WorldWideScience

Sample records for oxygen deficiency monitors

  1. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-01-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  2. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-05-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  3. Alarm points for fixed oxygen monitors

    International Nuclear Information System (INIS)

    Miller, G.C.

    1987-05-01

    Oxygen concentration monitors were installed in a vault where numerous pipes carried inert cryogens and gases to the Mirror Fusion Test Facility (MFTF-B) experimental vessel at Lawrence Livermore National Laboratory (LLNL). The problems associated with oxygen-monitoring systems and the reasons why such monitors were installed were reviewed. As a result of this review, the MFTF-B monitors were set to sound an evacuation alarm when the oxygen concentration fell below 18%. We chose the 18% alarm criterion to minimize false alarms and to allow time for personnel to escape in an oxygen-deficient environment

  4. ODH, oxygen deficiency hazard cryogenic analysis

    International Nuclear Information System (INIS)

    Augustynowicz, S.D.

    1994-01-01

    An oxygen deficiency exists when the concentration of oxygen, by volume, drops to a level at which atmosphere supplying respiratory protection must be provided. Since liquid cryogens can expand by factors of 700 (LN 2 ) to 850 (LH e ), the uncontrolled release into an enclosed space can easily cause an oxygen-deficient condition. An oxygen deficiency hazard (ODH) fatality rate per hour (OE) is defined as: OE = Σ N i P i F i , where N i = number of components, P i = probability of failure or operator error, and F i = fatality factor. ODHs range from open-quotes unclassifiedclose quotes (OE -9 1/h) to class 4, which is the most hazardous (OE>10 -1 1/h). For Superconducting Super Collider Laboratory (SSCL) buildings where cryogenic systems exist, failure rate, fatality factor, reduced oxygen ratio, and fresh air circulation are examined

  5. Oxygen deficiency impacts on burying habitats for lesser sandeel, Ammodytes tobianus, in the inner Danish waters

    DEFF Research Database (Denmark)

    Behrens, Jane; Ærtebjerg, Gunni; Petersen, Jens Kjerulf

    2009-01-01

    Starting in 1980s, the inner Danish waters have yearly been exposed to seasonal oxygen deficiency (hypoxia). Through spatial–temporal interpolation of monitoring data (1998–2005), we investigated oxygen deficiency impacts on suitable burying habitats for lesser sandeel (Ammodytes tobianus...

  6. Investigation of ferromagnetism in oxygen deficient hafnium oxide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Hildebrandt, Erwin; Kurian, Jose; Krockenberger, Yoshiharu; Alff, Lambert [Institut fuer Materialwissenschaft, TU Darmstadt (Germany); Suter, Andreas [PSI, Villingen (Switzerland); Wilhelm, Fabrice; Rogalev, Andrei [ESRF, Grenoble (France)

    2008-07-01

    Oxygen deficient thin films of hafnium oxide were grown on single crystal r-cut and c-cut sapphire by reactive molecular beam epitaxy. RF-activated oxygen was used for the in situ oxidation of hafnium oxide thin films. Oxidation conditions were varied substantially in order to create oxygen deficiency in hafnium oxide films intentionally. The films were characterized by X-ray and magnetic measurements. X-ray diffraction studies show an increase in lattice parameter with increasing oxygen deficiency. Oxygen deficient hafnium oxide thin films also showed a decreasing bandgap with increase in oxygen deficiency. The magnetisation studies carried out with SQUID did not show any sign of ferromagnetism in the whole oxygen deficiency range. X-ray magnetic circular dichroism measurements also confirmed the absence of ferromagnetism in oxygen deficient hafnium oxide thin films.

  7. Hafnium carbide formation in oxygen deficient hafnium oxide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Rodenbücher, C. [Forschungszentrum Jülich GmbH, Peter Grünberg Institute (PGI-7), JARA-FIT, 52425 Jülich (Germany); Hildebrandt, E.; Sharath, S. U.; Kurian, J.; Komissinskiy, P.; Alff, L. [Technische Universität Darmstadt, Institute of Materials Science, 64287 Darmstadt (Germany); Szot, K. [Forschungszentrum Jülich GmbH, Peter Grünberg Institute (PGI-7), JARA-FIT, 52425 Jülich (Germany); University of Silesia, A. Chełkowski Institute of Physics, 40-007 Katowice (Poland); Breuer, U. [Forschungszentrum Jülich GmbH, Central Institute for Engineering, Electronics and Analytics (ZEA-3), 52425 Jülich (Germany); Waser, R. [Forschungszentrum Jülich GmbH, Peter Grünberg Institute (PGI-7), JARA-FIT, 52425 Jülich (Germany); RWTH Aachen, Institute of Electronic Materials (IWE 2), 52056 Aachen (Germany)

    2016-06-20

    On highly oxygen deficient thin films of hafnium oxide (hafnia, HfO{sub 2−x}) contaminated with adsorbates of carbon oxides, the formation of hafnium carbide (HfC{sub x}) at the surface during vacuum annealing at temperatures as low as 600 °C is reported. Using X-ray photoelectron spectroscopy the evolution of the HfC{sub x} surface layer related to a transformation from insulating into metallic state is monitored in situ. In contrast, for fully stoichiometric HfO{sub 2} thin films prepared and measured under identical conditions, the formation of HfC{sub x} was not detectable suggesting that the enhanced adsorption of carbon oxides on oxygen deficient films provides a carbon source for the carbide formation. This shows that a high concentration of oxygen vacancies in carbon contaminated hafnia lowers considerably the formation energy of hafnium carbide. Thus, the presence of a sufficient amount of residual carbon in resistive random access memory devices might lead to a similar carbide formation within the conducting filaments due to Joule heating.

  8. Are macroinvertebrates in high altitude streams affected by oxygen deficiency?

    DEFF Research Database (Denmark)

    Jacobsen, Dean; Rostgaard, S.; Vásconez, J. J.

    2003-01-01

    1. The solubility of oxygen in water increases with decreasing temperature. This has led to a general perception of cold, high mountain streams as more oxygen rich than warmer lowland streams, and that macroinvertebrates inhabiting high altitude streams have had no need to adapt to critical oxygen...... conditions. However, this fails to take into account that oxygen solubility declines with decreasing atmospheric pressure, which may be of importance at high altitudes. 2. Based on samples of macroinvertebrate benthos and in situ measurements of respiratory oxygen demand of macroinvertebrates in small...... the mean weight-specific respiratory rate of macroinvertebrates declined by only 50%, from 400 to 3800 m. We suggest that this disproportionately large gap between availability and demand of oxygen at high altitudes may imply a potential oxygen deficiency for the fauna, and we discuss how oxygen deficiency...

  9. Thermal conductivity reduction in oxygen-deficient strontium titanates

    NARCIS (Netherlands)

    Yu, Choongho; Scullin, Matthew L.; Huijben, Mark; Ramesh, Ramamoorthy; Majumdar, Arun

    2008-01-01

    We report significant thermal conductivity reduction in oxygen-deficient lanthanum-doped strontium titanate (Sr1−xLaxTiO3−δ) films as compared to unreduced strontium titanates. Our experimental results suggest that the oxygen vacancies could have played an important role in the reduction. This could

  10. Oxygen deficiency at CERN: Hazards, risks & mitigation measures

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    Compressed and liquified gases are used at many places at CERN. If they are introduced to the atmosphere, they can present an oxygen deficiency hazard (ODH) and lead to reduced abilities, unconsciousness or even death. The CERN method for ODH risk assessments is done on a case-by-case basis as each situation is unique. It is crucial to make sure the personnel can evacuate safely in case of an ODH situation. My talk will explain human reactions to reduced oxygen levels and I will give some practical examples on how one can assess and control the hazards from a possible oxygen deficient atmosphere. Some real accidents involving oxygen deficiency will also be mentioned.

  11. Ethanol flame synthesis of carbon nanotubes in deficient oxygen environments

    Science.gov (United States)

    Hu, Wei-Chieh; Lin, Ta-Hui

    2016-04-01

    In this study, carbon nanotubes (CNTs) were synthesized using ethanol diffusion flames in a stagnation-flow system composed of an upper oxidizer duct and a lower liquid pool. In the experiments, a gaseous mixture of oxygen and nitrogen flowed from the upper oxidizer duct, and then impinged onto the vertically aligned ethanol pool to generate a planar and steady diffusion flame in a deficient oxygen environment. A nascent nickel mesh was used as the catalytic metal substrate to collect deposited materials. The effect of low oxygen concentration on the formation of CNTs was explored. The oxygen concentration significantly influenced the flame environment and thus the synthesized carbon products. Lowering the oxygen concentration increased the yield, diameter, and uniformity of CNTs. The optimal operating conditions for CNT synthesis were an oxygen concentration in the range of 15%-19%, a flame temperature in the range of 460 °C-870 °C, and a sampling position of 0.5-1 mm below the upper edge of the blue flame front. It is noteworthy that the concentration gradient of C2 species and CO governed the CNT growth directly. CNTs were successfully fabricated in regions with uniform C2 species and CO distributions.

  12. High-temperature vaporization behavior of oxygen-deficient thoria

    International Nuclear Information System (INIS)

    Ackermann, R.J.; Tetenbaum, M.

    1979-01-01

    The experimental results of the present study on the vaporization behavior of oxygen-deficient thoria are directed toward a more precise and detailed study of the lower phase boundary (l.p.b.) and congruently vaporizing composition (c.v.c), and intermediate compositions, and the corresponding oxygen potentials and total pressure at temperatures above 2000K. The l.p.b. and c.v.c. values were found to fit an equation of the form log x = A + (B/T), where x is the stoichiometric defect in ThO 2 -x. Oxygen potentials corresponding to the l.p.b. and c.v.c. have been estimated from vapor pressures and thermodynamic data. A very sharp decrease in oxygen potential occurs when thoria isreduced only slightly from the stoichiometric composition. In the temperature range from 2400 to 2655 K, the oxygen partial pressure dependency of x in ThO 2 -x was found to be approximately proportional to PO 2 - 1 /4to PO 2 - 1 /. The small extent of reduction over a wide range of oxygen potentials at these temperatures is a clear illustration of the higher stability of the ThO 2 -x phase compared with that of UO 2 -x. Values of ΔHO 2 and ΔSO 2 have been estimated for selected compositions from the dependence of the measured oxygen potential on temperature. Estimates of the standard free energy of formation of bivariant ThO 2 -x compositions have been made. A substantial increase in the total pressure of thorium-bearing species occurs when stoichiometric thoria is reduced toward the lower phase boundary. (orig.) [de

  13. Persistent optically induced magnetism in oxygen-deficient strontium titanate.

    Science.gov (United States)

    Rice, W D; Ambwani, P; Bombeck, M; Thompson, J D; Haugstad, G; Leighton, C; Crooker, S A

    2014-05-01

    Strontium titanate (SrTiO3) is a foundational material in the emerging field of complex oxide electronics. Although its bulk electronic and optical properties are rich and have been studied for decades, SrTiO3 has recently become a renewed focus of materials research catalysed in part by the discovery of superconductivity and magnetism at interfaces between SrTiO3 and other non-magnetic oxides. Here we illustrate a new aspect to the phenomenology of magnetism in SrTiO3 by reporting the observation of an optically induced and persistent magnetization in slightly oxygen-deficient bulk SrTiO3-δ crystals using magnetic circular dichroism (MCD) spectroscopy and SQUID magnetometry. This zero-field magnetization appears below ~18 K, persists for hours below 10 K, and is tunable by means of the polarization and wavelength of sub-bandgap (400-500 nm) light. These effects occur only in crystals containing oxygen vacancies, revealing a detailed interplay between magnetism, lattice defects, and light in an archetypal complex oxide material.

  14. Measuring oxidation processes: Atomic oxygen flux monitor

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Of the existing 95 high-energy accelerators in the world, the Stanford Linear Collider (SLC) at the Stanford Linear Accelerator Center (SLAC) is the only one of the linear-collider type, where electrons and positrons are smashed together at energies of 50 GeV using linear beams instead of beam rings for achieving interactions. Use of a collider eliminates energy losses in the form of x-rays due to the curved trajectory of the rings, a phenomena known as bremsstrauhlung. Because these losses are eliminated, higher interaction energies are reached. Consequently the SLC produced the first Z particle in quantities large enough to allow measurement of its physical properties with some accuracy. SLAC intends to probe still deeper into the structure of matter by next polarizing the electrons in the beam. The surface of the source for these polarized particles, typically gallium arsenide, must be kept clean of contaminants. One method for accomplishing this task requires the oxidation of the surface, from which the oxidized contaminants are later boiled off. The technique requires careful measurement of the oxidation process. SLAC researchers have developed a technique for measuring the atomic oxygen flux in this process. The method uses a silver film on a quartz-crystal, deposition-rate monitor. Measuring the initial oxidation rate of the silver, which is proportional to the atomic oxygen flux, determines a lower limit on that flux in the range of 10 13 to 10 17 atoms per square centimeter per second. Furthermore, the deposition is reversible by exposing the sensor to atomic hydrogen. This technique has wider applications to processes in solid-state and surface physics as well as surface chemistry. In semiconductor manufacturing where a precise thickness of oxide must be deposited, this technique could be used to monitor the critical flux of atomic oxygen in the process

  15. Holographic monitoring of spatial distributions of singlet oxygen in water

    Science.gov (United States)

    Belashov, A. V.; Bel'tyukova, D. M.; Vasyutinskii, O. S.; Petrov, N. V.; Semenova, I. V.; Chupov, A. S.

    2014-12-01

    A method for monitoring spatial distributions of singlet oxygen in biological media has been developed. Singlet oxygen was generated using Radachlorin® photosensitizer, while thermal disturbances caused by nonradiative deactivation of singlet oxygen were detected by the holographic interferometry technique. Processing of interferograms yields temperature maps that characterize the deactivation process and show the distribution of singlet oxygen species.

  16. Seasonal oxygen deficiency over the western continental shelf of India

    Digital Repository Service at National Institute of Oceanography (India)

    Naqvi, S.W.A.; Naik, H.; Jayakumar, D.A.; Shailaja, M.S.; Narvekar, P.V.

    , and their impact on biology and chemistry off the west coast of India are described here. The O2 deficiency in this region, associated with the seasonal (southwest monsoon) upwelling, seems to have intensified in recent years, presumably in response to enhanced...

  17. Spatially monitoring oxygen level in 3D microfabricated cell culture systems using optical oxygen sensing beads

    OpenAIRE

    Wang, Lin; Acosta, Miguel A.; Leach, Jennie B.; Carrier, Rebecca L.

    2013-01-01

    Capability of measuring and monitoring local oxygen concentration at the single cell level (tens of microns scale) is often desirable but difficult to achieve in cell culture. In this study, biocompatible oxygen sensing beads were prepared and tested for their potential for real-time monitoring and mapping of local oxygen concentration in 3D micro-patterned cell culture systems. Each oxygen sensing bead is composed of a silica core loaded with both an oxygen sensitive Ru(Ph2phen3)Cl2 dye and ...

  18. Effect of oxygen deficiency on electronic properties and local structure of amorphous tantalum oxide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Denny, Yus Rama [Department of Physics Education, University of Sultan Ageng Tirtayasa, Banten 42435 (Indonesia); Firmansyah, Teguh [Department of Electrical Engineering, University of Sultan Ageng Tirtayasa, Banten 42435 (Indonesia); Oh, Suhk Kun [Department of Physics, Chungbuk National University, Cheongju 28644 (Korea, Republic of); Kang, Hee Jae, E-mail: hjkang@cbu.ac.kr [Department of Physics, Chungbuk National University, Cheongju 28644 (Korea, Republic of); Yang, Dong-Seok [Department of Physics Education, Chungbuk National University, Cheongju 28644 (Korea, Republic of); Heo, Sung; Chung, JaeGwan; Lee, Jae Cheol [Analytical Engineering Center, Samsung Advanced Institute of Technology, Suwon 16678 (Korea, Republic of)

    2016-10-15

    Highlights: • The effect of oxygen flow rate on electronic properties and local structure of tantalum oxide thin films was studied. • The oxygen deficiency induced the nonstoichiometric state a-TaOx. • A small peak at 1.97 eV above the valence band side appeared on nonstoichiometric Ta{sub 2}O{sub 5} thin films. • The oxygen flow rate can change the local electronic structure of tantalum oxide thin films. - Abstract: The dependence of electronic properties and local structure of tantalum oxide thin film on oxygen deficiency have been investigated by means of X-ray photoelectron spectroscopy (XPS), Reflection Electron Energy Loss Spectroscopy (REELS), and X-ray absorption spectroscopy (XAS). The XPS results showed that the oxygen flow rate change results in the appearance of features in the Ta 4f at the binding energies of 23.2 eV, 24.4 eV, 25.8, and 27.3 eV whose peaks are attributed to Ta{sup 1+}, Ta{sup 2+}, Ta{sup 3+}/Ta{sup 4+}, and Ta{sup 5+}, respectively. The presence of nonstoichiometric state from tantalum oxide (TaOx) thin films could be generated by the oxygen vacancies. In addition, XAS spectra manifested both the increase of coordination number of the first Ta-O shell and a considerable reduction of the Ta-O bond distance with the decrease of oxygen deficiency.

  19. Spatially monitoring oxygen level in 3D microfabricated cell culture systems using optical oxygen sensing beads.

    Science.gov (United States)

    Wang, Lin; Acosta, Miguel A; Leach, Jennie B; Carrier, Rebecca L

    2013-04-21

    Capability of measuring and monitoring local oxygen concentration at the single cell level (tens of microns scale) is often desirable but difficult to achieve in cell culture. In this study, biocompatible oxygen sensing beads were prepared and tested for their potential for real-time monitoring and mapping of local oxygen concentration in 3D micro-patterned cell culture systems. Each oxygen sensing bead is composed of a silica core loaded with both an oxygen sensitive Ru(Ph2phen3)Cl2 dye and oxygen insensitive Nile blue reference dye, and a poly-dimethylsiloxane (PDMS) shell rendering biocompatibility. Human intestinal epithelial Caco-2 cells were cultivated on a series of PDMS and type I collagen based substrates patterned with micro-well arrays for 3 or 7 days, and then brought into contact with oxygen sensing beads. Using an image analysis algorithm to convert florescence intensity of beads to partial oxygen pressure in the culture system, tens of microns-size oxygen sensing beads enabled the spatial measurement of local oxygen concentration in the microfabricated system. Results generally indicated lower oxygen level inside wells than on top of wells, and local oxygen level dependence on structural features of cell culture surfaces. Interestingly, chemical composition of cell culture substrates also appeared to affect oxygen level, with type-I collagen based cell culture systems having lower oxygen concentration compared to PDMS based cell culture systems. In general, results suggest that oxygen sensing beads can be utilized to achieve real-time and local monitoring of micro-environment oxygen level in 3D microfabricated cell culture systems.

  20. Effect of oxygen deficiency on the magnetic field-dependent entropy ...

    Indian Academy of Sciences (India)

    Moreover, to account for the applicability of the theory at high field, we have incorporated the effect of vortex overlapping in the London theory done by Nanda (1995). Here, we have presented the variation of change in entropy (S) with magnetic field for different oxygen deficiencies = 0, 0.04, and 0.06. On comparison ...

  1. Ordered oxygen deficient '112'perovskites, LnBaCo2 O5⋅ 50 ...

    Indian Academy of Sciences (India)

    ... Refresher Courses · Symposia · Live Streaming. Home; Journals; Bulletin of Materials Science; Volume 32; Issue 3. Ordered oxygen deficient '112' perovskites, LnBaCo2O5.50+: complex magnetism and transport properties. B Raveau Md Motin Seikh V Pralong V Caignaert. Volume 32 Issue 3 June 2009 pp 305-312 ...

  2. Deficient by oxygen perovskites and superconductor with transition temperature 93 K

    International Nuclear Information System (INIS)

    Ross, N.L.; Angel, R.J.; Finger, L.W.; Hazen, R.M.; Prewitt, K.T.

    1988-01-01

    Structural changes in some perovskites deficient by oxygen is reviewd. The structure of the high-temperature YBa 2 Cu 3 O 7-x superconductor is shown to develop usual for perovskites properties and at the same time to possess specific features. The specific feature includes the fact that ordering of vacancies and oxygen atoms is the consequence of Ba 2+ and Y 3+ ordering in positions A. Such ordering causes the removal of oxygen atoms plane from the structure and accurrence of pyramidal-coordinated atoms Cu2 in positions B. 22 refs.; 3 figs.; 2 tabs

  3. Dinitrogen Fixation Within and Adjacent to Oxygen Deficient Waters of the Eastern Tropical South Pacific Ocean

    Science.gov (United States)

    Widner, B.; Mulholland, M. R.; Bernhardt, P. W.; Chang, B. X.; Jayakumar, A.

    2016-02-01

    Recent work suggests that planktonic diazotrophs are geographically more widely distributed than previously thought including relatively warm (14-23oC) aphotic oxygenated pelagic waters and in aphotic waters within oxygen deficient zones. Because the volume of aphotic water in the ocean is large and may increase in the future, if dinitrogen (N2) fixation is widely occurring at sub-euphotic depths, this could result in a dramatic upward revision of global nitrogen (N) inputs via this process. N2 fixation rates were measured during a cruise in the Eastern Tropical South Pacific using stable isotope tracer techniques that account for slow gas dissolution. Results are compared with light, nutrient, and oxygen gradients (and necessarily temperature gradients). In addition, rates of N2 fixation made in vertical profiles within and above oxygen deficient waters are compared with those measured in vertical profiles adjacent to oxygen deficient waters. Results suggest that while rates of N2 fixation were measurable in deeper anoxic waters, volumetric N2 fixation rates were higher in surface waters.

  4. Crew Cerebral Oxygen Monitor, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR proposal is aimed at developing a non-invasive, optical method for monitoring the state of consciousness of crew members in operational...

  5. Crew Cerebral Oxygen Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase II SBIR proposal is aimed at developing a non-invasive, optical method for monitoring crew member state of awareness in operational environments. All...

  6. Monitoring bioremediation of weathered diesel NAPL using oxygen depletion profiles

    International Nuclear Information System (INIS)

    Davis, G.B.; Johnston, C.D.; Patterson, B.M.; Barber, C.; Bennett, M.

    1995-01-01

    Semicontinuous logging of oxygen concentrations at multiple depths has been used to evaluate the progress of an in situ bioremediation trial at a site contaminated by weathered diesel nonaqueous-phase liquid (NAPL). The evaluation trial consisted of periodic addition of nutrients and aeration of a 100-m 2 trial plot. During the bioremediation trial, aeration was stopped periodically, and decreases in dissolved and gaseous oxygen concentrations were monitored using data loggers attached to in situ oxygen sensors placed at multiple depths above and within a thin NAPL-contaminated zone. Oxygen usage rate coefficients were determined by fitting zero- and first-order rate equations to the oxygen depletion curves. For nutrient-amended sites within the trial plot, estimates of oxygen usage rate coefficients were significantly higher than estimates from unamended sites. These rates also converted to NPL degradation rates, comparable to those achieved in previous studies, despite the high concentrations and weathered state of the NAPL at this test site

  7. A fibre-optic oxygen sensor for monitoring human breathing

    International Nuclear Information System (INIS)

    Chen, Rongsheng; Formenti, Federico; Hahn, Clive E W; Farmery, Andrew D; Obeid, Andy

    2013-01-01

    The development and construction of a tapered-tip fibre-optic fluorescence based oxygen sensor is described. The sensor is suitable for fast and real-time monitoring of human breathing. The sensitivity and response time of the oxygen sensor were evaluated in vitro with a gas pressure chamber system, where oxygen partial pressure was rapidly changed between 5 and 15 kPa, and then in vivo in five healthy adult participants who synchronized their breathing to a metronome set at 10, 20, 30, 40, 50, and 60 breaths min –1 . A Datex Ultima medical gas analyser was used to monitor breathing rate as a comparator. The sensor's response time in vitro was less than 150 ms, which allows accurate continuous measurement of inspired and expired oxygen pressure. Measurements of breathing rate by means of our oxygen sensor and of the Datex Ultima were in strong agreement. The results demonstrate that the device can reliably resolve breathing rates up to 60 breaths min –1 , and that it is a suitable cost-effective alternative for monitoring breathing rates and end-tidal oxygen partial pressure in the clinical setting. The rapid response time of the sensor may allow its use for monitoring rapid breathing rates as occur in children and the newborn. (note)

  8. The nursing perspective on monitoring hemodynamics and oxygen transport.

    Science.gov (United States)

    Tucker, Dawn; Hazinski, Mary Fran

    2011-07-01

    Maintenance of adequate systemic oxygen delivery requires careful clinical assessment integrated with hemodynamic measurements and calculations to detect and treat conditions that may compromise oxygen delivery and lead to life-threatening shock, respiratory failure, or cardiac arrest. The bedside nurse constantly performs such assessments and measurements to detect subtle changes and trends in patient condition. The purpose of this editorial is to highlight nursing perspectives about the hemodynamic and oxygen transport monitoring systems summarized in the Pediatric Cardiac Intensive Care Society Evidence- Based Review and Consensus Statement on Monitoring of Hemodynamics and Oxygen Transport Balance. There is no substitute for the observations of a knowledgeable and experienced clinician who understands the patient's condition and potential causes of deterioration and is able to evaluate response to therapy.

  9. A fibre optic oxygen sensor for monitoring of human breathing

    Science.gov (United States)

    Chen, Rongsheng; Farmery, Andrew D.; Chen, Rui; Hahn, Clive E. W.

    2011-11-01

    A reliable and cost effective fibre optic oxygen sensor for monitoring of human breathing has been developed using a normal 200μm silica core/silica cladding optical fibre and a polymer sensing matrix. The fibre optic oxygen sensor is based on the fluorescence quenching of a fluorophore by oxygen. The sensing matrix, containing immobilized Pt(II) complexes, was coated at the end of the silica core/silica cladding optical fibre. The sensitivity and time response of the sensor were evaluated using the method of luminescence lifetime measurement. The polymer substrate influence on the time response of the sensor was improved by using a fibre taper design, and the response time of the optimized sensor was less than 200ms. This silica fibre based optic oxygen sensor is suitable for monitoring of patient breathing in intensive care unit in terms of safety and low cost.

  10. Oxygen deficiency in MoO{sub 3} polycrystalline nanowires and nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Varlec, Ana, E-mail: ana.varlec@ijs.si [Condensed Matter Physics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Arčon, Denis [Condensed Matter Physics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Faculty of Mathematics and Physics, University of Ljubljana, Jadranska cesta 19, SI-1000 Ljubljana (Slovenia); Škapin, Srečo D. [Advanced Materials Department, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Remškar, Maja [Condensed Matter Physics, Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia)

    2016-02-15

    We report on the synthesis of polycrystalline molybdenum oxide (MoO{sub 3}) nanowires via oxidation of molybdenum-sulfur-iodine (Mo{sub 6}S{sub 2}I{sub 8}) nanowires. This unique synthesis route results in an interesting morphology comprising porous nanowires and nanotubes. We found the nanowires to have the orthorhombic MoO{sub 3} structure. The structure is slightly oxygen deficient which results in the appearance of a new resonant Raman band (1004 cm{sup −1}) and paramagnetic defects (Mo{sup 5+}) of both the point and crystallographic shear plane nature. - Highlights: • Polycrystalline MoO{sub 3} nanowires were obtained via oxidation of Mo{sub 6}S{sub 2}I{sub 8} nanowires. • Nanowires are porous and tubular with either filled or empty interior. • Nanowires are slightly oxygen deficient which leads to a new Raman band.

  11. Molecular diversity of fungi from marine oxygen-deficient environments (ODEs)

    Digital Repository Service at National Institute of Oceanography (India)

    Manohar, C.S.; Forster, D.; Kauff, F.; Stoeck, T.

    . Sparrow Jr F K (1936) Biological observations of the marine fungi of woods hole waters. Biol Bull 70: 236-263. States JS & Christensen M (2001) Fungi Associated with Biological Soil Crusts in Desert Grasslands of Utah and Wyoming. Mycologia 93: 432... version: Biology of marine fungi. Ed. by: Raghukumar, C. (Prog. Mol. Subcellular Biol). Springer, vol.53 (Chap 10); 2012; 189-208 Chapter # 10 Molecular diversity of fungi from marine oxygen-deficient environments (ODEs) Cathrine S. Jebaraj 1...

  12. Simultaneous Monitoring of Vascular Oxygenation and Tissue Oxygen Tension of Breast Tumors Under Hyperbaric Oxygen Exposure

    Science.gov (United States)

    2008-04-01

    28. Alagoz, T., R. Buller, B. Anderson, K. Terrell , R...and oxygenation Ann . New Acad. Sci. 838 29–45 Chapman J D, Stobbe C C, Arnfield M R, Santus R, Lee J and McPhee M S 1991 Oxygen dependency of tumor

  13. Near-infrared spectroscopy for monitoring muscle oxygenation

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Piantadosi, C A

    2000-01-01

    Near-infrared spectroscopy (NIRS) is a non-invasive method for monitoring oxygen availability and utilization by the tissues. In intact skeletal muscle, NIRS allows semi-quantitative measurements of haemoglobin plus myoglobin oxygenation (tissue O2 stores) and the haemoglobin volume. Specialized...... algorithms allow assessment of the oxidation-reduction (redox) state of the copper moiety (CuA) of mitochondrial cytochrome c oxidase and, with the use of specific tracers, accurate assessment of regional blood flow. NIRS has demonstrated utility for monitoring changes in muscle oxygenation and blood flow...... during submaximal and maximal exercise and under pathophysiological conditions including cardiovascular disease and sepsis. During work, the extent to which skeletal muscles deoxygenate varies according to the type of muscle, type of exercise and blood flow response. In some instances, a strong...

  14. Magnetism and metal-insulator transition in oxygen deficient SrTiO3

    Science.gov (United States)

    Lopez-Bezanilla, Alejandro; Ganesh, P.; Littlewood, Peter

    2015-03-01

    We report new findings in the electronic structure and magnetism of oxygen vacancies in SrTiO3. By means of first-principles calculations we show that the appearance of magnetism in oxygen-deficient SrTiO3 is not determined solely by the presence of a single oxygen vacancy but by the density of free carriers and the relative proximity of the vacant sites. While an isolated vacancy behaves as a non-magnetic double donor, manipulation of the doping conditions allows the stability of a single donor state with emergent local moments. Strong local lattice distortions enhance the binding of this state. Consequently we find that the free-carrier density and strain are fundamental components to obtaining trapped spin-polarized electrons in oxygen-deficient SrTiO3, which may have important implications in the design of switchable magneto-optic devices. AL-B and PBL were supported by DOE-BES under Contract No. DE-AC02-06CH11357. PG was sponsored by the Laboratory Directed Research and Development Program of Oak Ridge National Laboratory, managed by UT- Battelle, LLC, for the US Department of Energy.

  15. Simultaneous Monitoring of Vascular Oxygenation and Tissue Oxygen Tension of Breast Tumors Under Hyperbaric Oxygen Exposure

    National Research Council Canada - National Science Library

    Xia, Mengna

    2005-01-01

    The goals of the study in the first stage are 1) to develop a mathematic model by which we can derive tumor blood flow and metabolic rate of oxygen from hemoglobin concentration during interventions, 2...

  16. Accumulation of Fe oxyhydroxides in the Peruvian oxygen deficient zone implies non-oxygen dependent Fe oxidation

    Science.gov (United States)

    Heller, Maija I.; Lam, Phoebe J.; Moffett, James W.; Till, Claire P.; Lee, Jong-Mi; Toner, Brandy M.; Marcus, Matthew A.

    2017-08-01

    Oxygen minimum zones (OMZs) have been proposed to be an important source of dissolved iron (Fe) into the interior ocean. However, previous studies in OMZs have shown a sharp decrease in total dissolved Fe (dFe) and/or dissolved Fe(II) (dFe(II)) concentrations at the shelf-break, despite constant temperature, salinity and continued lack of oxygen across the shelf-break. The loss of both total dFe and dFe(II) suggests a conversion of the dFe to particulate form, but studies that have coupled the reduction-oxidation (redox) speciation of both dissolved and particulate phases have not previously been done. Here we have measured the redox speciation and concentrations of both dissolved and particulate forms of Fe in samples collected during the U.S. GEOTRACES Eastern tropical Pacific Zonal Transect (EPZT) cruise in 2013 (GP16). This complete data set allows us to assess possible mechanisms for loss of dFe. We observed an offshore loss of dFe(II) within the oxygen deficient zone (ODZ), where dissolved oxygen is undetectable, accompanied by an increase in total particulate Fe (pFe). Total pFe concentrations were highest in the upper ODZ. X-ray absorption spectroscopy revealed that the pFe maximum was primarily in the Fe(III) form as Fe(III) oxyhydroxides. The remarkable similarity in the distributions of total particulate iron and nitrite suggests a role for nitrite in the oxidation of dFe(II) to pFe(III). We present a conceptual model for the rapid redox cycling of Fe that occurs in ODZs, despite the absence of oxygen.

  17. Evolution of Oxygen Deficiency Center on Fused Silica Surface Irradiated by Ultraviolet Laser and Posttreatment

    Directory of Open Access Journals (Sweden)

    Hai-Bing Lü

    2014-01-01

    Full Text Available Evolution of oxygen deficiency centers (ODCs on a fused silica surface irradiated using a 355 nm ultraviolet (UV laser beam in both vacuum and atmospheric conditions was quantitatively studied using photoluminescence and X-ray photoelectron spectroscopy. When the fusedsilica surface was exposed to the UV laser in vacuum, the laser damage threshold was decreased whereas the concentration of the ODCs was increased. For the fuse silica operated under the high power lasers, creation of ODCs on their surface resulted from the UV laser irradiation, and this is more severe in a high vacuum. The laser fluence and/or laser intensity have significant effects on the increase of the ODCs concentration. The ODCs can be effectively repaired using postoxygen plasma treatment and UV laser irradiation in an excessive oxygen environment. Results also demonstrated that the “gain” and “loss” of oxygen at the silica surface is a reversible and dynamic process.

  18. High-resolution spectra of stars in globular clusters. VI - Oxygen-deficient red giant stars in M13

    International Nuclear Information System (INIS)

    Brown, J.A.; Wallerstein, G.; Oke, J.B.

    1991-01-01

    From high-resolution, high signal-to-noise spectra, abundances of carbon, nitrogen, and oxygen and the C-12/C-13 ratio for five red giants in M13, including star II-67, which has previously been reported to be deficient in oxygen have been determined. Three of the five stars exhibit substantial oxygen deficiencies; O/Fe values range from +0.5 to less than about 0.3. The sum of the CNO nuclides is the same for all stars, which is interpreted as evidence that mixing of CNO-cycled material into the envelope is the cause of the variations in oxygen abundance. 41 refs

  19. Charge doping and large lattice expansion in oxygen-deficient heteroepitaxial WO3

    Science.gov (United States)

    Mattoni, Giordano; Filippetti, Alessio; Manca, Nicola; Zubko, Pavlo; Caviglia, Andrea D.

    2018-05-01

    Tungsten trioxide (WO3) is a versatile material with widespread applications ranging from electrochromics and optoelectronics to water splitting and catalysis of chemical reactions. For technological applications, thin films of WO3 are particularly appealing, taking advantage from a high surface-to-volume ratio and tunable physical properties. However, the growth of stoichiometric crystalline thin films is challenging because the deposition conditions are very sensitive to the formation of oxygen vacancies. In this paper, we show how background oxygen pressure during pulsed laser deposition can be used to tune the structural and electronic properties of WO3 thin films. By performing x-ray diffraction and low-temperature electrical transport measurements, we find changes in the WO3 lattice volume of up to 10% concomitantly with a resistivity drop of more than five orders of magnitude at room temperature as a function of increased oxygen deficiency. We use advanced ab initio calculations to describe in detail the properties of the oxygen vacancy defect states and their evolution in terms of excess charge concentration. Our results depict an intriguing scenario where structural, electronic, optical, and transport properties of WO3 single-crystal thin films can all be purposely tuned by controlling the oxygen vacancy formation during growth.

  20. Spatial sensitivity and penetration depth of three cerebral oxygenation monitors

    Science.gov (United States)

    Gunadi, Sonny; Leung, Terence S.; Elwell, Clare E.; Tachtsidis, Ilias

    2014-01-01

    The spatial sensitivities of NIRO-100, ISS Oximeter and TRS-20 cerebral oxygenation monitors are mapped using the local perturbation method to inform on their penetration depths and susceptibilities to superficial contaminations. The results show that TRS-20 has the deepest mean penetration depth and is less sensitive than the other monitors to a localized absorption change in the superficial layer. However, an integration time of more than five seconds is required by the TRS-20 to achieve an acceptable level of signal-to-noise ratio, which is the poorest amongst the monitors. With the exception of NIRO-100 continuous wave method, the monitors are not significantly responsive to layer-wide absorption change that occurs in the superficial layer. PMID:25401006

  1. Intracellular nitrate in sediments of an oxygen-deficient marine basin is linked to pelagic diatoms

    DEFF Research Database (Denmark)

    Kamp, Anja; Petro, Caitlin; Røy, Hans

    2018-01-01

    Intracellular nitrate is an important electron acceptor in oxygen-deficient aquatic environments, either for the nitrate-storing microbes themselves, or for ambient microbial communities through nitrate leakage. This study links the spatial distribution of intracellular nitrate with the abundance...... and identity of nitrate-storing microbes in sediments of the Bornholm Basin, an environmental showcase for severe hypoxia. Intracellular nitrate (up to 270 nmol cm−3 sediment) was detected at all 18 stations along a 35-km transect through the basin and typically extended as deep as 1.6 cm into the sediment...

  2. Monitoring Detrusor Oxygenation and Hemodynamics Noninvasively during Dysfunctional Voiding

    Science.gov (United States)

    Macnab, Andrew J.; Stothers, Lynn S.; Shadgan, Babak

    2012-01-01

    The current literature indicates that lower urinary tract symptoms (LUTSs) related to benign prostatic hyperplasia (BPH) have a heterogeneous pathophysiology. Pressure flow studies (UDSs) remain the gold standard evaluation methodology for such patients. However, as the function of the detrusor muscle depends on its vasculature and perfusion, the underlying causes of LUTS likely include abnormalities of detrusor oxygenation and hemodynamics, and available treatment options include agents thought to act on the detrusor smooth muscle and/or vasculature. Hence, near infrared spectroscopy (NIRS), an established optical methodology for monitoring changes in tissue oxygenation and hemodynamics, has relevance as a means of expanding knowledge related to the pathophysiology of BPH and potential treatment options. This methodological report describes how to conduct simultaneous NIRS monitoring of detrusor oxygenation and hemodynamics during UDS, outlines the clinical implications and practical applications of NIRS, explains the principles of physiologic interpretation of NIRS voiding data, and proposes an exploratory hypothesis that the pathophysiological causes underlying LUTS include detrusor dysfunction due to an abnormal hemodynamic response or the onset of oxygen debt during voiding. PMID:23019422

  3. Monitoring Detrusor Oxygenation and Hemodynamics Noninvasively during Dysfunctional Voiding

    Directory of Open Access Journals (Sweden)

    Andrew J. Macnab

    2012-01-01

    Full Text Available The current literature indicates that lower urinary tract symptoms (LUTSs related to benign prostatic hyperplasia (BPH have a heterogeneous pathophysiology. Pressure flow studies (UDSs remain the gold standard evaluation methodology for such patients. However, as the function of the detrusor muscle depends on its vasculature and perfusion, the underlying causes of LUTS likely include abnormalities of detrusor oxygenation and hemodynamics, and available treatment options include agents thought to act on the detrusor smooth muscle and/or vasculature. Hence, near infrared spectroscopy (NIRS, an established optical methodology for monitoring changes in tissue oxygenation and hemodynamics, has relevance as a means of expanding knowledge related to the pathophysiology of BPH and potential treatment options. This methodological report describes how to conduct simultaneous NIRS monitoring of detrusor oxygenation and hemodynamics during UDS, outlines the clinical implications and practical applications of NIRS, explains the principles of physiologic interpretation of NIRS voiding data, and proposes an exploratory hypothesis that the pathophysiological causes underlying LUTS include detrusor dysfunction due to an abnormal hemodynamic response or the onset of oxygen debt during voiding.

  4. μ+ SR study of antiferromagnetism and superconductivity in oxygen deficient YBa2Cu3Ox

    International Nuclear Information System (INIS)

    Brewer, J.H.; Carolan, J.; Chaklader, A.C.D.; Hardy, W.N.; Hayden, M.; Kaplan, N.; Kempton, J.; Kiefl, R.F.; Kreitzman, S.R.; Kulpa, A.; Luke, G.M.; Riseman, T.M.; Roehmer, G.; Schleger, P.; Williams, D.L.; Ansaldo, E.J.; Kossler, W.J.; Watanabe, Y.; Yamazaki, T.

    1987-12-01

    Positive muon spin rotation and relaxation (μ + SR) measurements of the oxygen-deficient perovskite YBa 2 Cu 3 O x have revealed local antiferromagnetic (AFM) order for 6.0 ≤ ∼ x ≤ ∼ 6.4 with a Neel temperature T N that decreases rapidly with increasing oxygen content x. For carefully annealed samples with 6.35 ≤ ∼ x ≤ ∼ 6.5 the superconducting (SC) transition temperature T C increases smoothly with x from 25 K at x=6.348 to 60 K at x=6.507. Two such samples with x = 6.348 and x = 6.400 seem to 'switch' from SC to AFM at low temperatures. (Author) (10 refs., 3 figs.)

  5. Study on the effects of fluorine and oxygen deficiency on YBa2Cu3O7 by ab initio method

    Institute of Scientific and Technical Information of China (English)

    刘洪霖; 曹晓卫; 瞿丽曼; 陈念贻

    1997-01-01

    The calculations of clusters modeling the fluorine-doping and oxygen deficiency of YBa2Cu3O2,have been performed by the method of all-electron ab initio Hartree-Fock with self-consistent crystal field Results show that in CuO planes electric charge significantly increases,the chemical valence of Cu decreases and the covalent bonding of Cu-O greatly weakens owing to oxygen deficiency,while the effect of F restores the local electronic structure of YBa2Cu3O7 The reported opinion that F occupied the oxygen vacancy in Cu-O chains seems disputable according to the calculated bonding characteristics.

  6. Lack of oxygen effect in glutathione-deficient human cells in culture

    International Nuclear Information System (INIS)

    Edgren, M.; Larsson, A.; Nilsson, K.; Revesz, L.; Scott, O.C.A.

    1980-01-01

    The frequency of X-ray-induced DNA breaks was determined in human cell lines which are deficient in glutathione synthetase and have a greatly reduced glutathione content. Hydroxyapatite chromatography was used for the estimation of the DNA breaks in cell cultures, which were derived either from lymphoblasts transformed by infection with EB virus or from fibroblasts. The dose-effect relationship for the induction of breaks when radiation exposure was made in argon, was similar to that found when exposure was made in air. In control cultures with normal glutathione content, the induction of breaks was enhanced when irradiation was made under aerobic, instead of anaerobic, conditions. Treatment of the glutathione-deficient cells with the hypoxic radiosensitizer misonidazole did not enhance the induction of breaks by radiation delivered either in air or in argon. In control cultures, radiation induction of breaks was enhanced by misonidazole under anaerobic but not under aerobic conditions. When the glutathione-deficient cells were pretreated with cysteamine however, irradiation in the absence of oxygen resulted in a decreased frequency of DNA breaks. (author)

  7. Retrievable micro-inserts containing oxygen sensors for monitoring tissue oxygenation using EPR oximetry

    International Nuclear Information System (INIS)

    Dinguizli, M; Beghein, N; Gallez, B

    2008-01-01

    Tissue oxygenation is a crucial parameter in various physiopathological situations and can influence the therapeutic response of tumours. EPR oximetry is a reliable method for assessing and monitoring oxygen levels in vivo over long periods of time. Among the different paramagnetic oxygen sensors available for EPR oximetry, lithium phthalocyanine (LiPc) is a serious candidate for in vivo applications because of its narrow linewidth and its high signal-to-noise ratio. To enhance the biocompatibility of the sensors, fluoropolymer Teflon AF2400 was used to make cylindrical micro-inserts containing LiPc crystals. This new micro-pellet design has several advantages for in vivo studies, including the possibility of being able to choose the implant size, a high sensor content, the facility of in vivo insertion and complete protection with preservation of the oxygen sensor's characteristics. The response to oxygen and the kinetics of this response were tested using in vivo EPR: no differences were observed between micro-inserts and uncoated LiPc crystals. Pellets implanted in vivo in muscles conserved their responsiveness over a long period of time (∼two months), which is much longer than the few days of stability observed using LiPc crystals without protection by the implant. Finally, evaluation of the biocompatibility of the implants revealed no inflammatory reaction around the implantation area

  8. Synthesis of surface oxygen-deficient BiPO{sub 4} nanocubes with enhanced visible light induced photocatalytic activity

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Bingtao; Yin, Haoyong; Li, Tao; Gong, Jianying; Lv, Shumei; Nie, Qiulin, E-mail: yhy@hdu.edu.cn [College of Materials & Environmental Engineering, Hangzhou Dianzi University, Hangzhou (China)

    2017-05-15

    The visible light driven BiPO{sub 4} nanocubes with sufficient surface oxygen deficiency were fabricated by a hydrothermal process and subsequently ultrasonic assistant Fe reduction process. The products were characterized by XRD, DRS, XPS, SEM and TEM which showed that the BiPO{sub 4} had cuboid-like shape with a smooth surface and clear edges and the oxygen vacancies were successfully introduced on the surface of the BiPO{sub 4} nanocubes. The as prepared oxygen-deficient BiPO{sub 4} nanocubes showed greatly enhanced visible light induced photocatalytic activity in degradation of Rhodamine B. The enhanced photocatalytic performance and expanded visible light response of BiPO{sub 4} may be due to the introduction of surface oxygen vacancies which can generate the oxygen vacancies mid-gap states lower to the conduction band of BiPO{sub 4}. (author)

  9. Bridge health monitoring metrics : updating the bridge deficiency algorithm.

    Science.gov (United States)

    2009-10-01

    As part of its bridge management system, the Alabama Department of Transportation (ALDOT) must decide how best to spend its bridge replacement funds. In making these decisions, ALDOT managers currently use a deficiency algorithm to rank bridges that ...

  10. Oxygen Stoichiometry in Cation Deficient (La,Sr)_{1-z}MnO_3 SOFC Cathode Materials

    DEFF Research Database (Denmark)

    Zachau-Christiansen, Birgit; Jacobsen, Torben; Skaarup, Steen

    1997-01-01

    by the imposed potential.It is found that the oxygen stoichiometry and hence the defect chemistry is different whether A-site charge deficiency is established by Sr-doping or by A-site vacancies. Furthermore,A-site deficient lanthanum strontium manganates expel a secondary phase of manganese oxide when exposed...... to low oxygen partial pressures. The presence of small amounts of secondary phase isobserved and identified by its reoxidation peak. The amount of this foreign phase is determined by the charge used for its oxidation....

  11. A study on oxygen-deficient YBa2Cu3O7-δ superconductors by positron lifetime spectroscopy

    International Nuclear Information System (INIS)

    Zhang Jincang; Liu Fengqi; Liu Junzheng; Cao Shixun; Cheng Guosheng

    1995-01-01

    Positron lifetime spectroscopy has been used for studying various oxygen-deficient YBa 2 Cu 3 O 7 - δ (δ = 0.06-0.68) at normal state (300 K) and Superconducting state (77 K). Using the two-state trapping model, the experimental results were analysed and there exists a typical positron annihilation characteristics in this systems. The local electron density n e and vacancy concentration C v are calculated as a function of oxygen-deficiency δ. The mechanism of positron annihilation and the correlation with superconductivity are also discussed

  12. Oxygen-deficient hematite nanorods as high-performance and novel negative electrodes for flexible asymmetric supercapacitors.

    Science.gov (United States)

    Lu, Xihong; Zeng, Yinxiang; Yu, Minghao; Zhai, Teng; Liang, Chaolun; Xie, Shilei; Balogun, Muhammad-Sadeeq; Tong, Yexiang

    2014-05-21

    Oxygen-deficient α-Fe2 O3 nanorods with outstanding capacitive performance are developed and demonstrated as novel negative electrodes for flexible asymmetric supercapacitors. The asymmetric-supercapacitor device based on the oxygen-deficient α-Fe2 O3 nanorod negative electrode and a MnO2 positive electrode achieves a maximum energy density of 0.41 mW·h/cm(3) ; it is also capable of charging a mobile phone and powering a light-emitting diode indicator. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Distribution and Magnitude of Dinitrogen Fixation in the Eastern Tropical North Pacific Oxygen Deficient Zone.

    Science.gov (United States)

    Selden, C.; Mulholland, M. R.; Widner, B.; Bernhardt, P. W.; Macías Tapia, A.; Jayakumar, A.

    2016-12-01

    The Eastern Tropical North Pacific Ocean (ETNP) hosts one of the world's three major open ocean oxygen deficient zones (ODZs). Hotspots for fixed nitrogen (N) loss processes, ODZs have classically been discounted as areas of significant dinitrogen (N2) fixation, the microbe-mediated reduction of N2 to ammonium (NH4+), which has historically been ascribed primarily to euphotic, nutrient-deplete tropical waters. Challenging this paradigm, active expression of nifH (the dinitrogen reductase structural gene) has recently been documented in the ETNP, Eastern Tropical South Pacific, and Arabian Sea ODZs, implying a closer coupling of fixed nitrogen input and loss processes than previously thought. Here, we report rates of N­2 fixation measured in the ETNP ODZ along vertical gradients of oxygen, light, and dissolved N concentrations. Detailed vertical profiles of N2 fixation rates and dissolved N concentrations made within the ODZ were compared with similar profiles from oxic waters outside the ODZ. In addition, different organic carbon sources were investigated as potential rate-limiting factors for N2 fixation in sub-euphotic waters. By establishing the magnitude and distribution of N­2 fixation in the ETNP ODZ, this study contributes to current understanding of N cycling in anoxic and aphotic waters, and serves to elucidate nuances in the global N budget, enabling more accurate biogeochemical modeling. Understanding these processes in present day ODZs is crucial for predicting how ongoing anthropogenic intensification of coastal ODZs will alter biogeochemical cycles in the future.

  14. Mechanical control of magnetism in oxygen deficient perovskite SrTiO3.

    Science.gov (United States)

    Zhang, Yajun; Wang, Jie; Sahoo, M P K; Shimada, Takahiro; Kitamura, Takayuki

    2015-10-28

    Mechanical control of magnetism in perovskite oxides is an important and promising approach in spintronics. Based on the first-principles calculations, we demonstrate that a negative pressure leads to a great enhancement of magnetic moment in deficient SrTiO3 with oxygen vacancies, whereas a positive pressure results in the gradual disappearance of magnetism. Spin charge density, Bader charge analysis and electronic density of states successfully elucidate the origin and underlying physics of the enhancement and disappearance of magnetism. It is found that the split electronic states of dz(2), dyz and dzx in the 3d orbitals of Ti atoms remarkably contribute to the occupancy of majority spin states under negative pressure, which induces a large magnetic moment. Under positive pressure, however, the equal occupancy of both majority and minority t2g and eg states leads to the disappearance of magnetization. In addition, both negative and positive pressures can largely lower the vacancy formation enthalpy, suggesting that the oxygen vacancy is preferable with pressure. Our findings may provide a mechanism to achieve the pressure control of magnetization in nonmagnetic perovskite oxides.

  15. Facile Aluminum Reduction Synthesis of Blue TiO2 with Oxygen Deficiency for Lithium-Ion Batteries.

    Science.gov (United States)

    Zheng, Jing; Ji, Guangbin; Zhang, Peng; Cao, Xingzhong; Wang, Baoyi; Yu, Linghui; Xu, Zhichuan J

    2015-12-07

    An ultrafacile aluminum reduction method is reported herein for the preparation of blue TiO2 nanoparticles (donated as Al-TiO2 , anatase phase) with abundant oxygen deficiency for lithium-ion batteries. Under aluminum reduction, the morphology of the TiO2 nanosheets changes from well-defined rectangular into uniform round or oval nanoparticles and the particle size also decreases from 60 to 31 nm, which can aggressively accelerate the lithium-ion diffusion. Electron paramagnetic resonance (EPR) and positron annihilation lifetime spectroscopy (PALS) results reveal that plentiful oxygen deficiencies relative to the Ti(3+) species were generated in blue Al-TiO2 ; this effectively enhances the electron conductivity of the TiO2 . X-ray photoelectron spectrometry (XPS) analysis indicates that a small peak is observed for the Al-O bond, which probably plays a very important role in the stabilization of the oxygen deficiencies/Ti(3+) species. As a result, the blue Al-TiO2 possesses significantly higher capacity, better rate performance, and a longer cycle life than the white pure TiO2 . Such improvements can be attributed to the decreased particle size, as well as the existence of the oxygen deficiencies/Ti(3+) species. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. On the oxygen deficiency of high-Tc Y1Ba2Cu3O7-μ ceramics

    International Nuclear Information System (INIS)

    Szasz, A.; Dankhazi, Z.; Kojnok, J.; Trager, T.; Matrai, J.; Gyorgy, I.; Kirchmayr, H.; Mueller, H.; Watson, L.M.

    1991-01-01

    The role of oxygen deficiency in Y 1 Ba 2 Cu 3 O 7-μ ceramics was investigated by differential thermal analysis (DTA), differential thermogravimetry (DTG), linear thermal expansion (LTE), and by soft x-ray fluorescence spectroscopy (SXFS). The interdependence of the measured parameters and some of the stability criteria are discussed

  17. Positron-annihilation study of oxygen-deficient YBa2Cu3Ox (6.3

    International Nuclear Information System (INIS)

    Tang, C.Q.; Li, B.R.; Chen, A.

