  1. Reactor operations Brookhaven medical research reactor, Brookhaven high flux beam reactor informal monthly report

    International Nuclear Information System (INIS)

    Hauptman, H.M.; Petro, J.N.; Jacobi, O.

    1995-04-01

    This document is the April 1995 summary report on reactor operations at the Brookhaven Medical Research Reactor and the Brookhaven High Flux Beam Reactor. Ongoing experiments/irradiations in each are listed, and other significant operations functions are also noted. The HFBR surveillance testing schedule is also listed

  2. Brookhaven highlights - Brookhaven National Laboratory 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    This report highlights research conducted at Brookhaven National Laboratory in the following areas: alternating gradient synchrotron; physics; biology; national synchrotron light source; department of applied science; medical; chemistry; department of advanced technology; reactor; safety and environmental protection; instrumentation; and computing and communications.

  3. How Big Science Came to Long Island: the Birth of Brookhaven Lab (429th Brookhaven Lecture)

    International Nuclear Information System (INIS)

    Crease, Robert P.

    2007-01-01

    Robert P. Crease, historian for the U.S. Department of Energy's Brookhaven National Laboratory and Chair of the Philosophy Department at Stony Brook University, will give two talks on the Laboratory's history on October 31 and December 12. Crease's October 31 talk, titled 'How Big Science Came to Long Island: The Birth of Brookhaven Lab,' will cover the founding of the Laboratory soon after World War II as a peacetime facility to construct and maintain basic research facilities, such as nuclear reactors and particle accelerators, that were too large for single institutions to build and operate. He will discuss the key figures involved in starting the Laboratory, including Nobel laureates I.I. Rabi and Norman Ramsey, as well as Donald Dexter Van Slyke, one of the most renowned medical researchers in American history. Crease also will focus on the many problems that had to be overcome in creating the Laboratory and designing its first big machines, as well as the evolving relations of the Laboratory with the surrounding Long Island community and news media. Throughout his talk, Crease will tell fascinating stories about Brookhaven's scientists and their research.

  4. A neutronic feasibility study for LEU conversion of the Brookhaven Medical Research Reactor (BMRR).

    Energy Technology Data Exchange (ETDEWEB)

    Hanan, N. A.

    1998-01-14

    A neutronic feasibility study for converting the Brookhaven Medical Research Reactor from HEU to LEU fuel was performed at Argonne National Laboratory in cooperation with Brookhaven National Laboratory. Two possible LEU cores were identified that would provide nearly the same neutron flux and spectrum as the present HEU core at irradiation facilities that are used for Boron Neutron Capture Therapy and for animal research. One core has 17 and the other has 18 LEU MTR-type fuel assemblies with uranium densities of 2.5g U/cm{sup 3} or less in the fuel meat. This LEU fuel is fully-qualified for routine use. Thermal hydraulics and safety analyses need to be performed to complete the feasibility study.

  5. Brookhaven highlights

    International Nuclear Information System (INIS)

    Rowe, M.S.; Belford, M.; Cohen, A.; Greenberg, D.; Seubert, L.

    1993-01-01

    This report highlights the research activities of Brookhaven National Laboratory during the period dating from October 1, 1992 through September 30, 1993. There are contributions to the report from different programs and departments within the laboratory. These include technology transfer, RHIC, Alternating Gradient Synchrotron, physics, biology, national synchrotron light source, applied science, medical science, advanced technology, chemistry, reactor physics, safety and environmental protection, instrumentation, and computing and communications

  6. 75 FR 55631 - U. S. Rail Corporation-Construction and Operation Exemption-Brookhaven Rail Terminal

    Science.gov (United States)

    2010-09-13

    ... the proposed construction is to enable U. S. Rail to serve the BRT as a common carrier and to deliver... DEPARTMENT OF TRANSPORTATION Surface Transportation Board [Docket No. FD 35141] U. S. Rail Corporation--Construction and Operation Exemption-- Brookhaven Rail Terminal AGENCY: Surface Transportation...

  7. Clinical trials of boron neutron capture therapy [in humans] [at Beth Israel Deaconess Medical Center][at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Wallace, Christine

    2001-01-01

    Assessment of research records of Boron Neutron Capture Therapy was conducted at Brookhaven National Laboratory and Beth Israel Deaconess Medical Center using the Code of Federal Regulations, FDA Regulations and Good Clinical Practice Guidelines. Clinical data were collected FR-om subjects' research charts, and differences in conduct of studies at both centers were examined. Records maintained at Brookhaven National Laboratory were not in compliance with regulatory standards. Beth Israel's records followed federal regulations. Deficiencies discovered at both sites are discussed in the reports

  8. Brookhaven highlights

    International Nuclear Information System (INIS)

    Rowe, M.S.; Cohen, A.; Greenberg, D.; Seubert, L.

    1992-01-01

    This publication provides a broad overview of the research programs and efforts being conducted, built, designed, and planned at Brookhaven National Laboratory. This work covers a broad range of scientific disciplines. Major facilities include the Alternating Gradient Synchrotron (AGS), with its newly completed booster, the National Synchrotron Light Source (NSLS), the High Flux Beam Reactor (HFBR), and the RHIC, which is under construction. Departments within the laboratory include the AGS department, accelerator development, physics, chemistry, biology, NSLS, medical, nuclear energy, and interdepartmental research efforts. Research ranges from the pure sciences, in nuclear physics and high energy physics as one example, to environmental work in applied science to study climatic effects, from efforts in biology which are a component of the human genome project to the study, production, and characterization of new materials. The paper provides an overview of the laboratory operations during 1992, including staffing, research, honors, funding, and general laboratory plans for the future

  9. Brookhaven highlights

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, M.S.; Cohen, A.; Greenberg, D.; Seubert, L. (eds.)

    1992-01-01

    This publication provides a broad overview of the research programs and efforts being conducted, built, designed, and planned at Brookhaven National Laboratory. This work covers a broad range of scientific disciplines. Major facilities include the Alternating Gradient Synchrotron (AGS), with its newly completed booster, the National Synchrotron Light Source (NSLS), the High Flux Beam Reactor (HFBR), and the RHIC, which is under construction. Departments within the laboratory include the AGS department, accelerator development, physics, chemistry, biology, NSLS, medical, nuclear energy, and interdepartmental research efforts. Research ranges from the pure sciences, in nuclear physics and high energy physics as one example, to environmental work in applied science to study climatic effects, from efforts in biology which are a component of the human genome project to the study, production, and characterization of new materials. The paper provides an overview of the laboratory operations during 1992, including staffing, research, honors, funding, and general laboratory plans for the future.

  10. Interactive radiopharmaceutical facility between Yale Medical Center and Brookhaven National Laboratory. Progress report, October 1976-June 1979

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalk, A.

    1979-01-01

    DOE Contract No. EY-76-S-02-4078 was started in October 1976 to set up an investigative radiochemical facility at the Yale Medical Center which would bridge the gap between current investigation with radionuclides at the Yale School of Medicine and the facilities in the Chemistry Department at the Brookhaven National Laboratory. To facilitate these goals, Dr. Mathew L. Thakur was recruited who joined the Yale University faculty in March of 1977. This report briefly summarizes our research accomplishments through the end of June 1979. These can be broadly classified into three categories: (1) research using indium-111 labelled cellular blood components; (2) development of new radiopharmaceuticals; and (3) interaction with Dr. Alfred Wolf and colleagues in the Chemistry Department of Brookhaven National Laboratory.

  11. Interactive radiopharmaceutical facility between Yale Medical Center and Brookhaven National Laboratory. Progress report, October 1976-June 1979

    International Nuclear Information System (INIS)

    Gottschalk, A.

    1979-01-01

    DOE Contract No. EY-76-S-02-4078 was started in October 1976 to set up an investigative radiochemical facility at the Yale Medical Center which would bridge the gap between current investigation with radionuclides at the Yale School of Medicine and the facilities in the Chemistry Department at the Brookhaven National Laboratory. To facilitate these goals, Dr. Mathew L. Thakur was recruited who joined the Yale University faculty in March of 1977. This report briefly summarizes our research accomplishments through the end of June 1979. These can be broadly classified into three categories: (1) research using indium-111 labelled cellular blood components; (2) development of new radiopharmaceuticals; and (3) interaction with Dr. Alfred Wolf and colleagues in the Chemistry Department of Brookhaven National Laboratory

  12. MEQALAC development at Brookhaven

    International Nuclear Information System (INIS)

    Gammel, G.; Brodowski, J.; Keane, J.; Maschke, A.; Meier, E.; Mobley, R.; Sanders, R.

    1981-01-01

    A novel method of transporting and accelerating high brightness ion beams, called MEQALAC, has been developed at Brookhaven. The concept and its motivation will be described first, with reference to other sources for detail, and then the performance of two operating MEQALAC's will be presented

  13. Brookhaven highlights for fiscal year 1991, October 1, 1990--September 30, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, M.S.; Cohen, A.; Greenberg, D.; Seubert, L.; Kuper, J.B.H.

    1991-01-01

    This report highlights Brookhaven National Laboratory's activities for fiscal year 1991. Topics from the four research divisions: Computing and Communications, Instrumentation, Reactors, and Safety and Environmental Protection are presented. The research programs at Brookhaven are diverse, as is reflected by the nine different scientific departments: Accelerator Development, Alternating Gradient Synchrotron, Applied Science, Biology, Chemistry, Medical, National Synchrotron Light Source, Nuclear Energy, and Physics. Administrative and managerial information about Brookhaven are also disclosed. (GHH)

  14. Brookhaven highlights for fiscal year 1991, October 1, 1990--September 30, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, M.S.; Cohen, A.; Greenberg, D.; Seubert, L.; Kuper, J.B.H.

    1991-12-31

    This report highlights Brookhaven National Laboratory`s activities for fiscal year 1991. Topics from the four research divisions: Computing and Communications, Instrumentation, Reactors, and Safety and Environmental Protection are presented. The research programs at Brookhaven are diverse, as is reflected by the nine different scientific departments: Accelerator Development, Alternating Gradient Synchrotron, Applied Science, Biology, Chemistry, Medical, National Synchrotron Light Source, Nuclear Energy, and Physics. Administrative and managerial information about Brookhaven are also disclosed. (GHH)

  15. Brookhaven highlights for fiscal year 1991, October 1, 1990--September 30, 1991

    International Nuclear Information System (INIS)

    Rowe, M.S.; Cohen, A.; Greenberg, D.; Seubert, L.; Kuper, J.B.H.

    1991-01-01

    This report highlights Brookhaven National Laboratory's activities for fiscal year 1991. Topics from the four research divisions: Computing and Communications, Instrumentation, Reactors, and Safety and Environmental Protection are presented. The research programs at Brookhaven are diverse, as is reflected by the nine different scientific departments: Accelerator Development, Alternating Gradient Synchrotron, Applied Science, Biology, Chemistry, Medical, National Synchrotron Light Source, Nuclear Energy, and Physics. Administrative and managerial information about Brookhaven are also disclosed

  16. Brookhaven National Laboratory site environmental report for calendar year 1994

    International Nuclear Information System (INIS)

    Naidu, J.R.; Royce, B.A.

    1995-05-01

    This report documents the results of the Environmental Monitoring Program at Brookhaven National Laboratory and presents summary information about environmental compliance for 1994. To evaluate the effect of Brookhaven National Laboratory's operations on the local environment, measurements of direct radiation, and a variety of radionuclides and chemical compounds in ambient air, soil, sewage effluent, surface water, groundwater, fauna and vegetation were made at the Brookhaven National Laboratory site and at sites adjacent to the Laboratory

  17. Brookhaven National Laboratory

    Science.gov (United States)

    ... For Vendors Departments Public Events Newsroom Technology Licensing Stakeholder Relations Students & Educators Sustainability Privacy and security notice Brookhaven Science Associates Brookhaven Science Associates manages ...

  18. Brookhaven National Laboratory site environmental report for calendar year 1994

    Energy Technology Data Exchange (ETDEWEB)

    Naidu, J.R.; Royce, B.A. [eds.

    1995-05-01

    This report documents the results of the Environmental Monitoring Program at Brookhaven National Laboratory and presents summary information about environmental compliance for 1994. To evaluate the effect of Brookhaven National Laboratory`s operations on the local environment, measurements of direct radiation, and a variety of radionuclides and chemical compounds in ambient air, soil, sewage effluent, surface water, groundwater, fauna and vegetation were made at the Brookhaven National Laboratory site and at sites adjacent to the Laboratory.

  19. BROOKHAVEN: Booster commissioned

    Energy Technology Data Exchange (ETDEWEB)

    Bleser, Ed

    1992-03-15

    The construction and first commissioning phase of the Booster synchrotron to inject into Brookhaven's veteran Alternating Gradient Synchrotron (AGS) were completed last year. Scheduled to come into operation this year, the new Booster will extend the research capabilities AGS, and with its ability to accelerate partially stripped heavy ions will play an essential role in the chain of accelerators serving the Relativistic Heavy Ion Collider (RHIC)

  20. Brookhaven fastbus/unibus interface

    International Nuclear Information System (INIS)

    Benenson, G.; Bauernfeind, J.; Larsen, R.C.

    1983-01-01

    A typical high energy physics experiment requires both a high speed data acquisition and processing system, for data collection and reduction; and a general purpose computer to handle further reduction, bookkeeping and mass storage. Broad differences in architecture, format or technology, will often exist between these two systems, and interface design can become a formidable task. The PDP-11 series minicomputer is widely used in physics research, and the Brookhaven FASTBUS is the only standard high speed data acquisition system which is fully implemented in a current high energy physics experiment. This paper will describe the design and operation of an interface between these two systems. The major issues are elucidated by a preliminary discussion on the basic principles of Bus Systems, and their application to Brookhaven FASTBUS and UNIBUS

  1. Barrier Cavities in the Brookhaven AGS

    International Nuclear Information System (INIS)

    Blaskiewicz, M.; Brennan, J. M.; Roser, T.; Smith, K.; Spitz, R.; Zaltsman, A.; Fujieda, M.; Iwashita, Y.; Noda, A.; Yoshii, M.; Mori, Y.; Ohmori, C.; Sato, Y.

    1999-01-01

    In collaboration with KEK two barrier cavities, each generating 40 kV per turn have been installed in the Brookhaven AGS. Machine studies are described and their implications for high intensity operations are discussed

  2. Brookhaven National Laboratory site environmental report for calendar year 1996

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, G.L.; Paquette, D.E.; Naidu, J.R.; Lee, R.J.; Briggs, S.L.K.

    1998-01-01

    This report documents the results of the Environmental Monitoring Program at Brookhaven National Laboratory and summarizes information about environmental compliance for 1996. To evaluate the effect of Brookhaven National Laboratory`s operations on the local environment, measurements of direct radiation, and of a variety of radionuclides and chemical compounds in the ambient air, soil, sewage effluent, surface water, groundwater, fauna, and vegetation were made at the Brookhaven National Laboratory site and at adjacent sites. The report also evaluates the Laboratory`s compliance with all applicable guides, standards, and limits for radiological and non-radiological emissions and effluents to the environment.

  3. Department of Energy’s ARM Climate Research Facility External Data Center Operations Plan Located At Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Cialella, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gregory, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Lazar, K. [Brookhaven National Lab. (BNL), Upton, NY (United States); Liang, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ma, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tilp, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wagener, R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-01

    The External Data Center (XDC) Operations Plan describes the activities performed to manage the XDC, located at Brookhaven National Laboratory (BNL), for the Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility. It includes all ARM infrastructure activities performed by the Data Management and Software Engineering Group (DMSE) at BNL. This plan establishes a baseline of expectation within the ARM Operations Management for the group managing the XDC.

  4. BROOKHAVEN

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Neutrino physics has been an integral part of the Brookhaven research programme for much of the Laboratory's 46-year history. Milestones have been the determination of the helicity of neutrinos (1958), the establishment of the existence of two kinds of neutrinos (1962) for which Leon Lederman, Mel Schwartz and Jack Steinberger were awarded the 1988 Nobel Physics Prize, the discovery of charmed baryons in the 7' Bubble Chamber in 1975, and the ongoing measurements by Ray Davis and collaborators of solar neutrinos, first reported in 1968. There have also been significant contributions to the understanding of neutral currents in exclusive hadron and electron channels. In addition some of the earliest, and to date best, accelerator limits on electron muon neutrino oscillations are from Brookhaven experiments. The Laboratory is also the 'B' in the IMB underground experiment, built to search for proton decay and which caught neutrinos from the SN 1987a supernova. At present Brookhaven is heavily involved in the Gallex project in the Gran Sasso and recently a new collaboration has received scientific approval for a long baseline experiment to search for muon neutrino oscillations via muon neutrino disappearance

  5. Brookhaven FASTBUS ADC's

    International Nuclear Information System (INIS)

    Schmidt, M.P.; Black, J.K.; Blatt, S.R.

    1983-01-01

    A high energy physics experiment has been performed at Brookhaven National Laboratory on k/sub L/ 0 → 2π 0 decays employing a large (> 200 element) lead glass array as an electromagnetic calorimeter. To acquire pulse height information from the detector we have constructed ADC modules in the context of the Brookhaven Fastbus data acquisition system. Digitization (8 bits) and encoding, including pedestal subtraction and data sparsing, is achieved for each 16 channel module in 6 μsec

  6. BROOKHAVEN: Getting a boost

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Some recent scenarios for the future of US high energy physics have glossed over the ongoing high energy physics role of Brookhaven's Alternating Gradient Synchrotron (AGS), seeing it being relegated essentially to a service function as the injector for the RHIC heavy ion collider. However this view is not shared by Brookhaven, now enjoying the benefits of a Booster to inject into the AGS

  7. Landmarks in particle physics at Brookhaven National Laboratory: Brookhaven Lecture Series, Number 238

    International Nuclear Information System (INIS)

    Adair, R.K.

    1987-01-01

    Robert Adair's lecture on Landmarks in Particle Physics at Brookhaven National Laboratory (BNL) is a commemoration of the 40th Anniversary of Brookhaven National Laboratory. Adair describes ten researches in elementary particle physics at Brookhaven that had a revolutionary impact on the understanding of elementary particles. Two of the discoveries were made in 1952 and 1956 at the Cosmotron, BNL's first proton accelerator. Four were made in 1962 and 1964 at the Alternating Gradient Synchrotron, the Cosmotron's replacement. Two other discoveries in 1954 and 1956 were theoretical, and strong focusing (1952) is the only technical discovery. One discovery (1958) happened in an old barrack. Four of the discoveries were awarded the Nobel prize in Physics. Adair believes that all of the discoveries are worthy of the Nobel prize. 14 figs

  8. BROOKHAVEN: RHIC installation

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    This summer, the first superconducting magnet was installed in 3.8 kilometre tunnel for Brookhaven's RHIC heavy ion collider (October, page 31). Manufactured by Northrop Grumman's Electronics and System Integration Division, the magnet is the first of RHIC's 373 dipoles. In addition to the dipoles, Northrop Grumman will also provide 432 RHIC quadrupoles. The first quadrupole was delivered on 8 April, a month before the first dipole arrived for onsite testing prior to installation. RHIC will need 1,700 superconducting magnets - dipoles, quadrupoles, sextupoles and correcting magnets, 1,200 of which will be built by industry and the rest built at Brookhaven. The 300 sextupoles are being supplied by Everson Electric

  9. BROOKHAVEN NATIONAL LABORATORY INSTITUTIONAL PLAN FY2003-2007.

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-06-10

    This document presents the vision for Brookhaven National Laboratory (BNL) for the next five years, and a roadmap for implementing that vision. Brookhaven is a multidisciplinary science-based laboratory operated for the U.S. Department of Energy (DOE), supported primarily by programs sponsored by the DOE's Office of Science. As the third-largest funding agency for science in the U.S., one of the DOE's goals is ''to advance basic research and the instruments of science that are the foundations for DOE's applied missions, a base for U.S. technology innovation, and a source of remarkable insights into our physical and biological world, and the nature of matter and energy'' (DOE Office of Science Strategic Plan, 2000 http://www.osti.gov/portfolio/science.htm). BNL shapes its vision according to this plan.

  10. Brookhaven National Laboratory site environmental report for calendar year 1995

    Energy Technology Data Exchange (ETDEWEB)

    Naidu, J.R.; Paquette, D.E.; Schroeder, G.L. [eds.] [and others

    1996-12-01

    This report documents the results of the Environmental Monitoring Program at Brookhaven National Laboratory and summarizes information about environmental compliance for 1995. To evaluate the effect of Brookhaven National Laboratory`s operations on the local environment, measurements of direct radiation, and of a variety of radionuclides and chemical compounds in the ambient air, soil, sewage effluent, surface water, groundwater, fauna, and vegetation were made at the Brookhaven National Laboratory site and at adjacent sites. The report also evaluates the Laboratory`s compliance with all applicable guides, standards, and limits for radiological and nonradiological emissions and effluents to the environment. Areas of known contamination are subject to Remedial Investigation/Feasibility Studies under the Inter Agency Agreement established by the Department of Energy, Environmental Protection Agency and the New York Department of Environmental Conservation. Except for identified areas of soil and groundwater contamination, the environmental monitoring data has continued to demonstrate that compliance was achieved with the applicable environmental laws and regulations governing emission and discharge of materials to the environment. Also, the data show that the environmental impacts at Brookhaven National Laboratory are minimal and pose no threat to the public nor to the environment. This report meets the requirements of Department of Energy Orders 5484.1, Environmental Protection, Safety, and Health Protection Information reporting requirements and 5400.1, General Environmental Protection Programs.

  11. The Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.

    1992-01-01

    The Brookhaven National Laboratory Accelerator Test Facility comprises a 50 MeV traveling wave electron linear accelerator utilizing a high gradient, photo-excited, raidofrequency electron gun as an injector and an experimental area for study of new acceleration methods or advanced radiation sources using free electron lasers. Early operation of the linear accelerator system including calculated and measured beam parameters are presented together with the experimental program for accelerator physics and free electron laser studies

  12. BROOKHAVEN: Looking towards heavy ion physics

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    July 11-22 were busy days at Brookhaven with a two-week Summer Institute on Relativistic Heavy Ion Physics. After an intensive first week designed to introduce young physicists to high energy heavy ion research, the second week was a workshop on detector technology for Brookhaven's proposed Relativistic Heavy Ion Collider (RHIC), attended by some 150 physicists

  13. Dr. Praveen Chaudhari named director of Brookhaven National Laboratory

    CERN Multimedia

    2003-01-01

    "Brookhaven Science Associates announced today the selection of Dr. Praveen Chaudhari as Director of the U.S. Department of Energy's Brookhaven National Laboratory. Dr. Chaudhari, who will begin his new duties on April 1, joins Brookhaven Lab after 36 years of distinguished service at IBM as a scientist and senior manager of research" (1 page).

  14. Construction and operation of a 10 MeV electron accelerator and associated experimental facilities at Brookhaven National Laboratory, Upton, New York. Environmental assessment

    International Nuclear Information System (INIS)

    1994-02-01

    The purpose of this environmental impact statement is to determine whether there would be significant environmental impacts associated with the construction of an experimental facility at Brookhaven National Laboratory for radiation chemistry research and operation of the 10-MeV electron accelerator proposed for it. The document describes the need for action, alternative actions, the affected environment, and potential environmental impacts

  15. OPTIMIZATION OF THE EPITHERMAL NEUTRON BEAM FOR BORON NEUTRON CAPTURE THERAPY AT THE BROOKHAVEN MEDICAL RESEARCH REACTOR.

    Energy Technology Data Exchange (ETDEWEB)

    HU,J.P.; RORER,D.C.; RECINIELLO,R.N.; HOLDEN,N.E.

    2002-08-18

    Clinical trials of Boron Neutron Capture Therapy for patients with malignant brain tumor had been carried out for half a decade, using an epithermal neutron beam at the Brookhaven's Medical Reactor. The decision to permanently close this reactor in 2000 cut short the efforts to implement a new conceptual design to optimize this beam in preparation for use with possible new protocols. Details of the conceptual design to produce a higher intensity, more forward-directed neutron beam with less contamination from gamma rays, fast and thermal neutrons are presented here for their potential applicability to other reactor facilities. Monte Carlo calculations were used to predict the flux and absorbed dose produced by the proposed design. The results were benchmarked by the dose rate and flux measurements taken at the facility then in use.

  16. Brookhaven segment interconnect

    International Nuclear Information System (INIS)

    Morse, W.M.; Benenson, G.; Leipuner, L.B.

    1983-01-01

    We have performed a high energy physics experiment using a multisegment Brookhaven FASTBUS system. The system was composed of three crate segments and two cable segments. We discuss the segment interconnect module which permits communication between the various segments

  17. Brookhaven Linac Isotope Producer

    Data.gov (United States)

    Federal Laboratory Consortium — The Brookhaven Linac Isoptope Producer (BLIP)—positioned at the forefront of research into radioisotopes used in cancer treatment and diagnosis—produces commercially...

  18. Upgrades of the epithermal neutron beam at the Brookhaven Medical Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hungyuan B.; Brugger, R.M.; Rorer, D.C.

    1994-12-31

    The first epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR) was installed in 1988 and produced a neutron beam that was satisfactory for the development of NCT with epithermal neutrons. This beam was used routinely until 1992 when the beam was upgraded by rearranging fuel elements in the reactor core to achieve a 50% increase in usable flux. Next, after computer modeling studies, it was proposed that the Al and Al{sub 2}O{sub 3} moderator material in the shutter that produced the epithermal neutrons could be rearranged to enhance the beam further. However, this modification was not started because a better option appeared, namely to use fission plates to move the source of fission neutrons closer to the moderator and the patient irradiation position to achieve more efficient moderation and production of epithermal neutrons. A fission plate converter (FPC) source has been designed recently and, to test the concept, implementation of this upgrade has started. The predicted beam parameters will be 12 x 10{sup 9} n{sub epi}/cm{sup 2}sec accompanying with doses from fast neutrons and gamma rays per epithermal neutron of 2.8 x 10{sup -11} and < 1 x 10{sup -11} cGycm{sup 2}/n, respectively, and a current-to-flux ratio of epithermal neutrons of 0.78. This conversion could be completed by late 1996.

  19. Installation and testing of an optimized epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR)

    Energy Technology Data Exchange (ETDEWEB)

    Fairchild, R.G.; Kalef-Ezra, J.; Saraf, S.K.; Fiarman, S.; Ramsey, E.; Wielopolski, L.; Laster, B.; Wheeler, F. (Brookhaven National Lab., Upton, NY (USA); Ioannina Univ. (Greece); Brookhaven National Lab., Upton, NY (USA); State Univ. of New York, Stony Brook, NY (USA). Health Science Center; Brookhaven National Lab., Upton, NY (USA); EG and G Idaho, Inc., Idaho Falls, ID (USA))

    1989-01-01

    Various calculations indicate that an optimized epithermal neutron beam can be produced by moderating fission neutrons either with a combination of Al and D{sub 2}O, or with Al{sub 2}O{sub 3}. We have designed, installed and tested an Al{sub 2}O{sub 3} moderated epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR). The epithermal neutron fluence rate of 1.8 {times} 10{sup 9} n/cm{sup 2}-sec produces a peak thermal neutron fluence rate of 1.9 to 2.8 {times} 10{sup 9} n/cm{sup 2}-sec in a tissue equivalent (TE) phantom head, depending on the configuration. Thus a single therapy treatment of 5 {times} 10{sup 12} n/cm{sup 2} can be delivered in 30--45 minutes. All irradiation times are given for a BMRR power of 3 MW, which is the highest power which can be delivered continuously. 18 refs., 8 figs., 4 tabs.

  20. Brookhaven highlights. Report on research, October 1, 1992--September 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, M.S.; Belford, M.; Cohen, A.; Greenberg, D.; Seubert, L. [eds.

    1993-12-31

    This report highlights the research activities of Brookhaven National Laboratory during the period dating from October 1, 1992 through September 30, 1993. There are contributions to the report from different programs and departments within the laboratory. These include technology transfer, RHIC, Alternating Gradient Synchrotron, physics, biology, national synchrotron light source, applied science, medical science, advanced technology, chemistry, reactor physics, safety and environmental protection, instrumentation, and computing and communications.

  1. The Brookhaven Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Chou, T.S.; Fernow, R.C.

    1988-01-01

    The Brookhaven Accelerator Test Facility (ATF) will consist of a 50--100 MeV/c electron linac and a 100 GW CO 2 laser system. A high brightness RF-gun operating at 2856 MHz is to be used as the injector into the linac. The RF-gun contains a Nd:Yag-laser-driven photocathode capable of producing a stream of six ps electron pulses separated by 12.5 ns. The maximum charge in a micropulse will be one nano-Coulomb. The CO 2 laser pulse length will be a few picoseconds and will be synchronized with the electron pulse. The first experimental beam is expected in Fall 89. The design electron beam parameters are given and possible initial experiments are discussed. 9 refs., 1 fig., 3 tabs

  2. The superconducting x-ray lithography source program at Brookhaven

    Energy Technology Data Exchange (ETDEWEB)

    Williams, G. P.; Heese, R. N.; Vignola, G.; Murphy, J. B.; Godel, J. B.; Hsieh, H.; Galayda, J.; Seifert, A.; Knotek, M. L.

    1989-07-01

    A compact electron storage ring with superconducting dipole magnets, is being developed at the National Synchrotron Light Source at Brookhaven. The parameters of the source have been optimized for its future use as an x-ray source for lithography. This first ring is a prototype which will be used to study the operating characteristics of machines of this type with particular attention being paid to low-energy injection and long beam lifetime.

  3. Brookhaven highlights. [Fiscal year 1992, October 1, 1991--September 30, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, M.S.; Cohen, A.; Greenberg, D.; Seubert, L. [eds.

    1992-12-31

    This publication provides a broad overview of the research programs and efforts being conducted, built, designed, and planned at Brookhaven National Laboratory. This work covers a broad range of scientific disciplines. Major facilities include the Alternating Gradient Synchrotron (AGS), with its newly completed booster, the National Synchrotron Light Source (NSLS), the High Flux Beam Reactor (HFBR), and the RHIC, which is under construction. Departments within the laboratory include the AGS department, accelerator development, physics, chemistry, biology, NSLS, medical, nuclear energy, and interdepartmental research efforts. Research ranges from the pure sciences, in nuclear physics and high energy physics as one example, to environmental work in applied science to study climatic effects, from efforts in biology which are a component of the human genome project to the study, production, and characterization of new materials. The paper provides an overview of the laboratory operations during 1992, including staffing, research, honors, funding, and general laboratory plans for the future.

  4. BROOKHAVEN NATIONAL LABORATORY SITE ENVIRONMENTAL REPORT FOR CALENDAR YEAR 1994.

    Energy Technology Data Exchange (ETDEWEB)

    NAIDU,J.R.; ROYCE,B.A.

    1995-05-01

    This report documents the results of the Environmental Monitoring Program at Brookhaven National Laboratory and presents summary information about environmental compliance for 1994. To evaluate the effect of Brookhaven National Laboratory's operations on the local environment, measurements of direct radiation, and a variety of radionuclides and chemical compounds in ambient air, soil, sewage effluent, surface water, groundwater, fauna and vegetation were made at the Brookhaven National Laboratory site and at sites adjacent to the Laboratory. Brookhaven National Laboratory's compliance with all applicable guides, standards, and limits for radiological and nonradiological emissions and effluents to the environment were evaluated. Among the permitted facilities, two instances of pH exceedances were observed at recharge basins, possibly related to rain-water run-off to these recharge basins. Also, the discharge from the Sewage Treatment Plant to the Peconic River exceeded. on ten occasions, one each for fecal coliform and 5-day Biochemical Oxygen Demand (avg.) and eight for ammonia nitrogen. The ammonia and Biochemical Oxygen Demand exceedances were attributed to the cold winter and the routine cultivation of the sand filter beds which resulted in the hydraulic overloading of the filter beds and the possible destruction of nitrifying bacteria. The on-set of warm weather and increased aeration of the filter beds via cultivation helped to alleviate this condition. The discharge of fecal coliform may also be linked to this occurrence, in that the increase in fecal coliform coincided with the increased cultivation of the sand filter beds. The environmental monitoring data has identified site-specific contamination of groundwater and soil. These areas are subject to Remedial Investigation/Feasibility Studies under the Inter Agency Agreement. Except for the above, the environmental monitoring data has continued to demonstrate that compliance was achieved with

  5. Small Modular Reactors (468th Brookhaven Lecture)

    International Nuclear Information System (INIS)

    Bari, Robert

    2011-01-01

    With good reason, much more media attention has focused on nuclear power plants than solar farms, wind farms, or hydroelectric plants during the past month and a half. But as nations around the world demand more energy to power everything from cell phone batteries to drinking water pumps to foundries, nuclear plants are the only non-greenhouse-gas producing option that can be built to operate almost anywhere, and can continue to generate power during droughts, after the sun sets, and when winds die down. To supply this demand for power, designers around the world are competing to develop more affordable nuclear reactors of the future: small modular reactors. Brookhaven Lab is working with DOE to ensure that these reactors are designed to be safe for workers, members of surrounding communities, and the environment and to ensure that the radioactive materials and technology will only be used for peaceful purposes, not weapons. In his talk, Bari will discuss the advantages and challenges of small modular reactors and what drives both international and domestic interest in them. He will also explain how Brookhaven Lab and DOE are working to address the challenges and provide a framework for small modular reactors to be commercialized.

  6. Brookhaven highlights, 1986-1987

    International Nuclear Information System (INIS)

    Rowe, M.S.

    1988-01-01

    The highlights of research conducted between October 1985 and September 1987 at Brookhaven National Laboratory are reviewed in this publication. Also covered are the administrative and financial status of the laboratory and a brief mention of meetings held and honors received. (FI)

  7. Design of small-animal thermal neutron irradiation facility at the Brookhaven Medical Research Reactor

    International Nuclear Information System (INIS)

    Liu, H.B.

    1996-01-01

    The broad beam facility (BBF) at the Brookhaven Medical Research Reactor (BMRR) can provide a thermal neutron beam with flux intensity and quality comparable to the beam currently used for research on neutron capture therapy using cell-culture and small-animal irradiations. Monte Carlo computations were made, first, to compare with the dosimetric measurements at the existing BBF and, second, to calculate the neutron and gamma fluxes and doses expected at the proposed BBF. Multiple cell cultures or small animals could be irradiated simultaneously at the so-modified BBF under conditions similar to or better than those individual animals irradiated at the existing thermal neutron irradiation Facility (TNIF) of the BMRR. The flux intensity of the collimated thermal neutron beam at the proposed BBF would be 1.7 x 10 10 n/cm 2 ·s at 3-MW reactor power, the same as at the TNIF. However, the proposed collimated beam would have much lower gamma (0.89 x 10 -11 cGy·cm 2 /n th ) and fast neutron (0.58 x 10 -11 cGy·cm 2 /n th ) contaminations, 64 and 19% of those at the TNIF, respectively. The feasibility of remodeling the facility is discussed

  8. First experiences with a fastbus system at Brookhaven

    International Nuclear Information System (INIS)

    Leipuner, L.B.; Larsen, R.C.; Makowiecki, D.S.

    1980-01-01

    A new concept in high energy data acquisition systems called Fastbus has been developed and implemented at Brookhaven. The system which is capable of sub-gigabit/sec speeds has been operating for some time now. A number of modules including an on-bus processor, a PDP11 interface, 32 channel coincidence latches, a 16 channel scaler, a 32 channel μ-clock device, a 60 nsec memory and a predetermined time module have been developed and built. Features of the system include extensive use of ECL logic and a water cooled crate with conduction heat transfer within a module. The system is used in an on-line experiment at the AGS. Operating experience will be discussed

  9. Digital transverse beam dampers from the Brookhaven AGS

    International Nuclear Information System (INIS)

    Smith, G.A.; Castillo, V.; Roser, T.; Van Asselt, W.; Witkover, R.; Wong, V.

    1995-01-01

    A wide band, digital damper system has been developed and is in use at the Brookhaven Alternating Gradient Synchrotron (AGS). The system consists of vertical and horizontal capacitive pickups, analog and digital processing electronics, four 500 Watt wide band power amplifiers, and two pairs of strip line beam kickers. The system is currently used to damp transverse coherent instabilities and injection errors, in both planes, for protons and all species of heavy ions. This paper discusses the system design and operation, particularly with regard to stabilization of the high intensity proton beam. The analog and digital signal processing techniques used to achieve optimum results are discussed. Operational data showing the effect of the damping are presented

  10. The Brookhaven Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Chou, T.S.; Fernow, R.C.; Fischer, J.; Gallardo, J.; Kirk, H.G.; Koul, R.; Palmer, R.B.; Pellegrini, C.; Sheehan, J.; Srinivasan-Rao, T.; Ulc, S.; Woodle, M.; Bigio, I.; Kurnit, N.; McDonald, K.T.

    1989-01-01

    The Brookhaven Accelerator Test Facility ATF will consist of a 50-100 MeV/c electron linac and a 100 GW CO 2 laser system. A high brightness RF-gun operating at 2,856 MHz is to be used as the injector into the linac. The RF-gun contains a Nd:Yag-laser-driven photocathode capable of producing a stream of six ps electron pulses separated by 12.5 ns. The maximum charge in a micropulse will be one nano-Coulomb. The CO 2 laser pulse length will be a few picoseconds and will be synchronized with the electron pulse. The first experimental beam is expected in Fall 89. The design electron beam parameters are given and possible initial experiments are discussed. 9 refs., 1 fig., 3 tabs

  11. Epithermal beam development at the BMRR [Brookhaven Medical Research Reactor]: Dosimetric evaluation

    International Nuclear Information System (INIS)

    Saraf, S.K.; Fairchild, R.G.; Kalef-Ezra, J.; Laster, B.H.; Fiarman, S.; Ramsey, E.; Ioannina Univ.; Brookhaven National Lab., Upton, NY; State Univ. of New York, Stony Brook, NY

    1989-01-01

    The utilization of an epithermal neutron beam for neutron capture therapy (NCT) is desirable because of the increased tissue penetration relative to a thermal neutron beam. Over the past few years, modifications have been and continue to be made at the Brookhaven Medical Research Reactor (BMRR) by changing its filter components to produce an optimal epithermal beam. An optimal epithermal beam should contain a low fast neutron contamination and no thermal neutrons in the incident beam. Recently a new moderator for the epithermal beam has been installed at the epithermal port of the BMRR and has accomplished this task. This new moderator is a combination of alumina (Al 2 O 3 ) bricks and aluminum (Al) plates. A 0.51 mm thick cadmium (Cd) sheet has reduced the thermal neutron intensity drastically. Furthermore, an 11.5 cm thick bismuth (Bi) plate installed at the port surface has reduced the gamma dose component to negligible levels. Foil activation techniques have been employed by using bare gold and cadmium-covered gold foil to determine thermal as well as epithermal neutron fluence. Fast neutron fluence has been determined by indium foil counting. Fast neutron and gamma dose in soft tissue, free in air, is being determined by the paired ionization chamber technique, using tissue equivalent (TE) and graphite chambers. Thermoluminescent dosimeters (TLD-700) have also been used to determine the gamma dose independently. This paper describes the methods involved in the measurements of the above mentioned parameters. Formulations have been developed and the various corrections involved have been detailed. 12 refs

  12. Brookhaven highlights, October 1978-September 1979

    International Nuclear Information System (INIS)

    1979-01-01

    These highlights present an overview of the major research and development achievements at Brookhaven National Laboratory from October 1978 to September 1979. Specific areas covered include: accelerator and high energy physics programs; high energy physics research; the AGS and improvements to the AGS; neutral beam development; heavy ion fusion; superconducting power cables; ISABELLE storage rings; the BNL Tandem accelerator; heavy ion experiments at the Tandem; the High Flux Beam Reactor; medium energy physics; nuclear theory; atomic and applied physics; solid state physics; neutron scattering studies; x-ray scattering studies; solid state theory; defects and disorder in solids; surface physics; the National Synchrotron Light Source ; Chemistry Department; Biology Department; Medical Department; energy sciences; environmental sciences; energy technology programs; National Center for Analysis of Energy Systems; advanced reactor systems; nuclear safety; National Nuclear Data Center; nuclear materials safeguards; Applied Mathematics Department; and support activities

  13. Performance of the Brookhaven photocathode rf gun

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Fernow, R.C.; Fischer, J.; Fisher, A.S.; Gallardo, J.; Ingold, G.; Kirk, H.G.; Leung, K.P.; Malone, R.; Pogorelsky, I.; Srinivasan-Rao, T.; Rogers, J.; Tsang, T.; Sheehan, J.; Ulc, S.; Woodle, M.; Xie, J.; Zhang, R.S.; Lin, L.Y.; McDonald, K.T.; Russell, D.P.; Hung, C.M.; Wang, X.J.

    1991-01-01

    The Brookhaven Accelerator Test Facility (ATF) uses a photocathode rf gun to provide a high-brightness electron beam intended for FEL and laser-acceleration experiments. The rf gun consists of 1 1/2 cells driven at 2856 MHz in π-mode with a maximum cathode field of 100 MV/m. To achieve long lifetimes, the photocathode development concentrates on robust metals such as copper, yttrium and samarium. We illuminate these cathodes with a 10-ps, frequency-quadrupled Nd:YAG laser. We describe the initial operation of the gun, including measurements of transverse and longitudinal emittance, quantum efficiencies, and peak current. The results are compared to models

  14. BROOKHAVEN: High energy gold

    International Nuclear Information System (INIS)

    Bleser, Ed

    1992-01-01

    On April 24, Brookhaven's Alternating Gradient Synchrotron (AGS) started to deliver gold ions at 11.4 GeV per nucleon (2,000 GeV per ion) to experimenters who were delighted not only to receive the world's highest energy gold beam but also to receive it on schedule

  15. BROOKHAVEN: Glueballs, hybrids and exotics

    Energy Technology Data Exchange (ETDEWEB)

    Chung, S. -U.

    1988-12-15

    A workshop at Brookhaven from August 29 to September 1 looked at the current status of hadron spectroscopy beyond the realm of states conventionally built up from quarks and discussed future experimental effort to explore such exotic states.

  16. Brookhaven Highlights, January 1982-March 1983

    Energy Technology Data Exchange (ETDEWEB)

    Kuper, J.B.H.; Rustad, M.C. (eds.)

    1983-01-01

    Research at Brookhaven National Laboratory is summarized. Major headings are high energy physics, physics and chemistry, life sciences, applied energy science, support activities and administration. (GHT)

  17. Brookhaven Reactor Experiment Control Facility, a distributed function computer network

    International Nuclear Information System (INIS)

    Dimmler, D.G.; Greenlaw, N.; Kelley, M.A.; Potter, D.W.; Rankowitz, S.; Stubblefield, F.W.

    1975-11-01

    A computer network for real-time data acquisition, monitoring and control of a series of experiments at the Brookhaven High Flux Beam Reactor has been developed and has been set into routine operation. This reactor experiment control facility presently services nine neutron spectrometers and one x-ray diffractometer. Several additional experiment connections are in progress. The architecture of the facility is based on a distributed function network concept. A statement of implementation and results is presented

  18. Effective mass trigger at the Brookhaven Multi-Particle Spectrometer (MPS)

    International Nuclear Information System (INIS)

    Willen, E.H.

    1980-01-01

    An effective mass trigger for use at the Brookhaven Multiparticle Spectrometer (MPS) is described. It is a microprocessor based device using extensive fast memory attached to proportional wire chambers in the MPS magnetic field. It will select kinematic quantities unique to the reaction being studied, thereby permitting higher sensitivities and a reduction in data-processing cost for MPS experiments. The principles of operation for this trigger, and the results of simulations to assess its performance, are presented

  19. Brookhaven National Laboratory Institutional Plan FY2001--FY2005

    Energy Technology Data Exchange (ETDEWEB)

    Davis, S.

    2000-10-01

    Brookhaven National Laboratory is a multidisciplinary laboratory in the Department of Energy National Laboratory system and plays a lead role in the DOE Science and Technology mission. The Laboratory also contributes to the DOE missions in Energy Resources, Environmental Quality, and National Security. Brookhaven strives for excellence in its science research and in facility operations and manages its activities with particular sensitivity to environmental and community issues. The Laboratory's programs are aligned continuously with the goals and objectives of the DOE through an Integrated Planning Process. This Institutional Plan summarizes the portfolio of research and capabilities that will assure success in the Laboratory's mission in the future. It also sets forth BNL strategies for our programs and for management of the Laboratory. The Department of Energy national laboratory system provides extensive capabilities in both world class research expertise and unique facilities that cannot exist without federal support. Through these national resources, which are available to researchers from industry, universities, other government agencies and other nations, the Department advances the energy, environmental, economic and national security well being of the US, provides for the international advancement of science, and educates future scientists and engineers.

  20. Construction and operation of an improved radiation calibration facility at Brookhaven National Laboratory. Environmental assessment

    International Nuclear Information System (INIS)

    1994-10-01

    Calibration of instruments used to detect and measure ionizing radiation has been conducted over the last 20 years at Brookhaven National Laboratory's (BNL) Radiation Calibration Facility, Building 348. Growth of research facilities, projects in progress, and more stringent Department of Energy (DOE) orders which involve exposure to nuclear radiation have placed substantial burdens on the existing radiation calibration facility. The facility currently does not meet the requirements of DOE Order 5480.4 or American National Standards Institute (ANSI) N323-1978, which establish calibration methods for portable radiation protection instruments used in the detection and measurement of levels of ionizing radiation fields or levels of radioactive surface contaminations. Failure to comply with this standard could mean instrumentation is not being calibrated to necessary levels of sensitivity. The Laboratory has also recently obtained a new neutron source and gamma beam irradiator which can not be made operational at existing facilities because of geometry and shielding inadequacies. These sources are needed to perform routine periodic calibrations of radiation detecting instruments used by scientific and technical personnel and to meet BNL's substantial increase in demand for radiation monitoring capabilities. To place these new sources into operation, it is proposed to construct an addition to the existing radiation calibration facility that would house all calibration sources and bring BNL calibration activities into compliance with DOE and ANSI standards. The purpose of this assessment is to identify potential significant environmental impacts associated with the construction and operation of an improved radiation calibration facility at BNL

  1. Brookhaven: RHIC magnets

    International Nuclear Information System (INIS)

    Heppelman, Steve

    1990-01-01

    Last year, Brookhaven's proposal for a Relativistic Heavy Ion Collider - RHIC - was scrutinized by the US Department of Energy and deemed to be ready for construction funding. The hope is that the money will be voted soon so that construction can get underway at the start of the new US financial year in October. The 3.8 kilometre RHIC tunnel was completed ten years ago for the doomed Isabelle/CBA proton collider project

  2. The Royal Naval Medical Services: delivering medical operational capability. the 'black art' of Medical Operational Planning.

    Science.gov (United States)

    Faye, M

    2013-01-01

    This article looks to dispel the mysteries of the 'black art' of Medical Operational Planning whilst giving an overview of activity within the Medical Operational Capability area of Medical Division (Med Div) within Navy Command Headquarters (NCHQ) during a period when the Royal Naval Medical Services (RNMS) have been preparing and reconfiguring medical capability for the future contingent battle spaces. The rolling exercise program has been used to illustrate the ongoing preparations taken by the Medical Operational Capability (Med Op Cap) and the Medical Force Elements to deliver medical capability in the littoral and maritime environments.

  3. Short-lived radionuclide production capability at the Brookhaven Linac Isotope Producer

    International Nuclear Information System (INIS)

    Mausner, L.F.; Richards, P.

    1985-01-01

    The Brookhaven National Linac Isotope Producer is the first facility to demonstrate the capability of a large linear accelerator for efficient and economical production of difficult-to-make, medically useful radionuclides. The linac provides a beam of 200-MeV protons at an integrated beam current of up to 60 μA. The 200-MeV proton energy is very suitable for isotope production because the spallation process can create radionuclides unavailable at lower energy accelerators or reactors. Several medically important short-lived radionuclides are presently being prepared for on-site and off-site collaborative research programs. These are iodine-123, iron-52, manganese-52m, ruthenium-97, and the rubidium-81-krypton-81m system. The production parameters for these are summarized

  4. Brookhaven at 40 - looking forward as well as back

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    In 1947, the famous Camp Upton Army Base on New York's Long Island switched to a new career as Brookhaven National Laboratory. The reputation the Laboratory has established as a world-class research centre and its continued attraction for scientists looking for exciting possibilities were highlighted on 9-11 September at a symposium and celebration marking forty years of Brookhaven and its parent organization, AUI (Associated Universities Inc)

  5. Brookhaven leak reactor to close

    CERN Multimedia

    MacIlwain, C

    1999-01-01

    The DOE has announced that the High Flux Beam Reactor at Brookhaven is to close for good. Though the news was not unexpected researchers were angry the decision had been taken before the review to assess the impact of reopening the reactor had been concluded (1 page).

  6. MWPC data acquisition in the Brookhaven FASTBUS

    International Nuclear Information System (INIS)

    Black, J.K.; Blatt, S.R.; Campbell, M.C.

    1983-01-01

    For Brookhaven AGS Experiment No. 749, a data acquisition system to accommodate 12, 256 wire multiwire proportional chambers (MWPCs) has been built in the context of the Brookhaven FASTBUS. Information about wires hit or continuous clusters of wires hit is encoded as the centroids of the clusters and number of wires in those clusters. The encoded information is stored in a stack memory in a FASTBUS module where it can be accessed by a FASTBUS Master. Encoding time is less than 4 microseconds. Also, information (in the form of front panel outputs) as to the nature of the data is available in less than 200 nanoseconds

  7. The first picosecond terawatt CO2 laser at the Brookhaven Accelerator Test Facility

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.; Ben-Zvi, I.; Babzien, M.

    1998-02-01

    The first terawatt picosecond CO 2 laser will be brought to operation at the Brookhaven Accelerator Test Facility in 1998. System consists of a single-mode TEA oscillator, picosecond semiconductor optical switch, multi-atmosphere. The authors report on design, simulation, and performance tests of the 10 atm final amplifier that allows for direct multi-joule energy extraction in a picosecond laser pulse

  8. Upgrade of the controls for the Brookhaven linac

    International Nuclear Information System (INIS)

    Buxton, W.E.

    1995-01-01

    The control of the magnets, rf system, and other components at the Brookhaven Linac uses a system that was developed at Brookhaven in the late 1960's. This system will be retired in the summer of 1995. The Linac controls are being upgraded using modem VME-based hardware compatible with RHIC generation controls, and an existing serial field bus. The timing for the Linac will also be upgraded and will use components developed for RHIC. The controls in general, the timing for the Linac, and the modules developed will be described

  9. TRISTAN-II at Brookhaven

    International Nuclear Information System (INIS)

    Chrien, R.E.; Stelts, M.L.; Manzella, V.; Gill, R.; Wohn, F.; Hill, J.C.

    1979-01-01

    The mass separator TRISTAN has been moved to Brookhaven HFBR. A flux of up to 10 11 neutrons/cm 2 /sec will be available on target, and improvements in the ion source and beam optics have been made. A computer system with a CAMAC interface allows data collection from eight independent sources, while a PDP-11/34 computer is available for extensive off-line analysis

  10. MACHINE PROTECTION SYSTEM FOR CONCURRENT OPERATION OF RHIC AND BLIP

    International Nuclear Information System (INIS)

    WILINSKI, M.; BELLAVIA, S.; GLENN, J.W.; MAUSNER, L.F.; UNGER, K.L.

    2005-01-01

    The Brookhaven 200MeV linac is a multipurpose machine used to inject low intensity polarized protons for RHIC (Relativistic Heavy Ion Collider), as well as to inject high intensity protons to BLIP (Brookhaven Linac Isotope Producer), a medical isotope production facility. If high intensity protons were injected to RHIC by mistake, administrative radiation limits could be exceeded or sensitive electronics could be damaged. In the past, the changeover from polarized proton to high intensity proton operation has been a lengthy process, thereby never allowing the two programs to run simultaneously. To remedy this situation and allow concurrent operation of RHIC and BLIP, an active interlock system has been designed to monitor current levels in the AGS using two current transformers with fail safe circuitry and associated electronics to inhibit beam to RHIC if high intensity currents are detected

  11. Tiger Team assessment of the Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    This report documents the results of the Department of Energy's (DOE's) Tiger Team Assessment conducted at Brookhaven National Laboratory (BNL) in Upton, New York, between March 26 and April 27, 1990. The BNL is a multiprogram laboratory operated by the Associated Universities, Inc., (AUI) for DOE. The purpose of the assessment was to provide the status of environment, safety, and health (ES H) programs at the laboratory. The scope of the assessment included a review of management systems and operating procedures and records; observations of facility operations; and interviews at the facilities. Subteams in four areas performed the review: ES H, Occupational Safety and Health, and Management and Organization. The assessment was comprehensive, covering all areas of ES H activities and waste management operations. Compliance with applicable Federal, State, and local regulations; applicable DOE Orders; and internal BNL requirements was assessed. In addition, the assessment included an evaluation of the adequacy and effectiveness of the DOE and the site contractor, Associated Universities, Inc. (AUI), management, organization, and administration of the ES H programs at BNL. This volume contains appendices.

  12. Tiger Team assessment of the Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    This report documents the results of the Department of Energy's (DOE's) Tiger Team Assessment conducted at Brookhaven National Laboratory (BNL) in Upton, New York, between March 26 and April 27, 1990. The BNL is a multiprogram laboratory operated by the Associated Universities, Inc., (AUI) for DOE. The purpose of the assessment was to provide the status of environment, safety, and health (ES H) programs at the Laboratory. The scope of the assessment included a review of management systems and operating procedures and records; observations of facility operations; and interviews at the facilities. Subteams in four areas performed the review: ES H, Occupational Safety and Health, and Management and Organization. The assessment was comprehensive, covering all areas of ES H activities and waste management operations. Compliance with applicable Federal, State, and local regulations; applicable DOE Orders; and internal BNL requirements was assessed. In addition, the assessment included an evaluation of the adequacy and effectiveness of the DOE and the site contractor, Associated Universities, Inc. (AUI), management, organization, and administration of the ES H programs at BNL.

  13. Brookhaven: Ready for RHIC

    International Nuclear Information System (INIS)

    Ludlam, Tom

    1990-01-01

    With its RHIC - Relativistic Heavy Ion Collider - project now part of the budget proposed by US President Bush for fiscal year 1991, Brookhaven is about to start construction of a unique kind of high energy collider. At a time when accelerators handling particles - electrons, protons and their antimatter counterparts - are boosting beam energies for microscopes to probe evershorter distances, RHIC is envisioned as a great pressure-cooker for strongly interacting matter

  14. Brookhaven: Ready for RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Ludlam, Tom

    1990-04-15

    With its RHIC - Relativistic Heavy Ion Collider - project now part of the budget proposed by US President Bush for fiscal year 1991, Brookhaven is about to start construction of a unique kind of high energy collider. At a time when accelerators handling particles - electrons, protons and their antimatter counterparts - are boosting beam energies for microscopes to probe evershorter distances, RHIC is envisioned as a great pressure-cooker for strongly interacting matter.

  15. Brookhaven highlights, October 1979-September 1980

    International Nuclear Information System (INIS)

    1980-01-01

    Highlights are given for the research areas of the Brookhaven National Laboratory. These areas include high energy physics, physics and chemistry, life sciences, applied energy science (energy and environment, and nuclear energy), and support activities (including mathematics, instrumentation, reactors, and safety)

  16. BROOKHAVEN: Spin rotator to boost polarization

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    The Alternating Gradient Synchrotron (AGS) at Brookhaven holds the world record energy for spin polarized proton beams at 22 GeV. However this required a complicated two-week commissioning effort to overcome 39 imperfection depolarizing resonances and six intrinsic depolarizing resonances

  17. Brookhaven highlights, October 1979-September 1980

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    Highlights are given for the research areas of the Brookhaven National Laboratory. These areas include high energy physics, physics and chemistry, life sciences, applied energy science (energy and environment, and nuclear energy), and support activities (including mathematics, instrumentation, reactors, and safety). (GHT)

  18. The Brookhaven Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Fernow, R.C.; Fischer, J.; Fisher, A.S.; Gallardo, J.; Jialin, Xie; Kirk, H.G.; Parsa, Z.; Palmer, R.B.; Rao, T.; Rogers, J.; Sheehan, J.; Tsang, T.Y.F.; Ulc, S.; Van Steenbergen, A.; Woodle, M.; Zhang, R.S.; McDonald, K.T.; Russell, D.P.; Jiang, Z.Y.; Pellegrini, C.; Wang, X.J.

    1990-01-01

    The Accelerator Test Facility (ATF), presently under construction at Brookhaven National laboratory, is described. It consists of a 50-MeV electron beam synchronizable to a high-peak power CO 2 laser. The interaction of electrons with the laser field will be probed, with some emphasis on exploring laser-based acceleration techniques. 5 refs., 2 figs

  19. BROOKHAVEN: Japanese collaboration

    International Nuclear Information System (INIS)

    Thieberger, Peter

    1995-01-01

    Full text: The Japanese RIKEN Laboratory is contributing $20 million to help construct the RHIC Relativistic Heavy Ion Collider now being built at Brookhaven and due to be completed in 1999. In return, RIKEN will participate in research at RHIC. RHIC is being built to collide beams of heavy ions at energies of about 100 GeV per nucleon to explore hot and dense states of nuclear matter, with the ultimate aim of finding the quark-gluon plasma, the medium which existed in the fiery aftermath of the Big Bang before subsequently 'freezing' into nucleons. However another long-time Brookhaven speciality is handling beams of polarized (spin-oriented) protons in the 30 GeV AGS Alternating Gradient Synchrotron, which will act as the injector for RHIC. With the involvement of RIKEN, the RHIC programme now expands to cover polarized protons. Half of the RIKEN support will be used to build and install the special hardware needed to handle the polarized beams in RHIC. This includes 'Siberian Snakes' to negotiate depolarizing resonances which would otherwise mar beam acceleration (September 1994, page 27). The remaining RIKEN funding will go towards additional equipment for the PHENIX detector (May 1992, page 10) to enable it to cover spin physics. This equipment includes a second muon arm, with a magnet and tracking chamber. A multidisciplinary laboratory, RIKEN - Rikagaku Kenkyusho, or the Institute of Physical and Chemical Research - near Tokyo is currently the scene of construction of an 8 GeV synchrotron X-ray source

  20. Brookhaven National Laboratory site environmental report for calendar year 1990

    International Nuclear Information System (INIS)

    Miltenberger, R.P.; Royce, B.A.; Naidu, J.R.

