WorldWideScience

Sample records for parameter extraction methods

  1. Mechanomyographic Parameter Extraction Methods: An Appraisal for Clinical Applications

    Directory of Open Access Journals (Sweden)

    Morufu Olusola Ibitoye

    2014-12-01

    Full Text Available The research conducted in the last three decades has collectively demonstrated that the skeletal muscle performance can be alternatively assessed by mechanomyographic signal (MMG parameters. Indices of muscle performance, not limited to force, power, work, endurance and the related physiological processes underlying muscle activities during contraction have been evaluated in the light of the signal features. As a non-stationary signal that reflects several distinctive patterns of muscle actions, the illustrations obtained from the literature support the reliability of MMG in the analysis of muscles under voluntary and stimulus evoked contractions. An appraisal of the standard practice including the measurement theories of the methods used to extract parameters of the signal is vital to the application of the signal during experimental and clinical practices, especially in areas where electromyograms are contraindicated or have limited application. As we highlight the underpinning technical guidelines and domains where each method is well-suited, the limitations of the methods are also presented to position the state of the art in MMG parameters extraction, thus providing the theoretical framework for improvement on the current practices to widen the opportunity for new insights and discoveries. Since the signal modality has not been widely deployed due partly to the limited information extractable from the signals when compared with other classical techniques used to assess muscle performance, this survey is particularly relevant to the projected future of MMG applications in the realm of musculoskeletal assessments and in the real time detection of muscle activity.

  2. Improved Cole parameter extraction based on the least absolute deviation method

    International Nuclear Information System (INIS)

    Yang, Yuxiang; Ni, Wenwen; Sun, Qiang; Wen, He; Teng, Zhaosheng

    2013-01-01

    The Cole function is widely used in bioimpedance spectroscopy (BIS) applications. Fitting the measured BIS data onto the model and then extracting the Cole parameters (R 0 , R ∞ , α and τ) is a common practice. Accurate extraction of the Cole parameters from the measured BIS data has great significance for evaluating the physiological or pathological status of biological tissue. The traditional least-squares (LS)-based curve fitting method for Cole parameter extraction is often sensitive to noise or outliers and becomes non-robust. This paper proposes an improved Cole parameter extraction based on the least absolute deviation (LAD) method. Comprehensive simulation experiments are carried out and the performances of the LAD method are compared with those of the LS method under the conditions of outliers, random noises and both disturbances. The proposed LAD method exhibits much better robustness under all circumstances, which demonstrates that the LAD method is deserving as an improved alternative to the LS method for Cole parameter extraction for its robustness to outliers and noises. (paper)

  3. Development of a new compound method to extract the five parameters of PV modules

    International Nuclear Information System (INIS)

    Bai, Jianbo; Liu, Sheng; Hao, Yuzhe; Zhang, Zhen; Jiang, Meng; Zhang, Yu

    2014-01-01

    Highlights: • A compound method to extract the five parameters of the five-parameter PV model. • A piecewise curve-fitting method to obtain the differential values at the short and open circuit points. • Simulated and experimental I–V and P–V curves at any operating conditions have excellent agreement. • Prediction of generation output for a PV power station has high accuracy. - Abstract: The five-parameter photovoltaic (PV) mathematical model has been considered a reliable and accurate method for simulating the performance of PV modules. This paper puts forth a new compound method to extract the five parameters of the model with the basic manufacture template data. As the two differential values at the short and open circuit points of the I–V curve at standard testing conditions (STC) are fundamental data to obtain the five parameters and not normally available from the template data, we use a piecewise I–V curve-fitting method combined with the four-parameter PV model to calculate them with which an explicit extraction method is then presented to extract the five parameters at STC conditions by using five individual algebraic equations. Furthermore, the five parameters are revised according to certain operating conditions. In order to evaluate the effectiveness of the proposed method, the simulated I–V characteristic curves for three types of PV modules over a range of operating conditions are compared with the measured data. The experimental results demonstrate that the method has high accuracy. This method is also used to predict the generation power of an actual PV power station; the simulation results show good agreement with the field data. This proposed method is easy to carry out and especially useful for simulating the actual performances of PV modules or arrays at various operating conditions and predicting the output power of real PV power stations

  4. Some properties of 2-D dielectric-based ENG/MNG material parameters extracted using the S-parameter method

    DEFF Research Database (Denmark)

    Wu, Yunqiu; Arslanagic, Samel

    This work presents a systematic investigation of material parameters for two-dimensional epsilon-negative (ENG) and mu-negative (MNG) materials as obtained by the scattering parameter method. The unit cell consists of infinite dielectric cylinders, their sizes and permittivities are chosen...... to enable the ENG and MNG behaviors. For the both configurations, the permittivity and the permeability is reported. Influence of several effects on the extracted material parameters is examined, including the loss inside the cylinders and the size of the unit cells...

  5. The Virtual Fields Method Extracting Constitutive Mechanical Parameters from Full-field Deformation Measurements

    CERN Document Server

    Pierron, Fabrice

    2012-01-01

    The Virtual Fields Method: Extracting Constitutive Mechanical Parameters from Full-field Deformation Measurements is the first book on the Virtual Fields Method (VFM), a technique to identify materials mechanical properties from full-field measurements. Firmly rooted with extensive theoretical description of the method, the book presents numerous examples of application to a wide range of materials (composites, metals, welds, biomaterials) and situations (static, vibration, high strain rate). The authors give a detailed training section with examples of progressive difficulty to lead the reader to program the VFM and include a set of commented Matlab programs as well as GUI Matlab-based software for more general situations. The Virtual Fields Method: Extracting Constitutive Mechanical Parameters from Full-field Deformation Measurements is an ideal book for researchers, engineers, and students interested in applying the VFM to new situations motivated by their research.  

  6. Method for extracting relevant electrical parameters from graphene field-effect transistors using a physical model

    International Nuclear Information System (INIS)

    Boscá, A.; Pedrós, J.; Martínez, J.; Calle, F.

    2015-01-01

    Due to its intrinsic high mobility, graphene has proved to be a suitable material for high-speed electronics, where graphene field-effect transistor (GFET) has shown excellent properties. In this work, we present a method for extracting relevant electrical parameters from GFET devices using a simple electrical characterization and a model fitting. With experimental data from the device output characteristics, the method allows to calculate parameters such as the mobility, the contact resistance, and the fixed charge. Differentiated electron and hole mobilities and direct connection with intrinsic material properties are some of the key aspects of this method. Moreover, the method output values can be correlated with several issues during key fabrication steps such as the graphene growth and transfer, the lithographic steps, or the metalization processes, providing a flexible tool for quality control in GFET fabrication, as well as a valuable feedback for improving the material-growth process

  7. Method for extracting relevant electrical parameters from graphene field-effect transistors using a physical model

    Energy Technology Data Exchange (ETDEWEB)

    Boscá, A., E-mail: alberto.bosca@upm.es [Instituto de Sistemas Optoelectrónicos y Microtecnología, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Dpto. de Ingeniería Electrónica, E.T.S.I. de Telecomunicación, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Pedrós, J. [Instituto de Sistemas Optoelectrónicos y Microtecnología, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Campus de Excelencia Internacional, Campus Moncloa UCM-UPM, Madrid 28040 (Spain); Martínez, J. [Instituto de Sistemas Optoelectrónicos y Microtecnología, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Dpto. de Ciencia de Materiales, E.T.S.I de Caminos, Canales y Puertos, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Calle, F. [Instituto de Sistemas Optoelectrónicos y Microtecnología, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Dpto. de Ingeniería Electrónica, E.T.S.I. de Telecomunicación, Universidad Politécnica de Madrid, Madrid 28040 (Spain); Campus de Excelencia Internacional, Campus Moncloa UCM-UPM, Madrid 28040 (Spain)

    2015-01-28

    Due to its intrinsic high mobility, graphene has proved to be a suitable material for high-speed electronics, where graphene field-effect transistor (GFET) has shown excellent properties. In this work, we present a method for extracting relevant electrical parameters from GFET devices using a simple electrical characterization and a model fitting. With experimental data from the device output characteristics, the method allows to calculate parameters such as the mobility, the contact resistance, and the fixed charge. Differentiated electron and hole mobilities and direct connection with intrinsic material properties are some of the key aspects of this method. Moreover, the method output values can be correlated with several issues during key fabrication steps such as the graphene growth and transfer, the lithographic steps, or the metalization processes, providing a flexible tool for quality control in GFET fabrication, as well as a valuable feedback for improving the material-growth process.

  8. Use of stochastic methods for robust parameter extraction from impedance spectra

    International Nuclear Information System (INIS)

    Bueschel, Paul; Troeltzsch, Uwe; Kanoun, Olfa

    2011-01-01

    The fitting of impedance models to measured data is an essential step in impedance spectroscopy (IS). Due to often complicated, nonlinear models, big number of parameters, large search spaces and presence of noise, an automated determination of the unknown parameters is a challenging task. The stronger the nonlinear behavior of a model, the weaker is the convergence of the corresponding regression and the probability to trap into local minima increases during parameter extraction. For fast measurements or automatic measurement systems these problems became the limiting factors of use. We compared the usability of stochastic algorithms, evolution, simulated annealing and particle filter with the widely used tool LEVM for parameter extraction for IS. The comparison is based on one reference model by J.R. Macdonald and a battery model used with noisy measurement data. The results show different performances of the algorithms for these two problems depending on the search space and the model used for optimization. The obtained results by particle filter were the best for both models. This method delivers the most reliable result for both cases even for the ill posed battery model.

  9. The method of extraction of subspectra with appreciably different values of hyperfine interaction parameters from Moessbauer spectra

    International Nuclear Information System (INIS)

    Nemtsova, O.M.

    2006-01-01

    The task of Moessbauer spectra processing of complex locally inhomogeneous or multi-phase systems is to reveal subspectral contributions with appreciably different values of hyperfine interaction parameters (HFI) in them. A universal method of processing such spectra is suggested which allows to extract the probability density distribution (PDD) of HFI parameters corresponding to the subspectra with essentially different parameters values. The basis of the method is Tikhonov's regularization method with selection for each subspectrum its own value of the regularization parameter. The universal application of the method is demonstrated in the examples of processing real spectra with different sets of subspectral contributions

  10. Parameter Extraction Method for the Electrical Model of a Silicon Photomultiplier

    Science.gov (United States)

    Licciulli, Francesco; Marzocca, Cristoforo

    2016-10-01

    The availability of an effective electrical model, able to accurately reproduce the signals generated by a Silicon Photo-Multiplier coupled to the front-end electronics, is mandatory when the performance of a detection system based on this kind of detector has to be evaluated by means of reliable simulations. We propose a complete extraction procedure able to provide the whole set of the parameters involved in a well-known model of the detector, which includes the substrate ohmic resistance. The technique allows achieving very good quality of the fit between simulation results provided by the model and experimental data, thanks to accurate discrimination between the quenching and substrate resistances, which results in a realistic set of extracted parameters. The extraction procedure has been applied to a commercial device considering a wide range of different conditions in terms of input resistance of the front-end electronics and interconnection parasitics. In all the considered situations, very good correspondence has been found between simulations and measurements, especially for what concerns the leading edge of the current pulses generated by the detector, which strongly affects the timing performance of the detection system, thus confirming the effectiveness of the model and the associated parameter extraction technique.

  11. A Review of the Scattering-Parameter Extraction Method with Clarification of Ambiguity Issues in Relation to Metamaterial Homogenization

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Hansen, Troels Vejle; Mortensen, N. Asger

    2013-01-01

    The scattering-parameter extraction method of metamaterial homogenization is reviewed to show that the only ambiguity is that related to the choice of the branch of the complex logarithmic function (or the complex inverse cosine function). It is shown that the method has no ambiguity for the sign...

  12. A Model Parameter Extraction Method for Dielectric Barrier Discharge Ozone Chamber using Differential Evolution

    Science.gov (United States)

    Amjad, M.; Salam, Z.; Ishaque, K.

    2014-04-01

    In order to design an efficient resonant power supply for ozone gas generator, it is necessary to accurately determine the parameters of the ozone chamber. In the conventional method, the information from Lissajous plot is used to estimate the values of these parameters. However, the experimental setup for this purpose can only predict the parameters at one operating frequency and there is no guarantee that it results in the highest ozone gas yield. This paper proposes a new approach to determine the parameters using a search and optimization technique known as Differential Evolution (DE). The desired objective function of DE is set at the resonance condition and the chamber parameter values can be searched regardless of experimental constraints. The chamber parameters obtained from the DE technique are validated by experiment.

  13. Extraction method

    International Nuclear Information System (INIS)

    Stary, J.; Kyrs, M.; Navratil, J.; Havelka, S.; Hala, J.

    1975-01-01

    Definitions of the basic terms and of relations are given and the knowledge is described of the possibilities of the extraction of elements, oxides, covalent-bound halogenides and heteropolyacids. Greatest attention is devoted to the detailed analysis of the extraction of chelates and ion associates using diverse agents. For both types of compounds detailed conditions are given of the separation and the effects of the individual factors are listed. Attention is also devoted to extractions using mixtures of organic agents, the synergic effects thereof, and to extractions in non-aqueous solvents. The effects of radiation on extraction and the main types of apparatus used for extractions carried out in the laboratory are described. (L.K.)

  14. A Poisson nonnegative matrix factorization method with parameter subspace clustering constraint for endmember extraction in hyperspectral imagery

    Science.gov (United States)

    Sun, Weiwei; Ma, Jun; Yang, Gang; Du, Bo; Zhang, Liangpei

    2017-06-01

    A new Bayesian method named Poisson Nonnegative Matrix Factorization with Parameter Subspace Clustering Constraint (PNMF-PSCC) has been presented to extract endmembers from Hyperspectral Imagery (HSI). First, the method integrates the liner spectral mixture model with the Bayesian framework and it formulates endmember extraction into a Bayesian inference problem. Second, the Parameter Subspace Clustering Constraint (PSCC) is incorporated into the statistical program to consider the clustering of all pixels in the parameter subspace. The PSCC could enlarge differences among ground objects and helps finding endmembers with smaller spectrum divergences. Meanwhile, the PNMF-PSCC method utilizes the Poisson distribution as the prior knowledge of spectral signals to better explain the quantum nature of light in imaging spectrometer. Third, the optimization problem of PNMF-PSCC is formulated into maximizing the joint density via the Maximum A Posterior (MAP) estimator. The program is finally solved by iteratively optimizing two sub-problems via the Alternating Direction Method of Multipliers (ADMM) framework and the FURTHESTSUM initialization scheme. Five state-of-the art methods are implemented to make comparisons with the performance of PNMF-PSCC on both the synthetic and real HSI datasets. Experimental results show that the PNMF-PSCC outperforms all the five methods in Spectral Angle Distance (SAD) and Root-Mean-Square-Error (RMSE), and especially it could identify good endmembers for ground objects with smaller spectrum divergences.

  15. Experimental and numerical investigations of oscillations in extracted material parameters for finite Bragg stacks using the NRW method

    DEFF Research Database (Denmark)

    Clausen, Niels Christian Jerichau; Arslanagic, Samel; Breinbjerg, Olav

    2012-01-01

    A 1D dielectric finite Bragg stack situated in a rectangular waveguide and illuminated by the fundamental TE10 mode is examined analytically, numerically, and experimentally. Calculated as well as measured scattering parameters are used to extract the effective/equivalent material parameters...... for three specific configurations of its constituent unit cell. Particular attention is devoted to the absence/presence of certain oscillations in the extracted material parameters, depending on the unit cell configuration. The results for the finite Bragg stack are further verified to agree with those...... of an infinite Bragg stack, for which the dispersion equation is used in conjunction with the Floquet-Bloch harmonics expansion to extract the material parameters. It is shown that the extracted material parameters for the finite and infinite Bragg stacks agree for the symmetric unit cell configuration....

  16. Parameter extraction with neural networks

    Science.gov (United States)

    Cazzanti, Luca; Khan, Mumit; Cerrina, Franco

    1998-06-01

    with desired characteristics. Using this method, we can extract optimum values for the parameters and determine the process latitude very quickly.

  17. Test of a new method for seismic indices and granulation parameters extraction

    Directory of Open Access Journals (Sweden)

    Peralta R. A.

    2015-01-01

    Full Text Available In the framework of the data base project SSI (Stellar Seismic Indicesb, we have developed and tested a new method aiming at optimizing the simultaneous measurement of both the seismic indices characterizing the oscillations (Δν, νmax and the indices characterizing the granulation signature. Here, we describe this method which is intended to take advantage of the MLE (maximum likelihood estimate algorithm combined with the parametrized representation of the red giants pulsation spectrum following the Universal Pattern [6]. We report its performances tested on Monte Carlo simulations.

  18. Single- and multi-layered all-dielectric ENG, MNG, and DNG material parameter extraction by use of the S-parameter method

    DEFF Research Database (Denmark)

    Wu, Yunqiu; Arslanagic, Samel

    2016-01-01

    modes inside the structure. This enables the ENG, MNG, and DNG behaviors. The material parameters are obtained from the simulated S-parameters by use of the Nicholson-Ross-Weir method. For the 2-layer structure in particular, the results show a possibility of DNG realization with a negative refractive...

  19. Influence of Extraction Parameters on Hydroalcohol Extracts of the ...

    African Journals Online (AJOL)

    The parameter that had the greatest influence on extraction process was alcohol concentration ... rules and processing steps [2]. As part .... Table 1: Extractive batch nnumbers with the respective factors and levels studied in the factorial design.

  20. Statistical MOSFET Parameter Extraction with Parameter Selection for Minimal Point Measurement

    Directory of Open Access Journals (Sweden)

    Marga Alisjahbana

    2013-11-01

    Full Text Available A method to statistically extract MOSFET model parameters from a minimal number of transistor I(V characteristic curve measurements, taken during fabrication process monitoring. It includes a sensitivity analysis of the model, test/measurement point selection, and a parameter extraction experiment on the process data. The actual extraction is based on a linear error model, the sensitivity of the MOSFET model with respect to the parameters, and Newton-Raphson iterations. Simulated results showed good accuracy of parameter extraction and I(V curve fit for parameter deviations of up 20% from nominal values, including for a process shift of 10% from nominal.

  1. Contact effects analyzed by a parameter extraction method based on a single bottom-gate/top-contact organic thin-film transistor

    Science.gov (United States)

    Takagaki, Shunsuke; Yamada, Hirofumi; Noda, Kei

    2018-03-01

    Contact effects in organic thin-film transistors (OTFTs) were examined by using our previously proposed parameter extraction method from the electrical characteristics of a single staggered-type device. Gate-voltage-dependent contact resistance and channel mobility in the linear regime were evaluated for bottom-gate/top-contact (BGTC) pentacene TFTs with active layers of different thicknesses, and for pentacene TFTs with contact-doped layers prepared by coevaporation of pentacene and tetrafluorotetracyanoquinodimethane (F4TCNQ). The extracted parameters suggested that the influence of the contact resistance becomes more prominent with the larger active-layer thickness, and that contact-doping experiments give rise to a drastic decrease in the contact resistance and a concurrent considerable improvement in the channel mobility. Additionally, the estimated energy distributions of trap density in the transistor channel probably reflect the trap filling with charge carriers injected into the channel regions. The analysis results in this study confirm the effectiveness of our proposed method, with which we can investigate contact effects and circumvent the influences of characteristic variations in OTFT fabrication.

  2. Influence of Extraction Parameters on Hydroalcohol Extracts of the ...

    African Journals Online (AJOL)

    ... the influence of alcohol concentration (50, 70 and 90 % v/v), extraction time (2, 6 and 10 h), and particle size of the herbal drug (0.25, 0.5 and 1.0 mm) on the pH, dry residue and myrsinoic acid B (MAB) content of hydroalcoholic extracts by high performance liquid chromatography (HPLC) method. Results: For the extracts, ...

  3. Comparison of results from simple expressions for MOSFET parameter extraction

    Science.gov (United States)

    Buehler, M. G.; Lin, Y.-S.

    1988-01-01

    In this paper results are compared from a parameter extraction procedure applied to the linear, saturation, and subthreshold regions for enhancement-mode MOSFETs fabricated in a 3-micron CMOS process. The results indicate that the extracted parameters differ significantly depending on the extraction algorithm and the distribution of I-V data points. It was observed that KP values vary by 30 percent, VT values differ by 50 mV, and Delta L values differ by 1 micron. Thus for acceptance of wafers from foundries and for modeling purposes, the extraction method and data point distribution must be specified. In this paper measurement and extraction procedures that will allow a consistent evaluation of measured parameters are discussed.

  4. Extraction Methods, Variability Encountered in

    NARCIS (Netherlands)

    Bodelier, P.L.E.; Nelson, K.E.

    2014-01-01

    Synonyms Bias in DNA extractions methods; Variation in DNA extraction methods Definition The variability in extraction methods is defined as differences in quality and quantity of DNA observed using various extraction protocols, leading to differences in outcome of microbial community composition

  5. Vegetation Parameter Extraction Using Dual Baseline Polarimetric SAR Interferometry Data

    Science.gov (United States)

    Zhang, H.; Wang, C.; Chen, X.; Tang, Y.

    2009-04-01

    For vegetation parameter inversion, the single baseline polarimetric SAR interferometry (POLinSAR) technique, such as the three-stage method and the ESPRIT algorithm, is limited by the observed data with the minimum ground to volume amplitude ration, which effects the estimation of the effective phase center for the vegetation canopy or the surface, and thus results in the underestimated vegetation height. In order to remove this effect of the single baseline inversion techniques in some extend, another baseline POLinSAR data is added on vegetation parameter estimation in this paper, and a dual baseline POLinSAR technique for the extraction of the vegetation parameter is investigated and improved to reduce the dynamic bias for the vegetation parameter estimation. Finally, the simulated data and real data are used to validate this dual baseline technique.

  6. The Effect of Truncation of Periodic Structures on NRW Material Parameter Extraction

    DEFF Research Database (Denmark)

    Clausen, Niels Christian Jerichau; Arslanagic, Samel; Breinbjerg, Olav

    2014-01-01

    Using the Nicolson-Ross-Weir (NRW) material parameter extraction method, we compare the difference between using 1 or 10 cells when obtaining the scattering parameters. Obviously these parameters are different, but we see that we practically extract the same propagation constant, wave impedance, ......, permittivity and permeability....

  7. Comparison of mentha extracts obtained by different extraction methods

    Directory of Open Access Journals (Sweden)

    Milić Slavica

    2006-01-01

    Full Text Available The different methods of mentha extraction, such as steam distillation, extraction by methylene chloride (Soxhlet extraction and supercritical fluid extraction (SFE by carbon dioxide (CO J were investigated. SFE by CO, was performed at pressure of 100 bar and temperature of40°C. The extraction yield, as well as qualitative and quantitative composition of obtained extracts, determined by GC-MS method, were compared.

  8. Parameter extraction from I-V characteristics of PV devices

    Energy Technology Data Exchange (ETDEWEB)

    Macabebe, Erees Queen B. [Department of Electronics, Computer and Communications Engineering, Ateneo de Manila University, Loyola Heights, Quezon City 1108 (Philippines); Department of Physics and Centre for Energy Research, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth 6031 (South Africa); Sheppard, Charles J. [Department of Physics, University of Johannesburg, PO Box 524, Auckland Park 2006 (South Africa); Dyk, E. Ernest van [Department of Physics and Centre for Energy Research, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth 6031 (South Africa)

    2011-01-15

    Device parameters such as series and shunt resistances, saturation current and diode ideality factor influence the behaviour of the current-voltage (I-V) characteristics of solar cells and photovoltaic modules. It is necessary to determine these parameters since performance parameters are derived from the I-V curve and information provided by the device parameters are useful in analyzing performance losses. This contribution presents device parameters of CuIn(Se,S){sub 2}- and Cu(In,Ga)(Se,S){sub 2}-based solar cells, as well as, CuInSe{sub 2}, mono- and multicrystalline silicon modules determined using a parameter extraction routine that employs Particle Swarm Optimization. The device parameters of the CuIn(Se,S){sub 2}- and Cu(In,Ga)(Se,S){sub 2}-based solar cells show that the contribution of recombination mechanisms exhibited by high saturation current when coupled with the effects of parasitic resistances result in lower maximum power and conversion efficiency. Device parameters of photovoltaic modules extracted from I-V characteristics obtained at higher temperature show increased saturation current. The extracted values also reflect the adverse effect of temperature on parasitic resistances. The parameters extracted from I-V curves offer an understanding of the different mechanisms involved in the operation of the devices. The parameter extraction routine utilized in this study is a useful tool in determining the device parameters which reveal the mechanisms affecting device performance. (author)

  9. Automatic facial animation parameters extraction in MPEG-4 visual communication

    Science.gov (United States)

    Yang, Chenggen; Gong, Wanwei; Yu, Lu

    2002-01-01

    Facial Animation Parameters (FAPs) are defined in MPEG-4 to animate a facial object. The algorithm proposed in this paper to extract these FAPs is applied to very low bit-rate video communication, in which the scene is composed of a head-and-shoulder object with complex background. This paper addresses the algorithm to automatically extract all FAPs needed to animate a generic facial model, estimate the 3D motion of head by points. The proposed algorithm extracts human facial region by color segmentation and intra-frame and inter-frame edge detection. Facial structure and edge distribution of facial feature such as vertical and horizontal gradient histograms are used to locate the facial feature region. Parabola and circle deformable templates are employed to fit facial feature and extract a part of FAPs. A special data structure is proposed to describe deformable templates to reduce time consumption for computing energy functions. Another part of FAPs, 3D rigid head motion vectors, are estimated by corresponding-points method. A 3D head wire-frame model provides facial semantic information for selection of proper corresponding points, which helps to increase accuracy of 3D rigid object motion estimation.

  10. Extraction of the Susy and Higgs parameters

    International Nuclear Information System (INIS)

    Adam-Bourdarios, Claire

    2010-01-01

    If supersymmetry is discovered by the next generation of collider experiments, it will be crucial to determine its fundamental high-scale parameters. Three scenarios have been recently investigated by the SFitter collaboration : the case where the LHC 'only' measures a light Higgs like signal, the case where SUSY signal are discovered at the LHC, and the dream scenario, where LHC and ILC measurements can be combined.

  11. Statistical properties of compartmental model parameters extracted from dynamic positron emission tomography experiments

    International Nuclear Information System (INIS)

    Mazoyer, B.M.; Huesman, R.H.; Budinger, T.F.; Knittel, B.L.

    1986-01-01

    Over the past years a major focus of research in physiologic studies employing tracers has been the computer implementation of mathematical methods of kinetic modeling for extracting the desired physiological parameters from tomographically derived data. A study is reported of factors that affect the statistical properties of compartmental model parameters extracted from dynamic positron emission tomography (PET) experiments

  12. Bias-limited extraction of cosmological parameters

    Energy Technology Data Exchange (ETDEWEB)

    Shimon, Meir; Itzhaki, Nissan; Rephaeli, Yoel, E-mail: meirs@wise.tau.ac.il, E-mail: nitzhaki@post.tau.ac.il, E-mail: yoelr@wise.tau.ac.il [School of Physics and Astronomy, Tel Aviv University, Tel Aviv 69978 (Israel)

    2013-03-01

    It is known that modeling uncertainties and astrophysical foregrounds can potentially introduce appreciable bias in the deduced values of cosmological parameters. While it is commonly assumed that these uncertainties will be accounted for to a sufficient level of precision, the level of bias has not been properly quantified in most cases of interest. We show that the requirement that the bias in derived values of cosmological parameters does not surpass nominal statistical error, translates into a maximal level of overall error O(N{sup −½}) on |ΔP(k)|/P(k) and |ΔC{sub l}|/C{sub l}, where P(k), C{sub l}, and N are the matter power spectrum, angular power spectrum, and number of (independent Fourier) modes at a given scale l or k probed by the cosmological survey, respectively. This required level has important consequences on the precision with which cosmological parameters are hoped to be determined by future surveys: in virtually all ongoing and near future surveys N typically falls in the range 10{sup 6}−10{sup 9}, implying that the required overall theoretical modeling and numerical precision is already very high. Future redshifted-21-cm observations, projected to sample ∼ 10{sup 14} modes, will require knowledge of the matter power spectrum to a fantastic 10{sup −7} precision level. We conclude that realizing the expected potential of future cosmological surveys, which aim at detecting 10{sup 6}−10{sup 14} modes, sets the formidable challenge of reducing the overall level of uncertainty to 10{sup −3}−10{sup −7}.

  13. Effects of process parameters on peanut skins extract and CO2 diffusivity by supercritical fluid extraction

    Science.gov (United States)

    Putra, N. R.; Yian, L. N.; Nasir, H. M.; Idham, Z. Binti; Yunus, M. A. C.

    2018-03-01

    Peanut skins (Arachis hypogea) are an agricultural waste product which has received much attention because they contain high nutritional values and can be potentially utilized in difference industries. At present, only a few studies have been conducted to study the effects of parameters on the peanut skins oil extraction. Therefore, this study aimed to determine the best extraction condition in order to obtain the highest extract yield using supercritical carbon dioxide (SC-CO2) with co-solvent Ethanol as compared to Soxhlet extraction method. Diffusivity of carbon dioxide in supercritical fluid extraction was determined using Crank model. The mean particle size used in this study was 425 µm. The supercritical carbon dioxide was performed at temperature (40 – 70 °C), flow rate of co-solvent ethanol (0 - 7.5% Vethanol/Vtotal), and extraction pressure (10 – 30 MPa) were used in this studies. The results showed that the percentage of oil yields and effective diffusivity increase as the pressure, rate of co-solvent, and temperature increased.

  14. The optimal extraction parameters and anti-diabetic activity of ...

    African Journals Online (AJOL)

    diabetic activity of FIBL on alloxan induced diabetic mice were studied. The optimal extraction parameters of FIBL were obtained by single factor test and orthogonal test, as follows: ethanol concentration 60 %, ratio of solvent to raw material 30 ...

  15. A novel method for the extraction of local gravity wave parameters from gridded three-dimensional data: description, validation, and application

    Directory of Open Access Journals (Sweden)

    L. Schoon

    2018-05-01

    Full Text Available For the local diagnosis of wave properties, we develop, validate, and apply a novel method which is based on the Hilbert transform. It is called Unified Wave Diagnostics (UWaDi. It provides the wave amplitude and three-dimensional wave number at any grid point for gridded three-dimensional data. UWaDi is validated for a synthetic test case comprising two different wave packets. In comparison with other methods, the performance of UWaDi is very good with respect to wave properties and their location. For a first practical application of UWaDi, a minor sudden stratospheric warming on 30 January 2016 is chosen. Specifying the diagnostics for hydrostatic inertia–gravity waves in analyses from the European Centre for Medium-Range Weather Forecasts, we detect the local occurrence of gravity waves throughout the middle atmosphere. The local wave characteristics are discussed in terms of vertical propagation using the diagnosed local amplitudes and wave numbers. We also note some hints on local inertia–gravity wave generation by the stratospheric jet from the detection of shallow slow waves in the vicinity of its exit region.

  16. Parameters extraction for perovskite solar cells based on Lambert W-function

    Directory of Open Access Journals (Sweden)

    Ge Junyu

    2016-01-01

    Full Text Available The behaviors of the solar cells are decided by the device parameters. Thus, it is necessary to extract these parameters to achieve the optimal working condition. Because the five-parameter model of solar cells has the implicit equation of current-voltage relationship, it is difficult to obtain the parameters with conventional methods. In this work, an optimized method is presented to extract device parameters from the actual test data of photovoltaic cell. Based on Lambert W-function, explicit formulation of the model can be deduced. The proposed technique takes suitable method of selecting sample points, which are used to calculate the values of the model parameters. By comparing with the Quasi-Newton method, the results verify accuracy and reliability of this method.

  17. Tribulus terrestris Extract Improves Human Sperm Parameters In Vitro

    Science.gov (United States)

    Khaleghi, Sara; Bakhtiari, Mitra; Asadmobini, Atefeh; Esmaeili, Farzane

    2016-01-01

    Objective. The object of present study was to investigate the effects of direct addition of Tribulus terrestris extract on human sperm parameters. Design. Semen specimens from 40 healthy men volunteers were divided into 4 groups: one group received no treatment (control group) while the others were incubated with 20, 40, and 50 µg/mL of T terrestris extract (experimental groups). Motility, viability, and DNA fragmentation were assessed in all groups. Results. The incubation of human semen with 40 and 50 μg/mL of T terrestris extract significantly enhanced total sperm motility, number of progressive motile spermatozoa, and curvilinear velocity over 60 to 120 minutes’ holding time (P terrestris extract (P terrestris extract to human sperm could affect male fertility capacity. PMID:27694560

  18. Tribulus terrestris Extract Improves Human Sperm Parameters In Vitro.

    Science.gov (United States)

    Khaleghi, Sara; Bakhtiari, Mitra; Asadmobini, Atefeh; Esmaeili, Farzane

    2016-09-30

    The object of present study was to investigate the effects of direct addition of Tribulus terrestris extract on human sperm parameters. Semen specimens from 40 healthy men volunteers were divided into 4 groups: one group received no treatment (control group) while the others were incubated with 20, 40, and 50 µg/mL of T terrestris extract (experimental groups). Motility, viability, and DNA fragmentation were assessed in all groups. The incubation of human semen with 40 and 50 μg/mL of T terrestris extract significantly enhanced total sperm motility, number of progressive motile spermatozoa, and curvilinear velocity over 60 to 120 minutes' holding time (P terrestris extract (P terrestris extract to human sperm could affect male fertility capacity. © The Author(s) 2016.

  19. Voltage stability, bifurcation parameters and continuation methods

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado, F L [Wisconsin Univ., Madison, WI (United States)

    1994-12-31

    This paper considers the importance of the choice of bifurcation parameter in the determination of the voltage stability limit and the maximum power load ability of a system. When the bifurcation parameter is power demand, the two limits are equivalent. However, when other types of load models and bifurcation parameters are considered, the two concepts differ. The continuation method is considered as a method for determination of voltage stability margins. Three variants of the continuation method are described: the continuation parameter is the bifurcation parameter the continuation parameter is initially the bifurcation parameter, but is free to change, and the continuation parameter is a new `arc length` parameter. Implementations of voltage stability software using continuation methods are described. (author) 23 refs., 9 figs.

  20. A new approach to the extraction of single exponential diode model parameters

    Science.gov (United States)

    Ortiz-Conde, Adelmo; García-Sánchez, Francisco J.

    2018-06-01

    A new integration method is presented for the extraction of the parameters of a single exponential diode model with series resistance from the measured forward I-V characteristics. The extraction is performed using auxiliary functions based on the integration of the data which allow to isolate the effects of each of the model parameters. A differentiation method is also presented for data with low level of experimental noise. Measured and simulated data are used to verify the applicability of both proposed method. Physical insight about the validity of the model is also obtained by using the proposed graphical determinations of the parameters.

  1. Methods for measurement of durability parameters

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1996-01-01

    Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included.......Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included....

  2. Effects of Extraction Process Parameters on the Quality ...

    African Journals Online (AJOL)

    Akorede

    for the first time the effects of extraction process parameters on the properties of parinari seed oil. The parinari seeds ... soya oil used in the production of alkyd polymer resin, a main ... relatively lower acid value implies better storage and shell life of the oil. ... Little work has been done on parinari oil, the variation in lipid.

  3. GPS User Devices Parameter Control Methods

    OpenAIRE

    Klūga, A; Kuļikovs, M; Beļinska, V; Zeļenkovs, A

    2007-01-01

    In our day’s wide assortment of GPS user devices is manufacture. How to verify that parameters of the real device corresponds to parameters that manufacture shows. How to verify that parameters have not been changed during the operation time. The last one is very important for aviation GPS systems, which must be verified before the flight, but the values of parameter in time of repair works. This work analyses GPS user devices parameters control methods.

  4. Information Extraction of High Resolution Remote Sensing Images Based on the Calculation of Optimal Segmentation Parameters

    Science.gov (United States)

    Zhu, Hongchun; Cai, Lijie; Liu, Haiying; Huang, Wei

    2016-01-01

    Multi-scale image segmentation and the selection of optimal segmentation parameters are the key processes in the object-oriented information extraction of high-resolution remote sensing images. The accuracy of remote sensing special subject information depends on this extraction. On the basis of WorldView-2 high-resolution data, the optimal segmentation parameters methodof object-oriented image segmentation and high-resolution image information extraction, the following processes were conducted in this study. Firstly, the best combination of the bands and weights was determined for the information extraction of high-resolution remote sensing image. An improved weighted mean-variance method was proposed andused to calculatethe optimal segmentation scale. Thereafter, the best shape factor parameter and compact factor parameters were computed with the use of the control variables and the combination of the heterogeneity and homogeneity indexes. Different types of image segmentation parameters were obtained according to the surface features. The high-resolution remote sensing images were multi-scale segmented with the optimal segmentation parameters. Ahierarchical network structure was established by setting the information extraction rules to achieve object-oriented information extraction. This study presents an effective and practical method that can explain expert input judgment by reproducible quantitative measurements. Furthermore the results of this procedure may be incorporated into a classification scheme. PMID:27362762

  5. Extraction of Dunham coefficients from Murrell-Sorbie parameters

    International Nuclear Information System (INIS)

    Lim Teikcheng

    2008-01-01

    A set of relationships between parameters of the Dunham and Murrell-Sorbie potential energy function is developed. By employing Taylor series expansion and comparison of terms arranged in increasing order of bond length, a set of Dunham coefficients is obtained as functions of Murrell- Sorbie parameters. The conversion functions reveal the importance of factorials in extracting Dunham coefficients from Murrell-Sorbie parameters. Plots of both functions, based on parameters of the latter, reveal good correlation near the equilibrium bond length for a group of diatomic molecules. Potential function relations, such as that shown in this paper, are useful when the preferred/reliable data is based on a potential function different from that adopted in available computational software. (orig.)

  6. Application of genetic algorithm for extraction of the parameters from powder EPR spectra

    International Nuclear Information System (INIS)

    Spalek, T.; Pietrzyk, P.; Sojka, Z.

    2005-01-01

    The application of the stochastic genetic algorithm in tandem with the deterministic Powell method to automated extraction of the magnetic parameters from powder EPR spectra was described. The efficiency and robustness of such hybrid approach were investigated as a function of the uncertainty range of parameters, using simulated data sets. The discussed results demonstrate superior performance of the hybrid genetic algorithm in fitting of complex spectra in comparison to the common Monte Carlo Method joint with the Powell refinement. (author)

  7. Quality Parameters of Curcuma Longa L. Extracts by Supercritical Fluid Extraction (SFE) and Ultrasonic Assisted Extraction (UAE)

    International Nuclear Information System (INIS)

    Zaibunnisa Abdul Haiyee; Siti Hafsah Mohd Shah; Khudzir Ismail; Nooraain Hashim; Wan Iryani Wan Ismail

    2016-01-01

    Turmeric is one of the prominently use herbal plants due to its diverse beneficial effects especially in Indian medicine. The rhizome part of the turmeric contains valuable compounds which have been said to owe its antimicrobial effects, anti-cancer, anti-inflammatory and enhance wound healing. Due to its short-life span and perishable properties, the conversion of the rhizome into turmeric extract is desirable. Several methods have been used for extraction such as Soxhlet extraction and pressurized liquid extraction (PLE). However, these techniques are tedious, laborious, time consuming and involves the usage of toxic organic solvent, of which safeness of the end product is doubtful. In this study, a rapid, reliable and green extraction method of supercritical fluid extraction (SFE) and ultrasonic assisted extraction (UAE) were used. SFE without modifier has resulted in 0.0006 mg/ 100 g of curcuminoids concentration and 5.62 % of yield (dry weight basis). UAE using ethanol was able to produce significantly the highest yield (6.40 %, dry weight basis) and the highest curcuminoids concentration (0.1020 mg/ 100 g). However, SFE was able to produce extract that contain significantly higher major volatile compounds; tumerone, ar-turmerone and curlone. Therefore, this study proves that both extraction methods were able to produce high quality turmeric extract. (author)

  8. Extracting SUSY parameters from selectron and chargino production

    International Nuclear Information System (INIS)

    Diaz, M.A.

    1997-08-01

    We review the extraction of fundamental supersymmetric parameters from experimental observables related to the detection of charginos and selectrons at e + e - colliders. We consider supergravity models with universal scalar and gaugino masses and radiatively broken electroweak symmetry. Two scenarios are considered: (a) the lightest chargino is light enough to be produced at LEP2, and (b) the right handed selectron is light enough to be produced at LEP2. We show how the validity of supergravity models can be tested even if experimental errors are large. Interesting differences between the spectrum in the two scenarios are pointed out. (author). 16 refs, 9 figs

  9. A new method for the extraction of Au(III) with ethyl thioacetoacetate into chloroform

    International Nuclear Information System (INIS)

    Khan, S.Z.; Turel, Z.R.

    1985-01-01

    A method was developed for rapid and selective extraction of Au(III) with ethyl thioacetoacetate (HETAcAc) into chloroform at pH 4. The effect of various parameters on the extraction coefficient values were studied. The substoichiometry of the extracted species of 1:3 was obtained by slope ratio and substoichiometric extraction method, respectively. (author)

  10. Virgin almond oil: Extraction methods and composition

    Energy Technology Data Exchange (ETDEWEB)

    Roncero, J.M.; Alvarez-Orti, M.; Pardo-Gimenez, A.; Gomez, R.; Rabadan, A.; Pardo, J.E.

    2016-07-01

    In this paper the extraction methods of virgin almond oil and its chemical composition are reviewed. The most common methods for obtaining oil are solvent extraction, extraction with supercritical fluids (CO2) and pressure systems (hydraulic and screw presses). The best industrial performance, but also the worst oil quality is achieved by using solvents. Oils obtained by this method cannot be considered virgin oils as they are obtained by chemical treatments. Supercritical fluid extraction results in higher quality oils but at a very high price. Extraction by pressing becomes the best option to achieve high quality oils at an affordable price. With regards chemical composition, almond oil is characterized by its low content in saturated fatty acids and the predominance of monounsaturated, especially oleic acid. Furthermore, almond oil contains antioxidants and fat-soluble bioactive compounds that make it an oil with interesting nutritional and cosmetic properties.

  11. Virgin almond oil: Extraction methods and composition

    International Nuclear Information System (INIS)

    Roncero, J.M.; Alvarez-Orti, M.; Pardo-Gimenez, A.; Gomez, R.; Rabadan, A.; Pardo, J.E.

    2016-01-01

    In this paper the extraction methods of virgin almond oil and its chemical composition are reviewed. The most common methods for obtaining oil are solvent extraction, extraction with supercritical fluids (CO2) and pressure systems (hydraulic and screw presses). The best industrial performance, but also the worst oil quality is achieved by using solvents. Oils obtained by this method cannot be considered virgin oils as they are obtained by chemical treatments. Supercritical fluid extraction results in higher quality oils but at a very high price. Extraction by pressing becomes the best option to achieve high quality oils at an affordable price. With regards chemical composition, almond oil is characterized by its low content in saturated fatty acids and the predominance of monounsaturated, especially oleic acid. Furthermore, almond oil contains antioxidants and fat-soluble bioactive compounds that make it an oil with interesting nutritional and cosmetic properties.

  12. Extraction and fusion of spectral parameters for face recognition

    Science.gov (United States)

    Boisier, B.; Billiot, B.; Abdessalem, Z.; Gouton, P.; Hardeberg, J. Y.

    2011-03-01

    Many methods have been developed in image processing for face recognition, especially in recent years with the increase of biometric technologies. However, most of these techniques are used on grayscale images acquired in the visible range of the electromagnetic spectrum. The aims of our study are to improve existing tools and to develop new methods for face recognition. The techniques used take advantage of the different spectral ranges, the visible, optical infrared and thermal infrared, by either combining them or analyzing them separately in order to extract the most appropriate information for face recognition. We also verify the consistency of several keypoints extraction techniques in the Near Infrared (NIR) and in the Visible Spectrum.

  13. Scattering-parameter extraction and calibration techniques for RF free-space material characterization

    DEFF Research Database (Denmark)

    Kaniecki, M.; Saenz, E.; Rolo, L.

    2014-01-01

    This paper demonstrates a method for material characterization (permittivity, permeability, loss tangent) based on the scattering parameters. The performance of the extraction algorithm will be shown for modelled and measured data. The measurements were carried out at the European Space Agency...

  14. Some hematological parameters of Wistar rats treated with Chromolaena odorata leave extracts

    Directory of Open Access Journals (Sweden)

    Henshaw Uchechi Okoroiwu

    2017-10-01

    Full Text Available This study was designed to investigate the effects of the different extracts of Chromolaena odorata leave on the hematopoietic system of Wistar rats. Solvent extraction was used for the ethanol and aqueous extractions while decoction method was used for the crude extraction. Fifty Wistar rats of both sexes weighing 140-180 g were used for this study. They were divided into ten groups each containing five rats. The animals were fed the extracts by oral gavage once daily for 21 days. Blood sample was collected via cardiac artery. Hematological parameters were analyzed using automation method. The ethanol extract gave the highest extract yield. The aqueous, ethanol and crude extraction had median lethal toxicity (LD50 of 2738.6 mg/kg, 1581.1 mg/kg and 224.7 mg/kg, respectively. Significant difference (P<0.05 in the total white blood cell count was observed in the 75 mg/kg ethanol and 300 mg/kg crude extracts when compared with control group. Significant difference (P<0.05 in the hemoglobin concentration was observed in the 150 mg/kg ethanol extracts when compared with the control group. Significant difference (P<0.05 in the packed cell volume was seen in the 75 mg/kg aqueous, 150 mg/kg aqueous and 75 mg/kg ethanol extracts in respect to the control group. The mean cell volume, the mean platelet volume and platelet large cell ratio of the 75 mg/kg aqueous extract were significantly different (P<0.05 when compared with the control group. The present study showed possible treatment-induced hematopoietic function of C. odorata leave extracts.

  15. EXTRACTIVE SPECTROPHOTOMETRIC METHOD FOR THE ...

    African Journals Online (AJOL)

    B. S. Chandravanshi

    The method has been applied to the analysis of carbaryl in its ... The extensive use of this insecticide poses a serious risk to both the environment and the human ... is the second most widely detected insecticide in the environmental samples ...

  16. Parameter extraction of different fuel cell models with transferred adaptive differential evolution

    International Nuclear Information System (INIS)

    Gong, Wenyin; Yan, Xuesong; Liu, Xiaobo; Cai, Zhihua

    2015-01-01

    To improve the design and control of FC (fuel cell) models, it is important to extract their unknown parameters. Generally, the parameter extraction problems of FC models can be transformed as nonlinear and multi-variable optimization problems. To extract the parameters of different FC models exactly and fast, in this paper, we propose a transferred adaptive DE (differential evolution) framework, in which the successful parameters of the adaptive DE solving previous problems are properly transferred to solve new optimization problems in the similar problem-domains. Based on this framework, an improved adaptive DE method (TRADE, in short) is presented as an illustration. To verify the performance of our proposal, TRADE is used to extract the unknown parameters of two types of fuel cell models, i.e., PEMFC (proton exchange membrane fuel cell) and SOFC (solid oxide fuel cell). The results of TRADE are also compared with those of other state-of-the-art EAs (evolutionary algorithms). Even though the modification is very simple, the results indicate that TRADE can extract the parameters of both PEMFC and SOFC models exactly and fast. Moreover, the V–I characteristics obtained by TRADE agree well with the simulated and experimental data in all cases for both types of fuel cell models. Also, it improves the performance of the original adaptive DE significantly in terms of both the quality of final solutions and the convergence speed in all cases. Additionally, TRADE is able to provide better results compared with other EAs. - Highlights: • A framework of transferred adaptive differential evolution is proposed. • Based on the framework, an improved differential evolution (TRADE) is presented. • TRADE obtains very promising results to extract the parameters of PEMFC and SOFC models

  17. Determining an Efficient Solvent Extraction Parameters for Re-Refining of Waste Lubricating Oils

    Directory of Open Access Journals (Sweden)

    Hassan Ali Durrani

    2012-04-01

    Full Text Available Re-refining of vehicle waste lubricating oil by solvent extraction is one of the efficient and cheapest methods. Three extracting solvents MEK (Methyl-Ethyl-Ketone, 1-butanol, 2-propanol were determined experimentally for their performance based on the parameters i.e. solvent type, solvent oil ratio and extraction temperature. From the experimental results it was observed the MEK performance was highest based on the lowest oil percent losses and highest sludge removal. Further, when temperature of extraction increased the oil losses percent also decreased. This is due to the solvent ability that dissolves the base oil in waste lubricating oil and determines the best SOR (Solvent Oil Ratio and extraction temperatures.

  18. Parameter extraction and estimation based on the PV panel outdoor ...

    African Journals Online (AJOL)

    The experimental data obtained are validated and compared with the estimated results obtained through simulation based on the manufacture's data sheet. The simulation is based on the Newton-Raphson iterative method in MATLAB environment. This approach aids the computation of the PV module's parameters at any ...

  19. Large-scale parameter extraction in electrocardiology models through Born approximation

    KAUST Repository

    He, Yuan

    2012-12-04

    One of the main objectives in electrocardiology is to extract physical properties of cardiac tissues from measured information on electrical activity of the heart. Mathematically, this is an inverse problem for reconstructing coefficients in electrocardiology models from partial knowledge of the solutions of the models. In this work, we consider such parameter extraction problems for two well-studied electrocardiology models: the bidomain model and the FitzHugh-Nagumo model. We propose a systematic reconstruction method based on the Born approximation of the original nonlinear inverse problem. We describe a two-step procedure that allows us to reconstruct not only perturbations of the unknowns, but also the backgrounds around which the linearization is performed. We show some numerical simulations under various conditions to demonstrate the performance of our method. We also introduce a parameterization strategy using eigenfunctions of the Laplacian operator to reduce the number of unknowns in the parameter extraction problem. © 2013 IOP Publishing Ltd.

  20. Optimization of extraction parameters of pentacyclic triterpenoids from Swertia chirata stem using response surface methodology.

    Science.gov (United States)

    Pandey, Devendra Kumar; Kaur, Prabhjot

    2018-03-01

    In the present investigation, pentacyclic triterpenoids were extracted from different parts of Swertia chirata by solid-liquid reflux extraction methods. The total pentacyclic triterpenoids (UA, OA, and BA) in extracted samples were determined by HPTLC method. Preliminary studies showed that stem part contains the maximum pentacyclic triterpenoid and was chosen for further studies. Response surface methodology (RSM) has been employed successfully by solid-liquid reflux extraction methods for the optimization of different extraction variables viz., temperature ( X 1 35-70 °C), extraction time ( X 2 30-60 min), solvent composition ( X 3 20-80%), solvent-to-solid ratio ( X 4 30-60 mlg -1 ), and particle size ( X 5 3-6 mm) on maximum recovery of triterpenoid from stem parts of Swertia chirata . A Plackett-Burman design has been used initially to screen out the three extraction factors viz., particle size, temperature, and solvent composition on yield of triterpenoid. Moreover, central composite design (CCD) was implemented to optimize the significant extraction parameters for maximum triterpenoid yield. Three extraction parameters viz., mean particle size (3 mm), temperature (65 °C), and methanol-ethyl acetate solvent composition (45%) can be considered as significant for the better yield of triterpenoid A second-order polynomial model satisfactorily fitted the experimental data with the R 2 values of 0.98 for the triterpenoid yield ( p  < 0.001), implying good agreement between the experimental triterpenoid yield (3.71%) to the predicted value (3.79%).

  1. Simulation-based Extraction of Key Material Parameters from Atomic Force Microscopy

    Science.gov (United States)

    Alsafi, Huseen; Peninngton, Gray

    Models for the atomic force microscopy (AFM) tip and sample interaction contain numerous material parameters that are often poorly known. This is especially true when dealing with novel material systems or when imaging samples that are exposed to complicated interactions with the local environment. In this work we use Monte Carlo methods to extract sample material parameters from the experimental AFM analysis of a test sample. The parameterized theoretical model that we use is based on the Virtual Environment for Dynamic AFM (VEDA) [1]. The extracted material parameters are then compared with the accepted values for our test sample. Using this procedure, we suggest a method that can be used to successfully determine unknown material properties in novel and complicated material systems. We acknowledge Fisher Endowment Grant support from the Jess and Mildred Fisher College of Science and Mathematics,Towson University.

  2. Penalty parameter of the penalty function method

    DEFF Research Database (Denmark)

    Si, Cheng Yong; Lan, Tian; Hu, Junjie

    2014-01-01

    The penalty parameter of penalty function method is systematically analyzed and discussed. For the problem that Deb's feasibility-based rule doesnot give the detailed instruction as how to rank two solutions when they have the same constraint violation, an improved Deb's feasibility-based rule is...

  3. A critical discussion of the extraction of the {rho} - parameter at high energy hadron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Nicolescu, B. [Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire

    1996-12-31

    A new and general method is proposed for the extraction of the semi theoretical {rho}-parameter from the raw dN/dt data. By using this method it is shown that the exponential form of the hadron amplitude in the diffraction peak at high energy is doubtful and that the value {rho} = 0.135 {+-} 0.015, extracted from the very precise UA4/2 dN/dt data at {radical}s 541 GeV, is probably wrong. (author) 4 refs.

  4. Extraction of bowing parameters from violin performance combining motion capture and sensors.

    Science.gov (United States)

    Schoonderwaldt, E; Demoucron, M

    2009-11-01

    A method is described for measurement of a complete set of bowing parameters in violin performance. Optical motion capture was combined with sensors for accurate measurement of the main bowing parameters (bow position, bow velocity, bow acceleration, bow-bridge distance, and bow force) as well as secondary control parameters (skewness, inclination, and tilt of the bow). In addition, other performance features (moments of on/off in bow-string contact, string played, and bowing direction) were extracted. Detailed descriptions of the calculations of the bowing parameters, features, and calibrations are given. The described system is capable of measuring all bowing parameters without disturbing the player, allowing for detailed studies of musically relevant aspects of bow control and coordination of bowing parameters in bowed-string instrument performance.

  5. OPTIMIZATION OF DYEING PARAMETERS TO DYE COTTON WITH CARROT EXTRACTION

    Directory of Open Access Journals (Sweden)

    MIRALLES Verónica

    2017-05-01

    Full Text Available Natural dyes derived from flora and fauna are believed to be safe because of non-toxic, non-carcinogenic and biodegradable nature. Furthermore, natural dyes do not cause pollution and waste water problems. Natural dyes as well as synthetic dyes need the optimum parameters to get a good dyeing. On some occasions, It is necessary the use of mordants to increase the affinity between cellulose fiber and natural dye, but there are other conditions to optimize in the dyeing process, like time, temperature, auxiliary porducts, etc. In addition, the optimum conditions are different depends on the type of dye and the fiber nature. The aim of this work is the use of carrot extract to dye cotton fabric by exhaustion at diverse dyeing conditions. Diffferent dyeing processes were carried out to study the effect of pH condition and the temperature, using 7, 6 and 4 pH values and 95 ºC and 130ºC for an hour. As a result some images of dyed samples are shown. Moreover, to evaluate the colour of each sample CIELAB parameters are analysed obtained by reflexion spectrophotometre. The results showed that the temperature used has an important influence on the colour of the dyed sample.

  6. Newer methods of extraction of teeth

    Directory of Open Access Journals (Sweden)

    MHendra Chandha

    2016-06-01

    Full Text Available Atraumatic extraction methods are deemed to be important to minimize alveolar bone loss after tooth extraction. With the advent of such techniques, exodontia is no more a dreaded procedure in anxious patients. Newer system and techniques for extraction of teeth have evolved in the recent few decades. This article reviews and discusses new techniques to make simple and complex exodontias more efficient with improved patient outcomes. This includes physics forceps, powered periotome, piezosurgery, benex extractor, sonic instrument for bone surgery, lasers.

  7. Methods for determination of extractable complex composition

    International Nuclear Information System (INIS)

    Sergievskij, V.V.

    1984-01-01

    Specific features and restrictions of main methods for determining the extractable complex composition by the distribution data (methods of equilibrium shift, saturation, mathematical models) are considered. Special attention is given to the solution of inverse problems with account for hydration effect on the activity of organic phase components. By example of the systems lithium halides-isoamyl alcohol, thorium nitrate-n-hexyl alcohol, mineral acids tri-n-butyl phosphate (TBP), metal nitrates (uranium lanthanides) - TBP the results on determining stoichiometry of extraction equilibria obtained by various methods are compared

  8. Method for Determining the Time Parameter

    Directory of Open Access Journals (Sweden)

    K. P. Baslyk

    2014-01-01

    Full Text Available This article proposes a method for calculating one of the characteristics that represents the flight program of the first stage of ballistic rocket i.e. time parameter of the program of attack angle.In simulation of placing the payload for the first stage, a program of flight is used which consists of three segments, namely a vertical climb of the rocket, a segment of programmed reversal by attack angle, and a segment of gravitational reversal with zero angle of attack.The programed reversal by attack angle is simulated as a rapidly decreasing and increasing function. This function depends on the attack angle amplitude, time and time parameter.If the projected and ballistic parameters and the amplitude of attack angle were determined this coefficient is calculated based the constraint that the rocket velocity is equal to 0.8 from the sound velocity (0,264 km/sec when the angle of attack becomes equal to zero. Such constraint is transformed to the nonlinear equation, which can be solved using a Newton method.The attack angle amplitude value is unknown for the design analysis. Exceeding some maximum admissible value for this parameter may lead to excessive trajectory collapsing (foreshortening, which can be identified as an arising negative trajectory angle.Consequently, therefore it is necessary to compute the maximum value of the attack angle amplitude with the following constraints: a trajectory angle is positive during the entire first stage flight and the rocket velocity is equal to 0,264 km/sec by the end of program of angle attack. The problem can be formulated as a task of the nonlinear programming, minimization of the modified Lagrange function, which is solved using the multipliers method.If multipliers and penalty parameter are constant the optimization problem without constraints takes place. Using the determined coordinate descent method allows solving the problem of modified Lagrange function of unconstrained minimization with fixed

  9. Extraction of diode parameters of silicon solar cells under high illumination conditions

    International Nuclear Information System (INIS)

    Khan, Firoz; Baek, Seong-Ho; Park, Yiseul; Kim, Jae Hyun

    2013-01-01

    Graphical abstract: We have developed an analytical method to determine the diode parameters of concentrator solar cells under high illumination conditions. The determined values of diode parameters have been used to compute the theoretical values of performance parameters. The computed values of the open circuit voltage, curve factor, and efficiency obtained using diode parameters determined with this method showed good agreement (<2% discrepancy) with their experimental values in the temperature range 298–323 K. Highlights: • An analytical method to extract the diode parameters of concentrated Si solar cells. • This method uses single I–V curve under high illumination conditions. • The theoretical values of performance parameters have been computed. • Theoretical values of parameters matched within 2% discrepancy limit. • This method gives best results among the methods used in this work. - Abstract: An analytical method has been developed to extract all four diode parameters, namely the shunt resistance, series resistance, diode ideality factor, and reverse saturation current density, using a single J–V curve, based on one exponential model of silicon solar cells under high illumination conditions. The slope of the J–V curve (dV/dJ) at a short circuit condition is used to determine the value of the shunt resistance. The slope of the J–V curve at an open circuit condition together with the short circuit current density, open circuit voltage, current density, and voltage at maximum power point have been used to determine the values of the series resistance, diode ideality factor, and reverse saturation current density. The determined values of the diode parameters have been used to compute the theoretical values of the open circuit voltage, curve factor, and efficiency of the solar cell. The theoretical J–V curves matched well with the corresponding experimental curves. This method is applied to determine the diode parameters of concentrator

  10. Fast non-linear extraction of plasma equilibrium parameters using a neural network mapping

    International Nuclear Information System (INIS)

    Lister, J.B.; Schnurrenberger, H.

    1990-07-01

    The shaping of non-circular plasmas requires a non-linear mapping between the measured diagnostic signals and selected equilibrium parameters. The particular configuration of Neural Network known as the multi-layer perceptron provides a powerful and general technique for formulating an arbitrary continuous non-linear multi-dimensional mapping. This technique has been successfully applied to the extraction of equilibrium parameters from measurements of single-null diverted plasmas in the DIII-D tokamak; the results are compared with a purely linear mapping. The method is promising, and hardware implementation is straightforward. (author) 15 refs., 7 figs

  11. Fast non-linear extraction of plasma equilibrium parameters using a neural network mapping

    International Nuclear Information System (INIS)

    Lister, J.B.; Schnurrenberger, H.

    1991-01-01

    The shaping of non-circular plasmas requires a non-linear mapping between the measured diagnostic signals and selected equilibrium parameters. The particular configuration of neural network known as the multilayer perceptron provides a powerful and general technique for formulating an arbitrary continuous non-linear multi-dimensional mapping. This technique has been successfully applied to the extraction of equilibrium parameters from measurements of single-null diverted plasmas in the DIII-D tokamak; the results are compared with a purely linear mapping. The method is promising, and hardware implementation is straightforward. (author). 17 refs, 8 figs, 2 tab

  12. A fast, simple and green method for the extraction of carbamate pesticides from rice by microwave assisted steam extraction coupled with solid phase extraction.

    Science.gov (United States)

    Song, Weitao; Zhang, Yiqun; Li, Guijie; Chen, Haiyan; Wang, Hui; Zhao, Qi; He, Dong; Zhao, Chun; Ding, Lan

    2014-01-15

    This paper presented a fast, simple and green sample pretreatment method for the extraction of 8 carbamate pesticides in rice. The carbamate pesticides were extracted by microwave assisted water steam extraction method, and the extract obtained was immediately applied on a C18 solid phase extraction cartridge for clean-up and concentration. The eluate containing target compounds was finally analysed by high performance liquid chromatography with mass spectrometry. The parameters affecting extraction efficiency were investigated and optimised. The limits of detection ranging from 1.1 to 4.2ngg(-1) were obtained. The recoveries of 8 carbamate pesticides ranged from 66% to 117% at three spiked levels, and the inter- and intra-day relative standard deviation values were less than 9.1%. Compared with traditional methods, the proposed method cost less extraction time and organic solvent. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Zener Diode Compact Model Parameter Extraction Using Xyce-Dakota Optimization.

    Energy Technology Data Exchange (ETDEWEB)

    Buchheit, Thomas E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wilcox, Ian Zachary [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sandoval, Andrew J [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reza, Shahed [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-12-01

    This report presents a detailed process for compact model parameter extraction for DC circuit Zener diodes. Following the traditional approach of Zener diode parameter extraction, circuit model representation is defined and then used to capture the different operational regions of a real diode's electrical behavior. The circuit model contains 9 parameters represented by resistors and characteristic diodes as circuit model elements. The process of initial parameter extraction, the identification of parameter values for the circuit model elements, is presented in a way that isolates the dependencies between certain electrical parameters and highlights both the empirical nature of the extraction and portions of the real diode physical behavior which of the parameters are intended to represent. Optimization of the parameters, a necessary part of a robost parameter extraction process, is demonstrated using a 'Xyce-Dakota' workflow, discussed in more detail in the report. Among other realizations during this systematic approach of electrical model parameter extraction, non-physical solutions are possible and can be difficult to avoid because of the interdependencies between the different parameters. The process steps described are fairly general and can be leveraged for other types of semiconductor device model extractions. Also included in the report are recommendations for experiment setups for generating optimum dataset for model extraction and the Parameter Identification and Ranking Table (PIRT) for Zener diodes.

  14. Parameter-free extraction of EMCD from an energy-filtered diffraction datacube using multivariate curve resolution

    International Nuclear Information System (INIS)

    Muto, S.; Tatsumi, K.; Rusz, J.

    2013-01-01

    We present a parameter-free method of extraction of the electron magnetic circular dichroism spectra from energy-filtered diffraction patterns measured on a crystalline specimen. The method is based on a multivariate curve resolution technique. The main advantage of the proposed method is that it allows extraction of the magnetic signal regardless of the symmetry and orientation of the crystal, as long as there is a sufficiently strong magnetic component of the signal in the diffraction plane. This method essentially overcomes difficulties in extraction of the EMCD signal caused by complexity of dynamical diffraction effects. - Highlights: ► New method of extraction of EMCD signal using statistical methods (multivariate curve resolution). ► EMCD can be extracted quantitatively regardless of symmetry of crystal or its orientation. ► First principles simulation of EFDIF datacube, including dynamical diffraction effects

  15. Effects of Phytolacca dodecandra Extracts on the Quality Parameters ...

    African Journals Online (AJOL)

    P. dodecandra extracts for use as biopesticide are recommended as a sustainable alternative to synthetic pesticides in maize grains storage especially for the subsistence farmers. However, further tests on biosafety and effects of the extracts on the organoleptic contents of the grains prior to consumption are recommended.