    1990-01-01

    We have measured the positron-lifetime spectra of oxygen-deficient YBa 2 Cu 3 O x for 6.3 m , τ 1 , τ 2 , and I 2 have a significant oxygen-content dependence. It is suggested that there are many kinds of positron states in polycrystalline YBa 2 Cu 3 O x , the disordering of O(1) vacancies strongly affects positron lifetime, and with gradually decreasing x the average electronic density decreases and the configuration and/or the charge states of the oxygen vacancies change in the region containing Cu(1)-O(1) chains

  18. TrxR2 deficiencies promote chondrogenic differentiation and induce apoptosis of chondrocytes through mitochondrial reactive oxygen species

    International Nuclear Information System (INIS)

    Yan, Jidong; Xu, Jing; Fei, Yao; Jiang, Congshan; Zhu, Wenhua; Han, Yan; Lu, Shemin

    2016-01-01

    Thioredoxin reductase 2 (TrxR2) is a selenium (Se) containing protein. Se deficiency is associated with an endemic osteoarthropathy characterized by impaired cartilage formation. It is unclear whether TrxR2 have roles in cartilage function. We examined the effects of TrxR2 on chondrogenic ATDC5 cells through shRNA-mediated gene silencing of TrxR2. We demonstrated TrxR2 deficiencies could enhance chondrogenic differentiation and apoptosis of ATDC5 cells. TrxR2 deficiencies increased accumulation of cartilage glycosaminoglycans (GAGs) and mineralization. TrxR2 deficiencies also stimulated expression of extracellular (ECM) gene including Collagen II and Aggrecan. The enhanced chondrogenic properties were further confirmed by activation of Akt signaling which are required for chondrogenesis. In addition, TrxR2 deficiencies promoted chondrocyte proliferation through acceleration of cell cycle progression by increase in both S and G2/M phase cell distribution accompanied with induction of parathyroid hormone-related protein (PTHrP). Moreover, TrxR2 deficiencies induced chondrocyte death via apoptosis and increased cell sensitivity to exogenous oxidative stress. Furthermore, TrxR2 deficiencies induced emission of mitochondrial reactive oxygen species (ROS) without alteration of mitochondrial membrane potential and intracellular ATP content. Finally, treatment of TrxR2 deficiency cells with N-acetylcysteine (NAC) inhibited mitochondrial ROS production and chondrocyte apoptosis. NAC also prevented chondrogenic differentiation of TrxR2 deficiency cells by suppression of ECM gene expression, GAGs accumulation and mineralization, as well as attenuation of Akt signaling. Thus, TrxR2-mediated mitochondrial integrity is indispensable for chondrogenic differentiation of ATDC5 cells. TrxR2 deficiency-induced impaired proliferation and death of chondrocytes may be the pathological mechanism of the osteoarthropathy due to Se deficiency. Notably, this study also uncover the roles of

  19. TrxR2 deficiencies promote chondrogenic differentiation and induce apoptosis of chondrocytes through mitochondrial reactive oxygen species

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Jidong [Department of Human Anatomy, Histology and Embryology, School of Basic Medical Sciences, Xi’an Jiaotong University Health Science Center, Xi’an, Shaanxi 710061 (China); Xu, Jing [Department of Biochemistry and Molecular Biology, School of Basic Medical Sciences, Xi’an Jiaotong University Health Science Center, Xi’an, Shaanxi 710061 (China); Fei, Yao [College of Life Sciences, Northwest University, Xi’an, Shaanxi Province 710069 (China); Jiang, Congshan; Zhu, Wenhua; Han, Yan [Department of Biochemistry and Molecular Biology, School of Basic Medical Sciences, Xi’an Jiaotong University Health Science Center, Xi’an, Shaanxi 710061 (China); Lu, Shemin, E-mail: lushemin@xjtu.edu.cn [Department of Biochemistry and Molecular Biology, School of Basic Medical Sciences, Xi’an Jiaotong University Health Science Center, Xi’an, Shaanxi 710061 (China); Key Laboratory of Environment and Genes Related to Diseases, Xi’an Jiaotong University, Ministry of Education of China (China)

    2016-05-15

    Thioredoxin reductase 2 (TrxR2) is a selenium (Se) containing protein. Se deficiency is associated with an endemic osteoarthropathy characterized by impaired cartilage formation. It is unclear whether TrxR2 have roles in cartilage function. We examined the effects of TrxR2 on chondrogenic ATDC5 cells through shRNA-mediated gene silencing of TrxR2. We demonstrated TrxR2 deficiencies could enhance chondrogenic differentiation and apoptosis of ATDC5 cells. TrxR2 deficiencies increased accumulation of cartilage glycosaminoglycans (GAGs) and mineralization. TrxR2 deficiencies also stimulated expression of extracellular (ECM) gene including Collagen II and Aggrecan. The enhanced chondrogenic properties were further confirmed by activation of Akt signaling which are required for chondrogenesis. In addition, TrxR2 deficiencies promoted chondrocyte proliferation through acceleration of cell cycle progression by increase in both S and G2/M phase cell distribution accompanied with induction of parathyroid hormone-related protein (PTHrP). Moreover, TrxR2 deficiencies induced chondrocyte death via apoptosis and increased cell sensitivity to exogenous oxidative stress. Furthermore, TrxR2 deficiencies induced emission of mitochondrial reactive oxygen species (ROS) without alteration of mitochondrial membrane potential and intracellular ATP content. Finally, treatment of TrxR2 deficiency cells with N-acetylcysteine (NAC) inhibited mitochondrial ROS production and chondrocyte apoptosis. NAC also prevented chondrogenic differentiation of TrxR2 deficiency cells by suppression of ECM gene expression, GAGs accumulation and mineralization, as well as attenuation of Akt signaling. Thus, TrxR2-mediated mitochondrial integrity is indispensable for chondrogenic differentiation of ATDC5 cells. TrxR2 deficiency-induced impaired proliferation and death of chondrocytes may be the pathological mechanism of the osteoarthropathy due to Se deficiency. Notably, this study also uncover the roles of

  20. Superconductivity, structure and oxygen deficiency in the Ba2YCu2WOY system

    International Nuclear Information System (INIS)

    Bokhimi, M.; Portilla, M.; Perez, R.; Universidad Nacional Autonoma de Mexico, Mexico City

    1991-01-01

    It is shown that the Ba-2YCu x WO y system with O≤x≤2 is composed of 2 phases, the first with composition Ba 2 YWO 6 with a small copper-solution replacing yttrium, it has cubic ordered perovskite structure with the space group Fm3m, the solution of the copper gives rise to a lattice contraction. The second phase corresponds to CuO, or Cu 2 O depending on sample preparation At large copper concentrations the first phase appears as small precipitates embedded in the second one. Reducing the samples at 1150 o C in H 2 gives rise to a separation of the phases, segregating the copper in the form of liquid metal. The reduction eliminates from the first phase the dissolved copper, and produces also some oxygen deficiency in the sample, both effects give origin to a lattice distortion in the ordered perovskite structure. Although the samples are black after the reduction, they are not electrical conductors. (author). 8 refs., 8 figs

  1. Photoluminescence of Se-related oxygen deficient center in ion-implanted silica films

    International Nuclear Information System (INIS)

    Zatsepin, A.F.; Buntov, E.A.; Pustovarov, V.A.; Fitting, H.-J.

    2013-01-01

    The results of low-temperature time-resolved photoluminescence (PL) investigation of thin SiO 2 films implanted with Se + ions are presented. The films demonstrate an intensive PL band in the violet spectral region, which is attributed to the triplet luminescence of a new variant of selenium-related oxygen deficient center (ODC). The main peculiarity of the defect energy structure is the inefficient direct optical excitation. Comparison with spectral characteristics of isoelectronic Si-, Ge- and SnODCs show that the difference in electronic properties of the new center is related to ion size factor. It was established that the dominating triplet PL excitation under VUV light irradiation is related to the energy transfer from SiO 2 excitons. A possible model of Se-related ODC is considered. -- Highlights: • The low-temperature photoluminescence of thin SiO 2 films implanted with Se + ions was studied. • The 3.4 eV PL band was attributed to triplet luminescence of Se-related ODC. • The peculiarity of SeODC electronic properties is related to ion size factor. • The dominating VUV excitation of triplet PL is related to energy transfer from SiO 2 excitons. • A possible model of Se-related ODC is considered

  2. Monitoring cardiac output during hyperbaric oxygen treatment of haemodynamically unstable patients

    DEFF Research Database (Denmark)

    Hansen, Marco Bo; Treschow, Frederik; Skielboe, Martin

    2013-01-01

    Patients suffering from necrotizing fasciitis (NF) are often haemodynamically unstable and require extended monitoring of cardiovascular parameters; yet this is limited during hyperbaric oxygen treatment (HBOT). We aimed to evaluate the use and safety of transoesophageal Doppler (TED) monitoring ...

  3. Cardiomyocyte hypertrophy induced by Endonuclease G deficiency requires reactive oxygen radicals accumulation and is inhibitable by the micropeptide humanin.

    Science.gov (United States)

    Blasco, Natividad; Cámara, Yolanda; Núñez, Estefanía; Beà, Aida; Barés, Gisel; Forné, Carles; Ruíz-Meana, Marisol; Girón, Cristina; Barba, Ignasi; García-Arumí, Elena; García-Dorado, David; Vázquez, Jesús; Martí, Ramon; Llovera, Marta; Sanchis, Daniel

    2018-06-01

    The endonuclease G gene (Endog), which codes for a mitochondrial nuclease, was identified as a determinant of cardiac hypertrophy. How ENDOG controls cardiomyocyte growth is still unknown. Thus, we aimed at finding the link between ENDOG activity and cardiomyocyte growth. Endog deficiency induced reactive oxygen species (ROS) accumulation and abnormal growth in neonatal rodent cardiomyocytes, altering the AKT-GSK3β and Class-II histone deacethylases (HDAC) signal transduction pathways. These effects were blocked by ROS scavengers. Lack of ENDOG reduced mitochondrial DNA (mtDNA) replication independently of ROS accumulation. Because mtDNA encodes several subunits of the mitochondrial electron transport chain, whose activity is an important source of cellular ROS, we investigated whether Endog deficiency compromised the expression and activity of the respiratory chain complexes but found no changes in these parameters nor in ATP content. MtDNA also codes for humanin, a micropeptide with possible metabolic functions. Nanomolar concentrations of synthetic humanin restored normal ROS levels and cell size in Endog-deficient cardiomyocytes. These results support the involvement of redox signaling in the control of cardiomyocyte growth by ENDOG and suggest a pathway relating mtDNA content to the regulation of cell growth probably involving humanin, which prevents reactive oxygen radicals accumulation and hypertrophy induced by Endog deficiency. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Fatty acid binding protein 4 deficiency protects against oxygen-induced retinopathy in mice.

    Directory of Open Access Journals (Sweden)

    Magali Saint-Geniez

    Full Text Available Retinopathy of prematurity (ROP is a leading cause of blindness in children worldwide due to increasing survival rates of premature infants. Initial suppression, followed by increased production of the retinal vascular endothelial growth factor-A (VEGF expression are key events that trigger the pathological neovascularization in ROP. Fatty acid binding protein 4 (FABP4 is an intracellular lipid chaperone that is induced by VEGF in a subset of endothelial cells. FABP4 exhibits a pro-angiogenic function in cultured endothelial cells and in airway microvasculature, but whether it plays a role in modulation of retinal angiogenesis is not known. We hypothesized that FABP4 deficiency could ameliorate pathological retinal vascularization and investigated this hypothesis using a well-characterized mouse model of oxygen-induced retinopathy (OIR. We found that FABP4 was not expressed in retinal vessels, but was present in resident macrophages/microglial cells and endothelial cells of the hyaloid vasculature in the immature retina. While FABP4 expression was not required for normal development of retinal vessels, FABP4 expression was upregulated and localized to neovascular tufts in OIR. FABP4-/- mice demonstrated a significant decrease in neovessel formation as well as a significant improvement in physiological revascularization of the avascular retinal tissues. These alterations in retinal vasculature were accompanied by reduced endothelial cell proliferation, but no effect on apoptosis or macrophage/microglia recruitment. FABP4-/- OIR samples demonstrated decreased expression of genes involved in angiogenesis, such as Placental Growth Factor, and angiopoietin 2. Collectively, our findings suggest FABP4 as a potential target of pathologic retinal angiogenesis in proliferative retinopathies.

  5. Survival curves of irradiated glutathione-deficient human fibroblasts: indication of a reduced enhancement of radiosensitivity by oxygen and misonidazole

    International Nuclear Information System (INIS)

    Midander, J.; Deschavanne, P.J.; Malaise, E.P.; Revesz, L.

    1982-01-01

    Fibroblasts derived from a patient with 5-oxoprolinuria are genetically deficient in glutathione synthetase. This deficiency causes a dramatic decrease in intracellular glutathione (GSH) level. The radiosensitivity of GSH deficient cells (GSH) was studied in vitro using colony forming ability as an endpoint. Cells with normal GSH level, obtained from the healthy brother of the patient, were used as controls. When irradiated in 95% air-5% CO 2 , GSH - cells are slightly but significantly more radiosensitive than GSH + controls (dose modifying factor (DMF) of 1.2). When irradiated in argon, the survival curve of GSH - cells indicates an oxygen enhancement ratio (OER) of 1.5 when compared to the curve obtained in oxic conditions. The OER of control cells in the same conditions is 2.9. In comparison to results obtained in air, 100% oxygen moderately increases the radiosensitivity of GSH + cells (DMF 1,23), while it has a very low effect on GSH - cells (DMF 1.06). These results suggest that intracellular GSH plays an essential protective role in hypoxia, its effect is reduced in air and practically disappears in 100% oxygen. When cells are incubated with 8 mM misonidazole 2 hours before irradiation, the drug has a much greater sensitizing effect on GSH + cells (DMF 2.33) than on GSH - cells (DMF 1.55). The results demonstrate that intracellular GSH level plays a major role in the response of hypoxic cells, irradiated either alone or in the presence of misonidazole

  6. Oxygen enhancement ratios for glutathione-deficient human fibroblasts determined from the frequency of radiation induced micronuclei

    International Nuclear Information System (INIS)

    Midander, J.

    1982-01-01

    The yield of micronuclei (MN) was determined to study the radiosensitizing effect of oxygen on three human fibroblast strains, characterized by genetically defined differences in their glutathione (GSH) level. Cells were irradiated in paired experiments with x-ray doses of 2.66 and 6.65 gy in their exponential growth phase in a monolayer under oxic and anoxic conditions. Results indicated a reduced oxygen effect for the GSH deficient cells, the reduction of o.e.r. being most pronounced in the case of GSHsup(-/-) cells, when it was close to unity. The o.e.r. value was intermediate for the GSHsup(+/-) in comparison with the two other cell strains. It is concluded that the data indicate a correlation between the cellular content of GSH and the oxygen enhancement of the formation of micronuclei after irradiation. (U.K.)

  7. Monitoring and measurement of oxygen concentrations in liquid sodium

    International Nuclear Information System (INIS)

    Smith, D.L.

    1976-01-01

    The measurement of oxygen concentrations in sodium at levels of interest for LMFBR applications is reviewed. Additional data are presented to support the validity of the vanadium-equilibration method as a reference for determination of oxygen concentrations in sodium at levels equal to or less than 15 ppM. Operating experience with electrochemical oxygen meters that have a thoria-yttria electrolyte and a Na--Na 2 O reference electrode is described. Meter lifetimes in excess of one year have generally been achieved for operating temperatures of 352 and 402 0 C, and fairly stable emfs have been observed for periods of several months. 7 fig, 21 references

  8. Premature awakening and underuse of neuromuscular monitoring in a registry of patients with butyrylcholinesterase deficiency

    DEFF Research Database (Denmark)

    Thomsen, J L; Nielsen, C V; Palmqvist, D F

    2015-01-01

    , neuromuscular monitoring, and postoperative respiratory complications, defined as arterial oxygen desaturation prematurely awakened if anaesthesia had been terminated while the patient was still...... paralysed. RESULTS: We included 123 patients. Neuromuscular monitoring was applied before awakening in 48 (39%) patients. A nerve stimulator was never used or only after attempted awakening in the remaining 75 (61%) patients. Premature awakening occurred in 75 (100%) and 14 (29%) of the unmonitored...

  9. Monitoring of the Adult Patient on Venoarterial Extracorporeal Membrane Oxygenation

    Directory of Open Access Journals (Sweden)

    Mabel Chung

    2014-01-01

    Full Text Available Venoarterial extracorporeal membrane oxygenation (VA ECMO provides mechanical support to the patient with cardiac or cardiopulmonary failure. This paper reviews the physiology of VA ECMO including the determinants of ECMO flow and gas exchange. The efficacy of this therapy may be determined by assessing patient hemodynamics and device flow, overall gas exchange support, markers of adequate oxygen delivery, and pulsatility of the arterial blood pressure waveform.

  10. Oxygen transport in waterlogged soils, Part I. Approaches to modelling soil and crop response to oxygen deficiency

    International Nuclear Information System (INIS)

    Obando Moncayo, F.H.

    2004-01-01

    This lecture outlines in a simple way the mathematics of various cases of diffusion which have been widely used in modelling soil aeration. Simplifications of the general equation of diffusion (Fick's law) giving two possible forms of the problem: planar or one-dimensional diffusion and radial diffusion are given. Furthermore, the solution of diffusion equation is obtained by the analogy to the problem of electrical flow (Ohm's law). Taking into consideration the soil respiration process, the continuity equation which accounts for the law of conservation of mass is solved. The purpose of this paper has been to review the interrelation soil structure-air movement in waterlogged clay soils, and its consequences on plant growth and crop production. Thus, the mathematics of diffusion is presented, and then its application to specific cases of soil aeration such as diffusion in the soil profile, soil aggregates and roots is given. The following assumptions are taken into consideration. Gas flow in soils is basically diffusion-dependent. Gas-phase diffusion is the major mechanism for vertical or longitudinal transport (long distance transport); this means, with depth Z in the soil profile (macro diffusion). For horizontal transport (short distance transport or micro diffusion) which is assumed to be in X direction; in this case, the geometry of aggregates and the liquid phase are the major components of resistance for diffusion. Soil aggregates and roots are considered to be spherical and cylindrical in shape respectively. Soil oxygen consumption, Sr, is taken to be independent of the oxygen concentration and considered to proceed at the same rate until oxygen supply drops to critical levels. Thus, aeration problems are assumed to begin when at any time, in the root zone, the oxygen diffusion rate, ODR, becomes less than 30x10 -8 g.cm -2 .sec -1 , or the value of redox potential Eh is less than +525 mv

  11. Both AtrbohD and AtrbohF are essential for mediating responses to oxygen deficiency in Arabidopsis.

    Science.gov (United States)

    Liu, Bo; Sun, Lirong; Ma, Liya; Hao, Fu-Shun

    2017-06-01

    Both AtrbohD and AtrbohF promote the increases in activities of ADH, PDC, LDH, and Ca 2+ levels, and induce the expression of multiple hypoxia response genes, thus improving Arabidopsis adaptation to oxygen deficiency. NADPH oxidase AtrbohD and AtrbohF cooperatively play key roles in regulation of growth and stress signaling in Arabidopsis. However, reports on AtrbohD and AtrbohF functioning together in hypoxia signaling are scarce, and the underlying mechanisms remain elusive. Here, we show that the double null mutant atrbohD/F is more sensitive to oxygen deprivation compared with wild type (WT) and the single mutant atrbohD and atrbohF. Under oxygen deficiency, enhancements of the transcripts of alcohol dehydrogenase 1 (ADH1) and pyruvate decarboxylase 1 (PDC1) and the activities of ADH, PDC and lactate dehydrogenase in WT are clearly reduced in the single mutants, and more strongly reduced in the double mutant. Moreover, increases in the production of ATP, H 2 O 2 and Ca 2+ in WT are significantly arrested in atrbohD, atrbohF, and especially in atrbohD/F. Hypoxia-promoted rise in the expression of some hypoxic responsive genes is also inhibited in atrbohD/F relative to WT, atrbohD and atrbohF. These genes include ethylene response factor 73, lactate dehydrogenase, MYB transcription factor 2, sucrose synthase 1 (SUS1), SUS4, heat stress transcription factor A2 and heat-shock protein 18.2. These results suggest that both AtrbohD and AtrbohF are essential for mediating hypoxia signaling. H 2 O 2 derived from AtrbohD and AtrbohF triggers the Ca 2+ increase and induces the expression of multiple hypoxia response genes, thus improving Arabidopsis tolerance to low-oxygen stress. These findings provide new insights into the mechanisms of AtrbohF in regulating the responses to oxygen deprivation in Arabidopsis.

  12. Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study

    Science.gov (United States)

    Esenaliev, Rinat O.; Larina, Irina V.; Larin, Kirill V.; Deyo, Donald J.; Motamedi, Massoud; Prough, Donald S.

    2002-08-01

    Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe. We tested the system in vitro in sheep blood with experimentally varied oxygenation. Our results demonstrated that (1) the amplitude and temporal profile of the optoacoustic waves increase with blood oxygenation in the range from 24% to 92%, (2) optoacoustic signals can be detected despite optical and acoustic attenuation by thick bone, and (3) the system is capable of real-time and continuous measurements. These results suggest that the optoacoustic technique is technically feasible for continuous, noninvasive monitoring of cerebral venous oxygenation.

  13. Enhanced metabolic versatility of planktonic sulfur-oxidizing γ-proteobacteria in an oxygen-deficient coastal ecosystem

    Directory of Open Access Journals (Sweden)

    Alejandro A. Murillo

    2014-07-01

    Full Text Available Sulfur-oxidizing Gamma-proteobacteria are abundant in marine oxygen-deficient waters, and appear to play a key role in a previously unrecognized cryptic sulfur cycle. Metagenomic analyses of members of the uncultured SUP05 lineage in the Canadian seasonally anoxic fjord Saanich Inlet (SI, hydrothermal plumes in the Guaymas Basin (GB and single cell genomics analysis of two ARCTIC96BD-19 representatives from the South Atlantic Sub-Tropical Gyre (SASG have shown them to be metabolically versatile. However, SI and GB SUP05 bacteria seem to be obligate chemolithoautotrophs, whereas ARCTIC96BD-19 has the genetic potential for aerobic respiration. Here, we present results of a metagenomic analysis of sulfur-oxidizing Gamma-proteobacteria (GSO, closely related to the SUP05/ARCTIC96BD-19 clade, from a coastal ecosystem in the eastern South Pacific (ESP. This ecosystem experiences seasonal anoxia and accumulation of nitrite and ammonium at depth, with a corresponding increase in the abundance of GSO representatives. The ESP-GSOs appear to have a significantly different gene complement than those from Saanich Inlet, Guaymas Basin and SASG. Genomic analyses of de novo assembled contigs indicate the presence of a complete aerobic respiratory complex based on the cytochrome bc1 oxidase. Furthermore, they appear to encode a complete TCA cycle and several transporters for dissolved organic carbon species, suggesting a mixotrophic lifestyle. Thus, the success of sulfur-oxidizing Gamma-proteobacteria in oxygen-deficient marine ecosystems appears due not only to their previously recognized anaerobic metabolic versatility, but also to their capacity to function under aerobic conditions using different carbon sources. Finally, members of ESP-GSO cluster also have the genetic potential for reducing nitrate to ammonium based on the nirBD genes, and may therefore facilitate a tighter coupling of the nitrogen and sulfur cycles in oxygen-deficient waters.

  14. Monitor hemoglobin concentration and oxygen saturation in living mouse tail using photoacoustic CT scanner

    Science.gov (United States)

    Liu, Bo; Kruger, Robert; Reinecke, Daniel; Stantz, Keith M.

    2010-02-01

    Purpose: The purpose of this study is to use PCT spectroscopy scanner to monitor the hemoglobin concentration and oxygen saturation change of living mouse by imaging the artery and veins in a mouse tail. Materials and Methods: One mouse tail was scanned using the PCT small animal scanner at the isosbestic wavelength (796nm) to obtain its hemoglobin concentration. Immediately after the scan, the mouse was euthanized and its blood was extracted from the heart. The true hemoglobin concentration was measured using a co-oximeter. Reconstruction correction algorithm to compensate the acoustic signal loss due to the existence of bone structure in the mouse tail was developed. After the correction, the hemoglobin concentration was calculated from the PCT images and compared with co-oximeter result. Next, one mouse were immobilized in the PCT scanner. Gas with different concentrations of oxygen was given to mouse to change the oxygen saturation. PCT tail vessel spectroscopy scans were performed 15 minutes after the introduction of gas. The oxygen saturation values were then calculated to monitor the oxygen saturation change of mouse. Results: The systematic error for hemoglobin concentration measurement was less than 5% based on preliminary analysis. Same correction technique was used for oxygen saturation calculation. After correction, the oxygen saturation level change matches the oxygen volume ratio change of the introduced gas. Conclusion: This living mouse tail experiment has shown that NIR PCT-spectroscopy can be used to monitor the oxygen saturation status in living small animals.

  15. Monitoring of blood oxygenation in brain by resonance Raman spectroscopy

    DEFF Research Database (Denmark)

    Brazhe, Nadezda A; Thomsen, Kirsten; Lønstrup, Micael

    2018-01-01

    Blood oxygenation in cerebral vessels is an essential parameter to evaluate brain function and to investigate the coupling between local blood flow and neuronal activity. We apply resonance Raman spectroscopy in vivo to study hemoglobin oxygenation in cortex vessels of anesthetized ventilated mice....... We demonstrate that the pairs of Raman peaks at 1355 and1375 cm-1(symmetric vibrations of pyrrol half-rings in the heme molecule), 1552 and 1585 cm-1and 1602 and 1638 cm-1(vibrations of methine bridges in heme molecule) are reliable markers for quantitative estimation of the relative amount...

  16. Reliable monitoring of oxygen saturation via pulse oximetry: Which ...

    African Journals Online (AJOL)

    This study focuses on identifying the best site for placement of pulse oximeter probe accurate measuring of oxygen saturation. Twenty-three healthy male volunteers aged 20 to 40 years old were recruited in this study. Cold pressor test was done to stim 460 measurements of SpO2level were obtained throughout the study.

  17. BMI-1 Mediates Estrogen-Deficiency-Induced Bone Loss by Inhibiting Reactive Oxygen Species Accumulation and T Cell Activation.

    Science.gov (United States)

    Li, Jinbo; Wang, Qian; Yang, Renlei; Zhang, Jiaqi; Li, Xing; Zhou, Xichao; Miao, Dengshun

    2017-05-01

    Previous studies have shown that estrogen regulates bone homeostasis through regulatory effects on oxidative stress. However, it is unclear how estrogen deficiency triggers reactive oxygen species (ROS) accumulation. Recent studies provide evidence that the B lymphoma Mo-MLV insertion region 1 (BMI-1) plays a critical role in protection against oxidative stress and that this gene is directly regulated by estrogen via estrogen receptor (ER) at the transcriptional level. In this study, ovariectomized mice were given drinking water with/without antioxidant N-acetyl-cysteine (NAC, 1 mg/mL) supplementation, and compared with each other and with sham mice. Results showed that ovariectomy resulted in bone loss with increased osteoclast surface, increased ROS levels, T cell activation, and increased TNF and RANKL levels in serum and in CD4 T cells; NAC supplementation largely prevented these alterations. BMI-1 expression levels were dramatically downregulated in CD4 T cells from ovariectomized mice. We supplemented drinking water to BMI-1-deficient mice with/without NAC and compared them with each other and with wild-type (WT) mice. We found that BMI-1 deficiency mimicked alterations observed in ovariectomy whereas NAC supplementation reversed all alterations induced by BMI-1 deficiency. Because T cells are critical in mediating ovariectomy-induced bone loss, we further assessed whether BMI-1 overexpression in lymphocytes can protect against estrogen deficiency-induced osteoclastogenesis and bone loss by inhibiting oxidative stress, T cell activation, and RANKL production. When WT and Eμ-BMI-1 transgenic mice with BMI-1 specifically overexpressed in lymphocytes were ovariectomized and compared with each other and with WT sham mice, we found that BMI-1 overexpression in lymphocytes clearly reversed all alterations induced by ovariectomy. Results from this study indicate that estrogen deficiency downregulates BMI-1 and subsequently increases ROS, T cell activation, and

  18. Some aspects of the oxygen-deficient conditions and denitrification in the Arabian Sea

    Digital Repository Service at National Institute of Oceanography (India)

    Naqvi, S.W.A.

    Utilizing a fairly large amount of recently collected data, some outstanding questions concerning the Arabian Sea denitrification problem are addressed. The true level of dissolved oxygen, determined colorimetrically, are about an order of magnitude...

  19. Dissolved oxygen mapping: A powerful tool for site assessments and ground water monitoring

    International Nuclear Information System (INIS)

    Newman, W.A.; Kimball, G.

    1992-01-01

    Dissolved oxygen concentration profiles often provide an excellent indication of the natural biological activity of microorganisms in ground water. The analysis of dissolved oxygen in ground water also provides a rapid, inexpensive method for determining the areal extent of contaminant plumes containing aerobically degraded compounds such as petroleum hydrocarbons. Indigenous hydrocarbon degrading organisms are present at most petroleum product spills giving this technique an almost universal application for dissolved hydrocarbons in ground water. Data from several sites will be presented to demonstrate the relationship between oxygen and dissolved contaminant concentrations. The inverse relationship between oxygen concentrations and dissolved contaminants can be used in many ways. During the initial site assessment, rapid on-site testing of ground water can provide real time data to direct drilling by identification of potentially contaminated locations. Several analytical techniques are available that allow field analysis to be performed in less than five minutes. Dissolved oxygen testing also provides an inexpensive way to monitor hydrocarbon migration without expensive gas chromatography. Often a plume of oxygen depleted ground water extends farther downgradient than the dissolved hydrocarbon plume. The depletion of oxygen in a well can provide an early warning system that detects upgradient contamination before the well is impacted by detectable levels of contaminants. Another application is the measurement of the natural degradation potential for aerobic remediation. If an aerobic in-situ remediation is used, dissolved oxygen monitoring provides an inexpensive method to monitor the progress of the remediation

  20. The spatial distribution of temperature and oxygen deficiency in spark-plasma sintered superconducting Bi-based materials

    International Nuclear Information System (INIS)

    Govea-Alcaide, E.; Pérez-Fernández, J.E.; Machado, I.F.; Jardim, R.F.

    2014-01-01

    Pre-reacted powders of (Bi–Pb) 2 Sr 2 Ca 2 Cu 3 O 10+δ (Bi-2223) were consolidated by using the spark plasma sintering (SPS) technique under vacuum and at different consolidate temperatures T D . X-ray diffraction patterns revealed that the dominant phase in all SPS samples is the Bi-2223 phase, but traces of the Bi 2 Sr 2 CaCu 2 O 10+x (Bi-2212) phase were identified. We have found that the transport properties of SPS samples depend on their oxygen content because the SPS process is performed under vacuum. Simulations by using the finite element method (FEM) were performed for determining the actual temperature in which powders are consolidated. From these results we have inferred that SPS samples are oxygen deficient and such a deficiency is more marked near the grain boundaries, suggesting the occurrence of grains with core–shell morphology. We also argued that the width of the shell depends on the consolidation temperature, a feature corroborated by the FEM simulations

  1. Direct tissue oxygen monitoring by in vivo photoacoustic lifetime imaging (PALI)

    Science.gov (United States)

    Shao, Qi; Morgounova, Ekaterina; Ashkenazi, Shai

    2014-03-01

    Tissue oxygen plays a critical role in maintaining tissue viability and in various diseases, including response to therapy. Images of oxygen distribution provide the history of tissue hypoxia and evidence of oxygen availability in the circulatory system. Currently available methods of direct measuring or imaging tissue oxygen all have significant limitations. Previously, we have reported a non-invasive in vivo imaging modality based on photoacoustic lifetime. The technique maps the excited triplet state of oxygen-sensitive dye, thus reflects the spatial and temporal distribution of tissue oxygen. We have applied PALI on tumor hypoxia in small animals, and the hypoxic region imaged by PALI is consistent with the site of the tumor imaged by ultrasound. Here, we present two studies of applying PALI to monitor changes of tissue oxygen by modulations. The first study involves an acute ischemia model using a thin thread tied around the hind limb of a normal mouse to reduce the blood flow. PALI images were acquired before, during, and after the restriction. The drop of muscle pO2 and recovery from hypoxia due to reperfusion were observed by PALI tracking the same region. The second study modulates tissue oxygen by controlling the percentage of oxygen the mouse inhales. We demonstrate that PALI is able to reflect the change of oxygen level with respect to both hyperbaric and hypobaric conditions. We expect this technique to be very attractive for a range of clinical applications in which tissue oxygen mapping would improve therapy decision making and treatment planning.

  2. An electrochemical sensor for monitoring oxygen or hydrogen in water

    International Nuclear Information System (INIS)

    Leitai Yang; Morris, D.R.; Lister, D.H.

    1997-01-01

    Preliminary studies have been done on a simple electrochemical sensor which shows promise as a cheap, robust instrument for measuring dissolved oxygen or hydrogen in water. The sensor is based upon the solid-state electrolyte ''Nafion'' (trade name of perfluorinated sulphonic acid, manufactured by DuPont Inc.). The Nafion was dissolved in a mixture of aliphatic alcohols, made into a slurry with platinum black, and applied to a ∼1 cm-square electrode made of stainless steel gauze. The potential of the electrode was measured relative to a standard calomel electrode (SCE) in acid solutions at room temperature through which mixtures of oxygen and nitrogen or hydrogen and nitrogen were bubbled. The sensor was responsive to the equilibrating gas with good reproducibility. A similar sensor without the Nafion was not at all sensitive to changes in oxygen concentration. The voltage response of the sensor showed non-Nernstian behaviour, which suggests that the electrochemical reactions at the electrode surface are complex. Further testing of the sensor is required to verify its sensitivity and responsiveness in typical reactor coolant chemistries and to demonstrate its durability over a range of temperatures. (author). 4 refs, 4 figs, 1 tab

  3. An electrochemical sensor for monitoring oxygen or hydrogen in water

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Leitai; Morris, D R; Lister, D H [University of New Brunswick, Fredericton (Canada). Dept. of Chemical Engineering

    1997-02-01

    Preliminary studies have been done on a simple electrochemical sensor which shows promise as a cheap, robust instrument for measuring dissolved oxygen or hydrogen in water. The sensor is based upon the solid-state electrolyte ``Nafion`` (trade name of perfluorinated sulphonic acid, manufactured by DuPont Inc.). The Nafion was dissolved in a mixture of aliphatic alcohols, made into a slurry with platinum black, and applied to a {approx}1 cm-square electrode made of stainless steel gauze. The potential of the electrode was measured relative to a standard calomel electrode (SCE) in acid solutions at room temperature through which mixtures of oxygen and nitrogen or hydrogen and nitrogen were bubbled. The sensor was responsive to the equilibrating gas with good reproducibility. A similar sensor without the Nafion was not at all sensitive to changes in oxygen concentration. The voltage response of the sensor showed non-Nernstian behaviour, which suggests that the electrochemical reactions at the electrode surface are complex. Further testing of the sensor is required to verify its sensitivity and responsiveness in typical reactor coolant chemistries and to demonstrate its durability over a range of temperatures. (author). 4 refs, 4 figs, 1 tab.

  4. Thermal expansion behaviour in the oxygen deficient perovskites Sr2BSbO5.5 (B=Ca, Sr, Ba). Competing effects of water and oxygen ordering

    International Nuclear Information System (INIS)

    Zhou Qingdi; Kennedy, Brendan J.; Avdeev, Maxim

    2011-01-01

    Neutron diffractions studies reveal the presence of oxygen disorder in the oxygen deficient perovskites Sr 2 BSbO 5.5 (B=Ca, Sr, Ba). Synchrotron X-ray studies demonstrate that these oxides have a double perovskite-type structure with the cell size increasing as the size of the B cation increases from 8.2114(2) A for B=Ca to 8.4408(1) A for B=Ba. It is postulated that a combination of local clustering of the anions and vacancies together with water-water and water-host hydrogen bonds plays a role in defining the volume of the encapsulated water clusters and that changes in the local structure upon heating result in anomalous thermal expansion observed in variable temperature diffraction measurements. - Graphical abstract: The oxides Sr 2 BSbO 5.5 (B=Ca, Sr, Ba) have unusual anion disorder. There is a lag in the contraction in the cell size of Sr 2 CaSbO 5.5 nH 2 O established from X-ray diffraction measurements following the loss of water suggesting changes on the local structure are important. Highlights: → The average structures of the defect perovskites Sr 2 MSbO 5.5 established. → Anion and cation disorder quantified by neutron and synchrotron X-ray diffraction. → Anomalous thermal expansion due to local clustering of anions and vacancies observed.

  5. μSR in oxygen deficient YBa2Cu3Ox (6.5≤x≤7.0)

    International Nuclear Information System (INIS)

    Puempin, B.; Keller, H.; Kuendig, W.; Savic, I.M.; Schneider, J.W.; Simmler, H.; Zimmermann, P.; Kaldis, E.; Rusiecki, S.; Rossel, C.

    1991-01-01

    A systematic μSR study of the local magnetic field distribution in a series of oxygen deficient YBa 2 Cu 3 O x samples with 6.5≤x≤7.0 is reported. Special attention was given to perform the experiments under the same conditions, so that the oxygen content of the measured samples was the only parameter varied. The behavior of the depolarization rate σ as a function of the oxygen content x was found to have strong similarities with the behavior of the critical temperature Tc as a function of x. In particular, two step-like increases of σ were observed above x=6.7 and 6.9. The temperature dependence of the normalized depolarization rate σ(T)/σ(0) is well described by the two-fluid model for x≥6.781(1) and clearly deviates from this behavior for x≤6.704(1). Our results are compared to those obtained by other groups. (orig.)

  6. Ordered oxygen deficient '112' perovskites, LnBaCo2 : complex ...

    Indian Academy of Sciences (India)

    Administrator

    are labeled on the graph. .... in agreement with Kanamori Goodenough rules. In sum- mary, these results ... exhibit very rich phase diagrams as illustrated in figure 9. The latter .... which make that the control of oxygen content in these phases is ...

  7. The MOST - Monitor for Oxygenation of Surface and Tissue.

    Science.gov (United States)

    1995-10-01

    anesthesia Effectiveness of COR Bio-feedback for peripheral vasodilation Relationship of CPAP and PEEP to atelectasis Waveforms Diagnosis of irregularities...deliberate hypoxia in premature infants Servo-controlled saturation, prematures Converse 02 in home 02 therapy Determine optimal PEEP and CPAP Monitor...Kusakawa I, Ohata J, Kawano T, Honma Y. Use of Pulse Oximetry In Neonatal Anesthe- sia. J Perinatology. 1987:7;343-5. Nishimura S, Tomita Y, Horiuchi T

  8. Enhanced thermoelectric property of oxygen deficient nickel doped SnO2 for high temperature application

    Science.gov (United States)

    Paulson, Anju; Sabeer, N. A. Muhammad; Pradyumnan, P. P.

    2018-04-01

    Motivated by the detailed investigation on the thermoelectric performance of oxide materials our work concentrated on the influence of acceptor dopants and defect density in the lattice plane for the enhancement of thermoelectric power. The series of Sn1‑x Nix O2 (0.01 ≤ x ≤ 0.05) compositions were prepared by solid state reaction mechanism and found that 3 atomic percentage Ni doped SnO2 can be considered as a good candidate due to its promising electrical and transport properties. Defect lattices were introduced in the sample and the deviation from oxygen stochiometry was ensured using photoluminescence measurement. High power factor was obtained for the 3 atomic percentage nickel doped SnO2 due to the effective number of charge carrier concentration and the depletion of oxygen rich layers. Defect centered and acceptor doped SnO2 lattice opens a new door for energy harvesting at higher temperatures.

  9. Upper-critical fields of YBa2Cu3O7-δ epitaxial thin films with variable oxygen deficiency δ

    International Nuclear Information System (INIS)

    Jones, E.C.; Christen, D.K.; Thompson, J.R.; Ossandon, J.G.; Feenstra, R.; Phillips, J.M.; Siegal, M.P.

    1994-01-01

    Fluctuation analysis in the limit of high magnetic fields was performed on three epitaxial thin films of YBa 2 Cu 3 O 7-δ for various oxygen deficiencies δ c2 (T) slope of -1.7 T/K for H parallel c, consistent with previous observations of transport and magnetic properties. Moreover, the 3D scaling showed better convergence than the 2D scaling, which gave relatively low values of H c2 . In contrast, the transitions were not adequately described by either scaling for T c off the 90-K plateau; it is speculated that this is due to an extrinsic broadening of the transitions, possibly due to the lack of a complete percolation path of the ortho-I phase (δ=0)

  10. Magnetic studies of current conduction and flux pinning in high-Tc cuprates: Virgin, irradiated, and oxygen deficient materials

    International Nuclear Information System (INIS)

    Thompson, J.R.; Civale, L.; Marwick, A.D.; Holtzberg, F.

    1992-09-01

    To increase the current density and pinning of magnetic flux in high temperature superconductors, defects with point-like and line-like geometries were created in controlled numbers using ion irradiation methods. Single crystals of Y 1 Ba 2 Cu 3 O 7 and Bi 2 Sr 2 Ca 1 Cu 2 0 8 superconductors were studied using dc magnetic methods. These studies showed greatly increased irreversibility in the vortex state magnetization and enhanced intragrain current density J c following irradiation. Linear defects, created by irradiation with energetic heavy ions, are particularly effective in pinning vortices at higher temperatures and magnetic fields. Further investigations of ''flux creep'' (the time dependence of magnetization) are well described by recent vortex glass and collective pinning theories. Complementary investigations have delineated the role of oxygen deficiency δ on pinning in aligned Y 1 Ba 2 Cu 3 O 7-δ materials

  11. A close correlation between induced ferromagnetism and oxygen deficiency in Fe doped In2O3

    International Nuclear Information System (INIS)

    Singhal, R.K.; Samariya, A.; Kumar, Sudhish; Sharma, S.C.; Xing, Y.T.; Deshpande, U.P.; Shripathi, T.; Saitovitch, E.

    2010-01-01

    We report on the reversible manipulation of room temperature ferromagnetism in Fe (5%) doped In 2 O 3 polycrystalline magnetic semiconductor. The X-ray diffraction and photoemission measurements confirm that the Fe ions are well incorporated into the lattice, substituting the In 3+ ions. The magnetization measurements show that the host In 2 O 3 has a diamagnetic ground state, while it shows weak ferromagnetism at 300 K upon Fe doping. The as-prepared sample was then sequentially annealed in hydrogen, air, vacuum and finally in air. The ferromagnetic signal shoots up by hydrogenation as well as vacuum annealing and bounces back upon re-annealing the samples in air. The sequence of ferromagnetism shows a close inter-relationship with the behavior of oxygen vacancies (V o ). The Fe ions tend to a transform from 3+ to 2+ state during the giant ferromagnetic induction, as revealed by photoemission spectroscopy. A careful characterization of the structure, purity, magnetic, and transport properties confirms that the ferromagnetism is due to neither impurities nor clusters but directly related to the oxygen vacancies. The ferromagnetism can be reversibly controlled by these vacancies while a parallel variation of carrier concentration, as revealed by resistance measurements, appears to be a side effect of the oxygen vacancy variation.

  12. Cutaneous respirometry by dynamic measurement of mitochondrial oxygen tension for monitoring mitochondrial function in vivo.

    Science.gov (United States)

    Harms, Floor A; Voorbeijtel, Wilhelmina J; Bodmer, Sander I A; Raat, Nicolaas J H; Mik, Egbert G

    2013-09-01

    Progress in diagnosis and treatment of mitochondrial dysfunction in chronic and acute disease could greatly benefit from techniques for monitoring of mitochondrial function in vivo. In this study we demonstrate the feasibility of in vivo respirometry in skin. Mitochondrial oxygen measurements by means of oxygen-dependent delayed fluorescence of protoporphyrin IX are shown to provide a robust basis for measurement of local oxygen disappearance rate (ODR). The fundamental principles behind the technology are described, together with an analysis method for retrievel of respirometry data. The feasibility and reproducibility of this clinically useful approach are demonstrated in a series of rats. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Method and apparatus for monitoring oxygen partial pressure in air masks

    Science.gov (United States)

    Kelly, Mark E. (Inventor); Pettit, Donald R. (Inventor)

    2006-01-01

    Method and apparatus are disclosed for monitoring an oxygen partial pressure in an air mask and providing a tactile warning to the user. The oxygen partial pressure in the air mask is detected using an electrochemical sensor, the output signal from which is provided to a comparator. The comparator compares the output signal with a preset reference value or range of values representing acceptable oxygen partial pressures. If the output signal is different than the reference value or outside the range of values, the air mask is vibrated by a vibrating motor to alert the user to a potentially hypoxic condition.

  14. The monitoring of oxygen, hydrogen and carbon in the sodium circuits of the PFR

    International Nuclear Information System (INIS)

    Mason, L.; Morrison, N.S.; Robertson, C.M.; Trevillion, E.A.

    1984-01-01

    The paper reviews the instrumentation available for monitoring oxygen, hydrogen, tritium and carbon impurity levels on the primary and secondary circuits of PFR. Circuit oxygen levels measured using electrochemical oxygen meters are compared to estimates from circuit plugging meters. The data are interpreted in the light of information from cold trap temperatures. Measurements of secondary circuit hydrogen levels using both the sodium and gas phase hydrogen detection equipment are compared to estimates of circuit hydrogen levels from plugging meters and variations in sodium phase hydrogen levels during power operation are discussed. (author)

  15. Brain Tissue Oxygen: In Vivo Monitoring with Carbon Paste Electrodes

    Directory of Open Access Journals (Sweden)

    John P. Lowry

    2005-11-01

    Full Text Available In this communication we review selected experiments involving the use ofcarbon paste electrodes (CPEs to monitor and measure brain tissue O2 levels in awakefreely-moving animals. Simultaneous measurements of rCBF were performed using the H2clearance technique. Voltammetric techniques used include both differential pulse (O2 andconstant potential amperometry (rCBF. Mild hypoxia and hyperoxia produced rapidchanges (decrease and increase respectively in the in vivo O2 signal. Neuronal activation(tail pinch and stimulated grooming produced similar increases in both O2 and rCBFindicating that CPE O2 currents provide an index of increases in rCBF when such increasesexceed O2 utilization. Saline injection produced a transient increase in the O2 signal whilechloral hydrate produced slower more long-lasting changes that accompanied the behavioralchanges associated with anaesthesia. Acetazolamide increased O2 levels through an increasein rCBF.

  16. Magnetization and flux pinning in high-Tc cuprates: Irradiated and oxygen deficient materials

    International Nuclear Information System (INIS)

    Thompson, J.R.; Civale, L.; Marwick, A.D.; Holtzberg, F.

    1992-11-01

    This work surveys recent studies of the intragrain current density J and vortex pinning in high Tc superconductors. Materials include Y 1 Ba 2 Cu 3 O 7-δ and Bi 2 Sr 2 Ca 1 Cu 2 O 8 single crystals and aligned polycrystals. To probe the flux pinning, we modified the strength, number, and morphology of defects. Varying the oxygen content (7-δ) in YBa 2 Cu 3 O 7-δ or irradiating the materials with ions, having either light or heavy masses, gives systematic changes in the character of the all-important defects

  17. Optoacoustic monitoring of central and peripheral venous oxygenation during simulated hemorrhage

    Science.gov (United States)

    Petrov, Andrey; Kinsky, Michael; Prough, Donald S.; Petrov, Yuriy; Petrov, Irene Y.; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Khan, Muzna N.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock may be fatal unless promptly recognized and treated. The most commonly used indicators of shock (hypotension and tachycardia) lack sensitivity and specificity. In the initial stages of shock, the body compensates by reducing blood flow to the peripheral (skin, muscle, etc.) circulation in order to preserve vital organ (brain, heart, liver) perfusion. Characteristically, this can be observed by a greater reduction in peripheral venous oxygenation (for instance, the axillary vein) compared to central venous oxygenation (the internal jugular vein). While invasive measurements of oxygenation are accurate, they lack practicality and are not without complications. We have developed a novel optoacoustic system that noninvasively determines oxygenation in specific veins. In order to test this application, we used lower body negative pressure (LBNP) system, which simulates hemorrhage by exerting a variable amount of suction on the lower body, thereby reducing the volume of blood available for central circulation. Restoration of normal blood flow occurs promptly upon cessation of LBNP. Using two optoacoustic probes, guided by ultrasound imaging, we simultaneously monitored oxygenation in the axillary and internal jugular veins (IJV). LBNP began at -20 mmHg, thereafter was reduced in a step-wise fashion (up to 30 min). The optoacoustically measured axillary oxygenation decreased with LBNP, whereas IJV oxygenation remained relatively constant. These results indicate that our optoacoustic system may provide safe and rapid measurement of peripheral and central venous oxygenation and diagnosis of shock with high specificity and sensitivity.

  18. p53-competent cells and p53-deficient cells display different susceptibility to oxygen functionalized graphene cytotoxicity and genotoxicity.

    Science.gov (United States)

    Petibone, Dayton M; Mustafa, Thikra; Bourdo, Shawn E; Lafont, Andersen; Ding, Wei; Karmakar, Alokita; Nima, Zeid A; Watanabe, Fumiya; Casciano, Daniel; Morris, Suzanne M; Dobrovolsky, Vasily N; Biris, Alexandru S

    2017-11-01

    Due to the distinctive physical, electrical, and chemical properties of graphene nanomaterials, numerous efforts pursuing graphene-based biomedical and industrial applications are underway. Oxidation of pristine graphene surfaces mitigates its otherwise hydrophobic characteristic thereby improving its biocompatibility and functionality. Yet, the potential widespread use of oxidized graphene derivatives raises concern about adverse impacts on human health. The p53 tumor suppressor protein maintains cellular and genetic stability after toxic exposures. Here, we show that p53 functional status correlates with oxygen functionalized graphene (f-G) cytotoxicity and genotoxicity in vitro. The f-G exposed p53-competent cells, but not p53-deficient cells, initiated G 0 /G 1 phase cell cycle arrest, suppressed reactive oxygen species, and entered apoptosis. There was p53-dependent f-G genotoxicity evident as increased structural chromosome damage, but not increased gene mutation or chromatin loss. In conclusion, the cytotoxic and genotoxic potential for f-G in exposed cells was dependent on the p53 functional status. These findings have broad implications for the safe and effective implementation of oxidized graphene derivatives into biomedical and industrial applications. Published 2017. This article has been contributed to by US Government employees and their work is in the public domain in the USA. Published 2017. This article has been contributed to by US Government employees and their work is in the public domain in the USA.

  19. Stoichiometric and Oxygen-Deficient VO2 as Versatile Hole Injection Electrode for Organic Semiconductors.

    Science.gov (United States)

    Fu, Keke; Wang, Rongbin; Katase, Takayoshi; Ohta, Hiromichi; Koch, Norbert; Duhm, Steffen

    2018-03-28

    Using photoemission spectroscopy, we show that the surface electronic structure of VO 2 is determined by the temperature-dependent metal-insulator phase transition and the density of oxygen vacancies, which depends on the temperature and ultrahigh vacuum (UHV) conditions. The atomically clean and stoichiometric VO 2 surface is insulating at room temperature and features an ultrahigh work function of up to 6.7 eV. Heating in UHV just above the phase transition temperature induces the expected metallic phase, which goes in hand with the formation of oxygen defects (up to 6% in this study), but a high work function >6 eV is maintained. To demonstrate the suitability of VO 2 as hole injection contact for organic semiconductors, we investigated the energy-level alignment with the prototypical organic hole transport material N, N'-di(1-naphthyl)- N, N'-diphenyl-(1,1'-biphenyl)-4,4'-diamine (NPB). Evidence for strong Fermi-level pinning and the associated energy-level bending in NPB is found, rendering an Ohmic contact for holes.

  20. Conditions for oxygen-deficient combustion during accidents with severe core concrete thermal attack

    International Nuclear Information System (INIS)

    Luangdilok, W.; Elicson, G.T.; Berger, W.E. Jr.

    1993-01-01

    This paper addresses the interactions between MCCI (molten core-concrete interactions)-induced offgas releases, mostly the combustible gases, natural circulation between the cavity and the lower containment based on recent research developments in the area of mixed convection flow (Epstein, et al., 1989; Epstein, 1988; Epstein, 1992) between compartments, and their effects on combustion in PWR containments during prolonged severe accidents. Specifically, large dry PWR containments undergoing severe core-concrete attack during station blackouts where the containment atmosphere is expected to be inerted are objects of this analysis. The purpose of this paper, given the conditions that oxygen can be brought to the cavity, is to demonstrate that consumption of most oxygen present in the containment can be achieved in a reasonable time scale assuming that combustion is not subject to flammability limits due to the high cavity temperatures. The conditions for cavity combustion depend on several factors including good gas flowpaths between the cavity and other containment regions, and combustion processes within the cavity with the hot debris acting as the ignition source

  1. Pericellular oxygen monitoring with integrated sensor chips for reproducible cell culture experiments.

    Science.gov (United States)

    Kieninger, J; Aravindalochanan, K; Sandvik, J A; Pettersen, E O; Urban, G A

    2014-04-01

    Here we present an application, in two tumour cell lines, based on the Sensing Cell Culture Flask system as a cell culture monitoring tool for pericellular oxygen sensing. T-47D (human breast cancer) and T98G (human brain cancer) cells were cultured either in atmospheric air or in a glove-box set at 4% oxygen, in both cases with 5% CO2 in the gas phase. Pericellular oxygen tension was measured with the help of an integrated sensor chip comprising oxygen sensor arrays. Obtained results illustrate variation of pericellular oxygen tension in attached cells covered by stagnant medium. Independent of incubation conditions, low pericellular oxygen concentration levels, usually associated with hypoxia, were found in dense cell cultures. Respiration alone brought pericellular oxygen concentration down to levels which could activate hypoxia-sensing regulatory processes in cultures believed to be aerobic. Cells in culture believed to experience conditions of mild hypoxia may, in reality, experience severe hypoxia. This would lead to incorrect assumptions and suggests that pericellular oxygen concentration readings are of great importance to obtain reproducible results when dealing with hypoxic and normoxic (aerobic) incubation conditions. The Sensing Cell Culture Flask system allows continuous monitoring of pericellular oxygen concentration with outstanding long-term stability and no need for recalibration during cell culture experiments. The sensor is integrated into the flask bottom, thus in direct contact with attached cells. No additional equipment needs to be inserted into the flask during culturing. Transparency of the electrochemical sensor chip allows optical inspection of cells attached on top of the sensor. © 2014 John Wiley & Sons Ltd.