    1992-01-01

    Brookhaven National Laboratory (BNL) carries out basic and applied research in the following fields: high-energy nuclear and solid state physics; fundamental material and structure properties and the interactions of matter; nuclear medicine, biomedical and environmental sciences; and selected energy technologies. In conducting these research activities, it is Laboratory policy to protect the health and safety of employees and the public, and to minimize the impact of BNL operations on the environment. This document is the BNL environmental report for the calendar year 1990 for the safety and Environmental Protection division and corners topics on effluents, surveillance, regulations, assessments, and compliance

  1. Brookhaven National Laboratory site environmental report for calendar year 1990

    Energy Technology Data Exchange (ETDEWEB)

    Miltenberger, R.P.; Royce, B.A.; Naidu, J.R.

    1992-01-01

    Brookhaven National Laboratory (BNL) carries out basic and applied research in the following fields: high-energy nuclear and solid state physics; fundamental material and structure properties and the interactions of matter; nuclear medicine, biomedical and environmental sciences; and selected energy technologies. In conducting these research activities, it is Laboratory policy to protect the health and safety of employees and the public, and to minimize the impact of BNL operations on the environment. This document is the BNL environmental report for the calendar year 1990 for the safety and Environmental Protection division and corners topics on effluents, surveillance, regulations, assessments, and compliance.

  2. New Brookhaven chief seeks cross-cutting research

    CERN Multimedia

    Jones, D

    2003-01-01

    Brookhaven National Laboratory will pursue opportunities for promoting commercial development of energy systems and other technologies while focusing on the lab's primary mission of basic science research, according to the incoming BNL director, Praveen Chaudhari (1 page).

  3. Brookhaven highlights, October 1, 1989--September 30, 1990

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, M.S.; Cohen, A.; Greenberg, D.; Seubert, L.; Kuper, J.B.H. (eds.)

    1990-01-01

    This report discusses research being conducted at Brookhaven National Laboratory. Highlights from all the department are illustrated. The main topics are on accelerator development and applications. (LSP)

  4. Applied programs at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    This document overviews the areas of current research at Brookhaven National Laboratory. Technology transfer and the user facilities are discussed. Current topics are presented in the areas of applied physics, chemical science, material science, energy efficiency and conservation, environmental health and mathematics, biosystems and process science, oceanography, and nuclear energy. (GHH)

  5. The Phase I/II BNCT Trials at the Brookhaven medical research reactor: Critical considerations

    International Nuclear Information System (INIS)

    Diaz, A.Z.

    2001-01-01

    A phase I/II clinical trial of boronophenylalanine-fructose (BPA-F) mediated boron neutron capture therapy (BNCT) for Glioblastoma Multiforme (GBM) was initiated at Brookhaven National Laboratory (BNL) in 1994. Many critical issues were considered during the design of the first of many sequential dose escalation protocols. These critical issues included patient selection criteria, boron delivery agent, dose limits to the normal brain, dose escalation schemes for both neutron exposure and boron dose, and fractionation. As the clinical protocols progressed and evaluation of the tolerance of the central nervous system (CNS) to BPA-mediated BNCT at the BMRR continued new specifications were adopted. Clinical data reflecting the progression of the protocols will be presented to illustrate the steps taken and the reasons behind their adoption. (author)

  6. Brookhaven National Laboratory site environmental report for calendar year 1991

    International Nuclear Information System (INIS)

    Naidu, J.R.; Royce, B.A.; Miltenberger, R.P.

    1992-09-01

    This publication presents the results of BNL's environmental monitoring and compliance effort and provides an assessment of the impact of Brookhaven National Laboratory (BNL) operations on the environment. This document is the responsibility of the Environmental Protection Section of the Safety and Envirorunental Protection Division. Within this Section, the Environmental Monitoring Group (EMG) sample the environment, interpreted the results, performed the impact analysis of the emissions from BNL, and compiled the information presented here. In this effort, other groups of the Section: Compliance; Analytical; Ground Water; and Quality played a key role in addressing the regulatory aspects and the analysis and documentation of the data, respectively

  7. Brookhaven National Laboratory site environmental report for calendar year 1991

    Energy Technology Data Exchange (ETDEWEB)

    Naidu, J.R.; Royce, B.A.; Miltenberger, R.P.

    1992-09-01

    This publication presents the results of BNL's environmental monitoring and compliance effort and provides an assessment of the impact of Brookhaven National Laboratory (BNL) operations on the environment. This document is the responsibility of the Environmental Protection Section of the Safety and Envirorunental Protection Division. Within this Section, the Environmental Monitoring Group (EMG) sample the environment, interpreted the results, performed the impact analysis of the emissions from BNL, and compiled the information presented here. In this effort, other groups of the Section: Compliance; Analytical; Ground Water; and Quality played a key role in addressing the regulatory aspects and the analysis and documentation of the data, respectively.

  8. Brookhaven National Laboratory site environmental report for calendar year 1991

    Energy Technology Data Exchange (ETDEWEB)

    Naidu, J.R.; Royce, B.A.; Miltenberger, R.P.

    1992-09-01

    This publication presents the results of BNL`s environmental monitoring and compliance effort and provides an assessment of the impact of Brookhaven National Laboratory (BNL) operations on the environment. This document is the responsibility of the Environmental Protection Section of the Safety and Envirorunental Protection Division. Within this Section, the Environmental Monitoring Group (EMG) sample the environment, interpreted the results, performed the impact analysis of the emissions from BNL, and compiled the information presented here. In this effort, other groups of the Section: Compliance; Analytical; Ground Water; and Quality played a key role in addressing the regulatory aspects and the analysis and documentation of the data, respectively.

  9. A woman like you: Women scientists and engineers at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Benkovitz, Carmen; Bernholc, Nicole; Cohen, Anita; Eng, Susan; Enriquez-Leder, Rosario; Franz, Barbara; Gorden, Patricia; Hanson, Louise; Lamble, Geraldine; Martin, Harriet; Mastrangelo, Iris; McLane, Victoria; Villela, Maria-Alicia; Vivirito, Katherine; Woodhead, Avril

    1991-01-01

    This publication by the women in Science and Engineering introduces career possibilities in science and engineering. It introduces what work and home life are like for women who have already entered these fields. Women at Brookhaven National Laboratory work in a variety of challenging research roles -- from biologist and environmental scientist to safety engineer, from patent lawyer to technician. Brookhaven National Laboratory is a multi-program laboratory which carries out basic and applied research in the physical, biomedical and environmental sciences and in selected energy technologies. The Laboratory is managed by Associated University, Inc., under contract with the US Department of Energy. Brookhaven and the other national laboratories, because of their enormous research resources, can play a critical role in a education and training of the workforce.

  10. The Brookhaven Radiation Effects Facility

    Energy Technology Data Exchange (ETDEWEB)

    Grand, P.; Snead, C.L.; Ward, T.

    1988-01-01

    The Neutral Particle Beam (NPB) Radiation Effects Facility (REF), funded by the Strategic Defense Initiative Office (SDIO) through the Defense Nuclear Agency (DNA) and the Air Force Weapons Laboratory (AFWL), has been constructed at Brookhaven National Laboratory (BNL). Operation started in October 1986. The facility is capable of delivering pulsed H{sup -}, H{sup o}, and H{sup +} beams of 100 to 200 MeV energy up to 30 mA peak current. Pulses can be adjusted from 5 {mu}s to 500 {mu}s length at a repetition rate of 5 pps. The beam spot on target is adjustable from 3 to 100 cm diameter (2 {sigma}) resulting in a maximum dose of about 10 MRads (Si) per pulse (small beam spot). Experimental use of the REF is being primarily supported by the SDI lethality (LTH-4) program. The program has addressed ionization effects in electronics, both dose rate and total dose dependence, radiation-sensitive components, and dE/dx effects in energetic materials including propellants and high explosives (HE). This paper describes the facility, its capabilities and potential, and the experiments that have been carried out to date or are being planned. 2 refs., 10 figs.

  11. The Brookhaven Radiation Effects Facility

    International Nuclear Information System (INIS)

    Grand, P.; Snead, C.L.; Ward, T.

    1988-01-01

    The Neutral Particle Beam (NPB) Radiation Effects Facility (REF), funded by the Strategic Defense Initiative Office (SDIO) through the Defense Nuclear Agency (DNA) and the Air Force Weapons Laboratory (AFWL), has been constructed at Brookhaven National Laboratory (BNL). Operation started in October 1986. The facility is capable of delivering pulsed H - , H/sup o/, and H + beams of 100 to 200 MeV energy up to 30 mA peak current. Pulses can be adjusted from 5 μs to 500 μs length at a repetition rate of 5 pps. The beam spot on target is adjustable from 3 to 100 cm diameter (2 σ) resulting in a maximum dose of about 10 MRads (Si) per pulse (small beam spot). Experimental use of the REF is being primarily supported by the SDI lethality (LTH-4) program. The program has addressed ionization effects in electronics, both dose rate and total dose dependence, radiation-sensitive components, and dE/dx effects in energetic materials including propellants and high explosives (HE). This paper describes the facility, its capabilities and potential, and the experiments that have been carried out to date or are being planned. 2 refs., 10 figs

  12. The Amtex DAMA Project: The Brookhaven contribution

    Energy Technology Data Exchange (ETDEWEB)

    Peskin, A.M.

    1995-01-01

    The Amtex Partnership organized in 1993 as a Technology Transfer Collaboration among members of the integrated textile industry, the DOE National Laboratories, a number of universities, and several research/education/technology transfer organizations (RETTs). Under the Amtex umbrella organization, a number of technology areas were defined and individual projects were launched addressing various aspects of improving the health and competitiveness of the American textile industry. The first and, to date, the largest of these has been the computer-based Demand Activated Manufacturing Architecture (DAMA) project. Brookhaven National Laboratory became involved in DAMA beginning in March of 1993 and remained an active participant through January of 1995. It was staffed almost exclusively with personnel of the Computing and Communications Division. This document summarizes the activities and accomplishments of the Brookhaven team in working with the larger collaboration. Detailed information about the Amtex Partnership, the DAMA Project, and specific BNL contributions are documented elsewhere.

  13. The Brookhaven electron analogue, 1953--1957

    Energy Technology Data Exchange (ETDEWEB)

    Plotkin, M.

    1991-12-18

    The following topics are discussed on the Brookhaven electron analogue: L.J. Haworth and E.L. VanHorn letters; Original G.K. Green outline for report; General description; Parameter list; Mechanical Assembly; Alignment; Degaussing; Vacuum System; Injection System; The pulsed inflector; RF System; Ferrite Cavity; Pick-up electrodes and preamplifiers; Radio Frequency power amplifier; Lens supply; Controls and Power; and RF acceleration summary.

  14. The Brookhaven electron analogue, 1953--1957

    International Nuclear Information System (INIS)

    Plotkin, M.

    1991-01-01

    The following topics are discussed on the Brookhaven electron analogue: L.J. Haworth and E.L. VanHorn letters; Original G.K. Green outline for report; General description; Parameter list; Mechanical Assembly; Alignment; Degaussing; Vacuum System; Injection System; The pulsed inflector; RF System; Ferrite Cavity; Pick-up electrodes and preamplifiers; Radio Frequency power amplifier; Lens supply; Controls and Power; and RF acceleration summary

  15. Development of H- sources at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Prelec, K.

    1977-01-01

    Negative hydrogen ion sources have been developed at Brookhaven National Laboratory for several years, with the initial goal to design a source for accelerator applications and later on to design a large unit for applications in neutral beam injectors of magnetic fusion devices. Three types of sources were investigated, a hollow discharge duoplasmatron yielding H - currents up to 60 mA, a Penning source yielding H - currents up to 440 mA, and a magnetron source yielding H - currents up to 1 A. All sources operate with a mixture of hydrogen gas and cesium vapors, and H - ions are most likely produced on cesium covered electrode surfaces. A larger model of a Penning/magnetron source was constructed and will be tested soon; it incorporates among other new features a system for the cooling of the cathode

  16. Beam vacuum system of Brookhaven's muon storage ring

    International Nuclear Information System (INIS)

    Hseuth, H.C.; Snydstrup, L.; Mapes, M.

    1995-01-01

    A storage ring with a circumference of 45 m is being built at Brookhaven to measure the g-2 value of the muons to an accuracy of 0.35 ppm.. The beam vacuum system of the storage ring will operate at 10 -7 Torr and has to be completely non-magnetic. It consists of twelve sector chambers. The chambers are constructed of aluminum and are approximately 3.5 m in length with a rectangular cross-section of 16.5 cm high by 45 cm at the widest point. The design features, fabrication techniques and cleaning methods for these chambers are described. The beam vacuum system will be pumped by forty eight non-magnetic distributed ion pumps with a total pumping speed of over 2000 ell/sec. Monte Carlo simulations of the pressure distribution in the muon storage region are presented

  17. BROOKHAVEN: Booster boost

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    After three months of intensive dedicated machine studies, Brookhaven's new Booster accelerated 5 x 10 13 protons over four cycles, about 85% of the design intensity. This was made possible by careful matching of Linac beam into the Booster and by extensive resonance stop band corrections implemented during Booster acceleration. The best single cycle injection into the AGS Alternating Gradient Synchrotron was 1.14 x 10 13 protons from the Booster. 1.05 x 10 13 protons were kept in the AGS, a 92% combined efficiency of extraction, transfer, and injection. The maximum injected 1994 shutdown period, enabling the 1994 physics run to make use of the full Booster intensity and go for the stated AGS objective of 4x10 13 protons per pulse

  18. Video Games - Did They Begin at Brookhaven

    Science.gov (United States)

    dropdown arrow Site Map A-Z Index Menu Synopsis Video Games – Did They Begin at Brookhaven? Additional Web program led to the pioneering development of video games. William Higinbotham William Higinbotham First Pong, now Space Invaders, next Star Castle – video games have mesmerized children of at all ages

  19. Epithermal neutron beam design for neutron capture therapy at the Power Burst Facility and the Brookhaven Medical Research Reactor

    International Nuclear Information System (INIS)

    Wheeler, F.J.; Parsons, D.K.; Rushton, B.L.; Nigg, D.W.

    1990-01-01

    Nuclear design studies have been performed for two reactor-based epithermal neutron beams for cancer treatment by neutron capture therapy (NCT). An intermediate-intensity epithermal beam has been designed and implemented at the Brookhaven Medical Research Reactor (BMRR). Measurements show that the BMRR design predictions for the principal characteristics of this beam are accurate. A canine program for research into the biological effects of NCT is now under way at BMRR. The design for a high-intensity epithermal beam with minimal contamination from undesirable radiation components has been finalized for the Power Burst Facility (PBF) at the Idaho National Engineering Laboratory. This design will be implemented when it is determined that human NCT trials are advisable. The PBF beam will exhibit approximately an order of magnitude improvement in absolute epithermal flux intensity over that available in the BMRR, and its angular distribution and spectral characteristics will be more advantageous for NCT. The combined effects of beam intensity, angular distribution, spectrum, and contaminant level allow the desired tumor radiation dose to be delivered in much shorter times than are possible with the currently available BMRR beam, with a significant reduction (factor of 3 to 5) in collateral dose due to beam contaminants

  20. Synchrotron radiation applications in medical research at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Thomlinson, W.

    1997-08-01

    In the relatively short time that synchrotrons have been available to the scientific community, their characteristic beams of UV and X-ray radiation have been applied to virtually all areas of medical science which use ionizing radiation. The ability to tune intense monochromatic beams over wide energy ranges clearly differentiates these sources from standard clinical and research tools. The tunable spectrum, high intrinsic collimation of the beams, polarization and intensity of the beams make possible in-vitro and in-vivo research and therapeutic programs not otherwise possible. From the beginning of research operation at the National Synchrotron Light Source (NSLS), many programs have been carrying out basic biomedical research. At first, the research was limited to in-vitro programs such as the x-ray microscope, circular dichroism, XAFS, protein crystallography, micro-tomography and fluorescence analysis. Later, as the coronary angiography program made plans to move its experimental phase from SSRL to the NSLS, it became clear that other in-vivo projects could also be carried out at the synchrotron. The development of SMERF (Synchrotron Medical Research Facility) on beamline X17 became the home not only for angiography but also for the MECT (Multiple Energy Computed Tomography) project for cerebral and vascular imaging. The high energy spectrum on X17 is necessary for the MRT (Microplanar Radiation Therapy) experiments. Experience with these programs and the existence of the Medical Programs Group at the NSLS led to the development of a program in synchrotron based mammography. A recent adaptation of the angiography hardware has made it possible to image human lungs (bronchography). Fig. 1 schematically depicts the broad range of active programs at the NSLS

  1. Accelerator timing at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Oerter, B.; Conkling, C.R.

    1995-01-01

    Accelerator timing at Brookhaven National Laboratory has evolved from multiple coaxial cables transmitting individual pulses in the original Alternating Gradient Synchrotron (AGS) design, to serial coded transmission as the AGS Booster was added. With the implementation of this technology, the Super Cycle Generator (SCG) which synchronizes the AGS, Booster, LINAC, and Tandem accelerators was introduced. This paper will describe the timing system being developed for the Relativistic Heavy Ion Collider (RHIC)

  2. From heavy ions to light sources at Brookhaven

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The Brookhaven National Laboratory, recovered from the debacle of the cancelled CBA proton-proton collider project, is now more than busy with an excellent physics programme at the 33 GeV Alternating Gradient Synchrotron and with solid projects for the years to come. (orig.).

  3. Vertical velocity variances and Reynold stresses at Brookhaven

    DEFF Research Database (Denmark)

    Busch, Niels E.; Brown, R.M.; Frizzola, J.A.

    1970-01-01

    Results of wind tunnel tests of the Brookhaven annular bivane are presented. The energy transfer functions describing the instrument response and the numerical filter employed in the data reduction process have been used to obtain corrected values of the normalized variance of the vertical wind v...

  4. Proposed Brookhaven accelerator-based neutron generator

    International Nuclear Information System (INIS)

    Grand, P.; Batchelor, K.; Chasman, R.; Rheaume, R.

    1976-01-01

    The d-Li Neutron Source concept, which includes a high-current dueteron linac, is an outgrowth of attempts made to use the BNL, 200-MeV proton linac BLIP facility to do radiation damage studies. It included a 100 mA, 30-MeV deuteron linear accelerator and a fast-flowing liquid lithium jet as the target. The latest design is not very different, except that the current is now 200 mA and the linac energy has been raised to 35 MeV. Both parameters, were changed to optimize the effectiveness of the facility with respect to flux, experimental volume and match to 14 MeV neutron-radiation-damage effects. The proposed Brookhaven Accelerator-based Neutron Generator is described with particular emphasis on the linear accelerator. The proposed facility is a practical and efficient way of producing the intense, high energy neutron beams needed for CTR material studies. The accelerator and liquid-metal technologies are well proven, state-of-the-art technologies. The fact that no new technology is required guarantees the possibility of meeting construction schedules, and more importantly, guarantees a high level of operational reliability

  5. Late medical consequences of exposure to radioactive fallout

    International Nuclear Information System (INIS)

    Adams, W.H.

    1992-01-01

    Data collected by the Brookhaven Medical Program on the late medical consequences of the exposure to radioactive fallout originated from the detonation of a thermonuclear device on Bikini atoll in Marshall Islands are discussed. (author) 23 refs.; 6 figs.; 9 tabs

  6. Constraining Anomaly Mediated Supersymmetry Breaking Framework via Ongoing Muon g-2 Experiment at Brookhaven

    CERN Document Server

    Chattopadhyay, U; Roy, S; PH; Chattopadhyay, Utpal; Ghosh, Dilip Kumar; Roy, Sourov

    2000-01-01

    The ongoing high precision E821 Brookhaven National Laboratory experiment on muon g-2 is promising to probe a theory involving supersymmetry. We have studied the constraints on minimal Anomaly Mediated Supersymmetry Breaking (AMSB) model using the current data of muon g-2 from Brookhaven. A scenario of seeing no deviation from the Standard Model is also considered, within $2\\sigma$ limit of the combined error from the Standard Model result and the Brookhaven predicted uncertainty level. The resulting constraint is found to be complementary to what one obtains from $b \\to s+ \\gamma$ bounds within the AMSB scenario, since only a definite sign of $\\mu$ is effectively probed via $b \\to s+ \\gamma$. A few relevant generic features of the model are also described for disallowed regions of the parameter space.

  7. Brookhaven highlights, October 1978-September 1979. [October 1978 to September 1979

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    These highlights present an overview of the major research and development achievements at Brookhaven National Laboratory from October 1978 to September 1979. Specific areas covered include: accelerator and high energy physics programs; high energy physics research; the AGS and improvements to the AGS; neutral beam development; heavy ion fusion; superconducting power cables; ISABELLE storage rings; the BNL Tandem accelerator; heavy ion experiments at the Tandem; the High Flux Beam Reactor; medium energy physics; nuclear theory; atomic and applied physics; solid state physics; neutron scattering studies; x-ray scattering studies; solid state theory; defects and disorder in solids; surface physics; the National Synchrotron Light Source ; Chemistry Department; Biology Department; Medical Department; energy sciences; environmental sciences; energy technology programs; National Center for Analysis of Energy Systems; advanced reactor systems; nuclear safety; National Nuclear Data Center; nuclear materials safeguards; Applied Mathematics Department; and support activities. (GHT)

  8. Brookhaven National Laboratory moves to the fast lane

    CERN Multimedia

    2006-01-01

    "The U.S. Department of Energy's energy sciences network (ESnet) continues to roll out its next-generation architecture on schedule with the March 14 completion of the Long Island Metropolitan Area Network, connecting Brookhaven National Laboratory (BNL) to the ESnet point of presente (PO) 60 miles away in New York City." (1 page)

  9. Database activities at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Trahern, C.G.

    1995-01-01

    Brookhaven National Laboratory is a multi-disciplinary lab in the DOE system of research laboratories. Database activities are correspondingly diverse within the restrictions imposed by the dominant relational database paradigm. The authors discuss related activities and tools used in RHIC and in the other major projects at BNL. The others are the Protein Data Bank being maintained by the Chemistry department, and a Geographical Information System (GIS)--a Superfund sponsored environmental monitoring project under development in the Office of Environmental Restoration

  10. Summary update of the Brookhaven tritium toxicity program with emphasis on recent cytogenetic and lifetime-shortening studies

    International Nuclear Information System (INIS)

    Carsten, A.L.; Benz, R.D.; Hughes, W.P.; Ichimasa, Yusuke; Ikushima, Takaji; Tezuka, Hideo.

    1988-01-01

    A number of years ago a multiparameter program to evaluate the toxicity of tritiated water (HTO) was undertaken in the Medical Department at Brookhaven National Laboratory. The results of most of these studies have been published and will receive brief attention. Emphasis will be placed on the unpublished studies involving the induction of sister chromatid exchanges (SCE's) in bone marrow of mice, new biochemical information, and preliminary results on lifetime-shortening and carcinogenesis. In brief, male Hale-Stoner Brookhaven (HSB) mice maintained on HTO concentrations ranging from 3.0 to 30.0 μCi/ml exhibited essentially the same number of SCE's per cell throughout their lifetime. Control mice showed a decrease in number of SCE's with age. The lack of a dose-response effect and the constant level of SCE's in HTO mice as compared to controls will be discussed. In the carcinogenesis study C57BL/6J male mice received various x-ray or HTO regimens. Mortality data from these and other studies in which CBA/Ca/BNL mice received single x-ray exposures or equivalent integrated dose exposures by single HTO injections will be discussed. 25 refs., 4 figs

  11. Deriving cleanup guidelines for radionuclides at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1997-01-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL`s Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory. With the exception of radium, there are no regulations or guidelines to establish cleanup guidelines for radionuclides in soils at BNL. BNL must derive radionuclide soil cleanup guidelines for a number of Operable Units (OUs) and Areas of Concern (AOCs). These guidelines are required by DOE under a proposed regulation for radiation protection of public health and the environment as well as to satisfy the requirements of CERCLA. The objective of this report is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL. Implementation of the approach is briefly discussed.

  12. Deriving cleanup guidelines for radionuclides at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1997-01-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL's Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory. With the exception of radium, there are no regulations or guidelines to establish cleanup guidelines for radionuclides in soils at BNL. BNL must derive radionuclide soil cleanup guidelines for a number of Operable Units (OUs) and Areas of Concern (AOCs). These guidelines are required by DOE under a proposed regulation for radiation protection of public health and the environment as well as to satisfy the requirements of CERCLA. The objective of this report is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL. Implementation of the approach is briefly discussed

  13. A woman like you: Women scientists and engineers at Brookhaven National Laboratory. Careers in action

    Energy Technology Data Exchange (ETDEWEB)

    1991-12-31

    This publication by the women in Science and Engineering introduces career possibilities in science and engineering. It introduces what work and home life are like for women who have already entered these fields. Women at Brookhaven National Laboratory work in a variety of challenging research roles -- from biologist and environmental scientist to safety engineer, from patent lawyer to technician. Brookhaven National Laboratory is a multi-program laboratory which carries out basic and applied research in the physical, biomedical and environmental sciences and in selected energy technologies. The Laboratory is managed by Associated University, Inc., under contract with the US Department of Energy. Brookhaven and the other national laboratories, because of their enormous research resources, can play a critical role in a education and training of the workforce.

  14. Searching for the H dibaryon at Brookhaven

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, A.J. [Princeton Univ., NJ (United States)

    1994-12-01

    This paper reviews the status of current experiments at Brookhaven, searching for the six-quark H dibaryon postulated by R. Jaffe in 1977. Two experiments, E813 and E888, have recently completed running and two new experiments, E836 and E885, are approved to run. The data recorded so far is under analysis and should have good sensitivity to both short-lived and long-lived Hs.

  15. Rebuilding the Brookhaven high flux beam reactor: A feasibility study

    International Nuclear Information System (INIS)

    Brynda, W.J.; Passell, L.; Rorer, D.C.

    1995-01-01

    After nearly thirty years of operation, Brookhaven's High Flux Beam Reactor (HFBR) is still one of the world's premier steady-state neutron sources. A major center for condensed matter studies, it currently supports fifteen separate beamlines conducting research in fields as diverse as crystallography, solid-state, nuclear and surface physics, polymer physics and structural biology and will very likely be able to do so for perhaps another decade. But beyond that point the HFBR will be running on borrowed time. Unless appropriate remedial action is taken, progressive radiation-induced embrittlement problems will eventually shut it down. Recognizing the HFBR's value as a national scientific resource, members of the Laboratory's scientific and reactor operations staffs began earlier this year to consider what could be done both to extend its useful life and to assure that it continues to provide state-of-the-art research facilities for the scientific community. This report summarizes the findings of that study. It addresses two basic issues: (i) identification and replacement of lifetime-limiting components and (ii) modifications and additions that could expand and enhance the reactor's research capabilities

  16. Description of the intense, low energy, monoenergetic positron beam at Brookhaven

    International Nuclear Information System (INIS)

    Lynn, K.G.; Mills, A.P. Jr.; Roellig, L.O.; Weber, M.

    1985-01-01

    An intense (4 x 10 7 s -1 ), low energy (approx. =1.0 eV), monoenergetic (ΔE approx. = 75 MeV) beam of positrons has been built at the Brookhaven National Laboratory. This flux is more than 10 times greater than any existing beam from radioactive sources. Plans are underway to increase further the flux by more than an order of magnitude. The intense low energy positron beam is made by utilizing the High Flux Beam Reactor at Brookhaven to produce the isotope 64 Cu with an activity of 40 curies of positrons. Source moderation techniques are utilized to produce the low energy positron beam from the high energy positrons emitted from 64 Cu. 31 refs., 7 figs

  17. Summer school in nuclear and radiochemistry at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Kolsky, K.L.

    2005-01-01

    The U.S. Department of Energy supports 24 fellowships for students to attend six-week programs at either San Jose State University in California, or Brookhaven National Laboratory (BNL) in New York. The American Chemical Society through the Division of Nuclear Science and Technology operates both schools. The twelve students at the BNL program are enrolled in the State University of New York at Stony Brook (SUNYSB) and receive 3 college credits for the lecture course (CHE-361) and 3 additional credits for the laboratory course (CHE-362). In addition to lectures and laboratories, students tour various nuclear facilities offsite, at BNL, and at SUNYSB. Opportunities are given the students to interact with faculty and scientists within the profession through the Guest Lecture Program. Further details are discussed along with results of student surveys for the years 1999 through 2002. (author)

  18. Relay testing at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.; Hofmayer, C.

    1989-01-01

    Brookhaven National Laboratory (BNL) is conducting a seismic test program on relays. The purpose of the test program is to investigate the influence of various designs, electrical and vibration parameters on the seismic capacity levels. The first series of testing has been completed and performed at Wyle Laboratories. The major part of the test program consisted of single axis, single frequency sine dwell tests. Random multiaxis, multifrequency tests were also performed. Highlights of the test results as well as a description of the testing methods are presented in this paper. 10 figs

  19. Decommissioning of the High Flux Beam Reactor at Brookhaven Lab

    Energy Technology Data Exchange (ETDEWEB)

    Hu, J. P. [Brookhaven National Lab. (BNL), Upton, NY (United States); Reciniello, R. N. [Brookhaven National Lab. (BNL), Upton, NY (United States); Holden, N. E. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2011-05-27

    The High Flux Beam Reactor at the Brookhaven National Laboratory was a heavy water cooled and moderated reactor that achieved criticality on October 31, 1965. It operated at a power level of 40 mega-watts. An equipment upgrade in 1982 allowed operations at 60 mega-watts. After a 1989 reactor shutdown to reanalyze safety impact of a hypothetical loss of coolant accident, the reactor was restarted in 1991 at 30 mega-watts. The HFBR was shutdown in December 1996 for routine maintenance and refueling. At that time, a leak of tritiated water was identified by routine sampling of ground water from wells located adjacent to the reactor’s spent fuel pool. The reactor remained shutdown for almost three years for safety and environmental reviews. In November 1999 the United States Department of Energy decided to permanently shutdown the HFBR. The decontamination and decommissioning of the HFBR complex, consisting of multiple structures and systems to operate and maintain the reactor, were complete in 2009 after removing and shipping off all the control rod blades. The emptied and cleaned HFBR dome which still contains the irradiated reactor vessel is presently under 24/7 surveillance for safety. Details of the HFBR cleanup conducted during 1999-2009 will be described in the paper.

  20. Medical supply on contingency military operations: experience from Operation GRITROCK.

    Science.gov (United States)

    Robinson, J P; Reeves, P

    2015-01-01

    Medical supply during military operations has the ability to affect the efficacy of the operation being undertaken, either negatively or positively. An appropriately-managed maritime platform with a robust medical supply chain during transit and on arrival in theatre is the main aim. A secure supply chain will reduce any implications that logistics may have with regard to capability, and negate the effects of deficiencies of short shelf life items occurring over time and during use in high tempo operations.

  1. Summary update of the Brookhaven tritium toxicity program with emphasis on recent cytogenetic and lifetime-shortening studies

    Energy Technology Data Exchange (ETDEWEB)

    Carsten, A.L.; Benz, R.D.; Hughes, W.P.; Ichimasa, Yusuke; Ikushima, Takaji; Tezuka, Hideo

    1988-01-01

    A number of years ago a multiparameter program to evaluate the toxicity of tritiated water (HTO) was undertaken in the Medical Department at Brookhaven National Laboratory. The results of most of these studies have been published and will receive brief attention. Emphasis will be placed on the unpublished studies involving the induction of sister chromatid exchanges (SCE's) in bone marrow of mice, new biochemical information, and preliminary results on lifetime-shortening and carcinogenesis. In brief, male Hale-Stoner Brookhaven (HSB) mice maintained on HTO concentrations ranging from 3.0 to 30.0 ..mu..Ci/ml exhibited essentially the same number of SCE's per cell throughout their lifetime. Control mice showed a decrease in number of SCE's with age. The lack of a dose-response effect and the constant level of SCE's in HTO mice as compared to controls will be discussed. In the carcinogenesis study C57BL/6J male mice received various x-ray or HTO regimens. Mortality data from these and other studies in which CBA/Ca/BNL mice received single x-ray exposures or equivalent integrated dose exposures by single HTO injections will be discussed. 25 refs., 4 figs.

  2. Brookhaven Lab and Argonne Lab scientists invent a plasma valve

    CERN Multimedia

    2003-01-01

    Scientists from Brookhaven National Laboratory and Argonne National Laboratory have received U.S. patent number 6,528,948 for a device that shuts off airflow into a vacuum about one million times faster than mechanical valves or shutters that are currently in use (1 page).

  3. The Doctrinal Basis for Medical Stability Operations

    Science.gov (United States)

    2010-01-01

    lead actor, preferably a HN agency, but sometimes the military must take the lead in medical stability operations when overwhelming violence prevents...34 Assessment Tasks Administration of hospital Communications Obstetrics , Pediatrics, Emergency room. Operating room Nursing procedures Medical supply

  4. Study of ν interactions at Brookhaven using counter techniques

    International Nuclear Information System (INIS)

    Williams, H.H.

    1977-01-01

    A review is presented of neutrino elastic scattering, νp → νp and anti νp → anti νp, as observed by the Harvard-Pennsylvania-Wisconsin (HPW) and Columbia-Illinois-Rockefeller (CIR) experiments at Brookhaven National Laboratory. Results from the CIR experiment on (anti) νN → (anti) νNπsup(o) are also discussed. (orig.) [de

  5. RHIC: What We Have Learned So Far (434th Brookhaven Lecture)

    International Nuclear Information System (INIS)

    O'Brien, Edward

    2008-01-01

    One of the world's premiere nuclear research facilities, the Relativistic Heavy Ion Collider (RHIC) at Brookhaven Lab is just completing its eighth year of physics operation. During the past eight years, RHIC's primary physics program has emphasized the creation, observation and explanation of nuclear matter created at temperatures and densities that last existed in the universe some 13.7 billion years ago. RHIC was built to study the strong force, which holds quarks and gluons together within the nucleus of an atom, with the goal of observing a plasma of quarks and gluons freed from the atomic nucleus. The new state of matter that was created, however, was quite different. Dr. O'Brien will discuss what RHIC scientists expected versus what they discovered, and how this finding both challenges existing theory and provides an opportunity to understand the strong force better.

  6. The first terawatt picosecond CO2 laser for advanced accelerator studies at the Brookhaven ATF

    International Nuclear Information System (INIS)

    Pogorelsky, I.V.; Ben-Zvi, I.; Skaritka, J.

    1996-10-01

    The first terawatt picosecond C0 2 laser system is under development at the Brookhaven Accelerator Test Facility. Presently operational 1 Joule 100-ps ATF laser will be upgraded with a 10 atm amplifier capable of delivery ∼ 15 Joules of laser energy in a 3 ps pulse. We describe the design of the x-ray preionized 10 atm amplifier of a 10 liter active volume energized by a 1 MV, 200 kA transverse electric discharge. The amplifier, equipped with internal optics, permits the accommodation of a regenerative stage and a multi-pass booster in a relatively compact single discharge volume. The ATF terawatt C0 2 laser shall become operational in 1997 to serve for laser acceleration, x-ray generation and other strong-field physics experiments

  7. Activities of the cross-section compilation and evaluation centers at the Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Chernick, J.

    1967-01-01

    The growth of the compilation and evaluation efforts at the Brookhaven National Laboratory are reviewed. The current work of the Sigma Center is discussed, including the status of the publication of supplements to BNL-325 and the current state of the SCISRS-I tape. Future needs for BNL-325 type publications and SCISRS-II cross-section tapes are outlined. The history of the Cross-Section Evaluation Center at the Brookhaven National Laboratory is similarly reviewed. The status of current work is discussed, including the growth of the ENDF/A tape. The status of US efforts to produce a cross-section tape (ENDF7B) at an early date to satisfy the needs of US reactor designers is discussed. The continued importance of integral experiments and their accurate analysis to provide checks of the cross-section tapes is pointed out. The role of the Brookhaven National Laboratory in collaboration on an international basis is reviewed, including its current relationship to the ENEA Neutron Data Compilation Centre, the International Atomic Energy Agency and other nuclear centres. (author)

  8. Increased intensity performance of the Brookhaven AGS

    International Nuclear Information System (INIS)

    Raka, E.; Ahrens, L.; Frey, W.; Gill, E.; Glenn, J.W.; Sanders, R.; Weng, W.

    1985-05-01

    With the advent of H - injection into the Brookhaven AGS, circulating beams of up to 3 x 10 13 protons at 200 MeV have been obtained. Rf capture of 2.2 x 10 13 and acceleration of 1.73 x 10 13 up to the transition energy (approx. = 8 GeV) and 1.64 x 10 13 to full energy (approx. = 29 GeV) has been achieved. This represents a 50% increase over the best performance obtained with H + injection. The increase in circulation beam current is obtained without filling the horizontal aperture. This allows the rf capture process to utilize a larger longitudinal phase space area (approx. = 1 eV sec/bunch vs less than or equal to 0.6 eV sec with H + operation). The resulting reduction in relative longitudinal density partially offsets the increase in space charge effects at higher currents. In order to make the capture process independent of injected beam current, a dynamic beam loading compensation loop was installed on the AGS rf system. This is the only addition to the synchrotron itself that was required to reach the new intensity records. A discussion of injection, the rf capture process, and space charge effects is presented. 9 refs., 5 figs

  9. Structural biology facilities at Brookhaven National Laboratory`s high flux beam reactor

    Energy Technology Data Exchange (ETDEWEB)

    Korszun, Z.R.; Saxena, A.M.; Schneider, D.K. [Brookhaven National Laboratory, Upton, NY (United States)

    1994-12-31

    The techniques for determining the structure of biological molecules and larger biological assemblies depend on the extent of order in the particular system. At the High Flux Beam Reactor at the Brookhaven National Laboratory, the Biology Department operates three beam lines dedicated to biological structure studies. These beam lines span the resolution range from approximately 700{Angstrom} to approximately 1.5{Angstrom} and are designed to perform structural studies on a wide range of biological systems. Beam line H3A is dedicated to single crystal diffraction studies of macromolecules, while beam line H3B is designed to study diffraction from partially ordered systems such as biological membranes. Beam line H9B is located on the cold source and is designed for small angle scattering experiments on oligomeric biological systems.

  10. The High Flux Beam Reactor at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Shapiro, S.M.

    1994-01-01

    Brookhaven National Laboratory's High Flux Beam Reactor (HFBR) was built because of the need of the scientist to always want 'more'. In the mid-50's the Brookhaven Graphite reactor was churning away producing a number of new results when the current generation of scientists, led by Donald Hughes, realized the need for a high flux reactor and started down the political, scientific and engineering path that led to the BFBR. The effort was joined by a number of engineers and scientists among them, Chemick, Hastings, Kouts, and Hendrie, who came up with the novel design of the HFBR. The two innovative features that have been incorporated in nearly all other research reactors built since are: (i) an under moderated core arrangement which enables the thermal flux to peak outside the core region where beam tubes can be placed, and (ii) beam tubes that are tangential to the core which decrease the fast neutron background without affecting the thermal beam intensity. Construction began in the fall of 1961 and four years later, at a cost of $12 Million, criticality was achieved on Halloween Night, 1965. Thus began 30 years of scientific accomplishments

  11. Summary of some work on high temperature superconductors at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Strongin, M.

    1987-01-01

    A summary is presented of recent high T/sub c/ superconductivity work by the Brookhaven staff. Significant work done by outside users on the major facilities is not discussed here. Theoretical work on mechanisms of superconductivity, is discussed separately elsewhere in this proceedings. The experimental work can be divided into two major categories; scattering and spectroscopy experiments at the Brookhaven facilities, and measurements of the macroscopic electrical and magnetic properties of the superconductors, as well as an additional contribution on sample preparation. An example of the complimentary nature of these techniques is shown for the case of penetration depth measurements, where the value of λ obtained using mu mesons as a microscopic probe of the internal fields is different than that obtained inductively. This difference leads to some insight into the inter-granular coupling

  12. The Quest for High Luminosity in Hadron Colliders (413th Brookhaven Lecture)

    International Nuclear Information System (INIS)

    Fischer, Wolfram

    2006-01-01

    In 1909, by bombarding a gold foil with alpha particles from a radioactive source, Ernest Rutherford and coworkers learned that the atom is made of a nucleus surrounded by an electron cloud. Ever since, scientists have been probing deeper and deeper into the structure of matter using the same technique. With increasingly powerful machines, they accelerate beams of particles to higher and higher energies, to penetrate more forcefully into the matter being investigated and reveal more about the contents and behavior of the unknown particle world. To achieve the highest collision energies, projectile particles must be as heavy as possible, and collide not with a fixed target but another beam traveling in the opposite direction. These experiments are done in machines called hadron colliders, which are some of the largest and most complex research tools in science. Five such machines have been built and operated, with Brookhaven's Relativistic Heavy Ion Collider (RHIC) currently the record holder for the total collision energy. One more such machine is under construction. Colliders have two vital performance parameters on which their success depends: one is their collision energy, and the other, the number of particle collisions they can produce, which is proportional to a quantity known as the luminosity. One of the tremendous achievements in the world's latest collider, RHIC, is the amazing luminosity that it produces in addition to its high energy. To learn about the performance evolution of these colliders and the way almost insurmountable difficulties can be overcome, especially in RHIC, join Wolfram Fischer, a physicist in the Collider-Accelerator (C-A) Department, who will give the next Brookhaven Lecture, on 'The Quest for High Luminosity in Hadron Colliders.'

  13. Brookhaven National Laboratory's multiparticle spectrometer drift chamber system

    International Nuclear Information System (INIS)

    Etkin, A.; Kramer, M.A.

    1979-01-01

    A system of drift chambers is being built to replace the present spark chambers in the Brookhaven National Laboratory's Multiparticle Spectrometer. This system will handle a beam of approx. 3 million particles per second and have a resolution of 200 μm. A summary of the status of the chambers and the custom integrated circuits is presented. The data acquisition system is described. Prototype chambers have been built and tested with results that are consistent with the expected chamber properties

  14. Scientists at Brookhaven contribute to the development of a better electron accelerator

    CERN Multimedia

    2004-01-01

    Scientists working at Brookhaven have developed a compact linear accelerator called STELLA (Staged Electron Laser Acceleration). Highly efficient, it may help electron accelerators become practical tools for applications in industry and medicine, such as radiation therapy (1 page)

  15. The Brookhaven ATF low-emittance beam line

    International Nuclear Information System (INIS)

    Wang, X.J.; Kirk, H.G.

    1991-01-01

    One component of the experimental program at the Brookhaven Accelerator Test Facility (ATF) consists of a class of experiments which will study the acceleration of electrons through micron-size structures which are exposed in coincidence to a 100 GW CO 2 laser beam. These experiments require the development and control of an electron beam with geometric emittances on the order of 10 -10 m-rad and intensities on the order of 10 6 electrons. In this paper, the authors describe the strategies for producing such beams and the effects of higher-order aberrations. Particle tracking results are presented for the final-focus system

  16. Polarized proton acceleration at the Brookhaven AGS

    International Nuclear Information System (INIS)

    Ahrens, L.A.

    1986-01-01

    At the conclusion of polarized proton commissioning in February 1986, protons with an average polarization of 45%, momentum of 21.7 GeV/c, and intensity of 2 x 10 10 protons per pulse, were extracted to an external polarimeter at the Brookhaven AGS. In order to maintain this polarization, five intrinsic and nearly forty imperfection depolarizing resonances had to be corrected. An apparent interaction between imperfection and intrinsic resonances occurring at very nearly the same energy was observed and the correction of imperfection resonances using ''beat'' magnetic harmonics discovered in the previous AGS commissioning run was further confirmed

  17. Brookhaven National Laboratory's Accelerator Test Facility: research highlights and plans

    Science.gov (United States)

    Pogorelsky, I. V.; Ben-Zvi, I.

    2014-08-01

    The Accelerator Test Facility (ATF) at Brookhaven National Laboratory has served as a user facility for accelerator science for over a quarter of a century. In fulfilling this mission, the ATF offers the unique combination of a high-brightness 80 MeV electron beam that is synchronized to a 1 TW picosecond CO2 laser. We unveil herein our plan to considerably expand the ATF's floor space with an upgrade of the electron beam's energy to 300 MeV and the CO2 laser's peak power to 100 TW. This upgrade will propel the ATF even further to the forefront of research on advanced accelerators and radiation sources, supporting the most innovative ideas in this field. We discuss emerging opportunities for scientific breakthroughs, including the following: plasma wakefield acceleration studies in research directions already active at the ATF; laser wakefield acceleration (LWFA), where the longer laser wavelengths are expected to engender a proportional increase in the beam's charge while our linac will assure, for the first time, the opportunity to undertake detailed studies of seeding and staging of the LWFA; proton acceleration to the 100-200 MeV level, which is essential for medical applications; and others.

  18. Neutron detector development at Brookhaven

    International Nuclear Information System (INIS)

    Yu, B.; Harder, J.A.; Mead, J.A.; Radeka, V.; Schaknowski, N.A.; Smith, G.C.

    2003-01-01

    Two-dimensional thermal neutron detectors have been the subject of research and development at Brookhaven for over 20 years. Based primarily on multi-wire chambers filled with a gas mixture containing 3 He, these detectors have been used in wide-ranging studies of molecular biology and material science samples. At each phase of development, experimenters have sought improvements in key parameters such as position resolution, counting rate, efficiency, solid-angle coverage and stability. A suite of detectors has been developed with sensitive areas ranging from 5x5 to 50x50 cm 2 . These devices incorporate low-noise-position readout and the best position resolution for thermal neutron gas detectors. Recent developments include a 1.5 mx20 cm detector containing multiple segments with continuously sensitive readout, and detectors with unity gain for ultra-high rate capability and long-term stability

  19. Decommissioning of the High Flux Beam Reactor at Brookhaven National Laboratory.

    Science.gov (United States)

    Hu, Jih-Perng; Reciniello, Richard N; Holden, Norman E

    2012-08-01

    The High Flux Beam Reactor (HFBR) at the Brookhaven National Laboratory was a heavy-water cooled and moderated reactor that achieved criticality on 31 October 1965. It operated at a power level of 40 mega-watts. An equipment upgrade in 1982 allowed operations at 60 mega-watts. After a 1989 reactor shutdown to reanalyze safety impact of a hypothetical loss of coolant accident, the reactor was restarted in 1991 at 30 mega-watts. The HFBR was shut down in December 1996 for routine maintenance and refueling. At that time, a leak of tritiated water was identified by routine sampling of ground water from wells located adjacent to the reactor's spent fuel pool. The reactor remained shut down for almost 3 y for safety and environmental reviews. In November 1999, the United States Department of Energy decided to permanently shut down the HFBR. The decontamination and decommissioning of the HFBR complex, consisting of multiple structures and systems to operate and maintain the reactor, were complete in 2009 after removing and shipping off all the control rod blades. The emptied and cleaned HFBR dome, which still contains the irradiated reactor vessel is presently under 24/7 surveillance for safety. Details of the HFBR's cleanup performed during 1999-2009, to allow the BNL facilities to be re-accessed by the public, will be described in the paper.

  20. WILDLAND FIRE MANAGEMENT PLAN FOR BROOKHAVEN NATIONAL LABORATORY.

    Energy Technology Data Exchange (ETDEWEB)

    ENVIRONMENTAL AND WASTE MANAGEMENT SERVICES DIVISION

    2003-09-01

    This Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) and the Upton Ecological and Research Reserve (Upton Reserve) is based on the U.S. Fish & Wildlife Service (FWS) fire management planning procedures and was developed in cooperation with the Department of Energy (DOE) by Brookhaven Science Associates. As the Upton Reserve is contained within the BNL 5,265-acre site, it is logical that the plan applies to both the Upton Reserve and BNL. The Department of the Interior policy for managing wildland fires requires that all areas managed by FWS that can sustain fire must have an FMP that details fire management guidelines for operational procedures and specifies values to be protected or enhanced. Fire management plans provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled, ''prescribed'' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL/Upton Reserve Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered and threatened species and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL and the Upton Reserve. This FMP will be reviewed periodically to ensure the fire program advances and evolves with the missions of FWS, BNL, and the Upton Reserve. This Fire Management Plan is a modified version of the Long Island National Wildlife Refuge Complex Fire plan (updated in 2000), which contains all FWS fire plan requirements and is presented in the format specified by the national template for fire management plans adopted under the National Fire Plan. The DOE is one of the signatory agencies on the National Fire Plan. FWS shall be, through an Interagency Agreement dated November 2000 (Appendix C), responsible for coordinating and

  1. Data acquisition system for Experiment E866 at the Brookhaven AGS

    International Nuclear Information System (INIS)

    Ashktorab, K.; LeVine, M.J.; Scheetz, R.A.

    1993-01-01

    Experiment E866 consists of two spectrometers and related detectors for investigations of collisions of relativistic beams of Au ions with fixed targets at the Brookhaven AGS. The data acquisition system, consisting of 11 CPUs in a single VME crate, gathers data from 8 Camac crates and 6 Fastbus crates

  2. Machine Protection System for Concurrent Operation of RHIC and BLIP

    CERN Document Server

    Wilinski, Michelle; Glenn, Joseph; Mausner, Leonard; Unger, Kerry

    2005-01-01

    The Brookhaven 200 MeV linac is a multipurpose machine used to inject low intensity polarized protons ultimately ending up in RHIC as well as to inject high intensity protons to BLIP, a medical isotope production facility. If high intensity protons were injected to RHIC by mistake, administrative radiation limits could be exceeded or sensitive electronics could be damaged. In the past, the changeover from polarized proton to high intensity proton operation has been a lengthy process, thereby never allowing the two programs to run simultaneously. To remedy this situation and allow for concurrent operation of RHIC and BLIP, an active interlock system has been designed to monitor current levels in the AGS using two current transformers with fail safe circuitry and associated electronics to inhibit beam to RHIC if high intensity is detected.

  3. Electronic Procedures for Medical Operations

    Science.gov (United States)

    2015-01-01

    Electronic procedures are replacing text-based documents for recording the steps in performing medical operations aboard the International Space Station. S&K Aerospace, LLC, has developed a content-based electronic system-based on the Extensible Markup Language (XML) standard-that separates text from formatting standards and tags items contained in procedures so they can be recognized by other electronic systems. For example, to change a standard format, electronic procedures are changed in a single batch process, and the entire body of procedures will have the new format. Procedures can be quickly searched to determine which are affected by software and hardware changes. Similarly, procedures are easily shared with other electronic systems. The system also enables real-time data capture and automatic bookmarking of current procedure steps. In Phase II of the project, S&K Aerospace developed a Procedure Representation Language (PRL) and tools to support the creation and maintenance of electronic procedures for medical operations. The goal is to develop these tools in such a way that new advances can be inserted easily, leading to an eventual medical decision support system.

  4. Reactor Operations informal monthly report December 1994

    International Nuclear Information System (INIS)

    1994-12-01

    Reactor operations at the MRR and HFBR reactors at Brookhaven National Laboratory are presented for December 1994. Reactor run-time and power levels, instrumentation, mechanical maintenance, occurrence reports, and safety information are included

  5. Derivation of residual radioactive material guidelines for 13 radionuclides present in Operable Unit IV at Brookhaven National Laboratory, Upton, New York

    International Nuclear Information System (INIS)

    Faillace, E.; Nimmagadda, M.; Yu, C.

    1994-12-01

    Residual radioactive material guidelines for 13 radionuclides (americium-241; cobalt-60; cesium-137; europium-152, -154, and -155; plutonium-238, -239, and -240; strontium-90; and uranium-234, -235, and -238) were derived for Operable Unit (OU) IV at Brookhaven National Laboratory. This site has been identified for remedial action under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980, as amended by the Superfund Amendments and Reauthorization Act of 1986. Single-nuclide guidelines were derived on the basis of the requirement that the 50-year committed effective dose equivalent to a hypothetical individual who lives or works in the immediate vicinity of OU IV should not exceed a dose constraint of 30 mrem/yr following remedial action for the current use and plausible future use scenarios or a dose limit of 100 mrem/yr for plausible but less likely future use scenarios. The US Department of Energy (DOE) residual radioactive material guideline computer code, RESRAD, was used in this evaluation; RESRAD implements the methodology described in the DOE manual for determining residual radioactive material guidelines. Four potential scenarios were considered; each assumed that, for a period of 1,000 years following remedial action, the site would be used without radiological restrictions. The four scenarios varied with regard to the type of site use, time spent at the site, and sources of food consumed

  6. The Brookhaven ATF low-emittance beam line

    International Nuclear Information System (INIS)

    Wang, X.J.

    1991-01-01

    One component of the experimental program at the Brookhaven Accelerator Test Facility (ATF) consists of a class of experiments which will study the acceleration of electrons through micron-size structures which are exposed in coincidence to a 100 GW CO 2 laser beam. These experiments require the development and control of an electron beam with geometric emittances on the order of 10 -10 m-rad and intensities on the order of 10 6 electrons. In this paper, we describe the strategies for producing such beams and the effects of high-order aberrations. Particle tracking results are presented for the final-focus system. 9 refs., 6 figs., 2 tabs

  7. The Relativistic Heavy Ion Collider at Brookhaven

    International Nuclear Information System (INIS)

    Hahn, H.

    1989-01-01

    The conceptual design of a collider capable of accelerating and colliding heavy ions and to be constructed in the existing 3.8 km tunnel at Brookhaven has been developed. The collider has been designed to provide collisions of gold ions at six intersection points with a luminosity of about 2 x 10 26 cm -2 sec -1 at an energy per nucleon of 100 GeV in each beam. Collisions with different ion species, including protons, will be possible. The salient design features and the reasons for major design choices of the proposed machine are discussed in this paper. 28 refs., 2 figs., 1 tab

  8. Cosmonauts and astronauts during medical operations training

    Science.gov (United States)

    1994-01-01

    Cosmonaut Alexandr F. Poleshchuk (right) inventories medical supplies with Ezra D. Kucharz, medical operations trainer for Krug Life Sciences, Incorporated. Poleshchuk, a Mir reserve crew member, and a number of other cosmonauts and astronauts participati

  9. Use of Neutron Irradiations in the Brookhaven Mutations Programme; Irradiation Neutronique dans le Cadre du Programme de Mutations Radioinduites de Brookhaven; Primenenie nejtronnogo izlucheniya v brukkhejvenskoj programme po ispol'zovaniyu mutatsij; La Irradiacion Neutronica en el Marco del Programa de Mutaciones Radioinducidas de Brookhaven

    Energy Technology Data Exchange (ETDEWEB)

    Miksche, J. P.; Shapiro, S. [Biology Department, Brookhaven National Laboratory, Upton, NY (United States)

    1964-03-15

    The Co-operative Radiation-Mutations Programme was established at Brookhaven National Laboratory approximately ten years ago to enable plant breeders and agriculturalists to make use of irradiation techniques in plant improvement programmes. The radiation facilities used in the programme are the thermal neutron column at the BGRR reactor, the 250-kVp X-ray machine in the Biology Department, the kilocurie gamma-sources in the Nuclear Engineering Department, a 12 c Co{sup 60} gamma-source in the greenhouse, and a 4000 c Co{sup 60} source located in a 13-acre field. The development of facilities, techniques, and theory represent Brookhaven's role in this cooperative project whereas the plant material and seed are provided by agricultural experts who are responsible for growing the irradiated material and screening for mutations. More than 150 scientists in 45 states and Puerto Rico are availing themselves of the programme's facilities. Projects have also initiated with Australia, Belgium, Chile, Costa Rica, Denmark, Ecuador, Formosa, Greece, Guatemala, India, Ireland, Italy, Japan, Kenya, Mexico, the Netherlands, Pakistan, Peru, the Philippines, Romania, South Africa.Thailand, Venezuela, West Germany and Yugoslavia. A review of the above cc-operative projects is presented with emphasis on the use of neutrons in mutation induction. (author) [French] Le programme commun de mutations radioinduites a ete mis en oeuvre, il y a une dizaine d'annees, au Laboratoire national de Brookhaven pour permettre aux phytogeneticiens et aux agronomes d'ameliorer les cultures a l 'aide des rayonnements. Les installations utilisees dans le cadre de ce programme sont les suivantes: colonne thermique du reacteur BGRR, appareil a rayons X de 250 kV-crete du Departement de biologie, sources de rayons gamma de 1000 c du Departement du genie nucleaire, source au {sup 60}Co de 12 c dans la serre et source au {sup 60}Co de 4000 c dans un champ experimental de 5 ha. Le role du Laboratoire deBrookhaven

  10. The neutrino horn 300 kiloampere pulsed power supply at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Sandberg, J.; Smith, G.A.; Carroll, A.S.

    1987-01-01

    A 300 Kiloampere pulsed power system used to energize the Brookhaven focusing neutrino horn is described. The constant current switching section, coaxial power feed and low level control system are presented. Calculations determining system performance are compared with measured values. Plans for future systems are discussed

  11. High Resolution Gamma Ray Analysis of Medical Isotopes

    Science.gov (United States)

    Chillery, Thomas

    2015-10-01

    Compton-suppressed high-purity Germanium detectors at the University of Massachusetts Lowell have been used to study medical radioisotopes produced at Brookhaven Linac Isotope Producer (BLIP), in particular isotopes such as Pt-191 used for cancer therapy in patients. The ability to precisely analyze the concentrations of such radio-isotopes is essential for both production facilities such as Brookhaven and consumer hospitals across the U.S. Without accurate knowledge of the quantities and strengths of these isotopes, it is possible for doctors to administer incorrect dosages to patients, thus leading to undesired results. Samples have been produced at Brookhaven and shipped to UML, and the advanced electronics and data acquisition capabilities at UML have been used to extract peak areas in the gamma decay spectra. Levels of Pt isotopes in diluted samples have been quantified, and reaction cross-sections deduced from the irradiation parameters. These provide both cross checks with published work, as well as a rigorous quantitative framework with high quality state-of-the-art detection apparatus in use in the experimental nuclear physics community.

