WorldWideScience

Sample records for partial-thickness scleral channels

  1. Femtosecond laser subsurface scleral treatment in cadaver human sclera and evaluation using two-photon and confocal microscopy

    Science.gov (United States)

    Sun, Hui; Fan, Zhongwei; Yan, Ying; Lian, Fuqiang; Kurtz, Ron; Juhasz, Tibor

    2016-03-01

    Glaucoma is the second-leading cause of blindness worldwide and is often associated with elevated intraocular pressure (IOP). Partial-thickness drainage channels can be created with femtosecond laser in the translucent sclera for the potential treatment of glaucoma. We demonstrate the creation of partial-thickness subsurface drainage channels with the femtosecond laser in the cadaver human eyeballs and describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. A femtosecond laser operating at a wavelength of 1700 nm was scanned along a rectangular raster pattern to create the partial thickness subsurface drainage channels in the sclera of cadaver human eyes. Analysis of the dimensions and location of these channels is important in understanding their effects. We describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. High-resolution images, hundreds of microns deep in the sclera, were obtained to allow determination of the shape and dimension of such partial thickness subsurface scleral channels. Our studies suggest that the confocal and two-photon microscopy can be used to investigate femtosecond-laser created partial-thickness drainage channels in the sclera of cadaver human eyes.

  2. Partial Thickness Rotator Cuff Tears: Current Concepts

    Science.gov (United States)

    Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.

    2015-01-01

    Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251

  3. Partial Thickness Rotator Cuff Tears: Current Concepts

    Directory of Open Access Journals (Sweden)

    Graeme Matthewson

    2015-01-01

    Full Text Available Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized.

  4. Partial-thickness burn wounds healing by topical treatment

    OpenAIRE

    Saeidinia, Amin; Keihanian, Faeze; Lashkari, Ardalan Pasdaran; Lahiji, Hossein Ghavvami; Mobayyen, Mohammadreza; Heidarzade, Abtin; Golchai, Javad

    2017-01-01

    Abstract Background: Burns are common event and associated with a high incidence of death, disability, and high costs. Centella asiatica (L.) is a medicinal herb, commonly growing in humid areas in several tropical countries that improve wound healing. On the basis of previous studies, we compared the efficacy of Centiderm versus silver sulfadiazine (SSD) in partial thickness burning patients. Methods: Study population comprised burn victims referred to Velayat Burning Hospital at Rasht, Iran...

  5. Negative pressure wound therapy for partial-thickness burns.

    Science.gov (United States)

    Dumville, Jo C; Munson, Christopher; Christie, Janice

    2014-12-15

    A burn wound is a complex and evolving injury, with both local and systemic consequences. Burn treatments include a variety of dressings, as well as newer strategies, such as negative pressure wound therapy (NPWT), which, by means of a suction force that drains excess fluids from the burn, tries to promote the wound healing process and minimise progression of the burn wound. To assess the effectiveness of NPWT for people with partial-thickness burns. We searched the Cochrane Wounds Group Specialised Register (searched 04 September 2014); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 8). All randomised controlled trials (RCTs) and controlled clinical trials (CCTs) that evaluated the safety and effectiveness of NPWT for partial-thickness burns. Two review authors used standardised forms, and extracted the data independently. We assessed each trial for risk of bias, and resolved differences by discussion. One RCT, that was an interim report, satisfied the inclusion criteria. We undertook a narrative synthesis of results, as the absence of data and poor reporting precluded us from carrying out any formal statistical analysis. The trial was at high risk of bias. There was not enough evidence available to permit any conclusions to be drawn regarding the use of NPWT for treatment of partial-thickness burn wounds.

  6. MRI in diagnosing partial thickness tears of the rotator cuff

    International Nuclear Information System (INIS)

    Ogawa, Takeshi

    2000-01-01

    In this study 270 patients who had been treated for 10 years and had suspected rupture of the tendon and complete or partial thickness tears of the rotator cuff were diagnosed. Among these patients, MRI images in 50 cases were investigated to establish the diagnostic criteria for partial thickness tears of the rotator cuff. The rupture sites included the bursal surface in 15 shoulders, the articular surface in 30 shoulders, complicated cases of both surfaces in five shoulders with no intrasubstance. As for the imaging method, T2-weighted images were employed and the oblique coronary section, which is parallel to the scapula, was used as a imaging plane. From the results of the variation of the MRI signal intensity in the tendon, it was found that the signal intensity increased to 80% in the rupture of the bursal surface and 93.3% in the rupture of the articular surface. As for sites where the signals in the tendon increased, these were found at the bursal side in 83.3% of rupture at the bursal surface, and at the articular side in 100% of rupture at the articular surface. From these findings, the MRI-diagnostic criteria of partial thickness tears of the rotator cuff was defined as those cases which show a localized increase in signal intensity on the oblique coronary surface of T2 weighted images, but not in whole layers of the tendon. A high diagnostic rate with these criteria could be obtained with a sensitivity of 82.0%, specificity 90.9%, accuracy 84.7%, and positive predictive value 95.3%. (author)

  7. Preserved scleral patch graft for unexpected extreme scleral thinning found at the scleral buckling procedure: A case report

    Directory of Open Access Journals (Sweden)

    Spela Stunf

    2011-01-01

    Full Text Available Pre-existing scleral pathology is an important risk factor for globe rupture during scleral buckling procedures. We report here, the surgical management of an unexpected scleral pathology found at the scleral buckling procedure in a retinal detachment patient. A 77-year-old white female with retinal detachment underwent a scleral buckling procedure. The surgery was converted into a scleral graft procedure, as extreme scleral thinning was found intraoperatively. An alcohol-preserved donor sclera graft was used. The second surgery for definitive retinal alignment was performed two weeks later. The presented case of an unexpected scleral pathology in a retinal detachment patient was managed with a combination of scleral grafting and pars plana vitrectomy, without any major complications. The anatomical outcome was excellent and the scleral rupture was prevented; the visual outcome was satisfactory. A conversion of the scleral buckling procedure into a scleral graft procedure has proved to be safe and effective for unexpected scleral pathology.

  8. Partial-thickness burn wounds healing by topical treatment

    Science.gov (United States)

    Saeidinia, Amin; Keihanian, Faeze; Lashkari, Ardalan Pasdaran; Lahiji, Hossein Ghavvami; Mobayyen, Mohammadreza; Heidarzade, Abtin; Golchai, Javad

    2017-01-01

    Abstract Background: Burns are common event and associated with a high incidence of death, disability, and high costs. Centella asiatica (L.) is a medicinal herb, commonly growing in humid areas in several tropical countries that improve wound healing. On the basis of previous studies, we compared the efficacy of Centiderm versus silver sulfadiazine (SSD) in partial thickness burning patients. Methods: Study population comprised burn victims referred to Velayat Burning Hospital at Rasht, Iran. The intervention group received Centiderm and control group SSD cream. Burn wounds were treated once daily at home. All of the wounds were evaluated till complete healing occurred and at the admission, days 3, 7, 14 objective signs; visual acuity score (VAS) and subjective signs were recorded. Re-epithelialization time and complete healing days were recorded. We used random fixed block for randomization. The randomization sequence was created using the computer. Patients and burning specialist physician were blinded. Results: Seventy-five patients randomized into 2 groups; (40 patients: Centiderm group; 35 patients: SSD group). The mean age of them was 30.67 ± 9.91 years and 19 of them were male (31.7%). Thirty patients in Centiderm and 30 patients in SSD group were analyzed. All of objective and subjective signs and mean of re-epithelialization and complete healing were significantly better in Centiderm group rather than SSD group (P < 0.05). There was no infection in Centiderm group. Conclusions: We showed that use of Centiderm ointment not only improved the objective and subjective signs in less than 3 days, but also the re-epithelialization and complete healing rather than SSD without any infection in the subjects. PMID:28248871

  9. Optimal treatment of partial thickness burns in children: A systematic review

    NARCIS (Netherlands)

    Vloemans, A.F.P.M.; Hermans, M.; van der Wal, M.; Liebregts, J.; Middelkoop, E.

    2014-01-01

    A large part of the patient population of a burn centre consists of children, most of whom are younger than four years. The majority of these young children suffer from superficial and deep partial thickness scald burns that may easily deepen to full thickness burns. A proper wound therapy, that

  10. Honey compared with silver sulphadiazine in the treatment of superficial partial-thickness burns.

    Science.gov (United States)

    Malik, Kamran Ishaque; Malik, M A Nasir; Aslam, Azhar

    2010-10-01

    Burn injury is associated with a high incidence of death and disability; yet, its management remains problematic and costly. We conducted this clinical study to evaluate the efficacy of honey in the treatment of superficial and partial-thickness burns covering less than 40% of body surface area and compared its results with those of silver sulphadiazine (SSD). In this randomised comparative clinical trial, carried out Burn Center of POF Hospital, Wah Cantt, Pakistan, from May 2007 to February 2008, 150 patients of all ages having similar types of superficial and partial-thickness burns at two sites on different parts of body were included. Each patient had one burn site treated with honey and one treated with topical SSD, randomly. The rate of re-epithelialization and healing of superficial and partial-thickness burns was significantly faster in the sites treated with honey than in the sites treated with SSD (13·47 ± 4·06 versus 15·62 ± 4·40 days, respectively: P honey healed completely in less than 21 days versus 24 days for the site treated with SSD. Six patients had positive culture for Pseudomonas aeroginsa in honey-treated site, whereas 27 patients had positive culture in SSD-treated site. The results clearly showed greater efficacy of honey over SSD cream for treating superficial and partial-thickness burns. 2010 The Authors. Journal Compilation © 2010 Blackwell Publishing Ltd and Medicalhelplines.com Inc.

  11. Management of a facial partial thickness chemical burn in a dog caused by bleach.

    Science.gov (United States)

    Kawalilak, Lukas T; Fransson, Boel A; Alessio, Terri L

    2017-03-01

    To describe the management and successful outcome of a late-recognition partial thickness bleach burn to the face and corneas of a dog. A 1-year-old male neutered Fox Terrier mix breed dog was evaluated for sloughing facial epithelium 5 days after coming into contact with an 8.25% household bleach cleaning solution. Severe erythema, edema, and crusting were noted around the muzzle and margins of both eyes, with moderate to severe alopecia in these areas. A partially detached, partial thickness eschar was present on the muzzle, while a firmly attached eschar was present in the region of both frontal sinuses. These injuries were consistent with a focal, superficial, and partial thickness chemical burn. Multiple ocular abnormalities, the most concerning of which was corneal ulceration, were also present. The patient's wounds were managed conservatively with limited surgical debridement of the affected epithelium 11 and 22 days after the initial exposure. Topical ocular medications, corneal debridement, and a superficial keratectomy were also used. All lesions resolved completely by 84 days postexposure, with no residual effects on the patient's quality of life. Chemical burns caused by contact with alkaline agents such as bleach (sodium hypochlorite) result in extensive necrosis of the skin and underlying structures. This is the first report of management alkaline facial burns in a dog. If inadequate or delayed hydrotherapy following exposure has resulted in superficial partial thickness burns, conservative management can be successful when traditional treatments, especially bandaging, are not feasible. © Veterinary Emergency and Critical Care Society 2017.

  12. Comparisons of the Various Partial-Thickness Rotator Cuff Tears on MR Arthrography and Arthroscopic Correlation

    International Nuclear Information System (INIS)

    Chun, Kyung Ah; Kim, Min Sung; Kim, Young Joo

    2010-01-01

    To assess the diagnostic performance of MR arthrography in the diagnosis of the various types of partial-thickness rotator cuff tears by comparing the MR imaging findings with the arthroscopic findings. The series of MR arthrography studies included 202 patients consisting of 100 patients with partial-thickness rotator cuff tears proved by arthroscopy and a control group of 102 patients with arthroscopically intact rotator cuffs, which were reviewed in random order. At arthroscopy, 54 articularsided, 26 bursal-sided, 20 both articular- and bursal-sided partial-thickness tears were diagnosed. The MR arthrographies were analyzed by two radiologists for articular-sided tears, bursal-sided tears, and both articular- and bursal-sided tears of the rotator cuff. The sensitivity and specificity of each type of partial-thickness tears were determined. Kappa statistics was calculated to determine the interand intra-observer agreement of the diagnosis of partial-thickness rotator cuff tears. The sensitivity and specificity of the various types of rotator cuff tears were 85% and 90%, respectively for articular-sided tears, 62% and 95% for bursal- sided tears, as well as 45% and 99% for both articular- and bursal-sided tears. False-negative assessments were primarily observed in the diagnosis of bursal-sided tears. Conversely, both articular- and bursal-sided tears were overestimated as full-thickness tears. Inter-observer agreement was excellent for the diagnosis of articular-sided tears (k = 0.70), moderate (k = 0.59) for bursal-sided tears, and fair (k = 0.34) for both articular- and bursal-sided tears, respectively. Intra-observer agreement for the interpretation of articular- and bursal-sided tears was excellent and good, respectively, whereas intra-observer agreement for both articular- and bursal-sided tears was moderate. MR arthrography is a useful diagnostic tool for partial-thickness rotator cuff tears, but has limitations in that it has low sensitivity in bursal- and

  13. Comparisons of the Various Partial-Thickness Rotator Cuff Tears on MR Arthrography and Arthroscopic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Kyung Ah; Kim, Min Sung; Kim, Young Joo [Catholic University of Korea Uijeongbu St.Mary' s Hospital, Uijeongbu (Korea, Republic of)

    2010-10-15

    To assess the diagnostic performance of MR arthrography in the diagnosis of the various types of partial-thickness rotator cuff tears by comparing the MR imaging findings with the arthroscopic findings. The series of MR arthrography studies included 202 patients consisting of 100 patients with partial-thickness rotator cuff tears proved by arthroscopy and a control group of 102 patients with arthroscopically intact rotator cuffs, which were reviewed in random order. At arthroscopy, 54 articularsided, 26 bursal-sided, 20 both articular- and bursal-sided partial-thickness tears were diagnosed. The MR arthrographies were analyzed by two radiologists for articular-sided tears, bursal-sided tears, and both articular- and bursal-sided tears of the rotator cuff. The sensitivity and specificity of each type of partial-thickness tears were determined. Kappa statistics was calculated to determine the interand intra-observer agreement of the diagnosis of partial-thickness rotator cuff tears. The sensitivity and specificity of the various types of rotator cuff tears were 85% and 90%, respectively for articular-sided tears, 62% and 95% for bursal- sided tears, as well as 45% and 99% for both articular- and bursal-sided tears. False-negative assessments were primarily observed in the diagnosis of bursal-sided tears. Conversely, both articular- and bursal-sided tears were overestimated as full-thickness tears. Inter-observer agreement was excellent for the diagnosis of articular-sided tears (k = 0.70), moderate (k = 0.59) for bursal-sided tears, and fair (k = 0.34) for both articular- and bursal-sided tears, respectively. Intra-observer agreement for the interpretation of articular- and bursal-sided tears was excellent and good, respectively, whereas intra-observer agreement for both articular- and bursal-sided tears was moderate. MR arthrography is a useful diagnostic tool for partial-thickness rotator cuff tears, but has limitations in that it has low sensitivity in bursal- and

  14. Treatment of Partial Thickness Burns with a Novel Extracellular Matrix in Rats (Rattus norvegicus)

    Science.gov (United States)

    2016-12-20

    partial thickness burn was produced using a brass scale weight. Groups of 10 rats were randomly assigned to the various treatments . Jackets made from...Objectives: The objective this study was to examine the cellular and immune responses to various extracellular matrices (ECM) in a rat burn model...significant difference between treatments in terms of mean wound area (p = 0.77). Histologic examination revealed that all of the grafts were infected, with

  15. Effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit

    OpenAIRE

    Peng Xi; Yan Li; Xiaojin Ge; Dandan Liu; Mingsan Miao

    2018-01-01

    Objective: Observing the effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit. Method: We prepared boiling water scalded rabbits with deep II degree scald models and applied high, medium and low doses of nano-silver hydrogel coating film for different time and area. Then we compared the difference of burned paper weight before administration and after administration model burns, burn local skin irritation points infection, skin crusting and scabs from th...

  16. Anti-scar Treatment for Deep Partial-thickness Burn Wounds

    Science.gov (United States)

    2017-10-01

    applied topically to deep partial-thickness burn wounds reduced α-SMA protein expression ( ELISA ). Mouse burn wounds were treated with PFD twice...immediately and at 48 hrs post- burn. α-SMA in wound skin homogenates was assayed by ELISA . α-SMA protein was significantly lower in mice treated with...Inflammatory cytokines in wound skin homogenates were assayed by ELISA . This early treatment during the inflammatory stage of healing significantly reduced

  17. Scleral lens use in dry eye syndrome.

    Science.gov (United States)

    Bavinger, J Clay; DeLoss, Karen; Mian, Shahzad I

    2015-07-01

    Dry eye syndrome can be difficult to manage in severe or refractory cases. In patients in whom traditional treatments have limited efficacy, alternative treatments may be considered for dry eye syndrome, including scleral lenses. The present review summarizes the evidence regarding scleral lens use in dry eye syndrome. Scleral lenses have become a viable option for severe dry eye syndrome, and have been shown to be efficacious and well tolerated, with most reports citing improved visual acuity and relief of symptoms. Currently, there are 18 manufacturers of scleral lenses, although published reports on scleral lenses primarily focus on the BostonSight PROSE and the Jupiter Lens. Scleral lenses are efficacious and well tolerated for use in severe dry eye syndrome. Further research is needed to compare different sizes and types of lenses, and to standardize outcome measures.

  18. Use of a copolymer dressing on superficial and partial-thickness burns in a paediatric population.

    Science.gov (United States)

    Everett, M; Massand, S; Davis, W; Burkey, B; Glat, P M

    2015-07-01

    Despite extensive research into the treatment of partial-thickness burns, to date there has not been the emergence of a preeminent modality. This pilot study, the first such study to be performed in a burn unit in the US, was designed to evaluate the efficacy and outcomes of the application of copolymer dressing (Suprathel; PolyMedics Innovations Corporation, Stuttgart, Germany) for both superficial and deeper partial-thickness burns. The copolymer dressing was used as a primary wound dressing to treat superficial and deep partial-thickness burns (average 5% total body surface area) in paediatric patients. Burns were debrided within 24 hours, at bedside, in the burn unit or in the operating room. The copolymer dressing was then applied directly to the wound and covered with a non-adherent second layer and an absorptive outer dressing. After discharge, patients were seen every 5-7 days until healed. Parameters evaluated included average hospital length of stay, average number of intravenous doses of narcotics administered, pain score at first follow-up visit, average time to complete re epithelialisation, incidence of burn wound infection, and patient/parent satisfaction on a 4-point scale. We also evaluated our experience with the dressing. Data were evaluated retrospectively under an Investigational Review Board approved protocol. Of the 17 patients assessed the average hospital length of stay was 1.4 days during which the average number of intravenous narcotic doses administered before copolymer dressing application was 1.5 and after was 0.1 doses. At the first follow-up visit, average pain score was 1.2 on a 10-point scale and the average time to re epithelialisation was 9.5 days. There was no incidence of burn wound infection. Patient/parent satisfaction was average of 3.66 on a 4-point scale. The staff had found that the self-adherence and elasticity of the dressing made it easy to apply and stay adherent, especially in areas of difficult contour. There were

  19. The use of Hyalomatrix PA in the treatment of deep partial-thickness burns.

    Science.gov (United States)

    Gravante, Gianpiero; Delogu, Daniela; Giordan, Nicola; Morano, Giuseppina; Montone, Antonio; Esposito, Gaetano

    2007-01-01

    Since 2001, Hyalomatrix PA (Fidia Advanced Biopolymers, Abano Terme, Italy) has been used in our center on pediatric burned patients as a temporary dermal substitute to cover deep partial-thickness burns after dermabrasion. This "bridge" treatment was adopted to remove necrotic debris (dermabrasion) and to stimulate regeneration in a humid and protected environment (Hyalomatrix PA). We present results obtained with this approach. On the third to fifth day after admission, dermabrasion was practiced on deep burned areas, which were covered with Hyalomatrix PA. Change of dressings was performed every 7 days. On day 21, those areas still without signs of recovery were removed with classic escharectomy and covered with thin skin grafts. We treated 300 patients. Sixty-one percent needed only one dermabrasion treatment, 22.3% (67 patients) more than one, and 16.7% (50 patients) the classic escharectomy. A total of 83% of patients healed within 21 days. Our study suggests that the combination of dermabrasion with a temporary dermal substitute could be a good and feasible approach for treatment of deep partial-thickness burns. Prospective randomized studies are now necessary to compare our protocol with the gold standard treatment of topical dressings.

  20. Effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit.

    Science.gov (United States)

    Xi, Peng; Li, Yan; Ge, Xiaojin; Liu, Dandan; Miao, Mingsan

    2018-05-01

    Observing the effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit. We prepared boiling water scalded rabbits with deep II degree scald models and applied high, medium and low doses of nano-silver hydrogel coating film for different time and area. Then we compared the difference of burned paper weight before administration and after administration model burns, burn local skin irritation points infection, skin crusting and scabs from the time, and the impact of local skin tissue morphology. Rabbits deep II degree burn model successful modeling; on day 12, 18, high, medium and low doses of nano-silver hydrogel coating film significantly reduced skin irritation of rabbits infected with the integral value ( P  film group significantly decreased skin irritation, infection integral value ( P  film significantly reduced film rabbits' scalded skin crusting time ( P  film on the deep partial thickness burns has a significant therapeutic effect; external use has a significant role in wound healing.

  1. Transtendon, Double-Row, Transosseous-Equivalent Arthroscopic Repair of Partial-Thickness, Articular-Surface Rotator Cuff Tears

    OpenAIRE

    Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.

    2014-01-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-s...

  2. Scleral buckle infection by Serratia species

    Directory of Open Access Journals (Sweden)

    Ramesh Venkatesh

    2017-01-01

    Full Text Available We describe a rare case of scleral buckle (SB infection with Serratia species. A 48-year-old male with a history of retinal detachment repair with scleral buckling presented with redness, pain, and purulent discharge in the left eye for 4 days. Conjunctival erosion with exposure of the SB and scleral thinning was noted. The SB was removed and sent for culture. Blood and chocolate agar grew Gram-negative rod-shaped bacillus identified as Serratia marcescens. On the basis of the susceptibility test results, the patient was treated with oral and topical antibiotics. After 6 weeks of the treatment, his infection resolved.

  3. Scleral buckle infection by Serratia species.

    Science.gov (United States)

    Venkatesh, Ramesh; Agarwal, Manisha; Singh, Shalini; Mayor, Rahul; Bansal, Aditya

    2017-01-01

    We describe a rare case of scleral buckle (SB) infection with Serratia species. A 48-year-old male with a history of retinal detachment repair with scleral buckling presented with redness, pain, and purulent discharge in the left eye for 4 days. Conjunctival erosion with exposure of the SB and scleral thinning was noted. The SB was removed and sent for culture. Blood and chocolate agar grew Gram-negative rod-shaped bacillus identified as Serratia marcescens . On the basis of the susceptibility test results, the patient was treated with oral and topical antibiotics. After 6 weeks of the treatment, his infection resolved.

  4. ERK2 dependent signaling contributes to wound healing after a partial-thickness burn

    International Nuclear Information System (INIS)

    Satoh, Yasushi; Saitoh, Daizoh; Takeuchi, Atsuya; Ojima, Kenichiro; Kouzu, Keita; Kawakami, Saki; Ito, Masataka; Ishihara, Masayuki; Sato, Shunichi; Takishima, Kunio

    2009-01-01

    Burn healing is a complex physiological process involving multiple cell activities, such as cell proliferation, migration and differentiation. Although extracellular signal-regulated kinases (ERK) have a pivotal role in regulating a variety of cellular responses, little is known about the individual functions of ERK isoform for healing in vivo. This study investigated the role of ERK2 in burn healing. To assess this, Erk2 +/- mice generated by gene targeting were used. The resultant mice exhibited significant delay in re-epithelization of partial-thickness burns in the skin in comparison to wild-type. An in vitro proliferation assay revealed that keratinocytes from Erk2 +/- mice grew significantly slower than those prepared from wild-type. These results highlight the importance of ERK2 in the process of burn healing.

  5. Optimal treatment of partial thickness burns in children: a systematic review.

    Science.gov (United States)

    Vloemans, A F P M; Hermans, M H E; van der Wal, M B A; Liebregts, J; Middelkoop, E

    2014-03-01

    A large part of the patient population of a burn centre consists of children, most of whom are younger than four years. The majority of these young children suffer from superficial and deep partial thickness scald burns that may easily deepen to full thickness burns. A proper wound therapy, that prevents infection and ensures a moist wound condition, might prevent the deterioration of the wound. Therefore, we performed a systematic review of wound management and dressing materials to select the best treatment option for children with burns. A search in Medline and Embase revealed 51 articles for a critical appraisal. The articles were divided into randomized controlled trials, cohort studies and a group of case-reports. Total appraisal did not differ much amongst the groups; the level of evidence was highest in the randomized controlled trials and lowest in the case-reports. In 16 out of 34 comparative studies, silver sulfadiazine or a silver sulfadiazine/chlorhexidine-gluconate combination was the standard of wound care treatment. The competitor dressing was Biobrane(®) in six studies and amnion membrane in three. Tulle gauze, or tulle gauze impregnated with an antibacterial addition were the standard of care treatment in seven studies. In general, membranous dressings like Biobrane(®) and amnion membrane performed better than the standard of care on epithelialization rate, length of hospital stay and pain for treatment of partial thickness burns in children. However, hardly any of the studies investigated long-term results like scar formation. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  6. Effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit

    Directory of Open Access Journals (Sweden)

    Peng Xi

    2018-05-01

    Full Text Available Objective: Observing the effect of nano-silver hydrogel coating film on deep partial thickness scald model of rabbit. Method: We prepared boiling water scalded rabbits with deep II degree scald models and applied high, medium and low doses of nano-silver hydrogel coating film for different time and area. Then we compared the difference of burned paper weight before administration and after administration model burns, burn local skin irritation points infection, skin crusting and scabs from the time, and the impact of local skin tissue morphology. Result: Rabbits deep II degree burn model successful modeling; on day 12, 18, high, medium and low doses of nano-silver hydrogel coating film significantly reduced skin irritation of rabbits infected with the integral value (P < 0.01, P < 0.05; high, medium and low doses of nano-silver hydrogel coating film group significantly decreased skin irritation, infection integral value (P < 0.01, P < 0.05; high, medium and low doses of nano-silver hydrogel coating film significantly reduced film rabbits’ scalded skin crusting time (P < 0.01, significantly shortened the rabbit skin burns from the scab time (P < 0.01, and significantly improved the treatment of skin diseases in rabbits scald model change (P < 0.01, P < 0.05. Conclusion: The nano-silver hydrogel coating film on the deep partial thickness burns has a significant therapeutic effect; external use has a significant role in wound healing. Keywords: Nano-silver hydrogel coating film, Deep degree burns, Topical, Rabbits

  7. Estimating the time and temperature relationship for causation of deep-partial thickness skin burns.

    Science.gov (United States)

    Abraham, John P; Plourde, Brian; Vallez, Lauren; Stark, John; Diller, Kenneth R

    2015-12-01

    The objective of this study is to develop and present a simple procedure for evaluating the temperature and exposure-time conditions that lead to causation of a deep-partial thickness burn and the effect that the immediate post-burn thermal environment can have on the process. A computational model has been designed and applied to predict the time required for skin burns to reach a deep-partial thickness level of injury. The model includes multiple tissue layers including the epidermis, dermis, hypodermis, and subcutaneous tissue. Simulated exposure temperatures ranged from 62.8 to 87.8°C (145-190°F). Two scenarios were investigated. The first and worst case scenario was a direct exposure to water (characterized by a large convection coefficient) with the clothing left on the skin following the exposure. A second case consisted of a scald insult followed immediately by the skin being washed with cool water (20°C). For both cases, an Arrhenius injury model was applied whereby the extent and depth of injury were calculated and compared for the different post-burn treatments. In addition, injury values were compared with experiment data from the literature to assess verification of the numerical methodology. It was found that the clinical observations of injury extent agreed with the calculated values. Furthermore, inundation with cool water decreased skin temperatures more quickly than the clothing insulating case and led to a modest decrease in the burn extent. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  8. Scleral buckle infection with Alcaligenes xylosoxidans

    Directory of Open Access Journals (Sweden)

    Chih-Kang Hsu

    2014-01-01

    Full Text Available We describe a rare case of extraocular inflammation secondary to scleral buckle infection with Alcaligenes xylosoxidans. A 60-year-old female with a history of retinal detachment repair with open-book technique of scleral buckling presented with purulent discharge and irritation in the right eye that had begun 4 weeks earlier and had been treated ineffectively at another hospital. Conjunctival erosion with exposure of the scleral buckle was noted. The scleral buckle was removed and cultured. The explanted material grew gram-negative rod later identified as A. xylosoxidans. On the basis of the susceptibility test results, the patient was treated by subconjunctival injection and fortified topical ceftazidime. After 4 weeks of treatment, the infection resolved.

  9. Objective and subjective performance of scleral lenses and new advances in scleral lens technologies

    NARCIS (Netherlands)

    Visser, E.S.

    2015-01-01

    Scleral lenses are widely recognized for their ability to markedly improve quality of life and giving back patients their ability to perform daily activities, mainly as a result of restoring visual function and/or reduction of ocular discomfort and pain.Scleral lenses are an important front-line

  10. Adenosine triphosphate hydrolysis reduces neutrophil infiltration and necrosis in partial-thickness scald burns in mice.

    Science.gov (United States)

    Bayliss, Jill; Delarosa, Sara; Wu, Jianfeng; Peterson, Jonathan R; Eboda, Oluwatobi N; Su, Grace L; Hemmila, Mark; Krebsbach, Paul H; Cederna, Paul S; Wang, Stewart C; Xi, Chuanwu; Levi, Benjamin

    2014-01-01

    Extracellular adenosine triphosphate (ATP), present in thermally injured tissue, modulates the inflammatory response and causes significant tissue damage. The authors hypothesize that neutrophil infiltration and ensuing tissue necrosis would be mitigated by removing ATP-dependent signaling at the burn site. Mice were subjected to 30% TBSA partial-thickness scald burn by dorsal skin immersion in a water bath at 60 or 20°C (nonburn controls). In the treatment arm, an ATP hydrolyzing enzyme, apyrase, was applied directly to the site immediately after injury. Skin was harvested after 24 hours and 5 days for hematoxylin and eosin stain, elastase, and Ki-67 staining. Tumor necrosis factor (TNF)-α and interferon (IFN)-β expression were measured through quantitative real-time polymerase chain reaction. At 24 hours, the amount of neutrophil infiltration was different between the burn and burn + apyrase groups (P burn group at 24 hours and 5 days. TNF-α and IFN-β expression at 24 hours in the apyrase group was lower than in the burn group (P burn site allays the neutrophil response to thermal injury and reduces tissue necrosis. This decrease in inflammation and tissue necrosis is at least partially because of TNF-α and IFN-β signaling. Apyrase could be used as topical inflammatory regulators to quell the injury caused by inflammation.

  11. Scleral topography analysed by optical coherence tomography.

    Science.gov (United States)

    Bandlitz, Stefan; Bäumer, Joachim; Conrad, Uwe; Wolffsohn, James

    2017-08-01

    A detailed evaluation of the corneo-scleral-profile (CSP) is of particular relevance in soft and scleral lenses fitting. The aim of this study was to use optical coherence tomography (OCT) to analyse the profile of the limbal sclera and to evaluate the relationship between central corneal radii, corneal eccentricity and scleral radii. Using OCT (Optos OCT/SLO; Dunfermline, Scotland, UK) the limbal scleral radii (SR) of 30 subjects (11M, 19F; mean age 23.8±2.0SD years) were measured in eight meridians 45° apart. Central corneal radii (CR) and corneal eccentricity (CE) were evaluated using the Oculus Keratograph 4 (Oculus, Wetzlar, Germany). Differences between SR in the meridians and the associations between SR and corneal topography were assessed. Median SR measured along 45° (58.0; interquartile range, 46.8-84.8mm) was significantly (ptopography and may provide additional data useful in fitting soft and scleral contact lenses. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. Effect of Extracorporeal Shock Wave Treatment on Deep Partial-Thickness Burn Injury in Rats: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Gabriel Djedovic

    2014-01-01

    Full Text Available Extracorporeal shock wave therapy (ESWT enhances tissue vascularization and neoangiogenesis. Recent animal studies showed improved soft tissue regeneration using ESWT. In most cases, deep partial-thickness burns require skin grafting; the outcome is often unsatisfactory in function and aesthetic appearance. The aim of this study was to demonstrate the effect of ESWT on skin regeneration after deep partial-thickness burns. Under general anesthesia, two standardized deep partial-thickness burns were induced on the back of 30 male Wistar rats. Immediately after the burn, ESWT was given to rats of group 1 (N=15, but not to group 2 (N=15. On days 5, 10, and 15, five rats of each group were analyzed. Reepithelialization rate was defined, perfusion units were measured, and histological analysis was performed. Digital photography was used for visual documentation. A wound score system was used. ESWT enhanced the percentage of wound closure in group 1 as compared to group 2 (P<0.05. The reepithelialization rate was improved significantly on day 15 (P<0.05. The wound score showed a significant increase in the ESWT group. ESWT improves skin regeneration of deep partial-thickness burns in rats. It may be a suitable and cost effective treatment alternative in this type of burn wounds in the future.

  13. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    Science.gov (United States)

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally

  14. [Clinical study and pathological examination on the treatment of deep partial thickness burn wound with negative charge aerosol].

    Science.gov (United States)

    Li, Tian-zeng; Xu, Ying-bin; Hu, Xiao-gen; Shen, Rui; Peng, Xiao-dong; Wu, Wei-jiang; Luo, Lan; Dai, Xin-ming; Zou, Yong-tong; Qi, Shao-hai; Wu, Li-ping; Xie, Ju-lin; Deng, Xiao-xin; Chen, E; Zhang, Hui-Zhen

    2005-08-01

    To investigate the effect of negative charge aerosol (NCA) on the treatment of burn wound. Patients with superficial or deep partial thickness burn only were enrolled in the study, and they were randomly divided into trial group (T, including 180 cases of superficial thickness burn and 100 cases of deep partial thickness burn), control group (C, including 30 cases with superficial thickness burn and 30 with deep partial thickness burn), and self control group (SC, including 10 cases with superficial thickness burn and 10 with deep partial thickness burn). The patients in T and SC groups were treated with NCA for 1.5 hours, 1-2 times a day, from 6 postburn hour (PBH) to 2 postburn day (PBD), while those in C group received conventional treatment. For those in SC group, some of the wounds were covered with sterile schissel, while other wounds without schissel covering. The general changes in the wounds during NCA treatment were observed, and bacterial culture before and after NCA treatment was performed. The healing time was recorded and the blood biochemical parameters were determined. Rat model with deep partial thickness scald was established, and the rats were also divided into T and C groups, and received treatment as in human. Tissue samples were harvested from the wounds of rats in the 2 groups before and 1, 2, 3 weeks after treatment for pathological examination. There was no infection and little exudation in the patients in T group. No bacteria were found in the wound before and after NCA treatment. The healing time of the wounds of patients with superficial and deep partial thickness burn in T group was 6.3 +/- 1.6 d and 15.1 +/- 3.1 d, respectively, which was obviously shorter than those in C group (11.3 +/- 1.4 d and 21.2 +/- 1.4 d, P Negative charge aerosol is safe and effective in promoting wound healing of the patients with partial thickness burns.

  15. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    Science.gov (United States)

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be

  16. Scleral Buckle Infection With Pseudallescheria boydii.

    Science.gov (United States)

    Law, Janice C; Breazzano, Mark P; Eliott, Dean

    2017-08-01

    Pseudallescheria boydii is a ubiquitous fungus that infects soft tissues and is known to cause ocular disease, including keratitis and endophthalmitis, in rare cases. In immunocompromised hosts, P. boydii can disseminate to or from the eye and other organs with lethal consequences. Postoperative P. boydii infections have, in rare cases, complicated several types of ocular surgeries in immunocompetent patients, but never for a scleral buckle. The authors present the first case of an infected scleral buckle from P. boydii. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:676-678.]. Copyright 2017, SLACK Incorporated.

  17. 21 CFR 886.3800 - Scleral shell.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Scleral shell. 886.3800 Section 886.3800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... device made of glass or plastic that is intended to be inserted for short time periods over the cornea...

  18. Transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears.

    Science.gov (United States)

    Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D

    2014-10-01

    Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.

  19. Partial-thickness macular hole in vitreomacular traction syndrome: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Al Sabti Khalid

    2010-01-01

    Full Text Available Abstract Introduction Vitreomacular traction syndrome has recently been recognized as a distinct clinical condition. It may lead to many complications, such as cystoid macular edema, macular pucker formation, tractional macular detachment, and full-thickness macular hole formation. Case presentation We report a case of vitreomacular traction syndrome with eccentric traction at the macula and a partial-thickness macular hole in a 63-year-old Pakistani Punjabi man. The patient was evaluated using optical coherence tomography, and he underwent a successful pars plana vitrectomy. After the operation, his foveal contour regained normal configuration, and his visual acuity improved from 20/60 to 20/30. Conclusions Pars plana vitrectomy prevents the progression of a partial thickness macular hole in vitreomacular traction syndrome. The relief of traction by vitrectomy restores foveal anatomy and visual acuity in this condition.

  20. Comparison of three different dressings for partial thickness burns in children: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Gee Kee, Emma; Kimble, Roy M; Cuttle, Leila; Stockton, Kellie

    2013-11-25

    In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat™, Acticoat™ combined with Mepitel™ and Mepilex Ag™ dressings for acute, paediatric partial thickness burns. Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of ≤ 10% will be eligible for the trial. Patients will be randomised to one of the three dressing groups: (1) Acticoat™ or (2) Acticoat™ combined with Mepitel™ or (3) Mepilex Ag™. A minimum of 28 participants will be recruited for each treatment group. Primary measures of pain, distress and healing will be repeated at each dressing change until complete wound re-epithelialisation occurs or skin grafting is required. Additional data collected will include infection status at each dressing change, physical function, scar outcome and scar management requirements, cost effectiveness of each dressing and staff perspectives of the dressings. The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. Australian New Zealand Clinical Trials Registry ACTRN12613000105741.

  1. [Efficacy observation on application of negative pressure therapy in the treatment of superficial partial-thickness scald wound in children].

    Science.gov (United States)

    Shen, Chuan-an; Chai, Jia-ke; Tuo, Xiao-ye; Cai, Jian-hua; Li, Dong-jie; Zhang, Lin; Zhu, Hua; Cai, Jin-dong

    2013-02-01

    To observe the effect of negative pressure therapy in the treatment of superficial partial-thickness scald in children. Three hundred and seven children with superficial partial-thickness scald hospitalized from August 2009 to May 2012 were divided into negative pressure therapy group (NPT, n = 145) and control group (C, n = 162) according to the random number table. Patients in group NPT were treated with negative pressure from within post injury day (PID) 3 to PID 9 (with -16 kPa pressure), while traditional occlusive dressing method was used in group C. Changes in body temperature, wound healing condition, frequency of dressing change were compared between group NPT and group C. Bacterial culture results of wounds were compared before and after treatment in group NPT. Volume of drained transudate per one percent of wound area was recorded in group NPT on PID 1 to PID 3. Data were processed with t test or chi-square test. The incidence of high fever was significantly lower in group NPT (26.9%, 39/145) than in group C (63.6%, 103/162, χ(2) = 41.419, P partial-thickness scald.

  2. Impact of a Newly Implemented Burn Protocol on Surgically Managed Partial Thickness Burns at a Specialized Burns Center in Singapore.

    Science.gov (United States)

    Tay, Khwee-Soon Vincent; Chong, Si-Jack; Tan, Bien-Keem

    2016-03-01

    This study evaluated the impact of a newly implemented protocol for superficial to mid-dermal partial thickness burns which involves early surgery and rapid coverage with biosynthetic dressing in a specialized national burns center in Singapore. Consecutive patients with 5% or greater total body surface area (TBSA) superficial to mid-dermal partial thickness burns injury admitted to the Burns Centre at the Singapore General Hospital between August and December 2014 for surgery within 48 hours of injury were prospectively recruited into the study to form the protocol group. Comparable historical cases from the year 2013 retrieved from the burns center audit database were used to form the historical control group. Demographics (age, sex), type and depth of burns, %TBSA burnt, number of operative sessions, and length of stay were recorded for each patient of both cohorts. Thirty-nine burns patients managed under the new protocol were compared with historical control (n = 39) comparable in age and extensiveness of burns. A significantly shorter length of stay (P burns was observed in the new protocol group (0.74 day/%TBSA) versus historical control (1.55 day/%TBSA). Fewer operative sessions were needed under the new protocol for burns 10% or greater TBSA burns (P protocol for surgically managed burns patients which involves early surgery and appropriate use of biosynthetic dressing on superficial to mid-dermal partial thickness burns. Clinically, shorter lengths of stay, fewer operative sessions, and decreased need for skin grafting of burns patient were observed.

  3. INTRACORNEAL AND SCLERAL CYST FOLLOWING CATARACT EXTRACTION

    Directory of Open Access Journals (Sweden)

    Gabriel van Rij

    2002-12-01

    Full Text Available Background. A six-year-old boy presented with a large progressive intracorneal and scleral cyst. Two years before, bilateral cataract surgery through a 6.5-mm corneal incision was performed elsewhere.Methods. The posterior wall of the cyst could be excised, as well as the anterior wall in the sclera. Upon histo-pathology the cyst wall was lined by epithelium. The epithelial cells of the anterior side in the cornea were removed with a curette and a corpus alienum drill. Three and a half years after removal of the cyst, there was no recurrence. Visual acuity was 0.8. Conclusions. An intracorneal and scleral inclusion cyst was successfully removed by surgical excision and the removal of epithelial cells by a curette and a corpus alienum drill.

  4. Scleral Biomechanics in the Aging Monkey Eye

    Science.gov (United States)

    Girard, Michaël J. A.; Suh, J-K. Francis; Bottlang, Michael; Burgoyne, Claude F.; Downs, J. Crawford

    2010-01-01

    Purpose To investigate the age-related differences in the inhomogeneous, anisotropic, nonlinear biomechanical properties of posterior sclera from old (22.9 ± 5.3 years) and young (1.5 ± 0.7 years) rhesus monkeys. Methods The posterior scleral shell of each eye was mounted on a custom-built pressurization apparatus, then intraocular pressure (IOP) was elevated from 5 to 45 mmHg while the 3D displacements of the scleral surface were measured using speckle interferometry. Each scleral shell geometry was digitally reconstructed from data generated by a 3D digitizer (topography) and 20 MHz ultrasounds (thickness). An inverse finite element (FE) method incorporating a fiber-reinforced constitutive model was used to extract a unique set of biomechanical properties for each eye. Displacements, thickness, stress, strain, tangent modulus, structural stiffness, and preferred collagen fiber orientation were mapped for each posterior sclera. Results The model yielded 3-D deformations of posterior sclera that matched well with those observed experimentally. The posterior sclera exhibited inhomogeneous, anisotropic, nonlinear mechanical behavior. The sclera was significantly thinner (p = 0.038), and tangent modulus and structural stiffness were significantly higher in old monkeys (p biomechanics, and potentially contribute to age-related susceptibility to glaucomatous vision loss. PMID:19494203

  5. Intramembranous ossification of scleral ossicles in Chelydra serpentina.

    Science.gov (United States)

    Franz-Odendaal, Tamara A

    2006-01-01

    Scleral ossicles are present in many reptiles, including turtles and birds. In both groups the sclerotic ring situated in the eye is composed of a number of imbricating scleral ossicles or plates. Despite this gross morphological similarity, Andrews (1996. An endochondral rather than a dermal origin for scleral ossicles in Cryptodiran turtles. J. Herpetol. 30, 257-260) reported that the scleral ossicles of turtles develop endochondrally unlike those in birds, which develop intramembranously after a complex epithelial-mesenchymal inductive event. This study re-explores one of the species examined by Andrews in order to determine the mode of ossification of scleral ossicles in turtles. A growth series of Chelydra serpentina embryos, including the stages examined by Andrews, were examined by staining separately for cartilage and bone. Results clearly contradict Andrews (1996) and show that the scleral ossicles of Chelydra serpentina develop similarly to those in birds. That is, they develop intramembranously without a cartilage precursor and are likely induced by transient scleral papillae. The sequence of scleral papillae development is broadly similar, but the papillae themselves are not as distinct as those seen in chicken embryos. This study has important consequences for understanding the homology of scleral ossicles among tetrapods.

  6. Cost-effectiveness of silver dressings for paediatric partial thickness burns: An economic evaluation from a randomized controlled trial.

    Science.gov (United States)

    Gee Kee, E; Stockton, K; Kimble, R M; Cuttle, L; McPhail, S M

    2017-06-01

    Partial thickness burns of up to 10% total body surface area (TBSA) in children are common injuries primarily treated in the outpatient setting using expensive silver-containing dressings. However, economic evaluations in the paediatric burns population are lacking to assist healthcare providers when choosing which dressing to use. The aim of this study was to conduct a cost-effectiveness analysis of three silver dressings for partial thickness burns ≤10% TBSA in children aged 0-15 years using days to full wound re-epithelialization as the health outcome. This study was a trial based economic evaluation (incremental cost effectiveness) conducted from a healthcare provider perspective. Ninety-six children participated in the trial investigating Acticoat™, Acticoat™ with Mepitel™ or Mepilex Ag™. Costs directly related to the management of partial thickness burns ≤10% TBSA were collected during the trial from March 2013 to July 2014 and for a one year after re-epithelialization time horizon. Incremental cost effectiveness ratios were estimated and dominance probabilities calculated from bootstrap resampling trial data. Sensitivity analyses were conducted to examine the potential effect of accounting for infrequent, but high cost, skin grafting surgical procedures. Costs (dressing, labour, analgesics, scar management) were considerably lower in the Mepilex Ag™ group (median AUD$94.45) compared to the Acticoat™ (median $244.90) and Acticoat™ with Mepitel™ (median $196.66) interventions. There was a 99% and 97% probability that Mepilex Ag™ dominated (cheaper and more effective than) Acticoat™ and Acticoat™ with Mepitel™, respectively. This pattern of dominance was consistent across raw cost and effects, after a priori adjustments, and sensitivity analyses. There was an 82% probability that Acticoat™ with Mepitel dominated Acticoat™ in the primary analysis, although this probability was sensitive to the effect of skin graft procedures. This

  7. Random Pattern Vertically Oriented, Partial Thickness Buccinator Myomucosal Flap for Intraoral Reconstruction: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Amin Rahpeyma

    2016-05-01

    Full Text Available Introduction: Reconstruction of the oral cavity witha flap design containing the buccal mucosa and buccinator muscle but excluding the facial artery and vein is the topic of these case reports. Case Reports: This article uses random pattern vertically oriented partial thickness buccinator myomucosal flap for intraoral reconstruction in two cases. The first was for lining the mandibular anterior vestibule in a trauma patient. The second was for oral side coverage of bone graft in special cleft patient. In both patients, this flap survived and good bone coverage with non-keratinized mucosa was obtained. Conclusion:  Thin long buccal myomucosal flap not including facial artery and vein can survive.

  8. Scleral lens tolerance after corneal cross-linking for keratoconus

    NARCIS (Netherlands)

    Visser, Esther Simone; Soeters, Nienke; Tahzib, Nayyirih G.

    2015-01-01

    Purpose. Subjective and objective evaluation of scleral lens tolerance and fitting before and after corneal cross-linking (CXL) for progressive keratoconus. Methods. In this prospective cohort, evaluations were made of 18 unilateral eyes in patients who underwent CXL and had been wearing scleral

  9. Comparison of Laser Doppler Imaging (LDI) and clinical assessment in differentiating between superficial and deep partial thickness burn wounds.

    Science.gov (United States)

    Jan, Saadia Nosheen; Khan, Farid Ahmed; Bashir, Muhammad Mustehsan; Nasir, Muneeb; Ansari, Hamid Hussain; Shami, Hussan Birkhez; Nazir, Umer; Hanif, Asif; Sohail, Muhammad

    2018-03-01

    To compare the accuracy of Laser Doppler Imaging (LDI) and clinical assessment in differentiating between superficial and deep partial thickness burns to decide whether early tangential excision and grafting or conservative management should be employed to optimize burn and patient management. March 2015 to November 2016. Ninety two wounds in 34 patients reporting within 5days of less than 40% burn surface area were included. Unstable patients, pregnant females and those who expired were excluded. The wounds were clinically assessed and LDI done concomitantly Plastic Surgeons blinded to each other's findings. Wound appearance, color, blanching, pain, hair follicle dislodgement were the clinical parameters that distinguished between superficial and deep partial thickness burns. On day 21, the wounds were again assessed for the presence of healing by the same plastic surgeons. The findings were correlated with the initial findings on LDI and clinical assessment and the results statistically analyzed. The data of 92 burn wounds was analyzed using SPSS (ver. 17). Clinical assessment correctly identified the depth of 75 and LDI 83 wounds, giving diagnostic accuracies of 81.52% and 90.21% respectively. The sensitivity of clinical assessment was 81% and of LDI 92.75%, whereas the specificity was 82% for both. The positive predictive value was 93% for clinical assessment and 94% for LDI while the negative predictive value was 59% and 79% respectively. Predictive accuracy of LDI was found to be better than clinical assessment in the prediction of wound healing, the gold standard for wound healing being 21 days. As such it can prove to be a reliable and viable cost effective alternative per se to clinical assessment. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  10. Endoilluminator-assisted scleral buckling: Our results

    Directory of Open Access Journals (Sweden)

    Varun Gogia

    2014-01-01

    Full Text Available Aims: The aim was to evaluate the long-term surgical outcomes of endoillumination assisted scleral buckling (EASB in primary rhegmatogenous retinal detachment (RRD. Methods: Twenty-five eyes of 25 patients with primary RRD and proliferative vitreoretinopathy ≤C2 where any preoperative break could not be localised, were included. All patients underwent 25 gauge endoilluminator assisted rhegma localisation. Successful break determination was followed by cryopexy and standard scleral buckling under surgical microscope. Anatomical and functional outcomes were evaluated at the end of 2 years. Results: At least one intraoperative break could be localized in 23 of 25 (92% eyes. Median age of these patients was 46 years (range: 17-72. Thirteen eyes (56.52% were phakic, 8 (34.78% were pseudophakic and 2 (8.6% were aphakic. Anatomical success (attachment of retina was achieved in 22 (95.63% of 23 eyes with EASB. All eyes remained attached at the end of 2 years. Significant improvement in mean visual acuity (VA was achieved at the end of follow-up (1.09 ± 0.46 log of the minimum angle of resolution [logMAR] compared with preoperative VA (1.77 ± 0.28 logMAR (P < 0.001. Conclusion: EASB can be considered an effective alternative to vitreoretinal surgery in simple retinal detachment cases with the added advantage of enhanced microscopic magnification and wide field illumination.

  11. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: Accuracy, and inter- and intra-observer agreements

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Ahn, Myeong Im; Kim, Yang-Soo

    2010-01-01

    Background: Partial-thickness tear of the rotator cuff is a common cause of shoulder pain. Magnetic resonance (MR) arthrography has been described as a useful measure to diagnose rotator cuff abnormalities. Purpose: To determine the reliability and accuracy of MR arthrography with abduction and external rotation (ABER) view for the diagnosis of partial-thickness tears of the rotator cuff. Material and Methods: Among patients who underwent MR arthrographies, 22 patients (12 men, 10 women; mean age 45 years) who had either partial-thickness tear or normal tendon on arthroscopy were included. MR images were independently scored by two observers for partial-thickness tears of the rotator cuff. Interobserver and intraobserver agreements for detection of partial-thickness tears of the rotator cuff were calculated by using κ coefficients. The differences in areas under the receiver operating characteristic (ROC) curves were assessed with a univariate Z-score test. Differences in sensitivity and specificity for interpretations based on different imaging series were tested for significance using the McNemar statistic. Results: Sensitivity, specificity, and accuracy of each reader on MR imaging without ABER view were 83%, 90%, and 86%, and 83%, 80%, and 82%, respectively, whereas on overall interpretation including ABER view, the sensitivity, specificity, and accuracy of each reader were 92%, 70%, and 82%, and 92%, 80%, and 86%, respectively. Including ABER view, interobserver agreement for partial-thickness tear increased from κ=0.55 to κ=0.68. Likewise, intraobserver agreements increased from κ=0.79 and 0.53 to κ=0.81 and 0.70 for each reader, respectively. The areas under the ROC curves for each reader were 0.96 and 0.90, which were not significantly different. Conclusion: Including ABER view in routine sequences of MR arthrography increases the sensitivity, and inter- and intraobserver agreements for detecting partial-thickness tear of rotator cuff tendon

  12. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: Accuracy, and inter- and intra-observer agreements

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Ahn, Myeong Im (Dept. of Radiology, Seoul St. Mary' s Hospital, School of Medicine, Catholic Univ. of Korea, Seoul (Korea)), e-mail: whjee@catholic.ac.kr; Kim, Yang-Soo (Dept. of Orthopedic Surgery, Seoul St. Mary' s Hospital, School of Medicine, Catholic Univ. of Korea, Seoul (Korea))

    2010-03-15

    Background: Partial-thickness tear of the rotator cuff is a common cause of shoulder pain. Magnetic resonance (MR) arthrography has been described as a useful measure to diagnose rotator cuff abnormalities. Purpose: To determine the reliability and accuracy of MR arthrography with abduction and external rotation (ABER) view for the diagnosis of partial-thickness tears of the rotator cuff. Material and Methods: Among patients who underwent MR arthrographies, 22 patients (12 men, 10 women; mean age 45 years) who had either partial-thickness tear or normal tendon on arthroscopy were included. MR images were independently scored by two observers for partial-thickness tears of the rotator cuff. Interobserver and intraobserver agreements for detection of partial-thickness tears of the rotator cuff were calculated by using kappa coefficients. The differences in areas under the receiver operating characteristic (ROC) curves were assessed with a univariate Z-score test. Differences in sensitivity and specificity for interpretations based on different imaging series were tested for significance using the McNemar statistic. Results: Sensitivity, specificity, and accuracy of each reader on MR imaging without ABER view were 83%, 90%, and 86%, and 83%, 80%, and 82%, respectively, whereas on overall interpretation including ABER view, the sensitivity, specificity, and accuracy of each reader were 92%, 70%, and 82%, and 92%, 80%, and 86%, respectively. Including ABER view, interobserver agreement for partial-thickness tear increased from kappa=0.55 to kappa=0.68. Likewise, intraobserver agreements increased from kappa=0.79 and 0.53 to kappa=0.81 and 0.70 for each reader, respectively. The areas under the ROC curves for each reader were 0.96 and 0.90, which were not significantly different. Conclusion: Including ABER view in routine sequences of MR arthrography increases the sensitivity, and inter- and intraobserver agreements for detecting partial-thickness tear of rotator cuff

  13. Neck and scleral hemorrhage in drowning.

    Science.gov (United States)

    Alexander, Russell T; Jentzen, Jeffrey M

    2011-03-01

    The determination of the cause and manner of death for a body recovered from the water can be difficult because of a lack of autopsy findings specific for drowning. This case report describes a 30-year-old man found submerged at the bottom of a hotel pool. An autopsy revealed scleral hemorrhages and fascial hemorrhages of multiple muscles of the anterior and posterior neck bilaterally. No evidence of traumatic injury was on the surface of the body. An investigation by law enforcement found no evidence of foul play. The occurrence of petechial and neck hemorrhage in a body recovered from the water is controversial, and a review of this literature will be given. We suggest that fascial hemorrhages of the muscles of the neck, as well as cephalic hemorrhages, can be explained by drowning-related elevated central venous pressure that is communicated to the head through the valveless veins of the neck. © 2010 American Academy of Forensic Sciences.

  14. Bilateral streptococcal corneoscleritis complicating β irradiation induced scleral necrosis

    International Nuclear Information System (INIS)

    Moriarty, A.P.; Crawford, G.J.; McAllister, I.L.; Constable, I.J.

    1993-01-01

    Bacterial corneoscleritis may complicate scleral necrosis induced by β irradiation following pterygium removal. Previous cases have been unilateral. The authors report a case of severe bilateral corneoscleritis caused by Streptococcus pneumoniae. (author)

  15. Full and Partial Thickness Burns from Spontaneous Combustion of E-Cigarette Lithium-Ion Batteries with Review of Literature.

    Science.gov (United States)

    Treitl, Daniela; Solomon, Rachele; Davare, Dafney L; Sanchez, Rafael; Kiffin, Chauniqua

    2017-07-01

    In recent years, the use of electronic cigarettes (e-cigarettes) has increased worldwide. Most electronic nicotine delivery systems use rechargeable lithium-ion batteries, which are relatively safe, but in rare cases these batteries can spontaneously combust, leading to serious full and partial thickness burn injuries. Explosions from lithium-ion batteries can cause a flash fire and accelerant-related burn injuries. A retrospective chart review was conducted of 3 patients with lithium-ion battery burns seen at our Level I community-based trauma center. Clinical presentation, management, and outcome are presented. All 3 patients sustained burn injuries (total body surface area range 5-13%) from the spontaneous combustion of lithium-ion batteries used for e-cigarettes. All patients were treated with debridement and local wound care. All fully recovered without sequelae. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians can expect to treat burn cases due to spontaneous lithium-ion battery combustion as e-cigarette use continues to increase. The cases presented here are intended to bring attention to lithium-ion battery-related burns, prepare physicians for the clinical presentation of this burn mechanism, and facilitate patient education to minimize burn risk. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Topical silver sulfadiazine vs collagenase ointment for the treatment of partial thickness burns in children: a prospective randomized trial.

    Science.gov (United States)

    Ostlie, Daniel J; Juang, David; Aguayo, Pablo; Pettiford-Cunningham, Janine P; Erkmann, Erin A; Rash, Diane E; Sharp, Susan W; Sharp, Ronald J; St Peter, Shawn D

    2012-06-01

    The 2 most commonly used topical agents for partial thickness burns are silver sulfadiazine (SSD) and collagenase ointment (CO). Silver sulfadiazine holds antibacterial properties, and eschar separation occurs naturally. Collagenase ointment is an enzyme that cleaves denatured collagen facilitating separation but has no antibacterial properties. Currently, there are no prospective comparative data in children for these 2 agents. Therefore, we conducted a prospective randomized trial. After institutional review board approval, patients were randomized to daily debridement with SSD or CO. Primary outcome was the need for skin grafting. Patients were treated for 2 days with SSD with subsequent randomization. Polymyxin was mixed with CO for antibacterial coverage. Debridements were performed daily for 10 days or until the burn healed. Grafting was performed after 10 days if not healed. From January 2008 to January 2011, 100 patients were enrolled, with no differences in patient characteristics. There were no differences in clinical course, outcome, or need for skin grafting. Wound infections occurred in 7 patients treated with CO and 1 patient treated with SSD (P = .06). Collagenase ointment was more expensive than SSD (P burns results. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Partial-thickness burn wounds healing by topical treatment: A randomized controlled comparison between silver sulfadiazine and centiderm.

    Science.gov (United States)

    Saeidinia, Amin; Keihanian, Faeze; Lashkari, Ardalan Pasdaran; Lahiji, Hossein Ghavvami; Mobayyen, Mohammadreza; Heidarzade, Abtin; Golchai, Javad

    2017-03-01

    Burns are common event and associated with a high incidence of death, disability, and high costs. Centella asiatica (L.) is a medicinal herb, commonly growing in humid areas in several tropical countries that improve wound healing. On the basis of previous studies, we compared the efficacy of Centiderm versus silver sulfadiazine (SSD) in partial thickness burning patients. Study population comprised burn victims referred to Velayat Burning Hospital at Rasht, Iran. The intervention group received Centiderm and control group SSD cream. Burn wounds were treated once daily at home. All of the wounds were evaluated till complete healing occurred and at the admission, days 3, 7, 14 objective signs; visual acuity score (VAS) and subjective signs were recorded. Re-epithelialization time and complete healing days were recorded. We used random fixed block for randomization. The randomization sequence was created using the computer. Patients and burning specialist physician were blinded. Seventy-five patients randomized into 2 groups; (40 patients: Centiderm group; 35 patients: SSD group). The mean age of them was 30.67 ± 9.91 years and 19 of them were male (31.7%). Thirty patients in Centiderm and 30 patients in SSD group were analyzed. All of objective and subjective signs and mean of re-epithelialization and complete healing were significantly better in Centiderm group rather than SSD group (P < 0.05). There was no infection in Centiderm group. We showed that use of Centiderm ointment not only improved the objective and subjective signs in less than 3 days, but also the re-epithelialization and complete healing rather than SSD without any infection in the subjects.

  18. Arthroscopic repair of partial-thickness and small full-thickness rotator cuff tears: tendon quality as a prognostic factor for repair integrity.

