 60 min after radiotracer injection. Striatum, cerebellum and plasma samples were counted for {sup 11}C and {sup 3}H. The specific binding ratio {l_brace}SBR, i.e., [%ID/g (striatum)-%ID/g (cerebellum)]/(%ID/g (cerebellum){r_brace} was used as the outcome measure. Results: In response to D2 antagonists, partial agonist or full agonist, [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride SBRs responded indistinguishably in terms of both ED{sub 50} and Hill slope (e.g., (-)-NPA ED{sub 50} values are 0.027 and 0.023 mg/kg for [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride, respectively). In response to AMPH challenge, [{sup 11}C](+)-PHNO and [{sup 3}H]raclopride SBRs were inhibited to the same degree. Conclusions: We have shown that the SBRs of [{sup 11}C](+)-PHNO- and [{sup 3}H]raclopride do not differ in their response to agonist challenge. These results do not support predictions of the in vivo binding behavior of a D2 agonist radiotracer and cast some doubt on the in vivo

  20. Biophysical force regulation in 3D tumor cell invasion

    Science.gov (United States)

    Wu, Mingming

    When embedded within 3D extracellular matrices (ECM), animal cells constantly probe and adapt to the ECM locally (at cell length scale) and exert forces and communicate with other cells globally (up to 10 times of cell length). It is now well accepted that mechanical crosstalk between animal cells and their microenvironment critically regulate cell function such as migration, proliferation and differentiation. Disruption of the cell-ECM crosstalk is implicated in a number of pathologic processes including tumor progression and fibrosis. Central to the problem of cell-ECM crosstalk is the physical force that cells generate. By measuring single cell generated force within 3D collagen matrices, we revealed a mechanical crosstalk mechanism between the tumor cells and the ECM. Cells generate sufficient force to stiffen collagen fiber network, and stiffer matrix, in return promotes larger cell force generation. Our work highlights the importance of fibrous nonlinear elasticity in regulating tumor cell-ECM interaction, and results may have implications in the rapid tissue stiffening commonly found in tumor progression and fibrosis. This work is partially supported by NIH Grants R21RR025801 and R21GM103388.

  1. Development of 3-D FBR heterogeneous core calculation method based on characteristics method

    International Nuclear Information System (INIS)

    Takeda, Toshikazu; Maruyama, Manabu; Hamada, Yuzuru; Nishi, Hiroshi; Ishibashi, Junichi; Kitano, Akihiro

    2002-01-01

    A new 3-D transport calculation method taking into account the heterogeneity of fuel assemblies has been developed by combining the characteristics method and the nodal transport method. In the axial direction the nodal transport method is applied, and the characteristics method is applied to take into account the radial heterogeneity of fuel assemblies. The numerical calculations have been performed to verify 2-D radial calculations of FBR assemblies and partial core calculations. Results are compared with the reference Monte-Carlo calculations. A good agreement has been achieved. It is shown that the present method has an advantage in calculating reaction rates in a small region

  2. 3D digital anatomy modelling - Practical or pretty?

    Science.gov (United States)

    Murgitroyd, Ellen; Madurska, Marta; Gonzalez, Jasmina; Watson, Angus

    2015-06-01

    With an increasing move towards digitalisation of medical records and medical teaching, such as online exams and webinars, one of the questions that persists asks 'is there a place for digital anatomy teaching and can it effectively replace the traditional teaching methods such as cadaveric dissection?' Cadaveric dissection has a number of benefits as a teaching method but it also has its limitations. Although these can be partially addressed by prosections and new more "life-like" fixatives, it does not address the lack of resources and the increasing pressure to be able to study and learn at home. This paper reviews the literature with regards to the suitability of digital models for teaching and the wider uses a 3D digital anatomy model could have, such as postgraduate teaching, patient education and surgical planning. It also looks briefly at the learning model that anatomy as art contributes. The literature has scattered examples of digital models used for teaching at both undergraduate and postgraduate level, which demonstrate a number of positive outcomes, mostly surrounding user satisfaction and convenience. 3D modelling for patient education and operation planning has less exploration, and these papers generate a number of discussion points, mostly surrounding the practicality of digital models, which can be more time consuming and require the technology to be widely available and reliable. 3D digital anatomy is a useful adjunct to teaching and its use in patient education and operation planning have interesting possibilities still to be fully explored. Copyright © 2014 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  3. The 3d4-3d34p transitions of triply ionized manganese (Mn IV)

    International Nuclear Information System (INIS)

    Tchang-Brillet, W.Ue.L.; Artru, M.C.; Wyart, J.F.

    1986-01-01

    The analysis of Mn IV is extended in the wavelength range 473-847 A. A total of 600 classified lines are given, of which 372 are newly observed. All of them are due to 3d 4 -3d 3 4p transitions. Their classification and the identification of 59 new levels are supported by the parametric studies of the 3d 4 and 3d 3 4p configurations. The ground configuration 3d 4 is calculated by taking into account the effective magnetic interactions which improve by an order of magnitude the theoretical fine structure of the quintet and triplet terms. The analysis was guided by the prediction of relative line strengths in intermediate coupling. Calculated energies and LS composition are given for all levels of the configuration, 3d 4 and 3d 3 4p. (orig).

  4. 3D-MR vs. 3D-CT of the shoulder in patients with glenohumeral instability

    Energy Technology Data Exchange (ETDEWEB)

    Stillwater, Laurence; Koenig, James; Maycher, Bruce; Davidson, Michael [University of Manitoba, Winnipeg (Canada)

    2017-03-15

    To determine whether 3D-MR osseous reformats of the shoulder are equivalent to 3D-CT osseous reformats in patients with glenohumeral instability. Patients with glenohumeral instability, who were to be imaged with both CT and MRI, were prospectively selected. CT and MR were performed within 24 h of one another on 12 shoulders. Each MR study included an axial 3D isotropic VIBE sequence. The image data from the isotropic VIBE sequence were post-processed using subtraction and 3D software. CT data were post-processed using 3D software. The following measurements were obtained for both 3D-CT and 3D-MR post-processed images: height and width of the humeral head and glenoid, Hill-Sachs size and percent humeral head loss (if present), size of glenoid bone loss and percent glenoid bone loss (if present). Paired t-tests and two one-sided tests for equivalence were used to assess the differences between imaging modalities and equivalence. The measurement differences from the 3D-CT and 3D-MR post-processed images were not statistically significant. The measurement differences for humeral height, glenoid height and glenoid width were borderline statistically significant; however, using any adjustment for multiple comparisons, this failed to be significant. Using an equivalence margin of 1 mm for measurements and 1.5% for percent bone loss, the 3D-MR and 3D-CT post-processed images were equivalent. Three-dimensional-MR osseous models of the shoulder using a 3D isotropic VIBE sequence were equivalent to 3D-CT osseous models, and the differences between modalities were not statistically significant. (orig.)

  5. 3D geometric phase analysis and its application in 3D microscopic morphology measurement

    Science.gov (United States)

    Zhu, Ronghua; Shi, Wenxiong; Cao, Quankun; Liu, Zhanwei; Guo, Baoqiao; Xie, Huimin

    2018-04-01

    Although three-dimensional (3D) morphology measurement has been widely applied on the macro-scale, there is still a lack of 3D measurement technology on the microscopic scale. In this paper, a microscopic 3D measurement technique based on the 3D-geometric phase analysis (GPA) method is proposed. In this method, with machine vision and phase matching, the traditional GPA method is extended to three dimensions. Using this method, 3D deformation measurement on the micro-scale can be realized using a light microscope. Simulation experiments were conducted in this study, and the results demonstrate that the proposed method has a good anti-noise ability. In addition, the 3D morphology of the necking zone in a tensile specimen was measured, and the results demonstrate that this method is feasible.

  6. 2D/3D/4D ULTRASOUND IN INFERTILITY MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Uršula Reš-Muravec

    2018-02-01

    Ultrasound in infertility diagnostics: Ultrasound is used for examination of uterus, tubes, ovaries and peritoneal cause of infertility. It can be used in different menstrual phases: proliferative, periovulatory and secretory phase. Examination of uterus: A 2D scan can measure the size of the uterus (length, width and depth and a 2D flow (colour and power doppler. With 3D technology we can measure the whole volume with VOCAL (virtual organ computer-aided analysis and 3D circulation with the index (VI – vascular index, FI – flow index and VFI – vascular flow index in the uterus. A 2D scan can help us define uterine malformations, fibroids and adenomyosis to a certain extent. However, a 3D scan offers more accurate diagnosis of these malformations. Endometrium is examined separately. With 2D the width is measured and morphology and focal lesions (polyp, fibroids, adhesions are examined. With 3D the real sagital plane for the width measurement can be defined . We can measure the volume of endometrium and subendometrium and 3D circulation in endometrium and subendometrium. The FIS (f luid instlation sonography is very useful when examining the endometrium; saline or gel can be used for uterine instalation. We can measure and define the position of the structures in the endometrium more accurately when they are surrouned by saline or gel. We can view these structures with a surface view, similar to the one used for hysteroscopy. With this information we can explain the pathology to the patient and easily plan the surgical procedures. Examination of the tubes: With 2D US we can see the tubes in the pelvis only if there are dilatations, but sometimes it is difficult to distinguish them from the neighbouring forma- tions. With a 3D ultrasound we can define the shape and continuity of the tube and we can view the tube from different angles (inversion mode. Different contrast media are used for determining tubal patency. Tubal patency can be diagnosed with 2D Hy

  7. SALE-3D, 3-D Fluid Flow, Navier Stokes Equation Using Lagrangian or Eulerian Method

    International Nuclear Information System (INIS)

    Amsden, A.A.; Ruppel, H.M.

