WorldWideScience

Sample records for oblique planar lymphoscintigraphy

  1. Sentinel Lymph Node Biopsy in Oral Cancer: Validation of Technique and Clinical Implications of Added Oblique Planar Lymphoscintigraphy and/or Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, J.B.; Soerensen, J.A.; Grupe, P.; Krogdahl, A. [Odense Univ. Hospital (Denmark). Depts. of Plastic and Reconstructive Surgery, Nuclear Medicine, and Pathology

    2005-10-01

    Purpose: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. Material and Methods: Forty patients (17 F and 23 M, aged 32-90) with 24 T1 and 16 T2 squamous cell carcinoma of the oral cavity. Planar lymphoscintigraphy, emission and transmission tomography were performed. Detection and excision of the sentinel nodes were guided by a gamma probe. The sentinel nodes were step-sectioning and stained with hematoxylin and eosin and cytokeratin (CK 1). Histology and follow-up were used as 'gold standard'. Tumor location, number of sentinel lymph nodes, metastasis, and recurrences were registered. Two observers evaluated the lymphoscintigraphic images to assess the inter-rater agreement. Results: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis ( P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel lymph node biopsy. Three patients developed a lymph node recurrence close to the primary tumor site during follow-up. Added oblique lymphoscintigraphic images and/or tomography revealed extra hotspots in 15/40 (38%) patients. In 4/40 (10%), extra contralateral hotspots were detected. Conclusion: Sentinel lymph node biopsy upstaged 28% of the patients. Sentinel lymph nodes close to the primary tumor were difficult to find. Added oblique planar images and/or tomographic images revealed extra clinical relevant hotspots in 38% of patients. Reproducibility proved excellent.

  2. Sentinel node lymphoscintigraphy in breast cancer: problems, solutions and clinical utility

    International Nuclear Information System (INIS)

    Wye, D.A.; Cohn, D.; Evans, S.G.; Larcos, G.; Ung, O.; Barry, P.

    1999-01-01

    Full text: Axillary lymph node status is an essential element in the staging of breast cancer. Recently, lymphatic mapping and sentinel node (SN) identification with lymphoscintigraphy has been promoted. The purposes of this study were to determine: (1) factors important in optimal identification of SNs preoperatively and (2) accuracy of SNs in predicting axillary lymph node status. Lymphoscintigraphy using 99 Tc m -antimony trisulphide colloid was performed in 35 patients before axillary dissection surgery. Four injections (20 MBq in 0.5 ml) were administered either around the biopsy cavity/scar or peritumorally. Sequential images in the anterior, anterior oblique and lateral projections were obtained until a SN was identified and in some patients delayed images (up to 15 h) were required. SNs were marked on the patient's skin in two planes. During surgery, a hand-held gamma probe was used to localize the marked SNs, which were removed prior to complete axillary dissection. Dissected lymph nodes were evaluated histopathologically for tumour involvement. To optimize SN identification, we found that breast cleaning post-injection, breast massage, imaging with arms both raised and lowered, and using different symbols to mark multiple SNs were necessary. In 32/35 patients (91%), a SN was successfully identified. Drainage patterns varied and were primarily to the axilla, internal mammary chain and intra clavicular areas. The SN appears to be an accurate predictor of axillary node status. In conclusion, breast lymphoscintigraphy is a simple procedure which appears to accurately identify sentinel nodes

  3. Cardiovascular lymphoscintigraphy

    International Nuclear Information System (INIS)

    Castronuovo, J.J. Jr.; Lopez-Majano, V.; Flanigan, P.; Schuler, J.J.; Jonasson, O.

    1983-01-01

    The technique of lymphoscintigraphy when applied to the heart and blood vessels correlates well with results of anatomic investigations of arterial and cardiac lymphatic vessels reported in the literature. Five dogs and eight rabbits underwent lymphoscintigraphy of the heart and aorta, as well as the iliac, femoral, and tibial arteries. After surgical exposure, approximately 500 microCi of /sup 99m/Tc-labelled antimony sulfide was injected into the myocardium or the adventitial-medial plane of an artery. The colloid particle size of 4 to 12 m mu causes resorption and transport only via the lymphatic vessels. Twenty-one preparations were imaged from 2 to 48 hours after administration. This method provides a functional demonstration that the tibial and femoral arteries of both species are invested with lymphatics. The first echelon of lymph nodes which drain muscular arteries are imaged within 2 hours. Regional lymph nodes could not be seen to drain the aorta or iliac arteries. Anterior left ventricular myocardial injection in the dog showed a single cardiac lymph node. This drainage pattern has been described previously by other investigators. In the rabbit a similarly placed injection visualized a group of regional cardiac nodes. Ligation of the collecting ducts afferent to the cardiac node in the dog prevented removal of the isotope from the heart at 3, 6, and 9 hours. At 24 hours the liver and spleen were imaged, the radiocolloid gaining entrance to the blood vascular system presumably via myocardial lymphaticovenous anastomoses. Lymphoscintigraphy reflects physiologic processes such as lymph transport, filtration, and reticuloendothelial function. It defines regional patterns of cardiac and arterial lymph drainage. It can confirm experimentally produced impairment of lymph drainage from a defined area of tissue. Lymphoscintigraphy should be useful in the investigation of the significance of lymph drainage to diseases of the heart and blood vessels

  4. Cardiovascular lymphoscintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Castronuovo, J.J. Jr.; Lopez-Majano, V.; Flanigan, P.; Schuler, J.J.; Jonasson, O.

    1983-08-01

    The technique of lymphoscintigraphy when applied to the heart and blood vessels correlates well with results of anatomic investigations of arterial and cardiac lymphatic vessels reported in the literature. Five dogs and eight rabbits underwent lymphoscintigraphy of the heart and aorta, as well as the iliac, femoral, and tibial arteries. After surgical exposure, approximately 500 microCi of /sup 99m/Tc-labelled antimony sulfide was injected into the myocardium or the adventitial-medial plane of an artery. The colloid particle size of 4 to 12 m mu causes resorption and transport only via the lymphatic vessels. Twenty-one preparations were imaged from 2 to 48 hours after administration. This method provides a functional demonstration that the tibial and femoral arteries of both species are invested with lymphatics. The first echelon of lymph nodes which drain muscular arteries are imaged within 2 hours. Regional lymph nodes could not be seen to drain the aorta or iliac arteries. Anterior left ventricular myocardial injection in the dog showed a single cardiac lymph node. This drainage pattern has been described previously by other investigators. In the rabbit a similarly placed injection visualized a group of regional cardiac nodes. Ligation of the collecting ducts afferent to the cardiac node in the dog prevented removal of the isotope from the heart at 3, 6, and 9 hours. At 24 hours the liver and spleen were imaged, the radiocolloid gaining entrance to the blood vascular system presumably via myocardial lymphaticovenous anastomoses. Lymphoscintigraphy reflects physiologic processes such as lymph transport, filtration, and reticuloendothelial function. It defines regional patterns of cardiac and arterial lymph drainage. It can confirm experimentally produced impairment of lymph drainage from a defined area of tissue. Lymphoscintigraphy should be useful in the investigation of the significance of lymph drainage to diseases of the heart and blood vessels.

  5. Thermal transport in oblique finned microminichannels

    CERN Document Server

    Fan, Yan; Singh, Pawan Kumar; Lee, Yong Jiun

    2015-01-01

    The main aim of this book is to introduce and give an overview of a novel, easy, and highly effective heat transfer augmentation technique for single-phase micro/minichannel heat sink. The specific objectives of the volume are to: Introduce a novel planar oblique fin microchannel and cylindrical oblique fin minichannel heat sink design using passive heat transfer enhancement techniques  Investigate the thermal transport in both planar and cylindrical oblique fin structures through numerical simulation and systematic experimental studies. Evaluate the feasibility of employing the proposed solution in cooling non-uniform heat fluxes and hotspot suppression Conduct the similarity analysis and parametric study to obtain empirical correlations to evaluate the total heat transfer rate of the oblique fin heat sink Investigate the flow mechanism and optimize the dimensions of cylindrical oblique fin heat sink Investigate the influence of edge effect on flow and temperature uniformity in these oblique fin chan...

  6. Lymphoscintigraphy and autologous stem cell implantation

    International Nuclear Information System (INIS)

    Peña, Yamile; Batista, Juan F.; Perera, Alejandro; Torres, Leonel A.; Sánchez, Elvia L.; Sánchez, Yolaine; Ducat, Luis; Prats, Anais; Hernández, Porfirio; Romero, Susana; Goicochea, Pedro; Quintela, Ana M.

    2016-01-01

    Lymphoscintigraphy is the criterion standard technique for the diagnosis of lymphedema. Advances of the application of autologous hematopoietic stem cells in ischemic disorders of lower limbs have increased the attention of researchers in this field. Aim: To determine the usefulness of lymphoscintigraphy for the assessment the efficacy of autologous stem cell implantation in patients with chronic lymphedema of the upper and lower limbs. Methods: Sixty-five patients were included. Clinical evaluation and lymphoscintigraphy were performed before and six months after stem cells implantation. The stem cells implantations were carried out by multiple superficial and deep injections in the trajectory of the lymphatic vessels and also in the inguinal region. A volume of 0.75 to 1.00 mL of cell suspension (1.0-2.2 x 109 stem cells) was administered in each injection site. Lymphoscintigraphy: Whole-body scans were acquired at 20 minutes, 1 hour, and 3 hours after administration of 185 to 259 MBq (5–7mCi) of 99m Tc-albumin nanocolloids in the interdigital space of both limbs. The anatomy and function of the lymphatic system were evaluated. Results: Functional assessment before implantation of stem cells showed that 69.2% of the patients had severe lymphatic insufficiency. The 61.5% of patients showed clinical improvement, confirmed by the results of the lymphoscintigraphy. The 46.1% of the cases evaluated showed a clear improvement. The study showed that the isotopic lymphography can evaluate the therapeutic response and its intensity. Conclusion: Lymphoscintigraphy is a useful technique for the evaluation and monitoring of autologous stem cell transplantation in patients with chronic lymphedema. (author)

  7. Lymphoscintigraphy in oncology: a rediscovered challenge

    Energy Technology Data Exchange (ETDEWEB)

    Valdes Olmos, R.A.; Hoefnagel, C.A. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Nuclear Medicine; Nieweg, O.E.; Jansen, L.; Rutgers, E.J.T.; Kroon, B.B.R. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Surgery; Borger, J. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Radiotherapy; Horenblas, S. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Urology

    1999-04-01

    The validation of the sentinel node concept in oncology has led to the rediscovery of lymphoscintigraphy. By combining preoperative lymphatic mapping with intraoperative probe detection this nuclear medicine procedure is being increasingly used to identify and detect the sentinel node in melanoma, breast cancer, and in other malignancies such as penile cancer and vulvar cancer. In the past lymphoscintigraphy has been widely applied for various indications in oncology, and in the case of the internal mammary lymph-node chain its current use in breast cancer remains essential to adjust irradiation treatment to the individual findings of each patient. In another diagnostic area, lymphoscintigraphy is also useful to document altered drainage patterns after surgery and/or radiotherapy; its use in breast cancer patients with upper limb oedema after axillary lymph-node dissection or in melanoma patients with lower-extremity oedema after groin dissection can provide information for physiotherapy or reconstructive surgery. Finally, the renewed interest in lymphoscintigraphy in oncology has led not only to the rediscovery of findings from old literature reports, but also to a discussion about methodological aspects such as tracer characteristics, image acquisition or administration routes, as well as to discussion on the study of migration patterns of radiolabelled colloid particles in the context of cancer dissemination. All this makes the need for standardized guidelines for lymphoscintigraphy mandatory. (orig.) With 10 figs., 1 tab., 56 refs.

  8. Rectal lymphoscintigraphy

    International Nuclear Information System (INIS)

    Bucci, L.; Salfi, R.; Meraviglia, F.; Mazzeo, F.

    1984-01-01

    Regional lymph nodes of the rectum are not demonstrable by pedal lymphoscintigraphy. The authors have evaluated the technique of rectal lymphoscintigraphy, using a technique similar to that which has been used in the assessment of lymph nodes in breast and prostatic cancer. Thirty-five patients were studied: ten normal subjects and 25 patients with rectal cancer. In normal subjects, the lymph nodes accompanying the superior hemorrhoidal artery and the inferior mesenteric artery are demonstrable in succession; after three hours the aortic lymph nodes are demonstrable. The 25 patients with rectal cancer underwent resection of their primary tumor and the stage was defined according to Dukes (1932). In five patients (stage A) no alteration was demonstrable. In 11 patients (stage B) the demonstration of regional lymph nodes was delayed vs. the control group. In nine cases (stage C) the demonstration of regional lymph nodes was delayed and defective versus the control group

  9. Comparison of Single-Photon Emission Computed Tomography-Computed Tomography (SPECT/CT) and Conventional Planar Lymphoscintigraphy for Sentinel Node Localization in Patients with Cutaneous Malignancies.

    Science.gov (United States)

    Doepker, Matthew P; Yamamoto, Maki; Applebaum, Matthew A; Patel, Nupur U; Jaime Montilla-Soler, M; Sarnaik, Amod A; Wayne Cruse, C; Sondak, Vernon K; Zager, Jonathan S

    2017-02-01

    Accurate preoperative lymphoscintigraphy is vital to performing sentinel lymph node biopsy (SLNB) for cutaneous malignancies. Potential advantages of single-photon emission computed tomography with integrated computed tomography (SPECT/CT) include the ability to readily identify aberrant drainage patterns as well as provide the surgeon with three-dimensional anatomic landmarks not seen on conventional planar lymphoscintigraphy (PLS). Patients with cutaneous malignancies who underwent SLNB with preoperative imaging using both SPECT/CT and PLS from 2011 to 2014 were identified. Both SPECT/CT and PLS were obtained in 351 patients (median age, 69 years; range, 5-94 years) with cutaneous malignancies (melanoma = 300, Merkel cell carcinoma = 33, squamous cell carcinoma = 8, other = 10) after intradermal injection of 99m technetium sulfur colloid (median dose 300 µCi). A mean of 4.3 hot spots were identified on SPECT/CT compared to 3.0 on PLS (p CT and PLS, while 172 (49 %) had additional hot spots identified on SPECT/CT compared to only 24 (6.8 %) additional on PLS. SPECT/CT demonstrated additional nodal basins in 103 patients (29.4 %), compared to only 11 patients (3.1 %) with additional basins on PLS. SPECT/CT is a useful adjunct that can help with sentinel node localization in challenging cases. It identified additional hot spots not seen on PLS in almost 50 % of patients. Because PLS identified hot spots not seen on SPECT/CT in 6.8 % of patients, we recommend using both modalities jointly. Long-term follow-up will be required to validate the clinical significance of the additional hot spots identified by SPECT/CT.

  10. Lymphoscintigraphy of draught horses with chronic progressive lymphoedema.

    Science.gov (United States)

    de Cock, H E V; Affolter, V K; Wisner, E R; Larson, R F; Ferraro, G L

    2006-03-01

    Early diagnosis of chronic progressive lymphoedema (CPL) may result in more effective interventions and provide a basis for further investigation of whether early diagnosis could be used as a means of eliminating potential genetic influences by cessation of breeding from affected individuals. Lymphoscintigraphy may be useful in draught horses to differentiate early lesions of CPL from other conditions in the pastern region. Forelimbs of 2 normal and 5 CPL-affected draught horses were evaluated with lymphoscintigraphy. Lymphoscintigraphy showed clearly the presence of interstitial fluid stasis and delayed lymphatic drainage in the affected extremities of diseased animals in contrast to normal animals of these breeds. The rate of decreased clearance of a particulate radiopharmaceutical from the tissues was related positively to the severity of clinical signs. Our findings support the hypothesis that lymph stasis is probably responsible for the progressive swelling and concurrent skin lesions observed in association with CPL in draught horses. Lymphoscintigraphy should also prove useful in diagnosis of CPL in draught horses, even in the mild stages of the disease; such early diagnosis may result in more effective intervention.

