WorldWideScience

Sample records for optical techniques

  1. Emerging optical nanoscopy techniques

    Directory of Open Access Journals (Sweden)

    Montgomery PC

    2015-09-01

    Full Text Available Paul C Montgomery, Audrey Leong-Hoi Laboratoire des Sciences de l'Ingénieur, de l'Informatique et de l'Imagerie (ICube, Unistra-CNRS, Strasbourg, France Abstract: To face the challenges of modern health care, new imaging techniques with subcellular resolution or detection over wide fields are required. Far field optical nanoscopy presents many new solutions, providing high resolution or detection at high speed. We present a new classification scheme to help appreciate the growing number of optical nanoscopy techniques. We underline an important distinction between superresolution techniques that provide improved resolving power and nanodetection techniques for characterizing unresolved nanostructures. Some of the emerging techniques within these two categories are highlighted with applications in biophysics and medicine. Recent techniques employing wider angle imaging by digital holography and scattering lens microscopy allow superresolution to be achieved for subcellular and even in vivo, imaging without labeling. Nanodetection techniques are divided into four subcategories using contrast, phase, deconvolution, and nanomarkers. Contrast enhancement is illustrated by means of a polarized light-based technique and with strobed phase-contrast microscopy to reveal nanostructures. Very high sensitivity phase measurement using interference microscopy is shown to provide nanometric surface roughness measurement or to reveal internal nanometric structures. Finally, the use of nanomarkers is illustrated with stochastic fluorescence microscopy for mapping intracellular structures. We also present some of the future perspectives of optical nanoscopy. Keywords: microscopy, imaging, superresolution, nanodetection, biophysics, medical imaging

  2. Emerging optical nanoscopy techniques

    Science.gov (United States)

    Montgomery, Paul C; Leong-Hoi, Audrey

    2015-01-01

    To face the challenges of modern health care, new imaging techniques with subcellular resolution or detection over wide fields are required. Far field optical nanoscopy presents many new solutions, providing high resolution or detection at high speed. We present a new classification scheme to help appreciate the growing number of optical nanoscopy techniques. We underline an important distinction between superresolution techniques that provide improved resolving power and nanodetection techniques for characterizing unresolved nanostructures. Some of the emerging techniques within these two categories are highlighted with applications in biophysics and medicine. Recent techniques employing wider angle imaging by digital holography and scattering lens microscopy allow superresolution to be achieved for subcellular and even in vivo, imaging without labeling. Nanodetection techniques are divided into four subcategories using contrast, phase, deconvolution, and nanomarkers. Contrast enhancement is illustrated by means of a polarized light-based technique and with strobed phase-contrast microscopy to reveal nanostructures. Very high sensitivity phase measurement using interference microscopy is shown to provide nanometric surface roughness measurement or to reveal internal nanometric structures. Finally, the use of nanomarkers is illustrated with stochastic fluorescence microscopy for mapping intracellular structures. We also present some of the future perspectives of optical nanoscopy. PMID:26491270

  3. Optical techniques in optogenetics

    Science.gov (United States)

    Mohanty, Samarendra K.; Lakshminarayananan, Vasudevan

    2015-07-01

    Optogenetics is an innovative technique for optical control of cells. This field has exploded over the past decade or so and has given rise to great advances in neuroscience. A variety of applications both from the basic and applied research have emerged, turning the early ideas into a powerful paradigm for cell biology, neuroscience, and medical research. This review aims at highlighting the basic concepts that are essential for a comprehensive understanding of optogenetics and some important biological/biomedical applications. Further, emphasis is placed on advancement in optogenetics-associated light-based methods for controlling gene expression, spatially controlled optogenetic stimulation and detection of cellular activities.

  4. Optical techniques in regenerative medicine

    CERN Document Server

    Morgan, Stephen P

    2013-01-01

    In regenerative medicine, tissue engineers largely rely on destructive and time-consuming techniques that do not allow in situ and spatial monitoring of tissue growth. Furthermore, once the therapy is implanted in the patient, clinicians are often unable to monitor what is happening in the body. To tackle these barriers, optical techniques have been developed to image and characterize many tissue properties, fabricate tissue engineering scaffolds, and characterize the properties of the scaffolds. Optical Techniques in Regenerative Medicine illustrates how to use optical imaging techniques and

  5. Optical pulses, lasers, measuring techniques

    CERN Document Server

    Früngel, Frank B A

    1965-01-01

    High Speed Pulse Technology: Volume II: Optical Pulses - Lasers - Measuring Techniques focuses on the theoretical and engineering problems that result from the capacitor discharge technique.This book is organized into three main topics: light flash production from a capacitive energy storage; signal transmission and ranging systems by capacitor discharges and lasers; and impulse measuring technique. This text specifically discusses the air spark under atmospheric conditions, industrial equipment for laser flashing, and claims for light transmitting system. The application of light impulse sign

  6. Environmental monitoring using optical techniques

    Science.gov (United States)

    Svanberg, Sune

    2003-11-01

    An overview of optical techniques for environmental monitoring is presented. Range-resolved measurements of atmospheric pollutants can be performed using the differential absorption lidar technique. Fluorescence lidar allows assessment of vegetation status and also the conditions of the facades of historical buildings. Diode lasers provide particularly realistic schemes for atmospheric gas analysis, where certain wavelength ranges, which are not easily directly assessed, can be reached by sum- and difference frequency generation. Finally, the gas correlation principle can be used for real-time imaging of hydrocarbons. Several types of such optical environmental monitoring are illustrated with examples from research at the Lund Institute of Technology, Sweden.

  7. Cognitive optical networks: architectures and techniques

    Science.gov (United States)

    Grebeshkov, Alexander Y.

    2017-04-01

    This article analyzes architectures and techniques of the optical networks with taking into account the cognitive methodology based on continuous cycle "Observe-Orient-Plan-Decide-Act-Learn" and the ability of the cognitive systems adjust itself through an adaptive process by responding to new changes in the environment. Cognitive optical network architecture includes cognitive control layer with knowledge base for control of software-configurable devices as reconfigurable optical add-drop multiplexers, flexible optical transceivers, software-defined receivers. Some techniques for cognitive optical networks as flexible-grid technology, broker-oriented technique, machine learning are examined. Software defined optical network and integration of wireless and optical networks with radio over fiber technique and fiber-wireless technique in the context of cognitive technologies are discussed.

  8. Resolution enhancement techniques in optical lithography

    CERN Document Server

    Wong, Alfred K

    2001-01-01

    Ever-smaller IC devices are pushing the optical lithography envelope, increasing the importance of resolution enhancement techniques. This tutorial encompasses two decades of research. It discusses theoretical and practical aspects of commonly used techniques, including optical imaging and resolution, modified illumination, optical proximity correction, alternating and attenuating phase-shifting masks, selecting RETs, and second-generation RETs. Useful for students and practicing lithographers.

  9. All-optical signal processing technique for secure optical communication

    Science.gov (United States)

    Qian, Feng-chen; Su, Bing; Ye, Ya-lin; Zhang, Qian; Lin, Shao-feng; Duan, Tao; Duan, Jie

    2015-10-01

    Secure optical communication technologies are important means to solve the physical layer security for optical network. We present a scheme of secure optical communication system by all-optical signal processing technique. The scheme consists of three parts, as all-optical signal processing unit, optical key sequence generator, and synchronous control unit. In the paper, all-optical signal processing method is key technology using all-optical exclusive disjunction (XOR) gate based on optical cross-gain modulation effect, has advantages of wide dynamic range of input optical signal, simple structure and so on. All-optical XOR gate composed of two semiconductor optical amplifiers (SOA) is a symmetrical structure. By controlling injection current, input signal power, delay and filter bandwidth, the extinction ratio of XOR can be greater than 8dB. Finally, some performance parameters are calculated and the results are analyzed. The simulation and experimental results show that the proposed method can be achieved over 10Gbps optical signal encryption and decryption, which is simple, easy to implement, and error-free diffusion.

  10. Optical metrology techniques for dimensional stability measurements

    NARCIS (Netherlands)

    Ellis, Jonathan David

    2010-01-01

    This thesis work is optical metrology techniques to determine material stability. In addition to displacement interferometry, topics such as periodic nonlinearity, Fabry-Perot interferometry, refractometry, and laser stabilization are covered.

  11. Optical metrology techniques for dimensional stability measurements

    NARCIS (Netherlands)

    Ellis, Jonathan David

    2010-01-01

    This thesis work is optical metrology techniques to determine material stability. In addition to displacement interferometry, topics such as periodic nonlinearity, Fabry-Perot interferometry, refractometry, and laser stabilization are covered.

  12. Performance Monitoring Techniques Supporting Cognitive Optical Networking

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Borkowski, Robert; Zibar, Darko

    2013-01-01

    to solve this issue by realizing a network that can observe, act, learn and optimize its performance, taking into account end-to-end goals. In this letter we present the approach of cognition applied to heterogeneous optical networks developed in the framework of the EU project CHRON: Cognitive...... Heterogeneous Reconfigurable Optical Network. We focus on the approaches developed in the project for optical performance monitoring, which enable the feedback from the physical layer to the cognitive decision system by providing accurate description of the performance of the established lightpaths.......High degree of heterogeneity of future optical networks, such as services with different quality-of-transmission requirements, modulation formats and switching techniques, will pose a challenge for the control and optimization of different parameters. Incorporation of cognitive techniques can help...

  13. Optical measurement techniques - A push for digitization

    Science.gov (United States)

    Kulkarni, Rishikesh; Rastogi, Pramod

    2016-12-01

    Over the years, optical measurement techniques have been the problem-solving backbone of many engineering applications such as nondestructive testing of materials, measurement of various material properties, structural analysis and experimental mechanics [1-3]. Probably the most important advantage associated with any optical measurement system over other systems is its non-contact type of measurement capability. Apart from their non-contact nature, the optical measurement systems are capable of providing full-field measurements at scales ranging from milli-meters to nano-meters.

  14. Combining calcium imaging with other optical techniques.

    Science.gov (United States)

    Canepari, Marco; Zecevic, Dejan; Vogt, Kaspar E; Ogden, David; De Waard, Michel

    2013-12-01

    Ca(2+) imaging is a commonly used approach for measuring Ca(2+) signals at high spatial resolution. The method is often combined with electrode recordings to correlate electrical and chemical signals or to investigate Ca(2+) signals following an electrical stimulation. To obtain information on electrical activity at the same spatial resolution, Ca(2+) imaging must be combined with membrane potential imaging. Similarly, stimulation of subcellular compartments requires photostimulation. Thus, combining Ca(2+) imaging with an additional optical technique facilitates the study of a number of physiological questions. The aim of this article is to introduce some basic principles regarding the combination of Ca(2+) imaging with other optical techniques. We discuss the design of the optics, the design of experimental protocols, the optical characteristics of Ca(2+) indicators used in combination with an optical probe, and the affinity of the Ca(2+) indicator in relation to the type of measurement. This information will enable the reader to devise an optimal strategy for combined optical experiments.

  15. Dental diagnostics using optical coherence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nathel, H. [Lawrence Livermore National Lab., CA (United States); Colston, B. [Univ. of California, San Francisco, CA (United States); Armitage, G. [Univ. of California, Davis, CA (United States)] [and others

    1994-11-15

    Optical radiation can be used for diagnostic purposes in oral medicine. However, due to the turbid, amorphous, and inhomogeneous nature of dental tissue conventional techniques used to transilluminate materials are not well suited to dental tissues. Optical coherence techniques either in the time- of frequency-domain offer the capabilities of discriminating scattered from unscattered light, thus allowing for imaging through turbid tissue. Currently, using optical time-domain reflectometry we are able to discriminate specular from diffuse reflections occurring at tissue boundaries. We have determined the specular reflectivity of enamel and dentin to be approximately 6.6 x 10{sup -5} and 1.3 x 10{sup -6}, respectively. Implications to periodontal imaging will be discussed.

  16. Electro-optical techniques for signal conditioning

    Science.gov (United States)

    Helfrich, R. W.

    1981-01-01

    Electro-optical (EO) processing is discussed as a potential alternative to the all-digital approach to signal processing. Nonuniformity compensation can be done by normalizing all the single element detectors outputs in a staring array for both gain and level. Distortion correction can be accomplished with blackbodies, scene statistics or defocused optics. An algorithm used in digital signal conditioning that can be closely approximated by EO techniques is Local Area Brightness Control (LABC). In a digital processor, LABC is performed on a pixel-by-pixel basis, resulting in an enormous amount of calculation. A partially defocused optical system can be used in an EO analog to the digital system. For both nonuniformity compensation and LABC, the EO technique can result in great simplification.

  17. Optical Management Techniques for Organic Solar Cells

    CERN Document Server

    Rajagopal, Adharsh

    2016-01-01

    In this thesis, two different optical management techniques for organics based solar cells are explored. The first part is focused on the development of a textured rear reflector for OPVs. The use of textured reflector (TR) facilitates an increase in the optical path length along with light trapping within the active layer. TR was fabricated through a relatively simpler technique by depositing metal films over a microlens array (MLA). Zinc oxide nanoparticles were used to minimize the shadowing effect. Using TR, enhancements in short-circuit current density and power conversion efficiencies up to 10-25% were demonstrated for a polymer based organic solar cell. The second part is focused on improving the effectiveness of MLA incorporation in OPVs. The increase in path length achieved using MLA can be improved by increasing the refractive index of MLA and incorporating MLA directly on the transparent electrode instead of glass substrate. This approach could avoid the optical losses occurring at the interface be...

  18. Perspective of remote optical measurement techniques

    OpenAIRE

    Gregorio, Eduard; Rocadenbosch Burillo, Francisco

    2007-01-01

    This article presents an intercomparison between four different ROMTs: differential optical absorption spectroscopy (DOAS), differential absorption LIDAR (DIAL), Fourier transform infrared spectroscopy (FTIR), and tunable diode laser absorption spectroscopy (TDLAS). The main focus is on the TDLAS technique, where the main laser-diode typologies and modulation schemes, namely, wavelength modulation spectroscopy (WMS) and frequency modulation spectroscopy (FMS), are reviewed. At present, new pr...

  19. Scanning Techniques For Optical Data Storage

    Science.gov (United States)

    Towner, David K.

    1987-01-01

    It seems almost paradoxical that beams of light can be moved and steered at very high speeds using a variety of scanning methods, yet the optical disk drives now being designed and marketed for data storage applications have comparatively long access times. Knowing that optical data storage has unrealized potential is of interest, but of more immediate concern is the recognition that poor access performance is a serious design issue. Magnetic disk drives offer average seek times in the 15-25ms range, compared to about 80-500ms (or more, for CD ROMS) for current optical drives. This performance disparity exists, in part, because the relatively massive "optical heads" in use today cannot be transported across the radius of a disk as quickly as a stack of much lighter magnetic heads. Any potential distance advantage that the optical drive might have, due to its substantially higher track density, is offset by the magnetic drive's use of a multi-disk stack. As a result, the drive must achieve similar radial accelerations during seeks if it is to have similar average access times. The inability of current optical drives to approach the access speeds of comparable magnetic drives significantly reduces the competitiveness of optical products in major segments of the very large data storage market. This shortcoming is especially disturbing when we know that opto-mechanical scanners typically operate in the 1-10ms range and that non-mechanical scanning techniques can be substantially faster than that.

  20. New optical technique for bulk magnetostriction measurement

    CERN Document Server

    Samata, H; Uchida, T; Abe, S

    2000-01-01

    A new optical technique was applied to the measurement of magnetostriction in bulk samples. This technique utilizes an optical fiber bundle, AC-modulated light and lock-in detection. Deformation of the sample is determined from the ratio of the incident and reflected light intensities. Noise due to the instability of the light source is eliminated by obtaining the ratio of the incident and reflected light intensities, and the noise caused in the detector circuit can be reduced by lock-in detection. The performance of this method was characterized with a series of measurements using a gold film and crystal disks of pure iron and nickel. This technique offers a resolution of 0.5 nm and is sensitive enough to measure magnetostriction as small as 5x10 sup - sup 7 in 1 mm thick samples.

  1. Optical and digital techniques for information security

    CERN Document Server

    2005-01-01

    Optical and Digital Techniques for Information Security is the first book in a series focusing on Advanced Sciences and Technologies for Security Applications. This book encompases the results of research investigation and technologies used to secure, verify, recognize, track, and authenticate objects and information from theft, counterfeiting, and manipulation by unauthorized persons and agencies. This Information Security book will draw on the diverse expertise in optical sciences and engineering, digital image processing, imaging systems, information processing, computer based information systems, sensors, detectors, and biometrics to report innovative technologies that can be applied to information security issues. The Advanced Sciences and Technologies for Security Applications series focuses on research monographs in the areas of: -Recognition and identification (including optical imaging, biometrics, authentication, verification, and smart surveillance systems) -Biological and chemical threat detection...

  2. Surface Wear Measurement Using Optical Correlation Technique

    Science.gov (United States)

    Acinger, Kresimir

    1983-12-01

    The coherent optical correlation technique was applied for measuring the surface wear of a tappet (part of car engine), worn by friction with the camshaft. It was found that maximum correlation intensity decays exponentially with the number of wear cycles (i.e. camshaft revolutions). Tappets of the same make have an identical rate of correlation decay. Tappets of different makes have different rates of correlation decay which are in agreement with observed long term wear.

  3. Computational Techniques for LED Optical Microcavities

    OpenAIRE

    García Santiago, Xavier

    2015-01-01

    The project consist on the development of numerical methods and computational techniques to model the processes of light extraction in power LED (Light-Emitting Diodes) devices. We aim at the use of complex corrugated microstructures to boost the efficiency of our current LUXEON LED products. In order to study extraction efficiency in these devices a 3D optics model of thin film micro-structures must be developed and tested. In this project we develop a numerical model for computing and st...

  4. Polishing techniques for MEGARA pupil elements optics

    Science.gov (United States)

    Izazaga, R.; Carrasco, E.; Aguirre, D.; Salas, A.; Gil de Paz, A.; Gallego, J.; Iglesias, J.; Arroyo, J. M.; Hernández, M.; López, N.; López, V.; Quechol, J. T.; Salazar, M. F.; Carballo, C.; Cruz, E.; Arriaga, J.; De la Luz, J. A.; Huepa, A.; Jaimes, G. L.; Reyes, J.

    2016-07-01

    MEGARA (Multi-Espectrógrafo en GTC de Alta Resolución para Astronomía) is the new integral-field and multi-object optical spectrograph for the 10.4m Gran Telescopio Canarias.. It will offer RFWHM 6,000, 12,000 and 18,700 for the low- , mid- and high-resolution, respectively in the wavelength range 3650-9700Å. .The dispersive elements are volume phase holographic (VPH) gratings, sandwiched between two flat Fused Silica windows of high optical precision in large apertures. The design, based in VPHs in combination with Ohara PBM2Y prisms allows to keep the collimator and camera angle fixed. Seventy three optical elements are being built in Mexico at INAOE and CIO. For the low resolution modes, the VPHs windows specifications in irregularity is 1 fringe in 210mm x 170mm and 0.5 fringe in 190mm x 160mm. for a window thickness of 25 mm. For the medium and high resolution modes the irregularity specification is 2 fringes in 220mm x 180mm and 1 fringe in 205mm x 160mm, for a window thickness of 20mm. In this work we present a description of the polishing techniques developed at INAOE optical workshop to fabricate the 36 Fused Silica windows and 24 PBM2Y prisms that allows us to achieve such demanding specifications. We include the processes of mounting, cutting, blocking, polishing and testing.

  5. Optical multichannel analyzer techniques for high resolution optical spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chao, J.L.

    1980-06-01

    The development of optical multichannel analyzer techniques for UV/VIS spectroscopy is presented. The research focuses on the development of spectroscopic techniques for measuring high resolution spectral lineshape functions from the exciton phosphorescence in H/sub 2/-1,2,4,5-tetrachlorobenzene. It is found that the temperature dependent frequency shifts and widths confirm a theoretical model based on an exchange theory. The exchange of low energy phonon modes which couple with excited state exciton transitions is shown to display the proper temperature dependent behavior. In addition to the techniques for using the optical multichannel analyzer (OMA) to perform low light level target integration, the use of the OMA for capturing spectral information in transient pulsed laser applications is discussed. An OMP data acquisition system developed for real-time signal processng is described. Both hardware and software interfacing considerations for control and data acquisition by a microcomputer are described. The OMA detector is described in terms of the principles behind its photoelectron detection capabilities and its design is compared with other optoelectronic devices.

  6. Spectroelectrochemistry: The Combination of Optical and Electrochemical Techniques.

    Science.gov (United States)

    Heineman, William R.

    1983-01-01

    Two different techniques, electrochemistry and spectroscopy, can be combined for studying the redox chemistry of inorganic, organic, and biological molecules. Several commonly used spectroelectrochemical methods and their applications are described. Includes discussions of optically transparent electrodes, optical absorption/fluorescence…

  7. Surface diffusion studies by optical diffraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, X.D.

    1992-11-01

    The newly developed optical techniques have been combined with either second harmonic (SH) diffraction or linear diffraction off a monolayer adsorbate grating for surface diffusion measurement. Anisotropy of surface diffusion of CO on Ni(l10) was used as a demonstration for the second harmonic dim reaction method. The linear diffraction method, which possesses a much higher sensitivity than the SH diffraction method, was employed to study the effect of adsorbate-adsorbate interaction on CO diffusion on Ni(l10) surface. Results showed that only the short range direct CO-CO orbital overlapping interaction influences CO diffusion but not the long range dipole-dipole and CO-NI-CO interactions. Effects of impurities and defects on surface diffusion were further explored by using linear diffraction method on CO/Ni(110) system. It was found that a few percent S impurity can alter the CO diffusion barrier height to a much higher value through changing the Ni(110) surface. The point defects of Ni(l10) surface seem to speed up CO diffusion significantly. A mechanism with long jumps over multiple lattice distance initiated by CO filled vacancy is proposed to explain the observed defect effect.

  8. Cognitive Heterogeneous Reconfigurable Optical Networks (CHRON): Enabling Technologies and Techniques

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso; Zibar, Darko; Guerrero Gonzalez, Neil;

    2011-01-01

    We present the approach of cognition applied to heterogeneous optical networks developed in the framework of the EU project CHRON: Cognitive Heterogeneous Reconfigurable Optical Network. We introduce and discuss in particular the technologies and techniques that will enable a cognitive optical ne...

  9. Optical Measurement Techniques for Optical Fiber and Waveguide Devices

    Institute of Scientific and Technical Information of China (English)

    D.Y.; Kim; Y.; Park; N.H.; Seong; Y.C.Youk; J.Y.; Lee; S.; Moon; I.H.; Shin; H.S.; Ryu

    2003-01-01

    We describe three major optical characterization methods for fiber and fiber devices. A simple servo controlled scanning fiber-optic confocal microscope is proposed for determining the refractive index profile of an optical fiber. To measure the chromatic dispersion of a short length fiber a Mach-Zehnder fiber interferometer with a novel interferometric distance meter is introduced. At the end, a tomographic method is demonstrated for determining the 2-D stress profile of a fiber.

  10. Digital processing optical transmission and coherent receiving techniques

    CERN Document Server

    Binh, Le Nguyen

    2013-01-01

    With coherent mixing in the optical domain and processing in the digital domain, advanced receiving techniques employing ultra-high speed sampling rates have progressed tremendously over the last few years. These advances have brought coherent reception systems for lightwave-carried information to the next stage, resulting in ultra-high capacity global internetworking. Digital Processing: Optical Transmission and Coherent Receiving Techniques describes modern coherent receiving techniques for optical transmission and aspects of modern digital optical communications in the most basic lines. The

  11. Optical Imaging and Microscopy Techniques and Advanced Systems

    CERN Document Server

    Török, Peter

    2007-01-01

    This text on contemporary optical systems is intended for optical researchers and engineers, graduate students and optical microscopists in the biological and biomedical sciences. This second edition contains two completely new chapters. In addition most of the chapters from the first edition have been revised and updated. The book consists of three parts: The first discusses high-aperture optical systems, which form the backbone of optical microscopes. An example is a chapter new in the second edition on the emerging field of high numerical aperture diffractive lenses which seems to have particular promise in improving the correction of lenses. In this part particular attention is paid to optical data storage. The second part is on the use of non-linear optical techniques, including nonlinear optical excitation (total internal reflection fluorescence, second and third harmonic generation and two photon microscopy) and non-linear spectroscopy (CARS). The final part of the book presents miscellaneous technique...

  12. All Optical Signal-Processing Techniques Utilizing Four Wave Mixing

    Directory of Open Access Journals (Sweden)

    Refat Kibria

    2015-02-01

    Full Text Available Four Wave Mixing (FWM based optical signal-processing techniques are reviewed. The use of FWM in arithmetical operation like subtraction, wavelength conversion and pattern recognition are three key parts discussed in this paper after a brief introduction on FWM and its comparison with other nonlinear mixings. Two different approaches to achieve correlation are discussed, as well as a novel technique to realize all optical subtraction of two optical signals.

  13. Antifouling leaching technique for optical lenses

    Science.gov (United States)

    Strahle, William J.; Perez, C. L.; Martini, Marinna A.

    1994-01-01

    The effectiveness of optical lenses deployed in water less than 100 m deep is significantly reduced by biofouling caused by the settlement of macrofauna, such as barnacles, hydroids, and tunicates. However, machineable porous plastic rings can be used to dispense antifoulant into the water in front of the lens to retard macrofaunal growth without obstructing the light path. Unlike coatings which can degrade the optical performance, antifouling rings do not interfere with the instrument optics. The authors have designed plastic, reusable cup-like antifouling rings to slip over the optical lenses of a transmissometer. These rings have been used for several deployments on shallow moorings in Massachusetts Bay, MA and have increased the time before fouling degrades optical characteristics

  14. Optical coherence tomography: Technique and applications

    DEFF Research Database (Denmark)

    Thomsen, Jakob Borup; Sander, Birgit; Mogensen, Mette;

    2009-01-01

    Optical coherence tomography (OCT) is a noninvasive optical imaging modality providing real-time video rate images in two and three dimensions of biological tissues with micrometer resolution. OCT fills the gap between ultrasound and confocal microscopy, since it has a higher resolution than ultr...... of retinal diseases. The potential of OCT in many other applications is currently being explored, such as in developmental biology, skin cancer diagnostics, vulnerable plaque detection in cardiology, esophageal diagnostics and a number of other applications within oncology....

  15. A Study of Synchronization Techniques for Optical Communication Systems

    Science.gov (United States)

    Gagliardi, R. M.

    1975-01-01

    The study of synchronization techniques and related topics in the design of high data rate, deep space, optical communication systems was reported. Data cover: (1) effects of timing errors in narrow pulsed digital optical systems, (2) accuracy of microwave timing systems operating in low powered optical systems, (3) development of improved tracking systems for the optical channel and determination of their tracking performance, (4) development of usable photodetector mathematical models for application to analysis and performance design in communication receivers, and (5) study application of multi-level block encoding to optical transmission of digital data.

  16. Optically stimulated luminescence techniques in retrospective dosimetry

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Murray, A.S.

    2001-01-01

    Optically stimulated luminescence signals from natural quartz and feldspar are now used routinely in dating geological and archaeological materials. More recently they have also been employed in accident dosimetry, i.e. the retrospective assessment of doses received as a result of a nuclear...

  17. Machine learning techniques in optical communication

    DEFF Research Database (Denmark)

    Zibar, Darko; Piels, Molly; Jones, Rasmus Thomas

    2015-01-01

    Techniques from the machine learning community are reviewed and employed for laser characterization, signal detection in the presence of nonlinear phase noise, and nonlinearity mitigation. Bayesian filtering and expectation maximization are employed within nonlinear state-space framework...

  18. Machine learning techniques in optical communication

    DEFF Research Database (Denmark)

    Zibar, Darko; Piels, Molly; Jones, Rasmus Thomas

    2016-01-01

    Machine learning techniques relevant for nonlinearity mitigation, carrier recovery, and nanoscale device characterization are reviewed and employed. Markov Chain Monte Carlo in combination with Bayesian filtering is employed within the nonlinear state-space framework and demonstrated for parameter...

  19. Optical skin friction measurement technique in hypersonic wind tunnel

    Science.gov (United States)

    Chen, Xing; Yao, Dapeng; Wen, Shuai; Pan, Junjie

    2016-10-01

    Shear-sensitive liquid-crystal coatings (SSLCCs) have an optical characteristic that they are sensitive to the applied shear stress. Based on this, a novel technique is developed to measure the applied shear stress of the model surface regarding both its magnitude and direction in hypersonic flow. The system of optical skin friction measurement are built in China Academy of Aerospace Aerodynamics (CAAA). A series of experiments of hypersonic vehicle is performed in wind tunnel of CAAA. Global skin friction distribution of the model which shows complicated flow structures is discussed, and a brief mechanism analysis and an evaluation on optical measurement technique have been made.

  20. Optical Frequency Upconversion Technique for Transmission of Wireless MIMO-Type Signals over Optical Fiber

    OpenAIRE

    R. Q. Shaddad; Mohammad, A. B.; S. A. Al-Gailani; Al-Hetar, A. M.

    2014-01-01

    The optical fiber is well adapted to pass multiple wireless signals having different carrier frequencies by using radio-over-fiber (ROF) technique. However, multiple wireless signals which have the same carrier frequency cannot propagate over a single optical fiber, such as wireless multi-input multi-output (MIMO) signals feeding multiple antennas in the fiber wireless (FiWi) system. A novel optical frequency upconversion (OFU) technique is proposed to solve this problem. In this paper, the n...

  1. Optical correlator techniques applied to robotic vision

    Science.gov (United States)

    Hine, Butler P., III; Reid, Max B.; Downie, John D.

    1991-01-01

    Vision processing is one of the most computationally intensive tasks required of an autonomous robot. The data flow from a single typical imaging sensor is roughly 60 Mbits/sec, which can easily overload current on-board processors. Optical correlator-based processing can be used to perform many of the functions required of a general robotic vision system, such as object recognition, tracking, and orientation determination, and can perform these functions fast enough to keep pace with the incoming sensor data. We describe a hybrid digital electronic/analog optical robotic vision processing system developed at Ames Research Center to test concepts and algorithms for autonomous construction, inspection, and maintenance of space-based habitats. We discuss the system architecture design and implementation, its performance characteristics, and our future plans. In particular, we compare the performance of the system to a more conventional all digital electronic system developed concurrently. The hybrid system consistently outperforms the digital electronic one in both speed and robustness.

  2. Tear film measurement by optical reflectometry technique.

    Science.gov (United States)

    Lu, Hui; Wang, Michael R; Wang, Jianhua; Shen, Meixiao

    2014-02-01

    Evaluation of tear film is performed by an optical reflectometer system with alignment guided by a galvanometer scanner. The reflectometer system utilizes optical fibers to deliver illumination light to the tear film and collect the film reflectance as a function of wavelength. Film thickness is determined by best fitting the reflectance-wavelength curve. The spectral reflectance acquisition time is 15 ms, fast enough for detecting film thickness changes. Fast beam alignment of 1 s is achieved by the galvanometer scanner. The reflectometer was first used to evaluate artificial tear film on a model eye with and without a contact lens. The film thickness and thinning rate have been successfully quantified with the minimum measured thickness of about 0.3 μm. Tear films in human eyes, with and without a contact lens, have also been evaluated. A high-contrast spectral reflectance signal from the precontact lens tear film is clearly observed, and the thinning dynamics have been easily recorded from 3.69 to 1.31 μm with lipid layer thickness variation in the range of 41 to 67 nm. The accuracy of the measurement is better than ±0.58% of the film thickness at an estimated tear film refractive index error of ±0.001. The fiber-based reflectometer system is compact and easy to handle.

  3. Gabor-based fusion technique for Optical Coherence Microscopy.

    Science.gov (United States)

    Rolland, Jannick P; Meemon, Panomsak; Murali, Supraja; Thompson, Kevin P; Lee, Kye-sung

    2010-02-15

    We recently reported on an Optical Coherence Microscopy technique, whose innovation intrinsically builds on a recently reported - 2 microm invariant lateral resolution by design throughout a 2 mm cubic full-field of view - liquid-lens-based dynamic focusing optical probe [Murali et al., Optics Letters 34, 145-147, 2009]. We shall report in this paper on the image acquisition enabled by this optical probe when combined with an automatic data fusion method developed and described here to produce an in-focus high resolution image throughout the imaging depth of the sample. An African frog tadpole (Xenopus laevis) was imaged with the novel probe and the Gabor-based fusion technique, demonstrating subcellular resolution in a 0.5 mm (lateral) x 0.5 mm (axial) without the need, for the first time, for x-y translation stages, depth scanning, high-cost adaptive optics, or manual intervention. In vivo images of human skin are also presented.

  4. Phase retrieval techniques for adaptive optics

    Energy Technology Data Exchange (ETDEWEB)

    Carrano, C. J., LLNL

    1998-03-01

    We have developed and tested a method for minimizing static aberrations in adaptive optics systems. In order to correct the static phase aberrations, we need to measure the aberrations through the entire system. We have employed various phase retrieval algorithms to detect these aberrations. We have performed simulations of our experimental setup demonstrating that phase retrieval can improve the static aberrations to below the 20 nm rms level, with the limiting factor being local turbulence in the A0 system. Experimentally thus far, we have improved the static aberrations down to the 50 nm level, with the limiting factor being the ability to adjust the deformable mirror. This should be improved with better control algorithms now being implemented.

  5. Optical image segmentation using wavelet filtering techniques

    Science.gov (United States)

    Veronin, Christopher P.

    1990-12-01

    This research effort successfully implemented an automatic, optically based image segmentation scheme for locating potential targets in a cluttered FLIR image. Such a design is critical to achieve real-time segmentation and classification for machine vision applications. The segmentation scheme used in this research was based on texture discrimination and employs orientation specific, bandpass spatial filters as its main component. The orientation specific, bandpass spatial filters designed during this research include symmetrically located circular apertures implemented on heavy, black aluminum foil; cosine and sine Gabor filters implemented with detour-phase computer generated holography photoreduced onto glass slides; and symmetrically located circular apertures implemented on a liquid crystal television (LCTV) for real-time filter selection. The most successful design was the circular aperture pairs implemented on the aluminum foil. Segmentation was illustrated for simple and complex texture slides, glass template slides, and static and real-time FLIR imagery displayed on an LCTV.

  6. Field results of antifouling techniques for optical instruments

    Science.gov (United States)

    Strahle, W.J.; Hotchkiss, F.S.; Martini, M.A.

    1998-01-01

    An anti-fouling technique is developed for the protection of optical instruments from biofouling which leaches a bromide compound into a sample chamber and pumps new water into the chamber prior to measurement. The primary advantage of using bromide is that it is less toxic than the metal-based antifoulants. The drawback of the bromide technique is also discussed.

  7. Tumor margin detection using optical biopsy techniques

    Science.gov (United States)

    Zhou, Yan; Liu, Cheng-hui; Li, Jiyou; Li, Zhongwu; Zhou, Lixin; Chen, Ke; Pu, Yang; He, Yong; Zhu, Ke; Li, Qingbo; Alfano, Robert R.

    2014-03-01

    The aim of this study is to use the Resonance Raman (RR) and fluorescence spectroscopic technique for tumor margin detection with high accuracy based on native molecular fingerprints of breast and gastrointestinal (GI) tissues. This tumor margins detection method utilizes advantages of RR spectroscopic technique in situ and in real-time to diagnose tumor changes providing powerful tools for clinical guiding intraoperative margin assessments and postoperative treatments. The tumor margin detection procedures by RR spectroscopy were taken by scanning lesion from center or around tumor region in ex-vivo to find the changes in cancerous tissues with the rim of normal tissues using the native molecular fingerprints. The specimens used to analyze tumor margins include breast and GI carcinoma and normal tissues. The sharp margin of the tumor was found by the changes of RR spectral peaks within 2 mm distance. The result was verified using fluorescence spectra with 300 nm, 320 nm and 340 nm excitation, in a typical specimen of gastric cancerous tissue within a positive margin in comparison with normal gastric tissues. This study demonstrates the potential of RR and fluorescence spectroscopy as new approaches with labeling free to determine the intraoperative margin assessment.

  8. Study on application of optical clearing technique in skin diseases

    Science.gov (United States)

    Shan, Hao; Liang, Yanmei; Wang, Jingyi; Li, Yan

    2012-11-01

    So far, the study of the optical clearing is almost always about healthy tissue. However, the ultimate goal is to detect diseases for clinical application. Optical clearing on diseased skins is explored. The effect is evaluated by applying a combined liquid paraffin and glycerol mixed solution on several kinds of diseased skins in vitro. Scanning experiments from optical coherence tomography show that it has different effects among fibroma, pigmented nevus, and seborrheic keratosis. Based on the results, we conclude that different skin diseases have different compositions and structures, and their optical parameters and biological characteristics should be different, which implies that the optical clearing technique may have selectivity and may not be suitable for all kinds of skin diseases.

  9. Advanced Equalization Techniques for Digital Coherent Optical Receivers

    DEFF Research Database (Denmark)

    Arlunno, Valeria

    This PhD thesis addresses the design and performance evaluation of advanced Digital Signal Processing (DSP) algorithms for coherent optical fiber transmission systems. The research results presented in this thesis report on transmission of highly spectrally efficient optical communication systems...... employing multiplexing techniques with polarization multiplexing and multi-level modulations format. Advanced digital signal processing techniques offer robustness and flexibility for next generation high capacity optical fibre networks and are therefore considered as key building blocks in next generation...... format detection. Feedback equalization structure have been investigated in high order modulation formats transmission, when combined with coding techniques, and for closed spaced multiplexing scenario. Highlight results presented in this PhD thesis include evaluation and implementation of a novel...

  10. Congestion estimation technique in the optical network unit registration process.

    Science.gov (United States)

    Kim, Geunyong; Yoo, Hark; Lee, Dongsoo; Kim, Youngsun; Lim, Hyuk

    2016-07-01

    We present a congestion estimation technique (CET) to estimate the optical network unit (ONU) registration success ratio for the ONU registration process in passive optical networks. An optical line terminal (OLT) estimates the number of collided ONUs via the proposed scheme during the serial number state. The OLT can obtain congestion level among ONUs to be registered such that this information may be exploited to change the size of a quiet window to decrease the collision probability. We verified the efficiency of the proposed method through simulation and experimental results.

  11. Techniques for labeling of optical signals in bust switched networks

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso; Koonen, A. M. J.; Zhang, Jianfeng

    2003-01-01

    multiplexed (WDM) networks due to its single forwarding algorithm, thus yielding low latency, and it enables scaling to terabit rates. Moreover, LOBS is compatible with the general multiprotocol label switching (GMPLS) framework for a unified control plane. We present a review on techniques for labeling......We present a review of significant issues related to labeled optical burst switched (LOBS) networks and technologies enabling future optical internet networks. Labeled optical burst switching provides a quick and efficient forwarding mechanism of IP packets/bursts over wavelength division...

  12. Optical Frequency Upconversion Technique for Transmission of Wireless MIMO-Type Signals over Optical Fiber

    Directory of Open Access Journals (Sweden)

    R. Q. Shaddad

    2014-01-01

    Full Text Available The optical fiber is well adapted to pass multiple wireless signals having different carrier frequencies by using radio-over-fiber (ROF technique. However, multiple wireless signals which have the same carrier frequency cannot propagate over a single optical fiber, such as wireless multi-input multi-output (MIMO signals feeding multiple antennas in the fiber wireless (FiWi system. A novel optical frequency upconversion (OFU technique is proposed to solve this problem. In this paper, the novel OFU approach is used to transmit three wireless MIMO signals over a 20 km standard single mode fiber (SMF. The OFU technique exploits one optical source to produce multiple wavelengths by delivering it to a LiNbO3 external optical modulator. The wireless MIMO signals are then modulated by LiNbO3 optical intensity modulators separately using the generated optical carriers from the OFU process. These modulators use the optical single-sideband with carrier (OSSB+C modulation scheme to optimize the system performance against the fiber dispersion effect. Each wireless MIMO signal is with a 2.4 GHz or 5 GHz carrier frequency, 1 Gb/s data rate, and 16-quadrature amplitude modulation (QAM. The crosstalk between the wireless MIMO signals is highly suppressed, since each wireless MIMO signal is carried on a specific optical wavelength.

  13. Optical frequency upconversion technique for transmission of wireless MIMO-type signals over optical fiber.

    Science.gov (United States)

    Shaddad, R Q; Mohammad, A B; Al-Gailani, S A; Al-Hetar, A M

    2014-01-01

    The optical fiber is well adapted to pass multiple wireless signals having different carrier frequencies by using radio-over-fiber (ROF) technique. However, multiple wireless signals which have the same carrier frequency cannot propagate over a single optical fiber, such as wireless multi-input multi-output (MIMO) signals feeding multiple antennas in the fiber wireless (FiWi) system. A novel optical frequency upconversion (OFU) technique is proposed to solve this problem. In this paper, the novel OFU approach is used to transmit three wireless MIMO signals over a 20 km standard single mode fiber (SMF). The OFU technique exploits one optical source to produce multiple wavelengths by delivering it to a LiNbO3 external optical modulator. The wireless MIMO signals are then modulated by LiNbO3 optical intensity modulators separately using the generated optical carriers from the OFU process. These modulators use the optical single-sideband with carrier (OSSB+C) modulation scheme to optimize the system performance against the fiber dispersion effect. Each wireless MIMO signal is with a 2.4 GHz or 5 GHz carrier frequency, 1 Gb/s data rate, and 16-quadrature amplitude modulation (QAM). The crosstalk between the wireless MIMO signals is highly suppressed, since each wireless MIMO signal is carried on a specific optical wavelength.

  14. An Optical Fiber Displacement Sensor Using RF Interrogation Technique.

    Science.gov (United States)

    Kim, Hyeon-Ho; Choi, Sang-Jin; Jeon, Keum Soo; Pan, Jae-Kyung

    2016-02-24

    We propose a novel non-contact optical fiber displacement sensor. It uses a radio frequency (RF) interrogation technique which is based on bidirectional modulation of a Mach-Zehnder electro-optical modulator (MZ-EOM). The displacement is measured from the free spectral range (FSR) which is determined by the dip frequencies of the modulated MZ-EOM transfer function. In experiments, the proposed sensor showed a sensitivity of 456 kHz/mm or 1.043 kHz/V in a measurement range of 7 mm. The displacement resolution of the proposed sensor depends on the linewidth and the power of the optical source. Resolution better than 0.05 μm would be achieved if an optical source which has a linewidth narrower than 1.5 nm and a received power larger than -36 dBm is used. Also, the multiplexing characteristic of the proposed sensor was experimentally validated.

  15. Transmission line resonance technique for eccentric core optical fibers

    Science.gov (United States)

    Georgantzos, E.; Boucouvalas, A. C.

    2016-12-01

    In several cases optical fibers in telecommunications have cores of non circular geometry. Fibre optic deformations appear in optical fibres for many reasons. Optical fibre core ellipticity for example where the fibre optic core is not perfectly circular due to fibre optic manufacturing tolerances, is measured and often is a problem. Optical fibre core eccentricity, where the fibre core is not on the axis of the fibre, but it is offset by a small length. This is another issue and very important for ensuring performance low loss splices and connector losses. Both of ellipticity and eccentricity are specified in accordance to international standards for fibre optic manufacturing telecommunications grade fibres. The present paper studies ellipticity and core eccentricity specifically and presents a new method for analysing their effect. We present an extension of the transmission line technique as a means of studying such fibers and deriving necessary parameters. Conformal mapping on the other hand is a simple mathematical tool by which we can generate sets of orthogonal two-dimensional coordinate systems. Shortly a conformal map of Cartesian two-dimensional space is defined by any analytical function W(z) where z, w, are: z = x + jy, W = θ + j φ The function deriving by the conformal mapping transformation h(θ ,φ )=| ∂w/∂z | = 1/|∂z/∂w|, can be used in order to define ∇A → and ∇×A → where A → is the magnetic or electric field in the derived orthogonal coordinate system. Useful conformal maps for fiber optics applications should have the property that the equation θ(x, y) = constant, is forming closed curves in a Cartesian two-dimensional space (x,y). If θ(x, y) = constant represents a set of co-eccentric circles, we obtain the normal case of conventional fibers with circular cores. If θ(x, y) = constant represents a set of eclipses, we are have the formation of elliptic core optical fibers. If θ(x, y) = constant represents a set of

  16. Electro-optic techniques in electron beam diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    van Tilborg, Jeroen; Toth, Csaba; Matlis, Nicholas; Plateau, Guillaume; Leemans, Wim

    2011-06-17

    Electron accelerators such as laser wakefield accelerators, linear accelerators driving free electron lasers, or femto-sliced synchrotrons, are capable of producing femtosecond-long electron bunches. Single-shot characterization of the temporal charge profile is crucial for operation, optimization, and application of such accelerators. A variety of electro-optic sampling (EOS) techniques exists for the temporal analysis. In EOS, the field profile from the electron bunch (or the field profile from its coherent radiation) will be transferred onto a laser pulse co-propagating through an electro-optic crystal. This paper will address the most common EOS schemes and will list their advantages and limitations. Strong points that all techniques share are the ultra-short time resolution (tens of femtoseconds) and the single-shot capabilities. Besides introducing the theory behind EOS, data from various research groups is presented for each technique.

  17. Innovative, Inexpensive Etching Technique Developed for Polymer Electro- Optical Structures

    Science.gov (United States)

    Nguyen, Hung D.

    1999-01-01

    Electro-optic, polymer-based integrated optic devices for high-speed communication and computing applications offer potentially significant advantages over conventional inorganic electro-optic crystals. One key area of integrated optical technology--primary processing and fabrication--may particularly benefit from the use of polymer materials. However, as efforts concentrate on the miniaturization of electro-integrated circuit pattern geometries, the ability to etch fine features and smoothly sloped sidewalls is essential to make polymers useful for electro-integrated circuit applications. There are many existing processes available to etch polymer materials, but they all yield nearly vertical sidewalls. Vertical sidewalls are too difficult to reliably cover with a metal layer, and incomplete metalization degrades microwave performance, particularly at high frequency. However, obtaining a very sloped sidewall greatly improves the deposition of metal on the sidewall, leading to low-loss characteristics, which are essential to integrating these devices in highspeed electro-optic modulators. The NASA Lewis Research Center has developed in-house an inexpensive etching technique that uses a photolithography method followed by a simple, wet chemical etching process to etch through polymer layers. In addition to being simpler and inexpensive, this process can be used to fabricate smoothly sloped sidewalls by using a commercial none rodible mask: Spin-On-Glass. A commercial transparent material, Spin-On-Glass, uses processes and equipment similar to that for photoresist techniques.

  18. Optical and digital microscopic imaging techniques and applications in pathology.

    Science.gov (United States)

    Chen, Xiaodong; Zheng, Bin; Liu, Hong

    2011-01-01

    The conventional optical microscope has been the primary tool in assisting pathological examinations. The modern digital pathology combines the power of microscopy, electronic detection, and computerized analysis. It enables cellular-, molecular-, and genetic-imaging at high efficiency and accuracy to facilitate clinical screening and diagnosis. This paper first reviews the fundamental concepts of microscopic imaging and introduces the technical features and associated clinical applications of optical microscopes, electron microscopes, scanning tunnel microscopes, and fluorescence microscopes. The interface of microscopy with digital image acquisition methods is discussed. The recent developments and future perspectives of contemporary microscopic imaging techniques such as three-dimensional and in vivo imaging are analyzed for their clinical potentials.

  19. Sachse optical urethrotomy, a modified technique: 6 years of experience.

    Science.gov (United States)

    Sandozi, S; Ghazali, S

    1988-11-01

    Urethrotomy with the Sachse optical urethrotome has radically modified our management of strictures of the male urethra. A total of 143 patients underwent 210 procedures during 6 years. The strictures resolved in 85 per cent of the patients and they required no further treatment, including 52 patients followed for more than 6 years. A modified surgical technique using a pediatric cystoscope is described to inspect, traverse and cannulate the urethral stricture before optical urethrotomy, thus, enabling successful management of even the most difficult strictures. Our results confirm that the best prospects of cure were short and single urethral strictures, and that optical urethrotomy is the treatment of choice for strictures of the male urethra.

  20. Optical resilient packet ring (O-RPR) based on all-optical buffering techniques

    Science.gov (United States)

    Wu, Chongqing; Sheng, Xingzhi; Fu, Songnian; Wei, Bin; Li, Yajie; Liu, Aiming

    2006-01-01

    This paper reports the progress of the 863 high-technology project of China "Optical Resilient Packet Ring (O-RPR) Based on All-optical Buffering Techniques". In this ring network, for the packet through an intermediate node the conversion of O/E/O is not needed in order to overcome the bottleneck of O/E/O. In all-optical node a Dual Loop Optical Buffer (DLOB) is used to revolve the collision between the packet, which pass through the node, and add packet from local user to ring. The principle of DLOB is introduced. The bit-rate of head of optical frame is lower than the bit-rate of payload in a packet, in order to increase the efficiency of transmission link. This paper will introduce the network topology, layers and the structure of optical node. It includes an optical splitter, optical delay line as input buffer, a SOA as optical switch, which switch the packet dropping down form the ring or pass through the node, a DLOB and an electric buffer. An ARM is used for regulation of different buffers. The experiment results of a demonstrate network including 3 nodes are given.

  1. Optical, infrared and radio astronomy from techniques to observation

    CERN Document Server

    Poggiani, Rosa

    2017-01-01

    This textbook presents the established sciences of optical, infrared, and radio astronomy as distinct research areas, focusing on the science targets and the constraints that they place on instrumentation in the different domains. It aims to bridge the gap between specialized books and practical texts, presenting the state of the art in different techniques. For each type of astronomy, the discussion proceeds from the orders of magnitude for observable quantities that drive the building of instrumentation and the development of advanced techniques. The specific telescopes and detectors are then presented, together with the techniques used to measure fluxes and spectra. Finally, the instruments and their limits are discussed to assist readers in choice of setup, planning and execution of observations, and data reduction. The volume also includes worked examples and problem sets to improve student understanding; tables and figures in chapters summarize the state of the art of instrumentation and techniques.

  2. Optical Microstructures Fabricated with Direct Laser Writing Technique

    Directory of Open Access Journals (Sweden)

    Kowalczyk M.

    2014-12-01

    Full Text Available Three-dimensional photolitography, also known as Direct Laser Writing (DLW, is a powerful technique for fabrication of photonic microstructures. In this paper we present the basics of the relevant technology and discuss some features of the fabrication process. We also describe the experimental setup designed for making colour filters based on diffraction gratings, fibre-tip-integrated lens and anti-reflective coating designed for telecom wavelength (1550 nm. The results obtained demonstrate the DLW technique to be a promising fast prototyping fabrication method that may allow manipulating the properties of optical materials.

  3. Optical fiber sensors fabricated by the focused ion beam technique

    DEFF Research Database (Denmark)

    Yuan, Scott Wu; Wang, Fei; Bang, Ole

    2012-01-01

    crystal fiber (PCF). Using this technique we fabricate a highly compact fiber-optic Fabry-Pérot (FP) refractive index sensor near the tip of fiber taper, and a highly sensitive in-line temperature sensor in PCF. We also demonstrate the potential of using FIB to selectively fill functional fluid......Focused ion beam (FIB) is a highly versatile technique which helps to enable next generation of lab-on-fiber sensor technologies. In this paper, we demonstrate the use application of FIB to precisely mill the fiber taper and end facet of both conventional single mode fiber (SMF) and photonic...

  4. Ultrabroadband Phased-Array Receivers Based on Optical Techniques

    Science.gov (United States)

    2016-02-26

    AFRL-AFOSR-VA-TR-2016-0121 Ultrabroadband Phased-array Receivers Based on Optical Techniques Christopher Schuetz UNIVERSITY OF DELAWARE Final Report...NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) University of Delaware 210 Hullihen Hall Newark, DE 19716 8. PERFORMING ORGANIZATION...Rev. 8/98) Prescribed by ANSI Std . Z39.18 Adobe Professional 7.0 Reset INSTRUCTIONS FOR COMPLETING SF 298 1. REPORT DATE. Full publication date

  5. All-optical delay technique for supporting multiple antennas in a hybrid optical - wireless transmission system

    DEFF Research Database (Denmark)

    Prince, Kamau; Chiuchiarelli, A; Presi, M

    2008-01-01

    We introduce a novel continuously-variable optical delay technique to support beam-forming wireless communications systems using antenna arrays. We demonstrate delay with 64-QAM modulated signals at a rate of 15 Msymbol/sec with 2.5 GHz carrier frequency.......We introduce a novel continuously-variable optical delay technique to support beam-forming wireless communications systems using antenna arrays. We demonstrate delay with 64-QAM modulated signals at a rate of 15 Msymbol/sec with 2.5 GHz carrier frequency....

  6. Path radiance technique for retrieving aerosol optical thickness over land

    Energy Technology Data Exchange (ETDEWEB)

    Wen, Guoyong [Joint Center for Earth Systems Technology, University of Maryland, Baltimore County, Catonsville (United States); Tsay, Si-Chee [NASA Goddard Space Flight Center, Greenbelt, Maryland (United States); Cahalan, Robert F. [Joint Center for Earth Systems Technology, University of Maryland, Baltimore County, Catonsville (United States); NASA Goddard Space Flight Center, Greenbelt, Maryland (United States); Oreopoulos, Lazaros [Joint Center for Earth Systems Technology, University of Maryland, Baltimore County, Catonsville (United States)

    1999-12-27

    The key issue in retrieving aerosol optical thickness over land from shortwave satellite radiances is to identify and separate the signal due to scattering by a largely transparent aerosol layer from the noise due to reflection by the background surface, where the signal is relatively uniform compared to the highly inhomogeneous surface contribution. Sensitivity studies in aerosol optical thickness retrievals reveal that the apparent reflectance at the top of the atmosphere is very susceptible to the surface reflectance, especially when aerosol optical thickness is small. Uncertainties associated with surface reflectance estimation can greatly amplify the error of the aerosol optical thickness retrieval. To reduce these uncertainties, we have developed a ''path radiance'' method to retrieve aerosol optical thickness over land by extending the traditional technique that uses the ''dark object'' approach to extract the aerosol signal. This method uses the signature of the correlation of visible and middle-IR reflectance at the surface and couples the correlation with the atmospheric effect. We have applied this method to a Landsat TM (Thematic Mapper) image acquired over the Oklahoma southern Great Plains site of the Department of Energy Atmospheric Radiation Measurement (ARM) program on September 27, 1997, a very clear day (aerosol optical thickness of 0.07 at 0.5 {mu}m) during the first Landsat Intensive Observation Period. The retrieved mean aerosol optical thickness for TM band 1 at 0.49 {mu}m and band 3 at 0.66 {mu}m agree very well with the ground-based Sun photometer measurements at the ARM site. The ability to retrieve small aerosol optical thickness makes this path radiance technique promising. More importantly, the path radiance is relatively insensitive to surface inhomogeneity. The retrieved mean path radiances in reflectance units have very small standard deviations for both TM blue and red bands. This small

  7. New optical tomographic & topographic techniques for biomedical applications

    Science.gov (United States)

    Buytaert, Jan

    The mammalian middle ear contains the eardrum and the three auditory ossicles, and forms an impedance match between sound in air and pressure waves in the fluid of the inner ear. Without this intermediate system, with its unsurpassed efficiency and dynamic range, we would be practically deaf. Physics-based modeling of this extremely complex mechanical system is necessary to help our basic understanding of the functioning of hearing. Highly realistic models will make it possible to predict the outcome of surgical interventions and to optimize design of ossicle prostheses and active middle ear implants. To obtain such models and with realistic output, basic input data is still missing. In this dissertation I developed and used two new optical techniques to obtain two essential sets of data: accurate three-dimensional morphology of the middle ear structures, and elasticity parameters of the eardrum. The first technique is a new method for optical tomography of macroscopic biomedical objects, which makes it possible to measure the three-dimensional geometry of the middle ear ossicles and soft tissues which are connecting and suspending them. I made a new and high-resolution version of this orthogonal-plane fluorescence optical sectioning method, to obtain micrometer resolution in macroscopic specimens. The result is thus a complete 3-D model of the middle (and inner) ear of gerbil in unprecedented quality. On top of high-resolution morphological models of the middle ear structures, I applied the technique in other fields of research as well. The second device works according to a new optical profilometry technique which allows to measure shape and deformations of the eardrum and other membranes or objects. The approach is called projection moire profilometry, and creates moire interference fringes which contain the height information. I developed a setup which uses liquid crystal panels for grid projection and optical demodulation. Hence no moving parts are present and

  8. Metrology Optical Power Budgeting in SIM Using Statistical Analysis Techniques

    Science.gov (United States)

    Kuan, Gary M

    2008-01-01

    The Space Interferometry Mission (SIM) is a space-based stellar interferometry instrument, consisting of up to three interferometers, which will be capable of micro-arc second resolution. Alignment knowledge of the three interferometer baselines requires a three-dimensional, 14-leg truss with each leg being monitored by an external metrology gauge. In addition, each of the three interferometers requires an internal metrology gauge to monitor the optical path length differences between the two sides. Both external and internal metrology gauges are interferometry based, operating at a wavelength of 1319 nanometers. Each gauge has fiber inputs delivering measurement and local oscillator (LO) power, split into probe-LO and reference-LO beam pairs. These beams experience power loss due to a variety of mechanisms including, but not restricted to, design efficiency, material attenuation, element misalignment, diffraction, and coupling efficiency. Since the attenuation due to these sources may degrade over time, an accounting of the range of expected attenuation is needed so an optical power margin can be book kept. A method of statistical optical power analysis and budgeting, based on a technique developed for deep space RF telecommunications, is described in this paper and provides a numerical confidence level for having sufficient optical power relative to mission metrology performance requirements.

  9. Rapid cost-effective silicon carbide optical component manufacturing technique

    Science.gov (United States)

    Casstevens, John M.; Plummer, Ronald; Jarocki, Jim

    1999-10-01

    Silicon carbide may well be the best known material for the manufacture of high performance optical components. A combination of extremely high specific stiffness (r/E), high thermal conductivity and outstanding dimensional stability make silicon carbide superior overall to beryllium and low- expansion glass ceramics. A major impediment to wide use of silicon carbide in optical systems has been the costs of preliminary pressing, casting, shaping and final finishing of silicon carbide. Diamond grinding of silicon carbide is a slow and expensive process even on machines specially designed for the task. The process described here begins by machining the component from a special type of graphite. This graphite is easily machined with multi-axis CNC machine tools to any level of complexity and lightweighting required. The graphite is then converted completely to silicon carbide with very small and very predictable dimensional change. After conversion to silicon carbide the optical surface is coated with very fine grain silicon carbide which is easily polished to extreme smoothness using conventional optical polishing techniques. The fabrication process and a 6 inch diameter development mirror is described.

  10. Neurophotonics: non-invasive optical techniques for monitoring brain functions

    Science.gov (United States)

    Torricelli, Alessandro; Contini, Davide; Mora, Alberto Dalla; Pifferi, Antonio; Re, Rebecca; Zucchelli, Lucia; Caffini, Matteo; Farina, Andrea; Spinelli, Lorenzo

    2014-01-01

    Summary The aim of this review is to present the state of the art of neurophotonics, a recently founded discipline lying at the interface between optics and neuroscience. While neurophotonics also includes invasive techniques for animal studies, in this review we focus only on the non-invasive methods that use near infrared light to probe functional activity in the brain, namely the fast optical signal, diffuse correlation spectroscopy, and functional near infrared spectroscopy methods. We also present an overview of the physical principles of light propagation in biological tissues, and of the main physiological sources of signal. Finally, we discuss the open issues in models, instrumentation, data analysis and clinical approaches. PMID:25764252

  11. Optical and Digital Microscopic Imaging Techniques and Applications in Pathology

    Directory of Open Access Journals (Sweden)

    Xiaodong Chen

    2011-01-01

    Full Text Available The conventional optical microscope has been the primary tool in assisting pathological examinations. The modern digital pathology combines the power of microscopy, electronic detection, and computerized analysis. It enables cellular-, molecular-, and genetic-imaging at high efficiency and accuracy to facilitate clinical screening and diagnosis. This paper first reviews the fundamental concepts of microscopic imaging and introduces the technical features and associated clinical applications of optical microscopes, electron microscopes, scanning tunnel microscopes, and fluorescence microscopes. The interface of microscopy with digital image acquisition methods is discussed. The recent developments and future perspectives of contemporary microscopic imaging techniques such as three-dimensional and in vivo imaging are analyzed for their clinical potentials.

  12. Optical modulation techniques for analog signal processing and CMOS compatible electro-optic modulation

    Science.gov (United States)

    Gill, Douglas M.; Rasras, Mahmoud; Tu, Kun-Yii; Chen, Young-Kai; White, Alice E.; Patel, Sanjay S.; Carothers, Daniel; Pomerene, Andrew; Kamocsai, Robert; Beattie, James; Kopa, Anthony; Apsel, Alyssa; Beals, Mark; Mitchel, Jurgen; Liu, Jifeng; Kimerling, Lionel C.

    2008-02-01

    Integrating electronic and photonic functions onto a single silicon-based chip using techniques compatible with mass-production CMOS electronics will enable new design paradigms for existing system architectures and open new opportunities for electro-optic applications with the potential to dramatically change the management, cost, footprint, weight, and power consumption of today's communication systems. While broadband analog system applications represent a smaller volume market than that for digital data transmission, there are significant deployments of analog electro-optic systems for commercial and military applications. Broadband linear modulation is a critical building block in optical analog signal processing and also could have significant applications in digital communication systems. Recently, broadband electro-optic modulators on a silicon platform have been demonstrated based on the plasma dispersion effect. The use of the plasma dispersion effect within a CMOS compatible waveguide creates new challenges and opportunities for analog signal processing since the index and propagation loss change within the waveguide during modulation. We will review the current status of silicon-based electrooptic modulators and also linearization techniques for optical modulation.

