WorldWideScience

Sample records for oxoid aura image

  1. Magnetic resonance image abnormality in migraine with aura

    Energy Technology Data Exchange (ETDEWEB)

    Ziegler, D.K.; Batnitzky, S.; Barter, R.; McMillan, J.H. (Kansas Univ., Kansas City, KS (United States). Medical Center)

    1991-07-01

    Cerebral magnetic resonance imaging (MRI) was performed on 18 patients with migraine characterized by aura consisting of both visual symtoms and parasthesias. 15 headache-free individuals of the same age range were used as controls. Records were radomized and read in blind fashion by two neuroradiologists. Small subcortical white matter lesions were seen in three migraine cases and two controls. In one migraine case cortical infarctions were seen. In two controls, small areas of increased density similar to those in migraine were seen. No consistent correlation of migraine or its duration with cerebral atrophy was found. It is concluded that identification of both these MRI findings (small subcortical white lesions and cerebral atrophy) as significantly associated with migraine is doubtful. 21 refs., 2 figs.

  2. Magnetic resonance image abnormality in migraine with aura

    International Nuclear Information System (INIS)

    Ziegler, D.K.; Batnitzky, S.; Barter, R.; McMillan, J.H.

    1991-01-01

    Cerebral magnetic resonance imaging (MRI) was performed on 18 patients with migraine characterized by aura consisting of both visual symtoms and parasthesias. 15 headache-free individuals of the same age range were used as controls. Records were radomized and read in blind fashion by two neuroradiologists. Small subcortical white matter lesions were seen in three migraine cases and two controls. In one migraine case cortical infarctions were seen. In two controls, small areas of increased density similar to those in migraine were seen. No consistent correlation of migraine or its duration with cerebral atrophy was found. It is concluded that identification of both these MRI findings (small subcortical white lesions and cerebral atrophy) as significantly associated with migraine is doubtful. 21 refs., 2 figs

  3. Heterogenous migraine aura symptoms correlate with visual cortex functional magnetic resonance imaging responses

    DEFF Research Database (Denmark)

    Arngrim, Nanna; Hougaard, Anders; Ahmadi, Khazar

    2017-01-01

    Objective: Migraine aura is sparsely studied due to the highly challenging task of capturing patients during aura. Cortical spreading depression (CSD) is likely the underlying phenomenon of aura. The possible correlation between the multifaceted phenomenology of aura symptoms and the effects of CSD...... on the brain has not been ascertained. Methods: Five migraine patients were studied during various forms of aura symptoms induced by hypoxia, sham hypoxia, or physical exercise with concurrent photostimulation. The blood oxygenation level–dependent (BOLD) functional magnetic resonance imaging (fMRI) signal...... response to visual stimulation was measured in retinotopic mapping–defined visual cortex areas V1 to V4. Results: We found reduced BOLD response in patients reporting scotoma and increased response in patients who only experienced positive symptoms. Furthermore, patients with bilateral visual symptoms had...

  4. Investigations of functional and structural changes in migraine with aura by magnetic resonance imaging

    DEFF Research Database (Denmark)

    Hougaard, Anders

    2015-01-01

    technology to study these features of migraine with aura (MA) is functional magnetic resonance imaging (fMRI), which has the potential not only to detect, but also to localize hypersensitive cortex. The main objective of this thesis was to investigate the cortical responsivity of patients with MA during.......e. ≥= 90% of auras occurring in the same visual hemifield (study II). To circumvent bias relating to differences between right and left hemispheres (e.g. caused by physiological left/right bias, asymmetry of the visual stimulation or magnetic field inhomogeneity of the scanner), we included an equal number...

  5. Migraine aura

    DEFF Research Database (Denmark)

    Charles, Andrew; Hansen, Jakob Møller

    2015-01-01

    classification of migraine aura is becoming both broader and more detailed. Traditionally viewed as a primary event that triggers a migraine attack, studies regarding the timing of aura relative to other symptoms of migraine indicate that it may not in fact play a primary role in initiating an attack. Careful....... SUMMARY: There has been significant evolution of concepts regarding the causes of migraine aura, how it is best defined, and how it fits into the picture of the migraine disorder as a whole. Regardless of its exact role in the genesis of migraine, an increased understanding of aura has the potential...

  6. Magnetic resonance imaging in children presenting migraine with aura: Association of hypoperfusion detected by arterial spin labelling and vasospasm on MR angiography findings.

    Science.gov (United States)

    Cadiot, Domitille; Longuet, Romain; Bruneau, Bertrand; Treguier, Catherine; Carsin-Vu, Aline; Corouge, Isabelle; Gomes, Constantin; Proisy, Maïa

    2018-04-01

    Objective A child presenting with a first attack of migraine with aura usually undergoes magnetic resonance imaging (MRI) to rule out stroke. The purpose of this study was to report vascular and brain perfusion findings in children suffering from migraine with aura on time-of-flight MR angiography (TOF-MRA) and MR perfusion imaging using arterial spin labelling (ASL). Methods We retrospectively included all children who had undergone an emergency MRI examination with ASL and TOF-MRA sequences for acute neurological deficit and were given a final diagnosis of migraine with aura. The ASL perfusion maps and TOF-MRA images were independently assessed by reviewers blinded to clinical data. A mean cerebral blood flow (CBF) value was obtained for each cerebral lobe after automatic data post-processing. Results Seventeen children were finally included. Hypoperfusion was identified in one or more cerebral lobes on ASL perfusion maps by visual assessment in 16/17 (94%) children. Vasospasm was noted within the intracranial vasculature on the TOF-MRA images in 12/17 (71%) children. All (100%) of the abnormal TOF-MRA images were associated with homolateral hypoperfusion. Mean CBF values were significantly lower ( P < 0.05) in visually hypoperfused lobes than in normally perfused lobes. Conclusion ASL and TOF-MRA are two totally non-invasive, easy-to-use MRI sequences for children in emergency settings. Hypoperfusion associated with homolateral vasospasm may suggest a diagnosis of migraine with aura.

  7. The image of Thought. The aura of the figure between philosophy and anthropology

    Directory of Open Access Journals (Sweden)

    Stefano Lilliu

    2012-04-01

    Full Text Available Il saggio svolge un’indagine sull’emergere delle prime forme di figurazione e sul legame che esse intrattengono con la nascita della concettualità umana. Tramite la storia della figura si presenta un grande bivio della storia delle civiltà, la biforcazione essenziale causata dai due grandi modi di mettere all’opera la figura: da una parte l’operazione occidentale del senso, enucleata dalle analisi di Carlo Sini, dall’altra l’espressione figurativa delle trasformazioni naturali colta dall’ideogramma orientale, che produce un alternativo universo di senso, illustrata brillantemente da Fenollosa e Jullien. Attraverso l’evocazione dell’aura dei due diversi universi figurativi si tenta di delineare un percorso genealogico che ricostruisca un’unica immagine di pensiero.

  8. Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia

    International Nuclear Information System (INIS)

    Weinstein, M.P.; Mirrett, S.; Reller, L.B.

    1988-01-01

    The Oxoid Signal blood culture system is a newly described, innovative method for visually detecting growth of microorganisms. We did 5,999 paired comparisons of equal volumes (10 ml) of blood in the Oxoid Signal and BACTEC radiometric blood culture systems at two university hospitals that use identical methods of obtaining and processing specimens. Overall, more microorganisms were detected in the BACTEC system (P less than 0.001), in particular, streptococci (P less than 0.01), fungi (P less than 0.001), and nonfermentative gram-negative rods, especially Acinetobacter species (P less than 0.001). Trends favoring the BACTEC system for detection of Pseudomonas aeruginosa, Haemophilus species, and Neisseria species were noted. There were no differences in the yield of staphylococci, members of the family Enterobacteriaceae, and anaerobic bacteria. When both systems detected sepsis, the BACTEC did so earlier (P less than 0.001). This advantage was most notable at 24 h (70% of BACTEC positives detected versus 48% of Oxoid positives). The proportion of positives detected after 48 h, however, was similar (BACTEC, 84%; Oxoid, 78%). Revisions in the Oxoid Signal system itself or in the processing of Oxoid bottles appear to be necessary to improve its performance in detecting certain microorganism groups, especially fungi

  9. Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system

    International Nuclear Information System (INIS)

    Weinstein, M.P.; Mirrett, S.; Reimer, L.G.; Reller, L.B.

    1989-01-01

    In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia. To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive cultures relative to the BACTEC radiometric system, we agitated all Oxoid bottles during the first 24 to 48 h of incubation and performed aerobic and anaerobic subcultures of all Oxoid bottles negative after 7 days of incubation. These modifications improved the overall performance of the Oxoid system, particularly with regard to the yield of streptococci, members of the family Enterobacteriaceae, and Haemophilus, Neisseria, and Acinetobacter spp. The speed of detecting positive cultures also was improved, especially within the first 24 h of incubation. However, the BACTEC system still detected more positive cultures (P less than 0.005), especially of obligate aerobes such as Pseudomonas aeruginosa (P less than 0.05) and yeasts (P less than 0.005). The BACTEC system also detected positive cultures earlier than the Oxoid system (e.g., at 24 h of incubation, 70.5% of BACTEC positive cultures detected versus 62.1% of Oxoid positive cultures detected). Further modifications of the Oxoid system which might include a revised medium, additional processing modifications, altered headspace atmosphere, or a complementary second broth medium should be considered, since the system is attractive in concept and is easy to use in the clinical laboratory

  10. Improved description of the migraine aura by a diagnostic aura diary

    DEFF Research Database (Denmark)

    Russell, M B; Iversen, Helle Klingenberg; Olesen, J

    1994-01-01

    We present a diagnostic aura diary for prospective recordings of migraine with aura. Three questionnaires are supplemented with sheets for drawings and plottings of visual and sensory auras. Twenty patients recorded 54 attacks of migraine with aura and 2 attacks of migraine aura without headache...... head pain, headache and aura symptoms were contralateral in 90% and ipsilateral in 10%....

  11. HR Mission | AURA Human Resources

    Science.gov (United States)

    AURA Policies Conflict of Interest Employee Recognition Forms Library Handbook Integrity Line Manager responsiveness; Striving for a multicultural, innovative and diverse team that operates with respect and

  12. Sensory migraine aura is not associated with structural grey matter abnormalities

    DEFF Research Database (Denmark)

    Hougaard, Anders; Amin, Faisal Mohammad; Arngrim, Nanna

    2016-01-01

    Migraine with aura (MA) is characterized by cortical dysfunction. Frequent aura attacks may alter cerebral cortical structure in patients, or structural grey matter abnormalities may predispose MA patients to aura attacks. In the present study we aimed to investigate cerebral grey matter structure...... sensory aura regularly. We analysed high-resolution structural MR images using two complimentary approaches and compared patients with and without sensory aura. Patients were also compared to controls. We found no differences of grey matter density or cortical thickness between patients with and without...... sensory aura and no differences for the cortical visual areas between patients and controls. The somatosensory cortex was thinner in patients (1.92 mm vs. 1.96 mm, P = 0.043) and the anterior cingulate cortex of patients had a decreased grey matter density (P = 0.039) compared to controls...

  13. Comparison of Rosco Neo-Sensitabs with Oxoid paper disks in EUCAST disk diffusion antimicrobial susceptibility testing on Mueller-Hinton agar

    DEFF Research Database (Denmark)

    Justesen, U S; Acar, Ziyap; Olsson, K

    2013-01-01

    This study compared Neo-Sensitabs with Oxoid paper disks using the European Committee on Antimicrobial Susceptibility Testing (EUCAST) disk diffusion antimicrobial susceptibility test on Mueller-Hinton agar. The EUCAST-recommended quality control strains (Escherichia coli ATCC 25922, Pseudomonas...... paper disks for EUCAST disk diffusion antimicrobial susceptibility testing on Mueller-Hinton agar....

  14. Neurophysiology of visual aura in migraine

    International Nuclear Information System (INIS)

    Shibata, Koichi

    2007-01-01

    Visual processing in migraine has been targeted because the visual symptoms that are commonly associated with attack, either in the form of aura or other more subtle symptoms, indicate that the visual pathways are involved in migrainous pathophysiology. The visual aura of the migraine attack has been explained by the cortical spreading depression (CSD) of Leao, neuroelectric event beginning in the occipital cortex and propagating into contiguous brain region. Clinical observations suggest that hyperexcitability occurs not only during the attack, typically in the form of photophobia, but also between attacks. Numerous human neuroimaging, neurophysiological and psychophysical studies have identified differences in cortical visual processing in migraine. The possibility of imaging the typical visual aura with BOLD functional MRI has revealed multiple neurovascular events in the occipital cortex within a single attack that closely resemble CSD. As transient synchronized neuronal excitation precedes CSD, changes in cortical excitability underlie the migraine attack. Independent evidence for altered neuronal excitability in migraineurs between attacks emerges from visual evoked potentials (VEPs) and transcranial magnetic stimulation (TMS), recordings of cortical potentials and psychophysics. Recently, both TMS and psychophysical studies measuring visual performance in migraineurs have used measures which presumably measure primary visual (V1) and visual association cortex. Our VEP and blink reflex study showed that migraine patients exhibiting allodynia might show central sensitization of braistem trigeminal neuron and had contrast modulation dysfunction during the cortical visual processing of V1 and visual association cortex in-between attacks. In pathophysiology of migraine, these neurophysiological and psychophysical studies indicate that abnormal visual and trigeminal hyperexcitability might persist between migraine attacks. The influence of migraine on cortical

  15. An evaluation of the Oxoid Biochemical Identification System Campy rapid screening test for Campylobacteraceae and Helicobacter spp.

    Science.gov (United States)

    Hoosain, N; Lastovica, A J

    2009-06-01

    To evaluate the Oxoid Biochemical Identification System (OBIS) Campy test (ID0800M) against Campylobacter; Arcobacter; and other micro-organisms, with similar colonial morphology, for the detection of l-alanine aminopeptidase (l-ALA). The KOH and l-ALA (OBIS and Fluka) tests were carried out on every isolate. The procedures were followed as indicated in the OBIS and Fluka kit instructions. A total of 146 strains of 19 species of Campylobacter, seven strains of Arcobacter butzleri, four Arcobacter butzleri-like strains, 42 strains of 10 species of Helicobacter, 96 Gram-negative and 49 Gram-positive clinical isolates were tested. As expected, Campylobacter and Arcobacter strains were negative, while other Gram-negative bacteria were positive for the l-ALA test. An unexpected finding was that Helicobacter strains, although Gram-negative, were all negative for the l-ALA tests suggesting the absence of l-ALA within this genus. This is a novel finding. The absence of l-ALA was confirmed upon comparison with the available full genomic sequences of Helicobacter on the NCBI database. The OBIS Campy (ID0800M) test kit proved to be rapid and accurate for the presumptive characterization of Campylobacter and Arcobacter. A novel finding was that Helicobacter species also did not have the l-ALA enzyme. The OBIS kit will be useful in diagnostic laboratories for the presumptive diagnosis of Campylobacter, Arcobacter and Helicobacter strains.

  16. Aura, Self, and Aesthetic Experience

    OpenAIRE

    Marshall Battani

    2011-01-01

    Aesthetic experiences are generated in encounters with cultural objects and such experiences are marked by the free play of cognitive and numinous experience unstructured by concepts. Kant’s famous three types of pleasure, made infamous in social theory by Pierre Bourdieu, are examined in relation to the critical theoretical concept of aura, the social psychology of “flow,” and cognitive explanations of perception to explain experience in aesthetic fields. Theories of aesthetic experience de...

  17. Reduced efficacy of sumatriptan in migraine with aura vs without aura

    DEFF Research Database (Denmark)

    Hansen, Jakob Møller; Goadsby, Peter J; Charles, Andrew

    2015-01-01

    treated attacks with aura (24%) (p freedom 2 hours postdose for attacks without aura was 1.33 (95% confidence interval: 1.16-1.54). The number needed to treat for 2 hours of pain freedom was 4.4 for attacks without aura and 6.2 for attacks with aura. For the clinical...... trial of DHE, the 2-hour pain-free rates did not differ between patients treating attacks without aura (29.4%) compared with those who treated attacks with aura (27.2%; p = 0.65). The relative risk for pain freedom 2 hours postdose for attacks without aura vs with aura was 1.08 (95% confidence interval...

  18. Aura, Self, and Aesthetic Experience

    Directory of Open Access Journals (Sweden)

    Marshall Battani

    2011-01-01

    Full Text Available Aesthetic experiences are generated in encounters with cultural objects and such experiences are marked by the free play of cognitive and numinous experience unstructured by concepts. Kant’s famous three types of pleasure, made infamous in social theory by Pierre Bourdieu, are examined in relation to the critical theoretical concept of aura, the social psychology of “flow,” and cognitive explanations of perception to explain experience in aesthetic fields. Theories of aesthetic experience developed at the crossroad of critical social thought and cognitive science hold promise for a social analysis able to avoid the usual sociological pitfalls of either ignoring aesthetics or reducing it to structurally determined differences of taste.

  19. Cluster-like headache aura status

    NARCIS (Netherlands)

    Langedijk, M; van der Naalt, J; Luijckx, GJ; De Keyser, J

    We describe a patient with successive attacks (40 to 90 minutes) of cluster-like headache associated with aphasia, and contralateral hemihypesthesia and hemiplegia. The condition can best be described as cluster-like headache aura status.

  20. Migraine with aura is associated with an incomplete circle of willis: results of a prospective observational study.

    Directory of Open Access Journals (Sweden)

    Brett Cucchiara

    Full Text Available To compare the prevalence of an incomplete circle of Willis in patients with migraine with aura, migraine without aura, and control subjects, and correlate circle of Willis variations with alterations in cerebral perfusion.Migraine with aura, migraine without aura, and control subjects were prospectively enrolled in a 1∶1∶1 ratio. Magnetic resonance angiography was performed to examine circle of Willis anatomy and arterial spin labeled perfusion magnetic resonance imaging to measure cerebral blood flow. A standardized template rating system was used to categorize circle of Willis variants. The primary pre-specified outcome measure was the frequency of an incomplete circle of Willis. The association between circle of Willis variations and cerebral blood flow was also analyzed.170 subjects were enrolled (56 migraine with aura, 61 migraine without aura, 53 controls. An incomplete circle of Willis was significantly more common in the migraine with aura compared to control group (73% vs. 51%, p = 0.02, with a similar trend for the migraine without aura group (67% vs. 51%, p = 0.08. Using a quantitative score of the burden of circle of Willis variants, migraine with aura subjects had a higher burden of variants than controls (p = 0.02. Compared to those with a complete circle, subjects with an incomplete circle had greater asymmetry in hemispheric cerebral blood flow (p = 0.05. Specific posterior cerebral artery variants were associated with greater asymmetries of blood flow in the posterior cerebral artery territory.An incomplete circle of Willis is more common in migraine with aura subjects than controls, and is associated with alterations in cerebral blood flow.

  1. Increased brainstem perfusion, but no blood-brain barrier disruption, during attacks of migraine with aura.

    Science.gov (United States)

    Hougaard, Anders; Amin, Faisal M; Christensen, Casper E; Younis, Samaira; Wolfram, Frauke; Cramer, Stig P; Larsson, Henrik B W; Ashina, Messoud

    2017-06-01

    See Moskowitz (doi:10.1093/brain/awx099) for a scientific commentary on this article.The migraine aura is characterized by transient focal cortical disturbances causing dramatic neurological symptoms that are usually followed by migraine headache. It is currently not understood how the aura symptoms are related to the headache phase of migraine. Animal studies suggest that cortical spreading depression, the likely mechanism of migraine aura, causes disruption of the blood-brain barrier and noxious stimulation of trigeminal afferents leading to activation of brainstem nuclei and triggering of migraine headache. We used the sensitive and validated technique of dynamic contrast-enhanced high-field magnetic resonance imaging to simultaneously investigate blood-brain barrier permeability and tissue perfusion in the brainstem (at the level of the lower pons), visual cortex, and brain areas of the anterior, middle and posterior circulation during spontaneous attacks of migraine with aura. Patients reported to our institution to undergo magnetic resonance imaging during the headache phase after presenting with typical visual aura. Nineteen patients were scanned during attacks and on an attack-free day. The mean time from attack onset to scanning was 7.6 h. We found increased brainstem perfusion bilaterally during migraine with aura attacks. Perfusion also increased in the visual cortex and posterior white matter following migraine aura. We found no increase in blood-brain barrier permeability in any of the investigated regions. There was no correlation between blood-brain barrier permeability, brain perfusion, and time from symptom onset to examination or pain intensity. Our findings demonstrate hyperperfusion in brainstem during the headache phase of migraine with aura, while the blood-brain barrier remains intact during attacks of migraine with aura. These data thus contradict the preclinical hypothesis of cortical spreading depression-induced blood-brain barrier

  2. Sublingual piroxicam in migraine without aura.

    Science.gov (United States)

    Ravishankar, K; Tayade, Himanshu; Mandlik, Rahul

    2011-08-01

    The aim of the present study was to compare the analgesic efficacy of a single dose of sublingual piroxicam to that of a placebo during acute attacks of migraine without aura. The drug (N = 30) or a placebo (N = 30) was administered, on randomisation and double-blind basis, to 60 patients between 18 and 50 years of age suffering from migraine without aura. The patients were instructed to take a single tablet sublingually [corresponding to piroxicam 40 mg or placebo] and the severity of the painful symptomatology and associated symptoms were evaluated by this study. The patients treated with sublingual piroxicam showed a significant (P piroxicam administration. In 83.3%, the drug resulted in excellent to good response as compared to only 10% in the placebo group. No local and systemic side effects were reported with sublingual piroxicam. The present study has demonstrated that for the acute management of migraine without aura sublingual piroxicam showed significant analgesic effect with excellent tolerability.

  3. Trigger factors in migraine with aura

    DEFF Research Database (Denmark)

    Hauge, A W; Kirchmann, M; Olesen, J

    2010-01-01

    The aim of the present study was to identify trigger factors in migraine with aura (MA). A total of 629 MA patients representative of the Danish population were sent a questionnaire listing 16 trigger factors thought to be relevant as well as space for free text. Distinction was made between...... attacks with or without aura within each patient. The questionnaire was returned by 522 patients of whom 347 had current MA attacks. In total 80% with current attacks (278/347) indicated that at least one factor triggered their migraine, and 67% (187/278) in this group indicated that they were aware...... of at least one factor often or always giving rise to an attack of MA. Forty-one per cent (113/278) had co-occurring attacks of migraine without aura (MO). Stress (following stress), bright light, intense emotional influences, stress (during stress) and sleeping too much or too little were the trigger factors...

  4. Exploding Head Syndrome as Aura of Migraine with Brainstem Aura: A Case Report.

    Science.gov (United States)

    Rossi, Fabian H; Gonzalez, Elizabeth; Rossi, Elisa Marie; Tsakadze, Nina

    2018-01-01

    This article reports a case of exploding head syndrome (EHS) as an aura of migraine with brainstem aura (MBA). A middle-aged man presented with intermittent episodes of a brief sensation of explosion in the head, visual flashing, vertigo, hearing loss, tinnitus, confusion, ataxia, dysarthria, and bilateral visual impairment followed by migraine headache. The condition was diagnosed as MBA. Explosive head sensation, sensory phenomena, and headaches improved over time with nortriptyline. This case shows that EHS can present as a primary aura symptom in patients with MBA.

  5. Increased brainstem perfusion, but no blood-brain barrier disruption, during attacks of migraine with aura

    DEFF Research Database (Denmark)

    Hougaard, Anders; Amin, Faisal M; Christensen, Casper E

    2017-01-01

    symptoms are related to the headache phase of migraine. Animal studies suggest that cortical spreading depression, the likely mechanism of migraine aura, causes disruption of the blood-brain barrier and noxious stimulation of trigeminal afferents leading to activation of brainstem nuclei and triggering...... of migraine headache. We used the sensitive and validated technique of dynamic contrast-enhanced high-field magnetic resonance imaging to simultaneously investigate blood-brain barrier permeability and tissue perfusion in the brainstem (at the level of the lower pons), visual cortex, and brain areas......-free day. The mean time from attack onset to scanning was 7.6 h. We found increased brainstem perfusion bilaterally during migraine with aura attacks. Perfusion also increased in the visual cortex and posterior white matter following migraine aura. We found no increase in blood-brain barrier permeability...

  6. Avian Pox in Turkey Vulture (Cathartes aura)

    African Journals Online (AJOL)

    Campbell Murn

    Vulture Cathartes aura meridionalis was captured for wing-tagging on San. Francisco, Zulia state, Venezuela. (10°32'15"N, -71°38'10"W). Nodular cutaneous lesions were observed on the head (Figure 1A). Sections of the skin were removed and fixed in 10% buffer formalin and submitted to. Laboratorio de. Diagnostico.

  7. Executive dysfunctions in migraine with and without aura: what is the role of white matter lesions?

    Science.gov (United States)

    Le Pira, Francesco; Reggio, Ester; Quattrocchi, Graziella; Sanfilippo, Cristina; Maci, Tiziana; Cavallaro, Tiziana; Zappia, Mario

    2014-01-01

    Executive dysfunctions and white matter lesions on magnetic resonance imaging have been reported in migraine. The aim of this study was to determine whether any correlation between these 2 variables exists. Forty-four subjects affected by migraine with or without aura were compared with 16 healthy subjects. A battery of neuropsychological tests assessing executive functions was administered to all subjects. Number and total volume of white matter lesions were assessed in the whole brain and in the frontal lobe. The performances of both groups of migraineurs, with and without aura, were significantly worse when compared with controls on Boston Scanning Test. Moreover, we found lower performances compared with controls respectively on Frontal Assessment Battery in patients with migraine with aura and on Controlled Oral Word Association Test in patients with migraine without aura. Nineteen patients (43.2%) and one control subject (6.2%) had white matter lesions. We did not find any significant correlation between white matter lesions load and neuropsychological performances. On the basis of our results, white matter lesions load on magnetic resonance imaging do not seem to contribute to neuropsychological performances deficit in migraineurs. © 2013 American Headache Society.

  8. Aura-like features and photophobia in sightless migraine patients

    Directory of Open Access Journals (Sweden)

    Greice Cardoso de Carvalho Silva

    2014-12-01

    Full Text Available Migraine is a central nervous system disorder frequently expressed with paroxysmal visual dysfunctions. Objective To test the hypothesis that normal visual input is vital for the migrainous aura and photophobia. Method We studied the migraine-related visual disturbances in 8 sightless migraineurs identified among 200 visually impaired subjects. Results The main findings were the visual aura and photophobia disappearance along with blindness development, the oddness of aura – too short, colourful (e.g. blue or fire-like, auditory in nature or different in shape (round forms – and the lack of photophobia. Conclusion We propose that the aura duration should be accepted as shorter in visually impaired subjects. The changes in aura phenotype observed in our patients may be the result of both cerebral plasticity induced by the visual impairment and/or the lack of visual input per se. Integrity of visual pathways plays a key role in migraine visual aura and photophobia.

  9. Early data from Aura and continuity from UARS and TOMS

    NARCIS (Netherlands)

    Hilsenrath, E.; Schoeberl, M.R.; Douglass, A.R.; Bhartia, P.K.; Barnett, J.J.; Beer, R.; Waters, J.W.; Gunson, M.R.; Froidevaux, L.; Gille, J.C.; Levelt, P.F.

    2006-01-01

    Aura, the last of the large EOS observatories, was launched on July 15, 2004. Aura is designed to make comprehensive stratospheric and tropospheric composition measurements from its four instruments, HIRDLS, MLS, OMI and TES. These four instruments work in synergy to provide data on ozone trends,

  10. On the methodology of drug trials in migraine with aura

    DEFF Research Database (Denmark)

    Hauge, Anne Werner; Hougaard, Anders; Olesen, Jes

    2010-01-01

    for future inquiry. We make recommendations about subject selection; the choice, definition and assessment of outcome measures; optimal treatments in relation to aura and headache; and we provide samples of study report forms used to record occurrence of aura and headache in this population....

  11. No abnormalities of intrinsic brain connectivity in the interictal phase of migraine with aura

    DEFF Research Database (Denmark)

    Hougaard, Anders; Amin, F M; Magon, S

    2015-01-01

    if cortical dysfunction is present at rest, i.e. in the absence of any external stimuli. Functional magnetic resonance imaging is a powerful technique for evaluating resting state functional connectivity, i.e. coherence of brain activity across cerebral areas. The objective of this study was to investigate...... resting-state functional brain connectivity in migraineurs with aura outside of attacks using functional magnetic resonance imaging. METHODS: Forty patients suffering from migraine with visual aura and 40 individually age and gender matched healthy controls with no history or family history of migraine......, and in a data-driven exploratory fashion (dual regression) in order to reveal any possible between-group differences of resting state networks. Age, gender, attack frequency and disease duration were included as nuisance variables. RESULTS: No differences of functional connectivity were found between patients...

  12. Can migraine aura be provoked experimentally? A systematic review of potential methods for the provocation of migraine aura

    DEFF Research Database (Denmark)

    Lindblad, Marianne; Hougaard, Anders; Amin, Faisal Mohammad

    2017-01-01

    , physical activity, calcitonin gene-related peptide infusion, chocolate ingestion, and the intravenous injection of insulin. In addition, carotid artery puncture has consistently been reported as a trigger of aura. Conclusions No safe and efficient method for aura provocation exists at present, but several...

  13. MLS/Aura L2 Geopotential Height V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2GPH is the EOS Aura Microwave Limb Sounder (MLS) standard product for geopotential height derived from radiances measured by the 118 and 240 GHz radiometers. The...

  14. MLS/Aura L2 Geopotential Height V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2GPH is the EOS Aura Microwave Limb Sounder (MLS) standard product for geopotential height derived from radiances measured by the 118 and 240 GHz radiometers. The...

  15. Migraine aura pathophysiology: the role of blood vessels and microembolisation

    OpenAIRE

    Dalkara, Turgay; Nozari, Ala; Moskowitz, Michael A

    2010-01-01

    Migraine attacks with auras are sometimes associated with underlying hereditary or acquired cerebrovascular disorders. A unifying pathophysiological explanation linking migraine to these conditions has been diffcult to identify. On the basis of genetic and epidemiological evidence, we suggest that changes in blood vessels, hypoperfusion disorders, and microembolisation can cause neurovascular dysfunction and evoke cortical spreading depression, an event that is widely thought to underlie aura...

  16. The clinical presentation and diagnosis of epileptic autonomic auras

    Directory of Open Access Journals (Sweden)

    Marina Revditovna Kremenchugskaya

    2012-01-01

    Full Text Available Objective: to refine the pattern of clinical manifestations of epileptic autonomic auras (EAA and to reveal clinical, electroencephalographic, and neuroimaging ratios. Patients and methods. Eighteen patients (8, 41% men and 10, 59% women aged 9 to 27years (mean 18±5years were examined. The examination encompassed analysis of history data, clinical and neurological studies, long-term video-assisted electroencephalographic monitoring, and magnetic resonance imaging (MRI of the brain. Results. In most patients (n = 12, 67%, the symptoms of EAA corresponded to the criteria for abdominal one. In the other patients, the clinical manifestations resembled autonomic paroxysms as attacks of panic. Interictal pathological changes on an electroencephalogram (EEG were present in the frontal, temporal, and frontotemporal regions in 4 (22%, 6 (33%, and 7 (39% patients, respectively, as well as in both the left and right hemispheres without significant differences. Pathological EEG changes were not found in one case. MRI detected that 13 (72% patients had structural changes that were potentially eliptogenic. Conclusion. The clinical symptoms of EAA give information on the site of a primary pathological focus. It is necessary to differentiate EAA from non-epileptic paroxysmal states. The autonomic phenomena of epileptic genesis help study the functional organizations of the autonomic nervous system.

  17. [A case of focal epilepsy manifesting multiple psychiatric auras].

    Science.gov (United States)

    Ezura, Michinori; Kakisaka, Yosuke; Jin, Kazutaka; Kato, Kazuhiro; Iwasaki, Masaki; Fujikawa, Mayu; Aoki, Masashi; Nakasato, Nobukazu

    2015-01-01

    We present a case of epilepsy with multiple types of focal seizures that were misdiagnosed as psychiatric disorders. A 20-year-old female patient presented with a variety of episodes, including loss of consciousness, deja vu, fear, delusion of possession, violent movements, and generalized convulsions. Each of these symptoms appeared in a stereotypic manner. She was initially diagnosed with a psychiatric disorder and treated with psychoactive medications, which had no effect. Long-term video electroencephalography revealed that her episodes of violent movement with impaired consciousness and secondarily generalized seizure were epileptic events originating in the right hemisphere. High-field brain magnetic resonance imaging for detecting subtle lesions revealed bilateral lesions from periventricular nodular heterotopia. Her final diagnosis was right hemispheric focal epilepsy. Carbamazepine administration was started, which successfully controlled all seizures. The present case demonstrates the pitfall of diagnosing focal epilepsy when it presents with multiple types of psychiatric aura. Epilepsy should thus be included in differential diagnoses, considering the stereotypic nature of symptoms, to avoid misdiagnosis.

  18. Variability of clinical features in attacks of migraine with aura

    DEFF Research Database (Denmark)

    Hansen, Jakob M; Goadsby, Peter J; Charles, Andrew C

    2016-01-01

    . CONCLUSION: These findings are consistent with variable involvement of different brain regions during a migraine attack. The variable occurrence of nausea, and phonophobia in conjunction with photophobia, both defining features of migraine, may be an important consideration in designing clinical studies......BACKGROUND: There is significant variability in the clinical presentation of migraine, both among patients, and between attacks in an individual patient. We examined clinical features of migraine with aura in a large group of patients enrolled in a clinical trial, and compared retrospective...... a detailed retrospective description of the clinical features of their attacks of migraine. During the trial, clinical symptoms in migraine attacks starting with aura were recorded prospectively in 861 attacks. RESULTS: Retrospectively reported visual aura symptoms were variable and often overlapping...

  19. Migraine with visual aura associated with thicker visual cortex

    DEFF Research Database (Denmark)

    Gaist, David; Hougaard, Anders; Garde, Ellen

    2018-01-01

    Until recent years it was believed that migraine with aura was a disorder causing intermittent neurological symptoms, with no impact on brain structure. However, recent MRI studies have reported increased cortical thickness of visual and somatosensory areas in patients with migraine with aura...... number of subjects. In this cross-sectional study, we recruited females aged 30-60 years from the nationwide Danish Twin Registry. Brain MRI of females with migraine with aura (patients), their co-twins, and unrelated migraine-free twins (controls) were performed at a single centre and assessed...... for cortical thickness in predefined cortical areas (V1, V2, V3A, MT, somatosensory cortex), blinded to headache diagnoses. The difference in cortical thickness between patients and controls adjusted for age, and other potential confounders was assessed. Comparisons of twin pairs discordant for migraine...

  20. Magnetic resonance angiography of intracranial and extracranial arteries in patients with spontaneous migraine without aura

    DEFF Research Database (Denmark)

    Amin, Faisal Mohammad; Asghar, Mohammad Sohail; Hougaard, Anders

    2013-01-01

    Extracranial arterial dilatation has been hypothesised to be the cause of pain in patients who have migraine without aura. To test that hypothesis, we aimed to measure extracranial and intracranial arteries during attacks of migraine without aura....

  1. Persistent Visual Aura following Catheter Ablation in a Patient with WPW Syndrome

    Directory of Open Access Journals (Sweden)

    Shinichi Koyama

    2007-01-01

    Full Text Available We report a patient who has had persistent visual disturbances since she underwent catheter ablation to treat her Wolff-Parkinson-White (WPW syndrome. We examined her visual symptoms carefully and quantitatively by means of our newly developed method combining image-processing and psychophysics. We first simulated the patient’s visual symptoms using image-processing techniques. Since the simulation indicated that she would be very sensitive to the edges of the visual stimuli, we evaluated her sensitivity to the edges using psychophysics. The results indicated that she was hypersensitive to the clear-cut edges of the visual stimuli. Her visual symptoms were very similar to those of visual aura of migraine, rather than those of photosensitive epilepsy. Magnetic resonance imaging (MRI and single photon emission computed tomography (SPECT, electroenchepalogram (EEG, and visual-evoked potentials (VEP in the patient were normal. No abnormalities in her fundus, visual field, or electroretinogram were found, either. Transesophageal echocardiography with bubble study indicated that she had a preexisting right-to-left shunt. We hypothesize that visual aura of migraine was triggered and made persistent by the catheter ablation in this patient. Although the relationship between migraine, catheter ablation, and right-to-left shunts is unknown, previous studies on the transcatheter closure of patent foramen ovale suggest a possible link between them. Catheter ablation in patients with migraine and preexisting shunts may lead to exacerbations in migraine symptoms.

  2. Exploiting Aura OMI Level 2 Data with High Resolution Visualization

    Science.gov (United States)

    Wei, J. C.; Yang, W.; Johnson, J. E.; Zhao, P.; Gerasimov, I. V.; Pham, L.; Vicente, G. A.; Shen, S.

    2014-12-01

    Satellite data products are important for a wide variety of applications that can bring far-reaching benefits to the science community and the broader society. These benefits can best be achieved if the satellite data are well utilized and interpreted, such as model inputs from satellite, or extreme event (such as volcano eruption, dust storm, …etc) interpretation from satellite. Unfortunately, this is not always the case, despite the abundance and relative maturity of numerous satellite data products provided by NASA and other organizations. One way to help users better understand the satellite data is to provide data along with 'Images', including accurate pixel-level (Level 2) information, pixel coverage area delineation, and science team recommended quality screening for individual geophysical parameters. Goddard Earth Sciences Data and Information Services Center (GES DISC) always strives to best support (i.e., Software-as-a-service, SaaS) the user-community for NASA Earth Science Data. In this case, we will present a new visualization tool that helps users exploiting Aura Ozone Monitoring Instrument (OMI) Level 2 data. This new visualization service utilizes Open Geospatial Consortium (OGC) standard-compliant Web Mapping Service (WMS) and Web Coverage Service (WCS) calls in the backend infrastructure. The functionality of the service allows users to select data sources (e.g., multiple parameters under the same measurement, like NO2 and SO2 from OMI Level 2 or same parameter with different methods of aggregation, like NO2 in OMNO2G and OMNO2D products), defining area-of-interest and temporal extents, zooming, panning, overlaying, sliding, and data subsetting and reformatting. The interface will also be able to connect to other OGC WMS and WCS servers, which will greatly enhance its expandability to integrate additional outside data/map sources (such as Global Imagery Browse Services (GIBS)).

  3. The occurrence and characteristics of auras in a large epilepsy cohort

    DEFF Research Database (Denmark)

    Nakken, K O; Solaas, M H; Kjeldsen, M J

    2009-01-01

    = 1897) and 39% of those with active epilepsy (n = 765) had experienced an aura. Six percent reported more than one type. Non-specified auras were most frequently reported (35%), followed by somatosensory (11%) and vertiginous (11%). While the majority of those reporting auras (59%) had focal epilepsies...... is underestimated, especially in children and those with learning disabilities....

  4. Cryptocoryne aura (Araceae), a new species from West Kalimantan, Indonesia

    DEFF Research Database (Denmark)

    Wongso, Suwidji; Ipor, Isa B.; Tawan, Cheksum S.

    2016-01-01

    A new species, Cryptocoryne aura Wongso & Ipor, from West Kalimantan, Indonesia, is described and illustrated. It differs from other Cryptocoryne species primarily by having a transparent, ciliate membrane along the leaf margin and a short spathe with a yellow, forward-twisted limb. It has...

  5. Tsemendirahva kolmekordne pidu / Tapio Aura, Aleksander Nikolajev ; interv. Sulev Oll

    Index Scriptorium Estoniae

    Aura, Tapio

    2005-01-01

    Kunda tsemenditootmisel täitus 135 aastat ja Kunda sadamal 200 aastat. Oma ettevõtete käekäigust räägivad AS-i Kunda Nordic Tsement tegevdirektor Tapio Aura ja Kunda sadama direktor Aleksander Nikolajev

  6. Epileptic aura and perception of self-control

    DEFF Research Database (Denmark)

    Lohse, Allan; Kjaer, Troels W; Sabers, Anne

    2015-01-01

    OBJECTIVE: The health locus of control is the subjective perception of control over one's health. It has been studied for years as one of several factors that determine patient health-related behaviors. The aim of this study was to investigate how the epileptic aura is associated with the health...

  7. Anatomical alterations of the visual motion processing network in migraine with and without aura.

    Directory of Open Access Journals (Sweden)

    Cristina Granziera

    2006-10-01

    Full Text Available Patients suffering from migraine with aura (MWA and migraine without aura (MWoA show abnormalities in visual motion perception during and between attacks. Whether this represents the consequences of structural changes in motion-processing networks in migraineurs is unknown. Moreover, the diagnosis of migraine relies on patient's history, and finding differences in the brain of migraineurs might help to contribute to basic research aimed at better understanding the pathophysiology of migraine.To investigate a common potential anatomical basis for these disturbances, we used high-resolution cortical thickness measurement and diffusion tensor imaging (DTI to examine the motion-processing network in 24 migraine patients (12 with MWA and 12 MWoA and 15 age-matched healthy controls (HCs. We found increased cortical thickness of motion-processing visual areas MT+ and V3A in migraineurs compared to HCs. Cortical thickness increases were accompanied by abnormalities of the subjacent white matter. In addition, DTI revealed that migraineurs have alterations in superior colliculus and the lateral geniculate nucleus, which are also involved in visual processing.A structural abnormality in the network of motion-processing areas could account for, or be the result of, the cortical hyperexcitability observed in migraineurs. The finding in patients with both MWA and MWoA of thickness abnormalities in area V3A, previously described as a source in spreading changes involved in visual aura, raises the question as to whether a "silent" cortical spreading depression develops as well in MWoA. In addition, these experimental data may provide clinicians and researchers with a noninvasively acquirable migraine biomarker.

  8. Distinctive anatomical and physiological features of migraine aura revealed by 18 years of recording

    DEFF Research Database (Denmark)

    Hansen, Jakob Møller; Baca, Serapio Michael; Vanvalkenburgh, Paul

    2013-01-01

    insight into basic aura mechanisms. An individual made detailed drawings of his visual percept of migraine aura in real time during more than 1000 attacks of migraine aura without headache over 18 years. Drawings were made in a consistent fashion documenting the shape and location of the aura wavefront...... originated centrally (within 10° eccentricity), but there were also other distinct sites of initiation in the visual field. Auras beginning centrally preferentially propagated first through lower nasal field (69-77% of all auras) before travelling to upper and temporal fields, on both sides. Some auras...... propagated from peripheral to central regions of the visual field-these typically followed the reverse path of those travelling in the opposite direction. The mean velocity of the perceived visual phenomenon did not differ between attacks starting peripherally and centrally. The estimated speed...

  9. [Migraine with aura and patent foramen ovale. A different clinical entity].

    Science.gov (United States)

    Ramírez-Moreno, J M; Casado-Naranjo, I; Gómez, M; Portilla, Jc; Caballero, M; Serrano, A; Ojalvo, M J; Falcón, A; Tena-Mora, D; Calle, M

    2008-10-01

    This work has aimed to evaluate the prevalence of patent foramen ovale in subjects with migraine with aura by transcranial contrast doppler and to describe the clinical and risk profile of these patients. We performed a transcranial contrast doppler in 94 consecutive out-patients with migraine with aura (MWA) in a neurology outpatient clinic. They were divided into two groups according to the presence of patent foramen ovale: MWA_RLsh (with right-to-left shunt) and MWA_RLNsh (without right-to-left shunt). Differences between the groups were analyzed according to endpoints of age, gender, clinical severity, aura type and attacks frequency, comorbility, cardiovascular risk factors (CVRFs), neuroimaging findings, severity of shunt and treatment. n=94; MWA_RLsh: 47 (54%). MWA_RLNsh: 40 (46%). Age: 33.13; standard desviation (SD): 10.8 vs 33.496; SD: 11.2; p=0.728. Female: 66 vs 72.5%; p=0.511. Visual aura: 73.9% vs 78.9%; p=0.921. There were no significant differences in regards to the risk factors studied or to the comorbid diseases that are associated to migraine. The patients with patent foramen ovale have an odds ratio (OR) of ischemic stroke: 1.189 (95% confidence interval [CI]: 0.226 to 6.248; p=0.840), OR for subclinical brain lesions in cranial magnetic resonance imaging (MRI): 0.589 (95% CI: 0.193 to 1.799; p=0.35) and OR for combined previous ischemic stroke and subclinical brain lesions: 0.745 (95% CI: 0.261 to 2.129; p=0.58). Migraine attack frequency >1 per month: 27.9 vs 36.4; p=0.464. Need for prophylaxis therapy: 44.7 vs 57.7%; p=0.284. Both groups are similar regarding their clinical profile. We did not find a greater prevalence of stroke or silent brain lesions in the group with positive shunt..

  10. Prospective testing of ICHD-3 beta diagnostic criteria for migraine with aura and migraine with typical aura in patients with transient ischemic attacks

    DEFF Research Database (Denmark)

    Lebedeva, Elena R; Gurary, Natalia M; Gilev, Denis V

    2018-01-01

    Introduction The International Classification of Headache Disorders 3rd edition beta (ICHD-3 beta) gave alternative diagnostic criteria for 1.2 migraine with aura (MA) and 1.2.1 migraine with typical aura (MTA) in the appendix. The latter were presumed to better differentiate transient ischemic...

  11. Matrix metalloproteinases during and outside of migraine attacks without aura

    DEFF Research Database (Denmark)

    Ashina, M.; Tvedskov, J.F.; Thiesen, Kerstin Lipka

    2010-01-01

    Ashina M, Tvedskov JF, Lipka K, Bilello J, Penkowa M & Olesen J. Matrix metalloproteinases during and outside of migraine attacks without aura. Cephalalgia 2009. London. ISSN 0333-1024To test the hypothesis that permeability of the blood-brain barrier (BBB) is altered during migraine attack due...... to enhanced activation of matrix metalloproteinases (MMPs), we investigated MMP-3, MMP-9 and tissue inhibitor of metalloproteases (TIMP)-1 in the external jugular vein during and outside of migraine attacks in 21 patients with migraine without aura. In addition, we measured plasma levels of several other...... of MMP-3 in the external jugular (P = 0.002) and cubital (P = 0.008) vein during attacks compared with outside of attacks. We found no correlation of ictal or interictal MMP-3, MMP-9 and TIMP-1 to migraine duration and frequency analysed in 21 patients (P > 0.05). There was no difference between ictal...

  12. Dipyridamole may induce migraine in patients with migraine without aura

    DEFF Research Database (Denmark)

    Kruuse, C; Lassen, L H; Iversen, Helle Klingenberg

    2006-01-01

    Dipyridamole inhibits phosphodiesterase 5 (PDE5) and adenosine re-uptake. The most prominent side-effect is headache. We examined the migraine-generating effects of dipyridamole as well as the cerebral blood velocity response in a single-blind study, including 10 patients with migraine without aura...... repeatedly. Headache was induced in all migraine patients and in eight of 10 healthy subjects (P = 0.47) with no significant difference in headache intensity (P = 0.53). However, five patients but only one healthy subject experienced the symptoms of migraine without aura, according to ICHD-2 criteria, within....... Thus, dipyridamole induces symptoms of migraine and an initial decrease in V(mca) in migraine patients, but not significantly more than in healthy subjects. This relatively low frequency of migraine induction, compared with nitric oxide donors and sildenafil, is probably due to the less specific action...

  13. Obisdian sourcing by PIXE analysis at AURA2

    International Nuclear Information System (INIS)

    Neve, S.R.; Barker, P.H.; Holroyd, S.; Sheppard, P.J.

    1994-01-01

    The technique of Proton Induced X-ray Emission is a suitable method for the elemental analysis of obsidian samples and artefacts. By comparing the elemental composition of obsidian artefacts with those of known sources of obsidian and identifying similarities, the likely origin of the sample can be discovered and information about resource procurement gained. A PIXE facility has now been established at the Auckland University Research Accelerator Laboratory, AURA2. It offers a rapid, multi-element, non-destructive method of characterisation of obsidian samples ranging from small chips to large pieces. In an extensive survey of Mayor Island obsidian, a discrimination has been made between the different locations of obsidian deposits on the island. In addition, using the database developed at AURA2, artefacts from the site of Opita, Hauraki Plains, have been sourced. (Author). 18 refs., 8 figs., 7 tabs., 1 appendix

  14. Aqua/Aura Updated Inclination Adjust Maneuver Performance Prediction Model

    Science.gov (United States)

    Boone, Spencer

    2017-01-01

    This presentation will discuss the updated Inclination Adjust Maneuver (IAM) performance prediction model that was developed for Aqua and Aura following the 2017 IAM series. This updated model uses statistical regression methods to identify potential long-term trends in maneuver parameters, yielding improved predictions when re-planning past maneuvers. The presentation has been reviewed and approved by Eric Moyer, ESMO Deputy Project Manager.

  15. Patients with migraine with aura have increased flow mediated dilation

    Directory of Open Access Journals (Sweden)

    Altamura Claudia

    2010-03-01

    Full Text Available Abstract Background Endothelium-derived nitric oxide (NO mediates the arterial dilation following a flow increase (i.e. flow-mediated dilation, FMD, easily assessed in the brachial artery. NO is also involved in cerebral hemodynamics and it is supposed to trigger vascular changes occurring during migraine. This study aimed at investigating whether migraine patients present an altered response to NO also in the peripheral artery system. Methods We enrolled 21 migraineurs (10 with aura [MwA], 11 without aura [MwoA], and 13 controls. FMD was evaluated with ultrasound in all subjects by measuring the percentage increase of the brachial artery diameter induced by hyperaemia reactive to sustained cuff inflation around the arm above systolic pressure. FMD values were then normalized for shear stress. Results Normalized FMD values were higher in patients with MwA (28.5 10-2%.s than in controls (9.0 10-2%.s and patients with MwoA (13.7 10-2%.s (p Conclusions Migraineurs with aura present an excessive arterial response to hyperaemia, likely as an effect of an increased sensitivity to endothelium-derived nitric oxide. This phenomenon observed peripherally might reflect similar characteristics in the cerebral circulation.

  16. Exploding head syndrome followed by sleep paralysis: a rare migraine aura.

    Science.gov (United States)

    Evans, Randolph W

    2006-04-01

    A 26-year-old patient is described with a unique migraine aura. She described an 8-year history of episodes occurring 1 to 2 times yearly of exploding head syndrome followed by sleep paralysis followed by a migraine headache. She also had identical headaches without aura about once per week. Both aura symptoms, which may occur in the brainstem, resulted in activation of the trigeminovascular system through an unknown mechanism.

  17. Aura fractal, fins da arte e capitalismo primitivista

    Directory of Open Access Journals (Sweden)

    Leonardo Carvalho Bertolossi

    2017-10-01

    Full Text Available Objetiva-se refletir sobre as relações entre as artes visuais e a antropologia a partir do texto seminal de Walter Benjamin sobre a aura para pensar sobre as finalidades e os fins da metafísica da arte no Ocidente diante dos diagnósticos de fim de mundo/fim da história da arte, e da vitória do espetáculo e da indústria cultural no capitalismo contemporâneo. O artigo apresenta alguns dos sentidos da arte no mundo ocidental e em especial no romantismo, avança sobre a crise e o fim dos modelos estruturais e cognitivos do pensamento artístico moderno, destaca o interesse pela política e pela vida, e se indaga sobre a retomada do primitivismo nas artes visuais e na antropologia contemporânea como redenção e renovação das mortes anunciadas. ABSTRACT The objective is to reflect on the relations between the visual arts and anthropology from Walter Benjamin's seminal text on the aura to think about the purposes and ends of the metaphysics of art in the West in the face of end-of-world/end-of-art history, and the victory of spectacle and cultural industry in contemporary capitalism. The article presents some of the meanings of art in the Western world and especially in Romanticism, advances on the crisis and the end of the structural and cognitive models of modern artistic thought, highlights the interest in politics and life, and inquires about the resumption of Primitivism in the visual arts and contemporary anthropology as redemption and renewal of the announced deaths. KEYWORDS Anthropology of art, aura, soul, thanatology, primitivism

  18. Site Protection Efforts at the AURA Observatory in Chile

    Science.gov (United States)

    Smith, R. Chris; Smith, Malcolm G.; Sanhueza, Pedro

    2015-08-01

    The AURA Observatory (AURA-O) was the first of the major international observatories to be established in northern Chile to exploit the optimal astronomical conditions available there. The site was originally established in 1962 to host the Cerro Tololo Inter-American Observatory (CTIO). It now hosts more than 20 operational telescopes, including some of the leading U.S. and international astronomical facilities in the southern hemisphere, such as the Blanco 4m telescope on Cerro Tololo and the Gemini-South and SOAR telescopes on Cerro Pachón. Construction of the next generation facility, the Large Synoptic Survey Telescope (LSST), has recently begun on Cerro Pachón, while additional smaller telescopes continue to be added to the complement on Cerro Tololo.While the site has become a major platform for international astronomical facilities over the last 50 years, development in the region has led to an ever-increasing threat of light pollution around the site. AURA-O has worked closely with local, regional, and national authorities and institutions (in particular with the Chilean Ministries of Environment and Foreign Relations) in an effort to protect the site so that future generations of telescopes, as well as future generations of Chileans, can benefit from the dark skies in the region. We will summarize our efforts over the past 15 years to highlight the importance of dark sky protection through education and public outreach as well as through more recent promotion of IDA certifications in the region and support for the World Heritage initiatives described by others in this conference.