  11. The clinical application of lymphoscintigraphy for the diagnosis in hematological diseases

    International Nuclear Information System (INIS)

    Zhu Jun; Zhu Ruisen; Zhu Jifang; Jin Changqing; Yu Jianfang

    2000-01-01

    Results of lymphoscintigraphy in 78 patients with clinically suspected malignant lymphoma and leukemia were reported and its clinical value for in diagnosis of hematological diseases were evaluated. Confirmed by pathological examination, 30 cases were diagnosed as malignant lymphoma and 24 cases non-malignant lymphoma. In malignant lymphoma, the sensitivity of lymphoscintigraphy was 83.3% and the specificity 62.5%, where the sensitivity of CT and ultrasound, were 83.3%, 66.7% and 22.2% respectively. Confirmed by bone marrow biopsy, leukemia was found in 9 cases and non-leukemia in 15. In leukemia, the sensitivity of lymphoscintigraphy was 88.9% and specificity 53.3%. Whereas the sensitivity of CT, was 50%. Therefore, the lymphoscintigraphy have comparatively high sensitivity for the diagnosis of malignant lymphoma and leukemia

  12. Roles of preoperative lymphoscintigraphy for sentinel lymph node biopsy in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xiao; Liu Juanjuan; Wang Yongsheng; Wang Lei; Yang Guoren; Zhou Zhengbo; Li Yongqing; Liu Yanbing; Li Taiyu

    2010-01-01

    The objective of this study was to evaluate roles of preoperative lymphoscintigraphy for sentinel lymph node biopsy in breast cancer patients. Five hundred and sixty-five consecutive breast cancer patients were prospectively randomized into groups with or without preoperative lymphoscintigraphy. In a group with lymphoscintigraphy, 238 patients had sentinel lymph nodes spotted in lymphoscintigram. The visualization of sentinel lymph nodes in lymphoscintigram was not associated with patients' age, primary tumor size and location, histopathologic type and time interval from injection of radiocolloid to lymphoscintigraphy. However, patients with axillary metastasis had a lower identification rate of sentinel lymph nodes by lymphoscintigraphy than those without metastasis (P=0.003). The identification rate of axillary sentinel lymph nodes was 99.3% in the group and the rate was similar whether there was sentinel lymph nodes spotted in axillary in lymphoscintigram or not (99.6% vs. 98.1%, P=0.327). The false-negative rate in this group was 4.2%. While in a group without lymphoscintigraphy, the identification rate and the false-negative rate were 99.6% and 4.8%, respectively. There was no significant difference between the two groups in the identification rate of axillary sentinel lymph nodes (P=0.594) and in the false-negative rate (P=1.00). Preoperative lymphoscintigraphy could neither improve the identification rate nor reduce the false-negative rate of breast cancer sentinel lymph node biopsy, and it is not necessary for sentinel lymph node biopsy in breast cancer patients. (author)

  13. Lymphoscintigraphy and SPECT/CT in multicentric and multifocal breast cancer: does each tumour have a separate drainage pattern? Results of a Dutch multicentre study (MULTISENT)

    Energy Technology Data Exchange (ETDEWEB)

    Brouwer, O.R. [Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands); Antoni van Leeuwenhoekhospital, Amsterdam (Netherlands); Vermeeren, L.; Valdes Olmos, R.A. [Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands); Ploeg, I.M.C. van der; Rutgers, E.J.T.; Oldenburg, H.S.A. [Antoni van Leeuwenhoek Hospital, Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Loo, C.E. [Antoni van Leeuwenhoek Hospital, Department of Radiology, Netherlands Cancer Institute, Amsterdam (Netherlands); Pereira-Bouda, L.M.; Smit, F. [Rijnland Hospital, Department of Nuclear Medicine, Leiderdorp (Netherlands); Neijenhuis, P. [Rijnland Hospital, Department of Surgery, Leiderdorp (Netherlands); Vrouenraets, B.C. [Sint Lucas Andreas Hospital, Department of Surgery, Amsterdam (Netherlands); Sivro-Prndelj, F. [Sint Lucas Andreas Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Jap-a-Joe, S.M.; Borgstein, P.J. [Onze Lieve Vrouwe Gasthuis, Department of Nuclear Medicine, Amsterdam (Netherlands)

    2012-07-15

    To investigate whether lymphoscintigraphy and SPECT/CT after intralesional injection of radiopharmaceutical into each tumour separately in patients with multiple malignancies in one breast yields additional sentinel nodes compared to intralesional injection of the largest tumour only. Patients were included prospectively at four centres in The Netherlands. Lymphatic flow was studied using planar lymphoscintigraphy and SPECT/CT until 4 h after administration of {sup 99m}Tc-nanocolloid in the largest tumour. Subsequently, the smaller tumour(s) was injected intratumorally followed by the same imaging sequence. Sentinel nodes were intraoperatively localized using a gamma ray detection probe and vital blue dye. Included in the study were 50 patients. Additional lymphatic drainage was depicted after the second and/or third injection in 32 patients (64 %). Comparison of planar images and SPECT/CT images after consecutive injections enabled visualization of the number and location of additional sentinel nodes (32 axillary, 11 internal mammary chain, 2 intramammary, and 1 interpectoral. A sentinel node contained metastases in 17 patients (34 %)). In five patients with a tumour-positive node in the axilla that was visualized after the first injection, an additional involved axillary node was found after the second injection. In two patients, isolated tumour cells were found in sentinel nodes that were only visualized after the second injection, whilst the sentinel nodes identified after the first injection were tumour-negative. Lymphoscintigraphy and SPECT/CT after consecutive intratumoral injections of tracer enable lymphatic mapping of each tumour separately in patients with multiple malignancies within one breast. The high incidence of additional sentinel nodes draining from tumours other than the largest one suggests that separate tumour-related tracer injections may be a more accurate approach to mapping and sampling of sentinel nodes in patients with multicentric or

  14. Lymphoscintigraphy and SPECT/CT in multicentric and multifocal breast cancer: does each tumour have a separate drainage pattern? Results of a Dutch multicentre study (MULTISENT).

    Science.gov (United States)

    Brouwer, O R; Vermeeren, L; van der Ploeg, I M C; Valdés Olmos, R A; Loo, C E; Pereira-Bouda, L M; Smit, F; Neijenhuis, P; Vrouenraets, B C; Sivro-Prndelj, F; Jap-a-Joe, S M; Borgstein, P J; Rutgers, E J Th; Oldenburg, H S A

    2012-07-01

    To investigate whether lymphoscintigraphy and SPECT/CT after intralesional injection of radiopharmaceutical into each tumour separately in patients with multiple malignancies in one breast yields additional sentinel nodes compared to intralesional injection of the largest tumour only. Patients were included prospectively at four centres in The Netherlands. Lymphatic flow was studied using planar lymphoscintigraphy and SPECT/CT until 4 h after administration of (99m)Tc-nanocolloid in the largest tumour. Subsequently, the smaller tumour(s) was injected intratumorally followed by the same imaging sequence. Sentinel nodes were intraoperatively localized using a gamma ray detection probe and vital blue dye. Included in the study were 50 patients. Additional lymphatic drainage was depicted after the second and/or third injection in 32 patients (64%). Comparison of planar images and SPECT/CT images after consecutive injections enabled visualization of the number and location of additional sentinel nodes (32 axillary, 11 internal mammary chain, 2 intramammary, and 1 interpectoral. A sentinel node contained metastases in 17 patients (34%). In five patients with a tumour-positive node in the axilla that was visualized after the first injection, an additional involved axillary node was found after the second injection. In two patients, isolated tumour cells were found in sentinel nodes that were only visualized after the second injection, whilst the sentinel nodes identified after the first injection were tumour-negative. Lymphoscintigraphy and SPECT/CT after consecutive intratumoral injections of tracer enable lymphatic mapping of each tumour separately in patients with multiple malignancies within one breast. The high incidence of additional sentinel nodes draining from tumours other than the largest one suggests that separate tumour-related tracer injections may be a more accurate approach to mapping and sampling of sentinel nodes in patients with multicentric or

  15. DMSA SPECT imaging using oblique reconstruction in a paediatric population - benefits and technical considerations

    International Nuclear Information System (INIS)

    Parsons, G.; Ford, M.; Crisp, J.; Bernard, E.; Howman-Giles, R.

    1997-01-01

    Full text: DMSA renal scans are frequently requested for the diagnosis and follow-up of acute pyelonephritis and cortical scarring. This study was designed to:- 1. evaluate oblique reconstruction of DMSA SPECT over standard plane reconstruction and planar imaging; and 2. report on the technical aspects important in obtaining high quality DMSA SPECT, particularly in neonates. Over seven months, 210/231 (91 %) of DMSA scans were performed with SPECT on children from age nine days to 16 years, the median age being 2.5 years. 65 patients (31 %) were under one year and 39 (18%) were under six months. Planar and SPECT imaging with standard plane reconstruction and oblique reorientation was performed on the Siemens triple-headed gamma camera. High quality SPECT images were obtained on the smallest babies using a paediatric palette, and were of comparable quality to those of older children. At the time of reporting, the nuclear medicine physician assessed the diagnostic value of the three types of date presented: (1) planar images; (2) standard plane SPECT reconstruction; and (3) oblique SPECT reconstruction. Cortical defects were identified separately for upper, middle and lower poles. Three physicians concluded that high quality SPECT is superior to planar images when assessing the renal cortex. In addition, oblique reorientation is superior to standard reconstruction, particularly at the upper and lower poles. SPECT is now performed routinely on patients of all ages, and the oblique sagittal and coronal reorientation is now used in place of the standard reconstruction

  16. Feasibility of sentinel node lymphoscintigraphy in stage I testicular cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Pieter J.; Nieweg, Omgo E. [Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Horenblas, Simon [Department of Urology, Netherlands Cancer Institute, Amsterdam (Netherlands); Olmos, Renato Valdes A.; Hoefnagel, Cornelis A. [Department of Nuclear Medicine, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2002-05-01

    The aim of this study was to investigate the feasibility of lymphoscintigraphy for sentinel node identification in testicular cancer. Five patients with clinical stage I testicular cancer were prospectively included. A single dose of technetium-99m nanocolloid (mean dose 99 MBq, volume 0.2 ml) was injected into the funiculus in the first patient and into the testicular parenchyma in the following four patients. Dynamic lymphoscintigraphy was performed over 10 min, followed by early and late static images after 15 min and 2 to 24 h, respectively. Lymphoscintigraphy was followed by laparoscopic sentinel node biopsy on the same day in the last two patients using patent blue dye and an endoscopic gamma probe. The funicular administration route showed five hot spots in the right inguinal region after 2 h. Intratesticular administration resulted in sentinel node visualisation in three of the four patients. Dynamic images showed afferent lymphatic vessels to one sentinel node in the left para-aortic region in two patients and two sentinel nodes in the left para-aortic region in another patient. Sentinel nodes were intraoperatively identified in one of two patients who underwent laparoscopic exploration. It is concluded that lymphoscintigraphy for sentinel node identification is feasible in stage I testicular cancer using intratesticular radiocolloid administration. (orig.)

  17. The edema of the lower limb: investigations by dynamic and static lymphoscintigraphy

    International Nuclear Information System (INIS)

    Fritz, P.; Wildeshaus, K.H.; Winkel, K. zum.

    1986-01-01

    24 patients with edema of the lower limb after femoro-popliteal or femoro-crural bypass surgery were investigated by dynamic and static lymphoscintigraphy. In 20 patients contrast phlebography was also done. Venous drainage disturbences were not demonstrable. Legs with edema had a statistically significant lower drainage capacity for sup(99m)Tc sulfur microcolloid than contralateral legs. Velocity of prefascial lymphatic transport of radioactivity showed no significant differences between edematous and contralateral legs. Static lymphoscintigraphy demonstrated typical lymphedema associated-soft tissue findings in 83%. Diffuse retention of radiocolloid in the region of the edema and iatrogenic lesions of lymph vessels (dermal back flow) in the region of the surgical scar were found in 45% and 41% of cases, respectively. Based on the criteria of dynamic and static lymphoscintigraphy and the pathogenetic classification of lymphedema according to FOELDI, a dynamic insufficiency of lymph drainage must be assumed to be the cause of lymphedema after arterial reconstructions. Iatrogenic lymph vessel lesions also play a causative role. Dynamic and static lymphoscintigraphy gives valuable information for the differentiation between postreconstructive lymphedema of mechanical and functional origin. (Author)

  18. Subwavelength image manipulation through oblique and herringbone layered acoustic systems

    International Nuclear Information System (INIS)

    Li, Chunhui; Jia, Han; Ke, Manzhu; Li, Yixiang; Liu, Zhengyou

    2014-01-01

    In this paper, an oblique and a herringbone layered acoustic structure are experimentally and theoretically demonstrated to manipulate acoustic subwavelength images. An imaging resolution of less than one tenth of a wavelength is achieved with both optimized systems, and lateral image shift has been realized by an oblique layered system. The thicknesses of both the oblique and the herringbone layered acoustic systems are largely reduced through utilizing the oblique or herringbone wave propagation path instead of the vertical wave propagation path in the rectangular layered planar acoustic system. With smaller size and subwavelength image manipulation, the acoustic systems are more favourable for practical application. (paper)

  19. Lymphoscintigraphy in the diagnosis of extremity lymphedema

    International Nuclear Information System (INIS)

    Yang Meifang; Lu Gang; Li Fang; Tian Jian

    1994-01-01

    Lymphoscintigraphy, using 99m Tc labeled antimony sulfur colloid and 99m Tc labeled dextran, was performed on 25 patients with swelling of upper or lower extremities for diagnosis of lymphedema. Five different lymphoscintigraphic patterns were identified, that is normal (4 cases), collaterals (2 cases), mixed (13 cases), dermal backflow (4 cases) and no backflow pattern (2 cases). Eight patients underwent operations for lympho-venous anastomoses on the involved extremity. The results indicate that lymphoscintigraphy has many advantages, such as simplicity and non-invasiveness, safety and reliability, being able to differentiate properties of extremity edema, to provide the information of morphologic changes and dynamically display lymphatic drainage and obstructive extent in the lymphatic system. The procedure is valuable for determination of the treatment modalities and the selection of patient for lymphatic microsurgery

  20. Lymphoscintigraphy and intra-operative gamma probe in detection of sentinel lymph node for breast cancer surgery

    International Nuclear Information System (INIS)

    Le Ngoc Ha; Le Manh Ha; Bui Quang Bieu

    2011-01-01

    Sentinel lymph node biopsy (SLNB) has been emerged as a highly accurate method of axillary staging in management of breast cancer patients. Sentinel lymph node detection (SLND) by lymphoscintigraphy and intra-operative gamma probe for SLNB have been widely used in the world. Objectives: the purpose of our study was to evaluate the result of techniques using lymphoscintigraphy and intra-operative gamma probe for SLND in breast carcinoma patients. Materials and Methods: 102 patients with early breast carcinoma were enrolled in the study. Lymphoscintigraphy using Tc-99m-human serum albumin colloid, intra-operative gamma probe were undergone for localization and SLNB. Total axillary lymph node was dissected in breast cancer surgery. Results: The success rate of lymphoscintigraphy and SLND was 98.0% (100/102 patients), mean number of sentinel lymph node (SLN)/patient was 1.56 ± 0.79 (ranged 1 - 3), number of lymphatic vessel/SLN was 1.5 ± 0.69 (ranged 1 - 4) and mean time for SLND on lymphoscintigraphy was 4.21 ± 13.4 minutes (2 - 15 minutes). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of radio-guided SLNB for axillary staging was 100%, 70.6%, 41.2%, 100% and 75.6 % respectively. Conclusions: radio-guided SLNB by lymphoscintigraphy and intra-operative gamma probe is feasible and reliable for axillary staging in early breast carcinoma patients. (author)