  13. Differentiation of black gel inks using optical and chemical techniques.

    Science.gov (United States)

    Wilson, Jeffrey D; LaPorte, Gerald M; Cantu, Antonio A

    2004-03-01

    Gel ink pens have become a common writing instrument in the United States. Questioned document examiners often attempt to optically differentiate gel inks from each other and from other non-ballpoint ink writings (e.g., those from roller-ball pens). Since early formulations were primarily pigment-based, they do not elute when analyzed by thin-layer chromatography. However, recent gel ink formulations (i.e., within the past five years) include dye-based inks that can be easily separated. This study differentiates black gel inks using optical and chemical techniques. The techniques include: microscopy, visible and near infrared reflectance, near infrared luminescence, thin-layer chromatography (TLC), spot tests, and gas chromatography/mass spectrometry (GC/MS). As a result of this study a flow chart has been developed allowing for a systematic determination of a questioned ink. In addition, an analysis of volatile compounds found in gel inks revealed that there are some unique ingredients that may be found in gel inks that are not typically found in other non-ballpoint inks.

  14. Application of optical spectroscopic techniques for disease diagnosis

    Science.gov (United States)

    Saha, Anushree

    Optical spectroscopy, a truly non-invasive tool for remote diagnostics, is capable of providing valuable information on the structure and function of molecules. However, most spectroscopic techniques suffer from drawbacks, which limit their application. As a part of my dissertation work, I have developed theoretical and experimental methods to address the above mentioned issues. I have successfully applied these methods for monitoring the physical, chemical and biochemical parameters of biomolecules involved in some specific life threatening diseases like lead poisoning and age-related macular degeneration (AMD). I presented optical studies of melanosomes, which are one of the vital organelles in the human eye, also known to be responsible for a disease called age-related macular degeneration (AMD), a condition of advanced degeneration which causes progressive blindness. I used Raman spectroscopy, to first chemically identify the composition of melanosome, and then monitor the changes in its functional and chemical behavior due to long term exposure to visible light. The above study, apart from explaining the role of melanosomes in AMD, also sets the threshold power for lasers used in surgeries and other clinical applications. In the second part of my dissertation, a battery of spectroscopic techniques was successfully applied to explore the different binding sites of lead ions with the most abundant carrier protein molecule in our circulatory system, human serum albumin. I applied optical spectroscopic tools for ultrasensitive detection of heavy metal ions in solution which can also be used for lead detection at a very early stage of lead poisoning. Apart from this, I used Raman microspectroscopy to study the chemical alteration occurring inside a prostate cancer cell as a result of a treatment with a low concentrated aqueous extract of a prospective drug, Nerium Oleander. The experimental methods used in this study has tremendous potential for clinical

  15. A real-time technique for optical alignment of telescopes with segmented optics

    Science.gov (United States)

    DiVittorio, Michael; Gathright, John

    2003-02-01

    While telescopes with segmented optics (currently Keck and HET and in the future GTC, CELT, GSMT, NGST, etc) present extra challenges in terms of optical alignment, they also present the opportunity for using an alignment technique not available to telescopes with monolithic optics. We present a technique for aligning telescope secondary mirrors utilizing the segmented nature of the primary. The data required is gathered in direct image mode and can be collected from science instrument detectors (as compared to a wavefront sensor). From this data aberrations (focus and coma) are calculated from which secondary piston and tip/tilt (or decenter) corrections are determined. In addition, tip/tilt corrections for each of the primary mirror segments can also be calculated. Furthermore, other aberrations are available to determine other alignment or support issues including differentiating secondary tip/tilt from decenter, focal surface tilt, and instrument aberrations. This technique has been used nightly on the Keck I and II telescopes over the last 8 years and has made a significant improvement in image quality.

  16. New metrology techniques improve the production of silicon diffractive optics

    Science.gov (United States)

    Brooks, Cynthia B.; Gully-Santiago, Michael; Grigas, Michelle; Jaffe, Daniel T.

    2014-07-01

    Silicon immersion gratings and grisms offer significant advantages in compactness and performance over frontsurface gratings and over grisms made from lower-index materials. At the same time, the high refractive index of Si (3.4) leads to very stringent constraints on the allowable groove position errors, typically rms error of errors and their origins, we could then implement process controls for each step. The plasma uniformity was improved for the silicon nitride mask etch process and the phase contribution of the plasma etch step was measured. We then used grayscale lithography, a technique in which the photoresist is deliberately underexposed, to measure large-scale nonuniformities in the UV exposure system to an accuracy of 3-5%, allowing us to make corrections to the optical alignment. Additionally, we used a new multiple-exposure technique combined with laser interferometry to measure the relationship between UV exposure dose and line edge shift. From these data we predict the contribution of the etching and photolithographic steps to phase error of the grating surface. These measurements indicate that the errors introduced during the exposure step dominate the contributions of all the other processing steps. This paper presents the techniques used to quantify individual process contributions to phase errors and steps that were taken to improve overall phase uniformity.

  17. Radio & Optical Interferometry: Basic Observing Techniques and Data Analysis

    CERN Document Server

    Monnier, John D

    2012-01-01

    Astronomers usually need the highest angular resolution possible, but the blurring effect of diffraction imposes a fundamental limit on the image quality from any single telescope. Interferometry allows light collected at widely-separated telescopes to be combined in order to synthesize an aperture much larger than an individual telescope thereby improving angular resolution by orders of magnitude. Radio and millimeter wave astronomers depend on interferometry to achieve image quality on par with conventional visible and infrared telescopes. Interferometers at visible and infrared wavelengths extend angular resolution below the milli-arcsecond level to open up unique research areas in imaging stellar surfaces and circumstellar environments. In this chapter the basic principles of interferometry are reviewed with an emphasis on the common features for radio and optical observing. While many techniques are common to interferometers of all wavelengths, crucial differences are identified that will help new practi...

  18. Cloud cover estimation optical package: New facility, algorithms and techniques

    Science.gov (United States)

    Krinitskiy, Mikhail

    2017-02-01

    Short- and long-wave radiation is an important component of surface heat budget over sea and land. For estimating them accurate observations of the cloud cover are needed. While massively observed visually, for building accurate parameterizations cloud cover needs also to be quantified using precise instrumental measurements. Major disadvantages of the most of existing cloud-cameras are associated with their complicated design and inaccuracy of post-processing algorithms which typically result in the uncertainties of 20% to 30% in the camera-based estimates of cloud cover. The accuracy of these types of algorithm in terms of true scoring compared to human-observed values is typically less than 10%. We developed new generation package for cloud cover estimating, which provides much more accurate results and also allows for measuring additional characteristics. New algorithm, namely SAIL GrIx, based on routine approach, also developed for this package. It uses the synthetic controlling index ("grayness rate index") which allows to suppress the background sunburn effect. This makes it possible to increase the reliability of the detection of the optically thin clouds. The accuracy of this algorithm in terms of true scoring became 30%. One more approach, namely SAIL GrIx ML, we have used to increase the cloud cover estimating accuracy is the algorithm that uses machine learning technique along with some other signal processing techniques. Sun disk condition appears to be a strong feature in this kind of models. Artificial Neural Networks type of model demonstrates the best quality. This model accuracy in terms of true scoring increases up to 95,5%. Application of a new algorithm lets us to modify the design of the optical sensing package and to avoid the use of the solar trackers. This made the design of the cloud camera much more compact. New cloud-camera has already been tested in several missions across Atlantic and Indian oceans on board of IORAS research vessels.

  19. Design of Optical Systems with Extended Depth of Field: An Educational Approach to Wavefront Coding Techniques

    Science.gov (United States)

    Ferran, C.; Bosch, S.; Carnicer, A.

    2012-01-01

    A practical activity designed to introduce wavefront coding techniques as a method to extend the depth of field in optical systems is presented. The activity is suitable for advanced undergraduate students since it combines different topics in optical engineering such as optical system design, aberration theory, Fourier optics, and digital image…

  20. Optical techniques to understand biofunctional adaptation in human dentine

    Science.gov (United States)

    Kishen, Anil; Asundi, Anand K.

    2004-08-01

    Human tooth structure in the oral environment is subjected to mechanical forces and thermal fluctuations. Dentine, the major component of the tooth structure, is a bio-composite, mainly composed of a highly mineralized phase and a collagenous phase. When subjected to changes in load and/or temperature, dentine will experience stresses and strains distribution within their structure. Though such effects are found to cause deleterious effects on artificial dental restorations, biological structures such as dentine seem to posses an inherent ability to adapt to functional thermo-mechanical loads. Optical techniques enable visualization and quantification of deformation, strain and stress on dental structures and provide a better understanding on their thermo-mechanical response. In this study 2-dimensional and 3-dimensional digital photoelasticity, digital moiré interferometry and Electronic Speckle Pattern Interferometry (ESPI) are all shown to be quite promising in this application. This paper will highlight these techniques and the corresponding applications. These experiments will aid in designing and development of better dental restorations and implants in clinical practice.

  1. Turbo Equalization Techniques Toward Robust PDM 16-QAM Optical Fiber Transmission

    DEFF Research Database (Denmark)

    Arlunno, Valeria; Caballero Jambrina, Antonio; Borkowski, Robert

    2014-01-01

    In this paper, we show numerically and experimentally that turbo equalization (TE) is an efficient technique to mitigate performance degradations stemming from optical fiber propagation effects in both optical fiber dispersion managed and unmanaged coherent detection links. The effectiveness...

  2. Investigation of HIV-1 infected and uninfected cells using the optical trapping technique

    CSIR Research Space (South Africa)

    Ombinda-Lemboumba, Saturnin

    2017-02-01

    Full Text Available Optical trapping has emerged as an essential tool for manipulating single biological material and performing sophisticated spectroscopy analysis on individual cell. The optical trapping technique has been used to grab and immobilize cells from a...

  3. Optical nonlinearity of Rydberg electromagnetically induced transparency in thermal vapor using the optical-heterodyne-detection technique

    Science.gov (United States)

    Bhowmick, Arup; Sahoo, Sushree S.; Mohapatra, Ashok K.

    2016-08-01

    We discuss the optical-heterodyne-detection technique to study the absorption and dispersion of a probe beam propagating through a medium with a narrow resonance. The technique has been demonstrated for Rydberg electromagnetically induced transparency in rubidium thermal vapor and the optical nonlinearity of a probe beam with variable intensity has been studied. A quantitative comparison of the experimental result with a suitable theoretical model is presented. The limitations and the working regime of the technique are discussed.

  4. Suppression of phase-induced intensity noise in fibre optic delay line signal processors using an optical phase modulation technique.

    Science.gov (United States)

    Chan, Erwin H W

    2010-10-11

    A technique that can suppress the dominant phase-induced intensity noise in fibre optic delay line signal processors is presented. It is based on phase modulation of the optical carrier to distribute the phase noise at the information band into a high frequency band which can be filtered out. This technique is suitable for suppressing the phase noise in various delay line structures and for integrating in the conventional fibre optic links. It can also suppress the coherent interference effect at the same time. A model for predicting the amount of phase noise reduction in various delay line structures using the optical phase modulation technique is presented for the first time and is experimentally verified. Experimental results demonstrate the technique can achieve a large phase noise reduction in various fibre optic delay line signal processors.

  5. Online technique for detecting state of onboard fiber optic gyroscope.

    Science.gov (United States)

    Miao, Zhiyong; Xu, Dingjie; He, Kunpeng; Pang, Shuwan; Tian, Chunmiao

    2015-02-01

    Although angle random walk (ARW) of fiber optic gyroscope (FOG) has been well modeled and identified before being integrated into the high-accuracy attitude control system of satellite, aging and unexpected failures can affect the performance of FOG after launch, resulting in the variation of ARW coefficient. Therefore, the ARW coefficient can be regarded as an indicator of "state of health" for FOG diagnosis in some sense. The Allan variance method can be used to estimate ARW coefficient of FOG, however, it requires a large amount of data to be stored. Moreover, the procedure of drawing slope lines for estimation is painful. To overcome the barriers, a weighted state-space model that directly models the ARW to obtain a nonlinear state-space model was established for FOG. Then, a neural extended-Kalman filter algorithm was implemented to estimate and track the variation of ARW in real time. The results of experiment show that the proposed approach is valid to detect the state of FOG. Moreover, the proposed technique effectively avoids the storage of data.

  6. Online technique for detecting state of onboard fiber optic gyroscope

    Energy Technology Data Exchange (ETDEWEB)

    Miao, Zhiyong; He, Kunpeng, E-mail: pengkhe@126.com; Pang, Shuwan [Department of Automation, Harbin Engineering University, Harbin, Heilongjiang 150000 (China); Xu, Dingjie [School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, Heilongjiang 150000 (China); Tian, Chunmiao [Department of Information and Communication Engineering, Harbin Engineering University, Harbin, Heilongjiang 150000 (China)

    2015-02-15

    Although angle random walk (ARW) of fiber optic gyroscope (FOG) has been well modeled and identified before being integrated into the high-accuracy attitude control system of satellite, aging and unexpected failures can affect the performance of FOG after launch, resulting in the variation of ARW coefficient. Therefore, the ARW coefficient can be regarded as an indicator of “state of health” for FOG diagnosis in some sense. The Allan variance method can be used to estimate ARW coefficient of FOG, however, it requires a large amount of data to be stored. Moreover, the procedure of drawing slope lines for estimation is painful. To overcome the barriers, a weighted state-space model that directly models the ARW to obtain a nonlinear state-space model was established for FOG. Then, a neural extended-Kalman filter algorithm was implemented to estimate and track the variation of ARW in real time. The results of experiment show that the proposed approach is valid to detect the state of FOG. Moreover, the proposed technique effectively avoids the storage of data.

  7. Advanced Modulation Techniques for High-Performance Computing Optical Interconnects

    DEFF Research Database (Denmark)

    Karinou, Fotini; Borkowski, Robert; Zibar, Darko

    2013-01-01

    We experimentally assess the performance of a 64 × 64 optical switch fabric used for ns-speed optical cell switching in supercomputer optical interconnects. More specifically, we study four alternative modulation formats and detection schemes, namely, 10-Gb/s nonreturn-to-zero differential phase......-shift keying with balanced direct detection, 10-Gb/s polarization division multiplexed (PDM) quadrature phase-shift keying, 40-Gb/s single-polarization 16-ary quadrature amplitude modulation (16QAM), and 80-Gb/s PDM-16QAM, with coherent intradyne detection, in conjunction with an optimized version...... of the optical shared memory supercomputer interconnect system switch fabric. In particular, we investigate the resilience of the aforementioned advanced modulation formats to the nonlinearities of semiconductor optical amplifiers, used as ON/OFF gates in the supercomputer optical switch fabric under study...

  8. Study of optical techniques for the Ames unitary wind tunnel, part 7

    Science.gov (United States)

    Lee, George

    1993-01-01

    A summary of optical techniques for the Ames Unitary Plan wind tunnels are discussed. Six optical techniques were studied: Schlieren, light sheet and laser vapor screen, angle of attack, model deformation, infrared imagery, and digital image processing. The study includes surveys and reviews of wind tunnel optical techniques, some conceptual designs, and recommendations for use of optical methods in the Ames Unitary Plan wind tunnels. Particular emphasis was placed on searching for systems developed for wind tunnel use and on commercial systems which could be readily adapted for wind tunnels. This final report is to summarize the major results and recommendations.

  9. Differential Deposition Technique for Figure Corrections in Grazing Incidence X-ray Optics

    Science.gov (United States)

    Kilaru, Kiranmayee; Ramsey, Brian D.; Gubarev, Mikhail

    2009-01-01

    A differential deposition technique is being developed to correct the low- and mid-spatial-frequency deviations in the axial figure profile of Wolter type grazing incidence X-ray optics. These deviations arise due to various factors in the fabrication process and they degrade the performance of the optics by limiting the achievable angular resolution. In the differential deposition technique, material of varying thickness is selectively deposited along the length of the optic to minimize these deviations, thereby improving the overall figure. High resolution focusing optics being developed at MSFC for small animal radionuclide imaging are being coated to test the differential deposition technique. The required spatial resolution for these optics is 100 m. This base resolution is achievable with the regular electroform-nickel-replication fabrication technique used at MSFC. However, by improving the figure quality of the optics through differential deposition, we aim at significantly improving the resolution beyond this value.

  10. Novel applications of optical techniques to the study of buried semiconductor interfaces

    Science.gov (United States)

    Wilson, Barbara A.

    1989-01-01

    Detailed electronic and structural information about buried semiconductor interfaces obtained through application of optical techniques is discussed. The measurements described include the determination of band discontinuities, strain, and disorder associated with semiconductor heterointerfaces. The contactless and nondestructive nature of these optical techniques is particularly important for the study of heterointerfaces which are inherently inaccessible to direct electrical or physical contact.

  11. A novel technique for wireless optical communications with lenslet array processor

    Institute of Scientific and Technical Information of China (English)

    Weiqing Pan; Liren Liu; Hongzhan Liu; Shaogeng Deng

    2006-01-01

    @@ A novel communication technique is proposed, which utilizes a set ofmutually distinguishable optical pat terns instead of convergent facula to transmit information. Then the capacity is increased by exploiting the optical spatial bandwidth resources. At last, we experimentally demonstrate the proposed communication technique based on four 8 × 8 spatial pattern signals by using lenslet array processor.

  12. Simple optical decryption based on a modified joint transform correlator technique

    Institute of Scientific and Technical Information of China (English)

    WANG Huai-bin; WANG Tian-zuo; YUAN Xiao-cong

    2006-01-01

    A new encryption/decryption system for optical information security is proposed in this paper. We used an iterative Fourier transform algorithm to optimize the encrypted hologram as well as the decryption key as phase-only elements. The optical decryption was implemented by superimposing the encrypted hologram and the decryption key in a simple optical setup. Numerical simulation and optical experiment have confirmed the proposed technique as a simple and easy implementation for optical decryption, demonstrating potential applications in optical information security verification.

  13. Surface properties of hard protective coatings studied by optical techniques

    Science.gov (United States)

    Jaglarz, Janusz; Wolska, N.; Mitura, K.; Duraj, R.; Marszalek, K. W.; El Kouari, Y.

    2016-06-01

    The paper describes optical study of SiC, C and NiC layers deposited on Si substrates by double beam ion sputtering (DBIS) method. The following optical methods: ellipsometry, bidirectional reflection distribution function (BRDF) and total integrated scattering (TIS) studies have been applied. The obtained results allowed us to determine the refractive indices, extinction coefficients and the roughness parameters of DBIS films. Also surface profiles of optical constants determined from scanning ellipsometric measurements have been presented. The power spectral density functions (PSD) of surface roughness for studied samples have been determined. The influence of the deposition technology on film topography has been discussed.

  14. Myocardial Motion Estimation: An Evaluation of Optical Flow Computation Techniques on Echocardiographic Images

    Directory of Open Access Journals (Sweden)

    Slamet Riyadi

    2011-01-01

    Full Text Available The use of image processing technique for cardiac motion analysis has been an active research in the past decade. The estimation of myocardial motion eases the cardiologist in diagnosing cardiac abnormalities. In term of movement analysis, optical flow is the most popular technique that has been used by researchers. This paper describes the implementation and evaluation of three optical flow computation techniques to estimate the myocardial motion using echocardiographic images. The three techniquesare the global smoothness method (GSM, the local smoothness method (LSM and warping technique (WT. Optical flow field is computed based on healthy cardiac video on parasternal short axes view. These techniques look promising since the optical flow fields can be utilized to estimate the myocardial movement and comply with its true movement. The performances of each technique in terms of the direction, homogeneity and computing time, are also discussed.

  15. Evaluation of Mechanical Modal Characteristics Using Optical Techniques

    Science.gov (United States)

    Lekki, John; Adamovsky, Grigory; Flanagan, Patrick; Weiland, Ken

    2002-01-01

    In this paper the sensitivity of embedded fiber optic sensors to changes in modal characteristics of plates is discussed. In order to determine the feasibility of embedded fiber Bragg gratings for the detection of modal shapes and modal frequencies, a comparison of holographically imaged modes and the detected dynamic strain from embedded fiber optic Bragg gratings is made. Time averaged optical holography is used for the detection of mechanical defects, or damage, in various aerospace components. The damage is detected by measuring an alteration in structural dynamics, which is visually apparent when using time-averaged holography. These shifts in the mode shapes, both in frequency of the resonance and spatial location of vibration nodes, are caused by changes in parameters that affect the structure's mechanical impedance, such as stiffness, mass and damping, resulting from cracks or holes. It is anticipated that embedded fiber optic sensor arrays may also be able to detect component damage by sensing these changes in modal characteristics. This work is designed to give an initial indication to the feasibility of damage detection through the monitoring of modal frequencies and mode shapes with fiber optic sensors.

  16. Beaconless adaptive-optics technique for HEL beam control

    Science.gov (United States)

    Khizhnyak, Anatoliy; Markov, Vladimir

    2016-05-01

    Effective performance of forthcoming laser systems capable of power delivery on a distant target requires an adaptive optics system to correct atmospheric perturbations on the laser beam. The turbulence-induced effects are responsible for beam wobbling, wandering, and intensity scintillation, resulting in degradation of the beam quality and power density on the target. Adaptive optics methods are used to compensate for these negative effects. In its turn, operation of the AOS system requires a reference wave that can be generated by the beacon on the target. This report discusses a beaconless approach for wavefront correction with its performance based on the detection of the target-scattered light. Postprocessing of the beacon-generated light field enables retrieval and detailed characterization of the turbulence-perturbed wavefront -data that is essential to control the adaptive optics module of a high-power laser system.

  17. A Toolbox of Metrology-Based Techniques for Optical System Alignment

    Science.gov (United States)

    Coulter, Phillip; Ohl, Raymond G.; Blake, Peter N.; Bos, Brent J.; Eichhorn, William L.; Gum, Jeffrey S.; Hadjimichael, Theodore J.; Hagopian, John G.; Hayden, Joseph E.; Hetherington, Samuel E.; Kubalak, David A.; McLean, Kyle F.; McMann, Joseph; Redman, Kevin W.; Sampler, Henry P.; Wenzel, Greg W.; Young, Jerrod L.

    2016-01-01

    The NASA Goddard Space Flight Center (GSFC) and its partners have broad experience in the alignment of flight optical instruments and spacecraft structures. Over decades, GSFC developed alignment capabilities and techniques for a variety of optical and aerospace applications. In this paper, we provide an overview of a subset of the capabilities and techniques used on several recent projects in a "toolbox" format. We discuss a range of applications, from small-scale optical alignment of sensors to mirror and bench examples that make use of various large-volume metrology techniques. We also discuss instruments and analytical tools.

  18. A toolbox of metrology-based techniques for optical system alignment

    Science.gov (United States)

    Coulter, Phillip; Ohl, Raymond G.; Blake, Peter N.; Bos, Brent J.; Chambers, Victor J.; Eichhorn, William L.; Gum, Jeffrey S.; Hadjimichael, Theodore J.; Hagopian, John G.; Hayden, Joseph E.; Hetherington, Samuel E.; Kubalak, David A.; Mclean, Kyle F.; McMann, Joseph C.; Redman, Kevin W.; Sampler, Henry P.; Wenzel, Greg W.; Young, Jerrod L.

    2016-10-01

    The NASA Goddard Space Flight Center (GSFC) and its partners have broad experience in the alignment of flight optical instruments and spacecraft structures. Over decades, GSFC developed alignment capabilities and techniques for a variety of optical and aerospace applications. In this paper, we provide an overview of a subset of the capabilities and techniques used on several recent projects in a "toolbox" format. We discuss a range of applications, from small-scale optical alignment of sensors to mirror and bench examples that make use of various large-volume metrology techniques. We also discuss instruments and analytical tools.

  19. High-sensitive Optical Pulse-Shape Characterization using a Beating-Contrast-Measurement Technique

    CERN Document Server

    Roncin, Vincent; Millaud, Audrey; Cramer, Romain; Jaouën, Yves; Simon, Jean-Claude

    2014-01-01

    Ultrahigh-speed optical transmission technology, such as optical time domain multiplexing or optical signal processing is a key point for increasing the communication capacity. The system performances are strongly related to pulse properties. We present an original method dedicated to short pulse-shape characterization with high repetition rate using standard optical telecommunications equipments. Its principle is based on temporal measurement of the contrast produced by the beating of two delayed optical pulses in a high bandwidth photo detector. This technique returns firstly reliable information on the pulse-shape, such as pulse width, shape and pedestal. Simulation and experimental results evaluate the high-sensitivity and the high-resolution of the technique allowing the measurement of pulse extinction ratio up to 20 dB with typical timing resolution of about 100 fs. The compatibility of the technique with high repetition rate pulse measurement offers an efficient tool for short pulse analysis.

  20. The Development of a Differential Deposition Technique for Figure Correction in Grazing Incidence Optics Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the development of a physical-vapor-deposition coating technique to correct residual figure errors in grazing-incidence optics. The process involves...

  1. Fibre-optical techniques for measuring various properties of shock waves

    NARCIS (Netherlands)

    Prinse, W.C.; Esveld, R.J. van; Oostdam, R. van; Rooijen, M. van; Bouma, R.H.B.

    1999-01-01

    For the past years we have developed several optical techniques to measure properties of shock waves. The fibre optic probe (FOP) is developed to measure the shock-wave velocity and/or the detonation velocity inside an explosive. The space resolution can be as small as 0.5 mm. Single fibres are used

  2. Optical and digital microscopic imaging techniques and applications in pathology

    OpenAIRE

    Xiaodong Chen; Bin Zheng; Hong Liu

    2011-01-01

    The conventional optical microscope has been the primary tool in assisting pathological examinations. The modern digital pathology combines the power of microscopy, electronic detection, and computerized analysis. It enables cellular-, molecular-, and genetic-imaging at high efficiency and accuracy to facilitate clinical screening and diagnosis. This paper first reviews the fundamental concepts of microscopic imaging and introduces the technical features and associated clinical applications o...

  3. Exploring Techniques for Improving Retrievals of Bio-optical Properties of Coastal Waters

    Science.gov (United States)

    2013-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Exploring Techniques for Improving Retrievals of Bio ...Exploring Techniques for Improving Retrievals of Bio -optical Properties of Coastal Waters 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...retrieval of bio -optical properties, benefits from the leveraging of funding by NOAA CREST in which remote sensing of coastal waters is an important

  4. Improved optical performance monitoring technique based on nonlinear optics for high-speed WDM Nyquist systems

    Science.gov (United States)

    Guesmi, Latifa; Menif, Mourad

    2016-04-01

    The field of fiber optics nonlinearity is more discussed last years due to such remarkable enhancement in the nonlinear processes efficiency. In this paper, and for optical performance monitoring (OPM), a new achievement of nonlinear effects has been investigated. The use of cross-phase modulation (XPM) and four-wave mixing (FWM) effects between input optical signal and inserted continuous-wave probe has proposed for impairments monitoring. Indeed, transmitting a multi-channels phase modulated signal at high data rate (1 Tbps WDM Nyquist NRZ- DP-QPSK) improves the sensitivity and the dynamic range monitoring. It was observed by simulation results that various optical parameters including optical power, wavelength, chromatic dispersion (CD), polarization mode dispersion (PMD), optical signal-to-noise ratio (OSNR), Q-factor and so on, can be monitored. Also, the effect of increasing the channel spacing between WDM signals is studied and proved its use for FWM power monitoring.

  5. [The Autocad system for planimetric study of the optic disc in glaucoma: technique and reproducibility study].

    Science.gov (United States)

    Sánchez Pérez, A; Honrubia López, F M; Larrosa Poves, J M; Polo Llorens, V; Melcon Sánchez-Frieras, B

    2001-09-01

    To develop a lens planimetry technique for the optic disc using AutoCAD. To determine variability magnitude of the optic disc morphological measurements. We employed AutoCAD R.14.0 Autodesk: image acquisition, contour delimitation by multiple lines fitting or ellipse adjustment, image sectorialization and measurements quantification (optic disc and excavation, vertical diameters, optic disc area, excavation area, neuroretinal sector area and Beta atrophy area). Intraimage or operator and interimage o total reproducibility was studied by coefficient of variability (CV) (n=10) in normal and myopic optic discs. This technique allows to obtain optic disc measurement in 5 to 10 minutes time. Total or interimage variability of measurements introduced by one observer presents CV range from 1.18-4.42. Operator or intraimage measurement presents CV range from 0.30-4.21. Optic disc contour delimitation by ellipse adjustment achieved better reproducibility results than multiple lines adjustment in all measurements. Computer assisted AutoCAD planimetry is an interactive method to analyse the optic disc, feasible to incorporate to clinical practice. Reproducibility results are comparable to other analyzers in quantification optic disc morphology. Ellipse adjustment improves results in optic disc contours delimitation.

  6. Optical Trapping Techniques Applied to the Study of Cell Membranes

    Science.gov (United States)

    Morss, Andrew J.

    Optical tweezers allow for manipulating micron-sized objects using pN level optical forces. In this work, we use an optical trapping setup to aid in three separate experiments, all related to the physics of the cellular membrane. In the first experiment, in conjunction with Brian Henslee, we use optical tweezers to allow for precise positioning and control of cells in suspension to evaluate the cell size dependence of electroporation. Theory predicts that all cells porate at a transmembrane potential VTMof roughly 1 V. The Schwann equation predicts that the transmembrane potential depends linearly on the cell radius r, thus predicting that cells should porate at threshold electric fields that go as 1/r. The threshold field required to induce poration is determined by applying a low voltage pulse to the cell and then applying additional pulses of greater and greater magnitude, checking for poration at each step using propidium iodide dye. We find that, contrary to expectations, cells do not porate at a constant value of the transmembrane potential but at a constant value of the electric field which we find to be 692 V/cm for K562 cells. Delivering precise dosages of nanoparticles into cells is of importance for assessing toxicity of nanoparticles or for genetic research. In the second experiment, we conduct nano-electroporation—a novel method of applying precise doses of transfection agents to cells—by using optical tweezers in conjunction with a confocal microscope to manipulate cells into contact with 100 nm wide nanochannels. This work was done in collaboration with Pouyan Boukany of Dr. Lee's group. The small cross sectional area of these nano channels means that the electric field within them is extremely large, 60 MV/m, which allows them to electrophoretically drive transfection agents into the cell. We find that nano electroporation results in excellent dose control (to within 10% in our experiments) compared to bulk electroporation. We also find that

  7. Optical diffraction tomography techniques for the study of cell pathophysiology

    CERN Document Server

    Kim, Kyoohyun; Shin, Seungwoo; Lee, SangYun; Yang, Su-A; Park, YongKeun

    2016-01-01

    Three-dimensional imaging of biological cells is crucial for the investigation of cell biology, provide valuable information to reveal the mechanisms behind pathophysiology of cells and tissues. Recent advances in optical diffraction tomography (ODT) have demonstrated the potential for the study of various cells with its unique advantages of quantitative and label-free imaging capability. To provide insight on this rapidly growing field of research and to discuss its applications in biology and medicine, we present the summary of the ODT principle and highlight recent studies utilizing ODT with the emphasis on the applications to the pathophysiology of cells.

  8. Multiple Fan-Beam Optical Tomography: Modelling Techniques

    Directory of Open Access Journals (Sweden)

    Pang Jon Fea

    2009-10-01

    Full Text Available This paper explains in detail the solution to the forward and inverse problem faced in this research. In the forward problem section, the projection geometry and the sensor modelling are discussed. The dimensions, distributions and arrangements of the optical fibre sensors are determined based on the real hardware constructed and these are explained in the projection geometry section. The general idea in sensor modelling is to simulate an artificial environment, but with similar system properties, to predict the actual sensor values for various flow models in the hardware system. The sensitivity maps produced from the solution of the forward problems are important in reconstructing the tomographic image.

  9. Correction of Phase Distortion by Nonlinear Optical Techniques

    Science.gov (United States)

    1981-05-01

    ward wave oscillators and distributed feedback lasers, occur even in the presence of pump attenuation. It is obvious that pump depletion effects...a*. Efl v* Z* ^iCVb^^f-V VEfl> (4-3-2) Ik -VE +^ V,2 E - n— p p 2k T p 2nc W {M[(I +1 )En - (E -E*) t...offset techniques. (1) Since the pumps may be arranged to be non-counterpropagating with angle offset techniques, feedback of the pump into the

  10. Study on metal nanoparticles induced third-order optical nonlinearity in phenylhydrazone derivatives with DFWM technique

    Science.gov (United States)

    Sudheesh, P.; Rao, D. Mallikharjuna; Chandrasekharan, K.

    2014-01-01

    The third-order nonlinear optical properties of newly synthesized phenylhydrazone derivatives and the influence of noble metal nanoparticles (Ag & Au) on their nonlinear optical responses were investigated by employing Degenerate Four wave Mixing (DFWM) technique with a 7 nanosecond, 10Hz Nd: YAG laser pulses at 532nm. Metal nanoparticles were prepared by laser ablation and the particle formation was confirmed using UV-Visible spectroscopy, Transmission Electron Microscopy (TEM). The nonlinear optical susceptibility were measured and found to be of the order 10-13esu. The results are encouraging and conclude that the materials are promising candidate for future optical device applications.

  11. Frequency-Shifted Interferometry — A Versatile Fiber-Optic Sensing Technique

    Directory of Open Access Journals (Sweden)

    Fei Ye

    2014-06-01

    Full Text Available Fiber-optic sensing is a field that is developing at a fast pace. Novel fiber-optic sensor designs and sensing principles constantly open doors for new opportunities. In this paper, we review a fiber-optic sensing technique developed in our research group called frequency-shifted interferometry (FSI. This technique uses a continuous-wave light source, an optical frequency shifter, and a slow detector. We discuss the operation principles of several FSI implementations and show their applications in fiber length and dispersion measurement, locating weak reflections along a fiber link, fiber-optic sensor multiplexing, and high-sensitivity cavity ring-down measurement. Detailed analysis of FSI system parameters is also presented.

  12. Z-scan: A simple technique for determination of third-order optical nonlinearity

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Vijender, E-mail: chahal-gju@rediffmail.com [Department of Applied Science, N.C. College of Engineering, Israna, Panipat-132107, Haryana (India); Aghamkar, Praveen, E-mail: p-aghamkar@yahoo.co.in [Department of Physics, Chaudhary Devi Lal University, Sirsa-125055, Haryana (India)

    2015-08-28

    Z-scan is a simple experimental technique to measure intensity dependent nonlinear susceptibilities of third-order nonlinear optical materials. This technique is used to measure the sign and magnitude of both real and imaginary part of the third order nonlinear susceptibility (χ{sup (3)}) of nonlinear optical materials. In this paper, we investigate third-order nonlinear optical properties of Ag-polymer composite film by using single beam z-scan technique with Q-switched, frequency doubled Nd: YAG laser (λ=532 nm) at 5 ns pulse. The values of nonlinear absorption coefficient (β), nonlinear refractive index (n{sub 2}) and third-order nonlinear optical susceptibility (χ{sup (3)}) of permethylazine were found to be 9.64 × 10{sup −7} cm/W, 8.55 × 10{sup −12} cm{sup 2}/W and 5.48 × 10{sup −10} esu, respectively.

  13. Comparison of Modulation Techniques for Underwater Optical Wireless Communication Employing APD Receivers

    Directory of Open Access Journals (Sweden)

    Mazin Ali A. Ali

    2015-06-01

    Full Text Available In this study, we theoretically analyze the performance of an underwater optical wireless communications system using different modulation techniques and an avalanche photodiode APD receiver over underwater environment channels. Based on the LOS geometrical model and combined with signal to noise ratio model for Si and Ge APD and BER; then the impact of the distance of transmission and power of the transmitter and Jerlov water type are analyzed. The characteristics of bit error rate BER for different optical modulation techniques are studied. Simulation results indicate that the performance of H-QAM is more suited for an underwater optical wireless communication. On the other hand, the suitability of avalanche photodiodes under these modulation techniques is discussed, because the photodiode Si APD has more advantages compared with Ge APD when used in an underwater optical communication.

  14. Digital signal processing techniques for coherent optical communication

    Science.gov (United States)

    Goldfarb, Gilad

    Coherent detection with subsequent digital signal processing (DSP) is developed, analyzed theoretically and numerically and experimentally demonstrated in various fiber-optic transmission scenarios. The use of DSP in conjunction with coherent detection unleashes the benefits of coherent detection which rely on the preservaton of full information of the incoming field. These benefits include high receiver sensitivity, the ability to achieve high spectral-efficiency and the use of advanced modulation formats. With the immense advancements in DSP speeds, many of the problems hindering the use of coherent detection in optical transmission systems have been eliminated. Most notably, DSP alleviates the need for hardware phase-locking and polarization tracking, which can now be achieved in the digital domain. The complexity previously associated with coherent detection is hence significantly diminished and coherent detection is once gain considered a feasible detection alternative. In this thesis, several aspects of coherent detection (with or without subsequent DSP) are addressed. Coherent detection is presented as a means to extend the dispersion limit of a duobinary signal using an analog decision-directed phase-lock loop. Analytical bit-error ratio estimation for quadrature phase-shift keying signals is derived. To validate the promise for high spectral efficiency, the orthogonal-wavelength-division multiplexing scheme is suggested. In this scheme the WDM channels are spaced at the symbol rate, thus achieving the spectral efficiency limit. Theory, simulation and experimental results demonstrate the feasibility of this approach. Infinite impulse response filtering is shown to be an efficient alternative to finite impulse response filtering for chromatic dispersion compensation. Theory, design considerations, simulation and experimental results relating to this topic are presented. Interaction between fiber dispersion and nonlinearity remains the last major challenge

  15. Micro reflectance difference techniques: Optical probes for surface exploration

    Energy Technology Data Exchange (ETDEWEB)

    Lastras-Martinez, L.F.; Del Pozo-Zamudio, O.; Herrera-Jasso, R.; Ulloa-Castillo, N.A.; Balderas-Navarro, R.E.; Ortega-Gallegos, J.; Lastras-Martinez, A. [Instituto de Investigacion en Comunicacion Optica, Universidad Autonoma de San Luis Potosi, Alvaro Obregon 64, 78000 San Luis Potosi, S.L.P. (Mexico)

    2012-06-15

    Micro reflectance difference spectroscopy ({mu}-RDS) is a promising tool for the in-situ and ex-situ characterization of semiconductors surfaces and interfaces. We discuss and compare two different approaches used to measure {mu}-RD spectra. One is based on a charge-coupled device (CCD) camera, while the other uses a laser and a XY translation stage. To show the performance of these systems, we have measured surface optical anisotropies of GaSb(001) sample on which anisotropic strains have been generated by preferential mechanical polishing along [110] and [1 anti 10] directions. The spectrometers are complementary and the selection of one of them depends on the sample to be investigated and on experimental conditions. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Optical technique for measurement of random water wave surfaces

    Science.gov (United States)

    Sorrell, F. Y.; Withers, A. L.

    1976-01-01

    An optical system using the refraction of a vertical light ray has been developed for measuring the slope of random wind-generated water waves. The basic elements of the system are photovoltaic cells which are connected to individual amplifiers so that when the refracted light beam is incident on a cell, the output of the cell is amplified and then supplied as input to a comparator. The comparator then provides a specified voltage output, independent of the incident light intensity, as long as it is above a designated background value. The comparators are designed to give output voltages comparable with standard TTL. This arrangement provides a high signal from the cell when it experiences incident light, and a low signal when there is only background light, with the high and low signals at TTL voltage levels.

  17. Heterodyne technique for measuring the amplitude and phase transfer functions of an optical modulator

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2002-01-01

    In this letter, we propose a technique based on heterodyne detection for accurately and simultaneously measuring the amplitude and phase transfer functions of an optical modulator. The technique is used to characterize an InGaAsp multiple quantum-well electroabsorption modulator. From...

  18. Reticle defect sizing of optical proximity correction defects using SEM imaging and image analysis techniques

    Science.gov (United States)

    Zurbrick, Larry S.; Wang, Lantian; Konicek, Paul; Laird, Ellen R.

    2000-07-01

    Sizing of programmed defects on optical proximity correction (OPC) feature sis addressed using high resolution scanning electron microscope (SEM) images and image analysis techniques. A comparison and analysis of different sizing methods is made. This paper addresses the issues of OPC defect definition and discusses the experimental measurement results obtained by SEM in combination with image analysis techniques.

  19. Low voltage integrated optics electro-optical modulator applied to optical voltage transformer based on WLI technique

    Science.gov (United States)

    Santos, J. C.; Rubini, J.; Silva, L. P. C.; Caetano, R. E.

    2015-09-01

    The use of two electro-optical modulators linked in series, one for sensing and one for recovering signals, was formerly presented by some of the authors as a solution for interrogation of optical fiber sensor systems based on WLI method. A key feature required from such systems is that half-wave voltage (Vπ) of recovering modulator must be as small as possible. Aiming at meeting this requirement, in this paper it is presented the use of an unbalanced Michelson Interferometer implemented using an integrated optics component as recover interferometer in an optical voltage transformer intended for high voltage measurements.

  20. An Overview of Optical Character Recognition (OCR) Technology and Techniques.

    Science.gov (United States)

    1978-06-01

    using optico -electric filters. In practice, the choice of preprocessing techniques must necessarily be related to the recognition method. For example...inter- face), Recognition Unit and Operator Communication device. A brief description of each major system component including the Input Sensor follows...accomplish several types of mark- sensor recognition. Together, they are ’ capable of recognizing machine and handprinted data intermixed on the same line. .3

  1. Cleaning Verification Monitor Technique Based on Infrared Optical Methods

    Science.gov (United States)

    2004-10-01

    Cleaning Verification Techniques.” Real-time methods to provide both qualitative and quantitative assessments of surface cleanliness are needed for a...detection VCPI method offer a wide range of complementary capabilities in real-time surface cleanliness verification. Introduction Currently...also has great potential to reduce or eliminate premature failures of surface coatings caused by a lack of surface cleanliness . Additional

  2. Development of optical techniques for chemical engineering applications

    Energy Technology Data Exchange (ETDEWEB)

    Lamadie, F.; Charton, S.; Langlard, M. de; Ouattara, M.; Sentis, M. [CEA, Centre de Marcoule, DEN,DTEC,SGCS, F-30207 Marcoule (France)

    2016-07-01

    The design of separation processes for nuclear spend fuel treatment, dedicated to either research studies or industrial applications, is currently based on a phenomenological approach, relying on Computational Fluid Dynamics, and complemented by validation tests performed at small-scale. Indeed, most of the steps of the Purex process involve multiphasic flows (dissolution, leaching, liquid-liquid extraction, precipitation, filtration, etc.). Therefore an accurate knowledge of the dispersed phase properties is required in order to assess their coupling with the flow features, to predict the process performance and efficiency and to achieve size reduction or extrapolation. Hence, the measurements of particulate flows properties, and especially the particles (or drops or bubbles) size distribution, concentration (i.e. hold-up) and velocity has become a growing issue. Relevant techniques for measuring these flow properties are multiple, from the high-speed video acquisition coupled to image processing to the laser-induced fluorescence, including the particle imaging velocimetry or interferometric techniques (digital in-line holography, rainbow refractometry, etc.). In this communication, different techniques developed at CEA Marcoule for the characterization of multiphase flows, will be introduced. The strong interaction with computational fluid dynamics, in the scope of a multi-scale approach, will be discussed through typical results of gas-liquid, liquid-liquid and solid-liquid flows possibly encountered in nuclear fuel reprocessing process. (authors)

  3. Novel optical technique for 2D graphene reduction

    Science.gov (United States)

    Tharwat, Christen; Swillam, Mohamed A.; Badr, Y.; Ahmed, Samah M.; Bishay, I. K.; Sadallah, F. A.; Elsaid, Enayat A.

    2017-02-01

    Engineering a low-cost graphene- based opto-electronic device is a challenging task to accomplish via a single-step fabrication process. Recently scientists have started focusing on the development and use of a laser-based method for efficient reduction of graphene oxide (GO) films at low-temperature. Our proposed technique utilizes a laser beam for non thermal reduction of solution processed GO layers onto film substrates. Compared to other reduction techniques, it is a single-step, facile, time consuming, non-contact operation, environment-friendly, patternable, low cost, and can be performed at room temperature in ambient atmosphere without affecting the integrity of either the physical properties or the lattice of graphene. Laser scribed reduced graphene (LSRG) is shown to be successfully produced and selectively patterned from the direct laser irradiation of graphite oxide films under ambient conditions. In addition, by varying the laser's intensity, power, and irradiation treatments, the electrical properties of LSRG can be accurately attune over five orders of magnitude of conductivity. Feature has proven difficulty with other methods. This credible, scalable approach is mask-free, does not require certain expensive chemical reduction agents, and can be performed at ambient conditions starting from aqueous graphene oxide flakes. The non thermal nature of this method combined with its scalability and simplicity, makes it very attractive for the manufacturing of future generation large-volume graphene-based opto/electronics.

  4. Interferometric and nonlinear-optical spectral-imaging techniques for outer space and live cells

    Science.gov (United States)

    Itoh, Kazuyoshi

    2015-12-01

    Multidimensional signals such as the spectral images allow us to have deeper insights into the natures of objects. In this paper the spectral imaging techniques that are based on optical interferometry and nonlinear optics are presented. The interferometric imaging technique is based on the unified theory of Van Cittert-Zernike and Wiener-Khintchine theorems and allows us to retrieve a spectral image of an object in the far zone from the 3D spatial coherence function. The retrieval principle is explained using a very simple object. The promising applications to space interferometers for astronomy that are currently in progress will also be briefly touched on. An interesting extension of interferometric spectral imaging is a 3D and spectral imaging technique that records 4D information of objects where the 3D and spectral information is retrieved from the cross-spectral density function of optical field. The 3D imaging is realized via the numerical inverse propagation of the cross-spectral density. A few techniques suggested recently are introduced. The nonlinear optical technique that utilizes stimulated Raman scattering (SRS) for spectral imaging of biomedical targets is presented lastly. The strong signals of SRS permit us to get vibrational information of molecules in the live cell or tissue in real time. The vibrational information of unstained or unlabeled molecules is crucial especially for medical applications. The 3D information due to the optical nonlinearity is also the attractive feature of SRS spectral microscopy.

  5. Differential deposition technique for figure corrections in grazing-incidence x-ray optics

    Science.gov (United States)

    Kilaru, Kiranmayee; Ramsey, Brian D.; Gubarev, Mikhail V.; Gregory, Don A.

    2011-10-01

    A differential deposition technique was investigated as a way to minimize axial figure errors in full-shell, grazing-incidence, reflective x-ray optics. These types of optics use a combination of off-axis conic segments--hyperbolic, parabolic, and/or elliptical, to reflect and image x-rays. Several such mirrors or ``shells'' of decreasing diameter are typically concentrically nested to form a single focusing unit. Individual mirrors are currently produced at Marshall Space Flight Center using an electroforming technique, in which the shells are replicated off figured and superpolished mandrels. Several factors in this fabrication process lead to low- and mid-spatial frequency deviations in the surface profile of the shell that degrade the imaging quality of the optics. A differential deposition technique, discussed in this paper, seeks to improve the achievable resolution of the optics by correcting the surface profile deviations of the shells after fabrication. As a proof of concept, the technique was implemented on small-animal radionuclide-imaging x-ray optics being considered for medical applications. This paper discusses the deposition technique, its implementation, and the experimental results obtained to date.

  6. Cognition-Enabling Techniques in Heterogeneous and Flexgrid Optical Communication Networks

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso; Caballero Jambrina, Antonio; Saldaña Cercos, Silvia

    2012-01-01

    High degree of heterogeneity of future optical networks, such as services with different quality-of-transmission requirements, modulation formats and switching techniques, will pose a challenge for the control and optimization of different parameters. Incorporation of cognitive techniques can help...... to solve this issue by realizing a network that can observe, act, learn and optimize its performance, taking into account end-to-end goals. In this letter we present the approach of cognition applied to heterogeneous optical networks developed in the framework of the EU project CHRON: Cognitive...... Heterogeneous Reconfigurable Optical Network. We focus on the approaches developed in the project for optical performance monitoring and power consumption models to implement an energy efficient network....

  7. Signal Processing for Fibre-optic Distributed Sensing Techniques Employing Brillouin Scattering

    Institute of Scientific and Technical Information of China (English)

    XIAO Shang-hui; LI Li

    2009-01-01

    As fibre optic distributed scattering sensing systems are providing innovative solutions for the monitoring of large structures, Brillouin-based distributed scattering sensing techniques represent a new physical approach for structures health monitoring, which seems extremely promising and is receiving most attentions. This paper comprehensively presents some methods of signal interrogation for fibre optic Brillouin-based distributed scattering sensing technology, especially establishes an accurate Pseudo-Voigt model of Brillouin gain spectrum and gives some results on spectrum analysis and data processing.

  8. New optical gating technique for detection of electric field waveforms with subpicosecond resolution

    Science.gov (United States)

    Muraviev, Andrey; Gutin, Alexey; Rupper, Greg; Rudin, Sergey; Shen, Xiaohan; Yamaguchi, Masashi; Aizin, Gregory; Shur, Michael

    2016-06-01

    We report on the new optical gating technique used for the direct photoconductive detection of short pulses of terahertz radiation with the resolution up to 250 femtoseconds. The femtosecond optical laser pulse time delayed with respect to the THz pulse generated a large concentration of the electron hole pairs in the AlGaAs/InGaAs High Electron Mobility Transistor (HEMT) drastically increasing the conductivity on the femtosecond scale and effectively shorting the source and drain. This optical gating quenched the response of the plasma waves launched by the THz pulse and allowed us to reproduce the waveform of the THz pulse by varying the time delay between the THz and quenching optical pulses. The results are in excellent agreement with the electro-optic effect measurements and with our hydrodynamic model that predicts the ultra-fast transistor plasmonic response at the time scale much shorter than the electron transit time, in full agreement with the measured data.

  9. Evaluation of a fiber-optic technique for recording intramuscular pressure in the human leg.

    Science.gov (United States)

    Nilsson, Andreas; Zhang, Qiuxia; Styf, Jorma

    2016-10-01

    To evaluate a forward-sensing fiber-optic pressure technique for recording of intramuscular pressure (IMP) in the human leg and investigate factors that may influence IMP measurements used in diagnosing compartment syndromes. IMP in the tibialis anterior muscle was recorded simultaneously by a fiber-optic technique and needle-injection technique in 12 legs of 7 healthy subjects. Both measurement catheters were placed in parallel with the muscle fibers to the same depth, as verified by sonography. IMP recordings were performed at rest before, during and after applying a model of abnormally elevated IMP (simulated compartment syndrome). IMP was elevated by venous obstruction induced by a thigh tourniquet of a casted leg. IMP was also measured during injections of 0.1 ml of saline into the muscle through the catheters. IMP at baseline was 5.1 (SD = 2.6) mmHg measured with the fiber-optic technique and 7.1 (SD = 2.5) mmHg with the needle-injection technique (p syndrome. IMP increased significantly following injection of 0.1 ml of saline, measured by both techniques. It remained increased 1 min after injection. The fiber-optic technique was able to record pulse-synchronous IMP oscillations. The fiber-optic technique may be used for IMP measurements in a muscle with both normal and abnormally elevated IMP. It has good dynamic properties allowing for measurement of IMP oscillations. Saline injection used with needle-injection systems to ensure catheter patency compromises IMP readings at least one minute after injection.

  10. Picosecond optical nonlinearities in symmetrical and unsymmetrical phthalocyanines studied using the Z-scan technique

    Indian Academy of Sciences (India)

    S Venugopal Rao; P T Anusha; L Giribabu; Surya P Tewari

    2010-11-01

    We present our experimental results on the picosecond nonlinear optical (NLO) studies of symmetrical and unsymmetrical phthalocyanines, examined using the Z-scan technique. Both the open-aperture and closed-aperture Z-scan curves for three samples were recorded and the nonlinear coefficients were extracted from the theoretical fits. The nonlinear absorption/refraction contribution from the solvent was also identified. The observed open aperture behaviour for these molecules is understood in terms of the absorption coefficients of these molecules near 800 nm and the peak intensities used. It is established that these phthalocyanines exhibit large optical nonlinearities and, hence, are suitable for optical limiting applications.

  11. Large Volume, Optical and Opto-Mechanical Metrology Techniques for ISIM on JWST

    Science.gov (United States)

    Hadjimichael, Theo

    2015-01-01

    The final, flight build of the Integrated Science Instrument Module (ISIM) element of the James Webb Space Telescope is the culmination of years of work across many disciplines and partners. This paper covers the large volume, ambient, optical and opto-mechanical metrology techniques used to verify the mechanical integration of the flight instruments in ISIM, including optical pupil alignment. We present an overview of ISIM's integration and test program, which is in progress, with an emphasis on alignment and optical performance verification. This work is performed at NASA Goddard Space Flight Center, in close collaboration with the European Space Agency, the Canadian Space Agency, and the Mid-Infrared Instrument European Consortium.

  12. Magnetic Diagnostics of the Solar Corona: Synthesizing Optical and Radio Techniques

    Science.gov (United States)

    Casini, R.; White, S. M.; Judge, P. G.

    2017-09-01

    In this contribution we review the current state-of-the-art of coronal magnetometry, in both optical and radio domains. We address the achievable objectives and the challenges of present measurement techniques and interpretation tools. In particular, we focus on the role that these observations can play for constraining and validating numerical models of the global coronal magnetic field. With regard to optical techniques, we mainly focus on the use of M1 diagnostics, further developing the theory of the formation of their polarization signatures in the magnetized corona.

  13. Optical Fourier techniques for medical image processing and phase contrast imaging.

    Science.gov (United States)

    Yelleswarapu, Chandra S; Kothapalli, Sri-Rajasekhar; Rao, D V G L N

    2008-04-01

    This paper briefly reviews the basics of optical Fourier techniques (OFT) and applications for medical image processing as well as phase contrast imaging of live biological specimens. Enhancement of microcalcifications in a mammogram for early diagnosis of breast cancer is the main focus. Various spatial filtering techniques such as conventional 4f filtering using a spatial mask, photoinduced polarization rotation in photosensitive materials, Fourier holography, and nonlinear transmission characteristics of optical materials are discussed for processing mammograms. We also reviewed how the intensity dependent refractive index can be exploited as a phase filter for phase contrast imaging with a coherent source. This novel approach represents a significant advance in phase contrast microscopy.

  14. Implementation of pulse interval modulation based on dualmapping technique for optical wireless communications

    Institute of Scientific and Technical Information of China (English)

    ZHANG Tie-ying; WANG Hong-xing; HU Hao; CONG Pei-sheng

    2009-01-01

    Aiming at implementing the digital pulse interval modulation (DPIM) for optical wireless communications (OWC), a dual-mapping technique is presented. The scheme of DPIM train based upon the dual-mapping technique is given. Its slot error rate is derived for the avalanche photonic diode (APD) receiver model, and is compared with that of classical DPIM. Simulation results show that the dual-mapping DPIM (D-DPIM), which has a fixed slot length, only has marginally inferior error performance, but can solve waiting slots or buffer overflowing in comparison with DPIM. Hence, it is suitable for the optical wireless communication systems.

  15. Cerebral blood flow and autoregulation: current measurement techniques and prospects for noninvasive optical methods.

    Science.gov (United States)

    Fantini, Sergio; Sassaroli, Angelo; Tgavalekos, Kristen T; Kornbluth, Joshua

    2016-07-01

    Cerebral blood flow (CBF) and cerebral autoregulation (CA) are critically important to maintain proper brain perfusion and supply the brain with the necessary oxygen and energy substrates. Adequate brain perfusion is required to support normal brain function, to achieve successful aging, and to navigate acute and chronic medical conditions. We review the general principles of CBF measurements and the current techniques to measure CBF based on direct intravascular measurements, nuclear medicine, X-ray imaging, magnetic resonance imaging, ultrasound techniques, thermal diffusion, and optical methods. We also review techniques for arterial blood pressure measurements as well as theoretical and experimental methods for the assessment of CA, including recent approaches based on optical techniques. The assessment of cerebral perfusion in the clinical practice is also presented. The comprehensive description of principles, methods, and clinical requirements of CBF and CA measurements highlights the potentially important role that noninvasive optical methods can play in the assessment of neurovascular health. In fact, optical techniques have the ability to provide a noninvasive, quantitative, and continuous monitor of CBF and autoregulation.

  16. Photodynamic diagnosis and related optical techniques for the management of malignant glioma

    Science.gov (United States)

    Sroka, R.; Stepp, H.; Beyer, W.; Markwardt, N.; Rühm, A.

    2017-04-01

    Malignant gliomas are a devastating brain tumor disease with very poor prognosis. Stereotactic biopsy sampling is routinely used in larger neurosurgical centers to confirm the diagnosis of a suspected brain tumor. This procedure is associated with risk of blood vessel rupture as well as false-negative results. Recent investigations suggest a potential of light-based techniques to improve both therapy and diagnosis of GBM. Optical guidance can be utilized to improve the biopsy sampling procedure in terms of safety, reliability, and efficacy. Recording of optical signals (transmission, remission, fluorescence) can be potentially integrated into a biopsy needle for providing optical detection of tumor tissue and blood vessel recognition during the biopsy sampling. Optical signals can also be used for monitoring purposes during photodynamic therapy. Here, fluorescence signals recorded before the treatment indicate the presence and accumulation level of photosensitizer, while photobleaching of the photosensitizer fluorescence during the treatment can be used as a measure of the effectiveness of the therapy. Finally, transmitted light can reveal problematic tissue-optical conditions as well as changes of the optical properties of the treated tissue, which may be relevant with regard to treatment prognosis and strategy. Different optical concepts for interstitial PDT monitoring and optical tissue property assessment are presented.

  17. Simultaneous PIV and pulsed shadow technique in slug flow: a solution for optical problems

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, S. [Karman Institute for Fluid Dynamics, Chaussee de Waterloo 72, B-1640, Rhode Saint Genese (Belgium); Centro de Estudos de Fenomenos de Transporte, Departamento de Eng. Quimica, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465, Porto (Portugal); Sousa, R.G.; Pinto, A.M.F.R.; Campos, J.B.L.M. [Centro de Estudos de Fenomenos de Transporte, Departamento de Eng. Quimica, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465, Porto (Portugal); Riethmuller, M.L. [Karman Institute for Fluid Dynamics, Chaussee de Waterloo 72, B-1640, Rhode Saint Genese (Belgium)

    2003-12-01

    A recent technique of simultaneous particle image velocimetry (PIV) and pulsed shadow technique (PST) measurements, using only one black and white CCD camera, is successfully applied to the study of slug flow. The experimental facility and the operating principle are described. The technique is applied to study the liquid flow pattern around individual Taylor bubbles rising in an aqueous solution of glycerol with a dynamic viscosity of 113 x 10{sup -3} Pa s. With this technique the optical perturbations found in PIV measurements at the bubble interface are completely solved in the nose and in annular liquid film regions as well as in the rear of the bubble for cases in which the bottom is flat. However, for Taylor bubbles with concave oblate bottoms, some optical distortions appear and are discussed. The measurements achieved a spatial resolution of 0.0022 tube diameters. The results reported show high precision and are in agreement with theoretical and experimental published data. (orig.)

  18. Optical techniques for signal distribution and control in advanced radar and communication systems

    Science.gov (United States)

    Forrest, J. R.

    1985-03-01

    It is concluded that optical techniques offer some advantages for signal distribution and control in advanced radar and communication systems. They are clearly ideal for transporting microwave signals over considerable distances, as in remote positioning of radar receivers, provided high dynamic range is not required and an enclosed transmission path is essential. They are an elegant means of distributing low level r.f. or i.f. signals around an active phased array where these signals are of relatively constant amplitude (as in mixer local oscillator applications). However, there is currently a rather restrictive limit on the size of distribution network possible. Optical techniques are obviously suitable for distributing digital control signals to phased array modules and confer considerable immunity to interference. They are less suitable for high dynamic range signals, such as the received radar returns, either at r.f. or when downcovered to i.f. Future developments in coherent optics or in fast optical A/D technology could, however, influence this conclusion. Currently, the optimum applications for optical techniques appear to be i.f. beamformers for multibeam communication satellite systems and in calibration/monitoring systems for phased arrays.

  19. Ultrabroadband phased-array radio frequency (RF) receivers based on optical techniques

    Science.gov (United States)

    Overmiller, Brock M.; Schuetz, Christopher A.; Schneider, Garrett; Murakowski, Janusz; Prather, Dennis W.

    2014-03-01

    Military operations require the ability to locate and identify electronic emissions in the battlefield environment. However, recent developments in radio detection and ranging (RADAR) and communications technology are making it harder to effectively identify such emissions. Phased array systems aid in discriminating emitters in the scene by virtue of their relatively high-gain beam steering and nulling capabilities. For the purpose of locating emitters, we present an approach realize a broadband receiver based on optical processing techniques applied to the response of detectors in conformal antenna arrays. This approach utilizes photonic techniques that enable us to capture, route, and process the incoming signals. Optical modulators convert the incoming signals up to and exceeding 110 GHz with appreciable conversion efficiency and route these signals via fiber optics to a central processing location. This central processor consists of a closed loop phase control system which compensates for phase fluctuations induced on the fibers due to thermal or acoustic vibrations as well as an optical heterodyne approach for signal conversion down to baseband. Our optical heterodyne approach uses injection-locked paired optical sources to perform heterodyne downconversion/frequency identification of the detected emission. Preliminary geolocation and frequency identification testing of electronic emissions has been performed demonstrating the capabilities of our RF receiver.