  16. Multivariate analysis and extraction of parameters in resistive RAMs using the Quantum Point Contact model

    Science.gov (United States)

    Roldán, J. B.; Miranda, E.; González-Cordero, G.; García-Fernández, P.; Romero-Zaliz, R.; González-Rodelas, P.; Aguilera, A. M.; González, M. B.; Jiménez-Molinos, F.

    2018-01-01

    A multivariate analysis of the parameters that characterize the reset process in Resistive Random Access Memory (RRAM) has been performed. The different correlations obtained can help to shed light on the current components that contribute in the Low Resistance State (LRS) of the technology considered. In addition, a screening method for the Quantum Point Contact (QPC) current component is presented. For this purpose, the second derivative of the current has been obtained using a novel numerical method which allows determining the QPC model parameters. Once the procedure is completed, a whole Resistive Switching (RS) series of thousands of curves is studied by means of a genetic algorithm. The extracted QPC parameter distributions are characterized in depth to get information about the filamentary pathways associated with LRS in the low voltage conduction regime.

  17. THE FACE EXTRACTION METHOD FOR MOBILE DEVICES

    Directory of Open Access Journals (Sweden)

    Viktor Borodin

    2013-10-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 The problem of automatic face recognition on images is considered. The method of face ellipse extraction from photo and methods for face special points extraction are proposed /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Обычная таблица"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;}

  18. Effects of Phytolacca dodecandra Extracts on the Quality Parameters ...

    African Journals Online (AJOL)

    SARAH

    2017-04-30

    Apr 30, 2017 ... extracts minimized grain damage to <5% and <6%, respectively after 150 days post treatment. ..... that produce mycotoxins (Suleiman et al., 2013). The .... 'An ASABE meeting presentation', done in. Kansas,. City,. Missouri,.

  19. Method for Extracting and Sequestering Carbon Dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Rau, Gregory H.; Caldeira, Kenneth G.

    2005-05-10

    A method and apparatus to extract and sequester carbon dioxide (CO2) from a stream or volume of gas wherein said method and apparatus hydrates CO2, and reacts the resulting carbonic acid with carbonate. Suitable carbonates include, but are not limited to, carbonates of alkali metals and alkaline earth metals, preferably carbonates of calcium and magnesium. Waste products are metal cations and bicarbonate in solution or dehydrated metal salts, which when disposed of in a large body of water provide an effective way of sequestering CO2 from a gaseous environment.

  20. Extraction of optical scattering parameters and attenuation compensation in optical coherence tomography images of multi-layered tissue structures

    DEFF Research Database (Denmark)

    Thrane, Lars; Frosz, Michael Henoch; Tycho, Andreas

    2004-01-01

    A recently developed analytical optical coherence tomography (OCT) model [Thrane et al., J. Opt. Soc. Am. A 17, 484 (2000)] allows the extraction of optical scattering parameters from OCT images, thereby permitting attenuation compensation in those images. By expanding this theoretical model, we...... have developed a new method for extracting optical scattering parameters from multilayered tissue structures in vivo. To verify this, we used a Monte Carlo (MC) OCT model as a numerical phantom to simulate the OCT signal for het-erogeneous multilayered tissue. Excellent agreement between the extracted......, and the results hold promise for expanding the functional imaging capabilities of OCT....

  1. Evaluation and Optimization of Downstream Process Parameters for Extraction of Betulinic Acid from the Bark of Ziziphus jujubae L.

    Directory of Open Access Journals (Sweden)

    Kashyap Kumar Dubey

    2013-01-01

    Full Text Available Present work investigated an apposite and efficient method for extraction of betulinic acid (BA from the bark of Ziziphus jujubae. Various extraction methods like stirring extraction, soxhlet extraction, ultrasonic extraction, and microwave assisted extraction (MAE were evaluated for increasing recovery percentage of BA. From the raffinate so obtained, BA was isolated. Thin layer chromatography (TLC was used to analyze the extract and high performance liquid chromatography (HPLC for quantification. The results revealed that the percentage extraction of BA from Z. jujubae by MAE was more proficient. As recovery percentage of BA by MAE technique turned out to be maximum, by using response surface methodology (RSM, three process parameters (pH, temperature, and time were optimized by MAE and it was observed that the optimum parameters (pH 6.5, temp. 70.23°C, and time 3.5 min gave the maximum recovery of BA (0.44% w/w. To validate the RSM model, experiments were performed and the highest recovery of BA was found to be 0.4% w/w which is ±0.04% to the predicted value. Henceforth the extraction efficiency and the substantial saving of time by MAE was more capable than the other extraction techniques.

  2. Simple, miniaturized blood plasma extraction method.

    Science.gov (United States)

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to

  3. Influence of extraction methods on the hepatotoxicity of Azadirachta ...

    African Journals Online (AJOL)

    The influence of extraction methods: Cold aqueous (CA) hot aqueous (HA) and alcoholic extraction (AE) methods on the hepatotoxic effect of Azadirachta indica bark extract (ABC) was investigated using albino rats. A total of forty eight rats were divided into three groups of sixteen rats equally for the extraction methods.

  4. Development of the morphing method for signal modelling and parameter extraction from ATLAS data, using effective operators in the H → W{sup +}W{sup -} → l{sup +}νl{sup -} anti ν process

    Energy Technology Data Exchange (ETDEWEB)

    Burgard, Carsten; Koeneke, Karsten [Physikalisches Institut, Albert-Ludwigs-Universitaet Freiburg (Germany)

    2016-07-01

    Given the parameter space of all physically conceivable Lagrange operators connected to physics beyond the Standard Model in the Higgs-boson sector, it seems unfeasible to conduct dedicated analyses for every new scenario. Instead, a fast, continuous, and analytical method of signal modelling would not only help to conduct hypothesis tests more efficiently, but would also allow to directly measure and derive limits on the coefficients of the individual terms in the matrix element. Similar approaches, such as Matrix-Element-Reweighting can not only be outperformed significantly by the morphing technique for some applications, but also be used complementarily and in conjunction with this new approach. This talk explores the applications in the context of effective Lagrangians for analyses of Higgs bosons decaying into two vector bosons for leptonic final states.

  5. Highly efficient micellar extraction of toxic picric acid into novel ionic liquid: Effect of parameters, solubilization isotherm, evaluation of thermodynamics and design parameters

    Energy Technology Data Exchange (ETDEWEB)

    Bhatt, Darshak R.; Maheria, Kalpana C. [Applied Chemistry Department, Sardar Vallabhbhai National Institute of Technology, Surat 395007, Gujarat (India); Parikh, Jigisha K., E-mail: jk_parikh@yahoo.co.in [Chemical Engineering Department, Sardar Vallabhbhai National Institute of Technology, Surat 395007, Gujarat (India)

    2015-12-30

    Highlights: • Picric acid is a toxic compound. • DIL significantly improves CPE efficiency of PA. • Higher extraction efficiency obtained in both nearly neutral and acidic condition. • The extraction process – spontaneous and endothermic in nature. - Abstract: A simple and new approach in cloud point extraction (CPE) method was developed for removal of picric acid (PA) by the addition of N,N,N,N’,N’,N’-hexaethyl-ethane-1,2-diammonium dibromide ionic liquid (IL) in non-ionic surfactant Triton X-114 (TX-114). A significant increase in extraction efficiency was found upon the addition of dicationic ionic liquid (DIL) at both nearly neutral and high acidic pH. The effects of different operating parameters such as pH, temperature, time, concentration of surfactant, PA and DIL on extraction of PA were investigated and optimum conditions were established. The extraction mechanism was also proposed. A developed Langmuir isotherm was used to compute the feed surfactant concentration required for the removal of PA up to an extraction efficiency of 90%. The effects of temperature and concentration of surfactant on various thermodynamic parameters were examined. It was found that the values of ΔG° increased with temperature and decreased with surfactant concentration. The values of ΔH° and ΔS° increased with surfactant concentration. The developed approach for DIL mediated CPE has proved to be an efficient and green route for extraction of PA from water sample.

  6. Local device parameter extraction of a concentrator photovoltaic cell under solar spot illumination

    Energy Technology Data Exchange (ETDEWEB)

    Munji, M.K.; Okullo, W.; van Dyk, E.E.; Vorster, F.J. [Physics Department, Nelson Mandela Metropolitan University, P O Box 77000, Port Elizabeth 6031 (South Africa)

    2010-12-15

    Focused sunlight can act as a localized source of excess minority carriers in a solar cell. Current signal generated by these carriers gives considerable information about the electrical properties of the cell's material. Point by point current-voltage data were measured for a back point-contact concentrator photovoltaic cell when illuminated by focused sunlight. Two numerical curve fitting procedures: a non-linear two-point interval division and particle swarm optimization algorithm were then applied to extract local parameters (i.e. as function of position) from the current-voltage data at each measurement point. Extracted parameters plotted yields relative spatial information about the electrical properties of a solar cell in a two or three dimensional mapping. The curve fitting routines applied to current-voltage data reveal that performance parameters: short circuit current, open circuit voltage, maximum power and fill factor show distinct variations in the vicinity of the observed current reducing feature. The relative values of the diode ideality factors, series resistance, shunt resistance and reverse saturation currents from both methods showed no significant measurable features that could be distinguished. This shows that the observed reduction in photo-induced current was due to severe recombination in the bulk or around the highly diffused point contacts and not the quality of the multiple p-n junctions of the cell. These approaches allow one to obtain a set of parameters at each local point on the cell which are reasonable and representative of the physical system. (author)

  7. Optimization design and application of composite ultrasonic extraction method for effective constituents of green tea

    Directory of Open Access Journals (Sweden)

    Cheng-Chi Wang

    2015-12-01

    Full Text Available A composite ultrasonic process is used to extract five constituent components of green tea, namely caffeine, catechin, epigallocatechin gallate, epicatechin, and chlorogenic acid. The optimal parameters of the extraction process are determined using the robust Taguchi design method. The extracted products are analyzed using gas chromatography and high-performance liquid chromatography. The experimental results confirm the effectiveness of the proposed ultrasonic technique in extracting the components of interest. Moreover, it is shown that the optimal extraction parameters depend on the particular component. In general, the present findings provide a useful reference for further research on the processing of green tea.

  8. Applications of the Automated SMAC Modal Parameter Extraction Package

    International Nuclear Information System (INIS)

    MAYES, RANDALL L.; DORRELL, LARRY R.; KLENKE, SCOTT E.

    1999-01-01

    An algorithm known as SMAC (Synthesize Modes And Correlate), based on principles of modal filtering, has been in development for a few years. The new capabilities of the automated version are demonstrated on test data from a complex shell/payload system. Examples of extractions from impact and shaker data are shown. The automated algorithm extracts 30 to 50 modes in the bandwidth from each column of the frequency response function matrix. Examples of the synthesized Mode Indicator Functions (MIFs) compared with the actual MIFs show the accuracy of the technique. A data set for one input and 170 accelerometer outputs can typically be reduced in an hour. Application to a test with some complex modes is also demonstrated

  9. The fitting parameters extraction of conversion model of the low dose rate effect in bipolar devices

    International Nuclear Information System (INIS)

    Bakerenkov, Alexander

    2011-01-01

    The Enhanced Low Dose Rate Sensitivity (ELDRS) in bipolar devices consists of in base current degradation of NPN and PNP transistors increase as the dose rate is decreased. As a result of almost 20-year studying, the some physical models of effect are developed, being described in detail. Accelerated test methods, based on these models use in standards. The conversion model of the effect, that allows to describe the inverse S-shaped excess base current dependence versus dose rate, was proposed. This paper presents the problem of conversion model fitting parameters extraction.

  10. A comparison of five extraction methods for extracellular polymeric ...

    African Journals Online (AJOL)

    Two physical methods (centrifugation and ultrasonication) and 3 chemical methods (extraction with EDTA, extraction with formaldehyde, and extraction with formaldehyde plus NaOH) for extraction of EPS from alga-bacteria biofilm were assessed. Pretreatment with ultrasound at low intensity doubled the EPS yield without ...

  11. Parameter tracking with partial forgetting method

    Czech Academy of Sciences Publication Activity Database

    Dedecius, Kamil; Nagy, Ivan; Kárný, Miroslav

    2012-01-01

    Roč. 26, č. 1 (2012), s. 1-12 ISSN 0890-6327 R&D Projects: GA ČR GA102/08/0567 Institutional research plan: CEZ:AV0Z10750506 Keywords : regression models * model * parameter estimation * parameter tracking Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 1.219, year: 2012 http://library.utia.cas.cz/separaty/2012/AS/dedecius-0370448.pdf

  12. parameter extraction and estimation based on the pv panel outdoor

    African Journals Online (AJOL)

    userpc

    The five parameters in Equation (1) depend on the incident solar irradiance, the cell temperature, and on their reference values. These reference values are generally provided by manufacturers of PV modules for specified operating condition such as STC (Standard Test Conditions) for which the irradiance is 1000 and the.

  13. Parameter extraction using global particle swarm optimization approach and the influence of polymer processing temperature on the solar cell parameters

    Science.gov (United States)

    Kumar, S.; Singh, A.; Dhar, A.

    2017-08-01

    The accurate estimation of the photovoltaic parameters is fundamental to gain an insight of the physical processes occurring inside a photovoltaic device and thereby to optimize its design, fabrication processes, and quality. A simulative approach of accurately determining the device parameters is crucial for cell array and module simulation when applied in practical on-field applications. In this work, we have developed a global particle swarm optimization (GPSO) approach to estimate the different solar cell parameters viz., ideality factor (η), short circuit current (Isc), open circuit voltage (Voc), shunt resistant (Rsh), and series resistance (Rs) with wide a search range of over ±100 % for each model parameter. After validating the accurateness and global search power of the proposed approach with synthetic and noisy data, we applied the technique to the extract the PV parameters of ZnO/PCDTBT based hybrid solar cells (HSCs) prepared under different annealing conditions. Further, we examine the variation of extracted model parameters to unveil the physical processes occurring when different annealing temperatures are employed during the device fabrication and establish the role of improved charge transport in polymer films from independent FET measurements. The evolution of surface morphology, optical absorption, and chemical compositional behaviour of PCDTBT co-polymer films as a function of processing temperature has also been captured in the study and correlated with the findings from the PV parameters extracted using GPSO approach.

  14. A comparative study of Averrhoabilimbi extraction method

    Science.gov (United States)

    Zulhaimi, H. I.; Rosli, I. R.; Kasim, K. F.; Akmal, H. Muhammad; Nuradibah, M. A.; Sam, S. T.

    2017-09-01

    In recent year, bioactive compound in plant has become a limelight in the food and pharmaceutical market, leading to research interest to implement effective technologies for extracting bioactive substance. Therefore, this study is focusing on extraction of Averrhoabilimbi by different extraction technique namely, maceration and ultrasound-assisted extraction. Fewplant partsof Averrhoabilimbiweretaken as extraction samples which are fruits, leaves and twig. Different solvents such as methanol, ethanol and distilled water were utilized in the process. Fruit extractsresult in highest extraction yield compared to other plant parts. Ethanol and distilled water have significant role compared to methanol in all parts and both extraction technique. The result also shows that ultrasound-assisted extraction gave comparable result with maceration. Besides, the shorter period on extraction process gives useful in term of implementation to industries.

  15. Comparison of clinical parameters and environmental noise levels between regular surgery and piezosurgery for extraction of impacted third molars

    OpenAIRE

    Chang, Hao-Hueng; Lee, Ming-Shu; Hsu, You-Chyun; Tsai, Shang-Jye; Lin, Chun-Pin

    2015-01-01

    Impacted third molars can be extracted by regular surgery or piezosurgery. The aim of this study was to compare clinical parameters and device-produced noise levels between regular surgery and piezosurgery for the extraction of impacted third molars. Methods: Twenty patients (18 women and 2 men, 17–29 years of age) with bilateral symmetrical impacted mandibular or maxillary third molars of the same level were included in this randomized crossover clinical trial. The 40 impacted third molar...

  16. Power extraction calculation improvement when local parameters are included

    Science.gov (United States)

    Flores-Mateos, L. M.; Hartnett, M.

    2016-02-01

    The improvement of the tidal resource assessment will be studied by comparing two approaches in a two-dimensional, finite difference, hydrodynamic model DIVAST-ADI; in a channel of non-varying cross-sectional area that connects two large basins. The first strategy, considers a constant trust coefficient; the second one, use the local field parameters around the turbine. These parameters are obtained after applying the open channel theory in the tidal stream and after considering the turbine as a linear momentum actuator disk. The parameters correspond to the upstream and downstream, with respect to the turbine, speeds and depths; also the blockage ratio, the wake velocity and the bypass coefficients and they have already been incorporated in the model. The figure (a) shows the numerical configuration at high tide developed with DIVAST-ADI. The experiment undertakes two open boundary conditions. The first one is a sinusoidal forcing introduced as a water level located at (I, J=1) and the second one, indicate that a zero velocity and a constant water depth were kept (I, J=362); when the turbine is introduced it is placed in the middle of the channel (I=161, J=181). The influence of the turbine in the velocity and elevation around the turbine region is evident; figure (b) and (c) shows that the turbine produces a discontinuity in the depth and velocity profile, when we plot a transect along the channel. Finally, the configuration implemented reproduced with satisfactory accuracy the quasi-steady flow condition, even without presenting shock-capturing capability. Also, the range of the parameters 0.01<α 4<0.55, $0

  17. Robust parameter extraction for decision support using multimodal intensive care data

    Science.gov (United States)

    Clifford, G.D.; Long, W.J.; Moody, G.B.; Szolovits, P.

    2008-01-01

    Digital information flow within the intensive care unit (ICU) continues to grow, with advances in technology and computational biology. Recent developments in the integration and archiving of these data have resulted in new opportunities for data analysis and clinical feedback. New problems associated with ICU databases have also arisen. ICU data are high-dimensional, often sparse, asynchronous and irregularly sampled, as well as being non-stationary, noisy and subject to frequent exogenous perturbations by clinical staff. Relationships between different physiological parameters are usually nonlinear (except within restricted ranges), and the equipment used to measure the observables is often inherently error-prone and biased. The prior probabilities associated with an individual's genetics, pre-existing conditions, lifestyle and ongoing medical treatment all affect prediction and classification accuracy. In this paper, we describe some of the key problems and associated methods that hold promise for robust parameter extraction and data fusion for use in clinical decision support in the ICU. PMID:18936019

  18. Artificial Intelligence Methods Applied to Parameter Detection of Atrial Fibrillation

    Science.gov (United States)

    Arotaritei, D.; Rotariu, C.

    2015-09-01

    In this paper we present a novel method to develop an atrial fibrillation (AF) based on statistical descriptors and hybrid neuro-fuzzy and crisp system. The inference of system produce rules of type if-then-else that care extracted to construct a binary decision system: normal of atrial fibrillation. We use TPR (Turning Point Ratio), SE (Shannon Entropy) and RMSSD (Root Mean Square of Successive Differences) along with a new descriptor, Teager- Kaiser energy, in order to improve the accuracy of detection. The descriptors are calculated over a sliding window that produce very large number of vectors (massive dataset) used by classifier. The length of window is a crisp descriptor meanwhile the rest of descriptors are interval-valued type. The parameters of hybrid system are adapted using Genetic Algorithm (GA) algorithm with fitness single objective target: highest values for sensibility and sensitivity. The rules are extracted and they are part of the decision system. The proposed method was tested using the Physionet MIT-BIH Atrial Fibrillation Database and the experimental results revealed a good accuracy of AF detection in terms of sensitivity and specificity (above 90%).

  19. On extracting heavy quark parameters from moments with cuts

    International Nuclear Information System (INIS)

    Bigi, I.I.; Uraltsev, N.

    2004-01-01

    We point out that the moments of the photon energy spectrum in B→X s +γ decays have a significant bias compared to the OPE expressions used to evaluate them, when a lower cut on the photon energy is imposed. This typically increases the value extracted for the apparent b quark mass by 70 MeV or more together with an even more dramatic reduction in the apparent value of the kinetic energy expectation value. These nonperturbative effects are exponential in the effective hardness of the transition, which is strongly lowered by high cuts, and do not reflect a breakdown of the 1/m b expansion itself. Similar effects in semileptonic b→c decays are briefly addressed. Accounting for the cut-related shifts brings different measurements into good agreement, when the OPE-based theory employs the 'robust' approach. We stress the utility of the second moment of E γ , once the aforementioned effects have been included

  20. Novel Approaches to Extraction Methods in Recovery of Capsaicin from Habanero Pepper (CNPH 15.192).

    Science.gov (United States)

    Martins, Frederico S; Borges, Leonardo L; Ribeiro, Claudia S C; Reifschneider, Francisco J B; Conceição, Edemilson C

    2017-07-01

    The objective of this study was to compare three capsaicin extraction methods: Shoxlet, Ultrasound-assisted Extraction (UAE), and Shaker-assisted Extraction (SAE) from Habanero pepper, CNPH 15.192. The different parameters evaluated were alcohol degree, time extraction, and solid-solvent ratio using response surface methodology (RSM). The three parameters found significant ( p Soxhlet increased the extraction in 10-25%; however, long extraction times (45 minutes) degraded 2% capsaicin. The extraction of capsaicin was influenced by extraction method and by the operating conditions chosen. The optimized conditions provided savings of time, solvent, and herbal material. Prudent choice of the extraction method is essential to ensure optimal yield of extract, thereby making the study relevant and the knowledge gained useful for further exploitation and application of this resource. Habanero pepper , line CNPH 15.192, possess capsaicin in higher levels when compared with others speciesHigher levels of ethanolic strength are more suitable to obtain a higher levels of capsaicinBox-Behnken design indicates to be useful to explore the best conditions of ultrasound assisted extraction of capsaicin. Abbreviations used: Nomenclature UAE: Ultrasound-assisted Extraction; SAE: Shaker-assisted Extraction.

  1. Variations of the bacterial foraging algorithm for the extraction of PV module parameters from nameplate data

    International Nuclear Information System (INIS)

    Awadallah, Mohamed A.

    2016-01-01

    Highlights: • Bacterial foraging algorithm is used to extract PV model parameters from nameplate data. • Five variations of the bacterial foraging algorithm are compared on a simple objective function. • Best results obtained when swarming is neglected, step size is varied, and global best is preserved. • The technique is successfully applied on single- and double-diode models. • Matching between computation and measurements validates the obtained set of parameters. - Abstract: The paper introduces the task of parameter extraction of photovoltaic (PV) modules as a nonlinear optimization problem. The concerned parameters are the series resistance, shunt resistance, diode ideality factor, and diode reverse saturation current for both the single- and double-diode models. An error function representing the mismatch between computed and targeted performance is minimized using different versions of the bacterial foraging (BF) algorithm of global search and heuristic optimization. The targeted performance is obtained from the nameplate data of the PV module. Five distinct variations of the BF algorithm are used to solve the problem independently for the single- and double-diode models. The best optimization results are obtained when swarming is eliminated, chemotactic step size is dynamically varied, and global best is preserved, all acting together. Under such conditions, the best global minimum of 0.0028 is reached in an average best time of 94.4 sec for the single-diode model. However, it takes an average of 153 sec to reach the best global minimum of 0.0021 in case of double-diode model. An experimental verification study involves the comparison of computed performance to measurements on an Eclipsall PV module. It is shown that all variants of the BF algorithm could reach equivalent-circuit parameters with accepted accuracy by solving the optimization problem. The good matching between analytical and experimental results indicates the effectiveness of the

  2. Comparison of DNA extraction methods for detection of citrus huanglongbing in Colombia

    Directory of Open Access Journals (Sweden)

    Jorge Evelio Ángel

    2014-04-01

    Full Text Available Four DNA citrus plant tissue extraction protocols and three methods of DNA extraction from vector psyllid Diaphorina citri Kuwayama (Hemiptera: Psyllidae were compared as part of the validation process and standardization for detection of huanglongbing (HLB. The comparison was done using several criterias such as integrity, purity and concentration. The best quality parameters presented in terms of extraction of DNA from plant midribs tissue of citrus, were cited by Murray and Thompson (1980 and Rodríguez et al. (2010, while for the DNA extraction from psyllid vectors of HLB, the best extraction method was suggested by Manjunath et al.(2008.

  3. Effect of dietary plant extract on meat quality and sensory parameters of meat from Equidae.

    Science.gov (United States)

    Rossi, Raffaella; Ratti, Sabrina; Pastorelli, Grazia; Maghin, Federica; Martemucci, Giovanni; Casamassima, Donato; D'Alessandro, Angela Gabriella; Corino, Carlo

    2017-11-01

    Plant extracts as Lippia spp. have been proven antioxidant properties. Recent studies have been shown that dietary supplementation with plant extracts is able to enhance meat quality parameters. Studies regarding meat quality in Equidae are limited. The effect of dietary plant extract (PE), containing verbascoside, on meat quality, oxidative stability and sensory parameters of Longissimus Lumborum (LL) muscle in Equidae was studied. Dietary treatment did not affect (P > 0.05) pH, colour indices and chemical parameters of muscle in both donkey and horse. Dietary PE improved (P meat and to affect the sensory attributes of Equidae meat. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  4. Effects of extraction parameters on physicochemical and functional characteristics of chitosan from Penaeus monodon shell

    Directory of Open Access Journals (Sweden)

    Jubril Olayinka Akolade

    2016-11-01

    Full Text Available Objective: To investigate the effect of extraction parameters with particular interest during the microwave deacetylation process on the characteristics of chitosan produced from Penaeus monodon (P. monodon sourced within the coastal region of Lagos, Nigeria for applications of controlled release systems for pharmaceutical industries. Methods: Chitosan was extracted from shrimp (P. monodon shell and evaluated as a controlled release system for curcumin. Effects of relevant processing parameters on physicochemical and functional characteristics of the extracted chitosan were assessed. The crude chitosan was purified and used to prepare controlled release formulations for curcumin via ionic gelation with tripolyphosphate. Results: Data from the study showed that increasing time and temperature during deproteinization significantly improved the removal of protein bound to the shell matrix. Also, the ratio of the weight of the deproteinized sample to the volume of HCl used for demineralization influenced the process. During microwave-assisted production of chitosan from chitin, increase in the concentration of the deacetylating medium significantly increased solubility, viscosity and degree of deacetylation, whereas increasing temperature and time during deacetylation of chitin degraded the biopolymer to give low molecular weight chitosan. Optimized extraction and purification process yielded absolutely soluble medium to low molecular weight chitosan. The encapsulation efficiency, loading capacity, percentage yield, release efficiencies in simulated gastric and intestinal fluids of curcumin loaded in the formulations of chitosan from P. monodon were compared favorably to encapsulation and release characteristics of the encapsulated curcumin in commercially available chitosan used as the reference. Conclusions: Valorization of shrimp waste into pharmaceutically graded medium molecular weight chitosan was achieved. The chitosan obtained can be used as

  5. Extraction Methods for the Isolation of Isoflavonoids from Plant Material

    Directory of Open Access Journals (Sweden)

    Blicharski Tomasz

    2017-03-01

    Full Text Available The purpose of this review is to describe and compare selected traditional and modern extraction methods employed in the isolation of isoflavonoids from plants. Conventional methods such as maceration, percolation, or Soxhlet extraction are still frequently used in phytochemical analysis. Despite their flexibility, traditional extraction techniques have significant drawbacks, including the need for a significant investment of time, energy, and starting material, and a requirement for large amounts of potentially toxic solvents. Moreover, these techniques are difficult to automate, produce considerable amount of waste and pose a risk of degradation of thermolabile compounds. Modern extraction methods, such as: ultrasound-assisted extraction, microwave-assisted extraction, accelerated solvent extraction, supercritical fluid extraction, and negative pressure cavitation extraction, can be regarded as remedies for the aforementioned problems. This manuscript discusses the use of the most relevant extraction techniques in the process of isolation of isoflavonoids, secondary metabolites that have been found to have a plethora of biological and pharmacological activities.

  6. Nowcasting Surface Meteorological Parameters Using Successive Correction Method

    National Research Council Canada - National Science Library

    Henmi, Teizi

    2002-01-01

    The successive correction method was examined and evaluated statistically as a nowcasting method for surface meteorological parameters including temperature, dew point temperature, and horizontal wind vector components...

  7. Vanadium extraction from slimes by the lime-bicarbonate method

    International Nuclear Information System (INIS)

    Lishchenko, T.V.; Vdovina, L.V.; Slobodchikova, R.I.

    1978-01-01

    Some main parameters of the lime-bicarbonate method of extracting vanadium from residues obtained in washing waters of mazut boilers on thermal stations have been determined. To study the process of vanadium extraction during caking of the residues with lime and subsequent leaching of water-soluble vanadium, a ''Minsk-22'' computer has been used for computation. Analysis of the equation derived has shown that a change in temperature of vanadium leaching, density of pulp, and a kind of heating of the charge affect the process only slightly. It has also been shown that the calcination temperature is expedient to be kept above 850 deg C and consumption temperature is expedient to be kept above 85O deg C and consumption of lime must not exceed 20% of the residues weight. Bicarbonate consumption exerts a decisive influence on completeness of vanadium extraction and must be increased up to >35%; duration of leaching should be raised up to 30-45 minutes. With increasing calcination temperature the duration of leaching decreases. When temperature and duration of calcination increase, the formation of water-soluble vanadium intensifies. With the aid of optimization program seven variants have been chosen, which ensure vanadium extraction into solution by 95-100%

  8. A Robust Gradient Based Method for Building Extraction from LiDAR and Photogrammetric Imagery

    Directory of Open Access Journals (Sweden)

    Fasahat Ullah Siddiqui

    2016-07-01

    Full Text Available Existing automatic building extraction methods are not effective in extracting buildings which are small in size and have transparent roofs. The application of large area threshold prohibits detection of small buildings and the use of ground points in generating the building mask prevents detection of transparent buildings. In addition, the existing methods use numerous parameters to extract buildings in complex environments, e.g., hilly area and high vegetation. However, the empirical tuning of large number of parameters reduces the robustness of building extraction methods. This paper proposes a novel Gradient-based Building Extraction (GBE method to address these limitations. The proposed method transforms the Light Detection And Ranging (LiDAR height information into intensity image without interpolation of point heights and then analyses the gradient information in the image. Generally, building roof planes have a constant height change along the slope of a roof plane whereas trees have a random height change. With such an analysis, buildings of a greater range of sizes with a transparent or opaque roof can be extracted. In addition, a local colour matching approach is introduced as a post-processing stage to eliminate trees. This stage of our proposed method does not require any manual setting and all parameters are set automatically from the data. The other post processing stages including variance, point density and shadow elimination are also applied to verify the extracted buildings, where comparatively fewer empirically set parameters are used. The performance of the proposed GBE method is evaluated on two benchmark data sets by using the object and pixel based metrics (completeness, correctness and quality. Our experimental results show the effectiveness of the proposed method in eliminating trees, extracting buildings of all sizes, and extracting buildings with and without transparent roof. When compared with current state

  9. Optimization of TRPO process parameters for americium extraction from high level waste

    International Nuclear Information System (INIS)

    Chen Jing; Wang Jianchen; Song Chongli

    2001-01-01

    The numerical calculations for Am multistage fractional extraction by trialkyl phosphine oxide (TRPO) were verified by a hot test. 1750L/t-U high level waste (HLW) was used as the feed to the TRPO process. The analysis used the simple objective function to minimize the total waste content in the TRPO process streams. Some process parameters were optimized after other parameters were selected. The optimal process parameters for Am extraction by TRPO are: 10 stages for extraction and 2 stages for scrubbing; a flow rate ratio of 0.931 for extraction and 4.42 for scrubbing; nitric acid concentration of 1.35 mol/L for the feed and 0.5 mol/L for the scrubbing solution. Finally, the nitric acid and Am concentration profiles in the optimal TRPO extraction process are given

  10. Effect of interpolation on parameters extracted from seating interface pressure arrays

    OpenAIRE

    Michael Wininger, PhD; Barbara Crane, PhD, PT

    2015-01-01

    Interpolation is a common data processing step in the study of interface pressure data collected at the wheelchair seating interface. However, there has been no focused study on the effect of interpolation on features extracted from these pressure maps, nor on whether these parameters are sensitive to the manner in which the interpolation is implemented. Here, two different interpolation paradigms, bilinear versus bicubic spline, are tested for their influence on parameters extracted from pre...

  11. Effect of Supercritical Carbon Dioxide Extraction Parameters on the Biological Activities and Metabolites Present in Extracts from Arthrospira platensis.

    Science.gov (United States)

    Esquivel-Hernández, Diego A; Rodríguez-Rodríguez, José; Cuéllar-Bermúdez, Sara P; García-Pérez, J Saúl; Mancera-Andrade, Elena I; Núñez-Echevarría, Jade E; Ontiveros-Valencia, Aura; Rostro-Alanis, Magdalena; García-García, Rebeca M; Torres, J Antonio; Chen, Wei Ning; Parra-Saldívar, Roberto

    2017-06-12

    Arthrospira platensis was used to obtain functional extracts through supercritical carbon dioxide extraction (SFE-CO₂). Pressure (P), temperature (T), co-solvent (CX), static extraction (SX), dispersant (Di) and dynamic extraction (DX) were evaluated as process parameters through a Plackett-Burman design. The maximum extract yield obtained was 7.48 ± 0.15% w/w. The maximum contents of bioactive metabolites in extracts were 0.69 ± 0.09 µg/g of riboflavin, 5.49 ± 0.10 µg/g of α-tocopherol, 524.46 ± 0.10 µg/g of β-carotene, 1.44 ± 0.10 µg/g of lutein and 32.11 ± 0.12 mg/g of fatty acids with 39.38% of palmitic acid, 20.63% of linoleic acid and 30.27% of γ-linolenic acid. A. platensis extracts had an antioxidant activity of 76.47 ± 0.71 µg GAE/g by Folin-Ciocalteu assay, 0.52 ± 0.02, 0.40 ± 0.01 and 1.47 ± 0.02 µmol TE/g by DPPH, FRAP and TEAC assays, respectively. These extracts showed antimicrobial activity against Staphylococcus aureus ATCC 25923, Pseudomonas aeruginosa ATCC 27853, Escherichia coli ATCC 25922 and Candida albicans ATCC 10231. Overall, co-solvent was the most significant factor for all measured effects ( p extraction parameters P: 450 bar, CX: 11 g/min, SX: 15 min, DX: 25 min, T: 60 °C and Di: 35 g.

  12. EM simulation assisted parameter extraction for the modeling of transferred-substrate InP HBTs

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Weimann, Nils; Doerner, Ralf

    2017-01-01

    In this paper an electromagnetic (EM) simulation assisted parameters extraction procedure is demonstrated for accurate modeling of down-scaled transferred-substrate InP HBTs. The external parasitic network associated with via transitions and device electrodes is carefully extracted from calibrate...

  13. Critical parameters in cost-effective alkaline extraction for high protein yield from leaves

    NARCIS (Netherlands)

    Zhang, C.; Sanders, J.P.M.; Bruins, M.E.

    2014-01-01

    Leaves are potential resources for feed or food, but their applications are limited due to a high proportion of insoluble protein and inefficient processing. To overcome these problems, parameters of alkaline extraction were evaluated using green tea residue (GTR). Protein extraction could be

  14. Biodiesel Production from Microalgae by Extraction – Transesterification Method

    Directory of Open Access Journals (Sweden)

    Nguyen Thi Phuong Thao

    2013-11-01

    Full Text Available The environmental impact of using petroleum fuels has led to a quest to find a suitable alternative fuel source. In this study, microalgae were explored as a highly potential feedstock to produce biodiesel fuel. Firstly, algal oil is extracted from algal biomass by using organic solvents (n–hexan.  Lipid is contained in microalgae up to 60% of their weight. Then, Biodiesel is created through a chemical reaction known as transesterification between algal oil and alcohol (methanol with strong acid (such as H2SO4 as the catalyst. The extraction – transesterification method resulted in a high biodiesel yield (10 % of algal biomass and high FAMEs content (5.2 % of algal biomass. Biodiesel production from microalgae was studied through experimental investigation of transesterification conditions such as reaction time, methanol to oil ration and catalyst dosage which are deemed to have main impact on reaction conversion efficiency. All the parameters which were characterized for purified biodiesel such as free glycerin, total glycerin, flash point, sulfur content were analyzed according to ASTM standardDoi: http://dx.doi.org/10.12777/wastech.1.1.6-9Citation:  Thao, N.T.P., Tin, N.T., and Thanh, B.X. 2013. Biodiesel Production from Microalgae by Extraction – Transesterification Method. Waste Technology 1(1:6-9. Doi: http://dx.doi.org/10.12777/wastech.1.1.6-9

  15. Evaluating the impact of extraction and cleanup parameters on the yield of total petroleum hydrocarbons in soil

    Energy Technology Data Exchange (ETDEWEB)

    Saari, Eija; Peraemaeki, Paavo; Jalonen, Jorma [University of Oulu, Department of Chemistry (Finland)

    2008-11-15

    Interlaboratory comparisons for the analysis of mineral oil in polluted soil using the GC-FID method indicate that extraction and cleanup conditions have significant effects on the analytical results. In this investigation a ruggedness test was performed on the extraction and cleanup method for the determination of total petroleum hydrocarbons in soil. A two-level Plackett-Burman design was utilized to study the effect of 11 different method parameters on the extraction recovery of total petroleum hydrocarbons (TPH) in soil. Both qualitative and quantitative factors were investigated. The results indicate that total petroleum hydrocarbons can be relatively reliably monitored through strict implementation of the ISO and CEN draft standards. However, variation in certain method parameters readily affects the validity of the results. The most critical factors affecting TPH recovery were the solvent and co-solvent used for extraction, the extraction time, adsorbent and its weight and sample TPH concentration. Because adaptation of the draft standards especially with respect to these factors easily leads to TPH recoveries higher than 200% or lower than 70%, the validity of the adapted method should always be verified. A proper estimate of the expanded uncertainty should also be appended to TPH results, because only then can the reliability of the results be guaranteed and further justification is gained to support the end-use of the data. This also supports the credibility of the analytical services and prevents the data end-users from drawing misleading conclusions concerning the environmental risks and potential remediation requirements. (orig.)

  16. Comparative study of methods for extraction and purification of ...

    African Journals Online (AJOL)

    USER

    2010-08-02

    Aug 2, 2010 ... and or enzymatic lysis for direct or indirect extraction of. DNA followed by ... strength wastewater sludge in order to determine the best. DNA extraction protocol ... Ammonium acetate purification method was used to remove the.

  17. Cat's claw oxindole alkaloid isomerization induced by common extraction methods

    Directory of Open Access Journals (Sweden)

    Samuel Kaiser

    2013-01-01

    Full Text Available Cat's claw oxindole alkaloids are prone to isomerization in aqueous solution. However, studies on their behavior in extraction processes are scarce. This paper addressed the issue by considering five commonly used extraction processes. Unlike dynamic maceration (DM and ultrasound-assisted extraction, substantial isomerization was induced by static maceration, turbo-extraction and reflux extraction. After heating under reflux in DM, the kinetic order of isomerization was established and equations were fitted successfully using a four-parameter Weibull model (R² > 0.999. Different isomerization rates and equilibrium constants were verified, revealing a possible matrix effect on alkaloid isomerization.

  18. Automated extraction and validation of children's gait parameters with the Kinect.

    Science.gov (United States)

    Motiian, Saeid; Pergami, Paola; Guffey, Keegan; Mancinelli, Corrie A; Doretto, Gianfranco

    2015-12-02

    Gait analysis for therapy regimen prescription and monitoring requires patients to physically access clinics with specialized equipment. The timely availability of such infrastructure at the right frequency is especially important for small children. Besides being very costly, this is a challenge for many children living in rural areas. This is why this work develops a low-cost, portable, and automated approach for in-home gait analysis, based on the Microsoft Kinect. A robust and efficient method for extracting gait parameters is introduced, which copes with the high variability of noisy Kinect skeleton tracking data experienced across the population of young children. This is achieved by temporally segmenting the data with an approach based on coupling a probabilistic matching of stride template models, learned offline, with the estimation of their global and local temporal scaling. A preliminary study conducted on healthy children between 2 and 4 years of age is performed to analyze the accuracy, precision, repeatability, and concurrent validity of the proposed method against the GAITRite when measuring several spatial and temporal children's gait parameters. The method has excellent accuracy and good precision, with segmenting temporal sequences of body joint locations into stride and step cycles. Also, the spatial and temporal gait parameters, estimated automatically, exhibit good concurrent validity with those provided by the GAITRite, as well as very good repeatability. In particular, on a range of nine gait parameters, the relative and absolute agreements were found to be good and excellent, and the overall agreements were found to be good and moderate. This work enables and validates the automated use of the Kinect for children's gait analysis in healthy subjects. In particular, the approach makes a step forward towards developing a low-cost, portable, parent-operated in-home tool for clinicians assisting young children.

  19. System and method for free-boundary surface extraction

    KAUST Repository

    Algarni, Marei

    2017-10-26

    A method of extracting surfaces in three-dimensional data includes receiving as inputs three-dimensional data and a seed point p located on a surface to be extracted. The method further includes propagating a front outwardly from the seed point p and extracting a plurality of ridge curves based on the propagated front. A surface boundary is detected based on a comparison of distances between adjacent ridge curves and the desired surface is extracted based on the detected surface boundary.

  20. A Comparative Study of Distribution System Parameter Estimation Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yannan; Williams, Tess L.; Gourisetti, Sri Nikhil Gup

    2016-07-17

    In this paper, we compare two parameter estimation methods for distribution systems: residual sensitivity analysis and state-vector augmentation with a Kalman filter. These two methods were originally proposed for transmission systems, and are still the most commonly used methods for parameter estimation. Distribution systems have much lower measurement redundancy than transmission systems. Therefore, estimating parameters is much more difficult. To increase the robustness of parameter estimation, the two methods are applied with combined measurement snapshots (measurement sets taken at different points in time), so that the redundancy for computing the parameter values is increased. The advantages and disadvantages of both methods are discussed. The results of this paper show that state-vector augmentation is a better approach for parameter estimation in distribution systems. Simulation studies are done on a modified version of IEEE 13-Node Test Feeder with varying levels of measurement noise and non-zero error in the other system model parameters.

  1. Characteristics of prickly lettuce seed oil in relation to methods of extraction.

    Science.gov (United States)

    Ramadan, A A

    1976-01-01

    Samples of seed oil of prickly lettuce (Lactuca Sacriola oleifera) which had been obtained by pressing or by extracting with acetone, ethyl ether, petroleum ether or carbon tetrachloride were analysed for the following parameters: viscosity, saponification number, iodine number, thiocyanogen value, unsaponifiable matter, free fatty acids, peroxide number and fatty acid composition. The different parameters varied in part considerably in relation to the method of production (pressing or solvent extraction) and to the solvent. It is tried to interprete these relationships.

  2. Effects of ginseng extract on various haematological parameters during aerobic exercise in the rat.

    Science.gov (United States)

    Ferrando, A; Vila, L; Voces, J A; Cabral, A C; Alvarez, A I; Prieto, J G

    1999-04-01

    The effects of the Ginseng extract on various biochemical and haematological parameters in male Wistar rats subjected to a treadmill exercise protocol were studied for 12 weeks. The results showed increases in the haematological parameters, these increases being greatest for the animals treated with the extract during the third month of the study. The exercise also led to increases in these parameters, while the combination of both exercise and extract produced smaller increases. This study shows a clear physiological response due to the ginseng extract administration that reproduces many of the effects obtained after long-term exercise. The combination of exercise and treatments seems to support the theory that there is no clear synergic effect when the advantages associated with the ingestion of ginseng are compared with the performance of exercise.

  3. Optimizing pressurized liquid extraction of microbial lipids using the response surface method.

    Science.gov (United States)

    Cescut, J; Severac, E; Molina-Jouve, C; Uribelarrea, J-L

    2011-01-21

    Response surface methodology (RSM) was used for the determination of optimum extraction parameters to reach maximum lipid extraction yield with yeast. Total lipids were extracted from oleaginous yeast (Rhodotorula glutinis) using pressurized liquid extraction (PLE). The effects of extraction parameters on lipid extraction yield were studied by employing a second-order central composite design. The optimal condition was obtained as three cycles of 15 min at 100°C with a ratio of 144 g of hydromatrix per 100 g of dry cell weight. Different analysis methods were used to compare the optimized PLE method with two conventional methods (Soxhlet and modification of Bligh and Dyer methods) under efficiency, selectivity and reproducibility criteria thanks to gravimetric analysis, GC with flame ionization detector, High Performance Liquid Chromatography linked to Evaporative Light Scattering Detector (HPLC-ELSD) and thin-layer chromatographic analysis. For each sample, the lipid extraction yield with optimized PLE was higher than those obtained with referenced methods (Soxhlet and Bligh and Dyer methods with, respectively, a recovery of 78% and 85% compared to PLE method). Moreover, the use of PLE led to major advantages such as an analysis time reduction by a factor of 10 and solvent quantity reduction by 70%, compared with traditional extraction methods. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Synergistic improvement of gas sensing performance by micro-gravimetrically extracted kinetic/thermodynamic parameters

    International Nuclear Information System (INIS)

    Guo, Shuanbao; Xu, Pengcheng; Yu, Haitao; Cheng, Zhenxing; Li, Xinxin

    2015-01-01

    Highlights: • Sensing material can be comprehensively optimized by using gravimetric cantilever. • Kinetic-thermodynamic model parameters are quantitatively extracted by experiment • Sensing-material performance is synergistically optimized by extracted parameters. - Abstract: A novel method is explored for comprehensive design/optimization of organophosphorus sensing material, which is loaded on mass-type microcantilever sensor. Conventionally, by directly observing the gas sensing response, it is difficult to build quantitative relationship with the intrinsic structure of the material. To break through this difficulty, resonant cantilever is employed as gravimetric tool to implement molecule adsorption experiment. Based on the sensing data, key kinetic/thermodynamic parameters of the material to the molecule, including adsorption heat −ΔH°, adsorption/desorption rate constants K a and K d , active-site number per unit mass N′ and surface coverage θ, can be quantitatively extracted according to physical–chemistry theories. With gaseous DMMP (simulant of organophosphorus agents) as sensing target, the optimization route for three sensing materials is successfully demonstrated. Firstly, a hyper-branched polymer is evaluated. Though suffering low sensitivity due to insufficient N′, the bis(4-hydroxyphenyl)-hexafluoropropane (BHPF) sensing-group exhibits satisfactory reproducibility due to appropriate −ΔH°. To achieve more sensing-sites, KIT-5 mesoporous-silica with higher surface-area is assessed, resulting in good sensitivity but too high −ΔH° that brings poor repeatability. After comprehensive consideration, the confirmed BHPF sensing-group is grafted on the KIT-5 carrier to form an optimized DMMP sensing nanomaterial. Experimental results indicate that, featuring appropriate kinetic/thermodynamic parameters of −ΔH°, K a , K d , N′ and θ, the BHPF-functionalized KIT-5 mesoporous silica exhibits synergistic improvement among

  5. SKOCh modified parameters and data processing method

    International Nuclear Information System (INIS)

    Abramov, V.V.; Baldin, B.Yu.; Vasil'chenko, V.G.

    1986-01-01

    Characteristics of a modified Cherenkov radiation ring spectrometer variant (SKOCH) are presented. Methods of experimental data processing are described. Different SKOCH optics variants are investigated. Multi-particle registering electronic equipment for data read-out from SKOCH providing for the improvement of multiparticle occurance registration conditions is applied in the course of measurements using proton beams. A system of SKOCH spectrometer data processing programms is developed and experimentally tested. Effective algorithm for calibrating Cherenkov radiation ring spectrometers with quite a large angular and radial aperture is developed. The on-line- and off-line-processing program complex provides for the complete control of SKOCH operation during statistics collection and for particle (π, K, P) identification within 5.5-30 GeV/c range

  6. Evaluation of urinary cortisol excretion by radioimmunoassay through two methods (extracted and non-extracted)

    International Nuclear Information System (INIS)

    Fonte Kohek, M.B. da; Mendonca, B.B. de; Nicolau, W.

    1993-01-01

    The objective of this paper is to compare the feasibility, sensitivity and specificity of both methods (extracted versus non-extracted) in the hypercortisolism diagnosis. It used Gamma Coat 125 cortisol Kit provided by Clinical Assays, Incstar, USA, for both methods extracting it with methylene chloride in order to measure the extracted cortisol. It was performed 32 assays from which it was obtained from 0.1 to 0.47 u g/d l of sensitivity. The intra-run precision was varied from 8.29 +- 3.38% and 8.19 +-4.72% for high and low levels, respectively for non-extracted cortisol, and 9.72 +- 1.94% and 9.54 +- 44% for high and low levels, respectively, for extracted cortisol. The inter-run precision was 15.98% and 16.15% for high level of non-extracted cortisol, respectively. For the low level it obtained 17.25% and 18.59% for non-extracted and extracted cortisol respectively. It was evaluated 24-hour urine basal samples from 43 normal subjects, and 53 obese (body mass index > 30) and 53 Cushing's syndrome patients. The sensitivity of the methods were similar (100% and 98.1% for non-extracted and extracted methods, respectively) and the specificity was the same for both methods (100%). It was noticed a positive correlation between the two methods in all the groups studied (p s syndrome. (author)

  7. Natural colorants: Pigment stability and extraction yield enhancement via utilization of appropriate pretreatment and extraction methods.

    Science.gov (United States)

    Ngamwonglumlert, Luxsika; Devahastin, Sakamon; Chiewchan, Naphaporn

    2017-10-13

    Natural colorants from plant-based materials have gained increasing popularity due to health consciousness of consumers. Among the many steps involved in the production of natural colorants, pigment extraction is one of the most important. Soxhlet extraction, maceration, and hydrodistillation are conventional methods that have been widely used in industry and laboratory for such a purpose. Recently, various non-conventional methods, such as supercritical fluid extraction, pressurized liquid extraction, microwave-assisted extraction, ultrasound-assisted extraction, pulsed-electric field extraction, and enzyme-assisted extraction have emerged as alternatives to conventional methods due to the advantages of the former in terms of smaller solvent consumption, shorter extraction time, and more environment-friendliness. Prior to the extraction step, pretreatment of plant materials to enhance the stability of natural pigments is another important step that must be carefully taken care of. In this paper, a comprehensive review of appropriate pretreatment and extraction methods for chlorophylls, carotenoids, betalains, and anthocyanins, which are major classes of plant pigments, is provided by using pigment stability and extraction yield as assessment criteria.

  8. The method for simultaneous extraction and back extraction in liquid three-phase system and equipment for simultaneous extraction and back extraction in liquid three-phase system

    International Nuclear Information System (INIS)

    Palyska, W.; Chmielewski, A.G.

    1992-01-01

    The method for simultaneous extraction and back extraction in liquid three-phase system has been worked out. The equipment designed for that process has been also subject of the patent. The interesting component is extracted first to intermediate phase consists of magnetic solvent keeping two extracting phases separately. The intermediate magnetic liquid has been kept in its position using a stable magnet maintained on the surface of the extraction vessel. Then the component pass from intermediate phase to the third phase as a result of back extraction. Mixing in the extraction and back extraction zones is organized by means of rotating shaft going along the whole apparatus. The extraction and back extraction processes occur simultaneously as a result of continuous flow of solvent in their zones. The single extraction back extraction facilities can be joined in larger batteries. 3 figs

  9. Social network extraction based on Web: 1. Related superficial methods

    Science.gov (United States)

    Khairuddin Matyuso Nasution, Mahyuddin

    2018-01-01

    Often the nature of something affects methods to resolve the related issues about it. Likewise, methods to extract social networks from the Web, but involve the structured data types differently. This paper reveals several methods of social network extraction from the same sources that is Web: the basic superficial method, the underlying superficial method, the description superficial method, and the related superficial methods. In complexity we derive the inequalities between methods and so are their computations. In this case, we find that different results from the same tools make the difference from the more complex to the simpler: Extraction of social network by involving co-occurrence is more complex than using occurrences.

  10. Optimization-based Method for Automated Road Network Extraction

    International Nuclear Information System (INIS)

    Xiong, D

    2001-01-01

    Automated road information extraction has significant applicability in transportation. It provides a means for creating, maintaining, and updating transportation network databases that are needed for purposes ranging from traffic management to automated vehicle navigation and guidance. This paper is to review literature on the subject of road extraction and to describe a study of an optimization-based method for automated road network extraction

  11. Steroid hormones in environmental matrices: extraction method comparison.

    Science.gov (United States)

    Andaluri, Gangadhar; Suri, Rominder P S; Graham, Kendon

    2017-11-09

    The U.S. Environmental Protection Agency (EPA) has developed methods for the analysis of steroid hormones in water, soil, sediment, and municipal biosolids by HRGC/HRMS (EPA Method 1698). Following the guidelines provided in US-EPA Method 1698, the extraction methods were validated with reagent water and applied to municipal wastewater, surface water, and municipal biosolids using GC/MS/MS for the analysis of nine most commonly detected steroid hormones. This is the first reported comparison of the separatory funnel extraction (SFE), continuous liquid-liquid extraction (CLLE), and Soxhlet extraction methods developed by the U.S. EPA. Furthermore, a solid phase extraction (SPE) method was also developed in-house for the extraction of steroid hormones from aquatic environmental samples. This study provides valuable information regarding the robustness of the different extraction methods. Statistical analysis of the data showed that SPE-based methods provided better recovery efficiencies and lower variability of the steroid hormones followed by SFE. The analytical methods developed in-house for extraction of biosolids showed a wide recovery range; however, the variability was low (≤ 7% RSD). Soxhlet extraction and CLLE are lengthy procedures and have been shown to provide highly variably recovery efficiencies. The results of this study are guidance for better sample preparation strategies in analytical methods for steroid hormone analysis, and SPE adds to the choice in environmental sample analysis.

  12. Evaluation of urinary excretion of cortisol by radioimmunoassay through two methods (extracted and non-extracted)

    International Nuclear Information System (INIS)

    Fonte Kohek, M.B. da.

    1992-01-01

    The radioimmunoassay of urinary cortisol extracted by organic solvent (free cortisol) has been used for along time in the hypercortisolism diagnosis. With the development of more specific antisera it became possible to measure urinary cortisol without extracting it. The objective of this paper is to compare the feasibility, sensitivity and specificity of both methods (extracted versus non-extracted) in the hypercortisolism diagnosis. It was used Gamma Coat 125 I - cortisol kit provided by Clinical Assay, Incstar, US, for both methods extracting it with methylene chloride in order to measure the extracted cortisol. The sensitivity of the methods were similar (100% and 98,1%, for non-extracted and extracted methods, respectively). A positive correlation between the two methods was noticed in all groups studied (p < 0.05). It was concluded that both methods are efficient for the investigation of hypercortisolism. However, it's suggested that non-extracted urinary cortisol measurement should be the method of choice since it's an easy-to-perform and affordable method to diagnose Cushing's syndrome. (author)

  13. Simple method for quick estimation of aquifer hydrogeological parameters

    Science.gov (United States)

    Ma, C.; Li, Y. Y.

    2017-08-01

    Development of simple and accurate methods to determine the aquifer hydrogeological parameters was of importance for groundwater resources assessment and management. Aiming at the present issue of estimating aquifer parameters based on some data of the unsteady pumping test, a fitting function of Theis well function was proposed using fitting optimization method and then a unitary linear regression equation was established. The aquifer parameters could be obtained by solving coefficients of the regression equation. The application of the proposed method was illustrated, using two published data sets. By the error statistics and analysis on the pumping drawdown, it showed that the method proposed in this paper yielded quick and accurate estimates of the aquifer parameters. The proposed method could reliably identify the aquifer parameters from long distance observed drawdowns and early drawdowns. It was hoped that the proposed method in this paper would be helpful for practicing hydrogeologists and hydrologists.

  14. Comparative exergy analyses of Jatropha curcas oil extraction methods: Solvent and mechanical extraction processes

    International Nuclear Information System (INIS)

    Ofori-Boateng, Cynthia; Keat Teong, Lee; JitKang, Lim

    2012-01-01

    Highlights: ► Exergy analysis detects locations of resource degradation within a process. ► Solvent extraction is six times exergetically destructive than mechanical extraction. ► Mechanical extraction of jatropha oil is 95.93% exergetically efficient. ► Solvent extraction of jatropha oil is 79.35% exergetically efficient. ► Exergy analysis of oil extraction processes allow room for improvements. - Abstract: Vegetable oil extraction processes are found to be energy intensive. Thermodynamically, any energy intensive process is considered to degrade the most useful part of energy that is available to produce work. This study uses literature values to compare the efficiencies and degradation of the useful energy within Jatropha curcas oil during oil extraction taking into account solvent and mechanical extraction methods. According to this study, J. curcas seeds on processing into J. curcas oil is upgraded with mechanical extraction but degraded with solvent extraction processes. For mechanical extraction, the total internal exergy destroyed is 3006 MJ which is about six times less than that for solvent extraction (18,072 MJ) for 1 ton J. curcas oil produced. The pretreatment processes of the J. curcas seeds recorded a total internal exergy destructions of 5768 MJ accounting for 24% of the total internal exergy destroyed for solvent extraction processes and 66% for mechanical extraction. The exergetic efficiencies recorded are 79.35% and 95.93% for solvent and mechanical extraction processes of J. curcas oil respectively. Hence, mechanical oil extraction processes are exergetically efficient than solvent extraction processes. Possible improvement methods are also elaborated in this study.

  15. A System for Extracting Study Design Parameters from Nutritional Genomics Abstracts

    Directory of Open Access Journals (Sweden)

    Kelly Cassidy

    2013-06-01

    Full Text Available The extraction of study design parameters from biomedical journal articles is an important problem in natural language processing (NLP. Such parameters define the characteristics of a study, such as the duration, the number of subjects, and their profile. Here we present a system for extracting study design parameters from sentences in article abstracts. This system will be used as a component of a larger system for creating nutrigenomics networks from articles in the nutritional genomics domain. The algorithms presented consist of manually designed rules expressed either as regular expressions or in terms of sentence parse structure. A number of filters and NLP tools are also utilized within a pipelined algorithmic framework. Using this novel approach, our system performs extraction at a finer level of granularity than comparable systems, while generating results that surpass the current state of the art.

  16. Effects of Watercress (Nasturtium nasturtium extract on selected immunological parameters of rainbow trout (Oncorhynchus mykiss

    Directory of Open Access Journals (Sweden)

    K. Ahmadi

    2012-05-01

    Full Text Available Watercress (Nasturtium nasturtium is a medical plant containing diverse chemically-active substances with biological properties. The present study was conducted to investigate the immunomodulatory effects of watercress extract on immunological and hematological parameters of rainbow trout (Oncorhynchus mykiss. Fish were fed for 21 days with diet supplemented with 0.1% and 1% of watercress extract per 1 kg food and with a normal diet as control. Hematological parameters such as red blood cells (RBC and white blood cells (WBC, hematocrit (Hct, hemoglobin (Hb, RBC index like mean corpuscular volume (MCV, mean corpuscular hemoglobin (MCH and mean corpuscular hemoglobin concentration (MCHC as well as immunological parameters such as peroxidase, lysozyme and complement activities, total protein, albumin and globulin levels were measured after 21 days of watercress extract treatment. The results indicated that oral administration of 1 % watercress extract in fish may enhance some hematological and immunological parameters including Hb and MCHC, lysozyme and complement activities, total protein and globulin levels, compared to the controls after 21 days of experimental period. In conclusion, on the basis of these results, oral administration of watercress extract may be useful to improve fish’s immune system.

  17. Methods for microbial DNA extraction from soil for PCR amplification

    Directory of Open Access Journals (Sweden)

    Yeates C

    1998-01-01

    Full Text Available Amplification of DNA from soil is often inhibited by co-purified contaminants. A rapid, inexpensive, large-scale DNA extraction method involving minimal purification has been developed that is applicable to various soil types (1. DNA is also suitable for PCR amplification using various DNA targets. DNA was extracted from 100g of soil using direct lysis with glass beads and SDS followed by potassium acetate precipitation, polyethylene glycol precipitation, phenol extraction and isopropanol precipitation. This method was compared to other DNA extraction methods with regard to DNA purity and size.

  18. Optimization of extraction parameters on the antioxidant properties of banana waste.

    Science.gov (United States)

    Toh, Pui Yee; Leong, Fei Shan; Chang, Sui Kiat; Khoo, Hock Eng; Yim, Hip Seng

    2016-01-01

    Banana is grown worldwide and consumed as ripe fruit or used for culinary purposes. Peels form about 18-33% of the whole fruit and are discarded as a waste product. With a view to exploiting banana peel as a source of valuable compounds, this study was undertaken to evaluate the effect of different extraction parameters on the antioxidant activities of the industrial by-product of banana waste (peel). Influence of different extraction parameters such as types of solvent, percentages of solvent, and extraction times on total phenolic content (TPC) and antioxidant activity of mature and green peels of Pisang Abu (PA), Pisang Berangan (PB), and Pisang Mas (PM) were investigated. The best extraction parameters were initially selected based on different percentages of ethanol (0-100% v/v), extraction time (1-5 hr), and extraction temperature (25-60°C) for extraction of antioxidants in the banana peels. Total phenolic content (TPC) was evaluated using Folin-Ciocalteu reagent assay while antioxidant activities (AA) of banana peel were accessed by DPPH, ABTS, and β-carotene bleaching (BCB) assays at optimum extraction conditions. Based on different extraction solvents and percentages of solvents used, 70% and 90% of acetone had yielded the highest TPC for the mature and green PA peels, respectively; 90% of ethanol and methanol has yielded the highest TPC for the mature and green PB peels, respectively; while 90% ethanol for the mature and green PM peels. Similar extraction conditions were found for the antioxidant activities for the banana peel assessed using DPPH assay except for green PB peel, which 70% methanol had contributed to the highest AA. Highest TPC and AA were obtained by applying 4, 1, and 2 hrs extraction for the peels of PA, PB and PM, respectively. The best extraction conditions were also used for determination of AAs using ABTS and β-carotene bleaching assays. Therefore, the best extraction conditions used have given the highest TPC and AAs. By

  19. Effect of mucin extraction method on some properties of ...

    African Journals Online (AJOL)

    Effect of mucin extraction method on some properties of metronidazole mucoadhesive loaded patches. MI Arhewoh, SO Eraga, PF Builders, MA Ibobiri. Abstract. To evaluate the effects of mucin extraction method and plasticizer concentration on the bioadhesive strength and metronidazole release profile from mucin-based ...

  20. Method of purifying phosphoric acid after solvent extraction

    International Nuclear Information System (INIS)

    Kouloheris, A.P.; Lefever, J.A.

    1979-01-01

    A method of purifying phosphoric acid after solvent extraction is described. The phosphoric acid is contacted with a sorbent which sorbs or takes up the residual amount of organic carrier and the phosphoric acid separated from the organic carrier-laden sorbent. The method is especially suitable for removing residual organic carrier from phosphoric acid after solvent extraction uranium recovery. (author)

  1. Method of extracting tritium from heavy water

    International Nuclear Information System (INIS)

    Tsuchiya, Hiroyuki; Kikuchi, Makoto; Asakura, Yamato; Yusa, Hideo.

    1979-01-01

    Purpose: To extract tritium in heavy water by combining isotope exchange reaction with liquefaction distillation to increase the concentration of recovered tritium, thereby reducing the quantity of radioactive wastes recovered. Constitution: Heavy water containing tritium from a reactor is introduced into a tritium separator through a conduit pipe. On the other hand, a D 2 gas is introduced through the conduit pipe in the lower part of a tritium separator to transfer tritium into D 2 gas by isotope exchange. The D 2 gas containing DT is introduced into a liquefaction distillation tower together with an outlet gas of a converter supplied through a pipeline. The converter is filled with net-like metals of platinum group such as Pt, Ni, Pd and the like, and the D 2 gas affluent in DT, extracted from the distillation tower is converted into D 2 and T 2 . The gas which has been introduced into the liquefaction distillation tower is liquefied. The D 2 gas of low boiling point components reaches the tower top, and the T 2 gas of high boiling point components is concentrated at the tower bottom, and is rendered into tritium water in a recoupler and stored in a water storage apparatus. (Yoshino, Y.)