    1991-01-01

    1 - Description of problem or function: SALE-3D calculates three- dimensional fluid flows at all speeds, from the incompressible limit to highly supersonic. An implicit treatment of the pressure calculation similar to that in the Implicit Continuous-fluid Eulerian (ICE) technique provides this flow speed flexibility. In addition, the computing mesh may move with the fluid in a typical Lagrangian fashion, be held fixed in an Eulerian manner, or move in some arbitrarily specified way to provide a continuous rezoning capability. This latitude results from use of an Arbitrary Lagrangian-Eulerian (ALE) treatment of the mesh. The partial differential equations solved are the Navier-Stokes equations and the mass and internal energy equations. The fluid pressure is determined from an equation of state and supplemented with an artificial viscous pressure for the computation of shock waves. The computing mesh consists of a three-dimensional network of arbitrarily shaped, six-sided deformable cells, and a variety of user-selectable boundary conditions are provided in the program. 2 - Method of solution: SALE3D uses an ICED-ALE technique, which combines the ICE method of treating flow speeds and the ALE mesh treatment to calculate three-dimensional fluid flow. The finite- difference approximations to the conservation of mass, momentum, and specific internal energy differential equations are solved in a sequence of time steps on a network of deformable computational cells. The basic hydrodynamic part of each cycle is divided into three phases: (1) an explicit solution of the Lagrangian equations of motion updating the velocity field by the effects of all forces, (2) an implicit calculation using Newton-Raphson iterative scheme that provides time-advanced pressures and velocities, and (3) the addition of advective contributions for runs that are Eulerian or contain some relative motion of grid and fluid. A powerful feature of this three-phases approach is the ease with which

  8. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    Science.gov (United States)

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure

  9. Effect of radiotherapy on experimental liver regenerative capacities following partial hepatectomy in rats

    International Nuclear Information System (INIS)

    Du Shisuo; Zeng Zhaochong; Tang Zhaoyou; Zhang Zhenyu; Wu Zheng; Shi Liusheng

    2008-01-01

    Objective: To investigate the regenerative capacities and proliferation related cytokines expression of normal and irradiated livers following 70% partial hepatectomy in rats. Methods: 90 male Sprague-Dawley rats were divided into 3 groups. The control group was only received 70% partial hepatectomy. The two irradiated groups were performed a single dose of 4 Gy and 8 Gy photon irradiation respectively followed 70% partial hepatectomy. The remanent liver were excised at 0.5,1.0,2.0,3.0,7.0 and 10.0 d after hepatectomy, and liver regeneration capacities in normal and irradiated rats were evaluated through remanent liver weigh, BrdU incorporation, PCNA labeling, and mitotic indices. The proliferation related cytokines expression were also compared. Results: After radiotherapy and hepatectomy 1 rats died of infection in control group, and two rats in 8 Gy group died of radiation induced enteritis. The original liver weigh is regained within 12 days in control and 4 Gy group, and proliferative speed was lower in 4 Gy group than control group. The weigh of remanent liver in 8 Gy group was significantly lower than the two groups all time points from 2d. The apex of PCNA labeling index was 80.2 ± 7.6%, 71.2 ± 6.5% and 55.3 ± 4.7% in control, 4 Gy and 8 Gy groups respectively at 2d, and 44.2 ± 5.4%, 35.3 ± 5.72% and 5.3 ± 6.9% with BrdU incorporation index. HGF mRNA expression peak of 4 Gy group was significantly lower than in control at 1 d, but no apparent peak value in 8 Gy group. TGF-β1 and TGF-β RII level of radiation groups was apparently higher than the control group at different time points. Meanwhile the p53 protein tend to increase at 1 d then decline with high expression in irradiated groups. Conclusion: Whole radiation can significantly inhibit the regenerative capacities following partial hepatectomy in rats with dose dependent. (authors)

  10. TLS-Based Feature Extraction and 3D Modeling for Arch Structures

    Directory of Open Access Journals (Sweden)

    Xiangyang Xu

    2017-01-01

    Full Text Available Terrestrial laser scanning (TLS technology is one of the most efficient and accurate tools for 3D measurement which can reveal surface-based characteristics of objects with the aid of computer vision and programming. Thus, it plays an increasingly important role in deformation monitoring and analysis. Automatic data extraction and high efficiency and accuracy modeling from scattered point clouds are challenging issues during the TLS data processing. This paper presents a data extraction method considering the partial and statistical distribution of the point clouds scanned, called the window-neighborhood method. Based on the point clouds extracted, 3D modeling of the boundary of an arched structure was carried out. The ideal modeling strategy should be fast, accurate, and less complex regarding its application to large amounts of data. The paper discusses the accuracy of fittings in four cases between whole curve, segmentation, polynomial, and B-spline. A similar number of parameters was set for polynomial and B-spline because the number of unknown parameters is essential for the accuracy of the fittings. The uncertainties of the scanned raw point clouds and the modeling are discussed. This process is considered a prerequisite step for 3D deformation analysis with TLS.

  11. Effects of Acute and Chronic Treatments with Dopamine D2 and D3 Receptor Ligands on Cocaine versus Food Choice in Rats.

    Science.gov (United States)

    Thomsen, Morgane; Barrett, Andrew C; Butler, Paul; Negus, S Stevens; Caine, S Barak

    2017-07-01

    Dopamine D 3 receptor ligands are potential medications for psychostimulant addiction. Medication assessment may benefit from preclinical studies that evaluate chronic medication effects on choice between an abused drug and an alternative, nondrug reinforcer. This study compared acute and chronic effects of dopamine D 2 - and D 3 -preferring ligands on choice between intravenous cocaine and palatable food in rats. Under baseline conditions, cocaine maintained dose-dependent increases in cocaine choice and reciprocal decreases in food choice. Acutely, the D 2 agonist R -(-)-norpropylapomorphine (NPA) and antagonist L-741,626 [3-[[4-(4-chlorophenyl)-4-hydroxypiperidin-l-yl]methyl-1 H -indole] produced leftward and rightward shifts in cocaine dose-effect curves, respectively, whereas the partial agonist terguride had no effect. All three drugs dose-dependently decreased food-maintained responding. Chronically, the effects of R -(-)-norpropylapomorphine and L-741,626 on cocaine self-administration showed marked tolerance, whereas suppression of food-reinforced behavior persisted. Acute effects of the D 3 ligands were less systematic and most consistent with nonselective decreases in cocaine- and food-maintained responding. Chronically, the D 3 agonist PF-592,379 [5-[(2 R ,5 S )-5-methyl-4-propylmorpholin-2-yl]pyridin-2-amine] increased cocaine choice, whereas an intermediate dose of the D 3 antagonist PG01037 [ N -[( E )-4-[4-(2,3-dichlorophenyl)piperazin-1-yl]but-2-enyl]-4-pyridin-2-ylbenzamide] produced a therapeutically desirable decrease in cocaine choice early in treatment; however, tolerance to this effect developed, and lower and higher doses were ineffective. D 3 ligands failed to significantly modify total cocaine intake but caused persistent decreases in food intake. Thus, D 2 -and D 3 -preferring ligands showed distinct profiles, consistent with different pharmacological actions. In addition, these results highlight the role of acute versus chronic treatment

  12. Development of parallel 3D discrete ordinates transport program on JASMIN framework

    International Nuclear Information System (INIS)

    Cheng, T.; Wei, J.; Shen, H.; Zhong, B.; Deng, L.

    2015-01-01

    A parallel 3D discrete ordinates radiation transport code JSNT-S is developed, aiming at simulating real-world radiation shielding and reactor physics applications in a reasonable time. Through the patch-based domain partition algorithm, the memory requirement is shared among processors and a space-angle parallel sweeping algorithm is developed based on data-driven algorithm. Acceleration methods such as partial current rebalance are implemented. The correctness is proved through the VENUS-3 and other benchmark models. In the radiation shielding calculation of the Qinshan-II reactor pressure vessel model with 24.3 billion DoF, only 88 seconds is required and the overall parallel efficiency of 44% is achieved on 1536 CPU cores. (author)

  13. Carotid endarterectomy in cervical block anesthesia in patients with occluded contralateral internal carotid artery

    Directory of Open Access Journals (Sweden)

    Ilijevski Nenad

    2006-01-01

    Full Text Available Introduction: The goal of modern carotid surgery is relief of symptoms, stroke prevention, improvement in quality of life, prevention of vascular dementia, and prolongation of lifetime. OBJECTIVE: The objective of this paper was to compare the outcome of carotid endarterectomy in cervical block vs. general anesthesia in patients with occluded contralateral internal carotid artery (ICA. METHOD: One hundred patients (76 male, 24 female, mean age 60.81 years with occluded contralateral ICA were operated from 1997-2000. Neurological symptomatology, deficiency and stroke incidence were preoperatively analyzed in two groups. Duplex-scanning, angiograms and CT-scan confirmed the diagnosis. Risk factors analysis included hypertension, diabetes, lipid metabolism disorders, smoking and history of CAD, CABG and PAOD. Morbidity and mortality were used to compare the outcome of surgery in two groups. RESULTS There was no difference of age, gender and symptomatology between the groups. Paresis, TIA and dysphasia were most frequent. 70%-90% of ICA stenosis was seen in the majority of patients. Hypertension and smoking were dominant risk factors in these two groups. Eversion carotid end arterectomy was the most frequent technique used. In three cases out of nine that were operated under cervical block, the neurological symptoms developed just after clamping, so the intra-luminal shunt was placed. Postoperative morbidity was 12% and mortality was 8%. Conclusion: There was no difference of preoperative parameters, surgical technique and outcome in these two groups. Without other intraoperative monitoring, cervical block anesthesia might be an option in patients with the occlusion of the contralateral ICA. However, prospective studies involving more patients are needed.

  14. 3D-grafiikka ja pelimoottorit

    OpenAIRE

    Sillanpää, Otto

    2014-01-01

    Tässä opinnäytetyössä tutkitaan miten 3D-mallit saadaan sellaiseen muotoon, että ne olisivat käytettävissä eri pelimoottoreissa. Tutkimuksen tarkoituksena on selvittää, miten luodaan 3D-malleja pelimoottoreihin, sekä miten 3D-mallinnusohjelmat ja pelimoottorit eroavat toisistaan, kun käsitellään 3D-malleja. Tässä työssä pelimoottoreina toimivat Valven Source sekä Epic Gamesin Unreal Engine 3. 3D-mallinnusohjelmista käytössä olivat Autodeskin 3ds Max 2014 ja Blender Foundationin Blender 2.7...