  20. Reconstruction of elongated bubbles fusing the information from multiple optical probes through a Bayesian inference technique.

    Science.gov (United States)

    Chakraborty, Shubhankar; Roy Chaudhuri, Partha; Das, Prasanta Kr

    2016-07-01

    In this communication, a novel optical technique has been proposed for the reconstruction of the shape of a Taylor bubble using measurements from multiple arrays of optical sensors. The deviation of an optical beam passing through the bubble depends on the contour of bubble surface. A theoretical model of the deviation of a beam during the traverse of a Taylor bubble through it has been developed. Using this model and the time history of the deviation captured by the sensor array, the bubble shape has been reconstructed. The reconstruction has been performed using an inverse algorithm based on Bayesian inference technique and Markov chain Monte Carlo sampling algorithm. The reconstructed nose shape has been compared with the true shape, extracted through image processing of high speed images. Finally, an error analysis has been performed to pinpoint the sources of the errors.

  1. Survey of energy efficient tracking and localization techniques in buildings using optical and wireless communication media

    NARCIS (Netherlands)

    Bruintjes, Tom M.; Kokkeler, André B.J.; Karagiannis, Georgios; Smit, Gerard J.M.

    2012-01-01

    This paper presents a survey of beamforming, beamsteering and mobile tracking techniques. The survey was made in the context of the SOWICI project. The aim of this project is to reduce power consumption of data exchanging devices within houses. An optical fiber network is used for data transport to

  2. Observer-Based Control Techniques for the LBT Adaptive Optics under Telescope Vibrations

    NARCIS (Netherlands)

    Agapito, Guido; Quirós-Pacheco, Fernando; Tesi, Pietro; Riccardi, Armando; Esposito, Simone

    2011-01-01

    This paper addresses the application of observer-based control techniques for the adaptive optics system of the LBT telescope. In such a context, attention is focused on the use of Kalman and H∞ filters to estimate the temporal evolution of phase perturbations due to the atmospheric turbulence and

  3. Dispersion Monitoring techniques in High Bit-rate Optical Communication Systems

    Institute of Scientific and Technical Information of China (English)

    SANG Xin-zhu; YU Chong-xiu; ZHANG Qi; WANG Xu

    2004-01-01

    For the efficient dynamic dispersion compensation, it is essential to monitor the dispersion accurately. The existing main dispersion monitoring techniques in high bit- rate optical communication systems are presented as well as their operating principles and research progress. The advantages and disadvantages of these methods are analyzed and discussed.

  4. Monitoring programmed cell death of living plant tissues in microfluidics using electrochemical and optical techniques

    DEFF Research Database (Denmark)

    Mark, Christina; Zor, Kinga; Heiskanen, Arto

    This project focuses on developing and applying a tissue culture system with electrochemical and optical detection techniques for tissue culture of barley aleurone layer to increase understanding of the underlying mechanisms of programmed cell death (PCD) in plants. The major advantage of electro...

  5. Monitoring the stress build-up in dental cements: a novel optical characterization technique

    Science.gov (United States)

    Ottevaere, Heidi; Tabak, M.; Bartholomees, F.; de Wilde, Willy P.; Veretennicoff, Irina P.; Thienpont, Hugo

    2001-01-01

    It is well known that during the curing of dental cements, polymerization shrinkage induces unacceptable stresses, which can result into cracks and an over-sensitivity of the teeth. We demonstrate that polarimetric optical fiber sensors can be used to characterize this shrinkage quantitatively. To determine the time evolution and the amount of shrinkage we embed a highly birefringent optical fiber in the dental cement and analyze the change in optical polarization at its output. This change is a measure for the dynamic stress-build up. We also demonstrate the repeatability of our characterization method for these cements. Moreover we given indications that this technique allows for in- vivo monitoring of the stress build-up dynamics between dentine and porcelain facings. This may bring durable all-ceramic restorations closer to reality. In this paper we present the principle of this original optical fiber sensor, its practical implementation and the experimental results we obtained for this application.

  6. Frontiers of Optical Spectroscopy Investigating Extreme Physical Conditions with Advanced Optical Techniques

    CERN Document Server

    Bartolo, Baldassare

    2005-01-01

    Advanced spectroscopic techniques allow the probing of very small systems and very fast phenomena, conditions that can be considered "extreme" at the present status of our experimentation and knowledge. Quantum dots, nanocrystals and single molecules are examples of the former and events on the femtosecond scale examples of the latter. The purpose of this book is to examine the realm of phenomena of such extreme type and the techniques that permit their investigations. Each author has developed a coherent section of the program starting at a somewhat fundamental level and ultimately reaching the frontier of knowledge in the field in a systematic and didactic fashion. The formal lectures are complemented by additional seminars.

  7. Dynamic optical aberration correction with adaptive coded apertures techniques in conformal imaging

    Science.gov (United States)

    Li, Yan; Hu, Bin; Zhang, Pengbin; Zhang, Binglong

    2015-02-01

    Conformal imaging systems are confronted with dynamic aberration in optical design processing. In classical optical designs, for combination high requirements of field of view, optical speed, environmental adaption and imaging quality, further enhancements can be achieved only by the introduction of increased complexity of aberration corrector. In recent years of computational imaging, the adaptive coded apertures techniques which has several potential advantages over more traditional optical systems is particularly suitable for military infrared imaging systems. The merits of this new concept include low mass, volume and moments of inertia, potentially lower costs, graceful failure modes, steerable fields of regard with no macroscopic moving parts. Example application for conformal imaging system design where the elements of a set of binary coded aperture masks are applied are optimization designed is presented in this paper, simulation results show that the optical performance is closely related to the mask design and the reconstruction algorithm optimization. As a dynamic aberration corrector, a binary-amplitude mask located at the aperture stop is optimized to mitigate dynamic optical aberrations when the field of regard changes and allow sufficient information to be recorded by the detector for the recovery of a sharp image using digital image restoration in conformal optical system.

  8. Transmission Techniques for Ultra Dense Wavelength Division Multiplexing By Using Two Optical Amplifiers in Nonlinear Optical Networks

    Directory of Open Access Journals (Sweden)

    Abd El-Naser A. Mohammed

    2010-09-01

    Full Text Available In the present paper, the problem amplification techniques of ultra dense wavelength division multiplexing (UDWDM in nonlinear optical networks are investigated through five transmission techniques. The impact of tailoring of chirped pulses of different temporal waveforms is investigated in a normal dispersion fiber. The set of multiplexed signals are tailored in a different a subset to assure approximately the same output level of power to hold the signal-to-noise ratio at the same level. Moreover, three different transmission techniques, namely, soliton propagation, maximum time division multiplexing (MTDM and ìShannonî capacity, are employed where successive section of alternating dispersion are used as a technique to manage the dispersion. Distributed ìRamanî amplifiers as well as Erbium doped fiber amplifier are engaged to maximize the repeater spacing. We have succeeded to multiplex 2400 (UDWDM channels in the optical range 1.45  1.65 µm with channel spacing ranging from 0.3 up to 0.6 nm where each channel has its own characteristic parameters of loss, dispersion, and amplification. The channels are divided into sub-groups ( each of 4, 5, 6, 7,Ö.,24 where the technique of space division multiplexing (SDM is applied. The multispan effects of ìKerrî nonlinearity and amplifier noise on ìShannonî channel capacity of dispersion-free nonlinear fiber is considered as a ceiling value for the sake of comparison. The case of soliton with modified Raman amplification via parametric gain also is investigated. Each link has special chemical structure, optical signals power, and optical Raman pumping. The cable contains {4, 5, 6, 7,Ö. , 24} links in SDM. It has been shown that the modified Raman gain yields higher effects on the variable under consideration if compared with the conventional Raman gain. The number of links is in positive correlations with the set of effects {Repeater spacing, Soliton product, MTDM product}. In general

  9. Review on Sol-Gel Derived Coatings:Process, Techniques and Optical Applications

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Sol-gel process is one of the simplest techniques to manufacture thin films. The quality of the prepared films depends on the parameters of the sol-gel process and the used technique for deposition. A great variety of the sol-gel derived films have been prepared for different applications. We present a review on the sol-gel derived coatings. The description of the process is introduced in details. Different sol-gel deposition techniques are mentioned. The optical applications of the sol-gel derived coatings are reviewed.

  10. A new demodulation technique for optical fiber interferometric sensors with [3×3] directional couplers

    Institute of Scientific and Technical Information of China (English)

    Tingting Liu; Jie Cui; Desheng Chen; Ling Xiao; Dexing Sun

    2008-01-01

    2Optical fiber interferometric sensors based on [3 × 3] couplers have been used in many fields. A new technique is proposed to demodulate output signals of this kind of sensors. The technique recovers the signal of interest by fitting coefficients of elliptic (Lissajous) curves between each fiber pair. Different from other approaches, this technique eliminates the dependence on the idealization of [3 × 3] coupler, provides enhanced tolerance to the variance of photoelectric converters, and is anti-polarization in a certain extent. The main algorithm has been successfully demonstrated both by numerical simulation and experimental result.

  11. Flipped-Exponential Nyquist Pulse Technique to Optimize PAPR in Optical Direct-Detection OFDM Systems

    Institute of Scientific and Technical Information of China (English)

    Jiangnan Xiao; Zizheng Cao; Fan Li; Jin Tang; Lin Chen

    2012-01-01

    In this paper, we describe a novel technique based on the flipped-exponential (FE) Nyquist pulse method for reducing peak-to-average power ratio (PAPR) in an optical direct-detection orthogonal frequency-division multiplexing (DD-QFDM) system, The technique involves proper selection of the FE Nyquist pulses for shaping the different subcarriers of the OFDM. We apply this technique to a DD-OFDM transmission system to significantly reduce PAPR. We also investigate the sensitivity of a received OFDM signal with strong nonlinearity in a standard single-mode fiber (SMF).

  12. Finite-difference time-domain-based optical microscopy simulation of dispersive media facilitates the development of optical imaging techniques

    Science.gov (United States)

    Zhang, Di; Capoglu, Ilker; Li, Yue; Cherkezyan, Lusik; Chandler, John; Spicer, Graham; Subramanian, Hariharan; Taflove, Allen; Backman, Vadim

    2016-06-01

    Combining finite-difference time-domain (FDTD) methods and modeling of optical microscopy modalities, we previously developed an open-source software package called Angora, which is essentially a "microscope in a computer." However, the samples being simulated were limited to nondispersive media. Since media dispersions are common in biological samples (such as cells with staining and metallic biomarkers), we have further developed a module in Angora to simulate samples having complicated dispersion properties, thereby allowing the synthesis of microscope images of most biological samples. We first describe a method to integrate media dispersion into FDTD, and we validate the corresponding Angora dispersion module by applying Mie theory, as well as by experimentally imaging gold microspheres. Then, we demonstrate how Angora can facilitate the development of optical imaging techniques with a case study.

  13. Optical birefringence and molecular orientation of crazed fibres utilizing the phase shifting interferometric technique

    Science.gov (United States)

    Sokkar, T. Z. N.; El-Farahaty, K. A.; El-Bakary, M. A.; Omar, E. Z.; Hamza, A. A.

    2017-09-01

    In this article, the features of the phase shifting interferometric technique were utilized to investigate the effect of the presence of crazes in both outer and inner layers on optical birefringence and molecular orientation of polypropylene fibres. The Pluta polarizing interference microscope was used as a phase shifting technique. This method includes adding a stepper motor with a control unit to the micrometer screw of the Pluta microscope. This optical system was calibrated to be used as a phase shifting interferometric technique. The advantage of this technique is that it can detect the crazes in both inner and outer layers of the sample under test. Via this method, the relation between the presence of the crazes (in both inner and outer layers) and the optical molecular orientation of polypropylene (PP) fibres was demonstrated. To clarify the role of this method, the spatial carrier frequency technique was used to show the effect of the presence of the crazes only in the outer layers on the phase distribution values and hence the structural properties of PP fibres.

  14. A study on Optical Labelling Techniques for All-Optical Networks

    DEFF Research Database (Denmark)

    Holm-Nielsen, Pablo Villanueva

    2005-01-01

    to the selected wavelength, a short label of fixed length can be added to the information flow in order to be processed in intermediate nodes. The main advantage of this approach is the ability to route packets or bursts independently of bit-rate, packet format and packet length, increasing network flexibility...... labelling schemes will be investigated with regard to generation, transmission, wavelength conversion and label swapping. The resulting subsystems are then combined in order to emulate the functionalities of a network node within a transmission system. The two main addressed labelling schemes are the IM...... of an intermediate wavelength between label erasure and label insertion. The above mentioned functionalities are assembled in whole network systems experiments that validates the different labelling schemes with respect to transmission, wavelength conversion, label swapping and retransmission. Optical labelling...

  15. Adaptive simultaneous algebraic reconstruction technique for retrieving refractive index profiles of optical fiber

    Science.gov (United States)

    Chang, Zheng; Huang, Sujuan; Wang, Tingyun; Shang, Yi; Zhang, Qianwu; Yan, Cheng; Zou, Fang

    2016-09-01

    An efficient adaptive simultaneous algebraic reconstruction technique (ASART) to calculate optical fiber refractive index profiles is proposed based on phase difference curves obtained by digital holography technique. We develop adaptive relaxation parameter (ARP) on simultaneous algebraic reconstruction technique (SART) to increase the convergence speed and improve the reconstruction accuracy. A formula of ARP is derived mathematically and multilevel scheme (MLS) is used to increase convergence speed in the first iteration. Experimental results show the proposed ASART convergences over 40% faster than SART and achieve significantly higher reconstruction accuracy. Experimental verification shows that ASART is more efficient than SART and filtered back projection in image reconstruction, especially with few projection views. The running time of ASART is much shorter than that of SART, and ASART needs fewer iteration numbers to obtain the same reconstruction effects. In addition, it can be used to measure optical fibers with various diameters that cannot be measured with S14 refractive index profiler (S14).

  16. Chopped nonlinear magneto-optic rotation: a technique for precision measurements

    CERN Document Server

    Ravishankar, Harish; Natarajan, Vasant

    2011-01-01

    We have developed a technique for precise measurement of small magnetic fields using nonlinear magneto-optic rotation (NMOR). The technique relies on the resonant laser beam being chopped. During the on time, the atoms are optically pumped into an aligned ground state ($\\Delta m=2$ coherence). During the off time, they freely precess around the magnetic field at the Larmor frequency. If the on-off modulation frequency matches (twice) the Larmor precession frequency, the rotation is resonantly enhanced in every cycle, thereby making the process like a repeated Ramsey measurement of the Larmor frequency. We study chopped-NMOR in a paraffin-coated Cs vapor cell. The out-of-phase demodulated rotation shows a Lorentzian peak of linewidth 85 $\\mu$G, corresponding to a sensitivity of 0.15 nG/$\\sqrt{{\\rm Hz}}$. We discuss the potential of this technique for the measurement of an atomic electric-dipole moment.

  17. Neutron, fluorescence, and optical imaging: An in situ combination of complementary techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, D.; Egelhaaf, S. U.; Hermes, H. E. [Condensed Matter Physics Laboratory, Heinrich Heine University, 40225 Düsseldorf (Germany); Börgardts, M.; Müller, T. J. J. [Institute for Organic and Macromolecular Chemistry, Heinrich Heine University, 40225 Düsseldorf (Germany); Grünzweig, C.; Lehmann, E. [Neutron Imaging and Activation Group, Paul Scherrer Institute, 5232 Villigen (Switzerland)

    2015-09-15

    An apparatus which enables the simultaneous combination of three complementary imaging techniques, optical imaging, fluorescence imaging, and neutron radiography, is presented. While each individual technique can provide information on certain aspects of the sample and their time evolution, a combination of the three techniques in one setup provides a more complete and consistent data set. The setup can be used in transmission and reflection modes and thus with optically transparent as well as opaque samples. Its capabilities are illustrated with two examples. A polymer hydrogel represents a transparent sample and the diffusion of fluorescent particles into and through this polymer matrix is followed. In reflection mode, the absorption of solvent by a nile red-functionalized mesoporous silica powder and the corresponding change in fluorescent signal are studied.

  18. Optical Properties of Astronomical Silicates with Infrared Techniques (OPASI-T)

    Science.gov (United States)

    Rinehart, Stephen

    2010-01-01

    Astronomical dust is observed in a variety of astrophysical environments and plays an important role in radiative processes and chemical evolution in the galaxy. Depending upon the environment, dust can be either carbon-rich or oxygen-rich (silicate grains). Both astronomical observations and ground-based data show that the optical properties of silicates can change dramatically with the crystallinity of the material, and recent laboratory research provides evidence that the optical properties of silicate dust vary as a function of temperature as well. Therefore, correct interpretation of a vast array of astronomical data relies on the understanding of the properties of silicate dust as functions of wavelength, temperature, and crystallinity. The OPASI-T (Optical Properties of Astronomical Silicates with Infrared Techniques) project addresses the need for high quality optical characterization of metal-enriched silicate condensates using a variety of techniques. A combination of both new and established experiments are used to measure the extinction, reflection, and emission properties of amorphous silicates across the infrared (near infrared to millimeter wavelengths), providing a comprehensive data set characterizing the optical parameters of dust samples. We present room temperature measurements and the experimental apparatus to be used to investigate and characterize additional metal-silicate materials.

  19. Fast in vivo bioluminescence tomography using a novel pure optical imaging technique

    Directory of Open Access Journals (Sweden)

    Shuang Zhang

    2017-05-01

    Full Text Available Bioluminescence tomography (BLT is a novel optical molecular imaging technique that advanced the conventional planar bioluminescence imaging (BLI into a quantifiable three-dimensional (3D approach in preclinical living animal studies in oncology. In order to solve the inverse problem and reconstruct tumor lesions inside animal body accurately, the prior structural information is commonly obtained from X-ray computed tomography (CT. This strategy requires a complicated hybrid imaging system, extensive post imaging analysis and involvement of ionizing radiation. Moreover, the overall robustness highly depends on the fusion accuracy between the optical and structural information. Here, we present a pure optical bioluminescence tomographic (POBT system and a novel BLT workflow based on multi-view projection acquisition and 3D surface reconstruction. This method can reconstruct the 3D surface of an imaging subject based on a sparse set of planar white-light and bioluminescent images, so that the prior structural information can be offered for 3D tumor lesion reconstruction without the involvement of CT. The performance of this novel technique was evaluated through the comparison with a conventional dual-modality tomographic (DMT system and a commercialized optical imaging system (IVIS Spectrum using three breast cancer xenografts. The results revealed that the new technique offered comparable in vivo tomographic accuracy with the DMT system (P>0.05 in much shorter data analysis time. It also offered significantly better accuracy comparing with the IVIS system (P<0.04 without sacrificing too much time.

  20. A Novel Technique of Measuring SOA Differential Carrier Lifetime and a -Factor Using SOA Optical Modulation Response

    Institute of Scientific and Technical Information of China (English)

    Ki-Hyuk Lee; Woo-Young Choi

    2003-01-01

    We demonstrate a new technique of measuring differential carrier lifetime and linewidth enhancement factor in a semiconductor optical amplifier. In our method, the optical responses and fiber transfer functions of a self-gain modulated SOA are measured and, from these, values of carrier lifetimes and linewidth enhancement factors are determined for various SOA input optical powers.

  1. A scheme to expand the delay-bandwidth product in the resonator-based delay lines by optical OFDM technique

    DEFF Research Database (Denmark)

    Zhu, Jiangbo; Tao, Li; Zhang, Ziran

    2013-01-01

    We propose a novel scheme to expand the inherent limit in the product of the optical delay and the transmission bandwidth in resonator-based delay lines, with the optical orthogonal frequency division multiplexing (OOFDM) technique. The optical group delay properties of a single ring resonator we...

  2. A signal separation technique for sub-cellular imaging using dynamic optical coherence tomography

    CERN Document Server

    Ammari, Habib; Shi, Cong

    2016-01-01

    This paper aims at imaging the dynamics of metabolic activity of cells. Using dynamic optical coherence tomography, we introduce a new multi-particle dynamical model to simulate the movements of the collagen and the cell metabolic activity and develop an efficient signal separation technique for sub-cellular imaging. We perform a singular-value decomposition of the dynamic optical images to isolate the intensity of the metabolic activity. We prove that the largest eigenvalue of the associated Casorati matrix corresponds to the collagen. We present several numerical simulations to illustrate and validate our approach.

  3. Prism coupling technique investigation of elasto-optical properties of thin polymer films

    Science.gov (United States)

    Ay, Feridun; Kocabas, Askin; Kocabas, Coskun; Aydinli, Atilla; Agan, Sedat

    2004-12-01

    The use of thin polymer films in optical planar integrated optical circuits is rapidly increasing. Much interest, therefore, has been devoted to characterizing the optical and mechanical properties of thin polymer films. This study focuses on measuring the elasto-optical properties of three different polymers; polystyrene, polymethyl-methacrylate, and benzocyclobutane. The out-of-plane elastic modulus, refractive index, film thickness, and birefringence of thin polymer films were determined by means of the prism coupling technique. The effect of the applied stress on the refractive index and birefringence of the films was investigated. Three-dimensional finite element method analysis was used so as to obtain the principal stresses for each polymer system, and combining them with the stress dependent refractive index measurements, the elasto-optic coefficients of the polymer films were determined. It was found that the applied stress in the out-of-plane direction of the thin films investigated leads to negative elasto-optic coefficients, as observed for all the three thin polymer films.

  4. A Study of the Key Techniques of High-Speed Optical Time Division Multiplexing Systems

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    @@Several key techniques in high-speed optical time division multiplexing (OTDM) systems, including the generation and compression of gain-switched picosecond optical pulses, the all optical demultiplexer based on a nonlinear optical loop mirror (NOLM), terahertz optical asymmetric demultiplexer (TOAD) and the electroabsorption modulator in OTDM systems, are studied in this dissertation. The gain-switching characteristics and the nonlinear dynamics of a semiconductor laser are investigated by solving its single-mode rate equations numerically, highlighting the dependence of the pulse width and the peak power of a gain-switched pulse on the parameters such as the differential gain and the photon lifetime, and the effects of the DC bias current and the modulation current of the laser on the pulse width and the spectral width of the gain-switched pulse. The two-dimensional bifurcation diagram is computed in a large modulation current and modulation frequency range, and it is found that the low-frequency period doubling (multipling) and chaos region are not closed fully and outspread to the high modulation current direction with a narrow modulation frequency region. In addition, a new clock recovery scheme employing the period multipling is proposed. Besides compressing the gain-switched laser diode pulse can be compressed to 6.9ps by using this DILM compressor, and such a short pulse completely satisfies the requirement for a 40 Gbit/s optical time division multiplexing (OTDM) system.

  5. Dynamic optical breast imaging: A novel technique to detect and characterize tumor vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, Laure S. [Universite Paris Descartes, Hopital Europeen Georges Pompidou, Radiology Department, 20 rue Leblanc, 75015 Paris (France); University Paris Descartes, Faculte de Medecine, EA4062, Laboratoire de Recherche en Imagerie, site Necker, 156 rue de Vaugirard, 75015 Paris (France)], E-mail: laure.fournier@gmail.com; Vanel, Daniel; Athanasiou, Alexandra [Institut Gustave-Roussy, Radiology Department, 39 rue Camille Desmoulins, 94805 Villejuif (France); Gatzemeier, Wolfgang [Division of Breast Surgery, Fondazione Salvatore Maugeri, Pavia (Italy); Masuykov, I.V. [DOBI Medical International Inc, Mahwah, NJ (United States); Padhani, Anwar R. [Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood (United Kingdom); Dromain, Clarisse [Institut Gustave-Roussy, Radiology Department, 39 rue Camille Desmoulins, 94805 Villejuif (France); Galetti, Ken [Division of Breast Surgery, Fondazione Salvatore Maugeri, Pavia (Italy); Sigal, Robert [Institut Gustave-Roussy, Radiology Department, 39 rue Camille Desmoulins, 94805 Villejuif (France); Costa, Alberto [Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood (United Kingdom); Balleyguier, Corinne [Institut Gustave-Roussy, Radiology Department, 39 rue Camille Desmoulins, 94805 Villejuif (France)

    2009-01-15

    Purpose: To prospectively determine the diagnostic accuracy of optical absorption imaging in patients with Breast Imaging Reporting and Data System (BI-RADS) 3-5 breast lesions. Materials and methods: Forty-six patients with BI-RADS classification 3 (11%), 4 (44%) or 5 (44%) lesions, underwent a novel optical imaging examination using red light to illuminate the breast. Pressure was applied on the breast, and time-dependent curves of light absorption were recorded. Curves that consistently increased or decreased over time were classified as suspicious for malignancy. All patients underwent a core or surgical biopsy. Results: Optical mammography showed a statistical difference in numbers of suspect pixels between benign (N = 12) and malignant (N = 35) lesions (respectively 1325 vs. 3170, P = 0.002). In this population, optical imaging had a sensitivity of 74%, specificity of 92%, and diagnostic accuracy of 79%. The optical signal did not vary according to any other parameter including breast size or density, age, hormonal status or histological type of lesions. Conclusion: Optical imaging is a low-cost, non-invasive technique, yielding physiological information dependent on breast blood volume and oxygenation. It appears to have a good potential for discriminating benign from malignant lesions. Further studies are warranted to define its potential role in breast cancer imaging.

  6. Radio frequency phototube and optical clock: High resolution, high rate and highly stable single photon timing technique

    Energy Technology Data Exchange (ETDEWEB)

    Margaryan, Amur

    2011-10-01

    A new timing technique for single photons based on the radio frequency phototube and optical clock or femtosecond optical frequency comb generator is proposed. The technique has a 20 ps resolution for single photons, is capable of operating with MHz frequencies and achieving 10 fs instability level.

  7. Synthesis, structural, optical, thermal and dielectric studies on new organic nonlinear optical crystal by solution growth technique.

    Science.gov (United States)

    Prakash, M; Geetha, D; Lydia Caroline, M

    2013-04-15

    Single crystals of L-phenylalanine-benzoic acid (LPBA) were successfully grown from aqueous solution by solvent evaporation technique. Purity of the crystals was increased by the method of recrystallization. The XRD analysis confirms that the crystal belongs to the monoclinic system with noncentrosymmetric space group P21. The chemical structure of compound was established by FT-NMR technique. The presence of functional groups was estimated qualitatively by Fourier transform infrared analysis (FT-IR). Ultraviolet-visible spectral analyses showed that the crystal has low UV cut-off at 254 nm combined with very good transparency of 90% in a wide range. The optical band gap was estimated to be 6.91 eV. Thermal behavior has been studied with TGA/DTA analyses. The existence of second harmonic generation (SHG) efficiency was found to be 0.56 times the value of KDP. The dielectric behavior of the sample was also studied for the first time.

  8. Techniques of surface optical breakdown prevention for low-depths femtosecond waveguides writing

    Science.gov (United States)

    Bukharin, M. A.; Skryabin, N. N.; Ganin, D. V.; Khudyakov, D. V.; Vartapetov, S. K.

    2016-08-01

    We demonstrated technique of direct femtosecond waveguide writing at record low depth (2-15 μm) under surface of lithium niobate, that play a key role in design of electrooptical modulators with low operating voltage. To prevent optical breakdown of crystal surface we used high numerical aperture objectives for focusing of light and non-thermal regime of inscription in contrast to widespread femtosecond writing technique at depths of tens micrometers or higher. Surface optical breakdown threshold was measured for both x- and z- cut crystals. Inscribed waveguides were examined for intrinsic microstructure. It also reported sharp narrowing of operating pulses energy range with writing depth under the surface of crystal, that should be taken in account when near-surface waveguides design. Novelty of the results consists in reduction of inscription depth under the surface of crystals that broadens applications of direct femtosecond writing technique to full formation of near-surface waveguides and postproduction precise geometry correction of near-surfaces optical integrated circuits produced with proton-exchanged technique.

  9. Image reconstruction using wavelet multi-resolution technique for time-domain diffuse optical tomography

    Science.gov (United States)

    Yang, Fang; Gao, Feng; Jiao, Yuting; Zhao, Huijuan

    2010-02-01

    It is generally believed that the inverse problem in diffuse optical tomography (DOT) is highly ill-posed and its solution is always under-determined and sensitive to noise, which is the main problem in the application of DOT. In this paper, we propose a method on image reconstruction for time-domain diffuse optical tomography based on panel detection and Finite-Difference Method, and introduce an approach to reduce the number of unknown parameters in the reconstruction process. We propose a multi-level scheme to reduce the number of unknowns by parameterizing the spatial distribution of optical properties via wavelet transform and then reconstruct the coefficients of this transform. Compared with previous traditional uni-level full spatial domain algorithm, this method can efficiently improve the reconstruction quality. Numerical simulations show that wavelet-based multi-level inversion is superior to the uni-level algebraic reconstruction technique.

  10. Magnetic and optical properties of the nickel thin film deposited by GLAD technique

    Directory of Open Access Journals (Sweden)

    Potočnik Jelena M.

    2014-01-01

    Full Text Available In this work, nickel thin film was deposited on glass sample using Glancing Angle Deposition (GLAD technique, to a thickness of 1 μm. Glass sample was positioned 15 degrees with respect to the nickel vapor flux. The nickel thin film was characterized by Atomic Force Microscopy (AFM, Magneto- Optical Kerr effect Microscopy and Spectroscopic Ellipsometry. According to an AFM cross-section imaging, it was found that the nickel thin film has a columnar structure. The values of the coercively, obtained from the magnetic hysteresis loops, were analyzed as a function of the sample rotation in the magnetic field. It was found that the direction of magnetization easy axis lies toward the structure growth. Optical properties of the nickel thin film were studied at the wavelength of 455 nm. From the shape of the refractive index and the extinction coefficient diagrams could be concluded that the nickel thin film has an optical anisotropy.

  11. Application of Distributed Optical Fiber Sensing Technique in Monitoring the Ground Deformation

    Directory of Open Access Journals (Sweden)

    Jin Liu

    2017-01-01

    Full Text Available The monitoring of ground deformation is important for the prevention and control of geological disaster including land subsidence, ground fissure, surface collapse, and landslides. In this study, a distributed optical fiber sensing technique based on Brillouin Optical Time-Domain Analysis (BOTDA was used to monitor the ground deformation. The principle behind the BOTDA is first introduced, and then laboratory calibration test and physical model test were carried out. Finally, BOTDA-based monitoring of ground fissure was carried out in a test site. Experimental results show that the distributed optical fiber can measure the soil strain during ground deformation process, and the strain curve responded to the soil compression and tension region clearly. During field test in Wuxi City, China, the ground fissures deformation area was monitored accurately and the trend of deformation can also be achieved to forecast and warn against the ground fissure hazards.

  12. A simple technique based on a single optical trap for the determination of bacterial swimming pattern.

    Directory of Open Access Journals (Sweden)

    Ignacio A Martínez

    Full Text Available Bacterial motility is associated to a wide range of biological processes and it plays a key role in the virulence of many pathogens. Here we describe a method to distinguish the dynamic properties of bacteria by analyzing the statistical functions derived from the trajectories of a bacterium trapped by a single optical beam. The approach is based on the model of the rotation of a solid optically trapped sphere. The technique is easily implemented in a biological laboratory, since with only a small number of optical and electronic components a simple biological microscope can be converted into the required analyzer. To illustrate the functionality of this method, we probed several Salmonella enterica serovar Typhimurium mutants that differed from the wild-type with respect to their swimming patterns. In a further application, the motility dynamics of the S. Typhimurium cheV mutant were characterized.

  13. Nonlinear optical properties of natural laccaic acid dye studied using Z-scan technique

    Science.gov (United States)

    Zongo, S.; Sanusi, K.; Britton, J.; Mthunzi, P.; Nyokong, T.; Maaza, M.; Sahraoui, B.

    2015-08-01

    We have investigated the nonlinear optical properties, including the optical limiting behaviour for five different concentrations of laccaic acid dye in solution and a thin film obtained through doping in poly (methyl methacrylate) (PMMA) polymer. The experiments were performed by using single beam Z-scan technique at 532 nm with 10 ns, 10 Hz Nd:YAG laser pulses excitation. From the open-aperture Z-scan data, we derived that the laccaic dye samples exhibit strong two photon absorption (2PA). The nonlinear refractive index was determined through the closed aperture Z-scan data. The estimated absorption coefficient β2, nonlinear refractive index n2 and second order hyperpolarizability γ were found to be of the order of 10-10 m/W, 10-9 esu and 10-32 esu, respectively. The Z-scan study reveals that the natural laccaic acid dye emerges as a promising material for third order nonlinear optical devices application.

  14. Optical characteristics of transparent samarium oxide thin films deposited by the radio-frequency sputtering technique

    Indian Academy of Sciences (India)

    A A ATTA; M M EL-NAHASS; KHALED M ELSABAWY; M M ABD EL-RAHEEM; A M HASSANIEN; A ALHUTHALI; ALI BADAWI; AMAR MERAZGA

    2016-11-01

    Transparent metal oxide thin films of samarium oxide (Sm$_2$O$_3$) were prepared on pre-cleaned fused optically flat quartz substrates by radio-frequency (RF) sputtering technique. The as-deposited thin films were annealed at different temperatures (873, 973 and 1073 K) for 4 h in air under normal atmospheric pressure. The topological morphology of the film surface was characterized by using atomic force microscopy (AFM). The optical properties of the as-prepared and annealed thin films were studied using their reflectance and transmittance spectra at nearly normal incident light. The estimated direct optical band gap energy (E$^{d}_{g}$ ) values were found to increase by increasing the annealing temperatures. The dispersion curves of the refractive index of Sm$_2$O$_3$ thin films were found to obey the single oscillator model.

  15. A Single Shot, Sub-picosecond Beam Bunch Characterization with Electro-optic Techniques

    CERN Document Server

    Semertzidis, Y K; Castillo, V; Larsen, R; Lazarus, D M; Nikas, D; Ozben, C; Srinivasan-Rao, T; Stillman, A; Tsang, Thomas; Kowalski, L A

    2001-01-01

    In the past decade, the bunch lengths of electrons in accelerators have decreased dramatically to the range of a few picoseconds \\cite{Uesaka94,Trotz97}. Measurement of the length as well as the longitudinal profile of these short bunches have been a topic of research in a number of institutions \\cite{Uesaka97,Liu97,Hutchins00}. One of the techniques uses the electric field induced by the passage of electrons in the vicinity of a birefringent crystal to change its optical characteristics. Well-established electro-optic techniques can then be used to measure the temporal characteristics of the electron bunch. In this paper we present a novel, non-invasive, single-shot approach to improve the resolution to tens of femtoseconds so that sub-millimeter bunch length can be measured.

  16. Optical sensing of peroxide using ceria nanoparticles via fluorescence quenching technique

    Science.gov (United States)

    Shehata, Nader; Samir, Effat; Gaballah, Soha; Salah, Mohammed

    2016-07-01

    This study introduces the application of ceria nanoparticles (NPs) as an optical sensor for peroxide using fluorescence quenching technique. Our synthesized ceria NPs have the ability to adsorb peroxides via its oxygen vacancies. Ceria NPs solution with added variable concentrations of hydrogen peroxides is exposed through near-UV excitation and the detected visible fluorescent emission is found to be at ˜520 nm. The fluorescent intensity peak is found to be reduced with increasing the peroxide concentrations due to static fluorescence quenching technique. The relative intensity change of the visible fluorescent emission has been reduced to more than 50% at added peroxide concentrations up to 10 wt. %. In order to increase ceria peroxides sensing sensitivity, lanthanide elements such as samarium (Sm) are used as ceria NPs dopant. This research work could be applied further in optical sensors of radicals in biomedical engineering and environmental monitoring.

  17. Vibration measurement based on the optical cross-correlation technique with femtosecond pulsed laser

    Science.gov (United States)

    Han, Jibo; Wu, Tengfei; Zhao, Chunbo; Li, Shuyi

    2016-10-01

    Two vibration measurement methods with femtosecond pulsed laser based on the optical cross-correlation technique are presented independently in this paper. The balanced optical cross-correlation technique can reflect the time jitter between the reference pluses and measurement pluses by detecting second harmonic signals using type II phase-matched nonlinear crystal and balanced amplified photo-detectors. In the first method, with the purpose of attaining the vibration displacement, the time difference of the reference pulses relative to the measurement pluses can be measured using single femtosecond pulsed laser. In the second method, there are a couple of femtosecond pulsed lasers with high pulse repetition frequency. Vibration displacement associated with cavity length can be calculated by means of precisely measuring the pulse repetition frequency. The results show that the range of measurement attains ±150μm for a 500fs pulse. These methods will be suited for vibration displacement measurement, including laboratory use, field testing and industrial application.

  18. An Approximate Numerical Technique for Characterizing Optical Pulse Propagation in Inhomogeneous Biological Tissue

    Directory of Open Access Journals (Sweden)

    Chintha C. Handapangoda

    2008-01-01

    Full Text Available An approximate numerical technique for modeling optical pulse propagation through weakly scattering biological tissue is developed by solving the photon transport equation in biological tissue that includes varying refractive index and varying scattering/absorption coefficients. The proposed technique involves first tracing the ray paths defined by the refractive index profile of the medium by solving the eikonal equation using a Runge-Kutta integration algorithm. The photon transport equation is solved only along these ray paths, minimizing the overall computational burden of the resulting algorithm. The main advantage of the current algorithm is that it enables to discretise the pulse propagation space adaptively by taking optical depth into account. Therefore, computational efficiency can be increased without compromising the accuracy of the algorithm.

  19. An optical authentication system based on encryption technique and multimodal biometrics

    Science.gov (United States)

    Yuan, Sheng; Zhang, Tong; Zhou, Xin; Liu, Xuemei; Liu, Mingtang

    2013-12-01

    A major concern nowadays for a biometric credential management system is its potential vulnerability to protect its information sources. To prevent a genuine user's templates from both internal and external threats, a novel and simple method combined optical encryption with multimodal biometric authentication technique is proposed. In this method, the standard biometric templates are generated real-timely by the verification keys owned by legal user so that they are unnecessary to be stored in a database. Compared with the traditional recognition algorithms, storage space and matching time are greatly saved. In addition, the verification keys are difficult to be forged due to the utilization of optical encryption technique. Although the verification keys are lost or stolen, they are useless for others in absence of the legal owner's biometric. A series of numerical simulations are performed to demonstrate the feasibility and performance of this method.

  20. A novel noninvasive all optical technique to monitor physiology of an exercising muscle

    Science.gov (United States)

    Saxena, Vishal; Marcu, Laura; Karunasiri, Gamani

    2008-11-01

    An all optical technique based on near-infrared spectroscopy and mid-infrared imaging (MIRI) is applied as a noninvasive, in vivo tool to monitor the vascular status of skeletal muscle and the physiological changes that occur during exercise. A near-infrared spectroscopy (NIRS) technique, namely, steady state diffuse optical spectroscopy (SSDOS) along with MIRI is applied for monitoring the changes in the values of tissue oxygenation and thermometry of an exercising muscle. The NIRS measurements are performed at five discrete wavelengths in a spectral window of 650-850 nm and MIRI is performed in a spectral window of 8-12 µm. The understanding of tissue oxygenation status and the behavior of the physiological parameters derived from thermometry may provide a useful insight into muscle physiology, therapeutic response and treatment.

  1. Fiber-optic parametric amplifier and oscillator based on intracavity parametric pump technique.

    Science.gov (United States)

    Luo, Zhengqian; Zhong, Wen-De; Tang, Ming; Cai, Zhiping; Ye, Chenchun; Xiao, Xiaosheng

    2009-01-15

    A cost-effective fiber optical parametric amplifier (FOPA) based on the laser intracavity pump technique has been proposed and demonstrated experimentally. The parametric process is realized by inserting a 1 km highly nonlinear dispersion-shifted fiber (HNL-DSF) into a fiber ring-laser cavity that consists of a high-power erbium-doped fiber (EDF) amplifier and two highly reflective fiber Bragg gratings. Compared with the conventional parametric pump schemes, the proposed pumping technique is free from a tunable semiconductor laser as the pump source and also the pump phase modulation. When the oscillating power of 530 mW in the EDF laser cavity is achieved to pump the HNL-DSF, a peak parametric gain of 27.5 dB and a net gain over 45 nm are obtained. Moreover, a widely tunable fiber-optic parametric oscillator is further developed using the FOPA as a gain medium.

  2. Optical and Thermal Analysis of the Time Evolution of Curing in Resins by Photothermal Techniques

    Science.gov (United States)

    Martínez-Torres, P.; Zambrano-Arjona, M.; Aguilar, G.; Alvarado-Gil, J. J.

    2012-11-01

    Four shades of a commercial visible-light curing dental resin are analyzed using photothermal techniques. The thermal effusivities of the dental resin shades before curing are measured using a variant of the conventional photoacoustic technique. The thermal diffusivities before and after curing are measured using infrared photothermal radiometry in the forward emission configuration. The time evolution process of the photocuring resin is monitored by photothermal radiometry in the forward and backward emission configurations. Inversion of the time evolution signal of the different configurations used permits one to obtain the time evolution of the thermal and optical properties during the photocuring. The thermal effusivity and thermal diffusivity exhibit exponential growth, while the optical absorption decreases exponentially due to the curing process. The relationship of these phenomena with the decrease of monomer concentration induced by the curing is discussed.

  3. [Research on the blood components detecting by multi-optical path length spectroscopy technique].

    Science.gov (United States)

    Li, Gang; Zhao, Zhe; Liu, Rui; Wang, Hui-quan; Wu, Hong-jie; Lin, Ling

    2010-09-01

    To discuss the feasibility of using the serum's multi-optical path length spectroscopy information for measuring the concentration of the human blood components, the automatic micro-displacement measuring device was designed, which can obtain the near-infrared multi-optical path length from 0 to 4.0 mm (interval is 0.2 mm) spectra of 200 serum samples with multioptical path length spectrum of serum participated in building the quantitative analysis model of four components of the human blood: glucose (GLU), total cholesterol (TC), total protein (TP) and albumin (ALB), by mean of the significant non-linear spectral characteristic of blood. Partial least square (PLS) was used to set up the calibration models of the multi-optical path length near-infrared absorption spectrum of 160 experimental samples against the biochemical analysis results of them. The blood components of another 40 samples were predicted according to the model. The prediction effect of four blood components was favorable, and the correlation coefficient (r) of predictive value and biochemical analysis value were 0.9320, 0.9712, 0.9462 and 0.9483, respectively. All of the results proved the feasibility of the multi-optical path length spectroscopy technique for blood components analysis. And this technique established the foundation of detecting the components of blood and other liquid conveniently and rapidly.

  4. Integrating Nanostructured Artificial Receptors with Whispering Gallery Mode Optical Microresonators via Inorganic Molecular Imprinting Techniques.

    Science.gov (United States)

    Hammond, G Denise; Vojta, Adam L; Grant, Sheila A; Hunt, Heather K

    2016-06-15

    The creation of label-free biosensors capable of accurately detecting trace contaminants, particularly small organic molecules, is of significant interest for applications in environmental monitoring. This is achieved by pairing a high-sensitivity signal transducer with a biorecognition element that imparts selectivity towards the compound of interest. However, many environmental pollutants do not have corresponding biorecognition elements. Fortunately, biomimetic chemistries, such as molecular imprinting, allow for the design of artificial receptors with very high selectivity for the target. Here, we perform a proof-of-concept study to show how artificial receptors may be created from inorganic silanes using the molecular imprinting technique and paired with high-sensitivity transducers without loss of device performance. Silica microsphere Whispering Gallery Mode optical microresonators are coated with a silica thin film templated by a small fluorescent dye, fluorescein isothiocyanate, which serves as our model target. Oxygen plasma degradation and solvent extraction of the template are compared. Extracted optical devices are interacted with the template molecule to confirm successful sorption of the template. Surface characterization is accomplished via fluorescence and optical microscopy, ellipsometry, optical profilometry, and contact angle measurements. The quality factors of the devices are measured to evaluate the impact of the coating on device sensitivity. The resulting devices show uniform surface coating with no microstructural damage with Q factors above 10⁶. This is the first report demonstrating the integration of these devices with molecular imprinting techniques, and could lead to new routes to biosensor creation for environmental monitoring.

  5. Integrating Nanostructured Artificial Receptors with Whispering Gallery Mode Optical Microresonators via Inorganic Molecular Imprinting Techniques

    Directory of Open Access Journals (Sweden)

    G. Denise Hammond

    2016-06-01

    Full Text Available The creation of label-free biosensors capable of accurately detecting trace contaminants, particularly small organic molecules, is of significant interest for applications in environmental monitoring. This is achieved by pairing a high-sensitivity signal transducer with a biorecognition element that imparts selectivity towards the compound of interest. However, many environmental pollutants do not have corresponding biorecognition elements. Fortunately, biomimetic chemistries, such as molecular imprinting, allow for the design of artificial receptors with very high selectivity for the target. Here, we perform a proof-of-concept study to show how artificial receptors may be created from inorganic silanes using the molecular imprinting technique and paired with high-sensitivity transducers without loss of device performance. Silica microsphere Whispering Gallery Mode optical microresonators are coated with a silica thin film templated by a small fluorescent dye, fluorescein isothiocyanate, which serves as our model target. Oxygen plasma degradation and solvent extraction of the template are compared. Extracted optical devices are interacted with the template molecule to confirm successful sorption of the template. Surface characterization is accomplished via fluorescence and optical microscopy, ellipsometry, optical profilometry, and contact angle measurements. The quality factors of the devices are measured to evaluate the impact of the coating on device sensitivity. The resulting devices show uniform surface coating with no microstructural damage with Q factors above 106. This is the first report demonstrating the integration of these devices with molecular imprinting techniques, and could lead to new routes to biosensor creation for environmental monitoring.

  6. Machine learning techniques for astrophysical modelling and photometric redshift estimation of quasars in optical sky surveys

    CERN Document Server

    Kumar, N Daniel

    2008-01-01

    Machine learning techniques are utilised in several areas of astrophysical research today. This dissertation addresses the application of ML techniques to two classes of problems in astrophysics, namely, the analysis of individual astronomical phenomena over time and the automated, simultaneous analysis of thousands of objects in large optical sky surveys. Specifically investigated are (1) techniques to approximate the precise orbits of the satellites of Jupiter and Saturn given Earth-based observations as well as (2) techniques to quickly estimate the distances of quasars observed in the Sloan Digital Sky Survey. Learning methods considered include genetic algorithms, particle swarm optimisation, artificial neural networks, and radial basis function networks. The first part of this dissertation demonstrates that GAs and PSOs can both be efficiently used to model functions that are highly non-linear in several dimensions. It is subsequently demonstrated in the second part that ANNs and RBFNs can be used as ef...

  7. DSP-based optical modulation technique for long-haul transmission

    Science.gov (United States)

    Yoshida, T.; Sugihara, T.; Uto, K.

    2015-01-01

    Fiber nonlinearity and equalization-enhanced phase noise (EEPN) generate rapid perturbations and critically limit the system capacity and range of long-haul optical transmission. It is possible to cancel the rapid perturbations by introducing a particular correlation between multiple signals at the transmitter and analyzing the received signals using digital signal processing. In this paper, we review our proposed techniques to cancel rapid perturbations of polarization multiplexed signals due to fiber nonlinearity and EEPN. Numerical simulation of quaternary phase-shift keying based signals shows 1.2 dB and 0.5 dB improvement respectively from the proposed cancellation techniques for fiber nonlinearity and EEPN.

  8. Linear optical characterization of transparent thin films by the Z-scan technique.

    Science.gov (United States)

    Boudebs, Georges; Fedus, Kamil

    2009-07-20

    We report experimental characterization of a very small rectangular phase shift (Z-scan technique. The numerical simulations as well as the experimental results reveal a peak-valley configuration in the far-field normalized transmittance, allowing us to determine the sign of the dephasing. The conditions necessary to obtain useful Z-scan traces are discussed. We provide simple linear expressions relating the measured signal to the phase shift. A very good agreement between calculated and experimental Z-scan profiles validates our approach. We show that a very well known nonlinear characterization technique can be extended for linear optical parameter estimation (as refractive index or thickness).

  9. New autocorrelation technique for the IR FEL optical pulse width measurements

    Energy Technology Data Exchange (ETDEWEB)

    Amirmadhi, F.; Brau, K.A.; Becker, C. [Vanderbilt Univ., Nashville, TN (United States)] [and others

    1995-12-31

    We have developed a new technique for the autocorrelation measurement of optical pulse width at the Vanderbilt University FEL center. This method is based on nonlinear absorption and transmission characteristics of semiconductors such as Ge, Te and InAs suitable for the wavelength range from 2 to over 6 microns. This approach, aside being simple and low cost, removes the phase matching condition that is generally required for the standard frequency doubling technique and covers a greater wavelength range per nonlinear material. In this paper we will describe the apparatus, explain the principal mechanism involved and compare data which have been acquired with both frequency doubling and two-photon absorption.

  10. Comparison between optical techniques and confocal microscopy for defect detection on thin wires

    Energy Technology Data Exchange (ETDEWEB)

    Siegmann, Philip; Sanchez-Brea, Luis Miguel; Martinez-Anton, Juan Carlos; Bernabeu, Eusebio

    2004-11-15

    Conventional microscopy techniques, such as atomic force microscopy (AFM), scanning electron microscopy (SEM), and confocal microscopy (CM) are not suitable for on-line surface inspection of fine metallic wires. In the recent years, some optical techniques have been developed to be used for those tasks. However, they need a rigorous validation. In this work, we have used confocal microscopy to obtain the topography z(x,y) of wires with longitudinal defects, such as dielines. The topography has been used to predict the light scattered by the wire. These simulations have been compared with experimental results, showing a good agreement.

  11. Fluid Dynamic Analysis of Shaken and Mechanically Stirred Reactors by Means of Optical Techniques

    OpenAIRE

    Pieralisi, Irene

    2016-01-01

    This research aims at deepening the knowledge of the hydrodynamics developing within some specific mixing system configurations. In particular, a standard geometry stirred vessel, an unbaffled stirred vessel of unconventional geometry and a shaken bioreactor are studied. Optical techniques (LDA, PIV) are employed in order to obtain detailed information on the mean and turbulent characteristics of the flow developing within the different lab-scale reactors, while subsequent data analysis a...

  12. Comparison of different modelling techniques for longitudinally invariant integrated optical waveguides

    Science.gov (United States)

    de Zutter, D.; Lagasse, P.; Buus, J.; Young, T. P.; Dillon, B. M.

    1989-10-01

    In order to compare various modeling techniques for the eigenmode analysis of integrated optical waveguides, twelve different methods are applied to the analysis of two typical III-V rib waveguides. Both a single and a coupled waveguide case are considered. Results focus on the effective refractive index value for the lowest order TE-mode in the case of the single waveguide, and on the coupling length between the lowest order symmetric and antisymmetric TE-modes of the coupled waveguides.

  13. Novel Chromatic Technique Based on Optical Absorbance in Characterizing Mineral Hydraulic Oil Degradation

    OpenAIRE

    Ossia, C. V.; Kong, H

    2012-01-01

    A low cost, compact, real-time, and quick measurement optical device based on the absorbance of white light, which comprised of photodiodes in a 3-element color-sensor, feedback diodes, water and temperature sensing element, and so on, was developed and tested in low absorption mineral oil. The device, a deviation from conventional electrical, mechanical, and electrochemical techniques, uses color ratio (CR) and total contamination index (TCI) parameters based on transmitted light intensity i...

  14. Polarization-insensitive fiber optical parametric amplifier based on polarization diversity technique with dual parallel pumps

    Institute of Scientific and Technical Information of China (English)

    YIN Lu; SANG Xin-zhu; ZHANG Qi; XIN Xiang-jun; YU Chong-xiu; Da-xiong

    2011-01-01

    By analyzing the principle of dual-pump parametric amplification and the polarization dependent gain of fiber optical parametric amplifier (FOPA), a polarization-insensitive FOPA based on polarization-diversity technique with dual parallel pumps is presented. The performances of polarization-insensitivity, gain and BER are theoretically analyzed and numerically simulated by comparing the proposed scheme with parallel pump solution and orthogonal pump solution. The presented solution can reduce the complexity of state of polarization (SoP) of pumps.

  15. Study of optical techniques for the Ames unitary wind tunnel: Digital image processing, part 6

    Science.gov (United States)

    Lee, George

    1993-01-01

    A survey of digital image processing techniques and processing systems for aerodynamic images has been conducted. These images covered many types of flows and were generated by many types of flow diagnostics. These include laser vapor screens, infrared cameras, laser holographic interferometry, Schlieren, and luminescent paints. Some general digital image processing systems, imaging networks, optical sensors, and image computing chips were briefly reviewed. Possible digital imaging network systems for the Ames Unitary Wind Tunnel were explored.

  16. Calibration of an optical condensate measurement technique using indirect static headspace gas chromatography.

    Science.gov (United States)

    Hoke, P B; Loconto, P R; McGrath, J J

    2001-12-01

    Researchers in the Department of Mechanical Engineering seek to obtain a means to measure less than 3 mg of H2O that adheres to a metal surface as condensate. The objective is to calibrate optical reflectance measurements of an aluminum surface as a function of the condensate thickness present. Collaboration with the Hazardous Substance Research Center at Michigan State University results in the development of an indirect static headspace gas chromatographic technique capable of measuring H2O in low-milligram quantities. The technique utilizes manual headspace sampling, a megabore capillary column, and a flame ionization detector. A correlation of r2 = 0.999 is obtained for the calibration of the indirect measurement technique. The calibration of the analytical instrument demonstrates adequate precision (calcium carbide to convert the H2O to acetylene. A scaled calibration technique is used to simplify handling trace water volumes. The surface reflectance measurements are found to correlate well (r2 = 0.935) with measurements of the condensate mass. This result facilitates the development of an optical mass-transfer measurement technique. This study focuses on the analytical method and its relationship with engineering research.

  17. High capacity fiber optic sensor networks using hybrid multiplexing techniques and their applications

    Science.gov (United States)

    Sun, Qizhen; Li, Xiaolei; Zhang, Manliang; Liu, Qi; Liu, Hai; Liu, Deming

    2013-12-01

    Fiber optic sensor network is the development trend of fiber senor technologies and industries. In this paper, I will discuss recent research progress on high capacity fiber sensor networks with hybrid multiplexing techniques and their applications in the fields of security monitoring, environment monitoring, Smart eHome, etc. Firstly, I will present the architecture of hybrid multiplexing sensor passive optical network (HSPON), and the key technologies for integrated access and intelligent management of massive fiber sensor units. Two typical hybrid WDM/TDM fiber sensor networks for perimeter intrusion monitor and cultural relics security are introduced. Secondly, we propose the concept of "Microstructure-Optical X Domin Refecltor (M-OXDR)" for fiber sensor network expansion. By fabricating smart micro-structures with the ability of multidimensional encoded and low insertion loss along the fiber, the fiber sensor network of simple structure and huge capacity more than one thousand could be achieved. Assisted by the WDM/TDM and WDM/FDM decoding methods respectively, we built the verification systems for long-haul and real-time temperature sensing. Finally, I will show the high capacity and flexible fiber sensor network with IPv6 protocol based hybrid fiber/wireless access. By developing the fiber optic sensor with embedded IPv6 protocol conversion module and IPv6 router, huge amounts of fiber optic sensor nodes can be uniquely addressed. Meanwhile, various sensing information could be integrated and accessed to the Next Generation Internet.

  18. Photons and (artificial) atoms: an overview of optical spectroscopy techniques on quantum dots

    Science.gov (United States)

    Vamivakas, A. N.; Atatüre, M.

    2010-01-01

    In most branches within experimental physics technical prowess lies at the heart of many seminal works. From the observation of the photoelectric effect and the ultraviolet catastrophe that led to the development of quantum mechanics to the first transistor that shaped the modern age of electronics, significant physical insight has been achieved on the shoulders of technical advances and progress. Research on self-assembled quantum dots may be a drop in the sea of physics, but it still is no exception to this trend, and more physical insight continues to be revealed as the tools of the trade get increasingly more complex and advanced. This article is written primarily for senior undergraduate students and first year graduate students of experimental physics involving optically active quantum dots. More often than not, we have seen students shuffling through journal articles trying to relate the reported physics to the used experimental techniques. What we want to cover here is not in any way the history or the recent progress in quantum dot research - there are an ample number of topical books and review articles for that - but rather to highlight a selection of optics-based measurement techniques that have led to significant progress in our understanding of quantum dot physics as well as their applications in the last two decades. We hope a basic survey of the relevant optical spectroscopy techniques will help the newcomers in connecting the dots between measurements and physics.

  19. Optical coherence tomography: a non-invasive technique applied to conservation of paintings

    Science.gov (United States)

    Liang, Haida; Gomez Cid, Marta; Cucu, Radu; Dobre, George; Kudimov, Boris; Pedro, Justin; Saunders, David; Cupitt, John; Podoleanu, Adrian

    2005-06-01

    It is current practice to take tiny samples from a painting to mount and examine in cross-section under a microscope. However, since conservation practice and ethics limit sampling to a minimum and to areas along cracks and edges of paintings, which are often unrepresentative of the whole painting, results from such analyses cannot be taken as representative of a painting as a whole. Recently in a preliminary study, we have demonstrated that near-infrared Optical Coherence Tomography (OCT) can be used directly on paintings to examine the cross-section of paint and varnish layers without contact and the need to take samples. OCT is an optical interferometric technique developed for in vivo imaging of the eye and biological tissues; it is essentially a scanning Michelson's interferometer with a "broad-band" source that has the spatial coherence of a laser. The low temporal coherence and high spatial concentration of the source are the keys to high depth resolution and high sensitivity 3D imaging. The technique is non-invasive and non-contact with a typical working distance of 2 cm. This non-invasive technique enables cross-sections to be examined anywhere on a painting. In this paper, we will report new results on applying near-infrared en-face OCT to paintings conservation and extend the application to the examination of underdrawings, drying processes, and quantitative measurements of optical properties of paint and varnish layers.

  20. Optical phase distortion due to turbulent-fluid density fields - Quantification using the small-aperture beam technique

    Science.gov (United States)

    Jumper, E. J.; Hugo, R. J.

    1992-07-01

    This paper discusses the small-aperture beam technique, a relatively new way of experimentally quantifying optically-active, turbulent-fluid-flow-induced optical degradation. The paper lays out the theoretical basis for the technique, and the relationship of the measured jitter of the beam to optical path difference. A numerical simulation of a two-dimensional heated jet is used to explore the validity of beam jitter to obtain optical path difference in a flow region where eddy production constitutes the major character of the 'turbulent' flow field.

  1. Noninvasive assessment of cutaneous alterations in mice exposed to whole body gamma irradiation using optical imaging techniques.

    Science.gov (United States)

    Sharma, P; Sahu, K; Kushwaha, P K; Kumar, S; Swami, M K; Kumawat, J; Patel, H S; Kher, S; Sahani, P K; Haridas, G; Gupta, P K

    2017-07-11

    We report the results of a study carried out to investigate the potential of optical techniques such as optical coherence tomography, Mueller matrix spectroscopy, and cross-polarization imaging for noninvasive monitoring of the ionizing radiation exposure-induced alterations in cutaneous tissue of mice. Radiation dose-dependent changes were observed in tissue microvasculature and tissue optical parameters like retardance and depolarization as early as 1 h post radiation exposure. Results suggest that these optical techniques may allow early detection of radiation dose-dependent alterations which could help in screening of population exposed to radiation.

  2. Study of Rydberg blockade mediated optical non-linearity in thermal vapor using optical heterodyne detection technique

    CERN Document Server

    Bhowmick, Arup; Mohapatra, Ashok K

    2016-01-01

    We demonstrate the phenomenon of blockade in two-photon excitations to the Rydberg state in thermal vapor. A technique based on optical heterodyne is used to measure the dispersion of a probe beam far off resonant to the D2 line of rubidium in the presence of a strong laser beam that couples to the Rydberg state via two-photon resonance. Density dependent suppression of the dispersion peak is observed while coupling to the Rydberg state with principal quantum number, n = 60. The experimental observation is explained using the phenomenon of Rydberg blockade. The blockade radius is measured to be about 2.2 {\\mu}m which is consistent with the scaling due to the Doppler width of 2-photon resonance in thermal vapor. Our result promises the realization of single photon source and strong single photon non-linearity based on Rydberg blockade in thermal vapor.

  3. A novel optical investigation technique for railroad track inspection and assessment

    Science.gov (United States)

    Sabato, Alessandro; Beale, Christopher H.; Niezrecki, Christopher

    2017-04-01

    Track failures due to cross tie degradation or loss in ballast support may result in a number of problems ranging from simple service interruptions to derailments. Structural Health Monitoring (SHM) of railway track is important for safety reasons and to reduce downtime and maintenance costs. For this reason, novel and cost-effective track inspection technologies for assessing tracks' health are currently insufficient and needed. Advancements achieved in recent years in cameras technology, optical sensors, and image-processing algorithms have made machine vision, Structure from Motion (SfM), and three-dimensional (3D) Digital Image Correlation (DIC) systems extremely appealing techniques for extracting structural deformations and geometry profiles. Therefore, optically based, non-contact measurement techniques may be used for assessing surface defects, rail and tie deflection profiles, and ballast condition. In this study, the design of two camera-based measurement systems is proposed for crossties-ballast condition assessment and track examination purposes. The first one consists of four pairs of cameras installed on the underside of a rail car to detect the induced deformation and displacement on the whole length of the track's cross tie using 3D DIC measurement techniques. The second consists of another set of cameras using SfM techniques for obtaining a 3D rendering of the infrastructure from a series of two-dimensional (2D) images to evaluate the state of the track qualitatively. The feasibility of the proposed optical systems is evaluated through extensive laboratory tests, demonstrating their ability to measure parameters of interest (e.g. crosstie's full-field displacement, vertical deflection, shape, etc.) for assessment and SHM of railroad track.

