WorldWideScience

Sample records for optimized reference standards

  1. Standard Reference Tables -

    Data.gov (United States)

    Department of Transportation — The Standard Reference Tables (SRT) provide consistent reference data for the various applications that support Flight Standards Service (AFS) business processes and...

  2. Optimal primitive reference frames

    International Nuclear Information System (INIS)

    Jennings, David

    2011-01-01

    We consider the smallest possible directional reference frames allowed and determine the best one can ever do in preserving quantum information in various scenarios. We find that for the preservation of a single spin state, two orthogonal spins are optimal primitive reference frames; and in a product state, they do approximately 22% as well as an infinite-sized classical frame. By adding a small amount of entanglement to the reference frame, this can be raised to 2(2/3) 5 =26%. Under the different criterion of entanglement preservation, a very similar optimal reference frame is found; however, this time it is for spins aligned at an optimal angle of 87 deg. In this case 24% of the negativity is preserved. The classical limit is considered numerically, and indicates under the criterion of entanglement preservation, that 90 deg. is selected out nonmonotonically, with a peak optimal angle of 96.5 deg. for L=3 spins.

  3. ASTM reference radiologic digital image standards

    International Nuclear Information System (INIS)

    Wysnewski, R.; Wysnewski, D.

    1996-01-01

    ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary

  4. An Optimal Control Modification to Model-Reference Adaptive Control for Fast Adaptation

    Science.gov (United States)

    Nguyen, Nhan T.; Krishnakumar, Kalmanje; Boskovic, Jovan

    2008-01-01

    This paper presents a method that can achieve fast adaptation for a class of model-reference adaptive control. It is well-known that standard model-reference adaptive control exhibits high-gain control behaviors when a large adaptive gain is used to achieve fast adaptation in order to reduce tracking error rapidly. High gain control creates high-frequency oscillations that can excite unmodeled dynamics and can lead to instability. The fast adaptation approach is based on the minimization of the squares of the tracking error, which is formulated as an optimal control problem. The necessary condition of optimality is used to derive an adaptive law using the gradient method. This adaptive law is shown to result in uniform boundedness of the tracking error by means of the Lyapunov s direct method. Furthermore, this adaptive law allows a large adaptive gain to be used without causing undesired high-gain control effects. The method is shown to be more robust than standard model-reference adaptive control. Simulations demonstrate the effectiveness of the proposed method.

  5. 15 CFR 230.3 - New Standard Reference Materials.

    Science.gov (United States)

    2010-01-01

    ... NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE STANDARD REFERENCE MATERIALS STANDARD REFERENCE MATERIALS General Information § 230.3 New Standard Reference Materials. When new SRM's... scientific and trade journals. ...

  6. Ozone Standard Reference Photometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Standard Reference Photometer (SRP) Program began in the early 1980s as collaboration between NIST and the U.S. Environmental Protection Agency (EPA) to design,...

  7. From plastic to gold: a unified classification scheme for reference standards in medical image processing

    Science.gov (United States)

    Lehmann, Thomas M.

    2002-05-01

    Reliable evaluation of medical image processing is of major importance for routine applications. Nonetheless, evaluation is often omitted or methodically defective when novel approaches or algorithms are introduced. Adopted from medical diagnosis, we define the following criteria to classify reference standards: 1. Reliance, if the generation or capturing of test images for evaluation follows an exactly determined and reproducible protocol. 2. Equivalence, if the image material or relationships considered within an algorithmic reference standard equal real-life data with respect to structure, noise, or other parameters of importance. 3. Independence, if any reference standard relies on a different procedure than that to be evaluated, or on other images or image modalities than that used routinely. This criterion bans the simultaneous use of one image for both, training and test phase. 4. Relevance, if the algorithm to be evaluated is self-reproducible. If random parameters or optimization strategies are applied, reliability of the algorithm must be shown before the reference standard is applied for evaluation. 5. Significance, if the number of reference standard images that are used for evaluation is sufficient large to enable statistically founded analysis. We demand that a true gold standard must satisfy the Criteria 1 to 3. Any standard only satisfying two criteria, i.e., Criterion 1 and Criterion 2 or Criterion 1 and Criterion 3, is referred to as silver standard. Other standards are termed to be from plastic. Before exhaustive evaluation based on gold or silver standards is performed, its relevance must be shown (Criterion 4) and sufficient tests must be carried out to found statistical analysis (Criterion 5). In this paper, examples are given for each class of reference standards.

  8. Development of standard reference samples for diffractometry

    International Nuclear Information System (INIS)

    Galvao, Antonio de Sant'Ana

    2011-01-01

    In this work, samples of standard reference materials for diffractometry of polycrystals were developed. High-purity materials were submitted to mechanical and thermal treatments in order to present the adequate properties to be used as high-quality standard reference materials for powder diffraction, comparable to the internationally recognized produced by the USA National Institute of Standards and Technology NIST, but at lower costs. The characterization of the standard materials was performed by measurements in conventional X-ray diffraction diffractometers, high resolution neutron diffraction and high-resolution synchrotron diffraction. The lattice parameters were calculated by extrapolation of the values obtained from each X-ray reflection against cos 2 θ by the Least-Squares Method. The adjustments were compared to the values obtained by the Rietveld Method, using program GSAS. The materials thus obtained were the α-alumina, yttrium oxide, silicon, cerium oxide, lanthanum hexaboride and lithium fluoride. The standard reference materials produced present quality similar or, in some cases, superior to the standard reference materials produced and commercialized by the NIST. (author)

  9. Standard digital reference images for titanium castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in titanium castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images, which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of titanium casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 The digital reference images consist of seventeen digital files each illustrating eight grades of increasing severity. The files illustrate seven common discontinuity types representing casting sections up to 1-in. (25.4-mm). 1.3 The reference radiographs were developed for casting sections up to 1...

  10. Reference-shaping adaptive control by using gradient descent optimizers.

    Directory of Open Access Journals (Sweden)

    Baris Baykant Alagoz

    Full Text Available This study presents a model reference adaptive control scheme based on reference-shaping approach. The proposed adaptive control structure includes two optimizer processes that perform gradient descent optimization. The first process is the control optimizer that generates appropriate control signal for tracking of the controlled system output to a reference model output. The second process is the adaptation optimizer that performs for estimation of a time-varying adaptation gain, and it contributes to improvement of control signal generation. Numerical update equations derived for adaptation gain and control signal perform gradient descent optimization in order to decrease the model mismatch errors. To reduce noise sensitivity of the system, a dead zone rule is applied to the adaptation process. Simulation examples show the performance of the proposed Reference-Shaping Adaptive Control (RSAC method for several test scenarios. An experimental study demonstrates application of method for rotor control.

  11. Threshold-driven optimization for reference-based auto-planning

    Science.gov (United States)

    Long, Troy; Chen, Mingli; Jiang, Steve; Lu, Weiguo

    2018-02-01

    We study threshold-driven optimization methodology for automatically generating a treatment plan that is motivated by a reference DVH for IMRT treatment planning. We present a framework for threshold-driven optimization for reference-based auto-planning (TORA). Commonly used voxel-based quadratic penalties have two components for penalizing under- and over-dosing of voxels: a reference dose threshold and associated penalty weight. Conventional manual- and auto-planning using such a function involves iteratively updating the preference weights while keeping the thresholds constant, an unintuitive and often inconsistent method for planning toward some reference DVH. However, driving a dose distribution by threshold values instead of preference weights can achieve similar plans with less computational effort. The proposed methodology spatially assigns reference DVH information to threshold values, and iteratively improves the quality of that assignment. The methodology effectively handles both sub-optimal and infeasible DVHs. TORA was applied to a prostate case and a liver case as a proof-of-concept. Reference DVHs were generated using a conventional voxel-based objective, then altered to be either infeasible or easy-to-achieve. TORA was able to closely recreate reference DVHs in 5-15 iterations of solving a simple convex sub-problem. TORA has the potential to be effective for auto-planning based on reference DVHs. As dose prediction and knowledge-based planning becomes more prevalent in the clinical setting, incorporating such data into the treatment planning model in a clear, efficient way will be crucial for automated planning. A threshold-focused objective tuning should be explored over conventional methods of updating preference weights for DVH-guided treatment planning.

  12. Anthropometry as a tool for measuring malnutrition: impact of the new WHO growth standards and reference.

    Science.gov (United States)

    Duggan, M B

    2010-01-01

    Anthropometry is a useful tool, both for monitoring growth and for nutritional assessment. The publication by WHO of internationally agreed growth standards in 1983 facilitated comparative nutritional assessment and the grading of childhood malnutrition. New growth standards for children under 5 years and growth reference for children aged 5-19 years have recently (2006 and 2007) been published by WHO. Growth of children growth reference study involving children from six countries, selected for optimal child-rearing practices (breastfeeding, non-smoking mothers). They therefore constitute a growth standard. Growth data for older children were drawn from existing US studies, and upward skewing was avoided by excluding overweight subjects. These constitute a reference. More indicators are now included to describe optimal early childhood growth and development, e.g. BMI for age and MUAC for age. The growth reference for older children (2007) focuses on linear growth and BMI; weight-for-age data are age-limited and weight-for-height is omitted. Differences in the 2006 growth pattern from the previous reference for children toddler. The spread of values for height and weight for height is narrower in the 2006 dataset, such that the lower limit of the normal range for both indices is set higher than in the previous dataset. This means that a child will be identified as moderately or severely underweight for height (severe acute malnutrition) at a greater weight for height than previously. The implications for services for malnourished children have been recognised and strategies devised. The emphasis on BMI-for-age as the indicator for thinness and obesity in older children is discussed. The complexity of calculations for health cadres without mathematical backgrounds or access to calculation software is also an issue. It is possible that the required charts and tables may not be accessible to those working in traditional health/nutrition services which are often poorly

  13. Fabricating defensible reference standards for the NDA lab

    Energy Technology Data Exchange (ETDEWEB)

    Ceo, R.N.; May, P.K. [Oak Ridge Y-12 Plant, TN (United States)

    1997-11-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs.

  14. Fabricating defensible reference standards for the NDA lab

    International Nuclear Information System (INIS)

    Ceo, R.N.; May, P.K.

    1997-01-01

    Nondestructive analysis (NDA) is performed at the Oak Ridge Y-12 Plant in support of the enriched uranium operations. Process materials are analyzed using gamma ray- and neutron-based instruments including segmented gamma scanners, solution assay systems, and an active well coincidence counter. Process wastes are also discarded based on results of these measurements. Good analytical practice, as well as applicable regulations, mandates that these analytical methods be calibrated using reference materials traceable to the national standards base. Reference standards for NDA instruments are not commercially available owing to the large quantities of special nuclear materials involved. Instead, representative materials are selected from each process stream, then thoroughly characterized by methods that are traceable to the national standards base. This paper discusses the process materials to be analyzed, reference materials selected for calibrating each NDA instrument, and details of their characterization and fabrication into working calibrations standards. Example calibration curves are also presented. 4 figs

  15. Standard Reference Development of nuclear material for Tensile and Hardness Test Properties

    International Nuclear Information System (INIS)

    Choo, Y. S.; Kim, D. S.; Yoo, B. O.; Ahn, S. B.; Baik, S. J.; Chun, Y. B.; Kim, K. H.; Hong, K. P.; Ryu, W. S.

    2007-12-01

    Standard reference is a official approved data such a coefficient of physics, approved material properties, and etc., which should be analyzed and evaluated by scientific method to acquire official approval for accuracy and credibility of measured data and information. So it could be used broadly and continuously by various fields of nation and society. It is classified to effective standard reference, verified standard reference, and certified standard reference. There are sixteen fields in designated standard references such a physical chemistry field, material field, metal field, and the others. The standard reference of neutron irradiated nuclear structural material is classified to metal field. This report summarized the whole processes about data collection, data production, data evaluation and the suggestion of details evaluation technical standard for tensile and hardness properties, which were achieved by carry out the project 'nuclear material standard reference development' as a result

  16. Standard Reference Development of nuclear material for Tensile and Hardness Test Properties

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Y. S.; Kim, D. S.; Yoo, B. O.; Ahn, S. B.; Baik, S. J.; Chun, Y. B.; Kim, K. H.; Hong, K. P.; Ryu, W. S

    2007-12-15

    Standard reference is a official approved data such a coefficient of physics, approved material properties, and etc., which should be analyzed and evaluated by scientific method to acquire official approval for accuracy and credibility of measured data and information. So it could be used broadly and continuously by various fields of nation and society. It is classified to effective standard reference, verified standard reference, and certified standard reference. There are sixteen fields in designated standard references such a physical chemistry field, material field, metal field, and the others. The standard reference of neutron irradiated nuclear structural material is classified to metal field. This report summarized the whole processes about data collection, data production, data evaluation and the suggestion of details evaluation technical standard for tensile and hardness properties, which were achieved by carry out the project 'nuclear material standard reference development' as a result.

  17. Standard digital reference images for inspection of aluminum castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These digital reference images illustrate the types and degrees of discontinuities that may be found in aluminum-alloy castings. The castings illustrated are in thicknesses of 1/ 4 in. [6.35 mm] and 3/4 in. [19.1mm]. 1.2 All areas of this standard may be open to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract. 1.3 The values stated in inch-pound units are to be regarded as standard. 1.4 These digital reference images are not intended to illustrate the types and degrees of discontinuities found in aluminum-alloy castings when performing film radiography. If performing film radiography of aluminum-alloy castings, refer to Reference Radiographs E 155. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and he...

  18. Bibliographic Citations With Special Reference Indian Bibliographic Standard

    Directory of Open Access Journals (Sweden)

    Reshmi Sarkar

    2015-08-01

    Full Text Available Bibliographic citation is playing an important role today to ensure the completeness of all research activities. They occupy an integral part as a reference in all types of resources need. The author while writing a paper takes the references from a number of documents and finally quotes them with its bibliographic details to recognize the work of earlier authors in the same field of study. With the virtually exponential growth in the research literatures throughout the 20th century it has become clear that the larger the literature the more difficult are the problems caused by poorly crafted bibliographic references. Scholarly societies like publishers of research journals have either produced their own or have endorsed common bibliographic style manuals or standards. In this study we have studied several style manuals and standards for bibliographic referencing and several editorial guidelines for this purpose to compare them. Indian bibliographic standard gets special attention.

  19. 15 CFR 200.105 - Standard reference data.

    Science.gov (United States)

    2010-01-01

    ... for application in energy, environment and health, industrial process design, materials durability... application in research, development, engineering design, and commerce. The Office of Standard Reference Data...

  20. Practical reference - radiation standards in Canada

    International Nuclear Information System (INIS)

    1983-07-01

    In developing a policy that will require licensees to calibrate their radiation dose measuring devices and trace such calibrations to approved reference standards, the AECB has consulted recognized experts. This document presents the experts' reports and recommendations which will be considered in finalizing the policy

  1. Thermal-Diffusivity-Based Frequency References in Standard CMOS

    NARCIS (Netherlands)

    Kashmiri, S.M.

    2012-01-01

    In recent years, a lot of research has been devoted to the realization of accurate integrated frequency references. A thermal-diffusivity-based (TD) frequency reference provides an alternative method of on-chip frequency generation in standard CMOS technology. A frequency-locked loop locks the

  2. Hg0 and HgCl2 Reference Gas Standards: ?NIST Traceability ...

    Science.gov (United States)

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the true concentrations of Hg0 and HgCl2 reference gases produced from high quality, NIST-traceable, commercial Hg0 and HgCl2 generators. This presentation will also discuss the availability of HCl and Hg0 compressed reference gas standards as a result of EPA's recently approved Alternative Methods 114 and 118. Gaseous elemental mercury (Hg0) and oxidized mercury (HgCl2) reference standards are integral to the use of mercury continuous emissions monitoring systems (Hg CEMS) for regulatory compliance emissions monitoring. However, a quantitative disparity of approximately 7-10% has been observed between commercial Hg0 and HgCl2 reference gases which currently limits the use of (HgCl2) reference gas standards. Resolving this disparity would enable the expanded use of (HgCl2) reference gas standards for regulatory compliance purposes.

  3. A comparative uncertainty study of the calibration of macrolide antibiotic reference standards using quantitative nuclear magnetic resonance and mass balance methods

    International Nuclear Information System (INIS)

    Liu Shuyu; Hu Changqin

    2007-01-01

    This study introduces the general method of quantitative nuclear magnetic resonance (qNMR) for the calibration of reference standards of macrolide antibiotics. Several qNMR experimental conditions were optimized including delay, which is an important parameter of quantification. Three kinds of macrolide antibiotics were used to validate the accuracy of the qNMR method by comparison with the results obtained by the high performance liquid chromatography (HPLC) method. The purities of five common reference standards of macrolide antibiotics were measured by the 1 H qNMR method and the mass balance method, respectively. The analysis results of the two methods were compared. The qNMR is quick and simple to use. In a new medicine research and development process, qNMR provides a new and reliable method for purity analysis of the reference standard

  4. Characterization of standard reference material 2944, Bi-ion-doped glass, spectral correction standard for red fluorescence

    International Nuclear Information System (INIS)

    DeRose, Paul C.; Smith, Melody V.; Anderson, Jeffrey R.; Kramer, Gary W.

    2013-01-01

    Standard Reference Material (SRM) 2944 is a cuvette-shaped, Bi-ion-doped glass, recommended for optimal use for relative spectral correction of emission from 590 nm to 805 nm and day-to-day performance verification of steady-state fluorescence spectrometers. Properties of this standard that influence its effective use or contribute to the uncertainty in its certified emission spectrum were explored here. These properties include its photostability, absorbance, dissolution rate in water, anisotropy and temperature coefficient of fluorescence intensity. The expanded uncertainties (k=2) in the certified spectrum are about 4% around the nominal peak maximum at 704 nm and increase to about 6% at the wings, using an excitation wavelength of 515 nm. -- Highlights: ► The fluorescence emission spectrum of SRM 2944 was determined for spectral correction. ► This Bi-ion-doped glass has been certified in the fluorescence region from 530 nm to 830 nm. ► Fluorescence properties of the glass were determined, e.g., anisotropy, lifetime. ► SRM 2944 is photostable under common visible lamp excitation, when UV light is not present

  5. Implementation of a reference standard and proficiency testing programme by the World Wide Antimalarial Resistance Network (WWARN

    Directory of Open Access Journals (Sweden)

    Barnes Karen I

    2010-12-01

    Full Text Available Abstract Background The Worldwide Antimalarial Resistance Network (WWARN is a global collaboration to support the objective that anyone affected by malaria receives effective and safe drug treatment. The Pharmacology module aims to inform optimal anti-malarial drug selection. There is an urgent need to define the drug exposure - effect relationship for most anti-malarial drugs. Few anti-malarials have had their therapeutic blood concentration levels defined. One of the main challenges in assessing safety and efficacy data in relation to drug concentrations is the comparability of data generated from different laboratories. To explain differences in anti-malarial pharmacokinetics in studies with different measurement laboratories it is necessary to confirm the accuracy of the assay methods. This requires the establishment of an external quality assurance process to assure results that can be compared. This paper describes this process. Methods The pharmacology module of WWARN has established a quality assurance/quality control (QA/QC programme consisting of two separate components: 1. A proficiency testing programme where blank human plasma spiked with certified reference material (CRM in different concentrations is sent out to participating bioanalytical laboratories. 2. A certified reference standard programme where accurately weighed amounts of certified anti-malarial reference standards, metabolites, and internal standards are sent to participating bioanalytical and in vitro laboratories. Conclusion The proficiency testing programme is designed as a cooperative effort to help participating laboratories assess their ability to carry out drug analysis, resolve any potential problem areas and to improve their results - and, in so doing, to improve the quality of anti-malarial pharmacokinetic data published and shared with WWARN. By utilizing the same source of standards for all laboratories, it is possible to minimize bias arising from poor

  6. Reference Tracking and Profit Optimization of a Power Plant

    DEFF Research Database (Denmark)

    Kragelund, Martin Nygaard; Leth, John-Josef; Wisniewski, Rafal

    2010-01-01

    In this paper we discuss two different methods for implementing reference tracking intro a profit optimization problem of a power plant. It is shown that tracking included as a side constraint results in an significant tracking error only when the reference gradient is large. When tracking...... is included in the cost function, as a quadratic term, the reference is tracked with a small accumulated error. Finally, the two methods are compared both in terms of tracking performance and computational burden....

  7. Semi-automatic construction of reference standards for evaluation of image registration

    NARCIS (Netherlands)

    Murphy, K.; Ginneken, van B.; Klein, S.; Staring, M.; Hoop, de B.J.; Viergever, M.A.; Pluim, J.P.W.

    2011-01-01

    Quantitative evaluation of image registration algorithms is a difficult and under-addressed issue due to the lack of a reference standard in most registration problems. In this work a method is presented whereby detailed reference standard data may be constructed in an efficient semi-automatic

  8. Optimization and standardization of pavement management processes.

    Science.gov (United States)

    2004-08-01

    This report addresses issues related to optimization and standardization of current pavement management processes in Kentucky. Historical pavement management records were analyzed, which indicates that standardization is necessary in future pavement ...

  9. Generation of gaseous methanol reference standards

    International Nuclear Information System (INIS)

    Geib, R.C.

    1991-01-01

    Methanol has been proposed as an automotive fuel component. Reliable, accurate methanol standards are essential to support widespread monitoring programs. The monitoring programs may include quantification of methanol from tailpipe emissions, evaporative emissions, plus ambient air methanol measurements. This paper will present approaches and results in the author's investigation to develop high accuracy methanol standards. The variables upon which the authors will report results are as follows: (1) stability of methanol gas standards, the studies will focus on preparation requirements and stability results from 10 to 1,000 ppmv; (2) cylinder to instrument delivery system components and purge technique, these studies have dealt with materials in contact with the sample stream plus static versus flow injection; (3) optimization of gas chromatographic analytical system will be discussed; (4) gas chromatography and process analyzer results and utility for methanol analysis will be presented; (5) the accuracy of the methanol standards will be qualified using data from multiple studies including: (a) gravimetric preparation; (b) linearity studies; (c) independent standards sources such as low pressure containers and diffusion tubes. The accuracy will be provided as a propagation of error from multiple sources. The methanol target concentrations will be 10 to 500 ppmv

  10. ENAA of iodine in standard reference material lyophilized human urine

    International Nuclear Information System (INIS)

    Zhang Yongbao; Wang Ke; Wang Ganfeng

    1997-01-01

    The contents of iodine in two kinds of standard reference materials lyophilized human urine are determined by ENAA. The sensitivity of this method is ten times higher than that of TNAA, and the relative standard deviations of ten measurements are 2.9% and 3.3%, respectively. Two certificated reference samples are used for verification of the analysis. The analytical results are in agreement with the recommended values, and the relative error is less than 3%

  11. [Application of traditional Chinese medicine reference standards in quality control of Chinese herbal pieces].

    Science.gov (United States)

    Lu, Tu-Lin; Li, Jin-Ci; Yu, Jiang-Yong; Cai, Bao-Chang; Mao, Chun-Qin; Yin, Fang-Zhou

    2014-01-01

    Traditional Chinese medicine (TCM) reference standards plays an important role in the quality control of Chinese herbal pieces. This paper overviewed the development of TCM reference standards. By analyzing the 2010 edition of Chinese pharmacopoeia, the application of TCM reference standards in the quality control of Chinese herbal pieces was summarized, and the problems exiting in the system were put forward. In the process of improving the quality control level of Chinese herbal pieces, various kinds of advanced methods and technology should be used to research the characteristic reference standards of Chinese herbal pieces, more and more reasonable reference standards should be introduced in the quality control system of Chinese herbal pieces. This article discussed the solutions in the aspect of TCM reference standards, and future development of quality control on Chinese herbal pieces is prospected.

  12. Determination of trace elements in standard reference materials by the ko-standardization method

    International Nuclear Information System (INIS)

    Smodis, B.; Jacimovic, R.; Stegnar, P.; Jovanovic, S.

    1990-01-01

    The k o -standardization method is suitable for routine multielement determinations by reactor neutron activation analysis (NAA). Investigation of NIST standard reference materials SRM 1571 Orchard Leaves, SRM 1572 Citrus leaves, and SRM 1573 Tomato Leaves showed the systematic error of 12 certified elements determined to be less than 8%. Thirty-four elements were determined in NIST proposed SRM 1515 Apple Leaves

  13. 78 FR 13243 - Updates to Standards Incorporated by Reference; Reapproved ASTM Standards; Technical Amendment

    Science.gov (United States)

    2013-02-27

    ... Characteristics of Plastic Film 2009)[egr]1. and Sheeting. Standard Specification for F682-82a F682-82a 46 56.01-2... (Reapproved Standard Test Method for Determining Gas 2009)[egr]1. Permeability Characteristics of Plastic Film... Permeability Characteristics of Plastic Film and Sheeting (approved May 1, 2009), incorporation by reference...

  14. The cost of model reference adaptive control - Analysis, experiments, and optimization

    Science.gov (United States)

    Messer, R. S.; Haftka, R. T.; Cudney, H. H.

    1993-01-01

    In this paper the performance of Model Reference Adaptive Control (MRAC) is studied in numerical simulations and verified experimentally with the objective of understanding how differences between the plant and the reference model affect the control effort. MRAC is applied analytically and experimentally to a single degree of freedom system and analytically to a MIMO system with controlled differences between the model and the plant. It is shown that the control effort is sensitive to differences between the plant and the reference model. The effects of increased damping in the reference model are considered, and it is shown that requiring the controller to provide increased damping actually decreases the required control effort when differences between the plant and reference model exist. This result is useful because one of the first attempts to counteract the increased control effort due to differences between the plant and reference model might be to require less damping, however, this would actually increase the control effort. Optimization of weighting matrices is shown to help reduce the increase in required control effort. However, it was found that eventually the optimization resulted in a design that required an extremely high sampling rate for successful realization.

  15. Halogens determination in vegetable NBS standard reference materials

    International Nuclear Information System (INIS)

    Stella, R.; Genova, N.; Di Casa, M.

    1977-01-01

    Levels of all four halogens in Orchard Leaves, Pine Needles and Tomato Leaves NBS reference standards were determined. For fluorine a spiking isotope dilution method was used followed by HF absorption on glass beads. Instrumental nuclear activation analysis was adopted for chlorine and bromine determination. Radiochemical separation by a distillation procedure was necessary for iodine nuclear activation analysis after irradiation. Activation parameters of Cl, Br and I are reported. Results of five determinations for each halogen in Orchard Leaves, Pine Needles and Tomato Leaves NBS Standard Materials and Standard deviations of the mean are reported. (T.I.)

  16. 28 CFR 45.1 - Cross-reference to ethical standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Cross-reference to ethical standards and...) EMPLOYEE RESPONSIBILITIES § 45.1 Cross-reference to ethical standards and financial disclosure regulations. Employees of the Department of Justice are subject to the executive branch-wide Standards of Ethical Conduct...

  17. On criteria for examining analysis quality with standard reference material

    International Nuclear Information System (INIS)

    Yang Huating

    1997-01-01

    The advantages and disadvantages and applicability of some criteria for examining analysis quality with standard reference material are discussed. The combination of the uncertainties of the instrument examined and the reference material should be determined on the basis of specific situations. Without the data of the instrument's uncertainty, it would be applicable to substitute the standard deviation multiplied by certain times for the uncertainty. The result of the examining should not result in more error reported in routine measurements than it really is. Over strict examining should also be avoided

  18. Comparison Between a Reference Torque Standard Machine and a Deadweight Torque Standard Machine to BE Used in Torque Calibration

    Science.gov (United States)

    Meng, Feng; Zhang, Zhimin; Lin, Jing

    The paper describes the reference torque standard machine with high accuracy and multifunction, developed by our institute, and introduces the structure and working principle of this machine. It has three main functions. The first function is the hydraulic torque wrench calibration function. The second function is torque multiply calibration function. The third function is reference torque standard machine function. We can calibrate the torque multipliers, hydraulic wrenches and transducers by this machine. A comparison experiment has been done between this machine and a deadweight torque standard machine. The consistency between the 30 kNm reference torque machine and the 2000 Nm dead-weight torque standard machine under the claimed uncertainties was verified.

  19. Determination of polybrominated diphenyl ethers in environmental standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, Heather M.; Schantz, Michele M.; Wise, Stephen A. [National Institute of Standards and Technology, Analytical Chemistry Division, Gaithersburg, MD (United States); Keller, Jennifer M.; Kucklick, John R. [National Institute of Standards and Technology, Analytical Chemistry Division, Hollings Marine Laboratory, Charleston, SC (United States); Leigh, Stefan D. [National Institute of Standards and Technology, Statistical Engineering Division, Gaithersburg, MD (United States)

    2007-04-15

    Standard reference materials (SRMs) are valuable tools in developing and validating analytical methods to improve quality assurance standards. The National Institute of Standards and Technology (NIST) has a long history of providing environmental SRMs with certified concentrations of organic and inorganic contaminants. Here we report on new certified and reference concentrations for 27 polybrominated diphenyl ether (PBDE) congeners in seven different SRMs: cod-liver oil, whale blubber, fish tissue (two materials), mussel tissue and sediment (two materials). PBDEs were measured in these SRMs, with the lowest concentrations measured in mussel tissue (SRM 1974b) and the highest in sediment collected from the New York/New Jersey Waterway (SRM 1944). Comparing the relative PBDE congener concentrations within the samples, we found the biota SRMs contained primarily tetrabrominated and pentabrominated diphenyl ethers, whereas the sediment SRMs contained primarily decabromodiphenyl ether (BDE 209). The cod-liver oil (SRM 1588b) and whale blubber (SRM 1945) materials were also found to contain measurable concentrations of two methoxylated PBDEs (MeO-BDEs). Certified and reference concentrations are reported for 12 PBDE congeners measured in the biota SRMs and reference values are available for two MeO-BDEs. Results from a sediment interlaboratory comparison PBDE exercise are available for the two sediment SRMs (1941b and 1944). (orig.)

  20. A reference standard-based quality assurance program for radiology.

    Science.gov (United States)

    Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J

    2010-01-01

    The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. 76 FR 8989 - Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References

    Science.gov (United States)

    2011-02-16

    ... Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References AGENCIES... Acquisition Regulation (FAR) to update references to authoritative accounting standards owing to the Financial... Accounting Principles (GAAP) (``Codification of GAAP''). DATES: Interested parties should submit written...

  2. Standard digital reference images for investment steel castings for aerospace applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in thin-wall steel investment castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of thin-wall steel casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 Two illustration categories are covered as follows: 1.2.1 Graded—Six common discontinuity types each illustrated in eight degrees of progressively increasing severity. 1.2.2 Ungraded—Twelve single illustrations of additional discontinuity types and of patterns and imper...

  3. New reference trajectory optimization algorithm for a flight management system inspired in beam search

    Directory of Open Access Journals (Sweden)

    Alejandro MURRIETA-MENDOZA

    2017-08-01

    Full Text Available With the objective of reducing the flight cost and the amount of polluting emissions released in the atmosphere, a new optimization algorithm considering the climb, cruise and descent phases is presented for the reference vertical flight trajectory. The selection of the reference vertical navigation speeds and altitudes was solved as a discrete combinatory problem by means of a graph-tree passing through nodes using the beam search optimization technique. To achieve a compromise between the execution time and the algorithm’s ability to find the global optimal solution, a heuristic methodology introducing a parameter called “optimism coefficient was used in order to estimate the trajectory’s flight cost at every node. The optimal trajectory cost obtained with the developed algorithm was compared with the cost of the optimal trajectory provided by a commercial flight management system(FMS. The global optimal solution was validated against an exhaustive search algorithm(ESA, other than the proposed algorithm. The developed algorithm takes into account weather effects, step climbs during cruise and air traffic management constraints such as constant altitude segments, constant cruise Mach, and a pre-defined reference lateral navigation route. The aircraft fuel burn was computed using a numerical performance model which was created and validated using flight test experimental data.

  4. Newly developed standard reference materials for organic contaminant analysis

    Energy Technology Data Exchange (ETDEWEB)

    Poster, D.; Kucklick, J.; Schantz, M.; Porter, B.; Wise, S. [National Inst. of Stand. and Technol., Gaithersburg, MD (USA). Center for Anal. Chem.

    2004-09-15

    The National Institute of Standards and Technology (NIST) has issued a number of Standard Reference Materials (SRM) for specified analytes. The SRMs are biota and biological related materials, sediments and particle related SRMs. The certified compounds for analysis are polychlorinated biphenyls (PCB), polycylic aromatic hydrocarbons (PAH) and their nitro-analogues, chlorinated pesticides, methylmercury, organic tin compounds, fatty acids, polybrominated biphenyl ethers (PBDE). The authors report on origin of materials and analytic methods. (uke)

  5. Electrothermal frequency references in standard CMOS

    CERN Document Server

    Kashmiri, S Mahdi

    2013-01-01

    This book describes an alternative method of accurate on-chip frequency generation in standard CMOS IC processes. This method exploits the thermal-diffusivity of silicon, the rate at which heat diffuses through a silicon substrate.  This is the first book describing thermal-diffusivity-based frequency references, including the complete theoretical methodology supported by practical realizations that prove the feasibility of the method.  Coverage also includes several circuit and system-level solutions for the analog electronic circuit design challenges faced.   ·         Surveys the state-of-the-art in all-silicon frequency references; ·         Examines the thermal properties of silicon as a solution for the challenge of on-chip accurate frequency generation; ·         Uses simplified modeling approaches that allow an electronics engineer easily to simulate the electrothermal elements; ·         Follows a top-down methodology in circuit design, in which system-level des...

  6. 34 CFR 73.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards... of Education STANDARDS OF CONDUCT § 73.1 Cross-reference to employee ethical conduct standards and... branch-wide Standards of Ethical Conduct at 5 CFR part 2635 and to the Department of Education regulation...

  7. Characterization of reference standards for dirt by Laser Ablation Induced Photoacoustics (LAIP)

    International Nuclear Information System (INIS)

    Orzi, D J O; Bilmes, G M; Morel, E N; Torga, J R; Roviglione, A N

    2010-01-01

    Measurements of surface cleanliness and dirt characterization are important problems in a wide range of processes in industry and production. Standard methods are in most cases cumbersome laboratory procedures that must be performed out of the production lines. Instruments and methods for cleanliness determination and dirt characterization require reference standards for calibration. For that purpose we built a possible dirt reference standard (DRS) made by films of graphite grease subjected to heat treatment for mechanical stabilization. The DRS characterization was performed by Laser Ablation Induced Photoacoustics (LAIP). The measurement of the thickness of the films was made by low-coherence interferometry.

  8. 45 CFR 680.10 - Definitions; cross-references to employee ethical conduct standards and financial disclosure...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Definitions; cross-references to employee ethical... Foundation § 680.10 Definitions; cross-references to employee ethical conduct standards and financial...-references to employee ethical conduct standards and financial disclosure regulations. Members of the...

  9. 49 CFR 1019.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Cross-reference to employee ethical conduct... Cross-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees of the Surface Transportation Board also should refer to the executive branch Standards of Ethical...

  10. Consensus values for NIST biological and environmental Standard Reference Materials

    International Nuclear Information System (INIS)

    Roelandts, I.; Gladney, E.S.

    1998-01-01

    The National Institute of Standards and Technology (NIST, formerly the National Bureau of Standards or NBS) has produced numerous Standard Reference Materials (SRM) for use in biological and environmental analytical chemistry. The value listed on the ''NIST Certificate of Analysis'' is the present best estimate of the ''true'' concentration of that element and is not expected to deviate from that concentration by more than the stated uncertainty. However, NIST does not certify the elemental concentration of every constituent and the number of elements reported in the NIST programs tends to be limited.Numerous analysts have published concentration data on these reference materials. Major journals in analytical chemistry, books, proceedings and ''technical reports'' have been surveyed to collect these available literature values. A standard statistical approach has been employed to evaluate the compiled data. Our methodology has been developed in a series of previous papers. Some subjective criteria are first used to reject aberrant data. Following these eliminations, an initial arithmetic mean and standard deviation (S.D.) are computed from remaining data for each element. All data now outside two S.D. from the initial mean are dropped and a second mean and S.D. recalculated. These final means and associated S.D. are reported as ''consensus values'' in our tables. (orig.)

  11. Positive animal welfare states and reference standards for welfare assessment.

    Science.gov (United States)

    Mellor, D J

    2015-01-01

    Developments in affective neuroscience and behavioural science during the last 10-15 years have together made it increasingly apparent that sentient animals are potentially much more sensitive to their environmental and social circumstances than was previously thought to be the case. It therefore seems likely that both the range and magnitude of welfare trade-offs that occur when animals are managed for human purposes have been underestimated even when minimalistic but arguably well-intentioned attempts have been made to maintain high levels of welfare. In light of these neuroscience-supported behaviour-based insights, the present review considers the extent to which the use of currently available reference standards might draw attention to these previously neglected areas of concern. It is concluded that the natural living orientation cannot provide an all-embracing or definitive welfare benchmark because of its primary focus on behavioural freedom. However assessments of this type, supported by neuroscience insights into behavioural motivation, may now carry greater weight when used to identify management practices that should be avoided, discontinued or substantially modified. Using currently accepted baseline standards as welfare reference points may result in small changes being accorded greater significance than would be the case if they were compared with higher standards, and this could slow the progress towards better levels of welfare. On the other hand, using "what animals want" as a reference standard has the appeal of focusing on the specific resources or conditions the animals would choose themselves and can potentially improve their welfare more quickly than the approach of making small increments above baseline standards. It is concluded that the cautious use of these approaches in different combinations could lead to recommendations that would more effectively promote positive welfare states in hitherto neglected areas of concern.

  12. Optimization of reference library used in content-based medical image retrieval scheme

    International Nuclear Information System (INIS)

    Park, Sang Cheol; Sukthankar, Rahul; Mummert, Lily; Satyanarayanan, Mahadev; Zheng Bin

    2007-01-01

    Building an optimal image reference library is a critical step in developing the interactive computer-aided detection and diagnosis (I-CAD) systems of medical images using content-based image retrieval (CBIR) schemes. In this study, the authors conducted two experiments to investigate (1) the relationship between I-CAD performance and size of reference library and (2) a new reference selection strategy to optimize the library and improve I-CAD performance. The authors assembled a reference library that includes 3153 regions of interest (ROI) depicting either malignant masses (1592) or CAD-cued false-positive regions (1561) and an independent testing data set including 200 masses and 200 false-positive regions. A CBIR scheme using a distance-weighted K-nearest neighbor algorithm is applied to retrieve references that are considered similar to the testing sample from the library. The area under receiver operating characteristic curve (A z ) is used as an index to evaluate the I-CAD performance. In the first experiment, the authors systematically increased reference library size and tested I-CAD performance. The result indicates that scheme performance improves initially from A z =0.715 to 0.874 and then plateaus when the library size reaches approximately half of its maximum capacity. In the second experiment, based on the hypothesis that a ROI should be removed if it performs poorly compared to a group of similar ROIs in a large and diverse reference library, the authors applied a new strategy to identify 'poorly effective' references. By removing 174 identified ROIs from the reference library, I-CAD performance significantly increases to A z =0.914 (p<0.01). The study demonstrates that increasing reference library size and removing poorly effective references can significantly improve I-CAD performance

  13. Characterization of the NIST shellfish Standard Reference Material 4358

    International Nuclear Information System (INIS)

    Nour, S.; Inn, K.G.W.; Filliben, J.; Gaast van der, H.; Men, L.C.; Calmet, D.; Altzitzoglou, T.; Povinec, P.; Takata, Y.; Wisdom, M.

    2013-01-01

    A new shellfish Standard Reference Material 4358 was developed by the National Institute of Standards and Technology through an international interlaboratory comparison that involved twelve laboratories-participants from nine countries. The results from the participants were statistically evaluated, and the most robust certified values were based on the median of laboratories’ reported means and the uncertainties derived using the bootstrap method. Massic activity certified values were established for fourteen radionuclides, five activity ratios, and informational massic activity values for eight more radionuclides and two activity ratios. (author)

  14. Standardization and optimization of arthropod inventories-the case of Iberian spiders

    DEFF Research Database (Denmark)

    Bondoso Cardoso, Pedro Miguel

    2009-01-01

    and optimization of sampling protocols, especially for mega-diverse arthropod taxa. This study had two objectives: (1) propose guidelines and statistical methods to improve the standardization and optimization of arthropod inventories, and (2) to propose a standardized and optimized protocol for Iberian spiders......, by finding common results between the optimal options for the different sites. The steps listed were successfully followed in the determination of a sampling protocol for Iberian spiders. A protocol with three sub-protocols of varying degrees of effort (24, 96 and 320 h of sampling) is proposed. I also...

  15. A new large-volume metal reference standard for radioactive waste management.

    Science.gov (United States)

    Tzika, F; Hult, M; Stroh, H; Marissens, G; Arnold, D; Burda, O; Kovář, P; Suran, J; Listkowska, A; Tyminski, Z

    2016-03-01

    A new large-volume metal reference standard has been developed. The intended use is for calibration of free-release radioactivity measurement systems and is made up of cast iron tubes placed inside a box of the size of a Euro-pallet (80 × 120 cm). The tubes contain certified activity concentrations of (60)Co (0.290 ± 0.006 Bq g(-1)) and (110m)Ag (3.05 ± 0.09 Bq g(-1)) (reference date: 30 September 2013). They were produced using centrifugal casting from a smelt into which (60)Co was first added and then one piece of neutron irradiated silver wire was progressively diluted. The iron castings were machined to the desirable dimensions. The final material consists of 12 iron tubes of 20 cm outer diameter, 17.6 cm inner diameter, 40 cm length/height and 245.9 kg total mass. This paper describes the reference standard and the process of determining the reference activity values. © The Author 2015. Published by Oxford University Press.

  16. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  17. Measurement standards and the general problem of reference points in chemical analysis

    International Nuclear Information System (INIS)

    Richter, W.; Dube, G.

    2002-01-01

    Besides the measurement standards available in general metrology in the form of the realisations of the units of measurement, measurement standards of chemical composition are needed for the vast field of chemical measurement (measurements of the chemical composition), because it is the main aim of such measurements to quantify non-isolated substances, often in complicated matrices, to which the 'classical' measurement standards and their lower- level derivatives are not directly applicable. At present, material artefacts as well as standard measurement devices serve as chemical measurement standards. These are measurement standards in the full metrological sense only, however, if they are firmly linked to the SI unit in which the composition represented by the standard is expressed. This requirement has the consequence that only a very restricted number of really reliable chemical measurement standards exist at present. Since it is very difficult and time consuming to increase this number substantially and, on the other hand, reliable reference points are increasingly needed for all kinds of chemical measurements, primary methods of measurement and high-level reference measurements will play an increasingly important role for the establishment of worldwide comparability and hence mutual acceptance of chemical measurement results. (author)

  18. Measurement of polybrominated diphenyl ethers in environmental matrix standard reference materials

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, H.; Schantz, M.; Wise, S. (National Institute of Standards and Technology)

    2004-09-15

    Polybrominated diphenyl ethers (PBDEs) are a class of emerging contaminants of concern as many studies have now demonstrated that these compounds are bioaccumulative, persistent and increasing in concentration in the environment. PBDEs are being detected in almost every environmental sample examined, and they have even been measured in samples collected in the Arctic, further demonstrating their persistence and potential for long range transport. More and more studies are continuing to examine the fate and transport of these flame retardant compounds in environmental samples and as such, reference materials are needed to provide quality control on these measurements. The National Institute of Standards and Technology (NIST) supports a national Standard Reference Material (SRM) program for measurement of organic contaminants such as PCBs, PAHs and chlorinated pesticides in environmental matrices. This current study was undertaken to provide reference measurements for PBDEs in selected SRMs that are currently used by various laboratories throughout the United States. These SRMs include matrices such as marine mammal blubber, lake trout tissue, mussel tissue, sediment, house dust and human serum. We report here reference values for 22 PBDE congeners that have been quantified in these seven types of SRMs.

  19. 18 CFR 38.2 - Incorporation by reference of North American Energy Standards Board Wholesale Electric Quadrant...

    Science.gov (United States)

    2010-04-01

    ... reference of North American Energy Standards Board Wholesale Electric Quadrant standards. 38.2 Section 38.2 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY... UTILITIES § 38.2 Incorporation by reference of North American Energy Standards Board Wholesale Electric...

  20. 22 CFR 705.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-reference to employee ethical conduct... INVESTMENT CORPORATION ADMINISTRATIVE PROVISIONS EMPLOYEE ETHICAL CONDUCT STANDARDS AND FINANCIAL DISCLOSURE REGULATIONS § 705.101 Cross-reference to employee ethical conduct standards and financial disclosure...

  1. 5 CFR 1300.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Cross-reference to employees ethical conduct standards and financial disclosure regulations. 1300.1 Section 1300.1 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET ADMINISTRATIVE PROCEDURES STANDARDS OF CONDUCT § 1300.1 Cross-reference...

  2. 16 CFR 1030.101 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... PRODUCT SAFETY COMMISSION GENERAL EMPLOYEE STANDARDS OF CONDUCT General § 1030.101 Cross-references to employee ethical conduct standards and financial disclosure regulations. Employees of the Consumer Product... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct...

  3. Measurement of the depth of narrow slotted sections in eddy current reference standards

    Science.gov (United States)

    Kim, Young-Joo; Kim, Young-gil; Ahn, Bongyoung; Yoon, Dong-Jin

    2007-02-01

    The dimensions of the slots in eddy current (EC) reference standards are too narrow to be measured by general depth measurement methods such as the optical (laser) or stylus methods. However, measurement of the dimensions of the machined slots is a prerequisite to using the blocks as references. The present paper suggests a measurement method for the slotted section using an ultrasonic test. The width and depth of the slots measured in our study are roughly 0.1 mm and 0.5 mm, respectively. The time of flight (TOF) of the ultrasonic wave was measured precisely. The ultrasonic velocity in the material of the EC reference standard was calculated with the measured values of the TOF and its thickness. Reflected waves from the tip of the slot and the bottom surface of the EC standard were successfully classified. Using this method we have successfully determined the depth of the slotted section.

  4. The Value Estimation of an HFGW Frequency Time Standard for Telecommunications Network Optimization

    Science.gov (United States)

    Harper, Colby; Stephenson, Gary

    2007-01-01

    The emerging technology of gravitational wave control is used to augment a communication system using a development roadmap suggested in Stephenson (2003) for applications emphasized in Baker (2005). In the present paper consideration is given to the value of a High Frequency Gravitational Wave (HFGW) channel purely as providing a method of frequency and time reference distribution for use within conventional Radio Frequency (RF) telecommunications networks. Specifically, the native value of conventional telecommunications networks may be optimized by using an unperturbed frequency time standard (FTS) to (1) improve terminal navigation and Doppler estimation performance via improved time difference of arrival (TDOA) from a universal time reference, and (2) improve acquisition speed, coding efficiency, and dynamic bandwidth efficiency through the use of a universal frequency reference. A model utilizing a discounted cash flow technique provides an estimation of the additional value using HFGW FTS technology could bring to a mixed technology HFGW/RF network. By applying a simple net present value analysis with supporting reference valuations to such a network, it is demonstrated that an HFGW FTS could create a sizable improvement within an otherwise conventional RF telecommunications network. Our conservative model establishes a low-side value estimate of approximately 50B USD Net Present Value for an HFGW FTS service, with reasonable potential high-side values to significant multiples of this low-side value floor.

  5. 29 CFR 2703.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards and...-reference to employee ethical conduct standards and financial disclosure regulations. Members and employees... of Ethical Conduct at 5 CFR part 2635; the Commission's regulations at 5 CFR part 8401, which...

  6. 49 CFR 99.735-1 - Cross-reference to ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Cross-reference to ethical conduct standards and... Transportation EMPLOYEE RESPONSIBILITIES AND CONDUCT General § 99.735-1 Cross-reference to ethical conduct... the executive branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Department of...

  7. 78 FR 21850 - Federal Motor Vehicle Safety Standards; Matters Incorporated by Reference

    Science.gov (United States)

    2013-04-12

    ... to the 1985 Annual Book of ASTM Standards, Vol. 05.04, ``Test Methods for Rating Motor, Diesel... for Rating Motor, Diesel, Aviation Fuels, A2. Reference Materials and Blending Accessories, (``ASTM... [Docket No. NHTSA-2011-0185] RIN 2127-AL25 Federal Motor Vehicle Safety Standards; Matters Incorporated by...

  8. Development of the NBS beryllium isotopic standard reference material

    International Nuclear Information System (INIS)

    Inn, K.G.W; Fassett, J.D.; Coursey, B.M.; Walker, R.L.; Raman, S.

    1987-01-01

    The National Bureau of Standards, in conjunction with the Oak Ridge National Laboratory and the Accelerator Mass Spectrometry community, is in the process of developing a beryllium isotopic solution Standard Reference Material. The master 10 Be/ 9 Be solution was characterized isotopically by resonance-ionization and secondary-ion mass-spectrometric-based techniques, and radioactivity measurements were by liquid scintillation counting. The master solution was gravimetrically diluted with 9 Be to a final 10 Be/ 9 Be atomic ratio of 3 x 10 -11 . The preliminary data indicate a half life for 10 Be of 1.3 million years, and AMS measurements are within 10% of the known beryllium isotopic ratio

  9. 12 CFR 336.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Cross-reference to employee ethical conduct... and Conduct § 336.1 Cross-reference to employee ethical conduct standards and financial disclosure... Branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Corporation regulation at 5 CFR part...

  10. 10 CFR 1010.102 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct standards... ENERGY (GENERAL PROVISIONS) CONDUCT OF EMPLOYEES § 1010.102 Cross-references to employee ethical conduct... Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635, the DOE regulation at...

  11. Determination of sampling constants in NBS geochemical standard reference materials

    International Nuclear Information System (INIS)

    Filby, R.H.; Bragg, A.E.; Grimm, C.A.

    1986-01-01

    Recently Filby et al. showed that, for several elements, National Bureau of Standards (NBS) Fly Ash standard reference material (SRM) 1633a was a suitable reference material for microanalysis (sample weights 2 , and the mean sample weight, W vector, K/sub s/ = (S/sub s/%) 2 W vector, could not be determined from these data because it was not possible to quantitate other sources of error in the experimental variances. K/sub s/ values for certified elements in geochemical SRMs provide important homogeneity information for microanalysis. For mineralogically homogeneous SRMs (i.e., small K/sub s/ values for associated elements) such as the proposed clays, it is necessary to determine K/sub s/ by analysis of very small sample aliquots to maximize the subsampling variance relative to other sources of error. This source of error and the blank correction for the sample container can be eliminated by determining K/sub s/ from radionuclide activities of weighed subsamples of a preirradiated SRM

  12. 12 CFR 264.101 - Cross-reference to employees' ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Cross-reference to employees' ethical conduct... § 264.101 Cross-reference to employees' ethical conduct standards and financial disclosure regulations... branch-wide standards of ethical conduct at 5 CFR part 2635 and the Board's regulation at 5 CFR part 6801...

  13. A routine chromium determination in biological materials; application to various reference materials and standard reference materials

    International Nuclear Information System (INIS)

    Tjioe, P.S.; Goeij, J.J.M. de; Volkers, K.J.

    1979-01-01

    The determination limit under standard working conditions of chromium in biological materials is discussed. Neutron activation analysis and atomic spectrometry have been described for some analytical experiences with NBS SRM 1577 reference material. The chromium determination is a part of a larger multi-element scheme for the determination of 12 elements in biological materials

  14. Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standards.

    Science.gov (United States)

    Halvorsen, Ken; Agris, Paul F

    2014-11-15

    Measuring interactions between biological molecules is vitally important to both basic and applied research as well as development of pharmaceuticals. Although a wide and growing range of techniques is available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using isothermal titration calorimetry, differential scanning calorimetry, and ultraviolet-visible (UV-vis) monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features, including low cost, high purity, easily measurable concentrations, and minimal handling concerns, making them ideal for use as a reference material. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Optimal Reference Strain Structure for Studying Dynamic Responses of Flexible Rockets

    Science.gov (United States)

    Tsushima, Natsuki; Su, Weihua; Wolf, Michael G.; Griffin, Edwin D.; Dumoulin, Marie P.

    2017-01-01

    In the proposed paper, the optimal design of reference strain structures (RSS) will be performed targeting for the accurate observation of the dynamic bending and torsion deformation of a flexible rocket. It will provide the detailed description of the finite-element (FE) model of a notional flexible rocket created in MSC.Patran. The RSS will be attached longitudinally along the side of the rocket and to track the deformation of the thin-walled structure under external loads. An integrated surrogate-based multi-objective optimization approach will be developed to find the optimal design of the RSS using the FE model. The Kriging method will be used to construct the surrogate model. For the data sampling and the performance evaluation, static/transient analyses will be performed with MSC.Natran/Patran. The multi-objective optimization will be solved with NSGA-II to minimize the difference between the strains of the launch vehicle and RSS. Finally, the performance of the optimal RSS will be evaluated by checking its strain-tracking capability in different numerical simulations of the flexible rocket.

  16. Sequence Factorization with Multiple References.

    Directory of Open Access Journals (Sweden)

    Sebastian Wandelt

    Full Text Available The success of high-throughput sequencing has lead to an increasing number of projects which sequence large populations of a species. Storage and analysis of sequence data is a key challenge in these projects, because of the sheer size of the datasets. Compression is one simple technology to deal with this challenge. Referential factorization and compression schemes, which store only the differences between input sequence and a reference sequence, gained lots of interest in this field. Highly-similar sequences, e.g., Human genomes, can be compressed with a compression ratio of 1,000:1 and more, up to two orders of magnitude better than with standard compression techniques. Recently, it was shown that the compression against multiple references from the same species can boost the compression ratio up to 4,000:1. However, a detailed analysis of using multiple references is lacking, e.g., for main memory consumption and optimality. In this paper, we describe one key technique for the referential compression against multiple references: The factorization of sequences. Based on the notion of an optimal factorization, we propose optimization heuristics and identify parameter settings which greatly influence 1 the size of the factorization, 2 the time for factorization, and 3 the required amount of main memory. We evaluate a total of 30 setups with a varying number of references on data from three different species. Our results show a wide range of factorization sizes (optimal to an overhead of up to 300%, factorization speed (0.01 MB/s to more than 600 MB/s, and main memory usage (few dozen MB to dozens of GB. Based on our evaluation, we identify the best configurations for common use cases. Our evaluation shows that multi-reference factorization is much better than single-reference factorization.

  17. Evaluation of a new 10 mA DC current reference standard

    CERN Document Server

    Fernqvist, G; Power, F

    2002-01-01

    A new DC current reference standard has been developed as a component in a Current calibration hierarchy in the LHC project at CERN. The standard provides 10 mA DC current with an accuracy less than 0.5 ppm, drift less than 2 ppm/year and compliance error less than 0.1 ppm for 0-10 V. The paper gives the results from two years evaluation of a series of 5 units.

  18. 39 CFR 3000.735-101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Employees of the Postal Regulatory Commission (Commission) are subject and should refer to the executive branch-wide Standards of Ethical...

  19. Standard reference materials analysis for MINT Radiocarbon Laboratory

    International Nuclear Information System (INIS)

    Noraishah Othman; Kamisah Alias; Nasasni Nasrul

    2004-01-01

    As a follow-up to the setting up of the MINT Radiocarbon Dating facility. an exercise on the IAEA standard reference materials was carried out. Radiocarbon laboratories frequently used these 8 natural samples to verify their systems. The materials were either pretreated or analysed directly to determine the activity of 14 C isotopes of the five samples expressed in % Modern (pMC) terms and to make recommendations on further use of these materials. We present the results of the five materials and discuss the analyses that were undertaken. (Author)

  20. 45 CFR 1105.1 - Cross-reference to employee ethical conduct standards and financial disclosure and financial...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Cross-reference to employee ethical conduct... STANDARDS OF CONDUCT FOR EMPLOYEES § 1105.1 Cross-reference to employee ethical conduct standards and... ethical conduct at 5 CFR part 2635; the executive branch employees responsibilities and conduct...

  1. Improving the efficiency of quantitative (1)H NMR: an innovative external standard-internal reference approach.

    Science.gov (United States)

    Huang, Yande; Su, Bao-Ning; Ye, Qingmei; Palaniswamy, Venkatapuram A; Bolgar, Mark S; Raglione, Thomas V

    2014-01-01

    The classical internal standard quantitative NMR (qNMR) method determines the purity of an analyte by the determination of a solution containing the analyte and a standard. Therefore, the standard must meet the requirements of chemical compatibility and lack of resonance interference with the analyte as well as a known purity. The identification of such a standard can be time consuming and must be repeated for each analyte. In contrast, the external standard qNMR method utilizes a standard with a known purity to calibrate the NMR instrument. The external standard and the analyte are measured separately, thereby eliminating the matter of chemical compatibility and resonance interference between the standard and the analyte. However, the instrumental factors, including the quality of NMR tubes, must be kept the same. Any deviations will compromise the accuracy of the results. An innovative qNMR method reported herein utilizes an internal reference substance along with an external standard to assume the role of the standard used in the traditional internal standard qNMR method. In this new method, the internal reference substance must only be chemically compatible and be free of resonance-interference with the analyte or external standard whereas the external standard must only be of a known purity. The exact purity or concentration of the internal reference substance is not required as long as the same quantity is added to the external standard and the analyte. The new method reduces the burden of searching for an appropriate standard for each analyte significantly. Therefore the efficiency of the qNMR purity assay increases while the precision of the internal standard method is retained. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. One directional polarized neutron reflectometry with optimized reference layer method

    International Nuclear Information System (INIS)

    Masoudi, S. Farhad; Jahromi, Saeed S.