  2. New de-embedding structures for extracting the electrical parameters of a through-silicon-via pair

    International Nuclear Information System (INIS)

    Zhou Jing; Wan Lixi; Li Jun; Wang Huijuan; Dai Fengwei; Cao Liqiang; Yu Daquan; Guidotti, Daniel

    2013-01-01

    Two innovative de-embedding methods are proposed for extracting an electrical model for a through-silicon-via (TSV) pair consisting of a ground-signal (GS) structure. In addition, based on microwave network theory, a new solution scheme is developed for dealing with multiple solutions of the transfer matrix during the process of de-embedding. A unique solution is determined based on the amplitude and the phase characteristic of S parameters. In the first de-embedding method, a typical “π“ type model of the TSV pair is developed, which illustrates the need to allow for frequency dependence in the equivalent TSV pair Spice model. This de-embedding method is shown to be effective for extracting the electrical properties of the TSVs. The feasibility of a second de-embedding method is also investigated. (semiconductor integrated circuits)

  3. Effects of Different Extraction Methods and Conditions on the Phenolic Composition of Mate Tea Extracts

    Directory of Open Access Journals (Sweden)

    Jelena Vladic

    2012-03-01

    Full Text Available A simple and rapid HPLC method for determination of chlorogenic acid (5-O-caffeoylquinic acid in mate tea extracts was developed and validated. The chromatography used isocratic elution with a mobile phase of aqueous 1.5% acetic acid-methanol (85:15, v/v. The flow rate was 0.8 mL/min and detection by UV at 325 nm. The method showed good selectivity, accuracy, repeatability and robustness, with detection limit of 0.26 mg/L and recovery of 97.76%. The developed method was applied for the determination of chlorogenic acid in mate tea extracts obtained by ethanol extraction and liquid carbon dioxide extraction with ethanol as co-solvent. Different ethanol concentrations were used (40, 50 and 60%, v/v and liquid CO2 extraction was performed at different pressures (50 and 100 bar and constant temperature (27 ± 1 °C. Significant influence of extraction methods, conditions and solvent polarity on chlorogenic acid content, antioxidant activity and total phenolic and flavonoid content of mate tea extracts was established. The most efficient extraction solvent was liquid CO2 with aqueous ethanol (40% as co-solvent using an extraction pressure of 100 bar.

  4. Extraction and identification of cyclobutanones from irradiated cheese employing a rapid direct solvent extraction method.

    Science.gov (United States)

    Tewfik, Ihab

    2008-01-01

    2-Alkylcyclobutanones (cyclobutanones) are accepted as chemical markers for irradiated foods containing lipid. However, current extraction procedures (Soxhlet-florisil chromatography) for the isolation of these markers involve a long and tedious clean-up regime prior to gas chromatography-mass spectrophotometry identification. This paper outlines an alternative isolation and clean-up method for the extraction of cyclobutanones in irradiated Camembert cheese. The newly developed direct solvent extraction method enables the efficient screening of large numbers of food samples and is not as resource intensive as the BS EN 1785:1997 method. Direct solvent extraction appears to be a simple, robust method and has the added advantage of a considerably shorter extraction time for the analysis of foods containing lipid.

  5. Impact of different extraction methods on the quality of Dipteryx alata extracts

    Directory of Open Access Journals (Sweden)

    Frederico S. Martins

    2013-05-01

    Full Text Available This study aimed to impact of different extraction methods on the quality of Dipteryx alata Vogel, Fabaceae, extracts from fruits. The major compounds found were the lipids 38.9% (w/w and proteins 26.20% (w/w. The residual moisture was 7.20% (w/w, total fiber 14.50% (w/w, minerals 4.10% (w/w and carbohydrate 9.10 % (w/w. The species studied has great potential in producing oil, but the content and type of fatty acids obtained is dependent on the method of extraction. The Blingh & Dyer method was more selective for unsaturated fatty acids and Shoxlet method was more selective for saturated fatty acids. The tannin extraction by ultrasound (33.70 % w/w was 13.90% more efficient than extraction by decoction (29 % w/w.

  6. A Fault Alarm and Diagnosis Method Based on Sensitive Parameters and Support Vector Machine

    Science.gov (United States)

    Zhang, Jinjie; Yao, Ziyun; Lv, Zhiquan; Zhu, Qunxiong; Xu, Fengtian; Jiang, Zhinong

    2015-08-01

    Study on the extraction of fault feature and the diagnostic technique of reciprocating compressor is one of the hot research topics in the field of reciprocating machinery fault diagnosis at present. A large number of feature extraction and classification methods have been widely applied in the related research, but the practical fault alarm and the accuracy of diagnosis have not been effectively improved. Developing feature extraction and classification methods to meet the requirements of typical fault alarm and automatic diagnosis in practical engineering is urgent task. The typical mechanical faults of reciprocating compressor are presented in the paper, and the existing data of online monitoring system is used to extract fault feature parameters within 15 types in total; the inner sensitive connection between faults and the feature parameters has been made clear by using the distance evaluation technique, also sensitive characteristic parameters of different faults have been obtained. On this basis, a method based on fault feature parameters and support vector machine (SVM) is developed, which will be applied to practical fault diagnosis. A better ability of early fault warning has been proved by the experiment and the practical fault cases. Automatic classification by using the SVM to the data of fault alarm has obtained better diagnostic accuracy.

  7. Evaluation of Extraction and Degradation Methods to Obtain Chickpeasaponin B1 from Chickpea (Cicer arietinum L.).

    Science.gov (United States)

    Cheng, Kun; Gao, Hua; Wang, Rong-Rong; Liu, Yang; Hou, Yu-Xue; Liu, Xiao-Hong; Liu, Kun; Wang, Wei

    2017-02-21

    The objective of this research is to implement extraction and degradation methods for the obtainment of 3- O -[α-l-rhamnopyranosyl-(1→2)-β-d-galactopyranosyl] soyasapogenol B (chickpeasaponin B1) from chickpea. The effects of microwave-assisted extraction (MAE) processing parameters-such as ethanol concentration, solvent/solid ratio, extraction temperature, microwave irradiation power, and irradiation time-were evaluated. Using 1g of material with 8 mL of 70% aqueous ethanol and an extraction time of 10 min at 70 °C under irradiation power 400W provided optimal extraction conditions. Compared with the conventional extraction techniques, including heat reflux extraction (HRE), Soxhlet extraction (SE), and ultrasonic extraction (UE), MAE produced higher extraction efficiency under a lower extraction time. DDMP (2,3-dihydro-2,5-dihydroxy-6-methyl-4 H -pyran-4-one) saponin can be degraded to structurally stable saponin B by the loss of its DDMP group. The influence of pH and the concentration of potassium hydroxide on transformation efficiency of the target compound was investigated. A solution of 0.25 M potassium hydroxide in 75% aqueous ethanol was suitable for converting the corresponding DDMP saponins of chickpeasaponin B1. The implementation by the combining MAE technique and alkaline hydrolysis method for preparing chickpeasaponin B1 provides a convenient technology for future applications.

  8. Effect of subchronic administration of nutmeg (Myristica fragrans Houtt) ethanolic extract to hematological parameters in rat

    Science.gov (United States)

    Bachri, M. S.; Yuliani, S.; Sari, A. K.

    2017-11-01

    Nutmeg is dried kernel of broadly ovoid seed of Myristica fragrans Houtt. It has been mentioned in ethnomedical literature as aphrodisiac, stomachic, carminative, tonic, and nervous stimulant. In order to establish the safety of nutmeg, the effect of the repeated administration of nutmeg is needed. The study was aimed to determine the toxic effect of subchronic administration of nutmeg ethanolic extract to hematological parameters in rat. A total of 28 male adult Wistar rats divided into 4 groups. Group I as control was given by 0.5% CMC-suspension, group II, III, and IV were given by 50, 100, and 200 mg/kg bw, respectively, of nutmeg ethanolic extract. The treatments were administered daily for 31 days. On day 31 bloods were taken from orbital sinus. The hematological parameter consisted of the numbers of erythrocyte and leukocyte as well as hemoglobin and total protein levels were measured. The data were statistically analyzed by one way Anova followed by LSD test. All of observed hematological parameters in rats showed that there were no significant difference between the nutmeg ethanolic extract treated groups and control group. The result indicated that the subchronic administration of 50, 100, and 200 mg/kg bw of nutmeg ethanolic extract did not cause the change of hematological parameters in rat.

  9. Investigation of parameters affecting the online combination of supercritical fluid extraction with capillary gas chromatography

    NARCIS (Netherlands)

    Lou, X.W.; Janssen, J.G.M.; Cramers, C.A.M.G.

    1996-01-01

    Two different injectors, a split/splitless injector and a programmed temperature vaporizer (PTV) injector were investigated as the interface in on-line supercritical fluid extraction (SFE)-capillary gas chromatography (cGC). The parameters affecting the chromatographic peak shapes as well as the

  10. Process intensification for biodiesel production from Jatropha curcas L. seeds: Supercritical reactive extraction process parameters study

    International Nuclear Information System (INIS)

    Lim, Steven; Lee, Keat Teong

    2013-01-01

    Highlights: ► Investigation of supercritical reactive extraction process for biodiesel production. ► Focus is given on optimizing methyl esters yield for Jatropha curcas L. seeds. ► Influence of process parameters to the reaction are discussed thoroughly. ► Comparison between the novel reaction with conventional process are studied. ► High methyl esters yield can be obtained without pre-extraction and catalyst. -- Abstract: In a bid to increase the cost competitiveness of biodiesel production against mineral diesel, process intensification has been studied for numerous biodiesel processing technologies. Subsequently, reactive extraction or in situ transesterification is actively being explored in which the solid oil-bearing seeds are used as the reactant directly with short-chain alcohol. This eliminates separate oil extraction process and combines both extraction and transesterification in a single unit. Supercritical reactive extraction takes one step further by substituting the role of catalyst with supercritical conditions to achieve higher yield and shorter processing time. In this work, supercritical reactive extraction with methanol was carried out in a high-pressure batch reactor to produce fatty acid methyl esters (FAMEs) from Jatropha curcas L. seeds. Material and process parameters including space loading, solvent to seed ratio, co-solvent (n-hexane) to seed ratio, reaction temperature, reaction time and mixing intensity were varied one at a time and optimized based on two responses i.e. extraction efficiency, M extract and FAME yield, F y . The optimum responses for supercritical reactive extraction obtained were 104.17% w/w and 99.67% w/w (relative to 100% lipid extraction with n-hexane) for M extract and F y respectively under the following conditions: 54.0 ml/g space loading, 5.0 ml/g methanol to seeds ratio, 300 °C, 9.5 MPa (Mega Pascal), 30 min reaction time and without n-hexane as co-solvent or any agitation source. This proved that

  11. LiDAR DTMs and anthropogenic feature extraction: testing the feasibility of geomorphometric parameters in floodplains

    Science.gov (United States)

    Sofia, G.; Tarolli, P.; Dalla Fontana, G.

    2012-04-01

    resolution topography have been proven to be reliable for feasible applications. The use of statistical operators as thresholds for these geomorphic parameters, furthermore, showed a high reliability for feature extraction in mountainous environments. The goal of this research is to test if these morphological indicators and objective thresholds can be feasible also in floodplains, where features assume different characteristics and other artificial disturbances might be present. In the work, three different geomorphic parameters are tested and applied at different scales on a LiDAR DTM of typical alluvial plain's area in the North East of Italy. The box-plot is applied to identify the threshold for feature extraction, and a filtering procedure is proposed, to improve the quality of the final results. The effectiveness of the different geomorphic parameters is analyzed, comparing automatically derived features with the surveyed ones. The results highlight the capability of high resolution topography, geomorphic indicators and statistical thresholds for anthropogenic features extraction and characterization in a floodplains context.

  12. Homogenization of metamaterials: Parameters retrieval methods and intrinsic problems

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Malureanu, Radu; Lavrinenko, Andrei

    2010-01-01

    Metamaterials (MTMs) claim a lot of attention worldwide. Description of the MTMs in terms of effective parameters is a simple and useful tool for characterisation of their electromagnetic properties. So a reliable effective parameters restoration method is on demand. In this paper we report about...

  13. An automatic and effective parameter optimization method for model tuning

    Directory of Open Access Journals (Sweden)

    T. Zhang

    2015-11-01

    simulation results show that the optimum combination of these parameters determined using this method is able to improve the model's overall performance by 9 %. The proposed methodology and software framework can be easily applied to other GCMs to speed up the model development process, especially regarding unavoidable comprehensive parameter tuning during the model development stage.

  14. Method of extraction under pressure of fossil material

    Energy Technology Data Exchange (ETDEWEB)

    Fredenmark, G L

    1942-02-24

    A method is described of extraction under pressure of fossil material, such as coal, brown coal (lignite), peat, oil shale. It is characterized by carrying out the process of extraction by utilization of fractions of shale oils and/or peat tar with a boiling point above 170/sup 0/C and under such as pressure that the medium of extraction is in a liquid state.

  15. A Parameter Robust Method for Singularly Perturbed Delay Differential Equations

    Directory of Open Access Journals (Sweden)

    Erdogan Fevzi

    2010-01-01

    Full Text Available Uniform finite difference methods are constructed via nonstandard finite difference methods for the numerical solution of singularly perturbed quasilinear initial value problem for delay differential equations. A numerical method is constructed for this problem which involves the appropriate Bakhvalov meshes on each time subinterval. The method is shown to be uniformly convergent with respect to the perturbation parameter. A numerical example is solved using the presented method, and the computed result is compared with exact solution of the problem.

  16. Safety Profile of Meswak Root Extract on Liver, Kidney, Sexual Hormones and Hematological Parameters of Rats

    Directory of Open Access Journals (Sweden)

    Abeer Y. IBRAHIM

    2012-02-01

    Full Text Available This study was conducted to investigate the safety profile of Salvadora persica (Salvadoraceae aqueous alcoholic root extract by carrying out acute and sub-chronic toxicity assessment in order to find out any side effect of the traditionally using of these root sticks. Regarding to acute toxicity test, mice were administered the extract up to 5 g kg-1, intraperitoneally. Animals were then observed for behavioural changes; signs of toxicity, and mortality within 24 h. Surviving mice were monitored for 7 days for signs of delayed toxicity. In the sub-chronic toxicity test, rats were daily treated with the extract at a dose of 400 mg kg-1 intraperitoneally, for 30 days. At the end of the test period, hematological and biochemical parameters were determined in blood and serum samples with determination of vital organs weights. In the acute toxicity test, the extract was practically non-toxic showing no mortality and visible signs of delayed toxicity. The LD50, given intraperitoneally, was estimated to be 4 g kg-1. Administration of extract (at a dose of 400 mg Kg-1 b.wt. to male and female rats for 30 days did not produce any significant (P < 0.05 effect on hematological and most biochemical parameters also vital organs weights. The root extract showed adverse effects on sexual hormones, by increasing estrogen secretion and reducing testosterone level in male rats. At the same time, the extract reduces progesterone level in female satellite group. Overall, Meswak aqueous extract is safe concerning liver and kidney functions and hematological assessments; however, it induces reversal effect on sexual hormones levels determined in sera.

  17. Optimization of Extraction Parameters of Phenolic Compounds from Sarcopoterium spinosum Leaves by Response Surface Methodology

    Directory of Open Access Journals (Sweden)

    Ceren Sunguc

    2017-07-01

    Full Text Available The shrublands are very common in Urla-Çeşme-Karaburun peninsula located in the western point of Turkey. Prickly shrubby burnet (Sarcopoterium spinosum L. is one of the common weed which has intensive thorns making its consumption for the local domestic animals. However, Sarcopoterium spinosum is a valuable and common medicinal plant in the Mediterranean region. Crude extract of S. spinosum leaves exhibited higher antioxidant activity, as 3143.5± 238.5 µM TEAC (Trolox Equivalent Antioxidant Capacity/g dry weight (DW, when compared to other medicinal plants found in the literature. The aim of this study was to determine the effect of extraction parameters on the content and biological activity of the extract by response surface methodology (RSM as well as to identify its major compounds. High Performance Liquid Chromatography (HPLC was employed to investigate the phenolic content of S. spinosum extract. The composition of the phenolic contents including hyperoside and isoquercetin, the latter being the major component, in S. spinosum extract has been shown for the first time by HPLC. Antimicrobial activity of S. spinosum extract, identified by minimum inhibition concentration (MIC assay, indicated that the crude extract had antifungal activity against Candida albicans.

  18. Assessment of proposed electromagnetic quantum vacuum energy extraction methods

    OpenAIRE

    Moddel, Garret

    2009-01-01

    In research articles and patents several methods have been proposed for the extraction of zero-point energy from the vacuum. None has been reliably demonstrated, but the proposals remain largely unchallenged. In this paper the feasibility of these methods is assessed in terms of underlying thermodynamics principles of equilibrium, detailed balance, and conservation laws. The methods are separated into three classes: nonlinear processing of the zero-point field, mechanical extraction using Cas...

  19. METAHEURISTIC OPTIMIZATION METHODS FOR PARAMETERS ESTIMATION OF DYNAMIC SYSTEMS

    Directory of Open Access Journals (Sweden)

    V. Panteleev Andrei

    2017-01-01

    Full Text Available The article considers the usage of metaheuristic methods of constrained global optimization: “Big Bang - Big Crunch”, “Fireworks Algorithm”, “Grenade Explosion Method” in parameters of dynamic systems estimation, described with algebraic-differential equations. Parameters estimation is based upon the observation results from mathematical model behavior. Their values are derived after criterion minimization, which describes the total squared error of state vector coordinates from the deduced ones with precise values observation at different periods of time. Paral- lelepiped type restriction is imposed on the parameters values. Used for solving problems, metaheuristic methods of constrained global extremum don’t guarantee the result, but allow to get a solution of a rather good quality in accepta- ble amount of time. The algorithm of using metaheuristic methods is given. Alongside with the obvious methods for solving algebraic-differential equation systems, it is convenient to use implicit methods for solving ordinary differen- tial equation systems. Two ways of solving the problem of parameters evaluation are given, those parameters differ in their mathematical model. In the first example, a linear mathematical model describes the chemical action parameters change, and in the second one, a nonlinear mathematical model describes predator-prey dynamics, which characterize the changes in both kinds’ population. For each of the observed examples there are calculation results from all the three methods of optimization, there are also some recommendations for how to choose methods parameters. The obtained numerical results have demonstrated the efficiency of the proposed approach. The deduced parameters ap- proximate points slightly differ from the best known solutions, which were deduced differently. To refine the results one should apply hybrid schemes that combine classical methods of optimization of zero, first and second orders and

  20. Development of an extraction method for perchlorate in soils.

    Science.gov (United States)

    Cañas, Jaclyn E; Patel, Rashila; Tian, Kang; Anderson, Todd A

    2006-03-01

    Perchlorate originates as a contaminant in the environment from its use in solid rocket fuels and munitions. The current US EPA methods for perchlorate determination via ion chromatography using conductivity detection do not include recommendations for the extraction of perchlorate from soil. This study evaluated and identified appropriate conditions for the extraction of perchlorate from clay loam, loamy sand, and sandy soils. Based on the results of this evaluation, soils should be extracted in a dry, ground (mortar and pestle) state with Milli-Q water in a 1 ratio 1 soil ratio water ratio and diluted no more than 5-fold before analysis. When sandy soils were extracted in this manner, the calculated method detection limit was 3.5 microg kg(-1). The findings of this study have aided in the establishment of a standardized extraction method for perchlorate in soil.

  1. Tuning Parameters in Heuristics by Using Design of Experiments Methods

    Science.gov (United States)

    Arin, Arif; Rabadi, Ghaith; Unal, Resit

    2010-01-01

    With the growing complexity of today's large scale problems, it has become more difficult to find optimal solutions by using exact mathematical methods. The need to find near-optimal solutions in an acceptable time frame requires heuristic approaches. In many cases, however, most heuristics have several parameters that need to be "tuned" before they can reach good results. The problem then turns into "finding best parameter setting" for the heuristics to solve the problems efficiently and timely. One-Factor-At-a-Time (OFAT) approach for parameter tuning neglects the interactions between parameters. Design of Experiments (DOE) tools can be instead employed to tune the parameters more effectively. In this paper, we seek the best parameter setting for a Genetic Algorithm (GA) to solve the single machine total weighted tardiness problem in which n jobs must be scheduled on a single machine without preemption, and the objective is to minimize the total weighted tardiness. Benchmark instances for the problem are available in the literature. To fine tune the GA parameters in the most efficient way, we compare multiple DOE models including 2-level (2k ) full factorial design, orthogonal array design, central composite design, D-optimal design and signal-to-noise (SIN) ratios. In each DOE method, a mathematical model is created using regression analysis, and solved to obtain the best parameter setting. After verification runs using the tuned parameter setting, the preliminary results for optimal solutions of multiple instances were found efficiently.

  2. AN IMPROVED INTERFEROMETRIC CALIBRATION METHOD BASED ON INDEPENDENT PARAMETER DECOMPOSITION

    Directory of Open Access Journals (Sweden)

    J. Fan

    2018-04-01

    Full Text Available Interferometric SAR is sensitive to earth surface undulation. The accuracy of interferometric parameters plays a significant role in precise digital elevation model (DEM. The interferometric calibration is to obtain high-precision global DEM by calculating the interferometric parameters using ground control points (GCPs. However, interferometric parameters are always calculated jointly, making them difficult to decompose precisely. In this paper, we propose an interferometric calibration method based on independent parameter decomposition (IPD. Firstly, the parameters related to the interferometric SAR measurement are determined based on the three-dimensional reconstruction model. Secondly, the sensitivity of interferometric parameters is quantitatively analyzed after the geometric parameters are completely decomposed. Finally, each interferometric parameter is calculated based on IPD and interferometric calibration model is established. We take Weinan of Shanxi province as an example and choose 4 TerraDEM-X image pairs to carry out interferometric calibration experiment. The results show that the elevation accuracy of all SAR images is better than 2.54 m after interferometric calibration. Furthermore, the proposed method can obtain the accuracy of DEM products better than 2.43 m in the flat area and 6.97 m in the mountainous area, which can prove the correctness and effectiveness of the proposed IPD based interferometric calibration method. The results provide a technical basis for topographic mapping of 1 : 50000 and even larger scale in the flat area and mountainous area.

  3. An Improved Interferometric Calibration Method Based on Independent Parameter Decomposition

    Science.gov (United States)

    Fan, J.; Zuo, X.; Li, T.; Chen, Q.; Geng, X.

    2018-04-01

    Interferometric SAR is sensitive to earth surface undulation. The accuracy of interferometric parameters plays a significant role in precise digital elevation model (DEM). The interferometric calibration is to obtain high-precision global DEM by calculating the interferometric parameters using ground control points (GCPs). However, interferometric parameters are always calculated jointly, making them difficult to decompose precisely. In this paper, we propose an interferometric calibration method based on independent parameter decomposition (IPD). Firstly, the parameters related to the interferometric SAR measurement are determined based on the three-dimensional reconstruction model. Secondly, the sensitivity of interferometric parameters is quantitatively analyzed after the geometric parameters are completely decomposed. Finally, each interferometric parameter is calculated based on IPD and interferometric calibration model is established. We take Weinan of Shanxi province as an example and choose 4 TerraDEM-X image pairs to carry out interferometric calibration experiment. The results show that the elevation accuracy of all SAR images is better than 2.54 m after interferometric calibration. Furthermore, the proposed method can obtain the accuracy of DEM products better than 2.43 m in the flat area and 6.97 m in the mountainous area, which can prove the correctness and effectiveness of the proposed IPD based interferometric calibration method. The results provide a technical basis for topographic mapping of 1 : 50000 and even larger scale in the flat area and mountainous area.

  4. Evaluation of pomegranate rind (Punica granatum hydroethanolic extract on blood parameters in male mice treated by Irinotecan Hcl

    Directory of Open Access Journals (Sweden)

    N Mirazi

    2015-05-01

    Full Text Available Background & aim: Irinotecan Hcl is the first order drug for some neoplasm treatment in patients. Irinotecan Hcl has side effects on blood such as anemia and leukopeny. The aim of this study was to evaluate erythropoetic effects of the pomegranate hydroethanolic extract were examined on mice which treated by irinotecan Hcl. Methods: In this experimental study, 49 male mice (25-30 g were divided in 7 groups (control, sham, treated by irinotecan Hcl (100 mg/kg, treated by pomegranate extract (100 and 400 mg/kg, i.p, daily for one week and treated by irinotecan Hcl plus pomegranate extract (100 and 400 mg/kg, i.p, daily for one week randomly. Anemia induced by administration of irinotecan in the experimental animal. At the end of experiment the blood samples were collected by cardiac puncture method and analized for RBC, WBC, Hb, Hct parameters. Data were analyzed using one-way ANOVA and Tukey’s test. Results: The results of this study showed that irinotecan has affected on blood factors and cause to significance decrese compared with control group (p<0.001. Also groups which treated with pomegranate extract (100 and 400 mg/kg significantly reduce the side effects of irinotecan and cause to increasing in blood factors (p<0.001. The number of WBC counts in the group which received Irinotecan (100 kg significantly decreased as compared with the control group (p<0.001. Irinotecan affected on blood Hb level and cause to significant decrease compared with control group. Groups which received pomegranate extract (100 and 400 kg had positive effect and significantly increased the blood Hb levels as compared to controls (p<0.001. Conclusion: These results showed that consumption of pomegranate rind extract in a dose-dependent manner has protective effect on blood parameters in mice which treated with Irinotecan Hcl.

  5. A method for generating subgroup parameters from resonance tables

    International Nuclear Information System (INIS)

    Devan, K.; Mohanakrishnan, P.

    1993-01-01

    A method for generating subgroup or band parameters from resonance tables is described. A computer code SPART was written using this method. This code generates the subgroup parameters for any number of bands within the specified broad groups at different temperatures by reading the required input data from the binary cross section library in the Cadarache format. The results obtained with SPART code for two bands were compared with that obtained from GROUPIE code and a good agreement was obtained. Results of the generation of subgroup parameters in four bands for sample case of 239 Pu from resonance tables of Cadarache Ver.2 library is also presented. (author). 8 refs., 2 tabs

  6. Effects of Extraction Method on the Physicochemical and ...

    African Journals Online (AJOL)

    The effects of improved method of extraction on the physicochemical, mycological and stability of crude Canarium Schweinfurthii fruit oil were studied. The extracted oils were then stored at 25±5oC for 24 months with samples analyzed at 6months interval for; pH, saponification value, acid value, peroxide value and iodine ...

  7. Comparison of protein extraction methods suitable for proteomics ...

    African Journals Online (AJOL)

    An efficient protein extraction method is a prerequisite for successful implementation of proteomics. In this study, seedling roots of Jerusalem artichoke were treated with the concentration of 250 mM NaCl for 36 h. Subsequently, six different protocols of protein extraction were applied to seedling roots of Jerusalem artichoke ...

  8. A Novel Nonlinear Parameter Estimation Method of Soft Tissues

    Directory of Open Access Journals (Sweden)

    Qianqian Tong

    2017-12-01

    Full Text Available The elastic parameters of soft tissues are important for medical diagnosis and virtual surgery simulation. In this study, we propose a novel nonlinear parameter estimation method for soft tissues. Firstly, an in-house data acquisition platform was used to obtain external forces and their corresponding deformation values. To provide highly precise data for estimating nonlinear parameters, the measured forces were corrected using the constructed weighted combination forecasting model based on a support vector machine (WCFM_SVM. Secondly, a tetrahedral finite element parameter estimation model was established to describe the physical characteristics of soft tissues, using the substitution parameters of Young’s modulus and Poisson’s ratio to avoid solving complicated nonlinear problems. To improve the robustness of our model and avoid poor local minima, the initial parameters solved by a linear finite element model were introduced into the parameter estimation model. Finally, a self-adapting Levenberg–Marquardt (LM algorithm was presented, which is capable of adaptively adjusting iterative parameters to solve the established parameter estimation model. The maximum absolute error of our WCFM_SVM model was less than 0.03 Newton, resulting in more accurate forces in comparison with other correction models tested. The maximum absolute error between the calculated and measured nodal displacements was less than 1.5 mm, demonstrating that our nonlinear parameters are precise.

  9. Performance analysis of pin fins with temperature dependent thermal parameters using the variation of parameters method

    Directory of Open Access Journals (Sweden)

    Cihat Arslantürk

    2016-08-01

    Full Text Available The performance of pin fins transferring heat by convection and radiation and having variable thermal conductivity, variable emissivity and variable heat transfer coefficient was investigated in the present paper. Nondimensionalizing the fin equation, the problem parameters which affect the fin performance were obtained. Dimensionless nonlinear fin equation was solved with the variation of parameters method, which is quite new in the solution of nonlinear heat transfer problems. The solution of variation of parameters method was compared with known analytical solutions and some numerical solution. The comparisons showed that the solutions are seen to be perfectly compatible. The effects of problem parameters were investigated on the heat transfer rate and fin efficiency and results were presented graphically.

  10. Identification of PV solar cells and modules parameters using the genetic algorithms: Application to maximum power extraction

    Energy Technology Data Exchange (ETDEWEB)

    Zagrouba, M.; Sellami, A.; Bouaicha, M. [Laboratoire de Photovoltaique, des Semi-conducteurs et des Nanostructures, Centre de Recherches et des Technologies de l' Energie, Technopole de Borj-Cedria, Tunis, B.P. 95, 2050 Hammam-Lif (Tunisia); Ksouri, M. [Unite de Recherche RME-Groupe AIA, Institut National des Sciences Appliquees et de Technologie (Tunisia)

    2010-05-15

    In this paper, we propose to perform a numerical technique based on genetic algorithms (GAs) to identify the electrical parameters (I{sub s}, I{sub ph}, R{sub s}, R{sub sh}, and n) of photovoltaic (PV) solar cells and modules. These parameters were used to determine the corresponding maximum power point (MPP) from the illuminated current-voltage (I-V) characteristic. The one diode type approach is used to model the AM1.5 I-V characteristic of the solar cell. To extract electrical parameters, the approach is formulated as a non convex optimization problem. The GAs approach was used as a numerical technique in order to overcome problems involved in the local minima in the case of non convex optimization criteria. Compared to other methods, we find that the GAs is a very efficient technique to estimate the electrical parameters of PV solar cells and modules. Indeed, the race of the algorithm stopped after five generations in the case of PV solar cells and seven generations in the case of PV modules. The identified parameters are then used to extract the maximum power working points for both cell and module. (author)

  11. Experimentally verified inductance extraction and parameter study for superconductive integrated circuit wires crossing ground plane holes

    International Nuclear Information System (INIS)

    Fourie, Coenrad J; Wetzstein, Olaf; Kunert, Juergen; Meyer, Hans-Georg; Toepfer, Hannes

    2013-01-01

    As the complexity of rapid single flux quantum (RSFQ) circuits increases, both current and power consumption of the circuits become important design criteria. Various new concepts such as inductive biasing for energy efficient RSFQ circuits and inductively coupled RSFQ cells for current recycling have been proposed to overcome increasingly severe design problems. Both of these techniques use ground plane holes to increase the inductance or coupling factor of superconducting integrated circuit wires. New design tools are consequently required to handle the new topographies. One important issue in such circuit design is the accurate calculation of networks of inductances even in the presence of finite holes in the ground plane. We show how a fast network extraction method using InductEx, which is a pre- and post-processor for the magnetoquasistatic field solver FastHenry, is used to calculate the inductances of a set of SQUIDs (superconducting quantum interference devices) with ground plane holes of different sizes. The results are compared to measurements of physical structures fabricated with the IPHT Jena 1 kA cm −2 RSFQ niobium process to verify accuracy. We then do a parameter study and derive empirical equations for fast and useful estimation of the inductance of wires surrounded by ground plane holes. We also investigate practical circuits and show excellent accuracy. (paper)

  12. Chemical Compounds and Extraction Methods of ?Maollahm?

    OpenAIRE

    Sadeghpoor, Omid; Dayeni, Manijeh; Razi, Samane

    2016-01-01

    Background: Maollahm or meat juice, a by-product of meat, is a traditional remedy in Persian medicine. This product was used as a nourishment or treatment substance for sick people. According to the ancient Persian medicine, animal meat has more affinity with the human body and the body easily absorbs its nutrition. Therefore, one could resort to maollahm for patients requiring urgent nourishment to boost and strengthen their body. Methods: In this work, different ways of preparing maollahm f...

  13. Microbial diversity in fecal samples depends on DNA extraction method

    DEFF Research Database (Denmark)

    Mirsepasi, Hengameh; Persson, Søren; Struve, Carsten

    2014-01-01

    was to evaluate two different DNA extraction methods in order to choose the most efficient method for studying intestinal bacterial diversity using Denaturing Gradient Gel Electrophoresis (DGGE). FINDINGS: In this study, a semi-automatic DNA extraction system (easyMag®, BioMérieux, Marcy I'Etoile, France......BACKGROUND: There are challenges, when extracting bacterial DNA from specimens for molecular diagnostics, since fecal samples also contain DNA from human cells and many different substances derived from food, cell residues and medication that can inhibit downstream PCR. The purpose of the study...... by easyMag® from the same fecal samples. Furthermore, DNA extracts obtained using easyMag® seemed to contain inhibitory compounds, since in order to perform a successful PCR-analysis, the sample should be diluted at least 10 times. DGGE performed on PCR from DNA extracted by QIAamp DNA Stool Mini Kit DNA...

  14. A novel validation algorithm allows for automated cell tracking and the extraction of biologically meaningful parameters.

    Directory of Open Access Journals (Sweden)

    Daniel H Rapoport

    Full Text Available Automated microscopy is currently the only method to non-invasively and label-free observe complex multi-cellular processes, such as cell migration, cell cycle, and cell differentiation. Extracting biological information from a time-series of micrographs requires each cell to be recognized and followed through sequential microscopic snapshots. Although recent attempts to automatize this process resulted in ever improving cell detection rates, manual identification of identical cells is still the most reliable technique. However, its tedious and subjective nature prevented tracking from becoming a standardized tool for the investigation of cell cultures. Here, we present a novel method to accomplish automated cell tracking with a reliability comparable to manual tracking. Previously, automated cell tracking could not rival the reliability of manual tracking because, in contrast to the human way of solving this task, none of the algorithms had an independent quality control mechanism; they missed validation. Thus, instead of trying to improve the cell detection or tracking rates, we proceeded from the idea to automatically inspect the tracking results and accept only those of high trustworthiness, while rejecting all other results. This validation algorithm works independently of the quality of cell detection and tracking through a systematic search for tracking errors. It is based only on very general assumptions about the spatiotemporal contiguity of cell paths. While traditional tracking often aims to yield genealogic information about single cells, the natural outcome of a validated cell tracking algorithm turns out to be a set of complete, but often unconnected cell paths, i.e. records of cells from mitosis to mitosis. This is a consequence of the fact that the validation algorithm takes complete paths as the unit of rejection/acceptance. The resulting set of complete paths can be used to automatically extract important biological parameters

  15. Comparison of protein extraction methods suitable for proteomics ...

    African Journals Online (AJOL)

    Jane

    2011-07-27

    Jul 27, 2011 ... An efficient protein extraction method is a prerequisite for successful implementation of proteomics. ... research, it is noteworthy to discover a proteome ..... Proteomic analysis of rice (Oryza sativa) seeds during germination.

  16. effects of extraction method on the physicochemical and mycological

    African Journals Online (AJOL)

    DR. AMINU

    Canarium Schweinfurthii fruit oil obtained by the improved method of extraction had better quality and stability ... application due to the believe that it enhances the oil flavours, also the fruit ..... starters on coconut oil recovery. Proceeding.

  17. Solid phase extraction method for determination of mitragynine in ...

    African Journals Online (AJOL)

    All rights reserved. ... 1Department of Pharmacology, 2Department of Applied Science, 3Police Forensic Science Center 10, Yala 95000, 4Natural ... Purpose: To develop a solid phase extraction (SPE) method that utilizes reverse-phase high.

  18. Dual ant colony operational modal analysis parameter estimation method

    Science.gov (United States)

    Sitarz, Piotr; Powałka, Bartosz

    2018-01-01

    Operational Modal Analysis (OMA) is a common technique used to examine the dynamic properties of a system. Contrary to experimental modal analysis, the input signal is generated in object ambient environment. Operational modal analysis mainly aims at determining the number of pole pairs and at estimating modal parameters. Many methods are used for parameter identification. Some methods operate in time while others in frequency domain. The former use correlation functions, the latter - spectral density functions. However, while some methods require the user to select poles from a stabilisation diagram, others try to automate the selection process. Dual ant colony operational modal analysis parameter estimation method (DAC-OMA) presents a new approach to the problem, avoiding issues involved in the stabilisation diagram. The presented algorithm is fully automated. It uses deterministic methods to define the interval of estimated parameters, thus reducing the problem to optimisation task which is conducted with dedicated software based on ant colony optimisation algorithm. The combination of deterministic methods restricting parameter intervals and artificial intelligence yields very good results, also for closely spaced modes and significantly varied mode shapes within one measurement point.

  19. Physical and chemical parameters of sediment extraction and fractionation that influence toxicity, as evaluated by microtox (trade name)

    International Nuclear Information System (INIS)

    Ho, K.T.Y.; Quinn, J.G.

    1993-01-01

    Several physical and chemical parameters of sediment extraction and fractionation of organic compounds that influence bioassay results were evaluated. Each parameter was evaluated with a photoluminescent bacterial bioassay (Microtox) as an end point. Three solvents (acetonitrile, acetone, and methanol) were studied for their ability to extract toxic organic components from marine sediments. Acetone extracted the most toxicity, with no difference between acetonitrile and methanol. Two methods of fractionating sediment extracts (silica-gel-column chromatography (SGCC) and acid-base fractionation) were compared. SGCC was more useful because it resulted in a wider range of responses and was faster to perform than acid-base fractionation. Microtox was used to rank four marine sediments with respect to toxicity and to determine if one chemical class (or fraction) was consistently more toxic among different sediments. With some caveats, Microtox results agreed with general chemical concentration trends and other bioassay results in distinguishing between contaminated and noncontaminated sediments. Although results indicated there was not a consistently most toxic fraction among sediments, there was a consistently least toxic fraction. The effect of sediment storage time on toxicity was also evaluated. Results indicated that the most stable chemical fraction (containing nonpolar hydrocarbons) did not change toxicologically for 30 weeks, whereas the more chemically active fraction (containing ketones, quinones, and carboxyls) changed as soon as one week

  20. Comparative analysis of different methods of extraction of present hydrocarbons in industrial residual waters

    International Nuclear Information System (INIS)

    Santa, Judith Rocio; Serrano, Martin; Stashenko, Elena

    2002-01-01

    A comparison among four extraction techniques such as: liquid - liquid (LLE) continuous and for lots, solid phase extraction (SPE), solid phase micro extraction (SPME) and static headspace (S-HS) was carried out. The main purpose of this research was to determine the highest recovery efficiencies and how reproducible the tests are while varying parameters such as time, extraction technique, type of solvents and others. Chromatographic parameters were optimized in order to carry out the analyses. Hydrocarbon's quantification of residual waters was achieved by using a high-resolution gas chromatography with a gas flame ionization detector (HRGC-FID). Validation of the method was carried out by analyzing real samples taken in different sampling places of the residual waters treatment plant of Ecopetrol - Barrancabermeja. The use of extraction methods that require big solvent quantities and long time for analysis are losing validity day by day. Techniques such as the HS-SPME and static HS are offered as alternatives for quantifying hydrocarbons. They show total lack of solvents, high sensibility, selectivity and the techniques are reproducible. Solid phase micro extraction (SPME) and static headspace (static HS) techniques were chosen as the extraction techniques to validate the method in real samples. Both techniques showed similar results for the determination of total hydrocarbons (in the gasoline range)

  1. Program for searching for semiempirical parameters by the MNDO method

    International Nuclear Information System (INIS)

    Bliznyuk, A.A.; Voityuk, A.A.

    1987-01-01

    The authors describe an program for optimizing atomic models constructed using the MNDO method which varies not only the parameters but also the scope for simple changes in the calculation scheme. The target function determines properties such as formation enthalpies, dipole moments, ionization potentials, and geometrical parameters. Software used to minimize the target function is based on the simplex method on the Nelder-Mead algorithm and on the Fletcher variable-metric method. The program is written in FORTRAN IV and implemented on the ES computer

  2. Extraction optimization and UHPLC method development for determination of the 20-hydroxyecdysone in Sida tuberculata leaves.

    Science.gov (United States)

    da Rosa, Hemerson S; Koetz, Mariana; Santos, Marí Castro; Jandrey, Elisa Helena Farias; Folmer, Vanderlei; Henriques, Amélia Teresinha; Mendez, Andreas Sebastian Loureiro

    2018-04-01

    Sida tuberculata (ST) is a Malvaceae species widely distributed in Southern Brazil. In traditional medicine, ST has been employed as hypoglycemic, hypocholesterolemic, anti-inflammatory and antimicrobial. Additionally, this species is chemically characterized by flavonoids, alkaloids and phytoecdysteroids mainly. The present work aimed to optimize the extractive technique and to validate an UHPLC method for the determination of 20-hydroxyecdsone (20HE) in the ST leaves. Box-Behnken Design (BBD) was used in method optimization. The extractive methods tested were: static and dynamic maceration, ultrasound, ultra-turrax and reflux. In the Box-Behnken three parameters were evaluated in three levels (-1, 0, +1), particle size, time and plant:solvent ratio. In validation method, the parameters of selectivity, specificity, linearity, limits of detection and quantification (LOD, LOQ), precision, accuracy and robustness were evaluated. The results indicate static maceration as better technique to obtain 20HE peak area in ST extract. The optimal extraction from surface response methodology was achieved with the parameters granulometry of 710 nm, 9 days of maceration and plant:solvent ratio 1:54 (w/v). The UHPLC-PDA analytical developed method showed full viability of performance, proving to be selective, linear, precise, accurate and robust for 20HE detection in ST leaves. The average content of 20HE was 0.56% per dry extract. Thus, the optimization of extractive method in ST leaves increased the concentration of 20HE in crude extract, and a reliable method was successfully developed according to validation requirements and in agreement with current legislation. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Extracting natural dyes from wool--an evaluation of extraction methods.

    Science.gov (United States)

    Manhita, Ana; Ferreira, Teresa; Candeias, António; Dias, Cristina Barrocas

    2011-05-01

    The efficiency of eight different procedures used for the extraction of natural dyes was evaluated using contemporary wool samples dyed with cochineal, madder, woad, weld, brazilwood and logwood. Comparison was made based on the LC-DAD peak areas of the natural dye's main components which had been extracted from the wool samples. Among the tested methods, an extraction procedure with Na(2)EDTA in water/DMF (1:1, v/v) proved to be the most suitable for the extraction of the studied dyes, which presented a wide range of chemical structures. The identification of the natural dyes used in the making of an eighteenth century Arraiolos carpet was possible using the Na(2)EDTA/DMF extraction of the wool embroidery samples and an LC-DAD-MS methodology. The effectiveness of the Na(2)EDTA/DMF extraction method was particularly observed in the extraction of weld dye components. Nine flavone derivatives previously identified in weld extracts could be identified in a single historical sample, confirming the use of this natural dye in the making of Arraiolos carpets. Indigo and brazilwood were also identified in the samples, and despite the fact that these natural dyes were referred in the historical recipes of Arraiolos dyeing, it is the first time that the use of brazilwood is confirmed. Mordant analysis by ICP-MS identified the widespread use of alum in the dyeing process, but in some samples with darker hues, high amounts of iron were found instead.

  4. Selection of propolis Tetragonula sp. extract solvent with flavonoids and polyphenols concentration and antioxidant activity parameters

    Science.gov (United States)

    Christina, Daisy; Hermansyah, Heri; Wijanarko, Anondho; Rohmatin, Etin; Sahlan, Muhamad; Pratami, Diah Kartika; Mun'im, Abdul

    2018-02-01

    Antioxidants are inhibitory compounds that can inhibit auto oxidation reaction by binding to free radicals and highly reactive molecules. The human body needs antioxidant. Antioxidants can be obtained from a variety of natural ingredients, including propolis. Propolis is the natural sap of the bees, obtained from the herbs around the honeycomb. Ethanol is the solvent that often used to extract propolis. Although it has many advantages, ethanol also has weaknesses such as intolerance to alcohol by some people. Therefore, this research was to extract propolis Tetragonula sp. coarse (C) and soft (S) using four varieties of organic solvent, i.e. olive oil (OO), virgin coconut oil (VCO), propylene glycol (PG), and lecithin (L). It was expected to get the best solvent in extracting propolis. The selection of the best solvent was determined by total flavonoids and polyphenols content assay and antioxidant activity. At each test, the absorbance value read by a microplate reader. Flavonoids content assay is using AlCl3 method with best result on rough-VCO propolis extract of 2509,767 ± 615,02 µg/mL. Polyphenols content assay was using Folin Ciocalteu method with the best results on soft-VCO propolis extract of 1391 ± 171.47 µg/mL. Antioxidant activity assay is using DPPH method with best result on soft-VCO propolis extract with IC50 value of 1,559 ± 0,222 µg/mL.

  5. Novel Method for 5G Systems NLOS Channels Parameter Estimation

    Directory of Open Access Journals (Sweden)

    Vladeta Milenkovic

    2017-01-01

    Full Text Available For the development of new 5G systems to operate in mm bands, there is a need for accurate radio propagation modelling at these bands. In this paper novel approach for NLOS channels parameter estimation will be presented. Estimation will be performed based on LCR performance measure, which will enable us to estimate propagation parameters in real time and to avoid weaknesses of ML and moment method estimation approaches.

  6. Effect of extraction method and orientin content on radio-protective effect of tulsi extracts

    Energy Technology Data Exchange (ETDEWEB)

    Tiwari, Mrinalini; Dwarakanath, B. S.; Agrawala, Paban K., E-mail: pkagrawal@gmail.com [Institute of Nuclear Medicine and Allied Sciences, Delhi (India); Murugan, R.; Parimelazhagan, T. [Department of Botany, Bharathiar University, Coimbatore (India); Uma Devi, P. [ARA-B-3SA, Plavilakonam,Trivandrum (India); Gota, V.; Sarin, R. K. [Advanced Centre for Treatment Research and Education in Cancer, Navi Mumbai (India)

    2014-07-01

    Extract of tulsi leaves (Ocimum sanctum) has been reported for its radioprotective efficacy. In our initial studies we observed significant variation in the survival of irradiated mice with different batches of tulsi extracts and therefore we employed different extraction methods on leaves collected during various seasons from different localities to study any variation in the radioprotective efficacy. Orientin, a component of tulsi extract, was considered a marker. Mice whole body survival (at 10 Gy lethal whole body irradiation) study and day 11 endo-CFU-s assay (at 5 Gy WBI) were performed employing 3 treatment schedules, 50 mg/kg or 25 mg/kg b.w (single injection, 30 min irradiation), and 10 mg/kgb.w (one injection per day for 5 day, last injection being 30 min before irradiation). Single dose of 25 mg/kg b.w (both aqueous and alcoholic) did not provide any significant survival benefit. The orientin concentrations in the extracts tested varied from 3.3 to 9.91 mg/g extract as studied by HPLC method. With a single administration (i.p) of 50 mg/kg, the aqueous extract from leaves of monsoon season had an orientin content of 9.91 mg/g extract and gave a survival of 60% with a CFU-s count of 37, while extract of leaf summer leaves had an orientin content of 4.15 mg/g extract and gave a survival of 50% with a CFU-s count of 11.6. At the same dose (50 mg/kg), the aqueous extract from the winter season had an orientin content of 3.30 mg/g extract and gave 25% survival with a CFU-s count of 19, while the ethanolic extract had an orientin content of 7.70 mg/g extract and gave a survival of 50% with a CFU-s count of 13. These observations suggest that different climatic factors, orientin content and the doses of administration are important factors regulating radioprotection afforded by different extracts of tulsi. (author)

  7. Chemical Compounds and Extraction Methods of "Maollahm".

    Science.gov (United States)

    Sadeghpoor, Omid; Dayeni, Manijeh; Razi, Samane

    2016-05-01

    Maollahm or meat juice, a by-product of meat, is a traditional remedy in Persian medicine. This product was used as a nourishment or treatment substance for sick people. According to the ancient Persian medicine, animal meat has more affinity with the human body and the body easily absorbs its nutrition. Therefore, one could resort to maollahm for patients requiring urgent nourishment to boost and strengthen their body. In this work, different ways of preparing maollahm from poultry, goat, cow, and sheep meat are studied. Most of these methods are based on distillation or barbecue before distillation, as prescribed by traditional medicine books. The reactions, chemical processes, and volatile compounds related to different types of cooked meat are also compared with the outcome of recent research studies. The difference between various types of meat is related to their compounds. Different cooking processes such as barbecuing, roasting, cooking, and boiling have an effect on the taste, smell and the chemical constituents of maollahm. Additionally, the type of meat, animal feed, as well as using or removing the fat during the cooking process, have an effect on the produced volatile compounds. Cooking process and the type of meat have a direct effect on the compounds of maollahm. Possible reactions in the preparation process of maollahm are investigated and presented according to the new research studies.

  8. Determination of resonance parameters in QCD by functional analysis methods

    International Nuclear Information System (INIS)

    Ciulli, S.; Geniet, F.; Papadopoulos, N.A.; Schilcher, K.

    1988-01-01

    A mathematically rigorous method based on functional analysis is used to determine resonance parameters of an amplitude from its given asymptotic expression in the space-like region. This method is checked on a model amplitude where both the asymptotic expression and the exact function are known. This method is then applied to the determination of the mass and the width of the ρ-meson from the corresponding space-like asymptotic QCD expression. (orig.)

  9. Effects of riverbed extraction on physico-chemical parameters of Tinau River, Nepal

    Directory of Open Access Journals (Sweden)

    K.R. Dahal

    2012-09-01

    Full Text Available This study was carried out during June 2010 to March 2011 in the Tinau River, Nepal. The level of pollution was determined based on the protocol of US EPA (Habitat Assessment Protocol. Riverbed extraction was occurring in very large scale in this river since 2002. Five sampling stations were selected to carry out the study. Some specific physico-chemical parameters like Electrical Conductivity (EC, Lead (Pb, pH, Iron (Fe, Phosphorous (P, Ammonia (NH4+, Nitrate (NO3-, Arsenic (As, Total Dissolved Solids (TDS were analyzed. Three major parameters (Pb, As and TDS were closely related to the riverbed extraction and exceeded the limit set by WHO for drinking water. Similar relationship was also seen for EC; however its concentrations did not exceed the limit of WHO. The river water was slightly alkaline based on the pH value (ranging from 7.5 to 9.Other parameters did not seem to be related to the riverbed extraction. However, the nitrate and phosphorous concentrations were also high during the present investigation. Lack of similar studies prevented us to compare the result; however these findings provide the baseline data for future work.

  10. Microalgae based biorefinery: evaluation of oil extraction methods in terms of efficiency, costs, toxicity and energy in lab-scale

    Directory of Open Access Journals (Sweden)

    Ángel Darío González-Delgado

    2013-06-01

    Full Text Available Several alternatives of microalgal metabolites extraction and transformation are being studied for achieving the total utilization of this energy crop of great interest worldwide. Microalgae oil extraction is a key stage in microalgal biodiesel production chains and their efficiency affects significantly the global process efficiency. In this study, a comparison of five oil extraction methods in lab-scale was made taking as additional parameters, besides extraction efficiency, the costs of method performing, energy requirements, and toxicity of solvents used, in order to elucidate the convenience of their incorporation to a microalgae-based topology of biorefinery. Methods analyzed were Solvent extraction assisted with high speed homogenization (SHE, Continuous reflux solvent extraction (CSE, Hexane based extraction (HBE, Cyclohexane based extraction (CBE and Ethanol-hexane extraction (EHE, for this evaluation were used the microalgae strains Nannochloropsis sp., Guinardia sp., Closterium sp., Amphiprora sp. and Navicula sp., obtained from a Colombian microalgae bioprospecting. In addition, morphological response of strains to oil extraction methods was also evaluated by optic microscopy. Results shows that although there is not a unique oil extraction method which excels in all parameters evaluated, CSE, SHE and HBE appears as promising alternatives, while HBE method is shown as the more convenient for using in lab-scale and potentially scalable for implementation in a microalgae based biorefinery

  11. A Karnaugh-Map based fingerprint minutiae extraction method

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Singla

    2010-07-01

    Full Text Available Fingerprint is one of the most promising method among all the biometric techniques and has been used for thepersonal authentication for a long time because of its wide acceptance and reliability. Features (Minutiae are extracted fromthe fingerprint in question and are compared with the features already stored in the database for authentication. Crossingnumber (CN is the most commonly used minutiae extraction method for fingerprints. In this paper, a new Karnaugh-Mapbased fingerprint minutiae extraction method has been proposed and discussed. In the proposed algorithm the 8 neighborsof a pixel in a 33 window are arranged as 8 bits of a byte and corresponding hexadecimal (hex value is calculated. Thesehex values are simplified using standard Karnaugh-Map (K-map technique to obtain the minimized logical expression.Experiments conducted on the FVC2002/Db1_a database reveals that the developed method is better than the crossingnumber (CN method.

  12. Effects of aqueous extract of Musa paradisiaca root on testicular function parameters of male rats.

    Science.gov (United States)

    Yakubu, Musa Toyin; Oyeyipo, Theo Oyetayo; Quadri, Ayodeji Luqman; Akanji, Musbau Adewumi

    2013-01-01

    There is an age-long claim that the Musa paradisiaca root is used to manage reproductive dysfunction, most especially sexual dysfunction (as an aphrodisiac), but there are no data in the open scientific literature that have refuted or supported this claim and the effects of M. paradisiaca root on the testes. Therefore, this study was aimed at investigating the effect of oral administration of the aqueous extract of M. paradisiaca root on the testicular function parameters of male rat testes. Sexually matured male albino rats (138.67±5.29 g) were randomly assigned into four groups, A, B, C, and D, that respectively received 0.5 mL (3.6 mL/kg body weight) of distilled water and 25, 50, and 100 mg/kg body weight of the extract, orally, once daily, for 14 days. The extract significantly increased (pparadisiaca root extract at doses of 25, 50, and 100 mg/kg body weight enhanced the testosterone-dependent normal functioning of the testes. Overall, the aqueous extract of M. paradisiaca stimulated the normal functioning of the testes and exhibited both androgenic and anabolic properties. The results may explain the rationale behind the folkloric beneficial effect of the plant in the management of reproductive dysfunction.

  13. EPIPOI: A user-friendly analytical tool for the extraction and visualization of temporal parameters from epidemiological time series

    Directory of Open Access Journals (Sweden)

    Alonso Wladimir J

    2012-11-01

    Full Text Available Abstract Background There is an increasing need for processing and understanding relevant information generated by the systematic collection of public health data over time. However, the analysis of those time series usually requires advanced modeling techniques, which are not necessarily mastered by staff, technicians and researchers working on public health and epidemiology. Here a user-friendly tool, EPIPOI, is presented that facilitates the exploration and extraction of parameters describing trends, seasonality and anomalies that characterize epidemiological processes. It also enables the inspection of those parameters across geographic regions. Although the visual exploration and extraction of relevant parameters from time series data is crucial in epidemiological research, until now it had been largely restricted to specialists. Methods EPIPOI is freely available software developed in Matlab (The Mathworks Inc that runs both on PC and Mac computers. Its friendly interface guides users intuitively through useful comparative analyses including the comparison of spatial patterns in temporal parameters. Results EPIPOI is able to handle complex analyses in an accessible way. A prototype has already been used to assist researchers in a variety of contexts from didactic use in public health workshops to the main analytical tool in published research. Conclusions EPIPOI can assist public health officials and students to explore time series data using a broad range of sophisticated analytical and visualization tools. It also provides an analytical environment where even advanced users can benefit by enabling a higher degree of control over model assumptions, such as those associated with detecting disease outbreaks and pandemics.

  14. Determination of material irradiation parameters. Required accuracies and available methods

    International Nuclear Information System (INIS)

    Cerles, J.M.; Mas, P.

    1978-01-01

    In this paper, the author reports some main methods to determine the nuclear parameters of material irradiation in testing reactor (nuclear power, burn-up, fluxes, fluences, ...). The different methods (theoretical or experimental) are reviewed: neutronics measurements and calculations, gamma scanning, thermal balance, ... The required accuracies are reviewed: they are of 3-5% on flux, fluences, nuclear power, burn-up, conversion factor, ... These required accuracies are compared with the real accuracies available which are at the present time of order of 5-20% on these parameters

  15. Determination of fuel irradiation parameters. Required accuracies and available methods

    International Nuclear Information System (INIS)

    Mas, P.

    1977-01-01

    This paper reports on the present point of some main methods to determine the nuclear parameters of fuel irradiation in testing reactors (nuclear power, burn up, ...) The different methods (theoretical or experimental) are reviewed: neutron measurements and calculations, gamma scanning, heat balance, ... . The required accuracies are reviewed: they are of 3-5 % on flux, fluences, nuclear power, burn-up, conversion factor. These required accuracies are compared with the real accuracies available which are the present time of order of 5-20 % on these parameters

  16. Statistical methods of parameter estimation for deterministically chaotic time series

    Science.gov (United States)

    Pisarenko, V. F.; Sornette, D.

    2004-03-01

    We discuss the possibility of applying some standard statistical methods (the least-square method, the maximum likelihood method, and the method of statistical moments for estimation of parameters) to deterministically chaotic low-dimensional dynamic system (the logistic map) containing an observational noise. A “segmentation fitting” maximum likelihood (ML) method is suggested to estimate the structural parameter of the logistic map along with the initial value x1 considered as an additional unknown parameter. The segmentation fitting method, called “piece-wise” ML, is similar in spirit but simpler and has smaller bias than the “multiple shooting” previously proposed. Comparisons with different previously proposed techniques on simulated numerical examples give favorable results (at least, for the investigated combinations of sample size N and noise level). Besides, unlike some suggested techniques, our method does not require the a priori knowledge of the noise variance. We also clarify the nature of the inherent difficulties in the statistical analysis of deterministically chaotic time series and the status of previously proposed Bayesian approaches. We note the trade off between the need of using a large number of data points in the ML analysis to decrease the bias (to guarantee consistency of the estimation) and the unstable nature of dynamical trajectories with exponentially fast loss of memory of the initial condition. The method of statistical moments for the estimation of the parameter of the logistic map is discussed. This method seems to be the unique method whose consistency for deterministically chaotic time series is proved so far theoretically (not only numerically).

  17. Identification of metabolic system parameters using global optimization methods

    Directory of Open Access Journals (Sweden)

    Gatzke Edward P

    2006-01-01

    Full Text Available Abstract Background The problem of estimating the parameters of dynamic models of complex biological systems from time series data is becoming increasingly important. Methods and results Particular consideration is given to metabolic systems that are formulated as Generalized Mass Action (GMA models. The estimation problem is posed as a global optimization task, for which novel techniques can be applied to determine the best set of parameter values given the measured responses of the biological system. The challenge is that this task is nonconvex. Nonetheless, deterministic optimization techniques can be used to find a global solution that best reconciles the model parameters and measurements. Specifically, the paper employs branch-and-bound principles to identify the best set of model parameters from observed time course data and illustrates this method with an existing model of the fermentation pathway in Saccharomyces cerevisiae. This is a relatively simple yet representative system with five dependent states and a total of 19 unknown parameters of which the values are to be determined. Conclusion The efficacy of the branch-and-reduce algorithm is illustrated by the S. cerevisiae example. The method described in this paper is likely to be widely applicable in the dynamic modeling of metabolic networks.

  18. An efficient method for DNA extraction from Cladosporioid fungi

    OpenAIRE

    Moslem, M.A.; Bahkali, A.H.; Abd-Elsalam, K.A.; Wit, de, P.J.G.M.

    2010-01-01

    We developed an efficient method for DNA extraction from Cladosporioid fungi, which are important fungal plant pathogens. The cell wall of Cladosporioid fungi is often melanized, which makes it difficult to extract DNA from their cells. In order to overcome this we grew these fungi for three days on agar plates and extracted DNA from mycelium mats after manual or electric homogenization. High-quality DNA was isolated, with an A260/A280 ratio ranging between 1.6 and 2.0. Isolated genomic DNA w...

  19. The influence of the extraction parameters on the quality of dried sugar beet pulp

    Directory of Open Access Journals (Sweden)

    Bogdanović Branislav V.

    2013-01-01

    Full Text Available Growing demand for better quality and cheaper products put on the need to industry to balance between the two kinds of needs, which are the reduction of production costs and to ensure a high quality product. This is the case with dried sugar beet pulp as a byproduct of sugar refining process. One of the possibilities to reduce energy consumption is savings in the process of thermal dehydration in the process of the conventional drying of pulp. Pulp drying is one third of total energy consumption in the sugar factory. Acidification of water extraction result in pulp that could be pressed better and in other hand in the juice with less non-sucrose compounds. Keeping the extraction process under certain conditions, directly affects on the quality of the extracted pulp and on effects of their further processing. This paper examines the impact of the extraction parameters of sugar from sugar beet and agents of acidification for water extraction (sulphurous acid, hydrogen peroxide on the quality of dried sugar beet pulp. Extraction of sugar from sugar beet cossettes by hydrogen peroxide at pH 5.5 to 8.5 does not cause changes in mechanical properties of sugar beet cossettes and in water retention coefficient, but increases the brightness of dried sugar beet pulp for about 5-7 units, which solubility in water does not depend on the applied concentration of extracting agents, but increases in dependence on the duration of the extraction. Sugar beet pulp extracted at pH 11.0 has reduced strength, they are highly hydrated, and under the force they lose their shape, binding a larger amount of water thus reducing the effect of their pressing. The changes in microstructure were probably accompanied by segmenting the linear parts of macromolecules and are reflected in the increase of water retention capacity and increase the solubility of dried sugar beet pulp for two to three times. Under the same conditions of extraction, sulphurous acid produces similar

  20. Inorganic arsenic in seafood: does the extraction method matter?

    Science.gov (United States)

    Pétursdóttir, Ásta H; Gunnlaugsdóttir, Helga; Krupp, Eva M; Feldmann, Jörg

    2014-05-01

    Nine different extraction methods were evaluated for three seafood samples to test whether the concentration of inorganic arsenic (iAs) determined in seafood is dependent on the extraction method. Certified reference materials (CRM) DOLT-4 (Dogfish Liver) and TORT-2 (Lobster Hepatopancreas), and a commercial herring fish meal were evaluated. All experimental work described here was carried out by the same operator using the same instrumentation, thus eliminating possible differences in results caused by laboratory related factors. Low concentrations of iAs were found in CRM DOLT-4 (0.012±0.003mgkg(-1)) and the herring fish meal sample (0.007±0.002mgkg(-1)) for all extraction methods. When comparing the concentration of iAs in CRM TORT-2 found in this study and in the literature dilute acids, HNO3 and HCl, showed the highest extracted iAs wheras dilute NaOH (in 50% ethanol) showed significantly lower extracted iAs. However, most other extraction solvents were not statistically different from one another. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Extraction methods of Amaranthus sp. grain oil isolation.

    Science.gov (United States)

    Krulj, Jelena; Brlek, Tea; Pezo, Lato; Brkljača, Jovana; Popović, Sanja; Zeković, Zoran; Bodroža Solarov, Marija

    2016-08-01

    Amaranthus sp. is a fast-growing crop with well-known beneficial nutritional values (rich in protein, fat, dietary fiber, ash, and minerals, especially calcium and sodium, and containing a higher amount of lysine than conventional cereals). Amaranthus sp. is an underexploited plant source of squalene, a compound of high importance in the food, cosmetic and pharmaceutical industries. This paper has examined the effects of the different extraction methods (Soxhlet, supercritical fluid and accelerated solvent extraction) on the oil and squalene yield of three genotypes of Amaranthus sp. grain. The highest yield of the extracted oil (78.1 g kg(-1) ) and squalene (4.7 g kg(-1) ) in grain was obtained by accelerated solvent extraction (ASE) in genotype 16. Post hoc Tukey's HSD test at 95% confidence limit showed significant differences between observed samples. Principal component analysis (PCA) and cluster analysis (CA) were used for assessing the effect of different genotypes and extraction methods on oil and squalene yield, and also the fatty acid composition profile. Using coupled PCA and CA of observed samples, possible directions for improving the quality of product can be realized. The results of this study indicate that it is very important to choose both the right genotype and the right method of extraction for optimal oil and squalene yield. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  2. METHOD OF RARE TERM CONTRASTIVE EXTRACTION FROM NATURAL LANGUAGE TEXTS

    Directory of Open Access Journals (Sweden)

    I. A. Bessmertny

    2017-01-01

    Full Text Available The paper considers a problem of automatic domain term extraction from documents corpus by means of a contrast collection. Existing contrastive methods successfully extract often used terms but mishandle rare terms. This could yield poorness of the resulting thesaurus. Assessment of point-wise mutual information is one of the known statistical methods of term extraction and it finds rare terms successfully. Although, it extracts many false terms at that. The proposed approach consists of point-wise mutual information application for rare terms extraction and filtering of candidates by criterion of joint occurrence with the other candidates. We build “documents-by-terms” matrix that is subjected to singular value decomposition to eliminate noise and reveal strong interconnections. Then we pass on to the resulting matrix “terms-by-terms” that reproduces strength of interconnections between words. This approach was approved on a documents collection from “Geology” domain with the use of contrast documents from such topics as “Politics”, “Culture”, “Economics” and “Accidents” on some Internet resources. The experimental results demonstrate operability of this method for rare terms extraction.