  1. Penile lymphoscintigraphy for sentinel node identification

    Energy Technology Data Exchange (ETDEWEB)

    Valdes Olmos, R.A.; Hoefnagel, C.A. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Nuclear Medicine; Tanis, P.J.; Jansen, L.; Nieweg, O.E. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Surgery; Meinhardt, W.; Horenblas, S. [Netherlands Cancer Inst., Amsterdam (Netherlands). Dept. of Urology

    2001-05-01

    Lymphoscintigraphy for sentinel node (SN) identification has been extensively validated in breast cancer and melanoma. The aim of this study was to evaluate the findings of lymphoscintigraphy for SN identification in carcinoma of the penis. Lymphoscintigraphy was performed in 74 consecutive patients (mean age 62.2 years, range 28-87 years) with clinically lymph node-negative squamous cell carcinoma of the penis (stage T2 or greater). Following local anaesthesia by xy-locaine 10% spray, technetium-99m nanocolloid (mean dose 64.8 MBq, range 40-131 MBq) in a volume of 0.3-0.4 ml was injected intradermally around the tumour. Shortly after injection, a 20-min dynamic study was performed with a dual-head gamma camera; subsequently, static anterior and lateral images were obtained at 30 min and 2 h using simultaneous cobalt-57 flood source transmission scanning. {sup 57}Co-assisted skin marking defined SN location for gamma probe/blue dye-guided biopsy, which was performed the next day. The SN visualization rate was 97% (72/74). Lymphatic drainage was bilateral in 81% of the cases (58/72), exclusively to the left groin in 13% (9/72) and only to the right groin in 6%. Bilateral lymph node drainage was synchronous in 38% (22/58) and asynchronous in 62% (in 18 patients the initial route was the left groin, and in the other 18, the right groin). Visualization before 30 min occurred in 66 patients (93%), in 64 of them (88%) already during the dynamic study. A total of 173 SNs were visualized (85 in the right groin, 88 in the left groin). Pitfalls were caused by inguinal skin contamination during injection (four patients) and intracavernous administration (one patient). At surgery, a total of 161 SNs were identified and removed. Sixteen patients (22%) had a tumour-positive SN and underwent standard regional lymph node dissection subsequently. During follow-up (median 28 months, range 3-74 months), two patients with a negative SN developed lymph node metastases in the mapped

  2. Penile lymphoscintigraphy for sentinel node identification

    International Nuclear Information System (INIS)

    Valdes Olmos, R.A.; Hoefnagel, C.A.; Tanis, P.J.; Jansen, L.; Nieweg, O.E.; Meinhardt, W.; Horenblas, S.

    2001-01-01

    Lymphoscintigraphy for sentinel node (SN) identification has been extensively validated in breast cancer and melanoma. The aim of this study was to evaluate the findings of lymphoscintigraphy for SN identification in carcinoma of the penis. Lymphoscintigraphy was performed in 74 consecutive patients (mean age 62.2 years, range 28-87 years) with clinically lymph node-negative squamous cell carcinoma of the penis (stage T2 or greater). Following local anaesthesia by xy-locaine 10% spray, technetium-99m nanocolloid (mean dose 64.8 MBq, range 40-131 MBq) in a volume of 0.3-0.4 ml was injected intradermally around the tumour. Shortly after injection, a 20-min dynamic study was performed with a dual-head gamma camera; subsequently, static anterior and lateral images were obtained at 30 min and 2 h using simultaneous cobalt-57 flood source transmission scanning. 57 Co-assisted skin marking defined SN location for gamma probe/blue dye-guided biopsy, which was performed the next day. The SN visualization rate was 97% (72/74). Lymphatic drainage was bilateral in 81% of the cases (58/72), exclusively to the left groin in 13% (9/72) and only to the right groin in 6%. Bilateral lymph node drainage was synchronous in 38% (22/58) and asynchronous in 62% (in 18 patients the initial route was the left groin, and in the other 18, the right groin). Visualization before 30 min occurred in 66 patients (93%), in 64 of them (88%) already during the dynamic study. A total of 173 SNs were visualized (85 in the right groin, 88 in the left groin). Pitfalls were caused by inguinal skin contamination during injection (four patients) and intracavernous administration (one patient). At surgery, a total of 161 SNs were identified and removed. Sixteen patients (22%) had a tumour-positive SN and underwent standard regional lymph node dissection subsequently. During follow-up (median 28 months, range 3-74 months), two patients with a negative SN developed lymph node metastases in the mapped basin

  3. The lymphoscintigraphy and intraoperative gamma detection of sentinel lymph node in oral cavity carcinoma

    International Nuclear Information System (INIS)

    Zhao Xinming; Zhang Jingmian; Wang Jianfang; Li Dezhi; Sun Li; Dai Chunnuan; He Yang

    2006-01-01

    Objective: To evaluate the role of lymphoscintigraphy and intraoperative gamma probe detection of sentinel lymph node (SLN) in oral cavity carcinoma. Methods: 99 Tc m labeled dextran (DX) was injected submucously at the center of oral cavity carcinoma before operation. The SLN identified by lymphoscintigraphy and intraoperative gamma counter probe were dissected out from the exited tissue. All sentinel and other lymph nodes were sent for pathological examination. Results: In all 33 cases, SLN and other lymph nodes were clear identified by lymphoscintigraphy. Forty-three SLNs were seen, among them 1 in 25 cases, 2 in 6 cases and 3 in 2 cases. Metastases were detected by biopsy in SLN in 9 cases, however, 11 cases showed positive neck lymph node metastases. The sensitivity of SLN gamma detection was 100% and in biopsy sensitivity was 81.82%, accuracy was 93.94%, false positive rate was 0, and false negative rate was 18.18%. Conclusions: Intraoperative gamma probe detection is the reliable approach to identify SLN in oral cavity carcinoma. Lymphoscintigraphy is the base of localization for oral cavity carcinoma. (authors)

  4. Role of lymphoscintigraphy in diagnosis and management of patients with leg swelling of unclear etiology

    International Nuclear Information System (INIS)

    Kalawat, Tek Chand; Chittoria, Ravi Kumar; Reddy, Praveen Kumar; Suneetha, Batchu; Narayan, Ravishwar; Ravi, Parthsarthi

    2012-01-01

    To study the utility of lymphoscintigraphy in detection of lymphatic obstruction in patients with leg swelling of unclear etiology, selection of site for nodo venous shunt procedure, and follow-up lymphoscintigraphic documentation of improved lymph flow in surgically treated limb. Twenty four consecutive patients with leg swelling, 10 male, 14 female with mean age 47 years, range from 13 years to 74 years underwent lymphoscintigraphy. All patients were referred from Department of Plastic Surgery, after initial work-up, and routine investigations to rule out the other causes of leg swelling. Both clinical and scintigraphic staging performed for all patients. All clinically and scintigraphically positive patients treated with decongestive lymphatic therapy (DLT). In addition to the DLT, those patients positive for unilateral or bilateral lymphedema, consented for surgical intervention, nodo venous shunt (NVS) in their only affected or one of the two affected lower limbs. Follow-up lymphoscintigraphy performed in operated cases after 3 months to 6 months of surgery, lymphoscintigraphy images of each patient in pre and post-surgery compared. In 20/24 cases (83%) of clinically positive leg swelling were found to be positive for lymphedema on lymphoscintigraphy and remaining, 4/24 were scintigraphically normal. Based on the clinical and lymphoscintigraphy staging, 03/20 cases (15%) had Grade I lymphedema, 01/20 (5%) Grade II lymphedema, 06/20 (30%) Grade III and remaining 10/20 (50%) had Grade IV lymphedema. 11/20 cases of Lymphedema (55%) were managed conservatively by only DLT and in remaining 09/20 cases (45%), who were case of Grade IV, lymphedema (five patients with unilateral and four patients with bilateral disease) initially treated with DLT, and on completion of DLT, undergone for NVS procedure, in their unilaterally affected lower limb or one of the two diseased lower limbs. All nine patients showed remarkable clinical improvement in leg swelling and their

  5. Breast cancer lymphoscintigraphy: Factors associated with sentinel lymph node non visualization.

    Science.gov (United States)

    Vaz, S C; Silva, Â; Sousa, R; Ferreira, T C; Esteves, S; Carvalho, I P; Ratão, P; Daniel, A; Salgado, L

    2015-01-01

    To evaluate factors associated with non identification of the sentinel lymph node (SLN) in lymphoscintigraphy of breast cancer patients and analyze the relationship with SLN metastases. A single-center, cross-sectional and retrospective study was performed. Forty patients with lymphoscintigraphy without sentinel lymph node identification (negative lymphoscintigraphy - NL) were enrolled. The control group included 184 patients with SLN identification (positive lymphoscintigraphy - PL). Evaluated factors were age, body mass index (BMI), tumor size, histology, localization, preoperative breast lesion hookwire (harpoon) marking and SLN metastases. The statistical analysis was performed with uni- and multivariate logistic regression models and matched-pairs analysis. Age (p=0.036) or having BMI (p=0.047) were the only factors significantly associated with NL. Being ≥60 years with a BMI ≥30 increased the odds of having a NL 2 and 3.8 times, respectively. Marking with hookwire seems to increase the likelihood of NL, but demonstrated statistical significance is lacking (p=0.087). The other tested variables did not affect the examination result. When controlling for age, BMI and marking with the harpoon, a significant association between lymph node metastization and NL was not found (p=0.565). The most important factors related with non identification of SLN in the patients were age, BMI and marking with hook wire. However, only the first two had statistical importance. When these variables were controlled, no association was found between NL and axillary metastases. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  6. The value of imaging in standing position in preoperative breast lymphoscintigraphy.

    Science.gov (United States)

    Anagnostou, Christos; Baiocco, Cinzia; Arnulfo, Alberto; Liberatore, Mauro; Baccheschi, Anna Maria; Inglese, Eugenio

    2011-08-01

    Breast lymphoscintigraphy is an accurate technique, but in a minority of cases the sentinel node (SN) visualization cannot be achieved or can be very difficult. We evaluated the potential clinical advantages and limitations of performing imaging in the standing position. The aim was to establish if this examination modality is quicker and helpful in the presence of "hidden" SN, checking also for any influence of SN skin landmarking in the upright position on the correct intraoperative SN identification. The overall objective was to verify if the standing position can be routinely used in breast lymphoscintigraphy. A total of 144 patients underwent lymphoscintigraphy in both standing and supine positions. In both modalities, a skin landmark was set coincident with the SN orthogonal projections. The acquisition times of 2 groups (each consisting of 45 patients) examined with the standing or supine acquisition modality, were compared. In 6 cases with hidden SN and in 34 cases with difficult or partial visualization in one of the supine views, the standing protocol was effective and led to better and quicker visualization of lymph nodes (median examination time: 25.5 minutes standing, 35.5 minutes supine). Significant differences in skin landmark position between the 2 modalities were present only in overweight patients and in large breasts. This, however, did not have a negative impact on successful intraoperative localization of SN with the gamma probe. Standing acquisition resulted to be a faster, easier, and more accurate examination protocol and can be used as the routine method for SN detection in breast lymphoscintigraphy.

  7. Visualization of the thoracic duct by lymphoscintigraphy

    International Nuclear Information System (INIS)

    Baulieu, F.; Baulieu, J.L.; Itti, R.; Tours Univ., 37

    1987-01-01

    Imaging of the thoracic duct is usually performed by radiological lymphography. However, this procedure, which uses an oil based dye injected directly into the lymph channels, has some adverse effects. In this paper we note that lymphoscintigraphy, a physiological and non invasive method, may visualize thoracic duct abnormalities, and might be particularly usefull when radiological lymphography is contraindicated. (orig.)

  8. Pelvic lymphoscintigraphy: contribution to the preoperative staging of rectal cancer

    International Nuclear Information System (INIS)

    Silva, Jose Hyppolito da

    1996-01-01

    Preservation of the lower rectal sphincters has been the main concern of colorectal surgeons in an attempt to avoid colostomy. Various proposed procedures contradict the oncological principles of the operation's radicality, especially pelvic lymphadenectomy. Prior knowledge of this space is therefore, an important factor in choosing the operative technique: radical (amputation), or conservative. The introduction of ultrasound, computed tomography and magnetic resonance imaging, have provided preoperative information about the anatomic nature of the region. The morphological and functional study supplied by lymphoscintigraphy of this space supplements the data furnished by the other imaging techniques. The objective of this prospective of this prospective study was threefold: to standardize lymphoscintigraphy, to differentiate patients with rectal cancer from those with other coloproctological diseases and to asses the lymphonodal involvement in the former by utilizing the anatomopathological and surgical correlation. The study included 60 patients with various coloproctological diseases seen on the Department of Gastroentorology, Hospital da Clinicas, University of Sao Paulo School of Medicine, from September 1990 to August 1993. Thirty were cases of rectal cancer and the remainder were other colorectal diseases. The method consisted of injecting 0.5 of a dextran solution market with radioactive technetium in the perineal region and obtaining images by a gamma camera. In the rectal cancer patients, the tracer progresses unilaterally or is absent; in the others, it is bilateral and symmetrical, although its progress may be slow. The statistical data demonstrated that in rectal cancer, lymphoscintigraphy asseses the nodal involvement approximaltely as that obtained by the sun of the anatomapathological and surgical findings. Based on the results, the following conclusioons were possible: lymphoscintigraphy is a standardized, painless and harmless test that can be

  9. Radionuclide lymphoscintigraphy in limb edemas; La lymphoscintigraphie dans la pathologie lymphatique des membres: reflexions apres 20 ans d`utilisation

    Energy Technology Data Exchange (ETDEWEB)

    Pecking, A.P. [Centre Rene Huguenin, 92 - Saint-Cloud (France); Cluzan, R.V. [Hopital Cognacq-Jay, 75 - Paris (France)

    1997-12-31

    Indirect radionuclide lymphoscintigraphy is a safe, non-invasive and physiological method for the assessment of the limb lymphatic system. Colloids as antimony or rhenium sulphide labeled with 99m technetium have been widely used for morphological studies. Quantitative studies involving a continuous count rate monitoring of the injection sites followed by a computer analysis of dynamic image sequences have been a new promising step for an objective measurement of the peripheral lymphatic function. The injection site is always bilateral on the first web space of either the hand or the foot using a small volume (<0.2 mL) of the radiocolloid. This method has been validated on 30 young healthy volunteers and normal values established from a group of 125 upper and 141 lower limbs (normal subjects). The normal results showed a slight but continuous decrease in lymphatic function depending on the age of the subject. In pathological situations, we observed dysfunction of the lymphatic system in pure lymphoedemas or so-called lympho-venous edemas as demonstrated on the 1,182 upper and 2,463 lower limbs tested. The radionuclide lymphoscintigraphy may be helpful in cases of unilateral swollen limbs demonstrating a lymphatic dysfunction on a clinically normal contralateral limb at the first stage of a distal edema which appears within a few weeks or days, in a transient edema phase when normal status and oedema alternate. The lymphoscintigraphy gives objective and reproducible parameters necessary to assess the lymphatic variation under therapy (decongestive physiotherapy, surgery, drugs) and may be useful in the selection of new lympho-tonic treatments. This method is only reflecting the lymphatic function and is unable to appreciate the total lymphatic flow of the limb. Its results only reflect what happens at the injection site and it may be necessary to add a second test using a proximal injection in order to assess the occurrence of lymph nodes not visualized by the

  10. Correlation of number and identification of sentinel nodes during radiographer led lymphoscintigraphy prior to sentinel lymph node biopsy in breast cancer patients

    International Nuclear Information System (INIS)

    Camilleri, Gail; Borg Grima, Karen; Zarb, Francis

    2012-01-01

    Purpose: The sentinel lymph node biopsy (SLNB) concept using the cutaneous (subdermal) peri-areolar approach is rapidly emerging as the technique for axillary staging in breast cancer. The procedure indicates whether axillary lymph node dissection (ALND) is necessary, therefore drastically minimising the invasiveness of surgical treatment. The SLNB concept is based on evidence suggesting that malignant disease primarily affects the sentinel node (SN) before being disseminated into the axillary lymph nodes (ALNs). Objective: This study was to define the role of lymphoscintigraphy in the visualisation of SNs during SLNB and to establish the correlation between the number of SNs identified on lymphoscintigraphy to the number of surgically identified SNs. Method: The study was a non-experimental, correlation study utilising quantitative data. Lymphoscintigraphy reports and histology results of 55 female breast cancer patients who underwent SLNB with partial or total back-up ALND, were retrospectively evaluated. Results: A maximum of 2 and a minimum of 0 sentinel nodes were visualised on lymphoscintigraphy in 52 out of 55 patients. Successful lymphoscintigraphy was highly predictive (p ≤ 0.001) of a successful SLNB as all 52 patients (94.5%) proceeded to have successful SN/s identification. There was a significant association (p ≤ 0.05) between the number of SN/s visualised on lymphoscintigraphy and the number of SN/s identified during SLNB. Lymphoscintigraphy accurately predicted the number of surgically identified SNs in 50.91% of cases (28/55). Conclusion: Considering that successful imaging effectively assures SN identification, the routine use of lymphoscintigraphy using the subdermal peri-areolar approach is fundamental in the reliable performance of SLNB.