  12. Brookhaven highlights, fiscal year 1985, October 1, 1984-September 30, 1985

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    Activities at Brookhaven National Laboratory are briefly discussed. These include work at the National Synchrotron Light Source, the High Flux Beam Reactor, and the Alternating Gradient Synchrotron. Areas of research include heavy ion reactions, neutrino oscillations, low-level waste, nuclear data, medicine, biology, chemistry, parallel computing, optics. Also provided are general and administrative news, a financial report. (LEW)

  13. Brookhaven highlights, fiscal year 1985, October 1, 1984-September 30, 1985

    International Nuclear Information System (INIS)

    1985-01-01

    Activities at Brookhaven National Laboratory are briefly discussed. These include work at the National Synchrotron Light Source, the High Flux Beam Reactor, and the Alternating Gradient Synchrotron. Areas of research include heavy ion reactions, neutrino oscillations, low-level waste, nuclear data, medicine, biology, chemistry, parallel computing, optics. Also provided are general and administrative news, a financial report

  14. Retrospective review of the clinical BNCT trial at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Diaz, A.Z.; Chanana, A.D.; Coderre, J.A.; Ma, R.

    2000-01-01

    The primary objective of the phase I/II dose escalation studies was to evaluate the safety of the boronophenylalanine-fructose (BPA-F) mediated boron neutron capture therapy (BNCT) in subjects with glioblastoma multiforme (GBM). A secondary objective was to retrospectively assess the palliation of GBM by BNCT. Fifty-three subjects with GBM were treated under multiple dose escalation protocols at the Brookhaven Medical Research Reactor (BMRR). Twenty-six subjects were treated using one field, 17 subjects were treated using 2 fields and 10 subjects were treated using 3 fields. BPA-F related toxicity was not observed. The maximum radiation dose to a volume of approximately 1 cc of the normal brain varied from 8.9 to 15.9 gray-equivalent (Gy-Eq). The volume-weighted average radiation dose to normal brain varied from 1.9 to 9.5 Gy-Eq. Six RTOG (Radiation Therapy Oncology Group) grade 3 or 4 toxicities were attributed to BNCT. Four of the 53 subjects are still alive with 3 of them free of recurrent disease with over two years follow-up. The median times to progression and median survival time from diagnosis were 28.4 weeks and 12.8 months respectively. (author)

  15. ATLAS Overview Week at Brookhaven

    CERN Multimedia

    Pilcher, J

    Over 200 ATLAS participants gathered at Brookhaven National Laboratory during the first week of June for our annual overview week. Some system communities arrived early and held meetings on Saturday and Sunday, and the detector interface group (DIG) and Technical Coordination also took advantage of the time to discuss issues of interest for all detector systems. Sunday was also marked by a workshop on the possibilities for heavy ion physics with ATLAS. Beginning on Monday, and for the rest of the week, sessions were held in common in the well equipped Berkner Hall auditorium complex. Laptop computers became the norm for presentations and a wireless network kept laptop owners well connected. Most lunches and dinners were held on the lawn outside Berkner Hall. The weather was very cooperative and it was an extremely pleasant setting. This picture shows most of the participants from a view on the roof of Berkner Hall. Technical Coordination and Integration issues started the reports on Monday and became a...

  16. Searching for the H-dibaryon at Brookhaven

    International Nuclear Information System (INIS)

    Bassalleck, B.; Athanas, M.; Berdoz, A.

    1996-01-01

    At the Brookhaven AGS several experiments are searching for the unique strangeness S = -2 H-dibaryon with the quark composition (uuddss). The E813/E836 collaboration, in particular, is using a high-intensity, separated 1.8 GeV/c K - beam and two different target configurations. In E836 the reaction K - + 3 He → K + + H + n is used to search for a relatively deeply-bound H. Complementary to E836 the reactions K - + p → Ξ + K + , followed by (Ξ - , d) atom → H + n are used to search near twice the Λ mass. The status of these two experiments is summarized, and other H-dibaryon searches are briefly reviewed. (author)

  17. Proceedings of Brookhaven National Laboratory's fusion/synfuel workshop

    International Nuclear Information System (INIS)

    Fillo, J.A.; Powell, J.R.

    1979-01-01

    The fusion synfuels workshop held at Brookhaven National Laboratory (BNL) on August 27-29, 1979 examined the current status of candidate synfuel processes and the R and D required to develop the capability for fusion synfuel production. Participants divided into five working groups, covering the following areas: (1) economics and applications; (2) high-temperature electrolysis; (3) thermochemical processes (including hybrid thermo-electrochemical); (4) blanket and materials; and (5) high-efficiency power cycles. Each working group presented a summary of their conclusions and recommendations to all participants during the third day of the Workshop. These summaries are given

  18. Science with multiply-charged ions at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Jones, K.W.; Johnson, B.M.; Meron, M.; Thieberger, P.

    1987-01-01

    The production of multiply-charged heavy ions at Brookhaven National Laboratory and their use in different types of experiments are discussed. The main facilities that are used are the Double MP Tandem Van de Graaff and the National Synchrotron Light Source. The capabilities of a versatile Atomic Physics Facility based on a combination of the two facilities and a possible new heavy-ion storage ring are summarized. It is emphasized that the production of heavy ions and the relevant science necessitates very flexible and diverse apparatus

  19. Brookhaven National Laboratory site report for calendar year 1988

    Energy Technology Data Exchange (ETDEWEB)

    Miltenberger, R.P.; Royce, B.A.; Naidu, J.R.

    1989-06-01

    Brookhaven National Laboratory (BNL) is managed by Associated Universities Inc. (AUI). AUI was formed in 1946 by a group of nine universities whose purpose was to create and manage a laboratory in the Northeast in order to advance scientific research in areas of interest to universities, industry, and government. On January 31, 1947, the contract for BNL was approved by the Manhattan District of the Army Corps of Engineers and BNL was established on the former Camp Upton army camp. 54 refs., 21 figs., 78 tabs.

  20. Brookhaven National Laboratory site report for calendar year 1988

    International Nuclear Information System (INIS)

    Miltenberger, R.P.; Royce, B.A.; Naidu, J.R.

    1989-06-01

    Brookhaven National Laboratory (BNL) is managed by Associated Universities Inc. (AUI). AUI was formed in 1946 by a group of nine universities whose purpose was to create and manage a laboratory in the Northeast in order to advance scientific research in areas of interest to universities, industry, and government. On January 31, 1947, the contract for BNL was approved by the Manhattan District of the Army Corps of Engineers and BNL was established on the former Camp Upton army camp. 54 refs., 21 figs., 78 tabs

  1. The Fiftieth Anniversary of Brookhaven National Laboratory: A Turbulent Time

    Science.gov (United States)

    Bond, Peter D.

    2018-03-01

    The fiftieth anniversary year of Brookhaven National Laboratory was momentous, but for reasons other than celebrating its scientific accomplishments. Legacy environmental contamination, community unrest, politics, and internal Department of Energy issues dominated the year. It was the early days of perhaps the most turbulent time in the lab's history. The consequences resulted in significant changes at the lab, but in addition they brought a change to contracts to manage the Department of Energy laboratories.

  2. Design of the beryllium window for Brookhaven Linac Isotope Producer

    International Nuclear Information System (INIS)

    Nayak, S.; Mapes, M.; Raparia, D.

    2015-01-01

    In the Brookhaven Linac Isotope Producer (BLIP) beam line, there were two Beryllium (Be) windows with an air gap to separate the high vacuum upstream side from low vacuum downstream side. There had been frequent window failures in the past which affected the machine productivity and increased the radiation dose received by workers due to unplanned maintenance. To improve the window life, design of Be window is reexamined. Detailed structural and thermal simulations are carried out on Be window for different design parameters and loading conditions to come up with better design to improve the window life. The new design removed the air gap and connect the both beam lines with a Be window in-between. The new design has multiple advantages such as 1) reduces the beam energy loss (because of one window with no air gap), 2) reduces air activation due to nuclear radiation and 3) increased the machine reliability as there is no direct pressure load during operation. For quick replacement of this window, an aluminum bellow coupled with load binder was designed. There hasn't been a single window failure since the new design was implemented in 2012.

  3. Recombinant Science: The Birth of the Relativistic Heavy Ion Collider (431st Brookhaven Lecture)

    International Nuclear Information System (INIS)

    Crease, Robert P.

    2007-01-01

    As part of the celebration of Brookhaven Lab's 60th anniversary, Robert P. Crease, the Chair of the Philosophy Department at Stony Brook University and BNL's historian, will present the second of two talks on the Lab's history. In 'Recombinant Science: The Birth of the Relativistic Heavy Ion Collider,' Dr. Crease will focus on the creation of the world's most powerful colliding accelerator for nuclear physics. Known as RHIC, the collider, as Dr. Crease will recount, was formally proposed in 1984, received initial construction funding from the U.S. Department of Energy in 1991, and started operating in 2000. In 2005, the discovery at RHIC of the world's most perfect liquid, a state of matter that last existed just moments after the Big Bang, was announced, and, since then, this perfect liquid of quarks and gluons has been the subject of intense study.

  4. Viscous liquid barrier demonstration at the Brookhaven National Laboratory Linac Isotope Producer

    International Nuclear Information System (INIS)

    Heiser, J.H.; Sullivan, T.; Ludewig, H.; Brower, J.; North-Abbott, M.; Manchester, K.; Zaluski, M.; Penny, G.

    2000-01-01

    Groundwater monitoring has detected tritium ( 3 H) and 22 Na contamination down gradient from the Brookhaven LINAC Isotope Producer (BLIP), located at Brookhaven National Laboratory (BNL). Site characterization studies indicate that the BLIP is the source of contamination. The highest measured values for 3 H were 52,400 pCi/L recorded less than 100 feet south (down gradient) of the BLIP facility. The BLIP produces radioisotopes that are crucial in nuclear medicine for both research and clinical use. The BLIP also supports research on diagnostic and therapeutic radiopharmaceuticals. During operation a proton beam impinges a target (typically salts encapsulated in stainless steel) to produce the required radioisotopes. The proton beam is completely absorbed prior to reaching the soils surrounding the target shaft. However, secondary neutrons are produced that reach the soil causing activation products to form. Among the longer-lived isotopes of concern are tritium and 22 Na. Both of these isotopes have the potential to negatively impact the groundwater below the BLIP. Several corrective actions have been implemented at the BLIP facility in response to tritium detection in the groundwater. The first actions were to improve surface water management (e.g. storm water down spouts) and the installation of a gunite cap around the BLIP facility. These measures are designed to minimize water flow through the activated soils in the vicinity of BLIP. In conjunction with these improvements, BNL is installing a close-proximity subsurface barrier in the activated soils beneath the BLIP facility. The barrier will prevent water migration through the activated soil zone as well as prevent activation product migration out of the zone. To minimize impacts on the operation of the BLIP requires in-situ barrier installation using low energy techniques that will not disturb the alignment of the BLIP or nearby accelerator beams. BNL chose an innovative barrier technology termed Viscous

  5. Elastic neutrino-electron scattering: a progress report on Exp734 at Brookhaven

    International Nuclear Information System (INIS)

    Abe, K.; Ahrens, L.A.; Amako, K.

    1983-01-01

    I will report preliminary results on elastic neutrino-electron scattering from data taken with the 200 ton segmented liquid scintillator - proportional drift-tube neutrino detector at Brookhaven. Features of the detector (such as the active target and long radiation length) permit a uniquely clean signal. Prospects of results from the completed analysis and further data taking are discussed

  6. From nuclei to hypernuclei: A retrospective view of medium energy physics at Brookhaven

    International Nuclear Information System (INIS)

    Chrien, R.E.

    2000-01-01

    A new frontier in physics originated with programs at two Brookhaven National Laboratory facilities--the Cosmotron and the Alternating Gradient Synchrotron. The development of this frontier over a half century is described, as it turned from conventional nuclear physics to the hypernuclei and the study of strange matter

  7. Medical Logistics Lessons Observed During Operations Enduring Freedom and Iraqi Freedom.

    Science.gov (United States)

    Dole, Mark J; Kissane, Jonathan M

    2016-01-01

    Medical Logistics (MEDLOG) is a function of the Army's integrated System for Health that provides the medical products and specialized logistics services required to deliver health protection and care under all operational conditions. In unified land operations, MEDLOG is an inherent function of Health Service Support (HSS), which also includes casualty care and medical evacuation. This paper focuses on a few key lessons observed during Operations Enduring Freedom and Iraqi Freedom with direct implications for the support of HSS in future operations as envisioned in the Army Operating Concept and the Joint Concept for Health Services. It also examines a few key enablers that helped mitigate these challenges that are not yet fully acknowledged in Army Medical Department doctrine, policy, and planning.

  8. Operational status of the Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Chou, T.S.; Los Alamos National Lab., NM; Princeton Univ., NJ

    1989-01-01

    Design and operation of a 50 MeV Electron Linear Accelerator utilizing a low emittance (γ var epsilon = 5 to 10 mm-mrad) radio frequency gun operating at an output energy of 5 MeV and a charge of 1 nC is described. Design calculations and early radio frequency measurements and operational experience with the electron gun utilizing a dummy copper cathode in place of the proposed photocathode emitter are given. 6 refs., 9 figs., 1 tab

  9. Medical support for law enforcement-extended operations incidents.

    Science.gov (United States)

    Levy, Matthew J; Tang, Nelson

    2014-01-01

    As the complexity and frequency of law enforcement-extended operations incidents continue to increase, so do the opportunities for adverse health and well-being impacts on the responding officers. These types of clinical encounters have not been well characterized nor have the medical response strategies which have been developed to effectively manage these encounters been well described. The purpose of this article is to provide a descriptive epidemiology of the clinical encounters reported during extended law enforcement operations, as well as to describe a best practices approach for their effective management. This study retrospectively examined the clinical encounters of the Maryland State Police (MSP) Tactical Medical Unit (TMU) during law enforcement extended operations incidents lasting 8 or more hours. In addition, a qualitative analysis was performed on clinical data collected by federal law enforcement agencies during their extended operations. Forty-four percent of missions (455/1,047) supported by the MSP TMU lasted 8 or more hours. Twenty-six percent of these missions (117/455) resulted in at least one patient encounter. Nineteen percent of patient chief complaints (45/238) were related to heat illness/ dehydration. Fifteen percent of encounters (36/238) were for musculoskeletal injury/pain. Eight percent of patients (19/238) had nonspecific sick call (minor illness) complaints. The next most common occurring complaints were cold-related injuries, headache, sinus congestion, and wound/laceration, each of which accounted for 7 percent of patients (16/238), respectively. Analysis of federal law enforcement agencies' response to such events yielded similar clinical encounters. A wide range of health problems are reported by extended law enforcement operations personnel. Timely and effective treatment of these problems can help ensure that the broader operations mission is not compromised. An appropriate operational strategy for managing health complaints

  10. Brookhaven Lab physicist William Willis wins the 2003 W.K.H. Panofsky prize

    CERN Multimedia

    2003-01-01

    William Willis, a senior physicist Brookhaven National Laboratory, has won the American Physical Society's 2003 W.K.H. Panofsky Prize in Experimental Particle Physics. He received the prize, which consists of $5,000 and a certificate citing his contributions to physics, at the APS meeting in Philadelphia on April 6 (1 page).

  11. Early history of the Cosmotron and AGS at Brookhaven

    International Nuclear Information System (INIS)

    Courant, E.D.

    1989-01-01

    Early work is described on the design and construction of the two Brookhaven particle accelerators of the 1950s, the Cosmotron and the AGS (alternating-gradient synchrotron). The Cosmotron, finished by the Spring of 1952, was the smaller machine reaching 3GeV and was the first to pass the billion electron volt mark. Suggested alterations to magnet orientations meant that the alternating gradients produced would stabilize the design. This ''strong-focusing'' idea was central to the second AGS machine, which also overcame the problems of resonances and transition energy, with the inclusion of an electron analog accelerator. (UK)

  12. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1. Volume 5: Analysis of core damage frequency from seismic events during mid-loop operations

    International Nuclear Information System (INIS)

    Budnitz, R.J.; Davis, P.R.; Ravindra, M.K.; Tong, W.H.

    1994-08-01

    In 1989 the US Nuclear Regulatory Commission (NRC) initiated an extensive program to examine carefully the potential risks during low-power and shutdown operations. The program included two parallel projects, one at Brookhaven National Laboratory studying a pressurized water reactor (Surry Unit 1) and the other at Sandia National Laboratories studying a boiling water reactor (Grand Gulf). Both the Brookhaven and Sandia projects have examined only accidents initiated by internal plant faults--so-called ''internal initiators.'' This project, which has explored the likelihood of seismic-initiated core damage accidents during refueling shutdown conditions, is complementary to the internal-initiator analyses at Brookhaven and Sandia. This report covers the seismic analysis at Surry Unit 1. All of the many systems modeling assumptions, component non-seismic failure rates, and human error rates that were used in the internal-initiator study at Surry have been adopted here, so that the results of the two studies can be as comparable as possible. Both the Brookhaven study and this study examine only two shutdown plant operating states (POSs) during refueling outages at Surry, called POS 6 and POS 10, which represent mid-loop operation before and after refueling, respectively. This analysis has been limited to work analogous to a level-1 seismic PRA, in which estimates have been developed for the core-damage frequency from seismic events during POSs 6 and 10. The results of the analysis are that the core-damage frequency of earthquake-initiated accidents during refueling outages in POS 6 and POS 10 is found to be low in absolute terms, less than 10 -6 /year

  13. Operation of the Brookhaven 200 MeV Linac

    International Nuclear Information System (INIS)

    Fewell, N.M.; LoDestro, V.

    1979-01-01

    During the past three years the 200 MeV linear accelerator has continued to operate at a high level of performance and reliability. The linac output beam current has been limited to 60 mA in order to obtain the maximum rf power tube life without compromising the output performance of the AGS. Despite a reduction in pulse repetition rate, total beam current to the BLIP facility has increased to an average of 300 mA hours/year

  14. Environmental Survey preliminary report, Brookhaven National Laboratory, Upton, New York

    Energy Technology Data Exchange (ETDEWEB)

    1988-06-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Brookhaven National Laboratory (BNL) conducted April 6 through 17, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with BNL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at BNL, and interviews with site personnel. The Survey team developed a Sampling and Analysis Plan to assist in further assessing specific environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by Oak Ridge National Laboratory. When completed, the results will be incorporated into the BNL Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the BNL Survey. 80 refs., 24 figs., 48 tabs.

  15. Environmental Survey preliminary report, Brookhaven National Laboratory, Upton, New York

    International Nuclear Information System (INIS)

    1988-06-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Brookhaven National Laboratory (BNL) conducted April 6 through 17, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with BNL. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at BNL, and interviews with site personnel. The Survey team developed a Sampling and Analysis Plan to assist in further assessing specific environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by Oak Ridge National Laboratory. When completed, the results will be incorporated into the BNL Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the BNL Survey. 80 refs., 24 figs., 48 tabs

  16. Brookhaven four-stage accel-decel production of low-energy highly stripped heavy ions

    International Nuclear Information System (INIS)

    Barrette, J.; Thieberger, P.

    1981-01-01

    The dual MP tandem facility at Brookhaven has been used in a four-stage accel-decel mode to produce highly stripped S ion beams (Q = 10-16 + ). Fully stripped S ions were obtained at energies down to 8 MeV. The low energy limit is presently due to the inclined field configuration of the last acceleration tube

  17. The Grumman/Brookhaven high-brightness, high-duty factor RF gun

    International Nuclear Information System (INIS)

    Lehrman, I.S.; Birnbaum, I.A.; Cole, M.; Fixler, S.Z.; Heuer, R.L.; Siddiqi, S.; Sheedy, E.; Waren, G.D.

    1992-01-01

    Under a joint collaboration between Brookhaven National Laboratory and the Grumman Corporation, a high-duty (>1%) photocathode RF gun is under construction for use at the ATF facility at BNL. The gun will be capable of producing short ( 300 A (after compression) and a total bunch charge in excess of 3 nC. The gun consists of 3-1/2 cells constructed from GlidCop, an alumina dispersion strengthened copper alloy. Two individually phased waveguides are used to power the first two and final two cells. (Author) 10 refs., 8 figs., 2 tabs

  18. BROOKHAVEN: Major detectors for RHIC under construction

    International Nuclear Information System (INIS)

    Ludlam, Thomas W.

    1994-01-01

    On March 9-10, a cost and schedule review at Brookhaven verified construction readiness for the PHENIX detector (May 1993, page 10). PHENIX thus joins STAR (Solenoidal Tracking at RHIC - November 1991, page 17), whose construction plan was ratified in January 1993, as a major detector to take data when the RHIC heavy ion collider is completed in mid-1999. The goal of both detectors is to search for the transition from ordinary nuclear matter to a new state of matter consisting of (momentarily) unconfined quarks and gluons. This transition to a ''quark-gluon plasma'' (QGP) is predicted to occur under extreme conditions of temperature and energy density, as is likely to be the case in the collision of heavy ions of sufficient energy. RHIC is expected to produce the highest energy densities ever observed on the nuclear scale

  19. The new Brookhaven $(g-2)_{\\mu}$ experiment

    CERN Document Server

    Hertzog, D W; Bunce, G M; Carey, R M; Cushman, P B; Danby, G T; Debevec, P T; Deng, H; Deninger, W J; Dhawan, S K; Druzhinin, V P; Duong, L; Earle, W; Efstathiadis, E F; Farley, Francis J M; Fedotovich, G V; Giron, S; Gray, F; Grosse-Perdekamp, M; Grossmann, A; Haeberlen, U; Hare, M; Hazen, E S; Hughes, V W; Iwassaki, M; Jungmann, Klaus; Kawall, D; Kawamura, M; Khazin, B I; Kindem, J; Krienen, F; Kronkvist, I J; Larsen, R; Lee, Y Y; Liu, W; Logashenko, I B; McNabb, R; Meng, W; Mi, J L; Miller, J P; Morse, W M; Onderwater, Gerco; Orlov, Yu F; Pai, C; Polly, C; Pretz, J; Prigl, R; zu Putlitz, Gisbert; Redin, S I; Rind, O; Roberts, B L; Ryskulov, N M; Sanders, R; Sedykh, S N; Semertzidis, Y K; Serednyakov, S I; Shatunov, Yu M; Solodov, E P; Sossong, M; Steinmetz, A; Sulak, Lawrence R; Timmermans, C; Trofimov, A V; Urner, D; Warburton, D; Winn, D; Xu, Q; Yamamoto, A; Zimmerman, D

    1999-01-01

    A new assault on the muon's anomalous magnetic moment has begun with a vigorous effort by the Brookhaven E821 collaboration. The present group has refined the design used in a series of successful CERN experiments in order to lower the systematic uncertainties. Consequently it will be possible to take advantage of the greatly increased muon flux provided for at the AGS. Several novel techniques are employed, of which the most significant is a direct muon injection scheme. Upon reaching the goal of the experiment, comparison with theory will offer sensitive teats of both the electroweak corrections and physics beyond the standard model. At the time of this symposium, data from the first engineering run has been analyzed, yielding a result whose precision and value are comparable to those generated by the last CERN effort. (23 refs).

  20. Towards automated assistance for operating home medical devices.

    Science.gov (United States)

    Gao, Zan; Detyniecki, Marcin; Chen, Ming-Yu; Wu, Wen; Hauptmann, Alexander G; Wactlar, Howard D

    2010-01-01

    To detect errors when subjects operate a home medical device, we observe them with multiple cameras. We then perform action recognition with a robust approach to recognize action information based on explicitly encoding motion information. This algorithm detects interest points and encodes not only their local appearance but also explicitly models local motion. Our goal is to recognize individual human actions in the operations of a home medical device to see if the patient has correctly performed the required actions in the prescribed sequence. Using a specific infusion pump as a test case, requiring 22 operation steps from 6 action classes, our best classifier selects high likelihood action estimates from 4 available cameras, to obtain an average class recognition rate of 69%.

  1. Brookhaven National Laboratory source water assessment for drinking water supply wells

    International Nuclear Information System (INIS)

    Bennett, D.B.; Paquette, D.E.; Klaus, K.; Dorsch, W.R.

    2000-01-01

    The BNL water supply system meets all water quality standards and has sufficient pumping and storage capacity to meet current and anticipated future operational demands. Because BNL's water supply is drawn from the shallow Upper Glacial aquifer, BNL's source water is susceptible to contamination. The quality of the water supply is being protected through (1) a comprehensive program of engineered and operational controls of existing aquifer contamination and potential sources of new contamination, (2) groundwater monitoring, and (3) potable water treatment. The BNL Source Water Assessment found that the source water for BNL's Western Well Field (comprised of Supply Wells 4, 6, and 7) has relatively few threats of contamination and identified potential sources are already being carefully managed. The source water for BNL's Eastern Well Field (comprised of Supply Wells 10, 11, and 12) has a moderate number of threats to water quality, primarily from several existing volatile organic compound and tritium plumes. The g-2 Tritium Plume and portions of the Operable Unit III VOC plume fall within the delineated source water area for the Eastern Well Field. In addition, portions of the much slower migrating strontium-90 plumes associated with the Brookhaven Graphite Research Reactor, Waste Concentration Facility and Building 650 lie within the Eastern source water area. However, the rate of travel in the aquifer for strontium-90 is about one-twentieth of that for tritium and volatile organic compounds. The Laboratory has been carefully monitoring plume migration, and has made adjustments to water supply operations. Although a number of BNL's water supply wells were impacted by VOC contamination in the late 1980s, recent routine analysis of water samples from BNL's supply wells indicate that no drinking water standards have been reached or exceeded. The high quality of the water supply strongly indicates that the operational and engineered controls implemented over the past

  2. Electronic Procedures for Medical Operations, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Electronic procedures are currently being used to document the steps in performing medical operations for the Space Shuttle and/or the International Space Station...

  3. Is Overeating Behavior Similar to Drug Addiction? (427th Brookhaven Lecture)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Gene-Jack

    2007-09-27

    The increasing number of obese individuals in the U.S. and other countries world-wide adds urgency to the need to understand the mechanisms underlying pathological overeating. Research by the speaker and others at Brookhaven National Laboratory and elsewhere is compiling evidence that the brain circuits disrupted in obesity are similar to those involved in drug addiction. Using positron emission tomography (PET), the speaker and his colleagues have implicated brain dopamine in the normal and the pathological intake of food by humans. During the 427th Brookhaven Lecture, speaker will review the findings and implications of PET studies of obese subjects and then compare them to PET research involving drug-addicted individuals. For example, in pathologically obese subjects, it was found that reductions in striatal dopamine D2 receptors are similar to those observed in drug-addicted subjects. The speaker and his colleagues have postulated that decreased levels of dopamine receptors predisposed subjects to search for strongly rewarding reinforcers, be it drugs for the drug-addicted or food for the obese, as a means to compensate for decreased sensitivity of their dopamine-regulated reward circuits. As the speaker will summarize, multiple but similar brain circuits involved in reward, motivation, learning and inhibitory control are disrupted both in drug addiction and obesity, resulting in the need for a multimodal approach to the treatment of obesity.

  4. The Next Generation of Heavy Ion Sources (447th Brookhaven Lecture)

    International Nuclear Information System (INIS)

    Okamura, Masahiro

    2009-01-01

    Imagine if, by staying in your lane when driving on the expressway, you could help fight cancer or provide a new, clean energy source. You would clench the steering wheel with both hands and stay in your lane, right? Unlike driving on the expressway where you intentionally avoid hitting other cars, scientists sometimes work to steer particle beams into head-on collisions with other oncoming particle beams. However, the particles must be kept 'in their lanes' for cleaner, more frequent collisions. Some scientists propose starting the whole process by using lasers to heat a fixed target as a way to get particles with higher charge, which are more steerable. These scientists believe the new methods could be used to develop particle beams for killing cancer cells or creating usable energy from fusion. Join Masahiro Okamura of Brookhaven's Collider-Accelerator Department for the 447th Brookhaven Lecture, titled 'The Next Generation of Heavy Ion Sources.' Okamura will explain how lasers can be used to create plasma, neutral mixtures of positive ions and negative electrons, from different materials, and how using this plasma leads to beams with higher charge states and currents. He will also discuss how this efficient, simpler method of producing particle beams might be used for cancer therapy, to develop new energy sources, or in synchrotrons.

  5. Is Overeating Behavior Similar to Drug Addiction? (427th Brookhaven Lecture)

    International Nuclear Information System (INIS)

    Wang, Gene-Jack

    2007-01-01

    The increasing number of obese individuals in the U.S. and other countries world-wide adds urgency to the need to understand the mechanisms underlying pathological overeating. Research by the speaker and others at Brookhaven National Laboratory and elsewhere is compiling evidence that the brain circuits disrupted in obesity are similar to those involved in drug addiction. Using positron emission tomography (PET), the speaker and his colleagues have implicated brain dopamine in the normal and the pathological intake of food by humans. During the 427th Brookhaven Lecture, speaker will review the findings and implications of PET studies of obese subjects and then compare them to PET research involving drug-addicted individuals. For example, in pathologically obese subjects, it was found that reductions in striatal dopamine D2 receptors are similar to those observed in drug-addicted subjects. The speaker and his colleagues have postulated that decreased levels of dopamine receptors predisposed subjects to search for strongly rewarding reinforcers, be it drugs for the drug-addicted or food for the obese, as a means to compensate for decreased sensitivity of their dopamine-regulated reward circuits. As the speaker will summarize, multiple but similar brain circuits involved in reward, motivation, learning and inhibitory control are disrupted both in drug addiction and obesity, resulting in the need for a multimodal approach to the treatment of obesity.

  6. 1995 Annual epidemiologic surveillance report for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The US Department of Energy`s (DOE) conduct of epidemiologic surveillance provides an early warning system for health problems among workers. This program monitors illnesses and health conditions that result in an absence of five or more consecutive workdays, occupational injuries and illnesses, and disabilities and deaths among current workers. This report summarizes epidemiologic surveillance data collected from Brookhaven National Laboratory (BNL) from January 1, 1995 through December 31, 1995. The data were collected by a coordinator at BNL and submitted to the Epidemiologic Surveillance Data Center, located at Oak Ridge Institute for Science and Education, where quality control procedures and data analyses were carried out.

  7. A microwiggler Free-Electron Laser at the Brookhaven Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Fernow, R.; Gallardo, J.; Kirk, H.; Pellegrini, C.; van Steenbergen, A.; Bhowmik, A.; Rockwell International Corp., Canoga Park, CA

    1989-01-01

    We report the design and status of an FEL experiment at the Brookhaven National Laboratory Accelerator Test Facility. A 50 MeV high brightness electron beam will be utilized for an oscillator experiment in the visible wavelength region. The microwiggler to be used is a superferric planar undulator with a 0.88 cm period, 60 cm length and K = 0.35. The optical cavity is a 368 cm long stable resonator with broadband dielectric coated mirrors. 8 refs., 2 figs., 4 tabs

  8. Higher-order-mode absorbers for energy recovery linac cryomodules at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Hahn, H.; Ben-Zvi, I.; Calaga, R.; Hammons, L.; Johnson, E.C.; Kewisch, J.; Litvinenko, V.N.; Xu, W.

    2010-01-01

    Several future accelerator projects at Brookhaven for the Relativistic Heavy Ion Collider (RHIC) are based on energy recovery linacs (ERLs) with high-charge high-current electron beams. Their stable operation mandates effective higher-order-mode (HOM) damping. The development of HOM dampers for these projects is pursued actively at this laboratory. Strong HOM damping was experimentally demonstrated both at room and at superconducting (SC) temperatures in a prototype research and development (R and D) five-cell niobium superconducting rf (SRF) cavity with ferrite dampers. Two room-temperature mock-up five-cell copper cavities were used to study various damper configurations with emphasis on capacitive antenna dampers. An innovative type of ferrite damper over a ceramic break for an R and D SRF electron gun also was developed. For future SRF linacs longer cryomodules comprised of multiple superconducting cavities with reasonably short intercavity transitions are planned. In such a configuration, the dampers, located closer to the cavities, will be at cryogenic temperatures; this will impose additional constraints and complications. This paper presents the results of simulations and measurements of several damper configurations.

  9. Higher-order-mode absorbers for energy recovery linac cryomodules at Brookhaven National Laboratory

    Science.gov (United States)

    Hahn, H.; Ben-Zvi, I.; Calaga, R.; Hammons, L.; Johnson, E. C.; Kewisch, J.; Litvinenko, V. N.; Xu, Wencan

    2010-12-01

    Several future accelerator projects at Brookhaven for the Relativistic Heavy Ion Collider (RHIC) are based on energy recovery linacs (ERLs) with high-charge high-current electron beams. Their stable operation mandates effective higher-order-mode (HOM) damping. The development of HOM dampers for these projects is pursued actively at this laboratory. Strong HOM damping was experimentally demonstrated both at room and at superconducting (SC) temperatures in a prototype research and development (R&D) five-cell niobium superconducting rf (SRF) cavity with ferrite dampers. Two room-temperature mock-up five-cell copper cavities were used to study various damper configurations with emphasis on capacitive antenna dampers. An innovative type of ferrite damper over a ceramic break for an R&D SRF electron gun also was developed. For future SRF linacs longer cryomodules comprised of multiple superconducting cavities with reasonably short intercavity transitions are planned. In such a configuration, the dampers, located closer to the cavities, will be at cryogenic temperatures; this will impose additional constraints and complications. This paper presents the results of simulations and measurements of several damper configurations.

  10. Higher-order-mode absorbers for energy recovery linac cryomodules at Brookhaven National Laboratory

    Directory of Open Access Journals (Sweden)

    H. Hahn

    2010-12-01

    Full Text Available Several future accelerator projects at Brookhaven for the Relativistic Heavy Ion Collider (RHIC are based on energy recovery linacs (ERLs with high-charge high-current electron beams. Their stable operation mandates effective higher-order-mode (HOM damping. The development of HOM dampers for these projects is pursued actively at this laboratory. Strong HOM damping was experimentally demonstrated both at room and at superconducting (SC temperatures in a prototype research and development (R&D five-cell niobium superconducting rf (SRF cavity with ferrite dampers. Two room-temperature mock-up five-cell copper cavities were used to study various damper configurations with emphasis on capacitive antenna dampers. An innovative type of ferrite damper over a ceramic break for an R&D SRF electron gun also was developed. For future SRF linacs longer cryomodules comprised of multiple superconducting cavities with reasonably short intercavity transitions are planned. In such a configuration, the dampers, located closer to the cavities, will be at cryogenic temperatures; this will impose additional constraints and complications. This paper presents the results of simulations and measurements of several damper configurations.

  11. Nuclear medicine at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Atkins, H.L.

    1976-01-01

    The Nuclear Medicine Program at the Brookhaven National Laboratory seeks to develop new materials and methods for the investigation of human physiology and disease processes. Some aspects of this research are related to basic research of how radiopharmaceuticals work. Other aspects are directed toward direct applications as diagnostic agents. It is likely that cyclotron-produced positron emitting nuclides will assume greater importance in the next few years. This can be attributed to the ability to label biologically important molecules with high specific activity without affecting biological activity, using 11 C, 13 N, and 15 O. Large quantities of these short-lived nuclides can be administered without excessive radiation dose and newer instrumentation will permit reconstructive axial tomography, providing truly quantitative display of distribution of radioactivity. The 122 Xe- 122 I generator has the potential for looking at rapid dynamic processes. Another generator, the 68 Ge- 68 Ga generator produces a positron emitter for the use of those far removed from cyclotrons. The possibilities for 68 Ga radiopharmaceuticals are as numerous as those for /sup 99m/Tc diagnostic agents

  12. Proto-2, an ALICE detector prototype, part of the STAR experiment at the Brookhaven National Laboratory

    CERN Multimedia

    2002-01-01

    Proto-2, an LAICE detector prototype, overcame its prototype status to become a real part of the SDTAR, epxeriment at the US Brookhaven National Laboratory. After more than two years across the ocean, it has just arrived back at CERN.

  13. Mechanical support and transport system used for the neutrino horn system at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Walker, J.C.; Carroll, A.S.; Leonhardt, W.

    1987-01-01

    The study of neutrinos at the Alternating Gradient Synchrotron (AGS), Brookhaven National Laboratory (BNL), requires hardware for their initiation and control. The basics consist of a target, two horns and three collimators. This paper describes the installation, support and positioning of these components within a settling concrete blockhouse

  14. Operational status of the Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Fernow, R.C.; Fischer, A.S.; Gallardo, J.; Jialin, Xie; Kirk, H.G.; Malone, R.G.; Parsa, Z.; Palmer, R.B.; Rao, T.; Rogers, J.; Sheehan, J.; Tsang, T.Y.F.; Ulc, S.; van Steenbergen, A.; Woodle, M.; Zhang, R.S.; Bigio, I.; Kurnit, N.; Shimada, T.; McDonald, K.T.; Russel, D.P.; Jiang, Z.Y.; Pellegrini, C.; Wang, X.J.

    1990-01-01

    Initial design parameters and early operational results of a 50 MeV high brightness electron linear accelerator are described. The system utilizes a radio frequency electron gun operating at a frequency of 2.856 GHz and a nominal output energy of 4.5 MeV followed by two, 2π/3 mode, disc loaded, traveling wave accelerating sections. The gun cathode is photo excited with short (6 psec) laser pulses giving design peak currents of a few hundred amperes. The system will be utilized to carry out infra-red FEL studies and investigation of new high gradient accelerating structures

  15. POLARIZED BEAMS: 2 - Partial Siberian Snake rescues polarized protons at Brookhaven

    International Nuclear Information System (INIS)

    Huang, Haixin

    1994-01-01

    To boost the level of beam polarization (spin orientation), a partial 'Siberian Snake' was recently used to overcome imperfection depolarizing resonances in the Brookhaven Alternating Gradient Synchrotron (AGS). This 9-degree spin rotator recently permitted acceleration with no noticeable polarization loss. The intrinsic AGS depolarizing resonances (which degrade the polarization content) had been eliminated by betatron tune jumps, but the imperfection resonances were compensated by means of harmonic orbit corrections. However, at high energies these orbit corrections are difficult and tedious and a Siberian Snake became an attractive alternative

  16. X-ray holographic microscopy experiments at the Brookhaven synchrotron light source

    International Nuclear Information System (INIS)

    Howells, M.R.; Iarocci, M.; Kenney, J.; Kirz, J.; Rarback, H.

    1983-01-01

    Soft x-ray holographic microscopy is discussed from an experimental point of view. Three series of measurements have been carried out using the Brookhaven 750 MeV storage ring as an x-ray source. Young slits fringes, Gabor (in line) holograms and various data pertaining to the soft x-ray performance of photographic plates are reported. The measurements are discussed in terms of the technique for recording them and the experimental limitations in effect. Some discussion is also given of the issues involved in reconstruction using visible light

  17. SPACE MEDICINE and Medical Operations Overview

    Science.gov (United States)

    Dervay, Joe

    2009-01-01

    This presentation is an overview of the function of the work of the Space Medicine & Health Care Systems Office. The objective of the medical operations is to ensure the health, safety and well being of the astronaut corps and ground support team during all phases of space flight. There are many issues that impact the health of the astronauts. Some of them are physiological, and others relate to behavior, psychological issues and issues of the environment of space itself. Reviews of the medical events that have affected both Russian, and Americans while in space are included. Some views of shuttle liftoff, and ascent, the medical training aboard NASA's KC-135 and training in weightlessness, the Shuttle Orbiter Medical system (SOMS), and some of the medical equipment are included. Also included are a graphs showing Fluid loading countermeasures, and vertical pursuit tracking with head and eye. The final views are representations of the future crew exploration vehicle (CEV) approaching the International Space Station, and the moon, and a series of perspective representations of the earth in comparison to the other planets and the Sun, the Sun in relation to other stars, and a view of where in the galaxy the Sun is.

  18. Organization, Management and Function of International Space Station (ISS) Multilateral Medical Operations

    Science.gov (United States)

    Duncan, James M.; Bogomolov, V. V.; Castrucci, F.; Koike, Y.; Comtois, J. M.; Sargsyan, A. E.

    2007-01-01

    Long duration crews have inhabited the ISS since November of 2000. The favorable medical outcomes of its missions can be largely attributed to sustained collective efforts of all ISS Partners medical organizations. In-flight medical monitoring and support, although crucial, is just a component of the ISS system of Joint Medical Operations. The goal of this work is to review the principles, design, and function of the multilateral medical support of the ISS Program. The governing documents, which describe the relationships among all ISS partner medical organizations, were evaluated, followed by analysis of the roles, responsibilities, and decision-making processes of the ISS medical boards, panels, and working groups. The degree of integration of the medical support system was evaluated by reviewing the multiple levels of the status reviews and mission assurance activities carried out throughout the last six years. The Integrated Medical Group, consisting of physicians and other essential personnel in the mission control centers represents the front-line medical support of the ISS. Data from their day-to-day activities are presented weekly at the Space Medicine Operations Team (SMOT), where known or potential concerns are addressed by an international group of physicians. A broader status review is conducted monthly to project the state of crew health and medical support for the following month, and to determine measures to return to nominal state. Finally, a comprehensive readiness review is conducted during preparations for each ISS mission. The Multilateral Medical Policy Board (MMPB) issues medical policy decisions and oversees all health and medical matters. The Multilateral Space Medicine Board (MSMB) certifies crewmembers and visitors for training and space flight to the Station, and physicians to practice space medicine for the ISS. The Multilateral Medical Operations Panel (MMOP) develops medical requirements, defines and supervises implementation of

  19. The application of digital medical 3D printing technology on tumor operation

    Science.gov (United States)

    Chen, Jimin; Jiang, Yijian; Li, Yangsheng

    2016-04-01

    Digital medical 3D printing technology is a new hi-tech which combines traditional medical and digital design, computer science, bio technology and 3D print technology. At the present time there are four levels application: The printed 3D model is the first and simple application. The surgery makes use of the model to plan the processing before operation. The second is customized operation tools such as implant guide. It helps doctor to operate with special tools rather than the normal medical tools. The third level application of 3D printing in medical area is to print artificial bones or teeth to implant into human body. The big challenge is the fourth level which is to print organs with 3D printing technology. In this paper we introduced an application of 3D printing technology in tumor operation. We use 3D printing to print guide for invasion operation. Puncture needles were guided by printed guide in face tumors operation. It is concluded that this new type guide is dominantly advantageous.

  20. Habitat Demonstration Unit Medical Operations Workstation Upgrades

    Science.gov (United States)

    Trageser, Katherine H.

    2011-01-01

    This paper provides an overview of the design and fabrication associated with upgrades for the Medical Operations Workstation in the Habitat Demonstration Unit. The work spanned a ten week period. The upgrades will be used during the 2011 Desert Research and Technology Studies (Desert RATS) field campaign. Upgrades include a deployable privacy curtain system, a deployable tray table, an easily accessible biological waste container, reorganization and labeling of the medical supplies, and installation of a retractable camera. All of the items were completed within the ten week period.

  1. Toward Catalyst Design from Theoretical Calculations (464th Brookhaven Lecture)

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ping (BNL Chemistry Dept)

    2010-12-15

    Catalysts have been used to speed up chemical reactions as long as yeast has been used to make bread rise. Today, catalysts are used everywhere from home kitchens to industrial chemical factories. In the near future, new catalysts being developed at Brookhaven Lab may be used to speed us along our roads and highways as they play a major role in solving the world’s energy challenges. During the lecture, Liu will discuss how theorists and experimentalists at BNL are working together to formulate and test new catalysts that could be used in real-life applications, such as hydrogen-fuel cells that may one day power our cars and trucks.

  2. Operation of the Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program

  3. Biometrics in support of special forces medical operations.

    Science.gov (United States)

    Kershner, Michael R

    2012-01-01

    Recommendations on ways in which the ODA can leverage biometrics in medical operations to improve their security, improve relations with indigenous personnel, and contribute to the larger theater biometrics program. 2012.

  4. 2003 Brookhaven National Laboratory Annual Illness and Injury Surveillance Report, Revised September 2007

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Security, Office of Illness and Injury Prevention Programs

    2007-10-02

    Annual Illness and Injury Surveillance Program report for 2003 for Brookhaven National Lab. The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The IISP monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  5. Operation of the Brookhaven national laboratory accelerator test facility

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Botke, I.; Chou, T.S.; Fernow, R.; Fischer, J.; Fisher, A.; Gallardo, J.; Ingold, G.; Malone, R.; Palmer, R.; Parsa, Z.; Pogorelsky, I.; Rogers, J.; Sheehan, J.; Srinivasan-Rao, T.; Tsang, T.; Ulc, S.; Van Steenbergen, A.; Wang, X.J.; Woodle, M.; Yu, L.H.

    1992-01-01

    Early operation of the 50 MeV high brightness electron linac of the Accelerator Test Facility is described along with experimental data. This facility is designed to study new linear acceleration techniques and new radiation sources based on linacs in combination with free electron lasers. The accelerator utilizes a photo-excited, metal cathode, radio frequency electron gun followed by two travelling wave accelerating sections and an Experimental Hall for the study program. (Author) 5 refs., 4 figs., tab

  6. Assessment of Energy Efficiency Project Financing Alternatives for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, W. D.; Hail, John C.; Sullivan, Gregory P.

    2000-02-14

    This document provides findings and recommendations that resulted from an assessment of the Brookhaven National Laboratory by a team from Pacific Northwest National Laboratory to assess the site's potential for various alternative financing options as a means to implement energy-efficiency improvements. The assessment looked for life-cycle cost-effective energy-efficiency improvement opportunities, and through a series of staff interviews, evaluated the various methods by which these opportunities may be financed, while considering availability of funds, staff, and available financing options. This report summarizes the findings of the visit and the resulting recommendations.

  7. Medical application of in-vivo neutron activation analysis at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Cohn, S.H.; Ellis, K.J.; Vartsky, D.; Zanzi, I.; Aloia, J.F.

    1979-01-01

    Total-body calcium measurements utilizing TBNAA have been used in studies of osteoporosis to establish absolute and relative deficits of calcium in patients with this disease in comparison to a normal contrast population. Changes in total-body calcium (skeletal mass) have also been useful for quantitating the efficacy of various therapies in osteoporosis. Serial measurements over periods of years provide long-term balance data by direct measurement with a higher precision (+-2%) than is possible by the use of any other technique. In the renal osteodystrophy observed in patients with renal failure, disorders of both calcium and phosphorus, as well as electrolyte disturbances, have been studied. The measurement of bone changes in endocrine dysfunction have been studied, particularly in patients with thyroid and parathyroid disorders. In parathyroidectomy, the measurement of total-body calcium, post-operatively, can indicate the degree of bone resorption. Skeletal metabolism and body composition in acromegaly and Cushing's disease have also been investigated by TBNAA. Levels of cadmium in liver and kidney have also been measured in vivo by prompt-gamma neutron activation and associated with hypertension, emphysema and cigarette smoking. Total-body nitrogen and potassium measurements serve as indices of muscle mass and are useful in studies of the interrelation of cancer, diet and nutrition. An essential requirement in these studies is the in-vivo measurement of changes in body composition, primarily revealed by nitrogen content. Currently the optimal method for measurement of total-body nitrogen is prompt-gamma neutron activation. There can be little question that in-vivo neutron activation is a useful addition to the techniques for medical research which provides new and previously unavailable information

  8. Wildland Fire Management Plan for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Green,T.

    2009-10-23

    This Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) updates the 2003 plan incorporating changes necessary to comply with DOE Order 450.1 and DOE P 450.4, Federal Wildland Fire Management Policy and Program Review; Wildland and Prescribed Fire Management Policy and implementation Procedures Reference Guide. This current plan incorporates changes since the original draft of the FMP that result from new policies on the national level. This update also removes references and dependence on the U.S. Fish & Wildlife Service and Department of the Interior, fully transitioning Wildland Fire Management responsibilities to BNL. The Department of Energy policy for managing wildland fires requires that all areas, managed by the DOE and/or its various contractors, that can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wild fire, operational, and prescribed fires. Fire management plans provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled, 'prescribed' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. This FMP will be reviewed periodically to ensure the fire program advances and evolves with the missions of the DOE and BNL. This Fire Management Plan is presented in a format that coverers all aspects specified by DOE guidance documents which are based on the national template for fire management plans adopted under the National Fire Plan. The DOE is one of the signatory agencies on the National Fire Plan. This FMP is to be used and implemented for the

  9. Association of pre-operative medication use with post-operative delirium in surgical oncology patients receiving comprehensive geriatric assessment.

    Science.gov (United States)

    Jeong, Young Mi; Lee, Eunsook; Kim, Kwang-Il; Chung, Jee Eun; In Park, Hae; Lee, Byung Koo; Gwak, Hye Sun

    2016-07-07

    Older patients undergoing surgery tend to have a higher frequency of delirium. Delirium is strongly associated with poor surgical outcomes. This study evaluated the association between pre-operative medication use and post-operative delirium (POD) in surgical oncology patients receiving comprehensive geriatric assessment (CGA). A total of 475 patients who were scheduled for cancer surgery and received CGA from January 2014 to June 2015 were included. Pre-operative medication review through CGA was conducted on polypharmacy (≥5 medications), delirium-inducing medications (DIMs), fall-inducing medications (FIMs), and potentially inappropriate medications (PIMs). POD was confirmed by psychiatric consultation, and DSM-V criteria were used for diagnosing delirium. The model fit of the prediction model was assessed by computing the Hosmer-Lemeshow goodness-of-fit test. Effect size was measured using the Nagelkerke R(2). Discrimination of the model was assessed by an analysis of the area under receiver operating curve (AUROC). Two models were constructed for multivariate analysis based on univariate analysis; model I included dementia and DIM in addition to age and sex, and model II included PIM instead of DIM of model I. Every one year increase of age increased the risk of POD by about 1.1-fold. DIM was a significant factor for POD after adjusting for confounders (AOR 12.78, 95 % CI 2.83-57.74). PIM was also a significant factor for POD (AOR 5.53, 95 % CI 2.03-15.05). The Hosmer-Lemeshow test results revealed good fits for both models (χ(2) = 3.842, p = 0.871 for model I and χ(2) = 8.130, p = 0.421 for model II). The Nagelkerke R(2) effect size and AUROC for model I was 0.215 and 0.833, respectively. Model II had the Nagelkerke R(2)effect size of 0.174 and AUROC of 0.819. These results suggest that pharmacists' comprehensive review for pre-operative medication use is critical for the post-operative outcomes like delirium in older patients.

  10. A survey of the high energy physics program at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Hahn, H.; Rau, R.R.; Wanderer, P.

    1977-01-01

    About fifteen years ago the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory began operating for high energy particle physics experiments. A wealth of important results has been published, capped by four discoveries which have changed the field dramatically. These discoveries are: the muon neutrino, γsub(μ); the strangeness minus three Ω - baryon; CP violation in K 0 decay; and recently the totally unpredicted J/psi particle. The experimental program has broadened, matured and increased in scope following a large improvement program at the AGS. Major developments included: replacement of the original 50 MeV linear accelerator injector by a modern 200 MeV linac; construction of two new experimental areas, one for neutrino experiments and the other for counter-spark chamber electronics experiments, with the philosophy that nearly all circulating protons would be extracted from the machine and directed onto targets external to the machine; raising the circulating proton intensity to a maximum of 10 13 protons, and installation of a new magnet supply allowing a cycle of 2.4 seconds with a 1 second flat-top, or a 40% duty cycle. The paper also describes a crucial function of any particle physics laboratory, the plans and research directed toward new facilities to make available new regions for particle physics research. (Auth.)

  11. Organization and Management of the International Space Station (ISS) Multilateral Medical Operations

    Science.gov (United States)

    Duncan, J. M.; Bogomolov, V. V.; Castrucci, F.; Koike, Y.; Comtois, J. M.; Sargsyan, A. E.

    2007-01-01

    The goal of this work is to review the principles, design, and function of the ISS multilateral medical authority and the medical support system of the ISS Program. Multilateral boards and panels provide operational framework, direct, and supervise the ISS joint medical operational activities. The Integrated Medical Group (IMG) provides front-line medical support of the crews. Results of ongoing activities are reviewed weekly by physician managers. A broader status review is conducted monthly to project the state of crew health and medical support for the following month. All boards, panels, and groups function effectively and without interruptions. Consensus prevails as the primary nature of decisions made by all ISS medical groups, including the ISS medical certification board. The sustained efforts of all partners have resulted in favorable medical outcomes of the initial fourteen long-duration expeditions. The medical support system appears to be mature and ready for further expansion of the roles of all Partners, and for the anticipated increase in the size of ISS crews.

  12. Operation of medical accelerator PATRO at Hyogo Ion Beam Medical Center

    International Nuclear Information System (INIS)

    Itano, A.; Akagi, T.; Higashi, A.; Fukushima, S.; Fujita, A.; Honda, Y.; Isa, H.; Nishikigouri, K.

    2004-01-01

    PATRO (Particle Accelerator for Therapy, Radiology and Oncology) is a medical accelerator facility for hadrontherapy of cancer at Hyogo Ion Beam Medical Center (HIBMC). Beam particles are proton (230 MeV) and carbon (320 MeV/u). After the beam commissioning and the tuning of irradiation system in 2000, we performed the clinical trials with proton and carbon beams from May 2001 until July 2002. We operated the accelerator for about 11,000 hours since the beginning of the beam tuning until the end of the clinical trials and for about 5,000 hours during the clinical trials. No serious troubles happened during the clinical trials. The stability and the reproducibility of the beams were well proved. (author)

  13. Task force St. Bernard: operational issues and medical management of a National Guard disaster response operation.

    Science.gov (United States)

    Bonnett, Carl J; Schock, Tony R; McVaney, Kevin E; Colwell, Christopher B; Depass, Christopher

    2007-01-01

    After Hurricane Katrina struck the Gulf Coast of the United States on 29 August 2005, it became obvious that the country was facing an enormous national emergency. With local resources overwhelmed, governors across the US responded by deploying thousands of National Guard soldiers and airmen. The National Guard has responded to domestic disasters due to natural hazards since its inception, but an event with the magnitude of Hurricane Katrina was unprecedented. The deployment of >900 Army National Guard soldiers to St. Bernard Parish, Louisiana in the aftermath of the Hurricane was studied to present some of the operational issues involved with providing medical support for this type of operation. In doing so, the authors attempt to address some of the larger issues of how the National Guard can be incorporated into domestic disaster response efforts. A number of unforeseen issues with regards to medical operations, medical supply, communication, preventive medicine, legal issues, and interactions with civilians were encountered and are reviewed. A better understanding of the National Guard and how it can be utilized more effectively in future disaster response operations can be developed.

  14. Brookhaven National Laboratory electron beam test stand

    International Nuclear Information System (INIS)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Prelec, K.; Snydstrup, L.

    1998-01-01

    The main purpose of the electron beam test stand (EBTS) project at the Brookhaven National Laboratory is to build a versatile device to develop technologies that are relevant for a high intensity electron beam ion source (EBIS) and to study the physics of ion confinement in a trap. The EBTS will have all the main attributes of EBIS: a 1-m-long, 5 T superconducting solenoid, electron gun, drift tube structure, electron collector, vacuum system, ion injection system, appropriate control, and instrumentation. Therefore it can be considered a short prototype of an EBIS for a relativistic heavy ion collider. The drift tube structure will be mounted in a vacuum tube inside a open-quotes warmclose quotes bore of a superconducting solenoid, it will be at room temperature, and its design will employ ultrahigh vacuum technology to reach the 10 -10 Torr level. The first gun to be tested will be a 10 A electron gun with high emission density and magnetic compression of the electron beam. copyright 1998 American Institute of Physics

  15. Geothermal materials development at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Kukacka, L.E. [Brookhaven National Lab., Upton, NY (United States)

    1997-12-31

    As part of the DOE/OGT response to recommendations and priorities established by industrial review of their overall R&D program, the Geothermal Materials Program at Brookhaven National Laboratory (BNL) is focusing on topics that can reduce O&M costs and increase competitiveness in foreign and domestic markets. Corrosion and scale control, well completion materials, and lost circulation control have high priorities. The first two topics are included in FY 1997 BNL activities, but work on lost circulation materials is constrained by budgetary limitations. The R&D, most of which is performed as cost-shared efforts with U.S. geothermal firms, is rapidly moving into field testing phases. FY 1996 and 1997 accomplishments in the development of lightweight CO{sub 2}-resistant cements for well completions; corrosion resistant, thermally conductive polymer matrix composites for heat exchange applications; and metallic, polymer and ceramic-based corrosion protective coatings are given in this paper. In addition, plans for work that commenced in March 1997 on thermally conductive cementitious grouting materials for use with geothermal heat pumps (GHP), are discussed.

  16. Charge exchange studies with Gold ions at the Brookhaven Booster and AGS

    International Nuclear Information System (INIS)

    Ahrens, L.A.; Hseuh, H.C.; Roser, T.

    1994-01-01

    Efficient acceleration of Gold ions to ll GeV/nucleon places strong constraints on the vacuum and also on the choice of thickness and material of the necessary stripping foils. Results of a number of detailed experimental studies performed with the Gold beam at the Brookhaven Booster and AGS to determine the relevant electron stripping and pick-up probabilities are presented. Of particular interest is the lifetime of the relatively low energy, partially stripped Gold beam in the Booster and the stripping efficiency to Helium-like AU +77 for injection into the AGS

  17. Medical support to military airborne training and operations.

    Science.gov (United States)

    Starkey, Kerry J; Lyon, J; Sigman, E; Pynn, H J; Nordmann, G

    2018-05-01

    Airborne operations enable large numbers of military forces to deploy on the ground in the shortest possible time. This however must be balanced by an increased risk of injury. The aim of this paper is to review the current UK military drop zone medical estimate process, which may help to predict the risk of potential injury and assist in planning appropriate levels of medical support. In spring 2015, a British Airborne Battlegroup (UKBG) deployed on a 7-week overseas interoperability training exercise in the USA with their American counterparts (USBG). This culminated in a 7-day Combined Joint Operations Access Exercise, which began with an airborne Joint Forcible Entry (JFE) of approximately 2100 paratroopers.The predicted number of jump-related injuries was estimated using Parachute Order Number 8 (PO No 8). Such injuries were defined as injuries occurring from the time the paratrooper exited the aircraft until they released their parachute harness on the ground. Overall, a total of 53 (2.5%) casualties occurred in the JFE phase of the exercise, lower than the predicted number of 168 (8%) using the PO No 8 tool. There was a higher incidence of back (30% actual vs 20% estimated) and head injuries (21% actual vs 5% estimated) than predicted with PO No 8. The current method for predicting the incidence of medical injuries after a parachute drop using the PO No 8 tool is potentially not accurate enough for current requirements. Further research into injury rate, influencing factors and injury type are urgently required in order to provide an evidence base to ensure optimal medical logistical and clinical planning for airborne training and operations in the future. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Risk-based priority scoring for Brookhaven National Laboratory environmental restoration programs

    International Nuclear Information System (INIS)

    Morris, S.C.; Meinhold, A.F.