  2. Selective oxidation of n-butane to maleic anhydride under oxygen-deficient conditions over V-P-O mixed oxides

    NARCIS (Netherlands)

    Bosch, H.; Bruggink, A.A.; Ross, J.R.H.

    1987-01-01

    The selective oxidation of n-butane to maleic anhydride over V-P-O mixed oxides was studied under oxygen deficient conditions. The mixed oxides were prepared with P/V atomic ratios ranging from 0.7 to 1.0. Catalysts with P/V <1.0 did not show any selectivity to maleic anhydride formation, regardless

  3. Electrical conductivity in oxygen-deficient phases of tantalum pentoxide from first-principles calculations

    International Nuclear Information System (INIS)

    Bondi, Robert J.; Desjarlais, Michael P.; Thompson, Aidan P.; Brennecka, Geoff L.; Marinella, Matthew J.

    2013-01-01

    We apply first-principles density-functional theory (DFT) calculations, ab-initio molecular dynamics, and the Kubo-Greenwood formula to predict electrical conductivity in Ta 2 O x (0 ≤ x ≤ 5) as a function of composition, phase, and temperature, where additional focus is given to various oxidation states of the O monovacancy (V O n ; n = 0,1+,2+). In the crystalline phase, our DFT calculations suggest that V O 0 prefers equatorial O sites, while V O 1+ and V O 2+ are energetically preferred in the O cap sites of TaO 7 polyhedra. Our calculations of DC conductivity at 300 K agree well with experimental measurements taken on Ta 2 O x thin films (0.18 ≤ x ≤ 4.72) and bulk Ta 2 O 5 powder-sintered pellets, although simulation accuracy can be improved for the most insulating, stoichiometric compositions. Our conductivity calculations and further interrogation of the O-deficient Ta 2 O 5 electronic structure provide further theoretical basis to substantiate V O 0 as a donor dopant in Ta 2 O 5 . Furthermore, this dopant-like behavior is specific to the neutral case and not observed in either the 1+ or 2+ oxidation states, which suggests that reduction and oxidation reactions may effectively act as donor activation and deactivation mechanisms, respectively, for V O n in Ta 2 O 5

  4. Near infrared spectroscopy (NIRS) to monitor tissue haemoglobin (and myoglobin) oxygenation

    NARCIS (Netherlands)

    Scheeren, T. W. L.

    2010-01-01

    Introduction: Tissue oxygenation may be monitored noninvasively by near infrared spectroscopy (NIRS) both on the thenar eminescence (muscle) and on the forehead (brain). Thenar measurement have been used to guide therapy in trauma patients ( 1 ) and to determine the prognosis of septic patients ( 2

  5. Non-invasive monitoring of tissue oxygenation during laparoscopic donor nephrectomy

    Directory of Open Access Journals (Sweden)

    Kirk Allan D

    2008-04-01

    Full Text Available Abstract Background Standard methods for assessment of organ viability during surgery are typically limited to visual cues and tactile feedback in open surgery. However, during laparoscopic surgery, these processes are impaired. This is of particular relevance during laparoscopic renal donation, where the condition of the kidney must be optimized despite considerable manipulation. However, there is no in vivo methodology to monitor renal parenchymal oxygenation during laparoscopic surgery. Methods We have developed a method for the real time, in vivo, whole organ assessment of tissue oxygenation during laparoscopic nephrectomy to convey meaningful biological data to the surgeon during laparoscopic surgery. We apply the 3-CCD (charge coupled device camera to monitor qualitatively renal parenchymal oxygenation with potential real-time video capability. Results We have validated this methodology in a porcine model across a range of hypoxic conditions, and have then applied the method during clinical laparoscopic donor nephrectomies during clinically relevant pneumoperitoneum. 3-CCD image enhancement produces mean region of interest (ROI intensity values that can be directly correlated with blood oxygen saturation measurements (R2 > 0.96. The calculated mean ROI intensity values obtained at the beginning of the laparoscopic nephrectomy do not differ significantly from mean ROI intensity values calculated immediately before kidney removal (p > 0.05. Conclusion Here, using the 3-CCD camera, we qualitatively monitor tissue oxygenation. This means of assessing intraoperative tissue oxygenation may be a useful method to avoid unintended ischemic injury during laparoscopic surgery. Preliminary results indicate that no significant changes in renal oxygenation occur as a result of pneumoperitoneum.

  6. Electrical conductivity in oxygen-deficient phases of tantalum pentoxide from first-principles calculations

    Energy Technology Data Exchange (ETDEWEB)

    Bondi, Robert J., E-mail: rjbondi@sandia.gov; Desjarlais, Michael P.; Thompson, Aidan P.; Brennecka, Geoff L.; Marinella, Matthew J. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States)

    2013-11-28

    We apply first-principles density-functional theory (DFT) calculations, ab-initio molecular dynamics, and the Kubo-Greenwood formula to predict electrical conductivity in Ta{sub 2}O{sub x} (0 ≤ x ≤ 5) as a function of composition, phase, and temperature, where additional focus is given to various oxidation states of the O monovacancy (V{sub O}{sup n}; n = 0,1+,2+). In the crystalline phase, our DFT calculations suggest that V{sub O}{sup 0} prefers equatorial O sites, while V{sub O}{sup 1+} and V{sub O}{sup 2+} are energetically preferred in the O cap sites of TaO{sub 7} polyhedra. Our calculations of DC conductivity at 300 K agree well with experimental measurements taken on Ta{sub 2}O{sub x} thin films (0.18 ≤ x ≤ 4.72) and bulk Ta{sub 2}O{sub 5} powder-sintered pellets, although simulation accuracy can be improved for the most insulating, stoichiometric compositions. Our conductivity calculations and further interrogation of the O-deficient Ta{sub 2}O{sub 5} electronic structure provide further theoretical basis to substantiate V{sub O}{sup 0} as a donor dopant in Ta{sub 2}O{sub 5}. Furthermore, this dopant-like behavior is specific to the neutral case and not observed in either the 1+ or 2+ oxidation states, which suggests that reduction and oxidation reactions may effectively act as donor activation and deactivation mechanisms, respectively, for V{sub O}{sup n} in Ta{sub 2}O{sub 5}.

  7. Colossal positive magnetoresistance in surface-passivated oxygen-deficient strontium titanite

    KAUST Repository

    David, Adrian

    2015-05-15

    Modulation of resistance by an external magnetic field, i.e. magnetoresistance effect, has been a long-lived theme of research due to both fundamental science and device applications. Here we report colossal positive magnetoresistance (CPMR) (>30,000% at a temperature of 2 K and a magnetic field of 9 T) discovered in degenerate semiconducting strontium titanite (SrTiO3) single crystals capped with ultrathin SrTiO3/LaAlO3 bilayers. The low-pressure high-temperature homoepitaxial growth of several unit cells of SrTiO3 introduces oxygen vacancies and high-mobility carriers in the bulk SrTiO3, and the three-unit-cell LaAlO3 capping layer passivates the surface and improves carrier mobility by suppressing surface-defect-related scattering. The coexistence of multiple types of carriers and inhomogeneous transport lead to the emergence of CPMR. This unit-cell-level surface engineering approach is promising to be generalized to others oxides, and to realize devices with high-mobility carriers and interesting magnetoelectronic properties.

  8. Research progress of on-line automatic monitoring of chemical oxygen demand (COD) of water

    Science.gov (United States)

    Cai, Youfa; Fu, Xing; Gao, Xiaolu; Li, Lianyin

    2018-02-01

    With the increasingly stricter control of pollutant emission in China, the on-line automatic monitoring of water quality is particularly urgent. The chemical oxygen demand (COD) is a comprehensive index to measure the contamination caused by organic matters, and thus it is taken as one important index of energy-saving and emission reduction in China’s “Twelve-Five” program. So far, the COD on-line automatic monitoring instrument has played an important role in the field of sewage monitoring. This paper reviews the existing methods to achieve on-line automatic monitoring of COD, and on the basis, points out the future trend of the COD on-line automatic monitoring instruments.

  9. A brief clinical case of monitoring of oxygenator performance and patient-machine interdependency during prolonged veno-venous extracorporeal membrane oxygenation.

    Science.gov (United States)

    Belliato, Mirko; Degani, Antonella; Buffa, Antonino; Sciutti, Fabio; Pagani, Michele; Pellegrini, Carlo; Iotti, Giorgio Antonio

    2017-10-01

    Monitoring veno-venous extracorporeal membrane oxygenation (vvECMO) during 76 days of continuous support in a 42-years old patient with end-stage pulmonary disease, listed for double-lung transplantation. Applying a new monitor (Landing ® , Eurosets, Medolla, Italy) and describing how measured and calculated parameters can be used to understand the variable interdependency between artificial membrane lung (ML) and patient native lung (NL). During vvECMO, in order to understand how the respiratory function is shared between ML and NL, ideally we should obtain data about oxygen transfer and CO 2 removal, both by ML and NL. Measurements for NL can be made on the mechanical ventilator. Measurements for ML are typically made from gas analysis on blood samples drawn from the ECMO system before and after the oxygenator, and therefore are non-continuous. Differently, the Landing monitor provides a continuous measurement of the oxygen transfer from the ML, combined with hemoglobin level, saturation of drained blood and saturation of reinfused blood. Moreover, the Landing monitor provides hemodynamics data about circulation through the ECMO system, with blood flow, pre-oxygenator pressure and post-oxygenator pressure. Of note, measurements include the drain negative pressure, whose monitoring may be particularly useful to prevent hemolysis. Real-time monitoring of vvECMO provides data helpful to understand the complex picture of a patient with severely damaged lungs on one side and an artificial lung on the other side. Data from vvECMO monitoring may help to adapt the settings of both mechanical ventilator and vvECMO. Data about oxygen transfer by the oxygenator are important to evaluate the performance of the device and may help to avoid unnecessary replacements, thus reducing risks and costs.

  10. (La1-xSrx)0.98MnO3 perovskite with A-site deficiencies toward oxygen reduction reaction in aluminum-air batteries

    Science.gov (United States)

    Xue, Yejian; Miao, He; Sun, Shanshan; Wang, Qin; Li, Shihua; Liu, Zhaoping

    2017-02-01

    The strontium doped Mn-based perovskites have been proposed as one of the best oxygen reduction reaction catalysts (ORRCs) to substitute the noble metal. However, few studies have investigated the catalytic activities of LSM with the A-site deficiencies. Here, the (La1-xSrx)0.98MnO3 (LSM) perovskites with A-site deficiencies are prepared by a modified solid-liquid method. The structure, morphology, valence state and oxygen adsorption behaviors of these LSM samples are characterized, and their catalytic activities toward ORR are studied by the rotating ring-disk electrode (RRDE) and aluminum-air battery technologies. The results show that the appropriate doping with Sr and introducing A-site stoichiometry can effectively tailor the Mn valence and increase the oxygen adsorption capacity of LSM. Among all the LSM samples in this work, the (La0.7Sr0.3)0.98MnO3 perovskite composited with 50% carbon (50%LSM30) exhibits the best ORR catalytic activity due to the excellent oxygen adsorption capacity. Also, this catalyst has much higher durability than that of commercial 20%Pt/C. Moreover, the maximum power density of the aluminum-air battery using 50%LSM30 as the ORRC can reach 191.3 mW cm-2. Our work indicates that the LSM/C composite catalysts with A-site deficiencies can be used as a promising ORRC in the metal-air batteries.

  11. Real-Time Molecular Monitoring of Chemical Environment in ObligateAnaerobes during Oxygen Adaptive Response

    Energy Technology Data Exchange (ETDEWEB)

    Holman, Hoi-Ying N.; Wozei, Eleanor; Lin, Zhang; Comolli, Luis R.; Ball, David. A.; Borglin, Sharon; Fields, Matthew W.; Hazen, Terry C.; Downing, Kenneth H.

    2009-02-25

    Determining the transient chemical properties of the intracellular environment canelucidate the paths through which a biological system adapts to changes in its environment, for example, the mechanisms which enable some obligate anaerobic bacteria to survive a sudden exposure to oxygen. Here we used high-resolution Fourier Transform Infrared (FTIR) spectromicroscopy to continuously follow cellular chemistry within living obligate anaerobes by monitoring hydrogen bonding in their cellular water. We observed a sequence of wellorchestrated molecular events that correspond to changes in cellular processes in those cells that survive, but only accumulation of radicals in those that do not. We thereby can interpret the adaptive response in terms of transient intracellular chemistry and link it to oxygen stress and survival. This ability to monitor chemical changes at the molecular level can yield important insights into a wide range of adaptive responses.

  12. Concurrent Longitudinal EPR Monitoring of Tissue Oxygenation, Acidosis, and Reducing Capacity in Mouse Xenograft Tumor Models.

    Science.gov (United States)

    Bobko, Andrey A; Evans, Jason; Denko, Nicholas C; Khramtsov, Valery V

    2017-06-01

    Tissue oxygenation, extracellular acidity, and tissue reducing capacity are among crucial parameters of tumor microenvironment (TME) of significant importance for tumor pathophysiology. In this paper, we demonstrate the complementary application of particulate lithium octa-n-butoxy-naphthalocyanine and soluble nitroxide paramagnetic probes for monitoring of these TME parameters using electron paramagnetic resonance (EPR) technique. Two different types of therapeutic interventions were studied: hypothermia and systemic administration of metabolically active drug. In summary, the results demonstrate the utility of EPR technique for non-invasive concurrent longitudinal monitoring of physiologically relevant chemical parameters of TME in mouse xenograft tumor models, including that under therapeutic intervention.

  13. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring

    OpenAIRE

    Mark van Gastel; Sander Stuijk; Gerard de Haan

    2016-01-01

    Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO2) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted ...

  14. Design of a tissue oxygenation monitor and verification on human skin

    Science.gov (United States)

    Liu, Hongyuan; Kohl-Bareis, Matthias; Huang, Xiabing

    2011-07-01

    We report the design of a tissue oxygen and temperature monitor. The non-invasive, fibre based device monitors tissue haemoglobin (Hb) and oxygen saturation (SO2) and is based on white-light reflectance spectroscopy.Visible light with wavelengths in the 500 - 650nm range is utilized. The spectroscopic algorithm takes into account the tissue scattering and melanin absorption for the calculation of tissue haemoglobin concentration and oxygen saturation. The monitor can probe superficial layers of tissue with a high spatial resolution (mm3) and a high temporal resolution (40 Hz). It provides an accurate measurement with the accuracy of SO2 at 2 % and high reliability with less than 2 % variation of continuous SO2 measurement over 12 hours. It can also form a modular system when used in conjunction with a laser Doppler monitor, enabling simultaneous measurements of Hb, SO2 and blood flow. We found experimentally that the influence of the source-detector separation on the haemoglobin parameters is small. This finding is discussed by Monte Carlo simulations for the depth sensitivity profile. The influence of probe pressure and the skin pigmentation on the measurement parameters are assessed before in vivo experimental data is presented. The combination with laser Doppler flowmetry demonstrates the importance of a measurement of both the haemoglobin and the blood flow parameters for a full description of blood tissue perfusion. This is discussed in experimental data on human skin during cuff occlusion and after hyperemisation by a pharmacological cream. Strong correlation is observed between tissue oxygen (Hb and SO2) and blood flow measurements.

  15. Diode laser spectroscopy for noninvasive monitoring of oxygen in the lungs of newborn infants.

    Science.gov (United States)

    Svanberg, Emilie Krite; Lundin, Patrik; Larsson, Marcus; Åkeson, Jonas; Svanberg, Katarina; Svanberg, Sune; Andersson-Engels, Stefan; Fellman, Vineta

    2016-04-01

    Newborn infants may have pulmonary disorders with abnormal gas distribution, e.g., respiratory distress syndrome. Pulmonary radiography is the clinical routine for diagnosis. Our aim was to investigate a novel noninvasive optical technique for rapid nonradiographic bedside detection of oxygen gas in the lungs of full-term newborn infants. Laser spectroscopy was used to measure contents of oxygen gas (at 760 nm) and of water vapor (at 937 nm) in the lungs of 29 healthy newborn full-term infants (birth weight 2,900-3,900 g). The skin above the lungs was illuminated using two low-power diode lasers and diffusely emerging light was detected with a photodiode. Of the total 390 lung measurements performed, clear detection of oxygen gas was recorded in 60%, defined by a signal-to-noise ratio of >3. In all the 29 infants, oxygen was detected. Probe and detector positions for optimal pulmonary gas detection were determined. There were no differences in signal quality with respect to gender, body side or body weight. The ability to measure pulmonary oxygen content in healthy full-term neonates with this technique suggests that with further development, the method might be implemented in clinical practice for lung monitoring in neonatal intensive care.

  16. Transport and magnetoresistance effect in an oxygen-deficient SrTiO3/La0.67Sr0.33MnO3 heterojunction

    International Nuclear Information System (INIS)

    Wang Jing; Chen Chang-Le; Yang Shi-Hai; Luo Bing-Cheng; Duan Meng-Meng; Jin Ke-Xin

    2013-01-01

    An oxygen-deficient SrTiO 3 /La 0.67 Sr 0.33 MnO 3 heterojunction is fabricated on an SrTiO 3 (001) substrate by a pulsed laser deposition method. The electrical characteristics of the heterojunction are studied systematically in a temperature range from 80 K to 300 K. The transport mechanism follows I ∞ exp(eV/nkT) under small forward bias, while it becomes space charge limited and follows I ∞ V m(T) with 1.49 < m < 1.99 under high bias. Such a heterojunction also exhibits magnetoresistance (MR) effect. The absolute value of negative MR monotonically increases with temperature decreasing and reaches 26.7% at 80 K under H = 0.7 T. Various factors, such as strain and oxygen deficiency play dominant roles in the characteristics. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  17. Effect of oxygen concentration on human embryo development evaluated by time-lapse monitoring

    DEFF Research Database (Denmark)

    Ingerslev, Hans Jakob; Hindkjær, Johnny Juhl; Kirkegaard, Kirstine

    2012-01-01

    -points for each cell division and blastocyst stages were registered until 120 hours after oocyte retrieval. Only 2PN embryos completing the first cleavage were evaluated. The groups were compared using one-way ANOVA or Kruskall-Wallis test. Estimates are reported as medians with 95% confidence intervals. Time......Introduction: Data from a number of studies indicate -but not unequivocally- that culture of embryos in 5% O2 compared to 20% O2 improves blastocyst formation in humans and various animal species and may yield better pregnancy rates in IVF. The detrimental effects of atmospheric oxygen were...... was to evaluate the influence of oxygen tension on human pre-implantation development using time-lapse monitoring. Materials and methods: Human embryos were cultured to the blastocyst stage in a time-lapse incubator (EmbryoScope™) in 20% O2 (group 1), 20% O2 for 24 hours followed by culture in 5% O2 (group 2...

  18. Optical monitoring of kidney oxygenation and hemodynamics using a miniaturized near-infrared sensor

    Science.gov (United States)

    Shadgan, Babak; Macnab, Andrew; Nigro, Mark; Nguan, Christopher

    2017-02-01

    Background: Following human renal allograft transplant primary graft dysfunction can occur early in the postoperative period as a result of acute tubular necrosis, acute rejection, drug toxicity, and vascular complications. Successful treatment of graft dysfunction requires early detection and accurate diagnosis so that disease-specific medical and/or surgical intervention can be provided promptly. However, current diagnostic methods are not sensitive or specific enough, so that identifying the cause of graft dysfunction is problematic and often delayed. Near-infrared spectroscopy (NIRS) is an established optical method that monitors changes in tissue hemodynamics and oxygenation in real time. We report the feasibility of directly monitoring kidney the kidney in an animal model using NIRS to detect renal ischemia and hypoxia. Methods: In an anesthetized pig, a customized continuous wave spatially resolved (SR) NIRS sensor was fixed directly to the surface of the surgically exposed kidney. Changes in the concentration of oxygenated (O2Hb) deoxygenated (HHb) and total hemoglobin (THb) were monitored before, during and after renal artery clamping and reperfusion, and the resulting fluctuations in chromophore concentration from baseline used to measure variations in renal perfusion and oxygenation. Results: On clamping the renal artery THb and O2Hb concentrations declined progressively while HHb rose. With reperfusion after releasing the artery clamp O2Hb and THb rose while HHb fell with all parameters returning to its baseline. This pattern was similar in all three trials. Conclusion: This pilot study indicates that a miniaturized NIRS sensor applied directly to the surface of a kidney in an animal model can detect the onset of renal ischemia and tissue hypoxia. With modification, our NIRS-based method may contribute to early detection of renal vascular complications and graft dysfunction following renal transplant.

  19. Real-Time In Vivo Monitoring of Reactive Oxygen Species in Guard Cells.

    Science.gov (United States)

    Park, Ky Young; Roubelakis-Angelakis, Kalliopi A

    2018-01-01

    The intra-/intercellular homeostasis of reactive oxygen species (ROS), and especially of superoxides (O 2 .- ) and hydrogen peroxide (O 2 .- ) participate in signalling cascades which dictate developmental processes and reactions to biotic/abiotic stresses. Polyamine oxidases terminally oxidize/back convert polyamines generating H 2 O 2 . Recently, an NADPH-oxidase/Polyamine oxidase feedback loop was identified to control oxidative burst under salinity. Thus, the real-time localization/monitoring of ROS in specific cells, such as the guard cells, can be of great interest. Here we present a detailed description of the real-time in vivo monitoring of ROS in the guard cells using H 2 O 2 - and O 2 .- specific fluorescing probes, which can be used for studying ROS accumulation generated from any source, including the amine oxidases-dependent pathway, during development and stress.

  20. The design of a PC-based real-time system for monitoring Methane and Oxygen concentration in biogas production

    Science.gov (United States)

    Yantidewi, M.; Muntini, M. S.; Deta, U. A.; Lestari, N. A.

    2018-03-01

    Limited fossil fuels nowadays trigger the development of alternative energy, one of which is biogas. Biogas is one type of bioenergy in the form of fermented gases of organic materials such as animal waste. The components of gases present in biogas and affect the biogas production are various, such as methane and oxygen. The biogas utilization will be more optimal if both gases concentration (in this case is methane and oxygen concentration) can be monitored. Therefore, this research focused on designing the monitoring system of methane and oxygen concentration in biogas production in real-time. The results showed that the instrument system was capable of monitoring and recording the data of gases (methane and oxygen) concentration in biogas production in every second.

  1. Combined effect of oxygen deficient point defects and Ni doping in radio frequency magnetron sputtering deposited ZnO thin films

    Energy Technology Data Exchange (ETDEWEB)

    Saha, B., E-mail: biswajit.physics@gmail.com [Thin Film and Nano Science Laboratory, Department of Physics, Jadavpur University, 700 032 Kolkata (India); Department of Physics, National Institute of Technology Agartala, Jirania 799046, Tripura (India); Das, N.S.; Chattopadhyay, K.K. [Thin Film and Nano Science Laboratory, Department of Physics, Jadavpur University, 700 032 Kolkata (India)

    2014-07-01

    Ni doped ZnO thin films with oxygen deficiency have been synthesized on glass substrates by radio frequency magnetron sputtering technique using argon plasma. The combined effect of point defects generated due to oxygen vacancies and Ni doping on the optical and electrical properties of ZnO thin films has been studied in this work. Ni doping concentrations were varied and the structural, optical and electrical properties of the films were studied as a function of doping concentrations. The films were characterized with X-ray diffractometer, UV–Vis–NIR spectrophotometer, X-ray photoelectron spectroscopy, atomic force microscopy and electrical conductivity measurements. Oxygen deficient point defects (Schottky defects) made the ZnO thin film highly conducting while incorporation of Ni dopant made it more functional regarding their electrical and optical properties. The films were found to have tunable electrical conductivity with Ni doping concentrations. - Highlights: • ZnO thin films prepared by radio frequency magnetron sputtering technique • Synthesis process was stimulated to introduce Schottky-type point defects. • Point defects and external doping of Ni made ZnO thin films more functional. • Point defect induced high electrical conductivity in ZnO thin film. • Significant shift in optical bandgap observed in ZnO with Ni doping concentrations.

  2. Monitoring Cerebral and Renal Oxygenation Status during Neonatal Digestive Surgeries Using Near Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Jonathan Beck

    2017-06-01

    Full Text Available BackgroundDepending on the initial pathology, hypovolemia, intra-abdominal hypertension, and sepsis are often encountered in neonatal digestive surgery. Accurate newborn monitoring during and after surgery is essential to adapt resuscitation protocols. Near infrared spectroscopy (NIRS is non-invasive and can detect hypoperfusion which indicates a low circulatory blood flow, regardless of the cause.ObjectiveEvaluating changes in cerebral and renal regional oxygen saturation during neonatal digestive surgeries, conducted according to normal practices, with commonly used monitoring parameters. Analyzing retrospectively the inter-relationships between NIRS values and mean arterial pressure (MAP values as well as pre-ductal SpO2.MethodsProspective, descriptive, monocentric study. All neonates referred for surgery were included. NIRS allows the measurement of cerebral and renal oxygenation fluctuations, as well as calculating difference in intraoperative and postoperative values.ResultsNineteen patients were included. Cerebral regional oxygen saturation (C rSO2 values were stable while renal regional oxygen saturation (R rSO2 values tended to decrease with time during surgery. Indeed, 72% of rSO2 decline episodes occurred after the first 30 min of surgery, without any significant statistical differences for the next 90 min of surgery. After surgery, the lowest average C and R rSO2 values were evidenced during the first 6 h, with 60% of C rSO2 and R rSO2 anomalies occurring in that time frame. There was no significant statistical difference observed in the following 18 h. There was a significant correlation between R rSO2 and SpO2 values (p < 0.01, but not with C rSO2 values. There was no correlation with the MAP either for the C rSO2 values or R rSO2 ones.ConclusionNIRS is a promising non-invasive bedside tool to monitor cerebral and tissue perfusion, analyzing tissue microcirculation. NIRS has its interest to guide neonatal digestive

  3. Cerebral oxygenation monitoring in patients with bilateral carotid stenosis undergoing urgent cardiac surgery: Observational case series

    Directory of Open Access Journals (Sweden)

    Dincer Aktuerk

    2016-01-01

    Full Text Available Background: Patients with significant bilateral carotid artery stenosis requiring urgent cardiac surgery have an increased risk of stroke and death. The optimal management strategy remains inconclusive, and the available evidence does not support the superiority of one strategy over another. Materials and Methods: A number of noninvasive strategies have been developed for minimizing perioperative stroke including continuous real-time monitoring of cerebral oxygenation with near-infrared spectroscopy (NIRS. The number of patients presenting with this combination (bilateral significant carotid stenosis requiring urgent cardiac surgery in any single institution will be small and hence there is a lack of large randomized studies. Results: This case series describes our early experience with NIRS in a select group of patients with significant bilateral carotid stenosis undergoing urgent cardiac surgery (n = 8. In contrast to other studies, this series is a single surgeon, single center study, where the entire surgery (both distal ends and proximal ends was performed during single aortic clamp technique, which effectively removes several confounding variables. NIRS monitoring led to the early recognition of decreased cerebral oxygenation, and corrective steps (increased cardiopulmonary bypass flow, increased pCO 2 , etc., were taken. Conclusion: The study shows good clinical outcome with the use of NIRS. This is our "work in progress," and we aim to conduct a larger study.

  4. In-vivo continuous monitoring of mixed venous oxygen saturation by photoacoustic transesophageal echocardiography (Conference Presentation)

    Science.gov (United States)

    Li, Li; Subramaniam, Balachundhar; Aguirre, Aaron D.; Andrawes, Michael N.; Tearney, Guillermo J.

    2016-02-01

    Mixed venous oxygen saturation (SvO2), measured from pulmonary arteries, is a gold-standard measure of the dynamic balance between the oxygen supply and demand in the body. In critical care, continuous monitoring of SvO2 plays a vital role in early detection of circulatory shock and guiding goal-oriented resuscitation. In current clinical practice, SvO2 is measured by invasive pulmonary artery catheters (PAC), which are associated with a 10% risk of severe complications. To address the unmet clinical need for a non-invasive SvO2 monitor, we are developing a new technology termed photoacoustic transesophageal echocardiography (PA-TEE). PA-TEE integrates transesophageal echocardiography with photoacoustic oximetry, and enables continuous assessment of SvO2 through an esophageal probe that can be inserted into the body in a minimally invasive manner. We have constructed a clinically translatable PA-TEE prototype, which features a mobile OPO laser, a modified ultrasonography console and a dual-modality esophageal probe. Comprised of a rotatable acoustic array detector, a flexible optical fiber bundle and a light-integrating acoustic lens, the oximetric probe has an outer diameter smaller than 15 mm and will be tolerable for most patients. Through custom-made C++/Qt software, our device acquires and displays ultrasonic and photoacoustic images in real time to guide the deployment of the probe. SvO2 is calculated on-line and updated every second. PA-TEE has now been used to evaluate SvO2 in living swine. Our findings show that changing the fraction of oxygen in the inspired gas modulates SvO2 measured by PA-TEE. Statistic comparison between SvO2 measurements from PA-TEE in vivo the gold-standard laboratorial analysis on blood samples drawn from PACs will be presented.

  5. Mass-specific respiration of mesozooplankton and its role in the maintenance of an oxygen-deficient ecological barrier (BEDOX) in the upwelling zone off Chile upon presence of a shallow oxygen minimum zone

    Science.gov (United States)

    Donoso, Katty; Escribano, Ruben

    2014-01-01

    A shallow oxygen minimum zone (OMZ) in the coastal upwelling zone off Chile may vertically confine most zooplankton to a narrow (oxygen consumption of the mesozooplankton community obtained in Bay of Mejillones, northern Chile (23°S) in May 2010, December 2010 and August 2011. Mass-specific respiration rates were in the range of 8.2-24.5 μmol O2 mg dry mass- 1 day- 1, at an average temperature of 12 °C. Estimates of the mesozooplankton biomass in the water column indicated that its aerobic respiration may remove daily a maximum of about 20% of oxygen available at the base of the oxycline. Since previous work indicates that zooplankton aggregate near the base of the oxycline, the impact of aerobic respiration on oxygen content might be even stronger at this depth. Mesozooplankton respiration, along with community respiration by microorganisms near the base of the oxycline and a strongly stratified condition (limiting vertical flux of O2), are suggested as being critical factors causing and maintaining a persistent subsurface oxygen-deficient ecological barrier (BEDOX) in the upwelling zone. This BEDOX layer can have a major role in affecting and regulating zooplankton distribution and their dynamics in the highly productive coastal upwelling zone of the Humboldt Current System.

  6. Noninvasive diffuse optical monitoring of head and neck tumor blood flow and oxygenation during radiation delivery

    Science.gov (United States)

    Dong, Lixin; Kudrimoti, Mahesh; Cheng, Ran; Shang, Yu; Johnson, Ellis L.; Stevens, Scott D.; Shelton, Brent J.; Yu, Guoqiang

    2012-01-01

    This study explored using a novel diffuse correlation spectroscopy (DCS) flow-oximeter to noninvasively monitor blood flow and oxygenation changes in head and neck tumors during radiation delivery. A fiber-optic probe connected to the DCS flow-oximeter was placed on the surface of the radiologically/clinically involved cervical lymph node. The DCS flow-oximeter in the treatment room was remotely operated by a computer in the control room. From the early measurements, abnormal signals were observed when the optical device was placed in close proximity to the radiation beams. Through phantom tests, the artifacts were shown to be caused by scattered x rays and consequentially avoided by moving the optical device away from the x-ray beams. Eleven patients with head and neck tumors were continually measured once a week over a treatment period of seven weeks, although there were some missing data due to the patient related events. Large inter-patient variations in tumor hemodynamic responses were observed during radiation delivery. A significant increase in tumor blood flow was observed at the first week of treatment, which may be a physiologic response to hypoxia created by radiation oxygen consumption. Only small and insignificant changes were found in tumor blood oxygenation, suggesting that oxygen utilizations in tumors during the short period of fractional radiation deliveries were either minimal or balanced by other effects such as blood flow regulation. Further investigations in a large patient population are needed to correlate the individual hemodynamic responses with the clinical outcomes for determining the prognostic value of optical measurements. PMID:22312579

  7. Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring

    Science.gov (United States)

    Hunter, Gary W.; Xu, Jennifer C.; Liu, Chung-Chiun

    2011-01-01

    An ambient temperature oxygen microsensor, based on a Nafion polymer electrolyte, has been developed and was microfabricated using thin-film technologies. A challenge in the operation of Nafion-based sensor systems is that the conductivity of Nafion film depends on the humidity in the film. Nafion film loses conductivity when the moisture content in the film is too low, which can affect sensor operation. The advancement here is the identification of a method to retain the operation of the Nafion films in lower humidity environments. Certain salts can hold water molecules in the Nafion film structure at room temperature. By mixing salts with the Nafion solution, water molecules can be homogeneously distributed in the Nafion film increasing the film s hydration to prevent Nafion film from being dried out in low-humidity environment. The presence of organics provides extra sites in the Nafion film to promote proton (H+) mobility and thus improving Nafion film conductivity and sensor performance. The fabrication of ambient temperature oxygen microsensors includes depositing basic electrodes using noble metals, and metal oxides layer on one of the electrode as a reference electrode. The use of noble metals for electrodes is due to their strong catalytic properties for oxygen reduction. A conducting polymer Nafion, doped with water-retaining components and extra sites facilitating proton movement, was used as the electrolyte material, making the design adequate for low humidity environment applications. The Nafion solution was coated on the electrodes and air-dried. The sensor operates at room temperature in potentiometric mode, which measures voltage differences between working and reference electrodes in different gases. Repeat able responses to 21-percent oxygen in nitrogen were achieved using nitrogen as a baseline gas. Detection of oxygen from 7 to 21 percent has also been demonstrated. The room-temperature oxygen micro sensor developed has extremely low power

  8. Enhanced magnetoresistance induced by oxygen deficiency in La0.4Ca0.6MnO3-δ oxides

    International Nuclear Information System (INIS)

    Triki, M.; Dhahri, E.; Hlil, E. K.; Garden, J. L.

    2014-01-01

    We report electrical features and magnetoresistance behavior of the oxygen deficient La 0.4 Ca 0.6 MnO 3-δ perovskites (δ = 0, 0.15, and 0.2). These samples will be referred to as S0, S15, and S20, respectively. The dependence of electrical transport on temperature and magnetic field is systematically investigated between 2 K and 400 K in magnetic field ranging up to 5 T. The parent compound shows a stable charge ordering/antiferromagnetic state with a semiconductor-like behavior in all considered temperature range. The variable range hopping and thermally activated hopping models are found to fit well with the electrical resistivity data at low and high temperatures, respectively. Oxygen deficiency tends to weaken the charge ordering and induce ferromagnetism and metallicity at low temperature. Metal insulator transition appears at higher fields for lower oxygen deficit (S15 sample) and without field for the S20 sample. The resistivity data for S15 sample are discussed in the framework of the variable-range hopping model. Abnormal transport properties were observed in the S20 sample, characterized by the double metal-insulator transitions and low minimum behavior. These results are discussed in terms of phenomenological percolation model, based on the phase segregation of ferromagnetic metallic clusters and paramagnetic insulating regions. While the parent compound shows no magnetoresistance, a large magnetoresistance is observed in the deficient samples at low temperature reaching 90% and 75% at 2 T for S15 and S20 samples, respectively. Noticeably, these values reached 98% and 91% at 5 T. The appearance of colossal magnetoresistance is attributed to the spin dependent hopping between spin clusters and/or ferromagnetic domains

  9. Intrinsic ZnO films fabricated by DC sputtering from oxygen-deficient targets for Cu(In,Ga)Se2 solar cell application

    Institute of Scientific and Technical Information of China (English)

    Chongyin Yang; DongyunWan; Zhou Wang; Fuqiang Huang

    2011-01-01

    Intrinsic zinc oxide films, normally deposited by radio frequency (RF) sputtering, are fabricated by direct current (DC) sputtering. The oxygen-deficient targets are prepared via a newly developed double crucible method. The 800-nm-thick film obtaines significantly higher carrier mobility compareing with that of the 800-nm-thick ZnO film. This is achieved by the widely used RF sputtering, which favors the prevention of carrier recombination at the interfaces and reduction of the series resistance of solar cells. The optimal ZnO film is used in a Cu (In, Ga) Se2 (CIGS) solar cell with a high efficiency of 11.57%. This letter demonstrates that the insulating ZnO films can be deposited by DC sputtering from oxygen-deficient ZnO targets to lower the cost of thin film solar cells.%Intrinsic zinc oxide films,normally deposited by radio frequency (RF) sputtering,are fabricated by direct current (DC) sputtering.The oxygen-deficient targets are prepared via a newly developed double crucible method.The 800-nm-thick film obtaines significantly higher carrier mobility compareing with that of the 800-nm-thick ZnO film.This is achieved by the widely used RF sputtering,which favors the prevention of carrier recombination at the interfaces and reduction of the series resistance of solar cells.The optimal ZnO film is used in a Cu (In,Ga) Se2 (C1GS) solar cell with a high efficiency of 11.57%.This letter demonstrates that the insulating ZnO films can be deposited by DC sputtering from oxygen-deficient ZnO targets to lower the cost of thin film solar cells.High resistance transparent intrinsic zinc oxide (i-ZnO)thin film has been widely nsed as the front electrode in transparent electronics and photovoltaic devices because of its low cost and nontoxicity.Owing to its unique characteristics of high transparency and adjustable resistivity in a certain range,the use of i-ZnO thin films as diffusion barrier layers of a-Si/μc-Si,CdTe,and CIGS thin-film solar cells has been advantageous

  10. Study and Development of a Fluorescence Based Sensor System for Monitoring Oxygen in Wine Production: The WOW Project.

    Science.gov (United States)

    Trivellin, Nicola; Barbisan, Diego; Badocco, Denis; Pastore, Paolo; Meneghesso, Gaudenzio; Meneghini, Matteo; Zanoni, Enrico; Belgioioso, Giuseppe; Cenedese, Angelo

    2018-04-07

    The importance of oxygen in the winemaking process is widely known, as it affects the chemical aspects and therefore the organoleptic characteristics of the final product. Hence, it is evident the usefulness of a continuous and real-time measurements of the levels of oxygen in the various stages of the winemaking process, both for monitoring and for control. The WOW project (Deployment of WSAN technology for monitoring Oxygen in Wine products) has focused on the design and the development of an innovative device for monitoring the oxygen levels in wine. This system is based on the use of an optical fiber to measure the luminescent lifetime variation of a reference metal/porphyrin complex, which decays in presence of oxygen. The developed technology results in a high sensitivity and low cost sensor head that can be employed for measuring the dissolved oxygen levels at several points inside a wine fermentation or aging tank. This system can be complemented with dynamic modeling techniques to provide predictive behavior of the nutrient evolution in space and time given few sampled measuring points, for both process monitoring and control purposes. The experimental validation of the technology has been first performed in a controlled laboratory setup to attain calibration and study sensitivity with respect to different photo-luminescent compounds and alcoholic or non-alcoholic solutions, and then in an actual case study during a measurement campaign at a renown Italian winery.

  11. Study and Development of a Fluorescence Based Sensor System for Monitoring Oxygen in Wine Production: The WOW Project

    Science.gov (United States)

    Trivellin, Nicola; Barbisan, Diego; Badocco, Denis; Pastore, Paolo; Meneghini, Matteo; Zanoni, Enrico; Belgioioso, Giuseppe

    2018-01-01

    The importance of oxygen in the winemaking process is widely known, as it affects the chemical aspects and therefore the organoleptic characteristics of the final product. Hence, it is evident the usefulness of a continuous and real-time measurements of the levels of oxygen in the various stages of the winemaking process, both for monitoring and for control. The WOW project (Deployment of WSAN technology for monitoring Oxygen in Wine products) has focused on the design and the development of an innovative device for monitoring the oxygen levels in wine. This system is based on the use of an optical fiber to measure the luminescent lifetime variation of a reference metal/porphyrin complex, which decays in presence of oxygen. The developed technology results in a high sensitivity and low cost sensor head that can be employed for measuring the dissolved oxygen levels at several points inside a wine fermentation or aging tank. This system can be complemented with dynamic modeling techniques to provide predictive behavior of the nutrient evolution in space and time given few sampled measuring points, for both process monitoring and control purposes. The experimental validation of the technology has been first performed in a controlled laboratory setup to attain calibration and study sensitivity with respect to different photo-luminescent compounds and alcoholic or non-alcoholic solutions, and then in an actual case study during a measurement campaign at a renown Italian winery. PMID:29642468

  12. Real-Time Monitoring of Singlet Oxygen and Oxygen Partial Pressure During the Deep Photodynamic Therapy In Vitro.

    Science.gov (United States)

    Li, Weitao; Huang, Dong; Zhang, Yan; Liu, Yangyang; Gu, Yueqing; Qian, Zhiyu

    2016-09-01

    Photodynamic therapy (PDT) is an effective noninvasive method for the tumor treatment. The major challenge in current PDT research is how to quantitatively evaluate therapy effects. To our best knowledge, this is the first time to combine multi-parameter detection methods in PDT. More specifically, we have developed a set of system, including the high-sensitivity measurement of singlet oxygen, oxygen partial pressure and fluorescence image. In this paper, the detection ability of the system was validated by the different concentrations of carbon quantum dots. Moreover, the correlation between singlet oxygen and oxygen partial pressure with laser irradiation was observed. Then, the system could detect the signal up to 0.5 cm tissue depth with 660 nm irradiation and 1 cm tissue depth with 980 nm irradiation by using up-conversion nanoparticles during PDT in vitro. Furthermore, we obtained the relationship among concentration of singlet oxygen, oxygen partial pressure and tumor cell viability under certain conditions. The results indicate that the multi-parameter detection system is a promising asset to evaluate the deep tumor therapy during PDT. Moreover, the system might be potentially used for the further study in biology and molecular imaging.

  13. Evaluation of tissue oxygen measurements for flap monitoring in an animal model

    DEFF Research Database (Denmark)

    Bonde, Christian; Elberg, Jens; Holstein-Rathlou, N.-H.

    2008-01-01

    Tissue oxygen tension (p(ti)O(2)) measurements are common in neurosurgery but uncommon in plastic surgery. We examined this technique as a monitoring method with probe placement in the subcutaneous tissue and addressed the importance of probe placement. Myocutaneous flaps were raised in an animal...... model and p(ti)O(2) measurements performed at different levels in the subcutaneous fat. Flap artery and vein were occluded until a 50% p(ti)O(2) reduction had occurred (T(1/2)). We found no significant effect of depth (P>0.10) on the level of p(ti)O(2). T(1/2)(arterial) was 7.2 minutes and T(1/2)(venous......) was 18 minutes. We found no significant relation between initial levels of p(ti)O(2) and T(1/2). Location of the probe and absolute p(ti)O(2) value is of little relevance for flap monitoring. It is the relative change in p(ti)O(2) that is important. The p(ti)O(2) technique is well suited for monitoring...

  14. Monitoring mixed venous oxygen saturation in patients with obstructive shock after massive pulmonary embolism.

    Science.gov (United States)

    Krivec, Bojan; Voga, Gorazd; Podbregar, Matej

    2004-05-31

    Patients with massive pulmonary embolism and obstructive shock usually require hemodynamic stabilization and thrombolysis. Little is known about the optimal and proper use of volume infusion and vasoactive drugs, or about the titration of thrombolytic agents in patients with relative contraindication for such treatment. The aim of the study was to find the most rapidly changing hemodynamic variable to monitor and optimize the treatment of patients with obstructive shock following massive pulmonary embolism. Ten consecutive patients hospitalized in the medical intensive care unit in the community General Hospital with obstructive shock following massive pulmonary embolism were included in the prospective observational study. Heart rate, systolic arterial pressure, central venous pressure, mean pulmonary-artery pressure, cardiac index, total pulmonary vascular-resistance index, mixed venous oxygen saturation, and urine output were measured on admission and at 1, 2, 3, 4, 8, 12, and 16 hours. Patients were treated with urokinase through the distal port of a pulmonary-artery catheter. At 1 hour, mixed venous oxygen saturation, systolic arterial pressure and cardiac index were higher than their admission values (31+/-10 vs. 49+/-12%, p<0.0001; 86+/-12 vs. 105+/-17 mmHg, p<0.01; 1.5+/-0.4 vs. 1.9+/-0.7 L/min/m2, p<0.05; respectively), whereas heart rate, central venous pressure, mean pulmonary-artery pressure and urine output remained unchanged. Total pulmonary vascular-resistance index was lower than at admission (29+/-10 vs. 21+/-12 mmHg/L/min/m2, p<0.05). The relative change of mixed venous oxygen saturation at hour 1 was higher than the relative changes of all other studied variables (p<0.05). Serum lactate on admission and at 12 hours correlated to mixed venous oxygen saturation (r=-0.855, p<0.001). In obstructive shock after massive pulmonary embolism, mixed venous oxygen saturation changes more rapidly than other standard hemodynamic variables.

  15. Design, fabrication, and analysis of miniature reflective oxygen monitoring system for use in PDT of esophageal carcinoma

    Science.gov (United States)

    Premasiri, Amaranath; Happawana, Gemunu

    2008-02-01

    Photodynamic therapy (PDT) is an effective and minimally invasive treatment modality with relatively less side effects, which is approved by FDA for the treatment of esophageal cancer. Maximum therapeutic outcome of the PDT protocol for each individual patient requires optimization of the components of PDT operating at their highest efficacy. Tumor necrosis, the method of malignant tissue destruction by PDT, is carried out by the toxic singlet oxygen molecules that are being formed from the molecular oxygen in the tumor. The availability of molecular oxygen, hence being the rate limiting step for PDT plays a key role in the treatment protocol. Currently the PDT of esophageal carcinoma is rather a blind process since there is no method to monitor the tumor oxygen level during the treatment. In this paper we present an optical technique to monitor molecular oxygen level in the PDT milieu. The technique described herein is a reflection oximetry technique designed with small semiconductor lasers and a silicon photodiode. The light used for monitoring system comes from two semiconductor diode lasers of 650 nm and 940 nm wavelengths. The two lasers and the photodiode are mounted onto a small package which is to be imprinted onto a balloon catheter containing the PDT light delivery system. Lasers and the photodiode are powered and controlled by a control box that is connected via a cable. Light sources and the respective photodiode output are controlled by the LabVIEW virtual instrumentation. The sequential on and off light source and the respective reflective signal are processed with MATLAB. The latter code integrates with LabVIEW to make an automatic calculation of the corresponding light absorption by each chromophore and to calculate the change in oxygen level as well as the amount of blood and oxygen present in the treatment area. The designed system is capable of monitoring the change in oxygen level and the blood flow in any part of the human body where the

  16. Effect of oxygen concentration on human embryo development evaluated by time-lapse monitoring

    DEFF Research Database (Denmark)

    Ingerslev, Hans Jakob; Hindkjær, Johnny Juhl; Kirkegaard, Kirstine

    2012-01-01

    recently demonstrated to occur from first cleavage cycle in mice using time-lapse microscopy, with the largest impact on the pre-compaction stages. However, embryonic development in mice differs in many aspects from human embryonic development. The objective of this retrospective, descriptive study...... was to evaluate the influence of oxygen tension on human pre-implantation development using time-lapse monitoring. Materials and methods: Human embryos were cultured to the blastocyst stage in a time-lapse incubator (EmbryoScope™) in 20% O2 (group 1), 20% O2 for 24 hours followed by culture in 5% O2 (group 2......) or in 5% O2 (group 3). Eligible were patients with age 8 oocytes retrieved. Group 1 consisted of 120 IVF/ICSI embryos from 26 patients recruited to a study conducted to evaluate the safety of the time-lapse incubator by randomising 1:1 embryos from a patient to culture...

  17. Brain and muscle oxygenation monitoring using near-infrared spectroscopy (NIRS) during all-night sleep

    Science.gov (United States)

    Zhang, Zhongxing; Khatami, Ramin

    2013-03-01

    The hemodynamic changes during natural human sleep are still not well understood. NIRS is ideally suited for monitoring the hemodynamic changes during sleep due to the properties of local measurement, totally safe application and good tolerance to motion. Several studies have been conducted using NIRS in both normal subjects and patients with various sleep disorders during sleep to characterize the hemodynamic changing patterns during different sleep stages and during different symptoms such as obstructive apneas. Here we assessed brain and muscle oxygenation changes in 7 healthy adults during all-night sleep with combined polysomnography measurement to test the notion if hemodynamic changes in sleep are indeed brain specific. We found that muscle and brain showed similar hemodynamic changes during sleep initiation. A decrease in HbO2 and tissue oxygenation index (TOI) while an increase in HHb was observed immediately after sleep onset, and an opposite trend was found after transition with progression to deeper slow-wave sleep (SWS) stage. Spontaneous low frequency oscillations (LFO) and very low frequency oscillations (VLFO) were smaller (Levene's test, psleep (LS) and rapid-eye-movement (REM) sleep in both brain and muscle. Spectral analysis of the NIRS signals measured from brain and muscle also showed reductions in VLFO and LFO powers during SWS with respect to LS and REM sleep. These results indicate a systemic attenuation rather than local cerebral reduction of spontaneous hemodynamic activity in SWS. A systemic physiological mechanism may exist to regulate the hemodynamic changes in brain and muscle during sleep.

  18. A new fibre optic pulse oximeter probe for monitoring splanchnic organ arterial blood oxygen saturation.

    Science.gov (United States)

    Hickey, M; Samuels, N; Randive, N; Langford, R; Kyriacou, P A

    2012-12-01

    A new, continuous method of monitoring splanchnic organ oxygen saturation (SpO(2)) would make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischaemia, and, ultimately, death. In an attempt to provide such a device, a new fibre optic based reflectance pulse oximeter probe and processing system were developed followed by an in vivo evaluation of the technology on seventeen patients undergoing elective laparotomy. Photoplethysmographic (PPG) signals of good quality and high signal-to-noise ratio were obtained from the small bowel, large bowel, liver and stomach. Simultaneous peripheral PPG signals from the finger were also obtained for comparison purposes. Analysis of the amplitudes of all acquired PPG signals indicated much larger amplitudes for those signals obtained from splanchnic organs than those obtained from the finger. Estimated SpO(2) values for splanchnic organs showed good agreement with those obtained from the finger fibre optic probe and those obtained from a commercial device. These preliminary results suggest that a miniaturized 'indwelling' fibre optic sensor may be a suitable method for pre-operative and post-operative evaluation of splanchnic organ SpO(2) and their health. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Correlations between the Hall coefficient and the superconducting transport properties of oxygen-deficient YBa2Cu3O7-δ epitaxial thin films

    International Nuclear Information System (INIS)

    Jones, E.C.; Christen, D.K.; Thompson, J.R.; Feenstra, R.; Zhu, S.; Lowndes, D.H.; Phillips, J.M.; Siegal, M.P.; Budai, J.D.

    1993-01-01

    Strong correlations between the Hall coefficient R H , the transition temperature T c , and the critical current density J c were established in a series of epitaxial YBa 2 Cu 3 O 7-δ thin films as a function of oxygen deficiency δ. Steady increases in R H with δ suggest that deoxygenation reduces the density of states which, according to BCS theory, should lead to corresponding decreases in T c . In contrast, two well-known plateaus occurring at 90 K and 60 K were observed in T c vs δ. Others have ascribed these plateaus to either electronic phenomena or phase separations. We find that in the 90-K plateau, the critical current density J c (δ,H=0) decreases with δ and extrapolates toward zero at the edge of the plateau, while the relative-field dependence of J c (δ,H) and the flux-creep pinning energies are independent of δ. These observations suggest that the phase-separation scenario occurs on the 90-K plateau. However, electronic origins cannot be ruled out at present due to difficulties in determining the equilibrium superconducting properties of oxygen-deficient YBa 2 Cu 3 O 7-δ films

  20. Oxygen effect on mutagenic ionizing radiation damage in Bacillus subtilis spores of DNA polymerase I-proficient and -deficient strains

    International Nuclear Information System (INIS)

    Tanooka, H.