    Science.gov (United States)

    Chung, Seok Won; Kim, Jae Yoon; Yoon, Jong Pil; Lyu, Seong Hwa; Rhee, Sung Min; Oh, Se Bong

    2015-03-01

    The healing failure rate is high for partial-thickness or small full-thickness rotator cuff tears. To retrospectively evaluate and compare outcomes after arthroscopic repair of high-grade partial-thickness and small full-thickness rotator cuff tears and factors affecting rotator cuff healing. Cohort study; Level of evidence, 3. Included in the study were 55 consecutive patients (mean age, 57.9 ± 7.2 years) who underwent arthroscopic repair for high-grade partial-thickness (n = 34) and small full-thickness (n = 21) rotator cuff tears. The study patients also underwent magnetic resonance imaging (MRI) preoperatively and computed tomography arthrography (CTA) at least 6 months postoperatively, and their functional outcomes were evaluated preoperatively and at the last follow-up (>24 months). All partial-thickness tears were repaired after being converted to full-thickness tears; thus, the repair process was almost the same as for small full-thickness tears. The tendinosis of the torn tendon was graded from the MRI images using a 4-point scale, and the reliabilities were assessed. The outcomes between high-grade partial-thickness tears that were converted to small full-thickness tears and initially small full-thickness tears were compared, and factors affecting outcomes were evaluated. The inter- and intraobserver reliabilities of the tendinosis grade were good (intraclass correlation coefficient, 0.706 and 0.777, respectively). Failure to heal as determined by CTA was observed in 12 patients with a high-grade partial-thickness tear (35.3%; complete failure in 4 and partial failure in 8) and in 3 patients with a small full-thickness tear (14.3%; complete failure in 1 and partial failure in 2). The patients with high-grade partial-thickness rotator cuff tears showed a higher tendinosis grade than did those with small full-thickness tears (P = .014), and the severity of the tendinosis was related to the failure to heal (P = .037). Tears with a higher tendinosis grade

  19. Role of mini-scleral lens in mucous membrane pemphigoid

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar

    2017-01-01

    Full Text Available This study aims to report the use of mini-scleral contact lens in the management of mucous membrane pemphigoid (MMP with persistent epithelial defects. A 68-year-old male with a history of ocular pain and declining visual acuity was referred to our clinic with a diagnosis of MMP. His corrected distance visual acuity (CDVA was 20/200 in the right eye and 20/100 in the left eye. Despite being on lubricants, topical steroids and intravenous cyclophosphamide, the patient developed persistent corneal epithelial defects in both eyes. He was then given a trial of mini-scleral lenses. Within 4 weeks, corneal epithelial defects healed, and at 6 months, the CDVA had improved to 20/50 in the right eye and 20/40 in the left eye. By improving the corneal surface integrity and visual function, mini-scleral lenses can play a role in the visual rehabilitation of patients with MMP.

  20. Scleral electrocautery and its effects on choroid vessels: implications for subretinal fluid drainage during scleral buckling surgery.

    Science.gov (United States)

    Roybal, C Nathaniel; Tsui, Irena; Sanfilippo, Christian; Hubschman, Jean-Pierre

    2013-01-01

    External drainage of subretinal fluid as part of a scleral buckling procedure rapidly restores the retinal pigment epithelium-neural retina interface in rhegmatogenous retinal detachments but carries the inherent risk of subretinal hemorrhage and retinal incarceration. The authors investigated variations to the technique to reduce the chance of subretinal hemorrhage originating from the choroid. A novel method for needle drainage using electrocautery of the sclerochoroidal layers before puncture was employed. The effect of 0% to 50% scleral electrocautery in a porcine model was investigated. A significant decrease in choroidal vessel diameter and choroidal vessel density at 40% electrocautery was demonstrated. Electrocautery without scleral cut-down before external drainage of subretinal fluid likely decreases the chance of subretinal hemorrhage by decreasing choroidal vascularity. Copyright 2013, SLACK Incorporated.

  1. Management of Perforated Mooren's Ulcer with a Rotational Scleral ...

    African Journals Online (AJOL)

    A case of bilateral Mooren's ulcer with corneal melting and uveal prolapse in the left eye (LE) involving 1½ h was managed with a scleral rotational autograft at the Rachel Eye Center, Abuja. The patient was a 75‑year‑old female retiree with concomitant rheumatoid arthritis involving the knee and metacarpophalangeal joints ...

  2. Management of Perforated Mooren's Ulcer with a Rotational Scleral ...

    African Journals Online (AJOL)

    2016-12-13

    Dec 13, 2016 ... C virus had been demonstrated by Gottsch et al.[9] ... left eye (LE) involving 1½ h was managed with a scleral rotational autograft at the Rachel Eye Center, Abuja. The patient was a .... importation of the tissues can be time‑consuming. When .... and autologous serum eye drops in Mooren's ulcer. Nepal J ...

  3. Normobaric Oxygen Therapy for Scleral Ischemia or Melt

    Directory of Open Access Journals (Sweden)

    Farideh Sharifipour

    2012-01-01

    Full Text Available Purpose: To investigate the efficacy of normobaric oxygen (NBO therapy for treatment of scleral ischemia or melt. Methods: This prospective interventional case series includes 9 eyes of 8 patients with scleral ischemia or melt of diverse etiologies. Following the failure of conventional medical and/or surgical therapy to improve ischemia or upon clinical deterioration, NBO was initiated. All patients received 100% NBO at flow rate of 10 liters/minute by face mask for 1 hour, twice daily until complete vascularization of ischemic areas. Main outcome measures were improvement of scleral ischemia and healing of conjunctival epithelial defects. Results: NBO therapy led to epithelialization and vascularization of the ischemic sclera in all eyes; the repair process began 3-4 days after NBO had been initiated and was completed in 18.1±4.7 (range, 10-25 days. All patients remained stable over a 9-month follow-up period. Conclusion: NBO therapy seems effective for treatment of scleral ischemia or melt, and hence can be considered as a non-invasive alternative to surgical intervention in these conditions.

  4. Scleral fibroblast response to experimental glaucoma in mice

    Science.gov (United States)

    Tezel, Gülgün; Cone-Kimball, Elizabeth; Steinhart, Matthew R.; Jefferys, Joan; Pease, Mary E.; Quigley, Harry A.

    2016-01-01

    Purpose To study the detailed cellular and molecular changes in the mouse sclera subjected to experimental glaucoma. Methods Three strains of mice underwent experimental bead-injection glaucoma and were euthanized at 3 days and 1, 3, and 6 weeks. Scleral protein expression was analyzed with liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) using 16O/18O labeling for quantification in 1- and 6-week tissues. Sclera protein samples were also analyzed with immunoblotting with specific antibodies to selected proteins. The proportion of proliferating scleral fibroblasts was quantified with Ki67 and 4’,6-diamidino-2-phenylindole (DAPI) labeling, and selected proteins were studied with immunohistochemistry. Results Proteomic analysis showed increases in molecules involved in integrin-linked kinase signaling and actin cytoskeleton signaling pathways at 1 and 6 weeks after experimental glaucoma. The peripapillary scleral region had more fibroblasts than equatorial sclera (p=0.001, n=217, multivariable regression models). There was a sixfold increase in proliferating fibroblasts in the experimental glaucoma sclera at 1 week and a threefold rise at 3 and 6 weeks (p=0.0005, univariate regression). Immunoblots confirmed increases for myosin, spectrin, and actinin at 1 week after glaucoma. Thrombospondin-1 (TSP-1), HINT1, vimentin, actinin, and α-smooth muscle actin were increased according to immunohistochemistry. Conclusions Scleral fibroblasts in experimental mouse glaucoma show increases in actin cytoskeleton and integrin-related signaling, increases in cell division, and features compatible with myofibroblast transition. PMID:26900327

  5. SCLERAL AND CHOROIDAL THICKNESS IN SECONDARY HIGH AXIAL MYOPIA.

    Science.gov (United States)

    Shen, Ling; You, Qi Sheng; Xu, Xiaolin; Gao, Fei; Zhang, Zhibao; Li, Bin; Jonas, Jost B

    2016-08-01

    To assess differences in scleral and choroidal thickness between eyes with secondary high axial myopia caused by congenital glaucoma, eyes with primary high axial myopia, and nonhighly myopic eyes. The study consisted of 301 Chinese individuals with a mean age of 23.9 ± 22.6 years and mean axial length of 24.8 ± 4.2 mm. It included the "secondary highly myopic group" (SHMG) because of congenital glaucoma (n = 20 eyes; axial length >26.0 mm), the "primary highly myopic group" (PHMG) (n = 73; axial length >26.0 mm), and the remaining nonhighly myopic group (NHMG). The secondary highly myopic group versus the primary highly myopic group had significantly thinner sclera in the pars plana region (343 ± 71 μm versus 398 ± 83 μm; P = 0.006), whereas scleral thickness in other regions did not differ significantly between both highly myopic groups and was significantly thinner in both highly myopic groups than in the NHMG. Mean total scleral volume did not differ significantly (P > 0.20) between any group (SHMG: 659 ± 106 μm; PHMG: 667 ± 128 μm; NHMG: 626 ± 135 μm). Choroidal thickness was significantly thinner in both highly myopic groups than in the NHMG, with no significant differences between both highly myopic groups. Choroidal volume did not differ significantly (P > 0.40) between any of the groups (SHMG: 43 ± 12 μm; PHMG: 43 ± 13 μm; NHMG: 46 ± 17 μm). In secondary high axial myopia, the sclera gets thinner anterior and posterior to the equator; whereas in primary high axial myopia, scleral thinning is predominantly found posterior to the equator. Because volume of sclera and choroid did not differ between any group, scleral and choroidal thinning in myopia may be due to a rearrangement of tissue and not due to the new formation of tissue.

  6. Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery

    Directory of Open Access Journals (Sweden)

    Jea H. Yu

    2016-01-01

    Full Text Available Purpose. To report a new technique for anterior placement of tubes for glaucoma drainage devices to reduce the risk of tube erosions. Methods. Retrospective review of select cases of Ahmed Valve surgery combined with the novel method of a limbal-based scleral flap covered by a scleral patch graft to cover the tube at the entrance through the limbus. Intraoperative and postoperative illustrations are shown to highlight the method of tube placement. Results. In this retrospective case series, 3 patients are presented illustrating the technique. Two had neovascular glaucoma and one had primary open-angle glaucoma (POAG. On average, intraocular pressure was reduced from 39±14 mmHg to 15±2 mmHg and the number of glaucoma medications was reduced from 4±1 to 0. Preoperative and most recent visual acuities were hand-motion (HM and HM, 20/60 and 20/50, and 20/70 and 20/30, respectively. Conclusion. The combination of a limbal-based scleral flap with scleral patch graft to cover the tube with glaucoma drainage devices may be an effective means to reduce erosion and protect against endophthalmitis.

  7. Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery.

    Science.gov (United States)

    Yu, Jea H; Nguyen, Chuck; Gallemore, Esmeralda; Gallemore, Ron P

    2016-01-01

    Purpose . To report a new technique for anterior placement of tubes for glaucoma drainage devices to reduce the risk of tube erosions. Methods . Retrospective review of select cases of Ahmed Valve surgery combined with the novel method of a limbal-based scleral flap covered by a scleral patch graft to cover the tube at the entrance through the limbus. Intraoperative and postoperative illustrations are shown to highlight the method of tube placement. Results . In this retrospective case series, 3 patients are presented illustrating the technique. Two had neovascular glaucoma and one had primary open-angle glaucoma (POAG). On average, intraocular pressure was reduced from 39 ± 14 mmHg to 15 ± 2 mmHg and the number of glaucoma medications was reduced from 4 ± 1 to 0. Preoperative and most recent visual acuities were hand-motion (HM) and HM, 20/60 and 20/50, and 20/70 and 20/30, respectively. Conclusion . The combination of a limbal-based scleral flap with scleral patch graft to cover the tube with glaucoma drainage devices may be an effective means to reduce erosion and protect against endophthalmitis.

  8. Topical petrolatum gel alone versus topical silver sulfadiazine with standard gauze dressings for the treatment of superficial partial thickness burns in adults: a randomized controlled trial.

    Science.gov (United States)

    Genuino, Glenn Angelo S; Baluyut-Angeles, Kathrina Victoria; Espiritu, Andre Paolo T; Lapitan, Marie Carmela M; Buckley, Brian S

    2014-11-01

    Non-extensive superficial partial thickness burns constitute a major proportion of burns. Conventional treatment involves regular changing of absorptive dressings including the application of a topical antimicrobial, commonly silver sulfadiazine. A systematic review has found insufficient evidence to support or refute such antimicrobial prophylaxis. Another review compared silver sulfadiazine dressings with other occlusive and non-antimicrobial dressings and found insufficient evidence to guide practice. Other research has suggested that dressings with petrolatum gel are as effective as silver sulfadiazine. Single-center, randomized, controlled parallel group trial comparing conventional silver sulfadiazine dressings with treatment with petrolatum gel alone. Consenting adults 18-45 years old with superficial partial thickness burns≤10% total body surface area seen within 24h of the injury were randomized to daily dressing either with petrolatum gel without top dressings or conventional silver sulfadiazine treatment with gauze dressings. Primary outcomes were blinded assessment of time to complete re-epithelialization, wound infection or allergic contact dermatitis. Secondary outcomes included assessment of ease, time and pain of dressing changes. 26 patients were randomized to petrolatum and 24 to silver sulfadiazine dressings. Follow up data available for 19 in each group. Mean time to re-epithelialization was 6.2 days (SD 2.8) in the petrolatum group and 7.8 days (SD 2.1) in the silver sulfadiazine group (p=0.050). No wound infection or dermatitis was observed in either group. Scores for adherence to wound, ease of dressing removal and time required to change dressings were significantly better in the petrolatum treatment arm (ptreatment of minor superficial partial thickness burns in adults. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  9. Experimental transconjunctival diode laser retinal photocoagulation through silicone scleral exoplants.

    Science.gov (United States)

    Nanda, S K; Han, D P

    1995-07-01

    To study the feasibility of inducing a chorioretinal lesion under a previously placed scleral buckle by experimental transconjunctival diode laser photocoagulation. We performed transconjunctival diode laser photocoagulation in the peripheral retinas of seven pigmented rabbit eyes with a silicone exoplant (No. 42 band or No. 276 tire) and seven eyes without an exoplant. Each eye received burns with an intensity of grades 1 to 3 in different quadrants at varying power levels, with a 0.5-second duration and 650-micron spot size. Eyes were enucleated for histopathologic studies 1 day and 1 week after treatment. Although the irradiance emitted through the No. 42 band and the No. 276 tire was attenuated by 17% and 23%, respectively, the range of threshold powers needed to produce grades 1 to 3 burns was similar between eyes with and without a silicone exoplant. At 1 day, full-thickness coagulative necrosis was observed in all lesions, except that the ganglion cell layer and inner nuclear layer were preserved in two of four grade 1 burns and the ganglion cell layer was intact in one of six grade 2 burns. Inner scleral changes were noted acutely in three of five grade 3 lesions. At 1 week, burns of all intensity grades showed a full-thickness atrophic chorioretinal lesion with inner scleral changes. Experimental transconjunctival diode laser photocoagulation through hard silicone elements reproducibly created a chorioretinal lesion with histopathologic findings similar to those of lesions obtained without these elements. Although retinal photocoagulative effects were prominent, inner scleral abnormalities were also observed histologically.

  10. Scleral buckling for retinal detachment in patients with retinoblastoma

    International Nuclear Information System (INIS)

    Buzney, S.M.; Pruett, R.C.; Regan, C.D.; Walton, D.S.; Smith, T.R.

    1984-01-01

    Three children (two girls and one boy) with bilateral retinoblastoma each developed a presumed rhegmatogenous retinal detachment in one eye. All three eyes had previously received radiation and cryotherapy. In each case the retinal detachment responded promptly to conventional surgical methods via scleral buckling in the area of treated retinoblastoma and presumed retinal break. All three eyes have retained useful vision for follow-up periods of 3.5 to 12 years

  11. Scleral buckling for retinal detachment in patients with retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Buzney, S.M.; Pruett, R.C.; Regan, C.D.; Walton, D.S.; Smith, T.R.

    1984-10-15

    Three children (two girls and one boy) with bilateral retinoblastoma each developed a presumed rhegmatogenous retinal detachment in one eye. All three eyes had previously received radiation and cryotherapy. In each case the retinal detachment responded promptly to conventional surgical methods via scleral buckling in the area of treated retinoblastoma and presumed retinal break. All three eyes have retained useful vision for follow-up periods of 3.5 to 12 years.

  12. Bilateral spontaneous subluxation of scleral-fixated intraocular lenses.

    Science.gov (United States)

    Assia, Ehud I; Nemet, Arie; Sachs, Dani

    2002-12-01

    Two young men with primary ectopic lenses had intracapsular cataract extraction and scleral fixation of posterior chamber intraocular lenses (PC IOLs) using 10-0 polypropylene sutures tied to the IOL eyelets. Three to 9 years after implantation, spontaneous IOL vertical subluxation occurred in all 4 eyes (5 IOL loops), probably because of suture breakage. Late subluxation of a sutured IOL may occur several years after implantation. Double fixation and thicker sutures should be considered, especially in young patients.

  13. Clinical effectiveness, quality of life and cost-effectiveness of Flaminal® versus Flamazine® in the treatment of partial thickness burns: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Rashaan, Zjir M; Krijnen, Pieta; van den Akker-van Marle, M Elske; van Baar, Margriet E; Vloemans, Adrianus F P; Dokter, Jan; Tempelman, Fenike R H; van der Vlies, Cees H; Breederveld, Roelf S

    2016-03-05

    Partial thickness burns are painful, difficult to manage and can have a negative effect on quality of life through scarring, permanent disfigurement and loss of function. The aim of burn treatment in partial thickness burns is to save lives, stimulate wound healing by creating an optimumly moist wound environment, to have debriding and analgesic effects, protect the wound from infection and be convenient for the patient and caregivers. However, there is no consensus on the optimal treatment of partial thickness wounds. Flaminal® and Flamazine® are two standard treatment options that provide the above mentioned properties in burn treatment. Nevertheless, no randomized controlled study has yet compared these two common treatment modalities in partial thickness burns. Thus, the aim of this study is to evaluate the clinical effectiveness, quality of life and cost-effectiveness of Flaminal® versus Flamazine® in the treatment of partial thickness burns. In this two-arm open multi-center randomized controlled trial, 90 patients will be randomized between Flaminal® and Flamazine® and followed for 12 months. The study population will consist of competent or temporarily non-competent (because of sedation and/or intubation) patients, 18 years of age or older, with acute partial thickness burns and a total body surface area (TBSA) of less than 30 %. The main study outcome is time to complete re-epithelialization (greater than 95 %). Secondary outcome measures include need for grafting, wound colonization/infection, number of dressing changes, pain and anxiety, scar formation, health-related quality of life (HRQoL), and costs. This study will contribute to the optimal treatment of patients with partial thickness burn wounds and will provide evidence on the (cost-)effectiveness and quality of life of Flaminal® versus Flamazine® in the treatment of partial thickness burns. Netherlands Trial Register NTR4486 , registered on 2 April 2014.

  14. Single-suture scleral fixation of subluxated foldable intraocular lenses.

    Science.gov (United States)

    Yarangumeli, Alper; Alp, Mehmet Numan; Kural, Gulcan

    2012-01-01

    To evaluate the results of single-suture scleral fixation of subluxated foldable intraocular lenses (IOL) in eyes with sufficient residual capsular support. The results of IOL repositioning by single-suture scleral fixation in 6 eyes of 6 patients with IOL subluxation were included. All subluxated IOLs were single-piece hydrophilic acrylic. Subluxation resulted from posterior capsule tears in 3 eyes, zonular dialyses in 2 eyes, and zonular dialysis with a capsulorhexis tear in 1 eye. A similar technique was used in all eyes in which one haptic was externalized through a superior clear corneal incision and tied with a Pair-PAK 10-0 polypropylene suture, and was finally retracted and fixated behind the iris close to the ciliary sulcus at the 12:00 meridian. All patients were followed up for at least 6 months. Best-corrected visual acuities ranged between finger counting and 20/70 (mean logMAR 1.02±0.64) preoperatively, and between 20/100 and 20/20 (mean logMAR 0.22±0.26) at the final postoperative visit. All IOLs remained centered and no significant postoperative complications were encountered except for an IOL tilt which resulted in a considerable oblique astigmatism in one eye. Subluxated foldable IOLs may safely be repositioned and secured with a single scleral fixation suture in selected cases with adequate amount of capsular remnants.

  15. The Management of Refractory Dry Eye With Semi-Scleral Contact Lens.

    Science.gov (United States)

    Yuksel, Erdem; Bilgihan, Kamil; Novruzlu, Şahin; Yuksel, Nilay; Koksal, Murat

    2016-05-19

    We presented a case of refractory dry eye management with semi-scleral contact lens. Dry eye was associated with facial nerve (cranial nerve VII) palsy as a result of cerebellopontine angle tumor surgery. She was treated with several topical treatments and punctal plug. Despite the treatments, her symptoms still persisted. Her ophthalmic examination revealed scleral exposure because of lagophthalmos, conjunctival hyperemia, corneal debris, scar, and diffuse punctate epitheliopathy on her right eye. Lissamine green staining showed diffuse conjunctival and corneal staining. Therapeutic semi-scleral lenses were fitted. The corneal findings were resolved and the quality of patient life was improved with the aid of semi-scleral lens after 3 months.

  16. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... amendments), as ``preamendments devices.'' FDA classifies these devices after the Agency takes the following.... FDA-2012-N-1238] Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug AGENCY: Food... scleral plugs in order to provide a reasonable assurance of safety and effectiveness of the device. The...

  17. Investigation of scleral buckling by CO2 laser

    International Nuclear Information System (INIS)

    Maswadi, S.

    2001-05-01

    This thesis investigates the effect of using the infrared wavelength CO 2 laser (10.6μm) as a localised heat source for inducing scleral buckling on eyes. Retinal detachment disease is a major cause of blindness and the scleral buckling is an important technique used in treatment. A radio-frequency excited 10.6λm laser source is used to heat collagen in the sclera above its shrinkage temperature so as to produce a localised indentation and deformation in the human eye (in vitro). Basic measurements of the onset shrinkage temperatures of porcine and human sclera are taken. Optical properties of sclera tissue at 10.6μm are also determined to provide information about the interaction of the CO 2 laser with the sclera. It is found that CO 2 laser radiation is highly absorbed by the scleral water. Optical diffraction technique is investigated to quantify in-plane deformation in the sclera tissue as result of heating by producing grating on porcine and human sclera using the ArF laser (193nm). Photothermal deflection technique is also used to investigate scleral ablation by using the TEA and Ultrapulse CO 2 laser. This technique provides a useful guide to the regime where ablation rather than heat shrinkage of collagen in the sclera will dominate using the Ultrapulse CO 2 laser. A quantitative assessment of buckling using the technique of projection moire interferometry is described which allows a non-contact measurement to be made of the out-of-plane displacement by laser radiation. In-plane surface strain (shrinkage) has also been demonstrated using in-situ optical microscopy of the laser treated eye. The moire method is suitable to obtain information on buckling in real time and to obtain a three-dimensional view of the eye surface as laser treatment proceeds. A theoretical heat flow model is described for predicting the temperature profile produced in the sclera using the Ultrapulse CO 2 laser. For appropriate exposure parameters the CO 2 laser is found to be an

  18. Investigation of scleral buckling by CO{sub 2} laser

    Energy Technology Data Exchange (ETDEWEB)

    Maswadi, S

    2001-05-01

    This thesis investigates the effect of using the infrared wavelength CO{sub 2} laser (10.6{mu}m) as a localised heat source for inducing scleral buckling on eyes. Retinal detachment disease is a major cause of blindness and the scleral buckling is an important technique used in treatment. A radio-frequency excited 10.6{lambda}m laser source is used to heat collagen in the sclera above its shrinkage temperature so as to produce a localised indentation and deformation in the human eye (in vitro). Basic measurements of the onset shrinkage temperatures of porcine and human sclera are taken. Optical properties of sclera tissue at 10.6{mu}m are also determined to provide information about the interaction of the CO{sub 2} laser with the sclera. It is found that CO{sub 2} laser radiation is highly absorbed by the scleral water. Optical diffraction technique is investigated to quantify in-plane deformation in the sclera tissue as result of heating by producing grating on porcine and human sclera using the ArF laser (193nm). Photothermal deflection technique is also used to investigate scleral ablation by using the TEA and Ultrapulse CO{sub 2} laser. This technique provides a useful guide to the regime where ablation rather than heat shrinkage of collagen in the sclera will dominate using the Ultrapulse CO{sub 2} laser. A quantitative assessment of buckling using the technique of projection moire interferometry is described which allows a non-contact measurement to be made of the out-of-plane displacement by laser radiation. In-plane surface strain (shrinkage) has also been demonstrated using in-situ optical microscopy of the laser treated eye. The moire method is suitable to obtain information on buckling in real time and to obtain a three-dimensional view of the eye surface as laser treatment proceeds. A theoretical heat flow model is described for predicting the temperature profile produced in the sclera using the Ultrapulse CO{sub 2} laser. For appropriate exposure

  19. A new surgical technique of intra-scleral tube fixation in Ahmed Glaucoma Valve implantation: ‘Scleral Sleeve Method’

    Directory of Open Access Journals (Sweden)

    Charudutt Kalamkar

    2017-10-01

    Full Text Available Purpose: To present a new surgical technique ‘Scleral Sleeve Method’ which would reduce the risk of Ahmed Glaucoma Valve (AGV tube related complications in patients undergoing AGV FP7 (New World Medical Inc., Rancho Cucamonga, CA for refractory glaucoma. Design: Prospective, Non-Randomized, hospital based interventional case series. Subjects: A total of 16 eyes of adult patients (10 males and 6 females with refractory glaucoma. Methods: Instead of using sutures to fix the AGV tube to sclera, we devised a novel method of intra-scleral tube fixation by creating a scleral tunnel fashioned in form of sleeve. Main outcome measure: Post-operative tube related complications. Result: There were no tube related complications such as exposure, extrusion or retraction in any of the cases. Conclusion: Use of scleral sleeve method for tube fixation, along with graft to cover the tube, will provide additional safety measure and reduce the risks of tube related complications. Keywords: Ahmed Glaucoma Valve, Scleral Sleeve Method, Intra-scleral tube fixation

  20. Clinical observation of modified hydroxyapatite implant in scleral shell

    Directory of Open Access Journals (Sweden)

    Qing-Wei Du

    2014-10-01

    Full Text Available AIM: To evaluate the clinical effects of modified hydroxyapatite implant in scleral shell.METHODS:Thirty-four cases were performed eye evisceration, autogenous sclera shell anterior and posterior petaloid shape with posterior sclera fenestration, hydroxyapatite artificial eyeballs were implanted at stage I, and conjunctival wound, orbital activity and other complications were observed after surgery.RESULTS: The follow-up was 6~12mo. There was no patients with implant exposure, sclera dissolution, conjunctival wound dehiscence, conjunctival sac constriction noted. All the patients got good activity of artificial globe, and the active range of side motion of the HA was 10°~15°.The artificial eyes looked symmetrical, and the eyes socket were full.CONCLUSION: The modified hydroxyapatite implant in scleral shell can maintain the normal anatomy of the orbital tissue, and also can get full eyes socket and good activity, It was an easy and simple surgery which could obtain satisfactory clinical effect and less complications.

  1. Effect of scleral buckle removal on strabismus surgery outcomes after retinal detachment repair

    Science.gov (United States)

    Chang, Jee Ho; Hutchinson, Amy; Zhang, Monica; Lambert, Scott R.

    2015-01-01

    Background/Aims To investigate the effect of scleral buckle removal on the outcomes of strabismus surgery in patients with a prior history of retinal detachment surgery. Methods We reviewed the medical records of 18 patients who underwent strabismus surgery following a scleral buckling procedure at one institution. We investigated the effect of multiple variables on outcome, including: gender, age, surgeon, number of strabismus surgeries, adjustable suture use, previous pars plana vitrectomy, preoperative best-corrected visual acuity and time of surgery. Outcomes were considered successful if there was ≤ 10 prism diopter (PD) residual horizontal and/or ≤ 4 PD residual vertical deviation. Outcomes were analyzed statistically using Fisher's exact test and Mann-Whitney test. Results Strabismus surgery coupled with scleral buckle removal was associated with a higher rate of success (success with buckle removal, 62.5%; success without buckle removal, 10.0%; p=0.04). There were no significant difference in preoperative findings between the scleral buckle removal and non- removal groups. No retinal redetachments occurred after scleral buckle removal. Conclusion In our series, scleral buckle removal was associated with improved surgical outcome in patients with strabismus following a scleral buckling procedure. PMID:24299332

  2. Aquacel(®) Ag dressing versus Acticoat™ dressing in partial thickness burns: a prospective, randomized, controlled study in 100 patients. Part 1: burn wound healing.

    Science.gov (United States)

    Verbelen, Jozef; Hoeksema, Henk; Heyneman, Alexander; Pirayesh, Ali; Monstrey, Stan

    2014-05-01

    Studies comparing contemporary silver dressings in burns are scarce. In a prospective, randomized, controlled study, counting 50 patients/research group, we compared two frequently used silver dressings, Acticoat™ and Aquacel(®) Ag, in the management of partial thickness burns with a predicted healing time between 7 and 21 days as assessed by laser Doppler imaging between 48 and 72h after burn. Variables investigated were related to baseline research group characteristics, wound healing, bacteriology, economics, nurse, and patient experience. Both research groups were comparably composed taking into account gender, age and burn characteristics. Similar results were obtained as to healing time and bacterial control with both silver dressings. A statistically significant difference in favor of the Aquacel(®) Ag dressing was found for average ease of use (p<0.001), average ease of application (p=0.001), patient pain (p<0.001), patient comfort with the dressing (p=0.017), silver staining (p<0.001), and cost effectiveness (p<0.001). Both silver dressings resulted in comparable healing times and bacterial control but the Aquacel(®) Ag dressing significantly increased comfort for patients as well as nurses and was significantly more cost-effective than the Acticoat™ dressing for the given indication. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  3. Clinical observation of the glaucoma trabeculectomy with tunnel knife making the double-deck scleral flap

    Directory of Open Access Journals (Sweden)

    Min Fu

    2015-07-01

    Full Text Available AIM: To study the trabeculectomy clinical effect of use tunnel knife to make double-deck scleral flap and to cut off the layer scleral flap of glaucoma.METHODS:Using the random grouping method to divide 46 cases(60 eyesof glaucoma into the treatment group of 24 cases(32 eyesand control group of 22 cases(28 eyes. The treatment group, tunnel knife was used to make double-deck sclera flap and superficial scleral flap about the size of 5mm×5.5mm,1/3 scleral thickness, under the sclera flap made another one about the size of 3.5mm×4mm, 1/3 scleral thickness, resected the middle layer of the sclera flap, removed 2mm×2mm trabecular tissue, underwent routine peripheral iridectomy, could adjust suture the superficial scleral flap, sutured Ball fascia and bulbar conjunctiva. In control group, routine glaucoma trabeculectomy was undergone.RESULTS:Patients were followed up for 1a, the vision in treatment group was obviously better than that in the control group, with a statistically significant difference(PP>0.05. But after 6 and 12mo, the intraocular pressure of the treatment group were significantly lower than that of the control group, with statistically significant difference(PPCONCLUSION:The trabeculectomy have a good effect to lower the intraocular pressure by use tunnel knife to make double-deck scleral flap and to cut off the layer scleral flap. The scleral flap have uniform thickness, smooth surface, and the function of the filtering bleb maintained for a long time, less postoperative complications, suitable for various types of glaucoma, so it is worthy of clinical promotion.

  4. Application analysis on different suture of scleral flap in trabeculectomy

    Directory of Open Access Journals (Sweden)

    Ning Liu

    2014-05-01

    Full Text Available AIM: To research the application of scleral flap suture in trabeculectomy. METHODS: Totally 114 primary angle-closure glaucoma patients, aged from 36-72 years old, were selected as the objects, and randomly divided into research group and control group. The two groups received different administration methods. Traditional sewing method of sclera flap was used in research group and improved sewing method of sclera flap was used in control group. RESULTS: There was statistical differences between postoperative intraocular pressure of the patients in the observation group and the control group after 1d; 2wk; 1, 3mo(PPP>0.05.CONCLUSION: It is safe and effective that the improved sewing method of sclera flap for trabeculectomy of acute angle-closure glaucoma, and it is a better method to avoid the occurrence of shallow anterior chamber than the traditional sewing method in the early stage after operation.

  5. Oxygen Tension Beneath Scleral Lenses of Different Clearances.

    Science.gov (United States)

    Giasson, Claude J; Morency, Jeanne; Melillo, Marc; Michaud, Langis

    2017-04-01

    To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400). During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA. The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.

  6. [Effects of seawater immersion on the inflammatory response and oxygen free radical injury of rats with superficial partial-thickness scald at early stage].

    Science.gov (United States)

    Yang, Y X; Wang, J H; Liu, L; Zou, Q; Zhang, Y; Bai, Z

    2017-06-20

    Objective: To study the effects of seawater immersion on the inflammatory response and oxygen free radical injury of rats with superficial-thickness scald at early stage. Methods: Seventy Wistar rats were divided into healthy control group (HC, n =7), pure scald group (PS, n =21), scald+ fresh water immersion group (SF, n =21), and scald+ seawater immersion group (SS, n =21) according to the random number table. Rats in group HC did not receive any treatment, while 5% total body surface area superficial partial-thickness scald was made on the back of rats in the latter three groups. Rats in group PS lived freely immediately post burn, while wounds on the back of rats in groups SF and SS were immersed into fresh water and seawater, respectively. Serum and full-thickness skin tissue in the center of wounds on the back of 7 rats in groups PS, SF, and SS at post immersion (injury) hour (PIH) 2, 4, and 6 were collected, respectively, while serum and full-thickness skin tissue at the same position of the 7 rats in group HC were collected at PIH 6 of rats in other groups. Morphology of skin tissue was observed with HE staining; tumor necrosis factor-alpha (TNF-α) content in serum and skin tissue was determined by enzyme-linked immunosorbent assay; superoxide dismutase (SOD) content in serum and skin tissue was determined by hydroxylamine method; malondialdehyde content in serum and skin tissue was determined by thiobarbituric acid method. Data were processed with analysis of variance of factorial design, one-way analysis of variance, Welch test, LSD test, and Tamhane test. Results: (1) Epidermal cells of skin tissue of rats in group HC arranged in order and continuously, and the dermis tissue and accessory structures were clear and complete. The skin layer and epidermis of wounds of rats in group PS had no significant change, but the edema of epidermis and dermis and infiltration of inflammatory cells enhanced over time at PIH 2, 4, and 6. The horny layer of epidermis of

  7. Comparative effectiveness of different wound dressings for patients with partial-thickness burns: study protocol of a systematic review and a Bayesian framework network meta-analysis.

    Science.gov (United States)

    Jiang, Qiong; Chen, Zhao-Hong; Wang, Shun-Bin; Chen, Xiao-Dong

    2017-03-22

    Selecting a suitable wound dressing for patients with partial-thickness burns (PTBs) is important in wound care. However, the comparative effectiveness of different dressings has not been studied. We report the protocol of a network meta-analysis designed to combine direct and indirect evidence of wound dressings in the management of PTB. We will search for randomised controlled trials (RCTs) evaluating the wound-healing effect of a wound dressing in the management of PTB. Searches will be conducted in MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, the Cochrane Wounds Group Specialised Register and CINAHL. A comprehensive search strategy is developed to retrieve articles reporting potentially eligible RCTs. Besides, we will contact the experts in the field and review the conference proceedings to locate non-published studies. The reference lists of articles will be reviewed for any candidate studies. Two independent reviewers will screen titles and abstracts of the candidate articles. All eligible RCTs will be obtained in full text to perform a review. Disagreement on eligibility of an RCT will be solved by group discussion. The information of participants, interventions, comparisons and outcomes from included RCTs will be recorded and summarised. The primary outcome is time to complete wound healing. Secondary outcomes include the proportion of burns completely healed at the end of treatment, change in wound surface area at the end of treatment, incidence of adverse events, etc. The result of this review will provide evidence for the comparative effectiveness of different wound dressings in the management of PTB. It will also facilitate decision-making in choosing a suitable wound dressing. We will disseminate the review through a peer-review journal and conference abstracts or posters. PROSPERO CRD42016041574; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please

  8. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    International Nuclear Information System (INIS)

    Schreinemachers, Saskia A.; Hulst, Victor P.M. van der; Woude, Henk-Jan van der; Willems, W.J.; Bipat, Shandra

    2009-01-01

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  9. Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

    Energy Technology Data Exchange (ETDEWEB)

    Schreinemachers, Saskia A. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Amsterdam (Netherlands); Hulst, Victor P.M. van der; Woude, Henk-Jan van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Willems, W.J. [Onze Lieve Vrouwe Gasthuis, Orthopaedic Surgery, Amsterdam (Netherlands); Bipat, Shandra [University of Amsterdam (NL). Department of Radiology, Academic Medical Center (Netherlands)

    2009-10-15

    The purpose of this study was to retrospectively evaluate sensitivity and specificity of a single magnetic resonance (MR) arthrography series in abduction external rotation (ABER) position compared with conventional MR arthrography for detection of supraspinatus tendon tears, with arthroscopy as gold standard, and to assess interobserver variability. Institutional review board approval was obtained; informed consent was waived. MR arthrograms of 250 patients (170 men and 80 women; mean age, 36 years) were retrospectively and independently evaluated by three observers. Oblique coronal T1-weighted fat-suppressed images, proton density, and T2-weighted images and axial T1-weighted images and oblique sagittal T1-weighted fat-suppressed images were analyzed to detect supraspinatus tendon tears. Separately, a single T1-weighted fat-suppressed oblique axial series in ABER position was evaluated. Both protocols were scored randomly without knowledge of patients' clinical history and arthroscopy results. Tears were subclassified, based on articular surface integrity and extension (Lee classification). Interobserver agreement was assessed by kappa statistics for all patients. Ninety-two of 250 patients underwent arthroscopy; sensitivity and specificity of ABER and conventional MR arthrography were calculated and compared using paired McNemar test. Weighted kappa values of ABER and conventional MR arthrography were 0.48-0.65 and 0.60-0.67, respectively. According to arthroscopy, 69 of 92 patients had an intact cuff, and 23 patients had a cuff tear (16 partial thickness and seven full thickness). There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (48-61% and 52-70%, respectively) and specificity (80-94% and 91-95%). Sensitivity and specificity of a single T1-weighted series in ABER position and conventional MR arthrography are comparable for assessment of rotator cuff tears. (orig.)

  10. Preservation of bursal-sided tendon in partial-thickness articular-sided rotator cuff tears: a novel arthroscopic transtendon anatomic repair technique.

    Science.gov (United States)

    Shin, Sang-Jin; Jeong, Jae-Hoon; Jeon, Yoon Sang; Kim, Rag Gyu

    2016-12-01

    The purpose of this study was to introduce a novel arthroscopic transtendon anatomic repair technique that spares the intact bursal-sided tendon in articular-sided partial-thickness rotator cuff tears (PTRCT) and to present shoulder functional outcomes in patients with symptomatic articular-sided PCRCT that involves more than 50 % of its thickness after arthroscopic repair using a novel technique. Eighteen patients with symptomatic articular-sided PCRCT involving more than 50 % of the tendon's thickness underwent arthroscopic repair using a devised technique. The devised technique restores only the torn articular portion of the rotator cuff at the anatomical footprint using a suture anchor, and preserves the integrity of the corresponding bursal-sided tendon by tying knots at the most lateral bursal side on the subacromial space. Clinical and functional outcome using ASES and Constant scores were evaluated. The structural integrity of the rotator cuff was evaluated by MRI at 6 months postoperatively. Pain relief and shoulder functional outcomes were encouraging during the recovery phase after operation. ASES (preoperative 54.0 ± 10.3 to postoperative 92.6 ± 8.0), Constant score (61.2 ± 8.5-88.0 ± 5.3), VAS for pain (4.9 ± 2.6-0.6 ± 0.7) improved significantly after arthroscopic transtendon anatomic repair (p rotator cuff retears on 6-month MRI. No complications related to surgical procedures had occurred. The devised technique of arthroscopic transtendon repair provided satisfactory functional outcomes without postoperative discomforts. This technique minimizes over-tightening of the articular layer and reduces tension mismatches between the articular and bursal layers, which are considered as important factors for improvement of postoperative shoulder motion.

  11. Preparation and Evaluation of Biodegradable Scleral Plug Containing Curcumin in Rabbit Eye.

    Science.gov (United States)

    Zhang, Jun; Sun, Haiyan; Zhou, Nalei; Zhang, Bin; Ma, Jingxue

    2017-12-01

    To test whether biodegradable curcumin-loaded scleral plug is a promising choice for treating posterior ocular diseases, the study investigated the in vitro release profile of the scleral plug and its safety in vivo. Scleral plugs containing 0.5 mg, 1.0 mg and 1.5 mg curcumin were synthesized by a compression-sintering method. These scleral plugs were placed in tubes containing balanced salt solution (BSS) buffer, which was replaced by fresh buffer daily. The curcumin concentration in the removed aliquot was tested daily for 14 days using high-performance liquid chromatography (HPLC). In the study, 44 rabbits were randomly divided into four groups: control, 0.5 mg, 1.0 mg and 1.5 mg curcumin groups. The scleral plug was trans-scleral fixed in the right eye of the rabbits in the three curcumin-treated groups. The control rabbits only received sclerotomy. The treated rabbit eyes were examined by a slit-lamp biomicroscope, an indirect ophthalmoscope and electroretinogram (ERG), and subjected to histological analysis. The concentration of the 1.5 mg curcumin-loaded scleral plug was higher than 15 μg/ml for consecutive 14 days in vitro. The in vivo experiments revealed intraocular pressure, a-wave and b-wave amplitudes of ERG, and conjunctival reaction degree were not significantly different between the four groups. Retinal structure was normal in the curcumin-treated groups. The sclerotomy wound healed after the plug was completely degraded. Anterior chamber reaction or complications were not observed. The study suggests that curcumin-loaded scleral plug could sustain high concentration of curcumin in vitro and is safe in vivo. It might be a promising alternative choice for the treatment of posterior ocular diseases.

  12. Accelerated re-epithelialization of partial-thickness skin wounds by a topical betulin gel: Results of a randomized phase III clinical trials program.

    Science.gov (United States)

    Barret, Juan P; Podmelle, Fred; Lipový, Břetislav; Rennekampff, Hans-Oliver; Schumann, Hauke; Schwieger-Briel, Agnes; Zahn, Tobias R; Metelmann, Hans-Robert

    2017-09-01

    The clinical significance of timely re-epithelialization is obvious in burn care, since delayed wound closure is enhancing the risk of wound site infection and extensive scarring. Topical treatments that accelerate wound healing are urgently needed to reduce these sequelae. Evidence from preliminary studies suggests that betulin can accelerate the healing of different types of wounds, including second degree burns and split-thickness skin graft wounds. The goal of this combined study program consisting of two randomized phase III clinical trials in parallel is to evaluate whether a topical betulin gel (TBG) is accelerating re-epithelialization of split-thickness skin graft (STSG) donor site wounds compared to standard of care. Two parallel blindly evaluated, randomised, controlled, multicentre phase III clinical trials were performed in adults undergoing STSG surgery (EudraCT nos. 2012-003390-26 and 2012-000777-23). Donor site wounds were split into two equal halves and randomized 1:1 to standard of care (a non-adhesive moist wound dressing) or standard of care plus TBG consisting of 10% birch bark extract and 90% sunflower oil (Episalvan, Birken AG, Niefern-Oeschelbronn, Germany). The primary efficacy assessment was the intra-individual difference in time to wound closure assessed from digital photographs by three blinded experts. A total of 219 patients were included and treated in the two trials. Wounds closed faster with TBG than without it (15.3 vs. 16.5 days; mean intra-individual difference=-1.1 days [95% CI, -1.5 to -0.7]; p<0.0001). This agreed with unblinded direct clinical assessment (difference=-2.1 days [95% CI, -2.7 to -1.5]; p<0.0001). Adverse events possibly related to treatment were mild or moderate and mostly at the application site. TBG accelerates re-epithelialization of partial thickness wounds compared to the current standard of care, providing a well-tolerated contribution to burn care in practice. Copyright © 2017 The Authors. Published by

  13. Ocular Surface Temperature During Scleral Lens Wearing in Patients With Keratoconus.

    Science.gov (United States)

    Carracedo, Gonzalo; Wang, Zicheng; Serramito-Blanco, Maria; Martin-Gil, Alba; Carballo-Alvarez, Jesús; Pintor, Jesús

    2017-11-01

    To evaluate the ocular surface temperature using an infrared thermography camera before and after wearing scleral lens in patients with keratoconus and correlate these results with the tear production and stability. A pilot, experimental, short-term study has been performed. Twenty-six patients with keratoconus (36.95±8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (KC-ICRS group) and patients without ICRS (KC group). Schirmer test, tear breakup time (TBUT), and ocular surface temperature in the conjunctiva, limbus, and cornea were evaluated before and after wearing a scleral lens. The patients wore the scleral lenses from 6 to 9 hours with average of 7.59±0.73 hours. No significant changes in Schirmer test and TBUT were found for both groups. No temperature differences were found between the KC-ICRS and the KC groups for all zones evaluated. There was a slight, but statistically significant, increase in the inferior cornea, temporal limbus, and nasal conjunctival temperature for KC-ICRS group and temporal limbus temperature decreasing for the KC group after wearing scleral lens (Ptemperature was statistically higher than the central cornea for both groups before and after scleral lenses wearing (Pperipheral cornea was found. No statistically significant differences in the central corneal temperature were found between the groups after scleral lens wearing (P>0.05). Scleral contact lens seems not to modify the ocular surface temperature despite the presence of the tear film stagnation under the lens.

  14. Vitrectomy with and without scleral buckling for retinal detachment Vitrectomia com e sem "scleral buckling" para descolamento da retina

    Directory of Open Access Journals (Sweden)

    Rubens Camargo Siqueira

    2007-03-01

    Full Text Available PURPOSE: To compare the surgical results of vitrectomy with and without scleral buckling for rhegmatogenous retinal detachment (RD. METHODS: Fifty-one patients with rhegmatogenous retinal detachment with proliferative vitreoretinopathy (PVR at different stages were submitted to pars plana vitrectomy as the primary surgery, 23 patients (45.09% with scleral buckle (group I and 28 (54.90% without scleral buckle (group II. Visual acuity, anterior segment complications, intraocular pressure, strabismus and retina reattachment rate were evaluated in both groups. RESULTS: The anatomical success and postoperative complications were similar in both groups. Retinal reattachment was achieved in 20 of 23 eyes (87% of group I and in 24 of 28 eyes (85.7% of group II after the initial surgery (p=1.000. Elevated intraocular pressure was noted in 2 eyes (8.7% of group I and 1 eye (3.6% of group II (p=0.583. Corneal abnormalities were seen in 3 eyes (13% of group I and 2 eyes (7.19% of the group II (p=0.647. Visual acuity improved from a preoperative median of 20/200 to a median of 20/100 in group 1 and from 20/400 to 20/100 in group 2; the difference between the two groups was statistically significant (pOBJETIVOS: Comparar os resultados cirúrgicos da vitrectomia com e sem "buckle" escleral para descolamento da retina regmatogênico (DR. MÉTODOS: Cinqüenta e um pacientes com descolamento da retina regmatogênico com proliferação vitreorretiniana (PVR em diferentes estádios foram submetidos a vitrectomia pars plana como cirurgia primária; 23 pacientes (45,09% com buckle escleral (grupo 1 e 28 pacientes (54,90% sem "buckle" escleral (grupo 2. Acuidade visual, complicações do segmento anterior, pressão intra-ocular, estrabismo e razão do redescolamento da retina foram avaliados em ambos os grupos. RESULTADOS: O sucesso anatômico e complicações pós-operatórias foram semelhantes em ambos os grupos. A reaplicação da retina foi obtida em 20 dos 23

  15. Non-drainage scleral buckling with solid silicone elements

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2014-01-01

    Full Text Available Background: With the increasing number of cataract surgeries, incidence of posterior segment complications including rhegmatogenous retinal detachment (RRD is likely to rise. Scleral buckling (SB surgery is an effective and less expensive option. The primary advantage of non-drainage procedure is avoidance of possible complications associated with trans-choroidal drainage. The aim of present study is to describe the clinical profile of subjects undergoing non-drainage SB surgery with solid silicone elements for RRD and analyze their treatment outcomes. Materials and Methods: This was a retrospective, non-randomized, interventional study at a tertiary care center. Three hundred and six eyes of 298 patients undergoing non-drainage SB surgery with solid silicone elements from year 2000 to 2006 were included. Inclusion criteria were primary RRD, peripheral depressible retinal break, media clarity affording peripheral retinal view and proliferative vitreo-retinopathy (PVR up to grade C2. Uni- and multivariate analyses was done to analyze factors affecting anatomical and visual outcomes. Statistical analysis was performed using SPSS Version 10. Results: Mean follow-up was 303 ± 393.33 days. Primary anatomical success was obtained in 279 (91.2% eyes; primary functional success in 286 (93.5% eyes. PVR (grade B or C, intraocular pressure <10 mm Hg and the inability to find a retinal break were significantly associated with final anatomical failure. Baseline vision ≤3/60 was significantly associated with poor visual recovery. Conclusions: SB surgery is reasonably safe and highly efficacious. Solid silicone elements are effective in non-drainage SB surgery. However, case selection is important.

  16. [Subluxation of scleral-fixated PC IOL caused by polypropylene suture degradation--case report].

    Science.gov (United States)

    Kanigowska, Krystyna; Grałek, Mirosława; Czarnowska, Elzbieta; Zajaczkowska, Agnieszka

    2009-01-01

    The purpose of the study is to evaluate factors related to late-onset of lens subluxation in transscleral sutured posterior chamber IOL. We report a child, which required surgical treatment for dislocation of a scleral-sutured PC IOL. 11 years earlier the secondary lens implantation with scleral fixation was performed in 4 years old boy. The first surgical procedure included an anterior victrectomy and suturing a single- piece PMMA IOL under the scleral flaps with a 10-0 polipropylene suture. The second--included explantation of the dislocated lens. Optic and scanning electron microscopy was used to analyze the surface of the explanted remnants of the breakage suture. Microscopic findings indicate that the late suture breakage and subluxation of suture-fixated PC IOL was due to the degradation of polypropylene suture.

  17. Sutureless, Glueless, Scleral Fixation of Single-Piece and Toric Intraocular Lens: A Novel Technique

    Directory of Open Access Journals (Sweden)

    Aditya Kelkar

    2015-07-01

    Full Text Available Sutureless, glueless, scleral fixation of an intraocular lens is a known technique of fixing a lens in the scleral pockets. However, this technique is applied to single-piece and toric lenses instead of 3-piece lenses, allowing the advantage of the use of premium lenses in patients with poor capsular support. Favourable results without complications of pigment dispersion, iris transillumination defects, dysphotopsia, elevated intraocular pressure, intraocular hemorrhage and cystoid macular edema with a well-centered, stable intraocular lens have been observed in the 3-month postoperative period in both cases.

  18. An epibulbar chocolate cyst: a rare complication of silicone-based scleral buckle.

    Science.gov (United States)

    Venkatesh, Pradeep; Gogia, Varun; Gupta, Shikha; Nayak, Bhagabat

    2015-08-03

    A patient with a history of vitreoretinal surgery presented with nasal dystopia, diplopia and epibulbar bluish black mass simulating a chocolate cyst in the right eye. After a non-conclusive ocular examination, he underwent CT of the orbit along with volume rendition and three-dimensional reconstruction, which demonstrated intact globe with laterally displaced band-buckle assembly along with peri-scleral buckle element (SBE) soft tissue proliferation. Imaging-assisted exploration of the lesion was performed and retained scleral buckle element (SBE) was removed in toto; thus relieving the patient long-standing dystopia. 2015 BMJ Publishing Group Ltd.

  19. Sutureless intrascleral intraocular lens fixation with lamellar dissection of scleral tunnel

    Directory of Open Access Journals (Sweden)

    Kawaji T

    2016-01-01

    Full Text Available Takahiro Kawaji,1,2 Tomoki Sato,2 Hidenobu Tanihara11Department of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Chuo-ku, 2Sato Eye & Internal Medicine Clinic, Kumamoto, JapanPurpose: To report the results of sutureless scleral fixation of a posterior chamber intraocular lens (IOL by using our developed simple technique.Methods: We retrospectively reviewed the medical records of 48 eyes of 47 patients who underwent sutureless intrascleral IOL fixation by using our modified technique. A 25-gauge microvitreoretinal knife was used to perform sclerotomies and create limbus-parallel scleral tunnels with lamellar dissection in which the haptics were fixed.Results: The IOLs were fixed and centered well. The mean follow-up period was 26.7 months. Postoperative complications included smooth vitreous hemorrhage in four eyes (8.3%, cystoid macular edema in two eyes (4.2%, and iris capture of the IOL in two eyes (4.2%. No other complications, such as breakage of the IOL, spontaneous IOL dislocation, or retinal detachment, were detected during the follow-up period.Conclusion: The lamellar dissection of the limbus-parallel scleral tunnel can simplify the forceps-assisted introduction of the haptics into the scleral tunnel, and this technique seemed to be safe.Keywords: intraocular lenses, ophthalmologic surgical procedures, intrascleral fixation, sutureless fixation

  20. An investigation of CO2 laser scleral buckling using moiré interferometry.

    Science.gov (United States)

    Maswadi, Saher M; Dyer, Peter E; Verma, Dinesh; Jalabi, Wadah; Dave, Dinesh

    2002-01-01

    To demonstrate suitability of moiré interferometry to assess and quantify laser-induced shrinkage of scleral collagen for buckling procedures. Scleral buckling of human cadaver eyes was investigated using a Coherent Ultrapulse CO2 laser. Projection moiré interferometry was employed to determine the out-of plane displacement produced by laser exposure, and in-situ optical microscopy of reference markers on the eye was used to measure in-plane shrinkage. Measurements based on moiré interferometry allow a three dimensional view of shape changes in the eye surface as laser treatment proceeds. Out-of-plane displacement reaches up to 1.5 mm with a single laser spot exposure. In-plane shrinkage reached a maximum of around 30%, which is similar to that reported by Sasoh et al (Ophthalmic Surg Lasers. 1998;29:410) for a Tm:YAG laser. The moiré technique is found to be suitable for quantifying the effects of CO2 laser scleral shrinkage and buckling. This can be further developed to provide a standardized method for experimental investigations of other laser sources for scleral shrinkage.

  1. cAMP level modulates scleral collagen remodeling, a critical step in the development of myopia.

    Directory of Open Access Journals (Sweden)

    Yijin Tao

    Full Text Available The development of myopia is associated with decreased ocular scleral collagen synthesis in humans and animal models. Collagen synthesis is, in part, under the influence of cyclic adenosine monophosphate (cAMP. We investigated the associations between cAMP, myopia development in guinea pigs, and collagen synthesis by human scleral fibroblasts (HSFs. Form-deprived myopia (FDM was induced by unilateral masking of guinea pig eyes. Scleral cAMP levels increased selectively in the FDM eyes and returned to normal levels after unmasking and recovery. Unilateral subconjunctival treatment with the adenylyl cyclase (AC activator forskolin resulted in a myopic shift accompanied by reduced collagen mRNA levels, but it did not affect retinal electroretinograms. The AC inhibitor SQ22536 attenuated the progression of FDM. Moreover, forskolin inhibited collagen mRNA levels and collagen secretion by HSFs. The inhibition was reversed by SQ22536. These results demonstrate a critical role of cAMP in control of myopia development. Selective regulation of cAMP to control scleral collagen synthesis may be a novel therapeutic strategy for preventing and treating myopia.

  2. Scleral buckling procedure with chandelier illumination for pediatric rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Yokoyama T

    2015-01-01

    Full Text Available Toshiyuki Yokoyama, Koki Kanbayashi, Tamaki YamaguchiDepartment of Ophthalmology, Juntendo University Nerima Hospital, Tokyo, JapanPurpose: To assess the treatment of pediatric patients with rhegmatogenous retinal detachment (RRD by scleral buckling with chandelier illumination.Methods: Three eyes were treated in three patients, healthy boys aged 7 years, 12 years, and 11 years, with RRD, macular involvement, and small retinal holes, of which two were preoperatively undetectable. Conventional scleral buckling with cryoretinopexy was performed under the contact lens for vitreous surgery or noncontact wide-angle viewing system using 27-gauge twin chandelier illumination.Results: The only known predisposing factor for retinal detachment was myopia stronger than 3 D with lattice retinal degeneration in two of the three patients. Retinal reattachment was achieved in all cases without intra- or postoperative complications. However, visual recovery was limited in one of the three patients.Conclusion: Scleral buckling with chandelier illumination is effective for pediatric RRD, especially if the retinal hole is difficult to detect preoperatively. However, visual recovery was sometimes limited because of macular involvement due to late diagnosis, which is one of the characteristic features of pediatric RRD.Keywords: pediatric rhegmatogenous retinal detachment, chandelier illumination, scleral buckling

  3. Scleral suspension pars-plana lensectomy for ectopia lentis followed by suture fixation of intraocular lens

    Directory of Open Access Journals (Sweden)

    Mitra Sandip

    2001-01-01

    Full Text Available Purpose: To describe a simple technique of scleral suspension-pars plana lensectomy (SS-PPL in acquired and congenital ectopia lentis and scleral fixation of intraocular lens (IOL. Materials and Methods: Twenty eyes of 16 patients (12 unilateral and 4 bilateral cases of "essential familial lens subluxation" aged 10-40 years (mean 25 years underwent SS-PPL with implantation of scleral fixated IOL. Indications for surgery were best-corrected visual acuity <6/18, bisection of pupil by the lens, and lens-induced glaucoma. Prerequisites for SS-PPL were, visibility of part of the lens in the pupillary area and soft lens. Results: Postoperative visual acuity ranged from 6/6 - 6/36. Lens tilt in 3 cases(15% and small decentration in 2 cases(10% were seen; however these did not seriously compromise the visual result. Scant vitreous bleeding on the first postoperative day was seen in 3 cases (15%. Conclusion: The advantages of the scleral suspension of subluxated lens prior to lensectomy include stabilization; it allows proper viewing of the lens, avoids injury to the iris and cliary body during lensectomy and reduces the possibility of dislocation of the lens.

  4. Fitting an MSD (mini scleral design) rigid contact lens in advanced keratoconus with INTACS.

    Science.gov (United States)

    Dalton, Kristine; Sorbara, Luigina

    2011-12-01

    Keratoconus is a bilateral degenerative disease characterized by a non-inflammatory, progressive central corneal ectasia (typically asymmetric) and decreased vision. In its early stages it may be managed with spectacles and soft contact lenses but more commonly it is managed with rigid contact lenses. In advanced stages, when contact lenses can no longer be fit, have become intolerable, or corneal damage is severe, a penetrating keratoplasty is commonly performed. Alternative surgical techniques, such as the use of intra-stromal corneal ring segments (INTACS) have been developed to try and improve the fit of rigid contact lenses in keratoconic patients and avoid penetrating keratoplasties. This case report follows through the fitting of rigid contact lenses in an advanced keratoconic cornea after an INTACS procedure and discusses clinical findings, treatment options, and the use of mini-scleral and scleral lens designs as they relate to the challenges encountered in managing such a patient. Mini-scleral and scleral lenses are relatively easy to fit, and can be of benefit to many patients, including advanced keratoconic patients, post-INTAC patients and post-penetrating keratoplasty patients. 2011 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Reconstruction of delayed scleral flap melting with bovine pericardium after trabeculectomy with mitomycin C

    Directory of Open Access Journals (Sweden)

    Coutinho, Inês

    2017-06-01

    Full Text Available Aim: To present a challenging case of hypotony after trabeculectomy and its treatment. Case description: A 22-year-old woman with juvenile glaucoma underwent a conventional trabeculectomy with mitomycin C on the right eye (OD. In the immediate postoperative period, we observed a hyperfiltration bleb with hypotony refractory to conservative measures leading to hypotony maculopathy.A surgical revision with scleral flap resuture and conjunctival graft was performed with a satisfactory result and resolution of hypotony maculopathy. After two years, the patient complained of low visual acuity (VA of the OD. During examination, we observed a fine and avascular bleb with Seidel and visualization of the underlying uveal tissue, an intraocular pressure (IOP of 5 mmHg, and chorioretinal folds. A new revision of the trabeculectomy was performed. During the procedure, it was not possible to identify the scleral flap, so the fistula was closed with a patch of collagenous membrane derived from bovine pericardium (Tutopatch graft. A good clinical evolution occurred. After 2 months, IOP was 15 mmHg without Seidel or changes in the fundus and VA was 20/20. After of follow-up, the IOP remains stable without further complaints. Conclusion: This case illustrates the difficulties faced in the management of a common complication of trabeculectomy and highlights some of the options available for its treatment. There are few reports of scleral melting after trabeculectomy. However, trauma and scleral necrosis associated with mitomycin are listed as the main causes.The use of a scleral patch derived from bovine pericardium allows effective suturing and closure of the aqueous leak.

