  1. Turbofan gas turbine engine with variable fan outlet guide vanes

    Science.gov (United States)

    Wood, Peter John (Inventor); LaChapelle, Donald George (Inventor); Grant, Carl (Inventor); Zenon, Ruby Lasandra (Inventor); Mielke, Mark Joseph (Inventor)

    2010-01-01

    A turbofan gas turbine engine includes a forward fan section with a row of fan rotor blades, a core engine, and a fan bypass duct downstream of the forward fan section and radially outwardly of the core engine. The forward fan section has only a single stage of variable fan guide vanes which are variable fan outlet guide vanes downstream of the forward fan rotor blades. An exemplary embodiment of the engine includes an afterburner downstream of the fan bypass duct between the core engine and an exhaust nozzle. The variable fan outlet guide vanes are operable to pivot from a nominal OGV position at take-off to an open OGV position at a high flight Mach Number which may be in a range of between about 2.5-4+. Struts extend radially across a radially inwardly curved portion of a flowpath of the engine between the forward fan section and the core engine.

  2. The impact of inlet angle and outlet angle of guide vane on pump in reversal based hydraulic turbine performance

    International Nuclear Information System (INIS)

    Shi, F X; Yang, J H; Wang, X H; Zhang, R H; Li, C E

    2012-01-01

    In this paper, in order to research the impact of inlet angle and outlet angle of guide vane on hydraulic turbine performance, a centrifugal pump in reversal is adopted as turbine. A numerical simulation method is adopted for researching outer performance and flow field of turbine. The results show: inlet angle has a crucial role to turbine, to the same flow, there is a noticeable decline for the efficiency and head of turbine with the inlet angle increases. At the best efficiency point(EFP),to a same inlet angle, when the inlet angle greater than inlet angle, velocity circulation in guide vane outlet decreases, which lead the efficiency of turbine to reduce, Contrarily, the efficiency rises. With the increase of inlet angle and outlet angle, the EFP moves to the big flow area and the uniformity of pressure distribution becomes worse. The paper indicates that the inlet angle and outlet angle have great impact on the turbine performance, and the best combination exists for the inlet angle and outlet angle of the guide vane.

  3. Interaction of impeller and guide vane in a series-designed axial-flow pump

    International Nuclear Information System (INIS)

    Kim, S; Choi, Y S; Lee, K Y; Kim, J H

    2012-01-01

    In this paper, the interaction of the impeller and guide vane in a series-designed axial-flow pump was examined through the implementation of a commercial CFD code. The impeller series design refers to the general design procedure of the base impeller shape which must satisfy the various flow rate and head requirements by changing the impeller setting angle and number of blades of the base impeller. An arc type meridional shape was used to keep the meridional shape of the hub and shroud with various impeller setting angles. The blade angle and the thickness distribution of the impeller were designed as an NACA airfoil type. In the design of the guide vane, it was necessary to consider the outlet flow condition of the impeller with the given setting angle. The meridional shape of the guide vane were designed taking into consideration the setting angle of the impeller, and the blade angle distribution of the guide vane was determined with a traditional design method using vane plane development. In order to achieve the optimum impeller design and guide vane, three-dimensional computational fluid dynamics and the DOE method were applied. The interaction between the impeller and guide vane with different combination set of impeller setting angles and number of impeller blades was addressed by analyzing the flow field of the computational results.

  4. Effect of spacer grid mixing vanes on coolant outlet temperature distribution

    Energy Technology Data Exchange (ETDEWEB)

    Raemae, Tommi; Lahtinen, Tuukka; Brandt, Tellervo; Toppila, Timo [Fortum Power and Heat, Fortum (Finland). Nuclear Competence Center

    2012-08-15

    In Loviisa VVER-440-type NPP the coolant outlet temperature of the hot subchannel is constantly monitored during the operation. According to the authority requirement the maximum subchannel outlet temperature must not exceed the saturation temperature. Coolant temperature distribution inside the fuel assembly is affected by the efficiency of the coolant mixing. In order to enhance the coolant mixing the fuel manufacturer is introducing the additional mixing vanes on the fuel bundle spacer grids. In the paper the effect of the different mixing vane modifications is studied with computational fluid dynamics (CFD) simulation. Goal of the modelling is to find vane modifications with which sufficient mixing is reached with acceptable increase in the spacer grid pressure loss. The results of the studies are discussed in the paper. (orig.)

  5. Design and experimental validation of the inlet guide vane system of a mini hydraulic bulb-turbine

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, L.M.C. [Department of Mechanical Engineering, Escola Superior de Tecnologia de Setubal, Polytechnic Institute of Setubal, Campus do IPS, Estefanilha, 2910-761 Setubal (Portugal); IDMEC, Instituto Superior Tecnico, Technical University of Lisbon, Av. Rovisco Pais,1049-001 Lisboa (Portugal); Gato, L.M.C.; Falcao, A.F.O. [IDMEC, Instituto Superior Tecnico, Technical University of Lisbon, Av. Rovisco Pais,1049-001 Lisboa (Portugal)

    2010-09-15

    The paper presents a fast design method for the inlet guide vanes of low-cost mini hydraulic bulb turbines. The guide vanes are positioned between two conical surfaces with a common vertex and have constant thickness distribution, except close to the leading and the trailing edges. The conical-walled inlet guide vane row is designed using a quasi-three-dimensional calculation method, by prescribing the angular-momentum distribution along the span at the outlet section of the guide vanes. The meridional through-flow is computed by a streamline curvature method and the blade-to-blade flow by a singularity surface method. The stagger angle and the vane camber are computed to fulfil the required design circulation and zero-incidence flow at the leading edge. The final vane shape is a single-curvature surface with straight leading and trailing edges. To validate the design method, a conical-walled inlet guide vane row nozzle-model with six fixed vanes was designed, manufactured and tested in an airflow rig. Traversing measurements along the circumferential and radial directions were made with a five-hole probe. The experimental results are compared with the prescribed design conditions and with numerical results from the three-dimensional inviscid and viscous flow computed with the FLUENT code. (author)

  6. Velocity and pressure measurements in guide vane clearance gap of a low specific speed Francis turbine

    Science.gov (United States)

    Thapa, B. S.; Dahlhaug, O. G.; Thapa, B.

    2016-11-01

    In Francis turbine, a small clearance gap between the guide vanes and the cover plates is usually required to pivot guide vanes as a part of governing system. Deflection of cover plates and erosion of mating surfaces causes this gap to increase from its design value. The clearance gap induces the secondary flow in the distributor system. This effects the main flow at the runner inlet, which causes losses in efficiency and instability. A guide vane cascade of a low specific speed Francis turbine has been developed for experimental investigations. The test setup is able to produce similar velocity distributions at the runner inlet as that of a reference prototype turbine. The setup is designed for particle image velocimetry (PIV) measurements from the position of stay vane outlet to the position of runner inlet. In this study, velocity and pressure measurements are conducted with 2 mm clearance gap on one side of guide vane. Leakage flow is observed and measured together with pressure measurements. It is concluded that the leakage flow behaves as a jet and mixes with the main flow in cross-wise direction and forms a vortex filament. This causes non-uniform inlet flow conditions at runner blades.

  7. ESRC guide vanes of hydraulic turbine for Three Gorges project

    Directory of Open Access Journals (Sweden)

    Rui CHEN

    2005-05-01

    Full Text Available The mechanical properties and internal quality of low carbon martensite Electroslag Remelting Casting (ESRCstainless steel castings are superior to that of sand casting ones. The key technologies for the equipments and ESRC processes have been resolved during the experimental research period of guide vanes of hydraulic turbines for Three Gorges project. And ESRC guide vanes of hydraulic turbines for Three Gorges project have been produced successfully.

  8. Fluid-structure coupling in the guide vanes cascade of a pump-turbine scale model

    International Nuclear Information System (INIS)

    Roth, S; Hasmatuchi, V; Botero, F; Farhat, M; Avellan, F

    2010-01-01

    The present study concerns fluid-structure coupling phenomena occurring in a guide vane cascade of a pump-turbine scale model placed in the EPFL PF3 test rig. An advanced instrument set is used to monitor both vibrating structures and the surrounding flow. The paper highlights the interaction between vibrating guide vanes and the flow behavior. The pressure fluctuations in the stay vanes region are found to be strongly influenced by the amplitude of the vibrating guide vanes. Moreover, the flow induces different hydrodynamic damping on the vibrating guide vanes depending on the operating point of the pump-turbine.

  9. Fluid-structure coupling in the guide vanes cascade of a pump-turbine scale model

    Science.gov (United States)

    Roth, S.; Hasmatuchi, V.; Botero, F.; Farhat, M.; Avellan, F.

    2010-08-01

    The present study concerns fluid-structure coupling phenomena occurring in a guide vane cascade of a pump-turbine scale model placed in the EPFL PF3 test rig. An advanced instrument set is used to monitor both vibrating structures and the surrounding flow. The paper highlights the interaction between vibrating guide vanes and the flow behavior. The pressure fluctuations in the stay vanes region are found to be strongly influenced by the amplitude of the vibrating guide vanes. Moreover, the flow induces different hydrodynamic damping on the vibrating guide vanes depending on the operating point of the pump-turbine.

  10. Characterization of Rotating Detonation Engine Exhaust Through Nozzle Guide Vanes

    Science.gov (United States)

    2013-03-21

    ENY/13-M09 Abstract A Rotating Detonation Engine ( RDE ) has higher thermal efficiencies in comparison to its traditional gas turbine counterparts. Thus...as budgets decrease and fuel costs increase, RDEs have become a research focus for the United States Air Force. An integration assembly for attaching...the first Nozzle Guide Vane (NGV) section from a T63 gas turbine engine to a 6 inch diameter RDE was designed and built for this study. Pressure

  11. Automatic efficiency optimization of an axial compressor with adjustable inlet guide vanes

    Science.gov (United States)

    Li, Jichao; Lin, Feng; Nie, Chaoqun; Chen, Jingyi

    2012-04-01

    The inlet attack angle of rotor blade reasonably can be adjusted with the change of the stagger angle of inlet guide vane (IGV); so the efficiency of each condition will be affected. For the purpose to improve the efficiency, the DSP (Digital Signal Processor) controller is designed to adjust the stagger angle of IGV automatically in order to optimize the efficiency at any operating condition. The A/D signal collection includes inlet static pressure, outlet static pressure, outlet total pressure, rotor speed and torque signal, the efficiency can be calculated in the DSP, and the angle signal for the stepping motor which control the IGV will be sent out from the D/A. Experimental investigations are performed in a three-stage, low-speed axial compressor with variable inlet guide vanes. It is demonstrated that the DSP designed can well adjust the stagger angle of IGV online, the efficiency under different conditions can be optimized. This establishment of DSP online adjustment scheme may provide a practical solution for improving performance of multi-stage axial flow compressor when its operating condition is varied.

  12. Effect of Guide Vane Clearance Gap on Francis Turbine Performance

    Directory of Open Access Journals (Sweden)

    Ravi Koirala

    2016-04-01

    Full Text Available Francis turbine guide vanes have pivoted support with external control mechanism, for conversion of pressure to kinetic energy and to direct them to runner vanes. This movement along the support is dependent on variation of load and flow (operating conditions. Small clearance gaps between facing plates and the upper and lower guide vane tips are available to aid this movement, through which leakage flow occurs. This secondary flow disturbs the main flow stream, resulting performance loss. Additionally, these increased horseshoe vortex, in presence of sand, when crosses through the gaps, both the surfaces are eroded. This causes further serious effect on performance and structural property by increasing gaps. This paper discusses the observation of the severity in hydropower plants and effect of clearance gaps on general performance of the Francis turbine through computational methods. It also relates the primary result with the empirical relation for leakage flow prediction. Additionally, a possible method to computationally estimate thickness depletion has also been presented. With increasing clearance gap, leakage increases, which lowers energy conversion and turbine efficiency along with larger secondary vortex.

  13. A Straight-bladed Vertical Axis Wind Turbine with a Directed Guide Vane Row-Effect of Guide Vane Geometry on the Performance-

    Institute of Scientific and Technical Information of China (English)

    Manabu TAKAO; Hideki KUMA; Takao MAEDA; Yasunari KAMADA; Michiaki OKI; Atsushi MINODA

    2009-01-01

    The objective of this study is to show the effect of guide vane geometry on the performance. In order to over-come the disadvantages of vertical axis wind turbine, a straight-bladed vertical axis wind turbine (S-VAWT) with a directed guide vane row has been proposed and tested by the authors. According to previous studies, it was clarified that the performance of the turbine can be improved by means of the directed guide vane row. However, the guide vane geometry of S-VAWT has not been optimized so far. In order to clarify the effect of guide vane geometry, the effects of setting angle and gap between rotor blade and guide vane on power coefficient and start-ing characteristic were investigated in the experiments. The experimental study of the proposed wind turbine was carded out by a wind tunnel. The wind tunnel with a diameter of 1.8m is open jet type. The wind velocity is 8 m/s in the experiments. The rotor has three straight blades with a profile of NACA0018 and a chord length of 100 mm, a diameter of 0.6 m and a blade height of 0.7 m. The guide vane row consists of 3 arc plates.

  14. Investigation of Blade-row Flow Distributions in Axial-flow-compressor Stage Consisting of Guide Vanes and Rotor-blade Row

    Science.gov (United States)

    Mahoney, John J; Dugan, Paul D; Budinger, Raymond E; Goelzer, H Fred

    1950-01-01

    A 30-inch tip-diameter axial-flow compressor stage was investigated with and without rotor to determine individual blade-row performance, interblade-row effects, and outer-wall boundary-layer conditions. Velocity gradients at guide-vane outlet without rotor approximated design assumptions, when the measured variation of leaving angle was considered. With rotor in operation, Mach number and rotor-blade effects changed flow distribution leaving guide vanes and invalidated design assumption of radial equilibrium. Rotor-blade performance correlated interpolated two-dimensional results within 2 degrees, although tip stall was indicated in experimental and not two-dimensional results. Boundary-displacement thickness was less than 1.0 and 1.5 percent of passage height after guide vanes and after rotor, respectively, but increased rapidly after rotor when tip stall occurred.

  15. Research and development on the hydraulic design system of the guide vanes of multistage centrifugal pumps

    International Nuclear Information System (INIS)

    Zhang, Q H; Xu, Y; Shi, W D; Lu, W G

    2012-01-01

    To improve the hydraulic design accuracy and efficiency of the guide vanes of the multistage centrifugal pumps, four different-structured guide vanes are investigated, and the design processes of those systems are established. The secondary development platforms of the ObjectArx2000 and the UG/NX OPEN are utilized to develop the hydraulic design systems of the guide vanes. The error triangle method is adopted to calculate the coordinates of the vanes, the profiles of the vanes are constructed by Bezier curves, and then the curves of the flow areas along the flow-path are calculated. Two-dimensional and three-dimensional hydraulic models can be developed by this system.

  16. Numerical prediction for effects of guide vane blade numbers on hydraulic turbine performance

    International Nuclear Information System (INIS)

    Shi, F X; Yang, J H; Wang, X H; Li, C E

    2013-01-01

    Using unstructured hybrid grid technique and SIMPLEC algorithm,a general three-dimensional simulation based on Reynolds Navier- stocks in multiple reference frames and the RNG k-ε turbulence model, is presented for the reversal centrifugal pump (PAT) with a guide vane. Four different schemes are designed by a change of the number of guide vane blade of PAT. The inner flow field in every scheme is simulated, accordingly, the external characteristic and static pressure distribution in flow field in PAT is obtained. The results obtained show that the efficiency can be improved by adding a guide vane for the PAT, besides, the high efficiency area is wider than before. Guide blade numbers changed, external characteristics of turbine changed, and the external characteristic changed. The optimal value is existent for the guide vane blade number, which has a great impact on the distribution of pressure in runner inlet

  17. Suppression of tonal noise in a centrifugal fan using guide vanes

    Science.gov (United States)

    Paramasivam, Kishokanna; Rajoo, Srithar; Romagnoli, Alessandro

    2015-11-01

    This paper presents the work aiming for tonal noise reduction in a centrifugal fan. In previous studies, it is well documented that tonal noise is the dominant noise source generated in centrifugal fans. Tonal noise is generated due to the aerodynamic interaction between the rotating impeller and stationary diffuser vanes. The generation of tonal noise is related to the pressure fluctuation at the leading edge of the stationary vane. The tonal noise is periodic in time which occurs at the blade passing frequency (BPF) and its harmonics. Much of previous studies, have shown that the stationary vane causes the tonal noise and generation of non-rotational turbulent noise. However, omitting stationary vanes will lead to the increase of non-rotational turbulent noise resulted from the high velocity of the flow leaving the impeller. Hence in order to reduce the tonal noise and the non-rotational noise, guide vanes were designed as part of this study to replace the diffuser vanes, which were originally used in the chosen centrifugal fan. The leading edge of the guide vane is tapered. This modification reduces the strength of pressure fluctuation resulting from the interaction between the impeller outflow and stationary vane. The sound pressure level at blade passing frequency (BPF) is reduced by 6.8 dB, the 2nd BPF is reduced by 4.1 dB and the 3rd BPF reduced by about 17.5 dB. The overall reduction was 0.9 dB. The centrifugal fan with tapered guide vanes radiates lower tonal noise compared to the existing diffuser vanes. These reductions are achieved without compromising the performance of the centrifugal fan. The behavior of the fluid flow was studied using computational fluid dynamics (CFD) tools and the acoustics characteristics were determined through experiments in an anechoic chamber.

  18. Numerical and experimental study of the leakage flow in guide vanes with different hydrofoils

    Directory of Open Access Journals (Sweden)

    Sailesh Chitrakar

    2017-07-01

    Full Text Available Clearance gaps between guide vanes and cover plates of Francis turbines tend to increase in size due to simultaneous effect of secondary flow and erosion in sediment affected hydropower plants. The pressure difference between the two sides of the guide vane induces leakage flow through the gap. This flow enters into the suction side with high acceleration, disturbing the primary flow and causing more erosion and losses in downstream turbine components. A cascade rig containing a single guide vane passage has been built to study the effect of the clearance gap using pressure sensors and PIV (Particle Image Velocimetry technique. This study focuses on developing a numerical model of the test rig, validating the results with experiments and investigating the behavior of leakage flow numerically. It was observed from both CFD and experiment that the leakage flow forms a passage vortex, which shifts away from the wall while travelling downstream. The streamlines contributing to the formation of this vortex have been discussed. Furthermore, the reference guide vane with symmetrical hydrofoil has been compared with four cambered profiles, in terms of the guide vane loading and the consequent effect on the leakage flow. A dimensionless term called Leakage Flow Factor (Lff has been introduced to compare the performances of hydrofoils. It is shown that the leakage flow and its effect on increasing losses and erosion can be minimized by changing the pressure distribution over the guide vane.

  19. Evaluation of effect of low opening operation on increasing wear of bearing bushings of guide vanes used in hydropower plants

    International Nuclear Information System (INIS)

    Kim, Jong Sung; Kim, Se Na

    2012-01-01

    A guide vane plays a key role in controlling the flow rate of water supplied to the turbine of a hydropower plant. It has been reported that guide vane bearing bushings are subjected to considerable wear, which requires them to be maintained. An ancillary service such as frequency control and black start causes cyclic low opening operation of the guide vanes. It is empirically well known that such operation increases the wear rate of the guide vane bearing bushing. In this study, the effect of low opening operation on the increasing wear of the guide vane bearing bushing is quantitatively assessed via finite element flow analysis, finite element stress analysis, and relative wear evaluation. As a result of the assessment, it is identified that the pressure applied on the guide vane surface increases and the contact length between the outer surface of the guide vane stem and the inner surface of the bearing bushing decreases with a decrease in the opening of the guide vane. In addition, low opening of the guide vanes results in an increase in the relative wear owing to the generation of high contact pressure on the bearing bushing surfaces

  20. Discussion on the re-irradiated fuel assembly with damaged guide vanes

    International Nuclear Information System (INIS)

    Li Ligang

    2013-01-01

    In January 2011, during the second plant of CNNC Nuclear Power Operations Management Co., Ltd.(hereinafter referred to as the second plant) refueling outage, the visual inspection found the guide vanes of fuel assembly A had felling off. After the National Nuclear Safety Administration (NNSA) estimated and approved, the fuel assembly A was reloaded in the specified location of reactor core. During the refueling outage in March 2012, the fuel assembly A was removed again from the reactor core. Visual inspection confirmed that the fuel assembly A was complete and without abnormal changes. The practice provides reference for re-irradiated of fuel assembly with the same type of damaged guide vanes, and provides case support for standard development for the same type of re-irradiated fuel assembly with damaged guide vanes. (author)

  1. Performance and internal flow characteristics of a cross-flow turbine by guide vane angle

    International Nuclear Information System (INIS)

    Chen, Z M; Choi, Y D

    2013-01-01

    This study attempts to investigate the performance and internal flow characteristics of a cross-flow turbine by guide vane angle. In order to improve the performance of a cross flow turbine, the paper presents a numerical investigation of the turbine with air supply and discusses the influence of variable guide vane angle on the internal flow. A newly developed air supply from air suction Hole is adopted. To investigate the performance and internal flow of the cross-flow turbine, the CFD software based on the two-phase flow model is utilized. The numerical grids are made in two-dimensional geometry in order to shorten the time of two-phase calculations. Then a series of CFD analysis has been conducted in the range of different guide vane angle. Moreover, local output power is divided at different stages and the effect of air layer in each stage is examined

  2. Assessment of guide vane self-excitation stability at small openings in pump flow

    International Nuclear Information System (INIS)

    Nennemann, B; Sallaberger, M; Henggeler, U; Gentner, C; Parkinson, E

    2012-01-01

    A parameter study of self-excited pump turbine guide vane instability at small openings using a combined CFD-1DOF approach shows that clear tendencies are difficult to obtain. Two types of boundary conditions can be used in the simulations: prescribed mass flow and prescribed pressure. Simulations with both show results that - for one specific operating condition - are consistent with a self-excited guide vane incident at a prototype pump turbine. However, over a larger range of reduced velocities, the tendencies obtained with the two boundary condition types are not always consistent. Pressure boundary conditions may be the more realistic option. Results then show that with increasing reduced velocity, guide vanes will eventually reach static instability or divergence. This may not be problematic. In contrast, passing through a zone of dynamic instability during operation should and can be avoided.

  3. Study of turbine and guide vanes integration to enhance the performance of cross flow vertical axis wind turbine

    Science.gov (United States)

    Wibowo, Andreas; Tjahjana, Dominicus Danardono Dwi Prija; Santoso, Budi; Situmorang, Marcelinus Risky Clinton

    2018-02-01

    The main purpose of this study is to investigate the best configuration between guide vanes and cross flow vertical axis wind turbine with variation of several parameters including guide vanes tilt angle and the number of turbine and guide vane blades. The experimental test were conducted under various wind speed and directions for testing cross flow wind turbine, consisted of 8, 12 and 16 blades. Two types of guide vane were developed in this study, employing 20° and 60° tilt angle. Both of the two types of guide vane had three variations of blade numbers which had same blade numbers variations as the turbines. The result showed that the configurations between 60° guide vane with 16 blade numbers and turbine with 16 blade numbers had the best configurations. The result also showed that for certain configuration, guide vane was able to increase the power generated by the turbine significantly by 271.39% compared to the baseline configuration without using of guide vane.

  4. Erosion estimation of guide vane end clearance in hydraulic turbines with sediment water flow

    Science.gov (United States)

    Han, Wei; Kang, Jingbo; Wang, Jie; Peng, Guoyi; Li, Lianyuan; Su, Min

    2018-04-01

    The end surface of guide vane or head cover is one of the most serious parts of sediment erosion for high-head hydraulic turbines. In order to investigate the relationship between erosion depth of wall surface and the characteristic parameter of erosion, an estimative method including a simplified flow model and a modificatory erosion calculative function is proposed in this paper. The flow between the end surfaces of guide vane and head cover is simplified as a clearance flow around a circular cylinder with a backward facing step. Erosion characteristic parameter of csws3 is calculated with the mixture model for multiphase flow and the renormalization group (RNG) k-𝜀 turbulence model under the actual working conditions, based on which, erosion depths of guide vane and head cover end surfaces are estimated with a modification of erosion coefficient K. The estimation results agree well with the actual situation. It is shown that the estimative method is reasonable for erosion prediction of guide vane and can provide a significant reference to determine the optimal maintenance cycle for hydraulic turbine in the future.

  5. Methodology of Computer-Aided Design of Variable Guide Vanes of Aircraft Engines

    Science.gov (United States)

    Falaleev, Sergei V.; Melentjev, Vladimir S.; Gvozdev, Alexander S.

    2016-01-01

    The paper presents a methodology which helps to avoid a great amount of costly experimental research. This methodology includes thermo-gas dynamic design of an engine and its mounts, the profiling of compressor flow path and cascade design of guide vanes. Employing a method elaborated by Howell, we provide a theoretical solution to the task of…

  6. Analysis of waves in the plasma guided by a periodical vane-type slow wave structure

    International Nuclear Information System (INIS)

    Wu, T.J.; Kou, C.S.

    2005-01-01

    In this study, the dispersion relation has been derived to characterize the propagation of the waves in the plasma guided by a periodical vane-type slow wave structure. The plasma is confined by a quartz plate. Results indicate that there are two different waves in this structure. One is the plasma mode that originates from the plasma surface wave propagating along the interface between the plasma and the quartz plate, and the other is the guide mode that originally travels along the vane-type slow wave structure. In contrast to its original slow wave characteristics, the guide mode becomes a fast wave in the low-frequency portion of the passband, and there exists a cut-off frequency for the guide mode. The vane-type guiding structure has been shown to limit the upper frequency of the passband of the plasma mode, compared with that of the plasma surface wave. In addition, the passband of the plasma mode increases with the plasma density while it becomes narrower for the guide mode. The influences of the parameters of the guiding structure and plasma density on the propagation of waves are also presented

  7. Improvement of wells turbine performance by means of 3D guide vanes; Sanjigen annai hane ni yoru wells turbine seino no kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Takao, M.; Kim, T.H. [Saga University, Saga (Japan); Setoguchi, T. [Saga University, Saga (Japan). Faculty of Science and Engineering; Inoue, M. [Kyushu University, Fukuoka (Japan). Faculty of Engineering

    2000-02-25

    Performance of a Wells turbine was improved by equipping 3D guide vanes before and behind a rotor. For further improvement, 3D guide vanes have been proposed in this paper. The performance of the Wells turbine with 2D and 3D guide vanes have been investigated experimentally by model testing under steady flow conditions. Then, the running and starting characteristics in irregular ocean waves have been obtained by a computer simulation. As a result, it is found that both of the running and starting characteristics of the Wells turbine with 3D guide vanes are superior to those of the turbine with 2D guide vanes. (author)

  8. Analysis on influence of guide vanes closure laws of pump-turbine on load rejection transient process

    Science.gov (United States)

    Yao, Z.; Bi, H. L.; Huang, Q. S.; Li, Z. J.; Wang, Z. W.

    2013-12-01

    In load rejection transient process, the sudden shut down of guide vanes may cause units speed rise and a sharp increase in water hammer pressure of diversion system, which endangers the safety operation of the power plant. Adopting reasonable guide vane closure law is a kind of economic and effective measurement to reduce the water hammer pressure and limit rotational speed increases. In this paper, combined with Guangzhou Pumped Storage Power Station plant A, the load rejection condition under different guide vanes closure laws is calculated and the key factor of guide vanes closure laws on the impact of the load rejection transition process is analyzed. The different inflection points, which are the closure modes, on the impact of unit speed change, water level fluctuation of surge tank, and the pressure fluctuation of volute inlet and draft tube inlet are further discussed. By compared with the calculation results, a reasonable guide vanes inflection point position can be determined according to security requirements and a reasonable guide vanes closure law can be attained to effectively coordinate the unit speed rise and the rapid pressure change in the load rejection transient process.

  9. Flow control in axial fan inlet guide vanes by synthetic jets

    Directory of Open Access Journals (Sweden)

    Wurst P.

    2013-04-01

    Full Text Available Tested high pressure axial flow fan with hub/tip ratio of 0.70 and external diameter of 600 mm consisted of inlet guide vanes (IGV, rotor and stator blade rows. Fan peripheral velocity was 47 m/s. Air volume flow rate was changed by turning of rear part of the inlet guide vanes. At turning of 20 deg the flow was separated on the IGV profiles. The synthetic jets were introduced through radial holes in machine casing in the location before flow separation origin. Synthetic jet actuator was designed with the use of a speaker by UT AVCR. Its membrane had diameter of 63 mm. Excitation frequency was chosen in the range of 500 Hz – 700 Hz. Synthetic jets favourably influenced separated flow on the vane profiles in the distance of (5 – 12 mm from the casing surface. The reduction of flow separation area caused in the region near the casing the decrease of the profile loss coefficient approximately by 20%.

  10. Flow control in axial fan inlet guide vanes by synthetic jets

    Science.gov (United States)

    Cyrus, V.; Trávníček, Z.; Wurst, P.; Kordík, J.

    2013-04-01

    Tested high pressure axial flow fan with hub/tip ratio of 0.70 and external diameter of 600 mm consisted of inlet guide vanes (IGV), rotor and stator blade rows. Fan peripheral velocity was 47 m/s. Air volume flow rate was changed by turning of rear part of the inlet guide vanes. At turning of 20 deg the flow was separated on the IGV profiles. The synthetic jets were introduced through radial holes in machine casing in the location before flow separation origin. Synthetic jet actuator was designed with the use of a speaker by UT AVCR. Its membrane had diameter of 63 mm. Excitation frequency was chosen in the range of 500 Hz - 700 Hz. Synthetic jets favourably influenced separated flow on the vane profiles in the distance of (5 - 12) mm from the casing surface. The reduction of flow separation area caused in the region near the casing the decrease of the profile loss coefficient approximately by 20%.

  11. Mounting apparatus for a nozzle guide vane assembly

    Science.gov (United States)

    Boyd, Gary L.; Shaffer, James E.

    1995-01-01

    The present invention provides a ceramic nozzle guide assembly with an apparatus for mounting it to a metal nozzle case that includes an intermediate ceramic mounting ring. The mounting ring includes a plurality of projections that are received within a plurality of receptacles formed in the nozzle case. The projections of the mounting ring are secured within the receptacles by a ceramic retainer that allows contact between the two components only along arcuate surfaces thus eliminating sliding contact between the components.

  12. Flow characteristics of guide vane of diffuser pump by PIV measurement

    International Nuclear Information System (INIS)

    Kim, J. H.; Lee, Young Ho; Choi, J. W.; Kim, M. Y.; Lee, H.

    2000-01-01

    The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within a diffuser pump. Various different kinds of clearance were selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors was implemented with direct calculation of correlation coefficients. Fine optical setup important in PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Various flow patterns are represented quantitatively at the stator passages

  13. Experimental investigation of in-cylinder air flow to optimize number of helical guide vanes to enhance DI diesel engine performance using mamey sapote biodiesel

    Science.gov (United States)

    Kumar, A. Raj; Janardhana Raju, G.; Hemachandra Reddy, K.

    2018-03-01

    The current research work investigates the influence of helical guide vanes in to the intake runner of a D.I diesel engine operating by the high viscous Mamey Sapote biodiesel to enhance in-cylinder suction air flow features. Helical guide vanes of different number of vanes are produced from 3D printing and placed in the intake manifold to examine the air flow characteristics. Four different helical guide vane devices namely 3, 4, 5 and 6 vanes of the same dimensions are tested in a D.I diesel engine operating with Mamey Sapote biodiesel blend. As per the experimental results of engine performance and emission characteristics, it is found that 5 vanes helical guide vane swirl device exhibited in addition number of increased improvements such as the brake power and bake thermal efficiency by 2.4% and 8.63% respectively and the HC, NOx, Carbon monoxide and, Smoke densities are reduced by 15.62%, 4.23%, 14.27% and 9.6% at peak load operating conditions as collate with normal engine at the same load. Hence this investigation concluded that Helical Guide Vane Devices successfully enhanced the in-cylinder air flow to improve better addition of Mamey Sapote biodiesel with air leading in better performance of the engine than without vanes.

  14. Performance Enhancement of the In-Line Fan Equipped with the Guiding Vane and the Tail Body

    Directory of Open Access Journals (Sweden)

    Hung-Cheng Yen

    2014-02-01

    Full Text Available This integrated numerical and experimental study intends to enhance the performance of an in-line fan with the implement of the guiding vane and the tail body. At first the flow flied associated with the original in-line fan is simulated and analyzed within the framework of CFD code Fluent, in which the finite volume method is applied. Next, the guiding vane is constructed based on the calculated flow characteristics, and attached in the downstream of rotor to smoothen the flow pattern. An appropriate guiding vane with high-performance and low-noise features can be achieved after several design iterations. In addition, the tail body connected to the motor is introduced for further enhancing the fan performance by reducing the sizes of wake and reversed flow behind the hub. Thereafter, to manufacture the mockup for experimental verification, the modified fan with guiding vane is plotted in the CAD/CAM format for mockup fabrication via the rapid-prototype technique. Moreover, a set of relations correlating the performance and noise of this fan prototype are executed inside AMCA test chamber and semianechoic chamber, respectively. Consequently, the feasibility of design scheme and numerical system can be verified according to these experimental results. In summary, this work provides a systematic scheme for designing and analyzing the in-line fan.

  15. Numerical study of pressure fluctuations in different guide vanes' opening angle in pump mode of a pump turbine

    International Nuclear Information System (INIS)

    Sun, Y K; Zuo, Z G; Liu, S H; Wu, Y L; Liu, J T

    2012-01-01

    A numerical model based on a pumped storage power station was built to develop the numerical simulation, to analyze the pressure fluctuations in a pump turbine in different guide vanes' opening angle. The different guide vanes' opening angles were simulated using the SST k-ω turbulence model and SIMPLEC Pressure-Velocity coupling scheme. The pressure sensor were placed in mainly three positions, they are: bottom ring between runner and the wicket gates, downstream and left side in the draft tube cone below the runner. All the peak to peak values of pressure fluctuation meet signal probability of 97%. The frequency is gained by Fast Fourier Transform. The pressure fluctuations in different positions of the model in pump condition were showed when the guide vanes' opening angels were different. The simulation results confirmed the results gained in model tests. The results show that pressure fluctuations in design opening angle were much lower than those in off design opening angle. The main source of pressure fluctuations between runner and guide vanes is rotor stator interaction. While a lower frequency is the main frequency of the pressure fluctuation in draft tube.

  16. Application of dynamic slip wall modeling to a turbine nozzle guide vane

    Science.gov (United States)

    Bose, Sanjeeb; Talnikar, Chaitanya; Blonigan, Patrick; Wang, Qiqi

    2015-11-01

    Resolution of near-wall turbulent structures is computational prohibitive necessitating the need for wall-modeled large-eddy simulation approaches. Standard wall models are often based on assumptions of equilibrium boundary layers, which do not necessarily account for the dissimilarity of the momentum and thermal boundary layers. We investigate the use of the dynamic slip wall boundary condition (Bose and Moin, 2014) for the prediction of surface heat transfer on a turbine nozzle guide vane (Arts and de Rouvroit, 1992). The heat transfer coefficient is well predicted by the slip wall model, including capturing the transition to turbulence. The sensitivity of the heat transfer coefficient to the incident turbulence intensity will additionally be discussed. Lastly, the behavior of the thermal and momentum slip lengths will be contrasted between regions where the strong Reynolds analogy is invalid (near transition on the suction side) and an isothermal, zero pressure gradient flat plate boundary layer (Wu and Moin, 2010).

  17. Tubular-Type Hydroturbine Performance for Variable Guide Vane Opening by CFD

    Science.gov (United States)

    Kim, Y. T.; Nam, S. H.; Cho, Y. J.; Hwang, Y. C.; Choi, Y. D.; Nam, C. D.; Lee, Y. H.

    Micro hydraulic power generation which has output of less or equal to 100kW is attracting considerable attention. This is because of its small, simple, renewable, and large amount of energy resources. By using a small hydro power generator of which main concept is based on using differential water pressures in pipe lines, energy which was initially wasted by use of a reducing valve at an end of the pipeline, is collected by a turbine in the hydro power generator. A propeller shaped hydroturbine has been used in order to make use of this renewable pressure energy. In this study, in order to acquire basic design data of tubular type hydroturbine, output power, head, and efficiency characteristics due to the guide vane opening angle are examined in detail. Moreover, influences of pressure, tangential and axial velocity distributions on turbine performance are investigated by using a commercial CFD code.

  18. Capacity control of rotary vane apparatus

    International Nuclear Information System (INIS)

    Roberts, R. W.

    1985-01-01

    A capacity control arrangement for a rotary vane fluid displacement apparatus, such as a rotary vane compressor, having a vane retaining means that normally engages and retains the vanes in their retracted or nonworking position within the rotor defined guide slits of such rotary vane compressor. The retaining means are actuated to the vane-disengaged position by hydraulic control fluid which is communicated to the retaining means in response to an external parameter sensed by a control means

  19. Numerical investigation of variable inlet guide vanes with trailing-edge dual slots to decrease the aerodynamic load on centrifugal compressor impeller

    Directory of Open Access Journals (Sweden)

    Jianchi Xin

    2016-03-01

    Full Text Available In engineering practice, most centrifugal compressors use variable inlet guide vanes which can provide pre-whirl and control volume flow rates. As the impeller of a centrifugal compressor passes through the wakes created from the guide vanes, the aerodynamic parameters change significantly. The concept of adding dual slots at the trailing-edge of the guide vanes is proposed for reducing the aerodynamic load on the compressor impeller blades. In this article, the steady and unsteady performances of the new guide vanes are analysed under two compressor operating conditions (winter and design conditions. The results show that the average amplitude of the impeller passing frequency at the leading edge has a 13% decrease under the winter condition, especially at the middle and root parts. Moreover, the dual slots structure has no effect on the overall compressor performance.

  20. Advanced Instrumentation for Measuring Fluid-Structure Coupling Phenomena in the Guide Vanes Cascade of a Pump-Turbine Scale Model

    OpenAIRE

    Roth, Steven; Hasmatuchi, Vlad; Botero, Francisco; Farhat, Mohamed; Avellan, François

    2010-01-01

    In the present study, the fluid-structure coupling is investigated in the guide vanes of a pump-turbine scale model placed in one of the test rigs of the Laboratory for Hydraulic Machines (EPFL) in Lausanne. The paper focuses on the advanced instrumentation used to get reliable and complete fluid-structure coupling results. Semi-conductor strain gages are installed on three guide vanes which are especially weakened to account for stronger fluid-structure coupling phenomena. These are statical...

  1. The NTF Inlet Guide Vanes Thermal Gradient Problem and Its Mitigation

    Science.gov (United States)

    Venkat, Venki S.; Paryz, Roman W.; Bissett, Owen W.; Kilgore, W.

    2013-01-01

    The National Transonic Facility (NTF) utilizes Inlet Guide Vanes (IGV) to provide precise, quick response Mach number control for the tunnel. During cryogenic operations, the massive IGV structure can experience large thermal gradients, measured as "Delta T or (Delta)T", between the IGV ring and its support structure called the transfer case. If these temperature gradients are too large, the IGV structure can be stressed beyond its safety limit and cease operation. In recent years, (Delta)T readings exceeding the prescribed safety limits were observed frequently during cryogenic operations, particularly during model access. The tactical operation methods of the tunnel to minimize (Delta)T did not always succeed. One obvious option to remedy this condition is to warm up the IGV structure by disabling the main drive operation, but this "natural" warm up method can takes days in some cases, resulting in productivity loss. This paper documents the thermal gradient problem associated with the IGV structure during cryogenic operation and how the facility has recently achieved an acceptable mitigation which has resulted in improved efficiency of operations.

  2. Combining effect of optimized axial compressor variable guide vanes and bleed air on the thermodynamic performance of aircraft engine system

    International Nuclear Information System (INIS)

    Kim, Sangjo; Son, Changmin; Kim, Kuisoon

    2017-01-01

    Aim of this work is to provide evidence of the effectiveness of combined use of the variable guide vanes (VGVs) and bleed air on the thermodynamic performance of aircraft engine system. This paper performed the comparative study to evaluate the overall thermal performance of an aircraft engine with optimized VGVs and bleed air, separately or simultaneously. The low-bypass ratio turbofan engine has been modeled with a 0D/1D modeling approach. The genetic algorithm is employed to find the optimum schedule of VGVs and bleed air. There are four types of design variables: (1) the inlet guide vane (IGV) angle, (2) the IGV and 1st stator vane (SV) angles, (3) bleed air mass flow rate at the exit of the axial compressor, and (4) both type 2 and type 3. The optimization is conducted with surge margin constraints of more than 10% and 15% in the axial compressor. The results show that the additional use of the bleed air increases the efficiency of the compressors. Overall, the percentage reductions of the total fuel consumption for the engine with the IGV, 1st SV and bleed air schedule is 1.63% for 15% surge margin constraints when compared with the engine with the IGV schedule. - Highlights: • The effect of combined use of variable guide vanes and bleed air is evaluated. • The genetic algorithm is employed to find the optimum setting angle and bleed air. • A low bypass ratio mixed turbofan engine is analyzed for optimization. • Additional use of the bleed air shows improved overall performance of the engine.

  3. Rotor boundary layer development with inlet guide vane (IGV) wake impingement

    Science.gov (United States)

    Jia, Lichao; Zou, Tengda; Zhu, Yiding; Lee, Cunbiao

    2018-04-01

    This paper examines the transition process in a boundary layer on a rotor blade under the impingement of an inlet guide vane wake. The effects of wake strengths and the reduced frequency on the unsteady boundary layer development on a low-speed axial compressor were investigated using particle image velocimetry. The measurements were carried out at two reduced frequencies (fr = fIGVS0/U2i, fr = 1.35, and fr = 0.675) with the Reynolds number, based on the blade chord and the isentropic inlet velocity, being 97 500. At fr = 1.35, the flow separated at the trailing edge when the wake strength was weak. However, the separation was almost totally suppressed as the wake strength increased. For the stronger wake, both the wake's high turbulence and the negative jet behavior of the wake dominated the interaction between the unsteady wake and the separated boundary layer on the suction surface of the airfoil. The boundary layer displacement thickened first due to the negative jet effect. Then, as the disturbances developed underneath the wake, the boundary layer thickness reduced gradually. The high disturbance region convected downstream at a fraction of the free-stream velocity and spread in the streamwise direction. The separation on the suction surface was suppressed until the next wake's arrival. Because of the long recovery time at fr = 0.675, the boundary layer thickened gradually as the wake convected further downstream and finally separated due to the adverse pressure gradient. The different boundary layer states in turn affected the development of disturbances.

  4. Novel investigation of the different Omni-direction-guide-vane angles effects on the urban vertical axis wind turbine output power via three-dimensional numerical simulation

    International Nuclear Information System (INIS)

    Shahizare, B.; Nik-Ghazali, N.; Chong, W.T.; Tabatabaeikia, S.; Izadyar, Nima; Esmaeilzadeh, Alireza

    2016-01-01

    Highlights: • Investigation of the Omni-direction-guide-vane impacts on the VAWT performance. • Obtain the best position of the guide vane angles in order to achieve the maximum performance. • Validation of the 3D computational fluid dynamics with experimental data. • Acquire the optimal Omni-direction-guide-vane based on numerical simulation results. - Abstract: The aim of this study is to present the effects of different Omni-direction-guide-vane (ODGV) angles on the performance of the vertical axis wind turbine (VAWT). For this purpose, five different straight-bladed VAWTs have been simulated via three-dimensional (3D) computational fluid dynamics (CFD). Hence, the VAWT without ODGV covering, were simulated and validated via CFD and experimental fluid dynamics (EFD) data, respectively in the first step. Indeed, grid and time step independency test as well as the effect of domain size, have been conducted and a suitable agreement was found based on comparison of the CFD and EFD results. In the next step, the VAWT was shrouded by ODGV cover and the whole system was simulated for 52 angles of the ODGV in four different tip speed ratios (TSR), to investigate the impact of guide vanes angles on the VAWT performance. Results of this study indicated that output power of the VAWT with α = 20° and β = 55° ODGV guide vanes, was improved 40.9%, 36.5%, 35.3% and 33.2%, respectively in four different TSR including 0.745, 1.091, 1.901 and 2.53.

  5. Influence of omni-directional guide vane on the performance of cross-flow rotor for urban wind energy

    Science.gov (United States)

    Wicaksono, Yoga Arob; Tjahjana, Dominicus Danardono Dwi Prija; Hadi, Syamsul

    2018-02-01

    Vertical axis wind turbine like cross-flow rotor have some advantage there are, high self-starting torque, low noise, and high stability; so, it can be installed in the urban area to produce electricity. But, the urban area has poor wind condition, so the cross-flow rotor needs a guide vane to increase its performance. The aim of this study is to determine experimentally the effect of Omni-Directional Guide Vane (ODGV) on the performance of a cross-flow wind turbine. Wind tunnel experiment has been carried out for various configurations. The ODGV was placed around the cross-flow rotor in order to increase ambient wind environment of the wind turbine. The maximum power coefficient is obtained as Cpmax = 0.125 at 60° wind direction. It was 21.46% higher compared to cross-flow wind turbine without ODGV. This result showed that the ODGV able to increase the performance of the cross-flow wind turbine.

  6. Studi Eksperimen Aliran Melalui Square Duct dan Square Elbow 90º dengan Double Guide Vane pada Variasi Sudut Bukaan Damper

    Directory of Open Access Journals (Sweden)

    Andrew Jaya Nazar

    2017-01-01

    Full Text Available Instalasi saluran udara tidak hanya berupa pipa lurus, tetapi juga terdapat fitting/aksesoris perpipaan misalnya elbow 90o dan damper. Aksesoris perpipaan ini berfungsi agar saluran udara dapat terpasang sesuai dengan kebutuhan. Namun, penggunaan aksesoris perpipaan ini menyebabkan bertambahnya pressure drop akibat adanya friction loss dan separation loss. Pemasangan guide vane pada elbow 90o diharapkan dapat mengurangi pressure drop karena dapat mengurangi terjadinya secondary flow, namun hal ini dapat menambah kerugian akibat gaya gesek. Saat ini penghematan energi menjadi sorotan terutama dalam dunia industri. Penurunan pressure drop pada belokan perpipaan sangat diharapkan, agar dapat menghemat energi lebih. Untuk itu perlu dilakukan usaha agar dapat menurunkan pressure drop yang terjadi. Penelitian ini dilakukan secara eksperimen dengan benda uji saluran udara yang terdiri dari: upstream duct (straight duct, square elbow 90o dengan r/Dh=1,5 dan dilengkapi double guide vane, damper, downstream duct (straight duct, dan induced fan. Pengukuran parameter yang dibutuhkan dilakukan dengan menggunakan: pitot tube, inclined manometer, pressure tranducer. Dari eksperimen ini diperoleh bahwa profil kecepatan pada masing-masing variasi sudut bukaan damper sudah mendekati keadaan recovery aliran pada akhir section baik dari bidang vertikal maupun horizontal. Pressure drop yang terjadi semakin naik seiring dengan bertambahnya nilai bilangan Reynolds dan sudut bukaan damper. Nilai konstanta damper semakin naik dari bukaan sudut 0o hingga 30o.

  7. 3D computations of flow field in a guide vane blading designed by means of 2D model for a low head hydraulic turbine

    International Nuclear Information System (INIS)

    Krzemianowski, Z; Puzyrewski, R

    2014-01-01

    The paper presents the main parameters of the flow field behind the guide vane cascade designed by means of 2D inverse problem and following check by means of 3D commercial program ANSYS/Fluent applied for a direct problem. This approach of using different models reflects the contemporary design procedure for non-standardized turbomachinery stage. Depending on the model, the set of conservation equation to be solved differs, although the physical background remains the same. The example of computations for guide vane cascade for a low head hydraulic turbine is presented.

  8. Numerical Study of the Effects of Thermal Barrier Coating and Turbulence Intensity on Cooling Performances of a Nozzle Guide Vane

    Directory of Open Access Journals (Sweden)

    Prasert Prapamonthon

    2017-03-01

    Full Text Available This work presents a numerical investigation of the combined effects of thermal barrier coating (TBC with mainstream turbulence intensity (Tu on a modified vane of the real film-cooled nozzle guide vane (NGV reported by Timko (NASA CR-168289. Using a 3D conjugate heat transfer (CHT analysis, the NGVs with and without TBC are simulated at three Tus (Tu = 3.3%, 10% and 20%. The overall cooling effectiveness, TBC effectiveness and heat transfer coefficient are analyzed and discussed. The results indicate the following three interesting phenomena: (1 TBC on the pressure side (PS is more effective than that on the suction side (SS due to a fewer number of film holes on the SS; (2 for all three Tus, the variation trends of the overall cooling effectiveness are similar, and TBC plays the positive and negative roles in heat flux at the same time, and significantly increases the overall cooling effectiveness in regions cooled ineffectively by cooling air; (3 when Tu increases, the TBC effect is more significant, for example, at the highest Tu (Tu = 20% the overall cooling effectiveness can increase as much as 24% in the film cooling ineffective regions, but near the trailing edge (TE and the exits and downstream of film holes on the SS, this phenomenon is slight.

  9. Numerical investigation on pressure fluctuations in centrifugal compressor with different inlet guide vanes pre-whirl angles

    Science.gov (United States)

    Wang, Y. C.; Shi, M.; Cao, S. L.; Li, Z. H.

    2013-12-01

    The pressure fluctuations in a centrifugal compressor with different inlet guide vanes (IGV) pre-whirl angles were investigated numerically, as well as the pre-stress model and static structural of blade. The natural frequency was evaluated by pre-stress model analysis. The results show that, the aero-dynamic pressure acting on blade surface is smaller than rotation pre-stress, which wouldn't result in large deformation of blade. The natural frequencies with rotation pre-stress are slightly higher than without rotation pre-stress. The leading mechanism of pressure fluctuations for normal conditions is the rotor-stator (IGVs) interaction, while is serious flow separations for conditions that are close to surge line. A few frequency components in spectra are close to natural frequency, which possibly result in resonant vibration if amplitude is large enough, which is dangerous for compressor working, and should be avoided.

  10. Numerical investigation on pressure fluctuations in centrifugal compressor with different inlet guide vanes pre-whirl angles

    International Nuclear Information System (INIS)

    Wang, Y C; Shi, M; Cao, S L; Li, Z H

    2013-01-01

    The pressure fluctuations in a centrifugal compressor with different inlet guide vanes (IGV) pre-whirl angles were investigated numerically, as well as the pre-stress model and static structural of blade. The natural frequency was evaluated by pre-stress model analysis. The results show that, the aero-dynamic pressure acting on blade surface is smaller than rotation pre-stress, which wouldn't result in large deformation of blade. The natural frequencies with rotation pre-stress are slightly higher than without rotation pre-stress. The leading mechanism of pressure fluctuations for normal conditions is the rotor-stator (IGVs) interaction, while is serious flow separations for conditions that are close to surge line. A few frequency components in spectra are close to natural frequency, which possibly result in resonant vibration if amplitude is large enough, which is dangerous for compressor working, and should be avoided

  11. The design, simulation and testing of an urban vertical axis wind turbine with the omni-direction-guide-vane

    International Nuclear Information System (INIS)

    Chong, W.T.; Fazlizan, A.; Poh, S.C.; Pan, K.C.; Hew, W.P.; Hsiao, F.B.

    2013-01-01

    Graphical abstract: Solar energy, renewable energy, urban wind energy, environment, augmented wind turbine. Highlights: ► A system for on-site wind–solar hybrid power generation and rain water collection. ► The omni-direction-guide-vane (ODGV) overcomes the weak wind and turbulence conditions in urban areas. ► The ODGV improves the wind turbine performance by speeding-up and guiding the wind. ► The ODGV is designed to blend into the building architecture with safety enhancement. ► The wind tunnel test and CFD simulation results are presented. - Abstract: A novel omni-direction-guide-vane (ODGV) that surrounds a vertical axis wind turbine (VAWT) is designed to improve the wind turbine performance. Wind tunnel testing was performed to evaluate the performance of a 5-bladed (Wortmann FX63-137 airfoil) H-rotor wind turbine, with and without the integration of the ODGV. The test was conducted using a scaled model turbine which was constructed to simulate the VAWT enclosed by the ODGV placed on a building. The VAWT shows an improvement on its self-starting behavior where the cut-in speed was reduced with the integration of the ODGV. Since the VAWT is able to self-start at a lower wind speed, the working hour of the wind turbine would increase. At a wind speed of 6 m/s and under free-running condition (only rotor inertia and bearing friction were applied), the ODGV helps to increase the rotor rotational speed by 182%. With extra load application at the same wind speed (6 m/s), the wind turbine power output was increased by 3.48 times at its peak torque with the aid of the ODGV. The working concept of the ODGV is to minimize the negative torque zone of a lift-type VAWT and to reduce turbulence and rotational speed fluctuation. It was verified by re-simulating the torque coefficient data of a single bladed (NACA 0015 airfoil) VAWT published by the Sandia National Laboratories. From the simulation results, with the presence of the ODGV, it was shown that the

  12. Improvement of the efficiency of the Agnew micro hydro turbine at part loads due to installing guide vanes mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Yassi, Yousef; hashemloo, Safar [Iranian Research Organization for Science and Technology (IROST), No. 29 Forssat St., Enghelaab Ave., Tehran (Iran)

    2010-10-15

    Agnew turbine is an axial micro hydro of Kaplan type, with its main shaft subtending 45 to the line of horizon. Due to governmental power generating programs for limited hydro potentials in Iran and on the basis of a joint project between the University of Glasgow and the Iranian Research Organization for Science and Technology (IROST), the turbine was developed to operate under low heads and limited flow potentials in Iran. However the turbine was originally designed to operate without any guide vanes and test results showed that the turbine achieved an efficiency of 62% at its best point of performance. Later a modified Agnew turbine, consisting of a guide blades mechanism was designed and manufactured, at (IROST). The mechanism was so designed that it was also used as a second support for the turbine's main shaft. The standard turbine tests proved that; the modified version of the Agnew turbine had 23% higher efficiency at its best performance point; compared to the original design. Then the effects of the improvements on the turbine were studied on the performance of the turbine at part loads. However, efficiency improvements were observed under all part load conditions. (author)

  13. Improvement of the efficiency of the Agnew micro hydro turbine at part loads due to installing guide vanes mechanism

    International Nuclear Information System (INIS)

    Yassi, Yousef; Hashemloo, Safar

    2010-01-01

    Agnew turbine is an axial micro hydro of Kaplan type, with its main shaft subtending 45 deg. to the line of horizon. Due to governmental power generating programs for limited hydro potentials in Iran and on the basis of a joint project between the University of Glasgow and the Iranian Research Organization for Science and Technology (IROST), the turbine was developed to operate under low heads and limited flow potentials in Iran. However the turbine was originally designed to operate without any guide vanes and test results showed that the turbine achieved an efficiency of 62% at its best point of performance. Later a modified Agnew turbine, consisting of a guide blades mechanism was designed and manufactured, at (IROST). The mechanism was so designed that it was also used as a second support for the turbine's main shaft. The standard turbine tests proved that; the modified version of the Agnew turbine had 23% higher efficiency at its best performance point; compared to the original design. Then the effects of the improvements on the turbine were studied on the performance of the turbine at part loads. However, efficiency improvements were observed under all part load conditions.

  14. Sliding vane geometry turbines

    Science.gov (United States)

    Sun, Harold Huimin; Zhang, Jizhong; Hu, Liangjun; Hanna, Dave R

    2014-12-30

    Various systems and methods are described for a variable geometry turbine. In one example, a turbine nozzle comprises a central axis and a nozzle vane. The nozzle vane includes a stationary vane and a sliding vane. The sliding vane is positioned to slide in a direction substantially tangent to an inner circumference of the turbine nozzle and in contact with the stationary vane.

  15. Investigation of the Optimal Omni-Direction-Guide-Vane Design for Vertical Axis Wind Turbines Based on Unsteady Flow CFD Simulation

    Directory of Open Access Journals (Sweden)

    Behzad Shahizare

    2016-03-01

    Full Text Available With soaring energy demands, the desire to explore alternate and renewable energy resources has become the focal point of various active research fronts. Therefore, the scientific community is revisiting the notion to tap wind resources in more rigorous and novel ways. In this study, a two-dimensional computational investigation of the vertical axis wind turbine (VAWT with omni-direction-guide-vane (ODGV is proposed to determine the effects of this guide vane. In addition, the mesh and time step (dt size dependency test, as well as the effect of the different turbulence models on results accuracy are investigated. Eight different shape ratios (R of the omni-direction-guide-vane were also examined in this study. Further, the CFD model is validated by comparing the numerical results with the experimental data. Validation results show a good agreement in terms of shape and trend in CFD simulation. Based on these results, all the shape ratios, except two ratios including 0.3 and 0.4 at TSR of 1.3 to 3, have a positive effect on the power and torque coefficient improvement. Moreover, results show that the best case has a shape ratio of 0.55, which improves the power coefficient by 48% and the torque coefficient up to 58%.

  16. Computational study: The influence of omni-directional guide vane on the flow pattern characteristic around Savonius wind turbine

    Science.gov (United States)

    Wicaksono, Yoga Arob; Tjahjana, D. D. D. P.

    2017-01-01

    Standart Savonius wind turbine have a low performance such as low coefficient of power and low coefficient of torque compared with another type of wind turbine. This phenomenon occurs because the wind stream can cause the negative pressure at the returning rotor. To solve this problem, standard Savonius combined with Omni Directional Guide Vane (ODGV) proposed. The aim of this research is to study the influence of ODGV on the flow pattern characteristic around of Savonius wind turbine. The numerical model is based on the Navier-Stokes equations with the standard k-ɛ turbulent model. This equation solved by a finite volume discretization method. This case was analyzed by commercial computational fluid dynamics solver such as SolidWorks Flow Simulations. Simulations were performed at the different wind directions; there are 0°, 30°,60° at 4 m/s wind speed. The numerical method validated with the past experimental data. The result indicated that the ODGV able to augment air flow to advancing rotor and decrease the negative pressure in the upstream of returning rotor compared to the bare Savonius wind turbine.

  17. Numerical study on dissimilar guide vane design with SCC piston for air and emulsified biofuel mixing improvement

    Directory of Open Access Journals (Sweden)

    Hamid Mohd Fadzli

    2017-01-01

    Full Text Available Crude palm oil (CPO is one of the most potential biofuels that can be applied in the conventional diesel engines, where the chemical properties of CPO are comparable to diesel fuel. However, its higher viscosity and heavier molecules can contributes to several engine problems such as low atomization during injection, carbon deposit formation, injector clogging, low mixing with air and lower combustion efficiency. An emulsification of biofuel and modifications of few engine critical components have been identified to mitigate the issues. This paper presents the effects of dissimilar guide vane design (GVD in terms of height variation of 0.25R, 0.3R and 0.35R at the intake manifold with shallow depth re-entrance combustion chamber (SCC piston application to the incylinder air flow characteristics improvement. The simulation results show that the intake manifold with GVD improved the performance of the air flow characteristic particularly swirl, tumble and cross tumble ratios from the intake manifold to the engine. The GVD with the height of 0.3R was found to be the optimum design with respect to the overall improvement of the air flow characteristic. The improvement of the air flow characteristic with the application of GVD and SCC piston in the engine was expected to contribute to a better air fuel mixing, fuel atomization and combustion efficiency of the engine using emulsified biofuel as a source of fuel.

  18. Cavitation on a scaled-down model of a Francis turbine guide vane: high-speed imaging and PIV measurements

    Science.gov (United States)

    Pervunin, K. S.; Timoshevskiy, M. V.; Churkin, S. A.; Kravtsova, A. Yu; Markovich, D. M.; Hanjalić, K.

    2015-12-01

    Cavitation on two symmetric foils, a NACA0015 hydrofoil and a scaled-down model of a Francis turbine guide vane (GV), was investigated by high-speed visualization and PIV. At small attack angles the differences between the profiles of the mean and fluctuating velocities for both hydrofoils were shown to be insignificant. However, at the higher angle of incidence, flow separation from the GV surface was discovered for quasi-steady regimes including cavitation-free and cavitation inception cases. The flow separation leads to the appearance of a second maximum in velocity fluctuations distributions downstream far from the GV surface. When the transition to unsteady regimes occurred, the velocity distributions became quite similar for both foils. Additionally, for the GV an unsteady regime characterized by asymmetric spanwise variations of the sheet cavity length along with alternating periodic detachments of clouds between the sidewalls of the test channel was for the first time visualized. This asymmetric behaviour is very likely to be governed by the cross instability that was recently described by Decaix and Goncalvès [8]. Moreover, it was concluded that the existence of the cross instability is independent on the test body shape and its aspect ratio.

  19. The experimental study on the wind turbine’s guide-vanes and diffuser of an exhaust air energy recovery system integrated with the cooling tower

    International Nuclear Information System (INIS)

    Chong, W.T.; Hew, W.P.; Yip, S.Y.; Fazlizan, A.; Poh, S.C.; Tan, C.J.; Ong, H.C.

    2014-01-01

    Highlights: • On-site exhaust air energy recovery turbine generator mounted above cooling tower. • Energy from wasted wind resources is re-used for electricity generation. • Optimum angle arrangement of guide-vanes and diffusers help to improve wind-flow. • Enclosure solves conventional wind turbine problems. • 13.3% reduction in CO 2 emission is expected to be achieved from this system. - Abstract: An assembly of two vertical axis wind turbines (VAWTs) and an enclosure is installed above a cooling tower to harness the discharged wind for electricity generation. The enclosure consists of guide-vanes and diffuser-plates, is used to enhance the rotational speed of the turbines for power augmentation. The angle of the guide-vanes is optimized to ensure the oncoming wind stream impinges the rotor blades of the turbine at an optimum angle. The diffuser-plates are tilted at an optimum angle to increase the discharged airflow rate. The performance of the system is tested in the laboratory followed by a field test on an actual size cooling tower. The VAWT performance is increased in the range of 7–8% with the integration of enclosure. There is no significant difference in the current consumption of the fan motor between the bare cooling tower and the one with installed VAWTs. With the presence of this system, approximately 17.5 GW h/year is expected to be recovered from 3000 units of cooling towers at commercial areas, assuming the cooling tower is driven by a 7.5 kW fan motor and operates 16 h/day. This amount of recovered energy can also be translated into 13% reduction in CO 2 emission

  20. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-07-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  1. Combustion-driven oscillation in a furnace with multispud-type gas burners. 4th Report. Effects of position of secondary air guide sleeve and openness of secondary air guide vane on combustion oscillation condition; Multispud gata gas turner ni okeru nensho shindo. 4. Nijigen kuki sleeve ichi oyobi nijigen kuki vane kaido no shindo reiki ni oyobosu eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, I.; Okiura, K.; Baba, A.; Orimoto, M. [Babcock-Hitachi K.K., Tokyo (Japan)

    1994-07-25

    Effects of the position of a secondary air guide sleeve and the openness of a secondary air guide vane on combustion oscillation conditions were studied experimentally for multispud-type gas burners. Pressure fluctuation in furnaces was analyzed with the previously reported resonance factor which was proposed as an index to represent the degree of combustion oscillation. As a result, the combustion oscillation region was largely affected by both position of a guide sleeve and openness of a guide vane. As the openness having large effect on the ratio of primary and secondary air/tertiary air and the position hardly having effect on the ratio were adjusted skillfully, the burner with no combustion oscillation region was achieved in its normal operation range. In addition, as the effect of preheating combustion air was arranged with a standard flow rate or mass flow flux of air, it was suggested the combustion oscillation region due to preheating can be described with the same manner as that due to no preheating. 5 refs., 8 figs.

  2. 导叶对涡轮型垂直轴风力机气动性能的影响%Effects of guiding vanes on aerodynamic performance of vortex vertical axis wind turbine

    Institute of Scientific and Technical Information of China (English)

    原红红; 赵振宙; 郑源; 黄娟

    2013-01-01

    To overcome the problem of low efficiency of the traditional vertical axis wind turbine, the structural advantages of the wind turbine with guiding vanes are introduced and the effects of guiding vanes on the vortex vertical axis wind turbine are analyzed in detail. Based on computational fluid dynamics theory, the slippage mesh technique and the k-ε model were used to compare the aerodynamic performance of the vortex vertical axis wind turbine with and without guiding vanes at a design velocity of 12 m/s. Studies have shown that the guiding vanes can effectively prevent the direct impact of the coming flow from acting on the suction section of the blade in the upwind area so as to decrease the drag torque, while the guiding vanes also negatively affect the performance of blades in the downwind area, but the positive effect of the former is more significant, so the performance of a wind turbine with guiding vanes greatly improves. The vortex vertical axis wind turbine with arc-type guiding vanes has a wider operating range, higher optimum tip speed ratio, and higher aerodynamic efficiency. The maximum wind power coefficient can reach 0.24 .%针对传统垂直轴风力机效率低的缺陷,阐述带导叶垂直轴风力机的结构优势,并分析导叶对涡轮型垂直轴风力机的作用。应用计算流体力学理论,在设计风速12 m/s下,采用滑移网格技术及k-着模型对有、无导叶两种涡轮型垂直轴风力机的气动性能进行比较。研究表明,导叶可以有效降低由于来流对逆风区叶片吸力面的直接冲击而造成的阻力扭矩,也会负面影响顺风区叶片的性能,但其负作用效果远不及在逆风区挡流降阻的正作用效果,故加导叶后风轮的性能会有很大提高。带弧线形导叶涡轮型垂直轴风力机最大风能利用系数可达0.24,具有工作范围广、最佳尖速比大的特点。

  3. Mixing vane grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Galbraith, K.P.

    1978-01-01

    An improved mixing vane grid spacer having enhanced flow mixing capability by virtue of mixing vanes being positioned at welded intersecting joints of the spacer wherein each mixing vane has an opening or window formed therein substantially directly over the welded joint to provide improved flow mixing capability is described. Some of the vanes are slotted, depending on their particular location in the spacers. The intersecting joints are welded by initially providing consumable tabs at and within each window, which are consumed during the welding of the spacer joints

  4. Optimization of submerged vane parameters

    Indian Academy of Sciences (India)

    H Sharma

    the height or length of the submerged vane, no effective change in bed profile .... easily and again vanes will be ineffective, which is what. Odgaard and .... [3] Odgaard A J and Wang Y 1991a Sediment management with submerged vanes.