  4. Robust modulation formats recognition technique using wavelet transform for high speed optical networks

    Science.gov (United States)

    Guesmi, Latifa; Hraghi, Abir; Menif, Mourad

    2015-09-01

    There is a need, for high speed optical communication networks, in the monitoring process, to determine the modulation format type of a received signal. In this paper, we present a new achievement of modulation format recognition technique, where we proposed the use of wavelet transform of the detected signal in conjunction with the artificial neural network (ANN) algorithm. Besides, wavelet transform is one of the most popular candidates of the time-frequency transformations, where the wavelets are generated from a basic wavelet function by dilations and translations. We proved that this technique is capable of recognizing the multi-carriers modulation scheme with high accuracy under different transmission impairments such as chromatic dispersion (CD), differential group delay (DGD) and accumulated amplified spontaneous emission (ASE) noise with different ranges. Both the theoretical analysis and the simulation results showed that the wavelet transform not only can be used for modulation identification of optical communication signals, but also has a better classification accuracies under appropriate OSNR (optical signal-to-noise ratio) values.

  5. Slowing techniques for loading a magneto-optical trap of CaF molecules

    Science.gov (United States)

    Truppe, Stefan; Fitch, Noah; Williams, Hannah; Hambach, Moritz; Sauer, Ben; Hinds, Ed; Tarbutt, Mike

    2016-05-01

    Ultracold molecules in a magneto-optical trap (MOT) are useful for testing fundamental physics and studying strongly-interacting quantum systems. With experiments starting with a relatively fast (50-200 m/s) buffer-gas beam, a primary concern is decelerating molecules to below the MOT capture velocity, typically 10 m/s. Direct laser cooling, where the molecules are slowed via momentum transfer from a chirped counter-propagating narrowband laser, is a natural choice. However, chirping the cooling and repump lasers requires precise control of multiple laser frequencies simultaneously. Another approach, called ``white-light slowing'' uses a broadband laser such that all fast molecules in the beam are decelerated. By addressing numerous velocities no chirping is needed. Unfortunately, both techniques have significant losses as molecules are transversely heated during the optical cycling. Ideally, the slowing method would provide simultaneous deceleration and transverse guiding. A newly developed technique, called Zeeman-Sisyphus deceleration, is potentially capable of both. Using permanent magnets and optical pumping, the number of scattered photons is reduced, lessening transverse heating and relaxing the repump requirements. Here we compare all three options for CaF.

  6. High performance optical encryption based on computational ghost imaging with QR code and compressive sensing technique

    Science.gov (United States)

    Zhao, Shengmei; Wang, Le; Liang, Wenqiang; Cheng, Weiwen; Gong, Longyan

    2015-10-01

    In this paper, we propose a high performance optical encryption (OE) scheme based on computational ghost imaging (GI) with QR code and compressive sensing (CS) technique, named QR-CGI-OE scheme. N random phase screens, generated by Alice, is a secret key and be shared with its authorized user, Bob. The information is first encoded by Alice with QR code, and the QR-coded image is then encrypted with the aid of computational ghost imaging optical system. Here, measurement results from the GI optical system's bucket detector are the encrypted information and be transmitted to Bob. With the key, Bob decrypts the encrypted information to obtain the QR-coded image with GI and CS techniques, and further recovers the information by QR decoding. The experimental and numerical simulated results show that the authorized users can recover completely the original image, whereas the eavesdroppers can not acquire any information about the image even the eavesdropping ratio (ER) is up to 60% at the given measurement times. For the proposed scheme, the number of bits sent from Alice to Bob are reduced considerably and the robustness is enhanced significantly. Meantime, the measurement times in GI system is reduced and the quality of the reconstructed QR-coded image is improved.

  7. The Optical Fractionator Technique to Estimate Cell Numbers in a Rat Model of Electroconvulsive Therapy.

    Science.gov (United States)

    Olesen, Mikkel Vestergaard; Needham, Esther Kjær; Pakkenberg, Bente

    2017-07-09

    Stereological methods are designed to describe quantitative parameters without making assumptions about size, shape, orientation and distribution of cells or structures. These methods have been revolutionary for quantitative analysis of the mammalian brain, in which volumetric cell populations are too high to count manually, and stereology is now the technique of choice whenever estimates of three-dimensional quantities need to be extracted from measurements on two-dimensional sections. All stereological methods are in principle unbiased; however, they rely on proper knowledge about the structure of interest and the characteristics of the tissue. Stereology is based on Systematic Uniformly Random Sampling (SURS), with adjustment of sampling to the most efficient level in respect to precision, providing reliable, quantitative information about the whole structure of interest. Here we present the optical fractionator in conjunction with BrdU immunohistochemistry to estimate the production and survival of newly-formed neurons in the granule cell layer (including the sub-granular zone) of the rat hippocampus following electroconvulsive stimulation, which is among the most potent stimulators of neurogenesis. The optical fractionator technique is designed to provide estimates of the total number of cells from thick sections sampled from the full structure. Thick sections provide the opportunity to observe cells in their full 3-D extent and thus, allow for easy and robust cell classification based on morphological criteria. When correctly implemented, the sensitivity and efficiency of the optical fractionator provides accurate estimates with a fixed and predetermined precision.

  8. Investigation of HIV-1 infected and uninfected cells using the optical trapping technique

    Science.gov (United States)

    Ombinda-Lemboumba, S.; Malabi, R.; Lugongolo, M. Y.; Thobakgale, S. L.; Manoto, S.; Mthunzi-Kufa, P.

    2017-02-01

    Optical trapping has emerged as an essential tool for manipulating single biological material and performing sophisticated spectroscopy analysis on individual cell. The optical trapping technique has been used to grab and immobilize cells from a tightly focused laser beam emitted through a high numerical aperture objective lens. Coupling optical trapping with other technologies is possible and allows stable sample trapping, while also facilitating molecular, chemical and spectroscopic analysis. For this reason, we are exploring laser trapping combined with laser spectroscopy as a potential non-invasive method of interrogating individual cells with a high degree of specificity in terms of information generated. Thus, for the delivery of as much pathological information as possible, we use a home-build optical trapping and spectroscopy system for real time probing human immunodeficiency virus (HIV-1) infected and uninfected single cells. Briefly, our experimental rig comprises an infrared continuous wave laser at 1064 nm with power output of 1.5 W, a 100X high numerical aperture oil-immersion microscope objective used to capture and immobilise individual cell samples as well as an excitation source. Spectroscopy spectral patterns obtained by the 1064 nm laser beam excitation provide information on HIV-1 infected and uninfected cells. We present these preliminary findings which may be valuable for the development of an HIV-1 point of care detection system.

  9. All-optical optoacoustic microscopy based on probe beam deflection technique

    Directory of Open Access Journals (Sweden)

    Saher M. Maswadi

    2016-09-01

    Full Text Available Optoacoustic (OA microscopy using an all-optical system based on the probe beam deflection technique (PBDT for detection of laser-induced acoustic signals was investigated as an alternative to conventional piezoelectric transducers. PBDT provides a number of advantages for OA microscopy including (i efficient coupling of laser excitation energy to the samples being imaged through the probing laser beam, (ii undistorted coupling of acoustic waves to the detector without the need for separation of the optical and acoustic paths, (iii high sensitivity and (iv ultrawide bandwidth. Because of the unimpeded optical path in PBDT, diffraction-limited lateral resolution can be readily achieved. The sensitivity of the current PBDT sensor of 22 μV/Pa and its noise equivalent pressure (NEP of 11.4 Pa are comparable with these parameters of the optical micro-ring resonator and commercial piezoelectric ultrasonic transducers. Benefits of the present prototype OA microscope were demonstrated by successfully resolving micron-size details in histological sections of cardiac muscle.

  10. Formation and evolution of planetary systems: the impact of high angular resolution optical techniques

    CERN Document Server

    Absil, Olivier; 10.1007/s00159-009-0028-y

    2009-01-01

    The direct images of giant extrasolar planets recently obtained around several main sequence stars represent a major step in the study of planetary systems. These high-dynamic range images are among the most striking results obtained by the current generation of high angular resolution instruments, which will be superseded by a new generation of instruments in the coming years. It is therefore an appropriate time to review the contributions of high angular resolution visible/infrared techniques to the rapidly growing field of extrasolar planetary science. During the last 20 years, the advent of the Hubble Space Telescope, of adaptive optics on 4- to 10-m class ground-based telescopes, and of long-baseline infrared stellar interferometry has opened a new viewpoint on the formation and evolution of planetary systems. By spatially resolving the optically thick circumstellar discs of gas and dust where planets are forming, these instruments have considerably improved our models of early circumstellar environments...

  11. Mechanical, dielectric and optical assessment of glass composites prepared using milling technique

    Indian Academy of Sciences (India)

    Gurbinder Kaur; G Pickrell; V Kumar; O P Pandey; K Singh; S K Arya

    2015-08-01

    In the present investigation, mechanical and spectroscopic properties of glass composites have been investigated. The glass composites have been prepared by the milling technique instead of using any filler particle. Due to the presence of different alkaline earth modifiers in composites, marked difference in their strength and optical properties is observed. The band gap, Urbach energy and the extinction coefficient of the glass composites have been calculated using UV–visible spectroscopy. Moreover, the real and imaginary dielectric constants have also been calculated for all the composites in addition to the Weibull statistics and cumulative probability of failure. The results have been discussed in light of comparison between the glass composites and the individual glasses. The mechanical and optical properties indicate marked effect on the mechanical strength, band gap and Urbach energy for glass composites as compared with the individual glasses.

  12. Development of molecular based optical techniques for thermometry and velocimetry for fluorocarbon media

    Science.gov (United States)

    Pouya, Shahram; Blanchard, Gary; Koochesfahani, Manoochehr

    2016-11-01

    Fluorocarbon solvents are very stable inert fluids with unique physical properties that make them attractive compounds as refrigerant and several medical applications such as contrast enhanced ultrasound imaging. Since they do not mix with typical organic solvents or water, most luminescent (fluorescent or phosphorescent) probes cannot be used as tracers for optical diagnostic techniques. Perfluoropentane, a compound from this family, is used as a simulant fluid by NASA for two-phase heat transfer/mixing experiments under micro-gravity condition due to its low boiling temperature. Here we study the feasibility of employing non-intrusive optical methods for measurements of temperature and/or velocity within Perfluoropentane as the working fluid. Preliminary results of temperature and velocity measurement using Laser Induced Fluorescence and Molecular Tagging Velocimetry are presented. This work was supported by NASA Grant Number NNX16AD52A.

  13. Construction and Optical Testing of Inflatable Membrane Mirror Using Structured Light Technique

    Directory of Open Access Journals (Sweden)

    Felipe Patiño-Jiménez

    2015-01-01

    Full Text Available Construction and characterization of an inflatable mirror prototype made out of flexible polymeric membranes are being presented. Surfaces were curved by imposing a slight excess of air pressure. Lightweighted, lowcost, and commercially available materials were selected in order to produce solar concentration elements at competitive prices. In this sense, large-area, image-forming mirrors with low optical acuity were achieved by concentration purposes. Optical characterization of the mirror’s shape at a given pressure or curvature radius was done by means of a structuredlight technique with a resolution of 0.1 mm finding a conical shape acquired by the inflated mirror as the best approximation. Concentration ratio achieved for a focal length of 5068 mm was of 25.1 suns, making a promising approach for lowering initial investment costs in applications such as hot-water, parabolic dish with Stirling engines, or concentrated photovoltaic electricity generation.

  14. Synthesis of MgO Nanoparticles by Solvent Mixed Spray Pyrolysis Technique for Optical Investigation

    Directory of Open Access Journals (Sweden)

    K. R. Nemade

    2014-01-01

    Full Text Available Solvent mixed spray pyrolysis technique has attracted a global interest in the synthesis of nanomaterials since reactions can be run in liquid state without further heating. Magnesium oxide (MgO is a category of the practical semiconductor metal oxides, which is extensively used as catalyst and optical material. In the present study, MgO nanoparticles were successfully synthesized using a solvent mixed spray pyrolysis. The X-ray diffraction pattern confirmed the formation of MgO phase with an excellent crystalline structure. Debye-Scherrer equation is used for the determination of particle size, which was found to be 9.2 nm. Tunneling electron microscope analysis indicated that the as-synthesized particles are nanoparticles with an average particle size of 9 nm. Meanwhile, the ultraviolet-visible spectroscopy of the resulting product was evaluated to study its optical property via measurement of the band gap energy value.

  15. [Techniques of on-line monitoring volatile organic compounds in ambient air with optical spectroscopy].

    Science.gov (United States)

    Du, Zhen-Hui; Zhai, Ya-Qiong; Li, Jin-Yi; Hu, Bo

    2009-12-01

    Volatile organic compounds (VOCs) are harmful gaseous pollutants in the ambient air. The techniques of on-line monitoring VOCs are very significant for environment protection. Until now, there is no single technology that can meet all the needs of monitoring various VOCs. The characteristics and present situation of several optical methods, which can be applied to on-line monitoring VOCs, including non dispersive infrared (NDIR), Fourier transform infrared (FTIR) spectroscopy, differential optical absorption spectroscopy (DOAS), and laser spectroscopy were reviewed. Comparison was completed between the national standard methods and spectroscopic method for measuring VOCs. The main analysis was focused on the status and trends of tuning diode laser absorption spectroscopy (TDLAS) technology.

  16. High-resolution fiber optic temperature sensors using nonlinear spectral curve fitting technique

    Science.gov (United States)

    Su, Z. H.; Gan, J.; Yu, Q. K.; Zhang, Q. H.; Liu, Z. H.; Bao, J. M.

    2013-04-01

    A generic new data processing method is developed to accurately calculate the absolute optical path difference of a low-finesse Fabry-Perot cavity from its broadband interference fringes. The method combines Fast Fourier Transformation with nonlinear curve fitting of the entire spectrum. Modular functions of LabVIEW are employed for fast implementation of the data processing algorithm. The advantages of this technique are demonstrated through high performance fiber optic temperature sensors consisting of an infrared superluminescent diode and an infrared spectrometer. A high resolution of 0.01 °C is achieved over a large dynamic range from room temperature to 800 °C, limited only by the silica fiber used for the sensor.

  17. An optical fiber MEMS pressure sensor using microwave photonics filtering technique

    Science.gov (United States)

    Wang, Yiping; Wang, Ming; Ni, Xiaoqi; Xia, Wei; Guo, Dongmei; Hao, Hui; Ma, Qingyu; Zhuang, Wei

    2017-04-01

    A fiber-optic micro-electromechanical systems (MEMS) extrinsic Fabry-Perot interferometer (EFPI) pressure sensor exploiting microwave photonics filtering technique is firstly proposed and experimentally demonstrated. A single-bandpass microwave photonic filter (MPF) which mainly consists of a spectrum-sliced light source, a pressurized EFPI, a phase modulator (PM) and a length of dispersion compensating fiber (DCF) is demonstrated. The frequency response of the filter with respect to the pressure is studied. By detecting the resonance frequency shifts of the MPF, the pressure can be determined. The theoretical and experimental results show that the proposed EFPI pressure sensor has a higher resolution and higher speed than traditional methods based on optical spectrum analysis. The sensitivity of the sensor is measured to be as high as 86 MHz/MPa in the range of 0-4MPa.

  18. Structural and optical properties of CdO thin films deposited by RF magnetron sputtering technique

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, G. Anil, E-mail: anilhcu@gmail.com; Reddy, M. V. Ramana, E-mail: anilhcu@gmail.com [Department of Physics, Osmania University, Hyderabad-500007 (India); Reddy, Katta Narasimha, E-mail: anilhcu@gmail.com [Department of Physics, Mahatma Gandhi University, Nalgonda-508003 (India)

    2014-04-24

    Cadmium oxide (CdO) thin films were deposited on glass substrate by r.f. magnetron sputtering technique using a high purity (99.99%) Cd target of 2-inch diameter and 3 mm thickness in an Argon and oxygen mixed atmosphere with sputtering power of 50W and sputtering pressure of 2×10{sup −2} mbar. The prepared films were characterized by X-ray diffraction (XRD), optical spectroscopy and scanning electron microscopy (SEM). The XRD analysis reveals that the films were polycrystalline with cubic structure. The visible range transmittance was found to be over 70%. The optical band gap increased from 2.7 eV to2.84 eV with decrease of film thickness.

  19. Optical asymmetric cryptography based on elliptical polarized light linear truncation and a numerical reconstruction technique.

    Science.gov (United States)

    Lin, Chao; Shen, Xueju; Wang, Zhisong; Zhao, Cheng

    2014-06-20

    We demonstrate a novel optical asymmetric cryptosystem based on the principle of elliptical polarized light linear truncation and a numerical reconstruction technique. The device of an array of linear polarizers is introduced to achieve linear truncation on the spatially resolved elliptical polarization distribution during image encryption. This encoding process can be characterized as confusion-based optical cryptography that involves no Fourier lens and diffusion operation. Based on the Jones matrix formalism, the intensity transmittance for this truncation is deduced to perform elliptical polarized light reconstruction based on two intensity measurements. Use of a quick response code makes the proposed cryptosystem practical, with versatile key sensitivity and fault tolerance. Both simulation and preliminary experimental results that support theoretical analysis are presented. An analysis of the resistance of the proposed method on a known public key attack is also provided.

  20. Sensor-Based Technique for Manually Scanned Hand-Held Optical Coherence Tomography Imaging

    Directory of Open Access Journals (Sweden)

    Paritosh Pande

    2016-01-01

    Full Text Available Hand-held optical coherence tomography (OCT imaging probes offer flexibility to image sites that are otherwise challenging to access. While the majority of hand-held imaging probes utilize galvanometer- or MEMS-scanning mirrors to transversely scan the imaging beam, these probes are commonly limited to lateral fields-of-view (FOV of only a few millimeters. The use of a freehand manually scanned probe can significantly increase the lateral FOV. However, using the traditional fixed-rate triggering scheme for data acquisition in a manually scanned probe results in imaging artifacts due to variations in the scan velocity of the imaging probe. These artifacts result in a structurally inaccurate image of the sample. In this paper, we present a sensor-based manual scanning technique for OCT imaging, where real-time feedback from an optical motion sensor is used to trigger data acquisition. This technique is able to circumvent the problem of motion artifacts during manual scanning by adaptively altering the trigger rate based on the instantaneous scan velocity, enabling OCT imaging over a large lateral FOV. The feasibility of the proposed technique is demonstrated by imaging several biological and nonbiological samples.

  1. Efficient optical design and measurement technique to six sigma laser processing

    Science.gov (United States)

    Scaggs, Michael; Haas, Gil

    2014-03-01

    A six sigma laser processing system is proposed that utilizes real time measurement of ISO 11146 and ISO 13694 laser beam parameters without disrupting the process beam and with minimal loss. If key laser beam parameters can be measured during a laser process, without a disruption to the process, then a higher level of process control can be realized. The difficulty in achieving this concept to date is that most accepted beam measurement techniques are time averaged and require interruption of the laser beam and therefore have made it impractical for real time measurement which is necessary to consider six sigma process control. Utilizing an all passive optical technique to measure a laser's beam waist and other parameters for both focused and unfocused beams, the direct measurement of the ISO laser beam parameters are realized without disruption to the process and with minimal loss. The technique is simple enough to be applied to low and high power systems well into the multi-kilowatt range. Through careful monitoring of all laser beam parameters via software control of upper and lower limits for these parameters, tighter quality control is possible for achieving a six sigma process. In this paper we describe the optical design for both low and high power laser systems and how six sigma laser processing may be realized.

  2. Detection of Biomass in New York City Aerosols: Light Scattering and Optical Fluorescence Techniques

    Science.gov (United States)

    Niebauer, M.; Alimova, A.; Katz, A.; Xu, M.; Rudolph, E.; Steiner, J.; Alfano, R. R.

    2005-12-01

    Optical spectroscopy is an ideal method for detecting bacteria and spores in real time. Optical fluorescence spectroscopy examination of New York City aerosols is used to quantify the mass of bacteria spores present in air masses collected at 14 liters/minute onto silica fiber filters, and on silica fiber ribbons using an Environmental Beta Attenuation Monitor manufactured by MetOne Instruments configured for the PM2.5 fraction. Dipicolinic acid (DPA), a molecule found primarily in bacterial spores, is the most characteristic component of spores in trial experiments on over 200 collected aerosol samples. DPA is extracted from the spores using a heat bath and chelated with Terbium. The DPA:Tb is detected by measuring its characteristic fluorescence with emission bands at 490, 545 and 585 nm for 270 nm excitation. Light scattering also measures the size distribution for a number of a variety of bacteria - Bacillus subtilis (rod shaped), Staphylococcus aureus (spherical) and Pseudomonas aeruginosa (short rods) establishing that optical techniques satisfactorily distinguish populations based on their variable morphology. Size and morphology are obtained by applying a variation of the Gaussian Ray Approximation theory of anomalous diffraction theory to an analysis of the transmission spectra in the range of 0.4 to 1.0 microns. In test experiments, the refractive index of the inner spore core of Bacillus subtilis decreases from 1.51 to 1.39 while the spore radius enlarges from 0.38 to 0.6 micrometers. Optical determinations are verified by oil-immersion techniques and by scanning electron microscope measurements. Characterization of spores, germinating spore materials, and bacteria is considered vital to tracing bacteria in the environment, for the development of life-detection systems for planetary exploration, monitoring pathogens in environmental systems, and for the preparation of anti-terrorism strategies.

  3. Scheme for independently stabilizing the repetition rate and optical frequency of a laser using a regenerative mode-locking technique.

    Science.gov (United States)

    Nakazawa, Masataka; Yoshida, Masato

    2008-05-15

    We have succeeded in achieving independent control of the repetition rate and optical frequency of a pulse laser by employing a regenerative mode-locking technique. By adopting a voltage-controlled microwave phase shifter or an optical delay line in a regenerative feedback loop we can control the repetition rate of the laser without directly disturbing the optical frequencies. We experimentally show how this independent control can be realized by employing a 40 GHz harmonically and regeneratively mode-locked fiber laser.

  4. Assessment of Spacecraft Operational Status Using Electro-Optical Predictive Techniques

    Science.gov (United States)

    Swann, D.; Klem, B.; McCoy, B.

    2010-09-01

    The current class of small satellite systems presents an analyst responsible for monitoring spacecraft operational status and early detection of detrimental anomalies with a broad variety of sensing and identification issues and challenges. Simple, small, cube-shaped satellites, without protruding solar panel appendages, may require enhanced preflight characterization processes to support monitoring by passive, remote, nonimaging optical sensors. This paper will describe spacecraft optical signature modeling and simulation techniques to develop sensing and identification algorithms for observing and characterizing key spacecraft features. The simulation results are based on electro-optical signatures apparent to nonimaging sensors, along with related observable features derived from multicolor and multiviewing aspect scenarios. This model and simulation analysis capability is used to support programs to monitor spacecraft performance status and identify anomalies associated with spacecraft damage/deterioration due to space debris or micrometeorite impact, thruster exhaust deposition or material aging. The development of state-of-the-art optical signature modeling tools to perform high-fidelity satellite models (such as the Air Force Academy FalconSat-5 or AFRL TacSat-3) simulations to characterize spectral radiant intensities apparent to passive, remote, nonresolved imaging sensors are described in detail. Simulations are performed for a comprehensive scenario range of natural (solar and earth) illumination and viewing conditions. Results are generated for comparing baseline, streamlined geometry models with the actual higher fidelity models that capture vehicle small-size hardware components and modifications. Output consisting of radiant intensity history apparent to ground-based sensor locations for vehicle trajectories that capture a comprehensive range of illumination conditions from the sun and underlying earth scene are presented for extensive spectral band

  5. Sub-wavelength terahertz beam profiling of a THz source via an all-optical knife-edge technique

    CERN Document Server

    Ho, Sze Phing; Shalaby, Mostafa; Peccianti, Marco; Clerici, Matteo; Pasquazi, Alessia; Ozturk, Yavuz; Ali, Jalil; Morandotti, Roberto

    2015-01-01

    We propose an all-optical Knife Edge characterization technique and we demonstrate its working principle by characterizing the sub-{\\lambda} features of a spatially modulated Terahertz source directly on the nonlinear crystal employed for the Terahertz generation.

  6. Nonlinear optical techniques for imaging and manipulating the mouse central nervous system

    Science.gov (United States)

    Farrar, Matthew John

    The spinal cord of vertebrates serves as the conduit for somatosensory information and motor control, as well as being the locus of neural circuits that govern fast reflexes and patterned behaviors, such as walking in mammals or swimming in fish. Consequently, pathologies of the spinal cord -such as spinal cord injury (SCI)- lead to loss of motor control and sensory perception, with accompanying decline in life expectancy and quality of life. Despite the devastating effects of these diseases, few therapies exist to substantially ameliorate patient outcome. In part, studies of spinal cord pathology have been limited by the inability to perform in vivo imaging at the level of cellular processes. The focus of this thesis is to present the underlying theory for and demonstration of novel multi-photon microscopy (MPM) and optical manipulation techniques as they apply to studies the mouse central nervous system (CNS), with an emphasis on the spinal cord. The scientific findings which have resulted from the implementation of these techniques are also presented. In particular, we have demonstrated that third harmonic generation is a dye-free method of imaging CNS myelin, a fundamental constituent of the spinal cord that is difficult to label using exogenous dyes and/or transgenic constructs. Since gaining optical access to the spinal cord is a prerequisite for spinal cord imaging, we review our development of a novel spinal cord imaging chamber and surgical procedure which allowed us to image for multiple weeks following implantation without the need for repeated surgeries. We also have used MPM to characterize spinal venous blood flow before and after point occlusions. We review a novel nonlinear microscopy technique that may serve to show optical interfaces in three dimensions inside scattering tissue. Finally, we discuss a model and show results of optoporation, a means of transfecting cells with genetic constructs. Brief reviews of MPM and SCI are also presented.

  7. Progress in the development of deposition prevention and cleaning techniques of in-vessel optics in ITER

    Science.gov (United States)

    Mukhin, E.; Vukolov, K.; Semenov, V.; Tolstyakov, S.; Kochergin, M.; Kurskiev, G.; Podushnikova, K.; Razdobarin, A.; Gorodetsky, A.; Zalavutdinov, R.; Bukhovets, V.; Zakharov, A.; Bulovich, S.; Veiko, V.; Shakshno, E.

    2009-08-01

    The lifetime of front optical components unprotected from reactor grade plasmas may be very short due to intensive contamination with carbon and beryllium-based materials eroded by the plasma from beryllium walls and carbon tiles. Deposits result in a significant reduction and spectral alterations of optical transmission. In addition, even rather thin and transparent deposits can dramatically change the shape of reflectance spectra, especially for mirrors with rather low reflectivity, such as W or Mo. The distortion of data obtained with various optical diagnostics may affect the safe operation of ITER. Therefore, the development of optics-cleaning and deposition-mitigating techniques is a key factor in the construction and operation of optical diagnostics in ITER. The problem is of particular concern for optical elements positioned in the divertor region. The latest achievements in protection of in-vessel optics are presented using the example of deposition prevention/cleaning techniques for in-machine components of the Thomson scattering system in the divertor. Careful consideration of well-known and novel protection approaches shows that neither of them alone provides guaranteed survivability of the first in-vessel optics in the divertor. Only a set of complementary prevention/cleaning techniques, which include special materials for mirrors and inhibition additives for plasma, is able to manage the challenging task. The essential issue, which needs to be addressed in the immediate future, is an extensive development of techniques tested under experimental conditions (exposure time and contamination fluxes) similar to those expected in ITER.

  8. Fast all-optical nuclear spin echo technique based on EIT

    Science.gov (United States)

    Walther, Andreas; Nilsson, Adam N.; Li, Qian; Rippe, Lars; Kröll, Stefan

    2016-08-01

    We demonstrate an all-optical Raman spin echo technique, using electromagnetically induced transparency (EIT) to create the pulses required for a spin echo sequence: initialization, pi-rotation, and readout. The first pulse of the sequence induces coherence directly from a mixed state, and the technique is used to measure the nuclear spin coherence of an inhomogeneously broadened ensemble of rare-earth ions (Pr3 +) in a crystal. The rephasing pi-rotation is shown to offer an advantage of combining the rephasing action with the operation of a phase gate, particularly useful in e.g. dynamic decoupling sequences. In contrast to many previous experiments the sequence does not require any preparatory hole burning, which greatly shortens the total duration of the sequence. The effect of the different pulses is characterized by quantum state tomography and compared with simulations. We demonstrate two applications of the technique: compensating the magnetic field across our sample by monitoring T 2 reductions from stray magnetic fields, and measuring coherence times at temperatures up to 11 K, where standard preparation techniques are difficult to implement. We explore the potential of the technique, in particular for systems with much shorter T 2, and other possible applications.

  9. Nanomaterials-Based Optical Techniques for the Detection of Acetylcholinesterase and Pesticides

    Directory of Open Access Journals (Sweden)

    Ning Xia

    2014-12-01

    Full Text Available The large amount of pesticide residues in the environment is a threat to global health by inhibition of acetylcholinesterase (AChE. Biosensors for inhibition of AChE have been thus developed for the detection of pesticides. In line with the rapid development of nanotechnology, nanomaterials have attracted great attention and have been intensively studied in biological analysis due to their unique chemical, physical and size properties. The aim of this review is to provide insight into nanomaterial-based optical techniques for the determination of AChE and pesticides, including colorimetric and fluorescent assays and surface plasmon resonance.

  10. A Simple Technique to Facilitate Treatment of Urethral Strictures with Optical Internal Urethrotomy

    Directory of Open Access Journals (Sweden)

    Konstantinos Stamatiou

    2014-01-01

    Full Text Available Urethral stricture is a common condition that can lead to serious complications such as urinary infections and renal insufficiency secondary to urinary retention. Treatment options include catheterization, urethroplasty, endoscopic internal urethrotomy, and dilation. Optical internal urethrotomy offers faster recovery, minimal scarring, and less risk of infection, although recurrence is possible. However, technical difficulties associated with poor visualization of the stenosis or of the urethral lumen may increase procedural time and substantially increase the failure rates of internal urethrotomy. In this report we describe a technique for urethral catheterization via a suprapubic, percutaneous approach through the urinary bladder in order to facilitate endoscopic internal urethrotomy.

  11. Effects of absorbing media on relative optical interference intensity ROII technique

    Institute of Scientific and Technical Information of China (English)

    P.L.Wong; F.Guo

    2001-01-01

    The optical interference intensity ROll technique, which enables measurements of filmthickness of magnitude below half of the wavelength of the incident light, is widely used in thestudy of thin film lubrication (TFL). However, the absorbing characteristics of the metallic compo-nents which are for generating suitable amount of reflectance to facilitate optimum inference im-ages has never been taken into consideration. This paper presents a theoretical analysis of theabsorbing characteristics. Results indicate that without acknowledging the absorbing effects, sig-nificant errors in film thickness measurements can be induced.

  12. Alternative technique for biodiesel quality control using an optical fiber long-period grating sensor

    Energy Technology Data Exchange (ETDEWEB)

    Falate, Rosane [Universidade Estadual de Ponta Grossa, PR (Brazil). Dept. de Informatica; Nike, Karen; Costa Neto, Pedro Ramos da [Universidade Tecnologica Federal do Parana, Curitiba (Brazil). Dept. de Quimica; Cacao Junior, Eduardo; Muller, Marcia; Kalinowski, Hypolito Jose; Fabris, Jose Luis [Universidade Tecnologica Federal do Parana, Curitiba (Brazil). Dept. de Fisica]. E-mail: fabris@utfpr.edu.br

    2007-07-01

    We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method. (author)

  13. Alternative technique for biodiesel quality control using an optical fiber long-period grating sensor

    Directory of Open Access Journals (Sweden)

    Rosane Falate

    2007-01-01

    Full Text Available We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method.

  14. Classification of remotely sensed data using OCR-inspired neural network techniques. [Optical Character Recognition

    Science.gov (United States)

    Kiang, Richard K.

    1992-01-01

    Neural networks have been applied to classifications of remotely sensed data with some success. To improve the performance of this approach, an examination was made of how neural networks are applied to the optical character recognition (OCR) of handwritten digits and letters. A three-layer, feedforward network, along with techniques adopted from OCR, was used to classify Landsat-4 Thematic Mapper data. Good results were obtained. To overcome the difficulties that are characteristic of remote sensing applications and to attain significant improvements in classification accuracy, a special network architecture may be required.

  15. Development of a Direct Fabrication Technique for Full-Shell X-Ray Optics

    Science.gov (United States)

    Gubarev, M.; Kolodziejczak, J. K.; Griffith, C.; Roche, J.; Smith, W. S.; Kester, T.; Atkins, C.; Arnold, W.; Ramsey, B.

    2016-01-01

    Future astrophysical missions will require fabrication technology capable of producing high angular resolution x-ray optics. A full-shell direct fabrication approach using modern robotic polishing machines has the potential for producing high resolution, light-weight and affordable x-ray mirrors that can be nested to produce large collecting area. This approach to mirror fabrication, based on the use of the metal substrates coated with nickel phosphorous alloy, is being pursued at MSFC. The design of the polishing fixtures for the direct fabrication, the surface figure metrology techniques used and the results of the polishing experiments are presented.

  16. Measurement of Temperature Change in Nonlinear Optical Materials by Using the Z-Scan Technique

    Institute of Scientific and Technical Information of China (English)

    DONG Shu-Guang; YANG Jun-Yi; SHUI Min; YI Chuan-Xiang; LI Zhong-Guo; SONG Ying-Lin

    2011-01-01

    @@ Spatial and temporal changes of temperature in a novel polymer are investigated by using the Z-scan technique under ns laser pulse excitation.According to the open aperture Z-scan experimental results, the nonlinear absorption coefficient of the polymer is determined.By solving the diffusion equation of heat conduction induced by optical absorption, the spatial and temporal changes in temperature are obtained.This change in temperature drives the photo-acoustic and electromagnetic wave propagating in the polymer and induces the change in refractive index, which serves as a negative lens, and the closed aperture Z-scan shows a peak and valley profile.Based on the numerical calculation, we achieve a good fit to the closed-aperture Z-scan curve with an optimized nonlinear refractive index.This consistency attests the existence of temperature change in the solution, and the Z-scan technique is suitable to investigate this change in temperature.

  17. Development of fiber-optic current sensing technique and its applications in electric power systems

    Science.gov (United States)

    Kurosawa, Kiyoshi

    2014-03-01

    This paper describes the development and applications of a fiber-optic electric current sensing technique with the stable properties and compact, simple, and flexible structure of the sensing device. The special characteristics of the sensors were achieved by use of the special low birefringence fiber as the Faraday-effect sensing element and were also achieved with creation of sensing schemes which matched with the features of the fiber. Making use of the excellent features of the sensing technique, various current monitoring devices and systems were developed and applied practically for the control and maintenance in the electric power facility. In this paper, the design and performance of the sensing devices are introduced first. After that, examples of the application systems practically applied are also introduced, including fault section/point location systems for power transmission cable lines.

  18. Technique of fiber optics used to localize epidural space in piglets.

    Science.gov (United States)

    Ting, Chien-Kun; Chang, Yin

    2010-05-24

    Technique of loss-of-resistance in epidural block is commonly used for epidural anesthesia in humans with approximately 90% successful rate. However, it may be one of the most difficult procedures to learn for anesthesia residents in hospital. A two-wavelength (650 nm and 532 nm) fiber-optical method has been developed according to the characteristic reflectance spectra of ex-vivo porcine tissues, which are associated with the needle insertion to localize the epidural space (ES). In an in-vivo study in piglets showed that the reflected lights from ES and its surrounding tissue ligamentum flavum (LF) are highly distinguishable. This indicates that this technique has potential to localize the ES on the spot without the help of additional guiding assistance.

  19. A new burst assembly technique for supporting QoS in optical burst switching networks

    Institute of Scientific and Technical Information of China (English)

    Xiaolong Yang(阳小龙); Mingrui Dang(党明瑞); Youju Mao(毛幼菊); Lemin Li(李乐民)

    2003-01-01

    This letter proposes a new burst assembly technique for supporting QoS in optical burst switching (OBS)networks. It consists of the adaptive-threshold burst assembly mechanism and QoS-based random offset-time scheme. The assembly mechanism, which is fit well to multi-class burst assembly, not only matcheswith IP QoS mechanism based on packet classification, and also utilizes fairly and efficiently assemblycapacity. Based on token-bucket model and burst segment selective discard (BSSD), the offset-time schemecan smooth the traffic to support OBS QoS. The simulation results show that the technique can improvethe performance in terms of packet loss probability (PLP).

  20. An accurate automated technique for quasi-optics measurement of the microwave diagnostics for fusion plasma

    Science.gov (United States)

    Hu, Jianqiang; Liu, Ahdi; Zhou, Chu; Zhang, Xiaohui; Wang, Mingyuan; Zhang, Jin; Feng, Xi; Li, Hong; Xie, Jinlin; Liu, Wandong; Yu, Changxuan

    2017-08-01

    A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.

  1. Test of the notch technique for determining the radial sensitivity of the optical model potential

    CERN Document Server

    Yang, Lei; Jia, Hui-ming; Xu, Xin-Xing; Ma, Nan-Ru; Sun, Li-Jie; Yang, Feng; Zhang, Huan-Qiao; Li, Zu-Hua; Wang, Dong-Xi

    2015-01-01

    Detailed investigations on the notch technique are performed on the ideal data generated by the optical model potential parameters extracted from the 16O+208Pb system at the laboratory energy of 129.5 MeV, to study the sensitivities of this technique on the model parameters as well as the experimental data. It is found that, for the perturbation parameters, a sufficient large reduced fraction and an appropriate small perturbation width are necessary to determine the accurate radial sensitivity; while for the potential parameters, almost no dependence was observed. For the experimental measurements, the number of data points has little influence for the heavy target system, and the relative inner information of the nuclear potential can be derived when the measurement extended to a lower cross section.

  2. Investigation of optical properties of multilayer dielectric structures using prism-coupling technique

    Energy Technology Data Exchange (ETDEWEB)

    Sokolov, V I; Glebov, V N; Malyutin, A M; Molchanova, S I; Khaydukov, E V; Panchenko, V Ya [Institute on Laser and Information Technologies, Russian Academy of Sciences, Shatura, Moscow Region (Russian Federation)

    2015-09-30

    A method based on resonant excitation of waveguide modes with a prism coupler is proposed for measuring the thickness and refractive index of thin-film layers in multilayer dielectric structures. The peculiarities of reflection of TE- and TM-polarised light beams from a structure comprising eleven alternating layers of zinc sulfide (ZnS) and magnesium barium fluoride (MgBaF{sub 4}), whose thicknesses are much less than the wavelength of light, are investigated. Using the mathematical model developed, we have calculated the coefficients of reflection of collimated TE and TM light beams from a multilayer structure and determined the optical constants and thicknesses of the structure layers. The refractive indices of the layers, obtained for TE and TM polarisation of incident light, are in good agreement. The thicknesses of ZnS and MgBaF{sub 4} layers, found for different polarisations, coincide with an accuracy of ±1%. Thus, we have demonstrated for the first time that the prism-coupling technique allows one to determine the optical properties of thin-film structures when the number of layers in the structure exceeds ten layers. (integrated optics)

  3. Dual beam light profile microscopy: a new technique for optical absorption depth profilometry.

    Science.gov (United States)

    Power, J F; Fu, S W

    2004-02-01

    Light profile microscopy (LPM) is a recently developed technique of optical inspection that is used to record micrometer-scale images of thin-film cross-sections on a direct basis. In single beam mode, LPM provides image contrast based on luminescence, elastic, and/or inelastic scatter. However, LPM may also be used to depth profile the optical absorption coefficient of a thin film based on a method of dual beam irradiation presented in this work. The method uses a pair of collimated laser beams to consecutively irradiate a film from two opposing directions along the depth axis. An average profile of the beam's light intensity variation through the material is recovered for each direction and used to compute a depth-dependent differential absorbance profile. This latter quantity is shown from theory to be related to the film's depth-dependent optical absorption coefficient through a simple linear model that may be inverted by standard methods of numerical linear algebra. The inverse problem is relatively well posed, showing good immunity to data errors. This profilometry method is experimentally applied to a set of well-characterized materials with known absorption properties over a scale of tens of micrometers, and the reconstructed absorption profiles were found to be highly consistent with the reference data.

  4. Diffractive optics development using a modified stack-and-draw technique.

    Science.gov (United States)

    Pniewski, Jacek; Kasztelanic, Rafal; Nowosielski, Jedrzej M; Filipkowski, Adam; Piechal, Bernard; Waddie, Andrew J; Pysz, Dariusz; Kujawa, Ireneusz; Stepien, Ryszard; Taghizadeh, Mohammad R; Buczynski, Ryszard

    2016-06-20

    We present a novel method for the development of diffractive optical elements (DOEs). Unlike standard surface relief DOEs, the phase shift is introduced through a refractive index variation achieved by using different types of glass. For the fabrication of DOEs we use a modified stack-and-draw technique, originally developed for the fabrication of photonic crystal fibers, resulting in a completely flat element that is easy to integrate with other optical components. A proof-of-concept demonstration of the method is presented-a two-dimensional binary optical phase grating in the form of a square chessboard with a pixel size of 5 μm. Two types of glass are used: low refractive index silicate glass NC21 and high refractive index lead-silicate glass F2. The measured diffraction characteristics of the fabricated component are presented and it is shown numerically and experimentally that such a DOE can be used as a fiber interconnector that couples light from a small-core fiber into the several cores of a multicore fiber.

  5. Multivariate reference technique for quantitative analysis of fiber-optic tissue Raman spectroscopy.

    Science.gov (United States)

    Bergholt, Mads Sylvest; Duraipandian, Shiyamala; Zheng, Wei; Huang, Zhiwei

    2013-12-03

    We report a novel method making use of multivariate reference signals of fused silica and sapphire Raman signals generated from a ball-lens fiber-optic Raman probe for quantitative analysis of in vivo tissue Raman measurements in real time. Partial least-squares (PLS) regression modeling is applied to extract the characteristic internal reference Raman signals (e.g., shoulder of the prominent fused silica boson peak (~130 cm(-1)); distinct sapphire ball-lens peaks (380, 417, 646, and 751 cm(-1))) from the ball-lens fiber-optic Raman probe for quantitative analysis of fiber-optic Raman spectroscopy. To evaluate the analytical value of this novel multivariate reference technique, a rapid Raman spectroscopy system coupled with a ball-lens fiber-optic Raman probe is used for in vivo oral tissue Raman measurements (n = 25 subjects) under 785 nm laser excitation powers ranging from 5 to 65 mW. An accurate linear relationship (R(2) = 0.981) with a root-mean-square error of cross validation (RMSECV) of 2.5 mW can be obtained for predicting the laser excitation power changes based on a leave-one-subject-out cross-validation, which is superior to the normal univariate reference method (RMSE = 6.2 mW). A root-mean-square error of prediction (RMSEP) of 2.4 mW (R(2) = 0.985) can also be achieved for laser power prediction in real time when we applied the multivariate method independently on the five new subjects (n = 166 spectra). We further apply the multivariate reference technique for quantitative analysis of gelatin tissue phantoms that gives rise to an RMSEP of ~2.0% (R(2) = 0.998) independent of laser excitation power variations. This work demonstrates that multivariate reference technique can be advantageously used to monitor and correct the variations of laser excitation power and fiber coupling efficiency in situ for standardizing the tissue Raman intensity to realize quantitative analysis of tissue Raman measurements in vivo, which is particularly appealing in

  6. Satellite Angular Velocity Estimation Based on Star Images and Optical Flow Techniques

    Directory of Open Access Journals (Sweden)

    Giancarmine Fasano

    2013-09-01

    Full Text Available An optical flow-based technique is proposed to estimate spacecraft angular velocity based on sequences of star-field images. It does not require star identification and can be thus used to also deliver angular rate information when attitude determination is not possible, as during platform de tumbling or slewing. Region-based optical flow calculation is carried out on successive star images preprocessed to remove background. Sensor calibration parameters, Poisson equation, and a least-squares method are then used to estimate the angular velocity vector components in the sensor rotating frame. A theoretical error budget is developed to estimate the expected angular rate accuracy as a function of camera parameters and star distribution in the field of view. The effectiveness of the proposed technique is tested by using star field scenes generated by a hardware-in-the-loop testing facility and acquired by a commercial-off-the shelf camera sensor. Simulated cases comprise rotations at different rates. Experimental results are presented which are consistent with theoretical estimates. In particular, very accurate angular velocity estimates are generated at lower slew rates, while in all cases the achievable accuracy in the estimation of the angular velocity component along boresight is about one order of magnitude worse than the other two components.

  7. Photoelasticity and DIC as optical techniques for monitoring masonry specimens under mechanical loads

    Science.gov (United States)

    Colla, C.; Gabrielli, E.

    2017-01-01

    To evaluate the complex behaviour of masonry structures under mechanical loads, numerical models are developed and continuously implemented at diverse scales, whilst, from an experimental viewpoint, laboratory standard mechanical tests are usually carried out by instrumenting the specimens via traditional measuring devices. Extracted values collected in the few points where the tools were installed are assumed to represent the behaviour of the whole specimen but this may be quite optimistic or approximate. Optical monitoring techniques may help in overcoming some of these limitations by providing full-field visualization of mechanical parameters. Photoelasticity and the more recent DIC, employed to monitor masonry columns during compression tests are here presented and a lab case study is compared listing procedures, data acquisitions, advantages and limitations. It is shown that the information recorded by traditional measuring tools must be considered limited to the specific instrumented points. Instead, DIC in particular among the optical techniques, is proving both a very precise global and local picture of the masonry performance, opening new horizons towards a deeper knowledge of this complex construction material. The applicability of an innovative DIC procedure to cultural heritage constructions is also discussed.

  8. 10-channel fiber array fabrication technique for parallel optical coherence tomography system

    Science.gov (United States)

    Arauz, Lina J.; Luo, Yuan; Castillo, Jose E.; Kostuk, Raymond K.; Barton, Jennifer

    2007-02-01

    Optical Coherence Tomography (OCT) shows great promise for low intrusive biomedical imaging applications. A parallel OCT system is a novel technique that replaces mechanical transverse scanning with electronic scanning. This will reduce the time required to acquire image data. In this system an array of small diameter fibers is required to obtain an image in the transverse direction. Each fiber in the array is configured in an interferometer and is used to image one pixel in the transverse direction. In this paper we describe a technique to package 15μm diameter fibers on a siliconsilica substrate to be used in a 2mm endoscopic probe tip. Single mode fibers are etched to reduce the cladding diameter from 125μm to 15μm. Etched fibers are placed into a 4mm by 150μm trench in a silicon-silica substrate and secured with UV glue. Active alignment was used to simplify the lay out of the fibers and minimize unwanted horizontal displacement of the fibers. A 10-channel fiber array was built, tested and later incorporated into a parallel optical coherence system. This paper describes the packaging, testing, and operation of the array in a parallel OCT system.

  9. Flat-top pulse generation by the optical Fourier transform technique for ultrahigh speed signal processing

    DEFF Research Database (Denmark)

    Palushani, Evarist; Oxenløwe, Leif Katsuo; Galili, Michael;

    2009-01-01

    This paper reports on the generation of 1.6-ps fullwidth at half-maximum flat-top pulses by the optical Fourier transform technique, and the utilization of these pulses in a 320-Gb/s demultiplexing experiment. It is demonstrated how a narrow pulse having a 15-nm wide third-order super-Gaussian sp......This paper reports on the generation of 1.6-ps fullwidth at half-maximum flat-top pulses by the optical Fourier transform technique, and the utilization of these pulses in a 320-Gb/s demultiplexing experiment. It is demonstrated how a narrow pulse having a 15-nm wide third-order super......-Gaussian spectral intensity profile is mapped into a flat-top pulse resembling its spectrum by simple propagation in SMF. Theoretical and experimental descriptions are given on flat-top pulse generation, and an experimental validation of the systems performance of the pulses is carried out, demonstrating a benefit...

  10. Advances in estimation methods of vegetation water content based on optical remote sensing techniques

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Quantitative estimation of vegetation water content(VWC) using optical remote sensing techniques is helpful in forest fire as-sessment,agricultural drought monitoring and crop yield estimation.This paper reviews the research advances of VWC retrieval using spectral reflectance,spectral water index and radiative transfer model(RTM) methods.It also evaluates the reli-ability of VWC estimation using spectral water index from the observation data and the RTM.Focusing on two main definitions of VWC-the fuel moisture content(FMC) and the equivalent water thickness(EWT),the retrieval accuracies of FMC and EWT using vegetation water indices are analyzed.Moreover,the measured information and the dataset are used to estimate VWC,the results show there are significant correlations among three kinds of vegetation water indices(i.e.,WSI,NDⅡ,NDWI1640,WI/NDVI) and canopy FMC of winter wheat(n=45).Finally,the future development directions of VWC detection based on optical remote sensing techniques are also summarized.

  11. Optical techniques for determination of the state of cure of epoxy resin based systems

    Science.gov (United States)

    Michie, W. C.; Thursby, G.; Johnstone, W.; Culshaw, B.

    1993-03-01

    Determination of the state of cure of epoxy resin based systems is of considerable interest to manufacturers of large carbon fiber reinforced plastic and glass reinforced plastic structures. Optical methods designed to indicate the cure state have been developed using a loss mechanism which is a function of the refractive index of the curing system. Such techniques are however subject to corruption from losses arising from other influences and consequently are limited in their measurement resolution. In this paper, two techniques which are able to provide a high degree of accuracy of measurement of refractive index are investigated as a means of performing cure measurements. The methods investigated involve the interaction of the evanescent field of a side polished optical fiber with an overlay waveguide or a surface plasmon. Coupling between the fiber and the overlay waveguide (or plasmon) is strongly influenced by the refractive index of the bulk superstrate above the overlay (in this case the curing resin system). Both sensing schemes are self referencing and are not influenced by loss.

  12. High-Speed Photography and Digital Optical Measurement Techniques for Geomaterials: Fundamentals and Applications

    Science.gov (United States)

    Xing, H. Z.; Zhang, Q. B.; Braithwaite, C. H.; Pan, B.; Zhao, J.

    2017-06-01

    Geomaterials (i.e. rock, sand, soil and concrete) are increasingly being encountered and used in extreme environments, in terms of the pressure magnitude and the loading rate. Advancing the understanding of the mechanical response of materials to impact loading relies heavily on having suitable high-speed diagnostics. One such diagnostic is high-speed photography, which combined with a variety of digital optical measurement techniques can provide detailed insights into phenomena including fracture, impact, fragmentation and penetration in geological materials. This review begins with a brief history of high-speed imaging. Section 2 discusses of the current state of the art of high-speed cameras, which includes a comparison between charge-coupled device and complementary metal-oxide semiconductor sensors. The application of high-speed photography to geomechanical experiments is summarized in Sect. 3. Section 4 is concerned with digital optical measurement techniques including photoelastic coating, Moiré, caustics, holographic interferometry, particle image velocimetry, digital image correlation and infrared thermography, in combination with high-speed photography to capture transient phenomena. The last section provides a brief summary and discussion of future directions in the field.

  13. Biochemical component identification by light scattering techniques in whispering gallery mode optical resonance based sensor

    Science.gov (United States)

    Saetchnikov, Vladimir A.; Tcherniavskaia, Elina A.; Saetchnikov, Anton V.; Schweiger, Gustav; Ostendorf, Andreas

    2014-03-01

    Experimental data on detection and identification of variety of biochemical agents, such as proteins (albumin, interferon, C reactive protein), microelements (Na+, Ca+), antibiotic of different generations, in both single and multi component solutions under varied in wide range concentration are represented. Analysis has been performed on the light scattering parameters of whispering gallery mode (WGM) optical resonance based sensor with dielectric microspheres from glass and PMMA as sensitive elements fixed by spin - coating techniques in adhesive layer on the surface of substrate or directly on the coupling element. Sensitive layer was integrated into developed fluidic cell with a digital syringe. Light from tuneable laser strict focusing on and scattered by the single microsphere was detected by a CMOS camera. The image was filtered for noise reduction and integrated on two coordinates for evaluation of integrated energy of a measured signal. As the entrance data following signal parameters were used: relative (to a free spectral range) spectral shift of frequency of WGM optical resonance in microsphere and relative efficiency of WGM excitation obtained within a free spectral range which depended on both type and concentration of investigated agents. Multiplexing on parameters and components has been realized using spatial and spectral parameters of scattered by microsphere light with developed data processing. Biochemical component classification and identification of agents under investigation has been performed by network analysis techniques based on probabilistic network and multilayer perceptron. Developed approach is demonstrated to be applicable both for single agent and for multi component biochemical analysis.

  14. Gabor fusion technique in a Talbot bands optical coherence tomography system.

    Science.gov (United States)

    Bouchal, Petr; Bradu, Adrian; Podoleanu, Adrian Gh

    2012-02-27

    In this paper we show how to advantageously combine two effects to enhance the sensitivity with depth in Fourier domain (FD) optical coherence tomography (OCT): Talbot bands (TB) and Gabor-based fusion (GF) technique. TB operation is achieved by routing the two beams, from the object arm and from the reference arm in the OCT interferometer, along parallel separate paths towards the spectrometer. By adjusting the lateral gap between the two beams in their way towards the spectrometer, the position for the maximum of contrast variation of spectral modulation versus the optical path difference in the interferometer is adjusted. For five values of the focus position, the gap between the two beams is readjusted to reach maximum sensitivity. Then, similar to the procedure employed in the GF technique, a compound image is formed by stitching together the parts of the five images that exhibited maximum brightness. The smaller the diameters of the two beams, the narrower the visibility profile versus depth in Talbot bands, which brings advantages in terms of mirror terms attenuation. However, this leads to a larger spot on the linear camera, which introduces losses, therefore the combined procedure, TB/GF is investigated for four different values of the beam diameters of the two beams. Future cameras with larger pixel size may take full advantage of the TB/GF procedure proposed here.

  15. Fiber optic profenofos sensor based on surface plasmon resonance technique and molecular imprinting.

    Science.gov (United States)

    Shrivastav, Anand M; Usha, Sruthi P; Gupta, Banshi D

    2016-05-15

    A successful approach for the fabrication and characterization of an optical fiber sensor for the detection of profenofos based on surface plasmon resonance (SPR) and molecular imprinting is introduced. Molecular imprinting technology is used for the creation of three dimensional binding sites having complementary shape and size of the specific template molecule over a polymer for the recognition of the same. Binding of template molecule with molecularly imprinted polymer (MIP) layer results in the change in the dielectric nature of the sensing surface (polymer) and is identified by SPR technique. Spectral interrogation method is used for the characterization of the sensing probe. The operating profenofos concentration range of the sensor is from 10(-4) to 10(-1)µg/L. A red shift of 18.7 nm in resonance wavelength is recorded for this profenofos concentration range. The maximum sensitivity of the sensor is 12.7 nm/log (µg/L) at 10(-4)µg/L profenofos concentration. Limit of detection (LOD) of the sensor is found to be 2.5×10(-6)µg/L. Selectivity measurements predict the probe highly selective for the profenofos molecule. Besides high sensitivity due to SPR technique and selectivity due to molecular imprinting, proposed sensor has numerous other advantages like immunity to electromagnetic interference, fast response, low cost and capability of online monitoring and remote sensing of analyte due to the fabrication of the probe on optical fiber.

  16. Gas detection techniques with fiber optical spectrum absorption at near-IR wavelength

    Science.gov (United States)

    Liu, Tiegen; Liu, Kun; Jiang, Junfeng; Peng, Gangding; Wang, Yan; Jia, Dagong; Zhang, Hongxia; Jing, Wencai; Zhang, Yimo

    2010-04-01

    Detection of pollution gas is important in environmental and pollution monitoring, which can be used widely in mining and petrochemical industry. Fiber optical spectrum absorption (FOSA) at near-IR wavelength is widely used in gas detection due to its essential advantages. It has attracted considerable attention, and there are several types and methods in FOSA. Wavelength modulation technique (WMT) is one of them, which will improve the gas detection sensitivity dramatically. This technique can be realized by detecting the intensity of the second-harmonic component signal. Intra-cavity laser spectroscopy (ICLS) is another alternative technique for high sensitivity absorption measurement. With an absorber directly placed within the laser cavity, a short absorption cell can be transformed into a high sensitivity system. But the practical sensitivity is obviously less than the theoretical value. The authors did some works in these fields and have obtained some remarkable progress. With broad reflectors instead of FBG as mirror of the cavity and wavelength sweep technique (WST), several absorption spectra of detected gas can be collected. And the detection sensitivity can be enhanced sharply by averaging the results of each spectrum, with acetylene sensitivity less than 100 ppm . When ICLS is used combined with WST and WMT, the detection sensitivity of acetylene can be enhanced further. The sensitivity is less than 75 ppm. By using FBGs as wavelength references, the absorption wavelength of the detected gas is obtained, which can be used to realize gas recognition. The system is capable of accessing into fiber intelligent sensing network.

  17. Brillouin optical time domain reflectometry for fast detection of dynamic strain incorporating double-edge technique

    Science.gov (United States)

    Shangguan, Mingjia; Wang, Chong; Xia, Haiyun; Shentu, Guoliang; Dou, Xiankang; Zhang, Qiang; Pan, Jian-wei

    2017-09-01

    For the first time, to the best of our knowledge, a direct detection Brillouin optical time-domain reflectometry (BOTDR) is demonstrated for fast distributed dynamic strain sensing incorporating double-edge technique, time-division multiplexing technique and upconversion technique. In order to guarantee the robust stability of the system, the double-edge technique is implemented by using a convert single-channel FPI and a fiber-coupled upconversion single-photon detector, incorporating a time-division multiplexing method. The upconversion single-photon detector is adopted to upconvert the backscattering photons from 1548.1 nm to 863 nm, which is subsequently detected by a Silicon avalanche photodiode (Si-APD). In the experiment, dynamic strain disturbance up to 1.9 mε over 1.5 km of a polarization maintaining fiber is detected at a sampling rate of 30 Hz. An accuracy of ± 30 με and spatial resolution of 0.6 m are realized.

  18. Application of Optical Measurement Techniques During Fabrication and Testing of Liquid Rocket Nozzles

    Science.gov (United States)

    Gradl, Paul R.

    2015-01-01

    This paper presents a series of optical measurement techniques that were developed for use during large-scale fabrication and testing of nozzle components. A thorough understanding of hardware throughout the fabrication cycle and hotfire testing is critical to meet component design intent. Regeneratively cooled nozzles and associated tooling require tight control of tolerances during the fabrication process to ensure optimal performance. Additionally, changes in geometry during testing can affect performance of the nozzle and mating components. Structured light scanning and digital image correlation techniques were used to collect data during the fabrication and test of nozzles, in addition to other engine components. This data was used to analyze deformations data during machining, heat treatment, assembly and testing operations. A series of feasibility experiments were conducted for these techniques that led to use on full scale nozzles during the J-2X upper stage engine program in addition to other engine development programs. This paper discusses the methods and results of these measurement techniques throughout the nozzle life cycle and application to other components.

  19. Measuring higher order optical aberrations of the human eye: techniques and applications

    Directory of Open Access Journals (Sweden)

    L. Alberto V. Carvalho

    2002-11-01

    Full Text Available In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia and higher order aberrations (coma, spherical aberration, etc.. We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.

  20. Digital holographic interferometry: a novel optical calorimetry technique for radiation dosimetry.

    Science.gov (United States)

    Cavan, Alicia; Meyer, Juergen

    2014-02-01

    To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ± 3.45 Gy (corresponding to an uncertainty in the temperature value of ± 8.3 × 10(-4) K). The relative dose fall off was in agreement with treatment planning system modeled data. First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10(-4) m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

  1. All-optical optoacoustic microscopy system based on probe beam deflection technique

    Science.gov (United States)

    Maswadi, Saher M.; Tsyboulskic, Dmitri; Roth, Caleb C.; Glickman, Randolph D.; Beier, Hope T.; Oraevsky, Alexander A.; Ibey, Bennett L.

    2016-03-01

    It is difficult to achieve sub-micron resolution in backward mode OA microscopy using conventional piezoelectric detectors, because of wavefront distortions caused by components placed in the optical path, between the sample and the objective lens, that are required to separate the acoustic wave from the optical beam. As an alternate approach, an optoacoustic microscope (OAM) was constructed using the probe beam deflection technique (PBDT) to detect laserinduced acoustic signals. The all-optical OAM detects laser-generated pressure waves using a probe beam passing through a coupling medium, such as water, filling the space between the microscope objective lens and sample. The acoustic waves generated in the sample propagate through the coupling medium, causing transient changes in the refractive index that deflect the probe beam. These deflections are measured with a high-speed, balanced photodiode position detector. The deflection amplitude is directly proportional to the magnitude of the acoustic pressure wave, and provides the data required for image reconstruction. The sensitivity of the PBDT detector expressed as noise equivalent pressure was 12 Pa, comparable to that of existing high-performance ultrasound detectors. Because of the unimpeded working distance, a high numerical aperture objective lens, i.e. NA = 1, was employed in the OAM to achieve near diffraction-limited lateral resolution of 0.5 μm at 532nm. The all-optical OAM provides several benefits over current piezoelectric detector-based systems, such as increased lateral and axial resolution, higher sensitivity, robustness, and potentially more compatibility with multimodal instruments.