  6. SR and LR Union Suture for the Treatment of Myopic Strabismus Fixus: Is Scleral Fixation Necessary?

    Directory of Open Access Journals (Sweden)

    Carol P. S. Lam

    2015-01-01

    Full Text Available Purpose. To evaluate and compare the effectiveness of scleral fixation SR and LR union suture and nonscleral fixation union suture for the treatment of myopic strabismus fixus. Methods. Retrospective review of 32 eyes of 22 patients with myopic strabismus fixus who had undergone union suture of superior rectus (SR and lateral rectus (LR with or without scleral fixation, and follow-up longer than 6 months at Hong Kong Eye Hospital from 2006 to 2013. Surgical techniques and outcomes in terms of ocular alignment are analyzed. Results. There is significant overall improvement both in postoperative angle of esodeviation (P0.05. Conclusions. Union suture of SR and LR is an effective procedure in correcting myopic strabismus fixus. Fixation of the union suture to the sclera does not improve surgical outcome.

  7. Effect of flurbiprofen sodium on pupillary dilatation during scleral buckling surgery

    Directory of Open Access Journals (Sweden)

    Roysarkar T

    1994-01-01

    Full Text Available Maintenance of pupillary dilatation is necessary for success of scleral buckling procedures. The efficacy of 0.03% flurbiprofen in preventing intraoperative miosis was evaluated by a prospective randomized, double-masked controlled trial of 60 patients. Thirty patients received 0.03% flurbiprofen 6 times at 15 minute intervals 90 minutes preoperatively in addition to the routine dilation regimen. The treated group had a mean pupillary decrease of 1.88 mm and the control group had a decrease of 1.57 mm (p > 0.05. Flurbiprofen did not affect the pupillary size at any step of the surgery. Factors such as age of the patient, lens status, number of cryo applications, duration of surgery, and the size and extent of buckle were assessed. The use of flurbiprofen did not affect the mean pupillary change for any of these groups. Preoperative use of flurbiprofen does not significantly decrease intraoperative miosis during scleral buckling procedures

  8. Trabeculectomy with scleral patch graft for advanced glaucoma in ehler–danlos syndrome

    OpenAIRE

    Dhanya Cheriyath; Shabana Bharathi; Ganesh V Raman

    2016-01-01

    We report a case of secondary glaucoma in Ehler–Danlos syndrome (EDS) Type VI, which was uncontrolled with maximal medical therapy, and was subsequently managed surgically. EDS comprises a subgroup of heritable connective tissue disorders characterized by generalized joint hypermobility, skin hyperextensibility, and tissue fragility. The surgical challenges in these patients are presence of scleral thinning, vascular fragility, and poor wound healing. Surgical intervention such as trabeculect...

  9. THE PERMEABILITY OF THE SCLERAL TISSUE FOR ULTRAVIOLET A IN THE EXPERIMENT

    Directory of Open Access Journals (Sweden)

    M. M. Bikbov

    2017-01-01

    Full Text Available Purpose: to evaluate the permeability of the scleral tissue for ultraviolet A (UVA.Materials and Methods. The study was conducted on 15 cadaver porcine eyes. Rectangular scleral flap 12*15 mm was cut out from each eyeball. The thickness of the sample was measured with a digital caliper. The outer surface of the scleral flap was irradiated with ultraviolet A. A sensor of the UV-radiometer was placed under the sample. It measured the UVA irradiance passing through the sclera. The absorption coefficient of ultraviolet A by the sclera was calculated from the formula derived from the Bouguer-Lambert Beer law: , where  E0 — the absorption coefficient, mm-1;  — irradiance of the transmitted light, mW/cm2; I0 — irradiance of the received light, mW/cm2; — thickness of the sclera, mm.Results. The absorption coefficient of ultraviolet A by the sclera was 4,91±0,43 mm-1. According literature the threshold damaging radiation for retina is 7.7 J/cm2. Substituting these values in the converted formula of the Bouguer-Lambert-Beer law, we can derive an equation for calculating the threshold UVA irradiation dose of the sclera: , where 0 — the threshold UVA irradiation dose of the sclera, J/cm2;  — the base of the natural logarithm; — thickness of the sclera, mm.Conclusion. The absorption coefficient of ultraviolet A by the cadaver porcine sclera is 4,91±0,43 mm-1. The derived formula of the threshold UVA irradiation dose of the sclera calculating allows to avoid the threatening for the retina procedure parameters in the performance of the scleral crosslinking with riboflavin/UVA.

  10. Long-term follow-up after scleral lens fixation in patients with Marfan syndrome.

    Science.gov (United States)

    Luebke, Jan; Reinhard, Thomas; Agostini, Hansjuergen; Boehringer, Daniel; Eberwein, Philipp

    2017-12-06

    The dislocation of the crystalline lens is a common finding in patients with Marfan syndrome (MFS). Scleral intraocular lens (IOL) fixation is an accepted treatment method of this complication. To now, no long-term data on scleral IOL fixation in MFS exist. We present a retrospective study of 27 eyes of 17 MFS patients that underwent scleral lens fixation at our clinic between 1999 and 2012. These patients are compared to an age- and surgeon-matched group of 31 eyes of 27 patients who underwent the same procedure for reasons other than MFS. The median age in the MFS group was 35.4 years versus 35.6 years in the non-MFS group. The median follow-up was 4 years for MFS and 3 years for non-MFS. In the MFS group, significantly more IOL-dislocations occurred than compared to the non-MFS group (30% vs. 6.5%, p = 0.02). Retinal detachment occurred in four MFS-eyes compared to three eyes in the non-MFS group. Biometry prediction error was 1.11 diopters (D) for MFS and 1.33 D for non-MFS (p = 0.11). Median BCVA (best-corrected visual acuity, logMAR) was 0.1 in the MFS group versus 0.3 in non-MFS patients. Scleral lens fixation in MFS patients achieves satisfying visual and refractive outcomes. Our data shows a significantly higher rate of IOL dislocations in patients with MFS. We therefore recommend addressing this complication preoperatively.

  11. Scleral necrosis in congenital erythropoietic porphyria: A case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Shweta Agarwal

    2015-01-01

    Full Text Available A 28-year-old presented with complaints of severe pain and redness in the left eye since 2 weeks. He had similar complaints in the right eye 2 years back for which he had undergone a scleral patch graft. Best corrected visual acuity was 20/20 in both eyes. The right had a well vascularized scleral graft and rest of the anterior segment was normal. The left eye had inferior conjunctival congestion with an area of the scleral melt with uveal show just temporal to the limbus in the interpalbebral area. The cornea was clear and anterior chamber was quiet in the left eye. Applanation tonometry and fundus evaluation were normal in both eyes. Physical examination revealed hyperpigmented skin lesion, hypertrichosis and absorption of distal phalanges. Laboratory, ocular and physical findings confirmed the diagnosis of congenital erythropoietic porphyria. He was on oral steroids 40 mg/day since 2 weeks and topical antibiotics and lubricants. He was advised to continue the same and was taken up for scleral patch graft with fibrin glue in the left eye. Postoperatively he was continued on topical and oral steroids and lubricants.3 weeks later the left eye had stabilized however patient came with a melt in the right eye. Since it was an early melt, we went ahead with cyanoacrylate glue and bandage contact lens in the right eye and started him on topical steroids for the right eye also. Three months later both the eyes were stable, and the patient was gradually tapered off the steroids.

  12. Scleral buckling procedure with chandelier illumination for pediatric rhegmatogenous retinal detachment

    OpenAIRE

    Yokoyama, Toshiyuki; Kanbayashi, Koki; Yamaguchi, Tamaki

    2015-01-01

    Toshiyuki Yokoyama, Koki Kanbayashi, Tamaki YamaguchiDepartment of Ophthalmology, Juntendo University Nerima Hospital, Tokyo, JapanPurpose: To assess the treatment of pediatric patients with rhegmatogenous retinal detachment (RRD) by scleral buckling with chandelier illumination.Methods: Three eyes were treated in three patients, healthy boys aged 7 years, 12 years, and 11 years, with RRD, macular involvement, and small retinal holes, of which two were preoperativel...

  13. Extrusion of hydrogel exoplant into upper eyelid 16 years after a scleral buckle procedure

    Directory of Open Access Journals (Sweden)

    Chirag P Shah

    2011-01-01

    Full Text Available Sixteen years after scleral buckle surgery with a hydrogel episcleral exoplant, a 43-year-old woman presented with progressive binocular diplopia, ptosis, and an expanding mass in her upper eyelid. She underwent surgical removal of the hydrogel exoplant through an anterior approach. The exoplant proved to be friable, fragmented, and encapsulated in a fibrous tissue; the exoplant was removed in its entirety. Postoperatively, the eyelid mass resolved, while her diplopia and ptosis improved slightly.

  14. Spots before the eyes: A prevalence and clinicoradiological study of senile scleral plaques

    International Nuclear Information System (INIS)

    Moseley, I.

    2000-01-01

    AIMS: To investigate the prevalence and clinical associations of senile scleral plaques. METHODS: Unselected, consecutive computed tomographic (CT) images of elderly people were reviewed for the presence of calcification indicating senile scleral plaques. RESULTS: No definite calcification was seen in 100 men or 100 women aged 60-69 years; equivocal changes were seen in one woman. There were three definite examples and one equivocal case of calcification in 100 women and four definite cases in 100 men aged 70-79 years. However, in a group of 71 men and women patients aged 80 years or more, 16 definite cases were seen, indicating a prevalence of 22%. CONCLUSIONS: Apart from advanced age, and a mild association with the extent of calcification of the carotid siphon, no clinical or radiological features were identified which consistently characterized a total of 28 patients with this form of ocular calcification; an association with cataract probably reflected simply the recruitment base. Scleral plaques would appear to be a degenerative phenomenon without clinical significance, most likely to be detected in patients presenting with unrelated ophthalmological complaints. Moseley, I. (2000)

  15. Therapeutic use of mini-scleral lenses in a patient with Graves' ophthalmopathy.

    Science.gov (United States)

    Harthan, Jennifer S

    2014-01-01

    Patients with Graves' ophthalmopathy can be very challenging to manage secondary to the complex nature of their disease presentation. Patients may present with a variety of ocular findings including: lid retraction, periorbital and lid swelling, chemosis, conjunctival hyperemia, proptosis, optic neuropathy, restrictive myopathy, exposure keratopathy and/or keratoconjunctivitis sicca. Mini-scleral and scleral lens designs have been important in the management of irregular and regular corneas, and in the therapy of ocular surface diseases. We present here the case of a 48-year-old Caucasian male who had been diagnosed with Graves' ophthalmopathy 13 years earlier. With significant ocular surface staining and over ten diopters of astigmatism, the patient had never been able to wear contact lenses comfortably. After being fit with the Mini-Scleral Design™ lenses, his vision improved to 20/25 OU, his ocular surface improved, and overall quality of vision increased. Copyright © 2012 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  16. The fluid mechanics of scleral buckling surgery for the repair of retinal detachment.

    Science.gov (United States)

    Foster, William Joseph; Dowla, Nadia; Joshi, Saurabh Y; Nikolaou, Michael

    2010-01-01

    Scleral buckling is a common surgical technique used to treat retinal detachments that involves suturing a radial or circumferential silicone element on the sclera. Although this procedure has been performed since the 1960s, and there is a reasonable experimental model of retinal detachment, there is still debate as to how this surgery facilitates the re-attachment of the retina. Finite element calculations using the COMSOL Multiphysics system are utilized to explain the influence of the scleral buckle on the flow of sub-retinal fluid in a physical model of retinal detachment. We found that, by coupling fluid mechanics with structural mechanics, laminar fluid flow and the Bernoulli effect are necessary for a physically consistent explanation of retinal reattachment. Improved fluid outflow and retinal reattachment are found with low fluid viscosity and rapid eye movements. A simulation of saccadic eye movements was more effective in removing sub-retinal fluid than slower, reading speed, eye movements in removing subretinal fluid. The results of our simulations allow us to explain the physical principles behind scleral buckling surgery and provide insight that can be utilized clinically. In particular, we find that rapid eye movements facilitate more rapid retinal reattachment. This is contradictory to the conventional wisdom of attempting to minimize eye movements.

  17. Losartan Treatment Protects Retinal Ganglion Cells and Alters Scleral Remodeling in Experimental Glaucoma

    Science.gov (United States)

    Pitha, Ian F.; Nguyen, Cathy; Steinhart, Matthew R.; Nguyen, Thao D.; Pease, Mary Ellen; Oglesby, Ericka N.; Berlinicke, Cynthia A.; Mitchell, Katherine L.; Kim, Jessica; Jefferys, Joan J.

    2015-01-01

    Purpose To determine if oral losartan treatment decreases the retinal ganglion cell (RGC) death caused by experimental intraocular pressure (IOP) elevation in mice. Methods We produced IOP increase in CD1 mice and performed unilateral optic nerve crush. Mice received oral losartan, spironolactone, enalapril, or no drug to test effects of inhibiting angiotensin receptors. IOP was monitored by Tonolab, and blood pressure was monitored by tail cuff device. RGC loss was measured in masked axon counts and RGC bodies by β-tubulin labeling. Scleral changes that could modulate RGC injury were measured including axial length, scleral thickness, and retinal layer thicknesses, pressure-strain behavior in inflation testing, and study of angiotensin receptors and pathways by reverse transcription polymerase chain reaction, Western blot, and immunohistochemistry. Results Losartan treatment prevented significant RGC loss (median loss = 2.5%, p = 0.13), while median loss with water, spironolactone, and enalapril treatments were 26%, 28% and 43%; p glaucoma eyes (p = 0.007). Losartan inhibited effects of glaucoma, including reduction in extracellular signal-related kinase activity and modification of glaucoma-related changes in scleral thickness and creep under controlled IOP. Conclusions The neuroprotective effect of losartan in mouse glaucoma is associated with adaptive changes in the sclera expressed at the optic nerve head. PMID:26505191

  18. Scleral depressed vitreous shaving, 360 laser, and perfluoropropane (C 3 F 8 for retinal detachment

    Directory of Open Access Journals (Sweden)

    Vivek Chaturvedi

    2014-01-01

    Full Text Available Purpose : To review the characteristics and outcomes of patients who underwent pars plana vitrectomy (PPV with scleral depressed vitreous shaving, 360 degree peripheral endolaser, and 14% C3F8 gas for rhegmatogenous retinal detachment (RRD. Materials and Methods : A retrospective review of a consecutive series of patients who underwent primary repair of RRD by PPV with scleral depressed vitreous shaving, 360 degree peripheral endolaser, and 14% perfluoropropane (C 3 F 8 was conducted. Patients with less than 3 months follow-up, previous retinal surgery, and higher than grade B proliferative vitreoretinopathy were excluded. Results : Ninety-one eyes were included in the study. The mean age was 60.1 years. The mean follow-up was 13.7 months. The macula was detached in 63% (58/91 of the eyes. The reattachment rate after one surgical procedure was 95% (86/91 while overall reattachment rate was 100%. There was no statistically significant difference between reattachment rates of superior, nasal/temporal, or inferior RRDs. The mean final best corrected visual acuity (BCVA was 20/40. Of all the patients, 66% of patients with macula-off RRDs had a final BCVA of 20/40 or better. Conclusions: PPV with scleral depressed vitreous shaving, 360 degree peripheral endolaser, and 14% C 3 F 8 leads to successful anatomical reattachment with visual improvement in patients with primary RRD.

  19. Efficacy of long scleral tunnel technique in preventing Ahmed glaucoma valve tube exposure through conjunctiva.

    Science.gov (United States)

    Kugu, Suleyman; Erdogan, Gurkan; Sevim, M Sahin; Ozerturk, Yusuf

    2015-01-01

    To evaluate the efficacy of long scleral tunnel technique used in Ahmed glaucoma valve (AGV) implantation in preventing tube exposure through conjunctiva. Patients of adult age, who were unresponsive to maximum medical treatment and underwent AGV implantation, were divided into two groups and investigated retrospectively. Group 1 consisted of 40 eyes of 38 patients that underwent surgery by long scleral tunnel technique and Group 2 consisted of 38 eyes of 35 patients that underwent implantation by processed pericardium patch graft method. The mean age was 54.8 ± 14.6 years (range 26-68 years) and the mean follow-up duration was 46.7 ± 19.4 months (range 18-76 months) for the patients in Group 1, whereas the mean age was 58.6 ± 16.7 years (range 32-74 years) and mean follow-up period was 43.6 ± 15.7 months (range 20-72 months) for the patients in Group 2 (p > 0.05). In the course of follow-up, tube exposure was detected in one (2.5%) eye in Group 1 and in three (7.9%) eyes in Group 2 (p = 0.042). Long scleral tunnel technique is beneficial in preventing conjunctival tube exposure in AGV implantation surgery.

  20. Scleral buckling procedure with chandelier illumination for pediatric rhegmatogenous retinal detachment.

    Science.gov (United States)

    Yokoyama, Toshiyuki; Kanbayashi, Koki; Yamaguchi, Tamaki

    2015-01-01

    To assess the treatment of pediatric patients with rhegmatogenous retinal detachment (RRD) by scleral buckling with chandelier illumination. Three eyes were treated in three patients, healthy boys aged 7 years, 12 years, and 11 years, with RRD, macular involvement, and small retinal holes, of which two were preoperatively undetectable. Conventional scleral buckling with cryoretinopexy was performed under the contact lens for vitreous surgery or noncontact wide-angle viewing system using 27-gauge twin chandelier illumination. The only known predisposing factor for retinal detachment was myopia stronger than 3 D with lattice retinal degeneration in two of the three patients. Retinal reattachment was achieved in all cases without intra- or postoperative complications. However, visual recovery was limited in one of the three patients. Scleral buckling with chandelier illumination is effective for pediatric RRD, especially if the retinal hole is difficult to detect preoperatively. However, visual recovery was sometimes limited because of macular involvement due to late diagnosis, which is one of the characteristic features of pediatric RRD.

  1. Pneumatic retinopexy versus scleral buckle for repairing simple rhegmatogenous retinal detachments.

    Science.gov (United States)

    Hatef, Elham; Sena, Dayse F; Fallano, Katherine A; Crews, Jonathan; Do, Diana V

    2015-05-07

    Rhegmatogenous retinal detachment (RRD) is a full-thickness break in the sensory retina, caused by vitreous traction on the retina. While pneumatic retinopexy, scleral buckle, and vitrectomy are the accepted surgical interventions for eyes with RRD, their relative effectiveness has remained controversial.  The objectives of this review were to assess the effectiveness and safety of pneumatic retinopexy versus scleral buckle or pneumatic retinopexy versus a combination treatment of scleral buckle and vitrectomy for people with RRD. The secondary objectives were to summarize any data on economic measures and quality of life. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2014, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to January 2015), EMBASE (January 1980 to January 2015), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to January 2015), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 13 January 2015. We included all randomized or quasi-randomized controlled trials comparing the effectiveness of pneumatic retinopexy versus scleral buckle (with or without vitrectomy) for eyes with RRD. After screening for eligibility, two review authors independently extracted study characteristics, methods, and outcomes. We followed systematic review standards as set forth by The Cochrane Collaboration. We included two randomized controlled trials (218 eyes of 216 participants) comparing the effectiveness of pneumatic retinopexy versus scleral buckle for eyes with RRD. We identified no studies

  2. Scleral Cross-Linking Using Riboflavin UVA Irradiation for the Prevention of Myopia Progression in a Guinea Pig Model: Blocked Axial Extension and Altered Scleral Microstructure.

    Directory of Open Access Journals (Sweden)

    Shuai Liu

    Full Text Available To develop methods of collagen cross-linking (CXL in the sclera for the treatment of progressive myopia and to investigate the biomechanical and histological changes that occur in as a result.Twenty 14-day-old guinea pigs were divided into 3 groups: the cross-linking group (CL, n = 8, non cross-linking group (NCL, n = 8, and control group (n = 4. The scleras of the right eyes of the guinea pigs in the CL group were surgically exposed and riboflavin was dropped onto the irradiation zone for 20 seconds prior to ultraviolet-A (UVA irradiation. The same procedure was conducted on the NCL group but without UVA irradiation. No procedure was conducted on the control group. The right eyes of the guinea pigs in the CL and NCL groups were then fitted with -10.00DS optics for six weeks. Retinoscopy and the axial lengths (AXL were measured at baseline, and at the second, fourth and sixth weeks post-treatment in all three groups. All animal subjects were euthanized after the sixth week and then biomechanical and histopathological examinations of the scleras were conducted.The mean AXL of the NCL group was longer than both the control and CL groups at six weeks (P = 0.001. The mean refractive error in the NCL group was statistically significantly more negative than both the control and the CL groups at six weeks (P = 0.001. The scleral collagen fiber arrangements of the CL and control groups were denser and more regularly distributed than the NCL group. Ultimate stress of the sclera was lowest in the NCL group, followed by the CL then the control group (P<0.05. Ultimate strain (% of the sclera was lowest in the CL group followed by the NCL and then the control group (P<0.05.Our study demonstrates that scleral CXL using riboflavin UVA irradiation effectively prevents the progression of myopia by increasing scleral biomechanical strength in a guinea pig model.

  3. Solvent-free biodegradable scleral plugs providing sustained release of vancomycin, amikacin, and dexamethasone--an in vivo study.

    Science.gov (United States)

    Peng, Yi-Jie; Kau, Yi-Chuan; Wen, Chin-Wei; Liu, Kuo-Sheng; Liu, Shih-Jung

    2010-08-01

    Delivering effective drugs at sufficiently high concentrations to the area of infection is a standard treatment for infectious disease, such as endophthalmitis. This is currently done by empirical trans pars plana intravitreal injection of both antibiotics directed against gram-positive and gram-negative microorganisms and steroids. However, injections by needles repeatedly may increase the risks of intraocular infection and hemorrhage, as well as retinal detachment. This article explores the alternative of using biodegradable polymers as scleral plugs for a long-term drug release in vivo. To manufacture plugs, poly(lactide-glycolide) copolymers were first mixed with vancomycin, amikacin, and dexamethasone. The mixture was compressed and sintered at 55 degrees C to form scleral plugs 1.4 mm in diameter. Biodegradable scleral plugs released high concentrations of antibiotics (well above the minimum inhibitory concentrations, MIC) and steroids in vivo for the period of time needed to treat intraocular infection. In addition, no major complications such as infectious or sterile endophthalmitis, retinal detachment, ocular phthisis, or uvea protrusion at sclerotomy site were observed throughout the experiment. The sclerotomy wound healed after total degradation of the scleral implants without leakage or local necrosis. Antibiotic/steroid-impregnated biodegradable scleral plugs may have a potential role in the treatment of various intraocular infections. (c) 2010 Wiley Periodicals, Inc.

  4. Corneal topographic changes after 20-gauge pars plana vitrectomy associated with scleral buckling for the treatment of rhegmatogenous retinal detachment

    Directory of Open Access Journals (Sweden)

    Alexandre Achille Grandinetti

    2013-04-01

    Full Text Available PURPOSE: To evaluate the changes in corneal topography after 20-gauge pars plana vitrectomy associated with scleral buckling for the repair of rhegmatogenous retinal detachment. METHODS: Twenty-five eyes of 25 patients with rhegmatogenous retinal detachment were included in this study. 20-gauge pars plana vitrectomy associated with scleral buckling was performed in all patients. The corneal topography of each was measured before surgery and one week, one month, and three months after surgery by computer-assisted videokeratoscopy. RESULTS: A statistically significant central corneal steepening (average, 0,9 D , p<0,001 was noted one week after surgery. The total corneal astigmatism had a significant increase in the first postoperative month (p=0,007. All these topographic changes persisted for the first month but returned to preoperative values three months after the surgery. CONCLUSION: Pars plana vitrectomy with scleral buckling was found to induce transient changes in corneal topography.

  5. Trans-scleral selective laser trabeculoplasty (SLT) without a gonioscopy lens (Conference Presentation)

    Science.gov (United States)

    Belkin, Michael; Geffen, Noa; Goldenfeld, Modi; Ofir, Shay; Belkin, Avner; Assia, Ehud

    2016-03-01

    Developing a one-second automatic glaucoma treatment using trans-scleral laser trabeculoplasty (LTP) without a gonioscopy lens Purpose: Developing an LTP device for delivering multiple simultaneous trans-scleral applications of low energy laser irradiation to the trabecular meshwork (TM) for reducing Intraocular Pressure (IOP). Methods: Concept proof: A randomized, masked, controlled one was performed on open angle glaucoma patients. The control group underwent conventional SLT (100 laser spots through a gonioscope for 360 degrees directly on the TM). The trial group underwent irradiation by the same laser at the same irradiation parameters on the sclera overlying the TM. Topical glaucoma therapy was not changed during the 12 months trial. Feasibility trial: Using optimized laser parameters, 60 discrete applications were administered on similar locations of patients' sclera. Results: Concept proof: Trans-scleral applications: (N=15), IOP decrease from 20.21 mmHg before treatment to 16.00 (27.1%) at one year. The corresponding numbers for the control group (n=15), were 21.14 mmHg and 14.30 (23.4%). There was no statistical difference between the two groups in IOP reduction. The complications rate was significantly higher in the control group. Trial 2: IOP was reduced from an of 25.3 mmHg to 19.3 (23.7%) in the 11 patients. Conclusions: Laser coherency, lost in tissue transmission, is not required for the therapeutic effect. The new method will possibly enable treatment of angle closure glaucoma as well as simultaneous applications of all laser spots to the sclera. When used conjointly with target acquisition, will make feasible an automatic glaucoma treatment in less than one second.

  6. Losartan Treatment Protects Retinal Ganglion Cells and Alters Scleral Remodeling in Experimental Glaucoma.

    Directory of Open Access Journals (Sweden)

    Harry A Quigley

    Full Text Available To determine if oral losartan treatment decreases the retinal ganglion cell (RGC death caused by experimental intraocular pressure (IOP elevation in mice.We produced IOP increase in CD1 mice and performed unilateral optic nerve crush. Mice received oral losartan, spironolactone, enalapril, or no drug to test effects of inhibiting angiotensin receptors. IOP was monitored by Tonolab, and blood pressure was monitored by tail cuff device. RGC loss was measured in masked axon counts and RGC bodies by β-tubulin labeling. Scleral changes that could modulate RGC injury were measured including axial length, scleral thickness, and retinal layer thicknesses, pressure-strain behavior in inflation testing, and study of angiotensin receptors and pathways by reverse transcription polymerase chain reaction, Western blot, and immunohistochemistry.Losartan treatment prevented significant RGC loss (median loss = 2.5%, p = 0.13, while median loss with water, spironolactone, and enalapril treatments were 26%, 28% and 43%; p < 0.0001. The lower RGC loss with losartan was significantly less than the loss with spironolactone or enalapril (regression model p = 0.001; drug treatment group term p = 0.01. Both losartan and enalapril significantly lowered blood pressure (p< 0.001, but losartan was protective, while enalapril led to worse than water-treated RGC loss. RGC loss after crush injury was unaffected by losartan treatment (difference from control p = 0.9. Survival of RGC in cell culture was not prolonged by sartan treatment. Axonal transport blockade after 3 day IOP elevations was less in losartan-treated than in control glaucoma eyes (p = 0.007. Losartan inhibited effects of glaucoma, including reduction in extracellular signal-related kinase activity and modification of glaucoma-related changes in scleral thickness and creep under controlled IOP.The neuroprotective effect of losartan in mouse glaucoma is associated with adaptive changes in the sclera expressed at

  7. Trabeculectomy with scleral patch graft for advanced glaucoma in ehler–danlos syndrome

    Directory of Open Access Journals (Sweden)

    Dhanya Cheriyath

    2016-01-01

    Full Text Available We report a case of secondary glaucoma in Ehler–Danlos syndrome (EDS Type VI, which was uncontrolled with maximal medical therapy, and was subsequently managed surgically. EDS comprises a subgroup of heritable connective tissue disorders characterized by generalized joint hypermobility, skin hyperextensibility, and tissue fragility. The surgical challenges in these patients are presence of scleral thinning, vascular fragility, and poor wound healing. Surgical intervention such as trabeculectomy in EDS has not been reported in the literature. With this case report, we share our trials and tribulations in managing this patient with trabeculectomy without antimetabolites, with unexpected modification in the surgery and success.

  8. GoPro HERO 4 Black recording of scleral buckle placement during retinal detachment repair.

    Science.gov (United States)

    Ho, Vincent Y; Shah, Vaishali G; Yates, David M; Shah, Gaurav K

    2017-08-01

    GoPro and Google Glass technology have previously been used to record procedures in ophthalmology and other medical fields. In this manuscript, GoPro's latest HERO 4 Black edition camera (GoPro Inc, San Mateo, Calif.) will be used to record the placement of a scleral buckle during retinal detachment surgery. GoPro HERO 4 Black edition camera, which records 4K-quality video with a resolution of 3840 (pixels) x 2160 (lines), was mounted on a head strap to record placement of a scleral buckle for a retinal detachment. Excellent video quality was achieved with the 4K SuperView setting. Bluetooth connection with an Apple iPad (Apple Inc, Cupertino, Calif.) provided live streaming and use of the GoPro App. Zoom, horizontal/vertical alignment, exposure, and contrast adjustments were made with postproduction editing on GoPro Studio software. Video recording with the GoPro HERO 4 Black edition camera is an excellent way to document extraocular procedures to improve medical education, self-training, or medicolegal documentation. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  9. Posterior chamber lens implantation with scleral fixation in children with traumatic cataract.

    Science.gov (United States)

    Caca, Ihsan; Sahin, Alparslan; Ari, Seyhmus; Alakus, Fuat

    2011-01-01

    To evaluate the outcomes of posterior chamber lens implantation with scleral fixation (SF-PCIOL) in children with traumatic cataract. Twenty-four eyes of 24 cases were included. All patients had corneal or corneoscleral lacerations that were primarily repaired. Traumatic cataract subsequently developed and SF-PCIOL was performed due to insufficient posterior capsule support. The average age of the patients was 5.8 years (range: 4 to 10 years). All cases had SF-PCIOL implanted via internal route using triangular double scleral flaps made of 9-0 polypropylene after a complete anterior vitrectomy. Average follow-up was 14.6 ± 4.3 months (range: 11 to 18 months). Visual acuity was increased at the last visit in 23 (96%) patients. Common postoperative complications were fibrinous reaction in 6 (25%) patients, transient intraocular pressure increase in 4 (17%) patients, membrane formation requiring removal in 1 (4%) patient, transient intraocular hemorrhage as vitreous hemorrhage in 1 (4%) patient, and retinal detachment in 1 (4%) patient after the postoperative second month. SF-PCIOL is an effective and reliable method in patients with pediatric traumatic cataract who had insufficient posterior capsule support. Copyright 2011, SLACK Incorporated.

  10. Binocular Symmetry/Asymmetry of Scleral Redness as a Cue for Sadness, Healthiness, and Attractiveness in Humans

    Directory of Open Access Journals (Sweden)

    Robert R. Provine

    2013-10-01

    Full Text Available Among primates, only humans have the white sclerae that provide the ground necessary to display their own color and that of the overlying conjunctiva. Scleral color, primarily redness, provides cues of socially and biologically significant information about an individual. The present study examines the effect of the asymmetry of binocular scleral redness on perceived sadness, healthiness, and attractiveness by contrasting ratings of images of individuals who had one, both, or neither sclera reddened by digital editing. Building upon previous research, this study further defines the details of the scleral color display and contributes to the more general issue of facial and body symmetry, predictors of phenotypic condition and genotypic quality that are of interest to evolutionary theorists. Individuals with binocular and monocular redness were rated as sadder, less healthy, and less attractive than those with untinted control sclerae, with ratings corresponding to the degree of redness or whiteness. Bilaterally symmetrical (binocular scleral redness or whiteness provided anchorage points for ratings, with ratings for bilaterally asymmetrical (monocular redness or whiteness falling between them; there was no unique effect of asymmetry.

  11. Damage threshold in adult rabbit eyes after scleral cross-linking by riboflavin/blue light application.

    Science.gov (United States)

    Iseli, Hans Peter; Körber, Nicole; Karl, Anett; Koch, Christian; Schuldt, Carsten; Penk, Anja; Liu, Qing; Huster, Daniel; Käs, Josef; Reichenbach, Andreas; Wiedemann, Peter; Francke, Mike

    2015-10-01

    Several scleral cross-linking (SXL) methods were suggested to increase the biomechanical stiffness of scleral tissue and therefore, to inhibit axial eye elongation in progressive myopia. In addition to scleral cross-linking and biomechanical effects caused by riboflavin and light irradiation such a treatment might induce tissue damage, dependent on the light intensity used. Therefore, we characterized the damage threshold and mechanical stiffening effect in rabbit eyes after application of riboflavin combined with various blue light intensities. Adult pigmented and albino rabbits were treated with riboflavin (0.5 %) and varying blue light (450 ± 50 nm) dosages from 18 to 780 J/cm(2) (15 to 650 mW/cm(2) for 20 min). Scleral, choroidal and retinal tissue alterations were detected by means of light microscopy, electron microscopy and immunohistochemistry. Biomechanical changes were measured by shear rheology. Blue light dosages of 480 J/cm(2) (400 mW/cm(2)) and beyond induced pathological changes in ocular tissues; the damage threshold was defined by the light intensities which induced cellular degeneration and/or massive collagen structure changes. At such high dosages, we observed alterations of the collagen structure in scleral tissue, as well as pigment aggregation, internal hemorrhages, and collapsed blood vessels. Additionally, photoreceptor degenerations associated with microglia activation and macroglia cell reactivity in the retina were detected. These pathological alterations were locally restricted to the treated areas. Pigmentation of rabbit eyes did not change the damage threshold after a treatment with riboflavin and blue light but seems to influence the vulnerability for blue light irradiations. Increased biomechanical stiffness of scleral tissue could be achieved with blue light intensities below the characterized damage threshold. We conclude that riboflavin and blue light application increased the biomechanical stiffness of scleral tissue at

  12. Expansions of the neurovascular scleral canal and contained optic nerve occur early in the hypertonic saline rat experimental glaucoma model.

    Science.gov (United States)

    Pazos, Marta; Yang, Hongli; Gardiner, Stuart K; Cepurna, William O; Johnson, Elaine C; Morrison, John C; Burgoyne, Claude F

    2016-04-01

    To characterize early optic nerve head (ONH) structural change in rat experimental glaucoma (EG). Unilateral intraocular pressure (IOP) elevation was induced in Brown Norway rats by hypertonic saline injection into the episcleral veins and animals were sacrificed 4 weeks later by perfusion fixation. Optic nerve cross-sections were graded from 1 (normal) to 5 (extensive injury) by 5 masked observers. ONHs with peripapillary retina and sclera were embedded, serial sectioned, 3-D reconstructed, delineated, and quantified. Overall and animal-specific EG versus Control eye ONH parameter differences were assessed globally and regionally by linear mixed effect models with significance criteria adjusted for multiple comparisons. Expansions of the optic nerve and surrounding anterior scleral canal opening achieved statistical significance overall (p < 0.0022), and in 7 of 8 EG eyes (p < 0.005). In at least 5 EG eyes, significant expansions (p < 0.005) in Bruch's membrane opening (BMO) (range 3-10%), the anterior and posterior scleral canal openings (8-21% and 5-21%, respectively), and the optic nerve at the anterior and posterior scleral canal openings (11-30% and 8-41%, respectively) were detected. Optic nerve expansion was greatest within the superior and inferior quadrants. Optic nerve expansion at the posterior scleral canal opening was significantly correlated to optic nerve damage (R = 0.768, p = 0.042). In the rat ONH, the optic nerve and surrounding BMO and neurovascular scleral canal expand early in their response to chronic experimental IOP elevation. These findings provide phenotypic landmarks and imaging targets for detecting the development of experimental glaucomatous optic neuropathy in the rat eye. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Organo-Selenium Coatings Inhibit Gram-Negative and Gram-Positive Bacterial Attachment to Ophthalmic Scleral Buckle Material.

    Science.gov (United States)

    Tran, Phat; Arnett, Avery; Jarvis, Courtney; Mosley, Thomas; Tran, Khien; Hanes, Rob; Webster, Dan; Mitchell, Kelly; Dominguez, Leo; Hamood, Abdul; Reid, Ted W

    2017-09-01

    Biofilm formation is a problem for solid and sponge-type scleral buckles. This can lead to complications that require removal of the buckle, and result in vision loss due to related ocular morbidity, primarily infection, or recurrent retinal detachment. We investigate the ability of a covalent organo-selenium coating to inhibit biofilm formation on a scleral buckle. Sponge and solid Labtican brand scleral buckles were coated with organo-selenium coupled to a silyation reagent. Staphylococcus aureus biofilm formation was monitored by a standard colony-forming unit assay and the confocal laser scanning microscopy, while Pseudomonas aeruginosa biofilm formation was examined by scanning electron microscopy. Stability studies were done, by soaking in phosphate buffer saline (PBS) at room temperature for 2 months. Toxicity against human corneal epithelial cell was examined by growing the cells in the presence of organo-selenium-coated scleral buckles. The organo-selenium coating inhibited biofilm formation by gram-negative and gram-positive bacteria. The buckle coatings also were shown to be fully active after soaking in PBS for 2 months. The organo-selenium coatings had no effect on the viability of human corneal epithelial cells. Organo-selenium can be used to covalently coat a scleral buckle, which is stable and inhibits biofilm formation for gram-negative and gram-positive bacteria. The organo-selenium buckle coating was stable and nontoxic to cell culture. This technology provides a means to inhibit bacterial attachment to devices attached to the eye, without damage to ocular cells.

  14. Scleral buckling for retinal detachment in Ibadan, Sub-Saharan Africa: anatomical and visual outcome

    Directory of Open Access Journals (Sweden)

    Oluleye TS

    2013-05-01

    Full Text Available TS Oluleye, OA Ibrahim, BA OlusanyaRetina and Vitreous Unit, Department of Ophthalmology, University College Hospital, Ibadan, NigeriaBackground: Scleral buckle surgery is not a commonly performed surgical procedure in Sub-Saharan Africa due to a paucity of trained vitreo retinal surgeons. The aim of the study was to review sclera buckle procedures with a view to evaluating the anatomical and visual outcomes.Methods: Case records of patients that had scleral buckle surgery at the Retina Unit of the University College Hospital, Ibadan, Nigeria, between 2007 and 2010 were reviewed. Information retrieved included patients' demographics, duration of symptoms, and presenting vision. Other information included site of retinal break, extent of retinal detachment, involvement of the fellow eye, and macular involvement. Postoperative retina reattachment and postoperative visual acuity were also recorded. Proportions and percentages were used to analyze data.Results: Forty five eyes of 42 patients were studied with a male to female ratio of 1.6:1. The mean age was 47.7 years (±17.6 years. The median duration before presentation was 3 months (range: 5 days – 156 months. Subtotal retinal detachment was found in 35 eyes (77.8% while total retinal detachment occurred in ten eyes (22.2%. Thirty four eyes (75.6% had "macular off" detachments. At 6 weeks, there was an improvement in visual acuity in 23 eyes (51.1%, while visual acuity remained the same in nine eyes (20% and was worse in 13 eyes (28.9%. Anatomical attachment was seen in 43 eyes (95.6% on the operation table, in 40 eyes (90.9% at first day postoperatively and in 32 eyes (86.5% at 6 weeks after surgery.Conclusion: Outcome of sclera buckle surgery for rhegmatogenous retinal detachment may be improved in developing countries of Sub Sahara Africa if adequate awareness is created to educate the populace on early presentation.Keywords: retinal detachment, scleral buckle surgery, anatomical and visual

  15. Evisceración en estafiloma escleral anterior gigante Evisceration of the giant anterior scleral staphyloma

    Directory of Open Access Journals (Sweden)

    Irene Rojas Rondón

    2010-01-01

    Full Text Available La evisceración es la técnica quirúrgica seleccionada para el tratamiento de muchas afecciones oculares graves como: endoftalmitis, ojo ciego doloroso por trauma crónico, glaucoma absoluto, desprendimiento de retina crónico, uveítis crónica, pthisis bulbi, buftalmos y por razones estéticas. Paciente de 21 años de edad que acude a consulta solicitando mejoría de su apariencia facial. Al examen ocular encontramos aumento de volumen localizado en toda la zona superior del globo ocular desde hora 9 hasta hora 3 del ojo derecho, donde se observaba adelgazamiento escleral con extensas zonas de coroides expuesta, leucoma corneal que ocupaba eje visual y exotropia 30° x Hirshberg, como secuela de trauma ocular. El diagnóstico fue estafiloma escleral anterior en el ojo derecho con riesgo de perforación escleral. La evisceración fue el proceder quirúrgico de elección en este tipo de afección, se colocó implante orbitario, sin complicaciones. Inmediatamente después de la cirugía se coloca conformador en la cavidad y luego de un mes se coloca prótesis ocular. De esta forma se logra mejorar el componente estético así como una adecuada rehabilitación y por ello la calidad de vida de nuestro paciente.Evisceration is the surgical technique selected for the treatment of many serious ocular illnesses such as endophthalmitis, painful blind eye due to chronic trauma, absolute glaucoma, chronic retinal detachment, chronic uveitis, pthisis bulbi, buphthalmos and for aesthetic reasons. A 21 years-old patient went to the doctor's office to request some assistance to improve her facial look. On ocular exam, increased volume located in the upper area of the eyeball from hour 9 to hour 3 of the right eye was observed; also scleral thinning with extensive areas of exposed choroid, corneal leukoma occupying the visual axis and 30° exotropia x Hirshberg, as ocular trauma sequel. The diagnosis was anterior scleral staphyloma with risk of scleral

  16. GENERALIZED NON INFLAMMATORY SCLERAL THINNING IN A CASE NAEVUS OF OTA

    Directory of Open Access Journals (Sweden)

    Nita

    2015-07-01

    Full Text Available A 30 year old female patient came with redness, pain and watering in her left eye since five days. Past history included sudden loss of vision in right eye two years back following birth of a stillborn ba by due to preeclampsia. On examination she had hyperpigmentation of the face and neck. Both the eyes showed patchy hyperpigmentation all around the limbus. Right eye showed 10 degrees of exotropia with afferent pupillary defect. Intraocular pressure was ra ised to 29 mm of Hg. The Right disc C/D ratio was 0.7 with pallor. The left eye showed signs & symptoms suggestive of acute iridocyclitis with normal IOP. Left visual acuity had dropped to 20/60. Further investigation confirmed the patient had generalised non inflammatory scleral thinning on UBM and associated conductive hearing loss. This is therefore an unusual case of Nevus of ota/Ito.

  17. Ab-interno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration

    Directory of Open Access Journals (Sweden)

    Ertugrul Can

    2016-01-01

    Full Text Available Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL. Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes.

  18. Scleral fixation of a subluxated intraocular lens-capsular bag complex through a fibrotic continuous curvilinear capsulorhexis.

    Science.gov (United States)

    Gimbel, Howard V; Brucks, Matthew; Dardzhikova, Albena A; Camoriano, Gerardo D

    2011-04-01

    Several strategies have been devised to manage in-the-bag intraocular lens (IOL) subluxation. We describe a method of fixating the IOL-capsular bag complex to the sclera using the fibrotic ring that develops around the continuous curvilinear capsulorhexis (CCC). Two, preferably 3, double-armed 10-0 polypropylene sutures are passed around the fibrotic CCC rim of the capsule and out the Hoffman scleral pockets and then tied in the scleral tunnels to center the IOL-bag complex. This technique provides an alternative approach to repositioning and fixating the IOL-bag complex that is especially useful in cases in which removal and replacement of the IOL would be difficult. It also provides more than 2-point fixation to achieve perfect IOL centration. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Studies of Scleral Biomechanical Behavior Related to Susceptibility for Retinal Ganglion Cell Loss in Experimental Mouse Glaucoma

    Science.gov (United States)

    Nguyen, Cathy; Cone, Frances E.; Nguyen, Thao D.; Coudrillier, Baptiste; Pease, Mary E.; Steinhart, Matthew R.; Oglesby, Ericka N.; Jefferys, Joan L.; Quigley, Harry A.

    2013-01-01

    Purpose. To study anatomical changes and mechanical behavior of the sclera in mice with experimental glaucoma by comparing CD1 to B6 mice. Methods. Chronic experimental glaucoma for 6 weeks was produced in 2- to 4-month-old CD1 (43 eyes) and B6 mice (42 eyes) using polystyrene bead injection into the anterior chamber with 126 control CD1 and 128 control B6 eyes. Intraocular pressure (IOP) measurements were made with the TonoLab at baseline and after bead injection. Axial length and scleral thickness were measured after sacrifice in the CD1 and B6 animals and compared to length data from 78 eyes of DBA/2J mice. Inflation testing of posterior sclera was conducted, and circumferential and meridional strain components were determined from the displacement response. Results. Experimental glaucoma led to increases in axial length and width by comparison to fellow eyes (6% in CD1 and 10% in B6; all P glaucoma, the remainder of the sclera uniformly thinned in CD1, but thickened in B6. Peripapillary sclera in CD1 controls had significantly greater temporal meridional strain than B6 and had differences in the ratios of meridional to effective circumferential strain from B6 mice. In both CD1 and B6 mice, exposure to chronic IOP elevation resulted in stiffer pressure–strain responses for both the effective circumferential and meridional strains (multivariable regression model, P = 0.01–0.03). Conclusions. Longer eyes, greater scleral strain in some directions at baseline, and generalized scleral thinning after glaucoma were characteristic of CD1 mice that have greater tendency to retinal ganglion cell damage than B6 mice. Increased scleral stiffness after glaucoma exposure in mice mimics findings in monkey and human glaucoma eyes. PMID:23404116

  20. Ocular coherence tomographic examination of postoperative foveal architecture after scleral buckling vs vitrectomy for macular off retinal detachment.

    LENUS (Irish Health Repository)

    Gibran, S K

    2012-02-03

    AIMS: This pilot study uses Optical Coherence Tomography (OCT) imaging to compare the difference in foveal architecture after successful retinal detachment (RD) surgery by scleral buckling or pars plana vitrectomy (PPV). METHODS: Prospective recruitment of patients with macular off RDs. Detachment surgery was undertaken by scleral buckling, external drainage, and air injection (group 1) or by PPV (group 2). Postoperatively patients had clinical examinations and OCT at 1, 3, 6, and 12 months. If abnormalities persisted, a further OCT was obtained at 18 months. RESULTS: Retinal reattachment, including clinical macular reattachment, was achieved in all cases within 24 h postoperatively. In group 1 (n=22), postoperative OCT showed persistent foveal detachment in 63% of cases (n=14) at 1 and 3 months. At 6 and 12 months, 36% (n=8) and 9% (n=2) had a persistent foveal detachment, respectively, and at 18 months, foveal detachment eventually. In group 2 (n=21), postoperative OCT showed an attached fovea in all cases; however, foveal thickening suggesting intraretinal oedema was present in all cases. The oedematous appearance of retina on OCT settled in 1-3 months. No foveal abnormality was seen at 6 and 12 months postoperatively. CONCLUSIONS: A high proportion of patients with successful retinal reattachment surgery by scleral buckling had foveal detachments postoperatively. No cases who had PPV had foveal detachments; however, transient retinal oedema was evident in all cases. The aetiology of these changes is unknown and warrants further investigation, as there is the potential of a long-term effect on vision.

  1. Persistent submacular fluid diagnosed with Optical Coherence Tomography after successful scleral buckle surgery for macula-off retinal detachment

    Science.gov (United States)

    Kovačević, Igor; Radosavljević, Aleksandra; Kalezić, Bojan; Potić, Jelena; Damjanović, Goran; Stefanović, Ivan

    2012-01-01

    The objective of our study was to analyze the presence of persistent submacular fluid after apparently successful scleral buckle surgery for macula-off retinal detachment, using Optical Coherence Tomography (OCT), and to correlate these findings to postoperative visual acuity. Prospective study of consecutive patients hospitalized for macula-off retinal detachment, between February 2008 and April 2010, was carried out at the single referral centre for vitreoretinal surgery in Serbia. Outcomes were evaluated 1, 3, 6 and 12 months postoperatively, using OCT and best corrected visual acuity (BCVA). All 48 patients with macula-off retinal detachment had undergone clinically successful scleral buckle surgery, 3 to 30 days (mean 14.2 ± 6.9) after the onset of symptoms. Reattachment was achieved and one month later, patients were divided in two groups, according to the presence of submacular fluid assessed by OCT group A with detectable residual submacular fluid (40%) and group B without (60%). The mean BCVA one month postoperatively was significantly lower (pmacula-off retinal detachment who had undergone successful scleral buckle surgery could be explained with presence of submacular fluid, diagnosed by OCT. However, final visual outcome was favourable, due to the gradual resorption of submacular fluid in a 12-month-period. PMID:22938546

  2. Comparison of the Keratometric Corneal Astigmatic Power after Phacoemulsification: Clear Temporal Corneal Incision versus Superior Scleral Tunnel Incision

    Directory of Open Access Journals (Sweden)

    Yongqi He

    2009-01-01

    Full Text Available Objective. This is prospective randomized control trial to compare the mean keratometric corneal astigmatism diopter power (not surgical induced astigmatism among preop and one-month and three-month postop phacoemulcification of either a clear temporal corneal incision or a superior scleral tunnel Incision, using only keratometric astigmatic power reading to evaluate the difference between the two cataract surgery incisions. Methods. 120 patients (134 eyes underwent phacoemulcification were randomly assigned to two groups: Group A, the clear temporal corneal incision group, and Group B, the superior scleral tunnel incision group. SPSS11.5 Software was used for statistical analysis to compare the postsurgical changes of cornea astigmatism on keratometry. Results. The changes of corneal astigmatic diopter in Groups A and B after 3 month postop from keratometric reading were 1.04 + 0.76 and 0.94 + 0.27, respectively (=.84>.05, which showed no statistic significance difference. Conclusion. The incision through either temporal clear cornea or superior scleral tunnel in phacoemulcification shows no statistic difference in astigmatism change on keratometry 3-month postop.

  3. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of intraocular lens without conjunctival dissection in managing lens complications.

    Science.gov (United States)

    Yeung, Ling; Wang, Nan-Kai; Wu, Wei-Chi; Chen, Kuan-Jen

    2018-04-23

    To evaluate the safety and efficacy of combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of intraocular lens (IOL) without conjunctival dissection. A retrospective study in Chang Gung Memorial Hospital, Keelung and Taoyuan, Taiwan. Patients receiving combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of IOL without conjunctival dissection were enrolled. The ocular findings, causes of lens complication, surgical procedures, type of IOL used, and complications were documented. We included 40 eyes from 39 patients (27 male, 12 female) with a mean age of 59.5 [standard deviation (±) 14.8] years old. The mean follow-up duration was 6.8 ± 5.4 months. The cause of lens complications was ocular trauma in 24 (60%) eyes, cataract surgery complications in 11 (28%) eyes, and spontaneous subluxation of crystalline lens in 5 (13%) eyes. The overall best corrected visual acuity (BCVA) (logMAR) improved from 1.359 ± 0.735 to 0.514 ± 0.582 (p IOL decentration was found in 3 (8%) eyes and 1 (3%) eye respectively. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of IOL without conjunctival dissection is effective and safe in managing a wide variety of lens complications, with good postoperative comfort and visual recovery. Retrospective study, not applicable.

  4. Effect of laser UV radiation on the eye scleral tissue in patients with open-angle glaucoma

    Science.gov (United States)

    Razhev, A. M.; Iskakov, I. A.; Churkin, D. S.; Orishich, A. M.; Maslov, N. A.; Tsibul'skaya, E. O.; Lomzov, A. A.; Ermakova, O. V.; Trunov, A. N.; Chernykh, V. V.

    2018-05-01

    We report the results of an experimental study of the effect of short-pulse laser UV radiation on the eye scleral tissue. As samples, we used isolated flaps of the eye scleral tissue from the patients with open-angle glaucoma of the second and third stages. The impact was implemented using the radiation of an excimer XeCl laser with a wavelength of 308 nm and a laser with a wavelength tunable within from 210 to 355 nm. Depending on the problem to be solved, the energy density on the surface of the irradiated tissue varied from a fraction of mJ cm-2 to 15 J cm-2. For the first time we studied the optical properties of the intraocular fluid in the UV and blue spectral range. The study of the ablation process under the action of radiation with a wavelength of 308 nm showed that the rate of material evaporation can vary within 24%–30% at an energy density above 7 J cm-2, depending on the glaucoma stage and the individual features of a patient. The excitation–emission matrices of laser-induced fluorescence (LIF) of the eye scleral tissue were studied experimentally using a laser with a wavelength tuned in the range 210–355 nm. We found the differences in the LIF spectra caused by the excitation wavelength and the openangle glaucoma stage.

  5. Scleral wound healing with cross-link technique using riboflavin and ultraviolet A on rabbit eyes

    Directory of Open Access Journals (Sweden)

    Damasceno NA

    2017-07-01

    Full Text Available Nadyr A Damasceno,1 Nadia C Miguel,2 Marcelo Palis Ventura,3 Miguel Burnier Jr,4 Marcos P Avila,5 Eduardo F Damasceno3 1Ophthalmology Department, Hospital Naval Marcílio Dias, 2Laboratory of Neurohistology and Cell Ultrastructure, Instituto de Ciências Biomédicas, Universidade Federal do Rio de Janeiro, Rio de Janeiro, 3Ophthalmology Department, Universidade Federal Fluminense, Niterói, Brazil; 4Ophthalmology Department, McGill University, Montreal, QC, Canada; 5Ophthalmology Department, Universidade Federal de Goiás, Goiania, Brazil Purpose: The aim of study was to evaluate the cross-link using riboflavin and ultraviolet A (UVA for improving scleral wound healing.Materials and methods: This was an experimental study involving four New Zealand rabbits (eight eyes. Therapy procedure was chosen for the right eye and control procedure for the left one. UVA irradiation of 365 nm with a surface irradiance of 3 mW/cm2 and a photosensitizer of riboflavin drops were applied for 30 minutes on the right eye at 2 mm from the limbus. Sclerotomy incision was performed at 2 mm from the limbus in both right (on the cross-link-treated area and left eye. Then, 30 days after surgery, a morphological analysis and histological staining with hematoxylin–eosin and picrosirius red were performed, and the sclerotomy cicatrization of right and left eyes was compared. The variables investigated were as follows: sclerotomy incision pictures and measurements were made using the ImageJ Software. Scleral thickness was measured (employing the anterior optical coherence tomography and the digital caliper. Collagen fiber density stained with picrosirius red staining was measured using the Image Pro Plus software.Results: The morphological analysis showed that in all samples, the right eye presented sclerotomy closure, and in two eyes, among them, there were no visible edges of the sclerotomies incision. The left eye presented sclerotomy closure and incision edges

  6. Scleral ultrastructure and biomechanical changes in rabbits after negative lens application

    Directory of Open Access Journals (Sweden)

    Xiao Lin

    2018-03-01

    Full Text Available AIM: To address the microstructure and biomechanical changes of the sclera of rabbits after negative lens application by spectacle frame apparatus. METHODS: Five New Zealand rabbits of seven weeks post-natal were treated with -8 D lens monocularly over the course of two weeks. Refractive errors and axial length (AXL were measured at the 1st, 7th and 14th days of the induction period. Ultrastructure of sclera was determined with electron microscopy. Biomechanical properties were tested by an Instron 5565 universal testing machine. RESULTS: Lens-induced (LI eyes elongated more rapidly compared with fellow eyes with AXL values of 15.56±0.14 and 15.21±0.14 mm (P<0.01. Fibril diameter was significantly smaller in the LI eyes compared with control ones in the inner, middle, and outer layers (inner layer, 63.533 vs 76.467 nm; middle layer, 92.647 vs 123.984 nm; outer layer, 86.999 vs 134.257 nm, P<0.01, respectively. In comparison with control eyes, macrophage-like cells that engulfed fibroblasts, dilated endoplasmic reticulum, and vacuoles in fibroblasts were observed in the inner and middle stroma in the LI eyes. Ultimate stress and Young’s modulus were lower in the LI eyes compared with those in the control eyes. CONCLUSION: Negative lens application alters eye growth, and results in axial elongation with changes in scleral ultrastructural and mechanical properties.

  7. Post-lens tear turbidity and visual quality after scleral lens wear.

    Science.gov (United States)

    Carracedo, Gonzalo; Serramito-Blanco, Maria; Martin-Gil, Alba; Wang, Zicheng; Rodriguez-Pomar, Candela; Pintor, Jesús

    2017-11-01

    The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (ICRS group) and patients without ICRS (KC group). Distance visual acuity (VA), contrast sensitivity, pachymetry, post-lens tear layer height and post-lens tear layer turbidity (percentage area occupied and number of particles per mm 2 ) were evaluated with optical coherence tomography before and after wearing a scleral lens. A significant increase of turbidity was found in all groups assessed (p turbidity parameters with distance VA but no correlation between turbidity and post-lens tear layer thickness at the beginning was found (p > 0.05). A strong correlation in all groups between the post-lens tear layer at the beginning and differences of tear layer thickness between two measures was also found (p turbidity. © 2017 Optometry Australia.

  8. Sutureless closure of scleral wounds in animal models by the use of laser welded biocompatible patches

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto

    2011-03-01

    The common procedures used to seal the scleral or conjunctival injuries are based on the traditional suturing techniques, that may induce foreign body reaction during the follow up, with subsequent inflammation and distress for the patient. In this work we present an experimental study on the laser welding of biocompatible patches onto ocular tissues, for the closure of surgical or trauma wounds. The study was performed ex vivo in animal models (porcine eyes). A penetrating perforation of the ocular tissue was performed with a surgical knife. The wound walls were approximated, and a biocompatible patch was put onto the outer surface of the tissue, in order to completely cover the wound as a plaster. The patches were prepared with a biocompatible and biodegradable polymer, showing high mechanical strength, good elasticity, high permeability for vapour and gases and rather low biodegradation. During preparation, Indocyanine Green (ICG) was included in the biopolymeric matrix, so that the films presented high absorption at 810 nm. Effective adhesion of the membranes to the ocular tissues was obtained by using diode laser light emitted from an 810 nm diode laser and delivered by means of a 300 μm core diameter optical fiber, to produce spots of local film/tissue adhesion, due to the photothermal effect at the interface. The result is an immediate closure of the wound, thus reducing post-operative complications due to inflammation.

  9. [Choroidal thickness after scleral buckling surgery in macula-off rhegmatogenous retinal detachment].

    Science.gov (United States)

    Akkoyun, I; Pınarcı, E Y; Yesilirmak, N; Yılmaz, G

    2014-10-01

    Enhanced depth imaging (EDI) optical coherence tomography (OCT) provides high-definition cross-sectional images of the choroid. Information on alterations in choroidal thickness (CT) after scleral buckling surgery (SBS) is rare. The medical charts of 122 patients (122 eyes) who underwent SBS for macula-off rhegmatogenous retinal detachment (RRD) were retrospectively analyzed. Patients with a follow-up ≥ 6 months were included. Postoperative EDI-OCT images concerning CT were evaluated 1 week, 1 month and 6 months postoperatively in 4 groups: group 1 cerclage + cryopexy (n = 39 eyes), group 2 cerclage + cryopexy + sponge (n = 28 eyes), group 3 SBS + subretinal fluid drainage (SRD) (n = 25 eyes) and group 4 SBS + sponge + SRD (n = 30 eyes). Subfoveal CT was compared between the groups and with the non-operated fellow eye. Subfoveal CT in groups 1, 2, 3 and 4 was thicker 1 week postoperatively. There were no significant differences between the groups or when comparing the operated eye with the fellow eye 1 and 6 months postoperatively. There were no differences in subfoveal CT 1 and 6 months after SBS between the eye with macula-off RRD and the fellow eye. The use of a sponge or SRD induced no differences concerning subfoveal CT.

  10. [Two cases of retinal detachment following laser in Situ keratomileusis repaired by scleral buckling surgery].

    Science.gov (United States)

    Onguchi, Tatsuya; Eshita, Tadahiko; Mita, Shinji; Ishida, Susumu; Shinoda, Kei; Kitamura, Shizuaki; Kawashima, Shinichi; Inoue, Makoto; Oguchi, Yoshihisa; Toda, Ikuko; Kato, Naoko

    2002-02-01

    As laser in situ keratomileusis (LASIK) becomes the treatment of choice in the field of refractive surgery, postoperative rhegmatogenous retinal detachment has also begun to occur. However, since it has not been reported yet here in Japan, we report two cases of retinal detachment following LASIK with suggestions based on our experience. A 34-year-old male(Case 1) and a 26-year-old male(Case 2) suffered from retinal detachment one month and eight months after LASIK, respectively. Contributing retinal breaks were a horseshoe tear in Case 1 and atrophic holes in the lattice degeneration in Case 2. Each patient underwent partial scleral buckling with no intraoperative complication, resulting in successful retinal reattachment. Postoperatively, myopic changes developed and persisted one month in Case 1 and several months in Case 2. Great attention should be paid to the possibility of postoperative myopia after a repair of retinal detachment following LASIK. Thus, we stress the necessity of close cooperation between LASIK surgeons and vitreoretinal surgeons to settle the matter.