    2012-01-01

    In the past decade, several neutron reflectometry methods for determining the modulus and phase of the complex reflection coefficient of an unknown multilayer thin film have been worked out among which the method of variation of surroundings and reference layers are of highest interest. These methods were later modified for measurement of the polarization of the reflected beam instead of the measurement of the intensities. In their new architecture, these methods not only suffered from the necessity of change of experimental setup but also another difficulty was added to their experimental implementations. This deficiency was related to the limitations of the technology of the neutron reflectometers that could only measure the polarization of the reflected neutrons in the same direction as the polarization of the incident beam. As the instruments are limited, the theory has to be optimized so that the experiment could be performed. In a recent work, we developed the method of variation of surroundings for one directional polarization analysis. In this new work, the method of reference layer with polarization analysis has been optimized to determine the phase and modulus of the unknown film with measurement of the polarization of the reflected neutrons in the same direction as the polarization of the incident beam.

  3. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    International Nuclear Information System (INIS)

    Williams, R.W.; Gaffney, A.M.; Kristo, M.J.; Hutcheon, I.D.

    2009-01-01

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the 230 Th- 234 U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial 230 Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U 3 O 8 ) may be assumed with confidence. We present here 230 Th- 234 U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history

  4. Impact of a product-specific reference standard for the measurement of a PEGylated rFVIII activity: the Swiss Multicentre Field Study.

    Science.gov (United States)

    Bulla, O; Poncet, A; Alberio, L; Asmis, L M; Gähler, A; Graf, L; Nagler, M; Studt, J-D; Tsakiris, D A; Fontana, P

    2017-07-01

    Measuring factor VIII (FVIII) activity can be challenging when it has been modified, such as when FVIII is pegylated to increase its circulating half-life. Use of a product-specific reference standard may help avoid this issue. Evaluate the impact of using a product-specific reference standard for measuring the FVIII activity of BAX 855 - a pegylated FVIII - in eight of Switzerland's main laboratories. Factor VIII-deficient plasma, spiked with five different concentrations of BAX 855, plus a control FVIII sample, was sent to the participating laboratories. They measured FVIII activity by using either with a one-stage (OSA) or the chromogenic assay (CA) against their local or a product-specific reference standard. When using a local reference standard, there was an overestimation of BAX 855 activity compared to the target concentrations, both with the OSA and CA. The use of a product-specific reference standard reduced this effect: mean recovery ranged from 127.7% to 213.5% using the OSA with local reference standards, compared to 110% to 183.8% with a product-specific reference standard, and from 146.3% to 182.4% using the CA with local reference standards compared to 72.7% to 103.7% with a product-specific reference standard. In this in vitro study, the type of reference standard had a major impact on the measurement of BAX 855 activity. Evaluation was more accurate and precise when using a product-specific reference standard. © 2017 John Wiley & Sons Ltd.

  5. Nuclear microprobe analysis of the standard reference materials

    International Nuclear Information System (INIS)

    Jaksic, M.; Fazinic, S.; Bogdanovic, I.; Tadic, T.

    2002-01-01

    Most of the presently existing Standard Reference Materials (SRM) for nuclear analytical methods are certified for the analyzed mass of the order of few hundred mg. Typical mass of sample which is analyzed by PIXE or XRF methods is very often below 1 mg. By the development of focused proton or x-ray beams, masses which can be typically analyzed go down to μg or even ng level. It is difficult to make biological or environmental SRMs which can give desired homogeneity at such low scale. However, use of fundamental parameter quantitative evaluation procedures (absolute method), minimize needs for SRMs. In PIXE and micro PIXE setup at our Institute, fundamental parameter approach is used. For exact calibration of the quantitative analysis procedure just one standard sample is needed. In our case glass standards which showed homogeneity down to micron scale were used. Of course, it is desirable to use SRMs for quality assurance, and therefore need for homogenous materials can be justified even for micro PIXE method. In this presentation, brief overview of PIXE setup calibration is given, along with some recent results of tests of several SRMs

  6. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  7. Optimal Energy Mix with Renewable Portfolio Standards in Korea

    Directory of Open Access Journals (Sweden)

    Zong Woo Geem

    2016-05-01

    Full Text Available Korea is a heavily energy-dependent country whose primary energy consumption ranks ninth in the world. However, at the same time, it promised to reduce carbon emission and planned to use more renewable energy. Thus, the objective of this study is to propose an optimal energy mix planning model in electricity generation from various energy sources, such as gas, coal, nuclear, hydro, wind, photovoltaic, and biomass, which considers more renewable and sustainable portions by imposing governmental regulation named renewable portfolio standard (RPS. This optimization model minimizes various costs such as construction cost, operation and management cost, fuel cost, and carbon emission cost while satisfying minimal demand requirement, maximal annual installation potential, and renewable portfolio standard constraints. Results showed that this optimization model could successfully generate energy mix plan from 2012 to 2030 while minimizing the objective costs and satisfying all the constraints. Therefore, this optimization model contributes more efficient and objective method to the complex decision-making process with a sustainability option. This proposed energy mix model is expected to be applied not only to Korea, but also to many other countries in the future for more economical planning of their electricity generation while affecting climate change less.

  8. A Linear Programming Reformulation of the Standard Quadratic Optimization Problem

    NARCIS (Netherlands)

    de Klerk, E.; Pasechnik, D.V.

    2005-01-01

    The problem of minimizing a quadratic form over the standard simplex is known as the standard quadratic optimization problem (SQO).It is NPhard, and contains the maximum stable set problem in graphs as a special case.In this note we show that the SQO problem may be reformulated as an (exponentially

  9. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Hu; Hongliao, He [National Research Center for Geoanalysis, Beijing (China)

    2005-10-15

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  10. Determination of platinum-group elements in the geological standard reference materials by isotope dilution-ICPMS

    International Nuclear Information System (INIS)

    Hu Mingyue; He Hongliao

    2005-01-01

    Platinum group elements (PGEs) includes platinum, palladium, iridium, osmium, rhodium and ruthenium. It has very high economic and scientific value in the field of geoscience and environmental science. But the analysis data referred by the different lab are very disperse because of the difficulty of the determination of PGEs. It makes very difficult to fix the value of the PGEs in the standard reference materials. In the article, the values of the PGEs in the standard reference materials of ocean sediment are determined by isotope dilution technique and dependable values of these elements are provided. (authors)

  11. Measuring the activity of BioBrick promoters using an in vivo reference standard

    Directory of Open Access Journals (Sweden)

    Kelly Jason R

    2009-03-01

    Full Text Available Abstract Background The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. Results We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101 to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Conclusion Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement

  12. Comparison of DVH parameters and loading patterns of standard loading, manual and inverse optimization for intracavitary brachytherapy on a subset of tandem/ovoid cases

    International Nuclear Information System (INIS)

    Jamema, Swamidas V.; Kirisits, Christian; Mahantshetty, Umesh; Trnkova, Petra; Deshpande, Deepak D.; Shrivastava, Shyam K.; Poetter, Richard

    2010-01-01

    Purpose: Comparison of inverse planning with the standard clinical plan and with the manually optimized plan based on dose-volume parameters and loading patterns. Materials and methods: Twenty-eight patients who underwent MRI based HDR brachytherapy for cervix cancer were selected for this study. Three plans were calculated for each patient: (1) standard loading, (2) manual optimized, and (3) inverse optimized. Dosimetric outcomes from these plans were compared based on dose-volume parameters. The ratio of Total Reference Air Kerma of ovoid to tandem (TRAK O/T ) was used to compare the loading patterns. Results: The volume of HR CTV ranged from 9-68 cc with a mean of 41(±16.2)cc. Mean V100 for standard, manual optimized and inverse plans was found to be not significant (p = 0.35, 0.38, 0.4). Dose to bladder (7.8 ± 1.6 Gy) and sigmoid (5.6 ± 1.4 Gy) was high for standard plans; Manual optimization reduced the dose to bladder (7.1 ± 1.7 Gy p = 0.006) and sigmoid (4.5 ± 1.0 Gy p = 0.005) without compromising the HR CTV coverage. The inverse plan resulted in a significant reduction to bladder dose (6.5 ± 1.4 Gy, p = 0.002). TRAK was found to be 0.49(±0.02), 0.44(±0.04) and 0.40(±0.04)cGy m -2 for the standard loading, manual optimized and inverse plans, respectively. It was observed that TRAK O/T was 0.82(±0.05), 1.7(±1.04) and 1.41(±0.93) for standard loading, manual optimized and inverse plans, respectively, while this ratio was 1 for the traditional loading pattern. Conclusions: Inverse planning offers good sparing of critical structures without compromising the target coverage. The average loading pattern of the whole patient cohort deviates from the standard Fletcher loading pattern.

  13. Comparison of DVH parameters and loading patterns of standard loading, manual and inverse optimization for intracavitary brachytherapy on a subset of tandem/ovoid cases.

    Science.gov (United States)

    Jamema, Swamidas V; Kirisits, Christian; Mahantshetty, Umesh; Trnkova, Petra; Deshpande, Deepak D; Shrivastava, Shyam K; Pötter, Richard

    2010-12-01

    Comparison of inverse planning with the standard clinical plan and with the manually optimized plan based on dose-volume parameters and loading patterns. Twenty-eight patients who underwent MRI based HDR brachytherapy for cervix cancer were selected for this study. Three plans were calculated for each patient: (1) standard loading, (2) manual optimized, and (3) inverse optimized. Dosimetric outcomes from these plans were compared based on dose-volume parameters. The ratio of Total Reference Air Kerma of ovoid to tandem (TRAK(O/T)) was used to compare the loading patterns. The volume of HR CTV ranged from 9-68 cc with a mean of 41(±16.2) cc. Mean V100 for standard, manual optimized and inverse plans was found to be not significant (p=0.35, 0.38, 0.4). Dose to bladder (7.8±1.6 Gy) and sigmoid (5.6±1.4 Gy) was high for standard plans; Manual optimization reduced the dose to bladder (7.1±1.7 Gy p=0.006) and sigmoid (4.5±1.0 Gy p=0.005) without compromising the HR CTV coverage. The inverse plan resulted in a significant reduction to bladder dose (6.5±1.4 Gy, p=0.002). TRAK was found to be 0.49(±0.02), 0.44(±0.04) and 0.40(±0.04) cGy m(-2) for the standard loading, manual optimized and inverse plans, respectively. It was observed that TRAK(O/T) was 0.82(±0.05), 1.7(±1.04) and 1.41(±0.93) for standard loading, manual optimized and inverse plans, respectively, while this ratio was 1 for the traditional loading pattern. Inverse planning offers good sparing of critical structures without compromising the target coverage. The average loading pattern of the whole patient cohort deviates from the standard Fletcher loading pattern. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  14. Value assignment of nutrient concentrations in five standard reference materials and six reference materials.

    Science.gov (United States)

    Sharpless, K E; Gill, L M

    2000-01-01

    A number of food-matrix reference materials (RMs) are available from the National Institute of Standards and Technology (NIST) and from Agriculture Canada through NIST. Most of these materials were originally value-assigned for their elemental composition (major, minor, and trace elements), but no additional nutritional information was provided. Two of the materials were certified for selected organic constituents. Ten of these materials (Standard Reference Material [SRM] 1,563 Cholesterol and Fat-Soluble Vitamins in Coconut Oil [Natural and Fortified], SRM 1,566b Oyster Tissue, SRM 1,570a Spinach Leaves, SRM 1,974a Organics in Mussel Tissue (Mytilus edulis), RM 8,415 Whole Egg Powder, RM 8,418 Wheat Gluten, RM 8,432 Corn Starch, RM 8,433 Corn Bran, RM 8,435 Whole Milk Powder, and RM 8,436 Durum Wheat Flour) were recently distributed by NIST to 4 laboratories with expertise in food analysis for the measurement of proximates (solids, fat, protein, etc.), calories, and total dietary fiber, as appropriate. SRM 1846 Infant Formula was distributed as a quality control sample for the proximates and for analysis for individual fatty acids. Two of the materials (Whole Egg Powder and Whole Milk Powder) were distributed in an earlier interlaboratory comparison exercise in which they were analyzed for several vitamins. Value assignment of analyte concentrations in these 11 SRMs and RMs, based on analyses by the collaborating laboratories, is described in this paper. These materials are intended primarily for validation of analytical methods for the measurement of nutrients in foods of similar composition (based on AOAC INTERNATIONAL's fat-protein-carbohydrate triangle). They may also be used as "primary control materials" in the value assignment of in-house control materials of similar composition. The addition of proximate information for 10 existing reference materials means that RMs are now available from NIST with assigned values for proximates in 6 of the 9 sectors of

  15. Procedure and reference standard to determine the structural resolution in coordinate metrology

    Science.gov (United States)

    Illemann, Jens; Bartscher, Markus; Jusko, Otto; Härtig, Frank; Neuschaefer-Rube, Ulrich; Wendt, Klaus

    2014-06-01

    A new procedure and reference standards for specifying the structural resolution in coordinate metrology traceable to the SI unit the metre are proposed. With the definition of the structural resolution, a significant gap will be closed to complete ‘acceptance and verification tests’ of the coordinate measuring systems (CMSs) which are specified in the ISO 10360 series dealing with tactile sensors, optical sensors, and x-ray computed tomography measurement systems (CTs). The proposed new procedure uses reference standards with circular rounded edges. The idea is to measure the radius of curvature on a calibrated round edge structure. From the deviation between the measured and the calibrated radius, an analogue Gaussian broadening of the measurement system is determined. This value is a well-defined and easy-to-apply measure to define the structural resolution for dimensional measurements. It is applicable to CMSs which are based on different sensing principles, e.g. tactile, optical and CT systems. On the other hand, it has a physical meaning similar to the classical optical point-spread function. It makes it possible to predict which smallest details the CMS is capable of measuring reliably for an arbitrary object shape. The theoretical background of the new procedure is given, an appropriate reference standard is described and comparative, quantitative measurement data of CMSs featuring different sensors are shown.

  16. Physical fitness reference standards in European children: the IDEFICS study.

    Science.gov (United States)

    De Miguel-Etayo, P; Gracia-Marco, L; Ortega, F B; Intemann, T; Foraita, R; Lissner, L; Oja, L; Barba, G; Michels, N; Tornaritis, M; Molnár, D; Pitsiladis, Y; Ahrens, W; Moreno, L A

    2014-09-01

    A low fitness status during childhood and adolescence is associated with important health-related outcomes, such as increased future risk for obesity and cardiovascular diseases, impaired skeletal health, reduced quality of life and poor mental health. Fitness reference values for adolescents from different countries have been published, but there is a scarcity of reference values for pre-pubertal children in Europe, using harmonised measures of fitness in the literature. The IDEFICS study offers a good opportunity to establish normative values of a large set of fitness components from eight European countries using common and well-standardised methods in a large sample of children. Therefore, the aim of this study is to report sex- and age-specific fitness reference standards in European children. Children (10,302) aged 6-10.9 years (50.7% girls) were examined. The test battery included: the flamingo balance test, back-saver sit-and-reach test (flexibility), handgrip strength test, standing long jump test (lower-limb explosive strength) and 40-m sprint test (speed). Moreover, cardiorespiratory fitness was assessed by a 20-m shuttle run test. Percentile curves for the 1st, 3rd, 10th, 25th, 50th, 75th, 90th, 97th and 99th percentiles were calculated using the General Additive Model for Location Scale and Shape (GAMLSS). Our results show that boys performed better than girls in speed, lower- and upper-limb strength and cardiorespiratory fitness, and girls performed better in balance and flexibility. Older children performed better than younger children, except for cardiorespiratory fitness in boys and flexibility in girls. Our results provide for the first time sex- and age-specific physical fitness reference standards in European children aged 6-10.9 years.

  17. 13 CFR 105.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... ethical conduct standards and financial disclosure regulations. 105.101 Section 105.101 Business Credit... RESPONSIBILITIES Standards of Conduct § 105.101 Cross-reference to employee ethical conduct standards and financial... to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR part 2635 and the...

  18. 22 CFR 1001.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1001.1 Cross-references to employee ethical conduct... Foundation should refer to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  19. New Carbonate Standard Reference Materials for Boron Isotope Geochemistry

    Science.gov (United States)

    Stewart, J.; Christopher, S. J.; Day, R. D.

    2015-12-01

    The isotopic composition of boron (δ11B) in marine carbonates is well established as a proxy for past ocean pH. Yet, before palaeoceanographic interpretation can be made, rigorous assessment of analytical uncertainty of δ11B data is required; particularly in light of recent interlaboratory comparison studies that reported significant measurement disagreement between laboratories [1]. Well characterised boron standard reference materials (SRMs) in a carbonate matrix are needed to assess the accuracy and precision of carbonate δ11B measurements throughout the entire procedural chemistry; from sample cleaning, to ionic separation of boron from the carbonate matrix, and final δ11B measurement by multi-collector inductively coupled plasma mass spectrometry. To date only two carbonate reference materials exist that have been value-assigned by the boron isotope measurement community [2]; JCp-1 (porites coral) and JCt-1 (Giant Clam) [3]. The National Institute of Standards and Technology (NIST) will supplement these existing standards with new solution based inorganic carbonate boron SRMs that replicate typical foraminiferal and coral B/Ca ratios and δ11B values. These new SRMs will not only ensure quality control of full procedural chemistry between laboratories, but have the added benefits of being both in abundant supply and free from any restrictions associated with shipment of biogenic samples derived from protected species. Here we present in-house δ11B measurements of these new boron carbonate SRM solutions. These preliminary data will feed into an interlaboratory comparison study to establish certified values for these new NIST SRMs. 1. Foster, G.L., et al., Chemical Geology, 2013. 358(0): p. 1-14. 2. Gutjahr, M., et al., Boron Isotope Intercomparison Project (BIIP): Development of a new carbonate standard for stable isotopic analyses. Geophysical Research Abstracts, EGU General Assembly 2014, 2014. 16(EGU2014-5028-1). 3. Inoue, M., et al., Geostandards and

  20. 230Th-234U Model-Ages of Some Uranium Standard Reference Materials

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R W; Gaffney, A M; Kristo, M J; Hutcheon, I D

    2009-05-28

    The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.

  1. 78 FR 57293 - Distribution of Reference Biological Standards and Biological Preparations

    Science.gov (United States)

    2013-09-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES 42 CFR Part 7 [Docket No. CDC-2013-0013] RIN 0920-AA52 Distribution of Reference Biological Standards and Biological Preparations AGENCY: Centers for Disease Control and Prevention (HHS/CDC), Department of Health and Human Services (HHS). ACTION: Confirmation of...

  2. 36 CFR 811.1 - Cross-references to employees' ethical conduct standards, financial disclosure and financial...

    Science.gov (United States)

    2010-07-01

    ...' ethical conduct standards, financial disclosure and financial interests regulations and other conduct... EMPLOYEE RESPONSIBILITIES AND CONDUCT § 811.1 Cross-references to employees' ethical conduct standards... Council on Historic Preservation are subject to the executive branch-wide standards of ethical conduct...

  3. Design and evaluation of a 10-mA DC current reference standard

    CERN Document Server

    Fernqvist, G; Pickering, J; Power, F

    2003-01-01

    A new DC current reference standard has been developed for high- current power converter calibration in the large hadron collider (LHC) project at the European Organization for Nuclear Research (CERN). This standard provides a near ideal 10-mA DC current with long-term drift of one part in 10/sup 6/ per year. The paper describes the requirements and the detailed design and evaluation of the unit. Since similar 10-V standards are commercially available, the paper concentrates on the unique current output capability of this device. (4 refs).

  4. Determination of multielement in optical waveguide and standard reference materials by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kobayashi, K.; Kudo, K.

    1979-01-01

    Trace amounts of transition elements (Co, Cr, Cu, Fe, Mn and V) and other seven elements in optical waveguide samples were determined by INAA. The contents of impurities in ultre-pure materials are less than those of high-purity materials and of G.R. grade. The increase of contamination of trace transition elements and iridium from furnace or crucible are observed in the production of optical glass fibers. Up to seventeen elements were determined in five NBS biological standard reference materials: Oyster Tissue: SRM-1566, Brewers Yeast: SRM-1569, Spinach: SRM-1570, Orchard Leaves: SRM-1571 and Tuna Fish, and in four Japanese biological standard reference materials: Tea Leaves B and C, Pepperbush and Shark Meat. The analytical results in NBS and Japanese standard reference materials are in good agreement with published values and certified values by NBS. (author)

  5. A simple preparation of calibration curve standards of 134Cs and 137Cs by serial dilution of a standard reference material

    International Nuclear Information System (INIS)

    Labrecque, J.J.; Rosales, P.A.

    1990-01-01

    Two sets of calibration standards for 134 Cs and 137 Cs were prepared by small serial dilution of a natural matrix standard reference material, IAEA-154 whey powder. The first set was intended to screen imported milk powders which were suspected to be contaminated with 134 Cs and 137 Cs. Their concentration ranged from 40 to 400 Bq/kg. The other set of calibration standards was prepared to measure the environmental levels of 137 Cs in commercial Venezuelan milk powders. Their concentration ranged from 3 to 10 Bq/kg of 137 Cs. The accuracy of these calibration curves was checked by IAEA-152 and A-14 milk powders. Their measured values were in good agreement with their certified values. Finally, it is shown that these preparation techniques using serial dilution of a standard reference material were simple, rapid, precise, accurate and cost-effective. (author) 5 refs.; 5 figs.; 3 tabs

  6. Reference value standards and primary standards for pH measurements in D2O and aqueous-organic solvent mixtures: new accessions and assessments

    International Nuclear Information System (INIS)

    Mussini, P.R.; Mussini, T.; Rondinini, S.

    1997-01-01

    Recommended Reference Value Standards based on the potassium hydro-genphthalate buffer at various temperatures are reported for pH measurements in various binary solvent mixtures of water with eight organic solvents: methanol, ethanol, 2-propanol, 1,2-ethanediol, 2-methoxyethanol (''methylcellosolve''), acetonitrile, 1,4-dioxane, and dimethyl sulfoxide, together with Reference Value Standard based on the potassium deuterium phthalate buffer for pD measurements in D 2 O. In addition are reported Primary Standards for pH based on numerous buffers in various binary solvent mixtures of water with methanol, ethanol, and dimethyl sulfoxide, together with Primary Standards for pD in D 2 O based on the citrate, phosphate and carbonate buffers. (author)

  7. Standard Specification for Physical Characteristics of Nonconcentrator Terrestrial Photovoltaic Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This specification describes the physical requirements for primary and secondary terrestrial nonconcentrator photovoltaic reference cells. A reference cell is defined as a device that meets the requirements of this specification and is calibrated in accordance with Test Method E1125 or Test Method E1362. 1.2 Reference cells are used in the determination of the electrical performance of photovoltaic devices, as stated in Test Methods E948 and E1036. 1.3 Two reference cell physical specifications are described: 1.3.1 Small-Cell Package Design—A small, durable package with a low thermal mass, wide optical field-of-view, and standardized dimensions intended for photovoltaic devices up to 20 by 20 mm, and 1.3.2 Module-Package Design—A package intended to simulate the optical and thermal properties of a photovoltaic module design, but electric connections are made to only one photovoltaic cell in order to eliminate problems with calibrating series and parallel connections of cells. Physical dimensions ...

  8. 36 CFR 400.1 - Cross-references to employees' ethical conduct standards, financial disclosure regulations and...

    Science.gov (United States)

    2010-07-01

    ...' ethical conduct standards, financial disclosure regulations and other conduct rules. 400.1 Section 400.1... CONDUCT § 400.1 Cross-references to employees' ethical conduct standards, financial disclosure regulations... executive branch-wide standards of ethical conduct and financial disclosure regulations at 5 CFR parts 2634...

  9. 29 CFR 1600.101 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Cross-reference to employee ethical conduct standards and... to employee ethical conduct standards and financial disclosure regulations. Employees of the Equal Employment Opportunity Commission (EEOC) are subject to the executive branch-wide Standards of Ethical...

  10. 24 CFR 0.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... ethical conduct standards and financial disclosure regulations. 0.1 Section 0.1 Housing and Urban... Cross-reference to employees ethical conduct standards and financial disclosure regulations. Employees...-wide standards of ethical conduct at 5 CFR part 2635, the Department's regulation at 5 CFR part 7501...

  11. A non-standard optimal control problem arising in an economics application

    Directory of Open Access Journals (Sweden)

    Alan Zinober

    2013-04-01

    Full Text Available A recent optimal control problem in the area of economics has mathematical properties that do not fall into the standard optimal control problem formulation. In our problem the state value at the final time the state, y(T = z, is free and unknown, and additionally the Lagrangian integrand in the functional is a piecewise constant function of the unknown value y(T. This is not a standard optimal control problem and cannot be solved using Pontryagin's Minimum Principle with the standard boundary conditions at the final time. In the standard problem a free final state y(T yields a necessary boundary condition p(T = 0, where p(t is the costate. Because the integrand is a function of y(T, the new necessary condition is that y(T should be equal to a certain integral that is a continuous function of y(T. We introduce a continuous approximation of the piecewise constant integrand function by using a hyperbolic tangent approach and solve an example using a C++ shooting algorithm with Newton iteration for solving the Two Point Boundary Value Problem (TPBVP. The minimising free value y(T is calculated in an outer loop iteration using the Golden Section or Brent algorithm. Comparative nonlinear programming (NP discrete-time results are also presented.

  12. A Comparative Study of Standardized Infinity Reference and Average Reference for EEG of Three Typical Brain States

    Directory of Open Access Journals (Sweden)

    Gaoxing Zheng

    2018-03-01

    Full Text Available The choice of different reference electrodes plays an important role in deciphering the functional meaning of electroencephalography (EEG signals. In recent years, the infinity zero reference using the reference electrode standard technique (REST has been increasingly applied, while the average reference (AR was generally advocated as the best available reference option in previous classical EEG studies. Here, we designed EEG experiments and performed a direct comparison between the influences of REST and AR on EEG-revealed brain activity features for three typical brain behavior states (eyes-closed, eyes-open and music-listening. The analysis results revealed the following observations: (1 there is no significant difference in the alpha-wave-blocking effect during the eyes-open state compared with the eyes-closed state for both REST and AR references; (2 there was clear frontal EEG asymmetry during the resting state, and the degree of lateralization under REST was higher than that under AR; (3 the global brain functional connectivity density (FCD and local FCD have higher values for REST than for AR under different behavior states; and (4 the value of the small-world network characteristic in the eyes-closed state is significantly (in full, alpha, beta and gamma frequency bands higher than that in the eyes-open state, and the small-world effect under the REST reference is higher than that under AR. In addition, the music-listening state has a higher small-world network effect than the eyes-closed state. The above results suggest that typical EEG features might be more clearly presented by applying the REST reference than by applying AR when using a 64-channel recording.

  13. Endogenous versus exogenous generic reference pricing for pharmaceuticals.

    Science.gov (United States)

    Antoñanzas, F; Juárez-Castelló, C A; Rodríguez-Ibeas, R

    2017-12-01

    In this paper we carry out a vertical differentiation duopoly model applied to pharmaceutical markets to analyze how endogenous and exogenous generic reference pricing influence competition between generic and branded drugs producers. Unlike the literature, we characterize for the exogenous case the equilibrium prices for all feasible relevant reference prices. Competition is enhanced after the introduction of a reference pricing system. We also compare both reference pricing systems on welfare grounds, assuming two different objective functions for health authorities: (i) standard social welfare and (ii) gross consumer surplus net of total pharmaceutical expenditures. We show that regardless of the objective function, health authorities will never choose endogenous reference pricing. When health authorities are paternalistic, the exogenous reference price that maximizes standard social welfare is such that the price of the generic drug is the reference price while the price of the branded drug is higher than the reference price. When health authorities are not paternalistic, the optimal exogenous reference price is such that the price of the branded drug is the reference price while the price of the generic drug is lower than the reference price.

  14. 18 CFR 1300.101 - Cross references to employee ethical conduct standards and other applicable regulations.

    Science.gov (United States)

    2010-04-01

    ... employee ethical conduct standards and other applicable regulations. 1300.101 Section 1300.101 Conservation... TENNESSEE VALLEY AUTHORITY § 1300.101 Cross references to employee ethical conduct standards and other...-wide standards of ethical conduct at 5 CFR part 2635 and to the TVA regulations at 5 CFR part 7901...

  15. Re-evaluation and extension of the scope of elements in US Geological Survey Standard Reference Water Samples

    Science.gov (United States)

    Peart, D.B.; Antweiler, Ronald C.; Taylor, Howard E.; Roth, D.A.; Brinton, T.I.

    1998-01-01

    More than 100 US Geological Survey (USGS) Standard Reference Water Samples (SRWSs) were analyzed for numerous trace constituents, including Al, As, B, Ba, Be, Bi, Br, Cd, Cr, Co, Cu, I, Fe, Pb, Li, Mn, Mo, Ni, Rb, Sb, Se, Sr, Te, Tl, U, V, Zn and major elements (Ca, Mg, Na, SiO2, SO4, Cl) by inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry. In addition, 15 USGS SRWSs and National Institute of Standards and Technology (NIST) standard reference material (SRM) 1641b were analyzed for mercury using cold vapor atomic fluorescence spectrometry. Also USGS SRWS Hg-7 was analyzed using isotope dilution-inductively coupled plasma mass spectrometry. The results were compared with the reported certified values of the following standard reference materials: NIST SRM 1643a, 1643b, 1643c and 1643d and National Research Council of Canada Riverine Water Reference Materials for Trace Metals SLRS-1, SLRS-2 and SLRS-3. New concentration values for trace and major elements in the SRWSs, traceable to the certified standards, are reported. Additional concentration values are reported for elements that were neither previously published for the SRWSs nor traceable to the certified reference materials. Robust statistical procedures were used that were insensitive to outliers. These data can be used for quality assurance/quality control purposes in analytical laboratories.

  16. Quantification of the predominant monomeric catechins in baking chocolate standard reference material by LC/APCI-MS.

    Science.gov (United States)

    Nelson, Bryant C; Sharpless, Katherine E

    2003-01-29

    Catechins are polyphenolic plant compounds (flavonoids) that may offer significant health benefits to humans. These benefits stem largely from their anticarcinogenic, antioxidant, and antimutagenic properties. Recent epidemiological studies suggest that the consumption of flavonoid-containing foods is associated with reduced risk of cardiovascular disease. Chocolate is a natural cocoa bean-based product that reportedly contains high levels of monomeric, oligomeric, and polymeric catechins. We have applied solid-liquid extraction and liquid chromatography coupled with atmospheric pressure chemical ionization-mass spectrometry to the identification and determination of the predominant monomeric catechins, (+)-catechin and (-)-epicatechin, in a baking chocolate Standard Reference Material (NIST Standard Reference Material 2384). (+)-Catechin and (-)-epicatechin are detected and quantified in chocolate extracts on the basis of selected-ion monitoring of their protonated [M + H](+) molecular ions. Tryptophan methyl ester is used as an internal standard. The developed method has the capacity to accurately quantify as little as 0.1 microg/mL (0.01 mg of catechin/g of chocolate) of either catechin in chocolate extracts, and the method has additionally been used to certify (+)-catechin and (-)-epicatechin levels in the baking chocolate Standard Reference Material. This is the first reported use of liquid chromatography/mass spectrometry for the quantitative determination of monomeric catechins in chocolate and the only report certifying monomeric catechin levels in a food-based Standard Reference Material.

  17. Compilation of elemental concentration data for NBS Biological and Environmental Standard Reference Materials

    International Nuclear Information System (INIS)

    Gladney, E.S.

    1980-07-01

    Concentration data on up to 76 elementals in 19 NBS Standard Reference Materials have been collected from 325 journal articles and technical reports. These data are summarized into mean +- one standard deviation values and compared with available data from NBS and other review articles. Data are presented on the analytical procedures employed and all raw data are presented in appendixes

  18. Strategies for building reference standards for autoantibodies

    Directory of Open Access Journals (Sweden)

    Joanna eSheldon

    2015-04-01

    Full Text Available Producing robust, certified, traceable reference material for autoantibody testing is a vital element in maintaining the validity of results that are generated in the daily clinical laboratory routine. This is a huge challenge because of the high number of variables involved in the detection and measurement of the autoantibodies. The production of such materials is time consuming and needs rigorous attention to detail; this is best achieved by an overarching independent body who will oversee the process in a not for profit manner.Much effort has been made to build international standards for quantitative and qualitative assays based on monoclonal antibodies, obtained from affinity purification and plasmapheresis. The big challenge is to respect individual differences in immune response to the same antigen. A promising ongoing initiative is the construction of pools with monospecific samples from different individuals.

  19. 78 FR 47319 - Fee Schedule for Reference Biological Standards and Biological Preparations

    Science.gov (United States)

    2013-08-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Fee Schedule for Reference Biological Standards and Biological Preparations AGENCY: Centers for Disease Control and... for Disease Control and Prevention (CDC), located within the Department of Health and Human Services...

  20. 18 CFR 3c.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... employee ethical conduct standards and financial disclosure regulations. 3c.1 Section 3c.1 Conservation of... STANDARDS OF CONDUCT § 3c.1 Cross-reference to employee ethical conduct standards and financial disclosure... branch-wide financial disclosure regulations at 5 CFR part 2634, the Standards of Ethical Conduct for...

  1. 45 CFR 706.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Cross-references to employee ethical conduct... 706.1 Public Welfare Regulations Relating to Public Welfare (Continued) COMMISSION ON CIVIL RIGHTS EMPLOYEE RESPONSIBILITIES AND CONDUCT § 706.1 Cross-references to employee ethical conduct standards...

  2. MATLAB Toolboxes for Reference Electrode Standardization Technique (REST) of Scalp EEG.

    Science.gov (United States)

    Dong, Li; Li, Fali; Liu, Qiang; Wen, Xin; Lai, Yongxiu; Xu, Peng; Yao, Dezhong

    2017-01-01

    Reference electrode standardization technique (REST) has been increasingly acknowledged and applied as a re-reference technique to transform an actual multi-channels recordings to approximately zero reference ones in electroencephalography/event-related potentials (EEG/ERPs) community around the world in recent years. However, a more easy-to-use toolbox for re-referencing scalp EEG data to zero reference is still lacking. Here, we have therefore developed two open-source MATLAB toolboxes for REST of scalp EEG. One version of REST is closely integrated into EEGLAB, which is a popular MATLAB toolbox for processing the EEG data; and another is a batch version to make it more convenient and efficient for experienced users. Both of them are designed to provide an easy-to-use for novice researchers and flexibility for experienced researchers. All versions of the REST toolboxes can be freely downloaded at http://www.neuro.uestc.edu.cn/rest/Down.html, and the detailed information including publications, comments and documents on REST can also be found from this website. An example of usage is given with comparative results of REST and average reference. We hope these user-friendly REST toolboxes could make the relatively novel technique of REST easier to study, especially for applications in various EEG studies.

  3. Catalog of NBS standard reference materials, 1975--76 edition. Special pub

    International Nuclear Information System (INIS)

    Seward, R.W.

    1975-06-01

    This Catalog lists and describes the Standard Reference Materials (SRM's), Research Materials (RM's), and General Materials (GM's) currently distributed by the National Bureau of Standards, as well as many of the materials currently in preparation. SRM's are used to calibrate measurement systems and to provide a central basis for uniformity and accuracy of measurement. The unit and quantity, the type, and the certified characterization are listed for each SRM, as well as directions for ordering. The RM's are not certified, but are issued to meet the needs of scientists engaged in materials research. RM's are issued with a 'Report of Investigation', the sole authority of which is the author of the report. The GM's are standardized by some agency other than NBS. NBS acts only as a distribution point and does not participate in the standardization of these materials. Announcements of new and renewal SRM's, RM's and GM's are made in the semi-annual supplements of this Catalog, SRM Price List, and in scientific and trade journals

  4. 12 CFR 1401.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct... INSURANCE CORPORATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1401.1 Cross-references to employee ethical... the Farm Credit System Insurance Corporation are subject to the Standards of Ethical Conduct for...

  5. 22 CFR 1100.1 - Cross-references to employee ethical conduct standards, financial disclosure and financial...

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... STATES SECTION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1100.1 Cross-references to employee ethical... executive branch standards of ethical conduct contained in 5 CFR part 2635, the executive branch financial...

  6. A Framework for Establishing Standard Reference Scale of Texture by Multivariate Statistical Analysis Based on Instrumental Measurement and Sensory Evaluation.

    Science.gov (United States)

    Zhi, Ruicong; Zhao, Lei; Xie, Nan; Wang, Houyin; Shi, Bolin; Shi, Jingye

    2016-01-13

    A framework of establishing standard reference scale (texture) is proposed by multivariate statistical analysis according to instrumental measurement and sensory evaluation. Multivariate statistical analysis is conducted to rapidly select typical reference samples with characteristics of universality, representativeness, stability, substitutability, and traceability. The reasonableness of the framework method is verified by establishing standard reference scale of texture attribute (hardness) with Chinese well-known food. More than 100 food products in 16 categories were tested using instrumental measurement (TPA test), and the result was analyzed with clustering analysis, principal component analysis, relative standard deviation, and analysis of variance. As a result, nine kinds of foods were determined to construct the hardness standard reference scale. The results indicate that the regression coefficient between the estimated sensory value and the instrumentally measured value is significant (R(2) = 0.9765), which fits well with Stevens's theory. The research provides reliable a theoretical basis and practical guide for quantitative standard reference scale establishment on food texture characteristics.

  7. New Search Space Reduction Algorithm for Vertical Reference Trajectory Optimization

    Directory of Open Access Journals (Sweden)

    Alejandro MURRIETA-MENDOZA

    2016-06-01

    Full Text Available Burning the fuel required to sustain a given flight releases pollution such as carbon dioxide and nitrogen oxides, and the amount of fuel consumed is also a significant expense for airlines. It is desirable to reduce fuel consumption to reduce both pollution and flight costs. To increase fuel savings in a given flight, one option is to compute the most economical vertical reference trajectory (or flight plan. A deterministic algorithm was developed using a numerical aircraft performance model to determine the most economical vertical flight profile considering take-off weight, flight distance, step climb and weather conditions. This algorithm is based on linear interpolations of the performance model using the Lagrange interpolation method. The algorithm downloads the latest available forecast from Environment Canada according to the departure date and flight coordinates, and calculates the optimal trajectory taking into account the effects of wind and temperature. Techniques to avoid unnecessary calculations are implemented to reduce the computation time. The costs of the reference trajectories proposed by the algorithm are compared with the costs of the reference trajectories proposed by a commercial flight management system using the fuel consumption estimated by the FlightSim® simulator made by Presagis®.

  8. 22 CFR 1504.1 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Cross-references to employee ethical conduct... FOUNDATION EMPLOYEE RESPONSIBILITIES AND CONDUCT § 1504.1 Cross-references to employee ethical conduct... Foundation are subject to the Standards of Ethical Conduct for Employees of the Executive Branch at 5 CFR...

  9. 41 CFR 105-735.1 - Cross-references to employee ethical conduct standards, financial disclosure regulations, and...

    Science.gov (United States)

    2010-07-01

    ... employee ethical conduct standards, financial disclosure regulations, and other regulations. 105-735.1... CONDUCT § 105-735.1 Cross-references to employee ethical conduct standards, financial disclosure... executive branch-wide standards of ethical conduct at 5 CFR part 2635, GSA's regulations at 5 CFR part 6701...

  10. Development of saw palmetto (Serenoa repens) fruit and extract standard reference materials.

    Science.gov (United States)

    Schantz, Michele M; Bedner, Mary; Long, Stephen E; Molloy, John L; Murphy, Karen E; Porter, Barbara J; Putzbach, Karsten; Rimmer, Catherine A; Sander, Lane C; Sharpless, Katherine E; Thomas, Jeanice B; Wise, Stephen A; Wood, Laura J; Yen, James H; Yarita, Takashi; NguyenPho, Agnes; Sorenson, Wendy R; Betz, Joseph M

    2008-10-01

    As part of a collaboration with the National Institutes of Health's Office of Dietary Supplements and the Food and Drug Administration's Center for Drug Evaluation and Research, the National Institute of Standards and Technology has developed two standard reference materials (SRMs) representing different forms of saw palmetto (Serenoa repens), SRM 3250 Serenoa repens fruit and SRM 3251 Serenoa repens extract. Both of these SRMs have been characterized for their fatty acid and phytosterol content. The fatty acid concentration values are based on results from gas chromatography with flame ionization detection (GC-FID) and mass spectrometry (GC/MS) analysis while the sterol concentration values are based on results from GC-FID and liquid chromatography with mass spectrometry analysis. In addition, SRM 3250 has been characterized for lead content, and SRM 3251 has been characterized for the content of beta-carotene and tocopherols. SRM 3250 (fruit) has certified concentration values for three phytosterols, 14 fatty acids as triglycerides, and lead along with reference concentration values for four fatty acids as triglycerides and 16 free fatty acids. SRM 3251 (extract) has certified concentration values for three phytosterols, 17 fatty acids as triglycerides, beta-carotene, and gamma-tocopherol along with reference concentration values for three fatty acids as triglycerides, 17 fatty acids as free fatty acids, beta-carotene isomers, and delta-tocopherol and information values for two phytosterols. These SRMs will complement other reference materials currently available with concentrations for similar analytes and are part of a series of SRMs being developed for dietary supplements.

  11. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

    Directory of Open Access Journals (Sweden)

    Helen L Storey

    Full Text Available Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates.

  12. Agreement between diagnoses reached by clinical examination and available reference standards: a prospective study of 216 patients with lumbopelvic pain

    Directory of Open Access Journals (Sweden)

    Tropp Hans

    2005-06-01

    Full Text Available Abstract Background The tissue origin of low back pain (LBP or referred lower extremity symptoms (LES may be identified in about 70% of cases using advanced imaging, discography and facet or sacroiliac joint blocks. These techniques are invasive and availability varies. A clinical examination is non-invasive and widely available but its validity is questioned. Diagnostic studies usually examine single tests in relation to single reference standards, yet in clinical practice, clinicians use multiple tests and select from a range of possible diagnoses. There is a need for studies that evaluate the diagnostic performance of clinical diagnoses against available reference standards. Methods We compared blinded clinical diagnoses with diagnoses based on available reference standards for known causes of LBP or LES such as discography, facet, sacroiliac or hip joint blocks, epidurals injections, advanced imaging studies or any combination of these tests. A prospective, blinded validity design was employed. Physiotherapists examined consecutive patients with chronic lumbopelvic pain and/or referred LES scheduled to receive the reference standard examinations. When diagnoses were in complete agreement regardless of complexity, "exact" agreement was recorded. When the clinical diagnosis was included within the reference standard diagnoses, "clinical agreement" was recorded. The proportional chance criterion (PCC statistic was used to estimate agreement on multiple diagnostic possibilities because it accounts for the prevalence of individual categories in the sample. The kappa statistic was used to estimate agreement on six pathoanatomic diagnoses. Results In a sample of chronic LBP patients (n = 216 with high levels of disability and distress, 67% received a patho-anatomic diagnosis based on available reference standards, and 10% had more than one tissue origin of pain identified. For 27 diagnostic categories and combinations, chance clinical agreement

  13. 5 CFR 1900.100 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Cross-references to employee ethical... ethical conduct standards and financial disclosure regulations. Officers and employees of the Appalachian Regional Commission Federal Staff are subject to the Standards of Ethical Conduct for Employees of the...

  14. Optimized Flow Sheet for a Reference Commercial-Scale Nuclear-Driven High-Temperature Electrolysis Hydrogen Production Plant

    International Nuclear Information System (INIS)

    M. G. McKellar; J. E. O'Brien; E. A. Harvego; J. S. Herring

    2007-01-01

    This report presents results from the development and optimization of a reference commercial scale high-temperature electrolysis (HTE) plant for hydrogen production. The reference plant design is driven by a high-temperature helium-cooled reactor coupled to a direct Brayton power cycle. The reference design reactor power is 600 MWt, with a primary system pressure of 7.0 MPa, and reactor inlet and outlet fluid temperatures of 540 C and 900 C, respectively. The electrolysis unit used to produce hydrogen consists of 4.176 - 10 6 cells with a per-cell active area of 225 cm2. A nominal cell area-specific resistance, ASR, value of 0.4 Ohm-cm2 with a current density of 0.25 A/cm2 was used, and isothermal boundary conditions were assumed. The optimized design for the reference hydrogen production plant operates at a system pressure of 5.0 MPa, and utilizes an air-sweep system to remove the excess oxygen that is evolved on the anode side of the electrolyzer. The inlet air for the air-sweep system is compressed to the system operating pressure of 5.0 MPa in a four-stage compressor with intercooling. The overall system thermal-to-hydrogen production efficiency (based on the low heating value of the produced hydrogen) is 49.07% at a hydrogen production rate of 2.45 kg/s with the high-temperature helium-cooled reactor concept. The information presented in this report is intended to establish an optimized design for the reference nuclear-driven HTE hydrogen production plant so that parameters can be compared with other hydrogen production methods and power cycles to evaluate relative performance characteristics and plant economics

  15. 12 CFR 400.101 - Cross-reference to employee financial disclosure and ethical conduct standards regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Cross-reference to employee financial disclosure and ethical conduct standards regulations. 400.101 Section 400.101 Banks and Banking EXPORT-IMPORT.... Employees of the Export-Import Bank of the United States (Bank) should refer to: (a) The executive branch...

  16. The use of high accuracy NAA for the certification of NIST botanical standard reference materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.F.

    1992-01-01

    Neutron activation analysis is one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). NAA competes favorably with all other techniques because of it's unique capabilities for high accuracy even at very low concentrations for many elements. In this paper, instrumental and radiochemical NAA results are described for 25 elements in two new NIST SRMs, SRM 1515 (Apple Leaves) and SRM 1547 (Peach Leaves), and are compared to the certified values for 19 elements in these two new botanical reference materials. (author) 7 refs.; 4 tabs

  17. 5 CFR 1633.1 - Cross-reference to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Cross-reference to employee ethical... ethical conduct standards and financial disclosure regulations. Employees of the Federal Retirement Thrift Investment Board (Board) are subject to the executive branch-wide Standards of Ethical conduct at 5 CFR part...

  18. Quality of Standard Reference Materials for Short Time Activation Analysis

    International Nuclear Information System (INIS)

    Ismail, S.S.; Oberleitner, W.

    2003-01-01

    Some environmental reference materials (CFA-1633 b, IAEA-SL-1, SARM-1,BCR-176, Coal-1635, IAEA-SL-3, BCR-146, and SRAM-5) were analysed by short-time activation analysis. The results show that these materials can be classified in three groups, according to their activities after irradiation. The obtained results were compared in order to create a quality index for determination of short-lived nuclides at high count rates. It was found that Cfta is not a suitable standard for determining very short-lived nuclides (half-lives<1 min) because the activity it produces is 15-fold higher than that SL-3. Biological reference materials, such as SRM-1571, SRM-1573, SRM-1575, SRM-1577, IAEA-392, and IAEA-393, were also investigated by a higher counting efficiency system. The quality of this system and its well-type detector for investigating short-lived nuclides was discussed

  19. Prevention of Crime and the Optimal Standard of Proof in Criminal Law

    DEFF Research Database (Denmark)

    Lando, Henrik

    2003-01-01

    The standard of proof in criminal law a®ects retributive justice throughthe number of wrong convictions and wrong acquittals. It also a®ects thelevel of crime, since a higher standard of proof implies less deterrence andless incapacitation. This article derives an expression for the optimal...

  20. Referring to IAEA system to improve Chinese standards system on nuclear and radiation safety

    International Nuclear Information System (INIS)

    Shang Zhaorong; Wang Wenhai

    2010-01-01

    Referring to the standards system of IAEA, to build and improve the Chinese standards system of nuclear and radiation safety is a long term infrastructure work and an assurance to keep sustainable development of nuclear industry and nuclear technology application in China. The paper analyses the current main problem, and gives some suggestions on developing and improving the system. (authors)

  1. Ad-Hoc vs. Standardized and Optimized Arthropod Diversity Sampling

    Directory of Open Access Journals (Sweden)

    Pedro Cardoso

    2009-09-01

    Full Text Available The use of standardized and optimized protocols has been recently advocated for different arthropod taxa instead of ad-hoc sampling or sampling with protocols defined on a case-by-case basis. We present a comparison of both sampling approaches applied for spiders in a natural area of Portugal. Tests were made to their efficiency, over-collection of common species, singletons proportions, species abundance distributions, average specimen size, average taxonomic distinctness and behavior of richness estimators. The standardized protocol revealed three main advantages: (1 higher efficiency; (2 more reliable estimations of true richness; and (3 meaningful comparisons between undersampled areas.

  2. 12 CFR 601.100 - Cross-references to employee ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Cross-references to employee ethical conduct... employee ethical conduct standards and financial disclosure regulations. Board members, officers, and other employees of the Farm Credit Administration are subject to the Standards of Ethical Conduct for Employees of...

  3. Initial testing of a neutron activation analysis system by analysing standard reference materials

    International Nuclear Information System (INIS)

    Suhaimi Hamzah; Roslan Idris; Abdul Khalik Haji Wood; Che Seman Mahmood; Abdul Rahim Mohamad Noor.

    1983-01-01

    This paper describes the data acquisition and processing system in our laboratories (ND6600), the methods of activation analysis and the results obtained from our analysis of IAEA standard reference material (SL-l lake sediments and NBS coal ash 1632a). These standards were analysed in order to check the capability of the system, which was designed in such a way as to enable the user to independently collect and process data from multiple radiation detectors. (author)

  4. Neutron activation analysis for certification of standard reference materials

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Perez Zayas, G.; Hernandez Rivero, A.; Ribeiro Guevara, S.

    1996-01-01

    Neutron activation analysis is used extensively as one of the analytical techniques in the certification of standard reference materials. Characteristics of neutron activation analysis which make it valuable in this role are: accuracy multielemental capability to asses homogeneity, high sensitivity for many elements, and essentially non-destructive method. This paper report the concentrations of 30 elements (major, minor and trace elements) in four Cuban samples. The samples were irradiated in a thermal neutron flux of 10 12- 10 13 n.cm 2. s -1. The gamma ray spectra were measured by HPGe detectors and were analyzed using ACTAN program development in Center of Applied Studies for Nuclear Development

  5. Certification of standard reference materials employing neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, G.; Hernandez Rivero, A.; Molina Insfran, J.; Ribeiro Guevara, S.; Santana Encinosa, C.; Perez Zayas, G.

    1997-01-01

    Neutron activation analysis (Naa) is used extensively as one of the analytical techniques in the certification of standard reference materials (Srm). Characteristics of Naa which make it valuable in this role are: accuracy; multielemental capability; ability to assess homogeneity; high sensitivity for many elements, and essentially non-destructive method. This paper reports the concentrations of thirty elements (major, minor and trace elements) in four Cuban Srm's. The samples were irradiated in a thermal neutron flux of 10 12 -10 13 neutrons.cm -2 .s -1 . The gamma-ray spectra were measured by HPGe detectors and were analysed using ACTAN program, developed in CEADEN. (author) [es

  6. The Quality Control of Reference Standards in Metrology Dosimetry

    International Nuclear Information System (INIS)

    Lazarevic, Dj.; Ciraj Bjelac, O.; Kovacevic, M.; Vukcevic, M.

    2008-01-01

    This works presents the quality control tests applied to two types of ionization chambers with suitable electrometers. Measuring assemblies were tested in order to assess their performance and adequacy for use as reference standards in ionising radiation metrology laboratory for calibrations in the field of radiotherapy and radiation protection. Two types of ionizing chambers (Farmer type, 0.6 cm 3 and spherical ionizing chamber, 1 l) with suitable electrometers were tested. Following test were performed: repeatability, long term stability, polarity and leakage current measurement. All tested measuring assemblies demonstrated proper performance, correctness and high reliance of measurements, since all implemented quality control test results were within acceptable limits. (author)

  7. Consultation on urological specimens from referred cancer patients using real-time digital microscopy: Optimizing the workflow

    Directory of Open Access Journals (Sweden)

    Henrik Holten-Rossing

    2016-01-01

    Full Text Available Introduction: Centralization of cancer treatment entails a reassessment of the diagnostic tissue specimens. Packaging and shipment of glass slides from the local to the central pathology unit means that the standard procedure is time-consuming and that it is difficult to comply with governmental requirements. The aim was to evaluate whether real-time digital microscopy for urological cancer specimens during the primary diagnostic process can replace subsequent physical slide referral and reassessment without compromising diagnostic safety. Methods: From May to October 2014, tissue specimens from 130 patients with urological cancer received at Næstved Hospital′s Pathology Department, and expected to be referred for further treatment at cancer unit of a university hospital, were diagnosed using standard light microscopy. In the event of diagnostic uncertainty, the VisionTek digital microscope (Sakura Finetek was employed. The Pathology Department at Næstved Hospital was equipped with a digital microscope and three consultant pathologists were stationed at Rigshospitalet with workstations optimized for digital microscopy. Representative slides for each case were selected for consultation and live digital consultation took place over the telephone using remote access software. Time of start and finish for each case was logged. For the physically referred cases, time from arrival to sign-out was logged in the national pathology information system, and time spent on microscopy and reporting was noted manually. Diagnosis, number of involved biopsies, grade, and stage were compared between digital microscopy and conventional microscopy. Results: Complete data were available for all 130 cases. Standard procedure with referral of urological cancer specimens took a mean of 8 min 56 s for microscopy, reporting and sign-out per case. For live digital consultations, a mean of 18 min 37 s was spent on each consultation with 4 min 43 s for each case

  8. Robust Optimal Adaptive Control Method with Large Adaptive Gain

    Science.gov (United States)

    Nguyen, Nhan T.

    2009-01-01

    In the presence of large uncertainties, a control system needs to be able to adapt rapidly to regain performance. Fast adaptation is referred to the implementation of adaptive control with a large adaptive gain to reduce the tracking error rapidly. However, a large adaptive gain can lead to high-frequency oscillations which can adversely affect robustness of an adaptive control law. A new adaptive control modification is presented that can achieve robust adaptation with a large adaptive gain without incurring high-frequency oscillations as with the standard model-reference adaptive control. The modification is based on the minimization of the Y2 norm of the tracking error, which is formulated as an optimal control problem. The optimality condition is used to derive the modification using the gradient method. The optimal control modification results in a stable adaptation and allows a large adaptive gain to be used for better tracking while providing sufficient stability robustness. Simulations were conducted for a damaged generic transport aircraft with both standard adaptive control and the adaptive optimal control modification technique. The results demonstrate the effectiveness of the proposed modification in tracking a reference model while maintaining a sufficient time delay margin.

  9. Neutron activation analysis of reference materials by the k sub 0 standardization and relative methods

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, M C; Martinho, E [LNETI/ICEN, Sacavem (Portugal)

    1989-04-15

    Instrumental neutron activation analysis with the k{sub o}-standardization method was applied to eight geological, environmental and biological reference materials, including leaves, blood, fish, sediments, soils and limestone. To a first approximation, the results were normally distributed around the certified values with a standard deviation of 10%. Results obtained by using the relative method based on well characterized multi-element standards for IAEA CRM Soil-7 are reported.

  10. Calibrating NIST SRM 683 as A New International Reference Standard for Zn Isotopes

    Science.gov (United States)

    Yang, Y.; Zhang, X.; Yu, H.; Huang, F.

    2017-12-01

    Zinc isotopes have been widely applied in the cosmochemical, geochemical, and environmental studies (Moynier et al. 2017). Obtaining precise Zn isotopic data for inter-laboratory comparison is a prerequisite to these applications. Currently, the JMC3-0749L is the primary reference standard for Zn isotopes (Albarède 2004), but it is not commercially available now. Thus, it is necessary to calibrate a new international primary reference standard for Zn isotopic analysis. Chen et al. (2016) showed that NIST SRM 683 (a pure Zn metal nugget of 140 grams) has a δ66ZnJMC of 0.12‰, which is falling within the range of natural Zn isotopic compositions, and it may a good candidate for the next generation of international reference standard (Chen et al. 2016). In order to further examine whether NIST SRM 683 has a homogeneous Zn isotopic composition, we measured more NIST SRM 683 by double-spike methods using MC-ICPMS (Conway et al. 2013). The metal nuggets of NIST SRM 683 were intensively sampled by micro-drilling. Zinc isotope analyses for two nuggets show that they have δ66Zn of 0.14 ± 0.02‰ (2SD, N = 32) and 0.13 ± 0.02‰ (2SD, N = 33), respectively. These values are similar to those of two Zn metal nuggets (0.11 ± 0.02‰ vs. 0.12 ± 0.02‰) reported previously by Chen et al. (2016). We fully dissolved one nugget, producing pure Zn solution with identical Zn isotopic composition with the drilling samples. All results strongly support that NIST SRM 683 is homogeneous in Zn isotopic compositions which could be an ideal candidate for the next reference for Zn isotopes. Tests on more metal nuggets will be performed in a few months for further confirming the Zn isotope compositions and homogeneity. Reference: Albarède et al., 2004. 'The stable isotope geochemistry of copper and zinc', Reviews in Mineralogy and Geochemistry, 55: 409-27. Chen et al., 2016. 'Zinc Isotopic Compositions of NIST SRM 683 and Whole-Rock Reference Materials', Geostandards and

  11. International Longitudinal Paediatric Reference Standards for Bone Mineral Content

    Science.gov (United States)

    Baxter-Jones, Adam DG; McKay, Heather; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don

    2014-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women’s Health Study (n=112) and Stanford’s Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement in predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (P accrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. Similar findings were found for PF and FN. Female models for all sites were similar with age, height and weight all independent significant predictors of BMC accrual (P accounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in paediatrics we recommend standards that are sex, age, size and ethnic specific. PMID:19854308

  12. International longitudinal pediatric reference standards for bone mineral content.

    Science.gov (United States)

    Baxter-Jones, Adam D G; Burrows, Melonie; Bachrach, Laura K; Lloyd, Tom; Petit, Moira; Macdonald, Heather; Mirwald, Robert L; Bailey, Don; McKay, Heather

    2010-01-01

    To render a diagnosis pediatricians rely upon reference standards for bone mineral density or bone mineral content, which are based on cross-sectional data from a relatively small sample of children. These standards are unable to adequately represent growth in a diverse pediatric population. Thus, the goal of this study was to develop sex and site-specific standards for BMC using longitudinal data collected from four international sites in Canada and the United States. Data from four studies were combined; Saskatchewan Paediatric Bone Mineral Accrual Study (n=251), UBC Healthy Bones Study (n=382); Penn State Young Women's Health Study (n=112) and Stanford's Bone Mineral Accretion study (n=423). Males and females (8 to 25 years) were measured for whole body (WB), total proximal femur (PF), femoral neck (FN) and lumbar spine (LS) BMC (g). Data were analyzed using random effects models. Bland-Altman was used to investigate agreement between predicted and actual data. Age, height, weight and ethnicity independently predicted BMC accrual across sites (Paccrual; Hispanic 75.4 (28.2) g less BMC accrual; Blacks 82.8 (26.3) g more BMC accrual with confounders of age, height and weight controlled. We report similar findings for the PF and FN. Models for females for all sites were similar with age, height and weight as independent significant predictors of BMC accrual (Paccounting for age, size, sex and ethnicity. In conclusion, when interpreting BMC in pediatrics we recommend standards that are sex, age, size and ethnic specific. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  13. Standard reference material certification: contribution of NAA with a TRIGA reactor

    International Nuclear Information System (INIS)

    Orvini, E.; Speziali, M.; Salvini, A.; Herborg, C.