  11. The value of lymphoscintigraphy for cervical sentinel lymph node detection in patients with clinically N0 oral squamous cell carcinoma

    International Nuclear Information System (INIS)

    Liu Sheng; Jiang Ningyi; Lu Xianping; Liang Jiugen

    2005-01-01

    Objective: To evaluate the value of lymphoscintigraphy for cervical sentinel lymph node (SLN) detection in patients with oral squamous cell carcinoma. Methods: Twenty-one patients with clinically N 0 oral squamous carcinoma underwent preoperative lymphoscintigraphy and intraoperative methylene blue location. The results were compared with pathological findings. Results: 1) The sensitivity of lymphoscintigraphy for detecting SLN was 100%(21/21), and methylene blue was 85% (17/20). 2)Both SLN biopsy and cervical ablative dissection confirmed that 33.3% (7/21) patients were with cervical lymph node metastasis. Fourteen non-metastatic SLNs comfirmed by biopsy were also proved with the findings of neck dissection, and the specificity was 100%. Conclusion: Lymphoscintigraphy can detect the cervical SLN and accurately predict cervical lymph node metastasis in patients with oral squamous cell carcinoma.(authors)

  12. Correlation between theoretical anatomical patterns of lymphatic drainage and lymphoscintigraphy findings during sentinel node detection in head and neck melanomas

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Monica; Ruiz, Diana Milena [Hospital Clinic de Barcelona, Nuclear Medicine Department, Barcelona (Spain); Vidal-Sicart, Sergi; Paredes, Pilar; Pons, Francesca [Hospital Clinic de Barcelona, Nuclear Medicine Department, Barcelona (Spain); Institut d' Investigacions Biomediques Agusti Pi i Sunyer (IDIBAPS), Barcelona (Spain); Torres, Ferran [Hospital Clinic Barcelona, Statistical of Biostatistics and Data Management Core Facility, IDIBAPS, Barcelona (Spain); Universitat Autonoma de Barcelona, Biostatistics Unit, Faculty of Medicine, Barcelona (Spain)

    2016-04-15

    In the diagnosis of head and neck melanoma, lymphatic drainage is complex and highly variable. As regional lymph node metastasis is one of the most important prognostic factors, lymphoscintigraphy can help map individual drainage patterns. The aim of this study was to compare the results of lymphoscintigraphy and sentinel lymph node (SLN) detection with theoretical anatomical patterns of lymphatic drainage based on the location of the primary tumour lesion in patients with head and neck melanoma. We also determined the percentage of discrepancies between our lymphoscintigraphy and the theoretical location of nodal drainage predicted by a large lymphoscintigraphic database, in order to explain recurrence and false-negative SLN biopsies. In this retrospective study of 152 patients with head and neck melanoma, the locations of the SLNs on lymphoscintigraphy and detected intraoperatively were compared with the lymphatic drainage predicted by on-line software based on a large melanoma database. All patients showed lymphatic drainage and in all patients at least one SLN was identified by lymphoscintigraphy. Of the 152 patients, 4 had a primary lesion in areas that were not described in the Sydney Melanoma Unit database, so agreement could only be evaluated in 148 patients. Agreement between lymphoscintigraphic findings and the theoretical lymphatic drainage predicted by the software was completely concordant in 119 of the 148 patients (80.4 %, 95 % CI 73.3 - 86 %). However, this concordance was partial (some concordant nodes and others not) in 18 patients (12.2 %, 95 % CI 7.8 - 18.4 %). Discordance was complete in 11 patients (7.4 %, 95 % CI 4.2 - 12.8 %). In melanoma of the head and neck there is a high correlation between lymphatic drainage found by lymphoscintigraphy and the predicted drainage pattern and basins provided by a large reference database. Due to unpredictable drainage, preoperative lymphoscintigraphy is essential to accurately detect the SLNs in head and

  13. Lymphoscintigraphy for sentinel lymph node detection in breast cancer: usefulness of image truncation

    International Nuclear Information System (INIS)

    Carrier, P.; Remp, H.J.; Chaborel, J.P.; Lallement, M.; Bussiere, F.; Darcourt, J.; Lallement, M.; Leblanc-Talent, P.; Machiavello, J.C.; Ettore, F.

    2004-01-01

    The sentinel lymph node (SNL) detection in breast cancer has been recently validated. It allows the reduction of the number of axillary dissections and their corresponding side effects. We tested a simple method of image truncation in order to improve the sensitivity of lymphoscintigraphy. This approach is justified by the magnitude of uptake difference between the injection site and the SNL. We prospectively investigated SNL detection using a triple method (lymphoscintigraphy, blue dye and surgical radio detection) in 130 patients. SNL was identified in 104 of the 132 patients (80%) using the standard images and in 126 of them (96, 9%) using the truncated images. Blue dye detection and surgical radio detection had a sensitivity of 76,9% and 98,5% respectively. The false negative rate was 10,3%. 288 SNL were dissected, 31 were metastatic. Among the 19 patients with metastatic SNL and more than one SNL detected, the metastatic SNL was not the hottest in 9 of them. 28 metastatic SNL were detected Y on truncated images versus only 19 on standard images. Truncation which dramatically increases the sensitivity of lymphoscintigraphy allows to increase the number of dissected SNL and probably reduces the false negative rate. (author)

  14. Prevalence and clinical significance of supra- or infraclavicular drainage on preoperative lymphoscintigraphy in women with breast cancer.

    Science.gov (United States)

    Tanaka, T; Sato, S; Tada, A; Inai, R; Taira, N; Doihara, H; Kanazawa, S

    2016-06-01

    Preoperative sentinel lymph node (SLN) mapping by lymphoscintigraphy is helpful to evaluate extra-axillary SLNs over a wider range than the blue dye method. However, the clinical value of extra-axillary SLNs remains uncertain. The goal of this study was to determine the prevalence and clinical significance of supra- or infraclavicular drainage on preoperative lymphoscintigraphy in women with breast cancer. We retrospectively reviewed the files of 942 consecutive breast cancer women who underwent preoperative lymphoscintigraphy for SLN biopsy at our institution between April 2004 and March 2015. Supra- or infraclavicular drainage was detected in 5/942 women (0.5%) on preoperative lymphoscintigraphy. An axillary hot spot was detected in all five women, and a positive axillary SLN was detected in four women. Breast tumor locations were the upper inner or outer quadrants in four women and the lower outer quadrant in one woman. The median follow-up period was 75 months (mean: 92; range: 26-111 months). Recurrence outside the axilla was found in three (60%) women. The woman with a negative SLN status did not undergo adjuvant chemotherapy, but developed extra-axillary lymph node recurrence 3 years after primary surgery. No patient died of metastatic breast cancer at the last follow-up. The detection of the supra- or infraclavicular SLNs on lymphoscintigraphy may provide additional staging information to tailor individual treatment regimens with regard to the potential risk of recurrence or metastasis of breast cancer. Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  15. Production of 99mTc-anatomy sulfide colloid for lymphoscintigraphy

    International Nuclear Information System (INIS)

    Shabani, G. A.; Hamzeh, H.; Najafi, R.

    2002-01-01

    The lymphatic system provides one of the chief paths for the spread (metastasis) of cancer from one part of body to another. Hodgkin's diseases, lymphocytic leukemia, various metastatic diseases and many lymph ode disorders can be assessed by lymphoscintigraphy. Radionuclide lymphoscintigraphy has been used for many years to define the lymphatic drainage of melanoma. The most common radiopharmaceuticals used for lymphoscintigraphy are 99 mTc-Sc, 99 mTc-antimony sulfide colloid has been chosen between other colloids. For antimony sulfide colloid preparation, hydrogen sulfide gas was passed through D.E. until saturation. Antimony potassium tartrate is then added to the solution to form Sb 2 S 3 ol lide. The colloid was stabilized with P.V.P. Excess H 2 S was removed by bubbling with nitrogen. The preparation was then filtered through a 0.22 μm membrane filter and aliquots containing 1.017 mg Sb 2 S 3 were dispensed into the reaction vials. Labeling was accomplished by adding 99 mTcO 4 and HCl to the vial and then heating it at 100 deg C in boiling water bath for 10 min. The P H was adjust by adding a phosphate buffer. The radiochemical purity of 99 mTc-antimony disulfide colloid by I TLC-S G/normal saline was more than 95 percent. The amount of Sb in reaction vial was 0. 729 mg. The study demonstrated that our formulation of antimony-sulfide which has 0.0486 mg (Sb) in 0.2 ml of 99 mTc-Sb 2 S 3 colloid per patient (total volume after labeling with 99 mTc is 3 ml)

  16. Pelvic lymphoscintigraphy: contribution to the preoperative staging of rectal cancer

    Directory of Open Access Journals (Sweden)

    Silva José Hyppolito da

    2002-01-01

    Full Text Available PURPOSE: Preservation of the anal sphincter in surgery for cancer of the distal rectum in an attempt to avoid colostomy has been a main concern of colorectal surgeons. Various proposed procedures contradict oncological principles, especially with respect to pelvic lymphadenectomy. Therefore, prior knowledge of pelvic lymph node involvement is an important factor in choosing the operative technique, i.e., radical or conservative resection. Introduction of ultrasound, computerized tomography, and magnetic resonance have made preoperative study of the area possible. Nevertheless, these resources offer information of an anatomical nature only. Lymphoscintigraphy enables the morphological and functional evaluation of the pelvic area and contributes toward complementing the data obtained with the other imaging techniques. The objective of this prospective study is twofold: to standardize the lymphoscintigraphy technique and to use it to differentiate patients with rectal cancer from those with other coloproctologic diseases. CASUISTIC AND METHODS: Sixty patients with various coloproctologic diseases were studied prospectively. Ages ranged from 21 to 96 years (average, 51 and median, 55 years. Twenty-six patients were male and 34 were female. Thirty patients had carcinoma of the distal rectum as diagnosed by proctologic and anatomic-pathologic examinations, 20 patients had hemorrhoids, 5 had chagasic megacolon, 2 had diverticular disease, 2 had neoplasm of the right colon, and 1 had ulcerative colitis as diagnosed by proctologic exam and/or enema. The lymphoscintigraphy method consisted of injecting 0.25 mL of a dextran solution marked with radioactive technetium-99m into the right and left sides of the perianal region and obtaining images with a gamma camera. The results were analyzed statistically with a confidence level of 95% (P < .05 using the following statistical techniques: arithmetic and medium average, Fisher exact test, chi-square test

  17. Qualitative and quantitative lymphoscintigraphy in the evaluation of lower limbs lymphedema

    International Nuclear Information System (INIS)

    Dalia, Roberta Maria; Martins, Glaucia Ribeiro P.; Barbosa, Rodolfo; Lima, Carla Flavia de; Siqueira, Cristiano Ferrari

    2005-01-01

    The purpose of this study was to prove the efficiency of qualitative and quantitative lymphoscintigraphy in the diagnosis of the lower extremity lymphedema. Seventy-seven patients had been studied, most of then (85.7%) were female. Patients' ages ranged from 18 to 82 years. All patients underwent a bilateral lymphoscintigraphy. Images were recorded with a dual-detector instrument in the whole-body scanning mode. Feet and inguinal static views were acquired within 15 minutes and three hours after radiopharmaceutical injection. Two nuclear doctors evaluated the lymphoscintigrams qualitatively. Quantitative studies of the radiopharmaceutical absorption and the lymph node chain uptake were also obtained. Of the 154 evaluated members, 21.44% (n = 33) were classified as normal, 61.68% (n = 95) as mildly altered and 16.88% (n = 26) much altered. Quantitation of lymphatic chain uptake may be a more sensitive approach to the diagnosis of lymphatic impairment than the qualitative analysis. (author)

  18. Lymphoscintigraphy with 99mTc-dextran and radio guided biopsy in sentinel node localization in breast cancer

    International Nuclear Information System (INIS)

    Aguilar, C.R.; Cano, R.A.; Morales, R.E.; Mendoza, G.; Saavedra, P.; Lopez, D.; Carlos, I.; Mendoza, G.; Velarde, R.

    2002-01-01

    Aim: The aim of this work was to evaluate the usefulness of lymphoscintigraphy using Tc 99m-dextran and a gamma detection probe, previous to as well as during radio guided biopsy, in patients with breast cancer and negative findings in axilla, respectively. Materials and Methods: 33 patients (range age 27-74 years) with breast cancer diagnosis, stage I and II, with tumors smaller than 5 cm in diameter and negative findings in axilla were evaluated from June 2000 to Dec 2001 to whom 37 MBq of Tc 99m-Dextran in a volume of 0.2 cc, was infiltrated intradermically, before the patient was placed under gamma camera and the sentinel node location was marked on skin. Biopsy was done using a combined method -gamma counter and vital blue dye- in thirty-three patients. Results: The sentinel node was visualized by lymphoscintigraphy in 32 patients (32/33) between five and twelve minutes after the radiopharmaceutical was injected. Sentinel node biopsy was done in an average time of sixteen minutes, proving that the skin markers were accurate in 90 % (30/33) of cases. Three false negative patients were found. In six patients the frozen biopsy was positive and confirmed using paraffin. The identification rate using both lymphoscintigraphy and radio guided biopsy was 97%. Conclusion: Lymphoscintigraphy with Tc-99m-dextran and surgical biopsy using the combined method could identify sentinel node in 97% of the patients with breast cancer and negative findings in axilla. The rate of false negative (9.3%) was according to expected. Lymphoscintigraphy was able to define the specific lymphatic drainage in each patient (32/33) and visualize the sentinel node to predict the lymphatic flow (32/33), which is specific in each patient. Skin marks were highly accurate in helping the surgeon with less operating time

  19. Quantitative lymphoscintigraphy in post-mastectomy lymphedema: correlation with circumferential measurements

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Joon Young; Lee, Kyung Han; Kim, Sang Eun; Kim, Byung Tae; Hwang, Jee Hea; Lee, Byung Boong [Samsung Medical Center, Seoul (Korea, Republic of)

    1997-07-01

    An objective measure for the severity and progression is important for the management of lymphedema. To evaluate the usefulness of lympho-scintigraphy in this regard, we compared various quantitative indices from upper extremity lymphoscintigraphy with circumferential measurements, before and after physiotheraphy. Upper extremity lymphoscintigraphy was performed in 38 patients with unilateral postmastectomy lymphedema. Tc-99m antimony sulfide colloid (37 MBq) was injected s.c. into the second and third interdigital spaces. The injection sites were imaged immediately after injection. After standardized exercise for 15 min, upper extremity images were acquired 30 min, 1 hr and 2 hr after injection. The clearance of the injection site (CL), and % uptake in regional lymph nodes (%LN) and soft tissue of the extremity (i.e., the degree of dermal backflow) (%EXT) compared to the initial injection site were calculated. Circumference of each extremity was measured at 7 levels; the severity of lymphedema was expressed as the percentage difference of total circumferential difference (TCD) between healthy and edematous extremities compared to the total circumference of healthy extremity (%TCD). In 19 patients who received physiotherapy, the therapeutic effect was measured by % decrease of TCD (%DTCD) before and after therapy (Raines. et al., 1977). The quantitative indices calculated in the image at 2 hr p.i. had better correlation with either %TCD or %DTCD than those from earlier images (Table). The CL, %LN and %EXT of edematous extremity had a significant correlation with TCD. The %EXT was correlated best with either TCD or %DTCD. The results suggest that the %EXT which corresponds to the degree of dermal backflow may be a simple and useful quantitative index for evaluating the severity and progression in lymphedema and predicting the effect of therapy.