  2. Digital holographic interferometry: A novel optical calorimetry technique for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cavan, Alicia, E-mail: alicia.cavan@cdhb.health.nz [Department of Physics and Astronomy, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand and Christchurch Hospital, Private Bag 4710, Christchurch 8140 (New Zealand); Meyer, Juergen, E-mail: juergen@uw.edu [Department of Radiation Oncology, University of Washington, 1959 Northeast Pacific Street, Box 356043, Seattle, Washington 98195 (United States)

    2014-02-15

    Purpose: To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. Methods: The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. Results: The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ±3.45 Gy (corresponding to an uncertainty in the temperature value of ±8.3 × 10{sup −4} K). The relative dose fall off was in agreement with treatment planning system modeled data. Conclusions: First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10{sup −5} m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

  3. A Novel Noise Free Transmission Technique for Designing 100Gb/s Future Generation Optical Communication System

    DEFF Research Database (Denmark)

    Das, Bhagwan; Abdullah, M.F.L.; Pandey, Bishwajeet

    2017-01-01

    Differential Phase Shift Keying (DPSK) techniques are widely used in designing the high-speed communication systems. However, these techniques still need improvement for long haul communication system design. In this paper, high-speed optical signal transmission and reception system is achieved f...

  4. Bioluminescence : the potential of a non-invasive bio-optical imaging technique and improvement of animal research

    NARCIS (Netherlands)

    Hesselink, J. W.; van Dam, G. M.

    2007-01-01

    Bioluminescence is an optical imaging technique that exploits the emission of photons at specific wavelengths based on energy-dependent reactions catalysed by luciferases. The technique makes it possible to monitor measure, and track biological processes in living animals. A short review is

  5. Bioluminescence : the potential of a non-invasive bio-optical imaging technique and improvement of animal research

    NARCIS (Netherlands)

    Hesselink, J. W.; van Dam, G. M.

    2007-01-01

    Bioluminescence is an optical imaging technique that exploits the emission of photons at specific wavelengths based on energy-dependent reactions catalysed by luciferases. The technique makes it possible to monitor measure, and track biological processes in living animals. A short review is presente

  6. Optical properties of AlGaN nanowires synthesized via ion beam techniques

    Science.gov (United States)

    Parida, Santanu; Magudapathy, P.; Sivadasan, A. K.; Pandian, Ramanathaswamy; Dhara, Sandip

    2017-05-01

    AlGaN plays a vital role in hetero-structure high electron mobility transistors by employing a two-dimensional electron gas as an electron blocking layer in multi-quantum well light emitting diodes. Nevertheless, the incorporation of Al into GaN for the formation of the AlGaN alloy is limited by the diffusion barrier formed by instant nitridation of Al adatoms by reactive atomic N. The incorporation of Al above the miscibility limit, however, can be achieved by the ion beam technique. The well known ion beam mixing (IBM) technique was carried out with the help of Ar+ irradiation for different fluences. A novel approach was also adopted for the synthesis of AlGaN by the process of post-irradiation diffusion (PID) as a comparative study with the IBM technique. The optical investigations of AlGaN nanowires, synthesized via two different methods of ion beam processing, are reported. The effect of irradiation fluence and post-irradiation annealing temperature on the random alloy formation was studied by the vibrational and photoluminescence (PL) spectroscopic studies. Vibrational studies show one-mode phonon behavior corresponding to the longitudinal optical (LO) mode of A1 symmetry [A1(LO)] for the wurtzite phase of AlGaN nanowires in the random alloy model. A maximum Al atomic percentage of ˜6.3%-6.7% was calculated with the help of band bowing formalism from the Raman spectral analysis for samples synthesized in IBM and PID processes. PL studies show the extent of defects present in these samples.

  7. Glow discharge optical emission spectroscopy: a complementary technique to analyze thin electrodeposited polyaniline films

    Energy Technology Data Exchange (ETDEWEB)

    Moutarlier, V. [Institut UTINAM, CNRS-UMR 6213, Université de Franche-Comté, 16 route de Gray, 25030 Besançon (France); Lakard, S., E-mail: sophie.lakard@univ-fcomte.fr [Institut UTINAM, CNRS-UMR 6213, Université de Franche-Comté, 16 route de Gray, 25030 Besançon (France); Patois, T. [Institute of Condensed Matter and Nanosciences, Université Catholique de Louvain, Croix du Sud, 1/4, 1348 Louvain-la-Neuve (Belgium); Lakard, B. [Institut UTINAM, CNRS-UMR 6213, Université de Franche-Comté, 16 route de Gray, 25030 Besançon (France)

    2014-01-01

    Glow Discharge Optical Emission Spectroscopy (GDOES) has been developed to perform depth profiles of thick metallic films, in tens of microns range. GDOES spectroscopy can also be used to analyze thin organic polymer films since this technique has a great potential thanks to its high depth resolution, multi-element capability, sensitivity, and adaptability to solids or films and to conducting or non-conducting samples. In particular thin electrodeposited conducting polymer films remain an unexplored field of investigation for GDOES technique. However GDOES was used in this work to analyze electrodeposited polyaniline films, in addition to other techniques such as profilometry, electron microscopy and X-ray diffraction (XRD). More precisely polyaniline thin films were electrodeposited from HCl solutions and the presence of an anilinium chloride excess at the top surface of the polymer film was demonstrated using GDOES and XRD. Rinsing of these films with water led to the removal of this excess and to the partial dedoping of the polymer film due to the porous structure of polymer films. Polyaniline thin films were also electrodeposited from H{sub 2}SO{sub 4} solutions and an anilinium hydrogen sulfate was similarly observed at the top surface of the polymer. This excess was removed by rinsing, contrary to hydrogen sulfate anions incorporated into the polymer film during the electrochemical polymerization that were not completely expulsed from the polyaniline films as proved using GDOES. - Highlights: • Polyaniline films were electrodeposited from HCl and H{sub 2}SO{sub 4} solutions • Polymer films were analyzed by Glow Discharge Optical Emission Spectroscopy (GDOES) • The incorporation of anions in the films was proved using GDOES depth profiles • The crystalline structure of polyaniline films was modified by water rinsing.

  8. Sub-THz-range linearly chirped signals characterized using linear optical sampling technique to enable sub-millimeter resolution for optical sensing applications.

    Science.gov (United States)

    Wang, Shuai; Fan, Xinyu; Wang, Bin; Yang, Guangyao; He, Zuyuan

    2017-05-01

    Pulse compression technique is a particularly competitive method that enables both high spatial resolution and dynamic range in coherent radar and distributed fiber sensing systems. Up to now, the frequency bandwidths of most pulse compression techniques are restricted to tens of GHz. In this paper, we propose an all-optic sub-THz-range linearly chirped optical source and a large-bandwidth detection system to characterize it. Taking advantage of the chromatic dispersion effect, ultrashort optical pulses are stretched to be ~10 ns linearly chirped pulses with sub-THz range, which yields a large time-bandwidth product of 4500, a high compression ratio of 4167 and a chirp rate of 45 GHz/ns. The generated waveform is characterized with high precision thanks to the large detection bandwidth of linear optical sampling technique. A spatial resolution of 120 μm and an extinction ratio of 20.4 dB is demonstrated by using this technique, which paves the way for ultra-high spatial resolution and long range sensing applications such as LIDAR and optical reflectometry.

  9. Developing new optical imaging techniques for single particle and molecule tracking in live cells

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Wei [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian

  10. Performance improvement of hybrid subcarrier multiplexing optical spectrum code division multiplexing system using spectral direct decoding detection technique

    Science.gov (United States)

    Sahbudin, R. K. Z.; Abdullah, M. K.; Mokhtar, M.

    2009-06-01

    This paper proposes a hybrid subcarrier multiplexing/optical spectrum code division multiplexing (SCM/OSCDM) system for the purpose of combining the advantages of both techniques. Optical spectrum code division multiple-access (OSCDMA) is one of the multiplexing techniques that is becoming popular because of the flexibility in the allocation of channels, ability to operate asynchronously, enhanced privacy and increased capacity in bursty nature networks. On the other hand, subcarrier multiplexing (SCM) technique is able to enhance the channel data rate of OSCDMA systems. In this paper, a newly developed detection technique for the OSCDM called spectral direct decoding (SDD) detection technique is compared mathematically with the AND subtraction detection technique. The system utilizes a new unified code construction named KS (Khazani-Syed) code. The results characterizing the bit-error-rate (BER) show that SDD offers a significant improved performance at BER of 10 -9.

  11. The development of optical microscopy techniques for the advancement of single-particle studies

    Science.gov (United States)

    Marchuk, Kyle

    Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-field imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called "non-blinking" quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to

  12. The development of optical microscopy techniques for the advancement of single-particle studies

    Energy Technology Data Exchange (ETDEWEB)

    Marchuk, Kyle [Iowa State Univ., Ames, IA (United States)

    2013-05-15

    Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-field imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called “non-blinking” quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to

  13. Optical techniques for nanoscale probing and chemical detection in aqueous environments

    Science.gov (United States)

    Pristinski, Denis

    We present an investigation of charge-dependent physical properties of water-soluble synthetic polymers and polymer-based layered structures, using optical detection methods in a visible range. We apply in situ nanoscale optical techniques to study response of polymer systems to changes in pH, polymer concentration, and concentration and type of counterions. This work describes three optical techniques and custom built instrumental setups for nanoscale polymer characterization in aqueous environment. Phase-modulated ellipsometry was applied to determine the refraction coefficient and the thickness of a hydrogel-like polymer layer on a substrate. The present study describes the sensitivity of the phase modulated ellipsometry to errors of measurement and determines conditions for decoupling film thickness and refraction index. It is shown that, for a certain range of film thickness, both the thickness and the refractive index can be determined from a single measurement with high precision. This optimal range of the film thickness is calculated for organic thin films, and the analysis is tested on crosslinked poly(methacrylic acid) polymer films in air and in water. Fluorescent correlation spectroscopy was used to investigate diffusion of a synthetic polyelectrolyte in aqueous solutions. Translational diffusion of Alexa-labeled poly(methacrylic acid) chains was studied in very dilute, 10-4 mg/ml, solutions as a function of polymer charge density and counterion concentration. The results illustrate the utility of the technique for studying hydrodynamic sizes of polyelectrolyte coils in response to variation in solution pH or concentration of salt and polyelectrolytes. We apply surface-enhanced Raman scattering (SERS) for studying of enhancement capabilities of individual silver nanoparticles attached to glass and silicon substrates. Nanoparticles were electrostatically bound to a self-assembled polyallylamine hydrochloride (PAH) monolayer, which was deposited on

  14. Analysis of BER of OFDM in Optical Domain with Different Modulation Techniques

    Directory of Open Access Journals (Sweden)

    A. R. Gifty Arul Marin

    2013-01-01

    Full Text Available In OFDM system, the subcarrier frequencies are chosen so that the subcarriers are orthogonal to each other, meaning that cross talk between the sub channels is eliminated. Priority of OFDM system is given to minimizing the interference or crosstalk among the channels and symbols comprising the data stream. The primary advantage of OFDM is its ability to cope with severe channel conditions like attenuation of high frequencies, narrowband interference and frequency selective fading due to multipath. The existing OFDM systems were modelled based on frequency domain using various modulation techniques in AWGN channel. This is a research analysis to calculate the efficient BER of the OFDM system in the optical domain using BPSK and QPSK modulation techniques. This project can be used for high speed applications requiring more band width. Finally, performance comparison of BPSK and QPSK modulation schemes in OFDM system and the calculation of BER (Bit Error Rate using these modulation techniques is to be done. The entire OFDM system is implemented using SIMULINK tool in MATLAB

  15. Molecular-Based Optical Measurement Techniques for Transition and Turbulence in High-Speed Flow

    Science.gov (United States)

    Bathel, Brett F.; Danehy, Paul M.; Cutler, Andrew D.

    2013-01-01

    photogrammetry (for model attitude and deformation measurement) are excluded to limit the scope of this report. Other physical probes such as heat flux gauges, total temperature probes are also excluded. We further exclude measurement techniques that require particle seeding though particle based methods may still be useful in many high speed flow applications. This manuscript details some of the more widely used molecular-based measurement techniques for studying transition and turbulence: laser-induced fluorescence (LIF), Rayleigh and Raman Scattering and coherent anti-Stokes Raman scattering (CARS). These techniques are emphasized, in part, because of the prior experience of the authors. Additional molecular based techniques are described, albeit in less detail. Where possible, an effort is made to compare the relative advantages and disadvantages of the various measurement techniques, although these comparisons can be subjective views of the authors. Finally, the manuscript concludes by evaluating the different measurement techniques in view of the precision requirements described in this chapter. Additional requirements and considerations are discussed to assist with choosing an optical measurement technique for a given application.

  16. Novel technique for measuring intermodal dispersion in optical fibers using the spectral interference in the Michelson interferometer configuration

    Science.gov (United States)

    Hlubina, Petr

    1999-07-01

    The spectral interference between two modes of an optical fiber, which shows up as a periodic modulation of the source spectrum at its output, cannot be used to measure intermodal dispersion in the optical fiber when the period of modulation is too small to be resolved by a spectrometer. We proposed a novel measuring technique utilizing a tandem configuration of a dispersive Michelson interferometer and a two-mode optical fiber in which the intermodal interference can be restored, and consequently spectral interference fringes can be resolved, even if a low-resolution spectrometer is used. In the tandem configuration of the Michelson interferometer and the two-mode optical fiber, the optical path difference (OPD) in the Michelson interferometer is adjusted close to the group OPD between modes of the optical fiber so that the low-frequency spectral modulation that can be processed is produced. The feasibility of this technique has successfully been demonstrated in obtaining the wavelength dependence of the group OPD between two modes of the optical fiber. Using the Fourier transform method in processing the measured spectral modulations and subtracting the effect of the dispersive Michelson interferometer, the intermodal dispersion of the two-mode optical fiber has been obtained.

  17. New measurement technique for dispersion characterizing optical fibers using low-coherence spectral interferometry with a Michelson interferometer

    Science.gov (United States)

    Hlubina, Petr

    1999-08-01

    Low-coherence spectral interferometry with channelled spectrum detection, extensively used for dispersion characterizing optical fibers, utilizes the fact that the spectral interference between two modes of an optical fiber shows up at its output as a periodic modulation of the source spectrum with the period dependent on the group optical path difference (OPD) between modes. However, this measurement technique cannot be used to measure intermodal dispersion in the optical fiber for which the period of modulation is too small to be resolved by a spectrometer. We proposed and realized a new measurement technique utilizing a tandem configuration of a dispersive Michelson interferometer and the two-mode optical fiber in which the intermodal spectral interference can be resolved even if a low-resolution spectrometer is used. In the tandem configuration of the dispersive Michelson interferometer and the two-mode optical fiber, the OPD in the Michelson interferometer is adjusted close to the group OPD between modes of the optical fiber so that the low-frequency spectral modulation that can be processed is produced. Using the Fourier transform method in processing the measured spectral modulations and subtracting the effect of the dispersive Michelson interferometer, the intermodal dispersion of the two-mode optical fiber over a limited spectral region has been obtained.

  18. Measurement of the optical properties of skin using terahertz time-domain spectroscopic techniques

    Science.gov (United States)

    Wilmink, Gerald J.; Ibey, Bennett L.; Tongue, Thomas; Schulkin, Brian; Peralta, Xomalin; Rivest, Benjamin D.; Haywood, Eric C.; Roach, William P.

    2010-02-01

    Terahertz (THz) radiation is increasingly being used in biomedical imaging and spectroscopy applications. These techniques show tremendous promise to provide new sophisticated tools for the improved detection of skin cancer. However, despite recent efforts to develop these applications, few studies have been conducted to characterize the optical properties of skin at THz frequencies. Such information is required to better understand THz-tissue interactions, and is critical for determining the feasibility of proposed applications. In this study, we have developed and tested a THz time-domain spectroscopy system. We used this system to acquire the optical properties for fresh and frozen/thawed excised porcine skin from 0.1 to 2.0 THz. Results show that the index of refraction (n) for both frozen and fresh skin decreases with frequency. For frozen skin, n equals 2.5 at 0.1 THz and 2.0 at 2.0 THz, and for fresh skin equals 2.0 at 0.1 THz and 1.7 at 2.0 THz. Values for the absorption coefficient (μa) increase with frequency for both frozen and fresh skin. Frozen skin exhibits μa values equal to 56 cm-1 at 0.1 THz and 550 cm-1 at 2.0 THz, whereas fresh skin exhibits values of 56 cm-1 at 0.1 THz and 300 cm-1 at 2.0 THz. Assuming the optical penetration depth (δ) is inversely proportional to μa (absorption-dominated interactions), THz radiation has limited δ in skin (200 μm at 0.1 THz to 40 μm at 2.0 THz). These results suggest that applications exploiting THz radiation show the most promise for investigating superficial tissues.

  19. Biophotonic endoscopy: a review of clinical research techniques for optical imaging and sensing of early gastrointestinal cancer.

    Science.gov (United States)

    Coda, Sergio; Siersema, Peter D; Stamp, Gordon W H; Thillainayagam, Andrew V

    2015-10-01

    Detection, characterization, and staging constitute the fundamental elements in the endoscopic diagnosis of gastrointestinal diseases, but histology still remains the diagnostic gold standard. New developments in endoscopic techniques may challenge histopathology in the near future. An ideal endoscopic technique should combine a wide-field, "red flag" screening technique with an optical contrast or microscopy method for characterization and staging, all simultaneously available during the procedure. In theory, biophotonic advances have the potential to unite these elements to allow in vivo "optical biopsy." These techniques may ultimately offer the potential to increase the rates of detection of high risk lesions and the ability to target biopsies and resections, and so reduce the need for biopsy, costs, and uncertainty for patients. However, their utility and sensitivity in clinical practice must be evaluated against those of conventional histopathology. This review describes some of the most recent applications of biophotonics in endoscopic optical imaging and metrology, along with their fundamental principles and the clinical experience that has been acquired in their deployment as tools for the endoscopist. Particular emphasis has been placed on translational label-free optical techniques, such as fluorescence spectroscopy, fluorescence lifetime imaging microscopy (FLIM), two-photon and multi-photon microscopy, second harmonic generation (SHG) and third harmonic generation (THG) imaging, optical coherence tomography (OCT), diffuse reflectance, Raman spectroscopy, and molecular imaging.

  20. Fabricate Optical Microfiber by Using Flame Brushing Technique and Coated with Polymer Polyaniline for Sensing Application

    Science.gov (United States)

    Razak, N. A.; Hamida, B. A.; Irawati, N.; Habaebi, M. H.

    2017-06-01

    Adiabaticity is one of the essential criteria in producing good fabricated tapered fibers. Good tapered fibers can be use in sensor application such as humidity sensor, temperature sensor and refractive index sensor. In this paper, good tapering silica fiber is produced by using flame brushing technique and then, the microfiber is coated with polymer Polyaniline (PAni) to sense different type of alcohols with different concentrations. The outcome of this experiment gives excellent repeatability in the detection of alcohol sensing with a sensitivity of 0.1332 μW/% and a resolution of 3.764%. In conclusion, conducting polymer coated optical microfiber sensor for alcohol detection with low cost, effective and simple set-up was successfully achieved in this study.

  1. Optically stimulated luminescence from quartz measured using the linear modulation technique

    DEFF Research Database (Denmark)

    Bulur, E.; Bøtter-Jensen, L.; Murray, A.S.

    2000-01-01

    The optically stimulated luminescence (OSL) from heated natural quartz has been investigated using the linear modulation technique (LMT), in which the excitation light intensity is increased linearly during stimulation. In contrast to conventional stimulation, which usually produces a monotonically...... stimulated component occurs at a shorter time. This allows the separation of the overlapping OSL components, which are assumed to originate from different traps. The LM-OSL curve from quartz shows an initial peak Followed by a broad one. Deconvolution using curve fitting has shown that the composite OSL...... curve from quartz can be approximated well by using a linear combination of first-order peaks. In addition to the three known components, i.e. fast, medium and slow components from continuous-wave-OSL studies, an additional slow component is also identified for the first time. The dose responses...

  2. Structural, Optical and Electrical Properties of Thin Films Using Nebulizer Spray Pyrolysis Technique

    Directory of Open Access Journals (Sweden)

    R. Mariappan

    2013-01-01

    Full Text Available thin films have been deposited on glass substrates at substrate temperature 400°C through nebulizer spray pyrolysis technique. X-ray diffraction (XRD analysis shows that the films structure is changed from hexagonal to tetragonal. The high-resolution scanning electron microscopy (HRSEM studies reveal that the substrate is well covered with a number of grains indicating compact morphology with an average grain size 50–79 nm. Energy dispersive X-ray analysis (EDAX reveals the average ratio of the atomic percentage. Optical transmittance study shows the presence of direct transition. Band gap energy decreases from 3.33 to 2.87 eV with respect to the rise of Sn content. The electrical resistivity of the thin films was found to be 106 Ω-m.

  3. Developments in optically stimulated luminescence techniques for dating and retrospective dosimetry

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Murray, A.S.

    1999-01-01

    Optically stimulated luminescence signals from natural quartz and feldspar are now used routinely in dating geological and archaeological materials. More recently they have also been employed in accident dosimetry, i.e. the retrospective assessment of doses received as a result of a nuclear...... accident. Since 1990, the exploration of this wide variety of applications has driven an intensive investigation and development programme at Riso in measurement facilities and techniques. This paper reviews some of the outcomes of this programme, including (i) optimisation of stimulation and emission...... windows, and detection sensitivity, (ii) experience with various stimulation light sources, including filtered incandescent lamps and high intensity light emitting diodes and laser diodes (infrared at 830-850 nm, blue-green at 420-550 nm and blue at 470 nm). Also discussed are recently developed high...

  4. Optical double image encryption employing a pseudo image technique in the Fourier domain

    Science.gov (United States)

    Guo, Changliang; Liu, Shi; Sheridan, John T.

    2014-06-01

    A novel optical encryption method is proposed involving double image encryption in which one image is introduced as the pseudo image while the other is the original object image. The Double Random Phase Encoding technique is used to encrypt both the pseudo and object images into complex images. A unique binary image is then employed to first generate the random phase key for the object image encryption and then to embed the encrypted object image into the encrypted pseudo image, which acts as host image. Both the second random phase mask used for encoding the pseudo image and the binary image act as encryption keys. If an attacker attempts to crack the random phase key and decrypt the original object image, the pseudo image will be obtained instead. Simulation results and robustness tests are performed which demonstrate the feasibility of the algorithm.

  5. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  6. Fluorescence measurements for evaluating the application of multivariate analysis techniques to optically thick environments.

    Energy Technology Data Exchange (ETDEWEB)

    Reichardt, Thomas A.; Timlin, Jerilyn Ann; Jones, Howland D. T.; Sickafoose, Shane M.; Schmitt, Randal L.

    2010-09-01

    Laser-induced fluorescence measurements of cuvette-contained laser dye mixtures are made for evaluation of multivariate analysis techniques to optically thick environments. Nine mixtures of Coumarin 500 and Rhodamine 610 are analyzed, as well as the pure dyes. For each sample, the cuvette is positioned on a two-axis translation stage to allow the interrogation at different spatial locations, allowing the examination of both primary (absorption of the laser light) and secondary (absorption of the fluorescence) inner filter effects. In addition to these expected inner filter effects, we find evidence that a portion of the absorbed fluorescence is re-emitted. A total of 688 spectra are acquired for the evaluation of multivariate analysis approaches to account for nonlinear effects.

  7. Optical Biosensor Based on Microbendings Technique: An Optimized Mean to Measure the Bone Strength

    Directory of Open Access Journals (Sweden)

    Preeti Singh

    2014-01-01

    Full Text Available Osteoporosis, a disease in humans, reduces bone mineral density. The microarchitecture of the bone gets deteriorated with change in variety of proteins in the bone. Therefore, a quantitative assessment of the strength of human bone, considering its structural properties and degradation due to aging, disease, and therapeutic treatment, becomes an integral part of the bioengineering studies. This paper presents a model of fiber optic biosensors (FOBs which utilizes microbending technique to measure the strength of the bone. In parallel, an artificial neural network (ANN based test bench has been developed for the optimization of FOBs strain measurement in orthoapplications using MATLAB. The performance accuracy of the given model appears to be considerable in ensuring the detection of the onset of osteoporosis.

  8. Optical techniques for the detection of extrasolar planets - A critical review

    Science.gov (United States)

    Matloff, G. L.; Fennelly, A. J.

    1976-01-01

    Proposed optical techniques of extrasolar planet detection are discussed and compared. These include terrestrial, orbital, and moon-based systems. Terrestrial systems include ground-level searches for random eclipses of primaries and 'light' echoes of stellar flares from companion planets as well as balloon-mounted telescopes operating in the stratosphere used in conjunction with orbital occulters. Space telescopes considered are multimirror systems simulating huge mirror diameters and single-mirror telescopes, such as the 3-meter Large Space Telescope, used in conjunction with occulters. Although very modest systems are capable of detecting extrasolar planets, the amount of information we can gather regarding these worlds is a function of system complexity and program duration.

  9. A new Generation of Spectrometer Calibration Techniques based on Optical Frequency Combs

    CERN Document Server

    Schmidt, Piet O; Kimeswenger, Stefan

    2007-01-01

    Typical astronomical spectrographs have a resolution ranging between a few hundred to 200.000. Deconvolution and correlation techniques are being employed with a significance down to 1/1000 th of a pixel. HeAr and ThAr lamps are usually used for calibration in low and high resolution spectroscopy, respectively. Unfortunately, the emitted lines typically cover only a small fraction of the spectrometer's spectral range. Furthermore, their exact position depends strongly on environmental conditions. A problem is the strong intensity variation between different (intensity ratios {>300). In addition, the brightness of the lamps is insufficient to illuminate a spectrograph via an integrating sphere, which in turn is important to calibrate a long-slit spectrograph, as this is the only way to assure a uniform illumination of the spectrograph pupil. Laboratory precision laser spectroscopy has experienced a major advance with the development of optical frequency combs generated by pulsed femto-second lasers. These lase...

  10. Measurements of nonlinear optical properties of PVDF/ZnO using Z-scan technique

    Energy Technology Data Exchange (ETDEWEB)

    Shanshool, Haider Mohammed, E-mail: haidshan62@gmail.com [Ministry of Science and Technology, Baghdad (Iraq); Yahaya, Muhammad [School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Selangor (Malaysia); Yunus, Wan Mahmood Mat [Department of Physics, Faculty of Science, University Putra Malaysia, Serdang (Malaysia); Abdullah, Ibtisam Yahya [Department of Physics, College of Science, University of Mosul, Mosul (Iraq)

    2015-10-15

    The nonlinear optical properties of ZnO nanoparticles dispersed in poly (vinylidene fluoride) (PVDF) polymer are investigated. PVDF/ZnO nanocomposites were prepared by mixing different concentrations of ZnO nanoparticles, as the filler, with PVDF, as the polymer matrix, using casting method. Acetone was used as a solvent for the polymer. FTIR spectra of the samples were analyzed thus confirming the formation of α and β phases. The absorbance spectra of the samples were obtained, thereby showing high absorption in the UV region. The linear absorption coefficient was calculated. The single-beam Z-scan technique was used to measure the nonlinear refractive index and the nonlinear absorption coefficient of the PVDF/ZnO nanocomposite samples. We observed that the nonlinear refractive index is in the order of 10{sup -13} cm{sup 2}/W with the negative sign, whereas the nonlinear absorption coefficient is in the order of 10{sup -8} cm/W. (author)

  11. Research on fiber-optic interferometric hydrophone array using frequency division multiplying technique

    Institute of Scientific and Technical Information of China (English)

    CAO Jianian; LI Xuyou; WANG Zhaoxia; LUO Jicheng; FU Lintai

    2001-01-01

    From the point of view of system design, a configuration of fiber-optic interferometric hydrophone array and its modulation and demodulation approach using frequency division multiplexing technique based on Phase Generated Carrier (PGC) is introduced. And the emphasis on demonstrating the relationship among the number of units N, the detectable signal amplitude D and the detectable frequency ωs through analyzing the frequency spectrum of the output signal of the J × K array and the key factor which restricts N, D, ωo for increasing are presented. The maximum phase shift and the law of its variation according to frequency are specially analyzed. The results induced from some relative theory were verified by experiments.

  12. Effect of thickness on optical properties of nickel vertical posts deposited by GLAD technique

    Science.gov (United States)

    Potočnik, J.; Nenadović, M.; Bundaleski, N.; Popović, M.; Rakočević, Z.

    2016-12-01

    Nickel (Ni) thin films of different thicknesses (25 nm to 150 nm) were deposited on glass substrates using Glancing Angle Deposition technique. Characterization of obtained Ni films was performed by scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, spectroscopic ellipsometry and by four-point probe method. Variations in optical parameters with thickness correlated with structural, chemical and electrical properties of nanostructured nickel thin films were studied. The results showed that deposit is porous and consists of nano-scaled columns, which grow perpendicular to the substrate. It was found that the size of the columns and the surface roughness change with film thickness. Spectroscopic ellipsometry revealed that the refractive index and extinction coefficient varied with thickness, which can be correlated with changes in microstructure of Ni films. Additionally, the relationship between the film microstructure and its resistivity was also analyzed. It was found that the variations in Ni films resistivity could be attributed to the changes in the width of the columns. The increasing of layer thickness leads to overall decrease of optical resistivity of nickel thin films.

  13. Optical Coherence Tomography Angiography: Employing a Novel Technique for Investigation in Vogt-Koyanagi-Harada Disease

    Directory of Open Access Journals (Sweden)

    Panagiotis Giannakouras

    2017-07-01

    Full Text Available Purpose: To report a case of Vogt-Koyanagi-Harada (VKH disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA. Methods: Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT were performed at baseline, as well as OCTA. Results: A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. Conclusions and Importance: VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.

  14. Comparative study on structural and optical properties of CdS films fabricated by three different low-cost techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ravichandran, K. [P.G. and Research Department of Physics, AVVM. Sri Pushpam College, Poondi, Thanjavur District, Tamil Nadu 613503 (India)], E-mail: kkr1365@yahoo.com; Philominathan, P. [P.G. and Research Department of Physics, AVVM. Sri Pushpam College, Poondi, Thanjavur District, Tamil Nadu 613503 (India)

    2009-03-15

    Highly crystalline and transparent cadmium sulphide films were fabricated at relatively low temperature by employing an inexpensive, simplified spray technique using perfume atomizer (generally used for cosmetics). The structural, surface morphological and optical properties of the films were studied and compared with that prepared by conventional spray pyrolysis using air as carrier gas and chemical bath deposition. The films deposited by the simplified spray have preferred orientation along (1 0 1) plane. The lattice parameters were calculated as a = 4.138 A and c = 6.718 A which are well agreed with that obtained from the other two techniques and also with the standard data. The optical transmittance in the visible range and the optical band gap were found as 85% and 2.43 eV, respectively. The structural and optical properties of the films fabricated by the simplified spray are found to be desirable for opto-electronic applications.

  15. Low power optical limiting studies on nanocrystalline benzimidazole thin films prepared by modified liquid phase growth technique

    Indian Academy of Sciences (India)

    P A Praveen; S P Prabhakaran; R Ramesh Babu; K Sethuraman; K Ramamurthi

    2015-06-01

    In the present work, benzimidazole (BMZ), a well known nonlinear optical material, thin films were deposited using the modified liquid phase growth technique at different solution temperatures. The prepared samples were subjected to spectral, structural and surface analyses. Linear optical properties and third-order optical nonlinearity of the deposited BMZ thin films were analysed using UV–visible–NIR spectrum and -scan technique, respectively. The experimental results show that the BMZ films exhibit reverse saturable absorption and positive nonlinearity at 650 nm CW laser of power 5 mW. The measured third-order nonlinear susceptibility of the films is about 10−10 esu. Optical limiting studies were performed using the same laser source and the potentiality of the BMZ films is reported.

  16. Generation and distribution of a wide-band continuously tunable millimeter-wave signal with an optical external modulation technique

    Science.gov (United States)

    Qi, Guohua; Yao, Jianping; Seregelyi, J.; Paquet, S.; Belisle, C.

    2005-10-01

    A new technique to generate and distribute a wide-band continuously tunable millimeter-wave signal using an optical external modulator and a wavelength-fixed optical notch filter is proposed. The optical intensity modulator is biased to suppress the odd-order optical sidebands. The wavelength-fixed optical notch filter is then used to filter out the optical carrier. Two second-order optical sidebands are obtained at the output of the notch filter. A millimeter-wave signal that has four times the frequency of the microwave drive signal is generated by beating the two second-order optical sidebands at a photodetector. Since no tunable optical filter is used, the system is easy to implement. A system using an LiNbO3 intensity modulator and a fiber Bragg grating filter is built. A stable and high spectral purity millimeter-wave signal tunable from 32 to 50 GHz is obtained by tuning the microwave drive signal from 8 to 12.5 GHz. The integrity of the generated millimeter-wave signal is maintained after transmission over a 25-km standard single-mode fiber. Theoretical analysis on the harmonic suppression with different modulation depths and filter attenuations is also discussed.

  17. Prism coupling technique investigation of elasto-optical properties of thin polymer films

    NARCIS (Netherlands)

    Ay, Feridun; Kocabas, Askin; Kocabas, Coskun; Aydinli, Atilla; Agan, Sedat

    2004-01-01

    The use of thin polymer films in optical planar integrated optical circuits is rapidly increasing. Much interest, therefore, has been devoted to characterizing the optical and mechanical properties of thin polymer films. This study focuses on measuring the elasto-optical properties of three differen

  18. Fiber Transmission Stabilization by Optical Heterodyning Techniques and Synchronization of Mode-Locked Lasers Using Two Spectral Lines

    CERN Document Server

    Staples, J W

    2005-01-01

    Stabilization of the transit time through a glass fiber using an optical heterodyne technique promises to provide jitter reduction down to the few femtosecond level using inexpensive commodity hardware. An acousto-optical frequency shifter provides the optical frequency offset that is used to downconvert phase shifts at optical frequency to equivalent phase shifts at radio frequency which are used to close a phase-lock loop driving a piezoelectric phase shifter. Using the stabilized fiber transmission medium, two spectral lines of a mode locked laser lock two low-power CW lasers which are transmitted to a receiver which phase locks the same spectral lines of a second mode-locked laser to the first. The optical transmission system operates at low power and is linear, providing excellent signal-to-noise ratio and allows many signals to be transmitted without mutual interference. Experimental results will be presented.

  19. Bilateral optic neuritis in a child diagnosed with Gd-enhanced MR imaging using fat-suppression technique

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, K.; Ogawa, R.; Furusawa, T.; Sakai, K. [Dept. of Radiology, Niigata Univ. School of Medicine, Niigata (Japan); Ito, J.; Tokiguchi, S. [Dept. of Radiology, Niigata University School of Dentistry (Japan); Takagi, M. [Dept. of Ophthalmology, Niigata Univ. School of Medicine (Japan)

    1999-05-01

    A 4-year-old boy developed bilateral optic neuritis. Although precise neuro-ophthalmological evaluation was difficult, the diagnosis was made with gadolinium-enhanced MR imaging using fat-suppression technique in the initial stage of the disease. Enhancement and enlargement of the intraorbital and intracanalicular optic nerve were demonstrated bilaterally as well as protrusion of the optic nerve head. The disease responded dramatically to intravenous steroid therapy. The etiologies in children usually differ from those in adolescent and adult patients. (orig.) With 1 fig., 13 refs.

  20. Experimental measurement of a time-varying optical path difference using the small-aperture beam technique

    Science.gov (United States)

    Hugo, Ronald J.; Jumper, Eric J.

    1993-12-01

    This paper discusses the use of time series of the jitter angle of multiple, small-aperture probe beams as they emerge from a turbulent, optically-active flow field to quantify the time-varying optical path difference (OPD). Techniques to reconstruct a complete time series of instantaneous realizations of the OPD are first applied to a numerically-generated flow field and then to an experimental flow field. The flow field studied was that for the transitionally- turbulent region of a heated, two-dimensional jet. From these OPD histories spatial and temporal frequencies characterizing the OPD's are extracted. The relevance of these results to adaptive-optic devices is discussed.

  1. Observationally-constrained estimates of aerosol optical depths (AODs) over East Asia via data assimilation techniques

    Science.gov (United States)

    Lee, K.; Lee, S.; Song, C. H.

    2015-12-01

    Not only aerosol's direct effect on climate by scattering and absorbing the incident solar radiation, but also they indirectly perturbs the radiation budget by influencing microphysics and dynamics of clouds. Aerosols also have a significant adverse impact on human health. With an importance of aerosols in climate, considerable research efforts have been made to quantify the amount of aerosols in the form of the aerosol optical depth (AOD). AOD is provided with ground-based aerosol networks such as the Aerosol Robotic NETwork (AERONET), and is derived from satellite measurements. However, these observational datasets have a limited areal and temporal coverage. To compensate for the data gaps, there have been several studies to provide AOD without data gaps by assimilating observational data and model outputs. In this study, AODs over East Asia simulated with the Community Multi-scale Air Quality (CMAQ) model and derived from the Geostationary Ocean Color Imager (GOCI) observation are interpolated via different data assimilation (DA) techniques such as Cressman's method, Optimal Interpolation (OI), and Kriging for the period of the Distributed Regional Aerosol Gridded Observation Networks (DRAGON) Campaign (March - May 2012). Here, the interpolated results using the three DA techniques are validated intensively by comparing with AERONET AODs to examine the optimal DA method providing the most reliable AODs over East Asia.

  2. Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study.

    Science.gov (United States)

    Larin, Kirill V; Motamedi, Massoud; Ashitkov, Taras V; Esenaliev, Rinat O

    2003-05-21

    Noninvasive monitoring of blood glucose concentration in diabetic patients would significantly reduce complications and mortality associated with this disease. In this paper, we experimentally and theoretically studied specificity of noninvasive blood glucose monitoring with the optical coherence tomography (OCT) technique. OCT images and signals were obtained from skin of Yucatan micropigs and New Zealand rabbits. Obtained results demonstrate that: (1) several body osmolytes may change the refractive index mismatch between the interstitial fluid (ISF) and scattering centres in tissue, however the effect of the glucose is approximately one to two orders of magnitude higher; (2) an increase of the ISF glucose concentration in the physiological range (3-30 mM) may decrease the scattering coefficient by 0.22% mM(-1) due to cell volume change; (3) stability of the OCT signal slope is dependent on tissue heterogeneity and motion artefacts; and (4) moderate skin temperature fluctuations (+/- 1 degree C) do not decrease accuracy and specificity of the OCT-based glucose sensor, however substantial skin heating or cooling (several degrees C) significantly change the OCT signal slope. These results suggest that the OCT technique may provide blood glucose concentration monitoring with sufficient specificity under normal physiological conditions.

  3. COMPENSATION OF OUTPUT SIGNAL TEMPERATURE DEPENDENCE IN HOMODYNE DEMODULATION TECHNIQUE FOR PHASE FIBER-OPTIC SENSORS

    Directory of Open Access Journals (Sweden)

    M. V. Mekhrengin

    2015-03-01

    Full Text Available Modified phase-generated carrier homodyne demodulation technique for fiber-optic sensors is presented. Nowadays phase-generated carrier homodyne demodulation technique is one of the most widespread. One of its drawbacks is the temperature dependence of the output signal because of the modulator scale factor temperature dependence. In order to compensate this dependence an automatic adjustment of the phase modulation depth is necessary. To achieve the result, additional harmonics analysis is used with the help of the Bessel functions. For this purpose the known demodulation scheme is added with the branch, where interferometric signal is multiplied by the third harmonic of the modulation signal. The deviation of optimal ratio of odd harmonics is used as a feedback signal for adjusting the modulation depth. Unwanted emissions arise in the feedback signal, when the third harmonic possesses a value close to zero. To eliminate unwanted emission in the feedback signal, the principle scheme is added with one more branch, where interferometric signal is multiplied by the forth harmonic of the modulation signal. The deviation of optimal ratio of even harmonics is used as a feedback signal alternately with the deviation of optimal ratio of odd harmonics. A mathematical model of the algorithm is designed using the MATLAB package. Results of modeling have confirmed that suggested method gives the possibility for an automatic adjustment of the phase modulation depth and makes it possible to compensate temperature dependence for the modulator scale factor and output signal magnitude.

  4. Measurement of five-degrees-of-freedom error motions for a micro high-speed spindle using an optical technique

    Science.gov (United States)

    Murakami, Hiroshi

    2011-05-01

    We present an optical technique to measure five-degree-of-freedom error motions of a high-speed microspindle. The measurement system consists of a rod lens, a ball lens, four divided laser beams, and multiple divided photodiodes. When the spindle rotates with its concomitant rotation errors, the rod and ball lenses, which are mounted to the chuck of the spindle, are displaced, and this displacement is measured using an optical technique. In this study, the measuring system is manufactured for trial and is experimentally evaluated. The results clarify that the measuring system has a resolution of 5 nm and can be used to evaluate micro spindle rotation errors.

  5. [Progress of electro-optic polymer in the field of generation and detection of Terahertz waves by all-optical technique].

    Science.gov (United States)

    Wang, Xuan; Jiang, Qiang; Wang, Yue; Zhang, Wen-long; Li, Zhi-yuan

    2014-08-01

    Research on and development of the high amplitude, broadband terahertz system based on ultra-short pulse, low-power laser system is a hot spot in the field of terahertz. So far, for all the reported THz bandwidths broader than 10 THz, there always exist strong dispersion and absorption gaps associated with the lattice resonance in either the photoconductive materials or crystalline EO materials. If such THz sources and detectors are employed in spectroscopic studies, spectral information in these gaps cannot be extracted. One of the advantages of using amorphous electro-optic polymer films as THz emitters and sensors is that there is no dispersion or absorption resulting from the lattice resonance effect, making a gap-free THz spectrum possible. Another advantage of electro-optic polymer films is the ease of fabrication and handling, in contrast to the extremely thin crystalline electro-optic materials used for existing broadband THz system. In addition, we can engineer the electro-optic polymeric materials to achieve small phase mismatch and high electro-optic coefficients such that brightness and broad bandwidth of THz radiation can be obtained. In this thesis a theoretical description of electro-optic effect based on electro-optic polymer and the second- order nonlinear chromophores synthesis is reviewed. In the past 20 years, progress in electro-optic polymer in the field of generating and detecting terahertz radiation by all-optical techniques is summarized, including the terahertzs systems based on copolymer and the guest-host polymer induced by Titanium doped sapphire femtosecond laser and based on the guest-host polymer at communication wavelengths.

  6. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique.

    Science.gov (United States)

    Khan, Md Rajibur Rahaman; Kang, Shin-Won

    2016-11-09

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal's pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R² is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry-Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.

  7. Monitoring of Emissions From a Refinery Tank Farm Using a Combination of Optical Remote Sensing Techniques

    Science.gov (United States)

    Polidori, A.; Tisopulos, L.; Pikelnaya, O.; Mellqvist, J.; Samuelsson, J.; Marianne, E.; Robinson, R. A.; Innocenti, F.; Finlayson, A.; Hashmonay, R.

    2016-12-01

    Despite great advances in reducing air pollution, the South Coast Air Basin (SCAB) still faces challenges to attain federal health standards for air quality. Refineries are large sources of ozone precursors and, hence contribute to the air quality problems of the region. Additionally, petrochemical facilities are also sources of other hazardous air pollutants (HAP) that adversely affect human health, for example aromatic hydrocarbons. In order to assure safe operation, decrease air pollution and minimize population exposure to HAP the South Coast Air Quality Management District (SCAQMD) has a number of regulations for petrochemical facilities. However, significant uncertainties still exist in emission estimates and traditional monitoring techniques often do not allow for real-time emission monitoring. In the fall of 2015 the SCAQMD, Fluxsense Inc., the National Physical Laboratory (NPL), and Atmosfir Optics Ltd. conducted a measurement study to characterize and quantify gaseous emissions from the tank farm of one of the largest oil refineries in the SCAB. Fluxsense used a vehicle equipped with Solar Occultation Flux (SOF), Differential Optical Absorption Spectroscopy (DOAS), and Extractive Fourier Transform Infrared (FTIR) spectroscopy instruments. Concurrently, NPL operated their Differential Absorption Lidar (DIAL) system. Both research groups quantified emissions from the entire tank farm and identified fugitive emission sources within the farm. At the same time, Atmosfir operated an Open Path FTIR (OP-FTIR) spectrometer along the fenceline of the tank farm. During this presentation we will discuss the results of the emission measurements from the tank farm of the petrochemical facility. Emission rates resulting from measurements by different ORS methods will be compared and discussed in detail.

  8. Adaptive gain, equalization, and wavelength stabilization techniques for silicon photonic microring resonator-based optical receivers

    Science.gov (United States)

    Palermo, Samuel; Chiang, Patrick; Yu, Kunzhi; Bai, Rui; Li, Cheng; Chen, Chin-Hui; Fiorentino, Marco; Beausoleil, Ray; Li, Hao; Shafik, Ayman; Titriku, Alex

    2016-03-01

    Interconnect architectures based on high-Q silicon photonic microring resonator devices offer a promising solution to address the dramatic increase in datacenter I/O bandwidth demands due to their ability to realize wavelength-division multiplexing (WDM) in a compact and energy efficient manner. However, challenges exist in realizing efficient receivers for these systems due to varying per-channel link budgets, sensitivity requirements, and ring resonance wavelength shifts. This paper reports on adaptive optical receiver design techniques which address these issues and have been demonstrated in two hybrid-integrated prototypes based on microring drop filters and waveguide photodetectors implemented in a 130nm SOI process and high-speed optical front-ends designed in 65nm CMOS. A 10Gb/s powerscalable architecture employs supply voltage scaling of a three inverter-stage transimpedance amplifier (TIA) that is adapted with an eye-monitor control loop to yield the necessary sensitivity for a given channel. As reduction of TIA input-referred noise is more critical at higher data rates, a 25Gb/s design utilizes a large input-stage feedback resistor TIA cascaded with a continuous-time linear equalizer (CTLE) that compensates for the increased input pole. When tested with a waveguide Ge PD with 0.45A/W responsivity, this topology achieves 25Gb/s operation with -8.2dBm sensitivity at a BER=10-12. In order to address microring drop filters sensitivity to fabrication tolerances and thermal variations, efficient wavelength-stabilization control loops are necessary. A peak-power-based monitoring loop which locks the drop filter to the input wavelength, while achieving compatibility with the high-speed TIA offset-correction feedback loop is implemented with a 0.7nm tuning range at 43μW/GHz efficiency.

  9. Evaluating interfacial adhesion properties of Pt/Ti thin-film by using acousto-optic technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hae Sung [Graduate School of Automotive Engineering, Seoul National University of Science and Technology, Seoul (Korea, Republic of); Didie, David; Yoshida, Sanichiro [Dept. of Chemistry and Physics, Southeastern Louisiana University, Hammond (United States); Park, Ik Keun [Dept. of Mechanical and Automotive Engineering, Seoul National University of Science and Technology, Seoul (Korea, Republic of)

    2016-06-15

    We propose an acousto-optic technique for the nondestructive evaluation of adhesion properties of a Pt/Ti thin-film interface. Since there are some problems encountered when using prevailing techniques to nondestructively evaluate the interfacial properties of micro/nano-scale thin-films, we applied an interferometer that combined the acoustic and optical methods. This technique is based on the Michelson interferometer but the resultant surface of the thin film specimen makes interference instead of the mirror when the interface is excited from the acoustic transducer at the driving frequency. The thin film shows resonance-like behavior at a certain frequency range, resulting in a low-contrast fringe pattern. Therefore, we represented quantitatively the change in fringe pattern as a frequency spectrum and discovered the possibility that the interfacial adhesion properties of a thin film can be evaluated using the newly proposed technique.

  10. Nonlinear optical properties of natural laccaic acid dye studied using Z-scan technique

    CSIR Research Space (South Africa)

    Zongo, S

    2015-08-01

    Full Text Available We have investigated the nonlinear optical properties, including the optical limiting behaviour for five different concentrations of laccaic acid dye in solution and a thin film obtained through doping in poly (methyl methacrylate) (PMMA) polymer...

  11. Techniques for Effective Optical Noise Rejection in Amplitude-Modulated Laser Optical Radars for Underwater Three-Dimensional Imaging

    Directory of Open Access Journals (Sweden)

    Francucci M

    2010-01-01

    Full Text Available Amplitude-modulated (AM laser imaging is a promising technology for the production of accurate three-dimensional (3D images of submerged scenes. The main challenge is that radiation scattered off water gives rise to a disturbing signal (optical noise that degrades more and more the quality of 3D images for increasing turbidity. In this paper, we summarize a series of theoretical findings, that provide valuable hints for the development of experimental methods enabling a partial rejection of optical noise in underwater imaging systems. In order to assess the effectiveness of these methods, which range from modulation/demodulation to polarimetry, we carried out a series of experiments by using the laboratory prototype of an AM 3D imager ( = 405 nm for marine archaeology surveys, in course of realization at the ENEA Artificial Vision Laboratory (Frascati, Rome. The obtained results confirm the validity of the proposed methods for optical noise rejection.

  12. Techniques for Effective Optical Noise Rejection in Amplitude-Modulated Laser Optical Radars for Underwater Three-Dimensional Imaging

    Directory of Open Access Journals (Sweden)

    R. Ricci

    2010-01-01

    Full Text Available Amplitude-modulated (AM laser imaging is a promising technology for the production of accurate three-dimensional (3D images of submerged scenes. The main challenge is that radiation scattered off water gives rise to a disturbing signal (optical noise that degrades more and more the quality of 3D images for increasing turbidity. In this paper, we summarize a series of theoretical findings, that provide valuable hints for the development of experimental methods enabling a partial rejection of optical noise in underwater imaging systems. In order to assess the effectiveness of these methods, which range from modulation/demodulation to polarimetry, we carried out a series of experiments by using the laboratory prototype of an AM 3D imager (λ = 405 nm for marine archaeology surveys, in course of realization at the ENEA Artificial Vision Laboratory (Frascati, Rome. The obtained results confirm the validity of the proposed methods for optical noise rejection.

  13. Axial Phase-Darkfield-Contrast (APDC), a new technique for variable optical contrasting in light microscopy.

    Science.gov (United States)

    Piper, T; Piper, J

    2012-09-01

    Axial phase-darkfield-contrast (APDC) has been developed as an illumination technique in light microscopy which promises significant improvements and a higher variability in imaging of several transparent 'problem specimens'. With this method, a phase contrast image is optically superimposed on an axial darkfield image so that a partial image based on the principal zeroth order maximum (phase contrast) interferes with an image, which is based on the secondary maxima (axial darkfield). The background brightness and character of the resulting image can be continuously modulated from a phase contrast-dominated to a darkfield-dominated character. In order to achieve this illumination mode, normal objectives for phase contrast have to be fitted with an additional central light stopper needed for axial (central) darkfield illumination. In corresponding condenser light masks, a small perforation has to be added in the centre of the phase contrast providing light annulus. These light modulating elements are properly aligned when the central perforation is congruent with the objective's light stop and the light annulus is conjugate with the phase ring. The breadth of the condenser light annulus and thus the intensity of the phase contrast partial image can be regulated with the aperture diaphragm. Additional contrast effects can be achieved when both illuminating light components are filtered at different colours. In this technique, the axial resolution (depth of field) is significantly enhanced and the specimen's three-dimensional appearance is accentuated with improved clarity as well as fine details at the given resolution limit. Typical artefacts associated with phase contrast and darkfield illumination are reduced in our methods.

  14. Evaluation and study of advanced optical contamination, deposition, measurement, and removal techniques. [including computer programs and ultraviolet reflection analysis

    Science.gov (United States)

    Linford, R. M. F.; Allen, T. H.; Dillow, C. F.

    1975-01-01

    A program is described to design, fabricate and install an experimental work chamber assembly (WCA) to provide a wide range of experimental capability. The WCA incorporates several techniques for studying the kinetics of contaminant films and their effect on optical surfaces. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation. Several supporting studies were conducted to define specific chamber requirements, to determine the sensitivity of the measurement techniques to be incorporated in the chamber, and to establish procedures for handling samples prior to their installation in the chamber. A bibliography and literature survey of contamination-related articles is included.

  15. Growth of Nd{sub 2}TiO{sub 5} single crystal using optical floating zone technique

    Energy Technology Data Exchange (ETDEWEB)

    Murugesan, G.; Kalainathan, S., E-mail: kalainathan@yahoo.com [Centre for Crystal Growth, School of Advanced Sciences, VIT University, Vellore-632014 (India); Nithya, R.; Ravindran, T. R. [Materials Science Group, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India)

    2015-06-24

    Single crystals of Nd{sub 2}TiO{sub 5} were grown using Optical Floating zone technique in oxygen atmosphere by spontaneous nucleation. Powder X-ray diffraction pattern showed that the grown single crystal is of homogeneous composition. Laue diffraction was recorded in both transmission and backscattering geometries to check the crystal quality. Vibrational properties were analyzed using Raman measurements.

  16. Coherent demodulation of microwave signals by using optical heterodyne technique with applications to point to point indoor wireless communications systems

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Juarez, A; Gomez-Colin, M R; Rojas-Hernandez, A G [Universidad de Sonora (Mexico); Zaldivar-Huerta, I E; Aguayo-Rodriguez, G [Instituto Nacional de Astrofisica, Optica y Electronica (Mexico); Rodriguez-Asomoza, J, E-mail: agarcia@cifus.uson.mx [Universidad de las Americas-Puebla (Mexico)

    2011-01-01

    An optical communications system using a couple microstrip antennas for distributing point to point analog TV with coherent demodulation based on optical heterodyne in close vicinity is reported in this paper. In the proposed experimental setup, two optical waves at different wavelengths are mixed and applied to a photodetector. Then a beat signal with a frequency equivalent to the spacing of the two wavelengths is obtained at the output of the photodetector. This signal corresponds to a microwave signal located at 1.25 GHz, which it is used as a microwave carrier in the transmitter and as a local oscillator in the receiver of our optical communication system. The feasibility of this technique is demonstrated transmitting a TV signal of 66-72 MHz.

  17. A streak camera based fiber optic pulsed polarimetry technique for magnetic sensing to sub-mm resolution

    Science.gov (United States)

    Smith, R. J.; Weber, T. E.

    2016-11-01

    The technique of fiber optic pulsed polarimetry, which provides a distributed (local) measurement of the magnetic field along an optical fiber, has been improved to the point where, for the first time, photocathode based optical detection of backscatter is possible with sub-mm spatial resolutions. This has been realized through the writing of an array of deterministic fiber Bragg gratings along the fiber, a so-called backscatter-tailored optical fiber, producing a 34 000-fold increase in backscatter levels over Rayleigh. With such high backscatter levels, high repetition rate lasers are now sufficiently bright to allow near continuous field sensing in both space and time with field resolutions as low as 0.005 T and as high as 170 T over a ˜mm interval given available fiber materials.

  18. Effects of heat treatment on morphological, optical and electrical properties of ITO films by sol-gel technique

    Institute of Scientific and Technical Information of China (English)

    LI Zhi-hua; KE Yu-peng; REN Dong-yan

    2008-01-01

    Indium-tin-oxide(ITO) films were prepared on the quarts glass by sol-gel technique. Effects of different heat treatment temperatures and cooling methods on the morphological, optical and electrical properties of ITO films were measured by TG/DTA, IR, XRD, SEM, UV-VIS spectrometer and four-probe apparatus. It is found that the crystallized ITO films exhibit a polycrystalline cubic bixbyite structure. The heat treatment process has significant effects on the morphological, optical and electrical properties of ITO films. Elevating the heat treatment temperature can perfect the crystallization process of ITO films, therefore the optical and electrical properties of ITO films are improved. But the further increasing of heat treatment temperature results in the increment of ITO films' resistivity. Compared with ITO films elaborated by furnace cooling, those prepared through air cooling have following characteristics as obviously decreased crystalline size, deeply declined porosity, more compact micro-morphology, improved electrical property and slightly decreased optical transmission.

  19. A streak camera based fiber optic pulsed polarimetry technique for magnetic sensing to sub-mm resolution.

    Science.gov (United States)

    Smith, R J; Weber, T E

    2016-11-01

    The technique of fiber optic pulsed polarimetry, which provides a distributed (local) measurement of the magnetic field along an optical fiber, has been improved to the point where, for the first time, photocathode based optical detection of backscatter is possible with sub-mm spatial resolutions. This has been realized through the writing of an array of deterministic fiber Bragg gratings along the fiber, a so-called backscatter-tailored optical fiber, producing a 34 000-fold increase in backscatter levels over Rayleigh. With such high backscatter levels, high repetition rate lasers are now sufficiently bright to allow near continuous field sensing in both space and time with field resolutions as low as 0.005 T and as high as 170 T over a ∼mm interval given available fiber materials.

  20. Coherent demodulation of microwave signals by using optical heterodyne technique with applications to point to point indoor wireless communications systems

    Science.gov (United States)

    García-Juárez, A.; Zaldívar-Huerta, I. E.; Aguayo-Rodríguez, G.; Rodríguez-Asomoza, J.; Gómez-Colín, M. R.; Rojas-Hernández, A. G.

    2011-01-01

    An optical communications system using a couple microstrip antennas for distributing point to point analog TV with coherent demodulation based on optical heterodyne in close vicinity is reported in this paper. In the proposed experimental setup, two optical waves at different wavelengths are mixed and applied to a photodetector. Then a beat signal with a frequency equivalent to the spacing of the two wavelengths is obtained at the output of the photodetector. This signal corresponds to a microwave signal located at 1.25 GHz, which it is used as a microwave carrier in the transmitter and as a local oscillator in the receiver of our optical communication system. The feasibility of this technique is demonstrated transmitting a TV signal of 66-72MHz.

  1. A novel optical coherence tomography-based micro-indentation technique for mechanical characterization of hydrogels.

    Science.gov (United States)

    Yang, Ying; Bagnaninchi, Pierre O; Ahearne, Mark; Wang, Ruikang K; Liu, Kuo-Kang

    2007-12-22

    Depth-sensing micro-indentation has been well recognized as a powerful tool for characterizing mechanical properties of solid materials due to its non-destructive approach. Based on the depth-sensing principle, we have developed a new indentation method combined with a high-resolution imaging technique, optical coherence tomography, which can accurately measure the deformation of hydrogels under a spherical indenter at constant force. The Hertz contact theory has been applied for quantitatively correlating the indentation force and the deformation with the mechanical properties of the materials. Young's moduli of hydrogels estimated by the new method are comparable with those measured by conventional depth-sensing micro-indentation. The advantages of this new method include its capability to characterize mechanical properties of bulk soft materials and amenability to perform creeping tests. More importantly, the measurement can be performed under sterile conditions allowing non-destructive, in situ and real-time investigations on the changes in mechanical properties of soft materials (e.g. hydrogel). This unique character can be applied for various biomechanical investigations such as monitoring reconstruction of engineered tissues.

  2. A new technique of recognition for coded targets in optical 3D measurement

    Science.gov (United States)

    Guo, Changye; Cheng, Xiaosheng; Cui, Haihua; Dai, Ning; Weng, Jinping

    2014-11-01

    A new technique for coded targets recognition in optical 3D-measurement application is proposed in this paper. Traditionally, point cloud registration is based on homologous features, such as the curvature, which is time-consuming and not reliable. For this, we paste some coded targets onto the surface of the object to be measured to improve the optimum target location and accurate correspondence among multi-source images. Circular coded targets are used, and an algorithm to automatically detecting them is proposed. This algorithm extracts targets with intensive bimodal histogram features from complex background, and filters noise according to their size, shape and intensity. In addition, the coded targets' identification is conducted out by their ring codes. We affine them around the circle inversely, set foreground and background respectively as 1 and 0 to constitute a binary number, and finally shift one bit every time to calculate a decimal one of the binary number to determine a minimum decimal number as its code. In this 3Dmeasurement application, we build a mutual relationship between different viewpoints containing three or more coded targets with different codes. Experiments show that it is of efficiency to obtain global surface data of an object to be measured and is robust to the projection angles and noise.

  3. Investigating the vortex melting phenomenon in BSCCO crystals using magneto-optical imaging technique

    Indian Academy of Sciences (India)

    A Soibel; S S Banerjee; Y Myasoedov; M L Rappaport; E Zeldov; S Ooi; T Tamegai

    2002-05-01

    Using a novel differential magneto-optical imaging technique we investigate the phenomenon of vortex lattice melting in crystals of Bi2Sr2CaCu2O8 (BSCCO). The images of melting reveal complex patterns in the formation and evolution of the vortex solid–liquid interface with varying field ()/temperature (). We believe that the complex melting patterns are due to a random distribution of material disorder/inhomogeneities across the sample, which create fluctuations in the local melting temperature or field value. To study the fluctuations in the local melting temperature/field, we have constructed maps of the melting landscape m(, ), viz., the melting temperature (m) at a given location () in the sample at a given field (). A study of these melting landscapes reveals an unexpected feature: the melting landscape is not fixed, but changes rather dramatically with varying field and temperature along the melting line. It is concluded that the changes in both the scale and shape of the landscape result from the competing contributions of different types of quenched disorder which have opposite effects on the local melting transition.

  4. Measurement of stress-strain behaviour of human hair fibres using optical techniques.

    Science.gov (United States)

    Lee, J; Kwon, H J

    2013-06-01

    Many studies have presented stress-strain relationship of human hair, but most of them have been based on an engineering stress-strain curve, which is not a true representation of stress-strain behaviour. In this study, a more accurate 'true' stress-strain curve of human hair was determined by applying optical techniques to the images of the hair deformed under tension. This was achieved by applying digital image cross-correlation (DIC) to 10× magnified images of hair fibres taken under increasing tension to estimate the strain increments. True strain was calculated by summation of the strain increments according to the theoretical definition of 'true' strain. The variation in diameter with the increase in longitudinal elongation was also measured from the 40× magnified images to estimate the Poisson's ratio and true stress. By combining the true strain and the true stress, a true stress-strain curve could be determined, which demonstrated much higher stress values than the conventional engineering stress-strain curve at the same degree of deformation. Four regions were identified in the true stress-strain relationship and empirical constitutive equations were proposed for each region. Theoretical analysis on the necking condition using the constitutive equations provided the insight into the failure mechanism of human hair. This analysis indicated that local thinning caused by necking does not occur in the hair fibres, but, rather, relatively uniform deformation takes place until final failure (fracture) eventually occurs.