    2002-01-01

    Pavia has cooperative links with the major international agencies devoted to the certification of SRMs or CRMs as the Bureau Communautaire de Reference (BCR), the European Institute for Reference Materials and Measurement (IRMM), the USA National Institute of Standards and Technology (NIST) and the International Atomic Energy Agency (IAEA). During these cooperative works, a large amount of analytical data obtained with NAA has been compared, and meaningful methodological information achieved with respect to accuracy and precision in the analysis of several elements at different concentrations in various matrices. Analytical data on As, Cd, Cr, Co, Cu, Cs, Fe, Zn, K, Sc, U, Th, Al, Sb, Mn, V, Hg, Sr, Rb, Se,Pt, all the Rare Earths and halogens Br, Cl, I, have been obtained and contributed for the final certification

  14. Solving non-standard packing problems by global optimization and heuristics

    CERN Document Server

    Fasano, Giorgio

    2014-01-01

    This book results from a long-term research effort aimed at tackling complex non-standard packing issues which arise in space engineering. The main research objective is to optimize cargo loading and arrangement, in compliance with a set of stringent rules. Complicated geometrical aspects are also taken into account, in addition to balancing conditions based on attitude control specifications. Chapter 1 introduces the class of non-standard packing problems studied. Chapter 2 gives a detailed explanation of a general model for the orthogonal packing of tetris-like items in a convex domain. A number of additional conditions are looked at in depth, including the prefixed orientation of subsets of items, the presence of unusable holes, separation planes and structural elements, relative distance bounds as well as static and dynamic balancing requirements. The relative feasibility sub-problem which is a special case that does not have an optimization criterion is discussed in Chapter 3. This setting can be exploit...

  15. Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method covers an experimental procedure for checking experimental technique and instrumentation. If followed, this test method will provide repeatable potentiostatic and potentiodynamic anodic polarization measurements that will reproduce data determined by others at other times and in other laboratories provided all laboratories are testing reference samples from the same lot of Type 430 stainless steel. 1.2 Values stated in SI units are to be regarded as the standard. Inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  16. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  17. Japanese tea leaves: a possible biological standard reference material

    International Nuclear Information System (INIS)

    Fuwa, Keiichiro; Notsu, Kenji; Tsunoda, Kin-ichi; Kato, Hideaki; Yamamoto, Yuko.

    1978-01-01

    Japanese Tea Leaves, prepared by pulverizing with an agate ball mill and sieving with a Saran fiber sieve (50 mesh) were assessed as a possible biological standard reference material for elemental analysis. The metal content of the tea leaves was determined independently at two laboratories using atomic absorption and flame emission spectrometry. Neutron activation analysis was also performed to determine the content (21 elements) of Tea Leaves. For some elements the result from the various methods were compared. The characteristics of Tea Leaves are discussed and the elemental composition is compared to that of Orchard Leaves (NBS SRM, 1571). The most significant characteristic of Tea Leaves was the high manganese content. (auth.)

  18. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    Directory of Open Access Journals (Sweden)

    Azmil Haizam Ahmad Tarmizi

    2008-01-01

    Full Text Available This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 ° C in palm oil, 22.7 ± 0.4 ° C in palm olein and 53.4 ± 0.2 ° C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of -20 ° C, 0 ° C, 6 ° C and 24 ° C upon storage for one year.

  19. Palm-Based Standard Reference Materials for Iodine Value and Slip Melting Point

    Directory of Open Access Journals (Sweden)

    Azmil Haizam Ahmad Tarmizi

    2008-01-01

    Full Text Available This work described study protocols on the production of Palm-Based Standard Reference Materials for iodine value and slip melting point. Thirty-three laboratories collaborated in the inter-laboratory proficiency tests for characterization of iodine value, while thirty-two laboratories for characterization of slip melting point. The iodine value and slip melting point of palm oil, palm olein and palm stearin were determined in accordance to MPOB Test Methods p3.2:2004 and p4.2:2004, respectively. The consensus values and their uncertainties were based on the acceptability of statistical agreement of results obtained from collaborating laboratories. The consensus values and uncertainties for iodine values were 52.63 ± 0.14 Wijs in palm oil, 56.77 ± 0.12 Wijs in palm olein and 33.76 ± 0.18 Wijs in palm stearin. For the slip melting points, the consensus values and uncertainties were 35.6 ± 0.3 °C in palm oil, 22.7 ± 0.4 °C in palm olein and 53.4 ± 0.2 °C in palm stearin. Repeatability and reproducibility relative standard deviations were found to be good and acceptable, with values much lower than that of 10%. Stability of Palm-Based Standard Reference Materials remained stable at temperatures of –20 °C, 0 °C, 6 °C and 24 °C upon storage for one year.

  20. Optimal synthesis and operation of advanced energy supply systems for standard and domotic home

    International Nuclear Information System (INIS)

    Buoro, Dario; Casisi, Melchiorre; Pinamonti, Piero; Reini, Mauro

    2012-01-01

    Highlights: ► Definition of an optimization model for a home energy supply system. ► Optimization of the energy supply system for standard and domotic home. ► Strong improvement can be achieved adopting the optimal system in standard and domotic home. ► The improvements are consistent if supply side and demand side strategies are applied together. ► Solutions with internal combustion engines are less sensible to market price of electricity and gas. - Abstract: The paper deals with the optimization of an advanced energy supply systems for two dwellings: a standard home and an advanced domotic home, where some demand side energy saving strategies have been implemented. In both cases the optimal synthesis, design and operation of the whole energy supply system have been obtained and a sensitivity analysis has been performed, by introducing different economic constraints. The optimization model is based on a Mixed Integer Linear Program (MILP) and includes different kinds of small-scale cogenerators, geothermal heat pumps, boilers, heat storages, solar thermal and photovoltaic panels. In addition, absorption machines, supplied with cogenerated heat, can be used instead of conventional electrical chiller to face the cooling demand. The aim of the analysis is to address the question if advanced demand strategies and supply strategies have to be regarded as alternatives, or if they have to be simultaneously applied, in order to obtain the maximum energy and economic benefit.

  1. Reference values assessment in a Mediterranean population for small dense low-density lipoprotein concentration isolated by an optimized precipitation method

    Directory of Open Access Journals (Sweden)

    Fernández-Cidón B

    2017-06-01

    Full Text Available Bárbara Fernández-Cidón,1–3 Ariadna Padró-Miquel,1 Pedro Alía-Ramos,1 María José Castro-Castro,1 Marta Fanlo-Maresma,4 Dolors Dot-Bach,1 José Valero-Politi,1 Xavier Pintó-Sala,4 Beatriz Candás-Estébanez1 1Clinical Laboratory, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, Spain; 2Department of Biochemistry, Molecular Biology and Biomedicine, Autonomous University of Barcelona (UAB, Barcelona, Spain; 3Department of Pharmacotherapy, Pharmacogenetics and Pharmaceutical Technology, Institut d’Investigació Biomèdica de Bellvitge (IDIBELL, L’Hospitalet de Llobregat, Spain; 4Cardiovascular Risk Unit, Hospital Universitari de Bellvitge, L’Hospitalet de Llobregat, Spain Background: High serum concentrations of small dense low-density lipoprotein cholesterol (sd-LDL-c particles are associated with risk of cardiovascular disease (CVD. Their clinical application has been hindered as a consequence of the laborious current method used for their quantification. Objective: Optimize a simple and fast precipitation method to isolate sd-LDL particles and establish a reference interval in a Mediterranean population. Materials and methods: Forty-five serum samples were collected, and sd-LDL particles were isolated using a modified heparin-Mg2+ precipitation method. sd-LDL-c concentration was calculated by subtracting high-density lipoprotein cholesterol (HDL-c from the total cholesterol measured in the supernatant. This method was compared with the reference method (ultracentrifugation. Reference values were estimated according to the Clinical and Laboratory Standards Institute and The International Federation of Clinical Chemistry and Laboratory Medicine recommendations. sd-LDL-c concentration was measured in serums from 79 subjects with no lipid metabolism abnormalities. Results: The Passing–Bablok regression equation is y = 1.52 (0.72 to 1.73 + 0.07x (−0.1 to 0.13, demonstrating no significant statistical differences

  2. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    Science.gov (United States)

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  3. Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS.

    Science.gov (United States)

    Creech, J B; Baker, J A; Handler, M R; Bizzarro, M

    2014-01-10

    We report a method for the chemical purification of Pt from geological materials by ion-exchange chromatography for subsequent Pt stable isotope analysis by multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) using a 196 Pt- 198 Pt double-spike to correct for instrumental mass bias. Double-spiking of samples was carried out prior to digestion and chemical separation to correct for any mass-dependent fractionation that may occur due to incomplete recovery of Pt. Samples were digested using a NiS fire assay method, which pre-concentrates Pt into a metallic bead that is readily dissolved in acid in preparation for anion-exchange chemistry. Pt was recovered from anion-exchange resin in concentrated HNO 3 acid after elution of matrix elements, including the other platinum group elements (PGE), in dilute HCl and HNO 3 acids. The separation method has been calibrated using a precious metal standard solution doped with a range of synthetic matrices and results in Pt yields of ≥90% with purity of ≥95%. Using this chemical separation technique, we have separated Pt from 11 international geological standard reference materials comprising of PGE ores, mantle rocks, igneous rocks and one sample from the Cretaceous-Paleogene boundary layer. Pt concentrations in these samples range from ca. 5 ng g -1 to 4 μg g -1 . This analytical method has been shown to have an external reproducibility on δ 198 Pt (permil difference in the 198 Pt/ 194 Pt ratio from the IRMM-010 standard) of ±0.040 (2 sd) on Pt solution standards (Creech et al., 2013, J. Anal. At. Spectrom. 28, 853-865). The reproducibility in natural samples is evaluated by processing multiple replicates of four standard reference materials, and is conservatively taken to be ca. ±0.088 (2 sd). Pt stable isotope data for the full set of reference materials have a range of δ 198 Pt values with offsets of up to 0.4‰ from the IRMM-010 standard, which are readily resolved with this technique. These

  4. Reference standard for serum bile acids in pregnancy.

    LENUS (Irish Health Repository)

    2012-01-31

    Please cite this paper as: Egan N, Bartels A, Khashan A, Broadhurst D, Joyce C, O\\'Mullane J, O\\'Donoghue K. Reference standard for serum bile acids in pregnancy. BJOG 2012;00:000-000. DOI: 10.1111\\/j.1471-0528.2011.03245.x. Objective Obstetric cholestasis (OC) is a liver disorder characterised by pruritus and elevated serum bile acids (SBA) that affects one in 200 pregnant women. It is associated with adverse perinatal outcomes such as premature delivery and stillbirth. Mild OC is defined as SBA levels of 10-39 mumol\\/l, and severe OC is defined by levels >40 mumol\\/l. SBA levels in normal pregnancy have not been investigated. We aimed to establish reference values for SBA in healthy pregnant women across different trimesters of pregnancy. Design Cross-sectional analysis of SBA levels. Setting A large tertiary referral university teaching maternity hospital. Population Healthy pregnant women with a singleton pregnancy and a body mass index (BMI) < 40, excluding women with significant alcohol intake, history of liver disease, prior cholecystectomy and OC. Methods Cross-sectional analysis of SBA levels at 12, 20, 28 and 36 weeks of gestation, and on days 1-3 postpartum. Main outcome measures SBA levels in mumol\\/l. Results A total of 219 women attending for antenatal care were recruited, and SBA levels were assayed at 12, 20, 28 and 36 weeks of gestation, and up to 72 hours postpartum (n = 44-49 cases at each stage). The majority were white European women, with a median age of 30 years (range 17-46 years) and median BMI of 25 (range 18-38). Values of SBA ranged from 0.3 to 9.8 mumol\\/l in 216 women, with only three measurements outside this range. There were no significant changes throughout pregnancy. Conclusions SBA values in uncomplicated pregnancies are consistent, regardless of gestation, and are not elevated in pregnancy. The current reference values for the diagnosis of OC appear to be appropriate.

  5. 29 CFR 0.735-1 - Cross-references to employee ethical conduct standards, financial disclosure regulations and...

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Cross-references to employee ethical conduct standards, financial disclosure regulations and other ethics regulations. 0.735-1 Section 0.735-1 Labor Office of the Secretary of Labor ETHICS AND CONDUCT OF DEPARTMENT OF LABOR EMPLOYEES Standards of Conduct for Current...

  6. Application of diagnostic reference levels in medical practice

    Energy Technology Data Exchange (ETDEWEB)

    Bourguignon, Michel [Faculty of Medicine of Paris, Deputy Director General, Nuclear Safety Authority (ASN), Paris (France)

    2006-07-01

    Diagnosis reference levels (D.R.L.) are defined in the Council Directive 97/43 EURATOM as 'Dose levels in medical radio diagnosis practices or in the case of radiopharmaceuticals, levels of activity, for typical examinations for groups of standards-sized patients or standards phantoms for broadly defined types of equipment. These levels are expected not to be exceeded for standard procedures when good and normal practice regarding diagnostic and technical performance is applied'. Thus D.R.L. apply only to diagnostic procedures and does not apply to radiotherapy. Radiation protection of patients is based on the application of 2 major radiation protection principles, justification and optimization. The justification principle must be respected first because the best way to protect the patient is not to carry a useless test. Radiation protection of the patient is a continuous process and local dose indicator values in the good range should not prevent the radiologist or nuclear medicine physician to continue to optimize their practice. (N.C.)

  7. Application of diagnostic reference levels in medical practice

    International Nuclear Information System (INIS)

    Bourguignon, Michel

    2006-01-01

    Diagnosis reference levels (D.R.L.) are defined in the Council Directive 97/43 EURATOM as 'Dose levels in medical radio diagnosis practices or in the case of radiopharmaceuticals, levels of activity, for typical examinations for groups of standards-sized patients or standards phantoms for broadly defined types of equipment. These levels are expected not to be exceeded for standard procedures when good and normal practice regarding diagnostic and technical performance is applied'. Thus D.R.L. apply only to diagnostic procedures and does not apply to radiotherapy. Radiation protection of patients is based on the application of 2 major radiation protection principles, justification and optimization. The justification principle must be respected first because the best way to protect the patient is not to carry a useless test. Radiation protection of the patient is a continuous process and local dose indicator values in the good range should not prevent the radiologist or nuclear medicine physician to continue to optimize their practice. (N.C.)

  8. Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure for the determination of a spectral mismatch parameter used in performance testing of photovoltaic devices. 1.2 The spectral mismatch parameter is a measure of the error, introduced in the testing of a photovoltaic device, caused by mismatch between the spectral responses of the photovoltaic device and the photovoltaic reference cell, as well as mismatch between the test light source and the reference spectral irradiance distribution to which the photovoltaic reference cell was calibrated. Examples of reference spectral irradiance distributions are Tables E490 or G173. 1.3 The spectral mismatch parameter can be used to correct photovoltaic performance data for spectral mismatch error. 1.4 This test method is intended for use with linear photovoltaic devices. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, a...

  9. NASA/NBS (National Aeronautics and Space Administration/National Bureau of Standards) standard reference model for telerobot control system architecture (NASREM)

    Science.gov (United States)

    Albus, James S.; Mccain, Harry G.; Lumia, Ronald

    1989-01-01

    The document describes the NASA Standard Reference Model (NASREM) Architecture for the Space Station Telerobot Control System. It defines the functional requirements and high level specifications of the control system for the NASA space Station document for the functional specification, and a guideline for the development of the control system architecture, of the 10C Flight Telerobot Servicer. The NASREM telerobot control system architecture defines a set of standard modules and interfaces which facilitates software design, development, validation, and test, and make possible the integration of telerobotics software from a wide variety of sources. Standard interfaces also provide the software hooks necessary to incrementally upgrade future Flight Telerobot Systems as new capabilities develop in computer science, robotics, and autonomous system control.

  10. Optimization of Saanen sperm genes amplification: evaluation of standardized protocols in genetically uncharacterized rural goats reared under a subtropical environment.

    Science.gov (United States)

    Barbour, Elie K; Saade, Maya F; Sleiman, Fawwak T; Hamadeh, Shady K; Mouneimne, Youssef; Kassaifi, Zeina; Kayali, Ghazi; Harakeh, Steve; Jaber, Lina S; Shaib, Houssam A

    2012-10-01

    The purpose of this research is to optimize quantitatively the amplification of specific sperm genes in reference genomically characterized Saanen goat and to evaluate the standardized protocols applicability on sperms of uncharacterized genome of rural goats reared under subtropical environment for inclusion in future selection programs. The optimization of the protocols in Saanen sperms included three production genes (growth hormone (GH) exons 2, 3, and 4, αS1-casein (CSN1S1), and α-lactalbumin) and two health genes (MHC class II DRB and prion (PrP)). The optimization was based on varying the primers concentrations and the inclusion of a PCR cosolvent (Triton X). The impact of the studied variables on statistically significant increase in the yield of amplicons was noticed in four out of five (80%) optimized protocols, namely in those related to GH, CSN1S1, α-lactalbumin, and PrP genes (P 0.05). The applicability of the optimized protocols of Saanen sperm genes on amplification of uncharacterized rural goat sperms revealed a 100% success in tested individuals for amplification of GH, CSN1S1, α-lactalbumin, and MHC class II DRB genes and a 75% success for the PrP gene. The significant success in applicability of the Saanen quantitatively optimized protocols to other uncharacterized genome of rural goats allows for their inclusion in future selection, targeting the sustainability of this farming system in a subtropical environment and the improvement of the farmers livelihood.

  11. Universal Reference RNA as a standard for microarray experiments

    Directory of Open Access Journals (Sweden)

    Fero Michael

    2004-03-01

    Full Text Available Abstract Background Obtaining reliable and reproducible two-color microarray gene expression data is critically important for understanding the biological significance of perturbations made on a cellular system. Microarray design, RNA preparation and labeling, hybridization conditions and data acquisition and analysis are variables difficult to simultaneously control. A useful tool for monitoring and controlling intra- and inter-experimental variation is Universal Reference RNA (URR, developed with the goal of providing hybridization signal at each microarray probe location (spot. Measuring signal at each spot as the ratio of experimental RNA to reference RNA targets, rather than relying on absolute signal intensity, decreases variability by normalizing signal output in any two-color hybridization experiment. Results Human, mouse and rat URR (UHRR, UMRR and URRR, respectively were prepared from pools of RNA derived from individual cell lines representing different tissues. A variety of microarrays were used to determine percentage of spots hybridizing with URR and producing signal above a user defined threshold (microarray coverage. Microarray coverage was consistently greater than 80% for all arrays tested. We confirmed that individual cell lines contribute their own unique set of genes to URR, arguing for a pool of RNA from several cell lines as a better configuration for URR as opposed to a single cell line source for URR. Microarray coverage comparing two separately prepared batches each of UHRR, UMRR and URRR were highly correlated (Pearson's correlation coefficients of 0.97. Conclusion Results of this study demonstrate that large quantities of pooled RNA from individual cell lines are reproducibly prepared and possess diverse gene representation. This type of reference provides a standard for reducing variation in microarray experiments and allows more reliable comparison of gene expression data within and between experiments and

  12. Mobility-based Time References for Wireless Sensor Networks

    CERN Document Server

    Sebastiano, Fabio; Makinwa, Kofi A A

    2013-01-01

     This book describes the use of low-power low-cost and extremely small radios to provide essential time reference for wireless sensor networks.  The authors explain how to integrate such radios in a standard CMOS process to reduce both cost and size, while focusing on the challenge of designing a fully integrated time reference for such radios. To enable the integration of the time reference, system techniques are proposed and analyzed, several kinds of integrated time references are reviewed, and mobility-based references are identified as viable candidates to provide the required accuracy at low-power consumption. Practical implementations of a mobility-based oscillator and a temperature sensor are also presented, which demonstrate the required accuracy over a wide temperature range, while drawing 51-uW from a 1.2-V supply in a 65-nm CMOS process. Provides system analysis to understand requirements for time/frequency accuracy in wireless sensor networks; Describes system optimization for time references i...

  13. Stability of Working Reference Standards for Hybrid K-Edge Densitometer Quality Assurance

    International Nuclear Information System (INIS)

    Guzzardo, T.; Pickett, C.A.; McElroy, R.; Croft, S.; Garrison, J.; Venkataraman, R.

    2015-01-01

    The relatively short working life of aqueous solution standards of actinides for the calibration and quality control of Hybrid K-Edge Densitometer (HKED) measurements necessitates the development of a stable matrix material less susceptible to degradation. Degradation in the form of evaporation, radiolysis, settling, sloshing, and sediment formation can all reduce the reliability and working life of an aqueous standard. These factors make aqueous solutions inadequate for long-term quality assurance measurements designed to detect weak or subtle trends in system performance. Epoxy, studied here, is an alternative matrix material that may be less vulnerable to degradation. An additional benefit of epoxy is that standards can easily be characterized as sealed sources which allows for simplified administrative controls during shipping and storage. The stability of working reference standards consisting of U 3 O 8 in an epoxy matrix for use in the HKED has been tracked for over three years through repeated X-ray Fluorescence (XRF) and K-Edge (KED) measurements. A set of six epoxy standards ranging in concentration from 1 g/l to 76 g/l uranium were determined to be stable, within the expected accuracy of the system, over the period of analysis. During this time, no effort was made to enhance the stability of the epoxy standards; the radial measurement position was not controlled and in the middle of the analysis period the HKED system and standards were shipped from the vendor's factory to the customer. Epoxy standards afford numerous benefits over those created from aqueous solutions and should be considered when developing HKED standards for quality assurance measurements. The stability of the epoxy allows the development of working standards of a stability and robustness sufficient for use in a proposed international round-robin exercise based on the exchange of such standards. (author)

  14. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    Science.gov (United States)

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  15. New reference charts for testicular volume in Dutch children and adolescents allow the calculation of standard deviation scores

    NARCIS (Netherlands)

    Joustra, S.D.; Plas, E.M. van der; Goede, J.; Oostdijk, W.; Delemarre-van de Waal, H.A.; Hack, W.W.M.; Buuren, S. van; Wit, J.M.

    2015-01-01

    Aim Accurate calculations of testicular volume standard deviation (SD) scores are not currently available. We constructed LMS-smoothed age-reference charts for testicular volume in healthy boys. Methods The LMS method was used to calculate reference data, based on testicular volumes from

  16. STL pocket reference

    CERN Document Server

    Lischner, Ray

    2003-01-01

    The STL Pocket Reference describes the functions, classes, and templates in that part of the C++ standard library often referred to as the Standard Template Library (STL). The STL encompasses containers, iterators, algorithms, and function objects, which collectively represent one of the most important and widely used subsets of standard library functionality. The C++ standard library, even the subset known as the STL, is vast. It's next to impossible to work with the STL without some sort of reference at your side to remind you of template parameters, function invocations, return types--ind

  17. Standardization of reference radiation field of beta for 85Kr using extrapolation chamber

    International Nuclear Information System (INIS)

    Nazaroh; Fendinugroho

    2013-01-01

    Standardization of reference radiation field of beta for 85 Kr in PTKMR-BATAN Laboratory has been performed at the SDD's 30 cm by using extrapolation chamber detector, coupled with Uni dose electrometer. The result was : (8.98±3 %) mGy/h, at 95 % confidence level. The aim of standardization of reference radiation field is to support radiation protection and safety program, provided by the International Atomic Energy Agency to its Member States, included BATAN-Indonesia, especially, PTKMR. The aim of radiation protection program and safety program is to promote an internationally harmonized approach for radiation measurement in protection level, besides for calibration of radiation measuring instrument, which users spread across Indonesia, with the number of about 795 firms in the year of 2012. These benefits can be felt by workers, communities and the environment, because by calibration, measurement survey meter, pocket dosimeter and TLD to be more accurate so that the radiation dose received by radiation workers is accurate and can be ascertained in a specified period, not to exceed a predetermined NBD by BAPETEN. The aim of this calibration is appropriate with the primary objective of calibration on IAEA/TRS16:2000. (author)

  18. ['Gold standard', not 'golden standard'

    NARCIS (Netherlands)

    Claassen, J.A.H.R.

    2005-01-01

    In medical literature, both 'gold standard' and 'golden standard' are employed to describe a reference test used for comparison with a novel method. The term 'gold standard' in its current sense in medical research was coined by Rudd in 1979, in reference to the monetary gold standard. In the same

  19. Standard reference data for the air-liquid and vapor-liquid surface tension of benzene

    Czech Academy of Sciences Publication Activity Database

    Součková, Monika; Klomfar, Jaroslav; Pátek, Jaroslav

    2013-01-01

    Roč. 356, October (2013), s. 329-337 ISSN 0378-3812 R&D Projects: GA ČR GA101/09/0010 Institutional support: RVO:61388998 Keywords : benzene * surface tension * experimental data * standard reference data Subject RIV: BJ - Thermodynamics Impact factor: 2.241, year: 2013 http://www.sciencedirect.com/science/article/pii/S0378381213004196

  20. Construction of a new growth references for China based on urban Chinese children: comparison with the WHO growth standards.

    Science.gov (United States)

    Zong, Xin-Nan; Li, Hui

    2013-01-01

    Growth references for Chinese children should be updated due to the positive secular growth trends and the progress of the smoothing techniques. Human growth differs among the various ethnic groups, so comparison of the China references with the WHO standards helps to understand such differences. The China references, including weight, length/height, head circumference, weight-for-length/height and body mass index (BMI) aged 0-18 years, were constructed based on 69,760 urban infants and preschool children under 7 years and 24,542 urban school children aged 6-20 years derived from two cross-sectional national surveys. The Cole's LMS method is employed for smoothing the growth curves. The merged data sets resulted in a smooth transition at age 6-7 years and continuity of curves from 0 to 18 years. Varying differences were found on the empirical standard deviation (SD) curves in each indicator at nearly all ages between China and WHO. The most noticeable differences occurred in genders, final height and boundary centiles curves. Chinese boys' weight is strikingly heavier than that of the WHO at age 6-10 years. The height is taller than that of the WHO for boys below 15 years and for girls below 13, but is significantly lower when boys over 15 years and girls over 13. BMI is generally higher than that of the WHO for boys at age 6-16 years but appreciably lower for girls at 3-18 years. The differences between China and WHO are mainly caused by the reference populations of different ethnic backgrounds. For practitioners, the choices of the standards/references depend on the population to be assessed and the purpose of the study. The new China references could be applied to facilitate the standardization assessment of growth and nutrition for Chinese children and adolescents in clinical pediatric and public health.

  1. Poster - 19: Investigation of Electron Reference Dosimetry Based on Optimal Chamber Shift

    Energy Technology Data Exchange (ETDEWEB)

    Zhan, Lixin; Jiang, Runqing; Liu, Baochang; Osei, Ernest [Grand River Regional Cancer Centre (Canada)

    2016-08-15

    An addendum/revision to AAPM TG-51 electron reference dosimetry is highly expected to meet the clinical requirement with the increasing usage of new ion chambers not covered in TG-51. A recent study, Med. Phys. 41, 111701, proposed a new fitting equation for the beam quality conversion factor k’{sub Q} to a wide spectrum of chambers. In the study, an optimal Effective Point of Measurement (EPOM) from Monte Carlo calculations was recommended and the fitting parameters to k’{sub Q} was based on it. We investigated the absolute dose obtained based on the optimal EPOM method and the original TG-51 method with k’{sub R50} determined differently. The results showed that using the Markus curve is a better choice than the well-guarded chamber fitting for an IBA PPC-05 parallel plate chamber if we need to strictly follow the AAPM TG-51 protocol. We also examined the usage of the new fitting equation with measurement performed at the physical EPOM, instead of the optimal EPOM. The former is more readily determined and more practical in clinics. Our study indicated that the k’{sub Q} fitting based on the optimal EPOM can be used to measurement at the physical EPOM with no significant clinical impact. The inclusion of Farmer chamber gradient correction P{sub gr} in k’{sub Q}, as in the mentioned study, asks for the precise positioning of chamber center at dref. It is not recommended in clinics to avoid over-correction for low electron energies, especially for an institute having matching Linacs implemented.

  2. Platinum stable isotope analysis of geological standard reference materials by double-spike MC-ICPMS

    DEFF Research Database (Denmark)

    Creech, John Benjamin; Baker, J. A.; Handler, M. R.

    2014-01-01

    . Double-spiking of samples was carried out prior to digestion and chemical separation to correct for any mass-dependent fractionation that may occur due to incomplete recovery of Pt. Samples were digested using a NiS fire assay method, which pre-concentrates Pt into a metallic bead that is readily...... metal standard solution doped with a range of synthetic matrices and results in Pt yields of ≥90% with purity of ≥95%. Using this chemical separation technique, we have separated Pt from 11 international geological standard reference materials comprising of PGE ores, mantle rocks, igneous rocks and one...

  3. Benefits of a Pharmacology Antimalarial Reference Standard and Proficiency Testing Program Provided by the Worldwide Antimalarial Resistance Network (WWARN)

    Science.gov (United States)

    Lourens, Chris; Lindegardh, Niklas; Barnes, Karen I.; Guerin, Philippe J.; Sibley, Carol H.; White, Nicholas J.

    2014-01-01

    Comprehensive assessment of antimalarial drug resistance should include measurements of antimalarial blood or plasma concentrations in clinical trials and in individual assessments of treatment failure so that true resistance can be differentiated from inadequate drug exposure. Pharmacometric modeling is necessary to assess pharmacokinetic-pharmacodynamic relationships in different populations to optimize dosing. To accomplish both effectively and to allow comparison of data from different laboratories, it is essential that drug concentration measurement is accurate. Proficiency testing (PT) of laboratory procedures is necessary for verification of assay results. Within the Worldwide Antimalarial Resistance Network (WWARN), the goal of the quality assurance/quality control (QA/QC) program is to facilitate and sustain high-quality antimalarial assays. The QA/QC program consists of an international PT program for pharmacology laboratories and a reference material (RM) program for the provision of antimalarial drug standards, metabolites, and internal standards for laboratory use. The RM program currently distributes accurately weighed quantities of antimalarial drug standards, metabolites, and internal standards to 44 pharmacology, in vitro, and drug quality testing laboratories. The pharmacology PT program has sent samples to eight laboratories in four rounds of testing. WWARN technical experts have provided advice for correcting identified problems to improve performance of subsequent analysis and ultimately improved the quality of data. Many participants have demonstrated substantial improvements over subsequent rounds of PT. The WWARN QA/QC program has improved the quality and value of antimalarial drug measurement in laboratories globally. It is a model that has potential to be applied to strengthening laboratories more widely and improving the therapeutics of other infectious diseases. PMID:24777099

  4. Characterization of human lymphoid cell lines GM9947 and GM9948 as intra- and interlaboratory reference standards for DNA typing

    Energy Technology Data Exchange (ETDEWEB)

    Fregeau, C.J.; Elliott, J.C.; Fourney, R.M. [RCMP Central Forensic Laboratory, Ottawa, Ontario (Canada)] [and others

    1995-07-20

    The incorporation of reference DNA is crucial to the validation of any DNA typing protocol. Currently, reference DNA standards are restricted to molecular size DNA ladders and/or tumor cell line DNA. Either of these, however, presents some limitations. We have rigorously characterized two Epstein-Barr virus (EBV)-immortalized human lymphoid cell lines-GM9947 (female) and GM9948 (male)-to determine their suitability as alternative in-line standards for three widely employed allele profiling strategies. Twenty-one highly polymorphic VNTR-based allelic systems (7 RFLPs, 2 AmpFLPs, and 12 STRs) distributed over 12 chromosomes were scrutinized along with 3 gender-based discriminatory systems. The genetic stability of each locus was confirmed over a period of 225 in vitro population doublings. Allele size estimates and degree of informativeness for each of the 21 VNTR systems were compiled. The reproducibility of allele scoring by traditional RFLP analyses, using both cell lines as reference standards, was also verified by an interlaboratory validation study involving 13 analysts from two geographically distinct forensic laboratories. Taken together, our data indicate that GM9947 and GM9948 genomic DNAs could be adopted as reliable reference standards for DNA typing. 82 refs., 3 figs., 8 tabs.

  5. Color standardization and optimization in Whole Slide Imaging

    Directory of Open Access Journals (Sweden)

    Yagi Yukako

    2011-03-01

    Full Text Available Abstract Introduction Standardization and validation of the color displayed by digital slides is an important aspect of digital pathology implementation. While the most common reason for color variation is the variance in the protocols and practices in the histology lab, the color displayed can also be affected by variation in capture parameters (for example, illumination and filters, image processing and display factors in the digital systems themselves. Method We have been developing techniques for color validation and optimization along two paths. The first was based on two standard slides that are scanned and displayed by the imaging system in question. In this approach, one slide is embedded with nine filters with colors selected especially for H&E stained slides (looking like tiny Macbeth color chart; the specific color of the nine filters were determined in our previous study and modified for whole slide imaging (WSI. The other slide is an H&E stained mouse embryo. Both of these slides were scanned and the displayed images were compared to a standard. The second approach was based on our previous multispectral imaging research. Discussion As a first step, the two slide method (above was used to identify inaccurate display of color and its cause, and to understand the importance of accurate color in digital pathology. We have also improved the multispectral-based algorithm for more consistent results in stain standardization. In near future, the results of the two slide and multispectral techniques can be combined and will be widely available. We have been conducting a series of researches and developing projects to improve image quality to establish Image Quality Standardization. This paper discusses one of most important aspects of image quality – color.

  6. Absolute Salinity, ''Density Salinity'' and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    Science.gov (United States)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2011-01-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. However, the Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical

  7. Absolute Salinity, "Density Salinity" and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    Science.gov (United States)

    Wright, D. G.; Pawlowicz, R.; McDougall, T. J.; Feistel, R.; Marion, G. M.

    2010-08-01

    Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models. First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. The Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies. Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol SAdens; it stands out as the most appropriate representation of salinity for use in dynamical physical

  8. Determination of polychlorinated dibenzo-p-dioxin and dibenzofuran congeners in air particulate and marine sediment standard reference materials (SRMs).

    Science.gov (United States)

    Chiu, C H; Turle, R; Poole, G; Thibert, B; Brubaker, W W; Schantz, M M; Wise, S A

    2001-02-01

    Due to the limited number of environmental matrix certified reference materials (CRMs) with assigned values for natural levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), an interlaboratory study was undertaken by the National Institute of Standards and Technology (NIST) and Environment Canada to establish reference concentration values for selected PCDD/Fs in two well-characterized NIST Standard Reference Materials (SRMs): SRM 1649a (Urban Dust) and SRM 1944 (New York/New Jersey Waterway Sediment). Results from 14 laboratories were used to provide reference values for the seventeen 2, 3, 7, 8-substituted PCDD/F congeners, the totals for individual tetra- through hepta-substituted PCDD/F homologues, and the total amount of tetra- through hepta-substituted PCDD/Fs. The mass fractions for the individual 2, 3, 7, 8-substituted congeners range from approximately 0.01 microg/kg to 7 microg/kg dry mass.

  9. Global panel of HIV-1 Env reference strains for standardized assessments of vaccine-elicited neutralizing antibodies.

    Science.gov (United States)

    deCamp, Allan; Hraber, Peter; Bailer, Robert T; Seaman, Michael S; Ochsenbauer, Christina; Kappes, John; Gottardo, Raphael; Edlefsen, Paul; Self, Steve; Tang, Haili; Greene, Kelli; Gao, Hongmei; Daniell, Xiaoju; Sarzotti-Kelsoe, Marcella; Gorny, Miroslaw K; Zolla-Pazner, Susan; LaBranche, Celia C; Mascola, John R; Korber, Bette T; Montefiori, David C

    2014-03-01

    Standardized assessments of HIV-1 vaccine-elicited neutralizing antibody responses are complicated by the genetic and antigenic variability of the viral envelope glycoproteins (Envs). To address these issues, suitable reference strains are needed that are representative of the global epidemic. Several panels have been recommended previously, but no clear answers have been available on how many and which strains are best suited for this purpose. We used a statistical model selection method to identify a global panel of reference Env clones from among 219 Env-pseudotyped viruses assayed in TZM-bl cells with sera from 205 HIV-1-infected individuals. The Envs and sera were sampled globally from diverse geographic locations and represented all major genetic subtypes and circulating recombinant forms of the virus. Assays with a panel size of only nine viruses adequately represented the spectrum of HIV-1 serum neutralizing activity seen with the larger panel of 219 viruses. An optimal panel of nine viruses was selected and augmented with three additional viruses for greater genetic and antigenic coverage. The spectrum of HIV-1 serum neutralizing activity seen with the final 12-virus panel closely approximated the activity seen with subtype-matched viruses. Moreover, the final panel was highly sensitive for detection of many of the known broadly neutralizing antibodies. For broader assay applications, all 12 Env clones were converted to infectious molecular clones using a proviral backbone carrying a Renilla luciferase reporter gene (Env.IMC.LucR viruses). This global panel should facilitate highly standardized assessments of vaccine-elicited neutralizing antibodies across multiple HIV-1 vaccine platforms in different parts of the world. An effective HIV-1 vaccine will need to overcome the extraordinary genetic variability of the virus, where most variation occurs in the viral envelope glycoproteins that are the sole targets for neutralizing antibodies. Efforts to elicit

  10. The stability of uranium microspheres for future application as reference standard in analytical measurements

    Energy Technology Data Exchange (ETDEWEB)

    Middendorp, R.; Duerr, M.; Bosbach, D. [Forschungszentrum Juelich GmbH, IEK-6, 52428 Juelich (Germany)

    2016-07-01

    The monitoring of fuel-cycle facilities provides a tool to confirm the compliant operation, for example with respect to emissions into the environment or to supervise non-proliferation commitments. Hereby, anomalous situations can be detected in a timely manner and responsive action can be initiated to prevent an escalation into an event of severe consequence to society. In order to verify non-nuclear weapon states' compliance with the non-proliferation treaty (NPT), international authorities such as the International Atomic Energy Agency (IAEA) conduct inspections at facilities dealing with fissile or fertile nuclear materials. One measure consists of collection of swipe samples through inspectors for later analysis of collected nuclear material traces in the laboratory. Highly sensitive mass spectrometric methods provide a means to detect traces from nuclear material handling activities that provide indication of undeclared use of the facility. There are, however, no relevant (certified) reference materials available that can be used as calibration or quality control standards. Therefore, an aerosol-generation based process was established at Forschungszentrum Juelich for the production of spherical, mono-disperse uranium oxide micro-particles with accurately characterized isotopic compositions and amounts of uranium in the pico-gram range. The synthesized particles are studied with respect to their suitability as (certified) reference material in ultra-trace analysis. Several options for preparation and stabilization of the particles are available, where preparation of particles in suspension offers the possibility to produces specific particle mixtures. In order to assess the stability of particles, dissolution behavior and isotope exchange effects of particles in liquid suspension is studied on the bulk of suspended particles and also via micro-analytical methods applied for single particle characterization. The insights gained within these studies will

  11. Austenitic chromium nickel steel as standard reference material in measurement of thermal and temperature conductivity

    International Nuclear Information System (INIS)

    Binkele, L.

    1990-01-01

    A niobium-stabilized CrNi steel with the NBS designation SRM 735 is introduced as WLF standard reference material in a report by Hust and Giarratano, for the temperature range 300-1200 K and for thermal conductivities around 20 W/mk. However, its specification does not show it to be a direct member of the DIN family of CrNi steels. This report should be regarded as a continuation and supplement to the above-mentioned efforts in America. On the one hand, a solution of a possibly too-narrow specification is aimed at for the reference material, where it is important how sensitive the thermal conductivity is to changes in the chemical composition and changes of the manufacturing parameters and what accuracy can be reached for the reference values with the best measurement techniques. On the other hand, the data base should be expanded and the accuracy of the reference curve should be improved if possible. (orig./MM) [de

  12. Optimal Interpolation scheme to generate reference crop evapotranspiration

    Science.gov (United States)

    Tomas-Burguera, Miquel; Beguería, Santiago; Vicente-Serrano, Sergio; Maneta, Marco

    2018-05-01

    We used an Optimal Interpolation (OI) scheme to generate a reference crop evapotranspiration (ETo) grid, forcing meteorological variables, and their respective error variance in the Iberian Peninsula for the period 1989-2011. To perform the OI we used observational data from the Spanish Meteorological Agency (AEMET) and outputs from a physically-based climate model. To compute ETo we used five OI schemes to generate grids for the five observed climate variables necessary to compute ETo using the FAO-recommended form of the Penman-Monteith equation (FAO-PM). The granularity of the resulting grids are less sensitive to variations in the density and distribution of the observational network than those generated by other interpolation methods. This is because our implementation of the OI method uses a physically-based climate model as prior background information about the spatial distribution of the climatic variables, which is critical for under-observed regions. This provides temporal consistency in the spatial variability of the climatic fields. We also show that increases in the density and improvements in the distribution of the observational network reduces substantially the uncertainty of the climatic and ETo estimates. Finally, a sensitivity analysis of observational uncertainties and network densification suggests the existence of a trade-off between quantity and quality of observations.

  13. SITE SPECIFIC REFERENCE PERSON PARAMETERS AND DERIVED CONCENTRATION STANDARDS FOR THE SAVANNAH RIVER SITE

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, T.

    2013-03-14

    The purpose of this report is twofold. The first is to develop a set of behavioral parameters for a reference person specific for the Savannah River Site (SRS) such that the parameters can be used to determine dose to members of the public in compliance with Department of Energy (DOE) Order 458.1 “Radiation Protection of the Public and the Environment.” A reference person is a hypothetical, gender and age aggregation of human physical and physiological characteristics arrived at by international consensus for the purpose of standardizing radiation dose calculations. DOE O 458.1 states that compliance with the annual dose limit of 100 mrem (1 mSv) to a member of the public may be demonstrated by calculating the dose to the maximally exposed individual (MEI) or to a representative person. Historically, for dose compliance, SRS has used the MEI concept, which uses adult dose coefficients and adult male usage parameters. Beginning with the 2012 annual site environmental report, SRS will be using the representative person concept for dose compliance. The dose to a representative person will be based on 1) the SRS-specific reference person usage parameters at the 95th percentile of appropriate national or regional data, which are documented in this report, 2) the reference person (gender and age averaged) ingestion and inhalation dose coefficients provided in DOE Derived Concentration Technical Standard (DOE-STD-1196-2011), and 3) the external dose coefficients provided in the DC_PAK3 toolbox. The second purpose of this report is to develop SRS-specific derived concentration standards (DCSs) for all applicable food ingestion pathways, ground shine, and water submersion. The DCS is the concentration of a particular radionuclide in water, in air, or on the ground that results in a member of the public receiving 100 mrem (1 mSv) effective dose following continuous exposure for one year. In DOE-STD-1196-2011, DCSs were developed for the ingestion of water, inhalation of

  14. Body Parameters of Czech Breastfed Children Compared to the Czech References and WHO Growth Standards

    Czech Academy of Sciences Publication Activity Database

    Riedlová, J.; Vignerová, J.; Paulová, M.; Musil, V.; Brabec, Marek; Schneidrová, D.

    2017-01-01

    Roč. 44, č. 7 (2017), s. 593-599 ISSN 0301-4460 Grant - others:GA MZd(CZ) NS9974 Institutional support: RVO:67985807 Keywords : breastfed children * Czech reference * Growth charts * WHO growth standards Subject RIV: BB - Applied Statistics, Operational Research OBOR OECD: Statistics and probability Impact factor: 1.240, year: 2016

  15. Setting the standard: The IAEA safety standards set the global reference

    International Nuclear Information System (INIS)

    Williams, L.

    2003-01-01

    For the IAEA, setting and promoting standards for nuclear radiation, waste, and transport safety have been priorities from the start, rooted in the Agency's 1957 Statute. Today, a corpus of international standards are in place that national regulators and industries in many countries are applying, and more are being encouraged and assisted to follow them. Considerable work is done to keep safety standards updated and authoritative. They cover five main areas: the safety of nuclear facilities; radiation protection and safety of radiation sources; safe management of radioactive waste; safe transport of radioactive material; and thematic safety areas, such as emergency preparedness or legal infrastructures. Overall, the safety standards reflect an international consensus on what constitutes a high level of safety for protecting people and the environment. All IAEA Member States can nominate experts for the Agency standards committees and provide comments on draft standards. Through this ongoing cycle of review and feedback, the standards are refined, updated, and extended where needed

  16. Validity Study of a Jump Mat Compared to the Reference Standard Force Plate.

    Science.gov (United States)

    Rogan, Slavko; Radlinger, Lorenz; Imhasly, Caroline; Kneubuehler, Andrea; Hilfiker, Roger

    2015-12-01

    In the field of vertical jump diagnostics, force plates (FP) are the reference standard. Recently, despite a lack of evidence, jump mats have been used increasingly. Important factors in favor of jumping mats are their low cost and portability. This validity study compared the Haynl-Elektronik jump mat (HE jump mat) with the reference standard force plate. Ten healthy volunteers participated and each participant completed three series of five drop jumps (DJ). The parameters ground contact time (GCT) and vertical jump height (VJH) from the HE jump mat and the FP were used to evaluate the concurrent validity. The following statistical calculations were performed: Pearson's correlation (r), Bland-Altman plots (standard and for adjusted trend), and regression equations. The Bland-Altman plots suggest that the HE jump mat measures shorter contact times and higher jump heights than the FP. The trend-adjusted Bland-Altman plot shows higher mean differences and wider wing-spreads of confidence limits during longer GCT. During the VJH the mean differences and the wing-spreads of the confidence limits throughout the range present as relatively constant. The following regression equations were created, as close as possible to the true value: GCT = 5.920385 + 1.072293 × [value HE jump mat] and VJH = -1.73777 + 1.011156 × [value HE jump mat]. The HE jump mat can be recommended in relation to the validity of constraints. In this study, only a part of the quality criteria were examined. For the final recommendation it is advised to examine the HE jump mat on the other quality criteria (test-retest reliability, sensitivity change).

  17. Phenotypic Graphs and Evolution Unfold the Standard Genetic Code as the Optimal

    Science.gov (United States)

    Zamudio, Gabriel S.; José, Marco V.

    2018-03-01

    In this work, we explicitly consider the evolution of the Standard Genetic Code (SGC) by assuming two evolutionary stages, to wit, the primeval RNY code and two intermediate codes in between. We used network theory and graph theory to measure the connectivity of each phenotypic graph. The connectivity values are compared to the values of the codes under different randomization scenarios. An error-correcting optimal code is one in which the algebraic connectivity is minimized. We show that the SGC is optimal in regard to its robustness and error-tolerance when compared to all random codes under different assumptions.

  18. The establishment of a WHO Reference Reagent for anti-malaria (Plasmodium falciparum) human serum.

    Science.gov (United States)

    Bryan, Donna; Silva, Nilupa; Rigsby, Peter; Dougall, Thomas; Corran, Patrick; Bowyer, Paul W; Ho, Mei Mei

    2017-08-05

    At a World Health Organization (WHO) sponsored meeting it was concluded that there is an urgent need for a reference preparation that contains antibodies against malaria antigens in order to support serology studies and vaccine development. It was proposed that this reference would take the form of a lyophilized serum or plasma pool from a malaria-endemic area. In response, an immunoassay standard, comprising defibrinated human plasma has been prepared and evaluated in a collaborative study. A pool of human plasma from a malaria endemic region was collected from 140 single plasma donations selected for reactivity to Plasmodium falciparum apical membrane antigen-1 (AMA-1) and merozoite surface proteins (MSP-1 19 , MSP-1 42 , MSP-2 and MSP-3). This pool was defibrinated, filled and freeze dried into a single batch of ampoules to yield a stable source of naturally occurring antibodies to P. falciparum. The preparation was evaluated by an enzyme-linked immunosorbent assay (ELISA) in a collaborative study with sixteen participants from twelve different countries. This anti-malaria human serum preparation (NIBSC Code: 10/198) was adopted by the WHO Expert Committee on Biological Standardization (ECBS) in October 2014, as the first WHO reference reagent for anti-malaria (Plasmodium falciparum) human serum with an assigned arbitrary unitage of 100 units (U) per ampoule. Analysis of the reference reagent in a collaborative study has demonstrated the benefit of this preparation for the reduction in inter- and intra-laboratory variability in ELISA. Whilst locally sourced pools are regularly use for harmonization both within and between a few laboratories, the presence of a WHO-endorsed reference reagent should enable optimal harmonization of malaria serological assays either by direct use of the reference reagent or calibration of local standards against this WHO reference. The intended uses of this reference reagent, a multivalent preparation, are (1) to allow cross

  19. Measurement of susceptibility artifacts with histogram-based reference value on magnetic resonance images according to standard ASTM F2119.

    Science.gov (United States)

    Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V

    2015-12-01

    The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.

  20. Multicriteria optimization informed VMAT planning

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Huixiao; Craft, David L.; Gierga, David P., E-mail: dgierga@partners.org

    2014-04-01

    We developed a patient-specific volumetric-modulated arc therapy (VMAT) optimization procedure using dose-volume histogram (DVH) information from multicriteria optimization (MCO) of intensity-modulated radiotherapy (IMRT) plans. The study included 10 patients with prostate cancer undergoing standard fractionation treatment, 10 patients with prostate cancer undergoing hypofractionation treatment, and 5 patients with head/neck cancer. MCO-IMRT plans using 20 and 7 treatment fields were generated for each patient on the RayStation treatment planning system (clinical version 2.5, RaySearch Laboratories, Stockholm, Sweden). The resulting DVH of the 20-field MCO-IMRT plan for each patient was used as the reference DVH, and the extracted point values of the resulting DVH of the MCO-IMRT plan were used as objectives and constraints for VMAT optimization. Weights of objectives or constraints of VMAT optimization or both were further tuned to generate the best match with the reference DVH of the MCO-IMRT plan. The final optimal VMAT plan quality was evaluated by comparison with MCO-IMRT plans based on homogeneity index, conformity number of planning target volume, and organ at risk sparing. The influence of gantry spacing, arc number, and delivery time on VMAT plan quality for different tumor sites was also evaluated. The resulting VMAT plan quality essentially matched the 20-field MCO-IMRT plan but with a shorter delivery time and less monitor units. VMAT plan quality of head/neck cancer cases improved using dual arcs whereas prostate cases did not. VMAT plan quality was improved by fine gantry spacing of 2 for the head/neck cancer cases and the hypofractionation-treated prostate cancer cases but not for the standard fractionation–treated prostate cancer cases. MCO-informed VMAT optimization is a useful and valuable way to generate patient-specific optimal VMAT plans, though modification of the weights of objectives or constraints extracted from resulting DVH of MCO

  1. Optimization of radiation protection in nuclear medicine: from reference dosimetry to personalized dosimetry

    International Nuclear Information System (INIS)

    Hadid, Lama

    2011-01-01

    In nuclear medicine, radiopharmaceuticals are distributed in the body through biokinetic processes. Thus, each organ can become a source of radiation delivering a fraction of emitted energy in tissues. Therefore, dose calculations must be assessed accurately and realistically to ensure the patient radiation protection. Absorbed doses were until now based on mathematical standard models and electron transport approximations. The International Commission on Radiological Protection (ICRP) has recently adopted voxel phantoms as a more realistic representation of the reference adult. The main goal of this thesis was to study the influence of the use of the new reference models and Monte Carlo methods on the major dosimetric quantities. In addition, the contribution of patients? specific geometry to the absorbed dose was compared to a standard geometry, enabling the evaluation of uncertainties arising from the reference values. Particular attention was paid to the bone marrow which is characterized by a high radiosensitivity and a complex microscopic structure. An accurate alpha dosimetry was assessed for bone marrow using microscopic images of several trabecular bone sites. The results showed variations in the absorbed fractions as a function of the particles? energy, the skeletal site and the amount of fat within marrow cavities, three parameters which are not taken into account in the values published by the ICRP. Finally, the heterogeneous activity distribution of the radiopharmaceuticals was considered within the framework of the treatment of a hepato-cellular carcinoma with selective internal radiotherapy using Yttrium-90 through the analysis of dose-volume histograms. The developments made in this thesis show the importance and the feasibility of performing a personalized dosimetry for nuclear medicine patients. (author)

  2. Quantitative micro x-ray fluorescence analyses without reference standard material; Referenzprobenfreie quantitative Mikro-Roentgenfluoreszenzanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, Timo

    2009-07-15

    X-ray fluorescence analysis (XRF) is a standard method for non-destructive investigations. Due to the development of polycapillary optics and SDDdetectors requiring no cooling with liquid nitrogen, XRF becomes a suitable method for a large number of applications, e. g. for the analysis of objects in arts and archaeology. Spectrometers developed for those purposes allow investigations outside of laboratories und provide excitation areas with diameters of 10-70 {mu}m. In most applications, quantification of XRF data is realized by the usage of standard reference materials. Due to absorption processes in the samples the accuracy of the results depends strongly on the similarity of the sample and the reference standard. In cases where no suitable references are available, quantification can be done based on the ''fundamental parameter (fp) method''. This quantification procedure is based on a set of equations describing the fluorescence production and detection mathematical. The cross sections for the interaction of x-rays with matter can be taken from different databases. During an iteration process the element concentrations can be determined. Quantitative XRF based on fundamental parameters requires an accurate knowledge of the excitation spectrum. In case of a conventional setup this spectrum is given by the X-ray tube spectrum and can be calculated. The use of polycapillary optics in micro-XRF spectrometers changes the spectral distribution of the excitation radiation. For this reason it is necessary to access the transmission function of the used optic. The aim of this work is to find a procedure to describe this function for routine quantification based on fundamental parameters. Most of the measurements have been carried out using a commercial spectrometer developed for applications in arts and archaeology. On the one hand the parameters of the lens, used in the spectrometer, have been investigated by different experimental characterization

  3. Validation of IRDFF in 252Cf Standard and IRDF-2002 Reference Neutron Fields

    Directory of Open Access Journals (Sweden)

    Simakov Stanislav

    2016-01-01

    Full Text Available The results of validation of the latest release of International Reactor Dosimetry and Fusion File, IRDFF-1.03, in the standard 252Cf(s.f. and reference 235U(nth,f neutron benchmark fields are presented. The spectrum-averaged cross sections were shown to confirm IRDFF-1.03 in the 252Cf standard spontaneous fission spectrum; that was not the case for the current recommended spectra for 235U(nth,f. IRDFF was also validated in the spectra of the research reactor facilities ISNF, Sigma-Sigma and YAYOI, which are available in the IRDF-2002 collection. The ISNF facility was re-simulated to remove unphysical oscillations in the spectrum. IRDFF-1.03 was shown to reproduce reasonably well the spectrum-averaged data measured in these fields except for the case of YAYOI.

  4. Output Feedback Adaptive Control of Non-Minimum Phase Systems Using Optimal Control Modification

    Science.gov (United States)

    Nguyen, Nhan; Hashemi, Kelley E.; Yucelen, Tansel; Arabi, Ehsan

    2018-01-01

    This paper describes output feedback adaptive control approaches for non-minimum phase SISO systems with relative degree 1 and non-strictly positive real (SPR) MIMO systems with uniform relative degree 1 using the optimal control modification method. It is well-known that the standard model-reference adaptive control (MRAC) cannot be used to control non-SPR plants to track an ideal SPR reference model. Due to the ideal property of asymptotic tracking, MRAC attempts an unstable pole-zero cancellation which results in unbounded signals for non-minimum phase SISO systems. The optimal control modification can be used to prevent the unstable pole-zero cancellation which results in a stable adaptation of non-minimum phase SISO systems. However, the tracking performance using this approach could suffer if the unstable zero is located far away from the imaginary axis. The tracking performance can be recovered by using an observer-based output feedback adaptive control approach which uses a Luenberger observer design to estimate the state information of the plant. Instead of explicitly specifying an ideal SPR reference model, the reference model is established from the linear quadratic optimal control to account for the non-minimum phase behavior of the plant. With this non-minimum phase reference model, the observer-based output feedback adaptive control can maintain stability as well as tracking performance. However, in the presence of the mismatch between the SPR reference model and the non-minimum phase plant, the standard MRAC results in unbounded signals, whereas a stable adaptation can be achieved with the optimal control modification. An application of output feedback adaptive control for a flexible wing aircraft illustrates the approaches.