  20. Quantitative lymphoscintigraphy in post-mastectomy lymphedema: correlation with circumferential measurements

    International Nuclear Information System (INIS)

    Choi, Joon Young; Lee, Kyung Han; Kim, Sang Eun; Kim, Byung Tae; Hwang, Jee Hea; Lee, Byung Boong

    1997-01-01

    An objective measure for the severity and progression is important for the management of lymphedema. To evaluate the usefulness of lympho-scintigraphy in this regard, we compared various quantitative indices from upper extremity lymphoscintigraphy with circumferential measurements, before and after physiotheraphy. Upper extremity lymphoscintigraphy was performed in 38 patients with unilateral postmastectomy lymphedema. Tc-99m antimony sulfide colloid (37 MBq) was injected s.c. into the second and third interdigital spaces. The injection sites were imaged immediately after injection. After standardized exercise for 15 min, upper extremity images were acquired 30 min, 1 hr and 2 hr after injection. The clearance of the injection site (CL), and % uptake in regional lymph nodes (%LN) and soft tissue of the extremity (i.e., the degree of dermal backflow) (%EXT) compared to the initial injection site were calculated. Circumference of each extremity was measured at 7 levels; the severity of lymphedema was expressed as the percentage difference of total circumferential difference (TCD) between healthy and edematous extremities compared to the total circumference of healthy extremity (%TCD). In 19 patients who received physiotherapy, the therapeutic effect was measured by % decrease of TCD (%DTCD) before and after therapy (Raines. et al., 1977). The quantitative indices calculated in the image at 2 hr p.i. had better correlation with either %TCD or %DTCD than those from earlier images (Table). The CL, %LN and %EXT of edematous extremity had a significant correlation with TCD. The %EXT was correlated best with either TCD or %DTCD. The results suggest that the %EXT which corresponds to the degree of dermal backflow may be a simple and useful quantitative index for evaluating the severity and progression in lymphedema and predicting the effect of therapy

  1. Investigating the role of SPECT/CT in dynamic sentinel lymph node biopsy for penile cancers

    Energy Technology Data Exchange (ETDEWEB)

    Saad, Ziauddin Zia; Bomanji, Jamshed [University College Hospitals London, Department of Nuclear Medicine, London (United Kingdom); UCLH NHS Foundation Trust, Institute of Nuclear Medicine, 5th Floor, London (United Kingdom); Omorphos, Savvas; Malone, Peter; Nigam, Raj; Muneer, Asif [University College Hospitals London, Department of Urology, London (United Kingdom); Michopoulou, Sofia; Gacinovic, Svetislav [University College Hospitals London, Department of Nuclear Medicine, London (United Kingdom)

    2017-07-15

    Currently, most centres use 2-D planar lymphoscintigraphy when performing dynamic sentinel lymph node biopsy in penile cancer patients with clinically impalpable inguinal nodes. This study aimed to investigate the role of SPECT/CT following 2-D planar lymphoscintigraphy (dynamic and static) in the detection and localization of sentinel lymph nodes in the groin. A qualitative (visual) review was performed on planar followed by SPECT/CT lymphoscintigraphy in 115 consecutive patients (age 28-86 years) who underwent injection of {sup 99m}Tc-nanocolloid followed by immediate acquisition of dynamic (20 min) and early static scans (5 min) initially and further delayed static (5 min) images at 120 min followed by SPECT/CT imaging. The lymph nodes detected in each groin on planar lymphoscintigraphy and SPECT/CT were compared. A total of 440 and 467 nodes were identified on planar scintigraphy and SPECT/CT, respectively. Overall, SPECT/CT confirmed the findings of planar imaging in 28/115 cases (24%). In the remaining 87 cases (76%), gross discrepancies were observed between planar and SPECT/CT images. SPECT/CT identified 17 instances of skin contamination (16 patients, 13%) and 36 instances of in-transit lymphatic tract activity (24 patients, 20%) that had been interpreted as tracer-avid lymph nodes on planar imaging. In addition, SPECT/CT identified 53 tracer-avid nodes in 48 patients (42%) that were not visualized on planar imaging and led to reclassification of the drainage basins (pelvic/inguinal) of 27 tracer-avid nodes. The addition of SPECT/CT improved the rate of detection of true tracer-avid lymph nodes and delineated their precise (3-D) anatomic localization in drainage basins. (orig.)

  2. Evaluation of Tc-99M dextran as a useful agent for peripheral lymphoscintigraphy

    International Nuclear Information System (INIS)

    Farzana Kousar; Muhammad Numair Younis; Shabana Saeed; Mustanser Jehangir; Saeeda Asghar

    2004-01-01

    Peripheral lymphoscintigraphy is known for its great academic value and more importantly, may contribute to supporting the accuracy of clinical diagnosis and assessment of lymphedema treatment. The main aim of this study was to evaluate the 99m Tc dextran as peripheral lymphoscintigraphic agent and its validation in recognizing different lymphatic patterns in normal and edematous limbs. Methods: Peripheral lymphoscintigraphy was performed in 24 patients (mean age 43.9 ± 11 years) using 99m Tc dextran (molecular weight 150,000 and 250,000) as radiotracer. 37 MBq (1 mCi) 99m Tc dextran (PINSCANTM) was injected intradermally in the first web space of the hand or foot of both limbs. 30 minutes sequential dynamic and static imaging was done. Delayed static images were taken at one hour and then three hours post injection. Results: Only qualitative interpretation was done. Different lymphatic patterns were observed in normal population as well as in control and edematous limbs. Results were further analysed using chi square test, paired and unpaired student t test at the confidence level 0.05. All mean values were given with one standard deviation. Visual and statistical analysis showed good clinical correlation. These results were also compared favourably with 99m Tc HSA lymphoscintigraphic findings available in literature. Conclusion: 99m Tc dextran is a promising agent for peripheral lymphoscintigraphy. (authors)

  3. Lymphoscintigraphy in breast cancer: a short review about the impact on upper limb after surgical treatment

    International Nuclear Information System (INIS)

    Bergmann, Anke; Resende, Juliana Miranda Dutra de; Bello, Marcelo Adeodato; Oliveira, Juliana Flavia de; Bernardo-Filho, Mario; Santos-Filho, Sebastiao David; Palestro, Christopher J.

    2008-01-01

    Breast cancer is still associated with high mortality rates and one of the most important factors governing long survival is accurate and early diagnosis. In underdeveloped countries, this disease frequently is only detected in advanced stages; however, through mammography, many women have been diagnosed at early stages. In this context, the sentinel lymph node (SLN) technique is associated with less postoperative morbidity compared to axillary lymphadenectomy. Lymphoscintigraphy has emerged as a method for the evaluation of lymphatic drainage chains in various tumours, being both accurate and non invasive. The aim of this work is to present the main aspects which cause controversy about SLN and lymphoscintigraphy and the impact that these procedures have had on lymphedema after surgical treatment for breast cancer. A short review including papers in English, Spanish and Portuguese, available on Lilacs and Medline database, published between January, 2000 and July, 2008 was performed. The key words breast cancer, lymphoscintigraphy, SLN biopsy, lymphedema were used. Various studies have aimed to compare the incidence and prevalence of lymphedema according to the technique used; however, the population subjected to SLN is different from the one with indication for axillary lymphadenectomy regarding staging. Moreover, little is known about long term morbidity since it is a relatively new technique. In conclusion, the development of surgical techniques has permitted to minimize deformities and the current trend is that these techniques be as conservative as possible. Thus, lymphoscintigraphy plays an important role in the identification of SLN, contributing to the prevention and minimization of postoperative complications. (author)

  4. Lymphoscintigraphy in breast cancer: a short review about the impact on upper limb after surgical treatment

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, Anke; Resende, Juliana Miranda Dutra de; Bello, Marcelo Adeodato; Oliveira, Juliana Flavia de; Bernardo-Filho, Mario [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil); Santos-Filho, Sebastiao David [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Lab. de Radiofarmacia Experimental; Palestro, Christopher J. [Yeshiva University, NY (United States). Albert Einstein College of Medicine

    2008-12-15

    Breast cancer is still associated with high mortality rates and one of the most important factors governing long survival is accurate and early diagnosis. In underdeveloped countries, this disease frequently is only detected in advanced stages; however, through mammography, many women have been diagnosed at early stages. In this context, the sentinel lymph node (SLN) technique is associated with less postoperative morbidity compared to axillary lymphadenectomy. Lymphoscintigraphy has emerged as a method for the evaluation of lymphatic drainage chains in various tumours, being both accurate and non invasive. The aim of this work is to present the main aspects which cause controversy about SLN and lymphoscintigraphy and the impact that these procedures have had on lymphedema after surgical treatment for breast cancer. A short review including papers in English, Spanish and Portuguese, available on Lilacs and Medline database, published between January, 2000 and July, 2008 was performed. The key words breast cancer, lymphoscintigraphy, SLN biopsy, lymphedema were used. Various studies have aimed to compare the incidence and prevalence of lymphedema according to the technique used; however, the population subjected to SLN is different from the one with indication for axillary lymphadenectomy regarding staging. Moreover, little is known about long term morbidity since it is a relatively new technique. In conclusion, the development of surgical techniques has permitted to minimize deformities and the current trend is that these techniques be as conservative as possible. Thus, lymphoscintigraphy plays an important role in the identification of SLN, contributing to the prevention and minimization of postoperative complications. (author)

  5. 99mTc-HSA lymphoscintigraphy and leg edema after arterial reconstruction

    International Nuclear Information System (INIS)

    O-hara, Masaki; Seyama, Atsushi; Akimoto, Fumikazu; Nakamura, Takashi; Wakamatsu, Takahumi; Zempo, Nobuya; Esato, Kensuke

    1992-01-01

    To investigate the etiology of lower limb edema after arterial reconstruction, 12 patients (16 limbs) who underwent arterial reconstruction due to atherosclerosis obliterans were observed. There was no relationship between the severity of limb edema and serum factors (serum total proteins, albumin, BUN, and creatinine), ankle/brachial arterial pressure ratio, peripheral venous pressure or RI lymphoscintigraphy in the supine position. The lymphatic flow in RI lymphoscintigraphy at 3∼4 weeks after operation increased with statistically significant difference compared to the preoperative flow whether the patient was in the supine or upright position. Though there was no significant relationship between the severity of leg edema and postoperative lymphatic flow in the supine position, postoperative lymphatic flow in the upright position decreased as the severity of leg edema increased. Increased lymphatic flow in the follow-up period was associated with increased severity of leg edema in the upright position. It is concluded that postoperative leg edema is due to the damage to the lymphatic vessels during operation, and then the lymphatic channels cannot adapt to the increased lymphatic flow after the arterial reconstruction. (author)

  6. EANM practice guidelines for lymphoscintigraphy and sentinel lymph node biopsy in melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Bluemel, Christina; Herrmann, Ken; Lassmann, Michael [Universitaetsklinikum Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany); Giammarile, Francesco; Dubreuil, Julien [Universite Claude Bernard Lyon 1, Medecine Nucleaire, Hospices Civils de Lyon and EA 3738, Lyon (France); Nieweg, Omgo E.; Chakera, Annette H. [The Poche Centre, Melanoma Institute Australia, North Sydney (Australia); Testori, Alessandro [European Institute of Oncology, Milan (Italy); Audisio, Riccardo A. [University of Liverpool, St Helens Teaching Hospital, St Helens (United Kingdom); Zoras, Odysseas [University Hospital of Heraklion, Department of Surgical Oncology, Heraklion (Greece); Uren, Roger [The University of Sydney, Sydney Medical School, Sydney, NSW (Australia); Alfred Nuclear Medicine and Ultrasound, RPAH Medical Centre, Newtown, NSW (Australia); Chondrogiannis, Sotirios; Rubello, Domenico [' Santa Maria della Misericordia' Hospital, Department of Nuclear Medicine, PET/CT Centre, Radiology, NeuroRadiology, Medical Physics, Rovigo (Italy); Colletti, Patrick M. [University of Southern California, Department of Radiology, Los Angeles, CA (United States)

    2015-10-15

    Sentinel lymph node biopsy is an essential staging tool in patients with clinically localized melanoma. The harvesting of a sentinel lymph node entails a sequence of procedures with participation of specialists in nuclear medicine, radiology, surgery and pathology. The aim of this document is to provide guidelines for nuclear medicine physicians performing lymphoscintigraphy for sentinel lymph node detection in patients with melanoma. These practice guidelines were written and have been approved by the European Association of Nuclear Medicine (EANM) to promote high-quality lymphoscintigraphy. The final result has been discussed by distinguished experts from the EANM Oncology Committee, national nuclear medicine societies, the European Society of Surgical Oncology (ESSO) and the European Association for Research and Treatment of Cancer (EORTC) melanoma group. The document has been endorsed by the Society of Nuclear Medicine and Molecular Imaging (SNMMI). The present practice guidelines will help nuclear medicine practitioners play their essential role in providing high-quality lymphatic mapping for the care of melanoma patients. (orig.)

  7. A study on pulmonary hilar and mediastinal lymphoscintigraphy

    International Nuclear Information System (INIS)

    Matsuo, Michimasa; Ushio, Keiji; Nishiyama, Shoji; Kono, Michio; Takada, Yoshiki

    1979-01-01

    A routine examination of pulmonary hilar and mediastinal lymphoscintigraphy is tried in this study in order to visualize pulmonary hilar and mediastinal lymphnodes routinely. A method is as follows; 30 - 50 μCi of 198 Au-colloid (0.3 - 0.5 ml of total volume) is injected through the needle of flexible bronchofiberscope into the mucosal membrane or submucosal membrane of the bilateral B 8 or B 9 bronchi. This method was applied to 11 cases of suspected pulmonary carcinoma and gave good results. In case of bronchitis, lung abscess and chronic pneumonia, carinal lymphnodes (which are expected to be as the inferior tracheo-bronchial lymphnodes) and one or more right mediastinal lymphnodes (which are expected to be as the right superior tracheo-bronchial or right paratracheal lymphnodes) were clearly visualized from 24 to 27 hours after the injection. In these cases the pulmonary hilar and mediastinal lymphnodes were expected to be intact on x-rays and CT findings. Among cases of pulmonary carcinoma or lymphangitis carcinomatosa, on the contrary, right mediastinal lymphnodes were not visualized in case with the right hilar lymphnodes involvement, and furthermore neither carinal nor right mediastinal lymphnodes were visualized in case with carinal lymphnodes involvements on X-rays, CT, operation or autopsy findings. From these results, the pulmonary hilar and mediastinal lymphoscintigraphy may give the useful information for the treatment planning, and follow up study of the cases of pulmonary and mediastinal malignant tumors. (author)

  8. The value of parasternal lymphoscintigraphy in the treatment of operable breast cancer

    International Nuclear Information System (INIS)

    Oostveen, H.W.