  19. Headache as an Aura of Epilepsy: Video-EEG Monitoring Study.

    Science.gov (United States)

    Kim, Dong Wook; Sunwoo, Jun-Sang; Lee, Sang Kun

    2016-04-01

    Headache can be associated with epilepsy as a pre-ictal, ictal, or post-ictal phenomenon; however, studies of patients with headache as an epileptic aura are scarce. We performed the present study to investigate the incidence and characteristics of headache as an epileptic aura, via confirmation of electroencephalography (EEG) changes by video-EEG monitoring. Data of aura and clinical seizure episodes of 831 consecutive patients who undertook video-EEG monitoring were analyzed retrospectively. For patients who had headache as an aura, information on the detailed features of headache was acquired, including location, nature, duration, and the presence of accompanying symptoms. Video-recorded clinical seizures, EEG findings, and neuroimaging data were used to determine the ictal onset areas in the patients. Six out of 831 (0.7%) patients experienced headache as aura (age range, 25-52 years), all of whom had partial seizures. The incidence of pre-ictal headache was 6.3% (25/831), and post-ictal headache was 30.9% (257/831). In patients with headache as aura, five patients described headache as the most frequent aura, and headache was the second most frequent aura in one patient. The characteristics of headache were hemicrania epileptica in two patients, tension-type headache in another two patients, and migraine-like headache in the remaining two patients. No patient met the diagnostic criteria of ictal epileptic headache or migraine aura-triggered seizure. Our study showed that headache as an aura is uncommon in adult patients with epilepsy, and that headache can present as diverse features, including hemicrania epileptica, tension-type headache, and migraine-like headache. Further studies are necessary to characterize the features of headache as an epileptic aura in adult patients with epilepsy. © 2016 American Headache Society.

  20. The Efficacy of Air Pollution Control Efforts: Evidence from AURA

    Science.gov (United States)

    Dickerson, Russell R.; Canty, Tim; Duncan, Bryan N.; Hao, He; Krotkov, Nickolay A.; Salawitch, Ross J.; Stehr, Jeffrey W.; Vinnikov, Konstatin

    2014-01-01

    Observations of NO2, SO2, and H2CO from OMI on AURA provide an excellent record of pollutant concentrations for the past decade. Abatement strategies to control criteria pollutants including ozone and fine particulate matter (PM2.5) have met with varying degrees of success. Sulfur controls had a profound impact on local SO2 concentrations and a measurable impact on PM2.5. Although substantial effort has gone into VOC control, ozone in the eastern US has responded dramatically to NOx emissions controls.

  1. OMI/Aura Ozone (O3) Total Column 1-Orbit L2 Swath 13x24 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura Level-2 Total Column Ozone Data Product OMTO3 (Version 003) is made available (http://disc.gsfc.nasa.gov/Aura/OMI/omto3_v003.shtml) from the NASA...

  2. OMI/Aura Formaldehyde (HCHO) Total Column Global 0.25deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Version-3 Aura-OMI Formaldehyde Product OMHCHOG is now available (http://disc.gsfc.nasa.gov/Aura/OMI/omhchog_v003.shtml) from the NASA Goddard Earth Sciences...

  3. Migraineurs without aura show microstructural abnormalities in the cerebellum and frontal lobe.

    Science.gov (United States)

    Granziera, C; Romascano, D; Daducci, A; Roche, A; Vincent, M; Krueger, G; Hadjikhani, N

    2013-12-01

    The involvement of the cerebellum in migraine pathophysiology is not well understood. We used a biparametric approach at high-field MRI (3 T) to assess the structural integrity of the cerebellum in 15 migraineurs with aura (MWA), 23 migraineurs without aura (MWoA), and 20 healthy controls (HC). High-resolution T1 relaxation maps were acquired together with magnetization transfer images in order to probe microstructural and myelin integrity. Clusterwise analysis was performed on T1 and magnetization transfer ratio (MTR) maps of the cerebellum of MWA, MWoA, and HC using an ANOVA and a non-parametric clusterwise permutation F test, with age and gender as covariates and correction for familywise error rate. In addition, mean MTR and T1 in frontal regions known to be highly connected to the cerebellum were computed. Clusterwise comparison among groups showed a cluster of lower MTR in the right Crus I of MWoA patients vs. HC and MWA subjects (p = 0.04). Univariate and bivariate analysis on T1 and MTR contrasts showed that MWoA patients had longer T1 and lower MTR in the right and left pars orbitalis compared to MWA (p < 0.01 and 0.05, respectively), but no differences were found with HC. Lower MTR and longer T1 point at a loss of macromolecules and/or micro-edema in Crus I and pars orbitalis in MWoA patients vs. HC and vs. MWA. The pathophysiological implications of these findings are discussed in light of recent literature.

  4. Pattern reversal visual evoked potentials in migraine subjects without aura

    Directory of Open Access Journals (Sweden)

    Pedro F. Moreira Filho

    1994-12-01

    Full Text Available Twenty seven patients with migraine without aura were investigated. The age was between 12 and 54 years; 5 were men and 22 women. The diagnosis of migraine was made according to the classification proposed by the International Headache Society. The method of visual evoked potential was performed with pattern reversal (VEP-PR, with monocular stimulation. The stimulation was performed with pattern reversal with 4x4 cm black and white and red and green squared screen placed 1 meter from the nasion at stimulus frequency 1/s; 128 individual trials were analysed. The VEP-PR with black/white and red/green study showed a significant increase of value of the P-100 latency in 10 migraine patients. In 8 cases the LP100 in VEP-PR black/white was normal but in VEP-PR red/green the LP100 showed increase. Specifically in 1 of our cases, LP100 were normal in VEP-PR black/white but in the red/green there were no reproductice waves. On basis of these observations we consider that the method of VEP-PR is an useful instrument for investigation of migraine patients without aura.

  5. Elevated audiovisual temporal interaction in patients with migraine without aura

    Science.gov (United States)

    2014-01-01

    Background Photophobia and phonophobia are the most prominent symptoms in patients with migraine without aura. Hypersensitivity to visual stimuli can lead to greater hypersensitivity to auditory stimuli, which suggests that the interaction between visual and auditory stimuli may play an important role in the pathogenesis of migraine. However, audiovisual temporal interactions in migraine have not been well studied. Therefore, our aim was to examine auditory and visual interactions in migraine. Methods In this study, visual, auditory, and audiovisual stimuli with different temporal intervals between the visual and auditory stimuli were randomly presented to the left or right hemispace. During this time, the participants were asked to respond promptly to target stimuli. We used cumulative distribution functions to analyze the response times as a measure of audiovisual integration. Results Our results showed that audiovisual integration was significantly elevated in the migraineurs compared with the normal controls (p audiovisual suppression was weaker in the migraineurs compared with the normal controls (p < 0.05). Conclusions Our findings further objectively support the notion that migraineurs without aura are hypersensitive to external visual and auditory stimuli. Our study offers a new quantitative and objective method to evaluate hypersensitivity to audio-visual stimuli in patients with migraine. PMID:24961903

  6. What's NEW at the GES DISC: Evolution of Data Management and Services for Aura Mission and Beyond

    Science.gov (United States)

    Wei, Jennifer

    2016-01-01

    GES DISC world. Aura data usage and trend. Aura data users requests. GES DISC update (before/after); New Access method (ftp to http) with Earthdata Login System, New Website (DISC/Mirador to New Interface), New Giovanni (Giovanni to Now Federated). GES DISC support beyond Aura Mission; Multi-sensor coincident data subsets, Level 2 support (Sub-setter, Visualization), Data List.

  7. Walter Benjamin's concept of aura and the cultural industry

    Directory of Open Access Journals (Sweden)

    Bráulio Santos Rabelo de Araújo

    2010-12-01

    Full Text Available Trata-se de uma análise do texto A obra de arte na era da reprodutibilidade técnica, de 1935, de Walter Benjamin, no qual o autor analisa as alterações provocadas pelas novas técnicas de produção artística na esfera da cultura, e desenvolve, como elemento principal, a tese de a reprodutibilidade técnica provocar a superação da aura pela obra de arte. Tendo como apoio o contraste do texto de Benjamin com o texto A indústria cultural: O esclarecimento como mistificação das massas, de Theodor Adorno e Max Horkheimer, de 1947, e a observação da produção do cinema, da música e do livro (artes necessariamente reprodutíveis, este artigo (a analisa a tese da superação do conceito de aura pela obra de arte na era da reprodutibilidade técnica, (b contrasta essa tese com a reflexão sobre indústria cultural de Adorno e Horkheimer e com as características da obra de arte produzida no decorrer do século 20 e início do século 21, e (c apresenta as contribuições que podem ser retiradas dessa análise para a atual reflexão a respeito dos impactos da Internet e das tecnologias digitais sobre a produção cultural contemporânea. Como resultado principal e do qual decorre outras conclusões, o artigo considera que as técnicas analisadas por Benjamin, apesar de terem tornado a obra de arte independente de um substrato único, não a emanciparam de seu caráter aurático. Os elementos centrais da aura (autenticidade e unicidade não foram superados, mas, ao contrário, adaptaram-se às mudanças técnicas, adaptação essa que ocorreu em torno da industrialização, a qual marcou a produção cultural no século 20.

  8. Epileptic auras and their role in driving safety in people with epilepsy.

    Science.gov (United States)

    Punia, Vineet; Farooque, Pue; Chen, William; Hirsch, Lawrence J; Berg, Anne T; Blumenfeld, Hal

    2015-11-01

    The aim of our study was to evaluate the role of auras in preventing motor vehicle accidents (MVAs) among patients with medically refractory epilepsy. The Multicenter Study of Epilepsy Surgery database was used to perform a case-control study by identifying patients who had seizures while driving that led to MVAs (cases) and those who had seizures while driving without MVAs (controls). We compared presence of reliable auras and other aura-related features between the two groups. Two hundred fifteen of 553 patients reported having seizure(s) while driving; 74 were identified as "controls" and 141 as "cases." The two groups had similar demographic and clinical features. The presence of reliable auras was not different between the two groups (67% in cases vs. 65% in controls; odds ratio [OR] 0.89, 95% confidence interval [CI] 0.49-1.61, p = 0.76). In addition, the groups did not differ in the proportion of patients who reported longer (>1 min) auras (OR 0.7, 95% CI 0.28-1.76, p = 0.47), or who thought that their auras were of sufficient duration to be protective (OR 1.19, 95% CI 0.62-2.00, p = 0.77). Our study questions the long-held belief of a protective role of reliable auras against MVAs in people with epilepsy. Wiley Periodicals, Inc. © 2015 International League Against Epilepsy.

  9. Summary of Aqua, Aura, and Terra High Interest Events

    Science.gov (United States)

    Newman, Lauri

    2015-01-01

    Single-obs tracking Sparsely tracked objects are an unfortunate reality of CARA operations Terra vs. 32081: new track with bad data was included in OD solution for secondary object and risk became high CARA and JSpOC discussed tracking and OSAs threw out the bad data. Event no longer presented high risk based on new OD Improvement: CARA now sends JSpOC a flag indicating when a single obs is included, so OSAs can evaluate if manual update to OD is required. Missing ASW OCMsAura vs. 87178, TCA: 317 at 08:04 UTC. Post-maneuver risk (conjunction was identified in OO results)CARA confirmed with JSpOC that ASW OCMs should have been received in addition to OO OCMsJSpOC corrected the manual error in their script that prevented the data from being delivered to CARAJSpOC QAd their other scripts to ensure this error did not exist in other places.

  10. HIRDLS/Aura Level 3 Extinction at 12.1 Microns Zonal Fourier Coefficients V007

    Data.gov (United States)

    National Aeronautics and Space Administration — The "HIRDLS/Aura Level 3 Extinction at 12.1 Microns Zonal Fourier Coefficients" version 7 data product (H3ZFC12MEXT) contains the entire mission (~3 years) of HIRDLS...

  11. MLS/Aura L2 Hydrogen Chloride (HCl) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydrogen chloride derived from radiances measured primarily by the 640 GHz radiometer. The...

  12. MLS/Aura L2 Hydrogen Cyanide (HCN) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HCN is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydrogen cyanide derived from radiances measured primarily by the 190 GHz radiometer. The...

  13. MLS/Aura L2 Hydrogen Cyanide (HCN) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HCN is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydrogen cyanide derived from radiances measured primarily by the 190 GHz radiometer. The...

  14. MLS/Aura Level 2 Hydrogen Chloride (HCl) Mixing Ratio V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydrogen chloride derived from radiances measured primarily by the 640 GHz radiometer. The...

  15. EOS Aura Mission Status at Earth Science Constellation MOWG Meeting @ LASP (Boulder, CO) April 13, 2016

    Science.gov (United States)

    Guit, William J.; Fisher, Dominic

    2016-01-01

    Presentation reflects EOS Aura mission status, spacecraft subsystems summary, recent and planned activities, inclination adjust maneuvers, propellant usage, orbit maintenance maneuvers, conjunction assessment events, orbital parameters trends and predictions.

  16. MLS/Aura L2 Chlorine Monoxide (ClO) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2CLO is the EOS Aura Microwave Limb Sounder (MLS) standard product for chlorine monoxide derived from radiances measured primarily by the 640 GHz radiometer. The...

  17. MLS/Aura Level 2 Diagnostics, Geophysical Parameter Grid V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2DGG is the EOS Aura Microwave Limb Sounder (MLS) product containing geophysical diagnostic quantities pertaining directly to the standard geophysical data...

  18. TES/Aura L3 H2O Monthly Gridded V004

    Data.gov (United States)

    National Aeronautics and Space Administration — The TES Aura L3 H2O data consist of daily atmospheric temperature and VMR for the atmospheric species. Data are provided at 2 degree latitude X 4 degree longitude...

  19. MLS/Aura L2 Nitric Acid (HNO3) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  20. MLS/Aura Level 2 Nitric Acid (HNO3) Mixing Ratio V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  1. MLS/Aura L2 Nitric Acid (HNO3) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  2. MLS/Aura Level 2 Hypochlorous Acid (HOCl) Mixing Ratio V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HOCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hypochlorous acid derived from radiances measured primarily by the 640 GHz radiometer. The...

  3. MLS/Aura L2 Hypochlorous Acid (HOCL) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HOCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hypochlorous acid derived from radiances measured primarily by the 640 GHz radiometer. The...

  4. MLS/Aura L2 Hypochlorous Acid (HOCL) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HOCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hypochlorous acid derived from radiances measured primarily by the 640 GHz radiometer. The...

  5. MLS/Aura L2 Hydroxyl (OH) Mixing Ratio V002

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2OH is the EOS Aura Microwave Limb Sounder (MLS) standard product for hydroxyl derived from radiances measured by the THz radiometer. The current version is 2.2....

  6. MLS/Aura Level 2 Nitrous Oxide (N2O) Mixing Ratio V004

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2N2O is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitrous oxide derived from radiances measured primarily by the 640 GHz radiometer (Band 12)...

  7. Numerical study of the stopping of aura during migraine

    Directory of Open Access Journals (Sweden)

    Moussa A.

    2010-12-01

    Full Text Available This work is devoted to the study of migraine with aura in the human brain. Following [6], we class migraine as a propagation of a wave of depolarization through the cells. The mathematical model used, based on a reaction-diffusion equation, is briefly presented. The equation is considered in a duct containing a bend, in order to model one of the numerous circumvolutions of the brain. For a wide set of parameters, one can establish the existence of a critical radius below which the wave stops. The approximation scheme used for the simulations is first described and then a numerical study is realized, precising the dependence of the critical radius with respect to the different parameters of the model. Ce travail est consacré à l’étude de l’évolution d’une migraine avec aura dans le cerveau humain. Suivant [6], nous assimilons la migraine à une onde de dépolarisation attaquant les cellules du cerveau. Le modèle mathématique retenu, basé sur une équation de réaction-diffusion, est brièvement rappelé. Le domaine d’espace utilisé est constitué d’un conduit présentant un coude, afin de représenter l’une des nombreuses circonvolutions cérébrales. Pour une importante classe de paramètres, il est possible de mettre en évidence l’existence d’un rayon critique au delà duquel le front d’onde n’arrive pas à dépasser le coude. Après une description du schéma d’approximation utilisé, une étude numérique a été réalisée, visant à préciser la dépendance du rayon critique en fonction des différents paramètres du modèle.

  8. Abnormal functional integration across core brain networks in migraine without aura.

    Science.gov (United States)

    Yu, Dahua; Yuan, Kai; Luo, Lin; Zhai, Jinquan; Bi, Yanzhi; Xue, Ting; Ren, Xiaoying; Zhang, Ming; Ren, Guoyin; Lu, Xiaoqi

    2017-01-01

    As a complex subjective experience, pain processing may be related to functional integration among intrinsic connectivity networks of migraine patients without aura. However, few study focused on the pattern alterations in the intrinsic connectivity networks of migraine patients without aura. Thirty-one migraine patients without aura and 31 age- and education-matched healthy controls participated in this study. After identifying the default mode network, central executive network and salience network as core intrinsic connectivity networks by using independent component analysis, functional connectivity, and effective connectivity during the resting state were used to investigate the abnormalities in intrinsic connectivity network interactions. Migraine patients without aura showed decreased functional connectivity among intrinsic connectivity networks compared with healthy controls. The strength of causal influences from the right frontoinsular cortex to the right anterior cingulate cortex became weaker, and the right frontoinsular cortex to the right medial prefrontal cortex became stronger in migraine patients without aura. These changes suggested that the salience network may play a major role in the pathophysiological features of migraine patients without aura and helped us to synthesize previous findings into an aberrant network dynamical framework.

  9. AURA-A radio frequency extension to IceCube

    International Nuclear Information System (INIS)

    Landsman, H.; Ruckman, L.; Varner, G.S.

    2009-01-01

    The excellent radio frequency (RF) transparency of cold polar ice, combined with the coherent Cherenkov emission produced by neutrino-induced showers when viewed at wavelengths longer than a few centimeters, has spurred considerable interest in a large-scale radio-wave neutrino detector array. The AURA (Askaryan Under-ice Radio Array) experimental effort, within the IceCube collaboration, seeks to take advantage of the opportunity presented by IceCube [A. Karle, Nucl. Instr. and Meth. A (2009), this issue, doi: (10.1016/j.nima.2009.03.180).; A. Achtenberg et al., The IceCube Collaboration, Astropart. Phys. 26 (2006) 155 ] drilling through 2010 to establish the RF technology needed to achieve 100-1000km 3 effective volumes. In the 2006-2007 Austral summer, three deep in-ice RF clusters were deployed at depths of ∼1300 and ∼300m on top of the IceCube strings. Additional three clusters will be deployed in the Austral summer of 2008-2009. Verification and calibration results from the current deployed clusters are presented, and the detector design and performances are discussed. Augmentation of IceCube with large-scale (1000km 3 sr) radio and acoustic arrays would extend the physics reach of IceCube into the EeV-ZeV regime and offer substantial technological redundancy.

  10. Observations of volcanic SO2 from MLS on Aura

    Directory of Open Access Journals (Sweden)

    H. C. Pumphrey

    2015-01-01

    Full Text Available Sulfur dioxide (SO2 is an important atmospheric constituent, particularly in the aftermath of volcanic eruptions. These events can inject large amounts of SO2 into the lower stratosphere, where it is oxidised to form sulfate aerosols; these in turn have a significant effect on the climate. The MLS instrument on the Aura satellite has observed the SO2 mixing ratio in the upper troposphere and lower stratosphere from August 2004 to the present, during which time a number of volcanic eruptions have significantly affected those regions of the atmosphere. We describe the MLS SO2 data and how various volcanic events appear in the data. As the MLS SO2 data are currently not validated we take some initial steps towards their validation. First we establish the level of internal consistency between the three spectral regions in which MLS is sensitive to SO2. We compare SO2 column values calculated from MLS data to total column values reported by the OMI instrument. The agreement is good (within about 1 DU in cases where the SO2 is clearly at altitudes above 147 hPa.

  11. Características clínicas da enxaqueca sem aura Clinical characteristics of migraine without aura

    Directory of Open Access Journals (Sweden)

    LUIZ PAULO DE QUEIROZ

    1998-03-01

    Full Text Available Um estudo aprofundado das características clínicas da enxaqueca sem aura (ESA revela alguns dados interessantes. Um questionário foi respondido por 200 pacientes que preenchiam os critérios da Sociedade Internacional de Cefaléia para ESA. O pico do início da enxaqueca foi entre 10 e 19 anos de idade. A cefaléia era restrita a um lado em 19%. Era exclusivamente bilateral em 9%. A maioria (86,2% dos pacientes que descreveram cefaléias em um único local localizou-a na área fronto-temporal. Cervicalgia estava associada aos ataques de enxaqueca em 70,5% e dor facial em 73,5%. O caráter latejante foi notado por 81%. Todos os pacientes descreveram a cefaléia como moderada a severa. Somente 55% disseram que a dor era agravada por atividades físicas rotineiras. Náusea ocorreu em 91%, foto e fonofobia em 77% e vômitos em 50%. Este olhar detalhado na ESA demonstra a grande complexidade dos seus sintomas.A detailed study of the clinical characteristics of migraine without aura (MOA reveals some interesting data. A questionnaire was returned by 200 patients who met the International Headache Society criteria for MOA. The peak of onset of migraine was between 10 and 19 years of age. The headache was side-locked in 19%. It was exclusively bilateral in 9%. The majority (86.2% of the patients who described headaches in only one site located them in the fronto-temporal area. Neck pain was associated with migraine attacks in 70.5% and face pain in 73.5%. A pounding quality was noted by 81%. Every patient described the headache as moderate to severe. Only 55% stated that it was aggravated by routine physical activity. Nausea occurred in 91%, photo and phonophobia in 77%, and vomiting in 50%. This close look at MOA uncovers a great complexity of symptoms.

  12. Effects of tonabersat on migraine with aura: a randomised, double-blind, placebo-controlled crossover study

    DEFF Research Database (Denmark)

    Hauge, Anne W; Asghar, Mohammed S; Schytz, Henrik W

    2009-01-01

    BACKGROUND: Migraine with aura is thought likely to be caused by cortical spreading depression (CSD). Tonabersat inhibits CSD, and we therefore investigated whether tonabersat has a preventive effect in migraine with aura. METHODS: In this randomised, double-blind, placebo-controlled crossover......, of whom 31 were included in the statistical analysis of efficacy. Median (IQR) attacks of aura were reduced from 3.2 (1.0-5.0) per 12 weeks on placebo to 1.0 (0-3.0) on tonabersat (p=0.01), whereas the other primary outcome measure, median migraine headache days with or without aura, was not significantly...... inhibitory effect on CSD. The results support the theory that auras are caused by CSD and that this phenomenon is not involved in attacks without aura. FUNDING: Minster Pharmaceuticals; Lundbeck Foundation....

  13. Tapio Aura - tsemenditehas tuleb järgmisele põlvkonnale üle anda natuke paremas seisus / Tapio Aura ; interv. Toomas Kään

    Index Scriptorium Estoniae

    Aura, Tapio

    2005-01-01

    AS Kunda Nordic Tsement juhatuse esimees on kümne Eestis elatud ja töötatud aastaga ära õppinud eesti keele ning teinud tehasest tugeva, jätkusuutliku ja konkurentsivõimelise ettevõtte. Lisa: Eino Tapio Aura. Kommenteerib maxit Estonia AS tegevdirektor Viktor Valkiainen

  14. Attachment styles in children affected by migraine without aura

    Directory of Open Access Journals (Sweden)

    Esposito M

    2013-10-01

    Full Text Available Maria Esposito,1 Lucia Parisi,2 Beatrice Gallai,3 Rosa Marotta,4 Anna Di Dona,1 Serena Marianna Lavano,2 Michele Roccella,4 Marco Carotenuto11Center for Childhood Headache, Clinic of Child and Adolescent Neuropsychiatry, Department of Mental Health, Physical and Preventive Medicine, Second University of Naples, Naples, Italy; 2Child Neuropsychiatry, Department of Psychology, University of Palermo, Palermo, Italy; 3Unit of Child and Adolescent Neuropsychiatry, University of Perugia, Perugia, Italy; 4Department of Psychiatry, The Magna Graecia University of Catanzaro, Catanzaro, ItalyBackground: In recent years, great attention has been given to the presence of psychological problems and psychiatric comorbidity that are also present in children affected by primary headaches. The relationship between pain and attachment has been identified, and it may be that pain perception may change in relation with specific attachment styles. The aim of the present study was to assess the prevalent attachment style and verify its putative relationship and correlation with the main characteristics of migraine attacks, in school-aged children affected by migraine without aura (MoA.Materials and methods: The study population consisted of 219 children (103 males, 116 females aged between 6 and 11 years (mean 8.96 ± 2.14 years, consecutively referred for MoA compared with 381 healthy controls (174 males, 207 females; mean age 9.01 ± 1.75 years randomly selected from schools. All the children were classified according to the attachment typologies of the Italian modified version of the Separation Anxiety Test; monthly headache frequency and mean headache duration were assessed from daily headache diaries kept by all the children. Headache intensity was assessed on a visual analogue scale. The chi-square test and t-test, where appropriate, were applied, and the Spearman rank correlation test was applied to explore the relationship between the types of attachment

  15. Heart rate variability in sleep-related migraine without aura.

    Science.gov (United States)

    Vollono, Catello; Gnoni, Valentina; Testani, Elisa; Dittoni, Serena; Losurdo, Anna; Colicchio, Salvatore; Di Blasi, Chiara; Mazza, Salvatore; Farina, Benedetto; Della Marca, Giacomo

    2013-07-15

    This is an observational study aimed to investigate the activity of autonomic nervous system during sleep in patients with sleep-related migraine. Eight consecutive migraineurs without aura were enrolled (6 women and 2 men), aged 30 to 62 years (mean 48.1 ± 9.3 years). Inclusion criteria were: high frequency of attacks (> 5 per month) and occurrence of more than 75% of the attacks during sleep causing an awakening. Patients were compared with a control group of 55 healthy subjects (23 men and 32 women, mean age 54.2 ± 13.0 years), and with a further control group of 8 age- and gender-matched healthy controls. Patient and controls underwent polysomnography and heart rate variability analysis. A significant reduction of the LF/HF ratio during N2 and N3 sleep stages was observed in migraineurs compared with controls. No differences in sleep macrostructure were observed; cyclic alternating pattern (CAP) time and CAP rate were lower in migraineurs than in controls. These findings indicate a peculiar modification of the autonomic balance during sleep in sleep-related migraine. The reduction of LF/HF ratio in NREM sleep was observed in controls, but it was quantitatively much more evident in migraineurs. Changes in LF/HF could be consequent to an autonomic unbalance which could manifest selectively (or alternatively become more evident) during sleep. These findings, together with the reduction in CAP rate, could be an expression of reduced arousability during sleep in patients with sleep-related migraine. The simultaneous involvement of the autonomic, arousal, and pain systems might suggest involvement of the hypothalamic pathways.

  16. [Cryptogenic stroke - patent foramen ovale - migraine with aura: incidental triad or significant relationship? Part II].

    Science.gov (United States)

    Łukasik, Maria; Kozubski, Wojciech

    2012-01-01

    In the second part of the paper, we discuss the relationship between migraine with aura and either patent foramen ovale (PFO) or stroke. The results of the studies suggest that PFO with right-to-left shunt is more prevalent among patients suffering from migraine with aura. Moreover, migraine with aura is a risk factor for ischaemic stroke in women and the risk increases when they have additional vascular risk factors such as taking oral contraception and smoking. However, the pathophysiology of these phenomena remains hypothetical. The most frequently reported theory suggests paradoxical embolism as a mechanism of the above-mentioned pathologies. In this paper we compare the pros and cons of the general theories. We discuss the percutaneous closure of PFO in patients with migraine, regarding the benefit/risk ratio.

  17. Increased intrinsic brain connectivity between pons and somatosensory cortex during attacks of migraine with aura

    DEFF Research Database (Denmark)

    Hougaard, Anders; Amin, Faisal Mohammad; Larsson, Henrik B W

    2017-01-01

    The neurological disturbances of migraine aura are caused by transient cortical dysfunction due to waves of spreading depolarization that disrupt neuronal signaling. The effects of these cortical events on intrinsic brain connectivity during attacks of migraine aura have not previously been......-based approach focusing on cortical visual areas and areas involved in migraine pain, and a data-driven independent component analysis approach to detect changes in intrinsic brain signaling during attacks. In addition, we performed the analyses after mirroring the MRI data according to the side of perceived......-sided pain. For aura-side normalized data, we found increased connectivity during attacks between visual area V5 and the lower middle frontal gyrus in the symptomatic hemisphere (peak voxel: P = 0.0194, (x, y, z) = (40, 40, 12). The present study provides evidence of altered intrinsic brain connectivity...

  18. Migraine aura: retracting particle-like waves in weakly susceptible cortex.

    Directory of Open Access Journals (Sweden)

    Markus A Dahlem

    Full Text Available Cortical spreading depression (SD has been suggested to underlie migraine aura. Despite a precise match in speed, the spatio-temporal patterns of SD observed in animal cortex and aura symptoms mapped to the cortical surface ordinarily differ in aspects of size and shape. We show that this mismatch is reconciled by utilizing that both pattern types bifurcate from an instability point of generic reaction-diffusion models. To classify these spatio-temporal pattern we suggest a susceptibility scale having the value sigma = 1 at the instability point. We predict that human cortex is only weakly susceptible to SD (sigma1, and potentially silent aura occurring below a second bifurcation point at sigma = 0 on the susceptible scale.

  19. History of migraine with aura and cortical spreading depression from 1941 and onwards

    DEFF Research Database (Denmark)

    Tfelt-Hansen, P C

    2010-01-01

    Several personal descriptions of migraine with aura from 1870 onwards reported a slow, gradual progression of symptoms. Lashley in 1941 meticulously chartered his own auras and concluded that the symptomatology reflected a cortical process progressing with a speed of 3 mm/min across the primary...... for measurements of regional cerebral blood flow (rCBF) in 1974 made it possible to detect spreading oligaemia during migraine aura. Between 1981 and 1990 a series of studies of rCBF during migraine attacks showed reduced brain blood flow posteriorly spreading slowly and contiguously anteriorly and crossing...... and it was considerably strengthened by the demonstration of a long-lasting oligaemia in rats in the wake of CSD. In the primates CSD is not easily elicited, but it has in recent years been clearly demonstrated in patients with brain trauma and stroke. Finally, mutations for familial hemiplegic migraine have been...

  20. OMI/Aura Ozone (O3) Profile 1-Orbit L2 Swath 13x48km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura Level-2 Ozone Profile data product OMO3PR (Version 003) is now available ( http://disc.gsfc.nasa.gov/Aura/OMI/omo3pr_v003.shtml ) from the NASA Goddard...

  1. OMI/Aura DOAS Total Column Ozone Zoomed 1-Orbit L2 Swath 13x12km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed OMI/Aura Level-2 Zoomed Ozone data product OMDOAO3Z at 13x12 km resolution is now available (http://disc.gsfc.nasa.gov/Aura/OMI/omdoao3z_v003.shtml )...

  2. Data processing and in-flight calibration systems for OMI-EOS-Aura

    Science.gov (United States)

    van den Oord, G. H. J.; Dobber, M.; van de Vegte, J.; van der Neut, I.; Som de Cerff, W.; Rozemeijer, N. C.; Schenkelaars, V.; ter Linden, M.

    2006-08-01

    The OMI instrument that flies on the EOS Aura mission was launched in July 2004. OMI is a UV-VIS imaging spectrometer that measures in the 270 - 500 nm wavelength range. OMI provides daily global coverage with high spatial resolution. Every orbit of 100 minutes OMI generates about 0.5 GB of Level 0 data and 1.2 GB of Level 1 data. About half of the Level 1 data consists of in-flight calibration measurements. These data rates make it necessary to automate the process of in-flight calibration. For that purpose two facilities have been developed at KNMI in the Netherlands: the OMI Dutch Processing System (ODPS) and the Trend Monitoring and In-flight Calibration Facility (TMCF). A description of these systems is provided with emphasis on the use for radiometric, spectral and detector calibration and characterization. With the advance of detector technology and the need for higher spatial resolution, data rates will become even higher for future missions. To make effective use of automated systems like the TMCF, it is of paramount importance to integrate the instrument operations concept, the information contained in the Level 1 (meta-)data products and the inflight calibration software and system databases. In this way a robust but also flexible end-to-end system can be developed that serves the needs of the calibration staff, the scientific data users and the processing staff. The way this has been implemented for OMI may serve as an example of a cost-effective and user friendly solution for future missions. The basic system requirements for in-flight calibration are discussed and examples are given how these requirements have been implemented for OMI. Special attention is paid to the aspect of supporting the Level 0 - 1 processing with timely and accurate calibration constants.

  3. Seasonal and spatial changes in trace gases over megacities from Aura TES observations: two case studies

    Directory of Open Access Journals (Sweden)

    K. E. Cady-Pereira

    2017-08-01

    Full Text Available The Aura Tropospheric Emission Spectrometer (TES is collecting closely spaced observations over 19 megacities. The objective is to obtain measurements that will lead to better understanding of the processes affecting air quality in and around these cities, and to better estimates of the seasonal and interannual variability. We explore the TES measurements of ozone, ammonia, methanol and formic acid collected around the Mexico City metropolitan area (MCMA and in the vicinity of Lagos (Nigeria. The TES data exhibit seasonal signals that are correlated with Atmospheric Infrared Sounder (AIRS CO and Moderate Resolution Imaging Spectroradiometer (MODIS aerosol optical depth (AOD, with in situ measurements in the MCMA and with Goddard Earth Observing System (GEOS-Chem model output in the Lagos area. TES was able to detect an extreme pollution event in the MCMA on 9 April 2013, which is also evident in the in situ data. TES data also show that biomass burning has a greater impact south of the city than in the caldera where Mexico City is located. TES measured enhanced values of the four species over the Gulf of Guinea south of Lagos. Since it observes many cities from the same platform with the same instrument and applies the same retrieval algorithms, TES data provide a very useful tool for easily comparing air quality measures of two or more cities. We compare the data from the MCMA and Lagos, and show that, while the MCMA has occasional extreme pollution events, Lagos consistently has higher levels of these trace gases.

  4. Self-concept evaluation and migraine without aura in childhood

    Directory of Open Access Journals (Sweden)

    Esposito M

    2013-08-01

    Full Text Available Maria Esposito,1 Beatrice Gallai,2 Lucia Parisi,3 Laura Castaldo,1 Rosa Marotta,4 Serena Marianna Lavano,4 Giovanni Mazzotta,5 Michele Roccella,3 Marco Carotenuto11Center for Childhood Headache, Clinic of Child and Adolescent Neuropsychiatry, Department of Mental Health, Physical and Preventive Medicine, Second University of Naples, Naples, Italy; 2Unit of Child and Adolescent Neuropsychiatry, University of Perugia, Perugia, Italy; 3Child Neuropsychiatry, Department of Psychology, University of Palermo, Palermo, Italy; 4Department of Psychiatry, "Magna Graecia" University of Catanzaro, Catanzaro, Italy; 5Unit of Child and Adolescent Neuropsychiatry, AUSL Umbria 2, Terni, ItalyIntroduction: Self-esteem is related to the broadly understood concept of self-schemas and is a crucial mechanism for a correct psychological development in children and adolescents. The impact of the many psychological difficulties linked to the migraine without aura (MoA and recurrent headache attacks, such as anger and separation anxiety, on self-esteem has not yet been well investigated. The aims of the present study were to assess self-esteem levels in an objective way and to verify their possible relationship and correlation with the frequency and intensity of migraine attacks, in a population of children and adolescents affected by MoA.Methods: The study population was comprised of 185 children (88 males [M], 97 females [F] aged between 6 and 12 years (mean 9.04 ± 2.41 years referred consecutively for MoA to the Center for Childhood Headache, Clinic of Child and Adolescent Neuropsychiatry, Second University of Naples and of 203 healthy controls (95 M, 108 F with mean age 9.16 ± 2.37 years, recruited from schools in Campania. The monthly headache frequency and the mean headache duration were assessed from daily headache diaries kept by all the children, and MoA intensity was assessed on a VAS (visual analog scale. To further evaluate their level of self-concept, all

  5. Timing and topography of cerebral blood flow, aura, and headache during migraine attacks

    DEFF Research Database (Denmark)

    Olesen, J; Friberg, L; Olsen, T S

    1990-01-01

    Ten years of study has resulted in considerable but fragmented knowledge about regional cerebral blood flow in migraine with aura (classic migraine). In the present study, the number of repeatedly studied patients (n = 63) was large enough to determine statistically significant sequences of event...

  6. Peri-ictal changes of cortical excitability in children suffering from migraine without aura

    DEFF Research Database (Denmark)

    Siniatchkin, Michael; Reich, Anna-Lena; Shepherd, Alex J

    2009-01-01

    aftereffect. Motor cortex excitability was not altered in patients and did not change during the migraine cycle. These findings show that pediatric migraine without aura is associated with a systematic shift in occipital excitability preceding the migraine attack. Similar systematic fluctuations in cortical...

  7. Assimilated ozone from EOS-Aura: Evaluation of the tropopause region and tropospheric columns

    NARCIS (Netherlands)

    Stajner, I.; Wargan, K.; Pawson, S.; Hayashi, H.; Chang, L.-P.; Hudman, R.C.; Froidevaux, L.; Livesey, N.J.; Levelt, P.F.; Thompson, A.M.; Tarasick, D.W.; Stübi, R.; Andersen, S.B.; Yela, M.; König-Langlo, G.; Schmidlin, F.J.; Witte, J.C.

    2008-01-01

    Retrievals from the Microwave Limb Sounder (MLS) and the Ozone Monitoring Instrument (OMI) on EOS-Aura were included in the Goddard Earth Observing System version 4 (GEOS-4) ozone data assimilation system. The distribution and daily to seasonal evolution of ozone in the stratosphere and troposphere

  8. Mission Status for Earth Science Constellation MOWG Meeting at KSC: EOS Aura

    Science.gov (United States)

    Fisher, Dominic

    2017-01-01

    This will be presented at the Earth Science Constellation Mission Operations Working Group (MOWG) meeting at KSC (Kennedy Space Center) in December 2017 to discus EOS (Earth Observing System) Aura status. Reviewed and approved by Eric Moyer, ESMO (Earth Sciences Mission Operations) Deputy Project Manager.

  9. Inimlik eksitus Lätis saatis kontrolli kõik Aura mahlajoogid / Hindrek Riikoja

    Index Scriptorium Estoniae

    Riikoja, Hindrek

    2006-01-01

    Tartu Õlletehase liiga suure säilitusaine sisalduse tõttu Lätis müügilt kõrvaldatud Aura Arcticu mahlajoogid tõid kaasa kogu tootesarja ulatusliku kontrolli. Rohkem eksimusi uuring ei tuvastanud. Lisa: Bensoehape

  10. Aura OMI observations of regional SO2 and NO2 pollution changes from 2005 to 2015

    NARCIS (Netherlands)

    Krotkov, Nickolay A.; McLinden, Chris A.; Li, Can; Lamsal, Lok N.; Celarier, Edward A.; Marchenko, Sergey V.; Swartz, William H.; Bucsela, Eric J.; Joiner, Joanna; Duncan, Bryan N.; Boersma, Folkert; Veefkind, J.P.; Levelt, Pieternel F.; Fioletov, Vitali E.; Dickerson, Russell R.; He, Hao; Lu, Zifeng; Streets, David G.

    2016-01-01

    The Ozone Monitoring Instrument (OMI) onboard NASA's Aura satellite has been providing global observations of the ozone layer and key atmospheric pollutant gases, such as nitrogen dioxide (NO2) and sulfur dioxide (SO2), since October 2004. The data products from the same instrument provide

  11. Addenbrooke's cognitive examination test for brief cognitive assessment of adolescents suffering from migraine with aura.

    Science.gov (United States)

    Petrusic, Igor; Pavlovski, Vera; Savkovic, Zorica; Vucinic, Dragana; Filipovic, Branislav; Jancic, Jasna

    2017-03-01

    The aim of this study was to assess the role of the Addenbrooke's cognitive examination test (ACE-R) in the evaluation of cognitive status in migraineurs interictally. A total of 44 adolescent patients and 44 healthy controls, matched by age and gender, have undergone ACE-R testing. Migraineurs were additionally questioned about migraine aura features and presence of higher cortical dysfunctions (HCD) during an aura. According to the questionnaire results, patients were subsequently divided into HCD and Non-HCD group. ACE-R scores of migraine patients were significantly lower than in healthy controls (93.68 ± 3.64 vs 96.91 ± 2.49; t = 4.852, p cognitive examination score, although Non-HCD subgroup achieved better score (93.13 ± 3.91 vs 94.29 ± 3.30; t = 1.053, p = 0.298). Findings have shown that migraineurs get lower ACE-R test scores, with a tendency to have a poorer outcome in more complex aura. Also, our study has revealed that the ACE-R test is an easily administered test for brief assessment of cognitive status in migraineurs. Future perspectives could be further evaluation of ACE-R test in larger sample size and the impact of migraine with aura on cognitive function in adolescents.

  12. Intact neurovascular coupling during executive function in migraine without aura: interictal near-infrared spectroscopy study

    DEFF Research Database (Denmark)

    Schytz, H W; Ciftçi, K; Akin, A

    2010-01-01

    An altered neurovascular coupling has been proposed in migraine. We aimed to investigate neurovascular coupling during a mental task interictally in patients with migraine without aura (MO) by near-infrared spectroscopy (NIRS). Twelve migraineurs and 12 healthy controls were included. Using NIRS,...

  13. Scent of aura? Clinical features of olfactory hallucinations during a migraine attack (OHM).

    Science.gov (United States)

    Mainardi, Federico; Rapoport, Alan; Zanchin, Giorgio; Maggioni, Ferdinando

    2017-02-01

    Introduction Olfactory hallucination during a migraine attack (OHM) is a rare phenomenon. At present, it is not considered a manifestation of migraine aura. Material and methods The clinical features of OHM were collected in 11 patients. Results Of the 11 patients, 10 had migraine without aura and one migraine with aura associated with OHM. Mean age at onset of headache and at appearance of OHM were respectively 17.8 and 32.3 years. Migraine average frequency was 3.9 attacks/month, 19% of them being associated with OHM. The temporal pattern of OHM maintained the same characteristics in the different attacks. OHM onset was described as sudden ( n = 5), gradual ( n = 3), initially sudden and then gradual ( n = 2), or developing in a few seconds ( n = 1). In most of the cases ( n = 8) OHM lasted from 3 to 10 minutes; it persisted during the pain phase (2-24 hours) in only three patients. The type of the perceived smell was invariably constant in nine patients. Conclusion OHM features fulfilled the ICHD-III beta criteria for typical aura.

  14. Migraine without aura is not associated with incomplete circle of Willis

    DEFF Research Database (Denmark)

    Ezzatian-Ahar, Shabnam; Amin, Faisal Mohammad; Obaid, Hayder Ghani

    2014-01-01

    the prevalence of incomplete circle of Willis in migraineurs and controls. In the present study we compared the prevalence of incomplete circle of Willis in female migraine patients without aura to female healthy non-migraine controls.Using 3-Tesla magnetic resonance angiography we recorded three...

  15. La "visión del aura" como experiencia alucinatoria en individuos no-clinicos The aura experience as cognitive perceptual schizotypy in non-clinical population

    Directory of Open Access Journals (Sweden)

    Alejandro Parra

    2008-12-01

    Full Text Available Individuos que dicen ver el aura/energía en forma espontánea también tienden a tener un nivel más elevado de actividad imaginativa/fantaseosa o de propensidad a la fantasía. Hay indicadores que muestran que quienes experimentan alta capacidad de absorción, usualmente experimentan también diversas formas parasomáticas, alucinaciones táctiles, y sensaciones de energías sutiles, asi como también ideación esquizotípica, error perceptual, y mayor sinestesia. El objetivo es correlacionar puntajes de absorción psicológica, disociación, propensidad a la fantasía, intensidad de la imaginería, y tendencia a la esquizotipia en individuos que dicen ver el aura (N=83 en comparación con un grupo sin experiencias (N=503. La muestra incluyó 678 estudiantes de psicología de ambos sexos, 449 (76,5% mujeres y 139 (23,5% varones, cuya rango etario es de 17 y 57 años (Media=25,54; SD=7,22 residentes en la Ciudad de Buenos Aires y alrededores. Ningun estudiante recibió compensación económica. Respecto a la experiencia de ver el aura, se formuló la pregunta de la siguiente manera: "¿Ha tenido alguna experiencia usted es capaz de ver campos de energia o luces alrededor del cuerpo de una persona? (si duda, por favor, responda no". Si la respuesta es afirmativa, la pregunta también mapea tres dimensiones de la experiencia: frecuencia de la experiencia, explicación subjetiva (racional, desconocida y paranormal de la experiencia, y positivo o negativo impacto (emocional en una escala Likert, siendo 1 positivo y 7 negativo. Los resultados muestran mayor nivel de esquizotipia cognitivo perceptual en comparación con quienes no tienen la experiencia. Posiblemente, estas personas tienen mucha más intensa vida imaginativa. Esta experiencia no necesariamente posee un significado psicopatológico para el individuo; quienes ven el aura simplemente podrían ser sensibles a las experiencias perceptuales anómalas.Individuals who claim being able to

  16. Avaliação da utilização do placebo nas crises agudas de migrânea sem aura, migrânea com aura e cefaléia do tipo tensional episódica Evaluation of placebo use in migraine without aura, migraine with aura and episodic tension-type headache acute attacks

    Directory of Open Access Journals (Sweden)

    Marcelo Eduardo Bigal

    2001-09-01

    Full Text Available O presente estudo apresenta a avaliação do efeito placebo no tratamento agudo da migrânea sem aura, migrânea com aura e cefaléia do tipo tensional episódica. Foram estudados pacientes que deram entrada entre 1 de março de 1997 a 31 de novembro de 1999 em dois pronto-socorros. Definiram-se três grupos, cada um com 30 pacientes: 1 - migrânea sem aura (MSA; 2 -- migrânea com aura (MCO; 3 -- cefaléia do tipo tensional episódica (CTTE. Os pacientes participavam de estudo randomizado para avaliar a eficácia de 4 drogas; aqueles randomizados para o placebo foram incluídos também. Os parâmetros avaliados foram: 1 -- dor; 2 - sintomas associados. Avaliados uma hora após a administração do placebo, 50% dos pacientes do grupo MSA, 23,3% dos pacientes do grupo MCA e 26,7% dos pacientes do grupo CTTE apresentavam melhora da dor. A melhora, avaliada pela escala numérica da dor foi, em média, de 41,6%, 23,1% e 36%, respectivamente. Houve também redução significativa de todos os sintomas associados. A utilização do placebo é, portanto, essencial na avaliação de drogas utilizadas no tratamento de cefaléias agudas.This study presents an evaluation of placebo response in the acute treatment of migraine with or without aura and episodic tension type headache. We studied patients admitted between March 1st,1997 and November 31st,1999 in two Emergency Room Units. Three groups had been defined, each one with 30 participants: migraine without aura (MWOA, migraine with aura (MWA and episodic tension-type headache (ETTH. Patients were participating of a randomized study to evaluate efficacy of 4 different drugs; those randomized to receive placebo were included. We evaluated pain and associated symptoms. After one hour of placebo administration, 50% of MWOA patients, 23.3% of MWA and 26.7% of ETTH had presented pain relief. The mean of this relief, evaluated by the numerical pain scale, was 41.6%, 23.1% and 36%, respectively. Use of placebo

  17. Right-to-left shunt may be prone to affect the white matter integrity of posterior circulation in migraine without aura.

    Science.gov (United States)

    Xie, Hui; Bian, Yitong; Jian, Zhijie; Huo, Kang; Liu, Rui; Zhu, Dan; Zhang, Lihui; Wu, Jun; Yang, Jian; Liu, Jixin; Luo, Guogang

    2018-01-01

    Numerous studies have indicated an association between migraine and right-to-left shunt. However, little is known about whether right-to-left shunt has an effect on the migraine brain. This observational study aims to explore the impact of right-to-left shunt on the brain of migraine without aura on microstructural level. Thirty-five patients with migraine without aura were enrolled in this study. Contrast-enhanced Transcranial Doppler was performed to evaluate the status of right-to-left shunt. Three-dimensional T1-weighted and diffusion tensor images were acquired for data analysis. We employed voxel-based morphometry and tract-based spatial statistical analyses to assess the differences of gray and white matter between migraineurs with and without right-to-left shunt, respectively. Among the 35 patients, 19 (54.3%) patients had right-to-left shunt. There were no significant differences in headache features between migraineurs with and without right-to-left shunt. There were significant increases of mean and radial diffusivity in migraineurs with right-to-left shunt compared with migraineurs without right-to-left shunt. The alterations were primarily located in the right posterior thalamic radiation, secondly in the body of corpus callosum and the right superior corona radiata. No significant differences were observed in values of fractional anisotropy and axial diffusivity. No significant between-group differences were found in gray matter volume. Right-to-left shunt may cause alterations of white matter integrity in migraine without aura, and the alterations are more likely to be located at the posterior circulation.

  18. Aura-biomes are present in the water layer above coral reef benthic macro-organisms

    Directory of Open Access Journals (Sweden)

    Kevin Walsh

    2017-08-01

    Full Text Available As coral reef habitats decline worldwide, some reefs are transitioning from coral- to algal-dominated benthos with the exact cause for this shift remaining elusive. Increases in the abundance of microbes in the water column has been correlated with an increase in coral disease and reduction in coral cover. Here we investigated how multiple reef organisms influence microbial communities in the surrounding water column. Our study consisted of a field assessment of microbial communities above replicate patches dominated by a single macro-organism. Metagenomes were constructed from 20 L of water above distinct macro-organisms, including (1 the coral Mussismilia braziliensis, (2 fleshy macroalgae (Stypopodium, Dictota and Canistrocarpus, (3 turf algae, and (4 the zoanthid Palythoa caribaeorum and were compared to the water microbes collected 3 m above the reef. Microbial genera and functional potential were annotated using MG-RAST and showed that the dominant benthic macro-organisms influence the taxa and functions of microbes in the water column surrounding them, developing a specific “aura-biome”. The coral aura-biome reflected the open water column, and was associated with Synechococcus and functions suggesting oligotrophic growth, while the fleshy macroalgae aura-biome was associated with Ruegeria, Pseudomonas, and microbial functions suggesting low oxygen conditions. The turf algae aura-biome was associated with Vibrio, Flavobacterium, and functions suggesting pathogenic activity, while zoanthids were associated with Alteromonas and functions suggesting a stressful environment. Because each benthic organism has a distinct aura-biome, a change in benthic cover will change the microbial community of the water, which may lead to either the stimulation or suppression of the recruitment of benthic organisms.

  19. Aura-biomes are present in the water layer above coral reef benthic macro-organisms.

    Science.gov (United States)

    Walsh, Kevin; Haggerty, J Matthew; Doane, Michael P; Hansen, John J; Morris, Megan M; Moreira, Ana Paula B; de Oliveira, Louisi; Leomil, Luciana; Garcia, Gizele D; Thompson, Fabiano; Dinsdale, Elizabeth A

    2017-01-01

    As coral reef habitats decline worldwide, some reefs are transitioning from coral- to algal-dominated benthos with the exact cause for this shift remaining elusive. Increases in the abundance of microbes in the water column has been correlated with an increase in coral disease and reduction in coral cover. Here we investigated how multiple reef organisms influence microbial communities in the surrounding water column. Our study consisted of a field assessment of microbial communities above replicate patches dominated by a single macro-organism. Metagenomes were constructed from 20 L of water above distinct macro-organisms, including (1) the coral Mussismilia braziliensis , (2) fleshy macroalgae ( Stypopodium , Dictota and Canistrocarpus ), (3) turf algae, and (4) the zoanthid Palythoa caribaeorum and were compared to the water microbes collected 3 m above the reef. Microbial genera and functional potential were annotated using MG-RAST and showed that the dominant benthic macro-organisms influence the taxa and functions of microbes in the water column surrounding them, developing a specific "aura-biome". The coral aura-biome reflected the open water column, and was associated with Synechococcus and functions suggesting oligotrophic growth, while the fleshy macroalgae aura-biome was associated with Ruegeria , Pseudomonas, and microbial functions suggesting low oxygen conditions. The turf algae aura-biome was associated with Vibrio, Flavobacterium, and functions suggesting pathogenic activity, while zoanthids were associated with Alteromonas and functions suggesting a stressful environment. Because each benthic organism has a distinct aura-biome, a change in benthic cover will change the microbial community of the water, which may lead to either the stimulation or suppression of the recruitment of benthic organisms.