  5. A preliminary comparative study on the content of cesium, thorium and uranium in IAEA standard reference material

    International Nuclear Information System (INIS)

    Zhang Jing; Liu Husheng; Wang Xiaoyan; Wang Naifen

    2000-01-01

    This paper presents the detection of Cs, Th and U in 6 standard reference materials provided by IAEA, using the ICP-MS method. The bismuth (Bi) was selected as internal standard element for the range compensation of matrix inhibitory effect and flow of the sensibility. The detection limit of the 3 elements was limited in the range of 0.0006∼2ng/ml, 0.4∼0.5g sample was taken and digested by acid, and detected directly by ICP-MS. The recovery of standard addition was 82.1∼100.1%

  6. Outcomes of Optimized over Standard Protocol of Rabbit Antithymocyte Globulin for Severe Aplastic Anemia: A Single-Center Experience

    Science.gov (United States)

    Ge, Meili; Shao, Yingqi; Huang, Jinbo; Huang, Zhendong; Zhang, Jing; Nie, Neng; Zheng, Yizhou

    2013-01-01

    Background Previous reports showed that outcome of rabbit antithymocyte globulin (rATG) was not satisfactory as the first-line therapy for severe aplastic anemia (SAA). We explored a modifying schedule of administration of rATG. Design and Methods Outcomes of a cohort of 175 SAA patients, including 51 patients administered with standard protocol (3.55 mg/kg/d for 5 days) and 124 cases with optimized protocol (1.97 mg/kg/d for 9 days) of rATG plus cyclosporine (CSA), were analyzed retrospectively. Results Of all 175 patients, response rates at 3 and 6 months were 36.6% and 56.0%, respectively. 51 cases received standard protocol had poor responses at 3 (25.5%) and 6 months (41.2%). However, 124 patients received optimized protocol had better responses at 3 (41.1%, P = 0.14) and 6 (62.1%, P = 0.01). Higher incidences of infection (57.1% versus 37.9%, P = 0.02) and early mortality (17.9% versus 0.8%, P<0.001) occurred in patients received standard protocol compared with optimized protocol. The 5-year overall survival in favor of the optimized over standard rATG protocol (76.0% versus. 50.3%, P<0.001) was observed. By multivariate analysis, optimized protocol (RR = 2.21, P = 0.04), response at 3 months (RR = 10.31, P = 0.03) and shorter interval (<23 days) between diagnosis and initial dose of rATG (RR = 5.35, P = 0.002) were independent favorable predictors of overall survival. Conclusions Optimized instead of standard rATG protocol in combination with CSA remained efficacious as a first-line immunosuppressive regimen for SAA. PMID:23554855

  7. Standardized Semantic Markup for Reference Terminologies, Thesauri and Coding Systems: Benefits for distributed E-Health Applications.

    Science.gov (United States)

    Hoelzer, Simon; Schweiger, Ralf K; Liu, Raymond; Rudolf, Dirk; Rieger, Joerg; Dudeck, Joachim

    2005-01-01

    With the introduction of the ICD-10 as the standard for diagnosis, the development of an electronic representation of its complete content, inherent semantics and coding rules is necessary. Our concept refers to current efforts of the CEN/TC 251 to establish a European standard for hierarchical classification systems in healthcare. We have developed an electronic representation of the ICD-10 with the extensible Markup Language (XML) that facilitates the integration in current information systems or coding software taking into account different languages and versions. In this context, XML offers a complete framework of related technologies and standard tools for processing that helps to develop interoperable applications.

  8. Baseline Assessment of 25-Hydroxyvitamin D Reference Material and Proficiency Testing/External Quality Assurance Material Commutability: A Vitamin D Standardization Program Study.

    Science.gov (United States)

    Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M

    2017-09-01

    The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.

  9. Developing regional weight-for-age growth references for malaria-endemic countries to optimize age-based dosing of antimalarials

    NARCIS (Netherlands)

    Hayes, Daniel J.; van Buuren, Stef; ter Kuile, Feiko O.; Stasinopoulos, D. Mikis; Rigby, Robert A.; Terlouw, Dianne J.

    2015-01-01

    To derive regional weight-for-age growth references to help optimize age-based dosing of antimalarials in Africa, the Americas, South-East Asia and the Western Pacific. A weight-for-age database was constructed from pre-existing population-based anthropometric data obtained from household surveys

  10. Kernel reconstruction methods for Doppler broadening — Temperature interpolation by linear combination of reference cross sections at optimally chosen temperatures

    International Nuclear Information System (INIS)

    Ducru, Pablo; Josey, Colin; Dibert, Karia; Sobes, Vladimir; Forget, Benoit; Smith, Kord

    2017-01-01

    This paper establishes a new family of methods to perform temperature interpolation of nuclear interactions cross sections, reaction rates, or cross sections times the energy. One of these quantities at temperature T is approximated as a linear combination of quantities at reference temperatures (T_j). The problem is formalized in a cross section independent fashion by considering the kernels of the different operators that convert cross section related quantities from a temperature T_0 to a higher temperature T — namely the Doppler broadening operation. Doppler broadening interpolation of nuclear cross sections is thus here performed by reconstructing the kernel of the operation at a given temperature T by means of linear combination of kernels at reference temperatures (T_j). The choice of the L_2 metric yields optimal linear interpolation coefficients in the form of the solutions of a linear algebraic system inversion. The optimization of the choice of reference temperatures (T_j) is then undertaken so as to best reconstruct, in the L∞ sense, the kernels over a given temperature range [T_m_i_n,T_m_a_x]. The performance of these kernel reconstruction methods is then assessed in light of previous temperature interpolation methods by testing them upon isotope "2"3"8U. Temperature-optimized free Doppler kernel reconstruction significantly outperforms all previous interpolation-based methods, achieving 0.1% relative error on temperature interpolation of "2"3"8U total cross section over the temperature range [300 K,3000 K] with only 9 reference temperatures.

  11. Absolute Salinity, ''Density Salinity'' and the Reference-Composition Salinity Scale: present and future use in the seawater standard TEOS-10

    Directory of Open Access Journals (Sweden)

    D. G. Wright

    2011-01-01

    Full Text Available Salinity plays a key role in the determination of the thermodynamic properties of seawater and the new TEOS-101 standard provides a consistent and effective approach to dealing with relationships between salinity and these thermodynamic properties. However, there are a number of practical issues that arise in the application of TEOS-10, both in terms of accuracy and scope, including its use in the reduction of field data and in numerical models.

    First, in the TEOS-10 formulation for IAPSO Standard Seawater, the Gibbs function takes the Reference Salinity as its salinity argument, denoted SR, which provides a measure of the mass fraction of dissolved material in solution based on the Reference Composition approximation for Standard Seawater. We discuss uncertainties in both the Reference Composition and the Reference-Composition Salinity Scale on which Reference Salinity is reported. The Reference Composition provides a much-needed fixed benchmark but modified reference states will inevitably be required to improve the representation of Standard Seawater for some studies. However, the Reference-Composition Salinity Scale should remain unaltered to provide a stable representation of salinity for use with the TEOS-10 Gibbs function and in climate change detection studies.

    Second, when composition anomalies are present in seawater, no single salinity variable can fully represent the influence of dissolved material on the thermodynamic properties of seawater. We consider three distinct representations of salinity that have been used in previous studies and discuss the connections and distinctions between them. One of these variables provides the most accurate representation of density possible as well as improvements over Reference Salinity for the determination of other thermodynamic properties. It is referred to as "Density Salinity" and is represented by the symbol

  12. Simultaneous Determination of Four Anthraquinones in Polygoni Multiflori Radix with Single Reference Standard by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Hua Yang

    2015-07-01

    Full Text Available Objective: To establish a rapid, accurate and reliable analytical method for the simultaneous determination of four major anthraquinones in Polygoni Multiflori Radix (PMR using single reference standard.

  13. Standardized procedure for eddy-current testing of stainless steel, thin-walled nuclear fuel element cladding tubes

    Energy Technology Data Exchange (ETDEWEB)

    Barat, P; Raj, B; Bhattacharya, D K [Reactor Research Centre, Kalpakkam (India)

    1982-10-01

    Thin-walled nuclear fuel cladding tubes made of AISI 316 stainless steel have been examined by eddy-current testing. Standardization of the procedures has required investigations on optimizing the test frequency, finding a method to locate a defect with respect to the probe reference end, and the use of standard defects and sequential metallography of natural defects detected by eddy-current testing, to understand the influence of the nature of defects on the impedance output signals. Test frequency and method of locating the defect were optimized by the use of standard defects made by machining in reference cladding tubes. Subsequent metallography of natural defects detected by eddy-current testing revealed mainly clusters of inclusions but also other types of defects. The effect of the distribution of inclusions along the length of the tube on the impedance output is discussed.

  14. Thermal Expansion and Density Data of UO2 and Simulated Fuel for Standard Reference

    International Nuclear Information System (INIS)

    Yang, Jae Hwan; Na, S. H.; Lee, J. W.; Kang, K. H.

    2010-01-01

    Standard Reference Data (SRD) is the scientific, technical data whose reliability and accuracy are evaluated by scientist group. Since SRD has a great impact on the improvement of national competitiveness by stirring up technological innovation in every sector of industries, many countries are making great efforts on establishing SRD in various areas. Data center for nuclear fuel material in Korea Atomic Energy Research Institute plays a role to providing property data of nuclear fuel material at high temperature, pressure, and radiation which are essential for the safety evaluation of nuclear power. In this study, standardization of data on thermal expansion and density of UO 2 were carried out in the temperature range from 300 K to 3100 K via uncertainty evaluation of indirectly produced data. Besides, standardization of data on thermal expansion and density of simulated fuel were also done in the temperature range from 350 K to 1750 K via uncertainty evaluation of directly produced data

  15. The NIST natural-matrix radionuclide standard reference material program for ocean studies

    International Nuclear Information System (INIS)

    Inn, K.G.W.; Zhichao Lin; Zhongyu Wu; MacMahon, C.; Filliben, J.J.; Krey, P.; Feiner, M.; Harvey, J.

    2001-01-01

    In 1997, the Low-level Working Group of the International Committee on Radionuclide Metrology met in Boston, MA (USA) to define the characteristics of a new set of environmental radioactivity reference materials. These reference materials were to provide the radiochemist with the same analytical challenges faced when assaying environmental samples. It was decided that radionuclide bearing natural materials should be collected from sites where there had been sufficient time for natural processes to redistribute the various chemically different species of the radionuclides. Over the succeeding years, the National Institute of Standards and Technology (NIST), in cooperation with other highly experienced laboratories, certified and issued a number of these as low-level radioactivity Standard Reference Materials (SRMs) for fission and activation product and actinide concentrations. The experience of certifying these SRMs has given NIST the opportunity to compare radioanalytical methods and learn of their limitations. NIST convened an international workshop in 1994 to define the natural-matrix radionuclide SRM needs for ocean studies. The highest priorities proposed at the workshop were for sediment, shellfish, seaweed, fish flesh and water matrix SRMs certified for mBq per sample concentrations of 90 Sr, 137 Cs and 239 Pu + 240 Pu. The most recent low-level environmental radionuclide SRM issued by NIST, Ocean Sediment (SRM 4357) has certified and uncertified values for the following 22 radionuclides: 40 K, 90 Sr, 129 I, 137 Cs, 155 Eu, 210 Pb, 210 Po, 212 Pb, 214 Bi, 226 Ra, 228 Ra, 228 Th, 230 Th, 232 Th, 234 U, 235 U, 237 Np, 238 U, 238 Pu, 239 Pu + 240 Pu, and 241 Am. The uncertainties for a number of the certified radionuclides are non-symmetrical and relatively large because of the non-normal distribution of reported values. NIST is continuing its efforts to provide the ocean studies community with additional natural matrix radionuclide SRMs. The freeze

  16. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    Science.gov (United States)

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  17. Reference Materials for Calibration of Analytical Biases in Quantification of DNA Methylation.

    Science.gov (United States)

    Yu, Hannah; Hahn, Yoonsoo; Yang, Inchul

    2015-01-01

    Most contemporary methods for the quantification of DNA methylation employ bisulfite conversion and PCR amplification. However, many reports have indicated that bisulfite-mediated PCR methodologies can result in inaccurate measurements of DNA methylation owing to amplification biases. To calibrate analytical biases in quantification of gene methylation, especially those that arise during PCR, we utilized reference materials that represent exact bisulfite-converted sequences with 0% and 100% methylation status of specific genes. After determining relative quantities using qPCR, pairs of plasmids were gravimetrically mixed to generate working standards with predefined DNA methylation levels at 10% intervals in terms of mole fractions. The working standards were used as controls to optimize the experimental conditions and also as calibration standards in melting-based and sequencing-based analyses of DNA methylation. Use of the reference materials enabled precise characterization and proper calibration of various biases during PCR and subsequent methylation measurement processes, resulting in accurate measurements.

  18. A standardized procedure for eddy-current testing of stainless steel, thin-walled nuclear fuel element cladding tubes

    International Nuclear Information System (INIS)

    Barat, P.; Raj, B.; Bhattacharya, D.K.

    1982-01-01

    Thin-walled nuclear fuel cladding tubes made of AISI 316 stainless steel have been examined by eddy-current testing. Standardization of the procedures has required investigations on optimizing the test frequency, finding a method to locate a defect with respect to the probe reference end, and the use of standard defects and sequential metallography of natural defects detected by eddy-current testing, to understand the influence of the nature of defects on the impedance output signals. Test frequency and method of locating the defect were optimized by the use of standard defects made by machining in reference cladding tubes. Subsequent metallography of natural defects detected by eddy-current testing revealed mainly clusters of inclusions but also other types of defects. The effect of the distribution of inclusions along the length of the tube on the impedance output is discussed. (author)

  19. Joint-layer encoder optimization for HEVC scalable extensions

    Science.gov (United States)

    Tsai, Chia-Ming; He, Yuwen; Dong, Jie; Ye, Yan; Xiu, Xiaoyu; He, Yong

    2014-09-01

    Scalable video coding provides an efficient solution to support video playback on heterogeneous devices with various channel conditions in heterogeneous networks. SHVC is the latest scalable video coding standard based on the HEVC standard. To improve enhancement layer coding efficiency, inter-layer prediction including texture and motion information generated from the base layer is used for enhancement layer coding. However, the overall performance of the SHVC reference encoder is not fully optimized because rate-distortion optimization (RDO) processes in the base and enhancement layers are independently considered. It is difficult to directly extend the existing joint-layer optimization methods to SHVC due to the complicated coding tree block splitting decisions and in-loop filtering process (e.g., deblocking and sample adaptive offset (SAO) filtering) in HEVC. To solve those problems, a joint-layer optimization method is proposed by adjusting the quantization parameter (QP) to optimally allocate the bit resource between layers. Furthermore, to make more proper resource allocation, the proposed method also considers the viewing probability of base and enhancement layers according to packet loss rate. Based on the viewing probability, a novel joint-layer RD cost function is proposed for joint-layer RDO encoding. The QP values of those coding tree units (CTUs) belonging to lower layers referenced by higher layers are decreased accordingly, and the QP values of those remaining CTUs are increased to keep total bits unchanged. Finally the QP values with minimal joint-layer RD cost are selected to match the viewing probability. The proposed method was applied to the third temporal level (TL-3) pictures in the Random Access configuration. Simulation results demonstrate that the proposed joint-layer optimization method can improve coding performance by 1.3% for these TL-3 pictures compared to the SHVC reference encoder without joint-layer optimization.

  20. Preparation and certification of trace mercury in water standard reference materials

    International Nuclear Information System (INIS)

    Moody, J.R.; Paulsen, P.J.; Rains, T.C.; Rook, H.L.

    1976-01-01

    The study of mercury in natural water supplies requires a Standard Reference Material (SRM) with a certified concentration at the 1 ng/g level. NBS SRM's have been prepared with nominal mercury concentrations of 1.5 μg/g and 1.2 ng/g. Confirmation of these values was obtained by neutron activation, atomic absorption, and isotope dilution-spark source mass spectrometry (IDSSMS). Nitric acid and trace amounts of gold were added to achieve a stable mercury concentration. The precautions observed for cleaning the glass and Teflon containers, preparation of mercury solutions, and the packaging of the SRM's are given. As an example of the care needed in the analysis of mercury at these levels, specific details are presented for the chemistry required to prepare samples for the spark source mass spectrometer

  1. Topology optimization of fluid mechanics problems

    DEFF Research Database (Denmark)

    Gersborg-Hansen, Allan

    While topology optimization for solid continuum structures have been studied for about 20 years and for the special case of trusses for many more years, topology optimization of fluid mechanics problems is more recent. Borrvall and Petersson [1] is the seminal reference for topology optimization......D Navier-Stokes equation as well as an example with convection dominated transport in 2D Stokes flow. Using Stokes flow limits the range of applications; nonetheless, the present work gives a proof-of-concept for the application of the method within fluid mechanics problems and it remains...... processing tool. Prior to design manufacturing this allows the engineer to quantify the performance of the computed topology design using standard, credible analysis tools with a body-fitted mesh. [1] Borrvall and Petersson (2003) "Topology optimization of fluids in Stokes flow", Int. J. Num. Meth. Fluids...

  2. Implementation of Dietary Reference Intake Standards in Preschool Menus in Poland.

    Science.gov (United States)

    Myszkowska-Ryciak, Joanna; Harton, Anna

    2018-05-10

    Although the nutritional value of preschool menus largely determines the proper nutrition of attending children, their nutrient composition often does not meet the standards. The purpose of the study was to assess the nutritional value of menus served in preschools throughout Poland. We analyzed a sample of 10 daily menus and inventory reports reflecting foods and beverages served in 270 full-board government-sponsored preschools. Nutrient content was calculated per child per day, and compared with 70% of dietary reference intake (DRI) for children aged 1⁻3 and 4⁻6. The content of energy, protein, fat, and carbohydrates generally exceeded 70% of DRI. The amount of vitamins was correct, with the exception of vitamin D (100% of daycare centers (DCCs) were below the recommendations); in ≤3% of preschools vitamin E, folate, and niacin were below DRI. Calcium was too low in 63% of preschools for children aged 1⁻3 years and in 99% for 4⁻6-year-olds. A shortage of iodine, iron, and potassium (especially for 4⁻6-year-olds) was observed in a small number of preschools. Our study highlights the need for uniform legal standards of nutrition in childcare centers, based on the current recommendations for the age group.

  3. Event-specific qualitative and quantitative detection of five genetically modified rice events using a single standard reference molecule.

    Science.gov (United States)

    Kim, Jae-Hwan; Park, Saet-Byul; Roh, Hyo-Jeong; Shin, Min-Ki; Moon, Gui-Im; Hong, Jin-Hwan; Kim, Hae-Yeong

    2017-07-01

    One novel standard reference plasmid, namely pUC-RICE5, was constructed as a positive control and calibrator for event-specific qualitative and quantitative detection of genetically modified (GM) rice (Bt63, Kemingdao1, Kefeng6, Kefeng8, and LLRice62). pUC-RICE5 contained fragments of a rice-specific endogenous reference gene (sucrose phosphate synthase) as well as the five GM rice events. An existing qualitative PCR assay approach was modified using pUC-RICE5 to create a quantitative method with limits of detection correlating to approximately 1-10 copies of rice haploid genomes. In this quantitative PCR assay, the square regression coefficients ranged from 0.993 to 1.000. The standard deviation and relative standard deviation values for repeatability ranged from 0.02 to 0.22 and 0.10% to 0.67%, respectively. The Ministry of Food and Drug Safety (Korea) validated the method and the results suggest it could be used routinely to identify five GM rice events. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Age and gender leucocytes variances and references values generated using the standardized ONE-Study protocol

    DEFF Research Database (Denmark)

    Kverneland, Anders H.; Streitz, Mathias; Geissler, Edward

    2016-01-01

    blood flow cytometry. The performance of our protocols was challenged here by profiling samples from healthy volunteers to reveal age- and gender-dependent differences and to establish a standardized reference cohort for use in clinical trials. Whole blood samples from two different cohorts were...... analyzed (first cohort: n = 52, second cohort: n = 46, both 20–84 years with equal gender distribution). The second cohort was run as a validation cohort by a different operator. The “ONE Study” panels were applied to analyze expression of >30 different surface markers to enumerate proportional...... cohort. Thus, we have proven the utility of our strategy and generated reproducible reference ranges accounting for age- and gender-dependent differences, which are crucial for a better patient monitoring and individualized therapy....

  5. Valores de referência para carboxiemoglobina Reference values for carboxyhemoglobin

    Directory of Open Access Journals (Sweden)

    Maria Elisa P. B. de Siqueira

    1997-12-01

    the present study, the RV for carboxyhemoglobin (COHb was determined for the South of Minas Gerais. MATERIAL AND METHOD: The COHb was analyzed by the Beutler and West (1984 spectrophotometric method, optimized in our laboratory. In all the samples, analyses of some biochemical and hematological parameters were made to evaluate the health condition of a population of 200 volunteer non-smokers occupationally not exposed to CO. Each individual answered a questionnaire to obtain data pertinent to the interpretation of the results. The reference values were expressed as mean values ± standard deviation, with a 95% confidence interval, and an upper reference value. The statistical distribution of the results was made so as to enable comparisons between the results of groups of workers, rather than individual evaluations, to be made. RESULTS AND CONCLUSION: The mean value ± standard deviation was 1.0% ± 0.75; the 95% confidence interval was 0,9 - 1.1% and the upper reference value was 2.5%. By the t Student test (p < 0.05, no difference was detected between the values related to sex, age or ingestion of alcoholic beverages. The reference values obtained were close to those reported for others countries.

  6. Standards for reference reactor physics measurements

    International Nuclear Information System (INIS)

    Harris, D.R.; Cokinos, D.M.; Uotinen, V.

    1990-01-01

    Reactor physics analysis methods require experimental testing and confirmation over the range of practical reactor configurations and states. This range is somewhat limited by practical fuel types such as actinide oxides or carbides enclosed in metal cladding. On the other hand, this range continues to broaden because of the trend of using higher enrichment, if only slightly enriched, electric utility fuel. The need for experimental testing of the reactor physics analysis methods arises in part because of the continual broadening of the range of core designs, and in part because of the nature of the analysis methods. Reactor physics analyses are directed primarily at the determination of core reactivities and reaction rates, the former largely for reasons of reactor control, and the latter largely to ensure that material limitations are not violated. Errors in these analyses can be regarded as being from numerics, from the data base, and from human factors. For numerical, data base, and human factor reasons, then, it is prudent and customary to qualify reactor physical analysis methods against experiments. These experiments can be treated as being at low power or at high power, and each of these types is subject to an American National Standards Institute standard. The purpose of these standards is to aid in improving and maintaining adequate quality in reactor physics methods, and it is from this point of view that the standards are examined here

  7. Body mass index in Saudi Arabian children and adolescents: A national reference and comparison with international standards

    International Nuclear Information System (INIS)

    Al Herbish, Abdullah S; ElMouzan, Mohammed I; AlSalloum, Abdullah A; AlQureshi, Mansour M; AlOmar, Ahmed A; Fster, Peter J; Kecojevic, Tatjana

    2009-01-01

    Because there are no reference standards for body mass index (BMI) in Saudi children, we established BMI reference percentiles for normal Saudi Arabian children and adolescents and compared them with international standards. Data from a stratified multistage probability sample were collected from the 13 health regions in Saudi Arabia, as part of a nationwide health profile survey of Saudi Arabian children and adolescents conducted to establish normal physical growth references. Selected households were visited by a trained team. Weight and length/height were measured and recorded following the WHO recommended procedures using the same equipment, which were subjected to both calibration and intra/interobserver variations. Survey of 11 874 eligible households yielded 35 275 full-term and healthy children and adolescents who were subjected to anthropometric measurements. Four BMI curves were produced, from birth to 36 months and 2 to 19 years for girls and boys. The 3rd, 5th, 10th ,25th , 5oth , 75th ,85th , 90th , 95th , and 97th percentiles were produced and compared with the WHO and CDC BMI charts. In the higher percentiles, the Saudi children differed from Western counterparts, indicating that Saudi children have equal or higher BMIs. The BMI curves reflect statistically representative BMI values for Saudi Arabian children and adolescents. (author)

  8. Quantification of pneumothorax volume on chest radiographs: comparison between the collins' and the axel's methods with three-dimensional CT as the standard of reference

    International Nuclear Information System (INIS)

    Lee, Chang Keun; Kim, Hyung Jin; Lee, Kyung Hee; Kim, Joung Taek; Kim, Kwang Ho; Suh, Chang Hae; Han, Heon

    1999-01-01

    The purpose of this study was twofold. In a preliminary study, we evaluated the accuracy of 3-D (three-dimensional) CT for the estimation of pneumothorax volume and for providing the optimal postprocessing method for clinical study. In the clinical study, we determined which of the two methods, Collins' and Axel's, was more accurate for the estimation of pneumothorax volume, as seen on chest radiographs, using 3-D CT as the standard of reference. In the preliminary study, 3-D CT was applied to phantoms and to four patients with pneumothorax using two different postprocessing methods, manual contour delineation and thresholding. In the clinical study, 3-D CT was performed in 13 patients with pneumothorax. For the purpose of evaluating conventional radiographs, a localizer scan was used for comparing the accuracy of Collins' method with that of Axel's method, with 3-D CT as the standard of reference. The preliminary study revealed that 3-D CT estimated pneumothorax volume with great accuracy and that manual contour delineation and thresholding measured volume equally well. Because of the shorter postprocessing time required with thresholding than with manual contour delineation (5 min versus 30 min), the former was used during clinical study. The results of this indicated close correlation between the measurements obtained using Collins' method on chest radiographs and those obtained by 3-D CT(r=0.95, p 0.05). 3-D CT can estimate pneumothorax volume with great accuracy. Collins' method is superior to Axel's method for the quantification of pneumothorax volume as seen on chest radiographs

  9. Simultaneous determination of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in standard reference material baking chocolate 2384, cocoa, cocoa beans, and cocoa butter.

    Science.gov (United States)

    Risner, Charles H

    2008-01-01

    A reverse-phase liquid chromatography analysis is used to access the quantity of theobromine, (+)-catechin, caffeine, and (-)-epicatechin in Standard Reference Material 2384 Baking Chocolate, cocoa, cocoa beans, and cocoa butter using water or a portion of the mobile phase as the extract. The procedure requires minimal sample preparation. Theobromine, (+)-catechin, caffeine, and (-)-epicatechin are detected by UV absorption at 273 nm after separation using a 0.3% acetic acid-methanol gradient (volume fractions) and quantified using external standards. The limit of detection for theobromine, (+)-catechin, caffeine, and (-)-epicatechin averages 0.08, 0.06, 0.06, and 0.06 microg/mL, respectively. The method when applied to Standard Reference Material 2384 Baking Chocolate; baking chocolate reference material yields results that compare to two different, separate procedures. Theobromine ranges from 26000 mg/kg in cocoa to 140 mg/kg in cocoa butter; (+)-catechin from 1800 mg/kg in cocoa to below detection limits of theobromine, 100.0 +/- 0.6 for (+)-catechin, 96.2 +/- 2.1 for caffeine, and 106.2 +/- 1.7 for (-)-epicatechin.

  10. Adaptive Flight Control Design with Optimal Control Modification on an F-18 Aircraft Model

    Science.gov (United States)

    Burken, John J.; Nguyen, Nhan T.; Griffin, Brian J.

    2010-01-01

    In the presence of large uncertainties, a control system needs to be able to adapt rapidly to regain performance. Fast adaptation is referred to as the implementation of adaptive control with a large adaptive gain to reduce the tracking error rapidly; however, a large adaptive gain can lead to high-frequency oscillations which can adversely affect the robustness of an adaptive control law. A new adaptive control modification is presented that can achieve robust adaptation with a large adaptive gain without incurring high-frequency oscillations as with the standard model-reference adaptive control. The modification is based on the minimization of the Y2 norm of the tracking error, which is formulated as an optimal control problem. The optimality condition is used to derive the modification using the gradient method. The optimal control modification results in a stable adaptation and allows a large adaptive gain to be used for better tracking while providing sufficient robustness. A damping term (v) is added in the modification to increase damping as needed. Simulations were conducted on a damaged F-18 aircraft (McDonnell Douglas, now The Boeing Company, Chicago, Illinois) with both the standard baseline dynamic inversion controller and the adaptive optimal control modification technique. The results demonstrate the effectiveness of the proposed modification in tracking a reference model.

  11. Determinations of elements in pepperbush standard reference material by neutron activation and X-ray fluorescence analyses

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Okada, Takayuki; Tatsumi, Toshiya; Kusakabe, Toshio; Katsurayama, Kousuke; Iwata, Shiro.

    1988-01-01

    Elemental contents in Pepperbush standard reference material have been determined by neutron activation and X-ray fluorescence analyses. The standard samples of orchard leaves, tomato leaves, pine needles and Kale are used for the experiment. In the neutron activation analysis, gamma-ray spectra of nuclei produced by (n,γ) reaction on Pepperbush and standard samples are measured with Ge detectors. In the X-ray fluorescence analysis, the samples are excited with X-rays from X-ray tube with rhodium anode, and the characteristic X-rays from samples are measured with a proportional counter or NaI(Tl) detector. From the gamma- and X-ray intensities, the elemental contents in Pepperbush are determined. As a result, the contents of seventeen elements, such as sodium, calcium, iron, etc., in Pepperbush are determined. (author)

  12. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the PTB and the BIPM

    International Nuclear Information System (INIS)

    Kessler, C.; Allisy-Roberts, P.J.; Selbach, H.J.

    2015-01-01

    An indirect comparison of the standards for reference air kerma rate (RAKR) for 192 Ir high dose rate (HDR) brachytherapy sources of the Physikalisch-Technische Bundesanstalt (PTB), Germany, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the PTB in September 2011. The comparison result, based on the calibration coefficients for a transfer standard and expressed as a ratio of the PTB and the BIPM standards for reference air kerma rate, is 1.0003 with a combined standard uncertainty of 0.0099. (authors)

  13. Deep learning quick reference useful hacks for training and optimizing deep neural networks with TensorFlow and Keras

    CERN Document Server

    Bernico, Michael

    2018-01-01

    This book is a practical guide to applying deep neural networks including MLPs, CNNs, LSTMs, and more in Keras and TensorFlow. Packed with useful hacks to solve real-world challenges along with the supported math and theory around each topic, this book will be a quick reference for training and optimize your deep neural networks.

  14. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    Science.gov (United States)

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  15. Optimization of two methods based on ultrasound energy as alternative to European standards for soluble salts extraction from building materials.

    Science.gov (United States)

    Prieto-Taboada, N; Gómez-Laserna, O; Martinez-Arkarazo, I; Olazabal, M A; Madariaga, J M

    2012-11-01

    The Italian recommendation NORMAL 13/83, later replaced by the UNI 11087/2003 norm, were used as standard for soluble salts extraction from construction materials. These standards are based on long-time stirring (72 and 2h, respectively) of the sample in deionized water. In this work two ultrasound based methods were optimized in order to reduce the extraction time while efficiency is improved. The instrumental variables involved in the extraction assisted by ultrasound bath and focused ultrasounds were optimized by experimental design. As long as it was possible, the same non-instrumental parameters values as those of standard methods were used in order to compare the results obtained on a mortar sample showing a black crust by the standards and the optimized methods. The optimal extraction time for the ultrasounds bath was found to be of two hours. Although the extraction time was equal to the standard UNI 11087/2003, the obtained extraction recovery was improved up to 119%. The focused ultrasound system achieved also better recoveries (up to 106%) depending on the analyte in 1h treatment time. The repeatabilities of the proposed ultrasound based methods were comparables to those of the standards. Therefore, the selection of one or the other of the ultrasound based methods will depend on topics such as laboratory facilities or number of samples, and not in aspects related with their quality parameters. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. A NEW APPROACH FOR CULTURING LEMNA MINOR (DUCKWEED) AND STANDARDIZED METHOD FOR USING ATRAZINE AS A REFERENCE TOXICANT

    Science.gov (United States)

    Lemna minor (Duckweed) is commonly used in aquatic toxicity investigations. Methods for culturing and testing with reference toxicants, such as atrazine, are somewhat variable among researchers. Our goal was to develop standardized methods of culturing and testing for use with L....

  17. Operational radiation protection: A guide to optimization

    International Nuclear Information System (INIS)

    1990-01-01

    The purpose of this publication is to provide practical guidance on the application of the dose limitation system contained in the Basic Safety Standards for Radiation Protection to operational situations both in large nuclear installations and in much smaller facilities. It is anticipated that this Guide will be useful to both the management and radiation protection staff of operations in which there is a potential for occupational radiation exposures and to the competent authorities with responsibilities for providing a programme of regulatory control. Contents: Dose limitation system; Optimization and its practical application to operational radiation protection; Major elements of an effective operational radiation protection programme; Review of selected parts of the basic safety standards with special reference to operational radiation protection; Optimization of radiation protection; Techniques for the systematic appraisal of operational radiation protection programmes. Refs and figs

  18. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  19. Comparison of US Birth Weight References and the International Fetal and Newborn Growth Consortium for the 21st Century Standard

    DEFF Research Database (Denmark)

    Kozuki, Naoko; Katz, Joanne; Christian, Parul

    2015-01-01

    ) status. OBJECTIVES: To compare the birth weight distributions of the INTERGROWTH-21st international standard to commonly used US references and examine the differences in the prevalence and neonatal mortality risk of SGA status (below the 10th percentile of a population reference). DESIGN, SETTING...... variance. MAIN OUTCOMES AND MEASURES: We examine neonatal mortality (death within the first 28 days after birth) as the main outcome measure. RESULTS: The pooled SGA prevalence was 23.7% (95% CI, 16.5%-31.0%) using the INTERGROWTH-21st standard compared with 36.0% (95% CI, 27.0%-45.0%) with the US 2000...... and no significant change in the associated neonatal mortality risk, resulting in a decrease in the percentage of neonatal death attributable to SGA. Our study sheds light on how previously published studies on SGA status may be reinterpreted with the introduction of this new birth weight standard....

  20. Determining the normal range for IGF-I, IGFBP-3, and ALS: new reference data based on current internal standards.

    Science.gov (United States)

    Ertl, Diana-Alexandra; Gleiss, Andreas; Sagmeister, Susanne; Haeusler, Gabriele

    2014-09-01

    The measurement of insulin-like growth factors (IGF-I) and insulin-like growth factor-binding protein (IGFBP-3) often serves as first-line testing in children with growth disorders. The role of acid-labile subunit (ALS) as a screening parameter for homozygous or heterozygous mutations of the ALS gene still has to be determined. IGF-I, IGFBP-3, and ALS were measured in 252 samples from children and adolescents. Reference curves were fitted using generalized additive model for location, scale and shape (GAMLSS) models and SD-Scores were calculated. Bootstrap analysis was used to quantify the uncertainty of the estimated percentiles. Bland-Altman plots were used to investigate the discrepancy between our newly estimated standard deviation scores (SDS) and SDS calculated on the basis of previous reference data. We present reference data for enzyme-linked immunosorbent assay (ELISA) measurements based on recommended internal standard for IGF-I, IGFBP-3, and ALS suitable for calculation of SD-scores. The Bland-Altman plot shows a rough agreement between the previous SDS calculation and our new one only for SDS around 1; for SDS at -2, an average difference of 0.83 SD was noticed. Our IGF-I reference values for the interval of interest in diagnosing growth hormone deficiency (GHD) (prepubertal age) are solid as proved by bootstrap analysis. The difference in calculated SD scores by using data provided previously highlights the importance of using labor and method specific reference data.

  1. An Evaluation of the Sniffer Global Optimization Algorithm Using Standard Test Functions

    Science.gov (United States)

    Butler, Roger A. R.; Slaminka, Edward E.

    1992-03-01

    The performance of Sniffer—a new global optimization algorithm—is compared with that of Simulated Annealing. Using the number of function evaluations as a measure of efficiency, the new algorithm is shown to be significantly better at finding the global minimum of seven standard test functions. Several of the test functions used have many local minima and very steep walls surrounding the global minimum. Such functions are intended to thwart global minimization algorithms.

  2. Biomass-burning derived aromatic acids in NIST standard reference material 1649b and the environmental implications

    Science.gov (United States)

    Gao, Shaopeng; Xu, Baiqing; Dong, Xueling; Zheng, Xiaoyan; Wan, Xin; Kang, Shichang; Song, Qiuyin; Kawamura, Kimitaka; Cong, Zhiyuan

    2018-07-01

    Biomass burning is a serious problem in the environment and climate system. However, the source identification of biomass-burning aerosols was somewhat impeded, partly due to the difficulty in quantification of relevant molecular markers. In this study, we present reference values for five aromatic acids (including p-hydroxybenzoic, vanillic, dehydroabietic, syringic and p-coumaric acids) in the NIST Standard Reference Material (SRM) 1649b. The concentration of levoglucosan was also revisited. Notable positive matrix effect was found for vanillic, dehydroabietic, syringic and coumaric acid. Using the standard addition method, the average value of p-hydroxybenzoic, vanillic, syringic, dehydroabietic and p-coumaric acids in SRM 1649b were found to be 26.9, 9.53, 1.13, 7.60 and 1.66 μg g-1, respectively. The analytical method developed in this study was also applied to the PM10 samples from Beijing and PM2.5 samples from South Asia (Godavari, Nepal). The ratios of vanillic to p-hydroxybenzoic acid and syringic to vanillic acid further suggested that their biomass-burning types are mainly related to hard wood and herbaceous species (i.e., agricultural residues).

  3. Determination of non-ortho polychlorinated biphenyls in environmental Standard Reference Materials.

    Science.gov (United States)

    Brubaker, W W; Schantz, M M; Wise, S A

    2000-07-01

    The concentrations of three non-ortho ("coplanar") polychlorinated biphenyls, 3,3',4,4'-tetrachlorobiphenyl (IUPAC PCB 77), 3,3',4,4',5-pentachlorobiphenyl (IUPAC PCB 126), and 3,3',4,4',5,5'-hexachlorobiphenyl (IUPAC PCB 169), were determined in five NIST Standard Reference Materials (SRMs) of environmental and biological interest. The measured levels were approximately between (0.2 to 1.3) ng/g in SRM 1588a (Organics in Cod Liver Oil), (0.3 to 9) ng/g in SRM 1944 (New York/New Jersey Waterway Sediment), (0.2 to 0.4) ng/g in SRM 1945 (Organics in Whale Blubber), (1 to 18) ng/g in SRM 2974 (Organics in Freeze-dried Mussel Tissue [Mytilus edulis]), and (0.1 to 0.4) ng/g in candidate SRM 1946 (Lake Superior Fish Tissue). PCB 169 was present at < 0.1 ng/g in SRMs 1944 and 2974.

  4. IAEA nuclear data for applications: Cross section standards and the reference input parameter library (RIPL)

    International Nuclear Information System (INIS)

    Capote Noy, Roberto; Nichols, Alan L.; Pronyaev, Vladimir G.

    2003-01-01

    An integral part of the activities of the IAEA Nuclear Data Section involves the development of nuclear data for a wide range of user applications. When considering low-energy nuclear reactions induced by neutrons, photons and charged particles, a detailed knowledge is required of the production cross sections over a wide energy range, spectra of emitted particles and their angular distributions. Two highly relevant IAEA data development projects are considered in this paper. Neutron reaction cross-section standards represent the basic quantities needed in nuclear reaction cross-section measurements and evaluations. These standards and the covariance matrices of their uncertainties were previously evaluated and released in 1987. However, the derived uncertainties were subsequently considered to be unrealistic low due to the effect of the low uncertainties obtained in fitting the light element standards to the R-matrix model; as a result, evaluators were forced to scale up the uncertainties to 'expected values'. An IAEA Coordinated Research Project (CRP) entitled 'Improvement of the Standard Cross Sections for Light Elements' was initiated in 2002 to improve the evaluation methodology for the covariance matrix of uncertainty in the R-matrix model fits, and to produce R-matrix evaluations of the important light element standards. The scope of this CRP has been substantially extended to include the preparation of a full set of evaluated standard reactions and covariance matrices of their uncertainties. While almost all requests for nuclear data were originally addressed through measurement programmes, our theoretical understanding of nuclear phenomena has reached a reasonable degree of reliability and nuclear modeling has become standard practice in nuclear data evaluations (with measurements remaining crucial for data testing and benchmarking). Since nuclear model codes require a considerable amount of numerical input, the IAEA has instigated extensive efforts to

  5. Fir Filters Compliant with the IEEE Standard for M Class PMU

    Directory of Open Access Journals (Sweden)

    Duda Krzysztof

    2016-12-01

    Full Text Available In this paper it is shown that M class PMU (Phasor Measurement Unit reference model for phasor estimation recommended by the IEEE Standard C37.118.1 with the Amendment 1 is not compliant with the Standard. The reference filter preserves only the limits for TVE (total vector error, and exceeds FE (frequency error and RFE (rate of frequency error limits. As a remedy we propose new filters for phasor estimation for M class PMU that are fully compliant with the Standard requirements. The proposed filters are designed: 1 by the window method; 2 as flat-top windows; or as 3 optimal min-max filters. The results for all Standard compliance tests are presented, confirming good performance of the proposed filters. The proposed filters are fixed at the nominal frequency, i.e. frequency tracking and adaptive filter tuning are not required, therefore they are well suited for application in lowcost popular PMUs.

  6. Bias in the absorption coefficient determination of a fluorescent dye, standard reference material 1932 fluorescein solution

    International Nuclear Information System (INIS)

    DeRose, Paul C.; Kramer, Gary W.

    2005-01-01

    The absorption coefficient of standard reference material[registered] (SRM[registered]) 1932, fluorescein in a borate buffer solution (pH=9.5) has been determined at λ=488.0, 490.0, 490.5 and 491.0 nm using the US national reference UV/visible spectrophotometer. The purity of the fluorescein was determined to be 97.6% as part of the certification of SRM 1932. The solution measured was prepared gravimetrically by diluting SRM 1932 with additional borate buffer. The value of the absorption coefficient was corrected for bias due to fluorescence that reaches the detector and for dye purity. Bias due to fluorescence was found to be on the order of -1% for both monochromatic and polychromatic (e.g., diode-array based) spectrophotometers

  7. [Reference values of apolipoproteins A1 and B. Contribution of international standardization. Travail collaboratif entre la SFBC, l'Arcol et le SFRL].

    Science.gov (United States)

    Steinmetz, J; Caces, E; Couderc, R; Beucler, I; Legrand, A; Henny, J

    1997-01-01

    The utilization of two WHO reference materials, liquid and lyophilized, permitted international standardization of apolipoprotein measurements. We report here the results of a collaborative study between Arcol, SFBC and SFRL in order to establish reference ranges for apo A1 and B on nine standardized systems. A population of 1027 men and women supposed healthy, 4 to 60 year old, have been selected in two Centers for Preventive Medicine. The serum samples were aliquoted frozen at -20 degrees C the day of sampling and analysed by the manufacturers with IFCC standardized calibrants. A specific quality control was performed using a frozen pool of sera. For apo A1, the centile 2.5 of the reference population varies from 1.04 to 1.16 g/l. The range values for the centile 97.5 varies from 1.87 to 2.24 g/l. For apoB, the centile 2.5 varies from 0.43 to 0.57 g/l, and the centile 97.5 from 1.30 to 1.39 g/l. Only one system has a problem of dispersion with an upper limit equal to 1.20 g/l. These results improve that international standardization allowed actually a good comparability of the results, especially for apoB.

  8. Availability of color calibration for consistent color display in medical images and optimization of reference brightness for clinical use

    Science.gov (United States)

    Iwai, Daiki; Suganami, Haruka; Hosoba, Minoru; Ohno, Kazuko; Emoto, Yutaka; Tabata, Yoshito; Matsui, Norihisa

    2013-03-01

    Color image consistency has not been accomplished yet except the Digital Imaging and Communication in Medicine (DICOM) Supplement 100 for implementing a color reproduction pipeline and device independent color spaces. Thus, most healthcare enterprises could not check monitor degradation routinely. To ensure color consistency in medical color imaging, monitor color calibration should be introduced. Using simple color calibration device . chromaticity of colors including typical color (Red, Green, Blue, Green and White) are measured as device independent profile connection space value called u'v' before and after calibration. In addition, clinical color images are displayed and visual differences are observed. In color calibration, monitor brightness level has to be set to quite lower value 80 cd/m2 according to sRGB standard. As Maximum brightness of most color monitors available currently for medical use have much higher brightness than 80 cd/m2, it is not seemed to be appropriate to use 80 cd/m2 level for calibration. Therefore, we propose that new brightness standard should be introduced while maintaining the color representation in clinical use. To evaluate effects of brightness to chromaticity experimentally, brightness level is changed in two monitors from 80 to 270cd/m2 and chromaticity value are compared with each brightness levels. As a result, there are no significant differences in chromaticity diagram when brightness levels are changed. In conclusion, chromaticity is close to theoretical value after color calibration. Moreover, chromaticity isn't moved when brightness is changed. The results indicate optimized reference brightness level for clinical use could be set at high brightness in current monitors .

  9. Selection of References in Wind Turbine Model Predictive Control Design

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Hovgaard, Tobias

    2015-01-01

    a model predictive controller for a wind turbine. One of the important aspects for a tracking control problem is how to setup the optimal reference tracking problem, as it might be relevant to track, e.g., the three concurrent references: optimal pitch angle, optimal rotational speed, and optimal power......Lowering the cost of energy is one of the major focus areas in the wind turbine industry. Recent research has indicated that wind turbine controllers based on model predictive control methods can be useful in obtaining this objective. A number of design considerations have to be made when designing....... The importance if the individual references differ depending in particular on the wind speed. In this paper we investigate the performance of a reference tracking model predictive controller with two different setups of the used optimal reference signals. The controllers are evaluated using an industrial high...

  10. Design and realization of the high-precision weighing systems as the gravimetric references in PTB's national water flow standard

    International Nuclear Information System (INIS)

    Engel, Rainer; Beyer, Karlheinz; Baade, Hans-Joachim

    2012-01-01

    PTB's ‘Hydrodynamic Test Field’, which represents a high-accuracy water flow calibration facility, serves as the national primary standard for liquid flow measurands. As the core reference device of this flow facility, a gravimetric standard has been incorporated, which comprises three special-design weighing systems: 300 kg, 3 tons and 30 tons. These gravimetric references were realized as a combination of a strain-gauge-based and an electromagnetic-force-compensation load-cell-based balance, each. Special emphasis had to be placed upon the dynamics design of the whole weighing system, due to the high measurement resolution and the dynamic behavior of the weighing systems, which are dynamically affected by mechanical vibrations caused by environmental impacts, flow machinery operation, flow noise in the pipework and induced wave motions in the weigh tanks. Taking into account all the above boundary conditions, the design work for the gravimetric reference resulted in a concrete foundation ‘rock’ of some 300 tons that rests on a number of vibration isolators. In addition to these passively operating vibration isolators, the vibration damping effect is enhanced by applying an electronic level regulation device. (paper)

  11. Optimal set of selected uranium enrichments that minimizes blending consequences

    International Nuclear Information System (INIS)

    Nachlas, J.A.; Kurstedt, H.A. Jr.; Lobber, J.S. Jr.

    1977-01-01

    Identities, quantities, and costs associated with producing a set of selected enrichments and blending them to provide fuel for existing reactors are investigated using an optimization model constructed with appropriate constraints. Selected enrichments are required for either nuclear reactor fuel standardization or potential uranium enrichment alternatives such as the gas centrifuge. Using a mixed-integer linear program, the model minimizes present worth costs for a 39-product-enrichment reference case. For four ingredients, the marginal blending cost is only 0.18% of the total direct production cost. Natural uranium is not an optimal blending ingredient. Optimal values reappear in most sets of ingredient enrichments

  12. Application of air traffic control competence reference models as a mean of air navigation services provider’s charge optimization

    Directory of Open Access Journals (Sweden)

    В.П. Харченко

    2010-01-01

    Full Text Available  The issue of application of Air Traffic Control (ATC competence reference models as a mean of air navigation services provider’s charge optimization is described in the article, and this issue is interpretated as an optimization task. The data relating to the significant growth of aviation traffic, especially using the airspace of Ukraine, given by authors, and the statement of fact that Air Traffic Management (ATM system’s technical component reliability increasement takes place on the basis of practically invariable psychophysiological abilities of aviation controller, make the substantiation of ANSP provision with the most trained ATC controllers for the work on the working places of ATC Unit actual. The ‘mechanism’ of ATC controllers competence reference model creation is defined step-by step. There is an example of candidate’s for the working place competence quantitative individual model forming as a common criteria of competence, which, in its turn, is the compressed format of all parameters of its working activity, received at the stage of control. The approach, according to which the individual parameters of graduating student’s output model’s professional characteristics, which he received after the examination of his work as Tower controller (ATM Unit of aerodrome control service, approach controller or area control service controller, are compared with the predetermined specialist’s competence reference model, relating to the special working place in ATM system, is supposed here. Notably, the conception, relating to the correspondence of the graduating student’s competence output level to the defined reference model of ATC controller, relating to the special working place of ATM Unit, is realised.

  13. A height-for-age growth reference for children with achondroplasia: Expanded applications and comparison with original reference data.

    Science.gov (United States)

    Hoover-Fong, Julie; McGready, John; Schulze, Kerry; Alade, Adekemi Yewande; Scott, Charles I

    2017-05-01

    The height-for-age (HA) reference currently used for children with achondroplasia is not adaptable for electronic records or calculation of HA Z-scores. We report new HA curves and tables of mean and standard deviation (SD) HA, for calculating Z-scores, from birth-16 years in achondroplasia. Mixed longitudinal data were abstracted from medical records of achondroplasia patients from a single clinical practice (CIS, 1967-2004). Gender-specific height percentiles (5, 25, 50, 75, 95th) were estimated across the age continuum, using a 2 month window per time point smoothed by a quadratic smoothing algorithm. HA curves were constructed for 0-36 months and 2-16 years to optimize resolution for younger children. Mean monthly height (SD) was tabulated. These novel HA curves were compared to reference data currently in use for children with achondroplasia. 293 subjects (162 male/131 female) contributed 1,005 and 932 height measures, with greater data paucity with age. Mean HA tracked with original achondroplasia norms, particularly through mid-childhood (2-9 years), but with no evidence of a pubertal growth spurt. Standard deviation of height at each month interval increased from birth through 16 years. Birth length was lower in achondroplasia than average stature and, as expected, height deficits increased with age. A new HA reference is available for longitudinal growth assessment in achondroplasia, taking advantage of statistical modeling techniques and allowing for Z-score calculations. This is an important contribution to clinical care and research endeavors for the achondroplasia population. © 2017 Wiley Periodicals, Inc.

  14. Determinations of silicon and phosphorus in Pepperbush standard reference material by neutron activation and x-ray fluorescence methods

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Nishio, Hirofumi; Hayashi, Takeshi; Kusakabe, Toshio; Iwata, Shiro.

    1987-01-01

    Silicon and phosphorus contents in Pepperbush standard reference material were determined by neutron activation and X-ray fluorescence methods. In neutron activation analysis, β-ray spectra of 32 P produced by 31 P(n,γ) 32 P reaction on Pepperbush and standard samples were measured by a low background β-ray spectrometer. In X-ray fluorescence analysis, the standard samples were prepared by mixing the Pepperbush powder with silicon dioxide and diammonium hydrogenphosphate. Characteristic X-rays from the samples were analyzed by a wavelength dispersive X-ray fluorescence spectrometer. From the β and X-ray intensities, silicon and phosphorus contents in Pepperbush were determined to be 1840 ± 80 and 1200 ± 50 μg g -1 , respectively. (author)

  15. Correlation pattern recognition: optimal parameters for quality standards control of chocolate marshmallow candy

    Science.gov (United States)

    Flores, Jorge L.; García-Torales, G.; Ponce Ávila, Cristina

    2006-08-01

    This paper describes an in situ image recognition system designed to inspect the quality standards of the chocolate pops during their production. The essence of the recognition system is the localization of the events (i.e., defects) in the input images that affect the quality standards of pops. To this end, processing modules, based on correlation filter, and segmentation of images are employed with the objective of measuring the quality standards. Therefore, we designed the correlation filter and defined a set of features from the correlation plane. The desired values for these parameters are obtained by exploiting information about objects to be rejected in order to find the optimal discrimination capability of the system. Regarding this set of features, the pop can be correctly classified. The efficacy of the system has been tested thoroughly under laboratory conditions using at least 50 images, containing 3 different types of possible defects.

  16. Wireless Sensor Network Congestion Control Based on Standard Particle Swarm Optimization and Single Neuron PID.

    Science.gov (United States)

    Yang, Xiaoping; Chen, Xueying; Xia, Riting; Qian, Zhihong

    2018-04-19

    Aiming at the problem of network congestion caused by the large number of data transmissions in wireless routing nodes of wireless sensor network (WSN), this paper puts forward an algorithm based on standard particle swarm⁻neural PID congestion control (PNPID). Firstly, PID control theory was applied to the queue management of wireless sensor nodes. Then, the self-learning and self-organizing ability of neurons was used to achieve online adjustment of weights to adjust the proportion, integral and differential parameters of the PID controller. Finally, the standard particle swarm optimization to neural PID (NPID) algorithm of initial values of proportion, integral and differential parameters and neuron learning rates were used for online optimization. This paper describes experiments and simulations which show that the PNPID algorithm effectively stabilized queue length near the expected value. At the same time, network performance, such as throughput and packet loss rate, was greatly improved, which alleviated network congestion and improved network QoS.

  17. Wireless Sensor Network Congestion Control Based on Standard Particle Swarm Optimization and Single Neuron PID

    Science.gov (United States)

    Yang, Xiaoping; Chen, Xueying; Xia, Riting; Qian, Zhihong

    2018-01-01

    Aiming at the problem of network congestion caused by the large number of data transmissions in wireless routing nodes of wireless sensor network (WSN), this paper puts forward an algorithm based on standard particle swarm–neural PID congestion control (PNPID). Firstly, PID control theory was applied to the queue management of wireless sensor nodes. Then, the self-learning and self-organizing ability of neurons was used to achieve online adjustment of weights to adjust the proportion, integral and differential parameters of the PID controller. Finally, the standard particle swarm optimization to neural PID (NPID) algorithm of initial values of proportion, integral and differential parameters and neuron learning rates were used for online optimization. This paper describes experiments and simulations which show that the PNPID algorithm effectively stabilized queue length near the expected value. At the same time, network performance, such as throughput and packet loss rate, was greatly improved, which alleviated network congestion and improved network QoS. PMID:29671822

  18. Updating OSHA standards based on national consensus standards. Direct final rule.

    Science.gov (United States)

    2007-12-14

    In this direct final rule, the Agency is removing several references to consensus standards that have requirements that duplicate, or are comparable to, other OSHA rules; this action includes correcting a paragraph citation in one of these OSHA rules. The Agency also is removing a reference to American Welding Society standard A3.0-1969 ("Terms and Definitions") in its general-industry welding standards. This rulemaking is a continuation of OSHA's ongoing effort to update references to consensus and industry standards used throughout its rules.

  19. Hot and cold body reference noise generators from 0 to 40 GHz

    Science.gov (United States)

    Hornbostel, D. H.

    1974-01-01

    This article describes the design, development, and analysis of exceptionally accurate radiometric noise generators from 0-40 GHz to serve as standard references. Size, weight, power, and reliability are optimized to meet the requirements of NASA air- and space-borne radiometers. The radiometric noise temperature of these noise generators is, unavoidably, calculated from measured values rather than measured directly. The absolute accuracy and stability are equal to or better than those of reliable standards available for comparison. A noise generator has been developed whose measurable properties (VSWR, line loss, thermometric temperatures) have been optimized in order to minimize the effects of the uncertainty in the calculated radiometric noise temperatures. Each measurable property is evaluated and analyzed to determine the effects of the uncertainty of the measured value. Unmeasurable properties (primarily temperature gradients) are analyzed, and reasonable precautions are designed into the noise generator to guarantee that the uncertainty of the value remains within tolerable limits.

  20. The uncertainty of reference standards--a guide to understanding factors impacting uncertainty, uncertainty calculations, and vendor certifications.

    Science.gov (United States)

    Gates, Kevin; Chang, Ning; Dilek, Isil; Jian, Huahua; Pogue, Sherri; Sreenivasan, Uma

    2009-10-01

    Certified solution standards are widely used in forensic toxicological, clinical/diagnostic, and environmental testing. Typically, these standards are purchased as ampouled solutions with a certified concentration. Vendors present concentration and uncertainty differently on their Certificates of Analysis. Understanding the factors that impact uncertainty and which factors have been considered in the vendor's assignment of uncertainty are critical to understanding the accuracy of the standard and the impact on testing results. Understanding these variables is also important for laboratories seeking to comply with ISO/IEC 17025 requirements and for those preparing reference solutions from neat materials at the bench. The impact of uncertainty associated with the neat material purity (including residual water, residual solvent, and inorganic content), mass measurement (weighing techniques), and solvent addition (solution density) on the overall uncertainty of the certified concentration is described along with uncertainty calculations.

  1. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  2. Identification of suitable reference genes for gene expression studies of shoulder instability.

    Directory of Open Access Journals (Sweden)

    Mariana Ferreira Leal

    Full Text Available Shoulder instability is a common shoulder injury, and patients present with plastic deformation of the glenohumeral capsule. Gene expression analysis may be a useful tool for increasing the general understanding of capsule deformation, and reverse-transcription quantitative polymerase chain reaction (RT-qPCR has become an effective method for such studies. Although RT-qPCR is highly sensitive and specific, it requires the use of suitable reference genes for data normalization to guarantee meaningful and reproducible results. In the present study, we evaluated the suitability of a set of reference genes using samples from the glenohumeral capsules of individuals with and without shoulder instability. We analyzed the expression of six commonly used reference genes (ACTB, B2M, GAPDH, HPRT1, TBP and TFRC in the antero-inferior, antero-superior and posterior portions of the glenohumeral capsules of cases and controls. The stability of the candidate reference gene expression was determined using four software packages: NormFinder, geNorm, BestKeeper and DataAssist. Overall, HPRT1 was the best single reference gene, and HPRT1 and B2M composed the best pair of reference genes from different analysis groups, including simultaneous analysis of all tissue samples. GenEx software was used to identify the optimal number of reference genes to be used for normalization and demonstrated that the accumulated standard deviation resulting from the use of 2 reference genes was similar to that resulting from the use of 3 or more reference genes. To identify the optimal combination of reference genes, we evaluated the expression of COL1A1. Although the use of different reference gene combinations yielded variable normalized quantities, the relative quantities within sample groups were similar and confirmed that no obvious differences were observed when using 2, 3 or 4 reference genes. Consequently, the use of 2 stable reference genes for normalization, especially

  3. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    Science.gov (United States)

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  4. An administrative data validation study of the accuracy of algorithms for identifying rheumatoid arthritis: the influence of the reference standard on algorithm performance.