    1995-05-01

    This report describes the process of estimating the risk associated with environmental restoration programs under the Brookhaven National Laboratory Office of Environmental Restoration. The process was part of an effort across all Department of Energy facilities to provide a consistent framework to communicate risk information about the facilities to senior managers in the DOE Office of Environmental Management to foster understanding of risk activities across programs. the risk evaluation was a qualitative exercise. Categories considered included: Public health and safety; site personnel safety and health; compliance; mission impact; cost-effective risk management; environmental protection; inherent worker risk; environmental effects of clean-up; and social, cultural, political, and economic impacts

  19. Testing of a cryogenic recooler heat exchanger at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Nicoletti, A.; Wu, K.C.

    1993-01-01

    Brookhaven National Laboratory has tested a recooler heat exchanger intended to be used in the cryogenic system of the Relativistic Heavy Ion Collider. The unit is required to transfer 225 Watts from a supercritical helium stream flowing at 100 g/s to a helium bath boiling at 4.25 K. Measurements made with heat loads of 50 to over 450 Watts on the unit indicate its cooling capacity is greater than 400 Watts, as expected, and it will be suitable for use in the RHIC ring. Presented are the modifications made to BNL's MAGCOOL test facility that were necessary for testing, test procedure, and recooler performance

  20. Future management of hazardous wastes generated at Brookhaven National Laboratory, Upton, New York. Environmental assessment

    International Nuclear Information System (INIS)

    1994-09-01

    This document assesses the potential environmental impacts of a variety of alternatives which could provide a Resource Conservation and Recovery Act (RCRA) permitted waste packaging and storage facility that would handle all hazardous, radioactive, and mixed wastes generated at Brookhaven National Laboratory (BNL) and would operate in full compliance with all federal, state, and local laws and regulations. Location of the existing Hazardous Waste Management Facility (HWMF) with respect to ground water and the site boundary, technical and capacity limitations, inadequate utilities, and required remediation of the area make the existing facility environmentally unacceptable for long term continued use. This Environmental Assessment (EA) describes the need for action by the Department of Energy (DOE). It evaluates the alternatives for fulfilling that need, including the alternative preferred by DOE, a no-action alternative, and other reasonable alternatives. The EA provides a general description of BNL and the existing environment at the current HWMF and alternative locations considered for a new Waste Management Facility (WMF). Finally, the EA describes the potential environmental impacts of the alternatives considered. The preferred alternative, also identified as Alternative D, would be to construct and operate a new WMF on land formerly occupied by barracks during Camp Upton operations, in an area north of Building 830 and the High Flux Beam Reactor/Alternating Gradient Synchrotron (AGS) recharge basins, east of North Railroad Street, and south of East Fifth Avenue. The purpose of this new facility would be to move all storage and transfer activities inside buildings and on paved and curbed areas, consolidate facilities to improve operations management, and provide improved protection of the environment

  1. Medical capability team: the clinical microsystem for combat healthcare delivery in counterinsurgency operations.

    Science.gov (United States)

    Clark, Susz; Van Steenvort, Jon K

    2008-01-01

    Today's operational environment in the support of counterinsurgency operations requires greater tactical and operational flexibility and diverse medical capabilities. The skills and organizations required for full spectrum medical operations are different from those of the past. Combat healthcare demands agility and the capacity for rapid change in clinical systems and processes to better support the counterinsurgency environment. This article proposes the Army Medical Department (AMEDD) develop and implement the medical capability team (MCT) for combat healthcare delivery. It discusses using the concept of the brigade combat team to develop medical capability teams as the unit of effectiveness to transform frontline care; provides a theoretical overview of the MCT as a "clinical microsystem"; discusses MCT leadership, training, and organizational support, and the deployment and employment of the MCT in a counterinsurgency environment. Additionally, this article proposes that the AMEDD initiate the development of an AMEDD Combat Training Center of Excellence to train and validate the MCTs. The complexity of combat healthcare demands an agile and campaign quality AMEDD with joint expeditionary capability in order to promote the best patient outcomes in a counterinsurgency environment.

  2. Summary of failure analysis activities at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Cowgill, M.G.; Czajkowski, C.J.; Franz, E.M.

    1996-10-01

    Brookhaven National Laboratory has for many years conducted examinations related to the failures of nuclear materials and components. These examinations included the confirmation of root cause analyses, the determination of the causes of failure, identification of the species that accelerate corrosion, and comparison of the results of nondestructive examinations with those obtained by destructive examination. The results of those examinations, which had previously appeared in various formats (formal and informal reports, journal articles, etc.), have been collected together and summarized in the present report. The report is divided into sections according to the general subject matter (for example, corrosion, fatigue, etc.). Each section presents summaries of the information contained in specific reports and publications, all of which are fully identified as to title, authors, report number or journal reference, date of publication, and FIN number under which the work was performed

  3. Characterization of the medical department of pharmaceutical companies operating in Portugal

    Directory of Open Access Journals (Sweden)

    Acílio Gala

    2017-04-01

    Full Text Available In a context of strong regulatory demands and high economic pressures and constraints, medical departments within pharmaceutical companies, have demonstrated its strategic relevance even though the functions to embrace are not globally consensual. In this context, a study that intended to analyse the management of medical activities, in pharmaceutical companies operating in Portugal, including allocated human resources and investment trends, was implemented. Quantitative information was collected through an electronic survey, in pharmaceutical companies with activity in Portugal. The analysis of the results supported the conclusion that the majority of the companies are affiliates of international companies and that 79% of them have formalized medical departments. The human resources of the medical departments of the participant companies include several professional classes, with predominance of pharmacists. Globally, the number of employees of the medical area has registered a systematic growth in the last years. It was also possible to conclude that the majority of the companies are increasing the investment in medical affairs activities. This study enables the understanding of these activities in pharmaceutical companies operating in Portugal, within the international panorama of pharmaceutical industry. It contributes to improve the knowledge about the relevance of medical departments while enabling the definition of novel pathways to increase the competiveness and sustainability of the companies.

  4. Deadline pressure and human error: a study of human failures on a particle accelerator at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Tiagha, E.A.

    1982-01-01

    The decline in industrial efficiency may be linked to decreased reliability of complex automatic systems. This decline threatens the viability of complex organizations in industrialized economies. Industrial engineering techniques that minimize system failure by increasing the reliability of systems hardware are well developed in comparison with those available to reduce human operator errors. The problem of system reliability and the associated costs of breakdown can be reduced if we understand how highly skilled technical personnel function in complex operations and systems. The purpose of this research is to investigate how human errors are affected by deadline pressures, technical communication and other socio-dynamic factors. Through the analysis of a technologically complex particle accelerator prototype at Brookhaven National Laboratory, two failure mechanisms: (1) physical defects in the production process and (2) human operator errors were identified. Two instruments were used to collect information on human failures: objective laboratory data and a human failure questionnaire. The results of human failures from the objective data were used to test for the deadline hypothesis and also to validate the human failure questionnaire. To explain why the human failures occurred, data were collected from a four-part, closed choice questionnaire administered to two groups of scientists, engineers, and technicians, working together against a deadline to produce an engineering prototype of a particle accelerator

  5. Radiation safety and operational health physics of hospital based medical cyclotrons

    International Nuclear Information System (INIS)

    Mukherjee, B.

    2002-01-01

    Full text: Compact, low energy, high current Medical Cyclotrons are now primarily used to produce large activities of short lived, neutron deficient, positron- emitting radioisotopes. These isotopes constitute the key ingredients of important PET (Positron Emission Tomography) radiopharmaceuticals used in diagnostic nuclear medicine. The PET-radioisotope producing Medical Cyclotrons are now increasingly installed in modern urban hospitals in many countries of the world. Modern Medical Cyclotrons run at a very high beam current (∼100-200 micro Amp) level and thereby produce intense fields of parasitic gamma rays and neutrons, causing the activation of cyclotron components, ambient air and radiation exposure to patients and members of the public. This report highlights the important operational aspects and the characteristics of the radiation fields produced by Medical Cyclotrons. The pathways of personnel radiation exposure are also analyzed. The above information constitutes the scientific basis of a sound operational health physics service, which is manifested in an effective dose reduction and an enhanced radiological safety of the Medical Cyclotron facility within the framework of ALARA

  6. Pulsed-neutron production at the Brookhaven 200-MeV linac

    International Nuclear Information System (INIS)

    Ward, T.E.; Alessi, J.; Brennan, J.; Grand, P.; Lankshear, R.; Montemurro, P.; Snead, C.L. Jr.; Tsoupas, N.

    1988-01-01

    The new 750-kV RFQ preinjector and double chopper system capable of selecting single nanosecond micropulses with repetition rates of 0.1--20 MHz has been installed at the Brookhaven 200-MeV proton linac. The micropulse intensity is approximately 1 x 10 9 p/μpulse. Neutron time-of-flight path lengths of 30--100 meter at 0/degree/, 12/degree/, 30/degree/, 45/degree/, 90/degree/ and 135/degree/ are available, as well as a zero degree swinger capable of an angular range of 0--25/degree/. Pulsed neutron beams of monoenergetic (p 7 Li → n 7 Be) and spallation (p 238 U → nx) sources will be discussed in the present paper, as well as detailing the chopped-beam capabilities. 11 refs., 5 figs., 1 tab

  7. Medical Support for Aircraft Disaster Search and Recovery Operations at Sea: the RSN Experience.

    Science.gov (United States)

    Teo, Kok Ann Colin; Chong, Tse Feng Gabriel; Liow, Min Han Lincoln; Tang, Kong Choong

    2016-06-01

    The maritime environment presents a unique set of challenges to search and recovery (SAR) operations. There is a paucity of information available to guide provision of medical support for SAR operations for aircraft disasters at sea. The Republic of Singapore Navy (RSN) took part in two such SAR operations in 2014 which showcased the value of a military organization in these operations. Key considerations in medical support for similar operations include the resultant casualty profile and challenges specific to the maritime environment, such as large distances of area of operations from land, variable sea states, and space limitations. Medical support planning can be approached using well-established disaster management life cycle phases of preparedness, mitigation, response, and recovery, which all are described in detail. This includes key areas of dedicated training and exercises, force protection, availability of air assets and chamber support, psychological care, and the forensic handling of human remains. Relevant lessons learned by RSN from the Air Asia QZ8501 search operation are also included in the description of these key areas. Teo KAC , Chong TFG , Liow MHL , Tang KC . Medical support for aircraft disaster search and recovery operations at sea: the RSN experience. Prehosp Disaster Med. 2016; 31(3):294-299.

  8. The Relativistic Heavy Ion Collider (RHIC) cryogenic system at Brookhaven National Laboratory: Review of the modifications and upgrades since 2002 and planned improvements

    International Nuclear Information System (INIS)

    Than, R.; Tuozzolo, Joseph; Sidi-Yekhlef, Ahmed; Ganni, Venkatarao; Knudsen, Peter; Arenius, Dana

    2008-01-01

    Brookhaven National Laboratory continues its multi-year program to improve the operational efficiency, reliability, and stability of the cryogenic system, which also resulted in an improved beam availability of the Relativistic Heavy Ion Collider (RHIC). This paper summarizes the work and changes made after each phase over the past four years to the present, as well as proposed future improvements. Power usage dropped from an initial 9.4 MW to the present 5.1 MW and is expected to drop below 5 MW after the completion of the remaining proposed improvements. The work proceeded in phases, balancing the Collider's schedule of operation, time required for the modifications and budget constraints. The main changes include process control, compressor oil removal and management, elimination of the use of cold compressors and two liquid-helium storage tanks, insulation of the third liquid-helium storage tank, compressor-bypass flow reduction and the addition of a load turbine (Joule-Thomson)

  9. Production capabilities in US nuclear reactors for medical radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Mirzadeh, S.; Callahan, A.P.; Knapp, F.F. Jr. (Oak Ridge National Lab., TN (United States)); Schenter, R.E. (Westinghouse Hanford Co., Richland, WA (United States))

    1992-11-01

    The availability of reactor-produced radioisotopes in the United States for use in medical research and nuclear medicine has traditionally depended on facilities which are an integral part of the US national laboratories and a few reactors at universities. One exception is the reactor in Sterling Forest, New York, originally operated as part of the Cintichem (Union Carbide) system, which is currently in the process of permanent shutdown. Since there are no industry-run reactors in the US, the national laboratories and universities thus play a critical role in providing reactor-produced radioisotopes for medical research and clinical use. The goal of this survey is to provide a comprehensive summary of these production capabilities. With the temporary shutdown of the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) in November 1986, the radioisotopes required for DOE-supported radionuclide generators were made available at the Brookhaven National Laboratory (BNL) High Flux Beam Reactor (HFBR). In March 1988, however, the HFBR was temporarily shut down which forced investigators to look at other reactors for production of the radioisotopes. During this period the Missouri University Research Reactor (MURR) played an important role in providing these services. The HFIR resumed routine operation in July 1990 at 85 MW power, and the HFBR resumed operation in June 1991, at 30 MW power. At the time of the HFBR shutdown, there was no available comprehensive overview which could provide information on status of the reactors operating in the US and their capabilities for radioisotope production. The obvious need for a useful overview was thus the impetus for preparing this survey, which would provide an up-to-date summary of those reactors available in the US at both the DOE-funded national laboratories and at US universities where service irradiations are currently or expected to be conducted.

  10. Production capabilities in US nuclear reactors for medical radioisotopes

    International Nuclear Information System (INIS)

    Mirzadeh, S.; Callahan, A.P.; Knapp, F.F. Jr.; Schenter, R.E.

    1992-11-01

    The availability of reactor-produced radioisotopes in the United States for use in medical research and nuclear medicine has traditionally depended on facilities which are an integral part of the US national laboratories and a few reactors at universities. One exception is the reactor in Sterling Forest, New York, originally operated as part of the Cintichem (Union Carbide) system, which is currently in the process of permanent shutdown. Since there are no industry-run reactors in the US, the national laboratories and universities thus play a critical role in providing reactor-produced radioisotopes for medical research and clinical use. The goal of this survey is to provide a comprehensive summary of these production capabilities. With the temporary shutdown of the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) in November 1986, the radioisotopes required for DOE-supported radionuclide generators were made available at the Brookhaven National Laboratory (BNL) High Flux Beam Reactor (HFBR). In March 1988, however, the HFBR was temporarily shut down which forced investigators to look at other reactors for production of the radioisotopes. During this period the Missouri University Research Reactor (MURR) played an important role in providing these services. The HFIR resumed routine operation in July 1990 at 85 MW power, and the HFBR resumed operation in June 1991, at 30 MW power. At the time of the HFBR shutdown, there was no available comprehensive overview which could provide information on status of the reactors operating in the US and their capabilities for radioisotope production. The obvious need for a useful overview was thus the impetus for preparing this survey, which would provide an up-to-date summary of those reactors available in the US at both the DOE-funded national laboratories and at US universities where service irradiations are currently or expected to be conducted

  11. CULTURAL RESOURCE MANAGEMENT PLAN FOR BROOKHAVEN NATIONAL LABORATORY.

    Energy Technology Data Exchange (ETDEWEB)

    DAVIS, M.

    2005-04-01

    The Cultural Resource Management Plan (CRMP) for Brookhaven National Laboratory (BNL) provides an organized guide that describes or references all facets and interrelationships of cultural resources at BNL. This document specifically follows, where applicable, the format of the U.S. Department of Energy (DOE) Environmental Guidelines for Development of Cultural Resource Management Plans, DOE G 450.1-3 (9-22-04[m1]). Management strategies included within this CRMP are designed to adequately identify the cultural resources that BNL and DOE consider significant and to acknowledge associated management actions. A principal objective of the CRMP is to reduce the need for additional regulatory documents and to serve as the basis for a formal agreement between the DOE and the New York State Historic Preservation Officer (NYSHPO). The BNL CRMP is designed to be a ''living document.'' Each section includes identified gaps in the management plan, with proposed goals and actions for addressing each gap. The plan will be periodically revised to incorporate new documentation.

  12. Space Technology - Game Changing Development NASA Facts: Autonomous Medical Operations

    Science.gov (United States)

    Thompson, David E.

    2018-01-01

    The AMO (Autonomous Medical Operations) Project is working extensively to train medical models on the reliability and confidence of computer-aided interpretation of ultrasound images in various clinical settings, and of various anatomical structures. AI (Artificial Intelligence) algorithms recognize and classify features in the ultrasound images, and these are compared to those features that clinicians use to diagnose diseases. The acquisition of clinically validated image assessment and the use of the AI algorithms constitutes fundamental baseline for a Medical Decision Support System that will advise crew on long-duration, remote missions.

  13. Seismic hazard studies for the high flux beam reactor at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Costantino, C.J.; Heymsfield, E.; Park, Y.J.; Hofmayer, C.H.

    1991-01-01

    This paper presents the results of a calculation to determine the site specific seismic hazard appropriate for the deep soil site at Brookhaven National Laboratory (BNL) which is to be used in the risk assessment studies being conducted for the High Flux Beam Reactor (HFBR). The calculations use as input the seismic hazard defined for the bedrock outcrop by a study conducted at Lawrence Livermore National Laboratory (LLNL). Variability in site soil properties were included in the calculations to obtain the seismic hazard at the ground surface and compare these results with those using the generic amplification factors from the LLNL study

  14. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source.

    Science.gov (United States)

    Kondo, K; Yamamoto, T; Sekine, M; Okamura, M

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (∼100 μA) with high charge (∼10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  15. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion source

    International Nuclear Information System (INIS)

    Kondo, K.; Okamura, M.; Yamamoto, T.; Sekine, M.

    2012-01-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (∼100 μA) with high charge (∼10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  16. Laser ion source with solenoid for Brookhaven National Laboratory-electron beam ion sourcea)

    Science.gov (United States)

    Kondo, K.; Yamamoto, T.; Sekine, M.; Okamura, M.

    2012-02-01

    The electron beam ion source (EBIS) preinjector at Brookhaven National Laboratory (BNL) is a new heavy ion-preinjector for relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory (NSRL). Laser ion source (LIS) is a primary ion source provider for the BNL-EBIS. LIS with solenoid at the plasma drift section can realize the low peak current (˜100 μA) with high charge (˜10 nC) which is the BNL-EBIS requirement. The gap between two solenoids does not cause serious plasma current decay, which helps us to make up the BNL-EBIS beamline.

  17. Pulsed-neutron production at the Brookhaven 200-MeV linac

    International Nuclear Information System (INIS)

    Ward, T.E.; Alessi, J.; Brennan, J.; Grand, P.; Lankshear, R.; Montemurro, P.; Snead, C.L. Jr.; Tsoupas, N.

    1989-01-01

    The new 750-kV RFQ preinjector and double chopper system capable of selecting single nanosecond micropulses with repetition rates of 0.1 to 20 MHz has been installed at the Brookhaven 200-MeV proton linac. The micropulse intensity is approximately 1 x 10 9 p/μpulse. Neutron time-of-flight path lengths of 30 to 100 meters at 0 degree, 12 degree, 30 degree, 45 degree, 90 degree and 135 degree are available as well as a zero-degree beam swinger capable of an angular range of 0 degree to 25 degree. Pulsed neutron beams of monoenergetic (p 7 Li → n 7 Be) and spallation (p 238 U → nx) sources will be discussed in the present paper as well as detailing the chopped-beam capabilities. 11 refs., 5 figs., 1 tab

  18. Report on the Brookhaven solar neutrino experiment

    International Nuclear Information System (INIS)

    Davis, R. Jr.; Evans, J.C. Jr.

    1976-01-01

    This report is intended as a brief statement of the recent developments and results of the Brookhaven Solar Neutrino Experiment communicated through Professor G. Kocharov to the Leningrad conference on active processes on the sun and the solar neutrino problem. The report summarizes the results of experiments performed over a period of 6 years, from April 1970 to January 1976. Neutrino detection depends upon the neutrino capture reaction 37 Cl(ν,e - ) 37 Ar producing the isotope 37 Ar (half life of 35 days). The detector contains 3.8 x 10 5 liters of C 2 Cl 4 (2.2 x 10 30 atoms of 37 Cl) and is located at a depth of 4400 meters of water equivalent (m.w.e.) in the Homestake Gold Mine at Lead, South Dakota, U.S.A. The procedures for extracting 37 Ar and the counting techniques used were described in previous reports. The entire recovered argon sample was counted in a small gas proportional counter. Argon-37 decay events were characterized by the energy of the Auger electrons emitted following the electron capture decay and by the rise-time of the pulse. Counting measurements were continued for a period sufficiently long to observe the decay of 37 Ar

  19. Cathode cooling systems for the magnetron and Penning H- sources: a progress report of work at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    McKenzie-Wilson, R.B.

    1977-01-01

    The magnetron/Penning H - sources being developed at Brookhaven National Laboratory have produced ion currents up to 1 A with pulse lengths of 10 ms. The pulse length is limited by heating of the cathode surface. Cathode thermal conditions were investigated and lead to the conclusion that a cathode cooling system must be capable of handling 3 kW cm -2 of heated cathode surface. A review of cooling fluid requirements coupled with an examination of possible cooling fluids, leads to the conclusion that demineralized water is a suitable cooling fluid when used under pressurized nucleated boiling conditions. A correlation is used to show that heat-flux of 1.25 kW cm -2 could be removed using current technology and that this heat flux may be extended to 3 kW cm -2 by use of the Hyper-Vapotron effect. The temperature of the working surface of the cathode may be varied over a small temperature range by varying the system pressure during operation

  20. Applications of nuclear techniques for in vivo body composition studies at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Cohn, S.H.; Ellis, K.J.; Vartsky, D.; Vaswani, A.N.; Wielopolski, L.

    1981-01-01

    A series of technical developments and their clinical applications in various nuclear technologies at Brookhaven National Laboratory is described. These include the development of a portable neutron activation facility for measuring cadmium in vivo in kidney and liver, a technique for the measurement of body iron utilizing nuclear resonant scattering of gamma rays, a non-invasive measure of the skeletal levels of lead by an x-ray fluorescence technique, and the development of a pulsed Van de Graaff generator as a source of pulsed neutrons for the measurement of lung silicon

  1. Applications of nuclear techniques for in vivo body composition studies at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Cohn, S.H.; Ellis, K.J.; Vartsky, D.; Vaswani, A.N.; Wielopolski, L.

    1981-01-01

    A series of technical developments and their clinical applications in various nuclear technologies at Brookhaven National Laboratory is described. These include the development of a portable neutron activation facility for measuring cadmium in vivo in kidney and liver, a technique for the measurement of body iron utilizing nuclear resonant scattering of gamma rays, a non-invasive measure of the skeletal levels of lead by an x-ray fluorescence technique, and the development of a pulsed Van de Graaff generator as a source of pulsed neutrons for the measurement of lung silicon. (ACR)

  2. Dioxins from medical waste incineration: Normal operation and transient conditions.

    Science.gov (United States)

    Chen, Tong; Zhan, Ming-xiu; Yan, Mi; Fu, Jian-ying; Lu, Sheng-yong; Li, Xiao-dong; Yan, Jian-hua; Buekens, Alfons

    2015-07-01

    Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are key pollutants in waste incineration. At present, incinerator managers and official supervisors focus only on emissions evolving during steady-state operation. Yet, these emissions may considerably be raised during periods of poor combustion, plant shutdown, and especially when starting-up from cold. Until now there were no data on transient emissions from medical (or hospital) waste incineration (MWI). However, MWI is reputed to engender higher emissions than those from municipal solid waste incineration (MSWI). The emission levels in this study recorded for shutdown and start-up, however, were significantly higher: 483 ± 184 ng Nm(-3) (1.47 ± 0.17 ng I-TEQ Nm(-3)) for shutdown and 735 ng Nm(-3) (7.73 ng I-TEQ Nm(-3)) for start-up conditions, respectively. Thus, the average (I-TEQ) concentration during shutdown is 2.6 (3.8) times higher than the average concentration during normal operation, and the average (I-TEQ) concentration during start-up is 4.0 (almost 20) times higher. So monitoring should cover the entire incineration cycle, including start-up, operation and shutdown, rather than optimised operation only. This suggestion is important for medical waste incinerators, as these facilities frequently start up and shut down, because of their small size, or of lacking waste supply. Forthcoming operation should shift towards much longer operating cycles, i.e., a single weekly start-up and shutdown. © The Author(s) 2015.

  3. Five year report on the medical follow up of Marshallese receiving special medical care related to 1954 Bravo fallout radiation (January 1992--1996)

    Energy Technology Data Exchange (ETDEWEB)

    Vaswani, A.N.; Howard, J.E.

    1999-06-01

    This is the 17th and final report of the Marshall Islands Medical Program as carried out by the Brookhaven National Laboratory (BNL). The purpose of these publications has been to provide information on the medical status of 253 Marshallese exposed to radiation fallout in 1954. The medical program fulfills a commitment to disclose unique medical information relevant to public health. Details of the Bravo thermonuclear accident that caused the exposure have been published. A 1955 article in the Journal of the American Medical Association, which described the acute medical effects on the population that required special medical care, remains a definitive and relevant description of events. Marshallese participation in this Congressionally mandated program is voluntary. Throughout the 44 years of the program, each participating individual`s relevant medical findings, laboratory data, disease morbidity, and mortality have been published in the BNL reports in a manner preserving patient confidentiality. In each report, there has been an attempt to interpret these findings and to infer the role of radiation exposure in their development. An equally important aspect of the reports has been the presentation of data that allows for analyses of the medical consequences of the Marshallese exposure.

  4. Five year report on the medical follow up of Marshallese receiving special medical care related to 1954 Bravo fallout radiation (January 1992 -1996)

    International Nuclear Information System (INIS)

    Vaswani, A.N.; Howard, J.E.

    1999-06-01

    This is the 17th and final report of the Marshall Islands Medical Program as carried out by the Brookhaven National Laboratory (BNL). The purpose of these publications has been to provide information on the medical status of 253 Marshallese exposed to radiation fallout in 1954. The medical program fulfills a commitment to disclose unique medical information relevant to public health. Details of the Bravo thermonuclear accident that caused the exposure have been published. A 1955 article in the Journal of the American Medical Association, which described the acute medical effects on the population that required special medical care, remains a definitive and relevant description of events. Marshallese participation in this Congressionally mandated program is voluntary. Throughout the 44 years of the program, each participating individual's relevant medical findings, laboratory data, disease morbidity, and mortality have been published in the BNL reports in a manner preserving patient confidentiality. In each report, there has been an attempt to interpret these findings and to infer the role of radiation exposure in their development. An equally important aspect of the reports has been the presentation of data that allows for analyses of the medical consequences of the Marshallese exposure

  5. Army Medical Department Leaders in Military Operations Other Than War

    National Research Council Canada - National Science Library

    Sadlon, Gary

    2000-01-01

    .... Likewise, the Army Medical Department (AMEDD) must insure its leaders, specifically those selected to deploy world-wide, have a more diverse skill set that enables them to fully operate within the full spectrum of scenarios...

  6. Brookhaven National Laboratory site environmental report for calendar year 1993

    International Nuclear Information System (INIS)

    Naidu, J.R.; Royce, B.A.

    1994-05-01

    This report documents the results of the Environmental Monitoring Program at BNL and presents summary information about environmental compliance for 1993. To evaluate the effect of BNL operations on the local environment, measurements of direct radiation, and a variety of radionuclides and chemical compounds in ambient air, soil, sewage effluent, surface water, ground water and vegetation were made at the BNL site and at sites adjacent to the Laboratory. Brookhaven National Laboratory's compliance with all applicable guides, standards, and limits for radiological and nonradiological emissions to the environment were evaluated. Among the permitted facilities, two instances, of pH exceedances were observed at recharge basins, possible related to rain-water run-off to these recharge basins. Also, the discharge from the Sewage Treatment Plant (STP) to the Peconic River exceeded on five occasions, three for residual chlorine and one each for iron and ammonia nitrogen. The chlorine exceedances were related to a malfunctioning hypochlorite dosing pump and ceased when the pump was repaired. While the iron and ammonia-nitrogen could be the result of disturbances to the sand filter beds during maintenance. The environmental monitoring data has identified site-specific contamination of ground water and soil. These areas are subject to Remedial Investigation/Feasibility Studies (RI/FS) under the Inter Agency Agreement (IAG). Except for the above, the environmental monitoring data has continued to demonstrate that compliance was achieved with applicable environmental laws and regulations governing emission and discharge of materials to the environment, and that the environmental impacts at BNL are minimal and pose no threat to the public or to the environment. This report meets the requirements of DOE Orders 5484. 1, Environmental Protection, Safety, and Health Protection Information reporting requirements and 5400.1, General Environmental Protection Programs

  7. Corrosion analysis of decommissioned carbon steel waste water tanks at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Soo, P.; Roberts, T.C.

    1995-07-01

    A corrosion analysis was carried out on available sections of carbon steels taken from two decommissioned radioactive waste water tanks at Brookhaven National Laboratory. One of the 100,000 gallon tanks suffered from a pinhole failure in the wall which was subsequently patched. From the analysis it was shown that this leak, and two adjacent leaks were initiated by a discarded copper heating coil that had been dropped into the tank during service. The failure mechanism is postulated to have been galvanic attack at points of contact between the tank structure and the coil. Other leaks in the two tanks are also described in this report

  8. Reasons for medical evacuations of soldiers serving in International Security Assistance Force (ISAF) operation in Afghanistan.

    Science.gov (United States)

    Korzeniewski, Krzysztof; Gregulski, Robert

    2014-01-01

    The article presents the results of a research study into the reasons for medical evacuations of Polish military personnel taking part in the International Security Assistance Force (ISAF) operation in Afghanistan from 2007 to 2013. The authors have analysed medical records of 485 soldiers who were medically evacuated out of a combat zone in Afghanistan for battle injuries, non-battle injuries and diseases. Each medically evacuated Polish soldier was subjected to statistical analysis. The study population comprised 25,974 soldiers assigned to the Polish Military Contingent Afghanistan in the given period. From 2007 to 2013, 1.9% of the Polish military personnel (n = 485) participating in the ISAF operation in Afghanistan were evacuated for medical reasons before the scheduled termination of their contract. 40.6% of all medical evacuations were due to battle injuries, 32.4% due to non-battle injuries, and 27.0% due to diseases. ISAF is an example of a combat operation, in which battle injuries remain the leading health problem in mission participants. 3 of 4 Polish soldiers who were medically evacuated from Afghanistan were no longer fit for military service in the area of operations due to the traumas they had suffered.

  9. Building a Smooth Medical Service for Operating Room Using RFID Technologies

    Directory of Open Access Journals (Sweden)

    Lun-Ping Hung

    2014-01-01

    Full Text Available Due to the information technology advancement, the feasibility for the establishment of mobile medical environments has been strengthened. Using RFID to facilitate the tracing of patients’ mobile position in hospital has attracted more attentions from researchers due to the demand on advanced features. Traditionally, the management of surgical treatment is generally manually operated and there is no consistent operating procedure for patients transferring among wards, surgery waiting rooms, operating rooms, and recovery rooms, resulting in panicky and urgent transferring work among departments and, thus, leading to delays and errors. In this paper, we propose a new framework using radio frequency identification (RFID technology for a mobilized surgical process monitoring system. Through the active tag, an application management system used before, during, and after the surgical processes has been proposed. The concept of signal level matrix, SLM, was proposed to accurately identify patients and dynamically track patients’ location. By updating patient’s information real-time, the preprocessing time needed for various tasks and incomplete transfers among departments can be reduced, the medical resources can be effectively used, unnecessary medical disputes can be reduced, and more comprehensive health care environment can be provided. The feasibility and effectiveness of our proposed system are demonstrated with a number of experimental results.

  10. ACCELERATED SITE TECHNOLOGY DEPLOYMENT COST AND PERFORMANCE REPORT COMPARABILITY OF ISOCS INSTRUMENT IN RADIONUCLIDE CHARACTERICATION AT BROOKHAVEN NATIONAL LABORATORY

    Energy Technology Data Exchange (ETDEWEB)

    KALB,P.; LUCKETT,L.; MILLER,K.; GOGOLAK,C.; MILIAN,L.

    2001-03-01

    This report describes a DOE Accelerated Site Technology Deployment project being conducted at Brookhaven National Laboratory to deploy innovative, radiological, in situ analytical techniques. The technologies are being deployed in support of efforts to characterize the Brookhaven Graphite Research Reactor (BGRR) facility, which is currently undergoing decontamination and decommissioning. This report focuses on the deployment of the Canberra Industries In Situ Object Counting System (ISOCS) and assesses its data comparability to baseline methods of sampling and laboratory analysis. The battery-operated, field deployable gamma spectrometer provides traditional spectra of counts as a function of gamma energy. The spectra are then converted to radionuclide concentration by applying innovative efficiency calculations using monte carlo statistical methods and pre-defined geometry templates in the analysis software. Measurement of gamma emitting radionuclides has been accomplished during characterization of several BGRR components including the Pile Fan Sump, Above Ground Ducts, contaminated cooling fans, and graphite pile internals. Cs-137 is the predominant gamma-emitting radionuclide identified, with smaller quantities of Co-60 and Am-241 detected. The Project used the Multi-Agency Radiation Survey and Site Investigation Manual guidance and the Data Quality Objectives process to provide direction for survey planning and data quality assessment. Analytical results have been used to calculate data quality indicators (DQI) for the ISOCS measurements. Among the DQIs assessed in the report are sensitivity, accuracy, precision, bias, and minimum detectable concentration. The assessment of the in situ data quality using the DQIs demonstrates that the ISOCS data quality can be comparable to definitive level laboratory analysis when the field instrument is supported by an appropriate Quality Assurance Project Plan. A discussion of the results obtained by ISOCS analysis of

  11. ACCELERATED SITE TECHNOLOGY DEPLOYMENT COST AND PERFORMANCE REPORT COMPARABILITY OF ISOCS INSTRUMENT IN RADIONUCLIDE CHARACTERICATION AT BROOKHAVEN NATIONAL LABORATORY

    International Nuclear Information System (INIS)

    KALB, P.; LUCKETT, L.; MILLER, K.; GOGOLAK, C.; MILIAN, L.

    2001-01-01

    This report describes a DOE Accelerated Site Technology Deployment project being conducted at Brookhaven National Laboratory to deploy innovative, radiological, in situ analytical techniques. The technologies are being deployed in support of efforts to characterize the Brookhaven Graphite Research Reactor (BGRR) facility, which is currently undergoing decontamination and decommissioning. This report focuses on the deployment of the Canberra Industries In Situ Object Counting System (ISOCS) and assesses its data comparability to baseline methods of sampling and laboratory analysis. The battery-operated, field deployable gamma spectrometer provides traditional spectra of counts as a function of gamma energy. The spectra are then converted to radionuclide concentration by applying innovative efficiency calculations using monte carlo statistical methods and pre-defined geometry templates in the analysis software. Measurement of gamma emitting radionuclides has been accomplished during characterization of several BGRR components including the Pile Fan Sump, Above Ground Ducts, contaminated cooling fans, and graphite pile internals. Cs-137 is the predominant gamma-emitting radionuclide identified, with smaller quantities of Co-60 and Am-241 detected. The Project used the Multi-Agency Radiation Survey and Site Investigation Manual guidance and the Data Quality Objectives process to provide direction for survey planning and data quality assessment. Analytical results have been used to calculate data quality indicators (DQI) for the ISOCS measurements. Among the DQIs assessed in the report are sensitivity, accuracy, precision, bias, and minimum detectable concentration. The assessment of the in situ data quality using the DQIs demonstrates that the ISOCS data quality can be comparable to definitive level laboratory analysis when the field instrument is supported by an appropriate Quality Assurance Project Plan. A discussion of the results obtained by ISOCS analysis of

  12. Ion Sources, Preinjectors and the Road to EBIS (459th Brookhaven Lecture)

    International Nuclear Information System (INIS)

    Alessi, James

    2010-01-01

    To meet the requirements of the scientific programs of the Relativistic Heavy Ion Collider and the NASA Space Radiation Lab, BNL's Collider-Accelerator Department needs a variety of ion sources. Although these sources are a relatively small and inexpensive part of an accelerator, they can have a big impact on the machine's overall performance. For the 459th Brookhaven Lecture, James Alessi will describe C-AD's long history of developing state-of-the-art ion sources for its accelerators, and its current process for source and pre-injector development. He will follow up with a discussion of the features and development status of EBIS, which, as the newest source and preinjector, is in the final stages of commissioning at the end of a five-year construction project.

  13. HOM identification by bead pulling in the Brookhaven ERL cavity

    CERN Document Server

    Hahn, H; Jain, Puneet; Johnson, Elliott C; Xu, Wencan

    2014-01-01

    Exploratory measurements of the Brookhaven Energy Recovery Linac (ERL) cavity at superconducting temperature produced a long list of high order modes (HOMs). The niobium 5-cell cavity is terminated at each end with HOM ferrite dampers that successfully reduce the Q-factors to levels required to avoid beam break up (BBU) instabilities. However, a number of un-damped resonances with Q≥106 were found at 4 K and their mode identification forms the focus of this paper. The approach taken here consists of bead pulling on a copper (Cu) replica of the ERL cavity with dampers involving various network analyzer measurements. Several different S21 transmission measurements are used, including those taken from the fundamental input coupler to the pick-up probe across the cavity, others between beam-position monitor probes in the beam tubes, and also between probes placed into the cells. The bead pull technique suitable for HOM identification with a metallic needle or dielectric bead is detailed. This paper presents the...

  14. [Beginners' operations and medical specialist standards : Avoidance of criminal liability and civil liability].

    Science.gov (United States)

    Schneider, H

    2018-05-16

    In all phases, patients are entitled to receive medical treatment according to medical specialist standards. This does not mean that patients necessarily have to be treated by a medical specialist. Operations performed by "beginners", e. g. assistant physicians, are permitted. However, there are increased liability risks, both for the specialist and the assistant physician. Furthermore, there are risks of criminal responsibility for causing bodily harm by negligence or negligent manslaughter. This article portrays the requirements of civil liability and criminal responsibility concerning beginners' operations on the basis of cases and judgments of the Federal Court and the Higher Regional Courts in Germany. Additionally, the reception of the jurisprudence by the relevant legal literature will be discussed. Jurisprudence and legal literature categorize breaches of duty of care. Assistant physicians can be subject to contributory negligence liabilities, while specialists can bear liabilities for negligent selection, organization or supervision. Responsible specialist and assistant physicians can protect themselves (and the patient) and avoid legal risks by only performing operations adequate to their educational level or by delegating operations to beginners and ensuring intervention by a specialist by supervision of the operation which is suitable to the assistant physician's level of education.

  15. Irvine-Michigan-Brookhaven (I.M.B.) nucleon decay search status report

    International Nuclear Information System (INIS)

    Bratton, C.B.; Gajewski, W.; Kropp, W.R.

    1981-01-01

    The Irvine-Michigan-Brookhaven collaboration is currently constructing a 8700 tonne water Cerenkov detector to measure, or establish a lower limit to, the nucleon lifetime. The detector, which should be complete by the middle of October, is located at a depth of 1670 m.w.e. in the Morton Salt Mine near Cleveland, Ohio. Activities during the past year have been dominated by the construction of the laboratory and of the phototube, electronic and software systems. In house tests of the phototubes and data acquisition chain have demonstrated their reliability, the feasibility of on-line rejection of cosmic ray muons, and have yielded information relevant to off-line methods of event reconstruction. This report will concentrate on these activities and point out where actual experience or measurement has confirmed or modified features of the proposed detector as described previously in several articles

  16. Medical Operational Challenges in the Expedition 16 Landing and Recovery

    Science.gov (United States)

    Moynihan, S.; Johnston, S. L.; Ilcus, L. S.; Shevchenko, V.

    2009-01-01

    On April 19, 2008 the crew of Expedition 16 left the International Space Station and returned to earth via their Soyuz TMA-11 capsule after 192 days on orbit. Their capsule experienced the second consecutive and third ballistic reentry in the last 10 TMA recoveries and landed approximately 260 miles (420 km) from the prime landing site. Issues: The purpose of this presentation will be to describe, not only the typical medical operational challenges faced by Flight Surgeons recovering a long duration crew from space, but also address the unique challenges that existed with the Expedition 16 landing and crew recovery. Nominal Soyuz recovery challenges include remote recovery sites with crew exposures to sleep shifting and fatigue, dehydration, hypothermia and hyperthermia, and rotational, sustained, and impact g-forces. These environmental factors coupled with the patho-physiologic neuro-vestibular and orthostatic intolerance changes that occur secondary to the crews reintroduction into the earth s gravity field will be detailed. Additional challenges that were unique to this expedition included a ballistic reentry with higher g-loads, the presence of fire outside of the capsule on landing, a contingency medical event of a ground support personnel, and loss of communications with the crew just prior to landing and during recovery operations. Conclusions: In spite of these unique challenges the Russian Search and Rescue Forces and Medical Support personnel along with U.S. Medical Support performed well together. Possible improvements in training and coordination will be discussed.

  17. Closed-loop approach for situation awareness of medical devices and operating room infrastructure

    Directory of Open Access Journals (Sweden)

    Rockstroh Max

    2015-09-01

    Full Text Available In recent years, approaches for information and control integration in the digital operating room have emerged. A major step towards an intelligent operating room and a cooperative technical environment would be autonomous adaptation of medical devices and systems to the surgical workflow. The OR staff should be freed from information seeking and maintenance tasks. We propose a closed-loop concept integrating workflow monitoring, processing and (semi-automatic interaction to bridge the gap between OR integration of medical devices and workflow-related information management.

  18. Aerial radiological survey of the Brookhaven National Laboratory and surrounding area, May 1980

    International Nuclear Information System (INIS)

    Hobaugh, J.L.; Steiner, P.A.

    1984-01-01

    An aerial radiological survey was performed from 15 to 18 May 1980 over approximately a 21-square-kilometer (8-square-mile) area surrounding the Brookhaven National Laboratory (BNL). BNL is located in the center of Suffolk County, Long Island, New York. All gamma radiation data were collected by flying north-south lines spaced 91 meters (300 feet) apart at an altitude of 61 meters (200 feet) above ground level. A total of 17 anomalous areas were identified. The dominant isotopes found over these areas were cesium-137, manganese-54, and cobalt-60. All anomalies identified by the aerial measurements were correlated to site activities and storage facilities. 4 references, 18 figures, 1 table

  19. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1. Volume 5: Analysis of core damage frequency from seismic events for plant operational state 5 during a refueling outage

    International Nuclear Information System (INIS)

    Budnitz, R.J.; Davis, P.R.; Ravindra, M.K.; Tong, W.H.

    1994-08-01

    In 1989 the US Nuclear Regulatory Commission (NRC) initiated an extensive program to examine carefully the potential risks during low-power and shutdown operations. The program included two parallel projects, one at Sandia National Laboratories studying a boiling water reactor (Grand Gulf), and the other at Brookhaven National Laboratory studying a pressurized water reactor (Surry Unit 1). Both the Sandia and Brookhaven projects have examined only accidents initiated by internal plant faults---so-called ''internal initiators.'' This project, which has explored the likelihood of seismic-initiated core damage accidents during refueling outage conditions, is complementary to the internal-initiator analyses at Brookhaven and Sandia. This report covers the seismic analysis at Grand Gulf. All of the many systems modeling assumptions, component non-seismic failure rates, and human effort rates that were used in the internal-initiator study at Grand Gulf have been adopted here, so that the results of the study can be as comparable as possible. Both the Sandia study and this study examine only one shutdown plant operating state (POS) at Grand Gulf, namely POS 5 representing cold shutdown during a refueling outage. This analysis has been limited to work analogous to a level-1 seismic PRA, in which estimates have been developed for the core-damage frequency from seismic events during POS 5. The results of the analysis are that the core-damage frequency for earthquake-initiated accidents during refueling outages in POS 5 is found to be quite low in absolute terms, less than 10 -7 /year

  20. [Design and Implementation of a Mobile Operating Room Information Management System Based on Electronic Medical Record].

    Science.gov (United States)

    Liu, Baozhen; Liu, Zhiguo; Wang, Xianwen

    2015-06-01

    A mobile operating room information management system with electronic medical record (EMR) is designed to improve work efficiency and to enhance the patient information sharing. In the operating room, this system acquires the information from various medical devices through the Client/Server (C/S) pattern, and automatically generates XML-based EMR. Outside the operating room, this system provides information access service by using the Browser/Server (B/S) pattern. Software test shows that this system can correctly collect medical information from equipment and clearly display the real-time waveform. By achieving surgery records with higher quality and sharing the information among mobile medical units, this system can effectively reduce doctors' workload and promote the information construction of the field hospital.

  1. Fallout: The experiences of a medical team in the care of a Marshallese population accidentally exposed to fallout radiation

    Energy Technology Data Exchange (ETDEWEB)

    Conard, R.A.

    1991-12-31

    This report presents an historical account of the experiences of the Brookhaven Medical team in the examination and treatment of the Marshallese people following their accidental exposure to radioactive fallout in 1954. This is the first time that a population has been heavily exposed to radioactive fallout, and even though this was a tragic mishap, the medical findings have provided valuable information for other accidents involving fallout such as the recent reactor accident at Chernobyl. Particularly important has been the unexpected importance of radioactive iodine in the fallout in producing thyroid abnormalities.

  2. Fallout: The experiences of a medical team in the care of a Marshallese population accidentally exposed to fallout radiation

    Energy Technology Data Exchange (ETDEWEB)

    Conard, R.A.

    1991-01-01

    This report presents an historical account of the experiences of the Brookhaven Medical team in the examination and treatment of the Marshallese people following their accidental exposure to radioactive fallout in 1954. This is the first time that a population has been heavily exposed to radioactive fallout, and even though this was a tragic mishap, the medical findings have provided valuable information for other accidents involving fallout such as the recent reactor accident at Chernobyl. Particularly important has been the unexpected importance of radioactive iodine in the fallout in producing thyroid abnormalities.

  3. Fallout: The experiences of a medical team in the care of a Marshallese population accidently exposed to fallout radiation

    Energy Technology Data Exchange (ETDEWEB)

    Conard, R.A.

    1992-09-01

    This report presents an historical account of the experiences of the Brookhaven Medical Team in the examination and treatment of the Marshallese people following their accidental exposure to radioactive fallout in 1954. This is the first time that a population has been heavily exposed to radioactive fallout, and even though this was a tragic mishap, the medical findings have provided valuable information for other accidents involving fallout such as the recent reactor accident at Chernobyl. Noteworthy has been the unexpected importance of radioactive iodine in the fallout in producing thyroid abnormalities.

  4. Fallout: The experiences of a medical team in the care of a Marshallese population accidently exposed to fallout radiation

    International Nuclear Information System (INIS)

    Conard, R.A.

    1992-09-01

    This report presents an historical account of the experiences of the Brookhaven Medical Team in the examination and treatment of the Marshallese people following their accidental exposure to radioactive fallout in 1954. This is the first time that a population has been heavily exposed to radioactive fallout, and even though this was a tragic mishap, the medical findings have provided valuable information for other accidents involving fallout such as the recent reactor accident at Chernobyl. Noteworthy has been the unexpected importance of radioactive iodine in the fallout in producing thyroid abnormalities

  5. Fallout: The experiences of a medical team in the care of a Marshallese population accidentally exposed to fallout radiation

    International Nuclear Information System (INIS)

    Conard, R.A.

    1991-01-01

    This report presents an historical account of the experiences of the Brookhaven Medical team in the examination and treatment of the Marshallese people following their accidental exposure to radioactive fallout in 1954. This is the first time that a population has been heavily exposed to radioactive fallout, and even though this was a tragic mishap, the medical findings have provided valuable information for other accidents involving fallout such as the recent reactor accident at Chernobyl. Particularly important has been the unexpected importance of radioactive iodine in the fallout in producing thyroid abnormalities

  6. Variables influencing medical student learning in the operating room.

    Science.gov (United States)

    Schwind, Cathy J; Boehler, Margaret L; Rogers, David A; Williams, Reed G; Dunnington, Gary; Folse, Roland; Markwell, Stephen J

    2004-02-01

    The operating room (OR) is an important venue where surgeons do much of medical student teaching and yet there has been little work evaluating variables that influence learning in this unique environment. We designed this study to identify variables that affected medical student learning in the OR. We developed a questionnaire based on surgery faculty observations of learning in the OR. The medical students completed the questionnaire on 114 learning episodes in the OR. Pearson correlation coefficient was used to establish the strength of association between various variables and the student's overall perception of learning. The students evaluated 27 variables that might impact their learning in the OR. Strong correlations were identified between the attending physician's attitude, interactions and teaching ability in the OR and the environment being conducive to learning. Surgical faculty behavior is a powerful determinant of student perceptions of what provides for a favorable learning environment in the OR.

  7. Highway accident involving radiopharmaceuticals near Brookhaven, Mississippi on December 3, 1983

    International Nuclear Information System (INIS)

    Mohr, P.B.; Mount, M.E.; Schwartz, M.W.

    1985-04-01

    A rear-end collision occurred between a passenger automobile and a luggage trailer carrying 84 packages, 76 of which contained radiopharmaceuticals, on US Highway 84 near Brookhaven, Mississippi on the afternoon of December 3, 1983. The purpose of this report is to document the mechanical circumstances of the accident, confirm the nature and quantity of radioactive materials involved, and assess the nature of the physical environment to which the packages were exposed and the response of the packages. The report consists of three major sections. The first deals wth the nature and circumstances of the accident and findings of fact. The second gives an accounting and description of the materials involved and the consequences of their exposure. The third gives an assessment and analysis of the mechanisms of damage and the conclusions which may be drawn from the investigation. 4 refs., 24 figs., 4 tabs

  8. In vivo neutron activation facility at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ma, R.; Yasumura, Seiichi; Dilmanian, F.A.

    1997-11-01

    Seven important body elements, C, N, Ca, P, K, Na, and Cl, can be measured with great precision and accuracy in the in vivo neutron activation facilities at Brookhaven National Laboratory. The facilities include the delayed-gamma neutron activation, the prompt-gamma neutron activation, and the inelastic neutron scattering systems. In conjunction with measurements of total body water by the tritiated-water dilution method several body compartments can be defined from the contents of these elements, also with high precision. In particular, body fat mass is derived from total body carbon together with total body calcium and nitrogen; body protein mass is derived from total body nitrogen; extracellular fluid volume is derived from total body sodium and chlorine; lean body mass and body cell mass are derived from total body potassium; and, skeletal mass is derived from total body calcium. Thus, we suggest that neutron activation analysis may be valuable for calibrating some of the instruments routinely used in clinical studies of body composition. The instruments that would benefit from absolute calibration against neutron activation analysis are bioelectric impedance analysis, infrared interactance, transmission ultrasound, and dual energy x-ray/photon absorptiometry.

  9. A JURIDICAL-ADMINISTRATIVE COMPARISON BETWEEN THE MILITARY AND THE MEDICAL OPERATION

    Directory of Open Access Journals (Sweden)

    Georgel RUSU

    2016-03-01

    Full Text Available To bring together the word operation and opera and/or accomplishing an opera is not at all improper. Defining a (military operation as ”the total amount of the military actions performed by large operative and strategic units, according to an unique plan, for attaining an operative or strategic objective....”[1], coldly and exhaustively developed along almost two pages, may provide sufficient arguments for correctly anchoring the action within the domain of military practice, in spite of the shortcoming of not having a more synthetic form, with valid landmarks for other disciplines, as well. Frequently, both the medical and the military operations exceed their routine, deserving artistic appreciations. It is not accidental that analysis and preparation of any military combat includes the field of military art, defined as ”a compounding part of the military science, a specialized domain of organization and management of armed conflicts. It includes both the principles, methods, procedures and rules for the preparation and development of military actions, and the personal endowments (talent, mastership, skill expected from the part of leaders and troops for attaining success in the battle...”[2] More than that, the operative art is defined as ”a component of military art ... created and developed as an intermediary domain between strategy and tactics...”[3]. Continuing to lay stress on the parallelism to which the study is devoted, the author considers that actions that may be related to or may be appreciated as possessing artistic characteristics occur even beyond the field of aesthetic or reparatory surgery. The definitions provided by medical dictionaries do not eliminate, yet encourage similarities. The operation is ”s.f./operation, (Lat. operatio, -onis = work, operation, derived from operari = to work, and opus, operis = labour, work, a medical act performed by the surgeon with his hands, by means of adequate instruments, for

  10. Aerial radiological survey of the Shoreham Nuclear Power Station and surrounding area Brookhaven, New York

    International Nuclear Information System (INIS)

    1984-03-01

    An aerial radiological survey was performed over the area surrounding the Shoreham Nuclear Power Station during 5 to 9 June 1983. The survey, which covered an area of 338 square kilometers (131 square miles), also encompassed the entire Brookhaven National Laboratory (BNL) facility. The highest radiation exposure rate, over 1 milliroentgen per hour (mR/h), was inferred from data measured directly over the BNL facility. This detected activity was due to the presence of cobalt-58, cobalt-60 and cesium-137, which was consistent with normal BNL operations. With the exception of the BNL facility, the only detected man-made radioactivity was found near a cottage in Moriches, New York and was due to the presence of cobalt-60. For the remainder of the survey area, the inferred radiation exposure rates varied generally from 6 to 12 microroentgens per hour (μR/h). The reported exposure rate values include an estimated cosmic ray contribution of 3.7 μR/h. Ground-based measurements, conducted concurrently with the aerial survey, were compared to the inferred aerial results. Pressurized ionization chamber readings and a group of soil samples were acquired from five locations within the survey area. The exposure rate values obtained from these measurements were consistent with those inferred from the aerial results. 11 references, 12 figures, 3 tables

  11. In-situ containment of buried waste at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Dwyer, B.P.; Heiser, J.; Stewart, W.; Phillips, S.

    1997-01-01

    The primary objective of this project was to further develop close-coupled barrier technology for the containment of subsurface waste or contaminant migration. A close-coupled barrier is produced by first installing a conventional cement grout curtain followed by a thin inner lining of a polymer grout. The resultant barrier is a cement polymer composite that has economic benefits derived from the cement and performance benefits from the durable and chemically resistant polymer layer. The technology has matured from a regulatory investigation of issues concerning barriers and barrier materials to a pilot-scale, multiple individual column injections at Sandia National Labs (SNL) to full scale demonstration. The feasibility of this barrier concept was successfully proven in a full scale 'cold test' demonstration at Hanford, WA. Consequently, a full scale deployment of the technology was conducted at an actual environmental restoration site at Brookhaven National Lab (BNL), Long Island, NY. This paper discusses the installation and performance of a technology deployment implemented at OU-1 an Environmental Restoration Site located at BNL

  12. The program of the ALARA Center at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.

    1993-01-01

    In 1984 the Brookhaven National Laboratory was asked by the Nuclear Regulatory Commission to set up a Center to monitor dose-reduction efforts in the US and abroad and to focus the industry's attention on ALARA. The paper summarizes the main work of the ALARA Center between 1984 and 1992. The Center maintains nine data bases for the NRC and the Nuclear Power Industry. These databases are constantly updated and access to them is provided through a personal computer and a modem and by periodic publications in the form of a newsletter and NUREG reports. Also described briefly are eight other projects related to dose-reduction at nuclear power plants that the Center has carried out for the NRC. Among these are projects that analyze the cost-effectiveness of engineering modifications, look at worldwide activities at dose reduction and compare US and foreign dose experience, examine high-dose worker groups and high-dose jobs, develop optimum techniques to control contamination at nuclear plants, and look at the doses being received by men and women in all sectors of the nuclear industry

  13. Seismic upgrading of the Brookhaven High Flux Beam Research Reactor

    International Nuclear Information System (INIS)

    Subudhi, M.

    1985-01-01

    In recent years the High Flux Beam Research (HFBR) reactor facility at Brookhaven National Laboratory (BNL) was upgraded from 40 to 50 MW power level. The reactor plant was built in the early sixties to the seismic design requirements of the period, using the static load approach. While the plant power level was upgraded, the seismic design was also improved according to current design criteria. This included the development of new floor response spectra for the facility and an overall seismic analysis of those systems important to the safe shutdown of the reactor. Items included in the reanalysis are the containment building with its internal structure, the piping systems, tanks, equipment, and heat exchangers. This paper describes the procedure utilized in developing the floor response spectra for the existing facility. Also included in the paper are the findings and recommendations, based on the seismic analysis, regarding the seismic adequacy of structural and mechanical systems vital to achieving the safe shutdown of the reactor. 11 references, 4 figures, 1 table

  14. 47 CFR 95.1119 - Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band.

    Science.gov (United States)

    2010-10-01

    ... devices operating in the 608-614 MHz band. For a wireless medical telemetry device operating within the... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band. 95.1119 Section 95.1119 Telecommunication FEDERAL...

  15. Modifying Post-Operative Medical Care after EBV Implant May Reduce Pneumothorax Incidence.

    Directory of Open Access Journals (Sweden)

    Dominik Herzog

    Full Text Available Endoscopic lung volume reduction (ELVR with valves has been shown to improve COPD patients with severe emphysema. However, a major complication is pneumothoraces, occurring typically soon after valve implantation, with severe consequences if not managed promptly. Based on the knowledge that strain activity is related to a higher risk of pneumothoraces, we asked whether modifying post-operative medical care with the inclusion of strict short-term limitation of strain activity is associated with a lower incidence of pneumothorax.Seventy-two (72 emphysematous patients without collateral ventilation were treated with bronchial valves and included in the study. Thirty-two (32 patients received standard post-implantation medical management (Standard Medical Care (SMC, and 40 patients received a modified medical care that included an additional bed rest for 48 hours and cough suppression, as needed (Modified Medical Care (MMC.The baseline characteristics were similar for the two groups, except there were more males in the SMC cohort. Overall, ten pneumothoraces occurred up to four days after ELVR, eight pneumothoraces in the SMC, and only two in the MMC cohorts (p=0.02. Complicated pneumothoraces and pneumothoraces after upper lobe treatment were significantly lower in MMC (p=0.02. Major clinical outcomes showed no significant differences between the two cohorts.In conclusion, modifying post-operative medical care to include bed rest for 48 hours after ELVR and cough suppression, if needed, might reduce the incidence of pneumothoraces. Prospective randomized studies with larger numbers of well-matched patients are needed to confirm the data.