  3. Drilling methods to keep the hydrogeological parameters of natural aquifer

    International Nuclear Information System (INIS)

    Chen Xiaoqin

    2004-01-01

    In hydrogeological drilling, how to keep the hydrogeological parameters of natural aquifer unchanged is a deeply concerned problem for the technicians, this paper introduces the methods taken by the state-owned 'Red Hill' geological company of Uzbekistan. By the research and contrast of different kinds of flush liquid, the company has found the methods to reduce the negative effects of drilling on the permeability of the vicinal aquifer. (author)

  4. An effective method for extraction and polymerase chain reaction ...

    African Journals Online (AJOL)

    The PCR amplification with the NaOH and PBS treatment had a success rate of 30 to 100% for both mitochondrial and nuclear markers. The PBS method is the best method for extraction of DNA from formalin-preserved samples of longer period (two to seven years) because of higher success rate in amplifying mitochondrial ...

  5. The influence of supplementation with artichoke (Cynara scolymus L.) extract on selected redox parameters in rowers.

    Science.gov (United States)

    Skarpanska-Stejnborn, Anna; Pilaczynska-Szczesniak, Lucia; Basta, Piotr; Deskur-Smielcka, Ewa; Horoszkiewicz-Hassan, Magorzata

    2008-06-01

    High-intensity physical exercise decreases intracellular antioxidant potential. An enhanced antioxidant defense system is desirable in people subjected to exhaustive exercise. The aim of this study was to investigate the influence of supplementation with artichoke-leaf extract on parameters describing balance between oxidants and antioxidants in competitive rowers. This double-blinded study was carried out in 22 members of the Polish rowing team who were randomly assigned to a supplemented group (n = 12), receiving 1 gelatin capsule containing 400 mg of artichoke-leaf extract 3 times a day for 5 wk, or a placebo group (n = 10). At the beginning and end of the study participants performed a 2,000-m maximal test on a rowing ergometer. Before each exercise test, 1 min after the test completion, and after a 24-hr restitution period blood samples were taken from antecubital vein. The following redox parameters were assessed in red blood cells: superoxide dismutase activity, glutathione peroxidase activity, glutathione reductase activity, reduced glutathione levels, and thiobarbituric-acid-reactive-substances concentrations. Creatine kinase activity and total antioxidant capacity (TAC) were measured in plasma samples, lactate levels were determined in capillary blood samples, and serum lipid profiles were assessed. During restitution, plasma TAC was significantly higher (p artichoke-leaf extract, a natural vegetable preparation of high antioxidant potential, resulted in higher plasma TAC than placebo but did not limit oxidative damage to erythrocytes in competitive rowers subjected to strenuous training.

  6. Effect of interpolation on parameters extracted from seating interface pressure arrays.

    Science.gov (United States)

    Wininger, Michael; Crane, Barbara

    2014-01-01

    Interpolation is a common data processing step in the study of interface pressure data collected at the wheelchair seating interface. However, there has been no focused study on the effect of interpolation on features extracted from these pressure maps, nor on whether these parameters are sensitive to the manner in which the interpolation is implemented. Here, two different interpolation paradigms, bilinear versus bicubic spline, are tested for their influence on parameters extracted from pressure array data and compared against a conventional low-pass filtering operation. Additionally, analysis of the effect of tandem filtering and interpolation, as well as the interpolation degree (interpolating to 2, 4, and 8 times sampling density), was undertaken. The following recommendations are made regarding approaches that minimized distortion of features extracted from the pressure maps: (1) filter prior to interpolate (strong effect); (2) use of cubic interpolation versus linear (slight effect); and (3) nominal difference between interpolation orders of 2, 4, and 8 times (negligible effect). We invite other investigators to perform similar benchmark analyses on their own data in the interest of establishing a community consensus of best practices in pressure array data processing.

  7. Pose measurement method with six parameters for microassembly based on an optical micrometer

    Science.gov (United States)

    Ye, Xin; Wang, Qiang; Zhang, Zhi-jing; Sun, Yuan; Zhang, Xiao-feng

    2009-07-01

    This paper presents a new pose measurement method of microminiature parts that is capable of transforming one dimension (1D) contour size obtained by optical micrometer to three dimension (3D) data with six parameters for microassembly. Pose measurement is one of the most important processes for microminiature parts' alignment and insertion in microassembly. During the past few years, researchers have developed their microassembly systems focusing on visual identification to obtain two or three dimension data with no more than three parameters. Scanning electronic microscope (SEM), optical microscope, and stereomicroscope are applied in their systems. However, as structures of microminiature parts become increasingly complex, six parameters to represent their position and orientation are specifically needed. Firstly, The pose measurement model is established based on the introduction of measuring objects and measuring principle of optical micrometer. The measuring objects are microminiature parts with complex 3D structure. Two groups of two dimension (2D) data are gathered at two different measurement positions. Then part pose with 6 parameters is calculated, including 3 position parameters of feature point of the part and 3 orientation parameters of the part axis. Secondly, pose measurement process for a small shaft, vertical orientation determination, and position parameters obtaining are presented. 2D data is gathered by scanning the generatrix of the part, and valid data is extracted and saved in arrays. A vertical orientation criterion is proposed to determine whether the part is parallel to the Z-axis of the coordinate. If not, 2D data will be fixed into a linear equation using least square algorithm. Then orientation parameters are calculated. Center of Part End (CPE) is selected as feature point of the part, and its position parameters are extracted form two group of 2D data. Finally, a fast pose measurement device is developed and representative

  8. The Effect of Apium graveolens hydroalcoholic Seed Extract on Sperm Parameters and Serum Testosterone Concentration in Mice

    Directory of Open Access Journals (Sweden)

    P Kerishchi Khiabani

    2014-10-01

    Full Text Available Backgrounds & aim: apium graveolens contains antioxidant activity and high level of polyphenolics. The purpose of this study was to determaine the effect of Apium graveolens seeds extract on semen parameters and serum testosterone level in mice. Methods: In the present experimental study, sixty male mice were divided into three experimental groups and a control group. The hydroalcoholic seed extract of Apium graveolenas L. was administered intraperitoneally at the doses of 200, 400 and 800 mg/kg for 14 days. A week after the final injection, blood samples were collected for hormonal assay. Then, the testes weight, sperm count and cauda epididymal sperm motility was assessed. Data were analyzed by ANOVA and Tukey's test. Results: The results were compared with the control group indicating a significant increase in the total number of sperm at dose 400 mg.kg and increase sperm motility was seen in groups receiving 200 and 400 mg.kg respectively (P<0.001. Increased testosterone levels in the group receiving 400 mg.kg compared with the control group was observed (P<0.01. A significant increase was seen in testes weight compared with the control group (P<0.05. Conclusion: Apium graveolens seed extract appeared to be effective in improving semen parameters and serum total testosterones were dose dependent.

  9. Influence of Extraction Methods on the Yield of Steviol Glycosides and Antioxidants in Stevia rebaudiana Extracts.

    Science.gov (United States)

    Periche, Angela; Castelló, Maria Luisa; Heredia, Ana; Escriche, Isabel

    2015-06-01

    This study evaluated the application of ultrasound techniques and microwave energy, compared to conventional extraction methods (high temperatures at atmospheric pressure), for the solid-liquid extraction of steviol glycosides (sweeteners) and antioxidants (total phenols, flavonoids and antioxidant capacity) from dehydrated Stevia leaves. Different temperatures (from 50 to 100 °C), times (from 1 to 40 min) and microwave powers (1.98 and 3.30 W/g extract) were used. There was a great difference in the resulting yields according to the treatments applied. Steviol glycosides and antioxidants were negatively correlated; therefore, there is no single treatment suitable for obtaining the highest yield in both groups of compounds simultaneously. The greatest yield of steviol glycosides was obtained with microwave energy (3.30 W/g extract, 2 min), whereas, the conventional method (90 °C, 1 min) was the most suitable for antioxidant extraction. Consequently, the best process depends on the subsequent use (sweetener or antioxidant) of the aqueous extract of Stevia leaves.

  10. Deriving Animal Movement Behaviors Using Movement Parameters Extracted from Location Data

    Directory of Open Access Journals (Sweden)

    Maryam Teimouri

    2018-02-01

    Full Text Available We present a methodology for distinguishing between three types of animal movement behavior (foraging, resting, and walking based on high-frequency tracking data. For each animal we quantify an individual movement path. A movement path is a temporal sequence consisting of the steps through space taken by an animal. By selecting a set of appropriate movement parameters, we develop a method to assess movement behavioral states, reflected by changes in the movement parameters. The two fundamental tasks of our study are segmentation and clustering. By segmentation, we mean the partitioning of the trajectory into segments, which are homogeneous in terms of their movement parameters. By clustering, we mean grouping similar segments together according to their estimated movement parameters. The proposed method is evaluated using field observations (done by humans of movement behavior. We found that on average, our method agreed with the observational data (ground truth at a level of 80.75% ± 5.9% (SE.

  11. BMAA extraction of cyanobacteria samples: which method to choose?

    Science.gov (United States)

    Lage, Sandra; Burian, Alfred; Rasmussen, Ulla; Costa, Pedro Reis; Annadotter, Heléne; Godhe, Anna; Rydberg, Sara

    2016-01-01

    β-N-Methylamino-L-alanine (BMAA), a neurotoxin reportedly produced by cyanobacteria, diatoms and dinoflagellates, is proposed to be linked to the development of neurological diseases. BMAA has been found in aquatic and terrestrial ecosystems worldwide, both in its phytoplankton producers and in several invertebrate and vertebrate organisms that bioaccumulate it. LC-MS/MS is the most frequently used analytical technique in BMAA research due to its high selectivity, though consensus is lacking as to the best extraction method to apply. This study accordingly surveys the efficiency of three extraction methods regularly used in BMAA research to extract BMAA from cyanobacteria samples. The results obtained provide insights into possible reasons for the BMAA concentration discrepancies in previous publications. In addition and according to the method validation guidelines for analysing cyanotoxins, the TCA protein precipitation method, followed by AQC derivatization and LC-MS/MS analysis, is now validated for extracting protein-bound (after protein hydrolysis) and free BMAA from cyanobacteria matrix. BMAA biological variability was also tested through the extraction of diatom and cyanobacteria species, revealing a high variance in BMAA levels (0.0080-2.5797 μg g(-1) DW).

  12. A Facial Control Method Using Emotional Parameters in Sensibility Robot

    Science.gov (United States)

    Shibata, Hiroshi; Kanoh, Masayoshi; Kato, Shohei; Kunitachi, Tsutomu; Itoh, Hidenori

    The “Ifbot” robot communicates with people by considering its own “emotions”. Ifbot has many facial expressions to communicate enjoyment. These are used to express its internal emotions, purposes, reactions caused by external stimulus, and entertainment such as singing songs. All these facial expressions are developed by designers manually. Using this approach, we must design all facial motions, if we want Ifbot to express them. It, however, is not realistic. We have therefore developed a system which convert Ifbot's emotions to its facial expressions automatically. In this paper, we propose a method for creating Ifbot's facial expressions from parameters, emotional parameters, which handle its internal emotions computationally.

  13. Analysis of medicinal plant extracts by neutron activation method

    International Nuclear Information System (INIS)

    Vaz, Sandra Muntz

    1995-01-01

    This dissertation has presented the results from analysis of medicinal plant extracts using neutron activation method. Instrumental neutron activation analysis was applied to the determination of the elements Al, Br, Ca, Ce, Cl, Cr, Cs, Fe, K, La, Mg, Mn, Na, Rb, Sb, Sc and Zn in medicinal extracts obtained from Achyrolcline satureoides DC, Casearia sylvestris, Centella asiatica, Citrus aurantium L., Solano lycocarpum, Solidago microglossa, Stryphnondedron barbatiman and Zingiber officinale R. plants. The elements Hg and Se were determined using radiochemical separation by means of retention of Se in HMD inorganic exchanger and solvent extraction of Hg by bismuth diethyl-dithiocarbamate solution. Precision and accuracy of the results have been evaluated by analysing reference materials. The therapeutic action of some elements found in plant extracts analyzed was briefly discussed

  14. A novel method of genomic DNA extraction for Cactaceae1

    Science.gov (United States)

    Fehlberg, Shannon D.; Allen, Jessica M.; Church, Kathleen

    2013-01-01

    • Premise of the study: Genetic studies of Cactaceae can at times be impeded by difficult sampling logistics and/or high mucilage content in tissues. Simplifying sampling and DNA isolation through the use of cactus spines has not previously been investigated. • Methods and Results: Several protocols for extracting DNA from spines were tested and modified to maximize yield, amplification, and sequencing. Sampling of and extraction from spines resulted in a simplified protocol overall and complete avoidance of mucilage as compared to typical tissue extractions. Sequences from one nuclear and three plastid regions were obtained across eight genera and 20 species of cacti using DNA extracted from spines. • Conclusions: Genomic DNA useful for amplification and sequencing can be obtained from cactus spines. The protocols described here are valuable for any cactus species, but are particularly useful for investigators interested in sampling living collections, extensive field sampling, and/or conservation genetic studies. PMID:25202521

  15. MIT extraction method for measuring average subchannel axial velocities in reactor assemblies

    International Nuclear Information System (INIS)

    Hawley, J.T.; Chiu, C.; Todreas, N.E.

    1980-08-01

    The MIT extraction method for obtaining flow split data for individual subchannels is described in detail. An analysis of the method is presented which shows that isokinetic values of the subchannel flow rates are obtained directly even though the method is non-isokinetic. Time saving methods are discussed for obtaining the average value of the interior region flow split parameter. An analysis of the method at low bundle flow rates indicates that there is no inherent low flow rate limitation on the method and suggests a way to obtain laminar flow split data

  16. Parameters governing tritium extraction rates from lithiated ceramics. The case of lithium aluminate

    International Nuclear Information System (INIS)

    Roth, E.; Botter, F.; Briec, M.; Rasneur, B.; Roux, N.

    1986-10-01

    Significant discrepancies between results of authors comparing tritium extraction rates from different lithiated ceramics are found in the literature. Recent results obtained at C.E.A., principally on lithium aluminates, show that, for a given ceramic, parameters other than textural (grain size, porosity, etc...) may play a predominant role. Enhancements of extraction rates have been induced by adding MgO to the solid or H 2 and CO to the sweep gas, but other factors, probably related to the surface condition of samples, may produce even greater effects. Results of investigations of the influence of exposure to air at given partial pressures of water vapor or of CO 2 show that strict preirradiation procedures must be adopted for preparation, storage and handling of ceramic tritium breeders

  17. Exploring the effects of pulsed electric field processing parameters on polyacetylene extraction from carrot slices.

    Science.gov (United States)

    Aguiló-Aguayo, Ingrid; Abreu, Corina; Hossain, Mohammad B; Altisent, Rosa; Brunton, Nigel; Viñas, Inmaculada; Rai, Dilip K

    2015-03-02

    The effects of various pulsed electric field (PEF) parameters on the extraction of polyacetylenes from carrot slices were investigated. Optimised conditions with regard to electric field strength (1-4 kV/cm), number of pulses (100-1500), pulse frequency (10-200 Hz) and pulse width (10-30 μs) were identified using response surface methodology (RSM) to maximise the extraction of falcarinol (FaOH), falcarindiol (FaDOH) and falcarindiol-3-acetate (FaDOAc) from carrot slices. Data obtained from RSM and experiments fitted significantly (p pulses of 10 μs at 10 Hz. The predicted values from the developed quadratic polynomial equation were in close agreement with the actual experimental values with low average mean deviations (E%) ranging from 0.68% to 3.58%.

  18. Review of methods for level density estimation from resonance parameters

    International Nuclear Information System (INIS)

    Froehner, F.H.

    1983-01-01

    A number of methods are available for statistical analysis of resonance parameter sets, i.e. for estimation of level densities and average widths with account of missing levels. The main categories are (i) methods based on theories of level spacings (orthogonal-ensemble theory, Dyson-Mehta statistics), (ii) methods based on comparison with simulated cross section curves (Monte Carlo simulation, Garrison's autocorrelation method), (iii) methods exploiting the observed neutron width distribution by means of Bayesian or more approximate procedures such as maximum-likelihood, least-squares or moment methods, with various recipes for the treatment of detection thresholds and resolution effects. The present review will concentrate on (iii) with the aim of clarifying the basic mathematical concepts and the relationship between the various techniques. Recent theoretical progress in the treatment of resolution effects, detectability thresholds and p-wave admixture is described. (Auth.)

  19. SCoPE: an efficient method of Cosmological Parameter Estimation

    International Nuclear Information System (INIS)

    Das, Santanu; Souradeep, Tarun

    2014-01-01

    Markov Chain Monte Carlo (MCMC) sampler is widely used for cosmological parameter estimation from CMB and other data. However, due to the intrinsic serial nature of the MCMC sampler, convergence is often very slow. Here we present a fast and independently written Monte Carlo method for cosmological parameter estimation named as Slick Cosmological Parameter Estimator (SCoPE), that employs delayed rejection to increase the acceptance rate of a chain, and pre-fetching that helps an individual chain to run on parallel CPUs. An inter-chain covariance update is also incorporated to prevent clustering of the chains allowing faster and better mixing of the chains. We use an adaptive method for covariance calculation to calculate and update the covariance automatically as the chains progress. Our analysis shows that the acceptance probability of each step in SCoPE is more than 95% and the convergence of the chains are faster. Using SCoPE, we carry out some cosmological parameter estimations with different cosmological models using WMAP-9 and Planck results. One of the current research interests in cosmology is quantifying the nature of dark energy. We analyze the cosmological parameters from two illustrative commonly used parameterisations of dark energy models. We also asses primordial helium fraction in the universe can be constrained by the present CMB data from WMAP-9 and Planck. The results from our MCMC analysis on the one hand helps us to understand the workability of the SCoPE better, on the other hand it provides a completely independent estimation of cosmological parameters from WMAP-9 and Planck data

  20. A method for model identification and parameter estimation

    International Nuclear Information System (INIS)

    Bambach, M; Heinkenschloss, M; Herty, M

    2013-01-01

    We propose and analyze a new method for the identification of a parameter-dependent model that best describes a given system. This problem arises, for example, in the mathematical modeling of material behavior where several competing constitutive equations are available to describe a given material. In this case, the models are differential equations that arise from the different constitutive equations, and the unknown parameters are coefficients in the constitutive equations. One has to determine the best-suited constitutive equations for a given material and application from experiments. We assume that the true model is one of the N possible parameter-dependent models. To identify the correct model and the corresponding parameters, we can perform experiments, where for each experiment we prescribe an input to the system and observe a part of the system state. Our approach consists of two stages. In the first stage, for each pair of models we determine the experiment, i.e. system input and observation, that best differentiates between the two models, and measure the distance between the two models. Then we conduct N(N − 1) or, depending on the approach taken, N(N − 1)/2 experiments and use the result of the experiments as well as the previously computed model distances to determine the true model. We provide sufficient conditions on the model distances and measurement errors which guarantee that our approach identifies the correct model. Given the model, we identify the corresponding model parameters in the second stage. The problem in the second stage is a standard parameter estimation problem and we use a method suitable for the given application. We illustrate our approach on three examples, including one where the models are elliptic partial differential equations with different parameterized right-hand sides and an example where we identify the constitutive equation in a problem from computational viscoplasticity. (paper)

  1. Parameters Affecting the Extraction Process of Jatropha Curcas Oil Using a Single Screw Extruder

    OpenAIRE

    Siregar, Ali Nurrakhmad; Ghani, Jaharah A; Che Haron, Che Hassan; Rizal, Muhammad

    2015-01-01

    The most commonly used technique to separate oil and cake from J. curcas seeds is mechanical extraction. It uses simple tools such as a piston and a screw extruder to produce high pressure, driven by hand or by engine. A single screw extruder has one screw rotating inside the barrel and materials simultaneously flow from the feed to the die zone. The highest oil yield can be obtained by a well-designed oil press as well as finding the optimum conditions for all parameters involved during the ...

  2. Parameter Extraction for PSpice Models by means of an Automated Optimization Tool – An IGBT model Study Case

    DEFF Research Database (Denmark)

    Suárez, Carlos Gómez; Reigosa, Paula Diaz; Iannuzzo, Francesco

    2016-01-01

    An original tool for parameter extraction of PSpice models has been released, enabling a simple parameter identification. A physics-based IGBT model is used to demonstrate that the optimization tool is capable of generating a set of parameters which predicts the steady-state and switching behavio...

  3. Standardless quantification approach of TXRF analysis using fundamental parameter method

    International Nuclear Information System (INIS)

    Szaloki, I.; Taniguchi, K.

    2000-01-01

    New standardless evaluation procedure based on the fundamental parameter method (FPM) has been developed for TXRF analysis. The theoretical calculation describes the relationship between characteristic intensities and the geometrical parameters of the excitation, detection system and the specimen parameters: size, thickness, angle of the excitation beam to the surface and the optical properties of the specimen holder. Most of the TXRF methods apply empirical calibration, which requires the application of special preparation technique. However, the characteristic lines of the specimen holder (Si Kα,β) present information from the local excitation and geometrical conditions on the substrate surface. On the basis of the theoretically calculation of the substrate characteristic intensity the excitation beam flux can be approximated. Taking into consideration the elements are in the specimen material a system of non-linear equation can be given involving the unknown concentration values and the geometrical and detection parameters. In order to solve this mathematical problem PASCAL software was written, which calculates the sample composition and the average sample thickness by gradient algorithm. Therefore, this quantitative estimation of the specimen composition requires neither external nor internal standard sample. For verification of the theoretical calculation and the numerical procedure, several experiments were carried out using mixed standard solution containing elements of K, Sc, V, Mn, Co and Cu in 0.1 - 10 ppm concentration range. (author)

  4. Comparison of RNA extraction methods in Thai aromatic coconut water

    Directory of Open Access Journals (Sweden)

    Nopporn Jaroonchon

    2015-10-01

    Full Text Available Many researches have reported that nucleic acid in coconut water is in free form and at very low yields which makes it difficult to process in molecular studies. Our research attempted to compare two extraction methods to obtain a higher yield of total RNA in aromatic coconut water and monitor its change at various fruit stages. The first method used ethanol and sodium acetate as reagents; the second method used lithium chloride. We found that extraction using only lithium chloride gave a higher total RNA yield than the method using ethanol to precipitate nucleic acid. In addition, the total RNA from both methods could be used in amplification of betaine aldehyde dehydrogenase2 (Badh2 genes, which is involved in coconut aroma biosynthesis, and could be used to perform further study as we expected. From the molecular study, the nucleic acid found in coconut water increased with fruit age.

  5. DNA extraction method for PCR in mycorrhizal fungi.

    Science.gov (United States)

    Manian, S; Sreenivasaprasad, S; Mills, P R

    2001-10-01

    To develop a simple and rapid DNA extraction protocol for PCR in mycorrhizal fungi. The protocol combines the application of rapid freezing and boiling cycles and passage of the extracts through DNA purification columns. PCR amplifiable DNA was obtained from a number of endo- and ecto-mycorrhizal fungi using minute quantities of spores and mycelium, respectively. DNA extracted following the method, was used to successfully amplify regions of interest from high as well as low copy number genes. The amplicons were suitable for further downstream applications such as sequencing and PCR-RFLPs. The protocol described is simple, short and facilitates rapid isolation of PCR amplifiable genomic DNA from a large number of fungal isolates in a single day. The method requires only minute quantities of starting material and is suitable for mycorrhizal fungi as well as a range of other fungi.

  6. An efficient method for DNA extraction from Cladosporioid fungi.

    Science.gov (United States)

    Moslem, M A; Bahkali, A H; Abd-Elsalam, K A; Wit, P J G M

    2010-11-23

    We developed an efficient method for DNA extraction from Cladosporioid fungi, which are important fungal plant pathogens. The cell wall of Cladosporioid fungi is often melanized, which makes it difficult to extract DNA from their cells. In order to overcome this we grew these fungi for three days on agar plates and extracted DNA from mycelium mats after manual or electric homogenization. High-quality DNA was isolated, with an A(260)/A(280) ratio ranging between 1.6 and 2.0. Isolated genomic DNA was efficiently digested with restriction enzymes and produced distinct banding patterns on agarose gels for the different Cladosporium species. Clear DNA fragments from the isolated DNA were amplified by PCR using small and large subunit rDNA primers, demonstrating that this method provides DNA of sufficiently high quality for molecular analyses.

  7. Influence of Fermentation Methods on Neutral Detergent Fiber Degradation Parameters

    DEFF Research Database (Denmark)

    Bossen, D; Mertens, D R; Weisbjerg, M R

    2008-01-01

    The effect of 3 fermentation methods, in situ (IS) in 4 lactating cows (average pH of 5.8), in vitro (IVn) with media pH of 6.8, or in vitro (IVa) with media pH adjusted to 6.0 using citric acid, on fiber degradation parameters was studied using feeds ground to different particle sizes. Corn silage...

  8. An optimization method for parameters in reactor nuclear physics

    International Nuclear Information System (INIS)

    Jachic, J.

    1982-01-01

    An optimization method for two basic problems of Reactor Physics was developed. The first is the optimization of a plutonium critical mass and the bruding ratio for fast reactors in function of the radial enrichment distribution of the fuel used as control parameter. The second is the maximization of the generation and the plutonium burnup by an optimization of power temporal distribution. (E.G.) [pt

  9. Calculation of radon concentration in water by toluene extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Masaaki [Tokyo Metropolitan Isotope Research Center (Japan)

    1997-02-01

    Noguchi method and Horiuchi method have been used as the calculation method of radon concentration in water. Both methods have two problems in the original, that is, the concentration calculated is changed by the extraction temperature depend on the incorrect solubility data and the concentration calculated are smaller than the correct values, because the radon calculation equation does not true to the gas-liquid equilibrium theory. However, the two problems are solved by improving the radon equation. I presented the Noguchi-Saito equation and the constant B of Horiuchi-Saito equation. The calculating results by the improved method showed about 10% of error. (S.Y.)

  10. Development of {sup 99m}Tc extraction-recovery by solvent extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Akihiro; Nishikata, Kaori; Izumo, Hironobu; Tsuchiya, Kunihiko; Ishihara, Masahiro [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Tanase, Masakazu; Fujisaki, Saburo; Shiina, Takayuki; Ohta, Akio; Takeuchi, Nobuhiro [Chiyoda Technol Corp., Tokyo (Japan)

    2012-03-15

    {sup 99m}Tc is used as a radiopharmaceutical in the medical field for the diagnosis, and manufactured from {sup 99}Mo, the parent nuclide. In this study, the solvent extraction with MEK was selected, and preliminary experiments were carried out using Re instead of {sup 99m}Tc. Two tests were carried out in the experiments; the one is the Re extraction test with MEK from Re-Mo solution, the other is the Re recovery test from the Re-MEK. As to the Re extraction test, and it was clear that the Re extraction yield was more than 90%. Two kinds of Re recovery tests, which are an evaporation method using the evaporator and an adsorption/elution method using the alumina column, were carried out. As to the evaporation method, the Re concentration in the collected solution increased more than 150 times. As to the adsorption/elution method, the Re concentration increased in the eluted solution more than 20 times. (author)

  11. Development of automatic extraction method of left ventricular contours on long axis view MR cine images

    International Nuclear Information System (INIS)

    Utsunomiya, Shinichi; Iijima, Naoto; Yamasaki, Kazunari; Fujita, Akinori

    1995-01-01

    In the MRI cardiac function analysis, left ventricular volume curves and diagnosis parameters are obtained by extracting the left ventricular cavities as regions of interest (ROI) from long axis view MR cine images. The ROI extractions had to be done by manual operations, because automatization of the extraction is difficult. A long axis view left ventricular contour consists of a cardiac wall part and an aortic valve part. The above mentioned difficulty is due to the decline of contrast on the cardiac wall part, and the disappearance of edge on the aortic valve part. In this paper, we report a new automatic extraction method for long axis view MR cine images, which needs only 3 manually indicated points on the 1st image to extract all the contours from the total sequence of images. At first, candidate points of a contour are detected by edge detection. Then, selecting the best matched combination of candidate points by Dynamic Programming, the cardiac wall part is automatically extracted. The aortic valve part is manually extracted for the 1st image by indicating both the end points, and is automatically extracted for the rest of the images, by utilizing the aortic valve motion characteristics throughout a cardiac cycle. (author)

  12. Interpolation decoding method with variable parameters for fractal image compression

    International Nuclear Information System (INIS)

    He Chuanjiang; Li Gaoping; Shen Xiaona

    2007-01-01

    The interpolation fractal decoding method, which is introduced by [He C, Yang SX, Huang X. Progressive decoding method for fractal image compression. IEE Proc Vis Image Signal Process 2004;3:207-13], involves generating progressively the decoded image by means of an interpolation iterative procedure with a constant parameter. It is well-known that the majority of image details are added at the first steps of iterations in the conventional fractal decoding; hence the constant parameter for the interpolation decoding method must be set as a smaller value in order to achieve a better progressive decoding. However, it needs to take an extremely large number of iterations to converge. It is thus reasonable for some applications to slow down the iterative process at the first stages of decoding and then to accelerate it afterwards (e.g., at some iteration as we need). To achieve the goal, this paper proposed an interpolation decoding scheme with variable (iteration-dependent) parameters and proved the convergence of the decoding process mathematically. Experimental results demonstrate that the proposed scheme has really achieved the above-mentioned goal

  13. [Identification of special quality eggs with NIR spectroscopy technology based on symbol entropy feature extraction method].

    Science.gov (United States)

    Zhao, Yong; Hong, Wen-Xue

    2011-11-01

    Fast, nondestructive and accurate identification of special quality eggs is an urgent problem. The present paper proposed a new feature extraction method based on symbol entropy to identify near infrared spectroscopy of special quality eggs. The authors selected normal eggs, free range eggs, selenium-enriched eggs and zinc-enriched eggs as research objects and measured the near-infrared diffuse reflectance spectra in the range of 12 000-4 000 cm(-1). Raw spectra were symbolically represented with aggregation approximation algorithm and symbolic entropy was extracted as feature vector. An error-correcting output codes multiclass support vector machine classifier was designed to identify the spectrum. Symbolic entropy feature is robust when parameter changed and the highest recognition rate reaches up to 100%. The results show that the identification method of special quality eggs using near-infrared is feasible and the symbol entropy can be used as a new feature extraction method of near-infrared spectra.

  14. An Improved Method for Extraction and Separation of Photosynthetic Pigments

    Science.gov (United States)

    Katayama, Nobuyasu; Kanaizuka, Yasuhiro; Sudarmi, Rini; Yokohama, Yasutsugu

    2003-01-01

    The method for extracting and separating hydrophobic photosynthetic pigments proposed by Katayama "et al." ("Japanese Journal of Phycology," 42, 71-77, 1994) has been improved to introduce it to student laboratories at the senior high school level. Silica gel powder was used for removing water from fresh materials prior to…

  15. Genomic DNA extraction method from pearl millet ( Pennisetum ...

    African Journals Online (AJOL)

    DNA extraction is difficult in a variety of plants because of the presence of metabolites that interfere with DNA isolation procedures and downstream applications such as DNA restriction, amplification, and cloning. Here we describe a modified procedure based on the hexadecyltrimethylammonium bromide (CTAB) method to ...

  16. Genomic DNA extraction method from Annona senegalensis Pers ...

    African Journals Online (AJOL)

    Extraction of DNA in many plants is difficult because of the presence of metabolites that interfere with DNA isolation procedures and downstream applications such as DNA restriction, replications, amplification, as well as cloning. Modified procedure based on the hexadecyltrimethyl ammoniumbromide (CTAB) method is ...

  17. 7 CFR 51.1179 - Method of juice extraction.

    Science.gov (United States)

    2010-01-01

    ... STANDARDS) United States Standards for Grades of Florida Oranges and Tangelos Standards for Internal Quality... 7 Agriculture 2 2010-01-01 2010-01-01 false Method of juice extraction. 51.1179 Section 51.1179 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards...

  18. EXTRACTION OF SPATIAL PARAMETERS FROM CLASSIFIED LIDAR DATA AND AERIAL PHOTOGRAPH FOR SOUND MODELING

    Directory of Open Access Journals (Sweden)

    S. Biswas

    2012-07-01

    Full Text Available Prediction of outdoor sound levels in 3D space is important for noise management, soundscaping etc. Sound levels at outdoor can be predicted using sound propagation models which need terrain parameters. The existing practices of incorporating terrain parameters into models are often limited due to inadequate data or inability to determine accurate sound transmission paths through a terrain. This leads to poor accuracy in modelling. LIDAR data and Aerial Photograph (or Satellite Images provide opportunity to incorporate high resolution data into sound models. To realize this, identification of building and other objects and their use for extraction of terrain parameters are fundamental. However, development of a suitable technique, to incorporate terrain parameters from classified LIDAR data and Aerial Photograph, for sound modelling is a challenge. Determination of terrain parameters along various transmission paths of sound from sound source to a receiver becomes very complex in an urban environment due to the presence of varied and complex urban features. This paper presents a technique to identify the principal paths through which sound transmits from source to receiver. Further, the identified principal paths are incorporated inside the sound model for sound prediction. Techniques based on plane cutting and line tracing are developed for determining principal paths and terrain parameters, which use various information, e.g., building corner and edges, triangulated ground, tree points and locations of source and receiver. The techniques developed are validated through a field experiment. Finally efficacy of the proposed technique is demonstrated by developing a noise map for a test site.

  19. Parameters Affecting the Extraction Process of Jatropha curcas Oil Using a Single Screw Extruder

    Directory of Open Access Journals (Sweden)

    Ali Nurrakhmad Siregar

    2015-07-01

    Full Text Available The most commonly used technique to separate oil and cake from J. curcas seeds is mechanical extraction. It uses simple tools such as a piston and a screw extruder to produce high pressure, driven by hand or by engine. A single screw extruder has one screw rotating inside the barrel and materials simultaneously flow from the feed to the die zone. The highest oil yield can be obtained by a well-designed oil press as well as finding the optimum conditions for all parameters involved during the extraction process. The influence of the parameters in a single screw extruder was studied using finite element analysis and computational fluid dynamics simulation with ANSYS POLYFLOW. The research focused on predicting the velocity, pressure and shear rate in the metering section that influenced the screw rotational speed and mass flow rate. The obtained results revealed that increasing the screw rotational speed will increase the pressure, velocity and shear rate. Meanwhile, increasing the mass flow rate results in decreasing the pressure while the velocity and shear rate remain constant.

  20. Dynamic systems models new methods of parameter and state estimation

    CERN Document Server

    2016-01-01

    This monograph is an exposition of a novel method for solving inverse problems, a method of parameter estimation for time series data collected from simulations of real experiments. These time series might be generated by measuring the dynamics of aircraft in flight, by the function of a hidden Markov model used in bioinformatics or speech recognition or when analyzing the dynamics of asset pricing provided by the nonlinear models of financial mathematics. Dynamic Systems Models demonstrates the use of algorithms based on polynomial approximation which have weaker requirements than already-popular iterative methods. Specifically, they do not require a first approximation of a root vector and they allow non-differentiable elements in the vector functions being approximated. The text covers all the points necessary for the understanding and use of polynomial approximation from the mathematical fundamentals, through algorithm development to the application of the method in, for instance, aeroplane flight dynamic...

  1. The effect of heracleum persicum (Golpar oil and alcoholic extracts on sperm parameters and chromatin quality in mice

    Directory of Open Access Journals (Sweden)

    Neda Taghizabet

    2016-05-01

    Full Text Available Background: Evaluating the significance and the effects of plant-derived drugs on laboratory animal’s fertility was recognized. There was antioxidant activity reported from Heracleum persicum (Golpar. Objective: Current study aims to study the antioxidant effect of Golpar extracts on sperm parameters and chromatin quality in mice. Materials and Methods: Eighteen adult male mice were divided to 3 groups (10 wk old, 35 gr weight: group1 received hydro alcoholic extract (1000 mg/kg, ip, group 2 received oil extract (200 mg/kg, ip and group 3 serving as the sham control group that received sterile water. Finally, left cauda epididymis of each animal was dissected and sperm analysis was done accordingly. To asses sperm chromatin and DNA quality, we used aniline blue (AB, toluidine blue (TB, chromomycin A3 (CMA3 and acridine orange (AO staining. Results: Progressive and non-progressive sperm motility were significantly increased in group 1 in comparison with group 3 (p=0.032. There was an increasing trend in progressive sperm motility and decreasing trend in non-progressive sperm motility in group 2 in comparison with group 3, but the differences were not significant (p=0.221 and p=0.144, respectively. According to the sperm chromatin quality, the results of TB and AO tests revealed significant differences (p=0.004, p=0.000, respectively between those groups and showed that the extracts of Golpar cause DNA damage, but no differences can be observed between them in AB and CMA3 staining (p>0.05. Conclusion: The results showed that Heracleum persicum extracts may improve sperm motility. Also, it has harmful effects on sperm chromatin condensation and DNA integrity in mice

  2. Extraction of uranium from simulated ore by the supercritical carbon dioxide fluid extraction method with nitric acid-TBP complex

    International Nuclear Information System (INIS)

    Dung, Le Thi Kim; Imai, Tomoki; Tomioka, Osamu; Nakashima, Mikio; Takahashi, Kuniaki; Meguro, Yoshihiro

    2006-01-01

    The supercritical fluid extraction (SFE) method using CO 2 as a medium with an extractant of HNO 3 -tri-n-butyl phosphate (TBP) complex was applied to extract uranium from several uranyl phosphate compounds and simulated uranium ores. An extraction method consisting of a static extraction process and a dynamic one was established, and the effects of the experimental conditions, such as pressure, temperature, and extraction time, on the extraction of uranium were ascertained. It was found that uranium could be efficiently extracted from both the uranyl phosphates and simulated ores by the SFE method using CO 2 . It was thus demonstrated that the SFE method using CO 2 is useful as a pretreatment method for the analysis of uranium in ores. (author)

  3. An Aggregated Method for Determining Railway Defects and Obstacle Parameters

    Science.gov (United States)

    Loktev, Daniil; Loktev, Alexey; Stepanov, Roman; Pevzner, Viktor; Alenov, Kanat

    2018-03-01

    The method of combining algorithms of image blur analysis and stereo vision to determine the distance to objects (including external defects of railway tracks) and the speed of moving objects-obstacles is proposed. To estimate the deviation of the distance depending on the blur a statistical approach, logarithmic, exponential and linear standard functions are used. The statistical approach includes a method of estimating least squares and the method of least modules. The accuracy of determining the distance to the object, its speed and direction of movement is obtained. The paper develops a method of determining distances to objects by analyzing a series of images and assessment of depth using defocusing using its aggregation with stereoscopic vision. This method is based on a physical effect of dependence on the determined distance to the object on the obtained image from the focal length or aperture of the lens. In the calculation of the blur spot diameter it is assumed that blur occurs at the point equally in all directions. According to the proposed approach, it is possible to determine the distance to the studied object and its blur by analyzing a series of images obtained using the video detector with different settings. The article proposes and scientifically substantiates new and improved existing methods for detecting the parameters of static and moving objects of control, and also compares the results of the use of various methods and the results of experiments. It is shown that the aggregate method gives the best approximation to the real distances.

  4. A proposed method for fast determination of plasma parameters

    International Nuclear Information System (INIS)

    Braams, B.J.; Lackner, K.

    1984-09-01

    The method of function parametrization, developed and applied by H. Wind for fast data evaluation in high energy physics, is presented in the context of controlled fusion research. This method relies on statistical analysis of a data base of simulated experiments in order to obtain a functional representation for the intrinsic physical parameters of a system in terms of the values of the measurements. Some variations on Wind's original procedure are suggested. A specific application for tokamak experiments would be the determination of certain global parameters of the plasma, characterizing the current profile, shape of the cross-section, plasma pressure, and the internal inductance. The relevant measurements for this application include values of the poloidal field and flux external to the plasma, and a diamagnetic measurement. These may be combined with other diagnostics, such as electron-cyclotron emission and laser interferometry, in order to obtain also density and temperature profiles. There appears to be a capability for on-line determination of basic physical parameters, in a millisecond timescale on a minicomputer instead of in seconds on a large mainframe. (orig.)

  5. Deep Learning Methods for Underwater Target Feature Extraction and Recognition

    Directory of Open Access Journals (Sweden)

    Gang Hu

    2018-01-01

    Full Text Available The classification and recognition technology of underwater acoustic signal were always an important research content in the field of underwater acoustic signal processing. Currently, wavelet transform, Hilbert-Huang transform, and Mel frequency cepstral coefficients are used as a method of underwater acoustic signal feature extraction. In this paper, a method for feature extraction and identification of underwater noise data based on CNN and ELM is proposed. An automatic feature extraction method of underwater acoustic signals is proposed using depth convolution network. An underwater target recognition classifier is based on extreme learning machine. Although convolution neural networks can execute both feature extraction and classification, their function mainly relies on a full connection layer, which is trained by gradient descent-based; the generalization ability is limited and suboptimal, so an extreme learning machine (ELM was used in classification stage. Firstly, CNN learns deep and robust features, followed by the removing of the fully connected layers. Then ELM fed with the CNN features is used as the classifier to conduct an excellent classification. Experiments on the actual data set of civil ships obtained 93.04% recognition rate; compared to the traditional Mel frequency cepstral coefficients and Hilbert-Huang feature, recognition rate greatly improved.

  6. Effects of Artemisia lanata Extract on Reproductive Parameters of Female Rats

    Directory of Open Access Journals (Sweden)

    Ainehchi Nava

    2014-04-01

    Full Text Available Objective: Until date, there is no report on safety of Artemisia lanata. This study aimed to determine the possible undesirable effects of A. lanata on reproduction of female rats. Materials and Methods: The pregnant rats were treated (i.p. with vehicle or 200 and 400mg/kg of A. lanata hydroalcoholic extract from the 2-8 day of pregnancy. Then, number and weight of neonates, duration of pregnancy, and percent of dead fetuses were determined. Furthermore, cytotoxicity of this plant was tested using fibroblast (L929 and Chinese hamster ovary (Cho cell lines. Results: The A. lanata had no significant effect on duration of pregnancy, average number of neonates, and weight of neonates. However, administration of 200 and 400 mg/kg of the extract led to 30 and 44% abortion in animals, respectively. The extract at concentrations ≥ 200 μg/ml significantly (P < 0.001 inhibited the proliferation of L929 fibroblast cells. Regarding the Cho cells, the extract induced toxicity only at concentration of 800 μg/ml (P < 0.010. Conclusion: Our results showed that continuous consumption of A. lanata in pregnancy may increase the risk of abortion and also may have toxic effect on some cells.

  7. Analytical methods and problems for the diamides type of extractants

    International Nuclear Information System (INIS)

    Cuillerdier, C.; Nigond, L.; Musikas, C.; Vitart, H.; Hoel, P.

    1989-01-01

    Diamides of carboxylic acids and especially malonamides are able to extract alpha emitters (including trivalent ions such as Am and Cm) contained in the wastes solutions of the nuclear industry. As they are completely incinerable and easy to purify, they could be an alternative to the mixture CMPO-TBP which is used in the TRUEX process. A large oxyalkyl radical enhances the distribution coefficients of americium in nitric acid sufficiently to permit the decontamination of wastes solutions in a classical mixers-settlers battery. Now researches are pursued with the aim of optimizing the formula of extractant, the influence of the structure of the extractant on its basicity and stability under radiolysis and hydrolysis is investigated. Analytical methods (potentiometry and NMR of C 13 ) have been developed for solvent titration and to evaluate the percentage of degradation and to identify some of the degradation products

  8. Analysis of Feature Extraction Methods for Speaker Dependent Speech Recognition

    Directory of Open Access Journals (Sweden)

    Gurpreet Kaur

    2017-02-01

    Full Text Available Speech recognition is about what is being said, irrespective of who is saying. Speech recognition is a growing field. Major progress is taking place on the technology of automatic speech recognition (ASR. Still, there are lots of barriers in this field in terms of recognition rate, background noise, speaker variability, speaking rate, accent etc. Speech recognition rate mainly depends on the selection of features and feature extraction methods. This paper outlines the feature extraction techniques for speaker dependent speech recognition for isolated words. A brief survey of different feature extraction techniques like Mel-Frequency Cepstral Coefficients (MFCC, Linear Predictive Coding Coefficients (LPCC, Perceptual Linear Prediction (PLP, Relative Spectra Perceptual linear Predictive (RASTA-PLP analysis are presented and evaluation is done. Speech recognition has various applications from daily use to commercial use. We have made a speaker dependent system and this system can be useful in many areas like controlling a patient vehicle using simple commands.

  9. The evaluation of some thermodynamic parameters by RIA method

    International Nuclear Information System (INIS)

    Dorobantu, I. I.; Cucu Delia-Irina

    2001-01-01

    The present paper evaluates some of thermodynamic parameters by using RIA (radioimmunoassay) method. The RIA systems studied were: 1) antiprogesterone antibody-progesterone- 3 H; 2) antiprogesterone antibody-progesterone- 125 I. The antigen (progesterone) was labelled with 3 H, in the first case, and 125 I in the second one (progesterone- 125 I was progesterone-6-S-CH 2 -CO-histamine- 125 I). RIA reactions were developed at two temperatures: 277 K and 296 K. Samples of antiprogesterone antibodies and labelled progesterone were incubated with different amounts of unlabeled progesterone. The immune complex was precipitated after reaching the chemical equilibrium and its radioactivity measured at γ-counter. By the radioactive measurements, the affinity constants (K S ) were estimated. The values of the affinity constants were used to estimate the thermodynamic parameters of the systems, such as: enthalpy (ΔH), Gibbs energy (ΔG) and entropy (ΔS). (authors)

  10. Parameters of explosives detection through tagged neutron method

    Energy Technology Data Exchange (ETDEWEB)

    Bagdasaryan, Kh.E.; Batyaev, V.F.; Belichenko, S.G., E-mail: consul757@mail.ru; Bestaev, R.R.; Gavryuchenkov, A.V.; Karetnikov, M.D.

    2015-06-01

    The potentialities of tagged neutron method (TNM) for explosives detection are examined on the basis of an idealized geometrical model. The model includes ING-27 14 MeV neutron generator with a built-in α-detector, a LYSO γ-detector and samples of material to be identified of approximately 0.3 kg each: explosives imitators (trinitrotoluene - TNT, tetryl, RDX and ammonium nitrate), legal materials (sugar, water, silk and polyethylene). The samples were unshielded or shielded by a paper layer of various thicknesses. The experimental data were interpreted by numerical simulation using a Poisson distribution of signals with the statistical parameters defined experimentally. The detection parameters were obtained by a pattern classification theory and a Bayes classifier.

  11. Activation method for measuring the neutron spectra parameters. Computer software

    International Nuclear Information System (INIS)

    Efimov, B.V.; Ionov, V.S.; Konyaev, S.I.; Marin, S.V.

    2005-01-01

    The description of mathematical statement of a task for definition the spectral characteristics of neutron fields with use developed in RRC KI unified activation detectors (UKD) is resulted. The method of processing of results offered by authors activation measurements and calculation of the parameters used for an estimation of the neutron spectra characteristics is discussed. Features of processing of the experimental data received at measurements of activation with using UKD are considered. Activation detectors UKD contain a little bit specially the picked up isotopes giving at irradiation peaks scale of activity in the common spectrum scale of activity. Computing processing of results of the measurements is applied on definition of spectrum parameters for nuclear reactor installations with thermal and close to such power spectrum of neutrons. The example of the data processing, the measurements received at carrying out at RRC KI research reactor F-1 is resulted [ru

  12. Isolation and Identification of Volatile Components in Tempe by Simultaneous Distillation-Extraction Method by Modified Extraction Method

    Directory of Open Access Journals (Sweden)

    Syahrial Syahrial

    2010-06-01

    Full Text Available An isolation and identification of volatile components in temps for 2, 5 and 8 days fermentation by simultaneous distillation-extraction method was carried out. Simultaneous distillation-extraction apparatus was modified by Muchalal from the basic Likens-Nickerson's design. Steam distillation and benzena as an extraction solvent was used in this system. The isolation was continuously carried out for 3 hours which maximum water temperature In the Liebig condenser was 8 °C. The extract was concentrated by freeze concentration method, and the volatile components were analyzed and identified by combined gas chromatography-mass spectrophotometry (GC-MS. The Muchalal's simultaneous distillation extraction apparatus have some disadvantage in cold finger condenser, and it's extractor did not have condenser. At least 47, 13 and 5 volatile components were found in 2, 5 and 8 days fermentation, respectively. The volatile components in the 2 days fermentation were nonalal, ɑ-pinene, 2,4-decadienal, 5-phenyldecane, 5-phenylundecane, 4-phenylundecane, 5-phenyldodecane, 4-phenyldodecane, 3-phenyldodecane, 2-phenyldodecane, 5-phenyltridecane, and caryophyllene; in the 5 days fermentation were nonalal, caryophyllene, 4-phenylundecane, 5-phenyldodecane, 4-phenyldodecane, 3-phenyldodecane, 2-phenyldodecane; and in the 8 days fermentation were ethenyl butanoic, 2-methy1-3-(methylethenylciclohexyl etanoic and 3,7-dimethyl-5-octenyl etanoic.

  13. Lipid Extraction Methods from Microalgae: A Comprehensive Review

    Energy Technology Data Exchange (ETDEWEB)

    Ranjith Kumar, Ramanathan [Department of Plant Biology and Plant Biotechnology, Shree Chandraprabhu Jain College, Chennai (India); Hanumantha Rao, Polur [Department of Microbiology, Madras Christian College, Chennai (India); Arumugam, Muthu, E-mail: arumugam@niist.res.in [Division of Biotechnology, CSIR – National Institute for Interdisciplinary Science and Technology (NIIST), Trivandrum (India)

    2015-01-08

    Energy security has become a serious global issue and a lot of research is being carried out to look for economically viable and environment-friendly alternatives. The only solution that appears to meet futuristic needs is the use of renewable energy. Although various forms of renewable energy are being currently used, the prospects of producing carbon-neutral biofuels from microalgae appear bright because of their unique features such as suitability of growing in open ponds required for production of a commodity product, high CO{sub 2}-sequestering capability, and ability to grow in wastewater/seawater/brackish water and high-lipid productivity. The major process constraint in microalgal biofuel technology is the cost-effective and efficient extraction of lipids. The objective of this article is to provide a comprehensive review on various methods of lipid extraction from microalgae available, to date, as well as to discuss their advantages and disadvantages. The article covers all areas of lipid extraction procedures including solvent extraction procedures, mechanical approaches, and solvent-free procedures apart from some of the latest extraction technologies. Further research is required in this area for successful implementation of this technology at the production scale.

  14. Lipid Extraction Methods from Microalgae: A Comprehensive Review

    International Nuclear Information System (INIS)

    Ranjith Kumar, Ramanathan; Hanumantha Rao, Polur; Arumugam, Muthu

    2015-01-01

    Energy security has become a serious global issue and a lot of research is being carried out to look for economically viable and environment-friendly alternatives. The only solution that appears to meet futuristic needs is the use of renewable energy. Although various forms of renewable energy are being currently used, the prospects of producing carbon-neutral biofuels from microalgae appear bright because of their unique features such as suitability of growing in open ponds required for production of a commodity product, high CO 2 -sequestering capability, and ability to grow in wastewater/seawater/brackish water and high-lipid productivity. The major process constraint in microalgal biofuel technology is the cost-effective and efficient extraction of lipids. The objective of this article is to provide a comprehensive review on various methods of lipid extraction from microalgae available, to date, as well as to discuss their advantages and disadvantages. The article covers all areas of lipid extraction procedures including solvent extraction procedures, mechanical approaches, and solvent-free procedures apart from some of the latest extraction technologies. Further research is required in this area for successful implementation of this technology at the production scale.

  15. Research On The Measure Method Of Oblique Pinhole Parameters

    Directory of Open Access Journals (Sweden)

    Ma Yu-Zhen

    2016-01-01

    Full Text Available There are many special advantages in measuring the diameter of blind and deep holes with a capacitive probe, there are still some challenges for the measurement of a oblique pinhole parameters because the measuring device is inconvenient to stretch into the oblique pinhole exactly. A five-dimensional measurement system was adopted in the paper which included a capacitive sensor probe and a three-coordinate measuring machine to accomplish the measurement for oblique pinholes. With the help of the three-dimensional coordinates measured from the pinhole axis, we put forward a comprehensive method of combining the projection method and the least squares method together for fitting spatial straight line to obtain the optimal equation of the spacial axis. Finally, a reliable and entire measurement system was set up.

  16. τ lifetime with the impact parameter difference method

    International Nuclear Information System (INIS)

    Andreazza, A.

    1995-01-01

    The impact parameter difference method for measuring the τ lifetime has been used since 1990 in the ALEPH and DELPHI collaborations at LEP. This paper is mainly devoted to the description of the method. The most recent preliminary results, τ τ =288.1±5.4(stat.)±1.2(syst.)fs obtained by the ALEPH collaboration on 1992 data and τ τ =292.8±5.0(stat.)±3.7(syst.)fs from the combined DELPHI analysis of 1992-93 data, are still statistically limited, therefore a global error on the τ lifetime of less than 1% per experiment should be attainable with this method at the end of LEP-1 running. ((orig.))

  17. Ultrasound assisted methods for enhanced extraction of phycobiliproteins from marine macro-algae, Gelidium pusillum (Rhodophyta).

    Science.gov (United States)

    Mittal, Rochak; Tavanandi, Hrishikesh A; Mantri, Vaibhav A; Raghavarao, K S M S

    2017-09-01

    Extraction of phycobiliproteins (R-phycoerythrin, R-PE and R-phycocyanin, R-PC) from macro-algae is difficult due to the presence of large polysaccharides (agar, cellulose etc.) present in the cell wall which offer major hindrance for cell disruption. The present study is aimed at developing most suitable methodology for the primary extraction of R-PE and R-PC from marine macro-algae, Gelidium pusillum(Stackhouse) Le Jolis. Such extraction of phycobiliproteins by using ultrasonication and other conventional methods such as maceration, maceration in presence of liquid nitrogen, homogenization, and freezing and thawing (alone and in combinations) is reported for the first time. Standardization of ultrasonication for different parameters such as ultrasonication amplitude (60, 90 and 120µm) and ultrasonication time (1, 2, 4, 6, 8 and 10mins) at different temperatures (30, 35 and 40°C) was carried out. Kinetic parameters were estimated for extraction of phycobiliproteins by ultrasonication based on second order mass transfer kinetics. Based on calorimetric measurements, power, ultrasound intensity and acoustic power density were estimated to be 41.97W, 14.81W/cm 2 and 0.419W/cm 3 , respectively. Synergistic effect of ultrasonication was observed when employed in combination with other conventional primary extraction methods. Homogenization in combination with ultrasonication resulted in an enhancement in efficiency by 9.3% over homogenization alone. Similarly, maceration in combination with ultrasonication resulted in an enhancement in efficiency by 31% over maceration alone. Among all the methods employed, maceration in combination with ultrasonication resulted in the highest extraction efficiency of 77 and 93% for R-PE and R-PC, respectively followed by homogenization in combination with ultrasonication (69.6% for R-PE and 74.1% for R-PC). HPLC analysis was carried out in order to ensure that R-PE was present in the extract and remained intact even after processing

  18. Application of Muskingum routing method with variable parameters in ungauged basin

    Directory of Open Access Journals (Sweden)

    Xiao-meng Song

    2011-03-01

    Full Text Available This paper describes a flood routing method applied in an ungauged basin, utilizing the Muskingum model with variable parameters of wave travel time K and weight coefficient of discharge x based on the physical characteristics of the river reach and flood, including the reach slope, length, width, and flood discharge. Three formulas for estimating parameters of wide rectangular, triangular, and parabolic cross sections are proposed. The influence of the flood on channel flow routing parameters is taken into account. The HEC-HMS hydrological model and the geospatial hydrologic analysis module HEC-GeoHMS were used to extract channel or watershed characteristics and to divide sub-basins. In addition, the initial and constant-rate method, user synthetic unit hydrograph method, and exponential recession method were used to estimate runoff volumes, the direct runoff hydrograph, and the baseflow hydrograph, respectively. The Muskingum model with variable parameters was then applied in the Louzigou Basin in Henan Province of China, and of the results, the percentages of flood events with a relative error of peak discharge less than 20% and runoff volume less than 10% are both 100%. They also show that the percentages of flood events with coefficients of determination greater than 0.8 are 83.33%, 91.67%, and 87.5%, respectively, for rectangular, triangular, and parabolic cross sections in 24 flood events. Therefore, this method is applicable to ungauged basins.

  19. About increasing informativity of diagnostic system of asynchronous electric motor by extracting additional information from values of consumed current parameter

    Science.gov (United States)

    Zhukovskiy, Y.; Korolev, N.; Koteleva, N.

    2018-05-01

    This article is devoted to expanding the possibilities of assessing the technical state of the current consumption of asynchronous electric drives, as well as increasing the information capacity of diagnostic methods, in conditions of limited access to equipment and incompleteness of information. The method of spectral analysis of the electric drive current can be supplemented by an analysis of the components of the current of the Park's vector. The research of the hodograph evolution in the moment of appearance and development of defects was carried out using the example of current asymmetry in the phases of an induction motor. The result of the study is the new diagnostic parameters of the asynchronous electric drive. During the research, it was proved that the proposed diagnostic parameters allow determining the type and level of the defect. At the same time, there is no need to stop the equipment and taky it out of service for repair. Modern digital control and monitoring systems can use the proposed parameters based on the stator current of an electrical machine to improve the accuracy and reliability of obtaining diagnostic patterns and predicting their changes in order to improve the equipment maintenance systems. This approach can also be used in systems and objects where there are significant parasitic vibrations and unsteady loads. The extraction of useful information can be carried out in electric drive systems in the structure of which there is a power electric converter.

  20. Computation of rectangular source integral by rational parameter polynomial method

    International Nuclear Information System (INIS)

    Prabha, Hem

    2001-01-01

    Hubbell et al. (J. Res. Nat Bureau Standards 64C, (1960) 121) have obtained a series expansion for the calculation of the radiation field generated by a plane isotropic rectangular source (plaque), in which leading term is the integral H(a,b). In this paper another integral I(a,b), which is related with the integral H(a,b) has been solved by the rational parameter polynomial method. From I(a,b), we compute H(a,b). Using this method the integral I(a,b) is expressed in the form of a polynomial of a rational parameter. Generally, a function f (x) is expressed in terms of x. In this method this is expressed in terms of x/(1+x). In this way, the accuracy of the expression is good over a wide range of x as compared to the earlier approach. The results for I(a,b) and H(a,b) are given for a sixth degree polynomial and are found to be in good agreement with the results obtained by numerically integrating the integral. Accuracy could be increased either by increasing the degree of the polynomial or by dividing the range of integration. The results of H(a,b) and I(a,b) are given for values of b and a up to 2.0 and 20.0, respectively

  1. Methods of calculating engineering parameters for gas separations

    Science.gov (United States)

    Lawson, D. D.

    1980-01-01

    A group additivity method has been generated which makes it possible to estimate, from the structural formulas alone, the energy of vaporization and the molar volume at 25 C of many nonpolar organic liquids. From these two parameters and appropriate thermodynamic relationships it is then possible to predict the vapor pressure of the liquid phase and the solubility of various gases in nonpolar organic liquids. The data are then used to evaluate organic and some inorganic liquids for use in gas separation stages or as heat exchange fluids in prospective thermochemical cycles for hydrogen production.

  2. Evaluation of in vitro antioxidant potential of different polarities stem crude extracts by different extraction methods of Adenium obesum

    Directory of Open Access Journals (Sweden)

    Mohammad Amzad Hossain

    2014-09-01

    Full Text Available Objective: To select best extraction method for the isolated antioxidant compounds from the stems of Adenium obesum. Methods: Two methods used for the extraction are Soxhlet and maceration methods. Methanol solvent was used for both extraction method. The methanol crude extract was defatted with water and extracted successively with hexane, chloroform, ethyl acetate and butanol solvents. The antioxidant potential for all crude extracts were determined by using 1, 1-diphenyl-2- picrylhydrazyl method. Results: The percentage of extraction yield by Soxhlet method is higher compared to maceration method. The antioxidant potential for methanol and its derived fractions by Soxhlet extractor method was highest in ethyl acetate and lowest in hexane crude extracts and found in the order of ethyl acetate>butanol>water>chloroform>methanol>hexane. However, the antioxidant potential for methanol and its derived fractions by maceration method was highest in butanol and lowest in hexane followed in the order of butanol>methanol>chloroform>water>ethyl acetate>hexane. Conclusions: The results showed that isolate antioxidant compounds effected on the extraction method and condition of extraction.

  3. A comprehensive benchmark of kernel methods to extract protein-protein interactions from literature.

    Directory of Open Access Journals (Sweden)

    Domonkos Tikk

    Full Text Available The most important way of conveying new findings in biomedical research is scientific publication. Extraction of protein-protein interactions (PPIs reported in scientific publications is one of the core topics of text mining in the life sciences. Recently, a new class of such methods has been proposed - convolution kernels that identify PPIs using deep parses of sentences. However, comparing published results of different PPI extraction methods is impossible due to the use of different evaluation corpora, different evaluation metrics, different tuning procedures, etc. In this paper, we study whether the reported performance metrics are robust across different corpora and learning settings and whether the use of deep parsing actually leads to an increase in extraction quality. Our ultimate goal is to identify the one method that performs best in real-life scenarios, where information extraction is performed on unseen text and not on specifically prepared evaluation data. We performed a comprehensive benchmarking of nine different methods for PPI extraction that use convolution kernels on rich linguistic information. Methods were evaluated on five different public corpora using cross-validation, cross-learning, and cross-corpus evaluation. Our study confirms that kernels using dependency trees generally outperform kernels based on syntax trees. However, our study also shows that only the best kernel methods can compete with a simple rule-based approach when the evaluation prevents information leakage between training and test corpora. Our results further reveal that the F-score of many approaches drops significantly if no corpus-specific parameter optimization is applied and that methods reaching a good AUC score often perform much worse in terms of F-score. We conclude that for most kernels no sensible estimation of PPI extraction performance on new text is possible, given the current heterogeneity in evaluation data. Nevertheless, our study

  4. SAR Data Fusion Imaging Method Oriented to Target Feature Extraction

    Directory of Open Access Journals (Sweden)

    Yang Wei

    2015-02-01

    Full Text Available To deal with the difficulty for target outlines extracting precisely due to neglect of target scattering characteristic variation during the processing of high-resolution space-borne SAR data, a novel fusion imaging method is proposed oriented to target feature extraction. Firstly, several important aspects that affect target feature extraction and SAR image quality are analyzed, including curved orbit, stop-and-go approximation, atmospheric delay, and high-order residual phase error. Furthermore, the corresponding compensation methods are addressed as well. Based on the analysis, the mathematical model of SAR echo combined with target space-time spectrum is established for explaining the space-time-frequency change rule of target scattering characteristic. Moreover, a fusion imaging strategy and method under high-resolution and ultra-large observation angle range conditions are put forward to improve SAR quality by fusion processing in range-doppler and image domain. Finally, simulations based on typical military targets are used to verify the effectiveness of the fusion imaging method.

  5. The investigation of parameters affecting boron removal by electrocoagulation method

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, A. Erdem [Department of Environmental Engineering, Atatuerk University, Faculty of Engineering, Erzurum (Turkey)]. E-mail: aerdemy@atauni.edu.tr; Boncukcuoglu, Recep [Department of Environmental Engineering, Atatuerk University, Faculty of Engineering, Erzurum (Turkey); Kocakerim, M. Muhtar [Department of Chemical Engineering, 25240, Atatuerk University, Faculty of Engineering Erzurum (Turkey); Keskinler, Buelent [Department of Environmental Engineering, Gebze Institute of Technology, Gebze/Kocaeli 41400 (Turkey)

    2005-10-17

    Boron removal from wastewaters by electrocoagulation using aluminum electrode material was investigated in this paper. Several working parameters, such as pH, current density, boron concentration and type and concentration of supporting electrolyte were studied in an attempt to achieve a higher removal capacity. The experiments were carried out by keeping the pH of solution constant and optimum pH of solution was determined 8.0 for the aluminum electrode. Although energy consumption increased with decreasing boron concentration, which conductivity of these solutions were low, boron removal efficiency was higher at 100 mg/L than that of 1000 mg/L. Current density was an important parameter affecting removal efficiency. Boron removal efficiency and energy consumption increased with increasing current density from 1.2 to 6.0 mA/cm{sup 2}. The types of different supporting electrolyte were experimented in order to investigate to this parameter effect on boron removal. The highest boron removal efficiency, 97%, was found by CaCl{sub 2}. Added CaCl{sub 2} increased more the conductivity of solution according to other supporting electrolytes, but decreased energy consumption. The results showed to have a high effectiveness of the electrocoagulation method in removing boron from aqueous solutions.