  11. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach

    Directory of Open Access Journals (Sweden)

    Jeroni Nadal

    2015-01-01

    Full Text Available Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a previously looped nonabsorbable polyester suture. Main Outcome Measures. Best corrected visual acuity (BCVA LogMAR, corneal astigmatism, endothelial cell count, IOL stability, and postoperative complications. Results. Mean follow-up time was 18.8 ± 10.9 months. Mean surgery time was 33 ± 2 minutes. Mean BCVA improved from 0.30 ± 0.48 before surgery to 0.18 ± 0.60 (p=0.015 at 1 month, which persisted to 12 months (0.18 ± 0.60. Neither corneal astigmatism nor endothelial cell count showed alterations 1 year after surgery. Complications included IOL subluxation in 1 eye (4%, vitreous hemorrhage in 2 eyes (8%, transient hypotony in 2 eyes (8%, and cystic macular edema in 1 eye (4%. No patients presented retinal detachment. Conclusion. This surgical technique proved successful in the management of dislocated IOL. Functional results were good and the complications were easily resolved.

  12. Scleral Fixation of Posteriorly Dislocated Intraocular Lenses by 23-Gauge Vitrectomy without Anterior Segment Approach.

    Science.gov (United States)

    Nadal, Jeroni; Kudsieh, Bachar; Casaroli-Marano, Ricardo P

    2015-01-01

    Background. To evaluate visual outcomes, corneal changes, intraocular lens (IOL) stability, and complications after repositioning posteriorly dislocated IOLs and sulcus fixation with polyester sutures. Design. Prospective consecutive case series. Setting. Institut Universitari Barraquer. Participants. 25 eyes of 25 patients with posteriorly dislocated IOL. Methods. The patients underwent 23-gauge vitrectomy via the sulcus to rescue dislocated IOLs and fix them to the scleral wall with a previously looped nonabsorbable polyester suture. Main Outcome Measures. Best corrected visual acuity (BCVA) LogMAR, corneal astigmatism, endothelial cell count, IOL stability, and postoperative complications. Results. Mean follow-up time was 18.8 ± 10.9 months. Mean surgery time was 33 ± 2 minutes. Mean BCVA improved from 0.30 ± 0.48 before surgery to 0.18 ± 0.60 (p = 0.015) at 1 month, which persisted to 12 months (0.18 ± 0.60). Neither corneal astigmatism nor endothelial cell count showed alterations 1 year after surgery. Complications included IOL subluxation in 1 eye (4%), vitreous hemorrhage in 2 eyes (8%), transient hypotony in 2 eyes (8%), and cystic macular edema in 1 eye (4%). No patients presented retinal detachment. Conclusion. This surgical technique proved successful in the management of dislocated IOL. Functional results were good and the complications were easily resolved.

  13. Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Ricardo J. Cumba

    2012-01-01

    Full Text Available Purpose. To evaluate intraobserver and interobserver agreement in locating the scleral spur landmark (SSL and anterior chamber angle measurements obtained using Fourier Domain Anterior Segment Optical Coherence Tomography (ASOCT images. Methods. Two independent, masked observers (SR and AZC identified SSLs on ASOCT images from 31 eyes with open and nonopen angles. A third independent reader, NPB, adjudicated SSL placement if identifications differed by more than 80 μm. Nine months later, SR reidentified SSLs. Intraobserver and interobserver agreement in SSL placement, trabecular-iris space area (TISA750, and angle opening distance (AOD750 were calculated. Results. In 84% of quadrants, SR’s SSL placements during 2 sessions were within 80 μm in both the X- and Y-axes, and in 77% of quadrants, SR and AZC were within 80 μm in both axes. In adjudicated images, 90% of all quadrants were within 80 μm, 88% in nonopen-angle eyes, and 92% in open-angle eyes. The intraobserver and interobserver correlation coefficients (with and without adjudication were above 0.9 for TISA750 and AOD750 for all quadrants. Conclusions. Reproducible identification of the SSL from images obtained with FD-ASOCT is possible. The ability to identify the SSL allows reproducible measurement of the anterior chamber angle using TISA750 and AOD750.

  14. Visual acuity after trans-scleral sutured posterior chamber intraocular lens

    International Nuclear Information System (INIS)

    Mahmood, S.A.; Zafar, S.

    2014-01-01

    To determine the changes in visual acuity in patients undergoing Trans-Scleral Sutured Posterior Chamber Intra-Ocular Lens (TSSPCIOL) implantation at a tertiary care hospital in Karachi, Pakistan. Study Design: Case series. Place and Duration of Study: LRBT Tertiary Eye Hospital, Karachi, from January 2006 to December 2010. Methodology: Records of all patients undergoing implantation of TSSPCIOL were reviewed. Patients with diagnosed glaucoma, diabetic retinopathy, macular degeneration, history of recurrent uveitis, corneal haze or central corneal scars were excluded. For the final analysis, 70 eyes out of a total of 75 were selected. Main outcomes of interest were pre and postoperative visual acuities and surgical complications. SPSS 21 was used for data analysis. Results: Pre-operatively, the average Best Spectacle-Corrected Visual Acuity (BSCVA) was 6/36 on the Snellen chart. This improved to 6/12 postoperatively. The mean improvement seen was 2.4 lines on the Snellen chart (p < 0.05). Complications include transient intraocular pressure elevation in 25 eyes (36%), IOL tilt in 4 eyes (7.1%), Cystoid Macular Edema (CME) in 4 eyes (5.7%), vitreous haemorrhage in 2 eyes (2.9%), hyphema in 2 eyes (2.9%), uveitis in 1 eye (1.4%), and retinal detachment 1 eye (1.4%). No IOL subluxation, suture erosion, iris capture, choroidal effusion or endophthalmitis was encountered and no re-operations were needed. Conclusion: TSSPCIOLs are a good management option for patients with aphakia in whom PC IOLs cannot be placed. (author)

  15. Conjunctival impression cytology evaluation of patients with dry eye disease using scleral contact lenses.

    Science.gov (United States)

    Weber, Sarah La Porta; Hazarbassanov, Rossen Mihaylov; Nasaré, Alex; Gomes, José Álvaro Pereira; Hofling-Lima, Ana Luisa

    2017-06-01

    To evaluate conjunctival impression cytology and HLADR expression changes after wearing scleral contact lenses (ScCLs) for moderate to severe dry eye disease (DED). Prospective interventional case series. Forty-one eyes from 25 patients with moderate to severe DED were evaluated for Esclera ScCL treatment. Best-corrected visual acuity (BCVA) and slit-lamp findings were assessed. Impression cytology specimens were obtained from DED patients at the baseline and after wearing ScCLs for 12 months. The impression cytology specimens were analyzed using morphological results score, and HLA-DR positive cells were detected and quantified. The values were compared to assess the IC changes after wearing ScCLs. Forty-one eyes from 25 patients were fitted with ScCLs to manage DED. The underlying diseases were Stevens-Johnson syndrome (22 eyes), Sjogren's syndrome (11 eyes), graft-versus-host disease (2 eyes), dry eye after keratomileusis (2 eyes) and undifferentiated ocular surface disease (4 eyes). The HE-PAS impression cytology score did not differ significantly before and after wearing ScCLs for 12 months in DED patients (p>0.05). The percentage of eyes expressing the HLA-DR antigen in the temporal conjunctiva after wearing ScCL for 12 months significantly increased in patients with Sjogren's syndrome (11.11% to 66.66%; p=0.0498). In groups with Stevens Johnson syndrome and other ocular surface disorders, we did not observe statistically significant differences (p>0.05). The ScCLs did not change the parameters used to evaluate inflammatory processes, which were measured using conjunctival impression cytology and HLA-DR expression, except in Sjogren syndrome, in which there was an unexpected increase in HLA expression. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Scleral Buckling Using a Non-contact Wide-Angle Viewing System with a 25-Gauge Chandelier Endoilluminator.

    Science.gov (United States)

    Jo, Jaehyuck; Moon, Byung Gil; Lee, Joo Yong

    2017-12-01

    To report the outcome of scleral buckling using a non-contact wide-angle viewing system with a 25-gauge chandelier endoilluminator. Retrospective analyses of medical records were performed for 17 eyes of 16 patients with primary rhegmatogenous retinal detachment (RRD) without proliferative vitreoretinopathy who had undergone conventional scleral buckling with cryoretinopexy using the combination of a non-contact wide-angle viewing system and chandelier endoillumination. The patients were eight males and five females with a mean age of 26.8 ± 10.2 (range, 11 to 47) years. The mean follow-up period was 7.3 ± 3.1 months. Baseline best-corrected visual acuity was 0.23 ± 0.28 logarithm of the minimum angle of resolution units. Best-corrected visual acuity at the final visit showed improvement (0.20 ± 0.25 logarithm of the minimum angle of resolution units), but the improvement was not statistically significant (p = 0.722). As a surgery-related complication, there was vitreous loss at the end of surgery in one eye. As a postoperative complication, increased intraocular pressure (four cases) and herpes simplex epithelial keratitis (one case) were controlled postoperatively with eye drops. One case of persistent RRD after primary surgery needed additional vitrectomy, and the retina was postoperatively attached. Scleral buckling with chandelier illumination as a surgical technique for RRD has the advantages of relieving the surgeon's neck pain from prolonged use of the indirect ophthalmoscope and sharing the surgical procedure with another surgical team member. In addition, fine retinal breaks that are hard to identify using an indirect ophthalmoscope can be easily found under the microscope by direct endoillumination. © 2017 The Korean Ophthalmological Society

  17. A comparative study of tissue glue and vicryl suture for conjunctival and scleral closure in conventional 20-gauge vitrectomy.

    Science.gov (United States)

    Batman, C; Ozdamar, Y; Mutevelli, S; Sonmez, K; Zilelioglu, G; Karakaya, J

    2009-06-01

    To describe the use of tissue glue to close scleral and conjunctival wounds, and to compare the clinical outcomes using tissue glue and vicryl suture for closing these areas in conventional 20-gauge (G) vitrectomy. Thirty eyes of 30 patients were included in this study. The indications for vitreoretinal surgery were diabetic vitreous haemorrhage with severe vitreoretinal traction in 10 eyes, retinal detachment and proliferative vitreoretinopathy in 14 eyes, and vitreous opacity in 6 eyes. Tissue glue (Tisseel, Baxter AG Industries, Vienna, Austria) was used to attach scleral and conjunctival wounds in 15 eyes and vicryl sutures in 15 eyes. The patients were allotted into two subgroups as tissue glue group (TG) and vicryl suture group (VG). The sclerotomy sites were evaluated with ultrasound biomicroscopy (UBM) postoperatively in TG. Follow-up period was 2 months. The groups were statistically compared for ocular signs and symptoms by Mann-Whitney U-test. No scleral wound leakage and conjunctival reattachment were observed at the end of the surgical procedure and during the follow-up period. No adverse effects were seen in TG. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of UBM in TG. Patient comfort was significantly higher in TG than VG (P<0.05). Tissue glue has no adverse effects on ocular tissue and can be used as a substitute for suture materials, and the use of tissue glue decreases patient symptoms during the postoperative period after 20-G vitrectomy. Tissue glue can enable to perform sutureless surgery in the conventional 20-G vitrectomy.

  18. Reverse pupillary block after implantation of a scleral-sutured posterior chamber intraocular lens: a retrospective, open study.

    Science.gov (United States)

    Bang, Seung Pil; Joo, Choun-Ki; Jun, Jong Hwa

    2017-03-29

    To report the clinical features of patients with reverse pupillary block (RPB) after scleral-sutured posterior chamber intraocular lens (PC IOL) implantation and biometric changes after laser peripheral iridotomy (LPI). Eight patients attending our hospital's ophthalmology outpatient clinic, who developed RPB after implantation of a scleral-sutured PC IOL due to subluxation of the crystalline lens or IOL, were investigated in this retrospective, observational study. Preoperative evaluations showed angle pigmentation in all cases and iridodonesis in 2 cases. Two subjects had used an α 1A -adrenoceptor antagonist for benign prostatic hyperplasia. Pars plana or anterior partial vitrectomy was performed in all cases. All eyes showed an extremely deep anterior chamber, a concave iris configuration, and contact between the IOL optic and the iris at the pupillary margin. Pupil capture was detected in 2 cases. The mean (± SD) anterior chamber angle (ACA) was 89.91 ± 10.06°, and the anterior chamber depth (ACD) was 4.42 ± 0.16 mm before LPI. After LPI, the iris immediately became flat with a decreased ACA (51.70 ± 2.59°; P = 0.018) and ACD (4.14 ± 0.15 mm; P = 0.012). After LPI, the intraocular pressure decreased from 19.75 ± 3.77 mmHg to 15.63 ± 4.30 mmHg (P = 0.011), and the spherical equivalent decreased from -0.643 ± 0.385 D to - 0.875 ± 0.505 D (P = 0.016). Concomitant vitrectomy, angle pigmentation, and iridodonesis may be risk factors for RPB after scleral-sutured PC IOL implantation. LPI is effective for relieving the RPB.

  19. Scleral Buckling Versus Primary Vitrectomy in the Management of Retinal Detachment Associated with Mild Vitreous Hemorrhage

    Directory of Open Access Journals (Sweden)

    Tansu Erakgün

    2014-03-01

    Full Text Available Objectives: The aim of this study was to compare the surgical impact of scleral buckling (SB and pars plana vitrectomy (PPV on the anatomic results and visual recovery in cases of rhegmatogenous retinal detachment with mild vitreous hemorrhage. Materials and Methods: In this study, we included 78 eyes of 78 phakic patients who underwent primary surgery for rhegmatogenous retinal detachment complicated by mild vitreous hemorrhage (38 eyes by SB,40 eyes by PPV;all patients had been followed for longer than 6 months after surgery. The surgical outcome and the rate of complications were retrospectively compared. Mann-Whitney U-test and chi-square test were used for the statistical analysis. Results: The reattachment rate after the first surgery was 78.9% (30/38 in the SB group and 95% (38/40 in the PPV group. The difference between the groups was statistically significant (p=0.035. Unseen retinal breaks in 4 eyes, malpositioned buckle in 2 eyes and insufficient closure of the break in 2 eyes of SB cases, as well as reopening of the original break in 2 eyes of PPV cases were the causes of failure. Visual improvement in the PPV group was significantly better than in the SB group in the third and sixth postoperative months (p<0.001 and p=0.026, respectively. Peroperative and postoperative complications were as follows: in the SB group-subretinal hemorrhage (5.2%, PVR of grade B or worse (10.5%, macular pucker (7.8%, and postoperative cataract (13%; in the PPV groupiatrogenic breaks (10%, lens damage (5%, PVR of grade B or worse (5%,macular pucker (5%, and postoperative cataract (35%. Conclusion: Even though the high incidence of peroperative complications such as iatrogenic breaks or postoperative complications such as cataract formation was the major drawback, the results indicate that PPV performed to alleviate peripheral vitreoretinal tractions and clear vitreous hemorrhage offers better anatomic and functional results than SB in the management of

  20. The efficacy and safety of a novel posterior scleral reinforcement device in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Yongguang; Zong, Yao; Zheng, Qishan [State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou (China); Qian, Garrett [University of New South Wales (Australia); Qian, Xiaobin; Li, Yujie; Shao, Wanwen [State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou (China); Gao, Qianying, E-mail: gaoqy@mail.sysu.edu.cn [State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou (China)

    2016-05-01

    Purpose: To evaluate the efficacy and safety of posterior scleral reinforcement (PSR) device for myopia suppression in rabbits' eyes. Methods: PSR surgery was performed on the normal 12 8-week-old New Zealand white rabbits' right eyes. To determine efficacy of the device, ophthalmic examination would be taken at pre-operation and post-operation (1 week, 1 month, 3 months, 6 months, and 1 year), such as A-ultrasound, diopter and B-ultrasound. Evaluation of safety were based on the following indicators: intraocular pressure (IOP), slit lamp, fundus photography, fundus fluorescein angiography and pathological examination after surgery. The efficacy and safety of PSR device were evaluated by comparison (treated eyes and contralateral eyes) of pre and post-operation. Results: The novel PSR device could significantly shorten axial length (preoperative axial length: 16.36 ± 0.14 mm, postoperative 1 week, 1 month, 3 months, 6 months and 1 year axial lengths: 15.03 ± 0.28 mm, 15.23 ± 0.32 mm, 15.39 ± 0.31 mm, 15.45 ± 0.22 mm and 15.45 ± 0.22 mm; P = 0.00037 < 0.001) in the treated eyes (right eyes) after surgery. At different postoperative time points, the B-ultrasound images showed that the PSR located in appropriate position and supported the posterior sclera very well. At the same time, IOP of treated eyes kept a relatively stable level (preoperative IOP: 12.56 ± 2.01 mmHg, postoperative IOP: ranging from 11.33 ± 1.23 mmHg to 13.44 ± 2.19 mmHg, P > 0.05) post-operation 1 year. During observation period, there was no significant inflammatory reaction and complications such as anterior chamber flare, empyema, endophthalmitis, vitreous hemorrhage, retina detachment and retinal choroid neovascularization by slit lamp, fundus photography and fundus fluorescein angiography. In addition, there were no pathologic changes be found by comparison treated eyes group and contralateral group eyes based on pathological examinations. Conclusions: In vivo study

  1. Chondrogenesis in scleral stem/progenitor cells and its association with form-deprived myopia in mice.

    Science.gov (United States)

    Wu, Pei-Chang; Tsai, Chia-Ling; Gordon, Gabriel M; Jeong, Shinwu; Itakura, Tatsuo; Patel, Nitin; Shi, Songtao; Fini, M Elizabeth

    2015-01-01

    Previously, we demonstrated that scleral stem/progenitor cells (SSPCs) from mice have a chondrogenic differentiation potential, which is stimulated by transforming growth factor-β (TGF-β). In the present study, we hypothesized that chondrogenesis in the sclera could be a possible mechanism in myopia development. Therefore, we investigated the association of form-deprivation myopia (FDM) with expressions in mice sclera representing the chondrogenic phenotype: collagen type II (Col2) and α-smooth muscle actin (α-SMA). The mRNA levels of α-SMA and Col2 in cultured murine SSPCs during chondrogenesis stimulated by TGF-β2 were determined by real-time quantitative RT-PCR (qRT-PCR). The expression patterns of α-SMA and Col2 were assessed by immunohistochemistry in a three dimensional pellet culture. In an FDM mouse model, a western blot analysis and immunofluorescence study were used to detect the changes in the α-SMA and Col2 protein expressions in the sclera. In the RPE-choroid complex, qRT-PCR was used to detect any changes in the TGF-β mRNA expression. The treatment of SSPCs in vitro with TGF-β2 for 24 h at 1 or 10 ng/ml led to increased levels of both the α-SMA and Col2 expressions. In addition, we observed the formation of cartilage-like pellets from TGF-β2-treated SSPCs. Both α-SMA and Col2 were expressed in the pellet. In an in-vivo study, the α-SMA and Col2 protein expressions were significantly increased in the sclera of FDM eyes in comparison to contralateral control eyes. Similarly, the levels of TGF-β in the RPE-choroid complex of an FDM eye were also significantly elevated. Based on the concept of stem cells possessing multipotent differentiation potentials, scleral chondrogenesis induced by SSPCs may play a role in myopia development. The increased expressions of the cartilage-associated proteins Col2 and α-SMA during scleral chondrogenesis may be potential markers for myopia development. In addition, the increased levels of TGF-β mRNA in

  2. Small Incision Cataract Surgery (SICS with Clear Corneal Incision and SICS with Scleral Incision – A Comparative Study

    Directory of Open Access Journals (Sweden)

    Md Shafiqul Alam

    2014-01-01

    Full Text Available Background: Age related cataract is the leading cause of blindness and visual impairment throughout the world. With the advent of microsurgical facilities simple cataract extraction surgery has been replaced by small incision cataract surgery (SICS with posterior chamber intra ocular lens implant, which can be done either with clear corneal incision or scleral incision. Objective: To compare the post operative visual outcome in these two procedures of cataract surgery. Materials and method: This comparative study was carried out in the department of Ophthalmology, Delta Medical College & Hospital, Dhaka, Bangladesh, during the period of January 2010 to December 2012. Total 60 subjects indicated for age related cataract surgery irrespective of sex with the age range of 40-80 years with predefined inclusion and exclusion criteria were enrolled in the study. Subjects were randomly and equally distributed in 2 groups; Group A for SICS with clear corneal incision and group B for SICS with scleral incision. Post operative visual out come was evaluated by determining visual acuity and astigmatism in different occasions and was compared between groups. Statistical analysis was done by SPSS for windows version12. Results: The highest age incidence (43.3% was found between 61 to 70 years of age group. Among study subjects 40 were male and 20 were female. Preoperative visual acuity and astigmatism were evenly distributed between groups. Regarding postoperative unaided visual outcome, 6/12 or better visual acuity was found in 19.98% cases in group A and 39.6% cases in group B at 1st week. At 6th week 6/6 vision was found in 36.3% in Group A and 56.1% in Group B and 46.2% in group A and 66% in group B without and with correction respectively. With refractive correction, 6/6 vision was attained in 60% subjects of group A and 86.67% of group B at 8th week. Post operative visual acuity was statistically significant in all occasions. Postoperative astigmatism of

  3. Phacoemulsification using iris hooks and scleral fixation of the intraocular lens in patients with secondary glaucoma associated with lens subluxation.

    Science.gov (United States)

    Ma, K T; Lee, H K; Seong, G J; Kim, C Y

    2008-09-01

    We described the techniques and results of phacoemulsification using iris hook and scleral fixation of intraocular lens (IOL) in patients with secondary glaucoma associated with lens subluxation. Eight eyes of seven patients with secondary glaucoma associated with lens dislocation, who had undergone the surgery, were retrospectively reviewed. At a mean of 23.5 months+/-13.6 (SD) after the surgery, the mean best-corrected visual acuity improved from 0.24+/-0.21 to 0.83+/-0.3, and mean intraocular pressure (IOP) was changed from 38.4+/-11.4 to 15.5+/-1.8 mmHg at the final examination. There were no vitreoretinal complications except cystoid macular oedema in one eye. The technique appears to be safe and effective in terms of visual rehabilitation and controlling IOP in patients with secondary glaucoma associated with lens subluxation.

  4. Excessive scleral shrinkage, rather than choroidal thickening, is a major contributor to the development of hypotony maculopathy after trabeculectomy.

    Directory of Open Access Journals (Sweden)

    Mari Sakamoto

    Full Text Available We previously reported that eyes with hypotony maculopathy (HM after trabeculectomy (TLE exhibited more reduction of axial length (AL than those without HM, suggesting that inward collapse of the scleral wall may contribute to the development of HM after TLE. However, we did not evaluate change in choroidal thickness (CT, which could influence AL measures. We compared the magnitude and rate of AL and CT changes in eyes with and without HM by simultaneously measuring these parameters before and after TLE.We enrolled 77 eyes of 77consecutive patients with glaucoma, who underwent TLE between March 2014 and March 2016. Intraocular pressure (IOP, central corneal thickness, keratometry, AL, and CT were measured pre- and postoperatively, up to 6 months. These biometrics were compared in eyes with and without HM.The 14 patients who developed HM were significantly younger than those who did not. The eyes with HM exhibited significantly reduced AL (2.8% compared to those without HM (0.7%. There was no significant difference in CT change between the two groups. The rate of AL reduction was significantly correlated with age, postoperative IOP, and preoperative AL. Post-adjustment logistic regression analysis revealed that eyes with AL reduction rate ≥ 2% had 11.67 higher risk for developing HM (95% confidence interval, 1.28-106.6; P = 0.03.AL reduction rates ≥ 2% were significantly associated with HM. Excessive reduction in AL, which was seen in eyes with HM, was not an artificial measure resulting from choroidal thickening but rather reflected reductions in the anterior-posterior diameter of the eyeball. Inward collapse of the scleral wall leads to redundancy of the chorioretinal tissue, contributing to the development of HM after TLE.

  5. A retrospective study comparing outcomes of primary rhegmatogenous retinal detachment repair by scleral buckling and pars plana vitrectomy in Finland

    Directory of Open Access Journals (Sweden)

    Sahanne S

    2017-03-01

    Full Text Available Sari Sahanne,1 Raimo Tuuminen,2 Jari Haukka,3 Sirpa Loukovaara4 1Department of Anesthesiology, Helsinki University Central Hospital, Helsinki, 2Department of Ophthalmology, Kymenlaakso Central Hospital, Kotka, 3Hjelt Institute, Faculty of Medicine, University of Helsinki, 4Unit of Vitreoretinal Surgery, Department of Ophthalmology, Helsinki University Central Hospital, University of Helsinki, Helsinki, Finland Background: Rhegmatogenous retinal detachment (RRD is the most common form of retinal detachment and an ophthalmic emergency. Here, we compared outcomes of primary RRD eyes operated with conventional scleral buckling (SB with cryoretinopexy to those operated with standard pars plana vitrectomy (PPV. Methods: This is an institutional, retrospective, register-based, observational, comparative study. Based on the surgical procedure, 319 eyes of 319 patients were divided into two groups: SB plus cryotherapy (n=50 and PPV (n=269. Changes in intraocular pressure (IOP and best-corrected visual acuity (BCVA were recorded at 30 days and reoperation rates within 180 days postoperatively. Results: Eyes operated with PPV had less reoperations within the first 180 days as compared with SB eyes (P=0.001, log-rank test; however, changes in IOP were more prominent (mean ± standard deviation: +8.1±8.8 vs. +4.4±7.0 mmHg, respectively; P=0.006. Changes in BCVA did not differ between the surgical procedures. Conclusion: PPV was associated with higher primary anatomic success rates and lower risk of reoperation but significant IOP elevation when compared to SB. These factors should be case-specifically considered when choosing treatment modality for primary RRD. Keywords: rhegmatogenous retinal detachment, vitrectomy, scleral buckling

  6. Effect of rectus recession combined with the rear suspension scleral fixation in patients with restrictive strabismus caused by thyroid associated ophthalmopathy

    Directory of Open Access Journals (Sweden)

    Hai-Hua Qian

    2016-04-01

    Full Text Available AIM: To investigate the therapeutic effect of rectus recession combined with the rear suspension scleral fixation for patients with restrictive strabismus caused by thyroid associated ophthalmopathy(TAO. METHODS: The clinical data of 48 patients(71 eyeswith severe TAO were retrospective analyzed from January 2013 to January 2015.The patients with severe TAO were divided into the exophthalmos(EMgroup with 25 patients(35 eyes, compressive optic neuropathy(CONgroup with 12 patients(20 eyesand exposure keratopathy(EKgroup with 11 patients(16 eyes.The rectus recession combined with rear suspension scleral fixation treatment was performed in all patients. The visual acuity, clinical activity score(CAS, and diplopia situation of each group were recorded and compared preoperatively and at 6mo postoperatively. RESULTS: The postoperative best corrected visual acuity(BCVAof the three groups were significantly higher than those before operation(PPPPPCONCLUSION: Rectus recession combined with the rear suspension scleral fixation can help improve the restrictive strabismus caused by TAO, visual acuity, eyeballs to roll back, eliminate the diplopia and to improve the life quality of patients.

  7. The Use of the Esclera Scleral Contact Lens in the Treatment of Moderate to Severe Dry Eye Disease.

    Science.gov (United States)

    La Porta Weber, Sarah; Becco de Souza, Rodrigo; Gomes, José Álvaro Pereira; Hofling-Lima, Ana Luisa

    2016-03-01

    To evaluate the efficacy of the Esclera scleral contact lens (SCL) treatment and its impact on clinical testing for moderate to severe dry eye disease (DED). Prospective interventional case series. A total of 41 eyes from 25 patients with moderate to severe DED were evaluated for the Esclera SCL treatment. Best-corrected visual acuity (BCVA), tear osmolarity, the Schirmer I test, tear film breakup time (TBUT), corneal and conjunctival staining, meibomian grading, and Ocular Surface Disease Index and SF-36v2 questionnaires were assessed before and after the SCL treatment. These values were compared to assess the real benefit of using SCL as a treatment for DED. Forty-one eyes from 25 patients were fitted with SCL for management of DED. The underlying diseases were Stevens-Johnson syndrome (22 eyes), Sjogren syndrome (11 eyes), graft-vs-host disease (2 eyes), dry eye after keratomileusis in situ (2 eyes), and undifferentiated ocular surface disease (4 eyes). BCVA improved from 0.703 ± 0.55 logMAR with habitual correction to 0.406 ± 0.43 logMAR with SCL (P dry eye symptoms and quality of life as assessed by the OSDI and SF-36v2 questionnaires (both with P dry eye symptoms, and quality of life. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. SCLERAL BUCKLING VERSUS VITRECTOMY IN THE MANAGEMENT OF MACULA-OFF PRIMARY RHEGMATOGENOUS RETINAL DETACHMENT: A COMPARISON OF VISUAL OUTCOMES.

    Science.gov (United States)

    Wong, Chee Wai; Yeo, Ian Yew San; Loh, Boon Kwang; Wong, Edmund Yick Mun; Wong, Doric Wen Kuan; Ong, Sze Guan; Ang, Chong Lye; Lee, Shu Yen

    2015-12-01

    To compare visual outcomes between pars plana vitrectomy (PPV) with or without scleral buckling (SB) and SB alone in the management of uncomplicated macula-off primary rhegmatogenous retinal detachment. Case-control study of 723 patients with uncomplicated macula-off primary rhegmatogenous retinal detachment seen at the Singapore National Eye Centre from 2005 to 2011. The primary outcome measure was the proportion of eyes achieving functional success, defined as logMAR best-corrected visual acuity of ≤0.3 logMAR at 6 months postoperatively. Multivariable logistic regression analysis was performed adjusting for the following preoperative covariates: age, gender, race, lens status, number of tears found, presence of proliferative vitreoretinopathy, operative procedure, logMAR best-corrected visual acuity, and duration of symptoms. Three hundred and eight eyes underwent SB alone, and 415 eyes underwent PPV ± SB. In the SB group, 133 eyes (43.2%) achieved functional success compared with 116 eyes (28.0%) in the PPV ± SB group. This difference was statistically significant on both univariate (P macula-off primary rhegmatogenous retinal detachment.

  9. A retrospective study comparing outcomes of primary rhegmatogenous retinal detachment repair by scleral buckling and pars plana vitrectomy in Finland.

    Science.gov (United States)

    Sahanne, Sari; Tuuminen, Raimo; Haukka, Jari; Loukovaara, Sirpa

    2017-01-01

    Rhegmatogenous retinal detachment (RRD) is the most common form of retinal detachment and an ophthalmic emergency. Here, we compared outcomes of primary RRD eyes operated with conventional scleral buckling (SB) with cryoretinopexy to those operated with standard pars plana vitrectomy (PPV). This is an institutional, retrospective, register-based, observational, comparative study. Based on the surgical procedure, 319 eyes of 319 patients were divided into two groups: SB plus cryotherapy (n=50) and PPV (n=269). Changes in intraocular pressure (IOP) and best-corrected visual acuity (BCVA) were recorded at 30 days and reoperation rates within 180 days postoperatively. Eyes operated with PPV had less reoperations within the first 180 days as compared with SB eyes ( P =0.001, log-rank test); however, changes in IOP were more prominent (mean ± standard deviation: +8.1±8.8 vs. +4.4±7.0 mmHg, respectively; P =0.006). Changes in BCVA did not differ between the surgical procedures. PPV was associated with higher primary anatomic success rates and lower risk of reoperation but significant IOP elevation when compared to SB. These factors should be case-specifically considered when choosing treatment modality for primary RRD.

  10. Expression of Wnt/β-Catenin Signaling Pathway and Its Regulatory Role in Type I Collagen with TGF-β1 in Scleral Fibroblasts from an Experimentally Induced Myopia Guinea Pig Model

    Directory of Open Access Journals (Sweden)

    Min Li

    2016-01-01

    Full Text Available Background. To investigate Wnt/β-catenin signaling pathway expression and its regulation of type I collagen by TGF-β1 in scleral fibroblasts from form-deprivation myopia (FDM guinea pig model. Methods. Wnt isoforms were examined using genome microarrays. Scleral fibroblasts from FDM group and self-control (SC group were cultured. Wnt isoforms, β-catenin, TGF-β1, and type I collagen expression levels were examined in the two groups with or without DKK-1 or TGF-β1 neutralizing antibody. Results. For genome microarrays, the expression of Wnt3 in FDM group was significantly greater as confirmed in retinal and scleral tissue. The expression of Wnt3 and β-catenin significantly increased in FDM group and decreased significantly with DKK-1. TGF-β1 expression level decreased significantly in FDM group and increased significantly with DKK-1. Along with morphological misalignment inside and outside cells, the amount of type I collagen decreased in FDM group. Furthermore, type I collagen increased and became regular in DKK-1 intervention group, whereas it decreased and rearranged more disorder in TGF-β1 neutralizing antibody intervention group. Conclusions. The activation of Wnt3/β-catenin signaling pathway was demonstrated in primary scleral fibroblasts in FDM. This pathway further reduced the expression of type I collagen by TGF-β1, which ultimately played a role in scleral remodeling during myopia development.

  11. Ion channeling

    International Nuclear Information System (INIS)

    Erramli, H.; Blondiaux, G.

    1994-01-01

    Channeling phenomenon was predicted, many years ago, by stark. The first channeling experiments were performed in 1963 by Davies and his coworkers. Parallely Robinson and Oen have investigated this process by simulating trajectories of ions in monocrystals. This technique has been combined with many methods like Rutherford Backscattering Spectrometry (R.B.S.), Particles Induced X-rays Emission (P.I.X.E) and online Nuclear Reaction (N.R.A.) to localize trace elements in the crystal or to determine crystalline quality. To use channeling for material characterization we need data about the stopping power of the incident particle in the channeled direction. The ratios of channeled to random stopping powers of silicon for irradiation in the direction have been investigated and compared to the available theoretical results. We describe few applications of ion channeling in the field of materials characterization. Special attention is given to ion channeling combined with Charged Particle Activation Analysis (C.P.A.A.) for studying the behaviour of oxygen atoms in Czochralski silicon lattices under the influence of internal gettering and in different gaseous atmospheres. Association between ion channeling and C.P.A.A was also utilised for studying the influence of the growing conditions on concentration and position of carbon atoms at trace levels in the MOVPE Ga sub (1-x) Al sub x lattice. 6 figs., 1 tab., 32 refs. (author)

  12. Channel box

    International Nuclear Information System (INIS)

    Tanabe, Akira.

    1993-01-01

    In a channel box of a BWR type reactor, protruding pads are disposed in axial position on the lateral side of a channel box opposing to a control rod and facing the outer side portion of the control rod in a reactor core loaded state. In the initial loading stage of fuel assemblies, channel fasteners and spacer pads are abutted against each other in the upper portion between the channel boxes sandwiching the control rod therebetween. Further, in the lower portion, a gap as a channel for the movement of the control rod is ensured by the support of fuel support metals. If the channel box is bent toward the control rod along with reactor operation, the pads are abutted against each other to always ensure the gap through which the control rod can move easily. Further, when the pads are brought into contact with each other, the bending deformation of the channel box is corrected by urging to each other. Thus, the control rod can always be moved smoothly to attain reactor safety operation. (N.H.)

  13. Delayed manifestation of bilateral scleral thinning after I-BRITE® procedure and review of literature for cosmetic eye-whitening procedures

    Science.gov (United States)

    Moshirfar, Majid; McCaughey, Michael V; Fenzl, Carlton R; Santiago-Caban, Luis; Kramer, Gregory D; Mamalis, Nick

    2015-01-01

    Purpose To report a case of delayed-onset bilateral scleral thinning and calcium deposition following a cosmetic ocular-whitening procedure (I-BRITE®). Methods A 33-year-old male patient with a history of right-sided ptosis repair and left-sided anterior uveitis had previously undergone bilateral I-BRITE treatment for chronic conjunctival hyperemia. Four years after the procedure, the patient was referred to our institution with bilateral scleral thinning and overlying calcific depositions. A literature review was performed through PubMed from 1980 through 2014 using the search terms ‘cosmetic’, ‘ocular’, ‘conjunctivectomy’, ‘regional conjunctivectomy’, ‘I-BRITE’, ‘eye-whitening’, ‘scleritis’, ‘necrotizing scleritis’, ‘anterior uveitis’, ‘mitomycin C’, ‘5-fluorouracil’, and ‘bevacizumab’, along with associated cross-referencing from relevant articles. Results Examination of the patient revealed bilateral necrotizing scleritis within the nasal region of both eyes. Calcified plaques were also present within the areas of scleromalacia, along with epithelial defects demonstrated with fluorescein staining. Although evidence of previous intraocular inflammation was apparent within the left eye, there were no active signs of inflammation evident within either eye on initial presentation. Complication rates reported in the literature include: scleral thinning (1.8%), calcific plaque formation (2.9%), fibrovascular proliferation (13%), diplopia (1.2%), elevation of intraocular pressure (4.2%), and recurrence of conjunctival hyperemia (2.1%). Conclusion Cosmetic ocular whitening procedures have an attendant high complication rate, and have been associated with several adverse postoperative complications, which have in turn generated several reservations regarding the veritable benefit of the procedure. Many postsurgical complications may demonstrate delayed apparition, varying from several months to several years after primary

  14. Delayed manifestation of bilateral scleral thinning after I-BRITE(®) procedure and review of literature for cosmetic eye-whitening procedures.

    Science.gov (United States)

    Moshirfar, Majid; McCaughey, Michael V; Fenzl, Carlton R; Santiago-Caban, Luis; Kramer, Gregory D; Mamalis, Nick

    2015-01-01

    To report a case of delayed-onset bilateral scleral thinning and calcium deposition following a cosmetic ocular-whitening procedure (I-BRITE(®)). A 33-year-old male patient with a history of right-sided ptosis repair and left-sided anterior uveitis had previously undergone bilateral I-BRITE treatment for chronic conjunctival hyperemia. Four years after the procedure, the patient was referred to our institution with bilateral scleral thinning and overlying calcific depositions. A literature review was performed through PubMed from 1980 through 2014 using the search terms 'cosmetic', 'ocular', 'conjunctivectomy', 'regional conjunctivectomy', 'I-BRITE', 'eye-whitening', 'scleritis', 'necrotizing scleritis', 'anterior uveitis', 'mitomycin C', '5-fluorouracil', and 'bevacizumab', along with associated cross-referencing from relevant articles. Examination of the patient revealed bilateral necrotizing scleritis within the nasal region of both eyes. Calcified plaques were also present within the areas of scleromalacia, along with epithelial defects demonstrated with fluorescein staining. Although evidence of previous intraocular inflammation was apparent within the left eye, there were no active signs of inflammation evident within either eye on initial presentation. Complication rates reported in the literature include: scleral thinning (1.8%), calcific plaque formation (2.9%), fibrovascular proliferation (13%), diplopia (1.2%), elevation of intraocular pressure (4.2%), and recurrence of conjunctival hyperemia (2.1%). Cosmetic ocular whitening procedures have an attendant high complication rate, and have been associated with several adverse postoperative complications, which have in turn generated several reservations regarding the veritable benefit of the procedure. Many postsurgical complications may demonstrate delayed apparition, varying from several months to several years after primary surgical intervention as in the case reported here.

  15. Surface channeling

    International Nuclear Information System (INIS)

    Sizmann, R.; Varelas, C.

    1976-01-01

    There is experimental evidence that swift light ions incident at small angles towards single crystalline surfaces can lose an appreciable fraction of their kinetic energy during reflection. It is shown that these projectiles penetrate into the bulk surface region of the crystal. They can travel as channeled particles along long paths through the solid (surface channeling). The angular distribution and the depth history of the re-emerged projectiles are investigated by computer simulations. A considerable fraction of the penetrating projectiles re-emerges from the crystal with constant transverse energy if the angle of incidence is smaller than the critical angle for axial channeling. Analytical formulae are derived based on a diffusion model for surface channeling. A comparison with experimental data exhibits the relevance of the analytical solutions. (Auth.)

  16. Spark Channels

    Energy Technology Data Exchange (ETDEWEB)

    Haydon, S. C. [Department of Physics, University of New England, Armidale, NSW (Australia)

    1968-04-15

    A brief summary is given of the principal methods used for initiating spark channels and the various highly time-resolved techniques developed recently for studies with nanosecond resolution. The importance of the percentage overvoltage in determining the early history and subsequent development of the various phases of the growth of the spark channel is discussed. An account is then given of the recent photographic, oscillographic and spectroscopic investigations of spark channels initiated by co-axial cable discharges of spark gaps at low [{approx} 1%] overvoltages. The phenomena observed in the development of the immediate post-breakdown phase, the diffuse glow structure, the growth of the luminous filament and the final formation of the spark channel in hydrogen are described. A brief account is also given of the salient features emerging from corresponding studies of highly overvolted spark gaps in which the spark channel develops from single avalanche conditions. The essential differences between the two types of channel formation are summarized and possible explanations of the general features are indicated. (author)

  17. Subretinal Fluid Levels of Signal-Transduction Proteins and Apoptosis Molecules in Macula-Off Retinal Detachment Undergoing Scleral Buckle Surgery.

    Science.gov (United States)

    Carpineto, Paolo; Aharrh-Gnama, Agbeanda; Ciciarelli, Vincenzo; Borrelli, Enrico; Petti, Francesco; Aloia, Raffaella; Lamolinara, Alessia; Di Nicola, Marta; Mastropasqua, Leonardo

    2016-12-01

    To evaluate signal transduction and early apoptosis protein levels in subretinal fluid collected during scleral buckling surgery for macula-off rhegmatogenous retinal detachment (RRD). Our aim was to assess both their relation with RRD features and their influence on the posttreatment outcome. Thirty-three eyes of 33 RRD patients scheduled for scleral buckle surgery were enrolled in the study. Undiluted subretinal fluid samples were collected during surgery and analyzed via magnetic bead-based immunoassay. All patients underwent a complete ophthalmologic evaluation at baseline and at each follow-up visit (months 1, 3, and 6). Moreover, both at baseline and at the postsurgery month 6 visit, the patients were tested by means of spectral-domain optical coherence tomography (SD-OCT) in order to evaluate the average ganglion cell-inner plexiform complex thickness, as well as the photoreceptor inner segment/outer segment junction status. Patients' clinical features (retinal detachment size, detachment duration, and occurrence of proliferative vitreoretinopathy) were associated with several early apoptotic factors (caspase-8, caspase-9, and B-cell lymphoma 2 [Bcl-2]-associated death promoter [BAD]). Furthermore, both early apoptosis factors (caspase-8, Bcl-2, and p53) and signal-transduction proteins (ERK 1/2) were found to influence the postsurgery month 3 OCT characteristics. Signal-transduction proteins and early apoptosis proteins are associated with different clinical features and postsurgery outcomes.

  18. Outcomes of scleral-sutured conventional and aniridia intraocular lens implantation performed in a university hospital setting.

    Science.gov (United States)

    Lockington, David; Ali, Noor Q; Al-Taie, Rasha; Patel, Dipika V; McGhee, Charles N J

    2014-04-01

    To evaluate the outcomes of transscleral sutured posterior chamber intraocular lens (PC IOL) implantation. Public university hospital, Auckland, New Zealand. Retrospective case series. A modified no-touch transscleral sutured PC IOL implantation technique with a 1-piece monofocal IOL (Alcon CZ70BD) or an aniridia IOL (type 67G, Morcher) was assessed. Seventy-eight cases (80.8% men; 53.9% aphakic) were identified. The mean follow-up was 35.5 months and the mean age at surgery, 41 years±21 (SD). The preoperative corrected distance visual acuity (CDVA) was worse than 6/30 in 66.7%. Indications included ocular trauma (46.2%), nontraumatic crystalline lens subluxation (16.7%), post-complicated cataract surgery (10.3%), idiopathic IOL dislocation (10.3%), and congenital cataract/aphakia (10.3%). An aniridia IOL was required in 39.7% of eyes. There were no significant intraoperative complications in 74.4% of eyes. Postoperative complications included transient corneal edema (15.4%), wound leak requiring resuturing (7.7%), retinal detachment (7.7%), and cystoid macular edema (6.4%). One eye (1.3%) developed suture breakage-related late IOL dislocation. Overall, 91.3% of eyes had improved visual acuity or were within 1 line of the presenting CDVA. In eyes with a guarded prognosis, 34.8% achieved a CDVA of 6/12 or better and 43.5% a CDVA of 6/15 to 6/48. In the better prognosis group, 73.9% achieved a CDVA of better than 6/12 and all achieved better than 6/30. Scleral-sutured IOLs achieved good visual outcomes in a public hospital setting. The rate of complications was moderate in this series with a high proportion of severe ocular trauma and a large percentage of aniridia IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. MARKETING CHANNELS

    Directory of Open Access Journals (Sweden)

    Ljiljana Stošić Mihajlović

    2014-07-01

    Full Text Available Marketing channel is a set of entities and institutions, completion of distribution and marketing activities, attend the efficient and effective networking of producers and consumers. Marketing channels include the total flows of goods, money and information taking place between the institutions in the system of marketing, establishing a connection between them. The functions of the exchange, the physical supply and service activities, inherent in the system of marketing and trade. They represent paths which products and services are moving after the production, which will ultimately end up buying and eating by the user.

  20. Delayed manifestation of bilateral scleral thinning after I-BRITE® procedure and review of literature for cosmetic eye-whitening procedures

    Directory of Open Access Journals (Sweden)

    Moshirfar M

    2015-03-01

    Full Text Available Majid Moshirfar,1 Michael V McCaughey,2 Carlton R Fenzl,3 Luis Santiago-Caban,4 Gregory D Kramer,3 Nick Mamalis3 1Department of Ophthalmology, Francis I Proctor Foundation, University of California San Francisco, San Francisco, CA, USA; 2University of New Mexico School of Medicine, Albuquerque, NM, USA; 3John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA; 4Department of Ophthalmology, University of Puerto Rico School of Medicine, San Juan, PR, USA Purpose: To report a case of delayed-onset bilateral scleral thinning and calcium deposition following a cosmetic ocular-whitening procedure (I-BRITE®.Methods: A 33-year-old male patient with a history of right-sided ptosis repair and left-sided anterior uveitis had previously undergone bilateral I-BRITE treatment for chronic conjunctival hyperemia. Four years after the procedure, the patient was referred to our institution with bilateral scleral thinning and overlying calcific depositions. A literature review was performed through PubMed from 1980 through 2014 using the search terms ‘cosmetic’, ‘ocular’, ‘conjunctivectomy’, ‘regional conjunctivectomy’, ‘I-BRITE’, ‘eye-whitening’, ‘scleritis’, ‘necrotizing scleritis’, ‘anterior uveitis’, ‘mitomycin C’, ‘5-fluorouracil’, and ‘bevacizumab’, along with associated cross-referencing from relevant articles.Results: Examination of the patient revealed bilateral necrotizing scleritis within the nasal region of both eyes. Calcified plaques were also present within the areas of scleromalacia, along with epithelial defects demonstrated with fluorescein staining. Although evidence of previous intraocular inflammation was apparent within the left eye, there were no active signs of inflammation evident within either eye on initial presentation. Complication rates reported in the literature include: scleral thinning (1.8%, calcific plaque formation (2.9%, fibrovascular proliferation (13%, diplopia (1

  1. Channel Power in Multi-Channel Environments

    NARCIS (Netherlands)

    M.G. Dekimpe (Marnik); B. Skiera (Bernd)

    2004-01-01

    textabstractIn the literature, little attention has been paid to instances where companies add an Internet channel to their direct channel portfolio. However, actively managing multiple sales channels requires knowing the customers’ channel preferences and the resulting channel power. Two key

  2. A Novel Mgp-Cre Knock-In Mouse Reveals an Anticalcification/Antistiffness Candidate Gene in the Trabecular Meshwork and Peripapillary Scleral Region.

    Science.gov (United States)

    Borrás, Teresa; Smith, Matthew H; Buie, LaKisha K

    2015-04-01

    Soft tissue calcification is a pathological condition. Matrix Gla (MGP) is a potent mineralization inhibitor secreted by cartilage chondrocytes and arteries' vascular smooth muscle cells. Mgp knock-out mice die at 6 weeks due to massive arterial calcification. Arterial calcification results in arterial stiffness and higher systolic blood pressure. Intriguingly, MGP was highly abundant in trabecular meshwork (TM). Because tissue stiffness is relevant to glaucoma, we investigated which additional eye tissues use Mgp's function using knock-in mice. An Mgp-Cre-recombinase coding sequence (Cre) knock-in mouse, containing Mgp DNA plus an internal ribosomal entry site (IRES)-Cre-cassette was generated by homologous recombination. Founders were crossed with Cre-mediated reporter mouse R26R-lacZ. Their offspring expresses lacZ where Mgp is transcribed. Eyes from MgpCre/+;R26RlacZ/+ (Mgp-lacZ knock-in) and controls, 1 to 8 months were assayed for β-gal enzyme histochemistry. As expected, Mgp-lacZ knock-in's TM was intensely blue. In addition, this mouse revealed high specific expression in the sclera, particularly in the peripapillary scleral region (ppSC). Ciliary muscle and sclera above the TM were also positive. Scleral staining was located immediately underneath the choroid (chondrocyte layer), began midsclera and was remarkably high in the ppSC. Cornea, iris, lens, ciliary body, and retina were negative. All mice exhibited similar staining patterns. All controls were negative. Matrix Gla's restricted expression to glaucoma-associated tissues from anterior and posterior segments suggests its involvement in the development of the disease. Matrix Gla's anticalcification/antistiffness properties in the vascular tissue, together with its high TM and ppCS expression, place this gene as a strong candidate for TM's softness and sclera's stiffness regulation in glaucoma.

  3. Channelling and electromagnetic radiation of channelling particles

    International Nuclear Information System (INIS)

    Kalashnikov, N.

    1983-01-01

    A brief description is presented of the channelling of charged particles between atoms in the crystal lattice. The specificities are discussed of the transverse motion of channelling particles as are the origin and properties of quasi-characteristic radiation of channelling particles which accompany transfers from one band of permissible energies of the transverse motion of channelling particles to the other. (B.S.)

  4. Channel Modeling

    Science.gov (United States)

    Schmitz, Arne; Schinnenburg, Marc; Gross, James; Aguiar, Ana

    For any communication system the Signal-to-Interference-plus-Noise-Ratio of the link is a fundamental metric. Recall (cf. Chapter 9) that the SINR is defined as the ratio between the received power of the signal of interest and the sum of all "disturbing" power sources (i.e. interference and noise). From information theory it is known that a higher SINR increases the maximum possible error-free transmission rate (referred to as Shannon capacity [417] of any communication system and vice versa). Conversely, the higher the SINR, the lower will be the bit error rate in practical systems. While one aspect of the SINR is the sum of all distracting power sources, another issue is the received power. This depends on the transmitted power, the used antennas, possibly on signal processing techniques and ultimately on the channel gain between transmitter and receiver.

  5. Channeling experiment

    International Nuclear Information System (INIS)

    Abelin, H.; Birgersson, L.; Widen, H.; Aagren, T.; Moreno, L.; Neretnieks, I.

    1990-07-01

    Channeling of water flow and tracer transport in real fractures in a granite body at Stripa have been investigated experimentally. The experimental site was located 360 m below the ground level. Two kinds of experiments were performed. In the single hole experiments, 20 cm diameter holes were drilled about 2.5 m into the rock in the plane of the fracture. Specially designed packers were used to inject water into the fracture in 5 cm intervals all along the fracture trace in the hole. The variation of the injection flowrates along the fracture were used to determine the transmissivity variations in the fracture plane. Detailed photographs were taken from inside the hole and the visual fracture aperture was compared with the injection flowrates in the same locations. Geostatistical methods were used to evaluate the results. Five holes were measured in great detail. In addition 7 holes were drilled and scanned by simpler packer systems. A double hole experiment was performed where two parallel holes were drilled in the same fracture plane at nearly 2 m distance. Pressure pulse tests were made between the holes in both directions. Tracers were injected in 5 locations in one hole and monitored for in many locations in the other hole. The single hole experiment and the double hole experiment show that most of the fracture planes are tight but that there are open sections which form connected channels over distances of at least 2 meters. It was also found in the double hole experiment that the investigated fracture was intersected by at least one fracture between the two holes which diverted a large amount of the injected tracers to several distant locations at the tunnel wall. (authours)

  6. Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman’s Knot

    Directory of Open Access Journals (Sweden)

    Yong Un Shin

    2017-01-01

    Full Text Available Purpose. To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL using a single fisherman’s knot (SFK. Methods. First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. Results. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. Conclusions. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.

  7. Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman's Knot.

    Science.gov (United States)

    Shin, Yong Un; Seong, Mincheol; Cho, Hee Yoon; Kang, Min Ho

    2017-01-01

    To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) using a single fisherman's knot (SFK). First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage) was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.

  8. Spectral-domain optical coherence tomography analysis of persistent subretinal fluid after scleral buckling surgery for macula-off retinal detachment

    Science.gov (United States)

    Gharbiya, M; Malagola, R; Mariotti, C; Parisi, F; De Vico, U; Ganino, C; Grandinetti, F

    2015-01-01

    Purpose To determine the predictive value of markers for persistent subretinal fluid (SRF) absorption and the influence of subfoveal fluid on visual outcome after scleral buckle (SB) surgery for rhegmatogenous retinal detachment (RRD). Patients and methods This was a retrospective, observational study. We reviewed the medical records of 64 eyes of 64 patients who underwent SB surgery for macula-off RRD. Patients underwent clinical examination and spectral-domain optical coherence tomography before surgery, at 1 month and every 3 months postoperatively. The height and width of SRF bleb(s) were measured over time. Results Persistent SRF at 1 month was observed in 40 eyes (62.5%). SRF blebs were first detected 1.7±2.2 months postoperatively. In 29 cases that could be fully followed up, SRF blebs were completely absorbed 7.8±4.4 months postoperatively. Resolution of fluid was associated with an improvement of VA (P=0.003). Serial measurements of SRF bleb size showed that bleb width decreased significantly at all time points during the 12-month follow-up period (P0.05). The cut-off value of the bleb width-to-height ratio level for predicting bleb absorption at 6 months was 7, with 89% sensitivity and 83% specificity. Conclusions Visual improvement may occur with late resolution of residual subfoveal fluid. A bleb width-to-height ratio >7 indicates a higher risk of SRF to persist beyond 6 months after surgery. PMID:26139048

  9. Small-incision 4-point scleral suture fixation of a foldable hydrophilic acrylic intraocular lens in the absence of capsule support.

    Science.gov (United States)

    Terveen, Daniel C; Fram, Nicole R; Ayres, Brandon; Berdahl, John P

    2016-02-01

    To determine the visual outcomes and complications of a new small-incision technique for 4-point fixation of a hydrophilic acrylic posterior chamber intraocular lens (IOL) in the absence of capsule support. Three North American tertiary referral centers and a private practice. Retrospective case series. Secondary IOL placement was performed from 2011 to 2014. Indications for surgery, clinical results, and complications were analyzed. Primary outcomes included postoperative corrected distance visual acuity (CDVA) and surgical complications. Charts of 35 patients (37 eyes) were reviewed. The mean age at surgery was 56 years, and the mean follow-up was 6 months (range 3 to 24 months). Clinical indications included a dislocated IOL (30%), ocular trauma (19%), crystalline lens subluxation (19%), uveitis-glaucoma-hyphema syndrome (5%), post-complicated cataract (8%), congenital cataract (8%), and decompensated cornea (3%). The mean CDVA improved from 20/80 preoperatively to 20/40 postoperatively (P IOL dislocation (3%). Small-incision 4-point scleral fixation of the Akreos AO60 hydrophilic acrylic IOL in the absence of capsule support appears to be a safe and effective technique for secondary IOL placement. Drs. Berdahl and Ayres are consultants to Bausch & Lomb, Inc. Drs. Ayres and Fram have received speaker fees from Bausch & Lomb. Dr. Terveen does not have a financial or proprietary interest in any material or methods mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Citizens and service channels: channel choice and channel management implications

    NARCIS (Netherlands)

    Pieterson, Willem Jan

    2010-01-01

    The arrival of electronic channels in the 1990s has had a huge impact on governmental service delivery. The new channels have led to many new opportunities to improve public service delivery, not only in terms of citizen satisfaction, but also in cost reduction for governmental agencies. However,

  11. USACE Navigation Channels 2012

    Data.gov (United States)

    California Natural Resource Agency — This dataset represents both San Francisco and Los Angeles District navigation channel lines. All San Francisco District channel lines were digitized from CAD files...

  12. Calcium channel blocker overdose

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002580.htm Calcium-channel blocker overdose To use the sharing features on this page, please enable JavaScript. Calcium-channel blockers are a type of medicine used ...

  13. Quantum Channels With Memory

    International Nuclear Information System (INIS)

    Rybar, T.

    2012-01-01

    Quantum memory channels represent a very general, yet simple and comprehensible model for causal processes. As such they have attracted considerable research interest, mostly aimed on their transfer capabilities and structure properties. Most notably it was shown that memory channels can be implemented via physically naturally motivated collision models. We also define the concept of repeatable channels and show that only unital channels can be implemented repeat ably with pure memory channels. In the special case of qubit channels we also show that every unital qubit channel has a repeatable implementation. We also briefly explore the possibilities of stroboscopical simulation of channels and show that all random unitary channels can be stroboscopically simulated. Particularly in qubit case, all indivisible qubit channels are also random unitary, hence for qubit all indivisible channels can be stroboscopically simulated. Memory channels also naturally capture the framework of correlated experiments. We develop methods to gather and interpret data obtained in such setting and in detail examine the two qubit case. We also show that for control unitary interactions the measured data will never contradict a simple unitary evolution. Thus no memory effects can be spotted then. (author)

  14. Eight channel fast scalar

    Energy Technology Data Exchange (ETDEWEB)

    Waddoup, W D; Stubbs, R J [Durham Univ. (UK)

    1977-11-01

    An eight channel 64-bit scaler has been constructed with a static CMOS memory. Scaling frequencies are independently variable, at each channel, as are the number of bits/channel. The scaler, when used in conjunction with a multichannel charge to time converter results in a very flexible, gated multichannel ADC.

  15. KV7 potassium channels

    DEFF Research Database (Denmark)

    Stott, Jennifer B; Jepps, Thomas Andrew; Greenwood, Iain A

    2014-01-01

    Potassium channels are key regulators of smooth muscle tone, with increases in activity resulting in hyperpolarisation of the cell membrane, which acts to oppose vasoconstriction. Several potassium channels exist within smooth muscle, but the KV7 family of voltage-gated potassium channels have been...

  16. Fine Channel Networks

    Science.gov (United States)

    1997-01-01

    A color image of fine channel networks on Mars; north toward top. The scene shows heavily cratered highlands dissected by dendritic open channel networks that dissect steep slopes of impact crater walls. This image is a composite of Viking high-resolution images in black and white and low-resolution images in color. The image extends from latitude 9 degrees S. to 5 degrees S. and from longitude 312 degrees to 320 degrees; Mercator projection. The dendritic pattern of the fine channels and their location on steep slopes leads to the interpretation that these are runoff channels. The restriction of these types of channels to ancient highland rocks suggests that these channels are old and date from a time on Mars when conditions existed for precipitation to actively erode rocks. After the channels reach a low plain, they appear to end. Termination may have resulted from burial by younger deposits or perhaps the flows percolated into the surface materials and continued underground.

  17. Pars plana vitrectomy compared with pars plana vitrectomy combined with scleral buckle in the primary management of noncomplex rhegmatogenous retinal detachment.

    Science.gov (United States)

    Orlin, Anton; Hewing, Nina J; Nissen, Michael; Lee, Sangwoo; Kiss, Szilard; DʼAmico, Donald J; Chan, R V Paul

    2014-06-01

    To compare pars plana vitrectomy (PPV) with PPV combined with scleral buckle (PPV/SB) in the treatment of primary, noncomplex rhegmatogenous retinal detachment in an academic setting. Retrospective review of 74 consecutive cases that underwent either PPV or PPV/SB for primary rhegmatogenous retinal detachment at New York Presbyterian Hospital, Weill Cornell Medical College. Fifty-two eyes underwent PPV alone while 22 eyes had PPV combined with SB. All eyes had a minimum of 2 months of follow-up. The main outcome measure was single surgery anatomical success. Patients in the PPV/SB group were less likely to be phakic (P = 0.05) and more likely to have an inferior retinal break (P = 0.001) when compared with the PPV group. Between groups, there was no difference in eyes with peripheral retinal lattice degeneration (P = 0.929), multiple breaks (P = 0.801), breaks seen preoperatively (P = 0.095), or those presenting with the macula off retinal detachment (P = 0.548). The majority of patients in both groups underwent small-gauge surgery (23 G or 25 G) (P = 0.65). Attachment of the retina was obtained in 100% of the patients in both groups at most recent follow-up. Single surgery anatomical success was similar between groups (83% PPV vs. 86% PPV/SB; P = 0.695). Mean best-corrected Snellen visual acuity improved in both groups (P = 0.75), with a final best-corrected Snellen visual acuity of 0.418 logMAR in the PPV group and 0.479 logMAR in the PPV/SB group (P = 0.61). When comparing PPV with PPV/SB, no difference in single surgery anatomical success existed after evaluating eyes with inferior breaks (P = 0.68), pseudophakia (P = 0.75), or when small-gauge surgery was performed (P = 0.76). We did not find significant differences in single surgery anatomical success, final anatomical success, or change in visual acuity when comparing PPV with PPV/SB in the repair of primary noncomplex rhegmatogenous retinal detachment in an academic setting where vitreoretinal fellows

  18. Ion channels in plants.

    Science.gov (United States)

    Hedrich, Rainer

    2012-10-01

    Since the first recordings of single potassium channel activities in the plasma membrane of guard cells more than 25 years ago, patch-clamp studies discovered a variety of ion channels in all cell types and plant species under inspection. Their properties differed in a cell type- and cell membrane-dependent manner. Guard cells, for which the existence of plant potassium channels was initially documented, advanced to a versatile model system for studying plant ion channel structure, function, and physiology. Interestingly, one of the first identified potassium-channel genes encoding the Shaker-type channel KAT1 was shown to be highly expressed in guard cells. KAT1-type channels from Arabidopsis thaliana and its homologs from other species were found to encode the K(+)-selective inward rectifiers that had already been recorded in early patch-clamp studies with guard cells. Within the genome era, additional Arabidopsis Shaker-type channels appeared. All nine members of the Arabidopsis Shaker family are localized at the plasma membrane, where they either operate as inward rectifiers, outward rectifiers, weak voltage-dependent channels, or electrically silent, but modulatory subunits. The vacuole membrane, in contrast, harbors a set of two-pore K(+) channels. Just very recently, two plant anion channel families of the SLAC/SLAH and ALMT/QUAC type were identified. SLAC1/SLAH3 and QUAC1 are expressed in guard cells and mediate Slow- and Rapid-type anion currents, respectively, that are involved in volume and turgor regulation. Anion channels in guard cells and other plant cells are key targets within often complex signaling networks. Here, the present knowledge is reviewed for the plant ion channel biology. Special emphasis is drawn to the molecular mechanisms of channel regulation, in the context of model systems and in the light of evolution.