  16. Operating Dedicated Data Centers - Is It Cost-Effective?

    Science.gov (United States)

    Ernst, M.; Hogue, R.; Hollowell, C.; Strecker-Kellog, W.; Wong, A.; Zaytsev, A.

    2014-06-01

    The advent of cloud computing centres such as Amazon's EC2 and Google's Computing Engine has elicited comparisons with dedicated computing clusters. Discussions on appropriate usage of cloud resources (both academic and commercial) and costs have ensued. This presentation discusses a detailed analysis of the costs of operating and maintaining the RACF (RHIC and ATLAS Computing Facility) compute cluster at Brookhaven National Lab and compares them with the cost of cloud computing resources under various usage scenarios. An extrapolation of likely future cost effectiveness of dedicated computing resources is also presented.

  17. Skylab IMSS checklist application study for emergency medical care. [emergency medical care operations involving the use and operation of the portable ambulance module

    Science.gov (United States)

    Carl, J. G.; Furukawa, S.

    1975-01-01

    A manual is presented that provides basic technical documentation to support the operation and utilization of the Portable Ambulance Module (PAM) in the field. The PAM is designed to be used for emergency resuscitation and victim monitoring. The functions of all the controls, displays, and stowed equipment of the unit are defined. Supportive medical and physiological data in those areas directly related to the uses of the PAM unit are presented.

  18. Operational health and physics service during the maintenance of the Australian National Medical Cyclotron

    International Nuclear Information System (INIS)

    Mukherjee, B.

    1994-01-01

    Modern Medical Cyclotrons use intense beams of high energy protons or deuterons to produce large activities of short and medium lived radionuclides. After continuous operation for prolonged periods the Cyclotron components become activated through various nuclear interactions therefore, the risk of personal radiation hazard while handling such activated cyclotron components is high. This paper describes all operational aspects of the Health Physics service evolved during the first preventative maintenance program of the Australian National Medical Cyclotron, which took place in June 1993. 5 refs., 3 tabs., 2 figs

  19. Initial experiments with the Nevis Cyclotron, the Brookhaven Cosmotron, the Brookhaven AGS and their effects on high energy physics

    International Nuclear Information System (INIS)

    Lindenbaum, S.J.

    1988-01-01

    The first experiment at the Nevis Cyclotron by Bernardini, Booth and Lindenbaum demonstrated that nuclear stars are produced by a nucleon-nucleon cascade within the nucleon. This solved a long standing problem in Cosmic rays and made it clear that where they overlap cosmic ray investigation would not be competitive with accelerator investigations. The initial experiments at the Brookhaven Cosmotron by Lindenbaum and Yuan demonstrated that low energy pion nucleon scattering and pion production were unexpectedly mostly due to excitation of the isotopic spin = angular momentum = 3/2 isobaric state of the nucleon. This contradicted the Fermi statistical theory and led to the Isobar model proposed by the author and a collaborator. The initial experiments at the AGS by the author and collaborators demonstrated that the Pomeronchuck Theorem would not come true till at least several hundred GeV. These scattering experiments led to the development of the ''On-line Computer Technique'' by the author and collaborators which is now the almost universal technique in high energy physics. The first accomplishment which flowed from this technique led to contradiction of the Regge pole theory as a dynamical asymptotic theory, by the author and collaborators. The first critical experimental proof of the forward dispersion relation in strong interactions was accomplished by the author and collaborators. They were then used as a crystal ball to predict that ''Asymptopia''---the theoretically promised land where all asymptotic theorems come true---would not be reached till at least 25,000 BeV and probably not before 1,000,000 BeV. 26 refs., 11 figs., 2 tabs

  20. Summary of proposed approach for deriving cleanup guidelines for radionuclides in soil at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1996-11-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL`s Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory, carried out under an Interagency Agreement (IAG) with the United States Department of Energy (DOE), the United States Environmental Protection Agency (EPA) and the New York State Department of Environmental Conservation (NYSDEC). The objective of this paper is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL.

  1. Summary of proposed approach for deriving cleanup guidelines for radionuclides in soil at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

    1996-11-01

    Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL's Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory, carried out under an Interagency Agreement (IAG) with the United States Department of Energy (DOE), the United States Environmental Protection Agency (EPA) and the New York State Department of Environmental Conservation (NYSDEC). The objective of this paper is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL

  2. Effect of the solenoid in various conditions of the laser ion source at Brookhaven National Laboratory

    Science.gov (United States)

    Ikeda, S.; Kumaki, M.; Kanesue, T.; Okamura, M.

    2016-02-01

    In the laser ion source (LIS) at the Brookhaven National Laboratory (BNL), a solenoid is used to guide the laser ablation plasma and modulate the extracted beam current. Many types of ion species are guided. In some cases, the plasma plume is injected into the solenoid away from the solenoidal axis. To investigate the effects of the solenoid on the beam extracted from the plasma that has different properties, the beam current was measured in the setup of the LIS at the BNL. The beam current of Li, Al, Si, Fe, and Au increased when the magnetic field was applied. For most of the species the peak current and the total charge within a single beam pulse increased around 10 times with a magnetic field less than 100 G. In addition, for some species the rate of increase of the peak currents became smaller when the magnetic flux densities were larger than certain values depending on the species. In this case, the current waveforms were distorted. At the same magnetic field value, the field was more effective on lighter species than on heavier ones. When plasma was injected offset from the axis of the solenoid, peak current and total charge became half of those without offset. The experimental data are useful for the operation of the LIS at the BNL.

  3. Effect of the solenoid in various conditions of the laser ion source at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Ikeda, S.; Kumaki, M.; Kanesue, T.; Okamura, M.

    2016-01-01

    In the laser ion source (LIS) at the Brookhaven National Laboratory (BNL), a solenoid is used to guide the laser ablation plasma and modulate the extracted beam current. Many types of ion species are guided. In some cases, the plasma plume is injected into the solenoid away from the solenoidal axis. To investigate the effects of the solenoid on the beam extracted from the plasma that has different properties, the beam current was measured in the setup of the LIS at the BNL. The beam current of Li, Al, Si, Fe, and Au increased when the magnetic field was applied. For most of the species the peak current and the total charge within a single beam pulse increased around 10 times with a magnetic field less than 100 G. In addition, for some species the rate of increase of the peak currents became smaller when the magnetic flux densities were larger than certain values depending on the species. In this case, the current waveforms were distorted. At the same magnetic field value, the field was more effective on lighter species than on heavier ones. When plasma was injected offset from the axis of the solenoid, peak current and total charge became half of those without offset. The experimental data are useful for the operation of the LIS at the BNL

  4. Effect of the solenoid in various conditions of the laser ion source at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, S., E-mail: ikeda.s.ae@m.titech.ac.jp [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, Yokohama, Kanagawa 216-8502 (Japan); Nishina Center for Accelerator-Based Science, RIKEN, Wako, Saitama 351-0108 (Japan); Kumaki, M. [Nishina Center for Accelerator-Based Science, RIKEN, Wako, Saitama 351-0108 (Japan); Kanesue, T.; Okamura, M. [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973-5000 (United States)

    2016-02-15

    In the laser ion source (LIS) at the Brookhaven National Laboratory (BNL), a solenoid is used to guide the laser ablation plasma and modulate the extracted beam current. Many types of ion species are guided. In some cases, the plasma plume is injected into the solenoid away from the solenoidal axis. To investigate the effects of the solenoid on the beam extracted from the plasma that has different properties, the beam current was measured in the setup of the LIS at the BNL. The beam current of Li, Al, Si, Fe, and Au increased when the magnetic field was applied. For most of the species the peak current and the total charge within a single beam pulse increased around 10 times with a magnetic field less than 100 G. In addition, for some species the rate of increase of the peak currents became smaller when the magnetic flux densities were larger than certain values depending on the species. In this case, the current waveforms were distorted. At the same magnetic field value, the field was more effective on lighter species than on heavier ones. When plasma was injected offset from the axis of the solenoid, peak current and total charge became half of those without offset. The experimental data are useful for the operation of the LIS at the BNL.

  5. New newtron time-of-flight (NTOF) facilities at the Brookhaven 200-MeV Linac

    International Nuclear Information System (INIS)

    Ward, T.E.; Alessi, J.; Brennan, J.; Grand, P.; Lankshear, R.; Snead, C.L.; Tsoupas, N.; Zucker, M.

    1988-01-01

    The installation of a new beam chopper and radio-frequency quadrupole (RFQ) preinjector (750 keV) at the Brookhaven National Laboratory (BNL) 200-MeV Linac will enable single micropulse selection (pulse width 9 pμ pulse with dc-average beam currents of 50 nA-1 μA routinely available. The NTOF facilities consists of 30-100 meter flight paths at angles of 0, 12, 30, 45, 90, and 135/degree/. Lower energies of 93, 117, 139, 161, and 181 MeV are also available as well as polarized beams at much reduced intensities. The present paper describes the new facilities, and the capabilities of future improvements and upgrades, for use in the BNL intermediate energy (p,n) experimental program. 7 refs., 2 figs., 1 tab

  6. Operating dedicated data centers – is it cost-effective?

    International Nuclear Information System (INIS)

    Ernst, M; Hogue, R; Hollowell, C; Strecker-Kellog, W; Wong, A; Zaytsev, A

    2014-01-01

    The advent of cloud computing centres such as Amazon's EC2 and Google's Computing Engine has elicited comparisons with dedicated computing clusters. Discussions on appropriate usage of cloud resources (both academic and commercial) and costs have ensued. This presentation discusses a detailed analysis of the costs of operating and maintaining the RACF (RHIC and ATLAS Computing Facility) compute cluster at Brookhaven National Lab and compares them with the cost of cloud computing resources under various usage scenarios. An extrapolation of likely future cost effectiveness of dedicated computing resources is also presented.

  7. BLIP

    International Nuclear Information System (INIS)

    Stang, L.G. Jr.

    1976-01-01

    The operation of the Brookhaven Linac Isotope Producer (BLIP) is discussed. Topics covered include targets, target holders, linac specifications, beam transport, and current production performance. The use of the BLIP is confined exclusively to the development of radionuclides that are, or should be, of medical interest, and the facility is moving rapidly into a self-supporting state from the income of the products

  8. Heat leak testing of a superconducting RHIC dipole magnet at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    DeLalio, J.T.; Brown, D.P.; Sondericker, J.H.

    1993-01-01

    Brookhaven National Laboratory is currently performing heat load tests on a superconducting dipole magnet. The magnet is a prototype of the 360, 8 cm bore, arc dipole magnets that will be used in the Relativistic Heavy Ion Collider (RMC). An accurate measurement of the heat load is needed to eliminate cumulative errors when determining the REUC cryogenic system load requirements. The test setup consists of a dipole positioned between two quadrupoles in a common vacuum tank and heat shield. Piping and instrumentation are arranged to facilitate measurement of the heat load on the primary 4.6 K magnet load and the secondary 55 K heat shield load. Initial results suggest that the primary heat load is well below design allowances. The secondary load was found to be higher than estimated, but remained close to the budgeted amount. Overall, the dipole performed to specifications

  9. A Medical Logistics Officer Training Needs Assessment Utilizing Feedback from Operation Iraqi Freedom

    National Research Council Canada - National Science Library

    Waddick, James L

    2004-01-01

    ... their missions during the initial Operation Iraqi Freedom deployment (OIF 1). Additionally, the study sought to identify the potential benefit of additional training on key medical logistics tasks and training events...

  10. 47 CFR 95.1121 - Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427...

    Science.gov (United States)

    2010-10-01

    ... wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. Due to the critical... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. 95.1121 Section 95.1121...

  11. Deployment of field hospitals to disaster regions: Insights from ten medical relief operations spanning three decades.

    Science.gov (United States)

    Naor, Michael; Heyman, Samuel N; Bader, Tarif; Merin, Ofer

    2017-01-01

    The Israeli Defense Force (IDF) Medical Corps developed a model of airborne field hospital. This model was structured to deal with disaster settings, requiring self-sufficiency, innovation and flexible operative mode in the setup of large margins of uncertainty regarding the disaster environment. The current study is aimed to critically analyze the experience, gathered in ten such missions worldwide. Interviews with physicians who actively participated in the missions from 1988 until 2015 as chief medical officers combined with literature review of principal medical and auxiliary publications in order to assess and integrate information about the assembly of these missions. A body of knowledge was accumulated over the years by the IDF Medical Corps from deploying numerous relief missions to both natural (earthquake, typhoon, and tsunami), and man-made disasters, occurring in nine countries (Armenia, Rwanda, Kosovo, Turkey, India, Haiti, Japan, Philippines, and Nepal). This study shows an evolutionary pattern with improvements implemented from one mission to the other, with special adaptations (creativity and improvisation) to accommodate logistics barriers. The principals and operative function for deploying medical relief system, proposed over 20 years ago, were challenged and validated in the subsequent missions of IDF outlined in the current study. These principals, with the advantage of the military infrastructure and the expertise of drafted civilian medical professionals enable the rapid assembly and allocation of highly competent medical facilities in disaster settings. This structure model is to large extent self-sufficient with a substantial operative flexibility that permits early deployment upon request while the disaster assessment and definition of needs are preliminary.

  12. Neutron data compilation. Report of a Panel sponsored by the International Atomic Energy Agency and held in Brookhaven, 10-14 February 1969

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1969-02-15

    The IAEA organized and convened a Panel on Neutron Data Compilation. This Panel was organized by the Agency following the recommendations made by the International Nuclear Data Committee (INDC) which agreed that a general review of world neutron data compilation activities was desirable. In this context neutron data compilation encompasses the collection, storage and dissemination of bibliographic information and of qualitative and numerical data on the interaction of neutrons with nuclei and atoms for all incident energies. Such information and data have important applications in low energy neutron physics and many important. areas of nuclear technology. The principal objective of the Panel on Neutron Data Compilation, Which was held at Brookhaven National Laboratory during 10-14 February 1969, was to review how the world's principal data centers located at Brookhaven, Saclay, Obninsk and Vienna could ideally meet the demands and needs of experimental and theoretical neutron physicists, evaluators, reactor physicists as well as other existing and potential users. Fourteen papers were considered during formal sessions of the Panel and are reported on the following pages. The members of the Panel separated into five working groups to consider specific terms of references and make recommendations. Their reports were discussed.

  13. Lessons from the organisation of the UK medical services deployed in support of Operation TELIC (Iraq) and Operation HERRICK (Afghanistan).

    Science.gov (United States)

    Bricknell, Martin C M; Nadin, M

    2017-08-01

    This paper provides the definitive record of the UK Defence Medical Services (DMS) lessons from the organisation of medical services in support of Operation (Op) TELIC (Iraq) and Op HERRICK (Afghanistan). The analysis involved a detailed review of the published academic literature, internal post-operational tour reports and post-tour interviews. The list of lessons was reviewed through three Military Judgement Panel cycles producing the single synthesis ' the golden thread ' and eight ' silver bullets ' as themes to institutionalise the learning to deliver the golden thread. One additional theme, mentoring indigenous healthcare systems and providers, emerged as a completely new capability requirement. The DMS has established a programme of work to implement these lessons. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Measurement of ac electrical characteristics of SSC dipole magnets at Brookhaven

    International Nuclear Information System (INIS)

    Smedley, K.

    1992-04-01

    The SSC collider is designed to have circumference of 87 km. The superconducting magnets along the collider ring are grouped into ten sectors. Each sector, a string of average length of 8.7 km,m is powered by one power source located near the center of the sector. Because of the alternating-current (ac) electrical characteristics of the magnets, the power supply ripple currents and transients form a time and space distribution in the magnet string which affects particle motions. Additionally, since the power supply load is a magnet string, the current regulation loop design is highly dependent upon the ac electrical characteristics of the magnets. A means is needed to accurately determine the ac electrical characteristics of the superconducting magnets. The ac characteristics of magnets will be used to predict the ripple distribution of the long string of superconducting magnets. Magnet ac characteristics can also provide necessary information for the regulation loop design. This paper presents a method for measuring the ac characteristics of superconducting magnets. Two collider dipole magnets, one superconducting and one at room temperature, were tested at Brookhaven National Lab

  15. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... Medical Student Core Curriculum ACS/ASE Medical Student Simulation-Based Surgical Skills Curriculum Cancer Education Cancer Education ... Surgeons Education Patients and Family Skills Programs Your Lung Operation Your Lung Operation DVD After Your Operation ...

  16. The Shape and Flow of Heavy Ion Collisions (490th Brookhaven Lecture)

    Energy Technology Data Exchange (ETDEWEB)

    Schenke, Bjoern [BNL Physics Department

    2014-12-18

    The sun can’t do it, but colossal machines like the Relativistic Heavy Ion Collider (RHIC) at Brookhaven Lab and Large Hadron Collider (LHC) in Europe sure can. Quarks and gluons make up protons and neutrons found in the nucleus of every atom in the universe. At heavy ion colliders like RHIC and the LHC, scientists can create matter more than 100,000 times hotter than the center of the sun—so hot that protons and neutrons melt into a plasma of quarks and gluons. The particle collisions and emerging quark-gluon plasma hold keys to understanding how these fundamental particles interact with each other, which helps explain how everything is held together—from atomic nuclei to human beings to the biggest stars—how all matter has mass, and what the universe looked like microseconds after the Big Bang. Dr. Schenke discusses theory that details the shape and structure of heavy ion collisions. He will also explain how this theory and data from experiments at RHIC and the LHC are being used to determine properties of the quark-gluon plasma.

  17. National synchrotron light source guidelines for the conduct of operations

    International Nuclear Information System (INIS)

    Buckley, M.

    1998-01-01

    To improve the quality and uniformity of operations at the Department of Energy's facilities, the DOE issued Order 5480.19 ''Conduct of Operations Requirements at DOE facilities.'' This order recognizes that the success of a facility's mission critically depends upon a high level of performance by its personnel and equipment. This performance can be severely impaired if the facility's Conduct of Operations pays inadequate attention to issues of organization, safety, health, and the environment. These guidelines are Brookhaven National Laboratory's and the National Synchrotron Light Source's acknowledgement of the principles of Conduct of Operations and the response to DOE Order 5480.19. These guidelines cover the following areas: (1) operations organization and administration; (2) shift routines and operating practices; (3) control area activities; (4) communications; (5) control of on-shift training; (6) investigation of abnormal events; (7) notifications; (8) control of equipment and system studies; (9) lockouts and tagouts; (10) independent verification; (11) log-keeping; (12) operations turnover; (13) operations aspects of facility process control (14) required reading; (15) timely orders to operators; (16) operations procedures; (17) operator aid posting; and (18) equipment sizing and labeling

  18. NATURAL RESOURCE MANAGEMENT PLAN FOR BROOKHAVEN NATIONAL LABORATORY.

    Energy Technology Data Exchange (ETDEWEB)

    GREEN,T.ET AL.

    2003-12-31

    Brookhaven National Laboratory (BNL) is located near the geographic center of Long Island, New York. The Laboratory is situated on 5,265 acres of land composed of Pine Barrens habitat with a central area developed for Laboratory work. In the mid-1990s BNL began developing a wildlife management program. This program was guided by the Wildlife Management Plan (WMP), which was reviewed and approved by various state and federal agencies in September 1999. The WMP primarily addressed concerns with the protection of New York State threatened, endangered, or species of concern, as well as deer populations, invasive species management, and the revegetation of the area surrounding the Relativistic Heavy Ion Collider (RHIC). The WMP provided a strong and sound basis for wildlife management and established a basis for forward motion and the development of this document, the Natural Resource Management Plan (NRMP), which will guide the natural resource management program for BNL. The body of this plan establishes the management goals and actions necessary for managing the natural resources at BNL. The appendices provide specific management requirements for threatened and endangered amphibians and fish (Appendices A and B respectively), lists of actions in tabular format (Appendix C), and regulatory drivers for the Natural Resource Program (Appendix D). The purpose of the Natural Resource Management Plan is to provide management guidance, promote stewardship of the natural resources found at BNL, and to integrate their protection with pursuit of the Laboratory's mission. The philosophy or guiding principles of the NRMP are stewardship, adaptive ecosystem management, compliance, integration with other plans and requirements, and incorporation of community involvement, where applicable.

  19. Continuously Operating Biosensor and Its Integration into a Hermetically Sealed Medical Implant

    Directory of Open Access Journals (Sweden)

    Mario Birkholz

    2016-10-01

    Full Text Available An integration concept for an implantable biosensor for the continuous monitoring of blood sugar levels is presented. The system architecture is based on technical modules used in cardiovascular implants in order to minimize legal certification efforts for its perspective usage in medical applications. The sensor chip operates via the principle of affinity viscometry, which is realized by a fully embedded biomedical microelectromechanical systems (BioMEMS prepared in 0.25-µm complementary metal–oxide–semiconductor (CMOS/BiCMOS technology. Communication with a base station is established in the 402–405 MHz band used for medical implant communication services (MICS. The implant shall operate within the interstitial tissue, and the hermetical sealing of the electronic system against interaction with the body fluid is established using titanium housing. Only the sensor chip and the antenna are encapsulated in an epoxy header closely connected to the metallic housing. The study demonstrates that biosensor implants for the sensing of low-molecular-weight metabolites in the interstitial may successfully rely on components already established in cardiovascular implantology.

  20. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Directory of Open Access Journals (Sweden)

    Chin-Sheng Tang

    Full Text Available To prevent surgical site infection (SSI, the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH, and carbon dioxide (CO2, suspended particulate matter (PM, and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18% and traumatic surgery room (8%. The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  1. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Science.gov (United States)

    Tang, Chin-Sheng; Wan, Gwo-Hwa

    2013-01-01

    To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  2. Development of a National Consensus for Tactical Emergency Medical Support (TEMS) Training Programs--Operators and Medical Providers.

    Science.gov (United States)

    Schwartz, Richard; Lerner, Brooke; Llwewllyn, Craig; Pennardt, Andre; Wedmore, Ian; Callaway, David; Wightman, John; Casillas, Raymond; Eastman, Alex; Gerold, Kevin; Giebner, Stephen; Davidson, Robert; Kamin, Richard; Piazza, Gina; Bollard, Glenn; Carmona, Phillip; Sonstrom, Ben; Seifarth, William; Nicely, Barbara; Croushorn, John; Carmona, Richard

    2014-01-01

    Tactical teams are at high risk of sustaining injuries. Caring for these casualties in the field involves unique requirements beyond what is provided by traditional civilian emergency medical services (EMS) systems. Despite this need, the training objectives and competencies are not uniformly agreed to or taught. An expert panel was convened that included members from the Departments of Defense, Homeland Security, Justice, and Health and Human Services, as well as federal, state, and local law-enforcement officers who were recruited through requests to stakeholder agencies and open invitations to individuals involved in Tactical Emergency Medical Services (TEMS) or its oversight. Two face-to-face meetings took place. Using a modified Delphi technique, previously published TEMS competencies were reviewed and updated. The original 17 competency domains were modified and the most significant changes were the addition of Tactical Emergency Casualty Care (TECC), Tactical Familiarization, Legal Aspects of TEMS, and Mass Casualty Triage to the competency domains. Additionally, enabling and terminal learning objectives were developed for each competency domain. This project has developed a minimum set of medical competencies and learning objectives for both tactical medical providers and operators. This work should serve as a platform for ensuring minimum knowledge among providers, which will serve enhance team interoperability and improve the health and safety of tactical teams and the public. 2014.

  3. Production of platinum radioisotopes at Brookhaven Linac Isotope Producer (BLIP

    Directory of Open Access Journals (Sweden)

    Smith Suzanne V.

    2017-01-01

    Full Text Available The accelerator production of platinum isotopes was investigated at the Brookhaven Linac Isotope Producer (BLIP. In this study high purity natural platinum foils were irradiated at 53.2, 65.7, 105.2, 151.9, 162.9 and 173.3.MeV. The irradiated foils were digested in aqua regia and then converted to their hydrochloride salt with concentrated hydrochloric acid before analyzing by gamma spectrometry periodically for at least 10 days post end of bombardment. A wide range of platinum (Pt, gold (Au and iridium (Ir isotopes were identified. Effective cross sections at BLIP for Pt-188, Pt-189, Pt-191 and Pt-195m were compared to literature and theoretical cross sections determined using Empire-3.2. The majority of the effective cross sections (<70 MeV confirm those reported in the literature. While the absolute values of the theoretical cross sections were up to a factor of 3 lower, Empire 3.2 modeled thresholds and maxima correlated well with experimental values. Preliminary evaluation into a rapid separation of Pt isotopes from high levels of Ir and Au isotopes proved to be a promising approach for large scale production. In conclusion, this study demonstrated that with the use of isotopically enriched target material accelerator production of selected platinum isotopes is feasible over a wide proton energy range.

  4. A Review of Supplementary Medical Aspects of Post-Cold War UN Peacekeeping Operations: Trends, Lessons Learned, Courses of Action, and Recommendations.

    Science.gov (United States)

    Johnson, Ralph J

    2015-01-01

    Post-Cold War United Nations Peace Keeping Operations (UN PKOs) have been increasingly involved in dangerous areas with ill-defined boundaries, harsh and remote geographies, simmering internecine armed conflict, and disregard on the part of some local parties for peacekeepers' security and role. In the interest of force protection and optimizing operations, a key component of UN PKOs is healthcare and medical treatment. The expectation is that UN PKO medical support will adjust to the general intent and structure of UN PKOs. To do so requires effective policies and planning informed by a review of all medical aspects of UN PKO operations, including those considered supplementary, that is, less crucial but contributing nonetheless. Medical aspects considered paramount and key to UN PKOs have received relatively thorough treatment elsewhere. The intent of this article is to report on ancillary and supplemental medical aspects practical to post-Cold War UN PKO operations assembled through an iterative inquiry of open-source articles. Recommendations are made about possible courses of action in terms of addressing trends found in such medical aspects of PKOs and relevance of US/NATO/European Union models and research.

  5. Risk assessment and optimization (ALARA) analysis for the environmental remediation of Brookhaven National Laboratory's hazardous waste management facility

    International Nuclear Information System (INIS)

    Dionne, B.J.; Morris, S. III; Baum, J.W.

    1998-03-01

    The Department of Energy's (DOE) Office of Environment, Safety, and Health (EH) sought examples of risk-based approaches to environmental restoration to include in their guidance for DOE nuclear facilities. Extensive measurements of radiological contamination in soil and ground water have been made at Brookhaven National Laboratory's Hazardous Waste Management Facility (HWMF) as part of a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) remediation process. This provided an ideal opportunity for a case study. This report provides a risk assessment and an open-quotes As Low as Reasonably Achievableclose quotes (ALARA) analysis for use at other DOE nuclear facilities as an example of a risk-based decision technique

  6. Neutrino oscillation study in the muon neutrino → electron neutrino channel at the Brookhaven accelerator

    International Nuclear Information System (INIS)

    Astier, P.

    1987-09-01

    The E816 experiment described in this thesis is devoted to a neutrino oscillation search at the Brookhaven AGS. The method used here is to look with a fine grained calorimeter for the appearence of electron neutrino in a muon neutrino beam. After recalling the theoretical treatment of the neutrino mass problem, the experimental phenomenology of massive neutrinos and more specifically neutrino oscillations is reviewed. The experiment itself is then extensively described, both on the technical side (detector, beam, simulation) and on the analysis side. In particular the statistical separation of the electromagnetic showers from electrons - our signal - and from photons - our background - treated in detail. The present analysis is based on 2/3 of the final statistics and it leads to the - preliminary - observation of an electron excess in the neutrino interactions yielding 19 ± 15.6 (stat) ± 7 (syst) [fr

  7. The Establishment and operation of Longjing Medical College - The History of Longjing Medical College as Frontier History: Focusing on its ‘Disconnection’ and ‘Continuity’ -

    Directory of Open Access Journals (Sweden)

    Mira MOON

    2017-08-01

    Full Text Available Longjing Medial College, established in Longjing, Yanbian, China on September 12, 1945, existed for about 1 year and 6 months until it was renamed as the Medical Department of Dongbei Junzheng Daxue Jilin Fenxiao in April 1947. However, there are only few records and studies on Longjing Medical College in Yanbian as well as in Korea. In order to fill the gap, this study attempted to restore the history of Longjing Medical College built in Yanbian, China immediately after the liberation. In particular, it analyzed how and why the Longjing Medical College was founded and operated, and which relations the college had with the post-war medical educational institutions, focusing on the ‘disconnection’ and ‘continuity’ in the historical sense. Since the establishment of Manchukuo, the Japanese colonial government had made it a major “frontier” and actively promoted the mass migration of Japanese and Koreans. For them, the government also set up three Exploitation Medical Schools in 1940. As a part of these three institutions, Longjing Exploitation Medical School educated more than 150 students by 1945, of which about one third was Korean. After the liberation, the Longjing Educational Alliance decided to pursue the return-movement of the Longjing Exploitation Medical School and took over the institution. On September 12, 1945, Longjing Medical College opened at the school site of Longjing Exploitation Medical School. Longjing Medical College was founded by people who had ‘the perspective of Korean nationality’ in an atmosphere where the ‘ethnicity’ of the Koreans exercised considerable power. Nevertheless, in 1946, when the Chinese Civil War began and the Yanbian region became an important base of the Chinese Communist Party, the Party began to expand and strengthen their influences in the region. Accordingly, the operation rights of Longjing Medical College were transferred to the Yanbian Administrative offices of Supervision and

  8. Brookhaven National Laboratory 2008 Site Environment Report Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Brookhaven National Laboratory

    2009-10-01

    Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of the Laboratory's environmental performance during the calendar year in review. Volume I of the SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and performance in restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. Volume II of the SER, the Groundwater Status Report, also is prepared annually to report on the status of and evaluate the performance of groundwater treatment systems at the Laboratory. Volume II includes detailed technical summaries of groundwater data and its interpretation, and is intended for internal BNL users, regulators, and other technically oriented stakeholders. A brief summary of the information contained in Volume II is included in this volume in Chapter 7, Groundwater Protection. Both reports are available in print and as downloadable files on the BNL web page at http://www.bnl.gov/ewms/ser/. An electronic version on compact disc is distributed with each printed report. In addition, a summary of Volume I is prepared each year to provide a general overview of the report, and is distributed with a compact disc containing the full report.

  9. Concepts and techniques: Active electronics and computers in safety-critical accelerator operation

    International Nuclear Information System (INIS)

    Frankel, R.S.

    1995-01-01

    The Relativistic Heavy Ion Collider (RHIC) under construction at Brookhaven National Laboratory, requires an extensive Access Control System to protect personnel from Radiation, Oxygen Deficiency and Electrical hazards. In addition, the complicated nature of operation of the Collider as part of a complex of other Accelerators necessitates the use of active electronic measurement circuitry to ensure compliance with established Operational Safety Limits. Solutions were devised which permit the use of modern computer and interconnections technology for Safety-Critical applications, while preserving and enhancing, tried and proven protection methods. In addition a set of Guidelines, regarding required performance for Accelerator Safety Systems and a Handbook of design criteria and rules were developed to assist future system designers and to provide a framework for internal review and regulation

  10. Concepts and techniques: Active electronics and computers in safety-critical accelerator operation

    Energy Technology Data Exchange (ETDEWEB)

    Frankel, R.S.

    1995-12-31

    The Relativistic Heavy Ion Collider (RHIC) under construction at Brookhaven National Laboratory, requires an extensive Access Control System to protect personnel from Radiation, Oxygen Deficiency and Electrical hazards. In addition, the complicated nature of operation of the Collider as part of a complex of other Accelerators necessitates the use of active electronic measurement circuitry to ensure compliance with established Operational Safety Limits. Solutions were devised which permit the use of modern computer and interconnections technology for Safety-Critical applications, while preserving and enhancing, tried and proven protection methods. In addition a set of Guidelines, regarding required performance for Accelerator Safety Systems and a Handbook of design criteria and rules were developed to assist future system designers and to provide a framework for internal review and regulation.

  11. IEEE 1394 CAMERA IMAGING SYSTEM FOR BROOKHAVENS BOOSTER APPLICATION FACILITY BEAM DIAGNOSTICS

    International Nuclear Information System (INIS)

    BROWN, K.A.; FRAK, B.; GASSNER, D.; HOFF, L.; OLSEN, R.H.; SATOGATA, T.; TEPIKIAN, S.

    2002-01-01

    Brookhaven's Booster Applications Facility (BAF) will deliver resonant extracted heavy ion beams from the AGS Booster to short-exposure fixed-target experiments located at the end of the BAF beam line. The facility is designed to deliver a wide range of heavy ion species over a range of intensities from 10 3 to over 10 8 ions/pulse, and over a range of energies from 0.1 to 3.0 GeV/nucleon. With these constraints we have designed instrumentation packages which can deliver the maximum amount of dynamic range at a reasonable cost. Through the use of high quality optics systems and neutral density light filters we will achieve 4 to 5 orders of magnitude in light collection. By using digital IEEE1394 camera systems we are able to eliminate the frame-grabber stage in processing and directly transfer data at maximum rates of 400 Mb/set. In this note we give a detailed description of the system design and discuss the parameters used to develop the system specifications. We will also discuss the IEEE1394 camera software interface and the high-level user interface

  12. Medical status of Marshallese accidentally exposed to 1954 Bravo fallout radiation, January 1983-December 1984

    International Nuclear Information System (INIS)

    Adams, W.H.; Engle, J.R.; Harper, J.A.; Heotis, P.M.; Scott, W.A.

    1986-01-01

    March 1, 1984, was the 30th anniversary of the Bravo thermonuclear test that resulted in the accidental exposure of the populations of Rongelap and Utirik atolls to radioactive fallout. The chronicling of the medical events resulting from that exposure is continued in this report, which covers the period from January 1983 through December 1984. An updated listing of all relevant publications from the Medical Department Brookhaven National Laboratory, is presented in the Reference Section. Thirty years of observation continue to show no detectable increase in mortality in the exposed population as a result of that exposure. The survival curves of the high-exposure Rongelap group, the low-exposure Utirik population, and an unexposed group of Rongelap people matched by age and sex to the exposed Rongelap group in 1957 continue to be similar. 89 refs., 2 figs., 6 tabs

  13. Medical status of Marshallese accidentally exposed to 1954 Bravo fallout radiation, January 1983-December 1984

    Energy Technology Data Exchange (ETDEWEB)

    Adams, W.H.; Engle, J.R.; Harper, J.A.; Heotis, P.M.; Scott, W.A.

    1986-01-01

    March 1, 1984, was the 30th anniversary of the Bravo thermonuclear test that resulted in the accidental exposure of the populations of Rongelap and Utirik atolls to radioactive fallout. The chronicling of the medical events resulting from that exposure is continued in this report, which covers the period from January 1983 through December 1984. An updated listing of all relevant publications from the Medical Department Brookhaven National Laboratory, is presented in the Reference Section. Thirty years of observation continue to show no detectable increase in mortality in the exposed population as a result of that exposure. The survival curves of the high-exposure Rongelap group, the low-exposure Utirik population, and an unexposed group of Rongelap people matched by age and sex to the exposed Rongelap group in 1957 continue to be similar. 89 refs., 2 figs., 6 tabs.

  14. 50 Years of the Radiological Research Accelerator Facility (RARAF)

    OpenAIRE

    Marino, Stephen A.

    2017-01-01

    The Radiological Research Accelerator Facility (RARAF) is in its 50th year of operation. It was commissioned on April 1, 1967 as a collaboration between the Radiological Research Laboratory (RRL) of Columbia University, and members of the Medical Research Center of Brookhaven National Laboratory (BNL). It was initially funded as a user facility for radiobiology and radiological physics, concentrating on monoenergetic neutrons. Facilities for irradiation with MeV light charged particles were d...

  15. DECOMMISSIONING THE BROOKHAVEN NATIONAL LABORATORY BUILDING 830 GAMMA IRRADIATION FACILITY.

    Energy Technology Data Exchange (ETDEWEB)

    BOWERMAN, B.S.; SULLIVAN, P.T.

    2001-08-13

    The Building 830 Gamma Irradiation Facility (GIF) at Brookhaven National Laboratory (BNL) was decommissioned because its design was not in compliance with current hazardous tank standards and its cobalt-60 sources were approaching the end of their useful life. The facility contained 354 stainless steel encapsulated cobalt-60 sources in a pool, which provided shielding. Total cobalt-60 inventory amounted to 24,000 Curies when the sources were shipped for disposal. The decommissioning project included packaging, transport, and disposal of the sources and dismantling and disposing of all other equipment associated with the facility. Worker exposure was a major concern in planning for the packaging and disposal of the sources. These activities were planned carefully according to ALARA (As Low As Reasonably Achievable) principles. As a result, the actual occupational exposures experienced during the work were within the planned levels. Disposal of the pool water required addressing environmental concerns, since the planned method was to discharge the slightly contaminated water to the BNL sewage treatment plant. After the BNL evaluation procedure for discharge to the sewage treatment plant was revised and reviewed by regulators and BNL's Community Advisory Council, the pool water was discharged to the Building 830 sanitary system. Because the sources were sealed and the pool water contamination levels were low, most of the remaining equipment was not contaminated; therefore disposal was straightforward, as scrap metal and construction debris.

  16. Risk assessment and optimization (ALARA) analysis for the environmental remediation of Brookhaven National Laboratory's hazardous waste management facility

    International Nuclear Information System (INIS)

    Dionne, B.J.; Morris, S.C. III; Baum, J.W.

    1998-01-01

    The Department of Energy's (DOE) Office of Environment, Safety, and Health (EH) sought examples of risk-based approaches to environmental restoration to include in their guidance for DOE nuclear facilities. Extensive measurements of radiological contamination in soil and ground water have been made at Brookhaven National Laboratory's Hazardous Waste Management Facility (HWMF) as part of a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) remediation process. This provided an ideal opportunity for a case study. This report provides a risk assessment and an open-quotes As Low as Reasonably Achievableclose quotes (ALARA) analysis for use at other DOE nuclear facilities as an example of a risk-based decision technique. This document contains the Appendices for the report

  17. Review of the {sup 60}Co Source. Development Program at Brookhaven National Laboratory; Le Programme de Mise au Point des Sources au {sup 60}Co au Laboratoire National de Brookhaven; Obzor programmy po razrabotke istochnikov {sup 60}Co v brukkhejvenskoj natsional'noj laboratorii; El Programa de Preparacion de Fuentes de {sup 60}Co del Laboratorio Nacional de Brookhaven

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, O. A. [Brookhaven National Laboratory, Upton, NY (United States)

    1966-11-15

    Early in the 1950's, at the request of the United States Atomic Energy Commission, Brookhaven National Laboratory (BNL) undertook the development of radiation sources. These sources were mainly of two types: large tubes, and flat strips. Initially these were used for research at BNL. Later, other institutions were permitted to use the irradiation facilities designed for these sources. As interest grew, source-irradiator combinations were made available to other researchers. Shipping containers for sources were developed. Small hot cells and water-filled pools were constructed to utilize the sources. Methods of dosimetry, curie evaluation, and irradiator design for these sources are discussed in this paper. During the research stages, economics were not usually important; however, the trend toward large- scale radiation processing in the field of food, chemicals and medical supplies will require careful consideration of the technical and economic aspects of source design. The development of the BNL Standard Mark I and Mark II Sources, already in use in a number of' facilities, is to satisfy these important requirements. The Mark I and Mark II sources are interchangeable. An improvement in the Mark II element design is that the inner cladding is metallurgically bonded to the cobalt core. It is now possible, for the first time, to reactivate these source elements after a period of use. Individual strips are sized for easy arrangement in plaques of various dimensions and shapes. The design philosophy, fabrication techniques, and test procedures, together with source analysis and curie evaluation, are described. Comparisons are made with other source types currently in use and economical and technical advantages are discussed. (author) [French] A la demande de la Commission de l'energie atomique des Etats-Unis, le Laboratoire national de Brookhaven a entrepris des les annees 50 la mise au point de sources de rayonnement. Ces sources etaient principalement de deux types

  18. Multi-MW accelerator target material properties under proton irradiation at Brookhaven National Laboratory linear isotope producer

    Science.gov (United States)

    Simos, N.; Ludewig, H.; Kirk, H.; Dooryhee, E.; Ghose, S.; Zhong, Z.; Zhong, H.; Makimura, S.; Yoshimura, K.; Bennett, J. R. J.; Kotsinas, G.; Kotsina, Z.; McDonald, K. T.

    2018-05-01

    The effects of proton beams irradiating materials considered for targets in high-power accelerator experiments have been studied using the Brookhaven National Laboratory's (BNL) 200 MeV proton linac. A wide array of materials and alloys covering a wide range of the atomic number (Z) are being scoped by the high-power accelerator community prompting the BNL studies to focus on materials representing each distinct range, i.e. low-Z, mid-Z and high-Z. The low range includes materials such as beryllium and graphite, the midrange alloys such as Ti-6Al-4V, gum metal and super-Invar and finally the high-Z range pure tungsten and tantalum. Of interest in assessing proton irradiation effects are (a) changes in physiomechanical properties which are important in maintaining high-power target functionality, (b) identification of possible limits of proton flux or fluence above which certain materials cease to maintain integrity, (c) the role of material operating temperature in inducing or maintaining radiation damage reversal, and (d) phase stability and microstructural changes. The paper presents excerpt results deduced from macroscopic and microscopic post-irradiation evaluation (PIE) following several irradiation campaigns conducted at the BNL 200 MeV linac and specifically at the isotope producer beam-line/target station. The microscopic PIE relied on high energy x-ray diffraction at the BNL NSLS X17B1 and NSLS II XPD beam lines. The studies reveal the dramatic effects of irradiation on phase stability in several of the materials, changes in physical properties and ductility loss as well as thermally induced radiation damage reversal in graphite and alloys such as super-Invar.

  19. Proposed ultraviolet free-electron laser at Brookhaven National Laboratory: A source for time-resolved biochemical spectroscopy

    International Nuclear Information System (INIS)

    Johnson, E.D.; Sutherland, J.C.; Laws, W.R.

    1992-01-01

    Brookhaven National Laboratory is designing an ultraviolet free- electron laser (UV-FEL) user facility that will provide pico-second and sub-picosecond pulses of coherent ultraviolet radiation for wavelengths from 300 to 75 nm. Pulse width will be variable from abut 7 ps to ∼ 200 fs, with repetition rates as high as 10 4 Hz, single pulse energies > 1 mJ and hence peak pulse power >200 MW and average beam power > 10 W. The facility will be capable of ''pump-probe'' experiments utilizing the FEL radiation with: (1) synchronized auxiliary lasers, (2) a second, independently tunable FEL beam, or (3) broad-spectrum, high-intensity x-rays from the adjacent National Synchrotron Light Source. The UV-FEL consists of a high repetition rate recirculating superconducting linear accelerator which feeds pulses of electrons to two magnetic wigglers. Within these two devices, photons from tunable ''conventional'' laser would be frequency multiplied and amplified. By synchronously tuning the seed laser and modulating the energy of the electron beam, tuning of as much as 60% in wavelength is possible between alternating pulses supplied to different experimental stations, with Fourier transform limited resolution. Thus, up to four independent experiments may operate at one time, each with independent control of the wavelength and pulse duration. The UV-FEL will make possible new avenues of inquiry in time studies of diverse field including chemical, surface, and solid state physics, biology and materials science. The experimental area is scheduled to include a station dedicated to biological research. The complement of experimental and support facilities required by the biology station will be determined by the interests of the user community. 7 refs., 5 figs

  20. Concept of Operations Evaluation for Mitigating Space Flight-Relevant Medical Issues in a Planetary Habitat

    Science.gov (United States)

    Barsten, Kristina; Hurst, Victor, IV; Scheuring, Richard; Baumann, David K.; Johnson-Throop, Kathy

    2010-01-01

    Introduction: Analogue environments assist the NASA Human Research Program (HRP) in developing capabilities to mitigate high risk issues to crew health and performance for space exploration. The Habitat Demonstration Unit (HDU) is an analogue habitat used to assess space-related products for planetary missions. The Exploration Medical Capability (ExMC) element at the NASA Johnson Space Center (JSC) was tasked with developing planetary-relevant medical scenarios to evaluate the concept of operations for mitigating medical issues in such an environment. Methods: Two medical scenarios were conducted within the simulated planetary habitat with the crew executing two space flight-relevant procedures: Eye Examination with a corneal injury and Skin Laceration. Remote guidance for the crew was provided by a flight surgeon (FS) stationed at a console outside of the habitat. Audio and video data were collected to capture the communication between the crew and the FS, as well as the movements of the crew executing the procedures. Questionnaire data regarding procedure content and remote guidance performance also were collected from the crew immediately after the sessions. Results: Preliminary review of the audio, video, and questionnaire data from the two scenarios conducted within the HDU indicate that remote guidance techniques from an FS on console can help crew members within a planetary habitat mitigate planetary-relevant medical issues. The content and format of the procedures were considered concise and intuitive, respectively. Discussion: Overall, the preliminary data from the evaluation suggest that use of remote guidance techniques by a FS can help HDU crew execute space exploration-relevant medical procedures within a habitat relevant to planetary missions, however further evaluations will be needed to implement this strategy into the complete concept of operations for conducting general space medicine within similar environments

  1. Performance Support Tools for Space Medical Operations

    Science.gov (United States)

    Byrne, Vicky E.; Schmidt, Josef; Barshi, Immanuel

    2009-01-01

    The early Constellation space missions are expected to have medical capabilities very similar to those currently on the Space Shuttle and International Space Station (ISS). For Crew Exploration Vehicle (CEV) missions to ISS, medical equipment will be located on ISS, and carried into CEV in the event of an emergency. Flight Surgeons (FS) on the ground in Mission Control will be expected to direct the Crew Medical Officer (CMO) during medical situations. If there is a loss of signal and the crew is unable to communicate with the ground, a CMO would be expected to carry out medical procedures without the aid of a FS. In these situations, performance support tools can be used to reduce errors and time to perform emergency medical tasks. Human factors personnel at Johnson Space Center have recently investigated medical performance support tools for CMOs on-orbit, and FSs on the ground. This area of research involved the feasibility of Just-in-time (JIT) training techniques and concepts for real-time medical procedures. In Phase 1, preliminary feasibility data was gathered for two types of prototype display technologies: a hand-held PDA, and a Head Mounted Display (HMD). The PDA and HMD were compared while performing a simulated medical procedure using ISS flight-like medical equipment. Based on the outcome of Phase 1, including data on user preferences, further testing was completed using the PDA only. Phase 2 explored a wrist-mounted PDA, and compared it to a paper cue card. For each phase, time to complete procedures, errors, and user satisfaction were captured. Information needed by the FS during ISS mission support, especially for an emergency situation (e.g. fire onboard ISS), may be located in many different places around the FS s console. A performance support tool prototype is being developed to address this issue by bringing all of the relevant information together in one place. The tool is designed to include procedures and other information needed by a FS

  2. A new high resolution neutron powder diffractometer at the Brookhaven high flux beam reactor

    International Nuclear Information System (INIS)

    Passell, L.; Bar-Ziv, S.; Gardner, D.W.; Cox, D.E.; Axe, J.D.

    1991-01-01

    A high resolution neutron powder diffractometer under construction at the Brookhaven HFBR is expected to be completed by mid-1991. The new machine will have a Ge (511) monochromator with a take-off angle of 120 o (λ=1.89A) and 64 3 He counters in the detector bank. There will be interchangeable collimators before the monochromator allowing a choice of 5 or 11' horizontal divergence, and 10 cm-high, 5' collimators in front of the detectors. In the higher resolution mode, Δd/d is expected to be about 6x10 -4 at the resolution minimum. The diffractometer is generally similar to D2B at the Institut Laue-Langevin except for the monochromator. This will consist of a vertically focussing array of segments 3x1.27 cm in dimensions cut from stacks of 20 0.43 mm wafers that have been pressed and brazed together. Preliminary measurements indicate that a mosaic width of 0.1-0.15 o and a peak reflectivity of 25% can be achieved in this way. (author) 2 figs., 22 refs

  3. Risk assessment and optimization (ALARA) analysis for the environmental remediation of Brookhaven National Laboratory`s hazardous waste management facility

    Energy Technology Data Exchange (ETDEWEB)

    Dionne, B.J.; Morris, S. III; Baum, J.W. [and others

    1998-03-01

    The Department of Energy`s (DOE) Office of Environment, Safety, and Health (EH) sought examples of risk-based approaches to environmental restoration to include in their guidance for DOE nuclear facilities. Extensive measurements of radiological contamination in soil and ground water have been made at Brookhaven National Laboratory`s Hazardous Waste Management Facility (HWMF) as part of a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) remediation process. This provided an ideal opportunity for a case study. This report provides a risk assessment and an {open_quotes}As Low as Reasonably Achievable{close_quotes} (ALARA) analysis for use at other DOE nuclear facilities as an example of a risk-based decision technique.

  4. Deployment of Smart 3D Subsurface Contaminant Characterization at the Brookhaven Graphite Research Reactor

    International Nuclear Information System (INIS)

    Sullivan, T.; Heiser, J.; Kalb, P.; Milian, L.; Newson, C.; Lilimpakas, M.; Daniels, T.

    2002-01-01

    The Brookhaven Graphite Research Reactor (BGRR) Historical Site Assessment (BNL 1999) identified contamination inside the Below Grade Ducts (BGD) resulting from the deposition of fission and activation products from the pile on the inner carbon steel liner during reactor operations. Due to partial flooding of the BGD since shutdown, some of this contamination may have leaked out of the ducts into the surrounding soils. The baseline remediation plan for cleanup of contaminated soils beneath the BGD involves complete removal of the ducts, followed by surveying the underlying and surrounding soils, then removing soil that has been contaminated above cleanup goals. Alternatively, if soil contamination around and beneath the BGD is either non-existent/minimal (below cleanup goals) or is very localized and can be ''surgically removed'' at a reasonable cost, the BGD can be decontaminated and left in place. The focus of this Department of Energy Accelerated Site Technology Deployment (DOE ASTD) project was to determine the extent (location, type, and level) of soil contamination surrounding the BGD and to present this data to the stakeholders as part of the Engineering Evaluation/Cost Analysis (EE/CA) process. A suite of innovative characterization tools was used to complete the characterization of the soil surrounding the BGD in a cost-effective and timely fashion and in a manner acceptable to the stakeholders. The tools consisted of a tracer gas leak detection system that was used to define the gaseous leak paths out of the BGD and guide soil characterization studies, a small-footprint Geoprobe to reach areas surrounding the BGD that were difficult to access, two novel, field-deployed, radiological analysis systems (ISOCS and BetaScint) and a three-dimensional (3D) visualization system to facilitate data analysis/interpretation. All of the technologies performed as well or better than expected and the characterization could not have been completed in the same time or at

  5. Biological applications of ultraviolet free-electron lasers

    International Nuclear Information System (INIS)

    Sutherland, J.C.

    1997-10-01

    This review examines the possibilities for biological research using the three ultraviolet free-electron lasers that are nearing operational status in the US. The projected operating characteristics of major interest in biological research of the free-electron lasers at Brookhaven National Laboratory, the Thomas Jefferson National Accelerator Facility, and Duke University are presented. Experimental applications in the areas of far- and vacuum ultraviolet photophysics and photochemistry, structural biology, environmental photobiology, and medical research are discussed and the prospects for advances in these areas, based upon the characteristics of the new ultraviolet free-electron lasers, are evaluated

  6. MEDIC: medical embedded device for individualized care.

    Science.gov (United States)

    Wu, Winston H; Bui, Alex A T; Batalin, Maxim A; Au, Lawrence K; Binney, Jonathan D; Kaiser, William J

    2008-02-01

    Presented work highlights the development and initial validation of a medical embedded device for individualized care (MEDIC), which is based on a novel software architecture, enabling sensor management and disease prediction capabilities, and commercially available microelectronic components, sensors and conventional personal digital assistant (PDA) (or a cell phone). In this paper, we present a general architecture for a wearable sensor system that can be customized to an individual patient's needs. This architecture is based on embedded artificial intelligence that permits autonomous operation, sensor management and inference, and may be applied to a general purpose wearable medical diagnostics. A prototype of the system has been developed based on a standard PDA and wireless sensor nodes equipped with commercially available Bluetooth radio components, permitting real-time streaming of high-bandwidth data from various physiological and contextual sensors. We also present the results of abnormal gait diagnosis using the complete system from our evaluation, and illustrate how the wearable system and its operation can be remotely configured and managed by either enterprise systems or medical personnel at centralized locations. By using commercially available hardware components and software architecture presented in this paper, the MEDIC system can be rapidly configured, providing medical researchers with broadband sensor data from remote patients and platform access to best adapt operation for diagnostic operation objectives.

  7. Quantification of operator actions during ATWS following MSIV closure

    International Nuclear Information System (INIS)

    Luckas, W.J. Jr.; O'Brien, J.N.; Perline, R.K.; Spettell, C.M.

    1986-01-01

    Brookhaven National Laboratory (BNL) assisted the Accident Sequence Evaluation Program (ASEP) by performing a Human Reliability Analysis (HRA) of the operations crew tasks during the Anticipated Transient Without Scram (ATWS) accident sequence with Main Steam Isolation Valve (MSIV) closure at the Peach Bottom Atomic Power Station, Unit 2. A detailed task analysis was performed based on consideration of staffing, team interaction, and control room layout at Peach Bottom. ATWS scenarios developed by Oak Ridge National Laboratory (ORNL) and Idaho National Engineering Laboratory (INEL) were reviewed. Discussions were held with thermal-hydrodynamic/core neutronics engineers at BNL to determine the success criterion for tasks. Five major operator tasks were identified. After reviewing a computerized data base of human error probabilities (HEPs) from 19 probabilistic risk assessments (PRAs) for tasks similar to those above to establish the historic range of HEPs for such errors, consensus opinion and structured expert judgment was used to quantify each of these tasks at each branch point in the event tree within that range

  8. The lifesaving potential of specialized on-scene medical support for urban tactical operations.

    Science.gov (United States)

    Metzger, Jeffery C; Eastman, Alexander L; Benitez, Fernando L; Pepe, Paul E

    2009-01-01

    Since the 1980s, the specialized field of tactical medicine has evolved with growing support from numerous law-enforcement and medical organizations. On-scene backup from tactical emergency medical support (TEMS) providers has not only permitted more immediate advanced medical aid to injured officers, victims, bystanders, and suspects, but also allows for rapid after-incident medical screening or minor treatments that can obviate an unnecessary transport to an emergency department. The purpose of this report is to document one very explicit benefit of TEMS deployment, namely, a situation in which a police officer's life was saved by the routine on-scene presence of specialized TEMS physicians. In this specific case, a police officer was shot in the anterior neck during a law-enforcement operation and became moribund with massive hemorrhage and compromised airway. Two TEMS physicians, who had been integrated into the tactical law-enforcement team, were on scene, controlled the hemorrhage, and provided a surgical airway. By the time of arrival at the hospital, the patient had begun purposeful movements and, within 12 hours, was alert and oriented. Considering the rapid decline in the patient's condition, it was later deemed by quality assurance reviewers that the on-scene presence of these TEMS providers was lifesaving.

  9. Statistical analysis of operating efficiency and failures of a medical linear accelerator for ten years

    International Nuclear Information System (INIS)

    Ju, Sang Gyu; Huh, Seung Jae; Han, Young Yih

    2005-01-01

    To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2100C over a ten year period were retrospectively analyzed. The failures were classified according to the involved functional subunits, with each class rated into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for 20% of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and 83% of the expected values, respectively. The operating efficiency was maintained at 95% or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. More rigorous equipment maintenance is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the quality of patient treatment

  10. Risk analysis of releases from accidents during mid-loop operation at Surry

    International Nuclear Information System (INIS)

    Jo, J.; Lin, C.C.; Nimnual, S.; Mubayi, V.; Neymotin, L.

    1992-11-01

    Studies and operating experience suggest that the risk of severe accidents during low power operation and/or shutdown (LP/S) conditions could be a significant fraction of the risk at full power operation. Two studies have begun at the Nuclear Regulatory Commission (NRC) to evaluate the severe accident progression from a risk perspective during these conditions: One at the Brookhaven National Laboratory for the Surry plant, a pressurized water reactor (PWR), and the other at the Sandia National Laboratories for the Grand Gulf plant, a boiling water reactor (BWR). Each of the studies consists of three linked, but distinct, components: a Level I probabilistic risk analysis (PRA) of the initiating events, systems analysis, and accident sequences leading to core damage; a Level 2/3 analysis of accident progression, fuel damage, releases, containment performance, source term and consequences-off-site and on-site; and a detailed Human Reliability Analysis (HRA) of actions relevant to plant conditions during LP/S operations. This paper summarizes the approach taken for the Level 2/3 analysis at Surry and provides preliminary results on the risk of releases and consequences for one plant operating state, mid-loop operation, during shutdown

  11. [Discussion on Quality Evaluation Method of Medical Device During Life-Cycle in Operation Based on the Analytic Hierarchy Process].

    Science.gov (United States)

    Zheng, Caixian; Zheng, Kun; Shen, Yunming; Wu, Yunyun

    2016-01-01

    The content related to the quality during life-cycle in operation of medical device includes daily use, repair volume, preventive maintenance, quality control and adverse event monitoring. In view of this, the article aims at discussion on the quality evaluation method of medical devices during their life cycle in operation based on the Analytic Hierarchy Process (AHP). The presented method is proved to be effective by evaluating patient monitors as example. The method presented in can promote and guide the device quality control work, and it can provide valuable inputs to decisions about purchase of new device.

  12. Optimization of AGS Polarized Proton Operation with the Warm Helical Snake

    CERN Document Server

    Takano, Junpei; Bai, Mei; Brown, Kevin A; Gardner, Chris J; Glenn, Joseph; Hattori, Toshiyuki; Huang, Haixin; Luccio, Alfredo U; MacKay, William W; Okamura, Masahiro; Roser, Thomas; Tepikian, Steven; Tsoupas, Nicholaos

    2005-01-01

    A normal conducting helical dipole partial Siberian snake (Warm Snake) has been installed in the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory (BNL) for overcoming all of imperfection depolarizing resonances and reducing the transverse coupling resonances caused by the solenoidal Siberian snake which had been operated in AGS before the last polarized run. The polarized proton beam has been accelerated successfully with the warm snake and the polarization at extraction of the AGS was increased to 50% as opposed to 40% with the solenoidal snake. The magnetic field and beam trajectory in the warm snake was calculated by using the OPERA-3D/TOSCA software. We present optimization of the warm snake with beam during RUN5.