  6. The investigation of parameters affecting boron removal by electrocoagulation method

    International Nuclear Information System (INIS)

    Yilmaz, A. Erdem; Boncukcuoglu, Recep; Kocakerim, M. Muhtar; Keskinler, Buelent

    2005-01-01

    Boron removal from wastewaters by electrocoagulation using aluminum electrode material was investigated in this paper. Several working parameters, such as pH, current density, boron concentration and type and concentration of supporting electrolyte were studied in an attempt to achieve a higher removal capacity. The experiments were carried out by keeping the pH of solution constant and optimum pH of solution was determined 8.0 for the aluminum electrode. Although energy consumption increased with decreasing boron concentration, which conductivity of these solutions were low, boron removal efficiency was higher at 100 mg/L than that of 1000 mg/L. Current density was an important parameter affecting removal efficiency. Boron removal efficiency and energy consumption increased with increasing current density from 1.2 to 6.0 mA/cm 2 . The types of different supporting electrolyte were experimented in order to investigate to this parameter effect on boron removal. The highest boron removal efficiency, 97%, was found by CaCl 2 . Added CaCl 2 increased more the conductivity of solution according to other supporting electrolytes, but decreased energy consumption. The results showed to have a high effectiveness of the electrocoagulation method in removing boron from aqueous solutions

  7. Express method for contactless measurement of parameters of thermoelectric materials

    Directory of Open Access Journals (Sweden)

    Ashcheulov A. A.

    2015-08-01

    Full Text Available The paper presents an original method for contactless express measurement of parameters of thermoelectric materials. The presence of a combination of AC and DC magnetic fields in the gap of the oscillating circuit, where the monitored sample of the thermoelectric material is located, leads — due to Ampere force — to delamination of geometric regions of the occurrence of half-cycles of Foucault current. This in turn causes the appearance of additional heat losses in the oscillating circuit caused by Peltier effect. Computer modeling of these processes with the use of the software package ComsolFenlab 3.3 allowed determining the nature and magnitude of the electric currents in oscillating circuit, the range of operating frequencies, and the ratio of amplitudes of the variable and fixed components of the magnetic field. These components eventually cause a certain temperature difference along the controlled sample, which difference is proportional to the thermoelectric figure of merit Z of the material. The basic expressions are obtained for determining the value of the Seebeck coefficient a, thermal conductivity ?, electrical conductivity ? and thermoelectric figure of merit Z. A description is given to the design of the device for contactless express measurement of parameters of thermoelectric materials based on Bi—Te—Se—Sb solid solutions. Its distinctive feature is the ability to determine the symmetric and asymmetric components of the electric conductivity of the material values. The actual error in parameter measurement in this case is 2%.

  8. Decrease in spermatic parameters of mice treated with hydroalcoholic extract Tropaeolum tuberosum “mashua”

    Directory of Open Access Journals (Sweden)

    Jonathan H. Vásquez

    2012-10-01

    Full Text Available In this work, we provided a Tropaeolum tuberosum hydroalcoholic extract to male mice (780 mg kg-1 for 7, 14 and 21 days treatment, there was no significant difference in body weight gain, testes, epididymides and prostate weight (p> 0.05, nevertheless progressive motility decreased and immobile sperm count increased significantly after 21 days treatment (p <0.05. The sperm count in the epididymis cauda decreased in the 3 three assessments, concentration on 21 days treatment was significantly lower than those of 7 and 14 days treatments (p <0.05. Our results suggest, that T. tuberosum has a direct action on the male reproductive system decreasing spermatic parameters without exerting toxic effects on mice.

  9. Exact extraction method for road rutting laser lines

    Science.gov (United States)

    Hong, Zhiming

    2018-02-01

    This paper analyzes the importance of asphalt pavement rutting detection in pavement maintenance and pavement administration in today's society, the shortcomings of the existing rutting detection methods are presented and a new rutting line-laser extraction method based on peak intensity characteristic and peak continuity is proposed. The intensity of peak characteristic is enhanced by a designed transverse mean filter, and an intensity map of peak characteristic based on peak intensity calculation for the whole road image is obtained to determine the seed point of the rutting laser line. Regarding the seed point as the starting point, the light-points of a rutting line-laser are extracted based on the features of peak continuity, which providing exact basic data for subsequent calculation of pavement rutting depths.

  10. Integrated Phoneme Subspace Method for Speech Feature Extraction

    Directory of Open Access Journals (Sweden)

    Park Hyunsin

    2009-01-01

    Full Text Available Speech feature extraction has been a key focus in robust speech recognition research. In this work, we discuss data-driven linear feature transformations applied to feature vectors in the logarithmic mel-frequency filter bank domain. Transformations are based on principal component analysis (PCA, independent component analysis (ICA, and linear discriminant analysis (LDA. Furthermore, this paper introduces a new feature extraction technique that collects the correlation information among phoneme subspaces and reconstructs feature space for representing phonemic information efficiently. The proposed speech feature vector is generated by projecting an observed vector onto an integrated phoneme subspace (IPS based on PCA or ICA. The performance of the new feature was evaluated for isolated word speech recognition. The proposed method provided higher recognition accuracy than conventional methods in clean and reverberant environments.

  11. Optimization and Comparison of Ultrasound-Assisted Extraction of Estragole from Tarragon Leaves with Hydro-Distillation Method

    Directory of Open Access Journals (Sweden)

    Mohammad Bagher Gholivand

    2014-12-01

    Full Text Available A comparative study of ultrasound-assisted extraction (UAE and hydro-distillation was performed for fast extraction of estragole from tarragon (Artemisia dracunculus L. dried leaves. Several influential parameters of the UAE procedure in the extraction of estragole (type of solvent, extraction cycles, solvent to material ratio, irradiation time and particle size were investigated and optimized. It was found that UAE offers a more rapid extraction of estragole than hydrodistillation. The optimum parameters were solvent to material ratio of 8:1 v/m, 96% (w/w ethanol in water as extraction solvent, particle size of 1.18 mm, irradiation time of 5 min, output power of 63 W, 9 pulses, and ultrasonic frequency of 20 kHz. The recovery of estragole by UAE under optimal conditions was 44.4% based on dry extract. The benefit of ultrasound was to decrease the extraction time (5 min relative to the classical hydrodistillation method (3 h. The experimental results also indicated that ultrasound-assisted extraction is a simple, rapid and effective method for extraction of the volatile oil components of tarragon.

  12. A method for external measurement of toroidal equilibrium parameters

    International Nuclear Information System (INIS)

    Brunsell, P.; Hellblom, G.; Brynolf, J.

    1992-01-01

    A method has been developed for determining from external magnetic field measurements the horizontal shift, the vertical shift and the poloidal field asymmetry parameter (Λ) of a toroidal plasma in force equilibrium. The magnetic measurements consist of two toroidal differential flux loops, giving the average vertical magnetic field and the average radial magnetic field respectively, together with cosine-coils for obtaining the m=1 cosine harmonic of the external poloidal magnetic field component. The method is used to analyse the evolution of the toroidal equilibrium during reversed-field pinch discharges in the Extrap T1-U device. We find that good equilibrium control is needed for long plasma pulses. For non-optimized externally applied vertical fields, the diagnostic clearly shows a horizontal drift motion of the pinch resulting in earlier discharge termination. (au)

  13. Exploring the Effects of Pulsed Electric Field Processing Parameters on Polyacetylene Extraction from Carrot Slices

    Directory of Open Access Journals (Sweden)

    Ingrid Aguiló-Aguayo

    2015-03-01

    Full Text Available The effects of various pulsed electric field (PEF parameters on the extraction of polyacetylenes from carrot slices were investigated. Optimised conditions with regard to electric field strength (1–4 kV/cm, number of pulses (100–1500, pulse frequency (10–200 Hz and pulse width (10–30 μs were identified using response surface methodology (RSM to maximise the extraction of falcarinol (FaOH, falcarindiol (FaDOH and falcarindiol-3-acetate (FaDOAc from carrot slices. Data obtained from RSM and experiments fitted significantly (p < 0.0001 the proposed second-order response functions with high regression coefficients (R2 ranging from 0.82 to 0.75. Maximal FaOH (188%, FaDOH (164.9% and FaDOAc (166.8% levels relative to untreated samples were obtained from carrot slices after applying PEF treatments at 4 kV/cm with 100 number of pulses of 10 μs at 10 Hz. The predicted values from the developed quadratic polynomial equation were in close agreement with the actual experimental values with low average mean deviations (E% ranging from 0.68% to 3.58%.

  14. Extracting a mix parameter from 2D radiography of variable density flow

    Science.gov (United States)

    Kurien, Susan; Doss, Forrest; Livescu, Daniel

    2017-11-01

    A methodology is presented for extracting quantities related to the statistical description of the mixing state from the 2D radiographic image of a flow. X-ray attenuation through a target flow is given by the Beer-Lambert law which exponentially damps the incident beam intensity by a factor proportional to the density, opacity and thickness of the target. By making reasonable assumptions for the mean density, opacity and effective thickness of the target flow, we estimate the contribution of density fluctuations to the attenuation. The fluctuations thus inferred may be used to form the correlation of density and specific-volume, averaged across the thickness of the flow in the direction of the beam. This correlation function, denoted by b in RANS modeling, quantifies turbulent mixing in variable density flows. The scheme is tested using DNS data computed for variable-density buoyancy-driven mixing. We quantify the deficits in the extracted value of b due to target thickness, Atwood number, and modeled noise in the incident beam. This analysis corroborates the proposed scheme to infer the mix parameter from thin targets at moderate to low Atwood numbers. The scheme is then applied to an image of counter-shear flow obtained from experiments at the National Ignition Facility. US Department of Energy.

  15. EFFECTS OF EXTRACTION METHODS ON PHYSICO-CHEMICAL ...

    African Journals Online (AJOL)

    The relative density value ranged from 0.9 to 0.92 at 29°C (room temperature). Both oil samples were in liquid state at room temperature and boiling points varied from 94°C-to 98°C for solvent extracted oil and hydraulic press oil respectively. The results showed thatJhe method ofextraction imposed significant changes on ...

  16. Effects of Feature Extraction and Classification Methods on Cyberbully Detection

    OpenAIRE

    ÖZEL, Selma Ayşe; SARAÇ, Esra

    2016-01-01

    Cyberbullying is defined as an aggressive, intentional action against a defenseless person by using the Internet, or other electronic contents. Researchers have found that many of the bullying cases have tragically ended in suicides; hence automatic detection of cyberbullying has become important. In this study we show the effects of feature extraction, feature selection, and classification methods that are used, on the performance of automatic detection of cyberbullying. To perform the exper...

  17. A method for extracting chaotic signal from noisy environment

    International Nuclear Information System (INIS)

    Shang, L.-J.; Shyu, K.-K.

    2009-01-01

    In this paper, we propose a approach for extracting chaos signal from noisy environment where the chaotic signal has been contaminated by white Gaussian noise. The traditional type of independent component analysis (ICA) is capable of separating mixed signals and retrieving them independently; however, the separated signal shows unreal amplitude. The results of this study show with our method the real chaos signal can be effectively recovered.

  18. Extractive method for obtaining gas inclusions from ice

    International Nuclear Information System (INIS)

    Strauch, G.; Kowski, P.

    1982-01-01

    Doubtless important for glaciological investigations of firn and ice is the knowledge about the chemical composition of gases included in ice. A method for quantitative extraction of gases from about 30 kg ice under vacuum is presented in this paper. The procedure was tested with ice cores from a thermoelectrical drill hole near Soviet Antarctic station Novolazarevskaya. The chemical compositions of inclusion gases and the specific gas contents from 6 horizons are pointed out by a table and some graphics. (author)

  19. Extraction of diagnostic parameters from the transient response of a porous electro ceramic gas sensor

    International Nuclear Information System (INIS)

    Hossein-Babaei, F.; Orvatinia, M.

    2004-01-01

    A novel concept for the diagnosis of a pure target gas in air is presented. The method employs a resistive gas sensor with a mm-thick highly porous electro ceramic gas sensitive body. The diagnosis is based on the fact that the diffusion time of the target gas through the porous body would depend on its molecular properties. The transient response of the device was analyzed based on a diffusion reaction equation. The solutions of the equation were shown to be of diagnostic merits. Such a device was fabricated by partial sintering of a Zn O body formed by low pressure pressing. The transient responses of the device to methanol, ethanol, poropanol and butanol were recorded. The analytical data, and the diagnostic parameters were resulted as the fitting parameters. Comparison of the parameters obtained with those available from the calibration experiments afforded target gas identification

  20. Methods for extracting social network data from chatroom logs

    Science.gov (United States)

    Osesina, O. Isaac; McIntire, John P.; Havig, Paul R.; Geiselman, Eric E.; Bartley, Cecilia; Tudoreanu, M. Eduard

    2012-06-01

    Identifying social network (SN) links within computer-mediated communication platforms without explicit relations among users poses challenges to researchers. Our research aims to extract SN links in internet chat with multiple users engaging in synchronous overlapping conversations all displayed in a single stream. We approached this problem using three methods which build on previous research. Response-time analysis builds on temporal proximity of chat messages; word context usage builds on keywords analysis and direct addressing which infers links by identifying the intended message recipient from the screen name (nickname) referenced in the message [1]. Our analysis of word usage within the chat stream also provides contexts for the extracted SN links. To test the capability of our methods, we used publicly available data from Internet Relay Chat (IRC), a real-time computer-mediated communication (CMC) tool used by millions of people around the world. The extraction performances of individual methods and their hybrids were assessed relative to a ground truth (determined a priori via manual scoring).

  1. Detecting epileptic seizure with different feature extracting strategies using robust machine learning classification techniques by applying advance parameter optimization approach.

    Science.gov (United States)

    Hussain, Lal

    2018-06-01

    Epilepsy is a neurological disorder produced due to abnormal excitability of neurons in the brain. The research reveals that brain activity is monitored through electroencephalogram (EEG) of patients suffered from seizure to detect the epileptic seizure. The performance of EEG detection based epilepsy require feature extracting strategies. In this research, we have extracted varying features extracting strategies based on time and frequency domain characteristics, nonlinear, wavelet based entropy and few statistical features. A deeper study was undertaken using novel machine learning classifiers by considering multiple factors. The support vector machine kernels are evaluated based on multiclass kernel and box constraint level. Likewise, for K-nearest neighbors (KNN), we computed the different distance metrics, Neighbor weights and Neighbors. Similarly, the decision trees we tuned the paramours based on maximum splits and split criteria and ensemble classifiers are evaluated based on different ensemble methods and learning rate. For training/testing tenfold Cross validation was employed and performance was evaluated in form of TPR, NPR, PPV, accuracy and AUC. In this research, a deeper analysis approach was performed using diverse features extracting strategies using robust machine learning classifiers with more advanced optimal options. Support Vector Machine linear kernel and KNN with City block distance metric give the overall highest accuracy of 99.5% which was higher than using the default parameters for these classifiers. Moreover, highest separation (AUC = 0.9991, 0.9990) were obtained at different kernel scales using SVM. Additionally, the K-nearest neighbors with inverse squared distance weight give higher performance at different Neighbors. Moreover, to distinguish the postictal heart rate oscillations from epileptic ictal subjects, and highest performance of 100% was obtained using different machine learning classifiers.

  2. Comparison of safflower oil extraction kinetics under two characteristic moisture conditions: statistical analysis of non-linear model parameters

    Directory of Open Access Journals (Sweden)

    E. Baümler

    2014-06-01

    Full Text Available In this study the kinetics of oil extraction from partially dehulled safflower seeds under two moisture conditions (7 and 9% dry basis was investigated. The extraction assays were performed using a stirred batch system, thermostated at 50 ºC, using n-hexane as solvent. The data obtained were fitted to a modified diffusion model in order to represent the extraction kinetics. The model took into account a washing and a diffusive step. Fitting parameters were compared statistically for both moisture conditions. The oil yield increased with the extraction time in both cases, although the oil was released at different rates. A comparison of the parameters showed that both the portion extracted in the washing phase and the effective diffusion coefficient were moisture-dependent. The effective diffusivities were 2.81 10-12 and 8.06 10-13 m²s-1 for moisture contents of 7% and 9%, respectively.

  3. Preventive effects of hydroalcoholic extract of saffron on hematological parameters of experimental asthmatic rats

    Directory of Open Access Journals (Sweden)

    Somayyeh Vosooghi

    2013-05-01

    Full Text Available Objective: Asthma is a chronic inflammatory disease of the respiratory airways distinguished by edema and infiltration of inflammatory immune cells. To test our hypothesis about the anti-inflammatory effect of saffron, we examined effects of Crocus sativus (C. sativus extract as a prophylactic anti-inflammatory agent in sensitized rats. Materials and Methods: To induce experimental asthma, rats were sensitized with injection and inhalation of ovalbumin (OA. Forty male Wistar rats were divided into 5 groups (n=8 for each: control, sensitized (asthma, and sensitized and pretreated with three different concentrations of extract, 50, 100, and 200 mg/kg, 2 times a week (group asthma+50EX, group asthma+100EX, and group asthma+200EX. After 32 days, total white blood cells (WBC counts, red blood cells (RBC, and platelet counts in blood were examined. Results: Total WBC number and eosinophil and neutrophil percentage in blood were increased, but lymphocyte decreased in sensitized animals compared with those of control group (pConclusion: Our findings indicated that the extract of C. sativus could be useful to prevent asthma as an anti-inflammatory treatment.

  4. Evaluating the influence of initial magnetization conditions on extracted exchange parameters in NMR relaxation experiments: applications to CPMG and CEST

    Energy Technology Data Exchange (ETDEWEB)

    Yuwen, Tairan; Sekhar, Ashok; Kay, Lewis E., E-mail: kay@pound.med.utoronto.ca [The University of Toronto, Departments of Molecular Genetics, Biochemistry and Chemistry (Canada)

    2016-08-15

    Transient excursions of native protein states to functionally relevant higher energy conformations often occur on the μs–ms timescale. NMR spectroscopy has emerged as an important tool to probe such processes using techniques such as Carr–Purcell–Meiboom–Gill (CPMG) relaxation dispersion and Chemical Exchange Saturation Transfer (CEST). The extraction of kinetic and structural parameters from these measurements is predicated upon mathematical modeling of the resulting relaxation profiles, which in turn relies on knowledge of the initial magnetization conditions at the start of the CPMG/CEST relaxation elements in these experiments. Most fitting programs simply assume initial magnetization conditions that are given by equilibrium populations, which may be incorrect in certain implementations of experiments. In this study we have quantified the systematic errors in extracted parameters that are generated from analyses of CPMG and CEST experiments using incorrect initial boundary conditions. We find that the errors in exchange rates (k{sub ex}) and populations (p{sub E}) are typically small (<10 %) and thus can be safely ignored in most cases. However, errors become larger and cannot be fully neglected (20–40 %) as k{sub ex} falls near the lower limit of each method or when short CPMG/CEST relaxation elements are used in these experiments. The source of the errors can be rationalized and their magnitude given by a simple functional form. Despite the fact that errors tend to be small, it is recommended that the correct boundary conditions be implemented in fitting programs so as to obtain as robust estimates of exchange parameters as possible.

  5. A Novel Extraction Approach of Extrinsic and Intrinsic Parameters of InGaAs/GaN pHEMTs

    Science.gov (United States)

    2015-07-01

    A Novel Extraction Approach of Extrinsic and Intrinsic Parameters of InGaAs/GaN pHEMTs Andong Huang1, 2, ZhengZhong2, 3, and Yongxin Guo2, 3...Suzhou Research Institute, Suzhou, China Abstract — A novel extraction approach of extrinsic and intrinsic parameters of InGaAs/GaN pHEMTs is...parameter error function. The extrinsic elements are optimized at multi-bias points and the intrinsic ones at specific bias points. Only broad ranges

  6. Intensification of extraction of curcumin from Curcuma amada using ultrasound assisted approach: Effect of different operating parameters.

    Science.gov (United States)

    Shirsath, S R; Sable, S S; Gaikwad, S G; Sonawane, S H; Saini, D R; Gogate, P R

    2017-09-01

    Curcumin, a dietary phytochemical, has been extracted from rhizomes of Curcuma amada using ultrasound assisted extraction (UAE) and the results compared with the conventional extraction approach to establish the process intensification benefits. The effect of operating parameters such as type of solvent, extraction time, extraction temperature, solid to solvent ratio, particle size and ultrasonic power on the extraction yield have been investigated in details for the approach UAE. The maximum extraction yield as 72% was obtained in 1h under optimized conditions of 35°C temperature, solid to solvent ratio of 1:25, particle size of 0.09mm, ultrasonic power of 250W and ultrasound frequency of 22kHz with ethanol as the solvent. The obtained yield was significantly higher as compared to the batch extraction where only about 62% yield was achieved in 8h of treatment. Peleg's model was used to describe the kinetics of UAE and the model showed a good agreement with the experimental results. Overall, ultrasound has been established to be a green process for extraction of curcumin with benefits of reduction in time as compared to batch extraction and the operating temperature as compared to Soxhlet extraction. Copyright © 2017. Published by Elsevier B.V.

  7. Validation of an HPLC method for quantification of total quercetin in Calendula officinalis extracts

    International Nuclear Information System (INIS)

    Muñoz Muñoz, John Alexander; Morgan Machado, Jorge Enrique; Trujillo González, Mary

    2015-01-01

    Introduction: calendula officinalis extracts are used as natural raw material in a wide range of pharmaceutical and cosmetic preparations; however, there are no official methods for quality control of these extracts. Objective: to validate an HPLC-based analytical method for quantification total quercetin in glycolic and hydroalcoholic extracts of Calendula officinalis. Methods: to quantify total quercetin content in the matrices, it was necessary to hydrolyze flavonoid glycosides under optimal conditions. The chromatographic separation was performed on a C-18 SiliaChrom 4.6x150 mm 5 µm column, adapted to a SiliaChrom 5 um C-18 4.6x10 mm precolumn, with UV detection at 370 nm. The gradient elution was performed with a mobile phase consisting of methanol (MeOH) and phosphoric acid (H 3 PO 4 ) (0.08 % w/v). The quantification was performed through the external standard method and comparison with quercetin reference standard. Results: the studied method selectivity against extract components and degradation products under acid/basic hydrolysis, oxidation and light exposure conditions showed no signals that interfere with the quercetin quantification. It was statistically proved that the method is linear from 1.0 to 5.0 mg/mL. Intermediate precision expressed as a variation coefficient was 1.8 and 1.74 % and the recovery percentage was 102.15 and 101.32 %, for glycolic and hydroalcoholic extracts, respectively. Conclusions: the suggested methodology meets the quality parameters required for quantifying total quercetin, which makes it a useful tool for quality control of C. officinalis extracts. (author)

  8. A standardized method for sampling and extraction methods for quantifying microplastics in beach sand.

    Science.gov (United States)

    Besley, Aiken; Vijver, Martina G; Behrens, Paul; Bosker, Thijs

    2017-01-15

    Microplastics are ubiquitous in the environment, are frequently ingested by organisms, and may potentially cause harm. A range of studies have found significant levels of microplastics in beach sand. However, there is a considerable amount of methodological variability among these studies. Methodological variation currently limits comparisons as there is no standard procedure for sampling or extraction of microplastics. We identify key sampling and extraction procedures across the literature through a detailed review. We find that sampling depth, sampling location, number of repeat extractions, and settling times are the critical parameters of variation. Next, using a case-study we determine whether and to what extent these differences impact study outcomes. By investigating the common practices identified in the literature with the case-study, we provide a standard operating procedure for sampling and extracting microplastics from beach sand. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. A comparative method for processing immunological parameters: developing an "Immunogram".

    Science.gov (United States)

    Ortolani, Riccardo; Bellavite, Paolo; Paiola, Fiorenza; Martini, Morena; Marchesini, Martina; Veneri, Dino; Franchini, Massimo; Chirumbolo, Salvatore; Tridente, Giuseppe; Vella, Antonio

    2010-04-01

    The immune system is a network of numerous cells that communicate both directly and indirectly with each other. The system is very sensitive to antigenic stimuli, which are memorised, and is closely connected with the endocrine and nervous systems. Therefore, in order to study the immune system correctly, it must be considered in all its complexity by analysing its components with multiparametric tools that take its dynamic characteristic into account. We analysed lymphocyte subpopulations by using monoclonal antibodies with six different fluorochromes; the monoclonal panel employed included CD45, CD3, CD4, CD8, CD16, CD56, CD57, CD19, CD23, CD27, CD5, and HLA-DR. This panel has enabled us to measure many lymphocyte subsets in different states and with different functions: helper, suppressor, activated, effector, naïve, memory, and regulatory. A database was created to collect the values of immunological parameters of approximately 8,000 subjects who have undergone testing since 2000. When the distributions of the values for these parameters were compared with the medians of reference values published in the literature, we found that most of the values from the subjects included in the database were close to the medians in the literature. To process the data we used a comparative method that calculates the percentile rank of the values of a subject by comparing them with the values for others subjects of the same age. From this data processing we obtained a set of percentile ranks that represent the positions of the various parameters with regard to the data for other age-matched subjects included in the database. These positions, relative to both the absolute values and percentages, are plotted in a graph. We have called the final plot, which can be likened to that subject's immunological fingerprint, an "Immunogram". In order to perform the necessary calculations automatically, we developed dedicated software (Immunogramma) which provides at least two different

  10. Gesture-Based Extraction of Robot Skill Parameters for Intuitive Robot Programming

    DEFF Research Database (Denmark)

    Pedersen, Mikkel Rath; Krüger, Volker

    2015-01-01

    a working system capable of TbD would be ideal. Contrary to current TbD approaches, that generally aim to recognize both action and where it is applied, we propose a division of labor, where the operator manually specifies the action the robot should perform, while gestures are used for specifying...... the relevant action parameter (e.g. on which object to apply the action). Using this two-step method has the advantages that there is no uncertainty of which action the robot will perform, it takes into account that the environment changes, so objects do not need to be at predefined locations......, and the parameter specification is possible even for inexperienced users. Experiments with 24 people in 3 different environments verify that it is indeed intuitive, even for a robotics novice, to program a mobile manipulator using this method....

  11. Bubble parameters analysis of gas-liquid two-phase sparse bubbly flow based on image method

    International Nuclear Information System (INIS)

    Zhou Yunlong; Zhou Hongjuan; Song Lianzhuang; Liu Qian

    2012-01-01

    The sparse rising bubbles of gas-liquid two-phase flow in vertical pipe were measured and studied based on image method. The bubble images were acquired by high-speed video camera systems, the characteristic parameters of bubbles were extracted by using image processing techniques. Then velocity variation of rising bubbles were drawn. Area and centroid variation of single bubble were also drawn. And then parameters and movement law of bubbles were analyzed and studied. The test results showed that parameters of bubbles had been analyzed well by using image method. (authors)

  12. Portable Rule Extraction Method for Neural Network Decisions Reasoning

    Directory of Open Access Journals (Sweden)

    Darius PLIKYNAS

    2005-08-01

    Full Text Available Neural network (NN methods are sometimes useless in practical applications, because they are not properly tailored to the particular market's needs. We focus thereinafter specifically on financial market applications. NNs have not gained full acceptance here yet. One of the main reasons is the "Black Box" problem (lack of the NN decisions explanatory power. There are though some NN decisions rule extraction methods like decompositional, pedagogical or eclectic, but they suffer from low portability of the rule extraction technique across various neural net architectures, high level of granularity, algorithmic sophistication of the rule extraction technique etc. The authors propose to eliminate some known drawbacks using an innovative extension of the pedagogical approach. The idea is exposed by the use of a widespread MLP neural net (as a common tool in the financial problems' domain and SOM (input data space clusterization. The feedback of both nets' performance is related and targeted through the iteration cycle by achievement of the best matching between the decision space fragments and input data space clusters. Three sets of rules are generated algorithmically or by fuzzy membership functions. Empirical validation of the common financial benchmark problems is conducted with an appropriately prepared software solution.

  13. Kernel methods for interpretable machine learning of order parameters

    Science.gov (United States)

    Ponte, Pedro; Melko, Roger G.

    2017-11-01

    Machine learning is capable of discriminating phases of matter, and finding associated phase transitions, directly from large data sets of raw state configurations. In the context of condensed matter physics, most progress in the field of supervised learning has come from employing neural networks as classifiers. Although very powerful, such algorithms suffer from a lack of interpretability, which is usually desired in scientific applications in order to associate learned features with physical phenomena. In this paper, we explore support vector machines (SVMs), which are a class of supervised kernel methods that provide interpretable decision functions. We find that SVMs can learn the mathematical form of physical discriminators, such as order parameters and Hamiltonian constraints, for a set of two-dimensional spin models: the ferromagnetic Ising model, a conserved-order-parameter Ising model, and the Ising gauge theory. The ability of SVMs to provide interpretable classification highlights their potential for automating feature detection in both synthetic and experimental data sets for condensed matter and other many-body systems.

  14. Determination of heterogeneous medium parameters by single fuel element method

    International Nuclear Information System (INIS)

    Veloso, M.A.F.

    1985-01-01

    The neutron pulse propagation technique was employed to study an heterogeneous system consisting of a single fuel element placed at the symmetry axis of a large cylindrical D 2 O tank. The response of system for the pulse propagation technique is related to the inverse complex relaxation length of the neutron waves also known as the system dispersion law ρ (ω). Experimental values of ρ (ω) were compared with the ones derived from Fermi age - Diffusion theory. The main purpose of the experiment was to obtain the Feinberg-Galanin thermal constant (γ), which is the logaritmic derivative of the neutron flux at the fuel-moderator interface and a such a main input data for heterogeneous reactor theory calculations. The γ thermal constant was determined as the number giving the best agreement between the theoretical and experimental values of ρ (ω). The simultaneous determination of two among four parameters η,ρ,τ and L s is possible through the intersection of dispersion laws of the pure moderator system and the fuel moderator system. The parameters τ and η were termined by this method. It was shown that the thermal constant γ and the product η ρ can be computed from the real and imaginary parts of the fuel-moderator dispersion law. The results for this evaluation scheme showns a not stable behavior of γ as a function of frequency, a result not foreseen by the theoretical model. (Author) [pt

  15. MODELING OF SUPERCRITICAL FLUID EXTRACTION KINETIC OF FLAXSEED OIL BY DIFFUSION CONTROL METHOD

    Directory of Open Access Journals (Sweden)

    Emir Zafer HOŞGÜN

    2013-06-01

    Full Text Available In this study, Flaxseed oil was extracted by Supercritical Carbondioxide Extraction, and extractionkinetics was modelled using diffusion controlled method.The effect of process parameters, such as pressure (20, 35, 55 MPa, temperature (323 and 343 K, and CO2 flow rate (1 and 3 L CO2 /min on the extraction yield and effective diffusivity (De was investigated. The effective diffusion coefficient varied between 2.4 x10-12 and 10.8 x10-12 m2s-1 for the entire range of experiments and increased with the pressure and flow rate. The model fitted well theexperimental data (ADD varied between 2.35 and 7.48%.

  16. Solvent extraction of aromatics from middle distillates: equilibria prediction method by group contribution

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, M.; Mikitenko, P.; Asselineau, L.

    1984-01-01

    A method of calculating liquid-liquid aromatics extraction of a middle distillate is described. The group contribution models of the ASOG and UNIFAC type are investigated. Four vapor liquid equilibrium (VLE), two solid-liquid equilibrium (SLE), three binary and six ternary liquid-liquid equilibrium (LLE) have been measured. The parameters of the models are based mainly on the data of the systems having 10-20 carbon number. VLE, SLE, and infinite dilution activity coefficient data (17-245/sup 0/C) have been used for calculating interaction parameters between hydrocarbon groups and LLE data (20-80/sup 0/C) for interaction parameters of dimethylformamide-hydrocarbon groups. Middle distillate representation is based on mass spectrometric and gas chromatographic analysis and on limited data of middle distillate-DMF liquid-liquid equilibrium. It is shown that the performance of ASOG and UNIFAC models are sufficiently valid in representation of data base and in extraction calculations. Considering the predictive character and the rapidity of its application this method can be useful in the preliminary study of extraction processes. 34 references, 2 figures, 10 tables.

  17. Design space development for the extraction process of Danhong injection using a Monte Carlo simulation method.

    Directory of Open Access Journals (Sweden)

    Xingchu Gong

    Full Text Available A design space approach was applied to optimize the extraction process of Danhong injection. Dry matter yield and the yields of five active ingredients were selected as process critical quality attributes (CQAs. Extraction number, extraction time, and the mass ratio of water and material (W/M ratio were selected as critical process parameters (CPPs. Quadratic models between CPPs and CQAs were developed with determination coefficients higher than 0.94. Active ingredient yields and dry matter yield increased as the extraction number increased. Monte-Carlo simulation with models established using a stepwise regression method was applied to calculate the probability-based design space. Step length showed little effect on the calculation results. Higher simulation number led to results with lower dispersion. Data generated in a Monte Carlo simulation following a normal distribution led to a design space with a smaller size. An optimized calculation condition was obtained with 10,000 simulation times, 0.01 calculation step length, a significance level value of 0.35 for adding or removing terms in a stepwise regression, and a normal distribution for data generation. The design space with a probability higher than 0.95 to attain the CQA criteria was calculated and verified successfully. Normal operating ranges of 8.2-10 g/g of W/M ratio, 1.25-1.63 h of extraction time, and two extractions were recommended. The optimized calculation conditions can conveniently be used in design space development for other pharmaceutical processes.

  18. AN ITERATIVE SEGMENTATION METHOD FOR REGION OF INTEREST EXTRACTION

    Directory of Open Access Journals (Sweden)

    Volkan CETIN

    2013-01-01

    Full Text Available In this paper, a method is presented for applications which include mammographic image segmentation and region of interest extraction. Segmentation is a very critical and difficult stage to accomplish in computer aided detection systems. Although the presented segmentation method is developed for mammographic images, it can be used for any medical image which resembles the same statistical characteristics with mammograms. Fundamentally, the method contains iterative automatic thresholding and masking operations which is applied to the original or enhanced mammograms. Also the effect of image enhancement to the segmentation process was observed. A version of histogram equalization was applied to the images for enhancement. Finally, the results show that enhanced version of the proposed segmentation method is preferable because of its better success rate.

  19. Advanced Extraction Methods for Actinide/Lanthanide Separations

    International Nuclear Information System (INIS)

    Scott, M.J.

    2005-01-01

    The separation of An(III) ions from chemically similar Ln(III) ions is perhaps one of the most difficult problems encountered during the processing of nuclear waste. In the 3+ oxidation states, the metal ions have an identical charge and roughly the same ionic radius. They differ strictly in the relative energies of their f- and d-orbitals, and to separate these metal ions, ligands will need to be developed that take advantage of this small but important distinction. The extraction of uranium and plutonium from nitric acid solution can be performed quantitatively by the extraction with the TBP (tributyl phosphate). Commercially, this process has found wide use in the PUREX (plutonium uranium extraction) reprocessing method. The TRUEX (transuranium extraction) process is further used to coextract the trivalent lanthanides and actinides ions from HLLW generated during PUREX extraction. This method uses CMPO [(N, N-diisobutylcarbamoylmethyl) octylphenylphosphineoxide] intermixed with TBP as a synergistic agent. However, the final separation of trivalent actinides from trivalent lanthanides still remains a challenging task. In TRUEX nitric acid solution, the Am(III) ion is coordinated by three CMPO molecules and three nitrate anions. Taking inspiration from this data and previous work with calix[4]arene systems, researchers on this project have developed a C3-symmetric tris-CMPO ligand system using a triphenoxymethane platform as a base. The triphenoxymethane ligand systems have many advantages for the preparation of complex ligand systems. The compounds are very easy to prepare. The steric and solubility properties can be tuned through an extreme range by the inclusion of different alkoxy and alkyl groups such as methyoxy, ethoxy, t-butoxy, methyl, octyl, t-pentyl, or even t-pentyl at the ortho- and para-positions of the aryl rings. The triphenoxymethane ligand system shows promise as an improved extractant for both tetravalent and trivalent actinide recoveries form

  20. Advanced Extraction Methods for Actinide/Lanthanide Separations

    Energy Technology Data Exchange (ETDEWEB)

    Scott, M.J.

    2005-12-01

    The separation of An(III) ions from chemically similar Ln(III) ions is perhaps one of the most difficult problems encountered during the processing of nuclear waste. In the 3+ oxidation states, the metal ions have an identical charge and roughly the same ionic radius. They differ strictly in the relative energies of their f- and d-orbitals, and to separate these metal ions, ligands will need to be developed that take advantage of this small but important distinction. The extraction of uranium and plutonium from nitric acid solution can be performed quantitatively by the extraction with the TBP (tributyl phosphate). Commercially, this process has found wide use in the PUREX (plutonium uranium extraction) reprocessing method. The TRUEX (transuranium extraction) process is further used to coextract the trivalent lanthanides and actinides ions from HLLW generated during PUREX extraction. This method uses CMPO [(N, N-diisobutylcarbamoylmethyl) octylphenylphosphineoxide] intermixed with TBP as a synergistic agent. However, the final separation of trivalent actinides from trivalent lanthanides still remains a challenging task. In TRUEX nitric acid solution, the Am(III) ion is coordinated by three CMPO molecules and three nitrate anions. Taking inspiration from this data and previous work with calix[4]arene systems, researchers on this project have developed a C3-symmetric tris-CMPO ligand system using a triphenoxymethane platform as a base. The triphenoxymethane ligand systems have many advantages for the preparation of complex ligand systems. The compounds are very easy to prepare. The steric and solubility properties can be tuned through an extreme range by the inclusion of different alkoxy and alkyl groups such as methyoxy, ethoxy, t-butoxy, methyl, octyl, t-pentyl, or even t-pentyl at the ortho- and para-positions of the aryl rings. The triphenoxymethane ligand system shows promise as an improved extractant for both tetravalent and trivalent actinide recoveries form

  1. Feature extraction from mammographic images using fast marching methods

    International Nuclear Information System (INIS)

    Bottigli, U.; Golosio, B.

    2002-01-01

    Features extraction from medical images represents a fundamental step for shape recognition and diagnostic support. The present work faces the problem of the detection of large features, such as massive lesions and organ contours, from mammographic images. The regions of interest are often characterized by an average grayness intensity that is different from the surrounding. In most cases, however, the desired features cannot be extracted by simple gray level thresholding, because of image noise and non-uniform density of the surrounding tissue. In this work, edge detection is achieved through the fast marching method (Level Set Methods and Fast Marching Methods, Cambridge University Press, Cambridge, 1999), which is based on the theory of interface evolution. Starting from a seed point in the shape of interest, a front is generated which evolves according to an appropriate speed function. Such function is expressed in terms of geometric properties of the evolving interface and of image properties, and should become zero when the front reaches the desired boundary. Some examples of application of such method to mammographic images from the CALMA database (Nucl. Instr. and Meth. A 460 (2001) 107) are presented here and discussed

  2. 3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea.

    Science.gov (United States)

    Zhao, Mingtao; Kuo, Anthony N; Izatt, Joseph A

    2010-04-26

    Capable of three-dimensional imaging of the cornea with micrometer-scale resolution, spectral domain-optical coherence tomography (SDOCT) offers potential advantages over Placido ring and Scheimpflug photography based systems for accurate extraction of quantitative keratometric parameters. In this work, an SDOCT scanning protocol and motion correction algorithm were implemented to minimize the effects of patient motion during data acquisition. Procedures are described for correction of image data artifacts resulting from 3D refraction of SDOCT light in the cornea and from non-idealities of the scanning system geometry performed as a pre-requisite for accurate parameter extraction. Zernike polynomial 3D reconstruction and a recursive half searching algorithm (RHSA) were implemented to extract clinical keratometric parameters including anterior and posterior radii of curvature, central cornea optical power, central corneal thickness, and thickness maps of the cornea. Accuracy and repeatability of the extracted parameters obtained using a commercial 859nm SDOCT retinal imaging system with a corneal adapter were assessed using a rigid gas permeable (RGP) contact lens as a phantom target. Extraction of these parameters was performed in vivo in 3 patients and compared to commercial Placido topography and Scheimpflug photography systems. The repeatability of SDOCT central corneal power measured in vivo was 0.18 Diopters, and the difference observed between the systems averaged 0.1 Diopters between SDOCT and Scheimpflug photography, and 0.6 Diopters between SDOCT and Placido topography.

  3. Physically based model for extracting dual permeability parameters using non-Newtonian fluids

    Science.gov (United States)

    Abou Najm, M. R.; Basset, C.; Stewart, R. D.; Hauswirth, S.

    2017-12-01

    Dual permeability models are effective for the assessment of flow and transport in structured soils with two dominant structures. The major challenge to those models remains in the ability to determine appropriate and unique parameters through affordable, simple, and non-destructive methods. This study investigates the use of water and a non-Newtonian fluid in saturated flow experiments to derive physically-based parameters required for improved flow predictions using dual permeability models. We assess the ability of these two fluids to accurately estimate the representative pore sizes in dual-domain soils, by determining the effective pore sizes of macropores and micropores. We developed two sub-models that solve for the effective macropore size assuming either cylindrical (e.g., biological pores) or planar (e.g., shrinkage cracks and fissures) pore geometries, with the micropores assumed to be represented by a single effective radius. Furthermore, the model solves for the percent contribution to flow (wi) corresponding to the representative macro and micro pores. A user-friendly solver was developed to numerically solve the system of equations, given that relevant non-Newtonian viscosity models lack forms conducive to analytical integration. The proposed dual-permeability model is a unique attempt to derive physically based parameters capable of measuring dual hydraulic conductivities, and therefore may be useful in reducing parameter uncertainty and improving hydrologic model predictions.

  4. The effect of extracts of Irvingia gabonensis (IGOB131 and Dichrostachys glomerata (Dyglomera™ on body weight and lipid parameters of healthy overweight participants

    Directory of Open Access Journals (Sweden)

    Boris Azantsa

    2015-06-01

    Full Text Available Background: Previous work reported the benefits of extracts of 2 Cameroonian spices – Irvingia gabonensis and Dichrostachys glomerata— on obese people with metabolic syndrome. Considering the physio-metabolic changes that accompany obesity, the present study investigates the effects of these extracts on healthy overweight participants over an 8-week test period. Methods: The study was an 8 week randomized double-blind, placebo controlled design involving 48 overweight (BMI 26 – 30 participants (27 females and 19 males, divided into 3 groups – placebo, 300 mg I. gabonensis extract (IGOB131, or 300 mg D. glomerata extract (DyglomeraTM. Capsules containing the placebo or the test formulations were administered once daily before the main meal of the day. No major dietary changes or changes in physical activity were demonstrated during the study. Weight and blood lipid parameters were measured at baseline, and at the 4 and 8 weeks interval. Results: Compared to the placebo group, there were significant (p<0.05 reductions in weight of participants in both test groups over the 8 week period. However, these significant changes were not observed in the initial 4 weeks, even though the lipid parameters in the test groups changed significantly (p<0.05. Conclusion: The extracts of Irvingia gabonensis and Dichrostachys glomerata, at a dose of 300 mg per day, were effective in reducing weight and positively modifying lipid parameters in healthy overweight participants.

  5. Effects of dietary administration of yarrow extract on growth performance and blood biochemical parameters of rainbow trout (Oncorhynchus mykiss

    Directory of Open Access Journals (Sweden)

    Mahmoud Nafisi Bahabadi

    2014-10-01

    Full Text Available The present study was conducted to investigate the clinical effects and possible side effects of yarrow extract (Achillea millefolium L. as feed additive on biochemical blood parameters and growth performance of rainbow trout (Oncorhynchus mykiss. Fishes were treated with 0 (control, 0.1, 0.5 and 1% of yarrow extract for 30 days. Plasma alanine aminotransferase (ALT, aspartate aminotransferase (AST, lactate dehydrogenase (LDH, alkaline phosphatase (ALP, creatine kinase (CK, peroxidase activity, total complement and lysozyme activity, glucose, total protein, triglyceride and cholesterol were measured after 15 and 30 days of yarrow treatment. There were no significant changes in the lysozyme activity and glucose levels. Total protein and globulin levels were significantly higher in the fish fed with diets enriched with 1% yarrow extract on day 30. Triglyceride and cholesterol levels was significantly decreased in the fish fed with diets containing 0.5% and 1% yarrow extract on day 30 (P<0.05. LDH, CK and peroxidase activities in the fish fed with diets having 1% yarrow extract were significantly decreased at the end of the experiment (P<0.05. In contrast, a significant increase in AST, ALP and total complement activity was observed in the fish fed with 1% yarrow extract diet, on day 15 (P<0.05. The weight gain and specific growth rate increased and food conversion ratio decreased in in the fish fed 1% yarrow extract on day 30. Condition factor in the fish fed with yarrow extract was significantly higher than control group on 30 day. In conclusion, on the basis of these results, oral administration of yarrow extract up to 0.5% have not side effect on blood biochemical and clinical parameters of fishes. However, oral administration of 1% of yarrow extract caused cytotoxicity and modifications in blood biochemical parameters of fish.

  6. Development, validation and evaluation of an analytical method for the determination of monomeric and oligomeric procyanidins in apple extracts.

    Science.gov (United States)

    Hollands, Wendy J; Voorspoels, Stefan; Jacobs, Griet; Aaby, Kjersti; Meisland, Ane; Garcia-Villalba, Rocio; Tomas-Barberan, Francisco; Piskula, Mariusz K; Mawson, Deborah; Vovk, Irena; Needs, Paul W; Kroon, Paul A

    2017-04-28

    There is a lack of data for individual oligomeric procyanidins in apples and apple extracts. Our aim was to develop, validate and evaluate an analytical method for the separation, identification and quantification of monomeric and oligomeric flavanols in apple extracts. To achieve this, we prepared two types of flavanol extracts from freeze-dried apples; one was an epicatechin-rich extract containing ∼30% (w/w) monomeric (-)-epicatechin which also contained oligomeric procyanidins (Extract A), the second was an oligomeric procyanidin-rich extract depleted of epicatechin (Extract B). The parameters considered for method optimisation were HPLC columns and conditions, sample heating, mass of extract and dilution volumes. The performance characteristics considered for method validation included standard linearity, method sensitivity, precision and trueness. Eight laboratories participated in the method evaluation. Chromatographic separation of the analytes was best achieved utilizing a Hilic column with a binary mobile phase consisting of acidic acetonitrile and acidic aqueous methanol. The final method showed linearity for epicatechin in the range 5-100μg/mL with a correlation co-efficient >0.999. Intra-day and inter-day precision of the analytes ranged from 2 to 6% and 2 to 13% respectively. Up to dp3, trueness of the method was >95% but decreased with increasing dp. Within laboratory precision showed RSD values <5 and 10% for monomers and oligomers, respectively. Between laboratory precision was 4 and 15% (Extract A) and 7 and 30% (Extract B) for monomers and oligomers, respectively. An analytical method for the separation, identification and quantification of procyanidins in an apple extract was developed, validated and assessed. The results of the inter-laboratory evaluation indicate that the method is reliable and reproducible. Copyright © 2017. Published by Elsevier B.V.

  7. Effects of Aqueous Root Bark Extracts of Anogeissusleiocarpus (DC Guill&Perrand TerminaliaavicennioidesGuill&Perr on Redox and Haematological Parameters of Diethylnitrosamine-Administered Rats

    Directory of Open Access Journals (Sweden)

    Amadu Kayode Salau

    2015-11-01

    Full Text Available Background: This study investigated the protective effects of aqueous extracts of Anogeissusleiocarpus (DC Guill&Perr (family: Combretaceae and Terminaliaavicennioides Guill&Perr (family: Combretaceae root barks, as well as their 1:1 (w/w mixture on liver redox and haematological parameters of diethylnitrosamine-treated rats. Methods: Rats were orally administered distilled water, diethylnitrosamine (30 mg/kg body weight once a week on weeks 3 and 4, curcumin (200 mg/kg body weight, extracts and 1:1 mixture (200, 400 and 800 mg/kg body weight for 4 weeks. Malondialdehyde, markers of oxidative stress and hematological indices were evaluated. Results: The extracts and their mixture significantly (P<0.05 reversed the diethylnitrosamine-induced alterations in the levels of liver malondialdehyde, superoxide dismutase, catalase, glutathione peroxidase, glutathione reductase, glucose 6-phosphate dehydrogenase, glutathione, vitamin C and platelet counts. The other haematological parameters (red blood cell count, haemoglobin concentration, packed cell volume, mean corpuscular volume, mean corpuscular haemoglobin, mean corpuscular haemoglobin concentration, white blood cell count, lymphocyte count and neutrophil count were not affected by diethylnitrosamine and extracts. Conclusion: The extracts possess antioxidant, hepatoprotective and haemoprotective activities that compared well with curcumin. These activities were better exhibited by the mixture than the individual extracts.

  8. Effects of Feature Extraction and Classification Methods on Cyberbully Detection

    Directory of Open Access Journals (Sweden)

    Esra SARAÇ

    2016-12-01

    Full Text Available Cyberbullying is defined as an aggressive, intentional action against a defenseless person by using the Internet, or other electronic contents. Researchers have found that many of the bullying cases have tragically ended in suicides; hence automatic detection of cyberbullying has become important. In this study we show the effects of feature extraction, feature selection, and classification methods that are used, on the performance of automatic detection of cyberbullying. To perform the experiments FormSpring.me dataset is used and the effects of preprocessing methods; several classifiers like C4.5, Naïve Bayes, kNN, and SVM; and information gain and chi square feature selection methods are investigated. Experimental results indicate that the best classification results are obtained when alphabetic tokenization, no stemming, and no stopwords removal are applied. Using feature selection also improves cyberbully detection performance. When classifiers are compared, C4.5 performs the best for the used dataset.

  9. A method of ECG template extraction for biometrics applications.

    Science.gov (United States)

    Zhou, Xiang; Lu, Yang; Chen, Meng; Bao, Shu-Di; Miao, Fen

    2014-01-01

    ECG has attracted widespread attention as one of the most important non-invasive physiological signals in healthcare-system related biometrics for its characteristics like ease-of-monitoring, individual uniqueness as well as important clinical value. This study proposes a method of dynamic threshold setting to extract the most stable ECG waveform as the template for the consequent ECG identification process. With the proposed method, the accuracy of ECG biometrics using the dynamic time wraping for difference measures has been significantly improved. Analysis results with the self-built electrocardiogram database show that the deployment of the proposed method was able to reduce the half total error rate of the ECG biometric system from 3.35% to 1.45%. Its average running time on the platform of android mobile terminal was around 0.06 seconds, and thus demonstrates acceptable real-time performance.

  10. Method of extracting heat from dry geothermal reservoirs

    Science.gov (United States)

    Potter, R.M.; Robinson, E.S.; Smith, M.C.

    1974-01-22

    Hydraulic fracturing is used to interconnect two or more holes that penetrate a previously dry geothermal reservoir, and to produce within the reservoir a sufficiently large heat-transfer surface so that heat can be extracted from the reservoir at a usefully high rate by a fluid entering it through one hole and leaving it through another. Introduction of a fluid into the reservoir to remove heat from it and establishment of natural (unpumped) convective circulation through the reservoir to accomplish continuous heat removal are important and novel features of the method. (auth)

  11. Antifouling booster biocide extraction from marine sediments: a fast and simple method based on vortex-assisted matrix solid-phase extraction.

    Science.gov (United States)

    Caldas, Sergiane Souza; Soares, Bruno Meira; Abreu, Fiamma; Castro, Ítalo Braga; Fillmann, Gilberto; Primel, Ednei Gilberto

    2018-03-01

    This paper reports the development of an analytical method employing vortex-assisted matrix solid-phase dispersion (MSPD) for the extraction of diuron, Irgarol 1051, TCMTB (2-thiocyanomethylthiobenzothiazole), DCOIT (4,5-dichloro-2-n-octyl-3-(2H)-isothiazolin-3-one), and dichlofluanid from sediment samples. Separation and determination were performed by liquid chromatography tandem-mass spectrometry. Important MSPD parameters, such as sample mass, mass of C18, and type and volume of extraction solvent, were investigated by response surface methodology. Quantitative recoveries were obtained with 2.0 g of sediment sample, 0.25 g of C18 as the solid support, and 10 mL of methanol as the extraction solvent. The MSPD method was suitable for the extraction and determination of antifouling biocides in sediment samples, with recoveries between 61 and 103% and a relative standard deviation lower than 19%. Limits of quantification between 0.5 and 5 ng g -1 were obtained. Vortex-assisted MPSD was shown to be fast and easy to use, with the advantages of low cost and reduced solvent consumption compared to the commonly employed techniques for the extraction of booster biocides from sediment samples. Finally, the developed method was applied to real samples. Results revealed that the developed extraction method is effective and simple, thus allowing the determination of biocides in sediment samples.

  12. THE INFLUENCE OF TEMPERATURE AND TIME ON THE ANTIOXIDANT ACTIVITY AND COLOR PARAMETERS OF DOG-ROSE (ROSA CANINA ETHANOLIC EXTRACT

    Directory of Open Access Journals (Sweden)

    ELENA CRISTEA

    2016-07-01

    Full Text Available This paper presents the study of the stability of antioxidant activity and color of the 50 % ethanolic extract of dog-rose (Rosa canina from the Republic of Moldova with the main objective to test a food dye of natural origin. The extract was submitted to: -2 °C for 12 hours; 4 °C for 12 hours; 40 °C for 15 minutes, 60 °C for 15 minutes, 80 °C for 15 minutes and 100 °C for 2 minutes, after which the antioxidant activity and the color (CIELab parameters were measured. Three sets of extracts were kept for 2 weeks at -2 °C; 4 °C and 25 - 30 °C and afterwards the parameters mentioned above were measured once again. Moreover, the total content of polyphenols was determined by Folin-Ciocalteu method. The results were expressed in mg gallic acid equivalents per liter. The antioxidant activity was determined using the method based on the interaction with the ABTS radical, the results being expressed in mmol trolox equivalent per liter. Thermal treatments have not influenced antioxidant activity, but have significantly affected the extract by increasing its luminosity and changing the red/green parameter towards more red tones, while storage at -2 °C caused the decrease of yellowness. Storage at 4 °C was found to be optimal for the preservation of the antioxidant activity.

  13. Optimization of Ultrasonic-Assisted Extraction of Flavonoid Compounds and Antioxidants from Alfalfa Using Response Surface Method

    Directory of Open Access Journals (Sweden)

    Chang-Liang Jing

    2015-08-01

    Full Text Available Ultrasonic-assisted extraction (UAE was used to extract flavonoid-enriched antioxidants from alfalfa aerial part. Response surface methodology (RSM, based on a four-factor, five-level central composite design (CCD, was employed to obtain the optimal extraction parameters, in which the flavonoid content was maximum and the antioxidant activity of the extracts was strongest. Radical scavenging capacity of the extracts, which represents the amounts of antioxidants in alfalfa, was determined by using 2,2′-azino-bis (3-ethylbenzothiazoline-6-sulphonicacid (ABTS and 2,2′-diphenyl-1-picrylhydrazyl (DPPH methods. The results showed good fit with the proposed models for the total flavonoid extraction (R2 = 0.9849, for the antioxidant extraction assayed by ABTS method (R2 = 0.9764, and by DPPH method (R2 = 0.9806. Optimized extraction conditions for total flavonoids was a ratio of liquid to solid of 57.16 mL/g, 62.33 °C, 57.08 min, and 52.14% ethanol. The optimal extraction parameters of extracts for the highest antioxidant activity by DPPH method was a ratio of liquid to solid 60.3 mL/g, 54.56 °C, 45.59 min, and 46.67% ethanol, and by ABTS assay was a ratio of liquid to solid 47.29 mL/g, 63.73 °C, 51.62 min, and 60% ethanol concentration. Our work offers optimal extraction conditions for total flavonoids and antioxidants from alfalfa.

  14. Optimization of Ultrasonic-Assisted Extraction of Flavonoid Compounds and Antioxidants from Alfalfa Using Response Surface Method.

    Science.gov (United States)

    Jing, Chang-Liang; Dong, Xiao-Fang; Tong, Jian-Ming

    2015-08-26

    Ultrasonic-assisted extraction (UAE) was used to extract flavonoid-enriched antioxidants from alfalfa aerial part. Response surface methodology (RSM), based on a four-factor, five-level central composite design (CCD), was employed to obtain the optimal extraction parameters, in which the flavonoid content was maximum and the antioxidant activity of the extracts was strongest. Radical scavenging capacity of the extracts, which represents the amounts of antioxidants in alfalfa, was determined by using 2,2'-azino-bis (3-ethylbenzothiazoline-6-sulphonicacid) (ABTS) and 2,2'-diphenyl-1-picrylhydrazyl (DPPH) methods. The results showed good fit with the proposed models for the total flavonoid extraction (R² = 0.9849), for the antioxidant extraction assayed by ABTS method (R² = 0.9764), and by DPPH method (R² = 0.9806). Optimized extraction conditions for total flavonoids was a ratio of liquid to solid of 57.16 mL/g, 62.33 °C, 57.08 min, and 52.14% ethanol. The optimal extraction parameters of extracts for the highest antioxidant activity by DPPH method was a ratio of liquid to solid 60.3 mL/g, 54.56 °C, 45.59 min, and 46.67% ethanol, and by ABTS assay was a ratio of liquid to solid 47.29 mL/g, 63.73 °C, 51.62 min, and 60% ethanol concentration. Our work offers optimal extraction conditions for total flavonoids and antioxidants from alfalfa.

  15. Effect of Ethanolic Extract of Emblica officinalis on Histopathology of Kidney and on Biochemical Parameters in Hyperlipidemic Albino Rats

    Directory of Open Access Journals (Sweden)

    Bheemshetty S. Patil

    2015-01-01

    Full Text Available Background: It has been reported that hyperlipidemia plays a central role in the development of atherosclerosis and oxidative stress. Embilica officinalis also known as Amla or Indian Gooseberry acts as antihyperlipidemic and antioxidant. Its active ingredients contains tannins, gallic acid and flavonoids. Aim & Objectives: It was aimed to evaluate the effect of ethanolic extract of Emblica officinalis on histopathology of kidney and on biochemical parameters in hyperlipidemic albino Wistar rats. Material and Methods: Extraction of dried fruits of Emblica officinalis was done by Soxhlet apparatus 0 using 99% ethanol at 60 C for 24 hours and also phytochemical analysis was done. Group I served as normal control. Group II was fed with isocaloric diet. Group III was fed with hyperlipidemic diet. Group IV was fed with isocaloric diet for 21 days + Embilica officinalis for 21 days. Group V was fed with hyperlipidemic diet for 21 days+ Embilica officinalis for 21 days. The dose of ethanolic extract of Emblica officinalis was taken as 100mg/kg body weight daily. Results: Percent body weight gain, kidney weight and nephro-somatic index significantly improved in hyperlipidemic rats treated with Emblica officinalis. There was a significant improvement in serum electrolyte and kidney markers. It was found that there were focal glomerular lesions with thickening of glomerulus in the kidneys of rats on hyperlipidemic diet and normal renal histology of rats on hyperlipidemic diet treated with Emblica officinalis. Conclusion: It can be concluded that Emblica officinalis may be a good, natural therapeutic agent against hyperlipidemic diet induced oxidative damage and nephrotoxicity.

  16. 3D numerical simulations of negative hydrogen ion extraction using realistic plasma parameters, geometry of the extraction aperture and full 3D magnetic field map

    Science.gov (United States)

    Mochalskyy, S.; Wünderlich, D.; Ruf, B.; Franzen, P.; Fantz, U.; Minea, T.

    2014-02-01

    Decreasing the co-extracted electron current while simultaneously keeping negative ion (NI) current sufficiently high is a crucial issue on the development plasma source system for ITER Neutral Beam Injector. To support finding the best extraction conditions the 3D Particle-in-Cell Monte Carlo Collision electrostatic code ONIX (Orsay Negative Ion eXtraction) has been developed. Close collaboration with experiments and other numerical models allows performing realistic simulations with relevant input parameters: plasma properties, geometry of the extraction aperture, full 3D magnetic field map, etc. For the first time ONIX has been benchmarked with commercial positive ions tracing code KOBRA3D. A very good agreement in terms of the meniscus position and depth has been found. Simulation of NI extraction with different e/NI ratio in bulk plasma shows high relevance of the direct negative ion extraction from the surface produced NI in order to obtain extracted NI current as in the experimental results from BATMAN testbed.

  17. Effects of processing parameters on the caffeine extraction yield during decaffeination of black tea using pilot-scale supercritical carbon dioxide extraction technique.

    Science.gov (United States)

    Ilgaz, Saziye; Sat, Ihsan Gungor; Polat, Atilla

    2018-04-01

    In this pilot-scale study supercritical carbon dioxide (SCCO 2 ) extraction technique was used for decaffeination of black tea. Pressure (250, 375, 500 bar), extraction time (60, 180, 300 min), temperature (55, 62.5, 70 °C), CO 2 flow rate (1, 2, 3 L/min) and modifier quantity (0, 2.5, 5 mol%) were selected as extraction parameters. Three-level and five-factor response surface methodology experimental design with a Box-Behnken type was employed to generate 46 different processing conditions. 100% of caffeine from black tea was removed under two different extraction conditions; one of which was consist of 375 bar pressure, 62.5 °C temperature, 300 min extraction time, 2 L/min CO 2 flow rate and 5 mol% modifier concentration and the other was composed of same temperature, pressure and extraction time conditions with 3 L/min CO 2 flow rate and 2.5 mol% modifier concentration. Results showed that extraction time, pressure, CO 2 flow rate and modifier quantity had great impact on decaffeination yield.

  18. Lambert W-function based exact representation for double diode model of solar cells: Comparison on fitness and parameter extraction

    International Nuclear Information System (INIS)

    Gao, Xiankun; Cui, Yan; Hu, Jianjun; Xu, Guangyin; Yu, Yongchang

    2016-01-01

    Highlights: • Lambert W-function based exact representation (LBER) is presented for double diode model (DDM). • Fitness difference between LBER and DDM is verified by reported parameter values. • The proposed LBER can better represent the I–V and P–V characteristics of solar cells. • Parameter extraction difference between LBER and DDM is validated by two algorithms. • The parameter values extracted from LBER are more accurate than those from DDM. - Abstract: Accurate modeling and parameter extraction of solar cells play an important role in the simulation and optimization of PV systems. This paper presents a Lambert W-function based exact representation (LBER) for traditional double diode model (DDM) of solar cells, and then compares their fitness and parameter extraction performance. Unlike existing works, the proposed LBER is rigorously derived from DDM, and in LBER the coefficients of Lambert W-function are not extra parameters to be extracted or arbitrary scalars but the vectors of terminal voltage and current of solar cells. The fitness difference between LBER and DDM is objectively validated by the reported parameter values and experimental I–V data of a solar cell and four solar modules from different technologies. The comparison results indicate that under the same parameter values, the proposed LBER can better represent the I–V and P–V characteristics of solar cells and provide a closer representation to actual maximum power points of all module types. Two different algorithms are used to compare the parameter extraction performance of LBER and DDM. One is our restart-based bound constrained Nelder-Mead (rbcNM) algorithm implemented in Matlab, and the other is the reported R_c_r-IJADE algorithm executed in Visual Studio. The comparison results reveal that, the parameter values extracted from LBER using two algorithms are always more accurate and robust than those from DDM despite more time consuming. As an improved version of DDM, the

  19. Application of ultrasonic extraction method in the preparation of the directive action beverage from black currant

    Directory of Open Access Journals (Sweden)

    N. S. Rodionova

    2016-01-01

    Full Text Available The article presents the results of experimental determination of physical-and chemical parameters, the amount of anthocyanins, the definition of color and organoleptic characteristics of the beverage prepared with ultrasonic extraction method in comparison with the fruit-drink, obtained according to traditional recipe. Black currant was chosen the main raw material for the development of the beverage production technology. It is characterized by a high content of bioactive components that increase the adaptive abilities of human body. The purpose is to use ultrasonic extraction method in the preparation of functionally directed actions beverages. Extractor with submerged ultrasonic emitter was used as an experimental device. The essence of its operation is as follows: a mixture of the extractant and the plant substrate in different ratios was loaded into a container with the emitter, then the ultrasonic generator was turned on. The vibrations of ultrasonic frequency (22 kHz made high-frequency mechanical vibrations that caused the formation of intense cavitation areas and diffuse dissolution of cell substrates in the extractant in the treated mixture. The ultrasonic extraction technique involves brief contact of berries and extractant (up to 15 minutes upon application of ultrasonic vibrations. With an increase in exposure time, the yield of biologically active substances increases to reach an equilibrium state corresponding to the most complete exhaustion of raw materials. All this leads to a significant acceleration of the transition from the active ingredients from the raw materials into the extractant to obtain a product with improved physical - and chemical, organoleptic characteristics, as well as a higher antioxidant activity.