  5. Rumsansning mellem vane og oplevelse

    DEFF Research Database (Denmark)

    Reeh, Henrik

    2004-01-01

    Walter Benjamin, Steen Eiler Rasmussen, arkitektur, sansning, vane, taktilitet, oplevelse, erfaring, Rom......Walter Benjamin, Steen Eiler Rasmussen, arkitektur, sansning, vane, taktilitet, oplevelse, erfaring, Rom...

  6. [Value of a novel categorization of congenital double-outlet right ventricle on guiding the choice of surgical approaches].

    Science.gov (United States)

    Pang, Kunjing; Meng, Hong; Wang, Hao; Hu, Shengshou; Hua, Zhongdong; Pan, Xiangbin; Li, Shoujun

    2015-11-01

    To explore the feasibility and value of a new categorization of double outlet right ventricular (DORV) on guiding the optimal choices of surgical approaches. Five hundred and twenty one DORV patients diagnosed by echocardiography, angiocardiography and CT at Fuwai Hospital from May 2003 to September 2014 were enrolled in this retrospective study. Congenital DORV was categorized according to three basic factors as follows: the positional relationships of great arteries (normal relation or abnormal relation), the relationships of the ventricular septal defect (VSD) to the great arteries (committed VSD or remote VSD), the presence or absence of pulmonary outflow tract obstruction (POTO). Eight types of DORV were established: type I (normal relation, committed VSD, without POTO), type II (normal relation, committed VSD, POTO), type III (normal relation, remote VSD, without POTO), type IV (normal relation, remote VSD, POTO), type V (abnormal relation, committed VSD, without POTO), type VI (abnormal relation, committed VSD, POTO), type VII (abnormal relation, remote VSD, without POTO), type VIII (abnormal relation, remote VSD, POTO). Feasibility of this classification and the value of this classification on guiding the choice of surgical approaches were analyzed. Among the five hundred and twenty one patients, there were 90 patients (17.3%) with type I DORV, 94 patients (18.0%) with type II, 33 patients (6.3%) with type III, 34 patients (6.5%) with type IV, 64 patients (12.3%) with type V, 61 patients (11.7%) with type VI, 33 patients (6.3%) with type VII, 112 patients (21.5%) with type VIII. Thus, all patients could be typed by this classification method. The echocardiography diagnosis was consistent with the intra-operative and or cardiac catheterization/CT findings. Excluding the contraindications of bi-ventricular repair, different surgical approaches were performed in every subtype of DORV according the classification, which indicated that this novel categorization

  7. The method of the gas-dynamic centrifugal compressor stage characteristics recalculation for variable rotor rotational speeds and the rotation angle of inlet guide vanes blades if the kinematic and dynamic similitude conditions are not met

    Science.gov (United States)

    Vanyashov, A. D.; Karabanova, V. V.

    2017-08-01

    A mathematical description of the method for obtaining gas-dynamic characteristics of a centrifugal compressor stage is proposed, taking into account the control action by varying the rotor speed and the angle of rotation of the guide vanes relative to the "basic" characteristic, if the kinematic and dynamic similitude conditions are not met. The formulas of the correction terms for the non-dimensional coefficients of specific work, consumption and efficiency are obtained. A comparative analysis of the calculated gas-dynamic characteristics of a high-pressure centrifugal stage with experimental data is performed.

  8. Experimental study of complex flow and turbulence structure around a turbomachine rotor blade operating behind a row of Inlet Guide Vanes (IGVS)

    Science.gov (United States)

    Soranna, Francesco

    The flow and turbulence around a rotor blade operating downstream of a row of Inlet Guide Vanes (IGV) are investigated experimentally in a refractive index matched turbomachinery facility that provides unobstructed view of the entire flow field. High resolution 2D and Stereoscopic PIV measurements are performed both at midspan and in the tip region of the rotor blade, focusing on effects of wake-blade, wake-boundary-layer and wake-wake interactions. We first examine the modification to the shape of an IGV-wake as well as to the spatial distribution of turbulence within it as the wake propagates along the rotor blade. Due to the spatially non-uniform velocity distribution, the IGV wake deforms through the rotor passage, expanding near the leading edge and shrinking near the trailing edge. The turbulence within this wake becomes spatially non-uniform and highly anisotropic as a result of interaction with the non-uniform strain rate field within the rotor passage. Several mechanisms, which are associated with rapid straining and highly non-uniform production rate (P), including negative production on the suction side of the blade, contribute to the observed trends. During IGV-wake impingement, the suction side boundary layer near the trailing edge becomes significantly thinner, with lower momentum thickness and more stable profile compared to other phases at the same location. Analysis of available terms in the integral momentum equation indicates that the phase-averaged unsteady term is the main contributor to the decrease in momentum thickness within the impinging wake. Thinning of the boundary/shear layer extends into the rotor near wake, making it narrower and increasing the phase averaged shear velocity gradients and associated production term just downstream of the trailing edge. Consequently, the turbulent kinetic energy (TKE) increases causing as much as 75% phase-dependent variations in peak TKE magnitude. Further away from the blade, the rotor wake is bent

  9. An Experimental and Numerical Investigation of Endwall Aerodynamics and Heat Transfer in a Gas Turbine Nozzle Guide Vane with Slot Film Cooling

    Science.gov (United States)

    Alqefl, Mahmood Hasan

    In many regions of the high-pressure gas turbine, film cooling flows are used to protect the turbine components from the combustor exit hot gases. Endwalls are challenging to cool because of the complex system of secondary flows that disturb surface film coolant coverage. The secondary flow vortices wash the film coolant from the surface into the mainstream significantly decreasing cooling effectiveness. In addition to being effected by secondary flow structures, film cooling flow can also affect these structures by virtue of their momentum exchange. In addition, many studies in the literature have shown that endwall contouring affects the strength of passage secondary flows. Therefore, to develop better endwall cooling schemes, a good understanding of passage aerodynamics and heat transfer as affected by interactions of film cooling flows with secondary flows is required. This experimental and computational study presents results from a linear, stationary, two-passage cascade representing the first stage nozzle guide vane of a high-pressure gas turbine with an axisymmetrically contoured endwall. The sources of film cooling flows are upstream combustor liner coolant and endwall slot film coolant injected immediately upstream of the cascade passage inlet. The operating conditions simulate combustor exit flow features, with a high Reynolds number of 390,000 and approach flow turbulence intensity of 11% with an integral length scale of 21% of the chord length. Measurements are performed with varying slot film cooling mass flow to mainstream flow rate ratios (MFR). Aerodynamic effects are documented with five-hole probe measurements at the exit plane. Heat transfer is documented through recovery temperature measurements with a thermocouple. General secondary flow features are observed. Total pressure loss measurements show that varying the slot film cooling MFR has some effects on passage loss. Velocity vectors and vorticity distributions show a very thin, yet intense

  10. Gas turbine vane platform element

    Science.gov (United States)

    Campbell, Christian X [Oviedo, FL; Schiavo, Anthony L [Oviedo, FL; Morrison, Jay A [Oviedo, FL

    2012-08-28

    A gas turbine CMC shroud plate (48A) with a vane-receiving opening (79) that matches a cross-section profile of a turbine vane airfoil (22). The shroud plate (48A) has first and second curved circumferential sides (73A, 74A) that generally follow the curves of respective first and second curved sides (81, 82) of the vane-receiving opening. Walls (75A, 76A, 77A, 78A, 80, 88) extend perpendicularly from the shroud plate forming a cross-bracing structure for the shroud plate. A vane (22) may be attached to the shroud plate by pins (83) or by hoop-tension rings (106) that clamp tabs (103) of the shroud plate against bosses (105) of the vane. A circular array (20) of shroud plates (48A) may be assembled to form a vane shroud ring in which adjacent shroud plates are separated by compressible ceramic seals (93).

  11. Heat pipe turbine vane cooling

    Energy Technology Data Exchange (ETDEWEB)

    Langston, L.; Faghri, A. [Univ. of Connecticut, Storrs, CT (United States)

    1995-10-01

    The applicability of using heat pipe principles to cool gas turbine vanes is addressed in this beginning program. This innovative concept involves fitting out the vane interior as a heat pipe and extending the vane into an adjacent heat sink, thus transferring the vane incident heat transfer through the heat pipe to heat sink. This design provides an extremely high heat transfer rate and an uniform temperature along the vane due to the internal change of phase of the heat pipe working fluid. Furthermore, this technology can also eliminate hot spots at the vane leading and trailing edges and increase the vane life by preventing thermal fatigue cracking. There is also the possibility of requiring no bleed air from the compressor, and therefore eliminating engine performance losses resulting from the diversion of compressor discharge air. Significant improvement in gas turbine performance can be achieved by using heat pipe technology in place of conventional air cooled vanes. A detailed numerical analysis of a heat pipe vane will be made and an experimental model will be designed in the first year of this new program.

  12. Double Outlet Right Ventricle

    Science.gov (United States)

    ... Right Ventricle Menu Topics Topics FAQs Double Outlet Right Ventricle Double outlet right ventricle (DORV) is a rare form of congenital heart disease. En español Double outlet right ventricle (DORV) is a rare form of congenital ...

  13. Study on Orbital Liquid Transport and Interface Behavior in Vane Tank

    Science.gov (United States)

    Kang, Qi; Rui, Wei

    2016-07-01

    Liquid propellant tank is used to supply gas free liquid for spacecraft as an important part of propulsion system. The liquid behavior dominated by surface tension in microgravity is obviously different with that on the ground, which put forward a new challenge to the liquid transport and relocation. The experiments which are investigated at drop tower in National Microgravity Lab have concentrated on liquid relocation following thruster firing. Considered that the liquid located at the bottom in the direction of the acceleration vector, a sphere scale vane tank is used to study the liquid-gas interface behaviors with different acceleration vector and different filling independently and we obtain a series of stable equilibrium interface and relocation time. We find that there is an obvious sedimentation in the direction of acceleration vector when fill rate greater than 2% fill. Suggestions have been put forward that outer vanes transferring liquid to the outlet should be fixed and small holes should be dogged at the vane close to the center post to improve the liquid flow between different vanes when B0 is greater than 2.5. The research about liquid transport alone ribbon vanes is simulated though software Flow3D. The simulation process is verified by comparing the liquid lip and vapor-liquid interface obtained from drop tower experiment and simulation result when fill rate is 15%. Then the influence of fill rate, numbers of vanes and the gap between vane and wall is studied through the same simulate process. Vanes' configurations are also changed to study the effect on the lip and liquid volume below some section. Some suggestions are put forward for the design of vanes.

  14. Solar updraft power generator with radial and curved vanes

    Science.gov (United States)

    Hafizh, Hadyan; Hamsan, Raziff; Zamri, Aidil Azlan Ahmad; Keprawi, Mohamad Fairuz Mohamad; Shirato, Hiromichi

    2018-02-01

    Solar radiation is the largest source of energy available on earth and the solar updraft power generator (SUPG) is a renewable energy facility capable of harnessing its abundant power. Unlike the conventional wind turbines that harness natural wind in the atmosphere and often encounter with the intermittent issue or even complete cut-off from airflow, the SUPG creates artificial wind as a result of solar-induced convective flows. However, the SUPG has an inherent low total efficiency due to the conversion of thermal energy into pressure energy. Acknowledging the low efficiency and considering its potential as a renewable energy facility, the current work aims to increase the total efficiency by installing a series of guide walls inside the collector. Two types of guide walls were used i.e. radial and curved vanes. The result with curved vanes showed that the updraft velocity is higher compare to those without vanes. About 18% and 64% improvement of updraft velocity and mechanical power were attained respectively. Furthermore, it was observed that the role of radial vanes configuration was more to produce a smooth updraft velocity profile rather than increasing the total efficiency.

  15. Design and Analysis of a Split Deswirl Vane in a Two-Stage Refrigeration Centrifugal Compressor

    Directory of Open Access Journals (Sweden)

    Jeng-Min Huang

    2014-09-01

    Full Text Available This study numerically investigated the influence of using the second row of a double-row deswirl vane as the inlet guide vane of the second stage on the performance of the first stage in a two-stage refrigeration centrifugal compressor. The working fluid was R134a, and the turbulence model was the Spalart-Allmaras model. The parameters discussed included the cutting position of the deswirl vane, the staggered angle of two rows of vane, and the rotation angle of the second row. The results showed that the performance of staggered angle 7.5° was better than that of 15° or 22.5°. When the staggered angle was 7.5°, the performance of cutting at 1/3 and 1/2 of the original deswirl vane length was slightly different from that of the original vane but obviously better than that of cutting at 2/3. When the staggered angle was 15°, the cutting position influenced the performance slightly. At a low flow rate prone to surge, when the second row at a staggered angle 7.5° cutting at the half of vane rotated 10°, the efficiency was reduced by only about 0.6%, and 10% of the swirl remained as the preswirl of the second stage, which is generally better than other designs.

  16. Static pressure recovery analysis in the vane island diffuser of a centrifugal pump

    Energy Technology Data Exchange (ETDEWEB)

    Si, Qiaorui [National Research Center of Pumps, Jiangsu University, Zhenjiang (China); Dupont, Patrick; Bayeul-Laine, Annie-Claude; Dazin, Antoine; Roussette, Olivier; Bois, Gerard [LML, UMR CNRS 8107 Ecole Centrale de Lille, Lille (France)

    2016-02-15

    The overall performance of a vane-island type diffuser of a centrifugal pump model was obtained by means of directional probe traverses. These measurements were performed in an air model of a real hydraulic pump for five volume flow rates. Directional probe traverses are performed with a classical three-hole probe to cover most of the complete inlet section of the diffuser from hub to shroud and from pressure to suction side. Existing Particle image velocimetry (PIV) measurement results are also used to compare probe measurement results between the inlet and outlet throats of vane island diffuser at mid-span. Some assistance from already existing unsteady calculation, including leakage effects, is used to evaluate the numerical approach capability and to correctly define the mean initial conditions at impeller's outlet section. Pressure recovery and the measured total pressure loss levels inside this particular vane diffuser geometry are then calculated. Detailed analysis of the flow structure at the inlet section of the vane island diffuser is presented to focus on pressure evolution inside the entire diffuser section for different flow rates. The combined effects of incidence angle and blockage distributions along hub to shroud direction are found to play an important role on loss distribution in such a diffuser.

  17. An analytical model for droplet separation in vane separators and measurements of grade efficiency and pressure drop

    International Nuclear Information System (INIS)

    Koopman, Hans K.; Köksoy, Çağatay; Ertunç, Özgür; Lienhart, Hermann; Hedwig, Heinz; Delgado, Antonio

    2014-01-01

    Highlights: • An analytical model for efficiency is extended with additional geometrical features. • A simplified and a novel vane separator design are investigated experimentally. • Experimental results are significantly affected by re-entrainment effects. • Outlet droplet size spectra are accurately predicted by the model. • The improved grade efficiency doubles the pressure drop. - Abstract: This study investigates the predictive power of analytical models for the droplet separation efficiency of vane separators and compares experimental results of two different vane separator geometries. The ability to predict the separation efficiency of vane separators simplifies their design process, especially when analytical research allows the identification of the most important physical and geometrical parameters and can quantify their contribution. In this paper, an extension of a classical analytical model for separation efficiency is proposed that accounts for the contributions provided by straight wall sections. The extension of the analytical model is benchmarked against experiments performed by Leber (2003) on a single stage straight vane separator. The model is in very reasonable agreement with the experimental values. Results from the analytical model are also compared with experiments performed on a vane separator of simplified geometry (VS-1). The experimental separation efficiencies, computed from the measured liquid mass balances, are significantly below the model predictions, which lie arbitrarily close to unity. This difference is attributed to re-entrainment through film detachment from the last stage of the vane separators. After adjustment for re-entrainment effects, by applying a cut-off filter to the outlet droplet size spectra, the experimental and theoretical outlet Sauter mean diameters show very good agreement. A novel vane separator geometry of patented design (VS-2) is also investigated, comparing experimental results with VS-1

  18. Solar energy system with wind vane

    Science.gov (United States)

    Grip, Robert E

    2015-11-03

    A solar energy system including a pedestal defining a longitudinal axis, a frame that is supported by the pedestal and that is rotateable relative to the pedestal about the longitudinal axis, the frame including at least one solar device, and a wind vane operatively connected to the frame to urge the frame relative to the pedestal about the longitudinal axis in response to wind acting on the wind vane.

  19. Analytical solution for the electrical properties of a radio-frequency quadrupole (RFQ) with simple vanes

    International Nuclear Information System (INIS)

    Lancaster, H.

    1982-01-01

    Although the SUPERFISH program is used for calculating the design parameters of an RFQ structure with complex vanes, an analytical solution for electrical properties of an RFQ with simple vanes provides insight into the parametric behavior of these more complicated resonators. The fields in an inclined plane wave guide with proper boundary conditions match those in one quadrant of an RFQ. The principle of duality is used to exploit the solutions to a radial transmission line in solving the field equations. Calculated are the frequency equation, frequency sensitivity factors, electric field, magnetic field, stored energy (U), power dissipation, and quality factor

  20. Design Concepts for Cooled Ceramic Matrix Composite Turbine Vanes

    Science.gov (United States)

    Boyle, Robert

    2014-01-01

    This project demonstrated that higher temperature capabilities of ceramic matrix composites (CMCs) can be used to reduce emissions and improve fuel consumption in gas turbine engines. The work involved closely coupling aerothermal and structural analyses for the first-stage vane of a high-pressure turbine (HPT). These vanes are actively cooled, typically using film cooling. Ceramic materials have structural and thermal properties different from conventional metals used for the first-stage HPT vane. This project identified vane configurations that satisfy CMC structural strength and life constraints while maintaining vane aerodynamic efficiency and reducing vane cooling to improve engine performance and reduce emissions. The project examined modifications to vane internal configurations to achieve the desired objectives. Thermal and pressure stresses are equally important, and both were analyzed using an ANSYS® structural analysis. Three-dimensional fluid and heat transfer analyses were used to determine vane aerodynamic performance and heat load distributions.

  1. Split coaxial RFQ structure with modulated vanes

    International Nuclear Information System (INIS)

    Arai, S.

    1983-10-01

    A new split coaxial RFO structure with modulated vanes is proposed. The structure is designed to accelerate 238 U 4+ from 1.68 keV/u to 45.1 keV/u at frequency of 12.5 MHz. The cavity is 1.6 m in diameter and 8 m in length. The cavity consists of four cavity modules divided by three stems which support horizontal and vertical vanes periodically and alternatively. At the same time, problems on the beam dynamics and design procedures are described and discussed. (orig.)

  2. AGU hydrology publication outlets

    Science.gov (United States)

    Freeze, R. Allan

    In recent months I have been approached on several occasions by members of the hydrology community who asked me which of the various AGU journals and publishing outlets would be most suitable for a particular paper or article that they have prepared.Water Resources Research (WRR) is the primary AGU outlet for research papers in hydrology. It is an interdisciplinary journal that integrates research in the social and natural sciences of water. The editors of WRR invite original contributions in the physical, chemical and biological sciences and also in the social and policy sciences, including economics, systems analysis, sociology, and law. The editor for the physical sciences side of the journal is Donald R. Nielson, LAWR Veihmeyer Hall, University of California Davis, Davis, CA 95616. The editor for the policy sciences side of the journal is Ronald G. Cummings, Department of Economics, University of New Mexico, Albuquerque, NM 87131

  3. Precision Model for Microwave Rotary Vane Attenuator

    DEFF Research Database (Denmark)

    Guldbrandsen, Tom

    1979-01-01

    A model for a rotary vane attenuator is developed to describe the attenuator reflection and transmission coefficients in detail. All the parameters of the model can be measured in situ, i.e., without diassembling any part. The tranmission errors caused by internal reflections are calculated from ...

  4. CMC vane assembly apparatus and method

    Science.gov (United States)

    Schiavo, Anthony L; Gonzalez, Malberto F; Huang, Kuangwei; Radonovich, David C

    2012-10-23

    A metal vane core or strut (64) is formed integrally with an outer backing plate (40). An inner backing plate (38) is formed separately. A spring (74) with holes (75) is installed in a peripheral spring chamber (76) on the strut. Inner and outer CMC shroud covers (46, 48) are formed, cured, then attached to facing surfaces of the inner and outer backing plates (38, 40). A CMC vane airfoil (22) is formed, cured, and slid over the strut (64). The spring (74) urges continuous contact between the strut (64) and airfoil (66), eliminating vibrations while allowing differential expansion. The inner end (88) of the strut is fastened to the inner backing plate (38). A cooling channel (68) in the strut is connected by holes (69) along the leading edge of the strut to peripheral cooling paths (70, 71) around the strut. Coolant flows through and around the strut, including through the spring holes.

  5. Vane coupling rings: a simple technique for stabilizing a four-vane radiofrequency quadrupole structure

    International Nuclear Information System (INIS)

    Howard, D.; Lancaster, H.

    1983-01-01

    The benefits of stabilized accelerating structures, with regard to the manufacture and operation, have been well documented. The four-vane radiofrequency quadrupoles (RFQ) presently being designed and constructed in many laboratories are not stabilized because of the weak electromagnetic coupling between the quadrant resonators. This paper presents a simple technique developed at the Lawrence Berkeley Laboratory using vane coupling rings (VCR's) which azimuthally stabilize the RFQ structure and greatly enhance its use as a practical accelerator. In particular, the VCR's: Completely eliminate the dipole modes in the frequency range of interest; Provide adequate quadrant balance with an initial precision mechanical alignment of the vanes; Enhance axial balance and simplify end tuners. Experimental verification tests on a scale model will be discussed

  6. Vane coupling rings: a simple technique for stabilizing a four-vane radiofrequency quadrupole structure

    International Nuclear Information System (INIS)

    Howard, D.; Lancaster, H.

    1982-11-01

    The benefits of stabilized accelerating structures, with regard to the manufacture and operation, have been well documented. The four-vane radiofrequency quadrupoles (RFQ) presently being designed and constructed in many laboratories are not stabilized because of the weak electromagnetic coupling between the quadrant resonators. This paper presents a simple technique developed at the Lawrence Berkeley Laboratory using vane coupling rings (VCR's) which azimuthally stabilize the RFQ structure and greatly enhance its use as a practical accelerator. In particular, the VCR's: completely eliminate the dipole modes in the frequency range of interest; provide adequate quadrant balance with an initial precision mechanical alignment of the vanes; and enhance axial balance and simplify end tuners. Experimental verification tests on a scale model are discussed

  7. Vane-Cam - camshaft controls with new functionalities; Vane-Cam - Nockenwellenversteller mit neuen Funktionalitaeten

    Energy Technology Data Exchange (ETDEWEB)

    Knecht, A.; Pohl, D. [Hydraulik-Ring GmbH, Nuertingen (Germany); Hannibal, W. [Fachhochschule Suedwestfalen, Iserlohn (Germany). Labor fuer Konstruktion und CAE-Anwendungen; enTec Consulting GmbH, Hemer (Germany)

    2007-01-15

    Infinitely variable camshaft phasing systems will be used in the future in practically all gasoline internal combustion engines high volume production. This paper of Hydraulik-Ring GmbH gives an overview of the current system concepts of the latest generation of camshaft controls utilizing the principle of the vane motor. (orig.)

  8. Vane clocking effects in an embedded compressor stage

    Science.gov (United States)

    Key, Nicole Leanne

    The objective of this research was to experimentally investigate the effects of vane clocking, the circumferential indexing of adjacent vane rows with similar vane counts, in an embedded compressor stage. Experiments were performed in the Purdue 3-Stage Compressor, which consists of an IGV followed by three stages. The IGV, Stator 1, and Stator 2 have identical vane counts of 44, and the effects of clocking were studied on Stage 2. The clocking configuration that located the upstream vane wake on the Stator 2 leading edge was identified with total pressure measurements at the inlet to Stator 2 and confirmed with measurements at the exit of Stator 2. For both loading conditions, the total temperature results showed that there was no measurable change associated with vane clocking in the amount of work done on the flow. At design loading, the change in stage efficiency with vane clocking was 0.27 points between the maximum and minimum efficiency clocking configurations. The maximum efficiency configuration was the case where the Stator 1 wake impinged on the Stator 2 leading edge. This condition produced a shallower and thinner Stator 2 wake compared to the clocking configuration that located the wake in the middle of the Stator 2 passage. By locating the Stator 1 wake at the leading edge, it dampened the Stator 2 boundary layer response to inlet fluctuations associated with the Rotor 2 wakes. At high loading, the change in Stage 2 efficiency increased to 1.07 points; however, the maximum efficiency clocking configuration was the case where the Stator 1 wake passed through the middle of the downstream vane passage. At high loading, the flow physics associated with vane clocking were different than at design loading because the location of the Stator 1 wake fluid on the Stator 2 leading edge triggered a boundary layer separation on the suction side of Stator 2 producing a wider and deeper wake. Vane clocking essentially affects the amount of interaction between the

  9. A horizontal vane radiometer: Experiment, theory, and simulation

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, David; Larraza, Andres, E-mail: larraza@nps.edu [Department of Physics, Naval Postgraduate School, Monterey, California 93940 (United States); Garcia, Alejandro [Department of Physics and Astronomy, San Jose State University, San Jose, California 95152 (United States)

    2016-03-15

    The existence of two motive forces on a Crookes radiometer has complicated the investigation of either force independently. The thermal creep shear force in particular has been subject to differing interpretations of the direction in which it acts and its order of magnitude. In this article, we provide a horizontal vane radiometer design which isolates the thermal creep shear force. The horizontal vane radiometer is explored through experiment, kinetic theory, and the Direct Simulation Monte Carlo (DSMC) method. The qualitative agreement between the three methods of investigation is good except for a dependence of the force on the width of the vane even when the temperature gradient is narrower than the vane which is present in the DSMC method results but not in the theory. The experimental results qualitatively resemble the theory in this regard. The quantitative agreement between the three methods of investigation is better than an order of magnitude in the cases examined. The theory is closer to the experimental values for narrow vanes and the simulations are closer to the experimental values for the wide vanes. We find that the thermal creep force acts from the hot side to the cold side of the vane. We also find the peak in the radiometer’s angular speed as a function of pressure is explained as much by the behavior of the drag force as by the behavior of the thermal creep force.

  10. A horizontal vane radiometer: Experiment, theory, and simulation

    International Nuclear Information System (INIS)

    Wolfe, David; Larraza, Andres; Garcia, Alejandro

    2016-01-01

    The existence of two motive forces on a Crookes radiometer has complicated the investigation of either force independently. The thermal creep shear force in particular has been subject to differing interpretations of the direction in which it acts and its order of magnitude. In this article, we provide a horizontal vane radiometer design which isolates the thermal creep shear force. The horizontal vane radiometer is explored through experiment, kinetic theory, and the Direct Simulation Monte Carlo (DSMC) method. The qualitative agreement between the three methods of investigation is good except for a dependence of the force on the width of the vane even when the temperature gradient is narrower than the vane which is present in the DSMC method results but not in the theory. The experimental results qualitatively resemble the theory in this regard. The quantitative agreement between the three methods of investigation is better than an order of magnitude in the cases examined. The theory is closer to the experimental values for narrow vanes and the simulations are closer to the experimental values for the wide vanes. We find that the thermal creep force acts from the hot side to the cold side of the vane. We also find the peak in the radiometer’s angular speed as a function of pressure is explained as much by the behavior of the drag force as by the behavior of the thermal creep force.

  11. Demonstration and Field Evaluation of Streambank Stabilization with Submerged Vanes

    Science.gov (United States)

    Whitman, H.; Hoopes, J.; Poggi, D.; Fitzpatrick, F.; Walz, K.; ,

    2001-01-01

    The effectiveness of submerged vanes for reducing bank erosion and improving aquatic habitat is being evaluated at a site on North Fish Creek, a Lake Superior tributary. Increased runoff from agricultural areas with clayey soils has increased flood magnitudes and the erosion potential/transport capacity of the stream. Most of the creek's sediment load originates from the erosion of 17 large bluffs. This creek contains important recreational fisheries that are potentially limited by the loss of aquatic habitat from deposition of sediment on spawning beds. Submerged vanes are a cost effective and environmentally less intrusive alternative to traditional structural stabilization measures. Submerged vanes protrude from a channel bed, are oriented at an angle to the local velocity, and are distributed along a portion of channel. They induce a transverse force and torque on the flow along with longitudinal vortexes that alter the cross sectional shape and alignment of the channel. Submerged vanes were installed at a bluff/bend site in summer and fall 2000. The number, size, and layout of the vanes were based upon the channel morphology under estimated bankfull conditions. The effectiveness of the vanes will be evaluated by comparing surveys of the bluff face, streamflow, and channel conditions for several years after installation of the submerged vanes with surveys before and immediately after their installation.

  12. Sequential cooling insert for turbine stator vane

    Science.gov (United States)

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  13. Smart actuation of inlet guide vanes for small turbine engine

    Science.gov (United States)

    Rusovici, Razvan; Kwok Choon, Stephen T.; Sepri, Paavo; Feys, Joshuo

    2011-04-01

    Unmanned Aerial Vehicles (UAVs) have gained popularity over the past few years to become an indispensable part of aerial missions that include reconnaissance, surveillance, and communication [1]. As a result, advancements in small jet-engine performance are needed to increase the performance (range, payload and efficiency) of the UAV. These jet engines designed especially for UAV's are characterized by thrust force on the order of 100N and due to their size and weight limitations, may lack advanced flow control devices such as IGV [2]. The goal of the current study was to present a conceptual design of an IGV smart-material based actuation mechanism that would be simple, compact and lightweight. The compressor section of an engine increases the pressure and conditions the flow before the air enters the combustion chamber [3]. The airflow entering the compressor is often turbulent due to the high angle of incidence between engine inlet and free-stream velocity, or existing atmospheric turbulence. Actuated IGV are used to help control the relative angle of incidence of the flow that enters the engine compressor, thereby preventing flow separation, compressor stall and thus extending the compressor's operating envelope [4]. Turbine jet- engines which employ variable IGV were developed by Rolls Royce (Trent DR-900) and General Electric (J79).

  14. Optimization of a Low Heat Load Turbine Nozzle Guide Vane

    National Research Council Canada - National Science Library

    Johnson, Jamie J

    2006-01-01

    .... However, future aircraft systems require ever increasing levels of gas-turbine inlet temperature causing the durability and reliability of turbine components to be an ever more important design concern...

  15. Robust optimization of supersonic ORC nozzle guide vanes

    Science.gov (United States)

    Bufi, Elio A.; Cinnella, Paola

    2017-03-01

    An efficient Robust Optimization (RO) strategy is developed for the design of 2D supersonic Organic Rankine Cycle turbine expanders. The dense gas effects are not-negligible for this application and they are taken into account describing the thermodynamics by means of the Peng-Robinson-Stryjek-Vera equation of state. The design methodology combines an Uncertainty Quantification (UQ) loop based on a Bayesian kriging model of the system response to the uncertain parameters, used to approximate statistics (mean and variance) of the uncertain system output, a CFD solver, and a multi-objective non-dominated sorting algorithm (NSGA), also based on a Kriging surrogate of the multi-objective fitness function, along with an adaptive infill strategy for surrogate enrichment at each generation of the NSGA. The objective functions are the average and variance of the isentropic efficiency. The blade shape is parametrized by means of a Free Form Deformation (FFD) approach. The robust optimal blades are compared to the baseline design (based on the Method of Characteristics) and to a blade obtained by means of a deterministic CFD-based optimization.

  16. Bladder outlet obstruction due to a small midline prostatic cyst - diagnostic imaging and interventional radiological treatment

    International Nuclear Information System (INIS)

    Hueppe, T.; Kopka, L.; Friedrich, M.; Kuehn, M.

    1992-01-01

    We describe a rare case of a bladder outlet obstruction due to a midline prostatic cyst. In the following clinical apperance, diagnostic imaging and therapy by CT-guided punction are reported. Differential diagnosis and therapy are discussed. (orig.) [de

  17. Thoracic outlet syndrome: Case report

    International Nuclear Information System (INIS)

    Marquez, Juan Camilo; Acosta, Mauricio Fernando; Uribe Jorge Ricardo

    2009-01-01

    We report a case of vascular thoracic outlet syndrome in a young man, diagnosed with upper limb arteriography, leading to repeated arterio-arterial emboli originating from a post-stenotic subclavian artery aneurysm. It is of our interest due to its low incidence and the small number of cases reported that have been diagnosed by arteriography. The thoracic outlet is the path through which vascular and neural structures goes from the neck to the axilla, and it has three anatomical strictures, that when pronounced, can compress the brachial plexus or subclavian vessels, leading to different symptoms and signs.

  18. Optimization analysis of a new vane MRF damper

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J Q; Feng, Z Z; Jing, Q [Department of Technical Support Engineering, Academy of Armored Force Engineering, Beijing, 100072 (China)], E-mail: zhangjq63@yahoo.com.cn

    2009-02-01

    The primary purpose of this study was to provide the optimization analysis certain characteristics and benefits of a vane MRF damper. Based on the structure of conventional vane hydraulic damper for heavy vehicle, a narrow arc gap between clapboard and rotary vane axle, which one rotates relative to the other, was designed for MRF valve and the mathematical model of damping was deduced. Subsequently, the finite element analysis of electromagnetic circuit was done by ANSYS to perform the optimization process. Some ways were presented to augment the damping adjustable multiple under the condition of keeping initial damping forces and to increase fluid dwell time through the magnetic field. The results show that the method is useful in the design of MR dampers and the damping adjustable range of vane MRF damper can meet the requirement of heavy vehicle semi-active suspension system.

  19. Turbocharger with variable nozzle having vane sealing surfaces

    Science.gov (United States)

    Arnold, Philippe [Hennecourt, FR; Petitjean, Dominique [Julienrupt, FR; Ruquart, Anthony [Thaon les Vosges, FR; Dupont, Guillaume [Thaon les Vosges, FR; Jeckel, Denis [Thaon les Vosges, FR

    2011-11-15

    A variable nozzle for a turbocharger includes a plurality of vanes rotatably mounted on a nozzle ring and disposed in a nozzle flow path defined between the nozzle ring and an opposite nozzle wall. Either or both of the faces of the nozzle ring and nozzle wall include(s) at least one step that defines sealing surfaces positioned to be substantially abutted by airfoil surfaces of the vanes in the closed position of the vanes and to be spaced from the airfoil surfaces in positions other than the closed position. This substantial abutment between the airfoil surfaces and the sealing surfaces serves to substantially prevent exhaust gas from leaking past the ends of the airfoil portions. At the same time, clearances between the nozzle ring face and the end faces of the airfoil portions can be sufficiently large to prevent binding of the vanes under all operating conditions.

  20. Bed erosion control at 60 degree river confluence using vanes

    Science.gov (United States)

    Wuppukondur, Ananth; Chandra, Venu

    2017-04-01

    Confluences are common occurrences along natural rivers. Hydrodynamics at the confluence is complex due to merging of main and lateral flows with different characteristics. Bed erosion occurs at the confluence due to turbulence and also secondary circulation induced by centrifugal action of the lateral flow. The eroded sediment poses various problems in the river ecosystem including river bank failure. Reservoirs are majorly affected due to sediment deposition which reduces storage capacity. The bed erosion also endangers stability of pipeline crossings and bridge piers. The aim of this experimental study is to check the performance of vanes in controlling bed erosion at the confluence. Experiments are performed in a 600 confluence mobile bed model with a non-uniform sediment of mean particle size d50 = 0.28mm. Discharge ratio (q=ratio of lateral flow discharge to main flow discharge) is maintained as 0.5 and 0.75 with a constant average main flow depth (h) of 5cm. Vanes of width 0.3h (1.5cm) and thickness of 1 mm are placed along the mixing layer at an angle of 150, 300 and 600(with respect to main flow) to perform the experiments. Also, two different spacing of 2h and 3h (10cm and 15cm) between the vanes are used for conducting the experiments. A digital point gauge with an accuracy of ±0.1mm is used to measure bed levels and flow depths at the confluence. An Acoustic Doppler Velocitimeter (ADV) with a frequency of 25Hz and accuracy of ±1mm/s is used to measure flow velocities. Maximum scour depth ratio Rmax, which is ratio between maximum scour depth (Ds) and flow depth (h), is used to present the experimental results.From the experiments without vanes, it is observed that the velocities are increasing along the mixing layer and Rmax=0.82 and 1.06, for q=0.5 and 0.75, respectively. The velocities reduce with vanes since roughness increases along the mixing layer. For q=0.5 and 0.75, Rmax reduces to 0.62 and 0.7 with vanes at 2h spacing, respectively. Similarly

  1. Twisted Vanes Would Enhance Fuel/Air Mixing In Turbines

    Science.gov (United States)

    Nguyen, H. Lee; Micklow, Gerald J.; Dogra, Anju S.

    1994-01-01

    Computations of flow show performance of high-shear airblast fuel injector in gas-turbine engine enhanced by use of appropriately proportioned twisted (instead of flat) dome swirl vanes. Resultant more nearly uniform fuel/air mixture burns more efficiently, emitting smaller amounts of nitrogen oxides. Twisted-vane high-shear airblast injectors also incorporated into paint sprayers, providing advantages of low pressure drop characteristic of airblast injectors in general and finer atomization of advanced twisted-blade design.

  2. A horizontal vane radiometer: experiment, theory and simulation

    OpenAIRE

    Wolfe, David; Lazarra, Andres; Garcia, Alejandro

    2015-01-01

    The existence of two motive forces on a Crookes radiometer has complicated the investigation of either force independently. The thermal creep shear force in particular has been subject to differing interpretations of the direction in which it acts and its order of magnitude. In this article we provide a horizontal vane radiometer design which isolates the thermal creep shear force. The horizontal vane radiometer is explored through experiment, kinetic theory, and the Direct Simulation Monte C...

  3. Design Concepts for Cooled Ceramic Composite Turbine Vane

    Science.gov (United States)

    Boyle, Robert J.; Parikh, Ankur H.; Nagpal, VInod K.

    2015-01-01

    The objective of this work was to develop design concepts for a cooled ceramic vane to be used in the first stage of the High Pressure Turbine(HPT). To insure that the design concepts were relevant to the gas turbine industry needs, Honeywell International Inc. was subcontracted to provide technical guidance for this work. The work performed under this contract can be divided into three broad categories. The first was an analysis of the cycle benefits arising from the higher temperature capability of Ceramic Matrix Composite(CMC) compared with conventional metallic vane materials. The second category was a series of structural analyses for variations in the internal configuration of first stage vane for the High Pressure Turbine(HPT) of a CF6 class commercial airline engine. The third category was analysis for a radial cooled turbine vanes for use in turboshaft engine applications. The size, shape and internal configuration of the turboshaft engine vanes were selected to investigate a cooling concept appropriate to small CMC vanes.

  4. The influence of the vane on the lubrication characteristics between the vane and the rolling piston of a rotary compressor

    International Nuclear Information System (INIS)

    Cho, Ihn Sung; Jung, Jae Youn

    2006-01-01

    The rolling piston type rotary compressor has been widely used for refrigeration and air -conditioning systems due to its compactness and high-speed operation. The present analysis is part of a research program directed toward maximizing the advantages of refrigerant compressors. The study of lubrication characteristics in the critical sliding component is essential for the design of refrigerant compressors. Therefore, theoretical investigation of the lubrication characteristics of a rotary compressor being used for refrigeration and air-conditioning systems was investigated. The Newton-Raphson method was used for a partial elastohydrodynamic lubrication analysis between the vane and the rolling piston of a rotary compressor. The results demonstrated that the vane thickness and the center line position of the vane significantly influenced the friction force and the energy loss between the vane and the rolling piston

  5. A lightweight, biological structure with tailored stiffness: The feather vane.

    Science.gov (United States)

    Sullivan, Tarah N; Pissarenko, Andreï; Herrera, Steven A; Kisailus, David; Lubarda, Vlado A; Meyers, Marc A

    2016-09-01

    The flying feathers of birds are keratinous appendages designed for maximum performance with a minimum weight penalty. Thus, their design contains ingenious combinations of components that optimize lift, stiffness, aerodynamics, and damage resistance. This design involves two main parts: a central shaft that prescribes stiffness and lateral vanes which allows for the capture of air. Within the feather vane, barbs branch from the shaft and barbules branch from barbs, forming a flat surface which ensures lift. Microhooks at the end of barbules hold barbs tightly together, providing the close-knit, unified structure of the feather vane and enabling a repair of the structure through the reattachment of un-hooked junctions. Both the shaft and barbs are lightweight biological structures constructed of keratin using the common motif of a solid shell and cellular interior. The cellular core increases the resistance to buckling with little added weight. Here we analyze the detailed structure of the feather barb and, for the first time, explain its flexural stiffness in terms of the mechanics of asymmetric foam-filled beams subjected to bending. The results are correlated and validated with finite element modeling. We compare the flexure of single barbs as well as arrays of barbs and find that the interlocking adherence of barbs to one another enables a more robust structure due to minimized barb rotation during deflection. Thus, the flexure behavior of the feather vane can be tailored by the adhesive hooking between barbs, creating a system that mitigates damage. A simplified three-dimensional physical model for this interlocking mechanism is constructed by additive manufacturing. The exceptional architecture of the feather vane will motivate the design of bioinspired structures with tailored and unique properties ranging from adhesives to aerospace materials. Despite its importance to bird flight, literature characterizing the feather vane is extremely limited. The feather

  6. Design Considerations for Ceramic Matrix Composite Vanes for High Pressure Turbine Applications

    Science.gov (United States)

    Boyle, Robert J.; Parikh, Ankur H.; Nagpal, Vinod K.; Halbig, Michael C.

    2013-01-01

    Issues associated with replacing conventional metallic vanes with Ceramic Matrix Composite (CMC) vanes in the first stage of the High Pressure Turbine (HPT) are explored. CMC materials have higher temperature capability than conventional HPT vanes, and less vane cooling is required. The benefits of less vane coolant are less NOx production and improved vane efficiency. Comparisons between CMC and metal vanes are made at current rotor inlet temperatures and at an vane inlet pressure of 50 atm.. CMC materials have directionally dependent strength characteristics, and vane designs must accommodate these characteristics. The benefits of reduced NOx and improved cycle efficiency obtainable from using CMC vanes. are quantified Results are given for vane shapes made of a two dimensional CMC weave. Stress components due to thermal and pressure loads are shown for all configurations. The effects on stresses of: (1) a rib connecting vane pressure and suction surfaces; (2) variation in wall thickness; and (3) trailing edge region cooling options are discussed. The approach used to obtain vane temperature distributions is discussed. Film cooling and trailing edge ejection were required to avoid excessive vane material temperature gradients. Stresses due to temperature gradients are sometimes compressive in regions where pressure loads result in high tensile stresses.

  7. A new wind vane for the measurement of atmospheric turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Parker, M.J.; Heverly, M.

    1997-02-01

    A Cooperative Research and Development Agreement (CRADA) between Met One Instruments, Incorporated (Met One) and Westinghouse Savannah River Company (WSRC) was created to develop a new wind vane that more accurately measures atmospheric turbulence. Through a process that had several phases, Met One created a prototype vane that was designed to attach to the existing Model 1585 Bi-Directional Wind Vane instrument structure. The prototype contained over 20% less mass to enhance responsiveness, which was also increased through the use of a teardrop-shaped fin structure. The prototype vane can be readily manufactured for commercial retail. Tests in wind tunnel of Building 735-7A, the Meteorological Engineering Facility, indicated that the new vane has a superior starting threshold of less than 0.14 meter per second, a delay distance of 0.72 meter, and a damping ratio of 0.4. The relative accuracy of less than one degree is unchanged from the previous design. The vane bias was acceptable at 0.8 degree for the horizontal wind angle, but was slightly high at 1.4 degree for the verticle wind angle. The high value of the verticle wind angle bias can most likely be reduced to the desired less than one degree value with standard manufacturing production techniques. The durability of the prototype vane was not tested in the field but is expected to be slightly less due to the use of hollow rather than foam-filled fins. However, the loss of some durability is more than compensated with increased sensitivity at low wind speeds. Field testing of the prototype is required to test for adequacy of durability.

  8. Influence of the Applied Working Fluid and the Arrangement of the Steering Edges on Multi-Vane Expander Performance in Micro ORC System

    Directory of Open Access Journals (Sweden)

    Józef Rak

    2018-04-01

    Full Text Available Micro-power domestic organic Rankine cycle (ORC systems are nowadays of great interest. These systems are considered for combined heat and power (CHP generation in domestic and distributed applications. The main issues of ORC systems design is selection of the expander and the working fluid. Thanks to their positive features, multi-vane expanders are especially promising for application in micro-power ORC systems. These expanders are very simple in design, small in dimensions, inexpensive and feature low gas flow capacity and expansion ratio. The application of multi-vane expanders in ORC systems is innovative and currently limited to prototype applications. However, a literature review indicates the growing interest in these machines and the potential for practical implementation. For this reason, it is necessary to conduct detailed studies on the multi-vane expanders operation in ORC systems. In this paper the results of experimental and numerical investigations on the influence of the applied working fluid and the arrangement of the steering edges on multi-vane expander performance in micro ORC system are reported. The experiments were performed using the specially designed lab test-stand, i.e. the domestic ORC system. Numerical simulations were proceeded in ANSYS CFX software (ANSYS, Inc., Canonsburg, PA, USA and were focused on determining the expander performance under various flow conditions of different working fluids. Detailed numerical analysis of the arrangement of the machine steering edges showed existence of optimal mutual position of the inlet and outlet port for which the multi-vane expander achieves maximum internal work and internal efficiency.

  9. Hydrologic Outlets of the Greenland Ice Sheet

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hydrologic Outlets of the Greenland Ice Sheet data set contains GIS point shapefiles that include 891 observed and potential hydrologic outlets of the Greenland...

  10. Extension of the Vane Pump-Grinder Technology to Manufacture Finely Dispersed Meat Batters.

    Science.gov (United States)

    Irmscher, Stefan B; Gibis, Monika; Herrmann, Kurt; Oechsle, Anja Maria; Kohlus, Reinhard; Weiss, Jochen

    2016-03-01

    A vane pump-grinder system was extended to enable the manufacture of finely dispersed emulsion-type sausages by constructing and attaching a high-shear homogenizer at the outlet. We hypothesized that the dispersing capabilities of the extended system may be improved to the point of facilitating meat-fat emulsification due to an overall increased volumetric energy input EV . Coarsely ground raw material mixtures were processed to yield meat batters at varying volume flow rates (10 to 60 L/min) and rotational rotor speeds of the homogenizer nrotor (1000 to 3400 rpm). The normalized torques acting on pump, grinder, and homogenizer motors were recorded and unit power consumptions were calculated. The structure of the manufactured meat batters and sausages were analyzed via image analysis. Key physicochemical properties of unheated and heated batters, that is, texture, water-binding, color, and solubilized protein were determined. The mean diameter d10 of the visible lean meat particles varied between 352 and 406 μm whereas the mean volume-surface diameter d32 varied between 603 and 796 μm. The lightness L* ranged from 66.2 to 70.7 and correlated with the volumetric energy input and product structure. By contrast, varying process parameters did not impact color values a* (approximately 11) and b* (approximately 8). Interestingly, water-binding and protein solubilization were not affected. An exponential process-structure relationship was identified allowing manufacturers to predict product properties as a function of applied process parameters. Raw material mixtures can be continuously comminuted, emulsified, and subsequently filled into casings using an extended vane pump-grinder. © 2016 Institute of Food Technologists®

  11. Study of the laboratory Vane test on mortars

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Elton [Post-Graduate Program in Structures and Civil Construction, Civil and Environmental Engineering Department, University of Brasilia Campus Universitario Darcy Ribeiro Asa Norte, 70910-900 Brasilia/DF (Brazil); Sousa, Jose G.G. de [Federal University of Vale do Sao Francisco, Av. Presidente Tancredo Neve, 100-56306-410 Petroline/PE (Brazil); Guimaraes, Elvio A. [University of Feira de Santana, Campus Universitario-BR 116, Km 03-44031-460-Feira de Santana/BA (Brazil); Silva, Francisco Gabriel S. [Post-Graduate Program in Structures and Civil Construction, University of Brasilia Campus Universitario Darcy Ribeiro Asa Norte, 70910-900 Brasilia/DF (Brazil)

    2007-01-15

    The Vane method (Vane test) is a simple but efficient method to measure the yield stress among other properties of non-Newtonian fluids. These fluids exhibit big flow effects in flat surfaces which are common in rheometers devices of different types (parallel disk or coaxial cylinder types). The yield stress values obtained with Vane method, in pastes, gels, soils and concentrated suspensions, have presented good agreement with results found elsewhere by most of the rheologic methods shown in the literature. The aim of this work is presenting a discussion on the capabilities of the Vane method, highlighting the theoretical basis, the functioning principle with some operational particularities, and some applications of the method in investigating the properties of fresh rendering mortars. Works of several authors that used the same method for fresh mortars were reviewed and experimental results of tests done by the authors of this paper using the method are also presented and discussed, focusing on the desirable workability for mortars. The Vane test method is an important tool in studying rheological properties in freshly applied mortar. It is able to define clear conditions in the applying of this material. (author)

  12. Pressure Drop Test of Hybrid Mixing Vane Spacer Grid

    Energy Technology Data Exchange (ETDEWEB)

    Oh, D. S.; Chang, S. K.; Kim, B. D.; Chun, S. Y.; Chun, T. H

    2007-08-15

    The pressure loss test has been accomplished in the test section containing 5x5 rod bundle with a length of 2 m including 3 spacer grids. The test has been performed for the 5 kinds of spacer grids to compare the pressure loss characteristics: 1. Plain spacer grid which has the same body of the Hybrid but without vane (Plain), 2. Hybrid Vane spacer grid (Hybrid), 3. Hybrid-SC spacer grid which is constructed with coined, chamfered strip and is fabricated by spot welding, 4. Hybrid-LC spacer grid which is constructed with coined, chamfered strip and is fabricated by line welding along intersection line, 5. Westinghouse spacer grid with split vane (Plus-7). The pressure loss coefficient of the Plain, Hybrid, Hybrid-SC, Hybrid-LC, and Plus-7 spacer grid is 0.93, 1.15, 1.02, 1.04, and 1.08, respectively.

  13. Influence of blockage effect on measurement by vane anemometers

    Directory of Open Access Journals (Sweden)

    Sluse Jan

    2017-01-01

    Full Text Available The article deals with influence of blockage effect caused by vane anemometer in the wind tunnel by measurement via this anemometer. The influences will be represented by correction coefficient. The first part of this article is focused on the design of the impeller of vane anemometers. The impellers are printed on 3D printer with variable parameters. The anemometer is fixed in an open section of the wind tunnel with closed loop and the velocity profile is measured by Laser Doppler velocimetry (LDV in front and behind it for all impellers. The experimental data are compared with the numerical simulation in OpenFOAM. The results are correction coefficients.

  14. Numerical Analysis and Geometry Optimisation of Vertical Vane of Room Air-conditioner

    Directory of Open Access Journals (Sweden)

    Al-Obaidi Abdulkareem Sh. Mahdi

    2018-01-01

    Full Text Available Vertical vanes of room air-conditioners are used to control and direct cold air. This paper aims to study vertical vane as one of the parameters that affect the efficiency of dissipating cold air to a given space. The vertical vane geometry is analysed and optimised for lower production cost using CFD. The optimised geometry of the vertical vane should have the same or increased efficiency of dissipating cold air and have lesser mass compared to the existing original design. The existing original design of vertical vane is simplified and analysed by using ANSYS Fluent. Efficiency of wind direction is define as how accurate the direction of airflow coming out from vertical vane. In order to calculate the efficiency of wind direction, 15° and 30° rotation of vertical vane inside room air-conditioner are simulated. The efficiency of wind direction for 15° rotation of vertical vane is 57.81% while efficiency of wind direction for 30° rotation of vertical vane is 47.54%. The results of the efficiency of wind direction are used as base reference for parametric study. The parameters investigated for optimisation of vertical vane are focused at length of long span, tip chord and short span. The design of 15% decreased in vane surface area at tip chord is the best optimised design of vertical vane because the efficiency of wind direction is the highest as 60.32%.

  15. Rod cluster having improved vane configuration

    International Nuclear Information System (INIS)

    Shockling, L.A.; Francis, T.A.

    1989-01-01

    This patent describes a pressurized water reactor vessel, the vessel defining a predetermined axial direction of the flow of coolant therewithin and having plural spider assemblies supporting, for vertical movement within the vessel, respective clusters of rods in spaced, parallel axial relationship, parallel to the predetermined axial direction of coolant flow, and a rod guide for each spider assembly and respective cluster of rods. The rod guide having horizontally oriented support plates therewithin, each plate having an interior opening for accommodating axial movement therethrough of the spider assembly and respective cluster of rods. The opening defining plural radially extending channels and corresponding parallel interior wall surfaces of the support plate

  16. Measuring Undrained Shear Strength using CPT and Field Vane

    DEFF Research Database (Denmark)

    Luke, Kirsten

    1992-01-01

    This paper presents the results of CPT's and Field Vane tests from two small test areas with different soils, Glacial Till and Yoldia Clay. An average of Nk = qt/cv for the Yoldia Clay is 7.7 with a standard deviation of 0.7. The average of Nk for the Glacial Till is 9.7 with a standard deviation...

  17. Intelligent electrical outlet for collective load control

    Science.gov (United States)

    Lentine, Anthony L.; Ford, Justin R.; Spires, Shannon V.; Goldsmith, Steven Y.

    2015-10-27

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and a supply of generated electric power in the microgrid at a given time.

  18. Socioeconomic determinants of exposure to alcohol outlets.

    Science.gov (United States)

    Morrison, Christopher; Gruenewald, Paul J; Ponicki, William R

    2015-05-01

    Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world.

  19. CFD analysis for spacer grid mixing vane design

    International Nuclear Information System (INIS)

    Park, Sung-Kew; Kim, Kang-Hoon; Park, Eung-Jun; Jung, Yil-Sup; Suh, Jung-Min; Jeong, Ji-Hun

    2008-01-01

    A computational fluid dynamics (CFD) analysis for a rod bundle with the larger scale model (6x6 array model) has been performed to develop the base shape of mixing vane in accordance with the hydraulic and thermal performance. Explanatory parameters are span pressure drop and span average heat transfer coefficient. The concern related to hot spot is also considered as a subsidiary criterion. Of the several candidates, the final candidate was determined by using the CFD analysis code, STAR-CD. And then, the optimization for it was performed using the response surface method (RSM) that the proper tolerance was considered under the two acceptance criteria such as lower span pressure drop while maintaining the span average heat transfer coefficient with respect to the current shape. The optimized mixing vane shape was verified by the CFD analysis including the effects of allowable tolerance. (author)

  20. Using public health and community partnerships to reduce density of alcohol outlets.

    Science.gov (United States)

    Jernigan, David H; Sparks, Michael; Yang, Evelyn; Schwartz, Randy

    2013-04-11

    Excessive alcohol use causes approximately 80,000 deaths in the United States each year. The Guide to Community Preventive Services recommends reducing the density of alcohol outlets - the number of physical locations in which alcoholic beverages are available for purchase either per area or per population - through the use of regulatory authority as an effective strategy for reducing excessive alcohol consumption and related harms. We briefly review the research on density of alcohol outlets and public health and describe the powers localities have to influence alcohol outlet density. We summarize Regulating Alcohol Outlet Density: An Action Guide, which describes steps that local communities can take to reduce outlet density and the key competencies and resources of state and local health departments. These include expertise in public health surveillance and evaluation methods, identification and tracking of outcome measures, geographic information systems (GIS) mapping, community planning and development of multisector efforts, and education of community leaders and policy makers. We illustrate the potential for partnerships between public health agencies and local communities by presenting a contemporary case study from Omaha, Nebraska. Public health agencies have a vital and necessary role to play in efforts to reduce alcohol outlet density. They are often unaware of the potential of this strategy and have strong potential partners in the thousands of community coalitions nationwide that are focused on reducing alcohol-related problems.

  1. A three dimensional model of a vane rheometer

    International Nuclear Information System (INIS)

    Nazari, Behzad; Moghaddam, Ramin Heidari; Bousfield, Douglas

    2013-01-01

    Highlights: • FEM was used to calculate the isothermal flow parameters in a vane geometry. • Velocity, pressure and then stress fields were obtained. • Using total stress, shaft torque was calculated to compare with experimental data. • A modified cell Reynolds number and power number were used to study flow pattern. • A comparison between 2D and 3D modeling was done based on calculated torques. -- Abstract: Vane type geometries are often used in rheometers to avoid slippage between the sample and the fixtures. While yield stress and other rheological properties can be obtained with this geometry, a complete analysis of this complex flow field is lacking in the literature. In this work, a finite element method is used to calculate the isothermal flow parameters in a vane geometry. The method solves the mass and momentum continuity equations to obtain velocity, pressure and then stress fields. Using the total stress numerical data, we calculated the torque applied on solid surfaces. The validity of the computational model was established by comparing the results to experimental results of shaft torque at different angular velocities. The conditions where inertial terms become important and the linear relationship between torque and stress are quantified with dimensionless groups. The accuracy of a two dimensional analysis is compared to the three dimensional results

  2. Experimental Study on Series Operation of Sliding Vane Pump and Centrifugal Pump

    OpenAIRE

    Li, Tao; Zhang, Weiming; Jiang, Ming; Li, Zhengyang

    2013-01-01

    A platform for sliding vane pump and centrifugal pump tests is installed to study the series operation of them under different characteristics of pipeline. Firstly, the sliding vane pump and the centrifugal pump work independently, and the performance is recorded. Then, the two types of pumps are combined together, with the sliding vane pump acting as the feeding pump. Comparison is made between the performance of the independently working pump and the performance of series operation pump. Re...

  3. Numerical Analysis of a Centrifugal Fan for Improved Performance using Splitter Vanes

    OpenAIRE

    N. Yagnesh Sharma; K. Vasudeva Karanth

    2009-01-01

    The flow field in a centrifugal fan is highly complex with flow reversal taking place on the suction side of impeller and diffuser vanes. Generally performance of the centrifugal fan could be enhanced by judiciously introducing splitter vanes so as to improve the diffusion process. An extensive numerical whole field analysis on the effect of splitter vanes placed in discrete regions of suspected separation points is possible using CFD. This paper examines the effect of sp...

  4. Water table tests of proposed heat transfer tunnels for small turbine vanes

    Science.gov (United States)

    Meitner, P. L.

    1974-01-01

    Water-table flow tests were conducted for proposed heat-transfer tunnels which were designed to provide uniform flow into their respective test sections of a single core engine turbine vane and a full annular ring of helicopter turbine vanes. Water-table tests were also performed for the single-vane test section of the core engine tunnel. The flow in the heat-transfer tunnels was shown to be acceptable.

  5. Theoretical morphology and development of flight feather vane asymmetry with experimental tests in parrots.

    Science.gov (United States)

    Feo, Teresa J; Prum, Richard O

    2014-06-01

    Asymmetry in flight feather vane width is a major functional innovation associated with the evolution of flight in the ancestors of birds. However, the developmental and morphological basis of feather shape is not simple, and the developmental processes involved in vane width asymmetry are poorly understood. We present a theoretical model of feather morphology and development that describes the possible ways to modify feather development and produce vane asymmetry. Our model finds that the theoretical morphospace of feather shape is redundant, and that many different combinations of parameters could be responsible for vane asymmetry in a given feather. Next, we empirically measured morphological and developmental model parameters in asymmetric and symmetric feathers from two species of parrots to identify which combinations of parameters create vane asymmetry in real feathers. We found that both longer barbs, and larger barb angles in the relatively wider trailing vane drove asymmetry in tail feathers. Developmentally, longer barbs were the result of an offset of the radial position of the new barb locus, whereas larger barb angles were produced by differential expansion of barbs as the feather unfurls from the tubular feather germ. In contrast, the helical angle of barb ridge development did not contribute to vane asymmetry and could be indicative of a constraint. This research provides the first comprehensive description of both the morphological and developmental modifications responsible for vane asymmetry within real feathers, and identifies key steps that must have occurred during the evolution of vane asymmetry. © 2014 Wiley Periodicals, Inc.

  6. Numerical analysis and experiment research on fluid orbital performance of vane type propellant management device

    International Nuclear Information System (INIS)

    Hu, Q; Li, Y; Pan, H L; Liu, J T; Zhuang, B T

    2015-01-01

    Vane type propellant management device (PMD) is one of the key components of the vane-type surface tension tank (STT), and its fluid orbital performance directly determines the STT's success or failure. In present paper, numerical analysis and microgravity experiment study on fluid orbital performance of a vane type PMD were carried out. By using two-phase flow model of volume of fluid (VOF), fluid flow characteristics in the tank with the vane type PMD were numerically calculated, and the rules of fluid transfer and distribution were gotten. A abbreviate model test system of the vane type PMD is established and microgravity drop tower tests were performed, then fluid management and transmission rules of the vane type PMD were obtained under microgravity environment. The analysis and tests results show that the vane type PMD has good and initiative fluid orbital management ability and meets the demands of fluid orbital extrusion in the vane type STT. The results offer valuable guidance for the design and optimization of the new generation of vane type PMD, and also provide a new approach for fluid management and control in space environment

  7. Experimental hot-wire measurements in a centrifugal compressor with vaned diffuser

    International Nuclear Information System (INIS)

    Pinarbasi, Ali

    2008-01-01

    The purpose of this study was to improve the understanding of the flow physics in a centrifugal compressor with vaned diffuser. For this reason three component hot wire measurements in the vaneless space and vane region of a low speed centrifugal compressor are presented. A low speed compressor with a 19 bladed backswept impeller and diffuser with 16 wedge vanes were used. The measurements were made at three inter-vane positions and are presented as mean velocity, turbulent kinetic energy and flow angle distributions. The flow entering the diffuser closely resembles the classic jet-wake flow characteristic of centrifugal impeller discharges. A strong upstream influence of the diffuser vanes is observed which results in significant variations in flow quantities between the vane-to-vane locations. The circumferential variations due to the passage and blade wakes rapidly mix out in the vaneless space, although some variations are still discernible in the vaned region. The impeller blade wakes mix out rapidly within the vaneless space and more rapidly than in an equivalent vaneless diffuser. Although the flow is highly non uniform in velocity at the impeller exit, there is no evidence in the results of any separation from the diffuser vanes

  8. Socioeconomic Determinants of Exposure to Alcohol Outlets

    Science.gov (United States)

    Morrison, Christopher; Gruenewald, Paul J.; Ponicki, William R.

    2015-01-01

    Objective: Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Method: Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Results: Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. Conclusions: These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world. PMID:25978830

  9. Alcohol outlets, social disorganization, and robberies: accounting for neighborhood characteristics and alcohol outlet types.

    Science.gov (United States)

    Snowden, Aleksandra J; Freiburger, Tina L

    2015-05-01

    We estimated spatially lagged regression and spatial regime models to determine if the variation in total, on-premise, and off-premise alcohol outlet(1) density is related to robbery density, while controlling for direct and moderating effects of social disorganization.(2) Results suggest that the relationship between alcohol outlet density and robbery density is sensitive to the measurement of social disorganization levels. Total alcohol outlet density and off-premise alcohol outlet density were significantly associated with robbery density when social disorganization variables were included separately in the models. However, when social disorganization levels were captured as a four item index, only the association between off-premise alcohol outlets and robbery density remained significant. More work is warranted in identifying the role of off-premise alcohol outlets and their characteristics in robbery incidents. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. MRI of thoracic outlet syndrome in children

    Energy Technology Data Exchange (ETDEWEB)

    Chavhan, Govind B.; Batmanabane, Vaishnavi [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto, ON (Canada); Muthusami, Prakash [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto, ON (Canada); The Hospital for Sick Children, Division of Image Guided Therapy, Department of Diagnostic Imaging, Toronto, ON (Canada); Towbin, Alexander J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology and Medical Imaging, Cincinnati, OH (United States); Borschel, Gregory H. [The Hospital for Sick Children and University of Toronto, Division of Plastic Surgery, Department of Pediatric Surgery, Toronto, ON (Canada)

    2017-09-15

    Thoracic outlet syndrome is caused by compression of the neurovascular bundle as it passes from the upper thorax to the axilla. The neurovascular bundle can be compressed by bony structures such as the first rib, cervical ribs or bone tubercles, or from soft-tissue abnormalities like a fibrous band, muscle hypertrophy or space-occupying lesion. Thoracic outlet syndrome commonly affects young adults but can be seen in the pediatric age group, especially in older children. Diagnosis is based on a holistic approach encompassing clinical features, physical examination findings including those triggered by various maneuvers, electromyography, nerve conduction studies and imaging. Imaging is performed to confirm the diagnosis, exclude mimics and classify thoracic outlet syndrome into neurogenic, arterial, venous or mixed causes. MRI and MR angiography are useful in this process. A complete MRI examination for suspected thoracic outlet syndrome should include the assessment of anatomy and any abnormalities using routine sequences, vessel assessment with the arms in adduction by MR angiography and assessment of dynamic compression of vessels with abduction of the arms. The purpose of this paper is to describe the anatomy of the thoracic outlet, causes of thoracic outlet syndrome, the MR imaging techniques used in its diagnosis and the principles of image interpretation. (orig.)