  15. Reactive flow simulation in complex 3D geometries using the COM3D code

    International Nuclear Information System (INIS)

    Breitung, W.; Kotchourko, A.; Veser, A.; Scholtyssek, W.

    1999-01-01

    The COM3D code, under development at the Forschungszentrum Karlsruhe (FZK), is a 3-d CFD code to describe turbulent combustion phenomena in complex geometries. It is intended to be part of the advanced integral code system for containment analysis (INCA) which includes in addition GASFLOW for distribution calculations, V3D for slow combustion and DET3D for detonation analysis. COM3D uses a TVD-solver and optional models for turbulence, chemistry and thermodynamics. The hydrodynamic model considers mass, momentum and energy conservation. Advanced procedures were provided to facilitate grid-development for complex 3-d structures. COM3D was validated on experiments performed on different scales with generally good agreement for important physical quantities. The code was applied to combustion analysis of a large PWR. The initial conditions were obtained from a GASFLOW distribution analysis for a LOOP scenario. Results are presented concerning flame propagation and pressure evolution in the containment which clearly demonstrate the effects of internal structures, their influence on turbulence formation and consequences for local loads. (author)

  16. Characterisation of 5-HT3C, 5-HT3D and 5-HT3E receptor subunits: evolution, distribution and function.

    Science.gov (United States)

    Holbrook, Joanna D; Gill, Catherine H; Zebda, Noureddine; Spencer, Jon P; Leyland, Rebecca; Rance, Kim H; Trinh, Han; Balmer, Gemma; Kelly, Fiona M; Yusaf, Shahnaz P; Courtenay, Nicola; Luck, Jane; Rhodes, Andrew; Modha, Sundip; Moore, Stephen E; Sanger, Gareth J; Gunthorpe, Martin J

    2009-01-01

    The 5-HT(3) receptor is a member of the 'Cys-loop' family of ligand-gated ion channels that mediate fast excitatory and inhibitory transmission in the nervous system. Current evidence points towards native 5-HT(3) receptors originating from homomeric assemblies of 5-HT(3A) or heteromeric assembly of 5-HT(3A) and 5-HT(3B). Novel genes encoding 5-HT(3C), 5-HT(3D), and 5-HT(3E) have recently been described but the functional importance of these proteins is unknown. In the present study, in silico analysis (confirmed by partial cloning) indicated that 5-HT(3C), 5-HT(3D), and 5-HT(3E) are not human-specific as previously reported: they are conserved in multiple mammalian species but are absent in rodents. Expression profiles of the novel human genes indicated high levels in the gastrointestinal tract but also in the brain, Dorsal Root Ganglion (DRG) and other tissues. Following the demonstration that these subunits are expressed at the cell membrane, the functional properties of the recombinant human subunits were investigated using patch clamp electrophysiology. 5-HT(3C), 5-HT(3D), and 5-HT(3E) were all non-functional when expressed alone. Co-transfection studies to determine potential novel heteromeric receptor interactions with 5-HT(3A) demonstrated that the expression or function of the receptor was modified by 5-HT(3C) and 5-HT(3E), but not 5-HT(3D). The lack of distinct effects on current rectification, kinetics or pharmacology of 5-HT(3A) receptors does not however provide unequivocal evidence to support a direct contribution of 5-HT(3C) or 5-HT(3E) to the lining of the ion channel pore of novel heteromeric receptors. The functional and pharmacological contributions of these novel subunits to human biology and diseases such as irritable bowel syndrome for which 5-HT(3) receptor antagonists have major clinical usage, therefore remains to be fully determined.

  17. 3D Hilbert Space Filling Curves in 3D City Modeling for Faster Spatial Queries

    DEFF Research Database (Denmark)

    Ujang, Uznir; Antón Castro, Francesc/François; Azri, Suhaibah

    2014-01-01

    The advantages of three dimensional (3D) city models can be seen in various applications including photogrammetry, urban and regional planning, computer games, etc. They expand the visualization and analysis capabilities of Geographic Information Systems on cities, and they can be developed using...... method, retrieving portions of and especially searching these 3D city models, will not be done optimally. Even though current developments are based on an open data model allotted by the Open Geospatial Consortium (OGC) called CityGML, its XML-based structure makes it challenging to cluster the 3D urban...... objects. In this research, the authors propose an opponent data constellation technique of space-filling curves (3D Hilbert curves) for 3D city model data representation. Unlike previous methods, that try to project 3D or n-dimensional data down to 2D or 3D using Principal Component Analysis (PCA...

  18. Synthesis of cefepime-d3 and cefepime-d8

    International Nuclear Information System (INIS)

    Kamachi, Hajime; Okita, Takaaki; Tsuno, Takashi; Naito, Takayuki

    1990-01-01

    Synthesis of cefepime-d 3 (6a) and cefepime-d 8 (6b) is described. Diphenylmethyl 7-benzylideneamino-3-chloromethyl-3-cephem-4-carboxylate (2) was treated with sodium iodide to afford the iodide 3, which was without isolation, allowed to react with N-methyl-d 3 -pyrrolidine to give the quaternary salt 4a. Deblocking of 4a with HCO 2 H and HCl gave 7-amino-3-(N-methyl-d3-pyrrolidinio)methyl-3-cephem-4-carboxylate hydrochloride (5a). Acylation of 5a with benzotriazol-1-yl (Z)-2-(2-aminothiazol-4-yl)-2-methoxyiminoacetate followed by treatment with dil. H 2 SO 4 afforded 6a sulfate. In the same way, 6b was synthesized using N-methyl-pyrrolidine-d 8 . (author)

  19. Using one hybrid 3D-1D-3D approach for the conceptual design of WCCB blanket for CFETR

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Kecheng; Zhang, Xiaokang [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); University of Science and Technology of China, Hefei, Anhui, 230027 (China); Li, Jia [University of Science and Technology of China, Hefei, Anhui, 230027 (China); Ma, Xuebin [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); University of Science and Technology of China, Hefei, Anhui, 230027 (China); Liu, Songlin, E-mail: slliu@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui, 230031 (China); University of Science and Technology of China, Hefei, Anhui, 230027 (China)

    2017-01-15

    Highlights: • The Hybrid 3D-1D-3D approach is used for radial building design of WCCB. • Nuclear heat obtained by this method agrees well with 3D neutronics results. • The final results of temperature and TBR satisfy with the requirements. • All the results show that this approach is high efficiency and high reliability. - Abstract: A hybrid 3D-1D-3D approach is proposed for the conceptual design of a blanket. Firstly, the neutron wall loading (NWL) of each blanket module is obtained through a neutronics calculation employing a 3D model, which contains the geometry outline of in-vacuum vessel components and the exact neutron source distribution. Secondly, a 1D cylindrical model with the blanket module containing a detailed radial building is adopted for the neutronics analysis, with the aim of calculating the tritium breeding ratio (TBR) and nuclear heating. Being normalized to the NWL, the nuclear heating is transferred to a 2D model for thermal-hydraulics analysis using the FLUENT code. Through a series analysis of nuclear-thermal iterations that considers the tritium breeding ratio (TBR) and thermal performance as optimization objectives, the optimized radial building of each module surrounding plasma can be obtained. Thirdly, the 3D structural design of each module is established by adding side walls, cover plates, stiffening plates, and other components based on the radial building. The 3D neutronics and thermal-hydraulics using the detailed blanket modules are re-analyzed. This approach has been successfully applied to the design of a water-cooled ceramic breeder blanket for the Chinese Fusion Engineering Test Reactor (CFETR). The radial building of each blanket module surrounding plasma is optimized. The global tritium breeding ratio (TBR) calculated by the 3D neutronics analysis is 1.21, and the temperature of all materials in the 3D blanket structure is below the upper limits. As indicated by the comparison of the 1D and 3D neutronics and thermal

  20. Modelling 3D spatial objects in a geo-DBMS using a 3D primitive

    Science.gov (United States)

    Arens, Călin; Stoter, Jantien; van Oosterom, Peter

    2005-03-01

    There is a growing interest in modelling the world in three dimensions, both in applications and in science. At the same time, geographical information systems are changing into integrated architecture in which administrative and spatial data are maintained in one environment. It is for this reason that mainstream Data Base Management Systems (DBMSs) have implemented spatial data types according to the 'Simple Feature Specifications for SQL', described by the OpenGeospatial Consortium. However, these specifications are 2D, as indeed are the implementations in DBMSs. At the Section GIS Technology of TU Delft, research has been carried out in which a 3D primitive was implemented in a DBMS (Oracle Spatial). To explore the possibilities and complications, a fairly simple 3D primitive was chosen to start with: a polyhedron. In the future the study will be extended with more complex primitives, the ultimate aim being to build 3D models with features closer to the real world. Besides the data structure, a validation function was developed to check the geometric accuracy of the data. Rules for validation were established and translated into prototype implementations with the aid of literature. In order to manipulate the data, a list of useful 3D functions was specified. Most of these were translated into algorithms, which were implemented in the DBMS. The algorithms for these functions were obtained from the relevant literature. The research also comprised a comparative performance test on spatial indexing in 2D and 3D, using an R-tree. Finally, existing software was used to visualize 3D objects structured with the implemented 3D primitive. This research is a first attempt to implement a true 3D primitive in a DBMS. Future research will focus on extending and improving the implementations and on optimizing maintenance and query of 3D objects in DBMSs.

  1. Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 Tesla

    International Nuclear Information System (INIS)

    Rehnitz, C.; Klaan, B.; Amarteifio, E.; Kauczor, H.U.; Weber, M.A.; Stillfried, F. von; Burkholder, I.