    1980-01-01

    The nature of mutagenic ionizing radiation damage modified by the presence of oxygen or water was examined by comparing mutagenic with lethal expression of the damage in Bacillus subtilis spores irradiated with 6-MeV electrons. No specific difference was recognized between oxygen-dependent and -independent damages or between polA + -dependent and -independent damages with this system. The induced mutation frequency for His + mutation per lethal hit was 4.7 x 10 -5 for all tested cases

  1. Magnetoresistance Versus Oxygen Deficiency in Epi-stabilized SrRu1 - x Fe x O3 - δ Thin Films

    Science.gov (United States)

    Dash, Umasankar; Acharya, Susant Kumar; Lee, Bo Wha; Jung, Chang Uk

    2017-03-01

    Oxygen vacancies have a profound effect on the magnetic, electronic, and transport properties of transition metal oxide materials. Here, we studied the influence of oxygen vacancies on the magnetoresistance (MR) properties of SrRu1 - x Fe x O3 - δ epitaxial thin films ( x = 0.10, 0.20, and 0.30). For this purpose, we synthesized highly strained epitaxial SrRu1 - x Fe x O3 - δ thin films with atomically flat surfaces containing different amounts of oxygen vacancies using pulsed laser deposition. Without an applied magnetic field, the films with x = 0.10 and 0.20 showed a metal-insulator transition, while the x = 0.30 thin film showed insulating behavior over the entire temperature range of 2-300 K. Both Fe doping and the concentration of oxygen vacancies had large effects on the negative MR contributions. For the low Fe doping case of x = 0.10, in which both films exhibited metallic behavior, MR was more prominent in the film with fewer oxygen vacancies or equivalently a more metallic film. For semiconducting films, higher MR was observed for more semiconducting films having more oxygen vacancies. A relatively large negative MR ( 36.4%) was observed for the x = 0.30 thin film with a high concentration of oxygen vacancies ( δ = 0.12). The obtained results were compared with MR studies for a polycrystal of (Sr1 - x La x )(Ru1 - x Fe x )O3. These results highlight the crucial role of oxygen stoichiometry in determining the magneto-transport properties in SrRu1 - x Fe x O3 - δ thin films.

  2. Multi-Fibre Optode Microsensors: affordable designs for monitoring oxygen in soils under varying environmental conditions

    Science.gov (United States)

    Rezanezhad, F.; Milojevic, T.; Parsons, C. T.; Smeaton, C. M.; Van Cappellen, P.

    2017-12-01

    Molecular oxygen (O2) measurements in field and laboratory soil and sediment systems provide useful insight into the biogeochemical functioning of natural environments. However, monitoring soil and sediment O2 is often challenging due to high costs, analyte consumption, and limited customizability and durability of existing O2 sensors. To meet this challenge, an in-house luminescence-based Multi Fibre Optode (MuFO) microsensor system was developed to monitor O2 levels under changing moisture and temperature regimes. The design is simplified by the use of a basic DSLR camera, LED light and fibre optic cables. The technique is based on O2 quenching the luminescent light intensity emitted from a luminophore (platinum(II) meso-tetra(pentafluorophenyl)porphyrin, PtTFPP) that is dip-coated onto the tips of the fibre optic cables, where increasing O2 corresponds to decreasing light intensity, based on the classic Stern-Volmer relationship. High-resolution digital images of the sensor-emitted light are then converted into % O2 saturation. The method was successfully tested in two artificial soil (20% peat, 80% sand) column experiments designed to simulate freeze-thaw cycles (temperature cycling from -10°C to 25°C) and water table fluctuations under controlled conditions. Depth distributions of O2 levels were monitored without interruption for multiple freeze-thaw and water table cycles. No degradation of optode performance or O2 signals were observed for the duration of the column experiments, which supports the long-term deployment of the microsensors for continuous O2 monitoring in field and laboratory settings. The technical specifications of the system are fair, with a detection limit of 0.2% O2 saturation. The main advantages of the MuFO system over commercial applications are the comparatively low cost ($1,800 USD; about ¼ the cost of commercial versions) and ease of customizability. The system has been further developed for near real-time monitoring in the field

  3. CO2 reactivity and brain oxygen pressure monitoring in severe head injury.

    Science.gov (United States)

    Carmona Suazo, J A; Maas, A I; van den Brink, W A; van Santbrink, H; Steyerberg, E W; Avezaat, C J

    2000-09-01

    To investigate the effect of hyperventilation on cerebral oxygenation after severe head injury. A prospective, observational study. Neurointensive care unit at a university hospital. A total of 90 patients with severe head injury (Glasgow Coma Scale score brain tissue oxygen pressure (PbrO2) was performed as a measure of cerebral oxygenation. Arterial PCO2 was decreased each day over a 5-day period for 15 mins by increasing minute volume on the ventilator setting to 20% above baseline. Arterial blood gas analysis was performed before and after changing ventilator settings. Multimodality monitoring, including PbrO2, was performed in all patients. Absolute and relative PbrO2/PaCO2 reactivity was calculated. Outcome at 6 months was evaluated according to the Glasgow Outcome Scale. Effective hyperventilation, defined by a decrease of PaCO2 > or =2 torr (0.27 kPa), was obtained in 218 (84%) of 272 tests performed. Baseline PaCO2 averaged 32.3 +/- 4.5 torr (4.31 +/- 0.60 kPa). Average reduction in PaCO2 was 3.8 +/- 1.7 torr (0.51 +/- 0.23 kPa). PbrO2 decreased by 2.8 +/- 3.7 torr (0.37 +/- 0.49 kPa; p < .001) from a baseline value of 26.5 +/- 11.6 torr (3.53 +/- 1.55 kPa). PbrO2/PaCO2 reactivity was low on day 1 (0.8 +/- 2.3 torr [0.11 +/- 0.31 kPa]), increasing on subsequent days to 6.1 +/- 4.4 torr (0.81 +/- 0.59 kPa) on day 5. PbrO2/PaCO2 reactivity on days 1 and 2 was not related to outcome. In later phases in patients with unfavorable outcome, relative reactivity was increased more markedly, reaching statistical significance on day 5. Increased hyperventilation causes a significant reduction in PbrO2, providing further evidence for possible increased risk of secondary ischemic damage during hyperventilation. The low PbrO2/PaCO2 reactivity on day 1 indicates the decreased responsiveness of cerebral microvascular vessels to PaCO2 changes, caused by generalized vascular narrowing. The increasing PbrO2/PaCO2 reactivity from days 2 to 5 suggests that the risk of

  4. Real time continuous oxygen concentration monitoring system during malaxation for the production of Virgin Olive Oil

    Directory of Open Access Journals (Sweden)

    Aiello, G.

    2012-10-01

    Full Text Available During the mechanical extraction process of Virgin Olive Oil (VOO some important physical phenomena and enzymatic transformations occur which influence the quality of the final product. The control of process parameters is crucial to ensure the quality of VOO, therefore process monitoring and control is a fundamental requirement in the modern VOO processing industry. The present work proposes an innovative Real-Time Monitoring System (RTMS aimed at continuously measuring the oxygen concentration during the malaxation process in order to establish a correlation with the quality of the final product obtained. This monitoring system is based on an oxygen concentration sensor directly connected to the malaxation chamber and a data acquisition system to analyze and store the measured values in a process database. The experimental results obtained show that the use of oxygen during malaxation improves some qualitative parameters of VOO such as free fatty acids and total polyphenols while others (peroxide values and spectrophotometric indexes worsen. These results are similar to those obtained by employing nitrogen, which is the traditional technique to avoid the wellknown oxidation processes studied by several researchers, thus demonstrating that the presence of oxygen during the malaxation process can have beneficial effects on the quality of VOO when its concentration is properly controlled.

    Durante el proceso de extracción mecánica del aceite de oliva virgen ocurren importantes fenómenos físicos y transformaciones enzimáticas que influyen en la calidad del producto final. El control de los parámetros del proceso es crucial para garantizar la calidad del aceite de oliva virgen, por tanto la monitorización y el control del proceso son requisitos fundamentales en el moderno tratamiento industrial del aceite de oliva virgen. El presente trabajo propone un sistema de monitorización innovador en tiempo real dirigido a medir continuamente

  5. High Rate and Stable Li-Ion Insertion in Oxygen-Deficient LiV3O8 Nanosheets as a Cathode Material for Lithium-Ion Battery.

    Science.gov (United States)

    Song, Huanqiao; Luo, Mingsheng; Wang, Aimei

    2017-01-25

    Low performance of cathode materials has become one of the major obstacles to the application of lithium-ion battery (LIB) in advanced portable electronic devices, hybrid electric vehicles, and electric vehicles. The present work reports a versatile oxygen-deficient LiV 3 O 8 (D-LVO) nanosheet that was synthesized successfully via a facile oxygen-deficient hydrothermal reaction followed by thermal annealing in Ar. When used as a cathode material for LIB, the prepared D-LVO nanosheets display remarkable capacity properties at various current densities (a capacity of 335, 317, 278, 246, 209, 167, and 133 mA h g -1 at 50, 100, 200, 500, 1000, 2000, and 4000 mA g -1 , respectively) and excellent lithium-ion storage stability, maintaining more than 88% of the initial reversible capacity after 200 cycles at 1000 mA g -1 . The outstanding electrochemical properties are believed to arise largely from the introduction of tetravalent V (∼15% V 4+ ) and the attendant oxygen vacancies into LiV 3 O 8 nanosheets, leading to intrinsic electrical conductivity more than 1 order of magnitude higher and lithium-ion diffusion coefficient nearly 2 orders of magnitude higher than those of LiV 3 O 8 without detectable V 4+ (N-LVO) and thus contributing to the easy lithium-ion diffusion, rapid phase transition, and the excellent electrochemical reversibility. Furthermore, the more uniform nanostructure, as well as the larger specific surface area of D-LVO than N-LVO nanosheets may also improve the electrolyte penetration and provide more reaction sites for fast lithium-ion diffusion during the discharge/charge processes.

  6. Magnetism, Spin Texture, and In-Gap States: Atomic Specialization at the Surface of Oxygen-Deficient SrTiO_{3}.

    Science.gov (United States)

    Altmeyer, Michaela; Jeschke, Harald O; Hijano-Cubelos, Oliver; Martins, Cyril; Lechermann, Frank; Koepernik, Klaus; Santander-Syro, Andrés F; Rozenberg, Marcelo J; Valentí, Roser; Gabay, Marc

    2016-04-15

    Motivated by recent spin- and angular-resolved photoemission (SARPES) measurements of the two-dimensional electronic states confined near the (001) surface of oxygen-deficient SrTiO_{3}, we explore their spin structure by means of ab initio density functional theory (DFT) calculations of slabs. Relativistic nonmagnetic DFT calculations display Rashba-like spin winding with a splitting of a few meV and when surface magnetism on the Ti ions is included, bands become spin-split with an energy difference ∼100  meV at the Γ point, consistent with SARPES findings. While magnetism tends to suppress the effects of the relativistic Rashba interaction, signatures of it are still clearly visible in terms of complex spin textures. Furthermore, we observe an atomic specialization phenomenon, namely, two types of electronic contributions: one is from Ti atoms neighboring the oxygen vacancies that acquire rather large magnetic moments and mostly create in-gap states; another comes from the partly polarized t_{2g} itinerant electrons of Ti atoms lying further away from the oxygen vacancy, which form the two-dimensional electron system and are responsible for the Rashba spin winding and the spin splitting at the Fermi surface.

  7. Real-time monitoring of specific oxygen uptake rates of embryonic stem cells in a microfluidic cell culture device.

    Science.gov (United States)

    Super, Alexandre; Jaccard, Nicolas; Cardoso Marques, Marco Paulo; Macown, Rhys Jarred; Griffin, Lewis Donald; Veraitch, Farlan Singh; Szita, Nicolas

    2016-09-01

    Oxygen plays a key role in stem cell biology as a signaling molecule and as an indicator of cell energy metabolism. Quantification of cellular oxygen kinetics, i.e. the determination of specific oxygen uptake rates (sOURs), is routinely used to understand metabolic shifts. However current methods to determine sOUR in adherent cell cultures rely on cell sampling, which impacts on cellular phenotype. We present real-time monitoring of cell growth from phase contrast microscopy images, and of respiration using optical sensors for dissolved oxygen. Time-course data for bulk and peri-cellular oxygen concentrations obtained for Chinese hamster ovary (CHO) and mouse embryonic stem cell (mESCs) cultures successfully demonstrated this non-invasive and label-free approach. Additionally, we confirmed non-invasive detection of cellular responses to rapidly changing culture conditions by exposing the cells to mitochondrial inhibiting and uncoupling agents. For the CHO and mESCs, sOUR values between 8 and 60 amol cell(-1) s(-1) , and 5 and 35 amol cell(-1) s(-1) were obtained, respectively. These values compare favorably with literature data. The capability to monitor oxygen tensions, cell growth, and sOUR, of adherent stem cell cultures, non-invasively and in real time, will be of significant benefit for future studies in stem cell biology and stem cell-based therapies. © 2016 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. [Monitorization of the effects of spinal anaesthesia on cerebral oxygen saturation in elder patients using near-infrared spectroscopy].

    Science.gov (United States)

    Kusku, Aysegul; Demir, Guray; Cukurova, Zafer; Eren, Gulay; Hergunsel, Oya

    2014-01-01

    Central blockage provided by spinal anaesthesia enables realization of many surgical procedures, whereas hemodynamic and respiratory changes influence systemic oxygen delivery leading to the potential development of series of problems such as cerebral ischemia, myocardial infarction and acute renal failure. This study was intended to detect potentially adverse effects of hemodynamic and respiratory changes on systemic oxygen delivery using cerebral oxymetric methods in patients who underwent spinal anaesthesia. Twenty-five ASA I-II Group patients aged 65-80 years scheduled for unilateral inguinal hernia repair under spinal anaesthesia were included in the study. Following standard monitorization baseline cerebral oxygen levels were measured using cerebral oximetric methods. Standardized Mini Mental Test (SMMT) was applied before and after the operation so as to determine the level of cognitive functioning of the cases. Using a standard technique and equal amounts of a local anaesthetic drug (15mg bupivacaine 5%) intratechal blockade was performed. Mean blood pressure (MBP), maximum heart rate (MHR), peripheral oxygen saturation (SpO2) and cerebral oxygen levels (rSO2) were preoperatively monitored for 60min. Pre- and postoperative haemoglobin levels were measured. The variations in data obtained and their correlations with the cerebral oxygen levels were investigated. Significant changes in pre- and postoperative measurements of haemoglobin levels and SMMT scores and intraoperative SpO2 levels were not observed. However, significant variations were observed in intraoperative MBP, MHR and rSO2 levels. Besides, a correlation between variations in rSO2, MBP and MHR was determined. Evaluation of the data obtained in the study demonstrated that post-spinal decline in blood pressure and also heart rate decreases systemic oxygen delivery and adversely effects cerebral oxygen levels. However, this downward change did not result in deterioration of cognitive functioning

  9. Monitorization of the effects of spinal anaesthesia on cerebral oxygen saturation in elder patients using near-infrared spectroscopy.

    Science.gov (United States)

    Kusku, Aysegul; Demir, Guray; Cukurova, Zafer; Eren, Gulay; Hergunsel, Oya

    2014-01-01

    Central blockage provided by spinal anaesthesia enables realization of many surgical procedures, whereas hemodynamic and respiratory changes influence systemic oxygen delivery leading to the potential development of series of problems such as cerebral ischemia, myocardial infarction and acute renal failure. This study was intended to detect potentially adverse effects of hemodynamic and respiratory changes on systemic oxygen delivery using cerebral oxymetric methods in patients who underwent spinal anaesthesia. Twenty-five ASA I-II Group patients aged 65-80 years scheduled for unilateral inguinal hernia repair under spinal anaesthesia were included in the study. Following standard monitorization baseline cerebral oxygen levels were measured using cerebral oximetric methods. Standardized Mini Mental Test (SMMT) was applied before and after the operation so as to determine the level of cognitive functioning of the cases. Using a standard technique and equal amounts of a local anaesthetic drug (15mg bupivacaine 5%) intratechal blockade was performed. Mean blood pressure (MBP), maximum heart rate (MHR), peripheral oxygen saturation (SpO2) and cerebral oxygen levels (rSO2) were preoperatively monitored for 60min. Pre- and postoperative haemoglobin levels were measured. The variations in data obtained and their correlations with the cerebral oxygen levels were investigated. Significant changes in pre- and postoperative measurements of haemoglobin levels and SMMT scores and intraoperative SpO2 levels were not observed. However, significant variations were observed in intraoperative MBP, MHR and rSO2 levels. Besides, a correlation between variations in rSO2, MBP and MHR was determined. Evaluation of the data obtained in the study demonstrated that post-spinal decline in blood pressure and also heart rate decreases systemic oxygen delivery and adversely effects cerebral oxygen levels. However, this downward change did not result in deterioration of cognitive functioning

  10. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring.

    Science.gov (United States)

    van Gastel, Mark; Stuijk, Sander; de Haan, Gerard

    2016-12-07

    Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO 2 ) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO 2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted by motion-induced variations. We introduce a new principle that allows accurate remote measurements even during significant subject motion. We demonstrate the main advantage of the principle, i.e. that the optimal signature remains the same even when the SNR of the PPG signal drops significantly due to motion or limited measurement area. The evaluation uses recordings with breath-holding events, which induce hypoxemia in healthy moving subjects. The events lead to clinically relevant SpO 2 levels in the range 80-100%. The new principle is shown to greatly outperform current remote ratio-of-ratios based methods. The mean-absolute SpO 2 -error (MAE) is about 2 percentage-points during head movements, where the benchmark method shows a MAE of 24 percentage-points. Consequently, we claim ours to be the first method to reliably measure SpO 2 remotely during significant subject motion.

  11. The effect of short-term dimethylglycine treatment on oxygen consumption in cytochrome oxidase deficiency: a double-blind randomized crossover clinical trial.

    Science.gov (United States)

    Liet, Jean-Michel; Pelletier, Véronique; Robinson, Brian H; Laryea, Maurice D; Wendel, Udo; Morneau, Sylvain; Morin, Charles; Mitchell, Grant; Lacroix, Jacques

    2003-01-01

    To study the effectiveness of dimethylglycine (DMG) on oxygen consumption (VO(2)) in children with Saguenay-Lac-Saint-Jean cytochrome-c oxidase (SLSJ-COX) deficiency (OMIM 220111). In a crossover randomized double-blind clinical trial, 5 children with SLSJ-COX deficiency, who were stable and old enough to comply with VO(2) measurement, were treated with placebo or DMG for 3 days, and with the alternate treatment after a 2-week washout period. VO(2) was measured by indirect calorimetry before and after treatment. Dietary caloric intake was calculated for 3 days before each measurement. Mean caloric intakes per day were 1562 and 1342 kcal x m(-2) before and during placebo, 1,336 and 1,380 before and during DMG, respectively. DMG was well tolerated and, in all cases, resulted in markedly increased blood DMG levels (617 + 203 mmol x L(-1)), versus 0 to 2 mmol x L(-1) without treatment. Mean VO(2) was lower after administration of either DMG (-1 +/- 3 mL x min(-1) x m(-2)) or placebo (-6 +/- 4), but neither difference was statistically significant. There was no detectable effect of DMG treatment on blood levels of lactate, pyruvate, bicarbonate, or pH. VO(2) values of patients (range, 101-135 mL x min(-1) x m(-2)) were lower than published norms (150-160 mL x min(-1) x m(-2)). This study suggests that treatment with DMG does not substantially change VO(2) in children with SLSJ-COX deficiency.

  12. The human ear canal: investigation of its suitability for monitoring photoplethysmographs and arterial oxygen saturation

    International Nuclear Information System (INIS)

    Budidha, K; Kyriacou, P A

    2014-01-01

    For the last two decades, pulse oximetry has been used as a standard procedure for monitoring arterial oxygen saturation (SpO 2 ). However, SpO 2 measurements made from extremities such as the finger, ear lobe and toes become susceptible to inaccuracies when peripheral perfusion is compromised. To overcome these limitations, the external auditory canal has been proposed as an alternative monitoring site for estimating SpO 2 , on the hypothesis that this central site will be better perfused. Therefore, a dual wavelength optoelectronic probe along with a processing system was developed to investigate the suitability of measuring photoplethysmographic (PPG) signals and SpO 2 in the human auditory canal. A pilot study was carried out in 15 healthy volunteers to validate the feasibility of measuring PPGs and SpO 2  from the ear canal (EC), and comparative studies were performed by acquiring the same signals from the left index finger (LIF) and the right index finger (RIF) in conditions of induced peripheral vasoconstriction (right hand immersion in ice water). Good quality baseline PPG signals with high signal-to-noise ratio were obtained from the EC, the LIF and the RIF sensors. During the ice water immersion, significant differences in the amplitude of the red and infrared PPG signals were observed from the RIF and the LIF sensors. The average drop in amplitude of red and infrared PPG signals from the RIF was 52.7% and 58.3%. Similarly, the LIF PPG signal amplitudes have reduced by 47.52% and 46.8% respectively. In contrast, no significant changes were seen in the red and infrared EC PPG amplitude measurements, which changed by +2.5% and −1.2% respectively. The RIF and LIF pulse oximeters have failed to estimate accurate SpO 2  in seven and four volunteers respectively, while the EC pulse oximeter has only failed in one volunteer. These results suggest that the EC may be a suitable site for reliable monitoring of PPGs and SpO 2 s even in the presence of

  13. Science deficiency in conservation practice: the monitoring of tiger populations in India

    Science.gov (United States)

    Karanth, K.U.; Nichols, J.D.; Seidensticker, J.; Dinerstein, Eric; Smith, J.L.D.; McDougal, C.; Johnsingh, A.J.T.; Chundawat, Raghunandan S.; Thapar, V.

    2003-01-01

    Conservation practices are supposed to get refined by advancing scientific knowledge. We study this phenomenon in the context of monitoring tiger populations in India, by evaluating the 'pugmark census method' employed by wildlife managers for three decades. We use an analytical framework of modem animal population sampling to test the efficacy of the pugmark censuses using scientific data on tigers and our field observations. We identify three critical goals for monitoring tiger populations, in order of increasing sophistication: (1) distribution mapping, (2) tracking relative abundance, (3) estimation of absolute abundance. We demonstrate that the present census-based paradigm does not work because it ignores the first two simpler goals, and targets, but fails to achieve, the most difficult third goal. We point out the utility and ready availability of alternative monitoring paradigms that deal with the central problems of spatial sampling and observability. We propose an alternative sampling-based approach that can be tailored to meet practical needs of tiger monitoring at different levels of refinement.

  14. Combined Increases in Mitochondrial Cooperation and Oxygen Photoreduction Compensate for Deficiency in Cyclic Electron Flow in Chlamydomonas reinhardtii[W][OPEN

    Science.gov (United States)

    Dang, Kieu-Van; Plet, Julie; Tolleter, Dimitri; Jokel, Martina; Cuiné, Stéphan; Carrier, Patrick; Auroy, Pascaline; Richaud, Pierre; Johnson, Xenie; Alric, Jean; Allahverdiyeva, Yagut; Peltier, Gilles

    2014-01-01

    During oxygenic photosynthesis, metabolic reactions of CO2 fixation require more ATP than is supplied by the linear electron flow operating from photosystem II to photosystem I (PSI). Different mechanisms, such as cyclic electron flow (CEF) around PSI, have been proposed to participate in reequilibrating the ATP/NADPH balance. To determine the contribution of CEF to microalgal biomass productivity, here, we studied photosynthesis and growth performances of a knockout Chlamydomonas reinhardtii mutant (pgrl1) deficient in PROTON GRADIENT REGULATION LIKE1 (PGRL1)–mediated CEF. Steady state biomass productivity of the pgrl1 mutant, measured in photobioreactors operated as turbidostats, was similar to its wild-type progenitor under a wide range of illumination and CO2 concentrations. Several changes were observed in pgrl1, including higher sensitivity of photosynthesis to mitochondrial inhibitors, increased light-dependent O2 uptake, and increased amounts of flavodiiron (FLV) proteins. We conclude that a combination of mitochondrial cooperation and oxygen photoreduction downstream of PSI (Mehler reactions) supplies extra ATP for photosynthesis in the pgrl1 mutant, resulting in normal biomass productivity under steady state conditions. The lower biomass productivity observed in the pgrl1 mutant in fluctuating light is attributed to an inability of compensation mechanisms to respond to a rapid increase in ATP demand. PMID:24989042

  15. Structural and superconducting properties of oxygen-deficient NdBa sub 2 Cu sub 3 O sub 7 minus. delta

    Energy Technology Data Exchange (ETDEWEB)

    Shaked, H. (Nuclear Research Center-Negev, Post Office Box 9001, Beer Sheva, Israel (IL) Ben Gurion University of the Negev, Post Office Box 653, Beer Sheva, Israel (IL)); Veal, B.W.; Faber, J. Jr.; Hitterman, R.L.; Balachandran, U.; Tomlins, G.; Shi, H.; Morss, L.; Paulikas, A.P. (Argonne National Laboratory, Argonne, Illinois 60439 (USA))

    1990-03-01

    Neutron diffraction was used to determine the structural properties of oxygen deficient NdBa{sub 2}Cu{sub 3}O{sub 7{minus}{delta}} for 0.09{lt}{delta}{lt}0.74. It was found that superconductivity disappears at the orthorhombic-to-tetragonal phase transition which occurs at {delta}{sub {ital O}{ital T}}=0.45. Structural parameters vary smoothly with {delta} but exhibit a change in slope at the orthorhombic-to-tetragonal transition. The structural properties exhibit the same features found in YBa{sub 2}Cu{sub 3}O{sub 7{minus}{delta}} where {delta}{sub {ital O}{ital T}}=0.65. It is shown that the repulsion energy of oxygen atoms in the O(1) and O(5) sites in NdBa{sub 2}Cu{sub 3}O{sub 7{minus}{delta}} is smaller than in YBa{sub 2}Cu{sub 3}O{sub 7{minus}{delta}}. This lower repulsion energy stabilizes the orthorhombic phase at lower values of {delta}. It is argued that the disappearance of superconductivity at the orthorhombic-to-tetragonal transition is an inherent property of the {ital R}Ba{sub 2}Cu{sub 3}O{sub 7{minus}{delta}} ({ital R} denotes rare earth) system.

  16. Lung transplantation and survival outcomes in patients with oxygen-dependent COPD with regard to their alpha-1 antitrypsin deficiency status

    Directory of Open Access Journals (Sweden)

    Ekström M

    2017-11-01

    Full Text Available Magnus Ekström, Hanan Tanash Department of Respiratory Medicine and Allergology, Skåne University Hospital, Lund University, Lund, Sweden Background: Individuals with severe alpha-1 antitrypsin deficiency (AATD have an increased risk of developing COPD. However, outcomes during long-term oxygen therapy (LTOT in patients with severe AATD and hypoxemia are unknown.Patients and methods: This was a prospective, population-based, consecutive cohort study of patients on LTOT due to COPD in the period from January 1, 1987, to June 30, 2015, in the Swedish National Registry for Respiratory Failure (Swedevox. Severe AATD was identified using the Swedish AATD registry and confirmed by isoelectric focusing. Data on lung transplantation (LTx were obtained from the two lung transplantation centers in Sweden. Mortality and causes of death were assessed based on the National Causes of Death Registry and analyzed using multivariable Cox regression.Results: A total of 14,644 patients who started LTOT due to COPD were included in this study. No patient was lost to follow up. Patients with AATD were younger, included more males and more never smokers, and had fewer comorbidities. During a median follow-up of 1.6 years (interquartile range [IQR], 2.7 on LTOT, patients without severe AATD had a higher mortality, hazard ratio [HR] 1.53 (95% CI, 1.24–1.88, adjusting for age, sex, smoking status, body mass index, performance status, level of hypoxemia, and comorbidities. Cardiovascular deaths were increased. A higher proportion of AATD patients underwent LTx, 53 (19% vs 118 (1%. Survival after LTx was similar for AATD and non-AATD patients and was predicted by age.Conclusion: In oxygen-dependent COPD, patients with severe AATD have a longer survival time on LTOT, but they have a similar prognosis after lung transplantation compared with patients without AATD. Keywords: COPD, long-term oxygen therapy, lung transplantation, severe alpha-1 antitrypsin deficiency

  17. Hydrogen generation monitoring and mass gain analysis during the steam oxidation for Zircaloy using hydrogen and oxygen sensors

    International Nuclear Information System (INIS)

    Fukumoto, Michihisa; Hara, Motoi; Kaneko, Hiroyuki; Sakuraba, Takuya

    2015-01-01

    The oxidation behavior of Zircaloy-4 at high temperatures in a flowing Ar-H_2O (saturated at 323 K) mixed gas was investigated using hydrogen and oxygen sensors installed at a gas outlet, and the utility of the gas sensing methods by using both sensors was examined. The generated amount of hydrogen was determined from the hydrogen partial pressure continuously measured by the hydrogen sensor, and the resultant calculated oxygen amount that reacted with the specimen was in close agreement with the mass gain gravimetrically measured after the experiment. This result demonstrated that the hydrogen partial pressure measurement using a hydrogen sensor is an effective method for examining the steam oxidation of this metal as well as monitoring the hydrogen evolution. The advantage of this method is that the oxidation rate of the metal at any time as a differential quantity is able to be obtained, compared to the oxygen amount gravimetrically measured as an integral quantity. When the temperature was periodically changed in the range of 1173 K to 1523 K, highly accurate measurements could be carried out using this gas monitoring method, although reasonable measurements were not gravimetrically performed due to the fluctuating thermo-buoyancy during the experiment. A change of the oxidation rate was clearly detected at a monoclinic tetragonal transition temperature of ZrO_2. From the calculation of the water vapor partial pressure during the thermal equilibrium condition using the hydrogen and oxygen partial pressures, it became clear that a thermal equilibrium state is maintained when the isothermal condition is maintained, but is not when the temperature increases or decreases with time. Based on these results, it was demonstrated that the gas monitoring system using hydrogen and oxygen sensors is very useful for investigating the oxidation process of the Zircaloy in steam. (author)

  18. Oxygen sensor nanoparticles for monitoring bacterial growth and characterization of dose–response functions in microfluidic screenings

    International Nuclear Information System (INIS)

    Cao, Jialan; Köhler, J. Michael; Nagl, Stefan; Kothe, Erika

    2015-01-01

    We are presenting a microfluidic droplet-based system for non-invasive, simultaneous optical monitoring of oxygen during bacterial cultivation in nL-sized droplets using ∼350 nm nanobeads made from polystyrene and doped with the NIR-emitting oxygen probe platinum (II) 5, 10, 15, 20-meso-tetraphenyltetrabenzoporphyrin (PtTPTBP). Data were readout by a two-channel micro flow-through fluorimeter and a two-channel micro flow-through photometer. The time-resolved miniaturized optical multi endpoint detection was applied to simultaneously sense dissolved oxygen, cellular autofluorescence, and cell density in nL-sized segments. Two bacterial strains were studied that are resistant to heavy metal ions, viz. Streptomyces acidiscabies E13 and Psychrobacillus psychrodurans UrPLO1. The study has two main features in that it demonstrates (a) the possibility to monitor the changes in oxygen partial pressure during metabolic activity of different bacterial cultures inside droplets, and (b) the efficiency of droplet-based microfluidic techniques along with multi-parameter optical sensing for highly resolved microtoxicological screenings in aquatic systems. (author)

  19. Development of sensors for monitoring oxygen and free radicals in plant physiology

    Science.gov (United States)

    Chaturvedi, Prachee

    Oxygen plays a critical role in the physiology of photosynthetic organisms, including bioenergetics, metabolism, development, and stress response. Oxygen levels affect photosynthesis, respiration, and alternative oxidase pathways. Likewise, the metabolic rate of spatially distinct plant cells (and therefore oxygen flux) is known to be affected by biotic stress (e.g., herbivory) and environmental stress (e.g., salt/nutrient stress). During aerobic metabolism, cells produce reactive oxygen species (ROS) as a by product. Plants also produce ROS during adaptation to stress (e.g., abscisic acid (ABA) mediated stress responses). If stress conditions are prolonged, ROS levels surpass the capacity of detoxifying mechanisms within the cell, resulting in oxidative damage. While stress response pathways such as ABA-mediated mechanisms have been well characterized (e.g., water stress, inhibited shoot growth, synthesis of storage proteins in seeds), the connection between ROS production, oxygen metabolism and stress response remains unknown. In part, this is because details of oxygen transport at the interface of cell(s) and the surrounding microenvironment remains nebulous. The overall goal of this research was to develop oxygen and Free radical sensors for studying stress signaling in plants. Recent developments in nanomaterials and data acquisition systems were integrated to develop real-time, non-invasive oxygen and Free radical sensors. The availability of these sensors for plant physiologists is an exciting opportunity to probe the functional realm of cells and tissues in ways that were not previously possible.

  20. Discrepancies between measured changes of radiobiological hypoxic fraction and oxygen tension monitoring using two assay systems

    International Nuclear Information System (INIS)

    Sasai, K.; Brown, J.M.

    1994-01-01

    This study was conducted to assess the ability of computerized pO 2 histography to measure changes in tumor oxygenation produced by low oxygen breathing. Female syngeneic C3H/Km mice bearing SCC VII/St carcinomas were used in these experiments. Changes in tumor oxygenation produced by the mice breathing 10% oxygen were assessed with computerized pO2 histography, 3 H-misonidazole binding, and the paired survival curve assay of radiosensitivity. The hypoxic cell fraction of the tumors in mice breathing 10% oxygen was 3.1 times higher than that of tumors in mice breathing normal air determined by an in vivo-in vitro clonogenic assay. Binding of radiolabeled misonidazole to the tumors in mice breathing 10% oxygen was also significantly higher than that to tumors in mice breathing normal air (p 2 value for the tumor. The number of pO 2 readings lower than 5 mmHg in the tumor was not affected by the 10% oxygen breathing. These findings indicate that increases in radiobiological hypoxic fraction produced by lower blood oxygen levels may not correlate well with the results of polarographic measurements of tumor pO 2 levels. 29 refs., 4 figs., 1 tab

  1. Determination of Biochemical Oxygen Demand of Area Waters: A Bioassay Procedure for Environmental Monitoring

    Science.gov (United States)

    Riehl, Matthew

    2012-01-01

    A graphical method for determining the 5-day biochemical oxygen demand (BOD5) for a body of water is described. In this bioassay, students collect a sample of water from a designated site, transport it to the laboratory, and evaluate the amount of oxygen consumed by naturally occurring bacteria during a 5-day incubation period. An accuracy check,…

  2. The dynamics of dissolved oxygen concentration for water quality monitoring and assessment in polder ditches

    NARCIS (Netherlands)

    Veeningen, R.

    1983-01-01

    This study deals with the use of the dynamics of dissolved oxygen concentration for water quality assessment in polder ditches. The dynamics of the dissolved oxygen concentration, i.e. the temporal and spatial variations in a few polder ditches under a range of natural, pollution and management

  3. Brca1/p53 deficient mouse breast tumor hemodynamics during hyperoxic respiratory challenge monitored by a novel wide-field functional imaging (WiFI) system

    Science.gov (United States)

    Moy, Austin; Kim, Jae G.; Lee, Eva Y. H. P.; Tromberg, Bruce; Cerussi, Albert; Choi, Bernard

    2009-02-01

    Current imaging modalities allow precise visualization of tumors but do not enable quantitative characterization of the tumor metabolic state. Such quantitative information would enhance our understanding of tumor progression and response to treatment, and to our overall understanding of tumor biology. To address this problem, we have developed a wide-field functional imaging (WiFI) instrument which combines two optical imaging modalities, spatially modulated imaging (MI) and laser speckle imaging (LSI). Our current WiFI imaging protocol consists of multispectral imaging in the near infrared (650-980 nm) spectrum, over a wide (7 cm × 5 cm) field of view. Using MI, the spatially-resolved reflectance of sinusoidal patterns projected onto the tissue is assessed, and optical properties of the tissue are estimated using a Monte Carlo model. From the spatial maps of local absorption and reduced scattering coefficients, tissue composition information is extracted in the form of oxy-, deoxy-, and total hemoglobin concentrations, and percentage of lipid and water. Using LSI, the reflectance of a 785 nm laser speckle pattern on the tissue is acquired and analyzed to compute maps of blood perfusion in the tissue. Tissue metabolism state is estimated from the values of blood perfusion, volume and oxygenation state. We currently are employing the WiFI instrument to study tumor development in a BRCA1/p53 deficient mice breast tumor model. The animals are monitored with WiFI during hyperoxic respiratory challenge. At present, four tumors have been measured with WiFI, and preliminary data suggest that tumor metabolic changes during hyperoxic respiratory challenge can be determined.

  4. Biochemical changes related to hypoxia during cerebral aneurysm surgery: combined microdialysis and tissue oxygen monitoring: case report.

    Science.gov (United States)

    Hutchinson, P J; Al-Rawi, P G; O'Connell, M T; Gupta, A K; Pickard, J D; Kirkpatrick, P J

    2000-01-01

    The objective of this study was to monitor brain metabolism on-line during aneurysm surgery, by combining the use of a multiparameter (brain tissue oxygen, brain carbon dioxide, pH, and temperature) sensor with microdialysis (extracellular glucose, lactate, pyruvate, and glutamate). The case illustrates the potential value of these techniques by demonstrating the effects of adverse physiological events on brain metabolism and the ability to assist in both intraoperative and postoperative decision-making. A 41-year-old woman presented with a World Federation of Neurological Surgeons Grade I subarachnoid hemorrhage. Angiography revealed a basilar artery aneurysm that was not amenable to coiling, so the aneurysm was clipped. Before the craniotomy was performed, a multiparameter sensor and a microdialysis catheter were inserted to monitor brain metabolism. During the operation, the brain oxygen level decreased, in relation to biochemical changes, including the reduction of extracellular glucose and pyruvate and the elevation of lactate and glutamate. These changes were reversible. However, when the craniotomy was closed, a second decrease in brain oxygen occurred in association with brain swelling, which immediately prompted a postoperative computed tomographic scan. The scan demonstrated acute hydrocephalus, requiring external ventricular drainage. The patient made a full recovery. The monitoring techniques influenced clinical decision-making in the treatment of this patient. On-line measurement of brain tissue gases and extracellular chemistry has the potential to assist in the perioperative and postoperative management of patients undergoing complex cerebrovascular surgery and to establish the effects of intervention on brain homeostasis.

  5. Spin polarized electronic states and spin textures at the surface of oxygen-deficient SrTiO3

    Science.gov (United States)

    Jeschke, Harald O.; Altmeyer, Michaela; Rozenberg, Marcelo; Gabay, Marc; Valenti, Roser

    We investigate the electronic structure and spin texture at the (001) surface of SrTiO3 in the presence of oxygen vacancies by means of ab initio density functional theory (DFT) calculations of slabs. Relativistic non-magnetic DFT calculations exhibit Rashba-like spin winding with a characteristic energy scale ~ 10 meV. However, when surface magnetism on the Ti ions is included, bands become spin-split with an energy difference ~ 100 meV at the Γ point. This energy scale is comparable to the observations in SARPES experiments performed on the two-dimensional electronic states confined near the (001) surface of SrTiO3. We find the spin polarized state to be the ground state of the system, and while magnetism tends to suppress the effects of the relativistic Rashba interaction, signatures of it are still clearly visible in terms of complex spin textures. We gratefully acknowledge financial support from the Deutsche Forschungsgemeinschaft through grants SFB/TR 49 and FOR 1346.

  6. The chemical composition of TS 01, the most oxygen-deficient planetary nebula. AGB nucleosynthesis in a metal-poor binary star

    Science.gov (United States)

    Stasińska, G.; Morisset, C.; Tovmassian, G.; Rauch, T.; Richer, M. G.; Peña, M.; Szczerba, R.; Decressin, T.; Charbonnel, C.; Yungelson, L.; Napiwotzki, R.; Simón-Díaz, S.; Jamet, L.

    2010-02-01

    The planetary nebula TS 01 (also called PN G 135.9+55.9 or SBS 1150+599A) with its record-holding low oxygen abundance and its double degenerate close binary core (period 3.9 h) is an exceptional object located in the Galactic halo. We have secured observational data in a complete wavelength range to pin down the abundances of half a dozen elements in the nebula. The abundances are obtained via detailed photoionization modelling which takes into account all the observational constraints (including geometry and aperture effects) using the pseudo-3D photoionization code Cloudy_3D. The spectral energy distribution of the ionizing radiation is taken from appropriate model atmospheres. Incidentally we find from the new observational constraints that both stellar components contribute to the ionization: the “cool” one provides the bulk of hydrogen ionization, while the “hot” one is responsible for the presence of the most highly charged ions, which explains why previous attempts to model the nebula experienced difficulties. The nebular abundances of C, N, O, and Ne are found to be 1/3.5, 1/4.2, 1/70, and 1/11 of the solar value respectively, with uncertainties of a factor 2. Thus the extreme O deficiency of this object is confirmed. The abundances of S and Ar are less than 1/30 of solar. The abundance of He relative to H is 0.089 ± 0.009. Standard models of stellar evolution and nucleosynthesis cannot explain the abundance pattern observed in the nebula. To obtain an extreme oxygen deficiency in a star whose progenitor has an initial mass of about 1 M⊙ requires an additional mixing process, which can be induced by stellar rotation and/or by the presence of the close companion. We have computed a stellar model with an initial mass of 1 M⊙, appropriate metallicity, and initial rotation of 100 km s-1, and find that rotation greatly improves the agreement between the predicted and observed abundances. Based on observations obtained at the Canada

  7. Regional gradients in surface sediment nitrogen isotopes as a reflection of nutrient cycling and oxygen deficiency in upwelling areas off Peru and Namibia (Invited)

    Science.gov (United States)

    Schneider, R. R.; Mollier-Vogel, E.; Martinez, P.

    2010-12-01

    The sedimentary d15N signal is commonly considered as a reflection of the marine nutrient cycling and related biochemical processes in the overlying water masses. In the modern ocean all processes together result in a mean d15N value of about 5 to 6 per mill for dissolved nitrate. Deviations from this value are considered as a product mainly of nitrogen fixation and nitrate supply causing lower values, while nitrate utilization and denitrification, as well as organic matter degradation tend to shift the signal to higher values. As denitrification is only occurring under conditions of strong oxygen limitation in the water column outstandingly high d15N values in sediment records are commonly taken as indirect evidence for strong oxygen minimum conditions in the past. By comparing surface sediment values from coastal upwelling areas off Namibia and Peru, we test whether such an approach is applicable. Only the Peruvian system is characterized by a pronounced oxygen minimum zone (OMZ) that extends across the shelf and slope far into the Eastern Equatorial Pacific. For comparison we present new results for the Peruvian margin between 2°N and 20°S within and below the Peruvian OMZ in combination with a similar data set from the Namibian margin with an OMZ restricted to the inner shelf. The Peruvian sediment data is furthermore compared to d15N of dissolved nitrate in the overlying water column to better understand how regional oceanography effects the water column d15N and thus the sediment surface signal. Productivity and nitrate uptake is maximal at the position of local and perennial upwelling cells in both systems. However, due to continuous nutrient supply into the upwelling systems sedimentary d15N values on the outer shelves and slopes reveal an increase of only about 2 to 3 per mill over the mean ocean value. Only where extreme oxygen deficiency occurs, as off Peru between 10 and 20 S, the sedimentary d15N signal reaches very high values above 10 per mill

  8. Subcutaneous and Intramuscular Hemodynamics and Oxygenation After Cold-Spray Application as Monitored by Near-Infrared Spectroscopy

    Science.gov (United States)

    Shadgan, Babak; Pakravan, Amir H.; Hoens, Alison; Reid, W. Darlene

    2015-01-01

    Context Vapocoolant spray, commonly known as cold spray (CS), is a cryotherapy modality used in sports medicine, athletic training, and rehabilitation settings. Proposed physiologic effects of cryotherapy modalities include reductions in tissue blood flow, oxygenation, and cell metabolism in addition to attenuation of pain perception attributed to reduced superficial nerve conduction velocity. Objective To examine the effects of CS on subcutaneous and intramuscular blood flow and oxygenation on the thigh muscle using near-infrared spectroscopy, an optical method to monitor changes in tissue oxygenated (O2Hb), deoxygenated (HHb), and total (tHb) hemoglobin. Design Cross-sectional study. Setting Muscle Biophysics Laboratory. Patients or Other Participants Participants were 13 healthy adults (8 men, 5 women; age = 37.4 ± 6 years, body mass index = 27.4 ± 2.6, adipose tissue thickness = 7.2 ± 1.8 mm). Intervention(s) Conventional CS was applied to the vastus medialis muscles. Main Outcome Measure(s) Changes in chromophore concentrations of O2Hb, HHb, and tHb at superficial and deep layers were monitored for 5 minutes using a 2-channel near-infrared spectroscopy. Results Thirty seconds after CS application, we observed a decrease from baseline in O2Hb and tHb only in the superficial layer that was maintained for 3 minutes. Conclusions Application of CS induced a transient change in blood flow and oxygenation of the superficial tissues with no change in deeper tissues over the healthy vastus medialis muscle. The limited physiologic effect of CS on the superficial hemodynamics and oxygenation of limb muscles may limit the therapeutic benefit of this cryotherapy modality to a temporary analgesic effect, a hypothesis that warrants a clinical trial on traumatized muscles. PMID:26098273

  9. Magnetic field effects on spectrally resolved lifetime of on-line oxygen monitoring using magneto-optic probes

    Science.gov (United States)

    Mermut, O.; Gallant, P.; Le Bouch, N.; Leclair, S.; Noiseux, I.; Vernon, M.; Morin, J.-F.; Diamond, K.; Patterson, M. S.; Samkoe, K.; Pogue, B.

    2009-02-01

    Multimodal agents that serve as both probes for contrast and light-activated effectors of cellular processes in diseased tissue were developed. These agents were introduced into multicellular tumor spheroids (3D tissue models) and in the chorioallantoic membrane (CAM) of a chicken embryo. The luminescence decay was examined using a novel technique involving a spectrally-resolved fluorescence lifetime apparatus integrated with a weak electromagnet. A spectrallyresolved lifetime setup was used to identify magneto-optic species sensitive to magnetic field effects and distinguish from background emissions. We demonstrate that the applied magnetic fields can alter reaction rates and product distribution of some dyes detected by time- and spectrally-resolved luminescence changes. We will discuss the use of exogenous magneto-optical probes taken up in tumors to both induce phototoxicity, a process that is governed by complex and dynamically evolving mechanisms involving reactive oxygen species, and monitor treatment progress. The magnetic field enhancement, measured over a range of weak fields (0-300 mT) is correlated to oxygenation and may be used to monitor dynamic changes occurring due to oxygen consumption over the course of photodynamic therapy. Such online measurements provide the possibility to derive real-time information about response to treatment via monitoring magnetic field enhancement/suppression of the time-resolved, spectrally-resolved luminescence of the probe at the site of the treatment directly. Magnetic perturbation of lifetime can serve as a status reporter, providing optical feedback of oxygen-mediated treatments in situ and allowing for real-time adjustment of a phototherapy treatment plan.

  10. PHYTOALEXIN DEFICIENT 4 affects reactive oxygen species metabolism, cell wall and wood properties in hybrid aspen (Populus tremula L. × tremuloides).

    Science.gov (United States)

    Ślesak, Ireneusz; Szechyńska-Hebda, Magdalena; Fedak, Halina; Sidoruk, Natalia; Dąbrowska-Bronk, Joanna; Witoń, Damian; Rusaczonek, Anna; Antczak, Andrzej; Drożdżek, Michał; Karpińska, Barbara; Karpiński, Stanisław

    2015-07-01

    The phytoalexin deficient 4 (PAD4) gene in Arabidopsis thaliana (AtPAD4) is involved in the regulation of plant--pathogen interactions. The role of PAD4 in woody plants is not known; therefore, we characterized its function in hybrid aspen and its role in reactive oxygen species (ROS)-dependent signalling and wood development. Three independent transgenic lines with different suppression levels of poplar PAD expression were generated. All these lines displayed deregulated ROS metabolism, which was manifested by an increased H2O2 level in the leaves and shoots, and higher activities of manganese superoxide dismutase (MnSOD) and catalase (CAT) in the leaves in comparison to the wild-type plants. However, no changes in non-photochemical quenching (NPQ) between the transgenic lines and wild type were observed in the leaves. Moreover, changes in the ROS metabolism in the pad4 transgenic lines positively correlated with wood formation. A higher rate of cell division, decreased tracheid average size and numbers, and increased cell wall thickness were observed. The results presented here suggest that the Populus tremula × tremuloides PAD gene might be involved in the regulation of cellular ROS homeostasis and in the cell division--cell death balance that is associated with wood development. © 2014 John Wiley & Sons Ltd.

  11. Artificial oxygen transport protein

    Science.gov (United States)

    Dutton, P. Leslie

    2014-09-30

    This invention provides heme-containing peptides capable of binding molecular oxygen at room temperature. These compounds may be useful in the absorption of molecular oxygen from molecular oxygen-containing atmospheres. Also included in the invention are methods for treating an oxygen transport deficiency in a mammal.

  12. Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Langberg, H; Olesen, J

    2001-01-01

    , brain and connective tissue, and more recently it has been used in the clinical setting to assess circulatory and metabolic abnormalities. Quantitative measures of blood flow are also possible using NIRS and a light-absorbing tracer, which can be applied to evaluate circulatory responses to exercise......Near infrared spectroscopy (NIRS) is becoming a widely used research instrument to measure tissue oxygen (O2) status non-invasively. Continuous-wave spectrometers are the most commonly used devices, which provide semi-quantitative changes in oxygenated and deoxygenated hemoglobin in small blood...... vessels (arterioles, capillaries and venules). Refinement of NIRS hardware and the algorithms used to deconvolute the light absorption signal have improved the resolution and validity of cytochrome oxidase measurements. NIRS has been applied to measure oxygenation in a variety of tissues including muscle...

  13. Update on the use of dissolved oxygen addition to monitor the effectiveness of noble metal applications in external manifolds

    International Nuclear Information System (INIS)

    Varela, J.A.; Huie, H.H.; Seeman, R.A.; Bourne, C.M.; Odell, A.D.

    2014-01-01

    Electrochemical corrosion potential (ECP) measurements in a Mitigation Monitoring System (MMS) ECP manifold have historically been a primary indicator of the effectiveness of an On-Line NobleChem™ (OLNC) application, with the MMS ECP intended to measure the catalytic effect of noble metal deposited on the ECP manifold surface. In some plants ECP measurements made on untreated surfaces prior to an OLNC application were significantly lower than what would be expected for stainless steel under reactor bulk chemistry conditions. This is due to the consumption and depletion of bulk liquid dissolved oxygen (DO) in the lines supplying reactor water to these external ECP measurement locations. This phenomenon degrades the ability to use these external manifolds to confirm noble metal deposition. Previous papers have described how the injection of an oxygen-rich stream to the MMS supply stream (DO Addition) can be used to re-establish the capability of external ECP measurements to monitor the catalytic behavior of platinum deposited during an OLNC injection. This paper will provide an update of how this method is being successfully used in operating BWRs to monitor OLNC injections. The paper will outline the overall approach used to characterize the catalytic behavior of external ECP manifolds before and after the noble metal application and present plant data collected during DO Additions performed under various conditions. (author)

  14. Iron deficiency in childhood

    NARCIS (Netherlands)

    Uijterschout, L.

    2015-01-01

    Iron deficiency (ID) is the most common micronutrient deficiency in the world. Iron is involved in oxygen transport, energy metabolism, immune response, and plays an important role in brain development. In infancy, ID is associated with adverse effects on cognitive, motor, and behavioral development

  15. Electrocatalytic oxygen reduction and hydrogen evolution reactions on phthalocyanine modified electrodes: Electrochemical, in situ spectroelectrochemical, and in situ electrocolorimetric monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Koca, Atif, E-mail: akoca@eng.marmara.edu.tr [Department of Chemical Engineering, Faculty of Engineering, Marmara University, Goeztepe, 34722 Istanbul (Turkey); Kalkan, Ayfer; Bayir, Zehra Altuntas [Department of Chemistry, Technical University of Istanbul, Maslak, 34469 Istanbul (Turkey)

    2011-06-30

    Highlights: > Electrochemical and in situ spectroelectrochemical characterizations of the metallophthalocyanines were performed. > The presence of O{sub 2} influences both oxygen reduction reaction and the electrochemical behaviors of the complexes. > Homogeneous catalytic ORR process occurs via an 'inner sphere' chemical catalysis process. > CoPc and CuPc coated on a glassy carbon electrode decrease the overpotential of the working electrode for H{sup +} reduction. - Abstract: This study describes electrochemical, in situ spectroelectrochemical, and in situ electrocolorimetric monitoring of the electrocatalytic reduction of molecular oxygen and hydronium ion on the phthalocyanine-modified electrodes. For this purpose, electrochemical and in situ spectroelectrochemical characterizations of the metallophthalocyanines (MPc) bearing tetrakis-[4-((4'-trifluoromethyl)phenoxy)phenoxy] groups were performed. While CoPc gives both metal-based and ring-based redox processes, H{sub 2}Pc, ZnPc and CuPc show only ring-based electron transfer processes. In situ electrocolorimetric method was applied to investigate the color of the electrogenerated anionic and cationic forms of the complexes. The presence of O{sub 2} in the electrolyte system influences both oxygen reduction reaction and the electrochemical and spectral behaviors of the complexes, which indicate electrocatalytic activity of the complexes for the oxygen reduction reaction. Perchloric acid titrations monitored by voltammetry represent possible electrocatalytic activities of the complexes for hydrogen evolution reaction. CoPc and CuPc coated on a glassy carbon electrode decrease the overpotential of the working electrode for H{sup +} reduction. The nature of the metal center changes the electrocatalytic activities for hydrogen evolution reaction in aqueous solution. Although CuPc has an inactive metal center, its electrocatalytic activity is recorded more than CoPc for H{sup +} reduction in aqueous

  16. Enhanced Reactive Oxygen Species Production, Acidic Cytosolic pH and Upregulated Na+/H+ Exchanger (NHE) in Dicer Deficient CD4+ T Cells.