    1980-01-01

    Internal mammary lymphoscintigraphy is described, a noninvasive technique, which provides data concerning anatomic variations of internal mammary lymph node distribution, involvement by metastasis of the chain and proportion of metastasis. It provides means for greater accuracy in additional radiotherapy treatment planning in patients with operable breast cancer. (Auth.)

  9. Lymphoscintigraphy and breast cancer: early and/or late image?

    International Nuclear Information System (INIS)

    Rousseau, C.; Campion, L.; Curtet, C.; Classe, J.M.; Dravet, F.; Fiche, M.; Sagan, C.; Chatal, J.F.; Resche, I.

    2001-01-01

    As the performance of early (H+1 to 4) and late (D1) lympho-scintigraphic images raises organisational problems in outpatient surgery for breast cancer, only early images are generally obtained. The present study evaluated whether two series of images are better than one and defined the advantages of both methodologies On hundred and eighteen patients with infiltrating breast carcinoma (T0, T1 and T2) were included in the study : 87 in group A (early and late images) and 31 in group B (only early images). All patients received two peritumoral injections of 99m Tc-sulphur colloid: 15-18 MBq (group A) and < 15 MBq (group B). During the operation, the patent blue technique was associated with radioactivity detection. The two groups were comparable for histological type and tumour size and localization. Successful localisation of sentinel-nodes on early lympho-scintigraphic images was significantly greater for group B. The sensitivity of early lymphoscintigraphy increased by 10% during the study. Sentinel node detection by the isotopic method alone or the two methods combined was comparable for both groups. In radioactivity detection, the count rate for sentinel nodes versus background (contralateral breast) was superposable for the two groups. During the learning phase, two series of images gave a definite advantage. Subsequently, lymphoscintigraphy performed at + 2 h was sufficient (the results for the two groups became superposable). (author)

  10. Sentinel lymphoscintigraphy in malignant melanoma and Merkel cell carcinoma

    International Nuclear Information System (INIS)

    Dekova, M.; Kirov, V.; Donchev, M.; Slavova, M.; Tsarovska, T.

    2013-01-01

    Full text:Introduction: The concept of a biopsy of the sentinel lymph node (SLN) was developed by Mortan in 1992, using blue dye. In 1993. Alex and Krag identified SLN with radiocolloid and gamma probe in case of malignant melanoma. Today, both methods are applied separately or together with a success rate above 90% and false negative rate of 5 %. Materials and Methods: The study includes 10 patients, 9 of whom have been diagnosed with malignant melanoma and 1 – with Merkel cancer. All patients were of a higher risk of lymphatic metastases without distinct clinical symptoms. Lymphoscintigraphy was performed with double-headed SPECT gamma camera Toshiba CGA 7200 UI. The visualized lymph nodes were projected and marked on the skin by a point radioactive source under monitoring. The marked lymph nodes were verified during the operation by staining and patent Blau then removed and studies histopathologically. Results: In all patients the Lymphoscintigraphy visualized SLN, which were surgically found just below the skin markers and removed. In the SLN of one patient a diffuse metastasis was found. In the SLN of nine patients no evidence for metastatic process was found. Conclusion: The technique of marking the SLN with subsequent biopsy is a minimally invasive method for the detection of lymph node metastases in patients with malignant melanoma and Merkel carcinoma with a high degree of reliability of the results

  11. Regular shock refraction in planar ideal MHD

    International Nuclear Information System (INIS)

    Delmont, P; Keppens, R

    2010-01-01

    We study the classical problem of planar shock refraction at an oblique density discontinuity, separating two gases at rest, in planar ideal (magneto)hydrodynamics. In the hydrodynamical case, 3 signals arise and the interface becomes Richtmyer-Meshkov unstable due to vorticity deposition on the shocked contact. In the magnetohydrodynamical case, on the other hand, when the normal component of the magnetic field does not vanish, 5 signals will arise. The interface then typically remains stable, since the Rankine-Hugoniot jump conditions in ideal MHD do not allow for vorticity deposition on a contact discontinuity. We present an exact Riemann solver based solution strategy to describe the initial self similar refraction phase. Using grid-adaptive MHD simulations, we show that after reflection from the top wall, the interface remains stable.

  12. Studies of lymphatic drainage from testes by lymphoscintigraphy

    International Nuclear Information System (INIS)

    Yeh, S.D.J.; Morse, M.J.; Grando, R.; Kleinert, E.L.; Whitmore, W.F. Jr.

    1985-01-01

    Severe lymphedema of lower extremity may cause functional disability and foster recurrent lymphangitis. Surgical transportation of the testis to the thigh offers the possibility of enhancing lymphatic drainage from the leg via spermatic cord lymphatics. Testicular lymphoscintigraphy was employed to assess the quality of testicular lymphatic drainage prior to testis transposition. Images of abdomen and measurement of testis radioactivity were made serially after injection of Au 198 colloid into the testis of dogs before and after litigation of the spermatic cord. In the intact dogs, the residual radioactivities in the testis (5 dogs) were 53.5 +- 13.25, 41.6 +- 7.80 and 26.3 +- 5.66% at 2, 4 and 24 hours post injection. After ligation of spermatic cord, the residual activities in the testis were 95.0 +- 3.33, 86.4 +- 6.49 and 74.2 +- 6.28% at corresponding intervals post injection. Paraaortic nodes and liver were visualized in the abdominal images 1 hour after injection in the intact animals but only poorly seen in dogs following ligation. /sup 99m/Tc antimony colloid was used similarly in 5 patients who had severe lymphedema and abnormal pelvic lymphoscintigraphy following bipedal injection. With intratesticular injection, paraaortic lymph nodes and liver were visualized in 7 studies between 3 to 5 hours. Poor visualization was noted in two studies in patients who had previous radiation to the abdomen. The findings suggest that this simple technic can aid in the assessment of testicular lymphatic drainage and help to select patients for appropriate surgical intervention

  13. Lymphoscintigraphy of the lower extremity

    International Nuclear Information System (INIS)

    Abbasi, N.Z.

    1990-01-01

    Fifty one lower extremities of 26 normal healthy volunteers and 26 extremities of 13 patients with oedema have been studied. Dynamic quantitative lymphoscintigraphy using 99Tc-m antimony sulphide colloid during passive exercise as well as before and after active exercise was performed. parameters of lymphatic function including percentage of radioactivity cleared from the injection site, the percentage uptake by the inguinal lymph nodes, the time of arrival of activity at the regional lymph nodes and the lymphatic reserve index have been evaluated. The percentage clearance of activity from the injection site was found technically difficult to standardize and proved to be an unreliable parameter of lymphatic function. However, the quantitation of nodal uptake, the lymphatic transit time and the lymphatic reserve capacity accurately depicted the lymphatic functional status of an individual. The physiologic parameters of lymphatic function of the contralateral lower extremities were compared and a physiologic difference in the lymphatic capacity of the two limbs was scintigraphically documented. (author)

  14. Comparison of subareolar injection lymphoscintigraphy with the 1-day and the 2-day protocols for the detection of sentinel lymph nodes in patients with breast cancer

    International Nuclear Information System (INIS)

    Seok, Ju-Won; Kim, In-Ju; Heo, Young-Jun; Yang, You-Jung; Choi, Yoo-Shin; Kim, Beom-Gyu; Park, Seoug-Jun

    2009-01-01

    Lymphoscintigraphy and sentinel node biopsy are used for the detection of axillary lymph node metastasis in breast cancer patients. However, currently there is no standardized technique. For the detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy, in patients with breast cancer, we compared the results of subareolar injections administered on the day of surgery (1-day protocol) with injections administered on the day before surgery (2-day protocol). This study included 412 breast cancer patients who underwent surgery between 2001 and 2004. For the 1-day protocol (1 h before surgery) 0.8 ml of Tc-99m Tin-Colloid (37 MBq) was injected in 203 in the subareolar region on the morning of the surgery. For the 2-day protocol (16 h before surgery) 0.8 ml of Tc-99m Tin-Colloid (185 MBq) was injected in 209 patients on the afternoon before surgery. Lymphoscintigraphy was performed in the supine position and sentinel node identification was performed by hand-held gamma probe during surgery. Among 203 patients with the 1-day protocol, 185 cases (91.1%) were identified by sentinel node lymphoscintigraphy, and 182 cases (89.7%) were identified by gamma probe. Among the 209 patients, in the 2-day protocol, 189 cases (90.4%) had the sentinel node identified by lymphoscintigraphy, and 182 cases (87.1%) by the gamma probe. There was no significant difference in the identification rate of the sentinel node between the 1-day and 2-day protocols by lymphoscintigraphy and the gamma probe (p>0.05, p>0.05). The results of the identification of the sentinel node by subareolar injection according to 1-day or 2-day protocol, in breast cancer patients, showed no significant differences. Because the 2-day protocol allows for an adequate amount of time to perform the lymphoscintigraphy, it is a more useful protocol for the identification of sentinel nodes in patients with breast cancer. (author)

  15. Detecting sentinel lymph nodes in caner cases of lower and middle rectum following lymphoscintigraphy

    International Nuclear Information System (INIS)

    Dontshev, M.; Dimitrov, D.; Deliysky, T.; Tsarowska, T.; Slavova, M.; Dekova, M.

    2006-01-01

    Full text: The lymphoscintigraphy and the interoperative gamma probing for through detection of the marked with radiocolloid sentinel lymph nodes (SLN) in the cases of patients having cancer in the lower and middle third of the rectum (CLMTR) are with minimum clinical experience in Bulgaria. The aim of the study is to examine the elaboration on the subject and introduction of nuclear medical methods for preoperative marking and representation of SLN and their interoperative finding thanks to gamma probing in the cases of CLMTR. This research covers 14 patients having CLMTR (3 females and 11 males) at the age of 55 - 80 (average 76,5), of whom 17 - 20 hours before the operation was carried out lymphoscintigraphy of two-headed SPECT gamma camera Toshiba CGA7200UI with 99mTc colloid applied transanal submycotic. The interoperative finding of SLN was made by the means of detection with manual gamma probe Silicone instruments. The lymphoscintigraphy visualized in 13 patients 11 SLN, and in one patient the examination was negative. The interoperative gamma sounding established the presence of activity in 12 SLN, 8 of them mezenterial and 4 of them - extramezenterial. The immunohistological examination of the biopsied 12 SLN found metastasis in two mezenterial SLN. In the rest 10 SLN there were no indications for metastatic process. The preliminary results show that the used from us nuclear medical methods are applicable for marking and finding of SLN in the cases of CLMTR aiming improvement the staging of the illness

  16. The application of the bilateral collimator to parasternal lymphoscintigraphy: a new method to measure the depth of the lymph node

    International Nuclear Information System (INIS)

    Ohtake, E.; Toyama, H.; Iio, M.; Noguchi, M.; Kawaguchi, S.; Murata, H.; Chiba, K.; Yamada, H.

    1980-01-01

    The bilateral collimator has been widely adopted for obtaining two simultaneous views of the heart in nuclear cardiology. As an additional useful clinical application of the bilateral collimator, it has been used for parasternal lymphoscintigraphy. Lymphography with a contrast medium for the parasternal lymphatics is technically very difficult and the radionuclide method is adopted. Lymphoscintigraphy has been used in order to determine the existence of malignant invasion to the lymph nodes, and also to find the depth of the lymph node as a guide to operation and radiation therapy of the nodes. (author)

  17. The role of SPECT-CT in the lymphoscintigraphic identification of sentinel nodes in patients with oral cancer

    DEFF Research Database (Denmark)

    Bilde, Anders; Von Buchwald, Christian; Mortensen, Jann

    2006-01-01

    SPECT with higher resolution CT scanners are expected to provide more accurate information about the localization of SNs. OBJECTIVE: To assess the role of combined SPECT-CT in SN identification in the clinically negative neck of patients with OSCC. MATERIALS AND METHODS: Lymphoscintigraphy comprising......CONCLUSION: SPECT-CT may improve the localization of sentinel nodes (SNs) in patients with oral squamous cell carcinoma (OSCC). Compared with planar lymphoscintigraphy SPECT-CT detected more SNs and provided additional anatomical and spatial information about their localization. New generation...... planar and SPECT-CT acquisition was performed in 34 consecutive patients with OSCC stage I and II (T1-2N0M0) prior to sentinel node biopsy (SNB) and selective neck dissection. The number of SNs and anatomical location was recorded according to lymphoscintigraphy and operative findings. RESULTS: SNB...

  18. Lymphoscintigraphy and triangulated body marking for morbidity reduction during sentinel node biopsy in breast cancer.

    Science.gov (United States)

    Krynyckyi, Borys R; Shafir, Michail K; Kim, Suk Chul; Kim, Dong Wook; Travis, Arlene; Moadel, Renee M; Kim, Chun K

    2005-11-08

    Current trends in patient care include the desire for minimizing invasiveness of procedures and interventions. This aim is reflected in the increasing utilization of sentinel lymph node biopsy, which results in a lower level of morbidity in breast cancer staging, in comparison to extensive conventional axillary dissection. Optimized lymphoscintigraphy with triangulated body marking is a clinical option that can further reduce morbidity, more than when a hand held gamma probe alone is utilized. Unfortunately it is often either overlooked or not fully understood, and thus not utilized. This results in the unnecessary loss of an opportunity to further reduce morbidity. Optimized lymphoscintigraphy and triangulated body marking provides a detailed 3 dimensional map of the number and location of the sentinel nodes, available before the first incision is made. The number, location, relevance based on time/sequence of appearance of the nodes, all can influence 1) where the incision is made, 2) how extensive the dissection is, and 3) how many nodes are removed. In addition, complex patterns can arise from injections. These include prominent lymphatic channels, pseudo-sentinel nodes, echelon and reverse echelon nodes and even contamination, which are much more difficult to access with the probe only. With the detailed information provided by optimized lymphoscintigraphy and triangulated body marking, the surgeon can approach the axilla in a more enlightened fashion, in contrast to when the less informed probe only method is used. This allows for better planning, resulting in the best cosmetic effect and less trauma to the tissues, further reducing morbidity while maintaining adequate sampling of the sentinel node(s).

  19. Fragmentation of armor piercing steel projectiles upon oblique perforation of steel plates

    Directory of Open Access Journals (Sweden)

    Aizik F.

    2012-08-01

    Full Text Available In this study, a constitutive strength and failure model for a steel core of a14.5 mm API projectile was developed. Dynamic response of a projectile steel core was described by the Johnson-Cook constitutive model combined with principal tensile stress spall model. In order to obtain the parameters required for numerical description of projectile core material behavior, a series of planar impact experiments was done. The parameters of the Johnson-Cook constitutive model were extracted by matching simulated and experimental velocity profiles of planar impact. A series of oblique ballistic experiments with x-ray monitoring was carried out to study the effect of obliquity angle and armor steel plate thickness on shattering behavior of the 14.5 mm API projectile. According to analysis of x-ray images the fragmentation level increases with both steel plate thickness and angle of inclination. The numerical modeling of the ballistic experiments was done using commercial finite element code, LS-DYNA. Dynamic response of high hardness (HH armor steel was described using a modified Johnson-Cook strength and failure model. A series of simulations with various values of maximal principal tensile stress was run in order to capture the overall fracture behavior of the projectile’s core. Reasonable agreement between simulated and x-ray failure pattern of projectile core has been observed.

  20. Development of a dextran kit for labelling with 99mTc and its evaluation for lymphoscintigraphy

    International Nuclear Information System (INIS)

    Dass, R.S.; Singh, A.K.; Chauhan, U.P.S.