  20. Effects of methanolic extract of Moringa oleifera leaves on semen and biochemical parameters in cryptorchid rats.

    Science.gov (United States)

    Afolabi, Ayobami Oladele; Aderoju, Hameed Adeola; Alagbonsi, Isiaka Abdullateef

    2013-01-01

    While anti-oxidant effects of Moringa oleifera in much oxidative stress related diseases have been well reported, cryptorchidism on the other hand has been shown to cause oxidative stress. However, study is scanty on the likely role of Moringa oleifera in reducing cryptorchidism-induced oxidative stress in rats has not been studied. The present study looked into the effects of methanolic extract of Moringa oleifera leaves (MEMO) on semen and biochemical parameters in cryptorchid rats. Twenty male albino rats (200-250 g) were randomly divided into 4 groups (n=5 each). Groups A and B were sham-operated and treated with corn-oil and 200 mg/kg of MEMO respectively, while groups C and D were rendered cryptorchid and also treated with corn-oil and 200 mg/kg of MEMO respectively. Cryptorchid rats had lower testicular weight, sperm count, germ cell count, testicular superoxide dismutase (SOD) concentration, testicular total protein and higher testicular malondialdehyde (MDA) concentration compared to sham-operated rats. MEMO had no significant effect on testicular weight and MDA concentration, while it significantly increased sperm count, germ cell count, testicular SOD and total protein in the cryptorchid rats. The present study suggests that MEMO ameliorates cryptorchidism associated germ cell loss and oxidative stress.

  1. Direct extraction of electron parameters from magnetoconductance analysis in mesoscopic ring array structures

    Science.gov (United States)

    Sawada, A.; Faniel, S.; Mineshige, S.; Kawabata, S.; Saito, K.; Kobayashi, K.; Sekine, Y.; Sugiyama, H.; Koga, T.

    2018-05-01

    We report an approach for examining electron properties using information about the shape and size of a nanostructure as a measurement reference. This approach quantifies the spin precession angles per unit length directly by considering the time-reversal interferences on chaotic return trajectories within mesoscopic ring arrays (MRAs). Experimentally, we fabricated MRAs using nanolithography in InGaAs quantum wells which had a gate-controllable spin-orbit interaction (SOI). As a result, we observed an Onsager symmetry related to relativistic magnetic fields, which provided us with indispensable information for the semiclassical billiard ball simulation. Our simulations, developed based on the real-space formalism of the weak localization/antilocalization effect including the degree of freedom for electronic spin, reproduced the experimental magnetoconductivity (MC) curves with high fidelity. The values of five distinct electron parameters (Fermi wavelength, spin precession angles per unit length for two different SOIs, impurity scattering length, and phase coherence length) were thereby extracted from a single MC curve. The methodology developed here is applicable to wide ranges of nanomaterials and devices, providing a diagnostic tool for exotic properties of two-dimensional electron systems.

  2. A CMOS matrix for extracting MOSFET parameters before and after irradiation

    International Nuclear Information System (INIS)

    Blaes, B.R.; Buehler, M.G.; Lin, Y.S.; Hicks, K.A.

    1988-01-01

    An addressable matrix of 16 n- and 16 p-MOSFETs has been designed to extract the DC MOSFET parameters for all dc gate bias conditions before and after irradiation. The matrix contains four sets of MOSFETs each with four different geometries that can be biased independently before and after irradiation. Thus the worst-case bias scenarios can be determined. The MOSFET matrix was fabricated at a silicon foundry using a radiation-soft CMOS p-well LOCOS process. Cobalt 60 irradiation results for the n-MOSFETs showed a very low threshold voltage shift of -3mV/krad(Si); whereas, the p-MOSFETs showed 21 mV/krad(Si). The worst-case threshold voltage shift occurred for the n-MOSFET with a gate bias of 5V during anneal, but for the p-MOSFETs, biasing did not affect the shift in the threshold voltage. A parasitic MOSFET dominated the leakage of the n-MOSFET biased with 5V on the gate during irradiation

  3. Modeling and Extraction of Parameters Based on Physical Effects in Bipolar Transistors

    Directory of Open Access Journals (Sweden)

    Agnes Nagy

    2011-01-01

    Full Text Available The rising complexity of electronic systems, the reduction of components size, and the increment of working frequencies demand every time more accurate and stable integrated circuits, which require more precise simulation programs during the design process. PSPICE, widely used to simulate the general behavior of integrated circuits, does not consider many of the physical effects that can be found in real devices. Compact models, HICUM and MEXTRAM, have been developed over recent decades, in order to eliminate this deficiency. This paper presents some of the physical aspects that have not been studied so far, such as the expression of base-emitter voltage, including the emitter emission coefficient effect (n, physical explanation and simulation procedure, as well as a new extraction method for the diffusion potential VDE(T, based on the forward biased base-emitter capacitance, showing excellent agreement between experimental and theoretical results.

  4. Coconut oil extraction by the traditional Java method : An investigation of its potential application in aqueous Jatropha oil extraction

    NARCIS (Netherlands)

    Marasabessy, Ahmad; Moeis, Maelita R.; Sanders, Johan P. M.; Weusthuis, Ruud A.

    A traditional Java method of coconut oil extraction assisted by paddy crabs was investigated to find out if crabs or crab-derived components can be used to extract oil from Jatropha curcas seed kernels. Using the traditional Java method the addition of crab paste liberated 54% w w(-1) oil from

  5. Coconut oil extraction by the Java method: An investigation of its potential application in aqueous Jatropha oil extraction

    NARCIS (Netherlands)

    Marasabessy, A.; Moeis, M.R.; Sanders, J.P.M.; Weusthuis, R.A.

    2010-01-01

    A traditional Java method of coconut oil extraction assisted by paddy crabs was investigated to find out if crabs or crab-derived components can be used to extract oil from Jatropha curcas seed kernels. Using the traditional Java method the addition of crab paste liberated 54% w w-1 oil from grated

  6. Chemical Profiling of Acalypha Indica Obtained from Supercritical Carbon Dioxide Extraction and Soxhlet Extraction Methods

    OpenAIRE

    Surangkana Chaichoowong; Jan Bernd Bol; Pornprapa Bol; Thomas Gamse; Malinee Sriariyanun

    2017-01-01

    Acalypha indica is a weed that grows in South-East Asia. It contains several valuable compounds that can be used for curing various diseases such as rheumatism, skin infection and blood dysentery. Here, the extraction of A. indica using Soxhlet extraction with two different solvents and supercritical CO2 extraction (SCE) with two different temperatures (40 and 60°C) was performed. In Soxhlet extraction, ethanol solvent provided the highest extraction yield of 34.36%. For SCE, the increased te...

  7. DNA extraction on bio-chip: history and preeminence over conventional and solid-phase extraction methods.

    Science.gov (United States)

    Ayoib, Adilah; Hashim, Uda; Gopinath, Subash C B; Md Arshad, M K

    2017-11-01

    This review covers a developmental progression on early to modern taxonomy at cellular level following the advent of electron microscopy and the advancement in deoxyribonucleic acid (DNA) extraction for expatiation of biological classification at DNA level. Here, we discuss the fundamental values of conventional chemical methods of DNA extraction using liquid/liquid extraction (LLE) followed by development of solid-phase extraction (SPE) methods, as well as recent advances in microfluidics device-based system for DNA extraction on-chip. We also discuss the importance of DNA extraction as well as the advantages over conventional chemical methods, and how Lab-on-a-Chip (LOC) system plays a crucial role for the future achievements.

  8. Efficient Statistical Extraction of the Per-Unit-Length Capacitance and Inductance Matrices of Cables with Random Parameters

    Directory of Open Access Journals (Sweden)

    P. Manfredi

    2015-05-01

    Full Text Available Cable bundles often exhibit random parameter variations due to uncertain or uncontrollable physical properties and wire positioning. Efficient tools, based on the so-called polynomial chaos, exist to rapidly assess the impact of such variations on the per-unit-length capacitance and inductance matrices, and on the pertinent cable response. Nevertheless, the state-of-the-art method for the statistical extraction of the per-unit-length capacitance and inductance matrices of cables suffers from several inefficiencies that hinder its applicability to large problems, in terms of number of random parameters and/or conductors. This paper presents an improved methodology that overcomes the aforementioned limitations by exploiting a recently-published, alternative approach to generate the pertinent polynomial chaos system of equations. A sparse and decoupled system is obtained that provides remarkable benefits in terms of speed, memory consumption and problem size that can be dealt with. The technique is thoroughly validated through the statistical analysis of two canonical structures, i.e. a ribbon cable and a shielded cable with random geometry and position.

  9. Alternative and Efficient Extraction Methods for Marine-Derived Compounds

    Directory of Open Access Journals (Sweden)

    Clara Grosso

    2015-05-01

    Full Text Available Marine ecosystems cover more than 70% of the globe’s surface. These habitats are occupied by a great diversity of marine organisms that produce highly structural diverse metabolites as a defense mechanism. In the last decades, these metabolites have been extracted and isolated in order to test them in different bioassays and assess their potential to fight human diseases. Since traditional extraction techniques are both solvent- and time-consuming, this review emphasizes alternative extraction techniques, such as supercritical fluid extraction, pressurized solvent extraction, microwave-assisted extraction, ultrasound-assisted extraction, pulsed electric field-assisted extraction, enzyme-assisted extraction, and extraction with switchable solvents and ionic liquids, applied in the search for marine compounds. Only studies published in the 21st century are considered.

  10. GPR Signal Denoising and Target Extraction With the CEEMD Method

    KAUST Repository

    Li, Jing

    2015-04-17

    In this letter, we apply a time and frequency analysis method based on the complete ensemble empirical mode decomposition (CEEMD) method in ground-penetrating radar (GPR) signal processing. It decomposes the GPR signal into a sum of oscillatory components, with guaranteed positive and smoothly varying instantaneous frequencies. The key idea of this method relies on averaging the modes obtained by empirical mode decomposition (EMD) applied to several realizations of Gaussian white noise added to the original signal. It can solve the mode-mixing problem in the EMD method and improve the resolution of ensemble EMD (EEMD) when the signal has a low signal-to-noise ratio. First, we analyze the difference between the basic theory of EMD, EEMD, and CEEMD. Then, we compare the time and frequency analysis with Hilbert-Huang transform to test the results of different methods. The synthetic and real GPR data demonstrate that CEEMD promises higher spectral-spatial resolution than the other two EMD methods in GPR signal denoising and target extraction. Its decomposition is complete, with a numerically negligible error.

  11. A Review of Distributed Parameter Groundwater Management Modeling Methods

    Science.gov (United States)

    Gorelick, Steven M.

    1983-04-01

    Models which solve the governing groundwater flow or solute transport equations in conjunction with optimization techniques, such as linear and quadratic programing, are powerful aquifer management tools. Groundwater management models fall in two general categories: hydraulics or policy evaluation and water allocation. Groundwater hydraulic management models enable the determination of optimal locations and pumping rates of numerous wells under a variety of restrictions placed upon local drawdown, hydraulic gradients, and water production targets. Groundwater policy evaluation and allocation models can be used to study the influence upon regional groundwater use of institutional policies such as taxes and quotas. Furthermore, fairly complex groundwater-surface water allocation problems can be handled using system decomposition and multilevel optimization. Experience from the few real world applications of groundwater optimization-management techniques is summarized. Classified separately are methods for groundwater quality management aimed at optimal waste disposal in the subsurface. This classification is composed of steady state and transient management models that determine disposal patterns in such a way that water quality is protected at supply locations. Classes of research missing from the literature are groundwater quality management models involving nonlinear constraints, models which join groundwater hydraulic and quality simulations with political-economic management considerations, and management models that include parameter uncertainty.

  12. Highly efficient DNA extraction method from skeletal remains

    Directory of Open Access Journals (Sweden)

    Irena Zupanič Pajnič

    2011-03-01

    Full Text Available Background: This paper precisely describes the method of DNA extraction developed to acquire high quality DNA from the Second World War skeletal remains. The same method is also used for molecular genetic identification of unknown decomposed bodies in routine forensic casework where only bones and teeth are suitable for DNA typing. We analysed 109 bones and two teeth from WWII mass graves in Slovenia. Methods: We cleaned the bones and teeth, removed surface contaminants and ground the bones into powder, using liquid nitrogen . Prior to isolating the DNA in parallel using the BioRobot EZ1 (Qiagen, the powder was decalcified for three days. The nuclear DNA of the samples were quantified by real-time PCR method. We acquired autosomal genetic profiles and Y-chromosome haplotypes of the bones and teeth with PCR amplification of microsatellites, and mtDNA haplotypes 99. For the purpose of traceability in the event of contamination, we prepared elimination data bases including genetic profiles of the nuclear and mtDNA of all persons who have been in touch with the skeletal remains in any way. Results: We extracted up to 55 ng DNA/g of the teeth, up to 100 ng DNA/g of the femurs, up to 30 ng DNA/g of the tibias and up to 0.5 ng DNA/g of the humerus. The typing of autosomal and YSTR loci was successful in all of the teeth, in 98 % dekalof the femurs, and in 75 % to 81 % of the tibias and humerus. The typing of mtDNA was successful in all of the teeth, and in 96 % to 98 % of the bones. Conclusions: We managed to obtain nuclear DNA for successful STR typing from skeletal remains that were over 60 years old . The method of DNA extraction described here has proved to be highly efficient. We obtained 0.8 to 100 ng DNA/g of teeth or bones and complete genetic profiles of autosomal DNA, Y-STR haplotypes, and mtDNA haplotypes from only 0.5g bone and teeth samples.

  13. A method to extract soil water for stable isotope analysis

    Science.gov (United States)

    Revesz, Kinga; Woods, Peter H.

    1990-07-01

    A method has been developed to extract soil water for determination of deuterium (D) and 18O content. The principle of this method is based on the observation that water and toluene form an azeotropic mixture at 84.1°C, but are completely immiscible at ambient temperature. In a specially designed distillation apparatus, the soil water is distilled at 84.1°C with toluene and is separated quantitatively in the collecting funnel at ambient temperature. Traces of toluene are removed and the sample can be analyzed by mass spectrometry. Kerosene may be substituted for toluene. The accuracy of this technique is ± 2 and ± 0.2‰, respectively, for δD and δ 18O. Reduced accuracy is obtained at low water contents.

  14. The influence of temperature and time on the stability of the antioxidant activity and colour parameters of grape marc ethanolic extract

    Directory of Open Access Journals (Sweden)

    Elena CRISTEA

    2015-12-01

    Full Text Available The interest to replace synthetic food colorants, preservatives and antioxidants in beverages with natural ones is leading researchers to explore the polyphenols of winery wastes. It is of great interest to see if these compounds could replace synthetic dyes in drinks. However, it is still necessary to study the stability of extracts containing grape phenolics during various technological treatments. This paper presents the study of the stability of the 50% ethanolic extract of marc resulting from the winemaking process. The extract was subjected to the following temperatures: -2oC for 12 hours; 4oC for 12 hours; 40oC for 15 minutes, 60oC for 15 minutes, 80oC for 15 minutes and 100oC for 2 minutes; after that the antioxidant activity and the colour parameters (CIELab were measured. Three sets of extracts were kept for 2 weeks at -2oC, 4oC, and 25-30oC and afterwards the parameters mentioned above were measured once again. Furthermore, the total content of polyphenols and the content of tannins were determined using the Folin-Ciocalteu method. The results were expressed in mg gallic acid equivalents per litre and mg tannic acid equivalents per litre, respectively. The antioxidant activity was determined using the method based on the interaction with the ABTS radical, the results being expressed in % inhibition. The results have shown that the colour (CIELab parameters and the antioxidant activity of the ethanolic extract of marc are relatively stable during thermal processes. High temperatures as well as prolonged storage at room temperature increased the values of antioxidant activity, chroma, and redness. However, they also produced the most significant effect of the overall colour of the extract, leading to the degradation of blue pigments and a shift towards orange hues.

  15. Study on Process Parameters of Extraction of γ-aminobutyric Acid Instant Moringa oleifera Powder

    Science.gov (United States)

    Tiaokun, Fu; Suhui, Zhang; Neng, Liu; Jihua, Li; Shaodan, Peng; Changqing, Guo; Wei, Zhou

    2017-12-01

    To preliminary optimize the extraction of γ-aminobutyric acid instant tea powder from Moringa oleifera leaves,taking γ-aminobutyric acid Moringa oleifera leaves as raw material and pure water as extraction solvent and GABA content as the main evaluation index,the effects of extraction temperature, ratio of liquid to material and extraction time on biochemical components and sensory qualities of Moringa oleifera leaves extractor was studied by using one-factor-at-a-time experiment.The results showed shat the optimal extraction conditions for γ-aminobutyric acid instant tea powder were extraction temperature of 60 °C, material-to-water ration of 1:10 and extraction time of 40 min.

  16. Optimization of processing parameters for extraction of essential oil from Foeniculum vulgare

    Directory of Open Access Journals (Sweden)

    2017-11-01

    Full Text Available Background and objectives: It is necessary to specify the best conditions of essential oils production to get more major compound(s and higher yield oil. The fennel oil is useful in pharmaceutical industry as flavor. The main component of fennel oil is anethole (55-75%. The objective of this work was to identify the effect of  particle size, pH of water, method of distillation and using ultrasound on extraction of fennel essential oil (and its major constituent, anethole. Methods: We used a statistical method called D-optimal Design that appointed pH, particle size and method for each assay. Fennel seeds were purchased, then milled and passed from different meshes. In the first series, the seeds powder was distilled directly. In the second series the seeds were placed in an ultrasonic apparatus for 30 min. The essential oils were subsequently isolated by two methods, hydro distillation and steam distillation, in different sizes (25, 30, 40, 50 and pH (5.5, 5.8, 7, 7.4, 8.5. Fifty g of dry seeds were used in each distillation (for 3 h. Analytical gas chromatography (GC was used to determine the essential oil composition. Results: In the steam distillation, the volume of essential oils and the concentration of anethole, whatever the plant became smaller, was less. However, in the water distillation, it was more and by comparing the two steps, without and with ultrasound, it increased 20% after the ultrasound. Conclusion: optimum conditions according to the statistical results were steam distillation, mesh size 50 and using ultrasounic device.

  17. A New Method for Weak Fault Feature Extraction Based on Improved MED

    Directory of Open Access Journals (Sweden)

    Junlin Li

    2018-01-01

    Full Text Available Because of the characteristics of weak signal and strong noise, the low-speed vibration signal fault feature extraction has been a hot spot and difficult problem in the field of equipment fault diagnosis. Moreover, the traditional minimum entropy deconvolution (MED method has been proved to be used to detect such fault signals. The MED uses objective function method to design the filter coefficient, and the appropriate threshold value should be set in the calculation process to achieve the optimal iteration effect. It should be pointed out that the improper setting of the threshold will cause the target function to be recalculated, and the resulting error will eventually affect the distortion of the target function in the background of strong noise. This paper presents an improved MED based method of fault feature extraction from rolling bearing vibration signals that originate in high noise environments. The method uses the shuffled frog leaping algorithm (SFLA, finds the set of optimal filter coefficients, and eventually avoids the artificial error influence of selecting threshold parameter. Therefore, the fault bearing under the two rotating speeds of 60 rpm and 70 rpm is selected for verification with typical low-speed fault bearing as the research object; the results show that SFLA-MED extracts more obvious bearings and has a higher signal-to-noise ratio than the prior MED method.

  18. Multiple-Fault Diagnosis Method Based on Multiscale Feature Extraction and MSVM_PPA

    Directory of Open Access Journals (Sweden)

    Min Zhang

    2018-01-01

    Full Text Available Identification of rolling bearing fault patterns, especially for the compound faults, has attracted notable attention and is still a challenge in fault diagnosis. In this paper, a novel method called multiscale feature extraction (MFE and multiclass support vector machine (MSVM with particle parameter adaptive (PPA is proposed. MFE is used to preprocess the process signals, which decomposes the data into intrinsic mode function by empirical mode decomposition method, and instantaneous frequency of decomposed components was obtained by Hilbert transformation. Then, statistical features and principal component analysis are utilized to extract significant information from the features, to get effective data from multiple faults. MSVM method with PPA parameters optimization will classify the fault patterns. The results of a case study of the rolling bearings faults data from Case Western Reserve University show that (1 the proposed intelligent method (MFE_PPA_MSVM improves the classification recognition rate; (2 the accuracy will decline when the number of fault patterns increases; (3 prediction accuracy can be the best when the training set size is increased to 70% of the total sample set. It verifies the method is feasible and efficient for fault diagnosis.

  19. Influence of mixing and extraction parameters on virgin olive oil quality

    Directory of Open Access Journals (Sweden)

    Pasqualone, A.

    2001-08-01

    Full Text Available The mixing time, the temperature and the degree of dilution of olive paste are the main parameters liable to change during mixing and oil ext raction. They can greatly differ from a processing run to another, with variations being observed in Tuscan oil mills, between 26ºC and 36ºC, 40’ and 90’, and 10% and 50% respectively, for the temperature, the mixing time and the water added during the centrifugal extraction. This note reports on the results of some experimental trials run during the 1998 olive oil year in Tuscany. The mixing time and temperature as well as the olive paste dilution were changed one at a time and were assessed for their influence on extraction yield and oil quality. The best conditions to optimise the product yield and quality were identified.El tiempo de batido, la temperatura y el grado de dilución de la pasta de aceituna, son los principales parámetros que pueden sufrir cambios durante el batido y la extracción del aceite. Estos pueden diferir mucho de un proceso a otro, habiendo sido observadas variaciones en los aceites de molino de Toscana, entre 26ºC y 36ºC, 40’ y 90’, y 10% y 50% respectivamente, para la temperatura, el tiempo de batido y el agua añadida durante la extracción por centrifugación. Este artículo presenta los resultados de algunos ensayos experimentales realizados durante el año 1998 con aceite de oliva de Toscana. El tiempo de batido y la temperatura, así como la dilución de la pasta de aceitunas, se variaron uno a uno y se evaluaron por su influencia en el rendimiento de la extracción y la calidad del aceite. Las mejores condiciones para optimizar el rendimiento y la calidad del producto fueron identificadas.

  20. Optimization of two methods based on ultrasound energy as alternative to European standards for soluble salts extraction from building materials.

    Science.gov (United States)

    Prieto-Taboada, N; Gómez-Laserna, O; Martinez-Arkarazo, I; Olazabal, M A; Madariaga, J M

    2012-11-01

    The Italian recommendation NORMAL 13/83, later replaced by the UNI 11087/2003 norm, were used as standard for soluble salts extraction from construction materials. These standards are based on long-time stirring (72 and 2h, respectively) of the sample in deionized water. In this work two ultrasound based methods were optimized in order to reduce the extraction time while efficiency is improved. The instrumental variables involved in the extraction assisted by ultrasound bath and focused ultrasounds were optimized by experimental design. As long as it was possible, the same non-instrumental parameters values as those of standard methods were used in order to compare the results obtained on a mortar sample showing a black crust by the standards and the optimized methods. The optimal extraction time for the ultrasounds bath was found to be of two hours. Although the extraction time was equal to the standard UNI 11087/2003, the obtained extraction recovery was improved up to 119%. The focused ultrasound system achieved also better recoveries (up to 106%) depending on the analyte in 1h treatment time. The repeatabilities of the proposed ultrasound based methods were comparables to those of the standards. Therefore, the selection of one or the other of the ultrasound based methods will depend on topics such as laboratory facilities or number of samples, and not in aspects related with their quality parameters. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. A new extraction method of loess shoulder-line based on Marr-Hildreth operator and terrain mask.

    Directory of Open Access Journals (Sweden)

    Sheng Jiang

    Full Text Available Loess shoulder-lines are significant structural lines which divide the complicated loess landform into loess interfluves and gully-slope lands. Existing extraction algorithms for shoulder-lines mainly are based on local maximum of terrain features. These algorithms are sensitive to noise for complicated loess surface and the extraction parameters are difficult to be determined, making the extraction results usually inaccurate. This paper presents a new extraction approach for loess shoulder-lines, in which Marr-Hildreth edge operator is employed to construct initial shoulder-lines. Then the terrain mask for confining the boundary of shoulder-lines is proposed based on slope degree classification and morphology methods, avoiding interference from non-valley area and modify the initial loess shoulder-lines. A case study is conducted in Yijun located in the northern Shanxi Loess Plateau of China. The Digital Elevation Models with a grid size of 5 m is applied as original data. To obtain optimal scale parameters, the Euclidean Distance Offset Percentages between shoulder-lines is calculated by the Marr-Hildreth operator and the manual delineations. The experimental results show that the new method could achieve the highest extraction accuracy when σ = 5 in Gaussian smoothing. According to the accuracy assessment, the average extraction accuracy is about 88.5%, which indicates that the proposed method is applicable for the extraction of loess shoulder-lines in the loess hilly and gully areas.

  2. Soil parameters are key factors to predict metal bioavailability to snails based on chemical extractant data

    International Nuclear Information System (INIS)

    Pauget, B.; Gimbert, F.; Scheifler, R.; Coeurdassier, M.; Vaufleury, A. de

    2012-01-01

    assessing accumulation kinetics. ► EDTA extracts and total soil concentration allows the assessment of bioavailability to snails for Cd and Pb, respectively. ► No chemical method allows the assessment of Zn bioavailability to snails. ► Total soil concentration coupled with soil characteristics allow Cd, Pb and Zn bioavailability to snails to be predicted.

  3. Soil parameters are key factors to predict metal bioavailability to snails based on chemical extractant data

    Energy Technology Data Exchange (ETDEWEB)

    Pauget, B.; Gimbert, F., E-mail: frederic.gimbert@univ-fcomte.fr; Scheifler, R.; Coeurdassier, M.; Vaufleury, A. de

    2012-08-01

    to snails. Black-Right-Pointing-Pointer Bioavailability of cadmium, lead and zinc to snails was determined by assessing accumulation kinetics. Black-Right-Pointing-Pointer EDTA extracts and total soil concentration allows the assessment of bioavailability to snails for Cd and Pb, respectively. Black-Right-Pointing-Pointer No chemical method allows the assessment of Zn bioavailability to snails. Black-Right-Pointing-Pointer Total soil concentration coupled with soil characteristics allow Cd, Pb and Zn bioavailability to snails to be predicted.

  4. How far away is far enough for extracting numerical waveforms, and how much do they depend on the extraction method?

    Energy Technology Data Exchange (ETDEWEB)

    Pazos, Enrique [Department of Physics and Astronomy, 202 Nicholson Hall, Louisiana State University, Baton Rouge, LA 70803 (United States); Dorband, Ernst Nils [Department of Physics and Astronomy, 202 Nicholson Hall, Louisiana State University, Baton Rouge, LA 70803 (United States); Nagar, Alessandro [Dipartimento di Fisica, Politecnico di Torino, Corso Duca Degli Abruzzi 24, 10129 Torino (Italy); Palenzuela, Carlos [Department of Physics and Astronomy, 202 Nicholson Hall, Louisiana State University, Baton Rouge, LA 70803 (United States); Schnetter, Erik [Center for Computation and Technology, 216 Johnston Hall, Louisiana State University, Baton Rouge, LA 70803 (United States); Tiglio, Manuel [Department of Physics and Astronomy, 202 Nicholson Hall, Louisiana State University, Baton Rouge, LA 70803 (United States)

    2007-06-21

    We present a method for extracting gravitational waves from numerical spacetimes which generalizes and refines one of the standard methods based on the Regge-Wheeler-Zerilli perturbation formalism. At the analytical level, this generalization allows a much more general class of slicing conditions for the background geometry, and is thus not restricted to Schwarzschild-like coordinates. At the numerical level, our approach uses high-order multi-block methods, which improve both the accuracy of our simulations and of our extraction procedure. In particular, the latter is simplified since there is no need for interpolation, and we can afford to extract accurate waves at large radii with only little additional computational effort. We then present fully nonlinear three-dimensional numerical evolutions of a distorted Schwarzschild black hole in Kerr-Schild coordinates with an odd parity perturbation and analyse the improvement that we gain from our generalized wave extraction, comparing our new method to the standard one. In particular, we analyse in detail the quasinormal frequencies of the extracted waves, using both methods. We do so by comparing the extracted waves with one-dimensional high resolution solutions of the corresponding generalized Regge-Wheeler equation. We explicitly see that the errors in the waveforms extracted with the standard method at fixed, finite extraction radii do not converge to zero with increasing resolution. We find that even with observers as far out as R = 80M-which is larger than what is commonly used in state-of-the-art simulations-the assumption in the standard method that the background is close to having Schwarzschild-like coordinates increases the error in the extracted waves considerably. Furthermore, those errors are dominated by the extraction method itself and not by the accuracy of our simulations. For extraction radii between 20M and 80M and for the resolutions that we use in this paper, our new method decreases the errors

  5. How far away is far enough for extracting numerical waveforms, and how much do they depend on the extraction method?

    International Nuclear Information System (INIS)

    Pazos, Enrique; Dorband, Ernst Nils; Nagar, Alessandro; Palenzuela, Carlos; Schnetter, Erik; Tiglio, Manuel

    2007-01-01

    We present a method for extracting gravitational waves from numerical spacetimes which generalizes and refines one of the standard methods based on the Regge-Wheeler-Zerilli perturbation formalism. At the analytical level, this generalization allows a much more general class of slicing conditions for the background geometry, and is thus not restricted to Schwarzschild-like coordinates. At the numerical level, our approach uses high-order multi-block methods, which improve both the accuracy of our simulations and of our extraction procedure. In particular, the latter is simplified since there is no need for interpolation, and we can afford to extract accurate waves at large radii with only little additional computational effort. We then present fully nonlinear three-dimensional numerical evolutions of a distorted Schwarzschild black hole in Kerr-Schild coordinates with an odd parity perturbation and analyse the improvement that we gain from our generalized wave extraction, comparing our new method to the standard one. In particular, we analyse in detail the quasinormal frequencies of the extracted waves, using both methods. We do so by comparing the extracted waves with one-dimensional high resolution solutions of the corresponding generalized Regge-Wheeler equation. We explicitly see that the errors in the waveforms extracted with the standard method at fixed, finite extraction radii do not converge to zero with increasing resolution. We find that even with observers as far out as R = 80M-which is larger than what is commonly used in state-of-the-art simulations-the assumption in the standard method that the background is close to having Schwarzschild-like coordinates increases the error in the extracted waves considerably. Furthermore, those errors are dominated by the extraction method itself and not by the accuracy of our simulations. For extraction radii between 20M and 80M and for the resolutions that we use in this paper, our new method decreases the errors

  6. Influence of different extraction methods on the yield and linalool content of the extracts of Eugenia uniflora L.

    Science.gov (United States)

    Galhiane, Mário S; Rissato, Sandra R; Chierice, Gilberto O; Almeida, Marcos V; Silva, Letícia C

    2006-09-15

    This work has been developed using a sylvestral fruit tree, native to the Brazilian forest, the Eugenia uniflora L., one of the Mirtaceae family. The main goal of the analytical study was focused on extraction methods themselves. The method development pointed to the Clevenger extraction as the best yield in relation to SFE and Soxhlet. The SFE method presented a good yield but showed a big amount of components in the final extract, demonstrating low selectivity. The essential oil extracted was analyzed by GC/FID showing a large range of polarity and boiling point compounds, where linalool, a widely used compound, was identified. Furthermore, an analytical solid phase extraction method was used to clean it up and obtain separated classes of compounds that were fractionated and studied by GC/FID and GC/MS.

  7. Basic Test Framework for the Evaluation of Text Line Segmentation and Text Parameter Extraction

    Directory of Open Access Journals (Sweden)

    Darko Brodić

    2010-05-01

    Full Text Available Text line segmentation is an essential stage in off-line optical character recognition (OCR systems. It is a key because inaccurately segmented text lines will lead to OCR failure. Text line segmentation of handwritten documents is a complex and diverse problem, complicated by the nature of handwriting. Hence, text line segmentation is a leading challenge in handwritten document image processing. Due to inconsistencies in measurement and evaluation of text segmentation algorithm quality, some basic set of measurement methods is required. Currently, there is no commonly accepted one and all algorithm evaluation is custom oriented. In this paper, a basic test framework for the evaluation of text feature extraction algorithms is proposed. This test framework consists of a few experiments primarily linked to text line segmentation, skew rate and reference text line evaluation. Although they are mutually independent, the results obtained are strongly cross linked. In the end, its suitability for different types of letters and languages as well as its adaptability are its main advantages. Thus, the paper presents an efficient evaluation method for text analysis algorithms.

  8. Comparison of clinical parameters and environmental noise levels between regular surgery and piezosurgery for extraction of impacted third molars.

    Science.gov (United States)

    Chang, Hao-Hueng; Lee, Ming-Shu; Hsu, You-Chyun; Tsai, Shang-Jye; Lin, Chun-Pin

    2015-10-01

    Impacted third molars can be extracted by regular surgery or piezosurgery. The aim of this study was to compare clinical parameters and device-produced noise levels between regular surgery and piezosurgery for the extraction of impacted third molars. Twenty patients (18 women and 2 men, 17-29 years of age) with bilateral symmetrical impacted mandibular or maxillary third molars of the same level were included in this randomized crossover clinical trial. The 40 impacted third molars were divided into a control group (n = 20), in which the third molar was extracted by regular surgery using a high-speed handpiece and an elevator, and an experimental group (n = 20), in which the third molar was extracted by piezosurgery using a high-speed handpiece and a piezotome. The clinical parameters were evaluated by a self-reported questionnaire. The noise levels produced by the high-speed handpiece and piezotome were measured and compared between the experimental and control groups. Patients in the experimental group had a better feeling about tooth extraction and force delivery during extraction and less facial swelling than patients in the control group. However, there were no significant differences in noise-related disturbance, extraction period, degree of facial swelling, pain score, pain duration, any noise levels produced by the devices under different circumstances during tooth extraction between the control and experimental groups. The piezosurgery device produced noise levels similar to or lower than those of the high-speed drilling device. However, piezosurgery provides advantages of increased patient comfort during extraction of impacted third molars. Copyright © 2014. Published by Elsevier B.V.

  9. Comparison of different extraction methods for giberelic acid obtention from corn (Zea mays L. germinated seeds

    Directory of Open Access Journals (Sweden)

    Juan David Rivera

    2017-05-01

    Full Text Available Corn (Zea mays L. is the second most cultivated cereal in the world and is use as raw material for different kind of industries. To date no reports about obtaining giberellic acid (GA3 from corn have been found. In the present study two methods for extracting solid samples were evaluated: lixiviation and dynamic sonication-assisted solvent extraction (DSASE, for obtaining giberellic acid from corn germinated seeds. In lixiviation, the physical method (agitation and sonication, solvent, and time were the parameters analyzed; while in DSASE the variables were: solvent, flow, and time. The most efficient technique was DSASE employing acetonitrile-formic acid 5% (80:20, v:v as solvent at a flow of 0.4 mL/min for 25,0 min, obtaining a concentration 30.012 mg/kg giberellic acid. The identification and quantification were performed by high performance liquid chromatography (HPLC with diode array detector (DAD. These results showed that dynamic sonication-assisted solvent extraction (DSASE is a novel and powerful alternative technique for obtaining giberellic acid, because of its high efficiency; low solvent consumption and simplicity in obtaining the extract.

  10. Anomalies in the Fujikawa method using parameter-dependent regulators

    International Nuclear Information System (INIS)

    Urrutia, L.F.; Vergara, J.D.

    1992-01-01

    We propose an extended definition of the regularized Jacobian which allows the calculation of anomalies using parameter-dependent regulators in the Fujikawa approach. This extension incorporates the basic Green's function of the problem in the regularized Jacobian, allowing us to interpret a specific regularization procedure as a way of selecting the finite part of the Green's function, in complete analogy with what is done at the level of the effective action. In this way we are able to consider the effect of counterterms in the regularized Jacobian in order to relate different regularization procedures. We also discuss the ambiguities that arise in our prescription due to some freedom in the place where we can insert the regulator, using charge-conjugation invariance as a guiding principle. The method is applied to the case of vector and axial-vector anomalies in two- and four-dimensional quantum electrodynamics. In the first situation we recover the standard family of anomalies calculated by the point-splitting regularization prescription. We also study in detail an alternative choice in the position of the regulator and we calculate explicitly all the currents that generate the families of anomalies that we are considering. Next we extend the calculation to four dimensions, using the same prescriptions as before, and we compare the results with those obtained from the point-splitting calculation, which we also perform in the case of the vector anomaly. A discussion of the relation among the results obtained by different regularization prescriptions is given in terms of the allowed counterterms in the regularized Jacobian, which are highly constrained by the requirement of charge-conjugation invariance

  11. Activation method for measurement of neutron spectrum parameters

    International Nuclear Information System (INIS)

    Efimov, B.V.; Demidov, A.M.; Ionov, V.S.; Konjaev, S.I.; Marin, S.V.; Bryzgalov, V.I.

    2007-01-01

    Experimental researches of spectrum parameters of neutrons at nuclear installations RRC KI are submitted. The installations have different designs of the cores, reflector, parameters and types of fuel elements. Measurements were carried out with use of the technique developed in RRC KI for irradiation resonance detectors UKD. The arrangement of detectors in the cores ensured possibility of measurement of neutron spectra with distinguished values of parameters. The spectrum parameters which are introduced by parametrical representation of a neutrons spectrum in the form corresponding to formalism Westcott. On experimental data were determinate absolute values of density neutron flux (DNF) in thermal and epithermal area of a spectrum (F t , f epi ), empirical dependence of temperature of neutron gas (Tn) on parameter of a rigidity of a spectrum (z), density neutron flux in transitional energy area of the spectrum. Dependences of spectral indexes of nuclides (UDy/UX), included in UKD, from a rigidity z and-or temperatures of neutron gas Tn are obtained.B Tools of mathematical processing of results are used for activation data and estimation of parameters of a spectrum (F t , f epi , z, Tn, UDy/UX). In the paper are presented some results of researches of neutron spectrum parameters of the nuclear installations (Authors)

  12. Polyphenols: Extraction Methods, Antioxidative Action, Bioavailability and Anticarcinogenic Effects

    Directory of Open Access Journals (Sweden)

    Eva Brglez Mojzer

    2016-07-01

    Full Text Available Being secondary plant metabolites, polyphenols represent a large and diverse group of substances abundantly present in a majority of fruits, herbs and vegetables. The current contribution is focused on their bioavailability, antioxidative and anticarcinogenic properties. An overview of extraction methods is also given, with supercritical fluid extraction highlighted as a promising eco-friendly alternative providing exceptional separation and protection from degradation of unstable polyphenols. The protective role of polyphenols against reactive oxygen and nitrogen species, UV light, plant pathogens, parasites and predators results in several beneficial biological activities giving rise to prophylaxis or possibly even to a cure for several prevailing human diseases, especially various cancer types. Omnipresence, specificity of the response and the absence of or low toxicity are crucial advantages of polyphenols as anticancer agents. The main problem represents their low bioavailability and rapid metabolism. One of the promising solutions lies in nanoformulation of polyphenols that prevents their degradation and thus enables significantly higher concentrations to reach the target cells. Another, more practiced, solution is the use of mixtures of various polyphenols that bring synergistic effects, resulting in lowering of the required therapeutic dose and in multitargeted action. The combination of polyphenols with existing drugs and therapies also shows promising results and significantly reduces their toxicity.

  13. A window-based time series feature extraction method.

    Science.gov (United States)

    Katircioglu-Öztürk, Deniz; Güvenir, H Altay; Ravens, Ursula; Baykal, Nazife

    2017-10-01

    This study proposes a robust similarity score-based time series feature extraction method that is termed as Window-based Time series Feature ExtraCtion (WTC). Specifically, WTC generates domain-interpretable results and involves significantly low computational complexity thereby rendering itself useful for densely sampled and populated time series datasets. In this study, WTC is applied to a proprietary action potential (AP) time series dataset on human cardiomyocytes and three precordial leads from a publicly available electrocardiogram (ECG) dataset. This is followed by comparing WTC in terms of predictive accuracy and computational complexity with shapelet transform and fast shapelet transform (which constitutes an accelerated variant of the shapelet transform). The results indicate that WTC achieves a slightly higher classification performance with significantly lower execution time when compared to its shapelet-based alternatives. With respect to its interpretable features, WTC has a potential to enable medical experts to explore definitive common trends in novel datasets. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Carbon extraction methods for radiocarbon dating of pottery

    International Nuclear Information System (INIS)

    Delque-Kolic, E.

    1995-01-01

    Pottery is a direct witness of human activity and gives, through its macroscopic and microscopic studies, lots of information about its manufacturers. Nevertheless, radiocarbon dating, currently applied in archaeology to charcoals, wood and bones has only been rarely employed with ceramic. The problem is that many different carbon sources, of different radiocarbon age, may contribute to the potsherd carbon content. So, the aim of all dating projects is to separate carbon related to the period when the potsherd was manufactured and used. In a first time, we have made our own samples with raw materials (clay and temper) known in nature and age. We have fired them with wood of known age under reducing atmosphere. Under these conditions, soot produced by wood burning forms a more or less important deposit on the surface of the pots. It is this source of carbon, present in many archaeological sherds, that we first tried to select. Burning these potsherds at low temperature under an O 2 flow, we have noticed that carbon from kiln wood was preferentially extracted. This treatment applied to a thin lamella cut in a smoked part of the potsherd provides, almost exclusively, carbon from smoke. These techniques, applied to known archaeological sherds, have given encouraging results. We have also explored a new method which consists in oxidizing carbon with a laser beam at the surface of the sample. The use of this process for extracting carbon from smoke seems promising if serious experimental precautions are taken when working with so low carbon content. (author)

  15. Theoretical justification of space-mapping-based modeling utilizing a database and on-demand parameter extraction

    DEFF Research Database (Denmark)

    Koziel, Slawomir; Bandler, John W.; Madsen, Kaj

    2006-01-01

    the surrogate, we perform parameter extraction with weighting coefficients dependent on the distance between the point of interest and base points. We provide theoretical results showing that the new methodology can assure any accuracy that is required (provided the base set is dense enough), which...

  16. Detecting and extracting clusters in atom probe data: A simple, automated method using Voronoi cells

    International Nuclear Information System (INIS)

    Felfer, P.; Ceguerra, A.V.; Ringer, S.P.; Cairney, J.M.

    2015-01-01

    The analysis of the formation of clusters in solid solutions is one of the most common uses of atom probe tomography. Here, we present a method where we use the Voronoi tessellation of the solute atoms and its geometric dual, the Delaunay triangulation to test for spatial/chemical randomness of the solid solution as well as extracting the clusters themselves. We show how the parameters necessary for cluster extraction can be determined automatically, i.e. without user interaction, making it an ideal tool for the screening of datasets and the pre-filtering of structures for other spatial analysis techniques. Since the Voronoi volumes are closely related to atomic concentrations, the parameters resulting from this analysis can also be used for other concentration based methods such as iso-surfaces. - Highlights: • Cluster analysis of atom probe data can be significantly simplified by using the Voronoi cell volumes of the atomic distribution. • Concentration fields are defined on a single atomic basis using Voronoi cells. • All parameters for the analysis are determined by optimizing the separation probability of bulk atoms vs clustered atoms

  17. A SIMPLE METHOD FOR THE EXTRACTION AND QUANTIFICATION OF PHOTOPIGMENTS FROM SYMBIODINIUM SPP.

    Science.gov (United States)

    John E. Rogers and Dragoslav Marcovich. Submitted. Simple Method for the Extraction and Quantification of Photopigments from Symbiodinium spp.. Limnol. Oceanogr. Methods. 19 p. (ERL,GB 1192). We have developed a simple, mild extraction procedure using methanol which, when...

  18. Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method.

    Science.gov (United States)

    Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, Mahmoudreza; Karami-Osboo, Rouhollah

    2013-01-01

    Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase containing enriched analyte was dissolved in acetonitrile and an aliquot of this solution injected into the HPLC system for analysis. Development of DLLME procedure includes optimization of some important parameters such as kind and volume of extraction and disperser solvent, pH and salt addition. The proposed method has good linearity in the range of 0.02-4.5 μg mL(-1) and low detection limit (13.1 ng mL(-1)). The repeatability of the method, expressed as relative standard deviation was 4.9% (n = 3). This method has also been applied to the analysis of real urine samples with satisfactory relative recoveries in the range of 91.6-101.0%.

  19. A novel parameter estimation method for metal oxide surge arrester ...

    Indian Academy of Sciences (India)

    the program, which is based on MAPSO algorithm and can determine the fitness and parameters .... to solve many optimization problems (Kennedy & Eberhart 1995; Eberhart & Shi 2001; Gaing. 2003 ... describe the content of this concept. V el.

  20. Iterative methods for distributed parameter estimation in parabolic PDE

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, C.R. [Montana State Univ., Bozeman, MT (United States); Wade, J.G. [Bowling Green State Univ., OH (United States)

    1994-12-31

    The goal of the work presented is the development of effective iterative techniques for large-scale inverse or parameter estimation problems. In this extended abstract, a detailed description of the mathematical framework in which the authors view these problem is presented, followed by an outline of the ideas and algorithms developed. Distributed parameter estimation problems often arise in mathematical modeling with partial differential equations. They can be viewed as inverse problems; the `forward problem` is that of using the fully specified model to predict the behavior of the system. The inverse or parameter estimation problem is: given the form of the model and some observed data from the system being modeled, determine the unknown parameters of the model. These problems are of great practical and mathematical interest, and the development of efficient computational algorithms is an active area of study.

  1. Extracting CKM phases and Bs-B-bars mixing parameters from angular distributions of non-leptonic B decays

    International Nuclear Information System (INIS)

    Dighe, A.S.; Dunietz, I.; Fleischer, R.

    1998-04-01

    Suggestions for efficiently determining the lifetimes and mass difference of the light and heavy B s mesons (B L s , B H s ) from B s →J/ψφ, D *+ s D *- s decays are given. Using appropriate weighting functions for the angular distributions of the decay products (moment analysis), one can extract (Γ H , Γ L , Δm) Bs . Such a moment analysis allows the determination of the relative magnitudes and phases of the CP-odd and CP-even decay amplitudes. Efficient determinations of CP-violating effects occurring in B s →J/ψφ, D *+ s D *- s are discussed in the light of a possible width difference (ΔΓ) Bs , and the utility of this method for B→J/ψK * , D *+ s D-bar * decays is noted. Since our approach is very general, it can in principle be applied to all kings of angular distributions and allows the determination of all relevant observables, including fundamental CKM (Cabibbo-Kobayashi-Maskawa) parameters, as well as tests of various aspects of the factorization hypothesis. Explicit angular distributions and weighting functions are given, and the general method that can be used for any angular distribution is indicated. (author)

  2. Optimizing design parameter for light isotopes separation by distillation method

    International Nuclear Information System (INIS)

    Ahmadi, M.

    1999-01-01

    More than methods are suggested in the world for producing heavy water, where between them chemical isotopic methods, distillation and electro lys are used widely in industrial scale. To select suitable method for heavy water production in Iran, taking into consideration, domestic technology an facilities, combination of hydrogen sulphide-water dual temperature process (Gs) and distillation (D W) may be proposed. Natural water, is firstly enriched up to 15 a% by G S process and then by distillation unit is enriched up to the grade necessary for Candu type reactors (99.8 a%). The aim of present thesis, is to achieve know-how, optimization of design parameters, and executing basic design for water isotopes separation using distillation process in a plant having minimum scale possible. In distillation, vapour phase resulted from liquid phase heating, is evidently composed of the same constituents as liquid phase. In isotopic distillation, the difference in composition of constituents is not considerable. In fact alteration of constituents composition is so small that makes the separation process impossible, however, direct separation and production of pure products without further processing which becomes possible by distillation, makes this process as one of the most important separation processes. Profiting distillation process to produce heavy water is based on difference existing between boiling point of heavy and light water. The trends of boiling points differences (heavy and light water) is adversely dependant with pressure. As the whole system pressure decreases, difference in boiling points increases. On the other hand according to the definition, separation factor is equal to the ratio of pure light water vapour pressure to that of heavy water, or we can say that the trend of whole system pressure decrease results in separation factor increase, which accordingly separation factor equation to pressure variable should be computed firstly. According to the

  3. The Effect of Homogenization Pressures on Extraction of Avocado Oil by Wet Method

    OpenAIRE

    Basuni Hamzah

    2013-01-01

    Avocado tree usually planted by people of Indonesia in rural are small in scale. Mostly, in the modern and high scale industry especially company has a large avocado farm the extraction of avocado oil is extracted through vacuum drying in low temperature. However, in rural area avocado tree spread out in small number of tree, so it needs alternative method of avocado oil extraction. In this experiment, wet method of avocado extraction was applied similar to traditional extraction of coconut o...

  4. Distant Supervision for Relation Extraction with Ranking-Based Methods

    Directory of Open Access Journals (Sweden)

    Yang Xiang

    2016-05-01

    Full Text Available Relation extraction has benefited from distant supervision in recent years with the development of natural language processing techniques and data explosion. However, distant supervision is still greatly limited by the quality of training data, due to its natural motivation for greatly reducing the heavy cost of data annotation. In this paper, we construct an architecture called MIML-sort (Multi-instance Multi-label Learning with Sorting Strategies, which is built on the famous MIML framework. Based on MIML-sort, we propose three ranking-based methods for sample selection with which we identify relation extractors from a subset of the training data. Experiments are set up on the KBP (Knowledge Base Propagation corpus, one of the benchmark datasets for distant supervision, which is large and noisy. Compared with previous work, the proposed methods produce considerably better results. Furthermore, the three methods together achieve the best F1 on the official testing set, with an optimal enhancement of F1 from 27.3% to 29.98%.

  5. Study of parameters affecting the extraction of Ytterbium from anomaly No.5 of Saghand ore Leach Solution

    International Nuclear Information System (INIS)

    Abdollahy, M.; Alamdar Milani, S.; Koleini, M. J.; Samadzadeh Yazdi, M. R.

    2010-01-01

    Extraction of ytterbium from anomaly No.5 of Saghand leach solution using D 2 EHPA as extractant, kerosene as a diluent, and optimization of the effective parameters were investigated. In addition to uranium and thorium, rare earths elements also exist in Saghand ore. The effect of p H on the extraction of Yb and other existing elements shows that their extractions increase by increasing p H. The extraction of Yb, U, La, Y, Ce and Fe in p H=2 were 99.9, 83, 13.5, 99.8, 8.5 and 27.4%, respectively. The increasing of the A/O ratio decreases the extraction of other elements more than Yb where it resulted in the increasing of the Yb separation. The theoretical number of extraction stages were determined in p H=2 and A/O=9 using McCabe-Thiele diagram. Stripping of the organic phase was also carried out by different concentrations of nitric acid.

  6. Therapeutic effects of marshmallow (Althaea officinalis L.) extract on plasma biochemical parameters of common carp infected with Aeromonas hydrophila.

    Science.gov (United States)

    Banaee, Mahdi; Soleimany, Vahid; Nematdoost Haghi, Behzad

    2017-01-01

    This study evaluated preclinical and clinical safety of marshmallow ( Althaea officinalis L.) extract as a naturopathic medicine in common carp deliberately infected with Aeromonas hydrophila . The fish were fed 0 (control), 2.50, 5.00 and 10.00 g of marshmallow extract for 60 days in a preclinical experiment and then, challenged with A. hydrophila for a 10-day experiment. Significant increases were observed in aspartate aminotransferase (AST), lactate dehydrogenase (LDH), alkaline phosphatase (ALP), creatine phosphokinase (CPK) activities and plasma creatinine levels in fish fed 10 g marshmallow extract per kg feed. However, alanine aminotransferase (ALT) significantly decreased on day 60. The fish fed 2.50 g marshmallow extract per kg feed indicated increased levels of total protein and globulin. There were no significant changes in albumin levels ( p > 0.05). 2.50 and 5.00 g marshmallow significantly decreased triglyceride and cholesterol levels and increased glucose levels ( p Marshmallow extract at 5.00 and 10.00 g can adjust plasma biochemical parameters in fish challenged with A. hydrophila . The results of preclinical studies and pharmaceutical toxicity of marshmallow extract revealed that dietary levels lower than 5.00 g were safe and effective. The results of this clinical study demonstrated that marshmallow extract (5.00 g kg -1 feed) can protect fish against A. hydrophila .

  7. A Study of Parameters Affecting the Solvent Extraction-Flocculation Process of Used Lubricating Oil

    Directory of Open Access Journals (Sweden)

    Hussein Qasim Hussein

    2017-06-01

    Full Text Available The aim of this study was to investigate the effect of operating variables on, the percentage of removed sludge (PSR obtained during re-refining of 15W-40 Al-Durra spent lubricant by solvent extraction-flocculation treatment method. Binary solvents were used such as, Heavy Naphtha (H.N.: MEK (N:MEK, H.N. : n-Butanol (N:n-But, and H.N. : Iso-Butanol (N:Iso:But. The studied variables were mixing speed (300-900, rpm, mixing time (15-60, min, and operating temperature (2540, oC. This study showed that the studied operating variables have effects where, increasing the mixing time up to 45 min for H.N.: MEK, H.N.: n-Butanol and 30 min for H.N.: Iso-Butanol increased the PSR, after that percentage was decreased; increasing the mixing speed for all the studied solvents up to 700 rpm increased the PSR, after that the percentage was decreased, while increasing the operating temperature decreased the PSR for all the solvents. This study has resulted in reasonably accurate multivariate process correlation that relates the removed sludge percentage to the process variables. The determination coefficients (

  8. Effect of extraction method on the yield of furanocoumarins from fruits of Archangelica officinalis Hoffm.

    Science.gov (United States)

    Waksmundzka-Hajnos, M; Petruczynik, A; Dragan, A; Wianowska, D; Dawidowicz, A L

    2004-01-01

    Optimal conditions for the extraction and analysis of furanocoumarins from fruits of Archangelica officinalis Hoffm. have been determined. The following extraction methods were used: exhaustive extraction in a Soxhlet apparatus, ultrasonication at 25 and 60 degrees C, microwave-assisted solvent extraction in open and closed systems, and accelerated solvent extraction (ASE). In most cases the yields of furanocoumarins were highest using the ASE method. The effects of extracting solvent, temperature and time of extraction using this method were investigated. The highest yield of furanocoumarins by ASE was obtained with methanol at 100-130 degrees C for 10 min. The extraction yields of furanocoumarins from plant material by ultrasonication at 60 degrees C and microwave-assisted solvent extraction in an open system were comparable to the extraction yields obtained in the time- and solvent-consuming exhaustive process involving the Soxhlet apparatus.

  9. System and method for extracting dominant orientations from a scene

    Science.gov (United States)

    Straub, Julian; Rosman, Guy; Freifeld, Oren; Leonard, John J.; Fisher, III; , John W.

    2017-05-30

    In one embodiment, a method of identifying the dominant orientations of a scene comprises representing a scene as a plurality of directional vectors. The scene may comprise a three-dimensional representation of a scene, and the plurality of directional vectors may comprise a plurality of surface normals. The method further comprises determining, based on the plurality of directional vectors, a plurality of orientations describing the scene. The determined plurality of orientations explains the directionality of the plurality of directional vectors. In certain embodiments, the plurality of orientations may have independent axes of rotation. The plurality of orientations may be determined by representing the plurality of directional vectors as lying on a mathematical representation of a sphere, and inferring the parameters of a statistical model to adapt the plurality of orientations to explain the positioning of the plurality of directional vectors lying on the mathematical representation of the sphere.

  10. Method for Estimating the Parameters of LFM Radar Signal

    Directory of Open Access Journals (Sweden)

    Tan Chuan-Zhang

    2017-01-01

    Full Text Available In order to obtain reliable estimate of parameters, it is very important to protect the integrality of linear frequency modulation (LFM signal. Therefore, in the practical LFM radar signal processing, the length of data frame is often greater than the pulse width (PW of signal. In this condition, estimating the parameters by fractional Fourier transform (FrFT will cause the signal to noise ratio (SNR decrease. Aiming at this problem, we multiply the data frame by a Gaussian window to improve the SNR. Besides, for a further improvement of parameters estimation precision, a novel algorithm is derived via Lagrange interpolation polynomial, and we enhance the algorithm by a logarithmic transformation. Simulation results demonstrate that the derived algorithm significantly reduces the estimation errors of chirp-rate and initial frequency.

  11. A comparative study: the impact of different lipid extraction methods on current microalgal lipid research

    Science.gov (United States)

    2014-01-01

    Microalgae cells have the potential to rapidly accumulate lipids, such as triacylglycerides that contain fatty acids important for high value fatty acids (e.g., EPA and DHA) and/or biodiesel production. However, lipid extraction methods for microalgae cells are not well established, and there is currently no standard extraction method for the determination of the fatty acid content of microalgae. This has caused a few problems in microlagal biofuel research due to the bias derived from different extraction methods. Therefore, this study used several extraction methods for fatty acid analysis on marine microalga Tetraselmis sp. M8, aiming to assess the potential impact of different extractions on current microalgal lipid research. These methods included classical Bligh & Dyer lipid extraction, two other chemical extractions using different solvents and sonication, direct saponification and supercritical CO2 extraction. Soxhlet-based extraction was used to weigh out the importance of solvent polarity in the algal oil extraction. Coupled with GC/MS, a Thermogravimetric Analyser was used to improve the quantification of microalgal lipid extractions. Among these extractions, significant differences were observed in both, extract yield and fatty acid composition. The supercritical extraction technique stood out most for effective extraction of microalgal lipids, especially for long chain unsaturated fatty acids. The results highlight the necessity for comparative analyses of microalgae fatty acids and careful choice and validation of analytical methodology in microalgal lipid research. PMID:24456581

  12. Relationship Between Wood Color Parameters Measured by the CIELab System and Extractive and Phenol Content in Acacia mangium and Vochysia guatemalensis from Fast-Growth Plantations

    Directory of Open Access Journals (Sweden)

    Carolina Tenorio

    2012-03-01

    Full Text Available The heterogeneity of color distribution between sapwood and heartwood limits the market for wood from fast-growth plantations of tropical species. Wood color is associated with wood extractives contents. This study presents the relationship between wood color parameters measured by the CIELab color system and total amount of extractives and phenolic-type extractives in ethanol-toluene and hot water extracts of wood from two fast-growth plantation species. The results demonstrated that the difference in sapwood and hardwood color in Vochysia guatemalensis and Acacia mangium is caused by lower concentrations of extractives in sapwood of both species. Additionally, variations in total extractive and phenolic content have different effects on the color parameters (L*, a* and b* of both species studied. In Vochysia guatemalensis wood, parameter L* decreases as total extractive and phenolic content increases; however, parameter a* increases as the content of extractives and phenols increases. In Acacia mangium, the amount of phenols showed no relationship with the color parameters. The ethanol-toluene total extractive content, however, shows a relationship with several color parameters. An increase in the content of total extractives in water and ethanol-toluene increases parameter a*, but decreases parameter L*.

  13. Nucleic acid extraction, oligonucleotide probes and PCR methods

    International Nuclear Information System (INIS)

    Zhongtang Yu; Forster, R.J.

    2005-01-01

    analysis, and hybridization-based methods, such as RNA-targeted hybridization, fluorescence in situ hybridization (FISH), and microarray, have been employed. The application of these molecular techniques has been changing our perspectives about ruminal and GI microbiota. Except for FISH, all these methods analyse DNA or RNA extracted from samples collected from rumen or GI tracts. Therefore, reliable and efficient DNA/RNA extraction is the pre-requisite of molecular ecological studies of ruminal microbiota

  14. Analytical one parameter method for PID motion controller settings

    NARCIS (Netherlands)

    van Dijk, Johannes; Aarts, Ronald G.K.M.

    2012-01-01

    In this paper analytical expressions for PID-controllers settings for electromechanical motion systems are presented. It will be shown that by an adequate frequency domain oriented parametrization, the parameters of a PID-controller are analytically dependent on one variable only, the cross-over

  15. A general method of estimating stellar astrophysical parameters from photometry

    NARCIS (Netherlands)

    Belikov, A. N.; Roeser, S.

    2008-01-01

    Context. Applying photometric catalogs to the study of the population of the Galaxy is obscured by the impossibility to map directly photometric colors into astrophysical parameters. Most of all-sky catalogs like ASCC or 2MASS are based upon broad-band photometric systems, and the use of broad

  16. Extraction of electron beam dose parameters from EBT2 film data scored in a mini phantom.

    Science.gov (United States)

    O'Reilly, Dedri; Smit, Cobus J L; du Plessis, Freek C P

    2013-09-01

    Quality assurance of medical linear accelerators includes dosimetric parameter measurement of therapeutic electron beams e.g. relative dose at a depth of 80% (R₈₀). This parameter must be within a tolerance of 0.2 cm of the declared value. Cumbersome water tank measurements can be regarded as a benchmark to measure electron depth dose curves. A mini-phantom was designed and built, in which a strip of GAFCHROMIC® EBT2 film could be encased tightly for electron beam depth dose measurement. Depth dose data were measured for an ELEKTA Sl25 MLC, ELEKTA Precise, and ELEKTA Synergy (Elekta Oncology Systems, Crawley, UK) machines. The electron beam energy range was between 4 and 22 MeV among the machines. A 10 × 10 cm² electron applicator with 95 cm source-surface-distance was used on all the machines. 24 h after irradiation, the EBT2 film strips were scanned on Canon CanoScan N670U scanner. Afterwards, the data were analysed with in-house developed software that entailed optical density to dose conversion, and optimal fitting of the PDD data to de-noise the raw data. From the PDD data R₈₀ values were solved for and compared with acceptance values. A series of tests were also carried out to validate the use of the scanner for film Dosimetry. These tests are presented in this study. It was found that this method of R₈₀ evaluation was reliable with good agreement with benchmark water tank measurements using a commercial parallel plate ionization chamber as the radiation detector. The EBT2 film data yielded R₈₀ values that were on average 0.06 cm different from benchmark water tank measured R₈₀ values.

  17. Optimization of Extraction Conditions and HPTLC - UV Method for Determination of Quinine in Different Extracts of Cinchona species Bark

    Directory of Open Access Journals (Sweden)

    Dharam C. Jain

    2008-10-01

    Full Text Available A simple, precise and accurate high-performance thin-layer chromatographic method has been established for quantitative determination of quinine. Conditions were also optimized for best possible extraction of quinine via varying concentrations of diethyl amine in different solvents (n-hexane, chloroform, ethyl acetate and methanol for maximum recovery of quinine. Methanol modified with 20 % DEA found to be best for highest possible recovery of target analyte quinine. Chromatographic separation of quinine was performed on silica gel 60 F 254 HPTLC plates with ethyl acetate : diethyl amine in the proportion 88 : 12 (v/v, as mobile phase. The determination was carried out using the densitometric absorbance mode at 236 nm. Quinine response was found to be linear over the range 4–24 μg spot −1. The HPTLC method was evaluated in terms of specificity, precision, reproducibility, LOD – LOQ and robustness. Beside these parameters, number of theoretical plates and flow constant were also included as a part of validation

  18. An automatic scaling method for obtaining the trace and parameters from oblique ionogram based on hybrid genetic algorithm

    Science.gov (United States)

    Song, Huan; Hu, Yaogai; Jiang, Chunhua; Zhou, Chen; Zhao, Zhengyu; Zou, Xianjian

    2016-12-01

    Scaling oblique ionogram plays an important role in obtaining ionospheric structure at the midpoint of oblique sounding path. The paper proposed an automatic scaling method to extract the trace and parameters of oblique ionogram based on hybrid genetic algorithm (HGA). The extracted 10 parameters come from F2 layer and Es layer, such as maximum observation frequency, critical frequency, and virtual height. The method adopts quasi-parabolic (QP) model to describe F2 layer's electron density profile that is used to synthesize trace. And it utilizes secant theorem, Martyn's equivalent path theorem, image processing technology, and echoes' characteristics to determine seven parameters' best fit values, and three parameter's initial values in QP model to set up their searching spaces which are the needed input data of HGA. Then HGA searches the three parameters' best fit values from their searching spaces based on the fitness between the synthesized trace and the real trace. In order to verify the performance of the method, 240 oblique ionograms are scaled and their results are compared with manual scaling results and the inversion results of the corresponding vertical ionograms. The comparison results show that the scaling results are accurate or at least adequate 60-90% of the time.