    Science.gov (United States)

    Widdifield, Jessica; Bombardier, Claire; Bernatsky, Sasha; Paterson, J Michael; Green, Diane; Young, Jacqueline; Ivers, Noah; Butt, Debra A; Jaakkimainen, R Liisa; Thorne, J Carter; Tu, Karen

    2014-06-23

    We have previously validated administrative data algorithms to identify patients with rheumatoid arthritis (RA) using rheumatology clinic records as the reference standard. Here we reassessed the accuracy of the algorithms using primary care records as the reference standard. We performed a retrospective chart abstraction study using a random sample of 7500 adult patients under the care of 83 family physicians contributing to the Electronic Medical Record Administrative data Linked Database (EMRALD) in Ontario, Canada. Using physician-reported diagnoses as the reference standard, we computed and compared the sensitivity, specificity, and predictive values for over 100 administrative data algorithms for RA case ascertainment. We identified 69 patients with RA for a lifetime RA prevalence of 0.9%. All algorithms had excellent specificity (>97%). However, sensitivity varied (75-90%) among physician billing algorithms. Despite the low prevalence of RA, most algorithms had adequate positive predictive value (PPV; 51-83%). The algorithm of "[1 hospitalization RA diagnosis code] or [3 physician RA diagnosis codes with ≥1 by a specialist over 2 years]" had a sensitivity of 78% (95% CI 69-88), specificity of 100% (95% CI 100-100), PPV of 78% (95% CI 69-88) and NPV of 100% (95% CI 100-100). Administrative data algorithms for detecting RA patients achieved a high degree of accuracy amongst the general population. However, results varied slightly from our previous report, which can be attributed to differences in the reference standards with respect to disease prevalence, spectrum of disease, and type of comparator group.

  5. Establishing the traceability of a uranyl nitrate solution to a standard reference material

    International Nuclear Information System (INIS)

    Jackson, C.H.; Clark, J.P.

    1978-01-01

    A uranyl nitrate solution for use as a Working Calibration and Test Material (WCTM) was characterized, using a statistically designed procedure to document traceability to National Bureau of Standards Reference Material (SPM-960). A Reference Calibration and Test Material (PCTM) was prepared from SRM-960 uranium metal to approximate the acid and uranium concentration of the WCTM. This solution was used in the characterization procedure. Details of preparing, handling, and packaging these solutions are covered. Two outside laboratories, each having measurement expertise using a different analytical method, were selected to measure both solutions according to the procedure for characterizing the WCTM. Two different methods were also used for the in-house characterization work. All analytical results were tested for statistical agreement before the WCTM concentration and limit of error values were calculated. A concentration value was determined with a relative limit of error (RLE) of approximately 0.03% which was better than the target RLE of 0.08%. The use of this working material eliminates the expense of using SRMs to fulfill traceability requirements for uranium measurements on this type material. Several years' supply of uranyl nitrate solution with NBS traceability was produced. The cost of this material was less than 10% of an equal quantity of SRM-960 uranium metal

  6. Standard Test Method for Calibration of Non-Concentrator Photovoltaic Secondary Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers calibration and characterization of secondary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device. 1.2 Secondary reference cells are calibrated indoors using simulated sunlight or outdoors in natural sunlight by reference to a primary reference cell previously calibrated to the same desired reference spectral irradiance distribution. 1.3 Secondary reference cells calibrated according to this test method will have the same radiometric traceability as the of the primary reference cell used for the calibration. Therefore, if the primary reference cell is traceable to the World Radiometric Reference (WRR, see Test Method E816), the resulting secondary reference cell will also be traceable to the WRR. 1.4 This test method appli...

  7. The development and certification of Standard Reference Materials (SRMs) to assess and ensure accurate measurement of Pb in the environment.

    Science.gov (United States)

    Fassett, J D; MacDonald, B S

    2001-08-01

    The National Institute of Standards and Technology (NIST) has had a major quality-assurance role in the federal effort to reduce lead poisoning of children in the United States through its mission of ensuring the accuracy of chemical measurements. NIST certifies reference materials (standard reference materials--SRMs) that are used to benchmark measurements by secondary and field methods of analysis--to ensure that decisions of great health and economic impact are soundly based on good measurement science. Over the past 10 years, in cooperation with the US Environmental Protection Agency (EPA), US Department of Housing and Urban Development (HUD), and the United States Geological Survey (USGS), NIST has prepared and certified SRMs for lead content in soil, indoor dust, and paint. The role of these materials in meeting regulatory and abatement needs is described and their certified values are summarized.

  8. Optimal transformations leading to normal distributions of positron emission tomography standardized uptake values

    Science.gov (United States)

    Scarpelli, Matthew; Eickhoff, Jens; Cuna, Enrique; Perlman, Scott; Jeraj, Robert

    2018-02-01

    The statistical analysis of positron emission tomography (PET) standardized uptake value (SUV) measurements is challenging due to the skewed nature of SUV distributions. This limits utilization of powerful parametric statistical models for analyzing SUV measurements. An ad-hoc approach, which is frequently used in practice, is to blindly use a log transformation, which may or may not result in normal SUV distributions. This study sought to identify optimal transformations leading to normally distributed PET SUVs extracted from tumors and assess the effects of therapy on the optimal transformations. Methods. The optimal transformation for producing normal distributions of tumor SUVs was identified by iterating the Box-Cox transformation parameter (λ) and selecting the parameter that maximized the Shapiro-Wilk P-value. Optimal transformations were identified for tumor SUVmax distributions at both pre and post treatment. This study included 57 patients that underwent 18F-fluorodeoxyglucose (18F-FDG) PET scans (publically available dataset). In addition, to test the generality of our transformation methodology, we included analysis of 27 patients that underwent 18F-Fluorothymidine (18F-FLT) PET scans at our institution. Results. After applying the optimal Box-Cox transformations, neither the pre nor the post treatment 18F-FDG SUV distributions deviated significantly from normality (P  >  0.10). Similar results were found for 18F-FLT PET SUV distributions (P  >  0.10). For both 18F-FDG and 18F-FLT SUV distributions, the skewness and kurtosis increased from pre to post treatment, leading to a decrease in the optimal Box-Cox transformation parameter from pre to post treatment. There were types of distributions encountered for both 18F-FDG and 18F-FLT where a log transformation was not optimal for providing normal SUV distributions. Conclusion. Optimization of the Box-Cox transformation, offers a solution for identifying normal SUV transformations for when

  9. X-ray holography with a customizable reference.

    Science.gov (United States)

    Martin, Andrew V; D'Alfonso, Adrian J; Wang, Fenglin; Bean, Richard; Capotondi, Flavio; Kirian, Richard A; Pedersoli, Emanuele; Pedersoli, Emmanuele; Raimondi, Lorenzo; Stellato, Francesco; Yoon, Chun Hong; Chapman, Henry N

    2014-08-22

    In X-ray Fourier-transform holography, images are formed by exploiting the interference pattern between the X-rays scattered from the sample and a known reference wave. To date, this technique has only been possible with a limited set of special reference waves. We demonstrate X-ray Fourier-transform holography with an almost unrestricted choice for the reference wave, permitting experimental geometries to be designed according to the needs of each experiment and opening up new avenues to optimize signal-to-noise and resolution. The optimization of holographic references can aid the development of holographic techniques to meet the demands of resolution and fidelity required for single-shot imaging applications with X-ray lasers.

  10. Standardization and Optimization of Computed Tomography Protocols to Achieve Low-Dose

    Science.gov (United States)

    Chin, Cynthia; Cody, Dianna D.; Gupta, Rajiv; Hess, Christopher P.; Kalra, Mannudeep K.; Kofler, James M.; Krishnam, Mayil S.; Einstein, Andrew J.

    2014-01-01

    The increase in radiation exposure due to CT scans has been of growing concern in recent years. CT scanners differ in their capabilities and various indications require unique protocols, but there remains room for standardization and optimization. In this paper we summarize approaches to reduce dose, as discussed in lectures comprising the first session of the 2013 UCSF Virtual Symposium on Radiation Safety in Computed Tomography. The experience of scanning at low dose in different body regions, for both diagnostic and interventional CT procedures, is addressed. An essential primary step is justifying the medical need for each scan. General guiding principles for reducing dose include tailoring a scan to a patient, minimizing scan length, use of tube current modulation and minimizing tube current, minimizing-tube potential, iterative reconstruction, and periodic review of CT studies. Organized efforts for standardization have been spearheaded by professional societies such as the American Association of Physicists in Medicine. Finally, all team members should demonstrate an awareness of the importance of minimizing dose. PMID:24589403

  11. Crystal structure of isopropyl 2-hydroxy-2-phenylacetate: a pharmacopoeia reference standard

    Directory of Open Access Journals (Sweden)

    Ivan Isaiev

    2017-05-01

    Full Text Available The title compound, C11H14O3, is used as a pharmacopoeia reference standard for determining impurities in the drug Pregabalin, used for the treatment of epilepsy and diabetic neuropathic pain. The molecule is far from being planar, with the dihedral angle between the planes of the aromatic ring and the carboxyl fragment (O—C=O being 76.1 (6°. The isopropyl substituent is located in a synperiplanar position relative to the C=O bond and is turned so that the C—O—C—H torsion angle is −43.7°. In the crystal, bifurcated O—H...(O,O hydrogen bonds, enclosing R12(5 ring motifs, lead to the formation of chains propagating along the c-axis direction. Inversion-related chains are linked by the C—H...O hydrogen bonds, forming undulating layers lying parallel to the bc plane.

  12. Reduction of cancer risk by optimization of Computed Tomography head protocols: far eastern Cuban experience

    International Nuclear Information System (INIS)

    Miller Clemente, R.; Adame Brooks, D.; Lores Guevara, M.; Perez Diaz, M.; Arias Garlobo, M. L.; Ortega Rodriguez, O.; Nepite Haber, R.; Grinnan Hernandez, O.; Guillama Llosas, A.

    2015-01-01

    The cancer risk estimation constitutes one way for the evaluation of the public health, regarding computed tomography (CT) exposures. Starting from the hypothesis that the optimization of CT protocols would reduce significantly the added cancer risk, the purpose of this research was the application of optimization strategies regarding head CT protocols, in order to reduce the factors affecting the risk of induced cancer. The applied systemic approach included technological and human components, represented by quantitative physical factors. the volumetric kerma indexes, compared with respect to standard, optimized and reference values, were evaluated with multiple means comparison method. The added cancer risk resulted from the application of the methodology for biological effects evaluation, at low doses with low Linear Energy Transfer. Human observers in all scenarios evaluated the image quality. the reduced dose was significantly lower than for standard head protocols and reference levels, where: (1) for pediatric patients, by using an Automatic Exposure Control system, a reduction of 31% compared with standard protocol and ages range of 10-14, and (2) adults, using a Bilateral Filter for images obtained at low doses of 62% from those of standard head protocol. The risk reduction was higher than 25%. The systemic approach used allows the effective identification of factors involved on cancer risk related with exposures to CT. The combination of dose modulation and image restoration with Bilateral Filter, provide a significantly reduction of cancer risk, with acceptable diagnostic image quality. (Author)

  13. Standard Relativistic Reference Systems and the IAU Framework

    Science.gov (United States)

    Soffel, Michael H.

    2009-05-01

    The classical post-Newtonian (PN) framework is formulated in one single reference system. In a series of papers Damour, Soffel and Xu laid the foundations for a new improved PN framework dealing with the celestial mechanical problem of N gravitationally interacting rotating bodies of arbitrary shape and the problem of astronomical reference systems. In the DSX-framework a total of N+1 reference systems with corresponding coordinates is introduced in the N-body problem: a global one covering the entire model manifold where the translational equations of motion are formulated and one local system attached to each of the N bodies that is co-moving with the body under consideration. In each of these systems the metric tensor is assumed to be of a special form determined by two potentials: a scalar and a vector potential. Theorems are given for the transformations between local and global coordinates and metric potentials. In each of the local systems outside the local body the metric potentials are expressed in terms of Blanchet-Damour mass- and spin-multipole moments. The talk first introduces the original DSX formalism and then concentrates on IAU resolutions related with it. Finally, the formalism is extended to include also effects from the cosmic expansion. The influence of the Hubble expansion on the dynamics of the solar system is explicitly discussed in some detail.

  14. Multiparameter optimization of mammography: an update

    Science.gov (United States)

    Jafroudi, Hamid; Muntz, E. P.; Jennings, Robert J.

    1994-05-01

    Previously in this forum we have reported the application of multiparameter optimization techniques to the design of a minimum dose mammography system. The approach used a reference system to define the physical imaging performance required and the dose to which the dose for the optimized system should be compared. During the course of implementing the resulting design in hardware suitable for laboratory testing, the state of the art in mammographic imaging changed, so that the original reference system, which did not have a grid, was no longer appropriate. A reference system with a grid was selected in response to this change, and at the same time the optimization procedure was modified, to make it more general and to facilitate study of the optimized design under a variety of conditions. We report the changes in the procedure, and the results obtained using the revised procedure and the up- to-date reference system. Our results, which are supported by laboratory measurements, indicate that the optimized design can image small objects as well as the reference system using only about 30% of the dose required by the reference system. Hardware meeting the specification produced by the optimization procedure and suitable for clinical use is currently under evaluation in the Diagnostic Radiology Department at the Clinical Center, NH.

  15. Determination of 25 elements in biological standard reference materials by neutron activation analysis

    International Nuclear Information System (INIS)

    Guzzi, G.; Pietra, R.; Sabbioni, E.

    1974-12-01

    Standard and Certified Reference Materials programme of the JRC includes the determination of trace elements in complex biological samples delivered by the U.S. National Bureau of Standards: Bovine liver (NBS SRM 1577), Orchard Leaves (NBS SRM 1571) and Tomato Leaves. The study has been performed by the use of neutron activation analysis. Due to the very low concentration of some elements, radiochemical groups or elemental separation procedures were necessary. The paper describes the techniques used to analyse 25 elements. Computer assisted instrumental neutron activation analysis with high resolution Ge(Li) spectrometry was considerably advantageous in the determination of Na, K, Cl, Mn, Fe, Rb and Co and in some cases of Ca, Zn, Cs, Sc, and Cr. For low contents of Ca, Mg, Ni and Si special chemical separation schemes, followed by Cerenkov counting have been developped. Two other separation procedures allowing the determination of As, Cd, Ga, Hg, Mo, Cu, Sr Se, Ba and P have been set up. The first, the simplified one involves the use of high resolution Ge(Li) detectors, the second, the more complete one involves a larger number of shorter measurements performed by simpler and more sensitive techniques, such as NaI(Tl) scintillation spectrometry and Cerenkov counting. The results obtained are presented and discussed

  16. Crew awareness as key to optimizing habitability standards onboard naval platforms: A 'back-to-basics' approach.

    Science.gov (United States)

    Neelakantan, Anand; Ilankumaran, Mookkiah; Ray, Sougat

    2017-10-01

    A healthy habitable environment onboard warships is vital to operational fleet efficiency and fit sea-warrier force. Unique man-machine-armament interface issues and consequent constraints on habitability necessitate a multi-disciplinary approach toward optimizing habitability standards. Study of the basic 'human factor', including crew awareness on what determines shipboard habitability, and its association with habitation specifications is an essential step in such an approach. The aim of this study was to assess crew awareness on shipboard habitability and the association between awareness and maintenance of optimal habitability as per specifications. A cross-sectional descriptive study was carried out among 552 naval personnel onboard warships in Mumbai. Data on crew awareness on habitability was collected using a standardized questionnaire, and correlated with basic habitability requirement specifications. Data was analyzed using Microsoft Excel, Epi-info, and SPSS version 17. Awareness level on basic habitability aspects was very good in 65.3% of crew. Area-specific awareness was maximum with respect to living area (95.3%). Knowledge levels on waste management were among the lowest (65.2%) in the category of aspect-wise awareness. Statistically significant association was found between awareness levels and habitability standards (OR = 7.27). The new benchmarks set in the form of high crew awareness levels on basic shipboard habitability specifications and its significant association with standards needs to be sustained. It entails re-iteration of healthy habitation essentials into training; and holds the key to a fit fighting force.

  17. Optimal Reference Genes for Gene Expression Normalization in Trichomonas vaginalis

    Science.gov (United States)

    dos Santos, Odelta; de Vargas Rigo, Graziela; Frasson, Amanda Piccoli; Macedo, Alexandre José; Tasca, Tiana

    2015-01-01

    Trichomonas vaginalis is the etiologic agent of trichomonosis, the most common non-viral sexually transmitted disease worldwide. This infection is associated with several health consequences, including cervical and prostate cancers and HIV acquisition. Gene expression analysis has been facilitated because of available genome sequences and large-scale transcriptomes in T. vaginalis, particularly using quantitative real-time polymerase chain reaction (qRT-PCR), one of the most used methods for molecular studies. Reference genes for normalization are crucial to ensure the accuracy of this method. However, to the best of our knowledge, a systematic validation of reference genes has not been performed for T. vaginalis. In this study, the transcripts of nine candidate reference genes were quantified using qRT-PCR under different cultivation conditions, and the stability of these genes was compared using the geNorm and NormFinder algorithms. The most stable reference genes were α-tubulin, actin and DNATopII, and, conversely, the widely used T. vaginalis reference genes GAPDH and β-tubulin were less stable. The PFOR gene was used to validate the reliability of the use of these candidate reference genes. As expected, the PFOR gene was upregulated when the trophozoites were cultivated with ferrous ammonium sulfate when the DNATopII, α-tubulin and actin genes were used as normalizing gene. By contrast, the PFOR gene was downregulated when the GAPDH gene was used as an internal control, leading to misinterpretation of the data. These results provide an important starting point for reference gene selection and gene expression analysis with qRT-PCR studies of T. vaginalis. PMID:26393928

  18. The standardisation of trace elements in international biological standard reference materials with neutron activation analysis and atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Pieterse, H.

    1981-12-01

    An investigation was undertaken into the analytical procedures and the identification of problem areas, for the certification of a new biological standard reference material supplied by the International Atomic Energy Agency, namely, a human hair sample designated as HH-I. The analyses comprised the determination of the elements As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Sb, Se, and Zn in the hair sample by using two analytical techniques, namely, Instrumental Neutron Activation Analysis and Atomic Absorption. Three other certified biological reference materials, namely, Orchard Leaves (ORCH-L), Sea Plant Material (SPM-I) and Copepod (MAA-I) were used as control standards. Determinations were made of the moisture content of the samples, using varying conditions of drying, and the necessary corrections were applied to all analytical results so that the final elemental values related to dry weight of samples. Attention was also given to the possible loss of specific elements during ashing of the samples prior to the actual instrumental analysis. The results obtained for the hair sample by the two techniques were in good agreement for the elements Co, Fe, Mn, and Zn, but did not agree for the elements Cr and Sb. As, Hg and Se could only be determined with Instrumental Neutron Activation Analysis, and Cd, Cu and Ni only with Atomic Absorption. Most of the results obtained for the three control standard reference materials were within the ranges specified for the individual elements in each sample. The analytical procedures used for determining Cd, Cr, Cu, Ni and Sb with Instrumental Neutron Activation Analysis and As, Cr, Sb and Se with Atomic Absorption, need further investigation. The measurement of the moisture content and the ashing of samples also require further investigation with a view to improving accuracy

  19. Identification of Optimal Reference Genes for Normalization of qPCR Analysis during Pepper Fruit Development

    Directory of Open Access Journals (Sweden)

    Yuan Cheng

    2017-06-01

    Full Text Available Due to its high sensitivity and reproducibility, quantitative real-time PCR (qPCR is practiced as a useful research tool for targeted gene expression analysis. For qPCR operations, the normalization with suitable reference genes (RGs is a crucial step that eventually determines the reliability of the obtained results. Although pepper is considered an ideal model plant for the study of non-climacteric fruit development, at present no specific RG have been developed or validated for the qPCR analyses of pepper fruit. Therefore, this study aimed to identify stably expressed genes for their potential use as RGs in pepper fruit studies. Initially, a total of 35 putative RGs were selected by mining the pepper transcriptome data sets derived from the PGP (Pepper Genome Platform and PGD (Pepper Genome Database. Their expression stabilities were further measured in a set of pepper (Capsicum annuum L. var. 007e fruit samples, which represented four different fruit developmental stages (IM: Immature; MG: Mature green; B: Break; MR: Mature red using the qPCR analysis. Then, based on the qPCR results, three different statistical algorithms, namely geNorm, Normfinder, and boxplot, were chosen to evaluate the expression stabilities of these putative RGs. It should be noted that nine genes were proven to be qualified as RGs during pepper fruit development, namely CaREV05 (CA00g79660; CaREV08 (CA06g02180; CaREV09 (CA06g05650; CaREV16 (Capana12g002666; CaREV21 (Capana10g001439; CaREV23 (Capana05g000680; CaREV26 (Capana01g002973; CaREV27 (Capana11g000123; CaREV31 (Capana04g002411; and CaREV33 (Capana08g001826. Further analysis based on geNorm suggested that the application of the two most stably expressed genes (CaREV05 and CaREV08 would provide optimal transcript normalization in the qPCR experiments. Therefore, a new and comprehensive strategy for the identification of optimal RGs was developed. This strategy allowed for the effective normalization of the q

  20. Method for Determining Optimal Residential Energy Efficiency Retrofit Packages

    Energy Technology Data Exchange (ETDEWEB)

    Polly, B.; Gestwick, M.; Bianchi, M.; Anderson, R.; Horowitz, S.; Christensen, C.; Judkoff, R.

    2011-04-01

    Businesses, government agencies, consumers, policy makers, and utilities currently have limited access to occupant-, building-, and location-specific recommendations for optimal energy retrofit packages, as defined by estimated costs and energy savings. This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example, applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location. Energy savings and incremental costs are calculated relative to a minimum upgrade reference scenario, which accounts for efficiency upgrades that would occur in the absence of a retrofit because of equipment wear-out and replacement with current minimum standards.

  1. Instant standard concept for data standards development

    NARCIS (Netherlands)

    Folmer, Erwin Johan Albert; Kulcsor, Istvan Zsolt; Roes, Jasper

    2013-01-01

    This paper presents the current results of an ongoing research about a new data standards development concept. The concept is called Instant Standard referring to the pressure that is generated by shrinking the length of the standardization process. Based on this concept it is estimated that the

  2. Normalization method for metabolomics data using optimal selection of multiple internal standards

    Directory of Open Access Journals (Sweden)

    Yetukuri Laxman

    2007-03-01

    Full Text Available Abstract Background Success of metabolomics as the phenotyping platform largely depends on its ability to detect various sources of biological variability. Removal of platform-specific sources of variability such as systematic error is therefore one of the foremost priorities in data preprocessing. However, chemical diversity of molecular species included in typical metabolic profiling experiments leads to different responses to variations in experimental conditions, making normalization a very demanding task. Results With the aim to remove unwanted systematic variation, we present an approach that utilizes variability information from multiple internal standard compounds to find optimal normalization factor for each individual molecular species detected by metabolomics approach (NOMIS. We demonstrate the method on mouse liver lipidomic profiles using Ultra Performance Liquid Chromatography coupled to high resolution mass spectrometry, and compare its performance to two commonly utilized normalization methods: normalization by l2 norm and by retention time region specific standard compound profiles. The NOMIS method proved superior in its ability to reduce the effect of systematic error across the full spectrum of metabolite peaks. We also demonstrate that the method can be used to select best combinations of standard compounds for normalization. Conclusion Depending on experiment design and biological matrix, the NOMIS method is applicable either as a one-step normalization method or as a two-step method where the normalization parameters, influenced by variabilities of internal standard compounds and their correlation to metabolites, are first calculated from a study conducted in repeatability conditions. The method can also be used in analytical development of metabolomics methods by helping to select best combinations of standard compounds for a particular biological matrix and analytical platform.

  3. The use of high accuracy NAA for the certification of NIST Standard Reference Materials

    International Nuclear Information System (INIS)

    Becker, D.A.; Greenberg, R.R.; Stone, S.

    1991-01-01

    Neutron activation analysis (NAA) is only one of many analytical techniques used at the National Institute of Standards and Technology (NIST) for the certification of NIST Standard Reference Materials (SRMs). We compete daily against all of the other available analytical techniques in terms of accuracy, precision, and the cost required to obtain that requisite accuracy and precision. Over the years, the authors have found that NAA can and does compete favorably with these other techniques because of its' unique capabilities for redundancy and quality assurance. Good examples are the two new NIST leaf SRMs, Apple Leaves (SRM 1515) and Peach Leaves (SRM 1547). INAA was used to measure the homogeneity of 12 elements in 15 samples of each material at the 100 mg sample size. In addition, instrumental and radiochemical NAA combined for 27 elemental determinations, out of a total of 54 elemental determinations made on each material with all NIST techniques combined. This paper describes the NIST NAA procedures used in these analyses, the quality assurance techniques employed, and the analytical results for the 24 elements determined by NAA in these new botanical SRMs. The NAA results are also compared to the final certified values for these SRMs

  4. Fathead minnows (Pimephales promelas) and goldfish (Carassius auratus) as standard fish in bioassays and their reaction to potential reference toxicants

    Energy Technology Data Exchange (ETDEWEB)

    Adelman, I.R.; Smith, L.L. Jr.

    1976-02-01

    Fathead minnows (Pimephales promelas) and goldfish (Carassius auratus) were compared for their suitability as standard bioassay fish. Both species showed the same variability of bioassay results when tested with four toxicants. Fathead minnows are recommended on the basis of their small size and on their capability for use in complete life cycle tests. On the basis of minimum variability of bioassay results, sodium chloride was superior for use as a reference toxicant. Both sodium chloride and pentachlorophenol seemed capable of detecting abnormal fish. On the basis of seven listed criteria either sodium chloride or pentachlorophenol would be acceptable as a reference toxicant.

  5. Development of a Whole Body Atlas for Radiation Therapy Planning and Treatment Optimization

    International Nuclear Information System (INIS)

    Qatarneh, Sharif

    2006-01-01

    The main objective of radiation therapy is to obtain the highest possible probability of tumor cure while minimizing adverse reactions in healthy tissues. A crucial step in the treatment process is to determine the location and extent of the primary tumor and its loco regional lymphatic spread in relation to adjacent radiosensitive anatomical structures and organs at risk. These volumes must also be accurately delineated with respect to external anatomic reference points, preferably on surrounding bony structures. At the same time, it is essential to have the best possible physical and radiobiological knowledge about the radiation responsiveness of the target tissues and organs at risk in order to achieve a more accurate optimization of the treatment outcome. A computerized whole body Atlas has therefore been developed to serve as a dynamic database, with systematically integrated knowledge, comprising all necessary physical and radiobiological information about common target volumes and normal tissues. The Atlas also contains a database of segmented organs and a lymph node topography, which was based on the Visible Human dataset, to form standard reference geometry of organ systems. The reference knowledge base and the standard organ dataset can be utilized for Atlas-based image processing and analysis in radiation therapy planning and for biological optimization of the treatment outcome. Atlas-based segmentation procedures were utilized to transform the reference organ dataset of the Atlas into the geometry of individual patients. The anatomic organs and target volumes of the database can be converted by elastic transformation into those of the individual patient for final treatment planning. Furthermore, a database of reference treatment plans was started by implementing state-of-the-art biologically based radiation therapy planning techniques such as conformal, intensity modulated, and radio biologically optimized treatment planning. The computerized Atlas can

  6. Reduction of fatigue loads on jacket substructure through blade design optimization for multimegawatt wind turbines at 50 m water depths

    DEFF Research Database (Denmark)

    NJOMO WANDJI, Wilfried; Pavese, Christian; Natarajan, Anand

    2016-01-01

    This paper addresses the reduction of the fore-aft damage equivalent moment at the tower base for multi-megawatt offshore wind turbines mounted on jacket type substructures at 50 m water depths. The study investigates blade design optimization of a reference 10 MW wind turbine under standard wind...... conditions of onshore sites. The blade geometry and structure is optimized to yield a design that minimizes tower base fatigue loads without significant loss of power production compared to that of the reference setup. The resulting blade design is then mounted on a turbine supported by a jacket and placed...

  7. New birth weight reference standards customised to birth order and sex of babies from South India

    Directory of Open Access Journals (Sweden)

    Kumar Velusamy Saravana

    2013-02-01

    Full Text Available Abstract Background The foetal growth standards for Indian children which are available today suffer due to methodological problems. These are, for example, not adhering to the WHO recommendation to base gestational age on the number of completed weeks and secondly, not excluding mothers with risk factors. This study has addressed both the above issues and in addition provides birthweight reference ranges with regard to sex of the baby and maternal parity. Methods Data from the labour room register from 1996 to 2010 was obtained. A rotational sampling scheme was used i.e. the 12 months of the year were divided into 4 quadrants. All deliveries in January were considered to represent the first quadrant. Similarly all deliveries in April, July and October were considered to represent 2nd, 3rd and 4th quadrants. In each successive year different months were included in each quadrant. Only those mothers aged 20–39 years and delivered between 24 to 42 weeks gestational age were considered. Those mothers with obstetric risk factors were excluded. The reference standards were fitted using the Generalized Additive Models for Location Scale and Shape (GAMLSS method for Box – Cox t distribution with cubic spline smoothing. Results There were 41,055 deliveries considered. When women with risk factors were excluded 19,501 deliveries could be included in the final analysis. The male babies of term firstborn were found to be 45 g heavier than female babies. The mean birthweights were 2934 g and 2889.5 g respectively. Similarly, among the preterm babies, the first born male babies weighed 152 g more than the female babies. The mean birthweights were 1996 g and 1844 g respectively. In the case of later born babies, the term male babies weighed 116grams more than the females. The mean birth weights were 3085 grams and 2969 grams respectively. When considering later born preterm babies, the males outweighed the female babies by 111 grams. The

  8. Validity and Reliability of a Glucometer Against Industry Reference Standards.

    Science.gov (United States)

    Salacinski, Amanda J; Alford, Micah; Drevets, Kathryn; Hart, Sarah; Hunt, Brian E

    2014-01-01

    As an appealing alternative to reference glucose analyzers, portable glucometers are recommended for self-monitoring at home, in the field, and in research settings. The purpose was to characterize the accuracy and precision, and bias of glucometers in biomedical research. Fifteen young (20-36 years; mean = 24.5), moderately to highly active men (n = 10) and women (n = 5), defined by exercising 2 to 3 times a week for the past 6 months, were given an oral glucose tolerance test (OGTT) after an overnight fast. Participants ingested 50, 75, or 150 grams of glucose over a 5-minute period. The glucometer was compared to a reference instrument. The glucometer had 39% of values within 15% of measurements made using the reference instrument ranging from 45.05 to 169.37 mg/dl. There was both a proportional (-0.45 to -0.39) and small fixed (5.06 and 0.90 mg/dl) bias. Results of the present study suggest that the glucometer provided poor validity and reliability results compared to the results provided by the reference laboratory analyzer. The portable glucometers should be used for patient management, but not for diagnosis, treatment, or research purposes. © 2014 Diabetes Technology Society.

  9. DAKOTA, a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis:version 4.0 reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Joshua D. (Sandai National Labs, Livermore, CA); Eldred, Michael Scott; Martinez-Canales, Monica L. (Sandai National Labs, Livermore, CA); Watson, Jean-Paul; Kolda, Tamara Gibson (Sandai National Labs, Livermore, CA); Adams, Brian M.; Swiler, Laura Painton; Williams, Pamela J. (Sandai National Labs, Livermore, CA); Hough, Patricia Diane (Sandai National Labs, Livermore, CA); Gay, David M.; Dunlavy, Daniel M.; Eddy, John P.; Hart, William Eugene; Guinta, Anthony A.; Brown, Shannon L.

    2006-10-01

    The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic finite element methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a reference manual for the commands specification for the DAKOTA software, providing input overviews, option descriptions, and example specifications.

  10. Standard and reference materials for environmental science. Part 1. Technical memo

    Energy Technology Data Exchange (ETDEWEB)

    Cantillo, A.Y.

    1995-11-01

    This is the fourth edition of the catalog of reference materials suited for use in environmental science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists more than 1200 reference materials from 28 producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds.

  11. Standard and reference materials for environmental science. Part 2. Technical memo

    Energy Technology Data Exchange (ETDEWEB)

    Cantillo, A.Y.

    1995-11-01

    This is the fourth edition of the catalog of reference materials suited for use in environmental science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists more than 1200 reference materials from 28 producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds.

  12. Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) with Standard Reference Line for the Analysis of Stainless Steel.

    Science.gov (United States)

    Fu, Hongbo; Dong, Fengzhong; Wang, Huadong; Jia, Junwei; Ni, Zhibo

    2017-08-01

    In this work, calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is used to analyze a certified stainless steel sample. Due to self-absorption of the spectral lines from the major element Fe and the sparse lines of trace elements, it is usually not easy to construct the Boltzmann plots of all species. A standard reference line method is proposed here to solve this difficulty under the assumption of local thermodynamic equilibrium so that the same temperature value for all elements present into the plasma can be considered. Based on the concentration and rich spectral lines of Fe, the Stark broadening of Fe(I) 381.584 nm and Saha-Boltzmann plots of this element are used to calculate the electron density and the plasma temperature, respectively. In order to determine the plasma temperature accurately, which is seriously affected by self-absorption, a pre-selection procedure for eliminating those spectral lines with strong self-absorption is employed. Then, one spectral line of each element is selected to calculate its corresponding concentration. The results from the standard reference lines with and without self-absorption of Fe are compared. This method allows us to measure trace element content and effectively avoid the adverse effects due to self-absorption.

  13. Optimization of patient protection using rare earth screen in conventional imaging procedure

    International Nuclear Information System (INIS)

    Inkoom, S.; Schandorf, C.; Fletcher, J.J.

    2008-01-01

    The purpose of this study was to optimize patient protection using rare earth screen of speed 400 in place of conventional screen-film of speed 200. The entrance surface dose (ESD) for the two screen-film systems was determined for patients undergoing simple radiographic examinations (chest, lumbar spine and pelvis series). The determination of the ESD included backscatter factors. The ESD was the optimizing parameter and its trade off with the image quality assessment, which was surveyed based on the information obtained through standardized questionnaire. The estimated ESDs were compared with reference levels set by the Community of European Commission (CEC) for a standard adult patient. For chest PA, ESD estimates were lower than the CEC reference levels whilst that of lumbar spine AP and LAT and pelvis AP were high. Upon the adoption of rare earth screen of speed 400, a dose reduction of 33% for chest, 17% for lumbar spine and 28% for pelvis examinations was achieved. From the observations made from this study, some corrective actions such as equipment quality control of parameters that affect patient dose and image quality like kVp accuracy and consistency, mAs accuracy and consistency, optimal film processing conditions, regular film reject analysis to detect and minimize the root causes and contributory factors to poor image quality and periodic training of staff on dose reduction techniques must be undertaken. Regular assessment of patient dose and image quality, equipment quality control, adoption of faster rare earth screens and optimum radiographic technique are therefore recommended in order to achieve optimization goals. (author)

  14. Reference satellite selection method for GNSS high-precision relative positioning

    Directory of Open Access Journals (Sweden)

    Xiao Gao

    2017-03-01

    Full Text Available Selecting the optimal reference satellite is an important component of high-precision relative positioning because the reference satellite directly influences the strength of the normal equation. The reference satellite selection methods based on elevation and positional dilution of precision (PDOP value were compared. Results show that all the above methods cannot select the optimal reference satellite. We introduce condition number of the design matrix in the reference satellite selection method to improve structure of the normal equation, because condition number can indicate the ill condition of the normal equation. The experimental results show that the new method can improve positioning accuracy and reliability in precise relative positioning.

  15. Reference samples for the earth sciences

    Science.gov (United States)

    Flanagan, F.J.

    1974-01-01

    A revised list of reference samples of interest to geoscientists has been extended to include samples for the agronomist, the archaeologist and the environmentalist. In addition to the source from which standard samples may be obtained, references or pertinent notes for some samples are included. The number of rock reference samples is now almost adequate, and the variety of ore samples will soon be sufficient. There are very few samples for microprobe work. Oil shales will become more important because of the outlook for world petroleum resources. The dryland equivalent of a submarine basalt might be useful in studies of sea-floor spreading and of the geochemistry of basalts. The Na- and K-feldspars of BCS (British Chemical Standards-Bureau of Analysed Samples), NBS (National Bureau of Standards), and ANRT (Association Kationale de la Recherche Technique) could serve as trace-element standards if such data were available. Similarly, the present NBS flint and plastic clays, as well as their predecessors, might be useful for archaeological pottery studies. The International Decade for Ocean Exploration may stimulate the preparation of ocean-water standards for trace elements or pollutants and a standard for manganese nodules. ?? 1974.

  16. Determination of caffeine, theobromine, and theophylline in standard reference material 2384, baking chocolate, using reversed-phase liquid chromatography.

    Science.gov (United States)

    Thomas, Jeanice Brown; Yen, James H; Schantz, Michele M; Porter, Barbara J; Sharpless, Katherine E

    2004-06-02

    A rapid and selective isocratic reversed-phase liquid chromatographic method has been developed at the National Institute of Standards and Technology to simultaneously measure caffeine, theobromine, and theophylline in a food-matrix standard reference material (SRM) 2384, Baking Chocolate. The method uses isocratic elution with a mobile phase composition (volume fractions) of 10% acetronitrile/90% water (pH adjusted to 2.5 using acetic acid) at a flow rate of 1.5 mL/min with ultraviolet absorbance detection (274 nm). Total elution time for these analytes is less than 15 min. Concentration levels of caffeine, theobromine, and theophylline were measured in single 1-g samples taken from each of eight bars of chocolate over an eight-day period. Samples were defatted with hexane, and beta-hydroxyethyltheophylline was added as the internal standard. The repeatability for the caffeine, theobromine, and theophylline measurements was 5.1, 2.3, and 1.9%, respectively. The limit of quantitation for all analytes was theobromine, and theophylline in SRM 2384.

  17. NEURO-SYSTEM OF AIMING AND STABILIZING WITH A REGULATOR ON THE BASIS OF STANDARD MODEL MODEL REFERENCE CONTROLLER

    Directory of Open Access Journals (Sweden)

    B.I. Kuznetsov

    2015-08-01

    Full Text Available The aim of this work is the synthesis of neural network aiming and stabilization system for the special equipment of moving objects with neuro-controller on the basis of standard model and performance comparison of the neural network system with the neural network predictive control. Build a block diagram of the neural network aiming and stabilization system, based on the subject control principle with PD-regulator in the position loop and with neuro-controller on the basis of standard model in the in the velocity loop. The neuro-controller on the basis of standard model Model Reference Controller is synthesized in the MATLAB Neural Network Toolbox and system simulation is performed. The studies show that the transient state variables of the system are oscillatory. Therefore, the neuro-controller with the prediction NN Predictive Controller should be used for aiming and stabilizing system to provide high dynamic characteristics achieved at the cost of higher complexity and computational cost.

  18. Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

    Science.gov (United States)

    Novelli, P. C.; Collins, J. E., Jr.; Myers, R. C.; Sachse, G. W.; Scheel, H. E.

    1994-01-01

    The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. The calibration of six standards (CO concentrations between approximately 50 and approximately 210 ppb) by CMDL and the Fraunhofer-Institut agreed to within +/- 2% for four

  19. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.

    Science.gov (United States)

    Malusek, A; Helmrot, E; Sandborg, M; Grindborg, J-E; Carlsson, G Alm

    2014-12-07

    The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least ± 7% (k = 2). Industry standards defined by the International Electrotechnical Commission (IEC) specify that the uncertainty of KAP meter measurements should be less than ± 25% (k = 2). Medical physicists willing to comply with the IAEA's recommendation need to apply correction factors to KAP values reported by x-ray units. The aim of this work is to present and evaluate a calibration method for built-in KAP meters on clinical x-ray units. The method is based on (i) a tandem calibration method, which uses a reference KAP meter calibrated to measure the incident radiation, (ii) measurements using an energy-independent ionization chamber to correct for the energy dependence of the reference KAP meter, and (iii) Monte Carlo simulations of the beam quality correction factors that correct for differences between beam qualities at a standard laboratory and the clinic. The method was applied to the KAP meter in a Siemens Aristos FX plus unit. It was found that values reported by the built-in KAP meter differed from the more accurate values measured by the reference KAP meter by more than 25% for high tube voltages (more than 140 kV) and heavily filtered beams (0.3 mm Cu). Associated uncertainties were too high to claim that the IEC's limit of 25% was exceeded. Nevertheless the differences were high enough to justify the need for a more accurate calibration of built-in KAP meters.

  20. 1 CFR 21.21 - General requirements: References.

    Science.gov (United States)

    2010-01-01

    ... 1 General Provisions 1 2010-01-01 2010-01-01 false General requirements: References. 21.21 Section... to test methods or consensus standards produced by a Federal agency that have replaced or preempted private or voluntary test methods or consensus standards in a subject matter area. (5) The reference is to...

  1. Employment references: defamation law in the clinical laboratory.

    Science.gov (United States)

    Parks, D G

    1993-01-01

    The law of defamation and the risks involved in issuing employment references are discussed. A hypothetical scenario is used to illustrate the legal standards governing the tort of defamation and to apply those standards to employment references. Practical suggestions for a "controlled reference" policy are provided, with the objective of allowing for responsible exchange of employment information and avoiding a defamation lawsuit.

  2. Quantitative determination and validation of octreotide acetate using 1 H-NMR spectroscopy with internal standard method.

    Science.gov (United States)

    Yu, Chen; Zhang, Qian; Xu, Peng-Yao; Bai, Yin; Shen, Wen-Bin; Di, Bin; Su, Meng-Xiang

    2018-01-01

    Quantitative nuclear magnetic resonance (qNMR) is a well-established technique in quantitative analysis. We presented a validated 1 H-qNMR method for assay of octreotide acetate, a kind of cyclic octopeptide. Deuterium oxide was used to remove the undesired exchangeable peaks, which was referred to as proton exchange, in order to make the quantitative signals isolated in the crowded spectrum of the peptide and ensure precise quantitative analysis. Gemcitabine hydrochloride was chosen as the suitable internal standard. Experimental conditions, including relaxation delay time, the numbers of scans, and pulse angle, were optimized first. Then method validation was carried out in terms of selectivity, stability, linearity, precision, and robustness. The assay result was compared with that by means of high performance liquid chromatography, which is provided by Chinese Pharmacopoeia. The statistical F test, Student's t test, and nonparametric test at 95% confidence level indicate that there was no significant difference between these two methods. qNMR is a simple and accurate quantitative tool with no need for specific corresponding reference standards. It has the potential of the quantitative analysis of other peptide drugs and standardization of the corresponding reference standards. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

    Energy Technology Data Exchange (ETDEWEB)

    Novelli, P.C.; Collins, J.E. Jr.; Myers, R.C.; Sachse, G.W.; Scheel, H.E. [Univ. of Colordo, Boulder, CO (United States)]|[Science and Technology Corporation, Hampton, VA (United States)]|[NOAA, Boulder, CO (United States)]|[NASA, Langley Research Center, Hampton, VA (United States)]|[Fraunhofer-Inst. fuer Atmospharishce Umweltforschung (Germany)

    1994-06-01

    The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. (Abstract Truncated)

  4. High-resolution global grids of revised Priestley-Taylor and Hargreaves-Samani coefficients for assessing ASCE-standardized reference crop evapotranspiration and solar radiation

    Science.gov (United States)

    Aschonitis, Vassilis G.; Papamichail, Dimitris; Demertzi, Kleoniki; Colombani, Nicolo; Mastrocicco, Micol; Ghirardini, Andrea; Castaldelli, Giuseppe; Fano, Elisa-Anna

    2017-08-01

    The objective of the study is to provide global grids (0.5°) of revised annual coefficients for the Priestley-Taylor (P-T) and Hargreaves-Samani (H-S) evapotranspiration methods after calibration based on the ASCE (American Society of Civil Engineers)-standardized Penman-Monteith method (the ASCE method includes two reference crops: short-clipped grass and tall alfalfa). The analysis also includes the development of a global grid of revised annual coefficients for solar radiation (Rs) estimations using the respective Rs formula of H-S. The analysis was based on global gridded climatic data of the period 1950-2000. The method for deriving annual coefficients of the P-T and H-S methods was based on partial weighted averages (PWAs) of their mean monthly values. This method estimates the annual values considering the amplitude of the parameter under investigation (ETo and Rs) giving more weight to the monthly coefficients of the months with higher ETo values (or Rs values for the case of the H-S radiation formula). The method also eliminates the effect of unreasonably high or low monthly coefficients that may occur during periods where ETo and Rs fall below a specific threshold. The new coefficients were validated based on data from 140 stations located in various climatic zones of the USA and Australia with expanded observations up to 2016. The validation procedure for ETo estimations of the short reference crop showed that the P-T and H-S methods with the new revised coefficients outperformed the standard methods reducing the estimated root mean square error (RMSE) in ETo values by 40 and 25 %, respectively. The estimations of Rs using the H-S formula with revised coefficients reduced the RMSE by 28 % in comparison to the standard H-S formula. Finally, a raster database was built consisting of (a) global maps for the mean monthly ETo values estimated by ASCE-standardized method for both reference crops, (b) global maps for the revised annual coefficients of the P

  5. [Classification of Colombian children with malnutrition according to NCHS reference or WHO standard].

    Science.gov (United States)

    Velásquez, Claudia; Bermúdez, Juliana; Echeverri, Claudia; Estrada, Alejandro

    2011-12-01

    A descriptive study was conducted to evaluate the concordance of National Center for Health Statistics reference (NCHS) used to classify undernourished children from Colombia with the WHO Child Growth Standards. We used data from children aged 6 to 59 months with acute malnutrition (Z Infantil" nutrition program in Colombia. Indicators height-for-age, weight for-height were analyzed when they were admitted to the hospital and weight for-height leaving the hospital. A statistical method used to compare means was T-student. Correlation coefficient intraclass (CCI) and Kappa index evaluated the concordance between NCHS and OMS; McNemar method evaluated the changes on the nutritional classification for children according to growth devices used. Of the total number of children classified as normal by NCHS, 10.4% were classified as stunted by WHO. 64% of the children admitted to the hospital presented acute malnutrition according to NCHS, of these 44,8% presented severe emaciation according to OMS, indeed severe emaciation increased of 36,0% to 63,3% using OMS. 5% of children leaving the hospital could need to stay more days if they had been evaluated with OMS. Growth devices shown high concordance in height-for-age (CCI = 0,988; k= 0,866) and weight for-height (CCI = 0,901; k = 0,578). Concluded that OMS growth standards classified more malnourished children and more severe states, in addition more malnourished children could be hospitalized and they could stay more days.

  6. Standardization of glycohemoglobin results and reference values in whole blood studied in 103 laboratories using 20 methods.

    Science.gov (United States)

    Weykamp, C W; Penders, T J; Miedema, K; Muskiet, F A; van der Slik, W

    1995-01-01

    We investigated the effect of calibration with lyophilized calibrators on whole-blood glycohemoglobin (glyHb) results. One hundred three laboratories, using 20 different methods, determined glyHb in two lyophilized calibrators and two whole-blood samples. For whole-blood samples with low (5%) and high (9%) glyHb percentages, respectively, calibration decreased overall interlaboratory variation (CV) from 16% to 9% and from 11% to 6% and decreased intermethod variation from 14% to 6% and from 12% to 5%. Forty-seven laboratories, using 14 different methods, determined mean glyHb percentages in self-selected groups of 10 nondiabetic volunteers each. With calibration their overall mean (2SD) was 5.0% (0.5%), very close to the 5.0% (0.3%) derived from the reference method used in the Diabetes Control and Complications Trial. In both experiments the Abbott IMx and Vision showed deviating results. We conclude that, irrespective of the analytical method used, calibration enables standardization of glyHb results, reference values, and interpretation criteria.

  7. Discrete Optimization in Chemical Space Reference Manual

    Science.gov (United States)

    2012-10-01

    includes instructions on setting up constrained optimizations of substitutional frameworks and the full application programming interface ( API ) necessary...space size • bool space size computed • ulong bits • bool bits computed • string Nam 4.26.1 Detailed Description This class provides the API that...1, 0) 1102 (O, 0, 1.4, -3, 120, -2, 180) 1103 (C, 1, 1.5, 0, 120, -3, -30(150)) 1104 (H, 2, 1.1, 1, 109.47, 0,180) 1105 (H, 2, 1.1, 1, 109.47, 3, 120

  8. Development of C-reactive protein certified reference material NMIJ CRM 6201-b: optimization of a hydrolysis process to improve the accuracy of amino acid analysis.

    Science.gov (United States)

    Kato, Megumi; Kinumi, Tomoya; Yoshioka, Mariko; Goto, Mari; Fujii, Shin-Ichiro; Takatsu, Akiko

    2015-04-01

    To standardize C-reactive protein (CRP) assays, the National Metrology Institute of Japan (NMIJ) has developed a C-reactive protein solution certified reference material, CRM 6201-b, which is intended for use as a primary reference material to enable the SI-traceable measurement of CRP. This study describes the development process of CRM 6201-b. As a candidate material of the CRM, recombinant human CRP solution was selected because of its higher purity and homogeneity than the purified material from human serum. Gel filtration chromatography was used to examine the homogeneity and stability of the present CRM. The total protein concentration of CRP in the present CRM was determined by amino acid analysis coupled to isotope-dilution mass spectrometry (IDMS-AAA). To improve the accuracy of IDMS-AAA, we optimized the hydrolysis process by examining the effect of parameters such as the volume of protein samples taken for hydrolysis, the procedure of sample preparation prior to the hydrolysis, hydrolysis temperature, and hydrolysis time. Under optimized conditions, we conducted two independent approaches in which the following independent hydrolysis and liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) were combined: one was vapor-phase acid hydrolysis (130 °C, 24 h) and hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) method, and the other was microwave-assisted liquid-phase acid hydrolysis (150 °C, 3 h) and pre-column derivatization liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. The quantitative values of the two different amino acid analyses were in agreement within their uncertainties. The certified value was the weighted mean of the results of the two methods. Uncertainties from the value-assignment method, between-method variance, homogeneity, long-term stability, and short-term stability were taken into account in evaluating the uncertainty for a certified value. The certified value and the

  9. New birth weight reference standards customised to birth order and sex of babies from South India.

    Science.gov (United States)

    Kumar, Velusamy Saravana; Jeyaseelan, Lakshmanan; Sebastian, Tunny; Regi, Annie; Mathew, Jiji; Jose, Ruby

    2013-02-14

    The foetal growth standards for Indian children which are available today suffer due to methodological problems. These are, for example, not adhering to the WHO recommendation to base gestational age on the number of completed weeks and secondly, not excluding mothers with risk factors. This study has addressed both the above issues and in addition provides birthweight reference ranges with regard to sex of the baby and maternal parity. Data from the labour room register from 1996 to 2010 was obtained. A rotational sampling scheme was used i.e. the 12 months of the year were divided into 4 quadrants. All deliveries in January were considered to represent the first quadrant. Similarly all deliveries in April, July and October were considered to represent 2nd, 3rd and 4th quadrants. In each successive year different months were included in each quadrant. Only those mothers aged 20-39 years and delivered between 24 to 42 weeks gestational age were considered. Those mothers with obstetric risk factors were excluded. The reference standards were fitted using the Generalized Additive Models for Location Scale and Shape (GAMLSS) method for Box-Cox t distribution with cubic spline smoothing. There were 41,055 deliveries considered. When women with risk factors were excluded 19,501 deliveries could be included in the final analysis. The male babies of term firstborn were found to be 45 g heavier than female babies. The mean birthweights were 2934 g and 2889.5 g respectively. Similarly, among the preterm babies, the first born male babies weighed 152 g more than the female babies. The mean birthweights were 1996 g and 1844 g respectively.In the case of later born babies, the term male babies weighed 116 grams more than the females. The mean birth weights were 3085 grams and 2969 grams respectively. When considering later born preterm babies, the males outweighed the female babies by 111 grams. The mean birthweights were 2089 grams and 1978 grams

  10. Disposable Miniaturized Screen‐Printed pH and Reference Electrodes for Potentiometric Systems

    DEFF Research Database (Denmark)

    Musa, Arnaud Emmanuel; del Campo, Francisco Javier; Abramova, Natalia

    2011-01-01

    This work describes the development of a miniaturized potentiometric system comprising a miniaturized quasi‐reference electrode (QRE) coupled to a solid‐state ion‐selective electrode (ISE) for the monitoring of pH. We describe the optimization of materials and fabrication processes including screen‐printing...... electrode) that can be used continuously for a period of not less than 7 days in aqueous solutions. Curing the Ag/AgCl pastes during 20 minutes at 120 °C after printing allowed the QREs to display excellent potential stability, as demonstrated by an open‐circuit‐potential standard deviation of ±1.2 mV over...

  11. Using the Wisconsin-Ohio Reference Evaluation Program (WOREP) to Improve Training and Reference Services

    Science.gov (United States)

    Novotny, Eric; Rimland, Emily

    2007-01-01

    This article discusses a service quality study conducted in the Pennsylvania State University Libraries. The Wisconsin-Ohio Reference Evaluation Program survey was selected as a valid, standardized instrument. We present our results, highlighting the impact on reference training. A second survey a year later demonstrated that focusing on…

  12. Standard and reference materials for marine science. Third edition. Technical memo

    International Nuclear Information System (INIS)

    Cantillo, A.Y.

    1992-08-01

    The third edition of the catalog of reference materials suited for use in marine science, originally compiled in 1986 for NOAA, IOC, and UNEP. The catalog lists close to 2,000 reference materials from sixteen producers and contains information about their proper use, sources, availability, and analyte concentrations. Indices are included for elements, isotopes, and organic compounds, as are cross references to CAS registry numbers, alternate names, and chemical structures of selected organic compounds. The catalog is being published independently by both NOAA and IOC/UNEP and is available from NOAA/NOS/ORCA in electronic form

  13. Handbook of optimization in telecommunications

    CERN Document Server

    Pardalos, Panos M

    2008-01-01

    Covers the field of optimization in telecommunications, and the optimization developments that are frequently applied to telecommunications. This book aims to provide a reference tool for scientists and engineers in telecommunications who depend upon optimization.

  14. Development of a certified reference material for composition of high-purity copper as a transfer standard within GET 176-2013

    Directory of Open Access Journals (Sweden)

    Veniamin M. Zyskin

    2017-01-01

    Full Text Available Introduction. The paper gives information on the development of a certified reference material (CRM for composition of high-purity copper (Cu CRM UNIIM. The CRM is included as the transfer standard into the State primary standard of the mass (molar fraction and mass (molar concentration of the component in liquid and solid substances and materials based on coulometry GET 176-2013.Materials and methods. The CRM represents pieces of oxygen-free copper wire rod, brand KMB, produced according to GOST R 53803-2010, weighing from 0.5 to 1g. The CRM is packed in plastic vials with the capacity of 30 or 50 cm3. The certified characteristic of the CRM is copper mass fraction in copper wire rod, expressed in percentages. The certified value for copper mass fraction was established by the primary method of controlled-potential coulometry using the State primary standard GET 176-2013.Results. The permitted interval of the certified value for copper mass fraction in the CRM is from 99,950 % to 100,000 %. The relative expanded uncertainty (k=2 of the certified value for copper mass fraction does not exceed 0,030 %; the relative standard uncertainty due to inhomogeneity does not exceed 0.010 %; the relative standard uncertainty due to instability does not exceed 0.010 %. The shelf life of the developed CRM is 10 years provided that standard storage conditions are ensured.Discussion and conclusions. The developed CRM is included into the State register of type approved RMs under the number GSO 10800-2016. The CRM of high-purity copper (Cu CRM UNIIM as a transfer standard is intended for reproduction, storage and transfer of the copper mass fraction unit to other reference materials and chemical reagents by the method of comparison using a comparator and by conducting direct measurements. This CRM may also be used:– for verification of measuring instruments (MIs according to the state verification schedule described in GOST R 8.735.0-2014,– for calibration

  15. WHO Standard Acupuncture Point Locations

    Directory of Open Access Journals (Sweden)

    Sabina Lim

    2010-01-01

    Full Text Available ‘WHO Standard Acupuncture Point Locations in the Western Pacific Region (WHO Standard was released in 2008. Initially, there were 92/361 controversial acupuncture points (acupoints. Through seven informal consultations and four task force team meetings, 86 points were agreed upon among the 92 controversial acupoints, leaving 6 remaining controversial acupoints, demanding active research in the future. This will enhance the reproducibility and validity of acupuncture studies. It will also lead to a better understanding of acupuncture mechanisms in order to optimize its clinical efficacy for a range of diseases and syndromes. This book has two parts: General Guidelines for Acupuncture Point Locations and WHO Standard Acupuncture Point Locations. First of all, familiarity with the General Guidelines for Acupuncture Point Locations in this book can help the reader to understand and use the contents of this book in depth. I would like to thank all of the participating experts and scholars for this great work, who have overcome the limits of previous acupuncture references. I also appreciate the dedicated effort and harmonious leadership of Dr Choi Seung-hoon, former Regional Adviser in Traditional Medicine of Western Pacific Office, WHO.

  16. Reference News Release: U.S. Files Complaint, Announces Settlement to Address Alleged Renewable Fuel Standard Violations by NGL Crude Logistics and Western Dubuque Biodiesel

    Science.gov (United States)

    Reference news release on the complaint against NGL Crude Logistics, LLC and Western Dubuque Biodiesel, LLC and a settlement with Western Dubuque to address alleged violations of the Renewable Fuel Standard.