  5. Enhancement of security for free space optics based on reconfigurable chaotic technique

    Science.gov (United States)

    Abdulameer, Lwaa F.; Jignesh, Jokhakar D.; Sripati, U.; Kulkarni, Murlidhar

    2013-01-01

    Free Space Optical (FSO) technology offers highly directional, high bandwidth communication channels. This technology can provide fiber-like data rate over short distances. In order to improve security associated with data transmission in FSO networks, a secure communication method based on chaotic technique is presented. In this paper, we have turned our focus on a specific class of piece wise linear one-dimensional chaotic maps. Simulation results indicate that this approach has the advantage of possessing excellent correlation property. In this paper we examine the security vulnerabilities of single FSO links and propose a solution to this problem by implementing the chaotic signal generator "reconfigurable tent map". As synchronization between transmitter and receiver is essential for the correct operation of such schemes, we have also attempted to determine parameters such as auto- and cross-correlation that determine the ease with which synchronization between transmitter and receiver can be achieved. It is demonstrated that cross correlation is very close to zero and auto-correlation is 􀟜-like. The overall system is implemented in the MATLAB Simulink DSP Builder.

  6. Optical techniques for tracking multiple myeloma engraftment, growth, and response to therapy

    Science.gov (United States)

    Runnels, Judith M.; Carlson, Alicia L.; Pitsillides, Costas; Thompson, Brian; Wu, Juwell; Spencer, Joel A.; Kohler, John M. J.; Azab, Abdelkareem; Moreau, Anne-Sophie; Rodig, Scott J.; Kung, Andrew L.; Anderson, Kenneth C.; Ghobrial, Irene M.; Lin, Charles P.

    2011-01-01

    Multiple myeloma (MM), the second most common hematological malignancy, initiates from a single site and spreads via circulation to multiple sites in the bone marrow (BM). Methods to track MM cells both in the BM and circulation would be useful for developing new therapeutic strategies to target MM cell spread. We describe the use of complementary optical techniques to track human MM cells expressing both bioluminescent and fluorescent reporters in a mouse xenograft model. Long-term tumor growth and response to therapy are monitored using bioluminescence imaging (BLI), while numbers of circulating tumor cells are detected by in-vivo flow cytometry. Intravital microscopy is used to detect early seeding of MM cells to the BM, as well as residual cancer cells that remain in the BM after the bulk of the tumor is eradicated following drug treatment. Thus, intravital microscopy provides a powerful, albeit invasive, means to study cellular processes in vivo at the very early stage of the disease process and at the very late stage of therapeutic intervention when the tumor burden is too small to be detected by other imaging methods.

  7. Laser flash photolysis studies of atmospheric free radical chemistry using optical diagnostic techniques

    Science.gov (United States)

    Wine, Paul H.; Nicovich, J. M.; Hynes, Anthony J.; Stickel, Robert E.; Thorn, R. P.; Chin, Mian; Cronkhite, Jeffrey A.; Shackelford, Christie J.; Zhao, Zhizhong; Daykin, Edward P.

    1993-01-01

    Some recent studies carried out in our laboratory are described where laser flash photolytic production of reactant free radicals has been combined with reactant and/or product detection using time-resolved optical techniques to investigate the kinetics and mechanisms of important atmospheric chemical reactions. Discussed are (1) a study of the radical-radical reaction O + BrO yields Br + O2 where two photolysis lasers are employed to prepare the reaction mixture and where the reactants O and BrO are monitored simultaneously using atomic resonance fluorescence to detect O and multipass UV absorption to detect BrO; (2) a study of the reaction of atomic chlorine with dimethylsulfide (CH3SCH3) where atomic resonance fluorescence detection of Cl is employed to elucidate the kinetics and tunable diode laser absorption spectroscopy is employed to investigate the HCl product yield; and (3) a study of the aqueous phase chemistry of Cl2(-) radicals where longpath UV absorption spectroscopy is employed to investigate the kinetics of the Cl2(-) + H2O reaction.

  8. A new technique for ultra-fast physical random number generation using optical chaos

    CERN Document Server

    Elsonbaty, Amr; Obayyaa, Salah S A

    2016-01-01

    In this paper, we numerically demonstrate a new extraction scheme for generating ultra-fast physically random sequence of bits. For this purpose, we utilize a dual-channel optical chaos source with suppressed time delayed (TD) signature in both the intensity and the phase of its two channels. The proposed technique uses M 1-bit analog-to-digital converters (ADCs) to compare the level of the chaotic intensity signal at time t with its levels after incommensurable delay-interval Tm, where m = {1,2,...,M}. The binary output of each 1-bit ADC is then sampled by a positive-edge-triggered D flip-flop. The clock sequence applied to the flip-flops is relatively delayed such that the rising edge of the clock triggering the m flip-flop precedes the rising edge of the clock of a subsequent m+1 flip-flop by a fixed period. The outputs of all flip-flops are then combined by means of a parity-check logic. Numerical simulations are carried out using values of parameters at which TD signature is suppressed for chosen values ...

  9. Performance Analysis of SAC Optical PPM-CDMA System-Based Interference Rejection Technique

    Science.gov (United States)

    Alsowaidi, N.; Eltaif, Tawfig; Mokhtar, M. R.

    2016-03-01

    In this paper, we aim to theoretically analyse optical code division multiple access (OCDMA) system that based on successive interference cancellation (SIC) using pulse position modulation (PPM), considering the interference between the users, imperfection cancellation occurred during the cancellation process and receiver noises. Spectral amplitude coding (SAC) scheme is used to suppress the overlapping between the users and reduce the receiver noises effect. The theoretical analysis of the multiple access interference (MAI)-limited performance of this approach indicates the influence of the size of M-ary PPM on OCDMA system. The OCDMA system performance improves with increasing M-ary PPM. Therefore, it was found that the SIC/SAC-OCDMA system using PPM technique along with modified prime (MPR) codes used as signature sequence code offers significant improvement over the one without cancellation and it can support up to 103 users at the benchmarking value of bit error rate (BER) = 10-9 with prime number p = 11 while the system without cancellation scheme can support only up to 52 users.

  10. Novel Chromatic Technique Based on Optical Absorbance in Characterizing Mineral Hydraulic Oil Degradation

    Directory of Open Access Journals (Sweden)

    C. V. Ossia

    2012-01-01

    Full Text Available A low cost, compact, real-time, and quick measurement optical device based on the absorbance of white light, which comprised of photodiodes in a 3-element color-sensor, feedback diodes, water and temperature sensing element, and so on, was developed and tested in low absorption mineral oil. The device, a deviation from conventional electrical, mechanical, and electrochemical techniques, uses color ratio (CR and total contamination index (TCI parameters based on transmitted light intensity in RGB wavelengths for oil condition monitoring. Test results showed that CR corroborated CIE chromaticity (- Coordinates and increased with oil degradation unlike Saturation and Hue . CR was found to be independent of the particulate contaminants of oil, but dependent on chemical degradation. TCI depended on both chemical degradation and particulate contaminants in oil, being most sensitive in the blue wavelength range and least in the green. Furthermore, results agreed with those of viscometry, total acid number (TAN, and UV-VIS photospectrometry. CR and TCI gave clearer indication of oil degradation than key monitoring parameters like TAN and were found to be effective criteria for characterizing the degradation of hydraulic mineral oils.

  11. Flexible Riser Monitoring Using Hybrid Magnetic/Optical Strain Gage Techniques through RLS Adaptive Filtering

    Directory of Open Access Journals (Sweden)

    Pipa Daniel

    2010-01-01

    Full Text Available Flexible riser is a class of flexible pipes which is used to connect subsea pipelines to floating offshore installations, such as FPSOs (floating production/storage/off-loading unit and SS (semisubmersible platforms, in oil and gas production. Flexible risers are multilayered pipes typically comprising an inner flexible metal carcass surrounded by polymer layers and spiral wound steel ligaments, also referred to as armor wires. Since these armor wires are made of steel, their magnetic properties are sensitive to the stress they are subjected to. By measuring their magnetic properties in a nonintrusive manner, it is possible to compare the stress in the armor wires, thus allowing the identification of damaged ones. However, one encounters several sources of noise when measuring electromagnetic properties contactlessly, such as movement between specimen and probe, and magnetic noise. This paper describes the development of a new technique for automatic monitoring of armor layers of flexible risers. The proposed approach aims to minimize these current uncertainties by combining electromagnetic measurements with optical strain gage data through a recursive least squares (RLSs adaptive filter.

  12. Non-destructive optical clearing technique enhances optical coherence tomography (OCT) for real-time, 3D histomorphometry of brain tissue (Conference Presentation)

    Science.gov (United States)

    Paul, Akshay; Chang, Theodore H.; Chou, Li-Dek; Ramalingam, Tirunelveli S.

    2016-03-01

    Evaluation of neurodegenerative disease often requires examination of brain morphology. Volumetric analysis of brain regions and structures can be used to track developmental changes, progression of disease, and the presence of transgenic phenotypes. Current standards for microscopic investigation of brain morphology are limited to detection of superficial structures at a maximum depth of 300μm. While histological techniques can provide detailed cross-sections of brain structures, they require complicated tissue preparation and the ultimate destruction of the sample. A non-invasive, label-free imaging modality known as Optical Coherence Tomography (OCT) can produce 3-dimensional reconstructions through high-speed, cross-sectional scans of biological tissue. Although OCT allows for the preservation of intact samples, the highly scattering and absorbing properties of biological tissue limit imaging depth to 1-2mm. Optical clearing agents have been utilized to increase imaging depth by index matching and lipid digestion, however, these contemporary techniques are expensive and harsh on tissues, often irreversibly denaturing proteins. Here we present an ideal optical clearing agent that offers ease-of-use and reversibility. Similar to how SeeDB has been effective for microscopy, our fructose-based, reversible optical clearing technique provides improved OCT imaging and functional immunohistochemical mapping of disease. Fructose is a natural, non-toxic sugar with excellent water solubility, capable of increasing tissue transparency and reducing light scattering. We will demonstrate the improved depth-resolving performance of OCT for enhanced whole-brain imaging of normal and diseased murine brains following a fructose clearing treatment. This technique potentially enables rapid, 3-dimensional evaluation of biological tissues at axial and lateral resolutions comparable to histopathology.

  13. A comparative study on the optical limiting properties of different nano spinel ferrites with Z-scan technique

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Jeevan Job; Krishnan, Shiji [School of Pure and Applied Physics, Mahatma Gandhi University, Kottayam, Kerala 686560 (India); Sridharan, K.; Philip, Reji [Light and Matter Physics Group, Raman Research Institute, C.V. Raman Avenue, Sadashivanagar, Bangalore 560080 (India); Kalarikkal, Nandakumar, E-mail: nkkalarikkal@mgu.ac.in [School of Pure and Applied Physics, Mahatma Gandhi University, Kottayam, Kerala 686560 (India); Centre for Nanoscience and Nanotechnology, Mahatma Gandhi University, Kottayam, Kerala 686560 (India)

    2012-08-15

    Highlights: ► First report in which the optical limiting properties of five different nano spinel ferrites are compared. ► The obtained nonlinearity fits to a two-photon like absorption process. ► Except for NiFe{sub 2}O{sub 4}, the observed nonlinearity has contributions from excited state absorption. ► A size dependent optical limiting response is obtained. ► Among the investigated ferrites, ZnFe{sub 2}O{sub 4} is found to be a better candidate for the optical limiting applications. -- Abstract: We report the optical limiting properties of five different spinel ferrites, NiFe{sub 2}O{sub 4}, Ni{sub 0.5}Zn{sub 0.5}Fe{sub 2}O{sub 4}, ZnFe{sub 2}O{sub 4}, Ni{sub 0.5}Co{sub 0.5}Fe{sub 2}O{sub 4}, and CoFe{sub 2}O{sub 4} with an average particle grain size of 8 nm. The optical limiting properties are investigated using the open aperture Z-scan technique. The obtained nonlinearity fits to a two-photon like absorption process. Except for NiFe{sub 2}O{sub 4}, the observed nonlinearity has contributions from excited state absorption. The optical limiting response is also studied against particle size and the nonlinearity is found to increase with increasing particle size within the range of our investigations. On comparing the optical limiting properties, ZnFe{sub 2}O{sub 4} is found to be a better candidate for the optical limiting applications. To the best of our knowledge, this is the first report where the optical limiting properties of spinel ferrites are compared.

  14. Optical fiber cable and wiring techniques for fiber to the home (FTTH)

    Science.gov (United States)

    Takai, Hirofumi; Yamauchi, Osamu

    2009-08-01

    NTT group's new medium-term management strategy calls for 20 million optical subscribers by 2010, and NTT Laboratories is pushing forward to meet this goal. Before that date, an efficient optical access network must be constructed, and afterwards, when the era of mass optical communications finally arrives, the facilities and equipment supporting the network will have to be effectively operated and maintained. At NTT Access Network Service Systems Laboratories, we are developing various technologies to correspond to the massive deployment of optical broadband services. We are also developing various new technologies for efficiently operating optical access network systems that will continue to expand in the future, and to supply our customers with good services. This paper provides an overview of the new optical access network system technologies that are being developed at NTT Access Network Service Systems Laboratories to address these issues.

  15. Optical Super-Resolution Imaging of β-Amyloid Aggregation In Vitro and In Vivo: Method and Techniques.

    Science.gov (United States)

    Pinotsi, Dorothea; Kaminski Schierle, Gabriele S; Kaminski, Clemens F

    2016-01-01

    Super-resolution microscopy has emerged as a powerful and non-invasive tool for the study of molecular processes both in vitro and in live cells. In particular, super-resolution microscopy has proven valuable for research studies in protein aggregation. In this chapter we present details of recent advances in this method and the specific techniques, enabling the study of amyloid beta aggregation optically, both in vitro and in cells. First, we show that variants of optical super-resolution microscopy provide a capability to visualize oligomeric and fibrillar structures directly, providing detailed information on species morphology in vitro and even in situ, in the cellular environment. We focus on direct Stochastic Optical Reconstruction Microscopy, dSTORM, which provides morphological detail on spatial scales below 20 nm, and provide detailed protocols for its implementation in the context of amyloid beta research. Secondly, we present a range of optical techniques that offer super-resolution indirectly, which we call multi-parametric microscopy. The latter offers molecular scale information on self-assembly reactions via changes in protein or fluorophore spectral signatures. These techniques are empowered by our recent discovery that disease related amyloid proteins adopt intrinsic energy states upon fibrilisation. We show that fluorescence lifetime imaging provides a particularly sensitive readout to report on the aggregation state, which is robustly quantifiable for experiments performed either in vitro or in vivo.

  16. Modified Powder-in-Tube Technique Based on the Consolidation Processing of Powder Materials for Fabricating Specialty Optical Fibers

    Directory of Open Access Journals (Sweden)

    Jean-Louis Auguste

    2014-08-01

    Full Text Available The objective of this paper is to demonstrate the interest of a consolidation process associated with the powder-in-tube technique in order to fabricate a long length of specialty optical fibers. This so-called Modified Powder-in-Tube (MPIT process is very flexible and paves the way to multimaterial optical fiber fabrications with different core and cladding glassy materials. Another feature of this technique lies in the sintering of the preform under reducing or oxidizing atmosphere. The fabrication of such optical fibers implies different constraints that we have to deal with, namely chemical species diffusion or mechanical stress due to the mismatches between thermal expansion coefficients and working temperatures of the fiber materials. This paper focuses on preliminary results obtained with a lanthano-aluminosilicate glass used as the core material for the fabrication of all-glass fibers or specialty Photonic Crystal Fibers (PCFs. To complete the panel of original microstructures now available by the MPIT technique, we also present several optical fibers in which metallic particles or microwires are included into a silica-based matrix.

  17. Tracking the eye non-invasively: Simultaneous comparison of the scleral search coil and optical tracking techniques in themacaque monkey

    Directory of Open Access Journals (Sweden)

    Daniel L. Kimmel

    2012-08-01

    Full Text Available From human perception to primate neurophysiology, monitoring eye position is critical to the study of vision, attention, oculomotor control, and behavior. Two principal techniques for the precise measurement of eye position—the long-standing sclera-embedded search coil and more recent optical tracking techniques—are in use in various laboratories, but no published study compares the performance of the two methods simultaneously in the same primates. Here we compare two popular systems—a sclera-embedded search coil from C-N-C Engineering and the EyeLink 1000 optical system from SR Research—by recording simultaneously from the same eye in the macaque monkey while the animal performed a simple oculomotor task. We found broad agreement between the two systems, particularly in positional accuracy during fixation, measurement of saccade amplitude, detection of fixational saccades, and sensitivity to subtle changes in eye position from trial to trial. Nonetheless, certain discrepancies persist, particularly elevated saccade peak velocities, post-saccadic ringing, influence of luminance change on reported position, and greater sample-to-sample variation in the optical system. Our study shows that optical performance now rivals that of the search coil, rendering optical systems appropriate for many if not most applications. This finding is consequential, especially for animal subjects, because the optical systems do not require invasive surgery for implantation and repair of search coils around the eye. Our data also allow laboratories using the optical system in human subjects to assess the strengths and limitations of the technique for their own applications.

  18. Fiber Optic Surface Plasmon Resonance-Based Biosensor Technique: Fabrication, Advancement, and Application.

    Science.gov (United States)

    Liang, Gaoling; Luo, Zewei; Liu, Kunping; Wang, Yimin; Dai, Jianxiong; Duan, Yixiang

    2016-05-03

    Fiber optic-based biosensors with surface plasmon resonance (SPR) technology are advanced label-free optical biosensing methods. They have brought tremendous progress in the sensing of various chemical and biological species. This review summarizes four sensing configurations (prism, grating, waveguide, and fiber optic) with two ways, attenuated total reflection (ATR) and diffraction, to excite the surface plasmons. Meanwhile, the designs of different probes (U-bent, tapered, and other probes) are also described. Finally, four major types of biosensors, immunosensor, DNA biosensor, enzyme biosensor, and living cell biosensor, are discussed in detail for their sensing principles and applications. Future prospects of fiber optic-based SPR sensor technology are discussed.

  19. Using wavefront coding technique as an optical encryption system: reliability analysis and vulnerabilities assessment

    Science.gov (United States)

    Konnik, Mikhail V.

    2012-04-01

    Wavefront coding paradigm can be used not only for compensation of aberrations and depth-of-field improvement but also for an optical encryption. An optical convolution of the image with the PSF occurs when a diffractive optical element (DOE) with a known point spread function (PSF) is placed in the optical path. In this case, an optically encoded image is registered instead of the true image. Decoding of the registered image can be performed using standard digital deconvolution methods. In such class of optical-digital systems, the PSF of the DOE is used as an encryption key. Therefore, a reliability and cryptographic resistance of such an encryption method depends on the size and complexity of the PSF used for optical encoding. This paper gives a preliminary analysis on reliability and possible vulnerabilities of such an encryption method. Experimental results on brute-force attack on the optically encrypted images are presented. Reliability estimation of optical coding based on wavefront coding paradigm is evaluated. An analysis of possible vulnerabilities is provided.

  20. Optical properties of atmospheric particles: complete parameter sets obtained through polar photometry and an improved inversion technique.

    Science.gov (United States)

    Hänel, G

    1994-10-20

    Complete sets of optical parameters of dry particles sampled on a Nuclepore filter are derived through interpretation of photometric data with an improved inversion technique. The parameters are the volume-extinction and absorption coefficients, the single-scattering albedo, the asymmetry parameter of the volume scattering function, the apparent complex refractive index, and the apparent soot content. They may serve as input data for solar radiation-budget considerations. Results from preliminary measurements taken in Central Europe and Italy show an extreme variability of the optical parameters. Both large regional and temporal variabilities have been observed caused by the fluctuating midlatitude weather systems and human activities.

  1. A Novel Noise Free Transmission Technique for Designing 100Gb/s Future Generation Optical Communication System

    DEFF Research Database (Denmark)

    Das, Bhagwan; Abdullah, M.F.L.; Pandey, Bishwajeet

    2017-01-01

    Differential Phase Shift Keying (DPSK) techniques are widely used in designing the high-speed communication systems. However, these techniques still need improvement for long haul communication system design. In this paper, high-speed optical signal transmission and reception system is achieved f...... the transmission and reception of data for high-speed long haul communication system without using any amplifier or repeater.......Differential Phase Shift Keying (DPSK) techniques are widely used in designing the high-speed communication systems. However, these techniques still need improvement for long haul communication system design. In this paper, high-speed optical signal transmission and reception system is achieved...... that BER of 10-12+, Q-factor 98 at power penalty of 14 dB is attained using the designed technique for transmitting 100Gb/s at 300 Km. Whereas, existing NRZ technique achieved a BER of 10-6, Q-factor 32 at power penalty of 11 dB for same similar transmission data rate and distance. The designed offers...

  2. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique

    Directory of Open Access Journals (Sweden)

    Md. Rajibur Rahaman Khan

    2016-11-01

    Full Text Available In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM technique. According to the optical-fiber PWM method, the received sensing signal’s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R2 is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry–Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.

  3. Electro-Optical Sensor Fabricated Using a Bulk Cleavage Technique and Its Characteristics for Near-Field Intra-Body Communication

    Science.gov (United States)

    Furuya, Akinori; Sasaki, Ai-ichiro; Morimura, Hiroki; Aihara, Kimihisa; Shinagawa, Mitsuru

    2013-09-01

    This paper describes how to obtain a low cost electro-optical (EO) sensor module for the mass production of near-field intra-body communication devices. In this study, we used a bulk cleavage technique to fabricate EO modulators without the need for any optical polishing or washing processes, and clarified the feasibility of assembling optical components using only a passive alignment technique with a compact housing.

  4. Investigation of Surface Breakdown on Semiconductor Devices Using Optical Probing Techniques.

    Science.gov (United States)

    1990-01-01

    18] L. Bovino , T. Burke, R. Youmans, M. Weiner, and J. Car, r, "Recent Advances in Optically C’ntrolled Bulk Semiconductor Switches," Digest of...Comp. Simul. 5 (3), 175 (1988). [321 M. Weiner, L. Bovino , R. Youmans, and T. Burke, "Modeling of the Optically Conrolled Semiconductor Switch," J

  5. Integrated optical devices for wavelength division multiplexing using PECVD and direct UV writing techniques

    DEFF Research Database (Denmark)

    Zauner, Dan; Leistiko, Otto

    1999-01-01

    Wavelength division multiplexing (WDM) is the currents tep in the development of optical telecommunication. The emphasis of the project is to explore the exisiting photonic technology to realize integrated optical structures for WDM systems. Two methods of fabricting silica on silicon buried...

  6. Advanced demodulation technique for the extraction of tissue optical properties and structural orientation contrast in the spatial frequency domain

    Science.gov (United States)

    Nadeau, Kyle P.; Durkin, Anthony J.; Tromberg, Bruce J.

    2014-05-01

    We have developed a method for extracting spatial frequency information content from biological tissue, which is used to calculate tissue optical properties and determine tissue structural orientation. This demodulation method employs a two-dimensional Hilbert transform using a spiral phase function in Fourier space. The approach presented here allows for the determination of tissue optical properties using a single frame of data for each modulation frequency, increasing imaging speed by two to threefold versus conventional, three-phase spatial frequency domain imaging (SFDI). This new single-phase Hilbert transform approach recovers optical property and scattering orientation index values within 1% and 10% of three-phase SFDI, respectively. These results suggest that, using the Hilbert demodulation technique, SFDI data acquisition speed can be increased significantly while preserving data quality, which will help us move forward toward the implementation of a real-time SFDI platform.

  7. Surface morphology and optical properties of cdse films obtained by the close-spaced vacuum sublimation technique

    Directory of Open Access Journals (Sweden)

    V.V. Starikov

    2009-01-01

    Full Text Available Investigation of the surface morphology, growth mechanisms and optical properties of CdSe films obtained by the close-spaced vacuum sublimation (CSVS technique, which are promising for use as the absorption layers of tandem solar cells and photodetectors, was carried out in the present paper. Measurements of the optical characteristics of the layers were performed by the spectrophotometric analysis method near the “red boundary” of semiconductor photoactivity. Performed investigations allowed to obtain the spectral distributions of the transmission T(λ, reflection R(λ, absorption α(λ, and refraction n(λ coefficients, and the real ε1(λ and imaginary ε2(λ parts of the optical dielectric constant of the samples and to define their dependence on the film deposition temperature.

  8. Secured optical fiber communication using polarization restoration technique and channel characterization

    Science.gov (United States)

    Punekar, Nikhil; Darunkar, Bhagyashri; Verma, Pramode

    2016-02-01

    Optical fiber channels are used as media to transfer the information globally. This paper presents an implementation of a novel procedure using which a secured communication between two parties can be carried out using polarized beam of light over an optical fiber. The paper presents the experimental results obtained of the procedure in the lab environment and a security analysis of the same. It is observed that polarization state of a light pulse cannot be retained as it travels over an optical fiber because of the birefringence phenomenon. Multiple environmental factors such as pressure, vibration, temperature, etc. also add a non-linearity to the birefringence of an optical fiber leading towards an unpredictable polarization state changes over the course of an optical fiber. The proposed procedure helps the receiving party to successfully retrieve the data in the form of a polarization state transmitted by the sending party without having any knowledge about the state of polarization at the transmitting end. The paper also explains an added layer of security the procedure provides to the communicating parties to make it difficult for an adversary to fetch the data being transferred. The proposed system does not depend on the wavelength of the light being used, nor does it depend upon the type of the optical fiber used for the communication. Using this procedure, multiple bits of secured information can be sent over an optical fiber in a single polarized pulse and retrieved at the receiving end, also known as Polarization Shift Keying.

  9. Brain connectivity study of joint attention using frequency-domain optical imaging technique

    Science.gov (United States)

    Chaudhary, Ujwal; Zhu, Banghe; Godavarty, Anuradha

    2010-02-01

    Autism is a socio-communication brain development disorder. It is marked by degeneration in the ability to respond to joint attention skill task, from as early as 12 to 18 months of age. This trait is used to distinguish autistic from nonautistic populations. In this study, diffuse optical imaging is being used to study brain connectivity for the first time in response to joint attention experience in normal adults. The prefrontal region of the brain was non-invasively imaged using a frequency-domain based optical imager. The imaging studies were performed on 11 normal right-handed adults and optical measurements were acquired in response to joint-attention based video clips. While the intensity-based optical data provides information about the hemodynamic response of the underlying neural process, the time-dependent phase-based optical data has the potential to explicate the directional information on the activation of the brain. Thus brain connectivity studies are performed by computing covariance/correlations between spatial units using this frequency-domain based optical measurements. The preliminary results indicate that the extent of synchrony and directional variation in the pattern of activation varies in the left and right frontal cortex. The results have significant implication for research in neural pathways associated with autism that can be mapped using diffuse optical imaging tools in the future.

  10. Experimental measurement of a time-varying optical path difference by the small-aperture beam technique

    Science.gov (United States)

    Hugo, Ronald J.; Jumper, Eric J.

    1996-08-01

    We discuss the use of time series of the jitter angle of multiple, small-aperture probe beams (the small-aperture beam technique, or SABT) as they emerge from a turbulent, optically active flow-field to quantify the time-varying optical path difference (OPD). The flow field studied is that for the transitionally turbulent region of a two-dimensional heated jet. Techniques to construct a complete time series of instantaneous realizations of the OPD are first applied to a numerically generated flow field and then to an experimental flow field. The SABT sensor's measurement accuracy is assessed, and its application to flow fields that differ from the numerical heated jet is discussed.

  11. Applications of Optical Interferometer Techniques for Precision Measurements of Changes in Temperature, Growth and Refractive Index of Materials

    Directory of Open Access Journals (Sweden)

    Rami Reddy Bommareddi

    2014-05-01

    Full Text Available Optical metrology techniques used to measure changes in thickness; temperature and refractive index are surveyed. Optical heterodyne detection principle and its applications for precision measurements of changes in thickness and temperature are discussed. Theoretical formulations are developed to estimate crystal growth rate, surface roughness and laser cooling/heating of solids. Applications of Michelson and Mach-Zehnder interferometers to measure temperature changes in laser heating of solids are described. A Mach-Zehnder interferometer is used to measure refractive index and concentration variations of solutions in crystal growth experiments. Additionally, fluorescence lifetime sensing and fluorescence ratio method are described for temperature measurement. For all the above techniques, uncertainty calculations are included.

  12. Enhanced performance of 400 Gb/s DML-based CAP systems using optical filtering technique for short reach communication.

    Science.gov (United States)

    Tao, Li; Wang, Yiguang; Xiao, Jiangnan; Chi, Nan

    2014-12-01

    A parallel transmission approach is more likely to realize 400 Gb/s and above short reach transmission as it helps to reduce the cost of both electrical and optical device largely. Directly modulated lasers (DML) are more attractive in 400 Gb/s approach, because it requires relatively small amount of driving power and has low insertion loss, thus lowering its cost. However, the intrinsic chirp will degrade the transmission performance. In this paper, an optical filtering technique is introduced for 400 Gb/s high-speed DML-based carrierless amplitude and phase (CAP) modulation short reach systems for the first time. Owing to the additional optical filter, 1 dB and 3.6 dB sensitivity improvement at BER of 3.8 x 10(-3) is obtained for the back-to-back and 15 km fiber link transmission for single lane at the bitrate of 28 Gb/s. Then a 16-lane CAP16 system with a total bit rate of 413 Gb/s is demonstrated experimentally using low-cost 10 GHz-class DML using optical filtering technique.

  13. Single crystal growth of Sr{sub 2}TiMnO{sub 6} by optical floating zone technique

    Energy Technology Data Exchange (ETDEWEB)

    Murugesan, G.; Kalainathan, S. [Centre for Crystal Growth, School of Advanced Sciences, VIT University, Vellore 632 014, Tamil Nadu (India); Nithya, R. [Materials Science Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102, Tamil Nadu (India); Das, Amitabh [Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai – 400085 (India)

    2016-05-23

    Single crystals of Sr{sub 2}TiMnO{sub 6} were grown by optical floating zone technique. Powder X-ray diffraction studies confirmed the single phase nature of the grown crystal. Laue diffraction studies proved the quality of the grown crystal. Neutron diffraction showed no magnetic ordering down to 6 K. Impedance studies showed temperature dependant relaxation which is due to the presence of oxygen vacancies in the grown crystal.

  14. Hyperspectral imaging-based spatially-resolved technique for accurate measurement of the optical properties of horticultural products

    Science.gov (United States)

    Cen, Haiyan

    Hyperspectral imaging-based spatially-resolved technique is promising for determining the optical properties and quality attributes of horticultural and food products. However, considerable challenges still exist for accurate determination of spectral absorption and scattering properties from intact horticultural products. The objective of this research was, therefore, to develop and optimize hyperspectral imaging-based spatially-resolved technique for accurate measurement of the optical properties of horticultural products. Monte Carlo simulations and experiments for model samples of known optical properties were performed to optimize the inverse algorithm of a single-layer diffusion model and the optical designs, for extracting the absorption (micro a) and reduced scattering (micros') coefficients from spatially-resolved reflectance profiles. The logarithm and integral data transformation and the relative weighting methods were found to greatly improve the parameter estimation accuracy with the relative errors of 10.4%, 10.7%, and 11.4% for micro a, and 6.6%, 7.0%, and 7.1% for micros', respectively. More accurate measurements of optical properties were obtained when the light beam was of Gaussian type with the diameter of less than 1 mm, and the minimum and maximum source-detector distances were 1.5 mm and 10--20 transport mean free paths, respectively. An optical property measuring prototype was built, based on the optimization results, and evaluated for automatic measurement of absorption and reduced scattering coefficients for the wavelengths of 500--1,000 nm. The instrument was used to measure the optical properties, and assess quality/maturity, of 500 'Redstar' peaches and 1039 'Golden Delicious' (GD) and 1040 'Delicious' (RD) apples. A separate study was also conducted on confocal laser scanning and scanning electron microscopic image analysis and compression test of fruit tissue specimens to measure the structural and mechanical properties of 'Golden

  15. Variable weight Khazani-Syed code using hybrid fixed-dynamic technique for optical code division multiple access system

    Science.gov (United States)

    Anas, Siti Barirah Ahmad; Seyedzadeh, Saleh; Mokhtar, Makhfudzah; Sahbudin, Ratna Kalos Zakiah

    2016-10-01

    Future Internet consists of a wide spectrum of applications with different bit rates and quality of service (QoS) requirements. Prioritizing the services is essential to ensure that the delivery of information is at its best. Existing technologies have demonstrated how service differentiation techniques can be implemented in optical networks using data link and network layer operations. However, a physical layer approach can further improve system performance at a prescribed received signal quality by applying control at the bit level. This paper proposes a coding algorithm to support optical domain service differentiation using spectral amplitude coding techniques within an optical code division multiple access (OCDMA) scenario. A particular user or service has a varying weight applied to obtain the desired signal quality. The properties of the new code are compared with other OCDMA codes proposed for service differentiation. In addition, a mathematical model is developed for performance evaluation of the proposed code using two different detection techniques, namely direct decoding and complementary subtraction.

  16. Optical discrimination of benign and malignant oral tissue using Z-scan technique.

    Science.gov (United States)

    Salman, Mohajer; Hossein, Majles Ara Mohammad; Kamran, Kamrava Seyed; Shayan, Maleki

    2016-12-01

    A new optical method to discriminate benign and malignant oral tissue is reported. Twenty four tissue biopsy of patients tumor have been prepared in standard method without coloring process. The CW He-Ne laser beam interrogated the samples in optical setup. Linear absorption of tissues in laser wavelength measured and nonlinear behavior of tissue biopsies has been investigated by Z-scan setup. We used some simple optical instruments to focus on microsize region of biolayer to investigate less number of cells and to take repeatable test. Results show that the malignant samples have more attenuation than benign samples. Furthermore nonlinear refractive index (n2) of malignant biolayers has positive sign and n2 of benign biopsies has negative sign with the 10(-8)(cm(2)/W) order of magnitude. So this optical method may be used to discriminate malignant from benign tissues. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Digital television routing systems: An introduction to integrated optical waveguide techniques and devices

    Science.gov (United States)

    Willson, J. P.

    1985-08-01

    The development of a digital standard for the coding of component video signals has raised the problem of the appropriate technology to be used for the routing and distribution of such signals within a television studio center. Optical fibers offer a numberr of advantages over coaxial cable, such as high bandwidth, low loss, and small size. However, a major problem with optical transmission is that of routing the optical signals. One possible solution is to use integrated optical switches. The application of such devices for fabricating a large (100 x 100) array suitable for an all-digital BBC Television Centre is considered. The conclusion is that there remains a great deal of development to be done before such an array is feasible.

  18. NOVEL FIBER GRATING SENSOR DEMODULATION TECHNIQUE BASED ON OPTICAL WAVELET FILTERING

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The optical wavelet filter is designed. It can filter and choose frequency swiftly. It can realize demodulation of distributed fiber Bragg grating(FBG) measurement system. Its scanning resolution and scanning period depend on wavelet function. Wavelet function is controlled by computer. Compared to conventional scan filter, optical wavelet filtering has some advantages such as simple structure, high scan frequency, high resolution and good linearity. At last, the error of optical wavelet filter scanning procedure is analyzed. Scanning step length refers to the shifting of optical wavelet window's central frequency. It affects system precision directly. If scanning step length is different, the measured signal is different. The methods of reducing step length guarantee scanning periodic time are presented.

  19. Machine Learning Techniques for Optical Performance Monitoring from Directly Detected PDM-QAM Signals

    DEFF Research Database (Denmark)

    Thrane, Jakob; Wass, Jesper; Piels, Molly

    2017-01-01

    Linear signal processing algorithms are effective in dealing with linear transmission channel and linear signal detection, while the nonlinear signal processing algorithms, from the machine learning community, are effective in dealing with nonlinear transmission channel and nonlinear signal...... detection. In this paper, a brief overview of the various machine learning methods and their application in optical communication is presented and discussed. Moreover, supervised machine learning methods, such as neural networks and support vector machine, are experimentally demonstrated for in-band optical...

  20. FABRICATION OF TISSUE-SIMULATIVE PHANTOMS AND CAPILLARIES AND THEIR INVESTIGATION BY OPTICAL COHERENCE TOMOGRAPHY TECHNIQUES

    Directory of Open Access Journals (Sweden)

    A. V. Bykov

    2013-03-01

    Full Text Available Methods of tissue-simulative phantoms and capillaries fabrication from PVC-plastisol and silicone for application as test-objects in optical coherence tomography (OCT and skin and capillary emulation are considered. Comparison characteristics of these materials and recommendations for their application are given. Examples of phantoms visualization by optical coherence tomography method are given. Possibility of information using from B-scans for refractive index evaluation is shown.

  1. Optical Security System Based on the Biometrics Using Holographic Storage Technique with a Simple Data Format

    Institute of Scientific and Technical Information of China (English)

    Jun Won AN

    2006-01-01

    We implement a first practical holographic security system using electrical biometrics that combines optical encryption and digital holographic memory technologies. Optical information for identification includes a picture of face, a name, and a fingerprint, which has been spatially multiplexed by random phase mask used for a decryption key. For decryption in our biometric security system, a bit-error-detection method that compares the digital bit of live fingerprint with of fingerprint information extracted from hologram is used.

  2. Integration of an organic photodetector onto a plastic optical fiber by means of spray coating technique.

    Science.gov (United States)

    Binda, Maddalena; Natali, Dario; Iacchetti, Antonio; Sampietro, Marco

    2013-08-21

    A working prototype of integrated fiber/receiver system for optical data transmission is realized. The prototype is made by directly depositing an organic photodetector onto a plastic optical fiber. For the deposition of the organic layers, spray coating is successfully exploited. Operation over four orders of magnitude range of light intensities as well as photoresponse to pulsed stimulation are demonstrated. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Investigation of a Cross-Correlation Based Optical Strain Measurement Technique for Detecting radial Growth on a Rotating Disk

    Science.gov (United States)

    Clem, Michelle M.; Woike, Mark R.

    2013-01-01

    The Aeronautical Sciences Project under NASA`s Fundamental Aeronautics Program is extremely interested in the development of novel measurement technologies, such as optical surface measurements in the internal parts of a flow path, for in situ health monitoring of gas turbine engines. In situ health monitoring has the potential to detect flaws, i.e. cracks in key components, such as engine turbine disks, before the flaws lead to catastrophic failure. In the present study, a cross-correlation imaging technique is investigated in a proof-of-concept study as a possible optical technique to measure the radial growth and strain field on an already cracked sub-scale turbine engine disk under loaded conditions in the NASA Glenn Research Center`s High Precision Rotordynamics Laboratory. The optical strain measurement technique under investigation offers potential fault detection using an applied high-contrast random speckle pattern and imaging the pattern under unloaded and loaded conditions with a CCD camera. Spinning the cracked disk at high speeds induces an external load, resulting in a radial growth of the disk of approximately 50.0-im in the flawed region and hence, a localized strain field. When imaging the cracked disk under static conditions, the disk will be undistorted; however, during rotation the cracked region will grow radially, thus causing the applied particle pattern to be .shifted`. The resulting particle displacements between the two images will then be measured using the two-dimensional cross-correlation algorithms implemented in standard Particle Image Velocimetry (PIV) software to track the disk growth, which facilitates calculation of the localized strain field. In order to develop and validate this optical strain measurement technique an initial proof-of-concept experiment is carried out in a controlled environment. Using PIV optimization principles and guidelines, three potential speckle patterns, for future use on the rotating disk, are developed

  4. Ghost analysis visualization techniques for complex systems: examples from the NIF Final Optics Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Beer, G K; Hendrix, J L; Rowe, J; Schweyen, J

    1998-06-26

    The stray light or "ghost" analysis of the National Ignition Facility's (NIP) Final Optics Assembly (FOA) has proved to be one of the most complex ghost analyses ever attempted. The NIF FOA consists of a bundle of four beam lines that: 1) provides the vacuum seal to the target chamber, 2) converts 1ω to 3ω light, 3) focuses the light on the target, 4) separates a fraction of the 3ω beam for energy diagnostics, 5) separates the three wavelengths to diffract unwanted 1ω & 2ω light away from the target, 6) provides spatial beam smoothing, and 7) provides a debris barrier between the target chamber and the switchyard mirrors. The three wavelengths of light and seven optical elements with three diffractive optic surfaces generate three million ghosts through 4th order. Approximately 24,000 of these ghosts have peak fluence exceeding 1 J/cm2. The shear number of ghost paths requires a visualization method that allows overlapping ghosts on optics and mechanical components to be summed and then mapped to the optical and mechanical component surfaces in 3D space. This paper addresses the following aspects of the NIF Final Optics Ghost analysis: 1) materials issues for stray light mitigation, 2) limitations of current software tools (especially in modeling diffractive optics), 3) computer resource limitations affecting automated coherent raytracing, 4) folding the stray light analysis into the opto-mechanical design process, 5) analysis and visualization tools from simple hand calculations to specialized stray light analysis computer codes, and 6) attempts at visualizing these ghosts using a CAD model and another using a high end data visualization software approach.

  5. Precise determination of full matrix of piezo-optic coefficients with a four-point bending technique: the example of lithium niobate crystals.

    Science.gov (United States)

    Krupych, Oleg; Savaryn, Viktoriya; Vlokh, Rostyslav

    2014-04-01

    A recently proposed technique representing a combination of digital imaging laser interferometry with a classical four-point bending method is applied to a canonical nonlinear optical crystal, LiNbO₃, to precisely determine a full matrix of its piezo-optic coefficients (POCs). The contribution of a secondary piezo-optic effect to the POCs is investigated experimentally and analyzed theoretically. Based on the POCs thus obtained, a full matrix of strain-optic coefficients (SOCs) is calculated and the appropriate errors are estimated. A comparison of our experimental errors for the POCs and SOCs with the known reference data allows us to claim the present technique as the most precise.

  6. A Technique to Measure Focal Length of a Lens with no Bulk Motion using Tunable Optics and Optical MEMS Technology

    CERN Document Server

    Reza, Syed Azer

    2016-01-01

    This paper presents a motion-free technique for characterizing the focal length of any spherical convex or concave lens. The measurement system uses a Gaussian Beam from a Laser Source (LS), an Electronically Controlled Variable Focus Lens (ECVFL), a Digital Micromirror Device (DMD) and a Photo-Detector (PD). As the proposed method does not involve any motion-stages or other moving components, the focal length is measured without requiring any mechanical motion of bulk components. The method requires measuring the spot size of the Gaussian Beam at the DMD plane for various settings of the ECVFL focal length. These beam spot size measurements, are used to estimate the focal length of a lens sample by employing standard polynomial-fitting techniques. Due to the inherent motion-free nature of the proposed setup, the measurements are fast, repeatable, reliable and ideal for use in industrial lens production, manufacturing of imaging systems and sensitive laboratory experiments. Using a DMD and an ECVFL also allow...

  7. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  8. The Optical Biopsy: A Novel Technique for Rapid Intraoperative Diagnosis of Primary Pulmonary Adenocarcinomas.

    Science.gov (United States)

    Kennedy, Gregory T; Okusanya, Olugbenga T; Keating, Jane J; Heitjan, Daniel F; Deshpande, Charuhas; Litzky, Leslie A; Albelda, Steven M; Drebin, Jeffrey A; Nie, Shuming; Low, Philip S; Singhal, Sunil

    2015-10-01

    With increasing use of chest computed tomography scans, indeterminate pulmonary nodules are frequently detected as an incidental finding and present a diagnostic challenge. Tissue biopsy followed by histological review and immunohistochemistry is the gold standard to obtain a diagnosis and the most common malignant finding is a primary lung adenocarcinoma. Our objective was to determine whether an intraoperative optical biopsy (molecular imaging) may provide an alternative approach for determining if a pulmonary nodule is a primary lung adenocarcinoma. Before surgery, 30 patients with an indeterminate pulmonary nodule were intravenously administered a folate receptor-targeted fluorescent contrast agent specific for primary lung adenocarcinomas. During surgery, the nodule was removed and the presence of fluorescence (optical biopsy) was assessed in the operating room to determine if the nodule was a primary pulmonary adenocarcinoma. Standard-of-care frozen section and immunohistochemical staining on permanent sections were then performed as the gold standard to validate the results of the optical biopsy. Optical biopsies identified 19 of 19 (100%) primary pulmonary adenocarcinomas. There were no false positive or false negative diagnoses. An optical biopsy required 2.4 minutes compared to 26.5 minutes for frozen section (P biopsy has excellent positive predictive value for intraoperative diagnosis of primary lung adenocarcinomas. With refinement, this technology may prove to be an important supplement to standard pathology for examining close surgical margins, identifying lymph node involvement, and determining whether suspicious nodules are malignant.

  9. Novel electro-optical coupling technique for magnetic resonance-compatible positron emission tomography detectors.

    Science.gov (United States)

    Olcott, Peter D; Peng, Hao; Levin, Craig S

    2009-01-01

    A new magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL) diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  10. Novel Electro-Optical Coupling Technique for Magnetic Resonance-Compatible Positron Emission Tomography Detectors

    Directory of Open Access Journals (Sweden)

    Peter D. Olcott

    2009-03-01

    Full Text Available A new magnetic resonance imaging (MRI-compatible positron emission tomography (PET detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  11. New optical sensing technique of tissue viability and blood flow based on nanophotonic iterative multi-plane reflectance measurements

    Directory of Open Access Journals (Sweden)

    Yariv I

    2016-10-01

    Full Text Available Inbar Yariv,1 Menashe Haddad,2,3 Hamootal Duadi,1 Menachem Motiei,1 Dror Fixler1 1Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel; 2Sackler School of Medicine, Tel-Aviv University, Tel-Aviv, Israel; 3Mayanei Hayeshua Medical Center, Benei Brak, Israel Abstract: Physiological substances pose a challenge for researchers since their optical properties change constantly according to their physiological state. Examination of those substances noninvasively can be achieved by different optical methods with high sensitivity. Our research suggests the application of a novel noninvasive nanophotonics technique, ie, iterative multi-plane optical property extraction (IMOPE based on reflectance measurements, for tissue viability examination and gold nanorods (GNRs and blood flow detection. The IMOPE model combines an experimental setup designed for recording light intensity images with the multi-plane iterative Gerchberg-Saxton algorithm for reconstructing the reemitted light phase and calculating its standard deviation (STD. Changes in tissue composition affect its optical properties which results in changes in the light phase that can be measured by its STD. We have demonstrated this new concept of correlating the light phase STD and the optical properties of a substance, using transmission measurements only. This paper presents, for the first time, reflectance based IMOPE tissue viability examination, producing a decrease in the computed STD for older tissues, as well as investigating their organic material absorption capability. Finally, differentiation of the femoral vein from adjacent tissues using GNRs and the detection of their presence within blood circulation and tissues are also presented with high sensitivity (better than computed tomography to low quantities of GNRs (<3 mg. Keywords: Gerchberg-Saxton, optical properties, gold nanorods, blood vessel, tissue viability

  12. Relative humidity multi-point optical sensors system based on fast Fourier multiplexing technique

    Science.gov (United States)

    Lopez-Aldaba, A.; Lopez-Torres, D.; Elosua, C.; Auguste, J.-L.; Jamier, R.; Roy, P.; Arregui, F. J.; Lopez-Amo, M.

    2017-04-01

    In this paper, a new multipoint optical fiber system for relative humidity measurements based on SnO2-FP (Fabry-Pérot) sensing heads and an optical interrogator as single active device is presented and characterized. The interrogation of the sensing heads is carried out by monitoring the Fast Fourier Transform phase variations of the FP (Fabry-Pérot) interference frequencies. This method allows to multiplex several sensors with different wavelength spacing interference pattern. The sensors operate within a wide humidity range (20%-90% relative humidity) with low crosstalk between them. Five sensing heads have been measured using two different channels of the optical interrogator. The availability of four channels in the interrogator allows to multiplex a higher number of sensors, reducing proportionally the cost of each sensing point.

  13. Study of optical techniques for the Ames unitary wind tunnels. Part 3: Angle of attack

    Science.gov (United States)

    Lee, George

    1992-01-01

    A review of optical sensors that are capable of accurate angle of attack measurements in wind tunnels was conducted. These include sensors being used or being developed at NASA Ames and Langley Research Centers, Boeing Airplane Company, McDonald Aircraft Company, Arnold Engineering Development Center, National Aerospace Laboratory of the Netherlands, National Research Council of Canada, and the Royal Aircraft Establishment of England. Some commercial sensors that may be applicable to accurate angle measurements were also reviewed. It was found that the optical sensor systems were based on interferometers, polarized light detector, linear or area photodiode cameras, position sensing photodetectors, and laser scanners. Several of the optical sensors can meet the requirements of the Ames Unitary Plan Wind Tunnel. Two of these, the Boeing interferometer and the Complere lateral effect photodiode sensors are being developed for the Ames Unitary Plan Wind Tunnel.

  14. Applicability of quantitative optical imaging techniques for intraoperative perfusion diagnostics: a comparison of laser speckle contrast imaging, sidestream dark-field microscopy, and optical coherence tomography.

    Science.gov (United States)

    Jansen, Sanne M; de Bruin, Daniel M; Faber, Dirk J; Dobbe, Iwan J G G; Heeg, Erik; Milstein, Dan M J; Strackee, Simon D; van Leeuwen, Ton G

    2017-08-01

    Patient morbidity and mortality due to hemodynamic complications are a major problem in surgery. Optical techniques can image blood flow in real-time and high-resolution, thereby enabling perfusion monitoring intraoperatively. We tested the feasibility and validity of laser speckle contrast imaging (LSCI), optical coherence tomography (OCT), and sidestream dark-field microscopy (SDF) for perfusion diagnostics in a phantom model using whole blood. Microvessels with diameters of 50, 100, and 400  μm were constructed in a scattering phantom. Perfusion was simulated by pumping heparinized human whole blood at five velocities (0 to 20  mm/s). Vessel diameter and blood flow velocity were assessed with LSCI, OCT, and SDF. Quantification of vessel diameter was feasible with OCT and SDF. LSCI could only visualize the 400-μm vessel, perfusion units scaled nonlinearly with blood velocity. OCT could assess blood flow velocity in terms of inverse OCT speckle decorrelation time. SDF was not feasible to measure blood flow; however, for diluted blood the measurements were linear with the input velocity up to 1  mm/s. LSCI, OCT, and SDF were feasible to visualize blood flow. Validated blood flow velocity measurements intraoperatively in the desired parameter (mL·min-1·g-1) remain challenging. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  15. Observational and laboratory studies of optical properties of black and brown carbon particles in the atmosphere using spectroscopic techniques

    Science.gov (United States)

    Nakayama, Tomoki; Matsumi, Yutaka

    2015-04-01

    Light absorption and scattering by aerosols are as an important contributor to radiation balance in the atmosphere. Black carbon (BC) is considered to be the most potent light absorbing material in the visible region of the spectrum, although light absorbing organic carbon (brown carbon or BrC) and mineral dust may also act as sources of significant absorption, especially in the ultraviolet (UV) and shorter visible wavelength regions. The optical properties of such particles depend on wavelength, particle size and shape, morphology, coating, and complex refractive index (or chemical composition), and therefore accurate in situ measurements of the wavelength dependence of the optical properties of particles are needed. Recently, cavity ring-down spectroscopy (CRDS) and photoacoustic spectroscopy (PAS) have been used for the direct measurements of extinction and absorption coefficients of particles suspended in air. We have applied these techniques to the observational studies of optical properties of BC and BrC in an urban site in Japan and to the laboratory studies of optical properties of secondary organic aerosols (SOAs) generated from a variety of biogenic and anthropogenic volatile organic compounds and those of diesel exhaust particles (DEPs). In the presentation, the basic principles of these techniques and the results obtained in our studies and in the recent literatures will be overviewed. References Guo, X. et al., Measurement of the light absorbing properties of diesel exhaust particles using a three-wavelength photoacoustic spectrometer, Atmos. Environ., 94, 428-437 (2014). Nakayama, T. et al., Measurements of aerosol optical properties in central Tokyo during summertime using cavity ring-down spectroscopy: Comparison with conventional techniques, Atmos. Environ., 44, 3034-3042 (2010). Nakayama, T. et al., Laboratory studies on optical properties of secondary organic aerosols generated during the photooxidation of toluene and the ozonolysis of alpha

  16. Observation of cold Rb{sub 2} molecules trapped in an optical dipole trap using a laser-pulse-train technique

    Energy Technology Data Exchange (ETDEWEB)

    Menegatti, Carlos R.; Marangoni, Bruno S.; Marcassa, Luis G. [Instituto de Fisica de Sao Carlos, Universidade de Sao Paulo, Caixa Postal 369, 13560-970, Sao Carlos, SP (Brazil)

    2011-11-15

    In this work, we have developed and characterized a laser-pulse-train technique to observe cold Rb{sub 2} molecules trapped in an optical dipole trap. The molecules are produced in a magneto-optical trap, and then loaded into a crossed optical dipole trap. The time evolution of the molecular population is obtained by applying a laser pulse train, which photoionizes the ground-state molecules through intermediate molecular bands. Our results show that this technique allows us to obtain a faster data acquisition rate of the time evolution of the molecule population than other techniques.

  17. Development and Ground-Test Validation of Fiber Optic Sensor Attachment Techniques for Hot Structures Applications

    Science.gov (United States)

    Piazza, Anthony; Hudson, Larry D.; Richards, W. Lance

    2005-01-01

    Fiber Optic Strain Measurements: a) Successfully attached silica fiber optic sensors to both metallics and composites; b) Accomplished valid EFPI strain measurements to 1850 F; c) Successfully attached EFPI sensors to large scale hot-structures; and d) Attached and thermally validated FBG bond and epsilon(sub app). Future Development a) Improve characterization of sensors on C-C and C-SiC substrates; b) Apply application to other composites such as SiC-SiC; c) Assist development of interferometer based Sapphire sensor currently being conducted under a Phase II SBIR; and d) Complete combined thermal/mechanical testing of FBG on composite substrates in controlled laboratory environment.

  18. Some aspects of using new techniques of teaching/learning in education in optics (Abstract only)

    Science.gov (United States)

    Suchanska, Malgorzata

    2003-11-01

    The deep learning in Optics can be encouraged by stimulating and considerate teaching. It means that teacher should demonstrate his/her personal commitment to the subject and stress its meaning, relevance and importance to the students. It is also important to allow students to be creative in solving problems and in interpretation of its contents. In order to help the students to become more creative persons it is necessary to enhance the learning process of modern knowledge in Optics, to design and conduct experiments, stimulate passions and interests, allow an access to the e-learning system (Internet) and introduce the psychological training (creativity, communication, lateral thinking etc.) (Abstract only available)

  19. Alignment signal extraction of the optically degenerate RSE interferometer using the wave front sensing technique

    Science.gov (United States)

    Sato, S.; Kawamura, S.

    2008-07-01

    The alignment sensing and control scheme of the resonant sideband extraction interferometer is still an unsettled issue for the next-generation gravitational wave antennas. The issue is that it is difficult to extract separate error signals for all 12 angular degrees of freedom, which is mainly arising from the complexity of the optical system and cavity 'degeneracy'. We have suggested a new sensing scheme giving reasonably separated signals which is fully compatible with the length sensing scheme. The key of this idea is to resolve the 'degeneracy' of the optical cavities. By choosing an appropriate Gouy phase for the degenerate cavities, alignment error signals with much less admixtures can be extracted.

  20. Application of Optical Imaging Techniques for Quantification of pH and O2 Dynamicsin Porous Media

    Science.gov (United States)

    Li, B.; Seliman, A. F.; Pales, A. R.; Liang, W.; Sams, A.; Darnault, C. J. G.; DeVol, T. A.

    2016-12-01

    Understanding the spatial and temporal distribution of physical and chemical parameters (e.g. pH, O2) is imperative to characterize the behavior of contaminants in a natural environment. The objectives of this research are to calibrate pH and O2 sensor foils, to develop a dual pH/O2 sensor foil, and to apply them into flow and transport experiments, in order to understand the physical and chemical parameters that control contaminant fate and transport in an unsaturated sandy porous medium. In addition, demonstration of a sensor foil that quantifies aqueous uranium concentration will be presented. Optical imaging techniques will be conducted with 2D tanks to investigate the influence of microbial exudates and plant roots on pH and O2 parameters and radionuclides transport. As a non-invasive method, the optical imaging technique utilizes optical chemical sensor films and either a digital camera or a spectrometer to capture the changes with high temporal and spatial resolutions. Sensor foils are made for different parameters by applying dyes to generate favorable fluorescence that is proportional to the parameter of interest. Preliminary results suggested that this method could detect pH ranging from 4.5 to 7.5. The result from uranium foil test with different concentrations in the range of 2 to 8 ppm indicated that a higher concentration of uranium resulted in a greater color intensity.

  1. Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique

    Science.gov (United States)

    Simpson, C. Rebecca; Kohl, Matthias; Essenpreis, Matthias; Cope, Mark

    1998-09-01

    The absorption and transport scattering coefficients of caucasian and negroid dermis, subdermal fat and muscle have been measured for all wavelengths between 620 and 1000 nm. Samples of tissue 2 mm thick were measured ex vivo to determine their reflectance and transmittance. A Monte Carlo model of the measurement system and light transport in tissue was then used to recover the optical coefficients. The sample reflectance and transmittance were measured using a single integrating sphere `comparison' method. This has the advantage over conventional double-sphere techniques in that no corrections are required for sphere properties, and so measurements sufficiently accurate to recover the absorption coefficient reliably could be made. The optical properties of caucasian dermis were found to be approximately twice those of the underlying fat layer. At 633 nm, the mean optical properties over 12 samples were and for absorption coefficient and and for transport scattering coefficient for caucasian dermis and the underlying fat layer respectively. The transport scattering coefficient for all biological samples showed a monotonic decrease with increasing wavelength. The method was calibrated using solid tissue phantoms and by comparison with a temporally resolved technique.

  2. A Pulsed Coding Technique Based on Optical UWB Modulation for High Data Rate Low Power Wireless Implantable Biotelemetry

    Directory of Open Access Journals (Sweden)

    Andrea De Marcellis

    2016-10-01

    Full Text Available This paper reports on a pulsed coding technique based on optical Ultra-wideband (UWB modulation for wireless implantable biotelemetry systems allowing for high data rate link whilst enabling significant power reduction compared to the state-of-the-art. This optical data coding approach is suitable for emerging biomedical applications like transcutaneous neural wireless communication systems. The overall architecture implementing this optical modulation technique employs sub-nanosecond pulsed laser as the data transmitter and small sensitive area photodiode as the data receiver. Moreover, it includes coding and decoding digital systems, biasing and driving analogue circuits for laser pulse generation and photodiode signal conditioning. The complete system has been implemented on Field-Programmable Gate Array (FPGA and prototype Printed Circuit Board (PCB with discrete off-the-shelf components. By inserting a diffuser between the transmitter and the receiver to emulate skin/tissue, the system is capable to achieve a 128 Mbps data rate with a bit error rate less than 10−9 and an estimated total power consumption of about 5 mW corresponding to a power efficiency of 35.9 pJ/bit. These results could allow, for example, the transmission of an 800-channel neural recording interface sampled at 16 kHz with 10-bit resolution.

  3. Optical characterization of bubbly flows with a near-critical-angle scattering technique

    Energy Technology Data Exchange (ETDEWEB)

    Onofri, Fabrice R.A.; Krzysiek, Mariusz [IUSTI, UMR, CNRS, University of Provence, Polytech' DME, Technopole Chateau-Gombert, Marseille (France); Mroczka, Janusz [CEPM, Technical University of Wroclaw, Wroclaw (Poland); Ren, Kuan-Fang [CORIA, UMR, CNRS, University of Rouen, Saint-Etienne-du-Rouvray (France); Radev, Stefan [IMECH, Bulgarian Academy of Sciences, Sofia (Bulgaria); Bonnet, Jean-Philippe [M2P2, UMR, CNRS, University Paul Cezanne, Aix-en-Provence (France)

    2009-10-15

    The newly developed critical angle refractometry and sizing technique (CARS) allows simultaneous and instantaneous characterization of the local size distribution and the relative refractive index (i.e. composition) of a cloud of bubbles. The paper presents the recent improvement of this technique by comparison of different light scattering models and inversion procedures. Experimental results carried in various air/water and air/water-ethanol bubbly flows clearly demonstrate the efficiency and the potential of this technique. (orig.)

  4. A new detection technique of gas concentration with optical spectrum absorption at near-IR wavelength

    Institute of Scientific and Technical Information of China (English)

    井文才; 周之砚; 宋霄; 吴頔; 贾大功; 张红霞; 张以谟

    2009-01-01

    Wavelength modulation technique(WMT) and active intracavity technique(ACIT) are first introduced in this paper,which are used to realize the concentration detection of methane and acetylene respectively.When ACIT is combined with wavelength sweep technique(WST),the detection sensitivity of acetylene can be enhanced sharply.When ACIT is combined with WST and WMT,the detection sensitivity of acetylene can be enhanced further.