    1993-01-01

    A cold dextran (molecular weight 60,000-90,000) kit has been developed by a modified procedure to produce instant preparation of 99m Tc-dextran suitable for lymphoscintigraphy. Effect of pH and amount of stannous chloride as a reducing agent on the labelling efficiency using ITLC were studied. The labelled complex was saturated from both the reduced pertechnetate and pertechnetate and quantified. In a series of experiments hydrolysed/reduced 99m Tc was found to be less than 3.0%, whereas pertechnetate was approx. 1.0%. Biokinetics of the agent in mice and blood clearance and rate of disappearance from the site of intradermal injection of the agent in rabbits were studied. The tagged agent for imaging of the lymphatic system activated by administering Freund's complete adjuvant (FCA)/E. coli in rabbits exhibited suitability for lymphoscintigraphy. (author)

  1. Behavior of obliquely incident vector Bessel beams at planar interfaces

    KAUST Repository

    Salem, Mohamed; Bagci, Hakan

    2013-01-01

    We investigate the behavior of full-vector electromagnetic Bessel beams obliquely incident at an interface between two electrically different media. We employ a Fourier transform domain representation of Bessel beams to determine their behavior upon reflection and transmission. This transform, which is geometric in nature, consists of elliptical support curves with complex weighting associated with them. The behavior of the scattered field at an interface is highly complex, owing to its full-vector nature; nevertheless, this behavior has a straightforward representation in the transform domain geometry. The analysis shows that the reflected field forms a different vector Bessel beam, but in general, the transmitted field cannot be represented as a Bessel beam. Nevertheless, using this approach, we demonstrate a method to propagate a Bessel beam in the refractive medium by launching a non- Bessel beam at the interface. Several interesting phenomena related to the behavior of Bessel beams are illustrated, such as polarized reflection at Brewster's angle incidence, and the Goos-Hänchen and Imbert-Federov shifts in the case of total reflection. © 2013 Optical Society of America.

  2. Behavior of obliquely incident vector Bessel beams at planar interfaces

    KAUST Repository

    Salem, Mohamed

    2013-01-01

    We investigate the behavior of full-vector electromagnetic Bessel beams obliquely incident at an interface between two electrically different media. We employ a Fourier transform domain representation of Bessel beams to determine their behavior upon reflection and transmission. This transform, which is geometric in nature, consists of elliptical support curves with complex weighting associated with them. The behavior of the scattered field at an interface is highly complex, owing to its full-vector nature; nevertheless, this behavior has a straightforward representation in the transform domain geometry. The analysis shows that the reflected field forms a different vector Bessel beam, but in general, the transmitted field cannot be represented as a Bessel beam. Nevertheless, using this approach, we demonstrate a method to propagate a Bessel beam in the refractive medium by launching a non- Bessel beam at the interface. Several interesting phenomena related to the behavior of Bessel beams are illustrated, such as polarized reflection at Brewster\\'s angle incidence, and the Goos-Hänchen and Imbert-Federov shifts in the case of total reflection. © 2013 Optical Society of America.

  3. The role of ultrasound and lymphoscintigraphy in the assessment of axillary lymph nodes in patients with breast cancer

    Directory of Open Access Journals (Sweden)

    Michał Nieciecki

    2016-03-01

    Full Text Available Breast cancer is the most common malignancy and the leading cause of death due to cancer in European women. Mammography screening programs aimed to increase the detection of early cancer stages were implemented in numerous European countries. Recent data show a decrease in mortality due to breast cancer in many countries, particularly among young women. At the same time, the number of sentinel node biopsy procedures and breast-conserving surgeries has increased. Intraoperative sentinel lymph node biopsy preceded by lymphoscintigraphy is used in breast cancer patients with no clinical signs of lymph node metastasis. Due to the limited sensitivity and specificity of physical examination in detecting metastatic lesions, developing an appropriate diagnostic algorithm for the preoperative assessment of axillary lymph nodes seems to be a challenge. The importance of ultrasound in patient qualification for sentinel lymph-node biopsy has been discussed in a number of works. Furthermore, different lymphoscintigraphy protocols have been compared in the literature. The usefulness of novel radiopharmaceuticals as well as the methods of image acquisition in sentinel lymph node diagnostics have also been assessed. The aim of this article is to present, basing on current guidelines, literature data as well as our own experience, the diagnostic possibilities of axillary lymph node ultrasound in patient qualification for an appropriate treatment as well as the role of lymphoscintigraphy in sentinel lymph node biopsy.

  4. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL......: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis (P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel...

  5. Lymphoscintigraphic sentinel node identification in patients with breast cancer: the role of SPECT-CT

    International Nuclear Information System (INIS)

    Lerman, H.; Metser, U.; Lievshitz, G.; Sperber, F.; Shneebaum, S.; Even-Sapir, E.

    2006-01-01

    Lymph node status is a major factor in determining the stage, appropriate therapy and outcome in patients with breast cancer. It is therefore of clinical importance to accurately identify all sentinel nodes (SNs) for each individual tumour before surgery. The purpose of this study was to assess the role of SPECT-CT lymphoscintigraphy in SN identification in patients with breast cancer. Lymphoscintigraphy comprising planar and SPECT-CT acquisition was performed in 157 consecutive patients with breast cancer (mean age 54.7±10.6, range 27-81 years) with a palpable mass (n=100), with a non-palpable mass (n=52) or post lumpectomy (n=5). Planar and SPECT-CT images were interpreted separately and the two imaging techniques were compared with respect to their ability to identify hot nodes. Planar imaging alone was negative for identification of hot nodes in 15% of the patients. SPECT-CT alone was negative in 10% and both techniques were negative in 9% of the patients. Forty-six of the total of 361 (13%) hot nodes identified by lymphoscintigraphy were detected only on SPECT-CT, including 21 nodes obscured by the scattered radiation from the injection site, nine adjacent nodes misinterpreted on planar images as a single node and 16 nodes which were missed on planar images and detected on SPECT data. SPECT-CT detected additional sites of drainage unexpected on planar images, including axillary (n=23 patients), internal mammary (n=5 patients), interpectoral (n=3 patients) and intramammary (n=2 patients) lymph node sites. Fourteen of the 329 (4%) hot lesions seen on planar images were false positive non-nodal sites of uptake that were accurately assessed by SPECT-CT and further validated by surgery. In a single patient, SPECT-CT was negative while planar images identified the SN. (orig.)

  6. Lymphoscintigraphy with intraoperative gamma probe sentinel node detection: clinical impact in patients with head and neck melanomas

    International Nuclear Information System (INIS)

    Maccauro, M.; Villano, C.; Aliberti, G.; Ferrani, L.; Castellani, M.R.; Bombardieri, E.; Patuzzo, R.; Santinami, M.; Tshering, D.

    2005-01-01

    Aim. The aims of this paper were to evaluate the clinical relevance of lymphoscintigraphy with intraoperative gamma-probe detection in identifying sentinel nodes (SNs) and to study the prognostic value of SN biopsy in head and neck melanoma patients. Methods. Sixty-one patients had lymphoscintigraphy with intradermal injections of 99m Tc-Nanocoll (40 MBq), 24 h before surgery. Tumor-positive SNs patients underwent total lymph node dissection Postoperative histological examination was performed. Patients were followed up for 1 to 5 years (median 3 years). The tumor relapses and the overall survival were evaluated by means of statistical methods. Results. Lymphoscintigraphy showed lymphatic distribution to more than one basin in 45 patients (74%), in 15 patients one basin was visualized and no basin in 1 patient. In 41 patients the SN was negative for metastases, while in 20 was positive. In a high percentage of patients (30%), metastatic involvement occurred in more than one lymph node basin. During follow-up in the negative SN group, 40 patients remained disease free and 1 relapsed. In the positive SN group, 10 patients remained disease free and 10 relapsed. Recurrence time ranged from 6 to 11 months. The overall survival of the SNs negative group was significantly higher than the positive SN group. Conclusion. This approach was able to distinguish: a) patients with tumor-negative SNs with a favorable clinical course (98% did not relapse, P<0.001); b) patients with tumor-positive SNs with a high rate of tumor relapse (50%, P<0.001). Therefore SN biopsy may give information about prognosis in head and neck melanoma patients

  7. Pelvic lymphoscintigraphy: contribution to the preoperative staging of rectal cancer; Linfocintilografia pelvica. Contribuicao ao estadiamento pre-operatorio do cancer retal

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jose Hyppolito da

    1996-12-31

    Preservation of the lower rectal sphincters has been the main concern of colorectal surgeons in an attempt to avoid colostomy. Various proposed procedures contradict the oncological principles of the operation`s radicality, especially pelvic lymphadenectomy. Prior knowledge of this space is therefore, an important factor in choosing the operative technique: radical (amputation), or conservative. The introduction of ultrasound, computed tomography and magnetic resonance imaging, have provided preoperative information about the anatomic nature of the region. The morphological and functional study supplied by lymphoscintigraphy of this space supplements the data furnished by the other imaging techniques. The objective of this prospective of this prospective study was threefold: to standardize lymphoscintigraphy, to differentiate patients with rectal cancer from those with other coloproctological diseases and to asses the lymphonodal involvement in the former by utilizing the anatomopathological and surgical correlation. The study included 60 patients with various coloproctological diseases seen on the Department of Gastroentorology, Hospital da Clinicas, University of Sao Paulo School of Medicine, from September 1990 to August 1993. Thirty were cases of rectal cancer and the remainder were other colorectal diseases. The method consisted of injecting 0.5 of a dextran solution market with radioactive technetium in the perineal region and obtaining images by a gamma camera. In the rectal cancer patients, the tracer progresses unilaterally or is absent; in the others, it is bilateral and symmetrical, although its progress may be slow. The statistical data demonstrated that in rectal cancer, lymphoscintigraphy asseses the nodal involvement approximaltely as that obtained by the sun of the anatomapathological and surgical findings. Based on the results, the following conclusioons were possible: lymphoscintigraphy is a standardized, painless and harmless test that can be

  8. Pelvic lymphoscintigraphy: contribution to the preoperative staging of rectal cancer; Linfocintilografia pelvica. Contribuicao ao estadiamento pre-operatorio do cancer retal

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jose Hyppolito da

    1997-12-31

    Preservation of the lower rectal sphincters has been the main concern of colorectal surgeons in an attempt to avoid colostomy. Various proposed procedures contradict the oncological principles of the operation`s radicality, especially pelvic lymphadenectomy. Prior knowledge of this space is therefore, an important factor in choosing the operative technique: radical (amputation), or conservative. The introduction of ultrasound, computed tomography and magnetic resonance imaging, have provided preoperative information about the anatomic nature of the region. The morphological and functional study supplied by lymphoscintigraphy of this space supplements the data furnished by the other imaging techniques. The objective of this prospective of this prospective study was threefold: to standardize lymphoscintigraphy, to differentiate patients with rectal cancer from those with other coloproctological diseases and to asses the lymphonodal involvement in the former by utilizing the anatomopathological and surgical correlation. The study included 60 patients with various coloproctological diseases seen on the Department of Gastroentorology, Hospital da Clinicas, University of Sao Paulo School of Medicine, from September 1990 to August 1993. Thirty were cases of rectal cancer and the remainder were other colorectal diseases. The method consisted of injecting 0.5 of a dextran solution market with radioactive technetium in the perineal region and obtaining images by a gamma camera. In the rectal cancer patients, the tracer progresses unilaterally or is absent; in the others, it is bilateral and symmetrical, although its progress may be slow. The statistical data demonstrated that in rectal cancer, lymphoscintigraphy asseses the nodal involvement approximaltely as that obtained by the sun of the anatomapathological and surgical findings. Based on the results, the following conclusioons were possible: lymphoscintigraphy is a standardized, painless and harmless test that can be

  9. Benefits of sagittal-oblique MRI reconstruction of anterior cruciate ligament of the knee

    International Nuclear Information System (INIS)

    Nenezić, D.

    2015-01-01

    Full text: MRI examination of the anterior cruciate ligament (ACL) of the knee gives valuable information for conventional, physiatrist and/or arthroscopic microinvasiv treatment. three planar MRI examination and 3D reconstructions are highly precise in the analysis of the intra and periarticular structures, with exceptions of anterior cruciate ligament. Direct contact with the roof of the intercondilar fossa (in the full extension during the examination) and its specific orientation makes visualization of ACL diagnostically problematic. In a one year period precise protocol for MRI visualization of ACL was tested and applied as “Sagittal Oblique MRI Reconstruction”. In short, it has been Angled biplanar reconstruction in the parasagital and paratransversal planes (patientrelated and arbitrary selected in full extension), on T2, 2mm slice and 0,2 mm gap. 153 MRI examinations of the patients with lesions of the ACL were included in the study in the Clinical Center of Montenegro during 2005 year. Beside standard Knee MRI protocol all patients had the Sagittal Oblique MRI reconstruction of ACL and the Flexion MRI examination, to compare with. The Sagittal Oblique MRI reconstruction of ACL it is adapted to the concrete morphology of the patients ACL and it does not depend of the volume of the examined knee. In comparison with the Standard Knee MRI protocol and with the Flexion MRI examination, the Sagittal Oblique MRI reconstruction of ACL takes less time to perform, and the ligament is shown in fool length at three to five slices, which is more than with the both compared protocols. Sagittal Oblique MRI Reconstruction of ACL is therefore patient dependable, orientated in shape of concrete ligament of the patient’s knee. In combination with age, occupation, physical activity and level of patients while to contribute in healing process, the Sagittal Oblique MRI reconstruction of ACL contribute to scholastic approach, as highest benefit to patients with

  10. SEMANTIC BUILDING FAÇADE SEGMENTATION FROM AIRBORNE OBLIQUE IMAGES

    Directory of Open Access Journals (Sweden)

    Y. Lin

    2018-05-01

    Full Text Available With the introduction of airborne oblique camera systems and the improvement of photogrammetric techniques, high-resolution 2D and 3D data can be acquired in urban areas. This high-resolution data allows us to perform detailed investigations on building roofs and façades which can contribute to LoD3 city modeling. Normally, façade segmentation is achieved from terrestrial views. In this paper, we address the problem from aerial views by using high resolution oblique aerial images as the data source in urban areas. In addition to traditional image features, such as RGB and SIFT, normal vector and planarity are also extracted from dense matching point clouds. Then, these 3D geometrical features are projected back to 2D space to assist façade interpretation. Random forest is trained and applied to label façade pixels. Fully connected conditional random field (CRF, capturing long-range spatial interactions, is used as a post-processing to refine our classification results. Its pairwise potential is defined by a linear combination of Gaussian kernels and the CRF model is efficiently solved by mean field approximation. Experiments show that 3D features can significantly improve classification results. Also, fully connected CRF performs well in correcting noisy pixels.

  11. Semantic Building FAÇADE Segmentation from Airborne Oblique Images

    Science.gov (United States)

    Lin, Y.; Nex, F.; Yang, M. Y.

    2018-05-01

    With the introduction of airborne oblique camera systems and the improvement of photogrammetric techniques, high-resolution 2D and 3D data can be acquired in urban areas. This high-resolution data allows us to perform detailed investigations on building roofs and façades which can contribute to LoD3 city modeling. Normally, façade segmentation is achieved from terrestrial views. In this paper, we address the problem from aerial views by using high resolution oblique aerial images as the data source in urban areas. In addition to traditional image features, such as RGB and SIFT, normal vector and planarity are also extracted from dense matching point clouds. Then, these 3D geometrical features are projected back to 2D space to assist façade interpretation. Random forest is trained and applied to label façade pixels. Fully connected conditional random field (CRF), capturing long-range spatial interactions, is used as a post-processing to refine our classification results. Its pairwise potential is defined by a linear combination of Gaussian kernels and the CRF model is efficiently solved by mean field approximation. Experiments show that 3D features can significantly improve classification results. Also, fully connected CRF performs well in correcting noisy pixels.