  17. Consequences of new reference climate years according to the Dutch standard NEN 5060; Gevolgen nieuwe referentieklimaatjaren volgens NEN 5060

    Energy Technology Data Exchange (ETDEWEB)

    Hooft, E.N. ' t [Grontmij, Amersfoort (Netherlands)

    2009-02-15

    Because of the climate changes the reference year 1964-1965 is a topic of discussion as on appropriate climate file for the design of climate installations. Therefor, in the Netherlands, new climate reference years are developed for temperature and energy calculations, outlined in the Dutch standard NEN 5060 (Hygrothermal properties of buildings. Reference climate data). This article shows for a nursing home the consequences on the design, energy consumption and energy costs of the climate installation. [Dutch] Vanwege de klimaatveranderingen, die een duidelijke trend naar warmere jaren laat zien, staat het referentiejaar 1964-1965 ter discussie als geschikt klimaatbestand voor bet ontwerp van klimaatinstallaties. Om die reden zijn voor Nederland nieuwe referentieklimaatjaren ontwikkeld voor temperatuur- en energieberekeningen, die zijn opgenomen in NEN 5060 (Hygro-thermische eigenschappen van gebouwen. Referentieklimaatgegevens), die als definitieve versie is verschenen. Dit artikel laat aan de hand van een rekenstudie aan een referentiegebouw in de gezondheidszorg (verpleeghuis) zien wat de consequenties zijn van de nieuw ontwikkelde referentieklimaatjaren op bet ontwerp, het energiegebruik en de energiekosten van de klimaatinstallatie.

  18. Certification of a reference material for determination of total cyanide in soil to support implementation of the International Standard ISO 11262:2011.

    Science.gov (United States)

    Scharf, Holger; Bremser, Wolfram

    2015-04-01

    Cyanides are among the most important inorganic pollutants to be tested and monitored in environmental compartments. They can be distinguished and determined as free cyanide, weak acid dissociable cyanide or as total cyanide. However, in any case obtained, measurement results are operationally defined referring to the applied analytical method. In 2011, the International Standard ISO 11262 has been published which specifies a normative analytical method for the determination of total cyanide in soil. The objective of the project described in this paper was to provide the first soil reference material (CRM) certified for its mass fraction of total cyanide on the basis of this standard. A total of 12 German laboratories with proven experience in the determination of cyanides in environmental samples participated in the certification study. Measurement results were evaluated in full compliance with the requirements of ISO Guide 35. Taking into account the results of the inter-laboratory comparison as well as the outcome of the homogeneity and stability studies, a certified mass fraction of total cyanide of 21.1 mg/kg and an expanded uncertainty (k = 2) of 1.3 mg/kg were assigned to the material. The reference material has been issued as CRM BAM-U114.

  19. An efficient auto TPT stitch guidance generation for optimized standard cell design

    Science.gov (United States)

    Samboju, Nagaraj C.; Choi, Soo-Han; Arikati, Srini; Cilingir, Erdem

    2015-03-01

    As the technology continues to shrink below 14nm, triple patterning lithography (TPT) is a worthwhile lithography methodology for printing dense layers such as Metal1. However, this increases the complexity of standard cell design, as it is very difficult to develop a TPT compliant layout without compromising on the area. Hence, this emphasizes the importance to have an accurate stitch generation methodology to meet the standard cell area requirement as defined by the technology shrink factor. In this paper, we present an efficient auto TPT stitch guidance generation technique for optimized standard cell design. The basic idea here is to first identify the conflicting polygons based on the Fix Guidance [1] solution developed by Synopsys. Fix Guidance is a reduced sub-graph containing minimum set of edges along with the connecting polygons; by eliminating these edges in a design 3-color conflicts can be resolved. Once the conflicting polygons are identified using this method, they are categorized into four types [2] - (Type 1 to 4). The categorization is based on number of interactions a polygon has with the coloring links and the triangle loops of fix guidance. For each type a certain criteria for keep-out region is defined, based on which the final stitch guidance locations are generated. This technique provides various possible stitch locations to the user and helps the user to select the best stitch location considering both design flexibility (max. pin access/small area) and process-preferences. Based on this technique, a standard cell library for place and route (P and R) can be developed with colorless data and a stitch marker defined by designer using our proposed method. After P and R, the full chip (block) would contain the colorless data and standard cell stitch markers only. These stitch markers are considered as "must be stitch" candidates. Hence during full chip decomposition it is not required to generate and select the stitch markers again for the

  20. Development and evaluation of weight and height reference ...

    African Journals Online (AJOL)

    While international reference standard exists, it has been suggested that locally generated norms would be more realistic and appropriate, especially in adults where great variations in stature among nations exist. This study was undertaken to develop a table of reference standard for weight and height for young adults in

  1. Direct calibration of GC/MS systems using SRM (Standard Reference Material) gas cylinders. Project report, January 1984-August 1985

    International Nuclear Information System (INIS)

    Byrd, G.D.; Richie, K.L.; Sniegoski, L.T.; White, E.

    1985-10-01

    A cryogenic trapping system has been developed for use in calibrating GC/MS systems for the analysis of volatile organic compounds. This system provides for direct Standard Reference Material (SRM) traceability on data generated on gaseous samples. The cryogenic trap is a coil of stainless steel tubing immersed in a cryogen to trap and preconcentrate organic species present in a gaseous sample. The trap also contains a heated injection port for the addition of isotopically labeled compounds for use in isotope dilution measurements. The first part of this research is concerned with the development of IDMS as an independent method for the quantification of analytes in gaseous samples to be used as standards. Results are presented for the determination of bromobenzene in nitrogen at nominal concentrations of 1 and 25 ppb. In the second part of the research, a calibration curve method was developed for using these standards in auditing the performance of GC/MS systems

  2. Quine's Double Standard: Undermining the Indispensability Argument via the Indeterminacy of Reference

    Directory of Open Access Journals (Sweden)

    Otávio Bueno

    2003-12-01

    Full Text Available Quine has famously put forward the indispensability argument to force belief in the existence of mathematical objects (such as classes due to their indispensability to our best theories of the world (Quine 1960. Quine has also advocated the indeterminacy of reference argument, according to which reference is dramatically indeterminate: given a language, there’s no unique reference relation for that language (see Quine 1969a. In this paper, I argue that these two arguments are in conflict with each other. Whereas the indispensability argument supports realism about mathematics, the indeterminacy of reference argument, when applied to mathematics, provides a powerful strategy in support of mathematical anti-realism. I conclude the paper by indicating why the indeterminacy of reference phenomenon should be preferred over the considerations regarding indispensability. In the end, even the Quinean shouldn’t be a realist (platonist about mathematics.

  3. Development of a standard reference material containing 22 chlorinated hydrocarbon gases at 1 μmol/mol in nitrogen.

    Science.gov (United States)

    Li, Ning; Du, Jian; Yang, Jing; Fan, Qiang; Tian, Wen

    2017-11-01

    A gas standard mixture containing 22 chlorinated hydrocarbons in high purity nitrogen was prepared using a two-step weighing method and a gasifying apparatus developed in-house. The concentration of each component was determined using a gas chromatograph with flame ionization detection (GC/FID). Linear regression analysis of every component was performed using the gas standard mixture with concentrations ranging from 1 to 10 μmol/mol, showing the complete gasification of volatile organic compound (VOCs) species in a selected cylinder. Repeatability was also examined to ensure the reliability of the preparation method. In addition, no significant difference was observed between domestic treated and imported treated cylinders, which were conducive to reduction of the cost of raw materials. Moreover, the results of stability testing at different pressures and long-term stability tests indicated that the gas standard at 1 μmol/mol level with relative expanded uncertainties of 5% was stable above 2 MPa for a minimum of 12 months. Finally, a quantity comparison was conducted between the gas standard and a commercial gas standard from Scott Specialty Gases (now Air Liquide America Specialty Gases). The excellent agreement of every species suggested the favorable accuracy of our gas standard. Therefore, this reference material can be applied to routine observation of VOCs and for other purposes.

  4. Effect of polytetrafluoroethylene (PTFE) phase transition at 19°C on the use of Spectralon as a reference standard for reflectance.

    Science.gov (United States)

    Ball, Christopher P; Levick, Andrew P; Woolliams, Emma R; Green, Paul D; Dury, Martin R; Winkler, Rainer; Deadman, Andrew J; Fox, Nigel P; King, Martin D

    2013-07-10

    Sintered polytetrafluoroethylene (PTFE) is highly reflective and is widely used as a reference standard in remote sensing, radiometry, and spectroscopy. The relative change in output flux from a PTFE integrating sphere over the room temperature phase transition at 19°C has been measured at a monochromatic wavelength of 633 nm as 1.82±0.21%. The change in output flux was attributed to a small change of 0.09±0.02% in the total hemispherical reflectance of PTFE, caused by a change in its material density as a result of the phase transition. For the majority of users, this small change measured in total hemispherical reflectance is unlikely to impact significantly the accuracy of PTFE flat panel reflectors used as reference standards. However, owing to the multiple reflections that occur inside an integrating sphere cavity, the effect is multiplied and remedial action should be applied, either via a mathematical correction or through temperature stabilization of the integrating sphere when high accuracy (PTFE-based integrating spheres at temperatures close to the phase transition at 19°C.

  5. CLASSIFICATION OF RESTRAINTS IN THE OPTIMIZATION PROBLEM OF A COLD-FORMED PROFILE

    Directory of Open Access Journals (Sweden)

    Agnieszka Łukowicz

    2015-11-01

    Full Text Available This work describes the restraints in the optimization problem. This is an important and complicated issue because it requires taking into account a vast range of information related to the design and production. In order to describe the relations of a specific optimization problem, it is essential to adopt appropriate criteria and to collect information on all kinds of restraints, i.e. boundary conditions. The following paper verifies the various restraints and defines three subsets: design assumptions, technological limitations and standard conditions. The provided classification was made with reference to the analysis of the construction applicability of the newly patented cold-formed profile.

  6. Optimization of Multiband White-Light Illuminants for Specified Color Temperatures

    Directory of Open Access Journals (Sweden)

    Snjezana Soltic

    2015-01-01

    Full Text Available This paper describes an effective approach for the optimization of multiband spectra to produce prospective white-light spectra having specific color temperatures. The optimization process employs a genetic algorithm known as differential evolution, which aims to minimize the color rendering differences between a prospective white-light spectrum and its corresponding reference illuminant. Color rendering is assessed by calculating the CIEDE2000 color difference (ΔE00 for 14 CIE test colors under the two sources. Optimized white-light spectra were matched to three CIE standard illuminants, that is, A (2856 K, D50 (5003 K, and D65 (6504 K. Optimal solutions for three- and four-band 25 and 50 nm Gaussian spectra are presented and analyzed, together with mixed 4-LED spectra that were optimized in the same way. In all cases, the simulated sources were shown to provide color rendering of such quality that ΔE00av ≤ 2.24 units. Such white-light sources would likely find wide acceptance in numerous lighting applications.

  7. Determination of Ergot Alkaloids: Purity and Stability Assessment of Standards and Optimization of Extraction Conditions for Cereal Samples

    DEFF Research Database (Denmark)

    Krska, R.; Berthiller, F.; Schuhmacher, R.

    2008-01-01

    as those that are the most common and physiologically active. The purity of the standards was investigated by means of liquid chromatography with diode array detection, electrospray ionization, and time-of-flight mass spectrometry (LC-DAD-ESI-TOF-MS). All of the standards assessed showed purity levels...... (PSA) before LC/MS/MS. Based on the results obtained from these optimization studies, a mixture of acetonitrile with ammonium carbonate buffer was used as extraction solvent, as recoveries for all analyzed ergot alkaloids were significantly higher than those with the other solvents. Different sample...

  8. Python pocket reference, version 2.4

    CERN Document Server

    Lutz, Mark

    2005-01-01

    Python is optimized for quality, productivity, portability, and integration. Hundreds of thousands of Python developers around the world rely on Python for general-purpose tasks, Internet scripting, systems programming, user interfaces, and product customization. Available on all major computing platforms, including commercial versions of Unix, Linux, Windows, and Mac OS X, Python is portable, powerful and remarkable easy to use. With its convenient, quick-reference format, Python Pocket Reference, 3rd Edition is the perfect on-the-job reference. More importantly, it's now been refreshed

  9. Thermal conductivity and electrical resistivity standard reference materials: tungsten SRM's 730 and 799, from 4 to 30000K. Final report

    International Nuclear Information System (INIS)

    Hust, J.G.; Giarratano, P.J.

    1975-09-01

    A historical review of the development of thermophysical Standard Reference Materials, SRM's, is given and selection criteria of SRM's are listed. Thermal conductivity and electrical resistivity data for arc cast and sintered tungsten are compiled, analyzed, and correlated. Recommended values of thermal conductivity (SRM 730) and electrical resistivity (SRM 799) for these lots of tungsten are presented for the range 4 to 3000 0 K

  10. Adaptively optimizing stochastic resonance in visual system

    Science.gov (United States)

    Yang, Tao

    1998-08-01

    Recent psychophysics experiment has showed that the noise strength could affect the perceived image quality. This work gives an adaptive process for achieving the optimal perceived image quality in a simple image perception array, which is a simple model of an image sensor. A reference image from memory is used for constructing a cost function and defining the optimal noise strength where the cost function gets its minimum point. The reference image is a binary image, which is used to define the background and the object. Finally, an adaptive algorithm is proposed for searching the optimal noise strength. Computer experimental results show that if the reference image is a thresholded version of the sub-threshold input image then the output of the sensor array gives an optimal output, in which the background and the object have the biggest contrast. If the reference image is different from a thresholded version of the sub-threshold input image then the output usually gives a sub-optimal contrast between the object and the background.

  11. Optimization of patient radiation protection in pelvic X-ray examination in Ghana.

    Science.gov (United States)

    Ofori, Eric K; Antwi, William K; Scutt, Diane N; Ward, Matt

    2012-07-05

    Pelvis X-ray examinations inevitably involve exposure of the gonads to ionizing radiation. In line with the principle of keeping doses as low as reasonably practicable (ALARP), accurate patient dose measurement is vital if we are to ascertain that these exposures are fully optimized. The study aimed to provide patient dose estimates for pelvis examination being undertaken at 10 separate hospitals in Ghana in order to provide an initial quantitative indication of each site's typically achievable radiation safety and quality standards. The method employed was adapted from established methods and peer reviewed literature, such as the International Atomic Energy Agency (IAEA) publications on optimization of the radiological protection of patients undergoing radiography, fluoroscopy, and computed tomography examinations in some countries in Africa, Asia, and Eastern Europe. Dose measurements were calculated on 323 patients (137 (42%) male, 186 (58%) female, ages, 38.56 yr ± 9.0; range 20-68). The entrance surface dose (ESD) was determined by an indirect method, using the patient's anatomical data and exposure parameters utilized for the specific examination. The Quality Assurance Dose Database software (QADDs) developed by Integrated Radiological Services Ltd. in Liverpool, UK was used to generate the ESD values. The study identified variations in the technique factors used compared with the recommendations in the European Commission (EC) quality criteria. Eighty percent of the hospitals recorded lower ESD values below IAEA recommended diagnostic reference levels (10 mGy) and 40% of the hospitals exceeded the UK national reference value (4 mGy). However, one hospital consistently recorded higher ESDs than the other hospitals. The variations in the data recorded demonstrate the importance of creating awareness by the radiographic staff on quality assurance and standardization of protocols to ensure satisfactory standards and optimized radiation dose to patients and

  12. Structure factor of liquid alkali metals using a classical-plasma reference system

    Science.gov (United States)

    Pastore, G.; Tosi, M. P.

    1984-06-01

    This paper presents calculations of the liquid structure factor of the alkali metals near freezing, starting from the classical plasma of bare ions as reference liquid. The indirect ion-ion interaction arising from electronic screening is treated by an optimized random phase approximation (ORPA), imposing physical requirements as in the original ORPA scheme developed by Weeks, Chandler and Andersen for liquids with strongly repulsive core potentials. A comparison of the results with computer simulation data for a model of liquid rubidium shows that the present approach overcomes the well-known difficulties met in applying to these metals the standard ORPA based on a reference liquid of neutral hard spheres. The optimization scheme is also shown to be equivalent to a reduction of the range of the indirect interaction in momentum space, as proposed empirically in an earlier work. Comparison with experiment for the other alkalis shows that a good overall representation of the data can be obtained for sodium, potassium and cesium, but not for lithium, when one uses a very simple form of the electron-ion potential adjusted to the liquid compressibility. The small-angle scattering region is finally examined more carefully in the light of recent data of Waseda, with a view to possible refinements of the pseudopotential model.

  13. A reference case for economic evaluations in osteoarthritis: an expert consensus article from the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis (ESCEO).

    Science.gov (United States)

    Hiligsmann, Mickaël; Cooper, Cyrus; Guillemin, Francis; Hochberg, Marc C; Tugwell, Peter; Arden, Nigel; Berenbaum, Francis; Boers, Maarten; Boonen, Annelies; Branco, Jaime C; Maria-Luisa, Brandi; Bruyère, Olivier; Gasparik, Andrea; Kanis, John A; Kvien, Tore K; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Pinedo-Villanueva, Rafael; Pinto, Daniel; Reiter-Niesert, Susanne; Rizzoli, René; Rovati, Lucio C; Severens, Johan L; Silverman, Stuart; Reginster, Jean-Yves

    2014-12-01

    General recommendations for a reference case for economic studies in rheumatic diseases were published in 2002 in an initiative to improve the comparability of cost-effectiveness studies in the field. Since then, economic evaluations in osteoarthritis (OA) continue to show considerable heterogeneity in methodological approach. To develop a reference case specific for economic studies in OA, including the standard optimal care, with which to judge new pharmacologic and non-pharmacologic interventions. Four subgroups of an ESCEO expert working group on economic assessments (13 experts representing diverse aspects of clinical research and/or economic evaluations) were charged with producing lists of recommendations that would potentially improve the comparability of economic analyses in OA: outcome measures, comparators, costs and methodology. These proposals were discussed and refined during a face-to-face meeting in 2013. They are presented here in the format of the recommendations of the recently published Consolidated Health Economic Evaluation Reporting Standards (CHEERS) statement, so that an initiative on economic analysis methodology might be consolidated with an initiative on reporting standards. Overall, three distinct reference cases are proposed, one for each hand, knee and hip OA; with diagnostic variations in the first two, giving rise to different treatment options: interphalangeal or thumb-based disease for hand OA and the presence or absence of joint malalignment for knee OA. A set of management strategies is proposed, which should be further evaluated to help establish a consensus on the "standard optimal care" in each proposed reference case. The recommendations on outcome measures, cost itemisation and methodological approaches are also provided. The ESCEO group proposes a set of disease-specific recommendations on the conduct and reporting of economic evaluations in OA that could help the standardisation and comparability of studies that evaluate

  14. The Improvement of Particle Swarm Optimization: a Case Study of Optimal Operation in Goupitan Reservoir

    Science.gov (United States)

    Li, Haichen; Qin, Tao; Wang, Weiping; Lei, Xiaohui; Wu, Wenhui

    2018-02-01

    Due to the weakness in holding diversity and reaching global optimum, the standard particle swarm optimization has not performed well in reservoir optimal operation. To solve this problem, this paper introduces downhill simplex method to work together with the standard particle swarm optimization. The application of this approach in Goupitan reservoir optimal operation proves that the improved method had better accuracy and higher reliability with small investment.

  15. Measurement of the fluorine content of three NBS standard reference materials by use of the /sup 19/F(p, p'. gamma. )/sup 19/F reaction

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, A L; Kraner, H W; Shroy, R E; Jones, K W [Brookhaven National Lab., Upton, NY (USA)

    1984-08-01

    The fluorine contents of National Bureau of Standards (NBS) Standard Reference Materials (SRM) 91, opal glass; 120b, phosphate rock; and 2671a, freeze-dried urine; have been measured using the /sup 19/F(p,p'..gamma..)/sup 19/F reaction at a proton energy of 3.1 MeV. The results are in good agreement with the values certified by the NBS.

  16. Development of the neutron reference calibration field using a 252Cf standard source surrounded with PMMA moderators

    International Nuclear Information System (INIS)

    Yoshida, T.; Kanai, K.; Tsujimura, N.

    2002-01-01

    The authors developed the neutron reference calibration fields using a 252 Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the 252 Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO 2 -UO 2 mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments

  17. The Optimal Design Method and Standardized Mathematical Model of Tooth Profile Modification of Spur Gear

    Directory of Open Access Journals (Sweden)

    Wenjie Mei

    2016-01-01

    Full Text Available The paper reports a tooth profile modification method of spur gear. After establishing a standardized mathematical model for optimized tooth profile and simulating meshing process with ANSYS finite element analysis, we obtained 625 groups of gear models with different modification parameters. The group with minimum transmission errors owns the optimal parameters. Genetic algorithm was adopted in the entire process for the purpose of reducing the variation of transmission errors in meshing process. The arc and parabolic modification were doing the same processing. After comparing the transmission errors fluctuation produced by the meshing process of gear of nonmodification with arc modification and parabolic modification, we found that the best modification effects of arc modification and parabolic modification were both reduced by 90%. The modification method makes the gear drive process more stable and efficient, and it is also promising in general application for gear drive.

  18. Optimism and Well-Being

    Science.gov (United States)

    Reivich, Karen

    2010-01-01

    Dictionary definitions of optimism encompass two related concepts. The first of these is a hopeful disposition or a conviction that good will ultimately prevail. The second, broader conception of optimism refers to the belief, or the inclination to believe, that the world is the best of all possible worlds. In psychological research, optimism has…

  19. New reference charts for testicular volume in Dutch children and adolescents allow the calculation of standard deviation scores.

    Science.gov (United States)

    Joustra, Sjoerd D; van der Plas, Evelyn M; Goede, Joery; Oostdijk, Wilma; Delemarre-van de Waal, Henriette A; Hack, Wilfried W M; van Buuren, Stef; Wit, Jan M

    2015-06-01

    Accurate calculations of testicular volume standard deviation (SD) scores are not currently available. We constructed LMS-smoothed age-reference charts for testicular volume in healthy boys. The LMS method was used to calculate reference data, based on testicular volumes from ultrasonography and Prader orchidometer of 769 healthy Dutch boys aged 6 months to 19 years. We also explored the association between testicular growth and pubic hair development, and data were compared to orchidometric testicular volumes from the 1997 Dutch nationwide growth study. The LMS-smoothed reference charts showed that no revision of the definition of normal onset of male puberty - from nine to 14 years of age - was warranted. In healthy boys, the pubic hair stage SD scores corresponded with testicular volume SD scores (r = 0.394). However, testes were relatively small for pubic hair stage in Klinefelter's syndrome and relatively large in immunoglobulin superfamily member 1 deficiency syndrome. The age-corrected SD scores for testicular volume will aid in the diagnosis and follow-up of abnormalities in the timing and progression of male puberty and in research evaluations. The SD scores can be compared with pubic hair SD scores to identify discrepancies between cell functions that result in relative microorchidism or macroorchidism. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  20. Different reference BMDs affect the prevalence of osteoporosis.

    Science.gov (United States)

    Jung, Ki Jin; Chung, Chin Youb; Park, Moon Seok; Kwon, Soon-Sun; Moon, Sang Young; Lee, In Hyeok; Kim, Ka Hyun; Lee, Kyoung Min

    2016-05-01

    The T score represents the degree of deviation from the peak bone mineral density (BMD) (reference standard) in a population. Little has been investigated concerning the age at which the BMD reaches the peak value and how we should define the reference standard BMD in terms of age ranges. BMDs of 9,800 participants were analyzed from the Korean National Health and Nutrition Examination Survey database. Five reference standards were defined: (1) the reference standard of Japanese young adults provided by the dual-energy X-ray absorptiometry machine manufacturer, (2) peak BMD of the Korean population evaluated by statistical analysis (second-order polynomial regression models), (3) BMD of subjects aged 20-29 years, (4) BMD of subjects aged 20-39 years, and (5) BMD of subjects aged 30-39 years. T-scores from the five reference standards were calculated, and the prevalence of osteoporosis was evaluated and compared for males and females separately. The peak BMD in the polynomial regression model was achieved at 26 years in males and 36 years in females in the total hip, at 20 years in males and 27 years in females in the femoral neck, and at 20 years in males and 30 years in females in the lumbar spine. The prevalence of osteoporosis over the age of 50 years showed significant variation of up to two fold depending on the reference standards adopted. The age at which peak BMD was achieved was variable according to the gender and body sites. A consistent definition of peak BMD needs to be established in terms of age ranges because this could affect the prevalence of osteoporosis and healthcare policies.

  1. OTTER: An Optimized Transit Tool And Easy Reference

    Science.gov (United States)

    2016-03-01

    TRANSIT TOOL AND EASY REFERENCE Warren Korban Blackburn Lieutenant Commander, United States Navy B.A., Thomas Edison State College, 2003...B.S.A.S.T., Thomas Edison State College, 2004 Submitted in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE IN...application. Each of these technologies adds to the efficiency of the fleet. As RADM Thomas Eccles said, “No single technology will enable the Navy to

  2. BATING A REFERENCE INSTALLATION BASED ON CONTROLLED-POTENTIAL COULOMETRY METOD IN THE FRAME OF IMPROVING THE STATE PRIMARY STANDARD GET 176 AND ITS MEASUREMENT CAPABILITIES

    Directory of Open Access Journals (Sweden)

    V. M. Zyskin

    2016-01-01

    Full Text Available The results of developing of reference installation, based on a controlled-potential coulometry, in the frame of improving the State primary standard of the units of mass (molar fraction and mass (molar concentration of a component in the liquid and solid substances and materials GET 176 are presented. The physical principles of controlled-potential coulometry, content and metrological characteristics of the developed installation are considered. Measurement results of copper, iron and lead contents in the certified reference materials of metals' solutions and CRM of brass produced by BAM, Germany, obtained using reference installation are given.

  3. SHORT COMMUNICATION: Transportable Zener-diode Voltage Standard

    Science.gov (United States)

    Karpov, O. V.; Shulga, V. M.; Shakirzyanova, F. R.; Sarandi, A. E.

    1994-01-01

    Five transportable Zener-diode dc voltage standards have been developed, fabricated and investigated at the NPO VNIIFTRI. The standards were designed to transfer the unit of electromotive force (emf) from Josephson reference standards to measuring instruments. Following the results of these investigations, standard N 02 has been used for intercomparison of the Russian Josephson reference standards.

  4. Discussion on accuracy of weld residual stress measurement by neutron diffraction. Influence of strain free reference

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Akita, Koichi

    2012-01-01

    It is required to evaluate a strain-free reference, α 0 , to perform accurate stress measurement using neutron diffraction. In this study, accuracy of neutron stress measurement was quantitatively discussed from α 0 evaluations on a dissimilar metal butt-weld between a type 304 austenitic stainless steel and an A533B low alloy ferritic steel. A strain-free standard specimen and a sliced specimen with 10 mm thickness taken from the dissimilar metal butt-weld were utilized. In the lattice constant evaluation using the standard specimen, average lattice constant derived from multiple hkl reflections was evaluated as the stress-free reference with cancelling out an intergranular strain. Comparing lattice constant distributions in each reflection with average lattice constant distribution in the standard specimen, αFe211 and γFe311 reflections were judged as a suitable reflection for neutron strain measurement to reduce intergranular strain effects. Residual stress distribution in the sliced specimen evaluated using α 0 measured here exhibited higher accuracy than that measured using strain gauges. On the other hand, α 0 distributions were evaluated using the sliced specimen under the plane-stress condition. Existence of slight longitudinal residual stresses near the weld center decreased accuracy of the α 0 evaluations, which means that it is required to optimize the thickness of the sliced specimen for accurate α 0 evaluation under plane strain condition. As a conclusion of this study, it was confirmed that procedures of accurate α 0 evaluation, optimization of the measurement condition, and multiple evaluations on the results play an important role to improve accuracy of the residual stress measurement using neutron diffraction. (author)

  5. KM-FCM: A fuzzy clustering optimization algorithm based on Mahalanobis distance

    Directory of Open Access Journals (Sweden)

    Zhiwen ZU

    2018-04-01

    Full Text Available The traditional fuzzy clustering algorithm uses Euclidean distance as the similarity criterion, which is disadvantageous to the multidimensional data processing. In order to solve this situation, Mahalanobis distance is used instead of the traditional Euclidean distance, and the optimization of fuzzy clustering algorithm based on Mahalanobis distance is studied to enhance the clustering effect and ability. With making the initialization means by Heuristic search algorithm combined with k-means algorithm, and in terms of the validity function which could automatically adjust the optimal clustering number, an optimization algorithm KM-FCM is proposed. The new algorithm is compared with FCM algorithm, FCM-M algorithm and M-FCM algorithm in three standard data sets. The experimental results show that the KM-FCM algorithm is effective. It has higher clustering accuracy than FCM, FCM-M and M-FCM, recognizing high-dimensional data clustering well. It has global optimization effect, and the clustering number has no need for setting in advance. The new algorithm provides a reference for the optimization of fuzzy clustering algorithm based on Mahalanobis distance.

  6. Persistent Web References – Best Practices and New Suggestions

    DEFF Research Database (Denmark)

    Zierau, Eld; Nyvang, Caroline; Kromann, Thomas Hvid

    In this paper, we suggest adjustments to best practices for persistent web referencing; adjustments that aim at preservation and long time accessibility of web referenced resources in general, but with focus on web references in web archives. Web referencing is highly relevant and crucial...... refer to archive URLs which depends on the web archives access implementations. A major part of the suggested adjustments is a new web reference standard for archived web references (called wPID), which is a supplement to the current practices. The purpose of the standard is to support general, global...

  7. Optimizing personalized normative feedback: the use of gender-specific referents.

    Science.gov (United States)

    Lewis, Melissa A; Neighbors, Clayton

    2007-03-01

    Many brief interventions include personalized normative feedback (PNF) using gender-specific or gender-neutral referents. Several theories suggest that information pertaining to more socially proximal referents should have greater influence on one's behavior compared with more socially distal referents. The current research evaluated whether gender specificity of the normative referent employed in PNF related to intervention efficacy. Following baseline assessment, 185 college students (45.2% women) were randomly assigned to one of three intervention conditions: gender-specific feedback, gender-neutral feedback, or assessment-only control. Immediately after completing measures of perceived norms, alcohol consumption, and gender identity, participants in the gender-neutral and gender-specific intervention conditions were provided with computerized information detailing their own drinking behavior, their perceptions of student drinking, and actual student drinking. After a 1-month follow-up, the results indicated that normative feedback was effective in changing perceived norms and reducing alcohol consumption for both intervention groups for women and men. The results provide support, however, for changes in perceived gender-specific norms as a mediator of the effects of normative feedback on reduced drinking behavior for women only. Additionally, gender-specific feedback was found to be more effective for women higher in gender identity, relative to the gender-neutral feedback. A post-assessment follow-up telephone survey administered to assess potential demand characteristics corroborated the intervention effects. Results extend previous research documenting efficacy of computer delivered PNF. Gender specificity and gender identity appear to be important elements to consider for PNF intervention efficacy for women.

  8. Evaluation of Method-Specific Extraction Variability for the Measurement of Fatty Acids in a Candidate Infant/Adult Nutritional Formula Reference Material.

    Science.gov (United States)

    Place, Benjamin J

    2017-05-01

    To address community needs, the National Institute of Standards and Technology has developed a candidate Standard Reference Material (SRM) for infant/adult nutritional formula based on milk and whey protein concentrates with isolated soy protein called SRM 1869 Infant/Adult Nutritional Formula. One major component of this candidate SRM is the fatty acid content. In this study, multiple extraction techniques were evaluated to quantify the fatty acids in this new material. Extraction methods that were based on lipid extraction followed by transesterification resulted in lower mass fraction values for all fatty acids than the values measured by methods utilizing in situ transesterification followed by fatty acid methyl ester extraction (ISTE). An ISTE method, based on the identified optimal parameters, was used to determine the fatty acid content of the new infant/adult nutritional formula reference material.

  9. Dose evaluation and establishment of reference levels in activity for nuclear medicine

    International Nuclear Information System (INIS)

    Ribeiro, Julio Cesar de Souza

    2017-01-01

    The International Commission on Radiation Protection (ICRP) has emphasized the importance of accurately determining the mean dose levels, or administered activity, received by the patients for each medical procedure that uses ionizing radiation. However, the number of bibliographic references addressing the need to know and optimize these levels is insufficient, or rather limited, which may lead to non-standardizes techniques, a lack of exposures control, and also the increase of associated radiological risks of these procedures. In this context, a software in Visual Basic® of Microsoft© language was developed whose function is to elaborate a method of obtaining the Reference Levels in Activity (RLA) for nuclear medicine patients by determining the third quartile of the examinations carried out. The program also allows obtaining absorbed dose values in critical organs based on patient specificities as age, sex and Body Mass Index (BMI) in order to evaluate the risk involved in each procedure. The main nuclear medicine diagnostic procedures were evaluated through the database of two public hospitals and a private clinic, obtaining the NRAs of each facility, where the software was validated by comparison with the traditionally accepted calculation methods. Due to the results obtained in each installation, in addition to NRA determination, gaps in treatment capacities and unjustified dose variations for the same procedure were identified, indicating the need for optimization. Thus, the developed program is able to provide the estimated values of effective and absorbed doses involved in each procedure, for each patient, providing reference values for nuclear medicine field, not available in the national scenario so far. (author)

  10. Comparability of reference values

    International Nuclear Information System (INIS)

    Rossbach, M.; Stoeppler, M.

    1993-01-01

    Harmonization of certified values in Reference Materials (RMs) can be carried out by applying nuclear analytical techniques to RMs of various matrix types and concentration levels. Although RMs generally should not be used as primary standards the cross evaluation of concentrations in RMs leads to better compatibility of reference values and thus to a greater agreement between analytical results from different laboratories using these RMs for instrument calibration and quality assurance. (orig.)

  11. Updating OSHA Standards Based on National Consensus Standards; Eye and Face Protection. Final rule.

    Science.gov (United States)

    2016-03-25

    On March 13, 2015, OSHA published in the Federal Register a notice of proposed rulemaking (NPRM) to revise its eye and face protection standards for general industry, shipyard employment, marine terminals, longshoring, and construction by updating the references to national consensus standards approved by the American National Standards Institute (ANSI). OSHA received no significant objections from commenters and therefore is adopting the amendments as proposed. This final rule updates the references in OSHA's eye and face standards to reflect the most recent edition of the ANSI/International Safety Equipment Association (ISEA) eye and face protection standard. It removes the oldest-referenced edition of the same ANSI standard. It also amends other provisions of the construction eye and face protection standard to bring them into alignment with OSHA's general industry and maritime standards.

  12. Statistical considerations for harmonization of the global multicenter study on reference values.

    Science.gov (United States)

    Ichihara, Kiyoshi

    2014-05-15

    The global multicenter study on reference values coordinated by the Committee on Reference Intervals and Decision Limits (C-RIDL) of the IFCC was launched in December 2011, targeting 45 commonly tested analytes with the following objectives: 1) to derive reference intervals (RIs) country by country using a common protocol, and 2) to explore regionality/ethnicity of reference values by aligning test results among the countries. To achieve these objectives, it is crucial to harmonize 1) the protocol for recruitment and sampling, 2) statistical procedures for deriving the RI, and 3) test results through measurement of a panel of sera in common. For harmonized recruitment, very lenient inclusion/exclusion criteria were adopted in view of differences in interpretation of what constitutes healthiness by different cultures and investigators. This policy may require secondary exclusion of individuals according to the standard of each country at the time of deriving RIs. An iterative optimization procedure, called the latent abnormal values exclusion (LAVE) method, can be applied to automate the process of refining the choice of reference individuals. For global comparison of reference values, test results must be harmonized, based on the among-country, pair-wise linear relationships of test values for the panel. Traceability of reference values can be ensured based on values assigned indirectly to the panel through collaborative measurement of certified reference materials. The validity of the adopted strategies is discussed in this article, based on interim results obtained to date from five countries. Special considerations are made for dissociation of RIs by parametric and nonparametric methods and between-country difference in the effect of body mass index on reference values. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Optimising the Number of Replicate- Versus Standard Measurements for Carbonate Clumped Isotope Thermometry

    Science.gov (United States)

    Kocken, I.; Ziegler, M.

    2017-12-01

    Clumped isotope measurements on carbonates are a quickly developing and promising palaeothermometry proxy1-3. Developments in the field have brought down the necessary sample amount and improved the precision and accuracy of the measurements. The developments have included inter-laboratory comparison and the introduction of an absolute reference frame4, determination of acid fractionation effects5, correction for the pressure baseline6, as well as improved temperature calibrations2, and most recently new approaches to improve efficiency in terms of sample gas usage7. However, a large-scale application of clumped isotope thermometry is still hampered by required large sample amounts, but also the time-consuming analysis. In general, a lot of time is goes into the measurement of standards. Here we present a study on the optimal ratio between standard- and sample measurements using the Kiel Carbonate Device method. We also consider the optimal initial signal intensity. We analyse ETH-standard measurements from several months to determine the measurement regime with the highest precision and optimised measurement time management.References 1. Eiler, J. M. Earth Planet. Sci. Lett. 262, 309-327 (2007).2. Kelson, J. R., et al. Geochim. Cosmochim. Acta 197, 104-131 (2017).3. Kele, S. et al. Geochim. Cosmochim. Acta 168, 172-192 (2015).4. Dennis, K. J. et al. Geochim. Cosmochim. Acta 75, 7117-7131 (2011).5. Müller, I. A. et al. Chem. Geol. 449, 1-14 (2017).6. Meckler, A. N. et al. Rapid Commun. Mass Spectrom. 28, 1705-1715 (2014).7. Hu, B. et al. Rapid Commun. Mass Spectrom. 28, 1413-1425 (2014).

  14. Optimization of multi-objective micro-grid based on improved particle swarm optimization algorithm

    Science.gov (United States)

    Zhang, Jian; Gan, Yang

    2018-04-01

    The paper presents a multi-objective optimal configuration model for independent micro-grid with the aim of economy and environmental protection. The Pareto solution set can be obtained by solving the multi-objective optimization configuration model of micro-grid with the improved particle swarm algorithm. The feasibility of the improved particle swarm optimization algorithm for multi-objective model is verified, which provides an important reference for multi-objective optimization of independent micro-grid.

  15. Uranium reference materials

    International Nuclear Information System (INIS)

    Donivan, S.; Chessmore, R.

    1987-07-01

    The Technical Measurements Center has prepared uranium mill tailings reference materials for use by remedial action contractors and cognizant federal and state agencies. Four materials were prepared with varying concentrations of radionuclides, using three tailings materials and a river-bottom soil diluent. All materials were ground, dried, and blended thoroughly to ensure homogeneity. The analyses on which the recommended values for nuclides in the reference materials are based were performed, using independent methods, by the UNC Geotech (UNC) Chemistry Laboratory, Grand Junction, Colorado, and by C.W. Sill (Sill), Idaho National Engineering Laboratory, Idaho Falls, Idaho. Several statistical tests were performed on the analytical data to characterize the reference materials. Results of these tests reveal that the four reference materials are homogeneous and that no large systematic bias exists between the analytical methods used by Sill and those used by TMC. The average values for radionuclides of the two data sets, representing an unbiased estimate, were used as the recommended values for concentrations of nuclides in the reference materials. The recommended concentrations of radionuclides in the four reference materials are provided. Use of these reference materials will aid in providing uniform standardization among measurements made by remedial action contractors. 11 refs., 9 tabs

  16. New International Reference Standards of Voltage and Resistance.

    Science.gov (United States)

    Sirvastava, V. P.

    1991-01-01

    The introduction of the quantum standards of resistance and voltage, based on the Quantum Hall Effect (QHE) and the Josephson Effect, can be used to establish highly reproducible and uniform representations of the ohm and volt worldwide. Discussed are the QHE and the Josephson Effect. (KR)

  17. 77 FR 37587 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-06-22

    ... Z89.1-2003 as Appendix E, to the main text. Adds ``ASTM E1164-02 Colorimetry--Standard Practice for... National complete citations for standards on Standards Referred to in This colorimetry, headforms, and...

  18. 77 FR 37617 - Updating OSHA Standards Based on National Consensus Standards; Head Protection

    Science.gov (United States)

    2012-06-22

    ... Z89.1-2003 as Appendix E, to the main text. Adds ``ASTM E1164-02 Colorimetry--Standard Practice for... National complete citations for standards on Standards Referred to in This colorimetry, headforms, and...

  19. DAKOTA : a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis. Version 5.0, user's reference manual.

    Energy Technology Data Exchange (ETDEWEB)

    Eldred, Michael Scott; Dalbey, Keith R.; Bohnhoff, William J.; Adams, Brian M.; Swiler, Laura Painton; Hough, Patricia Diane (Sandia National Laboratories, Livermore, CA); Gay, David M.; Eddy, John P.; Haskell, Karen H.

    2010-05-01

    The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic finite element methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a reference manual for the commands specification for the DAKOTA software, providing input overviews, option descriptions, and example specifications.

  20. Recent references

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1991-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Any reader who finds errors in the keyword descriptions is urged to report them to the National Nuclear Data Center so that the master NSR file can be corrected. In 1966, the first collection of Recent References was published as a separate issue of Nuclear Data Sheets. Every four months since 1970, a similar indexed bibliography to new nuclear experiments has been prepared from additions to the NSR file and published. Beginning in 1978, Recent References was cumulated annually, with the third issue completely superseding the two issues previously published during a given year. Due to publication policy changes, cumulation of Recent Reference was discontinued in 1986. The volume and issue number of all the cumulative issues published to date are given. NNDC will continue to respond to individual requests for special bibliographies on nuclear physics topics, in addition to those easily obtained from Recent References. If the required information is available from the keyword string, a reference list can be prepared automatically from the computer files. This service can be provided on request, in exchange for the timely communication of new nuclear physics results (e.g., preprints). A current copy of the NSR file may also be obtained in a standard format on magnetic tape from NNDC. Requests for special searches of the NSR file may also be directed to the National Nuclear Data Center

  1. 78 FR 35559 - Updating OSHA Standards Based on National Consensus Standards; Signage

    Science.gov (United States)

    2013-06-13

    ...; Signage AGENCY: Occupational Safety and Health Administration (OSHA), Department of Labor. ACTION: Direct... signage standards by adding references to the latest versions of the American National Standards Institute... earlier ANSI standards, ANSI Z53.1-1967, Z35.1-1968 and Z35.2-1968, in its signage standards, thereby...

  2. Standardization of UV LED measurements

    Science.gov (United States)

    Eppeldauer, G. P.; Larason, T. C.; Yoon, H. W.

    2015-09-01

    Traditionally used source spectral-distribution or detector spectral-response based standards cannot be applied for accurate UV LED measurements. Since the CIE standardized rectangular-shape spectral response function for UV measurements cannot be realized with small spectral mismatch when using filtered detectors, the UV measurement errors can be several times ten percent or larger. The UV LEDs produce broadband radiation and both their peaks or spectral bandwidths can change significantly. The detectors used for the measurement of these LEDs also have different spectral bandwidths. In the discussed example, where LEDs with 365 nm peak are applied for fluorescent crack-recognition using liquid penetrant (non-destructive) inspection, the broadband radiometric LED (signal) measurement procedure is standardized. A UV LED irradiance-source was calibrated against an FEL lamp standard to determine its spectral irradiance. The spectral irradiance responsivity of a reference UV meter was also calibrated. The output signal of the reference UV meter was calculated from the spectral irradiance of the UV source and the spectral irradiance responsivity of the reference UV meter. From the output signal, both the integrated irradiance (in the reference plane of the reference meter) and the integrated responsivity of the reference meter were determined. Test UV meters calibrated for integrated responsivity against the reference UV meter, can be used to determine the integrated irradiance from a field UV source. The obtained 5 % (k=2) measurement uncertainty can be decreased when meters with spectral response close to a constant value are selected.

  3. EFFECTS OF RELIGIOUS VERSUS STANDARD COGNITIVE-BEHAVIORAL THERAPY ON OPTIMISM IN PERSONS WITH MAJOR DEPRESSION AND CHRONIC MEDICAL ILLNESS.

    Science.gov (United States)

    Koenig, Harold G; Pearce, Michelle J; Nelson, Bruce; Daher, Noha

    2015-11-01

    We compared the effectiveness of religiously integrated cognitive behavioral therapy (RCBT) versus standard CBT (SCBT) on increasing optimism in persons with major depressive disorder (MDD) and chronic medical illness. Participants aged 18-85 were randomized to either RCBT (n = 65) or SCBT (n = 67) to receive ten 50-min sessions remotely (94% by telephone) over 12 weeks. Optimism was assessed at baseline, 12 and 24 weeks by the Life Orientation Test-Revised. Religiosity was assessed at baseline using a 29-item scale composed of religious importance, individual religious practices, intrinsic religiosity, and daily spiritual experiences. Mixed effects growth curve models were used to compare the effects of treatment group on trajectory of change in optimism. In the intention-to-treat analysis, both RCBT and SCBT increased optimism over time, although there was no significant difference between treatment groups (B = -0.75, SE = 0.57, t = -1.33, P = .185). Analyses in the highly religious and in the per protocol analysis indicated similar results. Higher baseline religiosity predicted an increase in optimism over time (B = 0.07, SE = 0.02, t = 4.12, P optimism predicted a faster decline in depressive symptoms over time (B = -0.61, SE = 0.10, t = -6.30, P optimism in persons with MDD and chronic medical illness. While baseline religiosity does not moderate this effect, religiosity predicts increases in optimism over time independent of treatment group. © 2015 Wiley Periodicals, Inc.

  4. Assessing the economic value of co-optimized grid-scale energy storage investments in supporting high renewable portfolio standards

    International Nuclear Information System (INIS)

    Go, Roderick S.; Munoz, Francisco D.; Watson, Jean-Paul

    2016-01-01

    Highlights: • We present a MILP to co-optimize generation, transmission, and storage investments. • We find significant value in co-optimized storage via investment deferrals. • Operational savings from bulk services are small relative to investment deferrals. • Co-optimized energy storage significantly reduces prices associated with RPS. - Abstract: Worldwide, environmental regulations such as Renewable Portfolio Standards (RPSs) are being broadly adopted to promote renewable energy investments. With corresponding increases in renewable energy deployments, there is growing interest in grid-scale energy storage systems (ESS) to provide the flexibility needed to efficiently deliver renewable power to consumers. Our contribution in this paper is to introduce a unified generation, transmission, and bulk ESS expansion planning model subject to an RPS constraint, formulated as a two-stage stochastic mixed-integer linear program (MILP) optimization model, which we then use to study the impact of co-optimization and evaluate the economic interaction between investments in these three asset classes in achieving high renewable penetrations. We present numerical case studies using the 24-bus IEEE RTS-96 test system considering wind and solar as available renewable energy resources, and demonstrate that up to $180 million/yr in total cost savings can result from the co-optimization of all three assets, relative to a situation in which no ESS investment options are available. Surprisingly, we find that co-optimized bulk ESS investments provide significant economic value through investment deferrals in transmission and generation capacity, but very little savings in operational cost. Finally, we observe that planning transmission and generation infrastructure first and later optimizing ESS investments—as is common in industry—captures at most 1.7% ($3 million/yr) of the savings that result from co-optimizing all assets simultaneously.

  5. Development of the neutron reference calibration field using a {sup 252}Cf standard source surrounded with PMMA moderators

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, T.; Kanai, K.; Tsujimura, N. [Japan Nuclear Cycle Development Institute, Ibaraki-ken (Japan)

    2002-07-01

    The authors developed the neutron reference calibration fields using a {sup 252} Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the {sup 252} Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO{sub 2}-UO{sub 2} mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments.

  6. Optimal PMU Placement By Improved Particle Swarm Optimization

    DEFF Research Database (Denmark)

    Rather, Zakir Hussain; Liu, Leo; Chen, Zhe

    2013-01-01

    This paper presents an improved method of binary particle swarm optimization (IBPSO) technique for optimal phasor measurement unit (PMU) placement in a power network for complete system observability. Various effective improvements have been proposed to enhance the efficiency and convergence rate...... of conventional particle swarm optimization method. The proposed method of IBPSO ensures optimal PMU placement with and without consideration of zero injection measurements. The proposed method has been applied to standard test systems like 17 bus, IEEE 24-bus, IEEE 30-bus, New England 39-bus, IEEE 57-bus system...

  7. Dependability of self-optimizing mechatronic systems

    CERN Document Server

    Rammig, Franz; Schäfer, Wilhelm; Sextro, Walter

    2014-01-01

    Intelligent technical systems, which combine mechanical, electrical and software engineering with control engineering and advanced mathematics, go far beyond the state of the art in mechatronics and open up fascinating perspectives. Among these systems are so-called self-optimizing systems, which are able to adapt their behavior autonomously and flexibly to changing operating conditions. Self-optimizing systems create high value for example in terms of energy and resource efficiency as well as reliability. The Collaborative Research Center 614 "Self-optimizing Concepts and Structures in Mechanical Engineering" pursued the long-term aim to open up the active paradigm of self-optimization for mechanical engineering and to enable others to develop self-optimizing systems. This book is directed to researchers and practitioners alike. It provides a design methodology for the development of self-optimizing systems consisting of a reference process, methods, and tools. The reference process is divided into two phase...

  8. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    Science.gov (United States)

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  9. 47 CFR 90.379 - ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard).

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard... Communications Service (dsrcs) § 90.379 ASTM E2213-03 DSRC Standard (ASTM-DSRC Standard). Roadside Units... incorporated by reference: American Society for Testing and Materials (ASTM) E2213-03, “Standard Specification...

  10. Practical utilization of recombinant AAV vector reference standards: focus on vector genomes titration by free ITR qPCR

    Directory of Open Access Journals (Sweden)

    Susan D'Costa

    2016-01-01

    Full Text Available Clinical trials using recombinant adeno-associated virus (rAAV vectors have demonstrated efficacy and a good safety profile. Although the field is advancing quickly, vector analytics and harmonization of dosage units are still a limitation for commercialization. AAV reference standard materials (RSMs can help ensure product safety by controlling the consistency of assays used to characterize rAAV stocks. The most widely utilized unit of vector dosing is based on the encapsidated vector genome. Quantitative polymerase chain reaction (qPCR is now the most common method to titer vector genomes (vg; however, significant inter- and intralaboratory variations have been documented using this technique. Here, RSMs and rAAV stocks were titered on the basis of an inverted terminal repeats (ITRs sequence-specific qPCR and we found an artificial increase in vg titers using a widely utilized approach. The PCR error was introduced by using single-cut linearized plasmid as the standard curve. This bias was eliminated using plasmid standards linearized just outside the ITR region on each end to facilitate the melting of the palindromic ITR sequences during PCR. This new “Free-ITR” qPCR delivers vg titers that are consistent with titers obtained with transgene-specific qPCR and could be used to normalize in-house product-specific AAV vector standards and controls to the rAAV RSMs. The free-ITR method, including well-characterized controls, will help to calibrate doses to compare preclinical and clinical data in the field.

  11. Practical utilization of recombinant AAV vector reference standards: focus on vector genomes titration by free ITR qPCR.

    Science.gov (United States)

    D'Costa, Susan; Blouin, Veronique; Broucque, Frederic; Penaud-Budloo, Magalie; François, Achille; Perez, Irene C; Le Bec, Christine; Moullier, Philippe; Snyder, Richard O; Ayuso, Eduard

    2016-01-01

    Clinical trials using recombinant adeno-associated virus (rAAV) vectors have demonstrated efficacy and a good safety profile. Although the field is advancing quickly, vector analytics and harmonization of dosage units are still a limitation for commercialization. AAV reference standard materials (RSMs) can help ensure product safety by controlling the consistency of assays used to characterize rAAV stocks. The most widely utilized unit of vector dosing is based on the encapsidated vector genome. Quantitative polymerase chain reaction (qPCR) is now the most common method to titer vector genomes (vg); however, significant inter- and intralaboratory variations have been documented using this technique. Here, RSMs and rAAV stocks were titered on the basis of an inverted terminal repeats (ITRs) sequence-specific qPCR and we found an artificial increase in vg titers using a widely utilized approach. The PCR error was introduced by using single-cut linearized plasmid as the standard curve. This bias was eliminated using plasmid standards linearized just outside the ITR region on each end to facilitate the melting of the palindromic ITR sequences during PCR. This new "Free-ITR" qPCR delivers vg titers that are consistent with titers obtained with transgene-specific qPCR and could be used to normalize in-house product-specific AAV vector standards and controls to the rAAV RSMs. The free-ITR method, including well-characterized controls, will help to calibrate doses to compare preclinical and clinical data in the field.

  12. Tramp ship routing and scheduling with integrated bunker optimization

    DEFF Research Database (Denmark)

    Vilhelmsen, Charlotte; Lusby, Richard Martin; Larsen, Jesper

    2014-01-01

    is referred to as bunker and bunker costs constitute a significant part of the daily operating costs. There can be great variations in bunker prices across bunker ports so it is important to carefully plan bunkering for each ship. As ships operate 24 hours a day, they must refuel during operations. Therefore...... and scheduling phase and present a mixed integer programming formulation for the integrated problem of optimally routing, scheduling and bunkering a tramp fleet. Aside from the integration of bunker, this model also extends standard tramp formulations by using load dependent costs, speed and bunker consumption...

  13. 46 CFR 164.023-3 - Specifications and standards incorporated by reference.

    Science.gov (United States)

    2010-10-01

    ... are: Federal Standards and Test Method Standards The following test methods in Federal Test Method Standard No. 191A, Textile Test Methods, July 20, 1978: (1) Method 4010, Length-Weight Relation; Thread..., Polyester Core: Cotton-, Rayon-, or Polyester-Covered, September 30, 1986—164.023-5. (7) MIL-T-43624A—Thread...

  14. Towards Automatic Testing of Reference Point Based Interactive Methods

    OpenAIRE

    Ojalehto, Vesa; Podkopaev, Dmitry; Miettinen, Kaisa

    2016-01-01

    In order to understand strengths and weaknesses of optimization algorithms, it is important to have access to different types of test problems, well defined performance indicators and analysis tools. Such tools are widely available for testing evolutionary multiobjective optimization algorithms. To our knowledge, there do not exist tools for analyzing the performance of interactive multiobjective optimization methods based on the reference point approach to communicating ...

  15. Optimal cloning of qubits given by an arbitrary axisymmetric distribution on the Bloch sphere

    International Nuclear Information System (INIS)

    Bartkiewicz, Karol; Miranowicz, Adam

    2010-01-01

    We find an optimal quantum cloning machine, which clones qubits of arbitrary symmetrical distribution around the Bloch vector with the highest fidelity. The process is referred to as phase-independent cloning in contrast to the standard phase-covariant cloning for which an input qubit state is a priori better known. We assume that the information about the input state is encoded in an arbitrary axisymmetric distribution (phase function) on the Bloch sphere of the cloned qubits. We find analytical expressions describing the optimal cloning transformation and fidelity of the clones. As an illustration, we analyze cloning of qubit state described by the von Mises-Fisher and Brosseau distributions. Moreover, we show that the optimal phase-independent cloning machine can be implemented by modifying the mirror phase-covariant cloning machine for which quantum circuits are known.

  16. A novel strategy with standardized reference extract qualification and single compound quantitative evaluation for quality control of Panax notoginseng used as a functional food.

    Science.gov (United States)

    Li, S P; Qiao, C F; Chen, Y W; Zhao, J; Cui, X M; Zhang, Q W; Liu, X M; Hu, D J

    2013-10-25

    Root of Panax notoginseng (Burk.) F.H. Chen (Sanqi in Chinese) is one of traditional Chinese medicines (TCMs) based functional food. Saponins are the major bioactive components. The shortage of reference compounds or chemical standards is one of the main bottlenecks for quality control of TCMs. A novel strategy, i.e. standardized reference extract based qualification and single calibrated components directly quantitative estimation of multiple analytes, was proposed to easily and effectively control the quality of natural functional foods such as Sanqi. The feasibility and credibility of this methodology were also assessed with a developed fast HPLC method. Five saponins, including ginsenoside Rg1, Re, Rb1, Rd and notoginsenoside R1 were rapidly separated using a conventional HPLC in 20 min. The quantification method was also compared with individual calibration curve method. The strategy is feasible and credible, which is easily and effectively adapted for improving the quality control of natural functional foods such as Sanqi. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. With Reference to Reference Genes: A Systematic Review of Endogenous Controls in Gene Expression Studies.

    Science.gov (United States)

    Chapman, Joanne R; Waldenström, Jonas

    2015-01-01

    The choice of reference genes that are stably expressed amongst treatment groups is a crucial step in real-time quantitative PCR gene expression studies. Recent guidelines have specified that a minimum of two validated reference genes should be used for normalisation. However, a quantitative review of the literature showed that the average number of reference genes used across all studies was 1.2. Thus, the vast majority of studies continue to use a single gene, with β-actin (ACTB) and/or glyceraldehyde 3-phosphate dehydrogenase (GAPDH) being commonly selected in studies of vertebrate gene expression. Few studies (15%) tested a panel of potential reference genes for stability of expression before using them to normalise data. Amongst studies specifically testing reference gene stability, few found ACTB or GAPDH to be optimal, whereby these genes were significantly less likely to be chosen when larger panels of potential reference genes were screened. Fewer reference genes were tested for stability in non-model organisms, presumably owing to a dearth of available primers in less well characterised species. Furthermore, the experimental conditions under which real-time quantitative PCR analyses were conducted had a large influence on the choice of reference genes, whereby different studies of rat brain tissue showed different reference genes to be the most stable. These results highlight the importance of validating the choice of normalising reference genes before conducting gene expression studies.

  18. A Novel Optimal Control Method for Impulsive-Correction Projectile Based on Particle Swarm Optimization

    Directory of Open Access Journals (Sweden)

    Ruisheng Sun

    2016-01-01

    Full Text Available This paper presents a new parametric optimization approach based on a modified particle swarm optimization (PSO to design a class of impulsive-correction projectiles with discrete, flexible-time interval, and finite-energy control. In terms of optimal control theory, the task is described as the formulation of minimum working number of impulses and minimum control error, which involves reference model linearization, boundary conditions, and discontinuous objective function. These result in difficulties in finding the global optimum solution by directly utilizing any other optimization approaches, for example, Hp-adaptive pseudospectral method. Consequently, PSO mechanism is employed for optimal setting of impulsive control by considering the time intervals between two neighboring lateral impulses as design variables, which makes the briefness of the optimization process. A modification on basic PSO algorithm is developed to improve the convergence speed of this optimization through linearly decreasing the inertial weight. In addition, a suboptimal control and guidance law based on PSO technique are put forward for the real-time consideration of the online design in practice. Finally, a simulation case coupled with a nonlinear flight dynamic model is applied to validate the modified PSO control algorithm. The results of comparative study illustrate that the proposed optimal control algorithm has a good performance in obtaining the optimal control efficiently and accurately and provides a reference approach to handling such impulsive-correction problem.