    Science.gov (United States)

    Singh, Yogesh; Zhou, Yuetao; Zhang, Shaqiu; Abdelazeem, Khalid N M; Elvira, Bernat; Salker, Madhuri S; Lang, Florian

    2017-01-01

    MicroRNAs (miRNAs) negatively regulate gene expression at a post-transcriptional level. Dicer, a cytoplasmic RNase III enzyme, is required for the maturation of miRNAs from precursor miRNAs. Dicer, therefore, is a critical enzyme involved in the biogenesis and processing of miRNAs. Several biological processes are controlled by miRNAs, including the regulation of T cell development and function. T cells generate reactive oxygen species (ROS) with parallel H+ extrusion accomplished by the Na+/H+-exchanger 1 (NHE1). The present study explored whether ROS production, as well as NHE1 expression and function are sensitive to the lack of Dicer (miRNAs deficient) and could be modified by individual miRNAs. CD4+ T cells were isolated from CD4 specific Dicer deficient (DicerΔ/Δ) mice and the respective control mice (Dicerfl/fl). Transcript and protein levels were quantified with RT-PCR and Western blotting, respectively. For determination of intracellular pH (pHi) cells were incubated with the pH sensitive dye bis-(2-carboxyethyl)-5-(and-6)-carboxyfluorescein (BCECF) and Na+/H+ exchanger (NHE) activity was calculated from re-alkalinization after an ammonium pulse. Changes in cell volume were measured using the forward scatter in flow cytometry, and ROS production utilizing 2',7' -dichlorofluorescin diacetate (DCFDA) fluorescence. Transfection of miRNA-control and mimics in T cells was performed using DharmaFECT3 reagent. ROS production, cytosolic H+ concentration, NHE1 transcript and protein levels, NHE activity, and cell volume were all significantly higher in CD4+ T cells from DicerΔ/Δ mice than in CD4+ T cells from Dicerfl/fl mice. Furthermore, individual miR-200b and miR-15b modify pHi and NHE activity in Dicerfl/fl and DicerΔ/Δ CD4+ T cells, respectively. Lack of Dicer leads to oxidative stress, cytosolic acidification, upregulated NHE1 expression and activity as well as swelling of CD4+ T cells, functions all reversed by miR-15b or miR-200b. © 2017 The Author

  17. Monitoring the oxygenation of the preterm brain : What is there to gain?

    NARCIS (Netherlands)

    Alderliesten, T.

    2016-01-01

    Despite advances in perinatal care, preterm birth is still associated with adverse neurodevelopmental outcome, often caused by cerebral injury. The most common forms of cerebral injury are all associated with disturbances in cerebral oxygen and blood supply. Traditionally, infant wellbeing is

  18. Storage Pool Deficiencies

    Science.gov (United States)

    ... Deficiency Factor V Deficiency Combined FV & FVIII Deficiencies Factor VII Deficiency Factor X Deficiency Factor XI Deficiency Factor ... Deficiency Factor V Deficiency Combined FV & FVIII Deficiencies Factor VII Deficiency Factor X Deficiency Factor XI Deficiency Factor ...

  19. Reactive Oxygen Species-Mediated Loss of Synaptic Akt1 Signaling Leads to Deficient Activity-Dependent Protein Translation Early in Alzheimer's Disease.

    Science.gov (United States)

    Ahmad, Faraz; Singh, Kunal; Das, Debajyoti; Gowaikar, Ruturaj; Shaw, Eisha; Ramachandran, Arathy; Rupanagudi, Khader Valli; Kommaddi, Reddy Peera; Bennett, David A; Ravindranath, Vijayalakshmi

    2017-12-01

    Synaptic deficits are known to underlie the cognitive dysfunction seen in Alzheimer's disease (AD). Generation of reactive oxygen species (ROS) by β-amyloid has also been implicated in AD pathogenesis. However, it is unclear whether ROS contributes to synaptic dysfunction seen in AD pathogenesis and, therefore, we examined whether altered redox signaling could contribute to synaptic deficits in AD. Activity dependent but not basal translation was impaired in synaptoneurosomes from 1-month old presymptomatic APP Swe /PS1ΔE9 (APP/PS1) mice, and this deficit was sustained till middle age (MA, 9-10 months). ROS generation leads to oxidative modification of Akt1 in the synapse and consequent reduction in Akt1-mechanistic target of rapamycin (mTOR) signaling, leading to deficiency in activity-dependent protein translation. Moreover, we found a similar loss of activity-dependent protein translation in synaptoneurosomes from postmortem AD brains. Loss of activity-dependent protein translation occurs presymptomatically early in the pathogenesis of AD. This is caused by ROS-mediated loss of pAkt1, leading to reduced synaptic Akt1-mTOR signaling and is rescued by overexpression of Akt1. ROS-mediated damage is restricted to the synaptosomes, indicating selectivity. We demonstrate that ROS-mediated oxidative modification of Akt1 contributes to synaptic dysfunction in AD, seen as loss of activity-dependent protein translation that is essential for synaptic plasticity and maintenance. Therapeutic strategies promoting Akt1-mTOR signaling at synapses may provide novel target(s) for disease-modifying therapy in AD. Antioxid. Redox Signal. 27, 1269-1280.

  20. ABOUT A CHOICE OF MATHEMATICAL MODELS OF KINETICS OF CULTIVATION OF SACCHAROMYCES CEREVISIAE YEAST IN THE CONDITIONS OF DEFICIENCY OF OXYGEN

    Directory of Open Access Journals (Sweden)

    V. B. Tishin

    2015-01-01

    Full Text Available Summary. In the production technology of many foods microbiological processes are crucial to the economic indicators of enterprises and the quality of the products manufactured. The examples of this are the production, where the biomass is the end product. For example, the production of various strains of the yeast Saccharomyces for different branches of the food industry: baking, brewing, winemaking, as well as for the pharmaceutical industry. The development of mathematical models of microbial cells is one of the greatest challenges of microbiology. The need to search for mathematical models is dictated by the continuous development of microbiological industry, increases in the requirements for the production design, maintenance and predictions of the processes depending on the change of process parameters. However, this requires knowledge of the laws governing material and energy exchange between the culture medium and the cell and the availability of mathematical models describing them. This knowledge cannot be obtained without studying the biological processes kinetics. Kinetic regularities of microbial growth is largely determined by the selection method of the microbiological process and the type of equipment in which these processes occur. Many biological processes can be described with a simple mathematical model, but there are kinetic regularities of biological processes that can only be described by equations of more complex type. Culturing yeast kinetic models, reflecting the complexity of the biological processes occurring during the cultivation were obtained. According to the analysis of experimental data on the Saccharomyces cerevisiae yeast culturing with a batch process, a system of equations (mathematical model, giving a functional relationship of biomass growth and cells consumption of carbohydrates with their different initial values in a culture medium under conditions of oxygen deficiency without stirring is obtained.

  1. Noninvasive Optical Monitoring of Spinal Cord Hemodynamics and Oxygenation after Acute Spinal Cord Injury

    Science.gov (United States)

    2017-09-01

    model in anesthetized (immobile) animals. Task 1: Evaluating the NIRS system function in a pig model of SCI in conjunction with IP measurements...started. We are collecting spinal cord NIRS data, using the V1 and OXT5 NIRS systems, in conjunction with IP measurements of spinal cord tissue...model of SCI in conjunction with IP measurements of oxygen, perfusion, pressure, and metabolism. SC150178 Kwon - Anual Report – Sep 01 2016 – Aug 31

  2. Met-myoglobin formation, accumulation, degradation, and myoglobin oxygenation monitoring based on multiwavelength attenuance measurement in porcine meat

    Science.gov (United States)

    Nguyen, Thien; Phan, Kien Nguyen; Lee, Jee-Bum; Kim, Jae Gwan

    2016-05-01

    We propose a simple, rapid, and nondestructive method to investigate formation, accumulation, and degradation of met-myoglobin (met-Mb) and myoglobin oxygenation from the interior of porcine meat. For the experiment, color photos and attenuance spectra of porcine meat (well-bled muscle, fat, and mixed) were collected daily to perform colorimetric analysis and to obtain the differences of attenuance between 578 and 567 nm (A578-A567) and between 615 and 630 nm (A630-A615), respectively. Oxy-, deoxy-, and met-myoglobin concentration changes over storage time were also calculated using Beer-Lamberts' law with reflectance intensities at 557, 582, and 630 nm. The change of A578-A567 was well matched with the change of myoglobin oxygenation, and the change of A630-A615 corresponded well with the formation and degradation of met-Mb. In addition, attenuation differences, A578-A567 and A630-A615, were able to show the formation of met-Mb earlier than colorimetric analysis. Therefore, the attenuance differences between wavelengths can be indicators for estimating myoglobin oxygenation and met-Mb formation, accumulation, and degradation, which enable us to design a simple device to monitor myoglobin activities in porcine meat.

  3. Animal studies using an oxygen-tension sensor for tissue viability monitoring

    NARCIS (Netherlands)

    Tanase, D.; Komen, N.; Draaijer, A.; Lange, J.F.; Kleinrensink, G.J.; Jeekel, J.; French, P.J.

    2008-01-01

    Leakage at the site of an anastomosis is the main, yet unsolved reason for mortality in abdominal surgery. Every year, a large number of patients die due to anastomotic leakage after surgery. An objective aid to monitor the anastomotic site pre- and postoperatively and detect leakage at an early

  4. Journal of Clinical Monitoring and Computing 2015 end of year summary : tissue oxygenation and microcirculation

    NARCIS (Netherlands)

    Scheeren, T W L

    Last year we started this series of end of year summaries of papers published in the 2014 issues of the Journal Of Clinical Monitoring And Computing with a review on near infrared spectroscopy (Scheeren et al. in J Clin Monit Comput 29(2):217-220, 2015). This year we will broaden the scope and

  5. Multiple approaches for enhancing all-organic electronics photoluminescent sensors: Simultaneous oxygen and pH monitoring

    International Nuclear Information System (INIS)

    Liu, Rui; Xiao, Teng; Cui, Weipan; Shinar, Joseph; Shinar, Ruth

    2013-01-01

    Graphical abstract: -- Highlights: •Novel simply-fabricated all-organic electronics pH and oxygen optical monitor. •Excitation sources: directionally emitting, narrowed multicolor microcavity OLEDs. •Photodetectors: small molecule- or polymer-based with selective spectral responses. •Sensor film: structured high molecular weight polystyrene:polyethylene glycol blend. •×1.9 sensitivity enhancement and ×2.7 increase in the photoluminescence for oxygen. -- Abstract: Key issues in using organic light emitting diodes (OLEDs) as excitation sources in structurally integrated photoluminescence (PL)-based sensors are the low forward light outcoupling, the OLEDs’ broad electroluminescence (EL) bands, and the long-lived remnant EL that follows an EL pulse. The outcoupling issue limits the detection sensitivity (S) as only ∼20% of the light generated within standard OLEDs can be forward outcoupled and used for sensor probe excitation. The EL broad band interferes with the analyte-sensitive PL, leading to a background that reduces S and dynamic range. In particular, these issues hinder designing compact sensors, potentially miniaturizable, that are devoid of optical filters and couplers. We address these shortcomings by introducing easy-to-employ multiple approaches for outcoupling improvement, PL enhancement, and background EL reduction leading to novel, compact all-organic device architectures demonstrated for simultaneous monitoring of oxygen and pH. The sensor comprises simply-fabricated, directionally-emitting, narrower-band, multicolor microcavity OLED excitation and small molecule- and polymer-based organic photodetectors (OPDs) with a more selective spectral response. Additionally, S and PL intensity for oxygen are enhanced by using polystyrene (PS):polyethylene glycol (PEG) blends as the sensing film matrix. By utilizing higher molecular weight PS, the ratio τ 0 /τ 100 (PL decay time τ at 0% O 2 /τ at 100% O 2 ) that is often used to express S

  6. Cerebral oxygenation in contusioned vs. nonlesioned brain tissue: monitoring of PtiO2 with Licox and Paratrend.

    Science.gov (United States)

    Sarrafzadeh, A S; Kiening, K L; Bardt, T F; Schneider, G H; Unterberg, A W; Lanksch, W R

    1998-01-01

    Brain tissue PO2 in severely head injured patients was monitored in parallel with two different PO2-microsensors (Licox and Paratrend). Three different locations of sensor placement were chosen: (1) both catheters into non lesioned tissue (n = 3), (2) both catheters into contusioned tissue (n = 2), and (3) one catheter (Licox) into pericontusional versus one catheter (Paratrend) into non lesioned brain tissue (n = 2). Mean duration of PtiO2-monitoring with both microsensors in parallel was 68.1 hours. Brain tissue PO2 varied when measured in lesioned and nonlesioned tissue. In non lesioned tissue both catheters closely correlated (delta Licox/Paratrend: mean PtiO2 delta lesioned/non lesioned: mean PtiO2: 10.3 mm Hg). In contusioned brain tissue PtiO2 was always below the "hypoxic threshold" of 10 mm Hg, independent of the type of microsensor used. During a critical reduction in cerebral perfusion pressure (PO2, only increased PtiO2 when measured in pericontusional and nonlesioned brain. To recognize critical episodes of hypoxia or ischemia, PtiO2-monitoring of cerebral oxygenation is recommended in nonlesioned brain tissue.

  7. Corrosion of copper in oxygen-deficient groundwater with and without deep bedrock micro-organisms: Characterisation of microbial communities and surface processes

    Energy Technology Data Exchange (ETDEWEB)

    Huttunen-Saarivirta, E., E-mail: elina.huttunen-saarivirta@vtt.fi [VTT Technical Research Centre of Finland, Materials Performance, Kemistintie 3, FI-02044 VTT (Finland); Rajala, P. [VTT Technical Research Centre of Finland, Materials Performance, Kemistintie 3, FI-02044 VTT (Finland); Bomberg, M. [VTT Technical Research Centre of Finland, Geobiotechnology, Tietotie 2, FI-02044 VTT (Finland); Carpén, L. [VTT Technical Research Centre of Finland, Materials Performance, Kemistintie 3, FI-02044 VTT (Finland)

    2017-02-28

    Highlights: • Copper was exposed to groundwater with and without deep bedrock micro-organisms. • Biofilm composition was determined and correlated with the behaviour of copper. • Under biotic conditions, the film of Cu{sub 2}S formed on copper surfaces. • Bacterial pool was in a key role for the morphology and properties of Cu{sub 2}S film. • Under abiotic conditions, Cu{sub 2}O systematically developed on copper surfaces. - Abstract: Copper specimens were exposed to oxygen-deficient artificial groundwater in the presence and absence of micro-organisms enriched from the deep bedrock of the planned nuclear waste repository site at Olkiluoto island on the western coast of Finland. During the exposure periods of 4 and 10 months, the copper specimens were subjected to electrochemical measurements. The biofilm developed on the specimens and the water used in the exposures were subjected to microbiological analyses. Changes in the water chemistry were also determined and surfaces of the copper specimens were characterized with respect to the morphology and composition of the formed corrosion products. The results showed that under biotic conditions, redox of the water and open circuit potential (OCP) of the copper specimens were generally negative and resulted in the build-up of a copper sulphide, Cu{sub 2}S, layer due to the activity of sulphate-reducing bacteria (SRB) that were included in the system. In the 4-month test, the electrochemical behaviour of the specimens changed during the exposure and alphaproteobactria Rhizobiales were the dominant bacterial group in the biofilm where the highest corrosion rate was observed. In the 10-month test, however, deltaproteobacteria SRB flourished and the initial electrochemical behaviour and the low corrosion rate of the copper were retained until the end of the test period. Under abiotic conditions, the positive water redox potential and specimen OCP correlated with the formation of copper oxide, Cu{sub 2}O

  8. Corrosion of copper in oxygen-deficient groundwater with and without deep bedrock micro-organisms: Characterisation of microbial communities and surface processes

    International Nuclear Information System (INIS)

    Huttunen-Saarivirta, E.; Rajala, P.; Bomberg, M.; Carpén, L.

    2017-01-01

    Highlights: • Copper was exposed to groundwater with and without deep bedrock micro-organisms. • Biofilm composition was determined and correlated with the behaviour of copper. • Under biotic conditions, the film of Cu_2S formed on copper surfaces. • Bacterial pool was in a key role for the morphology and properties of Cu_2S film. • Under abiotic conditions, Cu_2O systematically developed on copper surfaces. - Abstract: Copper specimens were exposed to oxygen-deficient artificial groundwater in the presence and absence of micro-organisms enriched from the deep bedrock of the planned nuclear waste repository site at Olkiluoto island on the western coast of Finland. During the exposure periods of 4 and 10 months, the copper specimens were subjected to electrochemical measurements. The biofilm developed on the specimens and the water used in the exposures were subjected to microbiological analyses. Changes in the water chemistry were also determined and surfaces of the copper specimens were characterized with respect to the morphology and composition of the formed corrosion products. The results showed that under biotic conditions, redox of the water and open circuit potential (OCP) of the copper specimens were generally negative and resulted in the build-up of a copper sulphide, Cu_2S, layer due to the activity of sulphate-reducing bacteria (SRB) that were included in the system. In the 4-month test, the electrochemical behaviour of the specimens changed during the exposure and alphaproteobactria Rhizobiales were the dominant bacterial group in the biofilm where the highest corrosion rate was observed. In the 10-month test, however, deltaproteobacteria SRB flourished and the initial electrochemical behaviour and the low corrosion rate of the copper were retained until the end of the test period. Under abiotic conditions, the positive water redox potential and specimen OCP correlated with the formation of copper oxide, Cu_2O. Furthermore, in the absence of

  9. Influence of the depth of sedation on regional cerebral oxygen saturation monitoring in neurosurgery of supratentorial gliomas

    Directory of Open Access Journals (Sweden)

    ZHANG Kai⁃ying

    2012-12-01

    Full Text Available Objective To investigate the influence on regional cerebral oxygen saturation (rScO2 of sedation depth during anesthesia induction and maintenance in supratentorial glioma resections. Methods Thirty patients with Ⅰ - Ⅱ supratentorial glioma (graded by American Society of Anesthesiologists underwent elective supratentorial glioma resection were included in this study. Rocuronium, sufentanil and propofol were used for anesthesia induction. After trachea cannula, total intravenous anesthesia (TIVA was maintained with plasma concentration of propofol 2.80-3.20 μg/ml and remifentanil 0.10-0.20 μg/(kg·min. Thirty groups of rScO2, bispectral index (BIS, mean arterial pressure (MAP and heart rate (HR were recorded continuously till the incision. Results During anesthesia induction, BIS decreased along with the infusion of anesthetics, and there was significant negative correlation between BIS and rScO2 (r = ⁃0.803, P = 0.001. During anesthesia maintenance, rScO2 and BIS were not significantly related (r = 0.147, P = 0.396. Conclusion The rScO2 monitoring can reflect the influence of sedation depth on cerebral oxygen delivery and consumption balance during supratentorial glioma resection under TIVA.

  10. Extreme dissolved oxygen variability in urbanised tropical wetlands: The need for detailed monitoring to protect nursery ground values

    Science.gov (United States)

    Dubuc, Alexia; Waltham, Nathan; Malerba, Martino; Sheaves, Marcus

    2017-11-01

    Little is known about levels of dissolved oxygen fish are exposed to daily in typical urbanised tropical wetlands found along the Great Barrier Reef coastline. This study investigates diel dissolved oxygen (DO) dynamics in one of these typical urbanised wetlands, in tropical North Queensland, Australia. High frequency data loggers (DO, temperature, depth) were deployed for several days over the summer months in different tidal pools and channels that fish use as temporal or permanent refuges. DO was extremely variable over a 24 h cycle, and across the small-scale wetland. The high spatial and temporal DO variability measured was affected by time of day and tidal factors, namely water depth, tidal range and tidal direction (flood vs ebb). For the duration of the logging time, DO was mainly above the adopted threshold for hypoxia (50% saturation), however, for around 11% of the time, and on almost every logging day, DO values fell below the threshold, including a severe hypoxic event (nursery ground value. There is a substantial discontinuity between the recommended DO values in the Australian and New Zealand Guidelines for Fresh and Marine Water Quality and the values observed in this wetland, highlighting the limited value of these guidelines for management purposes. Local and regional high frequency data monitoring programs, in conjunction with local exposure risk studies are needed to underpin the development of the management that will ensure the sustainability of coastal wetlands.

  11. Implementing an Oxygen Supplementation and Monitoring Protocol on Inpatient Pediatric Bronchiolitis: An Exercise in Deimplementation

    Directory of Open Access Journals (Sweden)

    Brian LeCleir

    2017-01-01

    Full Text Available Aim. Our goal in this study is to evaluate the effectiveness of our oxygen (O2 protocol to reduce length of stay (LOS for children hospitalized with bronchiolitis. Methods. In this retrospective cohort study, the outcomes of children ≤ 24 months old that were admitted with bronchiolitis and placed on the O2 protocol were compared to historical controls. The primary outcome was hospital length of stay. Secondary outcomes were duration of O2 supplementation, rates of pediatric intensive care unit transfer, and readmission. Results. Groups were not significantly different in age, gender, and rates of respiratory distress score assessment. Significantly more severely ill patients were in the O2 protocol group. There were no significant differences between control and O2 protocol groups with regard to mean LOS, rates of pediatric intensive care unit transfer, or seven-day readmission rates. By multiple regression analysis, the use of the O2 protocol was associated with a nearly 20% significant decrease in the length of hospitalization (p=0.030. Conclusion. Use of O2 supplementation protocol increased LOS in the more ill patients with bronchiolitis but decreased overall LOS by having a profound effect on patients with mild bronchiolitis.

  12. Electrochemical monitoring of native catalase activity in skin using skin covered oxygen electrode.

    Science.gov (United States)

    Nocchi, Sarah; Björklund, Sebastian; Svensson, Birgitta; Engblom, Johan; Ruzgas, Tautgirdas

    2017-07-15

    A skin covered oxygen electrode, SCOE, was constructed with the aim to study the enzyme catalase, which is part of the biological antioxidative system present in skin. The electrode was exposed to different concentrations of H 2 O 2 and the amperometric current response was recorded. The observed current is due to H 2 O 2 penetration through the outermost skin barrier (referred to as the stratum corneum, SC) and subsequent catalytic generation of O 2 by catalase present in the underlying viable epidermis and dermis. By tape-stripping the outermost skin layers we demonstrate that SC is a considerable diffusion barrier for H 2 O 2 penetration. Our experiments also indicate that skin contains a substantial amount of catalase, which is sufficient to detoxify H 2 O 2 that reaches the viable epidermis after exposure of skin to high concentrations of peroxide (0.5-1mM H 2 O 2 ). Further, we demonstrate that the catalase activity is reduced at acidic pH, as compared with the activity at pH 7.4. Finally, experiments with often used penetration enhancer thymol shows that this compound interferes with the catalase reaction. Health aspect of this is briefly discussed. Summarizing, the results of this work show that the SCOE can be utilized to study a broad spectrum of issues involving the function of skin catalase in particular, and the native biological antioxidative system in skin in general. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Towards real-time non contact spatial resolved oxygenation monitoring using a multi spectral filter array camera in various light conditions

    Science.gov (United States)

    Bauer, Jacob R.; van Beekum, Karlijn; Klaessens, John; Noordmans, Herke Jan; Boer, Christa; Hardeberg, Jon Y.; Verdaasdonk, Rudolf M.

    2018-02-01

    Non contact spatial resolved oxygenation measurements remain an open challenge in the biomedical field and non contact patient monitoring. Although point measurements are the clinical standard till this day, regional differences in the oxygenation will improve the quality and safety of care. Recent developments in spectral imaging resulted in spectral filter array cameras (SFA). These provide the means to acquire spatial spectral videos in real-time and allow a spatial approach to spectroscopy. In this study, the performance of a 25 channel near infrared SFA camera was studied to obtain spatial oxygenation maps of hands during an occlusion of the left upper arm in 7 healthy volunteers. For comparison a clinical oxygenation monitoring system, INVOS, was used as a reference. In case of the NIRS SFA camera, oxygenation curves were derived from 2-3 wavelength bands with a custom made fast analysis software using a basic algorithm. Dynamic oxygenation changes were determined with the NIR SFA camera and INVOS system at different regional locations of the occluded versus non-occluded hands and showed to be in good agreement. To increase the signal to noise ratio, algorithm and image acquisition were optimised. The measurement were robust to different illumination conditions with NIR light sources. This study shows that imaging of relative oxygenation changes over larger body areas is potentially possible in real time.

  14. Imprint and oxygen deficiency in (Pb,La)(Zr,Ti)O3 thin-film capacitors with La-Sr-Co-O electrodes

    International Nuclear Information System (INIS)

    Lee, J.; Ramesh, R.; Keramidas, V.G.; Warren, W.L.; Pike, G.E.; Evans, J.T. Jr.

    1995-01-01

    La-Sr-Co-O/Pb-La-Zr-Ti-O/La-Sr-Co-O thin-film capacitors have been grown in various oxygen ambients by pulsed laser deposition. As the oxygen ambient became more reducing, the capacitors developed more voltage asymmetry in hysteresis loops and a more preferred polarization state directed towards the top electrode. PLZT capacitors cooled in a fully oxidizing atmosphere (i.e., 1 atm oxygen pressure) exhibited nominally symmetric hysteresis loops and also showed little imprint both with and without fully saturating bias fields. We find that ambient oxygen pressure is an important process parameter and the imprint behavior is closely related with ambient oxygen induced effects such as oxygen vacancies, its related defect-dipole complexes and trapping of free charges. The different imprint behavior under negative and positive bias also suggests that the dipolar-defect complexes tend to cause imprint in PLZT capacitors

  15. The potential of biosensor technology in clinical monitoring and experimental research

    NARCIS (Netherlands)

    Leegsma-Vogt, G; Rhemrev-Boom, MM; Tiessen, RG; Venema, K; Korf, J

    2004-01-01

    Glucose or lactate biosensors are very useful for monitoring metabolism. Continuous monitoring of glucose is for example very important in diabetic patients. The measurement of lactate, a marker for oxygen deficiency, is used in the intensive care unit to monitor the patients' condition. In our

  16. Integration of intracellular telomerase monitoring by electrochemiluminescence technology and targeted cancer therapy by reactive oxygen species.

    Science.gov (United States)

    Zhang, Huairong; Li, Binxiao; Sun, Zhaomei; Zhou, Hong; Zhang, Shusheng

    2017-12-01

    Cancer therapies based on reactive oxygen species (ROS) have emerged as promising clinical treatments. Electrochemiluminescence (ECL) technology has also attracted considerable attention in the field of clinical diagnosis. However, studies about the integration of ECL diagnosis and ROS cancer therapy are very rare. Here we introduce a novel strategy that employs ECL technology and ROS to fill the above vacancy. Briefly, an ITO electrode was electrodeposited with polyluminol-Pt NPs composite films and modified with aptamer DNA to capture HL-60 cancer cells with high specificity. After that, mesoporous silica nanoparticles (MSNs) filled with phorbol 12-myristate 13-acetate (PMA) were closed by the telomerase primer DNA (T-primer DNA) and aptamer. After aptamer on MSN@PMA recognized and combined with the HL-60 cancer cells with high specificity, T-primer DNA on MSN@PMA could be moved away from the MSN@PMA surface after extension by telomerase in the HL-60 cancer cells and PMA was released to induce the production of ROS by the HL-60 cancer cells. After that, the polyluminol-Pt NPs composite films could react with hydrogen peroxide (a major ROS) and generate an ECL signal. Thus the intracellular telomerase activity of the HL-60 cancer cells could be detected in situ . Besides, ROS could induce apoptosis in the HL-60 cancer cells with high efficacy by causing oxidative damage to the lipids, protein, and DNA. Above all, the designed platform could not only detect intracellular telomerase activity instead of that of extracted telomerase, but could also kill targeted tumors by ECL technology and ROS.

  17. Can systemically generated reactive oxygen species help to monitor disease activity in generalized vitiligo? A pilot study

    Directory of Open Access Journals (Sweden)

    Richeek Pradhan

    2014-01-01

    Full Text Available Background: Generalized vitiligo is a disease with unpredictable bursts of activity, goal of treatment during the active phase being to stabilize the lesions. This emphasizes the need for a prospective marker for monitoring disease activity to help decide the duration of therapy. Aims and Objectives: In the present study, we examined whether reactive oxygen species (ROS generated in erythrocytes can be translated into a marker of activity in vitiligo. Materials and Methods: Level of intracellular ROS was measured flow cytometrically in erythrocytes from venous blood of 21 patients with generalized vitiligo and 21 healthy volunteers using the probe dichlorodihydrofluorescein diacetate. Results: The levels of ROS differed significantly between patients and healthy controls, as well as between active versus stable disease groups. In the active disease group, ROS levels were significantly lower in those being treated with systemic steroids than those that were not. ROS levels poorly correlated with disease duration or body surface area involved. Conclusion: A long-term study based on these findings can be conducted to further validate the potential role of ROS in monitoring disease activity vitiligo.

  18. Monitoring of the Gasoline Oxygenate MTBE and BTEX Compounds in Groundwater in Catalonia (Northeast Spain

    Directory of Open Access Journals (Sweden)

    J. Fraile

    2002-01-01

    Full Text Available Headspace (HS gas chromatography with flame ionisation detection (HS-GC-FID and purge and trap (P gas chromatography-mass spectrometry (P were used for the determination of methyl-tert-butyl ether (MTBE and benzene, toluene, and xylenes (BTEX in groundwater. In this work, we present the first data on the levels of MTBE and BTEX in different groundwater wells in the area of Catalonia (northeast Spain. This monitoring campaign corresponded to 28 groundwater wells that were located near petrol service stations, oil refinery storage tanks, and/or chemical industry at different locations of Catalonia during the period of 1998/1999. The levels of MTBE detected varied between 4—300 μg/l, but two sites had MTBE levels up to 3 and 13 mg/l. In many cases, the BTEX levels were below 1 μg/l, whereas 7 sites had levels varying from 19 μg/l up to 3 mg/l. Most of them were related to leakage from underground tanks in petrol service stations, while the remaining three corresponded respectively to chemical industrial pollution of undetermined origin and to a leak from high-ground petrol tanks in petrochemical refinery factories. The aquifers involved were constituted by detritus coarse materials, sands, and conglomerates. Piezometric levels were roughly comprised between 3 and 40 m, and permeability (K and transmissivity (T values were estimated from field measurements.

  19. Multiple approaches for enhancing all-organic electronics photoluminescent sensors: Simultaneous oxygen and pH monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Rui; Xiao, Teng; Cui, Weipan [Ames Laboratory-USDOE and Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Shinar, Joseph, E-mail: jshinar@iastate.edu [Ames Laboratory-USDOE and Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Shinar, Ruth, E-mail: rshinar@iastate.edu [Microelectronics Research Center and Department of Electrical and Computer Engineering, Iowa State University, Ames, IA 50011 (United States)

    2013-05-17

    Graphical abstract: -- Highlights: •Novel simply-fabricated all-organic electronics pH and oxygen optical monitor. •Excitation sources: directionally emitting, narrowed multicolor microcavity OLEDs. •Photodetectors: small molecule- or polymer-based with selective spectral responses. •Sensor film: structured high molecular weight polystyrene:polyethylene glycol blend. •×1.9 sensitivity enhancement and ×2.7 increase in the photoluminescence for oxygen. -- Abstract: Key issues in using organic light emitting diodes (OLEDs) as excitation sources in structurally integrated photoluminescence (PL)-based sensors are the low forward light outcoupling, the OLEDs’ broad electroluminescence (EL) bands, and the long-lived remnant EL that follows an EL pulse. The outcoupling issue limits the detection sensitivity (S) as only ∼20% of the light generated within standard OLEDs can be forward outcoupled and used for sensor probe excitation. The EL broad band interferes with the analyte-sensitive PL, leading to a background that reduces S and dynamic range. In particular, these issues hinder designing compact sensors, potentially miniaturizable, that are devoid of optical filters and couplers. We address these shortcomings by introducing easy-to-employ multiple approaches for outcoupling improvement, PL enhancement, and background EL reduction leading to novel, compact all-organic device architectures demonstrated for simultaneous monitoring of oxygen and pH. The sensor comprises simply-fabricated, directionally-emitting, narrower-band, multicolor microcavity OLED excitation and small molecule- and polymer-based organic photodetectors (OPDs) with a more selective spectral response. Additionally, S and PL intensity for oxygen are enhanced by using polystyrene (PS):polyethylene glycol (PEG) blends as the sensing film matrix. By utilizing higher molecular weight PS, the ratio τ{sub 0}/τ{sub 100} (PL decay time τ at 0% O{sub 2}/τ at 100% O{sub 2}) that is often used

  20. Monitoring in microvascular tissue transfer by measurement of oxygen partial pressure: four years experience with 125 microsurgical transplants.

    Science.gov (United States)

    Jonas, René; Schaal, Thomas; Krimmel, Michael; Gülicher, Dirk; Reinert, Siegmar; Hoffmann, Jürgen

    2013-06-01

    In a prospective study, the characteristics and benefit of an invasive measurement of oxygen partial pressure (pO(2)) with the aid of a polarographic sensor were investigated in 125 microsurgical reconstructions of the head and neck area over a period of 45 months. Measurements were performed over 96 h in eight different types of microsurgically revascularized flaps for extra- and intraoral reconstructions and were evaluated separately for each flap type. Of 125 reconstructions the system indicated malperfusion in 18 cases. Salvage surgery was performed in 17 cases due to venous thrombosis (6 cases), arterial thrombosis (3 cases), a combination of arterial and venous thrombosis (2 cases), rheological problems (3 cases), venous insufficiency by hematoma (2 cases) and kinking of vessels (1 case). In 10 cases salvage surgery was successful, 7 flaps were lost despite salvage surgery. In all these cases, the polarographic probe indicated the necessity of salvage surgery correctly. After 96 h no malperfusion was seen. Postoperatively, a common and characteristic development of the oxygen partial pressure in different types of flaps was seen. Initially, a clear increase of pO(2) could be measured. During 96 h, a slow decrease of pO(2) was observed. In conclusion polarographic measurement of pO(2) can be an excellent apparative supplement for the postoperative clinical control of microsurgically revascularized transplants. In buried flaps, this technique represents the only reliable method for transplant monitoring. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Magnetoresistance Versus Oxygen Deficiency in Epi-stabilized SrRu1 - x Fe x O3 - δ Thin Films.

    Science.gov (United States)

    Dash, Umasankar; Acharya, Susant Kumar; Lee, Bo Wha; Jung, Chang Uk

    2017-12-01

    Oxygen vacancies have a profound effect on the magnetic, electronic, and transport properties of transition metal oxide materials. Here, we studied the influence of oxygen vacancies on the magnetoresistance (MR) properties of SrRu 1 - x Fe x O 3 - δ epitaxial thin films (x = 0.10, 0.20, and 0.30). For this purpose, we synthesized highly strained epitaxial SrRu 1 - x Fe x O 3 - δ thin films with atomically flat surfaces containing different amounts of oxygen vacancies using pulsed laser deposition. Without an applied magnetic field, the films with x = 0.10 and 0.20 showed a metal-insulator transition, while the x = 0.30 thin film showed insulating behavior over the entire temperature range of 2-300 K. Both Fe doping and the concentration of oxygen vacancies had large effects on the negative MR contributions. For the low Fe doping case of x = 0.10, in which both films exhibited metallic behavior, MR was more prominent in the film with fewer oxygen vacancies or equivalently a more metallic film. For semiconducting films, higher MR was observed for more semiconducting films having more oxygen vacancies. A relatively large negative MR (~36.4%) was observed for the x = 0.30 thin film with a high concentration of oxygen vacancies (δ = 0.12). The obtained results were compared with MR studies for a polycrystal of (Sr 1 - x La x )(Ru 1 - x Fe x )O 3 . These results highlight the crucial role of oxygen stoichiometry in determining the magneto-transport properties in SrRu 1 - x Fe x O 3 - δ thin films.

  2. Detection and Characterization of Reactive Oxygen and Nitrogen Species in Biological Systems by Monitoring Species-Specific Products.

    Science.gov (United States)

    Hardy, Micael; Zielonka, Jacek; Karoui, Hakim; Sikora, Adam; Michalski, Radosław; Podsiadły, Radosław; Lopez, Marcos; Vasquez-Vivar, Jeannette; Kalyanaraman, Balaraman; Ouari, Olivier

    2018-05-20

    Since the discovery of the superoxide dismutase enzyme, the generation and fate of short-lived oxidizing, nitrosating, nitrating, and halogenating species in biological systems has been of great interest. Despite the significance of reactive oxygen species (ROS) and reactive nitrogen species (RNS) in numerous diseases and intracellular signaling, the rigorous detection of ROS and RNS has remained a challenge. Recent Advances: Chemical characterization of the reactions of selected ROS and RNS with electron paramagnetic resonance (EPR) spin traps and fluorescent probes led to the establishment of species-specific products, which can be used for specific detection of several forms of ROS and RNS in cell-free systems and in cultured cells in vitro and in animals in vivo. Profiling oxidation products from the ROS and RNS probes provides a rigorous method for detection of those species in biological systems. Formation and detection of species-specific products from the probes enables accurate characterization of the oxidative environment in cells. Measurement of the total signal (fluorescence, chemiluminescence, etc.) intensity does not allow for identification of the ROS/RNS formed. It is critical to identify the products formed by using chromatographic or other rigorous techniques. Product analyses should be accompanied by monitoring of the intracellular probe level, another factor controlling the yield of the product(s) formed. More work is required to characterize the chemical reactivity of the ROS/RNS probes, and to develop new probes/detection approaches enabling real-time, selective monitoring of the specific products formed from the probes. Antioxid. Redox Signal. 28, 1416-1432.

  3. Iodine Deficiency

    Science.gov (United States)

    ... Fax/Phone Home » Iodine Deficiency Leer en Español Iodine Deficiency Iodine is an element that is needed ... world’s population remains at risk for iodine deficiency. Iodine Deficiency FAQs WHAT IS THE THYROID GLAND? The ...

  4. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Complications Undiagnosed or untreated iron-deficiency anemia may cause the following complications: Depression Heart problems. If you do not have enough hemoglobin-carrying red blood cells, your heart has to work harder to move oxygen-rich blood through your ...

  5. Multiple approaches for enhancing all-organic electronics photoluminescent sensors: simultaneous oxygen and pH monitoring.

    Science.gov (United States)

    Liu, Rui; Xiao, Teng; Cui, Weipan; Shinar, Joseph; Shinar, Ruth

    2013-05-17

    Key issues in using organic light emitting diodes (OLEDs) as excitation sources in structurally integrated photoluminescence (PL)-based sensors are the low forward light outcoupling, the OLEDs' broad electroluminescence (EL) bands, and the long-lived remnant EL that follows an EL pulse. The outcoupling issue limits the detection sensitivity (S) as only ~20% of the light generated within standard OLEDs can be forward outcoupled and used for sensor probe excitation. The EL broad band interferes with the analyte-sensitive PL, leading to a background that reduces S and dynamic range. In particular, these issues hinder designing compact sensors, potentially miniaturizable, that are devoid of optical filters and couplers. We address these shortcomings by introducing easy-to-employ multiple approaches for outcoupling improvement, PL enhancement, and background EL reduction leading to novel, compact all-organic device architectures demonstrated for simultaneous monitoring of oxygen and pH. The sensor comprises simply-fabricated, directionally-emitting, narrower-band, multicolor microcavity OLED excitation and small molecule- and polymer-based organic photodetectors (OPDs) with a more selective spectral response. Additionally, S and PL intensity for oxygen are enhanced by using polystyrene (PS):polyethylene glycol (PEG) blends as the sensing film matrix. By utilizing higher molecular weight PS, the ratio τ0/τ100 (PL decay time τ at 0% O2/τ at 100% O2) that is often used to express S increases ×1.9 to 20.7 relative to the lower molecular weight PS, where this ratio is 11.0. This increase reduces to ×1.7 when the PEG is added (τ0/τ100=18.2), but the latter results in an increase ×2.7 in the PL intensity. The sensor's response time is <10s in all cases. The microporous structure of these blended films, with PEG decorating PS pores, serves a dual purpose. It results in light scattering that reduces the EL that is waveguided in the substrate of the OLEDs and

  6. The oxygen deficient Ruddlesden-Popper La3Ni2O7-δ (δ = 0.65) phase: Structure and properties

    International Nuclear Information System (INIS)

    Poltavets, Viktor V.; Lokshin, Konstantin A.; Egami, Takeshi; Greenblatt, Martha

    2006-01-01

    La 3 Ni 2 O 7-δ (δ = 0.65) was synthesized by hydrogen reduction of the parent La 3 Ni 2 O 7 Ruddlesden-Popper nickelate. The crystal structure of La 3 Ni 2 O 6.35 (space group: I4/mmm, a = 3.8742 (1) A and c = 20.055 (1) A) has been determined from powder neutron diffraction data by the Rietveld method for the first time. The oxygen vacancies are located in the LaO x planes between two of the NiO 2 layers. Removal of these oxygen atoms from the parent phase results in a significant (∼0.4 A) shrinkage of the perovskite block along c-direction and splitting of the Ni position. The major part of Ni cations is surrounded by five oxygen atoms forming square pyramids, while the rest are coordinated to six octahedrally arranged oxygen atoms. Over the 170-400 K temperature range, the conductivity of La 3 Ni 2 O 6.35 follows Mott's variable range hopping model modified for a 2D case

  7. Near-Bed Monitoring of Suspended Sediment during a Major Flood Event Highlights Deficiencies in Existing Event-Loading Estimates

    Directory of Open Access Journals (Sweden)

    Alistair Grinham

    2018-01-01

    Full Text Available Rates of fluvial sediment discharge are notoriously difficult to quantify, particularly during major flood events. Measurements are typically undertaken using event stations requiring large capital investment, and the high cost tends to reduce the spatial coverage of monitoring sites. This study aimed to characterise the near-bed suspended sediment dynamics during a major flood event using a low-cost approach. Monitoring nodes consisted of a total suspended sediment (TSS logger, a single stage sampler, and a time-lapse camera for a total cost of less than US$420. Seven nodes were deployed across an elevation gradient on the stream bank of Laidley Creek, Queensland, Australia, and two of these nodes successfully characterised the near-bed suspended sediment dynamics across a major flood event. Near-bed TSS concentrations were closely related to stream flow, with the contribution of suspended bed material dominating the total suspended load during peak flows. Observed TSS concentrations were orders of magnitude higher than historical monitoring data for this site collected using the State government event station. This difference was attributed to the event station pump inlet screening the suspended bed material prior to sample collection. The ‘first flush’ phenomenon was detected and attributed to a local resuspension of muddy crusts immediately upstream of the study site. This low-cost approach will provide an important addition to the existing monitoring of fluvial sediment discharge during flood events.

  8. Direct observation of hopping induced spin polarization current in oxygen deficient Co-doped ZnO by Andreev reflection technique

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kung-Shang; Huang, Tzu-Yu; Dwivedi, G.D. [Department of Physics, National Sun Yat-sen University, Kaohsiung, Taiwan (China); Lin, Lu-Kuei; Lee, Shang-Fan [Taiwan Institute of Physics, Academia Sinica, Taipei, Taiwan (China); Sun, Shih-Jye [Department of Applied Physics, National Kaohsiung University, Kaohsiung, Taiwan (China); Chou, Hsiung, E-mail: hchou@mail.nsysu.edu.tw [Department of Physics, National Sun Yat-sen University, Kaohsiung, Taiwan (China)

    2017-07-01

    Highlights: • Co-doped ZnO thin-films were grown with varying V{sub O} concentartion. • PCAR measurements were done to study the SPC. • High spin polarization was observed above a certain V{sub O} concentartion. • High V{sub O} samples provide a high density of completed percolation path. • This complete percolation path gives rise to high SPC. - Abstract: Oxygen vacancy induced ferromagnetic coupling in diluted magnetic oxide (DMO) semiconductors have been reported in several studies, but technologically more crucial spin-polarized current (SPC) is still under-developed in DMOs. Few studies have claimed that VRH mechanism can originate the SPC, but, how VRH mechanism associated with percolation path, is not clearly understood. We used Point-contact Andreev reflection (PCAR) technique to probe the SPC in Co-doped ZnO (CZO) films. Since the high resistance samples cause broadening in conductance(G)-voltage(V) curves, which may result in an unreliable evaluation of spin polarization, we include two extra parameters, (i) effective temperature and (ii) spreading resistance, for the simulation to avoid the uncertainty in extracting spin polarization. The effective G-V curves and higher spin polarization can be obtained above a certain oxygen vacancy concentration. The number of completed and fragmentary percolation paths is proportional to the concentration of oxygen vacancies. For low oxygen vacancy samples, the Pb-tip has a higher probability of covering fragmentary percolation paths than the complete ones, due to its small contact size. The completed paths may remain independent of one another and get polarized in different directions, resulting in lower spin-polarization value. High oxygen vacancy samples provide a high density of completed path, most of them link to one another by crossing over, and gives rise to high spin-polarization value.

  9. Control and monitoring of oxygen content in molten metals. Application to lead and lead-bismuth melts

    International Nuclear Information System (INIS)

    Ghetta, V.; Fouletier, J.; Henault, M.; Le Moulec, A.

    2002-01-01

    The sources of error in potentiometric measurements of the oxygen activity in molten metals and the methods proposed to reduce these measurements errors are described. Specific constraints related to low temperature measurements are emphasized. Two set-ups for control of the oxygen activity in molten lead and lead-bismuth were developed. They involve zirconia-based cells, i.e., an oxygen pump and an oxygen probe. The performance of the set-ups was characterized attempts to reduce the working temperature (T<450 deg C) are discussed. (authors)

  10. Manganese deficiency in plants

    DEFF Research Database (Denmark)

    Schmidt, Sidsel Birkelund; Jensen, Poul Erik; Husted, Søren

    2016-01-01

    Manganese (Mn) is an essential plant micronutrient with an indispensable function as a catalyst in the oxygen-evolving complex (OEC) of photosystem II (PSII). Even so, Mn deficiency frequently occurs without visual leaf symptoms, thereby masking the distribution and dimension of the problem...... restricting crop productivity in many places of the world. Hence, timely alleviation of latent Mn deficiency is a challenge in promoting plant growth and quality. We describe here the key mechanisms of Mn deficiency in plants by focusing on the impact of Mn on PSII stability and functionality. We also address...... the mechanisms underlying the differential tolerance towards Mn deficiency observed among plant genotypes, which enable Mn-efficient plants to grow on marginal land with poor Mn availability....

  11. Replacement of chemical oxygen demand (COD) with total organic carbon (TOC) for monitoring wastewater treatment performance to minimize disposal of toxic analytical waste.

    Science.gov (United States)

    Dubber, Donata; Gray, Nicholas F

    2010-10-01

    Chemical oxygen demand (COD) is widely used for wastewater monitoring, design, modeling and plant operational analysis. However this method results in the production of hazardous wastes including mercury and hexavalent chromium. The study examined the replacement of COD with total organic carbon (TOC) for general performance monitoring by comparing their relationship with influent and effluent samples from 11 wastewater treatment plants. Biochemical oxygen demand (BOD5) was also included in the comparison as a control. The results show significant linear relationships between TOC, COD and BOD5 in settled (influent) domestic and municipal wastewaters, but only between COD and TOC in treated effluents. The study concludes that TOC can be reliably used for the generic replacement of both COD (COD=49.2+3.00*TOC) and BOD5 (BOD5=23.7+1.68*TOC) in influent wastewaters but only for COD (COD=7.25+2.99*TOC) in final effluents.

  12. Study and development of a fluorescence based sensor system for monitoring oxygen in wine production : the WOW project

    NARCIS (Netherlands)

    Trivellin, Nicola; Barbisan, Diego; Badocco, Denis; Pastore, Paolo; Meneghesso, Gaudenzio; Meneghini, Matteo; Zanoni, Enrico; Belgioioso, Giuseppe; Cenedese, Angelo

    2018-01-01

    The importance of oxygen in the winemaking process is widely known, as it affects the chemical aspects and therefore the organoleptic characteristics of the final product. Hence, it is evident the usefulness of a continuous and real-time measurements of the levels of oxygen in the various stages of

  13. The performance of spinel bulk-like oxygen-deficient CoGa2O4 as an air-cathode catalyst in microbial fuel cell

    Science.gov (United States)

    Liu, Di; Mo, Xiaoping; Li, Kexun; Liu, Yi; Wang, Junjie; Yang, Tingting

    2017-08-01

    Nano spinel bulk-like CoGa2O4 prepared via a facile hydrothermal method is used as a high efficient electrochemical catalyst in activated carbon (AC) air-cathode microbial fuel cell (MFC). The maximum power density of the modified MFC is 1911 ± 49 mW m-2, 147% higher than the MFC of untreated AC cathode. Transmission electron microscope (TEM) and X-ray diffraction (XRD) exhibit the morphology and crystal structure of CoGa2O4. Rotating disk electrode (RDE) confirms the four-electron pathway at the cathode during the oxygen reduction reaction (ORR). Thermogravimetric analysis (TGA) and X-ray photoelectron spectroscopy (XPS) illustrate that the high rate oxygen vacancy exist in the CoGa2O4. The oxygen vacancy of CoGa2O4 plays an important role in catalytic activity. In a word, the prepared nano spinel bulk-like CoGa2O4 provides an alternative to the costly Pt in air-cathode for power output.

  14. Health Deficiencies

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of all health deficiencies currently listed on Nursing Home Compare, including the nursing home that received the deficiency, the associated inspection date,...

  15. Observation of the strain-driven charge-ordered state in La sub 0 sub . sub 7 sub C a sub 0 sub . sub 3 MnO sub 3 sub - sub d elta thin film with oxygen deficiency

    CERN Document Server

    Prokhorov, V G; Kaminsky, G G; Svetchnikov, V L; Zandbergen, H W; Lee, Y P; Park, J S; Kim, K W

    2003-01-01

    The magnetic and transport properties of La sub 0 sub . sub 7 Ca sub 0 sub . sub 3 MnO sub 3 sub - sub d elta films with an oxygen deficiency (delta approx 0.1) and a La sub 0 sub . sub 9 Ca sub 0 sub . sub 1 MnO sub 3 film with the stoichiometric oxygen content are investigated in a wide temperature range. It is shown that the charge-ordered insulating (COI) state is observed for a La sub 0 sub . sub 7 Ca sub 0 sub . sub 3 MnO sub 2 sub . sub 9 film with thickness d <= 30 nm, which manifests mainly a cubic crystal structure with an anomalously small lattice parameter for this composition. An increase in the film thickness (d approx 60 nm) leads to a structural transition from the lattice-strained cubic to the relaxed rhombohedral phase, is accompanied by a shift of the Curie point (T sub C) to lower temperature and a frustration of the COI state. The magnetic and transport properties of the La sub 0 sub . sub 7 Ca sub 0 sub . sub 3 MnO sub 2 sub . sub 9 film with d approx 60 nm are similar to those exhibi...

  16. Monitoring hemodynamics and oxygenation of the kidney in rats by a combined near-infrared spectroscopy and invasive probe approach

    Science.gov (United States)

    Grosenick, Dirk; Cantow, Kathleen; Arakelyan, Karen; Wabnitz, Heidrun; Flemming, Bert; Skalweit, Angela; Ladwig, Mechthild; Macdonald, Rainer; Niendorf, Thoralf; Seeliger, Erdmann

    2015-07-01

    We have developed a hybrid approach to investigate the dynamics of perfusion and oxygenation in the kidney of rats under pathophysiologically relevant conditions. Our approach combines near-infrared spectroscopy to quantify hemoglobin concentration and oxygen saturation in the renal cortex, and an invasive probe method for measuring total renal blood flow by an ultrasonic probe, perfusion by laser-Doppler fluxmetry, and tissue oxygen tension via fluorescence quenching. Hemoglobin concentration and oxygen saturation were determined from experimental data by a Monte Carlo model. The hybrid approach was applied to investigate and compare temporal changes during several types of interventions such as arterial and venous occlusions, as well as hyperoxia, hypoxia and hypercapnia induced by different mixtures of the inspired gas. The approach was also applied to study the effects of the x-ray contrast medium iodixanol on the kidney.

  17. The limitations of tissue-oxygen measurement and positron emission tomography as additional methods for postoperative breast reconstruction free-flap monitoring.

    Science.gov (United States)

    Schrey, Aleksi; Niemi, Tarja; Kinnunen, Ilpo; Minn, Heikki; Vahlberg, Tero; Kalliokoski, Kari; Suominen, Erkki; Grénman, Reidar; Aitasalo, Kalle

    2010-02-01

    Twelve patients who underwent breast reconstruction with a microvascular flap were monitored postoperatively with continuous partial tissue oxygenation (p(ti)O(2)) measurement. The regional blood flow (BF) of the entire flap was evaluated with positron emission tomography (PET) using oxygen-15-labelled water on the first postoperative (POP) morning to achieve data of the perfusion of the entire flap. A re-exploration was carried out if the p(ti)O(2) value remained lower than 15 mmHg for over 30 min. The mean p(ti)O(2) value of the flaps was 52.9+/-5.5 mmHg, whereas the mean BF values were 3.3+/-1.0 ml per 100 g min(-1). One false-positive result was detected by p(ti)O(2) measurement, resulting in an unnecessary re-exploration. Another re-operation suggested by the low p(ti)O(2) results was avoided due to the normal BF results assessed with PET. Totally, three flaps were re-explored. This prospective study suggests that continuous tissue-oxygen measurement with a polarographic needle probe is reliable for monitoring free breast flaps from one part of the flap, but assessing perfusion of the entire flap requires more complex monitoring methods, for example, PET. Clinical examination by experienced personnel remains important in free-breast-flap monitoring. PET could be useful in assessing free-flap perfusion in selected high-risk patients as an alternative to a re-operation when clinical examination and evaluation by other means are unreliable or present controversial results. 2008 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Anesthesia for arthroscopic shoulder surgery in the beach chair position: monitoring of cerebral oxygenation using combined bispectral index and near-infrared spectroscopy.