  11. MRI of thoracic outlet syndrome in children

    International Nuclear Information System (INIS)

    Chavhan, Govind B.; Batmanabane, Vaishnavi; Muthusami, Prakash; Towbin, Alexander J.; Borschel, Gregory H.

    2017-01-01

    Thoracic outlet syndrome is caused by compression of the neurovascular bundle as it passes from the upper thorax to the axilla. The neurovascular bundle can be compressed by bony structures such as the first rib, cervical ribs or bone tubercles, or from soft-tissue abnormalities like a fibrous band, muscle hypertrophy or space-occupying lesion. Thoracic outlet syndrome commonly affects young adults but can be seen in the pediatric age group, especially in older children. Diagnosis is based on a holistic approach encompassing clinical features, physical examination findings including those triggered by various maneuvers, electromyography, nerve conduction studies and imaging. Imaging is performed to confirm the diagnosis, exclude mimics and classify thoracic outlet syndrome into neurogenic, arterial, venous or mixed causes. MRI and MR angiography are useful in this process. A complete MRI examination for suspected thoracic outlet syndrome should include the assessment of anatomy and any abnormalities using routine sequences, vessel assessment with the arms in adduction by MR angiography and assessment of dynamic compression of vessels with abduction of the arms. The purpose of this paper is to describe the anatomy of the thoracic outlet, causes of thoracic outlet syndrome, the MR imaging techniques used in its diagnosis and the principles of image interpretation. (orig.)

  12. The prospects of making small retail outlets in the Townships aggressively competitive

    Directory of Open Access Journals (Sweden)

    Malefane Johannes Lebusa

    2013-12-01

    Full Text Available Historically, township Small Retail Outlets were mostly established for survival and operated under a generally closed market system where the competition was not very strong. However, with the advent of democracy many people lost their formal income through retrenchments and out of desperation, many of these people opened Small Retail Outlets thus most of the existing and new entrants into the township market were unskilled or semiskilled labourers with little or no formal skills in business or entrepreneurship. Such efforts were rarely guided by any specific and informed strategy of identifying and exploiting a gap in the market. With the consolidation of the free market system under democracy, big brand businesses such as Shoprite Checkers and Small Retail Outlets of foreign nationals with different strategies entered and competed in this township market. With fewer formal skills in business and entrepreneurship, the owners of the Small Retail Outlets struggled to compete and thrive under these relatively new economic conditions. Given this situation, I conducted semi-structured interviews with fifteen of these traditional Small Retail Outlets to find out and better understand the challenges they face and the skills that might be needed to aggressively compete in this space. Based on these findings and understandings, I further examined these issues and suggest infusions of specific entrepreneurship skills that could develop their aggressive competitiveness. Keywords: entrepreneurship, competitiveness, small retail outlets, shopping complexes, innovation

  13. The Screw-Conveyor Vane Design for Piece-Wise Construction ...

    African Journals Online (AJOL)

    Such a method of manufacture is beyond the resources of a general-purpose metal workshop that may require the odd spiral vane once in a while and can neither afford the time nor the cost of ordering from abroad. In this article the method of six blanks which the author has developed for the building up of the vane ...

  14. 14 CFR 23.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 23.977 Section 23.977... tank outlet. (a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This... damage any fuel system component. (b) The clear area of each fuel tank outlet strainer must be at least...

  15. Study and Control of a Radial Vaned Diffuser Stall

    Directory of Open Access Journals (Sweden)

    Aurélien Marsan

    2012-01-01

    Full Text Available The aim of the present study is to evaluate the efficiency of a boundary layer suction technique in case of a centrifugal compressor stage in order to extend its stable operating range. First, an analysis of the flow pattern within the radial vaned diffuser is presented. It highlights the stall of the diffuser vanes when reaching a low massflow. A boundary layer separation in the hub-suction side corner grows when decreasing the massflow from the nominal operating point to the surge and finally leads to a massive stall. An aspiration strategy is investigated in order to control the stall. The suction slot is put in the vicinity of the saddle that originates the main separating skin-friction line, identified thanks to the analysis of the skin-friction pattern. Several aspiration massflow rates are tested, and two different modelings of the aspiration are evaluated. Finally, an efficient control is reached with a removal of only 0,1% of the global massflow and leads—from a steady-state calculations point of view—to an increase by 40% of the compressor operating range extent.

  16. Computational Fluid Dynamics (CFD) Analyses in Support of Space Shuttle Main Engine (SSME) Heat Exchanger (HX) Vane Cracking Investigation

    Science.gov (United States)

    Garcia, Roberto; Benjamin, Theodore G.; Cornelison, J.; Fredmonski, A. J.

    1993-01-01

    Integration issues involved with installing the alternate turbopump (ATP) High Pressure Oxygen Turbopump (HPOTP) into the SSME have raised questions regarding the flow in the HPOTP turnaround duct (TAD). Steady-state Navier-Stokes CFD analyses have been performed by NASA and Pratt & Whitney (P&W) to address these questions. The analyses have consisted of two-dimensional axisymmetric calculations done at Marshall Space Flight Center and three-dimensional calculations performed at P&W. These analyses have identified flowfield differences between the baseline ATP and the Rocketdyne configurations. The results show that the baseline ATP configuration represents a more severe environment to the inner HX guide vane. This vane has limited life when tested in conjunction with the ATP but infinite life when tested with the current SSME HPOTP. The CFD results have helped interpret test results and have been used to assess proposed redesigns. This paper includes details of the axisymmetric model, its results, and its contribution towards resolving the problem.

  17. Complot test section outlet CFD optimization (pre - test and dimensioning)

    International Nuclear Information System (INIS)

    Profir, M. M.; Moreau, V.; Kennedy, G.

    2013-01-01

    In the framework of the FP7 MAXSIMA European project, the COMPLOT (COMPonent LOop Testing) LBE experimental facility is employed for thermal-hydraulic experiments aimed to test and qualify, among other components, a buoyancy driven safety/control rods (SR/CR) system, as key components for the safe operation of the MYRRHA reactor. This paper focuses mainly on a simplified CFD representation of the SR test section outlet in order to optimise it for the testing program. Parametric cases, associated with different positions of the SR assembly have been set up and analysed. A quasi-static analysis has been performed for each case, accounting for the LBE volume displaced by the insertion of the SR bundle, by introducing appropriately positioned additional mass sources. Velocity and pressure fields, as well as pressure drop magnitudes and mass flow rates through relevant guide tube hole outlets have been calculated and compared. The CFD analysis proved that the outer boundary of the test section does not impact the expected performance of the SR (rapid transient downward insertion). Preliminary simulations reproducing the timely repositioning of the SR/CR in COMPLOT using procedures of automatic volume mesh regeneration, consistently with the rod imposed displacement, are illustrated. (authors)

  18. Hot spot detection system for vanes or blades of a combustion turbine

    Science.gov (United States)

    Twerdochlib, M.

    1999-02-02

    This invention includes a detection system that can determine if a turbine component, such as a turbine vane or blade, has exceeded a critical temperature, such as a melting point, along any point along the entire surface of the vane or blade. This system can be employed in a conventional combustion turbine having a compressor, a combustor and a turbine section. Included within this system is a chemical coating disposed along the entire interior surface of a vane or blade and a closed loop cooling system that circulates a coolant through the interior of the vane or blade. If the temperature of the vane or blade exceeds a critical temperature, the chemical coating will be expelled from the vane or blade into the coolant. Since while traversing the closed loop cooling system the coolant passes through a detector, the presence of the chemical coating in the coolant will be sensed by the system. If the chemical coating is detected, this indicates that the vane or blade has exceeded a critical temperature. 5 figs.

  19. Double-outlet right ventricle revisited.

    Science.gov (United States)

    Ebadi, Ameneh; Spicer, Diane E; Backer, Carl L; Fricker, F Jay; Anderson, Robert H

    2017-08-01

    Double-outlet right ventricle is a form of ventriculoarterial connection. The definition formulated by the International Society for Nomenclature of Paediatric and Congenital Heart Disease is based on hearts with both arterial trunks supported in their greater part by a morphologically right ventricle. Bilateral infundibula and ventricular septal defects are highly debated criteria. This study examines the anatomic controversies surrounding double-outlet right ventricle. We show that hearts with double-outlet right ventricle can have atrioventricular-to-arterial valvular continuity. We emphasize the difference between the interventricular communication and the zone of deficient ventricular septation. The hearts examined were from the University of Florida in Gainesville; Johns Hopkins All Children's Hospital, St Petersburg, Fla; and Lurie Children's Hospital, Chicago, Ill. Each specimen had at least 75% of both arterial roots supported by the morphologically right ventricle, with a total of 100 hearts examined. The morphologic method was used to assess anatomic features, including arterial-atrioventricular valvular continuity, subarterial infundibular musculature, and the location of the hole between the ventricles. Most hearts had fibrous continuity between one of the arterial valves and an atrioventricular valve, with bilateral infundibula in 23%, and intact ventricular septum in 5%. Bilateral infundibula are not a defining feature of double-outlet right ventricle, representing only 23% of the specimens in our sample. The interventricular communication can have a posteroinferior muscular rim or extend to become perimembranous (58%). Double-outlet right ventricle can exist with an intact ventricular septum. Copyright © 2017 The American Association for Thoracic Surgery. All rights reserved.

  20. A niche marketing guide for lamb cooperatives

    OpenAIRE

    Kazmierczak, Tamra Kirkpatrick; Bell, James B.

    1995-01-01

    The two types of niche markets targeted by lamb marketing cooperatives are described in this guide. The first type includes specialty middlemen outlets that cooperatives used to market lamb to specialized niches within the traditional meat marketing system of retail food stores, restaurants, food service outlets, and specialty distributors. The second type includes those outlets that cooperatives used to market lamb directly to the consumer, such as freezer markets, farmers' markets, mobile m...

  1. Turbine blade and vane heat flux sensor development, phase 2

    Science.gov (United States)

    Atkinson, W. H.; Cyr, M. A.; Strange, R. R.

    1985-01-01

    The development of heat flux sensors for gas turbine blades and vanes and the demonstration of heat transfer measurement methods are reported. The performance of the heat flux sensors was evaluated in a cylinder in cross flow experiment and compared with two other heat flux measurement methods, the slug calorimeter and a dynamic method based on fluctuating gas and surface temperature. Two cylinders, each instrumented with an embedded thermocouple sensor, a Gardon gauge, and a slug calorimeter, were fabricated. Each sensor type was calibrated using a quartz lamp bank facility. The instrumented cylinders were then tested in an atmospheric pressure combustor rig at conditions up to gas stream temperatures of 1700K and velocities to Mach 0.74. The test data are compared to other measurements and analytical prediction.

  2. LOX/LH2 vane pump for auxiliary propulsion systems

    Science.gov (United States)

    Hemminger, J. A.; Ulbricht, T. E.

    1985-01-01

    Positive displacement pumps offer potential efficiency advantages over centrifugal pumps for future low thrust space missions. Low flow rate applications, such as space station auxiliary propulsion or dedicated low thrust orbiter transfer vehicles, are typical of missions where low flow and high head rise challenge centrifugal pumps. The positive displacement vane pump for pumping of LOX and LH2 is investigated. This effort has included: (1) a testing program in which pump performance was investigated for differing pump clearances and for differing pump materials while pumping LN2, LOX, and LH2; and (2) an analysis effort, in which a comprehensive pump performance analysis computer code was developed and exercised. An overview of the theoretical framework of the performance analysis computer code is presented, along with a summary of analysis results. Experimental results are presented for pump operating in liquid nitrogen. Included are data on the effects on pump performance of pump clearance, speed, and pressure rise. Pump suction performance is also presented.

  3. On development of RFQ vanes from beam dynamics data

    International Nuclear Information System (INIS)

    Chatterjee, Avik; Padhi, Rakesh; Banerjee, M.K.; Naik, Vaishali; Sanyal, Dirtha; Choudhury, Siddhartha De; Chakrabarti, Alok

    2005-01-01

    Simulation at critical steps of product development greatly helps to detect the design flaws at the earlier stage and gives a digital platform to iterate the design and process at the initial stage. This helps to reduce the risk of failure considerably and gives an alternative to reduce the number of physical prototypes for design validation. Modern concepts of virtual prototyping for predicting functional behaviour of a product and process are gaining momentum globally as it is the fully integrated approach to converge the concepts of functional design, Design for Manufacturing (DFM), Design for Assembly (DFA) and manufacturing process simulation. This concept has been partially implemented in development of RFQ (Radio Frequency Quadruple) vanes and the basic guidelines have been discussed. (author)

  4. Thermal modelling of a dry revolving vane compressor

    Science.gov (United States)

    Ooi, K. T.; Aw, K. T.

    2017-08-01

    The lubricant used in compressors serves to lubricate, to seal the gaps to reduce internal leakage and to a certain extent, to cool. However, a lubricant free compressor is attractive if lubricants become a source of contaminant, or in areas where the compressor needs be placed under any orientation, such as those in military or portable computing. In this paper, a thermal model for a dry revolving vane compressor is presented. This thermal model sets out to predict the steady-state operating temperatures of the compressor components. The lumped thermal conductance method was employed. The results of the components temperature will be presented and discussed. A high potential for overheating is observed at the shaft bearings.

  5. Testing of Composite Fan Vanes With Erosion-Resistant Coating Accelerated

    Science.gov (United States)

    Bowman, Cheryl L.; Sutter, James K.; Otten, Kim D.; Samorezov, Sergey; Perusek, Gail P.

    2004-01-01

    The high-cycle fatigue of composite stator vanes provided an accelerated life-state prior to insertion in a test stand engine. The accelerated testing was performed in the Structural Dynamics Laboratory at the NASA Glenn Research Center under the guidance of Structural Mechanics and Dynamics Branch personnel. Previous research on fixturing and test procedures developed at Glenn determined that engine vibratory conditions could be simulated for polymer matrix composite vanes by using the excitation of a combined slip table and electrodynamic shaker in Glenn's Structural Dynamics Laboratory. Bench-top testing gave researchers the confidence to test the coated vanes in a full-scale engine test.

  6. Vane fabrication for the proof-of-principle radio-frequency quadrupole accelerator

    International Nuclear Information System (INIS)

    Williams, S.W.; Potter, J.M.

    1981-01-01

    The electrodes for the Proof-of-Principle (POP) Radio-Frequency Quadrupole (RFQ) accelerator were machined on a numerically controlled, three-axis, vertical mill. These pole tips, or vanes, were prepared for, and used, in the successful demonstration of RFQ practicality at Los Alamos National Laboratory in February 1980. The data set that described the vanes contained about 10 million bits of tool position data. The vanes were cut from OFHC copper blanks. The tolerances achieved were approximately +- 0.005 cm. The design and manufacturing procedures are described

  7. Powerful Swirl Generation of Flow-driven Rotating Mixing Vane for Enhancing CHF

    International Nuclear Information System (INIS)

    Seo, Han; Seo, Seok Bin; Heo, Hyo; Bang, In Cheol

    2014-01-01

    Mixing vanes are utilized to improve CHF and heat transfer performance in the rod bundle during normal operation. Experimental measurement of the swirling flow from a split vane pair was conducted using particle image velocimetry (PIV) and boroscope. The lateral velocity fields show that the swirling flow was initially centered in the subchannel and the computational fluid dynamics (CFD) analysis was performed based on the experiment. To visualize flow patterns in the 5Χ5 subchannel using PIV, matching the refraction between the working fluid and the structure was considered and the experiment aimed to develop the experimental data for providing fundamental information of the CFD analysis. The fixed split vane is the main mixing inducer in the fuel assembly. In a heat exchanger research, propeller type swirl generates at several pitch ratios and different blades angles were used to enhance heat transfer rate. Significant improvements of the heat transfer rate using the propellers were confirmed due to creation of tangential flow. In the present study, the mixing effect of rotation vane which has a shape of propeller was studied using PIV. A split vane was considered in the experiment to show the effect of rotation vane. Vertical and horizontal flow analyses were conducted to show the possible use of rotation vane in a subchannel. In the present work, the study of flow visualization using three types of vanes is conducted to show the mixing effect. The vertical flow and the horizontal flow distributions were analyzed in the two experimental facilities. For the vertical flow facility, flow distributions, flow profiles, and the turbulence kinetic energy are analyzed at the centerline of the channel. The results show that the rotation vane has the highest flow and turbulence kinetic intensity at the centerline of the channel. For the horizontal flow facility, the results indicate that lateral flow of the rotation vane is generated and maintained along with the flow

  8. Approach to the HTGR core outlet temperature measurements in the United States

    International Nuclear Information System (INIS)

    Franklin, R.; Rodriguez, C.

    1982-06-01

    The High Temperature Gas-Cooled Reactor (HTGR) constructed at Fort St. Vrain Colorado (330 MWe) used Geminol thermocouples to measure the primary coolant temperature at the core outlet. The primary coolant (helium) is heated by the graphite core to temperatures in the range of 700 deg. to 750 deg. C. The combination of the high temperature, high flow rate and radiation at the core outlet area makes it difficult to obtain accurate temperature measurements. The Geminol thermocouples installed in the Fort St. Vrain reactor have provided accurate data for several years of power operation without any failures. The indicated temperature of the core outlet thermocouples agrees with a ''traversing'' thermocouple measurement to within +-2 deg. C. The Geminol thermocouple wire was provided by the Driver-Harris Company and is similar to the chromel versus alumel thermocouple. Geminol wire is no longer distributed and on future designs, chromel versus alumel wire will be used. The next large HTGR design, which is being performed with funding support from the United States Department of Energy, will incorporate replaceable thermocouples. The thermocouples used in the Fort St. Vrain reactor were permanently installed and large in diameter (6.35 mm) to insure good reliability. The replaceable thermocouples to be used in the next large reactor will be smaller in diameter (3.18 mm). These replaceable thermocouples will be inserted into the core outlet area through long curved guide tubes that are permanently installed. These guide tubes are as long as 18 meters and must be curved to reach the core outlet regions. Tests were conducted to prove that the thermocouples could be inserted and removed through the long curved guide tubes. (author)

  9. 49 CFR 178.345-11 - Tank outlets.

    Science.gov (United States)

    2010-10-01

    ... unloading of lading, as distinguished from outlets such as manhole covers, vents, vapor recovery devices... away from the loading/unloading outlet. The actuating mechanism must be corrosion-resistant and...

  10. Hydrologic Outlets of the Greenland Ice Sheet, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hydrologic Outlets of the Greenland Ice Sheet data set contains GIS point shapefiles that include 891 observed and potential hydrologic outlets of the Greenland...

  11. Suction Side Roughness Effects on Film Cooling Heat Transfer on a Turbine Vane

    National Research Council Canada - National Science Library

    Rutledge, James

    2004-01-01

    An experimental study was conducted in a simulated three vane linear cascade to determine the effects of surface roughness and film cooling on the heat transfer coefficient distribution in the region...

  12. Power source with spark-safe outlet

    Energy Technology Data Exchange (ETDEWEB)

    Tsesarenko, N P; Alekhin, A V

    1982-01-01

    The invention refers to the technique of electrical monitoring and control in systems operating in a spark-safe medium (for example, in coal mines). A more accurate area of application is mobile objects with autonomous source of electricity (mine diesel locomotives, battery electric locomotives etc.). The purpose of the invention is to simplify and to improve the reliability of the planned device, and also to expand the area of application for conditions when it is powered from an autonomous generator of direct voltage. This goal is achieved because the power source with spark-safe outlet (the source contains a thyristor of advance disconnection, connected by anode to the delimiting throttle, one outlet of which is connected to the capacitor included between the controlling electrode and the anode of the thyristor, and the capacitor is connected through the resistor parallel to the outlet clamps of the source, while the thyristor of emergency protection connected parallel to the inlet clamps of the power source) is additionally equipped with a current sensor, hercon, transistor key (included in series in the power circuit) and optron, whose emitter is connected parallel to the current sensor connected in series to the inlet of the power source, while the receiver of the optron is connected in a circuit for controlling the thyristor of emergency protection. Hercon is built into the core of the delimiting throttle and is connected to the circuit for controlling the transistor key.

  13. Further development and performance evaluation of the autonomous sailing boat Maribot Vane

    OpenAIRE

    Dhomé, Ulysse

    2018-01-01

    This paper describes the ongoing development of Maribot Vane, an autonomous sailing vessel at the Maritime Robotics Laboratory of KTH, the Royal Institute of Technology, Stockholm. There is an ac-celerating need for ocean sensing where autonomous vehicles can play a key role in assisting scientists with environmental monitoring and collecting oceanographic data. The purpose of Maribot Vane is to offer a sus-tainable alternative for these autonomous missions by using wind and an energy efficie...

  14. Analysis of the Sales Promotion in Choice Retail Outlet

    OpenAIRE

    HUMPOLCOVÁ, Michaela

    2010-01-01

    My bachelor thesis is aimed at sales promotion in a retail outlet. The main aim of this thesis is evaluate the current state of sales promotion in a selected retail outlet and based on the analysis of the current state of sales promotion in the outlet to try to propose some measures of improve.

  15. 14 CFR 25.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 25.977 Section 25.977... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.977 Fuel tank outlet. (a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This strainer must— (1) For...

  16. 14 CFR 29.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 29.977 Section 29.977... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.977 Fuel tank outlet. (a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This strainer must— (1) For...

  17. 14 CFR 27.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 27.977 Section 27.977... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.977 Fuel tank outlet. (a) There must be a fuel stainer for the fuel tank outlet or for the booster pump. This strainer must— (1) For...

  18. Alcohol Outlet Density and Intimate Partner Violence in a Nonmetropolitan College Town: Accounting for Neighborhood Characteristics and Alcohol Outlet Types.

    Science.gov (United States)

    Snowden, Aleksandra J

    2016-01-01

    There is a growing evidence of an ecological association between alcohol outlet density and intimate partner violence. It is reasonable to assume, however, that not all types of alcohol outlets contribute equally to criminal behavior, and to date, most ecological studies have been of large urban cities. Using Bloomington, Indiana, block groups as units of analysis and controlling for several structural characteristics associated with violence rates, I estimated spatially lagged regression models to determine if the variation in alcohol outlet density, including total outlets and disaggregating by on- and off-premise outlets, is related to intimate partner violence density. Results suggested that total alcohol outlet density and off-premise alcohol outlet density were significantly associated with intimate partner violence density. On-premise alcohol outlet density was not significantly associated with intimate partner violence density. These results not only extend the geographic scope of this relationship beyond large metropolitan areas but also have important policy implications.

  19. Numerical modelling of multi-vane expander operating conditions in ORC system

    Science.gov (United States)

    Rak, Józef; Błasiak, Przemysław; Kolasiński, Piotr

    2017-11-01

    Multi-vane expanders are positive displacement volumetric machines which are nowadays considered for application in micro-power domestic ORC systems as promising alternative to micro turbines and other volumetric expanders. The multi-vane expander features very simple design, low gas flow capacity, low expansion ratios, an advantageous ratio of the power output to the external dimensions and are insensitive to the negative influence of the gas-liquid mixture expansion. Moreover, the multi-vane expander can be easily hermetically sealed, which is one of the key issues in the ORC system design. A literature review indicates that issues concerning the application of multi-vane expanders in such systems, especially related to operating of multi-vane expander with different low-boiling working fluids, are innovative, not fully scientifically described and have the potential for practical implementation. In this paper the results of numerical investigations on multi-vane expander operating conditions are presented. The analyses were performed on three-dimensional numerical model of the expander in ANSYS CFX software. The numerical model of the expander was validated using the data obtained from the experiment carried out on a lab test-stand. Then a series of computational analysis were performed using expanders' numerical model in order to determine its operating conditions under various flow conditions of different working fluids.

  20. Study on effects of mixing vane grids on coolant temperature distribution by subchannel analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mao, H.; Yang, B.W.; Han, B. [Xi' an Jiaotong Univ., Shaanxi (China). Science and Technology Center for Advanced Nuclear Fuel Research

    2016-07-15

    Mixing vane grids (MVG) have great influence on coolant temperature field in the rod bundle. The MVG could enhance convective heat transfer between the fuel rod wall and the coolant, and promote inter-subchannel mixing at the same time. For the influence of the MVG on convective heat transfer enhancement, many experiments have been done and several correlations have been developed based on the experimental data. However, inter-subchannel mixing promotion caused by the MVG is not well estimated in subchannel analysis because the information of mixing vanes is totally missing in most subchannel codes. This paper analyzes the influence of mixing vanes on coolant temperature distribution using the improved MVG model in subchannel analysis. The coolant temperature distributions with the MVG are analyzed, and the results show that mixing vanes lead to a more uniform temperature distribution. The performances of split vane grids under different power conditions are evaluated. The results are compared with those of spacer grids without mixing vanes and some conclusions are obtained.

  1. Numerical modelling of multi-vane expander operating conditions in ORC system

    Directory of Open Access Journals (Sweden)

    Rak Józef

    2017-01-01

    Full Text Available Multi-vane expanders are positive displacement volumetric machines which are nowadays considered for application in micro-power domestic ORC systems as promising alternative to micro turbines and other volumetric expanders. The multi-vane expander features very simple design, low gas flow capacity, low expansion ratios, an advantageous ratio of the power output to the external dimensions and are insensitive to the negative influence of the gas-liquid mixture expansion. Moreover, the multi-vane expander can be easily hermetically sealed, which is one of the key issues in the ORC system design. A literature review indicates that issues concerning the application of multi-vane expanders in such systems, especially related to operating of multi-vane expander with different low-boiling working fluids, are innovative, not fully scientifically described and have the potential for practical implementation. In this paper the results of numerical investigations on multi-vane expander operating conditions are presented. The analyses were performed on three-dimensional numerical model of the expander in ANSYS CFX software. The numerical model of the expander was validated using the data obtained from the experiment carried out on a lab test-stand. Then a series of computational analysis were performed using expanders' numerical model in order to determine its operating conditions under various flow conditions of different working fluids.

  2. Study on effects of mixing vane grids on coolant temperature distribution by subchannel analysis

    International Nuclear Information System (INIS)

    Mao, H.; Yang, B.W.; Han, B.

    2016-01-01

    Mixing vane grids (MVG) have great influence on coolant temperature field in the rod bundle. The MVG could enhance convective heat transfer between the fuel rod wall and the coolant, and promote inter-subchannel mixing at the same time. For the influence of the MVG on convective heat transfer enhancement, many experiments have been done and several correlations have been developed based on the experimental data. However, inter-subchannel mixing promotion caused by the MVG is not well estimated in subchannel analysis because the information of mixing vanes is totally missing in most subchannel codes. This paper analyzes the influence of mixing vanes on coolant temperature distribution using the improved MVG model in subchannel analysis. The coolant temperature distributions with the MVG are analyzed, and the results show that mixing vanes lead to a more uniform temperature distribution. The performances of split vane grids under different power conditions are evaluated. The results are compared with those of spacer grids without mixing vanes and some conclusions are obtained.

  3. Stratification in SNR-300 outlet plenum

    International Nuclear Information System (INIS)

    Reinders, R.

    1983-01-01

    In the inner outlet plenum of the SNR-300 under steady state conditions a large toroidal vortex is expected. The main flow passes through the gap between dipplate and shield vessel to the outer annular space. Only 3% of the flow pass the 24 emergency cooling holes, situated in the shield vessel. The sodium leaves the reactor tank through the 3 symmetrically arranged outlet nozzles. For a scram flow rates and temperatures are decreased simultaneously, so it is expected, that stratification occurs in the inner outlet plenum. A measure of stratification effects is the Archimedes Number Ar, which is the relation of buoyancy forces (negative) to kinetic energy. (The Archimedes Number is nearly identical with the Richardson Number). For values Ar>1 stratification can occur. Under the assumption of stratification the code TIRE was developed, which is only applicable for the period of time after some 50 sec after scram. This code serves for long term calculations. As the equations are very simple, it is a very fast code which gives the possibility to calculate transients for some hours real time. This code mainly has to take into account the pressure difference between inner plenum and outlet annulus caused by geodatic pressure. That force is in equilibrium with the pressure drop over the gap and holes in the shield vessel. For more detailed calculations of flow pattern and temperature distribution the code MIX and INKO 2T are applied. MIX was developed and validated at ANL, INKO 2T is a development of INTERATOM. INKO 2T is under validation. Mock up experiments were carried out with water to simulate the transient behavior of the SNR-300 outlet plenum. Calculations obtained by INKO 2T for steady state and the transient are shown for the flow pattern. Results of measurements also prove that stratification begins after about 30 sec. Measurements and detailed calculations show that it is admissible to use the code TIRE for the long term calculations. Calculations for a scram

  4. Exergy Analysis of the Revolving Vane Compressed Air Engine

    Directory of Open Access Journals (Sweden)

    Alison Subiantoro

    2016-01-01

    Full Text Available Exergy analysis was applied to a revolving vane compressed air engine. The engine had a swept volume of 30 cm3. At the benchmark conditions, the suction pressure was 8 bar, the discharge pressure was 1 bar, and the operating speed was 3,000 rev·min−1. It was found that the engine had a second-law efficiency of 29.6% at the benchmark conditions. The contributors of exergy loss were friction (49%, throttling (38%, heat transfer (12%, and fluid mixing (1%. A parametric study was also conducted. The parameters to be examined were suction reservoir pressure (4 to 12 bar, operating speed (2,400 to 3,600 rev·min−1, and rotational cylinder inertia (0.94 to 2.81 g·mm2. The study found that a higher suction reservoir pressure initially increased the second-law efficiency but then plateaued at about 30%. With a higher operating speed and a higher cylinder inertia, second-law efficiency decreased. As compared to suction pressure and operating speed, cylinder inertia is the most practical and significant to be modified.

  5. [Total pollution features of urban runoff outlet for urban river].

    Science.gov (United States)

    Luo, Hong-Bing; Luo, Lin; Huang, Gu; He, Qiang; Liu, Ping

    2009-11-01

    The urban stormwater runoff discharged to urban river, especially to rainfall source river, cannot be ignored. In this study, the Futian River watershed in Shenzhen city in a typical southern city of China is taken as the research object. In order to guide the pollution control for urban river, the eighteen rainfall events were monitored, and the total pollution features of the urban runoff outlet for this urban river were analyzed and discussed by using the process of pollutographs, the identifying to first flush, event mean concentration (EMC), etc. Results show that the concentrations of COD, SS, TN, TP and BOD5 are ten times more than the grade V of the environmental quality standards for surface water during the runoff time; the pollution caused by heavy metals (Cr, Ge, Cu, Hg and As) in runoff at a typical rainfall event is serious; the average and range of pollutant concentration at this runoff outlet in study area are evidently higher than at Shapingba in Chongqing city of China and at Silerwood in Canada, but are lower than at Shilipu in Wuhan city of China. The first flushes of COD, SS, BOD5, especially COD and SS, are evident, but the TN and TP are not. The average EMC of COD, TN, TP and BOD5 are 224.14, 571.15, 5.223, 2.04, 143.5 mg/L, respectively. To some extent, the EMC of COD is about two times of the value of the near cities, Macao and Zhuhai. The EMC of TN and TP are obviously higher than Beijing, Guangzhou and Shanghai. To compared with foreign counties, the EMC of the study area in Shenzhen is obviously much higher than the cities of Korean, USA and Canada. So the total pollution caused by the urban surface runoff in study area is serious and necessary to be treated.

  6. On the study of wavy leading-edge vanes to achieve low fan interaction noise

    Science.gov (United States)

    Tong, Fan; Qiao, Weiyang; Xu, Kunbo; Wang, Liangfeng; Chen, Weijie; Wang, Xunnian

    2018-04-01

    The application of wavy leading-edge vanes to reduce a single-stage axial fan noise is numerically studied. The aerodynamic and acoustic performance of the fan is numerically investigated using a hybrid unsteady Reynolds averaged Navier-Stokes (URANS)/acoustic analogy method (Goldstein equations). First, the hybrid URANS/Goldstein method is developed and successfully validated against experiment results. Next, numerical simulations are performed to investigate the noise reduction effects of the wavy leading-edge vanes. The aerodynamic and acoustic performance is assessed for a fan with vanes equipped with two different wavy leading-edge profiles and compared with the performance of conventional straight leading-edge vanes. Results indicate that a fan with wavy leading-edge vanes produces lower interaction noise than the baseline fan without a significant loss in aerodynamic performance. In fact, it is demonstrated that wavy leading-edge vanes have the potential to lead to both aerodynamic and acoustic improvements. The two different wavy leading-edge profiles are shown to successfully reduce the fan tone sound power level by 1.2 dB and 4.3 dB, respectively. Fan efficiency is also improved by about 1% with one of the tested wavy leading-edge profiles. Large eddy simulation (LES) is also performed for a simplified fan stage model to assess the effects of wavy leading-edge vanes on the broadband fan noise. Results indicate that the overall sound power level of a fan can be reduced by about 4 dB with the larger wavy leading-edge profile. Finally, the noise reduction mechanisms are investigated and analysed. It is found that the wavy leading-edge profiles can induce significant streamwise vorticity around the leading-edge protuberances and reduce pressure fluctuations (especially at locations of wavy leading-edge hills) and unsteady forces on the stator vanes. The underlying mechanism of the reduced pressure fluctuations is also discussed by examining the magnitude

  7. Test procedure for use of the shear vane in tanks 103-SY, 103-AN, and 103-AW

    International Nuclear Information System (INIS)

    LeClair, M.D.; Waters, E.

    1995-01-01

    This is a record copy of a test procedure for application of the full-scale shear vane to underground waste tanks at Hanford. The introduction of the report provides background information on the development and proof-testing of the shear vane, as well as information about its current location. The document was originally prepared in 1988, and the work as shelved temporarily for lack of funds. Activities to utilize the shear vane will be expedited by use of this information

  8. Operativ behandling af thoracic outlet syndrome

    DEFF Research Database (Denmark)

    Birkeland, Peter; Stiasny, Jerzy

    2012-01-01

    of the brachial plexus. At surgery, we found and severed a fibrous band that compressed the inferior trunk. Postoperatively, the pain subsided and fine hand movements improved. One patient had no cervical rib, however, in the two other cases we found rudimentary cervical ribs. Magnetic resonance imaging......We present three cases with longstanding true neurogenic thoracic outlet syndrome. All patients had aching pain in the shoulder, arm and ulnar border of the hand. On examination, we found atrophy of the hand muscles. Electromyography revealed signs of compromised function of the inferior trunk...

  9. Epidemiology and pathogenesis of thoracic outlet syndrome

    Directory of Open Access Journals (Sweden)

    Wojcik Gustaw

    2015-03-01

    Full Text Available The superior thoracic aperture is a place particularly vulnerable to the occurrence of tissue conflict and the development of a number of neurovascular changes carrying a risk of upper limb dysfunction. The triggering factor in this case is the pressure on the nerve vascular elements brought about by too large muscles of the chest and neck, clavicle fracture and dislocation of the upper ribs, anomalies in the form of ribs, in the neck, or by apex of the lung tumors. Each anatomical anomaly may be a cause of a number of lesions and lead to the development of the disease. Due to the nature of the oppressed structures, there are two basic groups: neurogenic and vascular. The most common variant giving clinical symptoms is neurogenic thoracic outlet syndrome. In this, the compression ratio, the brachial plexus, and for this reason, the vascular surface of the upper limb dysfunction is often overlooked. However, the vascular variant, and especially arterial sub-variant, is very dangerous because it can give complications even in the form of aneurysms, and even upper limb ischemia. The aim of the study is to present the most common changes in the thoracic outlet causing functional disorders of the upper limb.

  10. Performance improvement of a centrifugal compressor stage by using different vaned diffusers

    International Nuclear Information System (INIS)

    Zhang, Y C; Kong, X Z; Li, F; Sun, W; Chen, Q G

    2013-01-01

    The vaneless diffuser (VLD) is usually adopted in the traditional design of the multi-stage centrifugal compressor because of the stage's match problem. The drawback of the stage with vaneless diffusers is low efficiency. In order to increase the efficiency and at the same time, induce no significant decline in the operating range of the stage, three different types of vaned diffusers are designed and numerically investigated: the traditional vaned diffuser (TVD), the low-solidity cascade diffuser (LSD) and the partial-height vane diffuser (PVD). These three types of vaned diffusers have different influences on the performance of the centrifugal compressor. In the present investigation, the first part investigates the performance of a centrifugal compressor stage with three different vaned diffusers. The second part studies the influences of the height and the position of partial height vanes on the stage performance, and discusses the matching problem between the PVD and the downstream return channel. The stage investigated in this paper includes the impeller, the diffuser, the bend and the return channel. In the process of numerical investigation, the flow is assumed to be steady, and this process includes calculation and simulation. The calculation of 3-D turbulent flow in the stage uses the commercial CFD code NUMECA together with the Spalart-Allmaras turbulence model. The simulation of the computational region includes the impeller passages, the diffuser passages and return channel passages. The structure and surrounding region are assumed to have a perfect cyclic symmetry, so the single channel model and periodic boundary condition are applied at the middle of the passage, that is to reduce the calculation region to only one region. The investigation showed that the low-solidity cascade diffuser would be a better choice as a middle course for the first stage of the multistage centrifugal compressor. Besides, the influences of the height and the position

  11. Design and numerical investigation of swirl recovery vanes for the Fokker 29 propeller

    Directory of Open Access Journals (Sweden)

    Wang Yangang

    2014-10-01

    Full Text Available Swirl recovery vanes (SRVs are a set of stationary vanes located downstream from a propeller, which may recover some of the residual swirl from the propeller, hoping for an improvement in both thrust and efficiency. The SRV concept design for a scaled version representing the Fokker 29 propeller is performed in this paper, which may give rise to a promotion in propulsive performance of this traditional propeller. Firstly the numerical strategy is validated from two aspects of global quantities and the local flow field of the propeller compared with experimental data, and then the exit flow together with the development of propeller wake is analyzed in detail. Three kinds of SRV are designed with multiple circular airfoils. The numerical results show that the swirl behind the propeller is recovered significantly with Model V3, which is characterized by the highest solidity along spanwise, for various working conditions, and the combination of rotor and vane produced 5.76% extra thrust at the design point. However, a lower efficiency is observed asking for a better vane design and the choice of a working point. The vane position is studied which shows that there is an optimum range for higher thrust and efficiency.

  12. Temperature measurements at the LMFBR core outlet

    International Nuclear Information System (INIS)

    Argous, J.P.; Berger, R.; Casejuane, R.; Fournier, C.; Girard, J.P.

    1980-04-01

    Over the last few years the temperature sensors used to measure the subassembly outlet temperature in French designed LMFBRs have been modified, basically in an effort to reduce the dispersion of the chromel-alumel thermocouple time constant, and to extend the frequency spectrum of the measurement signals by adding a steel electrode to from a stainless steel-sodium thermocouple. The result of this evolution is the temperature probe immersed in sodium which will be used in the SUPER PHENIX reactor. This paper describes the tests already completed or in progress on this probe. It also presents measurement data on the two basic probe parameters: the thermoelectric power of the stainless steel-sodium thermocouple and the time constant of the chromel-alumel thermocouple

  13. Electrical Power Quality - What's Behind the Outlet?

    Science.gov (United States)

    Baird, William H.; Secrest, Jeffery; Padgett, Clifford

    2017-09-01

    Although we may consider the power outlets in our homes to be nearly ideal voltage sources, a variety of influences in and around the home can cause departures from the nominal 60 Hz, 110-120 V root-mean-square (rms) of the North American grid. Even without instrumentation, we can see that a large motor starting from rest can be sufficient to cause lights to dim momentarily (voltage sag). This dimming is due to the inrush current drawn by a stationary motor, which may be several times the current drawn at operating speed. We prepared a voltage monitoring system using a voltage divider, the construction details of which we omit in the interest of safety.

  14. Enlarging the operation range of a centrifugal compressor by cutting vanes based on CFD

    International Nuclear Information System (INIS)

    Mo, J T; Pan, X H; Gu, C H; Zheng, S Y

    2013-01-01

    Many centrifugal compressors are liable to insufficient operation range. The purpose of this paper is to enlarge the operation range of a centrifugal compressor used in turbocharger by cutting vanes. Some numerical works have been done based on CFD. The comparison of the calculated and measured results shows good agreement. The overall performance characteristics of the centrifugal compressor with different cutted vanes are observed and analyzed. The performance characteristic curves show that cutting vanes can increase the operation range by more than 50% with the loss of the highest efficiency limited in 1%. The flow fields are also shown in this paper and related explanations about the change of the performance characteristics curves are given. Shock wave is also detected in the simulation, and some related characteristics are summed up

  15. Performance Analysis of a Centrifugal Compressor for HFC-134a with aviation of Diffuser Vane Angle

    International Nuclear Information System (INIS)

    Park, Han Young; Chung, Jin Taek; Shin, You Hwan; Lee, Yoon Pyo; Kim, Kwang Ho; Cho, Yong Hun; Kim, Jong Seong

    2007-01-01

    Numerical simulation on the two-stage centrifugal compressor with Low Solidity Vaned Diffuser (LSVD) for HFC-134a turbo-chiller was performed using a commercial code. The comparative study with experimental results from other compressor was also investigated to testify the simulation schemes. The numerical analysis was separately simulated for each stage of the compressor and the effect of impeller-diffuser flow interaction was considered. Setting angle of the diffuser vane changed in the range of 15 .deg. and the effects on its variation were discussed in detail including the flow analysis in the passage of the compressor. The vane setting angle obtained from the preliminary design was slightly adjusted to the optimal value by the performance enhancement in terms of pressure recovery and flow characteristics

  16. A Comparative Analysis of the Distributions of KFC and McDonald’s Outlets in China

    Directory of Open Access Journals (Sweden)

    Yikang Rui

    2016-03-01

    Full Text Available Mainland China has become one of the most important markets for international fast-food chains over the past decade. To study the regional spread of KFC and McDonald’s outlets in Chinese cities, the correlation of their distributions and degree of market expansion were explored and compared to analyze both the local and the global spatial autocorrelations. A geographically weighted Poisson regression model was also used to examine the influence of demographic, economic, and geographic factors on their spatial distributions. The findings of this comparative study reveal the site selection criteria at the city level by studying the differences and similarities in outlet distributions for KFC and McDonald’s. The presented results can guide other chains to enhance business location planning and formulate regional development policy.

  17. CFD analysis of supercritical water flow and heat transfer in single channel with mixing vane

    International Nuclear Information System (INIS)

    Zuo Guoping; Xie Hongyan; Yu Tao

    2012-01-01

    Three-dimensional rectangular channel with the mixing wane in supercritical water reactor is investigated with CFX. The mixing vane elevation influenced on temperature distribution and flow field are simulated in the model. The results showed the mixing vane cause fluid circumferential flow, making flow hot and cold fluids mixed and fluid temperature uniform distribution, effectively improve the fuel rod surface temperature distribution and reduced hot temperature. Among the mixing wing elevation of 15, 30, 45, 50, 60 and 70 angle, the 30 angle is the best case in improving temperature distribution. (authors)

  18. Reduction of background noise induced by wind tunnel jet exit vanes

    Science.gov (United States)

    Martin, R. M.; Brooks, T. F.; Hoad, D. R.

    1985-01-01

    The NASA-Langley 4 x 7 m wind tunnel develops low frequency flow pulsations at certain velocity ranges during open throat mode operation, affecting the aerodynamics of the flow and degrading the resulting model test data. Triangular vanes attached to the trailing edge of flat steel rails, mounted 10 cm from the inside of the jet exit walls, have been used to reduce this effect; attention is presently given to methods used to reduce the inherent noise generation of the vanes while retaining their pulsation reduction features.

  19. Effects of the friction coefficient on the torque characteristics of a hydraulic cam-rotor vane motor

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Qiankun; Wang, Xuyong; Yuan, Fan; Chen, Liang Shen; Tao, Jian Feng [School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai (China); Miao, Zhong Hua [School of Mechatronic Engineering and Automation, Shanghai University, Shanghai (China)

    2016-08-15

    The friction coefficient between the vane and the slot is one of the most critical factors that affects the performance of a continuous rotary hydraulic cam-rotor vane motor. To study the effects of this coefficient on the torque characteristics of the motor, the mathematical model for the normal force and the disturbing torque between the cam rotors and the vanes of the motor was established by analyzing the forces exerted on the vanes. The mathematical model was simulated with MATLAB, and simulation results show that an increase in the friction coefficient would simultaneously decrease the normal force and increase the disturbing torque, which would negatively affect the performance of the motor. Further experimental research indicated that the low-speed performance of the hydraulic cam-rotor motor was significantly improved when the friction coefficient was reduced by controlling the parallelism tolerance, flatness and roughness between the vanes and the slots.

  20. Static thrust-vectoring performance of nonaxisymmetric convergent-divergent nozzles with post-exit yaw vanes. M.S. Thesis - George Washington Univ., Aug. 1988

    Science.gov (United States)

    Foley, Robert J.; Pendergraft, Odis C., Jr.

    1991-01-01

    A static (wind-off) test was conducted in the Static Test Facility of the 16-ft transonic tunnel to determine the performance and turning effectiveness of post-exit yaw vanes installed on two-dimensional convergent-divergent nozzles. One nozzle design that was previously tested was used as a baseline, simulating dry power and afterburning power nozzles at both 0 and 20 degree pitch vectoring conditions. Vanes were installed on these four nozzle configurations to study the effects of vane deflection angle, longitudinal and lateral location, size, and camber. All vanes were hinged at the nozzle sidewall exit, and in addition, some were also hinged at the vane quarter chord (double-hinged). The vane concepts tested generally produced yaw thrust vectoring angles much less than the geometric vane angles, for (up to 8 percent) resultant thrust losses. When the nozzles were pitch vectored, yawing effectiveness decreased as the vanes were moved downstream. Thrust penalties and yawing effectiveness both decreased rapidly as the vanes were moved outboard (laterally). Vane length and height changes increased yawing effectiveness and thrust ratio losses, while using vane camber, and double-hinged vanes increased resultant yaw angles by 50 to 100 percent.

  1. ''VaneCAM'' - the third generation of camshaft adjustment systems; ''VaneCAM'' - Nockenwellenversteller der dritten Generation

    Energy Technology Data Exchange (ETDEWEB)

    Knecht, A. [Hydraulik-Ring GmbH, Nuertingen (Germany). Entwicklung Motorentechnik; Stephan, W. [Hydraulik-Ring GmbH, Nuertingen (Germany); Hannibal, W. [Fachhochschule Suedwestfalen, Iserlohn (Germany). Labor fuer Konstruktion und CAE-Anwendungen

    2002-04-01

    Continuously variable camphasers are now well established for modern spark-ignition engines in high-volume production. With the latest generation of camshaft adjustment systems using the vane-type actuator principle, it is possible to move rapidly and reliably through a large adjustment angle. The layout of these adjusting systems is very simple. The production costs are low in comparison to the first generation of camphasers using spur/helical gears to vary the valve timing. The new-generation systems are mechatronic, with the function depending on the coordination and tuning of hydraulic actuation and engine electronics. The term 'VaneCAM' is used for the continuously variable systems of this new generation supplied by Hydraulik-Ring in Nuertingen, Germany. (orig.) [German] Stufenlos wirkende Nockenwellenversteller haben sich an modernen Ottomotoren in den letzten Jahren in der Grossserie etabliert. Mit der neuesten Generation von Nockenwellenverstellern, die nach dem Schwenkmotor-Prinzip aufgebaut sind, lassen sich grosse Verdrehwinkel sehr schnell und betriebssicher verstellen. Der Aufbau dieser Versteller ist einfach, und die Herstellkosten sind gering im Vergleich zur ersten Generation von Verstellern. Bei den Systemen der neuen Generation handelt es sich um mechatronische Systeme, deren Funktion von dem Zusammenspiel und der Abstimmung von hydraulischer Ansteuerung und Motorelektronik abhaengt. Mit dem Begriff 'VaneCAM' werden die stufenlos wirkenden Systeme dieser neuen Generation von Hydraulik-Ring aus Nuertingen bezeichnet. (orig.)

  2. Numerical and Experimental Investigations of Design Parameters Defining Gas Turbine Nozzle Guide Vane Endwall Heat Transfer

    OpenAIRE

    Rubensdörffer, Frank G.

    2006-01-01

    The primary requirements for a modern industrial gas turbine consist of a continuous trend of an increasing efficiency combined with very low emissions in a robust, cost-effective manner. To fulfil these tasks a high turbine inlet temperature together with advanced dry low NOX combustion chambers are employed. These dry low NOX combustion chambers generate a rather flat temperature profile compared to previous generation gas turbines, which have a rather parabolic temperature profile before t...

  3. Benign Strictures of the Esophagus and Gastric Outlet: Interventional Management

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hyoung; Shin, Ji Hoon; Song, Ho Young [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2010-10-15

    Benign strictures of the esophagus and gastric outlet are difficult to manage conservatively and they usually require intervention to relieve dysphagia or to treat the stricture-related complications. In this article, authors review the non-surgical options that are used to treat benign strictures of the esophagus and gastric outlet, including balloon dilation, temporary stent placement, intralesional steroid injection and incisional therapy

  4. Gastric Outlet Obstruction from Duodenal Lipoma in an Adult ...

    African Journals Online (AJOL)

    Gastric Outlet Obstruction from Duodenal Lipoma in an Adult. ... Nigerian Journal of Surgery ... Although, peptic ulcer disease remains the most common benign cause of gastric outlet obstruction (GOO), duodenal lipomas remain a rare, but possible cause of GOO and could pose a diagnostic challenge, especially in ...

  5. Ectopic pancreas causing partial gastric outlet obstruction: a case ...

    African Journals Online (AJOL)

    Ectopic pancreas causing partial gastric outlet obstruction: a case report and review of literature. ... Nigerian Journal of Surgery ... Gastric outlet obstruction resulting from ectopic pancreas in an adult is the first of its kind in our center; we, therefore, present this case to describe the challenges faced with diagnosis, treatment, ...

  6. Tobacco Retail Outlets and Vulnerable Populations in Ontario, Canada

    Directory of Open Access Journals (Sweden)

    Michael O. Chaiton

    2013-12-01

    Full Text Available Interest has been increasing in regulating the location and number of tobacco vendors as part of a comprehensive tobacco control program. The objective of this paper is to examine the distribution of tobacco outlets in a large jurisdiction, to assess: (1 whether tobacco outlets are more likely to be located in vulnerable areas; and (2 what proportion of tobacco outlets are located close to schools. Retail locations across the Province of Ontario from Ministry of Health Promotion data were linked to 2006 Census data at the neighbourhood level. There was one tobacco retail outlet for every 1,000 people over age 15 in Ontario. Density of outlets varied by public health unit, and was associated with the number of smokers. Tobacco outlets were more likely to be located in areas that had high neighbourhood deprivation, in both rural and urban areas. Outlets were less likely to be located in areas with high immigrant populations in urban areas, with the reverse being true for rural areas. Overall, 65% of tobacco retailers were located within 500 m of a school. The sale of tobacco products is ubiquitous, however, neighbourhoods with lower socio-economic status are more likely to have easier availability of tobacco products and most retailers are located within walking distance of a school. The results suggest the importance of policies to regulate the location of tobacco retail outlets.

  7. Off-premise alcohol outlet characteristics and violence.

    Science.gov (United States)

    Snowden, Aleksandra J; Pridemore, William Alex

    2014-07-01

    There is considerable evidence of an association between alcohol outlet density and violence. Although prior research reveals the importance of specific characteristics of bars on this association and that the relationship between bar density and violence may be moderated by these characteristics, there are few similar studies of the characteristics of off-premise outlets (e.g., liquor and convenience stores). We examined whether immediate environment, business practice, staff, and patron characteristics of off-premise alcohol outlets are associated with simple and aggravated assault density. Cross-sectional design using aggregate data from 65 census block groups in a non-metropolitan college town, systematic social observation, and spatial modeling techniques. We found limited effects of immediate environment, business practice, staff, and patron characteristics on simple assault density and no effect on aggravated assault density. Only two out of 17 characteristics were associated with simple assault density (i.e., nearby library and male patrons). This is the first study to examine the association between several off-premise alcohol outlet characteristics and assault. Our findings suggest that where the off-premise outlets are located, how well the immediate environment is maintained, what types of beverages the outlets sell, who visits them, and who works there matter little in their association with violence. This suggests the importance of outlet density itself as a primary driver of any association with violence. Public policies aimed at reducing alcohol outlet density or clustering may be useful for reducing violence.

  8. Ectopic Pancreas Causing Partial Gastric Outlet Obstruction: A Case ...

    African Journals Online (AJOL)

    Ectopic pancreas is a rare cause of gastric outlet obstruction, perhaps rarer still among Africans. Although the entity is known, the diagnostic challenges are enormous, especially in the poor‑resource environment. Gastric outlet obstruction resulting from ectopic pancreas in an adult is the first of its kind in our center;.

  9. Alcohol Outlets and Violent Crime in Washington D.C.

    Directory of Open Access Journals (Sweden)

    Pan, William K

    2010-08-01

    Full Text Available Objective: Alcohol is more likely than any other drug to be involved in substance-related violence. In 2000 violence-related and self-directed injuries accounted for an estimated $37 billion and $33 billion in productivity losses and medical treatment, respectively. A review of emergency department data revealed violence and clinically identified trauma-related injuries have the strongest correlation among alcohol-dependent injuries. At the environmental level there is a relationship between alcohol outlet density and violent crime. A limited number of studies have examined the relationship between alcohol outlet type and the components of violent crime. The aim of this study is to examine the relationship between the aggregate components of violent crime and alcohol outlet density by type of outlet.Methods: For this study we used Washington, D.C. census tract data from the 2000 census to examine neighborhood characteristics. Alcohol outlet, violent crime, and population-level data for Washington, D.C. were drawn from various official yet publicly available sources. We developed an analytic database to examine the relationship between alcohol outlet category and four types of violent crime. After estimating spatial correlation and determining spatial dependence, we used a negative binomial regression analysis to assess the alcohol availability-violent crime association, while controlling for structural correlates of violence.Results: Independent of alternative structural correlates of violent crime, including the prevalence of weapons and illicit drugs, community-level alcohol outlet density is significantly associated with assaultive violence. Outlets were significantly related to robbery, assault, and sexual offenses. In addition, the relationship among on-premise and off-premise outlets varied across violent crime categories.Conclusion: In Washington, D.C., alcohol outlet density is significantly associated with the violent crimes. The

  10. The geography of Fast Food outlets: a review.

    Science.gov (United States)

    Fraser, Lorna K; Edwards, Kimberly L; Cade, Janet; Clarke, Graham P

    2010-05-01

    The availability of food high in fat, salt and sugar through Fast Food (FF) or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity.

  11. The Geography of Fast Food Outlets: A Review

    Directory of Open Access Journals (Sweden)

    Lorna K. Fraser

    2010-05-01

    Full Text Available The availability of food high in fat, salt and sugar through Fast Food (FF or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity.

  12. Coolant mixing in the LMFBR outlet plenum

    International Nuclear Information System (INIS)

    Chen, Y.B.; Golay, M.W.

    1977-06-01

    Small scale experiments involving water flows are used to provide mean flow and turbulence field data for LMFBR outlet plenum flows. Measurements are performed at Reynolds Number (Re) values of 33000 and 70000 in a 1/15-scale FFTF geometry and at Re = 35000 in a 3/80-scale CRBR geometry. The experimental behavior is predicted using two different turbulence model computer programs, TEACH-T and VARR-II. It is found that the qualitative nature of the flow field within the plenum depends strongly upon the distribution of the mean inlet velocity field, upon the degree of inlet turbulence, and upon the turbulence momentum exchange model used in the calculations. It is found in the FFTF geometry that the TEACH-T predictions are better than that of VARR-II, and in the CRBR geometry neither code provides a good prediction of the observed behavior. From the sensitivity analysis, it is found that the production and dissipation of turbulence are the dominant terms in the transport equations for turbulent kinetic energy and turbulent energy dissipation rate, and the diffusion terms are relatively small. From the same study a new set of empirical constants for the turbulence model is evolved for the prediction of plenum flows

  13. Experimental Investigation of Turbine Vane Heat Transfer for Alternative Fuels

    Energy Technology Data Exchange (ETDEWEB)

    Nix, Andrew Carl [West Virginia Univ., Morgantown, WV (United States)

    2015-03-23

    The focus of this program was to experimentally investigate advanced gas turbine cooling schemes and the effects of and factors that contribute to surface deposition from particulate matter found in coal syngas exhaust flows on turbine airfoil heat transfer and film cooling, as well as to characterize surface roughness and determine the effects of surface deposition on turbine components. The program was a comprehensive, multi-disciplinary collaborative effort between aero-thermal and materials faculty researchers and the Department of Energy, National Energy Technology Laboratory (NETL). The primary technical objectives of the program were to evaluate the effects of combustion of syngas fuels on heat transfer to turbine vanes and blades in land-based power generation gas turbine engines. The primary questions to be answered by this investigation were; What are the factors that contribute to particulate deposition on film cooled gas turbine components? An experimental program was performed in a high-temperature and pressure combustion rig at the DOE NETL; What is the effect of coal syngas combustion and surface deposition on turbine airfoil film cooling? Deposition of particulate matter from the combustion gases can block film cooling holes, decreasing the flow of the film coolant and the film cooling effectiveness; How does surface deposition from coal syngas combustion affect turbine surface roughness? Increased surface roughness can increase aerodynamic losses and result in decreased turbine hot section efficiency, increasing engine fuel consumption to maintain desired power output. Convective heat transfer is also greatly affected by the surface roughness of the airfoil surface; Is there any significant effect of surface deposition or erosion on integrity of turbine airfoil thermal barrier coatings (TBC) and do surface deposits react with the TBC in any way to decrease its thermal insulating capability? Spallation and erosion of TBC is a persistent problem in

  14. the screw-conveyor vane design for piece-wise construction

    African Journals Online (AJOL)

    Dr Obe

    Summary. One of the long-used methods of conveying granular, Powdery or slurry material is by the screw conveyor. This method of transport is well suited to some at the needs of local processing Industries based on such local produce as millet, maize, cocoa-beans, rice, palm-kernels. The spiral vanes of such conveyors ...

  15. Performance of an alpha-vane and pitot tube in simulated heavy rain environment

    Science.gov (United States)

    Luers, J. K.; Fiscus, I. B.

    1985-01-01

    Experimental tests were conducted in the UDRI Environmental Wind/Rain Tunnel to establish the performance of an alpha-vane, that measures angle of attack, in a simulated heavy rain environment. The tests consisted of emersing the alpha-vane in an airstream with a concurrent water spray penetrating vertically through the airstream. The direction of the spray was varied to make an angle of 5.8 to 18 deg with the airstream direction in order to simulate the conditions that occur when an aircraft lands in a heavy rain environment. Rainrates simulated varied from 1000 to 1200 mm/hr which are the most severe ever expected to be encountered by an aircraft over even a 30 second period. Tunnel airspeeds ranged from 85 to 125 miles per hour. The results showed that even the most severe rainrates produced a misalignment in the alpha-vane of only 1 deg away from the airstream direction. Thus for normal rain conditions experienced by landing aircraft no significant deterioration in alpha-vane performance is expected.

  16. Numerical Study of Bubble Coalescence and Breakup in the Reactor Fuel Channel with a Vaned Grid

    Directory of Open Access Journals (Sweden)

    Tenglong Cong

    2018-01-01

    Full Text Available The characteristics of bubbles of different sizes in fuel assembly are vital to two-phase flow resistance and heat transfer capacity. However, due to the swirl flow caused by the mixing vane, bubbles can crowd at the heated surface, which may anticipate the occurrence of departure from nucleation boiling. In the current work, the adiabatic two-phase flow in a simplified fuel assembly was analyzed by using the Eulerian two-fluid model and the MUSIG (MUltiple SIze Group model. This computational domain consists of two coolant channels and two sets of vaned spacers, with three sets of periodic boundary conditions at the side faces of the domain. The distributions of vapor phase and bubble diameters were obtained, based on which the effects of mixing vanes on the bubble characteristics were analyzed. Vapor phase crowded at the rod surface in the higher inlet vapor fraction case, but crowded in the channel center in the lower inlet vapor fraction cases. This work can be used as a reference for the design of mixing vanes to avoid the anticipation of departure of nucleation boiling that may be caused by unreasonable design.

  17. Analysis of swirl recovery vanes for increased propulsive efficiency in tractor propeller aircraft

    NARCIS (Netherlands)

    Veldhuis, L.L.M.; Stokkermans, T.C.A.; Sinnige, T.; Eitelberg, G.

    2016-01-01

    In this paper we address a preliminary assessment of the performance effects of swirl recovery vanes (SRVs) in a installed and uninstalled tractor propeller arrangement. A numerical analysis was performed on a propeller and a propeller-wing configuration after the SRVs were optimized first in a

  18. MRI findings in thoracic outlet syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Aralasmak, Ayse; Sharifov, Rasul; Kilicarslan, Rukiye; Alkan, Alpay [Bezmialem Vakif University, Department of Radiology, Fatih/Istanbul (Turkey); Cevikol, Can; Karaali, Kamil; Senol, Utku [Akdeniz University, Department of Radiology, Antalya (Turkey)

    2012-11-15

    We discuss MRI findings in patients with thoracic outlet syndrome (TOS). A total of 100 neurovascular bundles were evaluated in the interscalene triangle (IS), costoclavicular (CC), and retropectoralis minor (RPM) spaces. To exclude neurogenic abnormality, MRIs of the cervical spine and brachial plexus (BPL) were obtained in neutral. To exclude compression on neurovascular bundles, sagittal T1W images were obtained vertical to the longitudinal axis of BPL from spinal cord to the medial part of the humerus, in abduction and neutral. To exclude vascular TOS, MR angiography (MRA) and venography (MRV) of the subclavian artery (SA) and vein (SV) in abduction were obtained. If there is compression on the vessels, MRA and MRV of the subclavian vessels were repeated in neutral. Seventy-one neurovascular bundles were found to be abnormal: 16 arterial-venous-neurogenic, 20 neurogenic, 1 arterial, 15 venous, 8 arterial-venous, 3 arterial-neurogenic, and 8 venous-neurogenic TOS. Overall, neurogenic TOS was noted in 69%, venous TOS in 66%, and arterial TOS in 39%. The neurovascular bundle was most commonly compressed in the CC, mostly secondary to position, and very rarely compressed in the RPM. The cause of TOS was congenital bone variations in 36%, congenital fibromuscular anomalies in 11%, and position in 53%. In 5%, there was unilateral brachial plexitis in addition to compression of the neurovascular bundle. Severe cervical spondylosis was noted in 14%, contributing to TOS symptoms. For evaluation of patients with TOS, visualization of the brachial plexus and cervical spine and dynamic evaluation of neurovascular bundles in the cervicothoracobrachial region are mandatory. (orig.)

  19. Acute Alcohol Consumption, Alcohol Outlets, and Gun Suicide

    Science.gov (United States)

    Branas, Charles C.; Richmond, Therese S.; Ten Have, Thomas R.; Wiebe, Douglas J.

    2014-01-01

    A case–control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed. PMID:21929327

  20. The image evaluation of iterative motion correction reconstruction algorithm PROPELLER T2-weighted imaging compared with MultiVane T2-weighted imaging

    Science.gov (United States)

    Lee, Suk-Jun; Yu, Seung-Man

    2017-08-01

    The purpose of this study was to evaluate the usefulness and clinical applications of MultiVaneXD which was applying iterative motion correction reconstruction algorithm T2-weighted images compared with MultiVane images taken with a 3T MRI. A total of 20 patients with suspected pathologies of the liver and pancreatic-biliary system based on clinical and laboratory findings underwent upper abdominal MRI, acquired using the MultiVane and MultiVaneXD techniques. Two reviewers analyzed the MultiVane and MultiVaneXD T2-weighted images qualitatively and quantitatively. Each reviewer evaluated vessel conspicuity by observing motion artifacts and the sharpness of the portal vein, hepatic vein, and upper organs. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by one reviewer for quantitative analysis. The interclass correlation coefficient was evaluated to measure inter-observer reliability. There were significant differences between MultiVane and MultiVaneXD in motion artifact evaluation. Furthermore, MultiVane was given a better score than MultiVaneXD in abdominal organ sharpness and vessel conspicuity, but the difference was insignificant. The reliability coefficient values were over 0.8 in every evaluation. MultiVaneXD (2.12) showed a higher value than did MultiVane (1.98), but the difference was insignificant ( p = 0.135). MultiVaneXD is a motion correction method that is more advanced than MultiVane, and it produced an increased SNR, resulting in a greater ability to detect focal abdominal lesions.

  1. Performance improvement of centrifugal compressor stage with pinched geometry or vaned diffuser

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen, A.