  20. Auras in temporal lobe epilepsy with hippocampal sclerosis: relation to seizure focus laterality and post surgical outcome.

    Science.gov (United States)

    Ferrari-Marinho, Taíssa; Caboclo, Luís Otávio S F; Marinho, Murilo M; Centeno, Ricardo S; Neves, Rafael S C; Santana, Maria Teresa C G; Brito, Fernanda S; Junior, Henrique Carrete; Yacubian, Elza Márcia T

    2012-05-01

    We examined the relationship between presence and frequency of different types of auras and side of lesion and post surgical outcomes in 205 patients with medically intractable mesial temporal lobe epilepsy (MTLE) with unilateral hippocampal sclerosis (HS). With respect to the number of auras, multiple auras were not associated with side of lesion (p=0.551). The side of HS was not associated with the type of auras reported. One hundred fifty-seven patients were operated. The occurrence of multiple auras was not associated with post-surgical outcome (p=0.740). The presence of extratemporal auras was significantly higher in patients with poor outcome. In conclusion, this study suggests that the presence of extratemporal auras in patients with MTLE-HS possibly reflects extratemporal epileptogenicity in these patients, who otherwise showed features suggestive of TLE. Therefore, TLE-HS patients undergoing pre-surgical evaluation and presenting clinical symptoms suggestive of extratemporal involvement should be more extensively evaluated to avoid incomplete resection of the epileptogenic zone. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Potential source of cerebral embolism in migraine with aura: a transcranial Doppler study.

    Science.gov (United States)

    Anzola, G P; Magoni, M; Guindani, M; Rozzini, L; Dalla Volta, G

    1999-05-12

    The recently found association between patent foramen ovale (PFO) and transient global amnesia (TGA) has suggested that paradoxical microembolization in the terminal vertebrobasilar territory might underlie at least some TGA cases. Migraine with visual aura is another paroxysmal disturbance in which a sudden dysfunction of cortical areas fed by the terminal branches of the basilar artery is believed to trigger the attack. Therefore we investigated the prevalence of PFO in a consecutive unselected cohort of migraine patients. To investigate the prevalence of PFO in a consecutive unselected cohort of migraine patients to search for a possible mechanism for the reported association of migraine with stroke. A total of 113 patients, consecutively referred by the Headache Outpatient Clinic for migraine with aura (MA+, mean age 34+/-12 years) were compared with 53 patients with migraine without aura (MA-, mean age 36+/-13 years) and with 25 age-matched nonmigraine subjects (mean age 31+/-10 years) selected from the hospital staff. PFO was assessed with transcranial Doppler sonography with IV injection of agitated saline, a technique that is 90% sensitive and 100% specific. The prevalence of PFO was 48% (54/113) in MA+ patients, 23% (12/53) in MA- patients, and 20% (5/25) in control subjects. The difference between MA+ and MA- patients was significant (odds ratio [OR] = 3.13, 95% confidence interval [CI] = 1.41 to 7.04, chi2 = 9.52,p = 0.002) as was the difference between MA+ patients and controls (OR = 3.66, 95% CI = 1.21 to 13.25, chi2 = 6.46, p = 0.01), whereas MA- patients did not differ from controls (OR = 1.17, 95% CI = 0.32 to 4.45, chi2 = 0.07). MRI was negative in 22 MA+ and 8 MA- patients. Patency of the foramen ovale is associated with migraine with aura but not with migraine without aura. The increased risk of stroke found in epidemiologic studies in patients with migraine with aura may be explained by an increased propensity to paradoxical cerebral embolism.

  2. Five Blind Men and an Elephant: Comparing Aura Ozone Datasets and Sonde with Model Simulations

    Science.gov (United States)

    Tang, Q.; Prather, M. J.

    2011-12-01

    The four Earth Observing System (EOS) Aura satellite ozone measurements (HIRDLS, MLS, OMI, and TES) as well as the coincident WOUDC sonde are the five ``blind men'' touching the ``elephant'' (ozone). They all measure ozone (O3) in the upper troposphere and lower stratosphere (UT/LS) region, providing the great opportunity to study how the tropospheric ozone is influenced by the stratospheric source, an important tropospheric ozone budget term with large uncertainties and discrepancies across different models and methods. Based upon the 2-D autocorrelation for the tropospheric column ozone anomalies of the OMI swaths, we show that the stratosphere-troposphere exchange (STE) processes occur on the scale of a few hundred kilometers. Applying the high resolution (1o±1o±40-layer±0.5 hr) atmospheric chemistry transport model (CTM) as a transfer standard, we compare the noncoincident Aura level 2 swath datasets with the exact matching simulations of each measurement to investigate the consistency of different instruments as well as evaluate the accuracy of modeled ozone. Different signs of the CTM biases against HIRDLS, MLS, and TES are found from tropics to northern hemisphere (NH) mid-latitudes in July 2005 at 215 hPa and over tropics at 147 hPa for July 2005 and January 2006, suggesting inconsistency across these Aura datasets. On the other hand, the CTM has great positive biases against satellite observations in the lower stratosphere of winter time southern hemisphere (SH) mid-latitudes, which is probably attributed to the problems in the stratospheric circulation of the driving met-fields. The model's ability of reproducing STE-related processes, such as tropospheric folds (TFs), is confirmed by the comparisons with WOUDC sonde. We found eight cases in year 2005 with all the four Aura measurements available and folding structures in the coincident sonde profile. The case studies indicate that all the four Aura instruments demonstrate some skills in catching the

  3. OMI/Aura Sulphur Dioxide (SO2) Total Column 1-orbit L2 Swath 13x24 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Ozone Monitoring Instrument (OMI) was launched aboard the EOS-Aura satellite on July 15, 2004 (1:38 pm equator crossing time, ascending mode). OMI with its 2600...

  4. OMI/Aura Cloud Pressure and Fraction (Raman Scattering) 1-Orbit L2 Swath 13x24 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed Aura OMI Version 003 Level 2 Cloud Data Product OMCLDRR is made available (in April 2012) to the public from the NASA Goddard Earth Sciences Data and...

  5. MLS/Aura Level 2 Nitric Acid (HNO3) Mixing Ratio V003 (ML2HNO3) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  6. MLS/Aura Level 2 Hypochlorous Acid (HOCl) Mixing Ratio V003 (ML2HOCL) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HOCL is the EOS Aura Microwave Limb Sounder (MLS) standard product for hypochlorous acid derived from radiances measured primarily by the 640 GHz radiometer. The...

  7. MLS/Aura Level 2 Nitric Acid (HNO3) Mixing Ratio V004 (ML2HNO3) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2HNO3 is the EOS Aura Microwave Limb Sounder (MLS) standard product for nitric acid derived from radiances measured by the 240 GHz radiometer at and below 10 hPa,...

  8. OMI/Aura Ozone (O3) Total Column 1-Orbit L2 Swath 13x24 km V003 NRT

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura Level-2 Total Column Ozone Data Product OMTO3 Near Real Time data is made available from the OMI SIPS NASA for the public access. The Ozone Monitoring...

  9. Auras and clinical features in temporal lobe epilepsy: a new approach on the basis of voxel-based morphometry.

    Science.gov (United States)

    Santana, Maria Teresa Castilho Garcia; Jackowski, Andrea Parolin; da Silva, Henrique Hattori; Caboclo, Luis Otávio Sales Ferreira; Centeno, Ricardo Silva; Bressan, Rodrigo A; Carrete, Henrique; Yacubian, Elza Márcia Targas

    2010-05-01

    MRI investigations in patients with temporal lobe epilepsy (TLE) with mesial temporal sclerosis (MTS) have demonstrated structural abnormalities extending beyond ipsilateral hippocampus which may be studied through voxel-based morphometry (VBM). We investigated brain morphology related to clinical features in patients with refractory TLE with MTS using VBM. One hundred patients with unilateral TLE with MTS (59 left) and 30 controls were enrolled. VBM5 was employed to analyze (1) hemispheric damage, (2) influence of initial precipitating injury (IPI): 23 patients with febrile seizures and 19 with status epilepticus, and (3) types of auras classified as: mesial, including psychic auras (19 patients); anterior mesio-lateral, as autonomic symptoms, specially epigastric auras (27 patients) and neocortical, which included auditory, vertiginous, somatosensory and visual auras (16 patients). (1) Left TLE patients presented more widespread gray matter volume (GMV) reductions affecting ipsilateral hippocampus, temporal neocortex, insula and also left uncus, precentral gyrus, thalamus, parietal lobule, cuneus and bilateral cingulum. (2) Febrile seizures group presented ipsilateral GMV reductions in hippocampus, neocortical temporal, frontal and occipital cortices, insula and cingulum. Status epilepticus group presented more widespread GMV reductions involving temporal and extratemporal lobes. (3) Patients with mesial auras showed significant ipsilateral GMV reductions in hippocampus and amygdala, particularly right TLE group, who presented greater extension of GMV reduction in the entorhinal cortex. Significant reductions in hippocampus, amygdala and insula were seen in patients with anterior mesio-lateral auras. This study evaluated a large number of TLE-MTS patients showing structural damage extending beyond hippocampus, and different types of IPI associated with the extension of brain damage. Subtypes of auras are related to different clusters of areas of GMV reductions in

  10. Field-testing of the ICHD-3 beta/proposed ICD-11 diagnostic criteria for migraine with aura

    DEFF Research Database (Denmark)

    Li, Dana; Christensen, Anne F; Olesen, Jes

    2015-01-01

    migraine (SHM) and 1.2.6 basilar-type migraine according to ICHD-2 in a cross-sectional study design. A database of 2464 patients with 1.1 migraine without aura and 1.2 migraine with non-hemiplegic aura and a database of 252 hemiplegic migraine patients (1.2.4 FHM or 1.2.5 SHM) was collected. We used SPSS...

  11. Honey From Maggots: Aura, Sacrifice, and the Human Universe in Charles Olson's "The Kingfishers"

    Science.gov (United States)

    Roethle, Christopher James

    In this thesis, I contend that some form of aura can be recovered from the ravages of technological reproduction described in Walter Benjamin's "The Work of Art in the Age of its Technological Reproducibility (Third Version)." Recovering this aura, however, may require adopting an aesthetic of immediacy through destruction and even wanton disposability (what Georges Bataille in his general economic theory calls "nonproductive expenditure") to ensure that, though routinely diluted and discarded, the split-second authenticity of a work remains, its radical ephemerality and formal irreproducibility opposing the enslaving, commodifying powers of the copy. The poetry and poetic theory of American poet Charles Olson, especially in his long poem "The Kingfishers" and his essays "Projective Verse" and "Human Universe," serves as an example of how an author might inscribe auratic energy along nonproductive, general economic lines.

  12. Maintaining Aura's Orbit Requirements While Performing Orbit Maintenance Maneuvers Containing an Orbit Normal Delta-V Component

    Science.gov (United States)

    Johnson, Megan R.; Petersen, Jeremy D.

    2014-01-01

    The Earth Observing System (EOS) Afternoon Constellation consists of five member missions (GCOM-W1, Aqua, CALIPSO, CloudSat, and Aura), each of which maintain a frozen, sun-synchronous orbit with a 16-day repeating ground track that follows the Worldwide Reference System-2 (WRS-2). Under nominal science operations for Aura, the propulsion system is oriented such that the resultant thrust vector is aligned 13.493 degrees away from the velocity vector along the yaw axis. When performing orbit maintenance maneuvers, the spacecraft performs a yaw slew to align the thrust vector in the appropriate direction. A new Drag Make Up (DMU) maneuver operations scheme has been implemented for Aura alleviating the need for the 13.493 degree yaw slew. The focus of this investigation is to assess the impact that no-slew DMU maneuver operations will have on Aura's Mean Local Time (MLT) which drives the required along track separation between Aura and the constellation members, as well as Aura's frozen orbit properties, eccentricity and argument of perigee. Seven maneuver strategies were analyzed to determine the best operational approach. A mirror pole strategy, with maneuvers alternating at the North and South poles, was implemented operationally to minimize impact to the MLT. Additional analysis determined that the mirror pole strategy could be further modified to include frozen orbit maneuvers and thus maintain both MLT and the frozen orbit properties under noslew operations.

  13. Exploring the visual hallucinations of migraine aura: the tacit contribution of illustration.

    Science.gov (United States)

    Schott, G D

    2007-06-01

    The visual aura of migraine is a subjective phenomenon, and what the migraineur experiences is necessarily inaccessible to others. Fortunately, however, the sufferer can occasionally reveal what is being seen by means of graphic representation, enabling an otherwise closed 'window' to be opened on the transiently dysfunctioning brain. This article explores the unique contribution that illustration has made to understanding mechanisms subserving the visual aura. The most revealing illustrations are those made by the very few scientists who have recorded and analysed the scotomas, and in particular the expanding fortification spectra, experienced during their migraine attacks. It is solely through illustrations such as these that the uniform nature of many of these hallucinations has been demonstrated. As a result, it follows that there is likely to be a similarly uniform repertoire of processes that generate the hallucinations in the occipital cortex. The precise form of the zigzags that comprise the fortification spectrum, their shimmering appearance, and in particular the speed of the peripheral spread, all of which are entirely dependent on graphic display for their elucidation, enable conclusions to be reached about a number of the underlying pathophysiological mechanisms, including the involvement of spreading cortical depression, that likely occur. Illustration has been pivotal too in revealing uncommon and sometimes curious, if not bizarre, visual hallucinations, the forms of which suggest that extrastriate and temporal lobe involvement contributes to migraine aura in some instances. Illustration can also be valuable in differential diagnosis, depicting other forms of visual hallucination which result from a variety of non-migrainous causes. Illustration, particularly when made during the attack, provides an unusual, little used but powerful tool which uniquely allows the sufferer's subjective visual experiences to inform objective analysis. In turn, this

  14. Migrainous aura as stroke-mimic: The role of perfusion-computed tomography.

    Science.gov (United States)

    Ridolfi, Mariana; Granato, Antonio; Polverino, Paola; Furlanis, Giovanni; Ukmar, Maja; Zorzenon, Irene; Manganotti, Paolo

    2018-03-01

    The acute-onset of migrainuos aura (MA) can be erroneously diagnosed in Emergency Department (ED) as acute stroke (AS) and it can be classified as "stroke mimic" (SM). Perfusion computer tomography (PCT) may be useful to improve detection of infarcts. The aim of the study was to investigate the role in ED of PCT in improving diagnosis of migrainous aura. Data were compared with the well-defined perfusion patterns in patients with acute ischemic stroke. A standardized Stroke Protocol was planned. The protocol consisted in centralizing in ED all the patients with acute-onset of neurological symptoms compatible with cerebrovascular disease and in performing a general and neurological examination, hematological tests, brain non-contrast computed tomography (NCCT), CT angiography (CTA) of the supra-aortic and intracranial arteries and cerebral PCT. Patients with diagnosis of definite or probable acute stroke were hospitalized in Stroke Unit (SU). A six-months retrospective analysis of all the patients included in the Stroke Protocol and discharged from ED or from SU with a diagnosis of migraine with aura was performed. 172 patients were included in the Stroke Protocol and 6 patients were enrolled. NCCT, CTA and PCT were performed after 60-90 min from symptoms onset and revealed normal perfusion. Intravenous thrombolysis was performed only in one patient. Patients with acute-onset of neurological symptoms, who have rapid progressive improvement of symptoms, normal neuroimaging, in particular PCT, and preceding episodes of migraine with aura, may be considered as suffering from MA. In these cases, even if thrombolysis is safe, clinicians may defer a prompt aggressive treatment. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Laser Safety and Hazard Analysis for the Trailer (B70) Based AURA Laser System

    International Nuclear Information System (INIS)

    AUGUSTONI, ARNOLD L.

    2003-01-01

    A laser safety and hazard analysis was performed for the AURA laser system based on the 2000 version of the American National Standards Institute's (ANSI) Standard Z136.1, for ''Safe Use of Lasers'' and the 2000 version of the ANSI Standard Z136.6, for ''Safe Use of Lasers Outdoors''. The trailer based AURA laser system is a mobile platform, which is used to perform laser interaction experiments and tests at various national test sites. The trailer (B70) based AURA laser system is generally operated on the United State Air Force Starfire Optical Range (SOR) at Kirtland Air Force Base (KAFB), New Mexico. The laser is used to perform laser interaction testing inside the laser trailer as well as outside the trailer at target sites located at various distances from the exit telescope. In order to protect personnel, who work inside the Nominal Hazard Zone (NHZ), from hazardous laser emission exposures it was necessary to determine the Maximum Permissible Exposure (MPE) for each laser wavelength (wavelength bands) and calculate the appropriate minimum Optical Density (OD min ) of the laser safety eyewear used by authorized personnel and the Nominal Ocular Hazard Distance (NOHD) to protect unauthorized personnel who may have violated the boundaries of the control area and enter into the laser's NHZ

  16. [Migraine without aura treated with balance acupuncture therapy:a randomized controlled trial].

    Science.gov (United States)

    Wang, Jinzhong; Qin, Xiaolan; Xie, Wenyuan; Wang, Wenyuan

    2017-08-12

    To assess the effect of balance acupuncture for migraine without aura. Blind evaluation was conducted. Forty patients with migraine without aura were randomized into an observation group and a control group, 19 cases in each one with 1 patient dropped out respectively. In the observation group, Toutongxue , the middle point was used in the hollow before the 1, 2 metatarsal combination, and in the control group, a sham point was applied in the hollow before the 3, 4 metatarsal combination. The manipulation in the two groups was the same. The treatment was given for 4 weeks, once a day, 5 times a week. The comprehensive score and visual analogue scale (VAS) were used before and after treatment, as well as 4 weeks after treatment. The comprehensive score and VAS score after treatment in the observation group decreased after treatment (both P 0.05). All the indices in the observation group after treatment and at follow-up were lower than those in the control group (all P 0.05). Balance acupuncture at Toutongxue achieves obvious effect for migraine without aura, which can relieve pain.

  17. Intact blood-brain barrier during spontaneous attacks of migraine without aura

    DEFF Research Database (Denmark)

    Amin, F M; Hougaard, A; Cramer, S P

    2017-01-01

    BACKGROUND AND PURPOSE: The integrity of the blood-brain barrier (BBB) has been questioned in migraine, but BBB permeability has never been investigated during spontaneous migraine attacks. In the present study, BBB permeability during spontaneous attacks of migraine without aura was investigated......, brain stem, posterior pons and whole brain. The paired samples t test was used to compare Ki (permeability) values between the attack and headache-free days. RESULTS: Nineteen patients completed the study. Median time from onset of migraine attack to scan was 6.5 h (range 4.0-15.5 h). No change...

  18. Aura y La señorita Christina: un diálogo posible

    Directory of Open Access Journals (Sweden)

    Mihaela Comsa

    2015-01-01

    Full Text Available Estudio intertextual de Aura , de Carlos Fuentes y La señorita Christina , de Mircea Eliade. Ambos textos se revelan como portadores de la capacidad de la literatura para condicionar la irrupción en nuestro mundo de otros espacios, tiempos y seres cuyas existencias no se sujetan, afortunadamente, a la prueba de la realidad fáctica, porque al ser pobladores de ‘frases imaginarias’, y por lo tanto, de ‘realidades imaginarias’, imponen su identidad autorreferencial.

  19. Análise da camada de fibras nervosas da retina em portadores de enxaqueca com aura Retinal nerve fiber layer measurements in patients with migraine with aura

    Directory of Open Access Journals (Sweden)

    Felipe Andrade Medeiros

    2001-10-01

    Full Text Available Objetivo: Avaliar as possíveis alterações na camada de fibras nervosas da retina (CFNR em pacientes com enxaqueca com aura, detectada por meio da polarimetria de varredura a laser. Métodos: Vinte pacientes com enxaqueca com aura e vinte indivíduos normais foram estudados. Os critérios de inclusão para os dois grupos compreenderam: idade de pelo menos 18 anos; ausência de história de doenças oculares, exceto erro refracional ou estrabismo; e ausência de história familiar de hipertensão ocular ou glaucoma. Foram excluídos pacientes com erro refracional maior que 5 DE e/ou 2 DC; acuidade visual corrigida menor que 20/40; pressão intra-ocular maior que 21 mmHg; discos ópticos anômalos ou com escavação maior que 0,5 ou assimetria de escavação maior que 0,2; ou com presença de doenças retinianas concomitantes. Os pacientes foram submetidos a exame de campo visual (Humphrey 30-2 e análise da CFNR com a polarimetria a laser (GDx - Nerve Fiber Analyzer. Um olho de cada paciente foi randomizado para análise estatística. Resultados: Nenhum dos pacientes do grupo controle apresentou defeitos de campo visual. Nove olhos (45% dos pacientes com enxaqueca tiveram anormalidades de campo visual além de 95% do intervalo de confiança do normal, como indicado pelos índices MD, CPSD ou GHT. Os valores de retardo no setor superior da CFNR dos pacientes com enxaqueca foram significativamente menor que no grupo controle (p=0,005. Não houve diferença significativa entre os valores de retardo dos dois grupos nas medidas globais e nos setores inferior, nasal e temporal. Conclusão: As medidas de retardo obtidas com a polarimetria a laser foram significativamente menores na porção superior da CFNR dos pacientes com enxaqueca com aura, sugerindo possível dano isquêmico às fibras nervosas, relacionadas à enxaqueca.Purpose: To evaluate the possible alterations of the retinal nerve fiber layer (RNFL, as detected by scanning laser polarimetry

  20. OMI/Aura Sulphur Dioxide (SO2) Total Column Daily L2 Global 0.125 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura Level-2G SO2 Data Product OMSO2G (Version 003) is now available http://disc.gsfc.nasa.gov/Aura/OMI/omso2g_v003.shtml ) from the NASA Goddard Earth...

  1. OMI/Aura Cloud Pressure and Fraction (O2-O2 Absorption) Zoomed 1-Orbit L2 Swath 13x12km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed OMI/Aura Level-2 zoomed cloud data product OMCLDO2Z at 13x12 km resolution is now available ( http://disc.gsfc.nasa.gov/Aura/OMI/omcldo2z_v003.shtml...

  2. OMI/Aura Level 1B VIS Zoom-in Geolocated Earthshine Radiances 1-orbit L2 Swath 13x12 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Level-1B (L1B) Radiance Product OML1BRVZ (Version-3) from the Aura-OMI is now available (http://disc.gsfc.nasa.gov/Aura/OMI/oml1brvz_v003.shtml) to public from...

  3. OMI/Aura Level 1B UV Global Geolocated Earthshine Radiances 1-orbit L2 Swath 13x24 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Level-1B (L1B) Radiance Product OML1BRUG (Version-3) from the Aura-OMI is now available to public (http://disc.gsfc.nasa.gov/Aura/OMI/oml1brug_v003.shtml) from...

  4. OMI/Aura Level 1B UV Zoom-in Geolocated Earthshine Radiances 1-orbit L2 Swath 13x12 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Level-1B (L1B) Radiance Product OML1BRUZ (Version-3) from the Aura-OMI is now available (http://disc.gsfc.nasa.gov/Aura/OMI/oml1bruz_v003.shtml) to public from...

  5. OMI/Aura Nitrogen Dioxide (NO2) Total and Tropospheric Column 1-orbit L2 Swath 13x24 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The second release of collection 3 OMI/Aura Level-2 NO2 data product OMNO2 is now available (http://disc.gsfc.nasa.gov/Aura/OMI/omno2_v003.shtml ) to public and...

  6. OMI/Aura Ozone (O3) DOAS Total Column Daily L2 Global 0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura Level-2G Total Column Ozone Data Product OMDOAO3G (Version 003) is now available ( http://disc.gsfc.nasa.gov/Aura/OMI/omdoao3g_v003.shtml ) from the...

  7. OMI/Aura Cloud Pressure and Fraction (O2-O2 Absorption) Daily L2 Global 0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed OMI/Aura Level-2G cloud data product OMCLDO2G, is now available (http://disc.gsfc.nasa.gov/Aura/OMI/omcldo2g_v003.shtml) from the NASA Goddard Earth...

  8. OMI/Aura Ozone (O3) Total Column Daily L2 Global 0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura Level-2G Total Column Ozone Data Product OMTO3G (Version 003) is made available ( http://disc.gsfc.nasa.gov/Aura/OMI/omto3g_v003.shtml ) from the NASA...

  9. Increased cerebrovascular pCO2 reactivity in migraine with aura--a transcranial Doppler study during hyperventilation

    DEFF Research Database (Denmark)

    Thomsen, L L; Iversen, Helle Klingenberg; Olesen, J

    1995-01-01

    cerebral artery was measured with transcranial Doppler. In each subject a pCO2 reactivity index (RI) was calculated as (delta Vmean/baseline Vmean)/delta pCO2. Interictally, patients with migraine with aura showed higher RI (p ANOVA and multiple range test) than controls, whereas migraineurs without......-nitroglycerin-provoked healthy controls (p > 0.05, ANOVA and multiple range test). The exaggerated response in migraine with aura might predispose for the characteristic changes in rCBF seen during attacks....

  10. Hearing voices: does it give your patient a headache? A case of auditory hallucinations as acoustic aura in migraine

    Directory of Open Access Journals (Sweden)

    Van der Feltz-Cornelis CM

    2012-03-01

    Full Text Available Christina M van der Feltz-Cornelis1–3, Henk Biemans1, Jan Timmer11Clinical Centre for Body, Mind and Health, GGz Breburg, Tilburg, The Netherlands; 2Faculty of Social and Behavioral Sciences, Tilburg University, Tilburg, The Netherlands; 3Trimbos Instituut, Utrecht, The NetherlandsObjective: Auditory hallucinations are generally considered to be a psychotic symptom. However, they do occur without other psychotic symptoms in a substantive number of cases in the general population and can cause a lot of individual distress because of the supposed association with schizophrenia. We describe a case of nonpsychotic auditory hallucinations occurring in the context of migraine.Method: Case report and literature review.Results: A 40-year-old man presented with imperative auditory hallucinations that caused depressive and anxiety symptoms. He reported migraine with visual aura as well which started at the same time as the auditory hallucinations. The auditory hallucinations occurred in the context of nocturnal migraine attacks, preceding them as aura. No psychotic disorder was present. After treatment of the migraine with propranolol 40 mg twice daily, explanation of the etiology of the hallucinations, and mirtazapine 45 mg daily, the migraine subsided and no further hallucinations occurred. The patient recovered.Discussion: Visual auras have been described in migraine and occur quite often. Auditory hallucinations as aura in migraine have been described in children without psychosis, but this is the first case describing auditory hallucinations without psychosis as aura in migraine in an adult. For description of this kind of hallucination, DSM-IV lacks an appropriate category.Conclusion: Psychiatrists should consider migraine with acoustic aura as a possible etiological factor in patients without further psychotic symptoms presenting with auditory hallucinations, and they should ask for headache symptoms when they take the history. Prognosis may be

  11. Allestimenti museali, mostre e aura dei materiali tra le due guerre nel pensiero di Amedeo Maiuri / Museum displays, exhibitions and aura of materials between WWI and the WWII in Amedeo Maiuri’s thinking

    Directory of Open Access Journals (Sweden)

    Gabriella Prisco

    2016-12-01

    use of images, archival documents and antique texts, particularly with regard to what is illustrated in the same Maiuri contributions dedicated to individual installations, but above all in the report prepared on the occasion of the Madrid Conference of 1934 dedicated to the museums. This study reveals a portrait of a Maiuri well informed on the latest trends on the subject, some of which – such as dual path dedicated one to the general public and the other to scholars, the reduction of the objects to be exhibited, the clearing of the walls – he applied consistently, within arrangements where you may catch an echo of the environment museums. In its participation in two major exhibitions (“Augustea della Romanità” and “Prima Mostra Triennale delle Terre Italiane d’Oltremare” where protagonist was the archeology, finally it seizes an attachment to the display of the original, which contrasts with the prevailing will of the era to abdicate to the aura of materials in favor of more free equipment, but also more bent to the needs of propaganda, up to confl ict with the very foundations of the archaeological discipline in which Maiuri was a distinguished representative.

  12. Grey zones in the diagnosis of adult migraine without aura based on the International Classification of Headache Disorders-III beta: exploring the covariates of possible migraine without aura.

    Science.gov (United States)

    Ozge, Aynur; Aydinlar, Elif; Tasdelen, Bahar

    2015-01-01

    Exploring clinical characteristics and migraine covariates may be useful in the diagnosis of migraine without aura. To evaluate the diagnostic value of the International Classification of Headache Disorders (ICHD)-III beta-based diagnosis of migraine without aura; to explore the covariates of possible migraine without aura using an analysis of grey zones in this area; and, finally, to make suggestions for the final version of the ICHD-III. A total of 1365 patients (mean [± SD] age 38.5±10.4 years, 82.8% female) diagnosed with migraine without aura according to the criteria of the ICHD-III beta were included in the present tertiary care-based retrospective study. Patients meeting all of the criteria of the ICHD-III beta were classified as having full migraine without aura, while those who did not meet one, two or ≥3 of the diagnostic criteria were classified as zones I, II and III, respectively. The diagnostic value of the clinical characteristics and covariates of migraine were determined. Full migraine without aura was evident in 25.7% of the migraineurs. A higher likelihood of zone I classification was shown for an attack lasting 4 h to 72 h (OR 1.560; P=0.002), with pulsating quality (OR 4.096; P<0.001), concomitant nausea⁄vomiting (OR 2.300; P<0.001) and photophobia⁄phonophobia (OR 4.865; P<0.001). The first-rank determinants for full migraine without aura were sleep irregularities (OR 1.596; P=0.005) and periodic vomiting (OR 1.464; P=0.026). However, even if not mentioned in ICHD-III beta, the authors determined that motion sickness, abdominal pain or infantile colic attacks in childhood, associated dizziness and osmophobia have important diagnostic value. In cases that do not fulfill all of the diagnostic criteria although they are largely consistent with the characteristics of migraine in clinical terms, the authors believe that a history of infantile colic; periodic vomiting (but not periodic vomiting syndrome); recurrent abdominal pain; the

  13. MLS/Aura Near-Real-Time L2 Nitrous Oxide (N2O) Mixing Ratio V003

    Data.gov (United States)

    National Aeronautics and Space Administration — ML2N2O_NRT is the EOS Aura Microwave Limb Sounder (MLS) Near-Real-Time (NRT) product for nitrous oxide (N2O). This product contains daily N2O profiles taken from the...

  14. Primary intracranial angiomatoid fibrous histiocytoma presenting with anaemia and migraine-like headaches and aura as early clinical features

    DEFF Research Database (Denmark)

    Hansen, Jakob Møller; Larsen, Vibeke Andrée; Scheie, David

    2015-01-01

    A 17-year-old female with migraine with aura complained of fatigue and was diagnosed with anemia. Three years later, changes in her headache pattern prompted hospital referral. Brain MRI showed a bi-lobed extra-axial intracerebral tumor encroaching both parieto-occipital regions. The resection...

  15. Statistical Analysis of Deflation in Covariance and Resultant Pc Values for AQUA, AURA and TERRA

    Science.gov (United States)

    Hasan, Syed O.

    2016-01-01

    This presentation will display statistical analysis performed for raw conjunction CDMs received for the EOS Aqua, Aura and Terra satellites within the period of February 2015 through July 2016. The analysis performed indicates a discernable deflation in covariance calculated at the JSpOC after the utilization of the dynamic drag consider parameter was implemented operationally in May 2015. As a result, the overall diminution in the conjunction plane intersection of the primary and secondary objects appears to be leading to reduced probability of collision (Pc) values for these conjunction events. This presentation also displays evidence for this theory with analysis of Pc trending plots using data calculated by the SpaceNav CRMS system.

  16. Summer planetary-scale oscillations: aura MLS temperature compared with ground-based radar wind

    Directory of Open Access Journals (Sweden)

    C. E. Meek

    2009-04-01

    Full Text Available The advent of satellite based sampling brings with it the opportunity to examine virtually any part of the globe. Aura MLS mesospheric temperature data are analysed in a wavelet format for easy identification of possible planetary waves (PW and aliases masquerading as PW. A calendar year, 2005, of eastward, stationary, and westward waves at a selected latitude is shown in separate panels for wave number range −3 to +3 for period range 8 h to 30 days (d. Such a wavelet analysis is made possible by Aura's continuous sampling at all latitudes 82° S–82° N. The data presentation is suitable for examination of years of data. However this paper focuses on the striking feature of a "dish-shaped" upper limit to periods near 2 d in mid-summer, with longer periods appearing towards spring and fall, a feature also commonly seen in radar winds. The most probable cause is suggested to be filtering by the summer jet at 70–80 km, the latter being available from ground based medium frequency radar (MFR. Classically, the phase velocity of a wave must be greater than that of the jet in order to propagate through it. As an attempt to directly relate satellite and ground based sampling, a PW event of period 8d and wave number 2, which appears to be the original rather than an alias, is compared with ground based radar wind data. An appendix discusses characteristics of satellite data aliases with regard to their periods and amplitudes.

  17. Comparison of Ambu® AuraGain™ laryngeal mask and air-Q™ intubating laryngeal airway for blind tracheal intubation in adults: A randomized controlled trial

    OpenAIRE

    Sameer Sethi; Souvik Maitra; Vikas Saini; Tanvir Samara

    2017-01-01

    Background: This study has been designed to compare the performance of Ambu® AuraGain™ laryngeal mask with the air-Q™ as a conduit for blind tracheal intubation in adult patients. Methods: In this prospective randomized controlled trial blind endotracheal intubation success rates were compared between Ambu® AuraGain™ and air-Q™ intubating laryngeal airway in 90 adult patients. Patients were randomized in two equal groups: Group Ambu® AuraGain™ (n = 45) and Group air-Q™ (n = 45). Results...

  18. OMI/Aura Sulfur Dioxide (SO2) Total Column Daily L3 Best Pixel Global 0.25deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura Level-3e SO2 Data Product OMSO2e (Version 003) is now available from the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) for...

  19. OMI/Aura Aerosol product Multi-wavelength Algorithm Zoomed 1-Orbit L2 Swath 13x12km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed OMI/Aura Level-2 Zoomed Aerosol data product OMAEROZ at 13x12 km resolution has been made available from the NASA Goddard Earth Sciences Data and...

  20. OMI/Aura Aerosol product Multi-wavelength Algorithm Zoomed 1-Orbit L2 Swath 13x12km V003 (OMAEROZ) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed OMI/Aura Level-2 Zoomed Aerosol data product OMAEROZ at 13x12 km resolution have been made available from the NASA Goddard Earth Sciences Data and...

  1. OMI/Aura Near UV Aerosol Optical Depth and Single Scattering Albedo Daily L3 Global 1x1 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI-Aura level-3 daily global gridded (1x1 deg) near-UV Aerosol data product OMAERUVd based on the enhanced algorithm is available from the NASA Goddard Earth...

  2. OMI/Aura Near UV Aerosol Optical Depth and Single Scattering Albedo 1-orbit L2 Swath 13x24 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura level-2 near UV Aerosol data product 'OMAERUV', recently re-processed using an enhanced algorithm, is now released (April 2012) to the public. The data...

  3. OMI/Aura Multi-wavelength Aerosol Optical Depth and Single Scattering Albedo 1-orbit L2 Swath 13x24 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The improved Level-2 OMI Aerosol Product 'OMAERO' is now available (http://disc.gsfc.nasa.gov/Aura/OMI/omaero_v003.shtml ) from NASA GSFC Earth Sciences (GES) Data...

  4. OMI/Aura Near UV Aerosol Optical Depth and Single Scattering Albedo 1-orbit L2 Swath 13x24 km V003 NRT

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura level-2 near UV Aerosol data product 'OMAERUV', recently re-processed using an enhanced algorithm, is now released (April 2012) to the public. The data...

  5. OMI/Aura Ozone(O3) Total Column 1-Orbit L2 Swath 13x24 km V003 (OMTO3) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The Aura Ozone Monitoring Instrument (OMI) Level-2 Total Column Ozone Data Product OMTO3 (Version 003) is available from the NASA Goddard Earth Sciences Data and...

  6. HIRDLS/Aura Level 3 Nitrogen Dioxide (NO2) 1deg Lat Zonal Fourier Coefficients V007 (H3ZFCNO2) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The "HIRDLS/Aura Level 3 Nitrogen Dioxide (NO2) Zonal Fourier Coefficients" version 7 data product (H3ZFCNO2) contains the entire mission (~3 years) of HIRDLS data...

  7. Fauna helmintológica peruana: Paryphostomum huaccaci sp. n. (Echinostomotidoe parásito de Cathartes aura jota Molino, 1782

    Directory of Open Access Journals (Sweden)

    Nicanor Ibáñez H.

    2014-06-01

    Full Text Available Es motivo de la presente nota, contribuir al conocimiento de un trematodo: Paryphostomum huaccaci sp. n. perteneciente o la Familia Echinostomatidae Poche, 1926 y que parásita a Cathartes aura jota Molina, 1782.

  8. OMI/Aura Surface UVB Irradiance and Erythemal Dose Daily L2 Global 0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Version 003 of Aura-OMI Spectral Surface UVB Irradiance and Erythemal Dose Level-2G data product (Daily level-2 data binned into global 0.25 deg Lat/Lon grids)...

  9. OMI/Aura Effective Cloud Pressure and Fraction (Raman Scattering) Daily L2 Global 0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed Version-3 Aura OMI Level-2G Cloud data product OMCLDRRG has been made available (in April 2012) to the public from the NASA Goddard Earth Sciences...

  10. OMI/Aura Cloud Pressure and Fraction (O2-O2 Absorption) 1-Orbit L2 Swath 13x24km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed OMI/Aura Level-2 cloud data product OMCLDO2 is now available from the NASA GoddardEarth Sciences Data and Information Services Center (GES DISC) for...

  11. OMI/Aura Effective Cloud Pressure and Fraction (Raman Scattering) 1-Orbit L2 Swath 13x24 km V003 (OMCLDRR) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed Aura Ozone Monitoring Instrument (OMI) Version 003 Level 2 Cloud Data Product OMCLDRR is available to the public from the NASA Goddard Earth Sciences...

  12. OMI/Aura Cloud Pressure and Fraction (O2-O2 Absorption) 1-Orbit L2 Swath 13x24km V003 (OMCLDO2) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The reprocessed OMI/Aura Level-2 cloud data product OMCLDO2 is now available from the NASA GoddardEarth Sciences Data and Information Services Center (GES DISC) for...

  13. OMI/Aura Surface UVB Irradiance and Erythemal Dose Daily L3 Global 1.0x1.0 deg Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Aura-OMI Daily Gridded Surface UV Irradiance Product (OMUVBd) is now available from the NASA Goddard Earth Sciences Data and Information Services Center (GES...

  14. OMI/Aura Global Ground Pixel Corners 1-Orbit L2 Swath 13x24km V003 (OMPIXCOR) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The Version-3 Aura Ozone Monitoring Instrument (OMI) Pixel Corner Product, OMPIXCOR, is now available from the NASA Goddard Earth Sciences Data and Information...

  15. OMI/Aura Zoom-in Ground Pixel Corners 1-Orbit L2 Swath 13x12km V003 (OMPIXCORZ) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The Version-3 Aura Ozone Monitoring Instrument (OMI) Pixel Corner Product in zoom-in mode, OMPIXCORZ, is now available from the NASA Goddard Earth Sciences Data and...

  16. OMI/Aura and MODIS/Aqua Merged Cloud Product 1-Orbit L2 Swath 13x24 km V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura and MODIS/Aqua Merged Cloud Product 1-Orbit L2 Swath 13x24 km (OMMYDCLD) is a Level-2 orbital product that combines cloud parameters retrieved by the...

  17. OMI/Aura and MODIS/Aqua Merged Cloud Product 1-Orbit L2 Swath 13x24 km V003 (OMMYDCLD) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura and MODIS/Aqua Merged Cloud Product 1-Orbit L2 Swath 13x24 km (OMMYDCLD) is a Level-2 orbital product that combines cloud parameters retrieved by the...

  18. OMI/Aura NO2 Total and Tropospheric Column Daily L2 Global 0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The second Release of Collection 003 of OMI/Aura Global Gridded Nitrogen Dioxide Product 'OMNO2G' is now available, from the NASA Goddard Earth Sciences Data and...

  19. OMI/Aura TOMS-Like Ozone and Radiative Cloud Fraction Daily L3 Global 0.25x0.25 deg V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Version-003 of Level-3 Aura/OMI daily global TOMS-Like Total Column Ozone gridded product (OMTO3e) is generated by the NASA OMI science team by picking the best...

  20. Interhemispheric differences of fMRI responses to visual stimuli in patients with side-fixed migraine aura

    DEFF Research Database (Denmark)

    Hougaard, Anders; Amin, Faisal Mohammad; Hoffmann, Michael B

    2014-01-01

    hemifield. We recruited 20 patients with frequent side-fixed visual aura attacks (≥90% of auras occurring in the same visual hemifield) and 20 age and sex matched healthy controls and compared the fMRI blood oxygenation level dependent (BOLD) responses to visual stimulation between symptomatic...... and asymptomatic hemispheres during the interictal phase and between migraine patients and controls. BOLD responses were selectively increased in the symptomatic hemispheres. This was found in the inferior parietal lobule (P = 0.002), the inferior frontal gyrus (P = 0.003), and the superior parietal lobule (P = 0.......017). The affected cortical areas comprise a visually driven functional network involved in oculomotor control, guidance of movement, motion perception, visual attention, and visual spatial memory. The patients also had significantly increased response in the same cortical areas when compared to controls (P

  1. Promoting Dark Sky Protection in Chile: the Gabriel Mistral IDA Dark Sky Sanctuary and Other AURA Initiatives

    Science.gov (United States)

    Smith, R. Chris; Smith, Malcolm; Pompea, Stephen; Sanhueza, Pedro; AURA-Chile EPO Team

    2018-01-01

    For over 20 years, AURA has been leading efforts promoting the protection of dark skies in northern Chile. Efforts began in the early 1990s at AURA's Cerro Tololo Inter-American Observatory (CTIO), working in collaboration with other international observatories in Chile including Las Campanas Observatory (LCO) and the European Southern Observatory (ESO). CTIO also partnered with local communities, for example supporting Vicuña's effort to establish the first municipal observatory in Chile. Today we have developed a multifaceted effort of dark sky protection, including proactive government relations at national and local levels, a strong educational and public outreach program, and a program of highlighting international recognition of the dark skies through the IDA Dark Sky Places program. Work on international recognition has included the declaration of the Gabriel Mistral IDA Dark Sky Sanctuary, the first such IDA sanctuary in the world.

  2. Effect of hypoxia on BOLD fMRI response and total cerebral blood flow in migraine with aura patients

    DEFF Research Database (Denmark)

    Arngrim, Nanna; Hougaard, Anders; Schytz, Henrik W

    2018-01-01

    was measured in the visual cortex ROIs V1-V5. Total cerebral blood flow (CBF) was calculated by measuring the blood velocity in the internal carotid arteries and the basilar artery using phase-contrast mapping (PCM) MRI. Hypoxia induced a greater decrease in BOLD response to visual stimulation in V1-V4 in MA......Experimentally induced hypoxia triggers migraine and aura attacks in patients suffering from migraine with aura (MA). We investigated the blood oxygenation level-dependent (BOLD) signal response to visual stimulation during hypoxia in MA patients and healthy volunteers. In a randomized double......-blind crossover study design, 15 MA patients were allocated to 180 min of normobaric poikilocapnic hypoxia (capillary oxygen saturation 70-75%) or sham (normoxia) on two separate days and 14 healthy volunteers were exposed to hypoxia. The BOLD functional MRI (fMRI) signal response to visual stimulation...

  3. Hypersomnia in children affected by migraine without aura: a questionnaire-based case-control study

    Directory of Open Access Journals (Sweden)

    Esposito M

    2013-02-01

    Full Text Available Maria Esposito,1 Michele Roccella,2 Lucia Parisi,2 Beatrice Gallai,3 Marco Carotenuto11Center for Childhood Headache, Unit of Child and Adolescent Neuropsychiatry, Department of Mental Health, Physical, and Preventive Medicine, Second University of Naples, Naples, Italy; 2Child Neuropsychiatry, Department of Psychology, University of Palermo, Palermo, Italy; 3Unit of Child and Adolescent Neuropsychiatry, University of Perugia, Perugia, ItalyBackground: The relationship between sleep and headache is meaningful and complex. Children affected by migraines tend to show many sleep disorders, such as insufficient sleep duration and excessive daytime somnolence. Therefore, the aim of this study is to assess the rate of reported sleep habits and self-reported sleepiness in a large pediatric sample of individuals affected by migraine without aura (MoA.Methods: The study population consisted of 271 children aged between 6 and 13 years affected by MoA. The control group was composed of 305 typically developing children. To assess the sleep habits of all individuals (MoA and control, parents filled out the Sleep Disturbance Scale for Children, and to check the degree of subjective perceived daytime sleepiness, all subjects were administered the Pediatric Daytime Sleepiness Scale.Results: The two study groups were matched for age (P = 0.124, sex distribution (P = 0.775, and body mass index z-score (P = 0.107. Parents of children affected by MoA reported a higher total score of sleep disorder symptoms (P < 0.001, disorders of initiating and maintaining (P < 0.001, and disorders of arousal (P < 0.001 than did parents of controls. No significant differences were found in disorders of excessive somnolence. Conversely, in the Pediatric Daytime Sleepiness Scale, migraine children had higher scores (24.67 ± 3.19 vs 11.94 ± 4.81; P < 0.001 and a reduction in referred total sleep time mean duration (469.83 ± 98.112 vs 527.94 ± 83.02; P < 0.001 than typically

  4. Updated SO2 emission estimates over China using OMI/Aura observations

    Science.gov (United States)

    Elissavet Koukouli, Maria; Theys, Nicolas; Ding, Jieying; Zyrichidou, Irene; Mijling, Bas; Balis, Dimitrios; van der A, Ronald Johannes

    2018-03-01

    The main aim of this paper is to update existing sulfur dioxide (SO2) emission inventories over China using modern inversion techniques, state-of-the-art chemistry transport modelling (CTM) and satellite observations of SO2. Within the framework of the EU Seventh Framework Programme (FP7) MarcoPolo (Monitoring and Assessment of Regional air quality in China using space Observations) project, a new SO2 emission inventory over China was calculated using the CHIMERE v2013b CTM simulations, 10 years of Ozone Monitoring Instrument (OMI)/Aura total SO2 columns and the pre-existing Multi-resolution Emission Inventory for China (MEIC v1.2). It is shown that including satellite observations in the calculations increases the current bottom-up MEIC inventory emissions for the entire domain studied (15-55° N, 102-132° E) from 26.30 to 32.60 Tg annum-1, with positive updates which are stronger in winter ( ˜ 36 % increase). New source areas were identified in the southwest (25-35° N, 100-110° E) as well as in the northeast (40-50° N, 120-130° E) of the domain studied as high SO2 levels were observed by OMI, resulting in increased emissions in the a posteriori inventory that do not appear in the original MEIC v1.2 dataset. Comparisons with the independent Emissions Database for Global Atmospheric Research, EDGAR v4.3.1, show a satisfying agreement since the EDGAR 2010 bottom-up database provides 33.30 Tg annum-1 of SO2 emissions. When studying the entire OMI/Aura time period (2005 to 2015), it was shown that the SO2 emissions remain nearly constant before the year 2010, with a drift of -0.51 ± 0.38 Tg annum-1, and show a statistically significant decline after the year 2010 of -1.64 ± 0.37 Tg annum-1 for the entire domain. Similar findings were obtained when focusing on the greater Beijing area (30-40° N, 110-120° E) with pre-2010 drifts of -0.17 ± 0.14 and post-2010 drifts of -0.47 ± 0.12 Tg annum-1. The new SO2 emission inventory is publicly available and forms

  5. Auditory aura in nocturnal frontal lobe epilepsy: a red flag to suspect an extra-frontal epileptogenic zone.

    Science.gov (United States)

    Ferri, Lorenzo; Bisulli, Francesca; Nobili, Lino; Tassi, Laura; Licchetta, Laura; Mostacci, Barbara; Stipa, Carlotta; Mainieri, Greta; Bernabè, Giorgia; Provini, Federica; Tinuper, Paolo

    2014-11-01

    To describe the anatomo-electro-clinical findings of patients with nocturnal hypermotor seizures (NHS) preceded by auditory symptoms, to evaluate the localizing value of auditory aura. Our database of 165 patients with nocturnal frontal lobe epilepsy (NFLE) diagnosis confirmed by videopolysomnography (VPSG) was reviewed, selecting those who reported an auditory aura as the initial ictal symptom in at least two NHS during their lifetime. Eleven patients were selected (seven males, four females). According to the anatomo-electro-clinical data, three groups were identified. Group 1 [defined epileptogenic zone (EZ)]: three subjects were studied with stereo-EEG. The EZ lay in the left superior temporal gyrus in two cases, whereas in the third case seizures arose from a dysplastic lesion located in the left temporal lobe. One of these three patients underwent left Heschl's gyrus resection, and is currently seizure-free. Group 2 (presumed EZ): three cases in which a presumed EZ was identified; in the left temporal lobe in two cases and in the left temporal lobe extending to the insula in one subject. Group 3 (uncertain EZ): five cases had anatomo-electro-clinical correlations discordant. This work suggests that auditory aura may be a helpful anamnestic feature suggesting an extra-frontal seizure origin. This finding could guide secondary investigations to improve diagnostic definition and selection of candidates for surgical treatment. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  6. A Global Climatology of Tropospheric and Stratospheric Ozone Derived from Aura OMI and MLS Measurements

    Science.gov (United States)

    Ziemke, J.R.; Chandra, S.; Labow, G.; Bhartia, P. K.; Froidevaux, L.; Witte, J. C.

    2011-01-01

    A global climatology of tropospheric and stratospheric column ozone is derived by combining six years of Aura Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS) ozone measurements for the period October 2004 through December 2010. The OMI/MLS tropospheric ozone climatology exhibits large temporal and spatial variability which includes ozone accumulation zones in the tropical south Atlantic year-round and in the subtropical Mediterranean! Asia region in summer months. High levels of tropospheric ozone in the northern hemisphere also persist in mid-latitudes over the eastern North American and Asian continents extending eastward over the Pacific Ocean. For stratospheric ozone climatology from MLS, largest ozone abundance lies in the northern hemisphere in the latitude range 70degN-80degN in February-April and in the southern hemisphere around 40degS-50degS during months August-October. The largest stratospheric ozone abundances in the northern hemisphere lie over North America and eastern Asia extending eastward across the Pacific Ocean and in the southern hemisphere south of Australia extending eastward across the dateline. With the advent of many newly developing 3D chemistry and transport models it is advantageous to have such a dataset for evaluating the performance of the models in relation to dynamical and photochemical processes controlling the ozone distributions in the troposphere and stratosphere.

  7. Orbitofrontal disinhibition of pain in migraine with aura: an interictal EEG-mapping study.

    Science.gov (United States)

    Lev, Rina; Granovsky, Yelena; Yarnitsky, David

    2010-08-01

    This study aimed to identify the cortical mechanisms underlying the processes of interictal dishabituation to experimental pain in subjects suffering from migraine with aura (MWA). In 21 subjects with MWA and 22 healthy controls, cortical responses to two successive trials of noxious contact-heat stimuli were analyzed using EEG-tomography software. When compared with controls, MWA patients showed significantly increased pain-evoked potential amplitudes accompanied by reduced activity in the orbitofrontal cortex (OFC) and increased activity in the pain matrix regions, including the primary somatosensory cortex (SI) (p < .05). Similarly to controls, MWA subjects displayed an inverse correlation between the OFC and SI activities, and positive interrelations between other pain-specific regions. The activity changes in the OFC negatively correlated with lifetime headache duration and longevity (p < .05). Reduced inhibitory functioning of the prefrontal cortex is a possible cause for disinhibition of the pain-related sensory cortices in migraine. The finding of OFC hypofunction over the disease course is in keeping with current concepts of migraine as a progressive brain disorder.