  13. Risk assessment and optimization (ALARA) analysis for the environmental remediation of Brookhaven National Laboratory`s hazardous waste management facility

    Energy Technology Data Exchange (ETDEWEB)

    Dionne, B.J.; Morris, S.C. III; Baum, J.W. [and others

    1998-01-01

    The Department of Energy`s (DOE) Office of Environment, Safety, and Health (EH) sought examples of risk-based approaches to environmental restoration to include in their guidance for DOE nuclear facilities. Extensive measurements of radiological contamination in soil and ground water have been made at Brookhaven National Laboratory`s Hazardous Waste Management Facility (HWMF) as part of a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) remediation process. This provided an ideal opportunity for a case study. This report provides a risk assessment and an {open_quotes}As Low as Reasonably Achievable{close_quotes} (ALARA) analysis for use at other DOE nuclear facilities as an example of a risk-based decision technique. This document contains the Appendices for the report.

  14. Review of medical findings in a Marshallese population twenty-six years after accidental exposure to radioactive fallout

    International Nuclear Information System (INIS)

    Conard, R.A.; Paglia, D.E.; Larsen, P.R.

    1980-01-01

    In March 1954, radioactive debris from a thermonuclear weapon test at Bikini Atoll deviated from predicted trajectories and contaminated several atolls in the northern Marshall Islands. As a result, 239 native inhabitants of these islands along with 28 American servicemen and 23 Japanese fishermen received variably severe exposures to diverse ionizing radiations. Fallout material consisted largely of mixed fission products with small amounts of neutron-induced radionuclides and minimal amounts of fissionable elements, producing a complex spectrum of electromagnetic and particulate radiation. Individuals were exposed to deeply penetrating, whole-body gamma irradiation, to internal radiation emitters assimilated either by inhalation or by ingestion of contaminated water and food, and to direct radiation from material accumulating on body surfaces. That accident initiated a cascade of events, medical, social and political, which continue in varying forms to this day. Most of these have been discussed in the open medical literature and in periodic reports issued by the medical team headquartered at Brookhaven National Laboratory. This report attempts to summarize some of the principal findings of medical significnce that have been observed during the subsequent 26 years with particular emphasis on the last six years

  15. Review of medical findings in a Marshallese population twenty-six years after accidental exposure to radioactive fallout

    Energy Technology Data Exchange (ETDEWEB)

    Conard, R.A.; Paglia, D.E.; Larsen, P.R.

    1980-01-01

    In March 1954, radioactive debris from a thermonuclear weapon test at Bikini Atoll deviated from predicted trajectories and contaminated several atolls in the northern Marshall Islands. As a result, 239 native inhabitants of these islands along with 28 American servicemen and 23 Japanese fishermen received variably severe exposures to diverse ionizing radiations. Fallout material consisted largely of mixed fission products with small amounts of neutron-induced radionuclides and minimal amounts of fissionable elements, producing a complex spectrum of electromagnetic and particulate radiation. Individuals were exposed to deeply penetrating, whole-body gamma irradiation, to internal radiation emitters assimilated either by inhalation or by ingestion of contaminated water and food, and to direct radiation from material accumulating on body surfaces. That accident initiated a cascade of events, medical, social and political, which continue in varying forms to this day. Most of these have been discussed in the open medical literature and in periodic reports issued by the medical team headquartered at Brookhaven National Laboratory. This report attempts to summarize some of the principal findings of medical significnce that have been observed during the subsequent 26 years with particular emphasis on the last six years.

  16. Post-cold war United Nations peacekeeping operations: a review of the case for a hybrid level 2+ medical treatment facility.

    Science.gov (United States)

    Johnson, Ralph Jay

    2015-01-01

    Post-Cold War, UN peacekeeping operations (UN PKOs) have become larger, more mobile, multi-faceted and conducted over vast areas of remote, rugged, and harsh geography. They have been increasingly involved in dangerous areas with ill-defined boundaries, simmering internecine armed conflict, and disregard on the part of some local parties for peacekeepers' security and role. Yet progressively there have been expectations of financial restraint and austerity. Additionally, UN PKOs have become more "robust," that is, engaged in preemptive, assertive operations. A statistically positive and significant relationship exists between missions' size, complexity, remoteness, and aggressive tenor and a higher probability of trauma or death, especially as a result of hostile actions or disease. Therefore, in the interest of "force protection" and optimizing operations, a key component of UN PKOs is health care and medical treatment. The expectation is that UN PKO medical support must conform to the general intent and structure of current UN PKOs to become more streamlined, portable, mobile, compartmentalized, and specialized, but also more varied and complex to address the medical aspects of these missions cost-efficiently. This article contends that establishing a hybrid level 2-a level 2 with level 3 modules and components (i.e., level 2+)-is a viable course of action when considering trends in the medical aspects of Post-Cold War UN PKOs. A level 2 medical treatment facility has the potential to provide needed forward mobile medical treatment, especially trauma care, for extended, complex, large-scale, and comprehensive UN PKOs. This is particularly the case for missions that include humanitarian outreach, preventive medicine, and psychiatry. The level 2 treatment facility is flexible enough to expand into a hybrid level 2+ with augmentation of modules based on changes in mission requirements and variation in medical aspects.

  17. Booster main magnet power supply, present operation and potential future upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Bajon, E.; Bannon, M.; Marneris, I.; Danowski, G.; Sandberg, J.; Savatteri, S.

    2011-03-28

    The Brookhaven Booster Main Magnet Power Supply (MMPS) is a 24 pulse thyristor control supply, rated at 5500 Amps, +/-2000 Volts, or 3000 Amps, +/-6000 Volts. The power supply is fed directly from the power utility and the peak magnet power is 18 MWatts. This peak power is seen directly at the incoming ac line. This power supply has been in operation for the last 18 years. This paper will describe the present topology and operation of the power supply, the feedback control system and the different modes of operation of the power supply. Since the power supply has been in operation for the last 18 years, upgrading this power supply is essential. A new power supply topology has been studied where energy is stored in capacitor banks. DC to DC converters are used to convert the dc voltage stored in the capacitor banks to pulsed DC voltage into the magnet load. This enables the average incoming power from the ac line to be constant while the peak magnet power is pulsed to +/- 18 MWatts. Simulations and waveforms of this power supply will be presented.

  18. Why OR.NET? Requirements and perspectives from a medical user's, clinical operator's and device manufacturer's points of view.

    Science.gov (United States)

    Czaplik, Michael; Voigt, Verena; Kenngott, Hannes; Clusmann, Hans; Hoffmann, Rüdiger; Will, Armin

    2018-02-23

    In the past decades, modern medicine has been undergoing a change in the direction of digitalisation and automation. Not only the integration of new digital technologies, but also the interconnection of all components can simplify clinical processes and allow progress and development of new innovations. The integration and interconnection of medical devices with each other and with information technology (IT) systems was addressed within the framework of the Federal Ministry of Education and Research (BMBF)-funded lighthouse project OR.NET ("Secure dynamic networking in the operating room and clinic".) (OR.net-Forschungskonsortium (OR.net Research Syndicate.) OR.net - Sichere dynamische Vernetzung in Operationssaal und Klinik [Online]. Available: www.ornet.org. [last accessed 22 March 2017]). In this project the standards and concepts for interdisciplinary networking in the operating room (OR) were developed. In this paper, the diverse advantages of the OR.NET concept are presented and explained by the OR.NET "Medical Board". This board represents the forum of clinical users and includes clinicians and experts from various specialties. Furthermore, the opinion from the viewpoint of operators is presented. In a concluding comment of the "Operator Board", clinical user needs are aligned with technical requirements.

  19. BROOKHAVEN: AGS improvements

    International Nuclear Information System (INIS)

    Bleser, Ed

    1994-01-01

    The new Booster - AGS Alternating Gradient Synchrotron complex is providing beam while machine development to enhance performance also progresses, so far on schedule. In 1991 the Booster turned on and performed as requested - attesting to a successful construction and quality control programme. In 1992 beam was provided to users while the Booster met most of its operational goals - falling slightly short of its proton intensity goal of 0.5 x 10 13 protons per pulse (ppp). This would have been inconsequential except that the Booster intensity seemed to be hitting a fairly solid brick wall of undetermined origin. Since the goal for 1993 called for a doubling of the intensity, the situation seemed serious enough to schedule three months (February - April 1993) for Booster development

  20. Army Medical Support for Peace Operations and Humanitarian Assistance,

    Science.gov (United States)

    1996-01-01

    or contractors. Some coalition troops may uti - lize the theater medical system in ways it was not intended. Coalition partners’ own medical assets...agencies, and the State Depart- ment often urge the Army to expand medical services and to uti - lize any excess capacity for purposes other than the...Psychologists (new 67D). Similar concerns involved comptrollers and preventive medicine officers, field medical pharmacists , and personnel managers

  1. Design, construction, system integration, and test results of the 1 MW CW RF system for the e-gun cavity in the energy recovery LINAC at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Lenci, S.J.; Eisen, E.L.; Dickey, D.L.; Sainz, J.E.; Utay, P.F.; Zaltsman, A.; Lambiase, R.

    2009-01-01

    Brookhaven's ERL (Energy Recovery LINAC) requires a 1 MW CW RF system for the superconducting electron gun cavity. The system consists primarily of a klystron tube, transmitter, and High-Voltage Power Supply (HVPS). The 703.75 MHz klystron made by CPl, Inc. provides RF power of 1MW CW with efficiency of 65%. It has a single output window, diode-type electron gun, and collector capable of dissipating the entire beam power. It was fully factory tested including 24-hour heat run at 1.1 MW CWo The solid state HVPS designed by Continental Electronics provides up to 100 kV at low ripple and 2.1 MW CW with over 95% efficiency. With minimal stored energy and a fast shut-down mode no crowbar circuit is needed. Continental 's transmitter includes PLC based user interface and monitoring, RF pre-amplifier, magnet and Vac-Ion pump supplies, cooling water instrumentation, and integral safety interlock system. BNL installed the klystron, HVPS, and transmitter along with other items, such as circulator, water load, and waveguide components. The collaboration of BNL, CPI, and Continental in the design, installation, and testing was essential to the successful operation of the 1MW system

  2. Advanced R ampersand D for electron and photon beams at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Kirk, H.G.

    1989-08-01

    The Brookhaven Accelerator Test Facility consists of a 50-MeV linear accelerator and a laser system capable of generating short (a few picoseconds) laser pulses at both UV (266 nm) and infrared (10 μm) wavelengths. With these systems in place, the ATF has unique capabilities for the study of fundamental interactions between charged-particle beams and intense electromagnetic radiation. The principal research goals of the Accelerator Test Facility (ATF) axe the following. Laser Acceleration Program: We wig study the principles and techniques of particle acceleration at ultra-high frequencies (up to 30 THz) and with very high acceleration gradients (up to 1 GV/m). Production of Coherent Radiation: We wish to develop the next generation of photon sources with features like (a) short pulses (picoseconds or less), (b) coherence, and (c) high peak power. All of these attributes can be provided by free-electron lasers. High-brightness sources: A common denominator for the above programs is the need for electron beams with very small transverse and longitudinal emittances. We will devote a substantial amount of our resources to the production and understanding of electron beams that have these attributes. We will build advanced electron sources such as switched-power devices and rf guns with photocathodes. Important applications of this line of research include the development of high-luminosity linear colliders and free-electron lasers in the XUV regime

  3. The RaDIATE High-Energy Proton Materials Irradiation Experiment at the Brookhaven Linac Isotope Producer Facility

    Energy Technology Data Exchange (ETDEWEB)

    Ammigan, Kavin; et al.

    2017-05-01

    The RaDIATE collaboration (Radiation Damage In Accelerator Target Environments) was founded in 2012 to bring together the high-energy accelerator target and nuclear materials communities to address the challenging issue of radiation damage effects in beam-intercepting materials. Success of current and future high intensity accelerator target facilities requires a fundamental understanding of these effects including measurement of materials property data. Toward this goal, the RaDIATE collaboration organized and carried out a materials irradiation run at the Brookhaven Linac Isotope Producer facility (BLIP). The experiment utilized a 181 MeV proton beam to irradiate several capsules, each containing many candidate material samples for various accelerator components. Materials included various grades/alloys of beryllium, graphite, silicon, iridium, titanium, TZM, CuCrZr, and aluminum. Attainable peak damage from an 8-week irradiation run ranges from 0.03 DPA (Be) to 7 DPA (Ir). Helium production is expected to range from 5 appm/DPA (Ir) to 3,000 appm/DPA (Be). The motivation, experimental parameters, as well as the post-irradiation examination plans of this experiment are described.

  4. Operational experience and recent developments at the National Medical Cyclotron, Sydney

    International Nuclear Information System (INIS)

    Conard, E.M.; Arnott, D.W.

    1996-01-01

    The National Medical Cyclotron, Sydney, Australia commenced operation in mid 1991, with a mission to provide PET and SPECT radionuclides throughout Australia. The realization of the present production capacity has been synonymous with the development of the facility's industrial cyclotron (IBA Cyclone 30). The choice of cyclotron was based on the Cyclone 30's virtues as a compact, user-friendly, energy efficient cyclotron, offering the beam quality characteristic of negative ion technology. Development of the cyclotron has improved reliability and increased beam capacity, while improvements to targetry have increased production reliability. More recently, the installation and commissioning of a new solid target irradiation facility has provided much needed redundancy. This paper describes the major cyclotron and targetry developments carried out to date. (orig.)

  5. Tests of an environmental and personnel safe cleaning process for Brookhaven National Laboratory accelerator and storage ring components

    International Nuclear Information System (INIS)

    Foerster, C.L.; Lanni, C.; Lee, R.; Mitchell, G.; Quade, W.

    1997-01-01

    A large measure of the successful operation of the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL) for over a decade can be attributed to the cleaning of its ultrahigh vacuum (UHV) components during and after construction. A new UHV cleaning process, which has to be environmentally and personnel safe, is needed to replace the harsh, unfriendly process which is still in use. Dow Advanced Cleaning Systems was contracted to develop a replacement process without the use of harsh chemicals and which must clean vacuum surfaces as well as the existing process. Acceptance of the replacement process was primarily based on photon stimulated desorption (PSD) measurements of beam tube samples run on NSLS beam line U10B. One meter long beam tube samples were fabricated from aluminum, 304 stainless steel, and oxygen-free copper. Initially, coupon samples were cleaned and passed preliminary testing for the proposed process. Next, beam tube samples of each material were cleaned, and the PSD measured on beam line U10B using white light with a critical energy of 487 eV. Prior to cleaning, the samples were contaminated with a mixture of cutting oils, lubricants, vacuum oils, and vacuum grease. The contaminated samples were then baked. Samples of each material were also cleaned with the existing process after the same preparation. Beam tube samples were exposed to between 10 22 and 10 23 photons per meter for a PSD measurement. Desorption yields for H 2 , CO, CO 2 , CH 4 , and H 2 O are reported for both the existing cleaning and for the replacement cleaning process. Preliminary data, residual gas scans, and PSD results are given and discussed. The new process is also compared with new cleaning methods developed in other laboratories. After modification, the new UHV cleaning process was accepted by BNL

  6. Active implantable medical device EMI assessment for wireless power transfer operating in LF and HF bands.

    Science.gov (United States)

    Hikage, Takashi; Nojima, Toshio; Fujimoto, Hiroshi

    2016-06-21

    The electromagnetic interference (EMI) imposed on active implantable medical devices by wireless power transfer systems (WPTSs) is discussed based upon results of in vitro experiments. The purpose of this study is to present comprehensive EMI test results gathered from implantable-cardiac pacemakers and implantable cardioverter defibrillators exposed to the electromagnetic field generated by several WPTSs operating in low-frequency (70 kHz-460 kHz) and high-frequency (6.78 MHz) bands. The constructed in vitro experimental test system based upon an Irnich's flat torso phantom was applied. EMI test experiments are conducted on 14 types of WPTSs including Qi-compliant system and EV-charging WPT system mounted on current production EVs. In addition, a numerical simulation model for active implantable medical device (AIMD) EMI estimation based on the experimental test system is newly proposed. The experimental results demonstrate the risk of WPTSs emitting intermittent signal to affect the correct behavior of AIMDs when operating at very short distances. The proposed numerical simulation model is applicable to obtain basically the EMI characteristics of various types of WPTSs.

  7. Natural Resource Management Plan for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    green, T.

    2011-08-15

    This comprehensive Natural Resource Management Plan (NRMP) for Brookhaven National Laboratory (BNL) was built on the successful foundation of the Wildlife Management Plan for BNL, which it replaces. This update to the 2003 plan continues to build on successes and efforts to better understand the ecosystems and natural resources found on the BNL site. The plan establishes the basis for managing the varied natural resources located on the 5,265 acre BNL site, setting goals and actions to achieve those goals. The planning of this document is based on the knowledge and expertise gained over the past 10 years by the Natural Resources management staff at BNL in concert with local natural resource agencies including the New York State Department of Environmental Conservation, Long Island Pine Barrens Joint Planning and Policy Commission, The Nature Conservancy, and others. The development of this plan is an attempt at sound ecological management that not only benefits BNL's ecosystems but also benefits the greater Pine Barrens habitats in which BNL is situated. This plan applies equally to the Upton Ecological and Research Reserve (Upton Reserve). Any difference in management between the larger BNL area and the Upton Reserve are noted in the text. The purpose of the Natural Resource Management Plan (NRMP) is to provide management guidance, promote stewardship of the natural resources found at BNL, and to sustainably integrate their protection with pursuit of the Laboratory's mission. The philosophy or guiding principles of the NRMP are stewardship, sustainability, adaptive ecosystem management, compliance, integration with other plans and requirements, and the incorporation of community involvement, where applicable. The NRMP is periodically reviewed and updated, typically every five years. This review and update was delayed to develop documents associated with a new third party facility, the Long Island Solar Farm. This two hundred acre facility will result in

  8. Incidence, characteristics and management of pain in one operational area of medical emergency teams.

    Science.gov (United States)

    Kosiński, Sylweriusz; Bryja, Magdalena; Wojtaszowicz, Rafał; Górka, Andrzej

    2014-01-01

    Experience of pain associated with both chronic as well as acute medical conditions is a main cause for call for ambulance. The aim of this study was to establish both frequency and characteristics of pain reported by patients treated in pre-hospital environment in a single operational area. The supplementary goal was an analysis of methods of pain alleviation applied by medical personnel in the above described scenario. The written documentation of 6 months of year 2009 provided by doctor-manned as well as paramedic-only ambulances operating in Tatra county, Małopolska, Poland was analyzed. Medical personnel inquired about pain experienced in 57.4% of cases, 10-point numerical rating scale was used in 22.3% of patients. Pain was reported by 43.8% of patients, the most frequent reasons of experienced pain were trauma and cardiovascular diseases. In almost half of the cases pain was referred to the areas of chest and abdomen. Non-traumatic pain was reported by 47.7% of patients, post-traumatic in 41.3% of cases, 11% of subjects reported ischemic chest pain. 42.3% of pain-reporting patients received some form of analgesia, yet only 3% of subjects in this group received opiates. Personnel of paramedic-only ambulances tended to use pain intensity scale more often (P < 0.01), yet administered pain alleviating drugs noticeably less often than the doctor-manned teams (P < 0.01). The use of pain alleviating drugs, opiates especially, was inadequate in proportion to frequency and intensity of pain reported by patients. General, nation-wide standards of pain measurement and treatment in pre-hospital rescue are suggested as a means to improve the efficacy of pain reduction treatment.

  9. Your Lung Operation: After Your Operation

    Medline Plus

    Full Text Available ... to Participate Resources Webinars for Young Surgeons YFA E-News YFA Advocacy Essay Contest Resident and Associate ... ACS Leader International Exchange Scholar Program Resources RAS E-News Medical Students Operation Giving Back Operation Giving ...

  10. Co-operation of medical and chemical services to provide radiation safety in special zone during Chernobyl' accident response

    International Nuclear Information System (INIS)

    Terent'ev, V.I.

    1990-01-01

    Cooperation of medical and chemical services of the operation group in the special zone during intensive decontamination of the site and neighboring herritories at the Chernobyl NPP are considered. Responsibilities of medical and chemical services, their relations with civie and millitary organizations within the ChNPP region and 30-km zone are reviewed. Cooperation of the services mentioned above consisted in information exchange aimed at overall comprehension of the situation, cooperative activities in the commision and at elaboration of recommendations with an account of radiation safety measures

  11. Investigation of the effects of radiolytic-gas bubbles on the long-term operation of solution reactors for medical-isotope production

    Science.gov (United States)

    Souto Mantecon, Francisco Javier

    One of the most common and important medical radioisotopes is 99Mo, which is currently produced using the target irradiation technology in heterogeneous nuclear reactors. The medical isotope 99Mo can also be produced from uranium fission using aqueous homogeneous solution reactors. In solution reactors, 99Mo is generated directly in the fuel solution, resulting in potential advantages when compared with the target irradiation process in heterogeneous reactors, such as lower reactor power, less waste heat, and reduction by a factor of about 100 in the generation of spent fuel. The commercial production of medical isotopes in solution reactors requires steady-state operation at about 200 kW. At this power regime, the formation of radiolytic-gas bubbles creates a void volume in the fuel solution that introduces a negative coefficient of reactivity, resulting in power reduction and instabilities that may impede reactor operation for medical-isotope production. A model has been developed considering that reactivity effects are due to the increase in the fuel-solution temperature and the formation of radiolytic-gas bubbles. The model has been validated against experimental results from the Los Alamos National Laboratory uranyl fluoride Solution High-Energy Burst Assembly (SHEBA), and the SILENE uranyl nitrate solution reactor, commissioned at the Commissariat a l'Energie Atomique, in Valduc, France. The model shows the feasibility of solution reactors for the commercial production of medical isotopes and reveals some of the important parameters to consider in their design, including the fuel-solution type, 235U enrichment, uranium concentration, reactor vessel geometry, and neutron reflectors surrounding the reactor vessel. The work presented herein indicates that steady-state operation at 200 kW can be achieved with a solution reactor consisting of 120 L of uranyl nitrate solution enriched up to 20% with 235U and a uranium concentration of 145 kg/m3 in a graphite

  12. Medical x-ray

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Gui Ah Auu; Husaini Salleh; Idris Besar; Mohd Ashhar Khalid; Muhammad Jamal Md Isa; Shaharuddin Mohd; Siti Najila Mohd Janib; Mohamed Ali Abdul Khader; Mahalatchimi Dave; Mohd Fazly Abdul Rahim; Ng Chee Moon; Ram Piari; Teoh Hoon Heng; Lee Peter

    2004-01-01

    This book describes the fundamental subject about medical radiography. It is a multidisciplinary field that requires cross professional input from scientists, engineers and medical doctors. However, it is presented in simple language to suit different levels of readers from x-ray operators and radiographers to physists, general practitioners and radiology specialists.The book is written in accordance to the requirements of the standard syllabus approved by the Ministry of Health Malaysia for the training of medical x-ray operator and general practitioners. In general, the content is not only designed to provide relevant and essential subject for related professionals in medical radiological services such as x-ray operator, radiographer and radiologists, but also to address those in associated radiological services including nurses, medical technologists and physicists.The book is organized and arranged sequentially into 3 parts for easy reference: Radiation safety; X-ray equipment and associated facilities; Radiography practices. With proper grasping of all these parts, the radiological services could be provided with confident and the highest professional standard. Thus, medical imaging with highest quality that can provide useful diagnostic information at minimum doses and at cost effective could be assured

  13. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal fires during mid-loop operations. Volume 3, Part 1, Main report

    International Nuclear Information System (INIS)

    Musicki, Z.; Chu, T.L.; Yang, J.; Ho, V.; Hou, Y.M.; Lin, J.; Siu, N.

    1994-07-01

    During l989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than fun power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in ' the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. We recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few. procedures are available for mitigating accidents that may occur during shutdown. Procedures written specifically for shutdown accidents would be useful

  14. Operational measurements in radioprotection in the industrial and medical environments

    International Nuclear Information System (INIS)

    Rodde, S.; Vial, Th.; Truffert, H.; Kramar, R.; Batalla, A.; Roine, Ph.; Pin, A.; Lahaye, Th.; Rodde, S.; Bordy, J.M.; Paquet, F.; Veres, A.; Cadiou, A.; Branthonne, J.Y.; Noel, A.; Laloubere, L.; Moreau, St.; Gensdarmes, F.; Marques, S.; Lestang, M.; Valendru, N.; Tranchant, Ph.; Martel, P.; Bernhard, S.; Chareyre, P.; Gardin, I.; Casanova, Ph.; De Vita, A.; Tenailleau, L.; Masson, B.; Feret, B.; Guerin, M.; Guillot, L.; Gaultier, E.

    2009-01-01

    This document gathers the slides of the available presentations given during these conference days. Thirty presentations are assembled in the document and deal with: 1 - enforcement circular of the labor code dispositions relative to workers protection against ionizing radiation hazards (T. Lahaye); 2 - context and regulatory evolutions - public health code (S. Rodde); 3 - references and perspectives in external dosimetry (J.M. Bordy); 4 - CIPR's Committee 2 works (F. Paquet); 5 - from protection data to measurement data (A. Pin); 6 - dosimetric control in radiotherapy (A. Veres); 7 - calibration of irradiation measurement devices in industrial environment (A. Cadiou); 8 - calibration and verification of nuclear measurement devices (J.Y. Branthonne); 9 - calibration of measurement devices in medical environment (J.M. Bordy); 10 - quality control in radiotherapy (A. Batalla); 11 - in-vivo dosimetry in radiotherapy (A. Noel); 12 - calibration metrology of fixed post irradiation sensors (L. Laloubere); 13 - design requirements for the radiological zoning and the wastes cleanliness of Flamanville 3 EPR reactor (S. Moreau); 14 - efficiency of aerosol capture systems used in CNPE EDF (F. Gensdarmes); 15 - mobile surveillance means of the atmospheric contamination of CNPE EDF's reactor building (S. Marques and M. Lestang); 16 - experience feedback about the security gates at EDF's nuclear facilities (N. Valendru); 17 - metrology needs for radioprotection technical controls (P. Tranchant); 18 - technical evaluation of a flowmeter/dosemeter in the framework of the regulatory control of X-ray electric generators used in radio-diagnosis (P. Martel); 19 - reinforced natural radioactivity - the case of radon measurement (S. Bernhard); 20 - fires during radioactive materials transport (P. Chareyre); 21 - measurement in the framework of medical examinations: radiology service (A. Noel); 22 - operational measurements in nuclear medicine (I. Gardin); 23 - from the operational

  15. Dedicated search for the time evolution of an electron neutrino beam at the Brookhaven AGS

    International Nuclear Information System (INIS)

    Bionta, R.; LoSecco, J.; Ong, R.; Stone, J.; Sulak, L.; Watts, R.; Cortez, B.; Foster, G.W.

    1981-01-01

    An experiment dedicated to the study of the time evolution of a neutrino beam enriched with ν/sub e/'s is suggested as feasible. It appears that the highest fluxes can be achieved with current beam lines at the Brookhaven AGS or the CERN PS. A configuration optimized for good sensitivity to neutrino eigenmass differences from 1 eV to 20 eV and mixing (Pontecorvo) angles down to 15 0 (comparable to the Cabibbo angle) is considered. The ν/sub e/ beam is formed using K/sub e3/ 0 decays. A simultaneously produced ν/sub μ/ beam from K/sub μ3/ 0 decay serves as the normalizer. Pion generated ν/sub μ/'s are suppressed to limit background. A massive detector is employed to obtain sufficient statistical power. It consists of a series of seven water Cerenkov modules (each with 180T fiducial mass), judiciously spaced along the ν line to provide flight paths from 40 m to 1000 m. The detector elements duplicate a recently developed technology that is eminently suited to this investigation. Simulation and reconstruction of neutrino events in a detector similar to the one suggested show sufficient resolution in angle, energy, position and event timing relative to the beam

  16. RHIC and quark matter: proposal for a relativistic heavy ion collider at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    1984-08-01

    This document describes the Brookhaven National Laboratory Proposal for the construction of a Relativistic Heavy Ion Collider (RHIC). The construction of this facility represents the natural continuation of the laboratory's role as a center for nuclear and high-energy physics research and extends and uses the existing AGS, Tandem Van de Graaff and CBA facilities at BNL in a very cost effective manner. The Administration and Congress have approved a project which will provide a link between the Tandem Van de Graaf and the AGS. Completion of this project in 1986 will provide fixed target capabilities at the AGS for heavy ions of about 14 GeV/amu with masses up to approx. 30 (sulfur). The addition of an AGS booster would extend the mass range to the heaviest ions (A approx. 200, e.g., gold); its construction could start in 1986 and be completed in three years. These two new AGS experimental facilities can be combined with the proposed Relativistic Heavy Ion Collider to extend the energy range to 100 x 100 GeV/amu for the heaviest ions. BNL proposes to start construction of RHIC in FY 86 with completion in FY 90 at a total cost of 134 M$

  17. Accreditation Council for Graduate Medical Education (ACGME) Surgery Resident Operative Logs: The Last Quarter Century.

    Science.gov (United States)

    Drake, Frederick Thurston; Aarabi, Shahram; Garland, Brandon T; Huntington, Ciara R; McAteer, Jarod P; Richards, Morgan K; Zern, Nicole Kansier; Gow, Kenneth W

    2017-05-01

    To describe secular trends in operative experience for surgical trainees across an extended period using the most comprehensive data available, the Accreditation Council for Graduate Medical Education (ACGME) case logs. Some experts have expressed concern that current trainees are inadequately prepared for independent practice. One frequently mentioned factor is whether duty hours' restrictions (DHR) implemented in 2003 and 2004 contributed by reducing time spent in the operating room. A dataset was generated from annual ACGME reports. Operative volume for total major cases (TMC), defined categories, and four index laparoscopic procedures was evaluated. TMC dropped after implementation of DHR but rebounded after a transition period (949 vs 946 cases, P = nonsignificance). Abdominal cases increased from 22% of overall cases to 31%. Alimentary cases increased from 21% to 26%. Trauma and vascular surgery substantially decreased. For trauma, this drop took place well before DHR. The decrease in vascular surgery also began before DHR but continued afterward as well: 148 cases/resident in the late 1990s to 107 currently. Although total operative volume rebounded after implementation of DHR, diversity of operative experienced narrowed. The combined increase in alimentary and abdominal cases is nearly 13%, over a half-year's worth of operating in 5-year training programs. Bedrock general surgery cases-trauma, vascular, pediatrics, and breast-decreased. Laparoscopic operations have steadily increased. If the competence of current graduates has, in fact, diminished. Our analysis suggests that operative volume is not the problem. Rather, changing disease processes, subspecialization, reductions in resident autonomy, and technical innovation challenge how today's general surgeons are trained.

  18. Medical Operations Decision Support System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Determining the probability of specific medical events on a given space mission is difficult. Yet, it is important to have reasonable estimates of these...

  19. A literature review of medical aspects of post-cold war UN peacekeeping operations: trends, lessons learnt, courses of action and recommendations.

    Science.gov (United States)

    Johnson, Ralph Jay

    2016-08-01

    Post-Cold War United Nations Peace Keeping Operations (UN PKOs) have been increasingly involved in dangerous areas with ill-defined boundaries, harsh and remote geographies, simmering internecine armed conflict and disregard on the part of some local parties for peacekeepers' security and role. In the interest of 'force protection' and optimising operations, a key component of UN PKOs is healthcare and medical treatment. The expectation is that UN PKO medical support will conform to the general intent and structure of UN PKOs. To do so requires effective policies and planning informed by a review of medical aspects crucial to UN PKOs. The intent of this article is to report on a review of principal medical aspects practical to post-Cold War UN PKOs. This review was assembled through a comprehensive, grounded, systematic iterative inquiry of open-source articles. This inquiry revealed that the principal medical aspects in post-Cold War UN missions were the following: (1) the changed nature of UN PKOs, (2) new challenges in terms of proximity and distance to medical care, (3) expanded need for preventive medicine and disease contagion prevention and (4) increased propensity for psychological morbidity and need for intervention. Post Cold War, the dramatically changed nature of UN PKOs has resulted in new challenges mainly in terms of medical logistics, preventive medicine and psychiatry. The changed nature of post-Cold War UN PKOs altered the character of medical support most notably regarding (1) a need for emphasis on immediate response proximate to medical events and rapid transport over long distances and traversing barriers to higher levels of care, (2) proactive contagion and hazard identification and prevention and (3) interventions designed to reduce psychological morbidity. Recommendations are offered about possible courses of action in terms of addressing trends found in identified medical aspects of PKOs. Published by the BMJ Publishing Group Limited. For

  20. Code of practice for the design and safe operation of non-medical irradiation facilities (1988)

    International Nuclear Information System (INIS)

    1988-01-01

    This Code establishes requirements for the design and operation of irradiation facilities which use X-rays, electrons or gamma radiation for non-medical purposes such as the sterilisation of therapeutic goods. These requirements aim to ensure that exposure of workers and members of the public to ionizing and non-ionizing radiation as well as to noxious gases and radioactive contamination of the environment and facilities are controlled through the design of engineering safety features, approved administrative controls and appropriate radiation monitoring [fr

  1. USE OF ELECTRONIC CASE HISTORIES IN OPERATION OF MEDICAL UNITS

    Directory of Open Access Journals (Sweden)

    I. B. Boltenkova

    2016-01-01

    Full Text Available Introduction of electronic case histories to medical units including TB units is one of the factors allowing enhancing quality of medical care provision. Use of the electronic case histories provides conditions for information transparency improvement in a medical unit: financial, statistic and medico-technological. Information contained in the electronic case history is important and required both for internal and external use. Use of electronic case histories contributes to reduction of labor costs of workers in medical units, provides fast access of medical personnel to information, formalizes data, provides preservation, invariance and reliability of the information entered into electronic case history during the whole period of storage, regulates the access rights and confidentiality, personifies data and allows unifying health data of all Russian population into one pool.

  2. People and things. CERN Courier, April 1980, v. 20(2)

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    The article reports on achievements of various people, staff changes and position opportunities within the CERN organization and contains news updates on upcoming or past events: On 22 May Brookhaven National Laboratory will celebrate the twentieth year of operation of the Alternating Gradient Synchrotron; Japanese scientists are becoming involved in extensive collaborations at US high energy physics Laboratories (Argonne, Berkeley, Brookhaven, Fermi lab and Stanford)

  3. [Intelligent operating room suite : From passive medical devices to the self-thinking cognitive surgical assistant].

    Science.gov (United States)

    Kenngott, H G; Wagner, M; Preukschas, A A; Müller-Stich, B P

    2016-12-01

    Modern operating room (OR) suites are mostly digitally connected but until now the primary focus was on the presentation, transfer and distribution of images. Device information and processes within the operating theaters are barely considered. Cognitive assistance systems have triggered a fundamental rethinking in the automotive industry as well as in logistics. In principle, tasks in the OR, some of which are highly repetitive, also have great potential to be supported by automated cognitive assistance via a self-thinking system. This includes the coordination of the entire workflow in the perioperative process in both the operating theater and the whole hospital. With corresponding data from hospital information systems, medical devices and appropriate models of the surgical process, intelligent systems could optimize the workflow in the operating theater in the near future and support the surgeon. Preliminary results on the use of device information and automatically controlled OR suites are already available. Such systems include, for example the guidance of laparoscopic camera systems. Nevertheless, cognitive assistance systems that make use of knowledge about patients, processes and other pieces of information to improve surgical treatment are not yet available in the clinical routine but are urgently needed in order to automatically assist the surgeon in situation-related activities and thus substantially improve patient care.

  4. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal events during mid-loop operations, Main report (Chapters 7--12). Volume 2, Part 1B

    International Nuclear Information System (INIS)

    Chu, T.L.; Musicki, Z.; Kohut, P.

    1994-06-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. We recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few procedures are available for mitigating accidents that may occur during shutdown. Procedures written specific shutdown accidents would be useful

  5. Operation of a general purpose stepping motor-encoder positioning subsystem at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Stubblefield, F.W.

    1985-11-01

    Four copies of a general purpose subsystem for mechanical positioning of detectors, samples, and beam line optical elements which constitute experiments at the National Synchrotron Light Source facility of Brookhaven National Laboratory have been constructed and placed into operation. Construction of a fifth subsystem unit is nearing completion. The subsystems affect mechanical positioning by controlling a set of stepping motor-encoder pairs. The units are general purpose in the sense that they receive commands over a 9600 baud asynchronous serial line compatible with the RS-232-C electrical signal standard, generate TTL-compatible streams of stepping pulses which can be used with a wide variety of stepping motors, and read back position values from a number of different types and models of position encoder. The basic structure of the motor controller subsystem is briefly reviewed. Additions to the subsystem made in response to problems indicated by actual operation of the four installed units are described in more detail

  6. Results and insights of internal fire and internal flood analyses of the Surry Unit 1 Nuclear Power Plant during mid-loop operations

    International Nuclear Information System (INIS)

    Chu, Tsong-Lun; Musicki, Z.; Kohut, P.

    1995-01-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). The objectives of the program are to assess the risks of severe accidents initiated during plant operational states (POSs) other than full power operation and to compare the estimated core damage frequencies (CDFs), important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program includes that of a Level 3 PRA for internal events and a Level 1 PRA for seismically induced and internal fire and flood induced core damage sequences. This paper summarizes the results and highlights of the internal fire and flood analysis documented in Volumes 3 and 4 of NUREG/CR-6144 performed for the Surry plant during mid-loop operation

  7. Operational experience and recent developments at the National Medical Cyclotron

    International Nuclear Information System (INIS)

    Conard, E.; Pac, B.; Arnott, D.W.

    1994-01-01

    The National Medical Cyclotron is a radioisotope production facility run by ANSTO and located on the grounds of the Royal Prince Alfred Hospital in Sydney, Australia. A CYCLONE 30 (IBA) cyclotron is used in the production of short-lived PET radiopharmaceuticals required by the hospital's PET Scanner and also to produce a number of bulk radiochemicals for processing and distribution throughout Australasia. Following commissioning of the cyclotron and beam lines in October 1991, and the overcoming of a number of early open-quote teething close-quote problems especially relating to the reliability of the r.f. and solid target transport systems, a steady program of improvements has been pursued. These improvements have included development of new beam diagnostics and the design and installation of a new beam line for SPECT radioisotope production. The current operations schedule includes the production of 18 FDG, 13 NH 3 , 15 O 2 and 201 Tl, 67 Ga and 123 I. This paper will discuss the process of development of the cyclotron to ably meet the present demands on it, and the problems resolved in the pursuit of this goal

  8. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal events during mid-loop operations, Appendices A--D. Volume 2, Part 2

    International Nuclear Information System (INIS)

    Chu, T.L.; Musicki, Z.; Kohut, P.

    1994-06-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the Potential risks during low Power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the Plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. We recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few procedures are available for mitigating accidents that may occur during shutdown. Procedures written specifically for shutdown accidents would be useful. This document, Volume 2, Pt. 2 provides appendices A through D of this report

  9. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal events during mid-loop operations, Appendices A--D. Volume 2, Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Musicki, Z.; Kohut, P. [Brookhaven National Lab., Upton, NY (United States)] [and others

    1994-06-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the Potential risks during low Power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the Plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. We recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few procedures are available for mitigating accidents that may occur during shutdown. Procedures written specifically for shutdown accidents would be useful. This document, Volume 2, Pt. 2 provides appendices A through D of this report.

  10. Final environmental impact statement, construction and operation of the Spallation Neutron Source Facility. Summary

    International Nuclear Information System (INIS)

    1999-04-01

    DOE proposes to construct and operate a state-of-the-art, short-pulsed, spallation neutron source comprised of an ion source, a linear accelerator, a proton accumulator ring, and an experiment building containing a liquid mercury target and a suite of neutron scattering instrumentation. The proposed Spallation Neutron Source would be designed to operate at a proton beam power of 1 megawatt. The design would accommodate future upgrades to a peak operating power of 4 megawatts. These upgrades may include construction of a second proton accumulator ring and a second target. This document analyzes the potential environmental impacts from the proposed action and the alternatives. The analysis assumes a facility operating at a power of 1 MW and 4 MW over the life of the facility. The two primary alternatives analyzed in this FEIS are: the proposed action (to proceed with building the Spallation Neutron Source) and the No-Action Alternative. The No-Action Alternative describes the expected condition of the environment if no action were taken. Four siting alternatives for the Spallation Neutron Source are evaluated: Oak Ridge National Laboratory, Oak Ridge, TN, (preferred alternative); Argonne National Laboratory, Argonne, IL; Brookhaven National Laboratory, Upton, NY; and Los Alamos National Laboratory, Los Alamos, NM

  11. Final environmental impact statement, construction and operation of the Spallation Neutron Source. Volume 1

    International Nuclear Information System (INIS)

    1999-04-01

    DOE proposes to construct and operate a state-of-the-art, short-pulsed, spallation neutron source comprised of an ion source, a linear accelerator, a proton accumulator ring, and an experiment building containing a liquid mercury target and a suite of neutron scattering instrumentation. The proposed Spallation neutron Source would be designed to operate at a proton beam power of 1 megawatt. The design would accommodate future upgrades to a peak operating power of 4 megawatts. These upgrades may include construction of a second proton accumulator ring and a second target. This document analyzes the potential environmental impacts from the proposed action and the alternatives. The analysis assumes a facility operating at a power of 1 MW and 4 MW over the life of the facility. The two primary alternatives analyzed in this FEIS are: the proposed action (to proceed with building the Spallation Neutron Source) and the No-Action Alternative. The No-Action Alternative describes the expected condition of the environment if no action were taken. Four siting alternatives for the Spallation Neutron Source are evaluated: Oak Ridge National Laboratory, Oak Ridge, TN, (preferred alternative); Argonne National Laboratory, Argonne, IL; Brookhaven National Laboratory, Upton, NY; and Los Alamos National Laboratory, Los Alamos, NM

  12. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal events during mid-loop operations, Appendices E (Sections E.1--E.8). Volume 2, Part 3A

    International Nuclear Information System (INIS)

    Chu, T.L.; Musicki, Z.; Kohut, P.

    1994-06-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. The authors recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few procedures are available for mitigating accidents that may occur during shutdown. Procedures written specifically for shutdown accidents would be useful

  13. Special Forces Medical Sergeants' perceptions and beliefs regarding their current medical sustainment program: implications for the field.

    Science.gov (United States)

    Wilson, Ramey L; DeZee, Kent J

    2014-01-01

    Special Forces Medical Sergeants (SFMS) are trained to provide trauma and medical care in support of military operations and diplomatic missions throughout the world with indirect physician oversight. This study assessed their perceptions of the current program designed to sustain their medical skills. An Internet-based survey was developed using the constructs of the Theory of Reasoned Action/Planned Behavior and validated through survey best practices. Of the 334 respondents, 92.8% had deployed at least once as an SFMS. Respondents reported spending 4 hours per week sustaining their medical skills and were highly confident that they could perform their duties on a no-notice deployment. On a 5-point, Likert-type response scale, SFMS felt that only slight change is needed to the Special Operations Medical Skills Sustainment Course (mean: 2.17; standard deviation [SD]: 1.05), while moderate change is needed to the Medical Proficiency Training (mean: 2.82; SD: 1.21) and nontrauma modules (mean: 3.02; SD: 1.22). Respondents desire a medical sustainment program that is provided by subject matter experts, involves actual patient care, incorporates new technology, uses hands-on simulation, and is always available. SFMS are challenged to sustain their medical skills in the current operational environment, and barriers to medical training should be minimized to facilitate sustainment training. Changes to the current medical sustainment program should incorporate operator-level perspectives to ensure acceptability and utility but must be balanced with organizational realities. Improving the medical sustainment program will prepare SFMS for the challenges of future missions. 2014.

  14. Construction and Operational Experience with a Superconducting Octupole Used to Trap Antihydrogen

    Energy Technology Data Exchange (ETDEWEB)

    Wanderer P.; Escallier, J.; Marone, A.; Parker, B.

    2011-09-06

    A superconducting octupole magnet has seen extensive service as part of the ALPHA experiment at CERN. ALPHA has trapped antihydrogen, a crucial step towards performing precision measurements of anti-atoms. The octupole was made at the Direct Wind facility by the Superconducting Magnet Division at Brookhaven National Laboratory. The magnet was wound with a six-around-one NbTi cable about 1 mm in diameter. It is about 300 mm long, with a radius of 25 mm and a peak field at the conductor of 4.04 T. Specific features of the magnet, including a minimal amount of material in the coil and coil ends with low multipole content, were advantageous to its use in ALPHA. The magnet was operated for six months a year for five years. During this time it underwent about 900 thermal cycles (between 4K and 100K). A novel operational feature is that during the course of data-taking the magnet was repeatedly shut off from its 950 A operating current. The magnet quenches during the shutoff, with a decay constant of 9 ms. Over the course of the five years, the magnet was deliberately quenched many thousands of times. It still performs well.

  15. Telementoring systems in the operating room: a new approach in medical training.

    Science.gov (United States)

    Wachs, Juan P; Gomez, Gerardo

    2013-01-01

    This paper discusses the challenges and innovations related to the use of telementoring systems in the operating room. Most of the systems presented leverage on three types of interaction channels: audio, visual and physical. The audio channel enables the mentor to verbally instruct the trainee, and allows the trainee to ask questions. The visual channel is used to deliver annotations, alerts and other messages graphically to the trainee during the surgery. These visual representations are often displayed through a telestrator. The physical channel has been used in laparoscopic procedures by partially controlling the laparoscope through force-feedback. While in face to face instruction, the mentor produces gestures to convey certain aspects of the surgical instruction, there is not equivalent of this form of physical interaction between the mentor and trainee in open surgical procedures in telementoring systems. Even that the trend is to perform more minimally invasive surgery (MIS), trauma surgeries are still necessary, where initial resuscitation and stabilization of the patient in a timely manner is crucial. This paper presents a preliminary study conducted at the Indiana University Medical School and Purdue University, where initial lexicons of surgical instructive gestures (SIGs) were determined through systematic observation when mentor and trainee operate together. The paper concludes with potential ways to convey gestural information through surgical robots.

  16. Telementoring systems in the operating room: a new approach in medical training

    Directory of Open Access Journals (Sweden)

    Juan P. Wachs

    2013-12-01

    Full Text Available This paper discusses the challenges and innovations related to the use of telementoring systems in the operating room. Most of the systems presented leverage on three types of interaction channels: audio, visual and physical. The audio channel enables the mentor to verbally instruct the trainee, and allows the trainee to ask questions. The visual channel is used to deliver annotations, alerts and other messages graphically to the trainee during the surgery. These visual representations are often displayed through a telestrator. The physical channel has been used in laparoscopic procedures by partially controlling the laparoscope through force-feedback. While in face to face instruction, the mentor produces gestures to convey certain aspects of the surgical instruction, there is not equivalent of this form of physical interaction between the mentor and trainee in open surgical procedures in telementoring systems. Even that the trend is to perform more minimally invasive surgery (MIS, trauma surgeries are still necessary, where initial resuscitation and stabilization of the patient in a timely manner is crucial. This paper presents a preliminary study conducted at the Indiana University Medical School and Purdue University, where initial lexicons of surgical instructive gestures (SIGs were determined through systematic observation when mentor and trainee operate together. The paper concludes with potential ways to convey gestural information through surgical robots.

  17. Confirmatory simulation of safety and operational transients in LMFBR systems

    International Nuclear Information System (INIS)

    Guppy, J.G.; Agrawal, A.K.

    1978-01-01

    Operational and safety transients (anticipated, unlikely, or extremely unlikely) that may originate anywhere in a liquid-metal fast breeder reactor (LMFBR) system must be adequately simulated to assist in safety evaluation and plant design efforts. An advanced thermohydraulic transient code, the Super System Code (SSC), is described that may be used for confirmatory safety evaluations of plant-wide events, such as assurance of adequate decay heat removal capability under natural circulation conditions. Results obtained with SSC illustrating the degree of modeling detail present in the code as well as the computing efficiency are presented. A version of the SSC code, SSC-L, applicable to any loop-type LMFBR design, has been developed at Brookhaven. The scope of SSC-L is to enable the simulation of all plant-wide transients covered by Plant Protection System (PPS) action, including sodium pipe rupture and coastdown to natural circulation conditions. The computations are stopped when loss of core integrity (i.e., clad melting temperature exceeded) is indicated

  18. Medication deserts: survey of neighborhood disparities in availability of prescription medications

    Science.gov (United States)

    2012-01-01

    Background Only a small amount of research has focused on the relationship between socio-economic status (SES) and geographic access to prescription medications at community pharmacies in North America and Europe. To examine the relationship between a community’s socio-economic context and its residents’ geographic access to common medications in pharmacies, we hypothesized that differences are present in access to pharmacies across communities with different socio-economic environments, and in availability of commonly prescribed medications within pharmacies located in communities with different socio-economic status. Methods We visited 408 pharmacies located in 168 socio-economically diverse communities to assess the availability of commonly prescribed medications. We collected the following information at each pharmacy visited: hours of operation, pharmacy type, in-store medication availability, and the cash price of the 13 most commonly prescribed medications. We calculated descriptive statistics for the sample and fitted a series of hierarchical linear models to test our hypothesis that the in-stock availability of medications differs by the socio-economic conditions of the community. This was accomplished by modeling medication availability in pharmacies on the socio-economic factors operating at the community level in a socio-economically devise urban area. Results Pharmacies in poor communities had significantly higher odds of medications being out of stock, OR=1.24, 95% CI [1.02, 1.52]. There was also a significant difference in density of smaller, independent pharmacies with very limited stock and hours of operation, and larger, chain pharmacies in poor communities as compared to the middle and low-poverty communities. Conclusions The findings suggest that geographic access to a neighborhood pharmacy, the type of pharmacy, and availability of commonly prescribed medications varies significantly across communities. In extreme cases, entire communities

  19. Tritium toxicity program in the Medical Department, Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Carsten, A.L.

    1983-01-01

    It is possible to detect somatic, cytogenetic and genetic effects resulting from exposures at 33 to 100 times the mpc's for tritiated water (HTO). The reduction in bone marrow cells in animals maintaining normal total cellularity demonstrate both the presence of an effect at the primitive cell level as well as the animal's ability to compensate for this effect by recruiting stem cells from the G 0 resting state. This evidence of damage together with the observed cytogenetic changes leads one to contemplate the possible importance of radiation exposures at these levels for the induction of leukemia or other blood dyscrasias. As predicted on the basis of established principles of radiobiology, exposure to tritium beta rays from HTO ingestion results in measureable effects on several animal systems

  20. AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY DISEASE STATE CLINICAL REVIEW: MANAGEMENT OF ACROMEGALY PATIENTS: WHAT IS THE ROLE OF PRE-OPERATIVE MEDICAL THERAPY?

    Science.gov (United States)

    Fleseriu, Maria; Hoffman, Andrew R; Katznelson, Laurence

    2015-06-01

    Acromegaly is a complex disease characterized by growth hormone (GH) excess originating in most cases from a pituitary tumor. The goals of treatment include removing the tumor or reducing tumor burden, normalizing GH secretion and insulin-like growth factor 1 levels, and preserving normal pituitary function if possible. Surgery by an experienced neurosurgeon is still considered first-line therapy, especially in cases with small tumors. In the last few decades, significant progress in the development of selective pharmacologic agents has greatly facilitated the management of active acromegaly, with agents such as somatostatin-receptor ligands (SRLs), GH-receptor antagonists, and dopamine agonists. In addition to adjuvant treatment, pre-operative medical therapy and primary therapy in de novo patients are increasingly employed. A United States National Library of Medicine PubMed search (through July 2014) was conducted for the following terms: acromegaly, pre-operative medical therapy, somatostatin-receptor ligands, and somatostatin analogs. Articles not in English and those not in peer-reviewed journals were excluded. In reviewing pertinent articles, focus was placed on biochemical and other postoperative outcomes of medical therapy. An analysis of the full effect of pre-operative use of SRLs on surgical outcomes (remission rates and peri-operative complications) is limited by heterogeneity of methodology, low overall surgical cure rates, and different study designs. The assumption that SRL use prior to surgery reduces peri-operative surgical risk has yet to be proven. A variable degree of tumor shrinkage with preoperative SRLs is observed. Likewise, SRL treatment 3 months before surgery may improve surgical remission rates in the short term; however, positive results do not persist in the long term. We consider that medical therapy before surgery could play a role in carefully selected patients, but treatment should be individualized. Primary medical therapy with a

  1. The construction and operating characteristics of a cathode strip chamber system designed to measure the reaction vertices of a stopping kaon beam

    International Nuclear Information System (INIS)

    M.W. Ahmed; D. Androic; I. Bertovic; J. Bjoraker; R. Chrien; X. Cui; D. Dehnhard; Anton Empl; M. Furic; J. Gerald; R. Gill; E.V. Hungerford; H. Jungst; K.J. Lan; Jinghua Liu; C.L. Morris; J.M. O'Donnell; J.C. Peng; T. Petkovic; P. Pile; M. Planinic; C.M. Riedel; A. Rusek; R. Sutter; Liguang Tang; H.A. Thiessen; M. Youn; V. Zeps

    2001-01-01

    The design, construction, and performance of a segmented-target, cathode-strip, tracking-detector is discussed. The chamber was made of low-Z materials in order to allow photons to leave the target region. It was used to determine the reaction vertex of stopping kaons, and was successfully operated in a high-intensity kaon beamline at the Alternating Gradient Synchrotron at Brookhaven National Laboratory. The vertical and horizontal resolutions of the stopping kaon reaction positions were sigma X∼ 0.454mm and sigma Y∼ 1.180mm, respectively. The uncertainty in the longitudinal (Z) direction is given by one-half the thickness of a target segment

  2. The construction and operating characteristics of a cathode strip chamber system designed to measure the reaction vertices of a stopping kaon beam

    International Nuclear Information System (INIS)

    Ahmed, M.W.; Androic, D.; Bertovic, I.; Bjoraker, J.; Chrien, R.; Cui, X.; Dehnhard, D.; Empl, A.; Furic, M.; Gerald, J.; Gill, R.; Hungerford, E.V.; Juengst, H.; Lan, K.J.; Liu, J.H.; Morris, C.L.; O'Donnell, J.M.; Peng, J.C.; Petkovic, T.; Pile, P.; Planinic, M.; Riedel, C.M.; Rusek, A.; Sutter, R.; Tang, L.; Thiessen, H.A.; Youn, M.; Zeps, V.

    2001-01-01

    The design, construction, and performance of a segmented-target, cathode-strip, tracking-detector is discussed. The chamber was made of low-Z materials in order to allow photons to leave the target region. It was used to determine the reaction vertex of stopping kaons, and was successfully operated in a high-intensity kaon beamline at the Alternating Gradient Synchrotron at Brookhaven National Laboratory. The vertical and horizontal resolutions of the stopping kaon reaction positions were σ X ∼0.454 mm and σ Y ∼1.180 mm, respectively. The uncertainty in the longitudinal (Z) direction is given by one-half the thickness of a target segment

  3. The construction and operating characteristics of a cathode strip chamber system designed to measure the reaction vertices of a stopping kaon beam

    CERN Document Server

    Ahmed, M W; Bertovic, I; Bjoraker, J; Chrien, R; Cui, X; Dehnhard, D; Empl, A; Furic, M; Gerald, J; Gill, R; Hungerford, E V; Juengst, H; Lan, K J; Liu, J H; Morris, C L; O'donnell, J M; Peng, J C; Petkovic, T; Pile, P; Planinic, M; Riedel, C M; Rusek, A; Sutter, R; Tang, L; Thiessen, H A; Youn, M; Zeps, V

    2001-01-01

    The design, construction, and performance of a segmented-target, cathode-strip, tracking-detector is discussed. The chamber was made of low-Z materials in order to allow photons to leave the target region. It was used to determine the reaction vertex of stopping kaons, and was successfully operated in a high-intensity kaon beamline at the Alternating Gradient Synchrotron at Brookhaven National Laboratory. The vertical and horizontal resolutions of the stopping kaon reaction positions were sigma sub X approx 0.454 mm and sigma sub Y approx 1.180 mm, respectively. The uncertainty in the longitudinal (Z) direction is given by one-half the thickness of a target segment.

  4. Regulatory Compliance to Assure the Safety of the Operation of a Medical Cyclotron

    International Nuclear Information System (INIS)

    Dela Cruz, Joselito

    2015-01-01

    Khealth Corporation, in Partnership with the National Kidney and Transplant Institute, has established a medical cyclotron facility to accommodate the up-and-coming needs of tracers for PET/CT in different centers and hospitals all over the country. This facility houses a 16.5 MeV GE PET trace 880 particle accelerator that can produce 14 Ci (518 GBq) of Fluorine-18. Its structure has adopted global standard designs in meeting the safety during its use, radiopharmaceutical production and distribution. Compliances were remarkably fulfilled from the building construction, machine acquisition, commissioning, operations up to the quality control and assurance. Furthermore, various regulatory challenges during the current standardization of radiopharmaceutical utilization were encountered however time dedication and efforts were wielded until all have been successfully justified and acquired. (author)

  5. [Prevention of medical device-related adverse events in hospitals: Specifying the recommendations of the German Coalition for Patient Safety (APS) for users and operators of anaesthesia equipment].

    Science.gov (United States)

    Bohnet-Joschko, Sabine; Zippel, Claus; Siebert, Hartmut

    2015-01-01

    The use and organisation of medical technology has an important role to play for patient and user safety in anaesthesia. Specification of the recommendations of the German Coalition for Patient Safety (APS) for users and operators of anaesthesia equipment, explore opportunities and challenges for the safe use and organisation of anaesthesia devices. We conducted a literature search in Medline/PubMed for studies dealing with the APS recommendations for the prevention of medical device-related risks in the context of anaesthesia. In addition, we performed an internet search for reports and recommendations focusing on the use and organisation of medical devices in anaesthesia. Identified studies were grouped and assigned to the recommendations. The division into users and operators was maintained. Instruction and training in anaesthesia machines is sometimes of minor importance. Failure to perform functional testing seems to be a common cause of critical incidents in anaesthesia. There is a potential for reporting to the federal authority. Starting points for the safe operation of anaesthetic devices can be identified, in particular, at the interface of staff, organisation, and (anaesthesia) technology. The APS recommendations provide valuable information on promoting the safe use of medical devices and organisation in anaesthesia. The focus will be on risks relating to the application as well as on principles and materials for the safe operation of anaesthesia equipment. Copyright © 2015. Published by Elsevier GmbH.