  5. An optical sensor for hydrogen sulfide detection in open path using WMS-2 f/1 f technique

    Science.gov (United States)

    Song, Li-mei; Liu, Li-wen; Yang, Yan-gang; Guo, Qing-hua; Xi, Jiang-tao

    2016-11-01

    An optical hydrogen sulfide (H2S) sensor based on wavelength modulation spectroscopy with the second harmonic (2 f) corrected by the first harmonic (1 f) signal (WMS-2 f/1 f) is developed using a distributed feedback (DFB) laser emitting at 1.578 μm and a homemade gas cell with 1-m-long optical path length. The novel sensor is constructed by an electrical cabinet and an optical reflecting and receiving end. The DFB laser is employed for targeting a strong H2S line at 6 336.62 cm-1 in the fundamental absorption band of H2S. The sensor performance, including the minimum detection limit and the stability, can be improved by reducing the laser intensity drift and common mode noise by means of the WMS-2 f/1 f technique. The experimental results indicate that the linearity and response time of the sensor are 0.999 26 and 6 s (in concentration range of 15.2—45.6 mg/m3), respectively. The maximum relative deviation for continuous detection (60 min) of 30.4 mg/m3 H2S is 0.48% and the minimum detection limit obtained by Allan variance is 79 μg/m3 with optimal integration time of 32 s. The optical H2S sensor can be applied to environmental monitoring and industrial production, and it has significance for real-time online detection in many fields.

  6. All optical up-converted signal generation with high dispersion tolerance using frequency quadrupling technique for radio over fiber system

    Science.gov (United States)

    Gu, Yiying; Zhao, Jiayi; Hu, Jingjing; Kang, Zijian; Zhu, Wenwu; Fan, Feng; Han, Xiuyou; Zhao, Mingshan

    2016-05-01

    A novel all optical up-converted signal generation scheme with optical single-sideband (OSSB) technique for radio over fiber (RoF) application is presented and experimentally demonstrated using low-bandwidth devices. The OSSB signal is generated by one low-bandwidth intensity LiNbO3 Mach-Zehnder modulator (LN-MZM) under frequency quadrupling modulation scheme and one low-bandwidth LN-MZM under double sideband carrier suppressed modulation (DSB-CS) scheme. The proposed all OSSB generation scheme is capable of high tolerance of fiber chromatic dispersion induced power fading (DIPF) effect. Benefiting from this novel OSSB generation scheme, a 26 GHz radio frequency (RF) signal up-conversion is realized successfully when one sideband of the optical LO signal is reused as the optical carrier for intermediate frequency (IF) signal modulation. The received vector signal transmission over long distance single-mode fiber (SMF) shows negligible DIPF effect with the error vector magnitude (EVM) of 15.7% rms. In addition, a spurious free dynamic range (SFDR) of the OSSB up-converting system is measured up to 81 dB Hz2/3. The experiment results indicate that the proposed system may find potential applications in future wireless communication networks, especially in microcellular personal communication system (MPCS).

  7. Assessment of red blood cell deformability in type 2 diabetes mellitus and diabetic retinopathy by dual optical tweezers stretching technique.

    Science.gov (United States)

    Agrawal, Rupesh; Smart, Thomas; Nobre-Cardoso, João; Richards, Christopher; Bhatnagar, Rhythm; Tufail, Adnan; Shima, David; Jones, Phil H; Pavesio, Carlos

    2016-03-15

    A pilot cross sectional study was conducted to investigate the role of red blood cells (RBC) deformability in type 2 diabetes mellitus (T2DM) without and with diabetic retinopathy (DR) using a dual optical tweezers stretching technique. A dual optical tweezers was made by splitting and recombining a single Nd:YAG laser beam. RBCs were trapped directly (i.e., without microbead handles) in the dual optical tweezers where they were observed to adopt a "side-on" orientation. RBC initial and final lengths after stretching were measured by digital video microscopy, and a Deformability index (DI) calculated. Blood from 8 healthy controls, 5 T2DM and 7 DR patients with respective mean age of 52.4 yrs, 51.6 yrs and 52 yrs was analysed. Initial average length of RBCs for control group was 8.45 ± 0.25 μm, 8.68 ± 0.49 μm for DM RBCs and 8.82 ± 0.32 μm for DR RBCs (p optical tweezers method can hence be reliably used to assess RBC deformability.

  8. Growth and characterization of butyl 4-hydroxybenzoate single crystal by vertical Bridgman technique for third order nonlinear optical applications

    Science.gov (United States)

    Arivazhagan, T.; Siva Bala Solanki, S.; Rajesh, Narayana Perumal

    2017-02-01

    The butyl 4-hydroxybenzoate single crystal has been grown by vertical Bridgman technique using single wall ampoule. The cell parameters of the grown crystal are verified by single crystal X-ray diffraction analysis. The functional groups of the grown crystal were identified by Fourier transform infrared analysis. The melting, decomposition and crystallization point of the compound are determined by thermo gravimetric analysis and differential scanning calorimetric analysis. The mechanical properties of the grown crystal has been analyzed by Vickers microhardness method. The optical behavior of the grown crystal has been observed by UV-vis-NIR transmission spectroscopic analysis which shows that the lower cut-off wavelength lying at 293 nm and found that the energy band gap value is 4.05 eV. The blue light emission of the crystal was identified by photoluminescence studies. The positive third order nonlinear optical parameters like nonlinear refractive index (n2), nonlinear absorption co-efficient (β) and third order nonlinear susceptibility (χ3) of the grown crystal was calculated by Z-scan studies. The positive sign of nonlinear refractive index (n2) indicates that the crystal exhibits self focusing optical nonlinearity. The crystal exhibits good optical power limiting behavior.

  9. Principles for new optical techniques in medical diagnostics for mHealth applications

    Science.gov (United States)

    Balsam, Joshua Michael

    Medical diagnostics is a critical element of effective medical treatment. However, many modern and emerging diagnostic technologies are not affordable or compatible with the needs and conditions found in low-income and middle-income countries and regions. Resource-poor areas require low-cost, robust, easy-to-use, and portable diagnostics devices compatible with telemedicine (i.e. mHealth) that can be adapted to meet diverse medical needs. Many suitable devices will need to be based on optical technologies, which are used for many types of biological analyses. This dissertation describes the fabrication and detection principles for several low-cost optical technologies for mHealth applications including: (1) a webcam based multi-wavelength fluorescence plate reader, (2) a lens-free optical detector used for the detection of Botulinum A neurotoxin activity, (3) a low cost micro-array reader that allows the performance of typical fluorescence based assays demonstrated for the detection of the toxin staphylococcal enterotoxin (SEB), and (4) a wide-field flow cytometer for high throughput detection of fluorescently labeled rare cells. This dissertation discusses how these technologies can be harnessed using readily available consumer electronics components such as webcams, cell phones, CCD cameras, LEDs, and laser diodes. There are challenges in developing devices with sufficient sensitivity and specificity, and approaches are presented to overcoming these challenges to create optical detectors that can serve as low cost medical diagnostics in resource-poor settings for mHealth.

  10. Developments in optically stimulated luminescence techniques for dating and retrospective dosimetry

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Murray, A.S.

    1999-01-01

    Optically stimulated luminescence signals from natural quartz and feldspar are now used routinely in dating geological and archaeological materials. More recently they have also been employed in accident dosimetry, i.e. the retrospective assessment of doses received as a result of a nuclear accid...

  11. Single-intensity-recording optical encryption technique based on phase retrieval algorithm and QR code

    Science.gov (United States)

    Wang, Zhi-peng; Zhang, Shuai; Liu, Hong-zhao; Qin, Yi

    2014-12-01

    Based on phase retrieval algorithm and QR code, a new optical encryption technology that only needs to record one intensity distribution is proposed. In this encryption process, firstly, the QR code is generated from the information to be encrypted; and then the generated QR code is placed in the input plane of 4-f system to have a double random phase encryption. For only one intensity distribution in the output plane is recorded as the ciphertext, the encryption process is greatly simplified. In the decryption process, the corresponding QR code is retrieved using phase retrieval algorithm. A priori information about QR code is used as support constraint in the input plane, which helps solve the stagnation problem. The original information can be recovered without distortion by scanning the QR code. The encryption process can be implemented either optically or digitally, and the decryption process uses digital method. In addition, the security of the proposed optical encryption technology is analyzed. Theoretical analysis and computer simulations show that this optical encryption system is invulnerable to various attacks, and suitable for harsh transmission conditions.

  12. Performance analysis of passive optical network systems based on the IM/DD OFDM modulation technique

    Science.gov (United States)

    Wchir, Besma; Ben Abdallah, Abderrazek; Mhatli, Sofien; Jarajreh, Mutsam; Yang, Sigang; Attia, Rabah

    2016-11-01

    Motivated by the robust immunity to interference as well as the higher spectrum efficiency, Orthogonal Frequency Division Multiplexing (OFDM) has been widely considered as one of the strongest contenders for high-speed Next- Generation Passive Optical Networks (NG-PONs), which satisfies the huge surge in demand for high-speed broadband services. In the other hand, OFDM systems suffer from a high Peak-to-Average Power Ratio (PAPR) at the transmitted signal resulting in signal degradation. The simplest method to deal with the PAPR problem consists in applying deliberate clipping to the transmitted signal which significantly reduces the requirement of the received optical power. In this paper, an analytical evaluation for the performance of an IM/DD optical OFDM system is shown, this is while accounting for clipping distortion and quantification noise caused by the limited bit resolution of DAC converter. Moreover, the paper demonstrates that applying digital signal restoration at the system receiver enables further improvements in the system performances in terms of enhanced effective Signal-to-Noise Ratio (SNR) and reduced optical power that is required to achieve specified Bit-Error-Rate (BER).

  13. 无源光网络(PON)光层监测技术%PON optical layer monitoring techniques

    Institute of Scientific and Technical Information of China (English)

    傅珂; 钱渊; 张锐

    2012-01-01

    This paper discussed PON networks optical layer test using OTDR-based methods, analyse their shortcomings, unavailable characters and modified OTDR-based techniques. For above concerns, reseached the Non-OTDR based monitor approaches, focus on Brillouin frequency shifted and optical coded reflectome-tre methods, reviewed their technical chracters and application prospectives.%讨论了基于OTDR的PON网络测试,分析其局限和改进技术.针对OTDR-based技术的缺陷,研究了非OTDR监测技术,重点是布里渊频率移位和基于光编码的反射测试等,讨论了相关技术的特点和应用前景.

  14. Optical characterization of polyethylene and cobalt phthalocyanine ultrathin films by means of the ATR technique at surface plasmon resonance

    Science.gov (United States)

    Rodríguez Juárez, M.; Muñoz Aguirre, N.; Martínez Pérez, L.; Garibay-Febles, V.; Lozada-Cassou, M.; Becerril, M.; Zelaya Angel, O.

    2006-08-01

    It is well known that the development and determination of optical properties of ultrathin films is an important issue in many technological areas. In this work organic polyethylene (PE) and cobalt phthalocyanines (CoPc) ultrathin films were deposited over metal films using the r.f. sputtering and thermal evaporation techniques, respectively. Attenuated total reflection (ATR) measurements for the system organic film/metal at the surface plasmon resonance (SPR) were used for determining the thicknesses and optical properties of the PE and CoPc thin films. Thicknesses of the order of some nanometers were found, fitting the theoretical multilayer ATR model, for p polarization monochromatic light, to the experimental reflection data. The dielectric function of CoPc ultrathin films was determined at a wavelength of 632.8 nm.

  15. Imaging of the magnetic field structure in megagauss plasmas by combining pulsed polarimetry with an optical Kerr effect shutter technique.

    Science.gov (United States)

    Smith, R J

    2010-10-01

    Pulsed polarimetry in combination with a high speed photographic technique based on the optical Kerr effect is described. The backscatter in a pulsed polarimeter is directed through a scattering cell and photographed using an ∼1 ps shutter, essentially freezing the intensity pattern. The image provides both the local electron density and magnetic field distributions along and transverse to the laser sightline. Submillimeter spatial resolution is possible for probing wavelengths in the visible due to the high densities and strong optical activity. Pulsed polarimetry is thereby extended to centimeter-sized plasmas with n(e)>10(19)-10(20) cm(-3) and B>20-100 T (MG) produced by multiterawatt, multimega-ampere electrical drivers, wire Z pinches, and liner imploded magnetized plasmas.

  16. Spin wave study and optical properties in Fe-doped ZnO thin films prepared by spray pyrolysis technique

    Science.gov (United States)

    Lmai, F.; Moubah, R.; El Amiri, A.; Abid, Y.; Soumahoro, I.; Hassanain, N.; Colis, S.; Schmerber, G.; Dinia, A.; Lassri, H.

    2016-07-01

    We investigate the magnetic and optical properties of Zn1-xFexO (x = 0, 0.03, 0.05, and 0.07) thin films grown by spray pyrolysis technique. The magnetization as a function of temperature [M (T)] shows a prevailing paramagnetic contribution at low temperature. By using spin wave theory, we separate the M (T) curve in two contributions: one showing intrinsic ferromagnetism and one showing a purely paramagnetic behavior. Furthermore, it is shown that the spin wave theory is consistent with ab-initio calculations only when oxygen vacancies are considered, highlighting the key role played by structural defects in the mechanism driving the observed ferromagnetism. Using UV-visible measurements, the transmittance, reflectance, band gap energy, band tail, dielectric coefficient, refractive index, and optical conductivity were extracted and related to the variation of the Fe content.

  17. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  18. Technique for writing of fiber Bragg gratings over or near preliminary formed macro-structure defects in silica optical fibers

    Science.gov (United States)

    Evtushenko, Alexander S.; Faskhutdinov, Lenar M.; Kafarova, Anastasia M.; Kazakov, Vadim S.; Kuznetzov, Artem A.; Minaeva, Alina Yu.; Sevruk, Nikita L.; Nureev, Ilnur I.; Vasilets, Alexander A.; Andreev, Vladimir A.; Morozov, Oleg G.; Burdin, Vladimir A.; Bourdine, Anton V.

    2017-04-01

    This work presents method for performing precision macro-structure defects "tapers" and "up-tapers" written in conventional silica telecommunication multimode optical fibers by commercially available field fusion splicer with modified software settings and following writing fiber Bragg gratings over or near them. We developed technique for macrodefect geometry parameters estimation via analysis of photo-image performed after defect writing and displayed on fusion splicer screen. Some research results of defect geometry dependence on fusion current and fusion time values re-set in splicer program are represented that provided ability to choose their "the best" combination. Also experimental statistical researches concerned with "taper" and "up-taper" diameter stability as well as their insertion loss values during their writing under fixed corrected splicer program parameters were performed. We developed technique for FBG writing over or near macro-structure defect. Some results of spectral response measurements produced for short-length samples of multimode optical fiber with fiber Bragg gratings written over and near macro-defects prepared by using proposed technique are presented.

  19. Comparison of advanced optical imaging techniques with current otolaryngology diagnostics for improved middle ear assessment (Conference Presentation)

    Science.gov (United States)

    Nolan, Ryan M.; Shelton, Ryan L.; Monroy, Guillermo L.; Spillman, Darold R.; Novak, Michael A.; Boppart, Stephen A.

    2016-02-01

    Otolaryngologists utilize a variety of diagnostic techniques to assess middle ear health. Tympanometry, audiometry, and otoacoustic emissions examine the mobility of the tympanic membrane (eardrum) and ossicles using ear canal pressure and auditory tone delivery and detection. Laser Doppler vibrometry provides non-contact vibrational measurement, and acoustic reflectometry is used to assess middle ear effusion using sonar. These technologies and techniques have advanced the field beyond the use of the standard otoscope, a simple tissue magnifier, yet the need for direct visualization of middle ear disease for superior detection, assessment, and management remains. In this study, we evaluated the use of portable optical coherence tomography (OCT) and pneumatic low-coherence interferometry (LCI) systems with handheld probe delivery to standard tympanometry, audiometry, otoacoustic emissions, laser Doppler vibrometry, and acoustic reflectometry. Comparison of these advanced optical imaging techniques and current diagnostics was conducted with a case study subject with a history of unilateral eardrum trauma. OCT and pneumatic LCI provide novel dynamic spatiotemporal structural data of the middle ear, such as the thickness of the eardrum and quantitative detection of underlying disease pathology, which could allow for more accurate diagnosis and more appropriate management than currently possible.

  20. Taking label-free optical spectroscopy techniques into the operating theatre: biopsy needles and surgical guidance probes (Conference Presentation)

    Science.gov (United States)

    Leblond, Frédéric

    2017-02-01

    Recent advances will be described relating to the development and clinical translation of optical spectroscopy techniques designed to guide surgical interventions in brain and prostate oncology applications. The use of molecular imaging guidance systems can enable true intra-operative tissue identification, increasing the effectiveness of cancer surgery and potentially positively impacting patient survival. Surgical resection is a fundamental cancer treatment, but its effectiveness is reduced by the inability to rapidly and accurately identify cancer margins. We will introduce a portable intraoperative label-free multimodal optical spectroscopy system combining intrinsic fluorescence, diffuse reflectance, and Raman spectroscopy that can identify cancer in situ during surgery. We will show that this on-line guidance system can detect primary cancer such as glioma as well as metastatic melanoma and cancer of the lung and colon with an accuracy, sensitivity, and specificity of 97%, 100%, and 93% respectively. Moreover, a method will be presented, along with preliminary tissue classification results, based on the interrogation of whole human prostates from prostatectomies. The development and in vivo validation of an optical brain needle biopsy instrument will be presented demonstrating its ability to detect bulk tumor using Raman spectroscopy with the goal of reducing the number of non-diagnostic samples during a procedure. The extraction of tissue can cause life-threatening hemorrhage because of significant blood vessel injury during the procedure. We will demonstrate that a sub-diffuse optical tomography technique integrated with a commercial biopsy needle can detect the presence of blood vessels to limit the hemorrhage risk.

  1. Techniques for the manufacturing of stiff and lightweight optical mirror panels based on slumping of glass sheets: concepts and results

    Science.gov (United States)

    Canestrari, R.; Ghigo, M.; Pareschi, G.; Basso, S.; Motta, G.; Doro, M.; Giro, E.; Lessio, L.

    2009-08-01

    In the last decade Very High Energy (VHE) gamma-ray astronomy has improved rapidly opening a new window for ground-based astronomy with surprising implications in the theoretical models. Nowadays, it is possible to make imaging, photometry and spectroscopy of sources with good sensitivity and angular resolution using new facilities as MAGIC, HESS and VERITAS. The latest results of astronomy in the TeV band obtained using such facilities demonstrate the essential role of this window for high energy astrophysics. For this reason new projects (e.g. CTA and AGIS) have been started with the aim to increase the sensitivity and expand the energy band coverage. For such telescopes arrays probably tens of thousands of optical mirror panels must be manufactured with an adequate industrial process, then tested and mounted into the telescopes. Because of the high number of mirrors it is mandatory to perform feasibility studies to test various techniques to meet the technical and cost-effectiveness requirements for the next generation TeV telescopes as CTA and AGIS. In this context at the Astronomical Observatory of Brera (INAF-OAB) we have started the investigation of different techniques for the manufacturing of stiff and lightweight optical glass mirror panels. These panels show a sandwich-like structure with two thin glass skins on both sides, the reflective one being optically shaped using an ad-hoc slumping procedure. The technologies here presented can be addressed both for primary or secondary mirrors for the next generation of Cherenkov telescopes. In this paper we present and discuss the different techniques we are investigating with some preliminary results obtained from test panels realized.

  2. Study on optical nonlinearities of ZnO-Nb2O5-TeO2 glass with time-resolved four-wave mixing technique

    Institute of Scientific and Technical Information of China (English)

    Li Jiang(江丽); Shi'an Zhang(张诗按); Yufei Wang(王宇飞); Zhenrong Sun(孙真荣); Zugeng Wang(王祖赓); Jian Lin(林健); Wenhai Huang(黄文旵); Zhizhan Xu(徐至展); Ruxin Li(李儒新)

    2004-01-01

    We investigated nonlinear optical properties of ZnO-Nb2O5-TeO2 glass excited by a femtosecond laser with time-resolved four-wave mixing (FWM) technique. The unusual FWM signals were observed in samples with ZnO dopant. The mechanism for the optical nonlinearities was discussed.

  3. Measurement of the amplitude and phase transfer functions of an optical modulator using a heterodyne technique

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2001-01-01

    We present a new technique that measures the full amplitude and phase transfer curves of the modulator as a function of the applied bias, from which the small signal α-parameter can be calculated. The technique measures the amplitude and phase transfer functions simultaneously and directly......, compared to techniques where a time-consuming data analysis is necessary to calculate the a-parameter and an additional measurement is necessary to estimate the phase. Additionally, the chirp profile for all operation points can be calculated....

  4. Building a Pulse Detector using the Frequency Resolved Optical Gating Technique

    Energy Technology Data Exchange (ETDEWEB)

    Vallin, J

    2004-02-05

    We show how to construct a diagnostic optical layout known as Frequency Resolved Optical Gating (FROG) for an ir mode-locked laser by using the nonlinear effect known as second harmonic generation (SHG). In this paper, we explain the principle of operation and the theory upon which this diagnostic is based. Moreover, we described the procedure used to measure the duration and frequency components of a pulse. This process consists of calibrating the scales of a two-dimensional image, time delay vs. frequency, known as FROG spectrogram or FROG trace. This calibration of the time delay scale yields the correspondence between a pixel and time delay. Similarly, the calibration of the frequency scale yields the correspondence between a pixel, and frequency.

  5. Z-scan technique for investigation of the noninstantaneous optical Kerr nonlinearity.

    Science.gov (United States)

    Gu, Bing; Wang, Hui-Tian; Ji, Wei

    2009-09-15

    By treating laser-induced optical Kerr nonlinearity as a noninstantaneous decaying process, we present the pulse-duration-dependent Z-scan analytical expressions for an arbitrary aperture and an arbitrary nonlinear magnitude. This theory has the capacity to characterize the third-order nonlinear refraction induced by a laser pulse with its temporal duration being much longer than or comparable to the recovery time of the nonlinear effect. Through Z-scan measurements at different pulse durations, the nonlinear refractive coefficient and the recovery time could be determined unambiguously and simultaneously. Furthermore, the theory can be utilized to confirm whether the measured optical Kerr nonlinearity is instantaneous or noninstantaneous with respect to the given pulse duration.

  6. Combination of optical coherence tomography and reflectometry technique for eye measurement

    Science.gov (United States)

    Lu, Hui; Wang, Michael R.

    2013-03-01

    A spectral domain optical coherence tomography system is integrated with an optical reflectometer to provide dualfunctional eye measurement. The system is capable of performing anterior segment imaging and tear film thickness evaluation at the same time. The axial resolution of the anterior segment imaging is 6μm while for tear film thickness measurement the resolution is about 21 nm. We use the integrated device to examine a model eye with artificial tear film. Structures such as the cornea, the ciliary muscle, and the front boundary of the crystalline lens are clearly visible. Artificial tear film thickness is determined simultaneously with anterior segment imaging. The integrated device is also flexible for separated anterior segment imaging or tear thickness evaluation.

  7. Improving performance of optical fibre chaotic communication by dispersion compensation techniques

    Institute of Scientific and Technical Information of China (English)

    Zhang Jian-Zhong; Wang Yun-Cai; Wang An-Bang

    2008-01-01

    This paper numerically investigates the effects of dispersion on optical fibre chaotic communication,and proposes a dispersion compensation scheme to improve the performance of optical fibre chaotic communication system.The obtained results show that the transmitter-receiver synchronization progressively degrades and the signal-to-noise ratio of the recovered message deteriorates as the fibre length increases due to the dispersion accumulation.Two segments of 2.5-km dispersion-compensating fibres are symmetrically placed at both ends of a segment of 245-km nonzero dispersionshifted fibre with low dispersion in one compensation period.The numerical results show that the signal-to-noise ratio of the extracted 1 GHz sinusoidal message is improved from-2.92 dB to 15.38 dB by this dispemion compensation for the transmission distance of 500 km.

  8. Passive Optical Technique to Measure Physical Properties of a Vibrating Surface

    Science.gov (United States)

    2014-01-01

    was 25 megapascals, but the brief time produced only a small surface wave that propagated away from the point of impact. Sequence left to right are...optics treatise on reflectance, and defined relevant essentials of reflectance, first introducing the term bidirectional reflectance distribution...chosen to match the spatial extent of the data, ω=2π/λ is the frequency of the surface wave , λ is the wavelength of the surface wave , and ft is the time

  9. Study of optical techniques for the Ames unitary wind tunnel. Part 5: Infrared imagery

    Science.gov (United States)

    Lee, George

    1992-01-01

    A survey of infrared thermography for aerodynamics was made. Particular attention was paid to boundary layer transition detection. IR thermography flow visualization of 2-D and 3-D separation was surveyed. Heat transfer measurements and surface temperature measurements were also covered. Comparisons of several commercial IR cameras were made. The use of a recently purchased IR camera in the Ames Unitary Plan Wind Tunnels was studied. Optical access for these facilities and the methods to scan typical models was investigated.

  10. Modulation techniques for deep-space pulse-position modulation (PPM) optical communication

    Science.gov (United States)

    Rayman, Marc D.; Robinson, Deborah L.

    1988-01-01

    The extremely energy-efficient pulse-position modulation (PPM) format is being actively developed as a basis for optical communications with deep-space probes. Attention is presently given to different modulation schemes for the efficient production of laser pulses over a broad range of repetition rates. Both Q-switching and cavity dumping modulation methods are available for the envisioned diode-pumped Nd:YAG laser source. Numerical calculation results are presented for cavity-dumping.

  11. Nonlinear Transformation Optics Techniques in the Design of Counter-Directed Energy Weapon Shields for Satellites

    Science.gov (United States)

    2012-12-01

    or proof, rather as a review and reference for subsequent sections. Brau’s Modern Problems in Electrodynamics and Mill’s Nonlinear Optics are both... Modern Problems in Electrodynamics , follows from the Lorentz-Drude Model for the polarization of the atom[2]. In this model, the electron is harmonically...2] C. A. Brau, Modern Problems in Classical Electrodynamics , New York: Oxford University Press, 2004. [3] K. Than, “Scientists Create Cloak of

  12. Qualification of a truly distributed fiber optic technique for strain and temperature measurements in concrete structures

    Science.gov (United States)

    Henault, J. M.; Salin, J.; Moreau, G.; Delepine-Lesoille, S.; Bertand, J.; Taillade, F.; Quiertant, M.; Benzarti, K.

    2011-04-01

    Structural health monitoring is a key factor in life cycle management of infrastructures. Truly distributed fiber optic sensors are able to provide relevant information on large structures, such as nuclear power plants or nuclear waste disposal facilities. The sensing chain includes an optoelectronic unit and a sensing cable made of one or more optical fibers. A new instrument based on Optical Frequency Domain Reflectometry (OFDR), enables to perform temperature and strain measurements with a centimeter scale spatial resolution over hundred of meters and with a level of precision equal to 1 μ strain and 0.1 °C. Several sensing cables are designed with different materials targeting to last for decades, either embedded in the concrete or attached to the surface of the structure. They must ensure an optimal transfer of temperature and strain from the concrete matrix to the optical fiber. Based on the European guide FD CEN/TR 14748 "Non-destructive testing - Methodology for qualification of non-destructive tests", a qualification method was developed. Tests were carried out using various sensing cables embedded in the volume or fixed to the surface of plain concrete specimens and representative-scale reinforced concrete structural elements. Measurements were performed with an OFDR instrument, while mechanical solicitations were imposed to the concrete element. Preliminary experiments seem very promising since measurements performed with distributed sensing systems are found comparable to values obtained with conventional sensors used in civil engineering and with the Strength of Materials Modelling. Moreover, the distributed sensing system makes it possible to detect and localize cracks appearing in concrete during the mechanical loading.

  13. An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique

    Science.gov (United States)

    Battista, L.; Sciuto, S. A.; Scorza, A.

    2013-03-01

    In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 × 10-4 m3/s (18.0 l/min) for the mono-directional sensor and a measurement range of ±3.00 × 10-4 m3/s (±18.0 l/min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono-directional configuration, the

  14. Effect of low concentration Sn doping on optical properties of CdS films grown by CBD technique.

    Science.gov (United States)

    Jafari, Atefeh; Zakaria, Azmi; Rizwan, Zahid; Mohd Ghazali, Mohd Sabri

    2011-01-01

    Thin and transparent films of doped cadmium sulfide (CdS) were obtained on commercial glass substrates by Chemical Bath Deposition (CBD) technique. The films were doped with low concentration of Sn, and annealed in air at 300 °C for 45 min. The morphological characterization of the films with different amounts of dopant was made using SEM and EDAX analysis. Optical properties of the films were evaluated by measuring transmittance using the UV-vis spectrophotometer. A comparison of the results revealed that lower concentration of Sn doping improves transmittance of CdS films and makes them suitable for application as window layer of CdTe/CIGS solar cells.

  15. An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique.

    Science.gov (United States)

    Battista, L; Sciuto, S A; Scorza, A

    2013-03-01

    In this work, a simple and low-cost air flow sensor, based on a novel fiber-optic sensing technique has been developed for monitoring air flows rates supplied by a neonatal ventilator to support infants in intensive care units. The device is based on a fiber optic sensing technique allowing (a) the immunity to light intensity variations independent by measurand and (b) the reduction of typical shortcomings affecting all biomedical fields (electromagnetic interference and patient electrical safety). The sensing principle is based on the measurement of transversal displacement of an emitting fiber-optic cantilever due to action of air flow acting on it; the fiber tip displacement is measured by means of a photodiode linear array, placed in front of the entrance face of the emitting optical fiber in order to detect its light intensity profile. As the measurement system is based on a detection of the illumination pattern, and not on an intensity modulation technique, it results less sensitive to light intensity fluctuation independent by measurand than intensity-based sensors. The considered technique is here adopted in order to develop two different configurations for an air flow sensor suitable for the measurement of air flow rates typically occurring during mechanical ventilation of newborns: a mono-directional and a bi-directional transducer have been proposed. A mathematical model for the air flow sensor is here proposed and a static calibration of two different arrangements has been performed: a measurement range up to 3.00 × 10(-4) m(3)∕s (18.0 l∕min) for the mono-directional sensor and a measurement range of ±3.00 × 10(-4) m(3)∕s (±18.0 l∕min) for the bi-directional sensor are experimentally evaluated, according to the air flow rates normally encountered during tidal breathing of infants with a mass lower than 10 kg. Experimental data of static calibration result in accordance with the proposed theoretical model: for the mono

  16. WDM Optical Access Network for Full-Duplex and Reconfigurable Capacity Assignment Based on PolMUX Technique

    Directory of Open Access Journals (Sweden)

    Jose Mora

    2014-12-01

    Full Text Available We present a novel bidirectional WDM-based optical access network featuring reconfigurable capacity assignment. The architecture relies on the PolMUX technique allowing a compact, flexible, and bandwidth-efficient router in addition to source-free ONUs and color-less ONUs for cost/complexity minimization. Moreover, the centralized architecture contemplates remote management and control of polarization. High-quality transmission of digital signals is demonstrated through different routing scenarios where all channels are dynamically assigned in both downlink and uplink directions.

  17. Formation of Mn-doped SnO2 Nanoparticles Via the Microwave Technique: Structural, Optical and Electrical Properties

    Directory of Open Access Journals (Sweden)

    Numan Salah

    2016-03-01

    increasing the Mn content. The activation energy of Mn- doped SnO2 NPs was also calculated, and was found to increase from 0.53 to 1.21 eV by varying the Mn dopant from 0.1 to 5 mol%. These results show that the microwave technique is a powerful tool that can be used to produce a high yield of ultrafine SnO2 NPs. Moreover, Mn was found to be a proper activator for tuning the optical and electrical properties of this material, for its application as a dilute magnetic semiconductor or spintronic devices.

  18. Correlation of breast tissue histology and optical signatures to improve margin assessment techniques

    Science.gov (United States)

    Kennedy, Stephanie; Caldwell, Matthew; Bydlon, Torre; Mulvey, Christine; Mueller, Jenna; Wilke, Lee; Barry, William; Ramanujam, Nimmi; Geradts, Joseph

    2016-06-01

    Optical spectroscopy is sensitive to morphological composition and has potential applications in intraoperative margin assessment. Here, we evaluate ex vivo breast tissue and corresponding quantified hematoxylin & eosin images to correlate optical scattering signatures to tissue composition stratified by patient characteristics. Adipose sites (213) were characterized by their cell area and density. All other benign and malignant sites (181) were quantified using a grid method to determine composition. The relationships between mean reduced scattering coefficient (), and % adipose, % collagen, % glands, adipocyte cell area, and adipocyte density were investigated. These relationships were further stratified by age, menopausal status, body mass index (BMI), and breast density. We identified a positive correlation between and % collagen and a negative correlation between and age and BMI. Increased collagen corresponded to increased variability. In postmenopausal women, was similar regardless of fibroglandular content. Contributions from collagen and glands to were independent and equivalent in benign sites; glands showed a stronger positive correlation than collagen to in malignant sites. Our data suggest that scattering could differentiate highly scattering malignant from benign tissues in postmenopausal women. The relationship between scattering and tissue composition will support improved scattering models and technologies to enhance intraoperative optical margin assessment.

  19. Application of real image display and generation technique in space optical system

    Science.gov (United States)

    He, Ruicong; Lin, Li

    2014-11-01

    In space optical system, image display and generation can be influenced by various factors such as stray light, space distance, orbit parameters and so on. To acquire accurate and clear image, these factors should be considered. Before acquiring the real image, simulation is necessary. Through comparing the simulated image with the real one, accuracy can be proved. This paper focuses on building a three-dimensional (3D) model of a satellite and simulating its orbit according to the real data. The 3D images of the satellite should be acquired in specific positions and postures from a camera on another satellite. 3D Studio Max is the software used in the process to build models, simulate and generate images. It is a 3D computer graphics program for making 3D animations, models, and images. Also in the paper, stray light relevant to the satellite surfaces is analyzed. Tracepro is the software used in the stray light analyze to trace the light on the surfaces. It is an optical engineering software program for designing and analyzing optical and illumination systems. Stray light analyzing result is addicted to the 3D images, so that the images are more precise. Therefore, the final images can be complete images including light intensity information of the satellite surfaces which makes the images more real.

  20. Glaucoma detection using novel optic disc localization, hybrid feature set and classification techniques.

    Science.gov (United States)

    Akram, M Usman; Tariq, Anam; Khalid, Shehzad; Javed, M Younus; Abbas, Sarmad; Yasin, Ubaid Ullah

    2015-12-01

    Glaucoma is a chronic and irreversible neuro-degenerative disease in which the neuro-retinal nerve that connects the eye to the brain (optic nerve) is progressively damaged and patients suffer from vision loss and blindness. The timely detection and treatment of glaucoma is very crucial to save patient's vision. Computer aided diagnostic systems are used for automated detection of glaucoma that calculate cup to disc ratio from colored retinal images. In this article, we present a novel method for early and accurate detection of glaucoma. The proposed system consists of preprocessing, optic disc segmentation, extraction of features from optic disc region of interest and classification for detection of glaucoma. The main novelty of the proposed method lies in the formation of a feature vector which consists of spatial and spectral features along with cup to disc ratio, rim to disc ratio and modeling of a novel mediods based classier for accurate detection of glaucoma. The performance of the proposed system is tested using publicly available fundus image databases along with one locally gathered database. Experimental results using a variety of publicly available and local databases demonstrate the superiority of the proposed approach as compared to the competitors.

  1. Optical nonlinearity of organic dyes as studied by Z-scan and transient grating techniques

    Indian Academy of Sciences (India)

    Umakanta Tripathy; R Justin Rajesh; Prem B Bisht; A Subrahamanyam

    2002-12-01

    The excited state absorption cross-section of 5,5′-dichloro-11-diphenylamino- 3,3′-diethyl-10,12-ethylinethiatricarbocyanine perchlorate (IR140) have been measured by using a single beam transmission technique. Z-scan experiments have been used to find out a few nonlinear parameters. The excited state relaxation times have also been measured by using laser induced transient grating (LITG) technique.

  2. Analysis technique for quantifying the effectiveness of optical-proximity-corrected photomasks and its application to defect printability

    Science.gov (United States)

    Arthur, Graham G.; Martin, Brian

    1999-04-01

    An analysis technique for quantifying the effectiveness of optical proximity corrected (OPC) photomasks is described. The methodology is able to account for reticle manufacturing tolerances and has a number of applications including the optimization of OPC features and, in the examples described, the analysis of defect printability. The results presented here are generated using aerial image measurements from PROLITH/2, but the technique can be directly transferred to resist image measurements using 3D simulation tools such as PROLITH/3D where other factors such as swing curve effects caused by wafer topography could also be analyzed. With inspection tools such as scanning electron or atomic force microscopes and appropriate image processing and analysis software it should also be possible to apply this methodology to practical results.

  3. Triple-Play and 60-GHz Radio-over-Fiber Techniques for Next-Generation Optical Access Networks

    DEFF Research Database (Denmark)

    Llorente, R.; Walker, S.; Tafur Monroy, Idelfonso

    2011-01-01

    Radio-over-fiber techniques apply to fiber-to-thehome distributions to reach the customer premises with the services to be received with full-standard low-cost equipment. Bi-directional coarse wavelength division multiplexing (CWDM) radio-over-fiber transmission of triple-format full-standard ort......Radio-over-fiber techniques apply to fiber-to-thehome distributions to reach the customer premises with the services to be received with full-standard low-cost equipment. Bi-directional coarse wavelength division multiplexing (CWDM) radio-over-fiber transmission of triple-format full...... performance of radio-over-fiber optical transmission employing vertical-cavity surface-emitting lasers (VCSELs), and further wireless transmission, of standard OFDM UWB signals is reported when operating in the 60-GHz radio band. Performance is evaluated at 1.44 Gbit/s bitrate. PON transmission distance up...

  4. Brillouin optical time domain reflectometry for fast detection of dynamic strain incorporating double-edge technique

    CERN Document Server

    Shangguan, Mingjia; Xia, Haiyun; Qiu, Jiawei; Shentu, Guoliang; Dou, Xiankang; Zhang, Qiang; Pan, Jian-wei

    2016-01-01

    For the first time, a direct detection BOTDR is demonstrated for distributed dynamic strain sensing incorporating double-edge technique, time-division multiplexing technique and upconversion technique. The double edges are realized by using the transmission curve and reflection curve of an all-fiber Fabry-Perot interferometer (FPI). Benefiting from the low loss of the fiber at, the time-division multiplexing technique is performed to realize the double-edge technique by using only a single-channel FPI and only one piece of a detector. In order to detect the weak spontaneous Brillouin backscattering signal efficiently, a fiber-coupled upconversion detector is adopted to upconvert the backscattering signal at 1548.1 nm to 863 nm, which is detected by a Si-APD finally. In the experiment, dynamic strain disturbance up to 1.9m{\\epsilon} over 1.5 km of polarization maintaining fiber is detected at a sampling rate of 30 Hz. An accuracy of 30{\\mu}{\\epsilon} and spatial resolution of 0.6 m is realized.

  5. Coding techniques to mitigate fading on free-space optical communication links

    Science.gov (United States)

    Henniger, Hennes; Epple, Bernhard; Milner, Stuart D.; Davis, Christopher C.

    2008-08-01

    Free-space directional communication links (FSO) experience short-term link outages or fades because of atmospheric turbulence, and longer term link outages because of obscuration resulting from either atmospheric conditions, beam pointing errors, or temporary line-of-sight obstructions for links from mobile or static nodes. Various approaches can be used to mitigate these effects. Physical-layer techniques, such as dynamic thresholding, time delayed diversity, and data encoding can significantly reduce the effects of short term (millisecond scale) outages caused by deep turbulenceinduced fades. Outages on a longer term (second scale) producing large data loss can be mitigated by packet-layer largeblock, error protection techniques. In this paper, we will first introduce physical-layer mitigation techniques. Second we present experimental data comparing the latencies and throughput of different means of packet-based error protection techniques. We will discuss the influence of error protection techniques to quality of service issues like error probability and delay and further compare this with service requirements given by the application.

  6. Optical properties of thin flms of MEH-PPV produced by the spin-coating technique at different rotational speeds

    Directory of Open Access Journals (Sweden)

    Paulo Sérgio Soares Guimarães

    2008-08-01

    Full Text Available We present a study on the optical properties of thin flms of poly[2-methoxy-5-(20-ethyl-hexyloxy-1,4-phenylene vinylene] (MEH-PPV produced at a concentration of 10 mg/ml xylene. The solution was deposited onto glass substrates by the spin-coating technique at different rotational speeds (300, 1000 and 4000 rpm. We study the effect of rotational speeds on the sample at 300 K, by analyzing the photoluminescence (PL spectra at different points of the polymeric flm. We also analyze the effects of the excitation power on the optical behavior of MEH-PPV at 300 K. At low temperatures the PL spectra of sample A1000 (1000 rpm show a narrow peak for the electronic transition and a series of vibronic sidebands which reveal the electron coupling with two different vibronic modes. In the temperature range of 130 K to 290 K, we analyze systematically the transition lineshapes in the optical spectra using Gaussian curves.

  7. The Variation of Optical Band Gap for ZnO:In Films Prepared by Sol-Gel Technique

    Directory of Open Access Journals (Sweden)

    Guomei Tang

    2013-01-01

    Full Text Available ZnO:In films with different concentrations (0–5 at.% are successfully synthesized on quartz substrates using sol-gel technique. The structure, morphology, and optical properties of ZnO:In films are investigated by X-ray diffraction, atomic force microscopy, and UV-visible spectrophotometer. It is found that all the films with columnar structural morphology grow along the preferred [001] orientation and the incorporation of indium can improve the crystallinity of ZnO films. The transmittance of the films is about 80% in the visible range. A change of the optical absorption edge from blue shift to red shift is observed for ZnO:In films as the doping concentration increases, which means that the optical band gap first increases and then decreases. The blue shift is due to the Burstein-Moss effect. The sharp jump of the absorption edge from blue-shift to red shift is ascribe to the band gap narrowing caused by the merging of the donor and conduction bands of ZnO:In at high doping concentration.

  8. Third-Order Optical Nonlinearities of Squarylium Dyes with Benzothiazole Donor Groups Measured Using the Picosecond Z-Scan Technique

    Science.gov (United States)

    Li, Zhong-Yu; Xu, Song; Chen, Zi-Hui; Zhang, Fu-Shi; Kasatani, Kazuo

    2011-08-01

    Third-order optical nonlinearities of two squarylium dyes with benzothiazole donor groups (BSQ1 and BSQ2) in chloroform solution are measured by a picosecond Z-scan technique at 532 nm. It is found that the two compounds show the saturation absorption and nonlinear self-focus refraction effect. The molecular second hyperpolarizabilities are calculated to be 7.46 × 10-31 esu and 5.01 × 10-30 esu for BSQ1 and BSQ2, respectively. The large optical nonlinearities of squarylium dyes can be attributed to their rigid and intramolecular charge transfer structure. The difference in γ values is attributed to the chloro group of benzene rings of BSQ2 and the one-photon resonance effect. It is found that the third-order nonlinear susceptibilities of two squarylium dyes are mainly determined by the real parts of χ(3), and the large optical nonlinearities of studied squarylium dyes can be attributed to the nonlinear refraction.

  9. Third-Order Optical Nonlinearities of Squarylium Dyes with Benzothiazole Donor Groups Measured Using the Picosecond Z-Scan Technique

    Institute of Scientific and Technical Information of China (English)

    LI Zhong-Yu; XU Song; CHEN Zi-Hui; ZHANG Fu-Shi; KASATANI Kazuo

    2011-01-01

    @@ Third-order optical nonlinearities of two squarylium dyes with benzothiazole donor groups (BSQ1 and BSQ2)in chloroform solution are measured by a picosecond Z-scan technique at 532 nm.It is found that the two compounds show the saturation absorption and nonlinear self-focus refraction effect.The molecular second hyperpolarizabilities are calculated to be 7.46×10-31 esu and 5.01×10-30 esu for BSQ1 and BSQ2, respectively.The large optical nonlinearities of squarylium dyes can be attributed to their rigid and intramolecular charge transfer structure.The difference in γvalues is attributed to the chloro group of benzene rings of BSQ2 and the one-photon resonance effect.It is found that the third-order nonlinear susceptibilities of two squarylium dyes are mainly determined by the real parts of X(3), and the large optical nonlinearities of studied squarylium dyes can be attributed to the nonlinear refraction.

  10. Grade-2 Teflon (AF1601) PCF for optical communication using 2D FDTD technique: a simplest design

    Science.gov (United States)

    Muduli, N.; Achary, J. S. N.; Padhy, Hemanta ku.

    2016-04-01

    A nonlinear ytterbium-doped rectangular proposed PCF structure of inner and outer cladding is used to analyze effective mode field area (Aeff), nonlinear coefficient (γ), dispersion (D), and confinement loss (CL) in a wide range of wavelength. The fabrication of PCF structure is due to different size doped air hole, pitch, and air hole diameter in a regular periodic geometrical array fashion. The various property of PCF structure such as mode field area, nonlinear coefficient, dispersion, and confinement loss are analyzed by implementing 2D FDTD technique. The above PCF property investigated using suitable parameters like Λ1, ?, ?, and ? in three different situations is discussed in simulation. The high nonlinear coefficient and dispersion property of PCF structure are tailored by setting the cladding parameter. However, highly nonlinear fibers with nonzero dispersion at the wavelength of 1.55 μm are very attractive for a range of optical communication application such as laser amplifier, pulse compression, wavelength conversion, all optical switching, and supercontinuum generation. So our newly proposed ytterbium-doped PCF seems to be most suitable exclusively for supercontinuum generation and nonlinear fiber optics. Finally, it is observed that ytterbium-doped Teflon (AF1601) PCF has more nonlinear coefficient (γ(λ) = 65.27 W-1 km-1) as compared to pure silica PCF (γ(λ) = 52 W-1 km-1) design to have same mode field area (Aeff) 1.7 μm2 at an operating wavelength of 1.55 μm.

  11. Applicability of quantitative optical imaging techniques for intraoperative perfusion diagnostics: a comparison of laser speckle contrast imaging, sidestream dark-field microscopy, and optical coherence tomography

    Science.gov (United States)

    Jansen, Sanne M.; de Bruin, Daniel M.; Faber, Dirk J.; Dobbe, Iwan J. G. G.; Heeg, Erik; Milstein, Dan M. J.; Strackee, Simon D.; van Leeuwen, Ton G.

    2017-08-01

    Patient morbidity and mortality due to hemodynamic complications are a major problem in surgery. Optical techniques can image blood flow in real-time and high-resolution, thereby enabling perfusion monitoring intraoperatively. We tested the feasibility and validity of laser speckle contrast imaging (LSCI), optical coherence tomography (OCT), and sidestream dark-field microscopy (SDF) for perfusion diagnostics in a phantom model using whole blood. Microvessels with diameters of 50, 100, and 400 μm were constructed in a scattering phantom. Perfusion was simulated by pumping heparinized human whole blood at five velocities (0 to 20 mm/s). Vessel diameter and blood flow velocity were assessed with LSCI, OCT, and SDF. Quantification of vessel diameter was feasible with OCT and SDF. LSCI could only visualize the 400-μm vessel, perfusion units scaled nonlinearly with blood velocity. OCT could assess blood flow velocity in terms of inverse OCT speckle decorrelation time. SDF was not feasible to measure blood flow; however, for diluted blood the measurements were linear with the input velocity up to 1 mm/s. LSCI, OCT, and SDF were feasible to visualize blood flow. Validated blood flow velocity measurements intraoperatively in the desired parameter (mL·g-1) remain challenging.

  12. General solution to nonlinear optical quantum graphs using Dalgarno-Lewis summation techniques

    CERN Document Server

    Lytel, Rick; Kuzyk, Mark G

    2016-01-01

    We develop an algorithm to apply the Dalgarno-Lewis (DL) perturbation theory to quantum graphs with multiple, connected edges. We use it to calculate the nonlinear optical hyperpolarizability tensors for graphs and show that it replicates the sum over states computations, but executes ten to fifty times faster. DL requires only knowledge of the ground state of the graph, eliminating the requirement to determine all possible degeneracies of a complex network. The algorithm is general and may be applied to any quantum graph.

  13. Elasto-Optical Properties of Thin Polymer Films by Prism Coupling Technique

    Science.gov (United States)

    Ay, Feridun; Agan, Sedat; Kocabas, Askin; Aydinli, Atilla

    2004-05-01

    Reliable measurement of stress dependent refractive index of thin polymer films has been achieved. The effect of the applied stress on the refractive index and birefringence of the films was investigated. The out-of-plane elastic moduli of the thin polymer films were deduced by using the same prism coupling setup. Three dimensional finite element method (FEM) analysis was used to obtain the principal stresses for each polymer film and combining them with the stress dependent refractive index measurements, the elasto-optic coefficients of the polymer films were determined, for the first time.

  14. Invited Article: The coherent optical laser beam recombination technique (COLBERT) spectrometer: Coherent multidimensional spectroscopy made easier

    Science.gov (United States)

    Turner, Daniel B.; Stone, Katherine W.; Gundogdu, Kenan; Nelson, Keith A.

    2011-08-01

    We have developed an efficient spectrometer capable of performing a wide variety of coherent multidimensional measurements at optical wavelengths. The two major components of the largely automated device are a spatial beam shaper which controls the beam geometry and a spatiotemporal pulse shaper which controls the temporal waveform of the femtosecond pulse in each beam. We describe how to construct, calibrate, and operate the device, and we discuss its limitations. We use the exciton states of a semiconductor nanostructure as a working example. A series of complex multidimensional spectra—displayed in amplitude and real parts—reveals increasingly intricate correlations among the excitons.

  15. Measurement of micro moulded parts by Computed Tomography and comparison to optical and tactile techniques

    DEFF Research Database (Denmark)

    Yagüe, J.A.; Tosello, Guido; Carmignato, S

    2011-01-01

    This paper focuses on dimensional verification of two micro-injection moulded components, selected from actual industrial productions, using CT metrological tools. In addition to CT scanning, also a tactile Coordinate Measuring Machine (CMM) with sub-micrometer uncertainty and an Optical Coordinate...... Measuring Machine (OCMM) allowing fast measurements suitable for in-line quality control were employed as validation instruments. The experimental work carried out and the analysis of the results provide valuable conclusions about the advantages and drawbacks of using CT metrology in comparison with CMM...

  16. Vibration-displacement measurement employing phase tracking technique with an optical fiber Michelson interferometer

    Science.gov (United States)

    Ma, Sen; Li, Zhaoying; Xie, Fang

    2011-11-01

    A vibration-displacement measurement system by tracking the phase variation of an optical fiber Michelson interferometer with an electronic feedback loop is presented. The measurement system includes an electronic feedback loop which is used to track the phase variation induced by the measured vibration-displacement and provides a sense of direction of the displacement simultaneously. The measurement system is designed to be capable of measuring vibration-displacement with frequencies up to 200Hz and the measurement resolution can reach 13nm.

  17. Analysis of heat and mass transfers in two-phase flow by coupling optical diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lemaitre, P.; Porcheron, E. [Institut de Radioprotection et de Surete Nucleaire, Saclay (France)

    2008-08-15

    During the course of a hypothetical accident in a nuclear power plant, spraying might be actuated to reduce static pressure in the containment. To acquire a better understanding of the heat and mass transfers between a spray and the surrounding confined gas, non-intrusive optical measurements have to be carried out simultaneously on both phases. The coupling of global rainbow refractometry with out-of-focus imaging and spontaneous Raman scattering spectroscopy allows us to calculate the local Spalding parameter B{sub M}, which is useful in describing heat transfer associated with two-phase flow. (orig.)

  18. Experimental, computational, and analytical techniques for diagnosing breast cancer using optical spectroscopy

    Science.gov (United States)

    Palmer, Gregory M.

    This dissertation presents the results of an investigation into experimental, computational, and analytical methodologies for diagnosing breast cancer using fluorescence and diffuse reflectance spectroscopy. First, the optimal experimental methodology for tissue biopsy studies was determined using an animal study. It was found that the use of freshly excised tissue samples preserved the original spectral line shape and magnitude of the fluorescence and diffuse reflectance. Having established the optimal experimental methodology, a clinical study investigating the use of fluorescence and diffuse reflectance spectroscopy for the diagnosis of breast cancer was undertaken. In addition, Monte Carlo-based models of diffuse reflectance and fluorescence were developed and validated to interpret these data. These models enable the extraction of physically meaningful information from the measured spectra, including absorber concentrations, and scattering and intrinsic fluorescence properties. The model was applied to the measured spectra, and using a support vector machine classification algorithm based on physical features extracted from the diffuse reflectance spectra, it was found that breast cancer could be diagnosed with a cross-validated sensitivity and specificity of 82% and 92%, respectively, which are substantially better than that obtained using a conventional, empirical algorithm. It was found that malignant tissues had lower hemoglobin oxygen saturation, were more scattering, and had lower beta-carotene concentration, relative to the non-malignant tissues. It was also found that the fluorescence model could successfully extract the intrinsic fluorescence line shape from tissue samples. One limitation of the previous study is that a priori knowledge of the tissue's absorbers and scatterers is required. To address this limitation, and to improve upon the method with which fiber optic probes are designed, an alternate approach was developed. This method used a

  19. Study of optical techniques for the Ames unitary wind tunnels. Part 1: Schlieren

    Science.gov (United States)

    Lee, George

    1992-01-01

    Alignment procedures and conceptual designs for the rapid alignment of the Ames Unitary Wind Tunnel schlieren systems were devised. The schlieren systems can be aligned by translating the light source, the mirrors, and the knife edge equal distances. One design for rapid alignment consists of a manual pin locking scheme. The other is a motorized electronic position scheme. A study of two optical concepts which can be used with the schlieren system was made. These are the 'point diffraction interferometers' and the 'focus schlieren'. Effects of vibrations were studied.

  20. An elegant technique for ex vivo imaging in experimental research—Optical coherence tomography (OCT)

    DEFF Research Database (Denmark)

    Tschernig, T.; Thrane, Lars; Jørgensen, Thomas Martini

    2013-01-01

    Optical coherence tomography (OCT) is an elegant technology for imaging of tissues and organs and has been established for clinical use for around a decade. Thus, it is used in vivo but can also serve as a valuable ex vivo imaging tool in experimental research. Here, a brief overview is given...... with a focus on an ex vivo application of OCT. Image and video examples of freshly obtained murine lungs are included. The main advantage of OCT for ex vivo analysis is the non-contact, non-invasive, and non-destructive fast acquisition of a three-dimensional data set with micrometer-resolution....

  1. Investigation of HIV-1 infected and uninfected cells using the optical trapping technique

    CSIR Research Space (South Africa)

    Ombinda-Lemboumba, Saturnin

    2017-02-01

    Full Text Available (NLC) Biophotonics group sombindalemboumba@csir.co.za Slide 2 Outline • Introduction • Aim • Background • Optical trapping of living cell • Transmission spectroscopy • Experimental setup • Results • Conclusions © CSIR 2017 www....csir.co.za Slide 3 Introduction • Current HIV diagnostics tests are: • Too expensive (CD4 count, PCR) • Require laboratory facilities and high skilled personnel • Long testing time (ELISA, P24 test, Reverse transcriptase test) • New point-of-care diagnostics...

  2. A novel optical technique to characterize fiberization of textured vegetable proteins under high-moisture extrusion

    Science.gov (United States)

    Yao, Gang; Liu, Keshun; Hsieh, Fu-Hung

    2004-11-01

    There have been great interests in using twin-screw extruders under high moisture conditions to produce textured vegetable proteins. Unlike the low moisture extrusion counterpart, a product extruded under high moisture can have well-defined fiber orientation and bears a strong resemblance to muscle meat. The textural properties of such extruded products are important for consumer acceptance. In this study, we developed a novel fluorescence polarization based technique that measures the fiber formation of extruded protein products. The experimental results using our new technique showed good agreements with results obtained from visual inspection and digital imaging of the dissected samples. The new technique provides an in vivo and noninvasive approach to characterize the fiber formation of textured vegetable proteins under high moisture extrusion. It has a potential to be used as a real time monitoring tool in food extrusion studies.

  3. Three-dimensional reconstruction of flame temperature and emissivity distribution using optical tomographic and two-colour pyrometric techniques

    Science.gov (United States)

    Moinul Hossain, Md; Lu, Gang; Sun, Duo; Yan, Yong

    2013-07-01

    This paper presents an experimental investigation, visualization and validation in the three-dimensional (3D) reconstruction of flame temperature and emissivity distributions by using optical tomographic and two-colour pyrometric techniques. A multi-camera digital imaging system comprising eight optical imaging fibres and two RGB charged-couple device (CCD) cameras are used to acquire two-dimensional (2D) images of the flame simultaneously from eight equiangular directions. A combined logical filtered back-projection (LFBP) and simultaneous iterative reconstruction and algebraic reconstruction technique (SART) algorithm is utilized to reconstruct the grey-level intensity of the flame for the two primary colour (red and green) images. The temperature distribution of the flame is then determined from the ratio of the reconstructed grey-level intensities and the emissivity is estimated from the ratio of the grey level of a primary colour image to that of a blackbody source at the same temperature. The temperature measurement of the system was calibrated using a blackbody furnace as a standard temperature source. Experimental work was undertaken to validate the flame temperature obtained by the imaging system against that obtained using high-precision thermocouples. The difference between the two measurements is found no greater than ±9%. Experimental results obtained on a laboratory-scale propane fired combustion test rig demonstrate that the imaging system and applied technical approach perform well in the reconstruction of the 3D temperature and emissivity distributions of the sooty flame.

  4. Structural and optical properties of Zn1−xNixTe thin films prepared by electron beam evaporation technique

    Directory of Open Access Journals (Sweden)

    Arshad Mahmood

    2015-02-01

    Full Text Available Zn1−xNixTe thin films with different composition (x=0.0, 0.05, 0.10, 0.15 and 0.20 were deposited on glass substrate by electron beam evaporation technique followed by its characterization using advanced structural and optical analysis techniques. Structural properties of the prepared thin films were studied by X-ray diffraction (XRD. The XRD patterns revealed that the binary compounds transformed into a ternary compound with cubic structure having preferred orientation along the c-direction with (111 planes. Composition analysis of the films was determined by energy dispersive analysis of X-rays (EDAX and found to be in agreement with the precursor composition. Optical properties such as extinction coefficient (k and band gap energy of these films were examined by using a spectroscopic ellipsometer. It was found that the extinction coefficient (k increased with the addition of Ni content in the alloy. In comparison, the band gap energy was also determined by using transmission spectra and found to be agreed with that of the ellipsometric results. These analyses confirm that the band gap energy decreases with the increase of Ni content in the alloy.

  5. Combining Gabor and Talbot bands techniques to enhance the sensitivity with depth in Fourier domain optical coherence tomography

    Science.gov (United States)

    Bradu, Adrian; Marques, Manuel J.; Bouchal, Petr; Podoleanu, Adrian Gh.

    2013-03-01

    The purpose of this study was to show how to favorably mix two e_ects to improve the sensitivity with depth in Fourier domain optical coherence tomography (OCT): Talbot bands (TB) and Gabor-based fusion (GF) technique. TB operation is achieved by directing the two beams, from the object arm and from the reference arm in the OCT interferometer, along parallel separate paths towards the spectrometer. By changing the lateral gap between the two beams in their path towards the spectrometer, the position for the maximum sensitivity versus the optical path difference in the interferometer is adjusted. For five values of the focus position, the gap between the two beams is readjusted to reach maximum sensitivity. Then, similar to the procedure employed in the GF technique, a composite image is formed by edging together the parts of the five images that exhibited maximum brightness. The combined procedure, TB/GF is examined for four different values of the beam diameters of the two beams. Also we demonstrate volumetric FD-OCT images with mirror term attenuation and sensitivity profile shifted towards higher OPD values by applying a Talbot bands configuration.

  6. Studies on the growth, structural, optical, mechanical properties of 8-hydroxyquinoline single crystal by vertical Bridgman technique

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakaran, SP. [Crystal Growth and Thin Film Laboratory, Department of Physics, Bharathidasan University, Tiruchirappalli 620 024, Tamil Nadu (India); Babu, R. Ramesh, E-mail: rampap2k@yahoo.co.in [Crystal Growth and Thin Film Laboratory, Department of Physics, Bharathidasan University, Tiruchirappalli 620 024, Tamil Nadu (India); Velusamy, P.; Ramamurthi, K. [Crystal Growth and Thin Film Laboratory, Department of Physics, Bharathidasan University, Tiruchirappalli 620 024, Tamil Nadu (India)

    2011-11-15

    Highlights: {yields} Growth of bulk single crystal of 8-hydroxyquinoline (8-HQ) by vertical Bridgman technique for the first time. {yields} The crystalline perfection is reasonably good. {yields} The photoluminescence spectrum shows that the material is suitable for blue light emission. -- Abstract: Single crystal of organic nonlinear optical material, 8-hydroxyquinoline (8-HQ) of dimension 52 mm (length) x 12 mm (dia.) was grown from melt using vertical Bridgman technique. The crystal system of the material was confirmed by powder X-ray diffraction analysis. The crystalline perfection of the grown crystal was examined by high-resolution X-ray diffraction study. Low angular spread around 400'' of the diffraction curve and the low full width half maximum values show that the crystalline perfection is reasonably good. The recorded photoluminescence spectrum shows that the material is suitable for blue light emission. Optical transmittance for the UV and visible region was measured and mechanical strength was estimated from Vicker's microhardness test along the growth face of the grown crystal.