  19. Compound Wiretap Channels

    Directory of Open Access Journals (Sweden)

    Shlomo Shamai (Shitz

    2009-01-01

    Full Text Available This paper considers the compound wiretap channel, which generalizes Wyner's wiretap model to allow the channels to the (legitimate receiver and to the eavesdropper to take a number of possible states. No matter which states occur, the transmitter guarantees that the receiver decodes its message and that the eavesdropper is kept in full ignorance about the message. The compound wiretap channel can also be viewed as a multicast channel with multiple eavesdroppers, in which the transmitter sends information to all receivers and keeps the information secret from all eavesdroppers. For the discrete memoryless channel, lower and upper bounds on the secrecy capacity are derived. The secrecy capacity is established for the degraded channel and the semideterministic channel with one receiver. The parallel Gaussian channel is further studied. The secrecy capacity and the secrecy degree of freedom (s.d.o.f. are derived for the degraded case with one receiver. Schemes to achieve the s.d.o.f. for the case with two receivers and two eavesdroppers are constructed to demonstrate the necessity of a prefix channel in encoder design. Finally, the multi-antenna (i.e., MIMO compound wiretap channel is studied. The secrecy capacity is established for the degraded case and an achievable s.d.o.f. is given for the general case.

  20. Compound Wiretap Channels

    Directory of Open Access Journals (Sweden)

    Kramer Gerhard

    2009-01-01

    Full Text Available Abstract This paper considers the compound wiretap channel, which generalizes Wyner's wiretap model to allow the channels to the (legitimate receiver and to the eavesdropper to take a number of possible states. No matter which states occur, the transmitter guarantees that the receiver decodes its message and that the eavesdropper is kept in full ignorance about the message. The compound wiretap channel can also be viewed as a multicast channel with multiple eavesdroppers, in which the transmitter sends information to all receivers and keeps the information secret from all eavesdroppers. For the discrete memoryless channel, lower and upper bounds on the secrecy capacity are derived. The secrecy capacity is established for the degraded channel and the semideterministic channel with one receiver. The parallel Gaussian channel is further studied. The secrecy capacity and the secrecy degree of freedom ( are derived for the degraded case with one receiver. Schemes to achieve the for the case with two receivers and two eavesdroppers are constructed to demonstrate the necessity of a prefix channel in encoder design. Finally, the multi-antenna (i.e., MIMO compound wiretap channel is studied. The secrecy capacity is established for the degraded case and an achievable is given for the general case.

  1. ATP Release Channels

    Directory of Open Access Journals (Sweden)

    Akiyuki Taruno

    2018-03-01

    Full Text Available Adenosine triphosphate (ATP has been well established as an important extracellular ligand of autocrine signaling, intercellular communication, and neurotransmission with numerous physiological and pathophysiological roles. In addition to the classical exocytosis, non-vesicular mechanisms of cellular ATP release have been demonstrated in many cell types. Although large and negatively charged ATP molecules cannot diffuse across the lipid bilayer of the plasma membrane, conductive ATP release from the cytosol into the extracellular space is possible through ATP-permeable channels. Such channels must possess two minimum qualifications for ATP permeation: anion permeability and a large ion-conducting pore. Currently, five groups of channels are acknowledged as ATP-release channels: connexin hemichannels, pannexin 1, calcium homeostasis modulator 1 (CALHM1, volume-regulated anion channels (VRACs, also known as volume-sensitive outwardly rectifying (VSOR anion channels, and maxi-anion channels (MACs. Recently, major breakthroughs have been made in the field by molecular identification of CALHM1 as the action potential-dependent ATP-release channel in taste bud cells, LRRC8s as components of VRACs, and SLCO2A1 as a core subunit of MACs. Here, the function and physiological roles of these five groups of ATP-release channels are summarized, along with a discussion on the future implications of understanding these channels.

  2. Volume Regulated Channels

    DEFF Research Database (Denmark)

    Klausen, Thomas Kjær

    of volume perturbations evolution have developed system of channels and transporters to tightly control volume homeostasis. In the past decades evidence has been mounting, that the importance of these volume regulated channels and transporters are not restricted to the defense of cellular volume...... but are also essential for a number of physiological processes such as proliferation, controlled cell death, migration and endocrinology. The thesis have been focusing on two Channels, namely the swelling activated Cl- channel (ICl, swell) and the transient receptor potential Vanilloid (TRPV4) channel. I: Cl......- serves a multitude of functions in the mammalian cell, regulating the membrane potential (Em), cell volume, protein activity and the driving force for facilitated transporters giving Cl- and Cl- channels a major potential of regulating cellular function. These functions include control of the cell cycle...

  3. HIPPI and Fibre Channel

    International Nuclear Information System (INIS)

    Tolmie, D.E.

    1992-01-01

    The High-Performance Parallel Interface (HIPPI) and Fibre Channel are near-gigabit per second data communications interfaces being developed in ANSI standards Task Group X3T9.3. HIPPI is the current interface of choice in the high-end and supercomputer arena, and Fibre Channel is a follow-on effort. HIPPI came from a local area network background, and Fibre Channel came from a mainframe to peripheral interface background

  4. Nuclear reactor coolant channels

    International Nuclear Information System (INIS)

    Macbeth, R.V.

    1978-01-01

    Reference is made to coolant channels for pressurised water and boiling water reactors and the arrangement described aims to improve heat transfer between the fuel rods and the coolant. Baffle means extending axially within the channel are provided and disposed relative to the fuel rods so as to restrict flow oscillations occurring within the coolant from being propagated transversely to the axis of the channel. (UK)

  5. New Channels, New Possibilities

    DEFF Research Database (Denmark)

    Pieterson, Willem; Ebbers, Wolfgang; Østergaard Madsen, Christian

    2017-01-01

    In this contribution we discuss the characteristics of what we call the fourth generation of public sector service channels: social robots. Based on a review of relevant literature we discuss their characteristics and place into multi-channel models of service delivery. We argue that social robots......-channel models of service delivery. This is especially relevant given the current lack of evaluations of such models, the broad range of channels available, and their different stages of deployment at governments around the world. Nevertheless, social robots offer an potentially very relevant addition...

  6. Calcium Channel Blockers

    Science.gov (United States)

    ... Certain calcium channel blockers interact with grapefruit products. Kaplan NM, et al. Treatment of hypertension: Drug therapy. In: Kaplan's Clinical Hypertension. 11th ed. Philadelphia, Pa.: Wolters Kluwer ...

  7. A channel profile analyser

    International Nuclear Information System (INIS)

    Gobbur, S.G.

    1983-01-01

    It is well understood that due to the wide band noise present in a nuclear analog-to-digital converter, events at the boundaries of adjacent channels are shared. It is a difficult and laborious process to exactly find out the shape of the channels at the boundaries. A simple scheme has been developed for the direct display of channel shape of any type of ADC on a cathode ray oscilliscope display. This has been accomplished by sequentially incrementing the reference voltage of a precision pulse generator by a fraction of a channel and storing ADC data in alternative memory locations of a multichannel pulse height analyser. Alternative channels are needed due to the sharing at the boundaries of channels. In the flat region of the profile alternate memory locations are channels with zero counts and channels with the full scale counts. At the boundaries all memory locations will have counts. The shape of this is a direct display of the channel boundaries. (orig.)

  8. Management of partial thickness burn of the dorsum skin in a 3-year ...

    African Journals Online (AJOL)

    ml Enrofloxacine, intramuscularly (I.M), 4ml Multivitamin I.M and 4ml Vitamin B complex as supportives. On the second day of presentation, Dermazin® cream was replaced with pure honey® (FUNAAB Consult) for wound dressing. 5ml Vitamin ...

  9. Operative management of partial-thickness tears of the proximal hamstring muscles in athletes.

    Science.gov (United States)

    Bowman, Karl F; Cohen, Steven B; Bradley, James P

    2013-06-01

    Partial tears of the hamstring muscle origin represent a challenging clinical problem to the patient and orthopaedic surgeon. Although nonoperative treatment is frequently met with limited success, there is a paucity of data on the efficacy of surgical management for partial proximal hamstring tears in the active and athletic population. To evaluate the results of an anatomic repair for partial tears of the hamstring muscle origin in athletes. Case series; Level of evidence, 4. The records of 17 patients with partial tears of the proximal hamstring origin were reviewed after institutional review board approval was obtained. All patients were treated with open debridement and primary tendon repair after failure of at least 6 months of nonoperative therapy. Clinical and operative records, radiographs, and magnetic resonance images were reviewed for all patients. A patient-reported outcomes survey was completed by 14 patients that included the Lower Extremity Functional Score (LEFS), Marx activity rating scale, custom LEFS and Marx scales, and subjective patient satisfaction scores. Early and late postoperative complications were recorded. There were 3 male and 14 female patients; their average age was 43 years (range, 19-64 years) and average follow-up was 32 months (range, 12-51 months). There were 2 collegiate athletes (field hockey, track), 14 amateur athletes (distance running, waterskiing, tennis), and a professional bodybuilder. Postoperative LEFS was 73.3 ± 9.9 (range, 50-80) and custom LEFS was 66.7 ± 17.0 (range, 37-80) of a maximum 80 points. The most commonly reported difficulty was with prolonged sitting and explosive direction change while running. The average Marx score was 6.5 ± 5.3 (range, 0-16) of a maximum 16, correlating with a greater return to recreational running activities in this patient cohort than regular participation in pivoting or cutting sports. Marx custom scores were 20 of a maximum 20 in all patients, demonstrating no disability in the operative extremity with activities of daily living. No patient underwent a subsequent surgery. One patient was not satisfied with the result and reported persistent symptoms during competitive distance running. All patients were able to return to their preoperative level of activity after surgery. Anatomic surgical treatment of partial proximal hamstring avulsions can lead to satisfactory functional outcomes, a high rate of return to athletic activity, and low complication rate. This procedure should be reserved for patients who have failed an extended course of nonoperative treatment, and the proximity of the sciatic nerve mandates a careful assessment of the risk-benefit ratio before surgery is undertaken.

  10. Partial thickness autologus calvarial bone orbitocranioplasty for a sphenorbital encephalocele presenting as pulsatile exophthalmos

    OpenAIRE

    Trivedi, Adarsh; Garg, Amrish Kumar; Hiran, Subodh

    2015-01-01

    Basal encephalocele accounts only 1.5% of all encephaloceles. But Sphenorbital encephalocele is the rarest cause of herniation of brain into orbit leading to pulsatile exphothalmos. Authors presenting a case of sphenorbital encephalocele in a 16 yrs old girl successsfully managed by orbitcranioplasty by partilal thickness autologus calvarial bone graft.

  11. A linearization of quantum channels

    Science.gov (United States)

    Crowder, Tanner

    2015-06-01

    Because the quantum channels form a compact, convex set, we can express any quantum channel as a convex combination of extremal channels. We give a Euclidean representation for the channels whose inverses are also valid channels; these are a subset of the extreme points. They form a compact, connected Lie group, and we calculate its Lie algebra. Lastly, we calculate a maximal torus for the group and provide a constructive approach to decomposing any invertible channel into a product of elementary channels.

  12. Omni channel fashion shopping

    NARCIS (Netherlands)

    Kemperman, A.D.A.M.; van Delft, L.; Borgers, A.W.J.; Pantano, E.

    2015-01-01

    This chapter gives insight into consumers' online and offline fashion shopping behavior, consumers' omni-channel usage during the shopping process, and consumer fashion shopper segments. Based on a literature review, omni-channel shopping behavior during the shopping process was operationalized.

  13. Channel electron multipliers

    International Nuclear Information System (INIS)

    Seidman, A.; Avrahami, Z.; Sheinfux, B.; Grinberg, J.

    1976-01-01

    A channel electron multiplier is described having a tubular wall coated with a secondary-electron emitting material and including an electric field for accelerating the electrons, the electric field comprising a plurality of low-resistive conductive rings each alternating with a high-resistive insulating ring. The thickness of the low-resistive rings is many times larger than that of the high-resistive rings, being in the order of tens of microns for the low-resistive rings and at least one order of magnitude lower for the high-resistive rings; and the diameter of the channel tubular walls is also many times larger than the thickness of the high-resistive rings. Both single-channel and multiple-channel electron multipliers are described. A very important advantage, particularly in making multiple-channel multipliers, is the simplicity of the procedure that may be used in constructing such multipliers. Other operational advantages are described

  14. Cardiac potassium channel subtypes

    DEFF Research Database (Denmark)

    Schmitt, Nicole; Grunnet, Morten; Olesen, Søren-Peter

    2014-01-01

    About 10 distinct potassium channels in the heart are involved in shaping the action potential. Some of the K(+) channels are primarily responsible for early repolarization, whereas others drive late repolarization and still others are open throughout the cardiac cycle. Three main K(+) channels...... drive the late repolarization of the ventricle with some redundancy, and in atria this repolarization reserve is supplemented by the fairly atrial-specific KV1.5, Kir3, KCa, and K2P channels. The role of the latter two subtypes in atria is currently being clarified, and several findings indicate...... that they could constitute targets for new pharmacological treatment of atrial fibrillation. The interplay between the different K(+) channel subtypes in both atria and ventricle is dynamic, and a significant up- and downregulation occurs in disease states such as atrial fibrillation or heart failure...

  15. Cl- channels in apoptosis

    DEFF Research Database (Denmark)

    Wanitchakool, Podchanart; Ousingsawat, Jiraporn; Sirianant, Lalida

    2016-01-01

    A remarkable feature of apoptosis is the initial massive cell shrinkage, which requires opening of ion channels to allow release of K(+), Cl(-), and organic osmolytes to drive osmotic water movement and cell shrinkage. This article focuses on the role of the Cl(-) channels LRRC8, TMEM16/anoctamin......, and cystic fibrosis transmembrane conductance regulator (CFTR) in cellular apoptosis. LRRC8A-E has been identified as a volume-regulated anion channel expressed in many cell types. It was shown to be required for regulatory and apoptotic volume decrease (RVD, AVD) in cultured cell lines. Its presence also......(-) channels or as regulators of other apoptotic Cl(-) channels, such as LRRC8. CFTR has been known for its proapoptotic effects for some time, and this effect may be based on glutathione release from the cell and increase in cytosolic reactive oxygen species (ROS). Although we find that CFTR is activated...

  16. CHANNEL ESTIMATION TECHNIQUE

    DEFF Research Database (Denmark)

    2015-01-01

    A method includes determining a sequence of first coefficient estimates of a communication channel based on a sequence of pilots arranged according to a known pilot pattern and based on a receive signal, wherein the receive signal is based on the sequence of pilots transmitted over the communicat......A method includes determining a sequence of first coefficient estimates of a communication channel based on a sequence of pilots arranged according to a known pilot pattern and based on a receive signal, wherein the receive signal is based on the sequence of pilots transmitted over...... the communication channel. The method further includes determining a sequence of second coefficient estimates of the communication channel based on a decomposition of the first coefficient estimates in a dictionary matrix and a sparse vector of the second coefficient estimates, the dictionary matrix including...... filter characteristics of at least one known transceiver filter arranged in the communication channel....

  17. Coherifying quantum channels

    Science.gov (United States)

    Korzekwa, Kamil; Czachórski, Stanisław; Puchała, Zbigniew; Życzkowski, Karol

    2018-04-01

    Is it always possible to explain random stochastic transitions between states of a finite-dimensional system as arising from the deterministic quantum evolution of the system? If not, then what is the minimal amount of randomness required by quantum theory to explain a given stochastic process? Here, we address this problem by studying possible coherifications of a quantum channel Φ, i.e., we look for channels {{{Φ }}}{ \\mathcal C } that induce the same classical transitions T, but are ‘more coherent’. To quantify the coherence of a channel Φ we measure the coherence of the corresponding Jamiołkowski state J Φ. We show that the classical transition matrix T can be coherified to reversible unitary dynamics if and only if T is unistochastic. Otherwise the Jamiołkowski state {J}{{Φ }}{ \\mathcal C } of the optimally coherified channel is mixed, and the dynamics must necessarily be irreversible. To assess the extent to which an optimal process {{{Φ }}}{ \\mathcal C } is indeterministic we find explicit bounds on the entropy and purity of {J}{{Φ }}{ \\mathcal C }, and relate the latter to the unitarity of {{{Φ }}}{ \\mathcal C }. We also find optimal coherifications for several classes of channels, including all one-qubit channels. Finally, we provide a non-optimal coherification procedure that works for an arbitrary channel Φ and reduces its rank (the minimal number of required Kraus operators) from {d}2 to d.

  18. CANDU channel flow verification

    International Nuclear Information System (INIS)

    Mazalu, N.; Negut, Gh.

    1997-01-01

    The purpose of this evaluation was to obtain accurate information on each channel flow that enables us to assess precisely the level of reactor thermal power and, for reasons of safety, to establish which channel is boiling. In order to assess the channel flow parameters, computer simulations were done with the NUCIRC code and the results were checked by measurements. The complete channel flow measurements were made in the zero power cold condition. In hot conditions there were made flow measurements using the Shut Down System 1 (SDS 1) flow devices from 0.1 % F.P. up to 100 % F.P. The NUCIRC prediction for CANDU channel flows and the measurements by Ultrasonic Flow Meter at zero power cold conditions and SDS 1 flow channel measurements at different reactor power levels showed an acceptable agreement. The 100 % F.P. average errors for channel flow of R, shows that suitable NUCIRC flow assessment can be made. So, it can be done a fair prediction of the reactor power distribution. NUCIRC can predict accurately the onset of boiling and helps to warn at the possible power instabilities at high powers or it can detect the flow blockages. The thermal hydraulic analyst has in NUCIRC a suitable tool to do accurate predictions for the thermal hydraulic parameters for different steady state power levels which subsequently leads to an optimal CANDU reactor operation. (authors)

  19. Reconfigurable virtual electrowetting channels.

    Science.gov (United States)

    Banerjee, Ananda; Kreit, Eric; Liu, Yuguang; Heikenfeld, Jason; Papautsky, Ian

    2012-02-21

    Lab-on-a-chip systems rely on several microfluidic paradigms. The first uses a fixed layout of continuous microfluidic channels. Such lab-on-a-chip systems are almost always application specific and far from a true "laboratory." The second involves electrowetting droplet movement (digital microfluidics), and allows two-dimensional computer control of fluidic transport and mixing. The merging of the two paradigms in the form of programmable electrowetting channels takes advantage of both the "continuous" functionality of rigid channels based on which a large number of applications have been developed to date and the "programmable" functionality of digital microfluidics that permits electrical control of on-chip functions. In this work, we demonstrate for the first time programmable formation of virtual microfluidic channels and their continuous operation with pressure driven flows using an electrowetting platform. Experimental, theoretical, and numerical analyses of virtual channel formation with biologically relevant electrolyte solutions and electrically-programmable reconfiguration are presented. We demonstrate that the "wall-less" virtual channels can be formed reliably and rapidly, with propagation rates of 3.5-3.8 mm s(-1). Pressure driven transport in these virtual channels at flow rates up to 100 μL min(-1) is achievable without distortion of the channel shape. We further demonstrate that these virtual channels can be switched on-demand between multiple inputs and outputs. Ultimately, we envision a platform that would provide rapid prototyping of microfluidic concepts and would be capable of a vast library of functions and benefitting applications from clinical diagnostics in resource-limited environments to rapid system prototyping to high throughput pharmaceutical applications.

  20. Evaluation channel performance in multichannel environments

    NARCIS (Netherlands)

    Gensler, S.; Dekimpe, M.; Skiera, B.

    2007-01-01

    Evaluating channel performance is crucial for actively managing multiple sales channels, and requires understanding the customers' channel preferences. Two key components of channel performance are (i) the existing customers' intrinsic loyalty to a particular channel and (ii) the channel's ability

  1. Channel follower leakage restrictor

    International Nuclear Information System (INIS)

    Williamson, H.E.; Smith, B.A.

    1977-01-01

    An improved means is provided to control coolant leakage between the flow channel and the lower tie plate of a nuclear fuel assembly. The means includes an opening in the lower tie plate and a movable element adjacent thereto. The coolant pressure within the tie plate biases the movable means toward the inner surface of the surrounding flow channel to compensate for any movement of the flow channel away from the lower tie plate to thereby control the leakage of coolant flow from the fuel assemblies to the spaces among the fuel assemblies of the core. 9 figures

  2. Direct channel problems and phenomena

    International Nuclear Information System (INIS)

    Cutkosky, R.E.

    1975-01-01

    Direct channel problems and phenomena are considered covering the need for precision hadron spectroscopy, the data base for precision hadron spectroscopy, some relations between direct-channel and cross-channel effects, and spin rotation phenomena

  3. Many channel spectrum unfolding

    International Nuclear Information System (INIS)

    Najzer, M.; Glumac, B.; Pauko, M.

    1980-01-01

    The principle of the ITER unfolding code as used for the many channel spectrum unfolding is described. Its unfolding ability is tested on seven typical neutron spectra. The effect of the initial spectrum approximation upon the solution is discussed

  4. Channelized Streams in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This draft dataset consists of all ditches or channelized pieces of stream that could be identified using three input datasets; namely the1:24,000 National...

  5. Coding for optical channels

    CERN Document Server

    Djordjevic, Ivan; Vasic, Bane

    2010-01-01

    This unique book provides a coherent and comprehensive introduction to the fundamentals of optical communications, signal processing and coding for optical channels. It is the first to integrate the fundamentals of coding theory and optical communication.

  6. Sensing with Ion Channels

    CERN Document Server

    Martinac, Boris

    2008-01-01

    All living cells are able to detect and translate environmental stimuli into biologically meaningful signals. Sensations of touch, hearing, sight, taste, smell or pain are essential to the survival of all living organisms. The importance of sensory input for the existence of life thus justifies the effort made to understand its molecular origins. Sensing with Ion Channels focuses on ion channels as key molecules enabling biological systems to sense and process the physical and chemical stimuli that act upon cells in their living environment. Its aim is to serve as a reference to ion channel specialists and as a source of new information to non specialists who want to learn about the structural and functional diversity of ion channels and their role in sensory physiology.

  7. Calcium channel blocker poisoning

    Directory of Open Access Journals (Sweden)

    Miran Brvar

    2005-04-01

    Full Text Available Background: Calcium channel blockers act at L-type calcium channels in cardiac and vascular smooth muscles by preventing calcium influx into cells with resultant decrease in vascular tone and cardiac inotropy, chronotropy and dromotropy. Poisoning with calcium channel blockers results in reduced cardiac output, bradycardia, atrioventricular block, hypotension and shock. The findings of hypotension and bradycardia should suggest poisoning with calcium channel blockers.Conclusions: Treatment includes immediate gastric lavage and whole-bowel irrigation in case of ingestion of sustainedrelease products. All patients should receive an activated charcoal orally. Specific treatment includes calcium, glucagone and insulin, which proved especially useful in shocked patients. Supportive care including the use of catecholamines is not always effective. In the setting of failure of pharmacological therapy transvenous pacing, balloon pump and cardiopulmonary by-pass may be necessary.

  8. TRP channels: an overview

    DEFF Research Database (Denmark)

    Pedersen, Stine Falsig; Owsianik, Grzegorz; Nilius, Bernd

    2005-01-01

    The TRP ("transient receptor potential") family of ion channels now comprises more than 30 cation channels, most of which are permeable for Ca2+, and some also for Mg2+. On the basis of sequence homology, the TRP family can be divided in seven main subfamilies: the TRPC ('Canonical') family......, the TRPV ('Vanilloid') family, the TRPM ('Melastatin') family, the TRPP ('Polycystin') family, the TRPML ('Mucolipin') family, the TRPA ('Ankyrin') family, and the TRPN ('NOMPC') family. The cloning and characterization of members of this cation channel family has exploded during recent years, leading...... to a plethora of data on the roles of TRPs in a variety of tissues and species, including mammals, insects, and yeast. The present review summarizes the most pertinent recent evidence regarding the structural and functional properties of TRP channels, focusing on the regulation and physiology of mammalian TRPs....

  9. Authentication over Noisy Channels

    OpenAIRE

    Lai, Lifeng; Gamal, Hesham El; Poor, H. Vincent

    2008-01-01

    In this work, message authentication over noisy channels is studied. The model developed in this paper is the authentication theory counterpart of Wyner's wiretap channel model. Two types of opponent attacks, namely impersonation attacks and substitution attacks, are investigated for both single message and multiple message authentication scenarios. For each scenario, information theoretic lower and upper bounds on the opponent's success probability are derived. Remarkably, in both scenarios,...

  10. Channelling versus inversion

    DEFF Research Database (Denmark)

    Gale, A.S.; Surlyk, Finn; Anderskouv, Kresten

    2013-01-01

    Evidence from regional stratigraphical patterns in Santonian−Campanian chalk is used to infer the presence of a very broad channel system (5 km across) with a depth of at least 50 m, running NNW−SSE across the eastern Isle of Wight; only the western part of the channel wall and fill is exposed. W......−Campanian chalks in the eastern Isle of Wight, involving penecontemporaneous tectonic inversion of the underlying basement structure, are rejected....

  11. Stream Channel Stability.

    Science.gov (United States)

    1981-04-01

    Cycles of wetting and drying are also t ,v itiue swelling and shrinkage of the soil. S 11ied blocks or peds of soil fabric ,,ks. id downslope soil creep ...hydrographs of water and sediment at the point in question. By feeding the output from the hydrology-transport model into the finite element model...the banks as undercut banks fail. Channel irregularities such as seepage zones, cattle crossings, overbank drainage, buried channels, organic deposits

  12. Channeling and dynamic chaos

    Energy Technology Data Exchange (ETDEWEB)

    Bolotin, IU L; Gonchar, V IU; Truten, V I; Shulga, N F

    1986-01-01

    It is shown that axial channeling of relativistic electrons can give rise to the effect of dynamic chaos which involves essentially chaotic motion of a particle in the channel. The conditions leading to the effect of dynamic chaos and the manifestations of this effect in physical processes associated with the passage of particles through a crystal are examined using a silicon crystal as an example. 7 references.

  13. Course on Ionic Channels

    CERN Document Server

    1986-01-01

    This book is based on a series of lectures for a course on ionic channels held in Santiago, Chile, on November 17-20, 1984. It is intended as a tutorial guide on the properties, function, modulation, and reconstitution of ionic channels, and it should be accessible to graduate students taking their first steps in this field. In the presentation there has been a deliberate emphasis on the spe­ cific methodologies used toward the understanding of the workings and function of channels. Thus, in the first section, we learn to "read" single­ channel records: how to interpret them in the theoretical frame of kinetic models, which information can be extracted from gating currents in re­ lation to the closing and opening processes, and how ion transport through an open channel can be explained in terms of fluctuating energy barriers. The importance of assessing unequivocally the origin and purity of mem­ brane preparations and the use of membrane vesicles and optical tech­ niques in the stUGY of ionic channels a...

  14. Ion channelling in diamond

    International Nuclear Information System (INIS)

    Derry, T.E.

    1978-06-01

    Diamond is one of the most extreme cases from a channelling point of view, having the smallest thermal vibration amplitude and the lowest atomic number of commonly-encountered crystals. These are the two parameters most important for determining channelling behaviour. It is of consiberable interest therefore to see how well the theories explaining and predicting the channeling properties of other substance, succeed with diamond. Natural diamond, although the best available form for these experiments, is rather variable in its physical properties. Part of the project was devoted to considering and solving the problem of obtaining reproducible results representative of the ideal crystal. Channelling studies were performed on several good crystals, using the Rutherford backscattering method. Critical angles for proton channelling were measured for incident energies from 0.6 to 4.5 MeV, in the three most open axes and three most open planes of the diamond structure, and for α-particle channelling at 0.7 and 1.0 MeV (He + ) in the same axes and planes. For 1.0 MeV protons, the crystal temperature was varied from 20 degrees Celsius to 700 degrees Celsius. The results are presented as curves of backscattered yield versus angle in the region of each axis or plane, and summarised in the form of tables and graphs. Generally the critical angles, axial minimum yields, and temperature dependence are well predicted by the accepted theories. The most valuable overall conclusion is that the mean thermal vibration amplitude of the atoms in a crytical determines the critical approach distance to the channel walls at which an ion can remain channelled, even when this distance is much smaller than the Thomas-Fermi screening distance of the atomic potential, as is the case in diamond. A brief study was made of the radiation damage caused by α-particle bombardment, via its effect on the channelling phenomenon. It was possible to hold damage down to negligible levels during the

  15. Optical Communications Channel Combiner

    Science.gov (United States)

    Quirk, Kevin J.; Quirk, Kevin J.; Nguyen, Danh H.; Nguyen, Huy

    2012-01-01

    NASA has identified deep-space optical communications links as an integral part of a unified space communication network in order to provide data rates in excess of 100 Mb/s. The distances and limited power inherent in a deep-space optical downlink necessitate the use of photon-counting detectors and a power-efficient modulation such as pulse position modulation (PPM). For the output of each photodetector, whether from a separate telescope or a portion of the detection area, a communication receiver estimates a log-likelihood ratio for each PPM slot. To realize the full effective aperture of these receivers, their outputs must be combined prior to information decoding. A channel combiner was developed to synchronize the log-likelihood ratio (LLR) sequences of multiple receivers, and then combines these into a single LLR sequence for information decoding. The channel combiner synchronizes the LLR sequences of up to three receivers and then combines these into a single LLR sequence for output. The channel combiner has three channel inputs, each of which takes as input a sequence of four-bit LLRs for each PPM slot in a codeword via a XAUI 10 Gb/s quad optical fiber interface. The cross-correlation between the channels LLR time series are calculated and used to synchronize the sequences prior to combining. The output of the channel combiner is a sequence of four-bit LLRs for each PPM slot in a codeword via a XAUI 10 Gb/s quad optical fiber interface. The unit is controlled through a 1 Gb/s Ethernet UDP/IP interface. A deep-space optical communication link has not yet been demonstrated. This ground-station channel combiner was developed to demonstrate this capability and is unique in its ability to process such a signal.

  16. Channel Choice: A Literature Review

    DEFF Research Database (Denmark)

    Østergaard Madsen, Christian; Kræmmergaard, Pernille

    2015-01-01

    The channel choice branch of e-government studies citizens’ and businesses’ choice of channels for interacting with government, and how government organizations can integrate channels and migrate users towards the most cost-efficient channels. In spite of the valuable contributions offered...

  17. Channel Identification Machines

    Directory of Open Access Journals (Sweden)

    Aurel A. Lazar

    2012-01-01

    Full Text Available We present a formal methodology for identifying a channel in a system consisting of a communication channel in cascade with an asynchronous sampler. The channel is modeled as a multidimensional filter, while models of asynchronous samplers are taken from neuroscience and communications and include integrate-and-fire neurons, asynchronous sigma/delta modulators and general oscillators in cascade with zero-crossing detectors. We devise channel identification algorithms that recover a projection of the filter(s onto a space of input signals loss-free for both scalar and vector-valued test signals. The test signals are modeled as elements of a reproducing kernel Hilbert space (RKHS with a Dirichlet kernel. Under appropriate limiting conditions on the bandwidth and the order of the test signal space, the filter projection converges to the impulse response of the filter. We show that our results hold for a wide class of RKHSs, including the space of finite-energy bandlimited signals. We also extend our channel identification results to noisy circuits.

  18. Channel identification machines.

    Science.gov (United States)

    Lazar, Aurel A; Slutskiy, Yevgeniy B

    2012-01-01

    We present a formal methodology for identifying a channel in a system consisting of a communication channel in cascade with an asynchronous sampler. The channel is modeled as a multidimensional filter, while models of asynchronous samplers are taken from neuroscience and communications and include integrate-and-fire neurons, asynchronous sigma/delta modulators and general oscillators in cascade with zero-crossing detectors. We devise channel identification algorithms that recover a projection of the filter(s) onto a space of input signals loss-free for both scalar and vector-valued test signals. The test signals are modeled as elements of a reproducing kernel Hilbert space (RKHS) with a Dirichlet kernel. Under appropriate limiting conditions on the bandwidth and the order of the test signal space, the filter projection converges to the impulse response of the filter. We show that our results hold for a wide class of RKHSs, including the space of finite-energy bandlimited signals. We also extend our channel identification results to noisy circuits.

  19. Cryogenic microwave channelized receiver

    International Nuclear Information System (INIS)

    Rauscher, C.; Pond, J.M.; Tait, G.B.

    1996-01-01

    The channelized receiver being presented demonstrates the use of high temperature superconductor technology in a microwave system setting where superconductor, microwave-monolithic-integrated-circuit, and hybrid-integrated-circuit components are united in one package and cooled to liquid-nitrogen temperatures. The receiver consists of a superconducting X-band four-channel demultiplexer with 100-MHz-wide channels, four commercial monolithically integrated mixers, and four custom-designed hybrid-circuit detectors containing heterostructure ramp diodes. The composite receiver unit has been integrated into the payload of the second-phase NRL high temperature superconductor space experiment (HTSSE-II). Prior to payload assembly, the response characteristics of the receiver were measured as functions of frequency, temperature, and drive levels. The article describes the circuitry, discusses the key issues related to design and implementation, and summarizes the experimental results

  20. Chaos in quantum channels

    Energy Technology Data Exchange (ETDEWEB)

    Hosur, Pavan; Qi, Xiao-Liang [Department of Physics, Stanford University,476 Lomita Mall, Stanford, California 94305 (United States); Roberts, Daniel A. [Center for Theoretical Physics and Department of Physics, Massachusetts Institute of Technology,77 Massachusetts Ave, Cambridge, Massachusetts 02139 (United States); Yoshida, Beni [Perimeter Institute for Theoretical Physics,31 Caroline Street North, Waterloo, Ontario N2L 2Y5 (Canada); Walter Burke Institute for Theoretical Physics, California Institute of Technology,1200 E California Blvd, Pasadena CA 91125 (United States)

    2016-02-01

    We study chaos and scrambling in unitary channels by considering their entanglement properties as states. Using out-of-time-order correlation functions to diagnose chaos, we characterize the ability of a channel to process quantum information. We show that the generic decay of such correlators implies that any input subsystem must have near vanishing mutual information with almost all partitions of the output. Additionally, we propose the negativity of the tripartite information of the channel as a general diagnostic of scrambling. This measures the delocalization of information and is closely related to the decay of out-of-time-order correlators. We back up our results with numerics in two non-integrable models and analytic results in a perfect tensor network model of chaotic time evolution. These results show that the butterfly effect in quantum systems implies the information-theoretic definition of scrambling.

  1. Distribution Channels Conflict and Management

    OpenAIRE

    Kiran, Dr Vasanth; Majumdar, Dr Mousumi; Kishore, Dr Krishna

    2012-01-01

    Relationships in distribution channels tend to be long-term oriented and members of the channel rely on each other to jointly realize their goals by serving buyers. Despite the channels focus on serving buyers, conflicts often arise between channel members because of each members self-interest. When conflicts arise, the perceptions of a channel member based on normative, rational/instrumental, or emotional reasoning will influence relational norms like trust and commitment that characterize t...

  2. Fuel channel refilling

    International Nuclear Information System (INIS)

    Shoukri, M.; Abdul-Razzak, A.

    1992-11-01

    This report extends the work reported in document INFO-0370 on fuel channel refilling by providing analysis of the refilling tests conducted using the RD-14 and RD-14M test facilities. The analysis focuses on the general thermal-hydraulic characteristics of the facilities following various small and large inlet and outlet header breaks with emergency coolant injection. The two-fluid model thermal-hydraulic computer code CATHENA was tested against results obtained from selected experiments carried out in the two facilities. Conclusions related to the effect of break size, mode of emergency core injection, primary pump operation and parallel channels are presented. (Author) (116 figs., 17 tabs., 53 refs.)

  3. Ion channels in glioblastoma.

    Science.gov (United States)

    Molenaar, Remco J

    2011-01-01

    Glioblastoma is the most common primary brain tumor with the most dismal prognosis. It is characterized by extensive invasion, migration, and angiogenesis. Median survival is only 15 months due to this behavior, rendering focal surgical resection ineffective and adequate radiotherapy impossible. At this moment, several ion channels have been implicated in glioblastoma proliferation, migration, and invasion. This paper summarizes studies on potassium, sodium, chloride, and calcium channels of glioblastoma. It provides an up-to-date overview of the literature that could ultimately lead to new therapeutic targets.

  4. Fuel channel refilling

    International Nuclear Information System (INIS)

    Shoukri, M.; Abdul-Razzak, A.

    1990-04-01

    Analysis of existing data on fuel channel refilling is presented. The analysis focuses on the data obtained using the Stern Laboratories Cold Water Injection Test (CWIT) Facility. The two-fluid model thermal-hydraulics computer code CATHENA is also used to simulate experimental results on fuel channel refilling from both the CWIT and RD-14 facilities. Conclusions related to single and double break tests, including the effect of non-condensible gases, are presented. A set of recommendations is given for further analysis and separate effect experiments. (67 figs., 5 tabs., 24 refs.)

  5. Potassium channels in brain mitochondria.

    Science.gov (United States)

    Bednarczyk, Piotr

    2009-01-01

    Potassium channels are the most widely distributed class of ion channels. These channels are transmembrane proteins known to play important roles in both normal and pathophysiological functions in all cell types. Various potassium channels are recognised as potential therapeutic targets in the treatment of Parkinson's disease, Alzheimer's disease, brain/spinal cord ischaemia and sepsis. In addition to their importance as therapeutic targets, certain potassium channels are known for their beneficial roles in anaesthesia, cardioprotection and neuroprotection. Some types of potassium channels present in the plasma membrane of various cells have been found in the inner mitochondrial membrane as well. Potassium channels have been proposed to regulate mitochondrial membrane potential, respiration, matrix volume and Ca(+) ion homeostasis. It has been proposed that mitochondrial potassium channels mediate ischaemic preconditioning in various tissues. However, the specificity of a pharmacological agents and the mechanisms underlying their effects on ischaemic preconditioning remain controversial. The following potassium channels from various tissues have been identified in the inner mitochondrial membrane: ATP-regulated (mitoK(ATP)) channel, large conductance Ca(2+)-regulated (mitoBK(Ca)) channel, intermediate conductance Ca(2+)-regulated (mitoIK(Ca)) channel, voltage-gated (mitoKv1.3 type) channel, and twin-pore domain (mitoTASK-3) channel. It has been shown that increased potassium flux into brain mitochondria induced by either the mitoK(ATP) channel or mitoBK(Ca) channel affects the beneficial effects on neuronal cell survival under pathological conditions. Recently, differential distribution of mitoBK(Ca) channels has been observed in neuronal mitochondria. These findings may suggest a neuroprotective role for the mitoBK(Ca) channel in specific brain structures. This minireview summarises current data on brain mitochondrial potassium channels and the efforts to identify

  6. MITOCHONDRIAL BKCa CHANNEL

    Directory of Open Access Journals (Sweden)

    Enrique eBalderas

    2015-03-01

    Full Text Available Since its discovery in a glioma cell line 15 years ago, mitochondrial BKCa channel (mitoBKCa has been studied in brain cells and cardiomyocytes sharing general biophysical properties such as high K+ conductance (~300 pS, voltage-dependency and Ca2+-sensitivity. Main advances in deciphering the molecular composition of mitoBKCa have included establishing that it is encoded by the Kcnma1 gene, that a C-terminal splice insert confers mitoBKCa ability to be targeted to cardiac mitochondria, and evidence for its potential coassembly with β subunits. Notoriously, β1 subunit directly interacts with cytochrome c oxidase and mitoBKCa can be modulated by substrates of the respiratory chain. mitoBKCa channel has a central role in protecting the heart from ischemia, where pharmacological activation of the channel impacts the generation of reactive oxygen species and mitochondrial Ca2+ preventing cell death likely by impeding uncontrolled opening of the mitochondrial transition pore. Supporting this view, inhibition of mitoBKCa with Iberiotoxin, enhances cytochrome c release from glioma mitochondria. Many tantalizing questions remain. Some of them are: how is mitoBKCa coupled to the respiratory chain? Does mitoBKCa play non-conduction roles in mitochondria physiology? Which are the functional partners of mitoBKCa? What are the roles of mitoBKCa in other cell types? Answers to these questions are essential to define the impact of mitoBKCa channel in mitochondria biology and disease.

  7. Chemistry in Microfluidic Channels

    Science.gov (United States)

    Chia, Matthew C.; Sweeney, Christina M.; Odom, Teri W.

    2011-01-01

    General chemistry introduces principles such as acid-base chemistry, mixing, and precipitation that are usually demonstrated in bulk solutions. In this laboratory experiment, we describe how chemical reactions can be performed in a microfluidic channel to show advanced concepts such as laminar fluid flow and controlled precipitation. Three sets of…

  8. Workshop on Gas Channels

    Science.gov (United States)

    2013-02-07

    Effect of pressure on gas permeability. In Fish … Different channels or splice variants at different depth.  HRE (hypoxia-response elements): which...proteins unexpectedly have HREs . HIF-1.  Shear stress:  expression of NOS  Are different splice variants used under different conditions?  Size

  9. Quantum communication under channel uncertainty

    International Nuclear Information System (INIS)

    Noetzel, Janis Christian Gregor

    2012-01-01

    This work contains results concerning transmission of entanglement and subspaces as well as generation of entanglement in the limit of arbitrary many uses of compound- and arbitrarily varying quantum channels (CQC, AVQC). In both cases, the channel is described by a set of memoryless channels. Only forward communication between one sender and one receiver is allowed. A code is said to be ''good'' only, if it is ''good'' for every channel out of the set. Both settings describe a scenario, in which sender and receiver have only limited channel knowledge. For different amounts of information about the channel available to sender or receiver, coding theorems are proven for the CQC. For the AVQC, both deterministic and randomised coding schemes are considered. Coding theorems are proven, as well as a quantum analogue of the Ahlswede-dichotomy. The connection to zero-error capacities of stationary memoryless quantum channels is investigated. The notion of symmetrisability is defined and used for both classes of channels.

  10. VAX CAMAC channel

    International Nuclear Information System (INIS)

    Nelson, D.J.; Breidenbach, M.; Granieri, C.D.; Grund, J.E.; Patrick, J.F.; Weaver, L.J.

    1980-10-01

    A new generation CAMAC System has been developed for the Mark II Detector at SLAC's PEP storage ring. This flexible system can efficiently transfer data between a host computer and a very large set of CAMAC data acquisition and control modules. A bipolar microprocessor operates as a Channel interface by supervising the CAMAC system and minimizing the host computer's work. This programmable channel couples the host to a set of System Crates; each System Crate houses Branch Drivers that can directly control a set of crates or communicate over differential parallel highways to Branch Receivers for control of distant crates. A coherent software package integrates the high level programs, system driver level programs, and microcode control of the system

  11. Geysering in boiling channels

    Energy Technology Data Exchange (ETDEWEB)

    Aritomi, Masanori; Takemoto, Takatoshi [Tokyo Institute of Technology, Tokyo (Japan); Chiang, Jing-Hsien [Japan NUS Corp. Ltd., Toyko (Japan)] [and others

    1995-09-01

    A concept of natural circulation BWRs such as the SBWR has been proposed and seems to be promising in that the primary cooling system can be simplified. The authors have been investigating thermo-hydraulic instabilities which may appear during the start-up in natural circulation BWRs. In our previous works, geysering was investigated in parallel boiling channels for both natural and forced circulations, and its driving mechanism and the effect of system pressure on geysering occurrence were made clear. In this paper, geysering is investigated in a vertical column and a U-shaped vertical column heated in the lower parts. It is clarified from the results that the occurrence mechanism of geysering and the dependence of system pressure on geysering occurrence coincide between parallel boiling channels in circulation systems and vertical columns in non-circulation systems.

  12. Coolant channel module CCM

    International Nuclear Information System (INIS)

    Hoeld, Alois

    2007-01-01

    A complete and detailed description of the theoretical background of an '(1D) thermal-hydraulic drift-flux based mixture-fluid' coolant channel model and its resulting module CCM will be presented. The objective of this module is to simulate as universally as possible the steady state and transient behaviour of the key characteristic parameters of a single- or two-phase fluid flowing within any type of heated or non-heated coolant channel. Due to the possibility that different flow regimes can appear along any channel, such a 'basic (BC)' 1D channel is assumed to be subdivided into a number of corresponding sub-channels (SC-s). Each SC can belong to only two types of flow regime, an SC with just a single-phase fluid, containing exclusively either sub-cooled water or superheated steam, or an SC with a two-phase mixture flow. After an appropriate nodalisation of such a BC (and therefore also its SC-s) a 'modified finite volume method' has been applied for the spatial discretisation of the partial differential equations (PDE-s) which represent the basic conservation equations of thermal-hydraulics. Special attention had to be given to the possibility of variable SC entrance or outlet positions (which describe boiling boundaries or mixture levels) and thus the fact that an SC can even disappear or be created anew. The procedure yields for each SC type (and thus the entire BC), a set of non-linear ordinary 1st order differential equations (ODE-s). To link the resulting mean nodal with the nodal boundary function values, both of which are present in the discretised differential equations, a special quadratic polygon approximation procedure (PAX) had to be constructed. Together with the very thoroughly tested packages for drift-flux, heat transfer and single- and two-phase friction factors this procedure represents the central part of the here presented 'Separate-Region' approach, a theoretical model which provides the basis to the very effective working code package CCM

  13. Tourism distribution channels

    OpenAIRE

    Camilleri, Mark Anthony

    2017-01-01

    The distribution channels link the customers with the businesses. For many years, the tourism businesses may have distributed their products and services through intermediaries. However, the latest advances in technology have brought significant changes in this regard. More individuals and corporate customers are increasingly benefiting of ubiquitous technologies, including digital media. The development of mobile devices and their applications, are offering a wide range of possibilities to t...

  14. Athermal channeled spectropolarimeter

    Science.gov (United States)

    Jones, Julia Craven

    2015-12-08

    A temperature insensitive (athermal) channeled spectropolarimeter (CSP) is described. The athermal CSP includes a crystal retarder formed of a biaxial crystal. The crystal retarder has three crystal axes, wherein each axis has its own distinct index of refraction. The axes are oriented in a particular manner, causing an amplitude modulating carrier frequency induced by the crystal retarder to be thermally invariant. Accordingly, a calibration beam technique can be used over a relatively wide range of ambient temperatures, with a common calibration data set.

  15. Nuclear reactor coolant channels

    International Nuclear Information System (INIS)

    Macbeth, R.V.

    1978-01-01

    A nuclear reactor coolant channel is described that is suitable for sub-cooled reactors as in pressurised water reactors as well as for bulk boiling, as in boiling water reactors and steam generating nuclear reactors. The arrangement aims to improve heat transfer between the fuel elements and the coolant. Full constructional details are given. See also other similar patents by the author. (U.K.)

  16. The M2 Channel

    DEFF Research Database (Denmark)

    Santner, Paul

    Drug resistance of Influenza A against antivirals is an increasing problem. No effective Influenza A drugs targeting the crucial viral protein, the proton transporter M2 are available anymore due to widespread resistance. Thanks to research efforts elucidating M2 protein structure, function and i...... resistance escape routes from drug inhibition. We thereby were hopefully able to provide a platform for the large-scale evaluation of M2 channel activity, inhibitors and resistance....

  17. Aquaglyceroporins: generalized metalloid channels

    Science.gov (United States)

    Mukhopadhyay, Rita; Bhattacharjee, Hiranmoy; Rosen, Barry P.

    2014-01-01

    Background: Aquaporins (AQPs), members of a superfamily of transmembrane channel proteins, are ubiquitous in all domains of life. They fall into a number of branches that can be functionally categorized into two major sub-groups: i) orthodox aquaporins, which are water-specific channels, and ii) aquaglyceroporins, which allow the transport of water, non-polar solutes, such as urea or glycerol, the reactive oxygen species hydrogen peroxide, and gases such as ammonia, carbon dioxide and nitric oxide and, as described in this review, metalloids. Scope of Review: This review summarizes the key findings that AQP channels conduct bidirectional movement of metalloids into and out of cells. Major Conclusions: As(OH)3 and Sb(OH)3 behave as inorganic molecular mimics of glycerol, a property that allows their passage through AQP channels. Plant AQPs also allow the passage of boron and silicon as their hydroxyacids, boric acid (B(OH)3) and orthosilicic acid (Si(OH)4), respectively. Genetic analysis suggests that germanic acid (GeO2) is also a substrate. While As(III), Sb(III) and Ge(IV) are toxic metalloids, borate (B(III)) and silicate (Si(IV)) are essential elements in higher plants. General Significance: The uptake of environmental metalloids by aquaporins provides an understanding of (i) how toxic elements such as arsenic enter the food chain; (ii) the delivery of arsenic and antimony containing drugs in the treatment of certain forms of leukemia and chemotherapy of diseases caused by pathogenic protozoa; and (iii) the possibility that food plants such as rice could be made safer by genetically modifying them to exclude arsenic while still accumulating boron and silicon. PMID:24291688

  18. Matching Dyadic Distributions to Channels

    OpenAIRE

    Böcherer, Georg; Mathar, Rudolf

    2010-01-01

    Many communication channels with discrete input have non-uniform capacity achieving probability mass functions (PMF). By parsing a stream of independent and equiprobable bits according to a full prefix-free code, a modu-lator can generate dyadic PMFs at the channel input. In this work, we show that for discrete memoryless channels and for memoryless discrete noiseless channels, searching for good dyadic input PMFs is equivalent to minimizing the Kullback-Leibler distance between a dyadic PMF ...

  19. Radar channel balancing with commutation

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2014-02-01

    When multiple channels are employed in a pulse-Doppler radar, achieving and maintaining balance between the channels is problematic. In some circumstances the channels may be commutated to achieve adequate balance. Commutation is the switching, trading, toggling, or multiplexing of the channels between signal paths. Commutation allows modulating the imbalance energy away from the balanced energy in Doppler, where it can be mitigated with filtering.

  20. Microstructural information from channeling measurements

    International Nuclear Information System (INIS)

    Quere, Y.

    1984-09-01

    Channeling is sensitive to nearly all structural changes in solids. One briefly recalls how particles are dechanneled by lattice defects and describes the main applications of channeling to materials science: detection of radiation damage, location of impurity atoms, precipitations in alloys... Channeling being a phenomenon characteristic of perfect crystals, any type of lattice imperfection (phonons, crystal defects, precipitation etc.) is expected to produce dechanneling. Consequently channeling and its opposite, dechanneling, have both been used to study structure and structural changes of materials

  1. Ion channeling revisited

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, Barney Lee [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Corona, Aldo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nguyen, Anh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    A MS Excel program has been written that calculates accidental, or unintentional, ion channeling in cubic bcc, fcc and diamond lattice crystals or polycrystalline materials. This becomes an important issue when simulating the creation by energetic neutrons of point displacement damage and extended defects using beams of ions. All of the tables and graphs in the three Ion Beam Analysis Handbooks that previously had to be manually looked up and read from were programed into Excel in handy lookup tables, or parameterized, for the case of the graphs, using rather simple exponential functions with different powers of the argument. The program then offers an extremely convenient way to calculate axial and planar half-angles and minimum yield or dechanneling probabilities, effects on half-angles of amorphous overlayers, accidental channeling probabilities for randomly oriented crystals or crystallites, and finally a way to automatically generate stereographic projections of axial and planar channeling half-angles. The program can generate these projections and calculate these probabilities for axes and [hkl] planes up to (555).

  2. The alpha channeling effect

    Science.gov (United States)

    Fisch, N. J.

    2015-12-01

    Alpha particles born through fusion reactions in a tokamak reactor tend to slow down on electrons, but that could take up to hundreds of milliseconds. Before that happens, the energy in these alpha particles can destabilize on collisionless timescales toroidal Alfven modes and other waves, in a way deleterious to energy confinement. However, it has been speculated that this energy might be instead be channeled into useful energy, so as to heat fuel ions or to drive current. Such a channeling needs to be catalyzed by waves Waves can produce diffusion in energy of the alpha particles in a way that is strictly coupled to diffusion in space. If these diffusion paths in energy-position space point from high energy in the center to low energy on the periphery, then alpha particles will be cooled while forced to the periphery. The energy from the alpha particles is absorbed by the wave. The amplified wave can then heat ions or drive current. This process or paradigm for extracting alpha particle energy collisionlessly has been called alpha channeling. While the effect is speculative, the upside potential for economical fusion is immense. The paradigm also operates more generally in other contexts of magnetically confined plasma.

  3. TRP channels in kidney disease.

    NARCIS (Netherlands)

    Hsu, Y.J.; Hoenderop, J.G.J.; Bindels, R.J.M.

    2007-01-01

    Mammalian TRP channel proteins form six-transmembrane cation-permeable channels that may be grouped into six subfamilies on the basis of amino acid sequence homology (TRPC, TRPV, TRPM, TRPA, TRPP, and TRPML). Recent studies of TRP channels indicate that they are involved in numerous fundamental cell

  4. Parallel inter channel interaction mechanisms

    International Nuclear Information System (INIS)

    Jovic, V.; Afgan, N.; Jovic, L.

    1995-01-01

    Parallel channels interactions are examined. For experimental researches of nonstationary regimes flow in three parallel vertical channels results of phenomenon analysis and mechanisms of parallel channel interaction for adiabatic condition of one-phase fluid and two-phase mixture flow are shown. (author)

  5. Voltage-Gated Calcium Channels

    Science.gov (United States)

    Zamponi, Gerald Werner

    Voltage Gated Calcium Channels is the first comprehensive book in the calcium channel field, encompassing over thirty years of progress towards our understanding of calcium channel structure, function, regulation, physiology, pharmacology, and genetics. This book balances contributions from many of the leading authorities in the calcium channel field with fresh perspectives from risings stars in the area, taking into account the most recent literature and concepts. This is the only all-encompassing calcium channel book currently available, and is an essential resource for academic researchers at all levels in the areas neuroscience, biophysics, and cardiovascular sciences, as well as to researchers in the drug discovery area.

  6. Beyond the Manual Channel

    DEFF Research Database (Denmark)

    , the main focus there is on spoken languages in their written and spoken forms. This series of workshops, however, offers a forum for researchers focussing on sign languages. For the fourth time, the workshop had sign language corpora as its main topic. This time, the focus was on any aspect beyond...... the manual channel. Not surprisingly, most papers deal with non-manuals on the face. Once again, the papers at this workshop clearly identify the potentials of even closer cooperation between sign linguists and sign language engineers, and we think it is events like this that contribute a lot to a better...

  7. Ion Channels in Leukocytes

    Science.gov (United States)

    1991-07-01

    muscle k142), heart muscle (80), bo- are released. In recent years much has been learned vine pulmonar arter endothelial cells (251), and rat about the...b3 Zn or cytes from cystic fibrosis patients lack a Cl current that Ni (1 mM)-added to the cytoplasmic side of the mem- can be acti% ated b3 the...that at37’C hu- to be defectiv.- in cystic fibrosis (55, 277), and Chen et al. man T-cell CiL channels are active at rest, implies that (25) have shown

  8. A Micromechanical RF Channelizer

    Science.gov (United States)

    Akgul, Mehmet

    The power consumption of a radio generally goes as the number and strength of the RF signals it must process. In particular, a radio receiver would consume much less power if the signal presented to its electronics contained only the desired signal in a tiny percent bandwidth frequency channel, rather than the typical mix of signals containing unwanted energy outside the desired channel. Unfortunately, a lack of filters capable of selecting single channel bandwidths at RF forces the front-ends of contemporary receivers to accept unwanted signals, and thus, to operate with sub-optimal efficiency. This dissertation focuses on the degree to which capacitive-gap transduced micromechanical resonators can achieve the aforementioned RF channel-selecting filters. It aims to first show theoretically that with appropriate scaling capacitive-gap transducers are strong enough to meet the needed coupling requirements; and second, to fully detail an architecture and design procedure needed to realize said filters. Finally, this dissertation provides an actual experimentally demonstrated RF channel-select filter designed using the developed procedures and confirming theoretical predictions. Specifically, this dissertation introduces four methods that make possible the design and fabrication of RF channel-select filters. The first of these introduces a small-signal equivalent circuit for parallel-plate capacitive-gap transduced micromechanical resonators that employs negative capacitance to model the dependence of resonance frequency on electrical stiffness in a way that facilitates the analysis of micromechanical circuits loaded with arbitrary electrical impedances. The new circuit model not only correctly predicts the dependence of electrical stiffness on the impedances loading the input and output electrodes of parallel-plate capacitive-gap transduced micromechanical device, but does so in a visually intuitive way that identifies current drive as most appropriate for

  9. TRPV6 channels.

    Science.gov (United States)

    Fecher-Trost, Claudia; Weissgerber, Petra; Wissenbach, Ulrich

    2014-01-01

    TRPV6 (former synonyms ECAC2, CaT1, CaT-like) displays several specific features which makes it unique among the members of the mammalian Trp gene family (1) TRPV6 (and its closest relative, TRPV5) are the only highly Ca(2+)-selective channels of the entire TRP superfamily (Peng et al. 1999; Wissenbach et al. 2001; Voets et al. 2004). (2) Translation of Trpv6 initiates at a non-AUG codon, at ACG, located upstream of the annotated AUG, which is not used for initiation (Fecher-Trost et al. 2013). The ACG codon is nevertheless decoded by methionine. Not only a very rare event in eukaryotic biology, the full-length TRPV6 protein existing in vivo comprises an amino terminus extended by 40 amino acid residues compared to the annotated truncated TRPV6 protein which has been used in most studies on TRPV6 channel activity so far. (In the following numbering occurs according to this full-length protein, with the numbers of the so far annotated truncated protein in brackets). (3) Only in humans a coupled polymorphism of Trpv6 exists causing three amino acid exchanges and resulting in an ancestral Trpv6 haplotype and a so-called derived Trpv6 haplotype (Wissenbach et al. 2001). The ancestral allele encodes the amino acid residues C197(157), M418(378) and M721(681) and the derived alleles R197(157), V418(378) and T721(681). The ancestral haplotype is found in all species, the derived Trpv6 haplotype has only been identified in humans, and its frequency increases with the distance to the African continent. Apparently the Trpv6 gene has been a strong target for selection in humans, and its derived variant is one of the few examples showing consistently differences to the orthologues genes of other primates (Akey et al. 2004, 2006; Stajich and Hahn 2005; Hughes et al. 2008). (4) The Trpv6 gene expression is significantly upregulated in several human malignancies including the most common cancers, prostate and breast cancer (Wissenbach et al. 2001; Zhuang et al. 2002; Fixemer et al

  10. Mimicking multi-channel scattering with single-channel approaches

    OpenAIRE

    Grishkevich, Sergey; Schneider, Philipp-Immanuel; Vanne, Yulian V.; Saenz, Alejandro

    2009-01-01

    The collision of two atoms is an intrinsic multi-channel (MC) problem as becomes especially obvious in the presence of Feshbach resonances. Due to its complexity, however, single-channel (SC) approximations, which reproduce the long-range behavior of the open channel, are often applied in calculations. In this work the complete MC problem is solved numerically for the magnetic Feshbach resonances (MFRs) in collisions between generic ultracold 6Li and 87Rb atoms in the ground state and in the ...

  11. Multiplicative properties of quantum channels

    Science.gov (United States)

    Rahaman, Mizanur

    2017-08-01

    In this paper, we study the multiplicative behaviour of quantum channels, mathematically described by trace preserving, completely positive maps on matrix algebras. It turns out that the multiplicative domain of a unital quantum channel has a close connection to its spectral properties. A structure theorem (theorem 2.5), which reveals the automorphic property of an arbitrary unital quantum channel on a subalgebra, is presented. Various classes of quantum channels (irreducible, primitive, etc) are then analysed in terms of this stabilising subalgebra. The notion of the multiplicative index of a unital quantum channel is introduced, which measures the number of times a unital channel needs to be composed with itself for the multiplicative algebra to stabilise. We show that the maps that have trivial multiplicative domains are dense in completely bounded norm topology in the set of all unital completely positive maps. Some applications in quantum information theory are discussed.