  8. Determination of uranium and polonium in Spa rus aura ta by alpha spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Luna P, M.; Renteria, M.; Montero C, M. E. [Centro de Investigacion en Materiales Avanzados, S. C., Miguel de Cervantes No. 120, Complejo Industrial Chihuahua, 31109 Chihuahua (Mexico); Manjon C, G.; Diaz, I., E-mail: elena.montero@cimav.edu.mx [Universidad de Sevilla, Escuela Tecnica Superior de Arquitectura, Departamento de Fisica Aplicada II, San Fernando No. 4, 41004 Sevilla (Spain)

    2012-06-15

    The aim of this study was optimizing conditions for the specific activities determination of some uranium-series radionuclides present in Spa rus aura ta by alpha spectrometry. Determinations of specific activities were conducted varying the type of digestion: acid attack on hot plate, controlled microwave digestion and acid attack after calcination of the sample. The latter procedure was applied only to the case of uranium isotopes determination. The variation in the isotope extraction method consisted of applying the techniques of liquid-liquid extracting using Tributyl phosphate or chromatographic UTEVA resin. Results depending on the type of treatment given to the samples were compared based on obtained chemical yields. The results reveal a higher bioaccumulation of polonium in the liver sample, with activities of 0.809, 2.495 and 2.439 Bq kg{sup -1} fresh wt compared with the fillet. The best chemical yields of polonium were close to 60% for samples that were digested by microwave. In the case of uranium the best chemical yields, close to 80% for fillet, were obtained with a previous calcination of the sample and using the UTEVA resin. (Author)

  9. Coexistencia del autor medieval y el autor contemporáneo en Aura

    Directory of Open Access Journals (Sweden)

    Maite Pizarro Granada

    2017-11-01

    Full Text Available Este artículo plantea para la novela Aura, una entrada de lectura según la cual el lector se transforma en protagonista, encarna la esencia marginal del autor medieval y al mismo tiempo muestra su evolución para transformarse en el autor contemporáneo. El objetivo es plantear una reflexión sobre la evolución que ha experimentado la noción de autoría a lo largo de la historia y mostrar cómo en la novela, la memoria actual (representada por la figura del historiador se apropia de la realidad a través de la concreción de la fantasía y de las invenciones o cambios sujetos al proceso de remembranza. Interesa, en última instancia, mostrar que recordar el pasado supone un ejercicio creativo en el que, el historiador también se comporta como autor en la medida en que ofrece una nueva perspectiva anclada en el presente.

  10. Determination of uranium and polonium in Spa rus aura ta by alpha spectrometry

    International Nuclear Information System (INIS)

    Luna P, M.; Renteria, M.; Montero C, M. E.; Manjon C, G.; Diaz, I.

    2012-01-01

    The aim of this study was optimizing conditions for the specific activities determination of some uranium-series radionuclides present in Spa rus aura ta by alpha spectrometry. Determinations of specific activities were conducted varying the type of digestion: acid attack on hot plate, controlled microwave digestion and acid attack after calcination of the sample. The latter procedure was applied only to the case of uranium isotopes determination. The variation in the isotope extraction method consisted of applying the techniques of liquid-liquid extracting using Tributyl phosphate or chromatographic UTEVA resin. Results depending on the type of treatment given to the samples were compared based on obtained chemical yields. The results reveal a higher bioaccumulation of polonium in the liver sample, with activities of 0.809, 2.495 and 2.439 Bq kg -1 fresh wt compared with the fillet. The best chemical yields of polonium were close to 60% for samples that were digested by microwave. In the case of uranium the best chemical yields, close to 80% for fillet, were obtained with a previous calcination of the sample and using the UTEVA resin. (Author)

  11. Satellite observations of peroxyacetyl nitrate from the Aura Tropospheric Emission Spectrometer

    Directory of Open Access Journals (Sweden)

    V. H. Payne

    2014-11-01

    Full Text Available We present a description of the algorithm used to retrieve peroxyacetyl nitrate (PAN concentrations from the Aura Tropospheric Emission Spectrometer (TES. We describe the spectral microwindows, error analysis, and the utilization of a priori and initial guess information provided by the GEOS-Chem global chemical transport model. The TES PAN retrievals contain up to one degree of freedom for signal. In general, the retrievals are most sensitive to PAN in the mid-troposphere. Estimated single-measurement uncertainties are on the order of 30 to 50%. The detection limit for a single TES measurement is dependent on the atmospheric and surface conditions as well as on the instrument noise. For observations where the cloud optical depth is less than 0.5, we find that the TES detection limit for PAN is in the region of 200 to 300 pptv. We show that PAN retrievals capture plumes associated with boreal burning. Retrievals over the Northern Hemisphere Pacific in springtime show spatial features that are qualitatively consistent with the expected distribution of PAN in outflow of Asian pollution.

  12. Next Generation Aura-OMI SO2 Retrieval Algorithm: Introduction and Implementation Status

    Science.gov (United States)

    Li, Can; Joiner, Joanna; Krotkov, Nickolay A.; Bhartia, Pawan K.

    2014-01-01

    We introduce our next generation algorithm to retrieve SO2 using radiance measurements from the Aura Ozone Monitoring Instrument (OMI). We employ a principal component analysis technique to analyze OMI radiance spectral in 310.5-340 nm acquired over regions with no significant SO2. The resulting principal components (PCs) capture radiance variability caused by both physical processes (e.g., Rayleigh and Raman scattering, and ozone absorption) and measurement artifacts, enabling us to account for these various interferences in SO2 retrievals. By fitting these PCs along with SO2 Jacobians calculated with a radiative transfer model to OMI-measured radiance spectra, we directly estimate SO2 vertical column density in one step. As compared with the previous generation operational OMSO2 PBL (Planetary Boundary Layer) SO2 product, our new algorithm greatly reduces unphysical biases and decreases the noise by a factor of two, providing greater sensitivity to anthropogenic emissions. The new algorithm is fast, eliminates the need for instrument-specific radiance correction schemes, and can be easily adapted to other sensors. These attributes make it a promising technique for producing long-term, consistent SO2 records for air quality and climate research. We have operationally implemented this new algorithm on OMI SIPS for producing the new generation standard OMI SO2 products.

  13. A joint data record of tropospheric ozone from Aura-TES and MetOp-IASI

    Directory of Open Access Journals (Sweden)

    H. Oetjen

    2016-08-01

    Full Text Available The Tropospheric Emission Spectrometer (TES on Aura and Infrared Atmospheric Sounding Interferometer (IASI on MetOp-A together provide a time series of 10 years of free-tropospheric ozone with an overlap of 3 years. We characterise the differences between TES and IASI ozone measurements and find that IASI's coarser vertical sensitivity leads to a small (< 5 ppb low bias relative to TES for the free troposphere. The TES-IASI differences are not dependent on season or any other factor and hence the measurements from the two instruments can be merged, after correcting for the offset, in order to study decadal-scale changes in tropospheric ozone. We calculate time series of regional monthly mean ozone in the free troposphere over eastern Asia, the western United States (US, and Europe, carefully accounting for differences in spatial sampling between the instruments. We show that free-tropospheric ozone over Europe and the western US has remained relatively constant over the past decade but that, contrary to expectations, ozone over Asia in recent years does not continue the rapid rate of increase observed from 2004 to 2010.

  14. Building country image process

    Directory of Open Access Journals (Sweden)

    Zubović Jovan

    2005-01-01

    Full Text Available The same branding principles are used for countries as they are used for the products, only the methods are different. Countries are competing among themselves in tourism, foreign investments and exports. Country turnover is at the level that the country's reputation is. The countries that begin as unknown or with a bad image will have limits in operations or they will be marginalized. As a result they will be at the bottom of the international influence scale. On the other hand, countries with a good image, like Germany (despite two world wars will have their products covered with a special "aura".

  15. Updated SO2 emission estimates over China using OMI/Aura observations

    Directory of Open Access Journals (Sweden)

    M. E. Koukouli

    2018-03-01

    Full Text Available The main aim of this paper is to update existing sulfur dioxide (SO2 emission inventories over China using modern inversion techniques, state-of-the-art chemistry transport modelling (CTM and satellite observations of SO2. Within the framework of the EU Seventh Framework Programme (FP7 MarcoPolo (Monitoring and Assessment of Regional air quality in China using space Observations project, a new SO2 emission inventory over China was calculated using the CHIMERE v2013b CTM simulations, 10 years of Ozone Monitoring Instrument (OMI/Aura total SO2 columns and the pre-existing Multi-resolution Emission Inventory for China (MEIC v1.2. It is shown that including satellite observations in the calculations increases the current bottom-up MEIC inventory emissions for the entire domain studied (15–55° N, 102–132° E from 26.30 to 32.60 Tg annum−1, with positive updates which are stronger in winter ( ∼  36 % increase. New source areas were identified in the southwest (25–35° N, 100–110° E as well as in the northeast (40–50° N, 120–130° E of the domain studied as high SO2 levels were observed by OMI, resulting in increased emissions in the a posteriori inventory that do not appear in the original MEIC v1.2 dataset. Comparisons with the independent Emissions Database for Global Atmospheric Research, EDGAR v4.3.1, show a satisfying agreement since the EDGAR 2010 bottom-up database provides 33.30 Tg annum−1 of SO2 emissions. When studying the entire OMI/Aura time period (2005 to 2015, it was shown that the SO2 emissions remain nearly constant before the year 2010, with a drift of −0.51 ± 0.38 Tg annum−1, and show a statistically significant decline after the year 2010 of −1.64 ± 0.37 Tg annum−1 for the entire domain. Similar findings were obtained when focusing on the greater Beijing area (30–40° N, 110–120° E with pre-2010 drifts of −0.17 ± 0.14 and post-2010

  16. Visual–spatial training efficacy in children affected by migraine without aura: a multicenter study

    Directory of Open Access Journals (Sweden)

    Precenzano F

    2017-01-01

    Full Text Available Francesco Precenzano,1,* Maria Ruberto,2,* Lucia Parisi,3 Margherita Salerno,4 Agata Maltese,3 Beatrice Gallai,5 Rosa Marotta,6 Serena Marianna Lavano,7 Francesco Lavano,6 Michele Roccella3 1Clinic of Child and Adolescent Neuropsychiatry, Headache Center for Children and Adolescent. Department of Mental and Physical Health and Preventive Medicine, Università degli Studi della Campania Luigi Vanvitelli, 2Department of Medical-Surgical and Dental Specialties, Università degli Studi della Campania Luigi Vanvitelli, Naples, 3Department of Psychological, Pedagogical and Educational Sciences, 4Sciences for Mother and Child Health Promotion, University of Palermo, Palermo, 5Department of Surgical and Biomedical Sciences, University of Perugia, Perugia, 6Department of Medical and Surgery Sciences, 7Department of Health Sciences, University “Magna Graecia”, Catanzaro, Italy *These authors contributed equally to this work Abstract: Routinely in the clinical practice, children affected by migraine without aura (MwA tend to exhibit severe and persistent difficulties within cognitive processes such as attention, memory, and visual–motor integration (VMI skills. The aim of this study was to assess the visual–spatial and visual–motor abilities among a sample of children with MwA and the effects of a specific computerized training. The study population was composed of 84 patients affected by MwA (39 girls and 45 boys; mean age: 8.91±2.46 years, and they were randomly divided into two groups (group A and group B comparable for age (P=0.581, gender (P=0.826, socioeconomic status (SES, migraine frequency (P=0.415, and intensity (P=0.323. At baseline (T0, the two groups were comparable for movement assessment battery for children (M-ABC and VMI performances. After 6 months of treatment (T1, group A showed lower scores in the dexterity item of M-ABC test (P<0.001 and higher scores in M-ABC global performance centile (P<0.001 and total (P<0.001, visual

  17. Validation of Aura Microwave Limb Sounder stratospheric water vapor measurements by the NOAA frost point hygrometer.

    Science.gov (United States)

    Hurst, Dale F; Lambert, Alyn; Read, William G; Davis, Sean M; Rosenlof, Karen H; Hall, Emrys G; Jordan, Allen F; Oltmans, Samuel J

    2014-02-16

    Differences between stratospheric water vapor measurements by NOAA frost point hygrometers (FPHs) and the Aura Microwave Limb Sounder (MLS) are evaluated for the period August 2004 through December 2012 at Boulder, Colorado, Hilo, Hawaii, and Lauder, New Zealand. Two groups of MLS profiles coincident with the FPH soundings at each site are identified using unique sets of spatiotemporal criteria. Before evaluating the differences between coincident FPH and MLS profiles, each FPH profile is convolved with the MLS averaging kernels for eight pressure levels from 100 to 26 hPa (~16 to 25 km) to reduce its vertical resolution to that of the MLS water vapor retrievals. The mean FPH - MLS differences at every pressure level (100 to 26 hPa) are well within the combined measurement uncertainties of the two instruments. However, the mean differences at 100 and 83 hPa are statistically significant and negative, ranging from -0.46 ± 0.22 ppmv (-10.3 ± 4.8%) to -0.10 ± 0.05 ppmv (-2.2 ± 1.2%). Mean differences at the six pressure levels from 68 to 26 hPa are on average 0.8% (0.04 ppmv), and only a few are statistically significant. The FPH - MLS differences at each site are examined for temporal trends using weighted linear regression analyses. The vast majority of trends determined here are not statistically significant, and most are smaller than the minimum trends detectable in this analysis. Except at 100 and 83 hPa, the average agreement between MLS retrievals and FPH measurements of stratospheric water vapor is better than 1%.

  18. A cloud-ozone data product from Aura OMI and MLS satellite measurements

    Directory of Open Access Journals (Sweden)

    J. R. Ziemke

    2017-11-01

    Full Text Available Ozone within deep convective clouds is controlled by several factors involving photochemical reactions and transport. Gas-phase photochemical reactions and heterogeneous surface chemical reactions involving ice, water particles, and aerosols inside the clouds all contribute to the distribution and net production and loss of ozone. Ozone in clouds is also dependent on convective transport that carries low-troposphere/boundary-layer ozone and ozone precursors upward into the clouds. Characterizing ozone in thick clouds is an important step for quantifying relationships of ozone with tropospheric H2O, OH production, and cloud microphysics/transport properties. Although measuring ozone in deep convective clouds from either aircraft or balloon ozonesondes is largely impossible due to extreme meteorological conditions associated with these clouds, it is possible to estimate ozone in thick clouds using backscattered solar UV radiation measured by satellite instruments. Our study combines Aura Ozone Monitoring Instrument (OMI and Microwave Limb Sounder (MLS satellite measurements to generate a new research product of monthly-mean ozone concentrations in deep convective clouds between 30° S and 30° N for October 2004–April 2016. These measurements represent mean ozone concentration primarily in the upper levels of thick clouds and reveal key features of cloud ozone including: persistent low ozone concentrations in the tropical Pacific of  ∼ 10 ppbv or less; concentrations of up to 60 pphv or greater over landmass regions of South America, southern Africa, Australia, and India/east Asia; connections with tropical ENSO events; and intraseasonal/Madden–Julian oscillation variability. Analysis of OMI aerosol measurements suggests a cause and effect relation between boundary-layer pollution and elevated ozone inside thick clouds over landmass regions including southern Africa and India/east Asia.

  19. Application of Aura OMI L2G Products Compared with NASA MERRA-2 Assimilation

    Science.gov (United States)

    Zeng, Jian; Shen, Suhung; Wei, Jennifer; Johnson, James E.; Su, Jian; Meyer, David J.

    2018-01-01

    The Ozone Monitoring Instrument (OMI) is one of the instruments aboard NASA's Aura satellite. It measures ozone total column and vertical profile, aerosols, clouds, and trace gases including NO2, SO2, HCHO, BrO, and OClO using absorption in the ultraviolet electromagnetic spectrum (280 - 400 nm). OMI Level-2G (L2G) products are based on the pixel-level OMI granule satellite measurements stored within global 0.25 deg. X 0.25 deg. grids, therefore they conserve all the Level 2 (L2) spatial and temporal details for 24 hours of scientific data in one file. The second Modern-Era Retrospective analysis for Research and Applications (MERRA-2) is NASA's atmospheric reanalysis, using an upgraded version of Goddard Earth Observing System Model, version 5 (GEOS-5) data assimilation system. MERRA-2 includes aerosol data reanalysis and improved representations of stratospheric ozone, compared with its predecessor MERRA, in both instantaneous and time-averaged collections. It is found that simply comparing satellite Level-3 products might cause biases, due to lack of detailed temporal and original retrieval information. It is therefore preferable to inter-compare or implement satellite derived physical quantities directly with/to model assimilation with as high temporal and spatial resolutions as possible. This study will demonstrate utilization of OMI L2G daily aerosol and ozone products by comparing them with MERRA-2 hourly aerosol/ozone simulations, matched in both space and time aspects. Both OMI and MERRA-2 products are accessible online through NASA Goddard Earth Sciences Data Information Services Center (GES DISC, https://disc.gsfc.nasa.gov/).

  20. The methylenetetrahydrofolate reductase gene variant C677T influences susceptibility to migraine with aura

    Directory of Open Access Journals (Sweden)

    Sundholm James

    2004-02-01

    Full Text Available Abstract Background The C677T variant in the methylenetetrahydrofolate reductase (MTHFR gene is associated with increased levels of circulating homocysteine and is a mild risk factor for vascular disease. Migraine, with and without aura (MA and MO, is a prevalent and complex neurovascular disorder that may also be affected by genetically influenced hyperhomocysteinaemia. To determine whether the C677T variant in the MTHFR gene is associated with migraine susceptibility we utilised unrelated and family-based case-control study designs. Methods A total of 652 Caucasian migraine cases were investigated in this study. The MTHFR C677T variant was genotyped in 270 unrelated migraine cases and 270 controls as well as 382 affected subjects from 92 multiplex pedigrees. Results In the unrelated case-control sample we observed an over-representation of the 677T allele in migraine patients compared to controls, specifically for the MA subtype (40% vs. 33% (χ2 = 5.70, P = 0.017. The Armitage test for trend indicated a significant dosage effect of the risk allele (T for MA (χ2 = 5.72, P = 0.017. This linear trend was also present in the independent family-based sample (χ2 = 4.25, Padjusted = 0.039. Overall, our results indicate that the T/T genotype confers a modest, yet significant, increase in risk for the MA subtype (odds ratio: 2.0 – 2.5. No increased risk for the MO subtype was observed (P > 0.05. Conclusions In Caucasians, the C677T variant in the MTHFR gene influences susceptibility to MA, but not MO. Investigation into the enzyme activity of MTHFR and the role of homocysteine in the pathophysiology of migraine is warranted.

  1. Migraine with aura and silent brain infarcts lack of mediation of patent foramen ovale.

    Science.gov (United States)

    Calviere, L; Tall, P; Massabuau, P; Bonneville, F; Larrue, V

    2013-12-01

    Population-based studies have shown a heightened prevalence of clinically silent brain infarcts in subjects who have migraine with aura (MA). We sought to determine whether this association could be confirmed in young patients with cryptogenic ischemic stroke, and explored the role of patent foramen ovale (PFO) as a potential underlying mechanism. Patients were selected from a registry of young patients consecutively treated for ischemic stroke in a tertiary university hospital among those without definite cause of stroke. Patients with PFO were matched for age and gender with patients with normal atrial septum. Migraine and MA were evaluated after patient selection and matching. Silent brain infarcts were independently evaluated on MRI. We included 100 patients [60 men; mean age (SD), 44.8 years (8.3)], 50 patients with PFO. We found silent brain infarcts in 36 patients and MA in 13 patients. MA was more frequent in patients with silent brain infarcts than in patients without silent brain infarcts (25.0% vs. 6.3%; OR, 5; 95% CI, 1.4-17.6; P = 0.01). Traditional cardiovascular risk factors were not associated with silent brain infarcts. PFO was neither associated with MA (OR, 1.7; 95% CI, 0.5-5.3) nor silent brain infarcts (OR, 0.7; 95% CI, 0.3-1.5). The association of MA with silent brain infarcts was not altered after adjustment for PFO. Findings suggest that silent brain infarcts in young patients with cryptogenic stroke is associated with MA. We found no evidence for a mediating effect of PFO on this association. © 2013 The Author(s) European Journal of Neurology © 2013 EFNS.

  2. Changes in SO2 and NO2 Pollution over the Past Decade Observed by Aura OMI

    Science.gov (United States)

    Krotkov, N. A.; Li, C.; Lamsal, L. N.; Celarier, E. A.; Marchenko, S. V.; Swartz, W.; Bucsela, E. J.; Fioletov, V.; McLinden, C. A.; Joiner, J.; Bhartia, P. K.; Duncan, B. N.; Dickerson, R. R.

    2014-12-01

    The Ozone Monitoring Instrument (OMI), a NASA partnership with the Netherlands and Finland, flies on the EOS Aura satellite and uses reflected sunlight to measure two critical atmospheric trace gases, nitrogen dioxide (NO2) and sulfur dioxide (SO2), characterizing daily air quality. Both gases and the secondary pollutants they produce (particulate matter, PM2.5, and tropospheric ozone) are among USEPA designated criteria pollutants, posing serious threats to human health and the environment (e.g., acid rain, plant damage, and reduced visibility). A new generation of the OMI standard SO2 and NO2 products (based on critically improved DOAS spectral fitting for NO2 and innovative Principal Component Analysis method for SO2) provides a valuable dataset for studying anthropogenic pollution on local to global scales. Here we highlight some of the OMI observed long-term changes in air quality over several regions. Over the US, average NO2 and SO2 pollution levels have decreased dramatically as a result of both technological improvements (e.g., catalytic converters on cars) and stricter regulations of emissions. We see continued decline in NO2 and SO2 pollution over Europe. Over China OMI observed a ~ 60% increase in NO2 pollution between 2005 and 2013, despite a temporary reversal of the growing trend due to both 2008 Olympic Games and the economic recession in 2009. Chinese SO2 pollution seems to have stabilized since peaking in 2007, probably due to government efforts to curb SO2 emissions from the power sector. We have also observed large increases in both SO2 and NO2 pollution particularly in Eastern India where a number of new large coal power plants have been built in recent years. We expect that further improvements in the OMI NO2 and SO2 products will allow more robust quantification of long-term trends in local to global air quality.

  3. Variability in the Speed of the Brewer-Dobson Circulation as Observed by Aura/MLS

    Science.gov (United States)

    Flury, Thomas; Wu, Dong L.; Read, W. G.

    2013-01-01

    We use Aura/MLS stratospheric water vapour (H2O) measurements as tracer for dynamics and infer interannual variations in the speed of the Brewer-Dobson circulation (BDC) from 2004 to 2011. We correlate one-year time series of H2O in the lower stratosphere at two subsequent pressure levels (68 hPa, approx.18.8 km and 56 hPa, approx 19.9 km at the Equator) and determine the time lag for best correlation. The same calculation is made on the horizontal on the 100 hPa (approx 16.6 km) level by correlating the H2O time series at the Equator with the ones at 40 N and 40 S. From these lag coefficients we derive the vertical and horizontal speeds of the BDC in the tropics and extra-tropics, respectively. We observe a clear interannual variability of the vertical and horizontal branch. The variability reflects signatures of the Quasi Biennial Oscillation (QBO). Our measurements confirm the QBO meridional circulation anomalies and show that the speed variations in the two branches of the BDC are out of phase and fairly well anti-correlated. Maximum ascent rates are found during the QBO easterly phase. We also find that transport of H2O towards the Northern Hemisphere (NH) is on the average two times faster than to the Southern Hemisphere (SH) with a mean speed of 1.15m/s at 100 hPa. Furthermore, the speed towards the NH shows much more interannual variability with an amplitude of about 21% whilst the speed towards the SH varies by only 10 %. An amplitude of 21% is also observed in the variability of the ascent rate at the Equator which is on the average 0.2mm/s.

  4. Ambu AuraOnce versus i-gel laryngeal mask airway in infants and children undergoing surgical procedures

    OpenAIRE

    Alzahem, Abdulrahman M.; Aqil, Mansoor; Alzahrani, Tariq A.; Aljazaeri, Ayman H.

    2017-01-01

    Objectives: To compare the efficacy and performance of the pediatric Ambu AuraOnce (Ambu AO) mask (Ambu, Copenhagen, Denmark) and i-gel mask (Intersurgical Ltd., Wokingham, United Kingdom). Methods: From May 2015 to September 2016, 112 patients, 0-14 years old, underwent elective surgery at a tertiary university hospital (Riyadh, Saudi Arabia). They were randomly assigned to the Ambu AO or i-gel group. Three groups underwent a subgroup analysis: ?5 kg (group 1), 5.1?10.0 kg (group 2), and >10...

  5. La imaginación enfermiza: La ciudad muerta y el gótico en Aura de Carlos Fuentes

    Directory of Open Access Journals (Sweden)

    Miguel Ángel Náter

    2004-04-01

    Full Text Available Este ensayo se acerca a la novela Aura, de Carlos Fuentes, para explorar la reescritura del gótico y, sobre todo, la relación de la ciudad muerta o del pueblo abandonado, desde la perspectiva del espacio apocalíptico, entendido como la paralela desintegración de los espacios, de los cuerpos y de las mentes. El deterioro de la casa, en contraste con el adelanto tecnológico, se vincula con el cuerpo decrépito de la anciana Consuelo. La oscuridad del interior del edificio es correlato del oscurantismo y de la brujería, que producirá la alienación de Felipe Montero. Sobre la base de lo grotesco como lo expone Wolfgang Kayser, y de lo siniestro como lo propone Sigmund Freud, se pretende resaltar la importancia de Aura en la tradición novelística hispanoamericana que intenta presentar una narrativa disidente en relación con la novela del progreso y del adelanto tecnológico. En esa tendencia se incluyen, además, novelas como El lugar sin límites de José Donoso, Pedro Páramo de Juan Rulfo y Casas muertas de Miguel Otero SilvaThis essay represents an approach to the novel of Carlos Fuentes' Aura, a novel which explores the re-writing of the gothic, and above all, the relation of the dead city to the abandoned town, in the perspective of the apocalyptic space understood as the parallel disintegration of the space, of the bodies and the minds. The deterioration of the house, in contrast to the technological progress, is linked to the decrepit body of the old woman, Consuelo. The dark within the building correlates to the obscurantism and witchery that will lead to the alienation of Felipe Montero. On the basis of the grotesque as expounded by Wolfgang Kaiser, and the sinister, as propounded by Freud, the idea is to emphasize the significance of Aura in the Hispanic American tradition, which proposes a dissident narrative against the novel of progress and technological advance. This tendency also includes novels like J. Donoso' El lugar sin

  6. Evaluating climate model performance in the tropics with retrievals of water isotopic composition from Aura TES

    Science.gov (United States)

    Field, Robert; Kim, Daehyun; Kelley, Max; LeGrande, Allegra; Worden, John; Schmidt, Gavin

    2014-05-01

    Observational and theoretical arguments suggest that satellite retrievals of the stable isotope composition of water vapor could be useful for climate model evaluation. The isotopic composition of water vapor is controlled by the same processes that control water vapor amount, but the observed distribution of isotopic composition is distinct from amount itself . This is due to the fractionation that occurs between the abundant H216O isotopes (isotopologues) and the rare and heavy H218O and HDO isotopes during evaporation and condensation. The fractionation physics are much simpler than the underlying moist physics; discrepancies between observed and modeled isotopic fields are more likely due to problems in the latter. Isotopic measurements therefore have the potential for identifying problems that might not be apparent from more conventional measurements. Isotopic tracers have existed in climate models since the 1980s but it is only since the mid 2000s that there have been enough data for meaningful model evaluation in this sense, in the troposphere at least. We have evaluated the NASA GISS ModelE2 general circulation model over the tropics against water isotope (HDO/H2O) retrievals from the Aura Tropospheric Emission Spectrometer (TES), alongside more conventional measurements. A small ensemble of experiments was performed with physics perturbations to the cumulus and planetary boundary layer schemes, done in the context of the normal model development process. We examined the degree to which model-data agreement could be used to constrain a select group of internal processes in the model, namely condensate evaporation, entrainment strength, and moist convective air mass flux. All are difficult to parameterize, but exert strong influence over model performance. We found that the water isotope composition was significantly more sensitive to physics changes than precipitation, temperature or relative humidity through the depth of the tropical troposphere. Among the

  7. Aura OMI observations of regional SO2 and NO2 pollution changes from 2005 to 2015

    Directory of Open Access Journals (Sweden)

    N. A. Krotkov

    2016-04-01

    Full Text Available The Ozone Monitoring Instrument (OMI onboard NASA's Aura satellite has been providing global observations of the ozone layer and key atmospheric pollutant gases, such as nitrogen dioxide (NO2 and sulfur dioxide (SO2, since October 2004. The data products from the same instrument provide consistent spatial and temporal coverage and permit the study of anthropogenic and natural emissions on local-to-global scales. In this paper, we examine changes in SO2 and NO2 over some of the world's most polluted industrialized regions during the first decade of OMI observations. In terms of regional pollution changes, we see both upward and downward trends, sometimes in opposite directions for NO2 and SO2, for different study areas. The trends are, for the most part, associated with economic and/or technological changes in energy use, as well as regional regulatory policies. Over the eastern US, both NO2 and SO2 levels decreased dramatically from 2005 to 2015, by more than 40 and 80 %, respectively, as a result of both technological improvements and stricter regulations of emissions. OMI confirmed large reductions in SO2 over eastern Europe's largest coal-fired power plants after installation of flue gas desulfurization devices. The North China Plain has the world's most severe SO2 pollution, but a decreasing trend has been observed since 2011, with about a 50 % reduction in 2012–2015, due to an economic slowdown and government efforts to restrain emissions from the power and industrial sectors. In contrast, India's SO2 and NO2 levels from coal power plants and smelters are growing at a fast pace, increasing by more than 100 and 50 %, respectively, from 2005 to 2015. Several SO2 hot spots observed over the Persian Gulf are probably related to oil and gas operations and indicate a possible underestimation of emissions from these sources in bottom-up emission inventories. Overall, OMI observations have proved valuable in documenting rapid changes in air

  8. Next-Generation Aura/OMI NO2 and SO2 Products

    Science.gov (United States)

    Krotkov, Nickolay; Yang, Kai; Bucsela, Eric; Lamsal, Lok; Celarier, Edward; Swartz, William; Carn, Simon; Bhartia, Pawan; Gleason, James; Pickering, Ken; hide

    2011-01-01

    The measurement of both SO2 and NO2 gases are recognized as an essential component of atmospheric composition missions. We describe current capabilities and limitations of the operational Aura/OMI NO2 and SO2 data that have been used by a large number of researchers. Analyses of the data and validation studies have brought to light a number of areas in which these products can be expanded and improved. Major improvements for new NASA standard (SP) NO2 product include more accurate tropospheric and stratospheric column amounts, along with much improved error estimates and diagnostics. Our approach uses a monthly NO2 climatology based on the NASA Global Modeling Initiative (GMI) chemistry-transport model and takes advantage of OMI data from cloudy scenes to find clean areas where the contribution from the trap NO2 column is relatively small. We then use a new filtering, interpolation and smoothing techniques for separating the stratospheric and tropospheric components of NO2, minimizing the influence of a priori information. The new algorithm greatly improves the structure of stratospheric features relative to the original SP. For the next-generation OMI SO2 product we plan to implement operationally the offline iterative spectral fitting (ISF) algorithm and re-process the OMI Level-2 SO2 dataset using a priori SO2 and aerosol profiles, clouds, and surface reflectivity appropriate for observation conditions. This will improve the ability to detect and quantify weak tropospheric SO2 loadings. The new algorithm is validated using aircraft in-situ data during field campaigns in China (2005 and 2008) and in Maryland (Frostburg, 2010 and DISCOVER-AQ in July 2011). The height of the SO2 plumes will also be estimated for high SO2 loading cases (e.g., volcanic eruptions). The same SO2 algorithm will be applied to the data from OMPS sensor to be launched on NPP satellite later this year. The next-generation NO2 and SO2 products will provide critical information (e

  9. Aura OMI Observations of Global SO2 and NO2 Pollution from 2005 to 2013

    Science.gov (United States)

    Krotkov, Nickolay; Li, Can; Lamsal, Lok; Celarier, Edward; Marchenko, Sergey; Swartz, William H.; Bucsela, Eric; Fioletov, Vitali; McLinden, Chris; Joiner, Joanna; hide

    2014-01-01

    The Ozone Monitoring Instrument (OMI), a NASA partnership with the Netherlands and Finland, flies on the NASA Aura satellite and uses reflected sunlight to measure the two critical atmospheric trace gases: nitrogen dioxide (NO2) and sulfur dioxide (SO2) characterizing daily air quality. Both gases and the secondary pollutants they produce (particulate matter, PM2.5, and tropospheric ozone) are USEPA designated criteria pollutants, posing serious threats to human health and the environment (e.g., acid rain, plant damage and reduced visibility). Our group at NASA GSFC has developed and maintained OMI standard SO2 and NO2 data products. We have recently released an updated version of the standard NO2 L2 and L3 products (SP v2.1) and continue improving the algorithm. We are currently in the process of releasing next generation pollution SO2 product, based on an innovative Principal Component Analysis (PCA) algorithm, which greatly reduces the noise and biases. These new standard products provide valuable datasets for studying anthropogenic pollution on local to global scales. Here we highlight some of the OMI observed changes in air quality over several regions. Over the US average NO2 and SO2 pollution levels had decreased dramatically as a result of both technological improvements (e.g., catalytic converters on cars) and stricter regulations of emissions. We see continued decline in pollution over Europe. Over China OMI observed an increase of about 60 percent in NO2 pollution between 2005 and 2013, despite a temporal reversal of the growing trend due to both 2008 Olympic Games and the economic recession in 2009. Chinese SO2 pollution seems to have stabilized since peaking in 2007, probably due to government efforts to curb SO2 emissions from the power sector. We have also observed large increases in both SO2 and NO2 pollution particularly in Eastern India where a number of large new coal power plants had been built in recent years. We expect that further

  10. Walter Benjamin in the Age of Digital Reproduction: Aura in Education--A Rereading of "The Work of Art in the Age of Mechanical Reproduction"

    Science.gov (United States)

    Peim, Nick

    2007-01-01

    This paper considers a key text in the field of Cultural Studies for its relevance to questions about the identity of knowledge in education. The concept of "aura" arises as being of special significance in "The Work of Art in the Age of Mechanical Reproduction" as a way of understanding the change that occurs to art when mass reproduction becomes…

  11. OMI/Aura NO2 Cloud-Screened Total and Tropospheric Column Daily L3 Global 0.25deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI/Aura Level-3 Global Gridded(0.25x0.25 deg) Nitrogen Dioxide Product "OMNO2d" is now released (Jan 10, 2013) to the public from the NASA Goddard Earth...

  12. Fatores desencadeantes de crises de migrânea em pacientes com migrânea sem aura Precipitating factors of migraine attacks in patients with migraine without aura

    Directory of Open Access Journals (Sweden)

    Ricardo Ierusalimschy

    2002-09-01

    Full Text Available Com o objetivo de estudar a distribuição de fatores desencadeantes de migrânea em uma população determinada, foram avaliados, através de entrevista pessoal, 100 pacientes que preenchiam os critérios diagnósticos para migrânea sem aura propostos pela Sociedade Internacional de Cefaléia. O estresse foi o desencadeante mais citado, respondendo pelo surgimento de crises de migrânea em 76% dos pacientes. Em seguida, em ordem de frequência decrescente, foram citados: estímulos sensoriais (75%, privação do sono (49%, jejum (48%, fatores ambientais (47%, alimentos (46%, menstruação (39%, fadiga (35%, bebidas alcoólicas (28%, sono prolongado (27%, cafeína (22%, esforço físico (20%, trauma craniano (20%, viagens (4%, atividade sexual (3%, medicamentos (2%, os movimentos do pescoço (2%, tabagismo (1% e uso de travesseiro baixo (1%. Conclui-se que determinados fatores parecem desempenhar papel importante na precipitação da migrânea.To study the distribution of triggers of migraine in a selected population, 100 patients who fulfilled the diagnostic criteria for migraine without aura as proposed by the International Headache Societywere evaluated by means of a personal interview. Stress was the most cited trigger, triggering migraine in 76%. Afterwards, in descending order of frequency, were cited sensorial stimuli (75%, sleep deprivation (49%, hunger (48%, environmental factors (47%, food (46%, menses (39%, fatigue (35%, alcohol (28%, sleep excess (27%, cafeine (22%, physical exertion (20%, head trauma (20%, trips (4%, sexual activity (3%, medications (2%, neck movements (2%, smoking (1% and the use of a low pillow (1%. It is concluded that certain factors seem to play an important role in the triggering of migraine.

  13. A genotype-phenotype analysis of the 8q22.1 variant in migraine with aura

    DEFF Research Database (Denmark)

    Esserlind, A-L; Kirchmann, M; Hauge, A W

    2012-01-01

    -2002 and 2005-2006, and diagnosed according to the International Classification of Headache Disorders (ICHD-II) using a validated physician-conducted semi-structured interview. A large number of clinical characteristics were systematically determined. Caucasians of Danish ancestry diagnosed with MA...... and migraine. The aim of this study is to evaluate the association of clinical characteristics in migraine with aura (MA) with the newly discovered minor allele A of rs1835740 at 8q22.1. Methods: Participants were recruited from the Danish Headache Center and from specialist practices during the periods 1999......-significant tendency towards milder migraine headache characteristics and fewer accompanying symptoms. These tendencies were not increased in homozygote carriers. Conclusion: None of the clinical characteristics of MA were significantly influenced by the common susceptibility variant on 8q22.1....

  14. Assessment of Responsiveness to Everyday Non-Noxious Stimuli in Pain-Free Migraineurs With Versus Without Aura.

    Science.gov (United States)

    Granovsky, Yelena; Shor, Merav; Shifrin, Alla; Sprecher, Elliot; Yarnitsky, David; Bar-Shalita, Tami

    2018-03-27

    Migraineurs with aura (MWA) express higher interictal response to non-noxious and noxious experimental sensory stimuli compared with migraineurs without aura (MWoA), but whether these differences also prevail in response to everyday non-noxious stimuli is not yet explored. This is a cross-sectional study testing 53 female migraineurs (30 MWA; 23 MWoA) who underwent a wide battery of noxious psychophysical testing at a pain-free phase, and completed a Sensory Responsiveness Questionnaire and pain-related psychological questionnaires. The MWA group showed higher questionnaire-based sensory over-responsiveness (P = .030), higher magnitude of pain temporal summation (P = .031) as well as higher monthly attack frequency (P = .027) compared with the MWoA group. Overall, 45% of migraineurs described abnormal sensory (hyper- or hypo-) responsiveness; its incidence was higher among MWA (19 of 30, 63%) versus MWoA (6 of 23, 27%, P = .012), with an odds ratio of 3.58 for MWA. Sensory responsiveness scores were positively correlated with attack frequency (r = .361, P = .008) and temporal summation magnitude (r = .390, P = .004), both regardless of migraine type. MWA express higher everyday sensory responsiveness than MWoA, in line with higher response to experimental noxious stimuli. Abnormal scores of sensory responsiveness characterize people with sensory modulation dysfunction, suggesting possible underlying mechanisms overlap, and possibly high incidence of both clinical entities. This article presents findings distinguishing MWA, showing enhanced pain amplification, monthly attack frequency, and over-responsiveness to everyday sensations, compared with MWoA. Further, migraine is characterized by a high incidence of abnormal responsiveness to everyday sensation, specifically sensory over-responsiveness, that was also found related to pain. Copyright © 2018 The American Pain Society. Published by Elsevier Inc. All rights reserved.

  15. Aura OMI observations of changes in SO2 and NO2 emissions at local, regional and global scales

    Science.gov (United States)

    Krotkov, N. A.; McLinden, C. A.; Li, C.; Lamsal, L. N.; Celarier, E. A.; Marchenko, S. V.; Swartz, W.; Bucsela, E. J.; Joiner, J.; Duncan, B. N.; Boersma, K. F.; Veefkind, P.; Levelt, P.; Fioletov, V.; Dickerson, R. R.; He, H.; Lu, Z.; Streets, D. G.

    2015-12-01

    Space-based pollution monitoring from current and planned satellite UV-Vis spectrometers play an increasingly important role in studies of tropospheric chemistry and also air quality applications to help mitigate anthropogenic and natural impacts on sensitive ecosystems, and human health. We present long-term changes in tropospheric SO2 and NO2 over some of the most polluted industrialized regions of the world observed by the Ozone Monitoring Instrument (OMI) onboard NASA's Aura satellite. Using OMI data, we identified about 400 SO2 "hot spots" and estimated emissions from them. In many regions emissions and their ambient pollution levels have decreased significantly, such as over eastern US, Europe and China. OMI observed about 50% reduction in SO2 and NO2 pollution over the North China plain in 2012-2014 that can be attributed to both government efforts to restrain emissions from the power and industrial sectors and the economic slowdown. While much smaller, India's SO2 and NO2 emissions from coal power plants and smelters are growing at a fast pace, increasing by about 200% and 50% from 2005 to 2014. Over Europe and the US OMI-observed trends agree well with those from available in situ measurements of surface concentrations, deposition and emissions data. However, for some regions (e.g., Mexico, Middle East) the emission inventories may be incomplete and OMI can provide emission estimates for missing sources, such as SO2 sources observed over the Persian Gulf. It is essential to continue long-term overlapping satellite data records of air quality with increased spatial and temporal resolution to resolve point pollution sources using oversampling technique. We discuss how Aura OMI pollution measurements and emission estimates will be continued with the US JPSS and European Sentinel series for the next 20 years and further enhanced by the addition of three geostationary UV-VIS instruments.

  16. A cohort evaluation of clinical use and performance characteristics of Ambu® AuraGain™: A prospective observational study

    Directory of Open Access Journals (Sweden)

    Devangi A Parikh

    2017-01-01

    Full Text Available Background and Aims: Ambu® AuraGain™ (AG (Ambu, Ballerup, Denmark is a supraglottic device which has a design facilitating its use as a conduit for intubation. We designed this prospective observational study to assess the ease of AG placement in paralysed patients, determine its position and alignment to the glottis and assess its utility as a conduit for intubation. Methods: One hundred patients, aged 18–60 years, American Society of Anesthesiologists physical status I–II, undergoing elective surgery under general anaesthesia were included in the study. The ease and number of attempts for successful insertion, ease of gastric tube insertion, leak pressures, fibre-optic grade of view, number of attempts and time for tracheal intubation, time for AG removal and complications were recorded. The mean, standard deviation (SD, interquartile range (IQR and range were calculated. The upper limit of confidence interval for overall failure rate was calculated using Wilson's score method. Results: AG was successfully inserted in all patients. The mean (SD time taken for insertion was 17.32 (8.48 s. The median [IQR] leak pressures were 24 [20–28] cm of H2O. Optimal laryngeal view for intubation was obtained in 68 patients. Eighty-eight patients could be intubated in the first attempt. Five patients could not be intubated. The overall failure rate of device was 9%. Conclusion: AMBU® AuraGain™ serves as an effective ventilating aid, but caution is suggested before using it as a conduit for endotracheal intubation.

  17. Susceptibility to migraine with aura: an analysis of the CACNA1A gene in the population of Valle Central de Costa Rica

    International Nuclear Information System (INIS)

    Rodriguez Porras, Luis Roberto

    2005-01-01

    The aim is to assess the role of the CACNA1A gene in the pathogenesis of migraine with aura, in a population of Valle Central Costa Rica, so as to make a clinical description of patients analyzed. 174 patients (diagnosed with migraine with aura) were studied and both parents with the genetic markers D19S221, D19S1150, D19S226 located at 2.5,0 and 2.5 cM respectively of CACNA1A. The markers were amplified by PCR and examined in an automatic DNA sequencers. There was no difference between gene frequencies of patients and the control group. The results no support the hypothesis of migraine as a channelopathy analyzed gene. (author) [es

  18. Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults

    OpenAIRE

    Williams, Daryl Lindsay; Zeng, James M.; Alexander, Karl D.; Andrews, David T.

    2012-01-01

    We conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I–IV) were randomly allocated to receive the LMAU or AMBU and were blinded to device selection. Patients received a standardized anesthetic and all airway devices were inserted by trained anaesthetists. Size selection was guided by manufactur...

  19. Differences in short-term primary motor cortex synaptic potentiation as assessed by repetitive transcranial magnetic stimulation in migraine patients with and without aura.

    Science.gov (United States)

    Conte, Antonella; Barbanti, Piero; Frasca, Vittorio; Iacovelli, Elisa; Gabriele, Maria; Giacomelli, Elena; Aurilia, Cinzia; Pichiorri, Floriana; Gilio, Francesca; Inghilleri, Maurizio

    2010-01-01

    To find out more about glutamatergic and gabaergic transmission in migraine, in this study we investigated glutamate-dependent short-term synaptic potentiation and GABA-dependent inhibitory cortical interneuron excitability as assessed by 5Hz-rTMS delivered over primary motor cortex (M1) (motor evoked potential, MEP, amplitude facilitation and cortical silent period, CSP, duration lengthening) in migraine patients with (MA) and without aura (MwoA) and healthy controls. We studied 37 patients with migraine (19 MA and 18 MwoA) and 19 healthy control subjects. 5Hz-rTMS was delivered at 120% resting motor threshold to the hand motor area of the left hemisphere with the target muscle at rest and during contraction. Three of the MA patients were also tested at the end of visual aura during a spontaneous migraine attack. ANOVA showed that the MEP significantly increased in size and CSP significantly lengthened during 5Hz-rTMS in the three groups tested. The 5Hz-rTMS-induced MEP facilitation differed significantly being highest in MA patients. In the three patients tested both ictally and interictally the MEP increased during the interictal session but remained unchanged when the visual aura ended. Our study shows that the neurophysiological feature that differentiates MA patients from MwoA patients and healthy controls is an abnormal M1 susceptibility to 5Hz-rTMS both outside and during the attack suggesting that glutamate-dependent short-term M1 cortical potentiation patterns differ in migraine with and without aura. Copyright 2009 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  20. Assessment and Applications of NASA Ozone Data Products Derived from Aura OMI-MLS Satellite Measurements in Context of the GMI Chemical Transport Model

    Science.gov (United States)

    Ziemke, J. R.; Olsen, M. A.; Witte, J. C.; Douglass, A. R.; Strahan, S. E.; Wargan, K.; Liu, X.; Schoeberl, M. R.; Yang, K.; Kaplan, T. B.; hide

    2013-01-01

    Measurements from the Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS), both onboard the Aura spacecraft, have been used to produce daily global maps of column and profile ozone since August 2004. Here we compare and evaluate three strategies to obtain daily maps of tropospheric and stratospheric ozone from OMI and MLS measurements: trajectory mapping, direct profile retrieval, and data assimilation. Evaluation is based upon an assessment that includes validation using ozonesondes and comparisons with the Global Modeling Initiative (GMI) chemical transport model (CTM). We investigate applications of the three ozone data products from near-decadal and inter-annual timescales to day-to-day case studies. Zonally averaged inter-annual changes in tropospheric ozone from all of the products in any latitude range are of the order 1-2 Dobson Units while changes (increases) over the 8-year Aura record investigated http://eospso.gsfc.nasa.gov/atbd-category/49 vary approximately 2-4 Dobson Units. It is demonstrated that all of the ozone products can measure and monitor exceptional tropospheric ozone events including major forest fire and pollution transport events. Stratospheric ozone during the Aura record has several anomalous inter-annual events including stratospheric warming split events in the Northern Hemisphere extra-tropics that are well captured using the data assimilation ozone profile product. Data assimilation with continuous daily global coverage and vertical ozone profile information is the best of the three strategies at generating a global tropospheric and stratospheric ozone product for science applications.

  1. Global and Seasonal Distributions of CHOCHO and HCHO Observed by the Ozone Monitoring Instrument on EOS Aura

    Science.gov (United States)

    Kurosu, T. P.; Fu, T.; Volkamer, R.; Millet, D. B.; Chance, K.

    2006-12-01

    Over the two years since its launch in July 2004, the Ozone Monitoring Instrument (OMI) on EOS Aura has demonstrated the capability to routinely monitor the volatile organic compounds (VOCs) formaldehyde (HCHO) and glyoxal (CHOCHO). OMI's daily global coverage and spatial resolution as high as 13x24 km provides a unique data set of these molecules for the study of air quality from space. We present the first study of global seasonal distributions of CHOCHO from space, derived from a year of OMI observations. CHOCHO distributions are compared to simultaneous retrievals of HCHO from OMI, providing a first indication of seasonally resolved ratios of these VOCs on a global scale. Satellite retrievals are compared to global simulations of HCHO and CHOCHO, based on current knowledge of sources and sinks, using the GEOS-Chem global chemistry and transport model. Formaldehyde is both directly emitted and also produced from the oxidation of many VOCs, notably biogenic isoprene, and is removed by photolysis and oxidation. Precursors of glyoxal include isoprene, monoterpenes, and aromatics from anthropogenic, biogenic, and biomass burning emissions; it is removed by photolysis, oxidation by OH, dry/wet deposition, and aerosol uptake. As a case study, satellite observations will also be compared to ground-based measurements taken during the Pearl River Delta 2006 field campaign near Guangzhou, China, where high glyoxal concentrations are frequently observed from space.

  2. Evidence of Convective Redistribution of Carbon Monoxide in Aura Tropospheric Emission Sounder (TES) and Microwave Limb Sounder (MLS) Observations

    Science.gov (United States)

    Manyin, Michael; Douglass, Anne; Schoeberl, Mark

    2010-01-01

    Vertical convective transport is a key element of the tropospheric circulation. Convection lofts air from the boundary layer into the free troposphere, allowing surface emissions to travel much further, and altering the rate of chemical processes such as ozone production. This study uses satellite observations to focus on the convective transport of CO from the boundary layer to the mid and upper troposphere. Our hypothesis is that strong convection associated with high rain rate regions leads to a correlation between mid level and upper level CO amounts. We first test this hypothesis using the Global Modeling Initiative (GMI) chemistry and transport model. We find the correlation is robust and increases as the precipitation rate (the strength of convection) increases. We next examine three years of CO profiles from the Tropospheric Emission Sounder (TES) and Microwave Limb Sounder (MLS) instruments aboard EOS Aura. Rain rates are taken from the Tropical Rainfall Measuring Mission (TRMM) 3B-42 multi-satellite product. Again we find a correlation between mid-level and upper tropospheric CO, which increases with rain rate. Our result shows the critical importance of tropical convection in coupling vertical levels of the troposphere in the transport of trace gases. The effect is seen most clearly in strong convective regions such as the Inter-tropical Convergence Zone.

  3. Environmental drivers of variability in the movement ecology of turkey vultures (Cathartes aura) in North and South America.

    Science.gov (United States)

    Dodge, Somayeh; Bohrer, Gil; Bildstein, Keith; Davidson, Sarah C; Weinzierl, Rolf; Bechard, Marc J; Barber, David; Kays, Roland; Brandes, David; Han, Jiawei; Wikelski, Martin

    2014-01-01

    Variation is key to the adaptability of species and their ability to survive changes to the Earth's climate and habitats. Plasticity in movement strategies allows a species to better track spatial dynamics of habitat quality. We describe the mechanisms that shape the movement of a long-distance migrant bird (turkey vulture, Cathartes aura) across two continents using satellite tracking coupled with remote-sensing science. Using nearly 10 years of data from 24 satellite-tracked vultures in four distinct populations, we describe an enormous amount of variation in their movement patterns. We related vulture movement to environmental conditions and found important correlations explaining how far they need to move to find food (indexed by the Normalized Difference Vegetation Index) and how fast they can move based on the prevalence of thermals and temperature. We conclude that the extensive variability in the movement ecology of turkey vultures, facilitated by their energetically efficient thermal soaring, suggests that this species is likely to do well across periods of modest climate change. The large scale and sample sizes needed for such analysis in a widespread migrant emphasizes the need for integrated and collaborative efforts to obtain tracking data and for policies, tools and open datasets to encourage such collaborations and data sharing.

  4. Effects of habitat and time of day on flock size of Turkey Vultures in Cuba (Cathartes aura

    Directory of Open Access Journals (Sweden)

    Piotr Tryjanowski

    2018-01-01

    Full Text Available In agricultural landscapes, the Turkey Vulture Cathartes aura feeds mainly on carcases of domestic animals. In spring 2017, data on 214 flocks of Turkey vultures were collected in a road survey in Cuba (in total 2384 km. Turkey Vultures were found to be common accross Cuba, but flock size varied between habitats, reaching a maximum of 43 in valleys and 31 in agricultural landscapes with domestic animal farms. Vultures were active throughout the day, but the time of day did not significantly affect flock size. This study corroborates previous studies which suggested that carrion resources located in agricultural habitats and river valleys is crucial for the continued survival of this still abundant species. Changes in Cuba’s socio-political system in the near future will likely impact agricultural practices, and this in turn will likely affect Turkey Vultures. Our study may serve as a baseline against which future population changes and flocking behaviour of Turkey Vultures can be compared.