    2009-07-01

    Centrifugal compressors are widely used for example in refrigeration processes, the oil and gas industry, superchargers, and waste water treatment. In this work, five different vaneless diffusers and six different vaned diffusers are investigated numerically. The vaneless diffusers vary only by their diffuser width, so that four of the geometries have pinch implemented to them. Pinch means a decrease in the diffuser width. Four of the vaned diffusers have the same vane turning angle and a different number of vanes, and two have different vane turning angles. The flow solver used to solve the flow fields is Finfo, which is a Navier-Stokes solver. All the cases are modeled Chien's k-epsilon turbulence model. All five vaneless diffusers and three vaned diffusers are investigated also experimentally. For each construction, the compressor operating map is measured according to relevant standards. In addition to this, the flow fields before and after the diffuser are measured with static and total pressure, flow angle and total temperature measurements k-omega SST turbulence model. The simulation results indicate that it is possible to improve the efficiency with the pinch, and according to the numerical results, the two best geometries are the ones with most pinch at the shroud. These geometries have approximately 4 percentage points higher effciency than the unpinched vaneless diffusers. The hub pinch does not seem to have any major benefits. In general, the pinches make the flow fields before and after the diffuser more uniform. The pinch also seems to improve the impeller effciency. This is down to two reasons. The major reason is that the pinch decreases the size of slow flow and possible backflow region located near the shroud after the impeller. Secondly, the pinches decrease the flow velocity in the tip clearance, leading to a smaller tip leakage flow and therefore slightly better impeller efficiency. Also some of the vaned diffusers improve the efficiency

  2. The 3D thermal-hydraulic numerical simulation for the fuel zone outlet of China experimental fast reactor

    International Nuclear Information System (INIS)

    Xue Xiuli; Yang Hongyi; Yang Fuchang

    2008-01-01

    Detailed 3D thermal-hydraulic numerical analyses to the fuel zone outlet are actualized with the STAR-CD CFD code. The performance of sodium mixing is studied and detailed velocity and temperature distribution are obtained in this region which will offer foundations and references to study the rationality of temperature monitoring-spot arrangement and to assess the effect of temperature fluctuations to control rod guide tubes in this region, and so on. (authors)

  3. PIV measurement at the blowdown pipe outlet

    International Nuclear Information System (INIS)

    Puustinen, M.; Laine, J.; Raesaenen, A.; Pyy, L.; Telkkae, J.

    2013-04-01

    This report summarizes the findings of the PIV measurement tests carried out in January - February 2013 with the scaled down PPOOLEX test facility at LUT. The main objective of the tests was to find out the operational limits of the PIV system regarding suitable test conditions and correct values of different adjustable PIV parameters. An additional objective was to gather CFD grade data for verification/validation of numerical models. Both water and steam injection tests were carried out. PIV measurements with cold water injection succeeded well. Raw images were of high quality, averaging over the whole measurement period could be done and flow fields close to the blowdown pipe outlet could be determined. In the warm water injection cases the obtained averaged velocity field images were harder to interpret, especially if the blowdown pipe was also filled with warm water in the beginning of the measurement period. The absolute values of the velocity vectors seemed to be smaller than in the cold water injection cases. With very small steam flow rates the steam/water interface was inside the blowdown pipe and quite stable in nature. The raw images were of good quality but due to some fluctuation in the velocity field averaging of the velocity images over the whole measured period couldn't be done. Condensation of steam in the vicinity of the pipe exit probably caused these fluctuations. A constant outflow was usually followed by a constant inflow towards the pipe exit. Vector field images corresponding to a certain phase of the test could be extracted and averaged but this would require a very careful analysis so that the images could be correctly categorized. With higher steam flow rates rapid condensation of large steam bubbles created small gas bubbles which were in front of the measurement area of the PIV system. They disturbed the measurements by reflecting laser light like seeding particles and therefore the raw images were of poor quality and they couldn't be

  4. 7 CFR 993.108 - Non-human consumption outlet.

    Science.gov (United States)

    2010-01-01

    ... consumption outlet means any livestock feeder or manufacturer of inedible syrup, industrial alcohol, animal... FR 8278, Sept. 2, 1961; 26 FR 8483, Sept. 9, 1961] Effective Date Note: At 70 FR 30613, May 27, 2005...

  5. Methodological Approaches to Locating Outlets of the Franchise Retail Network

    OpenAIRE

    Grygorenko Tetyana M.

    2016-01-01

    Methodical approaches to selecting strategic areas of managing the future location of franchise retail network outlets are presented. The main stages in the assessment of strategic areas of managing the future location of franchise retail network outlets have been determined and the evaluation criteria have been suggested. Since such selection requires consideration of a variety of indicators and directions of the assessment, the author proposes a scale of evaluation, which ...

  6. The effect of grid assembly mixing vanes on critical heat flux values and azimuthal location in fuel assemblies

    International Nuclear Information System (INIS)

    De Crecy, F.

    1994-01-01

    Critical heat flux (CHF) is one of the limiting phenomena for a PWR. It has been widely studied for years, but many facts are still not satisfactorily understood. This paper deals with the effect of the grid assembly mixing vanes on both the value of the CHF and the azimuthal location of the departure from nucleate boiling (DNB). A series of experimental studies was performed on electrically heated, 5x5 square pitched, vertical rod bundles. Two specific grid assembly designs were used: with and without mixing vanes. DNB was detected by eight thermocouples welded internally in each rod at the same level in order to determine the azimuthal location. The coolant was Freon-12 flowing upwards to simulate high pressure water (as defined by Stevens). Single-phase flow experiments were also conducted to measure the exit temperature field in order to obtain the mixing coefficients for subchannel analysis.The results show very clearly that the mixing vanes have a significant effect on both the DNB azimuthal location and the CHF value. - Without mixing vanes, DNB occurs mainly on the most central rod and preferentially at the azimuthal location facing the adjacent rod. - With mixing vanes, DNB can occur on any of the nine central rods and is distributed in an apparently random way around the rod. -The effect of the mixing vanes on CHF is dramatic and depends a great deal on the parameter range (pressure, local mass velocity and local quality). Generally speaking, CHF with mixing vanes is significantly higher than without mixing vanes, but this effect can be inverted in some cases.In order to understand this fact more clearly, it is necessary to perform detailed analysis of subchannel behavior. Indeed, the analyses show that the magnitude of this effect is closely related to the mixing coefficients used. These mixing coefficients, estimated from the single-phase flow experiments, are subject to large uncertainties in two-phase flow. ((orig.))

  7. Gas turbine structural mounting arrangement between combustion gas duct annular chamber and turbine vane carrier

    Science.gov (United States)

    Wiebe, David J.; Charron, Richard C.; Morrison, Jay A.

    2016-10-18

    A gas turbine engine ducting arrangement (10), including: an annular chamber (14) configured to receive a plurality of discrete flows of combustion gases originating in respective can combustors and to deliver the discrete flows to a turbine inlet annulus, wherein the annular chamber includes an inner diameter (52) and an outer diameter (60); an outer diameter mounting arrangement (34) configured to permit relative radial movement and to prevent relative axial and circumferential movement between the outer diameter and a turbine vane carrier (20); and an inner diameter mounting arrangement (36) including a bracket (64) secured to the turbine vane carrier, wherein the bracket is configured to permit the inner diameter to move radially with the outer diameter and prevent axial deflection of the inner diameter with respect to the outer diameter.

  8. An Empirical Model for Vane-Type Vortex Generators in a Navier-Stokes Code

    Science.gov (United States)

    Dudek, Julianne C.

    2005-01-01

    An empirical model which simulates the effects of vane-type vortex generators in ducts was incorporated into the Wind-US Navier-Stokes computational fluid dynamics code. The model enables the effects of the vortex generators to be simulated without defining the details of the geometry within the grid, and makes it practical for researchers to evaluate multiple combinations of vortex generator arrangements. The model determines the strength of each vortex based on the generator geometry and the local flow conditions. Validation results are presented for flow in a straight pipe with a counter-rotating vortex generator arrangement, and the results are compared with experimental data and computational simulations using a gridded vane generator. Results are also presented for vortex generator arrays in two S-duct diffusers, along with accompanying experimental data. The effects of grid resolution and turbulence model are also examined.

  9. Heat transfer coefficient testing in nuclear fuel rod bundles with mixing vane grids

    International Nuclear Information System (INIS)

    Conner, Michael E.; Smith, L. David III; Holloway, Mary V.; Beasley, Donald E.

    2005-01-01

    An air heat transfer test facility was developed to test the heat transfer downstream of support grids in simulated PWR nuclear fuel rod bundles. The goal of this testing is to study the single-phase heat transfer coefficients downstream of grids with mixing vanes in a square-pitch rod bundle. The technique developed utilizes fully-heated grid spans and a specially designed thermocouple holder that can be moved axially down the rod bundle and aximuthally within a test rod. From this testing, the axial and aximuthally varying heat transfer coefficient can be determined. Different grid designs are tested and compared to determine the heat transfer enhancement associated with key grid features such as mixing vanes. (author)

  10. Aerodynamic forces estimation on jet vanes exposed to supersonic exhaust of a CD Nozzle

    International Nuclear Information System (INIS)

    Bukhari, S.B.H.; Jehan, I.; Zahir, S.; Khan, M.A.

    2003-01-01

    A comprehensive study has been made for the estimation of aerodynamic forces on the jet Vane placed in the supersonic exhaust of a Convergent Divergent, CD-Nozzle. Such a system is used to provide the control forces that consist of four orthogonal vanes mounted in the supersonic exhaust of the CD-Nozzles. The flow field parameters for a CD Nozzle were analyzed and validated earlier. In this paper the published experimental and CFD results from RAMPANT Code from Fluent Inc. were used to estimate the axial and normal forces by using PAK-3D, a Computational Fluid Dynamics (CFD) software based on Navier-Stokes Equations solver. Results got verified quantitatively with a maximum error of 8% between PAK-3D and experiment, while 4% between PAK-3D and a CFD code, RAMPANT for the axial force. (author)

  11. RF field measurement of a four-vane type RFQ with PISLs

    International Nuclear Information System (INIS)

    Ueno, A.; Yamajaki, Y.

    1992-01-01

    Field instability due to a dipole mode mixing is the most significant disadvantage of an original four-vane type radio-frequency quadrupole (RFQ) linac. In order to avoid any dipole mode mixing, several pairs of vane coupling rings (VCRs) have mainly been used so far. However the VCR has complicated shape and is difficult to fabricate, particularly in the RFQ linac operated with a high-duty factor. Thus, a new field-stabilization concept was proposed and was referred to as a π-mode stabilizing loop (PISL) in a previous paper. The results of rf characteristics measurements on a low-power model cavity with or without PISLs are presented in this paper. The measurements showed that the PISLs were capable of stabilizing the accelerating mode, reducing the ratio of a dipole mode mixing from 7% to less than 1.5% (Author) 4 figs., tab., 10 refs

  12. Background noise measurements from jet exit vanes designed to reduced flow pulsations in an open-jet wind tunnel

    Science.gov (United States)

    Hoad, D. R.; Martin, R. M.

    1985-01-01

    Many open jet wind tunnels experience pulsations of the flow which are typically characterized by periodic low frequency velocity and pressure variations. One method of reducing these fluctuations is to install vanes around the perimeter of the jet exit to protrude into the flow. Although these vanes were shown to be effective in reducing the fluctuation content, they can also increase the test section background noise level. The results of an experimental acoustic program in the Langley 4- by 7-Meter Tunnel is presented which evaluates the effect on tunnel background noise of such modifications to the jet exit nozzle. Noise levels for the baseline tunnel configuration are compared with those for three jet exit nozzle modifications, including an enhanced noise reduction configuration that minimizes the effect of the vanes on the background noise. Although the noise levels for this modified vane configuration were comparable to baseline tunnel background noise levels in this facility, installation of these modified vanes in an acoustic tunnel may be of concern because the noise levels for the vanes could be well above background noise levels in a quiet facility.

  13. Computational model for turbulent flow around a grid spacer with mixing vane

    International Nuclear Information System (INIS)

    Tsutomu Ikeno; Takeo Kajishima

    2005-01-01

    Turbulent mixing coefficient and pressure drop are important factors in subchannel analysis to predict onset of DNB. However, universal correlations are difficult since these factors are significantly affected by the geometry of subchannel and a grid spacer with mixing vane. Therefore, we propose a computational model to estimate these factors. Computational model: To represent the effect of geometry of grid spacer in computational model, we applied a large eddy simulation (LES) technique in couple with an improved immersed-boundary method. In our previous work (Ikeno, et al., NURETH-10), detailed properties of turbulence in subchannel were successfully investigated by developing the immersed boundary method in LES. In this study, additional improvements are given: new one-equation dynamic sub-grid scale (SGS) model is introduced to account for the complex geometry without any artificial modification; the higher order accuracy is maintained by consistent treatment for boundary conditions for velocity and pressure. NUMERICAL TEST AND DISCUSSION: Turbulent mixing coefficient and pressure drop are affected strongly by the arrangement and inclination of mixing vane. Therefore, computations are carried out for each of convolute and periodic arrangements, and for each of 30 degree and 20 degree inclinations. The difference in turbulent mixing coefficient due to these factors is reasonably predicted by our method. (An example of this numerical test is shown in Fig. 1.) Turbulent flow of the problem includes unsteady separation behind the mixing vane and vortex shedding in downstream. Anisotropic distribution of turbulent stress is also appeared in rod gap. Therefore, our computational model has advantage for assessing the influence of arrangement and inclination of mixing vane. By coarser computational mesh, one can screen several candidates for spacer design. Then, by finer mesh, more quantitative analysis is possible. By such a scheme, we believe this method is useful

  14. The effect of mixing-vane arrangements in a subchannel turbulent flow

    International Nuclear Information System (INIS)

    Ikeno, Tsutomu; Murata, Tamotsu; Kajishima, Takeo

    2006-01-01

    Large eddy simulation (LES) of developed turbulent flows in a rod bundle was carried out for four spacer designs. The mixing-vanes attached at the spacer were inclined at 30degC or 20deg; they were arranged to promote the swirling or convective flow. These arrangements are possible elements to compose an actual rod bundle. Our LES technique with a consistent higher-order immersed boundary method and a one-equation dynamic sub-grid scale model contributed to an efficient treatment of the complex wall configurations of rods and spacers. The computational results reasonably reproduced experimental results for the drag coefficient and the decay rate of swirling flow. The profiles of the axial velocities and the turbulence intensities indicated reasonable trend for the turbulent flow in the rod bundle. The effect of mixing-vane arrangement on the lateral flows was successfully clarified: the cross flow took the longer way on the rod surface than the swirling flow and then was more significantly influenced by momentum diffusion at the no-slip wall. Therefore, the largely inclined mixing-vanes promoted the cross flow only in the neighborhood of the spacer, the swirling flow inside a subchannel could reach farther downstream than the cross flow. (author)

  15. A Three-Dimensional Coupled Internal/External Simulation of a Film-Cooled Turbine Vane

    Science.gov (United States)

    Heidmann, James D.; Rigby, David L.; Ameri, Ali A.

    1999-01-01

    A three-dimensional Navier-Stokes simulation has been performed for a realistic film-cooled turbine vane using the LeRC-HT code. The simulation includes the flow regions inside the coolant plena and film cooling holes in addition to the external flow. The vane is the subject of an upcoming NASA Glenn Research Center experiment and has both circular cross-section and shaped film cooling holes. This complex geometry is modeled using a multi-block grid which accurately discretizes the actual vane geometry including shaped holes. The simulation matches operating conditions for the planned experiment and assumes periodicity in the spanwise direction on the scale of one pitch of the film cooling hole pattern. Two computations were performed for different isothermal wall temperatures, allowing independent determination of heat transfer coefficients and film effectiveness values. The results indicate separate localized regions of high heat transfer coefficient values, while the shaped holes provide a reduction in heat flux through both parameters. Hole exit data indicate rather simple skewed profiles for the round holes, but complex profiles for the shaped holes with mass fluxes skewed strongly toward their leading edges.

  16. Design optimization of a T mixing vane in nuclear fuel assembly

    International Nuclear Information System (INIS)

    Jung, Sang-Ho; Moon, Mi-Ae; Kim, Kwang-Yong

    2009-01-01

    The purposes of present work are to analyze the convective heat transfer with three-dimensional Reynolds-averaged Navier-Stokes analysis, and to optimize shape of the mixing vane using the analysis results. PLUS7 that is designed by KNF and Westinghouse is used as reference geometry. Shear stress transport turbulence model is used as a turbulence closure. Two bend angles of mixing vane are selected as design variable. The objective function is defined as a combination of inverse of heat transfer rate and friction loss. Response surface method is employed as an optimization technique. The calculation domains of 1x2 geometry are analyzed with translational and rotational periodic boundary conditions which take flow directions into account. The fluid flow and heat transfer characteristics have been explained through velocity vectors, streamlines and Nusselt numbers. The results show that the optimized geometry improves the heat transfer performance of the mixing vane with a relatively small pressure drop increment and has higher Critical Heat Flux. (author)

  17. Evaluation of alcohol outlet density and its relation with violence

    Directory of Open Access Journals (Sweden)

    Laranjeira Ronaldo

    2002-01-01

    Full Text Available OBJECTIVES: The current study set out to investigate alcohol availability in a densely populated, residential area of suburban São Paulo associated with high levels of social deprivation and violence. Gun-related deaths and a heavy concentration of alcohol outlets are notable features of the area surveyed. Given the strong evidence for a link between alcohol availability and a number of alcohol-related problems, including violent crime, measures designed to reduce accessibility have become a favored choice for alcohol prevention programs in recent years. METHODS: The interviewers were 24 residents of the area who were trained for the study. It was selected an area of nineteen streets, covering a total distance of 3.7 km. A profile of each alcohol outlet available on the area was recorded. RESULTS: One hundred and seven alcohol outlets were recorded. The number of other properties in the same area was counted at 1,202. Two measures of outlet density may thus be calculated: the number of outlets per kilometer of roadway (29 outlets/km; and the proportion of all properties that sold alcohol (1 in 12. CONCLUSIONS: The results of this study is compared with others which are mainly from developed countries and shown that the area studied have the highest density of alcohol outlet density ever recorded in the medical literature. The implication of this data related to the violence of the region is discussed. By generating a profile of alcohol sales and selling points, it was hoped to gain a better understanding of alcohol access issues within the sample area. Future alcohol prevention policy would be well served by such knowledge.

  18. A longitudinal analysis of alcohol outlet density and domestic violence.

    Science.gov (United States)

    Livingston, Michael

    2011-05-01

    A small number of studies have identified a positive relationship between alcohol outlet density and domestic violence. These studies have all been based on cross-sectional data and have been limited to the assessment of ecological correlations between outlet density and domestic violence rates. This study provides the first longitudinal examination of this relationship. Cross-sectional time-series using aggregated data from small areas. The relationships between alcohol outlet density and domestic violence were assessed over time using a fixed-effects model. Controls for the spatial autocorrelation of the data were included in the model. The study uses data for 186 postcodes from within the metropolitan area of Melbourne, Australia for the years 1996 to 2005. Alcohol outlet density measures for three different types of outlets (hotel/pub, packaged liquor, on-premise) were derived from liquor licensing records and domestic violence rates were calculated from police-recorded crime data, based on the victim's postcode. Alcohol outlet density was associated significantly with rates of domestic violence, over time. All three licence categories were positively associated with domestic violence rates, with small effects for general (pub) and on-premise licences and a large effect for packaged liquor licences. In Melbourne, the density of liquor licences is positively associated with rates of domestic violence over time. The effects were particularly large for packaged liquor outlets, suggesting a need for licensing policies that pay more attention to o off-premise alcohol availability. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  19. The Role at Rehabilitation in Treatment of Thoracic Outlet Syndrome

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hosseinian

    2003-01-01

    Full Text Available Objective: Thoracic outlet syndrome is a complex disorder caused by neurovascular irritation in the region of the thoracic outlet. The syndrome have been said to be mainly due to anomalous structures in the thoracic outlet, treatment for thoracic outlet syndrome varies among different institutions, and there has not been any standard program. In general conservative and surgical treatment can be do if necessary. Materials & Methods: The rehabilitation program consists of exercise and physiotherapy and brace designed to hold the posture in which thoracic outlet is enlarged. Exercise program was designed simple enough to be performed in the daily living or during work after minimal training and isometric exercises of Serratus anterior, Levator Scapulae and Erector Spinae muscles to be performed in one posture: flexion and elevation of scapular girdle and correction position of upper-thoracic spine. During 7 years, 131 cases of (T.O.S. were evaluated that 26 cases (20% have operated and 84 cases (64% have treated with conservative treatment and 21 cases (16% have been candidate for surgery but they didn't accepted. Results: All of the cases have treated with conservative treatment for four months. 84 cases responded well and no further treatment was needed. 47 cases were not satisfied with. The outcome of their treatment, that 26 cases have operated and 21 cases have not accepted the operation and continued the conservative treatment, they have had pain and slightly disability. 23 cases of operated group responded well and they have resumed to work, one case has had neuropraxia for about one year. Conclusion: Most cases of thoracic outlet syndrome (T.O.S. can be treated conservatively. Surgically treatment is indicated only in cases severe enough to make them disable to work. It is better all the patients undergo conservative treatment for at least four months then will decided for surgical treatment.

  20. A novel thermally driven rotor-vane/pressure-exchange ejector refrigeration system with environmental benefits and energy efficiency

    International Nuclear Information System (INIS)

    Hong, W.J.; Alhussan, Khaled; Zhang Hongfang; Garris, Charles A.

    2004-01-01

    The latest results of an ongoing coordinated experimental and computational program on the design and performance of a novel supersonic rotor-vane/pressure-exchange ejector for thermally driven ejector refrigeration systems are presented. For the supersonic rotor-vane/pressure-exchange ejector, careful management of the entropy rise through the oblique shocks and boundary layers is required for obtaining an advance in ejector performance. Since the invention of this new ejector is quite recent, understanding its aerodynamics, with the consequent optimization of performance, is in the formative stage. This paper shows how the supersonic aerodynamics is managed to provide the desirable flow induction characteristics through computational study and, in parallel, experimental results including flow visualization showing actual behavior with different-shaped rotor vanes. The importance of the existence of the tail part with a long expansion ramp, the sharp leading edge such as knife-edge, the proper height of leading edges, for the overall shape of rotor vane, were observed. Also the larger spin-angle rotor vane produces better flow induction and mixing between primary flow and secondary flow

  1. Hydraulic analysis of river training cross-vanes as part of post-restoration monitoring

    Directory of Open Access Journals (Sweden)

    T. A. Endreny

    2011-07-01

    Full Text Available River restoration design methods are incrementally improved by studying and learning from monitoring data in previous projects. In this paper we report post-restoration monitoring data and simulation analysis for a Natural Channel Design (NCD restoration project along 1600 m of the Batavia Kill (14 km2 watershed in the Catskill Mountains, NY. The restoration project was completed in 2002 with goals to reduce bank erosion and determine the efficacy of NCD approaches for restoring headwater streams in the Catskill Mountains, NY. The NCD approach used a reference-reach to determine channel form, empirical relations between the project site and reference site bankfull dimensions to size channel geometry, and hydraulic and sediment computations based on a bankfull (1.3 yr return interval discharge to test channel capacity and sediment stability. The NCD project included 12 cross-vanes and 48 j-hook vanes as river training structures along 19 meander bends to protect against bank erosion and maintain scour pools for fish habitat. Monitoring data collected from 2002 to 2004 were used to identify aggradation of pools in meander bends and below some structures. Aggradation in pools was attributed to the meandering riffle-pool channel trending toward step-pool morphology and cross-vane arms not concentrating flow in the center of the channel. The aggradation subsequently caused flow splitting and 4 partial point bar avulsions during a spring 2005 flood with a 25-yr return interval. Processing the pre-flood monitoring data with hydraulic analysis software provided clues the reach was unstable and preventative maintenance was needed. River restoration and monitoring teams should be trained in robust hydraulic analytical methods that help them extend project restoration goals and structure stability.

  2. Using marine sediment archives to reconstruct past outlet glacier variability

    DEFF Research Database (Denmark)

    Andresen, Camilla Snowman; Straneo, Fiamma; Ribergaard, Mads

    2013-01-01

    Ice-rafted debris in fjord sediment cores provides information about outlet glacier activity beyond the instrumental time period. It tells us that the Helheim Glacier, Greenland’s third most productive glacier, responds rapidly to short-term (3 to 10 years) climate changes....

  3. Gas pressure in bubble attached to tube circular outlet

    OpenAIRE

    Salonen, A; Gay, Cyprien; Maestro, A; Drenckhan, W; Rio, Emmanuelle

    2016-01-01

    In the present Supplementary notes to our work ``Arresting bubble coarsening: A two-bubble experiment to investigate grain growth in presence of surface elasticity'' (accepted in EPL), we derive the expression of the gas pressure inside a bubble located above and attached to the circular outlet of a vertical tube.

  4. Gastrojejunostomy for gastric outlet obstruction in patients with ...

    African Journals Online (AJOL)

    Sixty patients were discharged from hospital having resumed normal eating. Their median survival after surgery was 9 months. Conclusion. Gastrojejunostomy offers worthwhile palliation and may prolong survival in a significant group of patients with irresectable gastric carcinoma and gastric outlet obstruction. South African ...

  5. Supermarket and fast-food outlet exposure in Copenhagen

    DEFF Research Database (Denmark)

    Svastisalee, Chalida Mae; Jensen, Helene Nordahl; Glumer, Charlotte

    2011-01-01

    and neighbourhood-level socio-economic indicators. Food business addresses were obtained from commercial and public business locators and geocoded using a geographic information system for all neighbourhoods in the city of Copenhagen (n 400). The regression of counts of fast-food outlets and supermarkets v...

  6. Boundary conditions for free surface inlet and outlet problems

    KAUST Repository

    Taroni, M.; Breward, C. J. W.; Howell, P. D.; Oliver, J. M.

    2012-01-01

    We investigate and compare the boundary conditions that are to be applied to free-surface problems involving inlet and outlets of Newtonian fluid, typically found in coating processes. The flux of fluid is a priori known at an inlet, but unknown

  7. Publication Outlets for School Psychology Faculty: 2010 to 2015

    Science.gov (United States)

    Hulac, David; Johnson, Natalie D.; Ushijima, Shiho C.; Schneider, Maryia M.

    2016-01-01

    Many school psychology faculty are required to publish for purposes of retention and promotion. It is useful to have an understanding of the different outlets for scholarly publications. In the present study, we investigated the peer-reviewed journals in which school psychology faculty were published between 2010 and 2015, the number of articles…

  8. Predictive factors of bladder outlet obstruction following the tension ...

    African Journals Online (AJOL)

    H. Elghamrawi

    On the other hand, multivariate analysis indicated that Qmax was the only factor independently related to postoperative bladder outlet obstruction after TVTO (p = 0.002, odds ratio = 0.658, 95% CI for odds ratio 0.507–0.855). Discussion. Stress urinary incontinence defined as the involuntary loss of urine during increases in ...

  9. “Clavicular duplication causing thoracic outlet obstruction”: Unique ...

    African Journals Online (AJOL)

    A 22‑year‑old female student reported with features of neurogenic thoracic outlet syndrome mainly involving C8‑T1 components of the brachial plexus, seemingly originating from involvement in costo‑clavicular space. Radiograph of the shoulder revealed clavicular duplication. Neuro‑physiological studies corroborated the ...

  10. Velocities of antarctic outlet glaciers determined from sequential Landsat images

    Science.gov (United States)

    MacDonald, Thomas R.; Ferrigno, Jane G.; Williams, Richard S.; Lucchitta, Baerbel K.

    1989-01-01

    Approximately 91.0 percent of the volume of present-day glacier ice on Earth is in Antarctica; Greenland contains about another 8.3 percent of the volume. Thus, together, these two great ice sheets account for an estimated 99.3 percent of the total. Long-term changes in the volume of glacier ice on our planet are the result of global climate change. Because of the relationship of global ice volume to sea level (± 330 cubic kilometers of glacier ice equals ± 1 millimeter sea level), changes in the mass balance of the antarctic ice sheet are of particular importance.Whether the mass balance of the east and west antarctic ice sheets is positive or negative is not known. Estimates of mass input by total annual precipitation for the continent have been made from scattered meteorological observations (Swithinbank 1985). The magnitude of annual ablation of the ice sheet from calving of outlet glaciers and ice shelves is also not well known. Although the velocities of outlet glaciers can be determined from field measurements during the austral summer,the technique is costly, does not cover a complete annual cycle,and has been applied to just a few glaciers. To increase the number of outlet glaciers in Antarctica for which velocities have been determined and to provide additional data for under-standing the dynamics of the antarctic ice sheets and their response to global climate change, sequential Landsat image of several outlet glaciers were measured.

  11. Improvement of seawater booster pump outlet check valve

    International Nuclear Information System (INIS)

    Li Xuning; Du Yansong; Huang Huimin

    2010-01-01

    Conventional island seawater booster pump set of QNPC 310 MWe unit are very important in the whole circulating cooling system, and the integrate function of seawater booster pump outlet check valve is the foundation of steady operation of the seawater booster pump set. The article mainly introduce that through the analyses to the reason to the problem that the seawater booster pump outlet check valve of QNPC 310 MWe unit appeared in past years by our team, and considering the influence of operation condition and circumstance, the team improve the seawater booster pump outlet check valve from swing check valve to shuttle check valve which operate more appropriately in the system. By the test of continuous practice, we make further modification to the inner structure of shuttle check valve contrapuntally, and therefore we solve the problem in seawater booster pump outlet check valve fundamentally which has troubled the security of system operation in past years, so we realize the aim of technical improvement and ensure that the system operate in safety and stability. (authors)

  12. Report of an adult with double-outlet right ventricle

    International Nuclear Information System (INIS)

    Munera E, Ana G; Florez C, Marina; Delgado de B, Jorge A and others

    2001-01-01

    The case of a 22 -year- old woman with a diagnosis of congenital heart disease, N Y H A class I, who complaints palpitations. By echocardiography, angiography and magnetic resonance imaging a diagnosis of double-outlet right ventricle was done. She was intervened for correction, creating an interventricular tunnel connecting the left ventricle to the aorta through the ventricular septal defect

  13. Does availability of physical activity and food outlets differ by race and income? Findings from an enumeration study in a health disparate region.

    Science.gov (United States)

    Hill, Jennie L; Chau, Clarice; Luebbering, Candice R; Kolivras, Korine K; Zoellner, Jamie

    2012-09-06

    Low-income, ethnic/racial minorities and rural populations are at increased risk for obesity and related chronic health conditions when compared to white, urban and higher-socio-economic status (SES) peers. Recent systematic reviews highlight the influence of the built environment on obesity, yet very few of these studies consider rural areas or populations. Utilizing a CBPR process, this study advances community-driven causal models to address obesity by exploring the difference in resources for physical activity and food outlets by block group race and income in a small regional city that anchors a rural health disparate region. To guide this inquiry we hypothesized that lower income and racially diverse block groups would have fewer food outlets, including fewer grocery stores and fewer physical activity outlets. We further hypothesized that walkability, as defined by a computed walkability index, would be lower in the lower income block groups. Using census data and GIS, base maps of the region were created and block groups categorized by income and race. All food outlets and physical activity resources were enumerated and geocoded and a walkability index computed. Analyses included one-way MANOVA and spatial autocorrelation. In total, 49 stores, 160 restaurants and 79 physical activity outlets were enumerated. There were no differences in the number of outlets by block group income or race. Further, spatial analyses suggest that the distribution of outlets is dispersed across all block groups. Under the larger CPBR process, this enumeration study advances the causal models set forth by the community members to address obesity by providing an overview of the food and physical activity environment in this region. This data reflects the food and physical activity resources available to residents in the region and will aid many of the community-academic partners as they pursue intervention strategies targeting obesity.

  14. Does availability of physical activity and food outlets differ by race and income? Findings from an enumeration study in a health disparate region

    Directory of Open Access Journals (Sweden)

    Hill Jennie L

    2012-09-01

    Full Text Available Abstract Background Low-income, ethnic/racial minorities and rural populations are at increased risk for obesity and related chronic health conditions when compared to white, urban and higher-socio-economic status (SES peers. Recent systematic reviews highlight the influence of the built environment on obesity, yet very few of these studies consider rural areas or populations. Utilizing a CBPR process, this study advances community-driven causal models to address obesity by exploring the difference in resources for physical activity and food outlets by block group race and income in a small regional city that anchors a rural health disparate region. To guide this inquiry we hypothesized that lower income and racially diverse block groups would have fewer food outlets, including fewer grocery stores and fewer physical activity outlets. We further hypothesized that walkability, as defined by a computed walkability index, would be lower in the lower income block groups. Methods Using census data and GIS, base maps of the region were created and block groups categorized by income and race. All food outlets and physical activity resources were enumerated and geocoded and a walkability index computed. Analyses included one-way MANOVA and spatial autocorrelation. Results In total, 49 stores, 160 restaurants and 79 physical activity outlets were enumerated. There were no differences in the number of outlets by block group income or race. Further, spatial analyses suggest that the distribution of outlets is dispersed across all block groups. Conclusions Under the larger CPBR process, this enumeration study advances the causal models set forth by the community members to address obesity by providing an overview of the food and physical activity environment in this region. This data reflects the food and physical activity resources available to residents in the region and will aid many of the community-academic partners as they pursue intervention

  15. Endoscopic stenting versus operative gastrojejunostomy for malignant gastric outlet obstruction.

    Science.gov (United States)

    Chandrasegaram, Manju D; Eslick, Guy D; Mansfield, Clare O; Liem, Han; Richardson, Mark; Ahmed, Sulman; Cox, Michael R

    2012-02-01

    Malignant gastric outlet obstruction represents a terminal stage in pancreatic cancer. Between 5% and 25% of patients with pancreatic cancer ultimately experience malignant gastric outlet obstruction. The aim in palliating patients with malignant gastric outlet obstruction is to reestablish an oral intake by restoring gastrointestinal continuity. This ultimately improves their quality of life in the advanced stages of cancer. The main drawback to operative bypass is the high incidence of delayed gastric emptying, particularly in this group of patients with symptomatic obstruction. This study aimed to compare surgical gastrojejunostomy and endoscopic stenting in palliation of malignant gastric outlet obstruction, acknowledging the diversity and heterogeneity of patients with this presentation. This retrospective study investigated patients treated for malignant gastric outlet obstruction from December 1998 to November 2008 at Nepean Hospital, Sydney, Australia. Endoscopic duodenal stenting was performed under fluoroscopic guidance for placement of the stent. The operative patients underwent open surgical gastrojejunostomy. The outcomes assessed included time to diet, hospital length of stay (LOS), biliary drainage procedures, morbidity, and mortality. Of the 45 participants in this study, 26 underwent duodenal stenting and 19 had operative bypass. Comparing the stenting and operative patients, the median time to fluid intake was respectively 0 vs. 7 days (P < 0.001), and the time to intake of solids was 2 vs. 9 days (P = 0.004). The median total LOS was shorter in the stenting group (11 vs. 25 days; P < 0.001), as was the median postprocedure LOS (5 vs. 10 days; P = 0.07). Endoscopic stenting is preferable to operative gastrojejunostomy in terms of shorter LOS, faster return to fluids and solids, and reduced morbidity and in-hospital mortality for patients with a limited life span.

  16. Introduction on KPS's maintenance experience of the swirl vane assemblies of primary separators for SG model F in Korea

    International Nuclear Information System (INIS)

    Kim, Yong tae

    2003-01-01

    Recently, we had experienced to replace the Swirl Vane Assemblies of primary moisture separator for SG model F in Korea because of serious degradation (Thinning) in carbon steel swirl vane blades and carbon steel separator barrel wall adjacent to swirl vane blades. When the symptom was observed by us at the first time on the swirl vane assemblies, there were small or a bit clear erosion / or corrosion marks on the edge regions of the blades but within 3 cycles of operation, we found that those marks became holes which penetrated the most of swirl vane assemblies and even more seriously, some parts of the assemblies were worn-out. Therefore, we concluded that the speed of degradation would be very rapid and serious from the beginning stage. It had been assumed that these kinds of thinning problems would be due to FAC(Flow Accelerated Corrosion) because the plants having these problems are using a highly concentrated hydrazine for the water treatment of secondary side which lead to reduce the oxygen and pH in the water. What are more serious reasons will be that the swirl vane assemblies are very weak to FAC because they were made by a low concentrated chromium carbon steel and the assemblies would have to be under the operation conditions of the highly turbulent steam-water mixed fluid with the operating temperature of higher than 280 .deg. C. Potentially, the damaged swirl vane assemblies of the primary moisture separator may create bad influences for the plant operation because it may cause the rupture of SG Tubes and over-exceed fluid influx onto the turbine and etc. KPS had successfully performed the replacement of the degraded swirl vane assemblies through our own planning and preparation. This was the unique case in all over the world and I would like to introduce you about our unique repair experience to prepare an expected future situation as we see the similar problems in other model F SGs operating in Korea

  17. Mapping of the lateral flow field in typical subchannels of a support grid with vanes

    International Nuclear Information System (INIS)

    McClusky, Heather L.; Holloway, Mary V.; Conover, Timothy A.; Beasley, Donald E.; Conner, Michael E.; Smith III, L. David

    2003-01-01

    Lateral flow fields in four subchannels of a model rod bundle fuel assembly are measured using particle image velocimetry. Vanes (split-vane pairs) are located on the downstream edge of the support grids in the rod bundle fuel assembly and generate swirling flow. Measurements are acquired at a nominal Reynolds number of 28,000 and for seven streamwise locations ranging from 1.4 to 17.0 hydraulic diameters downstream of the grid. The streamwise development of the lateral flow field is divided into two regions based on the lateral flow structure. In Region I, multiple vortices are present in the flow field and vortex interactions occur. Either a single circular vortex or a hairpin shaped flow structure is formed in Region II. Lateral kinetic energy, maximum lateral velocity, centroid of vorticity, radial profiles of azimuthal velocity, and angular momentum are employed as measures of the streamwise development of the lateral flow field. The particle image velocimetry measurements of the present study are compared with laser doppler velocimetry measurements taken for the identical support grids and flow condition. (author)

  18. Proposal of a novel compact P-band magnetically insulated transmission line oscillator with inclined vanes

    Science.gov (United States)

    Zhang, Xiaoping; Dang, Fangchao; Li, Yangmei; Jin, Zhenxing

    2015-06-01

    In this paper, we present a novel compact P-band magnetically insulated transmission line oscillator (MILO) with specially inclined slow-wave-structure (SWS) vanes to decrease its total dimension and weight. The dispersion characteristics of the inclined SWS are investigated in detail and made comparisons with that of the traditional straight SWS. The results show that the inclined SWS is more advantageous in operating on a steady frequency in a wide voltage range and has a better asymmetric mode segregation and a relatively large band-gap between the TM00 and TM01 modes which are in favor of avoiding the asymmetric and transverse mode competition. Besides, the transverse dimension of the proposed novel inclined SWS with the same operation frequency is decreased by about 50%, and correspondingly the device volume shrinks remarkably to its 0.35 times. In particle-in-cell simulation, the electron bunching spokes are obviously formed in the inclined SWS, and a P-band high-power microwave with a power of 5.8 GW, frequency of 645 MHz, and efficiency of 17.2% is generated by the proposed device, which indicates the feasibility of the compact design with the inclined vanes at the P-band.

  19. Numerical Investigations of Unsteady Flow in a Centrifugal Pump with a Vaned Diffuser

    Directory of Open Access Journals (Sweden)

    Olivier Petit

    2013-01-01

    Full Text Available Computational fluid dynamics (CFD analyses were made to study the unsteady three-dimensional turbulence in the ERCOFTAC centrifugal pump test case. The simulations were carried out using the OpenFOAM Open Source CFD software. The test case consists of an unshrouded centrifugal impeller with seven blades and a radial vaned diffuser with 12 vanes. A large number of measurements are available in the radial gap between the impeller and the diffuse, making this case ideal for validating numerical methods. Results of steady and unsteady calculations of the flow in the pump are compared with the experimental ones, and four different turbulent models are analyzed. The steady simulation uses the frozen rotor concept, while the unsteady simulation uses a fully resolved sliding grid approach. The comparisons show that the unsteady numerical results accurately predict the unsteadiness of the flow, demonstrating the validity and applicability of that methodology for unsteady incompressible turbomachinery flow computations. The steady approach is less accurate, with an unphysical advection of the impeller wakes, but accurate enough for a crude approximation. The different turbulence models predict the flow at the same level of accuracy, with slightly different results.

  20. MATHEMATICAL MODEL FOR THE STUDY AND DESIGN OF A ROTARY-VANE GAS REFRIGERATION MACHINE

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2016-08-01

    Full Text Available This paper presents a mathematical model of calculating the main parameters the operating cycle, rotary-vane gas refrigerating machine that affect installation, machine control and working processes occurring in it at the specified criteria. A procedure and a graphical method for the rotary-vane gas refrigerating machine (RVGRM are proposed. A parametric study of the main geometric variables and temperature variables on the thermal behavior of the system is analyzed. The model considers polytrope index for the compression and expansion in the chamber. Graphs of the pressure and temperature in the chamber of the angle of rotation of the output shaft are received. The possibility of inclusion in the cycle regenerative heat exchanger is appreciated. The change of the coefficient of performance machine after turning the cycle regenerative heat exchanger is analyzed. It is shown that the installation of a regenerator RVGRM cycle results in increased COP more than 30%. The simulation results show that the proposed model can be used to design and optimize gas refrigerator Stirling.

  1. Cooling Strategies for Vane Leading Edges in a Syngas Environment Including Effects of Deposition and Turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Ames, Forrest [Univ. of North Dakota, Grand Forks, ND (United States); Bons, Jeffrey [Univ. of North Dakota, Grand Forks, ND (United States)

    2014-09-30

    The Department of Energy has goals to move land based gas turbine systems to alternate fuels including coal derived synthetic gas and hydrogen. Coal is the most abundant energy resource in the US and in the world and it is economically advantageous to develop power systems which can use coal. Integrated gasification combined cycles are (IGCC) expected to allow the clean use of coal derived fuels while improving the ability to capture and sequester carbon dioxide. These cycles will need to maintain or increase turbine entry temperatures to develop competitive efficiencies. The use of coal derived syngas introduces a range of potential contaminants into the hot section of the gas turbine including sulfur, iron, calcium, and various alkali metals. Depending on the effectiveness of the gas clean up processes, there exists significant likelihood that the remaining materials will become molten in the combustion process and potentially deposit on downstream turbine surfaces. Past evidence suggests that deposition will be a strong function of increasing temperature. Currently, even with the best gas cleanup processes a small level of particulate matter in the syngas is expected. Consequently, particulate deposition is expected to be an important consideration in the design of turbine components. The leading edge region of first stage vanes most often have higher deposition rates than other areas due to strong fluid acceleration and streamline curvature in the vicinity of the surface. This region remains one of the most difficult areas in a turbine nozzle to cool due to high inlet temperatures and only a small pressure ratio for cooling. The leading edge of a vane often has relatively high heat transfer coefficients and is often cooled using showerhead film cooling arrays. The throat of the first stage nozzle is another area where deposition potentially has a strongly adverse effect on turbine performance as this region meters the turbine inlet flow. Based on roughness

  2. Gastric Adenocarcinoma Presenting with Gastric Outlet Obstruction in a Child

    Directory of Open Access Journals (Sweden)

    Abdulrahman Al-Hussaini

    2014-01-01

    Full Text Available Gastric carcinoma is extremely rare in children representing only 0.05% of all gastrointestinal malignancies. Here, we report the first pediatric case of gastric cancer presenting with gastric outlet obstruction. Upper endoscopy revealed a markedly thickened antral mucosa occluding the pylorus and a clean base ulcer 1.5 cm × 2 cm at the lesser curvature of the stomach. The narrowed antrum and pylorus underwent balloon dilation, and biopsy from the antrum showed evidence of Helicobacter pylori gastritis. The biopsy taken from the edge of the gastric ulcer demonstrated signet-ring-cell type infiltrate consistent with gastric adenocarcinoma. At laparotomy, there were metastases to the liver, head of pancreas, and mesenteric lymph nodes. Therefore, the gastric carcinoma was deemed unresectable. The patient died few months after initiation of chemotherapy due to advanced malignancy. In conclusion, this case report underscores the possibility of gastric adenocarcinoma occurring in children and presenting with gastric outlet obstruction.

  3. Boundary conditions for free surface inlet and outlet problems

    KAUST Repository

    Taroni, M.

    2012-08-10

    We investigate and compare the boundary conditions that are to be applied to free-surface problems involving inlet and outlets of Newtonian fluid, typically found in coating processes. The flux of fluid is a priori known at an inlet, but unknown at an outlet, where it is governed by the local behaviour near the film-forming meniscus. In the limit of vanishing capillary number Ca it is well known that the flux scales with Ca 2/3, but this classical result is non-uniform as the contact angle approaches π. By examining this limit we find a solution that is uniformly valid for all contact angles. Furthermore, by considering the far-field behaviour of the free surface we show that there exists a critical capillary number above which the problem at an inlet becomes over-determined. The implications of this result for the modelling of coating flows are discussed. © 2012 Cambridge University Press.

  4. Simulation of water flows in multiple columns with small outlets

    International Nuclear Information System (INIS)

    Suh, Yong Kweon; Li, Zi Lu; Jeong, Jong Hyun; Lee, Jun Hee

    2006-01-01

    High-pressure die casting such as thixocasting and rheocasting is an effective process in the manufacturing automotive parts. Following the recent trend in the automotive manufacturing technologies, the product design subject to the die casting becomes more and more complex. Simultaneously the injection speed is also designed to be very high to establish a short cycle-time. Thus, the requirement of the die design becomes more demanding than ever before. In some cases the product's shape can have multiple slender manifolds. In such cases, design of the inlet and outlet parts of the die is very important in the whole manufacturing process. The main issues required for the qualified products are to attain gentle and uniform flow of the molten liquid within the passages of the die. To satisfy such issues, the inlet cylinder ('bed cylinder' in this paper) must be as large as possible and simultaneously the outlet opening at the end of each passage must be as small as possible. However these in turn obviously bring additional manufacturing costs caused by re-melting of the bed cylinder and increased power due to the small outlet-openings. The purpose of this paper is to develop effective simulation methods of calculation for fluid flows in multiple columns, which mimic the actual complex design, and to get some useful information which can give some contributions to the die-casting industry. We have used a commercial code CFX in the numerical simulation. The primary parameter involved is the size of the bed cylinder. We will show how the very small opening of the outlet can be treated with the aid of the porous model provided in the code. To check the validity of the numerical results we have also conducted a simple experiment by using water

  5. Infantile myofibromatosis: a most unusual cause of gastric outlet obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Rohrer, Kellie; Murphy, Robyn; Thresher, Caroline; Jacir, Nabil; Bergman, Kerry [Morristown Memorial Hospital, Department of Radiology, Morristown, NJ (United States)

    2005-08-01

    Non-bilious vomiting in the newborn is common. Etiologies include both surgical and medical conditions. Gastroesophageal reflux, soy or milk protein allergy, and prostaglandin-induced foveolar hyperplasia are among the medical causes. Surgical entities include gastric antral webs, pre-ampullary duodenal and pyloric atresia, and hypertrophic pyloric stenosis. We report the unique case of an 8-day-old girl who presented with gastric outlet obstruction secondary to infantile myofibromatosis. (orig.)

  6. Computer supervision of the core outlet sodium temperatures of FBTR

    International Nuclear Information System (INIS)

    Boopathy, C.

    1976-01-01

    Safety monitoring of the fast breeder test reactor at Kalpakkam (India) is achieved by a CDPS-on-line dual computer system which is dedicated to plant supervision. The on-line subsystem scans and supervises all the 170 core thermocouple signals every second. Organisation of the reactor core instruments, supervision of mean sodium outlet temperature and mean temperature drop across the core, detection of plugging of a fuel assembly are explained. (A.K.)

  7. Expiry of medicines in supply outlets in Uganda.

    Science.gov (United States)

    Nakyanzi, Josephine Katabaazi; Kitutu, Freddy Eric; Oria, Hussein; Kamba, Pakoyo Fadhiru

    2010-02-01

    The expiry of medicines in the supply chain is a serious threat to the already constrained access to medicines in developing countries. We investigated the extent of, and the main contributing factors to, expiry of medicines in medicine supply outlets in Kampala and Entebbe, Uganda. A cross-sectional survey of six public and 32 private medicine outlets was done using semi-structured questionnaires. The study area has 19 public medicine outlets (three non-profit wholesalers, 16 hospital stores/pharmacies), 123 private wholesale pharmacies and 173 retail pharmacies, equivalent to about 70% of the country's pharmaceutical businesses. Our findings indicate that medicines prone to expiry include those used for vertical programmes, donated medicines and those with a slow turnover. Awareness about the threat of expiry of medicines to the delivery of health services has increased. We have adapted training modules to emphasize management of medicine expiry for pharmacy students, pharmacists and other persons handling medicines. Our work has also generated more research interest on medicine expiry in Uganda. Even essential medicines expire in the supply chain in Uganda. Sound coordination is needed between public medicine wholesalers and their clients to harmonize procurement and consumption as well as with vertical programmes to prevent duplicate procurement. Additionally, national medicine regulatory authorities should enforce existing international guidelines to prevent dumping of donated medicine. Medicine selection and quantification should be matched with consumer tastes and prescribing habits. Lean supply and stock rotation should be considered.

  8. Female outlet obstruction constipation: assessment with MR defecography

    International Nuclear Information System (INIS)

    Li Min; Jiang Tao; Yang Xinqing; Peng Peng; Wang Wenchuan

    2010-01-01

    Objective: Using MR defecography to assess the morphological and functional anorectal anomalies related to female outlet obstruction constipation, and evaluate the joint disease of' anterior and mid pelvic. Methods: One hundred and seven female patients, aged 20 to 84 years (average, 55 years), were diagnosed as outlet obstruction constipation based on clinical symptoms and signs. They all received MR defecography in our institution. The high compliance homemade balloon was inserted into rectum to simulate stool. Then relevant measurements were obtained during rest, squeezing and straining, respectively. Results: In all the 107 cases, 70 (65.4%) presented rectocele on dynamic MRI; 28 (26.2%) presented anismus; 60 (56.1%) presented cystocele; 59 presented vaginal or cervical prolapse(55.1%); and, 54 (50.5%) presented descending perineum. In 85 females (79.4%) multiple disorders were detected, involving more than one pelvic compartment. Conclusion: MR defecography allowed to accurately evaluate the morphological and functional anorectal anomalies related to female outlet obstruction constipation, and the joint disease of anterior and mid pelvic. (authors)

  9. Antral hyperplastic polyp: A rare cause of gastric outlet obstruction.

    Science.gov (United States)

    Aydin, Ibrahim; Ozer, Ender; Rakici, Halil; Sehitoglu, Ibrahim; Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2014-01-01

    Gastric polyps are usually found incidentally during upper gastrointestinal endoscopic examinations. These polyps are generally benign, with hyperplasia being the most common. While gastric polyps are often asymptomatic, they can cause gastric outlet obstruction. A 64 years-old female patient presented to our polyclinic with a history of approximately 2 months of weakness, occasional early nausea, vomiting after meals and epigastric pain. A polypoid lesion of approximately 25mm in diameter was detected in the antral area of the stomach, which prolapsed through the pylorus into the duodenal bulbus, and subsequently caused gastric outlet obstruction, as revealed by upper gastrointestinal endoscopy of the patient. The polyp was retrieved from the pyloric canal into the stomach with the aid of a tripod, and snare polypectomy was performed. Currently, widespread use of endoscopy has led to an increase in the frequency of detecting hyperplastic polyps. While most gastric polyps are asymptomatic, they can cause iron deficiency anemia, acute pancreatitis and more commonly, gastric outlet obstruction because of their antral location. Although there are no precise principles in the treatment of asymptomatic polyps, polyps >5mm should be removed due to the possibility of malignant transformation. According to the medical evidence, polypectomy is required for gastric hyperplastic polyps because of the risks of complication and malignancy. These cases can be successfully treated endoscopically. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. 16 CFR Appendix E to Part 436 - Sample Item 20(4) Table-Status of Company-Owned Outlets

    Science.gov (United States)

    2010-01-01

    ... RULES DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. E Appendix E to Part... 5Outlets Reacquired From Franchisees Column 6Outlets Closed Column 7Outlets Sold to Franchisees Column...

  11. Effect of long time service exposure on microstructure and mechanical properties of gas turbine vanes made of IN939 alloy

    International Nuclear Information System (INIS)

    Jahangiri, M.R.; Abedini, M.

    2014-01-01

    Highlights: • Microstructure of service-exposed turbine vanes made of IN939 was investigated. • Mechanical properties of service-exposed alloy were also investigated. • Formation of M 23 C 6 films on GBs and degeneration of MCs are microstructural changes. • Despite its thermodynamic favorability, σ phase is not observed in microstructure. • Microstructural changes lead to a loss in tensile ductility and creep life. - Abstract: In the present study, the effects of long-term service exposure have been investigated on microstructure and mechanical properties of gas turbine vanes made of IN939 superalloy. The major microstructural changes for the investigated service-exposed vanes include the formation of continuous grain boundary carbides and the transformation (degeneration) of MC carbides located at the grain boundaries. The brittle σ phase, which is predicted to be stable on the basis of thermodynamic calculations, is not observed in the microstructure of service-exposed vanes. The microstructural changes during service lead to a loss in room temperature ductility as well as in creep properties of the alloy

  12. Preliminary Investigation on Turbulent Flow in Tight-lattice Rod Bundle with Twist-mixing Vane Spacer Grid

    International Nuclear Information System (INIS)

    Lee, Chiyoung; Kwack, Youngkyun; Park, Juyong; Shin, Changhwan; In, Wangkee

    2013-01-01

    Our research group has investigated the effect of P/D difference on the behavior of turbulent rod bundle flow without the mixing vane spacer grid, using PIV (Particle Image Velocimetry) and MIR (Matching Index of Refraction) techniques for tight lattice fuel rod bundle application. In this work, using the tight-lattice rod bundle with a twist-mixing vane spacer grid, the turbulent rod bundle flow is preliminarily examined to validate the PIV measurement and CFD (Computational Fluid Dynamics) simulation. The turbulent flow in the tight-lattice rod bundle with a twist-mixing vane spacer grid was preliminarily examined to validate the PIV measurement and CFD simulation. Both were in agreement with each other within a reasonable degree of accuracy. Using PIV measurement and CFD simulation tested in this work, the detailed investigations on the behavior of turbulent rod bundle flow with the twist-mixing vane spacer grid will be performed at various conditions, and reported in the near future

  13. 2.5 MeV CW 4-vane RFQ accelerator design for BNCT applications

    Science.gov (United States)

    Zhu, Xiaowen; Wang, Hu; Lu, Yuanrong; Wang, Zhi; Zhu, Kun; Zou, Yubin; Guo, Zhiyu

    2018-03-01

    Boron Neutron Capture Therapy (BNCT) promises a bright future in cancer therapy for its highly selective destruction of cancer cells, using the 10B +n→7Li +4 He reaction. It offers a more satisfactory therapeutic effect than traditional methods for the treatment of malignant brain tumors, head and neck cancer, melanoma, liver cancer and so on. A CW 4-vane RFQ, operating at 162.5 MHz, provides acceleration of a 20 mA proton beam to 2.5 MeV, bombarding a liquid lithium target for neutron production with a soft neutron energy spectrum. The fast neutron yield is about 1.73×1013 n/s. We preliminarily develop and optimize a beam shaping assembly design for the 7Li(p, n)7Be reaction with a 2.5 MeV proton beam. The epithermal neutron flux simulated at the beam port will reach up to 1 . 575 ×109 n/s/cm2. The beam dynamics design, simulation and benchmark for 2.5 MeV BNCT RFQ have been performed with both ParmteqM (V3.05) and Toutatis, with a transmission efficiency higher than 99.6% at 20 mA. To ease the thermal management in the CW RFQ operation, we adopt a modest inter-vane voltage design (U = 65 kV), though this does increase the accelerator length (reaching 5.2 m). Using the well-developed 3D electromagnetic codes, CST MWS and ANSYS HFSS, we are able to deal with the complexity of the BNCT RFQ, taking the contribution of each component in the RF volume into consideration. This allows us to optimize the longitudinal field distribution in a full-length model. Also, the parametric modeling technique is of great benefit to extensive modifications and simulations. In addition, the resonant frequency tuning of this RFQ is studied, giving the tuning sensitivities of vane channel and wall channel as -16.3 kHz/°C and 12.4 kHz/°C, respectively. Finally, both the multipacting level of this RFQ and multipacting suppressing in the coaxial coupler are investigated.

  14. Investigating the thermal hydraulic performance of spacer grid with mixing vanes using STAR-CCM+ and MATRA

    International Nuclear Information System (INIS)

    Agbodemegbe, V. Y.

    2014-07-01

    Enhancement of heat transfer for flow through rod bundles is linked to the extent and sustainability of mixing in the flow geometry. Spacer grids used as support for rod bundles in nuclear reactors, when attached with ditferent designs of mixing vanes promote turbulent mixing by inducing swirl or forced lateral convection that improves mixing within or between sub-channels. The improved turbulent mixing raises the margin of the onset of critical heat flux in light water reactors (LWR) and also ensures a higher fuel cycle economy. To optimize design of mixing vanes and performance of spacer grids with mixing vanes, computational fluid dynamic simulations arc carried out on new designs and validated experimentally prior to industrial application. In the present study, computational fluid dynamic simulation using STAR-CCM+ and sub-channel analysis with MATRA were performed for flow of water through a 5 X 5 rod bundle geometry for which the rod to rod pitch to diameter ratio was 1.33 and the wall to rod pitch to diameter ratio was 0.74. The two layer k-epsilon turbulence model with an all- y + automatic wall treatment function in STAR-CCM+ were adopted for an isothermal single phase flow through the geometry with imposed cyclic periodic and non-cyclic periodic interface boundary conditions. The objective was to primarily investigate the detail flow behavior in rod bundle in the presence of spacer grids with and without attached mixing vanes. Furthermore, the present study also investigated the extent of turbulent mixing and lateral mass flux induced by the mixing vanes through comparative analysis of parametric trends for spacer grid with and without mixing vanes. New models and empirical correlations for describing the mixing vanes effects were also developed. These semi-empirical correlations improved the prediction for lateral mass flux due to turbulence, fraction of flow diverted through gaps and cross-flow resistance coefficients. Validation of simulation results

  15. Lateral Flow Field Behavior Downstream of Mixing Vanes In a Simulated Nuclear Fuel Rod Bundle

    International Nuclear Information System (INIS)

    Conner, Michael E.; Smith, L. David III; Holloway, Mary V.; Beasley, Donald E.

    2004-01-01

    To assess the fuel assembly performance of PWR nuclear fuel assemblies, average subchannel flow values are used in design analyses. However, for this highly complex flow, it is known that local conditions around fuel rods vary dependent upon the location of the fuel rod in the fuel assembly and upon the support grid design that maintains the fuel rod pitch. To investigate the local flow in a simulated nuclear fuel rod bundle, a testing technique has been employed to measure the lateral flow field in a 5 x 5 rod bundle. Particle Image Velocimetry was used to measure the lateral flow field downstream of a support grid with mixing vanes for four unique subchannels in the 5 x 5 bundle. The dominant lateral flow structures for each subchannel are compared in this paper including the decay of these flow structures. (authors)

  16. Active Flow Control in a Radial Vaned Diffuser for Surge Margin Improvement: A Multislot Suction Strategy

    Directory of Open Access Journals (Sweden)

    Aurélien Marsan

    2017-01-01

    Full Text Available This work is the final step of a research project that aims at evaluating the possibility of delaying the surge of a centrifugal compressor stage using a boundary-layer suction technique. It is based on Reynolds-Averaged Navier-Stokes numerical simulations. Boundary-layer suction is applied within the radial vaned diffuser. Previous work has shown the necessity to take into account the unsteady behavior of the flow when designing the active flow control technique. In this paper, a multislot strategy is designed according to the characteristics of the unsteady pressure field. Its implementation results in a significant increase of the stable operating range predicted by the unsteady RANS numerical model. A hub-corner separation still exists further downstream in the diffuser passage but does not compromise the stability of the compressor stage.

  17. Scaling laws for gas–liquid flow in swirl vane separators

    International Nuclear Information System (INIS)

    Liu, Li; Bai, Bofeng

    2016-01-01

    Highlights: • Model for swirl vane separator performance is established with similarity criteria. • Scaling laws are developed to correlate downscale test with prototype separator. • Effects of key similarity criteria on separation performance are studied. • The vital role of droplet size distribution on separation performance is discussed. - Abstract: Laboratory tests on gas–liquid flow in swirl vane separators are usually carried out to help establish an experimental database for separator design and performance improvement. Such model tests are generally performed in the reduced scale and not on the actual working conditions. Though great efficiency is often obtainable in the reduced model, the performance of the full-sized prototype usually cannot be well predicted. To design downscale model tests and apply the experimental results to predict the prototype, a general relationship to correlate them is required. In this paper, the relation of the similitude-criterion concerning the pressure loss is presented by using the dimensionless analysis, and mathematical models for critical droplet diameter, grade efficiency and overall separation efficiency are established by analyzing the features of the droplet trajectory in gas swirling flow field. The essential similarity criteria accounting for pressure loss and separation efficiency are obtained, respectively. On this basis, the scaling laws which enable a comparison between the reduced model and the full-sized prototype under similar conditions are also developed. It is found that the overall separation efficiency is significantly affected by the size distribution of the small droplets, especially when the mean diameter is smaller than the critical droplet diameter.

  18. Availability of limited service food outlets surrounding schools in British Columbia.

    Science.gov (United States)

    Black, Jennifer L; Day, Meghan

    2012-06-05

    The purpose of this study was to provide a descriptive profile of the availability of limited service food outlets surrounding public schools in British Columbia, Canada. Data from the 2010 Canadian Business Data Files were used to identify limited service food outlets including fast food outlets, beverage and snack food stores, delis and convenience stores. The number of food outlets within 800 metres of 1,392 public schools and the distance from schools to the nearest food outlets were assessed. Multivariate regression models examined the associations between food outlet availability and school-level characteristics. In 2010, over half of the public schools in BC (54%) were located within a 10-12 minute walk from at least one limited service food outlet. The median closest distance to a food outlet was just over 1 km (1016 m). Schools comprised of students living in densely populated urban neighbourhoods and neighbourhoods characterized by lower socio-economic status were more likely to have access to limited service food outlets within walking distance. After adjusting for school-level median family income and population density, larger schools had higher odds of exposure to food vendors compared to schools with fewer students. The availability of and proximity to limited service food outlets vary widely across schools in British Columbia and school-level characteristics are significantly associated with food outlet availability. Additional research is needed to understand how food environment exposures inside and surrounding schools impact students' attitudes, food choices and dietary quality.

  19. PPOOLEX experiments with a modified blowdown pipe outlet

    International Nuclear Information System (INIS)

    Laine, J.; Puustinen, M.; Raesaenen, A.

    2009-08-01

    This report summarizes the results of the experiments with a modified blowdown pipe outlet carried out with the PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through a vertical DN200 blowdown pipe to the condensation pool. Four reference experiments with a straight pipe and ten with the Forsmark type collar were carried out. The main purpose of the experiment series was to study the effect of a blowdown pipe outlet collar design on loads caused by chugging phenomena (rapid condensation) while steam is discharged into the condensation pool. The PPOOLEX test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. During the experiments the initial temperature level of the condensation pool water was either 20-25 or 50-55 deg. C. The steam flow rate varied from 400 to 1200 g/s and the temperature of incoming steam from 142 to 185 deg. C. In the experiments with 20-25 deg. C pool water, even 10 times higher pressure pulses were measured inside the blowdown pipe in the case of the straight pipe than with the collar. In this respect, the collar design worked as planned and removed the high pressure spikes from the blowdown pipe. Meanwhile, there seemed to be no suppressing effect on the loads due to the collar in the pool side in this temperature range. Registered loads in the pool were approximately in the same range (or even a little higher) with the collar as with the straight pipe. In the experiments with 50-55 deg. C pool water no high pressure pulses were measured inside the blowdown pipe either with the straight pipe or with the collar. In this case, more of the suppressing effect is probably due to the warmer pool water than due to the modified pipe outlet. It has been observed already in the earlier experiments with a straight pipe in the POOLEX and PPOOLEX facilities that warm pool water has a diminishing effect on

  20. Plasmatron with expanding channel of outlet electrode and its applications

    International Nuclear Information System (INIS)

    Chinnov, V.F.; Isakajev, E.Kh.; Ivanov, P.P.; Sinkevich, O.A.; Tyuftyaev, A.S.

    2000-01-01

    A serious industrial application is found for the plasmatron with expanding channel of outlet electrode - hardening and nitriding surface treatment of railway wheels. Several plasma installations are under operation at the engine houses of Moscow Railways. More than 12 000 wheel sets have been treated up to now. Results are evident: wheel life doubles due to plasma treatment. The plasmatron developed essentially in an empiric way is now under heavy investigation both theoretically and experimentally. High precision measurements of nitrogen emission spectra are expected to be used directly for accurate calculation of radiation heat loss term in a quasi-one dimensional flow code. (Authors)

  1. Measurement of unsteady airflow velocity at nozzle outlet

    Science.gov (United States)

    Pyszko, René; Machů, Mário

    2017-09-01

    The paper deals with a method of measuring and evaluating the cooling air flow velocity at the outlet of the flat nozzle for cooling a rolled steel product. The selected properties of the Prandtl and Pitot sensing tubes were measured and compared. A Pitot tube was used for operational measurements of unsteady dynamic pressure of the air flowing from nozzles to abtain the flow velocity. The article also discusses the effects of air temperature, pressure and relative air humidity on air density, as well as the influence of dynamic pressure filtering on the error of averaged velocity.