  19. Extension of an Object-Oriented Optimization Tool: User's Reference Manual

    Science.gov (United States)

    Pak, Chan-Gi; Truong, Samson S.

    2015-01-01

    The National Aeronautics and Space Administration Armstrong Flight Research Center has developed a cost-effective and flexible object-oriented optimization (O (sup 3)) tool that leverages existing tools and practices and allows easy integration and adoption of new state-of-the-art software. This object-oriented framework can integrate the analysis codes for multiple disciplines, as opposed to relying on one code to perform analysis for all disciplines. Optimization can thus take place within each discipline module, or in a loop between the O (sup 3) tool and the discipline modules, or both. Six different sample mathematical problems are presented to demonstrate the performance of the O (sup 3) tool. Instructions for preparing input data for the O (sup 3) tool are detailed in this user's manual.

  20. An open source, 3D printed preclinical MRI phantom for repeated measures of contrast agents and reference standards.

    Science.gov (United States)

    Cox, B L; Ludwig, K D; Adamson, E B; Eliceiri, K W; Fain, S B

    2018-03-01

    In medical imaging, clinicians, researchers and technicians have begun to use 3D printing to create specialized phantoms to replace commercial ones due to their customizable and iterative nature. Presented here is the design of a 3D printed open source, reusable magnetic resonance imaging (MRI) phantom, capable of flood-filling, with removable samples for measurements of contrast agent solutions and reference standards, and for use in evaluating acquisition techniques and image reconstruction performance. The phantom was designed using SolidWorks, a computer-aided design software package. The phantom consists of custom and off-the-shelf parts and incorporates an air hole and Luer Lock system to aid in flood filling, a marker for orientation of samples in the filled mode and bolt and tube holes for assembly. The cost of construction for all materials is under $90. All design files are open-source and available for download. To demonstrate utility, B 0 field mapping was performed using a series of gadolinium concentrations in both the unfilled and flood-filled mode. An excellent linear agreement (R 2 >0.998) was observed between measured relaxation rates (R 1 /R 2 ) and gadolinium concentration. The phantom provides a reliable setup to test data acquisition and reconstruction methods and verify physical alignment in alternative nuclei MRI techniques (e.g. carbon-13 and fluorine-19 MRI). A cost-effective, open-source MRI phantom design for repeated quantitative measurement of contrast agents and reference standards in preclinical research is presented. Specifically, the work is an example of how the emerging technology of 3D printing improves flexibility and access for custom phantom design.

  1. 40 CFR 90.7 - Reference materials.

    Science.gov (United States)

    2010-07-01

    .... ASTM D3231-89: Standard Test Method for Phosphorus in Gasoline Appendix A to subpart D, Table 3. ASTM D3606-92: Standard Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation... 770141, Optimization of a Flame Ionization Detector for Determination of Hydrocarbon in Diluted...

  2. Integer and combinatorial optimization

    CERN Document Server

    Nemhauser, George L

    1999-01-01

    Rave reviews for INTEGER AND COMBINATORIAL OPTIMIZATION ""This book provides an excellent introduction and survey of traditional fields of combinatorial optimization . . . It is indeed one of the best and most complete texts on combinatorial optimization . . . available. [And] with more than 700 entries, [it] has quite an exhaustive reference list.""-Optima ""A unifying approach to optimization problems is to formulate them like linear programming problems, while restricting some or all of the variables to the integers. This book is an encyclopedic resource for such f

  3. Local diagnostic reference levels, approaches and compare the values in the South Bohemia Region in view of radiation protection inspector

    International Nuclear Information System (INIS)

    Zemanova, E.

    2014-01-01

    This paper compares the value of local diagnostic reference levels(the LDRL)in health facilities of the South Bohemia Region. The work is motivated by questions of licensees, who would like to know their position in terms of the LDRL compared to other workplaces. Also by the activity of the inspector who can identify the problematic workplaces, where is necessary to increase attention to optimization, exposure, or justification. In connection with the ongoing internal audits in licensee workplaces the information about the status of the LDRL among others is current, motivating licensee to changes, optimization and verification of compliance with the recommendation of the National radiological standard of Ministry of Health (author)

  4. Website Optimization

    CERN Document Server

    King, Andrew

    2008-01-01

    Remember when an optimized website was one that merely didn't take all day to appear? Times have changed. Today, website optimization can spell the difference between enterprise success and failure, and it takes a lot more know-how to achieve success. This book is a comprehensive guide to the tips, techniques, secrets, standards, and methods of website optimization. From increasing site traffic to maximizing leads, from revving up responsiveness to increasing navigability, from prospect retention to closing more sales, the world of 21st century website optimization is explored, exemplified a

  5. REDEFINING ENSO EPISODES BASED ON CHANGED CLIMATE REFERENCES

    Institute of Scientific and Technical Information of China (English)

    LI Xiao-yan; ZHAI Pan-mao; REN Fu-min

    2005-01-01

    Through studying changes in ENSO indices relative to change of climate reference from 1961~1990 to 1971~2000, the study generated new standards to define ENSO episodes and their intensities. Then according to the new climate references and new index standards, ENSO episodes and their intensities for the period 1951 -2003 have been classified. Finally, an analysis has been performed comparing the new characteristics with the old ones for ENSO period, peak values and intensities.

  6. Supply-Chain Optimization Template

    Science.gov (United States)

    Quiett, William F.; Sealing, Scott L.

    2009-01-01

    The Supply-Chain Optimization Template (SCOT) is an instructional guide for identifying, evaluating, and optimizing (including re-engineering) aerospace- oriented supply chains. The SCOT was derived from the Supply Chain Council s Supply-Chain Operations Reference (SCC SCOR) Model, which is more generic and more oriented toward achieving a competitive advantage in business.

  7. Waste package reference conceptual designs for a repository in salt

    International Nuclear Information System (INIS)

    1986-02-01

    This report provides the reference conceptual waste package designs for the Office of Nuclear Waste Isolation to baseline these designs, thereby establishing the configuration and interface controls necessary, within the Civilian Radioactive Waste Management Program, formerly the National Waste Terminal Storage Program, to proceed in an orderly manner with preliminary design. Included are designs for the current reference defense high-level waste form from the Savannah River Plant, an optimized commercial high-level waste form, and spent fuel which has been disassembled and compacted into a circular bundle containing either 12 pressurized-water reactor or 30 boiling-water reactor assemblies. For compacted spent fuel, it appears economically attractive to standardize the waste package diameter for all fuel types. The reference waste packages consist of the containerized waste form, a low carbon steel overpack, and, after emplacement, a cover of salt. The overpack is a hollow cylinder with a flat head welded to each end. Its design thickness is the sum of the structural thickness required to resist the 15.4-MPa lithostatic pressure plus the corrosion allowance necessary to assure the required structural thickness will exist through the 1000-year containment period. Based on available data and completed analyses, the reference concepts described in this report satisfy all requirements of the US Department of Energy and the US Nuclear Regulatory Commission with reasonable assurance. In addition, sufficient design maturity exists to form a basis for preliminary design; these concepts can be brought under configuration control to serve as reference package designs. Development programs are identified that will be required to support these designs during the licensing process. 19 refs., 37 figs., 31 tabs

  8. HEURISTIC APPROACHES FOR PORTFOLIO OPTIMIZATION

    OpenAIRE

    Manfred Gilli, Evis Kellezi

    2000-01-01

    The paper first compares the use of optimization heuristics to the classical optimization techniques for the selection of optimal portfolios. Second, the heuristic approach is applied to problems other than those in the standard mean-variance framework where the classical optimization fails.

  9. Standard setting: comparison of two methods.

    Science.gov (United States)

    George, Sanju; Haque, M Sayeed; Oyebode, Femi

    2006-09-14

    The outcome of assessments is determined by the standard-setting method used. There is a wide range of standard-setting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. The norm-reference method of standard-setting (mean minus 1 SD) was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ). Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart). We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. The pass rate with the norm-reference method was 85% (66/78) and that by the Angoff method was 100% (78 out of 78). The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% - 87%). The modified Angoff method had an inter-rater reliability of 0.81-0.82 and a test-retest reliability of 0.59-0.74. There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.

  10. Technical Note: Modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies

    International Nuclear Information System (INIS)

    Konstantinidis, Anastasios C.; Olivo, Alessandro; Speller, Robert D.

    2011-01-01

    Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The ''gold standard'' method used for the reduction of the FPN (i.e., the different gain between pixels) in linear x-ray detectors is based on normalization with an average reference flat-field. However, the noise in the corrected image depends on the number of flat frames used for the average flat image. The aim of this study is to modify the standard gain correction algorithm to make it independent on the used reference flat frames. Methods: Many publications suggest the use of 10-16 reference flat frames, while other studies use higher numbers (e.g., 48 frames) to reduce the propagated noise from the average flat image. This study quantifies experimentally the effect of the number of used reference flat frames on the NPS and DQE values and appropriately modifies the gain correction algorithm to compensate for this effect. Results: It is shown that using the suggested gain correction algorithm a minimum number of reference flat frames (i.e., down to one frame) can be used to eliminate the FPN from the raw flat image. This saves computer memory and time during the x-ray performance evaluation. Conclusions: The authors show that the method presented in the study (a) leads to the maximum DQE value that one would have by using the conventional method and very large number of frames and (b) has been compared to an independent gain correction method based on the subtraction of flat-field images, leading to identical DQE values. They believe this provides robust validation of the proposed method.

  11. Optimal trajectories of aircraft and spacecraft

    Science.gov (United States)

    Miele, A.

    1990-01-01

    Work done on algorithms for the numerical solutions of optimal control problems and their application to the computation of optimal flight trajectories of aircraft and spacecraft is summarized. General considerations on calculus of variations, optimal control, numerical algorithms, and applications of these algorithms to real-world problems are presented. The sequential gradient-restoration algorithm (SGRA) is examined for the numerical solution of optimal control problems of the Bolza type. Both the primal formulation and the dual formulation are discussed. Aircraft trajectories, in particular, the application of the dual sequential gradient-restoration algorithm (DSGRA) to the determination of optimal flight trajectories in the presence of windshear are described. Both take-off trajectories and abort landing trajectories are discussed. Take-off trajectories are optimized by minimizing the peak deviation of the absolute path inclination from a reference value. Abort landing trajectories are optimized by minimizing the peak drop of altitude from a reference value. Abort landing trajectories are optimized by minimizing the peak drop of altitude from a reference value. The survival capability of an aircraft in a severe windshear is discussed, and the optimal trajectories are found to be superior to both constant pitch trajectories and maximum angle of attack trajectories. Spacecraft trajectories, in particular, the application of the primal sequential gradient-restoration algorithm (PSGRA) to the determination of optimal flight trajectories for aeroassisted orbital transfer are examined. Both the coplanar case and the noncoplanar case are discussed within the frame of three problems: minimization of the total characteristic velocity; minimization of the time integral of the square of the path inclination; and minimization of the peak heating rate. The solution of the second problem is called nearly-grazing solution, and its merits are pointed out as a useful

  12. Comparison of different standards used in radioimmunoassay for atrial natriuretic factor (ANF)

    DEFF Research Database (Denmark)

    Rasmussen, Peter Have; Nielsen, M. Damkjær; Giese, J.

    1991-01-01

    , estimates of the ANF content in human plasma samples with different standard preparations as the reference showed a considerable variability. With the international standard as the gold reference (plasma ANF concentration 100%) the apparent plasma ANF concentrations measured with the other reference......Six different standards for determination of atrial natriuretic factor (ANF) in human plasma samples have been compared using our radio-immunoassay for ANF: International standard 85/669, National Biological Standard Boards, UK; Bachem standard, Torrance, USA; Bachem standard, Bubendorf......, Switzerland; Bissendorf standard, Wedemark, Germany; Peninsula standard, Belmont, USA; UCB-Bioproducts standard, Brussels, Belgium, Standard curves obtained with different preparations were in parallel but showed considerable quantitative differences. Standard curves referring to the Bissendorf standard...

  13. 78 FR 37696 - Federal Acquisition Regulation; Updated Postretirement Benefit (PRB) References

    Science.gov (United States)

    2013-06-21

    ... that were deleted in the Financial Accounting Standards Board's (FASB's) Accounting Standards Codification (ASC) of Generally Accepted Accounting Principles (GAAP). The references no longer exist in the..., 2012, to replace the obsolete references to paragraphs 110, 112, and 113 of Financial Accounting...

  14. Weather Test Reference Year of Greenland

    DEFF Research Database (Denmark)

    Kragh, Jesper; Pedersen, Frank; Svendsen, Svend

    2005-01-01

    the construction of two test reference years of Greenland used in the work of establishing new energy frame for the coming building code of Greenland. The first test reference year is constructed using measurements of climatic parameters from the town Nuuk located in the southwestern part of Greenland. The second...... test reference year is constructed using measurements from the town Uummannaq located in the north part of Greenland on the west coast. The construction of the test reference years fulfills the procedures described in the standard EN ISO 15927-4 using the following main weather parameters: Dry bulb...... temperature, global radiation, relative humidity and mean wind speed. To construct the test reference years a program called REFYEAR was developed in MatLab. REFYEAR automatically constructs the test reference year using an input file containing the climatic measurements. The two constructed test reference...

  15. HTML & XHTML Pocket Reference

    CERN Document Server

    Robbins, Jennifer

    2010-01-01

    After years of using spacer GIFs, layers of nested tables, and other improvised solutions for building your web sites, getting used to the more stringent standards-compliant design can be intimidating. HTML and XHTML Pocket Reference is the perfect little book when you need answers immediately. Jennifer Niederst-Robbins, author Web Design in a Nutshell, has revised and updated the fourth edition of this pocket guide by taking the top 20% of vital reference information from her Nutshell book, augmenting it judiciously, cross-referencing everything, and organizing it according to the most com

  16. Dynamic Optimization of UV Flash Processes

    DEFF Research Database (Denmark)

    Ritschel, Tobias Kasper Skovborg; Capolei, Andrea; Jørgensen, John Bagterp

    2017-01-01

    UV ash processes, also referred to as isoenergetic-isochoric ash processes, occur for dynamic simulation and optimization of vapor-liquid equilibrium processes. Dynamic optimization and nonlinear model predictive control of distillation columns, certain two-phase ow problems, as well as oil reser...... that the optimization solver, the compiler, and high-performance linear algebra software are all important for e_cient dynamic optimization of UV ash processes....

  17. Some considerations about standardization

    Energy Technology Data Exchange (ETDEWEB)

    Dewez, Ph L; Fanjas, Y R [C.E.R.C.A., Romans (France)

    1985-07-01

    Complete standardization of research reactor fuel is not possible. However the transition from HEU to LEU should be an opportunity for a double effort towards standardization and optimization in order to reduce cost. (author)

  18. Some considerations about standardization

    International Nuclear Information System (INIS)

    Dewez, Ph.L.; Fanjas, Y.R.

    1985-01-01

    Complete standardization of research reactor fuel is not possible. However the transition from HEU to LEU should be an opportunity for a double effort towards standardization and optimization in order to reduce cost. (author)

  19. Estimation of individual reference intervals in small sample sizes

    DEFF Research Database (Denmark)

    Hansen, Ase Marie; Garde, Anne Helene; Eller, Nanna Hurwitz

    2007-01-01

    In occupational health studies, the study groups most often comprise healthy subjects performing their work. Sampling is often planned in the most practical way, e.g., sampling of blood in the morning at the work site just after the work starts. Optimal use of reference intervals requires...... from various variables such as gender, age, BMI, alcohol, smoking, and menopause. The reference intervals were compared to reference intervals calculated using IFCC recommendations. Where comparable, the IFCC calculated reference intervals had a wider range compared to the variance component models...

  20. The Characteristics of the Exergy Reference Environment and Its Implications for Sustainability-Based Decision-Making

    Directory of Open Access Journals (Sweden)

    Stephen Murphy

    2012-07-01

    Full Text Available In the energy realm there is a pressing need to make decisions in a complex world characterized by biophysical limits. Exergy has been promoted as a preferred means of characterizing the impacts of resource consumption and waste production for the purpose of improving decision-making. This paper provides a unique and critical analysis of universal and comprehensive formulations of the chemical exergy reference environment, for the purpose of better understanding how exergy can inform decision-making. Four related insights emerged from the analysis, notably: (1 standard and universal chemical exergy reference environments necessarily encounter internal inconsistencies and even contradictions in their very formulations; (2 these inconsistencies are a result of incompatibility between the exergy reference environment and natural environment, and the desire to model the exergy reference environment after the natural environment so as to maintain analytical relevance; (3 the topics for which exergy is most appropriate as an analytical tool are not well served by comprehensive reference environments, and (4 the inconsistencies point to a need for deeper reflection of whether it is appropriate to adopt a thermodynamic frame of analysis for situations whose relevant characteristics are non-thermodynamic (e.g., to characterize scarcity. The use of comprehensive reference environments may lead to incorrect recommendations and ultimately reduce its appeal for informing decision-making. Exergy may better inform decision-making by returning to process dependent reference states that model specific processes and situations for the purpose of engineering optimization.

  1. Dose evaluation and establishment of reference levels in activity for nuclear medicine; Avaliação de dose e estabelecimento de níveis de referência em atividade para a medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Julio Cesar de Souza

    2017-07-01

    The International Commission on Radiation Protection (ICRP) has emphasized the importance of accurately determining the mean dose levels, or administered activity, received by the patients for each medical procedure that uses ionizing radiation. However, the number of bibliographic references addressing the need to know and optimize these levels is insufficient, or rather limited, which may lead to non-standardizes techniques, a lack of exposures control, and also the increase of associated radiological risks of these procedures. In this context, a software in Visual Basic® of Microsoft© language was developed whose function is to elaborate a method of obtaining the Reference Levels in Activity (RLA) for nuclear medicine patients by determining the third quartile of the examinations carried out. The program also allows obtaining absorbed dose values in critical organs based on patient specificities as age, sex and Body Mass Index (BMI) in order to evaluate the risk involved in each procedure. The main nuclear medicine diagnostic procedures were evaluated through the database of two public hospitals and a private clinic, obtaining the NRAs of each facility, where the software was validated by comparison with the traditionally accepted calculation methods. Due to the results obtained in each installation, in addition to NRA determination, gaps in treatment capacities and unjustified dose variations for the same procedure were identified, indicating the need for optimization. Thus, the developed program is able to provide the estimated values of effective and absorbed doses involved in each procedure, for each patient, providing reference values for nuclear medicine field, not available in the national scenario so far. (author)

  2. A comparative study of standard vs. high definition colonoscopy for adenoma and hyperplastic polyp detection with optimized withdrawal technique.

    Science.gov (United States)

    East, J E; Stavrindis, M; Thomas-Gibson, S; Guenther, T; Tekkis, P P; Saunders, B P

    2008-09-15

    Colonoscopy has a known miss rate for polyps and adenomas. High definition (HD) colonoscopes may allow detection of subtle mucosal change, potentially aiding detection of adenomas and hyperplastic polyps. To compare detection rates between HD and standard definition (SD) colonoscopy. Prospective, cohort study with optimized withdrawal technique (withdrawal time >6 min, antispasmodic, position changes, re-examining flexures and folds). One hundred and thirty patients attending for routine colonoscopy were examined with either SD (n = 72) or HD (n = 58) colonoscopes. Groups were well matched. Sixty per cent of patients had at least one adenoma detected with SD vs. 71% with HD, P = 0.20, relative risk (benefit) 1.32 (95% CI 0.85-2.04). Eighty-eight adenomas (mean +/- standard deviation 1.2 +/- 1.4) were detected using SD vs. 93 (1.6 +/- 1.5) with HD, P = 0.12; however more nonflat, diminutive (9 mm) hyperplastic polyps was 7% (0.09 +/- 0.36). High definition did not lead to a significant increase in adenoma or hyperplastic polyp detection, but may help where comprehensive lesion detection is paramount. High detection rates appear possible with either SD or HD, when using an optimized withdrawal technique.

  3. Revision of the SNPforID 34-plex forensic ancestry test: Assay enhancements, standard reference sample genotypes and extended population studies.

    Science.gov (United States)

    Fondevila, M; Phillips, C; Santos, C; Freire Aradas, A; Vallone, P M; Butler, J M; Lareu, M V; Carracedo, A

    2013-01-01

    A revision of an established 34 SNP forensic ancestry test has been made by swapping the under-performing rs727811 component SNP with the highly informative rs3827760 that shows a near-fixed East Asian specific allele. We collated SNP variability data for the revised SNP set in 66 reference populations from 1000 Genomes and HGDP-CEPH panels and used this as reference data to analyse four U.S. populations showing a range of admixture patterns. The U.S. Hispanics sample in particular displayed heterogeneous values of co-ancestry between European, Native American and African contributors, likely to reflect in part, the way this disparate group is defined using cultural as well as population genetic parameters. The genotyping of over 700 U.S. population samples also provided the opportunity to thoroughly gauge peak mobility variation and peak height ratios observed from routine use of the single base extension chemistry of the 34-plex test. Finally, the genotyping of the widely used DNA profiling Standard Reference Material samples plus other control DNAs completes the audit of the 34-plex assay to allow forensic practitioners to apply this test more readily in their own laboratories. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Determination of technetium-99 in environmental standard reference materials by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Technetium-99 is an artificial radionuclide which is produced in the fission of 235 U or 239 Pu with a relatively high fission yield of ca. 6%. Because of its long half-life of 2.1 x 10 5 y, 99 Tc has been accumulating in the environment, and thus, is considered to present a potential risk for humans. It is important for dose assessments to identify the behavior of the nuclide in the environment. Analysis data of global fallout 99 Tc in environmental samples would give useful information for predicting the nuclide's behavior; however, due to its low concentration and analytical difficulties, not much data are available. Besides, no environmental standard reference material (SRM) for 99 Tc is available. If we could get suitable SRMs for 99 Tc analysis, it would be easier to determine the concentration of 99 Tc in environmental samples. The purpose of this study was to investigate the possibility of several SRMs to be used as references for low-level 99 Tc. For this, ICP-MS was used for 99 Tc determination. In recent years, ICP-MS has been used for 99 Tc measurements instead of radioactivity counting methods. The samples used were as follows: A) IAEA-373 (a grass sample collected on grassland near Chernobyl Nuclear Power Reactor, Ukraine), B) IAEA-375 (a soil sample collected on a field near Chernobyl Nuclear Power Reactor, Russia), C) IAEA-135 (a sea sediment sample affected by Sellafield, UK), D) five seaweed samples of which the concentration levels are different from each other (collected around the coast near Sellafield, UK). Throughout the chemical separation, 95m Tc was used as a yield monitor. The sample was incinerated for at least 2 h at 450degC. After 99 Tc extraction from the sample at 90degC for 3 h with 4M HNO 3 , the sample was filtered and the residue on the filter was washed with deionized water. The solution was diluted to ca. 0.1M HNO 3 then passed through TEVA resin column (EIChroM Industries, Inc.) to extract Tc onto the resin. Then Tc was

  5. Standard setting: Comparison of two methods

    Directory of Open Access Journals (Sweden)

    Oyebode Femi

    2006-09-01

    Full Text Available Abstract Background The outcome of assessments is determined by the standard-setting method used. There is a wide range of standard – setting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. Methods The norm – reference method of standard -setting (mean minus 1 SD was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ. Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart. We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. Results The pass rate with the norm-reference method was 85% (66/78 and that by the Angoff method was 100% (78 out of 78. The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% – 87%. The modified Angoff method had an inter-rater reliability of 0.81 – 0.82 and a test-retest reliability of 0.59–0.74. Conclusion There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.

  6. Evaluation of new geological reference materials for uranium-series measurements: Chinese Geological Standard Glasses (CGSG) and macusanite obsidian.

    Science.gov (United States)

    Denton, J S; Murrell, M T; Goldstein, S J; Nunn, A J; Amato, R S; Hinrichs, K A

    2013-10-15

    Recent advances in high-resolution, rapid, in situ microanalytical techniques present numerous opportunities for the analytical community, provided accurately characterized reference materials are available. Here, we present multicollector thermal ionization mass spectrometry (MC-TIMS) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) uranium and thorium concentration and isotopic data obtained by isotope dilution for a suite of newly available Chinese Geological Standard Glasses (CGSG) designed for microanalysis. These glasses exhibit a range of compositions including basalt, syenite, andesite, and a soil. Uranium concentrations for these glasses range from ∼2 to 14 μg g(-1), Th/U weight ratios range from ∼4 to 6, (234)U/(238)U activity ratios range from 0.93 to 1.02, and (230)Th/(238)U activity ratios range from 0.98 to 1.12. Uranium and thorium concentration and isotopic data are also presented for a rhyolitic obsidian from Macusani, SE Peru (macusanite). This glass can also be used as a rhyolitic reference material, has a very low Th/U weight ratio (around 0.077), and is approximately in (238)U-(234)U-(230)Th secular equilibrium. The U-Th concentration data agree with but are significantly more precise than those previously measured. U-Th concentration and isotopic data agree within estimated errors for the two measurement techniques, providing validation of the two methods. The large (238)U-(234)U-(230)Th disequilibria for some of the glasses, along with the wide range in their chemical compositions and Th/U ratios should provide useful reference points for the U-series analytical community.

  7. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the VSL and the BIPM

    DEFF Research Database (Denmark)

    Alvarez, J.T.; De Pooter, J.A.; Andersen, Claus E.

    2014-01-01

    An indirect comparison of the standards for reference air kerma rate for 192Ir high dose rate brachytherapy sources of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the VSL in November 2009. The comparison resu...

  8. Reference standard of penile size and prevalence of buried penis in Japanese newborn male infants.

    Science.gov (United States)

    Matsuo, Nobutake; Ishii, Tomohiro; Takayama, John I; Miwa, Masayuki; Hasegawa, Tomonobu

    2014-01-01

    The present study set forth the reference values for penile size and determined the prevalence of buried penis in Japanese full-term newborns. The stretched penile length was measured and the presence of buried penis was assessed at 1-7 days of age in 547 Japanese full-term newborn infants born between 2008 and 2012 in Tokyo. The stretched penile lengths were compared at 1-12 hours and 1-7 days of age in 63 infants and by two observers in 73 infants to estimate postnatal changes and interobserver variation, respectively. The mean stretched penile length was 3.06 cm (SD, 0.26; 95% confidence interval [CI], 3.04-3.08) and the mean ratio of penile length to body length was 6.24 × 100(-1) (SD, 0.55 × 100(-1)), both of which were significantly smaller than those in Caucasian newborn infants. Buried penis was identified in 20 of 547 infants (3.7%; 95% CI, 2.1-5.2%). The first measurements of penile length at 1-12 hours were significantly smaller than the next measurements at 1-7 days (95% CI of the difference, 0.22-0.34). The 95% CI for the limits of agreement in the penile lengths measured by the two observers was -0.58 to -0.40 for the lower limit and 0.33 to 0.51 for the upper limit. These findings indicate that the penile length should be assessed after 24 hours of age by the reference standard of the same ethnicity for identifying micropenis and that buried penis is not uncommon in Japanese full-term newborns.

  9. Regulation of Dynamical Systems to Optimal Solutions of Semidefinite Programs: Algorithms and Applications to AC Optimal Power Flow

    Energy Technology Data Exchange (ETDEWEB)

    Dall' Anese, Emiliano; Dhople, Sairaj V.; Giannakis, Georgios B.

    2015-07-01

    This paper considers a collection of networked nonlinear dynamical systems, and addresses the synthesis of feedback controllers that seek optimal operating points corresponding to the solution of pertinent network-wide optimization problems. Particular emphasis is placed on the solution of semidefinite programs (SDPs). The design of the feedback controller is grounded on a dual e-subgradient approach, with the dual iterates utilized to dynamically update the dynamical-system reference signals. Global convergence is guaranteed for diminishing stepsize rules, even when the reference inputs are updated at a faster rate than the dynamical-system settling time. The application of the proposed framework to the control of power-electronic inverters in AC distribution systems is discussed. The objective is to bridge the time-scale separation between real-time inverter control and network-wide optimization. Optimization objectives assume the form of SDP relaxations of prototypical AC optimal power flow problems.

  10. Topology optimization of microwave waveguide filters

    DEFF Research Database (Denmark)

    Aage, Niels; Johansen, Villads Egede

    2017-01-01

    We present a density based topology optimization approach for the design of metallic microwave insert filters. A two-phase optimization procedure is proposed in which we, starting from a uniform design, first optimize to obtain a set of spectral varying resonators followed by a band gap...... optimization for the desired filter characteristics. This is illustrated through numerical experiments and comparison to a standard band pass filter design. It is seen that the carefully optimized topologies can sharpen the filter characteristics and improve performance. Furthermore, the obtained designs share...... little resemblance to standard filter layouts and hence the proposed design method offers a new design tool in microwave engineering....

  11. Ant colony search algorithm for optimal reactive power optimization

    Directory of Open Access Journals (Sweden)

    Lenin K.

    2006-01-01

    Full Text Available The paper presents an (ACSA Ant colony search Algorithm for Optimal Reactive Power Optimization and voltage control of power systems. ACSA is a new co-operative agents’ approach, which is inspired by the observation of the behavior of real ant colonies on the topic of ant trial formation and foraging methods. Hence, in the ACSA a set of co-operative agents called "Ants" co-operates to find good solution for Reactive Power Optimization problem. The ACSA is applied for optimal reactive power optimization is evaluated on standard IEEE, 30, 57, 191 (practical test bus system. The proposed approach is tested and compared to genetic algorithm (GA, Adaptive Genetic Algorithm (AGA.

  12. Reference materials for microanalytical nuclear techniques

    Energy Technology Data Exchange (ETDEWEB)

    Injuk, Jasna; Grieken, Rene van [Department of Chemistry, Micro and Trace Analysis Centre, University of Antwerp, Wilrijk-Antwerp (Belgium)

    1994-07-01

    This paper discusses some issues concerning reference materials required for microanalysis including physical and chemical properties of the sample matrix and homogeneity of the chemical composition. It gives some examples of the mst common standards used. Further the paper gives background information about the Micro- and Trace Analysis Center of the University of Antwerp, Belgium and discusses recent results of the Center in microanalysis of reference materials.

  13. Space-Time Reference Systems

    CERN Document Server

    Soffel, Michael

    2013-01-01

    The high accuracy of modern astronomical spatial-temporal reference systems has made them considerably complex. This book offers a comprehensive overview of such systems. It begins with a discussion of ‘The Problem of Time’, including recent developments in the art of clock making (e.g., optical clocks) and various time scales. The authors address  the definitions and realization of spatial coordinates by reference to remote celestial objects such as quasars. After an extensive treatment of classical equinox-based coordinates, new paradigms for setting up a celestial reference system are introduced that no longer refer to the translational and rotational motion of the Earth. The role of relativity in the definition and realization of such systems is clarified. The topics presented in this book are complemented by exercises (with solutions). The authors offer a series of files, written in Maple, a standard computer algebra system, to help readers get a feel for the various models and orders of magnitude. ...

  14. Comparison of Centers for Disease Control and Prevention and World Health Organization references/standards for height in contemporary Australian children: analyses of the Raine Study and Australian National Children's Nutrition and Physical Activity cohorts.

    Science.gov (United States)

    Hughes, Ian; Harris, Mark; Cotterill, Andrew; Garnett, Sarah; Bannink, Ellen; Pennell, Craig; Sly, Peter; Leong, Gary M; Cowell, Chris; Ambler, Geoff; Werther, George; Hofman, Paul; Cutfield, Wayne; Choong, Catherine S

    2014-11-01

    (i) To compare the Centers for Disease Control and Prevention (CDC) reference and World Health Organization (WHO) standard/reference for height, particularly with respect to short stature and eligibility for growth hormone (GH) treatment by applying them to contemporary Australian children; (ii) To examine the implications for identifying short stature and eligibility for GH treatment. Children from the longitudinal Raine Study were serially measured for height from 1991 to 2005 (2-15-year-old girls (660) and boys (702) from Western Australia). In the cross-sectional Australian National Children's Nutrition and Physical Activity survey (2-16-year-old boys (2415) and girls (2379) from all states), height was measured in 2007. Heights were converted to standard deviation scores (SDSs) based on CDC and WHO. Means and standard deviations of height-SDS varied between CDC and WHO definitions and with age and gender within each definition. However, both identified similar frequencies of short stature (standard/reference for height. © 2014 The Authors. Journal of Paediatrics and Child Health © 2014 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  15. Fault estimation - A standard problem approach

    DEFF Research Database (Denmark)

    Stoustrup, J.; Niemann, Hans Henrik

    2002-01-01

    This paper presents a range of optimization based approaches to fault diagnosis. A variety of fault diagnosis problems are reformulated in the so-called standard problem set-up introduced in the literature on robust control. Once the standard problem formulations are given, the fault diagnosis...... problems can be solved by standard optimization techniques. The proposed methods include (1) fault diagnosis (fault estimation, (FE)) for systems with model uncertainties; FE for systems with parametric faults, and FE for a class of nonlinear systems. Copyright...

  16. Optimal Provision of Public Goods

    DEFF Research Database (Denmark)

    Kreiner, Claus Thustrup; Verdelin, Nicolaj

    2009-01-01

    There currently exist two competing approaches in the literature on the optimal provision of public goods. The standard approach highlights the importance of distortionary taxation and distributional concerns. The new approach neutralizes distributional concerns by adjusting the non-linear income...... for the optimal level of a public good without imposing strong assumptions on preferences. This formula shows that distortionary taxation may have a role to play as in the standard approach. However, the main determinants of optimal provision are completely different and the traditional formula with its emphasis...

  17. Optimization of source pencil deployment based on plant growth simulation algorithm

    International Nuclear Information System (INIS)

    Yang Lei; Liu Yibao; Liu Yujuan

    2009-01-01

    A plant growth simulation algorithm was proposed for optimizing source pencil deployment for a 60 Co irradiator. A method used to evaluate the calculation results was presented with the objective function defined by relative standard deviation of the exposure rate at the reference points, and the method to transform two kinds of control variables, i.e., position coordinates x j and y j of source pencils in the source plaque, into proper integer variables was also analyzed and solved. The results show that the plant growth simulation algorithm, which possesses both random and directional search mechanism, has good global search ability and can be used conveniently. The results are affected a little by initial conditions, and improve the uniformity in the irradiation fields. It creates a dependable field for the optimization of source bars arrangement at irradiation facility. (authors)

  18. Reference values for electrooculography

    International Nuclear Information System (INIS)

    Barrientos Castanno, Alberto; Herrera Mora, Maritza; Garcia Baez, Obel

    2012-01-01

    Obtain electrooculographic reference values based on the patterns set by the Standardization Committee of the International Society for Clinical Electrophysiology of Vision (ISCEV). the lowest amplitude values of the potential ranged between 388 and 882 μv in the dark phase. The light peak was obtained between 9 and 10 minutes, and during this phase the potential reached an amplitude ranging between 808 and 1 963 μv. This amplitude variability may be related to the fact that the test was conducted without pupillary mydriasis. The reference value obtained for Arden index was 1,55 to 2,87

  19. Sequential stochastic optimization

    CERN Document Server

    Cairoli, Renzo

    1996-01-01

    Sequential Stochastic Optimization provides mathematicians and applied researchers with a well-developed framework in which stochastic optimization problems can be formulated and solved. Offering much material that is either new or has never before appeared in book form, it lucidly presents a unified theory of optimal stopping and optimal sequential control of stochastic processes. This book has been carefully organized so that little prior knowledge of the subject is assumed; its only prerequisites are a standard graduate course in probability theory and some familiarity with discrete-paramet

  20. Global Reference Tables for Production Systems

    Data.gov (United States)

    Social Security Administration — This database is a collection of reference tables that store common information used throughout SSA. These tables standardized code structures and code usage of SSA...

  1. ANS shielding standards for light-water reactors

    International Nuclear Information System (INIS)

    Trubey, D.K.

    1982-01-01

    The purpose of the American Nuclear Society Standards Subcommittee, ANS-6, Radiation Protection and Shielding, is to develop standards for radiation protection and shield design, to provide shielding information to other standards-writing groups, and to develop standard reference shielding data and test problems. A total of seven published ANS-6 standards are now current. Additional projects of the subcommittee, now composed of nine working groups, include: standard reference data for multigroup cross sections, gamma-ray absorption coefficients and buildup factors, additional benchwork problems for shielding problems and energy spectrum unfolding, power plant zoning design for normal and accident conditions, process radiation monitors, and design for postaccident radiological conditions

  2. Automated Spatial Brain Normalization and Hindbrain White Matter Reference Tissue Give Improved [(18)F]-Florbetaben PET Quantitation in Alzheimer's Model Mice.

    Science.gov (United States)

    Overhoff, Felix; Brendel, Matthias; Jaworska, Anna; Korzhova, Viktoria; Delker, Andreas; Probst, Federico; Focke, Carola; Gildehaus, Franz-Josef; Carlsen, Janette; Baumann, Karlheinz; Haass, Christian; Bartenstein, Peter; Herms, Jochen; Rominger, Axel

    2016-01-01

    Preclinical PET studies of β-amyloid (Aβ) accumulation are of growing importance, but comparisons between research sites require standardized and optimized methods for quantitation. Therefore, we aimed to evaluate systematically the (1) impact of an automated algorithm for spatial brain normalization, and (2) intensity scaling methods of different reference regions for Aβ-PET in a large dataset of transgenic mice. PS2APP mice in a 6 week longitudinal setting (N = 37) and another set of PS2APP mice at a histologically assessed narrow range of Aβ burden (N = 40) were investigated by [(18)F]-florbetaben PET. Manual spatial normalization by three readers at different training levels was performed prior to application of an automated brain spatial normalization and inter-reader agreement was assessed by Fleiss Kappa (κ). For this method the impact of templates at different pathology stages was investigated. Four different reference regions on brain uptake normalization were used to calculate frontal cortical standardized uptake value ratios (SUVRCTX∕REF), relative to raw SUVCTX. Results were compared on the basis of longitudinal stability (Cohen's d), and in reference to gold standard histopathological quantitation (Pearson's R). Application of an automated brain spatial normalization resulted in nearly perfect agreement (all κ≥0.99) between different readers, with constant or improved correlation with histology. Templates based on inappropriate pathology stage resulted in up to 2.9% systematic bias for SUVRCTX∕REF. All SUVRCTX∕REF methods performed better than SUVCTX both with regard to longitudinal stability (d≥1.21 vs. d = 0.23) and histological gold standard agreement (R≥0.66 vs. R≥0.31). Voxel-wise analysis suggested a physiologically implausible longitudinal decrease by global mean scaling. The hindbrain white matter reference (R mean = 0.75) was slightly superior to the brainstem (R mean = 0.74) and the cerebellum (R mean = 0.73). Automated

  3. Pulmonary vessel segmentation utilizing curved planar reformation and optimal path finding (CROP) in computed tomographic pulmonary angiography (CTPA) for CAD applications

    Science.gov (United States)

    Zhou, Chuan; Chan, Heang-Ping; Kuriakose, Jean W.; Chughtai, Aamer; Wei, Jun; Hadjiiski, Lubomir M.; Guo, Yanhui; Patel, Smita; Kazerooni, Ella A.

    2012-03-01

    Vessel segmentation is a fundamental step in an automated pulmonary embolism (PE) detection system. The purpose of this study is to improve the segmentation scheme for pulmonary vessels affected by PE and other lung diseases. We have developed a multiscale hierarchical vessel enhancement and segmentation (MHES) method for pulmonary vessel tree extraction based on the analysis of eigenvalues of Hessian matrices. However, it is difficult to segment the pulmonary vessels accurately under suboptimal conditions, such as vessels occluded by PEs, surrounded by lymphoid tissues or lung diseases, and crossing with other vessels. In this study, we developed a new vessel refinement method utilizing curved planar reformation (CPR) technique combined with optimal path finding method (MHES-CROP). The MHES segmented vessels straightened in the CPR volume was refined using adaptive gray level thresholding where the local threshold was obtained from least-square estimation of a spline curve fitted to the gray levels of the vessel along the straightened volume. An optimal path finding method based on Dijkstra's algorithm was finally used to trace the correct path for the vessel of interest. Two and eight CTPA scans were randomly selected as training and test data sets, respectively. Forty volumes of interest (VOIs) containing "representative" vessels were manually segmented by a radiologist experienced in CTPA interpretation and used as reference standard. The results show that, for the 32 test VOIs, the average percentage volume error relative to the reference standard was improved from 32.9+/-10.2% using the MHES method to 9.9+/-7.9% using the MHES-CROP method. The accuracy of vessel segmentation was improved significantly (pvolume between the automated segmentation and the reference standard was improved from 0.919 to 0.988. Quantitative comparison of the MHES method and the MHES-CROP method with the reference standard was also evaluated by the Bland-Altman plot. This preliminary

  4. The Clinical Utility of ASRS-v1.1 for Identifying ADHD in Alcoholics Using PRISM as the Reference Standard.

    Science.gov (United States)

    Reyes, Maria M; Schneekloth, Terry D; Hitschfeld, Mario J; Geske, Jennifer R; Atkinson, David L; Karpyak, Victor M

    2016-05-02

    The objective was to assess the clinical utility of the Adult ADHD Self-Report Scale (ASRS-v1.1) in identifying ADHD in alcoholics using the Psychiatric Research Interview for Substance and Mental Disorders (PRISM) as the diagnostic "gold standard." We performed a secondary analysis of data from 379 treatment-seeking alcoholics who completed the ASRS-v1.1 and the ADHD module of the PRISM. Data analysis included descriptive statistics. The prevalence of ADHD was 7.7% (95% CI = [5.4, 10.8]). The positive predictive value (PPV) of the ASRS-v1.1 was 18.1% (95% CI = [12.4, 25.7]) and the negative predictive value (NPV) was 97.6% (95% CI = [94.9, 98.9]). The ASRS-v1.1 demonstrated a sensitivity of 79.3% (95% CI = [61.6, 90.2]) and a specificity of 70.3% (95% CI = [65.3, 74.8]). The ASRS-v1.1 demonstrated acceptable sensitivity and specificity in a sample of treatment-seeking alcoholics when compared with the PRISM as the reference standard for ADHD diagnosis. © The Author(s) 2016.

  5. Competition and the Reference Pricing Scheme for pharmaceuticals.

    Science.gov (United States)

    Ghislandi, Simone

    2011-12-01

    By introducing n (>1) firms with infinite cross-price elasticity (i.e. generic drugs), we explore the effects of competition on the optimal pricing strategies under a Reference Pricing Scheme (RPS). A two-stage model repeated infinite number of times is presented. When stage 1 is competitive, the equilibrium in pure strategies exists and is efficient only if the reference price (R) does not depend on the price of the branded product. When generics collude, the way R is designed is crucial for both the stability of the cartel among generics and the collusive prices in equilibrium. An optimally designed RPS must set R as a function only of the infinitely elastic side of the market and should provide the right incentives for competition. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Learning from Experiments in Optimization

    DEFF Research Database (Denmark)

    Winthereik, Brit Ross; Jensen, Casper Bruun

    2017-01-01

    This article examines attempts by professionals in the Danish branch of the environmental NGO NatureAid to optimize their practice by developing a local standard. Describing these efforts as an experiment in optimization, we outline a post-critical alternative to critiques that centre on the redu...... of management as ‘broken up;’ as a distributed, ambient activity, variably performed by different actors using different standards....

  7. A Comparison Between the OSI Reference Model and the B-ISDN Protocol Reference Model

    DEFF Research Database (Denmark)

    Staalhagen, Lars

    1996-01-01

    This article aims at comparing the Open Systems Interconnection (OSI) Reference Model (RM) and the broadband integrated services digital network (B-ISDN) Protocol Reference Model (PRM). According to the International Telecommunications Union - Telecommunications Sector (ITU-T), the exact...... relationship between the lower layers of the OSI RM and the B-ISDN PRM is for further study. It is therefore the intention of this article to present some views on these relationships which hopefully could facilitate an interconnection between B-ISDN and data networks conforming to the OSI standards....

  8. Standard reference and other important nuclear data. Supplement 1 to the report BNL-NCS-51123 (Dec. 1979) = ENDF-300 = IAEA-NDS-15/300 (microfiche)

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, M R [ed.

    1981-03-01

    The document contains inserts to be added to the report `Standard Reference and Other Important Nuclear Data` (BNL-NCS-51123, ENDF-300), including the following two articles: Fast Neutron Capture in {sup 238}U and {sup 232}Th by W.P. Poentiz (ANL), and {sup 239}Pu Decay Power Discrepancy by T.R. England and P.G. Young (LANL) Refs, figs

  9. Uncertainty Analysis of Spectral Irradiance Reference Standards Used for NREL Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Andreas, A.; Reda, I.; Campanelli, M.; Stoffel, T.

    2013-05-01

    Spectral irradiance produced by lamp standards such as the National Institute of Standards and Technology (NIST) FEL-type tungsten halogen lamps are used to calibrate spectroradiometers at the National Renewable Energy Laboratory. Spectroradiometers are often used to characterize spectral irradiance of solar simulators, which in turn are used to characterize photovoltaic device performance, e.g., power output and spectral response. Therefore, quantifying the calibration uncertainty of spectroradiometers is critical to understanding photovoltaic system performance. In this study, we attempted to reproduce the NIST-reported input variables, including the calibration uncertainty in spectral irradiance for a standard NIST lamp, and quantify uncertainty for measurement setup at the Optical Metrology Laboratory at the National Renewable Energy Laboratory.

  10. HYGIEN AND TECHNOLOGY OF SMOKED SALMON’S PRODUCTION: COMPARISON BETWEEN STANDARD HEALTLY REFERENCE OF EUROPEAN LEGISLATION AND AN EXTRACOMUNITY ONE

    Directory of Open Access Journals (Sweden)

    E.M. Mannocchi

    2013-02-01

    Full Text Available The work makes a comparison between European and Switzerland legislation through an inspection in an artisan producing smoked salmon factory. The analysis of HACCP plan, technology and microbiological characteristic of finished product, as enshrined in Switzerland law, allow to categorize the business risk level respect the European reference. The criticalities detected are: Listeria monocytogenes and Anisakis spp.. A plain was developed for improving the hygienic characteristic of the production to ensure the alignment of structure to the standards specified by the European requirements and allow to the factory send his products inside the European market.

  11. 77 FR 202 - Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting References

    Science.gov (United States)

    2012-01-03

    ... 9000-AM00 Federal Acquisition Regulation; Updated Financial Accounting Standards Board Accounting... accounting standards owing to the Financial Accounting Standards Board's Accounting Standards Codification of Generally Accepted Accounting Principles. DATES: Effective Date: February 2, 2012. FOR FURTHER INFORMATION...

  12. Selection of optimal treatment procedures for non-standard radioactive waste arising from decommissioning of NPP after accident

    Energy Technology Data Exchange (ETDEWEB)

    Strážovec, Roman, E-mail: strazovec.roman@javys.sk [Institute of Nuclear and Physical Engineering, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19 Bratislava (Slovakia); JAVYS, a.s., Tomášikova 22, 821 02 Bratislava (Slovakia); Hrnčíř, Tomáš [DECOM, a.s., Sibírska 1, 917 01 Trnava (Slovakia); Lištjak, Martin [Institute of Nuclear and Physical Engineering, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19 Bratislava (Slovakia); VUJE, a.s., Okružná 5, 918 64 Trnava (Slovakia); Nečas, Vladimír [Institute of Nuclear and Physical Engineering, Slovak University of Technology in Bratislava, Ilkovičova 3, 812 19 Bratislava (Slovakia)

    2016-05-15

    The decommissioning of nuclear power plants is becoming a standard industrial activity where the optimization processes of partial activities are inevitable mainly for technical and economic reasons. In Slovakia, the decommissioning of A1 NPP is very specific case because A1 NPP is rare type of NPP (prototype) and furthermore its operation was affected by the accident. A large number of specific non-standard radioactive waste, such as long-time storage cases (hereinafter LSC), that is not usually present within the decommissioning projects of NPP with a regular termination of operation, represent one of the significant consequences of the accident and issues arisen from follow-up activities. The presented article describes the proposal of processing and conditioning of non-standard radioactive waste (such as LSC), together with description of methodology applied in the proposal for update of waste acceptance criteria for the processing and conditioning of radioactive waste (hereinafter RAW) within Bohunice Radioactive waste Treatment and Conditioning Centre (hereinafter RWTC). The results of performed detailed analysis are summarized into new waste acceptance criteria for technological lines keeping in mind safety principles and requirements for protection of operating personnel, the public and the environment.

  13. ISO radiation protection standards

    International Nuclear Information System (INIS)

    Becker, K.; West, N.

    1981-01-01

    After a brief description of the International Organization for Standardization (ISO) and its Technical Committee (TC) 85 ''Nuclear Energy'', the work of its Sub-Committee (SC) 2 ''Radiation Protection'' is described in some detail. Several international standards on subjects closely related to radiation protection have already been published, for example ISO-361 (Basic radiation protection symbol), ISO-1757 (Photographic dosimeters), ISO-1758 and 1759 (Direct and indirect-reading pocket exposure meters), ISO-2889 (Sampling of airborne radioactive materials), ISO-4037 (X and gamma reference radiations for calibration) and ISO-4071 (Testing of exposure meters and dosimeters). TC 85/SC 2 has currently eight active Working Groups (WG) dealing with 14 standards projects, mostly in advanced stages, in such fields as neutron and beta reference radiations, and X and gamma radiations of high and low dose-rates and high energies for calibration purposes, reference radiations for surface contamination apparatus, ejection systems for gamma radiography apparatus, industrial and laboratory irradiators, lead shielding units, protective clothing, thermoluminescence dosemeters, radioelement gauges, and surface contamination and decontamination. (author)

  14. Calibration of surface roughness standards

    DEFF Research Database (Denmark)

    Thalmann, R.; Nicolet, A.; Meli, F.

    2016-01-01

    organisations. Five surface texture standards of different type were circulated and on each of the standards several roughness parameters according to the standard ISO 4287 had to be determined. 32 out of 395 individual results were not consistent with the reference value. After some corrective actions...

  15. Establishment of Traceability of Reference Grade Hydrometers at National Physical Laboratory, India (npli)

    Science.gov (United States)

    Kumar, Anil; Kumar, Harish; Mandal, Goutam; Das, M. B.; Sharma, D. C.

    The present paper discusses the establishment of traceability of reference grade hydrometers at National Physical Laboratory, India (NPLI). The reference grade hydrometers are calibrated and traceable to the primary solid density standard. The calibration has been done according to standard procedure based on Cuckow's Method and the reference grade hydrometers calibrated covers a wide range. The uncertainty of the reference grade hydrometers has been computed and corrections are also calculated for the scale readings, at which observations are taken.

  16. 10 CFR 63.305 - Required characteristics of the reference biosphere.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Required characteristics of the reference biosphere. 63... Standards § 63.305 Required characteristics of the reference biosphere. (a) Features, events, and processes that describe the reference biosphere must be consistent with present knowledge of the conditions in...

  17. An Optimization Framework for Load and Power Distribution in Wind Farms

    DEFF Research Database (Denmark)

    Soleimanzadeh, Maryam; Wisniewski, Rafal; Kanev, Stoyan

    2012-01-01

    The aim of this paper is to develop a controller for wind farms to optimize the load and power distribution. In this regard, the farm controller calculates the power reference signals for individual wind turbine controllers such that the sum of the power references tracks the power demanded...... by a system operator. Moreover, the reference signals are determined to reduce the load acting on wind turbines at low frequencies. Therefore, a trade-off is made for load and power control, which is formulated as an optimization problem. Afterwards, the optimization problem for the wind farm modeled...

  18. Comparing the role of standard references on the prevalence of Iranian children and adolescents' overweight and obesity: A systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Saeed Ghanbari

    2016-01-01

    Full Text Available Background: Obesity is a major risk factor for chronic diseases and has a role on high blood pressure, diabetes type II, etc., This review assesses the prevalence of Iranian children obesity and overweight for different age categories and compares the three standard definitions of obesity. Materials and Methods: To retrieve desirable studies concerning childhood anthropometric data from different area of Iran, the MEDLINE, Scopus, and different local databases such as Scientific Information database were used. The studies reported the prevalence of obesity or overweight of children < 6, 6–12, and 12–20 years old, despite differences between definitions of childhood obesity, were included in the study. We combined the reported prevalence of the overweight and obesity with regard to age and gender, and also by the different standard references which are the Centers for Disease Control and Prevention (CDC, the World Health Organization (WHO definition, and the International Obesity Task Force (IOTF references. The analysis was carried out using STATA software. Results: Our review covered 75 articles reported the prevalence of overweight or obesity among children and adolescents for different age groups in Iran. Our meta-regression analysis showed that the prevalence of obesity and overweight did not vary significantly in gender and age categories, but different definitions provide different prevalence of overweight and obesity. Conclusion: The effective factors on obesity and overweight included administration policy and organizational, interpersonal, intrapersonal, and social factors. CDC and WHO references intended in monitoring children's growth and the IOTF cutoffs would rather provide a common set of definitions that researchers and policymakers could use for descriptive and comparative purposes.

  19. Characterization of the Defense Waste Processing Facility (DWPF) Environmental Assessment (EA) glass Standard Reference Material. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Crawford, C.L.; Pickett, M.A.

    1993-06-01

    Liquid high-level nuclear waste at the Savannah River Site (SRS) will be immobilized by vitrification in borosilicate glass. The glass will be produced and poured into stainless steel canisters in the Defense Waste Processing Facility (DWPF). Other waste form producers, such as West Valley Nuclear Services (WVNS) and the Hanford Waste Vitrification Project (HWVP), will also immobilize high-level radioactive waste in borosilicate glass. The canistered waste will be stored temporarily at each facility for eventual permanent disposal in a geologic repository. The Department of Energy has defined a set of requirements for the canistered waste forms, the Waste Acceptance Product Specifications (WAPS). The current Waste Acceptance Primary Specification (WAPS) 1.3, the product consistency specification, requires the waste form producers to demonstrate control of the consistency of the final waste form using a crushed glass durability test, the Product Consistency Test (PCI). In order to be acceptable, a waste glass must be more durable during PCT analysis than the waste glass identified in the DWPF Environmental Assessment (EA). In order to supply all the waste form producers with the same standard benchmark glass, 1000 pounds of the EA glass was fabricated. The chemical analyses and characterization of the benchmark EA glass are reported. This material is now available to act as a durability and/or redox Standard Reference Material (SRM) for all waste form producers.

  20. Point-based warping with optimized weighting factors of displacement vectors

    Science.gov (United States)

    Pielot, Ranier; Scholz, Michael; Obermayer, Klaus; Gundelfinger, Eckart D.; Hess, Andreas

    2000-06-01

    The accurate comparison of inter-individual 3D image brain datasets requires non-affine transformation techniques (warping) to reduce geometric variations. Constrained by the biological prerequisites we use in this study a landmark-based warping method with weighted sums of displacement vectors, which is enhanced by an optimization process. Furthermore, we investigate fast automatic procedures for determining landmarks to improve the practicability of 3D warping. This combined approach was tested on 3D autoradiographs of Gerbil brains. The autoradiographs were obtained after injecting a non-metabolized radioactive glucose derivative into the Gerbil thereby visualizing neuronal activity in the brain. Afterwards the brain was processed with standard autoradiographical methods. The landmark-generator computes corresponding reference points simultaneously within a given number of datasets by Monte-Carlo-techniques. The warping function is a distance weighted exponential function with a landmark- specific weighting factor. These weighting factors are optimized by a computational evolution strategy. The warping quality is quantified by several coefficients (correlation coefficient, overlap-index, and registration error). The described approach combines a highly suitable procedure to automatically detect landmarks in autoradiographical brain images and an enhanced point-based warping technique, optimizing the local weighting factors. This optimization process significantly improves the similarity between the warped and the target dataset.

  1. 15 CFR 230.7 - Description of services and list of fees, incorporation by reference.

    Science.gov (United States)

    2010-01-01

    ... STANDARD REFERENCE MATERIALS STANDARD REFERENCE MATERIALS Description of Services and List of Fees § 230.7 Description of services and list of fees, incorporation by reference. (a) The text of NIST Special Publication... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Description of services and list of...

  2. Element concentrations in candidate biological and environmental reference materials by k0-standardized INAA

    International Nuclear Information System (INIS)

    Freitas, M.C.

    1993-01-01

    K 0 -Based Neutron Activation Analysis (k 0 INAA) was used to analyze the candidate reference materials Apple Leaves and Peach Leaves, and Oriental Tobacco Leaves and Virginia Tobacco Leaves. Concentration values for 27 elements were measured. The accuracy was ascertained by analysis of two certified reference materials. NIST 1572 Citrus Leaves and 1573 Tomato Leaves. The homogeneity test of the IAEA Evernia prunastri candidate reference material in aliquots ≥ 100 mg is extended to the elements Sc, Cr, Fe, Co, Zn, Rb, Sb, Cs, Ba, Ce and Th. (orig.)