    2016-01-01

    To compare the image quality of modern 3 D and 2 D sequences for dedicated wrist imaging at 3 Tesla (T) MRI. At 3 T MRI, 18 patients (mean age: 36.2 years) with wrist pain and 16 healthy volunteers (mean age: 26.4 years) were examined using 2 D proton density-weighted fat-saturated (PDfs), isotropic 3 D TrueFISP, 3 D MEDIC, and 3 D PDfs SPACE sequences. Image quality was rated on a five-point scale (0 - 4) including overall image quality (OIQ), visibility of important structures (cartilage, ligaments, TFCC) and degree of artifacts. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) of cartilage/bone/muscle/fluid as well as the mean overall SNR/CNR were calculated using region-of-interest analysis. ANOVA, paired t-, and Wilcoxon-signed-rank tests were applied. The image quality of all tested sequences was superior to 3 D PDfs SPACE (p < 0.01). 3 D TrueFISP had the highest combined cartilage score (mean: 3.4) and performed better in cartilage comparisons against 3 D PDfs SPACE in both groups and 2 D PDfs in volunteers (p < 0.05). 3 D MEDIC performed better in 7 of 8 comparisons (p < 0.05) regarding ligaments and TFCC. 2 D PDfs provided constantly high scores. The mean overall SNR/CNR for 2 D PDfs, 3 D PDfs SPACE, 3 D TrueFISP, and 3 D MEDIC were 68/65, 32/27, 45/47, and 57/45, respectively. 2 D PDfs performed best in most SNR/CNR comparisons (p < 0.05) and 3 D MEDIC performed best within the 3 D sequences (p < 0.05). Except 3 D PDfs SPACE, all tested 3 D and 2 D sequences provided high image quality. 3 D TrueFISP was best for cartilage imaging, 3 D MEDIC for ligaments and TFCC and 2 D PDfs for general wrist imaging.

  2. Cd3(MoO4)(TeO3)2: A Polar 3D Compound Containing d10-d0 SCALP-Effect Cations.

    Science.gov (United States)

    Feng, Yuquan; Fan, Huitao; Zhong, Zhiguo; Wang, Hongwei; Qiu, Dongfang

    2016-11-21

    The new polar 3D cadmium molybdotellurite Cd 3 (MoO 4 )(TeO 3 ) 2 was obtained by means of a high-temperature solid-state method. Cd 3 (MoO 4 )(TeO 3 ) 2 is a monoclinic crystal system, and it exhibits the polar space group P2 1 (No. 4). The structure of Cd 3 (MoO 4 )(TeO 3 ) 2 can be viewed as a complicated 3D architecture that is composed of distorted CdO n (n = 6, 7) polyhedra, TeO 3 trigonal pyramids, and MoO 4 polyhedra. The compound features the first 3D NCS cadmium molybdotellurite with 1D 4- and 6-MR channels and a polar structure originating from the TeO 3 groups, MoO 4 groups, and displacements of d 10 Cd 2+ cations. The results were further confirmed by calculations of the net polarization. The UV-vis spectrum and thermal properties indicate that Cd 3 (MoO 4 )(TeO 3 ) 2 exhibits a broad transparent region and excellent thermal stability. SHG tests of Cd 3 (MoO 4 )(TeO 3 ) 2 revealed that its response is approximately the same as that of KH 2 PO 4 at the same grain size between 105 and 150 μm and that it is phase-matchable.

  3. 3D Bayesian contextual classifiers

    DEFF Research Database (Denmark)

    Larsen, Rasmus

    2000-01-01

    We extend a series of multivariate Bayesian 2-D contextual classifiers to 3-D by specifying a simultaneous Gaussian distribution for the feature vectors as well as a prior distribution of the class variables of a pixel and its 6 nearest 3-D neighbours.......We extend a series of multivariate Bayesian 2-D contextual classifiers to 3-D by specifying a simultaneous Gaussian distribution for the feature vectors as well as a prior distribution of the class variables of a pixel and its 6 nearest 3-D neighbours....

  4. 3-D discrete analytical ridgelet transform.

    Science.gov (United States)

    Helbert, David; Carré, Philippe; Andres, Eric

    2006-12-01

    In this paper, we propose an implementation of the 3-D Ridgelet transform: the 3-D discrete analytical Ridgelet transform (3-D DART). This transform uses the Fourier strategy for the computation of the associated 3-D discrete Radon transform. The innovative step is the definition of a discrete 3-D transform with the discrete analytical geometry theory by the construction of 3-D discrete analytical lines in the Fourier domain. We propose two types of 3-D discrete lines: 3-D discrete radial lines going through the origin defined from their orthogonal projections and 3-D planes covered with 2-D discrete line segments. These discrete analytical lines have a parameter called arithmetical thickness, allowing us to define a 3-D DART adapted to a specific application. Indeed, the 3-D DART representation is not orthogonal, It is associated with a flexible redundancy factor. The 3-D DART has a very simple forward/inverse algorithm that provides an exact reconstruction without any iterative method. In order to illustrate the potentiality of this new discrete transform, we apply the 3-D DART and its extension to the Local-DART (with smooth windowing) to the denoising of 3-D image and color video. These experimental results show that the simple thresholding of the 3-D DART coefficients is efficient.

  5. 2D-3D rigid registration to compensate for prostate motion during 3D TRUS-guided biopsy.

    Science.gov (United States)

    De Silva, Tharindu; Fenster, Aaron; Cool, Derek W; Gardi, Lori; Romagnoli, Cesare; Samarabandu, Jagath; Ward, Aaron D

    2013-02-01

    Three-dimensional (3D) transrectal ultrasound (TRUS)-guided systems have been developed to improve targeting accuracy during prostate biopsy. However, prostate motion during the procedure is a potential source of error that can cause target misalignments. The authors present an image-based registration technique to compensate for prostate motion by registering the live two-dimensional (2D) TRUS images acquired during the biopsy procedure to a preacquired 3D TRUS image. The registration must be performed both accurately and quickly in order to be useful during the clinical procedure. The authors implemented an intensity-based 2D-3D rigid registration algorithm optimizing the normalized cross-correlation (NCC) metric using Powell's method. The 2D TRUS images acquired during the procedure prior to biopsy gun firing were registered to the baseline 3D TRUS image acquired at the beginning of the procedure. The accuracy was measured by calculating the target registration error (TRE) using manually identified fiducials within the prostate; these fiducials were used for validation only and were not provided as inputs to the registration algorithm. They also evaluated the accuracy when the registrations were performed continuously throughout the biopsy by acquiring and registering live 2D TRUS images every second. This measured the improvement in accuracy resulting from performing the registration, continuously compensating for motion during the procedure. To further validate the method using a more challenging data set, registrations were performed using 3D TRUS images acquired by intentionally exerting different levels of ultrasound probe pressures in order to measure the performance of our algorithm when the prostate tissue was intentionally deformed. In this data set, biopsy scenarios were simulated by extracting 2D frames from the 3D TRUS images and registering them to the baseline 3D image. A graphics processing unit (GPU)-based implementation was used to improve the

  6. The NIH 3D Print Exchange: A Public Resource for Bioscientific and Biomedical 3D Prints.

    Science.gov (United States)

    Coakley, Meghan F; Hurt, Darrell E; Weber, Nick; Mtingwa, Makazi; Fincher, Erin C; Alekseyev, Vsevelod; Chen, David T; Yun, Alvin; Gizaw, Metasebia; Swan, Jeremy; Yoo, Terry S; Huyen, Yentram

    2014-09-01

    The National Institutes of Health (NIH) has launched the NIH 3D Print Exchange, an online portal for discovering and creating bioscientifically relevant 3D models suitable for 3D printing, to provide both researchers and educators with a trusted source to discover accurate and informative models. There are a number of online resources for 3D prints, but there is a paucity of scientific models, and the expertise required to generate and validate such models remains a barrier. The NIH 3D Print Exchange fills this gap by providing novel, web-based tools that empower users with the ability to create ready-to-print 3D files from molecular structure data, microscopy image stacks, and computed tomography scan data. The NIH 3D Print Exchange facilitates open data sharing in a community-driven environment, and also includes various interactive features, as well as information and tutorials on 3D modeling software. As the first government-sponsored website dedicated to 3D printing, the NIH 3D Print Exchange is an important step forward to bringing 3D printing to the mainstream for scientific research and education.

  7. Effect of viewing distance on 3D fatigue caused by viewing mobile 3D content

    Science.gov (United States)

    Mun, Sungchul; Lee, Dong-Su; Park, Min-Chul; Yano, Sumio

    2013-05-01

    With an advent of autostereoscopic display technique and increased needs for smart phones, there has been a significant growth in mobile TV markets. The rapid growth in technical, economical, and social aspects has encouraged 3D TV manufacturers to apply 3D rendering technology to mobile devices so that people have more opportunities to come into contact with many 3D content anytime and anywhere. Even if the mobile 3D technology leads to the current market growth, there is an important thing to consider for consistent development and growth in the display market. To put it briefly, human factors linked to mobile 3D viewing should be taken into consideration before developing mobile 3D technology. Many studies have investigated whether mobile 3D viewing causes undesirable biomedical effects such as motion sickness and visual fatigue, but few have examined main factors adversely affecting human health. Viewing distance is considered one of the main factors to establish optimized viewing environments from a viewer's point of view. Thus, in an effort to determine human-friendly viewing environments, this study aims to investigate the effect of viewing distance on human visual system when exposing to mobile 3D environments. Recording and analyzing brainwaves before and after watching mobile 3D content, we explore how viewing distance affects viewing experience from physiological and psychological perspectives. Results obtained in this study are expected to provide viewing guidelines for viewers, help ensure viewers against undesirable 3D effects, and lead to make gradual progress towards a human-friendly mobile 3D viewing.

  8. From 2D Lithography to 3D Patterning

    NARCIS (Netherlands)

    Van Zeijl, H.W.; Wei, J.; Shen, C.; Verhaar, T.M.; Sarro, P.M.