    Science.gov (United States)

    Kawano, Hiroaki; Matsumoto, Tomomi

    2014-10-01

    Recent research has shown that cerebrovascular complications following shoulder surgery performed in the beach chair position under general anesthesia arise secondary to cerebral ischemia. Appropriate management of cerebral oxygenation is thus one of the primary goals of anesthetic management during such procedures. The present report describes the case of a 65-year-old male patient, in which both bispectral index (BIS) and near-infrared spectroscopy (NIRS) were used to monitor cerebral oxygenation. During the positioning, we observed an increased suppression ratio (SR) while BIS and regional cerebral oxygen saturation (rSO2) were at adequate level. In view of the difference in blood pressure between the heart and the base of the brain, blood pressure was maintained to ensure adequate cerebral perfusion. Although intraoperative rSO2 was at or around the cut-off point (a 12% relative decrease from baseline), no marked decrease in BIS or further increase in the SR was observed. Monitoring of cerebral perfusion using combined BIS and NIRS optimized anesthetic management during the performance of arthroscopic shoulder surgery in the beach chair position.

  19. Real-time monitoring of luminescent lifetime changes of PtOEP oxygen sensing film with LED/photodiode-based time-domain lifetime device.

    Science.gov (United States)

    Ji, Shaomin; Wu, Wanhua; Wu, Yubo; Zhao, Taiyang; Zhou, Fuke; Yang, Yubin; Zhang, Xin; Liang, Xiaofen; Wu, Wenting; Chi, Lina; Wang, Zhonggang; Zhao, Jianzhang

    2009-05-01

    A cost-effective LED/photodiode(PD)-based time-domain luminescent lifetime measuring device with rugged electronics and simplified algorithms was assembled and successfully used to characterize oxygen sensing films, by continuously monitoring phosphorescence lifetime changes of phosphorescent platinum octaethylporphyrin (PtOEP) in cardo poly(aryl ether ketone) polymer (IMPEK-C) vs. variation of the oxygen partial pressure in a gas mixture (O(2)/N(2)). The results determined by both phosphorescence lifetime and intensity monitoring were compared and the lifetime mode gave results which are in good agreement with the intensity mode. The lifetime-based linear Stern-Volmer plot indicates that the PtOEP molecules are nearly homogeneously distributed in the sensing film. The phosphorescent lifetime of the PtOEP film changes from 75 micros in neat N(2) to less than 2 micros in neat O(2). The sensing system (by combination of the PtOEP sensing film with the home-assembled lifetime device) gives a high lifetime-based O(2) sensing resolution, e.g. about 2 micros Torr(-1) for low O(2) concentration (below 3.5% O(2), V/V). This feasible lifetime device configuration is affordable to most sensor laboratories and the device may facilitate the study of O(2) sensing material with the continuous lifetime monitoring method.

  20. Enhancing photocatalytic CO{sub 2} reduction by coating an ultrathin Al{sub 2}O{sub 3} layer on oxygen deficient TiO{sub 2} nanorods through atomic layer deposition

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Huilei; Chen, Jiatang; Rao, Guiying; Deng, Wei; Li, Ying, E-mail: yingli@tamu.edu

    2017-05-15

    Highlights: • Oxygen deficient TiO{sub 2} anatase nanorods are coated with an ultrathin Al{sub 2}O{sub 3} layer by ALD. • Exposed {100} facets and oxygen vacancies promote CO{sub 2} photoreduction to CO and CH{sub 4}. • Al{sub 2}O{sub 3} overlayer passivates surface states and mitigates surface charge recombination. • Two cycles of ALD coating lead to maximum photocatalytic CO{sub 2} reduction. • More than five cycles of ALD coating prohibits electron transfer to the surface. - Abstract: In this work, anatase nanorods (ANR) of TiO{sub 2} with active facet {100} as the major facet were successfully synthesized, and reducing the ANR by NaBH{sub 4} led to the formation of gray colored oxygen deficient TiO{sub 2-x} (ReANR). On the surface of ReANR, a thin layer of Al{sub 2}O{sub 3} was deposited using atomic layer deposition (ALD), and the thickness of Al{sub 2}O{sub 3} varied by the number of ALD cycles (1, 2, 5, 10, 50, 100, or 200). The growth rate of Al{sub 2}O{sub 3} was determined to be 0.25 Å per cycle based on high-resolution TEM analysis, and the XRD result showed the amorphous structure of Al{sub 2}O{sub 3}. All the synthesized photocatalysts (ANR, ReANR, and Al{sub 2}O{sub 3} coated ReANR) were tested for CO{sub 2} photocatalytic reduction in the presence of water vapor, with CO detected as the major reduction product and CH{sub 4} as the minor product. Compared with ANR, ReANR had more than 50% higher CO production and more than ten times higher CH{sub 4} production due to the oxygen vacancies that possibly enhanced CO{sub 2} adsorption and activation. By applying less than 5 cycles of ALD, the Al{sub 2}O{sub 3} coated ReANR had enhanced overall production of CO and CH{sub 4} than uncoated ReANR, with 2 cycles being the optimum, about 40% higher overall production than ReANR. Whereas, both CO and CH{sub 4} production decreased with increasing number of ALD cycles when more than 5 cycles were applied. Photoluminescence (PL) analysis showed an

  1. Iodine Deficiency

    NARCIS (Netherlands)

    Zimmermann, M.B.

    2009-01-01

    Iodine deficiency has multiple adverse effects in humans, termed iodine deficiency disorders, due to inadequate thyroid hormone production. Globally, it is estimated that 2 billion individuals have an insufficient iodine intake, and South Asia and sub-Saharan Africa are particularly affected.

  2. Effects of reactive oxygen species on metabolism monitored by longitudinal 1H single voxel MRS follow-up in patients with mitochondrial disease or cerebral tumors

    International Nuclear Information System (INIS)

    Constans, J M; Collet, S; Hossu, G; Courtheoux, P; Guillamo, J S; Lechapt-Zalcman, E; Valable, S; Lacombe, S; Houee Levin, C; Gauduel, Y A; Dou, W; Ruan, S; Barre, L; Rioult, F; Derlon, J M; Chapon, F; Fong, V; Kauffmann, F

    2011-01-01

    Free radicals, or Reactive Oxygen Species (ROS), have an effect on energy and glycolytic metabolism, mitochondrial function, lipid metabolism, necrosis and apoptosis, cell proliferation, and infiltration. These changes could be monitored longitudinally (every 4 months over 6 years) in humans with glial brain tumors (low and high grade) after therapy, using conventional magnetic resonance imaging (MRI) and spectroscopy (MRS) and MR perfusion. Some examples of early clinical data from longitudinal follow-up monitoring in humans of energy and glycolytic metabolism, lipid metabolism, necrosis, proliferation, and infiltration measured by conventional MRI, MRS and perfusion, and positron emission tomography (PET) are shown in glial brain tumors after therapy. Despite the difficulty, the variability and unknown factors, these repeated measurements give us a better insight into the nature of the different processes, tumor progression and therapeutic response.

  3. Effects of reactive oxygen species on metabolism monitored by longitudinal {sup 1}H single voxel MRS follow-up in patients with mitochondrial disease or cerebral tumors

    Energy Technology Data Exchange (ETDEWEB)

    Constans, J M; Collet, S; Hossu, G; Courtheoux, P [MRI Unit, Caen University Hospital, Caen, Normandy (France); Guillamo, J S; Lechapt-Zalcman, E; Valable, S [CERVOxy Group, CI-NAPS, UMR 6232 CI-NAPS, Cyceron, Caen, Normandy (France); Lacombe, S; Houee Levin, C [Paris-Sud 11 University-CNRS, Orsay (France); Gauduel, Y A [LOA, Ecole Polytechnique - ENSTA ParisTech, Palaiseau (France); Dou, W [Tsinghua University, Beijing (China); Ruan, S [CReSTIC EA 3804, IUT Troyes, Troyes (France); Barre, L [GDMTEP, Group CI-NAPS, UMR 6232 CI-NAPS, Cyceron, Caen (France); Rioult, F [CNRS UMR 6072, GREYC, Caen, Normandy (France); Derlon, J M [Neurosurgery and Neurology, Caen University Hospital, Caen, Normandy (France); Chapon, F [Pathology, Caen University Hospital, Caen, Normandy (France); Fong, V [Caen University (France); Kauffmann, F, E-mail: constans-jm@chu-caen.fr [Mathematics LMNO CNRS UMR 6139, Caen University, Caen, Normandy (France)

    2011-01-01

    Free radicals, or Reactive Oxygen Species (ROS), have an effect on energy and glycolytic metabolism, mitochondrial function, lipid metabolism, necrosis and apoptosis, cell proliferation, and infiltration. These changes could be monitored longitudinally (every 4 months over 6 years) in humans with glial brain tumors (low and high grade) after therapy, using conventional magnetic resonance imaging (MRI) and spectroscopy (MRS) and MR perfusion. Some examples of early clinical data from longitudinal follow-up monitoring in humans of energy and glycolytic metabolism, lipid metabolism, necrosis, proliferation, and infiltration measured by conventional MRI, MRS and perfusion, and positron emission tomography (PET) are shown in glial brain tumors after therapy. Despite the difficulty, the variability and unknown factors, these repeated measurements give us a better insight into the nature of the different processes, tumor progression and therapeutic response.

  4. Combination of On-line pH and Oxygen Transfer Rate Measurement in Shake Flasks by Fiber Optical Technique and Respiration Activity MOnitoring System (RAMOS

    Directory of Open Access Journals (Sweden)

    Jochen Büchs

    2007-12-01

    Full Text Available Shake flasks are commonly used for process development in biotechnologyindustry. For this purpose a lot of information is required from the growth conditions duringthe fermentation experiments. Therefore, Anderlei et al. developed the RAMOS technology[1, 2], which proviedes on-line oxygen and carbondioxide transfer rates in shake flasks.Besides oxygen consumption, the pH in the medium also plays an important role for thesuccessful cultivation of micro-organisms and for process development. For online pHmeasurement fiber optical methods based on fluorophores are available. Here a combinationof the on-line Oxygen Transfer Rate (OTR measurements in the RAMOS device with anon-line, fiber optical pH measurement is presented. To demonstrate the application of thecombined measurement techniques, Escherichia coli cultivations were performed and on-line pH measurements were compared with off-line samples. The combination of on-lineOTR and pH measurements gives a lot of information about the cultivation and, therefore, itis a powerful technique for monitoring shake flask experiments as well as for processdevelopment.

  5. The importance of bilateral monitoring of cerebral oxygenation (NIRS): Clinical case of asymmetry during cardiopulmonary bypass secondary to previous cerebral infarction.

    Science.gov (United States)

    Matcan, S; Sanabria Carretero, P; Gómez Rojo, M; Castro Parga, L; Reinoso-Barbero, F

    2018-03-01

    Cerebral oximetry based on near infrared spectroscopy (NIRS) technology is used to determine cerebral tissue oxygenation. We hereby present the clinical case of a 12-month old child with right hemiparesis secondary to prior left middle cerebral artery stroke 8 months ago. The child underwent surgical enlargement of the right ventricular outflow tract (RVOT) with cardiopulmonary bypass. During cardiopulmonary bypass, asymmetric NIRS results were detected between both hemispheres. The utilization of multimodal neuromonitoring (NIRS-BIS) allowed acting on both perfusion pressure and anesthetic depth to balance out the supply and demand of cerebral oxygen consumption. No new neurological sequelae were observed postoperatively. We consider bilateral NIRS monitoring necessary in order to detect asymmetries between cerebral hemispheres. Although asymmetries were not present at baseline, they can arise intraoperatively and its monitoring thus allows the detection and treatment of cerebral ischemia-hypoxia in the healthy hemisphere, which if undetected and untreated would lead to additional neurological damage. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Biomass characterization by dielectric monitoring of viability and oxygen uptake rate measurements in a novel membrane bioreactor.

    Science.gov (United States)

    Shariati, Farshid Pajoum; Heran, Marc; Sarrafzadeh, Mohammad Hossein; Mehrnia, Mohammad Reza; Sarzana, Gabriele; Ghommidh, Charles; Grasmick, Alain

    2013-07-01

    The application of permittivity and oxygen uptake rate (OUR) as biological process control parameters in a wastewater treatment system was evaluated. Experiments were carried out in a novel airlift oxidation ditch membrane bioreactor under different organic loading rates (OLR). Permittivity as representative of activated sludge viability was measured by a capacitive on-line sensor. OUR was also measured as a representative for respirometric activity. Results showed that the biomass concentration increases with OLR and all biomass related measurements and simulators such as MLSS, permittivity, OUR, ASM1 and ASM3 almost follow the same increasing trends. The viability of biomass decreased when the OLR was reduced from 5 to 4 kg COD m(-3)d(-1). During decreasing of OLR, biomass related parameters generally decreased but not in a similar manner. Also, protein concentration in the system during OLR decreasing changed inversely with the activated sludge viability. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Flame-Oxidized Stainless-Steel Anode as a Probe in Bioelectrochemical System-Based Biosensors to Monitor the Biochemical Oxygen Demand of Wastewater

    Directory of Open Access Journals (Sweden)

    Qiaochu Liang

    2018-02-01

    Full Text Available Biochemical oxygen demand (BOD is a widely used index of water quality in wastewater treatment; however, conventional measurement methods are time-consuming. In this study, we analyzed a novel flame-oxidized stainless steel anode (FO-SSA for use as the probe of bioelectrochemical system (BES-based biosensors to monitor the BOD of treated swine wastewater. A thinner biofilm formed on the FO-SSA compared with that on a common carbon-cloth anode (CCA. The FO-SSA was superior to the CCA in terms of rapid sensing; the response time of the FO-SSA to obtain the value of R2 > 0.8 was 1 h, whereas the CCA required 4 h. These results indicate that the FO-SSA offers better performance than traditional CCAs in BES biosensors and can be used to improve biomonitoring of wastewater.

  8. Monitoring Oxygen Levels in Orthotopic Human Glioma Xenograft Following Carbogen Inhalation and Chemotherapy by Implantable Resonator Based Oximetry

    Science.gov (United States)

    Hou, Huagang; Nemani, Venkata Krishnamurthy; Du, Gaixin; Montano, Ryan; Song, Rui; Gimi, Barjor; Swartz, Harold M.; Eastman, Alan; Khan, Nadeem

    2014-01-01

    Hypoxia is a critical hallmark of glioma, and significantly compromises treatment efficacy. Unfortunately, techniques for monitoring glioma pO2 to facilitate translational research are lacking. Furthermore, poor prognoses of patients with malignant glioma, in particular glioblastoma multiforme, warrant effective strategies that can inhibit hypoxia and improve treatment outcome. EPR oximetry using implantable resonators was implemented for monitoring pO2 in normal cerebral tissue and U251 glioma in mice. Breathing carbogen (95% O2 + 5% CO2) was tested for hyperoxia in the normal brain and glioma xenografts. A new strategy to inhibit glioma growth by rationally combining gemcitabine and MK-8776, a cell cycle checkpoint inhibitor, was also investigated. The mean pO2 of left and right hemisphere were approximately 56 – 69 mmHg in the normal cerebral tissue of mice. The mean baseline pO2 of U251 glioma on the first and fifth day of measurement was 21.9 ± 3.7 and 14.1 ± 2.4 mmHg, respectively. The mean brain pO2 including glioma increased by at least 100% on carbogen inhalation, although the response varied between the animals over days. Treatment with gemcitabine + MK-8776 significantly increased pO2 and inhibited glioma growth assessed by MRI. In conclusion, EPR oximetry with implantable resonators can be used to monitor the efficacy of carbogen inhalation and chemotherapy on orthotopic glioma in mice. The increase in glioma pO2 of mice breathing carbogen can be used to improve treatment outcome. The treatment with gemcitabine + MK-8776 is a promising strategy that warrants further investigation. PMID:25111969

  9. Monitoring oxygen levels in orthotopic human glioma xenograft following carbogen inhalation and chemotherapy by implantable resonator-based oximetry.

    Science.gov (United States)

    Hou, Huagang; Krishnamurthy Nemani, Venkata; Du, Gaixin; Montano, Ryan; Song, Rui; Gimi, Barjor; Swartz, Harold M; Eastman, Alan; Khan, Nadeem

    2015-04-01

    Hypoxia is a critical hallmark of glioma, and significantly compromises treatment efficacy. Unfortunately, techniques for monitoring glioma pO2 to facilitate translational research are lacking. Furthermore, poor prognosis of patients with malignant glioma, in particular glioblastoma multiforme, warrant effective strategies that can inhibit hypoxia and improve treatment outcome. EPR oximetry using implantable resonators was implemented for monitoring pO2 in normal cerebral tissue and U251 glioma in mice. Breathing carbogen (95% O2 + 5% CO2 ) was tested for hyperoxia in the normal brain and glioma xenografts. A new strategy to inhibit glioma growth by rationally combining gemcitabine and MK-8776, a cell cycle checkpoint inhibitor, was also investigated. The mean pO2 of left and right hemisphere were ∼56-69 mmHg in the normal cerebral tissue of mice. The mean baseline pO2 of U251 glioma on the first and fifth day of measurement was 21.9 ± 3.7 and 14.1 ± 2.4 mmHg, respectively. The mean brain pO2 including glioma increased by at least 100% on carbogen inhalation, although the response varied between the animals over days. Treatment with gemcitabine + MK-8776 significantly increased pO2 and inhibited glioma growth assessed by MRI. In conclusion, EPR oximetry with implantable resonators can be used to monitor the efficacy of carbogen inhalation and chemotherapy on orthotopic glioma in mice. The increase in glioma pO2 of mice breathing carbogen can be used to improve treatment outcome. The treatment with gemcitabine + MK-8776 is a promising strategy that warrants further investigation. © 2014 UICC.

  10. A simple and rapid method for monitoring dissolved oxygen in water with a submersible microbial fuel cell (SBMFC)

    DEFF Research Database (Denmark)

    Zhang, Yifeng; Angelidaki, Irini

    2012-01-01

    Asubmersiblemicrobial fuel cell (SBMFC) was developed as a biosensor forin situand real time monitoring of dissolvedoxygen (DO) in environmental waters. Domestic wastewater was utilized as sole fuel for powering the sensor. The sensor performance was firstly examined with tap water at varying DO...... the sensing activities. The sensor ability was further explored under different environmental conditions (e.g., pH, temperature, conductivity, alternative electron acceptor), and the results indicated that a calibration would be required before field application. Lastly, the sensor was tested with different...

  11. Oxygen deficiency in the North Indian Ocean

    Digital Repository Service at National Institute of Oceanography (India)

    Naqvi, S.W.A.

    carentes de oxigeno. Se describen los impactos de la deficiencia de oxigeno sobre la biogcoquimica, especial- mente sobre las transformaciones anaerobicas del nitrogeno. Se realizara una comparacion entre la ZMO mesopelagica perenne del Occano Indico nor...-occidental y un sistema deficicnte en oxigeno mas somero que se desarrolla estacionalmente (durante el final del verano y el otono) sobre la plataforma continental de la India occidental. Este ultimo parece inlensificarse en los ultimos anos debido a la carga...

  12. A multiplexed electronic architecture for opto-electronic patch sensor to effectively monitor heart rate and oxygen saturation

    Science.gov (United States)

    Yan, Liangwen; Hu, Sijung; Alharbi, Samah; Blanos, Panagiotis

    2018-02-01

    To effectively capture human vital signs, a multi-wavelength optoelectronic patch sensor (MOEPS), together with a schematic architecture of electronics, was developed to overcome the drawbacks of present photoplethysmographic (PPG) sensors. To obtain a better performance of in vivo physiological measurement, the optimal illuminations, i.e., light emitting diodes (LEDs) in the MOEPS, whose wavelength is automatically adjusted to each specific subject, were selected to capture better PPG signals. A multiplexed electronic architecture has been well established to properly drive the MOEPS and effectively capture pulsatile waveforms at rest. The protocol was designed to investigate its performance with the participation of 11 healthy subjects aged between 18 and 30. The signals obtained from green (525nm) and orange (595nm) illuminations were used to extract heart rate (HR) and oxygen saturation (SpO2%). These results were compared with data, simultaneously acquired, from a commercial ECG and a pulse oximeter. Considering the difficulty for current devices to attain the SpO2%, a new computing method, to obtain the value of SpO2%, is proposed depended on the green and orange wavelength illuminations. The values of SpO2% between the MOEPS and the commercial Pulse Oximeter devics showed that the results were in good agreement. The values of HR showed close correlation between commercial devices and the MOEPS (HR: r1=0.994(Green); r2=0.992(Orange); r3=0.975(Red); r4=0.990(IR)).

  13. A Quantitative Method to Monitor Reactive Oxygen Species Production by Electron Paramagnetic Resonance in Physiological and Pathological Conditions

    Science.gov (United States)

    Mrakic-Sposta, Simona; Gussoni, Maristella; Montorsi, Michela; Porcelli, Simone; Vezzoli, Alessandra

    2014-01-01

    The growing interest in the role of Reactive Oxygen Species (ROS) and in the assessment of oxidative stress in health and disease clashes with the lack of consensus on reliable quantitative noninvasive methods applicable. The study aimed at demonstrating that a recently developed Electron Paramagnetic Resonance microinvasive method provides direct evidence of the “instantaneous” presence of ROS returning absolute concentration levels that correlate with “a posteriori” assays of ROS-induced damage by means of biomarkers. The reliability of the choice to measure ROS production rate in human capillary blood rather than in plasma was tested (step I). A significant (P < 0.01) linear relationship between EPR data collected on capillary blood versus venous blood (R 2 = 0.95), plasma (R 2 = 0.82), and erythrocytes (R 2 = 0.73) was found. Then (step II) ROS production changes of various subjects' categories, young versus old and healthy versus pathological at rest condition, were found significantly different (range 0.0001–0.05 P level). The comparison of the results with antioxidant capacity and oxidative damage biomarkers concentrations showed that all changes indicating increased oxidative stress are directly related to ROS production increase. Therefore, the adopted method may be an automated technique for a lot of routine in clinical trials. PMID:25374651

  14. What Are Rare Clotting Factor Deficiencies?

    Science.gov (United States)

    ... Deficiency Factor V Deficiency Combined FV & FVIII Deficiencies Factor VII Deficiency Factor X Deficiency Factor XI Deficiency Factor ... Deficiency Factor V Deficiency Combined FV & FVIII Deficiencies Factor VII Deficiency Factor X Deficiency Factor XI Deficiency Factor ...

  15. Simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in humans and other animal models using a single light source

    Science.gov (United States)

    Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.

    2018-02-01

    We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Research Home / < Back To Health Topics / Iron-Deficiency Anemia Iron-Deficiency Anemia Also known as Leer en español Iron-deficiency ... iron-deficiency anemia. Blood tests to screen for iron-deficiency anemia To screen for iron-deficiency anemia, your doctor ...

  17. Iron deficiency

    DEFF Research Database (Denmark)

    Schou, Morten; Bosselmann, Helle; Gaborit, Freja

    2015-01-01

    BACKGROUND: Both iron deficiency (ID) and cardiovascular biomarkers are associated with a poor outcome in heart failure (HF). The relationship between different cardiovascular biomarkers and ID is unknown, and the true prevalence of ID in an outpatient HF clinic is probably overlooked. OBJECTIVES.......043). CONCLUSION: ID is frequent in an outpatient HF clinic. ID is not associated with cardiovascular biomarkers after adjustment for traditional confounders. Inflammation, but not neurohormonal activation is associated with ID in systolic HF. Further studies are needed to understand iron metabolism in elderly HF...

  18. Oxygen dosing the surface of SrTiO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Dudy, L.; Scheiderer, P.; Schuetz, P.; Gabel, J.; Buchwald, M.; Sing, M.; Claessen, R. [Physikalisches Institut, Universitaet Wuerzburg (Germany); Denlinger, J.D. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA, 94270 (United States); Schlueter, C.; Lee, T.L. [Diamond Light Source Ltd., Didcot, Oxfordshire (United Kingdom)

    2015-07-01

    The highly mobile two-dimensional electron system (2DES) on the surface of the insulating SrTiO{sub 3}(STO) offers exciting perspectives for advanced material design. This 2DES resides in a depletion layer caused by oxygen deficiency of the surface. With photoemission spectroscopy, we monitor the appearance of quasi-particle weight (QP) at the Fermi energy and oxygen vacancy induced states in the band gap (IG). Both, QP and IG weight, increase and decrease respectively upon exposure to extreme ultraviolet (XUV) light and in-situ oxygen dosing. By a proper adjustment of oxygen dosing, any intermediate state can be stabilized providing full control over the charge carrier density. From a comparison of the charge carrier concentrations obtained from an analysis of core-level spectra and the Fermi-surface volume, we conclude on a spatially inhomogeneous surface electronic structure with at least two different phases.

  19. Oxygen toxicity

    Directory of Open Access Journals (Sweden)

    C. A. van der Westhuizen

    1990-07-01

    Full Text Available Oxygen has been discovered about 200 years ago. Since then the vital physiological involvement of oxygen in various biologi­cal processes, mainly energy production, has been established. However, in the body molecular oxygen can be converted to toxic oxygen metabolites such as superoxide anion, hydrogen peroxide, the hydroxyl radical and singlet oxygen. These toxic metabolites are produced mainly in the mitochondria, plasma membranes and endoplasmic reticulum.

  20. Assessment and Use of Optical Oxygen Sensors as Tools to Assist in Optimal Product Component Selection for the Development of Packs of Ready-to-Eat Mixed Salads and for the Non-Destructive Monitoring of in-Pack Oxygen Levels Using Chilled Storage.

    Science.gov (United States)

    Hempel, Andreas W; O'Sullivan, Maurice G; Papkovsky, Dmitri B; Kerry, Joseph P

    2013-05-22

    Optical oxygen sensors were used to ascertain the level of oxygen consumed by individual salad leaves for optimised packaging of ready-to-eat (RTE) Italian salad mixes during refrigerated storage. Seven commonly found leaves in Italian salad mixes were individually assessed for oxygen utilisation in packs. Each leaf showed varying levels of respiration throughout storage. Using the information obtained, an experimental salad mix was formulated (termed Mix 3) which consisted of the four slowest respiring salad leaves-Escarole, Frisee, Red Batavia, Lollo Rosso. Mix 3 was then compared against two commercially available Italian salads; Mix 1 (Escarole, Frisee, Radicchio, Lollo Rosso) and Mix 2 (Cos, Frisee, Radicchio, Lollo Rosso). Optical sensors were used to non-destructively monitor oxygen usage in all mixes throughout storage. In addition to oxygen consumption, all three salad mixes were quality assessed in terms of microbial load and sensorial acceptability. In conclusion, Mix 3 was found to consume the least amount of oxygen over time, had the lowest microbial load and was most sensorially preferred ( p products.

  1. Four-years experience with monitoring of persons at the treatment of children patients with neuroblastoma by 131I-MIBG combination with hyperbaric oxygen therapy

    International Nuclear Information System (INIS)

    Hermanska, J.; Zimak, J.; Paskova, Z.; Dosel, P.

    2001-01-01

    Treatment of children patients with neuroblastoma by 131 I-MIBG in combination with hyperbaric oxygen therapy (HBO) started in the Czech Republic in 1997. Estimation of radiation load from extemal irradiation plays very important role in the treatment scheme elaborated at the Department of Nuclear Medicine. According to this scheme, activities of 5.5 GBq and 3.7 GBq are administered at the first and repeated therapies,respectively. 3 rd , 4 th , 5 th and 6 th day after the administration patients undergo HBO in the Institute of Aviation Medicine Prague. Activity administration and following care are realised at the bed station of the Department of Nuclear Medicine, which is the workplace of III. category with unsealed radionuclide sources. Real dose equivalents were checked during the reported four-year period. Members of both groups were equipped by personal digital dosemeters STEPHEN 6000 for inspection. From the presented results, the following conclusions can be drawn: (1) Monitoring of family members has to be performed in spite of the fact that exceeding of equivalent dose of 5 mSv is non-realistic. Unexpected situation concerning behaviour of both parents and children cannot be excluded. Moreover, records of H-values have to be stored and analysed in the case of possible pregnancy. (2) A question arises in connection with the special limit 5 mSv: What is the whole time of the treatment? Is it possible to understand it, similarly as in the case of iodine therapy, as 5 mSv per year or is it necessary to take into account really the whole, often very long, time of the treatment? (3) Monitoring of the staff maintaining the hyperbaric chamber and ambulance drivers seems to be unnecessary. Under normal condition, the staff is outside the chamber and its contact with a patient is minimal. In unusual situation, the instructed nurse from the Department of Nuclear Medicine equipped by STEPHEN 6000 will estimate dose equivalent and contact responsible medical

  2. Real time monitoring and quantification of reactive oxygen species in breast cancer cell line MCF-7 by 2',7'-dichlorofluorescin diacetate (DCFDA) assay.

    Science.gov (United States)

    Figueroa, Daniela; Asaduzzaman, Mohammad; Young, Fiona

    2018-04-07

    The detection of reactive oxygen species (ROS) using 2',7'-dichlorofluorescin diacetate (DCFDA) is commonly performed by a single measurement of fluorescence but this fails to capture a profile of ROS generation over time. This study aimed to develop a real-time monitoring method to increase the utility of the assay, to incorporate cytotoxicity screening and to describe the combined effects of DCFDA and the ROS generator, Ter-butyl hydrogen peroxide (TBHP). Breast cancer MCF-7 cells were loaded with DCFDA (0-50 μM) for 45 min, and then exposed to TBHP (0-50 μM). Fluorescence was recorded according to three different schedules: every hour for 6 h, or once after 6 h or 24 h. Viability was assessed in a crystal violet assay and cell morphology was examined by microscopy. TBHP caused a time and dose-dependent increase in ROS and the magnitude of the fluorescent signal was affected by the loading concentration of DCFDA. Reading the fluorescence every hour for 6 h did not diminish the emission signal. The most sensitive and reliable combination for this ROS assay was 10 μM DCFDA with 25 μM TBHP; since higher concentrations of DCFDA compromised cell viability. In conclusion we adapted a single point ROS assay to enable production of a profile of ROS generation over an extended 6 h period, and related this to cell viability and morphology. Published by Elsevier Inc.

  3. Making sense of monitoring data using Jupyter Notebooks: a case study of dissolved oxygen dynamics across a fresh-estuarine gradient

    Science.gov (United States)

    Nelson, N.; Munoz-Carpena, R.

    2016-12-01

    In the presented exercise, students (advanced undergraduate-graduate) explore dissolved oxygen (DO) dynamics at three locations along a fresh-estuarine gradient of the Lower St. Johns River, FL (USA). Spatiotemporal DO trends along this gradient vary as a function of (1) tidal influence, and (2) biotic productivity (phytoplankton photosynthesis and community respiration). This combination of influences produces distinct DO behavior across each of the three hydrologically-connected sites. Through analysis of high frequency monitoring data, students are encouraged to think critically about the roles of physical and biological drivers of DO, and how the relative importance of these factors can vary among different locations within a single tidal waterbody. Data from each of the three locations along the river are downloaded with CUAHSI HydroClient, and analysis is performed with a Python-enabled Jupyter Notebook that has been specifically created for this assignment. Jupyter Notebooks include annotated code organized into blocks that are executed one-at-a-time; this format is amenable to classroom teaching, and provides an approachable introduction to Python for inexperienced coders. The outputs from each code block (i.e. graphs, tables) are produced within the Jupyter Notebook, thus allowing students to directly interact with the code. Expected student learning outcomes include increased spatial reasoning, as well as greater understanding of DO cycling, spatiotemporal variability in tidal systems, and challenges associated with collecting and evaluating large data sets. Specific technical learning outcomes include coding in Python for data management and analysis using Jupyter notebooks. This assignment and associated materials are open-access and available on the Science Education Resource Center website.

  4. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... To Health Topics / Iron-Deficiency Anemia Iron-Deficiency Anemia Also known as Leer en español Iron-deficiency ... anemia. Blood tests to screen for iron-deficiency anemia To screen for iron-deficiency anemia, your doctor ...

  5. Iron-Deficiency Anemia

    Science.gov (United States)

    ... To Health Topics / Iron-Deficiency Anemia Iron-Deficiency Anemia Also known as Leer en español Iron-deficiency ... anemia. Blood tests to screen for iron-deficiency anemia To screen for iron-deficiency anemia, your doctor ...

  6. Real-time monitoring of nitric oxide (NO) and pO2 levels under ischemic conditions associated with small bowel ischemia/reperfusion injury using selective electrodes for NO and oxygen molecules.

    Science.gov (United States)

    Watanabe, T; Owada, S; Kobayashi, H; Ishiuchi, A; Nakano, H; Asakuta, T; Shimamura, T; Asano, T; Koizumi, S; Jinnouchi, Y; Katayama, M; Kamibayasi, M; Murakami, E; Otsubo, T

    2007-12-01

    The present study demonstrated the feasibility of monitoring nitric oxide (NO) and pO2 levels under ischemic conditions associated with small bowel ischemia/reperfusion (I/R) injury through the use of selective electrodes for NO and oxygen molecules. NO levels gradually increased during ischemia. When reperfusion was started, the NO level decreased suddenly and returned to pre-ischemia values within 10 minutes. After clamping, pO2 decreased rapidly. When reperfusion was started, pO2 increased suddenly, returning to pre-ischemia values within 10 minutes. We concluded that it is feasible to monitor NO and pO2 levels under ischemic conditions of small bowel I/R injury through the use of electrodes selective for NO and oxygen molecules.

  7. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... you are diagnosed with iron-deficiency anemia. Risk Factors You may have an increased risk for iron- ... iron-deficiency anemia if you have certain risk factors , including pregnancy. To prevent iron-deficiency anemia, your ...

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... to moderate iron-deficiency anemia, or red blood cell transfusion for severe iron-deficiency anemia. You may ... body needs iron to make healthy red blood cells. Iron-deficiency anemia usually develops over time because ...

  9. Vitamin Deficiency Anemia

    Science.gov (United States)

    ... are unique to specific vitamin deficiencies. Folate-deficiency anemia risk factors include: Undergoing hemodialysis for kidney failure. ... the metabolism of folate. Vitamin B-12 deficiency anemia risk factors include: Lack of intrinsic factor. Most ...

  10. Oxygen engineering of HfO{sub 2-x} thin films grown by reactive molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Hildebrandt, Erwin; Kurian, Jose; Alff, Lambert [Institut fuer Materialwissenschaft, TU-Darmstadt (Germany); Zaumseil, Peter; Schroeder, Thomas [IHP, Frankfurt, Oder (Germany)

    2010-07-01

    Reactive molecular beam epitaxy (R-MBE) is an ideal tool for tailoring physical properties of thin films to specific needs. For the development of cutting-edge oxides for thin film applications a precise control of oxygen defects is crucial. R-MBE in combination with rf-activated oxygen allows reproducibly growing oxide thin films with precise oxidation conditions enabling oxygen engineering. R-MBE was used to grow Hf and HfO{sub 2{+-}}{sub x} thin films with different oxidation conditions on sapphire single crystal substrates. Structural characterization was carried out using rotating anode x-ray diffraction revealing highly textured to epitaxial thin films on c-cut sapphire. Furthermore, switching of film orientation by varying the oxidation conditions was observed demonstrating the role of oxygen in the growth procedure. The investigation of electrical properties using a four probe measurement setup showed conductivities in the range of 1000 {mu}{omega}cm for oxygen deficient HfO{sub 2-x} thin films. Optical properties were investigated using a photospectrometer and additionally x-ray photoelectron spectroscopy was carried out to study the band gap and valence states. Both techniques were used to monitor the oxygen content in deficient HfO{sub 2-x} thin films. Our results demonstrate the importance of oxygen engineering even in the case of 'simple' oxides.

  11. [Values of mixed venous oxygen saturation and difference of mixed venous-arterial partial pressure of carbon dioxide in monitoring of oxygen metabolism and treatment after open-heart operation].

    Science.gov (United States)

    Pan, Chuanliang; Zhang, Haiying; Liu, Jianping

    2014-10-01

    To explore the clinic values of early goal directed treatment (EGDT) with the target of mixed venous oxygen saturation (SvO₂) and difference of mixed venous-arterial partial pressure of carbon dioxide (Pv-aCO₂) in monitoring of oxygen metabolism and treatment for patients post open-heart operation. A prospective study was conducted. The adult patients admitted to Third People's Hospital of Chengdu from December 2011 to March 2014 with SvO₂2 mmol/L when admitted in intensive care unit (ICU) were selected on whom elective open-heart operation and pulmonary artery catheter examination were done. All patients received EGDT with the target of SvO₂≥0.65 and Pv-aCO₂<6 mmHg (1 mmHg=0.133 kPa) and were divided into three groups by the values of SvO₂and Pv-aCO₂at 6-hour after ICU admission: A group with SvO₂≥0.65 and Pv-aCO₂<6 mmHg, B group with SvO₂≥0.65 and Pv-aCO₂≥6 mmHg, and C group with SvO₂<0.65. Then the changes and prognosis of the patients in different groups were observed. 103 cases were included, 44 in A group, 31 in B group and 28 in C group. The acute physiology and chronic health evaluation II (APACHEII) score in group A were significantly lower than that in group B or C at 6, 24, 48 and 72 hours (T6, T24, T48, T72) of ICU admission (T6: 11.4 ± 5.8 vs. 13.9 ± 5.4, 13.7 ± 6.4; T24: 8.8 ± 3.7 vs. 10.8 ± 4.8, 11.8 ± 5.4; T48: 8.7 ± 4.1 vs. 9.6 ± 4.2, 10.2 ± 5.1; T72: 7.5 ± 3.4 vs. 8.6 ± 2.9, 9.2 ± 4.2, all P<0.05), and the sequential organ failure assessment (SOFA) showed the same tendency (T6: 6.5 ± 4.3 vs. 8.0 ± 3.8, 9.1 ± 4.5; T24: 6.6 ±3.6 vs. 8.6 ± 3.9, 8.5 ± 3.3; T48: 5.2 ± 3.4 vs. 7.0 ± 3.6, 7.6 ± 5.1; T72: 4.6 ± 2.4 vs. 5.8 ± 2.5, 6.8 ± 3.5, all P<0.05). The values of blood lactic acid (mmol/L) in group A and B were significant lower than that in group C at T6, T24, T48 and T72 (T6: 1.60 ± 0.95, 2.20 ± 1.02 vs. 2.55 ± 1.39; T24: 2.26 ± 1.26, 2.70 ± 1.36 vs. 3.34 ± 2.36; T48: 2.01 ± 1.15, 2.17

  12. Oxygen Therapy

    Science.gov (United States)

    ... their breathing to dangerously low levels. Will I need oxygen when I sleep? Usually if you use supplemental oxygen during the ... your health care provider tells you you only need to use oxygen for exercise or sleep. Even if you feel “fine” off of your ...

  13. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  14. Oxygen Therapy

    Directory of Open Access Journals (Sweden)

    Bonnie Solmes

    2000-01-01

    Full Text Available LTOT is prescribed for people with chronic lung disease in whom there is a decrease in the ability of the lungs to supply enough oxygen to the body. The heart is obliged to pump faster to meet the body's oxygen requirements. This may place undue stress on the heart, resulting in palpitations, dizziness and fatigue. A low oxygen level in arterial blood is also harmful to the heart, the brain and the pulmonary blood vessels. Oxygen therapy is used to break this cycle. A person with low blood oxygen will often be able to accomplish more with less fatigue with the help of supplemental oxygen therapy. Shortness of breath is a mechanical problem resulting from the effects of chronic obstructive pulmonary disease. Oxygen therapy may or may not reduce shortness of breath, but it will help the lungs and heart to function with less stress.

  15. The use of heterozygote soybean chlorophyll-deficient mutant gene Y11 as a test-system for environmental monitoring after the Chernobyl accident

    International Nuclear Information System (INIS)

    Rashidov, N.; Grodzinski, D.

    1994-01-01

    A heterozygote soybean line contains a gene of chlorophyll-deficiency, y 11 gene. The gene Y 11 is only partially dominant over y 11 ; thus heterozygote Y 11 y 11 plant has leaves of light green colour. Mitotic crossing-over and somatic mosaicism on Y 11 y 11 leaves of heterozygote plants are observed by scheme Y 11 Y 11 - Y 11 y 11 - y 11 y 11 as double and/or single spots. Investigation has been carried out to evaluate the low level radioactivity effects on heterozygote soybean as test-system. Solution of 3 H 2 O and 90 SrCl 2 has been used as a beta-source. The seeds were soaked in 3 H 2 O (0.2 MBq/ml) for 96 h or in 90 SrCl 2 water solution (10 MBq/ml) during 3 days. The effects of beta-irradiation were compared with the data from experiments with acute gamma-irradiation. The dose used ranged from 1 to 30 Gy (dose rate 0.14 Gy/c). Some experimental plots were also selected in Kiev, Zaporozhe regions and in the 10-km zone around Chernobyl. In the field experiments the lowest frequency of somatic mutation was registered in Kiev and Zaporozhe region where the environmental conditions were comparatively clear. But for the low accumulated doses in the 10-km zone around Chernobyl and in the laboratory experiments with beta-irradiation (for 3 H and 90 Sr), the genetic effects were high enough. It is necessary to take into account that for acute gamma-irradiation a nearly linear relationship between the dose and frequency of the somatic mutation was estimated. This fact allows to determine RBE for environmental pollution with various radioactive isotopes. It is proposed to use the heterozygote soybean as a sensitive test-system for studying the genetic effects in radioactive contaminated areas of Chernobyl region. (author)

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Iron-Deficiency Anemia Iron-Deficiency Anemia Also known as Leer en español Iron-deficiency anemia is a ... address the cause of your iron deficiency, such as any underlying bleeding. If undiagnosed or untreated, iron- ...

  17. Optical response of oxygen deficient La{sub 0.7}Sr{sub 0.3}MnO{sub 3} thin films deposited by pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Cesaria, M., E-mail: maura.cesaria@le.infn.it [Department of Mathematics and Physics “Ennio De Giorgi”, University of Salento, Via Arnesano, 73100 Lecce (Italy); Caricato, A.P.; Leggieri, G.; Martino, M. [Department of Mathematics and Physics “Ennio De Giorgi”, University of Salento, Via Arnesano, 73100 Lecce (Italy); Maruccio, G. [Department of Mathematics and Physics “Ennio De Giorgi”, University of Salento, Via Arnesano, 73100 Lecce (Italy); National Nanotechnology Laboratory (NNL)-Nanoscience Institute-CNR, Via Arnesano, 73100 Lecce (Italy)

    2013-10-31

    The optical response of 200 nm thick La{sub 0.7}Sr{sub 0.3}MnO{sub (3−δ)} films, deposited by pulsed laser deposition on amorphous silica substrates heated at nearly 600 °C, under different oxygen pressures (0.1 Pa, 0.5 Pa, 1 Pa, 5 Pa and 10 Pa), is reported. The effects of the oxygen non-stoichiometry are investigated at room temperature dealing with the absorption coefficient and the Tauc's plot method rather than conventional optical conductivity. The absorption curves are evaluated by an algorithm able to realistically describe the behavior of thin films without exploiting numerical extrapolations or simplified theoretical models or ab-initio calculations. Optical features, tunable by the growth oxygen pressure, are discussed based on the known theoretical and experimental scenario. - Highlights: • Overview of the La{sub 0.7}Sr{sub 0.3}MnO{sub 3} basics to highlight basic questions to be assessed. • Optical analysis by the absorption coefficient rather than optical conductivity. • Realistic absorption response that avoids numerical refinements and simulations. • Analysis of the role of oxygen vacancies in tuning the electronic dispersion. • First investigation of direct and indirect transitions by the Tauc's plot.

  18. Oxygen tension regulates the miRNA profile and bioactivity of exosomes released from extravillous trophoblast cells - Liquid biopsies for monitoring complications of pregnancy.

    Directory of Open Access Journals (Sweden)

    Grace Truong

    Full Text Available Our understanding of how cells communicate has undergone a paradigm shift since the recent recognition of the role of exosomes in intercellular signaling. In this study, we investigated whether oxygen tension alters the exosome release and miRNA profile from extravillous trophoblast (EVT cells, modifying their bioactivity on endothelial cells (EC. Furthermore, we have established the exosomal miRNA profile at early gestation in women who develop pre-eclampsia (PE and spontaneous preterm birth (SPTB. HTR-8/SVneo cells were used as an EVT model. The effect of oxygen tension (i.e. 8% and 1% oxygen on exosome release was quantified using nanocrystals (Qdot® coupled to CD63 by fluorescence NTA. A real-time, live-cell imaging system (Incucyte™ was used to establish the effect of exosomes on EC. Plasma samples were obtained at early gestation (<18 weeks and classified according to pregnancy outcomes. An Illumina TrueSeq Small RNA kit was used to construct a small RNA library from exosomal RNA obtained from EVT and plasma samples. The number of exosomes was significantly higher in EVT cultured under 1% compared to 8% oxygen. In total, 741 miRNA were identified in exosomes from EVT. Bioinformatic analysis revealed that these miRNA were associated with cell migration and cytokine production. Interestingly, exosomes isolated from EVT cultured at 8% oxygen increased EC migration, whilst exosomes cultured at 1% oxygen decreased EC migration. These changes were inversely proportional to TNF-α released from EC. Finally, we have identified a set of unique miRNAs in exosomes from EVT cultured at 1% oxygen and exosomes isolated from the circulation of mothers at early gestation, who later developed PE and SPTB. We suggest that aberrant exosomal signalling by placental cells is a common aetiological factor in pregnancy complications characterised by incomplete SpA remodeling and is therefore a clinically relevant biomarker of pregnancy complications.

  19. DNA repair deficiency in neurodegeneration

    DEFF Research Database (Denmark)

    Jeppesen, Dennis Kjølhede; Bohr, Vilhelm A; Stevnsner, Tinna V.

    2011-01-01

    Deficiency in repair of nuclear and mitochondrial DNA damage has been linked to several neurodegenerative disorders. Many recent experimental results indicate that the post-mitotic neurons are particularly prone to accumulation of unrepaired DNA lesions potentially leading to progressive...... neurodegeneration. Nucleotide excision repair is the cellular pathway responsible for removing helix-distorting DNA damage and deficiency in such repair is found in a number of diseases with neurodegenerative phenotypes, including Xeroderma Pigmentosum and Cockayne syndrome. The main pathway for repairing oxidative...... base lesions is base excision repair, and such repair is crucial for neurons given their high rates of oxygen metabolism. Mismatch repair corrects base mispairs generated during replication and evidence indicates that oxidative DNA damage can cause this pathway to expand trinucleotide repeats, thereby...

  20. First-Principles Study on Cathode Properties of Li2MTiO4 (M = V, Cr, Mn, Fe, Co, and Ni) with Oxygen Deficiency for Li-Ion Batteries

    Science.gov (United States)

    Hamaguchi, Motoyuki; Momida, Hiroyoshi; Oguchi, Tamio

    2018-04-01

    We study the cathode properties of Li2MTiO4 (M = V, Cr, Mn, Fe, Co, and Ni) for Li-ion batteries by performing first-principles calculations. Formation energies and voltages for Li2-xMTiO4 (0 ≤ x ≤ 2) models with rock-salt-based structures considering several Li concentrations (2 - x) are calculated. Two dominant charge/discharge reaction mechanisms associated with redox reactions of M and O are found mainly in the ranges of lower and higher x, respectively. In the higher-x region, the O redox reactions can destabilize atomic structures, because the electron removal from O-p states produces high peaks at the fermi level in the density of states. The structural stability of O using the models with O deficiency is calculated, and the result shows that O can dissociate much more easily than Li in the higher-x region. The critical Li concentration at which the vacancy formation energy of O becomes lower than that of Li is estimated, and the critical x value decreases with increasing number of 3d electrons as M changes from V to Ni. The calculated voltages of Li2MTiO4 with O deficiency are lower than those without O deficiency, showing that the O dissociation degrades battery performances. Our systematic study for the series of M predicts that Li2CrTiO4 may be the best cathode material considering its cathode properties of high voltage and stability against O dissociation.

  1. In Situ Resource Utilization (ISRU) on the Moon: Moessbauer Spectroscopy as a Process Monitor for Oxygen Production. Results from a Field Test on Mauna Kea Volcano, Hawaii

    Science.gov (United States)

    Morris, R.V.; Schroder, C.; Graff, T.G.; Sanders, G.B.; Lee, K.A.; Simon, T.M.; Larson, W.E.; Quinn, J.W.; Clark, L.D.; Caruso, J.J.

    2009-01-01

    Essential consumables like oxygen must to be produced from materials on the lunar surface to enable a sustained, long-term presence of humans on the Moon. The Outpost Precursor for ISRU and Modular Architecture (OPTIMA) field test on Mauna Kea, Hawaii, facilitated by the Pacific International Space Center for Exploration Systems (PISCES) of the University of Hawaii at Hilo, was designed to test the implementation of three hardware concepts to extract oxygen from the lunar regolith: Precursor ISRU Lunar Oxygen Testbed (PILOT) developed by Lockheed Martin in Littleton, CO; Regolith & Environmental Science and Oxygen & Lunar Volatiles Extraction (RESOLVE) developed at the NASA Kennedy Space Center in Cape Canaveral, FL; and ROxygen developed at the NASA Johnson Space Center in Houston, TX. The three concepts differ in design, but all rely on the same general principle: hydrogen reduction of metal cations (primarily Fe2+) bonded to oxygen to metal (e.g., Fe0) with the production of water. The hydrogen source is residual hydrogen in the fuel tanks of lunar landers. Electrolysis of the water produces oxygen and hydrogen (which is recycled). We used the miniaturized M ssbauer spectrometer MIMOS II to quantify the yield of this process on the basis of the quantity of Fe0 produced. Iron M ssbauer spectroscopy identifies iron-bearing phases, determines iron oxidation states, and quantifies the distribution of iron between mineral phases and oxidation states. The oxygen yield can be calculated by quantitative measurements of the distribution of Fe among oxidation states in the regolith before and after hydrogen reduction. A M ssbauer spectrometer can also be used as a prospecting tool to select the optimum feedstock for the oxygen production plants (e.g., high total Fe content and easily reduced phases). As a demonstration, a MIMOS II backscatter spectrometer (SPESI, Germany) was mounted on the Cratos rover (NASA Glenn Research Center in Cleveland, OH), which is one of

  2. Monitoring Tumor Response to Carbogen Breathing by Oxygen-Sensitive Magnetic Resonance Parameters to Predict the Outcome of Radiation Therapy: A Preclinical Study

    Energy Technology Data Exchange (ETDEWEB)

    Cao-Pham, Thanh-Trang; Tran, Ly-Binh-An; Colliez, Florence; Joudiou, Nicolas [Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Brussels (Belgium); El Bachiri, Sabrina [Université Catholique de Louvain, IMMAQ Technological Platform, Methodology and Statistical Support, Louvain-la-Neuve (Belgium); Grégoire, Vincent [Université Catholique de Louvain, Institute of Experimental and Clinical Research, Center for Molecular Imaging, Radiotherapy and Oncology, Brussels (Belgium); Levêque, Philippe; Gallez, Bernard [Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Brussels (Belgium); Jordan, Bénédicte F., E-mail: benedicte.jordan@uclouvain.be [Université Catholique de Louvain, Louvain Drug Research Institute, Biomedical Magnetic Resonance Research Group, Brussels (Belgium)

    2016-09-01

    Purpose: In an effort to develop noninvasive in vivo methods for mapping tumor oxygenation, magnetic resonance (MR)-derived parameters are being considered, including global R{sub 1}, water R{sub 1}, lipids R{sub 1}, and R{sub 2}*. R{sub 1} is sensitive to dissolved molecular oxygen, whereas R{sub 2}* is sensitive to blood oxygenation, detecting changes in dHb. This work compares global R{sub 1}, water R{sub 1}, lipids R{sub 1}, and R{sub 2}* with pO{sub 2} assessed by electron paramagnetic resonance (EPR) oximetry, as potential markers of the outcome of radiation therapy (RT). Methods and Materials: R{sub 1}, R{sub 2}*, and EPR were performed on rhabdomyosarcoma and 9L-glioma tumor models, under air and carbogen breathing conditions (95% O{sub 2}, 5% CO{sub 2}). Because the models demonstrated different radiosensitivity properties toward carbogen, a growth delay (GD) assay was performed on the rhabdomyosarcoma model and a tumor control dose 50% (TCD50) was performed on the 9L-glioma model. Results: Magnetic resonance imaging oxygen-sensitive parameters detected the positive changes in oxygenation induced by carbogen within tumors. No consistent correlation was seen throughout the study between MR parameters and pO{sub 2}. Global and lipids R{sub 1} were found to be correlated to pO{sub 2} in the rhabdomyosarcoma model, whereas R{sub 2}* was found to be inversely correlated to pO{sub 2} in the 9L-glioma model (P=.05 and .03). Carbogen increased the TCD50 of 9L-glioma but did not increase the GD of rhabdomyosarcoma. Only R{sub 2}* was predictive (P<.05) for the curability of 9L-glioma at 40 Gy, a dose that showed a difference in response to RT between carbogen and air-breathing groups. {sup 18}F-FAZA positron emission tomography imaging has been shown to be a predictive marker under the same conditions. Conclusion: This work illustrates the sensitivity of oxygen-sensitive R{sub 1} and R{sub 2}* parameters to changes in tumor oxygenation. However, R{sub 1

  3. Monitoring Tumor Response to Carbogen Breathing by Oxygen-Sensitive Magnetic Resonance Parameters to Predict the Outcome of Radiation Therapy: A Preclinical Study

    International Nuclear Information System (INIS)

    Cao-Pham, Thanh-Trang; Tran, Ly-Binh-An; Colliez, Florence; Joudiou, Nicolas; El Bachiri, Sabrina; Grégoire, Vincent; Levêque, Philippe; Gallez, Bernard; Jordan, Bénédicte F.