  2. PPOOLEX experiments with a modified blowdown pipe outlet

    Energy Technology Data Exchange (ETDEWEB)

    Laine, J.; Puustinen, M.; Raesaenen, A. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2009-08-15

    This report summarizes the results of the experiments with a modified blowdown pipe outlet carried out with the PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through a vertical DN200 blowdown pipe to the condensation pool. Four reference experiments with a straight pipe and ten with the Forsmark type collar were carried out. The main purpose of the experiment series was to study the effect of a blowdown pipe outlet collar design on loads caused by chugging phenomena (rapid condensation) while steam is discharged into the condensation pool. The PPOOLEX test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. During the experiments the initial temperature level of the condensation pool water was either 20-25 or 50-55 deg. C. The steam flow rate varied from 400 to 1200 g/s and the temperature of incoming steam from 142 to 185 deg. C. In the experiments with 20-25 deg. C pool water, even 10 times higher pressure pulses were measured inside the blowdown pipe in the case of the straight pipe than with the collar. In this respect, the collar design worked as planned and removed the high pressure spikes from the blowdown pipe. Meanwhile, there seemed to be no suppressing effect on the loads due to the collar in the pool side in this temperature range. Registered loads in the pool were approximately in the same range (or even a little higher) with the collar as with the straight pipe. In the experiments with 50-55 deg. C pool water no high pressure pulses were measured inside the blowdown pipe either with the straight pipe or with the collar. In this case, more of the suppressing effect is probably due to the warmer pool water than due to the modified pipe outlet. It has been observed already in the earlier experiments with a straight pipe in the POOLEX and PPOOLEX facilities that warm pool water has a diminishing effect on

  3. Methodological Approaches to Locating Outlets of the Franchise Retail Network

    Directory of Open Access Journals (Sweden)

    Grygorenko Tetyana M.

    2016-08-01

    Full Text Available Methodical approaches to selecting strategic areas of managing the future location of franchise retail network outlets are presented. The main stages in the assessment of strategic areas of managing the future location of franchise retail network outlets have been determined and the evaluation criteria have been suggested. Since such selection requires consideration of a variety of indicators and directions of the assessment, the author proposes a scale of evaluation, which allows generalizing and organizing the research data and calculations of the previous stages of the analysis. The most important criteria and sequence of the selection of the potential franchisees for the franchise retail network have been identified, the technique for their evaluation has been proposed. The use of the suggested methodological approaches will allow the franchiser making sound decisions on the selection of potential target markets, minimizing expenditures of time and efforts on the selection of franchisees and hence optimizing the process of development of the franchise retail network, which will contribute to the formation of its structure.

  4. Prolapsing Gastric Polyp Causing Intermittent Gastric Outlet Obstruction.

    Science.gov (United States)

    Kosai, Nik Ritza; Gendeh, Hardip Singh; Norfaezan, Abdul Rashid; Razman, Jamin; Sutton, Paul Anthony; Das, Srijit

    2015-06-01

    Gastric polyps are often an incidental finding on upper gastrointestinal endoscopy, with an incidence up to 5%. The majority of gastric polyps are asymptomatic, occurring secondary to inflammation. Prior reviews discussed Helicobacter pylori (H pylori)-associated singular gastric polyposis; however, we present a rare and unusual case of recurrent multiple benign gastric polyposis post H pylori eradication resulting in intermittent gastric outlet obstruction. A 70-year-old independent male, Chinese in ethnicity, with a background of diabetes mellitus, hypertension, and a simple renal cyst presented with a combination of melena, anemia, and intermittent vomiting of partially digested food after meals. Initial gastroscopy was positive for H pylori; thus he was treated with H pylori eradication and proton pump inhibitors. Serial gastroscopy demonstrated multiple sessile gastric antral polyps, the largest measuring 4 cm. Histopathologic examination confirmed a benign hyperplastic lesion. Computed tomography identified a pyloric mass with absent surrounding infiltration or metastasis. A distal gastrectomy was performed, whereby multiple small pyloric polyps were found, the largest prolapsing into the pyloric opening, thus explaining the intermittent nature of gastric outlet obstruction. Such polyps often develop from gastric ulcers and, if left untreated, may undergo neoplasia to form malignant cells. A distal gastrectomy was an effective choice of treatment, taking into account the polyp size, quantity, and potential for malignancy as opposed to an endoscopic approach, which may not guarantee a complete removal of safer margins and depth. Therefore, surgical excision is favorable for multiple large gastric polyps with risk of malignancy.

  5. Antral hyperplastic polyp causing intermittent gastric outlet obstruction: Case report

    Directory of Open Access Journals (Sweden)

    Kurtkaya-Yapicier Ozlem

    2003-06-01

    Full Text Available Abstract Background Hyperplastic polyps are the most common polypoid lesions of the stomach. Rarely, they cause gastric outlet obstruction by prolapsing through the pyloric channel, when they arise in the prepyloric antrum. Case presentation A 62-year-old woman presented with intermittent nausea and vomiting of 4 months duration. Upper gastrointestinal endoscopy revealed a 30 mm prepyloric sessile polyp causing intermittent gastric outlet obstruction. Following submucosal injection of diluted adrenaline solution, the polyp was removed with a snare. Multiple biopsies were taken from the greater curvature of the antrum and the corpus. Rapid urease test for Helicobacter pylori yielded a negative result. Histopathologic examination showed a hyperplastic polyp without any evidence of malignancy. Biopsies of the antrum and the corpus revealed gastritis with neither atrophic changes nor Helicobacter pylori infection. Follow-up endoscopy after a 12-week course of proton pomp inhibitor therapy showed a complete healing without any remnant tissue at the polypectomy site. The patient has been symptom-free during 8 months of follow-up. Conclusions Symptomatic gastric polyps should be removed preferentially when they are detected at the initial diagnostic endoscopy. Polypectomy not only provides tissue to determine the exact histopathologic type of the polyp, but also achieves radical treatment.

  6. A Longitudinal Analysis of Cigarette Prices in Military Retail Outlets

    Science.gov (United States)

    Haddock, Christopher Keith; Hyder, Melissa L.; Poston, Walker S. C.; Jahnke, Sara A.; Williams, Larry N.; Lando, Harry

    2014-01-01

    Objectives. We conducted a longitudinal assessment of tobacco pricing in military retail outlets, including trends within each service branch. Methods. We determined the price of a single pack of Marlboro Red cigarettes at military retail stores located in the continental United States, Alaska, and Hawaii and at their nearest Walmarts in spring 2011 and 2013 (n = 128 for pairs available at both assessments). Results. The average difference between cigarettes sold in military retail outlets and Walmarts decreased from 24.5% in 2011 to 12.5% in 2013. The decrease was partially attributable to significant price decreases at Walmarts. The largest increases in cigarette prices occurred on naval installations. Potential savings at stores on several installations remained substantial in 2013; the largest approached $6 per pack. Stores on 17 military installations decreased cigarette prices during the study period. Conclusions. Tobacco can be purchased in military retail stores at substantial savings over civilian stores. If tobacco pricing is to cease to be an incentive for use among personnel, a revised military tobacco pricing policy is needed. PMID:24524503

  7. Enhancing sediment distribution at the vicinity of power plant intakes using double rows of vanes and groins (Case study: New tebbin power plant

    Directory of Open Access Journals (Sweden)

    Sayed Mahgoub

    2013-12-01

    The study results showed that, in case of vanes absence, sediments with rates 1–2 m3/week were stuck within the sediment trap under the winter conditions. Also, the results indicated that the submerged vanes play an important role in preventing the sediment intrusion. Also, it was clear that using groins might lead to enhancing the sediment distribution at the intake vicinity.

  8. Loss model for off-design performance analysis of radial turbines with pivoting-vane, variable-area stators

    Science.gov (United States)

    Meitner, P. L.; Glassman, A. J.

    1980-01-01

    An off-design performance loss model for a radial turbine with pivoting, variable-area stators is developed through a combination of analytical modeling and experimental data analysis. A viscous loss model is used for the variation in stator loss with setting angle, and stator vane end-clearance leakage effects are predicted by a clearance flow model. The variation of rotor loss coefficient with stator setting angle is obtained by means of an analytical matching of experimental data for a rotor that was tested with six stators, having throat areas from 20 to 144% of the design area. An incidence loss model is selected to obtain best agreement with experimental data. The stator vane end-clearance leakage model predicts increasing mass flow and decreasing efficiency as a result of end-clearances, with changes becoming significantly larger with decreasing stator area.

  9. Preliminary results for validation of Computational Fluid Dynamics for prediction of flow through a split vane spacer grid

    International Nuclear Information System (INIS)

    Rashkovan, A.; Novog, D.R.

    2012-01-01

    This paper presents the results of the CFD simulations of turbulent flow past spacer grid with mixing vanes. This study summarizes the first stage of the ongoing numerical blind exercise organized by OECD-NEA. McMaster University along with other participants plan to submit a numerical prediction of the detailed flow field and turbulence characteristics of the flow past 5x5 rod bundle with a spacer grid equipped with two types of mixing vanes. The results will be compared with blind experimental measurements performed in Korea. Due to the fact that a number of the modeling strategies are suggested in literature for such types of flows, we have performed a series of tests to assess the mesh requirements, flow steadiness, turbulence modeling and wall treatment effects. Results of these studies are reported in the present paper. (author)

  10. A new low threshold bi-directional wind vane and its potential impact on unplanned atmospheric release prediction

    International Nuclear Information System (INIS)

    Parker, M.J.

    1996-01-01

    At the Savannah River Site, the Environmental Transport Group (ETG) maintains and develops a comprehensive meteorological monitoring program which employs bi-directional wind vanes (bivanes) for the measurement of horizontal and vertical wind direction and turbulence. Wind data collected near and below instrument starting thresholds under stable nighttime conditions with these bivanes can result in artificially large standard deviations of horizontal wind direction (σA). In one hypothetical case, downwind concentrations could be underestimated by a factor of 40 by using artificially high σA data in a Gaussian dispersion model. In an effort to improve low wind speed measurements of wind direction, a Cooperative Research and Development Agreement (CRADA) between Met One Instruments and the Westinghouse Savannah River Company (WSRC) has been created to improve the dynamic performance of the Met One Model 1585 Bi-Directional Wind Vane

  11. Laboratory services series: an electrical outlet and corded equipment inspection program

    International Nuclear Information System (INIS)

    Davis, E.A.

    1976-04-01

    A research and development laboratory has thousands of electrical outlets providing power to laboratories, offices, shops, and service areas. These outlets provide power for a wide variety of portable equipment and tools that are equipped with cord and plug. Electric safety requires a periodic check of outlet grounding capability and continuing inspection and repair of corded equipment. Personnel, equipment, reports, procedures, and schedule requirements are reported

  12. Spatial accessibility to physical activity facilities and to food outlets and overweight in French youth.

    Science.gov (United States)

    Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C

    2012-07-01

    Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Cross-sectional study. 3293 students, aged 12 ± 0.6 years, randomly selected from eastern France middle schools. Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25-2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20-2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). These results indicate that disparities in spatial accessibility to PA facilities and to general food outlets may amplify the risk of overweight in socio

  13. Bacteriological Analysis and Hygine Level of Food Outlets within Rufus Giwa Polytechnic, Owo, Ondo State, Nigeria.

    OpenAIRE

    Ibrahim TA; Akenroye OM; Osabiya OJ

    2013-01-01

    The bacteriological quality of three major food outlets in Rufus Giwa Polytechnic, Owo, was assessed using standard bacteriological methods. Swabs of hands of food vendors, table and plates in these outlets were assessed for total bacterial count, total coliform count and total E. coli count. A total of 789 bacterial colonies were isolated from hands of food handlers, tables and plates used for eating in the outlets. Eleven genera of bacteria were isolated and identified, they were; klebsiell...

  14. Availability of healthier options in traditional and nontraditional rural fast-food outlets

    OpenAIRE

    Creel, Jennifer S; Sharkey, Joseph R; McIntosh, Alex; Anding, Jenna; Huber, J Charles

    2008-01-01

    Abstract Background Food prepared away from home has become increasingly popular to U.S. families, and may contribute to obesity. Sales have been dominated by fast food outlets, where meals are purchased for dining away from home or in the home. Although national chain affiliated fast-food outlets are considered the main source for fast food, fast foods are increasingly available in convenience stores and supermarkets/grocery stores. In rural areas, these nontraditional fast-food outlets may ...

  15. A GIS Application to Explore Postal Retail Outlet Locations

    Directory of Open Access Journals (Sweden)

    Nikola Trubint

    2012-03-01

    Full Text Available The use of GIS in solving a wide variety of problems in postal operations is expanding. This approach provides the development and usage of new methods in spatial data analysis, as support in achieving a better quality of the decision-making process. The use of location analysis model based on GIS software is implemented in solving the Belgrade postal retail outlet problem. One of the most important experiences of model implementation is that the local environmental conditions have a significant impact on strategic as well as operational approach. A portion of the material included in the paper has resulted from the Serbian PTT and CPC (Canada Post Corporation joint project Location Analysis.

  16. Validation of turbulence models for LMFBR outlet plenum flows

    International Nuclear Information System (INIS)

    Chen, Y.B.; Golay, M.W.

    1977-01-01

    Small scale experiments involving water flows are used to provide mean flow and turbulence field data for LMFBR outlet plenum flows. Measurements are performed at Reynolds number (Re) values of 33000 and 70000 in a 1/15 - scale FFTF geometry and at Re = 35000 in a 3/80-scale CRBR geometry. The experimental behavior is predicted using two different two-equation turbulence model computer programs, TEACH-T and VARR-II. It is found that the qualitative nature of the flow field within the plenum depends strongly upon the distribution of the mean inlet flow field, importantly also upon the degree of inlet turbulence, and also upon the turbulent momentum exchange model used in the calculations. In the FFTF geometry, the TEACH-T predictions agree well with the experiments. 7 refs

  17. Supraclavicular scalenectomy for thoracic outlet syndrome--functional outcomes assessed using the DASH scoring system.

    LENUS (Irish Health Repository)

    Glynn, Ronan W

    2012-02-01

    To evaluate supraclavicular scalenectomy ± cervical rib excision for thoracic outlet syndrome (TOS), employing Disability of Arm, Shoulder, and Hand (DASH) scoring for functional assessment post-decompression.

  18. Fractionating power and outlet stream polydispersity in asymmetrical flow field-flow fractionation. Part I: isocratic operation.

    Science.gov (United States)

    Williams, P Stephen

    2016-05-01

    Asymmetrical flow field-flow fractionation (As-FlFFF) has become the most commonly used of the field-flow fractionation techniques. However, because of the interdependence of the channel flow and the cross flow through the accumulation wall, it is the most difficult of the techniques to optimize, particularly for programmed cross flow operation. For the analysis of polydisperse samples, the optimization should ideally be guided by the predicted fractionating power. Many experimentalists, however, neglect fractionating power and rely on light scattering detection simply to confirm apparent selectivity across the breadth of the eluted peak. The size information returned by the light scattering software is assumed to dispense with any reliance on theory to predict retention, and any departure of theoretical predictions from experimental observations is therefore considered of no importance. Separation depends on efficiency as well as selectivity, however, and efficiency can be a strong function of retention. The fractionation of a polydisperse sample by field-flow fractionation never provides a perfectly separated series of monodisperse fractions at the channel outlet. The outlet stream has some residual polydispersity, and it will be shown in this manuscript that the residual polydispersity is inversely related to the fractionating power. Due to the strong dependence of light scattering intensity and its angular distribution on the size of the scattering species, the outlet polydispersity must be minimized if reliable size data are to be obtained from the light scattering detector signal. It is shown that light scattering detection should be used with careful control of fractionating power to obtain optimized analysis of polydisperse samples. Part I is concerned with isocratic operation of As-FlFFF, and part II with programmed operation.

  19. Hydraulics and pneumatics a technician's and engineer's guide

    CERN Document Server

    Parr, Andrew

    1991-01-01

    Hydraulics and Pneumatics: A Technician's and Engineer's Guide provides an introduction to the components and operation of a hydraulic or pneumatic system. This book discusses the main advantages and disadvantages of pneumatic or hydraulic systems.Organized into eight chapters, this book begins with an overview of industrial prime movers. This text then examines the three different types of positive displacement pump used in hydraulic systems, namely, gear pumps, vane pumps, and piston pumps. Other chapters consider the pressure in a hydraulic system, which can be quickly and easily controlled

  20. Experimental evidence of the thermal effect of lubricating oil sprayed in sliding-vane air compressors

    Directory of Open Access Journals (Sweden)

    Gianluca Valenti

    2014-11-01

    Full Text Available A way to increase the efficiency of positive-displacement air compressor is spraying the lube oil to exploit it not only as lubricating and sealing agent but also as thermal ballast. This work seeks the experimental evidence in sliding-vane compressors by measuring the air standard volume flow rate and the electrical power input of three diverse configurations. The first configuration, taken as the reference, employs a conventional injection system comprising calibrated straight orifices. The other two, referred to as advanced, adopt smaller orifices and pressure-swirl full-cone nozzles designed for the purpose; the third configuration utilizes a pump to boost the oil pressure. The laser imagining technique shows that the nozzles generate sprays that break-up within a short distance into spherical droplets, ligaments, ramifications and undefined structures. Tests on the packaged compressors reveal that the advanced configurations provide almost the same air flow rate while utilizing half of the oil because the sprays generate a good sealing. Moreover, the sprayed oil is acting as a thermal ballast because the electrical input is reduced by 3.5% and 3.0%, respectively, if the pump is present or not , while the specific energy requirement, accounting for the slightly reduced air flow, by 2.4% and 2.9%, respectively.

  1. The Analysis for the Effect of Mixing Vane Shape on TDC

    International Nuclear Information System (INIS)

    Moon, Kang Hoon; Park, Ho Young; Kim, Kang Hoon; Park, Eung Jun; Suh, Jung Min

    2011-01-01

    The Thermal Diffusion Coefficient (TDC) is an input parameter to subchannel code, and it is required to predict local flow conditions in a PWR fuel bundle. TDC influences on the prediction of thermal interchange or mixing of thermal energy between the hot subchannel and interconnected adjacent subchannels. The thermal mixing term in the energy equation is generally represented in terms of a non-dimensional inverse Peclet number or TDC. The parameters associated with thermal mixing can be defined as Eq.(1): TDC =Pe x De/a (1) where: Pe : Inverse Peclet Number (dimensionless) = ε/ Va De : Equivalent hydraulic diameter, in. a : Lateral flow area between channels per unit length, in 2 /in ε : Mixing coefficient, in 2 /sec V : Velocity, in/sec TDC is an important factor to evaluate thermal performance. So, flow temperature maps were obtained from the 5x5 rod bundle test section to assess the thermal performance of corresponding fuels. The flow temperatures were measured by thermocouple at the end of heated length and the centroid of subchannel. There are two typical methods to arrange the hot and cold fuel rods as shown in Fig. 1. Configuration Fig. 1(b) is adopted in this work. This paper presents how to determine the TDC and verifies whether all TDC with the effect of mixing vane shape is valid with respect to current design value

  2. Transition Process from Diffuser Stall to Stage Stall in a Centrifugal Compressor with a Vaned Diffuser

    Directory of Open Access Journals (Sweden)

    Nobumichi Fujisawa

    2017-01-01

    Full Text Available The transition process from a diffuser rotating stall to a stage stall in a centrifugal compressor with a vaned diffuser was investigated by experimental and numerical analyses. From the velocity measurements, it was found that the rotating stall existed on the shroud side of the diffuser passage in the off-design flow condition. The numerical results revealed the typical vortical structure of the diffuser stall. The diffuser stall cell was caused by the systematic vortical structure which consisted of the tornado-type vortex, the longitudinal vortex at the shroud/suction surface corner (i.e., leading edge vortex (LEV, and the vortex in the throat area of the diffuser passages. Furthermore, the stage stall, which rotated within both the impeller and diffuser passages, occurred instead of the diffuser stall as the mass flow rate was decreased. According to the velocity measurements at the diffuser inlet, the diffuser stall which rotated on the shroud side was shifted to the hub side. Then, the diffuser stall moved into the impeller passages and formed the stage stall. Therefore, the stage stall was caused by the development of the diffuser stall, which transferred from the shroud side to the hub side in the vaneless space and expanded to the impeller passages.

  3. Effects of Radial Gap Ratio between Impeller and Vaned Diffuser on Performance of Centrifugal Compressors

    Directory of Open Access Journals (Sweden)

    Mohammadjavad Hosseini

    2017-07-01

    Full Text Available A high-performance centrifugal compressor is needed for numerous industry applications nowadays. The radial gap ratio between the impeller and the diffuser vanes plays an important role in the improvement of the compressor performance. In this paper, the effects of the radial gap ratio on a high-pressure ratio centrifugal compressor are investigated using numerical simulations. The performance and the flow field are compared for six different radial gap ratios and five rotational speeds. The minimal radial gap ratio was 1.04 and the maximal was 1.14. Results showed that reducing the radial gap ratio decreases the choke mass flow rate. For the tip-speed Mach number (impeller inlet with Mu < 1, the pressure recovery and the loss coefficients are not sensitive to the radial gap ratio. However, for Mu ≥ 1, the best radial gap ratio is 1.08 for the pressure recovery and the loss coefficients. Furthermore, the impeller pressure ratio and efficiency are reduced by increasing the radial gap ratio. Finally, the compressor efficiency was compared for different radial gap ratios. For Mu < 1, the radial gap ratio does not have noticeable effects. In comparison, the radial gap ratio of 1.08 has the best performance for Mu ≥ 1.

  4. A Study of Performance Output of a Multivane Air Engine Applying Optimal Injection and Vane Angles

    Directory of Open Access Journals (Sweden)

    Bharat Raj Singh

    2012-01-01

    Full Text Available This paper presents a new concept of the air engine using compressed air as the potential power source for motorbikes, in place of an internal combustion engine. The motorbike is proposed to be equipped with an air engine, which transforms the energy of the compressed air into mechanical motion energy. A mathematical model is presented here, and performance evaluation is carried out on an air-powered novel air turbine engine. The maximum power output is obtained as 3.977 kW (5.50 HP at the different rotor to casing diameter ratios, optimal injection angle 60°, vane angle 45° for linear expansion (i.e., at minimum air consumption when the casing diameter is kept 100 mm, at injection pressure 6 bar (90 psi and speed of rotation 2500 rpm. A prototype air engine is built and tested in the laboratory. The experimental results are also seen much closer to the analytical values, and the performance efficiencies are recorded around 70% to 95% at the speed of rotation 2500–3000 rpm.

  5. Numerical Study of Compact Plate-Fin Heat Exchanger for Rotary-Vane Gas Refrigeration Machine

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2017-10-01

    Full Text Available Plate-fin heat exchangers are widely used in refrigeration technique. They are popular because of their compactness and excellent heat transfer performance. Here we present a numerical model for the development, research and optimization of a plate-fin heat exchanger for a rotary-vane gas refrigeration machine. The method of analysis by graphic method of plate - fin heat exchanger is proposed. The model describes the effects of secondary parameters such as axial thermal conductivity through a metal matrix of the heat exchanger. The influence of geometric parameters and heat transfer coefficient is studied. Graphs of dependences of length, efficiency of a fin and pressure drop in a heat exchanger on the thickness of the fin and the number of fins per meter are obtained. To analyze the results of numerical simulation, the heat exchanger was designed in the Aspen HYSYS program. The simulation results show that the total deviation from the proposed numerical model is not more than 15%. 

  6. Active unsteady aerodynamic suppression of rotating stall in an incompressible flow centrifugal compressor with vaned diffuser

    Science.gov (United States)

    Lawless, Patrick B.; Fleeter, Sanford

    1991-01-01

    A mathematical model is developed to analyze the suppression of rotating stall in an incompressible flow centrifugal compressor with a vaned diffuser, thereby addressing the important need for centrifugal compressor rotating stall and surge control. In this model, the precursor to to instability is a weak rotating potential velocity perturbation in the inlet flow field that eventually develops into a finite disturbance. To suppress the growth of this potential disturbance, a rotating control vortical velocity disturbance is introduced into the impeller inlet flow. The effectiveness of this control is analyzed by matching the perturbation pressure in the compressor inlet and exit flow fields with a model for the unsteady behavior of the compressor. To demonstrate instability control, this model is then used to predict the control effectiveness for centrifugal compressor geometries based on a low speed research centrifugal compressor. These results indicate that reductions of 10 to 15 percent in the mean inlet flow coefficient at instability are possible with control waveforms of half the magnitude of the total disturbance at the inlet.

  7. Break-In, Performance, and Endurance Tests Results on Fixed Displacement Hydraulic Fluid Power Vane Pumps.

    Science.gov (United States)

    1982-07-15

    most critical . It is best to install it inside the housing to measure the temperature inside the pump. If the outlet temperature probe is installed in...141I1HL PPE’SSUPL IS: :M49.65 PS It THE S5THNDiAPL L’E’,J.’I- OF (1-HE: r’EASUREL’ F LOW’ 1 ’-:-- A-. caPM MEASURED. S.PEED’I 9 i;*-j3%1 P* MEASURED

  8. Neighbourhood fast food outlets and obesity in children and adults: the CLAN Study.

    Science.gov (United States)

    Crawford, David A; Timperio, Anna F; Salmon, Jo A; Baur, Louise; Giles-Corti, Billie; Roberts, Rebecca J; Jackson, Michelle L; Andrianopoulos, Nick; Ball, Kylie

    2008-01-01

    We examined associations between density of and proximity to fast food outlets and body weight in a sample of children (137 aged 8-9 years and 243 aged 13-15 years) and their parents (322 fathers and 362 mothers). Children's measured and parents' self-reported heights and weights were used to calculate body mass index (BMI). Locations of major fast food outlets were geocoded. Bivariate linear regression analyses examined associations between the presence of any fast food outlet within a 2 km buffer around participants' homes, fast food outlet density within the 2 km buffer, and distance to the nearest outlet and BMI. Each independent variable was also entered into separate bivariate logistic regression analyses to predict the odds of being overweight or obese. Among older children, those with at least one outlet within 2 km had lower BMI z-scores. The further that fathers lived from an outlet, the higher their BMI. Among 13-15-year-old girls and their fathers, the likelihood of overweight/obesity was reduced by 80% and 50%, respectively, if they had at least one fast food outlet within 2 km of their home. Among older girls, the likelihood of being overweight/obese was reduced by 14% with each additional outlet within 2 km. Fathers' odds of being overweight/obese increased by 13% for each additional kilometre to the nearest outlet. While consumption of fast food has been shown to be associated with obesity, this study provides little support for the concept that exposure to fast food outlets in the local neighbourhood increases risk of obesity.

  9. Out-of-home food outlets and area deprivation: case study in Glasgow, UK

    Directory of Open Access Journals (Sweden)

    Cummins Steven

    2005-10-01

    Full Text Available Abstract Background There is a popular belief that out-of-home eating outlets, which typically serve energy dense food, may be more commonly found in more deprived areas and that this may contribute to higher rates of obesity and related diseases in such areas. Methods We obtained a list of all 1301 out-of-home eating outlets in Glasgow, UK, in 2003 and mapped these at unit postcode level. We categorised them into quintiles of area deprivation using the 2004 Scottish Index of Multiple Deprivation and computed mean density of types of outlet (restaurants, fast food restaurants, cafes and takeaways, and all types combined, per 1000 population. We also estimated odds ratios for the presence of any outlets in small areas within the quintiles. Results The density of outlets, and the likelihood of having any outlets, was highest in the second most affluent quintile (Q2 and lowest in the second most deprived quintile (Q4. Mean outlets per 1,000 were 4.02 in Q2, 1.20 in Q4 and 2.03 in Q5. With Q2 as the reference, Odds Ratios for having any outlets were 0.52 (CI 0.32–0.84 in Q1, 0.50 (CI 0.31 – 0.80 in Q4 and 0.61 (CI 0.38 – 0.98 in Q5. Outlets were located in the City Centre, West End, and along arterial roads. Conclusion In Glasgow those living in poorer areas are not more likely to be exposed to out-of-home eating outlets in their neighbourhoods. Health improvement policies need to be based on empirical evidence about the location of fast food outlets in specific national and local contexts, rather than on popular 'factoids'.

  10. T2-weighted liver MRI using the multiVane technique at 3T: Comparison with conventional T2-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kyung A [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Kim, Young Kon; Jeong, Woo Kyoung; Choi, Dong Il; Lee, Won Jae [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Eun Ju [Philips Healthcare Korea, Philips, Seoul (Korea, Republic of); Jung, Sin Ho; Baek, Sun Young [Biostatistics and Clinical Epidemiology Center, Samsung Medical Center, Seoul (Korea, Republic of)

    2015-10-15

    To assess the value of applying MultiVane to liver T2-weighted imaging (T2WI) compared with conventional T2WIs with emphasis on detection of focal liver lesions. Seventy-eight patients (43 men and 35 women) with 86 hepatic lesions and 20 pancreatico-biliary diseases underwent MRI including T2WIs acquired using breath-hold (BH), respiratory-triggered (RT), and MultiVane technique at 3T. Two reviewers evaluated each T2WI with respect to artefacts, organ sharpness, and conspicuity of intrahepatic vessels, hilar duct, and main lesion using five-point scales, and made pairwise comparisons between T2WI sequences for these categories. Diagnostic accuracy (Az) and sensitivity for hepatic lesion detection were evaluated using alternative free-response receiver operating characteristic analysis. MultiVane T2WI was significantly better than BH-T2WI or RT-T2WI for organ sharpness and conspicuity of intrahepatic vessels and main lesion in both separate reviews and pairwise comparisons (p < 0.001). With regard to motion artefacts, MultiVane T2WI or BH-T2WI was better than RT-T2WI (p < 0.001). Conspicuity of hilar duct was better with BH-T2WI than with MultiVane T2WI (p = 0.030) or RT-T2WI (p < 0.001). For detection of 86 hepatic lesions, sensitivity (mean, 97.7%) of MultiVane T2WI was significantly higher than that of BH-T2WI (mean, 89.5%) (p = 0.008) or RT-T2WI (mean, 84.9%) (p = 0.001). Applying the MultiVane technique to T2WI of the liver is a promising approach to improving image quality that results in increased detection of focal liver lesions compared with conventional T2WI.

  11. Remaining Life Estimation Of Secondary Superheater Outlet On Industrial Electrical Boiler

    International Nuclear Information System (INIS)

    Soedardjo; Andryansyah; Arhatari, B.D.; Natsir, Muhammad; Triyadi, Ari; Farokhi

    2001-01-01

    Remaining life estimation of secondary superheater header outlet (SSHO) on industrial electrical boiler has been carried out. Estimation conducted by the observation of microstructure cavitation development based on Neubauer and Wedel theory. The result is available for isolated cavitation development present yet. That Secondary Superheater Outlet component is in good condition after 14 years operated and predicted could be operated for 36 years again

  12. Contamination of faecal coliforms in ice cubes sampled from food outlets in Kubang Kerian, Kelantan.

    Science.gov (United States)

    Noor Izani, N J; Zulaikha, A R; Mohamad Noor, M R; Amri, M A; Mahat, N A

    2012-03-01

    The use of ice cubes in beverages is common among patrons of food outlets in Malaysia although its safety for human consumption remains unclear. Hence, this study was designed to determine the presence of faecal coliforms and several useful water physicochemical parameters viz. free residual chlorine concentration, turbidity and pH in ice cubes from 30 randomly selected food outlets in Kubang Kerian, Kelantan. Faecal coliforms were found in ice cubes in 16 (53%) food outlets ranging between 1 CFU/100mL to >50 CFU/ 100mL, while in the remaining 14 (47%) food outlets, in samples of tap water as well as in commercially bottled drinking water, faecal coliforms were not detected. The highest faecal coliform counts of >50 CFU/100mL were observed in 3 (10%) food outlets followed by 11-50 CFU/100mL and 1-10 CFU/100mL in 7 (23%) and 6 (20%) food outlets, respectively. All samples recorded low free residual chlorine concentration (contamination by faecal coliforms was not detected in 47% of the samples, tap water and commercially bottled drinking water, it was concluded that (1) contamination by faecal coliforms may occur due to improper handling of ice cubes at the food outlets or (2) they may not be the water sources used for making ice cubes. Since low free residual chlorine concentrations were observed (food outlets, including that of ice cube is crucial in ensuring better food and water for human consumption.

  13. Alcohol outlet density and alcohol consumption in Los Angeles county and southern Louisiana

    Directory of Open Access Journals (Sweden)

    Matthias Schonlau

    2008-11-01

    Full Text Available The objective of this study was to assess the relationship between alcohol availability, as measured by the density of off-premise alcohol outlets, and alcohol consumption in Los Angeles county and southern Louisiana, USA. Consumption information was collected through a telephone survey of 2,881 households in Los Angeles county and pre-Katrina southern Louisiana, nested within 220 census tracts. Respondents’ addresses were geo-coded and both neighbourhood (census tracts and buffers of varying sizes and individual (network distance to the closest alcohol outlet estimates of off-sale alcohol outlet density were computed. Alcohol outlet density was not associated with the percentage of people who were drinkers in either site. Alcohol outlet density was associated with the quantity of consumption among drinkers in Louisiana but not in Los Angeles. Outlet density within a one-mile buffer of the respondent’s home was more strongly associated with alcohol consumption than outlet density in the respondent’s census tract. The conclusion is that the relationship between neighbourhood alcohol outlet density and alcohol consumption is complex and may vary due to differences in neighbourhood design and travel patterns.

  14. Survey of Publication Outlets in Early Childhood Education: Descriptive Data, Review Processes, and Advice to Authors

    Science.gov (United States)

    Amodei, Michelle L.; Jalongo, Mary Renck; Myers, Jacqueline; Onchwari, Jacqueline; Gargiulo, Richard M.

    2013-01-01

    Publishing outlets in the field of early childhood vary widely in terms of emphasis on theory, practice, and research as they relate to the care and education of the very young; these outlets also have different readerships (i.e., primarily for teachers, the teachers of their teachers, or the fellow scholars/researchers). Included in the mixture…

  15. Validation of presence of supermarkets and fast-food outlets in Copenhagen

    DEFF Research Database (Denmark)

    Svastisalee, Chalida M; Holstein, Bjørn E; Due, Pernille

    2012-01-01

    We examined the quality of food outlet addresses provided by secondary sources and determined whether they could be physically located in the field.......We examined the quality of food outlet addresses provided by secondary sources and determined whether they could be physically located in the field....

  16. The association between the geography of fast food outlets and childhood obesity rates in Leeds, UK.

    Science.gov (United States)

    Fraser, Lorna K; Edwards, Kimberley L

    2010-11-01

    To analyse the association between childhood overweight and obesity and the density and proximity of fast food outlets in relation to the child's residential postcode. This was an observational study using individual level height/weight data and geographic information systems methodology. Leeds in West Yorkshire, UK. This area consists of 476 lower super-output areas. Children aged 3-14 years who lived within the Leeds metropolitan boundaries (n=33,594). The number of fast food outlets per area and the distance to the nearest fast food outlet from the child's home address. The weight status of the child: overweight, obese or neither. 27.1% of the children were overweight or obese with 12.6% classified as obese. There is a significant positive correlation (pfood outlets and higher deprivation. A higher density of fast food outlets was significantly associated (p=0.02) with the child being obese (or overweight/obese) in the generalised estimating equation model which also included sex, age and deprivation. No significant association between distance to the nearest fast food outlet and overweight or obese status was found. There is a positive relationship between the density of fast food outlets per area and the obesity status of children in Leeds. There is also a significant association between fast food outlet density and areas of higher deprivation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  17. Study on partial overheat of the isolated phase busbar outlet box in Qinshan NPP phase Ⅱ

    International Nuclear Information System (INIS)

    Tang Fangxuan; Zhang Jian; Zeng Limin; Bao Yanxing; Zhang Lie; Yang Yuemin

    2013-01-01

    This paper recommended the structure of the isolated phase busbar outlet box installed in Qinshan II. The study on partial overheat of the outlet box shows that the ultimate causes are the loss of concentrated eddy current and short of cooling. So the improvement principles of 'distributing eddy current, cutting off inductive circle current and strengthening of ventilation' were determined. A new structure test outlet box was designed and manufactured, and the temperature rising experiment was carried out. Some alterations were made in the new structure outlet box, e.g. isolating materials were added between side plates of the upper outlet box, and also between the upper and lower outlet box. Two cooling blowers were added to the upper outlet box. After putting into operation, the hot-spot temperature of the new outlet box was greatly lowered down. Thus the operation environment was improved, and the operation safety ensured. It can be useful references for analyzing and dealing with similar problems. (authors)

  18. Shopper Loyalty to Whom? Chain Versus Outlet Loyalty in the Context of Store Acquisitions

    NARCIS (Netherlands)

    van Lin, Arjen; Gijsbrechts, E.

    2014-01-01

    When patronizing stores, consumers may exhibit loyalty not only to a retail chain but also to a specific outlet. This distinction is important in a dynamic retail environment: if a store changes ownership, chain loyalty makes customers inclined to seek out another outlet of the former chain, whereas

  19. Shopper loyalty to whom? Chain versus outlet loyalty in the context of store acquisitions

    NARCIS (Netherlands)

    van Lin, A.I.J.G.; Gijsbrechts, E.

    When patronizing stores, consumers may exhibit loyalty not only to a retail chain but also to a specific outlet. This distinction is important in a dynamic retail environment: if a store changes ownership, chain loyalty makes customers inclined to seek out another outlet of the former chain, whereas

  20. Salt Marshes as Monitors of Late Holocene Outlet Glacier Retreat

    Science.gov (United States)

    Wake, L. M.; Woodroffe, S.; Long, A. J.; Milne, G. A.

    2014-12-01

    New proxy sea-level records extracted from salt marshes in the vicinity of Jakobshavn Isbrae (Pakitsoq; 69.51°N, 50.74°W) and at previous sites in central western Greenland (Sisimiut; 66.47°N, 53.61°W and Aasiaat; 68.69°N, 52.88°W) are analyzed with respect to their ability to act as proximal tide gauges detecting mass balance changes in nearby outlet glaciers associated with the transition from the Little Ice Age ("LIA", 1400-1850AD) to the Industrial Period (>1850AD). Data at Pakitsoq demonstrate that sea-level rose at a rate of 3.5 ±1.7 mm/yr prior to 1850AD and slowed to 0.3 ±0.6mm/yr thereafter, producing a slowdown in sea level of 3.2 ± 1.8 mm/yr. A similar slowdown, occurring at 1600AD, is observed at Aasiaat and Sisimiut. We interpret these observed changes using a glacial isostatic adjustment model of sea-level change truncated at degree and order 4096, with an aim to determine if the sea-level data can be used to place constraints on changes in Jakobshavn Isbrae and/or Kangiata Nunaata Sermia (Nuuk fjord) during this period. Modelled sea level at Pakitsoq is insensitive to the location of thickening (thinning) associated with grounding line advance (retreat) and the rate of advance and retreat but is sensitive to the change point in time between periods of growth associated with LIA expansion (sea level rise) and the onset of 19th century recession (sea level fall) of Jakobshavn Isbrae. We conclude that the change in sea-level rate observed at Pakitsoq circa 1850AD marks the onset of post LIA retreat of this outlet glacier. Conversely, the modelled sea-level response to the retreat of Kangiata Nunaata Sermia from its LIA maximum at ca. 1761AD is below the detection threshold of the salt marsh record at Sisimiut.

  1. Pathways of warm water to the Northeast Greenland outlet glaciers

    Science.gov (United States)

    Schaffer, Janin; Timmermann, Ralph; Kanzow, Torsten; Arndt, Jan Erik; Mayer, Christoph; Schauer, Ursula

    2015-04-01

    The ocean plays an important role in modulating the mass balance of the Greenland Ice Sheet by delivering heat to the marine-terminating outlet glaciers surrounding the Greenland coast. The warming and accumulation of Atlantic Water in the subpolar North Atlantic has been suggested to be a potential driver of the glaciers' retreat over the last decades. The shelf regions thus play a critical role for the transport of Atlantic Water towards the glaciers, but also for the transfer of freshwater towards the deep ocean. A key region for the mass balance of the Greenland Ice Sheet is the Northeast Greenland Ice Stream. This large ice stream drains the second-largest basin of the Greenland Ice Sheet and feeds three outlet glaciers. The largest one is Nioghalvfjerdsfjorden (79°N-Glacier) featuring an 80 km long floating ice tongue. Both the ocean circulation on the continental shelf off Northeast Greenland and the circulation in the cavity below the ice tongue are weakly constrained so far. In order to study the relevant processes of glacier-ocean interaction we combine observations and model work. Here we focus on historic and recent hydrographic observations and on the complex bathymetry in the Northeast Greenland shelf region, which is thought to steer the flux of warm Atlantic water onto the continental shelf and into the sub-ice cavity beneath the 79°N-Glacier. We present a new global topography data set, RTopo-2, which includes the most recent surveys on the Northeast Greenland continental shelf and provides a detailed bathymetry for all around Greenland. In addition, RTopo-2 contains ice and bedrock surface topographies for Greenland and Antarctica. Based on the updated ocean bathymetry and a variety of hydrographic observations we show the water mass distribution on the continental shelf off Northeast Greenland. These maps enable us to discuss possible supply pathways of warm modified Atlantic waters on the continental shelf and thus potential ways of heat

  2. Alcohol beverage control, privatization and the geographic distribution of alcohol outlets

    Directory of Open Access Journals (Sweden)

    Grubesic Tony H

    2012-11-01

    Full Text Available Abstract Background With Pennsylvania currently considering a move away from an Alcohol Beverage Control state to a privatized alcohol distribution system, this study uses a spatial analytical approach to examine potential impacts of privatization on the number and spatial distribution of alcohol outlets in the city of Philadelphia over a long time horizon. Methods A suite of geospatial data were acquired for Philadelphia, including 1,964 alcohol outlet locations, 569,928 land parcels, and school, church, hospital, park and playground locations. These data were used as inputs for exploratory spatial analysis to estimate the expected number of outlets that would eventually operate in Philadelphia. Constraints included proximity restrictions (based on current ordinances regulating outlet distribution of at least 200 feet between alcohol outlets and at least 300 feet between outlets and schools, churches, hospitals, parks and playgrounds. Results Findings suggest that current state policies on alcohol outlet distributions in Philadelphia are loosely enforced, with many areas exhibiting extremely high spatial densities of outlets that violate existing proximity restrictions. The spatial model indicates that an additional 1,115 outlets could open in Philadelphia if privatization was to occur and current proximity ordinances were maintained. Conclusions The study reveals that spatial analytical approaches can function as an excellent tool for contingency-based “what-if” analysis, providing an objective snapshot of potential policy outcomes prior to implementation. In this case, the likely outcome is a tremendous increase in alcohol outlets in Philadelphia, with concomitant negative health, crime and quality of life outcomes that accompany such an increase.

  3. Laboratory determination of normal operating flow rates with enlarged outlet fittings -- BDF reactors

    Energy Technology Data Exchange (ETDEWEB)

    Waters, E.D.

    1960-02-02

    Experiments have been conducted in the Hydraulics Laboratory, at the request of IPD`s Mechanical Development-A Operation, to determine the energy losses of various enlarged outlet fitting combinations. These experiments were conducted an steady state runs and allow the determination of the normal operating point (flow rate) of a reactor process channel under selected conditions of front header pressure and fuel charge. No attempt is made to make a mechanical or economic evaluation of the particular fitting combinations, although observations were noted which might bear on this evaluation. It is very important for the reader to bear in mind that changing outlet fittings will definitely affect the reactor tube power limits and outlet vater temperature limits. The size of the outlet fittings largely determines the present outlet temperature limits of the old reactors. The flow characteristics of these present fittings cause some degree of pressurization to suppress boiling on the fuel charge and also cause dual Panellit trip protection for certain flow changes and for power surges. Enlargement of the outlet fittings may actually reduce the allowable outlet coolant temperature limits. Since these effects cannot be determined on the apparatus used in these experiments, a complete discussion of this point is not included in this report. However, the seriousness of these effects should be known and carefully analyzed before a final selection of enlarged outlet fittings in made. This report will be one of a series. New reports in the series will be issued as data are obtained for other such outlet fitting combinations or for new concepts of outlet fitting assemblies such as the new nozzle being developed by C. E. Trantz for use on F-reactor stuck gunbarrel tubes.

  4. Tobacco outlet density and tobacco knowledge, beliefs, purchasing behaviours and price among adolescents in Scotland.

    Science.gov (United States)

    Tunstall, Helena; Shortt, Niamh K; Niedzwiedz, Claire L; Richardson, Elizabeth A; Mitchell, Richard J; Pearce, Jamie R

    2018-06-01

    Despite long-term falls in global adult smoking prevalence and over 50 years of tobacco control policies, adolescent smoking persists. Research suggests greater densities of tobacco retail outlets in residential neighbourhoods are associated with higher adolescent smoking rates. Policies to reduce retail outlets have therefore been identified by public health researchers as a potential 'new frontier' in tobacco control. Better understanding of the pathways linking density of tobacco retailers and smoking behaviour could support these policies. In this study we use path analysis to assess how outlet density in the home environment is related to adolescent tobacco knowledge, beliefs, retail purchases and price in Scotland. We assessed 22,049 13 and 15 year old respondents to the nationally representative cross-sectional 2010 Scottish School Adolescent Lifestyle and Substance Use Survey. Outlet density was based on Scottish Tobacco Retailers Register, 2012, data. A spatially-weighted Kernel Density Estimation measure of outlet density within 400 m of respondents' home postcode was grouped into tertiles. The analysis considered whether outlet density was associated with the number of cigarette brands adolescents could name, positive beliefs about smoking, whether smokers purchased cigarettes from shops themselves or through adult proxies and perceived cost of cigarettes. Models were stratified by adolescent smoking status. The path analyses indicated that outlet density was not associated with most outcomes, but small, significant direct effects on knowledge of cigarette brands among those who had never smoked were observed. With each increase in outlet density tertile the mean number of brands adolescents could name rose by 0.07 (mean = 1.60; SD = 1.18; range = 4). This suggests greater outlet densities may have affected adolescents' knowledge of cigarette brands but did not encourage positive attitudes to smoking, purchases from shops or lower cigarette

  5. Electronic Cigarette Retail Outlets and Proximity to Schools.

    Science.gov (United States)

    Hahn, Ellen J; Begley, Kathy; Gokun, Yevgeniya; Johnson, Andrew O; Mundy, Monica E; Rayens, Mary Kay

    2015-01-01

    To compare the retail distribution and density per population of electronic and conventional cigarettes in smoke-free communities with and without e-cigarette restrictions. A cross-sectional study with field observations of retail tobacco stores. Two Central Kentucky counties with 100% smoke-free workplace regulations; counties selected on the basis of whether e-cigarette use was restricted. Fifty-seven tobacco retailers in two counties, including conventional retailers and stand-alone e-cigarette stores. Type and location of store and products sold; addresses of stores and schools geocoded with ArcGIS. Bivariate comparisons between counties, rates and confidence intervals for frequency of tobacco retailers and e-cigarette stores per population. Fifty-three percent of tobacco retailers sold e-cigarettes. E-cigarette availability did not differ by whether smoke-free regulation covered e-cigarettes. Rates of tobacco retailers and e-cigarette distributors per 10,000 were 8.29 and 4.40, respectively, in the two-county area. Of the 40 schools, 88% had a tobacco retailer and 68% had an e-cigarette distributor within 1 mile. In this exploratory study, e-cigarette use restriction was not related to store availability. For a relatively new product, e-cigarettes were readily available in retail outlets and close to schools.

  6. Bladder outlet obstruction (BOO) in female: etiology and management

    International Nuclear Information System (INIS)

    Shaikh, N.A.; Ahuja, K.; Shaikh, G.S.; Soomro, A.K.

    2015-01-01

    To determine the etiology and management outcome of bladder outlet obstruction (BOO) in female. Methodology: From 2009 to 2012, 37 females with a mean age of 40 (range 20-65) were investigated for etiology and management outcome of BOO. Typical complaints were slow urinary flow, difficulty in emptying bladder, frequency of micturition and urgency. Mean duration of symptoms was 6 month. Results: 15 women were confirmed as atrophic urethritis, 5 had functional bladder, 3 had urethral caruncle, 5 had cystocele, 7 had complete procedentia of uterus, and 2 had impacted urethral stone. Cystoscopy was performed in all patients to exclude other pathology like vesical stone and bladder growth. 12 patients were referred to Gynecology due to complete procedentia of uterus and cystocele. Three cases of urethral caruncle were treated by excision and biopsy, 2 patients with urethral stone were treated by endoscopic push back and litholapaxy while 5 required conservative treatment and 15 cases of atrophic urethritis were kept on Hormone Replacement Therapy (HRT). Conclusion: BOO is uncommon in female and management depends upon the etiology. (author)

  7. Detention Outlet Retrofit Improves the Functionality of Existing ...

    Science.gov (United States)

    Journal Article Provide a stormwater management device for States and watershed management organizations. By discharging excess stormwater runoff at rates that more frequently exceed the critical flow for stream channel erosion, conventional detention basins often contribute to the escalated levels of instability that are common in urban and suburban streams and can be detrimental to aquatic habitat and water quality, as well as adjacent property and infrastructure. However, these ubiquitous assets, valued at ca. $600,000/km2 in a representative suburban watershed in Northern Kentucky, are ideal candidates to aid in reversing such cycles of channel degradation because improving their functionality would not necessarily require property acquisition or heavy construction. The objective of this research was to develop a simple, cost-effective device that could be installed in detention basin outlets to reduce the erosive power of the relatively frequent, but otherwise erosive, storm events (e.g. ~ ≤ 2-yr recurrence) and provide a passive bypass to maintain flood control performance during infrequent storms (e.g. 100-yr recurrence). Results from a pilot installation show that the Detain H2O device can not only meet these goals, but can also contribute to reduced flashiness and prolonged baseflows in receiving streams. When scaling the strategy across a watershed, these results suggest that substantial gains in water quality and stream channel stability could b

  8. The VanE operon in Enterococcus faecalis N00-410 is found on a putative integrative and conjugative element, Tn6202.

    Science.gov (United States)

    Boyd, D A; Mulvey, M R

    2013-02-01

    To date no complete genetic structure of acquired DNA harbouring a d-Ala-d-Ser operon in an Enterococcus is known. We wished to characterize the acquired DNA harbouring the vanE operon located in the Enterococcus faecalis N00-410 chromosome. Whole genome sequencing of E. faecalis N00-410 was conducted by massively parallel sequencing. Two sequence contigs harbouring the vanE region were linked by PCR and the acquired DNA harbouring the vanE operon was completely characterized. Excision/integration of the region was determined by PCR and transfer attempted by conjugation. The regions flanking the vanE operon were analysed and a total of 42 open reading frames were identified in a region flanked by inverted terminal and direct repeats (Tn6202). Tn6202 could be excised from the chromosome, circularized and the target site rejoined, but transfer could not be demonstrated. The vanE operon was found on the putative integrative and conjugative element Tn6202 in the E. faecalis N00-410 chromosome. This represents the first characterization of acquired DNA harbouring a D-Ala-D-Ser operon.

  9. Numerical research on the effects of impeller pump-out vanes on axial force in a solid-liquid screw centrifugal pump

    International Nuclear Information System (INIS)

    Cheng, X R; Li, R N; Gao, Y; Guo, W L

    2013-01-01

    A commercial CFD code has been used to predict the performance of a screw centrifugal pump with pump-out vanes, especially when changing regularity of impeller axial force based on the solid-liquid two-phase flow. The Unsteady Reynolds Averaged Navier-Stokes (URANS) approach has been applied to solve the unsteady, incompressible, three-dimensional turbulent. The SIMPLEC algorithm, standard wall functions and mix two-phase flow model were applied. The RNG k ε-model was used to account the turbulence effects. By changing the number of impeller pump-out vanes and width, six different screw centrifugal pump numerical simulation projects were given, and each scheme in the different solid volume fraction were calculated respectively. The change rules of axial force, velocity and pressure distribution of flow field were obtained on the different condition and different volume fraction. The results showed that the axial forces values based solid-fluid two-phase greater than based single-phase clear water, but both changing regularity of the axial force were consistent; as same condition, the same solid-phase volume concentration, with the increase of pump-out vanes number or width, the impeller axial force increased as well. Meanwhile the number of the pump-out vanes and the width of pump-out vanes in balancing the impeller axial force, there are the most optimal value

  10. Change of performance of a horizontal wind turbine with V type tip vane%风力机加V型小翼后的性能变化

    Institute of Scientific and Technical Information of China (English)

    贾瑞博; 汪建文

    2011-01-01

    试验和数值模拟证明,在风力机叶片的叶尖添加小翼,可以提高风能转化效率.为了清楚地了解小翼对风力机动力放大的影响,文章基于叶轮周围流场的数值模拟结果,分析了加V型小翼和不加小翼的风力机流场-速度场和压力场特性.可以看出,小翼对风力机叶片叶端的影响较大,风力机叶尖的漩涡强度降低,能量转换效率提高.%It was proved that a tip vane could improve thewind turbine's efficiency by the test and the numerical simulation. In order to distinctly understand the power augmentation effect of the wind turbine by the tip vane, this paper analyzed the flow field of the wind turbine with the V type tip vane and without a tip vane, as well as the characteristics of the velocity field and the pressure field, which based on the numerical simulation result of the flow field of the wind turbine. The tip vane has more influence to the blade tip of the wind turbine. The vortex intensity around the blade tip was reduced and the energy transformation efficiency was improved.

  11. The impact of interventions to promote healthier ready-to-eat meals (to eat in, to take away or to be delivered) sold by specific food outlets open to the general public: a systematic review.

    Science.gov (United States)

    Hillier-Brown, F C; Summerbell, C D; Moore, H J; Routen, A; Lake, A A; Adams, J; White, M; Araujo-Soares, V; Abraham, C; Adamson, A J; Brown, T J

    2017-02-01

    Ready-to-eat meals sold by food outlets that are accessible to the general public are an important target for public health intervention. We conducted a systematic review to assess the impact of such interventions. Studies of any design and duration that included any consumer-level or food-outlet-level before-and-after data were included. Thirty studies describing 34 interventions were categorized by type and coded against the Nuffield intervention ladder: restrict choice = trans fat law (n = 1), changing pre-packed children's meal content (n = 1) and food outlet award schemes (n = 2); guide choice = price increases for unhealthier choices (n = 1), incentive (contingent reward) (n = 1) and price decreases for healthier choices (n = 2); enable choice = signposting (highlighting healthier/unhealthier options) (n = 10) and telemarketing (offering support for the provision of healthier options to businesses via telephone) (n = 2); and provide information = calorie labelling law (n = 12), voluntary nutrient labelling (n = 1) and personalized receipts (n = 1). Most interventions were aimed at adults in US fast food chains and assessed customer-level outcomes. More 'intrusive' interventions that restricted or guided choice generally showed a positive impact on food-outlet-level and customer-level outcomes. However, interventions that simply provided information or enabled choice had a negligible impact. Interventions to promote healthier ready-to-eat meals sold by food outlets should restrict choice or guide choice through incentives/disincentives. Public health policies and practice that simply involve providing information are unlikely to be effective. © 2016 The Authors. Obesity Reviews published by John Wiley & Sons Ltd on behalf of World Obesity Federation.

  12. Prospects for the domestic production of large-sized cast blades and vanes for industrial gas turbines

    Science.gov (United States)

    Kazanskiy, D. A.; Grin, E. A.; Klimov, A. N.; Berestevich, A. I.

    2017-10-01

    Russian experience in the production of large-sized cast blades and vanes for industrial gas turbines is analyzed for the past decades. It is noted that the production of small- and medium-sized blades and vanes made of Russian alloys using technologies for aviation, marine, and gas-pumping turbines cannot be scaled for industrial gas turbines. It is shown that, in order to provide manufacturability under large-scale casting from domestic nickel alloys, it is necessary to solve complex problems in changing their chemical composition, to develop new casting technologies and to optimize the heat treatment modes. An experience of PAO NPO Saturn in manufacturing the blades and vanes made of ChS88U-VI and IN738-LC foundry nickel alloys for the turbines of the GTE-110 gas turbine unit is considered in detail. Potentialities for achieving adopted target parameters for the mechanical properties of working blades cast from ChS88UM-VI modified alloy are established. For the blades made of IN738-LC alloy manufactured using the existing foundry technology, a complete compliance with the requirements of normative and technical documentation has been established. Currently, in Russia, the basis of the fleet of gas turbine plants is composed by foreign turbines, and, for the implementation of the import substitution program, one can use the positive experience of PAO NPO Saturn in casting blades from IN738-LC alloy based on a reverse engineering technique. A preliminary complex of studies of the original manufacturer's blades should be carried out, involving, first of all, the determination of geometric size using modern measurement methods as well as the studies on the chemical compositions of the used materials (base metal and protective coatings). Further, verifying the constructed calculation models based on the obtained data, one could choose available domestic materials that would meet the operating conditions of the blades according to their heat resistance and corrosion

  13. Extended residence time centrifugal contactor design modification and centrifugal contactor vane plate valving apparatus for extending mixing zone residence time

    Science.gov (United States)

    Wardle, Kent E.

    2017-06-06

    The present invention provides an annular centrifugal contactor, having a housing adapted to receive a plurality of flowing liquids; a rotor on the interior of the housing; an annular mixing zone, wherein the annular mixing zone has a plurality of fluid retention reservoirs with ingress apertures near the bottom of the annular mixing zone and egress apertures located above the ingress apertures of the annular mixing zone; and an adjustable vane plate stem, wherein the stem can be raised to restrict the flow of a liquid into the rotor or lowered to increase the flow of the liquid into the rotor.

  14. Boundary layer models for calving marine outlet glaciers

    Directory of Open Access Journals (Sweden)

    C. Schoof

    2017-10-01

    Full Text Available We consider the flow of marine-terminating outlet glaciers that are laterally confined in a channel of prescribed width. In that case, the drag exerted by the channel side walls on a floating ice shelf can reduce extensional stress at the grounding line. If ice flux through the grounding line increases with both ice thickness and extensional stress, then a longer shelf can reduce ice flux by decreasing extensional stress. Consequently, calving has an effect on flux through the grounding line by regulating the length of the shelf. In the absence of a shelf, it plays a similar role by controlling the above-flotation height of the calving cliff. Using two calving laws, one due to Nick et al. (2010 based on a model for crevasse propagation due to hydrofracture and the other simply asserting that calving occurs where the glacier ice becomes afloat, we pose and analyse a flowline model for a marine-terminating glacier by two methods: direct numerical solution and matched asymptotic expansions. The latter leads to a boundary layer formulation that predicts flux through the grounding line as a function of depth to bedrock, channel width, basal drag coefficient, and a calving parameter. By contrast with unbuttressed marine ice sheets, we find that flux can decrease with increasing depth to bedrock at the grounding line, reversing the usual stability criterion for steady grounding line location. Stable steady states can then have grounding lines located on retrograde slopes. We show how this anomalous behaviour relates to the strength of lateral versus basal drag on the grounded portion of the glacier and to the specifics of the calving law used.

  15. Gastric Outlet Obstruction Palliation: A Novel Stent-Based Solution

    Directory of Open Access Journals (Sweden)

    Natasha M. Rueth

    2010-06-01

    Full Text Available Gastric outlet obstruction (GOO after esophagectomy is a morbid outcome and significantly hinders quality of life for end-stage esophageal cancer patients. In the pre-stent era, palliation consisted of chemotherapy, radiation, tumor ablation, or stricture dilation. In the current era, palliative stenting has emerged as an additional tool; however, migration and tumor ingrowth are ongoing challenges. To mitigate these challenges, we developed a novel, hybrid, stent-based approach for the palliative management of GOO. We present a patient with esophageal cancer diagnosed with recurrent, metastatic disease 1 year after esophagectomy. She developed dehydration and intractable emesis, which significantly interfered with her quality of life. For palliation, we dilated the stenosis and proceeded with our stent-based solution. Using a combined endoscopic and fluoroscopic approach, we placed a 12-mm silicone salivary bypass tube across the pylorus, where it kinked slightly because of local tumor biology. To bridge this defect and ensure luminal patency, we placed a nitinol tracheobronchial stent through the silicone stent. Clinically, the patient had immediate relief from her pre-operative symptoms and was discharged home on a liquid diet. In conclusion, GOO and malignant dysphagia after esophagectomy are significant challenges for patients with end-stage disease. Palliative stenting is a viable option, but migration and tumor ingrowth are common complications. The hybrid approach presented here provides a unique solution to these potential pitfalls. The flared silicone tube minimized the chance of migration and impaired tumor ingrowth. The nitinol stent aided with patency and overcame the challenges of the soft tube. This novel strategy achieved palliation, describing another endoscopic option in the treatment of malignant GOO.

  16. Availability of healthier options in traditional and nontraditional rural fast-food outlets

    Directory of Open Access Journals (Sweden)

    McIntosh Alex

    2008-11-01

    Full Text Available Abstract Background Food prepared away from home has become increasingly popular to U.S. families, and may contribute to obesity. Sales have been dominated by fast food outlets, where meals are purchased for dining away from home or in the home. Although national chain affiliated fast-food outlets are considered the main source for fast food, fast foods are increasingly available in convenience stores and supermarkets/grocery stores. In rural areas, these nontraditional fast-food outlets may provide most of the opportunities for procurement of fast foods. Methods Using all traditional and nontraditio nal fast-food outlets identified in six counties in rural Texas, the type and number of regular and healthiermenu options were surveyed using on-site observation in all food venues that were primarily fast food, supermarket/grocery store, and convenience store and compared with 2005 Dietary Guidelines. Results Traditional fast-food outlets represented 84 (41% of the 205 opportunities for procurement of fast food; 109 (53.2% were convenience stores and 12 (5.8% supermarkets/grocery stores. Although a s imilar variety of regular breakfast and lunch/dinner entrées were available in traditional fast-food outlets and convenience stores, the variety of healthier breakfast and lunch/dinner entrées was significantly greater in fast food outlets. Compared with convenience stores, supermarkets/grocery stores provided a greater variety of regular and healthier entrées and lunch/dinner side dishes. Conclusion Convenience stores and supermarkets/grocery stores more than double the potential access to fast foods in this rural area than traditional fast-food outlets alone; however, traditional fast food outlets offer greater opportunity for healthier fast food options than convenience stores. A complete picture of fast food environment and the availability of healthier fast food options are essential to understand environmental influences on diet and health

  17. The “School Foodshed”: schools and fast-food outlets in a London borough

    OpenAIRE

    Caraher, M.; Lloyd, S.; Madelin, T.

    2014-01-01

    Purpose – The purpose of this paper is to explore the location of fast-food outlets around secondary schools and the influence of fast-food availability on the food choices of school children in an inner-London borough. \\ud \\ud Design/methodology/approach – A number of methods including: mapping of outlets relative to schools; sampling food; gathering data on secondary school food policies; observing food behaviour in fast food outlets and focus groups with young people. Findings were fed bac...

  18. Impact of remodeling and rehabilitation of irrigation outlets on water distribution of a canal in Punjab, Pakistan

    International Nuclear Information System (INIS)

    Bodla, H.; Latif, M.

    2009-01-01

    The study was undertaken to investigate water distribution along a distributary canal located in the southern part of the Punjab Province. It is a large size distributary having 353 cusecs of authorized discharge. This distributary was subjected to a series of problems including but not limited to (i) withdrawal of water by illegal means, (ii) design and construction flaws in the outlets, (iii) improper selection of the type of outlets and many others. The outlets were intentionally designed wrongly by using fictitious hydraulics data to provide undue benefits to the irrigators. During construction, setting of the outlets was also intentionally fixed at lower level than the designed. Investigations were carried out to evaluate hydraulic performance of all the outlets of the channel. Based on the observed data capacity statements of all the outlets were revised. The outlets were redesigned on the basis of actual hydraulic data of each outlet. Most of the non-modular outlets (Pipe and Scratchley) were converted to semi-modular outlets (OFRB and APM). With implementation of new and modified design of the outlets at the site, equity of water distribution has been improved. The results revealed that design of the outlets had a significant impact on equitable distribution of water along the distribution. (author)

  19. 16 CFR Appendix B to Part 436 - Sample Item 20(1) Table-Systemwide Outlet Summary

    Science.gov (United States)

    2010-01-01

    ... DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. B Appendix B to Part 436—Sample... 1Outlet Type Column 2Year Column 3Outlets at the Start of the Year Column 4Outlets at the End of the Year...

  20. 16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...

  1. Effects of Mie tip-vane on pressure distribution of rotor blade and power augmentation of horizontal axis wind turbine; Yokutan shoyoku Mie ben ni yoru suiheijiku fusha yokumenjo no atsuryoku bunpu no kaizen to seino kojo tono kankei

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Y.; Maeda, T.; Kamada, Y. [Mie Univ., Mie (Japan); Seto, H. [Mitsubishi Motors Corp., Tokyo (Japan)

    2000-04-01

    By recent developments of exclusive rotor blade, the efficiency of wind turbine is improved substantially. By measuring pressure on rotor blades of horizontal axis wind turbines rotating in wind tunnels, this report clarified relation between improvement of pressure distribution on main rotor blades by Mie vane and upgrade of wind turbine performance. The results under mentioned have been got by measuring pressure distribution on rotor blades, visualization by tuft, and measuring resistance of Mie vane. (1) The difference of pressure between suction surface and pressure surface on the end of rotor blade increase, and output power of wind turbine improves. (2) Vortex of blade end is inhibited by Mie vane. (3) The reason of reduction on wind turbine performance with Mie vane in aria of high rotating speed ratio is the increase of Mie vane flow resistance.(NEDO)

  2. Investigating temporal patterns of a native bee community in a remnant North American bunchgrass prairie using blue vane traps.