  12. Manifestações destrutivas da córnea e esclera associadas a doenças do tecido conectivo: relato de 9 casos Corneal and scleral destructive involvement associated with connective tissue disease: report of 9 cases

    Directory of Open Access Journals (Sweden)

    Namir Clementino Santos

    2004-08-01

    apropriado da doença de base.PURPOSE: To study the clinical features, diagnosis, treatment, and outcome of nine patients with corneal and scleral involvement associated to connective tissue disease. METHODS: Description of anterior segment abnormalities observed in nine patients with connective tissue disease, five of them previously diagnosed and four with the ocular involvement being the first manifestation of the disease. All patients were evaluated at the Corneal and External Diseases outpatient clinic of the Federal University of São Paulo - Escola Paulista de Medicina (UNIFESP-EPM between July/1999 to December/2000 and were submitted to a complete ophthalmologic examination, clinical evaluation and laboratory investigation. Clinical or surgical treatment was indicated according to the ocular disease evolution. RESULTS: The clinical diagnoses of the patients with anterior segment inflammatory disease were rheumatoid arthritis in seven patients (77.8%, systemic sclerosis and Wegener´s granulomatosis in each of the remaining patients (22.2%. The most frequent ocular manifestation was scleritis (66.6%, followed by peripheral ulcerative keratitis (55.5% and dry eye syndrome (44.4%. Eighty-nine percent (89% of the patients required immunosuppressive therapy to control the ocular inflammatory disease. Remission of the ocular symptoms were observed after 3 months of the beginning of imunossupressive therapy on average. In 55.5% of the patients a surgical approach (conjunctival resection, application of cyanoacrylate tissue adhesive, penetrating keratoplasty and scleral patch graft was necessary. CONCLUSION: The finding of corneal and scleral involvement associated with connective tissue disease is a sign of the disease activity and usually requires imunossupressive therapy. The ophthalmologists should be aware of these conditions in order to early diagnose and apply the appropriate treatment.

  13. Upgrading a marketing channels role

    Directory of Open Access Journals (Sweden)

    Tišma-Borota Ankica

    2002-01-01

    Full Text Available As one of the marketing mix instruments, marketing channels were usually behind other instruments (product, price and promotion. Many companies regarded marketing channels as something that was 'left' after more important strategies of price, product and promotion were created. In recent past, things have changed and marketing channels became more interesting for research. This change came as a result of change in global market functioning especially in competitive advantage, distributors' strength and increasing technology.

  14. Single-channel kinetics of BK (Slo1 channels

    Directory of Open Access Journals (Sweden)

    Yanyan eGeng

    2015-01-01

    Full Text Available Single-channel kinetics has proven a powerful tool to reveal information about the gating mechanisms that control the opening and closing of ion channels. This introductory review focuses on the gating of large conductance Ca2+- and voltage-activated K+ (BK or Slo1 channels at the single-channel level. It starts with single-channel current records and progresses to presentation and analysis of single-channel data and the development of gating mechanisms in terms of discrete state Markov (DSM models. The DSM models are formulated in terms of the tetrameric modular structure of BK channels, consisting of a central transmembrane pore-gate domain (PGD attached to four surrounding transmembrane voltage sensing domains (VSD and a large intracellular cytosolic domain (CTD, also referred to as the gating ring. The modular structure and data analysis shows that the Ca2+ and voltage dependent gating considered separately can each be approximated by 10-state two-tiered models with 5 closed states on the upper tier and 5 open states on the lower tier. The modular structure and joint Ca2+ and voltage dependent gating are consistent with a 50 state two-tiered model with 25 closed states on the upper tier and 25 open states on the lower tier. Adding an additional tier of brief closed (flicker states to the 10-state or 50-state models improved the description of the gating. For fixed experimental conditions a channel would gate in only a subset of the potential number of states. The detected number of states and the correlations between adjacent interval durations are consistent with the tiered models. The examined models can account for the single-channel kinetics and the bursting behavior of gating. Ca2+ and voltage activate BK channels by predominantly increasing the effective opening rate of the channel with a smaller decrease in the effective closing rate. Ca2+ and depolarization thus activate by mainly destabilizing the closed states.

  15. UMTS Common Channel Sensitivity Analysis

    DEFF Research Database (Denmark)

    Pratas, Nuno; Rodrigues, António; Santos, Frederico

    2006-01-01

    and as such it is necessary that both channels be available across the cell radius. This requirement makes the choice of the transmission parameters a fundamental one. This paper presents a sensitivity analysis regarding the transmission parameters of two UMTS common channels: RACH and FACH. Optimization of these channels...... is performed and values for the key transmission parameters in both common channels are obtained. On RACH these parameters are the message to preamble offset, the initial SIR target and the preamble power step while on FACH it is the transmission power offset....

  16. Demystifying Mechanosensitive Piezo Ion Channels.

    Science.gov (United States)

    Xu, X Z Shawn

    2016-06-01

    Mechanosensitive channels mediate touch, hearing, proprioception, and blood pressure regulation. Piezo proteins, including Piezo1 and Piezo2, represent a new class of mechanosensitive channels that have been reported to play key roles in most, if not all, of these modalities. The structural architecture and molecular mechanisms by which Piezos act as mechanosensitive channels, however, remain mysterious. Two new studies have now provided critical insights into the atomic structure and molecular basis of the ion permeation and mechano-gating properties of the Piezo1 channel.

  17. Defect Distributions in Channeling Experiments

    DEFF Research Database (Denmark)

    Andersen, Hans Henrik; Sigmund, P.

    1965-01-01

    A simple collision model allows to calculate energy losses of perfectly channeled particles. The maximum energy loss is related in a simple way to the displacement energy of lattice atoms perpendicular to the channel. From that, one obtains rather definite predictions on the possibility...... of radiation damage by channeled particles. As an application, one gets a necessary criterion for the occurence of super tails in channeling experiments. The theory involves some assumptions on the behaviour of Born-Mayer potentials which are verified by comparison to experimental displacement energies....

  18. Preservation of meandering river channels in uniformly aggrading channel belts

    NARCIS (Netherlands)

    Lageweg, W.I. van de; Schuurman, F.; Cohen, K.M.; Dijk, W.M. van; Shimizu, Y.; Kleinhans, M.G.

    2016-01-01

    Channel belt deposits from meandering river systems commonly display an internal architecture of stacked depositional features with scoured basal contacts due to channel and bedform migration across a range of scales. Recognition and correct interpretation of these bounding surfaces is essential to

  19. MONETARY TRANSMISSION CHANNELS IN ROMANIA – THE CREDIT CHANNEL

    Directory of Open Access Journals (Sweden)

    Magdalena RĂDULESCU

    2009-12-01

    Full Text Available The theoretical – intuitive analysis applied to the segment of monetary transmission evidences the fact that forming the traditional monetary impulses transmission channels are in a starting phase due to the long financial non – intermediary process which Romanian economy had known. In these conditions, the exchange rate channel, and also NBR currency purchases was, for a long time, an important way through which monetary authorities actions influenced macro economical behaviors. But starting with 2000, it is observed a credit channel reactivation and, especially, interest rate channel. Anyhow, the credit channel continues to be undermined by the existence of liquidity surplus within the system, by the phenomena of substitution of national currency credit with currency credits, and also moral hazardous displays. Albeit some of these phenomena also affect the interest rate channel, its role in sending monetary policy impulses is in a continuous progress. Apparently, it acts by way of nominal interest rates, their real level seeming less relevant. Once with remaking the two traditional channels, the companies and households balance is configured and consolidated, which shall potentate in the future the efficiency of the monetary policy. This paper analyses the credit channel in Romania, through an unrestricted VAR analysis.. It shows the responses of exchange rate, inflation rate, GDP, interest rate, imports and exports to a shock on non-governmental credit

  20. ZnO-channel thin-film transistors: Channel mobility

    International Nuclear Information System (INIS)

    Hoffman, R.L.

    2004-01-01

    ZnO-channel thin-film transistor (TFT) test structures are fabricated using a bottom-gate structure on thermally oxidized Si; ZnO is deposited via RF sputtering from an oxide target, with an unheated substrate. Electrical characteristics are evaluated, with particular attention given to the extraction and interpretation of transistor channel mobility. ZnO-channel TFT mobility exhibits severe deviation from that assumed by ideal TFT models; mobility extraction methodology must accordingly be recast so as to provide useful insight into device operation. Two mobility metrics, μ avg and μ inc , are developed and proposed as relevant tools in the characterization of nonideal TFTs. These mobility metrics are employed to characterize the ZnO-channel TFTs reported herein; values for μ inc as high as 25 cm2/V s are measured, comprising a substantial increase in ZnO-channel TFT mobility as compared to previously reported performance for such devices

  1. An improved channel assessment scheme

    KAUST Repository

    Bader, Ahmed

    2014-01-01

    A source node in a multihop network determines whether to transmit in a channel based on whether the channel is occupied by a packet transmission with a large number of relays; whether the source node is in the data tones back-off zone; and the source node is in the busy tone back-off zone.

  2. Quantum communication under channel uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Noetzel, Janis Christian Gregor

    2012-09-06

    This work contains results concerning transmission of entanglement and subspaces as well as generation of entanglement in the limit of arbitrary many uses of compound- and arbitrarily varying quantum channels (CQC, AVQC). In both cases, the channel is described by a set of memoryless channels. Only forward communication between one sender and one receiver is allowed. A code is said to be ''good'' only, if it is ''good'' for every channel out of the set. Both settings describe a scenario, in which sender and receiver have only limited channel knowledge. For different amounts of information about the channel available to sender or receiver, coding theorems are proven for the CQC. For the AVQC, both deterministic and randomised coding schemes are considered. Coding theorems are proven, as well as a quantum analogue of the Ahlswede-dichotomy. The connection to zero-error capacities of stationary memoryless quantum channels is investigated. The notion of symmetrisability is defined and used for both classes of channels.

  3. Perceived quality of channel zapping

    NARCIS (Netherlands)

    Kooij, R.E.; Ahmed, K.; Brunnström, K.

    2006-01-01

    The end user experience of service quality is critical to the success of a service provider's IPTV deployment program. A key element involved in validating IPTV quality of experience (QoE) is how quickly and reliably users can change TV channels, often referred to as channel zapping. Currently there

  4. Channel's Concurrence and Quantum Teleportation

    Institute of Scientific and Technical Information of China (English)

    LING Yin-Sheng

    2005-01-01

    Concurrence can measure the entanglement property of a system. If the channel is a pure state, positive concurrence state can afford the good performance in the teleportation process. If the channel ia a mixed state, positive concurrence state cannot assure the good performance in the teleportation. The conditions of the positive concurrence and the quantum teleportation in the Heisenberg spin ring is derived.

  5. An improved channel assessment scheme

    KAUST Repository

    Bader, Ahmed

    2014-05-01

    A source node in a multihop network determines whether to transmit in a channel based on whether the channel is occupied by a packet transmission with a large number of relays; whether the source node is in the data tones back-off zone; and the source node is in the busy tone back-off zone.

  6. Decreasing vortex flux in channels

    International Nuclear Information System (INIS)

    Migaj, V.K.; Nosova, I.S.

    1979-01-01

    A new method for reducing vortex flow losses in power plant channels is suggested. The method is based on vortex splitting in vortex flow areas with transverse barriers placed on the channel walls. The upper barrier ends are at the level of the upper boundary of the vortex area and don't protrude to the active flow beyond this boundary. The effectiveness of the method suggested is illustrated taking as an example the investigation of square and flat channels with abrupt widening in one plane, diffusers with widening in one plane, or a rectangualr bend. It is shown that splitting the vortex areas with transverse barriers in the channels results in reduction of hydraulic losses by 10-25%. The above method is characteristic of an extreme simplicity, its application doesn't require changes in the channel shape nor installation of any devices in the flow

  7. Channel box dimension measuring method

    International Nuclear Information System (INIS)

    Oshima, Hirotake; Jo, Hiroto.

    1994-01-01

    The present invention provides a method for measuring the entire length of a channel box of a fuel assembly of a BWR type reactor. Namely, four sensors are used as one set that generate ultrasonic waves from oblique upper portion, oblique lower portion, upper portion and lower portion of the channel box respectively. The distances between the four sensors and each of the portions of the channel box are measured respectively for both of a reference member and a member to be measured. The entire length of the channel box is measured by calculating the measured values and the angles of the obliquely disposed sensors according to a predetermined formula. According to the method of the present invention, the inclination of the channel box to be measured can be corrected. In addition, accuracy of the measurement is improved and the measuring time is saved as well as the measuring device and operation can be simplified. (I.S.)

  8. Marketing channels and competitive advantage

    Directory of Open Access Journals (Sweden)

    Jovičić Dragoljub

    2005-01-01

    Full Text Available Issue that can already be seen and will be very clear in the future is that the central problem in the market of tube caps will not be the product or the price or promotion, but marketing channels. Therefore, the competitive advantage will most probably be built on marketing channels and not the production - as it has been so far, so, the questions of choice functioning and modification of marketing channels, as well as selection of the most appropriate members of channels will become more and more important. Accordingly, it may freely be said that the choice, i.e. the movement of marketing channels represents one of the strategic decisions which has to be made by a company management and which will subsequently very significantly influence the functioning and efficacy of not only the system of distribution, but also the entire business transactions.

  9. Methods of channeling simulation

    International Nuclear Information System (INIS)

    Barrett, J.H.

    1989-06-01

    Many computer simulation programs have been used to interpret experiments almost since the first channeling measurements were made. Certain aspects of these programs are important in how accurately they simulate ions in crystals; among these are the manner in which the structure of the crystal is incorporated, how any quantity of interest is computed, what ion-atom potential is used, how deflections are computed from the potential, incorporation of thermal vibrations of the lattice atoms, correlations of thermal vibrations, and form of stopping power. Other aspects of the programs are included to improve the speed; among these are table lookup, importance sampling, and the multiparameter method. It is desirable for programs to facilitate incorporation of special features of interest in special situations; examples are relaxations and enhanced vibrations of surface atoms, easy substitution of an alternate potential for comparison, change of row directions from layer to layer in strained-layer lattices, and different vibration amplitudes for substitutional solute or impurity atoms. Ways of implementing all of these aspects and features and the consequences of them will be discussed. 30 refs., 3 figs

  10. Based on Channel Characteristics

    Directory of Open Access Journals (Sweden)

    Zhuo Hao

    2013-01-01

    Full Text Available A number of key agreement schemes based on wireless channel characteristics have been proposed recently. However, previous key agreement schemes require that two nodes which need to agree on a key are within the communication range of each other. Hence, they are not suitable for multihop wireless networks, in which nodes do not always have direct connections with each other. In this paper, we first propose a basic multihop key agreement scheme for wireless ad hoc networks. The proposed basic scheme is resistant to external eavesdroppers. Nevertheless, this basic scheme is not secure when there exist internal eavesdroppers or Man-in-the-Middle (MITM adversaries. In order to cope with these adversaries, we propose an improved multihop key agreement scheme. We show that the improved scheme is secure against internal eavesdroppers and MITM adversaries in a single path. Both performance analysis and simulation results demonstrate that the improved scheme is efficient. Consequently, the improved key agreement scheme is suitable for multihop wireless ad hoc networks.

  11. Information geometry of Gaussian channels

    International Nuclear Information System (INIS)

    Monras, Alex; Illuminati, Fabrizio

    2010-01-01

    We define a local Riemannian metric tensor in the manifold of Gaussian channels and the distance that it induces. We adopt an information-geometric approach and define a metric derived from the Bures-Fisher metric for quantum states. The resulting metric inherits several desirable properties from the Bures-Fisher metric and is operationally motivated by distinguishability considerations: It serves as an upper bound to the attainable quantum Fisher information for the channel parameters using Gaussian states, under generic constraints on the physically available resources. Our approach naturally includes the use of entangled Gaussian probe states. We prove that the metric enjoys some desirable properties like stability and covariance. As a by-product, we also obtain some general results in Gaussian channel estimation that are the continuous-variable analogs of previously known results in finite dimensions. We prove that optimal probe states are always pure and bounded in the number of ancillary modes, even in the presence of constraints on the reduced state input in the channel. This has experimental and computational implications. It limits the complexity of optimal experimental setups for channel estimation and reduces the computational requirements for the evaluation of the metric: Indeed, we construct a converging algorithm for its computation. We provide explicit formulas for computing the multiparametric quantum Fisher information for dissipative channels probed with arbitrary Gaussian states and provide the optimal observables for the estimation of the channel parameters (e.g., bath couplings, squeezing, and temperature).

  12. Channel Simulation in Quantum Metrology

    Directory of Open Access Journals (Sweden)

    Laurenza Riccardo

    2018-04-01

    Full Text Available In this review we discuss how channel simulation can be used to simplify the most general protocols of quantum parameter estimation, where unlimited entanglement and adaptive joint operations may be employed. Whenever the unknown parameter encoded in a quantum channel is completely transferred in an environmental program state simulating the channel, the optimal adaptive estimation cannot beat the standard quantum limit. In this setting, we elucidate the crucial role of quantum teleportation as a primitive operation which allows one to completely reduce adaptive protocols over suitable teleportation-covariant channels and derive matching upper and lower bounds for parameter estimation. For these channels,wemay express the quantum Cramér Rao bound directly in terms of their Choi matrices. Our review considers both discrete- and continuous-variable systems, also presenting some new results for bosonic Gaussian channels using an alternative sub-optimal simulation. It is an open problem to design simulations for quantum channels that achieve the Heisenberg limit.

  13. Skeletal Muscle Na+ Channel Disorders

    Directory of Open Access Journals (Sweden)

    Dina eSimkin

    2011-10-01

    Full Text Available Five inherited human disorders affecting skeletal muscle contraction have been traced to mutations in the gene encoding the voltage-gated sodium channel Nav1.4. The main symptoms of these disorders are myotonia or periodic paralysis caused by changes in skeletal muscle fiber excitability. Symptoms of these disorders vary from mild or latent disease to incapacitating or even death in severe cases. As new human sodium channel mutations corresponding to disease states become discovered, the importance of understanding the role of the sodium channel in skeletal muscle function and disease state grows.

  14. [Effect of tranilast on wound healing and administration time on scar hyperplasia of deep partial-thickness burn in mice].

    Science.gov (United States)

    Hu, Zhenzhen; Chen, Bin; Li, Yang; Jiang, Wei; Wen, Lihong; Ji, Fukang; Yang, Xiao; Wang, Jinhuang; Liu, Dalie

    2017-04-01

    To investigate the effect of tranilast on wound healing and the mechanism of inhibiting scar hyperplasia in mice, and to study the relationship between the inhibiting ability of tranilast on scar hyperplasia and administration time. Sixty-six Kunming mice were selected to build deep II degree burn model, and were randomly divided into the control group (18 mice), the early intervention group (18 mice), the medium intervention group (18 mice), and the late intervention group (12 mice). The mice in the early intervention group, the medium-term intervention group, and the late intervention group were given tranilast 200 mg/(kg·d) by gastrogavage at immediate, 7 days, and 14 days after burn respectively, and the mice in the control group were managed with same amount of normal saline every day. The wound healing was observed regularly. At 14, 28, and 42 days in the early and medium intervention groups and at 28 and 42 days in the late intervention group, fresh tissues were taken from 6 mice to observe the shape of mast cells by toluidine blue staining, collagen content by Masson staining; the collagen type I and collagen type III content were measured to calculate the I/III collagen content ratio by immunohistochemistry method, the contents of transforming growth factor β 1 (TGF-β 1 ) and histamine were detected by ELISA; and the ultrastructure of fibroblasts was observed under transmission electron microscope. There was no significant difference in wound healing time between groups ( F =1.105, P =0.371). The mast cells number, collagen content, TGF-β 1 content, histamine content, and the I/III collagen content ratio in the early intervention group were significantly less than those in the other groups ( P 0.05). Compared with the control group, the activity of fibroblasts in the early intervention group was obviously inhibited, and the arrangement of the fibers was more regular; the fibroblast activity in the medium and late intervention groups was also inhibited obviously. Tranilast has no obvious effect on the wound healing time in mice. Tranilast intervention shows the inhibitory effect on the scar hyperplasia which can significantly reduce the number of mast cells, the content of histamine and TGF-β 1 , inhibit the ability of fibroblasts synthetic collagen and adjust the proportion of collagen synthesis. The immediate tranilast intervention may have the best inhibitory effect on scar hyperplasia.

  15. Transtendon rotator-cuff repair of partial-thickness articular surface tears can lead to medial rotator-cuff failure

    Directory of Open Access Journals (Sweden)

    Woods TC

    2014-06-01

    Full Text Available Tom C Woods,4 Michael J Carroll,1 Atiba A Nelson,2 Kristie D More,2 Randa Berdusco,1 Stephen Sohmer,3 Richard S Boorman,1,2 Ian KY Lo1,21Department of Surgery, 2Sport Medicine Centre, University of Calgary, Calgary, AB, Canada; 3Department of Orthopaedics, University of British Columbia, Vancouver, 4St Joseph's Hospital, Comox, BC, CanadaPurpose: The purpose of this study was to evaluate clinical and anatomic outcomes of patients following transtendon rotator-cuff repair of partial articular supraspinatus tendon avulsion (PASTA lesions.Patients and methods: Patients in the senior author's practice who had isolated PASTA lesions treated by transtendon rotator-cuff repair were included (n=8 and retrospectively reviewed. All patients were evaluated preoperatively and at a mean of 21.2 months (±9.7 months postoperatively using standardized clinical evaluation (physical exam, American Shoulder and Elbow Surgeons, and Simple Shoulder Test. All patients underwent postoperative imaging with a magnetic resonance imaging arthrogram.Results: There was a significant improvement in American Shoulder and Elbow Surgeons (42.7±17.5 to 86.9±25.2 and Simple Shoulder Test (4.6±3.2 to 10.1±3.8 scores from pre- to postoperative, respectively. Postoperative imaging demonstrated full-thickness medial cuff tearing in seven patients, and one patient with a persistent partial articular surface defect.Conclusion: Transtendon repair of PASTA lesions may lead to improvements in clinical outcome. However, postoperative imaging demonstrated a high incidence of full-thickness rotator-cuff defects following repair.Keywords: rotator cuff, PASTA lesion, transtendon repair

  16. Hydraulic jumps in a channel

    DEFF Research Database (Denmark)

    Bonn, D.; Andersen, Anders Peter; Bohr, Tomas

    2009-01-01

    We present a study of hydraulic jumps with flow predominantly in one direction, created either by confining the flow to a narrow channel with parallel walls or by providing an inflow in the form of a narrow sheet. In the channel flow, we find a linear height profile upstream of the jump as expected......'s mixing-length theory with a mixing length that is proportional to the height of the fluid layer. Using averaged boundary-layer equations, taking into account the friction with the channel walls and the eddy viscosity, the flow both upstream and downstream of the jump can be understood. For the downstream...... subcritical flow, we assume that the critical height is attained close to the channel outlet. We use mass and momentum conservation to determine the position of the jump and obtain an estimate which is in rough agreement with our experiment. We show that the averaging method with a varying velocity profile...

  17. Green channel cargo inspection system

    International Nuclear Information System (INIS)

    Shi Yuanping; Yu Jingsheng; Sun Hongqiang; Hao Pu; Cai Wenxia

    2011-01-01

    A radiation detection device was installed in the lanes of a highway toll station, radioactive rays which was collimated emitted through the measured, and arrived the detector. The average density of the fresh agricultural products belonged to Green channel and other prohibited items vary greatly, the absorption of radiation are different between the Green Channel Cargo and other substances. Prior to the experimental group, different standard samples which represent different models and goods were measured, the different standard samples were stored in a computer database. When the trucks get through the Green Channel, the detector will detect the radiation signal and bring to the computer, the computer will process the measured data, and make a conclusion whether the goods are Green Channel cargo. (authors)

  18. Flooding correlations in narrow channel

    International Nuclear Information System (INIS)

    Kim, S. H.; Baek, W. P.; Chang, S. H.

    1999-01-01

    Heat transfer in narrow gap is considered as important phenomena in severe accidents in nuclear power plants. Also in heat removal of electric chip. Critical heat flux(CHF) in narrow gap limits the maximum heat transfer rate in narrow channel. In case of closed bottom channel, flooding limited CHF occurrence is observed. Flooding correlations will be helpful to predict the CHF in closed bottom channel. In present study, flooding data for narrow channel geometry were collected and the work to recognize the effect of the span, w and gap size, s were performed. And new flooding correlations were suggested for high-aspect-ratio geometry. Also, flooding correlation was applied to flooding limited CHF data

  19. Multi-channel Kondo necklace

    International Nuclear Information System (INIS)

    Fazekas, P.; Kee Haeyoung.

    1993-06-01

    A multi-channel generalization of Doniach's Kondo necklace model is formulated, and its phase diagram studied in the mean-field approximation. Our intention is to introduce the possible simplest model which displays some of the features expected from the overscreened Kondo lattice. The N conduction electron channels are represented by N sets of pseudospins τ J , j = 1 1,..., N which are all antiferromagnetically coupled to a periodic array of modul S = 1/2 spins. Exploiting permutation symmetry in the channel index j allows us to write down the self-consistency equation for general N. For N > 2, we find that the critical temperature is rising with increasing Kondo interaction; we interpret this effect by pointing out that the Kondo coupling creates the composite pseudospin objects which undergo an ordering transition. The relevance of our findings to the underlying fermionic multi-channel problem is discussed. (author). 33 refs, 1 fig

  20. Experimentation with PEC channel prototype

    International Nuclear Information System (INIS)

    Caponetti, R.; Iacovelli, M.

    1984-01-01

    Experimentation on prototypes of PEC components is presently being carried out at Casaccia CRE. This report shows the results of the first cycle of experimentation of the central channel, concerning the aspects of sodium removal after experimentation

  1. Multi-channel Kondo necklace

    Energy Technology Data Exchange (ETDEWEB)

    Fazekas, P; Haeyoung, Kee

    1993-06-01

    A multi-channel generalization of Doniach`s Kondo necklace model is formulated, and its phase diagram studied in the mean-field approximation. Our intention is to introduce the possible simplest model which displays some of the features expected from the overscreened Kondo lattice. The N conduction electron channels are represented by N sets of pseudospins {tau}{sub J}, j = 1 1,..., N which are all antiferromagnetically coupled to a periodic array of modul S = 1/2 spins. Exploiting permutation symmetry in the channel index j allows us to write down the self-consistency equation for general N. For N > 2, we find that the critical temperature is rising with increasing Kondo interaction; we interpret this effect by pointing out that the Kondo coupling creates the composite pseudospin objects which undergo an ordering transition. The relevance of our findings to the underlying fermionic multi-channel problem is discussed. (author). 33 refs, 1 fig.

  2. FMCG companies specific distribution channels

    Directory of Open Access Journals (Sweden)

    Ioana Barin

    2009-12-01

    Full Text Available Distribution includes all activities undertaken by the producer, alone or in cooperation, since the end of the final finished products or services until they are in possession of consumers. The distribution consists of the following major components: distribution channels or marketing channels, which together form a distribution network; logistics o rphysical distribution. In order to effective achieve, distribution of goods requires an amount of activities and operational processes related to transit of goods from producer to consumer, the best conditions, using existing distribution channels and logistics system. One of the essential functions of a distribution is performing acts of sale, through which, with the actual movement of goods, their change of ownership takes place, that the successive transfer of ownership from producer to consumer. This is an itinerary in the economic cycle of goods, called the distribution channel.

  3. Marketing channel behaviour and performance

    OpenAIRE

    Duarte, Margarida

    2000-01-01

    Thesis submitted to University of Manchester for the degree of Doctor of Philosophy in the Faculty of Business Administration. A major aim of this study is to offer a relatively comprehensive picture of marketing channel behaviour and performance. Given the statistical difficulties in testing a very large, comprehensive model to achieve this aim, two separate but overlapping models are proposed. One model specifically addresses behaviour in marketing channels, while the other integrates k...

  4. Channel coincidence counter: version 1

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1980-06-01

    A thermal neutron coincidence counter has been designed for the assay of fast critical assembly fuel drawers and plutonium-bearing fuel rods. The principal feature of the detector is a 7-cm by 7-cm by 97-cm detector channel, which provides a uniform neutron detection efficiency of 16% along the central 40 cm of the channel. The electronics system is identical to that used for the High-Level Neutron Coincidence Counter

  5. TRP Channels in Human Prostate

    Directory of Open Access Journals (Sweden)

    Carl Van Haute

    2010-01-01

    Full Text Available This review gives an overview of morphological and functional characteristics in the human prostate. It will focus on the current knowledge about transient receptor potential (TRP channels expressed in the human prostate, and their putative role in normal physiology and prostate carcinogenesis. Controversial data regarding the expression pattern and the potential impact of TRP channels in prostate function, and their involvement in prostate cancer and other prostate diseases, will be discussed.

  6. Electrophysiological characterisation of KCNQ channel modulators

    DEFF Research Database (Denmark)

    Schrøder, R.L

    Potassium (K+) ion channels are ubiquitously expressed in mammalian cells, and each channel serves a precise physiological role due to its specific biophysical characteristics and expression pattern. A few K+ channels are targets for certain drugs, and in this thesis it is suggested that the KCNQ K......+ channels may be targets for neuroprotective, anti-epileptic and anti-nociceptive compounds. The importance of these channels is underscored by the fact that four out of five KCNQ channel subtypes are involved in severe human diseases. However, the pharmacology of the KCNQ channels is yet poorly understood...... as these channels were identified only recently. Therefore, there is a need for understanding the biophysical behavior and pharmacology of these ion channels. KCNQ channels belong to the group of voltage-activated K+ channels. The subfamily consists of KCNQ1-5, which is primarily expressed in the CNS, heart, ear...

  7. Uncertainty analysis for hot channel

    International Nuclear Information System (INIS)

    Panka, I.; Kereszturi, A.

    2006-01-01

    The fulfillment of the safety analysis acceptance criteria is usually evaluated by separate hot channel calculations using the results of neutronic or/and thermo hydraulic system calculations. In case of an ATWS event (inadvertent withdrawal of control assembly), according to the analysis, a number of fuel rods are experiencing DNB for a longer time and must be regarded as failed. Their number must be determined for a further evaluation of the radiological consequences. In the deterministic approach, the global power history must be multiplied by different hot channel factors (kx) taking into account the radial power peaking factors for each fuel pin. If DNB occurs it is necessary to perform a few number of hot channel calculations to determine the limiting kx leading just to DNB and fuel failure (the conservative DNBR limit is 1.33). Knowing the pin power distribution from the core design calculation, the number of failed fuel pins can be calculated. The above procedure can be performed by conservative assumptions (e.g. conservative input parameters in the hot channel calculations), as well. In case of hot channel uncertainty analysis, the relevant input parameters (k x, mass flow, inlet temperature of the coolant, pin average burnup, initial gap size, selection of power history influencing the gap conductance value) of hot channel calculations and the DNBR limit are varied considering the respective uncertainties. An uncertainty analysis methodology was elaborated combining the response surface method with the one sided tolerance limit method of Wilks. The results of deterministic and uncertainty hot channel calculations are compared regarding to the number of failed fuel rods, max. temperature of the clad surface and max. temperature of the fuel (Authors)

  8. Planar channeling in superlattices: Theory

    International Nuclear Information System (INIS)

    Ellison, J.A.; Picraux, S.T.; Allen, W.R.; Chu, W.K.

    1988-01-01

    The well-known continuum model theory for planar channeled energetic particles in perfect crystals is extended to layered crystalline structures and applied to superlattices. In a strained-layer structure, the planar channels with normals which are not perpendicular to the growth direction change their direction at each interface, and this dramatically influences the channeling behavior. The governing equation of motion for a planar channeled ion in a strained-layer superlattice with equal layer thicknesses is a one degree of freedom nonlinear oscillator which is periodically forced with a sequence of δ functions. These δ functions, which are of equal spacing and amplitude with alternating sign, represent the tilts at each of the interfaces. Thus upon matching an effective channeled particle wavelength, corresponding to a natural period of the nonlinear oscillator, to the period of the strained-layer superlattice, corresponding to the periodic forcing, strong resonance effects are expected. The condition of one effective wavelength per period corresponds to a rapid dechanneling at a well-defined depth (catastrophic dechanneling), whereas two wavelengths per period corresponds to no enhanced dechanneling after the first one or two layers (resonance channeling). A phase plane analysis is used to characterize the channeled particle motion. Detailed calculations using the Moliere continuum potential are compared with our previously described modified harmonic model, and new results are presented for the phase plane evolution, as well as the dechanneling as a function of depth, incident angle, energy, and layer thickness. General scaling laws are developed and nearly universal curves are obtained for the dechanneling versus depth under catastrophic dechanneling

  9. Volume of the space of qubit-qubit channels and state transformations under random quantum channels

    OpenAIRE

    Lovas, Attila; Andai, Attila

    2017-01-01

    The simplest building blocks for quantum computations are the qubit-qubit quantum channels. In this paper, we analyze the structure of these channels via their Choi representation. The restriction of a quantum channel to the space of classical states (i.e. probability distributions) is called the underlying classical channel. The structure of quantum channels over a fixed classical channel is studied, the volume of general and unital qubit channels with respect to the Lebesgue measure is comp...

  10. Information transfer through quantum channels

    International Nuclear Information System (INIS)

    Kretschmann, D.

    2007-01-01

    This PhD thesis represents work done between Aug. 2003 and Dec. 2006 in Reinhard F. Werner's quantum information theory group at Technische Universitaet Braunschweig, and Artur Ekert's Centre for Quantum Computation at the University of Cambridge. My thesis falls into the field of abstract quantum information theory. This work investigates both fundamental properties of quantum channels and their asymptotic capacities for classical as well as quantum information transfer. Stinespring's theorem is the basic structure theorem for quantum channels. It implies that every quantum channel can be represented as a unitary evolution on an enlarged system. In Ch. 3 we present a continuity theorem for Stinespring's representation: two quantum channels are similar if and only if it is possible to find unitary implementations that are likewise similar, with dimension-independent norm bounds. The continuity theorem allows to derive a formulation of the information-disturbance tradeoff in terms of quantum channels, and a continuity estimate for the no-broadcasting principle. In Ch. 4 we then apply the continuity theorem to give a strengthened no-go proof for quantum bit commitment, an important cryptographic primitive. This result also provides a natural characterization of those protocols that fall outside the standard setting of unconditional security, and thus may allow secure bit commitment. We present a new such protocol whose security relies on decoherence in the receiver's lab. Ch. 5 reviews the capacities of quantum channels for the transfer of both classical and quantum information, and investigates several variations in the notion of channel capacity. Memory effects are then investigated in detail in Ch. 6. We advertise a model which is sufficiently general to encompass all causal automata: every quantum process in which the outputs up to any given time t do not depend on the inputs at times t'>t can be represented as a concatenated memory channel. We then explain how

  11. Information transfer through quantum channels

    Energy Technology Data Exchange (ETDEWEB)

    Kretschmann, D.

    2007-03-12

    This PhD thesis represents work done between Aug. 2003 and Dec. 2006 in Reinhard F. Werner's quantum information theory group at Technische Universitaet Braunschweig, and Artur Ekert's Centre for Quantum Computation at the University of Cambridge. My thesis falls into the field of abstract quantum information theory. This work investigates both fundamental properties of quantum channels and their asymptotic capacities for classical as well as quantum information transfer. Stinespring's theorem is the basic structure theorem for quantum channels. It implies that every quantum channel can be represented as a unitary evolution on an enlarged system. In Ch. 3 we present a continuity theorem for Stinespring's representation: two quantum channels are similar if and only if it is possible to find unitary implementations that are likewise similar, with dimension-independent norm bounds. The continuity theorem allows to derive a formulation of the information-disturbance tradeoff in terms of quantum channels, and a continuity estimate for the no-broadcasting principle. In Ch. 4 we then apply the continuity theorem to give a strengthened no-go proof for quantum bit commitment, an important cryptographic primitive. This result also provides a natural characterization of those protocols that fall outside the standard setting of unconditional security, and thus may allow secure bit commitment. We present a new such protocol whose security relies on decoherence in the receiver's lab. Ch. 5 reviews the capacities of quantum channels for the transfer of both classical and quantum information, and investigates several variations in the notion of channel capacity. Memory effects are then investigated in detail in Ch. 6. We advertise a model which is sufficiently general to encompass all causal automata: every quantum process in which the outputs up to any given time t do not depend on the inputs at times t'>t can be represented as a concatenated memory

  12. A Crash Course in Calcium Channels.

    Science.gov (United States)

    Zamponi, Gerald W

    2017-12-20

    Much progress has been made in understanding the molecular physiology and pharmacology of calcium channels. Recently, there have been tremendous advances in learning about calcium channel structure and function through crystallography and cryo-electron microscopy studies. Here, I will give an overview of our knowledge about calcium channels, and highlight two recent studies that give important insights into calcium channel structure.

  13. Transient receptor potential channels in essential hypertension

    DEFF Research Database (Denmark)

    Liu, Daoyan; Scholze, Alexandra; Zhu, Zhiming

    2006-01-01

    The role of nonselective cation channels of the transient receptor potential channel (TRPC) family in essential hypertension has not yet been investigated.......The role of nonselective cation channels of the transient receptor potential channel (TRPC) family in essential hypertension has not yet been investigated....

  14. The minimum yield in channeling

    International Nuclear Information System (INIS)

    Uguzzoni, A.; Gaertner, K.; Lulli, G.; Andersen, J.U.

    2000-01-01

    A first estimate of the minimum yield was obtained from Lindhard's theory, with the assumption of a statistical equilibrium in the transverse phase-space of channeled particles guided by a continuum axial potential. However, computer simulations have shown that this estimate should be corrected by a fairly large factor, C (approximately equal to 2.5), called the Barrett factor. We have shown earlier that the concept of a statistical equilibrium can be applied to understand this result, with the introduction of a constraint in phase-space due to planar channeling of axially channeled particles. Here we present an extended test of these ideas on the basis of computer simulation of the trajectories of 2 MeV α particles in Si. In particular, the gradual trend towards a full statistical equilibrium is studied. We also discuss the introduction of this modification of standard channeling theory into descriptions of the multiple scattering of channeled particles (dechanneling) by a master equation and show that the calculated minimum yields are in very good agreement with the results of a full computer simulation

  15. Generic theory for channel sinuosity.

    Science.gov (United States)

    Lazarus, Eli D; Constantine, José Antonio

    2013-05-21

    Sinuous patterns traced by fluid flows are a ubiquitous feature of physical landscapes on Earth, Mars, the volcanic floodplains of the Moon and Venus, and other planetary bodies. Typically discussed as a consequence of migration processes in meandering rivers, sinuosity is also expressed in channel types that show little or no indication of meandering. Sinuosity is sometimes described as "inherited" from a preexisting morphology, which still does not explain where the inherited sinuosity came from. For a phenomenon so universal as sinuosity, existing models of channelized flows do not explain the occurrence of sinuosity in the full variety of settings in which it manifests, or how sinuosity may originate. Here we present a generic theory for sinuous flow patterns in landscapes. Using observations from nature and a numerical model of flow routing, we propose that flow resistance (representing landscape roughness attributable to topography or vegetation density) relative to surface slope exerts a fundamental control on channel sinuosity that is effectively independent of internal flow dynamics. Resistance-dominated surfaces produce channels with higher sinuosity than those of slope-dominated surfaces because increased resistance impedes downslope flow. Not limited to rivers, the hypothesis we explore pertains to sinuosity as a geomorphic pattern. The explanation we propose is inclusive enough to account for a wide variety of sinuous channel types in nature, and can serve as an analytical tool for determining the sinuosity a landscape might support.

  16. Charged and Neutral Particles Channeling Phenomena Channeling 2008

    Science.gov (United States)

    Dabagov, Sultan B.; Palumbo, Luigi

    2010-04-01

    On the discovery of coherent Bremsstrahlung in a single crystal at the Frascati National Laboratories / C. Barbiellini, G. P. Murtas and S. B. Dabagov -- Advances in coherent Bremsstrahlung and LPM-effect studies (to the lOOth anniversary from the birth of L. D. Landau) / N. F. Shul'ga -- Spectra of radiation and created particles at intermediate energy in oriented crystal taking into account energy loss / V. N. Baier and V. M. Katkov -- The coherent Bremsstrahlung beam at MAX-lab facility / K. Fissum ... [et al.] -- Radiation from thin, structured targets (CERN NA63) / A. Dizdar -- Hard incoherent radiation in thick crystals / N. F. Shul'ga, V. V. Syshchenko and A. I. Tarnovsky -- Coherent Bremsstrahlung in periodically deformed crystals with a complex base / A. R. Mkrtchyan, A. A. Saharian and V. V. Parazian -- Induction of coherent x-ray Bremsstrahlung in crystals under the influence of acoustic waves / A. R. Mkrtchyan and V. V. Parazian -- Coherent processes in bent single crystals / V. A. Maisheev -- Experimental and theoretical investigation of complete transfer phenomenon for media with various heat exchange coefficients / A. R. Mkrtchyan, A. E. Movsisyan and V. R. Kocharyan -- Coherent pair production in crystals / A. R. Mkrtchyan, A. A. Saharian and V. V. Parazian -- Negative particle planar and axial channeling and channeling collimation / R. A. Carrigan, Jr. -- CERN crystal-based collimation in modern hadron colliders / W. Scandale -- Studies and application of bent crystals for beam steering at 70 GeV IHEP accelerator / A. G. Afonin ... [et al.] -- Crystal collimation studies at the Tevatron (T-980) / N. V. Mokhov ... [et al.] -- Fabrication of crystals for channeling of particles in accellerators / A. Mazzolari ... [et al.] -- New possibilities to facilitate collimation of both positively and negatively charged particle beams by crystals / V. Guidi, A. Mazzolari and V. V. Tikhomirov -- Increase of probability of particle capture into the channeling

  17. Pannexin-1 channels in epilepsy.

    Science.gov (United States)

    Aquilino, Mark S; Whyte-Fagundes, Paige; Zoidl, Georg; Carlen, Peter L

    2017-09-05

    Pannexin-1 (Panx1) expression is raised in several animal seizure models and in resected human epileptic brain tissue, suggesting relevance to epilepsy. Multiple factors that are characteristic of seizures are thought to regulate Panx1 channel opening, including elevated levels of extracellular K + . Panx1, when open, 1) releases ATP, glutamate, and other metabolites into the extracellular medium, and 2) may depolarize the membrane due to a channel reversal potential around 0mV. Resultant ATP release from stimulated Panx1 can activate purinergic receptors, including P2X7 receptors. Glutamate and other signaling molecules released by Panx1 opening may have both excitatory and inhibitory actions on seizure generation. This review examines the critical and complex roles of Panx1 channels in epilepsy, which could provide a basis for future therapeutics. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Axial channeling of uttrarelativistic electrons

    Energy Technology Data Exchange (ETDEWEB)

    Telegin, V.I.; Khokonov, M.Kh. (Moskovskij Gosudarstvennyj Univ. (USSR). Nauchno-Issledovatel' skij Inst. Yadernoj Fiziki)

    1982-07-01

    The dynamics of motion of ultrarelativistic electrons under axial channeling conditions is investigated. The analysis is based on the solution of the kinetic equation obtained recently by Beloshitsky and Kumakhov. The particle dechanneling function is investigated as depending on the type of a crystal, particle energy and angle of entrance into the single crystal. It is found that for most of the beam the major diffusion mechanism is scattering by electrons. It is shown that an optimal depth range exists for which the fraction of channeled particles sharply increases at the expense of the quasi-channeled particles. In a number of cases the dechanneling length for crystals with high atomic numbers may be greater than that of light elements.

  19. Axial channeling of uttrarelativistic electrons

    International Nuclear Information System (INIS)

    Telegin, V.I.; Khokonov, M.Kh.

    1982-01-01

    The dynamics of motion of ultrarelativistic electrons under axial channeling conditions is investigated. The analysis is based on the solution of the kinetic equation obtained recently by Beloshitsky and Kumakhov. The particle dechanneling function is investigated as depending on the type of a crystal, particle energy and angle of entrance into the single crystal. It is found that for most of the beam the major diffusion mechanism is scattering by electrons. It is shown that an optimal depth range exists for which the fraction of channeled particles sharply increases at the expense of the quasi-channeled particles. In a number of cases the dechanneling length for crystals with high atomic numbers may be greater than that of light elements

  20. Pharmacological modulation of SK3 channels

    DEFF Research Database (Denmark)

    Grunnet, M; Jespersen, Thomas; Angelo, K

    2001-01-01

    Small-conductance, calcium-activated K+ channels (SK channels) are voltage-insensitive channels that have been identified molecularly within the last few years. As SK channels play a fundamental role in most excitable cells and participate in afterhyperpolarization (AHP) and spike-frequency adapt...... at concentrations of 3 microM and above. Amitriptyline, a tricyclic antidepressive widely used clinically, inhibits SK3 channels with an IC50 of 39.1 +/- 10 microM (n=6)....

  1. Local quantum channels preserving classical correlations

    International Nuclear Information System (INIS)

    Guo Zhihua; Cao Huaixin

    2013-01-01

    The aim of this paper is to discuss local quantum channels that preserve classical correlations. First, we give two equivalent characterizations of classical correlated states. Then we obtain the relationships among classical correlation-preserving local quantum channels, commutativity-preserving local quantum channels and commutativity-preserving quantum channels on each subsystem. Furthermore, for a two-qubit system, we show the general form of classical correlation-preserving local quantum channels. (paper)

  2. The ion-channel laser

    International Nuclear Information System (INIS)

    Whittum, D.H.; Sessler, A.M.; Dawson, J.M.

    1990-01-01

    A relativistic electron beam propagating through a plasma in the ion-focused regime exhibits an electromagnetic instability at a resonant frequency ω ∼ 2γ 2 ω β . Growth is enhanced by optical guiding in the ion channel, which acts as dielectric waveguide, with fiber parameter V ∼ 2 (I/I A ) 1/2 . A 1-D theory for such an ''ion-channel laser'' is formulated, scaling laws are derived and numerical examples are given. Possible experimental evidence is noted. 23 refs., 1 fig., 1 tab

  3. Electron angular distribution axial channeling

    International Nuclear Information System (INIS)

    Khokonov, A.Kh.; Khokonov, M.Kh.

    1989-01-01

    Angular distributions of ultra-relativistic electrons are calculated in the assumption about presence of statistical equilibrium. Analysis is based on numerical solution of Fokker-Planck type kinetic equation. It is shown that in contrast to case of amorphous medium, the multiple scattering at axial channeling of negative particles results in self-focusing of the initial beam particles and due to it number of electrons moving at an angles to the chain, which are smaller, than critical angle of channeling, may increase by several times as compared to the initial one

  4. Antenna for Ultrawideband Channel Sounding

    DEFF Research Database (Denmark)

    Zhekov, Stanislav Stefanov; Tatomirescu, Alexandru; Pedersen, Gert F.

    2016-01-01

    A novel compact antenna for ultrawideband channel sounding is presented. The antenna is composed of a symmetrical biconical antenna modified by adding a cylinder and a ring to each cone. A feeding coaxial cable is employed during the simulations in order to evaluate and reduce its impact on the a......A novel compact antenna for ultrawideband channel sounding is presented. The antenna is composed of a symmetrical biconical antenna modified by adding a cylinder and a ring to each cone. A feeding coaxial cable is employed during the simulations in order to evaluate and reduce its impact...

  5. Importância do co-cultivo com fibroblastos de camundongo 3T3 para estabelecer cultura de suspensão de células epiteliais do limbo humano Importance of 3T3 feeder layer to establish epithelial cultures from cell suspension obtained from corneo-scleral rims

    Directory of Open Access Journals (Sweden)

    Priscila Cardoso Cristovam

    2008-10-01

    Full Text Available OBJETIVO: Avaliar a importância da presença de células 3T3 para estabelecer cultura de suspensão de células epiteliais do limbo obtido de rimas córneo-esclerais. MÉTODOS: Rimas de diferentes doadores tiveram seus estroma posterior e endotélio removidos (n=6. Cada rima foi dividida em três segmentos iguais, que foram colocados em cultura em três diferentes condições: um segmento foi colocado na placa de cultura com o lado epitelial para cima (Grupo A. Os dois segmentos restantes foram tripsinizados e a suspensão de células obtida foi cultivada com (Grupo B ou sem (Grupo C células 3T3 irradiadas. As células foram mantidas em meio de cultura "supplemental hormonal epithelial médium" (SHEM, a migração epitelial e a formação de clones nos grupos A, B e C foram avaliadas pela microscopia de contraste de fase e por coloração pela rodamina B. Os resultados foram comparados estatisticamente. RESULTADOS: O crescimento de células epiteliais foi observado em 4/6 rimas (Grupo A. Todas as suspensões de células epiteliais que foram cultivadas com células 3T3 (Grupo B formaram clones. Nenhuma adesão ou formação de clones verdadeiros (holo ou meroclones foi observada na cultura de células que foi cultivada sem 3T3 (Grupo C (p=0,009. CONCLUSÕES: Suspensão de células epiteliais límbicas obtidas de rimas córneo-esclerais no modelo utilizado precisa ser cultivada com células 3T3 para formar clones e estabelecer colônias epiteliais com perspectivas para uso terapêutico na reconstrução da superfície ocular.PURPOSE: To evaluate the importance of the presence of 3T3 fibroblasts for establishing limbal epithelial cultures from cell suspension obtained from corneo-scleral rims (CSR. METHODS: Corneo-scleral rims from different donors (n=6 had their posterior stroma and endothelium stripped away. Each corneo-scleral rim was divided into three equal segments that were set up in tissue culture in three different conditions: one of the

  6. EPICS: Channel Access security design

    International Nuclear Information System (INIS)

    Kraimer, M.; Hill, J.

    1994-05-01

    This document presents the design for implementing the requirements specified in: EPICS -- Channel Access Security -- functional requirements, Ned. D. Arnold, 03/09/92. Use of the access security system is described along with a summary of the functional requirements. The programmer's interface is given. Security protocol is described and finally aids for reading the access security code are provided

  7. Improved Ion-Channel Biosensors

    Science.gov (United States)

    Nadeau, Jay; White, Victor; Dougherty, Dennis; Maurer, Joshua

    2004-01-01

    An effort is underway to develop improved biosensors of a type based on ion channels in biomimetic membranes. These sensors are microfabricated from silicon and other materials compatible with silicon. As described, these sensors offer a number of advantages over prior sensors of this type.

  8. Single top t-channel

    CERN Document Server

    Faltermann, Nils

    2017-01-01

    The production of single top quarks allows to study the interplay of top quark physics and the electroweak sector of the standard model. Deviations from predictions can be a hint for physics beyond the standard model. The t-channel is the dominant production mode for single top quarks at the LHC. This talk presents the latest measurements from the ATLAS and CMS collaborations.

  9. Visualizing multi-channel networks

    DEFF Research Database (Denmark)

    Antemijczuk, Paweł; Magiera, Marta; Jørgensen, Sune Lehmann

    2014-01-01

    In this paper, we propose a visualization to illustrate social interactions, built from multiple distinct channels of communication. The visualization displays a summary of dense personal information in a compact graphical notation. The starting point is an abstract drawing of a spider’s web. Below...

  10. CHANNELING IN QUASI-CRYSTALS

    NARCIS (Netherlands)

    VANVOORTHUYSEN, EHD; SMULDERS, PJM; WERKMAN, RD; DEBOER, JL; VANSMAALEN, S

    Ion-beam channeling has been observed in quasicrystals. For 1 MeV He-4+ ions in icosahedral AlCuFe the maximum effect found is 36%. The full width at half maximum of the observed dips is 1.3-degrees. The effect persists up to great depths (> 200 nm), thus showing a high degree of ordering in this

  11. Sorting out river channel patterns

    NARCIS (Netherlands)

    Kleinhans, M.G.

    2010-01-01

    Rivers self-organize their pattern/planform through feedbacks between bars, channels, floodplain and vegetation, which emerge as a result of the basic spatial sorting process of wash load sediment and bed sediment. The balance between floodplain formation and destruction determines the width and

  12. Aquaglyceroporins: ancient channels for metalloids

    Science.gov (United States)

    Bhattacharjee, Hiranmoy; Mukhopadhyay, Rita; Thiyagarajan, Saravanamuthu; Rosen, Barry P

    2008-01-01

    The identification of aquaglyceroporins as uptake channels for arsenic and antimony shows how these toxic elements can enter the food chain, and suggests that food plants could be genetically modified to exclude arsenic while still accumulating boron and silicon. PMID:19014407

  13. Sales promotions and channel coordination

    NARCIS (Netherlands)

    B. Wierenga (Berend); H. Soethoudt (Han)

    2009-01-01

    textabstractConsumer sales promotions are usually the result of the decisions of two marketing channel parties, the manufacturer and the retailer. In making these decisions, each party normally follows its own interest: i.e. maximizes its own profit. Unfortunately, this results in a suboptimal

  14. Sales promotion and channel coordination

    NARCIS (Netherlands)

    Wierenga, B.; Soethoudt, J.M.

    2010-01-01

    Consumer sales promotions are usually the result of the decisions of two marketing channel parties, the manufacturer and the retailer. In making these decisions, each party normally follows its own interest: i.e. maximizes its own profit. Unfortunately, this results in a suboptimal outcome for the

  15. CONDUCTIVE CHANNEL FOR ENERGY TRANSMISSION

    Directory of Open Access Journals (Sweden)

    V. V. Apollonov

    2014-01-01

    Full Text Available Laser spark obtained by using a conical optics is much more appropriate to form conducting channels in atmosphere. Only two types of lasers are actively considered to be used in forming high-conductivity channels in atmosphere, controlled by laser spark: pulsed sub-microsecond gas and chemical lasers (CO2, DF and short pulse solid-state and UV lasers. Main advantage of short pulse lasers is their ability in forming of super long ionized channels with a characteristic diameter of ~100  µ  in atmosphere along the  beam propagation direction. At estimated electron densities below  10 ⋅ 16 cm–3 in these filaments and laser wavelengths in the range of 0,5–1,0 mm, the plasma barely absorbs laser radiation.  In this case, the length of the track composed of many filaments is determined by the laser intensity and may reach many kilometers at a femtosecond pulse energy of ~100 mJ. However, these lasers could not be used to form high-conductivity long channels in atmosphere. The ohmic resistance of this type a conducting channels turned out to be very high, and the gas in the channels could not be strongly heated (< 1 J. An electric breakdown controlled by radiation of femtosecond solid-state laser was implemented in only at a length of 3 m with a voltage of 2 MV across the discharge gap (670 kV/m.Not so long ago scientific group from P. N. Lebedev has improved that result, the discharge gap – 1 m had been broken under KrF laser irradiation when switching high-voltage (up to 390 kV/m electric discharge by 100-ns UV pulses. Our previous result  –  16 m long conducting channel controlled by a  laser spark at the voltage  –  3 MV  – was obtained more than 20 years ago in Russia and Japan by using pulsed CO2  laser with energy  –  0,5 kJ. An average electric field strength  was < 190 kV/m. It is still too much for efficient applications.

  16. Interior point decoding for linear vector channels

    International Nuclear Information System (INIS)

    Wadayama, T

    2008-01-01

    In this paper, a novel decoding algorithm for low-density parity-check (LDPC) codes based on convex optimization is presented. The decoding algorithm, called interior point decoding, is designed for linear vector channels. The linear vector channels include many practically important channels such as inter-symbol interference channels and partial response channels. It is shown that the maximum likelihood decoding (MLD) rule for a linear vector channel can be relaxed to a convex optimization problem, which is called a relaxed MLD problem

  17. Interior point decoding for linear vector channels

    Energy Technology Data Exchange (ETDEWEB)

    Wadayama, T [Nagoya Institute of Technology, Gokiso, Showa-ku, Nagoya, Aichi, 466-8555 (Japan)], E-mail: wadayama@nitech.ac.jp

    2008-01-15

    In this paper, a novel decoding algorithm for low-density parity-check (LDPC) codes based on convex optimization is presented. The decoding algorithm, called interior point decoding, is designed for linear vector channels. The linear vector channels include many practically important channels such as inter-symbol interference channels and partial response channels. It is shown that the maximum likelihood decoding (MLD) rule for a linear vector channel can be relaxed to a convex optimization problem, which is called a relaxed MLD problem.

  18. The MISO wiretap channel with channel uncertainty: Asymptotic perspectives

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alomair, Basel; Alouini, Mohamed-Slim

    2017-01-01

    The N-antenna MISO Gaussian wiretap channel with imperfect channel-state information at the transmitter (CSIT) is studied in terms of secrecy rate scaling versus the signal-to-noise ratio (SNR) and N. Two schemes are considered, beamforming (BF) and artificial noise injection (AN). It is shown that if the CSIT error is independent of SNR, then both schemes do not achieve scaling versus SNR. However, if this error vanishes as SNR increases, then AN achieves the optimal scaling versus SNR, contrary to BF. Scaling can be achieved in BF by increasing N. In fact, BF achieves the optimal scaling versus N. In the AN scheme however, injecting noise in multiple direction deteriorates its scaling versus N. Nevertheless, AN can achieve the optimal scaling if noise is sent in only one direction. This leads to better performance than BF if the CSIT error is smaller than a threshold which is also derived.

  19. The MISO wiretap channel with channel uncertainty: Asymptotic perspectives

    KAUST Repository

    Chaaban, Anas

    2017-05-12

    The N-antenna MISO Gaussian wiretap channel with imperfect channel-state information at the transmitter (CSIT) is studied in terms of secrecy rate scaling versus the signal-to-noise ratio (SNR) and N. Two schemes are considered, beamforming (BF) and artificial noise injection (AN). It is shown that if the CSIT error is independent of SNR, then both schemes do not achieve scaling versus SNR. However, if this error vanishes as SNR increases, then AN achieves the optimal scaling versus SNR, contrary to BF. Scaling can be achieved in BF by increasing N. In fact, BF achieves the optimal scaling versus N. In the AN scheme however, injecting noise in multiple direction deteriorates its scaling versus N. Nevertheless, AN can achieve the optimal scaling if noise is sent in only one direction. This leads to better performance than BF if the CSIT error is smaller than a threshold which is also derived.

  20. An Effective Channel Allocation Scheme to Reduce Co-Channel and Adjacent Channel Interference for WMN Backhaul

    International Nuclear Information System (INIS)

    Abbasi, S.; Ismaili, I.A.; Khuhawar, F.Y.

    2016-01-01

    Two folded work presents channel allocation scheme sustaining channel orthogonality and channel spacing to reduce CCI (Co-Channel Interference) and ACI (Adjacent Channel Interference) for inter flow of an intra-flow link. Proposed scheme as a part of radio resource allocation is applied on infrastructure based backhaul of wireless mesh network using directional antennas. The proposed approach is applied separately on 2.4 and 5GHz bands. Interference of connectivity graph is modelled by strongly connected directed graph and greedy algorithms are used for channel allocation. We have used OPNET Modeller suite to simulate network models for this research. The proposed arrangement reduces the channel interference and increases system throughput. In this research, the influence of channel is computed in terms of network throughput and delay. (author)

  1. Clofilium inhibits Slick and Slack potassium channels.

    Science.gov (United States)

    de Los Angeles Tejada, Maria; Stolpe, Kathleen; Meinild, Anne-Kristine; Klaerke, Dan A

    2012-01-01

    Slick and Slack high-conductance potassium channels have been recently discovered, and are found in the central nervous system and in the heart. Both channels are activated by Na(+) and Cl(-), and Slick channels are also inhibited by adenosine triphospate (ATP). An important role of setting the resting membrane potential and controlling the basal excitability of neurons has been suggested for these channels. In addition, no specific blockers for these channels are known up to the present. With the purpose of studying the pharmacological characteristics of Slick and Slack channels, the effects of exposure to the antiarrhythmic compound clofilium were evaluated. Clofilium was able to modulate the activity of Slick and Slack channels effectively, with a stronger effect on Slack than Slick channels. In order to evaluate the pharmacological behavior of Slick and Slack channels further, 38 commonly used potassium channel blockers were tested. Screening of these compounds did not reveal any modulators of Slick and Slack channels, except for clofilium. The present study provides a first approach towards elucidating the pharmacological characteristics of Slick and Slack channels and could be the basis for future studies aimed at developing potent and specific blockers and activators for these channels.

  2. Targeting sodium channels in cardiac arrhythmia

    NARCIS (Netherlands)

    Remme, Carol Ann; Wilde, Arthur A. M.

    2014-01-01

    Cardiac voltage-gated sodium channels are responsible for proper electrical conduction in the heart. During acquired pathological conditions and inherited sodium channelopathies, altered sodium channel function causes conduction disturbances and ventricular arrhythmias. Although the clinical,

  3. Matagorda Ship Channel, Texas: Jetty Stability Study

    National Research Council Canada - National Science Library

    Kraus, Nicholas C; Lin, Lihwa; Batten, Brian K; Brown, Gary L

    2006-01-01

    .... The current has produced a large area of scour on the bay side of the inlet adjacent to the west jetty, and vessels encountering a strong along-channel and cross-channel current at the entrance...