  3. Solid phase speciation of arsenic by sequential extraction in standard reference materials and industrially contaminated soil samples

    International Nuclear Information System (INIS)

    Herreweghe, Samuel van; Swennen, Rudy; Vandecasteele, Carlo; Cappuyns, Valerie

    2003-01-01

    Leaching experiments, a mineralogical survey and larger samples are preferred when arsenic is present as discrete mineral phases. - Availability, mobility, (phyto)toxicity and potential risk of contaminants is strongly affected by the manner of appearance of elements, the so-called speciation. Operational fractionation methods like sequential extractions have been applied for a long time to determine the solid phase speciation of heavy metals since direct determination of specific chemical compounds can not always be easily achieved. The three-step sequential extraction scheme recommended by the BCR and two extraction schemes based on the phosphorus-like protocol proposed by Manful (1992, Occurrence and Ecochemical Behaviours of Arsenic in a Goldsmelter Impacted Area in Ghana, PhD dissertation, at the RUG) were applied to four standard reference materials (SRM) and to a batch of samples from industrially contaminated sites, heavily contaminated with arsenic and heavy metals. The SRM 2710 (Montana soil) was found to be the most useful reference material for metal (Mn, Cu, Zn, As, Cd and Pb) fractionation using the BCR sequential extraction procedure. Two sequential extraction schemes were developed and compared for arsenic with the aim to establish a better fractionation and recovery rate than the BCR-scheme for this element in the SRM samples. The major part of arsenic was released from the heavily contaminated samples after NaOH-extraction. Inferior extraction variability and recovery in the heavily contaminated samples compared to SRMs could be mainly contributed to subsample heterogeneity

  4. Quality assessment of Chrysanthemum indicum Flower by simultaneous quantification of six major ingredients using a single reference standard combined with HPLC fingerprint analysis

    Directory of Open Access Journals (Sweden)

    Jiao He

    2016-04-01

    Full Text Available Chrysanthemum indicum Flower is usually consumed as functional food. This paper described an improved total quality assessment method for Chrysanthemum indicum Flower by simultaneous quantitation using a single standard to determine multi-components method combined with high performance liquid chromatography fingerprint analysis. Six main components of Chrysanthemum indicum Flower including two flavonoids and four phenolic acids were simultaneously quantified using linarin as the internal reference standard. The method was fully validated with respect to linearity, precision, accuracy, robustness and stability. The validated method was successfully applied to the analysis of thirty three batches of Chrysanthemum indicum Flower samples. Under the same chromatographic conditions, fingerprint analysis in combination with Similarity analysis and principal component analysis was performed to identify the samples from different regions. In general, an effective assessment using a single standard to determinate multi-components method combined with fingerprint analysis make the reliable qualitation and quantitation analysis of Chrysanthemum indicum Flower available.

  5. Technological, Economic, and Environmental Optimization of Aluminum Recycling

    Science.gov (United States)

    Ioana, Adrian; Semenescu, Augustin

    2013-08-01

    The four strategic directions (referring to the entire life cycle of aluminum) are as follows: production, primary use, recycling, and reuse. Thus, in this work, the following are analyzed and optimized: reducing greenhouse gas emissions from aluminum production, increasing energy efficiency in aluminum production, maximizing used-product collection, recycling, and reusing. According to the energetic balance at the gaseous environment level, the conductive transfer model is also analyzed through the finished elements method. Several principles of modeling and optimization are presented and analyzed: the principle of analogy, the principle of concepts, and the principle of hierarchization. Based on these principles, an original diagram model is designed together with the corresponding logic diagram. This article also presents and analyzes the main benefits of aluminum recycling and reuse. Recycling and reuse of aluminum have the main advantage that it requires only about 5% of energy consumed to produce it from bauxite. The aluminum recycling and production process causes the emission of pollutants such as dioxides and furans, hydrogen chloride, and particulate matter. To control these emissions, aluminum recyclers are required to comply with the National Emission Standards for Hazardous Air Pollutants for Secondary Aluminum Production. The results of technological, economic, and ecological optimization of aluminum recycling are based on the criteria function's evaluation in the modeling system.

  6. INTERDEPENDENCIES OF THE INTERNAL / MANAGERIAL CONTROL STANDARD NO. 6 - ORGANIZATIONAL STRUCTURE

    Directory of Open Access Journals (Sweden)

    Ionut-Cosmin BĂLOI

    2015-06-01

    Full Text Available Our initiative of analyzing the internal control standard which deals with the organizational structure comes from the observations on the significance of these essential aspects of modern management and on the sensitivity with which this standard is treated in most of the public institutions considered representative for the Oltenia region. Although the administrators of public institutions strive to optimize the systems of internal/managerial control, they frequently face many issues concerning the misunderstanding of these standards, vaguely explained, for example throughout some guidelines or other documents. The hypothesis of our study is that most of public institutions face gaps in understanding, interpreting, adapting and implementing an effective model of organizational structure, and the causes are due to the lack of an interdependent, correlated approach of the pillars that support the internal/managerial control system: the 25 standards required by the Romanian legislation. Our study critically describes the superficial approach founded in the self-evaluation reports of the public institutions, if we refer only to the conformity of the organizational structure and the four standards that we consider inextricably related with this internal/managerial control standard. From the methodological point of view, our study tests the correlation between the level of compliance of these standards and the functionality of the system composed by them in the public organizations that we have investigated.

  7. A word processor optimized for preparing journal articles and student papers.

    Science.gov (United States)

    Wolach, A H; McHale, M A

    2001-11-01

    A new Windows-based word processor for preparing journal articles and student papers is described. In addition to standard features found in word processors, the present word processor provides specific help in preparing manuscripts. Clicking on "Reference Help (APA Form)" in the "File" menu provides a detailed help system for entering the references in a journal article. Clicking on "Examples and Explanations of APA Form" provides a help system with examples of the various sections of a review article, journal article that has one experiment, or journal article that has two or more experiments. The word processor can automatically place the manuscript page header and page number at the top of each page using the form required by APA and Psychonomic Society journals. The "APA Form" submenu of the "Help" menu provides detailed information about how the word processor is optimized for preparing articles and papers.

  8. Optimization and radiation protection of the patient in medical exposure

    International Nuclear Information System (INIS)

    Mwambinga, S.A.

    2012-04-01

    Radiography has been an established imaging modality for over a century, continuous developments have led to improvements in technique resulting in improved image quality at reduced patient dose. If one compares the technique used by Roentgen with the methods used today, one finds that a radiograph can now be obtained at a dose which is smaller. The International Atomic Energy Agency (IAEA) has a statutory responsibility to establish standards for the protection of people against exposure to ionising radiation and to provide for the worldwide application of those standards. A fundamental requirement of the International Basic Safety Standards for Protection Against Ionizing Radiation and for the Safety of Radiation Sources (BSS) is the optimization of radiological protection of patients undergoing medical exposure. By using technique such as added filtration, use of high kVp techniques, low mAs, use of appropriate screen-film combination and making sure that all practices and any exposure to patient are justified, using ALARA principles and diagnostic Reference Levels, patient protection can be optimised. (author)

  9. Trajectory generation for manipulators using linear quadratic optimal tracking

    Directory of Open Access Journals (Sweden)

    Olav Egeland

    1989-04-01

    Full Text Available The reference trajectory is normally known in advance in manipulator control which makes it possible to apply linear quadratic optimal tracking. This gives a control system which rounds corners and generates optimal feedforward. The method may be used for references consisting of straight-line segments as an alternative to the two-step method of using splines to smooth the reference and then applying feedforward. In addition, the method can be used for more complex trajectories. The actual dynamics of the manipulator are taken into account, and this results in smooth and accurate tracking. The method has been applied in combination with the computed torque technique and excellent performance was demonstrated in a simulation study. The method has also been applied experimentally to an industrial spray-painting robot where a saw-tooth reference was tracked. The corner was rounded extremely well, and the steady-state tracking error was eliminated by the optimal feedforward.

  10. Risk Assessment References: Documented Literature Search

    Science.gov (United States)

    2012-10-01

    concepts specified in ISO /IEC 27001 and is designed to assist the satisfactory implementation of information security based on a risk management approach...Knowledge of the concepts, models, processes and terminologies described in ISO /IEC 27001 and ISO /IEC 27002 is important for a complete...Standardization ( ISO ). • Section 2.2: national standards for Canada and Australia/New Zealand. Note: Though most of the references in this section are

  11. AS Migration and Optimization of the Power Integrated Data Network

    Science.gov (United States)

    Zhou, Junjie; Ke, Yue

    2018-03-01

    In the transformation process of data integration network, the impact on the business has always been the most important reference factor to measure the quality of network transformation. With the importance of the data network carrying business, we must put forward specific design proposals during the transformation, and conduct a large number of demonstration and practice to ensure that the transformation program meets the requirements of the enterprise data network. This paper mainly demonstrates the scheme of over-migrating point-to-point access equipment in the reconstruction project of power data comprehensive network to migrate the BGP autonomous domain to the specified domain defined in the industrial standard, and to smooth the intranet OSPF protocol Migration into ISIS agreement. Through the optimization design, eventually making electric power data network performance was improved on traffic forwarding, traffic forwarding path optimized, extensibility, get larger, lower risk of potential loop, the network stability was improved, and operational cost savings, etc.

  12. Actor-critic-based optimal tracking for partially unknown nonlinear discrete-time systems.

    Science.gov (United States)

    Kiumarsi, Bahare; Lewis, Frank L

    2015-01-01

    This paper presents a partially model-free adaptive optimal control solution to the deterministic nonlinear discrete-time (DT) tracking control problem in the presence of input constraints. The tracking error dynamics and reference trajectory dynamics are first combined to form an augmented system. Then, a new discounted performance function based on the augmented system is presented for the optimal nonlinear tracking problem. In contrast to the standard solution, which finds the feedforward and feedback terms of the control input separately, the minimization of the proposed discounted performance function gives both feedback and feedforward parts of the control input simultaneously. This enables us to encode the input constraints into the optimization problem using a nonquadratic performance function. The DT tracking Bellman equation and tracking Hamilton-Jacobi-Bellman (HJB) are derived. An actor-critic-based reinforcement learning algorithm is used to learn the solution to the tracking HJB equation online without requiring knowledge of the system drift dynamics. That is, two neural networks (NNs), namely, actor NN and critic NN, are tuned online and simultaneously to generate the optimal bounded control policy. A simulation example is given to show the effectiveness of the proposed method.

  13. The preparation of large standards for NDA measurements

    International Nuclear Information System (INIS)

    Guardini, S.

    1991-01-01

    The accuracy of a nuclear material balance determination is dependent on the reference materials used to calibrate. The calibration needs of nondestructive assay techniques differ from the needs of destructive techniques: nondestructive techniques use the reference materials more than once and can require larger masses of special nuclear material. Therefore, the expertise inherited from destructive methods is not destructive measurements. The procurement process for reference materials is expensive and complex. Careful specification of the desired attributes defines the required quality measures. A detailed procurement plan, agreed upon and documented before acquisition starts, is crucial to obtaining a set of high quality references materials. The acquisition of some recent Los Alamos standards and the Ispra PERLA (Performance Laboratory) standards are following such plans. To date, plutonium oxide standards of three burnups ranging to 2.5 kg and uranium oxide standards of four (high) enrichments ranging to 1.5 kg are in routine use for calibration, performance evaluation and training. In this paper, the authors discuss an alternative

  14. 49 CFR 393.7 - Matter incorporated by reference.

    Science.gov (United States)

    2010-10-01

    ... § 393.104(e). (20) Recommended Standard Specification for Synthetic Web Tiedowns, Web Sling and Tiedown..., 2nd Edition, Wire Rope Technical Board November 1985, incorporation by reference approved for § 393... Composite Rope Specifications, Three-Strand and Eight-Strand Standard Construction, May 1979; (iv) NRS-1...

  15. Pulse Wave Velocity as Marker of Preclinical Arterial Disease: Reference Levels in a Uruguayan Population Considering Wave Detection Algorithms, Path Lengths, Aging, and Blood Pressure

    Directory of Open Access Journals (Sweden)

    Ignacio Farro

    2012-01-01

    Full Text Available Carotid-femoral pulse wave velocity (PWV has emerged as the gold standard for non-invasive evaluation of aortic stiffness; absence of standardized methodologies of study and lack of normal and reference values have limited a wider clinical implementation. This work was carried out in a Uruguayan (South American population in order to characterize normal, reference, and threshold levels of PWV considering normal age-related changes in PWV and the prevailing blood pressure level during the study. A conservative approach was used, and we excluded symptomatic subjects; subjects with history of cardiovascular (CV disease, diabetes mellitus or renal failure; subjects with traditional CV risk factors (other than age and gender; asymptomatic subjects with atherosclerotic plaques in carotid arteries; patients taking anti-hypertensives or lipid-lowering medications. The included subjects (n=429 were categorized according to the age decade and the blood pressure levels (at study time. All subjects represented the “reference population”; the group of subjects with optimal/normal blood pressures levels at study time represented the “normal population.” Results. Normal and reference PWV levels were obtained. Differences in PWV levels and aging-associated changes were obtained. The obtained data could be used to define vascular aging and abnormal or disease-related arterial changes.

  16. On Translators' Cultural Frame of Functionist Reference

    Science.gov (United States)

    Fu, Zhiyi

    2009-01-01

    A deep cognition with translators' cultural frame of functionist reference can help instructors and teachers adjust and extend patterns and schemes of translation and generate the optimal classroom conditions for acquisition of the target language. The author of the paper, in the perspectives of motivational, cognitive and communicative…

  17. Printed circuit board designer's reference basics

    CERN Document Server

    Robertson, Chris

    2003-01-01

    PCB design instruction and reference manual, all in one book, with in- depth explanation of the processes and tools used in modern PCB design Standards, formulas, definitions, and procedures, plus software to tie it all together.

  18. Optimal covariate designs theory and applications

    CERN Document Server

    Das, Premadhis; Mandal, Nripes Kumar; Sinha, Bikas Kumar

    2015-01-01

    This book primarily addresses the optimality aspects of covariate designs. A covariate model is a combination of ANOVA and regression models. Optimal estimation of the parameters of the model using a suitable choice of designs is of great importance; as such choices allow experimenters to extract maximum information for the unknown model parameters. The main emphasis of this monograph is to start with an assumed covariate model in combination with some standard ANOVA set-ups such as CRD, RBD, BIBD, GDD, BTIBD, BPEBD, cross-over, multi-factor, split-plot and strip-plot designs, treatment control designs, etc. and discuss the nature and availability of optimal covariate designs. In some situations, optimal estimations of both ANOVA and the regression parameters are provided. Global optimality and D-optimality criteria are mainly used in selecting the design. The standard optimality results of both discrete and continuous set-ups have been adapted, and several novel combinatorial techniques have been applied for...

  19. Performance analysis of Supply Chain Management with Supply Chain Operation reference model

    Science.gov (United States)

    Hasibuan, Abdurrozzaq; Arfah, Mahrani; Parinduri, Luthfi; Hernawati, Tri; Suliawati; Harahap, Bonar; Rahmah Sibuea, Siti; Krianto Sulaiman, Oris; purwadi, Adi

    2018-04-01

    This research was conducted at PT. Shamrock Manufacturing Corpora, the company is required to think creatively to implement competition strategy by producing goods/services that are more qualified, cheaper. Therefore, it is necessary to measure the performance of Supply Chain Management in order to improve the competitiveness. Therefore, the company is required to optimize its production output to meet the export quality standard. This research begins with the creation of initial dimensions based on Supply Chain Management process, ie Plan, Source, Make, Delivery, and Return with hierarchy based on Supply Chain Reference Operation that is Reliability, Responsiveness, Agility, Cost, and Asset. Key Performance Indicator identification becomes a benchmark in performance measurement whereas Snorm De Boer normalization serves to equalize Key Performance Indicator value. Analiytical Hierarchy Process is done to assist in determining priority criteria. Measurement of Supply Chain Management performance at PT. Shamrock Manufacturing Corpora produces SC. Responsiveness (0.649) has higher weight (priority) than other alternatives. The result of performance analysis using Supply Chain Reference Operation model of Supply Chain Management performance at PT. Shamrock Manufacturing Corpora looks good because its monitoring system between 50-100 is good.

  20. A standardization of the physical tests for external irradiation measuring detectors

    International Nuclear Information System (INIS)

    1977-05-01

    This report is the result of a standardization work, realized within the Radioprotection Services of the A.E.C., of the physical tests for dectors measuring external irradiations. Among the various tests mentionned, calibration and the establishment of the relative spectral response are treated in details. As far as calibration is concerned, the standardization refers to: the reference detector, the reference radiation source, the installation and calibration procedure. As for the relative spectral response the standardization refers to: the reference detector, the radiation sources to be used. High flux detectors and those for pulse electromagnetic radiations are also dealt with [fr

  1. Quality assurance for high dose rate brachytherapy treatment planning optimization: using a simple optimization to verify a complex optimization

    International Nuclear Information System (INIS)

    Deufel, Christopher L; Furutani, Keith M

    2014-01-01

    As dose optimization for high dose rate brachytherapy becomes more complex, it becomes increasingly important to have a means of verifying that optimization results are reasonable. A method is presented for using a simple optimization as quality assurance for the more complex optimization algorithms typically found in commercial brachytherapy treatment planning systems. Quality assurance tests may be performed during commissioning, at regular intervals, and/or on a patient specific basis. A simple optimization method is provided that optimizes conformal target coverage using an exact, variance-based, algebraic approach. Metrics such as dose volume histogram, conformality index, and total reference air kerma agree closely between simple and complex optimizations for breast, cervix, prostate, and planar applicators. The simple optimization is shown to be a sensitive measure for identifying failures in a commercial treatment planning system that are possibly due to operator error or weaknesses in planning system optimization algorithms. Results from the simple optimization are surprisingly similar to the results from a more complex, commercial optimization for several clinical applications. This suggests that there are only modest gains to be made from making brachytherapy optimization more complex. The improvements expected from sophisticated linear optimizations, such as PARETO methods, will largely be in making systems more user friendly and efficient, rather than in finding dramatically better source strength distributions. (paper)

  2. Taking Stock of Unrealistic Optimism.

    Science.gov (United States)

    Shepperd, James A; Klein, William M P; Waters, Erika A; Weinstein, Neil D

    2013-07-01

    Researchers have used terms such as unrealistic optimism and optimistic bias to refer to concepts that are similar but not synonymous. Drawing from three decades of research, we critically discuss how researchers define unrealistic optimism and we identify four types that reflect different measurement approaches: unrealistic absolute optimism at the individual and group level and unrealistic comparative optimism at the individual and group level. In addition, we discuss methodological criticisms leveled against research on unrealistic optimism and note that the criticisms are primarily relevant to only one type-the group form of unrealistic comparative optimism. We further clarify how the criticisms are not nearly as problematic even for unrealistic comparative optimism as they might seem. Finally, we note boundary conditions on the different types of unrealistic optimism and reflect on five broad questions that deserve further attention.

  3. Taking Stock of Unrealistic Optimism

    Science.gov (United States)

    Shepperd, James A.; Klein, William M. P.; Waters, Erika A.; Weinstein, Neil D.

    2015-01-01

    Researchers have used terms such as unrealistic optimism and optimistic bias to refer to concepts that are similar but not synonymous. Drawing from three decades of research, we critically discuss how researchers define unrealistic optimism and we identify four types that reflect different measurement approaches: unrealistic absolute optimism at the individual and group level and unrealistic comparative optimism at the individual and group level. In addition, we discuss methodological criticisms leveled against research on unrealistic optimism and note that the criticisms are primarily relevant to only one type—the group form of unrealistic comparative optimism. We further clarify how the criticisms are not nearly as problematic even for unrealistic comparative optimism as they might seem. Finally, we note boundary conditions on the different types of unrealistic optimism and reflect on five broad questions that deserve further attention. PMID:26045714

  4. STANDARDIZING QUALITY ASSESSMENT OF FUSED REMOTELY SENSED IMAGES

    Directory of Open Access Journals (Sweden)

    C. Pohl

    2017-09-01

    Full Text Available The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  5. Standardizing Quality Assessment of Fused Remotely Sensed Images

    Science.gov (United States)

    Pohl, C.; Moellmann, J.; Fries, K.

    2017-09-01

    The multitude of available operational remote sensing satellites led to the development of many image fusion techniques to provide high spatial, spectral and temporal resolution images. The comparison of different techniques is necessary to obtain an optimized image for the different applications of remote sensing. There are two approaches in assessing image quality: 1. Quantitatively by visual interpretation and 2. Quantitatively using image quality indices. However an objective comparison is difficult due to the fact that a visual assessment is always subject and a quantitative assessment is done by different criteria. Depending on the criteria and indices the result varies. Therefore it is necessary to standardize both processes (qualitative and quantitative assessment) in order to allow an objective image fusion quality evaluation. Various studies have been conducted at the University of Osnabrueck (UOS) to establish a standardized process to objectively compare fused image quality. First established image fusion quality assessment protocols, i.e. Quality with No Reference (QNR) and Khan's protocol, were compared on varies fusion experiments. Second the process of visual quality assessment was structured and standardized with the aim to provide an evaluation protocol. This manuscript reports on the results of the comparison and provides recommendations for future research.

  6. Detection of heart rate and rhythm with a smartphone-based electrocardiograph versus a reference standard electrocardiograph in dogs and cats.

    Science.gov (United States)

    Kraus, Marc S; Gelzer, Anna R; Rishniw, Mark

    2016-07-15

    OBJECTIVE To evaluate the diagnostic utility of ECGs acquired with a smartphone-based device, compared with reference 6-lead ECGs, for identification of heart rate and rhythm in dogs and cats. DESIGN Prospective study. ANIMALS 51 client-owned dogs and 27 client-owned cats. PROCEDURES Patients examined by a small animal referral cardiology service between April 2012 and January 2013 were enrolled consecutively. In each patient, a 30-second ECG was simultaneously acquired with a smartphone-based device (a bipolar, single-lead recorder coupled to a smartphone with an ECG application) and a standard 6-lead ECG machine. Recordings were evaluated by 3 board-certified cardiologists, and intra- and interobserver agreement were evaluated for both rhythm diagnosis and QRS polarity identification. RESULTS Values for instantaneous and mean heart rates for the smartphone-acquired and reference ECGs were within 1 beat of each other when mean heart rates were calculated. Intraobserver agreement for rhythm assessment was very high, with maximum disagreement for any observer for only 2 of 51 dogs and only 4 of 27 cats. There was minimal disagreement in the polarity of depolarization between the smartphone-acquired and reference ECGs in dogs but frequent disagreement in cats. Interobserver agreement for smartphone-acquired ECGs was similar to that for reference ECGs. with all 3 observers agreeing on the rhythm analysis and minimal disagreement on polarity. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ECGs acquired with the smartphone-based device accurately identified heart rate and rhythm in dogs and cats. Thus, the device may allow veterinarians to evaluate and manage cardiac arrhythmias relatively inexpensively at the cage side and could also allow clinicians to rapidly share information via email for further consultation, potentially enhancing patient care.

  7. Tibiofemoral wear in standard and non-standard squat: implication for total knee arthroplasty.

    Science.gov (United States)

    Fekete, Gusztáv; Sun, Dong; Gu, Yaodong; Neis, Patric Daniel; Ferreira, Ney Francisco; Innocenti, Bernardo; Csizmadia, Béla M

    2017-01-01

    Due to the more resilient biomaterials, problems related to wear in total knee replacements (TKRs) have decreased but not disappeared. In the design-related factors, wear is still the second most important mechanical factor that limits the lifetime of TKRs and it is also highly influenced by the local kinematics of the knee. During wear experiments, constant load and slide-roll ratio is frequently applied in tribo-tests beside other important parameters. Nevertheless, numerous studies demonstrated that constant slide-roll ratio is not accurate approach if TKR wear is modelled, while instead of a constant load, a flexion-angle dependent tibiofemoral force should be involved into the wear model to obtain realistic results. A new analytical wear model, based upon Archard's law, is introduced, which can determine the effect of the tibiofemoral force and the varying slide-roll on wear between the tibiofemoral connection under standard and non-standard squat movement. The calculated total wear with constant slide-roll during standard squat was 5.5 times higher compared to the reference value, while if total wear includes varying slide-roll during standard squat, the calculated wear was approximately 6.25 times higher. With regard to non-standard squat, total wear with constant slide-roll during standard squat was 4.16 times higher than the reference value. If total wear included varying slide-roll, the calculated wear was approximately 4.75 times higher. It was demonstrated that the augmented force parameter solely caused 65% higher wear volume while the slide-roll ratio itself increased wear volume by 15% higher compared to the reference value. These results state that the force component has the major effect on wear propagation while non-standard squat should be proposed for TKR patients as rehabilitation exercise.

  8. Reference genes for gene expression analysis by real-time reverse transcription polymerase chain reaction of renal cell carcinoma.

    Science.gov (United States)

    Bjerregaard, Henriette; Pedersen, Shona; Kristensen, Søren Risom; Marcussen, Niels

    2011-12-01

    Differentiation between malignant renal cell carcinoma and benign oncocytoma is of great importance to choose the optimal treatment. Accurate preoperative diagnosis of renal tumor is therefore crucial; however, existing imaging techniques and histologic examinations are incapable of providing an optimal differentiation profile. Analysis of gene expression of molecular markers is a new possibility but relies on appropriate standardization to compare different samples. The aim of this study was to identify stably expressed reference genes suitable for the normalization of results extracted from gene expression analysis of renal tumors. Expression levels of 8 potential reference genes (ATP5J, HMBS, HPRT1, PPIA, TBP, 18S, GAPDH, and POLR2A) were examined by real-time reverse transcription polymerase chain reaction in tumor and normal tissue from removed kidneys from 13 patients with renal cell carcinoma and 5 patients with oncocytoma. The expression levels of genes were compared by gene stability value M, average gene stability M, pairwise variation V, and coefficient of variation CV. More candidates were not suitable for the purpose, but a combination of HMBS, PPIA, ATP5J, and TBP was found to be the best combination with an average gene stability value M of 0.9 and a CV of 0.4 in the 18 tumors and normal tissues. A combination of 4 genes, HMBS, PPIA, ATP5J, and TBP, is a possible reference in renal tumor gene expression analysis by reverse transcription polymerase chain reaction. A combination of four genes, HMBS, PPIA, ATP5J and TBP, being stably expressed in tissues from RCC is possible reference genes for gene expression analysis.

  9. Computation of a Reference Model for Robust Fault Detection and Isolation Residual Generation

    Directory of Open Access Journals (Sweden)

    Emmanuel Mazars

    2008-01-01

    Full Text Available This paper considers matrix inequality procedures to address the robust fault detection and isolation (FDI problem for linear time-invariant systems subject to disturbances, faults, and polytopic or norm-bounded uncertainties. We propose a design procedure for an FDI filter that aims to minimize a weighted combination of the sensitivity of the residual signal to disturbances and modeling errors, and the deviation of the faults to residual dynamics from a fault to residual reference model, using the ℋ∞-norm as a measure. A key step in our procedure is the design of an optimal fault reference model. We show that the optimal design requires the solution of a quadratic matrix inequality (QMI optimization problem. Since the solution of the optimal problem is intractable, we propose a linearization technique to derive a numerically tractable suboptimal design procedure that requires the solution of a linear matrix inequality (LMI optimization. A jet engine example is employed to demonstrate the effectiveness of the proposed approach.

  10. [Studies on the identification of psychotropic substances. VIII. Preparation and various analytical data of reference standard of some stimulants, amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex].

    Science.gov (United States)

    Shimamine, M; Takahashi, K; Nakahara, Y

    1992-01-01

    The Reference Standards for amfepramone, cathinone, N-ethylamphetamine, fenethylline, fenproporex and mefenorex were prepared. Their purities determined by HPLC were more than 99.5%. For the identification and determination of these six drugs, their analytical data were measured and discussed by TLC, UV, IR, HPLC, GC/MS and NMR.

  11. Non-destructive alpha-particle activation analysis of P, Cl, K and Ca in marine macro-alga samples using synthetic multielement reference material as comparative standard

    International Nuclear Information System (INIS)

    Iwata, Y.; Naitoh, H.; Suzuki, N.

    1992-01-01

    A Synthetic Reference Material (SyRM) composed with accurately known amounts of 12 elements has been prepared. The elemental composition of the SyRM is closely similar to that of marine macro-algae sample. The elemental composition of the SyRM was regulated by the starting materials used for the synthesis. The SyRM was used as a comparative standard for non-destructive alpha-particle activation analysis of marine macro-alga samples. P, Cl, K and Ca were determined simultaneously without correction for alpha range due to difference in the elemental composition between the analytical samples and the comparative standard. (author) 19 refs.; 4 tabs

  12. Comparison of optimal design methods in inverse problems

    International Nuclear Information System (INIS)

    Banks, H T; Holm, K; Kappel, F

    2011-01-01

    Typical optimal design methods for inverse or parameter estimation problems are designed to choose optimal sampling distributions through minimization of a specific cost function related to the resulting error in parameter estimates. It is hoped that the inverse problem will produce parameter estimates with increased accuracy using data collected according to the optimal sampling distribution. Here we formulate the classical optimal design problem in the context of general optimization problems over distributions of sampling times. We present a new Prohorov metric-based theoretical framework that permits one to treat succinctly and rigorously any optimal design criteria based on the Fisher information matrix. A fundamental approximation theory is also included in this framework. A new optimal design, SE-optimal design (standard error optimal design), is then introduced in the context of this framework. We compare this new design criterion with the more traditional D-optimal and E-optimal designs. The optimal sampling distributions from each design are used to compute and compare standard errors; the standard errors for parameters are computed using asymptotic theory or bootstrapping and the optimal mesh. We use three examples to illustrate ideas: the Verhulst–Pearl logistic population model (Banks H T and Tran H T 2009 Mathematical and Experimental Modeling of Physical and Biological Processes (Boca Raton, FL: Chapman and Hall/CRC)), the standard harmonic oscillator model (Banks H T and Tran H T 2009) and a popular glucose regulation model (Bergman R N, Ider Y Z, Bowden C R and Cobelli C 1979 Am. J. Physiol. 236 E667–77; De Gaetano A and Arino O 2000 J. Math. Biol. 40 136–68; Toffolo G, Bergman R N, Finegood D T, Bowden C R and Cobelli C 1980 Diabetes 29 979–90)

  13. Comparison of optimal design methods in inverse problems

    Science.gov (United States)

    Banks, H. T.; Holm, K.; Kappel, F.

    2011-07-01

    Typical optimal design methods for inverse or parameter estimation problems are designed to choose optimal sampling distributions through minimization of a specific cost function related to the resulting error in parameter estimates. It is hoped that the inverse problem will produce parameter estimates with increased accuracy using data collected according to the optimal sampling distribution. Here we formulate the classical optimal design problem in the context of general optimization problems over distributions of sampling times. We present a new Prohorov metric-based theoretical framework that permits one to treat succinctly and rigorously any optimal design criteria based on the Fisher information matrix. A fundamental approximation theory is also included in this framework. A new optimal design, SE-optimal design (standard error optimal design), is then introduced in the context of this framework. We compare this new design criterion with the more traditional D-optimal and E-optimal designs. The optimal sampling distributions from each design are used to compute and compare standard errors; the standard errors for parameters are computed using asymptotic theory or bootstrapping and the optimal mesh. We use three examples to illustrate ideas: the Verhulst-Pearl logistic population model (Banks H T and Tran H T 2009 Mathematical and Experimental Modeling of Physical and Biological Processes (Boca Raton, FL: Chapman and Hall/CRC)), the standard harmonic oscillator model (Banks H T and Tran H T 2009) and a popular glucose regulation model (Bergman R N, Ider Y Z, Bowden C R and Cobelli C 1979 Am. J. Physiol. 236 E667-77 De Gaetano A and Arino O 2000 J. Math. Biol. 40 136-68 Toffolo G, Bergman R N, Finegood D T, Bowden C R and Cobelli C 1980 Diabetes 29 979-90).

  14. Iodine in different food articles and standard reference materials

    International Nuclear Information System (INIS)

    Dermelj, M.; Slejkovec, Z.; Byrne, A.R.; Stegnar, P.; Stibilj, V.; Rossbach, M.

    1990-01-01

    The greater part of essential iodine enters living organisms via the food chain. Nevertheless, quantitative data on its concentration in diets, food articles and also in available SRMs are very poor and scarce. This and WHO recommendations on daily allowances of iodine for man via food articles caused an added demand for accurate and reliable determination of iodine in these samples. From this point of view the purpose of the present was to analyse and to establish the concentration levels of total iodine in some food articles, diets, SRMs and candidate reference materials by the use of rapid radiochemical separation, developed in our laboratory. The results were checked by the analysis of SRMs with available certified values for iodine and good agreement is evident. (orig.)

  15. An optimized routing algorithm for the automated assembly of standard multimode ribbon fibers in a full-mesh optical backplane

    Science.gov (United States)

    Basile, Vito; Guadagno, Gianluca; Ferrario, Maddalena; Fassi, Irene

    2018-03-01

    In this paper a parametric, modular and scalable algorithm allowing a fully automated assembly of a backplane fiber-optic interconnection circuit is presented. This approach guarantees the optimization of the optical fiber routing inside the backplane with respect to specific criteria (i.e. bending power losses), addressing both transmission performance and overall costs issues. Graph theory has been exploited to simplify the complexity of the NxN full-mesh backplane interconnection topology, firstly, into N independent sub-circuits and then, recursively, into a limited number of loops easier to be generated. Afterwards, the proposed algorithm selects a set of geometrical and architectural parameters whose optimization allows to identify the optimal fiber optic routing for each sub-circuit of the backplane. The topological and numerical information provided by the algorithm are then exploited to control a robot which performs the automated assembly of the backplane sub-circuits. The proposed routing algorithm can be extended to any array architecture and number of connections thanks to its modularity and scalability. Finally, the algorithm has been exploited for the automated assembly of an 8x8 optical backplane realized with standard multimode (MM) 12-fiber ribbons.

  16. Global Reference Tables for Management Information Systems

    Data.gov (United States)

    Social Security Administration — This database is a collection of reference tables that store common information used throughout SSA. These tables standardize code structures and code usage of SSA...

  17. National Survey of Adult and Pediatric Reference Intervals in Clinical Laboratories across Canada: A Report of the CSCC Working Group on Reference Interval Harmonization.

    Science.gov (United States)

    Adeli, Khosrow; Higgins, Victoria; Seccombe, David; Collier, Christine P; Balion, Cynthia M; Cembrowski, George; Venner, Allison A; Shaw, Julie

    2017-11-01

    Reference intervals are widely used decision-making tools in laboratory medicine, serving as health-associated standards to interpret laboratory test results. Numerous studies have shown wide variation in reference intervals, even between laboratories using assays from the same manufacturer. Lack of consistency in either sample measurement or reference intervals across laboratories challenges the expectation of standardized patient care regardless of testing location. Here, we present data from a national survey conducted by the Canadian Society of Clinical Chemists (CSCC) Reference Interval Harmonization (hRI) Working Group that examines variation in laboratory reference sample measurements, as well as pediatric and adult reference intervals currently used in clinical practice across Canada. Data on reference intervals currently used by 37 laboratories were collected through a national survey to examine the variation in reference intervals for seven common laboratory tests. Additionally, 40 clinical laboratories participated in a baseline assessment by measuring six analytes in a reference sample. Of the seven analytes examined, alanine aminotransferase (ALT), alkaline phosphatase (ALP), and creatinine reference intervals were most variable. As expected, reference interval variation was more substantial in the pediatric population and varied between laboratories using the same instrumentation. Reference sample results differed between laboratories, particularly for ALT and free thyroxine (FT4). Reference interval variation was greater than test result variation for the majority of analytes. It is evident that there is a critical lack of harmonization in laboratory reference intervals, particularly for the pediatric population. Furthermore, the observed variation in reference intervals across instruments cannot be explained by the bias between the results obtained on instruments by different manufacturers. Copyright © 2017 The Canadian Society of Clinical Chemists

  18. Standard test method for determination of reference temperature, to, for ferritic steels in the transition range

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the determination of a reference temperature, To, which characterizes the fracture toughness of ferritic steels that experience onset of cleavage cracking at elastic, or elastic-plastic KJc instabilities, or both. The specific types of ferritic steels (3.2.1) covered are those with yield strengths ranging from 275 to 825 MPa (40 to 120 ksi) and weld metals, after stress-relief annealing, that have 10 % or less strength mismatch relative to that of the base metal. 1.2 The specimens covered are fatigue precracked single-edge notched bend bars, SE(B), and standard or disk-shaped compact tension specimens, C(T) or DC(T). A range of specimen sizes with proportional dimensions is recommended. The dimension on which the proportionality is based is specimen thickness. 1.3 Median KJc values tend to vary with the specimen type at a given test temperature, presumably due to constraint differences among the allowable test specimens in 1.2. The degree of KJc variability among specimen types i...

  19. Real-time SPARSE-SENSE cardiac cine MR imaging: optimization of image reconstruction and sequence validation.

    Science.gov (United States)

    Goebel, Juliane; Nensa, Felix; Bomas, Bettina; Schemuth, Haemi P; Maderwald, Stefan; Gratz, Marcel; Quick, Harald H; Schlosser, Thomas; Nassenstein, Kai

    2016-12-01

    Improved real-time cardiac magnetic resonance (CMR) sequences have currently been introduced, but so far only limited practical experience exists. This study aimed at image reconstruction optimization and clinical validation of a new highly accelerated real-time cine SPARSE-SENSE sequence. Left ventricular (LV) short-axis stacks of a real-time free-breathing SPARSE-SENSE sequence with high spatiotemporal resolution and of a standard segmented cine SSFP sequence were acquired at 1.5 T in 11 volunteers and 15 patients. To determine the optimal iterations, all volunteers' SPARSE-SENSE images were reconstructed using 10-200 iterations, and contrast ratios, image entropies, and reconstruction times were assessed. Subsequently, the patients' SPARSE-SENSE images were reconstructed with the clinically optimal iterations. LV volumetric values were evaluated and compared between both sequences. Sufficient image quality and acceptable reconstruction times were achieved when using 80 iterations. Bland-Altman plots and Passing-Bablok regression showed good agreement for all volumetric parameters. 80 iterations are recommended for iterative SPARSE-SENSE image reconstruction in clinical routine. Real-time cine SPARSE-SENSE yielded comparable volumetric results as the current standard SSFP sequence. Due to its intrinsic low image acquisition times, real-time cine SPARSE-SENSE imaging with iterative image reconstruction seems to be an attractive alternative for LV function analysis. • A highly accelerated real-time CMR sequence using SPARSE-SENSE was evaluated. • SPARSE-SENSE allows free breathing in real-time cardiac cine imaging. • For clinically optimal SPARSE-SENSE image reconstruction, 80 iterations are recommended. • Real-time SPARSE-SENSE imaging yielded comparable volumetric results as the reference SSFP sequence. • The fast SPARSE-SENSE sequence is an attractive alternative to standard SSFP sequences.

  20. Development and testing of standardized procedures and reference data for LWR surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.

    1979-02-01

    The resources and talents of many national and international organizations and laboratories, both governmental and industrial, are being used to establish analysis methods for predicting the embrittlement condition of light water reactor (LWR) primary systems. The exact interrelationships and responsibilities between those developing, understanding, combining, and applying state-of-the-art technology in dosimetry, metallurgy, and fracture mechanics for reactor systems analysis are being carefully reviewed and studied. This has resulted in a more comprehensive definition of the scope of new and updated ASTM standards required for the analysis and interpretation of LWR pressure vessel surveillance results. Fifteen new and updated ASTM standards have now been identified, together with a restructuring of the main interfaces between the individual standard practices, guides, and methods. The paper briefly discusses these standards and the initial results of multi-laboratory research work involved in their validation and calibration

  1. Optimizing integrated reference cases in the OCTAVIUS project

    DEFF Research Database (Denmark)

    Kvamsdal, Hanne M.; Ehlers, Sören; Kather, Alfons

    2016-01-01

    . This is important especially for the coal fired power plant, where integration of waste heat from the capture plant or the CO2 compressor intercoolers can lead to a significant increase in overall efficiency. The configuration of intercoolers for the CO2 compressor is adapted to achieve the highest overall...... the CESAR, CAESAR, and DECARBit projects, two reference power plants are modelled in Ebsilon®Professional. The first is an 800 MWe coal case, the second a 430 MWe natural gas combined cycle (NGCC) case. For each power plant two separate capture plants are considered: one using 30 wt% MEA as solvent system...... efficiency. For the natural gas combined cycle plant, integration is not that beneficial, since there is no heat sink available in the water steam cycle. In the end, the cost of electricity and cost of CO2 avoided is calculated for all four cases. While the CESAR1 solvent system in a conventional absorber...

  2. How do reference montage and electrodes setup affect the measured scalp EEG potentials?

    Science.gov (United States)

    Hu, Shiang; Lai, Yongxiu; Valdes-Sosa, Pedro A.; Bringas-Vega, Maria L.; Yao, Dezhong

    2018-04-01

    Objective. Human scalp electroencephalogram (EEG) is widely applied in cognitive neuroscience and clinical studies due to its non-invasiveness and ultra-high time resolution. However, the representativeness of the measured EEG potentials for the underneath neural activities is still a problem under debate. This study aims to investigate systematically how both reference montage and electrodes setup affect the accuracy of EEG potentials. Approach. First, the standard EEG potentials are generated by the forward calculation with a single dipole in the neural source space, for eleven channel numbers (10, 16, 21, 32, 64, 85, 96, 128, 129, 257, 335). Here, the reference is the ideal infinity implicitly determined by forward theory. Then, the standard EEG potentials are transformed to recordings with different references including five mono-polar references (Left earlobe, Fz, Pz, Oz, Cz), and three re-references (linked mastoids (LM), average reference (AR) and reference electrode standardization technique (REST)). Finally, the relative errors between the standard EEG potentials and the transformed ones are evaluated in terms of channel number, scalp regions, electrodes layout, dipole source position and orientation, as well as sensor noise and head model. Main results. Mono-polar reference recordings are usually of large distortions; thus, a re-reference after online mono-polar recording should be adopted in general to mitigate this effect. Among the three re-references, REST is generally superior to AR for all factors compared, and LM performs worst. REST is insensitive to head model perturbation. AR is subject to electrodes coverage and dipole orientation but no close relation with channel number. Significance. These results indicate that REST would be the first choice of re-reference and AR may be an alternative option for high level sensor noise case. Our findings may provide the helpful suggestions on how to obtain the EEG potentials as accurately as possible for

  3. Sunlit Uplands: The Genius of the NICE Reference Case

    Directory of Open Access Journals (Sweden)

    Paul C Langley

    2016-07-01

    Full Text Available The NICE reference case has received widespread acceptance in health technology assessment. The lifetime cost-per-QALY model and constructed claims for product impact have been widely emulated in country-specific guidelines for formulary submission as well as in publications in the leading health technology journals. Unfortunately, from the perspective of the standards of normal science, adherence to the reference case standard means that the claims made are typically non-evaluable. They have to be taken at face value. They may suggest potential evaluable hypotheses for clinical and cost-effectiveness claims, but there is no requirement in the reference case for claims to be put in an evaluable form and for manufacturers to suggest possible protocols for product impact assessment. This is not an acceptable situation. Absent the standards for falsification and replication, which are at the core of the scientific method, we have no idea whether the claims accepted by NICE are right or even if they are wrong. If we accept the reference case paradigm should we conclude that the sunlit uplands of formulary decisions based on non-evaluable simulated claims for cost-effectiveness has been reached? Have we rejected natural selection in favor of intelligent design? Conflict of Interest None Type: Commentary

  4. Topology optimization of inertia driven dosing units

    DEFF Research Database (Denmark)

    Andreasen, Casper Schousboe

    2017-01-01

    This paper presents a methodology for optimizing inertia driven dosing units, sometimes referred to as eductors, for use in small scale flow applications. The unit is assumed to operate at low to moderate Reynolds numbers and under steady state conditions. By applying topology optimization...

  5. A novel approach for optimal chiller loading using particle swarm optimization

    Energy Technology Data Exchange (ETDEWEB)

    Ardakani, A. Jahanbani; Ardakani, F. Fattahi; Hosseinian, S.H. [Department of Electrical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Hafez Avenue, Tehran 15875-4413 (Iran, Islamic Republic of)

    2008-07-01

    This study employs two new methods to solve optimal chiller loading (OCL) problem. These methods are continuous genetic algorithm (GA) and particle swarm optimization (PSO). Because of continuous nature of variables in OCL problem, continuous GA and PSO easily overcome deficiencies in other conventional optimization methods. Partial load ratio (PLR) of the chiller is chosen as the variable to be optimized and consumption power of the chiller is considered as fitness function. Both of these methods find the optimal solution while the equality constraint is exactly satisfied. Some of the major advantages of proposed approaches over other conventional methods can be mentioned as fast convergence, escaping from getting into local optima, simple implementation as well as independency of the solution from the problem. Abilities of proposed methods are examined with reference to an example system. To demonstrate these abilities, results are compared with binary genetic algorithm method. The proposed approaches can be perfectly applied to air-conditioning systems. (author)

  6. Shielding standards: a case history

    International Nuclear Information System (INIS)

    Battat, M.E.

    1977-01-01

    A discussion of the sequence of events leading from the inception of a standard to its transmittal to the ANSI Board of Standards Review will be given. The standard referred to is entitled, ''Neutron and Gamma-Ray Flux-to-Dose-Rate Factors,'' (ANSI N666). Certain questions raised during the review process and the compatibility of this standard with the USA Code of Federal Regulations will be discussed

  7. The reference individual of radiation protection

    International Nuclear Information System (INIS)

    Eckerman, K.F.; Cristy, M.

    1995-01-01

    The 70-kg open-quotes standard manclose quotes representing a typical Western adult male has been used in physiological models since at least the 1920s. In 1949 at the Chalk River conference, health physicists from the U.S., UK, and Canada agreed on the concept of a standard man to facilitate comparison of internal dose estimates. The 70-kg standard man included specifications of the masses of 25 organs and tissues, total body content of 15 elements, total water intake and output, water content of the body, and some anatomical and physiological data for the respiratory and gastrointestinal tracts. In 1959, in its Publication 2 2 on permissible doses for internal radiation the International Commission on Radiological Protection (ICRP) modified standard man. In 1963 the ICRP established a task group to revise and extend the standard man concept. The name was changed later to Reference Man and the task group's work was published in 1975 as ICRP Publication 23 3 . Publication 23 similar to Publication 2, updates and documents the sources of the data. Data on women, children, and fetuses were also collected, where available, but these data were limited primarily to anatomical data and only a few reference values were established for these groups. Information assembled during the course of the effort on the Reference Man report was used at Oak Ridge National Laboratory (ORNL) to construct a mathematical representation of the body (a phantom) that was suitable for use with Monte Carlo methods in the calculation of organ doses. That effort was undertaken to improve estimates of dose from photon-emitting radionuclides residing within organs, so-called internal emitters. The phantom, although updated throughout the years, remains today as the basis for organ dose estimates in nuclear medicine and radiation protection and underlies the radiation risk data derived from the epidemiologic studies of the atomic bomb survivors of Hiroshima and Nagasaki

  8. Optimization of instrumental neutron activation analysis method by means of 2k experimental design technique aiming the validation of analytical procedures

    International Nuclear Information System (INIS)

    Petroni, Robson; Moreira, Edson G.

    2013-01-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) methods were carried out for the determination of the elements arsenic, chromium, cobalt, iron, rubidium, scandium, selenium and zinc in biological materials. The aim is to validate the analytical methods for future accreditation at the National Institute of Metrology, Quality and Technology (INMETRO). The 2 k experimental design was applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. Samples of Mussel Tissue Certified Reference Material and multi-element standards were analyzed considering the following variables: sample decay time, counting time and sample distance to detector. The standard multi-element concentration (comparator standard), mass of the sample and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN - CNEN/SP). Optimized conditions were estimated based on the results of z-score tests, main effect and interaction effects. The results obtained with the different experimental configurations were evaluated for accuracy (precision and trueness) for each measurement. (author)

  9. Selected Reference Books of 1998.

    Science.gov (United States)

    McIlvaine, Eileen

    1999-01-01

    Reviews a selection of recent scholarly and general reference works under the categories of Periodicals and Newspapers, Philosophy, Literature, Film and Radio, Art and Architecture, Music, Political Science, Women's Studies, and History. A brief summary of new editions of standard works is provided at the end of the articles. (AEF)

  10. Preparation standardisation and use of plutonium nitrate reference solutions

    International Nuclear Information System (INIS)

    Brown, M.L.; Drummond, J.L.

    1981-07-01

    A procedure is described for the purification of a plutonium nitrate solution in nitric acid for use as a plutonium master standard. Anion exchange chromatography followed by oxalate precipitation is used to purify the plutonium and the residual cationic impurities are analysed by emission spectroscopy. The plutonium content is accurately and precisely measured by two independent methods, namely by gravimetry as PuO 2 at 1250 0 C and by ceric oxidation, ferrous reduction and dichromate titration. Full details of the purification procedure are given, with recommended methods for storing and using the standard solution. It is concluded that such a solution is the most satisfactory reference material, available for plutonium analysis for reprocessing plants, and is adequately related to other, internationally accepted, standard reference materials. (author)

  11. Biological reference materials and analysis of toxic elements

    Energy Technology Data Exchange (ETDEWEB)

    Subramanian, R; Sukumar, A

    1988-12-01

    Biological monitoring of toxic metal pollution in the environment requires quality control analysis with use of standard reference materials. A variety of biological tissues are increasingly used for analysis of element bioaccumulation, but the available Certified Reference Materials (CRMs) are insufficient. An attempt is made to review the studies made using biological reference materials for animal and human tissues. The need to have inter-laboratory studies and CRM in the field of biological monitoring of toxic metals is also discussed.

  12. Topology Optimization

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt; Damkilde, Lars

    2007-01-01

    . A way to solve the initial design problem namely finding a form can be solved by so-called topology optimization. The idea is to define a design region and an amount of material. The loads and supports are also fidefined, and the algorithm finds the optimal material distribution. The objective function...... dictates the form, and the designer can choose e.g. maximum stiness, maximum allowable stresses or maximum lowest eigenfrequency. The result of the topology optimization is a relatively coarse map of material layout. This design can be transferred to a CAD system and given the necessary geometrically...... refinements, and then remeshed and reanalysed in other to secure that the design requirements are met correctly. The output of standard topology optimization has seldom well-defined, sharp contours leaving the designer with a tedious interpretation, which often results in less optimal structures. In the paper...

  13. 239Pu standards for quantitative neutron-induced autoradiography

    International Nuclear Information System (INIS)

    Smith, J.M.; Atherton, D.R.; Wronski, T.J.; Jee, W.S.S.

    1977-01-01

    The present study deals with the preparation of 239 Pu standards for neutron bone tissue autoradiography and the calibration of these standards with respect to uranium reference standards. Known concentrations of 239 Pu were prepared in methyl methacrylate and Bioplastic casting resin bars. Wafers sawed from these bars served as standards. Solid state nuclear tract detectors (Lexan polycarbonate) were used to record fission fragment tracks after the standards were exposed to a thermal neutron flux. The original bars were found to contain a uniform distribution of 239 Pu. To confirm the concentration of 239 Pu in the wafers, the induced track density from the 239 Pu standards was compared with that from uranium reference standards. The average fission fragment detection efficiency for all of the standards was 0.51

  14. Refractive outcomes of an advanced aspherically optimized profile for myopia corrections by LASIK: a retrospective comparison with the standard aspherically optimized profile

    Directory of Open Access Journals (Sweden)

    Meyer B

    2015-02-01

    Full Text Available Bertram Meyer,1 Georg Sluyterman van Langeweyde,2 Matthias Wottke2 1Augencentrum Köln, Cologne, Germany; 2Carl Zeiss Meditec AG, Jena, Germany Purpose: A retrospective comparison of refractive outcomes of a new, aspherically optimized profile with an enhanced energy correction feature (Triple-A and the conventionally used aspherically optimized profile (ASA, or aberration smart ablation for correction of low-to-high myopia.Setting: Augen-OP-Centrum, Cologne, GermanyDesign: Retrospective nonrandomized comparative studyMethods: A central database at the Augen-OP-Centrum was used to gather retrospective data for low-to-high myopia (up to -10 D. One hundred and seven eyes (56 patients were treated with the ASA profile, and 79 eyes (46 patients were treated with the Triple-A profile. Postoperative outcomes were evaluated at 1 month, 3 months, 6 months, and 1 year follow-up time points.Results: The Triple-A profile showed better predictability indicated by a significantly lower standard deviation of residuals (0.32–0.34 vs 0.36–0.44, Triple-A vs ASA in the 6-month to 1-year period. The Triple-A group had better stability across all time intervals and achieved better postoperative astigmatism improvements with significantly lower scatter. This group achieved better safety at 1 year, with 100% of eyes showing no change or gain in Snellen lines, compared with 97% in the ASA group. A better safety index was observed for the Triple-A group at later time points. The Triple-A group had a better efficacy index and a higher percentage of eyes with an uncorrected Snellen visual acuity of 20/20 or greater at all investigated follow-up time points.Conclusion: The new aspherically optimized Triple-A profile can safely and effectively correct low-to-high myopia. It has demonstrated superiority over the ASA profile in most refractive outcomes. Keywords: Triple-A, wavefront measurements, corneal aberrations, corneal asphericity, ablation profile

  15. Establishment of local Diagnostic Reference Levels (DRLs) for ...

    African Journals Online (AJOL)

    Diagnostic reference levels (DRLs) is an essential optimization tool in radiography and radiological sciences. The objective of the study is to establish DRL for radiography examinations in north eastern Nigeria. A Prospective cross- sectional study conducted in two university teaching hospitals in north eastern Nigeria.

  16. Accurate determination of brain metabolite concentrations using ERETIC as external reference.

    Science.gov (United States)

    Zoelch, Niklaus; Hock, Andreas; Heinzer-Schweizer, Susanne; Avdievitch, Nikolai; Henning, Anke

    2017-08-01

    Magnetic Resonance Spectroscopy (MRS) can provide in vivo metabolite concentrations in standard concentration units if a reliable reference signal is available. For 1 H MRS in the human brain, typically the signal from the tissue water is used as the (internal) reference signal. However, a concentration determination based on the tissue water signal most often requires a reliable estimate of the water concentration present in the investigated tissue. Especially in clinically interesting cases, this estimation might be difficult. To avoid assumptions about the water in the investigated tissue, the Electric REference To access In vivo Concentrations (ERETIC) method has been proposed. In this approach, the metabolite signal is compared with a reference signal acquired in a phantom and potential coil-loading differences are corrected using a synthetic reference signal. The aim of this study, conducted with a transceiver quadrature head coil, was to increase the accuracy of the ERETIC method by correcting the influence of spatial B 1 inhomogeneities and to simplify the quantification with ERETIC by incorporating an automatic phase correction for the ERETIC signal. Transmit field ( B1+) differences are minimized with a volume-selective power optimization, whereas reception sensitivity changes are corrected using contrast-minimized images of the brain and by adapting the voxel location in the phantom measurement closely to the position measured in vivo. By applying the proposed B 1 correction scheme, the mean metabolite concentrations determined with ERETIC in 21 healthy subjects at three different positions agree with concentrations derived with the tissue water signal as reference. In addition, brain water concentrations determined with ERETIC were in agreement with estimations derived using tissue segmentation and literature values for relative water densities. Based on the results, the ERETIC method presented here is a valid tool to derive in vivo metabolite

  17. Reference Gene Screening for Analyzing Gene Expression Across Goat Tissue

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    2013-12-01

    Full Text Available Real-time quantitative PCR (qRT-PCR is one of the important methods for investigating the changes in mRNA expression levels in cells and tissues. Selection of the proper reference genes is very important when calibrating the results of real-time quantitative PCR. Studies on the selection of reference genes in goat tissues are limited, despite the economic importance of their meat and dairy products. We used real-time quantitative PCR to detect the expression levels of eight reference gene candidates (18S, TBP, HMBS, YWHAZ, ACTB, HPRT1, GAPDH and EEF1A2 in ten tissues types sourced from Boer goats. The optimal reference gene combination was selected according to the results determined by geNorm, NormFinder and Bestkeeper software packages. The analyses showed that tissue is an important variability factor in genes expression stability. When all tissues were considered, 18S, TBP and HMBS is the optimal reference combination for calibrating quantitative PCR analysis of gene expression from goat tissues. Dividing data set by tissues, ACTB was the most stable in stomach, small intestine and ovary, 18S in heart and spleen, HMBS in uterus and lung, TBP in liver, HPRT1 in kidney and GAPDH in muscle. Overall, this study provided valuable information about the goat reference genes that can be used in order to perform a proper normalisation when relative quantification by qRT-PCR studies is undertaken.

  18. Following an Optimal Batch Bioreactor Operations Model

    DEFF Research Database (Denmark)

    Ibarra-Junquera, V.; Jørgensen, Sten Bay; Virgen-Ortíz, J.J.

    2012-01-01

    The problem of following an optimal batch operation model for a bioreactor in the presence of uncertainties is studied. The optimal batch bioreactor operation model (OBBOM) refers to the bioreactor trajectory for nominal cultivation to be optimal. A multiple-variable dynamic optimization of fed...... as the master system which includes the optimal cultivation trajectory for the feed flow rate and the substrate concentration. The “real” bioreactor, the one with unknown dynamics and perturbations, is considered as the slave system. Finally, the controller is designed such that the real bioreactor...

  19. South African address standard and initiatives towards an international address standard

    CSIR Research Space (South Africa)

    Cooper, Antony K

    2008-10-01

    Full Text Available ; visiting friends; and providing a reference context for presenting other information. The benefits of an international address standards include: enabling address interoperability across boundaries; reducing service delivery costs; enabling development...

  20. Development of Radiation-hard Bandgap Reference and Temperature Sensor in CMOS 130 nm Technology

    CERN Document Server

    Kuczynska, Marika; Bugiel, Szymon; Firlej, Miroslaw; Fiutowski, Tomasz; Idzik, Marek; Michelis, Stefano; Moron, Jakub; Przyborowski, Dominik; Swientek, Krzysztof

    2015-01-01

    A stable reference voltage (or current) source is a standard component of today's microelectronics systems. In particle physics experiments such reference is needed in spite of harsh ionizing radiation conditions, i.e. doses exceeding 100 Mrads and fluences above 1e15 n/cm2. After such radiation load a bandgap reference using standard p-n junction of bipolar transistor does not work properly. Instead of using standard p-n junctions, two enclosed layout transistor (ELTMOS) structures are used to create radiation-hard diodes: the ELT bulk diode and the diode obtained using the ELTMOS as dynamic threshold transistor (DTMOS). In this paper we have described several sub-1V references based on ELTMOS bulk diode and DTMOS based diode, using CMOS 130 nm process. Voltage references the structures with additional PTAT (Proportional To Absolute Temperature) output for temperature measurements were also designed. We present and compare post-layout simulations of the developed bandgap references and temperature sensors, w...