  6. Biomedical programs operations plans

    Science.gov (United States)

    Walbrecher, H. F.

    1974-01-01

    Operational guidelines for the space shuttle life sciences payloads are presented. An operational assessment of the medical experimental altitude test for Skylab, and Skylab life sciences documentation are discussed along with the operations posture and collection of space shuttle operational planning data.

  7. Evaluation of Randomly Selected Completed Medical Records Sheets in Teaching Hospitals of Jahrom University of Medical Sciences, 2009

    Directory of Open Access Journals (Sweden)

    Mohammad Parsa Mahjob

    2011-06-01

    Full Text Available Background and objective: Medical record documentation, often use to protect the patients legal rights, also providing information for medical researchers, general studies, education of health care staff and qualitative surveys is used. There is a need to control the amount of data entered in the medical record sheets of patients, considering the completion of these sheets is often carried out after completion of service delivery to the patients. Therefore, in this study the prevalence of completeness of medical history, operation reports, and physician order sheets by different documentaries in Jahrom teaching hospitals during year 2009 was analyzed. Methods and Materials: In this descriptive / retrospective study, the 400 medical record sheets of the patients from two teaching hospitals affiliated to Jahrom medical university was randomly selected. The tool of data collection was a checklist based on the content of medical history sheet, operation report and physician order sheets. The data were analyzed by SPSS (Version10 software and Microsoft Office Excel 2003. Results: Average of personal (Demography data entered in medical history, physician order and operation report sheets which is done by department's secretaries were 32.9, 35.8 and 40.18 percent. Average of clinical data entered by physician in medical history sheet is 38 percent. Surgical data entered by the surgeon in operation report sheet was 94.77 percent. Average of data entered by operation room's nurse in operation report sheet was 36.78 percent; Average of physician order data in physician order sheet entered by physician was 99.3 percent. Conclusion: According to this study, the rate of completed record papers reviewed by documentary in Jahrom teaching hospitals were not desirable and in some cases were very weak and incomplete. This deficiency was due to different reason such as medical record documentaries negligence, lack of adequate education for documentaries, High work

  8. Final environmental impact statement. Proton--Proton Storage Accelerator Facility (ISABELLE), Brookhaven National Laboratory, Upton, New York

    International Nuclear Information System (INIS)

    1978-08-01

    An Environmental Impact Statement for a proposed research facility (ISABELLE) to be built at Brookhaven National Laboratory (BNL) is presented. It was prepared by the Department of Energy (DOE) following guidelines issued for such analyses. In keeping with DOE policy, this statement presents a concise and issues-oriented analysis of the significant environmental effects associated with the proposed action. ISABELLE is a proposed physics research facility where beams of protons collide providing opportunities to study high energy interactions. The facility would provide two interlaced storage ring proton accelerators, each with an energy up to 400 GeV intersecting in six experimental areas. The rings are contained in a tunnel with a circumference of 3.8 km (2.3 mi). The facility will occupy 250 ha (625 acres) in the NW corner of the existing BNL site. A draft Environmental Impact Statement for this proposed facility was issued for public review and comment by DOE on February 21, 1978. The principal areas of concern expressed were in the areas of radiological impacts and preservation of cultural values. After consideration of these comments, appropriate actions were taken and the text of the statement has been amended to reflect the comments. The text was annotated to indicate the origin of the comment. The Appendices contain a glossary of terms and listings of metric prefixes and conversions and symbols and abbreviations

  9. High intensity proton operation at the Brookhaven AGS accelerator complex

    International Nuclear Information System (INIS)

    Ahrens, L.A.; Blaskiewicz, M.; Bleser, E.; Brennan, J.M.; Gardner, C.; Glenn, J.W.; Onillon, E.; Reece, R.K.; Roser, T.; Soukas, A.

    1994-01-01

    With the completion of the AGS rf upgrade, and the implementation of a transition open-quotes jumpclose quotes, all of accelerator systems were in place in 1994 to allow acceleration of the proton intensity available from the AGS Booster injector to AGS extraction energy and delivery to the high energy users. Beam commissioning results with these new systems are presented. Progress in identifying and overcoming other obstacles to higher intensity are given. These include a careful exploration of the stopband strengths present on the AGS injection magnetic porch, and implementation of the AGS single bunch transverse dampers throughout the acceleration cycle

  10. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Analysis of core damage frequency from internal events during mid-loop operations, Main report (Chapters 1--6). Volume 2, Part 1A

    International Nuclear Information System (INIS)

    Chu, T.L.; Musicki, Z.; Kohut, P.

    1992-06-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this report is to document the approach utilized in the Surry plant and discuss the results obtained. A parallel report for the Grand Gulf plant is prepared by SNL. This study shows that the core-damage frequency during mid-loop operation at the Surry plant is comparable to that of power operation. We recognize that there is very large uncertainty in the human error probabilities in this study. This study identified that only a few procedures are available for mitigating accidents that may occur during shutdown written specifically for shutdown accidents would be useful. This document presents Chapters 1--6 of the report

  11. Mosquito and Fly Surveillance and Control Research at the USDA-ARS Center for Medical, Agricultural and Veterinary Entomology: Solving Operational Challenges

    Science.gov (United States)

    The Mosquito and Fly Research Unit of the USDA-ARS Center for Medical, Agricultural and Veterinary Entomology located in Gainesville Florida is the largest Federal laboratory devoted to specifically solving operational mosquito and fly surveillance and control challenges in the U.S. and internationa...

  12. Integrated Medical Model Overview

    Science.gov (United States)

    Myers, J.; Boley, L.; Foy, M.; Goodenow, D.; Griffin, D.; Keenan, A.; Kerstman, E.; Melton, S.; McGuire, K.; Saile, L.; hide

    2015-01-01

    The Integrated Medical Model (IMM) Project represents one aspect of NASA's Human Research Program (HRP) to quantitatively assess medical risks to astronauts for existing operational missions as well as missions associated with future exploration and commercial space flight ventures. The IMM takes a probabilistic approach to assessing the likelihood and specific outcomes of one hundred medical conditions within the envelope of accepted space flight standards of care over a selectable range of mission capabilities. A specially developed Integrated Medical Evidence Database (iMED) maintains evidence-based, organizational knowledge across a variety of data sources. Since becoming operational in 2011, version 3.0 of the IMM, the supporting iMED, and the expertise of the IMM project team have contributed to a wide range of decision and informational processes for the space medical and human research community. This presentation provides an overview of the IMM conceptual architecture and range of application through examples of actual space flight community questions posed to the IMM project.

  13. STS-3 medical report

    Science.gov (United States)

    Pool, S. L. (Editor); Johnson, P. C., Jr. (Editor); Mason, J. A. (Editor)

    1982-01-01

    The medical operations report for STS-3, which includes a review of the health of the crew before, during, and immediately after the third Shuttle orbital flight is presented. Areas reviewed include: health evaluation, medical debriefing of crewmembers, health stabilization program, medical training, medical 'kit' carried in flight, tests and countermeasures for space motion sickness, cardiovascular profile, biochemistry and endocrinology results, hematology and immunology analyses, medical microbiology, food and nutrition, potable water, shuttle toxicology, radiological health, and cabin acoustic noise. Environmental effects of shuttle launch and landing medical information management, and management, planning, and implementation of the medical program are also dicussed.

  14. 10 CFR 55.21 - Medical examination.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Medical examination. 55.21 Section 55.21 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) OPERATORS' LICENSES Medical Requirements § 55.21 Medical examination. An applicant for a license shall have a medical examination by a physician. A licensee shall have a medical...

  15. An analysis of operational experience during low power and shutdown and a plan for addressing human reliability assessment issues

    International Nuclear Information System (INIS)

    Barriere, M.; Luckas, W.; Whitehead, D.; Ramey-Smith, A.

    1994-06-01

    Recent nuclear power plant events (e.g. Chernobyl, Diablo Canyon, and Vogtle) and US Nuclear Regulatory Commission (NRC) reports (e.g. NUREG-1449) have led to concerns regarding human reliability during low power and shutdown (LP ampersand S) conditions and limitations of human reliability analysis (HRA) methodologies in adequately representing the LP ampersand S environment. As a result of these concerns, the NRC initiated two parallel research projects to assess the influence of LP ampersand S conditions on human reliability through an analysis of operational experience at pressurized water reactors (PWRs) an boiling water reactors (BWRs). These research projects, performed by Brookhaven National Laboratory for PWRS, and Sandia National Laboratories for BWRs, identified unique aspects of human performance during LP ampersand S conditions and provided a program plan for research and development necessary to improve existing HRA methodologies. This report documents the results of the analysis of LP ampersand S operating experience and describes the improved HRA program plan

  16. [New possibilities in emergency medical transportation and emergency services of Polish Medical Air Rescue].

    Science.gov (United States)

    Gałazkowski, Robert

    2010-01-01

    In Poland, two types of medical services are accomplished by the Medical Air Rescue (MAR) operating all over the country: emergency transport from the incident scene to hospital and inter-hospital transport. Helicopters or planes are used for this purpose. In 2009, helicopters performed 4359 flights to incidents and 1537 inter-hospital transports whereas planes performed 589 inter-hospital ambulance and 196 rescue flights. MAR operates from 17 bases of the Helicopter Emergency Medical Service (HEMS) and one airbase. Helicopters are mainly used when medical transport is emergent, within the operational region of a given base whereas planes when the distance between the present and target airports exceeds 250 km. In 2008, new modern aircraft were introduced to HEMS-helicopters EC 135. They fulfil all requirements of air transport regulations and are adjusted to visual (VFR) and instrumental (IFR) flights rules, at day and night. The medical cabin of EC 135 is ergonomic and functional considering the majority of rescue activities under life-saving circumstances. It is equipped with ventilator, defibrillator, infusion pumps etc. Defibrillators have 12-lead ECG, E(T)CO2, SpO2, NIBP, and IBP modules. Transport ventilators can work in a variety of ventilation modes including CMV, SIMV, SVV, BILEVEL, PCV, ASB, PPV and CPAP. The purchase of helicopters with modern avionic and medical configuration ensures high quality services of MAR for many years to come.

  17. The text of the Agreement establishing the Asian Regional Co-operative Project on Medical and Biological Applications of Nuclear Techniques

    International Nuclear Information System (INIS)

    1987-04-01

    The full text of the Agreement establishing the Asian Regional Co-operative Project on Medical and Biological Applications of Nuclear Techniques between the Agency and Member States is reproduced. The Agreement entered into force on 20 May 1986 after the Governments of Japan, Bangladesh and the Philippines had notified the Agency of their acceptance of the Agreement

  18. Medical Applications

    OpenAIRE

    Biscari, C.; Falbo, L.

    2016-01-01

    The use of accelerators for medical applications has evolved from initial experimentation to turn-key devices commonly operating in hospitals. New applications are continuously being developed around the world, and the hadrontherapy facilities of the newest generation are placed at the frontier between industrial production and advanced R&D. An introduction to the different medical application accelerators is followed by a description of the hadrontherapy facilities, with special emphasis on ...

  19. Operation of general purpose stepping motor controllers at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Stubblefield, F.W.

    1987-01-01

    A prototype and four copies of a general purpose subsystem for mechanical positioning of detectors, samples, and beam line optical elements which constitute experiments at the National Synchrotron Light Source facility of Brookhaven National Laboratory have been constructed and placed into operation. Construction of a sixth subsystem is nearing completion. The subsystems effect mechanical positioning by controlling a set of stepping motors and their associated position encoders. The units are general purpose in the sense that they receive commands over a standard 9600 baud asynchronous serial line compatible with the RS-232-C electrical signal standard, generate TTL-compatible streams of stepping pulses which can be used with a wide variety of stepping motors, and read back position values from a number of different types and models of position encoder. The basic structure of the motor controller subsystem is briefly reviewed. Short descriptions of the positioning apparatus actuated at each of the test and experiment stations employing a motor control unit are given. Additions and enhancements to the sub-system made in response to problems indicated by actual operation of the four installed units are described in more detail

  20. Operation of general purpose stepping motor controllers at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Stubblefield, F.W.

    1986-10-01

    A prototype and four copies of a general purpose subsystem for mechanical positioning of detectors, samples, and beam line optical elements which constitute experiments at the National Synchrotron Light Source facility of Brookhaven National Laboratory have been constructed and placed into operation. Construction of a sixth subsystem is nearing completion. The subsystems effect mechanical positioning by controlling a set of stepping motors and their associated position encoders. The units are general purpose in the sense that they receive commands over a standard 9600 baud asynchronous serial line compatible with the RS-232-C electrical signal standard, generate TTL-compatible streams of stepping pulses which can be used with a wide variety of stepping motors, and read back position values from a number of different types and models of position encoder. The basic structure of the motor controller subsystem will be briefly reviewed. Short descriptions of the positioning apparatus actuated at each of the test and experiment stations employing a motor control unit are given. Additions and enhancements to the subsystem made in response to problems indicated by actual operation of the four installed units are described in more detail

  1. Converting Radiology Operations in a Six-Hospital Healthcare System from Film-Based to Digital: Another Leadership Role for the Diagnostic Medical Physicist

    International Nuclear Information System (INIS)

    Arreola, Manuel M.; Rill, Lynn N.

    2004-01-01

    As medical facilities across the United States continue to convert their radiology operations from film-based to digital environments, partially accomplished and failed endeavors are frequent because of the lack of competent and knowledgeable leadership. The diagnostic medical physicist is, without a doubt, in a privileged position to take such a leadership role, not only because of her/his understanding of the basics principles of new imaging modalities, but also because of her/his inherent participation in workflow design and educational/training activities. A well-structured approach by the physicist will certainly lead the project to a successful completion, opening, in turn, new opportunities for the medical physicist to become an active participant in the decision-making process for an institution

  2. Converting Radiology Operations in a Six-Hospital Healthcare System from Film-Based to Digital: Another Leadership Role for the Diagnostic Medical Physicist

    Science.gov (United States)

    Arreola, Manuel M.; Rill, Lynn N.

    2004-09-01

    As medical facilities across the United States continue to convert their radiology operations from film-based to digital environments, partially accomplished and failed endeavors are frequent because of the lack of competent and knowledgeable leadership. The diagnostic medical physicist is, without a doubt, in a privileged position to take such a leadership role, not only because of her/his understanding of the basics principles of new imaging modalities, but also because of her/his inherent participation in workflow design and educational/training activities. A well-structured approach by the physicist will certainly lead the project to a successful completion, opening, in turn, new opportunities for the medical physicist to become an active participant in the decision-making process for an institution.

  3. Medical Simulations for Exploration Medicine

    Science.gov (United States)

    Reyes, David; Suresh, Rahul; Pavela, James; Urbina, Michelle; Mindock, Jennifer; Antonsen, Erik

    2018-01-01

    Medical simulation is a useful tool that can be used to train personnel, develop medical processes, and assist cross-disciplinary communication. Medical simulations have been used in the past at NASA for these purposes, however they are usually created ad hoc. A stepwise approach to scenario development has not previously been used. The NASA Exploration Medical Capability (ExMC) created a medical scenario development tool to test medical procedures, technologies, concepts of operation and for use in systems engineering (SE) processes.

  4. Effects of Stimulant Medication under Varied Motivational Operations

    Science.gov (United States)

    Mace, F. Charles; Prager, Kevin L.; Thomas, Karen; Kochy, Jane; Dyer, Tim J.; Perry, Lora; Pritchard, Duncan

    2009-01-01

    We evaluated the evocative effects of four conditions (high- and low-preference activities, low and divided attention) and stimulant medication on the behavior of a 16-year-old boy with attention deficit hyperactivity disorder and moderate mental retardation. All behavior (activity engagement, activity changes, inappropriate touching, rude…

  5. Important radiation protection aspects of the operation of a commercial medical cyclotron

    International Nuclear Information System (INIS)

    Mukherjee, B.

    1997-01-01

    Since July 1991 the Radiopharmaceutical Division of the Australian Nuclear Science and Technology Organisation (ANSTO) operates a 30 MeV H'- ion Medical Cyclotron (Model; CYCLONE 30, Manufacturer: Ion Beam Applications, Louvain La Neuve, Belgium). During routine isotope production operations at the cyclotron a thick copper substrate plate electroplated with thin layer of selected enriched target material are bombarded with 30 MeV proton beam current up to 450 μA. The nuclear reaction of protons with the copper atoms result in the reduction of prompt evaporation neutrons with a peak energy of ∼ 1.8 MeV. These evaporation neutrons slow down via multiple collisions with the concrete shielding walls of the target cave, bounce back to the,interior space of the cave activating the cyclotron parts, beam tube components and other utilities installed in the irradiation cave. After the completion of 60 hour isotope production run, gamma dose equivalent rates of ∼10 5 μSvh -1 were measured at contact with the target irradiation stations and beam collimators. Evidently, these gamma rays emitted from the activated cyclotron components impose crucial radiation exposure hazard problems for the cyclotron maintenance technicians. Experiments had been carried out in order to identify the specific pathways of cyclotron component activation and to assess the probable personnel radiation exposure during handling of the activated cyclotron parts. The cool-down (radioactive decay) of the activated cyclotron components was estimated experimentally at different target bombardment conditions using the wall mounted gamma area monitors interfaced to the Health Physics Data Acquisition System. The gamma dose equivalent rates at contact with various locations of interest at the target irradiation station and at the typical work areas of the maintenance personnel were carefully recorded with a radiation (gamma) survey instrument during the three years operation period of the cyclotron. A

  6. Radiation protection in the operating room

    International Nuclear Information System (INIS)

    Kunz, B.; Stargardt, A.

    1978-01-01

    On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low

  7. Safety significance of inadvertent operation of motor-operated valves in nuclear power plants

    International Nuclear Information System (INIS)

    Ruger, C.J.; Higgins, J.C.; Carbonaro, J.F.; Hall, R.E.

    1994-01-01

    Concerns about the consequences of valve mispositioning were brought to the forefront following an event at Davis Besse in 1985. The concern related to the ability to reposition open-quotes position-changeableclose quotes motor-operated valves (MOVs) from the control room in the event of their inadvertent operation and was documented in U.S. Nuclear Regulatory Commission (USNRC) Bulletin 85-03 and Generic Letter (GL) 89-10. The mispositioned MOVs may not be able to be returned to their required position due to high differential pressure or high flow conditions across the valves. The inability to reposition such valves may have significantly safety consequences, as in the Davis Besse event. However, full consideration of such mispositioning in safety analyses and in MOV test programs can be labor intensive and expensive. Industry raised concerns that consideration of position-changeable valves under GL 89-10 would not decrease the probability of core damage to an extent that would justify licensee costs. As a response, Brookhaven National Laboratory has conducted separate scoping studies for both boiling water reactors (BWRs) and pressurized water reactors (PWRs) using probabilistic risk assessment (PRA) techniques to determine if such valve mispositioning by itself is significant to safety. The approach used internal events PRA models to survey the order of magnitude of the risk-significance of valve mispositioning by considering the failure of selected position-changeable MOVs. The change in core damage frequency was determined for each valve considered, and the results were presented as a risk increase ratio for each of four assumed MOV failure rates. The risk increase ratios resulting from this failure rate sensitivity study can be used as a basis for a determination of the risk-significance of the MOV mispositioning issues for BWRs and PWRs

  8. Human Factors and Medical Devices

    International Nuclear Information System (INIS)

    Dick Sawyer

    1998-01-01

    Medical device hardware- and software-driven user interfaces should be designed to minimize the likelihood of use-related errors and their consequences. The role of design-induced errors in medical device incidents is attracting widespread attention. The U.S. Food and Drug Administration (FDA) is fully cognizant that human factors engineering is critical to the design of safe medical devices, and user interface design is receiving substantial attention by the agency. Companies are paying more attention to the impact of device design, including user instructions, upon the performance of those health professionals and lay users who operate medical devices. Concurrently, the FDA is monitoring human factors issues in its site inspections, premarket device approvals, and postmarket incident evaluations. Overall, the outlook for improved designs and safer device operation is bright

  9. Use of the NASA Space Radiation Laboratory at Brookhaven National Laboratory to Conduct Charged Particle Radiobiology Studies Relevant to Ion Therapy.

    Science.gov (United States)

    Held, Kathryn D; Blakely, Eleanor A; Story, Michael D; Lowenstein, Derek I

    2016-06-01

    Although clinical studies with carbon ions have been conducted successfully in Japan and Europe, the limited radiobiological information about charged particles that are heavier than protons remains a significant impediment to exploiting the full potential of particle therapy. There is growing interest in the U.S. to build a cancer treatment facility that utilizes charged particles heavier than protons. Therefore, it is essential that additional radiobiological knowledge be obtained using state-of-the-art technologies and biological models and end points relevant to clinical outcome. Currently, most such ion radiotherapy-related research is being conducted outside the U.S. This article addresses the substantial contributions to that research that are possible at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL), which is the only facility in the U.S. at this time where heavy-ion radiobiology research with the ion species and energies of interest for therapy can be done. Here, we briefly discuss the relevant facilities at NSRL and how selected charged particle biology research gaps could be addressed using those facilities.

  10. In-flight medical emergencies during airline operations: a survey of physicians on the incidence, nature, and available medical equipment

    Directory of Open Access Journals (Sweden)

    Hinkelbein J

    2017-02-01

    Full Text Available Jochen Hinkelbein,1,2 Christopher Neuhaus,2,3 Lennert Böhm,1 Steffen Kalina,1 Stefan Braunecker1,2 1Department of Anaesthesiology and Intensive Care Medicine, University Hospital of Cologne, Cologne, 2Working group “Emergency Medicine and Air Rescue”, German Society for Aviation and Space Medicine (DGLRM, Munich, 3Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany Background: Data on the incidence of in-flight medical emergencies on-board civil aircraft are uncommon and rarely published. Such data could provide information regarding required medical equipment on-board aircraft and requisite training for cabin crew. The aim of the present study was to gather data on the incidences, nature, and medical equipment for in-flight medical emergencies by way of a survey of physician members of a German aerospace medical society.Materials and methods: Using unipark.de (QuestBack GmbH, Cologne, Germany, an online survey was developed and used to gather specific information. Members of the German Society for Aviation and Space Medicine (Deutsche Gesellschaft für Luft- und Raumfahrtmedizin e.V.; DGLRM were invited to participate in the survey during a 4-week period (21 March 2015 to 20 April 2015. Chi-square test was used for statistical analysis (p<0.05 was considered significant.Results: Altogether, 121 members of the society responded to the survey (n=335 sent out. Of the 121 respondents, n=54 (44.6% of the participants (89.9% male and 10.1% female; mean age, 54.1 years; n=121 were involved in at least one in-flight medical emergency. Demographic parameters in this survey were in concordance with the society members’ demographics. The mean duration of flights was 5.7 hours and the respondents performed 7.1 airline flights per year (median. Cardiovascular (40.0% and neurological disorders (17.8% were the most frequent diagnoses. The medical equipment (78.7% provided was sufficient. An emergency diversion was

  11. Aeromedical Hazard Comparison of FAA Medically Certified Third-Class and Medically Uncertified Pilots.

    Science.gov (United States)

    Ricaurte, Eduard M; Mills, William D; DeJohn, Charles A; Laverde-Lopez, Maria C; Porras-Sanchez, Daniel F

    2016-07-01

    Since 2004, in the United States, light sport aircraft (LSA) and some aircraft with standard airworthiness certificates can be operated for recreational purposes with a valid state driver's license rather than a Federal Aviation Administration (FAA)-issued aeromedical certificate. There have been recent efforts to allow operation of much larger, heavier, faster, and more complex aircraft without requiring a medical certificate. The primary objective of this research was to compare hazards to flight safety identified in fatally injured pilots required to possess a valid FAA third-class medical certificate to hazards in fatally injured pilots who were not required to possess a valid medical certificate. A search of all fatal U.S. aircraft accidents in the FAA Medical ANalysis and TRAcking (MANTRA) registry between January 1, 2011, and April 30, 2014, identified 1084 individuals. A review of accident pilots' medical, autopsy, and toxicological data was conducted. After applying exclusion criteria, 467 pilots remained, including 403 medically certified and 64 medically uncertified pilots. A significant difference was found in a surrogate measure for risk between medically certified and uncertified pilots (25% vs. 59%). This difference remained significant after adjustment for age. No significant difference was found in the proportions of hazards identified on toxicological review. The results of this study suggest that the risk of an adverse medical event is reduced in pilots required to possess a valid medical certificate. Ricaurte EM, Mills WD, DeJohn CA, Laverde-Lopez MC, Porras-Sanchez DF. Aeromedical hazard comparison of FAA medically certified third-class and medically uncertified pilots. Aerosp Med Hum Perform. 2016; 87(7):618-621.

  12. Medical results of the Skylab program

    Science.gov (United States)

    Johnston, R. S.; Dietlein, L. F.

    1974-01-01

    The Skylab food system, waste management system, operational bioinstrumentation, personal hygiene provisions, in-flight medical support system, and the cardiovascular counterpressure garment worn during reentry are described. The medical experiments program provided scientific data and also served as the basis for real-time decisions on flight duration. Premission support, in-flight operational support, and postflight medical activities are surveyed. Measures devised to deal with possible food spoilage, medical instrument damage, and toxic atmosphere caused by the initial failures on the Orbital Workshop (OWS) are discussed. The major medical experiments performed in flight allowed the study of physiological changes as a function of exposure to weightless flight. The experiments included studies of the cardiovascular system, musculoskeletal and fluid/electrolyte balance, sleep, blood, vestibular system, and time and motion studies.

  13. Medical Information Technology in Support of the Operational Commander

    National Research Council Canada - National Science Library

    Mitchell, James

    1999-01-01

    .... DoD is aggressively pursuing a unified force health protection strategy to protect service members from medical hazards associated with their military service from accession through retirement...

  14. Exploration Medical Cap Ability System Engineering Overview

    Science.gov (United States)

    McGuire, K.; Mindock, J.

    2018-01-01

    Deep Space Gateway and Transport missions will change the way NASA currently practices medicine. The missions will require more autonomous capability compared to current low Earth orbit operations. For the medical system, lack of consumable resupply, evacuation opportunities, and real-time ground support are key drivers toward greater autonomy. Recognition of the limited mission and vehicle resources available to carry out exploration missions motivates the Exploration Medical Capability (ExMC) Element's approach to enabling the necessary autonomy. The ExMC Systems Engineering team's mission is to "Define, develop, validate, and manage the technical system design needed to implement exploration medical capabilities for Mars and test the design in a progression of proving grounds." The Element's work must integrate with the overall exploration mission and vehicle design efforts to successfully provide exploration medical capabilities. ExMC is using Model-Based System Engineering (MBSE) to accomplish its integrative goals. The MBSE approach to medical system design offers a paradigm shift toward greater integration between vehicle and the medical system, and directly supports the transition of Earth-reliant ISS operations to the Earth-independent operations envisioned for Mars. This talk will discuss how ExMC is using MBSE to define operational needs, decompose requirements and architecture, and identify medical capabilities needed to support human exploration. How MBSE is being used to integrate across disciplines and NASA Centers will also be described. The medical system being discussed in this talk is one system within larger habitat systems. Data generated within the medical system will be inputs to other systems and vice versa. This talk will also describe the next steps in model development that include: modeling the different systems that comprise the larger system and interact with the medical system, understanding how the various systems work together, and

  15. Operational measurements in radioprotection in the industrial and medical environments; Mesures operationnelles en radioprotection dans les milieux industriel et medical

    Energy Technology Data Exchange (ETDEWEB)

    Rodde, S.; Vial, Th.; Truffert, H.; Kramar, R.; Batalla, A.; Roine, Ph.; Pin, A.; Lahaye, Th.; Rodde, S.; Bordy, J.M.; Paquet, F.; Veres, A.; Cadiou, A.; Branthonne, J.Y.; Noel, A.; Laloubere, L.; Moreau, St.; Gensdarmes, F.; Marques, S.; Lestang, M.; Valendru, N.; Tranchant, Ph.; Martel, P.; Bernhard, S.; Chareyre, P.; Gardin, I.; Casanova, Ph.; De Vita, A.; Tenailleau, L.; Masson, B.; Feret, B.; Guerin, M.; Guillot, L.; Gaultier, E.

    2009-07-01

    This document gathers the slides of the available presentations given during these conference days. Thirty presentations are assembled in the document and deal with: 1 - enforcement circular of the labor code dispositions relative to workers protection against ionizing radiation hazards (T. Lahaye); 2 - context and regulatory evolutions - public health code (S. Rodde); 3 - references and perspectives in external dosimetry (J.M. Bordy); 4 - CIPR's Committee 2 works (F. Paquet); 5 - from protection data to measurement data (A. Pin); 6 - dosimetric control in radiotherapy (A. Veres); 7 - calibration of irradiation measurement devices in industrial environment (A. Cadiou); 8 - calibration and verification of nuclear measurement devices (J.Y. Branthonne); 9 - calibration of measurement devices in medical environment (J.M. Bordy); 10 - quality control in radiotherapy (A. Batalla); 11 - in-vivo dosimetry in radiotherapy (A. Noel); 12 - calibration metrology of fixed post irradiation sensors (L. Laloubere); 13 - design requirements for the radiological zoning and the wastes cleanliness of Flamanville 3 EPR reactor (S. Moreau); 14 - efficiency of aerosol capture systems used in CNPE EDF (F. Gensdarmes); 15 - mobile surveillance means of the atmospheric contamination of CNPE EDF's reactor building (S. Marques and M. Lestang); 16 - experience feedback about the security gates at EDF's nuclear facilities (N. Valendru); 17 - metrology needs for radioprotection technical controls (P. Tranchant); 18 - technical evaluation of a flowmeter/dosemeter in the framework of the regulatory control of X-ray electric generators used in radio-diagnosis (P. Martel); 19 - reinforced natural radioactivity - the case of radon measurement (S. Bernhard); 20 - fires during radioactive materials transport (P. Chareyre); 21 - measurement in the framework of medical examinations: radiology service (A. Noel); 22 - operational measurements in nuclear medicine (I. Gardin); 23 - from the

  16. Linear accelerator development at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Batchelor, K.

    1976-01-01

    A description is given of operating experience on the 200 MeV Proton Injector Linace of the A.G.S. emphasizing developments in field phase and amplitude control and beam diagnostics. Developments in auxilliary use of the machine are also described

  17. Linear accelerator development at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Batchelor, K.

    1976-01-01

    This paper describes the operating experience on the 200 MeV proton injector linac of the A.G.S. emphasizing developments in field phase and amplitude control and beam diagnostics. Developments in auxilliary use of the machine are also described. (author)

  18. Development of an x-ray fluorescence microprobe at the National Synchrotron Light Source, Brookhaven National Laboratory: Early results: Comparison with data from other techniques

    International Nuclear Information System (INIS)

    Smith, J.V.; Rivers, M.L.; Sutton, S.R.; Jones, K.W.; Hanson, A.L.; Gordon, B.M.

    1986-01-01

    Theoretical predictions for the detection levels in x-ray fluorescence analysis with a synchrotron storage ring are being achieved experimentally at several laboratories. This paper is deliberately restricted to the state of development of the Brookhaven National Laboratory/University of Chicago instruments. Analyses at the parts per million (ppM) level are being made using white light apertured to 20 μm and an energy dispersive system. This system is particularly useful for elements with Z > 20 in materials dominated by elements with Z < 20. Diffraction causes an interference for crystalline materials. Development of a focusing microprobe for tunable monochromatic x-rays and a wavelength dispersive spectrometer (WDS) is delayed by problems in shaping an 8:1 focusing mirror to the required accuracy. Reconnaissance analyses with a wiggler source on the CHESS synchrotron have been made in the K spectrum up to Z = 80

  19. Guide of good practices in medical physics - French Society of Medical Physics

    International Nuclear Information System (INIS)

    Rosenwald, Jean-Claude; Aventin, Christophe; Coste, Frederic; Francois, Pascal; Ginestet, Chantal; Perrin, Benedicte; Salvat, Cecile; Caselles, Olivier; Dedieu, Veronique; Dejean, Catherine; Batalla, Alain; Guillaume, Bonniaud; Le Du, Dominique; Lisbona, Albert; Marchesi, Vincent; Sarrazin, Thierry; Mazeron, Jean-Jacques; Lipinski, Francis; Vera, Pierre; Vermandel, Maximilien; Ducou le Pointe, Hubert; Vidal, Vincent; Henry, Cecile; Mazeau-Woynar, Valerie; Prot, Camille; Valero, Marc; Aubert, Bernard; Etard, Cecile; Jimonet, Christine; Roue, Amelie; Sage, Julie; Bardies, Manuel; Beauvais, Helene; Bey, Pierre; Costa, Andre; Desblancs, Claire; Eudaldo, Teresa; Farman, Bardia; Ferrand, Regis; Garcia, Robin; Giraud, Jean-Yves; Husson, Francois; Koulibaly, Malick; Carlan, Loic de; Manens, Jean-Pierre; Naudy, Suzanne; Noel, Alain; Pilette, Pierre; Verdun, Francis; Bouette, Aurelien; Breen, Stephen; Bridier, Andre; Chauvenet, Bruno; Chavaudra, Jean; Gardin, Isabelle; Herlevin, Karine

    2012-01-01

    After a presentation of the methodological approach used to write this book, the first chapter addresses the profession of medical physicist: medical physics in France (history, evolution of the profession, of the education and of regulation), legal framework (related to the medical use of ionizing radiations, legal texts directly concerning medical physics, regulations impacting the professional practice of medical physicists), scopes of intervention of the medical physicist (context, missions, dose management, image quality, quality management and safety, relationship with the patient, education, training and research, relationships with industry, cost management), operating conditions, and good professional practices. The second chapter addresses the principles of management of quality and safety: quality management in medical physics, safety management, quality and safety in health care facilities. The third part addresses good practices in medical physics: general principles of working methods, equipment management, participation to clinic activities

  20. The sound of operation and the acoustic attenuation of the Ohmeda Medical Giraffe OmniBed™.

    Science.gov (United States)

    Wubben, Stephanie M; Brueggeman, Paul M; Stevens, Dennis C; Helseth, Carol C; Blaschke, Kristen

    2011-01-01

    The neonatal intensive care unit (NICU) is an environment that provides premature and fragile infants with health provisions needed to make a complete recovery. Premature infants are often born before their auditory systems have had an opportunity to fully mature. Research has shown that the ambient acoustic environment in the NICU exceeds the maximum noise level recommended by the American Academy of Pediatrics, even after measures have been taken to decrease noise levels. The purpose of this study is to evaluate noise levels inside an Ohmeda Medical Giraffe™ OmniBed™, the natural attenuation of the incubator, and the effects of modifications on attenuation and reverberation within the Giraffe TM OmniBed™. The normal operation of the Giraffe™ OmniBed™ is 41.7 dBA which indicates a lower noise of operation than previous studies. The Giraffe™ OmniBed™ naturally attenuates 12 dBA. Leaving an access latch or portal door open causes a statistically significant (P=.001) increase in sound within the bassinet. All modifications in the no-noise and the noise conditions showed a statistically significant (P=.001) drop in L(eq) when compared to baseline.

  1. Quality assurance in medical radiation applications. The medical and dental appointment

    International Nuclear Information System (INIS)

    Ernst-Elz, Andreas

    2017-01-01

    Medical radiation applications cause averaged over the German population an annual exposure of almost 2 mSv. Medical authorities have the assignment to assure and control the diagnostic and therapeutic quality of these applications and to provide recommendations for operators with respect to dose reductions and radiation protection, including guidance for radiotherapy planning aimed to questions of dose and therapy optimization.

  2. The medical story. [of Skylab

    Science.gov (United States)

    Johnston, R. S.; Dietlein, L. F.; Michel, E. L.

    1975-01-01

    The paper discusses the medical program of the Skylab missions. The major medical systems discussed include the food system, the waste-management system, the personal-hygiene system, and the inflight medical support system. The life-sciences experiments conducted on Skylab are reviewed. These dealt with the cardiovascular system, mineral balance and bioassay of fluids, sleep, blood, metabolic activity, vestibular function, and time and motion studies. The medical operations were accomplished with only minor problems.

  3. Medical Data Architecture Project Status

    Science.gov (United States)

    Krihak, M.; Middour, C.; Lindsey, A.; Marker, N.; Wolfe, S.; Winther, S.; Ronzano, K.; Bolles, D.; Toscano, W.; Shaw, T.

    2017-01-01

    The Medical Data Architecture (MDA) project supports the Exploration Medical Capability (ExMC) risk to minimize or reduce the risk of adverse health outcomes and decrements in performance due to in-flight medical capabilities on human exploration missions. To mitigate this risk, the ExMC MDA project addresses the technical limitations identified in ExMC Gap Med 07: We do not have the capability to comprehensively process medically-relevant information to support medical operations during exploration missions. This gap identifies that the current International Space Station (ISS) medical data management includes a combination of data collection and distribution methods that are minimally integrated with on-board medical devices and systems. Furthermore, there are variety of data sources and methods of data collection. For an exploration mission, the seamless management of such data will enable an increasingly autonomous crew than the current ISS paradigm. The MDA will develop capabilities that support automated data collection, and the necessary functionality and challenges in executing a self-contained medical system that approaches crew health care delivery without assistance from ground support. To attain this goal, the first year of the MDA project focused on reducing technical risk, developing documentation and instituting iterative development processes that established the basis for the first version of MDA software (or Test Bed 1). Test Bed 1 is based on a nominal operations scenario authored by the ExMC Element Scientist. This narrative was decomposed into a Concept of Operations that formed the basis for Test Bed 1 requirements. These requirements were successfully vetted through the MDA Test Bed 1 System Requirements Review, which permitted the MDA project to begin software code development and component integration. This paper highlights the MDA objectives, development processes, and accomplishments, and identifies the fiscal year 2017 milestones and

  4. Tritium toxicity program in the Medical Department at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Carsten, A.L.

    1985-01-01

    A summary of all the findings to date is given. It appears from this information that it is possible to detect somatic, cytogenetic, and genetic effects resulting from exposures at 33 to 100 times the mpc's for HTO. Similar effects also result from exposure to external gamma rays at an equivalent dose. The reduction in bone marrow cells in animals maintaining normal total cellularity is of interest since it demonstrates both the presence of an effect at the primitive cell level and the animal's ability to compensate for this effect by recruiting stem cells from the G0 resting state. This evidence of damage together with the observed cytogenetic changes leads one to contemplate the possible importance of radiation exposures at these levels for the induction of leukemia or other blood dyscrasias. Studies to investigate this question are now under way. As predicted on the basis of established principles of radiobiology, exposure to tritium beta rays from HTO ingestion results in measurable effects on several animal systems. The importance of position of incorporation of H into molecules of biological importance has not been well defined, nor have the low-dose portions of the dose-response curve for several effects of interest. Experiments designed to address these questions and measure H turnover as a means for analysis of cell kinetics in several systems are now under way

  5. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Evaluation of severe accident risk during mid-loop operations. Main report. Volume 6. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Jo, J.; Lin, C.C.; Neymotin, L. [Brookhaven National Lab., Upton, NY (United States)] [and others

    1995-05-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program includes that of a level-3 PRA. A phased approach was used in the level-1 program. In phase 1 which was completed in Fall 1991, a coarse screening analysis including internal fire and flood was performed for all plant operational states (POSs). The objective of the phase 1 study was to identify potential vulnerable plant configurations, to characterize (on a high, medium, or low basis) the potential core damage accident scenarios, and to provide a foundation for a detailed phase 2 analysis. In phase 2, mid-loop operation was selected as the plant configuration to be analyzed based on the results of the phase 1 study. The objective of the phase 2 study is to perform a detailed analysis of the potential accident scenarios that may occur during mid-loop operation, and compare the results with those of NUREG-1150. The results of the phase 2 level 2/3 study are the subject of this volume of NUREG/CR-6144, Volume 6.

  6. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit 1: Evaluation of severe accident risk during mid-loop operations. Main report. Volume 6. Part 1

    International Nuclear Information System (INIS)

    Jo, J.; Lin, C.C.; Neymotin, L.

    1995-05-01

    During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Laboratory (BNL) and Sandia National Laboratories (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program includes that of a level-3 PRA. A phased approach was used in the level-1 program. In phase 1 which was completed in Fall 1991, a coarse screening analysis including internal fire and flood was performed for all plant operational states (POSs). The objective of the phase 1 study was to identify potential vulnerable plant configurations, to characterize (on a high, medium, or low basis) the potential core damage accident scenarios, and to provide a foundation for a detailed phase 2 analysis. In phase 2, mid-loop operation was selected as the plant configuration to be analyzed based on the results of the phase 1 study. The objective of the phase 2 study is to perform a detailed analysis of the potential accident scenarios that may occur during mid-loop operation, and compare the results with those of NUREG-1150. The results of the phase 2 level 2/3 study are the subject of this volume of NUREG/CR-6144, Volume 6

  7. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit-1: Analysis of core damage frequency from internal events during mid-loop operations. Appendix I, Volume 2, Part 5

    Energy Technology Data Exchange (ETDEWEB)

    Chu, T.L.; Musicki, Z.; Kohut, P.; Yang, J.; Bozoki, G.; Hsu, C.J.; Diamond, D.J. [Brookhaven National Lab., Upton, NY (United States); Bley, D.; Johnson, D. [PLG Inc., Newport Beach, CA (United States); Holmes, B. [AEA Technology, Dorset (United Kingdom)] [and others

    1994-06-01

    Traditionally, probabilistic risk assessments (PRA) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Some previous screening analyses that were performed for other modes of operation suggested that risks during those modes were small relative to full power operation. However, more recent studies and operational experience have implied that accidents during low power and shutdown could be significant contributors to risk. During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Lab. (BNL) and Sandia National Labs. (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this volume of the report is to document the approach utilized in the level-1 internal events PRA for the Surry plant, and discuss the results obtained. A phased approach was used in the level-1 program. In phase 1, which was completed in Fall 1991, a coarse screening analysis examining accidents initiated by internal events (including internal fire and flood) was performed for all plant operational states (POSs). The objective of the phase 1 study was to identify potential vulnerable plant configurations, to characterize (on a high, medium, or low basis) the potential core damage accident scenarios, and to provide a foundation for a detailed phase 2 analysis.

  8. Evaluation of potential severe accidents during low power and shutdown operations at Surry, Unit-1: Analysis of core damage frequency from internal events during mid-loop operations. Appendix I, Volume 2, Part 5

    International Nuclear Information System (INIS)

    Chu, T.L.; Musicki, Z.; Kohut, P.; Yang, J.; Bozoki, G.; Hsu, C.J.; Diamond, D.J.; Bley, D.; Johnson, D.; Holmes, B.

    1994-06-01

    Traditionally, probabilistic risk assessments (PRA) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Some previous screening analyses that were performed for other modes of operation suggested that risks during those modes were small relative to full power operation. However, more recent studies and operational experience have implied that accidents during low power and shutdown could be significant contributors to risk. During 1989, the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. The program includes two parallel projects being performed by Brookhaven National Lab. (BNL) and Sandia National Labs. (SNL). Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The objectives of the program are to assess the risks of severe accidents initiated during plant operational states other than full power operation and to compare the estimated core damage frequencies, important accident sequences and other qualitative and quantitative results with those accidents initiated during full power operation as assessed in NUREG-1150. The objective of this volume of the report is to document the approach utilized in the level-1 internal events PRA for the Surry plant, and discuss the results obtained. A phased approach was used in the level-1 program. In phase 1, which was completed in Fall 1991, a coarse screening analysis examining accidents initiated by internal events (including internal fire and flood) was performed for all plant operational states (POSs). The objective of the phase 1 study was to identify potential vulnerable plant configurations, to characterize (on a high, medium, or low basis) the potential core damage accident scenarios, and to provide a foundation for a detailed phase 2 analysis

  9. 47 CFR 15.513 - Technical requirements for medical imaging systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Technical requirements for medical imaging... DEVICES Ultra-Wideband Operation § 15.513 Technical requirements for medical imaging systems. (a) The UWB... MHz and 10,600 MHz. (b) Operation under the provisions of this section is limited to medical imaging...

  10. Writing otorhinolaryngology head & neck surgery operative reports.

    Science.gov (United States)

    Laccourreye, O; Rubin, F; Villeneuve, A; Bonfils, P

    2017-09-01

    Only about ten articles devoted to operative reports have been published in the medical literature, but this document is essential, both medically and legally, to ensure optimal management of operated patients. In this technical note, based on published studies on this subject, the authors describe the key features of operating reports after otorhinolaryngology head & neck surgery and emphasize the need to write this document during the minutes after the end of the operation, the importance of standardization and its teaching role during surgical training. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Conceptual Drivers for an Exploration Medical System

    Science.gov (United States)

    Antonsen, Erik; Hanson, Andrea; Shah, Ronak; Reed, Rebekah; Canga, Michael

    2016-01-01

    Interplanetary spaceflight, such as NASA's proposed three-year mission to Mars, provides unique and novel challenges when compared with human spaceflight to date. Extended distance and multi-year missions introduce new elements of operational complexity and additional risk. These elements include: inability to resupply medications and consumables, inability to evacuate injured or ill crew, uncharted psychosocial conditions, and communication delays that create a requirement for some level of autonomous medical capability. Because of these unique challenges, the approaches used in prior programs have limited application to a Mars mission. On a Mars mission, resource limitations will significantly constrain available medical capabilities, and require a paradigm shift in the approach to medical system design and risk mitigation for crew health. To respond to this need for a new paradigm, the Exploration Medical Capability (ExMC) Element is assessing each Mars mission phase-transit, surface stay, rendezvous, extravehicular activity, and return-to identify and prioritize medical needs for the journey beyond low Earth orbit (LEO). ExMC is addressing both planned medical operations, and unplanned contingency medical operations that meld clinical needs and research needs into a single system. This assessment is being used to derive a gap analysis and studies to support meaningful medical capabilities trades. These trades, in turn, allow the exploration medical system design to proceed from both a mission centric and ethics-based approach, and to manage the risks associated with the medical limitations inherent in an exploration class mission. This paper outlines the conceptual drivers used to derive medical system and vehicle needs from an integrated vision of how medical care will be provided within this paradigm. Keywords: (Max 6 keywords: exploration, medicine, spaceflight, Mars, research, NASA)

  12. A guide for good practices in medical physics - French Society of Medical Physics

    International Nuclear Information System (INIS)

    Rosenwald, Jean-Claude; Aventin, Christophe; Coste, Frederic; Francois, Pascal; Ginestet, Chantal; Perrin, Benedicte; Salvat, Cecile; Caselles, Olivier; Dedieu, Veronique; Dejean, Catherine; Batalla, Alain; Guillaume, Bonniaud; LeDu, Dominique; Lisbona, Albert; Marchesi, Vincent; Sarrazin, Thierry; Mazeron, Jean-Jacques; Lipinski, Francis; Vera, Pierre; Maximilien Vermandel; Ducou le Pointe, Hubert; Vidal, Vincent; Henry, Cecile; Mazeau-Woynar, Valerie; Prot, Camille; Valero, Marc; Aubert, Bernard; Etard, Cecile; Jimonet, Christine; Roue, Amelie; Sage, Julie; Bardies, Manuel; Beauvais, Helene; Bey, Pierre; Costa, Andre; Desblancs, Claire; Eudaldo, Teresa; Farman, Bardia; Ferrand, Regis; Garcia, Robin; Giraud, Jean-Yves; Husson, Francois; Koulibaly, Malick; Carlan, Loic de; Manens, Jean-Pierre; Naudy, Suzanne; Noel, Alain; Pilette, Pierre; Verdun, Francis

    2012-12-01

    After a presentation of the methodological approach used to write this book, the first chapter addresses the profession of medical physicist: medical physics in France (history, evolution of the profession, of the education and of regulation), legal framework (related to the medical use of ionizing radiations, legal texts directly concerning medical physics, regulations impacting the professional practice of medical physicists), scopes of intervention of the medical physicist (context, missions, dose management, image quality, quality management and safety, relationship with the patient, education, training and research, relationships with industry, cost management), operating conditions, and good professional practices. The second chapter addresses the principles of management of quality and safety: quality management in medical physics, safety management, quality and safety in health care facilities. The third part addresses good practices in medical physics: general principles of working methods, equipment management, participation to clinic activities

  13. Medical Applications

    CERN Document Server

    Biscari, C.

    2014-12-19

    The use of accelerators for medical applications has evolved from initial experimentation to turn-key devices commonly operating in hospitals. New applications are continuously being developed around the world, and the hadrontherapy facilities of the newest generation are placed at the frontier between industrial production and advanced R&D. An introduction to the different medical application accelerators is followed by a description of the hadrontherapy facilities, with special emphasis on CNAO, and the report closes with a brief outlook on the future of this field.

  14. Medical Applications

    International Nuclear Information System (INIS)

    Biscari, C; Falbo, L

    2014-01-01

    The use of accelerators for medical applications has evolved from initial experimentation to turn-key devices commonly operating in hospitals. New applications are continuously being developed around the world, and the hadrontherapy facilities of the newest generation are placed at the frontier between industrial production and advanced R&D. An introduction to the different medical application accelerators is followed by a description of the hadrontherapy facilities, with special emphasis on CNAO, and the report closes with a brief outlook on the future of this field

  15. BROOKHAVEN: Proton goal reached

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    On March 30 the 35-year old Alternating Gradient Synchrotron (AGS) exceeded its updated design goal of 6 x 10 13 protons per pulse (ppp), by accelerating 6.3 x 10 13 ppp, a world record intensity. This goal was set 11 years ago and achieving it called for the construction of a new booster and the reconstruction of much of the AGS. The booster was completed in 1991, and reached its design intensity of 1.5 x 10 13 ppp in 1993. The AGS reconstruction was finished in 1994, and by July of that year the AGS claimed a new US record intensity for a proton synchrotron of 4 x 10 13 ppp, using four booster pulses. Reaching the design intensity was scheduled for 1995. In 1994, the AGS had seemed to be solidly limited to 4 x 10 13 ppp, but in 1995 the operations crew, working on their own in the quiet of the owl shift, steadily improved the intensity, regularly setting new records, much to the bemusement of the machine physicists. The physicists, however, did contribute. A second harmonic radiofrequency cavity in the booster increased the radiofrequency bucket area for capture, raising the booster intensity from 1.7 to 2.1 x 10 13 ppp. In the AGS, new radiofrequency power supplies raised the available voltage from 8 to 13 kV, greatly enhancing the beam loading capabilities of the system. A powerful new transverse damping system successfully controlled instabilities that otherwise would have destroyed the beam in less than a millisecond. Also in the AGS, 35th harmonic octupole resonances were found

  16. BROOKHAVEN: Proton goal reached

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-09-15

    On March 30 the 35-year old Alternating Gradient Synchrotron (AGS) exceeded its updated design goal of 6 x 10{sup 13} protons per pulse (ppp), by accelerating 6.3 x 10{sup 13} ppp, a world record intensity. This goal was set 11 years ago and achieving it called for the construction of a new booster and the reconstruction of much of the AGS. The booster was completed in 1991, and reached its design intensity of 1.5 x 10{sup 13} ppp in 1993. The AGS reconstruction was finished in 1994, and by July of that year the AGS claimed a new US record intensity for a proton synchrotron of 4 x 10{sup 13} ppp, using four booster pulses. Reaching the design intensity was scheduled for 1995. In 1994, the AGS had seemed to be solidly limited to 4 x 10{sup 13} ppp, but in 1995 the operations crew, working on their own in the quiet of the owl shift, steadily improved the intensity, regularly setting new records, much to the bemusement of the machine physicists. The physicists, however, did contribute. A second harmonic radiofrequency cavity in the booster increased the radiofrequency bucket area for capture, raising the booster intensity from 1.7 to 2.1 x 10{sup 13} ppp. In the AGS, new radiofrequency power supplies raised the available voltage from 8 to 13 kV, greatly enhancing the beam loading capabilities of the system. A powerful new transverse damping system successfully controlled instabilities that otherwise would have destroyed the beam in less than a millisecond. Also in the AGS, 35th harmonic octupole resonances were found.

  17. Operational safety enhancement of Soviet-designed nuclear reactors via development of nuclear power plant simulators and transfer of related technology

    International Nuclear Information System (INIS)

    Kohut, P.; Epel, L.G.; Tutu, N.K.

    1998-01-01

    The US Department of Energy (DOE), under the US government's International Nuclear Safety Program (INSP), is implementing a program of developing and providing simulators for many of the Russian and Ukrainian Nuclear Power Plants (NPPs). Pacific Northwest National Laboratory (PNNL) and Brookhaven National Laboratory (BNL) manage and provide technical oversight of the various INSP simulator projects for DOE. The program also includes a simulator technology transfer process to simulator design organizations in Russia and Ukraine. Training programs, installation of new simulators, and enhancements in existing simulators are viewed as providing a relatively fast and cost-effective technology transfer that will result in measurable improvement in the safety culture and operation of NPPs. A review of this program, its present status, and its accomplishments are provided in this paper

  18. Do radio frequencies of medical instruments common in the operating room interfere with near-infrared spectroscopy signals?

    Science.gov (United States)

    Shadgan, Babak; Molavi, Behnam; Reid, W. D.; Dumont, Guy; Macnab, Andrew J.

    2010-02-01

    Background: Medical and diagnostic applications of near infrared spectroscopy (NIRS) are increasing, especially in operating rooms (OR). Since NIRS is an optical technique, radio frequency (RF) interference from other instruments is unlikely to affect the raw optical data, however, NIRS data processing and signal output could be affected. Methods: We investigated the potential for three common OR instruments: an electrical cautery, an orthopaedic drill and an imaging system, to generate electromagnetic interference (EMI) that could potentially influence NIRS signals. The time of onset and duration of every operation of each device was recorded during surgery. To remove the effects of slow changing physiological variables, we first used a lowpass filter and then selected 2 windows with variable lengths around the moment of device onset. For each instant, variances (energy) and means of the signals in the 2 windows were compared. Results: Twenty patients were studied during ankle surgery. Analysis shows no statistically significant difference in the means and variance of the NIRS signals (p < 0.01) during operation of any of the three devices for all surgeries. Conclusion: This method confirms the instruments evaluated caused no significant interference. NIRS can potentially be used without EMI in clinical environments such as the OR.

  19. Medical Diplomacy: A Tool for Enabling National Security Strategy Objectives

    Science.gov (United States)

    2012-04-06

    USGs global health portfolio includes a diverse set of programs and investments in...cultural linguistic competency, expertise in regional medical initiatives, and knowledge of joint coordination in the ability foster medical goodwill...operates medical research units in Egypt and Peru . Additionally, the Navy has operated facilities in Indonesia and maintains research capabilities

  20. Radiation shielding and health physics instrumentation for PET medical cyclotrons

    International Nuclear Information System (INIS)

    Mukherjee, B.

    2002-01-01

    Full text: Modern Medical Cyclotrons produce a variety of short-lived positron emitting PET radioisotopes, and as a result are the source of intense neutron and gamma radiations. Since such cyclotrons are housed within hospitals or medical clinics, there is significant potential for un-intentional exposure to staff or patients in proximity to cyclotron facilities. Consequently, the radiological hazards associated with Cyclotrons provide the impetus for an effective radiological shielding and continuous monitoring of various radiation levels in the cyclotron environment. Management of radiological hazards is of paramount importance for the safe operation of a Medical Cyclotron facility. This work summarised the methods of shielding calculations for a compact hospital based Medical Cyclotron currently operating in Canada, USA and Australia. The design principle and operational history of a real-time health physics monitoring system (Watchdog) operating at a large multi-energy Medical Cyclotron is also highlighted

  1. Skylab medical technology utilization

    Science.gov (United States)

    Stonesifer, J. C.

    1974-01-01

    To perform the extensive medical experimentation on man in a long-term, zero-g environment, new medical measuring and monitoring equipment had to be developed, new techniques in training and operations were required, and new methods of collecting and analyzing the great amounts of medical data were developed. Examples of technology transfers to the public sector resulted from the development of new equipment, methods, techniques, and data. This paper describes several of the examples that stemmed directly from Skylab technology.

  2. Operation of the AGS polarized beam

    International Nuclear Information System (INIS)

    Ahrens, L.A.

    1988-01-01

    A polarized proton physics run took place during January, 1988, at the Brookhaven AGS. It is the purpose of this paper to review the tune-up period preceding that run. This was the third such run at the AGS; the others occurred in June of 1984 and February of 1986. Some comparisons will be drawn among these. A thorough review of the history and hardware associated with the acceleration of polarized protons at the AGS can be found in the proceedings of the last meeting of this group at Protvino and will not be repeated here. 2 refs., 6 figs., 1 tab

  3. Centralization vs. Decentralization in Medical School Libraries

    Science.gov (United States)

    Crawford, Helen

    1966-01-01

    Does the medical school library in the United States operate more commonly under the university library or the medical school administration? University-connected medical school libraries were asked to indicate (a) the source of their budgets, whether from the central library or the medical school, and (b) the responsibility for their acquisitions and cataloging. Returns received from sixtyeight of the seventy eligible institutions showed decentralization to be much the most common: 71 percent of the libraries are funded by their medical schools; 79 percent are responsible for their own acquisitions and processing. The factor most often associated with centralization of both budget and operation is public ownership. Decentralization is associated with service to one or two rather than three or more professional schools. Location of the medical school in a different city from the university is highly favorable to autonomy. Other factors associated with these trends are discussed. PMID:5945568

  4. Centralization vs. decentralization in medical school libraries.

    Science.gov (United States)

    Crawford, H

    1966-07-01

    Does the medical school library in the United States operate more commonly under the university library or the medical school administration? University-connected medical school libraries were asked to indicate (a) the source of their budgets, whether from the central library or the medical school, and (b) the responsibility for their acquisitions and cataloging. Returns received from sixtyeight of the seventy eligible institutions showed decentralization to be much the most common: 71 percent of the libraries are funded by their medical schools; 79 percent are responsible for their own acquisitions and processing. The factor most often associated with centralization of both budget and operation is public ownership. Decentralization is associated with service to one or two rather than three or more professional schools. Location of the medical school in a different city from the university is highly favorable to autonomy. Other factors associated with these trends are discussed.