    2010-01-01

    Lithography as developed for IC device fabrication is a high volume high accuracy patterning technology with strong 2 dimensional (2D) characteristics. This 2D nature makes it a challenge to integrate this technology in a 3 dimensional (3D) manufacturing environment. This article addresses the

  9. RELAP5-3D User Problems

    Energy Technology Data Exchange (ETDEWEB)

    Riemke, Richard Allan

    2002-09-01

    The Reactor Excursion and Leak Analysis Program with 3D capability1 (RELAP5-3D) is a reactor system analysis code that has been developed at the Idaho National Engineering and Environmental Laboratory (INEEL) for the U. S. Department of Energy (DOE). The 3D capability in RELAP5-3D includes 3D hydrodynamics2 and 3D neutron kinetics3,4. Assessment, verification, and validation of the 3D capability in RELAP5-3D is discussed in the literature5,6,7,8,9,10. Additional assessment, verification, and validation of the 3D capability of RELAP5-3D will be presented in other papers in this users seminar. As with any software, user problems occur. User problems usually fall into the categories of input processing failure, code execution failure, restart/renodalization failure, unphysical result, and installation. This presentation will discuss some of the more generic user problems that have been reported on RELAP5-3D as well as their resolution.

  10. Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

    Directory of Open Access Journals (Sweden)

    Saatchi Mahesh Kuwelker

    2017-01-01

    Full Text Available Tricuspid valve (TV injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD with Amplatzer ductal occluder I (ADO I, requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR.

  11. 3D Tree Dimensionality Assessment Using Photogrammetry and Small Unmanned Aerial Vehicles.

    Science.gov (United States)

    Gatziolis, Demetrios; Lienard, Jean F; Vogs, Andre; Strigul, Nikolay S

    2015-01-01

    Detailed, precise, three-dimensional (3D) representations of individual trees are a prerequisite for an accurate assessment of tree competition, growth, and morphological plasticity. Until recently, our ability to measure the dimensionality, spatial arrangement, shape of trees, and shape of tree components with precision has been constrained by technological and logistical limitations and cost. Traditional methods of forest biometrics provide only partial measurements and are labor intensive. Active remote technologies such as LiDAR operated from airborne platforms provide only partial crown reconstructions. The use of terrestrial LiDAR is laborious, has portability limitations and high cost. In this work we capitalized on recent improvements in the capabilities and availability of small unmanned aerial vehicles (UAVs), light and inexpensive cameras, and developed an affordable method for obtaining precise and comprehensive 3D models of trees and small groups of trees. The method employs slow-moving UAVs that acquire images along predefined trajectories near and around targeted trees, and computer vision-based approaches that process the images to obtain detailed tree reconstructions. After we confirmed the potential of the methodology via simulation we evaluated several UAV platforms, strategies for image acquisition, and image processing algorithms. We present an original, step-by-step workflow which utilizes open source programs and original software. We anticipate that future development and applications of our method will improve our understanding of forest self-organization emerging from the competition among trees, and will lead to a refined generation of individual-tree-based forest models.

  12. Triangulation-based 3D surveying borescope

    Science.gov (United States)

    Pulwer, S.; Steglich, P.; Villringer, C.; Bauer, J.; Burger, M.; Franz, M.; Grieshober, K.; Wirth, F.; Blondeau, J.; Rautenberg, J.; Mouti, S.; Schrader, S.

    2016-04-01

    In this work, a measurement concept based on triangulation was developed for borescopic 3D-surveying of surface defects. The integration of such measurement system into a borescope environment requires excellent space utilization. The triangulation angle, the projected pattern, the numerical apertures of the optical system, and the viewing angle were calculated using partial coherence imaging and geometric optical raytracing methods. Additionally, optical aberrations and defocus were considered by the integration of Zernike polynomial coefficients. The measurement system is able to measure objects with a size of 50 μm in all dimensions with an accuracy of +/- 5 μm. To manage the issue of a low depth of field while using an optical high resolution system, a wavelength dependent aperture was integrated. Thereby, we are able to control depth of field and resolution of the optical system and can use the borescope in measurement mode with high resolution and low depth of field or in inspection mode with low resolution and higher depth of field. First measurements of a demonstrator system are in good agreement with our simulations.

  13. 3D for Graphic Designers

    CERN Document Server

    Connell, Ellery

    2011-01-01

    Helping graphic designers expand their 2D skills into the 3D space The trend in graphic design is towards 3D, with the demand for motion graphics, animation, photorealism, and interactivity rapidly increasing. And with the meteoric rise of iPads, smartphones, and other interactive devices, the design landscape is changing faster than ever.2D digital artists who need a quick and efficient way to join this brave new world will want 3D for Graphic Designers. Readers get hands-on basic training in working in the 3D space, including product design, industrial design and visualization, modeling, ani

  14. 3D vector flow imaging

    DEFF Research Database (Denmark)

    Pihl, Michael Johannes

    The main purpose of this PhD project is to develop an ultrasonic method for 3D vector flow imaging. The motivation is to advance the field of velocity estimation in ultrasound, which plays an important role in the clinic. The velocity of blood has components in all three spatial dimensions, yet...... are (vx, vy, vz) = (-0.03, 95, 1.0) ± (9, 6, 1) cm/s compared with the expected (0, 96, 0) cm/s. Afterwards, 3D vector flow images from a cross-sectional plane of the vessel are presented. The out of plane velocities exhibit the expected 2D circular-symmetric parabolic shape. The experimental results...... verify that the 3D TO method estimates the complete 3D velocity vectors, and that the method is suitable for 3D vector flow imaging....

  15. RELAP5-3D User Problems

    International Nuclear Information System (INIS)

    Riemke, Richard Allan

    2001-01-01

    The Reactor Excursion and Leak Analysis Program with 3D capability (RELAP5-3D) is a reactor system analysis code that has been developed at the Idaho National Engineering and Environmental Laboratory (INEEL) for the U. S. Department of Energy (DOE). The 3D capability in RELAP5-3D includes 3D hydrodynamics and 3D neutron kinetics. Assessment, verification, and validation of the 3D capability in RELAP5-3D is discussed in the literature. Additional assessment, verification, and validation of the 3D capability of RELAP5-3D will be presented in other papers in this users seminar. As with any software, user problems occur. User problems usually fall into the categories of input processing failure, code execution failure, restart/renodalization failure, unphysical result, and installation. This presentation will discuss some of the more generic user problems that have been reported on RELAP5-3D as well as their resolution

  16. Advanced 3-D Ultrasound Imaging

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer

    The main purpose of the PhD project was to develop methods that increase the 3-D ultrasound imaging quality available for the medical personnel in the clinic. Acquiring a 3-D volume gives the medical doctor the freedom to investigate the measured anatomy in any slice desirable after the scan has...... been completed. This allows for precise measurements of organs dimensions and makes the scan more operator independent. Real-time 3-D ultrasound imaging is still not as widespread in use in the clinics as 2-D imaging. A limiting factor has traditionally been the low image quality achievable using...... a channel limited 2-D transducer array and the conventional 3-D beamforming technique, Parallel Beamforming. The first part of the scientific contributions demonstrate that 3-D synthetic aperture imaging achieves a better image quality than the Parallel Beamforming technique. Data were obtained using both...

  17. DELTA 3D PRINTER

    Directory of Open Access Journals (Sweden)

    ȘOVĂILĂ Florin

    2016-07-01

    Full Text Available 3D printing is a very used process in industry, the generic name being “rapid prototyping”. The essential advantage of a 3D printer is that it allows the designers to produce a prototype in a very short time, which is tested and quickly remodeled, considerably reducing the required time to get from the prototype phase to the final product. At the same time, through this technique we can achieve components with very precise forms, complex pieces that, through classical methods, could have been accomplished only in a large amount of time. In this paper, there are presented the stages of a 3D model execution, also the physical achievement after of a Delta 3D printer after the model.

  18. 3-D Discrete Analytical Ridgelet Transform

    OpenAIRE

    Helbert , David; Carré , Philippe; Andrès , Éric

    2006-01-01

    International audience; In this paper, we propose an implementation of the 3-D Ridgelet transform: the 3-D discrete analytical Ridgelet transform (3-D DART). This transform uses the Fourier strategy for the computation of the associated 3-D discrete Radon transform. The innovative step is the definition of a discrete 3-D transform with the discrete analytical geometry theory by the construction of 3-D discrete analytical lines in the Fourier domain. We propose two types of 3-D discrete lines:...

  19. Growth kinetics of tetragonal and monoclinic ZrO{sub 2} crystallites in 3 mol% yttria partially stabilized ZrO{sub 2} (3Y-PSZ) precursor powder

    Energy Technology Data Exchange (ETDEWEB)

    Kuo, Chih-Wei [Department of Resources Engineering, National Cheng Kung University, 1 Ta-Hsueh Road, Tainan 70101, Taiwan (China); Lee, Kuen-Chan [Department of Fragrance and Cosmetic Science, Kaohsiung Medical University, 100 Shih-Chuan 1st Road, Kaohsiung 807, Taiwan (China); Yen, Feng-Lin, E-mail: flyen@kmu.edu.tw [Department of Fragrance and Cosmetic Science, Kaohsiung Medical University, 100 Shih-Chuan 1st Road, Kaohsiung 807, Taiwan (China); Shen, Yun-Hwei [Department of Resources Engineering, National Cheng Kung University, 1 Ta-Hsueh Road, Tainan 70101, Taiwan (China); Lee, Huey-Er [Department of Dentistry, Kaohsiung Medical University, 100 Shih-Chuan 1st Road, Kaohsiung 807, Taiwan (China); Department of Dentistry, Kaohsiung Medical University, Chung Ho Memorial Hospital, 100 Tzyou 1st Road, Kaohsiung 807, Taiwan (China); Wen, Shaw-Bing [General Education Center, Meiho Institute of Technology, 23 Pingguang Road, Neipu, Pingtung 91202, Taiwan (China); Wang, Moo-Chin, E-mail: mcwang@kmu.edu.tw [Department of Fragrance and Cosmetic Science, Kaohsiung Medical University, 100 Shih-Chuan 1st Road, Kaohsiung 807, Taiwan (China); Stack, Margaret Mary [Department of Mechanical and Aerospace Engineering, University of Strathclyde, 75 Montrose Street, Glasgow (United Kingdom)