  19. Research methods of the parameters of residential buildings construction

    Directory of Open Access Journals (Sweden)

    Grigor’ev Vladimir Aleksandrovich

    Full Text Available The analysis of construction theory and practice shows that rational organizational and technological parameters of the construction of residential buildings should be based on the manifestation in time and space of the most important stages construction with their harmonization. Basing on the experience of normalizing the construction duration, it is advisable to express the complex of residential buildings’ construction processes by their basic stages - preparatory period, underground part, aboveground part, external engineering networks and land improvement. The main indicators of the development and implementation of optimization solutions are: the total duration of the construction, the duration of the preparation period, the duration of the construction of the underground part, the duration of the construction of the aboveground part, the duration of external engineering networks laying, the duration of land improvement. The indicators of the total duration of the construction of residential buildings, the construction the underground and aboveground parts are determined on the basis of the operation of one assembly crane on an object of up to four sections. In case of more sections two (three cranes are considered and the total construction duration is set depending on these conditions. The duration of the construction of multisectional buildings is determined basing on the simultaneous construction of the stages or their combination with a certain time shift. However, this approach requires a significant amount of optimization solutions due to its multivariance. Therefore, in order to reduce the volume of calculations in some cases, for example, when planning the development of districts and neighborhoods, statistical methods can be used for determining the duration of the construction basing on the compilation of optimization solutions. The total duration of the construction and the duration of the main stages are multiple

  20. Large-scale parameter extraction in electrocardiology models through Born approximation

    KAUST Repository

    He, Yuan; Keyes, David E.

    2012-01-01

    One of the main objectives in electrocardiology is to extract physical properties of cardiac tissues from measured information on electrical activity of the heart. Mathematically, this is an inverse problem for reconstructing coefficients

  1. Automatic Extraction of Urban Built-Up Area Based on Object-Oriented Method and Remote Sensing Data

    Science.gov (United States)

    Li, L.; Zhou, H.; Wen, Q.; Chen, T.; Guan, F.; Ren, B.; Yu, H.; Wang, Z.

    2018-04-01

    Built-up area marks the use of city construction land in the different periods of the development, the accurate extraction is the key to the studies of the changes of urban expansion. This paper studies the technology of automatic extraction of urban built-up area based on object-oriented method and remote sensing data, and realizes the automatic extraction of the main built-up area of the city, which saves the manpower cost greatly. First, the extraction of construction land based on object-oriented method, the main technical steps include: (1) Multi-resolution segmentation; (2) Feature Construction and Selection; (3) Information Extraction of Construction Land Based on Rule Set, The characteristic parameters used in the rule set mainly include the mean of the red band (Mean R), Normalized Difference Vegetation Index (NDVI), Ratio of residential index (RRI), Blue band mean (Mean B), Through the combination of the above characteristic parameters, the construction site information can be extracted. Based on the degree of adaptability, distance and area of the object domain, the urban built-up area can be quickly and accurately defined from the construction land information without depending on other data and expert knowledge to achieve the automatic extraction of the urban built-up area. In this paper, Beijing city as an experimental area for the technical methods of the experiment, the results show that: the city built-up area to achieve automatic extraction, boundary accuracy of 2359.65 m to meet the requirements. The automatic extraction of urban built-up area has strong practicality and can be applied to the monitoring of the change of the main built-up area of city.

  2. Effect of various experimental parameters on the swelling and supercritical extraction properties of lignite

    Energy Technology Data Exchange (ETDEWEB)

    Hacimehmetoglu, S.; Sinag, A.; Tekes, A.T.; Misirlioglu, Z.; Canel, M. [Ankara University, Ankara (Turkey). Faculty of Science

    2007-07-01

    The original lignite sample, the samples swollen in dimethylsulfoxide (DMSO), dimethylformamide (DMF), pyridine, tetrahydrofuran (THF), acetone, ethylenediamine (EDA), N-methyl-2-pyrrolidone (NMP), tetrabutylammonium hydroxide (TBAH), the samples impregnated by ZnCl{sub 2} as catalyst and the samples both swollen in the solvents and impregnated by ZnCl{sub 2} were subjected to the supercritical toluene extraction and the effects of temperature, pressure, pre-swelling procedure, hydrogen donor solvent (tetralin), and catalyst on the extract yields were investigated.

  3. OPTIMIZATION OF HIBISCUS SABDARIFFA L. (ROSELLE) ANTHOCYANIN AQUEOUS-ETHANOL EXTRACTION PARAMETERS USING RESPONSE SURFACE METHODOLOGY

    OpenAIRE

    ANILÚ MIRANDA-MEDINA; PATRICIA M. HAYWARD-JONES; OCTAVIO CARVAJAL-ZARRABAL; LUZ DEL ALBA LADRÓN DE GUEVARA-VELA; YERIKC DAVID RAMÍREZ-VILLAGÓMEZ; DULCE M. BARRADAS-DERMITZ; GEORGINA LUNA-CARRILLO; MARÍA G. AGUILAR-USCANGA

    2018-01-01

    Anthocyanins along with protocatechuic acid and quercetin have been recognized as bioactive compounds in Hibiscus sabdariffa L. aqueous extracts. Characteristic anthocyanin absorption in the visible region makes their quantification possible without the interference of the other two compounds, and also can favor its potential application as an alternative to organic-based dye sensitized solar cell, in various forms. In order to optimize measurable factors linked to the extraction of these fla...

  4. Effects of methods of attenuation correction on source parameter determination

    Science.gov (United States)

    Sonley, Eleanor; Abercrombie, Rachel E.

    We quantify the effects of using different approaches to model individual earthquake spectra. Applying different approaches can introduce significant variability in the calculated source parameters, even when applied to the same data. To compare large and small earthquake source parameters, the results of multiple studies need to be combined to extend the magnitude range, but the variability introduced by the different approaches hampers the outcome. When studies are combined, there is large uncertainty and large scatter and some systematic differences have been neglected. We model individual earthquake spectra from repeating earthquakes (M˜2) at Parkfield, CA, recorded by a borehole network. We focus on the effects of trade-offs between attenuation (Q) and corner frequency in spectral fitting and the effect of the model shape at the corner frequency on radiated energy. The trade-off between attenuation and corner frequency can increase radiated energy by up to 400% and seismic moment by up to 100%.

  5. Biosensor method and system based on feature vector extraction

    Science.gov (United States)

    Greenbaum, Elias [Knoxville, TN; Rodriguez, Jr., Miguel; Qi, Hairong [Knoxville, TN; Wang, Xiaoling [San Jose, CA

    2012-04-17

    A method of biosensor-based detection of toxins comprises the steps of providing at least one time-dependent control signal generated by a biosensor in a gas or liquid medium, and obtaining a time-dependent biosensor signal from the biosensor in the gas or liquid medium to be monitored or analyzed for the presence of one or more toxins selected from chemical, biological or radiological agents. The time-dependent biosensor signal is processed to obtain a plurality of feature vectors using at least one of amplitude statistics and a time-frequency analysis. At least one parameter relating to toxicity of the gas or liquid medium is then determined from the feature vectors based on reference to the control signal.

  6. Measurement of Tritium Activity in Plants by Ice Extraction Method

    International Nuclear Information System (INIS)

    Pelled, O.; Ovad, S.; Tubul, Y.; Tsroya, S.; Gonen, R.; Abraham, A.; Weinstein, M.; German, U.

    2014-01-01

    Tritium is produced primarily by interactions of cosmic rays with the atmosphere. However, nuclear installations may add significantly tritium to the surroundings, increasing its concentration. The main sources of tritium released by man are linked to the nuclear power cycle: nuclear power stations, nuclear fuel reprocessing plants or tritium production plants. Tritium is found in the environment mainly as tritiated water, in gaseous or liquid form (HTO, T2O), in the surrounding air and in soil. It accumulates in plants, which may use as a measure to the level of tritium concentration in the environment. The most common routes of tritium uptake from the environment in plants are from atmospheric humidity and by precipitation water which entered the soil. The fraction of tritium bound to the plant tissue is small compared to that present as tritiated water in the plant (from 0.06% to 0.3% for growing crops). The tritiated water uptake is through the roots, as tritiated water from the soil follows a pathway similar to that of ordinary water. As most tritium in plants consists of tritiated water, the measurements of only the tissue free water tritium concentration (as HTO or T2O) gives an accurate estimate of the tritium content in the plant. Analyzing free tritium in biological matrices usually requires using the freeze-drying method to extract the water from the sample, and then measure the water collected in a cold trap with a Liquid Scintillation Counter (LSC). The 'freeze-drying' occurs because of the sublimation of the frozen water inside the plant, that takes place when the temperature is beneath the triple point and the vapour pressure is low. In the temperature range of -5° to -10° C the mechanism that plants use to avoid freezing is drawing of water from the cell protoplasm into the intercellular spaces. Changes in cell membrane permeability allow water to leave the cell and enter the spaces between the cells where it freezes instead of freezing within the

  7. Determination of the antioxidant capacity of two seagrass species according to the extraction method

    Directory of Open Access Journals (Sweden)

    Kethia L. González

    2016-10-01

    Full Text Available Context: There is a wide variety of methods for obtaining of plant extracts that enable a good yield of bioactive metabolites. For several years, extractive techniques have been perfected for obtaining natural extracts with powerful pharmacological properties. Aims: To determine the influence of various extraction methods (infusion, decoction, microwave, maceration with heat and agitation, and constant heat and agitation on the content of solids, phenolic compounds and antioxidant capacity of marine angiosperms Thalassia testudinum Banks ex König (Hyrocharitacea and Syringodium filiforme kützing (Cymodoceaceae. Methods: The soluble solids content was determined by the gravimetric method; total phenolic content, using Folin-Ciocalteu method, and the antioxidant capacity by 2,2-diphenyl-1 picrylhydrazyl (DPPH method. Results: Results showed the effectiveness of extraction by decoction for T. testudinum and by microwave for S. filiforme, among the methods that use water as the extraction solvent. In the case those that use the hydroalcoholic mixture as solvent extraction, maceration with agitation and heat extraction showed the higher yields of soluble solids and total polyphenols, as well as a higher antioxidant activity for both species. Conclusions: Results showed the effectiveness of extraction by decoction for T. testudinum and by microwave for S. filiforme, among the methods that use water as extraction solvent. In the case those that use hydroalcoholic mixture as solvent extraction, maceration with agitation and heat extraction showed the higher yields of soluble solids and total polyphenols, as well as a higher antioxidant activity for both species.

  8. Effect of DNA extraction and sample preservation method on rumen bacterial population.

    Science.gov (United States)

    Fliegerova, Katerina; Tapio, Ilma; Bonin, Aurelie; Mrazek, Jakub; Callegari, Maria Luisa; Bani, Paolo; Bayat, Alireza; Vilkki, Johanna; Kopečný, Jan; Shingfield, Kevin J; Boyer, Frederic; Coissac, Eric; Taberlet, Pierre; Wallace, R John

    2014-10-01

    The comparison of the bacterial profile of intracellular (iDNA) and extracellular DNA (eDNA) isolated from cow rumen content stored under different conditions was conducted. The influence of rumen fluid treatment (cheesecloth squeezed, centrifuged, filtered), storage temperature (RT, -80 °C) and cryoprotectants (PBS-glycerol, ethanol) on quality and quantity parameters of extracted DNA was evaluated by bacterial DGGE analysis, real-time PCR quantification and metabarcoding approach using high-throughput sequencing. Samples clustered according to the type of extracted DNA due to considerable differences between iDNA and eDNA bacterial profiles, while storage temperature and cryoprotectants additives had little effect on sample clustering. The numbers of Firmicutes and Bacteroidetes were lower (P rumen fluid subjected to the eDNA isolation procedure considerably changed the ratio of molecular operational taxonomic units (MOTUs) of Bacteroidetes and Firmicutes. Intracellular DNA extraction using bead-beating method from cheesecloth sieved rumen content mixed with PBS-glycerol and stored at -80 °C was found as the optimal method to study ruminal bacterial profile. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Simultaneous spectrophotometric determination of uranium and zirconium using cloud point extraction and multivariate methods

    International Nuclear Information System (INIS)

    Ghasemi, Jahan B.; Hashemi, Beshare; Shamsipur, Mojtaba

    2012-01-01

    A cloud point extraction (CPE) process using the nonionic surfactant Triton X-114 to simultaneous extraction and spectrophotometric determination of uranium and zirconium from aqueous solution using partial least squares (PLS) regression is investigated. The method is based on the complexation reaction of these cations with Alizarin Red S (ARS) and subsequent micelle-mediated extraction of products. The chemical parameters affecting the separation phase and detection process were studied and optimized. Under the optimum experimental conditions (i.e. pH 5.2, Triton X-114 = 0.20%, equilibrium time 10 min and cloud point 45 C), calibration graphs were linear in the range of 0.01-3 mg L -1 with detection limits of 2.0 and 0.80 μg L -1 for U and Zr, respectively. The experimental calibration set was composed of 16 sample solutions using an orthogonal design for two component mixtures. The root mean square error of predictions (RMSEPs) for U and Zr were 0.0907 and 0.1117, respectively. The interference effect of some anions and cations was also tested. The method was applied to the simultaneous determination of U and Zr in water samples.

  10. Method for extracting copper, silver and related metals

    Science.gov (United States)

    Moyer, Bruce A.; McDowell, W. J.

    1990-01-01

    A process for selectively extracting precious metals such as silver and gold concurrent with copper extraction from aqueous solutions containing the same. The process utilizes tetrathiamacrocycles and high molecular weight organic acids that exhibit a synergistic relationship when complexing with certain metal ions thereby removing them from ore leach solutions.

  11. Efficient point cloud data processing in shipbuilding: Reformative component extraction method and registration method

    Directory of Open Access Journals (Sweden)

    Jingyu Sun

    2014-07-01

    Full Text Available To survive in the current shipbuilding industry, it is of vital importance for shipyards to have the ship components’ accuracy evaluated efficiently during most of the manufacturing steps. Evaluating components’ accuracy by comparing each component’s point cloud data scanned by laser scanners and the ship’s design data formatted in CAD cannot be processed efficiently when (1 extract components from point cloud data include irregular obstacles endogenously, or when (2 registration of the two data sets have no clear direction setting. This paper presents reformative point cloud data processing methods to solve these problems. K-d tree construction of the point cloud data fastens a neighbor searching of each point. Region growing method performed on the neighbor points of the seed point extracts the continuous part of the component, while curved surface fitting and B-spline curved line fitting at the edge of the continuous part recognize the neighbor domains of the same component divided by obstacles’ shadows. The ICP (Iterative Closest Point algorithm conducts a registration of the two sets of data after the proper registration’s direction is decided by principal component analysis. By experiments conducted at the shipyard, 200 curved shell plates are extracted from the scanned point cloud data, and registrations are conducted between them and the designed CAD data using the proposed methods for an accuracy evaluation. Results show that the methods proposed in this paper support the accuracy evaluation targeted point cloud data processing efficiently in practice.

  12. Resist Parameter Extraction from Line-and-Space Patterns of Chemically Amplified Resist for Extreme Ultraviolet Lithography

    Science.gov (United States)

    Kozawa, Takahiro; Oizumi, Hiroaki; Itani, Toshiro; Tagawa, Seiichi

    2010-11-01

    The development of extreme ultraviolet (EUV) lithography has progressed owing to worldwide effort. As the development status of EUV lithography approaches the requirements for the high-volume production of semiconductor devices with a minimum line width of 22 nm, the extraction of resist parameters becomes increasingly important from the viewpoints of the accurate evaluation of resist materials for resist screening and the accurate process simulation for process and mask designs. In this study, we demonstrated that resist parameters (namely, quencher concentration, acid diffusion constant, proportionality constant of line edge roughness, and dissolution point) can be extracted from the scanning electron microscopy (SEM) images of patterned resists without the knowledge on the details of resist contents using two types of latest EUV resist.

  13. Effects of extraction methods of phenolic compounds from Xanthium strumarium L. and their antioxidant activity

    Directory of Open Access Journals (Sweden)

    R. Scherer

    2014-03-01

    Full Text Available The effect of extraction methods and solvents on overall yield, total phenolic content, antioxidant activity, and the composition of the phenolic compounds in Xanthium strumarium extracts were studied. The antioxidant activity was determined by using 2,2-diphenyl-1-picrylhydrazyl radical (DPPH, and the composition of the phenolic compounds was determined by HPLC-DAD and LC/MS. All results were affected by the extraction method, especially by the solvent used, and the best results were obtained with the methanol extract. The methanolic and ethanolic extracts exhibited strong antioxidant activity, and the chlorogenic and ferulic acids were the most abundant phenolic compounds in the extracts.

  14. Evaluation of sample extraction methods for proteomics analysis of green algae Chlorella vulgaris.

    Science.gov (United States)

    Gao, Yan; Lim, Teck Kwang; Lin, Qingsong; Li, Sam Fong Yau

    2016-05-01

    Many protein extraction methods have been developed for plant proteome analysis but information is limited on the optimal protein extraction method from algae species. This study evaluated four protein extraction methods, i.e. direct lysis buffer method, TCA-acetone method, phenol method, and phenol/TCA-acetone method, using green algae Chlorella vulgaris for proteome analysis. The data presented showed that phenol/TCA-acetone method was superior to the other three tested methods with regards to shotgun proteomics. Proteins identified using shotgun proteomics were validated using sequential window acquisition of all theoretical fragment-ion spectra (SWATH) technique. Additionally, SWATH provides protein quantitation information from different methods and protein abundance using different protein extraction methods was evaluated. These results highlight the importance of green algae protein extraction method for subsequent MS analysis and identification. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Effect of Syzygium cumini and Bauhinia forficata aqueous-leaf extracts on oxidative and mitochondrial parameters in vitro

    Science.gov (United States)

    Ecker, Assis; Araujo Vieira, Francielli; de Souza Prestes, Alessandro; Mulling dos Santos, Matheus; Ramos, Angelica; Dias Ferreira, Rafael; Teixeira de Macedo, Gabriel; Vargas Klimaczewski, Claudia; Lopes Seeger, Rodrigo; Teixeira da Rocha, João Batista; de Vargas Barbosa, Nilda B.

    2015-01-01

    Aqueous-leaf extract of Syzygium cumini and Bauhinia forficata are traditionally used in the treatment of diabetes and cancer, especially in South America, Africa, and Asia. In this study, we analyzed the effects of these extracts on oxidative and mitochondrial parameters in vitro, as well as their protective activities against toxic agents. Phytochemical screenings of the extracts were carried out by HPLC analysis. The in vitro antioxidant capacities were compared by DPPH radical scavenging and Fe2+ chelating activities. Mitochondrial parameters observed were swelling, lipid peroxidation and dehydrogenase activity. The major chemical constituent of S. cumini was rutin. In B. forficata were predominant quercetin and gallic acid. S. cumini reduced DPPH radical more than B. forficata, and showed iron chelating activity at all tested concentrations, while B. forficata had not similar property. In mitochondria, high concentrations of B. forficata alone induced a decrease in mitochondrial dehydrogenase activity, but low concentrations of this extract prevented the effect induced by Fe2++H2O2. This was also observed with high concentrations of S. cumini. Both extracts partially prevented the lipid peroxidation induced by Fe2+/citrate. S. cumini was effective against mitochondrial swelling induced by Ca2+, while B. forficata alone induced swelling more than Ca2+. This study suggests that leaf extract of S. cumini might represent a useful therapeutic for the treatment of diseases related with mitochondrial dysfunctions. On the other hand, the consumption of B. forficata should be avoided because mitochondrial damages were observed, and this possibly may pose risk to human health. PMID:27152111

  16. Optimization of Robotic Spray Painting process Parameters using Taguchi Method

    Science.gov (United States)

    Chidhambara, K. V.; Latha Shankar, B.; Vijaykumar

    2018-02-01

    Automated spray painting process is gaining interest in industry and research recently due to extensive application of spray painting in automobile industries. Automating spray painting process has advantages of improved quality, productivity, reduced labor, clean environment and particularly cost effectiveness. This study investigates the performance characteristics of an industrial robot Fanuc 250ib for an automated painting process using statistical tool Taguchi’s Design of Experiment technique. The experiment is designed using Taguchi’s L25 orthogonal array by considering three factors and five levels for each factor. The objective of this work is to explore the major control parameters and to optimize the same for the improved quality of the paint coating measured in terms of Dry Film thickness(DFT), which also results in reduced rejection. Further Analysis of Variance (ANOVA) is performed to know the influence of individual factors on DFT. It is observed that shaping air and paint flow are the most influencing parameters. Multiple regression model is formulated for estimating predicted values of DFT. Confirmation test is then conducted and comparison results show that error is within acceptable level.

  17. Influence of flowfield and vehicle parameters on engineering aerothermal methods

    Science.gov (United States)

    Wurster, Kathryn E.; Zoby, E. Vincent; Thompson, Richard A.

    1989-01-01

    The reliability and flexibility of three engineering codes used in the aerosphace industry (AEROHEAT, INCHES, and MINIVER) were investigated by comparing the results of these codes with Reentry F flight data and ground-test heat-transfer data for a range of cone angles, and with the predictions obtained using the detailed VSL3D code; the engineering solutions were also compared. In particular, the impact of several vehicle and flow-field parameters on the heat transfer and the capability of the engineering codes to predict these results were determined. It was found that entropy, pressure gradient, nose bluntness, gas chemistry, and angle of attack all affect heating levels. A comparison of the results of the three engineering codes with Reentry F flight data and with the predictions obtained of the VSL3D code showed a very good agreement in the regions of the applicability of the codes. It is emphasized that the parameters used in this study can significantly influence the actual heating levels and the prediction capability of a code.

  18. Toxicological evaluations of Stigma maydis (corn silk aqueous extract on hematological and lipid parameters in Wistar rats

    Directory of Open Access Journals (Sweden)

    Sabiu Saheed

    2015-01-01

    Full Text Available Despite the acclaimed phytotherapeutic attributes of Stigma maydis in folkloric medicine, there is paucity of information on its toxicity profile on hematological and lipid parameters. The toxicological effect of aqueous extract of corn silk at 100, 200 and 400 mg/kg body weight on hematological indices in Wistar rats were evaluated progressively at 24 h after 1, 7, 14, 21 and 28 days. Lipid parameters were also analyzed at the end of the experimental period. We observed that the extract did not exhibit any significant (p > 0.05 effect on red blood cells, hematocrit, hemoglobin, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, and mean platelet volume at all the tested doses. The study however showed a significant increase in the serum levels of white blood cell, platelet, lymphocytes, high-density lipoprotein cholesterol; as well as feeding pattern in the animals, while the concentrations of total cholesterol, low-density lipoprotein cholesterol, and artherogenic index value were significantly lowered. These findings are suggestive of non-hematotoxic potential of the extract. Overall, the effect exhibited by corn silk extract in this study proved that, it is unlikely to be hematotoxic and could be a good candidature in the management of coronary heart diseases if consumed at the doses investigated.

  19. Toxicological evaluations of Stigma maydis (corn silk) aqueous extract on hematological and lipid parameters in Wistar rats.

    Science.gov (United States)

    Saheed, Sabiu; Oladipipo, Ajani E; Abdulazeez, Abubakar A; Olarewaju, Sulyman A; Ismaila, Nurain O; Emmanuel, Irondi A; Fatimah, Quadri D; Aisha, Abubakar Y

    2015-01-01

    Despite the acclaimed phytotherapeutic attributes of Stigma maydis in folkloric medicine, there is paucity of information on its toxicity profile on hematological and lipid parameters. The toxicological effect of aqueous extract of corn silk at 100, 200 and 400 mg/kg body weight on hematological indices in Wistar rats were evaluated progressively at 24 h after 1, 7, 14, 21 and 28 days. Lipid parameters were also analyzed at the end of the experimental period. We observed that the extract did not exhibit any significant ( p  > 0.05) effect on red blood cells, hematocrit, hemoglobin, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, and mean platelet volume at all the tested doses. The study however showed a significant increase in the serum levels of white blood cell, platelet, lymphocytes, high-density lipoprotein cholesterol; as well as feeding pattern in the animals, while the concentrations of total cholesterol, low-density lipoprotein cholesterol, and artherogenic index value were significantly lowered. These findings are suggestive of non-hematotoxic potential of the extract. Overall, the effect exhibited by corn silk extract in this study proved that, it is unlikely to be hematotoxic and could be a good candidature in the management of coronary heart diseases if consumed at the doses investigated.

  20. Comparison of parameter-adapted segmentation methods for fluorescence micrographs.

    Science.gov (United States)

    Held, Christian; Palmisano, Ralf; Häberle, Lothar; Hensel, Michael; Wittenberg, Thomas

    2011-11-01

    Interpreting images from fluorescence microscopy is often a time-consuming task with poor reproducibility. Various image processing routines that can help investigators evaluate the images are therefore useful. The critical aspect for a reliable automatic image analysis system is a robust segmentation algorithm that can perform accurate segmentation for different cell types. In this study, several image segmentation methods were therefore compared and evaluated in order to identify the most appropriate segmentation schemes that are usable with little new parameterization and robustly with different types of fluorescence-stained cells for various biological and biomedical tasks. The study investigated, compared, and enhanced four different methods for segmentation of cultured epithelial cells. The maximum-intensity linking (MIL) method, an improved MIL, a watershed method, and an improved watershed method based on morphological reconstruction were used. Three manually annotated datasets consisting of 261, 817, and 1,333 HeLa or L929 cells were used to compare the different algorithms. The comparisons and evaluations showed that the segmentation performance of methods based on the watershed transform was significantly superior to the performance of the MIL method. The results also indicate that using morphological opening by reconstruction can improve the segmentation of cells stained with a marker that exhibits the dotted surface of cells. Copyright © 2011 International Society for Advancement of Cytometry.

  1. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin

    OpenAIRE

    Thoisen, Christina; Hansen, Benni Winding; Nielsen, S?ren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equip...

  2. Walnut and almond oil screw-press extraction at industrial scale: Effects of process parameters on oil yield and quality

    Directory of Open Access Journals (Sweden)

    M. L. Martínez

    2018-01-01

    Full Text Available Walnut and almond kernels are highly nutritious mainly due to their high oil contents. In this study, 32 factorial experimental designs were used to optimize processes for oil extraction by screw-pressing at industrial scale. Experimental designs included seed moisture content (SMC, and restriction die (RD as the main processing parameters. Theoretical models were scanned against experimental data in order to optimize oil extraction conditions. The response variables analyzed were oil yield (OY, fine solid content (FC in oil, and oil quality parameters. Fitted models for OY indicated maximum predicted values similar to the highest experimental values. Walnut oil extractions showed a maximum OY (84.5 ± 2.3 % at 7.21% SMC, and 10 mm RD. For almond kernels, maximum OY (71.9 ± 3.5% was obtained at 9.42% SMC, and 12 mm RD. Chemical quality parameters from both oils were in the ranges stated in Codex (FAO/WHO standards for virgin (non-refined oils.

  3. Walnut and almond oil screw-press extraction at industrial scale: Effects of process parameters on oil yield and quality

    International Nuclear Information System (INIS)

    Martínez, M. L.; Bordón, M.G.; Bodoira, R. M.; Penci, M.C.; Ribotta, P.D.; Maestri, D.M.

    2017-01-01

    Walnut and almond kernels are highly nutritious mainly due to their high oil contents. In this study, 32 factorial experimental designs were used to optimize processes for oil extraction by screw-pressing at industrial scale. Experimental designs included seed moisture content (SMC), and restriction die (RD) as the main processing parameters. Theoretical models were scanned against experimental data in order to optimize oil extraction conditions. The response variables analyzed were oil yield (OY), fine solid content (FC) in oil, and oil quality parameters. Fitted models for OY indicated maximum predicted values similar to the highest experimental values. Walnut oil extractions showed a maximum OY (84.5 ± 2.3 %) at 7.21% SMC, and 10 mm RD. For almond kernels, maximum OY (71.9 ± 3.5%) was obtained at 9.42% SMC, and 12 mm RD. Chemical quality parameters from both oils were in the ranges stated in Codex (FAO/WHO) standards for virgin (non-refined) oils. [es

  4. Pressurised liquid extraction of flavonoids in onions. Method development and validation

    DEFF Research Database (Denmark)

    Søltoft, Malene; Christensen, J.H.; Nielsen, J.

    2009-01-01

    A rapid and reliable analytical method for quantification of flavonoids in onions was developed and validated. Five extraction methods were tested on freeze-dried onions and subsequently high performance liquid chromatography (HPLC) with UV detection was used for quantification of seven flavonoids...... extraction methods. However. PLE was the preferred extraction method because the method can be highly automated, use only small amounts of solvents, provide the cleanest extracts, and allow the extraction of light and oxygen-sensitive flavonoids to be carried out in an inert atmosphere protected from light......-step PLE method showed good selectivity, precision (RSDs = 3.1-11%) and recovery of the extractable flavonoids (98-99%). The method also appeared to be a multi-method, i.e. generally applicable to, e.g. phenolic acids in potatoes and carrots....

  5. Multi-parameter Analysis and Inversion for Anisotropic Media Using the Scattering Integral Method

    KAUST Repository

    Djebbi, Ramzi

    2017-10-24

    The main goal in seismic exploration is to identify locations of hydrocarbons reservoirs and give insights on where to drill new wells. Therefore, estimating an Earth model that represents the right physics of the Earth\\'s subsurface is crucial in identifying these targets. Recent seismic data, with long offsets and wide azimuth features, are more sensitive to anisotropy. Accordingly, multiple anisotropic parameters need to be extracted from the recorded data on the surface to properly describe the model. I study the prospect of applying a scattering integral approach for multi-parameter inversion for a transversely isotropic model with a vertical axis of symmetry. I mainly analyze the sensitivity kernels to understand the sensitivity of seismic data to anisotropy parameters. Then, I use a frequency domain scattering integral approach to invert for the optimal parameterization. The scattering integral approach is based on the explicit computation of the sensitivity kernels. I present a new method to compute the traveltime sensitivity kernels for wave equation tomography using the unwrapped phase. I show that the new kernels are a better alternative to conventional cross-correlation/Rytov kernels. I also derive and analyze the sensitivity kernels for a transversely isotropic model with a vertical axis of symmetry. The kernels structure, for various opening/scattering angles, highlights the trade-off regions between the parameters. For a surface recorded data, I show that the normal move-out velocity vn, ƞ and δ parameterization is suitable for a simultaneous inversion of diving waves and reflections. Moreover, when seismic data is inverted hierarchically, the horizontal velocity vh, ƞ and ϵ is the parameterization with the least trade-off. In the frequency domain, the hierarchical inversion approach is naturally implemented using frequency continuation, which makes vh, ƞ and ϵ parameterization attractive. I formulate the multi-parameter inversion using the

  6. Methods and apparatus for multi-parameter acoustic signature inspection

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, Aaron A [Richland, WA; Samuel, Todd J [Pasco, WA; Valencia, Juan D [Kennewick, WA; Gervais, Kevin L [Richland, WA; Tucker, Brian J [Pasco, WA; Kirihara, Leslie J [Richland, WA; Skorpik, James R [Kennewick, WA; Reid, Larry D [Benton City, WA; Munley, John T [Benton City, WA; Pappas, Richard A [Richland, WA; Wright, Bob W [West Richland, WA; Panetta, Paul D [Richland, WA; Thompson, Jason S [Richland, WA

    2007-07-24

    A multiparameter acoustic signature inspection device and method are described for non-invasive inspection of containers. Dual acoustic signatures discriminate between various fluids and materials for identification of the same.

  7. Radiator Enhanced Geothermal System - A Revolutionary Method for Extracting Geothermal Energy

    Science.gov (United States)

    Karimi, S.; Marsh, B. D.; Hilpert, M.

    2017-12-01

    A new method of extracting geothermal energy, the Radiator Enhanced Geothermal System (RAD-EGS) has been developed. RAD-EGS attempts to mimic natural hydrothermal systems by 1) generating a vertical vane of artificially produced high porosity/permeability material deep in a hot sedimentary aquifer, 2) injecting water at surface temperatures to the bottom of the vane, where the rock is the hottest, 3) extracting super-heated water at the top of the vane. The novel RAD-EGS differs greatly from the currently available Enhanced Geothermal Systems in vane orientation, determined in the governing local crustal stress field by Shmax and Sl (meaning it is vertical), and in the vane location in a hot sedimentary aquifer, which naturally increases the longevity of the system. In this study, we explore several parameters regimes affecting the water temperature in the extraction well, keeping in mind that the minimum temperature of the extracted water has to be 150 °C in order for a geothermal system to be commercially viable. We used the COMSOL finite element package to simulate coupled heat and fluid transfer within the RAD-EGS model. The following geologic layers from top to bottom are accounted for in the model: i) confining upper layer, ii) hot sedimentary aquifer, and iii) underlying basement rock. The vane is placed vertically within the sedimentary aquifer. An injection well and an extraction well are also included in the simulation. We tested the model for a wide range of various parameters including background heat flux, thickness of geologic layers, geometric properties of the vane, diameter and location of the wells, fluid flow within the wells, regional hydraulic gradient, and permeability and porosity of the layers. The results show that among the aforementioned parameters, background heat flux and the depth of vane emplacement are highly significant in determining the level of commercial viability of the geothermal system. These results indicate that for the

  8. Phytochemically evaluation and net anti-oxidant activity of Tunisian Melia azedarach leaves extract from their ProAntidex parameter

    Directory of Open Access Journals (Sweden)

    Maroua Akacha

    2016-06-01

    Full Text Available Phytotherapy is a discipline which is interested in the design, the preparation and the interpretation of structure activity relationship of the natural bioactive molecules. In this context, ethanolic leaves extract of Melia azedarach L. was phytochemically analysed on the bases of HPLC and by GC–MS. Extract wase tested for his in vitro antioxidant activities by 1,1-diphenyl-2-picrylhydrazyl (DPPH, H2O2, hydroxyl radical scavenging activity, Ferric Reducing Power (FRP and Ferrous ion chelating abilities methods. The antioxidant activity of the extract was analyzed simultaneously with their pro-oxidant capacity. The ratio of pro-oxidant to the antioxidant activity (ProAntidex represents a useful index of the net free radical scavenging potential of the synthesized compounds. Tested extract showed significant antioxidant activity with a moderate ProAntidex.

  9. Antioxidative and Antimelanoma Effects of Various Tea Extracts via a Green Extraction Method

    Directory of Open Access Journals (Sweden)

    Yihui Chen

    2018-01-01

    Full Text Available Tea (Camellia sinensis contains high level of antioxidant elements and is a well-known beverage consumed worldwide. The purpose of this study is to compare different concentrations of green tea, black tea, oolong tea 861, oolong tea 732, and jasmine green tea. These five types of tea extracts were known to have antioxidative properties, reducing power, and metal ion chelating activity. The current study compared these five extracts in terms of their inhibiting effects on human malignant melanoma: A2058 and A375. To determine the cell viability between normal cell and malignant melanoma cells, an MTT assay was applied to evaluate the cytotoxic potential on human melanoma cells, with all tea extracts showing decreased cell viability with increasing tea extract concentrations. Cytotoxicity on HaCat (normal skin cells showed no effect on the cell viabilities at lower concentrations of the tea extracts. These results suggest the antioxidative effect of five tea extracts that protect against oxidation and melanoma production, with green tea and jasmine green tea showing the lowest cell viability when tested against malignant melanoma cells.

  10. Effect of plant extracts and a disinfectant on biological parameters and pathogenicity of the fungus Beauveria bassiana (Bals. Vuill. (Ascomycota: Cordycipitaceae

    Directory of Open Access Journals (Sweden)

    C. C. Martins

    Full Text Available Abstract The fungus Beauveria bassiana is naturally found in poultry houses and causes high rates of mortality in Alphitobius diaperinus. Laboratory and field experiments have shown the potential of this fungus as an insect control agent. However, in poultry houses, bacteria as Salmonella, can be found and have been studied alternative control methods for this pathogen. Thus, this study aimed to evaluate the effect of plant extracts and a disinfectant on the fungus Beauveria bassiana (strain Unioeste 4. Conidial viability, colony-forming unit (CFU counts, vegetative growth, conidia production, insecticidal activity of the fungus and compatibility were used as parameters in the evaluation of the effect of these products on the fungus. Alcoholic and aqueous extracts of jabuticaba (Myrciaria cauliflora (Mart., guava (Psidium guajava (L., and jambolan (Syzygium cumini (L., at concentrations of 10% as well as the commercial disinfectant, Peroxitane® 1512 AL, were evaluated at the recommended concentrations (RC, 1:200 (RC, 0.5 RC and 2 RC. There was a negative influence of alcoholic and aqueous extracts of jabuticaba, guava and three dilutions of Peroxitane on the viability of conidia. The CFUs and vegetative growth of the fungus were affected only by the Peroxitane (all dilutions. For conidial production, the aqueous extract of guava had a positive effect, increasing production, while the Peroxitane at the R and RC concentrations resulted in a negative influence. The mortality of A. diaperinus, caused by the fungus after exposure to these products, was 60% for the peracetic acid at 0.5 RC, and above 80% for the extracts. Thus, the results showed that all the extracts and Peroxitane at RC 0.5 are compatible with the fungus B. bassiana Unioeste 4, however only the extracts had a low impact on inoculum potential.

  11. The Effect of Crude Extract of Turbo coronatus from the Persian Gulf on Serum Biochemical Parameters and Hematiological Parameters of Rats

    Directory of Open Access Journals (Sweden)

    Amir Vazirizadeh

    2017-05-01

    Full Text Available : Turbotoxins are marine secondary metabolites that produce in Turbinidae family and were isolated from Japanese Turbo marmorata for the first time. A few research has been done on these metabolites so far. Another species, Turbo coronatus exists in Iran. The main aim of the current project was to investigate some biological effects of the crude extract of Turbo coronatus from the Persian Gulf . Materials and methods: In this study, 18 rats were selected in three groups including the control group. The experimental groups received ½ and 1/3 lethal doses intravenously and serum levels of liver and muscle enzymes, electrolytes and complete blood counts (CBC were measured after 24 hours. : The levels of liver and muscle enzymes, amylase, sodium, potassium, calcium, phosphorus, ferrous, haptoglobin, albumin and creatinine were significantly increased in experimental group compared with the control group by injection of crude extract of Turbo coronatus; however, hemoglobin, mean corpuscular volume (MCV, red blood cell count, magnesium, and glucose levels were significantly decreased in the experimental group compared with the control group. : Intravenous injection of ½ and 1/3 lethal doses of the crude extract of Turbo coronatus to rats produced rhabdomyolysis and hepatocytes injury. In addition, the crude extract injection acted as a haematoxin and decreased hemoglobin and MCV.

  12. Genomic DNA extraction method from Annona senegalensis Pers ...

    African Journals Online (AJOL)

    aghomotsegin

    2014-02-05

    SDS) or cetyl-methyl ammonium bromide (CTAB). The released DNA should be protected from endogenous nuclease. Ethylenediaminetetra acetate. (EDTA) is often included in the extraction buffer to chelate magnesium ions ...

  13. Development and Application of Solid Phase Extraction Method for ...

    African Journals Online (AJOL)

    NICO

    for the addition of organic modifier, sample load volume, conditioning solvent, washing solvent and ... Solid phase extraction, polycyclic aromatic hydrocarbons, water samples, ... such as polymeric, activated carbon or silica modified with.

  14. Application of Hplc-Pda Method Using Two Different Extraction Procedures for the Determination of Alkylresorcinols in Cereals

    Directory of Open Access Journals (Sweden)

    Gailāne Natālija

    2015-09-01

    Full Text Available Cereals, especially barley, are an important source of vitamins, minerals, dietary fibre and various phytochemicals, such as alkylresorcinols (ARs. Cereal ARs are a group of phenolic lipids located in the outer parts of grain, particularly in rye and wheat, but not found in refined flour or in refined products from cereals. This study focuses on the comparison of different extraction procedures applied for the determination of the content of ARs (C15:0 - C23:0 in grain of Latvian barley genotypes. The content of ARs in 1 rye and 16 barley samples grown with different amounts of fertilier was determined by High Performance Liquid Chromatography method with Photodiode Array detection (HPLC-PDA developed by us. Two different extraction methods were compared: accelerated Soxhlet extraction and 24-hour extraction. Aside from validation of the extraction procedures, validation parameters for the HPLC-PDA based quantitation method were provided. The coefficients of variation for repeatability and intermediate precision were < 9% and < 3%, respectively. The content of ARs determined with the HPLC-PDA method in conjunction with accelerated Soxhlet extraction was up to 1.5 times higher than using 24-hour extraction. AR content varied from 2.11 ± 0.04 to 3.80 ± 0.10 mg·100 g-1 for 24-hour extraction and from 2.66 ± 0.06 to 5.70 ± 0.20 mg·100 g-1 for accelerated Soxhlet extraction, indicating the increased efficiency of this procedure in analysis of ARs.

  15. Ions extraction and collection using the RF resonance method and taking into consideration the sputtering loss

    International Nuclear Information System (INIS)

    Xie Guofeng; Wang Dewu; Ying Chuntong

    2005-01-01

    One-dimensional ions extraction and collection using the RF resonance method is studied by PIC-MCC simulation. The energy and angle distribution of extracted ions is recorded and the sputtering loss is calculated. The results show that compared with parallel electrode method, RF resonance method has advantages such as shorter extraction time, lower collision loss and sputtering loss and higher collection ratio; the extraction time and collision loss are decreased with increasing extraction voltage, but the sputtering loss increases and collection ratio decreases; collision loss is decreased with increasing magnetic field, but the sputtering loss increases and collection ratio decreases. (authors)

  16. Parameters optimization using experimental design for headspace solid phase micro-extraction analysis of short-chain chlorinated paraffins in waters under the European water framework directive.

    Science.gov (United States)

    Gandolfi, F; Malleret, L; Sergent, M; Doumenq, P

    2015-08-07

    The water framework directives (WFD 2000/60/EC and 2013/39/EU) force European countries to monitor the quality of their aquatic environment. Among the priority hazardous substances targeted by the WFD, short chain chlorinated paraffins C10-C13 (SCCPs), still represent an analytical challenge, because few laboratories are nowadays able to analyze them. Moreover, an annual average quality standards as low as 0.4μgL(-1) was set for SCCPs in surface water. Therefore, to test for compliance, the implementation of sensitive and reliable analysis method of SCCPs in water are required. The aim of this work was to address this issue by evaluating automated solid phase micro-extraction (SPME) combined on line with gas chromatography-electron capture negative ionization mass spectrometry (GC/ECNI-MS). Fiber polymer, extraction mode, ionic strength, extraction temperature and time were the most significant thermodynamic and kinetic parameters studied. To determine the suitable factors working ranges, the study of the extraction conditions was first carried out by using a classical one factor-at-a-time approach. Then a mixed level factorial 3×2(3) design was performed, in order to give rise to the most influent parameters and to estimate potential interactions effects between them. The most influent factors, i.e. extraction temperature and duration, were optimized by using a second experimental design, in order to maximize the chromatographic response. At the close of the study, a method involving headspace SPME (HS-SPME) coupled to GC/ECNI-MS is proposed. The optimum extraction conditions were sample temperature 90°C, extraction time 80min, with the PDMS 100μm fiber and desorption at 250°C during 2min. Linear response from 0.2ngmL(-1) to 10ngmL(-1) with r(2)=0.99 and limits of detection and quantification, respectively of 4pgmL(-1) and 120pgmL(-1) in MilliQ water, were achieved. The method proved to be applicable in different types of waters and show key advantages, such

  17. Hydrolysis constants of tetravalent neptunium by using solvent extraction method

    International Nuclear Information System (INIS)

    Fujiwara, K.; Kohara, Y.

    2008-01-01

    The hydrolysis constants of tetravalent neptunium (Np(IV)) were determined by solvent extraction method using thenoyltrifluoroacetone(TTA). In order to avoid colloid formation, a stock solution of carrier-free 239 Np(V) was from 243 Am milked. The valence of Np in the solution was then reduced to Np(IV) by using zinc amalgam. The hydrolysis constants (β m ) of the reactions, Np 4+ + mOH - = Np(OH) m (4-m)+ was evaluated by using distribution ratios at ionic strengths (I) = 0.1, 0.5 and 1.0. All experiments were performed in oxygen-free 0.5% H 2 -N 2 atmosphere (below 1.0 ppm of O 2 ) in a glove-box at room temperature (23 ± 2 C) to avoid oxidation of Np(IV). The β m values were extrapolated to the standard state (I = 0) by using the specific ion interaction theory (SIT), and the formation constants at I = 0 were determined to be log β 1 = 13.91 ± 0.23, log β 2 = 27.13 ± 0.15, log β 3 = 37.70 ± 0.30 and log β 4 = 46.16 ± 0.30. The ion interaction coefficients were also evaluated to be ε(NpOH 3+ , ClO 4 - ) = 0.49 ± 0.15, ε(Np(OH) 2 2+ , ClO 4 - ) = 0.35 ± 0.11, and ε(Np(OH) 3 + , ClO 4 - ) = 0.29 ± 0.15. (orig.)

  18. Hydrolysis constants of tetravalent neptunium by using solvent extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, K. [Japan Atomic Energy Agency (JAEA), Naka-gun, Ibaraki-ken (Japan); Kohara, Y. [Inspection and Development Co., Naka-gun, Ibaraki-ken (Japan)

    2008-07-01

    The hydrolysis constants of tetravalent neptunium (Np(IV)) were determined by solvent extraction method using thenoyltrifluoroacetone(TTA). In order to avoid colloid formation, a stock solution of carrier-free {sup 239}Np(V) was from {sup 243}Am milked. The valence of Np in the solution was then reduced to Np(IV) by using zinc amalgam. The hydrolysis constants ({beta}{sub m}) of the reactions, Np{sup 4+} + mOH{sup -} = Np(OH){sub m}{sup (4-m)+} was evaluated by using distribution ratios at ionic strengths (I) = 0.1, 0.5 and 1.0. All experiments were performed in oxygen-free 0.5% H{sub 2}-N{sub 2} atmosphere (below 1.0 ppm of O{sub 2}) in a glove-box at room temperature (23 {+-} 2 C) to avoid oxidation of Np(IV). The {beta}{sub m} values were extrapolated to the standard state (I = 0) by using the specific ion interaction theory (SIT), and the formation constants at I = 0 were determined to be log {beta}{sub 1} = 13.91 {+-} 0.23, log {beta}{sub 2} = 27.13 {+-} 0.15, log {beta}{sub 3} = 37.70 {+-} 0.30 and log {beta}{sub 4} = 46.16 {+-} 0.30. The ion interaction coefficients were also evaluated to be {epsilon}(NpOH{sup 3+}, ClO{sub 4}{sup -}) = 0.49 {+-} 0.15, {epsilon}(Np(OH){sub 2}{sup 2+}, ClO{sub 4}{sup -}) = 0.35 {+-} 0.11, and {epsilon}(Np(OH){sub 3}{sup +}, ClO{sub 4}{sup -}) = 0.29 {+-} 0.15. (orig.)

  19. Calculation of nuclear reaction parameters with the generator co-ordinate method and their interpretation

    International Nuclear Information System (INIS)

    Beck, R.; Mihailovic, M.V.; Poljsak, M.

    1980-05-01

    Collisions between complex nuclei are described variationally in terms of the GCM with the aim to provide an evidence that it is a manageable calculational procedure. The variational principle of Kohn and Kato is used to derive the expression for the K matrix. The space of scattering states is spanned entirely by antisymmetrized products of shell model wave functions describing separate clusters; the generator coordinate is the separation between the two shell model potentials. Scattering boundary conditions are enforced by solving an integral equation for the channel GC amplitude in each open channel separately. The main part of evaluation of collision parameters is performed by calculating double integrals of a form factor between channel GC amplitudes. A theorem about a property of the form factors is proved which allows reduction of the amount of work needed to calculate double integrals. The application of the method to the elastic 3 H to 4 He scattering has shown the feasibility of the calculation. It is shown how an analysis of calculated scattering parameters and corresponding scattering states in terms of quasibound states enables one to make a consistent comparison with experiment and to extract some knowledge of the reaction mechanism. Finally a comparative list of the calculational procedures of the GCM and RGM for reactions is made. (author)

  20. Method for 236U Determination in Seawater Using Flow Injection Extraction Chromatography and Accelerator Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Steier, Peter

    2015-01-01

    An automated analytical method implemented in a flow injection (FI) system was developed for rapid determination of 236U in 10 L seawater samples. 238U was used as a chemical yield tracer for the whole procedure, in which extraction chromatography (UTEVA) was exploited to purify uranium, after...... experimental parameters affecting the analytical effectiveness were investigated and optimized in order to achieve high chemical yields and simple and rapid analysis as well as low procedure background. Besides, the operational conditions for the target preparation prior to the AMS measurement were optimized......, on the basis of studying the coprecipitation behavior of uranium with iron hydroxide. The analytical results indicate that the developed method is simple and robust, providing satisfactory chemical yields (80−100%) and high analysis speed (4 h/sample), which could be an appealing alternative to conventional...

  1. Recommended environmental dose calculation methods and Hanford-specific parameters

    International Nuclear Information System (INIS)

    Schreckhise, R.G.; Rhoads, K.; Napier, B.A.; Ramsdell, J.V.; Davis, J.S.

    1993-03-01

    This document was developed to support the Hanford Environmental Dose overview Panel (HEDOP). The Panel is responsible for reviewing all assessments of potential doses received by humans and other biota resulting from the actual or possible environmental releases of radioactive and other hazardous materials from facilities and/or operations belonging to the US Department of Energy on the Hanford Site in south-central Washington. This document serves as a guide to be used for developing estimates of potential radiation doses, or other measures of risk or health impacts, to people and other biota in the environs on and around the Hanford Site. It provides information to develop technically sound estimates of exposure (i.e., potential or actual) to humans or other biotic receptors that could result from the environmental transport of potentially harmful materials that have been, or could be, released from Hanford operations or facilities. Parameter values and information that are specific to the Hanford environs as well as other supporting material are included in this document

  2. Recommended environmental dose calculation methods and Hanford-specific parameters

    Energy Technology Data Exchange (ETDEWEB)

    Schreckhise, R.G.; Rhoads, K.; Napier, B.A.; Ramsdell, J.V. (Pacific Northwest Lab., Richland, WA (United States)); Davis, J.S. (Westinghouse Hanford Co., Richland, WA (United States))

    1993-03-01

    This document was developed to support the Hanford Environmental Dose overview Panel (HEDOP). The Panel is responsible for reviewing all assessments of potential doses received by humans and other biota resulting from the actual or possible environmental releases of radioactive and other hazardous materials from facilities and/or operations belonging to the US Department of Energy on the Hanford Site in south-central Washington. This document serves as a guide to be used for developing estimates of potential radiation doses, or other measures of risk or health impacts, to people and other biota in the environs on and around the Hanford Site. It provides information to develop technically sound estimates of exposure (i.e., potential or actual) to humans or other biotic receptors that could result from the environmental transport of potentially harmful materials that have been, or could be, released from Hanford operations or facilities. Parameter values and information that are specific to the Hanford environs as well as other supporting material are included in this document.

  3. Basic technical parameters of magnetometers with ferromagnetic transducers and a method to define them

    International Nuclear Information System (INIS)

    Nagiello, Z.

    1980-01-01

    The basic technical parameters of magnetometers with ferromagnetic transducers and measuring methods to define these parameters have been discussed. Special attention was paid to factors which essentially affect the inaccuracy of these measuring instruments. (author)

  4. Solvent and extraction methods effects on the quality of eel ( Anguilla bicolor ) oil

    International Nuclear Information System (INIS)

    Sasongko, H; Efendi, N R; Farida, Y; Amartiwi, T; Rahmawati, A A; Wicaksono, A; Budihardjo, A; Sugiyarto

    2017-01-01

    Eel ( Anguilla bicolor) is a general fish consumption in many countries, especially Japan, China, Germany, and France. Besides its vitamin rich, eel oil is also known to contain fatty acids that are necessary for pharmaceutical purposes and as food a supplement. This research was aimed to evaluate the quality of eel oil by different solvent and extraction methods. In this study, fresh eels were extracted using maceration and reflux methods.Chloroform was used as the solvent in the maceration while water used in the reflux method. The oil quality was examined based on the Official Methods of Analysis of the Association of Official Analytical Chemist (AOAC).The result showed that the yield of eel oil using maceration method was 5.44% ± 0.64 with a specific gravity of 0.915 g/mL, while reflux method obtained the yield of 5.33 % ± 0.84 and specific gravity of 0.8575 g/mL. The physicochemical parameters of oil quality used in this study were acid, peroxide, saponification, and iodine value. The maceration method obtained the acid value of 17.389 mgKOH/g, the peroxide value of 7.021meqO 2 /kg, the saponification value of 111.16mgKOH/g, and the iodine value of 65.14 WIJS. While the reflux method produced the acid value of 9.116 mgKOH/g, the peroxide value of 6.088 meqO 2 /kg, the saponification value of 70 mgKOH/g, and the iodine value of 87.74 WIJS. (paper)

  5. Extraction chromatographic method for the separation of actinides and lanthanides using EDHBA grafted AXAD-16 polymer

    Energy Technology Data Exchange (ETDEWEB)

    Akhila Maheswari, M.; Subramanian, M.S. [Department of Chemistry, Indian Institute of Technology, Chennai (India)

    2005-02-15

    A new extraction chromatographic method has been developed by grafting chloromethylated polymer support with 4-ethoxy-N,N-dihexylbutanamide (EDHBA), for the selective extraction of U(VI), Th(IV), La(III) and Nd(III) from highly acidic matrices. The developed grafted polymer has been characterized using {sup 13}C-CPMAS NMR spectroscopy, FT-NIR spectroscopy and also by CHN elemental analysis. The water regaining capacity of the grafted polymer is studied by TGA measurements and the active participation of the amide moiety towards metal ion complexation has been confirmed by Far IR spectroscopy. For the quantitative extraction of metal ions to the resin phase, various physico-chemical parameters are optimized by both static and dynamic methods. The developed amide grafted polymeric matrix shows good distribution ratio values even at high acidities, with the maximum metal sorption capacity values being 0.36, 0.69, 0.32 and 0.42mmolg{sup -1} for U(VI), Th(IV), La(III) and Nd(III), respectively, at 6M HNO{sub 3} medium. The kinetics of metal ion phase equilibration is found to be moderately fast, with t{sub 1/2} values of <6min, for all the analytes of interest. The limits of analyte quantification (LOQ) using the developed method are in the range of 15-30{mu}gL{sup -1}. Moreover, the sequential separation of the sorbed actinides and lanthanides could be achieved by first eluting with 100mL of distilled water (for actinides) followed by elution with 20mL of 0.1M EDTA (for lanthanides). The selectivity behavior and the practical applicability of the developed resin are tested using synthetic low level nuclear reprocessing mixtures and also with monazite sand. The analytical data are within 3.8% relative standard deviation, reflecting the reproducibility and reliability of the developed method.

  6. OPTIMIZATION OF HIBISCUS SABDARIFFA L. (ROSELLE ANTHOCYANIN AQUEOUS-ETHANOL EXTRACTION PARAMETERS USING RESPONSE SURFACE METHODOLOGY

    Directory of Open Access Journals (Sweden)

    ANILÚ MIRANDA-MEDINA

    2018-03-01

    Full Text Available Anthocyanins along with protocatechuic acid and quercetin have been recognized as bioactive compounds in Hibiscus sabdariffa L. aqueous extracts. Characteristic anthocyanin absorption in the visible region makes their quantification possible without the interference of the other two compounds, and also can favor its potential application as an alternative to organic-based dye sensitized solar cell, in various forms. In order to optimize measurable factors linked to the extraction of these flavonoids, an optimization was performed using a Box-Behnken experimental design and response surface methodology (RSM. Three levels of ethanol concentration, temperature and solid-solvent ratio (SSR were investigated. The optimization model showed that with 96 % EtOH, 65 °C, and 1:50 SSR, the highest anthocyanin concentration of 150 mg/100 g was obtained.

  7. Gas flow parameter determination by molecular beam method

    International Nuclear Information System (INIS)

    Zarvin, A.E.; Sharafutdinov, R.G.

    1977-01-01

    This paper describes a molecular-beam system intended for studying nonequilibrium processes in supersonic rarefied gas flows. The system represented is a small molecular beam source placed inside the low intensity wind tunnel of the Institute of Thermophysics, Siberian Branch of the USSR Academy of Sciences. The time-of-flight method is used for measuring molecular velocity distribution functions on molecular beam axis. (Auth.)

  8. Effect of soil contaminant extraction method in determining toxicity using the Microtox(reg.) assay

    International Nuclear Information System (INIS)

    Harkey, G.A.; Young, T.M.

    2000-01-01

    This project examined the influence of different extraction methods on the measured toxicity of contaminated soils collected from manufactured gas plant (MGP) sites differing in soil composition and contaminant concentration. Aged soils from a number of MGP sites were extracted using a saline solution, supercritical fluid extraction (SFE), and Soxhlet extraction. Toxicity was assessed using two forms of Microtox tests: acute aqueous tests on saline and SFE soil extracts and solid-phase tests (SPTs) on soil particles. Microtox SPTs were performed on soils before and after SFE to determine resulting toxicity reduction. Three hypotheses were tested: (1) Toxicity of soil extracts is related to contaminant concentrations of the extracts, (2) measured toxicity significantly decreases with less vigorous methods of extraction, and (3) supercritical fluid extractability correlates with measured toxicity. The EC50s for SPTs performed before and after SFE were not different for some soils but were significantly greater after extraction for other soils tested. The most significant toxicity reductions were observed for soils exhibiting the highest toxicity in both preextraction SPTs and acute aqueous tests. Acute Microtox tests performed on SFE extracts showed significantly lower EC50s than those reported from saline-based extraction procedures. Toxicity of the soils measured by Microtox SPTs was strongly correlated with both SFE efficiency and measures of contaminant aging. Data from this project provide evidence of sequestration and reduced availability of polycyclic aromatic hydrocarbons (PAHs) from soils extracted via physiologically based procedures compared to vigorous physical extraction protocols

  9. Analytic calculation of radio emission from parametrized extensive air showers: A tool to extract shower parameters

    Science.gov (United States)

    Scholten, O.; Trinh, T. N. G.; de Vries, K. D.; Hare, B. M.

    2018-01-01

    The radio intensity and polarization footprint of a cosmic-ray induced extensive air shower is determined by the time-dependent structure of the current distribution residing in the plasma cloud at the shower front. In turn, the time dependence of the integrated charge-current distribution in the plasma cloud, the longitudinal shower structure, is determined by interesting physics which one would like to extract, such as the location and multiplicity of the primary cosmic-ray collision or the values of electric fields in the atmosphere during thunderstorms. To extract the structure of a shower from its footprint requires solving a complicated inverse problem. For this purpose we have developed a code that semianalytically calculates the radio footprint of an extensive air shower given an arbitrary longitudinal structure. This code can be used in an optimization procedure to extract the optimal longitudinal shower structure given a radio footprint. On the basis of air-shower universality we propose a simple parametrization of the structure of the plasma cloud. This parametrization is based on the results of Monte Carlo shower simulations. Deriving the parametrization also teaches which aspects of the plasma cloud are important for understanding the features seen in the radio-emission footprint. The calculated radio footprints are compared with microscopic CoREAS simulations.

  10. Effects of a triplex mixture of Peganum harmala, Rhus coriaria, and Urtica dioica aqueous extracts on metabolic and histological parameters in diabetic rats.

    Science.gov (United States)

    Abedi Gaballu, Fereydoon; Abedi Gaballu, Yousef; Moazenzade Khyavy, Omid; Mardomi, Alireza; Ghahremanzadeh, Kazem; Shokouhi, Behrooz; Mamandy, Himan

    2015-08-01

    Several therapeutic effects such as antioxidant and blood glucose-lowering activities have been reported for Peganum harmala L (Zygophyllaceae) (PH) seeds, Rhus coriaria L (Anacardiaceae) (RC) fruits, and Urtica dioica L (Urticaceae) (UD) leaves. This study investigates the effects of a triplex mixture (1:1:1) of these medicinal plants on metabolic and histological parameters in diabetic rats. Aqueous extracts of PH, RC and UD were administered as either monotherapy or in combination at a final dose of 200 mg/kg to alloxan-induced diabetic rats by daily gavage. Biochemical parameters including blood glucose, liver function-related enzymes, lipid profile, and creatinine were estimated by spectrophotometric methods. Tissues from the liver and kidney stained with hematoxylin/eosin were histologically examined. The results obtained from the exposure groups were compared to either healthy or diabetic control groups. Compared with the diabetic control rats, all aqueous extracts (ED50 = 11.5 ± 2.57 mg/ml) led to significant decreases in the levels of ALP (1.39-2.23-fold, p < 0.05), low-density lipoprotein cholesterol (LDL-C) (1.79-3.26-fold, p < 0.05), and blood glucose (1.27-4.16-fold, p < 0.05). The serum concentrations of TG was decreased only by treatment with UD and triplex mixture (1.25- and 1.20-fold, respectively, p < 0.05). Among the studied parameters, alanine aminotransferase (ALT), LDL-C, TG, and creatinine recovered to healthy control levels after 4 weeks of treatment with the extract mixture. This study showed that PH, RC, and UD extracts, especially their combination, had significant antidiabetic, hypolipidemic, and liver and renal damage recovering effects.

  11. Human DNA Extraction by Two Extraction Methods for Forensic Typification from Human Feces on FTA Paper

    Directory of Open Access Journals (Sweden)

    Shirleny Monserrat Sandoval-Arias

    2014-11-01

    Full Text Available The identification of suspects in criminal investigations has been facilitated since DNA test are executed on different samples. The application of this technology for forensic typification from human fecal samples still presents complications therefore this research evaluated two DNA extraction protocols with modifications to determine that of major efficiency. Organic extractions and extractions using the commercial kit “IQTM DNA Casework Sample Kit for Maxwell ® 16” on FTA portions of 4cm2 and 1cm2 impregnated with feces from the same individual were done to accomplish the objective. In all the assays the results were useful, however; the best forensic typification (by the electropherogram characteristics was obtained by using the commercial kit in an area of 1 cm2 of FTA paper impregnated in a 1:4 dilution.

  12. Parameter estimation for hydrogen analysis by using transport method

    International Nuclear Information System (INIS)

    Selvi, S.; Can, N.

    1992-01-01

    A transport method is described which reduces greatly the number of calibration standards needed for hydrogen analysis by neutron induced prompt γ-rays. The counts in the photopeaks from neutron capture in hydrogen for various standard concentrations, the distribution of the source neutron rate entering the thermal group and the reaction rates in the samples are investigated theoretically using 100 energy group cross sections and experimental 252 Cf spectra for a test configuration. Comparison of theoretical results with those measured from the test configuration shows good agreement. (author)

  13. Potato tuber proteomics: Comparison of two complementary extraction methods designed for 2-DE of acidic proteins

    NARCIS (Netherlands)

    Delaplace, P.; Wal, van der F.; Dierick, J.F.; Cordewener, J.H.G.; Fauconnier, M.L.; Jardin, du P.; America, A.H.P.

    2006-01-01

    Two protein extraction procedures were tested in order to remove interfering compounds prior to 2-DE of potato tubers. These methods using SDS lysis buffer and phenol-phase extraction were compared regarding the quality of the resulting 2-D gel. While the resolution of SDS extracts on

  14. Comparison of nine DNA extraction methods for the diagnosis of bovine tuberculosis by real time PCR

    OpenAIRE

    Moura, André; Hodon, Mikael Arrais; Soares Filho, Paulo Martins; Issa, Marina de Azevedo; Oliveira, Ana Paula Ferreira de; Fonseca Júnior, Antônio Augusto

    2016-01-01

    ABSTRACT: Bovine tuberculosis is an infectious disease with a high impact on the cattle industry, particularly in developing countries. PCR is a very sensitive method for detection of infectious agents, but the sensitivity of molecular diagnosis is largely dependent on the efficiency of the DNA extraction methods. The objective of this study was to evaluate DNA extraction methods for direct detection of Mycobacterium bovis in bovine tissue. Nine commercial kits for DNA extraction were evalua...