    2016-01-01

    Purpose: In an effort to develop noninvasive in vivo methods for mapping tumor oxygenation, magnetic resonance (MR)-derived parameters are being considered, including global R_1, water R_1, lipids R_1, and R_2*. R_1 is sensitive to dissolved molecular oxygen, whereas R_2* is sensitive to blood oxygenation, detecting changes in dHb. This work compares global R_1, water R_1, lipids R_1, and R_2* with pO_2 assessed by electron paramagnetic resonance (EPR) oximetry, as potential markers of the outcome of radiation therapy (RT). Methods and Materials: R_1, R_2*, and EPR were performed on rhabdomyosarcoma and 9L-glioma tumor models, under air and carbogen breathing conditions (95% O_2, 5% CO_2). Because the models demonstrated different radiosensitivity properties toward carbogen, a growth delay (GD) assay was performed on the rhabdomyosarcoma model and a tumor control dose 50% (TCD50) was performed on the 9L-glioma model. Results: Magnetic resonance imaging oxygen-sensitive parameters detected the positive changes in oxygenation induced by carbogen within tumors. No consistent correlation was seen throughout the study between MR parameters and pO_2. Global and lipids R_1 were found to be correlated to pO_2 in the rhabdomyosarcoma model, whereas R_2* was found to be inversely correlated to pO_2 in the 9L-glioma model (P=.05 and .03). Carbogen increased the TCD50 of 9L-glioma but did not increase the GD of rhabdomyosarcoma. Only R_2* was predictive (P<.05) for the curability of 9L-glioma at 40 Gy, a dose that showed a difference in response to RT between carbogen and air-breathing groups. "1"8F-FAZA positron emission tomography imaging has been shown to be a predictive marker under the same conditions. Conclusion: This work illustrates the sensitivity of oxygen-sensitive R_1 and R_2* parameters to changes in tumor oxygenation. However, R_1 parameters showed limitations in terms of predicting the outcome of RT in the tumor models studied, whereas R_2* was found to be

  4. Dissolved Oxygen Sensor in Animal-Borne Instruments: An Innovation for Monitoring the Health of Oceans and Investigating the Functioning of Marine Ecosystems.

    Science.gov (United States)

    Bailleul, Frederic; Vacquie-Garcia, Jade; Guinet, Christophe

    2015-01-01

    The current decline in dissolved oxygen concentration within the oceans is a sensitive indicator of the effect of climate change on marine environment. However the impact of its declining on marine life and ecosystems' health is still quite unclear because of the difficulty in obtaining in situ data, especially in remote areas, like the Southern Ocean (SO). Southern elephant seals (Mirounga leonina) proved to be a relevant alternative to the traditional oceanographic platforms to measure physical and biogeochemical structure of oceanic regions rarely observed. In this study, we use a new stage of development in biologging technology to draw a picture of dissolved oxygen concentration in the SO. We present the first results obtained from a dissolved oxygen sensor added to Argos CTD-SRDL tags and deployed on 5 female elephant seals at Kerguelen. From October 2010 and October 2011, 742 oxygen profiles associated with temperature and salinity measurements were recorded. Whether a part of the data must be considered cautiously, especially because of offsets and temporal drifts of the sensors, the range of values recorded was consistent with a concomitant survey conducted from a research vessel (Keops-2 project). Once again, elephant seals reinforced the relationship between marine ecology and oceanography, delivering essential information about the water masses properties and the biological status of the Southern Ocean. But more than the presentation of a new stage of development in animal-borne instrumentation, this pilot study opens a new field of investigation in marine ecology and could be enlarged in a near future to other key marine predators, especially large fish species like swordfish, tuna or sharks, for which dissolved oxygen is expected to play a crucial role in distribution and behaviour.

  5. Dissolved Oxygen Sensor in Animal-Borne Instruments: An Innovation for Monitoring the Health of Oceans and Investigating the Functioning of Marine Ecosystems.

    Directory of Open Access Journals (Sweden)

    Frederic Bailleul

    Full Text Available The current decline in dissolved oxygen concentration within the oceans is a sensitive indicator of the effect of climate change on marine environment. However the impact of its declining on marine life and ecosystems' health is still quite unclear because of the difficulty in obtaining in situ data, especially in remote areas, like the Southern Ocean (SO. Southern elephant seals (Mirounga leonina proved to be a relevant alternative to the traditional oceanographic platforms to measure physical and biogeochemical structure of oceanic regions rarely observed. In this study, we use a new stage of development in biologging technology to draw a picture of dissolved oxygen concentration in the SO. We present the first results obtained from a dissolved oxygen sensor added to Argos CTD-SRDL tags and deployed on 5 female elephant seals at Kerguelen. From October 2010 and October 2011, 742 oxygen profiles associated with temperature and salinity measurements were recorded. Whether a part of the data must be considered cautiously, especially because of offsets and temporal drifts of the sensors, the range of values recorded was consistent with a concomitant survey conducted from a research vessel (Keops-2 project. Once again, elephant seals reinforced the relationship between marine ecology and oceanography, delivering essential information about the water masses properties and the biological status of the Southern Ocean. But more than the presentation of a new stage of development in animal-borne instrumentation, this pilot study opens a new field of investigation in marine ecology and could be enlarged in a near future to other key marine predators, especially large fish species like swordfish, tuna or sharks, for which dissolved oxygen is expected to play a crucial role in distribution and behaviour.

  6. Impact of partial pressure of oxygen in blood samples on the performance of systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Schmid, Christina; Baumstark, Annette; Pleus, Stefan; Haug, Cornelia; Tesar, Martina; Freckmann, Guido

    2014-03-01

    The partial pressure of oxygen (pO2) in blood samples can affect glucose measurements with oxygen-sensitive systems. In this study, we assessed the influence of different pO2 levels on blood glucose (BG) measurements with five glucose oxidase (GOD) systems and one glucose dehydrogenase (GDH) system. All selected GOD systems were indicated by the manufacturers to be sensitive to increased oxygen content of the blood sample. Venous blood samples of 16 subjects (eight women, eight men; mean age, 52 years; three with type 1 diabetes, four with type 2 diabetes, and nine without diabetes) were collected. Aliquots of each sample were adjusted to the following pO2 values: ≤45 mm Hg, approximately 70 mm Hg, and ≥150 mm Hg. For each system, five consecutive measurements on each sample were performed using the same test strip lot. Relative differences between the mean BG value at a pO2 level of approximately 70 mm Hg, which was considered to be similar to pO2 values in capillary blood samples, and the mean BG value at pO2 levels ≤45 mm Hg and ≥150 mm Hg were calculated. The GOD systems showed mean relative differences between 11.8% and 44.5% at pO2 values ≤45 mm Hg and between -14.6% and -21.2% at pO2 values ≥150 mm Hg. For the GDH system, the mean relative differences were -0.3% and -0.2% at pO2 values ≤45 mm Hg and ≥150 mm Hg, respectively. The magnitude of the pO2 impact on BG measurements seems to vary among the tested oxygen-sensitive GOD systems. The pO2 range in which oxygen-sensitive systems operate well should be provided in the product information.

  7. [Vitamin B12 deficiency: what's new?].

    Science.gov (United States)

    Braillard, O; Casini, A; Samii, K; Rufenacht, P; Junod, Perron N

    2012-09-26

    Vitamin B12 screening is only recommended among symptomatic patients or in those with risk factors. The main cause of vitamin B12 deficiency is the food cobalamin malabsorption syndrom. Holotranscobalamin is a more reliable marker than cyanocobalamin to confirm vitamin B12 deficiency, but it has not been validated yet in complex situations. An autoimmune gastritis must be excluded in the absence of risk factors but in the presence of a probable deficiency. Oral substitution treatment is effective but requires excellent therapeutic compliance and close follow-up to monitor the response to treatment. It has not yet been studied among patients suffering from severe symptoms, inflammatory bowel disease and ileal resection.

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... fatigue or tiredness, shortness of breath, or chest pain. If your doctor diagnoses you with iron-deficiency ... Common symptoms of iron-deficiency anemia include: Chest pain Coldness in the hands and feet Difficulty concentrating ...

  9. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... heart failure . Increased risk of infections Motor or cognitive development delays in children Pregnancy complications, such as ... for iron-deficiency anemia. Learn about exciting research areas that NHLBI is exploring about iron-deficiency anemia. ...

  10. Factor VII deficiency

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000548.htm Factor VII deficiency To use the sharing features on this page, please enable JavaScript. Factor VII (seven) deficiency is a disorder caused by a ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... deficiency anemia can cause serious complications, including heart failure and development delays in children. Explore this Health ... lead to iron-deficiency anemia include: End-stage kidney failure, where there is blood loss during dialysis. ...

  12. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... for iron-deficiency anemia. Lifestyle habits Certain lifestyle habits may increase your risk for iron-deficiency anemia, including: Vegetarian or vegan eating patterns. Not eating enough iron-rich foods, such ...

  13. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... deficiency anemia can cause serious complications, including heart failure and development delays in children. Explore this Health ... to iron-deficiency anemia include: End-stage kidney failure, where there is blood loss during dialysis. People ...

  14. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... view the colon directly. What if my doctor thinks something else is causing my iron-deficiency anemia? ... deficiency anemia early in life affects later behavior, thinking, and mood during adolescence. Treating anemia in premature ...

  15. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... mg and women need 18 mg. After age 51, both men and women need 8 mg. Pregnant ... for iron-deficiency anemia. Learn about exciting research areas that NHLBI is exploring about iron-deficiency anemia. ...

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia. These conditions include: Intestinal and digestive conditions, such as celiac disease; inflammatory bowel diseases, ... iron-deficiency anemia , such as bleeding in the digestive or urinary tract or heavy menstrual bleeding, your ...

  17. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... conditions that can cause iron-deficiency anemia. Blood tests to screen for iron-deficiency anemia To screen ... the size of your liver and spleen. Blood tests Based on results from blood tests to screen ...

  18. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... from developing iron-deficiency anemia. Foods that are good sources of iron include dried beans, dried fruits, eggs, lean red meat, ... signs of iron-deficiency anemia include: Brittle nails ...

  19. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... your doctor may recommend you eat heart-healthy foods or control other conditions that can cause iron-deficiency anemia. Blood tests to screen for iron-deficiency anemia To screen ...

  20. Fire Safety Deficiencies

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of all fire safety deficiencies currently listed on Nursing Home Compare, including the nursing home that received the deficiency, the associated inspection...

  1. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... learning how having iron-deficiency anemia early in life affects later behavior, thinking, and mood during adolescence. ... iron-deficiency anemia in blood donors affects the quality of donated red blood cells, such as how ...

  2. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia in blood donors affects the quality of donated red blood cells, such as how ... Cells From Iron-deficient Donors: Recovery and Storage Quality. Learn more about participating in a clinical trial . ...

  3. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... leaving cells where it is stored or from being absorbed in the duodenum, the first part of ... treatments for iron-deficiency anemia. Living With After being diagnosed with iron-deficiency anemia, it is important ...

  4. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... cells that carries oxygen from the lungs to tissues and organs in the body. Hemoglobin also carries ... oxygen-rich blood through your body. Cells in tissues need a steady supply of oxygen to work ...

  5. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  6. Fuel cell serves as oxygen level detector

    Science.gov (United States)

    1965-01-01

    Monitoring the oxygen level in the air is accomplished by a fuel cell detector whose voltage output is proportional to the partial pressure of oxygen in the sampled gas. The relationship between output voltage and partial pressure of oxygen can be calibrated.

  7. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... if you are diagnosed with iron-deficiency anemia. Risk Factors You may have an increased risk for iron-deficiency anemia because of your age, ... or sex. Age You may be at increased risk for iron deficiency at certain ages: Infants between ...

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Home / < Back To Health Topics / Iron-Deficiency Anemia Iron-Deficiency Anemia Also known as Leer en español ... bleeding Consuming less than recommended daily amounts of iron Iron-deficiency anemia can be caused by getting ...

  9. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Topics News & Resources Intramural Research Home / < Back To Health Topics / Iron-Deficiency Anemia Iron-Deficiency Anemia Also known as Leer ... and symptoms as well as complications from iron-deficiency anemia. Research for Your Health The NHLBI is part of the U.S. Department ...

  10. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... anemia, your doctor may order the following blood tests to diagnose iron-deficiency anemia: Complete blood count (CBC) to ... than normal when viewed under a microscope. Different tests help your doctor diagnose iron-deficiency anemia. In iron-deficiency anemia, blood ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... for iron-deficiency anemia if you have certain risk factors , including pregnancy. To prevent iron-deficiency anemia, your doctor may recommend you eat heart-healthy foods or control other conditions that can cause iron-deficiency anemia. ...

  12. The treatment of iron deficiency without anaemia (in otherwise healthy persons).

    Science.gov (United States)

    Clénin, German E

    2017-06-21

    Iron deficiency is the most widespread and frequent nutritional disorder in the world. It affects a high proportion of children and women in developing countries and is also significantly prevalent in the industrialised world, with a clear predominance in adolescents and menstruating females. Iron is essential for optimal cognitive function and physical performance, not only as a binding site of oxygen but also as a critical constituent of many enzymes. Therefore iron deficiency at all its levels - nonanaemic iron deficiency, iron deficiency with microcytosis or hypochromia and iron deficiency anaemia - should be treated. In the presence of normal stores, however, preventative iron administration is inefficient, has side effects and seems to be harmful. In symptomatic patients with fatigue or in a population at risk for iron deficiency (adolescence, heavy or prolonged menstruation, high performance sport, vegetarian or vegan diet, eating disorder, underweight), a baseline set of blood tests including haemoglobin concentration, haematocrit, mean cellular volume, mean cellular haemoglobin, percentage of hypochromic erythrocytes and serum ferritin levels are important to monitor iron deficiency. To avoid false negative results (high ferritin levels in spite of iron deficiency), an acute phase reaction should be excluded by history and measurement of C-reactive protein. An algorithm leads through this diagnostic process and the decision making for a possible treatment. For healthy males and females aged >15 years, a ferritin cut-off of 30 µg/l is appropriate. For children from 6-12 years and younger adolescents from 12-15 years, cut-offs of 15 and 20 µg/l, respectively, are recommended. As a first step in treatment, counselling and oral iron therapy are usually combined. Integrating haem and free iron regularly into the diet, looking for enhancers and avoiding inhibitors of iron uptake is beneficial. In order to prevent reduced compliance, mainly as a result of

  13. Formation of neutrophil extracellular traps under low oxygen level

    Directory of Open Access Journals (Sweden)

    Katja Branitzki-Heinemann

    2016-11-01

    Full Text Available Since their discovery, neutrophil extracellular traps (NETs have been characterized as a fundamental host innate immune defense mechanism. Conversely, excessive NET release may have a variety of detrimental consequences for the host. A fine balance between NET formation and elimination is necessary to sustain a protective effect during an infectious challenge. Our own recently published data revealed that stabilization of hypoxia inducible factor 1α (HIF-1α by the iron chelating HIF-1α-agonist desferoxamine or AKB-4924 enhanced the release of phagocyte extracellular traps. Since HIF-1α is a global regulator of the cellular response to low oxygen, we hypothesized that NET formation may be similarly increased under low oxygen conditions. Hypoxia occurs in tissues during infection or inflammation, mostly due to overconsumption of oxygen by pathogens and recruited immune cells. Therefore, experiments were performed to characterize the formation of NETs under hypoxic oxygen conditions compared to normoxia. Human blood-derived neutrophils were isolated and incubated under normoxic (21% oxygen level and compared to hypoxic (1% conditions. Dissolved oxygen levels were monitored in the primary cell culture using a Fibox4-PSt3 measurement system. The formation of NETs was quantified by fluorescence microscopy in response to the known NET-inducer phorbol 12-myristate 13-acetate (PMA or S. aureus wildtype and a nuclease-deficient mutant. In contrast to our hypothesis, spontaneous NET formation of neutrophils incubated under hypoxia was distinctly reduced compared to control neutrophils incubated under normoxia. Furthermore, neutrophils incubated under hypoxia showed significantly reduced formation of NETs in response to PMA. Gene expression analysis revealed that mRNA level of hif-1α as well as hif-1α target genes was not altered. However, in good correlation to the decreased NET formation under hypoxia, the cholesterol content of the neutrophils was

  14. Carnitine Deficiency and Pregnancy

    Directory of Open Access Journals (Sweden)

    Anouk de Bruyn

    2015-01-01

    Full Text Available We present two cases of carnitine deficiency in pregnancy. In our first case, systematic screening revealed L-carnitine deficiency in the first born of an asymptomatic mother. In the course of her second pregnancy, maternal carnitine levels showed a deficiency as well. In a second case, a mother known with carnitine deficiency under supplementation was followed throughout her pregnancy. Both pregnancies had an uneventful outcome. Because carnitine deficiency can have serious complications, supplementation with carnitine is advised. This supplementation should be continued throughout pregnancy according to plasma concentrations.

  15. Monitoring reactive oxygen species formation and localisation in living cells by use of the fluorescent probe CM-H(2)DCFDA and confocal laser microscopy

    DEFF Research Database (Denmark)

    Kristiansen, Kim Anker; Jensen, Poul Erik; Møller, Ian Max

    2009-01-01

    Reactive oxygen species (ROS) develop as a consequence of wounding, light stress and chemical imbalances but act also as signals in living cells. The integrity of cells is seriously endangered, if ROS cannot be controlled by scavenging molecules and other repair mechanisms of the cell. For studying...... ROS development and signalling under stress, a reliable indicator is needed. We have tested the ROS sensitive dye 5-(and-6) chloromethyl-2',7' dichlorodihydrofluorescein diacetate acetyl ester (CM-H(2)DCFDA) using onion bulb scale and leaf epidermis as well as Arabidopsis leaves and protoplasts. ROS...

  16. A Novel, Inexpensive Method to Monitor, Record, and Analyze Breathing Behavior During Normobaric Hypoxia Generated by the Reduced Oxygen Breathing Device.

    Science.gov (United States)

    Temme, Leonard A; St Onge, Paul; Adams, Mark; Still, David L; Statz, Jonathan K; Williams, Steven T

    2017-03-01

    Since hypoxia remains one of the most important physiological hazards the aviation environment poses, military aviators are trained to recognize symptoms of hypoxia in order to implement appropriate safety procedures and countermeasures when hypoxia occurs. A widely used commercial instrument for hypoxia training, demonstration, and research is the Reduced Oxygen Breathing Device (ROBD). Here we describe a novel, inexpensive method to use the ROBD's breathing loop pressure (BLP) to measure respiration rate, a critically important response parameter for hypoxia. The ROBD can be controlled by a computer to export several variables including BLP, via the ROBD's RS232 port. An archived database was reanalyzed to assess the BLP data. New instrumentation added independent measures of respiration and expired oxygen and carbon dioxide; these measures were integrated with the ROBD output. Analysis of the archived data showed that the BLP reflected realistic breathing patterns. The new instrumentation integrated well with the ROBD, and independently supported the potential of the BLP as a valid measure of respiration. The ROBD's BLP data may provide a basis for a reliable, sensitive measure of respiration that is available at no additional cost. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  17. Antiferromagnetic ordering states of oxygen-deficient NdBa2Cu3O6+x and Nd1+yBa2-yCu3O6+x single crystals

    DEFF Research Database (Denmark)

    Brecht, E.; Schweiss, P.; Wolf, T.

    1999-01-01

    The paper describes a study of the antiferromagnetic ordering of oxygen-deficient Nd1 + yBa2 - yCu3O6 + x single crystals. In pure, stoichiometric samples, y = 0, with different oxygen contents x in the Cu(1) plane (0.02AFI) phase appears to be stable down to 316 m...... of this reordering suggests that the Nd3+ ions on Ba sites are very effective defects forcing the AFIAFII reordering. The mechanism of reordering is explained in terms of the creation of Cu2+ moments within the Cu(1) layer due to the Nd3+ ions on Ba sites, which via polarization lead to an effective ferromagnetic...

  18. Oxygen safety

    Science.gov (United States)

    ... sure you have working smoke detectors and a working fire extinguisher in your home. If you move around the house with your oxygen, you may need more than one fire extinguisher in different locations. Smoking can be very dangerous. No one should smoke ...

  19. Oxygen therapy - infants

    Science.gov (United States)

    ... breathe increased amounts of oxygen to get normal levels of oxygen in their blood. Oxygen therapy provides babies with the extra oxygen. Information Oxygen is a gas that the cells in your body need to work properly. The ...

  20. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... increased need for iron during growth spurts. Older adults, especially those over age ... athletes. Athletes, especially young females, are at risk for iron deficiency. Endurance ...

  1. Iodine deficiency disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ali, S M [Pakistan Council for Science and Technology, Islamabad (Pakistan)

    1994-12-31

    Iodine deficiency (IDD) is one of the common problem in the diet. Iodine deficiency as prevalence of goiter in population occurs in the mountainous areas. There is consensus that 800 million people are at risk of IDD from living in iodine deficient area and 190 million from goiter. Very high prevalence of IDD in different parts of the world are striking. It has generally observed that in iodine-deficient areas about 50% are affected with goiter, 1-5% from cretinsim and 20% from impaired mental and/or mortor function. (A.B.).

  2. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Small Business Innovation Research (SBIR) and Small Business Technology Transfer (STTR) programs. Our ... more information about Donor Iron Deficiency Study - Red Blood Cells ...

  3. 42 CFR 488.422 - State monitoring.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false State monitoring. 488.422 Section 488.422 Public... Long-Term Care Facilities with Deficiencies § 488.422 State monitoring. (a) A State monitor— (1... deficiencies on the last 3 consecutive standard surveys. (c) State monitoring is discontinued when— (1) The...

  4. Methods of Blood Oxygen Level-Dependent Magnetic Resonance Imaging Analysis for Evaluating Renal Oxygenation

    Directory of Open Access Journals (Sweden)

    Fen Chen

    2018-03-01

    Full Text Available Blood oxygen level-dependent magnetic resonance imaging (BOLD MRI has recently been utilized as a noninvasive tool for evaluating renal oxygenation. Several methods have been proposed for analyzing BOLD images. Regional ROI selection is the earliest and most widely used method for BOLD analysis. In the last 20 years, many investigators have used this method to evaluate cortical and medullary oxygenation in patients with ischemic nephropathy, hypertensive nephropathy, diabetic nephropathy, chronic kidney disease (CKD, acute kidney injury and renal allograft rejection. However, clinical trials of BOLD MRI using regional ROI selection revealed that it was difficult to distinguish the renal cortico-medullary zones with this method, and that it was susceptible to observer variability. To overcome these deficiencies, several new methods were proposed for analyzing BOLD images, including the compartmental approach, fractional hypoxia method, concentric objects (CO method and twelve-layer concentric objects (TLCO method. The compartmental approach provides an algorithm to judge whether the pixel belongs to the cortex or medulla. Fractional kidney hypoxia, measured by using BOLD MRI, was negatively correlated with renal blood flow, tissue perfusion and glomerular filtration rate (GFR in patients with atherosclerotic renal artery stenosis. The CO method divides the renal parenchyma into six or twelve layers of thickness in each coronal slice of BOLD images and provides a R2* radial profile curve. The slope of the R2* curve associated positively with eGFR in CKD patients. Indeed, each method invariably has advantages and disadvantages, and there is generally no consensus method so far. Undoubtedly, analytic approaches for BOLD MRI with better reproducibility would assist clinicians in monitoring the degree of kidney hypoxia and thus facilitating timely reversal of tissue hypoxia.

  5. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... carrying red blood cells, your heart has to work harder to move oxygen-rich blood through your ... tissues need a steady supply of oxygen to work well. Normally, hemoglobin in red blood cells takes ...

  6. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... exploring about iron-deficiency anemia. Read more New treatments for disorders that lead to iron-deficiency anemia. We are ... and other pathways. This could help develop new therapies for conditions that ... behavior, thinking, and mood during adolescence. Treating anemia in ...

  7. Muscle phosphorylase kinase deficiency

    DEFF Research Database (Denmark)

    Preisler, N; Orngreen, M C; Echaniz-Laguna, A

    2012-01-01

    To examine metabolism during exercise in 2 patients with muscle phosphorylase kinase (PHK) deficiency and to further define the phenotype of this rare glycogen storage disease (GSD).......To examine metabolism during exercise in 2 patients with muscle phosphorylase kinase (PHK) deficiency and to further define the phenotype of this rare glycogen storage disease (GSD)....

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... loss and lead to iron-deficiency anemia. Common causes of blood loss that lead to iron-deficiency anemia include: Bleeding in your GI tract, from an ulcer, colon cancer, or regular use of medicines such as aspirin ...

  9. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia. Search the NIH Research Portfolio Online Reporting Tools (RePORT) to learn about research that ... iron-deficiency anemia in blood donors affects the quality of donated red blood cells, such as how ...

  10. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... blocks the intestine from taking up iron. Other medical conditions Other medical conditions that may lead to iron-deficiency anemia ... daily amount of iron. If you have other medical conditions that cause iron-deficiency anemia , such as ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... anemia if you have certain risk factors , including pregnancy. To prevent iron-deficiency anemia, your doctor may recommend you eat heart-healthy foods or control other conditions that can cause iron-deficiency anemia. Blood tests to screen for ...

  12. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Are you curious about how inflammation from chronic diseases can cause iron-deficiency anemia? Read more When there is ... DBDR) is a leader in research on the causes, prevention, and treatment of blood diseases, including iron-deficiency anemia. Search the NIH Research ...

  13. Nutritional iron deficiency

    NARCIS (Netherlands)

    Zimmermann, M.B.; Hurrell, R.F.

    2007-01-01

    Iron deficiency is one of the leading risk factors for disability and death worldwide, affecting an estimated 2 billion people. Nutritional iron deficiency arises when physiological requirements cannot be met by iron absorption from diet. Dietary iron bioavailability is low in populations consuming

  14. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Topics section only, or the News and Resources section. NHLBI Entire Site NHLBI Entire Site Health ... español Iron-deficiency anemia is a common type of anemia that occurs if you do not have enough iron in your body. People with mild or moderate iron-deficiency anemia ...

  15. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... for iron-deficiency anemia. Lifestyle habits Certain lifestyle habits may increase your risk for iron-deficiency anemia, including: Vegetarian or vegan eating patterns. Not eating enough iron-rich foods, such as meat and fish, may result in ...

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... blood cells. Iron-deficiency anemia usually develops over time because your body’s intake of iron is too ... clamping of your newborn’s umbilical cord at the time of delivery. This may help prevent iron-deficiency ...

  17. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... other conditions that can cause iron-deficiency anemia. Blood tests to screen for iron-deficiency anemia To screen ... check the size of your liver and spleen. Blood tests Based on results from blood tests to screen ...

  18. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... also are hoping to determine which iron supplements work best to treat iron-deficiency anemia in children who do not consume the daily recommended amount of iron. Read less Participate in NHLBI Clinical Trials We lead or sponsor many studies related to iron-deficiency anemia. See if you ...

  19. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... en español Iron-deficiency anemia is a common type of anemia that occurs if you do not ... iron-deficiency anemia and help rule out other types of anemia. Treatment will explain treatment-related complications ...

  20. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... anemia. Return to Signs, Symptoms, and Complications to review signs and symptoms as well as complications from iron-deficiency ... NIH]) Heavy Menstrual Bleeding (Centers for Disease Control and ... Dietary Supplement Fact Sheet (NIH) Iron-Deficiency Anemia (National Library ...

  1. Iron deficiency anemia

    Science.gov (United States)

    Anemia - iron deficiency ... iron from old red blood cells. Iron deficiency anemia develops when your body's iron stores run low. ... You may have no symptoms if the anemia is mild. Most of the time, ... slowly. Symptoms may include: Feeling weak or tired more often ...

  2. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... be at risk for iron-deficiency anemia. Lifestyle habits Certain lifestyle habits may increase your risk for iron-deficiency anemia, ... you are experiencing side effects such as a bad metallic taste, vomiting, diarrhea, constipation, or upset stomach. ...

  3. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... how we are using current research and advancing research to prevent iron-deficiency anemia. Participate in NHLBI Clinical Trials will explain our ongoing clinical studies that are investigating prevention strategies for iron-deficiency anemia. Signs, Symptoms, and Complications ...

  4. Self-assembled dopamine nanolayers wrapped carbon nanotubes as carbon-carbon bi-functional nanocatalyst for highly efficient oxygen reduction reaction and antiviral drug monitoring

    Science.gov (United States)

    Khalafallah, Diab; Akhtar, Naeem; Alothman, Othman Y.; Fouad, H.; Abdelrazek khalil, Khalil

    2017-09-01

    Oxygen reduction reaction (ORR) catalysts are the heart of eco-friendly energy resources particularly low temperature fuel cells. Although valuable efforts have been devoted to synthesize high performance catalysts for ORR, considerable challenges are extremely desirable in the development of energy technologies. Herein, we report a simple self-polymerization method to build a thin film of dopamine along the tubular nanostructures of multi-walled carbon nanotubes (CNT) in a weak alkaline solution. The dopamine@CNT hybrid (denoted as DA@CNT) reveals an enhanced electrocatalytic activity towards ORR with highly positive onset potential and cathodic current as a result of their outstanding features of longitudinal mesoporous structure, high surface area, and ornamentation of DA layers with nitrogen moieties, which enable fast electron transport and fully exposed electroactive sites. Impressively, the as-obtained hybrid afford remarkable electrochemical durability for prolonged test time of 60,000 s compared to benchmark Pt/C (20 wt%) catalyst. Furthermore, the developed DA@CNT electrode was successfully applied to access the quality of antiviral drug named Valacyclovir (VCR). The DA@CNT electrode shows enhanced sensing performance in terms of large linear range (3-75 nM), low limit of detection (2.55 nM) than CNT based electrode, indicating the effectiveness of the DA coating. Interestingly, the synergetic effect of nanostructured DA and CNT can significantly boost the electronic configuration and exposure level of active species for ORR and biomolecule recognition. Therefore, the existing carbon-based porous electrocatalyst may find numerous translational applications as attractive alternative to noble metals in polymer electrolyte membrane fuel cells and quality control assessment of pharmaceutical and therapeutic drugs.

  5. Ensuring effective prevention of iodine-deficiency disorders

    DEFF Research Database (Denmark)

    Völzke, Henry; Caron, Philippe Jean; Dahl, Lisbeth

    2016-01-01

    BACKGROUND: Programs initiated to prevent iodine deficiency disorders (IDD) may not remain effective due to changes in government policies, commercial factors, and human behavior that may affect the efficacy of IDD prevention programs in unpredictable directions. Monitoring and outcome studies...... by the lack of centralized standardization procedures. In addition, data on outcomes and the cost of achieving them are needed in order to provide evidence of the beneficial effects of IDD prevention in countries with mild iodine deficiency. CONCLUSION: Monitoring studies can be optimized by including...... in mildly iodine-deficient areas and that it should include populations from regions with different environmental, ethnic, and cultural backgrounds....

  6. Vitamin B12 deficiency

    DEFF Research Database (Denmark)

    Green, Ralph; Allen, Lindsay H; Bjørke-Monsen, Anne-Lise

    2017-01-01

    , subclinical deficiency affects between 2.5% and 26% of the general population depending on the definition used, although the clinical relevance is unclear. B12 deficiency can affect individuals at all ages, but most particularly elderly individuals. Infants, children, adolescents and women of reproductive age...... remain debated. Management depends on B12 supplementation, either via high-dose oral routes or via parenteral administration. This Primer describes the current knowledge surrounding B12 deficiency, and highlights improvements in diagnostic methods as well as shifting concepts about the prevalence, causes...

  7. The spectral invariant approximation within canopy radiative transfer to support the use of the EPIC/DSCOVR oxygen B-band for monitoring vegetation

    International Nuclear Information System (INIS)

    Marshak, Alexander; Knyazikhin, Yuri

    2017-01-01

    EPIC (Earth Polychromatic Imaging Camera) is a 10-channel spectroradiometer onboard DSCOVR (Deep Space Climate Observatory) spacecraft. In addition to the near-infrared (NIR, 780 nm) and the ‘red’ (680 nm) channels, EPIC also has the O2 A-band (764±0.2 nm) and B-band (687.75±0.2 nm). The EPIC Normalized Difference Vegetation Index (NDVI) is defined as the difference between NIR and ‘red’ channels normalized to their sum. However, the use of the O2 B-band instead of the ‘red’ channel mitigates the effect of atmosphere on remote sensing of surface reflectance because O2 reduces contribution from the radiation scattered by the atmosphere. Applying the radiative transfer theory and the spectral invariant approximation to EPIC observations, the paper provides supportive arguments for using the O2 band instead of the red channel for monitoring vegetation dynamics. Our results suggest that the use of the O2 B-band enhances the sensitivity of the top-of-atmosphere NDVI to the presence of vegetation. - Highlights: • The use of the O2 B-band channel (688 nm) instead of the red channel (680 nm) mitigates the effect of atmosphere on remote sensing of surface reflectance. • The spectral invariant approach confirms that the synergy of the green, O2 B-band and near IR channels mimics spectral properties of vegetation. • The structural parameter of vegetation retrieved remotely is weakly sensitive to the uncertainty in the atmospheric optical depth.

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... body to absorb iron from the gastrointestinal tract (GI tract). Blood loss When you lose blood, you ... to iron-deficiency anemia include: Bleeding in your GI tract, from an ulcer, colon cancer, or regular ...

  9. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... for gastrointestinal bleeding To see if gastrointestinal bleeding is causing your iron-deficiency anemia, your doctor may order the following procedures to guide treatment . Fecal ...

  10. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... complications, including heart failure and development delays in children. Explore this Health ... red blood cells. Iron-deficiency anemia usually develops over time because your body’s intake of iron ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Supplement Fact Sheet (NIH) Iron-Deficiency Anemia (National Library of Medicine, MedlinePlus) ... Privacy Policy Freedom of Information Act (FOIA) Accessibility Copyright and Usage No FEAR ...

  12. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... our clinical trials . Are you a frequent blood donor living in New York City? This study is looking at how iron-deficiency anemia in blood donors affects the quality of donated red blood cells, ...

  13. Vitamin D Deficiency

    Science.gov (United States)

    ... to other diseases. In children, it can cause rickets. Rickets is a rare disease that causes the bones ... and children are at higher risk of getting rickets. In adults, severe vitamin D deficiency leads to ...

  14. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Health and Human Development, we are investigating how best to treat premature newborns with low hemoglobin levels. ... are hoping to determine which iron supplements work best to treat iron-deficiency anemia in children who ...

  15. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget and Legislative Information Jobs and ... may recommend you eat heart-healthy foods or control other conditions that can cause iron-deficiency anemia. ...

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia may cause the following complications: Depression Heart problems. If you do not have enough ... these usually go away within a day or two. Red blood cell transfusions. These may be used ...

  17. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... more. Read less Reminders Return to Causes to review how blood loss, not consuming the recommended amount ... iron-deficiency anemia. Return to Risk Factors to review family history, lifestyle, unhealthy environments, or other factors ...

  18. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... same for boys and girls. From birth to 6 months, babies need 0.27 mg of iron. ... for iron deficiency at certain ages: Infants between 6 and 12 months, especially if they are fed ...

  19. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... detect signs of iron-deficiency anemia and help rule out other types of anemia. Treatment will explain ... your blood. More testing may be needed to rule out other types of anemia. Tests for gastrointestinal ...

  20. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... red blood cells, called hemolysis . Hemolysis, in this case, is caused by strong muscle contractions and the ... to prevent iron-deficiency anemia. Participate in NHLBI Clinical Trials will explain our ongoing clinical studies that ...

  1. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... to improve health through research and scientific discovery. Improving health with current research Learn about the following ... deficiency anemia early in life affects later behavior, thinking, and mood during adolescence. Treating anemia in premature ...

  2. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... A-Z Clinical Trials Publications and Resources Health Education and Awareness ... If your doctor diagnoses you with iron-deficiency anemia, your treatment will depend on the cause and severity of the condition. Your ...

  3. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... your blood may be normal even if the total amount of iron in your body is low. ... iron-deficiency anemia in blood donors affects the quality of donated red blood cells, such as how ...

  4. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... interferes with the body’s ability to make hemoglobin. Family history and genetics Von Willebrand disease is an ... deficiency anemia. Return to Risk Factors to review family history, lifestyle, unhealthy environments, or other factors that ...

  5. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... diagnoses you with iron-deficiency anemia, your treatment will depend on the cause and severity of the ... of iron. The recommended daily amounts of iron will depend on your age, sex, and whether you ...

  6. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... from developing iron-deficiency anemia. Foods that are good sources of iron include dried beans, dried fruits, ... iron is needed, such as childhood and pregnancy. Good sources of iron are meat, poultry, fish, and ...

  7. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... A-Z Clinical Trials Publications and Resources Health Education and Awareness The Science Science Home Blood Disorders ... infancy has lasting effects. We are interested in learning how having iron-deficiency anemia early in life ...

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... heart failure . Increased risk of infections Motor or cognitive development delays in children Pregnancy complications, such as ... iron-deficiency anemia may require intravenous (IV) iron therapy or a blood transfusion . Iron supplements Your doctor ...

  9. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... absorb iron and lead to iron-deficiency anemia. These conditions include: Intestinal and digestive conditions, such as ... tract. Inflammation from congestive heart failure or obesity . These chronic conditions can lead to inflammation that may ...

  10. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Blood Disorders and Blood Safety Sleep Science and Sleep Disorders Lung Diseases Heart and Vascular Diseases Precision Medicine ... prevention and treatment of heart, lung, blood, and sleep disorders, including iron-deficiency anemia. Learn about the current ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia early in life affects later behavior, thinking, and mood during adolescence. Treating anemia in ... Visit Children and Clinical Studies to hear experts, parents, and children talk about their experiences with clinical ...

  12. Factor V deficiency

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000550.htm Factor V deficiency To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  13. Factor II deficiency

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000549.htm Factor II deficiency To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  14. Factor X deficiency

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000553.htm Factor X deficiency To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  15. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... is caused by strong muscle contractions and the impact of feet repeatedly striking the ground, such as ... funding on iron-deficiency anemia. We stimulate high-impact research. Our Trans-Omics for Precision Medicine (TOPMed) ...

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... may be diagnosed with iron-deficiency anemia if you have low iron or ferritin levels in your blood. More testing may be needed to rule out other types of anemia. Tests for gastrointestinal ...

  17. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... for your body to absorb iron from the gastrointestinal tract (GI tract). Blood loss When you lose blood, ... iron deficiency. Endurance athletes lose iron through their gastrointestinal tracts. They also lose iron through the breakdown of ...

  18. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... vegetables. Foods rich in vitamin C, such as oranges, strawberries, and tomatoes, may help increase your absorption ... deficiency anemia, your doctor may recommend erythropoiesis stimulating agents (esa) . These medicines stimulate the bone marrow to ...

  19. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... were born prematurely may be at an even higher risk, as most of a newborn’s iron stores ... men of the same age. Women are at higher risk for iron-deficiency anemia under some circumstances, ...

  20. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Iron-Deficiency Anemia (National Library of Medicine, MedlinePlus) Building 31 31 Center Drive Bethesda, MD 20892 Learn ... and Usage No FEAR Act Grants and Funding Building 31 31 Center Drive Bethesda, MD 20892 Learn ...

  1. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... may recommend erythropoiesis stimulating agents (esa) . These medicines stimulate the bone marrow to make more red blood ... NHLBI is funding on iron-deficiency anemia. We stimulate high-impact research. Our Trans-Omics for Precision ...

  2. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... tests, especially in infants and small children Heavy menstrual periods Injury or surgery Urinary tract bleeding Consuming ... iron-deficiency anemia from trauma, surgery, or heavy menstrual periods. Individuals with a gene for hemophilia, including ...

  3. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... and naproxen Certain rare genetic conditions such as hereditary hemorrhagic telangiectasia, which causes bleeding in the bowels ... iron-deficiency anemia may cause the following complications: Depression Heart problems. If you do not have enough ...

  4. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... lead in their blood from their environment or water. Lead interferes with the body’s ability to make ... iron-deficiency anemia in blood donors affects the quality of donated red blood cells, such as how ...

  5. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... also often take other medicines—such as proton pump inhibitors, anticoagulants, or blood thinners—that may cause iron-deficiency anemia. Proton pump inhibitors interfere with iron absorption, and blood thinners ...

  6. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Cells From Iron-deficient Donors: Recovery and Storage Quality. Learn more about participating in a clinical trial . View all trials from ClinicalTrials.gov . Visit Children and Clinical Studies to hear experts, parents, and ...

  7. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Look for Treatment will discuss medicines and eating pattern changes that your doctors may recommend if you ... iron-deficiency anemia, including: Vegetarian or vegan eating patterns. Not eating enough iron-rich foods, such as ...

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... girls. From birth to 6 months, babies need 0.27 mg of iron. This number goes up ... screen blood donors for low iron stores. Reliable point-of-care testing may help identify iron deficiency ...

  9. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... striking the ground, such as with marathon runners. Sex Girls and women between the ages of 14 ... developing iron-deficiency anemia. Foods that are good sources of iron include dried beans, dried fruits, eggs, ...

  10. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... increase your risk for iron-deficiency anemia, including: Vegetarian or vegan eating patterns. Not eating enough iron- ... factors , such as if you are following a vegetarian eating pattern, your doctor may recommend changes to ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... deficiency anemia. Proton pump inhibitors interfere with iron absorption, and blood thinners increase the likelihood of bleeding ... oranges, strawberries, and tomatoes, may help increase your absorption of iron. If you are pregnant, talk to ...

  12. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... screen for iron-deficiency anemia, your doctor may order a blood test called a complete blood count ( ... your risk factors , do a physical exam, or order blood tests or other diagnostic tests. Physical exam ...

  13. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... duodenum, the first part of the small intestine just beyond the stomach. Even if you have enough ... clamping of your newborn’s umbilical cord at the time of delivery. This may help prevent iron-deficiency ...

  14. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... less than 12 g/dl for women is diagnostic of anemia. In iron-deficiency anemia, red blood ... both full-term and preterm infants. Look for Diagnosis will explain tests and procedures that your doctor ...

  15. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... less than 12 g/dl for women is diagnostic of anemia. In iron-deficiency anemia, red blood ... physical exam, or order blood tests or other diagnostic tests. Physical exam Your doctor may ask about ...

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... risk for iron-deficiency anemia, including: Vegetarian or vegan eating patterns. Not eating enough iron-rich foods, ... iron-fortified foods that have iron added. Vegetarian diets can provide enough iron if you choose nonmeat ...

  17. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... bleeding. If undiagnosed or untreated, iron-deficiency anemia can cause serious complications, including heart failure and development ... iron is too low. Low intake of iron can happen because of blood loss, consuming less than ...

  18. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... improved health for people with iron-deficiency anemia. Recipient Epidemiology Donor Studies program findings help to protect blood donors . NHLBI’s Recipient Epidemiology Donor Studies (REDS) program , which began in ...

  19. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... a frequent blood donor living in New York City? This study is looking at how iron-deficiency ... frequently. This study is located in New York City, and is recruiting by invitation only. View more ...

  20. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... to 11 mg for children ages 7 to 12 months, and down to 7 mg for children ... deficiency at certain ages: Infants between 6 and 12 months, especially if they are fed only breast ...

  1. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... in our clinical trials . Are you a frequent blood donor living in New York City? This study is looking at how iron-deficiency anemia in blood donors affects the quality of donated red blood cells, ...

  2. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia may cause the following complications: Depression Heart problems. If you do not have enough ... prevent complications such as abnormal heart rhythms and depression. Learn the warning signs of serious complications and ...

  3. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... prevent complications such as abnormal heart rhythms and depression. Learn the warning signs of serious complications and ... donors for low iron stores. Reliable point-of-care testing may help identify iron deficiency before potentially ...

  4. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... be at risk for iron-deficiency anemia. Lifestyle habits Certain lifestyle habits may increase your risk for ... Surgery, upper endoscopy or colonoscopy, to stop bleeding. Healthy lifestyle changes To help you meet your daily ...

  5. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... breastfeeding women older than 18 need 9 mg. Problems absorbing iron Even if you consume the recommended ... interested in learning how having iron-deficiency anemia early in life affects later behavior, thinking, and mood ...

  6. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... starch. Restless legs syndrome Shortness of breath Weakness Complications Undiagnosed or untreated iron-deficiency anemia may cause ... as complete blood count and iron studies. Prevent complications over your lifetime To prevent complications from iron- ...

  7. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... you do not have enough iron in your body. People with mild or moderate iron-deficiency anemia ... and where to find more information. Causes Your body needs iron to make healthy red blood cells. ...

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia. Learn about the current and future NHLBI efforts to improve health through research and ... blood donors. Cardiovascular Health Study identifies predictors of future health problems in older adults. The NHLBI-sponsored ...

  9. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... as most of a newborn’s iron stores are developed during the third trimester of pregnancy. Children between ... This makes it harder to stop bleeding and can increase the risk of iron-deficiency anemia from ...

  10. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... an MCV of less than 80 femtoliters (fL). Prevention strategies If you have certain risk factors , such ... explain our ongoing clinical studies that are investigating prevention strategies for iron-deficiency anemia. Signs, Symptoms, and ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Safety Sleep Science and Sleep Disorders Lung Diseases Heart and Vascular Diseases Precision Medicine Activities Obesity, Nutrition, ... iron-deficiency anemia can cause serious complications, including heart failure and development delays in children. Explore this ...

  12. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... symptoms. More severe iron-deficiency anemia may cause fatigue or tiredness, shortness of breath, or chest pain. ... in the hands and feet Difficulty concentrating Dizziness Fatigue, or feeling tired, is the most common symptom. ...

  13. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... to learn more about iron-deficiency anemia, our role in research and clinical trials to improve health, ... of Blood Diseases and Resources (DBDR) is a leader in research on the causes, prevention, and treatment ...

  14. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Treatment will explain treatment-related complications or side effects. Diagnosis Iron-deficiency anemia may be detected during ... to your doctor if you are experiencing side effects such as a bad metallic taste, vomiting, diarrhea, ...

  15. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... an increased risk for iron-deficiency anemia because of your age, unhealthy environments, family ... 12 months, especially if they are fed only breast milk or are fed formula that is not fortified ...

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... blood tests, especially in infants and small children Heavy menstrual periods Injury or surgery Urinary tract bleeding ... of iron-deficiency anemia from trauma, surgery, or heavy menstrual periods. Individuals with a gene for hemophilia, ...

  17. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... developing iron-deficiency anemia. Foods that are good sources of iron include dried beans, dried fruits, eggs, ... is needed, such as childhood and pregnancy. Good sources of iron are meat, poultry, fish, and iron- ...

  18. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Individuals with a gene for hemophilia, including symptomatic female carriers who have heavy menstrual periods, may be ... anemia. Endurance activities and athletes. Athletes, especially young females, are at risk for iron deficiency. Endurance athletes ...

  19. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... and Strategic Vision Leadership Scientific Divisions Operations and Administration Advisory Committees Budget and Legislative Information Jobs and ... blood cells. Iron-deficiency anemia usually develops over time because your body’s intake of iron is too ...

  20. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... MCV of less than 80 femtoliters (fL). Prevention strategies If you have certain risk factors , such as ... our ongoing clinical studies that are investigating prevention strategies for iron-deficiency anemia. Signs, Symptoms, and Complications ...

  1. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... may recommend you eat heart-healthy foods or control other conditions that can cause iron-deficiency anemia. ... heavy menstrual bleeding, your doctor will want to control these other conditions to prevent you from developing ...

  2. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... lead to iron-deficiency anemia include: End-stage kidney failure, where there is blood loss during dialysis. People who have chronic kidney disease also often take other medicines—such as ...

  3. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... may be at risk for iron-deficiency anemia. Lifestyle habits Certain lifestyle habits may increase your risk ... upper endoscopy or colonoscopy, to stop bleeding. Healthy lifestyle changes To help you meet your daily recommended ...

  4. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... endoscopy or colonoscopy, to stop bleeding. Healthy lifestyle changes To help you meet your daily recommended iron ... iron-deficiency anemia early in life affects later behavior, thinking, and mood during adolescence. Treating anemia in ...

  5. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Chest pain Coldness in the hands and feet Difficulty concentrating Dizziness Fatigue, or feeling tired, is the ... Our support of SBIR/STTR programs is helping advance research in iron-deficiency anemia, in part by ...

  6. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... infancy has lasting effects. We are interested in learning how having iron-deficiency anemia early in life ... Customer Service/Center for Health Information Email Alerts Jobs and Careers Site Index About NHLBI National Institute ...

  7. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... family history and genetics , lifestyle habits, or sex. Age You may be at increased risk for iron ... Signs, Symptoms, and Complications Iron-deficiency anemia can range from mild to severe. People with mild or ...

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron to prepare for blood loss during delivery. Screening and Prevention Your doctor may screen you for ... and symptoms of iron-deficiency anemia. Return to Screening and Prevention to review tests to screen for ...

  9. Oxygen status during haemodialysis. The Cord-Group

    DEFF Research Database (Denmark)

    Nielsen, A L; Jensen, H Æ; Hegbrant, J

    1995-01-01

    Hypoxia during haemodialysis, mainly acetate, has been reported several times. In our study we have monitored oxygen status during 258 bicarbonate haemodialyses. A significant drop below 80 mmHg in mean oxygen tension occurred. Mean oxygen saturation reflected this drop but did not reach levels...... below 90%. The mean oxygen concentration was on the whole critical low, though slightly increasing during each haemodialysis session due to ultrafiltration. It is concluded that both hypoxia and hypoxaemia do occur during bicarbonate haemodialysis. To a group of patients generally having limited cardiac...... reserves, a poor oxygen status is a potentially serious complication to haemodialysis. Monitoring oxygen status is thus advisable....

  10. Cooking and oxygen. An explosive recipe.

    Science.gov (United States)

    Burns, H L; Ralston, D; Muller, M; Pegg, S

    2001-02-01

    Home oxygen therapy is commonly prescribed for the treatment of chronic obstructive pulmonary disease (COPD). The risks of smoking while using this therapy have been well described. To discuss the Royal Brisbane Hospital Burns Unit's experience and present case studies which illustrate the danger of alternative ignition sources while using home oxygen. The dangers of home oxygen therapy can be minimised by careful patient selection, education and ongoing monitoring.

  11. Oxygen activity measurements in simulated converter matte

    CSIR Research Space (South Africa)

    Tshilombo, KG

    2007-01-01

    Full Text Available to the composition of the gas atmosphere over the melt. The measured oxygen activity was generally close to that predicted by FactSage calculations. This indicates that such oxygen activity measurements could be useful to monitor iron removal during converting...

  12. [Iron deficiency and pica].

    Science.gov (United States)

    Muñoz, J A; Marcos, J; Risueño, C E; de Cos, C; López, R; Capote, F J; Martín, M V; Gil, J L

    1998-02-01

    To study the relationship between pica and iron-lack anaemia in a series of iron-deficiency patients in order to establish the pathogenesis of such relationship. Four-hundred and thirty-three patients were analysed. Pica was studied by introducing certain diet queries into the clinical history. All patients received oral iron and were periodically controlled with the usual clinico-haematological procedures. Pica was present in 23 patients (5.3%). Eight nourishing (namely, coffee grains, almonds, chocolate, ice, lettuce, carrots, sunflower seeds and bread) and 2 non-nourishing (clay and paper) substances were involved. A second episode of pica appeared in 9 cases upon relapsing of iron deficiency. Both anaemia and pica were cured by etiologic and substitutive therapy in all instances. No clear correlation was found with either socio-economic status or pathogenetic causes of iron deficiency and pica, and no haematological differences were seen between patients with pica and those without this alteration. (1) The pathogenesis of pica is unclear, although it appears unrelated to the degree of iron deficiency. (2) According to the findings in this series, pica seems a consequence of iron deficiency rather than its cause. (3) Adequate therapy can cure both conditions, although pica may reappear upon relapse of iron deficiency.

  13. Hypoxia, Color Vision Deficiencies, and Blood Oxygen Saturation

    Science.gov (United States)

    2013-11-01

    using the Dvorine Pseudoisochromatic Plate Test (2nd edition, Psychological Corporation, Baltimore, MD) illuminated by True Daylight Illuminator T8...Plant, G.T. (1994). Insights into the different exploits of colour in the visual cortex. Proc Biol Sci, 258 (1353), 327-334. Barbur, J.L...Aviat Space Environ Med, 80, 933-940. Crow, T.J.,& Kelman, G.R.(1973). Psychological effects of mild acute hypoxia. Br J Anaesth, 45, 335-337

  14. Hypoxia, color vision deficiencies, and blood oxygen saturation.

    Science.gov (United States)

    2013-11-01

    Chromatic thresholds were measured using the Cambridge Color Test (CCT), Color Assessment and Diagnosis : (CAD) test, and Cone Specific Contrast Test at ground and 3780 m (12,400 ft) for subjects with normal color : vision and red-green color vision ...

  15. Circadian behaviour in neuroglobin deficient mice.

    Directory of Open Access Journals (Sweden)

    Christian A Hundahl

    Full Text Available Neuroglobin (Ngb, a neuron-specific oxygen-binding globin with an unknown function, has been proposed to play a key role in neuronal survival. We have previously shown Ngb to be highly expressed in the rat suprachiasmatic nucleus (SCN. The present study addresses the effect of Ngb deficiency on circadian behavior. Ngb-deficient and wild-type (wt mice were placed in running wheels and their activity rhythms, endogenous period and response to light stimuli were investigated. The effect of Ngb deficiency on the expression of Period1 (Per1 and the immediate early gene Fos was determined after light stimulation at night and the neurochemical phenotype of Ngb expressing neurons in wt mice was characterized. Loss of Ngb function had no effect on overall circadian entrainment, but resulted in a significantly larger phase delay of circadian rhythm upon light stimulation at early night. A light-induced increase in Per1, but not Fos, gene expression was observed in Ngb-deficient mice. Ngb expressing neurons which co-stored Gastrin Releasing Peptide (GRP and were innervated from the eye and the geniculo-hypothalamic tract expressed FOS after light stimulation. No PER1 expression was observed in Ngb-positive neurons. The present study demonstrates for the first time that the genetic elimination of Ngb does not affect core clock function but evokes an increased behavioural response to light concomitant with increased Per1 gene expression in the SCN at early night.