    2014-04-01

    Highlights: • The crystalline structures were composed of tetragonal and monoclinic ZrO{sub 2}. • Growth kinetics of t-ZrO{sub 2} in the 3Y-PSZ precursor powder is described as: D{sub te}{sup 2}=(4.57±0.55)t{sup 0.12±0.02}exp(-((24.79±0.38)×10{sup 3})/(RT) ). • Growth kinetics of m-ZrO{sub 2} in the 3Y-PSZ precursor powder is described as: D{sub m}{sup 2}=(4.40±1.63)t{sup 0.17±0.08}exp(-((66.47±3.97)×10{sup 3})/(RT) ). - Abstract: The growth kinetics of tetragonal and monoclinic ZrO{sub 2} crystallites in 3 mol% yttria partially stabilized ZrO{sub 2} (3Y-PSZ) precursor powder has been investigated using X-ray diffraction (XRD), Brunauer–Emmett–Teller (BET) specific surface area analysis, transmission electron microscopy (TEM) and high resolution TEM (HRTEM). After calcination of the 3Y-PSZ precursor powder between 773 and 1073 K for 2 h, the crystalline structures were composed of tetragonal and monoclinic ZrO{sub 2} as the primary and secondary phases, respectively. When the 3Y-PSZ precursor powder was calcined at 773 K for 2 h, the BET specific surface area was 97.13 m{sup 2}/g, which is equivalent to a particle size of 10.30 nm. The crystallite sizes determined via XRD and BET agreed well, indicating that the powder was virtually non-agglomerated. The growth kinetics of tetragonal and monoclinic ZrO{sub 2} crystallite isothermal growth in the 3Y-PSZ precursor powder are described by: D{sub te}{sup 2}=(4.57±0.55)t{sup 0.12±0.02}exp(-((24.79±0.38)×10{sup 3})/(RT) ) and D{sub m}{sup 2}=(4.40±1.63)t{sup 0.17±0.08}exp(-((66.47±3.97)×10{sup 3})/(RT) ), respectively, for 773K≤T≤1073K. D{sub te} and D{sub m} denote the crystallite size of tetragonal and monoclinic ZrO{sub 2} at time t and temperature T, respectively.

  20. Isotope effects in aqueous systems. Excess thermodynamic properties of 1,3-dimethylurea solutions in H2O and D2O

    International Nuclear Information System (INIS)

    Jakli, G.; Hook, W.A. Van

    1997-01-01

    The osmotic coefficients of 1,3-dimethylurea-h 2 (DMUh 2 )/H 2 O and 1,3-dimethylurea-d 2 (DMUd 2 )/D 2 O solutions (1, 2, 4, 12, and 20 m aq , 15 < t/degree C < 80) were obtained from differential vapor pressure measurements. Excess partial molar free energies, enthalpies, and entropies for the solvent and their isotope effects were calculated from the temperature derivatives of the osmotic coefficients. New partial molar volume data are reported at 25 C at low and intermediate concentrations. The thermodynamic properties of solution are compared with those of urea and discussed using the cage model of hydrophobic hydration. The results support the mixed (polar-apolar) character of this compound and show that its structural effect on water changes with temperature and concentration

  1. Voltammetric Studies on Vitamins D2 and D3 in Organic Solvents

    International Nuclear Information System (INIS)

    Chan, Ya Yun; Yue, Yanni; Webster, Richard D.

    2014-01-01

    Highlights: • Vitamins D 2 and D 3 undergo a chemically irreversible oxidation process. • The electrochemical oxidation occurs via one-electron on short (CV) time-scales. • On long time scales (electrolysis) the oxidation occurs via two-electrons. • Chemical oxidation was performed using two molar equivalents of NO + . • Oxidation occurs at the triene moiety. - Abstract: The electrochemical behavior of vitamins D 2 and D 3 were examined by performing cyclic voltammetry (CV), rotating disk electrode voltammetry, controlled potential electrolysis and chemical oxidation in aprotic organic solvents. Both vitamins were electrochemically oxidized in dichloromethane and acetonitrile (E p ox ∼ +0.8 vs. (Fc/Fc + )/V, where E p ox is the anodic peak potential and Fc = ferrocene) via a one-electron chemically irreversible process on the short voltammetric time scale (≤ seconds). Varying the scan rate (0.1 V s −1 to 20 V s −1 ) and temperature (233 K to 293 K) did not strongly affect the voltammetric response recorded on platinum and glassy carbon electrode surfaces with the oxidation process remaining chemically irreversible over the range of scan rates and temperatures tested, indicating that the initially formed cation radical was not long-lived. Repetitive CV experiments indicated that the oxidized product partially adsorbed onto the electrode surface, resulting in diminishing peak currents with multiple scans. Bulk controlled potential electrolysis of the vitamin D compounds performed by alternating several cycles of oxidative electrolysis and reductive pulsed stripping proved to be effective in stripping the adsorbed species off the electrode surfaces. Longer time scale bulk electrolysis experiments led to the detection of a new oxidation peak appearing at less positive potentials as the electrolysis progressed, suggesting that the compounds underwent oxidation on long time scales (minutes to hours) via a two electron process. The vitamins were most

  2. Tissue content of vitamin D3 and 25-hydroxy vitamin D3 in minipigs after cutaneous synthesis, supplementation and deprivation of vitamin D3

    DEFF Research Database (Denmark)

    Burild, Anders; Frandsen, Henrik Lauritz; Poulsen, Morten

    2015-01-01

    storages of vitamin D3 two studies were carried out in Göttingen minipigs. In study 1 one group of minipigs (n=2) was daily exposed to UV light corresponding to 10–20min of midday sun and another group (n=2) of pigs were fed up to 60μg vitamin D3/day corresponding to 3.7–4.4μg/kg body weight.Study 1......-hydroxy vitamin D3 in serum and skin- and subcutaneous adipose tissue biopsies were repeatedly monitored. Vitamin D3 and 25-hydroxy vitamin D3 were eliminated from the skin and the adipose tissue after UV-exposure was ceased. Supplementation of 13C-vitamin D3 did not seem to affect the decline...... demonstrated that daily UV-exposure of minipigs stimulated the cutaneous synthesis of vitamin D3 and resulted in increasing serum vitamin D3 and 25-hydroxy vitamin D3, but also carcasses containing vitamin D3 and 25-hydroxy vitamin D3. The vitamin D3 content in adipose tissue from the UV-exposed minipigs...

  3. Use of a 3D Skull Model to Improve Accuracy in Cranioplasty for Autologous Flap Resorption in a 3-Year-Old Child.

    Science.gov (United States)

    Maduri, Rodolfo; Viaroli, Edoardo; Levivier, Marc; Daniel, Roy T; Messerer, Mahmoud

    2017-01-01

    Cranioplasty is considered a simple reconstructive procedure, usually performed in a single stage. In some clinical conditions, such as in children with multifocal flap osteolysis, it could represent a surgical challenge. In these patients, the partially resorbed autologous flap should be removed and replaced with a precustomed prosthesis which should perfectly match the expected bone defect. We describe the technique used for a navigated cranioplasty in a 3-year-old child with multifocal autologous flap osteolysis. We decided to perform a cranioplasty using a custom-made hydroxyapatite porous ceramic flap. The prosthesis was produced with an epoxy resin 3D skull model of the patient, which included a removable flap corresponding to the planned cranioplasty. Preoperatively, a CT scan of the 3D skull model was performed without the removable flap. The CT scan images of the 3D skull model were merged with the preoperative 3D CT scan of the patient and navigated during the cranioplasty to define with precision the cranioplasty margins. After removal of the autologous resorbed flap, the hydroxyapatite prosthesis matched perfectly with the skull defect. The anatomical result was excellent. Thus, the implementation of cranioplasty with image merge navigation of a 3D skull model may improve cranioplasty accuracy, allowing precise anatomic reconstruction in complex skull defect cases. © 2017 S. Karger AG, Basel.

  4. Use of the Amplatzer ASD Occluder for Closing a Persistent Left Vertical Vein

    International Nuclear Information System (INIS)

    Zanchetta, Mario; Zennaro, Marco; Zecchel, Roberto; Mancuso, Daniela; Pedon, Luigi

    2009-01-01

    We report the case of a very large anomalous connection of the veins draining the upper lobe of the left lung to both the left-sided vertical vein and the left atrium, associated with mild rheumatic mitral valve stenosis, in which the atrial septum was intact and the remaining venous system, including the coronary sinus, was otherwise normal (a variant of Lutembacher's syndrome). In order to abolish the left-to-right shunting, a transcatheter approach to close this venous structure was successfully attempted using an Amplatzer ASD Occluder device. The technical aspects and the alternative options of performing a procedure with a device for a purpose outside the scope of its approved label are discussed.

  5. In situ repair of bone and cartilage defects using 3D scanning and 3D printing.

    Science.gov (United States)

    Li, Lan; Yu, Fei; Shi, Jianping; Shen, Sheng; Teng, Huajian; Yang, Jiquan; Wang, Xingsong; Jiang, Qing

    2017-08-25

    Three-dimensional (3D) printing is a rapidly emerging technology that promises to transform tissue engineering into a commercially successful biomedical industry. However, the use of robotic bioprinters alone is not sufficient for disease treatment. This study aimed to report the combined application of 3D scanning and 3D printing for treating bone and cartilage defects. Three different kinds of defect models were created to mimic three orthopedic diseases: large segmental defects of long bones, free-form fracture of femoral condyle, and International Cartilage Repair Society grade IV chondral lesion. Feasibility of in situ 3D bioprinting for these diseases was explored. The 3D digital models of samples with defects and corresponding healthy parts were obtained using high-resolution 3D scanning. The Boolean operation was used to achieve the shape of the defects, and then the target geometries were imported in a 3D bioprinter. Two kinds of photopolymerized hydrogels were synthesized as bioinks. Finally, the defects of bone and cartilage were restored perfectly in situ using 3D bioprinting. The results of this study suggested that 3D scanning and 3D bioprinting could provide another strategy for tissue engineering and regenerative medicine.

  6. 3-D magnetic field calculations for wiggglers using MAGNUS-3D

    International Nuclear Information System (INIS)

    Pissanetzky, S.; Tompkins, P.