    Science.gov (United States)

    Kimoto, Chiho; Debano, Sandra J; Thorp, Robbin W; Rao, Sujaya; Stephen, William P

    2012-01-01

    Native bees are important ecologically and economically because their role as pollinators fulfills a vital ecosystem service. Pollinators are declining due to various factors, including habitat degradation and destruction. Grasslands, an important habitat for native bees, are particularly vulnerable. One highly imperiled and understudied grassland type in the United States is the Pacific Northwest Bunchgrass Prairie. No studies have examined native bee communities in this prairie type. To fill this gap, the bee fauna of the Zumwalt Prairie, a large, relatively intact remnant of the Pacific Northwest Bunchgrass Prairie, was examined. Native bees were sampled during the summers of 2007 and 2008 in sixteen 40-ha study pastures on a plateau in northeastern Oregon, using a sampling method not previously used in grassland studies-blue vane traps. This grassland habitat contained an abundant and diverse community of native bees that experienced marked seasonal and inter-annual variation, which appears to be related to weather and plant phenology. Temporal variability evident over the entire study area was also reflected at the individual trap level, indicating a consistent response across the spatial scale of the study. These results demonstrate that temporal variability in bee communities can have important implications for long-term monitoring protocols. In addition, the blue vane trap method appears to be well-suited for studies of native bees in large expanses of grasslands or other open habitats, and may be a useful tool for monitoring native bee communities in these systems.

  3. Experimental comparison of the optical measurements of a cross-flow in a rod bundle with mixing vanes

    International Nuclear Information System (INIS)

    Chang, Seok Kyu; Choo, Yeon Jun; Kim, Bok Deuk; Song, Chul Hwa

    2008-01-01

    The lateral crossflow on subchannels in a rod bundle array was investigated to understand the flow characteristics related to the mixing vane types on a spacer grid by using the PIV technique. For more measurement resolutions, a 5x5 rod bundle was fabricated a 2.6 times larger than the real rod bundle size in a pressurized water reactor. A rod-embedded optic array was specially designed and used for the illumination of the inner subchannels. The crossflow field in a subchannel was characterized by the type and the arrangement of the mixing vanes. At a near downstream location from the spacer grid (z/D h =1) in the case of the split type, a couple of small vortices were generated diagonally in a subchannel. On the other hand, in the case of the swirl type, there was a large elliptic vortex generated in the center of a subchannel. The measurement results were compared with the experimental results which had been performed with the LDV technique at the same test facility. The magnitudes of the flow velocity and the vorticity in PIV results were less than those in LDV measurement results. It was shown that the instantaneous flow fields in a subchannel frequently have quite different shapes from the averaged one

  4. PIV measurement at the blowdown pipe outlet. [Particle Image Velocimetry

    Energy Technology Data Exchange (ETDEWEB)

    Puustinen, M.; Laine, J.; Raesaenen, A.; Pyy, L.; Telkkae, J. [Lappeenranta Univ. of Technology, Lappeenranta (Finland)

    2013-04-15

    This report summarizes the findings of the PIV measurement tests carried out in January - February 2013 with the scaled down PPOOLEX test facility at LUT. The main objective of the tests was to find out the operational limits of the PIV system regarding suitable test conditions and correct values of different adjustable PIV parameters. An additional objective was to gather CFD grade data for verification/validation of numerical models. Both water and steam injection tests were carried out. PIV measurements with cold water injection succeeded well. Raw images were of high quality, averaging over the whole measurement period could be done and flow fields close to the blowdown pipe outlet could be determined. In the warm water injection cases the obtained averaged velocity field images were harder to interpret, especially if the blowdown pipe was also filled with warm water in the beginning of the measurement period. The absolute values of the velocity vectors seemed to be smaller than in the cold water injection cases. With very small steam flow rates the steam/water interface was inside the blowdown pipe and quite stable in nature. The raw images were of good quality but due to some fluctuation in the velocity field averaging of the velocity images over the whole measured period couldn't be done. Condensation of steam in the vicinity of the pipe exit probably caused these fluctuations. A constant outflow was usually followed by a constant inflow towards the pipe exit. Vector field images corresponding to a certain phase of the test could be extracted and averaged but this would require a very careful analysis so that the images could be correctly categorized. With higher steam flow rates rapid condensation of large steam bubbles created small gas bubbles which were in front of the measurement area of the PIV system. They disturbed the measurements by reflecting laser light like seeding particles and therefore the raw images were of poor quality and they couldn

  5. 5 CFR 591.217 - In which outlets does OPM collect prices?

    Science.gov (United States)

    2010-01-01

    ... data collection areas, accessibility by road, physical size, advertising, and other characteristics that reflect sales volume. To the extent practical, OPM prices like items in the same types of outlets...

  6. Is there an association between home-tobacco outlet proximity and smoking status in Denmark?

    DEFF Research Database (Denmark)

    Berg-Beckhoff, Gabriele; K Seid, Abdu; Stock, Christiane

    2017-01-01

    and/or tobacco outlets on smoking habits for the first time in a population based survey in Denmark. Method: Data came from the 2011 Danish national alcohol and drug survey of the Centre for Alcohol and Drug Research of Aarhus University (response rate 64%) and registries of Statistics Denmark were...... between residing close to a tobacco outlet and the prevalence of current and previous smoking. However, no significant association was found between distance from residence to tobacco outlets and smoking habits. Discussion: The prevalence of current smokers (24%) is in accordance with the 2011 annual......Abstract It is well established that exposure to point-of-sale tobacco promotion or impulse purchases and access to and distance to tobacco outlets are related to youth and adult smoking. The aim of the present study was to examine the association of distance from residence to the nearest alcohol...

  7. Is proximity to alcohol outlets associated with alcohol consumption and alcohol-related harm in Denmark?

    DEFF Research Database (Denmark)

    Kedir, Abdu; Berg-Beckhoff, Gabriele; Stock, Christiane

    2018-01-01

    Background: This study examined the associations between distance from residence to the nearest alcohol outlet with alcohol consumption as well as with alcohol-related harm. Methods: Data on alcohol consumption, alcohol-related harm and sociodemographics were obtained from the 2011 Danish Drug...... and Alcohol Survey (n=5133) with respondents aged 15–79 years. The information on distances from residence to the nearest alcohol outlets was obtained from Statistics Denmark. Multiple logistic and linear regressions were used to examine the association between distances to outlets and alcohol consumption...... whereas alcohol-related harm was analysed using negative binomial regression. Results: Among women it was found that those living closer to alcohol outlets were more likely to report alcohol-related harm (p

  8. Is proximity to alcohol outlets associated with alcohol consumption and alcohol-related harm in Denmark?

    DEFF Research Database (Denmark)

    Seid, Abdu K.; Berg-Beckhoff, Gabriele; Stock, Christiane

    2018-01-01

    Background: This study examined the associations between distance from residence to the nearest alcohol outlet with alcohol consumption as well as with alcohol-related harm. Methods: Data on alcohol consumption, alcohol-related harm and sociodemographics were obtained from the 2011 Danish Drug...... and Alcohol Survey (n = 5133) with respondents aged 15–79 years. The information on distances from residence to the nearest alcohol outlets was obtained from Statistics Denmark. Multiple logistic and linear regressions were used to examine the association between distances to outlets and alcohol consumption...... whereas alcohol-related harm was analysed using negative binomial regression. Results: Among women it was found that those living closer to alcohol outlets were more likely to report alcohol-related harm (p

  9. 46 CFR 111.81-1 - Outlet boxes and junction boxes; general.

    Science.gov (United States)

    2010-10-01

    ... fixture, wiring device, or similar item, including each separately installed connection and junction box... used. (d) As appropriate, each outlet-box or junction-box installation must meet the following...

  10. The ICS-'BPH' Study: uroflowmetry, lower urinary tract symptoms and bladder outlet obstruction

    NARCIS (Netherlands)

    Reynard, J. M.; Yang, Q.; Donovan, J. L.; Peters, T. J.; Schafer, W.; de la Rosette, J. J.; Dabhoiwala, N. F.; Osawa, D.; Lim, A. T.; Abrams, P.

    1998-01-01

    To explore the relationship between uroflow variables and lower urinary tract symptoms (LUTS): to define performance statistics (sensitivity, specificity, positive and negative predictive values) for maximum urinary flow rate (Qmax) with respect to bladder outlet obstruction (BOO) at various

  11. Numerical analysis of temperature fluctuation in core outlet region of China experimental fast reactor

    International Nuclear Information System (INIS)

    Zhu Huanjun; Xu Yijun

    2014-01-01

    The temperature fluctuation in core outlet region of China Experimental Fast Reactor (CEFR) was numerically simulated by the CFD software Star CCM+. With the core outlet temperatures, flows etc. under rated conditions given as boundary conditions, a 1/4 region model of the reactor core outlet region was established and calculated using LES method for this problem. The analysis results show that while CEFR operates under rated conditions, the temperature fluctuation in lower part of core outlet region is mainly concentrated in area over the edge components (steel components, control rod assembly), and one in upper part is remarkable in area above all the components. The largest fluctuation amplitude is 19 K and the remarkable frequency is below 5 Hz, and it belongs to typically low frequency fluctuation. The conclusion is useful for further experimental work. (authors)

  12. Transvaginal Mesh and Transanal Resection to Treat Outlet Obstruction Constipation Caused by Rectocele

    OpenAIRE

    Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei

    2017-01-01

    Background The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. Material/Methods Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate...

  13. Beyond Supermarkets: Food Outlet Location Selection in Four U.S. Cities Over Time.

    Science.gov (United States)

    Rummo, Pasquale E; Guilkey, David K; Ng, Shu Wen; Popkin, Barry M; Evenson, Kelly R; Gordon-Larsen, Penny

    2017-03-01

    Understanding what influences where food outlets locate is important for mitigating disparities in access to healthy food outlets. However, few studies have examined how neighborhood characteristics influence the neighborhood food environment over time, and whether these relationships differ by neighborhood-level income. Neighborhood-level data from four U.S. cities (Birmingham, AL; Chicago, IL; Minneapolis, MN; Oakland, CA) from 1986, 1993, 1996, 2001, 2006, and 2011 were used with two-step econometric models to estimate longitudinal associations between neighborhood-level characteristics (z-scores) and the log-transformed count/km 2 (density) of food outlets within real estate-derived neighborhoods. Associations were examined with lagged neighborhood-level sociodemographics and lagged density of food outlets, with interaction terms for neighborhood-level income. Data were analyzed in 2016. Neighborhood-level income at earlier years was negatively associated with the current density of convenience stores (β= -0.27, 95% CI= -0.16, -0.38, prestaurant density in low-income neighborhoods (10th percentile of income: β= -0.17, 95% CI= -0.34, -0.002, p=0.05), and the density of smaller grocery stores across all income levels (β= -0.27, 95% CI= -0.45, -0.09, p=0.003). There was a lack of policy-relevant associations between the pre-existing food environment and the current density of food outlet types, including supermarkets. Socioeconomically disadvantaged and minority populations may attract "unhealthy" food outlets over time. To support equal access to healthy food outlets, the availability of "less healthy" food outlets types may be relatively more important than the potential lack of supermarkets or full-service restaurants. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  14. Neighborhood alcohol outlet density and genetic influences on alcohol use: evidence for gene-environment interaction.

    Science.gov (United States)

    Slutske, Wendy S; Deutsch, Arielle R; Piasecki, Thomas M

    2018-05-07

    Genetic influences on alcohol involvement are likely to vary as a function of the 'alcohol environment,' given that exposure to alcohol is a necessary precondition for genetic risk to be expressed. However, few gene-environment interaction studies of alcohol involvement have focused on characteristics of the community-level alcohol environment. The goal of this study was to examine whether living in a community with more alcohol outlets would facilitate the expression of the genetic propensity to drink in a genetically-informed national survey of United States young adults. The participants were 2434 18-26-year-old twin, full-, and half-sibling pairs from Wave III of the National Longitudinal Study of Adolescent to Adult Health. Participants completed in-home interviews in which alcohol use was assessed. Alcohol outlet densities were extracted from state-level liquor license databases aggregated at the census tract level to derive the density of outlets. There was evidence that the estimates of genetic and environmental influences on alcohol use varied as a function of the density of alcohol outlets in the community. For example, the heritability of the frequency of alcohol use for those residing in a neighborhood with ten or more outlets was 74% (95% confidence limits = 55-94%), compared with 16% (95% confidence limits = 0-34%) for those in a neighborhood with zero outlets. This moderating effect of alcohol outlet density was not explained by the state of residence, population density, or neighborhood sociodemographic characteristics. The results suggest that living in a neighborhood with many alcohol outlets may be especially high-risk for those individuals who are genetically predisposed to frequently drink.

  15. The roles of outlet density and norms in alcohol use disorder

    OpenAIRE

    Ahern, J; Balzer, L; Galea, S

    2015-01-01

    © 2015 Elsevier Ireland Ltd. Background: Alcohol outlet density and norms shape alcohol consumption. However, due to analytic challenges we do not know: (a) if alcohol outlet density and norms also shape alcohol use disorder, and (b) whether they act in combination to shape disorder. Methods: We applied a new targeted minimum loss-based estimator for rare outcomes (rTMLE) to a general population sample from New York City (N= 4000) to examine the separate and combined relations of neighborhood...

  16. The association of alcohol outlet density with illegal underage adolescent purchasing of alcohol.

    Science.gov (United States)

    Rowland, Bosco; Toumbourou, John W; Livingston, Michael

    2015-02-01

    Although previous studies have suggested that greater community densities of alcohol sales outlets are associated with greater alcohol use and problems, the mechanisms are unclear. The present study examined whether density was associated with increased purchasing of alcohol by adolescents younger than the legal purchase age of 18 in Australia. The number of alcohol outlets per 10,000 population was identified within geographic regions in Victoria, Australia. A state-representative student survey (N = 10,143) identified adolescent reports of purchasing alcohol, and multilevel modeling was then used to predict the effects for different densities of outlet types (packaged, club, on-premise, general, and overall). Each extra sales outlet per 10,000 population was associated with a significant increase in the risk of underage adolescent purchasing. The strongest effect was for club density (odds ratio = 1.22) and packaged (takeaway) outlet density (odds ratio = 1.12). Males, older children, smokers, and those with substance-using friends were more likely to purchase alcohol. One mechanism by which alcohol sales outlet density may influence population rates of alcohol use and related problems is through increasing the illegal underage purchasing of alcohol. Copyright © 2015 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  17. Development of a solenoid actuated planar valveless micropump with single and multiple inlet-outlet arrangements

    Science.gov (United States)

    Kumar, N.; George, D.; Sajeesh, P.; Manivannan, P. V.; Sen, A. K.

    2016-07-01

    We report a planar solenoid actuated valveless micropump with multiple inlet-outlet configurations. The self-priming characteristics of the multiple inlet-multiple outlet micropump are studied. The filling dynamics of the micropump chamber during start-up and the effects of fluid viscosity, voltage and frequency on the dynamics are investigated. Numerical simulations for multiple inlet-multiple outlet micropumps are carried out using fluid structure algorithm. With DI water and at 5.0 Vp-p, 20 Hz frequency, the two inlet-two outlet micropump provides a maximum flow rate of 336 μl min-1 and maximum back pressure of 441 Pa. Performance characteristics of the two inlet-two outlet micropump are studied for aqueous fluids of different viscosity. Transport of biological cell lines and diluted blood samples are demonstrated; the flow rate-frequency characteristics are studied. Viability of cells during pumping with multiple inlet multiple outlet configuration is also studied in this work, which shows 100% of cells are viable. Application of the proposed micropump for simultaneous pumping, mixing and distribution of fluids is demonstrated. The proposed integrated, standalone and portable micropump is suitable for drug delivery, lab-on-chip and micro-total-analysis applications.

  18. Numerical simulation of dynamic flow characteristics in a centrifugal water pump with three-vaned diffuser

    Directory of Open Access Journals (Sweden)

    Zhi-Jun Shuai

    2015-08-01

    Full Text Available The complex three-dimensional turbulent flow field in a centrifugal water pump with three asymmetrical diffusers was numerically simulated. The characteristics of pressure and force fluctuations inside the model pump were investigated. Fast Fourier transformation was performed to obtain the spectra of pressure and force fluctuations. It indicates that the dominant frequency of pressure fluctuations is the blade passing frequency in all the sub-domains inside the pump and the first blade passing frequency energy (first order of blade passing frequency is the most significant. The dominant frequency of pressure fluctuations at the location of diffuser outlet is featured by low frequency (less than 1 Hz, which may be due to the locally generated eddy structures. Besides, the dominant frequency force fluctuations on the impeller blades are also the blade passing frequency. The existence of the three asymmetrical diffusers has damping effect on the pressure fluctuation amplitude and energy amplitude of pressure fluctuations in the diffuser domain dramatically, which indicates that the diffusers can effectively control the hydraulically excited vibration in the pump. Besides, the prediction of the dominant frequency of pressure fluctuations inside the pump can help to utilize the pump effectively and to extend the pump life. The main findings of this work can provide prediction of the pump performance and information for further optimal design of centrifugal pumps as well.

  19. 3D shape optimization of fan vanes for multiple operating regimes subject to efficiency and noise-related excellence criteria and constraints

    Directory of Open Access Journals (Sweden)

    Ivo Marinić-Kragić

    2016-01-01

    Full Text Available Fully generic 3D shapes of centrifugal roof fan vanes are explored based on a custom-developed numerical workflow with the ability to vary the vane 3D shape by manipulating the control points of parametric surfaces and change the number of vanes and rotation speed. An excellence formulation is based on design flow efficiency, multi-regime operational conditions and noise criteria for various cases, including multi-objective optimization. Multiple cases of optimization demonstrate the suitability of customized and individualized fan designs for specific working environments according to the selected excellence criteria. Noise analysis is considered as an additional decision-making tool for cases where multiple solutions of equal efficiency are generated and as an additional criteria for multi-objective optimization. The 3D vane shape enables further gains in efficiency compared to 2D shape optimization, while multi-objective optimization with noise as an additional criterion shows potential to greatly reduce the roof fan noise with only small losses in efficiency. The developed workflow which comprises (i a 3D parametric shape modeler, (ii an evolutionary optimizer and (iii a computational fluid dynamics (CFD simulator can be viewed as an integral tool for optimizing the designs of roof fans under custom conditions.

  20. Achieving more efficient operation of the nozzle vane and rotor blade rows of gas turbines through using nonaxisymmetric end wall surfaces of interblade channels

    Science.gov (United States)

    Inozemtsev, A. A.; Samokhvalov, N. Yu.; Tikhonov, A. S.

    2012-09-01

    Results from a numerical study of three versions of the end-wall generatrix of the interblade channel used in the second-stage nozzle vanes of a prospective engine's turbine are presented. Recommendations for designing nonaxisymmetric end-wall surfaces are suggested based on the obtained data.

  1. Effect of turbulence intensity on cross-injection film cooling at a stepped or smooth endwall of a gas turbine vane passage.

    Science.gov (United States)

    Wu, Pey-Shey; Tsai, Shen-Ta; Jhuo, Yue-Hua

    2014-01-01

    This study is concerned with a film cooling technique applicable to the protection of the endwalls of a gas turbine vane. In the experiments, cross-injection coolant flow from two-row, paired, inclined holes with nonintersecting centerlines was utilized. The test model is a scaled two-half vane. The levels of turbulence intensity used in the experiments are T.I. = 1.8%, 7%, and 12%. Other parameters considered in the film cooling experiments include three inlet Reynolds numbers (9.20 × 10(4), 1.24 × 10(5), and 1.50 × 10(5)), three blowing ratios (0.5, 1.0, and 2.0), and three endwall conditions (smooth endwall and stepped endwall with forward-facing or backward-facing step). Thermochromic liquid crystal (TLC) technique with steady-state heat transfer experiments was used to obtain the whole-field film cooling effectiveness. Results show that, at low turbulence intensity, increasing Reynolds number decreases the effectiveness in most of the vane passage. There is no monotonic trend of influence by Reynolds number at high turbulence intensity. The effect of blowing ratio on the effectiveness has opposite trends at low and high turbulence levels. Increasing turbulent intensity decreases the effectiveness, especially near the inlet of the vane passage. With a stepped endwall, turbulence intensity has only mild effect on the film cooling effectiveness.

  2. Effect of Turbulence Intensity on Cross-Injection Film Cooling at a Stepped or Smooth Endwall of a Gas Turbine Vane Passage

    Directory of Open Access Journals (Sweden)

    Pey-Shey Wu

    2014-01-01

    Full Text Available This study is concerned with a film cooling technique applicable to the protection of the endwalls of a gas turbine vane. In the experiments, cross-injection coolant flow from two-row, paired, inclined holes with nonintersecting centerlines was utilized. The test model is a scaled two-half vane. The levels of turbulence intensity used in the experiments are T.I.=1.8%, 7%, and 12%. Other parameters considered in the film cooling experiments include three inlet Reynolds numbers (9.20×104 , 1.24×105, and  1.50×105, three blowing ratios (0.5, 1.0, and 2.0, and three endwall conditions (smooth endwall and stepped endwall with forward-facing or backward-facing step. Thermochromic liquid crystal (TLC technique with steady-state heat transfer experiments was used to obtain the whole-field film cooling effectiveness. Results show that, at low turbulence intensity, increasing Reynolds number decreases the effectiveness in most of the vane passage. There is no monotonic trend of influence by Reynolds number at high turbulence intensity. The effect of blowing ratio on the effectiveness has opposite trends at low and high turbulence levels. Increasing turbulent intensity decreases the effectiveness, especially near the inlet of the vane passage. With a stepped endwall, turbulence intensity has only mild effect on the film cooling effectiveness.

  3. Evidence for validity of five secondary data sources for enumerating retail food outlets in seven American Indian Communities in North Carolina

    Science.gov (United States)

    2012-01-01

    Background Most studies on the local food environment have used secondary sources to describe the food environment, such as government food registries or commercial listings (e.g., Reference USA). Most of the studies exploring evidence for validity of secondary retail food data have used on-site verification and have not conducted analysis by data source (e.g., sensitivity of Reference USA) or by food outlet type (e.g., sensitivity of Reference USA for convenience stores). Few studies have explored the food environment in American Indian communities. To advance the science on measuring the food environment, we conducted direct, on-site observations of a wide range of food outlets in multiple American Indian communities, without a list guiding the field observations, and then compared our findings to several types of secondary data. Methods Food outlets located within seven State Designated Tribal Statistical Areas in North Carolina (NC) were gathered from online Yellow Pages, Reference USA, Dun & Bradstreet, local health departments, and the NC Department of Agriculture and Consumer Services. All TIGER/Line 2009 roads (>1,500 miles) were driven in six of the more rural tribal areas and, for the largest tribe, all roads in two of its cities were driven. Sensitivity, positive predictive value, concordance, and kappa statistics were calculated to compare secondary data sources to primary data. Results 699 food outlets were identified during primary data collection. Match rate for primary data and secondary data differed by type of food outlet observed, with the highest match rates found for grocery stores (97%), general merchandise stores (96%), and restaurants (91%). Reference USA exhibited almost perfect sensitivity (0.89). Local health department data had substantial sensitivity (0.66) and was almost perfect when focusing only on restaurants (0.91). Positive predictive value was substantial for Reference USA (0.67) and moderate for local health department data (0

  4. The impact of the tobacco retail outlet environment on adult cessation and differences by neighborhood poverty.

    Science.gov (United States)

    Cantrell, Jennifer; Anesetti-Rothermel, Andrew; Pearson, Jennifer L; Xiao, Haijun; Vallone, Donna; Kirchner, Thomas R

    2015-01-01

    This study examined the impact of tobacco retail outlets on cessation outcomes over time among non-treatment-seeking smokers and assessed differences by neighborhood poverty and individual factors. Observational longitudinal cohort study using geospatial data. We used generalized estimating equations to examine cessation outcomes in relation to the proximity and density of tobacco retail outlets near the home. Eight large Designated Media Areas across the United States. A total of 2377 baseline smokers followed over three waves from 2008 to 2010. Outlet addresses were identified through North American Industry Classification System codes and proximity and density measures were constructed for each participant at each wave. Outcomes included past 30-day abstinence and pro-cessation attitudes. Smokers in high poverty census tracts living between 500 m and 1.9 km from an outlet were over two times more likely to be abstinent than those living fewer than 500 m from an outlet (P < 0.05). Density within 500 m of home was associated with reduced abstinence [odds ratio (OR) = 0.94; confidence interval (CI) = 0.90, 0.98) and lower pro-cessation attitudes (Coeff = -0.07, CI = -0.10, -0.03) only in high poverty areas. In low poverty areas, density within 500 m was associated with greater pro-cessation attitudes (OR = 0.06; CI = 0.01, 0.12). Gender, education and heaviness of smoking did not moderate the impact of outlet proximity and density on cessation outcomes. In the United States, density of tobacco outlets within 500 m of the home residence appears to be negatively associated with smoking abstinence and pro-cessation attitudes only in poor areas. © 2014 Society for the Study of Addiction.

  5. The premises is the premise: understanding off- and on-premises alcohol sales outlets to improve environmental alcohol prevention strategies.

    Science.gov (United States)

    Chinman, Matthew; Burkhart, Q; Ebener, Patricia; Fan, Cha-Chi; Imm, Pamela; Osilla, Karen Chan; Paddock, Susan M; Wright, Annie

    2011-06-01

    Environmental strategies to prevent the misuse of alcohol among youth--e.g., use of public policies to restrict minors' access to alcohol--have been shown to reduce underage drinking. However, implementation of policy changes often requires public and private partnerships. One way to support these partnerships is to better understand the target of many of the environmental strategies, which is the alcohol sales outlet. Knowing more about how off-premises outlets (e.g., liquor and convenience stores) and on-premises outlets (e.g., bars and restaurants) are alike and different could help community-based organizations better tailor, plan, and implement their environmental strategies and strengthen partnerships between the public and commercial sectors. We conducted a survey of managerial or supervisory staff and/or owners of 336 off- and on-premises alcohol outlets in six counties in South Carolina, comparing these two outlet types on their preferences regarding certain alcohol sales practices, beliefs toward underage drinking, alcohol sales practices, and outcomes. Multilevel logistic regression showed that while off- and on-premises outlets did have many similarities, off-premises outlets appear to engage in more practices designed to prevent sales of alcohol to minors than on-premises outlets. The relationship between certain Responsible Beverage Service (RBS) practices and outcomes varied by outlet type. This study furthers the understanding of the differences between off- and on-premises alcohol sales outlets and offers options for increasing and tailoring environmental prevention efforts to specific settings.

  6. Proximity to Fast-Food Outlets and Supermarkets as Predictors of Fast-Food Dining Frequency.

    Science.gov (United States)

    Athens, Jessica K; Duncan, Dustin T; Elbel, Brian

    2016-08-01

    This study used cross-sectional data to test the independent relationship of proximity to chain fast-food outlets and proximity to full-service supermarkets on the frequency of mealtime dining at fast-food outlets in two major urban areas, using three approaches to define access. Interactions between presence of a supermarket and presence of fast-food outlets as predictors of fast-food dining were also tested. Residential intersections for respondents in point-of-purchase and random-digit-dial telephone surveys of adults in Philadelphia, PA, and Baltimore, MD, were geocoded. The count of fast-food outlets and supermarkets within quarter-mile, half-mile, and 1-mile street network buffers around each respondent's intersection was calculated, as well as distance to the nearest fast-food outlet and supermarket. These variables were regressed on weekly fast-food dining frequency to determine whether proximity to fast food and supermarkets had independent and joint effects on fast-food dining. The effect of access to supermarkets and chain fast-food outlets varied by study population. Among telephone survey respondents, supermarket access was the only significant predictor of fast-food dining frequency. Point-of-purchase respondents were generally unaffected by proximity to either supermarkets or fast-food outlets. However, ≥1 fast-food outlet within a 1-mile buffer was an independent predictor of consuming more fast-food meals among point-of-purchase respondents. At the quarter-mile distance, ≥1 supermarket was predictive of fewer fast-food meals. Supermarket access was associated with less fast-food dining among telephone respondents, whereas access to fast-food outlets were associated with more fast-food visits among survey respondents identified at point-of-purchase. This study adds to the existing literature on geographic determinants of fast-food dining behavior among urban adults in the general population and those who regularly consume fast food. Copyright

  7. Guided labworks

    DEFF Research Database (Denmark)

    Jacobsen, Lærke Bang

    For the last 40 years physics education research has shown poor learning outcomes of guided labs. Still this is found to be a very used teaching method in the upper secodary schools. This study explains the teacher's choice of guided labs throught the concept of redesign as obstacle dislodgement...

  8. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...

  9. Communicating Ebola through social media and electronic news media outlets: A cross-sectional study.

    Science.gov (United States)

    Househ, Mowafa

    2016-09-01

    Social media and electronic news media activity are an important source of information for the general public. Yet, there is a dearth of research exploring the use of Twitter and electronic news outlets during significant worldly events such as the recent Ebola Virus scare. The purpose of this article is to investigate the use of Twitter and electronic news media outlets in communicating Ebola Virus information. A cross-sectional survey of Twitter data and Google News Trend data from 30 September till 29 October, 2014 was conducted. Between 30 September and 29 October, there were approximately 26 million tweets (25,925,152) that contained the word Ebola. The highest number of correlated activity for Twitter and electronic news outlets occurred on 16 October 2014. Other important peaks in Twitter data occurred on 1 October, 6 October, 8 October, and 12 October, 2014. The main influencers of the Twitter feeds were news media outlets. The study reveals a relationship between electronic news media publishing and Twitter activity around significant events such as Ebola. Healthcare organizations should take advantage of the relationship between electronic news media and trending events on social media sites such as Twitter and should work on developing social media campaigns in co-operation with leading electronic news media outlets (e.g. CNN, Yahoo, Reuters) that can have an influence on social media activity. © The Author(s) 2015.

  10. Examining the interaction between food outlets and outdoor food advertisements with primary school food environments.

    Science.gov (United States)

    Walton, Mat; Pearce, Jamie; Day, Peter

    2009-09-01

    Schools are commonly seen as a site of intervention to improve children's nutrition, and prevent excess weight gain. Schools may have limited influence over children's diets; however, with home and community environments also exerting an influence within schools. This study considered the environment of food outlets and outdoor food advertisements surrounding four case study primary schools in New Zealand, and the impact of that external environment on within-school food environments. The shortest travel route between school and home addresses, and the number of food outlets and advertisements passed on that route, was calculated for each student. Interviews with school management were conducted. The schools with a higher percentage of students passing food outlets and advertisements considered that their presence impacted on efforts within schools to improve the food environment. Limiting students' exposure to food outlets and outdoor food adverts through travel route planning, reducing advertising, or limiting the location of food outlets surrounding schools could be explored as intervention options to support schools in promoting nutrition.

  11. Validation of commercial business lists as a proxy for licensed alcohol outlets.

    Science.gov (United States)

    Carlos, Heather A; Gabrielli, Joy; Sargent, James D

    2017-05-19

    Studies of retail alcohol outlets are restricted to regions due to lack of U.S. national data. Commercial business lists (BL) offer a possible solution, but no data exists to determine if BLs could serve as an adequate proxy for license data. This paper compares geospatial measures of alcohol outlets derived from a commercial BL with license data for a large US state. We validated BL data as a measure of off-premise alcohol outlet density and proximity compared to license data for 5528 randomly selected California residential addresses. We calculated three proximity measures (Euclidean distance, road network travel time and distance) and two density measures (kernel density estimation and the count within a 2-mile radius) for each dataset. The data was acquired in 2015 and processed and analyzed in 2015 and 2016. Correlations and reliabilities between density (correlation 0.98; Cronbach's α 0.97-0.99) and proximity (correlations 0.77-0.86; α 0.87-0.92) measures were high. For proximity, BL data matched license in 55-57% of addresses, overstated distance in 19%, and understated in 24-26%. BL data can serve as a reliable proxy for licensed alcohol outlets, thus extending the work that can be performed in studies on associations between retail alcohol outlets and drinking outcomes.

  12. Geocoding routinely collected administrative data to measure access to alcohol outlets in Wales

    Directory of Open Access Journals (Sweden)

    Richard Fry

    2017-04-01

    All authorities were able to provide an actual or approximate license issue date, allowing us to summarise the number of outlets annually. Several authorities were unable to provide precise outlet closure dates, so the date of the last interaction with the outlet was used to generate an approximate end date. One-half of the unitary authorities were able to provide the On/Off sales status of outlets, and 9 were able to provide opening hours. From these data we were able to geocode 53% (range 28% to 72% by local authority using GIS, the remaining 47% were matched using Google products to verify and extract a precise geographic location. Conclusions The collation and processing of retrospective alcohol outlet data was successfully completed to enable the building of a longitudinal exposure dataset. There was considerable variation between the unitary authorities in the quality of address data, and data related to the availability of alcohol, for example opening hours. The lack of address structure required us to devise a manual address matching process to capture the addresses that could not be geocoded. To aid future data linkage based evaluations to provide policy evidence in a timely manner, local government datasets should use standardised data fields, including addresses and Point-of-Capture address verification.

  13. Bursting Events in Pressure Flushing with Expanding Bottom Outlet Channel within Dam Reservoir

    Directory of Open Access Journals (Sweden)

    soheila Tofighi

    2017-01-01

    Full Text Available Introduction: Currently, large dams in the world, due to the high amount of sediments in the reservoir, especially around the intake, have operational problems. One of the solutions for this problem is pressure flushing. In this type of flushing, a mixture of water and sediment is removed from bottom outlets form dam reservoir and a funnel shaped crater is created in the vicinity of the outlet opening. In laboratory experiments carried out in this study, pressure flushing with the expansion of bottom outlet within the reservoir and its statistical analysis of bursting events were investigated. The structure of the turbulent flow is not fully understood due to their complexity and random nature. Klein et al. Introduced the turbulence bursting in this kind of flow and Nezo and Nakagora suggested that the events resulting from turbulence bursting has a significant effect of transferring the sediment particles. Materials and Methods: For the purposes of this study, the experiments were conducted with a physical model with 7m length, 1.4m width, and 1.5m height, consisting of three parts namely the inlet of the model, the main reservoir, and settling basin. The main reservoir of the model was 5m long and the sediments were placed within this part of the model. The sediment particles were non-cohesive silica with uniform size and with median diameter (d50 1.15mm and geometrics standard deviation (σg 1.37. Experiments carried out with different discharges and water depths above the bottom outlet in different expansion size of outlet channel in constant sediment level of 20cm above the center of the outlet channel. The model was slowly filled with water until the water surface elevation reached to a desired level. The bottom outlet was manually opened, after a while sedimentwere discharged with the water flow in very high concentrations through the outlet channel (sudden discharge and a funnel shaped crater was formed in front of it. After the run of

  14. KORELASI PENGGUNAAN BAHASA INGGRIS DALAM PENAMAAN FACTORY OUTLET (FO DI BANDUNG TERHADAP KEPUTUSAN PEMBELIAN

    Directory of Open Access Journals (Sweden)

    Gartika Rahmasari

    2016-03-01

        Abstrak - Bahasa Inggris merupakan bahasa yang memiliki prestise atau kedudukan yang tinggi, bahkan di Indonesia yang memiliki bahasa Indonesia sebagai bahasa nasional. Bahasa Inggris sebagai bahasa internasional mendapatkan apresiasi lebih tinggi dibandingkan dengan bahasa Indonesia, khususnya di bidang pariwisata. Bandung sebagai salah satu tujuan pariwisata, khususnya wisata kuliner dan tujuan belanja, tidak terkecuali mendapat pengaruh yang besar dalam hal penggunaan bahasa Inggris. Hal ini dapat dilihat dari penggunaan sejumlah nama Factory Outlet yang ada di Bandung, yang hampir sebagian besar menggunakan bahasa Ingris atau serapan bahasa Inggris sebagai “brand” atau nama yang digunakan oleh Factory Outlet yang tersebar di seluruh Bandung. Jurnal ini merupakan study literatur yang meneliti tentang hubungan penggunaan bahasa Asing dalam nama Factory Outlet  (FO terhadap keputusan pembelian. Yang menjadi responden yang diteliti dalam penelitian ini adalah mahasiswa Ilmu Komunikasi, Universitas Telkom sebanyak 55 responden, dengan rentang usia 17-20 tahun. Dari hasil penelitian, diketahui bahwa secara umum, penggunaan bahasa Inggris dalam penamaan Factory Outlet (FO mempengaruhi keputusan responden untuk berbelanja ke FO tersebut.   Kata Kunci: Keputusan Pembelian, Factory Outlet, FO, Bahasa Inggris.

  15. Increasing Access to Subsidized Artemisinin-based Combination Therapy through Accredited Drug Dispensing Outlets in Tanzania

    Directory of Open Access Journals (Sweden)

    Gabra Michael

    2011-06-01

    Full Text Available Abstract Background In Tanzania, many people seek malaria treatment from retail drug sellers. The National Malaria Control Program identified the accredited drug dispensing outlet (ADDO program as a private sector mechanism to supplement the distribution of subsidized artemisinin-based combination therapies (ACTs from public facilities and increase access to the first-line antimalarial in rural and underserved areas. The ADDO program strengthens private sector pharmaceutical services by improving regulatory and supervisory support, dispenser training, and record keeping practices. Methods The government's pilot program made subsidized ACTs available through ADDOs in 10 districts in the Morogoro and Ruvuma regions, covering about 2.9 million people. The program established a supply of subsidized ACTs, created a price system with a cost recovery plan, developed a plan to distribute the subsidized products to the ADDOs, trained dispensers, and strengthened the adverse drug reactions reporting system. As part of the evaluation, 448 ADDO dispensers brought their records to central locations for analysis, representing nearly 70% of ADDOs operating in the two regions. ADDO drug register data were available from July 2007-June 2008 for Morogoro and from July 2007-September 2008 for Ruvuma. This intervention was implemented from 2007-2008. Results During the pilot, over 300,000 people received treatment for malaria at the 448 ADDOs. The percentage of ADDOs that dispensed at least one course of ACT rose from 26.2% during July-September 2007 to 72.6% during April-June 2008. The number of malaria patients treated with ACTs gradually increased after the start of the pilot, while the use of non-ACT antimalarials declined; ACTs went from 3% of all antimalarials sold in July 2007 to 26% in June 2008. District-specific data showed substantial variation among the districts in ACT uptake through ADDOs, ranging from ACTs representing 10% of all antimalarial sales

  16. Heat transfer from the evaporator outlet to the charge of thermostatic expansion valves

    DEFF Research Database (Denmark)

    Langmaack, Lasse Nicolai; Knudsen, Hans-Jørgen Høgaard

    2006-01-01

    outlet with a special mounting strap. The heat transfer is quite complex because it takes place both directly through the contact points between bulb and pipe and indirectly through the mounting strap The TXV has to react to temperature changes at the evaporator outlet. Therefore, the dynamic behavior...... of the valve (and thereby the whole refrigeration system) depends greatly on the heat transfer between the evaporator outlet tube and the charge in the bulb. In this paper a model for the overall heat transfer between the pipe and the charge is presented. Geometrical data and material properties have been kept...... been found to predict the time constant for the temperature development in the bulb within 1-10 %. Furthermore it has been found that app. 20% of the heat transfer takes place trough the mounting strap....

  17. The influence of cooling water outlet of the Ringhals power plant on the coastal fish colony

    International Nuclear Information System (INIS)

    Neuman, E.

    1988-03-01

    Fish abundance has been monitored with fyke nets in 1976-1987 at the cooling-water outlet from the Ringhals nuclear power plant at the Swedish west coast and in a reference area. Judging from the dependence of the catches on temperature, Myoxocephalus scorpius, Zoarces viviparus, Gadus morhua and Platichtys flesus can be classified as cold-water species and Symphodus melops, Ctenolabrus rupestris, Carci nus maenas and Anguilla anguilla as warm-water species. As a rule the warm-water species were more and the cold-water fishes less abundant in the outlet area than in the reference area. The catch of the economically important Anguilla was about three times greater in the heated area. A lower abundance than expected of Ctenolabrus and Myoxocephalus at the outlet may be caused by a loss of eggs and larvae in the cooling-water system. (author)

  18. Ayurvedic medicine in Mauritius: Profile of Ayurvedic outlet, use, sale, distribution, regulation and importation.

    Science.gov (United States)

    Elaheebocus, Naailah; Mahomoodally, M Fawzi

    2017-02-02

    Ayurvedic medicine (AM) is a legalised alternative traditional medical system in the multicultural tropical island of Mauritius. A panoply of Ayurvedic specialised shops/centres involved in the provision of Ayurvedic services hereafter termed as 'outlets' operates in different regions of the island and is extensively exploited by a significant number of Mauritians. Nonetheless, there is currently no study geared towards studying the status of AM and profile of Ayurvedic outlets in Mauritius and there is undoubtedly a dearth of standardized regulatory framework governing the practice of AM in Mauritius. The present study attempts to study the profile of Ayurvedic outlets, sale, distribution, regulation and importation of AM in Mauritius. To evaluate the characteristics profile of Ayurvedic shops/clinics/pharmacies/centres, to document common Ayurvedic products used in the treatment and management of diseases, and to analyse existing regulatory control of AM in Mauritius. Ayurvedic outlets were identified using a random approach. Once permission granted, outlets were visited where face-to-face interviews with Ayurvedic practitioners/directors/dispensers were undertaken using a semi-structured questionnaire. The characteristics of the outlets with respect to the type of business registration, procurement and dispensing of products, registration and qualification of personnels employed amongst others were studied. The International Classification of Diseases (ICD) 10 was used to classify common AM dispensed to patients. Additionally, information was sought from local authorities pertaining to existing legislation governing the importation and regulation of AM in Mauritius. A total of 16 Ayurvedic outlets ('pharmacies' (n=3), clinics (n=2), shops (n=5) and centres (n=6)) was surveyed. Six outlets dispensed AM strictly on prescription only after consultation with an onsite full-time employed registered Ayurvedic practitioner. Seven outlets offered AM both on prescription

  19. Fruit and vegetable intake in adolescents: SES and exposure to supermarkets and fast food outlets

    DEFF Research Database (Denmark)

    Svastisalee, Chalida; Holstein, Bjørn Evald; Due, Pernille

    backgrounds. Methods Data from the Health Behavior in School Aged Children Study (n = 6,034) were supplemented with geocoded information regarding supermarkets and fast food outlets, 300 meters from each school (n = 80). We used multilevel logistic regression to examine the relationship between infrequent...... fruit and vegetable intake and supermarket and fast food outlet concentration, stratifying by levels of family social class. Results Examining supermarket exposure alone, children from low social class backgrounds had the greatest odds of infrequent vegetable (OR = 1.50; CI: 1.03-2.20) and fruit (OR = 1.......43;CI: 1.06-1.93) intake, attending schools with low concentration of supermarkets. Children from low social class families attending schools with high fast food outlet and low supermarket concentration had the greatest odds of infrequent vegetable (OR = 1.79;CI: 0.99-3.21) and fruit (OR = 1.59; CI: 1...

  20. Gastric diverticulum causing gastric outlet obstruction in the setting of duodenal atresia

    Directory of Open Access Journals (Sweden)

    Devashis Mukherjee

    2018-04-01

    Full Text Available Duodenal obstruction due to duodenal atresia occurs in 1 in 10,000 live births and is the most common type of intestinal obstruction in neonates [1–3]. Gastric outlet obstruction in the newborn period from causes other than hypertrophic pyloric stenosis is very uncommon [3]. Potential etiologies include gastric volvulus, antral web, and duplication cysts. Gastric diverticula in the infant is even more rare, with only a few case reports published, and only one describes a gastric diverticulum in the presence of a duodenal atresia [4–8]. In this report, we describe the first case of a gastric outlet obstruction due to a gastric diverticulum in the presence of duodenal atresia. Keywords: Duodenal atresia, Gastric diverticulum, Gastric outlet obstruction

  1. Malignant gastric outlet obstruction managed by endoscopic stenting: a prospective single-centre study

    DEFF Research Database (Denmark)

    Havemann, Maria Cecilie; Adamsen, Sven; Wøjdemann, Morten

    2008-01-01

    -to-treat principle. All patients were offered endoscopic stenting. Oral intake before and after stenting was assessed using the gastric outlet obstruction score system (GOOSS). Various lengths of duodenal Hanaro(R) self-expanding nitinol stents were delivered through a therapeutic endoscope. Outcome criteria were......Objective. Endoscopic stenting for malignant gastric outlet obstruction was chosen as the primary strategy by which to palliate this complication, which is dominated by weight loss and anorexia. Advanced upper gastrointestinal tract cancers present late and life expectancy is limited. Only smaller...... multicentre studies point to endoscopic stenting as superior to surgery in terms of clinical outcome and cost. Material and methods. Forty-five consecutive patients with gastric outlet obstruction as a result of advanced upper GI-tract malignancy were enrolled in accordance with the intention...

  2. HBR guides

    CERN Document Server

    Duarte, Nancy; Dillon, Karen

    2015-01-01

    Master your most pressing professional challenges with this seven-volume set that collects the smartest best practices from leading experts all in one place. "HBR Guide to Better Business Writing" and "HBR Guide to Persuasive Presentations" help you perfect your communication skills; "HBR Guide to Managing Up and Across" and "HBR Guide to Office Politics" show you how to build the best professional relationships; "HBR Guide to Finance Basics for Managers" is the one book you'll ever need to teach you about the numbers; "HBR Guide to Project Management" addresses tough questions such as how to manage stakeholder expectations and how to manage uncertainty in a complex project; and "HBR Guide to Getting the Right Work Done" goes beyond basic productivity tips to teach you how to prioritize and focus on your work. This specially priced set of the most popular books in the series makes a perfect gift for aspiring leaders looking for trusted advice. Arm yourself with the advice you need to succeed on the job, from ...

  3. Surf zone entrainment, along-shore transport, and human health implications of pollution from tidal outlets

    Science.gov (United States)

    Grant, S. B.; Kim, J. H.; Jones, B. H.; Jenkins, S. A.; Wasyl, J.; Cudaback, C.

    2005-10-01

    Field experiments and modeling studies were carried out to characterize the surf zone entrainment and along-shore transport of pollution from two tidal outlets that drain into Huntington Beach and Newport Beach, popular public beaches in southern California. The surf zone entrainment and near-shore transport of pollutants from these tidal outlets appears to be controlled by prevailing wave conditions and coastal currents, and fine-scale features of the flow field around the outlets. An analysis of data from dye experiments and fecal indicator bacteria monitoring studies reveals that the along-shore flux of surf zone water is at least 50 to 300 times larger than the cross-shore flux of surf zone water. As a result, pollutants entrained in the surf zone hug the shore, where they travel significant distances parallel to the beach before diluting to extinction. Under the assumption that all surf zone pollution at Huntington Beach originates from two tidal outlets, the Santa Ana River and Talbert Marsh outlets, models of mass and momentum transport in the surf zone approximately capture the observed tidal phasing and magnitude of certain fecal indicator bacteria groups (total coliform) but not others (Escherichia coli and enterococci), implying the existence of multiple sources of, and/or multiple transport pathways for, fecal pollution at this site. The intersection of human recreation and near-shore pollution pathways implies that, from a human health perspective, special care should be taken to reduce the discharge of harmful pollutants from land-side sources of surface water runoff, such as tidal outlets and storm drains.

  4. Patterning of neighbourhood food outlets and longitudinal associations with children's eating behaviours.

    Science.gov (United States)

    Timperio, Anna; Crawford, David; Leech, Rebecca M; Lamb, Karen E; Ball, Kylie

    2018-06-01

    This study examined cross-sectional and prospective associations between typologies of neighbourhood food environment and dietary patterns among 10-12 year-old children. Baseline data were collected in 2003 and follow-up data in 2006 from children in Melbourne or Geelong. Parents completed a food frequency questionnaire at both time points. 'Healthful' and 'energy-dense' dietary pattern scores were computed. A Geographic Information System was used to determine the presence or absence of food outlets (cafés/restaurant; fast food; supermarkets/grocery stores; convenience store; greengrocer; and butcher, seafood or poultry retailer) within an 800 m road network buffer of home. Three typologies were identified: 1-variety of food outlets, including those selling core/fresh foods (n = 96); 2-café/restaurant and convenience (n = 160); 3-few types of outlets (n = 208). Latent class analysis was used to identify underlying unobservable typologies of neighbourhood food outlet availability. Linear mixed models were fitted to determine cross-sectional (n = 439) and longitudinal (n = 173) associations between the three identified neighbourhood typologies and each (log-transformed) dietary pattern, accounting for clustering within families and schools. There was little evidence of cross-sectional associations. The longitudinal analyses showed that compared to those with a variety of food outlets, those with few types had 25% lower scores for the healthful dietary pattern (p < 0.05) three years later. For optimal dietary patterns, availability of a variety of food outlets close to home, particularly those where core/fresh foods are available, may be important. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Catchment power and the joint distribution of elevation and travel distance to the outlet

    Directory of Open Access Journals (Sweden)

    L. S. Sklar

    2016-10-01

    Full Text Available The delivery of water, sediment, and solutes by catchments is influenced by the distribution of source elevations and their travel distances to the outlet. For example, elevation affects the magnitude and phase of precipitation, as well as the climatic factors that govern rock weathering, which influence the production rate and initial particle size of sediments. Travel distance, in turn, affects the timing of flood peaks at the outlet and the degree of sediment size reduction by wear, which affects particle size distributions at the outlet. The distributions of elevation and travel distance have been studied extensively but separately, as the hypsometric curve and width function. Yet a catchment can be considered as a collection of points, each with paired values of elevation and travel distance. For every point, the ratio of elevation to travel distance defines the mean slope for transport of mass to the outlet. Recognizing that mean slope is proportional to the average rate of loss of potential energy by water and sediment during transport to the outlet, we use the joint distribution of elevation and travel distance to define two new metrics for catchment geometry: "source-area power", and the corresponding catchment-wide integral "catchment power". We explore patterns in source-area and catchment power across three study catchments spanning a range of relief and drainage area. We then develop an empirical algorithm for generating synthetic source-area power distributions, which can be parameterized with data from natural catchments. This new way of quantifying the three-dimensional geometry of catchments can be used to explore the effects of topography on the distribution on fluxes of water, sediment, isotopes, and other landscape products passing through catchment outlets, and may provide a fresh perspective on problems of both practical and theoretical interest.

  6. Abandonment of the low level outlet structure at the McGregor South Dam

    Energy Technology Data Exchange (ETDEWEB)

    Mack, D.L; Murray, T.K. [Klohn-Crippen Consultants Ltd., Calgary, AB (Canada); Soutar, B.M. [Alberta Transportation, Edmonton, AB (Canada)

    2008-07-01

    The Carseland-Bow River Headworks (CBRH) is a major multi-purpose water delivery system, situated in southern Alberta. It supplies water to 87,000 hectares of agricultural land and several municipalities. The system was originally built starting in 1909. It consists of diversion works on the Bow River, 65 kilometres of canal, and the McGregor and Little Bow reservoirs. In the 1950s, the system was rehabilitated by the Prairie Farm Rehabilitation Administration (PFRA), and Travers Reservoir was added in 1954. In 1973, ownership and operation of the CBRH system was turned over to Alberta Environment. In 2001, Alberta Transportation implemented a major program to rehabilitate and upgrade the CBRH system. This program included increasing the capacity of the canals and structures, and upgrading the dams to meet current dam safety guidelines. The project involved raising the north and south dams, providing an auxiliary spillway to accommodate the probable maximum flood (PMF), and rehabilitating the existing reservoir inlet and low level outlet structures. This paper discussed the abandonment of the existing low level outlet structure located within the south dam. The paper discussed the existing dams and outlet structure as well as the south dam and outlet structure. The abandonment of the existing low level outlet structure was discussed in terms of general construction; demolition; upstream conduits and gatewell; and downstream conduit. Several illustrations and photographs of the dam and the demolition were presented. It was concluded that the in-place abandonment of the existing low level outlet structure at the McGregor South Dam provides significant advantages, including eliminating the need to construct and remove an extensive cofferdam within the reservoir. 6 refs., 2 tabs., 4 figs.

  7. Effects of inlet/outlet configurations on the electrostatic capture of airborne nanoparticles and viruses

    International Nuclear Information System (INIS)

    Jang, Jaesung; Akin, Demir; Bashir, Rashid

    2008-01-01

    Motivated by capture and detection of airborne biological agents in real time with a cantilever biosensor without introducing the agents into liquids, we present the effects of inlet/outlet configurations of a homemade particle collector on the electrostatic capture of airborne 100 nm diameter nanoparticles under swirling gas flows. This particle collector has three different inlet/outlet configurations: forward inlet/outlet (FO), backward inlet/outlet (BO) and straight inlet/outlet (SO) configurations. We also present the electrostatic capture of Vaccinia viruses using the same particle collector and compare these virus measurements with the nanoparticle cases. The most particles were collected in the FO configuration. The numbers of particles captured in the BO and SO configurations were close within their standard deviations. For all the three configurations tested, the number of particles captured in the center electrode C was much smaller than those captured in the other electrodes at a flow rate of 1.1 l min −1 and an applied potential of 2 kV. Using a commercial CFD code FLUENT, we also simulated the effects of the three inlet/outlet configurations on the particle capture in terms of particle trajectories, velocities and travel times. This simulation was in a good agreement with measurements that the FO configuration is the most favorable to particle capture among the tested configurations at a flow rate of 1.1 l min −1 . The effects of particle diameters on the capture will also be discussed. This collector can be used for real-time monitoring of bioaerosols along with cantilever biosensors

  8. Proximity of off-premise alcohol outlets and heavy alcohol consumption: a cohort study.

    Science.gov (United States)

    Halonen, Jaana I; Kivimäki, Mika; Virtanen, Marianna; Pentti, Jaana; Subramanian, S V; Kawachi, Ichiro; Vahtera, Jussi

    2013-09-01

    Availability of alcohol has been associated with alcohol consumption in cross-sectional studies. We examined longitudinally whether change in proximity to off-premise (i.e., no consumption on the premises) beer and liquor outlets is associated with heavy alcohol consumption. Distances from 54,778 Finnish Public Sector study participants' homes to the nearest off-premise beer and liquor outlets were calculated using Global Positioning System-coordinates. Between-individual analyses were used to study the effects of distance to the nearest outlet on heavy alcohol use, and within-individual analyses to study the effects of a change in distance on change in heavy use. Mean follow-up time in 2000-2009 was 6.8 (standard deviation 2.0) years. In a between-individual analysis, decrease from ≥500 m to alcohol use in women (odds ratio 1.23, 95% CI 1.05-1.44), but not in men. In a within-individual analysis decrease from 500 m to 0m in log-transformed continuous distance to the nearest beer outlet increased the odds of heavy alcohol consumption in women by 13% (odds ratio 1.13, 95% CI 1.01-1.27). For the corresponding change in distance to liquor outlet the increase was 3% (odds ratio 1.03, 95% CI 0.97-1.09). Change in distance from home to the nearest off-premise alcohol outlet affects the risk of heavy alcohol consumption in women. This evidence supports policies that restrict physical availability of alcohol. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Statistical Approaches Used to Assess the Equity of Access to Food Outlets: A Systematic Review.

    Science.gov (United States)

    Lamb, Karen E; Thornton, Lukar E; Cerin, Ester; Ball, Kylie

    2015-01-01

    Inequalities in eating behaviours are often linked to the types of food retailers accessible in neighbourhood environments. Numerous studies have aimed to identify if access to healthy and unhealthy food retailers is socioeconomically patterned across neighbourhoods, and thus a potential risk factor for dietary inequalities. Existing reviews have examined differences between methodologies, particularly focussing on neighbourhood and food outlet access measure definitions. However, no review has informatively discussed the suitability of the statistical methodologies employed; a key issue determining the validity of study findings. Our aim was to examine the suitability of statistical approaches adopted in these analyses. Searches were conducted for articles published from 2000-2014. Eligible studies included objective measures of the neighbourhood food environment and neighbourhood-level socio-economic status, with a statistical analysis of the association between food outlet access and socio-economic status. Fifty-four papers were included. Outlet accessibility was typically defined as the distance to the nearest outlet from the neighbourhood centroid, or as the number of food outlets within a neighbourhood (or buffer). To assess if these measures were linked to neighbourhood disadvantage, common statistical methods included ANOVA, correlation, and Poisson or negative binomial regression. Although all studies involved spatial data, few considered spatial analysis techniques or spatial autocorrelation. With advances in GIS software, sophisticated measures of neighbourhood outlet accessibility can be considered. However, approaches to statistical analysis often appear less sophisticated. Care should be taken to consider assumptions underlying the analysis and the possibility of spatially correlated residuals which could affect the results.

  10. Statistical Approaches Used to Assess the Equity of Access to Food Outlets: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Karen E. Lamb

    2015-07-01

    Full Text Available BackgroundInequalities in eating behaviours are often linked to the types of food retailers accessible in neighbourhood environments. Numerous studies have aimed to identify if access to healthy and unhealthy food retailers is socioeconomically patterned across neighbourhoods, and thus a potential risk factor for dietary inequalities. Existing reviews have examined differences between methodologies, particularly focussing on neighbourhood and food outlet access measure definitions. However, no review has informatively discussed the suitability of the statistical methodologies employed; a key issue determining the validity of study findings. Our aim was to examine the suitability of statistical approaches adopted in these analyses.MethodsSearches were conducted for articles published from 2000-2014. Eligible studies included objective measures of the neighbourhood food environment and neighbourhood-level socio-economic status, with a statistical analysis of the association between food outlet access and socio-economic status.ResultsFifty-four papers were included. Outlet accessibility was typically defined as the distance to the nearest outlet from the neighbourhood centroid, or as the number of food outlets within a neighbourhood (or buffer. To assess if these measures were linked to neighbourhood disadvantage, common statistical methods included ANOVA, correlation, and Poisson or negative binomial regression. Although all studies involved spatial data, few considered spatial analysis techniques or spatial autocorrelation.ConclusionsWith advances in GIS software, sophisticated measures of neighbourhood outlet accessibility can be considered. However, approaches to statistical analysis often appear less sophisticated. Care should be taken to consider assumptions underlying the analysis and the possibility of spatially correlated residuals which could affect the results.

  11. Factors Influencing Demand for a Producer-Owned Beef Retail Outlet

    OpenAIRE

    Lusk, Jayson L.; Cevallos, Edgar

    2004-01-01

    As the farm-to-retail price spread continues to grow, come cattle producers a beginning to consider integrating into the retail sector. Such a venture would require large investments in capital with uncertain return. This study seeks to determine the potential success of a stand-alone retail outlet selling “all natural†beef in an affluent area of Jackson, MS. Using choice-based conjoint analysis, demand for the new retail outlet is modeled as a function of the beef price at the store, dis...

  12. Isolated Cervical Rib Fracture: A Rare Etiology of Thoracic Outlet Syndrome

    Directory of Open Access Journals (Sweden)

    Rayees Ahmad Dar

    2011-01-01

    Full Text Available Isolated fracture of a cervical rib is a very rare entity and usually presents as a painless swelling or as thoracic outlet syndrome. We describe a case of a 45-year-old woman with history of fall two months back. She presented with symptoms of neurogenic thoracic outlet syndrome for one month. Isolated left cervical rib fracture was documented on X-ray cervical spine. Her fractured cervical rib was resected through a supraclavicular approach, and symptoms resolved completely in the postoperative period.

  13. Sodium steam generator within which are inlet and outlet ducts with pipe bundles in vessel

    International Nuclear Information System (INIS)

    1980-01-01

    The sodium steam generator with internal flow ducts for inlet and outlet to a vessel are provided as pipe bundles in the form of helically wound concentric layers terminating in inlet and outlet connections with chambers, characterised in that within the vessel, the pipe pieces which are connected to the pipe windings with the said vessel are arranged in substantially radially aligned rows so that each row measured in the circumferential direction at least on one side is at a spacing from the following row sufficiently large that between the rows or groups of rows an open sector is provided. (G.C.)

  14. Medication Guide

    Science.gov (United States)

    ... Size Small Text Medium Text Large Text Contrast Dark on Light Light on Dark Donate Search Menu Donate What is Glaucoma? Care ... Low Vision Resources Medication Guide Resources on the Web » See All Articles Where the Money Goes Have ...

  15. Mountain Plains Learning Experience Guide: Electrical Wiring. Course: Electrical Wiring Trim-Out.

    Science.gov (United States)

    Arneson, R.; And Others

    One of two individualized courses included in an electrical wiring curriculum, this course covers electrical materials installation for the trim-out stage. The course is comprised of five units: (1) Outlets, (2) Fixtures, (3) Switches, (4) Appliances, and (5) Miscellaneous. Each unit begins with a Unit Learning Experience Guide that gives…

  16. CFD simulation and validation of turbulent mixing in a rod bundle with vaned spacer grids based on LDV test

    International Nuclear Information System (INIS)

    Chen Xi; Li Songwei; Li Zhongchun; Du Sijia; Zhang Yu; Peng Huanhuan

    2017-01-01

    Spacer grids with mixing vanes are generally used in fuel assemblies of Pressurized Water Reactor (PWR), because that mixing vanes could enhance the lateral turbulent mixing in subchannels. Thus, heat exchangements are more efficient, and the value of departure from nucleate boiling (DNB) is greatly increased. Actually turbulent mixing is composed of two kinds of flows: swirling flow inside the subchannel and cross flow between subchannels. Swirling flow could induce mixing between hot water near the rod and cold water in the center of the subchannel, and may accelerate deviation of the bubbles from the rod surface. Besides, crossing flow help to mixing water between hot subchannels and cold subchannels, which impact relatively large flow area. As a result, how to accurately capture and how to predict the complicated mixing phenomenon are of great concernments. Recently many experimental studies has been conducted to provide detailed turbulent mixing in rod bundle, among which Laser Doppler Velocimetry method is widely used. With great development of Computational Fluid Dynamics, CFD has been validated as an analysis method for nuclear engineering, especially for single phase calculation. This paper presents the CFD simulation and validation of the turbulent mixing induced by spacer grid with mixing vanes in rod bundles. Experiment data used for validation came from 5 x 5 rod bundle test with LDV technology, which is organized by Science and Technology on Reactor System Design Technology Laboratory. A 5 x 5 rod bundle with two spacer grids were used. Each rod has dimension of 9.5 mm in outer diameter and distance between rods is 12.6 mm. Two axial bulk velocities were conducted at 3.0 m/s for high Reynolds number and 1.0 m/s for low Reynolds number. Working pressure was 1.0 bar, and temperature was about 25degC. Two different distances from the downstream of the mixing spacer grid and one from upstream were acquired. Mean axial velocities and turbulent intensities

  17. TACT1- TRANSIENT THERMAL ANALYSIS OF A COOLED TURBINE BLADE OR VANE EQUIPPED WITH A COOLANT INSERT

    Science.gov (United States)

    Gaugler, R. E.

    1994-01-01

    As turbine-engine core operating conditions become more severe, designers must develop more effective means of cooling blades and vanes. In order to design reliable, cooled turbine blades, advanced transient thermal calculation techniques are required. The TACT1 computer program was developed to perform transient and steady-state heat-transfer and coolant-flow analyses for cooled blades, given the outside hot-gas boundary condition, the coolant inlet conditions, the geometry of the blade shell, and the cooling configuration. TACT1 can analyze turbine blades, or vanes, equipped with a central coolant-plenum insert from which coolant-air impinges on the inner surface of the blade shell. Coolant-side heat-transfer coefficients are calculated with the heat transfer mode at each station being user specified as either impingement with crossflow, forced convection channel flow, or forced convection over pin fins. A limited capability to handle film cooling is also available in the program. The TACT1 program solves for the blade temperature distribution using a transient energy equation for each node. The nodal energy balances are linearized, one-dimensional, heat-conduction equations which are applied at the wall-outer-surface node, at the junction of the cladding and the metal node, and at the wall-inner-surface node. At the mid-metal node a linear, three-dimensional, heat-conduction equation is used. Similarly, the coolant pressure distribution is determined by solving the set of transfer momentum equations for the one-dimensional flow between adjacent fluid nodes. In the coolant channel, energy and momentum equations for one-dimensional compressible flow, including friction and heat transfer, are used for the elemental channel length between two coolant nodes. The TACT1 program first obtains a steady-state solution using iterative calculations to obtain convergence of stable temperatures, pressures, coolant-flow split, and overall coolant mass balance. Transient

  18. Requirements under decree 430 UJD for unit outlet and standby power supply

    International Nuclear Information System (INIS)

    Vanco, K.

    2012-01-01

    At present, the nuclear power plants are only sufficient resources, which can cover a huge demand for electricity. Concentration so huge power in one place require adequate security from the perspective lead power outlet and standby power supply of reactor unit. (Author)

  19. Alcohol outlets near schools in a midsize Romanian city. Prevalence and chararteristics

    NARCIS (Netherlands)

    van Hoof, Joris Jasper; Reijlink, Lian M.J.; van Dalen, Wim E.