  5. Characteristics of Water Vapor in the UTLS over the Tibetan Plateau Based on AURA/MLS Observations

    Directory of Open Access Journals (Sweden)

    Yi Sun

    2017-01-01

    Full Text Available Water vapor (WV has a vital effect on global climate change. Using satellite data observed by AURA/MLS and ERA-Interim reanalysis datasets, the spatial distributions and temporal variations of WV were analyzed. It was found that high WV content in the UTLS over the southern Tibetan Plateau is more apparent in summer, due to monsoon-induced strong upward motions. The WV content showed the opposite distribution at 100 hPa, though, during spring and winter. And a different distribution at 121 hPa indicated that the difference in WV content between the northern and southern plateau occurs between 121 and 100 hPa in spring and between 147 and 121 hPa in winter. In the UTLS, it diminishes rapidly with increase in altitude in these two seasons, and it shows a “V” structure in winter. There has been a weak increasing trend in WV at 100 hPa, but a downtrend at 147 and 215 hPa, during the past 12 years. At the latter two heights, the WV content in summer has been much higher than in other seasons. Furthermore, WV variation showed a rough wave structure in spring and autumn at 215 hPa. The variation of WV over the Tibetan Plateau is helpful in understanding the stratosphere-troposphere exchange (STE and climate change.

  6. Imaging

    International Nuclear Information System (INIS)

    Kellum, C.D.; Fisher, L.M.; Tegtmeyer, C.J.

    1987-01-01

    This paper examines the advantages of the use of excretory urography for diagnosis. According to the authors, excretory urography remains the basic radiologic examination of the urinary tract and is the foundation for the evaluation of suspected urologic disease. Despite development of the newer diagnostic modalities such as isotope scanning, ultrasonography, CT, and magnetic resonsance imaging (MRI), excretory urography has maintained a prominent role in ruorradiology. Some indications have been altered and will continue to change with the newer imaging modalities, but the initial evaluation of suspected urinary tract structural abnormalities; hematuria, pyuria, and calculus disease is best performed with excretory urography. The examination is relatively inexpensive and simple to perform, with few contraindictions. Excretory urography, when properly performed, can provide valuable information about the renal parenchyma, pelvicalyceal system, ureters, and urinary bladder

  7. Effectiveness and safety of Nintendo Wii Fit PlusTM training in children with migraine without aura: a preliminary study

    Directory of Open Access Journals (Sweden)

    Esposito M

    2013-11-01

    Full Text Available Maria Esposito,1 Maria Ruberto,2 Francesca Gimigliano,1,2 Rosa Marotta,3 Beatrice Gallai,4 Lucia Parisi,5 Serena Marianna Lavano,3 Michele Roccella,5 Marco Carotenuto11Center for Childhood Headache, Child and Adolescent Neuropsychiatry Clinic, Department of Mental Health, Physical and Preventive Medicine, 2Department of Odonto-Stomathologic Disciplines, Pathology – Orthopedic Sciences, Second University of Naples, Naples, Italy; 3Department of Psychiatry, “Magna Graecia” University of Catanzaro, Catanzaro, Italy; 4Unit of Child and Adolescent Neuropsychiatry, University of Perugia, Perugia, Italy; 5Child Neuropsychiatry, Department of Psychology, University of Palermo, Palermo, ItalyBackground: Migraine without aura (MoA is a painful syndrome, particularly in childhood; it is often accompanied by severe impairments, including emotional dysfunction, absenteeism from school, and poor academic performance, as well as issues relating to poor cognitive function, sleep habits, and motor coordination.Materials and methods: The study population consisted of 71 patients affected by MoA (32 females, 39 males (mean age: 9.13±1.94 years; the control group consisted of 93 normally developing children (44 females, 49 males (mean age: 8.97±2.03 years recruited in the Campania school region. The entire population underwent a clinical evaluation to assess total intelligence quotient level, visual-motor integration (VMI skills, and motor coordination performance, the later using the Movement Assessment Battery for Children (M-ABC. Children underwent training using the Wii-balance board and Nintendo Wii Fit Plus™ software (Nintendo Co, Ltd, Kyoto, Japan; training lasted for 12 weeks and consisted of three 30-minute sessions per week at their home.Results: The two starting populations (MoA and controls were not significantly different for age (P=0.899 and sex (P=0.611. M-ABC and VMI performances at baseline (T0 were significantly different in dexterity

  8. Recent divergences in stratospheric water vapor measurements by frost point hygrometers and the Aura Microwave Limb Sounder.

    Science.gov (United States)

    Hurst, Dale F; Read, William G; Vömel, Holger; Selkirk, Henry B; Rosenlof, Karen H; Davis, Sean M; Hall, Emrys G; Jordan, Allen F; Oltmans, Samuel J

    2016-09-08

    Balloon-borne frost point hygrometers (FPs) and the Aura Microwave Limb Sounder (MLS) provide high-quality vertical profile measurements of water vapor in the upper troposphere and lower stratosphere (UTLS). A previous comparison of stratospheric water vapor measurements by FPs and MLS over three sites - Boulder, Colorado (40.0° N); Hilo, Hawaii (19.7° N); and Lauder, New Zealand (45.0° S) - from August 2004 through December 2012 not only demonstrated agreement better than 1% between 68 and 26 hPa but also exposed statistically significant biases of 2 to 10% at 83 and 100 hPa (Hurst et al., 2014). A simple linear regression analysis of the FP-MLS differences revealed no significant long-term drifts between the two instruments. Here we extend the drift comparison to mid-2015 and add two FP sites - Lindenberg, Germany (52.2° N), and San José, Costa Rica (10.0° N) - that employ FPs of different manufacture and calibration for their water vapor soundings. The extended comparison period reveals that stratospheric FP and MLS measurements over four of the five sites have diverged at rates of 0.03 to 0.07 ppmv year -1 (0.6 to 1.5% year -1 ) from ~2010 to mid-2015. These rates are similar in magnitude to the 30-year (1980-2010) average growth rate of stratospheric water vapor (~ 1% year -1 ) measured by FPs over Boulder (Hurst et al., 2011). By mid-2015, the FP-MLS differences at some sites were large enough to exceed the combined accuracy estimates of the FP and MLS measurements.

  9. The Global Structure of UTLS Ozone in GEOS-5: A Multi-Year Assimilation of EOS Aura Data

    Science.gov (United States)

    Wargan, Krzysztof; Pawson, Steven; Olsen, Mark A.; Witte, Jacquelyn C.; Douglass, Anne R.; Ziemke, Jerald R.; Strahan, Susan E.; Nielsen, J. Eric

    2015-01-01

    Eight years of ozone measurements retrieved from the Ozone Monitoring Instrument (OMI) and the Microwave Limb Sounder, both on the EOS Aura satellite, have been assimilated into the Goddard Earth Observing System version 5 (GEOS-5) data assimilation system. This study thoroughly evaluates this assimilated product, highlighting its potential for science. The impact of observations on the GEOS-5 system is explored by examining the spatial distribution of the observation-minus-forecast statistics. Independent data are used for product validation. The correlation coefficient of the lower-stratospheric ozone column with ozonesondes is 0.99 and the bias is 0.5%, indicating the success of the assimilation in reproducing the ozone variability in that layer. The upper-tropospheric assimilated ozone column is about 10% lower than the ozonesonde column but the correlation is still high (0.87). The assimilation is shown to realistically capture the sharp cross-tropopause gradient in ozone mixing ratio. Occurrence of transport-driven low ozone laminae in the assimilation system is similar to that obtained from the High Resolution Dynamics Limb Sounder (HIRDLS) above the 400 K potential temperature surface but the assimilation produces fewer laminae than seen by HIRDLS below that surface. Although the assimilation produces 5 - 8 fewer occurrences per day (up to approximately 20%) during the three years of HIRDLS data, the interannual variability is captured correctly. This data-driven assimilated product is complementary to ozone fields generated from chemistry and transport models. Applications include study of the radiative forcing by ozone and tracer transport near the tropopause.

  10. Effectiveness and safety of Nintendo Wii Fit Plus™ training in children with migraine without aura: a preliminary study.

    Science.gov (United States)

    Esposito, Maria; Ruberto, Maria; Gimigliano, Francesca; Marotta, Rosa; Gallai, Beatrice; Parisi, Lucia; Lavano, Serena Marianna; Roccella, Michele; Carotenuto, Marco

    2013-01-01

    Migraine without aura (MoA) is a painful syndrome, particularly in childhood; it is often accompanied by severe impairments, including emotional dysfunction, absenteeism from school, and poor academic performance, as well as issues relating to poor cognitive function, sleep habits, and motor coordination. The study population consisted of 71 patients affected by MoA (32 females, 39 males) (mean age: 9.13±1.94 years); the control group consisted of 93 normally developing children (44 females, 49 males) (mean age: 8.97±2.03 years) recruited in the Campania school region. The entire population underwent a clinical evaluation to assess total intelligence quotient level, visual-motor integration (VMI) skills, and motor coordination performance, the later using the Movement Assessment Battery for Children (M-ABC). Children underwent training using the Wii-balance board and Nintendo Wii Fit Plus™ software (Nintendo Co, Ltd, Kyoto, Japan); training lasted for 12 weeks and consisted of three 30-minute sessions per week at their home. The two starting populations (MoA and controls) were not significantly different for age (P=0.899) and sex (P=0.611). M-ABC and VMI performances at baseline (T0) were significantly different in dexterity, balance, and total score for M-ABC (PWii training (T1), MoA children showed a significant improvement in M-ABC global performance (Pbalance (PWii Fit Plus™ system as a rehabilitative device for the visuomotor and balance skills impairments among children affected by MoA, even if further research and longer follow-up are needed.

  11. Reusing Joint Polar Satellite System (jpss) Ground System Components to Process AURA Ozone Monitoring Instrument (omi) Science Products

    Science.gov (United States)

    Moses, J. F.; Jain, P.; Johnson, J.; Doiron, J. A.

    2017-12-01

    New Earth observation instruments are planned to enable advancements in Earth science research over the next decade. Diversity of Earth observing instruments and their observing platforms will continue to increase as new instrument technologies emerge and are deployed as part of National programs such as Joint Polar Satellite System (JPSS), Geostationary Operational Environmental Satellite system (GOES), Landsat as well as the potential for many CubeSat and aircraft missions. The practical use and value of these observational data often extends well beyond their original purpose. The practicing community needs intuitive and standardized tools to enable quick unfettered development of tailored products for specific applications and decision support systems. However, the associated data processing system can take years to develop and requires inherent knowledge and the ability to integrate increasingly diverse data types from multiple sources. This paper describes the adaptation of a large-scale data processing system built for supporting JPSS algorithm calibration and validation (Cal/Val) node to a simplified science data system for rapid application. The new configurable data system reuses scalable JAVA technologies built for the JPSS Government Resource for Algorithm Verification, Independent Test, and Evaluation (GRAVITE) system to run within a laptop environment and support product generation and data processing of AURA Ozone Monitoring Instrument (OMI) science products. Of particular interest are the root requirements necessary for integrating experimental algorithms and Hierarchical Data Format (HDF) data access libraries into a science data production system. This study demonstrates the ability to reuse existing Ground System technologies to support future missions with minimal changes.

  12. The relationship between levels of plasma-soluble urokinase plasminogen activator receptor (suPAR) and presence of migraine attack and aura.

    Science.gov (United States)

    Yılmaz, Nigar; Yılmaz, Mustafa; Sirin, Burcu; Yılmaztekin, Sureyya; Kutlu, Gülnihal

    2017-10-01

    Migraine is one of the most common types of pain associated with sterile inflammatory conditions. Soluble urokinase plasminogen activator receptor (suPAR) is a potential novel inflammatory marker. We aim to determine the association between serum values of suPAR, procalcitonin, fibrinogen, and high-sensitivity C-reactive protein (hs-CRP) and migraine disease characteristics. The study involved a total of 60 migraine patients (33 patients in the interictal period, 27 patients in the attack period) and 30 healthy individuals. The serum values of suPAR were found to be significantly higher in migraine patients in the attack period than in migraine patients in the interictal period, and in healthy individuals (p migraine with aura patients than in migraine without aura patients. When we subdivided migraine patients according to frequency of attack (attacks/month), significant differences were found between the suPAR and procalcitonin levels (measured during the attack period) of those in the frequent-attack group (4-5 or more) versus those in the less frequent attack group (less than 4). Serum levels of procalcitonin were shown to be significantly higher in migraine patients during the attack period compared with migraine patients in the interictal period and in control subjects (p = .001 for both). Significant differences were found between plasma levels of fibrinogen in migraine patients versus control subjects (p migraine patients versus the control group. These findings may show that presenting a high level of suPAR in migraine patients with attack and aura results to predisposition to occurring on the symptoms and that high levels of suPAR, procalcitonin and fibrinogen in patients with migraine result in neurogenic inflammation during migraine headaches.

  13. Comparison of aerosol optical depths from the Ozone Monitoring Instrument (OMI on Aura with results from airborne sunphotometry, other space and ground measurements during MILAGRO/INTEX-B

    Directory of Open Access Journals (Sweden)

    J. M. Livingston

    2009-09-01

    Full Text Available Airborne sunphotometer measurements are used to evaluate retrievals of extinction aerosol optical depth (AOD from spatially coincident and temporally near-coincident measurements by the Ozone Monitoring Instrument (OMI aboard the Aura satellite during the March 2006 Megacity Initiative-Local And Global Research Observations/Phase B of the Intercontinental Chemical Transport Experiment (MILAGRO/INTEX-B. The 14-channel NASA Ames Airborne Tracking Sunphotometer (AATS flew on nine missions over the Gulf of Mexico and four in or near the Mexico City area. Retrievals of AOD from near-coincident AATS and OMI measurements are compared for three flights over the Gulf of Mexico for flight segments when the aircraft flew at altitudes 60–70 m above sea level, and for one flight over the Mexico City area where the aircraft was restricted to altitudes ~320–800 m above ground level over the rural area and ~550–750 m over the city. OMI-measured top of atmosphere (TOA reflectances are routinely inverted to yield aerosol products such as AOD and aerosol absorption optical depth (AAOD using two different retrieval algorithms: a near-UV (OMAERUV and a multiwavelength (OMAERO technique. This study uses the archived Collection 3 data products from both algorithms. In particular, AATS and OMI AOD comparisons are presented for AATS data acquired in 20 OMAERUV retrieval pixels (15 over water and 19 OMAERO pixels (also 15 over water. At least four pixels for one of the over-water coincidences and all pixels for the over-land case were cloud-free. Coincident AOD retrievals from 17 pixels of the Moderate Resolution Imaging Spectroradiometer (MODIS aboard Aqua are available for two of the over-water flights and are shown to agree with AATS AODs to within root mean square (RMS differences of 0.00–0.06, depending on wavelength. Near-coincident ground-based AOD measurements from ground-based sun/sky radiometers operated as part of the Aerosol Robotic Network (AERONET

  14. Spatio-temporal distribution of absorbing and non-absorbing aerosols derived from Aura-OMI Aerosol Index over Greece

    Science.gov (United States)

    Kaskaoutis, D. G.; Nastos, P. T.; Kosmopoulos, P. G.; Kambezidis, H. D.; Kharol, S. K.; Badarinath, K. V. S.

    2009-04-01

    The Aerosol Index (AI) observations derived from the Ozone Monitoring Instrument (OMI) on board the Dutch-Finnish Aura satellite are analyzed over Greece covering the whole period of the OMI available data, from September 2004 to August 2008. The objective of this study was to analyze the spatial, seasonal and inter-annual variability of AI over Greece, detected by OMI during 2004-2008, with an evaluation of potential contributing factors, including precipitation and long-range transport (Sahara dust and European pollution). The AI data cover the whole Greek territory (34o-42oN, 20o-28oE) with a spatial resolution of 0.25o x 0.25o (13 km x 24 km at nadir). The results show significant spatial and temporal variability of the seasonal and monthly mean AI, with higher values at the southern parts and lower values over northern Greece. On the other hand, the AI values do not show significant differences between the western and eastern parts and, therefore, the longitude-averaged AI values can be utilized to reveal the strong south-to-north gradient. This gradient significantly changes from season to season being more intense in spring and summer, while it is minimized in winter. Another significant remark is the dominance of negative AI values over northern Greece in the summer months, indicating the presence of non-UV absorbing aerosols, such as sulfate and sea-salt particles. The great geographical extent of the negative AI values in the summer months is indicative of long-range transport of such aerosols. In contrast, the high positive AI values over south Greece, mainly in spring, clearly reveal the UV-absorbing nature of desert-dust particles affecting the area during Saharan dust events. Synoptically, the spatial distribution in OMI-AI values was related to the Saharan dust events mainly over southern Greece and to the trans-boundary-pollution transport, consisting mainly of sulfate particles, in northern Greece. The annual variation of spatial-averaged AI values

  15. Interpretation of Aura satellite observations of CO and aerosol index related to the December 2006 Australia fires

    Science.gov (United States)

    Luo, M.; Boxe, C.; Jiang, J.; Nassar, R.; Livesey, N.

    2009-11-01

    Enhanced Carbon Monoxide (CO) in the upper troposphere (UT) is shown by collocated Tropospheric Emission Spectrometer (TES) and Microwave Limb Sounder (MLS) measurements near and down-wind from the known wildfire region of SE Australia from 12-19 December 2006. Enhanced UV aerosol index (AI) derived from Ozone Monitoring Instrument (OMI) measurements correlate with these high CO concentrations. HYSPLIT model back trajectories trace selected air parcels to the SE Australia fire region as their initial location, where TES observes enhanced CO in the upper and lower troposphere. Simultaneously, they show a lack of vertical advection along their tracks. TES retrieved CO vertical profiles in the higher and lower southern latitudes are examined together with the averaging kernels and show that TES CO retrievals are most sensitive at approximately 300-400 hPa. The enhanced CO observed by TES at the upper (215 hPa) and lower (681 hPa) troposphere are, therefore, influenced by mid-tropospheric CO. GEOS-Chem model simulations with an 8-day emission inventory, as the wildfire source over Australia, are sampled to the TES/MLS observation times and locations. These simulations only show CO enhancements in the lower troposphere near and down-wind from the wildfire region of SE Australia with drastic underestimates of UT CO. Although CloudSat along-track ice-water content curtains are examined to see whether possible vertical convection events can explain the high UT CO values, sparse observations of collocated Aura CO and CloudSat along-track ice-water content measurements for the single event precludes any conclusive correlation. Vertical convection that uplift fire-induced CO (i.e. most notably referred to as pyro-cumulonimbus, pyroCb) may provide an explanation for the incongruence between these simulations and the TES/MLS observations of enhanced CO in the UT. Future GEOS-Chem simulations are needed to validate this conjecture as the the PyroCb mechanism is currently not

  16. Perfusion-weighted MR imaging in persistent hemiplegic migraine

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Menjot de Champfleur, Nicolas; Carra-Dalliere, Clarisse; Le Bars, Emmanuelle; Bonafe, Alain; Thouvenot, Eric; Roubertie, Agathe

    2012-01-01

    Hemiplegic migraine is a rare type of migraine that has an aura characterized by the presence of motor weakness, which may occasionally last up to several days, and then resolve without sequela. Pathogenesis of migraine remains unclear and, recently, perfusion-weighted imaging (PWI) has provided a non-invasive method to study hemodynamic changes during acute attacks. Two female patients were admitted in our hospital suffering from prolonged hemiparesis. In both cases, they underwent MRI examination using a 1.5 T magnet including axial diffusion-weighted and perfusion sequences. From each perfusion MRI acquisition two regions of interest were delineated on each hemisphere and, the index of flow, cerebral blood volume, mean transit time, and time to peak were recorded and asymmetry indices from each perfusion parameter were calculated. Perfusion alterations were detected during the attacks. In one case, we observed, after 3 h of left hemiparesia, hypoperfusion of the right hemisphere. In the other case, who presented a familial hemiplegic migraine attack, on the third day of a persistent aura consisting of right hemiplegia and aphasia, PWI revealed hyperperfusion of the left hemisphere. Asymmetry indices for temporal parameters (mean transit time and time to peak) were the most sensitive. These findings resolved spontaneously after the attacks without any permanent sequel or signs of cerebral ischemia on follow-up MRI. PWI should be indicated for patients with migraine attacks accompanied by auras to assess the sequential changes in cerebral perfusion and to better understand its pathogenesis. (orig.)

  17. Perfusion-weighted MR imaging in persistent hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle; Menjot de Champfleur, Nicolas; Carra-Dalliere, Clarisse; Le Bars, Emmanuelle; Bonafe, Alain; Thouvenot, Eric [Hopital Gui de Chauliac, Service de Neuroradiologie, Montpellier (France); Roubertie, Agathe [Hopital Gui de Chauliac, Service de Neuropediatrie, Montpellier (France)

    2012-03-15

    Hemiplegic migraine is a rare type of migraine that has an aura characterized by the presence of motor weakness, which may occasionally last up to several days, and then resolve without sequela. Pathogenesis of migraine remains unclear and, recently, perfusion-weighted imaging (PWI) has provided a non-invasive method to study hemodynamic changes during acute attacks. Two female patients were admitted in our hospital suffering from prolonged hemiparesis. In both cases, they underwent MRI examination using a 1.5 T magnet including axial diffusion-weighted and perfusion sequences. From each perfusion MRI acquisition two regions of interest were delineated on each hemisphere and, the index of flow, cerebral blood volume, mean transit time, and time to peak were recorded and asymmetry indices from each perfusion parameter were calculated. Perfusion alterations were detected during the attacks. In one case, we observed, after 3 h of left hemiparesia, hypoperfusion of the right hemisphere. In the other case, who presented a familial hemiplegic migraine attack, on the third day of a persistent aura consisting of right hemiplegia and aphasia, PWI revealed hyperperfusion of the left hemisphere. Asymmetry indices for temporal parameters (mean transit time and time to peak) were the most sensitive. These findings resolved spontaneously after the attacks without any permanent sequel or signs of cerebral ischemia on follow-up MRI. PWI should be indicated for patients with migraine attacks accompanied by auras to assess the sequential changes in cerebral perfusion and to better understand its pathogenesis. (orig.)

  18. OMI/Aura Multi-wavelength Aerosol Optical Depth and Single Scattering Albedo Daily L2 Global 0.25x0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The second release of Collection 3 OMI/Aura level-2G daily global gridded (0.25x0.25 deg) Aerosol data product OMAEROG (Version 003 has been made available to the...

  19. OMI/Aura Near UV Aerosol Optical Depth and Single Scattering Albedo Daily L2 Global 0.25x0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The OMI-Aura level-2G daily global gridded (0.25x0.25 deg) near-UV Aerosol data product OMAERUVG based on the enhanced algorithm is available from the NASA Goddard...

  20. Mudança no padrão biológico da migrânea com aura após a utilização da tetrabenazina: relato de caso Change in the biologic pattern of the migraine with aura after the use of tetrabenazine: case report

    Directory of Open Access Journals (Sweden)

    ELCIO JULIATO PIOVESAN

    2000-06-01

    Full Text Available A participação do sistema dopaminérgico na fisiopatologia da migrânea tem sido proposta a partir de recentes conquistas genéticas. Uma possível hipereatividade dos receptores dopaminérgicos DRD2 tornou as evidências mais contundentes neste sentido. Descrevemos paciente masculino, 31 anos, portador de distonia generalizada, secundária a hipóxia perinatal. Aos 16 anos, começou a ter crises de cefaléia que preenchiam os critérios para migrânea com aura. Três anos após tratamento da distônia com tetrabenazina, observou-se nítida redução da frequência, intensidade e duração das crises. Durante dois períodos, superiores a dois meses, a interrupção do tratamento com tetrabenazina induziu piora nas crises de migrânea. Apresentamos este relato como sendo a primeira descrição na literatura mostrando efeitos benéficos da tetrabenazina, um bloqueador dos receptores dopaminérgicos, sobre o comportamento da migrânea com aura.The influence of the dopaminergic system on the pathophysiology of migraine has been suggested as a result of recent genetic discoveries. A possible hyper-reactivity of the dopaminergic receptors DRD2 reinforced the evidence regarding this. We describe a 31 years-old male patient affected by a generalized dystonia secondary to perinatal hypoxia. At age 16, the patient started having headache crises that met the criteria for migraine with aura. After three years of treatment for dystonia with tetrabenazine, a clear reduction in the frequency, intensity and duration of the crises was perceived. During two periods longer than two months, the interruption of the treatment with tetrabenazine brought about an aggravation of the migraine crises. We present this case as being the first description in the literature showing the beneficial effects of tetrabenazine, a blocker of dopaminergic receptors, on the behavior of migraine with aura.

  1. A comprehensive overview of the climatological composition of the Asian summer monsoon anticyclone based on 10 years of Aura Microwave Limb Sounder measurements

    Science.gov (United States)

    Santee, M. L.; Manney, G. L.; Livesey, N. J.; Schwartz, M. J.; Neu, J. L.; Read, W. G.

    2017-05-01

    Intense deep convection associated with the Asian summer monsoon (ASM) lofts surface pollutants to the upper troposphere/lower stratosphere (UTLS), where strong winds and long chemical lifetimes allow intercontinental transport, affecting atmospheric composition around the globe. The Aura Microwave Limb Sounder (MLS), launched in 2004, makes simultaneous colocated measurements of trace gases and cloud ice water content (a proxy for deep convection) in the UTLS on a daily basis. Here we exploit the dense spatial and temporal coverage, long-term data record, extensive measurement suite, and insensitivity to aerosol and most clouds of Aura MLS to characterize the climatological (2005-2014) composition of the ASM anticyclone throughout its annual life cycle. We use version 4 MLS data to quantify spatial and temporal variations in both tropospheric (H2O, CO, CH3Cl, CH3CN, CH3OH) and stratospheric (O3, HNO3, HCl) tracers on four potential temperature surfaces (350-410 K). Inside the mature anticyclone, all species exhibit substantial changes, not only from their premonsoon distributions in the ASM region but also from their summertime distributions in the rest of the hemisphere. Different tracers exhibit dissimilar seasonal evolution, and the exact location and timing of their extreme values vary. Although individual aspects of the anticyclone have been described previously, we present a uniquely comprehensive overview of the climatological seasonal evolution of the ASM and its impact on UTLS composition. This work provides valuable context for planned in situ measurements as well as a benchmark for model evaluation and future investigations of interannual variability and long-term changes in monsoon processes.

  2. Acupuncture therapy in treating migraine: results of a magnetic resonance spectroscopy imaging study.

    Science.gov (United States)

    Gu, Tao; Lin, Lei; Jiang, Yun; Chen, Juan; D'Arcy, Ryan Cn; Chen, Min; Song, Xiaowei

    2018-01-01

    Acupuncture has been proven to be effective as an alternative therapy in treating migraine, but the pathophysiological mechanisms of the treatment remain unclear. This study investigated possible neurochemical responses to acupuncture treatment. Proton magnetic resonance spectroscopy imaging was used to investigate biochemical levels pre- and post-acupuncture treatment. Participants (N=45) included subjects diagnosed with: 1) migraine without aura; 2) cervicogenic headache; and 3) healthy controls. Participants in the two patient groups received verum acupuncture using acupoints that target migraine without aura but not cervicogenic headache, while the healthy controls received a sham treatment. All participants had magnetic resonance spectroscopy scans before and after the acupuncture therapy. Levels of brain metabolites were examined in relation to clinical headache assessment scores. A significant increase in N -acetylaspartate/creatine was observed in bilateral thalamus in migraine without aura after the acupuncture treatment, which was significantly correlated with the headache intensity score. The data demonstrate brain biochemical changes underlying the effect of acupuncture treatment of migraine.

  3. Featured Image: Revealing Hidden Objects with Color

    Science.gov (United States)

    Kohler, Susanna

    2018-02-01

    Stunning color astronomical images can often be the motivation for astronomers to continue slogging through countless data files, calculations, and simulations as we seek to understand the mysteries of the universe. But sometimes the stunning images can, themselves, be the source of scientific discovery. This is the case with the below image of Lynds Dark Nebula 673, located in the Aquila constellation, that was captured with the Mayall 4-meter telescope at Kitt Peak National Observatory by a team of scientists led by Travis Rector (University of Alaska Anchorage). After creating the image with a novel color-composite imaging method that reveals faint H emission (visible in red in both images here), Rector and collaborators identified the presence of a dozen new Herbig-Haro objects small cloud patches that are caused when material is energetically flung out from newly born stars. The image adapted above shows three of the new objects, HH 118789, aligned with two previously known objects, HH 32 and 332 suggesting they are driven by the same source. For more beautiful images and insight into the authors discoveries, check out the article linked below!Full view of Lynds Dark Nebula 673. Click for the larger view this beautiful composite image deserves! [T.A. Rector (University of Alaska Anchorage) and H. Schweiker (WIYN and NOAO/AURA/NSF)]CitationT. A. Rector et al 2018 ApJ 852 13. doi:10.3847/1538-4357/aa9ce1

  4. Effets de présence, délocalisations et relocalisations des images : le médium en quête d’espace ?

    Directory of Open Access Journals (Sweden)

    Benjamin Philippe Léon

    2014-07-01

    Full Text Available Retour sur la “XII MAGIS - Gorizia International Film Studies Spring School”, qui aura permis durant une semaine d’élaborer une somme de réflexions autour des images à l’heure du contemporain. Une conférence aux réflexions stimulantes et stimulées par l’approche plurielle du “FilmForum”.

  5. Screening LGI1 in a cohort of 26 lateral temporal lobe epilepsy patients with auditory aura from Turkey detects a novel de novo mutation.

    Science.gov (United States)

    Kesim, Yesim F; Uzun, Gunes Altiokka; Yucesan, Emrah; Tuncer, Feyza N; Ozdemir, Ozkan; Bebek, Nerses; Ozbek, Ugur; Iseri, Sibel A Ugur; Baykan, Betul

    2016-02-01

    Autosomal dominant lateral temporal lobe epilepsy (ADLTE) is an autosomal dominant epileptic syndrome characterized by focal seizures with auditory or aphasic symptoms. The same phenotype is also observed in a sporadic form of lateral temporal lobe epilepsy (LTLE), namely idiopathic partial epilepsy with auditory features (IPEAF). Heterozygous mutations in LGI1 account for up to 50% of ADLTE families and only rarely observed in IPEAF cases. In this study, we analysed a cohort of 26 individuals with LTLE diagnosed according to the following criteria: focal epilepsy with auditory aura and absence of cerebral lesions on brain MRI. All patients underwent clinical, neuroradiological and electroencephalography examinations and afterwards they were screened for mutations in LGI1 gene. The single LGI1 mutation identified in this study is a novel missense variant (NM_005097.2: c.1013T>C; p.Phe338Ser) observed de novo in a sporadic patient. This is the first study involving clinical analysis of a LTLE cohort from Turkey and genetic contribution of LGI1 to ADLTE phenotype. Identification of rare LGI1 gene mutations in sporadic cases supports diagnosis as ADTLE and draws attention to potential familial clustering of ADTLE in suggestive generations, which is especially important for genetic counselling. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Improvement of the image quality of a high-temperature vision system

    International Nuclear Information System (INIS)

    Fabijańska, Anna; Sankowski, Dominik

    2009-01-01

    In this paper, the issues of controlling and improving the image quality of a high-temperature vision system are considered. The image quality improvement is needed to measure the surface properties of metals and alloys. Two levels of image quality control and improvement are defined in the system. The first level in hardware aims at adjusting the system configuration to obtain the highest contrast and weakest aura images. When optimal configuration is obtained, the second level in software is applied. In this stage, image enhancement algorithms are applied which have been developed with consideration of distortions arising from the vision system components and specificity of images acquired during the measurement process. The developed algorithms have been applied in the vision system to images. The influence on the accuracy of wetting angles and surface tension determination are considered

  7. Image, Image, Image

    Science.gov (United States)

    Howell, Robert T.

    2004-01-01

    With all the talk today about accountability, budget cuts, and the closing of programs in public education, teachers cannot overlook the importance of image in the field of industrial technology. It is very easy for administrators to cut ITE (industrial technology education) programs to save school money--money they might shift to teaching the…

  8. Fine-scale assessment of home ranges and activity patterns for resident black vultures (Coragyps atratus and turkey vultures (Cathartes aura.

    Directory of Open Access Journals (Sweden)

    Amanda E Holland

    Full Text Available Knowledge of black vulture (Coragyps atratus and turkey vulture (Cathartes aura spatial ecology is surprisingly limited despite their vital ecological roles. Fine-scale assessments of space use patterns and resource selection are particularly lacking, although development of tracking technologies has allowed data collection at finer temporal and spatial resolution. Objectives of this study were to conduct the first assessment of monthly home range and core area sizes of resident black and turkey vultures with consideration to sex, as well as elucidate differences in monthly, seasonal, and annual activity patterns based on fine-scale movement data analyses. We collected 2.8-million locations for 9 black and 9 turkey vultures from June 2013 -August 2015 using solar-powered GSM/GPS transmitters. We quantified home ranges and core areas using the dynamic Brownian bridge movement model and evaluated differences as a function of species, sex, and month. Mean monthly home ranges for turkey vultures were ~50% larger than those of black vultures, although mean core area sizes did not differ between species. Turkey vulture home ranges varied little across months, with exception to a notable reduction in space-use in May, which corresponds with timing of chick-rearing activities. Black vulture home ranges and core areas as well as turkey vulture core areas were larger in breeding season months (January-April. Comparison of space use between male and female vultures was only possible for black vultures, and space use was only slightly larger for females during breeding months (February-May. Analysis of activity patterns revealed turkey vultures spend more time in flight and switch motion states (between flight and stationary more frequently than black vultures across temporal scales. This study reveals substantive variability in space use and activity rates between sympatric black and turkey vultures, providing insights into potential behavioral mechanisms

  9. Comparison of frovatriptan plus dexketoprofen (25 mg or 37.5 mg) with frovatriptan alone in the treatment of migraine attacks with or without aura: a randomized study.

    Science.gov (United States)

    Tullo, Vincenzo; Valguarnera, Fabio; Barbanti, Piero; Cortelli, Pietro; Sette, Giuliano; Allais, Gianni; d'Onofrio, Florindo; Curone, Marcella; Zava, Dario; Pezzola, Deborha; Benedetto, Chiara; Frediani, Fabio; Bussone, Gennaro

    2014-05-01

    Drugs for migraine attacks include triptans and NSAIDs; their combination could provide greater symptom relief. A total of 314 subjects with history of migraine, with or without aura, were randomized to frovatriptan 2.5 mg alone (Frova), frovatriptan 2.5 mg + dexketoprofen 25 mg (FroDex25) or frovatriptan 2.5 mg + dexketoprofen 37.5 mg (FroDex37.5) and treated at least one migraine attack. This was a multicenter, randomized, double-blind, parallel-group study. The primary end point was the proportion of pain free (PF) at two hours. Secondary end points were PF at one and four hours, pain relief (PR) at one, two, four hours, sustained PF (SPF) at 24 and 48 hours, recurrence at 48 hours, resolution of nausea, photophobia and phonophobia at two and four hours, the use of rescue medication and the judgment of the treatment. The results were assessed in the full analysis set (FAS) population, which included all subjects randomized and treated for whom at least one post-dose intensity of headache was recorded. The proportions of subjects PF at two hours (primary end point) were 29% (27/93) with Frova compared with 51% (48/95 FroDex25 and 46/91 FroDex37.5) with each combination therapies ( P dexketoprofen. FroDex improved initial efficacy at two hours compared to Frova whilst maintaining efficacy at 48 hours in this study. Tolerability profiles were comparable. Intrinsic pharmacokinetic properties of the two single drugs contribute to this improved efficacy profile.

  10. High Precision, Absolute Total Column Ozone Measurements from the Pandora Spectrometer System: Comparisons with Data from a Brewer Double Monochromator and Aura OMI

    Science.gov (United States)

    Tzortziou, Maria A.; Herman, Jay R.; Cede, Alexander; Abuhassan, Nader

    2012-01-01

    We present new, high precision, high temporal resolution measurements of total column ozone (TCO) amounts derived from ground-based direct-sun irradiance measurements using our recently deployed Pandora single-grating spectrometers. Pandora's small size and portability allow deployment at multiple sites within an urban air-shed and development of a ground-based monitoring network for studying small-scale atmospheric dynamics, spatial heterogeneities in trace gas distribution, local pollution conditions, photochemical processes and interdependencies of ozone and its major precursors. Results are shown for four mid- to high-latitude sites where different Pandora instruments were used. Comparisons with a well calibrated double-grating Brewer spectrometer over a period of more than a year in Greenbelt MD showed excellent agreement and a small bias of approximately 2 DU (or, 0.6%). This was constant with slant column ozone amount over the full range of observed solar zenith angles (15-80), indicating adequate Pandora stray light correction. A small (1-2%) seasonal difference was found, consistent with sensitivity studies showing that the Pandora spectral fitting TCO retrieval has a temperature dependence of 1% per 3K, with an underestimation in temperature (e.g., during summer) resulting in an underestimation of TCO. Pandora agreed well with Aura-OMI (Ozone Measuring Instrument) satellite data, with average residuals of <1% at the different sites when the OMI view was within 50 km from the Pandora location and OMI-measured cloud fraction was <0.2. The frequent and continuous measurements by Pandora revealed significant short-term (hourly) temporal changes in TCO, not possible to capture by sun-synchronous satellites, such as OMI, alone.

  11. Interrelated variations of O3, CO and deep convection in the tropical/subtropical upper troposphere observed by the Aura Microwave Limb Sounder (MLS during 2004–2011

    Directory of Open Access Journals (Sweden)

    L. Froidevaux

    2013-01-01

    Full Text Available The interrelated geographic and temporal variability seen in more than seven years of tropical and subtropical upper tropospheric (215 hPa ozone, carbon monoxide and cloud ice water content (IWC observations by the Aura Microwave Limb Sounder (MLS are presented. Observed ozone abundances and their variability (geographic and temporal agree to within 10–15 ppbv with records from sonde observations. MLS complements these (and other observations with global coverage and simultaneous measurements of related parameters. Previously-reported phenomena such as the ozone "wave one" feature are clearly seen in the MLS observations, as is a double peak in ozone abundance over tropical East Africa, with enhanced abundances in both May to June and September to November. While repeatable seasonal cycles are seen in many regions, they are often accompanied by significant interannual variability. Ozone seasonal cycles in the southern tropics and subtropics tend to be more distinct (i.e., annually repeatable than in the northern. By contrast, carbon monoxide shows distinct seasonal cycles in many northern subtropical regions, notably from India to the Eastern Pacific. Deep convection (as indicated by large values of IWC is typically associated with reductions in upper tropospheric ozone. Convection over polluted regions is seen to significantly enhance upper tropospheric carbon monoxide. While some regions show statistically significant correlations among ozone, carbon monoxide and IWC, simple correlations fall well short of accounting for the observed variability. The observed interrelated variations and metrics of annual and interannual variability described here represent a new resource for validation of atmospheric chemistry models.

  12. Images of Turks in the Works of Lawrence Durrell

    Directory of Open Access Journals (Sweden)

    Ahmet Kayıntu

    2011-12-01

    Full Text Available This study seeks to explore the images of Turks as a non-European other in the works of Lawrence Durrell. In his works, Durrell shows how representations of cultural difference are inextricably linked to representations of sexual difference. Thus Durrell‟s Europeans are surrounded with an aura of colonial power, erotic potency, and easy penetration into the spaces of the other while Turks are represented as feminized, emasculated and humiliated. The images of the European White man and non- are dependent on the negative image of Turks, the other. In exactly the same way, Istanbul is presented as a city of decadence and decay, a place where decent human values broken down and where individuals survive by their wits ability to dodge or swindle

  13. Assessment of the rate of premolar extraction space closure in the maxillary arch with the AcceleDent Aura appliance vs no appliance in adolescents: A single-blind randomized clinical trial.

    Science.gov (United States)

    Miles, Peter; Fisher, Elizabeth; Pandis, Nikolaos

    2018-01-01

    The purpose of this 2-arm parallel trial was to assess the effect of the AcceleDent Aura appliance (OrthoAccel Technologies, Houston, Tex) on the rate of maxillary premolar extraction space closure in adolescent patients. Forty Class II adolescents treated with full fixed appliances and maxillary premolar extractions participated in this randomized clinical trial. They were recruited in a private practice and treated by 1 clinician. Randomization was accomplished in blocks of 10 patients assigned to either a no-appliance group or the AcceleDent Aura appliance group with the allocations concealed in opaque, sealed envelopes. Both the operator and the outcome assessor were blinded; however, it was not feasible to blind the patients. Models were taken of the maxillary arch at the start of space closure and just before complete space closure. The space was measured parallel to the occlusal plane from the cusp tips of the teeth mesial and distal to the extraction spaces. There was no clinically (0.05 mm per month; 95% confidence interval [CI], -0.24, 0.34) or statistically significant difference in the rate of space closure (P = 0.74). In both the univariable and multivariable analyses, the mean rate of tooth movement was slower by 0.13 mm per month (95% CI, -.26, .005) on the left side compared with the right side, but this was not statistically significant (P = 0.06). The AcceleDent Aura appliance had no effect on the rate of maxillary premolar extraction space closure. Only a few participants were considered to be good compliers with the appliance. However, the rate of space closure in the good compliers was similar to the overall group and did not appear to influence the result. This trial was not registered. The protocol was not published before trial commencement. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  14. Comparison of CMAM simulations of carbon monoxide (CO, nitrous oxide (N2O, and methane (CH4 with observations from Odin/SMR, ACE-FTS, and Aura/MLS

    Directory of Open Access Journals (Sweden)

    B. Barret

    2009-05-01

    Full Text Available Simulations of CO, N2O and CH4 from a coupled chemistry-climate model (CMAM are compared with satellite measurements from Odin Sub-Millimeter Radiometer (Odin/SMR, Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS, and Aura Microwave Limb Sounder (Aura/MLS. Pressure-latitude cross-sections and seasonal time series demonstrate that CMAM reproduces the observed global CO, N2O, and CH4 distributions quite well. Generally, excellent agreement with measurements is found between CO simulations and observations in the stratosphere and mesosphere. Differences between the simulations and the ACE-FTS observations are generally within 30%, and the differences between CMAM results and SMR and MLS observations are slightly larger. These differences are comparable with the difference between the instruments in the upper stratosphere and mesosphere. Comparisons of N2O show that CMAM results are usually within 15% of the measurements in the lower and middle stratosphere, and the observations are close to each other. However, the standard version of CMAM has a low N2O bias in the upper stratosphere. The CMAM CH4 distribution also reproduces the observations in the lower stratosphere, but has a similar but smaller negative bias in the upper stratosphere. The negative bias may be due to that the gravity drag is not fully resolved in the model. The simulated polar CO evolution in the Arctic and Antarctic agrees with the ACE and MLS observations. CO measurements from 2006 show evidence of enhanced descent of air from the mesosphere into the stratosphere in the Arctic after strong stratospheric sudden warmings (SSWs. CMAM also shows strong descent of air after SSWs. In the tropics, CMAM captures the annual oscillation in the lower stratosphere and the semiannual oscillations at the stratopause and mesopause seen in Aura/MLS CO and N2O observations and in Odin/SMR N2O observations. The Odin/SMR and Aura/MLS N2O observations also show a quasi

  15. Comparison of UV irradiances from Aura/Ozone Monitoring Instrument (OMI with Brewer measurements at El Arenosillo (Spain – Part 1: Analysis of parameter influence

    Directory of Open Access Journals (Sweden)

    M. Antón

    2010-07-01

    Full Text Available The main objective of this study is to compare the erythemal UV irradiance (UVER and spectral UV irradiances (at 305, 310 and 324 nm from the Ozone Monitoring Instrument (OMI onboard NASA EOS/Aura polar sun-synchronous satellite (launched in July 2004, local equator crossing time 01:45 p.m. with ground-based measurements from the Brewer spectrophotometer #150 located at El Arenosillo (South of Spain. The analyzed period comprises more than four years, from October 2004 to December 2008. The effects of several factors (clouds, aerosols and the solar elevation on OMI-Brewer comparisons were analyzed. The proxies used for each factor were: OMI Lambertian Equivalent Reflectivity (LER at 360 nm (clouds, the aerosol optical depth (AOD at 440 nm measured from the ground-based Cimel sun-photometer (http://aeronet.gsfc.nasa.gov, and solar zenith angle (SZA at OMI overpass time. The comparison for all sky conditions reveals positive biases (OMI higher than Brewer 12.3% for UVER, 14.2% for UV irradiance at 305 nm, 10.6% for 310 nm and 8.7% for 324 nm. The OMI-Brewer root mean square error (RMSE is reduced when cloudy cases are removed from the analysis, (e.g., RMSE~20% for all sky conditions and RMSE smaller than 10% for cloud-free conditions. However, the biases remain and even become more significant for the cloud-free cases with respect to all sky conditions. The mentioned overestimation is partially due to aerosol extinction influence. In addition, the differences OMI-Brewer typically decrease with SZA except days with high aerosol loading, when the bias is near constant. The seasonal dependence of the OMI-Brewer difference for cloud-free conditions is driven by aerosol climatology.

    To account for the aerosol effect, a first evaluation in order to compare with previous TOMS results (Antón et al., 2007 was performed. This comparison shows that the OMI bias is between +14% and +19% for

  16. The power features of Masseter muscle activity in tension-type and migraine without aura headache during open-close clench cycles

    Directory of Open Access Journals (Sweden)

    Behrouz Alizadeh Savareh

    2017-07-01

    Full Text Available Introduction Different types of headaches and TMJ click influence the masseter muscle activity. The aim of this study was to assess the trend of energy level of the electromyography (EMG activity of the masseter muscle during open-close clench cycles in migraine without aura (MOA and tension-type headache (TTH with or without TMJ click. Methods Twenty-five women with MOA and twenty four women with TTH participated in the study. They matched with 25 healthy subjects, in terms of class of occlusion and prevalence of temporomandibular joint (TMJ with click. The EMG of both masseter muscles were recorded during open-close clench cycles at a rate of 80 cycles per minute for 15 seconds. The mouth opening was restricted to two centimeters by mandibular motion frame. Signal processing steps have been done on the EMG as: noise removing, smoothing, feature extraction, and statistical analyzing. The six statistical parameters of energy computed were mean, Variance, Skewness, Kurtosis, and first and second half energy over all signal energy. Results A three-way ANOVA indicated that during all the cycles, the mean of energy was more and there was a delay in showing the peak of energy in the masseter of the left side with clicked TMJ in MOA group compared to the two other groups, while this pattern occurred inversely in the side with no-clicked TMJ (P < 0.009. The variation of energy was significantly less in MOA group compared to the two other groups in the no-clicked TMJ (P < 0.003. However, the proportion of the first or second part of signal energy to all energy showed that TTH group had less energy in the first part and more energy in the second part in comparison to the two other groups (P < 0.05. Conclusion The study showed different changes in the energy distribution of masseter muscle activity during cycles in MOA and TTH. MOA, in contrast to TTH, had lateralization effect on EMG and interacted with TMJ click.

  17. Benchmarking CCMI models' top-of-atmosphere flux in the 9.6-µm ozone band using AURA TES Instantaneous Radiative Kernel

    Science.gov (United States)

    Kuai, L.; Bowman, K. W.; Worden, H. M.; Paulot, F.; Paynter, D.; Oman, L.; Strode, S. A.; Rozanov, E.; Stenke, A.; Revell, L. E.; Plummer, D. A.

    2017-12-01

    The estimated ozone radiative forcing (RF) from chemical-climate models range widely from +0.2 to +0.6 Wm-2. The reason has never been well understood. Since the ozone absorption in the 9.6 μm band contributes 97% of the O3 longwave RF, the variation of outgoing longwave radiation (OLR) due to ozone is dominant by this band. The observed TOA flux over 9.6 µm ozone band by Thermal Emission Spectrometer (TES) shows the global distribution has unique spatial patterns. In addition, the simulated TOA fluxes over 9.6 µm ozone band by different models have never been evaluated against observations. The bias of TOA flux from model could be primarily contributed by the bias of temperature, water vapor and ozone. Furthermore, the sensitivity of TOA flux to tropospheric ozone (instantaneous radiative kernel, IRK) may also affected by these biases (Kuai et al., 2017). The bias in TOA flux would eventually propagate into model calculations of ozone RF and cause divergence of the predictions of future climate by models. In this study, we applied the observation-based IRK product by AURA TES to attribute the CCMI model bias in TOA flux over 9.6 µm ozone band to ozone, water vapor, air temperature, and surface temperature. The comparisons of the three CCMI models (AM3, SOCOL3 and GEOCCM) to TES observations suggest that 1) all models underestimate the TOA flux at tropics and subtropics. 2) The TOA flux bias is comparable similar by AM3 and GEOSCC (-0.2 to -0.3 W/m2) however is larger for the relative young model, SOCOL3 (-0.4 to -0.6 W/m2). 3) The contributions by surface temperature are similarly moderate (-0.2 W/m2). 4) The contribution of ozone is largest by SOCOL3 (-0.3 W/m2), smallest by GEOSCCM (less than 0.1 W/m2) and moderate by AM3 (-0.2 W/m2). 5) Overall, the contributions by atmospheric temperature are all small (less than 0.1 W/m2). 6) The contribution of water vapor is negative and small by both SOCOL3 and GEOSCCM (0.1 W/m2) however large and positive by AM3 (0

  18. Vertical and interhemispheric links in the stratosphere-mesosphere as revealed by the day-to-day variability of Aura-MLS temperature data

    Directory of Open Access Journals (Sweden)

    X. Xu

    2009-09-01

    Full Text Available The coupling processes in the middle atmosphere have been a subject of intense research activity because of their effects on atmospheric circulation, structure, variability, and the distribution of chemical constituents. In this study, the day-to-day variability of Aura-MLS (Microwave Limb Sounder temperature data are used to reveal the vertical and interhemispheric coupling processes in the stratosphere-mesosphere during four Northern Hemisphere winters (2004/2005–2007/2008. The UKMO (United Kingdom Meteorological Office assimilated data and mesospheric winds from MF (medium frequency radars are also applied to help highlight the coupling processes.

    In this study, a clear vertical link can be seen between the stratosphere and mesosphere during winter months. The coolings and reversals of northward meridional winds in the polar winter mesosphere are often observed in relation to warming events (Sudden Stratospheric Warming, SSW for short and the associated changes in zonal winds in the polar winter stratosphere. An upper-mesospheric cooling usually precedes the beginning of the warming in the stratosphere by 1–2 days.

    Inter-hemispheric coupling has been identified initially by a correlation analysis using the year-to-year monthly zonal mean temperature. Then the correlation analyses are performed based upon the daily zonal mean temperature. From the original time sequences, significant positive (negative correlations are generally found between zonal mean temperatures at the Antarctic summer mesopause and in the Arctic winter stratosphere (mesosphere during northern mid-winters, although these correlations are dominated by the low frequency variability (i.e. the seasonal trend. Using the short-term oscillations (less than 15 days, the statistical result, by looking for the largest magnitude of correlation within a range of time-lags (0 to 10 days; positive lags mean that the Antarctic summer mesopause is lagging, indicates

  19. Vertical and interhemispheric links in the stratosphere-mesosphere as revealed by the day-to-day variability of Aura-MLS temperature data

    Directory of Open Access Journals (Sweden)

    X. Xu

    2009-09-01

    Full Text Available The coupling processes in the middle atmosphere have been a subject of intense research activity because of their effects on atmospheric circulation, structure, variability, and the distribution of chemical constituents. In this study, the day-to-day variability of Aura-MLS (Microwave Limb Sounder temperature data are used to reveal the vertical and interhemispheric coupling processes in the stratosphere-mesosphere during four Northern Hemisphere winters (2004/2005–2007/2008. The UKMO (United Kingdom Meteorological Office assimilated data and mesospheric winds from MF (medium frequency radars are also applied to help highlight the coupling processes. In this study, a clear vertical link can be seen between the stratosphere and mesosphere during winter months. The coolings and reversals of northward meridional winds in the polar winter mesosphere are often observed in relation to warming events (Sudden Stratospheric Warming, SSW for short and the associated changes in zonal winds in the polar winter stratosphere. An upper-mesospheric cooling usually precedes the beginning of the warming in the stratosphere by 1–2 days. Inter-hemispheric coupling has been identified initially by a correlation analysis using the year-to-year monthly zonal mean temperature. Then the correlation analyses are performed based upon the daily zonal mean temperature. From the original time sequences, significant positive (negative correlations are generally found between zonal mean temperatures at the Antarctic summer mesopause and in the Arctic winter stratosphere (mesosphere during northern mid-winters, although these correlations are dominated by the low frequency variability (i.e. the seasonal trend. Using the short-term oscillations (less than 15 days, the statistical result, by looking for the largest magnitude of correlation within a range of time-lags (0 to 10 days; positive lags mean that the Antarctic summer mesopause is lagging, indicates that the temporal

  20. Image Gallery

    Science.gov (United States)

    ... R S T U V W X Y Z Image Gallery Share: The Image Gallery contains high-quality digital photographs available from ... Select a category below to view additional thumbnail images. Images are available for direct download in 2 ...