    1988-01-01

    The recent but steady trend toward increased magnetic and geometric complexity in the design of wigglers and undulators, of which tapered wigglers, hybrid structures, laced electromagnetic wigglers, magnetic cladding, twisters and magic structures are examples, has caused a need for reliable 3-D computer models and a better understanding of the behavior of magnetic systems in three dimensions. The capabilities of the MAGNUS-3D Group of Programs are ideally suited to solve this class of problems and provide insight into 3-D effects. MAGNUS-3D can solve any problem of Magnetostatics involving permanent magnets, linear or nonlinear ferromagnetic materials and electric conductors of any shape in space. The magnetic properties of permanent magnets are described by the complete nonlinear demagnetization curve as provided by the manufacturer, or, at the user's choice, by a simpler approximation involving the coercive force, the residual induction and the direction of magnetization. The ferromagnetic materials are described by a magnetization table and an accurate interpolation relation. An internal library with properties of common industrial steels is available. The conductors are independent of the mesh and are described in terms of conductor elements from an internal library

  7. 3D printing utility for surgical treatment of acetabular fractures.

    Science.gov (United States)

    Chana Rodríguez, F; Pérez Mañanes, R; Narbona Cárceles, F J; Gil Martínez, P

    2018-05-25

    Preoperative 3D modelling enables more effective diagnosis and simulates the surgical procedure. We report twenty cases of acetabular fractures with preoperative planning performed by pre-contouring synthesis plates on a 3D printed mould obtained from a computarized tomography (CT) scan. The mould impression was made with the DaVinci 1.0 printer model (XYZ Printing). After obtaining the printed hemipelvis, we proceeded to select the implant size (pelvic Matta system, Stryker ® ) that matched the characteristics of the fracture and the approach to be used. Printing the moulds took a mean of 385minutes (322-539), and 238grams of plastic were used to print the model (180-410). In all cases, anatomic reduction was obtained and intra-operative changes were not required in the initial contouring of the plates. The time needed to perform the full osteosynthesis, once the fracture had been reduced was 16.9minutes (10-24). In one case fixed with two plates, a postoperative CT scan showed partial contact of the implant with the surface of the quadrilateral plate. In the remaining cases, the contact was complete. In conclusion, our results suggest that the use of preoperative planning, by printing 3D mirror imaging models of the opposite hemipelvis and pre-contouring plates over the mould, might effectively achieve a predefined surgical objective and reduce the inherent risks in these difficult procedures. Copyright © 2018. Publicado por Elsevier España, S.L.U.

  8. AxiSEM3D: broadband seismic wavefields in 3-D aspherical Earth models

    Science.gov (United States)

    Leng, K.; Nissen-Meyer, T.; Zad, K. H.; van Driel, M.; Al-Attar, D.

    2017-12-01

    Seismology is the primary tool for data-informed inference of Earth structure and dynamics. Simulating seismic wave propagation at a global scale is fundamental to seismology, but remains as one of most challenging problems in scientific computing, because of both the multiscale nature of Earth's interior and the observable frequency band of seismic data. We present a novel numerical method to simulate global seismic wave propagation in realistic 3-D Earth models. Our method, named AxiSEM3D, is a hybrid of spectral element method and pseudospectral method. It reduces the azimuthal dimension of wavefields by means of a global Fourier series parameterization, of which the number of terms can be locally adapted to the inherent azimuthal smoothness of the wavefields. AxiSEM3D allows not only for material heterogeneities, such as velocity, density, anisotropy and attenuation, but also for finite undulations on radial discontinuities, both solid-solid and solid-fluid, and thereby a variety of aspherical Earth features such as ellipticity, topography, variable crustal thickness, and core-mantle boundary topography. Such interface undulations are equivalently interpreted as material perturbations of the contiguous media, based on the "particle relabelling transformation". Efficiency comparisons show that AxiSEM3D can be 1 to 3 orders of magnitude faster than conventional 3-D methods, with the speedup increasing with simulation frequency and decreasing with model complexity, but for all realistic structures the speedup remains at least one order of magnitude. The observable frequency range of global seismic data (up to 1 Hz) has been covered for wavefield modelling upon a 3-D Earth model with reasonable computing resources. We show an application of surface wave modelling within a state-of-the-art global crustal model (Crust1.0), with the synthetics compared to real data. The high-performance C++ code is released at github.com/AxiSEM3D/AxiSEM3D.

  9. 3D PHOTOGRAPHS IN CULTURAL HERITAGE

    Directory of Open Access Journals (Sweden)

    W. Schuhr

    2013-07-01

    Full Text Available This paper on providing "oo-information" (= objective object-information on cultural monuments and sites, based on 3D photographs is also a contribution of CIPA task group 3 to the 2013 CIPA Symposium in Strasbourg. To stimulate the interest in 3D photography for scientists as well as for amateurs, 3D-Masterpieces are presented. Exemplary it is shown, due to their high documentary value ("near reality", 3D photography support, e.g. the recording, the visualization, the interpretation, the preservation and the restoration of architectural and archaeological objects. This also includes samples for excavation documentation, 3D coordinate calculation, 3D photographs applied for virtual museum purposes and as educational tools. In addition 3D photography is used for virtual museum purposes, as well as an educational tool and for spatial structure enhancement, which in particular holds for inscriptions and in rock arts. This paper is also an invitation to participate in a systematic survey on existing international archives of 3D photographs. In this respect it is also reported on first results, to define an optimum digitization rate for analog stereo views. It is more than overdue, in addition to the access to international archives for 3D photography, the available 3D photography data should appear in a global GIS(cloud-system, like on, e.g., google earth. This contribution also deals with exposing new 3D photographs to document monuments of importance for Cultural Heritage, including the use of 3D and single lense cameras from a 10m telescope staff, to be used for extremely low earth based airborne 3D photography, as well as for "underwater staff photography". In addition it is reported on the use of captive balloon and drone platforms for 3D photography in Cultural Heritage. It is liked to emphasize, the still underestimated 3D effect on real objects even allows, e.g., the spatial perception of extremely small scratches as well as of nuances in

  10. Rapid release of 42K and 86Rb from an occluded state of the Na,K-pump in the presence of ATP or ADP

    International Nuclear Information System (INIS)

    Forbush, B. III

    1987-01-01

    We have measured the time course of release of 42 K and 86 Rb from an occluded state of the Na,K-pump using a rapid filtration apparatus. We have found that at 20 degrees C and in the presence of ATP, 42 K is released with a rate constant of approximately 45 s-1 and 86 Rb with a rate constant of approximately 20 s-1; both ATP and ADP are effective at a low affinity site (Kd approximately 0.3 and 1 mM, respectively) with the rate of deocclusion being only half as great in ADP as in ATP. Mg2+ stimulates 2-fold at low concentrations probably by forming MgATP, and free Mg2+ is strongly inhibitory at high concentrations (Kd approximately 10 mM). Mg2+ also decreases the affinity for ATP, and the data are consistent with mixed type inhibition; from the analysis the dissociation constant is approximately 1 mM for the inhibitory Mg2+ and the Rb+-occluded form without ATP. The rate of 42 K or 86 Rb release increases monotonically with pH while ATPase activity decreases above pH 8, so that deocclusion is not rate-limiting in the overall cycle at high pH. This is reflected by a convergence of the rate of Na,K-ATPase and Na,Rb-ATPase activities at high pH and by a decrease in the observed steady-state level of the occluded 86 Rb intermediate at high pH. K+, Rb+, Na+, and Cs+, but not Li+, increase the rate of 42 K and 86 Rb release at constant ionic strength, presumably at sites other than the transport sites. The spontaneous rate of deocclusion is only approximately 0.1 s-1 at low ionic strength in the absence of nucleotides, and it is increased markedly by all cations tested except Li+. Overall the data are consistent with deocclusion as a rate-limiting step in the Na,K-pump cycle

  11. Body-part templates for recovery of 2D human poses under occlusion

    NARCIS (Netherlands)

    Poppe, Ronald Walter; Poel, Mannes; Perales, F.J.; Fisher, R.B.

    2008-01-01

    Detection of humans and estimation of their 2D poses from a single image are challenging tasks. This is especially true when part of the observation is occluded. However, given a limited class of movements, poses can be recovered given the visible body-parts. To this end, we propose a novel template

  12. T-junctions and perceived slant of partially occluded surfaces.

    Science.gov (United States)

    Grove, Philip M; Ono, Hiroshi; Kaneko, Hirohiko

    2003-01-01

    Häkkinen and Nyman (1997 Perception 26 29-38) reported that perceived slant is reduced when occlusion is a possible interpretation for the visual system. We present data from three experiments that confirm and expand on their finding. Our stimuli consisted of four types of stereograms depicting white central rectangles flanked on either side by two grey rectangles. The central white rectangles varied in height, thus manipulating the polarity of the T-junction information between the central and flanking rectangles. Perceived slant was smallest or not apparent when T-junction information indicated the central rectangles were nearer than the flanking rectangles and greatest when T-junction information indicated a farther central rectangle. Slant estimates for a stimulus containing a subjective pacmen-induced central rectangle were biased towards a depth step when an occlusion interpretation was possible.

  13. Activation of the marine ecosystem model 3D CEMBS for the Baltic Sea in operational mode

    Science.gov (United States)

    Dzierzbicka-Glowacka, Lidia; Jakacki, Jaromir; Janecki, Maciej; Nowicki, Artur

    2013-04-01

    The paper presents a new marine ecosystem model 3D CEMBS designed for the Baltic Sea. The ecosystem model is incorporated into the 3D POPCICE ocean-ice model. The Current Baltic Sea model is based on the Community Earth System Model (CESM from the National Center for Atmospheric Research) which was adapted for the Baltic Sea as a coupled sea-ice model. It consists of the Community Ice Code (CICE model, version 4.0) and the Parallel Ocean Program (version 2.1). The ecosystem model is a biological submodel of the 3D CEMBS. It consists of eleven mass conservation equations. There are eleven partial second-order differential equations of the diffusion type with the advective term for phytoplankton, zooplankton, nutrients, dissolved oxygen, and dissolved and particulate organic matter. This model is an effective tool for solving the problem of ecosystem bioproductivity. The model is forced by 48-hour atmospheric forecasts provided by the UM model from the Interdisciplinary Centre for Mathematical and Computational Modelling of Warsaw University (ICM). The study was financially supported by the Polish State Committee of Scientific Research (grants: No N N305 111636, N N306 353239). The partial support for this study was also provided by the project Satellite Monitoring of the Baltic Sea Environment - SatBaltyk founded by European Union through European Regional Development Fund contract no. POIG 01.01.02-22-011/09. Calculations were carried out at the Academy Computer Centre in Gdańsk.