    2010-01-01

    Objective: alcohol availability is one of the strongest predictors of adolescent alcohol use, and subsequent harm. Alcohol outlets near schools are an important indicator of three types of availability related to adolescent alcohol use; physical (number), economic (price), and legal (compliance with

  20. Biomass bale stack and field outlet locations assessment for efficient infield logistics

    Science.gov (United States)

    Harvested hay or biomass are traditionally baled for better handling and they are transported to the outlet for final utilization. For better management of bale logistics, producers often aggregate bales into stacks so that bale-hauling equipment can haul multiple bales for improved efficiency. Obje...

  1. Mass balance of Greenland's three largest outlet glaciers - 2000–2010

    NARCIS (Netherlands)

    Howat, I.M.; Ahn, Y.; Joughin, I.; van den Broeke, M.R.; Lenaerts, J.T.M.; Smith, B.

    2011-01-01

    Acceleration of Greenland's three largest outlet glaciers, Helheim, Kangerdlugssuaq and Jakobshavn Isbræ, accounted for a substantial portion of the ice sheet's mass loss over the past decade. Rapid changes in their discharge, however, make their cumulative mass-change uncertain. We derive monthly

  2. Benefits and limitations of animal models in partial bladder outlet obstruction for translational research.

    Science.gov (United States)

    Kitta, Takeya; Kanno, Yukiko; Chiba, Hiroki; Higuchi, Madoka; Ouchi, Mifuka; Togo, Mio; Moriya, Kimihiko; Shinohara, Nobuo

    2018-01-01

    The functions of the lower urinary tract have been investigated for more than a century. Lower urinary tract symptoms, such as incomplete bladder emptying, weak urine stream, daytime urinary frequency, urgency, urge incontinence and nocturia after partial bladder outlet obstruction, is a frequent cause of benign prostatic hyperplasia in aging men. However, the pathophysiological mechanisms have not been fully elucidated. The use of animal models is absolutely imperative for understanding the pathophysiological processes involved in bladder dysfunction. Surgical induction has been used to study lower urinary tract functions of numerous animal species, such as pig, dog, rabbit, guinea pig, rat and mouse, of both sexes. Several morphological and functional modifications under partial bladder outlet obstruction have not only been observed in the bladder, but also in the central nervous system. Understanding the changes of the lower urinary tract functions induced by partial bladder outlet obstruction would also contribute to appropriate drug development for treating these pathophysiological conditions. In the present review, we discuss techniques for creating partial bladder outlet obstruction, the characteristics of several species, as well as issues of each model, and their translational value. © 2017 The Japanese Urological Association.

  3. Method for determining the outlet temperature of fuel assemblies unsupplied with thermometer in WWER-440 reactors

    International Nuclear Information System (INIS)

    Miko, S.; Kalya, Z.; Hamvas, I.

    1987-09-01

    The paper outlines a method for the evaluation of the outlet temperatures of fuel assemblies unsupplied with thermometer in WWER-440 reactors. The process is based on interpolation of directly measured assembly temperatures. A quantitative comparison of the errors of described algorithm to those of standard plant-computer interpolation rutine is also presented. (author)

  4. A hydrologic regression sediment-yield model for two ungaged watershed outlet stations in Africa

    International Nuclear Information System (INIS)

    Moussa, O.M.; Smith, S.E.; Shrestha, R.L.

    1991-01-01

    A hydrologic regression sediment-yield model was established to determine the relationship between water discharge and suspended sediment discharge at the Blue Nile and the Atbara River outlet stations during the flood season. The model consisted of two main submodels: (1) a suspended sediment discharge model, which was used to determine suspended sediment discharge for each basin outlet; and (2) a sediment rating model, which related water discharge and suspended sediment discharge for each outlet station. Due to the absence of suspended sediment concentration measurements at or near the outlet stations, a minimum norm solution, which is based on the minimization of the unknowns rather than the residuals, was used to determine the suspended sediment discharges at the stations. In addition, the sediment rating submodel was regressed by using an observation equations procedure. Verification analyses on the model were carried out and the mean percentage errors were found to be +12.59 and -12.39, respectively, for the Blue Nile and Atbara. The hydrologic regression model was found to be most sensitive to the relative weight matrix, moderately sensitive to the mean water discharge ratio, and slightly sensitive to the concentration variation along the River Nile's course

  5. 7 CFR 987.56 - Outlets for utility and cull dates.

    Science.gov (United States)

    2010-01-01

    ..., utility dates and cull dates may be disposed of without inspection, but only in feed, non-table syrup... 7 Agriculture 8 2010-01-01 2010-01-01 false Outlets for utility and cull dates. 987.56 Section 987... DATES PRODUCED OR PACKED IN RIVERSIDE COUNTY, CALIFORNIA Order Regulating Handling Disposition of Other...

  6. Positioning invasive versus noninvasive urodynamics in the assessment of bladder outlet obstruction

    NARCIS (Netherlands)

    Arnolds, Michiel; Oelke, Matthias

    2009-01-01

    Purpose of review To provide evidence of promising tests to noninvasively diagnose bladder outlet obstruction (800) in men with benign prostatic hyperplasia. Recent findings Pressure-flow studies are usually performed to prove BOO prior to prostatectomy. However, pressure-flow studies are invasive,

  7. Effect of short-term outlet obstruction on rat bladder nerve density and contractility

    NARCIS (Netherlands)

    Barendrecht, M. M.; Chichester, P.; Michel, M. C.; Levin, R. M.

    2007-01-01

    1 The present study was designed to investigate the relationship between innervation density and contractile responses to field stimulation and exogenous agonists at early time points after induction of bladder outlet obstruction (BOO) in rats. 2 When compared with sham-operated animals, 1, 3 and 7

  8. The Effect of Bladder Outlet Obstruction on alpha(1)- and beta-Adrenoceptor Expression and Function

    NARCIS (Netherlands)

    Barendrecht, Maurits M.; Frazier, Elfaridah P.; Vrydag, Wim; Alewijnse, Astrid E.; Peters, Stephan L. M.; Michel, Martin C.

    2009-01-01

    Aims: To explore possible changes in expression and/or function of alpha(1)- and beta-adrenoceptor subtypes as a cause for bladder dysfunction in a rat model of bladder outlet obstruction (BOO). Methods: BOO was induced in rats by partial urethral ligature. Contraction and relaxation experiments

  9. Consideration of hot channel factors in design for providing operating margins on coolant channel outlet temperature

    International Nuclear Information System (INIS)

    Sharma, V.K.; Surendar, C.; Bapat, C.N.

    1994-01-01

    The Indian Pressurized Heavy Water Reactors (IPHWR) are horizontal pressure tube reactors using natural uranium oxide fuel in the form of short (495 mm) clusters. The fuel clusters in the Zr-Nb pressure tubes are cooled by high pressure, high temperature and subcooled circulating heavy water. Coolant flow distribution to individual channels is designed to match the power distribution so as to obtain uniform coolant outlet temperature. However, during operation, the coolant outlet temperature in individual channels deviate from their nominal value due to: tolerances in process design; effects of grid frequency on the pump speed; deviation in channel powers from the nominal values due to on-power fuelling and movement of reactivity devices, and so on. Thus an operating margin, between the highest permissible and nominal coolant outlet temperatures, is required taking into account various hot channel factors that contribute to higher coolant outlet temperatures. The paper discusses the methodology adopted to assess various hot channel factors which would provide optimum operating margins while ensuring sub-cooling. (author)

  10. Parallel segmented outlet flow high performance liquid chromatography with multiplexed detection

    International Nuclear Information System (INIS)

    Camenzuli, Michelle; Terry, Jessica M.; Shalliker, R. Andrew; Conlan, Xavier A.; Barnett, Neil W.; Francis, Paul S.

    2013-01-01

    Graphical abstract: -- Highlights: •Multiplexed detection for liquid chromatography. •‘Parallel segmented outlet flow’ distributes inner and outer portions of the analyte zone. •Three detectors were used simultaneously for the determination of opiate alkaloids. -- Abstract: We describe a new approach to multiplex detection for HPLC, exploiting parallel segmented outlet flow – a new column technology that provides pressure-regulated control of eluate flow through multiple outlet channels, which minimises the additional dead volume associated with conventional post-column flow splitting. Using three detectors: one UV-absorbance and two chemiluminescence systems (tris(2,2′-bipyridine)ruthenium(III) and permanganate), we examine the relative responses for six opium poppy (Papaver somniferum) alkaloids under conventional and multiplexed conditions, where approximately 30% of the eluate was distributed to each detector and the remaining solution directed to a collection vessel. The parallel segmented outlet flow mode of operation offers advantages in terms of solvent consumption, waste generation, total analysis time and solute band volume when applying multiple detectors to HPLC, but the manner in which each detection system is influenced by changes in solute concentration and solution flow rates must be carefully considered

  11. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; Rauws, Erik A. J.; Fockens, Paul; van Hooft, Jeanin E.

    2015-01-01

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that

  12. Endoscopic magnetic gastroenteric anastomosis for palliation of malignant gastric outlet obstruction: a prospective multicenter study

    NARCIS (Netherlands)

    van Hooft, Jeanin E.; Vleggaar, Frank P.; Moine, Olivier Le; Bizzotto, Alessandra; Voermans, Rogier P.; Costamagna, Guido; Devière, Jacques; Siersema, Peter D.; Fockens, Paul

    2010-01-01

    Background: Palliation of malignant gastric outlet obstruction remains challenging. Although there are 2 established treatment options, ie, surgical gastrojejunostomy and endoscopic duodenal stent insertion, there is an ongoing search for a technique that would combine the safety and rapid effect of

  13. A CLINICAL STUDY ON GASTRIC OUTLET OBSTRUCTION IN A SOUTH INDIAN TEACHING HOSPITAL

    Directory of Open Access Journals (Sweden)

    Sailaja

    2015-10-01

    Full Text Available Gastric outlet obstruction is defined as a clinical and patho - physiological consequence of any disease process that produces a mechanical impediment to gastric emptying which may be extrinsic or intrinsic. Gastric outlet obstruction can be a diagnostic and treatment dilemma. Endoscopy of upper gastrointestinal tract has been a sensitive and specific investigation to study the status of gastric outlet - the pylorus and has enabled early detection of lesions of both stomach a nd duodenum. We undertook a prospective clinical study regarding incidence, etiology, investigation and management of cases of Gastric outlet obstruction in adults in a period of three years. In our study the m ost common cause of GOO is Carcinoma stomach a ntral region 46.6% , duodenal ulcer 33.3% , corrosive acid ingestion sequel 8.3%, peri ampullary carcinoma 6.6%, Ca pancreas 3.3%% , cholangio Carcinoma 1.6%. Males are more commonly involved in a ratio of M: F=3:1. Surgical procedures done varied from defini tive resections to palliative bypass or feeding jejunostomy for enteral feeding

  14. Parallel segmented outlet flow high performance liquid chromatography with multiplexed detection

    Energy Technology Data Exchange (ETDEWEB)

    Camenzuli, Michelle [Australian Centre for Research on Separation Science (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), Sydney, NSW (Australia); Terry, Jessica M. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia); Shalliker, R. Andrew, E-mail: r.shalliker@uws.edu.au [Australian Centre for Research on Separation Science (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), Sydney, NSW (Australia); Conlan, Xavier A.; Barnett, Neil W. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia); Francis, Paul S., E-mail: paul.francis@deakin.edu.au [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia)

    2013-11-25

    Graphical abstract: -- Highlights: •Multiplexed detection for liquid chromatography. •‘Parallel segmented outlet flow’ distributes inner and outer portions of the analyte zone. •Three detectors were used simultaneously for the determination of opiate alkaloids. -- Abstract: We describe a new approach to multiplex detection for HPLC, exploiting parallel segmented outlet flow – a new column technology that provides pressure-regulated control of eluate flow through multiple outlet channels, which minimises the additional dead volume associated with conventional post-column flow splitting. Using three detectors: one UV-absorbance and two chemiluminescence systems (tris(2,2′-bipyridine)ruthenium(III) and permanganate), we examine the relative responses for six opium poppy (Papaver somniferum) alkaloids under conventional and multiplexed conditions, where approximately 30% of the eluate was distributed to each detector and the remaining solution directed to a collection vessel. The parallel segmented outlet flow mode of operation offers advantages in terms of solvent consumption, waste generation, total analysis time and solute band volume when applying multiple detectors to HPLC, but the manner in which each detection system is influenced by changes in solute concentration and solution flow rates must be carefully considered.

  15. 77 FR 74454 - Media Outlets for Publication of Legal and Action Notices in the Southern Region

    Science.gov (United States)

    2012-12-14

    ... Outlets for Publication of Legal and Action Notices in the Southern Region AGENCY: Forest Service, USDA. ACTION: Notice. SUMMARY: Deciding Officers in the Southern Region will publish notice of decisions... newspapers listed in the SUPPLEMENTARY INFORMATION section of this notice. The Southern Region consists of...

  16. Designing vertical shafts for mines with deepening and outlet of rock to the operating level

    Energy Technology Data Exchange (ETDEWEB)

    Durov, Ye.M.

    1983-01-01

    Requirements for designing the cross sections of central shafts are examined, as well as those for determining the productivity of lifts and equipment of the shafts with a condition of use in a subsequent technological layout of their deepening with outlet of the rock to the operating level. Typical cross sections of skip and cellular shafts are given.

  17. Local concentration of fast-food outlets is associated with poor nutrition and obesity.

    Science.gov (United States)

    Kruger, Daniel J; Greenberg, Emily; Murphy, Jillian B; DiFazio, Lindsay A; Youra, Kathryn R

    2014-01-01

    We investigated the relationship of the local availability of fast-food restaurant locations with diet and obesity. We geocoded addresses of survey respondents and fast-food restaurant locations to assess the association between the local concentration of fast-food outlets, BMI, and fruit and vegetable consumption. The survey was conducted in Genesee County, Michigan. There were 1345 individuals included in this analysis, and the response rate was 25%. The Speak to Your Health! Community Survey included fruit and vegetable consumption items from the Behavioral Risk Factor Surveillance System, height, weight, and demographics. We used ArcGIS to map fast-food outlets and survey respondents. Stepwise linear regressions identified unique predictors of body mass index (BMI) and fruit and vegetable consumption. Survey respondents had 8 ± 7 fast-food outlets within 2 miles of their home. Individuals living in close proximity to fast-food restaurants had higher BMIs t(1342) = 3.21, p food availability, which may constrain the success of nutrition promotion efforts. Efforts to decrease the local availability of unhealthy foods as well as programs to help consumers identify strategies for obtaining healthy meals at fast-food outlets may improve health outcomes.

  18. CFD Analysis on a Core Outlet Flow through the Fuel Alignment Plant of SMART

    International Nuclear Information System (INIS)

    Kim, Y. I.; Bae, Y. M.; Kim, K. K.

    2014-01-01

    CFD (Computational Fluid Dynamics) simulations were performed to confirm the core flow distribution for SMART, which acquired standard design approval in 2012. In this paper, CFD simulation is also used to calculate the pressure distribution of a core outlet, a Fuel Alignment Plate (FAP), for SMART. In SMART, the fluid discharged from the Steam Generator comes into a Flow Mixing Header Assembly (FMHA), and is rearranged and split into a very fine size. The FMHA is greatly important for enhancing the flow distribution of a downcomer during a normal operation, transient, and even accidents. Then, the fluid discharged from the FMHA flows into the core upstream through flow skirt holes. The Low Core Support Plate (LCSP) reallocates the flow introducing into the inlet core from the core upstream. The deviation of flow distribution becomes smaller or almost disappears by LCSP holes having relatively large loss coefficient compared to the downstream flow deviation. In an open core, the flow deviation at the core inlet region is diminished by cross flow as it goes upward. Near the core outlet, the flow distribution can be distorted by the influence of a Fuel Alignment Plate (FAP) installed above the fuels. In this paper, the effect of the core outlet flow structure such as the FAP holes of SMART is investigated. Before the calculation, the influences of mesh size and turbulence models are inspected. CFD simulations were performed to investigate the effect of FAP flow holes on the core outlet flow of SMART. As a preliminary study, the dependency of the mesh size and turbulence models was tested; a fine grid was applied, the effect of which is negligible, and the core outlet flow is not sensitive to the turbulence models. In brief, the flow resistance of FAP is less than 15% of that of the fuel assemblies. The flow resistance deviation between two flow path patterns is less than 1% of that of active core. Even two flow path patterns located at the downstream location of the

  19. Change in alcohol outlet density and alcohol-related harm to population health (CHALICE

    Directory of Open Access Journals (Sweden)

    Fone David

    2012-06-01

    Full Text Available Abstract Background Excess alcohol consumption has serious adverse effects on health and violence-related harm. In the UK around 37% of men and 29% of women drink to excess and 20% and 13% report binge drinking. The potential impact on population health from a reduction in consumption is considerable. One proposed method to reduce consumption is to reduce availability through controls on alcohol outlet density. In this study we investigate the impact of a change in the density of alcohol outlets on alcohol consumption and alcohol-related harms to health in the community. Methods/Design A natural experiment of the effect of change in outlet density between 2005–09, in Wales, UK; population 2.4 million aged 16 years and over. Data on outlets are held by the 22 local authorities in Wales under The Licensing Act 2003. The study outcomes are change in (1 alcohol consumption using data from annual Welsh Health Surveys, (2 alcohol-related hospital admissions using the Patient Episode Database for Wales, (3 Accident & Emergency department attendances between midnight–6am, and (4 alcohol-related violent crime against the person, using Police data. The data will be anonymously record-linked within the Secure Anonymised Information Linkage Databank at individual and 2001 Census Lower Super Output Area levels. New methods of network analysis will be used to estimate outlet density. Longitudinal statistical analysis will use (1 multilevel ordinal models of consumption and logistic models of admissions and Accident & Emergency attendance as a function of change in individual outlet exposure, adjusting for confounding variables, and (2 spatial models of the change in counts/rates of each outcome measure and outlet density. We will assess the impact on health inequalities and will correct for population migration. Discussion This inter-disciplinary study requires expertise in epidemiology and public health, health informatics, medical statistics

  20. Access to food retail outlets in County Durham, UK: a pragmatic cross-sectional study.

    Science.gov (United States)

    Mills, Susanna; Wright, Tim

    2015-02-26

    Strong links exist between deprivation, obesity, and dietary quality. Increasing interest has focussed on the concept of access to food and so-called food deserts, defined by a policy working group of the UK Low Income Project Team in 1995 as "areas of relative exclusion where people experience physical and economic barriers to accessing healthy food". We aimed to establish the accessibility of food retail outlets in County Durham, a county in north-east England, UK, considering physical access, affordability, and food range and quality. In a pragmatic cross-sectional study in County Durham, we used information from town surveys and food business databases to locate and identify food retail outlets. The prevalence of deprivation, obesity, retail outlets, takeaway outlets, and ratio of retail to takeaway outlets was mapped, to establish local food access, and any associations with deprivation and obesity. The times taken to travel from residences to supermarkets using private car and public transport were also measured. 400 members of the community participated in eight focus groups and commissioned on-street surveys. Focus group transcripts were reviewed alongside the on-street survey responses to identify key issues. Most residents shopped at least weekly for food (n=368, 92%), used a supermarket for their main food shop (372, 93%), travelled for up to 15 min (340, 85%), and used a car for transport (188, 47%). Many survey respondents indicated high levels of satisfaction with food retail outlets (average rating 8·7 out of 10 for agreement with the statement "Overall I am satisfied with the shop where I do my main food shopping"), although financial constraints and transport inconvenience were identified as barriers. Difficulties with food shopping were more widely described in focus groups, and many individuals felt that local shopping provision had declined, with an emergent excess of takeaway outlets. Food retail access was reduced for the disabled, full

  1. Influence of steam leakage through vane, gland, and shaft seals on rotordynamics of high-pressure rotor of a 1,000 MW ultra-supercritical steam turbine

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, P.N. [Shanghai Jiao Tong University, Key Laboratory of Power Machinery and Engineering, Ministry of Education, School of Mechanical Engineering, Shanghai (China); Shanghai Turbine Company, Department of R and D, Shanghai (China); Wang, W.Z.; Liu, Y.Z. [Shanghai Jiao Tong University, Key Laboratory of Power Machinery and Engineering, Ministry of Education, School of Mechanical Engineering, Shanghai (China); Meng, G. [Shanghai Jiao Tong University, State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai (China)

    2012-02-15

    A comparative analysis of the influence of steam leakage through vane, gland, and shaft seals on the rotordynamics of the high-pressure rotor of a 1,000 MW ultra-supercritical steam turbine was performed using numerical calculations. The rotordynamic coefficients associated with steam leakage through the three labyrinth seals were calculated using the control-volume method and perturbation analysis. A stability analysis of the rotor system subject to the steam forcing induced by the leakage flow was performed using the finite element method. An analysis of the influence of the labyrinth seal forcing on the rotordynamics was carried out by varying the geometrical parameters pertaining to the tooth number, seal clearance, and inner diameter of the labyrinth seals, along with the thermal parameters with respect to pressures and temperatures. The results demonstrated that the steam forcing with an increase in the length of the blade for the vane seal significantly influences the rotordynamic coefficients. Furthermore, the contribution of steam forcing to the instability of the rotor is decreased and increased with increases in the seal clearance and tooth number, respectively. The comparison of the rotordynamic coefficients associated with steam leakage through the vane seal, gland seal, and shaft seal convincingly disclosed that, although the steam forcing attenuates the stability of the rotor system, the steam turbine is still operating under safe conditions. (orig.)

  2. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  3. Flow visualization study of two phase flow in a single bend outlet feeder pipe and horizontal annulus of outlet end-fitting of a CANDU reactor

    International Nuclear Information System (INIS)

    Supa-Amornkul, S.; Lister, D.H.; Steward, F.R.

    2005-01-01

    'Full text:' In CANDU-6 reactors, the pressurized high-temperature coolant flows through 380 fuel channels passing horizontally through the core. Each end of a fuel channel has a stainless steel annular end-fitting connected to a carbon steel feeder pipe. The outlet coolant, which is at 310 o C with up to 0.30 steam voidage, turns through 90 o as it passes from flow in the annular end-fitting to pipe flow in the feeder via a Grayloc connector. Since 1996, several CANDU stations have reported excessive corrosion of their outlet feeder pipes; especially between the first metre, which consisted of single or double bends. Early studies related the attack to the hydrodynamics of the coolant and verified that it was a type of flow accelerated corrosion. In order to understand the hydrodynamics of the coolant in the outlet feeders by flow-visualization, a full-scale transparent test section simulating the geometry and orientation of an outlet feeder bend with its upstream annular end-fitting were fabricated. The feeder consisted of a 54 mm inside diameter acrylic pipe with a 73 o bend, connecting to an acrylic simulation of a Grayloc flanged fitting and annular end-fitting. The annular end-fitting consisted of an inner pipe, 110 mm outer diameter, and an outer pipe, 150 mm inner diameter, both 190.7 cm long in length. The tests were performed with water and air at atmospheric pressure and room temperature. The maximum water volumetric flow rate was 19 L/s and the volume fraction of air varied from 0.05 to 0.56. The phase distributions within the feeder pipe and along the length of the annulus were investigated with a digital video recorder. Size, concentration and velocity of the air bubbles at particular locations were studied with a high-speed digital still camera and a high-speed digital video camera. Phase distributions and variations in bubble size with velocity were determined. Particular attention was paid to the flow pattern at the inside of the bend, where a CFD

  4. Flow visualization study of two phase flow in a single bend outlet feeder pipe and horizontal annulus of outlet end-fitting of a CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    Supa-Amornkul, S.; Lister, D.H.; Steward, F.R. [Univ. of New Brunswick, Fredericton, New Brunswick (Canada)]. E-mail: h796e@unb.ca; dlister@unb.ca; fsteward@unb.ca

    2005-07-01

    'Full text:' In CANDU-6 reactors, the pressurized high-temperature coolant flows through 380 fuel channels passing horizontally through the core. Each end of a fuel channel has a stainless steel annular end-fitting connected to a carbon steel feeder pipe. The outlet coolant, which is at 310{sup o}C with up to 0.30 steam voidage, turns through 90{sup o} as it passes from flow in the annular end-fitting to pipe flow in the feeder via a Grayloc connector. Since 1996, several CANDU stations have reported excessive corrosion of their outlet feeder pipes; especially between the first metre, which consisted of single or double bends. Early studies related the attack to the hydrodynamics of the coolant and verified that it was a type of flow accelerated corrosion. In order to understand the hydrodynamics of the coolant in the outlet feeders by flow-visualization, a full-scale transparent test section simulating the geometry and orientation of an outlet feeder bend with its upstream annular end-fitting were fabricated. The feeder consisted of a 54 mm inside diameter acrylic pipe with a 73{sup o} bend, connecting to an acrylic simulation of a Grayloc flanged fitting and annular end-fitting. The annular end-fitting consisted of an inner pipe, 110 mm outer diameter, and an outer pipe, 150 mm inner diameter, both 190.7 cm long in length. The tests were performed with water and air at atmospheric pressure and room temperature. The maximum water volumetric flow rate was 19 L/s and the volume fraction of air varied from 0.05 to 0.56. The phase distributions within the feeder pipe and along the length of the annulus were investigated with a digital video recorder. Size, concentration and velocity of the air bubbles at particular locations were studied with a high-speed digital still camera and a high-speed digital video camera. Phase distributions and variations in bubble size with velocity were determined. Particular attention was paid to the flow pattern at the inside

  5. Preparation, melting behavior and thermal stability of poly(lactic acid)/poly(propylene carbonate) blends processed by vane extruder

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Wei, E-mail: zw55624@163.com; Chen, Rongyuan; Zhang, Haichen; Qu, Jinping, E-mail: jpqu@scut.edu.cn [National Engineering Research Center of Novel Equipment for Polymer Processing, South China University of Technology, Guangzhou 510640 (China)

    2016-03-09

    Poly (lactic acid) (PLA)/Poly (propylene carbonate) (PPC) blends were prepared by vane extruder which is a type of novel polymer processing extruder based on elongation force field. Scanning electron microscope (SEM), differential scanning calorimetry (DSC) and thermogravimetric (TG) were used respectively to analyze the compatibility, the melting behavior and thermal stability properties of PLA/PPC blends affected by the different content of PPC. The results showed that with the increase of the PPC content, the glass transition temperature of PLA was reduced, and the glass transition temperature of PPC was increased, which indicated that PLA and PPC had partial compatibility. The cold crystallization temperature of PLA increased with the increase of the PPC content, which showed that PPC hindered the cold crystallization process of PLA. The addition of PPC had little impact on the melting process of PLA, and the melting temperature of PLA was almost kept the same value. Thermogravimetric analysis showed that the thermal stability of PPC was worse than that of PLA, the addition of PPC reduced the thermal stability of PLA.

  6. Simulation of performance of centrifugal circulators with vane-less diffuser for GCR applications - HTR2008-58166

    International Nuclear Information System (INIS)

    Tauveron, N.

    2008-01-01

    In the frame of the international forum Gen lV, CEA has selected various innovative concepts of Gas cooled Nuclear Reactor. Among them, an indirect-cycle gas reactor is under consideration. Thermal hydraulic performances are a key issue for the design. For transient conditions and decay heat removal situations, the thermal hydraulic performance must remain as high as possible. In this context, all the transient situations, the incidental and accidental scenarios must be evaluated by a validated sys-tem code able to correctly describe, in particular, the thermal-hydraulics of the whole plant. As concepts use a helium compressor to maintain the flow in the core, a special emphasis must be laid on compressor modelling. Centrifugal circulators with a vane-less diffuser have significant properties in term of simplicity, cost, ability to operate over a wide range of conditions. The objective of this paper is to present a dedicated description of centrifugal compressor, based on a one dimensional approach. This type of model requires various correlations as input data. The present contribution consists in establishing and validating the numerical simulations (including different sets of correlations) by comparison with representative experimental data. The results obtained show a qualitatively correct behaviour of the model compared to open literature cases of the gas turbine aircraft community and helium circulators of High Temperature Gas Reactors. Further work on modelling and validation are nevertheless needed to have a better confidence in the simulation predictions. (authors)

  7. Zero-gravity Mean Free Surface Curvature of a Confined Liquid in a Radially-Vaned Container

    Science.gov (United States)

    Chen, Yongkang; Callahan, Michael; Weislogel, Mark

    2013-01-01

    A variety of increasingly intricate container geometries are under consideration for the passive manipulation of liquids aboard spacecraft where the impact of gravity may be neglected. In this study we examine the mean curvature of a liquid volume confined within a radial array of disconnected vanes of infinite extent. This particular geometry possesses a number of desirable characteristics relevant to waste water treatment aboard spacecraft for life support. It is observed that under certain conditions the slender shape of the free surface approaches an asymptote, which can be predicted analytically using new hybrid boundary conditions proposed herein. This contribution represents possibly the final extension of what has been referred to as the method of de Lazzer et al. (1996). The method enables the integration of the Young-Laplace equation over a domain with its boundaries, including the wetted portion of the solid boundaries, symmetry planes, and circular arcs representing free surfaces at the center plane of the liquid body. Asymptotic solutions at several limits are obtained and the analysis is confirmed with numerical computations.

  8. Effects of grid spacer with mixing vane on entrainments and depositions in two-phase annular flows

    Directory of Open Access Journals (Sweden)

    Akimaro Kawahara

    2015-06-01

    Full Text Available The effects of mixing vanes (MVs attached to a grid spacer on the characteristics of air–water annular flows were experimentally investigated. To know the effects, a grid spacer with or without MV was inserted in a vertical circular pipe of 16-mm internal diameter. For three cases (i.e., no spacer, spacer without MV, and spacer with MV, the liquid film thickness, liquid entrainment fraction, and deposition rate were measured by the constant current method, single liquid film extraction method, and double liquid film extraction method, respectively. The MVs significantly promote the re-deposition of liquid droplets in the gas core flow into the liquid film on the channel walls. The deposition mass transfer coefficient is three times higher for the spacer with MV than for the spacer without MV, even for cases 0.3-m downstream from the spacer. The liquid film thickness becomes thicker upstream and downstream for the spacer with MV, compared with the thickness for the spacer without MV and for the case with no spacer.

  9. A temporal analysis of the spatial clustering of food outlets around schools in Christchurch, New Zealand, 1966 to 2006.

    Science.gov (United States)

    Day, Peter L; Pearce, Jamie R; Pearson, Amber L

    2015-01-01

    To explore changes in urban food environments near schools, as potential contributors to the rising prevalence of overweight and obesity among children. Addresses of food premises and schools in 1966, 1976, 1986, 1996 and 2006 were geo-coded. For each year, the number and proportion of outlets by category (supermarket/grocery; convenience; fast-food outlet) within 800 m of schools were calculated. The degree of spatial clustering of outlets was assessed using a bivariate K-function analysis. Food outlet categories, school level and school social deprivation quintiles were compared. Christchurch, New Zealand. All schools and food outlets at 10-year snapshots from 1966 to 2006. Between 1966 and 2006, the median number of supermarkets/grocery stores within 800 m of schools decreased from 5 to 1, convenience stores decreased from 2 to 1, and fast-food outlets increased from 1 to 4. The ratio of fast-food outlets to total outlets increased from 0·10 to 0·67. The clustering of fast-food outlets was greatest within 800 m of schools and around the most socially deprived schools. Over the 40-year study period, school food environments in Christchurch can be characterized by increased densities of fast-food outlets within walking distance of schools, especially around the most deprived schools. Since the 1960s, there have been substantial changes to the food environments around schools which may increasingly facilitate away-from-home food consumption for children and provide easily accessible, cheap energy-dense foods, a recognized contributor to the rise in prevalence of overweight and obesity among young people.

  10. From Medical to Recreational Marijuana Sales: Marijuana Outlets and Crime in an Era of Changing Marijuana Legislation.

    Science.gov (United States)

    Freisthler, Bridget; Gaidus, Andrew; Tam, Christina; Ponicki, William R; Gruenewald, Paul J

    2017-06-01

    A movement from medical to recreational marijuana use allows for a larger base of potential users who have easier access to marijuana, because they do not have to visit a physician before using marijuana. This study examines whether changes in the density of marijuana outlets were related to violent, property, and marijuana-specific crimes in Denver, CO during a time in which marijuana outlets began selling marijuana for recreational, and not just medical, use. We collected data on locations of crimes, marijuana outlets and covariates for 481 Census block groups over 34 months (N = 16,354 space-time units). A Bayesian Poisson space-time model assessed statistical relationships between independent measures and crime counts within "local" Census block groups. We examined spatial "lag" effects to assess whether crimes in Census block groups adjacent to locations of outlets were also affected. Independent of the effects of covariates, densities of marijuana outlets were unrelated to property and violent crimes in local areas. However, the density of marijuana outlets in spatially adjacent areas was positively related to property crime in spatially adjacent areas over time. Further, the density of marijuana outlets in local and spatially adjacent blocks groups was related to higher rates of marijuana-specific crime. This study suggests that the effects of the availability of marijuana outlets on crime do not necessarily occur within the specific areas within which these outlets are located, but may occur in adjacent areas. Thus studies assessing the effects of these outlets in local areas alone may risk underestimating their true effects.

  11. The impact of interventions to promote healthier ready‐to‐eat meals (to eat in, to take away or to be delivered) sold by specific food outlets open to the general public: a systematic review

    Science.gov (United States)

    Summerbell, C. D.; Moore, H. J.; Routen, A.; Lake, A. A.; Adams, J.; White, M.; Araujo‐Soares, V.; Abraham, C.; Adamson, A. J.; Brown, T. J.

    2016-01-01

    Summary Introduction Ready‐to‐eat meals sold by food outlets that are accessible to the general public are an important target for public health intervention. We conducted a systematic review to assess the impact of such interventions. Methods Studies of any design and duration that included any consumer‐level or food‐outlet‐level before‐and‐after data were included. Results Thirty studies describing 34 interventions were categorized by type and coded against the Nuffield intervention ladder: restrict choice = trans fat law (n = 1), changing pre‐packed children's meal content (n = 1) and food outlet award schemes (n = 2); guide choice = price increases for unhealthier choices (n = 1), incentive (contingent reward) (n = 1) and price decreases for healthier choices (n = 2); enable choice = signposting (highlighting healthier/unhealthier options) (n = 10) and telemarketing (offering support for the provision of healthier options to businesses via telephone) (n = 2); and provide information = calorie labelling law (n = 12), voluntary nutrient labelling (n = 1) and personalized receipts (n = 1). Most interventions were aimed at adults in US fast food chains and assessed customer‐level outcomes. More ‘intrusive’ interventions that restricted or guided choice generally showed a positive impact on food‐outlet‐level and customer‐level outcomes. However, interventions that simply provided information or enabled choice had a negligible impact. Conclusion Interventions to promote healthier ready‐to‐eat meals sold by food outlets should restrict choice or guide choice through incentives/disincentives. Public health policies and practice that simply involve providing information are unlikely to be effective. PMID:27899007

  12. Broadband Fan Noise Prediction System for Turbofan Engines. Volume 1; Setup_BFaNS User's Manual and Developer's Guide

    Science.gov (United States)

    Morin, Bruce L.

    2010-01-01

    Pratt & Whitney has developed a Broadband Fan Noise Prediction System (BFaNS) for turbofan engines. This system computes the noise generated by turbulence impinging on the leading edges of the fan and fan exit guide vane, and noise generated by boundary-layer turbulence passing over the fan trailing edge. BFaNS has been validated on three fan rigs that were tested during the NASA Advanced Subsonic Technology Program (AST). The predicted noise spectra agreed well with measured data. The predicted effects of fan speed, vane count, and vane sweep also agreed well with measurements. The noise prediction system consists of two computer programs: Setup_BFaNS and BFaNS. Setup_BFaNS converts user-specified geometry and flow-field information into a BFaNS input file. From this input file, BFaNS computes the inlet and aft broadband sound power spectra generated by the fan and FEGV. The output file from BFaNS contains the inlet, aft and total sound power spectra from each noise source. This report is the first volume of a three-volume set documenting the Broadband Fan Noise Prediction System: Volume 1: Setup_BFaNS User s Manual and Developer s Guide; Volume 2: BFaNS User's Manual and Developer s Guide; and Volume 3: Validation and Test Cases. The present volume begins with an overview of the Broadband Fan Noise Prediction System, followed by step-by-step instructions for installing and running Setup_BFaNS. It concludes with technical documentation of the Setup_BFaNS computer program.

  13. Broadband Fan Noise Prediction System for Turbofan Engines. Volume 2; BFaNS User's Manual and Developer's Guide

    Science.gov (United States)

    Morin, Bruce L.

    2010-01-01

    Pratt & Whitney has developed a Broadband Fan Noise Prediction System (BFaNS) for turbofan engines. This system computes the noise generated by turbulence impinging on the leading edges of the fan and fan exit guide vane, and noise generated by boundary-layer turbulence passing over the fan trailing edge. BFaNS has been validated on three fan rigs that were tested during the NASA Advanced Subsonic Technology Program (AST). The predicted noise spectra agreed well with measured data. The predicted effects of fan speed, vane count, and vane sweep also agreed well with measurements. The noise prediction system consists of two computer programs: Setup_BFaNS and BFaNS. Setup_BFaNS converts user-specified geometry and flow-field information into a BFaNS input file. From this input file, BFaNS computes the inlet and aft broadband sound power spectra generated by the fan and FEGV. The output file from BFaNS contains the inlet, aft and total sound power spectra from each noise source. This report is the second volume of a three-volume set documenting the Broadband Fan Noise Prediction System: Volume 1: Setup_BFaNS User s Manual and Developer s Guide; Volume 2: BFaNS User s Manual and Developer s Guide; and Volume 3: Validation and Test Cases. The present volume begins with an overview of the Broadband Fan Noise Prediction System, followed by step-by-step instructions for installing and running BFaNS. It concludes with technical documentation of the BFaNS computer program.

  14. Homebuyer's Guide.

    Science.gov (United States)

    Sindt, Roger P.; Harris, Jack

    Designed to assist prospective buyers in making such important decisions as whether to buy a new or older home and within what price range, the guide provides information on the purchase process. Discussion of the purchase process covers the life-cycle costs (recurring homeownership costs that must be met every month); selection of a home;…

  15. CFD Study of Industrial FCC Risers: The Effect of Outlet Configurations on Hydrodynamics and Reactions

    Directory of Open Access Journals (Sweden)

    Gabriela C. Lopes

    2012-01-01

    Full Text Available Fluid catalytic cracking (FCC riser reactors have complex hydrodynamics, which depend not only on operating conditions, feedstock quality, and catalyst particles characteristics, but also on the geometric configurations of the reactor. This paper presents a numerical study of the influence of different riser outlet designs on the dynamic of the flow and reactor efficiency. A three-dimensional, three-phase flow model and a four-lump kinetic scheme were used to predict the performance of the reactor. The phenomenon of vaporization of the liquid oil droplets was also analyzed. Results showed that small changes in the outlet configuration had a significant effect on the flow patterns and consequently, on the reaction yields.

  16. Numerical Simulation of Two-branch Hot Gas Mixing at Reactor Outlet of HTR-PM

    International Nuclear Information System (INIS)

    Hao Pengefei; Zhou Yangping; Li Fu; Shi Lei; He Heng

    2014-01-01

    A series of two-branch model experiment has been finished to investigate the thermal mixing efficiency of the HTR-PM reactor outlet. This paper introduces the numerical simulation on the design of thermal mixing structure of HTR-PM and the test facility with Fluent software. The profiles of temperature, pressure and velocity in the mixing structure design and the test facility are discussed by comparing with the model experiment results. The numerical simulation results of the test facility have good agreement to the experiment results. In addition, the thermal-fluid characters obtained by numerical simulation show the thermal mixing structure of HTR-PM has similarity with the test facility. Finally, it is concluded that the thermal mixing design at HTR-PM reactor outlet can fulfilled the requirements for high thermal mixing efficiency and appropriate pressure drop. (author)

  17. Radiological findings of gastric adenomyoma in a neonate presenting with gastric outlet obstruction.

    Science.gov (United States)

    Rhim, Jung Hyo; Kim, Woo Sun; Choi, Young Hun; Cheon, Jung-Eun; Park, Sung Hye

    2013-03-01

    Gastric adenomyoma is a rare tumour-like lesion composed of glandular components and smooth muscle bundles. We report a case of gastric adenomyoma in a 1-week-old neonate who presented with gastric outlet obstruction. To the best of our knowledge, this is the youngest child reported with gastric adenomyoma and a unique case demonstrating radiological findings of gastric adenomyoma in a young infant. At US, the lesion was seen as an asymmetrical mass-like wall-thickening of the pylorus. Upper gastrointestinal series showed findings similar to those seen in a case of hypertrophic pyloric stenosis. We suggest that gastric adenomyoma should be included in the causes of gastric outlet obstruction in neonates even though it is rare in young children.

  18. Experiment study on thermal mixing performance of HTR-PM reactor outlet

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yangping, E-mail: zhouyp@mail.tsinghua.edu.cn [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, the Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084 (China); Hao, Pengfei [School of Aerospace, Tsinghua University, Beijing 100084 (China); Li, Fu; Shi, Lei [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, the Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084 (China); He, Feng [School of Aerospace, Tsinghua University, Beijing 100084 (China); Dong, Yujie; Zhang, Zuoyi [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, the Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084 (China)

    2016-09-15

    A model experiment is proposed to investigate the thermal mixing performance of HTR-PM reactor outlet. The design of the test facility is introduced, which is set at a scale of 1:2.5 comparing with the design of thermal mixing structure at HTR-PM reactor outlet. The test facility using air as its flow media includes inlet pipe system, electric heaters, main mixing structure, hot gas duct, exhaust pipe system and I&C system. Experiments are conducted on the test facility and the values of thermal-fluid parameters are collected and analyzed, which include the temperature, pressure and velocity of the flow as well as the temperature of the tube wall. The analysis results show the mixing efficiency of the test facility is higher than that required by the steam generator of HTR-PM, which indicates that the thermal mixing structure of HTR-PM fulfills its design requirement.

  19. Influence of the outlet air temperature on the thermohydraulic behaviour of air coolers

    Directory of Open Access Journals (Sweden)

    Đorđević Emila M.

    2003-01-01

    Full Text Available The determination of the optimal process conditions for the operation of air coolers demands a detailed analysis of their thermohydraulic behaviour on the one hand, and the estimation of the operating costs, on the other. One of the main parameters of the thermohydraulic behaviour of this type of equipment, is the outlet air temperature. The influence of the outlet air temperature on the performance of air coolers (heat transfer coefficient overall heat transfer coefficient, required surface area for heat transfer air-side pressure drop, fan power consumption and sound pressure level was investigated in this study. All the computations, using AirCooler software [1], were applied to cooling of the process fluid and the condensation of a multicomponent vapour mixture on two industrial devices of known geometries.

  20. Fruit and Vegetable Intake in Adolescents: Association with Socioeconomic Status and Exposure to Supermarkets and Fast Food Outlets

    Directory of Open Access Journals (Sweden)

    Chalida M. Svastisalee

    2012-01-01

    Full Text Available Background. We investigated differences in family social class associations between food outlet exposure and fruit and vegetable intake. Methods. We supplemented data from the 2006 Health Behavior in School Aged Children Study (n=6,096 with geocoded food outlet information surrounding schools (n=80. We used multilevel logistic regression to examine associations between infrequent fruit and vegetable intake and supermarket and fast food outlet concentration, stratified by family social class. Results. Boys and older children were most likely to eat fruit and vegetables infrequently. High fast food outlet exposure was marginally significant for low fruit intake in low social class children only. Children from middle and low social class backgrounds attending schools with combined high fast food outlet/low supermarket exposure were most likely to report infrequent fruit intake (ORlow=1.60; CI:  1.02–2.45; ORmid=1.40; CI:  1.03–190. Children from low social class backgrounds were also likely to report infrequent vegetable intake, given low supermarket and high fast food outlet exposure (OR=1.79; CI:  0.99–3.21. Conclusion. Our findings suggest social class modifies the relationship between intake and food outlet concentration. School interventions improving fruit and vegetable intake should consider neighborhood surroundings, targetting older children from low social class backgrounds.

  1. Cosmogenic nuclides constrain surface fluctuations of an East Antarctic outlet glacier since the Pliocene.

    OpenAIRE

    Jones, R.S.; Norton, K.P.; Mackintosh, A.N.; Anderson, J.T.H.; Kubik, P.; Vockenhuber, C.; Wittman, H.; Fink, D.; Wilson, G.S.; Golledge, N.R.; McKay, R.

    2017-01-01

    Understanding past changes in the Antarctic ice sheets provides insight into how they might respond to future climate warming. During the Pliocene and Pleistocene, geological data show that the East Antarctic Ice Sheet responded to glacial and interglacial cycles by remaining relatively stable in its interior, but oscillating at its marine-based margin. It is currently not clear how outlet glaciers, which connect the ice sheet interior to its margin, responded to these orbitally-paced climate...

  2. Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Hideo; Sakoda, Naoya; Hattori, Shigeru; Kawabata, Takuya; Saiki, Munehiro; Fujita, Yasufumi; Yunoki, Keiji; Hisamochi, Kunikazu; Mine, Yoshinari

    2017-06-01

    Prosthetic valve fracture is a serious complication and may arise in patient post-valve replacement. We experienced an outlet strut fracture and leaflet escape of a Bjork-Shiley convexo-concave valve. We performed an emergency redo mitral valve replacement and successfully retrieved the fractured strut and escaped leaflet from superficial femoral artery and the abdominal aorta. The patient showed an uneventful postoperative recovery.

  3. Are Customers Satisfied With Healthier Food Options At South African Fast-Food Outlets?

    OpenAIRE

    Michael C. Cant; Ricardo Machado; Melanie Gopaul

    2014-01-01

    Fast-food consumption has been a staple for many people; however, due to rising health concerns, there has been an increasing interest in the consumption of healthier food both in South Africa and elsewhere. Many consumers are demanding better quality foods that offer nutritional benefits. This global trend has led to fast-food outlets adding healthier food options to their menus. Limited literature exists on customer satisfaction with regards to the food quality of these healthier food optio...

  4. Marketing Communications Research On Food & Beverage Outlets Of Moevenpick Hotel Saigon

    OpenAIRE

    Hoang Minh, Tam

    2012-01-01

    The purpose of this thesis was to conduct a marketing communications research on Food & Beverage Outlets of Moevenpick hotel Saigon. Besides, a short description of consumer rating on F&B service quality was other mission specifically assigned by the commissioned party. The research provided general information about both targeted potential customers from surrounding areas and current hotel guest and restaurant diner. Next was the analysis derived from the customer survey’s result, the ran...

  5. Global consolidation of industries and business failures: insights from brick-and-mortar and online outlets

    OpenAIRE

    Amankwah-Amoah, Joseph

    2017-01-01

    Although online platforms are increasingly seen as a linchpin for firms competing in the 21st century, our understanding of competition between the traditional brick-and-mortar and online outlets, and how this can lead to different types of business failures, remains limited. In the light of the disjointed nature of the current streams of research, we propose an integrated framework that classifies the differential effects of online and brick-and-mortar competition. Based on a review of the l...

  6. A Comparative Analysis of the Distributions of KFC and McDonald’s Outlets in China

    OpenAIRE

    Yikang Rui; Huang Huang; Min Lu; Bao Wang; Jiechen Wang

    2016-01-01

    Mainland China has become one of the most important markets for international fast-food chains over the past decade. To study the regional spread of KFC and McDonald’s outlets in Chinese cities, the correlation of their distributions and degree of market expansion were explored and compared to analyze both the local and the global spatial autocorrelations. A geographically weighted Poisson regression model was also used to examine the influence of demographic, economic, and geographic factors...

  7. Simulation of inlet and outlet riser break sequences in the N Reactor

    International Nuclear Information System (INIS)

    Bolander, M.A.; Fletcher, C.D.

    1988-02-01

    This report documents work performed at the Idaho National Engineering Laboratory (INEL) in support of the Westinghouse Hanford Company safety analyses of the N Reactor. The RELAP5/MOD2 computer code was used in analyzing two hypothetical transients. The computer code was modified specifically to simulate the refill behavior in the N Reactor process tubes. The transients analyzed were a double-ended rupture of an inlet riser column and a double-ended rupture of an outlet riser column

  8. Rapid Holocene thinning of outlet glaciers followed by readvance in the western Ross Embayment, Antarctica

    Science.gov (United States)

    Jones, R. S.; Whitmore, R.; Mackintosh, A.; Norton, K. P.; Eaves, S.; Stutz, J.

    2017-12-01

    Investigating Antarctic deglaciation following the LGM provides an opportunity to better understand patterns, mechanisms and drivers of ice sheet retreat. In the Ross Sea sector, geomorphic features preserved on the seafloor indicate that streaming East Antarctic outlet glaciers once extended >100 km offshore of South Victoria Land prior to back-stepping towards their modern configurations. In order to adequately interpret the style and causes of this retreat, the timing and magnitude of corresponding ice thickness change is required. We present new constraints on ice surface lowering from Mawson Glacier, an outlet of the East Antarctic Ice Sheet that flows into the western Ross Sea. Surface-exposure (10Be) ages from samples collected in elevation transects above the modern ice surface reveal that rapid thinning occurred at 5-8 ka, broadly coeval with new ages of grounding-line retreat at 6 ka and rapid thinning recorded at nearby Mackay Glacier at 7 ka. Our data also show that a moraine formed near to the modern ice margin of Mawson Glacier at 0.8 ka, which, together with historical observations, indicates that glaciers in this region readvanced during the last thousand years. We argue that 1) the accelerated thinning of outlet glaciers was driven by local grounding-line retreat through overdeepened basins during the early-mid Holocene, and 2) the glaciers subsequently readvanced, possibly linked to late Holocene sea-ice expansion, before retreating to their current positions. Our work demonstrates that these outlet glaciers were closely coupled to environmental and topography-induced perturbations near their termini throughout the Holocene.

  9. Mean energy of ions at outlet of a type Ecr plasma source

    International Nuclear Information System (INIS)

    Gutierrez T, C.; Gonzalez D, J.

    1998-01-01

    In this work it is described the calculations to mean energy of the ions in the extraction zone of a type Ecr plasma source considering the presence of a metallic substrate. This zone is characterized by the existence of a divergent magnetic field. It is showed that mean energy is function as the distance between the outlet and substrate as the value of the external magnetic field. (Author)

  10. Climatology, hydrology, and simulation of an emergency outlet, Devils Lake basin, North Dakota

    Science.gov (United States)

    Wiche, Gregg J.; Vecchia, A.V.; Osborne, Leon; Wood, Carrie M.; Fay, James T.

    2000-01-01

    Devils Lake is a natural lake in northeastern North Dakota that is the terminus of a nearly 4,000-square-mile subbasin in the Red River of the North Basin. The lake has not reached its natural spill elevation to the Sheyenne River (a tributary of the Red River of the North) in recorded history. However, geologic evidence indicates a spill occurred sometime within the last 1,800 years. From 1993 to 1999, Devils Lake rose 24.5 feet and, at the present (August 2000), is about 13 feet below the natural spill elevation. The recent lake-level rise has caused flood damages exceeding $300 million and triggered development of future flood-control options to prevent further infrastructure damage and reduce the risk of a potentially catastrophic uncontrolled spill. Construction of an emergency outlet from the west end of Devils Lake to the Sheyenne River is one flood-control option being considered. This report describes the climatologic and hydrologic causes of the recent lake level rise, provides information on the potential for continued lake-level rises during the next 15 years, and describes the potential effectiveness of an emergency outlet in reducing future lake levels and in reducing the risk of an uncontrolled spill. The potential effects of an outlet on downstream water quantity and quality in the upper Sheyenne River also are described.

  11. Transvaginal Mesh and Transanal Resection to Treat Outlet Obstruction Constipation Caused by Rectocele.

    Science.gov (United States)

    Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei

    2017-02-01

    BACKGROUND The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. MATERIAL AND METHODS Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate, and operative time were compared between the 2 groups. RESULTS Total effective rate was 100% in both groups. No long-term chronic pain occurred and discomfort rate of tenesmus was higher in the STARR group than in the TVMR group. Postoperative defecography showed that the rectocele depth was significantly reduced, and the prolapse of the rectal mucosa and the lower rectal capacity was also decreased. Four cases had mesh exposure in the TVMR group and 2 cases in the STARR group had anastomotic bleeding after the surgery. CONCLUSIONS For outlet obstruction constipation caused by rectocele, TVMR and STARR both obtained satisfactory results. Although TVMR is complex with longer operative time and hospitalization period, its long-term effect is better than that of STARR.

  12. Transient Air-Water Flow and Air Demand following an Opening Outlet Gate

    Directory of Open Access Journals (Sweden)

    James Yang

    2018-01-01

    Full Text Available In Sweden, the dam-safety guidelines call for an overhaul of many existing bottom outlets. During the opening of an outlet gate, understanding the transient air-water flow is essential for its safe operation, especially under submerged tailwater conditions. Three-dimensional CFD simulations are undertaken to examine air-water flow behaviors at both free and submerged outflows. The gate, hoisted by wire ropes and powered by AC, opens at a constant speed. A mesh is adapted to follow the gate movement. At the free outflow, the CFD simulations and model tests agree well in terms of outlet discharge capacity. Larger air vents lead to more air supply; the increment becomes, however, limited if the vent area is larger than 10 m2. At the submerged outflow, a hydraulic jump builds up in the conduit when the gate reaches approximately 45% of its full opening. The discharge is affected by the tailwater and slightly by the flow with the hydraulic jump. The flow features strong turbulent mixing of air and water, with build-up and break-up of air pockets and collisions of defragmented water bodies. The air demand rate is several times as much as required by steady-state hydraulic jump with free surface.

  13. [Eleven Patients with Gastric Cancer Who Received Chemotherapy after Stent Placement for Gastric Outlet Obstruction].

    Science.gov (United States)

    Endo, Shunji; Nakagawa, Tomo; Konishi, Ken; Ikenaga, Masakazu; Ohta, Katsuya; Nakashima, Shinsuke; Matsumoto, Kenichi; Nishikawa, Kazuhiro; Ohmori, Takeshi; Yamada, Terumasa

    2017-01-01

    Endoscopic placement of self-expandable metallic stents is reportedly effective for gastric outlet obstructions due to advanced gastric cancer, and is less invasive than gastrojejunostomy. For patients who have good performance status, we administer chemotherapy after stent placement, although the safety and feasibility of this chemotherapy have not yet been discussed in full. Between 2011 and 2015, 15 patients at our institution underwent endoscopic gastroduodenal stent placement for gastric outlet obstruction due to gastric cancer. Eleven of these patients were administered chemotherapy after stent placement. In our case series, we did not observe any specific adverse event caused by stent placement plus chemotherapy. Adverse events after chemotherapy included anemia of CTCAE Grade 3 in 7 patients. Stent-in-stent placement was needed in 2 patients. Neither stent migration nor perforation was observed. Therefore, chemotherapy after stent placement for gastric outlet obstruction due to gastric cancer was considered safe and feasible. Stent placement is useful not only as palliative care for patients with terminal-stage disease, but also as one of the multimodal therapeutic strategies for gastric cancer.

  14. Noise and DC balanced outlet temperature signals for monitoring coolant flow in LMFBR fuel elements

    International Nuclear Information System (INIS)

    Edelmann, M.

    1977-01-01

    Local cooling disturbances in LMFBR fuel elements may have serious safety implications for the whole reactor core. They have to be detected reliably in an early stage of their formation therefore. This can be accomplished in principle by individual monitoring of the coolant flow rate or the coolant outlet temperature of the sub-assemblies with high precision. In this paper a method is proposed to increase the sensitivity of outlet temperature signals to cooling disturbances. Using balanced temperature signals provides a means for eliminating the normal variations from the original signals which limit the sensitivity and speed of response to cooling disturbances. It is shown that a balanced signal can be derived easily from the original temperature signal by subtracting an inlet temperature and a neutron detector signal with appropriate time shift. The method was tested with tape-recorded noise signals of the KNK I reactor at Karlsruhe. The experimental results confirm the theoretical predictions. A significant reduction of the uncertainty of measured outlet temperatures was achieved. This enables very sensitive and fast response monitoring of coolant flow. Furthermore, it was found that minimizing the variance of the balanced signal offers the possibility for a rough determination of the heat transfer coefficient of the fuel rods during normal reactor operation at power. (author)

  15. Air demand estimation in bottom outlets with the particle finite element method. Susqueda Dam case study

    Science.gov (United States)

    Salazar, Fernando; San-Mauro, Javier; Celigueta, Miguel Ángel; Oñate, Eugenio

    2017-07-01

    Dam bottom outlets play a vital role in dam operation and safety, as they allow controlling the water surface elevation below the spillway level. For partial openings, water flows under the gate lip at high velocity and drags the air downstream of the gate, which may cause damages due to cavitation and vibration. The convenience of installing air vents in dam bottom outlets is well known by practitioners. The design of this element depends basically on the maximum air flow through the air vent, which in turn is a function of the specific geometry and the boundary conditions. The intrinsic features of this phenomenon makes it hard to analyse either on site or in full scaled experimental facilities. As a consequence, empirical formulas are frequently employed, which offer a conservative estimate of the maximum air flow. In this work, the particle finite element method was used to model the air-water interaction in Susqueda Dam bottom outlet, with different gate openings. Specific enhancements of the formulation were developed to consider air-water interaction. The results were analysed as compared to the conventional design criteria and to information gathered on site during the gate operation tests. This analysis suggests that numerical modelling with the PFEM can be helpful for the design of this kind of hydraulic works.

  16. Interferometric investigation of turbulently fluctuating temperature in an LMFBR outlet plenum geometry

    International Nuclear Information System (INIS)

    Bennett, R.G.; Golay, M.W.

    1975-01-01

    A novel optical technique is described for the measurement of turbulently fluctuating temperature in a transparent fluid flow. The technique employs a Mach-Zehnder interferometer of extremely short field and a simple photoconductive diode detector. The system produces a nearly linear D.C. electrical analog of the turbulent temperature fluctuations in a small, 1 mm 3 volume. The frequency response extends well above 2500 Hz, and can be improved by the choice of a more sophisticated photodetector. The turbulent sodium mixing in the ANL 1 1 / 15 -scale FFTF outlet plenum is investigated with a scale model outlet mixing plenum, using flows of air. The scale design represents a cross section of the ANL outlet plenum, so that the average recirculating flow inside the test cell is two dimensional. The range of the instrument is 120 0 F above the ambient air temperature. The accuracy is generally +-5 0 F, with most of the error due to noise originating from building vibrations and room noise. The power spectral density of the fluctuating temperature has been observed experimentally at six different stations in the flow. A strong 300 Hz component is generated in the inlet region, which decays as the flow progresses along streamlines. The effect of the inlet Reynolds number and the temperature difference between the inlet flows on the power spectral density has also been investigated. Traces of the actual fluctuating temperature are included for the six stations

  17. Application of the PROMETHEE technique to determine depression outlet location and flow direction in DEM

    Science.gov (United States)

    Chou, Tien-Yin; Lin, Wen-Tzu; Lin, Chao-Yuan; Chou, Wen-Chieh; Huang, Pi-Hui

    2004-02-01

    With the fast growing progress of computer technologies, spatial information on watersheds such as flow direction, watershed boundaries and the drainage network can be automatically calculated or extracted from a digital elevation model (DEM). The stubborn problem that depressions exist in DEMs has been frequently encountered while extracting the spatial information of terrain. Several filling-up methods have been proposed for solving depressions. However, their suitability for large-scale flat areas is inadequate. This study proposes a depression watershed method coupled with the Preference Ranking Organization METHod for Enrichment Evaluations (PROMETHEEs) theory to determine the optimal outlet and calculate the flow direction in depressions. Three processing procedures are used to derive the depressionless flow direction: (1) calculating the incipient flow direction; (2) establishing the depression watershed by tracing the upstream drainage area and determining the depression outlet using PROMETHEE theory; (3) calculating the depressionless flow direction. The developed method was used to delineate the Shihmen Reservoir watershed located in Northern Taiwan. The results show that the depression watershed method can effectively solve the shortcomings such as depression outlet differentiating and looped flow direction between depressions. The suitability of the proposed approach was verified.

  18. Procedure for prolapse and hemorrhoids vs traditional surgery for outlet obstructive constipation.

    Science.gov (United States)

    Lu, Ming; Yang, Bo; Liu, Yang; Liu, Qing; Wen, Hao

    2015-07-14

    To compare the clinical efficacies of two surgical procedures for hemorrhoid rectal prolapse with outlet obstruction-induced constipation. One hundred eight inpatients who underwent surgery for outlet obstructive constipation caused by internal rectal prolapse and circumferential hemorrhoids at the First Affiliated Hospital of Xinjiang Medical University from June 2012 to June 2013 were prospectively included in the study. The patients with rectal prolapse hemorrhoids with outlet obstruction-induced constipation were randomly divided into two groups to undergo either a procedure for prolapse and hemorrhoids (PPH) (n = 54) or conventional surgery (n = 54; control group). Short-term (operative time, postoperative hospital stay, postoperative urinary retention, postoperative perianal edema, and postoperative pain) and long-term (postoperative anal stenosis, postoperative sensory anal incontinence, postoperative recurrence, and postoperative difficulty in defecation) clinical effects were compared between the two groups. The short- and long-term efficacies of the two procedures were determined. In terms of short-term clinical effects, operative time and postoperative hospital stay were significantly shorter in the PPH group than in the control group (24.36 ± 5.16 min vs 44.27 ± 6.57 min, 2.1 ± 1.4 d vs 3.6 ± 2.3 d, both P hemorrhoids.

  19. Transvaginal Mesh and Transanal Resection to Treat Outlet Obstruction Constipation Caused by Rectocele

    Science.gov (United States)

    Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei

    2017-01-01

    Background The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. Material/Methods Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate, and operative time were compared between the 2 groups. Results Total effective rate was 100% in both groups. No long-term chronic pain occurred and discomfort rate of tenesmus was higher in the STARR group than in the TVMR group. Postoperative defecography showed that the rectocele depth was significantly reduced, and the prolapse of the rectal mucosa and the lower rectal capacity was also decreased. Four cases had mesh exposure in the TVMR group and 2 cases in the STARR group had anastomotic bleeding after the surgery. Conclusions For outlet obstruction constipation caused by rectocele, TVMR and STARR both obtained satisfactory results. Although TVMR is complex with longer operative time and hospitalization period, its long-term effect is better than that of STARR. PMID:28146137

  20. Numerical Analysis on Effects of Positioning and Height of the Contoured Endwall on the Three-Dimensional Flow in an Annular Turbine Nozzle Guide Vane Cascade

    International Nuclear Information System (INIS)

    Lee, Wu Sang; Kim, Dae Hyun; Min, Jae Hong; Chung Jin Taek

    2007-01-01

    Endwall losses contribute significantly to the overall losses in modern turbomachinery, especially when aerodynamic airfoil load and pressure ratio are increased. Hence, reducing the extend and intensity of the secondary flow structures helps to enhance overall efficiency. From the large range of viable approaches, a promising combination positioning and height of endwall contouring was chosen. The objective of this study is to document the three-dimensional flow in a turbine cascade in terms of streamwise vorticity, total pressure loss distribution and static pressure distribution on the endwall and blade surface and to propose an appropriate positioning and height of the endwall contouring which show best secondary, overall loss reduction among the simulated endwall. The flow through the gas turbine were numerically analyzed using three dimensional Navier-Stroke equations with a commercial CFD code ANSYS CFX-10. The result shows that the overall loss is reduced near the flat endwall rather than contoured endwall, and the case of contoured endwall installed at 30% from leading edge with height of 25% for span showed best performance

  1. Influence of structure improvement of guide tubes and bundles in pressurized water reactor (PWR) on drop of control rods

    International Nuclear Information System (INIS)

    Shen Xiuzhong; Yu Pingan; Yang Guanyue

    1996-01-01

    In order to alleviate the cross hydraulic load on control rod guide tubes and bundles, some protective sleeves are added to those near the upper plenum outlet nozzles (4 symmetric bundles: 02-26, 03-25, 11-29, 12-28). In a 1/4 scale transparent model of the PWR upper plenum of Qinshan Nuclear Power Station, water was chosen as the fluid and hydraulic experiments with improved control rod guide tubes and bundles were carried out. The results were carefully compared with those of the experiments with unimproved control rod guide tubes and bundles. It is concluded that adding protective sleeves to the control rod guide tubes and bundles near the outlet nozzles will help to lighten the hydraulic load on them and make certain of the free movement and rapid dropping of control rods in the tubes and bundles in emergency by order

  2. Frequency, triggering factors and possible consequences of mass movements on outlet glaciers in Iceland.

    Science.gov (United States)

    Saemundsson, Thorsteinn; Margeirsson, Guðbjörn

    2016-04-01

    During the last 15 years several mass movements of various size and origin, e.g. rock avalanches, rock slides and debris slides have been observed to have fall on outlet glaciers in Iceland. This should not come as a surprise in this type of glacial environment, but in a way it does. When looking at the history only few mass movements are recorded to have fall on outlet glaciers in Iceland, during the decades before the year 2000 or since 1960. This "lack of mass movements" can be explained by the fact that fewer observations and monitoring were done in the past, but is it so or are we seeing increasing activity? Looking at the distribution of the known mass movements, two activity periods cam be identified. The former one around 1970 and the second one starting around 2000 and is still ongoing. Both of these periods are characterized by warmer climate leading to retreating phases of glaciers. Two larger mass movements are known from these two retreating periods. The former one occurred in January 1967. Then a large rockslide fell on the snout and into the glacial lake of the Steinholtsjökull outlet glacier in the northern side of the Eyjafjallajökull ice cap. The rockslide broke up the snout of the glacier and caused large floodwave bursting down the Steinholtsdalur valley transporting large volume of sediments down its path. The later one occurred in 2007, when a large rockavalanche fell on the Morsárjökull outlet glacier, in the southern side of the Vatnajökull ice cap. The avalanche debris covered around 1/5 of the glacier surface. Today the retreat and thinning of glaciers in Iceland are extremely rapid. The consequences of such a rapid retreat are e.g. unstable valley slopes surrounding the outlet glaciers, both in loose sediments and bedrock, thawing of mountain permafrost and not least formation of glacial lakes in front of the rapid retreating ice margins. Such conditions can become extremely hazardous, as seen by the above mentioned examples, both

  3. Greater access to fast-food outlets is associated with poorer bone health in young children.

    Science.gov (United States)

    Vogel, C; Parsons, C; Godfrey, K; Robinson, S; Harvey, N C; Inskip, H; Cooper, C; Baird, J

    2016-03-01

    A healthy diet positively influences childhood bone health, but how the food environment relates to bone development is unknown. Greater neighbourhood access to fast-food outlets was associated with lower bone mass among infants, while greater access to healthy speciality stores was associated with higher bone mass at 4 years. Identifying factors that contribute to optimal childhood bone development could help pinpoint strategies to improve long-term bone health. A healthy diet positively influences bone health from before birth and during childhood. This study addressed a gap in the literature by examining the relationship between residential neighbourhood food environment and bone mass in infants and children. One thousand one hundred and seven children participating in the Southampton Women's Survey, UK, underwent measurement of bone mineral density (BMD) and bone mineral content (BMC) at birth and 4 and/or 6 years by dual-energy X-ray absorptiometry (DXA). Cross-sectional observational data describing food outlets within the boundary of each participant's neighbourhood were used to derive three measures of the food environment: the counts of fast-food outlets, healthy speciality stores and supermarkets. Neighbourhood exposure to fast-food outlets was associated with lower BMD in infancy (β = -0.23 (z-score): 95% CI -0.38, -0.08) and lower BMC after adjustment for bone area and confounding variables (β = -0.17 (z-score): 95% CI -0.32, -0.02). Increasing neighbourhood exposure to healthy speciality stores was associated with higher BMD at 4 and 6 years (β = 0.16(z-score): 95% CI 0.00, 0.32 and β = 0.13(z-score): 95% CI -0.01, 0.26 respectively). The relationship with BMC after adjustment for bone area and confounding variables was statistically significant at 4 years, but not at 6 years. The neighbourhood food environment that pregnant mothers and young children are exposed may affect bone development during early childhood. If confirmed in

  4. An interactive physics-based unmanned ground vehicle simulator leveraging open source gaming technology: progress in the development and application of the virtual autonomous navigation environment (VANE) desktop

    Science.gov (United States)

    Rohde, Mitchell M.; Crawford, Justin; Toschlog, Matthew; Iagnemma, Karl D.; Kewlani, Guarav; Cummins, Christopher L.; Jones, Randolph A.; Horner, David A.