  1. Magnetic resonance imaging of the brain in patients with migraine

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, H.; Sakai, F.; Kan, S.; Okada, J.; Tazaki, Y. (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1991-05-01

    Magnetic resonance imaging (MRI) was studied in 91 patients with migraine and in 98 controls. Risk factors known to cause MRI lesions were carefully examined. In 36 patients with migraine (39.6%), small foci of high intensity on T{sub 2}-weighted and proton-density-weighted images were seen in the white matter. Of patients with migraine who were less than 40 years old and without any risk factor, 29.4% showed lesions on MRI; this was singificantly higher than the 11.2% for the group of age-matched controls (n=98). The lesions were distributed predominantly in the centrum semiovale and frontal white matter in young patients, but extended to the deeper white matter at the level of basal ganglia in the older age group. The side of the MRI lesions did not always correspond to the side of usual aura or headache. Migraine-related variables such as type of migraine, frequency, duration or intensity of headache or consumption of ergotamine showed no significant correlation with the incidence om MRI abnormalities. The data indicated that migraine may be associated with early pathologic changes in the brain. 26 refs., 4 figs., 3 tabs.

  2. Magnetic resonance imaging of the brain in patients with migraine

    International Nuclear Information System (INIS)

    Igarashi, H.; Sakai, F.; Kan, S.; Okada, J.; Tazaki, Y.

    1991-01-01

    Magnetic resonance imaging (MRI) was studied in 91 patients with migraine and in 98 controls. Risk factors known to cause MRI lesions were carefully examined. In 36 patients with migraine (39.6%), small foci of high intensity on T 2 -weighted and proton-density-weighted images were seen in the white matter. Of patients with migraine who were less than 40 years old and without any risk factor, 29.4% showed lesions on MRI; this was singificantly higher than the 11.2% for the group of age-matched controls (n=98). The lesions were distributed predominantly in the centrum semiovale and frontal white matter in young patients, but extended to the deeper white matter at the level of basal ganglia in the older age group. The side of the MRI lesions did not always correspond to the side of usual aura or headache. Migraine-related variables such as type of migraine, frequency, duration or intensity of headache or consumption of ergotamine showed no significant correlation with the incidence om MRI abnormalities. The data indicated that migraine may be associated with early pathologic changes in the brain. 26 refs., 4 figs., 3 tabs

  3. Image Statistics

    Energy Technology Data Exchange (ETDEWEB)

    Wendelberger, Laura Jean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-08

    In large datasets, it is time consuming or even impossible to pick out interesting images. Our proposed solution is to find statistics to quantify the information in each image and use those to identify and pick out images of interest.

  4. Image Guidance

    Science.gov (United States)

    Guidance that explains the process for getting images approved in One EPA Web microsites and resource directories. includes an appendix that shows examples of what makes some images better than others, how some images convey meaning more than others

  5. Data imaging

    International Nuclear Information System (INIS)

    Pepy, G.

    1999-01-01

    After an introduction about data imaging in general, the principles of imaging data collected via neutron scattering experiments are presented. Some computer programs designed for data imaging purposes are reviewed. (K.A.)

  6. Pancreatic imaging

    International Nuclear Information System (INIS)

    Potsaid, M.S.

    1978-01-01

    The clinical use of [ 75 Se] selenomethionine for visualising the pancreas is described. The physiological considerations, imaging procedure, image interpretations and reliability are considered. (C.F.)

  7. Parahippocampal epilepsy with subtle dysplasia: A cause of "imaging negative" partial epilepsy.

    Science.gov (United States)

    Pillay, Neelan; Fabinyi, Gavin C A; Myles, Terry S; Fitt, Gregory J; Berkovic, Samuel F; Jackson, Graeme D

    2009-12-01

    Lesion-negative refractory partial epilepsy is a major challenge in the assessment of patients for potential surgery. Finding a potential epileptogenic lesion simplifies assessment and is associated with good outcome. Here we describe imaging features of subtle parahippocampal dysplasia in five cases that were initially assessed as having imaging-negative frontal or temporal lobe epilepsy. We analyzed the clinical and imaging features of five patients with seizures from the parahippocampal region. Five patients had subtle but distinctive magnetic resonance imaging (MRI) abnormalities in the parahippocampal gyrus. This was a unilateral signal abnormality in the parahippocampal white matter extending into gray matter on heavily T(1)- and T(2)-weighted images with relative preservation of the gray-white matter boundary on T(1)-weighted volume sequences. Only one of these patients had typical electroclinical unilateral temporal lobe epilepsy (TLE); one mimicked frontal lobe epilepsy, two showed bitemporal seizures, and one had unlocalized partial seizures. All have had surgery; four are seizure-free (one has occasional auras only, follow-up 6 months to 10 years), and one has a >50% seizure reduction. Histopathologic evaluation suggested dysplastic features in the surgical specimens in all. In patients with lesion-negative partial epilepsy with frontal or temporal semiology, or in cases with apparent bitemporal seizures, subtle parahippocampal abnormalities should be carefully excluded. Recognizing the MRI findings of an abnormal parahippocampal gyrus can lead to successful surgery without invasive monitoring, despite apparently incongruent electroclinical features.

  8. Image city

    DEFF Research Database (Denmark)

    2003-01-01

    Image city exhibition explores a condition of mediation, through a focus on image and sound narratives with a point of departure on a number of Asian cities.......Image city exhibition explores a condition of mediation, through a focus on image and sound narratives with a point of departure on a number of Asian cities....

  9. Tselluloidi aura ja kaasaegne kunst / Hanno Soans

    Index Scriptorium Estoniae

    Soans, Hanno, 1974-

    2004-01-01

    Muutustest filmitegemises ja filmiesteetikas. Filmi sarnanemisest tehniliselt üha enam videoga. Kunstnike tegelemisest filmiga. 26. XI näeb kinos "Sõprus" "1+1=1" raames kaasaegsete kunstnike teoseid laiekraanil: Eija-Liisa Ahtila "If 6 was 9" (1995), "Today" (1996-97), "Consolation Service" (1999); Sara Lunden ja Henry Moore Selder (sünd. 1973, Stockholm) "Deadly Boring" (2001), "She is Dead" (2003)

  10. Epileptic consciousness: concept and meaning of aura.

    Science.gov (United States)

    Alvarez-Silva, Sergio; Alvarez-Silva, Iria; Alvarez-Rodriguez, Javier; Perez-Echeverria, M J; Campayo-Martinez, Antonio; Rodriguez-Fernandez, F L

    2006-05-01

    This research is based on previous publications that have analyzed certain neuropsychological phenomena that always have the same characteristic clinical features: a vivid experience of sudden onset and automatic development, accompanied by an intense sensation of strangeness. When these automatisms are accompanied by only mental symptoms, the designation paroxysmal psychic automatisms (PPAs) is proposed, and they should be interpreted as partial seizures (PSs) with a psychic content whenever they clearly exhibit the four features of suddenness, passivity, intensity, and strangeness. This interpretation is based on the existence of a wealth of scientific literature indicating an overlap between PPAs and PSs; moreover, bibliographic reviews indicate that the clinical signs just defined as characterizing PPAs are precisely those defining the epileptic consciousness.

  11. The Relevance Aura of Bibliographic Records.

    Science.gov (United States)

    Brooks, Terrence A.

    1997-01-01

    Analyzes relevance assessments of topical descriptors for bibliographic records for two dimensions: (1) a vertical conceptual hierarchy of broad to narrow descriptors, and (2) a horizontal linkage of related terms. The data were analyzed for a semantic distance and semantic direction effect as postulated by the Semantic Distance Model. (Author/LRW)

  12. A Statistical Study of Multiply Imaged Systems in the Lensing Cluster Abell 68

    Science.gov (United States)

    Richard, Johan; Kneib, Jean-Paul; Jullo, Eric; Covone, Giovanni; Limousin, Marceau; Ellis, Richard; Stark, Daniel; Bundy, Kevin; Czoske, Oliver; Ebeling, Harald; Soucail, Geneviève

    2007-06-01

    We have carried out an extensive spectroscopic survey with the Keck and VLT telescopes, targeting lensed galaxies in the background of the massive cluster Abell 68. Spectroscopic measurements are obtained for 26 lensed images, including a distant galaxy at z=5.4. Redshifts have been determined for 5 out of 7 multiple-image systems. Through a careful modeling of the mass distribution in the strongly lensed regime, we derive a mass estimate of 5.3×1014 Msolar within 500 kpc. Our mass model is then used to constrain the redshift distribution of the remaining multiply imaged and singly imaged sources. This enables us to examine the physical properties for a subsample of 7 Lyα emitters at 1.7financial support of the W. M. Keck Foundation. Also based on observations collected at the Very Large Telescope (Antu/UT1 and Melipal/UT3), European Southern Observatory, Paranal, Chile (ESO programs 070.A-0643 and 073.A-0774), the NASA/ESA Hubble Space Telescope (program 8249) obtained at the Space Telescope Science Institute, which is operated by AURA under NASA contract NAS5-26555, and the Canada-France-Hawaii Telescope (CFHT), which is operated by the National Research Council of Canada, the Institut National des Sciences de l'Univers of the Centre National de la Recherche Scientifique of France, and the University of Hawaii.

  13. Maxillofacial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Larheim, T.A. [Oslo Univ. (Norway). Dept. of Maxillofacial Radiology; Westesson, P.L. [Univ. of Rochester School of Medicine and Dentistry, NY (United States). Div. of Diagnostic and Interventional Radiology

    2006-07-01

    Maxillofacial imaging has evolved dramatically over the past two decades with development of new cross-sectional imaging techniques. Traditional maxillofacial imaging was based on plain films and dental imaging. However, today's advanced imaging techniques with CT and MRI have only been partially implemented for maxillofacial questions. This book bridges the gap between traditional maxillofacial imaging and advanced medical imaging. We have applied CT and MRI to a variety of maxillofacial cases and these are illustrated with high-quality images and multiple planes. A comprehensive chapter on imaging anatomy is also included. This book is useful for oral and maxillofacial radiologists, oral and maxillofacial surgeons, dentists, radiologists, plastic surgeons, head and neck surgeons, and others that work with severe maxillofacial disorders. (orig.)

  14. Hubble Space Telescope Image, Supernova Remnant Cassiopeia A

    Science.gov (United States)

    2000-01-01

    The colorful streamers that float across the sky in this photo taken by NASA's Hubble Space Telescope (HST) were created by the universe's biggest firecracker, the titanic supernova explosion of a massive star. The light from the exploding star reached Earth 320 years ago, nearly a century before the United States celebrated its birth with a bang. The dead star's shredded remains are called Cassiopeia A, or 'Cas A' for short. Cas A is the youngest known supernova remnant in our Milky Way Galaxy and resides 10,000 light-years away in the constellation Cassiopeia, so the star actually blew up 10,000 years before the light reached Earth in the late 1600s. This HST image of Cas A shows for the first time that the debris is arranged into thousands of small, cooling knots of gas. This material eventually will be recycled into building new generations of stars and planets. Our own Sun and planets are constructed from the debris of supernovae that exploded billions of years ago. This photo shows the upper rim of the super nova remnant's expanding shell. Near the top of the image are dozens of tiny clumps of matter. Each small clump, originally just a small fragment of the star, is tens of times larger than the diameter of our solar system. The colors highlight parts of the debris where chemical elements are glowing. The dark blue fragments, for example, are richest in oxygen; the red material is rich in sulfur. The images were taken with the Wide Field and Planetary Camera 2 in January 2000 and January 2002. Image Credit: NASA and HST team (Stoics/AURA). Acknowledgment: R. Fesen (Darmouth) and J. Morse ( Univ. of Colorado).

  15. Imaging angiogenesis.

    Science.gov (United States)

    Charnley, Natalie; Donaldson, Stephanie; Price, Pat

    2009-01-01

    There is a need for direct imaging of effects on tumor vasculature in assessment of response to antiangiogenic drugs and vascular disrupting agents. Imaging tumor vasculature depends on differences in permeability of vasculature of tumor and normal tissue, which cause changes in penetration of contrast agents. Angiogenesis imaging may be defined in terms of measurement of tumor perfusion and direct imaging of the molecules involved in angiogenesis. In addition, assessment of tumor hypoxia will give an indication of tumor vasculature. The range of imaging techniques available for these processes includes positron emission tomography (PET), dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), perfusion computed tomography (CT), and ultrasound (US).

  16. Spinal imaging and image analysis

    CERN Document Server

    Yao, Jianhua

    2015-01-01

    This book is instrumental to building a bridge between scientists and clinicians in the field of spine imaging by introducing state-of-the-art computational methods in the context of clinical applications.  Spine imaging via computed tomography, magnetic resonance imaging, and other radiologic imaging modalities, is essential for noninvasively visualizing and assessing spinal pathology. Computational methods support and enhance the physician’s ability to utilize these imaging techniques for diagnosis, non-invasive treatment, and intervention in clinical practice. Chapters cover a broad range of topics encompassing radiological imaging modalities, clinical imaging applications for common spine diseases, image processing, computer-aided diagnosis, quantitative analysis, data reconstruction and visualization, statistical modeling, image-guided spine intervention, and robotic surgery. This volume serves a broad audience as  contributions were written by both clinicians and researchers, which reflects the inte...

  17. Urogenital imaging

    International Nuclear Information System (INIS)

    Hamm, B.; Charite - Universitaetsmedizin Berlin; Asbach, P.; Beyersdorff, D.; Hein, P.; Lemke, U.

    2008-01-01

    The book in direct diagnosis in radiology, urogenital imaging, includes information concerning definition, imaging signs and clinical aspects on the following topics: kidneys and adrenals, the urinary tract, the male genitals and the female genitals

  18. Medical Imaging.

    Science.gov (United States)

    Barker, M. C. J.

    1996-01-01

    Discusses four main types of medical imaging (x-ray, radionuclide, ultrasound, and magnetic resonance) and considers their relative merits. Describes important recent and possible future developments in image processing. (Author/MKR)

  19. Microwave imaging

    CERN Document Server

    Pastorino, Matteo

    2010-01-01

    An introduction to the most relevant theoretical and algorithmic aspects of modern microwave imaging approaches Microwave imaging-a technique used in sensing a given scene by means of interrogating microwaves-has recently proven its usefulness in providing excellent diagnostic capabilities in several areas, including civil and industrial engineering, nondestructive testing and evaluation, geophysical prospecting, and biomedical engineering. Microwave Imaging offers comprehensive descriptions of the most important techniques so far proposed for short-range microwave imaging-in

  20. Tomographic imaging

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    Tomography is used to image anatomy of organs as in the case of CT and MRI or image body functions as in the case of SPECT and PET. The theory of reconstruction applies equally well to CT, SPECT and PET with a minor differences. The main difference between SPECT and PET is that SPECT images single photon emitters (radionuclides) which emit normal gamma rays (like Tc-99m), whereas PET images positron emitting radionuclides such as O 15 or F 18 . The word tomography means drawing of the body. Every tomography results in an image of the inside of the body and is represented as a slice. (author)

  1. Acoustical Imaging

    CERN Document Server

    Litniewski, Jerzy; Kujawska, Tamara; 31st International Symposium on Acoustical Imaging

    2012-01-01

    The International Symposium on Acoustical Imaging is a unique forum for advanced research, covering new technologies, developments, methods and theories in all areas of acoustics. This interdisciplinary Symposium has been taking place continuously since 1968. In the course of the years the proceedings volumes in the Acoustical Imaging Series have become a reference for cutting-edge research in the field. In 2011 the 31st International Symposium on Acoustical Imaging was held in Warsaw, Poland, April 10-13. Offering both a broad perspective on the state-of-the-art as well as  in-depth research contributions by the specialists in the field, this Volume 31 in the Series contains an excellent collection of papers in six major categories: Biological and Medical Imaging Physics and Mathematics of Acoustical Imaging Acoustic Microscopy Transducers and Arrays Nondestructive Evaluation and Industrial Applications Underwater Imaging

  2. Cerenkov Imaging

    OpenAIRE

    Das, Sudeep; Thorek, Daniel L.J.; Grimm, Jan

    2014-01-01

    Cerenkov luminescence (CL) has been used recently in a plethora of medical applications like imaging and therapy with clinically relevant medical isotopes. The range of medical isotopes used is fairly large and expanding. The generation of in vivo light is useful since it circumvents depth limitations for excitation light. Cerenkov luminescence imaging (CLI) is much cheaper in terms of infrastructure than positron emission tomography (PET) and is particularly useful for imaging of superficial...

  3. Image compression of bone images

    International Nuclear Information System (INIS)

    Hayrapetian, A.; Kangarloo, H.; Chan, K.K.; Ho, B.; Huang, H.K.

    1989-01-01

    This paper reports a receiver operating characteristic (ROC) experiment conducted to compare the diagnostic performance of a compressed bone image with the original. The compression was done on custom hardware that implements an algorithm based on full-frame cosine transform. The compression ratio in this study is approximately 10:1, which was decided after a pilot experiment. The image set consisted of 45 hand images, including normal images and images containing osteomalacia and osteitis fibrosa. Each image was digitized with a laser film scanner to 2,048 x 2,048 x 8 bits. Six observers, all board-certified radiologists, participated in the experiment. For each ROC session, an independent ROC curve was constructed and the area under that curve calculated. The image set was randomized for each session, as was the order for viewing the original and reconstructed images. Analysis of variance was used to analyze the data and derive statistically significant results. The preliminary results indicate that the diagnostic quality of the reconstructed image is comparable to that of the original image

  4. NMR imaging

    International Nuclear Information System (INIS)

    Andrew, E.R.

    1983-01-01

    Since hydrogen is the most abundant element in all living organisms, proton NMR lends itself well as a method of investigation in biology and medicine. NMR imaging has some special advantages as a diagnostic tool: no ionizing radiation is used, it is noninvasive; it provides a safer means of imaging than the use of x-rays, gamma rays, positrons, or heavy ions. In contrast with ultrasound, the radiation penetrates the bony structures without attenuation. In additional to morphological information, NMR imaging provides additional diagnostic insights through relaxation parameters, which are not available from other imaging methods. In the decade since the first primitive NMR images were obtained, the quality of images now obtained approaches those from CT x-ray scanners. Prototype instruments are being constructed for clinical evaluation and the first whole-body scanners are beginning to appear on the market at costs comparable to CT scanners. Primary differences in equipment for conventional NMR and NMR imaging are the much larger aperture magnets that are required for the examination of human subjects and the addition of coils to generate field gradients and facilities for manipulating the gradients. Early results from clinical trials in many parts of the world are encouraging, and in a few years, the usefuleness of this modality of medical imaging to the medical profession in diagnosis and treatment of disease will be defined. 10 figures

  5. Nuclear imaging

    International Nuclear Information System (INIS)

    Miller, J.H.; Reid, B.S.

    1985-01-01

    Nuclear imaging, utilizing relatively low photon energy emitting isotopes, allows an assessment of anatomic configuration and organ function. This method of imaging is predicted on the utilization of physiologically active radioisotope-labeled compounds or biologically active radioisotopes. Localization of such isotopes in normal or abnormal concentrations may be due to varying physiological or pathological mechanisms

  6. Cerenkov imaging.

    Science.gov (United States)

    Das, Sudeep; Thorek, Daniel L J; Grimm, Jan

    2014-01-01

    Cerenkov luminescence (CL) has been used recently in a plethora of medical applications like imaging and therapy with clinically relevant medical isotopes. The range of medical isotopes used is fairly large and expanding. The generation of in vivo light is useful since it circumvents depth limitations for excitation light. Cerenkov luminescence imaging (CLI) is much cheaper in terms of infrastructure than positron emission tomography (PET) and is particularly useful for imaging of superficial structures. Imaging can basically be done using a sensitive camera optimized for low-light conditions, and it has a better resolution than any other nuclear imaging modality. CLI has been shown to effectively diagnose disease with regularly used PET isotope ((18)F-FDG) in clinical setting. Cerenkov luminescence tomography, Cerenkov luminescence endoscopy, and intraoperative Cerenkov imaging have also been explored with positive conclusions expanding the current range of applications. Cerenkov has also been used to improve PET imaging resolution since the source of both is the radioisotope being used. Smart imaging agents have been designed based on modulation of the Cerenkov signal using small molecules and nanoparticles giving better insight of the tumor biology. © 2014 Elsevier Inc. All rights reserved.

  7. Brain imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.

    1978-01-01

    The techniques of brain imaging and results in perfusion studies and delayed images are outlined. An analysis of the advantages and disadvantages of the brain scan in a variety of common problems is discussed, especially as compared with other available procedures. Both nonneoplastic and neoplastic lesions are considered. (Auth/C.F.)

  8. Star Imager

    DEFF Research Database (Denmark)

    Madsen, Peter Buch; Jørgensen, John Leif; Thuesen, Gøsta

    1997-01-01

    The version of the star imager developed for Astrid II is described. All functions and features are described as well as the operations and the software protocol.......The version of the star imager developed for Astrid II is described. All functions and features are described as well as the operations and the software protocol....

  9. Retinal Imaging and Image Analysis

    Science.gov (United States)

    Abràmoff, Michael D.; Garvin, Mona K.; Sonka, Milan

    2011-01-01

    Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of blindness in the industrialized world that includes age-related macular degeneration, diabetic retinopathy, and glaucoma, the review is devoted to retinal imaging and image analysis methods and their clinical implications. Methods for 2-D fundus imaging and techniques for 3-D optical coherence tomography (OCT) imaging are reviewed. Special attention is given to quantitative techniques for analysis of fundus photographs with a focus on clinically relevant assessment of retinal vasculature, identification of retinal lesions, assessment of optic nerve head (ONH) shape, building retinal atlases, and to automated methods for population screening for retinal diseases. A separate section is devoted to 3-D analysis of OCT images, describing methods for segmentation and analysis of retinal layers, retinal vasculature, and 2-D/3-D detection of symptomatic exudate-associated derangements, as well as to OCT-based analysis of ONH morphology and shape. Throughout the paper, aspects of image acquisition, image analysis, and clinical relevance are treated together considering their mutually interlinked relationships. PMID:22275207

  10. Medical imaging

    CERN Document Server

    Townsend, David W

    1996-01-01

    Since the introduction of the X-ray scanner into radiology almost 25 years ago, non-invasive imaging has become firmly established as an essential tool in the diagnosis of disease. Fully three-dimensional imaging of internal organs is now possible, b and for studies which explore the functional status of the body. Powerful techniques to correlate anatomy and function are available, and scanners which combine anatomical and functional imaging in a single device are under development. Such techniques have been made possible through r ecent technological and mathematical advances. This series of lectures will review both the physical basis of medical imaging techniques using X-rays, gamma and positron emitting radiosiotopes, and nuclear magnetic resonance, and the mathematical methods used to reconstruct three-dimentional distributions from projection data. The lectures will trace the development of medical imaging from simple radiographs to the present-day non-invasive measurement of in vivo biochemistry. They ...

  11. Acoustical Imaging

    CERN Document Server

    Akiyama, Iwaki

    2009-01-01

    The 29th International Symposium on Acoustical Imaging was held in Shonan Village, Kanagawa, Japan, April 15-18, 2007. This interdisciplinary Symposium has been taking place every two years since 1968 and forms a unique forum for advanced research, covering new technologies, developments, methods and theories in all areas of acoustics. In the course of the years the volumes in the Acoustical Imaging Series have developed and become well-known and appreciated reference works. Offering both a broad perspective on the state-of-the-art in the field as well as an in-depth look at its leading edge research, this Volume 29 in the Series contains again an excellent collection of seventy papers presented in nine major categories: Strain Imaging Biological and Medical Applications Acoustic Microscopy Non-Destructive Evaluation and Industrial Applications Components and Systems Geophysics and Underwater Imaging Physics and Mathematics Medical Image Analysis FDTD method and Other Numerical Simulations Audience Researcher...

  12. Image perception and image processing

    Energy Technology Data Exchange (ETDEWEB)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures.

  13. Image perception and image processing

    International Nuclear Information System (INIS)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures. (orig.) [de

  14. Retinal imaging and image analysis

    NARCIS (Netherlands)

    Abramoff, M.D.; Garvin, Mona K.; Sonka, Milan

    2010-01-01

    Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of

  15. COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    Dominique Lafon

    2011-05-01

    Full Text Available The goal of this article is to present specific capabilities and limitations of the use of color digital images in a characterization process. The whole process is investigated, from the acquisition of digital color images to the analysis of the information relevant to various applications in the field of material characterization. A digital color image can be considered as a matrix of pixels with values expressed in a vector-space (commonly 3 dimensional space whose specificity, compared to grey-scale images, is to ensure a coding and a representation of the output image (visualisation printing that fits the human visual reality. In a characterization process, it is interesting to regard color image attnbutes as a set of visual aspect measurements on a material surface. Color measurement systems (spectrocolorimeters, colorimeters and radiometers and cameras use the same type of light detectors: most of them use Charge Coupled Devices sensors. The difference between the two types of color data acquisition systems is that color measurement systems provide a global information of the observed surface (average aspect of the surface: the color texture is not taken into account. Thus, it seems interesting to use imaging systems as measuring instruments for the quantitative characterization of the color texture.

  16. Image retrieval

    DEFF Research Database (Denmark)

    Ørnager, Susanne

    1997-01-01

    The paper touches upon indexing and retrieval for effective searches of digitized images. Different conceptions of what subject indexing means are described as a basis for defining an operational subject indexing strategy for images. The methodology is based on the art historian Erwin Panofsky......), special knowledge about image codes, and special knowledge about history of ideas. The semiologist Roland Barthes has established a semiology for pictorial expressions based on advertising photos. Barthes uses the concepts denotation/connotation where denotations can be explained as the sober expression...

  17. Image analysis

    International Nuclear Information System (INIS)

    Berman, M.; Bischof, L.M.; Breen, E.J.; Peden, G.M.

    1994-01-01

    This paper provides an overview of modern image analysis techniques pertinent to materials science. The usual approach in image analysis contains two basic steps: first, the image is segmented into its constituent components (e.g. individual grains), and second, measurement and quantitative analysis are performed. Usually, the segmentation part of the process is the harder of the two. Consequently, much of the paper concentrates on this aspect, reviewing both fundamental segmentation tools (commonly found in commercial image analysis packages) and more advanced segmentation tools. There is also a review of the most widely used quantitative analysis methods for measuring the size, shape and spatial arrangements of objects. Many of the segmentation and analysis methods are demonstrated using complex real-world examples. Finally, there is a discussion of hardware and software issues. 42 refs., 17 figs

  18. Medical imaging

    International Nuclear Information System (INIS)

    Loshkajian, A.

    2000-01-01

    This didactical book presents the medical imaging techniques: radiography, scanner, nuclear magnetic resonance (NMR). Examples are given for the most common pathologies in all domains of medicine. (J.S.)

  19. Image Sensor

    OpenAIRE

    Jerram, Paul; Stefanov, Konstantin

    2017-01-01

    An image sensor of the type for providing charge multiplication by impact ionisation has plurality of multiplication elements. Each element is arranged to receive charge from photosensitive elements of an image area and each element comprises a sequence of electrodes to move charge along a transport path. Each of the electrodes has an edge defining a boundary with a first electrode, a maximum width across the charge transport path and a leading edge that defines a boundary with a second elect...

  20. Brain imaging

    International Nuclear Information System (INIS)

    Greenfield, L.D.; Bennett, L.R.

    1976-01-01

    Imaging with radionuclides should be used in a complementary fashion with other neuroradiologic techniques. It is useful in the early detection and evaluation of intracranial neoplasm, cerebrovascular accident and abscess, and in postsurgical follow-up. Cisternography yields useful information about the functional status of cerebrospinal fluid pathways. Computerized axial tomography is a new technique of great promise that produced a cross-sectional image of the brain

  1. Emerging images

    KAUST Repository

    Mitra, Niloy J.

    2009-01-01

    Emergence refers to the unique human ability to aggregate information from seemingly meaningless pieces, and to perceive a whole that is meaningful. This special skill of humans can constitute an effective scheme to tell humans and machines apart. This paper presents a synthesis technique to generate images of 3D objects that are detectable by humans, but difficult for an automatic algorithm to recognize. The technique allows generating an infinite number of images with emerging figures. Our algorithm is designed so that locally the synthesized images divulge little useful information or cues to assist any segmentation or recognition procedure. Therefore, as we demonstrate, computer vision algorithms are incapable of effectively processing such images. However, when a human observer is presented with an emergence image, synthesized using an object she is familiar with, the figure emerges when observed as a whole. We can control the difficulty level of perceiving the emergence effect through a limited set of parameters. A procedure that synthesizes emergence images can be an effective tool for exploring and understanding the factors affecting computer vision techniques. © 2009 ACM.

  2. PC image processing

    International Nuclear Information System (INIS)

    Hwa, Mok Jin Il; Am, Ha Jeng Ung

    1995-04-01

    This book starts summary of digital image processing and personal computer, and classification of personal computer image processing system, digital image processing, development of personal computer and image processing, image processing system, basic method of image processing such as color image processing and video processing, software and interface, computer graphics, video image and video processing application cases on image processing like satellite image processing, color transformation of image processing in high speed and portrait work system.

  3. Medical imaging

    International Nuclear Information System (INIS)

    Elliott, Alex

    2005-01-01

    Diagnostic medical imaging is a fundamental part of the practice of modern medicine and is responsible for the expenditure of considerable amounts of capital and revenue monies in healthcare systems around the world. Much research and development work is carried out, both by commercial companies and the academic community. This paper reviews briefly each of the major diagnostic medical imaging techniques-X-ray (planar and CT), ultrasound, nuclear medicine (planar, SPECT and PET) and magnetic resonance. The technical challenges facing each are highlighted, with some of the most recent developments. In terms of the future, interventional/peri-operative imaging, the advancement of molecular medicine and gene therapy are identified as potential areas of expansion

  4. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  5. Fast imaging

    International Nuclear Information System (INIS)

    Wehrli, F.W.; Altas, S.W.

    1991-01-01

    This paper reports on MRI which has evolved rapidly and promises to continue to do so. The diagnostic armamentarium, as a result, has increased dramatically over recent years, which has necessitated constant interactions between clinicians, physicists, and biochemists. Pulse sequence design, coupled with advances in other software and hardware technology, offers practical improvements in scanning and image quality. Perhaps more importantly, these same advances hold promise for MRI to become, in addition to its traditional role as a morphological imaging technique, a functional imaging modality. The attractiveness of this prospect is that for the first time, a high-resolution technique has been shown to have the potential to provide both types of information from a single integrated examination, which promises to generate important insights into normal physiology as well as the natural history of pathophysiologic states

  6. Incompatible Images

    DEFF Research Database (Denmark)

    Sassene, Michel J.; Hertzum, Morten

    2008-01-01

    is, however, based on a taken-for-granted image of asthmatics as, per se, striving to be symptom-free. This image is incompatible with interviewed asthmatics' day-to-day performances of their asthma, and renders invisible (a) that their asthma performances emphasize an economy of good passages...... and of feeling capable, (b) that they achieve the objective of feeling capable in quite different ways, and (c) that feeling capable does not per se equal being symptom-free all the time. To attain long-term use of self-management systems and other patient-centred e-health systems, such systems must acknowledge...

  7. DBU's image

    OpenAIRE

    Nygaard, Katrin Hellesøe; Saugstrup, Annie; Yohannes, Adiam; Giesow, Katja Ludvigsen; Merved, Mikkel Dollerup

    2017-01-01

    The Danish Football Association (DBU) has a long history of crisis, which has led to a bad reputation for the organisation. The current crisis on the women’s national soccer team is in particular discussed in the media. Why are DBU often in crisis? How do they manage these crises and how does it affect their image? We are interested in identifying what they can do to change this pattern, which is why we conducted the following hypothesis: “DBU does still have an image problem“. We will examin...

  8. MRI (Magnetic Resonance Imaging)

    Science.gov (United States)

    ... Procedures Medical Imaging MRI (Magnetic Resonance Imaging) MRI (Magnetic Resonance Imaging) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Magnetic Resonance Imaging (MRI) is a medical imaging procedure for ...

  9. Imaging sciences workshop

    Energy Technology Data Exchange (ETDEWEB)

    Candy, J.V.

    1994-11-15

    This workshop on the Imaging Sciences sponsored by Lawrence Livermore National Laboratory contains short abstracts/articles submitted by speakers. The topic areas covered include the following: Astronomical Imaging; biomedical imaging; vision/image display; imaging hardware; imaging software; Acoustic/oceanic imaging; microwave/acoustic imaging; computed tomography; physical imaging; imaging algorithms. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  10. Forest Imaging

    Science.gov (United States)

    1992-01-01

    NASA's Technology Applications Center, with other government and academic agencies, provided technology for improved resources management to the Cibola National Forest. Landsat satellite images enabled vegetation over a large area to be classified for purposes of timber analysis, wildlife habitat, range measurement and development of general vegetation maps.

  11. Geriatric imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guglielmi, Giuseppe [Scientific Institute Casa Sollievo della Sofferenza Hospital, San Giovanni Rotondo (Italy). Dept. of Radiology; Peh, Wilfred C.G. [Khoo Teck Puat Hospital, Singapore (Singapore). Dept. of Diagnostic Radiology; Guermazi, Ali (eds.) [Boston Univ. School of Medicine, Boston, MA (United States). Dept. of Radiology

    2013-08-01

    Considers all aspect of geriatric imaging. Explains clearly how to distinguish the healthy elderly from those in need of treatment. Superbly illustrated. Written by recognized experts in field. In the elderly, the coexistence of various diseases, the presence of involutional and degenerative changes, and the occurrence of both physical and cognitive problems represent ''the norm.'' It is therefore important to know how to distinguish the healthy elderly from those in need of treatment as a sound basis for avoiding overdiagnosis and overtreatment. This aspect is a central theme in Geriatric Imaging, which covers a wide range of applications of different imaging techniques and clearly explains both the potential and the limitations of diagnostic imaging in geriatric patients. Individual sections are devoted to each major region or system of the body, and a concluding section focuses specifically on interventional procedures. The book, written by recognized experts in the field, is superbly illustrated and will be an ideal resource for geriatricians, radiologists, and trainees.

  12. Image categorization

    NARCIS (Netherlands)

    Klein Teeselink, G.; Blommaert, F.J.J.; Ridder, de H.

    2000-01-01

    A study was conducted to investigate whether images of natural scenes can be categorized with respect to information content and whether a relation exists with perceived foreground-background separation. In an experiment, one group of subjects carried out a 'free categorization' task, (subjects were

  13. Featured Image | Galaxy of Images

    Science.gov (United States)

    2,600 images. more info The Book of the Fair The first Ferris Wheel, the creation of bridge builder George W. Ferris, was erected at the World’s Columbian Exposition in Chicago in 1893. To commemorate

  14. Medical Imaging 4: Image formation

    International Nuclear Information System (INIS)

    Schneider, R.H.

    1990-01-01

    This book contains papers relating to the 1990 meeting of The International Society for Optical Engineering. Included are the following papers: Effect of protective layer on Resolution Properties of Photostimulable Phosphor Detector for Digital Radiographic System, Neural Network Scatter Correction Technique for Digital Radiography, Use of Computer Radiography for Portal Imaging

  15. European Space Imaging & Skybox Imaging

    International Nuclear Information System (INIS)

    Clark, J.; Schichor, P.

    2015-01-01

    Skybox and European Space Imaging have partnered to bring timely, Very High-Resolution imagery to customers in Europe and North Africa. Leveraging Silicon Valley ingenuity and world-class aerospace expertise, Skybox designs, builds, and operates a fleet of imaging satellites. With two satellites currently on-orbit, Skybox is quickly advancing towards a planned constellation of 24+ satellites with the potential for daily or sub-daily imaging at 70-90 cm resolution. With consistent, high-resolution imagery and video, European customers can monitor the dynamic units of human activity - cars, trucks, shipping containers, ships, aircraft, etc. - and derive valuable insights about the global economy. With multiple imaging opportunities per day, the Skybox constellation provides unprecedented access to imagery and information about critical targets that require rapid analysis. Skybox's unique capability to deliver high-definition video from space enables European customers to monitor a network of globally distributed assets with full-motion snapshots, without the need to deploy an aircraft or field team. The movement captured in these 30-90 second video windows yield unique insights that improve operational decisions. Skybox and EUSI are excited to offer a unique data source that can drive a better understanding of our world through supply chain monitoring, natural resource management, infrastructure monitoring, and crisis response. (author)

  16. Imaging dementias

    Energy Technology Data Exchange (ETDEWEB)

    Savoiardo, M.; Grisoli, M. [Dept. of Neuroradiology, Istituto Nazionale Neurologico, Milan (Italy)

    2001-03-01

    Dementia is the progressive loss of intellectual functions due to involvement of cortical or subcortical areas. Specific involvement of certain brain areas in the different diseases leads to impairment of different functions, e. g., memory, language, visuospatial abilities, and behavior. Magnetic resonance imaging and other neuroradiological studies may indicate which structures are mainly or selectively involved in a demented patient, thus allowing clinical-radiological correlations. Clinical presentation and evolution of the disease, supported by imaging studies, may lead to a highly probable diagnosis. The most common disorders, or the most relevant from the neuroradiological point of view, such as Alzheimer's disease, frontotemporal dementia, vascular dementias, dementia associated with parkinsonism, Huntington's disease, Creutzfeldt-Jakob disease, and normal-pressure hydrocephalus, are briefly discussed. (orig.)

  17. Image Analysis

    DEFF Research Database (Denmark)

    The 19th Scandinavian Conference on Image Analysis was held at the IT University of Copenhagen in Denmark during June 15-17, 2015. The SCIA conference series has been an ongoing biannual event for more than 30 years and over the years it has nurtured a world-class regional research and development...... area within the four participating Nordic countries. It is a regional meeting of the International Association for Pattern Recognition (IAPR). We would like to thank all authors who submitted works to this year’s SCIA, the invited speakers, and our Program Committee. In total 67 papers were submitted....... The topics of the accepted papers range from novel applications of vision systems, pattern recognition, machine learning, feature extraction, segmentation, 3D vision, to medical and biomedical image analysis. The papers originate from all the Scandinavian countries and several other European countries...

  18. Imaging dementias

    International Nuclear Information System (INIS)

    Savoiardo, M.; Grisoli, M.

    2001-01-01

    Dementia is the progressive loss of intellectual functions due to involvement of cortical or subcortical areas. Specific involvement of certain brain areas in the different diseases leads to impairment of different functions, e. g., memory, language, visuospatial abilities, and behavior. Magnetic resonance imaging and other neuroradiological studies may indicate which structures are mainly or selectively involved in a demented patient, thus allowing clinical-radiological correlations. Clinical presentation and evolution of the disease, supported by imaging studies, may lead to a highly probable diagnosis. The most common disorders, or the most relevant from the neuroradiological point of view, such as Alzheimer's disease, frontotemporal dementia, vascular dementias, dementia associated with parkinsonism, Huntington's disease, Creutzfeldt-Jakob disease, and normal-pressure hydrocephalus, are briefly discussed. (orig.)

  19. MR imaging

    International Nuclear Information System (INIS)

    Barbaric, Z.L.; Sukov, R.M.; Boechat, I.M.

    1988-01-01

    MR images were obtained from six patients with surgically proved hemorrhagic renal cysts and three with adult polycystic renal disease that contained many hemorrhagic cysts. Their appearance was compared with that of 30 simple renal cysts. Simple cysts were hypointense on T1-weighted spin-echo sequences and hyperintense to the kidney on T2-weighted sequences. On the same sequences, hemorrhagic cysts showed three patterns: (1) hyperintense-hyperintense, (2) isointense-hyperintense, and (3) hypointense-hypointense. The fluid-fluid interphase was identified in a number of hemorrhagic cysts on T2-weighted images. Three hemorrhagic cysts contained renal carcinoma. Hemorrhagic cysts may be impossible to differentiate from solid renal tumors except for layering

  20. Image construction

    International Nuclear Information System (INIS)

    1976-01-01

    An image processing system fitting in an X-ray television circuit for tomography is described. The profiles registered by the X-ray television circuit are projected on the screen of an afterglow cathode ray tube which registration is convoluted in an analogue system with the help of either a one-dimensional or a two-dimensional convolution function after which it is stored or processed further such that a clear tomogram is obtained

  1. Intravital Imaging

    OpenAIRE

    Pittet, Mikael J.; Weissleder, Ralph

    2011-01-01

    Until recently, the idea of observing life deep within the tissues of a living mouse, at a resolution sufficient to pick out cellular behaviors and molecular signals underlying them, remained a much-coveted dream. Now, a new era of intravital fluorescence microscopy has dawned. In this Primer, we review the technologies that made this revolution possible, and demonstrate how intravital imaging is beginning to provide quantitative and dynamic insights into cell biology, immunology, tumor biolo...

  2. Brain imaging

    International Nuclear Information System (INIS)

    Bradshaw, J.R.

    1989-01-01

    This book presents a survey of the various imaging tools with examples of the different diseases shown best with each modality. It includes 100 case presentations covering the gamut of brain diseases. These examples are grouped according to the clinical presentation of the patient: headache, acute headache, sudden unilateral weakness, unilateral weakness of gradual onset, speech disorders, seizures, pituitary and parasellar lesions, sensory disorders, posterior fossa and cranial nerve disorders, dementia, and congenital lesions

  3. Cardiovascular imaging

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Nuclear cardiology has grown exponentially over the past decade. The introduction of the gamma camera, the development of new radionuclides, and the implementation of computers have transformed the field of nuclear cardiology from largely research in the 1970s to routine clinical applications in the 1980s. At first, noninvasive nuclear imaging techniques were used predominantly to aid disease detection. In the ensuing years, emphasis has shifted to the functional assessment of patients with known disease. Widely available noninvasive techniques now allow the quantitative assessment of left and right ventricular function, one of the most important predictors of survival in patients with cardiac disease. Exercise radionuclide ventriculography provides valuable information on the myocardial reserve in patients with normal resting function. The serial measurement of the ventricular ejection fraction assists in the timing of valvular replacement therapy. In patients receiving doxorubicin, serial ejection fraction follow-up helps prevent the development of irreversible, drug-induced cardiomyopathy. It is now generally acknowledged that the detection of latent coronary disease is improved by the addition of 201 T1 imaging to the standard exercise electrocardiogram. Thallium imaging and infarct avid imaging with /sup 99m/Tc-pyrophosphate have proven useful in quantifying myocardial infarction size, and in assessing the value of therapy aimed at limiting infarction extent. In the evaluation of coronary artery disease, scintigraphy provides physiologic data that complements angiography, which is more anatomic. An angiographic lesion, read as a 70 percent narrowing, may not necessarily be flow-limiting, whereas one read as 40 percent, may, in fact, have physiologic consequences, if it is of sufficient length or eccentricity, or is in series with another insignificant stenosis

  4. Imaging system

    International Nuclear Information System (INIS)

    Rushbrooke, J.G.; Ansorge, R.E.

    1987-01-01

    A moving object such as a container on a conveyor belt is imaged by an optical system onto a charge coupled device array in which the lines of the array are arranged perpendicular to the direction of motion of the object. The speed of movement of the object is sensed to generate electrical signals which are processed to provide shift signals enabling the shifting of data row to row in the array in synchronism with the movement of the container. The electrical charge associated with a given point on the array is transferred from one line to the other until it appears at the last line of the array, from which it is read out in known manner in conjunction with all other electrical charges associated with the row of charge coupled devices in the last line of the array. Due to the integrating effect achieved, the aperture of the imaging system can be much smaller than otherwise would be required, and/or the level of light illumination can be reduced. The imaging system can be applied to X-ray inspection devices, aerial surveillance or scanning of moving documents in copying processes. (author)

  5. Genitourinary imaging

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The application of radionuclide studies in nephrology, urology, and gynecology has reached a measurable degree of maturity in recent years. However, the utilization of these techniques continues to be less frequent than the clinical advantages would seem to warrant, probably because of the complexities of renal physiology. This complexity has been resulted in the availability of large number of agents for renal studies. It is the functional nature of nuclear medicine studies that provides their tremendous potential for use in evaluation of the kidney, where the pathology of which is so often related to functional derangements rather than to anatomic problems. A familiarity with various measures of renal function and with the effects of these parameters on the handling of the commonly used radiopharmaceuticals is essential to the appropriate use of radionuclide studies. The types of studies commonly used include renal perfusion studies, renal imaging solely for anatomic information, and renal imaging combined with an estimate of renal function. Radionuclide techniques serve a complementary role to radiography, ultrasonography, and computed tomography in the morphologic diagnosis of renal diseases. Urethral abnormalities, bladder diverticula, and minimal distal urethral reflux are better demonstrated with radiographic than nuclear technique, but radionuclide cystography can be helpful for follow-up evaluations. Radionuclide testicular imaging is extremely useful in the differential diagnosis of testicular torsion

  6. Imaging AMS

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, S.P.H.T. [Univ. of Oxford (United Kingdom)]|[Lawrence Livermore National Lab., CA (United States); Ramsey, C.B.; Hedges, R.E.M. [Univ. of Oxford (United Kingdom)

    1993-12-01

    The benefits of simultaneous high effective mass resolution and large spectrometer acceptance that accelerator mass spectrometry has afforded the bulk analysis of material samples by secondary ion mass spectrometry may also be applied to imaging SIMS. The authors are exploring imaging AMS with the addition to the Oxford {sup 14}C-AMS system of a scanning secondary ion source. It employs a sub micron probe and a separate Cs flood to further increase the useful ion yield. The source has been accommodated on the system by directly injecting sputtered ions into the accelerator without mass analysis. They are detected with a range of devices including new high-bandwidth detectors. Qualitative mass spectra may be easily generated by varying only the post-accelerator analysis magnet. Selected ion signals may be used for imaging. In developing the instrument for bioscience research the authors are establishing its capability for measuring the lighter elements prevalent in biological tissue. Importantly, the machine can map the distributions of radiocarbon labeled compounds with an efficiency of about 1{per_thousand}. A background due to misidentification of non-{sup 14}C ions as a result of the reduced ion mass filtering is too small to hinder high magnification microscopy.

  7. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  8. A Wide-Field, Broadband Imaging Survey of Butcher-Oemler Cluster Cl 0024+1654: The Catalog

    Science.gov (United States)

    Alexov, A.; Silva, D. R.; Pierce, M. J.

    2003-12-01

    Wide-field (20'×20') UBVI images of intermediate-redshift (z=0.39), Butcher-Oemler cluster Cl 0024+1654 have been obtained. These data probe the rest-frame mid-UV properties over a much larger area than previous studies of Cl 0024+1654. Using these data, a multicolor catalog of nonstellar objects, assumed to be galaxies, has been constructed and analyzed. Using statistical arguments, the observed galaxy sample is separated into field and cluster populations. The basic photometric properties of these populations are presented and discussed. The ``dropout'' objects (i.e., objects undetected in one or more photometric bands) in our catalog are also discussed. A description of the final UBVI images, as well as the object catalog, is provided in an appendix. In a second appendix the use of SExtractor in crowded fields, such as the core of Cl 0024+1654, is discussed. The specific issues of the mid-UV properties of red envelope cluster galaxies, as well as the possible detection of a faint blue cluster population, are discussed in a forthcoming companion paper by Silva, Alexov, & Pierce. The observations described were conducted at Kitt Peak National Observatory, National Optical Astronomy Observatory, which is operated by the Association of Universities for Research in Astronomy (AURA) Inc., under cooperative agreement with the National Science Foundation (NSF).

  9. IMAGE DESCRIPTIONS FOR SKETCH BASED IMAGE RETRIEVAL

    OpenAIRE

    SAAVEDRA RONDO, JOSE MANUEL; SAAVEDRA RONDO, JOSE MANUEL

    2008-01-01

    Due to the massive use of Internet together with the proliferation of media devices, content based image retrieval has become an active discipline in computer science. A common content based image retrieval approach requires that the user gives a regular image (e.g, a photo) as a query. However, having a regular image as query may be a serious problem. Indeed, people commonly use an image retrieval system because they do not count on the desired image. An easy alternative way t...

  10. Intravital imaging.

    Science.gov (United States)

    Pittet, Mikael J; Weissleder, Ralph

    2011-11-23

    Until recently, the idea of observing life deep within the tissues of a living mouse, at a resolution sufficient to pick out cellular behaviors and molecular signals underlying them, remained a much-coveted dream. Now, a new era of intravital fluorescence microscopy has dawned. In this Primer, we review the technologies that made this revolution possible and demonstrate how intravital imaging is beginning to provide quantitative and dynamic insights into cell biology, immunology, tumor biology, and neurobiology. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Pituitary Imaging.

    Science.gov (United States)

    Pressman, Barry D

    2017-09-01

    Modern pituitary imaging is MRI. However, computed tomography (CT) still has limited usefulness. In addition, because CT offers much better bone detail and calcium detection, there are some cases in which such additional information is necessary. Before the advent of CT, plain radiography, pneumoencephalography, and angiography were used to diagnose pituitary masses. More recently, CT, and then especially MRI, made it possible to primarily delineate lesions within and around the pituitary gland rather than depend on secondary information that could only suggest their presence. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Imaging system

    International Nuclear Information System (INIS)

    Froggatt, R.J.

    1981-01-01

    The invention provides a two dimensional imaging system in which a pattern of radiation falling on the system is detected to give electrical signals for each of a plurality of strips across the pattern. The detection is repeated for different orientations of the strips and the whole processed by compensated back projection. For a shadow x-ray system a plurality of strip x-ray detectors are rotated on a turntable. For lower frequencies the pattern may be rotated with a Dove prism and the strips condensed to suit smaller detectors with a cylindrical lens. (author)

  13. Progress on molecular imaging

    International Nuclear Information System (INIS)

    Chen Quan; Zhang Yongxue

    2011-01-01

    Molecular imaging is a new era of medical imaging,which can non-invasively monitor biological processes at the cellular and molecular level in vivo, including molecular imaging of nuclear medicine, magnetic resonance molecular imaging, ultrasound molecular imaging,optical molecular imaging and molecular imaging with X-ray. Recently, with the development of multi-subjects amalgamation, multimodal molecular imaging technology has been applied in clinical imaging, such as PET-CT and PET-MRI. We believe that with development of molecular probe and multi-modal imaging, more and more molecular imaging techniques will be applied in clinical diagnosis and treatment. (authors)

  14. Imaging Case

    Directory of Open Access Journals (Sweden)

    Maria Adriana Rangel

    2018-04-01

    Full Text Available Introduction: Cephalohematoma is a collection of serosanguineous fluid below the periosteum and is the most frequent cranial injury in the newborn, occurring in 0.2-2.5% live births. The majority of cephalohematomas spontaneously resolve within three to four weeks, however, some persist beyond four weeks and begin to calcify. Case report: A seven-week-old boy, was referred to the emergency department because of a head lump on the right parietal region, with no other symptoms. He was born after a vacuum-assisted delivery, and presented a cephalohematoma in the first days of life, that progressively decreased and became more rigid. Physical examination, revealed a cranial asymmetry, and a head lump on the right parietal region, that was hard and fixed to the bone. Head X-ray revealed a radiopaque lump on the right parietal bone and a poorly defined arched line, as well as visible microcalcifications on the core of the cephalohematoma, typical findings of a calcified cephalohematoma. Discussion: Even though cephalohematoma is frequently encountered, calcified cephalohematoma is seen only sporadically, and is a rare clinical entity. History and clinical examination are important in the differential diagnosis and imaging strategy. Radiography and ultrasonography are often the initial screening diagnostic tests, followed by magnetic resonance imaging or computed tomography. Head x-ray features, in this case report, where particularly evocative of the diagnosis.

  15. Molecular MR Imaging Probes

    OpenAIRE

    MAHMOOD, UMAR; JOSEPHSON, LEE

    2005-01-01

    Magnetic resonance imaging (MRI) has been successfully applied to many of the applications of molecular imaging. This review discusses by example some of the advances in areas such as multimodality MR-optical agents, receptor imaging, apoptosis imaging, angiogenesis imaging, noninvasive cell tracking, and imaging of MR marker genes.