  4. Quantum Correlations Evolution Asymmetry in Quantum Channels

    International Nuclear Information System (INIS)

    Li Meng; Huang Yun-Feng; Guo Guang-Can

    2017-01-01

    It was demonstrated that the entanglement evolution of a specially designed quantum state in the bistochastic channel is asymmetric. In this work, we generalize the study of the quantum correlations, including entanglement and quantum discord, evolution asymmetry to various quantum channels. We found that the asymmetry of entanglement and quantum discord only occurs in some special quantum channels, and the behavior of the entanglement evolution may be quite different from the behavior of the quantum discord evolution. To quantum entanglement, in some channels it decreases monotonously with the increase of the quantum channel intensity. In some other channels, when we increase the intensity of the quantum channel, it decreases at first, then keeps zero for some time, and then rises up. To quantum discord, the evolution becomes more complex and you may find that it evolutes unsmoothly at some points. These results illustrate the strong dependence of the quantum correlations evolution on the property of the quantum channels. (paper)

  5. Coastal Maintained Channels in US waters

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This layer shows coastal channels and waterways that are maintained and surveyed by the U.S. Army Corps of Engineers (USACE). These channels are necessary...

  6. Channel Estimation in DCT-Based OFDM

    Science.gov (United States)

    Wang, Yulin; Zhang, Gengxin; Xie, Zhidong; Hu, Jing

    2014-01-01

    This paper derives the channel estimation of a discrete cosine transform- (DCT-) based orthogonal frequency-division multiplexing (OFDM) system over a frequency-selective multipath fading channel. Channel estimation has been proved to improve system throughput and performance by allowing for coherent demodulation. Pilot-aided methods are traditionally used to learn the channel response. Least square (LS) and mean square error estimators (MMSE) are investigated. We also study a compressed sensing (CS) based channel estimation, which takes the sparse property of wireless channel into account. Simulation results have shown that the CS based channel estimation is expected to have better performance than LS. However MMSE can achieve optimal performance because of prior knowledge of the channel statistic. PMID:24757439

  7. Channel CAT: A Tactical Link Analysis Tool

    National Research Council Canada - National Science Library

    Coleman, Michael

    1997-01-01

    .... This thesis produced an analysis tool, the Channel Capacity Analysis Tool (Channel CAT), designed to provide an automated tool for the analysis of design decisions in developing client-server software...

  8. Investigation Of Information Sources And Communication Channels ...

    African Journals Online (AJOL)

    Investigation Of Information Sources And Communication Channels In Ipm Rice ... the information accessibility of farmer groups seems as empowerment strategy. ... information sources and communication channels, in order of importance, ...

  9. The KATP channel in migraine pathophysiology

    DEFF Research Database (Denmark)

    Al-Karagholi, Mohammad Al-Mahdi; Hansen, Jakob Møller; Severinsen, Johanne

    2017-01-01

    BACKGROUND: To review the distribution and function of KATP channels, describe the use of KATP channels openers in clinical trials and make the case that these channels may play a role in headache and migraine. DISCUSSION: KATP channels are widely present in the trigeminovascular system and play...... an important role in the regulation of tone in cerebral and meningeal arteries. Clinical trials using synthetic KATP channel openers report headache as a prevalent-side effect in non-migraine sufferers, indicating that KATP channel opening may cause headache, possibly due to vascular mechanisms. Whether KATP...... channel openers can provoke migraine in migraine sufferers is not known. CONCLUSION: We suggest that KATP channels may play an important role in migraine pathogenesis and could be a potential novel therapeutic anti-migraine target....

  10. Optimization of Communication in Noisy Quantum Channels

    National Research Council Canada - National Science Library

    Ruskai, Mary

    2002-01-01

    .... This project has been concerned with the analysis of mathematical models of noise for qubit channels, with the capacity of qubit channels used to transmit classical information, and with exchange...

  11. Four-channel delay generator model 5740

    International Nuclear Information System (INIS)

    Baumatz, D.; Milner, M.

    1978-01-01

    The 4-channel delay generator model 5740 generates 4-pulse groups in independent channels. The device offers the possibility of controlling both the time intervals between the pulses of a group and the rate of generation of groups

  12. Channelling of flow through fractures in rock

    International Nuclear Information System (INIS)

    Bourke, P.J.

    1987-05-01

    A method of mapping the channelling of flow in rock fractures formed by contacts between rock faces and of measuring the effective apertures of channels has been developed. Some typical results are given. (author)

  13. Consolidation equipment for irradiated nuclear fuel channels

    International Nuclear Information System (INIS)

    Taguchi, M.; Komatsu, Y.; Ose, T.

    1989-01-01

    The authors have developed and put into use a new type of mechanical consolidation equipment for irradiated nuclear fuel channels. This includes round-slice cutting of the top 100mm of the fuel channel with a guillotine cutter, and press cutting of the two corners of the remaining length of the fuel channel. Four guillotine blades work in combination with receiving blades arranged inside the fuel channel to cut the top 100mm, including the clips and spacers, of the fuel channel into a round slice. A press assembled in the consolidation equipment then presses the slice to achieve volume reduction. The press cutting operation uses two press cutting blades arranged inside the fuel channel and the receiving blades outside the fuel channel. The remaining length of fuel channel is cut off into L-shaped pieces by press cutting. This consolidation equipment is highly efficient because the round-slice cutting, pressing, and press cutting are all achieved by one unit

  14. Channeling experiments at IPNE Cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, F; Dumitru, M; Ivan, A [Cyclotron Laboratory, Institute of Atomic Physics, Institute of Physics and Nuclear Engineering, R-76900 Bucharest, P.O.Box MG-6, (Romania)

    1992-01-01

    Channeling experiments have been performed at the I.P.N.E Cyclotron using a 3 MeV alpha beam. A slide system cut the beam up to 5 minutes spatial resolution with a maximum 60 nA beam current on the target. The two-axis goniometer, fully computer-controlled, moves the target, a silicon wafer, with 2.5 minute resolution, while an alpha particle sensitive solid state detector, monitors the backscattered particle fluence. In the first stage, channeling appears to be a simple, fast and reliable method for precise monocrystal orientation. A reduction of the host yield by a factor of two allowed impurities and defects to be studied. (Author).

  15. Thermoelectricity in Heterogeneous Nanofluidic Channels.

    Science.gov (United States)

    Li, Long; Wang, Qinggong

    2018-05-01

    Ionic fluids are essential to energy conversion, water desalination, drug delivery, and lab-on-a-chip devices. Ionic transport in nanoscale confinements and complex physical fields still remain elusive. Here, a nanofluidic system is developed using nanochannels of heterogeneous surface properties to investigate transport properties of ions under different temperatures. Steady ionic currents are observed under symmetric temperature gradients, which is equivalent to generating electricity using waste heat (e.g., electronic chips and solar panels). The currents increase linearly with temperature gradient and nonlinearly with channel size. Contributions to ion motion from temperatures and channel properties are evaluated for this phenomenon. The findings provide insights into the study of confined ionic fluids in multiphysical fields, and suggest applications in thermal energy conversion, temperature sensors, and chip-level thermal management. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Improving Channel Coordination Through Franchising

    OpenAIRE

    Rajiv Lal

    1990-01-01

    In this paper, we explore the role of franchising arrangements in improving coordination between channel members. In particular we focus on two elements of the franchising contract, namely, the royalty structure and the monitoring technology. We begin with a simple analysis where a manufacturer distributes its product through a retailer and the retail demand is affected by the retail price and the service provided by the retailer. In this context we show that neither royalty payments nor moni...

  17. Digital Multi Channel Analyzer Enhancement

    International Nuclear Information System (INIS)

    Gonen, E.; Marcus, E.; Wengrowicz, U.; Beck, A.; Nir, J.; Sheinfeld, M.; Broide, A.; Tirosh, D.

    2002-01-01

    A cement analyzing system based on radiation spectroscopy had been developed [1], using novel digital approach for real-time, high-throughput and low-cost Multi Channel Analyzer. The performance of the developed system had a severe problem: the resulted spectrum suffered from lack of smoothness, it was very noisy and full of spikes and surges, therefore it was impossible to use this spectrum for analyzing the cement substance. This paper describes the work carried out to improve the system performance

  18. Trafficking of neuronal calcium channels

    Czech Academy of Sciences Publication Activity Database

    Weiss, Norbert; Zamponi, G. W.

    2017-01-01

    Roč. 1, č. 1 (2017), č. článku NS20160003. ISSN 2059-6553 R&D Projects: GA ČR GA15-13556S; GA MŠk 7AMB15FR015 Institutional support: RVO:61388963 Keywords : calcium channel * neuron * trafficing Subject RIV: ED - Physiology OBOR OECD: Physiology (including cytology) http://www.neuronalsignaling.org/content/1/1/NS20160003

  19. Spark channel propagation in a microbubble liquid

    Energy Technology Data Exchange (ETDEWEB)

    Panov, V. A.; Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru; Vetchinin, S. P.; Pecherkin, V. Ya.; Son, E. E. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2016-11-15

    Experimental study on the development of the spark channel from the anode needle under pulsed electrical breakdown of isopropyl alcohol solution in water with air microbubbles has been performed. The presence of the microbubbles increases the velocity of the spark channel propagation and increases the current in the discharge gap circuit. The observed rate of spark channel propagation in microbubble liquid ranges from 4 to 12 m/s, indicating the thermal mechanism of the spark channel development in a microbubble liquid.

  20. Assessing the Consequences of a Channel Switch

    OpenAIRE

    Xinlei (Jack) Chen; George John; Om Narasimhan

    2008-01-01

    Switching marketing channels is an expensive and sticky decision. While a number of theories suggest efficiency and strategic differences between channels, there is virtually no work on combining these ideas into an empirically workable methodology to assess the impact of a channel switch. In this study, we undertake to close this gap with an empirical study of the sports drink market, featuring competing producers and heterogeneous channels. We estimate demand and cost parameters for a numbe...

  1. Degenerate RFID Channel Modeling for Positioning Applications

    Directory of Open Access Journals (Sweden)

    A. Povalac

    2012-12-01

    Full Text Available This paper introduces the theory of channel modeling for positioning applications in UHF RFID. It explains basic parameters for channel characterization from both the narrowband and wideband point of view. More details are given about ranging and direction finding. Finally, several positioning scenarios are analyzed with developed channel models. All the described models use a degenerate channel, i.e. combined signal propagation from the transmitter to the tag and from the tag to the receiver.

  2. Channel CAT: A Tactical Link Analysis Tool

    Science.gov (United States)

    1997-09-01

    NAVAL POSTGRADUATE SCHOOL Monterey, California THESIS CHANNEL CAT : A TACTICAL LINK ANALYSIS TOOL by Michael Glenn Coleman September 1997 Thesis...REPORT TYPE AND DATES COVERED September 1997 Master’s Thesis 4. TITLE AND SUBTITLE CHANNEL CAT : A TACTICAL LINK ANALYSIS TOOL 5. FUNDING NUMBERS 6...tool, the Channel Capacity Analysis Tool (Channel CAT ), designed to provide an automated tool for the anlysis of design decisions in developing client

  3. Optimal super dense coding over memory channels

    OpenAIRE

    Shadman, Zahra; Kampermann, Hermann; Macchiavello, Chiara; Bruß, Dagmar

    2011-01-01

    We study the super dense coding capacity in the presence of quantum channels with correlated noise. We investigate both the cases of unitary and non-unitary encoding. Pauli channels for arbitrary dimensions are treated explicitly. The super dense coding capacity for some special channels and resource states is derived for unitary encoding. We also provide an example of a memory channel where non-unitary encoding leads to an improvement in the super dense coding capacity.

  4. Radio propagation measurement and channel modelling

    CERN Document Server

    Salous, Sana

    2013-01-01

    While there are numerous books describing modern wireless communication systems that contain overviews of radio propagation and radio channel modelling, there are none that contain detailed information on the design, implementation and calibration of radio channel measurement equipment, the planning of experiments and the in depth analysis of measured data. The book would begin with an explanation of the fundamentals of radio wave propagation and progress through a series of topics, including the measurement of radio channel characteristics, radio channel sounders, measurement strategies

  5. Spin chain model for correlated quantum channels

    Energy Technology Data Exchange (ETDEWEB)

    Rossini, Davide [International School for Advanced Studies SISSA/ISAS, via Beirut 2-4, I-34014 Trieste (Italy); Giovannetti, Vittorio; Montangero, Simone [NEST-CNR-INFM and Scuola Normale Superiore, Piazza dei Cavalieri 7, I-56126 Pisa (Italy)], E-mail: monta@sns.it

    2008-11-15

    We analyze the quality of the quantum information transmission along a correlated quantum channel by studying the average fidelity between input and output states and the average output purity, giving bounds for the entropy of the channel. Noise correlations in the channel are modeled by the coupling of each channel use with an element of a one-dimensional interacting quantum spin chain. Criticality of the environment chain is seen to emerge in the changes of the fidelity and of the purity.

  6. Subunit Stoichiometry of Human Muscle Chloride Channels

    OpenAIRE

    Fahlke, Christoph; Knittle, Timothy; Gurnett, Christina A.; Campbell, Kevin P.; George, Alfred L.

    1997-01-01

    Voltage-gated Cl? channels belonging to the ClC family appear to function as homomultimers, but the number of subunits needed to form a functional channel is controversial. To determine subunit stoichiometry, we constructed dimeric human skeletal muscle Cl? channels in which one subunit was tagged by a mutation (D136G) that causes profound changes in voltage-dependent gating. Sucrose-density gradient centrifugation experiments indicate that both monomeric and dimeric hClC-1 channels in their ...

  7. Hollow core plasma channel generation

    International Nuclear Information System (INIS)

    Quast, Heinrich Martin

    2018-03-01

    The use of a hollow plasma channel in plasma-based acceleration has beneficial properties for the acceleration of electron and positron bunches. In the scope of the FLASHForward facility at DESY, the generation of such a plasma structure is examined. Therefore, the generation of a ring-shaped laser intensity profile with different techniques is analyzed. From the obtained intensity profiles the electron density of a hollow plasma channel is simulated in the focal region. Different parameters are scanned to understand their influence on the electron density distribution - an important parameter being, for example, the radius of the central region of the channel. In addition to the simulations, experiments are presented, during which a laser pulse is transformed into a hollow beam with a spiral phase plate. Subsequently, it forms a plasma during the interaction with hydrogen, where the plasma is imaged with interferometry. For energies above 0.9 mJ a hollow plasma structure can be observed at the location of first plasma formation.

  8. Local Transfer Coefficient, Smooth Channel

    Directory of Open Access Journals (Sweden)

    R. T. Kukreja

    1998-01-01

    Full Text Available Naphthalene sublimation technique and the heat/mass transfer analogy are used to determine the detailed local heat/mass transfer distributions on the leading and trailing walls of a twopass square channel with smooth walls that rotates about a perpendicular axis. Since the variation of density is small in the flow through the channel, buoyancy effect is negligible. Results show that, in both the stationary and rotating channel cases, very large spanwise variations of the mass transfer exist in he turn and in the region immediately downstream of the turn in the second straight pass. In the first straight pass, the rotation-induced Coriolis forces reduce the mass transfer on the leading wall and increase the mass transfer on the trailing wall. In the turn, rotation significantly increases the mass transfer on the leading wall, especially in the upstream half of the turn. Rotation also increases the mass transfer on the trailing wall, more in the downstream half of the turn than in the upstream half of the turn. Immediately downstream of the turn, rotation causes the mass transfer to be much higher on the trailing wall near the downstream corner of the tip of the inner wall than on the opposite leading wall. The mass transfer in the second pass is higher on the leading wall than on the trailing wall. A slower flow causes higher mass transfer enhancement in the turn on both the leading and trailing walls.

  9. Study of material properties using channeling radiation

    International Nuclear Information System (INIS)

    Pantell, R.H.; Kephart, J.O.; Klein, R.K.; Park, H.; Berman, B.L.; Datz, S.

    1986-01-01

    A possible application for channeling radiation is for investigating the properties of crystals in which the channeling occurs. In this paper we present some general considerations concerning channeling radiation as a measurement technique, and then we proceed to describe several specific examples

  10. Square root approximation to the poisson channel

    NARCIS (Netherlands)

    Tsiatmas, A.; Willems, F.M.J.; Baggen, C.P.M.J.

    2013-01-01

    Starting from the Poisson model we present a channel model for optical communications, called the Square Root (SR) Channel, in which the noise is additive Gaussian with constant variance. Initially, we prove that for large peak or average power, the transmission rate of a Poisson Channel when coding

  11. The Marketing Channels of China Auto Industry

    Institute of Scientific and Technical Information of China (English)

    our reporter

    2001-01-01

    <正> After the 1990’s, the multi-channel structure of sales has still existed although the market mechanism is playing a main role in Chinese auto marketing circulation. Now, the channels of automobile marketing in China are as follows: 1. Manufacturer-established marketing channels

  12. Molecular determinants in TRPV5 channel assembly.

    NARCIS (Netherlands)

    Chang, Q.; Gyftogianni, E.; Graaf, K.F.J. van de; Hoefs, S.J.G.; Weidema, A.F.; Bindels, R.J.M.; Hoenderop, J.G.J.

    2004-01-01

    The epithelial Ca(2+) channels TRPV5 and TRPV6 mediate the Ca(2+) influx in 1,25-dihydroxyvitamin D(3)-responsive epithelia and are therefore essential in the maintenance of the body Ca(2+) balance. These Ca(2+) channels assemble in (hetero)tetrameric channel complexes with different functional

  13. Molecular determinants in TRPV5 channel assembly

    NARCIS (Netherlands)

    Chang, Qing; Gyftogianni, Emmanouela; van de Graaf, Stan F. J.; Hoefs, Susan; Weidema, Freek A.; Bindels, René J. M.; Hoenderop, Joost G. J.

    2004-01-01

    The epithelial Ca(2+) channels TRPV5 and TRPV6 mediate the Ca(2+) influx in 1,25-dihydroxyvitamin D(3)-responsive epithelia and are therefore essential in the maintenance of the body Ca(2+) balance. These Ca(2+) channels assemble in (hetero)tetrameric channel complexes with different functional

  14. Electronic Commerce and Retail Channel Substitution

    NARCIS (Netherlands)

    M.C.W. Janssen (Maarten); R. van der Noll

    2002-01-01

    textabstractWe analyze a market where firms compete in a conventional and an electronic retail channel. Consumers easily compare prices online, but some incur purchase uncertainties on the online channel. We investigate the market shares of the two retail channels and the prices that are charged. We

  15. 47 CFR 95.29 - Channels available.

    Science.gov (United States)

    2010-10-01

    ... with no more than 5 watts ERP. (g) Fixed stations in GMRS systems authorized before March 18, 1968... transmission of another GMRS station on a different channel or channels), the licensee of the GMRS system must... GMRS system from the following 462 MHz channels: 462.5500, 462.5750, 462.6000, 462.6250, 462.6500, 462...

  16. Mechanosensitive Channels: In Touch with Piezo

    OpenAIRE

    Xiao, Rui; Xu, X.Z. Shawn

    2010-01-01

    Mechanosensory transduction underlies touch, hearing and proprioception and requires mechanosensitive channels that are directly gated by forces; however, the molecular identities of these channels remain largely elusive. A new study has identified Piezo1 and Piezo2 as a novel class of mechanosensitive channels.

  17. Language Planning, Channel Management, and ESP.

    Science.gov (United States)

    Kennedy, Chris

    Channel management, a concept developed in marketing to refer to the process by which a product is moved from production to consumption, uses a channel of distribution operating at several levels, each responsible for one or more of the activities of moving the product forward to the consumer. The function of channel management is to select the…

  18. Separation of Particles in Channels Rotary Engine

    Directory of Open Access Journals (Sweden)

    Zyatikov Pavel

    2015-01-01

    Full Text Available The article considers the separation of particles in channels with different relative length. It is shown that the intensity of turbulence at the inlet section of the channel varies considerably in its length. The dependence of the turbulence damping along the channel expressing by fraction of the distance is shown. The ratio of the particle separation efficiency out the gas flow in the rotor channel is defined. The values of particle separation efficiency in the channel for the angle α=π/4 in turbulent aerosol flow is shows, including without mixing the particles.

  19. CHANNEL EVOLUTION IN MODIFIED ALLUVIAL STREAMS.

    Science.gov (United States)

    Simon, Andrew; Hupp, Cliff R.

    1987-01-01

    This study (a) assesses the channel changes and network trends of bed level response after modifications between 1959 and 1972 of alluvial channels in western Tennessee and (b) develops a conceptual model of bank slope development to qualitatively assess bank stability and potential channel widening. A six-step, semiquantitative model of channel evolution in disturbed channels was developed by quantifying bed level trends and recognizing qualitative stages of bank slope development. Development of the bank profile is defined in terms of three dynamic and observable surfaces: (a) vertical face (70 to 90 degrees), (b) upper bank (25 to 50 degrees), and (c) slough line (20 to 25 degrees).

  20. Modulation of ERG channels by XE991

    DEFF Research Database (Denmark)

    Elmedyb, Pernille; Calloe, Kirstine; Schmitt, Nicole

    2007-01-01

    In neuronal tissue, KCNQ2-5 channels conduct the physiologically important M-current. In some neurones, the M-current may in addition be conducted partly by ERG potassium channels, which have widely overlapping expression with the KCNQ channel subunits. XE991 and linopiridine are known to be stan......In neuronal tissue, KCNQ2-5 channels conduct the physiologically important M-current. In some neurones, the M-current may in addition be conducted partly by ERG potassium channels, which have widely overlapping expression with the KCNQ channel subunits. XE991 and linopiridine are known...... to be standard KCNQ potassium channel blockers. These compounds have been used in many different tissues as specific pharmacological tools to discern native currents conducted by KCNQ channels from other potassium currents. In this article, we demonstrate that ERG1-2 channels are also reversibly inhibited by XE......991 in the micromolar range (EC(50) 107 microM for ERG1). The effect has been characterized in Xenopus laevis oocytes expressing ERG1-2 and in the mammalian HEK293 cell line stably expressing ERG1 channels. The IC(50) values for block of KCNQ channels by XE991 range 1-65 microM. In conclusion, great...

  1. Plasma channels for electron beam transport

    International Nuclear Information System (INIS)

    Schneider, R.F.; Smith, J.R.; Moffatt, M.E.; Nguyen, K.T.; Uhm, H.S.

    1988-01-01

    In recent years, there has been much interest in transport of intense relativistic electron beams using plasma channels. These channels are formed by either: ionization of an organic gas by UV photoionization or electron impact ionization of a low pressure gas utilizing a low energy (typically several hundred volts) electron gun. The second method is discussed here. As their electron gun, the authors used a 12 volt lightbulb filament which is biased to -400 volts with respect to the grounded 15 cm diameter drift tube. The electrons emitted from the filament are confined by an axial magnetic field of --100 Gauss to create a plasma channel which is less than 1 cm in radius. The channel density has been determined with Langmuir probes and the resulting line densities were found to be 10 11 to 10 12 per cm. When a multi-kiloamp electron beam is injected onto this channel, the beam space charge will eject the plasma electrons leaving the ions behind to charge neutralize the electron beam, hence allowing the beam to propagate. In this work, the authors performed experimental studies on the dynamics of the plasma channel. These include Langmuir probe measurements of a steady state (DC) channel, as well as time-resolved Langmuir probe studies of pulsed channels. In addition they performed experimental studies of beam propagation in these plasma channels. Specifically, they observed the behavior of current transport in these channels. Detailed results of beam transport and channel studies are presented

  2. Post-Translational Modifications of TRP Channels

    Directory of Open Access Journals (Sweden)

    Olaf Voolstra

    2014-04-01

    Full Text Available Transient receptor potential (TRP channels constitute an ancient family of cation channels that have been found in many eukaryotic organisms from yeast to human. TRP channels exert a multitude of physiological functions ranging from Ca2+ homeostasis in the kidney to pain reception and vision. These channels are activated by a wide range of stimuli and undergo covalent post-translational modifications that affect and modulate their subcellular targeting, their biophysical properties, or channel gating. These modifications include N-linked glycosylation, protein phosphorylation, and covalent attachment of chemicals that reversibly bind to specific cysteine residues. The latter modification represents an unusual activation mechanism of ligand-gated ion channels that is in contrast to the lock-and-key paradigm of receptor activation by its agonists. In this review, we summarize the post-translational modifications identified on TRP channels and, when available, explain their physiological role.

  3. Quantum capacity of Pauli channels with memory

    International Nuclear Information System (INIS)

    Huang Peng; He Guangqiang; Lu Yuan; Zeng Guihua

    2011-01-01

    The amount of coherent quantum information that can be reliably transmitted down the memory Pauli channels with Markovian correlated noise is investigated. Two methods for evaluating the quantum capacity of the memory Pauli channels are proposed to try to trace the memory effect on the transmissions of quantum information. We show that the evaluation of quantum capacity can be reduced to the calculation of the initial memory state of each successive transmission. Furthermore, we derive quantum capacities of the memory phase flip channel, bit flip channel and bit-phase flip channel. Also, a lower bound of the quantum capacity of the memory depolarizing channel is obtained. An increase of the degree of memory of the channels has a positive effect on the increase of their quantum capacities.

  4. Effects of dislocations on electron channeling

    International Nuclear Information System (INIS)

    George, Juby; Pathak, A P

    2009-01-01

    The phenomenon of electron channeling in a crystal affected by dislocations is considered. Earlier we had considered the quantum aspects of the positron channeling in a crystal bent by dislocations where the effects of longitudinal motion of the particle were also considered along with the transverse motion. In this paper, the effective potential for the electron case is found for the two regions of dislocation-affected channel. There is considerable shift in the potential minima due to dislocations. The frequency and the corresponding spectrum of the channeling radiation due to electrons channeling through the perfect channel and the two regions of dislocation-affected channels are calculated. The spectral distribution of radiation intensity changes with the parameters of dislocation. The continuity of wavefunctions and their derivatives is used at the three boundaries and the reflection and transmission coefficients are found using these boundary conditions in the same way as in the positron case.

  5. Channel selection for automatic seizure detection

    DEFF Research Database (Denmark)

    Duun-Henriksen, Jonas; Kjaer, Troels Wesenberg; Madsen, Rasmus Elsborg

    2012-01-01

    Objective: To investigate the performance of epileptic seizure detection using only a few of the recorded EEG channels and the ability of software to select these channels compared with a neurophysiologist. Methods: Fifty-nine seizures and 1419 h of interictal EEG are used for training and testing...... of an automatic channel selection method. The characteristics of the seizures are extracted by the use of a wavelet analysis and classified by a support vector machine. The best channel selection method is based upon maximum variance during the seizure. Results: Using only three channels, a seizure detection...... sensitivity of 96% and a false detection rate of 0.14/h were obtained. This corresponds to the performance obtained when channels are selected through visual inspection by a clinical neurophysiologist, and constitutes a 4% improvement in sensitivity compared to seizure detection using channels recorded...

  6. On luminescence bleaching of tidal channel sediments

    DEFF Research Database (Denmark)

    Fruergaard, Mikkel; Pejrup, Morten; Murray, Andrew S.

    2015-01-01

    We investigate the processes responsible for bleaching of the quartz OSL signal from tidal channel sediment. Tidal dynamics are expected to play an important role for complete bleaching of tidal sediments. However, no studies have examined the amount of reworking occurring in tidal channels...... and on tidal flats due to the mixing caused by currents and waves. We apply bed level data to evaluate the amount of vertical sediment reworking in modern tidal channels and at a tidal flat. Cycles of deposition and erosion are measured with a bed level sensor, and the results show that gross sedimentation...... was several times higher than net sedimentation. We propose that tidal channel sediment is bleached either on the tidal flat before it is transported to the tidal channels and incorporated in channel-fill successions or, alternatively, on the shallow intertidal part of the channel banks. Based...

  7. Anion channels: master switches of stress responses.

    Science.gov (United States)

    Roelfsema, M Rob G; Hedrich, Rainer; Geiger, Dietmar

    2012-04-01

    During stress, plant cells activate anion channels and trigger the release of anions across the plasma membrane. Recently, two new gene families have been identified that encode major groups of anion channels. The SLAC/SLAH channels are characterized by slow voltage-dependent activation (S-type), whereas ALMT genes encode rapid-activating channels (R-type). Both S- and R-type channels are stimulated in guard cells by the stress hormone ABA, which leads to stomatal closure. Besides their role in ABA-dependent stomatal movement, anion channels are also activated by biotic stress factors such as microbe-associated molecular patterns (MAMPs). Given that anion channels occur throughout the plant kingdom, they are likely to serve a general function as master switches of stress responses. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Quantum channels with a finite memory

    International Nuclear Information System (INIS)

    Bowen, Garry; Mancini, Stefano

    2004-01-01

    In this paper we study quantum communication channels with correlated noise effects, i.e., quantum channels with memory. We derive a model for correlated noise channels that includes a channel memory state. We examine the case where the memory is finite, and derive bounds on the classical and quantum capacities. For the entanglement-assisted and unassisted classical capacities it is shown that these bounds are attainable for certain classes of channel. Also, we show that the structure of any finite-memory state is unimportant in the asymptotic limit, and specifically, for a perfect finite-memory channel where no information is lost to the environment, achieving the upper bound implies that the channel is asymptotically noiseless

  9. Multicarrier chaotic communications in multipath fading channels without channel estimation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shilian, E-mail: wangsl@nudt.edu.cn; Zhang, Zhili [College of Electrical Science and Engineering, National University of Defense Technology, Changsha, 410073, P R China (China)

    2015-01-15

    A multi-carrier chaotic shift keying(MC-CSK) communication scheme with low probability of interception(LPI) is proposed in this article. We apply chaotic spreading sequences in the frequency domain, mapping a different chip of a chaotic sequence to an individual orthogonal frequency division multiplexing(OFDM) subcarrier. In each block size of $M$ OFDM symbols, we use one pilot OFDM symbol inserted time-spaced in all-frequency to transmit the reference chaotic signal and use the other M-1 OFDM symbols to transmit the information-bearing signals each spreaded by the reference chaotic signal. At the receiver, we construct a differential detector after DFT and recover the information bits from the correlations between the pilot OFDM symbol and the other M-1 OFDM symbols in each block size of M. Performance analysis and computer simulations show that the MC-CSK outperforms differential chaos shift keying(DCSK) in AWGN channels with high bandwidth efficiency for the block size of M=2 and that the MC-CSK exploits effectively the frequent diversity of the multipath channel.

  10. Multicarrier chaotic communications in multipath fading channels without channel estimation

    Directory of Open Access Journals (Sweden)

    Shilian Wang

    2015-01-01

    Full Text Available A multi-carrier chaotic shift keying(MC-CSK communication scheme with low probability of interception(LPI is proposed in this article. We apply chaotic spreading sequences in the frequency domain, mapping a different chip of a chaotic sequence to an individual orthogonal frequency division multiplexing(OFDM subcarrier. In each block size of $M$ OFDM symbols, we use one pilot OFDM symbol inserted time-spaced in all-frequency to transmit the reference chaotic signal and use the other M-1 OFDM symbols to transmit the information-bearing signals each spreaded by the reference chaotic signal. At the receiver, we construct a differential detector after DFT and recover the information bits from the correlations between the pilot OFDM symbol and the other M-1 OFDM symbols in each block size of M. Performance analysis and computer simulations show that the MC-CSK outperforms differential chaos shift keying(DCSK in AWGN channels with high bandwidth efficiency for the block size of M=2 and that the MC-CSK exploits effectively the frequent diversity of the multipath channel.

  11. Precipitation patterns during channel flow

    Science.gov (United States)

    Jamtveit, B.; Hawkins, C.; Benning, L. G.; Meier, D.; Hammer, O.; Angheluta, L.

    2013-12-01

    Mineral precipitation during channelized fluid flow is widespread in a wide variety of geological systems. It is also a common and costly phenomenon in many industrial processes that involve fluid flow in pipelines. It is often referred to as scale formation and encountered in a large number of industries, including paper production, chemical manufacturing, cement operations, food processing, as well as non-renewable (i.e. oil and gas) and renewable (i.e. geothermal) energy production. We have studied the incipient stages of growth of amorphous silica on steel plates emplaced into the central areas of the ca. 1 meter in diameter sized pipelines used at the hydrothermal power plant at Hellisheidi, Iceland (with a capacity of ca 300 MW electricity and 100 MW hot water). Silica precipitation takes place over a period of ca. 2 months at approximately 120°C and a flow rate around 1 m/s. The growth produces asymmetric ca. 1mm high dendritic structures ';leaning' towards the incoming fluid flow. A novel phase-field model combined with the lattice Boltzmann method is introduced to study how the growth morphologies vary under different hydrodynamic conditions, including non-laminar systems with turbulent mixing. The model accurately predicts the observed morphologies and is directly relevant for understanding the more general problem of precipitation influenced by turbulent mixing during flow in channels with rough walls and even for porous flow. Reference: Hawkins, C., Angheluta, L., Hammer, Ø., and Jamtveit, B., Precipitation dendrites in channel flow. Europhysics Letters, 102, 54001

  12. Multiple channel programmable coincidence counter

    Science.gov (United States)

    Arnone, Gaetano J.

    1990-01-01

    A programmable digital coincidence counter having multiple channels and featuring minimal dead time. Neutron detectors supply electrical pulses to a synchronizing circuit which in turn inputs derandomized pulses to an adding circuit. A random access memory circuit connected as a programmable length shift register receives and shifts the sum of the pulses, and outputs to a serializer. A counter is input by the adding circuit and downcounted by the seralizer, one pulse at a time. The decoded contents of the counter after each decrement is output to scalers.

  13. Mechanosensitive gating of Kv channels.

    Directory of Open Access Journals (Sweden)

    Catherine E Morris

    Full Text Available K-selective voltage-gated channels (Kv are multi-conformation bilayer-embedded proteins whose mechanosensitive (MS Popen(V implies that at least one conformational transition requires the restructuring of the channel-bilayer interface. Unlike Morris and colleagues, who attributed MS-Kv responses to a cooperative V-dependent closed-closed expansion↔compaction transition near the open state, Mackinnon and colleagues invoke expansion during a V-independent closed↔open transition. With increasing membrane tension, they suggest, the closed↔open equilibrium constant, L, can increase >100-fold, thereby taking steady-state Popen from 0→1; "exquisite sensitivity to small…mechanical perturbations", they state, makes a Kv "as much a mechanosensitive…as…a voltage-dependent channel". Devised to explain successive gK(V curves in excised patches where tension spontaneously increased until lysis, their L-based model falters in part because of an overlooked IK feature; with recovery from slow inactivation factored in, their g(V datasets are fully explained by the earlier model (a MS V-dependent closed-closed transition, invariant L≥4. An L-based MS-Kv predicts neither known Kv time courses nor the distinctive MS responses of Kv-ILT. It predicts Kv densities (hence gating charge per V-sensor several-fold different from established values. If opening depended on elevated tension (L-based model, standard gK(V operation would be compromised by animal cells' membrane flaccidity. A MS V-dependent transition is, by contrast, unproblematic on all counts. Since these issues bear directly on recent findings that mechanically-modulated Kv channels subtly tune pain-related excitability in peripheral mechanoreceptor neurons we undertook excitability modeling (evoked action potentials. Kvs with MS V-dependent closed-closed transitions produce nuanced mechanically-modulated excitability whereas an L-based MS-Kv yields extreme, possibly excessive

  14. Use of navigation channels by Lake Sturgeon: Does channelization increase vulnerability of fish to ship strikes?

    Directory of Open Access Journals (Sweden)

    Darryl W Hondorp

    Full Text Available Channelization for navigation and flood control has altered the hydrology and bathymetry of many large rivers with unknown consequences for fish species that undergo riverine migrations. In this study, we investigated whether altered flow distributions and bathymetry associated with channelization attracted migrating Lake Sturgeon (Acipenser fulvescens into commercial navigation channels, potentially increasing their exposure to ship strikes. To address this question, we quantified and compared Lake Sturgeon selection for navigation channels vs. alternative pathways in two multi-channel rivers differentially affected by channelization, but free of barriers to sturgeon movement. Acoustic telemetry was used to quantify Lake Sturgeon movements. Under the assumption that Lake Sturgeon navigate by following primary flow paths, acoustic-tagged Lake Sturgeon in the more-channelized lower Detroit River were expected to choose navigation channels over alternative pathways and to exhibit greater selection for navigation channels than conspecifics in the less-channelized lower St. Clair River. Consistent with these predictions, acoustic-tagged Lake Sturgeon in the more-channelized lower Detroit River selected the higher-flow and deeper navigation channels over alternative migration pathways, whereas in the less-channelized lower St. Clair River, individuals primarily used pathways alternative to navigation channels. Lake Sturgeon selection for navigation channels as migratory pathways also was significantly higher in the more-channelized lower Detroit River than in the less-channelized lower St. Clair River. We speculated that use of navigation channels over alternative pathways would increase the spatial overlap of commercial vessels and migrating Lake Sturgeon, potentially enhancing their vulnerability to ship strikes. Results of our study thus demonstrated an association between channelization and the path use of migrating Lake Sturgeon that could prove

  15. Estudo prospectivo comparativo de duas técnicas cirúrgicas de extração extra-capsular planejada de catarata com implante de lente intra-ocular: incisão limbar e incisão escleral tunelizada Prospective comparative study of two techniques of planned extracapsular cataract extraction: limbal incision and scleral tunnel incision

    Directory of Open Access Journals (Sweden)

    Lincoln Lemes Freitas

    2001-06-01

    extraction (ECCE with posterior chamber intraocular lens implantation. This study aims to compare limbal incision and scleral tunnel incision in planned ECCE. Methods: Fifty-four consecutive patients (59 eyes with follow-up of 6 months were studied prospectively. ECCE with limbal incision was performed in 30 patients (Group I, and with scleral tunnel incision in 29 patients (Group II. Corrected visual acuity, intraocular inflammation (cells and flare, surgical time, specular microscopy, induced astigmatism and pachymetry were assessed. Results: Surgical time, endothelial cells loss and induced astigmatism were statistically greater in group I than in group II. No significant differences were found between groups when comparing the corrected visual acuity, intraocular inflammation and pachymetry. Conclusions: ECCE with scleral tunnel incision technique offers advantages regarding surgical time, endothelial cells loss and induced astigmatism if compared with limbal incision technique. Surgical steps used in this technique help in transition for phacoemulsification with low cost and a safer way.

  16. 间接镜氪激光光凝结合改进宽环扎治疗视网膜脱离%Krypton laser photocoagulation using indirect ophthalmoscopy combined with improved encircling scleral buckles in the treatment of retinal detachment

    Institute of Scientific and Technical Information of China (English)

    郑穗联; 陈如; 王若洁; 蔡剑秋; 施明光

    2011-01-01

    Objective To assess the clinical result of the krypton laser photocoagulation using indirect ophthalmoscopy combined with improved encircling scleral buckles.Methods Forty-one eyes of 41 patients were treated with encircling scleral buckles and drainage, some combined with intravitreal injection of gas or balanced salt solution (BSS).All of the retinal breaks were treated with krypton laser photocoagulation using indirect ophthalmoscopy after surgery.Results The visual acuity improved (P<0.05).The reattachment of the retina: 36 eyes were successfully repaired, 5 eyes became recurrent retinal detachment (the reattachment rate was 88.37%).Among the 5 cases, 4 patients were successfully treated with vitrectomy except one patient of traumatic retinal detachment was given up.Conclusions The treatment of retinal detachment should follow the principles of simple surgical methods and fewer complications.The krypton laser photocoagulation using indirect ophthalmoscopy combined with improved encircling scleral buckles in the treatment of retinal detachment in proper cases is a safe, simple and convenient, easy operated and effective method.%目的 讨论采用间接镜氪激光光凝结合改进宽环扎治疗视网膜脱离的临床疗效.方法 对41例41只眼PVRB级或以下的孔源性视网膜脱离病人行宽环扎、放液,部分病人联合玻璃体腔注气或平衡液,术后间接镜氪激光治疗视网膜裂孔.结果 视力提高:术后视力为3.87±0.74,术前视力为3.40±0.86,P<0.05.视网膜复位情况:41只眼中手术成功36只眼,5只眼复发性,成功率88.37%.5只眼复发性视网膜脱离,除1例外伤性视网膜脱离放弃手术外,其余患者均行玻璃体手术后复位.结论 对视网膜脱离术我们建议遵循手术方式简单、并发症少的原则.选择适当病例,间接镜氪激光光凝结合改进宽环扎治疗视网膜脱离是一种安全、简便、易操作、效果良好的方法.

  17. ASIC3 channels in multimodal sensory perception.

    Science.gov (United States)

    Li, Wei-Guang; Xu, Tian-Le

    2011-01-19

    Acid-sensing ion channels (ASICs), which are members of the sodium-selective cation channels belonging to the epithelial sodium channel/degenerin (ENaC/DEG) family, act as membrane-bound receptors for extracellular protons as well as nonproton ligands. At least five ASIC subunits have been identified in mammalian neurons, which form both homotrimeric and heterotrimeric channels. The highly proton sensitive ASIC3 channels are predominantly distributed in peripheral sensory neurons, correlating with their roles in multimodal sensory perception, including nociception, mechanosensation, and chemosensation. Different from other ASIC subunit composing ion channels, ASIC3 channels can mediate a sustained window current in response to mild extracellular acidosis (pH 7.3-6.7), which often occurs accompanied by many sensory stimuli. Furthermore, recent evidence indicates that the sustained component of ASIC3 currents can be enhanced by nonproton ligands including the endogenous metabolite agmatine. In this review, we first summarize the growing body of evidence for the involvement of ASIC3 channels in multimodal sensory perception and then discuss the potential mechanisms underlying ASIC3 activation and mediation of sensory perception, with a special emphasis on its role in nociception. We conclude that ASIC3 activation and modulation by diverse sensory stimuli represent a new avenue for understanding the role of ASIC3 channels in sensory perception. Furthermore, the emerging implications of ASIC3 channels in multiple sensory dysfunctions including nociception allow the development of new pharmacotherapy.

  18. A Perspective on the MIMO Wiretap Channel

    KAUST Repository

    Oggier, Frederique; Hassibi, Babak

    2015-01-01

    A wiretap channel is a communication channel between a transmitter Alice and a legitimate receiver Bob, in the presence of an eavesdropper Eve. The goal of communication is to achieve reliability between Alice and Bob, but also confidentiality despite Eve’s presence. Wiretap channels are declined in all kinds of flavors, depending on the underlying channels used by the three players: discrete memoryless channels, additive Gaussian noise channels, or fading channels, to name a few. In this survey, we focus on the case where the three players use multiple-antenna channels with Gaussian noise to communicate. After summarizing known results for multiple-input–multiple-output (MIMO) channels, both in terms of achievable reliable data rate (capacity) and code design, we introduce the MIMO wiretap channel. We then state the MIMO wiretap capacity, summarize the idea of the proof(s) behind this result, and comment on the insights given by the proofs on the physical meaning of the secrecy capacity. We finally discuss design criteria for MIMO wiretap codes.

  19. VKCDB: Voltage-gated potassium channel database

    Directory of Open Access Journals (Sweden)

    Gallin Warren J

    2004-01-01

    Full Text Available Abstract Background The family of voltage-gated potassium channels comprises a functionally diverse group of membrane proteins. They help maintain and regulate the potassium ion-based component of the membrane potential and are thus central to many critical physiological processes. VKCDB (Voltage-gated potassium [K] Channel DataBase is a database of structural and functional data on these channels. It is designed as a resource for research on the molecular basis of voltage-gated potassium channel function. Description Voltage-gated potassium channel sequences were identified by using BLASTP to search GENBANK and SWISSPROT. Annotations for all voltage-gated potassium channels were selectively parsed and integrated into VKCDB. Electrophysiological and pharmacological data for the channels were collected from published journal articles. Transmembrane domain predictions by TMHMM and PHD are included for each VKCDB entry. Multiple sequence alignments of conserved domains of channels of the four Kv families and the KCNQ family are also included. Currently VKCDB contains 346 channel entries. It can be browsed and searched using a set of functionally relevant categories. Protein sequences can also be searched using a local BLAST engine. Conclusions VKCDB is a resource for comparative studies of voltage-gated potassium channels. The methods used to construct VKCDB are general; they can be used to create specialized databases for other protein families. VKCDB is accessible at http://vkcdb.biology.ualberta.ca.

  20. Mechanosensitive Piezo Channels in the Gastrointestinal Tract.

    Science.gov (United States)

    Alcaino, C; Farrugia, G; Beyder, A

    2017-01-01

    Sensation of mechanical forces is critical for normal function of the gastrointestinal (GI) tract and abnormalities in mechanosensation are linked to GI pathologies. In the GI tract there are several mechanosensitive cell types-epithelial enterochromaffin cells, intrinsic and extrinsic enteric neurons, smooth muscle cells and interstitial cells of Cajal. These cells use mechanosensitive ion channels that respond to mechanical forces by altering transmembrane ionic currents in a process called mechanoelectrical coupling. Several mechanosensitive ionic conductances have been identified in the mechanosensory GI cells, ranging from mechanosensitive voltage-gated sodium and calcium channels to the mechanogated ion channels, such as the two-pore domain potassium channels K2P (TREK-1) and nonselective cation channels from the transient receptor potential family. The recently discovered Piezo channels are increasingly recognized as significant contributors to cellular mechanosensitivity. Piezo1 and Piezo2 are nonselective cationic ion channels that are directly activated by mechanical forces and have well-defined biophysical and pharmacologic properties. The role of Piezo channels in the GI epithelium is currently under investigation and their role in the smooth muscle syncytium and enteric neurons is still not known. In this review, we outline the current state of knowledge on mechanosensitive ion channels in the GI tract, with a focus on the known and potential functions of the Piezo channels. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. A Perspective on the MIMO Wiretap Channel

    KAUST Repository

    Oggier, Frederique

    2015-10-01

    A wiretap channel is a communication channel between a transmitter Alice and a legitimate receiver Bob, in the presence of an eavesdropper Eve. The goal of communication is to achieve reliability between Alice and Bob, but also confidentiality despite Eve’s presence. Wiretap channels are declined in all kinds of flavors, depending on the underlying channels used by the three players: discrete memoryless channels, additive Gaussian noise channels, or fading channels, to name a few. In this survey, we focus on the case where the three players use multiple-antenna channels with Gaussian noise to communicate. After summarizing known results for multiple-input–multiple-output (MIMO) channels, both in terms of achievable reliable data rate (capacity) and code design, we introduce the MIMO wiretap channel. We then state the MIMO wiretap capacity, summarize the idea of the proof(s) behind this result, and comment on the insights given by the proofs on the physical meaning of the secrecy capacity. We finally discuss design criteria for MIMO wiretap codes.

  2. Sediment sorting at a side channel bifurcation

    Science.gov (United States)

    van Denderen, Pepijn; Schielen, Ralph; Hulscher, Suzanne

    2017-04-01

    Side channels have been constructed to reduce the flood risk and to increase the ecological value of the river. In various Dutch side channels large aggradation in these channels occurred after construction. Measurements show that the grain size of the deposited sediment in the side channel is smaller than the grain size found on the bed of the main channel. This suggest that sorting occurs at the bifurcation of the side channel. The objective is to reproduce with a 2D morphological model the fining of the bed in the side channel and to study the effect of the sediment sorting on morphodynamic development of the side channel. We use a 2D Delft3D model with two sediment fractions. The first fraction corresponds with the grain size that can be found on the bed of the main channel and the second fraction corresponds with the grain size found in the side channel. With the numerical model we compute several side channel configurations in which we vary the length and the width of the side channel, and the curvature of the upstream channel. From these computations we can derive the equilibrium state and the time scale of the morphodynamic development of the side channel. Preliminary results show that even when a simple sediment transport relation is used, like Engelund & Hansen, more fine sediment enters the side channel than coarse sediment. This is as expected, and is probably related to the bed slope effects which are a function of the Shields parameter. It is expected that by adding a sill at the entrance of the side channel the slope effect increases. This might reduce the amount of coarse sediment which enters the side channel even more. It is unclear whether the model used is able to reproduce the effect of such a sill correctly as modelling a sill and reproducing the correct hydrodynamic and morphodynamic behaviour is not straightforward in a 2D model. Acknowledgements: This research is funded by STW, part of the Dutch Organization for Scientific Research under

  3. Performance Analysis of Iterative Channel Estimation and Multiuser Detection in Multipath DS-CDMA Channels

    Science.gov (United States)

    Li, Husheng; Betz, Sharon M.; Poor, H. Vincent

    2007-05-01

    This paper examines the performance of decision feedback based iterative channel estimation and multiuser detection in channel coded aperiodic DS-CDMA systems operating over multipath fading channels. First, explicit expressions describing the performance of channel estimation and parallel interference cancellation based multiuser detection are developed. These results are then combined to characterize the evolution of the performance of a system that iterates among channel estimation, multiuser detection and channel decoding. Sufficient conditions for convergence of this system to a unique fixed point are developed.

  4. Roughness coefficients for stream channels in Arizona

    Science.gov (United States)

    Aldridge, B.N.; Garrett, J.M.

    1973-01-01

    When water flows in an open channel, energy is lost through friction along the banks and bed of the channel and through turbulence within the channel. The amount of energy lost is governed by channel roughness, which is expressed in terms of a roughness coefficient. An evaluation of the roughness coefficient is necessary in many hydraulic computations that involve flow in an open channel. Owing to the lack of satisfactory quantitative procedure, the ability of evaluate roughness coefficients can be developed only through experience; however, a basic knowledge of the methods used to assign the coefficients and the factors affecting them will be a great help. One of the most commonly used equations in open-channel hydraulics is that of Manning. The Manning equation is       1.486

  5. KATP Channels in the Cardiovascular System.

    Science.gov (United States)

    Foster, Monique N; Coetzee, William A

    2016-01-01

    KATP channels are integral to the functions of many cells and tissues. The use of electrophysiological methods has allowed for a detailed characterization of KATP channels in terms of their biophysical properties, nucleotide sensitivities, and modification by pharmacological compounds. However, even though they were first described almost 25 years ago (Noma 1983, Trube and Hescheler 1984), the physiological and pathophysiological roles of these channels, and their regulation by complex biological systems, are only now emerging for many tissues. Even in tissues where their roles have been best defined, there are still many unanswered questions. This review aims to summarize the properties, molecular composition, and pharmacology of KATP channels in various cardiovascular components (atria, specialized conduction system, ventricles, smooth muscle, endothelium, and mitochondria). We will summarize the lessons learned from available genetic mouse models and address the known roles of KATP channels in cardiovascular pathologies and how genetic variation in KATP channel genes contribute to human disease. Copyright © 2016 the American Physiological Society.

  6. Pore size matters for potassium channel conductance

    Science.gov (United States)

    Moldenhauer, Hans; Pincuntureo, Matías

    2016-01-01

    Ion channels are membrane proteins that mediate efficient ion transport across the hydrophobic core of cell membranes, an unlikely process in their absence. K+ channels discriminate K+ over cations with similar radii with extraordinary selectivity and display a wide diversity of ion transport rates, covering differences of two orders of magnitude in unitary conductance. The pore domains of large- and small-conductance K+ channels share a general architectural design comprising a conserved narrow selectivity filter, which forms intimate interactions with permeant ions, flanked by two wider vestibules toward the internal and external openings. In large-conductance K+ channels, the inner vestibule is wide, whereas in small-conductance channels it is narrow. Here we raise the idea that the physical dimensions of the hydrophobic internal vestibule limit ion transport in K+ channels, accounting for their diversity in unitary conductance. PMID:27619418

  7. Structure of conducting channel of lightning

    International Nuclear Information System (INIS)

    Alanakyan, Yu. R.

    2013-01-01

    The spatial distribution of the plasma density in a lightning channel is studied theoretically. It is shown that the electric-field double layer is formed at the channel boundary. In this case, the electron temperature changes abruptly and ions are accelerated by the electric field of the double layer. The ion momentum flux density is close to the surrounding gas pressure. Cleaning of the channel from heavy particles occurs in particle-exchange processes between the plasma channel and the surrounding air. Hydrogen ions are accumulated inside the expanding channel from the surrounding air, which is enriched by hydrogen-contained molecules. In this case, the plasma channel is unstable and splits to a chain of equidistant bunches of plasma. The hydrogen-enrich bunches burn diffusely after recombination exhibiting the bead lightning behavior

  8. Bywalled plasma formation in vacuum prolonged channels

    International Nuclear Information System (INIS)

    Korenev, S.A.; Rubin, N.B.

    1982-01-01

    To produce homogeneous along the channel length plasma the application of incomplete rate-in surface dielectric discharge for generating the bywalled plasma in prolonged cylindrical channels at a pressure of the residual gas of P approximately 10 -5 Torr is proposed. Experimental set-up consisted of a pulse voltage generator and a plasma channel. The plasma channel was a coaxial system of three tubes inserted into each other. The first outer tube is made of a stainless steel, the second - of a dielectric material, the third - of smallsized stainless steel greed. It is demonstrated that the plasma being formed in the process is sufficiently homogeneous by concentration of the components, by the channel length and azimuth. The length of the experimental channel under investigation was 1.6 m, its diameter amounted 0.05 m. The maximum concentration of electron component was 10 17 m -3

  9. Analytical admittance characterization of high mobility channel

    Energy Technology Data Exchange (ETDEWEB)

    Mammeri, A. M.; Mahi, F. Z., E-mail: fati-zo-mahi2002@yahoo.fr [Institute of Science and Technology, University of Bechar (Algeria); Varani, L. [Institute of Electronics of the South (IES - CNRS UMR 5214), University of Montpellier (France)

    2015-03-30

    In this contribution, we investigate the small-signal admittance of the high electron mobility transistors field-effect channels under a continuation branching of the current between channel and gate by using an analytical model. The analytical approach takes into account the linearization of the 2D Poisson equation and the drift current along the channel. The analytical equations discuss the frequency dependence of the admittance at source and drain terminals on the geometrical transistor parameters.

  10. Control system design for concrete irrigation channels

    OpenAIRE

    Strecker, Timm; Aamo, Ole Morten; Cantoni, Michael

    2017-01-01

    Concrete channels find use at the periphery of irrigation networks, for expansion and to replace small earthen channels given the relative ease of maintenance and elimination of seepage losses. In design, it is important to account for control system performance when dimensioning the channel infrastructure. In this paper, the design of a distributed controller is investigated in terms managing water-levels, and thereby the depth profile (i.e., amount of concrete) needed to support peak flow l...

  11. Electronic trade effect of marketing channels

    OpenAIRE

    Lovreta Stipe; Stojković Dragan

    2009-01-01

    E-commerce has caused many significant changes in marketing channels. Consumers had obtained multiple benefits from e-commerce. In addition, it has increased the level of competition in marketing channels. However, the focus of this paper is multichannel strategy and integration of physical (store) and electronic marketing channels. E-commerce has induced dynamic development of multichannel strategy. This strategy has evolved as a consequence of multichannel consumer orientation. In developed...

  12. Universal communication part II: channels with memory

    OpenAIRE

    Lomnitz, Yuval; Feder, Meir

    2012-01-01

    Consider communication over a channel whose probabilistic model is completely unknown vector-wise and is not assumed to be stationary. Communication over such channels is challenging because knowing the past does not indicate anything about the future. The existence of reliable feedback and common randomness is assumed. In a previous paper it was shown that the Shannon capacity cannot be attained, in general, if the channel is not known. An alternative notion of "capacity" was defined, as the...

  13. Stability analysis for downflow in heated channels

    International Nuclear Information System (INIS)

    Sampaio, P.A.B. de.

    1985-01-01

    Stability and flow distribution are analysed for downflow in heated channels. It is shown that at low flow rates instabilities associated with the buoyancy forces may appear. A computer code in FORTRAN language to determine downflow distribution among n heated channels is presented. The model used to calculate downflow distribution and the onset of instability is compared with experiments performed in a test section with two parallel channels. (Author) [pt

  14. Export channel pricing management for integrated solutions

    OpenAIRE

    Roine, Henna; Sainio, Liisa-Maija; Saarenketo, Sami

    2012-01-01

    This article studies systems integrators' export channel pricing management for integrated solutions. We find support from our empirical case study for the notion that a systems integrator's export channel pricing strategy is multidimensional and dependent on international pricing environment and partner characteristics and that export partnerships have unique implications on a systems integrator's pricing process. The results show that giving up pricing control in export channel context may ...

  15. Pharmaceutical Distribution Market Channels in Poland

    Directory of Open Access Journals (Sweden)

    Agnieszka Woś

    2009-09-01

    Full Text Available Distribution on the pharmaceutical market in Poland is interesting and the most difficult sphere to manage. Numerous varied and specialized companies operating on the market cause that the processes of choosing middlemen in distribution channels are very complex. The hereby article presents the role and location of the companies operating within distribution channels on the pharmaceutical market. It draws attention to the development of non-pharmacy and non-wholesale sales channels.

  16. Quantum privacy and Schur product channels

    Science.gov (United States)

    Levick, Jeremy; Kribs, David W.; Pereira, Rajesh

    2017-12-01

    We investigate the quantum privacy properties of an important class of quantum channels, by making use of a connection with Schur product matrix operations and associated correlation matrix structures. For channels implemented by mutually commuting unitaries, which cannot privatise qubits encoded directly into subspaces, we nevertheless identify private algebras and subsystems that can be privatised by the channels. We also obtain further results by combining our analysis with tools from the theory of quasi-orthogonal operator algebras and graph theory.

  17. Channeling crystals for positron production

    International Nuclear Information System (INIS)

    Decker, F.J.

    1991-05-01

    Particles traversing at small angles along a single crystal axis experience a collective scattering force of many crystal atoms. The enormous fields can trap the particles along an axis or plane, called channeling. High energy electrons are attracted by the positive nuclei and therefore produce strongly enhanced so called coherent bremsstrahlung and pair production. These effects could be used in a positron production target: A single tungsten crystal is oriented to the incident electron beam within 1 mrad. At 28 GeV/c the effective radiation length is with 0.9 mm about one quarter of the amorphous material. So the target length can be shorter, which yields a higher conversion coefficient and a lower emittance of the positron beam. This makes single crystals very interesting for positron production targets. 18 refs., 2 figs

  18. Fuel channel closure and adapter

    International Nuclear Information System (INIS)

    Cashen, W.S.

    1985-01-01

    This invention provides a mechanical closure/actuating ram combination particularly suited for use in sealing the ends of the pressure tubes when a CANDU-type reactor is refueled. It provides a cluster that may be inserted into a fuel channel end fitting to provide at least partial closing off of a pressure tube while permitting the disengagement of the fueling machine and its withdrawal from the closure for other purposes. The invention also provides a ram/closure combination wherein the application of loading force to a deformable sealing disk is regulated by a massive load bar component forming part of the fueling machine and being therefore accessible for maintenance or replacement

  19. Axial channeling in electron diffraction

    International Nuclear Information System (INIS)

    Ichimiya, A.; Lehmpfuhl, G.

    1978-01-01

    Kossel patterns from Silicon and Niobium were obtained with a convergent electron beam. An intensity maximum in the direction of the zone axes [001] and [111] of Nb was interpreted as axial channeling. The intensity distribution in Kossel patterns was calculated by means of the Bloch wave picture of the dynamical theory of electron diffraction. Particularly zone axis patterns were calculated for different substance-energy combinations and they were compared with experimental observations. The intensity distribution in the calculated Kossel patterns was very sensitive to the model of absorption and it was found that a treatment of the absorption close to the model of Humphreys and Hirsch [Phil. Mag. 18, 115 (1968)] gave the best agreement with the experimental observations. Furthermore it is shown which Bloch waves are important for the intensity distribution in the Kossel patterns, how they are absorbed and how they change with energy. (orig.) [de

  20. [Synopsis about the hypothesis of "information channel" of channel-collateral system].

    Science.gov (United States)

    Chang, Xi-Lang

    2008-10-01

    The author of the present paper founded a theorem about the "incompleteness of single channel structure" (nerve, blood vessel, lymphatic, interspace, aperture, etc.) through quantitative and qualitative analysis about the economic information channel in the human body, which eliminates the probability of single channel structure in the information channel of channel (meridian)-collateral system. After comprehensive analysis on the current researches, the author puts forward a neodoxy, i.e., the body "information channel" structure of the channel-collateral system, mainly follows the distribution regularity of systemic statistics, and is not a single specific entity; various layers of the information channel in the main stems of the channel-collaterals are composed of optimized structure tissues. Hence, the structure of this information channel of channel-collateral system is an overall-optimized, sequential and compatible systemic structure. From this neodoxy, the author brings forward a working principle of channel-collaterals, which is supported theoretically by bio-auxology. The longitudinal distribution of the main stems of meridian-collaterals is considered to result from that in the process of the animal evolution, in the animals moving forward, the microscopic complicated movement of intracorporeal information and energy molecules is related to the forward macroscopic and non-uniform movement of organism in trans-measure. Its impulse and kinetic momentum forms a main vector in the longitudinal direction of the body (the direction of the main stem of channel-collaterals). In order to adapt to and utilize natural regularities, the main stems of the channel-collaterals gradually differentiate and evolve in the living organism, forming a whole system. The "hypothesis of biological origin of channel-collateral system" and "that of information channel of the channel-collaterals in the body" constitute a relatively complete theoretical system framework.