  5. [The organizational characteristics of the medical support for the troops in the first operations at the start of a war (based on the experience of exercises)].

    Science.gov (United States)

    Iziumtsev, I S

    1995-03-01

    The article summarized the experience of an explorative tactical-special exercise on medical support of Mobile Forces in first military operations of the initial period of war which has studied the following questions: the organic structure and organization of work of the medical service of a motorized infantry brigade in defense; joint direction of organic hospital facilities and field traumatological hospital. The author also studies the deployment peculiarities of a military multipurpose hospital on the basis of a garrison hospital. The experience of these exercises has proved the necessity to update the organic structure and principles of the employment of medical assets in accordance with the requirements of new military doctrine, as well as realize the technical re-equipment of medical service.

  6. Recommendations of the International Medical Informatics Association (IMIA) on Education in Health and Medical Informatics

    Czech Academy of Sciences Publication Activity Database

    Arokiasamy, J.; Ball, M.; Barnett, D.; Bearman, M.; Bemmel van, J.; Douglas, J.; Fisher, P.; Garrie, R.; Gatewood, L.; Goossen, W.; Grant, A.; Hales, J.; Hasman, A.; Haux, R.; Hovenga, E.; Johns, M.; Knaup, P.; Leven, F. J.; Lorenzi, N.; Murray, P.; Neame, R.; Protti, D.; Power, M.; Richard, J.; Schuster, E.; Swinkels, W.; Yang, J.; Zelmer, L.; Zvárová, Jana

    2001-01-01

    Roč. 40, č. 5 (2001), s. 267-277 ISSN 0026-1270 Institutional research plan: AV0Z1030915 Keywords : health informatics * medical informatics * education * recommendations * International Medical Informatics Association * IMIA Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 1.254, year: 2001

  7. Leadership challenges in multinational medical peacekeeping operations: Lessons from UNIFIL Hospital.

    Science.gov (United States)

    Datta, Rakesh; Khanna, Sangeeta

    2017-10-01

    Commanding a military multinational and multilingual healthcare facility can be a formidable task with very little margin for error. The authors were in leadership positions of UNIFIL Hospital, unique in its diversity of both staff and clientele. Experience about the challenges faced and methods adopted to overcome them will be shared. Troops from diverse backgrounds differ in their competency, and also in their attitudinal approach to situations. It is imperative for the medical commanders to identify these differences, and work towards harnessing individual strengths to form a cohesive unit. Frequent rotation of team members and thereby difficulty in adapting to new environment makes the tasks more challenging. Challenges can be broadly categorized in those dealing with functional roles (providing medical support) and command and control issues. Linguistic challenges especially in situations where professionals have to work as a coordinated unit remains a major challenge. The threat of medical errors arising out of misunderstandings is very real. Gender sensitization is essential to avoid potential unpleasant situations. Interpersonal conflict can easily go out of hand. The leadership has to be more direct and deliberate relying less on hierarchy and more on direct communication. A strict enforcement of UN standards for equipment and competence, frequent joint medical drills help to overcome interoperability issues and develop mutual confidence. Leadership in multinational UN hospitals is a demanding task with its peculiar set of challenges. A systematic and deliberate approach focused on mutual respect, flexibility and direct leadership can help medical commanders in such situations.

  8. Medical records and issues in negligence

    Directory of Open Access Journals (Sweden)

    Joseph Thomas

    2009-01-01

    Full Text Available It is very important for the treating doctor to properly document the management of a patient under his care. Medical record keeping has evolved into a science of itself. This will be the only way for the doctor to prove that the treatment was carried out properly. Moreover, it will also be of immense help in the scientific evaluation and review of patient management issues. Medical records form an important part of the management of a patient. It is important for the doctors and medical establishments to properly maintain the records of patients for two important reasons. The first one is that it will help them in the scientific evaluation of their patient profile, helping in analyzing the treatment results, and to plan treatment protocols. It also helps in planning governmental strategies for future medical care. But of equal importance in the present setting is in the issue of alleged medical negligence. The legal system relies mainly on documentary evidence in a situation where medical negligence is alleged by the patient or the relatives. In an accusation of negligence, this is very often the most important evidence deciding on the sentencing or acquittal of the doctor. With the increasing use of medical insurance for treatment, the insurance companies also require proper record keeping to prove the patient′s demand for medical expenses. Improper record keeping can result in declining medical claims. It is disheartening to note that inspite of knowing the importance of proper record keeping it is still in a nascent stage in India. It is wise to remember that "Poor records mean poor defense, no records mean no defense". Medical records include a variety of documentation of patient′s history, clinical findings, diagnostic test results, preoperative care, operation notes, post operative care, and daily notes of a patient′s progress and medications. A properly obtained consent will go a long way in proving that the procedures were

  9. Large-scale User Facility Imaging and Scattering Techniques to Facilitate Basic Medical Research

    International Nuclear Information System (INIS)

    Miller, Stephen D.; Bilheux, Jean-Christophe; Gleason, Shaun Scott; Nichols, Trent L.; Bingham, Philip R.; Green, Mark L.

    2011-01-01

    Conceptually, modern medical imaging can be traced back to the late 1960's and into the early 1970's with the advent of computed tomography . This pioneering work was done by 1979 Nobel Prize winners Godfrey Hounsfield and Allan McLeod Cormack which evolved into the first prototype Computed Tomography (CT) scanner in 1971 and became commercially available in 1972. Unique to the CT scanner was the ability to utilize X-ray projections taken at regular angular increments from which reconstructed three-dimensional (3D) images could be produced. It is interesting to note that the mathematics to realize tomographic images was developed in 1917 by the Austrian mathematician Johann Radon who produced the mathematical relationships to derive 3D images from projections - known today as the Radon Transform . The confluence of newly advancing technologies, particularly in the areas of detectors, X-ray tubes, and computers combined with the earlier derived mathematical concepts ushered in a new era in diagnostic medicine via medical imaging (Beckmann, 2006). Occurring separately but at a similar time as the development of the CT scanner were efforts at the national level within the United States to produce user facilities to support scientific discovery based upon experimentation. Basic Energy Sciences within the United States Department of Energy currently supports 9 major user facilities along with 5 nanoscale science research centers dedicated to measurement sciences and experimental techniques supporting a very broad range of scientific disciplines. Tracing back the active user facilities, the Stanford Synchrotron Radiation Lightsource (SSRL) a SLAC National Accelerator Laboratory was built in 1974 and it was realized that its intense x-ray beam could be used to study protein molecular structure. The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory was commissioned in 1982 and currently has 60 x-ray beamlines optimized for a number of different

  10. Eliminating US hospital medical errors.

    Science.gov (United States)

    Kumar, Sameer; Steinebach, Marc

    2008-01-01

    Healthcare costs in the USA have continued to rise steadily since the 1980s. Medical errors are one of the major causes of deaths and injuries of thousands of patients every year, contributing to soaring healthcare costs. The purpose of this study is to examine what has been done to deal with the medical-error problem in the last two decades and present a closed-loop mistake-proof operation system for surgery processes that would likely eliminate preventable medical errors. The design method used is a combination of creating a service blueprint, implementing the six sigma DMAIC cycle, developing cause-and-effect diagrams as well as devising poka-yokes in order to develop a robust surgery operation process for a typical US hospital. In the improve phase of the six sigma DMAIC cycle, a number of poka-yoke techniques are introduced to prevent typical medical errors (identified through cause-and-effect diagrams) that may occur in surgery operation processes in US hospitals. It is the authors' assertion that implementing the new service blueprint along with the poka-yokes, will likely result in the current medical error rate to significantly improve to the six-sigma level. Additionally, designing as many redundancies as possible in the delivery of care will help reduce medical errors. Primary healthcare providers should strongly consider investing in adequate doctor and nurse staffing, and improving their education related to the quality of service delivery to minimize clinical errors. This will lead to an increase in higher fixed costs, especially in the shorter time frame. This paper focuses additional attention needed to make a sound technical and business case for implementing six sigma tools to eliminate medical errors that will enable hospital managers to increase their hospital's profitability in the long run and also ensure patient safety.

  11. Boleslas Matuszewski: Pioneer of medical film-making

    Directory of Open Access Journals (Sweden)

    Matanović Dragana

    2005-01-01

    Full Text Available Boleslas Matuszewski, born in 1856, was a pioneer in medical film-making. He worked simultaneously on improving his movie camera, film-making, collecting film documentation, and the idea of establishing an archive of medical films. Although his first attempts at filming and showing surgical operations didn't gain widespread approval, he was not discouraged, and succeeded in garnering support from a number of French doctors, who realized the importance of his ideas, not only in filming and forming medical film documentation, but also in the use of film for educative purposes. His visionary ideas gained acceptance when Dr. Doyen, on the occasion of the 66th Convention of the British Medical Society, in 1898, used film material as part of his lecture. Shortly afterwards, the Medical Academy took steps to show certain operative techniques, which represented both the confirmation and fruition of Matuszewski's ideas about filmmaking and the establishment of an archive of medical films.

  12. AN IMPACT OF THE EFFICIENT FUNCTIONING OF THE VENTILATION AND AIR-CONDITIONING SYSTEM ON THERMAL COMFORT OF THE MEDICAL STAFF IN THE OPERATING ROOM

    Directory of Open Access Journals (Sweden)

    Tomasz Jankowski

    2016-11-01

    Full Text Available Ventilation and air conditioning systems are necessary for developing proper parameters of indoor envi-ronment in operating rooms. The main task of ventilation and air conditioning in those specific areas consists in creating desirable temperature, reducing the number of microorganisms and the concen-trations of hazardous gases and substances in the air, as well as ensuring the proper direction of airflow. In Poland, indoor environment in operating rooms has to comply with the requirements set out in three regulations (Journal of Laws of 2002 No. 75, item 690, as amended, Journal of Laws of 2002 No. 217, item 1833, Journal of Laws of 2011 No. 31, item 158, as amended and the document entitled "Guidelines for the design of general hospitals". Given insufficient accuracy of the abovementioned national documents, it is a common practice to use foreign standards, i.e. ASHRAE Standard 170-2013, DIN 1946-4: 2008 and FprCEN TR 16244: 2011. When considering the conditions for thermal comfort, it is important to bear in mind a close link between air flow velocity and air temperature. Air in the zone occupied by patients and medical staff must not cause the sensation of draft. Furthermore, air velocity should be sufficient to eliminate interference caused by the presence of people and other sources of heat. It should also reduce the turbulence level in the air in the operating room. Efficient functioning of ventilation and air conditioning was tested during treatments and operations carried out on three wards of a Warsaw hospital. Tests were performed with the participation of medical staff from various surgical units. They were asked to perform minor manual tasks to simulate work on the op-erating table, and to complete a questionnaire on subjective thermal sensation. The applied methodology is widely used during testing of general and local ventilation in public buildings. Air temperature, relative humidity, air flow supply and exhaust air from the

  13. Preliminary comparison of MP sparking characteristics for SF6 insulating gas mixtures and pure SF6

    International Nuclear Information System (INIS)

    Lindgren, R.; Wegner, H.E.

    1978-01-01

    Operation of the Brookhaven MP-7 tandem Van de Graaff accelerator with pure SF 6 insulating gas is described. Sparking and terminal voltage were monitored and are compared for operation with a mixture of SF 6 , N 2 , CO 2 and O 2 . The accelerator was found to be more difficult to operate with pure SF 6

  14. 77 FR 4252 - Additional Spectrum for the Medical Device Radiocommunication Service

    Science.gov (United States)

    2012-01-27

    ... licensed users in these frequency bands to continue providing service. Medical Micro-Power Networks (MMNs...). Under this approach, medical devices would operate in the band on a shared, non-exclusive basis with...Radio Service rules for devices operating in the 413-457 MHz band. These definitions were for a Medical...

  15. Medical Imaging Informatics in Nuclear Medicine

    NARCIS (Netherlands)

    van Ooijen, Peter; Glaudemans, Andor W.J.M.; Medema, Jitze; van Zanten, Annie K.; Dierckx, Rudi A.J.O.; Ahaus, C.T.B. (Kees)

    2016-01-01

    Medical imaging informatics is gaining importance in medicine both in clinical practice and in scientific research. Besides radiology, nuclear medicine is also a major stakeholder in medical imaging informatics because of the variety of available imaging modalities and the imaging-oriented operation

  16. Now and Then: Combat Casualty Care Policies for Operation Iraqi Freedom and Operation Enduring Freedom Compared With Those of Vietnam

    National Research Council Canada - National Science Library

    Cordts, Paul R; Brosch, Laura A; Holcomb, John B

    2008-01-01

    Between December 2004 and June 2007, 13 key Operation Iraqi Freedom/ Operation Enduring Freedom combat casualty care policies were published to inform medical practice in the combat theater of operations...

  17. COMPUTATIONAL SCIENCE CENTER

    International Nuclear Information System (INIS)

    DAVENPORT, J.

    2006-01-01

    Computational Science is an integral component of Brookhaven's multi science mission, and is a reflection of the increased role of computation across all of science. Brookhaven currently has major efforts in data storage and analysis for the Relativistic Heavy Ion Collider (RHIC) and the ATLAS detector at CERN, and in quantum chromodynamics. The Laboratory is host for the QCDOC machines (quantum chromodynamics on a chip), 10 teraflop/s computers which boast 12,288 processors each. There are two here, one for the Riken/BNL Research Center and the other supported by DOE for the US Lattice Gauge Community and other scientific users. A 100 teraflop/s supercomputer will be installed at Brookhaven in the coming year, managed jointly by Brookhaven and Stony Brook, and funded by a grant from New York State. This machine will be used for computational science across Brookhaven's entire research program, and also by researchers at Stony Brook and across New York State. With Stony Brook, Brookhaven has formed the New York Center for Computational Science (NYCCS) as a focal point for interdisciplinary computational science, which is closely linked to Brookhaven's Computational Science Center (CSC). The CSC has established a strong program in computational science, with an emphasis on nanoscale electronic structure and molecular dynamics, accelerator design, computational fluid dynamics, medical imaging, parallel computing and numerical algorithms. We have been an active participant in DOES SciDAC program (Scientific Discovery through Advanced Computing). We are also planning a major expansion in computational biology in keeping with Laboratory initiatives. Additional laboratory initiatives with a dependence on a high level of computation include the development of hydrodynamics models for the interpretation of RHIC data, computational models for the atmospheric transport of aerosols, and models for combustion and for energy utilization. The CSC was formed to bring together

  18. Strange particles: production by Cosmotron beams as observed in diffusion cloud chambers

    International Nuclear Information System (INIS)

    Fowler, W.B.

    1989-01-01

    Proton beams, from the 1GeV Cosmotron accelerator at Brookhaven, were used in the 1950s to produce strange particles. One big leap forward technologically was the development of the diffusion cloud chamber which made detecting particle tracks more accurate and sensitive. A large co-operative team worked on its development. By the mid 1950s enough tracks had been observed to show the associated production of strange particles. It was the same Brookhaven workers who developed the eighty-inch hydrogen bubble chamber which took the first photograph of the long predicted omega minus particle at the end of the decade. (UK)

  19. A plea to control medical tourism.

    Science.gov (United States)

    Niechajev, Igor; Frame, James

    2012-02-01

    The growing phenomenon of patients seeking medical procedures abroad (MPA), formerly known as a medical tourism, is discussed. The dark side of the trend is exemplified by the tragic case of a 31-year-old Swedish woman who upon seeing a web advertisement went to Gdansk, Poland, to have breast augmentation. The operation was performed in an old hospital quite different from the modern hospital depicted in the ad. As a result of the grave mistakes in anesthetic care and lack of a postoperative recovery routine, the patient sustained severe brain injury because of prolonged hypoxia. Now, 6 months after the fateful operation, the patient is decorticated and has only vegetative functioning of the left side of the brain. Firm managers, who do not have any medical training, entice patients to believe that the doctors and the facilities abroad have the same technical and safety standards as at home. We question the gap in the law that allows a lay person to screen the candidates for surgery and decide who will operate and in what kind of environment. The trade in human organs is internationally banned but brokering operations on organs goes uncontrolled. Twenty other patients were operated on abroad at different facilities, but all told the same story: lack of adequate postoperative care, unfriendly nursing staff, and the feeling of abandonment upon the return home. The four facets of the ISAPS Patient Safety Diamond--the patient, the procedure, the facility, and the surgeon--are described. ISAPS decided to support the MPA policy with prescreening of the prospective patient, travel and medical insurance for the patient, and surgery abroad, but only if the surgeon is an ISAPS member in a fully accredited facility. This policy will be available first for UK residents who travel abroad for surgery, and later for patients and ISAPS surgeons worldwide. Many plastic surgeons have seen or heard of various tragedies or disasters following medical treatments in foreign countries

  20. INTERFACE ELECTRONIC MEDICAL CARD ON MOBILE DEVICE

    Directory of Open Access Journals (Sweden)

    Y. L. Nechyporenko

    2013-05-01

    Full Text Available The concept designed by electronic medical card for heterogeneous environment of medical information systems at various levels. Appropriate model and technical solution. Done evaluating operating systems for mobile devices. Designed and produced by the project mobile application on Android OS as an electronic medical record on a Tablet PC Acer.

  1. Wildland Fire Management Plan for Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Schwager, K.; Green, T. M.

    2014-01-01

    The DOE policy for managing wildland fires requires that all areas managed by DOE and/or Its various contractors which can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wildland fire, operational, and prescribed fires. FMPs provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled ''prescribed'' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. The plan will be reviewed periodically to ensure fire program advances and will evolve with the missions of DOE and BNL.

  2. Wildland Fire Management Plan for Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Schwager, K.; Green, T. M.

    2014-10-01

    The DOE policy for managing wildland fires requires that all areas managed by DOE and/or Its various contractors which can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wildland fire, operational, and prescribed fires. FMPs provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled ''prescribed'' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. The plan will be reviewed periodically to ensure fire program advances and will evolve with the missions of DOE and BNL.

  3. Effective Crew Operations: An Analysis of Technologies for Improving Crew Activities and Medical Procedures

    Science.gov (United States)

    Harvey, Craig

    2005-01-01

    NASA's vision for space exploration (February 2004) calls for development of a new crew exploration vehicle, sustained lunar operations, and human exploration of Mars. To meet the challenges of planned sustained operations as well as the limited communications between Earth and the crew (e.g., Mars exploration), many systems will require crews to operate in an autonomous environment. It has been estimated that once every 2.4 years a major medical issue will occur while in space. NASA's future travels, especially to Mars, will begin to push this timeframe. Therefore, now is the time for investigating technologies and systems that will support crews in these environments. Therefore, this summer two studies were conducted to evaluate the technology and systems that may be used by crews in future missions. The first study evaluated three commercial Indoor Positioning Systems (IPS) (Versus, Ekahau, and Radianse) that can track equipment and people within a facility. While similar to Global Positioning Systems (GPS), the specific technology used is different. Several conclusions can be drawn from the evaluation conducted, but in summary it is clear that none of the systems provides a complete solution in meeting the tracking and technology integration requirements of NASA. From a functional performance (e.g., system meets user needs) evaluation perspective, Versus performed fairly well on all performance measures as compared to Ekahau and Radianse. However, the system only provides tracking at the room level. Thus, Versus does not provide the level of fidelity required for tracking assets or people for NASA requirements. From an engineering implementation perspective, Ekahau is far simpler to implement that the other two systems because of its wi-fi design (e.g., no required runs of cable). By looking at these two perspectives, one finds there was no clear system that met NASA requirements. Thus it would be premature to suggest that any of these systems are ready for

  4. A description of morbidly obese state employees requesting a bariatric operation.

    Science.gov (United States)

    Martin, Louis F; Lundberg, Anna Paone; Juneau, Francine; Raum, William J; Hartman, Sandra J

    2005-10-01

    The federal government, the medical insurance industry, and the academic medical community have disagreed over what treatments are appropriate and cost effective for morbid obesity. This debate is hindered by inadequate data regarding the true costs of diseases and who chooses an operation as a treatment option. The purpose of this study was to obtain these costs and to describe this population. Louisiana's managed medical insurance program created primarily for its civil service employees contracted to offer a small random group of morbidly obese employees the option of a bariatric operation. This observational study examined the subpopulation who requested consideration for the operation. We present historic cost data from all medical expenses paid by the insurance company, a telephone survey of the volunteers in the study to determine their medical problems, and diagnostic evaluation data on those employees randomized to proceed for possible bariatric operation. A total of 911 of 189,398 adult members of the insurance plan wanted to be considered for this study. Only 397, however, completed the informed-consent process. Of the 248 employees who met the age requirement, body mass index criteria, and health criteria to be considered for a bariatric operation and were randomized, 20 withdrew before obtaining 40 committed operative candidates. The 773 morbidly obese female members had used a mean of dollar 11,145 in medical insurance expenses in the year 2003 versus a mean of dollar 8,096 for the other 106,908 adult women. Similar values for the men were dollar 16,720 for the 138 morbidly obese men versus dollar 5,943 for the other 82,490 men. The morbidly obese members of this medical insurance plan who requested a bariatric operation are costing their plan 1.4 to 2.8 times the yearly amount of the other adult members in medical expenses. The yearly mean amount the insurance plan spends on these members suggests that operative treatment would pay for itself in a

  5. Shuttle OFT medical report: Summary of medical results from STS-1, STS-2, STS-3, and STS-4

    Science.gov (United States)

    Pool, S. L. (Editor); Johnson, P. C., Jr. (Editor); Mason, J. A. (Editor)

    1983-01-01

    The medical operations for the orbital test flights which includes a review of the health of the crews before, during, and immediately after the four shuttle orbital flights are reported. Health evaluation, health stabilization program, medical training, medical "kit" carried in flight, tests and countermeasures for space motion sickness, cardiovascular, biochemistry and endocrinology results, hematology and immunology analyses, medical microbiology, food and nutrition, potable water, Shuttle toxicology, radiological health, and cabin acoustical noise are reviewed. Information on environmental effects of Shuttle launch and landing, medical information management, and management, planning, and implementation of the medical program are included.

  6. A study of actions in operative notes.

    Science.gov (United States)

    Wang, Yan; Pakhomov, Serguei; Burkart, Nora E; Ryan, James O; Melton, Genevieve B

    2012-01-01

    Operative notes contain rich information about techniques, instruments, and materials used in procedures. To assist development of effective information extraction (IE) techniques for operative notes, we investigated the sublanguage used to describe actions within the operative report 'procedure description' section. Deep parsing results of 362,310 operative notes with an expanded Stanford parser using the SPECIALIST Lexicon resulted in 200 verbs (92% coverage) including 147 action verbs. Nominal action predicates for each action verb were gathered from WordNet, SPECIALIST Lexicon, New Oxford American Dictionary and Stedman's Medical Dictionary. Coverage gaps were seen in existing lexical, domain, and semantic resources (Unified Medical Language System (UMLS) Metathesaurus, SPECIALIST Lexicon, WordNet and FrameNet). Our findings demonstrate the need to construct surgical domain-specific semantic resources for IE from operative notes.

  7. A study of RFID application impacts on medical safety.

    Science.gov (United States)

    Chang, She-I; Ou, Chin-Shyh; Ku, Cheng-Yuan; Yang, Morris

    2008-01-01

    With the international reform in medical management systems gaining ground worldwide, hospital management has gradually begun to shift its focus from providing expensive medical treatment to improving medical service quality and patient safety. In this study, we discuss the application of Radio Frequency Identification (RFID) and data integrating technology with the medical service, and examine whether or not this technology can enhance medical safety. We also discuss the possible benefits following the application of the RFID system. The findings show that the application of RFID to hospitals can actually generate benefits, which can be further divided into operational structure benefits, users' structure benefits, and organisational and environmental benefits. However, not all these benefits can achieve medical safety. Among them, only the operator and environmental benefits can play such roles. Nevertheless, the application of RFID can bring hospitals towards the integration of technology benefits and improved medical safety.

  8. Risk contribution from low power, shutdown, and other operational modes beyond full power

    Energy Technology Data Exchange (ETDEWEB)

    Whitehead, D.W.; Brown, T.D. [Sandia National Labs., Albuquerque, NM (United States); Chu, T.L. [Brookhaven National Lab., Upton, NY (United States)] [and others

    1995-04-01

    During 1989 the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. Two plants, Surry (a pressurized water reactor) and Grand Gulf (a boiling water reactor), were selected for study by Brookhaven National Laboratory and Sandia National Laboratories, respectively. The program objectives included assessing the risks of severe accidents initiated during plant operational states other than full power and comparing estimated core damage frequencies, important accident sequences, and other qualitative and quantitative results with full power accidents as assessed in NUREG-1150. The scope included a Level 3 probabilistic risk assessment (PRA) for traditional internal events and a Level 1 PRA on fire, flooding, and seismically induced core damage sequences. A phased approach was used in Level 1. In Phase 1 the concept of plant operational states (POSs) was developed to provide a better representation of the plant as it transitions from power to nonpower operation. This included a coarse screening analysis of all POSs to identify vulnerable plant configurations, to characterize (on a high, medium, or low basis) potential frequencies of core damage accidents, and to provide a foundation for a detailed Phase 2 analysis. In Phase 2, selected POSs from both Grand Gulf and Surry were chosen for detailed analysis. For Grand Gulf, POS 5 (approximately cold shutdown as defined by Grand Gulf Technical Specifications) during a refueling outage was selected. For Surry, three POSs representing the time the plant spends in midloop operation were chosen for analysis. These included POS 6 and POS 10 of a refueling outage and POS 6 of a drained maintenance outage. Level 1 and Level 2/3 results from both the Surry and Grand Gulf analyses are presented.

  9. Risk contribution from low power, shutdown, and other operational modes beyond full power

    International Nuclear Information System (INIS)

    Whitehead, D.W.; Brown, T.D.; Chu, T.L.; Pratt, W.T.

    1995-01-01

    During 1989 the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. Two plants, Surry (a pressurized water reactor) and Grand Gulf (a boiling water reactor), were selected for study by Brookhaven National Laboratory and Sandia National Laboratories, respectively. The program objectives included assessing the risks of severe accidents initiated during plant operational states other than full power and comparing estimated core damage frequencies, important accident sequences, and other qualitative and quantitative results with full power accidents as assessed in NUREG-1150. The scope included a Level 3 probabilistic risk assessment (PRA) for traditional internal events and a Level 1 PRA on fire, flooding, and seismically induced core damage sequences. A phased approach was used in Level 1. In Phase 1 the concept of plant operational states (POSs) was developed to provide a better representation of the plant as it transitions from power to nonpower operation. This included a coarse screening analysis of all POSs to identify vulnerable plant configurations, to characterize (on a high, medium, or low basis) potential frequencies of core damage accidents, and to provide a foundation for a detailed Phase 2 analysis. In Phase 2, selected POSs from both Grand Gulf and Surry were chosen for detailed analysis. For Grand Gulf, POS 5 (approximately cold shutdown as defined by Grand Gulf Technical Specifications) during a refueling outage was selected. For Surry, three POSs representing the time the plant spends in midloop operation were chosen for analysis. These included POS 6 and POS 10 of a refueling outage and POS 6 of a drained maintenance outage. Level 1 and Level 2/3 results from both the Surry and Grand Gulf analyses are presented

  10. Persistent pain and comorbidity among Operation Enduring Freedom/Operation Iraqi Freedom/operation New Dawn veterans.

    Science.gov (United States)

    Higgins, Diana M; Kerns, Robert D; Brandt, Cynthia A; Haskell, Sally G; Bathulapalli, Harini; Gilliam, Wesley; Goulet, Joseph L

    2014-05-01

    Chronic pain is a significant concern for the Veterans Health Administration (VHA), with chronic pain conditions among those most frequently reported by Operation Enduring Freedom (OEF)/Operation Iraqi Freedom (OIF)/Operation New Dawn (OND) veterans. The current study examined VHA electronic medical record data to examine variation in demographics and high prevalence and high impact medical and mental health conditions in order to characterize the differences between patients with persistent pain and no pain. A conservative operational definition of chronic or "persistent pain" based on multiple indicators of pain (i.e., pain intensity ratings, prescription opioids, pain clinic visits, International Classification of Diseases, Ninth Revision codes) was employed. Analyses included the entire roster of longitudinal clinical data on OEF/OIF/OND veterans who used VHA care to compare those with persistent pain with those with no clinical evidence of pain. Results of logistic regression models suggest that sex, race, education, military variables, body mass index (BMI), traumatic brain injury (TBI), and mental health conditions, but not age, reliably discriminate the two groups. Those with persistent pain were more likely to be Black, female, on active duty, enlisted, Army service members, have a high school education or less, and have diagnoses of mood disorders, post-traumatic stress disorder, substance use disorders, anxiety disorders, TBI, and have a BMI consistent with overweight and obesity. The operational definition of chronic pain used in this study may have research implications for examining predictors of incident and chronic pain. These data have important clinical implications in that addressing comorbid conditions of persistent pain may improve adaptive coping and functioning in these patients. Wiley Periodicals, Inc.

  11. The Future Medical Science and Colorectal Surgeons.

    Science.gov (United States)

    Kim, Young Jin

    2017-12-01

    Future medical technology breakthroughs will build from the incredible progress made in computers, biotechnology, and nanotechnology and from the information learned from the human genome. With such technology and information, computer-aided diagnoses, organ replacement, gene therapy, personalized drugs, and even age reversal will become possible. True 3-dimensional system technology will enable surgeons to envision key clinical features and will help them in planning complex surgery. Surgeons will enter surgical instructions in a virtual space from a remote medical center, order a medical robot to perform the operation, and review the operation in real time on a monitor. Surgeons will be better than artificial intelligence or automated robots when surgeons (or we) love patients and ask questions for a better future. The purpose of this paper is looking at the future medical science and the changes of colorectal surgeons.

  12. The Linux farm at the RCF

    International Nuclear Information System (INIS)

    Chan, A.W.; Hogue, R.W.; Throwe, T.G.; Yanuklis, T.A.

    2001-01-01

    A description of the Linux Farm at the RHIC Computing Facility (RCF) is presented. The RCF is a dedicated data processing facility for RHIC, which became operational in the summer of 2000 at Brookhaven National Laboratory

  13. Effect of Pre-Operative Use of Medications on the Risk of Surgical Site Infections in Patients Undergoing Cardiac Surgery.

    Science.gov (United States)

    Eton, Vic; Sinyavskaya, Liliya; Langlois, Yves; Morin, Jean François; Suissa, Samy; Brassard, Paul

    2016-10-01

    Median sternotomy, the most common means of accessing the heart for cardiac procedures, is associated with higher risk of surgical site infections (SSIs). A limited number of studies reporting the impact of medication use prior to cardiac surgery on the subsequent risk of SSIs usually focused on antibacterial prophylaxis. The objective of the current study was to evaluate the effect of medications prescribed commonly to cardiac patients on the risk of incident SSIs. The study analyzed data on consecutive cardiac surgery patients undergoing median sternotomy at a McGill University teaching hospital between April 1, 2011 and October 31, 2013. Exposure of interest was use of medications for heart disease and cardiovascular conditions in the seven days prior to surgery and those for comorbid conditions. The main outcome was SSIs occurring within 90 d after surgery. Univariate and multivariate logistic regression (adjusted odds ratio [AOR]) was used to evaluate the effect. The cohort included 1,077 cardiac surgery patients, 79 of whom experienced SSIs within 90 d of surgery. The rates for sternal site infections and harvest site infections were 5.8 (95% confidence interval [CI]: 4.4-7.3) and 2.5 (95% CI: 1.4-3.7) per 100 procedures, respectively. The risk of SSI was increased with the pre-operative use of immunosuppressors/steroids (AOR 3.47, 95% CI: 1.27-9.52) and α-blockers (AOR 3.74, 95% CI: 1.21-1.47). Our findings support the effect of immunosuppressors/steroids on the risk of SSIs and add evidence to the previously reported association between the use of anti-hypertensive medications and subsequent development of infection/sepsis.

  14. Retrospective Chart Review of Skin-to-Skin Contact in the Operating Room and Administration of Analgesic and Anxiolytic Medication to Women After Cesarean Birth.

    Science.gov (United States)

    Wagner, Debra L; Lawrence, Stephen; Xu, Jing; Melsom, Janice

    2018-04-01

    Transporting a newborn out of the operating room after cesarean birth can contribute to maternal awareness of discomfort, anxiety, and the need for administration of analgesics and anxiolytics for relief. This retrospective study analyzed the association between skin-to-skin contact in the operating room and administration of analgesics and anxiolytics to women in the operating and recovery rooms after cesarean birth. Our results indicated a trend toward decreased medication administration for women who experienced skin-to-skin contact and add to evidence supporting the incorporation of skin-to-skin contact in the operating room as the standard of care for cesarean birth. This practice has the potential to enhance the birth experience, promote breastfeeding, and provide greater safety with less exposure to opioids and benzodiazepines for women and their newborns. © 2018 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses.

  15. Intriguing aspects in baryon production at relativistic heavy-ion collider

    Indian Academy of Sciences (India)

    The commencement of the relativistic heavy ion collider (RHIC) operation at Brookhaven ... that an unprecedented high-energy density has been achieved in ... for charged particles and measurement of ionization energy loss (dE/dx) for limited ...

  16. [Medical negligence in surgery: 112 cases retrospective analysis].

    Science.gov (United States)

    Xiang, Jian; Chang, Lin; Wang, Xu; Zhang, Feng-Qin

    2013-06-01

    To explore the general characteristics of medical negligence in surgery in order to provide the reference for forensic practices. One hundred and twelve cases of medical negligence in surgical department were retrospectively analyzed in Fada Institute of Forensic Medicine and Science from 2008 to 2010. The common types of medical negligence cases in the surgery were improper operation procedure (28.57%), failure of consent (26.79%), and inadequate monitoring (22.32%). The results of complications included disability or functional impairment (61.61%), death (31.25%) and transient impairment with no obvious adverse reactions (7.14%). The most common roles played by the medical negligence cases were minor role (26.79%), equal role (19.64%), and slight role (14.29%). Significant attention should be paid to the operation procedure, consent, and monitoring. It should be cautious to not make assessment on involvement degree of medical negligence.

  17. Acceso y usabilidad de medicamentos: propuesta para una definición operacional Access and usability to medications: a proposal for an operational definition

    Directory of Open Access Journals (Sweden)

    Teodoro J. Oscanoa

    2012-03-01

    Full Text Available Las investigaciones sobre accesibilidad a medicamentos con encuestas a hogares, son de gran importancia para verificar la realidad y eficacia de las medidas de intervención para mejorar el acceso de medicamentos en la población. Desafortunadamente dichos estudios, además de ser escasos, presentan problemas metodológicos, que en su mayor parte son consecuencia de una ausencia de uniformidad en las definiciones operacionales de acceso y su diferenciación con las dimensiones de la accesibilidad. El objetivo de la propuesta es diferenciar ambos términos. Se propone definir operacionalmente acceso a medicamentos al proceso de verificación de la obtención de un fármaco por un paciente, independiente de diversos factores que pueden afectar el proceso. Se introduce el término "Usabilidad de fármacos", definiéndolo operacionalmente como los procesos destinados a medir las dimensiones de la accesibilidad de los medicamentos: disponibilidad física, asequibilidad, accesibilidad geográfica, aceptabilidad (o satisfacción.Research about accessibility to medicines through household surveys is very important in order to verify the reality and effectiveness of interventions done to increase the access of the population to the medications. Unfortunately, such studies, on top of being very few, have methodological problems, which mostly result from a lack of uniformity in the operational definitions of access and the differentiation with the dimensions of accessibility. The aim of this paper is to propose setting a difference between both terms. We propose an operational definition of access to medications as the process of verification of the purchase of a drug by a patient, independently from many factors that can affect this process. The term "usability of drugs" is introduced, defining it operationally as aimed at measuring the dimensions of the accessibility to the medications: physical availability, affordability, geographical accessibility

  18. High-precision gamma-ray spectroscopy for enhancing production and application of medical isotopes

    Science.gov (United States)

    McCutchan, E. A.; Sonzogni, A. A.; Smith, S. V.; Muench, L.; Nino, M.; Greene, J. P.; Carpenter, M. P.; Zhu, S.; Chillery, T.; Chowdhury, P.; Harding, R.; Lister, C. J.

    2015-10-01

    Nuclear medicine is a field which requires precise decay data for use in planning radionuclide production and in imaging and therapeutic applications. To address deficiencies in decay data, sources of medical isotopes were produced and purified at the Brookhaven Linear Isotope Producer (BLIP) then shipped to Argonne National Laboratory where high-precision, gamma-ray measurements were performed using Gammasphere. New decay schemes for a number of PET isotopes and the impact on dose calculations will be presented. To investigate the production of next-generation theranostic or radiotherapeutic isotopes, cross section measurements with high energy protons have also been explored at BLIP. The 100-200 MeV proton energy regime is relatively unexplored for isotope production, thus offering high discovery potential but at the same time a challenging analysis due to the large number of open channels at these energies. Results of cross sections deduced from Compton-suppressed, coincidence gamma-ray spectroscopy performed at Lowell will be presented, focusing on the production of platinum isotopes by irradiating natural platinum foils with 100 to 200 MeV protons. DOE Isotope Program is acknowledged for funding ST5001030. Work supported by the US DOE under Grant DE-FG02-94ER40848 and Contracts DE-AC02-98CH10946 and DE-AC02-06CH11357.

  19. Sleep Disruption Medical Intervention Forecasting (SDMIF) Module for the Integrated Medical Model

    Science.gov (United States)

    Lewandowski, Beth; Brooker, John; Mallis, Melissa; Hursh, Steve; Caldwell, Lynn; Myers, Jerry

    2011-01-01

    The NASA Integrated Medical Model (IMM) assesses the risk, including likelihood and impact of occurrence, of all credible in-flight medical conditions. Fatigue due to sleep disruption is a condition that could lead to operational errors, potentially resulting in loss of mission or crew. Pharmacological consumables are mitigation strategies used to manage the risks associated with sleep deficits. The likelihood of medical intervention due to sleep disruption was estimated with a well validated sleep model and a Monte Carlo computer simulation in an effort to optimize the quantity of consumables. METHODS: The key components of the model are the mission parameter program, the calculation of sleep intensity and the diagnosis and decision module. The mission parameter program was used to create simulated daily sleep/wake schedules for an ISS increment. The hypothetical schedules included critical events such as dockings and extravehicular activities and included actual sleep time and sleep quality. The schedules were used as inputs to the Sleep, Activity, Fatigue and Task Effectiveness (SAFTE) Model (IBR Inc., Baltimore MD), which calculated sleep intensity. Sleep data from an ISS study was used to relate calculated sleep intensity to the probability of sleep medication use, using a generalized linear model for binomial regression. A human yes/no decision process using a binomial random number was also factored into sleep medication use probability. RESULTS: These probability calculations were repeated 5000 times resulting in an estimate of the most likely amount of sleep aids used during an ISS mission and a 95% confidence interval. CONCLUSIONS: These results were transferred to the parent IMM for further weighting and integration with other medical conditions, to help inform operational decisions. This model is a potential planning tool for ensuring adequate sleep during sleep disrupted periods of a mission.

  20. Comfort Ye My People: Chaplains, Spiritual Care, and Operational Stress Injury

    Science.gov (United States)

    2011-04-30

    post - traumatic stress disorder ( PTSD ), operational stress injury (OSI...combat operational stress injury and post - traumatic stress disorder yet, of necessity, their work is grounded in a medical model ill equipped to...into combat operational stress injury and post - traumatic stress disorder yet, of necessity’ their work is groWlded in. a medical model ill equipped

  1. Medical student fitness to practise committees at UK medical schools

    Directory of Open Access Journals (Sweden)

    Aldridge Jocelyne

    2009-06-01

    Full Text Available Abstract Background The aim was to explore the structures for managing student fitness to practise hearings in medical schools in the UK. We surveyed by email the named fitness to practise leads of all full members of the UK Medical Schools Council with a medical undergraduate programme. We asked whether student fitness to practise cases were considered by a committee/panel dedicated to medicine, or by one which also considered other undergraduate health and social care students. Findings All 31 medical schools responded. 19 medical schools had a fitness to practise committee dealing with medical students only. Three had a committee that dealt with students of medicine and dentistry. One had a committee that dealt with students of medicine and veterinary medicine. Eight had a committee that dealt with students of medicine and two or more other programmes, such as dentistry, nursing, midwifery, physiotherapy, dietetics, social work, pharmacy, psychology, audiology, speech therapy, operating department practice, veterinary medicine and education. Conclusion All 31 UK medical schools with undergraduate programmes have a fitness to practise committee to deal with students whose behaviour has given rise to concern about their fitness to practise. The variation in governance structures for student fitness to practise committees/panels can in part be explained by variations in University structures and the extent to which Universities co-manage undergraduate medicine with other courses.

  2. Aerospace Medical Support in Russia

    Science.gov (United States)

    Castleberry, Tara; Chamberlin, Blake; Cole, Richard; Dowell, Gene; Savage, Scott

    2011-01-01

    This slide presentation reviews the role of the flight surgeon in support of aerospace medical support operations at the Gagarin Cosmonaut Training Center (GCTC), also known as Star City, in Russia. The flight surgeon in this role is the medical advocate for non-russian astronauts, and also provides medical care for illness and injury for astronauts, family members, and guests as well as civil servants and contractors. The flight surgeon also provides support for hazardous training. There are various photos of the area, and the office, and some of the equipment that is used.

  3. STS-2 medical report

    International Nuclear Information System (INIS)

    Pool, S.L.; Johnson, P.C. Jr.; Mason, J.A.

    1982-05-01

    All medically related activities of the Space Transportation System 2 flight are described, ranging from preflight to postflight. Several medical problems occured during the flight. There was marginal operation on-board potable water system caused by a malfunctioning fuel cell. Work and rest cycles by the crew were altered to maximize the scientific data acquisition. Inadequate time was allocated for food preparation and consumption. There was low water intake by the crew because of the water shortage

  4. The issue of thermal comfort of medical clothing in the operating room

    OpenAIRE

    Abreu, Isabel; Ribeiro, Patrícia; Abreu, Maria José

    2017-01-01

    Abstract Medical clothes have the primary function of protection. However this function must be correlated with a good comfort experience to the user. The comfort is a very important issue, since professionals are exposed to stress situations that can influence, negatively, their performance work. More specific, thermal comfort plays a crucial role for the best performance of OR medical clothing, involving heat regulation and mass transfer between a clothed body and the environment, once clot...

  5. Stereoscopic medical imaging collaboration system

    Science.gov (United States)

    Okuyama, Fumio; Hirano, Takenori; Nakabayasi, Yuusuke; Minoura, Hirohito; Tsuruoka, Shinji

    2007-02-01

    The computerization of the clinical record and the realization of the multimedia have brought improvement of the medical service in medical facilities. It is very important for the patients to obtain comprehensible informed consent. Therefore, the doctor should plainly explain the purpose and the content of the diagnoses and treatments for the patient. We propose and design a Telemedicine Imaging Collaboration System which presents a three dimensional medical image as X-ray CT, MRI with stereoscopic image by using virtual common information space and operating the image from a remote location. This system is composed of two personal computers, two 15 inches stereoscopic parallax barrier type LCD display (LL-151D, Sharp), one 1Gbps router and 1000base LAN cables. The software is composed of a DICOM format data transfer program, an operation program of the images, the communication program between two personal computers and a real time rendering program. Two identical images of 512×768 pixcels are displayed on two stereoscopic LCD display, and both images show an expansion, reduction by mouse operation. This system can offer a comprehensible three-dimensional image of the diseased part. Therefore, the doctor and the patient can easily understand it, depending on their needs.

  6. Comprehensive Performance Nutrition for Special Operations Forces.

    Science.gov (United States)

    Daigle, Karen A; Logan, Christi M; Kotwal, Russ S

    2015-01-01

    Special Operations Forces (SOF) training, combat, and contingency operations are unique and demanding. Performance nutrition within the Department of Defense has emphasized that nutrition is relative to factors related to the desired outcome, which includes successful performance of mentally and physically demanding operations and missions of tactical and strategic importance, as well as nonoperational assignments. Discussed are operational, nonoperational, and patient categories that require different nutrition strategies to facilitate category-specific performance outcomes. Also presented are 10 major guidelines for a SOF comprehensive performance nutrition program, practical nutrition recommendations for Special Operators and medical providers, as well as resources for dietary supplement evaluation. Foundational health concepts, medical treatment, and task-specific performance factors should be considered when developing and systematically implementing a comprehensive SOF performance nutrition program. When tailored to organizational requirements, SOF unit- and culture-specific nutrition education and services can optimize individual Special Operator performance, overall unit readiness, and ultimately, mission success. 2015.

  7. The neoplasms of the operated stomach

    International Nuclear Information System (INIS)

    Ositrova, L.I.; Golubovich, I.A.; Mashevskaya, L.S.

    1988-01-01

    It is shown that operation and rexction in case of primary and recurrent neoplasm of operated stomach remains low. However radical operation is the only method permitting to hope for healing of shuch patients. A thorough medical examination is necessary at first 3 years following operation. Surgical treatment is accompanied by preoperational irradiation in such patients. Au 198 in 1.48 GBq is intravenously injected to some patients. 10 refs

  8. Medical tourism private hospitals: focus India.

    Science.gov (United States)

    Brotman, Billie Ann

    2010-01-01

    This article examines demand factors for sophisticated medical treatments offered by private hospitals operating in India. Three types of medical tourism exist: Outbound, Inbound, and Intrabound. Increased profitability and positive growth trends by private hospital chains can be attributed to rising domestic income levels within India. Not all of the chains examined were financially solvent. Some of the hospital groups in this sample that advertised directly to potential Inbound medical tourists appear to be experiencing negative cash flows.

  9. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Evaluation of severe accident risks for plant operational state 5 during a refueling outage. Main report and appendices, Volume 6, Part 1

    International Nuclear Information System (INIS)

    Brown, T.D.; Kmetyk, L.N.; Whitehead, D.; Miller, L.; Forester, J.; Johnson, J.

    1995-03-01

    Traditionally, probabilistic risk assessments (PRAS) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Recent studies and operational experience have, however, implied that accidents during low power and shutdown could be significant contributors to risk. In response to this concern, in 1989 the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The program consists of two parallel projects being performed by Brookhaven National Laboratory (Surry) and Sandia National Laboratories (Grand Gulf). The program objectives include assessing the risks of severe accidents initiated during plant operational states other than full power operation and comparing the estimated risks with the risk associated with accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program is that of a Level-3 PRA. The subject of this report is the PRA of the Grand Gulf Nuclear Station, Unit 1. The Grand Gulf plant utilizes a 3833 MWt BUR-6 boiling water reactor housed in a Mark III containment. The Grand Gulf plant is located near Port Gibson, Mississippi. The regime of shutdown analyzed in this study was plant operational state (POS) 5 during a refueling outage, which is approximately Cold Shutdown as defined by Grand Gulf Technical Specifications. The entire PRA of POS 5 is documented in a multi-volume NUREG report (NUREG/CR-6143). The internal events accident sequence analysis (Level 1) is documented in Volume 2. The Level 1 internal fire and internal flood analyses are documented in Vols 3 and 4, respectively

  10. Evaluation of potential severe accidents during low power and shutdown operations at Grand Gulf, Unit 1: Evaluation of severe accident risks for plant operational state 5 during a refueling outage. Main report and appendices, Volume 6, Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Brown, T.D.; Kmetyk, L.N.; Whitehead, D.; Miller, L. [Sandia National Labs., Albuquerque, NM (United States); Forester, J. [Science Applications International Corp., Albuquerque, NM (United States); Johnson, J. [GRAM, Inc., Albuquerque, NM (United States)

    1995-03-01

    Traditionally, probabilistic risk assessments (PRAS) of severe accidents in nuclear power plants have considered initiating events potentially occurring only during full power operation. Recent studies and operational experience have, however, implied that accidents during low power and shutdown could be significant contributors to risk. In response to this concern, in 1989 the Nuclear Regulatory Commission (NRC) initiated an extensive program to carefully examine the potential risks during low power and shutdown operations. Two plants, Surry (pressurized water reactor) and Grand Gulf (boiling water reactor), were selected as the plants to be studied. The program consists of two parallel projects being performed by Brookhaven National Laboratory (Surry) and Sandia National Laboratories (Grand Gulf). The program objectives include assessing the risks of severe accidents initiated during plant operational states other than full power operation and comparing the estimated risks with the risk associated with accidents initiated during full power operation as assessed in NUREG-1150. The scope of the program is that of a Level-3 PRA. The subject of this report is the PRA of the Grand Gulf Nuclear Station, Unit 1. The Grand Gulf plant utilizes a 3833 MWt BUR-6 boiling water reactor housed in a Mark III containment. The Grand Gulf plant is located near Port Gibson, Mississippi. The regime of shutdown analyzed in this study was plant operational state (POS) 5 during a refueling outage, which is approximately Cold Shutdown as defined by Grand Gulf Technical Specifications. The entire PRA of POS 5 is documented in a multi-volume NUREG report (NUREG/CR-6143). The internal events accident sequence analysis (Level 1) is documented in Volume 2. The Level 1 internal fire and internal flood analyses are documented in Vols 3 and 4, respectively.

  11. Assessment of Clinical Stressful Factors Among Academic Students of Nursing and Operating Room of Dezful University of Medical Sciences (2015

    Directory of Open Access Journals (Sweden)

    Mojtaba Raji

    2016-07-01

    Full Text Available Background and Objective: Nursing students are exposed to clinical environmental stresses in addition to educational environmental stresses. The aim of this study was to assessment of clinical stressful factors among Academic Students of Nursing and Operating Room of Dezful University of Medical Sciences in 2015.Materials and Methods: This study was a description-analytical study with 234 students of nursing and operation room up to two semesters for enrolled. Data was using a self-made researcher Questionnaire consisted of demographic information and clinical stressful factors. Data analysis was performed by descriptive and inferential statistics using SPSS-PC (v.20.Results: The findings showed that the main stressors in students of nursing and operation room were unpleasant emotions and least stressful areas were interpersonal communication in a clinical environment. The results showed that the average score of the field of education and humiliating experiences using Spearman correlation test (P=0/045 (r=0/16.Conclusion: Study showed, the mean stress is the moderate level. Stressful areas obtained in the four areas of personal communication, clinical practice stressful, unpleasant feelings and humiliating experience that fortunately, in many cases reform and change.

  12. Construction and operation of the Spallation Neutron Source: Draft environmental impact statement. Volume 1

    International Nuclear Information System (INIS)

    1998-12-01

    DOE proposes to construct and operate a state-of-the-art, short-pulsed spallation neutron source comprised of an ion source, a linear accelerator, a proton accumulator ring, and an experiment building containing a liquid mercury target and a suite of neutron scattering instrumentation. The proposed Spallation Neutron Source would be designed to operate at a proton beam power of 1 megawatt. The design would accommodate future upgrades to a peak operating power of 4 megawatts. These upgrades may include construction of a second proton accumulation ring and a second target. The US needs a high-flux, short-pulsed neutron source to provide the scientific and industrial research communities with a much more intense source of pulsed neutrons for neutron scattering research than is currently available, and to assure the availability of a state-of-the-art facility in the decades ahead. This next-generation neutron source would create new scientific and engineering opportunities. In addition, it would help replace the neutron science capacity that will be lost by the eventual shutdown of existing sources as they reach the end of their useful operating lives in the first half of the next century. This document analyzes the potential environmental impacts from the proposed action and the alternatives. The analysis assumes a facility operating at a power of 1 MW and 4 MW over the life of the facility. The two primary alternatives analyzed in this EIS are: the proposed action (to proceed with building the Spallation Neutron Source) and the No-Action Alternative. The No-Action Alternative describes the expected condition of the environment if no action were taken. Four siting alternatives for the Spallation Neutron Source are evaluated: Oak Ridge National Laboratory, Oak Ridge, TN, (preferred alternative); Argonne National Laboratory, Argonne, IL (US); Brookhaven National Laboratory, Upton, NY; and Los Alamos National Laboratory, Los Alamos, NM

  13. Medical imaging

    International Nuclear Information System (INIS)

    Elliott, Alex

    2005-01-01

    Diagnostic medical imaging is a fundamental part of the practice of modern medicine and is responsible for the expenditure of considerable amounts of capital and revenue monies in healthcare systems around the world. Much research and development work is carried out, both by commercial companies and the academic community. This paper reviews briefly each of the major diagnostic medical imaging techniques-X-ray (planar and CT), ultrasound, nuclear medicine (planar, SPECT and PET) and magnetic resonance. The technical challenges facing each are highlighted, with some of the most recent developments. In terms of the future, interventional/peri-operative imaging, the advancement of molecular medicine and gene therapy are identified as potential areas of expansion

  14. The operational status of the Booster injector for the AGS accelerator complex at BNL

    International Nuclear Information System (INIS)

    Ahrens, L.; Bleser, E.; Brennan, J.M.; Gardner, C.; Gill, E.; Glenn, J.W.; Reece, K.; Roser, T.; van Asselt, W.; Weng, W.T.

    1992-01-01

    The Booster synchrotron at Brookhaven National Laboratory has been incorporated into the accelerator chain at the Alternating Gradient Synchrotron (AGS) complex. After a successful first commissioning effort in the spring of 1991, the Booster has been part of this year's silicon, gold and proton physics runs. After a brief review of the Booster design goals, and of the early commissioning, this paper will summarize this year's activities

  15. National synchrotron light source medical personnel protection interlock

    International Nuclear Information System (INIS)

    Buda, S.; Gmur, N.F.; Larson, R.; Thomlinson, W.

    1998-01-01

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated

  16. NATIONAL SYNCHROTRON LIGHT SOURCE MEDICAL PERSONNEL PROTECTION INTERLOCK

    Energy Technology Data Exchange (ETDEWEB)

    BUDA,S.; GMUR,N.F.; LARSON,R.; THOMLINSON,W.

    1998-11-03

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated.

  17. 21 CFR 872.4630 - Dental operating light.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental operating light. 872.4630 Section 872.4630...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4630 Dental operating light. (a) Identification. A dental operating light, including the surgical headlight, is an AC-powered device intended to illuminate...

  18. Measuring medication adherence in patients with incident hypertension: a retrospective cohort study.

    Science.gov (United States)

    Tang, Karen L; Quan, Hude; Rabi, Doreen M

    2017-02-13

    Though pharmacy claims data are commonly used to study medication adherence, there remains no standard operational definition for adherence especially for patients on multiple medications. Even when studies use the same terminology, the actual methods of calculating adherence can differ drastically. It is unclear whether the use of different definitions results in different conclusions regarding adherence and associated outcomes. The objective of our study was to compare adherence rates and associations with mortality using different operational definitions of adherence, and using various methods of handling concurrent medication use. We conducted a cohort study of patients aged ≥65 years from Manitoba, Canada, with incident hypertension diagnosed in 2004 and followed to 2009. We calculated adherence rates to anti-hypertensive medications using different operational definitions of medication adherence (including interval and prescription based medication possession ratios [MPR] and proportion of days covered [PDC]). For those on concurrent medications, we calculated adherence rates using the different methods of handling concurrent medication use, for each definition. We used logistic regression to determine the association between adherence and mortality for each operational definition. Among 2199 patients, 24.1% to 90.5% and 71.2% to 92.7% were considered adherent when using fixed interval and prescription-based interval medication possession ratios [MPRi and MPRp] respectively, depending on how concurrent medications were handled. Adherence was inversely associated with death, with the strongest association for MPRp measures. This association was significant only when considering adherence to any anti-hypertensive [aOR 0.70, 95% CI 0.51, 0.97], or when the mean of the class-specific MPRp's [adjusted OR 0.71, 95% CI 0.53, 0.95] was used. No significant association existed when the highest or lowest class-specific MPRp was used as the adherence estimate. The

  19. COMPUTATIONAL SCIENCE CENTER

    Energy Technology Data Exchange (ETDEWEB)

    DAVENPORT, J.

    2006-11-01

    Computational Science is an integral component of Brookhaven's multi science mission, and is a reflection of the increased role of computation across all of science. Brookhaven currently has major efforts in data storage and analysis for the Relativistic Heavy Ion Collider (RHIC) and the ATLAS detector at CERN, and in quantum chromodynamics. The Laboratory is host for the QCDOC machines (quantum chromodynamics on a chip), 10 teraflop/s computers which boast 12,288 processors each. There are two here, one for the Riken/BNL Research Center and the other supported by DOE for the US Lattice Gauge Community and other scientific users. A 100 teraflop/s supercomputer will be installed at Brookhaven in the coming year, managed jointly by Brookhaven and Stony Brook, and funded by a grant from New York State. This machine will be used for computational science across Brookhaven's entire research program, and also by researchers at Stony Brook and across New York State. With Stony Brook, Brookhaven has formed the New York Center for Computational Science (NYCCS) as a focal point for interdisciplinary computational science, which is closely linked to Brookhaven's Computational Science Center (CSC). The CSC has established a strong program in computational science, with an emphasis on nanoscale electronic structure and molecular dynamics, accelerator design, computational fluid dynamics, medical imaging, parallel computing and numerical algorithms. We have been an active participant in DOES SciDAC program (Scientific Discovery through Advanced Computing). We are also planning a major expansion in computational biology in keeping with Laboratory initiatives. Additional laboratory initiatives with a dependence on a high level of computation include the development of hydrodynamics models for the interpretation of RHIC data, computational models for the atmospheric transport of aerosols, and models for combustion and for energy utilization. The CSC was formed to

  20. The development of standard operating protocols for paediatric radiology

    International Nuclear Information System (INIS)

    Hardwick, J.; Mencik, C.; McLaren, C.; Young, C.; Scadden, S.; Mashford, P.; McHugh, K.; Beckett, M.; Calvert, M.; Marsden, P.J.

    2001-01-01

    This paper describes how the requirement for operating protocols for standard radiological practice was expanded to provide a comprehensive aide to the operator conducting a medical exposure. The protocols adopted now include justification criteria, patient preparation, radiographic technique, standard exposure charts, diagnostic reference levels and image quality criteria. In total, the protocols have been welcomed as a tool for ensuring that medical exposures are properly optimised. (author)