  16. Speckle imaging algorithms for planetary imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    I will discuss the speckle imaging algorithms used to process images of the impact sites of the collision of comet Shoemaker-Levy 9 with Jupiter. The algorithms use a phase retrieval process based on the average bispectrum of the speckle image data. High resolution images are produced by estimating the Fourier magnitude and Fourier phase of the image separately, then combining them and inverse transforming to achieve the final result. I will show raw speckle image data and high-resolution image reconstructions from our recent experiment at Lick Observatory.

  17. Geophysical validation and long-term consistency between GOME-2/MetOp-A total ozone column and measurements from the sensors GOME/ERS-2, SCIAMACHY/ENVISAT and OMI/Aura

    Directory of Open Access Journals (Sweden)

    M. E. Koukouli

    2012-09-01

    Full Text Available The main aim of the paper is to assess the consistency of five years of Global Ozone Monitoring Experiment-2/Metop-A [GOME-2] total ozone columns and the long-term total ozone satellite monitoring database already in existence through an extensive inter-comparison and validation exercise using as reference Brewer and Dobson ground-based measurements. The behaviour of the GOME-2 measurements is being weighed against that of GOME (1995–2011, Ozone Monitoring Experiment [OMI] (since 2004 and the Scanning Imaging Absorption spectroMeter for Atmospheric CartograpHY [SCIAMACHY] (since 2002 total ozone column products. Over the background truth of the ground-based measurements, the total ozone columns are inter-evaluated using a suite of established validation techniques; the GOME-2 time series follow the same patterns as those observed by the other satellite sensors. In particular, on average, GOME-2 data underestimate GOME data by about 0.80%, and underestimate SCIAMACHY data by 0.37% with no seasonal dependence of the differences between GOME-2, GOME and SCIAMACHY. The latter is expected since the three datasets are based on similar DOAS algorithms. This underestimation of GOME-2 is within the uncertainty of the reference data used in the comparisons. Compared to the OMI sensor, on average GOME-2 data underestimate OMI_DOAS (collection 3 data by 1.28%, without any significant seasonal dependence of the differences between them. The lack of seasonality might be expected since both the GOME data processor [GDP] 4.4 and OMI_DOAS are DOAS-type algorithms and both consider the variability of the stratospheric temperatures in their retrievals. Compared to the OMI_TOMS (collection 3 data, no bias was found. We hence conclude that the GOME-2 total ozone columns are well suitable to continue the long-term global total ozone record with the accuracy needed for climate monitoring studies.

  18. NMR imaging

    International Nuclear Information System (INIS)

    Ouchi, Toshihiro; Steiner, R.E.

    1984-01-01

    Three epidermoid and two dermoid tumours, pathologically proven, were examined by NMR and CT scans. Although most brain tumours have a low signal with a long T 1 , a dermoid cyst and one of the two components of the other dermoid tumour had a high signal and therefore a short T 1 . All three epidermoid tumours had a low signal and a long T 1 . Because of the high level contrast between some of the tumours and cerebrospinal fluid, NMR is helpful to detect the lesion. Neither of the liquid fluid levels in the tumour cysts or floating fat in the subarachnoid space was recognized in one patients, but the fine leakage of the content from the epidermoid cyst into the lateral ventricle was detected on a saturation recovery 1000 image in one case. (author)

  19. Medical Imaging System

    Science.gov (United States)

    1991-01-01

    The MD Image System, a true-color image processing system that serves as a diagnostic aid and tool for storage and distribution of images, was developed by Medical Image Management Systems, Huntsville, AL, as a "spinoff from a spinoff." The original spinoff, Geostar 8800, developed by Crystal Image Technologies, Huntsville, incorporates advanced UNIX versions of ELAS (developed by NASA's Earth Resources Laboratory for analysis of Landsat images) for general purpose image processing. The MD Image System is an application of this technology to a medical system that aids in the diagnosis of cancer, and can accept, store and analyze images from other sources such as Magnetic Resonance Imaging.

  20. Medical imaging technology

    CERN Document Server

    Haidekker, Mark A

    2013-01-01

    Biomedical imaging is a relatively young discipline that started with Conrad Wilhelm Roentgen’s discovery of the x-ray in 1885. X-ray imaging was rapidly adopted in hospitals around the world. However, it was the advent of computerized data and image processing that made revolutionary new imaging modalities possible. Today, cross-sections and three-dimensional reconstructions of the organs inside the human body is possible with unprecedented speed, detail and quality. This book provides an introduction into the principles of image formation of key medical imaging modalities: X-ray projection imaging, x-ray computed tomography, magnetic resonance imaging, ultrasound imaging, and radionuclide imaging. Recent developments in optical imaging are also covered. For each imaging modality, the introduction into the physical principles and sources of contrast is provided, followed by the methods of image formation, engineering aspects of the imaging devices, and a discussion of strengths and limitations of the modal...

  1. Foundations of image science

    CERN Document Server

    Barrett, Harrison H

    2013-01-01

    Winner of the 2006 Joseph W. Goodman Book Writing Award! A comprehensive treatment of the principles, mathematics, and statistics of image science In today's visually oriented society, images play an important role in conveying messages. From seismic imaging to satellite images to medical images, our modern society would be lost without images to enhance our understanding of our health, our culture, and our world. Foundations of Image Science presents a comprehensive treatment of the principles, mathematics, and st

  2. High energy positron imaging

    International Nuclear Information System (INIS)

    Chen Shengzu

    2003-01-01

    The technique of High Energy Positron Imaging (HEPI) is the new development and extension of Positron Emission Tomography (PET). It consists of High Energy Collimation Imaging (HECI), Dual Head Coincidence Detection Imaging (DHCDI) and Positron Emission Tomography (PET). We describe the history of the development and the basic principle of the imaging methods of HEPI in details in this paper. Finally, the new technique of the imaging fusion, which combined the anatomical image and the functional image together are also introduced briefly

  3. scikit-image: image processing in Python.

    Science.gov (United States)

    van der Walt, Stéfan; Schönberger, Johannes L; Nunez-Iglesias, Juan; Boulogne, François; Warner, Joshua D; Yager, Neil; Gouillart, Emmanuelle; Yu, Tony

    2014-01-01

    scikit-image is an image processing library that implements algorithms and utilities for use in research, education and industry applications. It is released under the liberal Modified BSD open source license, provides a well-documented API in the Python programming language, and is developed by an active, international team of collaborators. In this paper we highlight the advantages of open source to achieve the goals of the scikit-image library, and we showcase several real-world image processing applications that use scikit-image. More information can be found on the project homepage, http://scikit-image.org.

  4. scikit-image: image processing in Python

    Directory of Open Access Journals (Sweden)

    Stéfan van der Walt

    2014-06-01

    Full Text Available scikit-image is an image processing library that implements algorithms and utilities for use in research, education and industry applications. It is released under the liberal Modified BSD open source license, provides a well-documented API in the Python programming language, and is developed by an active, international team of collaborators. In this paper we highlight the advantages of open source to achieve the goals of the scikit-image library, and we showcase several real-world image processing applications that use scikit-image. More information can be found on the project homepage, http://scikit-image.org.

  5. Nuclear medicine imaging instrumentations for molecular imaging

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Song, Tae Yong; Choi, Yong

    2004-01-01

    Small animal models are extensively utilized in the study of biomedical sciences. Current animal experiments and analysis are largely restricted to in vitro measurements and need to sacrifice animals to perform tissue or molecular analysis. This prevents researchers from observing in vivo the natural evolution of the process under study. Imaging techniques can provide repeatedly in vivo anatomic and molecular information noninvasively. Small animal imaging systems have been developed to assess biological process in experimental animals and increasingly employed in the field of molecular imaging studies. This review outlines the current developments in nuclear medicine imaging instrumentations including fused multi-modality imaging systems for small animal imaging

  6. Joint imaging

    International Nuclear Information System (INIS)

    Hengst, W.

    1984-01-01

    Joint imaging is a proven diagnostic procedure which has become indispensable to the detection and treatment of different joint diseases in almost all disciplines. The method is suited for early diagnosis of joint affections both in soft tissue and bone which cannot be detected by X-ray or other procedures. The local activity accumulation depends on the rate of metabolism and is visualized in the scan, which in turn enables the extension and floridity of focal lesions to be evaluated and followed-up. Although joint scans may often give hints to probabilities relevant to differential diagnosis, the method is non-specific and only useful if based on the underlying clinical picture and X-ray finding, if possible. The radiation exposure is very low and does not represent a hazard in cases of adequate assessment of indication. In pregnant women and children the assessment of indication has to be based on very strict principles. The method is suited for out-patient diagnosis and can be applied in all installations equipped with a gamma camera and a technetium generator. (orig.) [de

  7. Pediatric magnetic resonance imaging

    International Nuclear Information System (INIS)

    Cohen, M.D.

    1986-01-01

    This book defines the current clinical potential of magnetic resonance imaging and focuses on direct clinical work with pediatric patients. A section dealing with the physics of magnetic resonance imaging provides an introduction to enable clinicians to utilize the machine and interpret the images. Magnetic resonance imaging is presented as an appropriate imaging modality for pediatric patients utilizing no radiation

  8. Identifying Image Manipulation Software from Image Features

    Science.gov (United States)

    2015-03-26

    scales”. Educational and Psychological Measurement, 20(1):37, 1960. 7. Committee, Technical Standardization. Exchangeable image file format for digital...Digital Forensics. Springer, 2005. 23. Photography, Technical Committee. Photography and graphic technology - Ex- tended colour encodings for digital image

  9. Image processing with ImageJ

    CERN Document Server

    Pascau, Javier

    2013-01-01

    The book will help readers discover the various facilities of ImageJ through a tutorial-based approach.This book is targeted at scientists, engineers, technicians, and managers, and anyone who wishes to master ImageJ for image viewing, processing, and analysis. If you are a developer, you will be able to code your own routines after you have finished reading this book. No prior knowledge of ImageJ is expected.

  10. Medical imaging 4

    International Nuclear Information System (INIS)

    Loew, M.H.

    1990-01-01

    This book is covered under the following topics: human visual pattern recognition, fractals, rules, and segments, three-dimensional image processing, MRI, MRI and mammography, clinical applications 1, angiography, image processing systems, image processing poster session

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes ...

  13. Outpatient Imaging Efficiency - State

    Data.gov (United States)

    U.S. Department of Health & Human Services — Use of medical imaging - state data. These measures give you information about hospitals' use of medical imaging tests for outpatients. Examples of medical imaging...

  14. Tomographic image reconstruction using training images

    DEFF Research Database (Denmark)

    Soltani, Sara; Andersen, Martin Skovgaard; Hansen, Per Christian

    2017-01-01

    We describe and examine an algorithm for tomographic image reconstruction where prior knowledge about the solution is available in the form of training images. We first construct a non-negative dictionary based on prototype elements from the training images; this problem is formulated within...

  15. To Image...or Not to Image?

    Science.gov (United States)

    Bruley, Karina

    1996-01-01

    Provides a checklist of considerations for installing document image processing with an electronic document management system. Other topics include scanning; indexing; the image file life cycle; benefits of imaging; document-driven workflow; and planning for workplace changes like postsorting, creating a scanning room, redeveloping job tasks and…

  16. Annotating images by mining image search results

    NARCIS (Netherlands)

    Wang, X.J.; Zhang, L.; Li, X.; Ma, W.Y.

    2008-01-01

    Although it has been studied for years by the computer vision and machine learning communities, image annotation is still far from practical. In this paper, we propose a novel attempt at model-free image annotation, which is a data-driven approach that annotates images by mining their search

  17. Image processing with ImageJ

    NARCIS (Netherlands)

    Abramoff, M.D.; Magalhães, Paulo J.; Ram, Sunanda J.

    2004-01-01

    Wayne Rasband of NIH has created ImageJ, an open source Java-written program that is now at version 1.31 and is used for many imaging applications, including those that that span the gamut from skin analysis to neuroscience. ImageJ is in the public domain and runs on any operating system (OS).

  18. Osteogenic sarcoma : imaging advances

    International Nuclear Information System (INIS)

    Gooding, C.A.

    1995-01-01

    The contents are classification of osteosarcoma, radiographic appearance, radionuclide imaging, PET - positron emission tomography scanning, arteriography, computed tomography, MRI imaging, response of chemotherapy (43 refs.)

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  20. Osteogenic sarcoma : imaging advances

    Energy Technology Data Exchange (ETDEWEB)

    Gooding, C A [California Univ., San Francisco, CA (United States)

    1996-12-31

    The contents are classification of osteosarcoma, radiographic appearance, radionuclide imaging, PET - positron emission tomography scanning, arteriography, computed tomography, MRI imaging, response of chemotherapy (43 refs.).

  1. Early (≤ 1-h) vs. late (>1-h) administration of frovatriptan plus dexketoprofen combination vs. frovatriptan monotherapy in the acute treatment of migraine attacks with or without aura: a post hoc analysis of a double-blind, randomized, parallel group study.

    Science.gov (United States)

    Allais, Gianni; Bussone, Gennaro; Tullo, Vincenzo; Cortelli, Pietro; Valguarnera, Fabio; Barbanti, Piero; Sette, Giuliano; Frediani, Fabio; D'Arrigo, Giacomo; d'Onofrio, Florindo; Comi, Giancarlo; Curone, Marcella; Colombo, Bruno; Omboni, Stefano; Benedetto, Chiara

    2015-05-01

    The early use of triptan in combination with a nonsteroidal anti-inflammatory drug after headache onset may improve the efficacy of acute migraine treatment. In this retrospective analysis of a randomized, double-blind, parallel group study, we assessed the efficacy of early or late intake of frovatriptan 2.5 mg + dexketoprofen 25 or 37.5 mg (FroDex 25 and FroDex 37.5) vs. frovatriptan 2.5 mg alone (Frova) in the acute treatment of migraine attacks. In this double-blind, randomized parallel group study 314 subjects with acute migraine with or without aura were randomly assigned to Frova, FroDex 25, or FroDex 37.5. Pain free (PF) at 2-h (primary endpoint), PF at 4-h and pain relief (PR) at 2 and 4-h, speed of onset at 60, 90, 120 and 240-min, and sustained pain free (SPF) at 24-h were compared across study groups according to early (≤1-h; n = 220) or late (>1-h; n = 59) intake. PF rates at 2 and 4-h were significantly larger with FroDex 37.5 vs. Frova (early intake, n = 71 FroDex 37.5 and n = 75 Frova: 49 vs. 32 % and 68 vs. 52 %, p < 0.05; late intake, n = 20 Frodex 37.5, and n = 18 Frova: 55 vs. 17 %, p < 0.05 and 85 vs. 28 %, p < 0.01). Also with FroDex 25, in the early intake group (n = 74) PF episodes were significantly higher than Frova. PR at 2 and 4-h was significantly better under FroDex 37.5 than Frova (95 % vs. 50 %, p < 0.001, 100 % vs. 72 %, p < 0.05) in the late intake group (n = 21). SPF episodes at 24-h after early dosing were 25 % (Frova), 45 % (FroDex 25) and 41 % (FroDex 37.5, p < 0.05 combinations vs. monotherapy), whereas they were not significantly different with late intake. All treatments were equally well tolerated. FroDex was similarly effective regardless of intake timing from headache onset.

  2. Image processing and recognition for biological images.

    Science.gov (United States)

    Uchida, Seiichi

    2013-05-01

    This paper reviews image processing and pattern recognition techniques, which will be useful to analyze bioimages. Although this paper does not provide their technical details, it will be possible to grasp their main tasks and typical tools to handle the tasks. Image processing is a large research area to improve the visibility of an input image and acquire some valuable information from it. As the main tasks of image processing, this paper introduces gray-level transformation, binarization, image filtering, image segmentation, visual object tracking, optical flow and image registration. Image pattern recognition is the technique to classify an input image into one of the predefined classes and also has a large research area. This paper overviews its two main modules, that is, feature extraction module and classification module. Throughout the paper, it will be emphasized that bioimage is a very difficult target for even state-of-the-art image processing and pattern recognition techniques due to noises, deformations, etc. This paper is expected to be one tutorial guide to bridge biology and image processing researchers for their further collaboration to tackle such a difficult target. © 2013 The Author Development, Growth & Differentiation © 2013 Japanese Society of Developmental Biologists.

  3. Imaging Sciences Workshop Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Candy, J.V.

    1996-11-21

    This report contains the proceedings of the Imaging Sciences Workshop sponsored by C.A.S.LS., the Center for Advanced Signal & Image Sciences. The Center, established primarily to provide a forum where researchers can freely exchange ideas on the signal and image sciences in a comfortable intellectual environment, has grown over the last two years with the opening of a Reference Library (located in Building 272). The Technical Program for the 1996 Workshop include a variety of efforts in the Imaging Sciences including applications in the Microwave Imaging, highlighted by the Micro-Impulse Radar (MIR) system invented at LLNL, as well as other applications in this area. Special sessions organized by various individuals in Speech, Acoustic Ocean Imaging, Radar Ocean Imaging, Ultrasonic Imaging, and Optical Imaging discuss various applica- tions of real world problems. For the more theoretical, sessions on Imaging Algorithms and Computed Tomography were organized as well as for the more pragmatic featuring a session on Imaging Systems.

  4. Adolescence and Body Image.

    Science.gov (United States)

    Weinshenker, Naomi

    2002-01-01

    Discusses body image among adolescents, explaining that today's adolescents are more prone to body image distortions and dissatisfaction than ever and examining the historical context; how self-image develops; normative discontent; body image distortions; body dysmorphic disorder (BDD); vulnerability of boys (muscle dysmorphia); who is at risk;…

  5. Digital Imaging. Chapter 16

    Energy Technology Data Exchange (ETDEWEB)

    Clunie, D. [CoreLab Partners, Princeton (United States)

    2014-09-15

    The original means of recording X ray images was a photographic plate. Nowadays, all medical imaging modalities provide for digital acquisition, though globally, the use of radiographic film is still widespread. Many modalities are fundamentally digital in that they require image reconstruction from quantified digital signals, such as computed tomography (CT) and magnetic resonance imaging (MRI)

  6. Towards exaggerated image stereotypes

    DEFF Research Database (Denmark)

    Chen, Chen; Lauze, Francois Bernard; Igel, Christian

    2011-01-01

    Given a training set of images and a binary classifier,we introduce the notion of an exaggerated image stereotype forsome image class of interest, which emphasizes/exaggerates thecharacteristic patterns in an image and visualizes which visualinformation the classification relies on. This is useful...

  7. Comparative cardiac imaging

    International Nuclear Information System (INIS)

    Brundage, B.H.

    1990-01-01

    This book is designed to compare all major cardiac imaging techniques. All major imaging techniques - including conventional angiography, digital angiography, echocardiography and Doppler imaging, conventional radioisotope techniques, computed tomography, and magnetic resonance imaging - are covered in this text as they apply to the major cardiovascular disorders. There is brief coverage of positron emission tomography and an extensive presentation of ultrafast computed tomography

  8. Mass preserving image registration

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin Chien Pau

    2010-01-01

    The paper presents results the mass preserving image registration method in the Evaluation of Methods for Pulmonary Image Registration 2010 (EMPIRE10) Challenge. The mass preserving image registration algorithm was applied to the 20 image pairs. Registration was evaluated using four different...

  9. In-Between-Images

    DEFF Research Database (Denmark)

    Fausing, Bent

    2013-01-01

    Article about Fascination, Affect, Interaction and Sensoric Images in Digital Culture and New Technology. I come up with a new term - 'In-Between-Images', which are the images created in between the perceiver and the perceived. We are active and interactive with these images, which are created out...

  10. Understanding Measurements Returned by the Helioseismic and Magnetic Imager

    Science.gov (United States)

    Cohen, Daniel Parke; Criscuoli, Serena

    2014-06-01

    The Helioseismic and Magnetic Imager (HMI) aboard the Solar Dynamics Observatory (SDO) observes the Sun at the FeI 6173 Å line and returns full disk maps of line-of-sight observables including the magnetic field flux, FeI line width, line depth, and continuum intensity. To properly interpret such data it is important to understand any issues with the HMI and the pipeline that produces these observables. At this aim, HMI data were analyzed at both daily intervals for a span of 3 years at disk center in the quiet Sun and hourly intervals for a span of 200 hours around an active region. Systematic effects attributed to issues with instrument adjustments and re-calibrations, variations in the transmission filters and the orbital velocities of the SDO were found while the actual physical evolutions of such observables were difficult to determine. Velocities and magnetic flux measurements are less affected, as the aforementioned effects are partially compensated for by the HMI algorithm; the other observables are instead affected by larger uncertainties. In order to model these uncertainties, the HMI pipeline was tested with synthetic spectra generated through various 1D atmosphere models with radiative transfer code (the RH code). It was found that HMI estimates of line width, line depth, and continuum intensity are highly dependent on the shape of the line, and therefore highly dependent on the line-of-sight angle and the magnetic field associated to the model. The best estimates are found for Quiet regions at disk center, for which the relative differences between theoretical and HMI algorithm values are 6-8% for line width, 10-15% for line depth, and 0.1-0.2% for continuum intensity. In general, the relative difference between theoretical values and HMI estimates increases toward the limb and with the increase of the field; the HMI algorithm seems to fail in regions with fields larger than ~2000 G. This work is carried out through the National Solar Observatory

  11. Advances in optical imaging

    International Nuclear Information System (INIS)

    Bremer, C.; Ntziachristos, V.; Mahmood, U.; Tung, C.H.; Weissleder, R.

    2001-01-01

    Different optical imaging technologies have significantly progressed over the last years. Besides advances in imaging techniques and image reconstruction, new 'smart' optical contrast agents have been developed which can be used to detect molecular targets (such as endogenous enzymes) in vivo. The combination of novel imaging technologies coupled with smart agents bears great diagnostic potential both clinically and experimentally. This overview outlines the basic principles of optical imaging and summarizes the current state of the art. (orig.) [de

  12. Magnetic resonance imaging (MRI

    Directory of Open Access Journals (Sweden)

    Takavar A

    1993-04-01

    Full Text Available Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I, a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D. factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  13. Magnetic resonance imaging (MRI)

    OpenAIRE

    Takavar A

    1993-01-01

    Basic physical principles of nuclear magnetic resonance imaging (N.M.R.I), a nonionizing medical imaging technique, are described. Principles of NMRI with other conventional imaging methods, ie, isotope scanning, ultrasonography and radiography have been compared. T1 and T2 and spin density (S.D.) factors and different image construction techniques based on their different combinations is discussed and at the end physical properties of some N.M.R images is mentioned.

  14. Hyperspectral imaging flow cytometer

    Science.gov (United States)

    Sinclair, Michael B.; Jones, Howland D. T.

    2017-10-25

    A hyperspectral imaging flow cytometer can acquire high-resolution hyperspectral images of particles, such as biological cells, flowing through a microfluidic system. The hyperspectral imaging flow cytometer can provide detailed spatial maps of multiple emitting species, cell morphology information, and state of health. An optimized system can image about 20 cells per second. The hyperspectral imaging flow cytometer enables many thousands of cells to be characterized in a single session.

  15. Abnormal Changes of Synaptic Excitability in Migraine with Aura

    DEFF Research Database (Denmark)

    Siniatchkin, Michael; Sendacki, Mascha; Moeller, Friederike

    2012-01-01

    simultaneously in migraineurs and healthy subjects. In order to investigate the homeostatic-like plasticity in the visual cortex, cortical excitability was modified using transcranial direct current stimulation (tDCS). Before any stimulation, migraineurs showed significantly higher glutamate/creatine ratios (Glx....../Cr) than healthy subjects. In healthy subjects, excitatory (anodal) tDCS caused an increase and inhibitory (cathodal) tDCS a decrease in the Glx/Cr ratio. Subsequent photic stimulation (PS) reversed the changes in Glx/Cr ratios, which returned back to baseline, demonstrating homeostatic-like metaplasticity...... in the control group. In migraine patients, both anodal and cathodal tDCS decreased the Glx/Cr ratio, which did not return to baseline after PS. While healthy subjects showed an increase in VEP amplitude under anodal and a reduction under cathodal tDCS, the modifiability of VEP under tDCS was reduced...

  16. Altered thalamic connectivity during spontaneous attacks of migraine without aura

    DEFF Research Database (Denmark)

    Amin, Faisal Mohammad; Hougaard, Anders; Magon, Stefano

    2017-01-01

    ,-58,-30) and cerebellum lobule VI (right, 34,-42,-36 and left, -32,-42,-36). Results We found increased functional connectivity between the right thalamus and several contralateral brain regions (superior parietal lobule, insular cortex, primary motor cortex, supplementary motor area and orbitofrontal cortex...... and the headache-free days. Functional connectivity was assessed in four different networks using seed-based analysis. The chosen seeds were in the thalamus (MNI coordinates x,y,z: right, 22,-24,0 and left, -22,-28,6), pons (right, 8,-24,-32 and left, -8,-24,-32), cerebellum crus I (right, 46,-58,-30 and left, -46......). There was decreased functional connectivity between the right thalamus and three ipsilateral brain areas (primary somatosensory cortex and premotor cortex). We found no change in functional connectivity in the pontine or the cerebellar networks. Conclusions The study indicates that network connectivity between...

  17. Walter Benjamin i l'aura de l'autobiografia

    OpenAIRE

    Martí Monterde, Antoni, 1968-

    2006-01-01

    És la biblioteca una forma d'autobiografia? Només caldria un sol escrit que ho demostrés de manera plena per a afirmar que sí, i aquest text el va escriure Walter Benjamin, qui el 17 de juliol de 1931 va publicar, a Die literarische Welt, 'un discurs sobre el col·leccionisme' sota el títol 'Tot desembolicant la meua biblioteca'.

  18. Global Gravity Wave Variances from Aura MLS: Characteristics and Interpretation

    Science.gov (United States)

    2008-12-01

    slight longitudinal variations, with secondary high- latitude peaks occurring over Greenland and Europe . As the QBO changes to the westerly phase, the...equatorial GW temperature variances from suborbital data (e.g., Eck- ermann et al. 1995). The extratropical wave variances are generally larger in the...emanating from tropopause altitudes, presumably radiated from tropospheric jet stream in- stabilities associated with baroclinic storm systems that

  19. Comment choisir ce qui aura été?

    DEFF Research Database (Denmark)

    Wilson, Alexander

    2015-01-01

    Many have invoked the nihilism that is endemic of the age we call the anthropocene. Bernard Stiegler has articulated this sentiment by highlighting how anthropocene films are typically nihilistic, for example, Von Trier’s Melancholia. But if the age is characterized by a cultural pessimism about...

  20. Endothelial Function in Migraine With Aura – A Systematic Review

    DEFF Research Database (Denmark)

    Butt, Jawad H; Franzmann, Ulriche; Kruuse, Christina

    2015-01-01

    in migraineurs, and several studies on endothelial markers in the areas of inflammation, oxidative stress, and coagulation found increased endothelial activation in migraineurs, particularly in MA. One study, assessing cerebral endothelial function using transcranial Doppler sonography, reported lower...

  1. Calcitonin gene-related peptide and migraine with aura

    DEFF Research Database (Denmark)

    Hansen, Jakob M; Ashina, Messoud

    2014-01-01

    on CGRP and MA. METHODS: We performed a systematic literature search on MEDLINE for reports of CGRP and MA, covering basic science, animal and human studies as well as randomized clinical trials. RESULTS: The literature search identified 594 citations, of which 38 contained relevant, original data. Plasma...

  2. Abnormal brain processing of pain in migraine without aura

    DEFF Research Database (Denmark)

    Buchgreitz, L.; Egsgaard, Line Lindhardt; Jensen, R.

    2010-01-01

    and somatosensory-evoked potentials were recorded with 128-channel EEG with and without concurrent induced tonic neck/shoulder muscle pain. At baseline, the calculated P300 dipole for single stimuli was localized in the cingulate cortex. In patients, but not in controls, the dipole changed position from baseline...

  3. Aura: A Multi-Featured Programming Framework in Python

    Directory of Open Access Journals (Sweden)

    2010-09-01

    Full Text Available This paper puts forward the design, programming and application of innovative educational software, ‘Aura’ made using Python and PyQt Python bindings. The research paper presents a new concept of using a single tool to relate between syntaxes of various programming languages and algorithms. It radically increases their understanding and retaining capacity, since they can correlate between many programming languages. The software is a totally unorthodox attempt towards helping students who have their first tryst with programming languages. The application is designed to help students understand how algorithms work and thus, help them in learning multiple programming languages on a single platform using an interactive graphical user interface. This paper elucidates how using Python and PyQt bindings, a comprehensive feature rich application, that implements an interactive algorithm building technique, a web browser, multiple programming language framework, a code generator and a real time code sharing hub be embedded into a single interface. And also explains, that using Python as building tool, it requires much less coding than conventional feature rich applications coded in other programming languages, and at the same time does not compromise on stability, inter-operability and robustness of the application.

  4. TES/Aura L2 Summary Profiles V005

    Data.gov (United States)

    National Aeronautics and Space Administration — Atmospheric vertical profile estimates, along with retrieved surface temperature, cloud effective optical depth, column estimates, quality flags, and a priori...

  5. TES/Aura L2 Summary Profiles V003

    Data.gov (United States)

    National Aeronautics and Space Administration — Atmospheric vertical profile estimates, along with retrieved surface temperature, cloud effective optical depth, column estimates, quality flags, and a priori...

  6. Characteristics of image converters and image intensifiers

    International Nuclear Information System (INIS)

    Gurvich, A.M.; Shamanov, A.A.; Rozenberg, A.M.; Fajnberg, V.S.; Kavtorova, V.P.; Salyuk, L.V.; Yakovleva, F.B.

    1978-01-01

    The characteristics of image converters and image intensifiers, which determine the range of the X-radiation dose rates used and the image quality, are considered. The equations for calculating the requirements to be imposed on the separate intensifier elements from known parameters of other elements with an allowance for the nonlinearity of the television system and the role of fluctuation in the space distribution of X-radiation quanta are given

  7. Image registration method for medical image sequences

    Science.gov (United States)

    Gee, Timothy F.; Goddard, James S.

    2013-03-26

    Image registration of low contrast image sequences is provided. In one aspect, a desired region of an image is automatically segmented and only the desired region is registered. Active contours and adaptive thresholding of intensity or edge information may be used to segment the desired regions. A transform function is defined to register the segmented region, and sub-pixel information may be determined using one or more interpolation methods.

  8. Rapid MR imaging

    International Nuclear Information System (INIS)

    Edelman, R.R.; Buxton, R.B.; Brady, T.J.

    1988-01-01

    Conventional magnetic resonance (MR) imaging methods typically require several minutes to produce an image, but the periods of respiration, cardiac motion and peristalsis are on the order of seconds or less. The need to reduce motion artifact, as well as the need to reduce imaging time for patient comfort and efficiency, have provided a strong impetus for the development of rapid imaging methods. For abdominal imaging, motion artifacts due to respiration can be significantly reduced by collecting the entire image during one breath hold. For other applications, such as following the kinetics of administered contrast agents, rapid imaging is essential to achieve adequate time resolution. A shorter imaging time entails a cost in image signal/noise (S/N), but improvements in recent years in magnet homogeneity, gradient and radiofrequency coil design have led to steady improvements in S/N and consequently in image quality. For many chemical applications the available S/N is greater than needed, and a trade-off of lower S/N for a shorter imaging time is acceptable. In this chapter, the authors consider the underlying principles of rapid imaging as well as clinical applications of these methods. The bulk of this review concentrates on short TR imaging, but methods that provide for a more modest decrease in imaging time as well as or those that dramatically shorten the imaging time to tens of milliseconds are also discussed

  9. Parallel MR imaging.

    Science.gov (United States)

    Deshmane, Anagha; Gulani, Vikas; Griswold, Mark A; Seiberlich, Nicole

    2012-07-01

    Parallel imaging is a robust method for accelerating the acquisition of magnetic resonance imaging (MRI) data, and has made possible many new applications of MR imaging. Parallel imaging works by acquiring a reduced amount of k-space data with an array of receiver coils. These undersampled data can be acquired more quickly, but the undersampling leads to aliased images. One of several parallel imaging algorithms can then be used to reconstruct artifact-free images from either the aliased images (SENSE-type reconstruction) or from the undersampled data (GRAPPA-type reconstruction). The advantages of parallel imaging in a clinical setting include faster image acquisition, which can be used, for instance, to shorten breath-hold times resulting in fewer motion-corrupted examinations. In this article the basic concepts behind parallel imaging are introduced. The relationship between undersampling and aliasing is discussed and two commonly used parallel imaging methods, SENSE and GRAPPA, are explained in detail. Examples of artifacts arising from parallel imaging are shown and ways to detect and mitigate these artifacts are described. Finally, several current applications of parallel imaging are presented and recent advancements and promising research in parallel imaging are briefly reviewed. Copyright © 2012 Wiley Periodicals, Inc.

  10. ImageSURF MOAB2 Image Example

    OpenAIRE

    O'Mara, Aidan R; Collins, Jessica M; King, Anna E; Vickers, James C; Kirkcaldie, Matthew T K

    2017-01-01

    A set of 2000x2000 confocal fluorescence images of MOAB2-labelled cortex from APPswe/PS1dE9 mouse models of Alzheimer's disease, sparsely annotated pixel labels and reference segmentation examples. Pixels are annotated as signal (red 0xFFFF0000) and background (blue 0xFF0000FF). Images were captured as stitched 12-bit greyscale single-plane images and cropped to size. Image acquisition was performed at 561nm excitation and 615nm emission wavelengths using a Perkin Elmer Ultraview VOX ima...

  11. Image registration via optimization over disjoint image regions

    Science.gov (United States)

    Pitts, Todd; Hathaway, Simon; Karelitz, David B.; Sandusky, John; Laine, Mark Richard

    2018-02-06

    Technologies pertaining to registering a target image with a base image are described. In a general embodiment, the base image is selected from a set of images, and the target image is an image in the set of images that is to be registered to the base image. A set of disjoint regions of the target image is selected, and a transform to be applied to the target image is computed based on the optimization of a metric over the selected set of disjoint regions. The transform is applied to the target image so as to register the target image with the base image.

  12. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murphy, W.A.

    1988-01-01

    After only a few years, MR imaging has proved to be an important method for imaging disorders of the musculoskeletal tissues. The images are characterized by great inherent contrast, excellent spatial resolution, and exquisite anatomic display - major reasons why MR imaging compares favorably with other imaging methods, such as radionuclide bone scanning and CT. MR imaging is particularly sensitive to bone marrow alterations and is very effective for detection and characterization of a wide variety of soft tissue conditions. Advances in surface coil technology will increase the usefulness of MR imaging in the evaluation of articular disease. In addition, chemical shift imaging and spectroscopy will add physiologic information to the anatomic features demonstrated by proton imaging

  13. Multispectral imaging for biometrics

    Science.gov (United States)

    Rowe, Robert K.; Corcoran, Stephen P.; Nixon, Kristin A.; Ostrom, Robert E.

    2005-03-01

    Automated identification systems based on fingerprint images are subject to two significant types of error: an incorrect decision about the identity of a person due to a poor quality fingerprint image and incorrectly accepting a fingerprint image generated from an artificial sample or altered finger. This paper discusses the use of multispectral sensing as a means to collect additional information about a finger that significantly augments the information collected using a conventional fingerprint imager based on total internal reflectance. In the context of this paper, "multispectral sensing" is used broadly to denote a collection of images taken under different polarization conditions and illumination configurations, as well as using multiple wavelengths. Background information is provided on conventional fingerprint imaging. A multispectral imager for fingerprint imaging is then described and a means to combine the two imaging systems into a single unit is discussed. Results from an early-stage prototype of such a system are shown.

  14. Distance between images

    Science.gov (United States)

    Gualtieri, J. A.; Le Moigne, J.; Packer, C. V.

    1992-01-01

    Comparing two binary images and assigning a quantitative measure to this comparison finds its purpose in such tasks as image recognition, image compression, and image browsing. This quantitative measurement may be computed by utilizing the Hausdorff distance of the images represented as two-dimensional point sets. In this paper, we review two algorithms that have been proposed to compute this distance, and we present a parallel implementation of one of them on the MasPar parallel processor. We study their complexity and the results obtained by these algorithms for two different types of images: a set of displaced pairs of images of Gaussian densities, and a comparison of a Canny edge image with several edge images from a hierarchical region growing code.

  15. Terahertz composite imaging method

    Institute of Scientific and Technical Information of China (English)

    QIAO Xiaoli; REN Jiaojiao; ZHANG Dandan; CAO Guohua; LI Lijuan; ZHANG Xinming

    2017-01-01

    In order to improve the imaging quality of terahertz(THz) spectroscopy, Terahertz Composite Imaging Method(TCIM) is proposed. The traditional methods of improving THz spectroscopy image quality are mainly from the aspects of de-noising and image enhancement. TCIM breaks through this limitation. A set of images, reconstructed in a single data collection, can be utilized to construct two kinds of composite images. One algorithm, called Function Superposition Imaging Algorithm(FSIA), is to construct a new gray image utilizing multiple gray images through a certain function. The features of the Region Of Interest (ROI) are more obvious after operating, and it has capability of merging ROIs in multiple images. The other, called Multi-characteristics Pseudo-color Imaging Algorithm(McPcIA), is to construct a pseudo-color image by combining multiple reconstructed gray images in a single data collection. The features of ROI are enhanced by color differences. Two algorithms can not only improve the contrast of ROIs, but also increase the amount of information resulting in analysis convenience. The experimental results show that TCIM is a simple and effective tool for THz spectroscopy image analysis.

  16. Molecular photoacoustic imaging

    Directory of Open Access Journals (Sweden)

    Frogh Jafarian Dehkordi

    2015-04-01

    Full Text Available Background: Hybrid imaging modalities which simultaneously benefit from capabilities of combined modalities provides an opportunity to modify quality of the images which can be obtained by each of the combined imaging systems. One of the imaging modalities, emerged in medical research area as a hybrid of ultrasound imaging and optical imaging, is photoacoustic imaging which apply ultrasound wave generated by tissue, after receiving laser pulse, to produce medical images. Materials and Methods: In this review, using keywords such as photoacoustic, optoacoustic, laser-ultrasound, thermoacoustic at databases such as PubMed and ISI, studies performed in the field of photoacoustic and related findings were evaluated. Results: Photoacoustic imaging, acquiring images with high contrast and desired resolution, provides an opportunity to perform physiologic and anatomic studies. Because this technique does not use ionizing radiation, it is not restricted by the limitation of the ionizing-based imaging systems therefore it can be used noninvasively to make images from cell, vessels, whole body imaging of the animal and distinguish tumor from normal tissue. Conclusion: Photoacoustic imaging is a new method in preclinical researches which can be used in various physiologic and anatomic studies. This method, because of application of non-ionizing radiation, may resolve limitation of radiation based method in diagnostic assessments.

  17. Multimodality imaging techniques.

    Science.gov (United States)

    Martí-Bonmatí, Luis; Sopena, Ramón; Bartumeus, Paula; Sopena, Pablo

    2010-01-01

    In multimodality imaging, the need to combine morphofunctional information can be approached by either acquiring images at different times (asynchronous), and fused them through digital image manipulation techniques or simultaneously acquiring images (synchronous) and merging them automatically. The asynchronous post-processing solution presents various constraints, mainly conditioned by the different positioning of the patient in the two scans acquired at different times in separated machines. The best solution to achieve consistency in time and space is obtained by the synchronous image acquisition. There are many multimodal technologies in molecular imaging. In this review we will focus on those multimodality image techniques more commonly used in the field of diagnostic imaging (SPECT-CT, PET-CT) and new developments (as PET-MR). The technological innovations and development of new tracers and smart probes are the main key points that will condition multimodality image and diagnostic imaging professionals' future. Although SPECT-CT and PET-CT are standard in most clinical scenarios, MR imaging has some advantages, providing excellent soft-tissue contrast and multidimensional functional, structural and morphological information. The next frontier is to develop efficient detectors and electronics systems capable of detecting two modality signals at the same time. Not only PET-MR but also MR-US or optic-PET will be introduced in clinical scenarios. Even more, MR diffusion-weighted, pharmacokinetic imaging, spectroscopy or functional BOLD imaging will merge with PET tracers to further increase molecular imaging as a relevant medical discipline. Multimodality imaging techniques will play a leading role in relevant clinical applications. The development of new diagnostic imaging research areas, mainly in the field of oncology, cardiology and neuropsychiatry, will impact the way medicine is performed today. Both clinical and experimental multimodality studies, in

  18. Synthetic Aperture Ultrasound Imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav; Gammelmark, Kim Løkke

    2006-01-01

    The paper describes the use of synthetic aperture (SA) imaging in medical ultrasound. SA imaging is a radical break with today's commercial systems, where the image is acquired sequentially one image line at a time. This puts a strict limit on the frame rate and the possibility of acquiring...... a sufficient amount of data for high precision flow estimation. These constrictions can be lifted by employing SA imaging. Here data is acquired simultaneously from all directions over a number of emissions, and the full image can be reconstructed from this data. The talk will demonstrate the many benefits...

  19. Remote sensing image fusion

    CERN Document Server

    Alparone, Luciano; Baronti, Stefano; Garzelli, Andrea

    2015-01-01

    A synthesis of more than ten years of experience, Remote Sensing Image Fusion covers methods specifically designed for remote sensing imagery. The authors supply a comprehensive classification system and rigorous mathematical description of advanced and state-of-the-art methods for pansharpening of multispectral images, fusion of hyperspectral and panchromatic images, and fusion of data from heterogeneous sensors such as optical and synthetic aperture radar (SAR) images and integration of thermal and visible/near-infrared images. They also explore new trends of signal/image processing, such as

  20. Targeted molecular imaging

    International Nuclear Information System (INIS)

    Kim, E. Edmund

    2003-01-01

    Molecular imaging aims to visualize the cellular and molecular processes occurring in living tissues, and for the imaging of specific molecules in vivo, the development of reporter probes and dedicated imaging equipment is most important. Reporter genes can be used to monitor the delivery and magnitude of therapeutic gene transfer, and the time variation involved. Imaging technologies such as micro-PET, SPECT, MRI and CT, as well as optical imaging systems, are able to non-invasively detect, measure, and report the simultaneous expression of multiple meaningful genes. It is believed that recent advances in reporter probes, imaging technologies and gene transfer strategies will enhance the effectiveness of gene therapy trials

  1. Infrared upconversion hyperspectral imaging

    DEFF Research Database (Denmark)

    Kehlet, Louis Martinus; Tidemand-Lichtenberg, Peter; Dam, Jeppe Seidelin

    2015-01-01

    In this Letter, hyperspectral imaging in the mid-IR spectral region is demonstrated based on nonlinear frequency upconversion and subsequent imaging using a standard Si-based CCD camera. A series of upconverted images are acquired with different phase match conditions for the nonlinear frequency...... conversion process. From this, a sequence of monochromatic images in the 3.2-3.4 mu m range is generated. The imaged object consists of a standard United States Air Force resolution target combined with a polystyrene film, resulting in the presence of both spatial and spectral information in the infrared...... image. (C) 2015 Optical Society of America...

  2. Image registration of naval IR images

    Science.gov (United States)

    Rodland, Arne J.

    1996-06-01

    In a real world application an image from a stabilized sensor on a moving platform will not be 100 percent stabilized. There will always be a small unknown error in the stabilization due to factors such as dynamic deformations in the structure between sensor and reference Inertial Navigation Unit, servo inaccuracies, etc. For a high resolution imaging sensor this stabilization error causes the image to move several pixels in unknown direction between frames. TO be able to detect and track small moving objects from such a sensor, this unknown movement of the sensor image must be estimated. An algorithm that searches for land contours in the image has been evaluated. The algorithm searches for high contrast points distributed over the whole image. As long as moving objects in the scene only cover a small area of the scene, most of the points are located on solid ground. By matching the list of points from frame to frame, the movement of the image due to stabilization errors can be estimated and compensated. The point list is searched for points with diverging movement from the estimated stabilization error. These points are then assumed to be located on moving objects. Points assumed to be located on moving objects are gradually exchanged with new points located in the same area. Most of the processing is performed on the list of points and not on the complete image. The algorithm is therefore very fast and well suited for real time implementation. The algorithm has been tested on images from an experimental IR scanner. Stabilization errors were added artificially to the image such that the output from the algorithm could be compared with the artificially added stabilization errors.

  3. Radiological Image Compression

    Science.gov (United States)

    Lo, Shih-Chung Benedict

    The movement toward digital images in radiology presents the problem of how to conveniently and economically store, retrieve, and transmit the volume of digital images. Basic research into image data compression is necessary in order to move from a film-based department to an efficient digital -based department. Digital data compression technology consists of two types of compression technique: error-free and irreversible. Error -free image compression is desired; however, present techniques can only achieve compression ratio of from 1.5:1 to 3:1, depending upon the image characteristics. Irreversible image compression can achieve a much higher compression ratio; however, the image reconstructed from the compressed data shows some difference from the original image. This dissertation studies both error-free and irreversible image compression techniques. In particular, some modified error-free techniques have been tested and the recommended strategies for various radiological images are discussed. A full-frame bit-allocation irreversible compression technique has been derived. A total of 76 images which include CT head and body, and radiographs digitized to 2048 x 2048, 1024 x 1024, and 512 x 512 have been used to test this algorithm. The normalized mean -square-error (NMSE) on the difference image, defined as the difference between the original and the reconstructed image from a given compression ratio, is used as a global measurement on the quality of the reconstructed image. The NMSE's of total of 380 reconstructed and 380 difference images are measured and the results tabulated. Three complex compression methods are also suggested to compress images with special characteristics. Finally, various parameters which would effect the quality of the reconstructed images are discussed. A proposed hardware compression module is given in the last chapter.

  4. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1996-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging; describe some of the image registration methods that have been developed to determine geometric errors quantitatively; discuss some of the ways that portal imaging has been incorporated into routine clinical practice; describe quality assurance procedures for these devices, and discuss the use of portal imaging devices for dosimetry applications. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices can be classified into three categories: T.V. camera-based systems, liquid ionisation chamber systems, and amorphous silicon systems. Many factors influence the quality of images generated by these portal imaging systems. These include factors which are unavoidable (e.g., low subject contrast), factors which depend upon the individual imaging device forming the image (e.g., dose utilisation, spatial resolution) as well as factors which depend upon the characteristics of the linear accelerator irradiating the imaging system (x-ray source size, image magnification). The characteristics of individual imaging systems, such as spatial resolution, temporal response, and quantum utilisation will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. However, the task is not nearly as straight-forward as it sounds. One problem

  5. Imaging Food Quality

    DEFF Research Database (Denmark)

    Møller, Flemming

    Imaging and spectroscopy have long been established methods for food quality control both in the laboratories and online. An ever increasing number of analytical techniques are being developed into imaging methods and existing imaging methods to contain spectral information. Images and especially...... spectral images contain large amounts of data which should be analysed appropriately by techniques combining structure and spectral information. This dissertation deals with how different types of food quality can be measured by imaging techniques, analysed with appropriate image analysis techniques...... and finally use the image data to predict or visualise food quality. A range of different food quality parameters was addressed, i.e. water distribution in bread throughout storage, time series analysis of chocolate milk stability, yoghurt glossiness, graininess and dullness and finally structure and meat...

  6. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, Mohammad Akbar Hosain

    2014-12-04

    Various examples are provided for generalized internal multiple imaging (GIMI). In one example, among others, a method includes generating a higher order internal multiple image using a background Green\\'s function and rendering the higher order internal multiple image for presentation. In another example, a system includes a computing device and a generalized internal multiple imaging (GIMI) application executable in the computing device. The GIMI application includes logic that generates a higher order internal multiple image using a background Green\\'s function and logic that renders the higher order internal multiple image for display on a display device. In another example, a non-transitory computer readable medium has a program executable by processing circuitry that generates a higher order internal multiple image using a background Green\\'s function and renders the higher order internal multiple image for display on a display device.

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of North America ( ...

  8. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, M. A. H.; Alkhalifah, Tariq Ali

    2014-01-01

    Internal multiples deteriorate the image when the imaging procedure assumes only single scattering, especially if the velocity model does not have sharp contrasts to reproduce such scattering in the Green’s function through forward modeling

  9. Apollo Image Atlas

    Data.gov (United States)

    National Aeronautics and Space Administration — The Apollo Image Atlas is a comprehensive collection of Apollo-Saturn mission photography. Included are almost 25,000 lunar images, both from orbit and from the...

  10. Images in kidney trauma

    International Nuclear Information System (INIS)

    Rodriguez, Jose Luis; Rodriguez, Sonia Pilar; Manzano, Ana Cristina

    2007-01-01

    A case of a 3 years old female patient, who suffered blunt lumbar trauma (horse kick) with secondary kidney trauma, is reported. Imaging findings are described. Renal trauma classification and imaging findings are reviewed

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  14. Radionuclide reporter gene imaging

    International Nuclear Information System (INIS)

    Min, Jung Joon

    2004-01-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases

  15. Hepatitis B virus (image)

    Science.gov (United States)

    Hepatitis B is also known as serum hepatitis and is spread through blood and sexual contact. It is ... population. This photograph is an electronmicroscopic image of hepatitis B virus particles. (Image courtesy of the Centers for ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound ... computer or television monitor. The image is created based on the amplitude (loudness), frequency (pitch) and time ...

  18. Abdominal ultrasound (image)

    Science.gov (United States)

    Abdominal ultrasound is a scanning technique used to image the interior of the abdomen. Like the X- ... use high frequency sound waves to produce an image and do not expose the individual to radiation. ...

  19. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, Mohammad Akbar Hosain; Alkhalifah, Tariq

    2014-01-01

    Various examples are provided for generalized internal multiple imaging (GIMI). In one example, among others, a method includes generating a higher order internal multiple image using a background Green's function and rendering the higher order internal multiple image for presentation. In another example, a system includes a computing device and a generalized internal multiple imaging (GIMI) application executable in the computing device. The GIMI application includes logic that generates a higher order internal multiple image using a background Green's function and logic that renders the higher order internal multiple image for display on a display device. In another example, a non-transitory computer readable medium has a program executable by processing circuitry that generates a higher order internal multiple image using a background Green's function and renders the higher order internal multiple image for display on a display device.

  20. NAIP Public Image Services

    Data.gov (United States)

    Farm Service Agency, Department of Agriculture — This map provides a preview and information about the National Agriculture Imagery Program (NAIP) image services available on the APFO public image server. Click on...

  1. Radionuclide reporter gene imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Joon [School of Medicine, Chonnam National Univ., Gwangju (Korea, Republic of)

    2004-04-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases.

  2. Outpatient Imaging Efficiency - National

    Data.gov (United States)

    U.S. Department of Health & Human Services — Use of medical imaging - national data. These measures give you information about hospitals' use of medical imaging tests for outpatients. Examples of medical...

  3. Light Imaging Section

    Data.gov (United States)

    Federal Laboratory Consortium — The mission of the Light Imaging Section is to give NIAMS scientists access to state-of-the-art light imaging equipment and to offer training and assistance at all...

  4. Magnetic resonance vascular imaging

    International Nuclear Information System (INIS)

    Axel, L

    1989-01-01

    The basis principles of MRI are reviewed in order to understand how blood flow effects arise in conventional imaging. Then some of the ways these effects have ben used in MRI techniques specifically designed for vascular imaging, are considered. (author)

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ... not provide cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic ...

  6. Quantum Temporal Imaging

    OpenAIRE

    Tsang, Mankei; Psaltis, Demetri

    2006-01-01

    The concept of quantum temporal imaging is proposed to manipulate the temporal correlation of entangled photons. In particular, we show that time correlation and anticorrelation can be converted to each other using quantum temporal imaging.

  7. Spectral Imaging by Upconversion

    DEFF Research Database (Denmark)

    Dam, Jeppe Seidelin; Pedersen, Christian; Tidemand-Lichtenberg, Peter

    2011-01-01

    We present a method to obtain spectrally resolved images using upconversion. By this method an image is spectrally shifted from one spectral region to another wavelength. Since the process is spectrally sensitive it allows for a tailored spectral response. We believe this will allow standard...... silicon based cameras designed for visible/near infrared radiation to be used for spectral images in the mid infrared. This can lead to much lower costs for such imaging devices, and a better performance....

  8. Coherent imaging at FLASH

    International Nuclear Information System (INIS)

    Chapman, H N; Bajt, S; Duesterer, S; Treusch, R; Barty, A; Benner, W H; Bogan, M J; Frank, M; Hau-Riege, S P; Woods, B W; Boutet, S; Cavalleri, A; Hajdu, J; Iwan, B; Seibert, M M; Timneanu, N; Marchesini, S; Sakdinawat, A; Sokolowski-Tinten, K

    2009-01-01

    We have carried out high-resolution single-pulse coherent diffractive imaging at the FLASH free-electron laser. The intense focused FEL pulse gives a high-resolution low-noise coherent diffraction pattern of an object before that object turns into a plasma and explodes. In particular we are developing imaging of biological specimens beyond conventional radiation damage resolution limits, developing imaging of ultrafast processes, and testing methods to characterize and perform single-particle imaging.