    2009-05-01

    It is widely recognized that simulation is pivotal to vehicle development, whether manned or unmanned. There are few dedicated choices, however, for those wishing to perform realistic, end-to-end simulations of unmanned ground vehicles (UGVs). The Virtual Autonomous Navigation Environment (VANE), under development by US Army Engineer Research and Development Center (ERDC), provides such capabilities but utilizes a High Performance Computing (HPC) Computational Testbed (CTB) and is not intended for on-line, real-time performance. A product of the VANE HPC research is a real-time desktop simulation application under development by the authors that provides a portal into the HPC environment as well as interaction with wider-scope semi-automated force simulations (e.g. OneSAF). This VANE desktop application, dubbed the Autonomous Navigation Virtual Environment Laboratory (ANVEL), enables analysis and testing of autonomous vehicle dynamics and terrain/obstacle interaction in real-time with the capability to interact within the HPC constructive geo-environmental CTB for high fidelity sensor evaluations. ANVEL leverages rigorous physics-based vehicle and vehicle-terrain interaction models in conjunction with high-quality, multimedia visualization techniques to form an intuitive, accurate engineering tool. The system provides an adaptable and customizable simulation platform that allows developers a controlled, repeatable testbed for advanced simulations. ANVEL leverages several key technologies not common to traditional engineering simulators, including techniques from the commercial video-game industry. These enable ANVEL to run on inexpensive commercial, off-the-shelf (COTS) hardware. In this paper, the authors describe key aspects of ANVEL and its development, as well as several initial applications of the system.

  5. Coolant mixing in LMFBR rod bundles and outlet plenum mixing transients. Progress report, December 1, 1975--February 29, 1976

    International Nuclear Information System (INIS)

    Todreas, N.E.; Golay, M.W.

    1976-01-01

    Progress is summarized in the following task areas: assessment of available data, experimental water mixing investigations, analytic model development, and analytical and experimental investigation of velocity and temperature fields in outlet plenum flow mixing

  6. Albanian and UK Consumers’ Perceptions of Farmers’ Markets and Supermarkets as Outlets for Organic Food: An Exploratory Study

    Directory of Open Access Journals (Sweden)

    Athina-Evera Qendro

    2015-05-01

    Full Text Available The purpose of this paper is to elicit UK and Albanian consumers’ perceptions of food outlets in order to understand their views on supermarkets and farmers’ markets as outlets for organic food. A qualitative research methodology was chosen as the best way to get an in-depth understanding of how consumers of these two different countries understand and evaluate buying organic food from two different food outlets. This exploratory research is a first step to find out how and why organic food is being bought in supermarkets and farmers’ markets. The results show that respondents associated organic with vegetables and fruit, that taste good, are healthy, and are free of pesticides and hormones. The importance of motives varies between the outlets they prefer for buying organic food. An interesting finding is the fact that Albanian respondents refer to the farmers’ markets as the villagers’ market.

  7. Coolant mixing in LMFBR rod bundles and outlet plenum mixing transients. Progress report, March 1, 1977--May 31, 1977

    International Nuclear Information System (INIS)

    Todreas, N.E.; Golay, M.W.; Wolf, L.

    1977-01-01

    Progress is summarized in the following tasks: (1) bundle flow studies (wrapped and bare rods); (2) subchannel flow studies (bare rods); (3) LMFBR outlet plenum flow mixing; and (4) theoretical determination of local temperature fields in LMFBR fuel rod bundles

  8. The effect of epoxidized soybean oil on mechanical and rheological properties of poly(butylene succinate)/lignin via vane extruder

    Science.gov (United States)

    Liu, Huanyu; Huang, Zhaoxia; Qu, Jinping; Meng, Cong

    2016-03-01

    Epoxidized Soybean Oil (ESO) have been used as the compatilizer in the Poly (butylene succinate)/lignin (PBS/lignin) composites. Compatibilized composites were fabricated by a novel vane extruder (VE) which can generate global and dynamic elongational flow. The effects of ESO on the mechanical, rheological properties and morphology of PBS/lignin were studied. The results indicated that the use of ESO had plasticizing effect on the matrix PBS while the addition reduced tensile strength. From SEM micrographs it could be clearly observed that there was a better interfacial adhesion between lignin and matrix. Meanwhile, rheological tests showed the incorporation of ESO improved its Newtonian behavior and can enhance PBS's flexibility.

  9. Expert Guide

    DEFF Research Database (Denmark)

    Heiselberg, Per

    , their benefits and limitations, economical feasibility and impact on energy savings, company image, comfort, productivity, building functionality and flexibility and gives guidance on design of these concepts, including integration of responsive building elements and HVAC-systems and build examples......This guide summarizes the work of Subtask B of IEA-ECBCS Annex 44 “Integrating Environmentally Responsive Elements in Buildings” and is based on the contributions from the participating countries. The publication is an official Annex report. With a focus on innovative building concepts...

  10. Alcohol outlet densities and alcohol price: the British Columbia experiment in the partial privatization of alcohol sales off-premise.

    Science.gov (United States)

    Treno, Andrew J; Ponicki, William R; Stockwell, Tim; Macdonald, Scott; Gruenewald, Paul J; Zhao, Jinhui; Martin, Gina; Greer, Alissa

    2013-05-01

    Alcohol beverage prices or taxes have been shown to be related to alcohol sales and use and related problems. What is not clear are the mechanisms underlying these relationships. This study examines the relationship between alcohol outlet density under conditions of the partial privatization of off-premise consumption in British Columbia (BC) occurring over the past decade. Two hypotheses are tested. First, reflecting basic supply-demand principles, greater geographic densities of alcohol outlets will be directly related to reductions in beverage prices in response to greater competition. Second, reflecting the effects of niche marketing and resulting market stratification, increased densities of private liquor stores will be especially related to reductions in beverage prices within this outlet category. Data were collected from: (i) a survey of BC private store prices and practices, (ii) alcohol outlet location information, and (iii) data on demographic characteristics. Multilevel models examine the relationships between prices at individual private liquor stores and the densities of government liquor stores, private liquor stores, bars, and restaurants, controlling for background demographics and geographic unit level effects. Spatial dependencies were also examined. Increased densities of private liquor stores were associated with lower mean prices of beer and all alcohol aggregated across brands at the store level. There appeared to be no outlet level effect on discounting patterns, however, with the mean price differences apparently reflecting differences in the quality of brands carried rather than unequal prices for any given brand. Increased densities of private off-sale alcohol outlets appear to result in lower prices charged at said establishments independently of other types of alcohol outlets suggesting that they represent an emerging marketing niche in the context of off-sale outlet privatization. Copyright © 2012 by the Research Society on

  11. Does neighborhood fast-food outlet exposure amplify inequalities in diet and obesity? A cross-sectional study12

    Science.gov (United States)

    Forouhi, Nita G; Griffin, Simon J; Brage, Søren; Wareham, Nicholas J

    2016-01-01

    Background: Greater exposures to fast-food outlets and lower levels of education are independently associated with less healthy diets and obesity. Little is known about the interplay between these environmental and individual factors. Objective: The purpose of this study was to test whether observed differences in fast-food consumption and obesity by fast-food outlet exposure are moderated by educational attainment. Design: In a population-based cohort of 5958 adults aged 29–62 y in Cambridgeshire, United Kingdom, we used educational attainment–stratified regression models to estimate the food-frequency questionnaire–derived consumption of energy-dense “fast foods” (g/d) typically sold in fast-food restaurants and measured body mass index (BMI; in kg/m2) across geographic information system–derived home and work fast-food exposure quartiles. We used logistic regression to estimate the odds of obesity (BMI ≥30) and calculated relative excess risk due to interaction (RERI) on an additive scale. Participant data were collected during 2005–2013 and analyzed in 2015. Results: Greater fast-food consumption, BMI, and odds of obesity were associated with greater fast-food outlet exposure and a lower educational level. Fast-food consumption and BMI were significantly different across education groups at all levels of fast-food outlet exposure (P fast-food outlet exposure amplified differences in fast-food consumption across levels of education. The relation between fast-food outlet exposure and obesity was only significant among those who were least educated (OR: 2.05; 95% CI: 1.08, 3.87; RERI = 0.88), which suggested a positive additive interaction between education and fast-food outlet exposure. Conclusion: These findings suggest that efforts to improve diets and health through neighborhood-level fast-food outlet regulation might be effective across socioeconomic groups and may serve to reduce observed socioeconomic inequalities in diet and obesity. PMID

  12. Does neighborhood fast-food outlet exposure amplify inequalities in diet and obesity? A cross-sectional study.

    Science.gov (United States)

    Burgoine, Thomas; Forouhi, Nita G; Griffin, Simon J; Brage, Søren; Wareham, Nicholas J; Monsivais, Pablo

    2016-06-01

    Greater exposures to fast-food outlets and lower levels of education are independently associated with less healthy diets and obesity. Little is known about the interplay between these environmental and individual factors. The purpose of this study was to test whether observed differences in fast-food consumption and obesity by fast-food outlet exposure are moderated by educational attainment. In a population-based cohort of 5958 adults aged 29-62 y in Cambridgeshire, United Kingdom, we used educational attainment-stratified regression models to estimate the food-frequency questionnaire-derived consumption of energy-dense "fast foods" (g/d) typically sold in fast-food restaurants and measured body mass index (BMI; in kg/m(2)) across geographic information system-derived home and work fast-food exposure quartiles. We used logistic regression to estimate the odds of obesity (BMI ≥30) and calculated relative excess risk due to interaction (RERI) on an additive scale. Participant data were collected during 2005-2013 and analyzed in 2015. Greater fast-food consumption, BMI, and odds of obesity were associated with greater fast-food outlet exposure and a lower educational level. Fast-food consumption and BMI were significantly different across education groups at all levels of fast-food outlet exposure (P fast-food outlet exposure amplified differences in fast-food consumption across levels of education. The relation between fast-food outlet exposure and obesity was only significant among those who were least educated (OR: 2.05; 95% CI: 1.08, 3.87; RERI = 0.88), which suggested a positive additive interaction between education and fast-food outlet exposure. These findings suggest that efforts to improve diets and health through neighborhood-level fast-food outlet regulation might be effective across socioeconomic groups and may serve to reduce observed socioeconomic inequalities in diet and obesity.

  13. Pemilihan food outlet sebagai faktor risiko berat badan lebih anak usia sekolah dasar di Kecamatan Tegalsari Surabaya

    OpenAIRE

    Renny Evelyn Hartono; BJ. Istiti Kandarina; Siti Helmyati

    2016-01-01

    ABSTRACTIntroduction: Overweight and obesity are conditions resulting from an imbalance of calories in the body that occur in a long time and cause more deaths than underweight. One of factors related is food pattern, which also infl uenced the selection of food outlets. Surabaya is an urban area so it has many types and characteristic s of food outlet. Elementary school (4, 5, 6) do not really depend on their parents, so their food consumption and physical activity began to vary. Objectives:...

  14. Simulation of a proposed emergency outlet from Devils Lake, North Dakota

    Science.gov (United States)

    Vecchia, Aldo V.

    2002-01-01

    From 1993 to 2001, Devils Lake rose more than 25 feet, flooding farmland, roads, and structures around the lake and causing more than $400 million in damages in the Devils Lake Basin. In July 2001, the level of Devils Lake was at 1,448.0 feet above sea level1, which was the highest lake level in more than 160 years. The lake could continue to rise to several feet above its natural spill elevation to the Sheyenne River (1,459 feet above sea level) in future years, causing extensive additional flooding in the basin and, in the event of an uncontrolled natural spill, downstream in the Red River of the North Basin as well. The outlet simulation model described in this report was developed to determine the potential effects of various outlet alternatives on the future lake levels and water quality of Devils Lake.Lake levels of Devils Lake are controlled largely by precipitation on the lake surface, evaporation from the lake surface, and surface inflow. For this study, a monthly water-balance model was developed to compute the change in total volume of Devils Lake, and a regression model was used to estimate monthly water-balance data on the basis of limited recorded data. Estimated coefficients for the regression model indicated fitted precipitation on the lake surface was greater than measured precipitation in most months, fitted evaporation from the lake surface was less than estimated evaporation in most months, and ungaged inflow was about 2 percent of gaged inflow in most months. Dissolved sulfate was considered to be the key water-quality constituent for evaluating the effects of a proposed outlet on downstream water quality. Because large differences in sulfate concentrations existed among the various bays of Devils Lake, monthly water-balance data were used to develop detailed water and sulfate mass-balance models to compute changes in sulfate load for each of six major storage compartments in response to precipitation, evaporation, inflow, and outflow from

  15. Utilization of Cupping Therapy in the Treatment of Vascular Thoracic Outlet Syndrome in a Collegiate Pitcher: A Case Study

    Directory of Open Access Journals (Sweden)

    Stephen A. Cage

    2017-12-01

    Full Text Available Objective: Present a clinical case detailing the effectiveness of dry cupping therapy in treating thoracic outlet syndrome. The utilization of dry cupping therapy on a 20-year-old collegiate baseball pitcher with diagnosed thoracic outlet syndrome is presented. Background: Thoracic outlet syndrome is a relatively rare musculoskeletal condition affecting 1/100,000 patients annually. Dry cupping therapy is an ancient therapeutic modality that utilizes various means of suction with the goal of decompressing myofascial layers. Treatment: Following diagnosis, patient was successfully treated in two weeks using dry cupping therapy. The patient experienced no further incidence of thoracic outlet syndrome symptoms and was able to complete the remainder of his competitive season. Uniqueness: The patient’s thoracic outlet syndrome was diagnosed at an early stage, leading to the need of clearance from a vascular specialist before returning to competition. To the author’s knowledge, there are currently no published case reports detailing the use of cupping therapy to treat thoracic outlet syndrome. Conclusion: Cupping therapy may be a viable treatment option when seeking to address tight musculature. Further research needs to be conducted to determine optimal parameters for cupping therapy as a therapeutic modality.

  16. Neighborhood Alcohol Outlet Density and Rates of Child Abuse and Neglect: Moderating Effects of Access to Substance Abuse Services

    Science.gov (United States)

    Morton, Cory M.; Simmel, Cassandra; Peterson, N. Andrew

    2014-01-01

    This study investigates the relationship between concentrations of on- and off-premises alcohol outlets and rates of child abuse and neglect. Additionally, the study seeks to locate protective features of a neighborhood's built environment by investigating the potentially moderating role that access to substance abuse treatment and prevention services plays in the relationship between alcohol outlet density and child maltreatment. Using a cross-sectional design, this ecological study utilized data from 163 census tracts in Bergen County, New Jersey, on reports of child abuse and neglect, alcohol outlets, substance abuse treatment and prevention facilities, and the United States Census to investigate the linkages between socioeconomic structure, alcohol availability, and access to substance abuse service facilities on rates of child abuse and neglect. Findings indicate areas with a greater concentration of on-premises alcohol outlets (i.e., bars) had higher rates of child neglect, and those with easier access to substance abuse services had lower rates of neglect, controlling for neighborhood demographic and socioeconomic structure. Additionally, the relationship between on-premises alcohol outlet density and rates of child neglect was moderated by the presence of substance abuse service facilities. A greater concentration of off-premises outlets (i.e., liquor stores) was associated with lower rates of physical abuse. Findings suggest that the built environment and socioeconomic structure of neighborhoods have important consequences for child well-being. The implications for future research on the structural features of neighborhoods that are associated with child well-being are discussed. PMID:24529493

  17. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    International Nuclear Information System (INIS)

    Mastora, I.; Remy-Jardin, M.; Remy, J.; Suess, C.; Scherf, C.; Guillot, J.P.

    2001-01-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)

  18. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    Energy Technology Data Exchange (ETDEWEB)

    Mastora, I.; Remy-Jardin, M.; Remy, J. [Dept. of Radiology, University Center Hospital Calmette, Lille (France); Medical Research Group, Lille (France); Suess, C.; Scherf, C. [Siemens Medical Systems, Forcheim (Germany); Guillot, J.P. [Dept. of Radiology, University Center Hospital Calmette, Lille (France)

    2001-04-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)

  19. Outlet Glacier-Ice Shelf-Ocean Interactions: Is the Tail Wagging the Dog?

    Science.gov (United States)

    Parizek, B. R.; Walker, R. T.; Rinehart, S. K.

    2009-12-01

    While the massive interior regions of the Antarctic and Greenland Ice Sheets are presently ``resting quietly", the lower elevations of many outlet glaciers are experiencing dramatic adjustments due to changes in ice dynamics and/or surface mass balance. Oceanic and/or atmospheric forcing in these marginal regions often leads to mass deficits for entire outlet basins. Therefore, coupling the wagging tail of ice-ocean interactions with the vast ice-sheet reservoirs is imperative for accurate assessments of future sea-level rise. To study ice-ocean dynamic processes, we couple an ocean-plume model that simulates ice-shelf basal melting rates based on temperature and salinity profiles combined with plume dynamics associated with the geometry of the ice-shelf cavity (following Jenkins, 1991 and Holland and Jenkins, 1999) with a two-dimensional, isothermal model of outlet glacier-ice shelf flow (as used in Alley et al., 2007; Walker et al., 2008; Parizek et al., in review). Depending on the assigned temperature and salinity profiles, the ocean model can simulate both water-mass end-members: either cold High Salinity Shelf Water (HSSW) or relatively warm Circumpolar Deep Water (CDW), as well as between-member conditions. Notably, the coupled system exhibits sensitivity to the initial conditions. In particular, melting concentrated near the grounding line has the greatest effect in forcing grounding-line retreat. Retreat is further enhanced by a positive feedback between the ocean and ice, as the focused melt near the grounding line leads to an increase in the local slope of the basal ice, thereby enhancing buoyancy-driven plume flow and subsequent melt rates.

  20. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-01-01

    Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641

  1. Combined diurnal variations of discharge and hydrochemistry of the Isunnguata Sermia outlet, Greenland Ice Sheet

    Science.gov (United States)

    Graly, Joseph; Harrington, Joel; Humphrey, Neil

    2017-05-01

    In order to examine daily cycles in meltwater routing and storage in the Isunnguata Sermia outlet of the Greenland Ice Sheet, variations in outlet stream discharge and in major element hydrochemistry were assessed over a 6-day period in July 2013. Over 4 days, discharge was assessed from hourly photography of the outlet from multiple vantages, including where midstream naled ice provided a natural gauge. pH, electrical conductivity, suspended sediment, and major element and anion chemistry were measured in samples of stream water collected every 3 h.Photography and stream observations reveal that although river width and stage have only slight diurnal variation, there are large diurnal changes in discharge shown by the doubling in width of what we term the active channel, which is characterized by large standing waves and fast flow. The concentration of dissolved solutes follows a sinusoidal diurnal cycle, except for large and variable increases in dissolved solutes during the stream's waning flow. Solute concentrations vary by ˜ 30 % between diurnal minima and maxima. Discharge maxima and minima lag temperature and surface melt by 3-7 h; diurnal solute concentration minima and maxima lag discharge by 3-6 h.This phase shift between discharge and solute concentration suggests that during high flow, water is either encountering more rock material or is stored in longer contact with rock material. We suggest that expansion of a distributed subglacial hydrologic network into seldom accessed regions during high flow could account for these phenomena, and for a spike of partial silicate reaction products during waning flow, which itself suggests a pressure threshold-triggered release of stored water.

  2. A porcine model of bladder outlet obstruction incorporating radio-telemetered cystometry.

    Science.gov (United States)

    Shaw, Matthew B; Herndon, Claude D; Cain, Mark P; Rink, Richard C; Kaefer, Martin

    2007-07-01

    To present a novel porcine model of bladder outlet obstruction (BOO) with a standardized bladder outlet resistance and real-time ambulatory radio-telemetered cystometry, as BOO is a common condition with many causes in both adults and children, with significant morbidity and occasional mortality, but attempts to model this condition in many animal models have the fundamental problem of standardising the degree of outlet resistance. BOO was created in nine castrated male pigs by dividing the mid-urethra; outflow was allowed through an implanted bladder drainage catheter containing a resistance valve, allowing urine to flow across the valve only when a set pressure differential was generated across the valve. An implantable radio-telemetered pressure sensor monitored the pressure within the bladder and abdominal cavity, and relayed this information to a remote computer. Four control pigs had an occluded bladder drainage catheter and pressure sensor placed, but were allowed to void normally through the native urethra. Intra-vesical pressure was monitored by telemetry, while the resistance valve was increased weekly, beginning with 2 cmH2O and ultimately reaching 10 cmH2O. The pigs were assessed using conventional cystometry under anaesthesia before death, and samples conserved in formalin for haematoxylin and eosin staining. The pigs had radio-telemetered cystometry for a median of 26 days. All telemetry implants functioned well for the duration of the experiment, but one pig developed a urethral fistula and was excluded from the study. With BOO the bladder mass index (bladder mass/body mass x 10 000) increased from 9.7 to 20 (P = 0.004), with a significant degree of hypertrophy of the detrusor smooth muscle bundles. Obstructed bladders were significantly less compliant than control bladders (8.3 vs 22.1 mL/cmH2O, P = 0.03). Telemetric cystometry showed that there was no statistically significance difference in mean bladder pressure between obstructed and control pigs

  3. Gastric Outlet Obstruction Caused by Foley Catheter: A Complication when Substituting for Commercial Gastrostomy Tubes

    Directory of Open Access Journals (Sweden)

    Amanda B. Lewis

    2018-01-01

    Full Text Available The technique of using percutaneous endoscopic gastrostomy (PEG for long-term enteral feeding is well established and commonly used. While the technique is relatively safe and simple, the gastrostomy tube itself may deteriorate or malfunction, requiring a replacement tube. We present a case of a 58-year-old woman who was found to have gastric outlet obstruction from the inflated balloon of a Foley catheter being used as a replacement for her PEG tube. This case illustrates a potential complication of using a Foley catheter in place of commercially available gastrostomy tubes.

  4. Quantitative detection of I-131 at the inlet and outlet of the Giessen municipality sewage works

    International Nuclear Information System (INIS)

    Leib, J.; Crecelius, R.; Pfeiff, H.; Faengewisch, G.L.

    1985-01-01

    During the sampling time, the mean quantities of the radioactive iodine delivered to the sewage works were measured to be 66 p.c. at the inlet and 28 p.c. at the outlet. Error sources of the procedure adopted for the study are assessment only of the overall inflow to the sewage treatment plant during sampling time, and lacking exactness of values for the detention period of the radioactive iodine in the sewage plant. Dispersion calculations made in addition to water examinations showed that the mean radiation dose as a result of the iodine discharges is far below the limits set by the Radiation Protection Ordinance. (orig./PW) [de

  5. Thoracic Outlet Syndrome in a Volleyball Player Due to Nonunion of the First Rib Fracture.

    Science.gov (United States)

    Puttmann, Kathleen T; Satiani, Bhagwan; Vaccaro, Patrick

    2016-11-01

    Fracture of the first rib with ensuing callus formation is a rare cause of thoracic outlet syndrome. We report a case of a 17-year-old female volleyball player who presented with months of chronic arm pain. Radiographic imaging demonstrated nonunion fracture of the first rib. Physical therapy had been unsuccessful in relieving the pain, and surgical management was performed with resection of the first rib through a transaxillary approach with complete resolution of symptoms. Inflammation surrounding such fractures may destroy tissue planes, making dissection more technically difficult.

  6. Flue gas moisture capacity calculation at the outlet of the condensation heat recovery unit

    Directory of Open Access Journals (Sweden)

    Galashov Nikolay

    2017-01-01

    Full Text Available As a result, study equation has been obtained which determine the flue gas moisture capacity at the outlet of the condensation heat recovery unit with an error of less than 1%. It possible to at the temperature of the flue gas below the dew point and the known air-fuel ratio efficient. The equation can be used to calculate plants operating on products of gas combustion without Use of tables and programs for calculating the water-vapor saturation pressure.

  7. Sudden increase in tidal response linked to calving and acceleration at a large Greenland outlet glacier

    DEFF Research Database (Denmark)

    de Juan, Julia; Elósegui, Pedro; Nettles, Meredith

    2010-01-01

    strongly with the step-like increases in glacier speed and longitudinal strain rate associated with glacial earthquakes. The enhanced response to the ocean tides may be explained by a temporary disruption of the subglacial drainage system and a concomitant reduction of the friction at the ice......Large calving events at Greenland's largest outlet glaciers are associated with glacial earthquakes and near-instantaneous increases in glacier flow speed. At some glaciers and ice streams, flow is also modulated in a regular way by ocean tidal forcing at the terminus. At Helheim Glacier, analysis...

  8. Comercio móvil: comparativa experimental, tienda especializada en moda Vs tienda outlet

    OpenAIRE

    Ausín Rodríguez, Noelia

    2014-01-01

    El comercio electrónico y en concreto, el comercio móvil, se están consolidando como nuevas formas de adquisición de productos y servicios. En este trabajo, se estudiarán los hábitos de los consumidores en la búsqueda de información sobre productos y servicios, así como en la compra, desde distintos dispositivos. A su vez, se realizará una comparativa experimental simulando la compra a través de la APP de una tienda especializada en moda (Zara) y la APP de una tienda outlet (Privalia), ...

  9. Mathematical, numerical and experimental analysis of the swirling flow at a Kaplan runner outlet

    Science.gov (United States)

    Muntean, S.; Ciocan, T.; Susan-Resiga, R. F.; Cervantes, M.; Nilsson, H.

    2012-11-01

    The paper presents a novel mathematical model for a-priori computation of the swirling flow at Kaplan runners outlet. The model is an extension of the initial version developed by Susan-Resiga et al [1], to include the contributions of non-negligible radial velocity and of the variable rothalpy. Simple analytical expressions are derived for these additional data from three-dimensional numerical simulations of the Kaplan turbine. The final results, i.e. velocity components profiles, are validated against experimental data at two operating points, with the same Kaplan runner blades opening, but variable discharge.

  10. Consumer Preferences for Animal Source Foods in Uganda: Quality, Retail Forms and Retail Outlets

    Directory of Open Access Journals (Sweden)

    Nadhem Mtimet

    2013-10-01

    Full Text Available This paper presents the results of a rapid consumer survey undertaken in Uganda. The survey aimed at identifying preferred quality and safety attributes, retail forms and retail outlets for major livestock products and by type of consumers. Results of the survey, combined with nationally representative household datasets, allows description of both the quantitative and qualitative dimensions of the developing market for animal-source foods, which is anticipated to provide major business opportunities for small-scale livestock producers in the short and medium terms.

  11. Mathematical, numerical and experimental analysis of the swirling flow at a Kaplan runner outlet

    International Nuclear Information System (INIS)

    Muntean, S; Ciocan, T; Susan-Resiga, R F; Cervantes, M; Nilsson, H

    2012-01-01

    The paper presents a novel mathematical model for a-priori computation of the swirling flow at Kaplan runners outlet. The model is an extension of the initial version developed by Susan-Resiga et al [1], to include the contributions of non-negligible radial velocity and of the variable rothalpy. Simple analytical expressions are derived for these additional data from three-dimensional numerical simulations of the Kaplan turbine. The final results, i.e. velocity components profiles, are validated against experimental data at two operating points, with the same Kaplan runner blades opening, but variable discharge.

  12. Thoracic Outlet Syndrome Caused by Hydatid Cyst of the First Rib-Rare But Important

    OpenAIRE

    Levy Faber, Dan; Best, Lael-Anson; Militianu, Daniela; Ben Nun, Alon

    2010-01-01

    Hydatid cysts are usually located in the liver and lungs. Skeletal echinococcosis is relatively rare and that of the rib is exceptional. Less than 50 cases of costal echinococcosis have been reported in the literature so far. To our knowledge, only one case report of thoracic outlet syndrome due to echinococcal cyst in the first rib was described in 1995. Accurate pre-operative diagnosis is important but may be challenging in some cases. Reported here is a case of echinococcosis of the first ...

  13. Ranking of conventional X-ray diagnosis and phlebography in the thoracic outlet syndrome (TOS)

    International Nuclear Information System (INIS)

    Vahlensieck, M.; Beltz, L.

    1991-01-01

    The compression of the neurovascular bundle of the upper limb (thoracic outlet syndrome, TOS) can be caused by osseous, muscular, fibrous, tumorous and habitual abnormalities of the cervicothoracic junction. Osseous causes can be shown in a conventional x-ray of the cervi cothoracic junction. In about 40% of the cases there is a venous stenosis which can be proved by means of phlebography in a special patient position (provocation position). The type of stenosis and location provides information on the cause of it. We examined 34 patients. (orig.) [de

  14. Positioning and tail rotor of a small horizontal axis wind turbine of due to the influence of drag coefficient and lift affecting vane cola

    International Nuclear Information System (INIS)

    Farinnas Wong, E. Y.; Jauregui Rigo, S.; Betancourt Mena, J.

    2009-01-01

    In the present investigation was carried out an assessment on the state of technology on guidance systems and tail protection when used in small horizontal axis wind turbines, work was improved methodological approach for the development of guidance systems queue by time of these machines, to incorporate the use of coefficients of lift and drag behavior varies according to the aspect ratio, using the principles of continuum mechanics and CFD methods. Two versions are analyzed , original and updated, the wind turbine CEET-01, on which the author would have been granted a Certificate of Patent of Invention and one of Industrial Model, the updated version was derived from the procedure proposed by the author, this presents a holder for the longest vane and a larger area in the vane. In addition to analyzing the amount and cost of power generated and the capacity factor at three locations in the province of Villa Clara it was concluded that the updated variant of the turbine CEET-01 is superior to the original

  15. A cross-sectional analysis of the relationship between tobacco and alcohol outlet density and neighbourhood deprivation.

    Science.gov (United States)

    Shortt, Niamh K; Tisch, Catherine; Pearce, Jamie; Mitchell, Richard; Richardson, Elizabeth A; Hill, Sarah; Collin, Jeff

    2015-10-05

    There is a strong socio-economic gradient in both tobacco-and alcohol-related harm. One possible factor contributing to this social gradient may be greater availability of tobacco and alcohol in more socially-deprived areas. A higher density of tobacco and alcohol outlets is not only likely to increase supply but also to raise awareness of tobacco/alcohol brands, create a competitive local market that reduces product costs, and influence local social norms relating to tobacco and alcohol consumption. This paper examines the association between the density of alcohol and tobacco outlets and neighbourhood-level income deprivation. Using a national tobacco retailer register and alcohol licensing data this paper calculates the density of alcohol and tobacco retail outlets per 10,000 population for small neighbourhoods across the whole of Scotland. Average outlet density was calculated for neighbourhoods grouped by their level of income deprivation. Associations between outlet density and deprivation were analysed using one way analysis of variance. There was a positive linear relationship between neighbourhood deprivation and outlets for both tobacco (p sales alcohol (p sales and on-sales alcohol outlets. The social gradient evident in alcohol and tobacco supply may be a contributing factor to the social gradient in alcohol- and tobacco-related disease. Policymakers should consider such gradients when creating tobacco and alcohol control policies. The potential contribution to public health, and health inequalities, of reducing the physical availability of both alcohol and tobacco products should be examined in developing broader supply-side interventions.

  16. Supermarket and fast-food outlet exposure in Copenhagen: associations with socio-economic and demographic characteristics.

    Science.gov (United States)

    Svastisalee, Chalida M; Nordahl, Helene; Glümer, Charlotte; Holstein, Bjørn E; Powell, Lisa M; Due, Pernille

    2011-09-01

    To investigate whether exposure to fast-food outlets and supermarkets is socio-economically patterned in the city of Copenhagen. The study was based on a cross-sectional multivariate approach to examine the association between the number of fast-food outlets and supermarkets and neighbourhood-level socio-economic indicators. Food business addresses were obtained from commercial and public business locators and geocoded using a geographic information system for all neighbourhoods in the city of Copenhagen (n 400). The regression of counts of fast-food outlets and supermarkets v. indicators of socio-economic status (percentage of recent immigrants, percentage without a high-school diploma, percentage of the population under 35 years of age and average household income in Euros) was performed using negative binomial analysis. Copenhagen, Denmark. The unit of analysis was neighbourhood (n 400). In the fully adjusted models, income was not a significant predictor for supermarket exposure. However, neighbourhoods with low and mid-low income were associated with significantly fewer fast-food outlets. Using backwise deletion from the fully adjusted models, low income remained significantly associated with fast-food outlet exposure (rate ratio = 0·66-0·80) in the final model. In the city of Copenhagen, there was no evidence of spatial patterning of supermarkets by income. However, we detected a trend in the exposure to fast-food outlets, such that neighbourhoods in the lowest income quartile had fewer fast-food outlets than higher-income neighbourhoods. These findings have similarities with studies conducted in the UK, but not in the USA. The results suggest there may be socio-economic factors other than income associated with food exposure in Europe.

  17. Have drivers at alcohol outlets changed their behavior after the new traffic law?

    Directory of Open Access Journals (Sweden)

    Raquel B. De Boni

    2014-03-01

    Full Text Available Objective: In an attempt to reduce high levels of traffic crashes, a new legislation was approved in Brazil in 2008. This study aimed to assess behavioral change among drivers who had drunk at alcohol outlets (AO after implementation of the law. Method: A three-stage probability sampling survey was conducted in Porto Alegre, state of Rio Grande do Sul, Brazil. Individuals seen leaving AOs after drinking were approached (n=3,018. Selected drivers (n=683 answered a structured interview, were breathalyzed, and had saliva specimens collected for drug screening. Results: Overall, 60.3% (SE 4.5 of drivers reported they did not change their behavior. Among those who reported behavioral changes, most reported drinking less as their main strategy toward safer driving behavior. Variables independently associated with behavior change included having drunk at a high outlet density area (odds ratio [OR] 1.7 [1.1-2.8] and having a favorable opinion about the law (OR 4.3 [2.1-8.9]. Conclusions: Our findings suggest that awareness of the law has not been enough to promote behavioral change. As most drivers had a favorable opinion of the law and this variable was found to be the strongest predictor of behavior change, efforts to better integrate education and enforcement seem to be pivotal and might be well received by the population.

  18. A Numerical Analysis of Droplet Breakup in Asymmetric T-Junctions with Different Outlet Pressure Gradients

    Science.gov (United States)

    Cheng, Way Lee; Han, Arum; Sadr, Reza

    2016-11-01

    Droplet splitting is the breakup of a parent droplet into two or more daughter droplets of desired sizes. It is done to improve production efficiency and investigational capacity in microfluidic devices. Passive splitting is the breakup of droplets into precise volume ratios at predetermined locations without external power sources. In this study, a 3-D simulation was conducted using the Volume-of-Fluid method to analysis the breakup process of a droplet in asymmetric T-junctions with different outlet arm lengths. The arrangement allows a droplet to be split into two smaller droplets of different sizes, where the volumetric ratio of the daughter droplets depends on the length ratios of the outlet arms. The study identified different breakup regimes such as primary, transition, bubble and non-breakup under different flow conditions and channel configurations. Furthermore, a close analysis to the primary breakup regimes were done to determine the breakup mechanisms at various flow conditions. The analysis show that the breakup mechanisms in asymmetric T-junctions is different than a regular split. A pseudo-phenomenological model for the breakup criteria was presented at the end. The model was an expanded version to a theoretically derived model for the symmetric droplet breakup. The Qatar National Research Fund (a member of the Qatar Founda- tion), under Grant NPRP 5-671-2-278, supported this work.

  19. Field validation of food outlet databases: the Latino food environment in North Carolina, USA.

    Science.gov (United States)

    Rummo, Pasquale E; Albrecht, Sandra S; Gordon-Larsen, Penny

    2015-04-01

    Obtaining valid, reliable measures of food environments that serve Latino communities is important for understanding barriers to healthy eating in this at-risk population. The primary aim of the study was to examine agreement between retail food outlet data from two commercial databases, Nielsen TDLinx (TDLinx) for food stores and Dun & Bradstreet (D&B) for food stores and restaurants, relative to field observations of food stores and restaurants in thirty-one census tracts in Durham County, NC, USA. We also examined differences by proportion of Hispanic population (Spanish language. One hundred and seventy-four food stores and 337 restaurants in Durham County, NC, USA. We found that overall sensitivity of food store listings in TDLinx was higher (64 %) than listings in D&B (55 %). Twenty-five food stores were characterized by auditors as Latino food stores, with 20 % identified in TDLinx, 52 % in D&B and 56 % in both sources. Overall sensitivity of restaurants (68 %) was higher than sensitivity of Latino restaurants (38 %) listed in D&B. Sensitivity did not differ substantially by Hispanic composition of neighbourhoods. Our findings suggest that while TDLinx and D&B commercial data sources perform well for total food stores, they perform less well in identifying small and independent food outlets, including many Latino food stores and restaurants.

  20. Exclusive double outlet right ventricle with atrioventricular concordance and pulmonary stenosis. Results of reconstructive surgery.

    Science.gov (United States)

    Busquet, J; Fontan, F; Choussat, A; Caianiello, G; Fernandez, G

    1988-01-01

    Double outlet right ventricle associated with atrioventricular concordance, pulmonary stenosis and situs solitus of the atria is a subset of double outlet right ventricle related through the surgical treatment. From 1974 to 1985, 14 patients, 5 males, 9 females (mean age 8.9 years, range 13 months-22 years) were operated upon. All patients had infundibular stenosis and normal or large pulmonary arteries. The apex of the heart was to the right in 2 patients, the right and left ventricles were superior and inferior in 2 patients and 1 patient had both anomalies. The ventricular septal defect was subaortic in 11 patients (aorto-mitral discontinuity in 5) and non-committed in 3 patients. Three patients had 2 ventricular septal defects. The aorta was anterior in 3 patients and to the right of the pulmonary artery in 11 patients. All patients, through a transventricular and transatrial approach, had a reconstructive surgery. In 3 patients, an aortic homograft valved conduit was used. One patient had the ventricular septal defect enlarged. There was one early death (7.1%) from high residual right ventricle pressure and no late death. One patient had a transient atrioventricular block. One patient was reoperated upon for a residual ventricular septal defect. All survivors had a good clinical result. Re-evaluation in 8 patients confirmed excellent haemodynamics: the right ventricle to pulmonary artery pressure gradient decreased from 80 mm Hg (range 60-95) preoperatively to 24 mm Hg (range 3-32) postoperatively.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Bilateral Upper Extremity DVT in a 43-Year-Old Man: Is It Thoracic Outlet Syndrome?!

    Directory of Open Access Journals (Sweden)

    Hadoun Jabri

    2014-01-01

    Full Text Available Recurrent deep venous thrombosis, involving bilateral upper extremities, is an extremely rare phenomenon. We are presenting a 43-year-old man who was diagnosed with left upper extremity deep vein thrombosis (UEDVT and was treated with anticoagulation and surgical decompression in 2004. 9 years later, he presented with right arm swelling and was diagnosed with right UEDVT using US venous Doppler. Venogram showed compression of the subclavian vein by the first rib, diagnosing thoracic outlet syndrome (TOS. He was treated with anticoagulation and local venolysis and later by surgical decompression of the subclavian vein. Bilateral UEDVT, as mentioned above, is an extremely rare condition that is uncommonly caused by TOS. To our knowledge, we are reporting the first case of bilateral UEDVT due to TOS. Diagnosis usually starts with US venous Doppler to detect the thrombosis, followed by the gold standard venogram to locate the area of obstruction and lyse the thrombus if needed. The ultimate treatment for TOS remains surgical decompression of the vascular bundle at the thoracic outlet.

  2. Measurement of heat and momentum eddy diffusivities in recirculating LMFBR outlet plenum flows

    International Nuclear Information System (INIS)

    Manno, V.P.; Golay, M.W.

    1978-06-01

    An optical technique has been developed for the measurement of the eddy diffusivity of heat in a transparent flowing medium. The method uses a combination of two established measurement tools: a Mach-Zehnder interferometer for the monitoring of turbulently fluctuating temperature and a Laser Doppler Anemometer (LDA) for the measurement of turbulent velocity fluctuations. The technique is applied to the investigation of flow fields characteristic of the LMFBR outlet plenum. The study is accomplished using air as the working fluid in a small scale Plexiglas test section. Lows are introduced into both the 1 / 15 scale FFTF outlet plenum and the 3 / 80 scale CRBR geometry plenum at inlet Reynolds numbers of 22,000. Measurements of the eddy diffusivity of heat and the eddy diffusivity of momentum are performed at a total of 11 measurement stations. Significant differences of the turbulence parameters are found between the two geometries, and the higher chimney structure of the CRBR case is found to be the major cause of the distinction. Spectral intensity studies of the fluctuating electronic analog signals of velocity and temperature are also performed. Error analysis of the overall technique indicates an experimental error of 10% in the determination of the eddy diffusivity of heat and 6% in the evaluation of turbulent momentum viscosity. In general it is seen that the turbulence in the cases observed is not isotropic, and use of isotropic turbulent heat and momentum diffusivities in transport modelling would not be a valid procedure

  3. Quantifying the Impacts of Outlet Control Structures on Lake Hydrology and Ecology

    Science.gov (United States)

    Budd, B. M.; Kendall, A. D.; Martin, S. L.; Hyndman, D. W.

    2012-12-01

    There have been limited studies of the impacts of lake level control structures on stream ecology and lake property erosion. We examine the influence of historical lake level management strategies on Higgins Lake in Michigan, which is regionally known for recreation, fisheries, and scenery. Lake control structures have potentially increased shoreline erosion and seasonally-reduced flow through the outlets, likely impacting fish habitat. Concerns over these issues spurred local land owners to seek a study on the possible hydrologic and ecological impacts of the removal or modification of the control structure. Bathymetry maps are fundamental to understanding and managing lake ecosystems. From the 1930's through the 1950's, these maps were developed for thousands of Michigan inland lakes using soundings lowered through holes cut in winter lake ice. Increased land use change and alterations of lake outlets have likely modified erosion and sedimentation rates of these lake systems. Our research includes bathymetry surveys of Higgins Lake using an Acoustic Doppler Current Profiler (ADCP) and side-scan sonar. The new higher-resolution bathymetry serves as the basis for simulating impacts of potential changes in lake management, on a verity of inpoint including shoreline position and fish habitat.

  4. Epigastric heteropagus associated with an omphalocele and double outlet right ventricle

    Directory of Open Access Journals (Sweden)

    Tatsuma Sakaguchi

    2015-10-01

    Full Text Available Incomplete or asymmetrical conjoined twins are extremely rare congenital anomalies. We report a case of epigastric heteropagus associated with an omphalocele and double outlet right ventricle. The cystic legion of the epigastrium was detected in our patient by an ultrasound scan at 28 weeks' gestation. He was born at 37 weeks' gestation by scheduled caesarean section. A parasite with an incomplete head and lower limb was attached to the epigastrium of the autosite. Surgical separation of the parasite and silo placement for an omphalocele was successfully performed on the 4th day of life. He underwent secondary surgical closure of the omphalocele on the 10th day. For treatment of the cardiac anomaly, he underwent an operation of Blalock–Taussig shunt because of pulmonary artery stenosis at the age of 3 months and correction of double outlet right ventricle at the age of 10 months. At the 20-month follow-up, he was alive and showed a normal growth pattern.

  5. A cross sectional study investigating the association between exposure to food outlets and childhood obesity in Leeds, UK.

    Science.gov (United States)

    Griffiths, Claire; Frearson, Anna; Taylor, Adam; Radley, Duncan; Cooke, Carlton

    2014-12-06

    Current UK policy in relation to the influence of the 'food environment' on childhood obesity appears to be driven largely on assumptions or speculations because empirical evidence is lacking and findings from studies are inconsistent. The aim of this study was to investigate the number of food outlets and the proximity of food outlets in the same sample of children, without solely focusing on fast food. Cross sectional study over 3 years (n = 13,291 data aggregated). Body mass index (BMI) was calculated for each participant, overweight and obesity were defined as having a BMI >85(th) (sBMI 1.04) and 95(th) (sBMI 1.64) percentiles respectively (UK90 growth charts). Home and school neighbourhoods were defined as circular buffers with a 2 km Euclidean radius, centred on these locations. Commuting routes were calculated using the shortest straight line distance, with a 2 km buffer to capture varying routes. Data on food outlet locations was sourced from Leeds City Council covering the study area and mapped against postcode. Food outlets were categorised into three groups, supermarkets, takeaway and retail. Proximity to the nearest food outlet in the home and school environmental domain was also investigated. Age, gender, ethnicity and deprivation (IDACI) were included as covariates in all models. There is no evidence of an association between the number of food outlets and childhood obesity in any of these environments; Home Q4 vs. Q1 OR = 1.11 (95% CI = 0.95-1.30); School Q4 vs. Q1 OR = 1.00 (95% CI 0.87 - 1.16); commute Q4 vs. Q1 OR = 0.1.00 (95% CI 0.83 - 1.20). Similarly there is no evidence of an association between the proximity to the nearest food outlet and childhood obesity in the home (OR = 0.77 [95% CI = 0.61 - 0.98]) or the school (OR = 1.01 [95% CI 0.84 - 1.23]) environment. This study provides little support for the notion that exposure to food outlets in the home, school and commuting neighbourhoods increase the risk of obesity

  6. Associations between childhood obesity and the availability of food outlets in the local environment: a retrospective cross-sectional study.

    Science.gov (United States)

    Miller, Laura J; Joyce, Sarah; Carter, Shannon; Yun, Grace

    2014-01-01

    Examine whether individual-level childhood obesity is related to residential availability of fast food and healthy food outlets. Retrospective cross-sectional study. Perth, Western Australia. A total of 1850 children aged 5 to 15 years in 2005-2010 who participated in the Western Australian Health and Wellbeing Surveillance System survey. Geographical Information Systems were used to calculate a range of measures of fast food and healthy food outlet access and availability. For example, distance to nearest and access and density measures within 800 m and 3 km of each child's residence were all tested. Multivariate logistic regression analysis, controlling for individual-level sociodemographic factors and lifestyle behaviors. An increasing number of healthy food outlets within 800 m of a child's home was associated with a significantly reduced risk of being overweight/obese in all models tested. After controlling for age, physical activity, time spent sedentary, weekly takeaway consumption, area disadvantage, and count of fast food outlets, each additional healthy food outlet within 800 m was associated with a 20% decrease in the likelihood of a child being overweight or obese (odds ratio: .800, 95% confidence intervals: .686-.933). The local food environment around children's homes has an independent effect on child weight status. These findings highlight the importance of the built environment as a potential contributor towards child health, which should be considered when developing community health promotion programs.

  7. Map-based prediction of organic carbon in headwater streams improved by downstream observations from the river outlet

    Science.gov (United States)

    Temnerud, J.; von Brömssen, C.; Fölster, J.; Buffam, I.; Andersson, J.-O.; Nyberg, L.; Bishop, K.

    2016-01-01

    In spite of the great abundance and ecological importance of headwater streams, managers are usually limited by a lack of information about water chemistry in these headwaters. In this study we test whether river outlet chemistry can be used as an additional source of information to improve the prediction of the chemistry of upstream headwaters (size interquartile range (IQR)) of headwater stream TOC for a given catchment, based on a large number of candidate variables including sub-catchment characteristics from GIS, and measured river chemistry at the catchment outlet. The best candidate variables from the PLS models were then used in hierarchical linear mixed models (MM) to model TOC in individual headwater streams. Three predictor variables were consistently selected for the MM calibration sets: (1) proportion of forested wetlands in the sub-catchment (positively correlated with headwater stream TOC), (2) proportion of lake surface cover in the sub-catchment (negatively correlated with headwater stream TOC), and (3) river outlet TOC (positively correlated with headwater stream TOC). Including river outlet TOC improved predictions, with 5-15 % lower prediction errors than when using map information alone. Thus, data on water chemistry measured at river outlets offer information which can complement GIS-based modelling of headwater stream chemistry.

  8. COATING ALTERNATIVES GUIDE (CAGE) USER'S GUIDE

    Science.gov (United States)

    The guide provides instructions for using the Coating Alternatives GuidE (CAGE) software program, version 1.0. It assumes that the user is familiar with the fundamentals of operating an IBM-compatible personal computer (PC) under the Microsoft disk operating system (MS-DOS). CAGE...

  9. Anti-malarial landscape in Myanmar: results from a nationally representative survey among community health workers and the private sector outlets in 2015/2016.

    Science.gov (United States)

    Thein, Si Thu; Khin, Hnin Su Su; Thi, Aung

    2017-04-25

    In 2015/2016, an ACTwatch outlet survey was implemented to assess the anti-malarial and malaria testing landscape in Myanmar across four domains (Eastern, Central, Coastal, Western regions). Indicators provide an important benchmark to guide Myanmar's new National Strategic Plan to eliminate malaria by 2030. This was a cross-sectional survey, which employed stratified cluster-random sampling across four regions in Myanmar. A census of community health workers (CHWs) and private outlets with potential to distribute malaria testing and/or treatment was conducted. An audit was completed for all anti-malarials, malaria rapid diagnostic tests. A total of 28,664 outlets were approached and 4416 met the screening criteria. The anti-malarial market composition comprised CHWs (41.5%), general retailers (27.9%), itinerant drug vendors (11.8%), pharmacies (10.9%), and private for-profit facilities (7.9%). Availability of different anti-malarials and diagnostic testing among anti-malarial-stocking CHWs was as follows: artemisinin-based combination therapy (ACT) (81.3%), chloroquine (67.0%), confirmatory malaria test (77.7%). Less than half of the anti-malarial-stocking private sector had first-line treatment in stock: ACT (41.7%) chloroquine (41.8%), and malaria diagnostic testing was rare (15.4%). Oral artemisinin monotherapy (AMT) was available in 27.7% of private sector outlets (Western, 54.1%; Central, 31.4%; Eastern; 25.0%, Coastal; 15.4%). The private-sector anti-malarial market share comprised ACT (44.0%), chloroquine (26.6%), and oral AMT (19.6%). Among CHW the market share was ACT (71.6%), chloroquine (22.3%); oral AMT (3.8%). More than half of CHWs could correctly state the national first-line treatment for uncomplicated falciparum and vivax malaria (59.2 and 56.9%, respectively) compared to the private sector (15.8 and 13.2%, respectively). Indicators on support and engagement were as follows for CHWs: reportedly received training on malaria diagnosis (60.7%) or

  10. Wind-tunnel calibration of a combined pitot-static tube and vane-type flow-angularity indicator at Mach numbers of 1.61 and 2.01

    Science.gov (United States)

    Sinclair, Archibald R; Mace, William D

    1956-01-01

    A limited calibration of a combined pitot-static tube and vane-type flow-angularity indicator has been made in the Langley 4- by 4-foot supersonic pressure tunnel at Mach numbers of 1.61 and 2.01. The results indicated that the angle-of-yaw indications were affected by unsymmetric shock effects at low angles of attack.

  11. R/S analysis based study on long memory about CODMn in Poyang Lake Inlet and Outlet

    Science.gov (United States)

    Wang, Lili

    2018-02-01

    Rescaled range analysis (R/S) is applied to the long memory behavior analysis of water CODMn series in Poyang Lake Inlet and Outlet in China. The results show that these CODMn series are characterized by long memory, and the characteristics have obvious differences between the Lake Inlet and Outlet. Our findings suggest that there was an obvious scale invariance, namely CODMn series in Lake Inlet for 13 weeks and CODMn in Lake Outlet for 17 weeks. Both displayed a two-power-law distribution and a similar high long memory. We made a preliminary explanation for the existence of the boundary point tc , using self-organized criticality. This work can be helpful to improvement of modelling of lake water quality.

  12. Tobacco retail outlet restrictions: health and cost impacts from multistate life-table modelling in a national population.

    Science.gov (United States)

    Pearson, Amber L; Cleghorn, Christine L; van der Deen, Frederieke S; Cobiac, Linda J; Kvizhinadze, Giorgi; Nghiem, Nhung; Blakely, Tony; Wilson, Nick

    2016-09-22

    Since there is some evidence that the density and distribution of tobacco retail outlets may influence smoking behaviours, we aimed to estimate the impacts of 4 tobacco outlet reduction interventions in a country with a smoke-free goal: New Zealand (NZ). A multistate life-table model of 16 tobacco-related diseases, using national data by sex, age and ethnicity, was used to estimate quality-adjusted life years (QALYs) gained and net costs over the remainder of the 2011 NZ population's lifetime. The outlet reduction interventions assumed that increased travel costs can be operationalised as equivalent to price increases in tobacco. All 4 modelled interventions led to reductions of >89% of current tobacco outlets after the 10-year phase-in process. The most effective intervention limited sales to half of liquor stores (and nowhere else) at 129 000 QALYs gained over the lifetime of the population (95% UI: 74 100 to 212 000, undiscounted). The per capita QALY gains were up to 5 times greater for Māori (indigenous population) compared to non-Māori. All interventions were cost-saving to the health system, with the largest saving for the liquor store only intervention: US$1.23 billion (95% UI: $0.70 to $2.00 billion, undiscounted). These tobacco outlet reductions reduced smoking prevalence, achieved health gains and saved health system costs. Effects would be larger if outlet reductions have additional spill-over effects (eg, smoking denormalisation). While these interventions were not as effective as tobacco tax increases (using the same model), these and other strategies could be combined to maximise health gain and to maximise cost-savings to the health system. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Neighborhood alcohol outlet density and rates of child abuse and neglect: moderating effects of access to substance abuse services.

    Science.gov (United States)

    Morton, Cory M; Simmel, Cassandra; Peterson, N Andrew

    2014-05-01

    This study investigates the relationship between concentrations of on- and off-premises alcohol outlets and rates of child abuse and neglect. Additionally, the study seeks to locate protective features of a neighborhood's built environment by investigating the potentially moderating role that access to substance abuse treatment and prevention services plays in the relationship between alcohol outlet density and child maltreatment. Using a cross-sectional design, this ecological study utilized data from 163 census tracts in Bergen County, New Jersey, on reports of child abuse and neglect, alcohol outlets, substance abuse treatment and prevention facilities, and the United States Census to investigate the linkages between socioeconomic structure, alcohol availability, and access to substance abuse service facilities on rates of child abuse and neglect. Findings indicate areas with a greater concentration of on-premises alcohol outlets (i.e., bars) had higher rates of child neglect, and those with easier access to substance abuse services had lower rates of neglect, controlling for neighborhood demographic and socioeconomic structure. Additionally, the relationship between on-premises alcohol outlet density and rates of child neglect was moderated by the presence of substance abuse service facilities. A greater concentration of off-premises outlets (i.e., liquor stores) was associated with lower rates of physical abuse. Findings suggest that the built environment and socioeconomic structure of neighborhoods have important consequences for child well-being. The implications for future research on the structural features of neighborhoods that are associated with child well-being are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Radiological evaluation of double-outlet right ventricle - An analysis of cinecardioangiography in 44 cases -

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheong Hee; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1984-03-15

    Double-outlet right ventricle is defined as follows: both great arteries arise completely or nearly completely from the right ventricle; neither semilunar valve is in fibrous continuity with either atrioventricular valve; and usually a ventricular septal defect is present and the only outlet from the left ventricle. A total of 44 cases of double-outlet right ventricle is analyzed, in which cineangiocardiographies were done at the Department of Radiology, Seoul National University Hospital in recent 4 year and 6 months, with specific reference to the segmental combinations, the height of conus, the relationship of great arteries, the location of ventricular septal defects, and associated anomalies. The results were as follows; 1. Among 44 cases, 36 cases had normal cardiac position, 4 cases had dextrocardia with situs inversus 2 cases had dextrocardia with situs solitus, 1 case had levocardia with situs inversus, and another 1 case had mesocardia with situs ambiguus. 2. Segmental sets were [S,D,D] in 36 cases, [I,L,L] in 3 cases, [I,D,D] in 2 cases, [S,D,L], [S,L,L] and [A,D,D] in 1 case respectively. 3. All cases had bilateral conus. Aortic valve rings were same level as pulmonary valve rings in 25 cases, lower than pulmonary valve rings in 17 cases in which 15 cases were type A., and higher than pulmonary valve rings in 2 cases. 4. The relation of the great arteries were normal in 15 cases, side-by-side in 13 cases, dextromalposition in 13 cases, and levomal position in 3 cases. 5. The position of the ventricular septal defects with respect to the origins of the great arteries is subaortic (type A and type B) in 23 cases, subpulmonary (type C) in 13 cases, doubly committed (type D) in 3 cases, and uncommitted (type E) in 5 cases. 6. Associated cardiac malformations are pulmonary stenosis in 24 which had all cases of type A and type E, aortic stenosis in 6 which were only in type C, left SVC in 6, abnormality of atrioventricular valve in 5, single coronary artery

  15. 3D Printing in Surgical Management of Double Outlet Right Ventricle.

    Science.gov (United States)

    Yoo, Shi-Joon; van Arsdell, Glen S

    2017-01-01

    Double outlet right ventricle (DORV) is a heterogeneous group of congenital heart diseases that require individualized surgical approach based on precise understanding of the complex cardiovascular anatomy. Physical 3-dimensional (3D) print models not only allow fast and unequivocal perception of the complex anatomy but also eliminate misunderstanding or miscommunication among imagers and surgeons. Except for those cases showing well-recognized classic surgical anatomy of DORV such as in cases with a typical subaortic or subpulmonary ventricular septal defect, 3D print models are of enormous value in surgical decision and planning. Furthermore, 3D print models can also be used for rehearsal of the intended procedure before the actual surgery on the patient so that the outcome of the procedure is precisely predicted and the procedure can be optimally tailored for the patient's specific anatomy. 3D print models are invaluable resource for hands-on surgical training of congenital heart surgeons.

  16. 3D Printing in Surgical Management of Double Outlet Right Ventricle

    Directory of Open Access Journals (Sweden)

    Shi-Joon Yoo

    2018-01-01

    Full Text Available Double outlet right ventricle (DORV is a heterogeneous group of congenital heart diseases that require individualized surgical approach based on precise understanding of the complex cardiovascular anatomy. Physical 3-dimensional (3D print models not only allow fast and unequivocal perception of the complex anatomy but also eliminate misunderstanding or miscommunication among imagers and surgeons. Except for those cases showing well-recognized classic surgical anatomy of DORV such as in cases with a typical subaortic or subpulmonary ventricular septal defect, 3D print models are of enormous value in surgical decision and planning. Furthermore, 3D print models can also be used for rehearsal of the intended procedure before the actual surgery on the patient so that the outcome of the procedure is precisely predicted and the procedure can be optimally tailored for the patient’s specific anatomy. 3D print models are invaluable resource for hands-on surgical training of congenital heart surgeons.

  17. Policy coherence, integration, and proportionality in tobacco control: Should tobacco sales be limited to government outlets?

    Science.gov (United States)

    Smith, Elizabeth A; McDaniel, Patricia A; Hiilamo, Heikki; Malone, Ruth E

    2017-08-01

    Multiple factors, including marijuana decriminalization/legalization, tobacco endgame discourse, and alcohol industry pressures, suggest that the retail regulatory environment for psychoactive or addictive substances is a dynamic one in which new options may be considered. In most countries, the regulation of tobacco, marijuana, and alcohol is neither coherent, nor integrated, nor proportional to the potential harms caused by these substances. We review the possible consequences of restricting tobacco sales to outlets run by government-operated alcohol retail monopolies, as well as the likely obstacles to such a policy. Such a move would allow governments more options for regulating tobacco sales, and increase coherence, integration, and proportionality of substance regulation. It might also serve as an incremental step toward an endgame goal of eliminating sales of commercial combustible tobacco.

  18. Three-dimensional stereology as a tool for evaluating bladder outlet obstruction

    DEFF Research Database (Denmark)

    Van Der Wijk, Jasper; Van Der Wijk, Jan; Horn, Thomas

    2008-01-01

    Objective. In a pilot study we evaluated whether implementation of a novel 3D stereologic technique can prove that bladder outlet obstruction (BOO) is associated with morphologic changes in the bladder wall. Material and methods. Ten males (mean age 69.7 years; range 58-84 years) with lower urinary...... tract symptoms (LUTS) suggestive of BOO and five controls (mean age 48.6 years; range 43-53 years) without LUTS were studied. All participants underwent a full examination, including determination of the International Prostate Symptom Score, laboratory analysis and a urodynamic evaluation. A cold....... Conclusions. This pilot study shows that, even with the implementation of subtle morphometric techniques, there seems to be no relationship between the severity of BOO and bladder wall morphology. It is possible that interstitial collagen in the bladder wall increases with age. It seems that bladder wall...

  19. Epidemiology and etiology of benign prostatic hyperplasia and bladder outlet obstruction

    Directory of Open Access Journals (Sweden)

    Nishant D Patel

    2014-01-01

    Full Text Available Benign prostatic hyperplasia (BPH is a histological diagnosis associated with unregulated proliferation of connective tissue, smooth muscle and glandular epithelium. BPH may compress the urethra and result in anatomic bladder outlet obstruction (BOO; BOO may present as lower urinary tract symptoms (LUTS, infections, retention and other adverse events. BPH and BOO have a significant impact on the health of older men and health-care costs. As the world population ages, the incidence and prevalence of BPH and LUTS have increased rapidly. Although non-modifiable risk factors - including age, genetics and geography - play significant roles in the etiology of BPH and BOO, recent data have revealed modifiable risk factors that present new opportunities for treatment and prevention, including sex steroid hormones, the metabolic syndrome and cardiovascular disease, obesity, diabetes, diet, physical activity and inflammation. We review the natural history, definitions and key risk factors of BPH and BOO in epidemiological studies.

  20. Preoperative Duplex Scanning is a Helpful Diagnostic Tool in Neurogenic Thoracic Outlet Syndrome.

    Science.gov (United States)

    Orlando, Megan S; Likes, Kendall C; Mirza, Serene; Cao, Yue; Cohen, Anne; Lum, Ying Wei; Freischlag, Julie A

    2016-01-01

    To evaluate the diagnostic role of venous and arterial duplex scanning in neurogenic thoracic outlet syndrome (NTOS). Retrospective review of patients who underwent duplex ultrasonography prior to first rib resection and scalenectomy (FRRS) for NTOS from 2005 to 2013. Abnormal scans included ipsilateral compression (IC) with abduction of the symptomatic extremity (>50% change in subclavian vessel flow), contralateral (asymptomatic side) compression (CC) or bilateral compression (BC). A total of 143 patients (76% female, average age 34, range 13-59) underwent bilateral preoperative duplex scanning. Ipsilateral compression was seen in 44 (31%), CC in 12 (8%), and BC in 14 (10%). Seventy-three (51%) patients demonstrated no compression. Patients with IC more often experienced intraoperative pneumothoraces (49% vs. 25%, P duplex ultrasonography can assist in NTOS diagnosis. Ipsilateral compression on abduction often correlates with Adson testing. © The Author(s) 2016.