  15. Comparison of the methods for tissue triiodothyronine T(3) extraction and subsequent radioimmunoassay

    International Nuclear Information System (INIS)

    Takaishi, M.; Miyachi, Y.; Aoki, M.; Shishiba, Y.; Asahi Life Foundation, Tokyo

    1978-01-01

    Although there have been various reports on tissue T 3 concentration, the examination of the quality of radioimmunoassay has not been available. In the present study, we tried to determine whether the available methods for T 3 extraction are adequate for the various methods of T 3 radioimmunoassays used. T 3 was extracted from liver by ethanol extraction or by acid butanol extraction (Flock's method) and the extract was applied to radioimmunoassay either by Seralute T 3 column, ANS-double antibody or the ANS-charcoal method. The values of T 3 were compared with those obtained by isotope-equilibration method. The dilution curve of ethanol extract was not parallel with that of the standard in ANS-charcoal or ANS-double antibody technique. When the extract was tested by Seralate method, the dilution curve was parallel to the standard, whereas the T 3 value obtained with this method was two-fold higher than that with the isotope equilibration technique. The analysis of the ethanol extract suggested that the lipid extracted by ethanol interfered with the assay. The acid butanol extract when tested either by the ANS-double antibody or Seralate method, showed parallelism to the standard curve and gave T 3 values almost identical with those by the isotope-equilibration method. When tested by ANS-charcoal method, the dilution curve of the acid butanol extract was not parallel to the standard. Thus, to obtain reliable results, tissue extraction by Flock's method and subsequent T 3 radioimmunoassay by either ANS-double antibody or Seralate T 3 method are recommended. (author)

  16. Improvement of extraction method of coagulation active components from Moringa oleifera seed

    OpenAIRE

    Okuda, Tetsuji; Baes, Aloysius U.; Nishijima, Wataru; Okada, Mitsumasa

    1999-01-01

    A new method for the extraction of the active coagulation component from Moringa oleifera seeds was developed and compared with the ordinary water extraction method (MOC–DW). In the new method, 1.0 mol l-1 solution of sodium chloride (MOC–SC) and other salts were used for extraction of the active coagulation component. Batch coagulation experiments were conducted using 500 ml of low turbid water (50 NTU). Coagulation efficiencies were evaluated based on the dosage required to remove kaolinite...

  17. Standard Test Method for Determining the Linearity of a Photovoltaic Device Parameter with Respect To a Test Parameter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method determines the degree of linearity of a photovoltaic device parameter with respect to a test parameter, for example, short-circuit current with respect to irradiance. 1.2 The linearity determined by this test method applies only at the time of testing, and implies no past or future performance level. 1.3 This test method applies only to non-concentrator terrestrial photovoltaic devices. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  18. A rapid and low-cost DNA extraction method for isolating ...

    African Journals Online (AJOL)

    The price of commercial DNA extraction methods makes the routine use of polymerase chain reaction amplification (PCR) based methods rather costly for scientists in developing countries. A guanidium thiocayante-based DNA extraction method was investigated in this study for the isolation of Escherichia coli (E. coli) DNA ...

  19. Extraction method for the determination of inorganic iodides in Rose Bengal labelled with 131I

    International Nuclear Information System (INIS)

    Lengyel, J.; Krtil, J.; Vecernik, J.

    1982-01-01

    An extraction method for the determination of inorganic iodides in Rose Bengal preparations labelled with 131 I is described. The method is based on the quantitative extraction of Rose Bengal into chloroform from acidic medium while the inorganic iodides remain in the aqueous phase. The method is simple, rapid, and reproducible. (author)

  20. Impact of meteorological parameters on extracted landfill gas composition and flow

    DEFF Research Database (Denmark)

    Fathi Aghdam, Ehsan; Scheutz, Charlotte; Kjeldsen, Peter

    2018-01-01

    The objective of this study was to investigate the impact of four pre-selected meteorological parameters (barometric pressure, wind speed, ambient temperature and solar radiation) on recovered landfill gas (LFG) flow, methane (CH4) content of the LFG and the recovered CH4 flow by performing...

  1. An investigation into the equivalent parameter method for homogeneous transport equivalent parameters for use in fast reactor control assemblies

    International Nuclear Information System (INIS)

    Tullett, J.D.

    1990-01-01

    P Benoist has developed a method for calculating cross-sections for Fast Reactor control rods and their followers described by a single homogenised region (the Equivalent Parameter Method). When used in a diffusion theory calculation, these equivalent cross-sections should give the same rod worth as one would obtain from a transport theory calculation with a heterogeneous description of the control rod and the follower. In this report, Benoist's theory is described, and a comprehensive set of tests is presented. These tests show that the method gives very good results over a range of geometries and control rod positions for a model fast reactor core. (author)

  2. Optimization of Parameters for Biosynthesis of Silver Nanoparticles Using Leaf Extract of Aegle marmelos

    Directory of Open Access Journals (Sweden)

    JohnSamuel Godwin Christopher

    2015-10-01

    Full Text Available ABSTRACTThe aim of this study was to optimize the biosynthesis of silver nanoparticles using leaves ofAegle marmelos as the primary source. The optimal reaction medium comprised 2:1 concentration of leaf extract and 6mM concentration of silver nitrate solution (pH 7. The biosynthesized silver nanoparticles were confirmed by UV-Vis spectroscopy at 420 nm, XRD and FTIR analysis. The antimicrobial properties of silver nanoparticles were confirmed withBacillus subtilis andPseudomonas aeruginosa.

  3. [Hemostatic system parameters of placental extracts in normal pregnancy and severe preeclampsia].

    Science.gov (United States)

    López-Ramírez, Ysabel; Carvajal, Zoila; Arocha-Piñango, Carmen Luisa

    2006-09-01

    To better understand the role of the hemostatic mechanism in preeclampsia, placental extracts obtained from 26 normal pregnant women (NP) and 12 patients with severe pre-eclampsia (SPE) were analyzed to determine thrombomodulin (TM), tissue factor (TF), tissue-type plasminogen activator (tPA), plasminogen activator inhibitor (PAI) 1 and 2, and TF pathway inhibitor (TFPI). The results showed similar concentrations of TF, TM and PAI-2 in both groups, while tPA increased no significantly and TFPI and PAI-1 increased significantly in SPE placentas.

  4. Sample preparation method for the combined extraction of ethyl glucuronide and drugs of abuse in hair.

    Science.gov (United States)

    Meier, Ulf; Briellmann, Thomas; Scheurer, Eva; Dussy, Franz

    2018-04-01

    Often in hair analysis, a small hair sample is available while the analysis of a multitude of structurally diverse substances with different concentration ranges is demanded. The analysis of the different substances often requires different sample preparation methods, increasing the amount of required hair sample. When segmental hair analysis is necessary, the amount of hair sample needed is further increased. Therefore, the required sample amount for a full analysis can quickly exceed what is available. To combat this problem, a method for the combined hair sample preparation using a single extraction procedure for analysis of ethyl glucuronide with liquid chromatography-multistage fragmentation mass spectrometry/multiple reaction monitoring (LC-MS 3 /MRM) and common drugs of abuse with LC-MRM was developed. The combined sample preparation is achieved by separating ethyl glucuronide from the drugs of abuse into separate extracts by fractionation in the solid-phase extraction step during sample clean-up. A full validation for all substances for the parameters selectivity, linearity, limit of detection, limit of quantification, accuracy, precision, matrix effects, and recovery was successfully completed. The following drugs of abuse were included in the method: Amphetamine; methamphetamine; 3,4-methylenedioxy-N-methylamphetamine (MDMA); 3,4-methylenedioxyamphetamine (MDA); 3,4-methylenedioxy-N-ethylamphetamine (MDE); morphine; 6-monoacetylmorphine; codeine; acetylcodeine; cocaine; benzoylecgonine; norcocaine; cocaethylene; methadone; 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and methylphenidate. In conclusion, as only 1 sample preparation is needed with 1 aliquot of hair, the presented sample preparation allows an optimal analysis of both ethyl glucuronide and of the drugs of abuse, even when the sample amount is a limiting factor. Copyright © 2017 John Wiley & Sons, Ltd.

  5. Applying a weighted random forests method to extract karst sinkholes from LiDAR data

    Science.gov (United States)

    Zhu, Junfeng; Pierskalla, William P.

    2016-02-01

    Detailed mapping of sinkholes provides critical information for mitigating sinkhole hazards and understanding groundwater and surface water interactions in karst terrains. LiDAR (Light Detection and Ranging) measures the earth's surface in high-resolution and high-density and has shown great potentials to drastically improve locating and delineating sinkholes. However, processing LiDAR data to extract sinkholes requires separating sinkholes from other depressions, which can be laborious because of the sheer number of the depressions commonly generated from LiDAR data. In this study, we applied the random forests, a machine learning method, to automatically separate sinkholes from other depressions in a karst region in central Kentucky. The sinkhole-extraction random forest was grown on a training dataset built from an area where LiDAR-derived depressions were manually classified through a visual inspection and field verification process. Based on the geometry of depressions, as well as natural and human factors related to sinkholes, 11 parameters were selected as predictive variables to form the dataset. Because the training dataset was imbalanced with the majority of depressions being non-sinkholes, a weighted random forests method was used to improve the accuracy of predicting sinkholes. The weighted random forest achieved an average accuracy of 89.95% for the training dataset, demonstrating that the random forest can be an effective sinkhole classifier. Testing of the random forest in another area, however, resulted in moderate success with an average accuracy rate of 73.96%. This study suggests that an automatic sinkhole extraction procedure like the random forest classifier can significantly reduce time and labor costs and makes its more tractable to map sinkholes using LiDAR data for large areas. However, the random forests method cannot totally replace manual procedures, such as visual inspection and field verification.

  6. Critical assessment of extracellular polymeric substances extraction methods from mixed culture biomass

    DEFF Research Database (Denmark)

    Pellicer i Nàcher, Carles; Domingo Felez, Carlos; Mutlu, Ayten Gizem

    2013-01-01

    . This study presents a rigorous and critical assessment of existing physical and chemical EPS extraction methods applied to mixed-culture biomass samples (nitrifying, nitritation-anammox, and activated sludge biomass). A novel fluorescence-based method was developed and calibrated to quantify the lysis...... potential of different EPS extraction protocols. We concluded that commonly used methods to assess cell lysis (DNA concentrations or G6PDH activities in EPS extracts) do not correlate with cell viability. Furthermore, we discovered that the presence of certain chemicals in EPS extracts results in severe...... underestimation of protein and carbohydrate concentrations by using standard analytical methods. Keeping both maximum EPS extraction yields and minimal biomass lysis as criteria, it was identified a sonication-based extraction method as the best to determine and compare tightly-bound EPS fractions in different...

  7. Chemical composition and antibacterial activity of Cordia verbenacea extracts obtained by different methods.

    Science.gov (United States)

    Michielin, Eliane M Z; Salvador, Ana A; Riehl, Carlos A S; Smânia, Artur; Smânia, Elza F A; Ferreira, Sandra R S

    2009-12-01

    The present study describes the chemical composition and the antibacterial activity of extracts from Cordia verbenacea DC (Borraginaceae), a traditional medicinal plant that grows widely along the southeastern coast of Brazil. The extracts were obtained using different extraction techniques: high-pressure operations and low-pressure methods. The high-pressure technique was applied to obtain C. verbenacea extracts using pure CO(2) and CO(2) with co-solvent at pressures up to 30MPa and temperatures of 30, 40 and 50 degrees C. Organic solvents such as n-hexane, ethyl acetate, ethanol, acetone and dichloromethane were used to obtain extracts by low-pressure processes. The antibacterial activity of the extracts was also subjected to screening against four strains of bacteria using the agar dilution method. The extraction yields were up to 5.0% w/w and up to 8.6% w/w for supercritical fluid extraction with pure CO(2) and with ethyl acetate as co-solvent, respectively, while the low-pressure extraction indicates yields up to 24.0% w/w in the soxhlet extraction using water and aqueous mixture with 50% ethanol as solvents. The inhibitory activity of the extracts in gram-positive bacteria was significantly higher than in gram-negative. The quantification and the identification of the extracts recovered were accomplished using GC/MS analysis. The most important components identified in the extract were artemetin, beta-sitosterol, alpha-humulene and beta-caryophyllene, among others.

  8. Extraction method for high free radical scavenging activity of Siamese neem tree flowers

    Directory of Open Access Journals (Sweden)

    Worarat Chaisawangwong

    2009-10-01

    Full Text Available Siamese neem tree (Azadirachta indica A. Juss. var. siamensis Valeton is a medicinal plant found in Thailand. Youngleaves and young flowers of this plant are commonly consumed as a bitter tonic vegetable. The flowers are also used fortreatment of fever. The flower extract has been reported to exhibit in vitro free radical scavenging activity and can inhibitlipid peroxidation of bronchogenic cancer cell line. Active compounds in the flowers are flavonoids such as rutin andquercetin. The content of these compounds in the crude extract depends on the method of extraction. Therefore, the appropriateextraction method promoting high yield of total flavonoids and high free radical scavenging activity was investigated inthis study. Six different extraction methods, i.e. maceration, percolation, decoction, soxhlet extraction, ultrasonic extraction(UE, and microwave assisted extraction (MA were carried out for extracting dried powder of Siamese neem tree young flowers. The solvent used for maceration, percolation, and soxhlet extraction was 50% ethanol, while distilled water was used for decoction and MA, and both solvents were used for UE. The content of crude extract, free radical scavenging activity, and total flavonoids content of each extract were investigated and compared. Comparing the various extraction methods, decoction provided an extract containing a high amount of total flavonoids (17.54 mgRE/g extract and promoting the highest scavenging activity at EC50 11.36 g/ml. Decoction is also simple, cheap, and convenient and could be used in developing countries. Thus, it should be the recommended extraction method for the flowers of Siamese neem tree for furtherdevelopment of antioxidant pharmaceutical preparations.

  9. Direct Extraction of InP/GaAsSb/InP DHBT Equivalent-Circuit Elements From S-Parameters Measured at Cut-Off and Normal Bias Conditions

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Leblanc, Rémy; Poulain, Julien

    2016-01-01

    A unique direct parameter extraction method for the small-signal equivalent-circuit model of InP/GaAsSb/InP double heterojunction bipolar transistors (DHBTs) is presented. $S$-parameters measured at cut-off bias are used, at first, to extract the distribution factor $X_{0}$ for the base-collector......A unique direct parameter extraction method for the small-signal equivalent-circuit model of InP/GaAsSb/InP double heterojunction bipolar transistors (DHBTs) is presented. $S$-parameters measured at cut-off bias are used, at first, to extract the distribution factor $X_{0}$ for the base......-collector capacitance at zero collector current and the collector-to-emitter overlap capacitance $C_{ceo}$ present in InP DHBT devices. Low-frequency $S$-parameters measured at normal bias conditions then allows the extraction of the external access resistances $R_{bx}$, $R_{e}$, and $R_{cx}$ as well as the intrinsic...

  10. An accurate method for the determination of unlike potential parameters from thermal diffusion data

    International Nuclear Information System (INIS)

    El-Geubeily, S.

    1997-01-01

    A new method is introduced by means of which the unlike intermolecular potential parameters can be determined from the experimental measurements of the thermal diffusion factor as a function of temperature. The method proved to be easy, accurate, and applicable two-, three-, and four-parameter potential functions whose collision integrals are available. The potential parameters computed by this method are found to provide a faith full representation of the thermal diffusion data under consideration. 3 figs., 4 tabs

  11. A method for efficient extraction of rotifers (Rotifera) from soils

    Czech Academy of Sciences Publication Activity Database

    Devetter, Miloslav

    2010-01-01

    Roč. 53, č. 2 (2010), s. 115-118 ISSN 0031-4056 R&D Projects: GA ČR(CZ) GP206/06/P405 Institutional research plan: CEZ:AV0Z60660521 Keywords : soil rotifers * Bdelloids * quantitative extraction Subject RIV: EH - Ecology, Behaviour Impact factor: 1.474, year: 2010

  12. An improved method of DNA extraction from plants for pathogen ...

    African Journals Online (AJOL)

    Polymerase chain reaction (PCR)-based applications in plant molecular biology and molecular diagnostics for plant pathogens require good quality DNA for reliable and reproducible results. Leaf tissue is often the choice for DNA extraction, but the use of other sources such as tubers, stems, or seeds, is not uncommon.

  13. comparison of protein extraction methods for the leaves of ficus

    African Journals Online (AJOL)

    F. I. Abdullah

    2017-05-01

    May 1, 2017 ... extraction technique is highly relied on the protein structure and its chemical characteristics. ..... EDTA, 1% Triton X 100, 80% glycerol, 1M DTT and distilled water) and vortexed ..... prot5438, doi : 10.1101/pdb.prot5438.

  14. Efficient method for the extraction of genomic DNA from wormwood ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-09-17

    Sep 17, 2008 ... DNA is extracted from plant material it will also contain. *Corresponding author. ... an important issue in the field of plant molecular biology. Various plants ..... An excellent guide to over 500 of the more well known medicinal ...

  15. The effect of aqueous extract of Avicennia marina (Forsk. Vierh. leaves on liver enzymes' activity, oxidative stress parameters and liver histopathology in male diabetic rats

    Directory of Open Access Journals (Sweden)

    Akram Hamzevi

    2017-12-01

    Full Text Available Background: Avicennia marina has antioxidant and anti-diabetic properties. This study was conducted to examine the effect of aqueous extract of A. marina on liver enzymes' activity, oxidative stress parameters and liver histopathology in diabetic rats. Materials and Methods: In this experimental study, 28 male rats were allocated into the equal groups of control, diabetic control and experimental diabetic 1 and 2. The diabetes in diabetic control and experimental diabetic groups was induced using an intraperitoneal injection of 120 mg/kg alloxan. The experimental diabetic groups received the aqueous extract of A. marina (100 and 200 mg/kg, i.p. in alternate days for one month. Sterile distilled water was injected to the animals of control and diabetic control groups. At the end of the treatment period, serum levels of ALT, AST, GGT and ALP were measured. Then, levels of SOD, GST, CAT and MDA were measured in the liver tissue. The liver sections were prepared and examined by an optical microscope. Results: Results showed that administration of the A. marina extract (100 and 300 mg/kg, ip to the diabetic rats significantly decreased the serum levels of liver enzymes and tissue level of MDA. Also, the activity of the liver tissue's antioxidant enzymes was increased (P<0.05. The A. marina extract dose-dependently decreased liver damages in diabetic rats. Conclusion: Administration of the A. marina extract improves liver tissue oxidative stress indices and decreases the serum level of liver enzymes. Also, A. marina extract improves liver tissue injuries induced by diabetes.

  16. A new method for microwave assisted ethanolic extraction of Mentha rotundifolia bioactive terpenoids.

    Science.gov (United States)

    García-Sarrió, María Jesús; Sanz, María Luz; Sanz, Jesús; González-Coloma, Azucena; Cristina Soria, Ana

    2018-04-14

    A new microwave-assisted extraction (MAE) method using ethanol as solvent has been optimized by means of a Box-Behnken experimental design for the enhanced extraction of bioactive terpenoids from Mentha rotundifolia leaves; 100°C, 5 min, 1.125 g dry sample: 10 mL solvent and a single extraction cycle were selected as optimal conditions. Improved performance of MAE method in terms of extraction yield and/or reproducibility over conventional solid-liquid extraction and ultrasound assisted extraction was also previously assessed. A comprehensive characterization of MAE extracts was carried out by GC-MS. A total of 46 compounds, mostly terpenoids, were identified; piperitenone oxide and piperitenone were the major compounds determined. Several neophytadiene isomers were also detected for the first time in MAE extracts. Different procedures (solid-phase extraction and activated charcoal (AC) treatment) were also evaluated for clean-up of MAE extracts, with AC providing the highest enrichment in bioactive terpenoids. Finally, the MAE method here developed is shown as a green, fast, efficient and reproducible liquid extraction methodology to obtain M. rotundifolia bioactive extracts for further application, among others, as food preservatives. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A nonlinear model for frequency dispersion and DC intrinsic parameter extraction for GaN-based HEMT

    Science.gov (United States)

    Nguyen, Tung The-Lam; Kim, Sam-Dong

    2017-11-01

    We propose in this study a practical nonlinear model for the AlGaN/GaN high electron mobility transistors (HEMTs) to extract DC intrinsic transconductance (gmDC), output conductance (gdsDC), and electron mobility from the intrinsic parameter set measured at high frequencies. An excellent agreement in I-V characteristics of the model with a fitting error of 0.11% enables us successfully extract the gmDC, gdsDC, and the total transconductance dispersion. For this model, we also present a reliable analysis scheme wherein the frequency dispersion effect due regional surface states in AlGaN/GaN HEMTs is taken into account under various bias conditions.

  18. Method of reduction of diagnostic parameters during observation on the example of a combustion engine

    Directory of Open Access Journals (Sweden)

    Orczyk Malgorzata

    2017-01-01

    Full Text Available The article presents a method of selecting diagnostic parameters which map the process of damaging the object. This method consists in calculating, during the observation, the correlation coefficient between the intensity of damage and the individual diagnostic parameters; and discarding of those parameters whose correlation coefficient values are outside of the narrowest confidence interval of the correlation coefficient. The characteristic feature of this method is that the parameters are reduced during the diagnostic experiment. The essence of the proposed method is illustrated by the vibration diagnosis of an internal combustion engine.

  19. Phase Modulation Method for Control Systems of Rotary Machine Parameters

    Directory of Open Access Journals (Sweden)

    V. V. Sychev

    2014-01-01

    Full Text Available Traditionally, vibration-based diagnostics takes the main place in a large complex of technical control means of rotary machine operation. It allows us to control the onset of extreme limit states of operating construction and its elements. However, vibration-based diagnostics is incapable to provide differentiated information about the condition of particular units, type of fault and point of its occurrence.From the practical experience of optoelectronic sensors development, methods of phase coding information about the behavior of the investigated object are known. They allow us to overcome the abovementioned disadvantage of vibration-based diagnostics through the modulation of the reflected radiation from the object. This phase modulation is performed with the image analyzers, in which the modulating raster (alternating transparent and nontransparent sectors is designed so, that the carrier frequency of oscillations is absent (suppressed in frequency spectrum, and all useful information can be found in the side frequencies.Carrier frequency suppression appears for two complete turns of the modulating raster. Each time during this process oscillations have a 180° phase shift (hop relatively to the initial oscillation on the boundary of each turn. It leads to a substantial increase in signal/noise ratio and possibility to conduct high-accuracy diagnostics.The principle of the pseudo inversion is used for measurements to suppress an adverse effect of various factors in dynamic control system. For this principle the leaving and returned beams practically go on the same way with small spatial shift. This shift occurs then the leaving beam reflects from a basic surface and the reflected – from the measured surface of the object. Therefore the measurements become insensitive to any other errors of system, except relative position of system «model-object».The main advantages of such measurements are the following:- system steadiness to error

  20. Signal shape registration in the JINR synchrophasotron slowly extracted beam parameter control system

    International Nuclear Information System (INIS)

    Volkov, V.I.; Kulikov, I.I.; Romanov, S.V.

    1982-01-01

    Signal shape registration in the JINR synchrophasotron slowly estracted beam parameter control system on-line with the ES-1010 computer is described. 32 input signals can be connected to the registrator. The maximum measurement rate of signal shape registration is about 38 kHz. The registrator consists of 32-channel analog multiplexer, 10-bit analog-to-digital converter, 1024-word buffer memory and control circuits. For information representation the colour TV monitor is used

  1. Iterative method of the parameter variation for solution of nonlinear functional equations

    International Nuclear Information System (INIS)

    Davidenko, D.F.

    1975-01-01

    The iteration method of parameter variation is used for solving nonlinear functional equations in Banach spaces. The authors consider some methods for numerical integration of ordinary first-order differential equations and construct the relevant iteration methods of parameter variation, both one- and multifactor. They also discuss problems of mathematical substantiation of the method, study the conditions and rate of convergence, estimate the error. The paper considers the application of the method to specific functional equations

  2. Optimization of control parameters of a hot cold controller by means of Simplex type methods

    Science.gov (United States)

    Porte, C.; Caron-Poussin, M.; Carot, S.; Couriol, C.; Moreno, M. Martin; Delacroix, A.

    1997-01-01

    This paper describes a hot/cold controller for regulating crystallization operations. The system was identified with a common method (the Broida method) and the parameters were obtained by the Ziegler-Nichols method. The paper shows that this empirical method will only allow a qualitative approach to regulation and that, in some instances, the parameters obtained are unreliable and therefore cannot be used to cancel variations between the set point and the actual values. Optimization methods were used to determine the regulation parameters and solve this identcation problem. It was found that the weighted centroid method was the best one. PMID:18924791

  3. Intelligent methods for the process parameter determination of plastic injection molding

    Science.gov (United States)

    Gao, Huang; Zhang, Yun; Zhou, Xundao; Li, Dequn

    2018-03-01

    Injection molding is one of the most widely used material processing methods in producing plastic products with complex geometries and high precision. The determination of process parameters is important in obtaining qualified products and maintaining product quality. This article reviews the recent studies and developments of the intelligent methods applied in the process parameter determination of injection molding. These intelligent methods are classified into three categories: Case-based reasoning methods, expert system- based methods, and data fitting and optimization methods. A framework of process parameter determination is proposed after comprehensive discussions. Finally, the conclusions and future research topics are discussed.

  4. Engineering method of calculation and choice of main parameters of the linear induction accelerator inductors

    Directory of Open Access Journals (Sweden)

    В.Т. Чемерис

    2006-04-01

    Full Text Available  There is a method of simplified calculation and design parameters choice elaborated in this article with corresponding basing for the induction system of electron-beam sterilizer on the base of linear induction accelerator taking into account the parameters of magnetic material for production of cores and parameters of pulsed voltage.

  5. Effect of resonance decays on extracted kinetic freeze-out parameters in heavy ion collisions at RHIC

    International Nuclear Information System (INIS)

    Molnar, Levente; Barannikova, Olga; Wang, Fuqiang

    2006-01-01

    Statistical model fit to particle ratios in Au+Au collisions at RHIC suggests chemical freeze-out near phase transition boundary. Model interpretations of evolution from chemical to kinetic freeze-out vary. Results of the blast-wave fit to the STAR experimental data, where resonance contributions are not accounted for, suggest significant cooling and expansion between the freezeouts for central Au+Au collisions. Other models including resonances, argue for instant single freezeout with temperature close to the phase transition temperature. By combined thermal and blast-wave model parametrization including resonances, we systematically investigate the effect of resonance decays on the extracted kinetic freeze-out parameters. (authors)

  6. Effects of the hydromethanolic extract of Austroplenckia populnea (Celastraceae) on reproductive parameters of male rats.

    Science.gov (United States)

    Mazaro, Renata; Di Stasi, Luiz; De Grava Kempinas, Wilma

    2002-09-01

    Austroplenckia populnea (Reiss.) Lundell. was selected for this study because it has been shown that some plants from the Celastraceae family have antifertility effects. Twelve adult male rats were treated with hydromethanolic extract made from the leaves, 500 mg/kg/day, orally, for 70 days. Distilled water was administered to the control animals (n = 10). At the end of the experiment, and before killing the rats, their sexual behavior was evaluated. The number of intromissions, latencies to first mount and ejaculation, and first intromission after ejaculation were significantly reduced in the treated group, but the total number of ejaculations did not differ from the control group. The weight and histology of the reproductive organs, sperm production, spermatogenesis, prostate fructose content, cauda epidydimides duct diameter, and sperm morphology were not affected. Sperm concentration in cauda epidydimides was significantly decreased. The results showed that A. populnea has effects on male rat reproduction, affecting the sexual behavior and epididymal sperm concentration.

  7. Excavation-drier method of energy-peat extraction reduces long-term climatic impact

    Energy Technology Data Exchange (ETDEWEB)

    Silvan, N.; Silvan, K.; Laine, J. [Finnish Forest Research Inst., Parkano (Finland)], e-mail: niko.silvan@metla.fi; Vaisanen, S.; Soukka, R. [Lappeenranta Univ.of Techology (Finland)

    2012-11-01

    Climatic impacts of energy-peat extraction are of increasing concern due to EU emissions trading requirements. A new excavation-drier peat extraction method has been developed to reduce the climatic impact and increase the efficiency of peat extraction. To quantify and compare the soil GHG fluxes of the excavation drier and the traditional milling methods, as well as the areas from which the energy peat is planned to be extracted in the future (extraction reserve area types), soil CO{sub 2}, CH{sub 4} and N{sub 2}O fluxes were measured during 2006-2007 at three sites in Finland. Within each site, fluxes were measured from drained extraction reserve areas, extraction fields and stockpiles of both methods and additionally from the biomass driers of the excavation-drier method. The Life Cycle Assessment (LCA), described at a principal level in ISO Standards 14040:2006 and 14044:2006, was used to assess the long-term (100 years) climatic impact from peatland utilisation with respect to land use and energy production chains where utilisation of coal was replaced with peat. Coal was used as a reference since in many cases peat and coal can replace each other in same power plants. According to this study, the peat extraction method used was of lesser significance than the extraction reserve area type in regards to the climatic impact. However, the excavation-drier method seems to cause a slightly reduced climatic impact as compared with the prevailing milling method. (orig.)

  8. Methods for extracting dose response curves from radiation therapy data. I. A unified approach

    International Nuclear Information System (INIS)

    Herring, D.F.

    1980-01-01

    This paper discusses an approach to fitting models to radiation therapy data in order to extract dose response curves for tumor local control and normal tissue damage. The approach is based on the method of maximum likelihood and is illustrated by several examples. A general linear logistic equation which leads to the Ellis nominal standard dose (NSD) equation is discussed; the fit of this equation to experimental data for mouse foot skin reactions produced by fractionated irradiation is described. A logistic equation based on the concept that normal tissue reactions are associated with the surviving fraction of cells is also discussed, and the fit of this equation to the same set of mouse foot skin reaction data is also described. These two examples illustrate the importance of choosing a model based on underlying mechanisms when one seeks to attach biological significance to a model's parameters

  9. Parameter estimation of Monod model by the Least-Squares method for microalgae Botryococcus Braunii sp

    Science.gov (United States)

    See, J. J.; Jamaian, S. S.; Salleh, R. M.; Nor, M. E.; Aman, F.

    2018-04-01

    This research aims to estimate the parameters of Monod model of microalgae Botryococcus Braunii sp growth by the Least-Squares method. Monod equation is a non-linear equation which can be transformed into a linear equation form and it is solved by implementing the Least-Squares linear regression method. Meanwhile, Gauss-Newton method is an alternative method to solve the non-linear Least-Squares problem with the aim to obtain the parameters value of Monod model by minimizing the sum of square error ( SSE). As the result, the parameters of the Monod model for microalgae Botryococcus Braunii sp can be estimated by the Least-Squares method. However, the estimated parameters value obtained by the non-linear Least-Squares method are more accurate compared to the linear Least-Squares method since the SSE of the non-linear Least-Squares method is less than the linear Least-Squares method.

  10. Current lipid extraction methods are significantly enhanced adding a water treatment step in Chlorella protothecoides.

    Science.gov (United States)

    Ren, Xiaojie; Zhao, Xinhe; Turcotte, François; Deschênes, Jean-Sébastien; Tremblay, Réjean; Jolicoeur, Mario

    2017-02-11

    Microalgae have the potential to rapidly accumulate lipids of high interest for the food, cosmetics, pharmaceutical and energy (e.g. biodiesel) industries. However, current lipid extraction methods show efficiency limitation and until now, extraction protocols have not been fully optimized for specific lipid compounds. The present study thus presents a novel lipid extraction method, consisting in the addition of a water treatment of biomass between the two-stage solvent extraction steps of current extraction methods. The resulting modified method not only enhances lipid extraction efficiency, but also yields a higher triacylglycerols (TAG) ratio, which is highly desirable for biodiesel production. Modification of four existing methods using acetone, chloroform/methanol (Chl/Met), chloroform/methanol/H 2 O (Chl/Met/H 2 O) and dichloromethane/methanol (Dic/Met) showed respective lipid extraction yield enhancement of 72.3, 35.8, 60.3 and 60.9%. The modified acetone method resulted in the highest extraction yield, with 68.9 ± 0.2% DW total lipids. Extraction of TAG was particularly improved with the water treatment, especially for the Chl/Met/H 2 O and Dic/Met methods. The acetone method with the water treatment led to the highest extraction level of TAG with 73.7 ± 7.3 µg/mg DW, which is 130.8 ± 10.6% higher than the maximum value obtained for the four classical methods (31.9 ± 4.6 µg/mg DW). Interestingly, the water treatment preferentially improved the extraction of intracellular fractions, i.e. TAG, sterols, and free fatty acids, compared to the lipid fractions of the cell membranes, which are constituted of phospholipids (PL), acetone mobile polar lipids and hydrocarbons. Finally, from the 32 fatty acids analyzed for both neutral lipids (NL) and polar lipids (PL) fractions, it is clear that the water treatment greatly improves NL-to-PL ratio for the four standard methods assessed. Water treatment of biomass after the first solvent extraction step

  11. Measures of Ruleset Quality for General Rules Extraction Methods

    Czech Academy of Sciences Publication Activity Database

    Holeňa, Martin

    2009-01-01

    Roč. 50, č. 6 (2009), s. 867-879 ISSN 0888-613X R&D Projects: GA ČR GA201/08/0802 Institutional research plan: CEZ:AV0Z10300504 Keywords : rules extraction from data * quality measures * ruleset measures * ROC curves * observational logic * fuzzy logic Subject RIV: IN - Informatics, Computer Science Impact factor: 2.090, year: 2009

  12. GA Based Optimal Feature Extraction Method for Functional Data Classification

    OpenAIRE

    Jun Wan; Zehua Chen; Yingwu Chen; Zhidong Bai

    2010-01-01

    Classification is an interesting problem in functional data analysis (FDA), because many science and application problems end up with classification problems, such as recognition, prediction, control, decision making, management, etc. As the high dimension and high correlation in functional data (FD), it is a key problem to extract features from FD whereas keeping its global characters, which relates to the classification efficiency and precision to heavens. In this paper...

  13. Accelerated solvent extraction method with one-step clean-up for hydrocarbons in soil

    International Nuclear Information System (INIS)

    Nurul Huda Mamat Ghani; Norashikin Sain; Rozita Osman; Zuraidah Abdullah Munir

    2007-01-01

    The application of accelerated solvent extraction (ASE) using hexane combined with neutral silica gel and sulfuric acid/ silica gel (SA/ SG) to remove impurities prior to analysis by gas chromatograph with flame ionization detector (GC-FID) was studied. The efficiency of extraction was evaluated based on the three hydrocarbons; dodecane, tetradecane and pentadecane spiked to soil sample. The effect of ASE operating conditions (extraction temperature, extraction pressure, static time) was evaluated and the optimized condition obtained from the study was extraction temperature of 160 degree Celsius, extraction pressure of 2000 psi with 5 minutes static extraction time. The developed ASE with one-step clean-up method was applied in the extraction of hydrocarbons from spiked soil and the amount extracted was comparable to ASE extraction without clean-up step with the advantage of obtaining cleaner extract with reduced interferences. Therefore in the developed method, extraction and clean-up for hydrocarbons in soil can be achieved rapidly and efficiently with reduced solvent usage. (author)

  14. A motion algorithm to extract physical and motion parameters of mobile targets from cone-beam computed tomographic images.

    Science.gov (United States)

    Alsbou, Nesreen; Ahmad, Salahuddin; Ali, Imad

    2016-05-17

    A motion algorithm has been developed to extract length, CT number level and motion amplitude of a mobile target from cone-beam CT (CBCT) images. The algorithm uses three measurable parameters: Apparent length and blurred CT number distribution of a mobile target obtained from CBCT images to determine length, CT-number value of the stationary target, and motion amplitude. The predictions of this algorithm are tested with mobile targets having different well-known sizes that are made from tissue-equivalent gel which is inserted into a thorax phantom. The phantom moves sinusoidally in one-direction to simulate respiratory motion using eight amplitudes ranging 0-20 mm. Using this motion algorithm, three unknown parameters are extracted that include: Length of the target, CT number level, speed or motion amplitude for the mobile targets from CBCT images. The motion algorithm solves for the three unknown parameters using measured length, CT number level and gradient for a well-defined mobile target obtained from CBCT images. The motion model agrees with the measured lengths which are dependent on the target length and motion amplitude. The gradient of the CT number distribution of the mobile target is dependent on the stationary CT number level, the target length and motion amplitude. Motion frequency and phase do not affect the elongation and CT number distribution of the mobile target and could not be determined. A motion algorithm has been developed to extract three parameters that include length, CT number level and motion amplitude or speed of mobile targets directly from reconstructed CBCT images without prior knowledge of the stationary target parameters. This algorithm provides alternative to 4D-CBCT without requirement of motion tracking and sorting of the images into different breathing phases. The motion model developed here works well for tumors that have simple shapes, high contrast relative to surrounding tissues and move nearly in regular motion pattern

  15. Calculation of parameter failure probability of thermodynamic system by response surface and importance sampling method

    International Nuclear Information System (INIS)

    Shang Yanlong; Cai Qi; Chen Lisheng; Zhang Yangwei

    2012-01-01

    In this paper, the combined method of response surface and importance sampling was applied for calculation of parameter failure probability of the thermodynamic system. The mathematics model was present for the parameter failure of physics process in the thermodynamic system, by which the combination arithmetic model of response surface and importance sampling was established, then the performance degradation model of the components and the simulation process of parameter failure in the physics process of thermodynamic system were also present. The parameter failure probability of the purification water system in nuclear reactor was obtained by the combination method. The results show that the combination method is an effective method for the calculation of the parameter failure probability of the thermodynamic system with high dimensionality and non-linear characteristics, because of the satisfactory precision with less computing time than the direct sampling method and the drawbacks of response surface method. (authors)

  16. Research on filter’s parameter selection based on PROMETHEE method

    Science.gov (United States)

    Zhu, Hui-min; Wang, Hang-yu; Sun, Shi-yan

    2018-03-01

    The selection of filter’s parameters in target recognition was studied in this paper. The PROMETHEE method was applied to the optimization problem of Gabor filter parameters decision, the correspondence model of the elemental relation between two methods was established. The author took the identification of military target as an example, problem about the filter’s parameter decision was simulated and calculated by PROMETHEE. The result showed that using PROMETHEE method for the selection of filter’s parameters was more scientific. The human disturbance caused by the experts method and empirical method could be avoided by this way. The method can provide reference for the parameter configuration scheme decision of the filter.

  17. Effect of bioactive compounds extracted from euphorbious plants on hematological and biochemical parameters of Channa punctatus

    Directory of Open Access Journals (Sweden)

    Jaya Shahi

    2011-10-01

    Full Text Available Channa punctatus was exposed to four different concentrations of Rutin, Taraxerol and Apigenin. Changes in some hematological parameters of Channa punctatus were assessed to determine the influence of these compounds on test fish. Fish were exposed to sublethal concentrations (80% of LC50 of 24h of these compounds for one week. Control fish were also administered for one week. Thereafter, blood samples were obtained from the control and experimental fish. Blood was assayed for selected hematological parameters (hematocrit, hemoglobin, red blood cell count, white blood cell count total plasma protein and plasma glucose concentration. The derived hematological indices of mean corpuscular hemoglobin concentration (MCHC, mean corpuscular hemoglobin (MCH and mean corpuscular volume (MCV were calculated. Sublethal concentrations of these compounds caused a dose dependent decrease in hemoglobin values coupled with a decrease in hematocrit values and red blood cell counts are an obvious indication of anemia. The total white blood cell counts and the differential white blood cell counts were decreased except for the lymphocytes, where there was a slight increase. Plasma protein and glucose were also lower in exposed fish when compared with control. The hematological indices MCH, MCHC, MCV were also lowered. The result from this study reveals high mortality rate and deleterious consequences on the health of fish subjected to acute exposure of Rutin, Taraxerol and Apigenin and therefore, should not be used directly in aquaculture without having the proper knowledge.

  18. The influence of extraction methods on composition and antioxidant properties of rice bran oil

    Directory of Open Access Journals (Sweden)

    Noppawat Pengkumsri

    2015-09-01

    Full Text Available AbstractThe current study was employed to assess the influence of the different extraction methods on total tocols, γ-oryzanol content, and antioxidant properties of Chiang Mai Black rice, Mali Red rice, and Suphanburi-1 Brown rice bran oil. Rice bran oil (RBO was extracted by Hexane, Hot pressed, Cold pressed, and Supercritical Fluid Extraction (SFe methods. High yield of RBO was extracted by hexane and SFe methods. Total and subgroups of tocols, and γ-oryzanol content were determined by HPLC. The hexane extracted sample accounts for high content of γ-oryzanol and tocols. Besides, all of RBO extracts contain a significantly high amount of γ-tocotrienol. In vitro antioxidant assay results indicated that superior quality of oil was recovered by hexane extraction. The temperature in the extraction process also affects the value of the oil. Superior quality of oil was recovered by hexane extraction, in terms of phytochemical contents and antioxidant properties compared to other tested extraction methods. Further, thorough study of factors compromising the quality and quantity of RBO recovery is required for the development of enhanced functional foods and other related products.

  19. Methods for producing extracted and digested products from pretreated lignocellulosic biomass

    Science.gov (United States)

    Chundawat, Shishir; Sousa, Leonardo Da Costa; Cheh, Albert M.; Balan; , Venkatesh; Dale, Bruce

    2017-05-16

    Methods for producing extracted and digested products from pretreated lignocellulosic biomass are provided. The methods include converting native cellulose I.sub..beta. to cellulose III.sub.I by pretreating the lignocellulosic biomass with liquid ammonia under certain conditions, and performing extracting or digesting steps on the pretreated/converted lignocellulosic biomass.

  20. Efficient method for extracting DNA of parasites causing bovine babesiosis from tick vectors

    Science.gov (United States)

    The southern cattle tick, Rhipicephalus (Boophilus) microplus, is an economically important pest costing animal agriculture billions of dollars worldwide. This research focuses on a comparison of three different tick DNA extraction methods: phenol-chloroform extraction (method 1), a modified version...

  1. Rate-equation modelling and ensemble approach to extraction of parameters for viral infection-induced cell apoptosis and necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Domanskyi, Sergii; Schilling, Joshua E.; Privman, Vladimir, E-mail: privman@clarkson.edu [Department of Physics, Clarkson University, Potsdam, New York 13676 (United States); Gorshkov, Vyacheslav [National Technical University of Ukraine — KPI, Kiev 03056 (Ukraine); Libert, Sergiy, E-mail: libert@cornell.edu [Department of Biomedical Sciences, Cornell University, Ithaca, New York 14853 (United States)

    2016-09-07

    We develop a theoretical approach that uses physiochemical kinetics modelling to describe cell population dynamics upon progression of viral infection in cell culture, which results in cell apoptosis (programmed cell death) and necrosis (direct cell death). Several model parameters necessary for computer simulation were determined by reviewing and analyzing available published experimental data. By comparing experimental data to computer modelling results, we identify the parameters that are the most sensitive to the measured system properties and allow for the best data fitting. Our model allows extraction of parameters from experimental data and also has predictive power. Using the model we describe interesting time-dependent quantities that were not directly measured in the experiment and identify correlations among the fitted parameter values. Numerical simulation of viral infection progression is done by a rate-equation approach resulting in a system of “stiff” equations, which are solved by using a novel variant of the stochastic ensemble modelling approach. The latter was originally developed for coupled chemical reactions.

  2. Effects of Saw Palmetto Extract on Urodynamic Parameters, Bladder Muscarinic and Purinergic Receptors and Urinary Cytokines in Rats with Cyclophosphamide-Induced Cystitis.

    Science.gov (United States)

    Nasrin, Sweety; Masuda, Eiji; Kugaya, Haruna; Osano, Ayaka; Ito, Yoshihiko; Yamada, Shizuo

    2014-01-01

    To clarify the effect of saw palmetto extract (SPE), a phytotherapeutic agent, on urodynamic parameters, bladder muscarinic and purinergic receptors, and urinary cytokines in rats with cystitis induced by cyclophosphamide (CYP). Saw palmetto extract (60 mg/kg per day) was administered orally twice a day for 7 days to rats. The urodynamic parameters in CYP (150 mg/kg i.p.)-treated rats were monitored by a cystometric method under anesthesia. The muscarinic and purinergic receptors in the bladder and submaxillary gland were measured by radioreceptor assays using [N-methyl-(3) H] scopolamine chloride([(3) H]NMS) and αβ-methylene-ATP [2,8-(3) H] tetrasodium salt ([(3) H]αβ-MeATP), respectively. Urinary cytokines (interleukin-1β [IL-1β], IL-6 and L-17) were measured with enzyme linked immunosorbent assay kits. Micturition interval and micturition volume were significantly decreased and the frequency of micturition and basal pressure were significantly increased in the CYP-treated rats compared with sham-operated rats. Orally administered SPE significantly increased the micturition interval and micturition volume and decreased the frequency of micturition and basal pressure. The maximal number of sites (Bmax ) for the specific binding of [(3) H]NMS and [(3) H]αβ-MeATP was significantly decreased in the bladder. The decrease in receptors was attenuated by repeated treatment with SPE. An elevation in urinary cytokine (IL-1β and IL-17) levels were seen, and this increase was effectively suppressed by SPE treatment. Saw palmetto extract attenuates the alteration of urodynamic parameters, pharmacologically relevant receptors, and urinary cytokines in CYP-treated rats. Therefore, SPE may be a potential therapeutic agent for improving the clinical symptoms of cystitis. © 2013 Wiley Publishing Asia Pty Ltd.

  3. Extraction of Plant Physiological Status from Hyperspectral Signatures Using Machine Learning Methods

    Directory of Open Access Journals (Sweden)

    Daniel Doktor

    2014-12-01

    Full Text Available The machine learning method, random forest (RF, is applied in order to derive biophysical and structural vegetation parameters from hyperspectral signatures. Hyperspectral data are, among other things, characterized by their high dimensionality and autocorrelation. Common multivariate regression approaches, which usually include only a limited number of spectral indices as predictors, do not make full use of the available information. In contrast, machine learning methods, such as RF, are supposed to be better suited to extract information on vegetation status. First, vegetation parameters are extracted from hyperspectral signatures simulated with the radiative transfer model, PROSAIL. Second, the transferability of these results with respect to laboratory and field measurements is investigated. In situ observations of plant physiological parameters and corresponding spectra are gathered in the laboratory for summer barley (Hordeum vulgare. Field in situ measurements focus on winter crops over several growing seasons. Chlorophyll content, Leaf Area Index and phenological growth stages are derived from simulated and measured spectra. RF performs very robustly and with a very high accuracy on PROSAIL simulated data. Furthermore, it is almost unaffected by introduced noise and bias in the data. When applied to laboratory data, the prediction accuracy is still good (C\\(_{ab}\\: \\(R^2\\ = 0.94/ LAI: \\(R^2\\ = 0.80/BBCH (Growth stages of mono-and dicotyledonous plants : \\(R^2\\ = 0.91, but not as high as for simulated spectra. Transferability to field measurements is given with prediction levels as high as for laboratory data (C\\(_{ab}\\: \\(R^2\\ = 0.89/LAI: \\(R^2\\ = 0.89/BBCH: \\(R^2\\ = \\(\\sim\\0.8. Wavelengths for deriving plant physiological status based on simulated and measured hyperspectral signatures are mostly selected from appropriate spectral regions (both field and laboratory: 700–800 nm regressing on C\\(_{ab}\\ and 800–1300

  4. Extracting quantitative structural parameters for disordered polymers from neutron scattering data

    International Nuclear Information System (INIS)

    Rosi-Schwartz, B.; Mitchell, G.R.

    1995-01-01

    The organization of non-crystalline polymeric materials at a local level, namely on a spatial scale between a few and 100 A, is still unclear in many respects. The determination of the local structure in terms of the configuration and conformation of the polymer chain and of the packing characteristics of the chain in the bulk material represents a challenging problem. Data from wide-angle diffraction experiments are very difficult to interpret due to the very large amount of information that they carry, that is the large number of correlations present in the diffraction patterns.We describe new approaches that permit a detailed analysis of the complex neutron diffraction patterns characterizing polymer melts and glasses. The coupling of different computer modelling strategies with neutron scattering data over a wide Q range allows the extraction of detailed quantitative information on the structural arrangements of the materials of interest. Proceeding from modelling routes as diverse as force field calculations, single-chain modelling and reverse Monte Carlo, we show the successes and pitfalls of each approach in describing model systems, which illustrate the need to attack the data analysis problem simultaneously from several fronts. ((orig.))

  5. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin.

    Science.gov (United States)

    Thoisen, Christina; Hansen, Benni Winding; Nielsen, Søren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. The cryptophyte cells on the filters were disrupted at -80 °C and added phosphate buffer for extraction at 4 °C followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes.•Minimal usage of equipment and chemicals, and low labor costs.•Applicable for industrial and biological purposes.

  6. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin

    DEFF Research Database (Denmark)

    Thoisen, Christina Vinum; Hansen, Benni Winding; Nielsen, Søren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive...... freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. Filters with the cryptophyte were frozen (−80 °C) and added phosphate buffer for extraction at 4 °C...... followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes. •Minimal usage of equipment and chemicals, and low labor costs. •Applicable for industrial and biological purposes....

  7. Implant-buccal plate distance as diagnostic parameter: a prospective cohort study on implant placement in fresh extraction sockets.

    Science.gov (United States)

    Capelli, Matteo; Testori, Tiziano; Galli, Fabio; Zuffetti, Francesco; Motroni, Alessandro; Weinstein, Roberto; Del Fabbro, Massimo

    2013-12-01

    The aim of this study is to investigate contour changes around immediate implants in fresh extraction sockets when different grafting procedures are performed, based on the distance between the external implant collar and the bony surface on the buccal plate (I-BP). A secondary aim is to assess the esthetic outcome via the implant esthetic score (IAS). This prospective cohort study was performed in three centers. Suitable patients to undergo implant placement in fresh extraction sockets were selected. Periodontal biotype, horizontal and vertical peri-implant bone defects, and dehiscences were assessed. Depending on I-BP, two types of grafting procedures were performed. In group A (I-BP sockets. No implant failed during the observation period. The mean follow-up was 25 months (range: 12 to 37 months). After 1 year of loading, group A showed a slight decrease in mean buccal volume, whereas group B had an increase in volume (P = 0.02). IAS was higher for group B than group A. When implants are placed immediately after tooth extraction, I-BP may represent a useful diagnostic parameter in choosing the most appropriate grafting procedure (IG versus IEG). In clinical cases in which the distance between implant surface and the buccal plate is <4 mm, the combination of internal and external grafting (IEG) is recommended to maintain the volume and the contour of the ridge and achieve a successful esthetic outcome.

  8. Effect of dietary supplementation with propolis and Aloe barbadensis extracts on hematological parameters and parasitism in Nile tilapia

    Directory of Open Access Journals (Sweden)

    Geovana Dotta

    Full Text Available This study evaluated the influence of diet supplementation with propolis and Aloe barbadensis on hematological parameters and parasitism in tilapia. One hundred and eighty fish were distributed among 12 water tanks forming four treatments: fish supplemented with a 1:1 mixture of 0%, 0.5%, 1% and 2% propolis and aloe extracts. After the fish had been fed on the experimental diets for 15 and 21 days, blood samples were taken and parasites collected. The monogeneans Cichlidogyrus sclerosus, C. halli, C. thurstonae and Scutogyrus longicornis were identified in the gills. Between the sampling times, there were increases in the numbers of erythrocytes, leukocytes, thrombocytes and lymphocytes, as observed after 21 days, possibly due to the stress level over the course of the assay and/or accumulation of substances in the organism. Supplementation with the mixture of propolis and aloe for 15 days showed the highest efficacy against the parasites. This was possibly due to the association between the two compounds. The results demonstrated that supplementation with mixtures of extracts did not produce hematological alterations and also favored a significant reduction in the number of gill parasites. The best results were achieved after 15 days of feeding with a diet with 0.5% and 1% supplementation with the extract mixture, which increased efficiency by 83 and 85% respectively

  9. The influence of the Tribulus terrestris extract on the parameters of the functional preparedness and athletes' organism homeostasis.

    Science.gov (United States)

    Milasius, K; Dadeliene, R; Skernevicius, Ju

    2009-01-01

    The influence of the Tribulus terrestris extract on the parameters of the functional preparadness and athletes' organism homeostase was investigated. It was established the positive impact of dietary supplement "Tribulus" (Optimum Nutrition, U.S.A.) using per 1 capsule 3 times a day during 20 days on athletes' physical power in various energy producing zones: anaerobic alactic muscular power and anaerobic alactic glycolytic power statistically reliable increased. Tribulus terrestris extract, after 20 days of consuming it, did not have essential effect on erythrocytes, haemoglobin and thrombocytes indices. During the experimental period statistically importantly increased percentage of granulocytes and decreased percentage of leucocytes show negative impact of this food supplement on changes of leucocytes formula in athletes' blood. Creatinkinase concentration in athletes' blood statistically importantly has increased and creatinine amount has had a tendency to decline during 20 days period of consuming Tribulus terrestris extract. The declining tendency of urea, cholesterol and bilirubin concentrations has appeared. The concentration of blood testosterone increased statistically reliable during the first half (10 days) of the experiment; it did not grow during the next 10 days while consuming Tribulus still.

  10. Effects of Common Fig (Ficus carica Leaf Extracts on Sperm Parameters and Testis of Mice Intoxicated with Formaldehyde

    Directory of Open Access Journals (Sweden)

    Majid Naghdi

    2016-01-01

    Full Text Available Formaldehyde (FA is the leading cause of cellular injury and oxidative damage in testis that is one of the main infertility causes. There has been an increasing evidence of herbal remedies use in male infertility treatment. This assay examines the role of Ficus carica (Fc leaf extracts in sperm parameters and testis of mice intoxicated with FA. Twenty-five adult male mice were randomly divided into control; sham; FA-treated (10 mg/kg twice per day; Fc-treated (200 mg/kg; and FA + Fc-treated groups. Cauda epididymal spermatozoa were analyzed for viability, count, and motility. Testes were weighed and gonadosomatic index (GSI was calculated. Also, histoarchitecture of seminiferous tubules was assessed in the Haematoxylin and Eosin stained paraffin sections. The findings showed that FA significantly decreased GSI and increased percentage of immotile sperm compared with control group. Disorganized and vacuolated seminiferous epithelium, spermatogenic arrest, and lumen filled with immature germ cells were also observed in the testes. However, Fc leaf extracts improved sperm count, nonprogressive motility of spermatozoa, and GSI in FA-treated testes. Moreover, seminiferous tubule with spermatogenic arrest was rarely seen, indicating that Fc has the positive effects on testis and epididymal sperm parameters exposed with FA.

  11. Extracting lunar dust parameters from image charge signals produced by the Lunar Dust Experiment

    Science.gov (United States)

    Stanley, J.; Kempf, S.; Horanyi, M.; Szalay, J.

    2015-12-01

    The Lunar Dust Experiment (LDEX) onboard the Lunar Atmosphere and Dust Environment Explorer (LADEE) is an impact ionization dust detector used to characterize the lunar dust exosphere generated by the impacts of large interplanetary particles and meteor streams (Horanyi et al., 2015). In addition to the mass and speed of these lofted particles, LDEX is sensitive to their charge. The resulting signatures of impact events therefore provide valuable information about not only the ambient plasma environment, but also the speed vectors of these dust grains. Here, impact events produced from LDEX's calibration at the Dust Accelerator Laboratory are analyzed using an image charge model derived from the electrostatic simulation program, Coulomb. We show that parameters such as dust grain speed, size, charge, and position of entry into LDEX can be recovered and applied to data collected during LADEE's seven-month mission.

  12. Comparison of two methods of surface profile extraction from multiple ultrasonic range measurements

    NARCIS (Netherlands)

    Barshan, B; Baskent, D

    Two novel methods for surface profile extraction based on multiple ultrasonic range measurements are described and compared. One of the methods employs morphological processing techniques, whereas the other employs a spatial voting scheme followed by simple thresholding. Morphological processing

  13. The BUME method: a new rapid and simple chloroform-free method for total lipid extraction of animal tissue.

    Science.gov (United States)

    Löfgren, Lars; Forsberg, Gun-Britt; Ståhlman, Marcus

    2016-06-10

    In this study we present a simple and rapid method for tissue lipid extraction. Snap-frozen tissue (15-150 mg) is collected in 2 ml homogenization tubes. 500 μl BUME mixture (butanol:methanol [3:1]) is added and automated homogenization of up to 24 frozen samples at a time in less than 60 seconds is performed, followed by a 5-minute single-phase extraction. After the addition of 500 μl heptane:ethyl acetate (3:1) and 500 μl 1% acetic acid a 5-minute two-phase extraction is performed. Lipids are recovered from the upper phase by automated liquid handling using a standard 96-tip robot. A second two-phase extraction is performed using 500 μl heptane:ethyl acetate (3:1). Validation of the method showed that the extraction recoveries for the investigated lipids, which included sterols, glycerolipids, glycerophospholipids and sphingolipids were similar or better than for the Folch method. We also applied the method for lipid extraction of liver and heart and compared the lipid species profiles with profiles generated after Folch and MTBE extraction. We conclude that the BUME method is superior to the Folch method in terms of simplicity, through-put, automation, solvent consumption, economy, health and environment yet delivering lipid recoveries fully comparable to or better than the Folch method.

  14. The BUME method: a new rapid and simple chloroform-free method for total lipid extraction of animal tissue

    Science.gov (United States)

    Löfgren, Lars; Forsberg, Gun-Britt; Ståhlman, Marcus

    2016-06-01

    In this study we present a simple and rapid method for tissue lipid extraction. Snap-frozen tissue (15-150 mg) is collected in 2 ml homogenization tubes. 500 μl BUME mixture (butanol:methanol [3:1]) is added and automated homogenization of up to 24 frozen samples at a time in less than 60 seconds is performed, followed by a 5-minute single-phase extraction. After the addition of 500 μl heptane:ethyl acetate (3:1) and 500 μl 1% acetic acid a 5-minute two-phase extraction is performed. Lipids are recovered from the upper phase by automated liquid handling using a standard 96-tip robot. A second two-phase extraction is performed using 500 μl heptane:ethyl acetate (3:1). Validation of the method showed that the extraction recoveries for the investigated lipids, which included sterols, glycerolipids, glycerophospholipids and sphingolipids were similar or better than for the Folch method. We also applied the method for lipid extraction of liver and heart and compared the lipid species profiles with profiles generated after Folch and MTBE extraction. We conclude that the BUME method is superior to the Folch method in terms of simplicity, through-put, automation, solvent consumption, economy, health and environment yet delivering lipid recoveries fully comparable to or better than the Folch method.

  15. Investigation of Di-ethylhexyl Phthalate Migration by Applying Magnetic Solid Phase Extraction Method Followed by GC-FID Determination

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-10-01

    Full Text Available Background and Objectives: The addition of plasticizers (mainly phthalates and adipates makes plastic flexible and popular for packaging, storing and preserving food, water, and so on. The most widely used plasticizer in food contact applications is di-ethylhexyl phthalate (DEHP though being suspected to have carcinogenic and estrogenic properties. The aim of this study is application of magnetic solid phase extraction as new absorbent for determination of DEHP in water samples by gas chromatography (GC. Materials and Methods: Important factors in extraction, separation and determination processes were optimized using the one-variable-at-a-time method. For optimization, all tests were performed two times. Figures of merit of the proposed method were evaluated. The amount of DEHP in some water samples was determined using the proposed method. Results: The results showed that the obtained chromatogram of extract was free of significant interference. The preservatives’ recoveries ranged from 91.6% to 102.2%. Limit of detection and limit of quantitation were 0.1 mg kg-1 and 0.3 µg L-1, respectively. Concentration of DEHP in the studied samples was in the range of N.D-2.3 µg L-1. Conclusions: The acceptable performance and reliability of the proposed method were demonstrated. Temperature and time were fount as the most effective parameters in migration of DEHP. Keywords: Di-ethylhexyl phthalate, Magnetic solid phase extraction, Migration, Gas chromatography

  16. Determination of the kinetic parameters of BeO using isothermal decay method

    International Nuclear Information System (INIS)

    Nieto, Juan Azorin; Vega, Claudia Azorin; Montalvo, Teodoro Rivera; Cabrera, Eugenio Torijano

    2016-01-01

    Most of the existing methods for obtaining the frequency factors make use of the trap depth (activation energy) making some assumptions about the order of the kinetics. This causes inconsistencies in the reported values of trapping parameters due that the values of the activation energy obtained by different methods differ appreciably among them. Then, it is necessary to use a method independent of the trap depth making use of the isothermal luminescence decay (ILD) method. The trapping parameters associated with the prominent glow peak of BeO (280 °C) are reported using ILD method. As a check, the trap parameters are also calculated by glow curve shape (Chen's) method after isolating the prominent glow peak by thermal cleaning technique. Our results show a very good agreement between the trapping parameters calculated by the two methods. ILD method was used for determining the trapping parameters of BeO. Results obtained applying this method are in good agreement with those obtained using other methods, except in the value of the frequency factor. - Highlights: • Kinetic parameters of BeO were determined. • Isothermal decay method was used. • Frecuency factor not agree with those obtained by other methods.

  17. Comparison of different methods for extraction from Tetraclinis articulata: yield, chemical composition and antioxidant activity.

    Science.gov (United States)

    Herzi, Nejia; Bouajila, Jalloul; Camy, Séverine; Romdhane, Mehrez; Condoret, Jean-Stéphane

    2013-12-15

    In the present study, three techniques of extraction: hydrodistillation (HD), solvent extraction (conventional 'Soxhlet' technique) and an innovative technique, i.e., the supercritical fluid extraction (SFE), were applied to ground Tetraclinis articulata leaves and compared for extraction duration, extraction yield, and chemical composition of the extracts as well as their antioxidant activities. The extracts were analyzed by GC-FID and GC-MS. The antioxidant activity was measured using two methods: ABTS(•+) and DPPH(•). The yield obtained using HD, SFE, hexane and ethanol Soxhlet extractions were found to be 0.6, 1.6, 40.4 and 21.2-27.4 g/kg respectively. An original result of this study is that the best antioxidant activity was obtained with an SFE extract (41 mg/L). The SFE method offers some noteworthy advantages over traditional alternatives, such as shorter extraction times, low environmental impact, and a clean, non-thermally-degraded final product. Also, a good correlation between the phenolic contents and the antioxidant activity was observed with extracts obtained by SFE at 9 MPa. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Evaluation of Extraction and Degradation Methods to Obtain Chickpeasaponin B1 from Chickpea (Cicer arietinum L.

    Directory of Open Access Journals (Sweden)

    Kun Cheng

    2017-02-01

    Full Text Available The objective of this research is to implement extraction and degradation methods for the obtainment of 3-O-[α-l-rhamnopyranosyl-(1→2-β-d-galactopyranosyl] soyasapogenol B (chickpeasaponin B1 from chickpea. The effects of microwave-assisted extraction (MAE processing parameters—such as ethanol concentration, solvent/solid ratio, extraction temperature, microwave irradiation power, and irradiation time—were evaluated. Using 1g of material with 8 mL of 70% aqueous ethanol and an extraction time of 10 min at 70 °C under irradiation power 400W provided optimal extraction conditions. Compared with the conventional extraction techniques, including heat reflux extraction (HRE, Soxhlet extraction (SE, and ultrasonic extraction (UE, MAE produced higher extraction efficiency under a lower extraction time. DDMP (2,3-dihydro-2,5-dihydroxy-6-methyl-4H-pyran-4-one saponin can be degraded to structurally stable saponin B by the loss of its DDMP group. The influence of pH and the concentration of potassium hydroxide on transformation efficiency of the target compound was investigated. A solution of 0.25 M potassium hydroxide in 75% aqueous ethanol was suitable for converting the corresponding DDMP saponins of chickpeasaponin B1. The implementation by the combining MAE technique and alkaline hydrolysis method for preparing chickpeasaponin B1 provides a convenient technology for future applications.

  19. EXTRACT

    DEFF Research Database (Denmark)

    Pafilis, Evangelos; Buttigieg, Pier Luigi; Ferrell, Barbra

    2016-01-01

    The microbial and molecular ecology research communities have made substantial progress on developing standards for annotating samples with environment metadata. However, sample manual annotation is a highly labor intensive process and requires familiarity with the terminologies used. We have the...... and text-mining-assisted curation revealed that EXTRACT speeds up annotation by 15-25% and helps curators to detect terms that would otherwise have been missed.Database URL: https://extract.hcmr.gr/......., organism, tissue and disease terms. The evaluators in the BioCreative V Interactive Annotation Task found the system to be intuitive, useful, well documented and sufficiently accurate to be helpful in spotting relevant text passages and extracting organism and environment terms. Comparison of fully manual...

  20. Parameter Selection Method for Support Vector Regression Based on Adaptive Fusion of the Mixed Kernel Function

    Directory of Open Access Journals (Sweden)

    Hailun Wang

    2017-01-01

    Full Text Available Support vector regression algorithm is widely used in fault diagnosis of rolling bearing. A new model parameter selection method for support vector regression based on adaptive fusion of the mixed kernel function is proposed in this paper. We choose the mixed kernel function as the kernel function of support vector regression. The mixed kernel function of the fusion coefficients, kernel function parameters, and regression parameters are combined together as the parameters of the state vector. Thus, the model selection problem is transformed into a nonlinear system state estimation problem. We use a 5th-degree cubature Kalman filter to estimate the parameters. In this way, we realize the adaptive selection of mixed kernel function weighted coefficients and the kernel parameters, the regression parameters. Compared with a single kernel function, unscented Kalman filter (UKF support vector regression algorithms, and genetic algorithms, the decision regression function obtained by the proposed method has better generalization ability and higher prediction accuracy.