  1. Customer Engagement Tool (Multi Channel Communication)

    Data.gov (United States)

    Social Security Administration — Add new infrastructure within SSA's Enterprise Architecture to allow interactions over multiple, yet to be defined, channels. Possibilities include: Provide a portal...

  2. Channeling ion implantation through palladium films

    International Nuclear Information System (INIS)

    Ishiwara, H.; Furukawa, S.

    1975-01-01

    The possibility of channeling ion implantation into semiconductors through polycrystalline metallic layers is studied. Minimum values and standard deviations of channeling angular yield in polycrystalline Pd 2 Si layers formed on Si have been measured by protons and 4 He, and 14 N ion backscattering and channeling measurements. Depth distributions of the spread of crystallite orientations and scattering centers such as lattice defects have been separately derived by using the above two quantities. It has been concluded that the channeling-ion-implantation technique will become a practical one by using the parallel scanning system

  3. Indoor MIMO Channel Measurement and Modeling

    DEFF Research Database (Denmark)

    Nielsen, Jesper Ødum; Andersen, Jørgen Bach

    2005-01-01

    Forming accurate models of the multiple input multiple output (MIMO) channel is essential both for simulation as well as understanding of the basic properties of the channel. This paper investigates different known models using measurements obtained with a 16x32 MIMO channel sounder for the 5.8GHz...... band. The measurements were carried out in various indoor scenarios including both temporal and spatial aspects of channel changes. The models considered include the so-called Kronecker model, a model proposed by Weichselberger et. al., and a model involving the full covariance matrix, the most...

  4. Achromatic Cooling Channel with Li Lenses

    Energy Technology Data Exchange (ETDEWEB)

    Balbekov, V. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2002-04-29

    A linear cooling channel with Li lenses, solenoids, and 201 MHz RF cavities is considered. A special lattice design is used to minimize chromatic aberrations by suppression of several betatron resonances. Transverse emittance of muon beam decreases from 2 mm to 0.5 mm at the channel of about 110 m length. Longitudinal heating is modest, therefore transmission of the channel is rather high: 96% without decay and 90% with decay. Minimal beam emittance achievable by similar channel estimated as about 0.25 mm at surface field of Li lenses 10 T.

  5. Optimal processing of reversible quantum channels

    Energy Technology Data Exchange (ETDEWEB)

    Bisio, Alessandro, E-mail: alessandro.bisio@unipv.it [QUIT Group, Dipartimento di Fisica, INFN Sezione di Pavia, via Bassi 6, 27100 Pavia (Italy); D' Ariano, Giacomo Mauro; Perinotti, Paolo [QUIT Group, Dipartimento di Fisica, INFN Sezione di Pavia, via Bassi 6, 27100 Pavia (Italy); Sedlák, Michal [Department of Optics, Palacký University, 17. Listopadu 1192/12, CZ-771 46 Olomouc (Czech Republic); Institute of Physics, Slovak Academy of Sciences, Dúbravská Cesta 9, 845 11 Bratislava (Slovakia)

    2014-05-01

    We consider the general problem of the optimal transformation of N uses of (possibly different) unitary channels to a single use of another unitary channel in any finite dimension. We show how the optimal transformation can be fully parallelized, consisting in a preprocessing channel followed by a parallel action of all the N unitaries and a final postprocessing channel. Our techniques allow to achieve an exponential reduction in the number of the free parameters of the optimization problem making it amenable to an efficient numerical treatment. Finally, we apply our general results to find the analytical solution for special cases of interest like the cloning of qubit phase gates.

  6. Almost all quantum channels are equidistant

    Science.gov (United States)

    Nechita, Ion; Puchała, Zbigniew; Pawela, Łukasz; Życzkowski, Karol

    2018-05-01

    In this work, we analyze properties of generic quantum channels in the case of large system size. We use random matrix theory and free probability to show that the distance between two independent random channels converges to a constant value as the dimension of the system grows larger. As a measure of the distance we use the diamond norm. In the case of a flat Hilbert-Schmidt distribution on quantum channels, we obtain that the distance converges to 1/2 +2/π , giving also an estimate for the maximum success probability for distinguishing the channels. We also consider the problem of distinguishing two random unitary rotations.

  7. Secure Broadcasting with Uncertain Channel State Information

    KAUST Repository

    Hyadi, Amal; Rezki, Zouheir; Khisti, Ashish; Alouini, Mohamed-Slim

    2017-01-01

    -main CSI are also analyzed. Analytical derivations and numerical results are presented to illustrate the obtained expressions for the case of independent and identically distributed Rayleigh fading channels.

  8. Secure Broadcasting with Uncertain Channel State Information

    KAUST Repository

    Hyadi, Amal; Rezki, Zouheir; Khisti, Ashish; Alouini, Mohamed-Slim

    2016-01-01

    -main CSI are also analyzed. Analytical derivations and numerical results are presented to illustrate the obtained expressions for the case of independent and identically distributed Rayleigh fading channels.

  9. Channel Responses and Hydromodification in Southern California

    Science.gov (United States)

    Hawley, R. J.; Dust, D. W.; Bledsoe, B. P.

    2007-12-01

    Hydromodification (changes in watershed hydrologic characteristics, and the resulting hydraulics and channel forms due to urbanization) is ubiquitous in Southern California. In this region, the effects of hydromodification are driven and compounded by the arid/semiarid climate, high relief, erodible soils, high urbanization rates, and relatively low frequency of retention/detention. We conducted a preliminary survey of over 50 stream reaches along a gradient from least disturbed to fully urbanized. All stages of the Channel Evolution Model (CEM) of Schumm et al. (1984) were observed, from stable to degrading, widening, aggrading, and quasi-equilibrium channels. Several sites have CEM stages II through V in close proximity due to headcutting, hardpoints, and infrastructure. We also observed channels in undeveloped watersheds impacted by downstream urbanization via headcutting. A range of intervention measures was observed, with the frequent evolutionary endpoint as a concrete engineered flood control channel. We also observed multiple channel evolution sequences that deviate from the CEM for single-thread, incising channels. An alternative channel response, particularly on smaller urbanized streams is a stabilized, vegetation encroached low-flow channel with regular baseflow supplied by residential irrigation runoff. The limited cases of unimpacted streams that remain tend to be high gradient, high energy systems that are naturally proximate to the transition between braided and meandering form for a given sediment size.

  10. Flow and sediment transport across oblique channels

    DEFF Research Database (Denmark)

    Hjelmager Jensen, Jacob; Madsen, Erik Østergaard; Fredsøe, Jørgen

    1998-01-01

    A 3D numerical investigation of flow across channels aligned obliquely to the main flow direction has been conducted. The applied numerical model solves the Reynolds-averaged Navier-Stokes equations using the k-ε model for turbulence closure on a curvilinear grid. Three momentum equations...... are solved, but the computational domain is 2D due to a uniformity along the channel alignment. Two important flow features arise when the flow crosses the channel: (i) the flow will be refracted in the direction of the channel alignment. This may be described by a depth-averaged model. (ii) due to shear...

  11. On the domestic fuel channel for BWR

    International Nuclear Information System (INIS)

    Fukada, Hiroshi

    1979-01-01

    Kobe Steel Ltd. started the domestic manufacture of fuel channel boxes for BWRs in 1967, and entered the actual production stage four years after that. Since 1976, the mass production system was adopted with the increase of the demand. The requirements about the surface contamination and the dimensional accuracy over whole length are very strict in the fuel channel boxes, moreover, special consideration must be given so as to prevent the deformation in use. The unique working methods such as electron beam welding, high temperature press forming and so on are employed in Kobe Steel Ltd. to satisfy such strict requirements, therefore the quality of the produced fuel channel boxes is superior to imported ones. At present, the fuel channel boxes domestically made by Kobe Steel Ltd. are used for almost all BWRs in Japan. The functions of fuel channel boxes are to flow boiling coolant uniformly upward, to guide control rods, and to increase the rigidity of fuel assembly. The fuel channel boxes are the square tubes of zircaloy 4 of 134.06 mm inside width, 2.03 mm thickness, and 4118 or 4239 mm length. The progress of the development and the features of the fuel channel boxes and the manufacturing processes are described. Zircaloy plates are formed into channels, and two channels are electron beam-welded after the edge preparation, to make a box. Ultrasonic examination and stress relief treatment are applied, and clips and spacers are welded. (Kako, I.)

  12. Dimension measuring method for channel box

    International Nuclear Information System (INIS)

    Jo, Hiroto.

    1995-01-01

    The device of the present invention concerns detection of a channel box for spent fuel assemblies of a BWR type reactor, which measures a cross sectional shape and dimension of the channel box to check deformation amount such as expansion. That is, a customary fuel exchanger and a dimension measuring device are used. The lower end of the channel box is measured by a distance sensor of the dimension measuring device when it is aligned with a position of the distance sensor. The channel box is lowered at the same time while detecting axial position data of the fuel exchanger. The position of the channel box in an axial direction is detected based on axial position data of the fuel exchanger. The lower end of the channel box can accurately be recognized by the detection of both of them. Subsequent deformation measurement for the channel box at accurate axial positions is enabled. In addition, since the axial position data of the fuel exchanger per se are detected, an axial profile of the channel box can be measured even if a lifting speed of the channel box is varied on every region. (I.S.)

  13. Measuring Balance Across Multiple Radar Receiver Channels.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W.; Bickel, Douglas L.

    2018-03-01

    When radar receivers employ multiple channels, the general intent is for the receive channels to be as alike as possible, if not as ideal as possible. This is usually done via prudent hardware design, supplemented by system calibration. Towards this end, we require a quality metric for ascertaining the goodness of a radar channel, and the degree of match to sibling channels. We propose a relevant and useable metric to do just that. Acknowledgements This report was the result of an unfunded research and development activity.

  14. Channeling and related crystal effects

    International Nuclear Information System (INIS)

    Uggerhoj, Erik

    1995-01-01

    Channeling, the interaction of particles with oriented crystals, has been applied in a wide variety of scientific and technological areas. A workshop at Aarhus, Denmark, this summer highlighted progress and future directions. Radiation emission has been explored and linked to coherent bremsstrahlung and other oriented crystal radiations. Dramatic effects have been found for ultra-relativistic electrons with Lorentz factors of 105 6. Single crystals are unique for investigations of quantum electrodynamics in strong external fields because probabilities for processes in axial/ planar fields are determined by the magnitude of these fields in the particle rest frame. Erik Uggerhoj of Aarhus reported on an extensive series of experiments concerning radiation emission, pair production, and shower formation carried out at CERN by the NA43 collaboration. As Vladimir Baier of Novosibirsk and Yuri Kononets of Kurchatov noted, theoretical treatment of these interconnected radiation distributions is challenging and much work needs to be done. In general, the agreement with the CERN experiments is good, but many areas like polarization phenomena and particle production need investigation. Prominent among high energy applications is extraction from accelerators. At the workshop, Alexei Asseev reported on beam extraction using a bent crystal at Serpukhov. Konrad Elsener and Jukka Klem reviewed recent CERN SPS studies driven by the possibility of using crystals for extraction of LHC beams. Thornton Murphy of Fermilab announced a step in that direction, with a demonstration this summer of extraction from the Tevatron at 900 GeV. Bent crystal channeling is also used for handling extracted high energy beams. Niels Doble presented a beautiful example of a beam for the CERN NA48 CP-violation experiment. Yuri Chesnokov reported that beams had been deflected through angles up to 150 milliradians at Serpukhov

  15. EPICS channel access using websocket

    International Nuclear Information System (INIS)

    Uchiyama, A.; Furukawa, K.; Higurashi, Y.

    2012-01-01

    Web technology is useful as a means of widely disseminating accelerator and beam status information. For this purpose, WebOPI was implemented by SNS as a web-based system using Ajax (asynchronous JavaScript and XML) with EPICS. On the other hand, it is often necessary to control the accelerator from different locations as well as the central control room during beam operation and maintenance. However, it is not realistic to replace the GUI-based operator interface (OPI) with a Web-based system using Ajax technology because of interactive performance issue. Therefore, as a next generation OPI over the web using EPICS Channel Access (CA), we developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force (IETF) for Web-based systems. WebSocket is a web technology that provides bidirectional, full-duplex communication channels over a single TCP connection. By utilizing Node.js and the WebSocket access library called Socket.IO, a WebSocket server was implemented. Node.js is a server-side JavaScript language built on the Google V8 JavaScript Engine. In order to construct the WebSocket server as an EPICS CA client, an add-on for Node.js was developed in C/C++ using the EPICS CA library, which is included in the EPICS base. As a result, for accelerator operation, Web-based client systems became available not only in the central control room but also with various types of equipment. (author)

  16. Improvement of Metroliner Telephone Channel Capacity and Modeling of Telephone Channel Demands

    Science.gov (United States)

    1972-03-01

    The channel capacity of the present Metroliner telephone system is analyzed and methods are proposed to increase that capacity without increasing the overall bandwidth. To determine the number of channels required, calculations have been carried out ...

  17. An information-guided channel-hopping scheme for block-fading channels with estimation errors

    KAUST Repository

    Yang, Yuli

    2010-12-01

    Information-guided channel-hopping technique employing multiple transmit antennas was previously proposed for supporting high data rate transmission over fading channels. This scheme achieves higher data rates than some mature schemes, such as the well-known cyclic transmit antenna selection and space-time block coding, by exploiting the independence character of multiple channels, which effectively results in having an additional information transmitting channel. Moreover, maximum likelihood decoding may be performed by simply decoupling the signals conveyed by the different mapping methods. In this paper, we investigate the achievable spectral efficiency of this scheme in the case of having channel estimation errors, with optimum pilot overhead for minimum meansquare error channel estimation, when transmitting over blockfading channels. Our numerical results further substantiate the robustness of the presented scheme, even with imperfect channel state information. ©2010 IEEE.

  18. Channel characteristics and coordination in three-echelon dual-channel supply chain

    Science.gov (United States)

    Saha, Subrata

    2016-02-01

    We explore the impact of channel structure on the manufacturer, the distributer, the retailer and the entire supply chain by considering three different channel structures in radiance of with and without coordination. These structures include a traditional retail channel and two manufacturer direct channels with and without consistent pricing. By comparing the performance of the manufacturer, the distributer and the retailer, and the entire supply chain in three different supply chain structures, it is established analytically that, under some conditions, a dual channel can outperform a single retail channel; as a consequence, a coordination mechanism is developed that not only coordinates the dual channel but also outperforms the non-cooperative single retail channel. All the analytical results are further analysed through numerical examples.

  19. An approach to implement virtual channels for flowing magnetic beads

    International Nuclear Information System (INIS)

    Tang, Shih-Hao; Chiang, Hung-Wei; Hsieh, Min-Chien; Chang, Yen-Di; Yeh, Po-Fan; Tsai, Jui-che; Shieh, Wung-Yang

    2014-01-01

    This work demonstrates the feasibility of a novel microfluidic system with virtual channels formed by ‘walls’ of magnetic fields, including collecting channels, transporting channels and function channels. The channels are defined by the nickel patterns. With its own ferromagnetism, nickel can be magnetized using an external magnetic field; the nickel structures then generate magnetic fields that can either guide or trap magnetic beads. A glass substrate is sandwiched between the liquid containing magnetic beads and the chip with nickel structures, preventing the liquid from directly contacting the nickel. In this work, collecting channels, transporting channels and function channels are displayed sequentially. In the collecting channel portion, channels with different shapes are compared. Next, in the transporting channel portion we demonstrate I-, S- and Y-shaped channels can steer magnetic beads smoothly. Finally, in the function channel portion, a switchable trapping channel implemented with a bistable mechanism performs the passing and blocking of a magnetic bead. (paper)

  20. Differential Effects of TRPA and TRPV Channels on Behaviors of

    Directory of Open Access Journals (Sweden)

    Jennifer Thies

    2016-01-01

    Full Text Available TRPA and TRPV ion channels are members of the transient receptor potential (TRP cation channel superfamily, which mediates various sensory transductions. In Caenorhabditis elegans , the TRPV channels are known to affect chemosensation, while the TRPA-1 channel is associated with thermosensation and mechanosensation. We examined thermosensation, chemosensation, and osmosensation in strains lacking TRPA-1 or TRPV channels. We found that TRPV channel knockout worms exhibited similar behavioral deficits associated with thermotaxis as the TRPA-1 channel knockout, suggesting a dual role for TRPV channels. In contrast, chemosensation responses, assessed by both avoidance reversal behavior and NaCl osmosensation, were dependent on TRPV channels but seemed independent of TRPA-1 channel. Our findings suggest that, in addition to TRPA-1 channel, TRPV channels are necessary for thermotaxis and may activate, or modulate, the function of TRPA-1 channels. In contrast, TRPA-1 channels do not have a dual responsibility, as they have no functional role in odorant avoidance or osmosensation.

  1. XPM-induced degradation of multilevel phase modulated channel caused by neighboring NRZ modulated channels

    DEFF Research Database (Denmark)

    Jensen, Jesper Bevensee; Schiellerup, G.; Peucheret, Christophe

    2008-01-01

    The impact of XPM from NRZ modulated channels on an 8-level phase modulated channel in a WDM system was investigated. Requirements on launch power are found. 400 km transmission was achieved with negligible penalty.......The impact of XPM from NRZ modulated channels on an 8-level phase modulated channel in a WDM system was investigated. Requirements on launch power are found. 400 km transmission was achieved with negligible penalty....

  2. On the Capacity of the Dirty Paper Channel with Fast Fading and Discrete Channel States

    OpenAIRE

    Rini, Stefano; Shitz, Shlomo Shamai

    2016-01-01

    The "writing dirty paper" capacity result crucially dependents on the perfect channel knowledge at the transmitter as the presence of even a small uncertainty in the channel realization gravely hampers the ability of the transmitter to pre-code its transmission against the channel state. This is particularly disappointing as it implies that interference pre-coding in practical systems is effective only when the channel estimates at the users have very high precision, a condition which is gene...

  3. A new simple model for composite fading channels: Second order statistics and channel capacity

    KAUST Repository

    Yilmaz, Ferkan; Alouini, Mohamed-Slim

    2010-01-01

    In this paper, we introduce the most general composite fading distribution to model the envelope and the power of the received signal in such fading channels as millimeter wave (60 GHz or above) fading channels and free-space optical channels, which

  4. Multi-channel service retailing: The effects of channel performance satisfaction on behavioral intentions.

    NARCIS (Netherlands)

    Birgelen, van M.; Jong, de A.; Ruyter, de J.C.

    2006-01-01

    Abstract The number of channels that retailers can use interchangeably to provide customer service has increased. We report on a study of clients of a large retail bank that investigates the channel performance satisfaction–behavioral intentions relationship when the traditional service channel

  5. Optimising the Quality of Experience during Channel Zapping : The Impact of Advertisements during Channel Zapping

    NARCIS (Netherlands)

    Kooij, R.E.; Klos, V.B.; Godana, B.E.; Nicolai, F.P.; Ahmed, O.K.

    2009-01-01

    Nowadays various digital television services are available. However, the user of these services experiences longer delays than the traditional analog TV while switching from channel to channel. The digital TV operator usually displays a black screen with the channel number during zapping. However,

  6. The sedimentary record of submarine channel morphodynamics

    NARCIS (Netherlands)

    de Leeuw, J.

    2017-01-01

    Submarine channels are ubiquitous on the ocean floor and are considered to be the equivalent of rivers on land. These channels are created by turbidity currents, which originate from the continental margins and which can transport sediment for thousands of kilometres into the oceans. The aim of this

  7. Steady turbulent flow in curved rectangular channels

    NARCIS (Netherlands)

    De Vriend, H.J.

    1979-01-01

    After the study of fully developed and developing steady laminar flow in curved channels of shallow rectangular wet cross-section (see earlier reports in this series), steady turbulent flow in such channels is investigated as a next step towards a mathematical model of the flow in shallow river

  8. 47 CFR 101.1405 - Channeling plan.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Channeling plan. 101.1405 Section 101.1405 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... Channeling plan. Each license shall have one spectrum block of 500 megahertz per geographic area that can be...

  9. Privacy of a lossy bosonic memory channel

    Energy Technology Data Exchange (ETDEWEB)

    Ruggeri, Giovanna [Dipartimento di Fisica, Universita di Lecce, I-73100 Lecce (Italy)]. E-mail: ruggeri@le.infn.it; Mancini, Stefano [Dipartimento di Fisica, Universita di Camerino, I-62032 Camerino (Italy)]. E-mail: stefano.mancini@unicam.it

    2007-03-12

    We study the security of the information transmission between two honest parties realized through a lossy bosonic memory channel when losses are captured by a dishonest party. We then show that entangled inputs can enhance the private information of such a channel, which however does never overcome that of unentangled inputs in absence of memory.

  10. Forbidden Channels and SIMP Dark Matter

    OpenAIRE

    Choi Soo-Min; Kang Yoo-Jin; Lee Hyun Min

    2018-01-01

    In this review, we focus on dark matter production from thermal freeze-out with forbidden channels and SIMP processes. We show that forbidden channels can be dominant to produce dark matter depending on the dark photon and / or dark Higgs mass compared to SIMP.

  11. Hydrodynamic blood plasma separation in microfluidic channels

    DEFF Research Database (Denmark)

    Jouvet, Lionel

    2010-01-01

    The separation of red blood cells from plasma flowing in microchannels is possible by biophysical effects such as the Zweifach–Fung bifurcation law. In the present study, daughter channels are placed alongside a main channel such that cells and plasma are collected separately. The device is aimed...

  12. Measuring vibrations in fuel channels CNE

    International Nuclear Information System (INIS)

    Martín Ghiselli, A.; Fiori, J.; Sacchi, M.; Villabrille, G.

    2013-01-01

    This paper present a description of implementation and execution of vibration measurements made at the request of NUCLEOELECTRICA ARGENTINA S.A. on the ends of the reactor fuel channels of Embalse Nuclear Power Plant to explore possible differences between the dynamic behavior of empty fuel channel and with full charge of fuel elements inside. (author)

  13. Additivity properties of a Gaussian channel

    International Nuclear Information System (INIS)

    Giovannetti, Vittorio; Lloyd, Seth

    2004-01-01

    The Amosov-Holevo-Werner conjecture implies the additivity of the minimum Renyi entropies at the output of a channel. The conjecture is proven true for all Renyi entropies of integer order greater than two in a class of Gaussian bosonic channel where the input signal is randomly displaced or where it is coupled linearly to an external environment

  14. Transportation channels calculation method in MATLAB

    International Nuclear Information System (INIS)

    Averyanov, G.P.; Budkin, V.A.; Dmitrieva, V.V.; Osadchuk, I.O.; Bashmakov, Yu.A.

    2014-01-01

    Output devices and charged particles transport channels are necessary components of any modern particle accelerator. They differ both in sizes and in terms of focusing elements depending on particle accelerator type and its destination. A package of transport line designing codes for magnet optical channels in MATLAB environment is presented in this report. Charged particles dynamics in a focusing channel can be studied easily by means of the matrix technique. MATLAB usage is convenient because its information objects are matrixes. MATLAB allows the use the modular principle to build the software package. Program blocks are small in size and easy to use. They can be executed separately or commonly. A set of codes has a user-friendly interface. Transport channel construction consists of focusing lenses (doublets and triplets). The main of the magneto-optical channel parameters are total length and lens position and parameters of the output beam in the phase space (channel acceptance, beam emittance - beam transverse dimensions, particles divergence and image stigmaticity). Choice of the channel operation parameters is based on the conditions for satisfying mutually competing demands. And therefore the channel parameters calculation is carried out by using the search engine optimization techniques.

  15. Adaptive RAC codes employing statistical channel evaluation ...

    African Journals Online (AJOL)

    An adaptive encoding technique using row and column array (RAC) codes employing a different number of parity columns that depends on the channel state is proposed in this paper. The trellises of the proposed adaptive codes and a statistical channel evaluation technique employing these trellises are designed and ...

  16. Flavonoid Regulation of HCN2 Channels*

    Science.gov (United States)

    Carlson, Anne E.; Rosenbaum, Joel C.; Brelidze, Tinatin I.; Klevit, Rachel E.; Zagotta, William N.

    2013-01-01

    The hyperpolarization-activated cyclic nucleotide-modulated (HCN) channels are pacemaker channels whose currents contribute to rhythmic activity in the heart and brain. HCN channels open in response to hyperpolarizing voltages, and the binding of cAMP to their cyclic nucleotide-binding domain (CNBD) facilitates channel opening. Here, we report that, like cAMP, the flavonoid fisetin potentiates HCN2 channel gating. Fisetin sped HCN2 activation and shifted the conductance-voltage relationship to more depolarizing potentials with a half-maximal effective concentration (EC50) of 1.8 μm. When applied together, fisetin and cAMP regulated HCN2 gating in a nonadditive fashion. Fisetin did not potentiate HCN2 channels lacking their CNBD, and two independent fluorescence-based binding assays reported that fisetin bound to the purified CNBD. These data suggest that the CNBD mediates the fisetin potentiation of HCN2 channels. Moreover, binding assays suggest that fisetin and cAMP partially compete for binding to the CNBD. NMR experiments demonstrated that fisetin binds within the cAMP-binding pocket, interacting with some of the same residues as cAMP. Together, these data indicate that fisetin is a partial agonist for HCN2 channels. PMID:24085296

  17. Channel One Online: Advertising Not Educating.

    Science.gov (United States)

    Pasnik, Shelley

    Rather than viewing Channel One's World Wide Web site as an authentic news bureau, as the organization claims, it is better understood as an advertising delivery system. The web site is an attempt to expand Channel One's reach into schools, taking advantage of unsuspecting teachers and students who might fall prey to spurious claims. This paper…

  18. Open channel steam generator feedwater system

    International Nuclear Information System (INIS)

    Kim, R.F.; Min-Hsiung Hu.

    1985-01-01

    A steam generator which utilizes a primary fluid to vaporize a secondary fluid is provided with an open flow channel and elevated discharge nozzle for the introduction of secondary fluid. The discharge nozzle is positioned above a portion of the inlet line such that the secondary fluid passes through a vertical section of inlet line prior to its discharge into the open channel. (author)

  19. Laboratory Experiments on Meandering Meltwater Channels

    Science.gov (United States)

    Fernandez, R.; Berens, J.; Parker, G.; Stark, C. P.

    2017-12-01

    Meandering channels of all scales and flowing over a wide variety of media have common planform patterns. Although the analogy in planform suggests there is a common underlying framework, the constitutive relations driving planform evolution through vertical incision/deposition and lateral migration differ from medium to medium. The driving processes in alluvial and mixed bedrock-alluvial meandering channels have been studied substantially over the last decades. However, this is not the case for meandering channels in other media such as ice or soluble rock. Here we present results from experiments conducted at the Ven Te Chow Hydrosystems Laboratory of the University of Illinois at Urbana-Champaign on meltwater meandering channels. A rivulet is carved into an ice block and water is allowed to flow at a constant discharge. Planform evolution is analyzed with time lapse imaging and complemented with rubber molds of the channel once the experiment is over. These molds give us the full 3D structure of the meandering, including incisional overhang. Vertical incision rates are measured throughout the run by taking elevations along the channel, and these measurements are complemented with analysis from the molds. We show examples of meandering of intense amplitude with deep overhangs. Features resembling scroll bars document cyclically punctuated melting. We report on lateral migration rates, incision rates, sinuosity, channel depths, channel widths, reach averaged velocities, bend wavelengths and amplitudes and compare them to values reported in the literature for alluvial rivers.

  20. Dental enamel cells express functional SOCE channels.

    Science.gov (United States)

    Nurbaeva, Meerim K; Eckstein, Miriam; Concepcion, Axel R; Smith, Charles E; Srikanth, Sonal; Paine, Michael L; Gwack, Yousang; Hubbard, Michael J; Feske, Stefan; Lacruz, Rodrigo S

    2015-10-30

    Dental enamel formation requires large quantities of Ca(2+) yet the mechanisms mediating Ca(2+) dynamics in enamel cells are unclear. Store-operated Ca(2+) entry (SOCE) channels are important Ca(2+) influx mechanisms in many cells. SOCE involves release of Ca(2+) from intracellular pools followed by Ca(2+) entry. The best-characterized SOCE channels are the Ca(2+) release-activated Ca(2+) (CRAC) channels. As patients with mutations in the CRAC channel genes STIM1 and ORAI1 show abnormal enamel mineralization, we hypothesized that CRAC channels might be an important Ca(2+) uptake mechanism in enamel cells. Investigating primary murine enamel cells, we found that key components of CRAC channels (ORAI1, ORAI2, ORAI3, STIM1, STIM2) were expressed and most abundant during the maturation stage of enamel development. Furthermore, inositol 1,4,5-trisphosphate receptor (IP3R) but not ryanodine receptor (RyR) expression was high in enamel cells suggesting that IP3Rs are the main ER Ca(2+) release mechanism. Passive depletion of ER Ca(2+) stores with thapsigargin resulted in a significant raise in [Ca(2+)]i consistent with SOCE. In cells pre-treated with the CRAC channel blocker Synta-66 Ca(2+) entry was significantly inhibited. These data demonstrate that enamel cells have SOCE mediated by CRAC channels and implicate them as a mechanism for Ca(2+) uptake in enamel formation.

  1. Visualizing individual sodium channels on the move.

    Science.gov (United States)

    Heinemann, Stefan H

    2012-07-27

    Visualization of voltage-gated sodium channels at work is an important requirement for the understanding of rapid electrical signaling in nerve cells. In this issue of Chemistry & Biology, Ondrus and colleagues have mastered this challenge by chemical synthesis of a fluorescent antagonist and by monitoring single sodium channels in living cells with unprecedented optical resolution. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. CHANNELING OF B-IONS IN SILICON

    NARCIS (Netherlands)

    VOS, M; MITCHELL, [No Value; SMULDERS, PJM

    We present new results on the channeling of B ions in Si crystals. Standard surface barrier detectors have been used to record energy spectra for B ions backscattered from the near surface (approximately 1500 angstrom) of a silicon crystal, under perfect, and near axial and planar channeling

  3. TRANSMISSION ION CHANNELING IMAGES OF CRYSTAL DEFECTS

    NARCIS (Netherlands)

    KING, PJC; BREESE, MBH; WILSHAW, PR; SMULDERS, PJM; GRIME, GW

    This paper demonstrates how images of crystal defects can be produced using ion channeling. A focused, scanned beam of MeV protons from the University of Oxford Nuclear Microprobe has been used. With the beam aligned with a channeling direction of the crystal, protons transmitted through the thinned

  4. Privacy of a lossy bosonic memory channel

    International Nuclear Information System (INIS)

    Ruggeri, Giovanna; Mancini, Stefano

    2007-01-01

    We study the security of the information transmission between two honest parties realized through a lossy bosonic memory channel when losses are captured by a dishonest party. We then show that entangled inputs can enhance the private information of such a channel, which however does never overcome that of unentangled inputs in absence of memory

  5. BK channel modulators: a comprehensive overview

    DEFF Research Database (Denmark)

    Nardi, Antonio; Olesen, Søren-Peter

    2008-01-01

    channels as a potentially attractive target, the design and synthesis of potent and selective BK modulators continue based on novel chemical ideas. A comprehensive overview of BK channel modulators is therefore timely and important to the current medicinal chemist for review, summary, and classification...

  6. Micromachining of buried micro channels in silicon

    NARCIS (Netherlands)

    de Boer, Meint J.; Tjerkstra, R.W.; Berenschot, Johan W.; Jansen, Henricus V.; Burger, G.J.; Burger, G.J.; Gardeniers, Johannes G.E.; Elwenspoek, Michael Curt; van den Berg, Albert

    A new method for the fabrication of micro structures for fluidic applications, such as channels, cavities, and connector holes in the bulk of silicon wafers, called buried channel technology (BCT), is presented in this paper. The micro structures are constructed by trench etching, coating of the

  7. Remarks to the hot channel power characteristics

    International Nuclear Information System (INIS)

    Tinka, I.; Tinkova, E.

    2002-01-01

    In connection with methodological improvements of safety analyses, some effects of detail power distributions, that should be taken into account for the hot channel characteristics determination, have been studied. This determination concerns the whole channel power (power of the fuel rod) and its axial (along the channel) and radial (across the fuel pellet radius) distribution. The total power of the channel is studied from the point of possible restrictions for different numbers of main cooling loops in operation. For radial power distribution the effect of burnup has been studied and for axial distribution the effect of the control rod vicinity (its coupler part) has been evaluated. The DNBR and fuel temperatures have been the key safety parameters influenced by these hot channel characteristics and have been evaluated in this study (Authors)

  8. Spiking neural P systems with multiple channels.

    Science.gov (United States)

    Peng, Hong; Yang, Jinyu; Wang, Jun; Wang, Tao; Sun, Zhang; Song, Xiaoxiao; Luo, Xiaohui; Huang, Xiangnian

    2017-11-01

    Spiking neural P systems (SNP systems, in short) are a class of distributed parallel computing systems inspired from the neurophysiological behavior of biological spiking neurons. In this paper, we investigate a new variant of SNP systems in which each neuron has one or more synaptic channels, called spiking neural P systems with multiple channels (SNP-MC systems, in short). The spiking rules with channel label are introduced to handle the firing mechanism of neurons, where the channel labels indicate synaptic channels of transmitting the generated spikes. The computation power of SNP-MC systems is investigated. Specifically, we prove that SNP-MC systems are Turing universal as both number generating and number accepting devices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Ergodic Capacity for the SIMO Nakagami- Channel

    Directory of Open Access Journals (Sweden)

    Vagenas EfstathiosD

    2009-01-01

    Full Text Available This paper presents closed-form expressions for the ergodic channel capacity of SIMO (single-input and multiple output wireless systems operating in a Nakagami- fading channel. As the performance of SIMO channel is closely related to the diversity combining techniques, we present closed-form expressions for the capacity of maximal ratio combining (MRC, equal gain combining (EGC, selection combining (SC, and switch and stay (SSC diversity systems operating in Nakagami- fading channels. Also, the ergodic capacity of a SIMO system in a Nakagami- fading channel without any diversity technique is derived. The latter scenario is further investigated for a large amount of receive antennas. Finally, numerical results are presented for illustration.

  10. [Channels: a new way to revisit pathology].

    Science.gov (United States)

    Fournier, Emmanuel

    2014-02-01

    Many "essential" diseases that manifest themselves in the form of crises or fits (epilepsies, episodic ataxia, periodic paralyses, myotonia, heart rhythm disorders, etc.) are due to ionic channel dysfunction and are thus referred to as "channelopathies". Some of these disorders are congenital, due to mutations of genes encoding channel subunits, while others result from toxic, immune or hormonal disturbances affecting channelfunction. Channelopathies take on a wide variety of clinical forms, depending on the type of channel (sodium, potassium, calcium, chloride...) and the type of dysfunction (loss or gain of function). Some apparently unrelated diseases affecting distinct organs are due to a similar dysfunction of the same channel, revealing unsuspected relationships between organs and between medical specialties. In addition, a given syndrome can be caused by distinct channel dysfunctions. This provides new opportunities for diferential diagnosis and specific correction of the causal defects, although some treatments find applications across multiple medical specialties.

  11. Customers’ Perception regarding Assurance of Bancassurance Channel

    Directory of Open Access Journals (Sweden)

    Choudhury Mousumi

    2016-12-01

    Full Text Available Bancassurance has evolved as a strong distribution channel in India. Bancassurance means that the insurance company and the bank come together to offer insurance products from the counter of the banks to the bank’s customer. The present study attempts to analyse customers’ perception regarding assurance of bancassurance channel in providing insurance-related services. The study also tries to find out the impact of various demographic variables on customers’ perception regarding assurance of bancassurance channel. The study finds that customers consider bancassurance channel having high assurance in providing insurance services. It is also found in the study that there is no significant association between the demographic variables considered in the study and customers’ perception regarding assurance of bancassurance channel.

  12. Coupling of laser energy into plasma channels

    International Nuclear Information System (INIS)

    Dimitrov, D. A.; Giacone, R. E.; Bruhwiler, D. L.; Busby, R.; Cary, J. R.; Geddes, C. G. R.; Esarey, E.; Leemans, W. P.

    2007-01-01

    Diffractive spreading of a laser pulse imposes severe limitations on the acceleration length and maximum electron energy in the laser wake field accelerator (LWFA). Optical guiding of a laser pulse via plasma channels can extend the laser-plasma interaction distance over many Rayleigh lengths. Energy efficient coupling of laser pulses into and through plasma channels is very important for optimal LWFA performance. Results from simulation parameter studies on channel guiding using the particle-in-cell (PIC) code VORPAL [C. Nieter and J. R. Cary, J. Comput. Phys. 196, 448 (2004)] are presented and discussed. The effects that density ramp length and the position of the laser pulse focus have on coupling into channels are considered. Moreover, the effect of laser energy leakage out of the channel domain and the effects of tunneling ionization of a neutral gas on the guided laser pulse are also investigated. Power spectral diagnostics were developed and used to separate pump depletion from energy leakage. The results of these simulations show that increasing the density ramp length decreases the efficiency of coupling a laser pulse to a channel and increases the energy loss when the pulse is vacuum focused at the channel entrance. Then, large spot size oscillations result in increased energy leakage. To further analyze the coupling, a differential equation is derived for the laser spot size evolution in the plasma density ramp and channel profiles are simulated. From the numerical solution of this equation, the optimal spot size and location for coupling into a plasma channel with a density ramp are determined. This result is confirmed by the PIC simulations. They show that specifying a vacuum focus location of the pulse in front of the top of the density ramp leads to an actual focus at the top of the ramp due to plasma focusing, resulting in reduced spot size oscillations. In this case, the leakage is significantly reduced and is negligibly affected by ramp length

  13. Dysfunctional HCN ion channels in neurological diseases

    Directory of Open Access Journals (Sweden)

    Jacopo C. DiFrancesco

    2015-03-01

    Full Text Available Hyperpolarization-activated cyclic nucleotide-gated (HCN channels are expressed as four different isoforms (HCN1-4 in the heart and in the central and peripheral nervous systems. HCN channels are activated by membrane hyperpolarization at voltages close to resting membrane potentials and carry the hyperpolarization-activated current, dubbed If (funny current in heart and Ih in neurons. HCN channels contribute in several ways to neuronal activity and are responsible for many important cellular functions, including cellular excitability, generation and modulation of rhythmic activity, dendritic integration, transmission of synaptic potentials and plasticity phenomena. Because of their role, defective HCN channels are natural candidates in the search for potential causes of neurological disorders in humans. Several data, including growing evidence that some forms of epilepsy are associated with HCN mutations, support the notion of an involvement of dysfunctional HCN channels in different experimental models of the disease. Additionally, some anti-epileptic drugs are known to modify the activity of the Ih current. HCN channels are widely expressed in the peripheral nervous system and recent evidence has highlighted the importance of the HCN2 isoform in the transmission of pain. HCN channels are also present in the midbrain system, where they finely regulate the activity of dopaminergic neurons, and a potential role of these channels in the pathogenesis of Parkinson’s disease has recently emerged. The function of HCN channels is regulated by specific accessory proteins, which control the correct expression and modulation of the neuronal Ih current. Alteration of these proteins can severely interfere with the physiological channel function, potentially predisposing to pathological conditions. In this review we address the present knowledge of the association between HCN dysfunctions and neurological diseases, including clinical, genetic and

  14. Assesment of strength and integrity of fuel channels

    International Nuclear Information System (INIS)

    2000-01-01

    Detailed analysis to base strength and integrity of fuel channels was necessary for the licensing process. Description of tasks performed in this direction in 1999 is presented: fuel channel independent strength calculations, assessment of present fuel channels state, analysis of dynamic processes during partial group distribution header rupture, structural integrity analysis of fuel channels located next to broke channel

  15. Channel and Timeslot Co-Scheduling with Minimal Channel Switching for Data Aggregation in MWSNs

    Directory of Open Access Journals (Sweden)

    Sanggil Yeoum

    2017-05-01

    Full Text Available Collision-free transmission and efficient data transfer between nodes can be achieved through a set of channels in multichannel wireless sensor networks (MWSNs. While using multiple channels, we have to carefully consider channel interference, channel and time slot (resources optimization, channel switching delay, and energy consumption. Since sensor nodes operate on low battery power, the energy consumed in channel switching becomes an important challenge. In this paper, we propose channel and time slot scheduling for minimal channel switching in MWSNs, while achieving efficient and collision-free transmission between nodes. The proposed scheme constructs a duty-cycled tree while reducing the amount of channel switching. As a next step, collision-free time slots are assigned to every node based on the minimal data collection delay. The experimental results demonstrate that the validity of our scheme reduces the amount of channel switching by 17.5%, reduces energy consumption for channel switching by 28%, and reduces the schedule length by 46%, as compared to the existing schemes.

  16. Disguising quantum channels by mixing and channel distance trade-off

    International Nuclear Information System (INIS)

    Fung, Chi-Hang Fred; Chau, H F

    2014-01-01

    We consider the reverse problem of the distinguishability of two quantum channels, which we call the disguising problem. Given two quantum channels, the goal here is to make the two channels identical by mixing with some other channels with minimal mixing probabilities. This quantifies how much one channel can disguise as the other. In addition, the possibility to trade-off between the two mixing probabilities allows one channel to be more preserved (less mixed) at the expense of the other. We derive lower- and upper-bounds of the trade-off curve and apply them to a few example channels. Optimal trade-off is obtained in one example. We relate the disguising problem and the distinguishability problem by showing that the former can lower and upper bound the diamond norm. We also show that the disguising problem gives an upper-bound on the key generation rate in quantum cryptography. (paper)

  17. Evolutionary origins of mechanosensitive ion channels.

    Science.gov (United States)

    Martinac, Boris; Kloda, Anna

    2003-01-01

    According to the recent revision, the universal phylogenetic tree is composed of three domains: Eukarya (eukaryotes), Bacteria (eubacteria) and Archaea (archaebacteria). Mechanosensitive (MS) ion channels have been documented in cells belonging to all three domains suggesting their very early appearance during evolution of life on Earth. The channels show great diversity in conductance, selectivity and voltage dependence, while sharing the property of being gated by mechanical stimuli exerted on cell membranes. In prokaryotes, MS channels were first documented in Bacteria followed by their discovery in Archaea. The finding of MS channels in archaeal cells helped to recognize and establish the evolutionary relationship between bacterial and archaeal MS channels and to show that this relationship extends to eukaryotic Fungi (Schizosaccharomyces pombe) and Plants (Arabidopsis thaliana). Similar to their bacterial and archaeal homologues, MS channels in eukaryotic cell-walled Fungi and Plants may serve in protecting the cellular plasma membrane from excessive dilation and rupture that may occur during osmotic stress. This review summarizes briefly some of the recent developments in the MS channel research field that may ultimately lead to elucidation of the biophysical and evolutionary principles underlying the mechanosensory transduction in living cells.

  18. Calcium homeostasis modulator (CALHM) ion channels.

    Science.gov (United States)

    Ma, Zhongming; Tanis, Jessica E; Taruno, Akiyuki; Foskett, J Kevin

    2016-03-01

    Calcium homeostasis modulator 1 (CALHM1), formerly known as FAM26C, was recently identified as a physiologically important plasma membrane ion channel. CALHM1 and its Caenorhabditis elegans homolog, CLHM-1, are regulated by membrane voltage and extracellular Ca(2+) concentration ([Ca(2+)]o). In the presence of physiological [Ca(2+)]o (∼1.5 mM), CALHM1 and CLHM-1 are closed at resting membrane potentials but can be opened by strong depolarizations. Reducing [Ca(2+)]o increases channel open probability, enabling channel activation at negative membrane potentials. Together, voltage and Ca(2+) o allosterically regulate CALHM channel gating. Through convergent evolution, CALHM has structural features that are reminiscent of connexins and pannexins/innexins/LRRC8 (volume-regulated anion channel (VRAC)) gene families, including four transmembrane helices with cytoplasmic amino and carboxyl termini. A CALHM1 channel is a hexamer of CALHM1 monomers with a functional pore diameter of ∼14 Å. CALHM channels discriminate poorly among cations and anions, with signaling molecules including Ca(2+) and ATP able to permeate through its pore. CALHM1 is expressed in the brain where it plays an important role in cortical neuron excitability induced by low [Ca(2+)]o and in type II taste bud cells in the tongue that sense sweet, bitter, and umami tastes where it functions as an essential ATP release channel to mediate nonsynaptic neurotransmitter release. CLHM-1 is expressed in C. elegans sensory neurons and body wall muscles, and its genetic deletion causes locomotion defects. Thus, CALHM is a voltage- and Ca(2+) o-gated ion channel, permeable to large cations and anions, that plays important roles in physiology.

  19. Sodium channels as targets for volatile anesthetics

    Directory of Open Access Journals (Sweden)

    Karl F. Herold

    2012-03-01

    Full Text Available The molecular mechanisms of modern inhaled anesthetics although widely used in clinical settings are still poorly understood. Considerable evidence supports effects on membrane proteins such as ligand- and voltage-gated ion channels of excitable cells. Na+ channels are crucial to action potential initiation and propagation, and represent potential targets for volatile anesthetics. Inhibition of presynaptic Na+ channels leads to reduced neurotransmitter release at the synapse and could therefore contribute to the mechanisms by which volatile anesthetics produce their characteristic effects: amnesia, unconsciousness, and immobility. Early studies on crayfish and squid giant axon showed inhibition of Na+ currents by volatile anesthetics. Subsequent studies using native neuronal preparations and heterologous expression systems with various mammalian Na+ channel isoforms implicated inhibition of presynaptic Na+ channels in anesthetic actions. Volatile anesthetics reduce peak Na+ current and shift the voltage of half-maximal steady-state inactivation towards more negative potentials, thus stabilizing the fast-inactivated state. Furthermore recovery from fast-inactivation is slowed together with an enhanced use-dependent block during pulse train protocols. These effects can reduce neurotransmitter release by depressing presynaptic excitability, depolarization and Ca entry, and ultimately transmitter release. This reduction in transmitter release is more portent for glutamatergic vs. GABAergic terminals. Involvement of Na+ channel inhibition in mediating the immobility caused by volatile anesthetics has been demonstrated in animal studies, in which intrathecal infusion of the Na+ channel blocker tetrodotoxin increases volatile anesthetic potency, whereas infusion of the Na+ channels agonist veratridine reduces anesthetic potency. These studies indicate that inhibition of presynaptic Na+ channels by volatile anesthetics is involved in mediating some of

  20. Omni-channel Retail Information Systems

    DEFF Research Database (Denmark)

    Tambo, Torben

    2014-01-01

    key players in the industry of retailing (Wilson, 2012; Verizon, 2012) and covers the idea that anything can be sold anywhere with consistent marketing, reasonable efficiency of the supply chain channels and responsible customer service. This article aims at contributing to a characterisation...... and definition of omni-channel retail information systems (OCRIS) by using the information systems research tradition as a distinctive starting point (Treiblmaier and Strebinger, 2008; Avgerou, 2001; Parboteah et al., 2009). Omni-channel retailing has evolved since 2010 with the ultimate aim of aligning physical...

  1. Multi-channel polarized thermal emitter

    Science.gov (United States)

    Lee, Jae-Hwang; Ho, Kai-Ming; Constant, Kristen P

    2013-07-16

    A multi-channel polarized thermal emitter (PTE) is presented. The multi-channel PTE can emit polarized thermal radiation without using a polarizer at normal emergence. The multi-channel PTE consists of two layers of metallic gratings on a monolithic and homogeneous metallic plate. It can be fabricated by a low-cost soft lithography technique called two-polymer microtransfer molding. The spectral positions of the mid-infrared (MIR) radiation peaks can be tuned by changing the periodicity of the gratings and the spectral separation between peaks are tuned by changing the mutual angle between the orientations of the two gratings.

  2. Channel uranium-graphite reactor mounting

    International Nuclear Information System (INIS)

    Polushkin, K.K.; Kuznetsov, A.G.; Zheleznyakov, B.N.

    1981-01-01

    According to theoretical principles of general engineering technology the engineering experience of construction-mounting works at the NPP with channel uranium-graphite reactors is systematized. Main parameters and structural features of the 1000 MW channel uranium-graphite reactors are considered. The succession of mounting operations, premounting equipment and pipelines preparation and mounting works technique are described. The most efficient methods of fitting, welding and machining of reactor elements are recommended. Main problems of technical control service are discussed. A typical netted diagram of main equipment of channel uranium-graphite reactors mounting is given

  3. Quantum Stackelberg Duopoly Game in Depolarizing Channel

    International Nuclear Information System (INIS)

    Zhu Xia; Kuang Leman

    2008-01-01

    In this paper, we investigate the quantum Stackelberg duopoly (QSD) game in the noise environment with the depolarizing channel expressed by the Kraus-operator representation. It is found that the presence of the damping in the depolarizing channel always leads to the decrease of the quantities of the moves and payoffs of the two players in the QSD game. It is indicated that under certain conditions the first-mover advantage in the QSD game can be weakened due to the presence of the damping in the depolarizing channel.

  4. Tema con variazioni: quantum channel capacity

    Science.gov (United States)

    Kretschmann, Dennis; Werner, Reinhard F.

    2004-02-01

    Channel capacity describes the size of the nearly ideal channels, which can be obtained from many uses of a given channel, using an optimal error correcting code. In this paper we collect and compare minor and major variations in the mathematically precise statements of this idea which have been put forward in the literature. We show that all the variations considered lead to equivalent capacity definitions. In particular, it makes no difference whether one requires mean or maximal errors to go to zero, and it makes no difference whether errors are required to vanish for any sequence of block sizes compatible with the rate, or only for one infinite sequence.

  5. Electronic trade effect of marketing channels

    Directory of Open Access Journals (Sweden)

    Lovreta Stipe

    2009-01-01

    Full Text Available E-commerce has caused many significant changes in marketing channels. Consumers had obtained multiple benefits from e-commerce. In addition, it has increased the level of competition in marketing channels. However, the focus of this paper is multichannel strategy and integration of physical (store and electronic marketing channels. E-commerce has induced dynamic development of multichannel strategy. This strategy has evolved as a consequence of multichannel consumer orientation. In developed economies, consumers are multichannel entities and active marketers aim to meet their requirements by creating multichannel offer.

  6. Multi-Channel Maximum Likelihood Pitch Estimation

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2012-01-01

    In this paper, a method for multi-channel pitch estimation is proposed. The method is a maximum likelihood estimator and is based on a parametric model where the signals in the various channels share the same fundamental frequency but can have different amplitudes, phases, and noise characteristics....... This essentially means that the model allows for different conditions in the various channels, like different signal-to-noise ratios, microphone characteristics and reverberation. Moreover, the method does not assume that a certain array structure is used but rather relies on a more general model and is hence...

  7. Decoding LDPC Convolutional Codes on Markov Channels

    Directory of Open Access Journals (Sweden)

    Kashyap Manohar

    2008-01-01

    Full Text Available Abstract This paper describes a pipelined iterative technique for joint decoding and channel state estimation of LDPC convolutional codes over Markov channels. Example designs are presented for the Gilbert-Elliott discrete channel model. We also compare the performance and complexity of our algorithm against joint decoding and state estimation of conventional LDPC block codes. Complexity analysis reveals that our pipelined algorithm reduces the number of operations per time step compared to LDPC block codes, at the expense of increased memory and latency. This tradeoff is favorable for low-power applications.

  8. Decoding LDPC Convolutional Codes on Markov Channels

    Directory of Open Access Journals (Sweden)

    Chris Winstead

    2008-04-01

    Full Text Available This paper describes a pipelined iterative technique for joint decoding and channel state estimation of LDPC convolutional codes over Markov channels. Example designs are presented for the Gilbert-Elliott discrete channel model. We also compare the performance and complexity of our algorithm against joint decoding and state estimation of conventional LDPC block codes. Complexity analysis reveals that our pipelined algorithm reduces the number of operations per time step compared to LDPC block codes, at the expense of increased memory and latency. This tradeoff is favorable for low-power applications.

  9. Two-Channel Dielectric Wake Field Accelerator

    International Nuclear Information System (INIS)

    Hirshfield, Jay L.

    2012-01-01

    Experimental results are reported for test beam acceleration and deflection in a two-channel, cm-scale, rectangular dielectric-lined wakefield accelerator structure energized by a 14-MeV drive beam. The dominant waveguide mode of the structure is at ∼30 GHz, and the structure is configured to exhibit a high transformer ratio (∼12:1). Accelerated bunches in the narrow secondary channel of the structure are continuously energized via Cherenkov radiation that is emitted by a drive bunch moving in the wider primary channel. Observed energy gains and losses, transverse deflections, and changes in the test bunch charge distribution compare favorably with predictions of theory.

  10. Fluvial processes and channel morphometry of the upper Orashi ...

    African Journals Online (AJOL)

    Fluvial processes and channel morphometry of the upper Orashi basin in ... of channel equilibrium between morphology and hydrology, the Orashi channel is not well ... Drainage basins, watershed morphology, morphometric analysis, Nigeria ...

  11. Multi-channel software defined radio experimental evaluation and analysis

    CSIR Research Space (South Africa)

    Van der Merwe, JR

    2014-09-01

    Full Text Available Multi-channel software-defined radios (SDRs) can be utilised as inexpensive prototyping platforms for transceiver arrays. The application for multi-channel prototyping is discussed and measured results of coherent channels for both receiver...

  12. Bidirectional Fano Algorithm for Lattice Coded MIMO Channels

    KAUST Repository

    Al-Quwaiee, Hessa

    2013-01-01

    channel model. Channel codes based on lattices are preferred due to three facts: lattice codes have simple structure, the code can achieve the limits of the channel, and they can be decoded efficiently using lattice decoders which can be considered

  13. Efficient channel estimation in massive MIMO systems - a distributed approach

    KAUST Repository

    Al-Naffouri, Tareq Y.

    2016-01-01

    We present two efficient algorithms for distributed estimation of channels in massive MIMO systems. The two cases of 1) generic, and 2) sparse channels is considered. The algorithms estimate the impulse response for each channel observed

  14. Research on Cost Information Sharing and Channel Choice in a Dual-Channel Supply Chain

    Directory of Open Access Journals (Sweden)

    Huihui Liu

    2016-01-01

    Full Text Available Many studies examine information sharing in an uncertain demand environment in a supply chain. However there is little literature on cost information sharing in a dual-channel structure consisting of a retail channel and a direct sales channel. Assuming that the retail sale cost and direct sale cost are random variables with a general distribution, the paper investigates the retailer’s choice on cost information sharing in a Bertrand competition model. Based on the equilibrium outcome of information sharing, the manufacturer’s channel choice is discussed in detail. Our paper provides several interesting conclusions. In both single- and dual-channel structures, the retailer has little motivation to share its private cost information which is verified to be valuable for the manufacturer. When the cost correlation between the two channels increases, our analyses show that the manufacturer’s profit improves. However, when channel choice is involved, the value of information could play a different role. The paper finds that a dual-channel structure can benefit the manufacturer only when the cost correlation is sufficiently low. In addition, if the cost correlation is weak, the cost fluctuation will bring out the advantage of a dual-channel structure and adding a new direct channel will help in risk pooling.

  15. Channel Planform Dynamics Monitoring and Channel Stability Assessment in Two Sediment-Rich Rivers in Taiwan

    Directory of Open Access Journals (Sweden)

    Cheng-Wei Kuo

    2017-01-01

    Full Text Available Recurrent flood events induced by typhoons are powerful agents to modify channel morphology in Taiwan’s rivers. Frequent channel migrations reflect highly sensitive valley floors and increase the risk to infrastructure and residents along rivers. Therefore, monitoring channel planforms is essential for analyzing channel stability as well as improving river management. This study analyzed annual channel changes along two sediment-rich rivers, the Zhuoshui River and the Gaoping River, from 2008 to 2015 based on satellite images of FORMOSAT-2. Channel areas were digitized from mid-catchment to river mouth (~90 km. Channel stability for reaches was assessed through analyzing the changes of river indices including braid index, active channel width, and channel activity. In general, the valley width plays a key role in braided degree, active channel width, and channel activity. These indices increase as the valley width expands whereas the braid index decreases slightly close to the river mouth due to the change of river types. This downstream pattern in the Zhuoshui River was interrupted by hydraulic construction which resulted in limited changes downstream from the weir, due to the lack of water and sediment supply. A 200-year flood, Typhoon Morakot in 2009, induced significant changes in the two rivers. The highly active landscape in Taiwan results in very sensitive channels compared to other regions. An integrated Sensitivity Index was proposed for identifying unstable reaches, which could be a useful reference for river authorities when making priorities in river regulation strategy. This study shows that satellite image monitoring coupled with river indices analysis could be an effective tool to evaluate spatial and temporal changes in channel stability in highly dynamic river systems.

  16. Quantum capacity under adversarial quantum noise: arbitrarily varying quantum channels

    OpenAIRE

    Ahlswede, Rudolf; Bjelakovic, Igor; Boche, Holger; Noetzel, Janis

    2010-01-01

    We investigate entanglement transmission over an unknown channel in the presence of a third party (called the adversary), which is enabled to choose the channel from a given set of memoryless but non-stationary channels without informing the legitimate sender and receiver about the particular choice that he made. This channel model is called arbitrarily varying quantum channel (AVQC). We derive a quantum version of Ahlswede's dichotomy for classical arbitrarily varying channels. This includes...

  17. Channel by Day and Night

    Science.gov (United States)

    2004-01-01

    [figure removed for brevity, see original site] Released 17 June 2004 This pair of images shows part of a small channel. Day/Night Infrared Pairs The image pairs presented focus on a single surface feature as seen in both the daytime and nighttime by the infrared THEMIS camera. The nighttime image (right) has been rotated 180 degrees to place north at the top. Infrared image interpretation Daytime: Infrared images taken during the daytime exhibit both the morphological and thermophysical properties of the surface of Mars. Morphologic details are visible due to the effect of sun-facing slopes receiving more energy than antisun-facing slopes. This creates a warm (bright) slope and cool (dark) slope appearance that mimics the light and shadows of a visible wavelength image. Thermophysical properties are seen in that dust heats up more quickly than rocks. Thus dusty areas are bright and rocky areas are dark. Nighttime: Infrared images taken during the nighttime exhibit only the thermophysical properties of the surface of Mars. The effect of sun-facing versus non-sun-facing energy dissipates quickly at night. Thermophysical effects dominate as different surfaces cool at different rates through the nighttime hours. Rocks cool slowly, and are therefore relatively bright at night (remember that rocks are dark during the day). Dust and other fine grained materials cool very quickly and are dark in nighttime infrared images. Image information: IR instrument. Latitude 19.8, Longitude 141.5 East (218.5 West). 100 meter/pixel resolution. Note: this THEMIS visual image has not been radiometrically nor geometrically calibrated for this preliminary release. An empirical correction has been performed to remove instrumental effects. A linear shift has been applied in the cross-track and down-track direction to approximate spacecraft and planetary motion. Fully calibrated and geometrically projected images will be released through the Planetary Data System in accordance with Project

  18. MODEL OF CHANNEL AIRBORN ELECTRICAL POWER SYSTEM

    Directory of Open Access Journals (Sweden)

    A. G. Demchenko

    2014-01-01

    Full Text Available This article is devoted to math modeling of channel of alternate current airborne electrical power-supply system. Considered to modeling of synchronous generator that runs on three-phase static load.

  19. Optimal unitary dilation for bosonic Gaussian channels

    International Nuclear Information System (INIS)

    Caruso, Filippo; Eisert, Jens; Giovannetti, Vittorio; Holevo, Alexander S.

    2011-01-01

    A general quantum channel can be represented in terms of a unitary interaction between the information-carrying system and a noisy environment. In this paper the minimal number of quantum Gaussian environmental modes required to provide a unitary dilation of a multimode bosonic Gaussian channel is analyzed for both pure and mixed environments. We compute this quantity in the case of pure environment corresponding to the Stinespring representation and give an improved estimate in the case of mixed environment. The computations rely, on one hand, on the properties of the generalized Choi-Jamiolkowski state and, on the other hand, on an explicit construction of the minimal dilation for arbitrary bosonic Gaussian channel. These results introduce a new quantity reflecting ''noisiness'' of bosonic Gaussian channels and can be applied to address some issues concerning transmission of information in continuous variables systems.

  20. Superconducting muon channel at J-PARC

    International Nuclear Information System (INIS)

    Shimomura, K.; Koda, A.; Strasser, P.; Kawamura, N.; Fujimori, H.; Makimura, S.; Higemoto, W.; Nakahara, K.; Ishida, K.; Nishiyama, K.; Nagamine, K.; Miyake, Y.

    2009-01-01

    The Muon Science Laboratory at the Materials and Life Science Facility is now under construction in Japan Proton Accelerator Research Complex (J-PARC), where four types of muon channels are planned to be installed. A conventional superconducting muon channel will be installed at the first stage, which can extract surface (positive) muons and decay positive/negative muons up to 120 MeV/c, and the expected muon yield is a few 10 6 /s at 60 MeV/c (for both positive and negative). This channel will be used for various kinds of experiments like muon catalyzed fusion, μSR and nondestructive elements analysis. The present status of the superconducting muon channel is briefly reported.