  16. Relationship Between Cerebral Oxygenation and Hemodynamic and Oxygen Transport Parameters in Surgery for Acquired Heart Diseases

    Directory of Open Access Journals (Sweden)

    A. I. Lenkin

    2012-01-01

    Full Text Available Objective: to evaluate the relationship between cerebral oxygenation and hemodynamic and oxygen transport parameters in surgical correction of concomitant acquired heart diseases. Subjects and methods. Informed consent was received from 40 patients who required surgery because of concomitant (two or more acquired heart defects. During procedure, perioperative monitoring of oxygen transport and cerebral oxygenation was performed with the aid of PiCCO2 monitor (Pulsion Medical Systems, Germany and a Fore-Sight cerebral oximeter (CASMED, USA. Anesthesia was maintained with propofol and fen-tanyl, by monitoring the depth of anesthesia. Early postoperative intensive therapy was based on the protocol for early targeted correction of hemodynamic disorders. Oxygen transport and cerebral oxygenation parameters were estimated intraopera-tively and within 24 postoperative hours. A statistical analysis including evaluation of Spearman correlations was performed with the aid of SPSS 15.0. Results. During perfusion, there was a relationship between cerebral oximetry values and hemat-ocrit levels, and oxygen partial pressure in the venous blood. Furthermore, a negative correlation between cerebral oximetry values and blood lactate levels was found 30 minutes after initiation of extracorporeal circulation (EC. During the study, there was a positive correlation between cerebral oxygenation and values of cardiac index, central venous saturation, and oxygen delivery index. There was a negative relationship between cerebral oxygenation and extravascular lung water at the beginning of surgery and a correlation between cerebral oximetry values and oxygenation index by the end of the first 24 postoperative hours. Conclusion. The cerebral oxygenation values correlate -with the main determinants of oxygen transport during EC and after cardiac surgical procedures. Cerebral oximetry may be used in early targeted therapy for the surgical correction of acquired combined

  17. Identification and quantification of nitrogen nutrient deficiency in the activated sludge process using respirometry

    NARCIS (Netherlands)

    Ning, Z.; Patry, G.G.; Spanjers, H.

    2000-01-01

    Experimental protocols to identify and quantify nitrogen nutrient deficiency in the activated sludge process were developed and tested using respirometry. Respirometric experiments showed that when a nitrogen nutrient deficient sludge is exposed to ammonia nitrogen, the oxygen uptake rate (OUR) of

  18. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... normal. Hemoglobin is a protein inside red blood cells that carries oxygen from the lungs to tissues and organs in ... to work well. Normally, hemoglobin in red blood cells takes up oxygen in the lungs and carries it to all ...

  19. prevalence of iron deficiency in children with cyanotic heart disease

    African Journals Online (AJOL)

    2009-12-01

    Dec 1, 2009 ... ... bone marrow to produce more red cells in an effort to increase the body's oxygen ... so the production of more and more red cells goes unabated leading to ... of iron deficiency was calculated as proportion of children with ...

  20. Noninvasive assessment of tissue-engineered graft viability by oxygen-17 magnetic resonance spectroscopy.

    Science.gov (United States)

    Einstein, Samuel A; Weegman, Bradley P; Kitzmann, Jennifer P; Papas, Klearchos K; Garwood, Michael

    2017-05-01

    Transplantation of macroencapsulated tissue-engineered grafts (TEGs) is being investigated as a treatment for type 1 diabetes, but there is a critical need to measure TEG viability both in vitro and in vivo. Oxygen deficiency is the most critical issue preventing widespread implementation of TEG transplantation and delivery of supplemental oxygen (DSO) has been shown to enhance TEG survival and function in vivo. In this study, we demonstrate the first use of oxygen-17 magnetic resonance spectroscopy ( 17 O-MRS) to measure the oxygen consumption rate (OCR) of TEGs and show that in addition to providing therapeutic benefits to TEGs, DSO with 17 O 2 can also enable measurements of TEG viability. Macroencapsulated TEGs containing βTC3 murine insulinoma cells were prepared with three fractional viabilities and provided with 17 O 2 . Cellular metabolism of 17 O 2 into nascent mitochondrial water (H 2 17 O) was monitored by 17 O-MRS and, from the measured data, OCR was calculated. For comparison, OCR was simultaneously measured on a separate, but equivalent sample of cells with a well-established stirred microchamber technique. OCR measured by 17 O-MRS agreed well with measurements made in the stirred microchamber device. These studies confirm that 17 O-MRS can quantify TEG viability noninvasively. Biotechnol. Bioeng. 2017;114: 1118-1121. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Progression from isolated growth hormone deficiency to combined pituitary hormone deficiency.

    Science.gov (United States)

    Cerbone, Manuela; Dattani, Mehul T

    2017-12-01

    Growth hormone deficiency (GHD) can present at any time of life from the neonatal period to adulthood, as a result of congenital or acquired insults. It can present as an isolated problem (IGHD) or in combination with other pituitary hormone deficiencies (CPHD). Pituitary deficits can evolve at any time from GHD diagnosis. The number, severity and timing of occurrence of additional endocrinopathies are highly variable. The risk of progression from IGHD to CPHD in children varies depending on the etiology (idiopathic vs organic). The highest risk is displayed by children with abnormalities in the Hypothalamo-Pituitary (H-P) region. Heterogeneous data have been reported on the type and timing of onset of additional pituitary hormone deficits, with TSH deficiency being most frequent and Diabetes Insipidus the least frequent additional deficit in the majority, but not all, of the studies. ACTH deficiency may gradually evolve at any time during follow-up in children or adults with childhood onset IGHD, particularly (but not only) in presence of H-P abnormalities and/or TSH deficiency. Hence there is a need in these patients for lifelong monitoring for ACTH deficiency. GH treatment unmasks central hypothyroidism mainly in patients with organic GHD, but all patients starting GH should have their thyroid function monitored closely. Main risk factors for development of CPHD include organic etiology, H-P abnormalities (in particular pituitary stalk abnormalities, empty sella and ectopic posterior pituitary), midline brain (corpus callosum) and optic nerves abnormalities, genetic defects and longer duration of follow-up. The current available evidence supports longstanding recommendations for the need, in all patients diagnosed with IGHD, of a careful and indefinite follow-up for additional pituitary hormone deficiencies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Antepartum Ornithine Transcarbamylase Deficiency

    Directory of Open Access Journals (Sweden)

    Hitoshi Nakajima

    2014-11-01

    Full Text Available Ornithine transcarbamylase deficiency (OTCD is the most common type urea cycle enzyme deficiencies. This syndrome results from a deficiency of the mitochondrial enzyme ornithine transcarbamylase, which catalyzes the conversion of ornithine and carbamoyl phosphate to citrullin. Our case was a 28-year-old female diagnosed with OTCD following neurocognitive deficit during her first pregnancy. Although hyperammonemia was suspected as the cause of the patient's mental changes, there was no evidence of chronic liver disease. Plasma amino acid and urine organic acid analysis revealed OTCD. After combined modality treatment with arginine, sodium benzoate and hemodialysis, the patient's plasma ammonia level stabilized and her mental status returned to normal. At last she recovered without any damage left.

  3. Oxygen diffusion in bilayer polymer films

    DEFF Research Database (Denmark)

    Poulsen, Lars; Zebger, Ingo; Tofte, Jannik Pentti

    2004-01-01

    Experiments to quantify oxygen diffusion have been performed on polymer samples in which a film of poly(ethylene-co-norbornene) was cast onto a film of polystyrene which, in turn, was cast onto an oxygen-impermeable substrate. In the technique employed, the time evolution of oxygen transport...... through the film of poly(ethylene-co-norbornene) and into the polystyrene film was monitored using the phosphorescence of singlet oxygen as a spectroscopic probe. To analyze the data, it was necessary to solve Fick's second law of diffusion for both polymer films. Tractable analytical and numerical...

  4. Vitamin Excess and Deficiency.

    Science.gov (United States)

    Diab, Liliane; Krebs, Nancy F

    2018-04-01

    The published literature supports the high prevalence of supplement use in children and adolescents in the United States. Pediatricians today are faced with questions from parents and patients about the benefits, safety, efficacy, and correct dose of vitamins and minerals. In this article, we review 7 vitamins with the most clinical relevance as judged by abundance in food, risks and symptoms of deficiency, and potential for toxicity. Specifically, we focus on possible clinical scenarios that can be indicative of nutritional deficiency. We synthesize and summarize guidelines from nutrition experts, various medical societies, the World Health Organization, and the American Academy of Pediatrics. © American Academy of Pediatrics, 2018. All rights reserved.

  5. Rhizosphere dynamics of two riparian plant species from the water fluctuation zone of Three Gorges Reservoir, P.R. China - pH, oxygen and LMWOA monitoring during short flooding events

    Science.gov (United States)

    Schreiber, Christina M.; Schurr, Ulrich; Zeng, Bo; Höltkemeier, Agnes; Kuhn, Arnd J.

    2010-05-01

    Since the construction of the Three Gorges Dam at the Yangtze River in China, the reservoir management created a new 30m water fluctuation zone 45-75m above the original water level. Only species well adapted to long-time flooding (up to several months) will be able to vegetate the river banks and replace the original vegetation. To investigate how common species of the riverbanks cope with submergence, Alternanthera philoxeroides Mart. and Arundinella anomala Steud., two flooding resistant riparian species, have been examined in a rhizotron environment. Short-time (2 days waterlogging, 2 days flooding, 2 days recovery) flooding cycles in the original substrate and long time (14 days waterlogging, flooding, recovery) flooding cycles, in original substrate and sterile glass bead substrate, have been simulated in floodable two-way access rhizotrons. Oxygen- and pH-sensitive foils (planar optodes, PreSens) automatically monitored root reaction in a confined space (2cm2 each) on the backside of the rhizotron, while soil solution samples were taken 2 times a day from the other side of the rhizotron at the corresponding area through filter and steel capillaries. The samples were analyzed by capillary electrophoresis for low molecular weight organic acids (LMWOA, i.e. oxalic, formic, succinic, malic, acetic, glyoxylic, lactic and citric acid). Results show diurnal rhythms of rhizospheric acidification for both species in high resolution, combined with oxygen entry into the root surrounding during waterlogged state. Flooding caused stronger acidification in the rhizosphere, that were however not accompanied by increased occurrence of LMWOA except for acetic and glyoxylic acid. First results from longer flooding periods show stable diurnal rhythms during waterlogging, but no strongly increased activity during the flooding event. Performance of the two species is not hampered by being waterlogged, and they follow a silencing strategy during a longer phase of anoxia without

  6. SSV Launch Monitoring Strategies: HGDS Design Implementation Through System Maturity

    Science.gov (United States)

    Shoemaker, Marc D.; Crimi, Thomas

    2010-01-01

    With over 500,000 gallons of liquid hydrogen and liquid oxygen, it is of vital importance to monitor the space shuttle vehicle (SSV) from external tank (ET) load through launch. The Hazardous Gas Detection System (HGDS) was installed as the primary system responsible for monitoring fuel leaks within the orbiter and ET. The HGDS was designed to obtain the lowest possible detection limits with the best resolution while monitoring the SSV for any hydrogen, helium, oxygen, or argon as the main requirement. The HGDS is a redundant mass spectrometer used for real-time monitoring during Power Reactant Storage and Distribution (PRSD) load and ET load through launch or scrub. This system also performs SSV processing leak checks of the Tail Service Mast (TSM) umbilical quick disconnects (QD's), Ground Umbilical Carrier Plate (GUCP) QD's and supports auxiliary power unit (APU) system tests. From design to initial implementation and operations, the HGDS has evolved into a mature and reliable launch support system. This paper will discuss the operational challenges and lessons learned from facing design deficiencies, validation and maintenance efforts, life cycle issues, and evolving requirements

  7. Does vitamin C deficiency affect cognitive development and function?

    DEFF Research Database (Denmark)

    Hansen, Stine Normann; Tveden-Nyborg, Pernille; Lykkesfeldt, Jens

    2014-01-01

    Vitamin C is a pivotal antioxidant in the brain and has been reported to have numerous functions, including reactive oxygen species scavenging, neuromodulation, and involvement in angiogenesis. Absence of vitamin C in the brain has been shown to be detrimental to survival in newborn SVCT2(-/-) mice...... and perinatal deficiency have shown to reduce hippocampal volume and neuron number and cause decreased spatial cognition in guinea pigs, suggesting that maternal vitamin C deficiency could have severe consequences for the offspring. Furthermore, vitamin C deficiency has been proposed to play a role in age......-related cognitive decline and in stroke risk and severity. The present review discusses the available literature on effects of vitamin C deficiency on the developing and aging brain with particular focus on in vivo experimentation and clinical studies....

  8. What Is Combined Deficiency of Vitamin K-Dependent Clotting Factors?

    Science.gov (United States)

    ... Deficiency Factor V Deficiency Combined FV & FVIII Deficiencies Factor VII Deficiency Factor X Deficiency Factor XI Deficiency Factor ... Deficiency Factor V Deficiency Combined FV & FVIII Deficiencies Factor VII Deficiency Factor X Deficiency Factor XI Deficiency Factor ...

  9. Oxygen sensitive polymeric nanocapsules for optical dissolved oxygen sensors

    Science.gov (United States)

    Sun, Zhijuan; Cai, Chenxin; Guo, Fei; Ye, Changhuai; Luo, Yingwu; Ye, Shuming; Luo, Jianchao; Zhu, Fan; Jiang, Chunyue

    2018-04-01

    Immobilization of the oxygen-sensitive probes (OSPs) in the host matrix greatly impacts the performance and long-term usage of the optical dissolved oxygen (DO) sensors. In this work, fluorescent dyes, as the OSPs, were encapsulated with a crosslinked fluorinated polymer shell by interfacial confined reversible addition fragmentation chain transfer miniemulsion polymerization to fabricate oxygen sensitive polymeric nanocapsules (NCs). The location of fluorescent dyes and the fluorescent properties of the NCs were fully characterized by fourier transform infrared spectrometer, x-ray photoelectron spectrometer and fluorescent spectrum. Dye-encapsulated capacity can be precisely tuned from 0 to 1.3 wt% without self-quenching of the fluorescent dye. The crosslinked fluorinated polymer shell is not only extremely high gas permeability, but also prevents the fluorescent dyes from leakage in aqueous as well as in various organic solvents, such as ethanol, acetone and tetrahydrofuran (THF). An optical DO sensor based on the oxygen sensitive NCs was fabricated, showing high sensitivity, short response time, full reversibility, and long-term operational stability of online monitoring DO. The sensitivity of the optical DO sensor is 7.02 (the ratio of the response value in fully deoxygenated and saturated oxygenated water) in the range 0.96-14.16 mg l-1 and the response time is about 14.3 s. The sensor’s work curve was fit well using the modified Stern-Volmer equation by two-site model, and its response values are hardly affected by pH ranging from 2 to 12 and keep constant during continuous measurement for 3 months. It is believed that the oxygen sensitive polymeric NCs-based optical DO sensor could be particularly useful in long-term online DO monitoring in both aqueous and organic solvent systems.

  10. Alpha-1 Antitrypsin Deficiency

    Science.gov (United States)

    ... 2008 Physical Activity Guidelines for Americans," the Health Topics Physical Activity and Your Heart article, and the NHLBI's " ... and children talk about their experiences with clinical research. More Information Related Health Topics Cough How the Lungs Work Lung Transplant Oxygen ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... your body. Cells in tissues need a steady supply of oxygen to work well. Normally, hemoglobin in ... began in 1989 to protect the nation’s blood supply and improve transfusions, found that many people, especially ...

  12. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... anemia may cause the following complications: Depression Heart problems. If you do not have enough hemoglobin-carrying red blood cells, your heart has to work harder to move oxygen-rich blood through your ...

  13. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... A-Z Clinical Trials Publications and Resources Health Education and Awareness The Science Science Home Blood Disorders ... carrying red blood cells, your heart has to work harder to move oxygen-rich blood through your ...

  14. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... have less hemoglobin than normal. Hemoglobin is a protein inside red blood cells that carries oxygen from ... stored iron has been used. Ferritin is a protein that helps store iron in your body. Reticulocyte ...

  15. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... cannot make as many new red blood cells. The red blood cells it does make have less hemoglobin than normal. Hemoglobin is a protein inside red blood cells that carries oxygen from ...

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... grams per deciliter (g/dl) for men and less than 12 g/dl for women is diagnostic of anemia. In iron-deficiency anemia, ... blood levels of iron will be low, or less than 10 micromoles per liter (mmol/L) for both men and women. Normal levels are 10 to 30 mmol/L. ...

  17. Alpha1-antitrypsin deficiency

    DEFF Research Database (Denmark)

    Stolk, Jan; Seersholm, Niels; Kalsheker, Noor

    2006-01-01

    The Alpha One International Registry (AIR), a multinational research program focused on alpha1-antitrypsin (AAT) deficiency, was formed in response to a World Health Organization recommendation. Each of the nearly 20 participating countries maintains a national registry of patients with AAT defic...

  18. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... is blood loss during dialysis. People who have chronic kidney disease also often take other medicines—such as proton ... reduces iron absorption. Other treatments If you have chronic kidney disease and iron-deficiency anemia, your doctor may recommend ...

  19. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... A-Z Clinical Trials Publications and Resources Health Education and Awareness The Science Science Home Blood Disorders ... Small Business Innovation Research (SBIR) and Small Business Technology Transfer (STTR) ... We are interested in learning how having iron-deficiency anemia early in life ...

  20. Arginase-1 deficiency.

    Science.gov (United States)

    Sin, Yuan Yan; Baron, Garrett; Schulze, Andreas; Funk, Colin D

    2015-12-01

    Arginase-1 (ARG1) deficiency is a rare autosomal recessive disorder that affects the liver-based urea cycle, leading to impaired ureagenesis. This genetic disorder is caused by 40+ mutations found fairly uniformly spread throughout the ARG1 gene, resulting in partial or complete loss of enzyme function, which catalyzes the hydrolysis of arginine to ornithine and urea. ARG1-deficient patients exhibit hyperargininemia with spastic paraparesis, progressive neurological and intellectual impairment, persistent growth retardation, and infrequent episodes of hyperammonemia, a clinical pattern that differs strikingly from other urea cycle disorders. This review briefly highlights the current understanding of the etiology and pathophysiology of ARG1 deficiency derived from clinical case reports and therapeutic strategies stretching over several decades and reports on several exciting new developments regarding the pathophysiology of the disorder using ARG1 global and inducible knockout mouse models. Gene transfer studies in these mice are revealing potential therapeutic options that can be exploited in the future. However, caution is advised in extrapolating results since the lethal disease phenotype in mice is much more severe than in humans indicating that the mouse models may not precisely recapitulate human disease etiology. Finally, some of the functions and implications of ARG1 in non-urea cycle activities are considered. Lingering questions and future areas to be addressed relating to the clinical manifestations of ARG1 deficiency in liver and brain are also presented. Hopefully, this review will spark invigorated research efforts that lead to treatments with better clinical outcomes.

  1. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Science Science Home Blood Disorders and Blood Safety Sleep Science and Sleep Disorders Lung Diseases Heart and Vascular Diseases Precision ... prevention and treatment of heart, lung, blood, and sleep disorders, including iron-deficiency anemia. Learn about the ...

  2. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... infection. A history of gastrointestinal surgery, such as weight-loss surgery—especially gastric bypass—or gastrectomy. Certain rare ... prevention and treatment of heart, lung, blood, and sleep disorders, including iron-deficiency anemia. Learn about the ...

  3. Vitamin B12 deficiency

    Science.gov (United States)

    Vitamin B12 (B12; also known as cobalamin) is a B vitamin that has an important role in cellular metabolism, especially in DNA synthesis, methylation and mitochondrial metabolism. Clinical B12 deficiency with classic haematological and neurological manifestations is relatively uncommon. However, sub...

  4. Leukocyte adhesion deficiencies

    NARCIS (Netherlands)

    van de Vijver, Edith; van den Berg, Timo K.; Kuijpers, Taco W.

    2013-01-01

    During inflammation, leukocytes play a key role in maintaining tissue homeostasis through elimination of pathogens and removal of damaged tissue. Leukocytes migrate to the site of inflammation by crawling over and through the blood vessel wall, into the tissue. Leukocyte adhesion deficiencies (ie,

  5. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron supplements work best to treat iron-deficiency anemia in children who do not consume the daily recommended amount ... and Clinical Studies to hear experts, parents, and children talk about their experiences with clinical ... Anemia Arrhythmia Blood Donation Blood Tests Blood ...

  6. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Working at the NHLBI Contact and FAQs Accessible Search Form Search the NHLBI, use the drop down list to ... treatment of blood diseases, including iron-deficiency anemia. Search the NIH Research Portfolio Online Reporting Tools (RePORT) ...

  7. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... or even heart failure . Increased risk of infections Motor or cognitive development delays in children Pregnancy complications, ... Upper endoscopy to look for bleeding in the esophagus, stomach, and the first part of the ... blood, and sleep disorders, including iron-deficiency anemia. Learn about the current ...

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... how having iron-deficiency anemia early in life affects later behavior, thinking, and mood during adolescence. Treating anemia in premature or very small newborns . In collaboration with the Eunice Kennedy Shriver National Institute of Child Health and Human Development, we are investigating how ...

  9. Iron deficiency in children

    African Journals Online (AJOL)

    cell and excess iron is stored as ferritin to protect the cell from oxidative ... iron deficiency has negative effects during pregnancy and in the postpartum period, which affects maternal health ... use of undiluted cow's milk and a predominant cow's milk intake in .... on bone marrow smear or biopsy for the definitive diagnosis of.

  10. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Certain conditions or medicines can decrease your body’s ability to absorb iron and lead to iron-deficiency ... environment or water. Lead interferes with the body’s ability to make hemoglobin. Family history and genetics Von ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... supplements. Iron supplements can change how certain medicines work. Your doctor may suggest check-ups to make sure your ... To prevent complications from iron-deficiency anemia, your doctor may ... during certain stages of life when more iron is needed, such as childhood ...

  12. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... an MCV of less than 80 femtoliters (fL). Prevention strategies If you have certain risk factors , such as if you are following a ... unhealthy environments, or other factors that increase your risk of developing iron-deficiency ... to Screening and Prevention to review tests to screen for and strategies ...

  13. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Services’ National Institutes of Health (NIH)—the Nation’s biomedical research agency that makes important scientific discoveries to improve ... efforts for iron-deficiency anemia. Learn about exciting research areas that ... This could help develop new therapies for conditions that affect the balance of iron ...

  14. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... the Eunice Kennedy Shriver National Institute of Child Health and Human Development, we are investigating how best to treat premature newborns with low hemoglobin levels. We also are hoping to determine which iron supplements work best to treat iron-deficiency anemia in children ...

  15. MCAD deficiency in Denmark

    DEFF Research Database (Denmark)

    Andresen, Brage Storstein; Lund, Allan Meldgaard; Hougaard, David Michael

    2012-01-01

    Medium-chain acyl-CoA dehydrogenase deficiency (MCADD) is the most common defect of fatty acid oxidation. Many countries have introduced newborn screening for MCADD, because characteristic acylcarnitines can easily be identified in filter paper blood spot samples by tandem mass spectrometry (MS/M...

  16. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... NHLBI News NHLBI in the Press Research Features All Events Past Events Upcoming Events About NHLBI About NHLBI Home Mission and Strategic Vision ... deficient Donors: Recovery and Storage Quality. Learn more about ... trial . View all trials from ClinicalTrials.gov . Visit Children and Clinical ...

  17. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... A-Z Clinical Trials Publications and Resources Health Education and Awareness The Science Science Home Blood Disorders ... Small Business Innovation Research (SBIR) and Small Business Technology Transfer (STTR) programs. Our ... more information about Donor Iron Deficiency Study - Red Blood Cells ...

  18. Isolated sulfite oxidase deficiency.

    Science.gov (United States)

    Rupar, C A; Gillett, J; Gordon, B A; Ramsay, D A; Johnson, J L; Garrett, R M; Rajagopalan, K V; Jung, J H; Bacheyie, G S; Sellers, A R

    1996-12-01

    Isolated sulfite oxidase (SO) deficiency is an autosomal recessively inherited inborn error of sulfur metabolism. In this report of a ninth patient the clinical history, laboratory results, neuropathological findings and a mutation in the sulfite oxidase gene are described. The data from this patient and previously published patients with isolated sulfite oxidase deficiency and molybdenum cofactor deficiency are summarized to characterize this rare disorder. The patient presented neonatally with intractable seizures and did not progress developmentally beyond the neonatal stage. Dislocated lenses were apparent at 2 months. There was increased urine excretion of sulfite and S-sulfocysteine and a decreased concentration of plasma cystine. A lactic acidemia was present for 6 months. Liver sulfite oxidase activity was not detectable but xanthine dehydrogenase activity was normal. The boy died of respiratory failure at 32 months. Neuropathological findings of cortical necrosis and extensive cavitating leukoencephalopathy were reminiscent of those seen in severe perinatal asphyxia suggesting an etiology of energy deficiency. A point mutation that resulted in a truncated protein missing the molybdenum-binding site has been identified.

  19. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... do not have enough iron in your body. People with mild or moderate iron-deficiency anemia may ... as a TMRPSS6 gene mutation that causes a person’s body to make too much of a hormone ...

  20. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... anemia, including: Vegetarian or vegan eating patterns. Not eating enough iron-rich foods, such as meat and fish, may result in ... deficiency anemia, your doctor may recommend heart-healthy eating and choosing iron-rich foods, especially during certain stages of life when more ...

  1. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia early in life affects later behavior, thinking, and mood during adolescence. Treating anemia in premature or very small newborns . In collaboration with the Eunice Kennedy Shriver National Institute of Child Health and Human Development, we are investigating how best to treat ...

  2. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia, including: Vegetarian or vegan eating patterns. Not eating enough iron-rich foods, such as meat and fish, may result in you getting less than the recommended daily amount of iron. Frequent blood donation. Individuals who donate blood often may be ...

  3. Familial lipoprotein lipase deficiency

    Science.gov (United States)

    ... lack an enzyme called lipoprotein lipase. Without this enzyme, the body cannot break down fat from digested food. Fat particles called chylomicrons build up in the blood. Risk factors include a family history of lipoprotein lipase deficiency. The condition is usually ...

  4. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Activities Obesity, Nutrition, and Physical Activity Population and Epidemiology Studies Women’s Health All Science A-Z Grants ... health for people with iron-deficiency anemia. Recipient Epidemiology Donor Studies program findings help to protect blood ...

  5. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... and save lives. We are committed to advancing science and translating discoveries into clinical practice to promote the prevention and treatment of heart, lung, blood, and sleep disorders, including iron-deficiency anemia. Learn about the current and future NHLBI efforts to improve health through ...

  6. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... iron-deficiency anemia early in life affects later behavior, thinking, and mood during adolescence. Treating anemia in premature or very small newborns . In collaboration with the Eunice Kennedy Shriver National Institute of Child Health and Human Development, we are investigating how ...

  7. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... with the Eunice Kennedy Shriver National Institute of Child Health and Human Development, we are investigating how best to treat premature newborns with low hemoglobin levels. We also are hoping to determine which iron supplements work best to treat iron-deficiency anemia in children ...

  8. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... of the body. When your heart has to work harder, this can lead to several conditions: irregular heartbeats called arrhythmias , a heart murmur , an ... chronic conditions, iron-deficiency anemia can make their condition worse or result in treatments not working as well. Look for Diagnosis will discuss any ...

  9. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... normally stores but has used up. Increase your intake of vitamin C to help your body absorb iron. Avoid drinking black tea, which reduces iron absorption. Other treatments If you have chronic kidney disease and iron-deficiency anemia, your doctor may recommend ...

  10. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... deficiency anemia. We stimulate high-impact research. Our Trans-Omics for Precision Medicine (TOPMed) Program now includes ... Studies (REDS) program Blood Disorders and Blood Safety Trans-Omics for Precision Medicine (TOPMed) Program Non-NHLBI ...

  11. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... Medicine (TOPMed) Program Non-NHLBI resources Anemia (National Library of Medicine, MedlinePlus) Anemia in Chronic Kidney Disease ( ... Supplement Fact Sheet (NIH) Iron-Deficiency Anemia (National Library of Medicine, MedlinePlus) Building 31 31 Center Drive ...

  12. Iodine-deficiency disorders

    NARCIS (Netherlands)

    Zimmermann, M.B.; Jooste, P.L.; Pandav, C.S.

    2008-01-01

    billion individuals worldwide have insufficient iodine intake, with those in south Asia and sub-Saharan Africa particularly affected. Iodine deficiency has many adverse effects on growth and development. These effects are due to inadequate production of thyroid hormone and are termed

  13. Single Cell Oxygen Mapping (SCOM) by Scanning Electrochemical Microscopy Uncovers Heterogeneous Intracellular Oxygen Consumption

    OpenAIRE

    Santos, Carla Santana; Kowaltowski, Alicia J.; Bertotti, Mauro

    2017-01-01

    We developed a highly sensitive oxygen consumption scanning microscopy system using platinized platinum disc microelectrodes. The system is capable of reliably detecting single-cell respiration, responding to classical regulators of mitochondrial oxygen consumption activity as expected. Comparisons with commercial multi-cell oxygen detection systems show that the system has comparable errors (if not smaller), with the advantage of being able to monitor inter and intra-cell heterogeneity in ox...

  14. Effect of epidural blockade and oxygen therapy on changes in subcutaneous oxygen tension after abdominal surgery

    DEFF Research Database (Denmark)

    Rosenberg, J; Pedersen, U; Erichsen, C J

    1994-01-01

    The effect of oxygen therapy (37% by face mask) and epidural local anesthetic blockade (9 ml 0.5% bupivacaine at Th9-11 level) on wound oxygenation was evaluated in eight otherwise healthy patients undergoing elective colorectal resection. The patients were monitored continuously for subcutaneous...... without epidural blockade and 15 (10-20) min with blockade (P surgery....

  15. Iron deficiency and cognitive functions

    Directory of Open Access Journals (Sweden)

    Jáuregui-Lobera I

    2014-11-01

    Full Text Available Ignacio Jáuregui-Lobera Department of Nutrition and Bromatology, Pablo de Olavide University, Seville, Spain Abstract: Micronutrient deficiencies, especially those related to iodine and iron, are linked to different cognitive impairments, as well as to potential long-term behavioral changes. Among the cognitive impairments caused by iron deficiency, those referring to attention span, intelligence, and sensory perception functions are mainly cited, as well as those associated with emotions and behavior, often directly related to the presence of iron deficiency anemia. In addition, iron deficiency without anemia may cause cognitive disturbances. At present, the prevalence of iron deficiency and iron deficiency anemia is 2%–6% among European children. Given the importance of iron deficiency relative to proper cognitive development and the alterations that can persist through adulthood as a result of this deficiency, the objective of this study was to review the current state of knowledge about this health problem. The relevance of iron deficiency and iron deficiency anemia, the distinction between the cognitive consequences of iron deficiency and those affecting specifically cognitive development, and the debate about the utility of iron supplements are the most relevant and controversial topics. Despite there being methodological differences among studies, there is some evidence that iron supplementation improves cognitive functions. Nevertheless, this must be confirmed by means of adequate follow-up studies among different groups. Keywords: iron deficiency, anemia, cognitive functions, supplementation

  16. Normal macrophage function in copper deficient mice

    International Nuclear Information System (INIS)

    Lukasewycz, O.A.; Kolquist, K.L.; Prohaska, J.R.

    1986-01-01

    Copper deficiency (-Cu) was produced in C57 BL and C58 mice by feeding a low copper diet (modified AIN-76A) from birth. Mice given supplemental copper in the drinking water (+Cu) served as controls. Copper status was monitored by assay of ceruloplasmin (CP) activity. Macrophages (M0) were obtained from matched +Cu and -Cu male 7 week-old mice by peritoneal lavage 3 days after thioglycollate stimulation. M0 were assayed in terms of lipopolysaccharide-induced hexose monophosphate shunt activity by monitoring 14 CO 2 production from [1- 14 C]-glucose and by the determination of phagocytic index using fluorescein labelled latex bead ingestion. M0 from -Cu mice were equivalent to those of +Cu mice in both these parameters. However, superoxide dismutase and cytochrome oxidase activities were both significantly lower in -Cu M0, confirming a functional copper deficiency. Previous results from this laboratory have shown that -Cu mice have a decreased antibody response to sheep erythrocyte antigens and a diminished reactivity to B and T cell mitogens. These immunological insufficiencies appear to be proportional to the severity of copper depletion as determined by CP levels. Furthermore, -Cu lymphocytes exhibit depressed mixed lymphocyte reactivity consistent with alterations at the membrane surface. The present results suggest that M0/monocytes are less severely affected than lymphocytes in copper deficiency states

  17. Optoacoustic measurements of human placenta and umbilical blood oxygenation

    Science.gov (United States)

    Nanovskaya, T. N.; Petrov, I. Y.; Petrov, Y.; Patrikeeva, S. L.; Ahmed, M. S.; Hankins, G. D. V.; Prough, D. S.; Esenaliev, R. O.

    2016-03-01

    Adequate oxygenation is essential for normal embryogenesis and fetal growth. Perturbations in the intrauterine oxidative environment during pregnancy are associated with several pathophysiological disorders such as pregnancy loss, preeclampsia, and intrauterine growth restriction. We proposed to use optoacoustic technology for monitoring placental and fetal umbilical blood oxygenation. In this work, we studied optoacoustic monitoring of oxygenation in placenta and umbilical cord blood ex vivo using technique of placenta perfusion. We used a medical grade, nearinfrared, tunable, optoacoustic system developed and built for oxygenation monitoring in blood vessels and in tissues. First, we calibrated the system for cord blood oxygenation measurements by using a CO-Oximeter (gold standard). Then we performed validation in cord blood circulating through the catheters localized on the fetal side of an isolated placental lobule. Finally, the oxygenation measurements were performed in the perfused placental tissue. To increase or decrease blood oxygenation, we used infusion of a gas mixture of 95% O2 + 5% CO2 and 95% N2 + 5% CO2, respectively. In placental tissue, up to four cycles of changes in oxygenation were performed. The optoacoustically measured oxygenation in circulating cord blood and in placental lobule closely correlated with the actual oxygenation data measured by CO-Oximeter. We plan to further test the placental and cord blood oxygenation monitoring with optoacoustics in animal and clinical studies.

  18. Implantable oxygen microelectrode suitable for medium-term investigations of post-surgical tissue hypoxia and changes in tumor tissue oxygenation produced by radiotherapy

    International Nuclear Information System (INIS)

    Burke, T.R.; Johnson, R.J.; Krishnamsetty, C.B.; Sako, K.; Karakousis, C.; Wojtas, F.

    1980-01-01

    Teflon-covered platinum oxygen probes were used to monitor tissue oxygen levels in post-surgical cancer patients and those treated with radiotherapy. Progressive wound healing was usually accompanied by a decrease in tissue pO2. Radiotherapy produced a slight increase in pO2 while hyperthermia effected a significant increase in the oxygen level during 100% oxygen breathing

  19. Adult growth hormone deficiency

    Directory of Open Access Journals (Sweden)

    Vishal Gupta

    2011-01-01

    Full Text Available Adult growth hormone deficiency (AGHD is being recognized increasingly and has been thought to be associated with premature mortality. Pituitary tumors are the commonest cause for AGHD. Growth hormone deficiency (GHD has been associated with neuropsychiatric-cognitive, cardiovascular, neuromuscular, metabolic, and skeletal abnormalities. Most of these can be reversed with growth hormone therapy. The insulin tolerance test still remains the gold standard dynamic test to diagnose AGHD. Growth hormone is administered subcutaneously once a day, titrated to clinical symptoms, signs and IGF-1 (insulin like growth factor-1. It is generally well tolerated at the low-doses used in adults. Pegylated human growth hormone therapy is on the horizon, with a convenient once a week dosing.

  20. Epidemiology of SHOX deficiency.

    Science.gov (United States)

    Nicolosi, A; Caruso-Nicoletti, M

    2010-06-01

    Deletion of short stature homeobox-containing (SHOX) gene, in the pseudoautosomal region (PAR1) of X and Y chromosomes, is an important cause of short stature. Homozygous loss of SHOX results in the more severe Langer mesomelic dysplasia, while SHOX haploinsufficiency cause a wide spectrum of short stature phenotypes, including patients with Turner syndrome, Leri Weill dyschondrosteosis (LWD), and idiopathic short stature (ISS). In Turner syndrome, haploinsufficiency of SHOX gene, as well as short stature, are present in 100%; nevertheless, SHOX deficiency accounts for only two-thirds of Turner patients' short stature. In LWD the prevalence of SHOX gene anomalies varies from 56% to 100%. This wide range might be due to different factors such as selection criteria of patients, sample size, and method used for screening SHOX mutations. The real challenge is to establish the prevalence of SHOX deficiency in ISS children given that published studies have reported this association with a very broad frequency range varying from 1.5% to 15%. An important variable in these studies is represented by the method used for screening SHOX mutations and sometimes by differences in patient selection. Short stature is present by definition in 3 out of 100 subjects; if we consider a frequency of SHOX defects of 3% among ISS, we should expect a population prevalence of 1 in 1000. This prevalence would be higher than that of GH deficiency (1:3,500) and of Turner syndrome (1:2,500 females), suggesting that SHOX deficiency could be one of the most frequent monogenetic causes of short stature.

  1. Biotin and biotinidase deficiency

    OpenAIRE

    Zempleni, Janos; Hassan, Yousef I; Wijeratne, Subhashinee SK

    2008-01-01

    Biotin is a water-soluble vitamin that serves as an essential coenzyme for five carboxylases in mammals. Biotin-dependent carboxylases catalyze the fixation of bicarbonate in organic acids and play crucial roles in the metabolism of fatty acids, amino acids and glucose. Carboxylase activities decrease substantially in response to biotin deficiency. Biotin is also covalently attached to histones; biotinylated histones are enriched in repeat regions in the human genome and appear to play a role...

  2. Biogeochemical cycling of iron and phosphorus under low oxygen conditions

    OpenAIRE

    Lomnitz, Ulrike

    2017-01-01

    Benthic release of the key nutrients iron (Fe) and phosphorus (P) is enhanced from sediments that are impinged by oxygen-deficient bottom waters due to its diminished retention capacity for such redox sensitive elements. Suboxic to anoxic and sometimes even euxinic conditions are recently found in open ocean oxygen minimum zones (OMZs, e.g. Eastern Boundary Upwelling Systems) and marginal seas (e.g. the Black Sea and the Baltic Sea). Recent studies showed that OMZs expanded in the last decade...

  3. Iron-Deficiency Anemia

    Medline Plus

    Full Text Available ... have less hemoglobin than normal. Hemoglobin is a protein inside red blood cells that carries oxygen from the lungs to tissues ... stored iron has been used. Ferritin is a protein that helps store iron in your ... very young red blood cells. Peripheral smear to see if your red blood ...

  4. Optimal oxygen saturation in premature infants

    Directory of Open Access Journals (Sweden)

    Meayoung Chang

    2011-09-01

    Full Text Available There is a delicate balance between too little and too much supplemental oxygen exposure in premature infants. Since underuse and overuse of supplemental oxygen can harm premature infants, oxygen saturation levels must be monitored and kept at less than 95% to prevent reactive oxygen species-related diseases, such as retinopathy of prematurity and bronchopulmonary dysplasia. At the same time, desaturation below 80 to 85% must be avoided to prevent adverse consequences, such as cerebral palsy. It is still unclear what range of oxygen saturation is appropriate for premature infants; however, until the results of further studies are available, a reasonable target for pulse oxygen saturation (SpO2 is 90 to 93% with an intermittent review of the correlation between SpO2 and the partial pressure of arterial oxygen tension (PaO2. Because optimal oxygenation depends on individuals at the bedside making ongoing adjustments, each unit must define an optimal target range and set alarm limits according to their own equipment or conditions. All staff must be aware of these values and adjust the concentration of supplemental oxygen frequently.

  5. Prevalence of glucose-6-phosphate dehydrogenase (G6PD) deficiency among malaria patients in Upper Myanmar.

    Science.gov (United States)

    Lee, Jinyoung; Kim, Tae Im; Kang, Jung-Mi; Jun, Hojong; Lê, Hương Giang; Thái, Thị Lam; Sohn, Woon-Mok; Myint, Moe Kyaw; Lin, Khin; Kim, Tong-Soo; Na, Byoung-Kuk

    2018-03-16

    Glucose-6-phosphate dehydrogenase (G6PD; EC 1.1.1.49) deficiency is one of the most common X-linked recessive hereditary disorders in the world. Primaquine (PQ) has been used for radical cure of P. vivax to prevent relapse. Recently, it is also used to reduce P. falciparum gametocyte carriage to block transmission. However, PQ metabolites oxidize hemoglobin and generate excessive reactive oxygen species which can trigger acute hemolytic anemia in malaria patients with inherited G6PD deficiency. A total of 252 blood samples collected from malaria patients in Myanmar were used in this study. G6PD variant was analysed by a multiplex allele specific PCR kit, DiaPlexC™ G6PD Genotyping Kit [Asian type]. The accuracy of the multiplex allele specific PCR was confirmed by sequencing analysis. Prevalence and distribution of G6PD variants in 252 malaria patients in Myanmar were analysed. Six different types of G6PD allelic variants were identified in 50 (7 females and 43 males) malaria patients. The predominant variant was Mahidol (68%, 34/50), of which 91.2% (31/34) and 8.8% (3/34) were males and females, respectively. Other G6PD variants including Kaiping (18%, 9/50), Viangchan (6%, 3/50), Mediterranean (4%, 2/50), Union (2%, 1/50) and Canton (2%, 1/50) were also observed. Results of this study suggest that more concern for proper and safe use of PQ as a radical cure of malaria in Myanmar is needed by combining G6PD deficiency test before PQ prescription. Establishment of a follow-up system to monitor potential PQ toxicity in malaria patients who are given PQ is also required.

  6. Internal-reference solid-electrolyte oxygen sensor

    International Nuclear Information System (INIS)

    Haaland, D.M.

    1977-01-01

    A new solid-electrolyte oxygen sensor has been developed that eliminates the conventional oxygen reference in previous solid-electrolyte oxygen sensor designs and is, therefore, ideally suited as an insertion device for remote oxygen monitoring applications. It is constructed with two cells of stabilized zirconia sealed into a small unit using a new high-temperature platinum-zirconia seal. One electrochemical cell monitors the ratio of oxygen partial pressures inside and outside the sensor while the other solid-electrolyte cell is used for quantitative electrochemical pumping of oxygen. The internal oxygen reference is generated by initially pumping all oxygen out of the known internal volume of the sensor and then quantitatively pumping oxygen back in until oxygen partial pressures are equal inside and out. This information is used with the ideal gas law to calculate oxygen partial pressures. Tests were conducted from 400 to 1000 0 C in mixtures of oxygen and nitrogen spanning approximately 0.2 to 21 percent oxygen concentration range. Sensors with sputtered platinum and porous platinum paste electrodes were compared

  7. Pseudoachondroplasia with immune deficiency

    International Nuclear Information System (INIS)

    Kultursay, N.; Taneli, B.; Cavusoglu, A.

    1988-01-01

    A 5-year old boy was admitted to the hospital with failure to thrive since he was 2 years old, with weakness in his legs and a waddling gait. He has normal mental development. His parents are normal phenotypically and are unrelated. In analysing his pedigree only a grandfather is described to have waddling gait. He has a normal craniofacial appearance but a disproportionate body with normal trunk and short extremities with height below the 3rd percentile. The diagnosis of pseudoachondroplasia was made on clinical, radiological and laboratory findings. He also had immune deficiency characterised by low T-lymphocyte populations and a low level of serum immunoglobulin A. (orig.)

  8. Primary Carnitine Deficiency

    DEFF Research Database (Denmark)

    Rasmussen, Jan; Hougaard, David M; Sandhu, Noreen

    2017-01-01

    Primary carnitine deficiency (PCD) causes low levels of carnitine in patients potentially leading to metabolic and cardiac symptoms. Newborn screening for PCD is now routine in many countries by measuring carnitine levels in infants. In this study we report Apgar scores, length and weight...... scores, length and weight compared to controls. Newborns with PCD and newborns born to mothers with PCD had significantly lower levels of free carnitine (fC0) than controls. Screening algorithms focusing only on fC0 had a high rate of detection of newborns with PCD. Sample collection 4-9 days after birth...

  9. Iron, Anemia, and Iron Deficiency Anemia among Young Children in the United States

    OpenAIRE

    Gupta, Priya M.; Perrine, Cria G.; Mei, Zuguo; Scanlon, Kelley S.

    2016-01-01

    Iron deficiency and anemia are associated with impaired neurocognitive development and immune function in young children. Total body iron, calculated from serum ferritin and soluble transferrin receptor concentrations, and hemoglobin allow for monitoring of the iron and anemia status of children in the United States. The purpose of this analysis is to describe the prevalence of iron deficiency (ID), anemia, and iron deficiency anemia (IDA) among children 1–5 years using data from the 2007–201...

  10. Glucose-6-phosphatase deficiency

    Directory of Open Access Journals (Sweden)

    Labrune Philippe

    2011-05-01

    Full Text Available Abstract Glucose-6-phosphatase deficiency (G6P deficiency, or glycogen storage disease type I (GSDI, is a group of inherited metabolic diseases, including types Ia and Ib, characterized by poor tolerance to fasting, growth retardation and hepatomegaly resulting from accumulation of glycogen and fat in the liver. Prevalence is unknown and annual incidence is around 1/100,000 births. GSDIa is the more frequent type, representing about 80% of GSDI patients. The disease commonly manifests, between the ages of 3 to 4 months by symptoms of hypoglycemia (tremors, seizures, cyanosis, apnea. Patients have poor tolerance to fasting, marked hepatomegaly, growth retardation (small stature and delayed puberty, generally improved by an appropriate diet, osteopenia and sometimes osteoporosis, full-cheeked round face, enlarged kydneys and platelet dysfunctions leading to frequent epistaxis. In addition, in GSDIb, neutropenia and neutrophil dysfunction are responsible for tendency towards infections, relapsing aphtous gingivostomatitis, and inflammatory bowel disease. Late complications are hepatic (adenomas with rare but possible transformation into hepatocarcinoma and renal (glomerular hyperfiltration leading to proteinuria and sometimes to renal insufficiency. GSDI is caused by a dysfunction in the G6P system, a key step in the regulation of glycemia. The deficit concerns the catalytic subunit G6P-alpha (type Ia which is restricted to expression in the liver, kidney and intestine, or the ubiquitously expressed G6P transporter (type Ib. Mutations in the genes G6PC (17q21 and SLC37A4 (11q23 respectively cause GSDIa and Ib. Many mutations have been identified in both genes,. Transmission is autosomal recessive. Diagnosis is based on clinical presentation, on abnormal basal values and absence of hyperglycemic response to glucagon. It can be confirmed by demonstrating a deficient activity of a G6P system component in a liver biopsy. To date, the diagnosis is most

  11. Biogeochemistry: Oxygen burrowed away

    NARCIS (Netherlands)

    Meysman, F.J.R.

    2014-01-01

    Multicellular animals probably evolved at the seafloor after a rise in oceanic oxygen levels. Biogeochemical model simulations suggest that as these animals started to rework the seafloor, they triggered a negative feedback that reduced global oxygen.

  12. Oxygen transport membrane

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a novel composite oxygen transport membrane as well as its preparation and uses thereof.......The present invention relates to a novel composite oxygen transport membrane as well as its preparation and uses thereof....

  13. Proterozoic atmospheric oxygen

    DEFF Research Database (Denmark)

    Canfield, Donald Eugene

    2014-01-01

    This article is concerned with the evolution of atmospheric oxygen concentrations through the Proterozoic Eon. In particular, this article will seek to place the history of atmospheric oxygenation through the Proterozoic Eon in the context of the evolving physical environment including the history...... of continental growth and volcanic outgassing, as well as biogeochemical processing of elements within the oceans. The author will seek to explore constraints on the history of oxygenation and understand which processes have regulated oxygen through this eon....

  14. Oxygen evolution reaction catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Haber, Joel A.; Jin, Jian; Xiang, Chengxiang; Gregoire, John M.; Jones, Ryan J.; Guevarra, Dan W.; Shinde, Aniketa A.

    2016-09-06

    An Oxygen Evolution Reaction (OER) catalyst includes a metal oxide that includes oxygen, cerium, and one or more second metals. In some instances, the cerium is 10 to 80 molar % of the metals in the metal oxide and/or the catalyst includes two or more second metals. The OER catalyst can be included in or on an electrode. The electrode can be arranged in an oxygen evolution system such that the Oxygen Evolution Reaction occurs at the electrode.

  15. GLUT1 deficiency with delayed myelination responding to ketogenic diet.

    NARCIS (Netherlands)

    Klepper, J.; Engelbrecht, V.; Scheffer, H.; Knaap, M.S. van der; Fiedler, A.

    2007-01-01

    Monitoring effects of a ketogenic diet in GLUT1 deficiency syndrome without seizures is difficult. Neuroimaging is considered uninformative. We report the case of a boy with neurodevelopmental delay, severe ataxia, an E54X-mutation in the SLC2A1 gene (previously GLUT1), and neuroimaging

  16. GLUT1 deficiency with delayed myelination responding to ketogenic diet

    NARCIS (Netherlands)

    Klepper, Jörg; Engelbrecht, Volkher; Scheffer, Hans; van der Knaap, Marjo S.; Fiedler, Andreas

    2007-01-01

    Monitoring effects of a ketogenic diet in GLUT1 deficiency syndrome without seizures is difficult. Neuroimaging is considered uninformative. We report the case of a boy with neurodevelopmental delay, severe ataxia, an E54X-mutation in the SLC2A1 gene (previously GLUT1), and neuroimaging

  17. [Domiciliary oxygen therapy].

    Science.gov (United States)

    Abdel Kafi, S

    2010-09-01

    In Belgium, oxygen therapy is becoming more and more accessible. When oxygen is needed for short periods or for special indications as palliative care, an agreement between mutual insurance companies and pharmacists allows the practitioner the home installation of gazeous oxygen cylinder or of oxygen concentrator. When long term oxygen therapy (LTOT) is indicated for patients with respiratory insufficiency, the pneumologist must first ask the INAMI the authorization to install one of the following modalities: oxygen concentrator with or without demand oxygen delivery cylinder and liquid oxygen. The goal of LTOT is to increase survival and quality of life. The principal and well accepted indication for LTOT is severe hypoxemia. The beneficial effects of oxygen therapy limited at night or on exertion are controversial. In order to increase patient's autonomy, oxygen can be prescribed for ambulation, respecting prescription's rules. At each step of oxygen therapy implementing (indication, choice of the device and follow-up) the patient under oxygen may benefit from a joint approach between the general practitioner and the chest specialist.

  18. Aircraft Oxygen Generation

    Science.gov (United States)

    2012-02-01

    An Oxygen Enriched Air System for the AV-8A Harrier (NADC-81198-60).” 70 Horch , T., et. al. “The F-16 Onboard Oxygen Generating System: Performance...Only and Safety Privileged). Horch , T., Miller, R., Bomar, J., Tedor, J., Holden, R., Ikels, K., & Lozano, P. (1983). The F-16 Onboard Oxygen

  19. [Vitamin deficiencies in breastfed children due to maternal dietary deficiency

    NARCIS (Netherlands)

    Kollee, L.A.A.

    2006-01-01

    Dietary deficiencies of vitamin B12 and vitamin D during pregnancy and lactation may result in health problems in exclusively breastfed infants. Vitamin-B12 deficiency in these infants results in irritability, anorexia and failure to thrive during the first 4-8 months of life. Severe and permanent

  20. [Pregnancy toxemia. Oxygen input/extraction in preeclampsia-eclampsia].

    Science.gov (United States)

    Rodríguez-Badillo, R F; Noriega-R, T; Audifred-Salomón, J R; García-Lara, E

    1996-07-01

    We tried to determine if the toxemia of pregnancy has during its clinical evolution a dependent DO2/VO2 relationship and determine its critical DO2 and finally define if this has a prognostic value. There were included patients with diagnosis of preeclampsia/eclampsia that were enter at the Intensive Care Unit for treatment and monitoring. It was placed a catheter in the pulmonary artery and it was determine the cardiac output and by means of standard formulas the DO2, VO2 and EO2 were calculated. The critical delivery of oxygen was stablished in agree at the Gutiérrez's method. At the same time it was monitorised the base excess which was gotten from arterial and venous blood gases. 36 patients (29 with preclampsia and 7 with eclampsia) were included, with a mean age of 26.3 years old. The mean gestational age was 36.1 weeks. The critical delivery for preeclamptic patients was stablished in 924 mL/min and at the eclamptic patients in 830 mL/min: both values had prognostic correlation with survival and nonsurvival patients (p 30%. The toxemia of pregnancy had a behaviour like state accompaniment of a dependent DO2/VO2 relationship causing an important oxygen deficient that was improved was improved in the survival patients that reach values over the critical delivery. These facts suggesting the presence of a metabolic blockade in variable degree that can improve or increase agree a therapeutic manipulations in the critic DO2.