  14. 3D Restoration Microscopy Improves Quantification of Enzyme-Labeled Fluorescence-Based Single-Cell Phosphatase Activity in Plankton

    OpenAIRE

    Diaz-de-Quijano, Daniel; Palacios, Pilar; Hornák, Karel; Felip, Marisol

    2014-01-01

    The ELF or fluorescence-labeled enzyme activity (FLEA) technique is a culture-independent single-cell tool for assessing plankton enzyme activity in close-to-in situ conditions. We demonstrate that single-cell FLEA quantifications based on two-dimensional (2D) image analysis were biased by up to one order of magnitude relative to deconvolved 3D. This was basically attributed to out-of-focus light, and partially to object size. Nevertheless, if sufficient cells were measured (25-40 cells), bia...

  15. Use of 3D reconstruction cloacagrams and 3D printing in cloacal malformations.

    Science.gov (United States)

    Ahn, Jennifer J; Shnorhavorian, Margarett; Amies Oelschlager, Anne-Marie E; Ripley, Beth; Shivaram, Giridhar M; Avansino, Jeffrey R; Merguerian, Paul A

    2017-08-01

    Cloacal anomalies are complex to manage, and the anatomy affects prognosis and management. Assessment historically includes examination under anesthesia, and genitography is often performed, but these do not consistently capture three-dimensional (3D) detail or spatial relationships of the anatomic structures. Three-dimensional reconstruction cloacagrams can provide a high level of detail including channel measurements and the level of the cloaca (3 cm), which typically determines the approach for surgical reconstruction and can impact long-term prognosis. Yet this imaging modality has not yet been directly compared with intra-operative or endoscopic findings. Our objective was to compare 3D reconstruction cloacagrams with endoscopic and intraoperative findings, as well as to describe the use of 3D printing to create models for surgical planning and education. An IRB-approved retrospective review of all cloaca patients seen by our multi-disciplinary program from 2014 to 2016 was performed. All patients underwent examination under anesthesia, endoscopy, 3D reconstruction cloacagram, and subsequent reconstructive surgery at a later date. Patient characteristics, intraoperative details, and measurements from endoscopy and cloacagram were reviewed and compared. One of the 3D cloacagrams was reformatted for 3D printing to create a model for surgical planning. Four patients were included for review, with the Figure illustrating 3D cloacagram results. Measurements of common channel length and urethral length were similar between modalities, particularly with confirming the level of cloaca. No patient experienced any complications or adverse effects from cloacagram or endoscopy. A model was successfully created from cloacagram images with the use of 3D printing technology. Accurate preoperative assessment for cloacal anomalies is important for counseling and surgical planning. Three-dimensional cloacagrams have been shown to yield a high level of anatomic detail. Here

  16. Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI.

    Science.gov (United States)

    Jeevanandham, Balaji; Kalyanpur, Tejas; Gupta, Prashant; Cherian, Mathew

    2017-06-01

    This study was to assess the usefulness of newer three-dimensional (3D)-T 1 sampling perfection with application optimized contrast using different flip-angle evolutions (SPACE) and 3D-T 2 fluid-attenuated inversion recovery (FLAIR) sequences in evaluation of meningeal abnormalities. 78 patients who presented with high suspicion of meningeal abnormalities were evaluated using post-contrast 3D-T 2 -FLAIR, 3D-T 1 magnetization-prepared rapid gradient-echo (MPRAGE) and 3D-T 1 -SPACE sequences. The images were evaluated independently by two radiologists for cortical gyral, sulcal space, basal cisterns and dural enhancement. The diagnoses were confirmed by further investigations including histopathology. Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images yielded significantly more information than MPRAGE images (p evaluation of meningeal abnormalities and when used in combination have the maximum sensitivity for leptomeningeal abnormalities. The negative-predictive value is nearly 100%, where no leptomeningeal abnormality was detected on these sequences. Advances in knowledge: Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images are more useful than 3D-T 1 -MPRAGE images in evaluation of meningeal abnormalities.

  17. Quantitative model for the generic 3D shape of ICMEs at 1 AU

    Science.gov (United States)

    Démoulin, P.; Janvier, M.; Masías-Meza, J. J.; Dasso, S.

    2016-10-01

    Context. Interplanetary imagers provide 2D projected views of the densest plasma parts of interplanetary coronal mass ejections (ICMEs), while in situ measurements provide magnetic field and plasma parameter measurements along the spacecraft trajectory, that is, along a 1D cut. The data therefore only give a partial view of the 3D structures of ICMEs. Aims: By studying a large number of ICMEs, crossed at different distances from their apex, we develop statistical methods to obtain a quantitative generic 3D shape of ICMEs. Methods: In a first approach we theoretically obtained the expected statistical distribution of the shock-normal orientation from assuming simple models of 3D shock shapes, including distorted profiles, and compared their compatibility with observed distributions. In a second approach we used the shock normal and the flux rope axis orientations together with the impact parameter to provide statistical information across the spacecraft trajectory. Results: The study of different 3D shock models shows that the observations are compatible with a shock that is symmetric around the Sun-apex line as well as with an asymmetry up to an aspect ratio of around 3. Moreover, flat or dipped shock surfaces near their apex can only be rare cases. Next, the sheath thickness and the ICME velocity have no global trend along the ICME front. Finally, regrouping all these new results and those of our previous articles, we provide a quantitative ICME generic 3D shape, including the global shape of the shock, the sheath, and the flux rope. Conclusions: The obtained quantitative generic ICME shape will have implications for several aims. For example, it constrains the output of typical ICME numerical simulations. It is also a base for studying the transport of high-energy solar and cosmic particles during an ICME propagation as well as for modeling and forecasting space weather conditions near Earth.

  18. 3D+time acquisitions of 3D cell culture by means of lens-free tomographic microscopy

    Science.gov (United States)

    Berdeu, Anthony; Laperrousaz, Bastien; Bordy, Thomas; Morales, S.; Gidrol, Xavier; Picollet-D'hahan, Nathalie; Allier, Cédric

    2018-02-01

    We propose a three-dimensional (3D) imaging platform based on lens-free microscopy to perform multi-angle acquisitions on 3D cell cultures embedded in extracellular matrix (ECM). We developed algorithms based on the Fourier diffraction theorem to perform fully 3D reconstructions of biological samples and we adapted the lens-free microscope to incubator conditions. Here we demonstrate for the first time, 3D+time lens-free acquisitions of 3D cell culture over 8 days directly into the incubator. The 3D reconstructed volume is as large as 5 mm3 and provides a unique way to observe in the same 3D cell culture experiment multiple cell migration strategies. Namely, in a 3D cell culture of prostate epithelial cells embedded within a Matrigel® matrix, we are able to distinguish single cell 'leaders', migration of cell clusters, migration of large aggregates of cells, and also close-gap and large-scale branching. In addition, we observe long-scale 3D deformations of the ECM that modify the geometry of the 3D cell culture. Interestingly, we also observed the opposite, i.e. we found that large aggregates of cells may deform the ECM by generating traction forces over very long distances. In sum we put forward a novel 3D lens-free microscopy tomographic technique to study the single and collective cell migrations, the cell-to-cell interactions and the cell-to-matrix interactions.

  19. - LAA Occluder View for post-implantation Evaluation (LOVE) - standardized imaging proposal evaluating implanted left atrial appendage occlusion devices by cardiac computed tomography

    International Nuclear Information System (INIS)

    Behnes, Michael; Akin, Ibrahim; Sartorius, Benjamin; Fastner, Christian; El-Battrawy, Ibrahim; Borggrefe, Martin; Haubenreisser, Holger; Meyer, Mathias; Schoenberg, Stefan O.; Henzler, Thomas

    2016-01-01

    A standardized imaging proposal evaluating implanted left atrial appendage (LAA) occlusion devices by cardiac computed tomography angiography (cCTA) has never been investigated. cCTA datasets were acquired on a 3 rd generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. An interdisciplinary evaluation was performed by two interventional cardiologists and one radiologist on a 3D multi-planar workstation. A standardized multi-planar reconstruction algorithm was developed in order to assess relevant clinical aspects of implanted LAA occlusion devices being outlined within a pictorial essay. The following clinical aspects of implanted LAA occlusion devices were evaluated within the most appropriate cCTA multi-planar reconstruction: (1) topography to neighboring structures, (2) peri-device leaks, (3) coverage of LAA lobes, (4) indirect signs of neo-endothelialization. These are illustrated within concise CT imaging examples emphasizing the potential value of the proposed cCTA imaging algorithm: Starting from anatomical cCTA planes and stepwise angulation planes perpendicular to the base of the LAA devices generates an optimal LAA Occluder View for post-implantation Evaluation (LOVE). Aligned true axial, sagittal and coronal LOVE planes offer a standardized and detailed evaluation of LAA occlusion devices after percutaneous implantation. This pictorial essay presents a standardized imaging proposal by cCTA using multi-planar reconstructions that enables systematical follow-up and comparison of patients after LAA occlusion device implantation. The online version of this article (doi:10.1186/s12880-016-0127-y) contains supplementary material, which is available to authorized users

  20. Underwater 3D filming

    OpenAIRE

    Rinaldi, Roberto

    2014-01-01

    After an experimental phase of many years, 3D filming is now effective and successful. Improvements are still possible, but the film industry achieved memorable success on 3D movie’s box offices due to the overall quality of its products. Special environments such as space (“Gravity” ) and the underwater realm look perfect to be reproduced in 3D. “Filming in space” was possible in “Gravity” using special effects and computer graphic. The underwater realm is still difficult to be handled. Unde...