  7. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, Yu L; Kalchenko, V V [Department of Veterinary Resources, Weizmann Institute of Science, Rehovot, 76100 (Israel); Astaf' eva, N G [V.I.Razumovsky Saratov State Medical University, Saratov (Russian Federation); Meglinski, I V [N.G. Chernyshevsky Saratov State University, Saratov (Russian Federation)

    2014-08-31

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  8. A simple and inexpensive optical technique to help students visualize mode shapes.

    Science.gov (United States)

    Moore, Thomas R; Cannaday, Ashley E; Zietlow, Sarah A

    2012-03-01

    An imaging technique is introduced that is suitable for visualizing the mode shapes of vibrating structures in an educational setting. The method produces images similar to those obtained using electronic speckle pattern interferometry (ESPI), but it can be implemented for less than 1/10 the cost of a commercial ESPI system, and the apparatus is simple enough that it can be constructed by undergraduate students. This technique allows for real-time visualization of the normal modes and deflection shapes of harmonically vibrating structures, including those with shapes that make generating Chladni patterns with sand or powder impossible. The theory of operation and construction details are discussed.

  9. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    Science.gov (United States)

    Kuznetsov, Yu L.; Kalchenko, V. V.; Astaf'eva, N. G.; Meglinski, I. V.

    2014-08-01

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials.

  10. Digital compensation of cross-phase modulation distortions using perturbation technique for dispersion-managed fiber-optic systems.

    Science.gov (United States)

    Liang, Xiaojun; Kumar, Shiva; Shao, Jing; Malekiha, Mahdi; Plant, David V

    2014-08-25

    A digital compensation scheme based on a perturbation theory for mitigation of cross-phase modulation (XPM) distortions is developed for dispersion-managed fiber-optic communication systems. It is a receiver-side scheme that uses a hard-decision unit to estimate data for the calculation of XPM fields using the perturbation technique. The intra-channel nonlinear distortions are removed by intra-channel digital backward propagation (DBP) based on split-step Fourier scheme before the hard-decision unit. The perturbation technique is shown to be effective in mitigating XPM distortions. However, wrong estimations in the hard-decision unit result in performance degradation. A hard-decision correction method is proposed to correct the wrong estimations. Numerical simulations show that the hybrid compensation scheme with DBP for dispersion and intra-channel nonlinear impairments compensation and the perturbation technique for XPM compensation brings up to 3.7 dBQ and 1.7 dBQ improvements as compared with the schemes of linear compensation only and intra-channel DBP, respectively. The perturbation technique for XPM compensation requires only one-stage (or two-stage when hard-decision correction is applied) compensation and symbol-rate signal processing.

  11. High-speed imaging optical techniques for shockwave and droplets atomization analysis

    Science.gov (United States)

    Slangen, Pierre R.; Lauret, Pierre; Heymes, Frederic; Aprin, Laurent; Lecysyn, Nicolas

    2016-12-01

    Droplets atomization by shockwave can act as a consequence in domino effects on an industrial facility: aggression of a storage tank (projectile from previous event, for example) can cause leakage of hazardous material (toxic and flammable). As the accident goes on, a secondary event can cause blast generation, impacting the droplets and resulting in their atomization. Therefore, exchange surface increase impacts the evaporation rate. This can be an issue in case of dispersion of such a cloud. The experiments conducted in the lab generate a shockwave with an open-ended shock tube to break up liquid droplets. As the expected shockwave speed is about 400 m/s (˜Mach 1.2), the interaction with falling drops is very short. High-speed imaging is performed at about 20,000 fps. The shockwave is measured using both overpressure sensors: particle image velocimetry and pure in line shadowgraphy. The size of fragmented droplets is optically measured by direct shadowgraphy simultaneously in different directions. In these experiments, secondary breakups of a droplet into an important number of smaller droplets from the shockwave-induced flow are shown. The results of the optical characterizations are discussed in terms of shape, velocity, and size.

  12. Develop techniques for ion implantation of PLZT (lead-lanthanum-zirconate-titanate) for adaptive optics

    Energy Technology Data Exchange (ETDEWEB)

    Batishko, C.R.; Brimhall, J.L.; Pawlewicz, W.T.; Stahl, K.A.; Toburen, L.H.

    1987-07-01

    Research was conducted at Pacific Northwest Laboratory to develop high photosensitivity adaptive optical elements utilizing ion implanted lanthanum-doped lead-zirconate-titanate (PLZT). One centimeter square samples were prepared by implanting ferroelectric and anti-ferroelectric PLZT with a variety of species or combinations of species. These included Ne, O, Ni, Ne/Cr, Ne/Al, Ne/Ni, Ne/O, and Ni/O, at a variety of energies and fluences. An indium-tin oxide (ITO) electrode coating was designed to give a balance of high conductivity and optical transmission at near uv to near ir wavelengths. Samples were characterized for photosensitivity; implanted layer thickness, index of refraction, and density; electrode (ITO) conductivity; and in some cases, residual stress curvature. Thin film anti-ferroelectric PLZT was deposited in a preliminary experiment. The structure was amorphous with x-ray diffraction showing the beginnings of a structure at substrate temperatures of approximately 550/sup 0/C. This report summarizes the research and provides a sampling of the data taken during the report period.

  13. Characterization of thermal, optical and carrier transport properties of porous silicon using the photoacoustic technique

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, Chan Kok [Department of Physics, Faculty of Science, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Mahmood Mat Yunus, W. [Department of Physics, Faculty of Science, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia)], E-mail: mahmood@science.upm.edu.my; Yunus, Wan Md. Zin Wan [Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, 43400 UPM Serdang (Malaysia); Abidin Talib, Zainal [Department of Physics, Faculty of Science, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Kassim, Anuar [Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, 43400 UPM Serdang (Malaysia)

    2008-08-01

    In this work, the porous silicon layer was prepared by the electrochemical anodization etching process on n-type and p-type silicon wafers. The formation of the porous layer has been identified by photoluminescence and SEM measurements. The optical absorption, energy gap, carrier transport and thermal properties of n-type and p-type porous silicon layers were investigated by analyzing the experimental data from photoacoustic measurements. The values of thermal diffusivity, energy gap and carrier transport properties have been found to be porosity-dependent. The energy band gap of n-type and p-type porous silicon layers was higher than the energy band gap obtained for silicon substrate (1.11 eV). In the range of porosity (50-76%) of the studies, our results found that the optical band-gap energy of p-type porous silicon (1.80-2.00 eV) was higher than that of the n-type porous silicon layer (1.70-1.86 eV). The thermal diffusivity value of the n-type porous layer was found to be higher than that of the p-type and both were observed to increase linearly with increasing layer porosity.

  14. Fiber Optic Pressure Sensor of 0–0.36 psi by Multimode Interference Technique

    Directory of Open Access Journals (Sweden)

    A.R. Mejia-Aranda

    2013-10-01

    Full Text Available This paper presents the design, development and tests made to a fiber optic pressure sensor using the multimodal interference methodology (MMI thus, we propose an alternative sensor to the ones available which are limited by high robust environments where the use of them is a potential hazard (explosive gases, corrosion and even electromagnetic fields. The range of work for this sensor is 0 to 0.36 psi, the arrangement used is formed by a laser diode, a sensing element, an electronic amplifying circuit, a data acquisition board and a computer. The sensing element used is a SMS fiber optic structure (singlemode–multimode–singlemode, where a multimode fiber is embedded between two singlemode fibers placed within the contact surface (diaphragm made of a polymeric material; the body of the sensor was made of nylamid. The bending produced in the diaphragm by the pressure inside the body of the sensor generates changes in the transmitted power response carried inside the fiber.

  15. VO 2+ ions in zinc lead borate glasses studied by EPR and optical absorption techniques

    Science.gov (United States)

    Prakash, P. Giri; Rao, J. Lakshmana

    2005-09-01

    Electron paramagnetic resonance (EPR) and optical absorption spectra of vanadyl ions in zinc lead borate (ZnO-PbO-B 2O 3) glass system have been studied. EPR spectra of all the glass samples exhibit resonance signals characteristic of VO 2+ ions. The values of spin-Hamiltonian parameters indicate that the VO 2+ ions in zinc lead borate glasses were present in octahedral sites with tetragonal compression and belong to C 4V symmetry. The spin-Hamiltonian parameters g and A are found to be independent of V 2O 5 content and temperature but changing with ZnO content. The decrease in Δ g∥/Δ g⊥ value with increase in ZnO content indicates that the symmetry around VO 2+ ions is more octahedral. The decrease in intensity of EPR signal above 10 mol% of V 2O 5 is attributed to a fall in the ratio of the number of V 4+ ions ( N4) to the number of V 5+ ions ( N5). The number of spins ( N) participating in resonance was calculated as a function of temperature for VO 2+ doped zinc lead borate glass sample and the activation energy was calculated. From the EPR data, the paramagnetic susceptibility was calculated at various temperatures and the Curie constant was evaluated from the 1/ χ- T graph. The optical absorption spectra show single absorption band due to VO 2+ ions in tetragonally distorted octahedral sites.

  16. Reflection electron energy loss spectroscopy as efficient technique for the determination of optical properties of polystyrene intermixed with gold nanoparticles

    Science.gov (United States)

    Deris, Jamileh; Hajati, Shaaker

    2017-01-01

    The electronic properties (electron inelastic cross section, energy loss function) of a nano-metalized polystyrene obtained by reflection electron energy loss spectroscopy (REELS) in a previous study [J. Deris, S. Hajati, S. Tougaard, V. Zaporojtchenko, Appl. Surf. Sci. 377 (2016) 44-47], which relies on the Yubero-Tougaard method, were used in the complementary application of Kramers-Kronig transformation to determine its optical properties such as the real part (ε1) and imaginary part (ε2) of the dielectric function (ε), refractive index (n), coefficients of extinction (k), reflection (R) and absorption (μ). The degree of intermixing of polystyrene thin film and gold nanoparticles of sizes 5.5 nm was controlled by annealing the sample to achieve a morphology in which the nanoparticles were homogeneously distributed within polystyrene. It is worth noting that no data are available on the optical properties of metalized polymers such as gold nanoparticles intermixed with polystyrene. Therefore, this work is of high importance in terms of both the sample studied here and the method applied. The advantage of the method applied here is that no information on the lateral distribution of the nanocomposite sample is required. This means that the REELS technique has been presented here to suitably, efficiently and easily obtain the optical properties of such nano-metalized polymer in which the metal nanoparticles have been vertically well distributed (homogeneous in depth). Therefore, for vertically homogeneous and laterally inhomogeneous samples, it is possible to make REELS imaging by scanning the sample and thus to make an image of their optical properties.

  17. A novel transceiver of the Y-00 quantum stream cipher with the randomization technique for optical communication with higher security performance

    Science.gov (United States)

    Futami, Fumio; Kato, Kentaro; Hirota, Osamu

    2016-09-01

    For protecting physical layer of optical fiber communication systems, quantum stream cipher called Y-00 and Alpha-Eta is promising. So far, we demonstrated secure and high speed optical fiber communication experiments using Y-00 quantum stream cipher. Our theoretical research revealed that the randomization techniques could enhance the security performance. In this work, we fabricated a novel Y-00 transceiver for GbE where the randomization technique was implemented. The transceiver employed the optical intensity modulated Y-00 quantum stream cipher with intensity levels of 4096. An appropriately designed irregular mapping as the randomization technique was experimentally demonstrated. The transceiver was successfully applied to secure optical fiber transmission of GbE signals.

  18. A technique to measure optical properties of brownout clouds for modeling terahertz propagation.

    Science.gov (United States)

    Fiorino, Steven T; Deibel, Jason A; Grice, Phillip M; Novak, Markus H; Spinoza, Julian; Owens, Lindsay; Ganti, Satya

    2012-06-01

    Brownout, the loss of visibility caused by dust resultant of helicopter downwash, is a factor in the large majority of military helicopter accidents. As terahertz radiation readily propagates through the associated dust aerosols and is attenuated by atmospheric water vapor within short distances, it can provide low-profile imaging that improves effective pilot visibility. In order to model this application of terahertz imaging, it is necessary to determine the optical properties of obscurants at these frequencies. We present here a method of empirical calculation and experimental measurement of the complex refractive index of the obscuring aerosols. Results derived from terahertz time-domain spectral measurements are incorporated into the AFIT CDE Laser Environmental Effects Definition and Reference (LEEDR) software.

  19. Studies of seasonal variations of aerosol optical properties with use of remote techniques

    Science.gov (United States)

    Strzalkowska, Agata; Zielinski, Tymon; Petelski, Tomasz; Pakszys, Paulina; Markuszewski, Piotr; Makuch, Przemyslaw

    2014-05-01

    According to the IPCC report, atmospheric aerosols due to their properties -extinction of Sun and Earth radiation and participation in processes of creation of clouds, are among basic "unknowns" in climate studies. Aerosols have large effect on the radiation balance of the Earth which has a significant impact on climate changes. They are also a key issue in the case of remote sensing measurements. The optical properties of atmospheric aerosols depend not only on their type but also on physical parameters such as pressure, humidity, wind speed and direction. The wide range of properties in which atmospheric aerosols affect Earth's climate is the reason of high unrelenting interest of scientists from different disciplines such as physics, chemistry and biology. Numerous studies have dealt with aerosol optical properties, e.g. Dubovik et al. (2002), but only in a few have regarded the influence of meteorological parameters on the optical properties of aerosols in the Baltic Sea area. Studies of aerosol properties over the Baltic were conducted already in the last forty years, e.g. Zielinski T. et. al. (1999) or Zielinski T. & A. Zielinski (2002). The experiments carried out at that time involved only one measuring instrument -e.g. LIDAR (range of 1 km) measurements and they were conducted only in selected areas of the Polish coastal zone. Moreover in those publications authors did not use measurements performed on board of research vessel (R/V Oceania), which belongs to Institute of Oceanology Polish Academy of Science (IO PAN) or data received from satellite measurements. In 2011 Zdun and Rozwadowska performed an analysis of all data derived from the AERONET station on the Gotland Island. The data were divided into seasons and supplemented by meteorological factors. However, so far no comprehensive study has been carried out for the entire Baltic Sea area. This was the reason to conduct further research of SEasonal Variations of Aerosol optical depth over the Baltic

  20. Evolving techniques in the treatment of macular detachment caused by optic nerve pits.

    Science.gov (United States)

    Cox, M S; Witherspoon, C D; Morris, R E; Flynn, H W

    1988-07-01

    Fourteen patients with macular detachments caused by optic nerve pits were treated for progressive visual loss, cystoid macular changes, or atrophy of the macular retinal pigment epithelium. Photocoagulation of the temporal disc border alone was unsuccessful in two cases but promptly reattached the macula of two patients immobilized after laser surgery. Vitrectomy and gas tamponade improved vision and flattened the macula of three patients over various periods. The detachment recurred in one patient. Prompt and sustained macular reattachment with improved vision was noted after photocoagulation, vitrectomy, and gas tamponade in eight patients, although four required second operations. The prompt reattachment and visual recovery noted in these eight patients surpasses the reported 25% rate of spontaneous resolution.

  1. Optical cell separation from three-dimensional environment in photodegradable hydrogels for pure culture techniques.

    Science.gov (United States)

    Tamura, Masato; Yanagawa, Fumiki; Sugiura, Shinji; Takagi, Toshiyuki; Sumaru, Kimio; Matsui, Hirofumi; Kanamori, Toshiyuki

    2014-05-07

    Cell sorting is an essential and efficient experimental tool for the isolation and characterization of target cells. A three-dimensional environment is crucial in determining cell behavior and cell fate in biological analysis. Herein, we have applied photodegradable hydrogels to optical cell separation from a 3D environment using a computer-controlled light irradiation system. The hydrogel is composed of photocleavable tetra-arm polyethylene glycol and gelatin, which optimized cytocompatibility to adjust a composition of crosslinker and gelatin. Local light irradiation could degrade the hydrogel corresponding to the micropattern image designed on a laptop; minimum resolution of photodegradation was estimated at 20 µm. Light irradiation separated an encapsulated fluorescent microbead without any contamination of neighbor beads, even at multiple targets. Upon selective separation of target cells in the hydrogels, the separated cells have grown on another dish, resulting in pure culture. Cell encapsulation, light irradiation and degradation products exhibited negligible cytotoxicity in overall process.

  2. Optical coherence tomography assessment of a complex bifurcation lesion treated with double kissing Crush technique

    Science.gov (United States)

    Cai, Jin-Zan; Zhang, Yao-Jun; Xu, Tian; Zhu, Yong-Xiang; Mao, Chen-Yu; Bourantas, Christos V.; Crake, Tom; Chen, Shao-Liang

    2017-01-01

    Abstract The DEFINITION (Impact of the complexity of bifurcation lesions treated with drug-eluting stents) study has provided a novel classification to evaluate the complexity of coronary bifurcation lesion according to coronary angiography, but angiographic imaging due to its low resolution and inherited limitation may result in an inaccurate adjudication. We used optical coherence tomography (OCT) to further evaluate the coronary characteristics in a patient with “simple” bifurcation lesion which was classified by the DEFINITION criteria. However, a “complex” bifurcation lesion was defined and confirmed according to the OCT results. A double kissing Crush stenting approach was adopted to treat this “complex” case finally. The immediate and long-term angiographic and OCT results were excellent. OCT may be useful imaging modality to classify complexity of coronary bifurcation lesion and subsequently guide its treatment strategy. PMID:28072714

  3. Optic Nerve Sheath Diameter: Translating a Terrestrial Focused Technique into a Clinical Monitoring Tool for Spaceflight

    Science.gov (United States)

    Mason, Sara; Foy, Millennia; Sargsyan, Ashot; Garcia, Kathleen; Wear, Mary L.; Bedi, Deepak; Ernst, Randy; Van Baalen, Mary

    2015-01-01

    Ultrasonography is increasingly used to quickly measure optic nerve sheath diameter (ONSD) when increased intracranial pressure (ICP) is suspected. NASA Space and Clinical Operations Division has been using ground and on-orbit ultrasound since 2009 as a proxy for ICP in non-acute monitoring for space medicine purposes. In the terrestrial emergency room population, an ONSD greater than 0.59 cm is considered highly predictive of elevated intracranial pressure. However, this cut-off limit is not applicable to the spaceflight setting since over 50% of US Operating Segment (USOS) astronauts have an ONSD greater than 0.60 cm even before launch. Crew Surgeon clinical decision-making is complicated by the fact that many astronauts have history of previous spaceflights. Our data characterize the distribution of baseline ONSD in the astronaut corps, its longitudinal trends in long-duration spaceflight, and the predictive power of this measure related to increased ICP outcomes.

  4. Versatile technique to functionalize optical microfibers via a modified sol-gel dip-coating method.

    Science.gov (United States)

    Xu, Z Y; Li, Y H; Wang, L J

    2014-01-01

    We present a convenient and versatile technique to functionalize microfibers by depositing sol-gel jackets via a modified dip-coating method. This was elucidated by gain-functionalizing microfibers with erbium-ytterbium codoped silica sol-gel jackets. For a 4.5-cm-long coated microfiber, an internal gain of 1.8 dB and a net gain of 0.8 dB for a 1550 nm signal were observed, when combing together the gain of the doped jackets and low loss of microfibers. With benefits of convenience and versatility, this technique can be used for functionalizing microfibers with jackets showing gains in other spectral ranges, high nonlinearity, high sensitivity, and many other functions.

  5. Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems

    Science.gov (United States)

    Hagopian, John G.

    2010-01-01

    A technique was created to measure the pupil alignment of instruments in situ by measuring calibrated pupil alignment references (PARs) in instruments. The PAR can also be measured using an alignment telescope or an imaging system. PAR allows the verification of the science instrument (SI) pupil alignment at the integrated science instrument module (ISIM) level of assembly at ambient and cryogenic operating temperature. This will allow verification of the ISIM+SI alignment, and provide feedback to realign the SI if necessary.

  6. Advanced techniques for free-space optical quantum cryptography over water

    Science.gov (United States)

    Hill, Alexander D.; Christensen, Bradley; Kwiat, Paul G.

    2016-03-01

    Free-space quantum key distribution (QKD) over water (e.g., ship to ship) may be limited by ship motion and atmospheric effects, such as mode distortion and beam wander due to turbulence. We report on a technique which reduces noise by excluding spatial modes which are less likely to contain QKD signal photons and experimentally demonstrate an improvement in QKD key generation rates in various noise and turbulence regimes.

  7. Three-dimensional surface measurement based on the projected defocused pattern technique using imaging fiber optics

    Science.gov (United States)

    Parra Escamilla, Geliztle A.; Kobayashi, Fumio; Otani, Yukitoshi

    2017-05-01

    We present a three-dimensional surface measurement system using imaging fiber endoscope and the measurement is based on the focus technique in uniaxial configuration. The surface height variation of the sample is retrieved by taking into account the contrast modulation change obtained from a projected fringe pattern on the sample. The technique takes into account the defocus change of the fringe pattern due to the height variation of the sample and by a Gaussian fitting process the height reconstruction can be retrieved. A baseline signal procedure was implemented to remove back reflection light coming from the two fiber-surfaces (inlet and outlet) and also a Fourier transform filter was used to remove the pixelated appearance of the images. The depth range of the system is 1.1 mm and a lateral range of 2 mm by 2 mm. The novelties of the implementation are that the system uses the same imaging fiber as illumination and measurement and offers the advantage of the transportability to the measurement to a confined space having potential application on medical or industrial endoscopes systems. We demonstrate the technique by showing the surface profile of a measured object.

  8. Incipient fault diagnosis of power transformers using optical spectro-photometric technique

    Science.gov (United States)

    Hussain, K.; Karmakar, Subrata

    2015-06-01

    Power transformers are the vital equipment in the network of power generation, transmission and distribution. Mineral oil in oil-filled transformers plays very important role as far as electrical insulation for the winding and cooling of the transformer is concerned. As transformers are always under the influence of electrical and thermal stresses, incipient faults like partial discharge, sparking and arcing take place. As a result, mineral oil deteriorates there by premature failure of the transformer occurs causing huge losses in terms of revenue and assets. Therefore, the transformer health condition has to be monitored continuously. The Dissolved Gas Analysis (DGA) is being extensively used for this purpose, but it has some drawbacks like it needs carrier gas, regular instrument calibration, etc. To overcome these drawbacks, Ultraviolet (UV) -Visible and Fourier Transform Infrared (FTIR) Spectro-photometric techniques are used as diagnostic tools for investigating the degraded transformer oil affected by electrical, mechanical and thermal stresses. The technique has several advantages over the conventional DGA technique.

  9. A novel high-contrast imaging technique based on optical tunneling to search for faint companions around bright stars at the limit of diffraction

    CERN Document Server

    Derigs, Dominik; Ghosh, Dhriti Sundar; Abel-Tibérini, Laëtitia

    2016-01-01

    We present a novel application of optical tunneling in the context of high-angular resolution, high-contrast techniques with the aim of improving direct imaging capabilities of faint companions in the vicinity of bright stars. In contrast to existing techniques like coronagraphy, we apply well-established techniques from integrated optics to exclusively extinct a very narrow angular direction coming from the sky. This extinction is achieved in the pupil plane and does not suffer from diffraction pattern residuals. We give a comprehensive presentation of the underlying theory as well as first laboratory results.

  10. Progress of a cross-correlation based optical strain measurement technique for detecting radial growth on a rotating disk

    Science.gov (United States)

    Clem, Michelle M.; Woike, Mark R.; Abdul-Aziz, Ali

    2014-04-01

    The Aeronautical Sciences Project under NASA's Fundamental Aeronautics Program is interested in the development of novel measurement technologies, such as optical surface measurements for the in situ health monitoring of critical constituents of the internal flow path. In situ health monitoring has the potential to detect flaws, i.e. cracks in key components, such as engine turbine disks, before the flaws lead to catastrophic failure. The present study, aims to further validate and develop an optical strain measurement technique to measure the radial growth and strain field of an already cracked disk, mimicking the geometry of a sub-scale turbine engine disk, under loaded conditions in the NASA Glenn Research Center's High Precision Rotordynamics Laboratory. The technique offers potential fault detection by imaging an applied high-contrast random speckle pattern under unloaded and loaded conditions with a CCD camera. Spinning the cracked disk at high speeds (loaded conditions) induces an external load, resulting in a radial growth of the disk of approximately 50.0-μm in the flawed region and hence, a localized strain field. When imaging the cracked disk under static conditions, the disk will be undistorted; however, during rotation the cracked region will grow radially, thus causing the applied particle pattern to be `shifted'. The resulting particle displacements between the two images is measured using the two-dimensional cross-correlation algorithms implemented in standard Particle Image Velocimetry (PIV) software to track the disk growth, which facilitates calculation of the localized strain field. A random particle distribution is adhered onto the surface of the cracked disk and two bench top experiments are carried out to evaluate the technique's ability to measure the induced particle displacements. The disk is shifted manually using a translation stage equipped with a fine micrometer and a hotplate is used to induce thermal growth of the disk, causing the

  11. A New Application of A Fiber Optic Technique In Magnetic Borehole Logging

    Science.gov (United States)

    Stoll, J. B.; Leven, M.; Steveling, E.; Shipboard Party Leg 197, Odp

    A borehole magnetometer from the Institute of Geophysics, University of Goettingen, Germany, was employed in Hole 1203A on Detroit Seamount. The tool consists of three fluxgate sensors which log the two horizontal (X, Y) and the vertical (Z) compo- nent of the magnetic flux density at depth. For the first time, a fiber optic angular rate sensor was employed in a borehole tool to measure the rotation history during a log run. This rate sensor is an unconventional gyro since it does not have a spinning wheel. It has a small volume, low weight and requires only little power (2VA). Free from the effects of gravity-induced errors, and with no moving parts, this sensor is insensitive to shock and vibration. It detects and measures angular rates by measuring the fre- quency difference between two contra-rotating light beams. These travel through a fiber coil 110 m in length to a detector, which converts the light into an output signal for the electronics. A magnetic log was run in Hole 1203A on Detroit seamount from the rig floor to the total depth at 925 mbsf. For the first time the angular rate about the vertical spin axis was measured using the fiber optic gyro in combination with flux- gate sensors. The rotation history of the tool is determined by the accumulation of the rate during a log run. Before starting the log run the magnetic components of the tool were aligned to the ship axis on the rig floor. In Hole 1203A the tool rotated almost 60 times about its vertical body axis between the rig floor and the bottom of the hole. On its run back to the floor the tool followed nearly the same rotation history as on the downward run. After the tool was returned to the rig floor, it was aligned again to double check the orientation with the initial orientation. This check enabled changes in the heading of the ship and the Earth's rotation, which also affects the angular rate, to be taken into account. Preliminary results indicate that the difference between the initial and

  12. Automatic irradiation control by an optical feedback technique for selective retina treatment (SRT) in a rabbit model

    Science.gov (United States)

    Seifert, Eric; Roh, Young-Jung; Fritz, Andreas; Park, Young Gun; Kang, Seungbum; Theisen-Kunde, Dirk; Brinkmann, Ralf

    2013-06-01

    Selective Retina Therapy (SRT) targets the Retinal Pigment Epithelium (RPE) without effecting neighboring layers as the photoreceptors or the choroid. SRT related RPE defects are ophthalmoscopically invisible. Owing to this invisibility and the variation of the threshold radiant exposure for RPE damage the treating physician does not know whether the treatment was successful or not. Thus measurement techniques enabling a correct dosing are a demanded element in SRT devices. The acquired signal can be used for monitoring or automatic irradiation control. Existing monitoring techniques are based on the detection of micro-bubbles. These bubbles are the origin of RPE cell damage for pulse durations in the ns and μs time regime 5μs. The detection can be performed by optical or acoustical approaches. Monitoring based on an acoustical approach has already been used to study the beneficial effects of SRT on diabetic macula edema and central serous retinopathy. We have developed a first real time feedback technique able to detect micro-bubble induced characteristics in the backscattered laser light fast enough to cease the laser irradiation within a burst. Therefore the laser energy within a burst of at most 30 pulses is increased linearly with every pulse. The laser irradiation is ceased as soon as micro-bubbles are detected. With this automatic approach it was possible to observe invisible lesions, an intact photoreceptor layer and a reconstruction of the RPE within one week.

  13. Detection of aqueous glucose based on a cavity size- and optical-wavelength-independent continuous-wave photoacoustic technique.

    Science.gov (United States)

    Camou, S; Haga, T; Tajima, T; Tamechika, E

    2012-06-01

    Toward the achievement of noninvasive and continuous monitoring of blood glucose level, we developed a new measurement method based on the continuous-wave photoacoustic (CW-PA) technique and performed the first validation in vitro with calibrated aqueous glucose solutions. The PA technique has been studied in the past but exclusively based on the pulse setup since the CW one exhibits dependence on the cavity dimensions, which is not compatible with the final application requirements. This paper describes a new strategy relying on the monitoring of the resonant-frequency relative shift induced by the change of glucose concentrations rather than amplitude signal levels at a fixed frequency. From in vitro results, we demonstrate a stable and reproducible response to glucose at various cavity dimensions and optical wavelengths, with a slope of 0.19 ±0.01%/g/dL. From theoretical considerations, this method is consistent with a relative acoustic velocity measurement, which also explains the aforementioned stability. The proposed method then resolves most of the issues usually associated with the CW-PA technique and makes it a potential alternative for the noninvasive and continuous monitoring of glycemia levels. However, experimental determination of sensor responses to albumin and temperature as two potential interferents shows similar levels, which points to the selectivity to glucose as a major issue we should deal with in future development.

  14. Yangon River Geomorphology Identification and its Enviromental Imapacts Analsysi by Optical and Radar Sensing Techniques

    Science.gov (United States)

    Lwin, A.; Khaing, M. M.

    2012-07-01

    The Yangon river, also known as the Rangoon river, is about 40 km long (25miles), and flows from southern Myanmar as an outlet of the Irrawaddy (Ayeyarwady) river into the Ayeyarwady delta. The Yangon river drains the Pegu Mountains; both the Yangon and the Pathein rivers enter the Ayeyarwady at the delta. Fluvial geomorphology is based primarily on rivers of manageable dimensions. The emphasis is on geomorphology, sedimentology of Yangon river and techniques for their identification and management. Present techniques such as remote sensing have made it easier to investigate and interpret in details analysis of river geomorphology. In this paper, attempt has been made the complicated issues of geomorphology, sedimentation patterns and management of river system and evolution studied. The analysis was carried out for the impact of land use/ land cover (LULC) changes on stream flow patterns. The hydrologic response to intense, flood producing rainfall events bears the signatures of the geomorphic structure of the channel network and of the characteristic slope lengths defining the drainage density of the basin. The interpretation of the hydrologic response as the travel time distribution of a water particle randomly injected in a distributed manner across the landscape inspired many geomorphic insights. In 2008, Cyclone Nargis was seriously damaged to mangrove area and its biodiversity system in and around of Yangon river terraces. A combination of digital image processing techniques was employed for enhancement and classification process. It is observed from the study that middle infra red band (0.77mm - 0.86mm) is highly suitable for mapping mangroves. Two major classes of mangroves, dense and open mangroves were delineated from the digital data.

  15. Comprehensive Assessment of New Modulation Techniques in 40 Gb/s Optical Communication Systems

    Energy Technology Data Exchange (ETDEWEB)

    Bing Linlin; Lei Jianming; Lu Li; Zou Xuecheng, E-mail: leijianming@mail.hust.edu.cn [Research Center for VLSI and Systems, Department of Electronic Science and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2011-02-01

    In this paper, comprehensive assessments are proposed for intensity modulations and phase modulations respectively. Several key performance features, like receiver sensitivity, chromatic dispersion tolerance, nonlinearity tolerance, and noise sensitivity were compared among these modulation techniques. Results show that 66% duty cycle RZ signal so-called the carrier-suppressed return-to-zero (CSRZ) format has the best performance in the intensity modulations. In phase modulations, the most outstanding modulation is DPSK. DQPSK modulation is also a very promising choice if the effect of noise could be resolved. The combination of intensity modulation and phase modulation will compromise the performance advantages of both.

  16. Study of optical techniques for the Ames unitary wind tunnels. Part 4: Model deformation

    Science.gov (United States)

    Lee, George

    1992-01-01

    A survey of systems capable of model deformation measurements was conducted. The survey included stereo-cameras, scanners, and digitizers. Moire, holographic, and heterodyne interferometry techniques were also looked at. Stereo-cameras with passive or active targets are currently being deployed for model deformation measurements at NASA Ames and LaRC, Boeing, and ONERA. Scanners and digitizers are widely used in robotics, motion analysis, medicine, etc., and some of the scanner and digitizers can meet the model deformation requirements. Commercial stereo-cameras, scanners, and digitizers are being improved in accuracy, reliability, and ease of operation. A number of new systems are coming onto the market.

  17. Multimodal imaging of the human temporal bone: A comparison of CT and optical scanning techniques

    Science.gov (United States)

    Voie, Arne H.; Whiting, Bruce; Skinner, Margaret; Neely, J. Gail; Lee, Kenneth; Holden, Tim; Brunsden, Barry

    2003-10-01

    A collaborative effort between Washington University in St. Louis and Spencer Technologies in Seattle, WA has been undertaken to create a multimodal 3D reconstruction of the human cochlea and vestibular system. The goal of this project is to improve the accuracy of in vivo CT reconstructions of implanted cochleae, and to expand the knowledge of high-resolution anatomical detail provided by orthogonal-plane optical sectioning (OPFOS). At WUSL, computed tomography (CT) images of the cochlea are used to determine the position of cochlear implant electrodes relative to target auditory neurons. The cochlear implant position is determined using pre- and post-operative CT scans. The CT volumes are cross-registered to align the semicircular canals and internal auditory canal, which have a unique configuration in 3-D space. The head of a human body donor was scanned with a clinical CT device, after which the temporal bones were removed, fixed in formalin and trimmed prior to scanning with a laboratory Micro CT scanner. Following CT, the temporal bones were sent to the OPFOS Imaging Lab at Spencer Technologies for a further analysis. 3-D reconstructions of CT and OPFOS imaging modalities were compared, and results are presented. [Work supported by NIDCD Grants R44-03623-5 and R01-00581-13.

  18. Visualization techniques with the aid of optical Schlieren system; Schlieren kashika gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Higashino, F. [Tokyo Univ. of Agriculture and Technology, Tokyo (Japan). Faculty of Technology

    1999-11-05

    Outlined herein is the Schlieren method as one of the most common methods for visualizing high-speed compressible flows. It follows density gradients, and particularly suitable for strong shock waves. An illuminance image is produced by shielding, with the aid of an optical knife edge, light ray deflected by a density gradient in a medium. It is important to adjust knife edge position with illuminance. A concave mirror is a common choice for lens. The common light sources include halogen lamp and, more recently, pulse laser. For example, a pulse laser is suitable for, e.g., propagating shock wave planes and light-emitting combustion, and mercury lamp and Ar laser for slow flows. Some of the visualizing applications are color photographing with the aid of a color filter or the like, where refracted continuous spectral light, changed by density gradient, is used as changed hue; observation of birefringence-caused interference fringes by placing a polarizer and light sensor on the first and second focuses; and visualization of shock waves in a supersonic nozzle and shear layer distribution. (NEDO)

  19. Linking optical and electrical small amplitude perturbation techniques for dynamic performance characterization of dye solar cells.

    Science.gov (United States)

    Halme, Janne

    2011-07-21

    This paper unifies the analytical models used widely but thus far mostly separately for electrical and optical small amplitude perturbation measurements of nanostructured electrochemical dye solar cells (DSC): electrochemical impedance spectroscopy (EIS), intensity-modulated photocurrent spectroscopy (IMPS) and intensity-modulated photovoltage spectroscopy (IMVS). The models are linked by expressing the kinetic boundary condition used for solving the time-dependent continuity equation of electrons in IMPS and IMVS analysis in terms of the series and parallel impedance components found in the complete equivalent circuit impedance model of DSC. As a result, analytical expressions are derived for potentiostatic IMPS and galvanostatic IMVS transfer functions of complete DSCs that are applicable at any operating point along the solar cell current-voltage (IV) curve. In agreement with the theory, impedance spectrum calculated as a ratio of IMVS and IMPS transfer functions measured near the maximum power point matches exactly with the impedance spectrum measured directly with EIS. Consequently, both IMPS-IMVS and EIS yield equal estimates for the electron diffusion length. The role of the chemical capacitance of the nanostructured semiconductor photoelectrode in the interpretation of the so-called RC attenuation of the IMPS response is clarified, as well as the capacitive frequency dispersion in IMPS and IMVS. This journal is © the Owner Societies 2011

  20. Optimization of the sinusoidal phase modulation technique in resonant fiber optic gyro

    Science.gov (United States)

    Wang, Linglan; Li, Hanzhao; Zhang, Jianjie; Ma, Huilian; Jin, Zhonghe

    2017-03-01

    The sinusoidal wave phase modulation and demodulation have been widely used in the signal processing system of the resonant fiber optic gyro (RFOG). An appropriate selection of the modulation frequency is of great importance, for the frequency value directly affects the slope of the demodulation curve at the resonance point which carries the gyro output information. A large demodulation slope is pursued in a high-performance RFOG. In this paper, an analytical expression of the demodulation slope is for the first time deduced in both transmission-type and reflection-type fiber ring resonators without any approximation. The relationship between the slope value and the modulation frequency at the resonance point is accurately calculated. The calculated best modulation frequency maximizing the demodulation slope at the resonance point is different from previous widely used optimal frequency given by the Lorentzian approximation method. More importantly, both theoretical and experimental results indicate that the achieved maximal demodulation slope from the proposed analytical expression method is double of that obtaining from the Lorentzian approximation method.

  1. [Rapid discriminating hogwash oil and edible vegetable oil using near infrared optical fiber spectrometer technique].

    Science.gov (United States)

    Zhang, Bing-Fang; Yuan, Li-Bo; Kong, Qing-Ming; Shen, Wei-Zheng; Zhang, Bing-Xiu; Liu, Cheng-Hai

    2014-10-01

    In the present study, a new method using near infrared spectroscopy combined with optical fiber sensing technology was applied to the analysis of hogwash oil in blended oil. The 50 samples were a blend of frying oil and "nine three" soybean oil according to a certain volume ratio. The near infrared transmission spectroscopies were collected and the quantitative analysis model of frying oil was established by partial least squares (PLS) and BP artificial neural network The coefficients of determina- tion of calibration sets were 0.908 and 0.934 respectively. The coefficients of determination of validation sets were 0.961 and 0.952, the root mean square error of calibrations (RMSEC) was 0.184 and 0.136, and the root mean square error of predictions (RMSEP) was all 0.111 6. They conform to the model application requirement. At the same time, frying oil and qualified edible oil were identified with the principal component analysis (PCA), and the accurate rate was 100%. The experiment proved that near infrared spectral technology not only can quickly and accurately identify hogwash oil, but also can quantitatively detect hog- wash oil. This method has a wide application prospect in the detection of oil.

  2. Revealing t-tubules in striated muscle with new optical super-resolution microscopy techniques

    Directory of Open Access Journals (Sweden)

    Isuru D. Jayasinghe

    2014-12-01

    Full Text Available The t-tubular system plays a central role in the synchronisation of calcium signalling and excitation-contraction coupling in most striated muscle cells. Light microscopy has been used for imaging t-tubules for well over 100 years and together with electron microscopy (EM, has revealed the three-dimensional complexities of the t-system topology within cardiomyocytes and skeletal muscle fibres from a range of species. The emerging super-resolution single molecule localisation microscopy (SMLM techniques are offering a near 10-fold improvement over the resolution of conventional fluorescence light microscopy methods, with the ability to spectrally resolve nanometre scale distributions of multiple molecular targets. In conjunction with the next generation of electron microscopy, SMLM has allowed the visualisation and quantification of intricate t-tubule morphologies within large areas of muscle cells at an unprecedented level of detail. In this paper, we review recent advancements in the t-tubule structural biology with the utility of various microscopy techniques. We outline the technical considerations in adapting SMLM to study t-tubules and its potential to further our understanding of the molecular processes that underlie the sub-micron scale structural alterations observed in a range of muscle pathologies.

  3. An indoor test campaign of the tomography long path differential optical absorption spectroscopy technique.

    Science.gov (United States)

    Mettendorf, K U; Hartl, A; Pundt, I

    2006-02-01

    In this study we validate the two-dimensional long path DOAS tomography measurement technique by means of an indoor experiment with well-known concentration distributions. The experiment was conducted over an area of 10 m x 15 m using one and two cylindrical polycarbonate containers of diameter 2 m, respectively, filled with NO2. The setup was realized with three of the multibeam instruments recently developed by Pundt and Mettendorf (Appl. Opt., 2005, in press), which allow the simultaneous measurement along at least four light paths each. The configuration consisted of twelve simultaneous light beams, 39 horizontal light paths in total, and 18 different cylinder positions inside the field. It was found that for the discretization and inversion technique shown here reconstructions of the concentration distributions from experimental data agree well with simulated reconstructions. In order to draw conclusions for atmospheric applications, numerical studies including instrumental errors were carried out. It was found that with the presented measurement setup it is possible to measure and reconstruct one or two NO2 plumes of 600 m diameter and average concentrations above 4.2 ppbv each, on a scale of 13.5 km2. Theoretical investigations show that it should be possible to localize and quantify 600 m diameter plumes of SO2 > 1.5 ppbv, H2CO > 6.3 ppbv, HONO > 3.2 ppbv, and ozone > 46.2 ppbv. Larger plumes can be measured with higher precision.

  4. Deriving the electron-phonon spectral density of MgB2 from optical data, using maximum entropy techniques.

    Science.gov (United States)

    Hwang, J; Carbotte, J P

    2014-04-23

    We use maximum entropy techniques to extract an electron-phonon density from optical data for the normal state at T = 45 K of MgB2. Limiting the analysis to a range of phonon energies below 110 meV, which is sufficient for capturing all phonon structures, we find a spectral function that is in good agreement with that calculated for the quasi-two-dimensional σ-band. Extending the analysis to higher energies, up to 160 meV, we find no evidence for any additional contributions to the fluctuation spectrum, but find that the data can only be understood if the density of states is taken to decrease with increasing energy.

  5. The effect of radiation damage on optical and scintillation properties of BGO crystals grown by the LTG Cz technique

    CERN Document Server

    Gusev, V A; Kupriyanov, I N; Kuznecov, G N; Shlegel, V N; Antsygin, V D; Vasiliev, Y V

    2002-01-01

    BGO crystals grown by the low-thermal-gradient Czochralski technique (LTG Cz) exhibit two distinct types of behavior upon radiation damage and recovery. The crystals termed as of L-type remain colorless after gamma-radiation doses as high as 10 Mrad. As the irradiation dose increases the scintillation light output shows a weak monotonous degradation to 15-25%, saturating at around several hundreds krad doses. The crystals termed as of N-type attain yellow coloration after irradiation. The light output drops abruptly for 35-50% as early as after 1 krad and does not change further on. The present work is devoted to the study of radiation damage effects, self-recovery, optically stimulated recovery and thermo-stimulated current in the L- and N-type BGO crystals produced by LTG Cz.

  6. Optical-flow-based background-oriented schlieren technique for measuring a laser-induced underwater shock wave

    CERN Document Server

    Hayasaka, Keisuke; Liu, Tianshu; Kameda, Masaharu

    2016-01-01

    The background-oriented schlieren (BOS) technique with the physics-based optical flow method (OF-BOS) is developed for measuring the pressure field of a laser-induced underwater shock wave. Compared to BOS with the conventional cross-correlation method in PIV (called PIV-BOS), by using the OF-BOS, the displacement field generated by the small density gradient in water can be obtained at the spatial resolution of one vector per pixel. The corresponding density and pressure fields can be further extracted. It is particularly demonstrated that the sufficiently high spatial resolution of the extracted displacement vector field is required in the tomographic reconstruction to correctly infer the pressure field of the spherical underwater shock wave. The capability of the OF-BOS is critically evaluated based on synchronized hydrophone measurements. Special emphasis is placed on direct comparison between the OF-BOS with the PIV-BOS.

  7. Optical-flow-based background-oriented schlieren technique for measuring a laser-induced underwater shock wave

    Science.gov (United States)

    Hayasaka, Keisuke; Tagawa, Yoshiyuki; Liu, Tianshu; Kameda, Masaharu

    2016-12-01

    The background-oriented schlieren (BOS) technique with the physics-based optical flow method (OF-BOS) is developed for measuring the pressure field of a laser-induced underwater shock wave. Compared to BOS with the conventional cross-correlation method that is also applied for particle image velocimetry (here called PIV-BOS), by using the OF-BOS, the displacement field generated by a small density gradient in water can be obtained at the spatial resolution of one vector per pixel. The corresponding density and pressure fields can be further extracted. It is demonstrated in particular that the sufficiently high spatial resolution of the extracted displacement vector field is required in the tomographic reconstruction to correctly infer the pressure field of the spherical underwater shock wave. The capability of the OF-BOS method is critically evaluated based on synchronized hydrophone measurements. Special emphasis is placed on direct comparison between the OF-BOS and PIV-BOS methods.

  8. Portable optical frequency standard based on sealed gas-filled hollow-core fiber using a novel encapsulation technique

    DEFF Research Database (Denmark)

    Triches, Marco; Brusch, Anders; Hald, Jan

    2015-01-01

    A portable stand-alone optical frequency standard based on a gas-filled hollow-core photonic crystal fiber is developed to stabilize a fiber laser to the 13C2H2 P(16) (ν1 + ν3) transition at 1542 nm using saturated absorption. A novel encapsulation technique is developed to permanently seal...... the hollow-core fiber with easy light coupling, showing negligible pressure increase over two months. The locked laser shows a fractional frequency instability below 8 × 10−12 for an averaging time up to 104 s. The lock-point repeatability over one month is 2.6 × 10−11, corresponding to a standard deviation...

  9. Optical and Surface Characteristics of Mg-Doped GaAs Nanocrystalline Thin Film Deposited by Thermionic Vacuum Arc Technique

    Science.gov (United States)

    Pat, Suat; Özen, Soner; Şenay, Volkan; Korkmaz, Şadan

    2017-01-01

    Magnesium (Mg) is the most promising p-type dopant for gallium arsenide (GaAs) semiconductor technology. Mg-doped GaAs nanocrystalline thin film has been deposited at room temperature by the thermionic vacuum arc technique, a rapid deposition method for production of doped GaAs material. The microstructure and surface and optical properties of the deposited sample were investigated by x-ray diffraction analysis, scanning electron microscopy, energy-dispersive x-ray spectroscopy, atomic force microscopy, ultraviolet-visible spectrophotometry, and interferometry. The crystalline direction of the deposited sample was determined to be (220) plane and (331) plane at 44.53° and 72.30°, respectively. The Mg-doped GaAs nanocrystalline sample showed high transmittance.

  10. Nonlinear optical processes at quadrupole polariton resonance in Cu2O as probed by a Z-scan technique

    Science.gov (United States)

    Mani, S.; Jang, J. I.; Ketterson, J. B.

    2010-09-01

    Employing a modified Z-scan technique at 2 K, we monitor not only the fundamental (ω) but also the frequency-doubled (2ω) and tripled (3ω) Z-scan responses in Cu2O when the input laser frequency ω is tuned to the two-photon quadrupole polariton resonance. The Z-scan response at ω allows us to accurately estimate the absolute number of polaritons generated via two-photon absorption. A striking dip is observed near the 2ω Z-scan focus which basically arises from Auger-type recombination of polaritons. Under high excitation levels, the 3ω Z-scan shows strong third harmonic generation. Based on the nonlinear optical parameters determined, we estimate the experimental polariton density achievable and propose a direction for polariton-based Bose-Einstein condensation in Cu2O .

  11. Effect of Low Concentration Sn Doping on Optical Properties of CdS Films Grown by CBD Technique

    Directory of Open Access Journals (Sweden)

    Mohd Sabri Mohd Ghazali

    2011-09-01

    Full Text Available Thin and transparent films of doped cadmium sulfide (CdS were obtained on commercial glass substrates by Chemical Bath Deposition (CBD technique. The films were doped with low concentration of Sn, and annealed in air at 300 °C for 45 min. The morphological characterization of the films with different amounts of dopant was made using SEM and EDAX analysis. Optical properties of the films were evaluated by measuring transmittance using the UV-vis spectrophotometer. A comparison of the results revealed that lower concentration of Sn doping improves transmittance of CdS films and makes them suitable for application as window layer of CdTe/CIGS solar cells.

  12. Modification of the morphology and optical properties of SnS films using glancing angle deposition technique

    Science.gov (United States)

    Sazideh, M. R.; Dizaji, H. Rezagholipour; Ehsani, M. H.; Moghadam, R. Zarei

    2017-05-01

    Tin sulfide (SnS) films were prepared by thermal evaporation method using Glancing Angle Deposition (GLAD) technique at zero and different oblique incident flux angles (α = 45°, 55°, 65°, 75° and 85°). The physical properties of prepared films were systematically investigated. The X-ray diffraction analysis indicated that the film deposited at α = 0° formed as single phase with an orthorhombic structure. However, the layers became amorphous at α = 45°, 55°, 65°, 75° and 85°. Beside the appearance of amorphous feature in the film prepared at α higher than zero, Sn2S3 phase was also observed. The top and cross-sectional field emission scanning electron microscope (FESEM) images of the samples showed noticeable changes in the structure and morphology of individual nano-plates as a function of incident angle. The band gap and refractive index values of the films were calculated by optical transmission measurements. The optical band-gap values were observed to increase with increasing the incident flux angle. This can be due to presence of Sn2S3 phase observed in the samples produced at α values other than zero. The effective refractive index and porosity exhibit an opposite evolution as the incident angle α rises. At α = 85° the layers show a considerable change in effective refractive index (Δn = 1.7) at near-IR spectral range.

  13. Characterization of RF He-N2/Ar mixture plasma via Langmuir probe and optical emission spectroscopy techniques

    Science.gov (United States)

    Younus, Maria; Rehman, N. U.; Shafiq, M.; Hussain, S. S.; Zakaullah, M.; Zaka-ul-Islam, M.

    2016-08-01

    A Magnetic Pole Enhanced inductively coupled RF H e - N 2 / A r plasma is characterized using a Langmuir probe and optical emission spectroscopy (OES) techniques. The effect of helium mixing on electron density ( n e ) and temperature ( T e ) , electron energy probability functions (EEPFs), [ N ] atomic density, and N 2 dissociation is investigated. A Langmuir probe and a zero slope method based on trace rare gas-optical emission spectroscopy (TRG-OES) are employed to measure the electron temperature. It is noted that the electron temperature shows an increasing trend for both methods. However, the temperature measured by a zero slope method T e ( Z . S ) approaches the temperature measured by a Langmuir probe; T e ( L . P ) at 56% and above helium concentration in the discharge. "Advance actinometry" is employed to monitor the variation in [ N ] atomic density with helium concentration and gas pressure. It is noted that [ N ] atomic density increases at 56% and above helium in the discharge, which is consistent with the trend of electron temperature and EEPFs. A drastic enhancement in N 2 dissociation fraction D 1 determined by "advance actinometry" is noted at 56% and above helium concentration in the mixture due to modifications in different population and depopulation mechanisms. However, it is also noted that the dissociation fraction D 2 determined by intensity ratio method increases linearly with helium addition.

  14. Optical and electrical properties of ZrSe3 single crystals grown by chemical vapour transport technique

    Indian Academy of Sciences (India)

    Kaushik Patel; Jagdish Prajapati; Rajiv Vaidya; S G Patel

    2005-08-01

    Single crystals of the lamellar compound, ZrSe3, were grown by chemical vapour transport technique using iodine as a transporting agent. The grown crystals were characterized with the help of energy dispersive analysis by X-ray (EDAX), which gave confirmation about the stoichiometry. The optical band gap measurement of as grown crystals was carried out with the help of optical absorption spectra in the range 700–1450 nm. The indirect as well as direct band gap of ZrSe3 were found to be 1.1 eV and 1.47 eV, respectively. The resistivity of the as grown crystals was measured using van der Pauw method. The Hall parameters of the grown crystals were determined at room temperature from Hall effect measurements. Electrical resistivity measurements were performed on this crystal in the temperature range 303–423 K. The crystals were found to exhibit semiconducting nature in this range. The activation energy and anisotropy measurements were carried out for this crystal. Pressure dependence of electrical resistance was studied using Bridgman opposed anvils set up up to 8 GPa. The semiconducting nature of ZrSe3 single crystal was inferred from the graph of resistance vs pressure. The results obtained are discussed in detail.

  15. Structural and optical properties of LiKB{sub 4}O{sub 7} single crystals grown by Czochralski technique

    Energy Technology Data Exchange (ETDEWEB)

    Sukumar, M. [Crystal Growth and Thin Film Laboratory, Department of Physics, Bharathidasan University, Tiruchirappalli 620 024, Tamil Nadu (India); Babu, R. Ramesh, E-mail: rampap2k@yahoo.co.in [Crystal Growth and Thin Film Laboratory, Department of Physics, Bharathidasan University, Tiruchirappalli 620 024, Tamil Nadu (India); Ramamurthi, K. [Crystal Growth and Thin Film Laboratory, Department of Physics and Nanotechnology, Faculty of Engineering and Technology, SRM University, Kattankulathur 603 203, Tamil Nadu (India); Bhagavannarayana, G. [Crystal Growth and Crystallography Section, National Physical Laboratory, Krishnan Marg, New Delhi 110 012 (India)

    2015-06-15

    One of the alkali metal borates, lithium potassium borate (LiKB{sub 4}O{sub 7}) single crystal, was grown following two different micro step pulling movements employing the modified crystal puller. The influence of two different micro step pulling movements on the crystalline nature, optical properties and micro morphology of the grown LiKB{sub 4}O{sub 7} crystal was investigated by high resolution X-ray diffraction (HRXRD) analysis and birefringence interferometry and chemical etching techniques, respectively. HRXRD studies revealed that the crystalline perfection of the grown crystals is reasonably good. Interferometric images showed that the crystal grown under higher micro step pulling movement has very less number of scattering centers. The etching studies revealed that the crystal grown under higher micro steps pulling movement contains relatively low level dislocation density. - Graphical abstract: Diffraction curve recorded for LiKB{sub 4}O{sub 7} crystal from (a) top portion and (b) bottom portion. - Highlights: • LiKB{sub 4}O{sub 7} crystal was grown under two different micro stepping movements by the crystal puller. • Crystalline nature, optical properties and micro morphology of LiKB{sub 4}O{sub 7} were investigated. • The micro stepping pull movement reduces the dislocation density during the growth of LiKB{sub 4}O{sub 7} crystals.

  16. Structure, optical and electrical properties of indium tin oxide ultra thin films prepared by jet nebulizer spray pyrolysis technique

    Directory of Open Access Journals (Sweden)

    M. Thirumoorthi

    2016-03-01

    Full Text Available Indium tin oxide (ITO thin films have been prepared by jet nebulizer spray pyrolysis technique for different Sn concentrations on glass substrates. X-ray diffraction patterns reveal that all the films are polycrystalline of cubic structure with preferentially oriented along (222 plane. SEM images show that films exhibit uniform surface morphology with well-defined spherical particles. The EDX spectrum confirms the presence of In, Sn and O elements in prepared films. AFM result indicates that the surface roughness of the films is reduced as Sn doping. The optical transmittance of ITO thin films is improved from 77% to 87% in visible region and optical band gap is increased from 3.59 to 4.07 eV. Photoluminescence spectra show mainly three emissions peaks (UV, blue and green and a shift observed in UV emission peak. The presence of functional groups and chemical bonding was analyzed by FTIR. Hall effect measurements show prepared films having n-type conductivity with low resistivity (3.9 × 10−4 Ω-cm and high carrier concentrations (6.1 × 1020 cm−3.

  17. Development and Experimental Testing of an Optical Micro-Spectroscopic Technique Incorporating True Line-Scan Excitation

    Directory of Open Access Journals (Sweden)

    Gabriel Biener

    2013-12-01

    Full Text Available Multiphoton micro-spectroscopy, employing diffraction optics and electron-multiplying CCD (EMCCD cameras, is a suitable method for determining protein complex stoichiometry, quaternary structure, and spatial distribution in living cells using Förster resonance energy transfer (FRET imaging. The method provides highly resolved spectra of molecules or molecular complexes at each image pixel, and it does so on a timescale shorter than that of molecular diffusion, which scrambles the spectral information. Acquisition of an entire spectrally resolved image, however, is slower than that of broad-bandwidth microscopes because it takes longer times to collect the same number of photons at each emission wavelength as in a broad bandwidth. Here, we demonstrate an optical micro-spectroscopic scheme that employs a laser beam shaped into a line to excite in parallel multiple sample voxels. The method presents dramatically increased sensitivity and/or acquisition speed and, at the same time, has excellent spatial and spectral resolution, similar to point-scan configurations. When applied to FRET imaging using an oligomeric FRET construct expressed in living cells and consisting of a FRET acceptor linked to three donors, the technique based on line-shaped excitation provides higher accuracy compared to the point-scan approach, and it reduces artifacts caused by photobleaching and other undesired photophysical effects.

  18. Energy-efficient optical network units for OFDM PON based on time-domain interleaved OFDM technique.

    Science.gov (United States)

    Hu, Xiaofeng; Cao, Pan; Zhang, Liang; Jiang, Lipeng; Su, Yikai

    2014-06-02

    We propose and experimentally demonstrate a new scheme to reduce the energy consumption of optical network units (ONUs) in orthogonal frequency division multiplexing passive optical networks (OFDM PONs) by using time-domain interleaved OFDM (TI-OFDM) technique. In a conventional OFDM PON, each ONU has to process the complete downstream broadcast OFDM signal with a high sampling rate and a large FFT size to retrieve its required data, even if it employs a portion of OFDM subcarriers. However, in our scheme, the ONU only needs to sample and process one data group from the downlink TI-OFDM signal, effectively reducing the sampling rate and the FFT size of the ONU. Thus, the energy efficiency of ONUs in OFDM PONs can be greatly improved. A proof-of-concept experiment is conducted to verify the feasibility of the proposed scheme. Compared to the conventional OFDM PON, our proposal can save 17.1% and 26.7% energy consumption of ONUs by halving and quartering the sampling rate and the FFT size of ONUs with the use of the TI-OFDM technology.

  19. Optically stimulated luminescence techniques in retrospective dosimetry using single grains of quartz extracted from unheated materials

    Energy Technology Data Exchange (ETDEWEB)

    Joerkov Thomsen, Kristina

    2004-02-01

    This work investigates the possibility of applying optically stimulated luminescence (OSL) in retrospective dose determinations using unheated materials. It focuses on identifying materials suitable for use in assessment of doses absorbed as a consequence of radiation accidents (i.e. accident dosimetry). Special attention has been paid to quartz extracted from unheated building materials such as concrete and mortar. The single-aliquot regeneration-dose (SAR) protocol has been used to determine absorbed doses in small aliquots as well as single grains of quartz. It is shown that OSL measurements of single grains of quartz extracted from poorly-bleached building materials can provide useful information on radiation accident doses, even when the luminescence sensitivity is low. Sources of variance in well-bleached single grain dose distributions have been investigated in detail and it is concluded that the observed variability in the data is consistent with the sum (in quadrature) of a component, which depends on the number of photons detected from each grain, and a fixed component independent of light level. Dose depth profiles through laboratory irradiated concrete bricks have successfully been measured and minimum detection limits of less than 100 mGy are derived. Measurements of thermal transfer in single grains of poorly-bleached quartz show that thermal transfer is variable on a grain-to-grain basis and that it can be a source of variance in single-grain dose distributions. Furthermore, the potential of using common household and workplace chemicals, such as table salt, washing powder and water softener, in retrospective dosimetry has been investigated. It is concluded that such materials should be considered as retrospective dosimeters in the event of a radiation accident. (au)

  20. Investigation of optical band gap and device parameters of rubrene thin film prepared using spin coating technique

    Energy Technology Data Exchange (ETDEWEB)

    Tuğluoğlu, Nihat, E-mail: tugluo@gmail.com [Department of Technology, Sarayköy Nuclear Research and Training Center, 06983 Saray, Ankara (Turkey); Barış, Behzad; Gürel, Hatice [Department of Physics, Faculty of Arts and Sciences, Giresun University, Gazipaşa Campus, Giresun 28100 (Turkey); Karadeniz, Serdar [Department of Technology, Sarayköy Nuclear Research and Training Center, 06983 Saray, Ankara (Turkey); Yüksel, Ömer Faruk [Department of Physics, Faculty of Science, Selçuk University, Campus Konya 42075 (Turkey)

    2014-01-05

    Highlights: • Thin film of rubrene has been deposited by spin coating technique. • The band gap properties of the film were investigated in the range 200–700 nm. • The analysis of the absorption coefficient revealed indirect allowed transition. • The parameters such as barrier height and ideality factor were determined. -- Abstract: Rubrene thin film has been deposited by spin coating technique. The optical band gap properties of rubrene thin film have been investigated in the spectral range 200–700 nm. The results of the absorption coefficient (α) were analyzed in order to determine the optical band gap and Urbach energy of the film. The absorption spectra recorded in the UV–vis region shows two peaks at 250 nm and 300 nm. The analysis of the spectral behavior of the absorption coefficient (α) in the absorption region revealed indirect allowed transition with corresponding energy 2.31 eV. The value of Urbach energy (E{sub U}) was determined to be 1.169 eV. The current–voltage (I–V) characteristics and electrical conduction properties of rubrene/n-Si device fabricated by spin coating method have also been investigated. The I–V characteristic in dark was showed the rectification effect due to the formation of Schottky barrier at rubrene/silicon interface. From analyzing the I-V measurement for the device, the basic device parameters such as barrier height, ideality factor and series resistance were determined. At the low-voltage region, the current conduction in Au/rubrene/n-Si device is ohmic type. The charge transport phenomenon appears to be space charge limited current (SCLC) at higher-voltage regions.