  9. Processing of medical images

    International Nuclear Information System (INIS)

    Restrepo, A.

    1998-01-01

    Thanks to the innovations in the technology for the processing of medical images, to the high development of better and cheaper computers, and, additionally, to the advances in the systems of communications of medical images, the acquisition, storage and handling of digital images has acquired great importance in all the branches of the medicine. It is sought in this article to introduce some fundamental ideas of prosecution of digital images that include such aspects as their representation, storage, improvement, visualization and understanding

  10. Image quality (IQ) guided multispectral image compression

    Science.gov (United States)

    Zheng, Yufeng; Chen, Genshe; Wang, Zhonghai; Blasch, Erik

    2016-05-01

    Image compression is necessary for data transportation, which saves both transferring time and storage space. In this paper, we focus on our discussion on lossy compression. There are many standard image formats and corresponding compression algorithms, for examples, JPEG (DCT -- discrete cosine transform), JPEG 2000 (DWT -- discrete wavelet transform), BPG (better portable graphics) and TIFF (LZW -- Lempel-Ziv-Welch). The image quality (IQ) of decompressed image will be measured by numerical metrics such as root mean square error (RMSE), peak signal-to-noise ratio (PSNR), and structural Similarity (SSIM) Index. Given an image and a specified IQ, we will investigate how to select a compression method and its parameters to achieve an expected compression. Our scenario consists of 3 steps. The first step is to compress a set of interested images by varying parameters and compute their IQs for each compression method. The second step is to create several regression models per compression method after analyzing the IQ-measurement versus compression-parameter from a number of compressed images. The third step is to compress the given image with the specified IQ using the selected compression method (JPEG, JPEG2000, BPG, or TIFF) according to the regressed models. The IQ may be specified by a compression ratio (e.g., 100), then we will select the compression method of the highest IQ (SSIM, or PSNR). Or the IQ may be specified by a IQ metric (e.g., SSIM = 0.8, or PSNR = 50), then we will select the compression method of the highest compression ratio. Our experiments tested on thermal (long-wave infrared) images (in gray scales) showed very promising results.

  11. Dictionary Based Image Segmentation

    DEFF Research Database (Denmark)

    Dahl, Anders Bjorholm; Dahl, Vedrana Andersen

    2015-01-01

    We propose a method for weakly supervised segmentation of natural images, which may contain both textured or non-textured regions. Our texture representation is based on a dictionary of image patches. To divide an image into separated regions with similar texture we use an implicit level sets...

  12. Medical imaging systems

    Science.gov (United States)

    Frangioni, John V

    2013-06-25

    A medical imaging system provides simultaneous rendering of visible light and diagnostic or functional images. The system may be portable, and may include adapters for connecting various light sources and cameras in open surgical environments or laparascopic or endoscopic environments. A user interface provides control over the functionality of the integrated imaging system. In one embodiment, the system provides a tool for surgical pathology.

  13. Imaging in aortic dissection

    International Nuclear Information System (INIS)

    Yu-Qing Liu, M.D.

    1995-01-01

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.)

  14. Ambient mass spectrometry imaging

    DEFF Research Database (Denmark)

    Janfelt, Christian; Nørgaard, Asger W

    2012-01-01

    , resulting in images of similar quality as DESI. EASI can thus be used in imaging experiments where the application of high voltage is impractical or undesirable. The present study is in its nature also a comparison of the characteristics of the two techniques, showing results also applicable for non-imaging...

  15. Negotiating the thumbnail image

    DEFF Research Database (Denmark)

    Thylstrup, Nanna Bonde; Teilmann-Lock, Stina

    2017-01-01

    Thumbnail images are discreet, yet central navigational tools in increasingly complex visual information environments. Indeed, without thumbnail images there would be no image search: they are an inherent part of the information architecture of most digital information platforms. Yet, how might w...

  16. Long range image enhancement

    CSIR Research Space (South Africa)

    Duvenhage, B

    2015-11-01

    Full Text Available the surveillance system performance. This paper discusses an image processing method that tracks the behaviour of the PSF and then de-warps the image to reduce the disruptive effects of turbulence. Optical flow, an average image filter and a simple unsharp mask...

  17. Classification in Medical Imaging

    DEFF Research Database (Denmark)

    Chen, Chen

    Classification is extensively used in the context of medical image analysis for the purpose of diagnosis or prognosis. In order to classify image content correctly, one needs to extract efficient features with discriminative properties and build classifiers based on these features. In addition...... on characterizing human faces and emphysema disease in lung CT images....

  18. Microwave Breast Imaging Techniques

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Rubæk, Tonny

    2010-01-01

    This paper outlines the applicability of microwave radiation for breast cancer detection. Microwave imaging systems are categorized based on their hardware architecture. The advantages and disadvantages of various imaging techniques are discussed. The fundamental tradeoffs are indicated between...... various requirements to be fulfilled in the design of an imaging system for breast cancer detection and some strategies to overcome these limitations....

  19. Medical ultrasound imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2007-01-01

    The paper gives an introduction to current medical ultrasound imaging systems. The basics of anatomic and blood flow imaging are described. The properties of medical ultrasound and its focusing are described, and the various methods for two- and three-dimensional imaging of the human anatomy...

  20. Imaging of hemophilic pseudotumor

    International Nuclear Information System (INIS)

    Ruiz, F.; Reche, A.; Garcia, E.; Chamorro, C.

    2002-01-01

    A case of hemophilic pseudotumor studied with different imaging techniques is reported. Typical and atypical images that may guide the individualized management of each patient are reviewed. In this case, imaging techniques were especially useful in guiding the biopsy. (Author) 14 refs

  1. Hyperspectral image processing methods

    Science.gov (United States)

    Hyperspectral image processing refers to the use of computer algorithms to extract, store and manipulate both spatial and spectral information contained in hyperspectral images across the visible and near-infrared portion of the electromagnetic spectrum. A typical hyperspectral image processing work...

  2. Imaging in aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Qing Liu, M D [Chinese Academy of Medical Sciences, Beijing, BJ (China). Dept. of Radiology, Fu Wai Hospital and Cardiovascular Inst.

    1996-12-31

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.).

  3. Image scaling curve generation

    NARCIS (Netherlands)

    2012-01-01

    The present invention relates to a method of generating an image scaling curve, where local saliency is detected in a received image. The detected local saliency is then accumulated in the first direction. A final scaling curve is derived from the detected local saliency and the image is then

  4. Image scaling curve generation.

    NARCIS (Netherlands)

    2011-01-01

    The present invention relates to a method of generating an image scaling curve, where local saliency is detected in a received image. The detected local saliency is then accumulated in the first direction. A final scaling curve is derived from the detected local saliency and the image is then

  5. Cardiac magnetic resonance imaging

    African Journals Online (AJOL)

    2011-03-06

    Mar 6, 2011 ... Cardiac magnetic resonance imaging. Cardiovascular magnetic resonance imaging is becoming a routine diagnostic technique. BRUCE s sPOTTiswOOdE, PhD. MRC/UCT Medical Imaging Research Unit, University of Cape Town, and Division of Radiology, Stellenbosch University. Bruce Spottiswoode ...

  6. Near-Electrode Imager

    Energy Technology Data Exchange (ETDEWEB)

    Rathke, Jerome W.; Klingler, Robert J.; Woelk, Klaus; Gerald, Rex E.,II

    1999-05-01

    An apparatus, near-electrode imager, for employing nuclear magnetic resonance imaging to provide in situ measurements of electrochemical properties of a sample as a function of distance from a working electrode. The near-electrode imager use the radio frequency field gradient within a cylindrical toroid cavity resonator to provide high-resolution nuclear magnetic resonance spectral information on electrolyte materials.

  7. IMAGES OF DECOLONIZATION / IMAGES DE LA DECOLONISATION

    OpenAIRE

    Ganapathy-Doré , Geetha; Olinga , Michel; Crowley , Cornelius; Naumann , Michel; Le Boulicaut , Yannick; Coulardeau , Jacques; Taouchichet , Sofiane; Éric Owono Zambo , Claude; Dosoruth , Sonia; Vilar , Fernanda; Griffin , Patrick

    2013-01-01

    Il s'agit d'un document avec références.; International audience; This collected anthology of essays on the Images of Decolonization follows in the footsteps of an earlier SARI publication on Changing Images of India and Africa (Paris: L'Harmattan, 2011). It approaches the idea of decolonization from the point of view of the politics of representation with articles on the gaze of colonial and postcolonial photographers, the fantasized images of indigenous women (Pocahontas in the USA and La M...

  8. Methods in Astronomical Image Processing

    Science.gov (United States)

    Jörsäter, S.

    A Brief Introductory Note History of Astronomical Imaging Astronomical Image Data Images in Various Formats Digitized Image Data Digital Image Data Philosophy of Astronomical Image Processing Properties of Digital Astronomical Images Human Image Processing Astronomical vs. Computer Science Image Processing Basic Tools of Astronomical Image Processing Display Applications Calibration of Intensity Scales Calibration of Length Scales Image Re-shaping Feature Enhancement Noise Suppression Noise and Error Analysis Image Processing Packages: Design of AIPS and MIDAS AIPS MIDAS Reduction of CCD Data Bias Subtraction Clipping Preflash Subtraction Dark Subtraction Flat Fielding Sky Subtraction Extinction Correction Deconvolution Methods Rebinning/Combining Summary and Prospects for the Future

  9. Generalized internal multiple imaging

    KAUST Repository

    Zuberi, M. A. H.

    2014-08-05

    Internal multiples deteriorate the image when the imaging procedure assumes only single scattering, especially if the velocity model does not have sharp contrasts to reproduce such scattering in the Green’s function through forward modeling. If properly imaged, internal multiples (internally scattered energy) can enhance the seismic image. Conventionally, to image internal multiples, accurate, sharp contrasts in the velocity model are required to construct a Green’s function with all the scattered energy. As an alternative, we have developed a generalized internal multiple imaging procedure that images any order internal scattering using the background Green’s function (from the surface to each image point), constructed from a smooth velocity model, usually used for conventional imaging. For the first-order internal multiples, the approach consisted of three steps, in which we first back propagated the recorded surface seismic data using the background Green’s function, then crosscorrelated the back-propagated data with the recorded data, and finally crosscorrelated the result with the original background Green’s function. This procedure images the contribution of the recorded first-order internal multiples, and it is almost free of the single-scattering recorded energy. The cost includes one additional crosscorrelation over the conventional single-scattering imaging application. We generalized this method to image internal multiples of any order separately. The resulting images can be added to the conventional single-scattering image, obtained, e.g., from Kirchhoff or reverse-time migration, to enhance the image. Application to synthetic data with reflectors illuminated by multiple scattering (double scattering) demonstrated the effectiveness of the approach.

  10. Application of image editing software for forensic detection of image ...

    African Journals Online (AJOL)

    Application of image editing software for forensic detection of image. ... The image editing software's available today is apt for creating visually compelling and sophisticated fake images, ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  11. Hip Imaging in Athletes: Sports Imaging Series.

    Science.gov (United States)

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.

  12. Fourier plane imaging microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez, Daniel, E-mail: daniel.dominguez@ttu.edu; Peralta, Luis Grave de [Department of Physics, Texas Tech University, Lubbock, Texas 79409 (United States); Nano Tech Center, Texas Tech University, Lubbock, Texas 79409 (United States); Alharbi, Nouf; Alhusain, Mdhaoui [Department of Physics, Texas Tech University, Lubbock, Texas 79409 (United States); Bernussi, Ayrton A. [Nano Tech Center, Texas Tech University, Lubbock, Texas 79409 (United States); Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409 (United States)

    2014-09-14

    We show how the image of an unresolved photonic crystal can be reconstructed using a single Fourier plane (FP) image obtained with a second camera that was added to a traditional compound microscope. We discuss how Fourier plane imaging microscopy is an application of a remarkable property of the obtained FP images: they contain more information about the photonic crystals than the images recorded by the camera commonly placed at the real plane of the microscope. We argue that the experimental results support the hypothesis that surface waves, contributing to enhanced resolution abilities, were optically excited in the studied photonic crystals.

  13. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  14. Birth room images

    DEFF Research Database (Denmark)

    Bowden, Calida; Sheehan, Athena; Foureur, Maralyn Jean

    2016-01-01

    Objective: this study examined images of birth rooms in developed countries to analyse the messages and visual discourse being communicated through images. Design: a small qualitative study using Kress and van Leeuwen's (2006) social semiotic theoretical framework for image analysis, a form...... and implications for practice: as images on the Internet inform and persuade society about stereotypical behaviours, the trends of our time and sociocultural norms, it is important to recognise images of the technological birth room on the Internet may be influential in dictating women's attitudes, choices...

  15. Satellite image collection optimization

    Science.gov (United States)

    Martin, William

    2002-09-01

    Imaging satellite systems represent a high capital cost. Optimizing the collection of images is critical for both satisfying customer orders and building a sustainable satellite operations business. We describe the functions of an operational, multivariable, time dynamic optimization system that maximizes the daily collection of satellite images. A graphical user interface allows the operator to quickly see the results of what if adjustments to an image collection plan. Used for both long range planning and daily collection scheduling of Space Imaging's IKONOS satellite, the satellite control and tasking (SCT) software allows collection commands to be altered up to 10 min before upload to the satellite.

  16. Introducing Zoomify Image

    OpenAIRE

    Adam Smith

    2007-01-01

    Zoomify Image is a mature product for easily publishing large, high-resolution images on the Web. End users view these images with existing Webbrowser software as quickly as they do normal, downsampled images. A Flash-based Zoomifyer client asynchronously streams image data to the Web browser as needed, resulting in response times approaching those of desktop applications using minimal bandwidth. The author, a librarian at Cornell University and the principal architect of a small, open-source...

  17. Images of Usability

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2010-01-01

    unless confronted with alternative images. This study delineates six images of usability: universal usability, situational usability, perceived usability, hedonic usability, organizational usability, and cultural usability. The different foci of the images provide opportunities for becoming sensitized...... assume different images of usability and a need for supplementary methods addressing the collaborative and long-term aspects of usability. Moreover, the images call for extending the scope of practical usability work to include the effects achieved by users during their use of systems for real work....

  18. Skeletal imaging composition

    International Nuclear Information System (INIS)

    Vanduzee, B.F.; Degenhardt, C.R.

    1983-01-01

    This invention is based on the discovery that the adjustment of pH, within a particular range, during the process of manufacturing lyophilized diphosphonate-containing skeletal imaging kits yields a kit which produces a technetium skeletal imaging agent with superior imaging properties. This increased performance is manifested through faster blood clearance and higher skeletal uptake of the technetium imaging agent. The process for producing a dry-powder imaging kit comprises the steps of: preparing a solution of a diphosphonate carrier, stannous reductant, and a stabilizer in water; adjusting the pH to between 5.5 and 6.5; and lyophilizing the solution

  19. Lyophilized skeletal imaging composition

    International Nuclear Information System (INIS)

    Vanduzee, B.F.

    1983-01-01

    This invention encompasses a process for producing a dry-powder skeletal imaging kit. An aqueous solution of a diphosphonate, a stannous reductant, and, optionally, a stabilizer is prepared. The solution is adjusted to a pH within the range 4.2 to 4.8 and the pH-adjusted solution is then lyophilized. The adjustment of pH, within a particular range, during the process of manufacturing lyophilized diphosphonate containing skeletal imaging kits yields a kit which produces a technetium skeletal imaging agent with superior imaging properties. This improved performance is manifested through faster blood clearance and higher skeletal uptake of the technetium imaging agent

  20. Experimental image alignment system

    Science.gov (United States)

    Moyer, A. L.; Kowel, S. T.; Kornreich, P. G.

    1980-01-01

    A microcomputer-based instrument for image alignment with respect to a reference image is described which uses the DEFT sensor (Direct Electronic Fourier Transform) for image sensing and preprocessing. The instrument alignment algorithm which uses the two-dimensional Fourier transform as input is also described. It generates signals used to steer the stage carrying the test image into the correct orientation. This algorithm has computational advantages over algorithms which use image intensity data as input and is suitable for a microcomputer-based instrument since the two-dimensional Fourier transform is provided by the DEFT sensor.

  1. ImagingSIMS

    Energy Technology Data Exchange (ETDEWEB)

    2017-11-06

    ImagingSIMS is an open source application for loading, processing, manipulating and visualizing secondary ion mass spectrometry (SIMS) data. At PNNL, a separate branch has been further developed to incorporate application specific features for dynamic SIMS data sets. These include loading CAMECA IMS-1280, NanoSIMS and modified IMS-4f raw data, creating isotopic ratio images and stitching together images from adjacent interrogation regions. In addition to other modifications of the parent open source version, this version is equipped with a point-by-point image registration tool to assist with streamlining the image fusion process.

  2. Annotating images by mining image search results.

    Science.gov (United States)

    Wang, Xin-Jing; Zhang, Lei; Li, Xirong; Ma, Wei-Ying

    2008-11-01

    Although it has been studied for years by the computer vision and machine learning communities, image annotation is still far from practical. In this paper, we propose a novel attempt at model-free image annotation, which is a data-driven approach that annotates images by mining their search results. Some 2.4 million images with their surrounding text are collected from a few photo forums to support this approach. The entire process is formulated in a divide-and-conquer framework where a query keyword is provided along with the uncaptioned image to improve both the effectiveness and efficiency. This is helpful when the collected data set is not dense everywhere. In this sense, our approach contains three steps: 1) the search process to discover visually and semantically similar search results, 2) the mining process to identify salient terms from textual descriptions of the search results, and 3) the annotation rejection process to filter out noisy terms yielded by Step 2. To ensure real-time annotation, two key techniques are leveraged-one is to map the high-dimensional image visual features into hash codes, the other is to implement it as a distributed system, of which the search and mining processes are provided as Web services. As a typical result, the entire process finishes in less than 1 second. Since no training data set is required, our approach enables annotating with unlimited vocabulary and is highly scalable and robust to outliers. Experimental results on both real Web images and a benchmark image data set show the effectiveness and efficiency of the proposed algorithm. It is also worth noting that, although the entire approach is illustrated within the divide-and conquer framework, a query keyword is not crucial to our current implementation. We provide experimental results to prove this.

  3. Imaging in nuclear medicine

    International Nuclear Information System (INIS)

    Giussani, Augusto; Hoeschen, Christoph

    2013-01-01

    Presents the most recent developments in nuclear medicine imaging, with emphasis on the latest research findings. Considers the latest advances in imaging systems, image reconstruction, noise correction, and quality assurance. Discusses novel concepts, including those developed within the framework of the EURATOM FP7 MADEIRA project. Lists rules of thumb for imaging of use to both beginners and experienced researchers. This volume addresses a wide range of issues in the field of nuclear medicine imaging, with an emphasis on the latest research findings. Initial chapters set the scene by considering the role of imaging in nuclear medicine from the medical perspective and discussing the implications of novel agents and applications for imaging. The physics at the basis of the most modern imaging systems is described, and the reader is introduced to the latest advances in image reconstruction and noise correction. Various novel concepts are then discussed, including those developed within the framework of the EURATOM FP7 MADEIRA research project on the optimization of imaging procedures in order to permit a reduction in the radiation dose to healthy tissues. Advances in quality control and quality assurance are covered, and the book concludes by listing rules of thumb for imaging that will be of use to both beginners and experienced researchers.

  4. Imaging in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Giussani, Augusto [BfS - Federal Office for Radiation Protection, Oberschleissheim (Germany). Dept. of Radiation Protection and Health; Hoeschen, Christoph (eds.) [Helmholtz Zentrum Muenchen - German Research Center for Environmental Health, Neuherberg (Germany). Research Unit Medical Raditation Physics and Diagnostics

    2013-08-01

    Presents the most recent developments in nuclear medicine imaging, with emphasis on the latest research findings. Considers the latest advances in imaging systems, image reconstruction, noise correction, and quality assurance. Discusses novel concepts, including those developed within the framework of the EURATOM FP7 MADEIRA project. Lists rules of thumb for imaging of use to both beginners and experienced researchers. This volume addresses a wide range of issues in the field of nuclear medicine imaging, with an emphasis on the latest research findings. Initial chapters set the scene by considering the role of imaging in nuclear medicine from the medical perspective and discussing the implications of novel agents and applications for imaging. The physics at the basis of the most modern imaging systems is described, and the reader is introduced to the latest advances in image reconstruction and noise correction. Various novel concepts are then discussed, including those developed within the framework of the EURATOM FP7 MADEIRA research project on the optimization of imaging procedures in order to permit a reduction in the radiation dose to healthy tissues. Advances in quality control and quality assurance are covered, and the book concludes by listing rules of thumb for imaging that will be of use to both beginners and experienced researchers.

  5. Learning chest imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pedrozo Pupo, John C. (ed.) [Magdalena Univ., Santa Maria (Colombia). Respire - Inst. for Respiratory Care

    2013-03-01

    Useful learning tool for practitioners and students. Overview of the imaging techniques used in chest radiology. Aid to the correct interpretation of chest X-ray images. Radiology of the thorax forms an indispensable element of the basic diagnostic process for many conditions and is of key importance in a variety of medical disciplines. This user-friendly book provides an overview of the imaging techniques used in chest radiology and presents numerous instructive case-based images with accompanying explanatory text. A wide range of clinical conditions and circumstances are covered with the aim of enabling the reader to confidently interpret chest images by correctly identifying structures of interest and the causes of abnormalities. This book, which will be an invaluable learning tool, forms part of the Learning Imaging series for medical students, residents, less experienced radiologists, and other medical staff. Learning Imaging is a unique case-based series for those in professional education in general and for physicians in prarticular.

  6. Single-photon imaging

    CERN Document Server

    Seitz, Peter

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncoooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist´s view from different domains to the forthcoming “single-photon imaging” revolution. The various aspects of single-photon imaging are treated by internati...

  7. Synthetic Aperture Compound Imaging

    DEFF Research Database (Denmark)

    Hansen, Jens Munk

    and the limiting factor is the amount of memory IO resources available. An equally high demand for memory throughput is found in the computer gaming industry, where a large part of the processing takes place on the graphics processing unit (GPU). Using the GPU, a framework for synthetic aperture imaging......Medical ultrasound imaging is used for many purposes, e.g. for localizing and classifying cysts, lesions, and other processes. Almost any mass is first observed using B-mode imaging and later classified using e.g. color flow, strain, or attenuation imaging. It is therefore important that the B......-mode images have high contrast. Like all imaging modalities, ultrasound is subject to a number of inherent artifacts that compromise image quality. The most prominent artifact is the degradation by coherent wave interference, known as “speckle”, which gives a granular appearance to an otherwise homogeneous...

  8. [Fundus Autofluorescence Imaging].

    Science.gov (United States)

    Schmitz-Valckenberg, S

    2015-09-01

    Fundus autofluorescence (FAF) imaging allows for non-invasive mapping of changes at the level of the retinal pigment epithelium/photoreceptor complex and of alterations of macular pigment distribution. This imaging method is based on the visualisation of intrinsic fluorophores and may be easily and rapidly used in routine patient care. Main applications include degenerative disorders of the outer retina such as age-related macular degeneration, hereditary and acquired retinal diseases. FAF imaging is particularly helpful for differential diagnosis, detection and extent of involved retinal areas, structural-functional correlations and monitoring of changes over time. Recent developments include - in addition to the original application of short wavelength light for excitation ("blue" FAF imaging) - the use of other wavelength ranges ("green" or "near-infrared" FAF imaging), widefield imaging for visualisation of peripheral retinal areas and quantitative FAF imaging. Georg Thieme Verlag KG Stuttgart · New York.

  9. Imaging in nuclear medicine

    CERN Document Server

    Hoeschen, Christoph

    2013-01-01

    This volume addresses a wide range of issues in the field of nuclear medicine imaging, with an emphasis on the latest research findings. Initial chapters set the scene by considering the role of imaging in nuclear medicine from the medical perspective and discussing the implications of novel agents and applications for imaging. The physics at the basis of the most modern imaging systems is described, and the reader is introduced to the latest advances in image reconstruction and noise correction. Various novel concepts are then discussed, including those developed within the framework of the EURATOM FP7 MADEIRA research project on the optimization of imaging procedures in order to permit a reduction in the radiation dose to healthy tissues. Advances in quality control and quality assurance are covered, and the book concludes by listing rules of thumb for imaging that will be of use to both beginners and experienced researchers.

  10. GOATS Image Projection Component

    Science.gov (United States)

    Haber, Benjamin M.; Green, Joseph J.

    2011-01-01

    When doing mission analysis and design of an imaging system in orbit around the Earth, answering the fundamental question of imaging performance requires an understanding of the image products that will be produced by the imaging system. GOATS software represents a series of MATLAB functions to provide for geometric image projections. Unique features of the software include function modularity, a standard MATLAB interface, easy-to-understand first-principles-based analysis, and the ability to perform geometric image projections of framing type imaging systems. The software modules are created for maximum analysis utility, and can all be used independently for many varied analysis tasks, or used in conjunction with other orbit analysis tools.

  11. Digital cine-imaging

    International Nuclear Information System (INIS)

    Masuda, Kazuhiro

    1992-01-01

    Digitization of fluoroscopic images has been developed for the digital cine imaging system as a result of the computer technology, television technology, and popularization of interventional radiology. Present digital cine imaging system is able to offer images similar to cine film because of the higher operatability and better image quality with the development of interventional radiology. As a result, its higher usefulness for catheter diagnosis examination except for interventional radiology was reported, and the possibility of having filmless cine is close to becoming a reality. However several problems have been pointed out, such as spatial resolution, time resolution, storage and exchangeability of data, disconsolidated viewing functions, etc. Anyhow, digital cine imaging system has some unresolved points and lots the needs to be discussed. The tendency of digitization is the passage of the time and we have to promote a study for more useful digital cine imaging system in team medical treatment which centers on the patients. (author)

  12. Image Sampling with Quasicrystals

    Directory of Open Access Journals (Sweden)

    Mark Grundland

    2009-07-01

    Full Text Available We investigate the use of quasicrystals in image sampling. Quasicrystals produce space-filling, non-periodic point sets that are uniformly discrete and relatively dense, thereby ensuring the sample sites are evenly spread out throughout the sampled image. Their self-similar structure can be attractive for creating sampling patterns endowed with a decorative symmetry. We present a brief general overview of the algebraic theory of cut-and-project quasicrystals based on the geometry of the golden ratio. To assess the practical utility of quasicrystal sampling, we evaluate the visual effects of a variety of non-adaptive image sampling strategies on photorealistic image reconstruction and non-photorealistic image rendering used in multiresolution image representations. For computer visualization of point sets used in image sampling, we introduce a mosaic rendering technique.

  13. Portable Imaging Polarimeter and Imaging Experiments; TOPICAL

    International Nuclear Information System (INIS)

    PHIPPS, GARY S.; KEMME, SHANALYN A.; SWEATT, WILLIAM C.; DESCOUR, M.R.; GARCIA, J.P.; DERENIAK, E.L.

    1999-01-01

    Polarimetry is the method of recording the state of polarization of light. Imaging polarimetry extends this method to recording the spatially resolved state of polarization within a scene. Imaging-polarimetry data have the potential to improve the detection of manmade objects in natural backgrounds. We have constructed a midwave infrared complete imaging polarimeter consisting of a fixed wire-grid polarizer and rotating form-birefringent retarder. The retardance and the orientation angles of the retarder were optimized to minimize the sensitivity of the instrument to noise in the measurements. The optimal retardance was found to be 132(degree) rather than the typical 90(degree). The complete imaging polarimeter utilized a liquid-nitrogen cooled PtSi camera. The fixed wire-grid polarizer was located at the cold stop inside the camera dewar. The complete imaging polarimeter was operated in the 4.42-5(micro)m spectral range. A series of imaging experiments was performed using as targets a surface of water, an automobile, and an aircraft. Further analysis of the polarization measurements revealed that in all three cases the magnitude of circular polarization was comparable to the noise in the calculated Stokes-vector components

  14. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  15. CATE 2016 Indonesia: normalized radial graded filtering, site-to-site image registration, and preliminary results

    Science.gov (United States)

    Jensen, L.; Kovac, S. A.; Hare, H. S.; Mitchell, A. M.; McKay, M. A.; Bosh, R.; Watson, Z.; Penn, M.

    2016-12-01

    An area of the solar corona from 1 out to approximately 2.5 solar radii is currently poorly sampled in astronomy. This is largely due to difficulties inherent in observing the sun from space and from the ground. Specifically focusing on ground based observations, the main problem is scattered light in the Earth's atmosphere and in the telescopes themselves. A total solar eclipse solves this problem by blocking the light from the photosphere of the sun before it enters the atmosphere, reducing the scattered light in the atmosphere by a factor of 10,000. However, using a total solar eclipse introduces another challenge due to the small window of time it provides. At any given location in 2017, the totality will last for only about 2.5 minutes and such a small data set limits the studies that can be done on the inner corona. The Citizen Continental-America Telescopic Eclipse Experiment plans to overcome this issue by taking advantage of America's infrastructure and using 60 identical telescopes to collect continuous data of the solar eclipse as the shadow travels from Oregon to South Carolina. By splicing these data together 90 minutes of one-of-a-kind data can be collected, revealing the dynamics of the inner corona as never seen before. For the 2016 Indonesian total solar eclipse the CATE project collected data using 5 sites along the eclipse path. These data were then used to develop processing programs to use on future data. These processes included site-to-site image registration as well as normalized radial graded filtering of the images. Programs were also developed to begin performing studies on the data including overlapping CATE and LASCO space telescope data for a total coronal image as well as thread tracing routines to quantify direction in the coronal filaments. This work was made possible through the National Solar Observatory Research Experiences for Undergraduates (REU) Program, which is funded by the National Science Foundation (NSF). The NSO

  16. Noise Gating Solar Images

    Science.gov (United States)

    DeForest, Craig; Seaton, Daniel B.; Darnell, John A.

    2017-08-01

    I present and demonstrate a new, general purpose post-processing technique, "3D noise gating", that can reduce image noise by an order of magnitude or more without effective loss of spatial or temporal resolution in typical solar applications.Nearly all scientific images are, ultimately, limited by noise. Noise can be direct Poisson "shot noise" from photon counting effects, or introduced by other means such as detector read noise. Noise is typically represented as a random variable (perhaps with location- or image-dependent characteristics) that is sampled once per pixel or once per resolution element of an image sequence. Noise limits many aspects of image analysis, including photometry, spatiotemporal resolution, feature identification, morphology extraction, and background modeling and separation.Identifying and separating noise from image signal is difficult. The common practice of blurring in space and/or time works because most image "signal" is concentrated in the low Fourier components of an image, while noise is evenly distributed. Blurring in space and/or time attenuates the high spatial and temporal frequencies, reducing noise at the expense of also attenuating image detail. Noise-gating exploits the same property -- "coherence" -- that we use to identify features in images, to separate image features from noise.Processing image sequences through 3-D noise gating results in spectacular (more than 10x) improvements in signal-to-noise ratio, while not blurring bright, resolved features in either space or time. This improves most types of image analysis, including feature identification, time sequence extraction, absolute and relative photometry (including differential emission measure analysis), feature tracking, computer vision, correlation tracking, background modeling, cross-scale analysis, visual display/presentation, and image compression.I will introduce noise gating, describe the method, and show examples from several instruments (including SDO

  17. Transformation invariant image indexing and retrieval for image databases

    NARCIS (Netherlands)

    Gevers, Th.; Smeulders, A.W.M.

    1994-01-01

    This paper presents a novel design of an image database system which supports storage, indexing and retrieval of images by content. The image retrieval methodology is based on the observation that images can be discriminated by the presence of image objects and their spatial relations. Images in the

  18. Introduction to digital image processing

    CERN Document Server

    Pratt, William K

    2013-01-01

    CONTINUOUS IMAGE CHARACTERIZATION Continuous Image Mathematical Characterization Image RepresentationTwo-Dimensional SystemsTwo-Dimensional Fourier TransformImage Stochastic CharacterizationPsychophysical Vision Properties Light PerceptionEye PhysiologyVisual PhenomenaMonochrome Vision ModelColor Vision ModelPhotometry and ColorimetryPhotometryColor MatchingColorimetry ConceptsColor SpacesDIGITAL IMAGE CHARACTERIZATION Image Sampling and Reconstruction Image Sampling and Reconstruction ConceptsMonochrome Image Sampling SystemsMonochrome Image Reconstruction SystemsColor Image Sampling SystemsImage QuantizationScalar QuantizationProcessing Quantized VariablesMonochrome and Color Image QuantizationDISCRETE TWO-DIMENSIONAL LINEAR PROCESSING Discrete Image Mathematical Characterization Vector-Space Image RepresentationGeneralized Two-Dimensional Linear OperatorImage Statistical CharacterizationImage Probability Density ModelsLinear Operator Statistical RepresentationSuperposition and ConvolutionFinite-Area Superp...

  19. On line portal imaging

    International Nuclear Information System (INIS)

    Munro, Peter

    1997-01-01

    Purpose/Objective: The purpose of this presentation is to examine the various imaging devices that have been developed for portal imaging, describe some of the image registration methods that have been developed to determine geometric errors quantitatively, and discuss how portal imaging has been incorporated into clinical practice. Discussion: Verification of patient positioning has always been an important aspect of external beam radiation therapy. Over the past decade many portal imaging devices have been developed by individual investigators and most accelerator manufacturers now offer 'on-line' portal imaging systems. The commercial devices include T.V. camera-based systems, liquid ionisation chamber systems, and shortly, flat panel systems. The characteristics of these imaging systems will be discussed. In addition, other approaches such as the use of kilovoltage x-ray sources, video monitoring, and ultrasound have been proposed for improving patient positioning. Some of the advantages of these approaches will be discussed. One of the major advantages of on-line portal imaging is that many quantitative techniques have been developed to detect errors in patient positioning. The general approach is to register anatomic structures on a portal image with the same structures on a digitized simulator film. Once the anatomic structures have been registered, any discrepancies in the position of the patient can be identified. One problem is finding a common frame of reference for the simulator and portal images, since the location of the radiation field within the pixel matrix may differ for the two images. As a result, a common frame of reference has to be established before the anatomic structures in the images can be registered - generally by registering radiation field edges identified in the simulator and portal images. In addition, distortions in patient geometry or rotations out of the image plane can confound the image registration techniques. Despite the

  20. Diagnostic image workstations ofr PACS

    International Nuclear Information System (INIS)

    Meyer-Ebrecht, D.; Fasel, B.; Dahm, M.; Kaupp, A.; Schilling, R.

    1990-01-01

    Image workstations will be the 'window' to the complex infrastructure of PACS with its intertwined image modalities (image sources, image data bases and image processing devices) and data processing modalities (patient data bases, departmental and hospital information systems). They will serve for user-to-system dialogues, image display and local processing of data as well as images. Their hardware and software structures have to be optimized towards an efficient throughput and processing of image data. (author). 10 refs

  1. Image forming apparatus

    DEFF Research Database (Denmark)

    2005-01-01

    An image H(x, y) for displaying a target image G(x, y) is displayed on a liquid-crystal display panel and illumination light from an illumination light source is made to pass therethrough to form an image on a PALSLM. Read light hv is radiated to the PALSLM and a phase-modulated light image alpha...... (x, y) read out of the PALSLM is subjected to Fourier transform by a lens. A phase contrast filter gives a predetermined phase shift to only the zero-order light component of Fourier light image alpha f(x, y). The phase-shifted light image is subjected to inverse Fourier transform by a lens...... to project an output image O(x, y) to an output plane. A light image O'(x, y) branched by a beam sampler is picked up by a pickup device and an evaluation value calculating unit evaluates conformity between the image O(x, y) and the image G(x, y).; A control unit performs feedback control of optical...

  2. Imaging the trigeminal nerve

    International Nuclear Information System (INIS)

    Borges, Alexandra; Casselman, Jan

    2010-01-01

    Of all cranial nerves, the trigeminal nerve is the largest and the most widely distributed in the supra-hyoid neck. It provides sensory input from the face and motor innervation to the muscles of mastication. In order to adequately image the full course of the trigeminal nerve and its main branches a detailed knowledge of neuroanatomy and imaging technique is required. Although the main trunk of the trigeminal nerve is consistently seen on conventional brain studies, high-resolution tailored imaging is mandatory to depict smaller nerve branches and subtle pathologic processes. Increasing developments in imaging technique made possible isotropic sub-milimetric images and curved reconstructions of cranial nerves and their branches and led to an increasing recognition of symptomatic trigeminal neuropathies. Whereas MRI has a higher diagnostic yield in patients with trigeminal neuropathy, CT is still required to demonstrate the bony anatomy of the skull base and is the modality of choice in the context of traumatic injury to the nerve. Imaging of the trigeminal nerve is particularly cumbersome as its long course from the brainstem nuclei to the peripheral branches and its rich anastomotic network impede, in most cases, a topographic approach. Therefore, except in cases of classic trigeminal neuralgia, in which imaging studies can be tailored to the root entry zone, the full course of the trigeminal nerve has to be imaged. This article provides an update in the most recent advances on MR imaging technique and a segmental imaging approach to the most common pathologic processes affecting the trigeminal nerve.

  3. Imaging the trigeminal nerve

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Alexandra [Radiology Department, Instituto Portugues de Oncologia Francisco Gentil, Centro de Lisboa, Rua Prof. Lima Basto, 1093, Lisboa (Portugal)], E-mail: borgalexandra@gmail.com; Casselman, Jan [Department of Radiology, A. Z. St Jan Brugge and A. Z. St Augustinus Antwerpen Hospitals (Belgium)

    2010-05-15

    Of all cranial nerves, the trigeminal nerve is the largest and the most widely distributed in the supra-hyoid neck. It provides sensory input from the face and motor innervation to the muscles of mastication. In order to adequately image the full course of the trigeminal nerve and its main branches a detailed knowledge of neuroanatomy and imaging technique is required. Although the main trunk of the trigeminal nerve is consistently seen on conventional brain studies, high-resolution tailored imaging is mandatory to depict smaller nerve branches and subtle pathologic processes. Increasing developments in imaging technique made possible isotropic sub-milimetric images and curved reconstructions of cranial nerves and their branches and led to an increasing recognition of symptomatic trigeminal neuropathies. Whereas MRI has a higher diagnostic yield in patients with trigeminal neuropathy, CT is still required to demonstrate the bony anatomy of the skull base and is the modality of choice in the context of traumatic injury to the nerve. Imaging of the trigeminal nerve is particularly cumbersome as its long course from the brainstem nuclei to the peripheral branches and its rich anastomotic network impede, in most cases, a topographic approach. Therefore, except in cases of classic trigeminal neuralgia, in which imaging studies can be tailored to the root entry zone, the full course of the trigeminal nerve has to be imaged. This article provides an update in the most recent advances on MR imaging technique and a segmental imaging approach to the most common pathologic processes affecting the trigeminal nerve.

  4. Introduction to computer image processing

    Science.gov (United States)

    Moik, J. G.

    1973-01-01

    Theoretical backgrounds and digital techniques for a class of image processing problems are presented. Image formation in the context of linear system theory, image evaluation, noise characteristics, mathematical operations on image and their implementation are discussed. Various techniques for image restoration and image enhancement are presented. Methods for object extraction and the problem of pictorial pattern recognition and classification are discussed.

  5. Enhancement of blurred image portions

    NARCIS (Netherlands)

    2008-01-01

    This invention relates to a method for image enhancement, comprising a first step ( 41 ) of distinguishing blurred and non-blurred image portions of an input image, and a second step ( 42 ) of enhancing at least one of said blurred image portions of said input image to produce an output image. Said

  6. [Imaging center - optimization of the imaging process].

    Science.gov (United States)

    Busch, H-P

    2013-04-01

    Hospitals around the world are under increasing pressure to optimize the economic efficiency of treatment processes. Imaging is responsible for a great part of the success but also of the costs of treatment. In routine work an excessive supply of imaging methods leads to an "as well as" strategy up to the limit of the capacity without critical reflection. Exams that have no predictable influence on the clinical outcome are an unjustified burden for the patient. They are useless and threaten the financial situation and existence of the hospital. In recent years the focus of process optimization was exclusively on the quality and efficiency of performed single examinations. In the future critical discussion of the effectiveness of single exams in relation to the clinical outcome will be more important. Unnecessary exams can be avoided, only if in addition to the optimization of single exams (efficiency) there is an optimization strategy for the total imaging process (efficiency and effectiveness). This requires a new definition of processes (Imaging Pathway), new structures for organization (Imaging Center) and a new kind of thinking on the part of the medical staff. Motivation has to be changed from gratification of performed exams to gratification of process quality (medical quality, service quality, economics), including the avoidance of additional (unnecessary) exams. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Image forming apparatus

    DEFF Research Database (Denmark)

    2005-01-01

    (x, y) read out of the PALSLM is subjected to Fourier transform by a lens. A phase contrast filter gives a predetermined phase shift to only the zero-order light component of Fourier light image alpha f(x, y). The phase-shifted light image is subjected to inverse Fourier transform by a lens...... to project an output image O(x, y) to an output plane. A light image O'(x, y) branched by a beam sampler is picked up by a pickup device and an evaluation value calculating unit evaluates conformity between the image O(x, y) and the image G(x, y).; A control unit performs feedback control of optical...

  8. Second harmonic generation imaging

    CERN Document Server

    2013-01-01

    Second-harmonic generation (SHG) microscopy has shown great promise for imaging live cells and tissues, with applications in basic science, medical research, and tissue engineering. Second Harmonic Generation Imaging offers a complete guide to this optical modality, from basic principles, instrumentation, methods, and image analysis to biomedical applications. The book features contributions by experts in second-harmonic imaging, including many pioneering researchers in the field. Written for researchers at all levels, it takes an in-depth look at the current state of the art and possibilities of SHG microscopy. Organized into three sections, the book: Provides an introduction to the physics of the process, step-by-step instructions on how to build an SHG microscope, and comparisons with related imaging techniques Gives an overview of the capabilities of SHG microscopy for imaging tissues and cells—including cell membranes, muscle, collagen in tissues, and microtubules in live cells—by summarizing experi...

  9. Video Toroid Cavity Imager

    Energy Technology Data Exchange (ETDEWEB)

    Gerald, Rex E. II; Sanchez, Jairo; Rathke, Jerome W.

    2004-08-10

    A video toroid cavity imager for in situ measurement of electrochemical properties of an electrolytic material sample includes a cylindrical toroid cavity resonator containing the sample and employs NMR and video imaging for providing high-resolution spectral and visual information of molecular characteristics of the sample on a real-time basis. A large magnetic field is applied to the sample under controlled temperature and pressure conditions to simultaneously provide NMR spectroscopy and video imaging capabilities for investigating electrochemical transformations of materials or the evolution of long-range molecular aggregation during cooling of hydrocarbon melts. The video toroid cavity imager includes a miniature commercial video camera with an adjustable lens, a modified compression coin cell imager with a fiat circular principal detector element, and a sample mounted on a transparent circular glass disk, and provides NMR information as well as a video image of a sample, such as a polymer film, with micrometer resolution.

  10. Introducing Zoomify Image

    Directory of Open Access Journals (Sweden)

    Adam Smith

    2007-03-01

    Full Text Available Zoomify Image is a mature product for easily publishing large, high-resolution images on the Web. End users view these images with existing Webbrowser software as quickly as they do normal, downsampled images. A Flash-based Zoomifyer client asynchronously streams image data to the Web browser as needed, resulting in response times approaching those of desktop applications using minimal bandwidth. The author, a librarian at Cornell University and the principal architect of a small, open-source company, worked closely with Zoomify to produce a cross-platform, opensource implementation of that company’s image-processing software and discusses how to easily deploy the product into a widely used Webpublishing environment. Limitations are also discussed as are areas of improvement and alternatives.

  11. Applications of optical imaging

    International Nuclear Information System (INIS)

    Schellenberger, E.

    2005-01-01

    Optical imaging in the form of near infrared fluorescence and bioluminescence has proven useful for a wide range of applications in the field of molecular imaging. Both techniques provide a high sensitivity (in the nanomolar range), which is of particular importance for molecular imaging. Imaging with near infrared fluorescence is especially cost-effective and can be performed, in contrast to radioactivity-based methods, with fluorescence dyes that remain stable for months. The most important advantage of bioluminescence, in turn, is the lack of background signal. Although molecular imaging with these techniques is still in the experimental phase, an application of near infrared fluorescence is already foreseeable for the imaging of superficial structures. (orig.)

  12. Imaging arrangement and microscope

    Science.gov (United States)

    Pertsinidis, Alexandros; Chu, Steven

    2015-12-15

    An embodiment of the present invention is an imaging arrangement that includes imaging optics, a fiducial light source, and a control system. In operation, the imaging optics separate light into first and second tight by wavelength and project the first and second light onto first and second areas within first and second detector regions, respectively. The imaging optics separate fiducial light from the fiducial light source into first and second fiducial light and project the first and second fiducial light onto third and fourth areas within the first and second detector regions, respectively. The control system adjusts alignment of the imaging optics so that the first and second fiducial light projected onto the first and second detector regions maintain relatively constant positions within the first and second detector regions, respectively. Another embodiment of the present invention is a microscope that includes the imaging arrangement.

  13. The Generalized Image

    DEFF Research Database (Denmark)

    Schmidt, Ulrik

    2017-01-01

    The dichotomy between the figurative and the abstract has often been evoked as a key element in the understanding of the modern image, as it was the case, for example, in influential art historians such as Wilhelm Worringer and Clement Greenberg. However, if such a rigid opposition between...... the abstract and figurative has ever been qualified, an unlimited number of images after 1900 – whether painted, printed or screen-based – have significantly obscured any clear distinction between the two. Hence, if one wishes to understand the very nature of modern images it is indispensable to ask what...... it could mean to conceive of images beyond the opposition between the abstract and the figurative: How could we think of images that are neither figurative nor abstract, or perhaps are both at the same time? How could we think of images that are not either signifying and representational or non...

  14. Oncology PET imaging

    International Nuclear Information System (INIS)

    Inubushi, Masayuki

    2014-01-01

    At the beginning of this article, likening medical images to 'Where is Waldo?' I indicate the concept of diagnostic process of PET/CT imaging, so that medical physics specialists could understand the role of each imaging modality and infer our distress for image diagnosis. Then, I state the present situation of PET imaging and the basics (e.g. health insurance coverage, clinical significance, principle, protocol, and pitfall) of oncology FDG-PET imaging which accounts for more than 99% of all clinical PET examinations in Japan. Finally, I would like to give a wishful prospect of oncology PET that will expand to be more cancer-specific in order to assess therapeutic effects of emerging molecular targeted drugs targeting the 'hallmarks of cancer'. (author)

  15. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  16. Phase Contrast Imaging

    DEFF Research Database (Denmark)

    1996-01-01

    The invention relates to a method and a system for synthesizing a prescribed intensity pattern based on phase contrast imaging that is not based on the assumption of prior art methods that the pahase shift phi is less than 1 radian. An improved method based on a simple imaging operation...... phasors attain predetermined values for predetermined spatial frequencies, and the phasor value of the specific resolution element of the spatial phase mask corresponds to a distinct intensity level of the image of the resolution element in the intensity pattern, and a spatial phase filter for phase...... shifting of a part of the electromagntic radiation, in combination with an imaging system for generation of the intensity pattern by interference in the image plane of the imaging system between the part of the electromagnetic raidation that has been phase shifted by the phase filter and the remaining part...

  17. Correlated diffusion imaging

    International Nuclear Information System (INIS)

    Wong, Alexander; Glaister, Jeffrey; Cameron, Andrew; Haider, Masoom

    2013-01-01

    Prostate cancer is one of the leading causes of cancer death in the male population. Fortunately, the prognosis is excellent if detected at an early stage. Hence, the detection and localization of prostate cancer is crucial for diagnosis, as well as treatment via targeted focal therapy. New imaging techniques can potentially be invaluable tools for improving prostate cancer detection and localization. In this study, we introduce a new form of diffusion magnetic resonance imaging called correlated diffusion imaging, where the tissue being imaged is characterized by the joint correlation of diffusion signal attenuation across multiple gradient pulse strengths and timings. By taking into account signal attenuation at different water diffusion motion sensitivities, correlated diffusion imaging can provide improved delineation between cancerous tissue and healthy tissue when compared to existing diffusion imaging modalities. Quantitative evaluation using receiver operating characteristic (ROC) curve analysis, tissue class separability analysis, and visual assessment by an expert radiologist were performed to study correlated diffusion imaging for the task of prostate cancer diagnosis. These results are compared with that obtained using T2-weighted imaging and standard diffusion imaging (via the apparent diffusion coefficient (ADC)). Experimental results suggest that correlated diffusion imaging provide improved delineation between healthy and cancerous tissue and may have potential as a diagnostic tool for cancer detection and localization in the prostate gland. A new form of diffusion magnetic resonance imaging called correlated diffusion imaging (CDI) was developed for the purpose of aiding radiologists in cancer detection and localization in the prostate gland. Preliminary results show CDI shows considerable promise as a diagnostic aid for radiologists in the detection and localization of prostate cancer

  18. Molecular imaging in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Schober, Otmar; Riemann, Burkhard (eds.) [Universitaetsklinikum Muenster (Germany). Klinik fuer Nuklearmedizin

    2013-02-01

    Considers in detail all aspects of molecular imaging in oncology, ranging from basic research to clinical applications in the era of evidence-based medicine. Examines technological issues and probe design. Discusses preclinical studies in detail, with particular attention to multimodality imaging. Presents current clinical use of PET/CT, SPECT/CT, and optical imagingWritten by acknowledged experts. The impact of molecular imaging on diagnostics, therapy, and follow-up in oncology is increasing significantly. The process of molecular imaging includes key biotarget identification, design of specific molecular imaging probes, and their preclinical evaluation, e.g., in vivo using small animal studies. A multitude of such innovative molecular imaging probes have already entered clinical diagnostics in oncology. There is no doubt that in future the emphasis will be on multimodality imaging in which morphological, functional, and molecular imaging techniques are combined in a single clinical investigation that will optimize diagnostic processes. This handbook addresses all aspects of molecular imaging in oncology, ranging from basic research to clinical applications in the era of evidence-based medicine. The first section is devoted to technology and probe design, and examines a variety of PET and SPECT tracers as well as multimodality probes. Preclinical studies are then discussed in detail, with particular attention to multimodality imaging. In the third section, diverse clinical applications are presented, and the book closes by looking at future challenges. This handbook will be of value to all who are interested in the revolution in diagnostic oncology that is being brought about by molecular imaging.

  19. MRI: Imaging of stomach

    International Nuclear Information System (INIS)

    Lam, W. W. M; Lee, J. S. W.; Ho, G.

    2007-01-01

    Full text: The study is to determine the optimal MRI bowel preparation regime for visualization of the stomach anatomy, Eight healthy volunteers were asked to take water, 75% barium and blueberry juice. The image quality and tolerance of different stomach distension regime were evaluated. Blueberry juice gave the best distension, but the signal intensity was not very homogeneous. Taking into account the image quality, tolerability and adverse effects, it is concluded that water is the most desirable oral contrast for MR stomach imaging

  20. Investigations of image fusion

    Science.gov (United States)

    Zhang, Zhong

    1999-12-01

    The objective of image fusion is to combine information from multiple images of the same scene. The result of image fusion is a single image which is more suitable for the purpose of human visual perception or further image processing tasks. In this thesis, a region-based fusion algorithm using the wavelet transform is proposed. The identification of important features in each image, such as edges and regions of interest, are used to guide the fusion process. The idea of multiscale grouping is also introduced and a generic image fusion framework based on multiscale decomposition is studied. The framework includes all of the existing multiscale-decomposition- based fusion approaches we found in the literature which did not assume a statistical model for the source images. Comparisons indicate that our framework includes some new approaches which outperform the existing approaches for the cases we consider. Registration must precede our fusion algorithms. So we proposed a hybrid scheme which uses both feature-based and intensity-based methods. The idea of robust estimation of optical flow from time- varying images is employed with a coarse-to-fine multi- resolution approach and feature-based registration to overcome some of the limitations of the intensity-based schemes. Experiments show that this approach is robust and efficient. Assessing image fusion performance in a real application is a complicated issue. In this dissertation, a mixture probability density function model is used in conjunction with the Expectation- Maximization algorithm to model histograms of edge intensity. Some new techniques are proposed for estimating the quality of a noisy image of a natural scene. Such quality measures can be used to guide the fusion. Finally, we study fusion of images obtained from several copies of a new type of camera developed for video surveillance. Our techniques increase the capability and reliability of the surveillance system and provide an easy way to obtain 3-D