  12. Inferior oblique weakening surgery on ocular torsion in congenital superior oblique palsy

    Directory of Open Access Journals (Sweden)

    Jinho Lee

    2015-06-01

    Full Text Available AIM:To investigate changes in fundus excyclotorsion after inferior oblique myectomy or myotomy.METHODS:The records of 21 patients undergoing strabismus surgery by a single surgeon between 2009 and 2012 were examined. Only patients who had undergone an inferior oblique myectomy or myotomy, with or without horizontal rectus muscle surgery, were evaluated. Digital fundus photographs were obtained, and the angle formed by a horizontal line passing through the optic disc center and a reference line connecting the foveola and optic disc center was measured. Associated clinical factors examined include age at the time of surgery, presence or absence of a head tilt, degree of preoperative vertical deviation, torsional angle, inferior oblique muscle overaction/superior oblique muscle underaction, and surgery laterality. Whether the procedure was performed alone or in combination with a horizontal rectus muscle surgery was also examined.RESULTS:Mean preoperative torsional angle was 12.0±6.4°, which decreased to 6.9±5.7° after surgery (P<0.001, paired t-test. Torsional angle also decreased from 15.1±7.0° to 6.2±4.3° in the myectomy group (P<0.001, paired t-test but there were no significant changes in the myotomy group (P=0.093, Wilcoxon signed rank test. Multivariable linear regression analysis showed that preoperative torsional angle, degree of inferior oblique overaction, and age at surgery independently and significantly affected postoperative torsional angle.CONCLUSION:Mean torsional angle decreased after inferior oblique myectomy. Degree of preoperative torsional angle, inferior oblique overaction, and age at surgery influence postoperative torsional angle.

  13. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    International Nuclear Information System (INIS)

    Tuite, M.J.; Asinger, D.; Orwin, J.F.

    2001-01-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  14. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J; Asinger, D; Orwin, J F [Dept. of Radiology, Univ. of Wisconsin Hospital and Clinics, Madison, WI (United States)

    2001-05-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  15. Lymphoscintigraphy and identification of lymph nodes in patients with cervix carcinoma undergoing radical hysterectomy

    International Nuclear Information System (INIS)

    Alonso, Omar; Lago, Graciela; Juri, Cecilia; Touya, Eduardo; Arribeltz, Gualberto; Dabezies, Luis; Alvarez, Carmen; Sotero, Gonzalo; Martinez, Jorge

    2003-01-01

    One of the most important prognostic features of early cervix cancer is the involvement of regional lymph nodes (LN). Although not fully studied, the sentinel node (SN) strategy has the potential of preventing unnecessary extensive LN dissections in these patients. The aim of this study was to determine the feasibility of SN identification by means of preoperative lymphoscintigraphy (PL) and intraoperative gamma probe detection (IGPD) in patients undergoing radical hysterectomy and pelvic/para-aortic lymphadenectomy for the treatment of early cervix carcinoma. (author)

  16. Surface electromyography activity of the rectus abdominis, internal oblique, and external oblique muscles during forced expiration in healthy adults.

    Science.gov (United States)

    Ito, Kenichi; Nonaka, Koji; Ogaya, Shinya; Ogi, Atsushi; Matsunaka, Chiaki; Horie, Jun

    2016-06-01

    We aimed to characterize rectus abdominis, internal oblique, and external oblique muscle activity in healthy adults under expiratory resistance using surface electromyography. We randomly assigned 42 healthy adult subjects to 3 groups: 30%, 20%, and 10% maximal expiratory intraoral pressure (PEmax). After measuring 100% PEmax and muscle activity during 100% PEmax, the activity and maximum voluntary contraction of each muscle during the assigned experimental condition were measured. At 100% PEmax, the external oblique (pinternal oblique (pexternal oblique (pinternal oblique (pexternal oblique: pinternal oblique: p<0.01). The abdominal oblique muscles are the most active during forced expiration. Moreover, 30% PEmax is the minimum intensity required to achieve significant, albeit very slight, muscle activity during expiratory resistance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Application of three-dimensional CT reconstruction technology on inferior oblique muscle in congenital superior oblique palsy

    Directory of Open Access Journals (Sweden)

    Yang Zhang

    2014-05-01

    Full Text Available AIM: To investigate the viability of the morphology of inferior oblique muscle observed stereoscopically using 3-dimensional CT reconstruction technique. METHODS: This control study included of 29 cases which were clinically diagnosed with monocular congenital superior oblique palsy, examined by dimensional CT. The images of the inferior oblique muscle were reconstructed by Mimics software. 3D digital images on the basis of CT scanning data of the individuals were established. Observing the morphology of binocular inferior oblique muscle by self-controlled design, we compared the maximum transverse diameter of inferior oblique muscle of paralyzed eye with non-paralyzed one. We chose 5% as the significant level.RESULTS: The reconstructed results of 3-dimensional CT scan showed that not all of the inferior oblique abdominal muscle of paralyzed eyes were thinner than that of the non-paralyzed eye in maximum transverse diameter of cross-sectional area. The maximum transverse diameter of inferior oblique muscle was measured. The average maximum transverse diameter of the paralyzed eye was 6.797±1.083mm and the non-paralyzed eye was 6.507±0.848mm. The maximum transverse diameter of inferior oblique muscle of paralyzed eye did not, however, differ significantly from the normal(P>0.05. CONCLUSION: The three-dimensional CT reconstruction technology can be used for preoperative evaluation of the morphology of inferior oblique muscle.

  18. Sentinel node localisation using pre-operative lymphoscintigraphy and intraoperative gamma probe in early oral cavity cancer

    International Nuclear Information System (INIS)

    Ikram, M.; Akhtar, S.; Junaid, M.; Dhari, T.; Zaman, M.U.; Hussain, R.

    2013-01-01

    Objectives: To assess the diagnostic value of sentinel lymph node localisation using pre-operative lymphoscintigraphy and intra-operative gamma probe radio localisation in Pakistani patients suffering from early stage squamous cell carcinoma of the oral cavity. Methods: The prospective case series was conducted between September 2007 and April 2010 at the Aga Khan University Hospital, Karachi. It comprised patients with T1 and T2 oral cavity cancer with clinically and radiologically negative neck. Pre-operative lymphoscintigraphy was performed one day before surgery and intra-operative gamma probe was used to detect sentinel node. Final histo-pathological evaluation was taken as the gold standard. Results: The study comprised 42 patients: 32(76%) males and 10(24%) females. The primary tumour site was buccal mucosa in 25 (60%) patients, and tongue in 17 (40%). Sentinel lymph node was detected in 38 (90%) patients. On final histopathological identification, 7 (17%) patients had cancer in the neck nodes. In all patients with metastasis, sentinel lymph node technique correctly identified the involved neck level. None of the patients revealed metastasis in non-sentinel lymph nodes. Conclusion:Evidence suggested the use of sentinel node biopsy in patients with head and neck squamous cell carcinoma. (author)

  19. Planarity constrained multi-view depth map reconstruction for urban scenes

    Science.gov (United States)

    Hou, Yaolin; Peng, Jianwei; Hu, Zhihua; Tao, Pengjie; Shan, Jie

    2018-05-01

    Multi-view depth map reconstruction is regarded as a suitable approach for 3D generation of large-scale scenes due to its flexibility and scalability. However, there are challenges when this technique is applied to urban scenes where apparent man-made regular shapes may present. To address this need, this paper proposes a planarity constrained multi-view depth (PMVD) map reconstruction method. Starting with image segmentation and feature matching for each input image, the main procedure is iterative optimization under the constraints of planar geometry and smoothness. A set of candidate local planes are first generated by an extended PatchMatch method. The image matching costs are then computed and aggregated by an adaptive-manifold filter (AMF), whereby the smoothness constraint is applied to adjacent pixels through belief propagation. Finally, multiple criteria are used to eliminate image matching outliers. (Vertical) aerial images, oblique (aerial) images and ground images are used for qualitative and quantitative evaluations. The experiments demonstrated that the PMVD outperforms the popular multi-view depth map reconstruction with an accuracy two times better for the aerial datasets and achieves an outcome comparable to the state-of-the-art for ground images. As expected, PMVD is able to preserve the planarity for piecewise flat structures in urban scenes and restore the edges in depth discontinuous areas.

  20. Comparative study of unilateral versus bilateral inferior oblique recession/anteriorization in unilateral inferior oblique overaction.

    Science.gov (United States)

    Mostafa, Attiat M; Kassem, Rehab R

    2018-05-01

    To compare the effect of, and the rate of subsequent development of iatrogenic antielevation syndrome after, unilateral versus bilateral inferior oblique graded recession-anteriorization to treat unilateral inferior oblique overaction. Thirty-four patients with unilateral inferior oblique overaction were included in a randomized prospective study. Patients were equally divided into 2 groups. Group UNI underwent unilateral, group BI bilateral, inferior oblique graded recession-anteriorization. A successful outcome was defined as orthotropia, or within 2 ∆ of a residual hypertropia, in the absence of signs of antielevation syndrome, residual inferior oblique overaction, V-pattern, dissociated vertical deviation, or ocular torticollis. A successful outcome was achieved in 11 (64.7%) and 13 (76.5%) patients in groups UNI and BI, respectively (p = 0.452). Antielevation syndrome was diagnosed as the cause of surgical failure in 6 (35.3%) and 2 (11.8%) patients, in groups UNI and BI, respectively (p = 0.106). The cause of surgical failure in the other 2 patients in group BI was due to persistence of ocular torticollis and hypertropia in a patient with superior oblique palsy and a residual V-pattern and hypertropia in the other patient. The differences between unilateral and bilateral inferior oblique graded recession-anteriorization are insignificant. Unilateral surgery has a higher tendency for the subsequent development of antielevation syndrome. Bilateral surgery may still become complicated by antielevation syndrome, although at a lower rate. In addition, bilateral surgery had a higher rate of undercorrection. Further studies on a larger sample are encouraged.

  1. Double elevator weakening for unilateral congenital superior oblique palsy with ipsilateral superior rectus contracture and lax superior oblique tendon.

    Science.gov (United States)

    Khan, Arif O

    2012-06-01

    In unilateral congenital superior oblique palsy, a large hypertropia is sometimes associated with ipsilateral contracture of the superior rectus muscle and apparent overaction of the contralateral superior oblique. Ipsilateral double elevator weakening is one surgical approach; however, this procedure could compromise supraduction. We report a series of three consecutive patients who underwent ipsilateral superior rectus and inferior oblique recessions for unilateral superior oblique palsy. Intraoperatively, all three patients were found to have a lax ipsilateral superior oblique tendon. Postoperatively, all three patients had satisfactory correction of the hypertropia and abnormal head position with minimal supraduction defect. This procedure seems to be an acceptable initial surgical option for treating congenital superior oblique muscle palsy with ipsilateral contracture of the superior rectus muscle, even when the ipsilateral superior oblique tendon is lax. Copyright © 2012 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  2. Radio-guided sentinel lymph node identification by lymphoscintigraphy fused with an anatomical vector profile: clinical applications.

    Science.gov (United States)

    Niccoli Asabella, A; Antonica, F; Renna, M A; Rubini, D; Notaristefano, A; Nicoletti, A; Rubini, G

    2013-12-01

    To develop a method to fuse lymphoscintigraphic images with an adaptable anatomical vector profile and to evaluate its role in the clinical practice. We used Adobe Illustrator CS6 to create different vector profiles, we fused those profiles, using Adobe Photoshop CS6, with lymphoscintigraphic images of the patient. We processed 197 lymphoscintigraphies performed in patients with cutaneous melanomas, breast cancer or delayed lymph drainage. Our models can be adapted to every patient attitude or position and contain different levels of anatomical details ranging from external body profiles to the internal anatomical structures like bones, muscles, vessels, and lymph nodes. If needed, more new anatomical details can be added and embedded in the profile without redrawing them, saving a lot of time. Details can also be easily hidden, allowing the physician to view only relevant information and structures. Fusion times are about 85 s. The diagnostic confidence of the observers increased significantly. The validation process showed a slight shift (mean 4.9 mm). We have created a new, practical, inexpensive digital technique based on commercial software for fusing lymphoscintigraphic images with built-in anatomical reference profiles. It is easily reproducible and does not alter the original scintigraphic image. Our method allows a more meaningful interpretation of lymphoscintigraphies, an easier recognition of the anatomical site and better lymph node dissection planning.

  3. Lymph Drainage Studied by Lymphoscintigraphy in the Arms after Sentinel Node Biopsy Compared with Axillary Lymph Node Dissection Following Conservative Breast Cancer Surgery

    International Nuclear Information System (INIS)

    Celebioglu, F.; Perbeck, L.; Frisell, J.; Groendal, E.; Svensson, L.; Danielsson, R.

    2007-01-01

    Purpose: To investigate lymphatic drainage as measured by lymphoscintigraphy in the arms of patients undergoing either sentinel lymph node biopsy (SNB) or axillary lymph node dissection (ALND). Material and Methods: From January 2001 to December 2002, 30 patients with unilateral invasive breast carcinoma underwent breast-conserving surgery with SNB and 30 patients with ALND. All patients received radiotherapy to the breast. Lymphoscintigraphy was performed, and skin circulation, skin temperature, and arm volume were measured 2-3 years after radiotherapy. Results: None of the 30 patients who underwent SNB showed any clinical manifestation of lymphedema. Of the 30 patients undergoing ALND, six (20%) had clinical lymphedema, with an arm volume that was >10% larger on the operated than on the non-operated side (P<0.01). Scintigraphically, visual analysis revealed lymphatic dysfunction in three patients, manifested as forearm dermal back flow. Two of these patients also had an increased arm volume. Quantitative analysis showed no differences between the groups, apart from a smaller amount of isotope in the axilla in the ALND group. There was no difference in skin circulation or skin temperature. Conclusion: Our study shows that lymph drainage in the operated arm compared with the non-operated arm was less affected by SNB than by ALND, and that morbidity associated with SNB was lower than with ALND. However, the results do not confirm our hypothesis that lymphoscintigraphy can reveal differences in lymph circulation that are not evident clinically in the form of manifest lymphedema. The most sensitive clinical method of assessing lymph drainage seems to be measurement of arm volume

  4. Peritumoural vs intratumoural injections in sentinel node lymphoscintigraphy

    International Nuclear Information System (INIS)

    MacFarlane, L.; Cardaci, G.

    2002-01-01

    Full text: Lymphoscintigraphy has emerged as a method of detecting sentinel lymph nodes (SLN) in breast cancer. Our department started performing these studies in 2001, using 99mTc-Colloidal Antimony Sulphide Injection -dose 30-50MBq. Two methods of injection were used: (a) peritumoural plus subdermal injection - 1.25ml volume (PT), or (b) direct intratumoural injection - 0.2ml volume (IT), both followed by 5-10 min of gentle massage. Patients with a non-palpable mass required a hookwire (HW) inserted at time of injection, and a hotpack was applied in lieu of massage. 125 patients were retrospectively assessed, with 45 PT, 37 IT, 38 HW, and 5 patients had cavity injections. For PT injections, 93% had axillary node drainage (AN), 27% had internal mammary node drainage (IM) and 4% had no drainage to nodes, despite delayed imaging. For IT injections, 84% had AN, 24% had IM, 11% showed no drainage. Of patients having HW, 66% had AN, 34% had IM, 26% no drainage. In our experience, PT injection has a higher yield for SLN localisation than direct IT injection. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. Preliminary studies of monoclonal antibody lymphoscintigraphy in malignant melanoma

    International Nuclear Information System (INIS)

    Nelp, W.B.; Eary, J.F.; Jones, R.F.; Hellstrom, K.E.; Hellstrom, I.; Beaumier, P.L.; Krohn, K.A.

    1987-01-01

    Lymphoscintigraphy was performed at 3 and 20 hr following subcutaneous injection of 131 I anti-melanoma antibody (Fab) in 11 patients who had surgical resection of lymph nodes (neck, axilla, groin) at 24 hr for suspected metastatic melanoma. Comparable amounts of 125 I nonspecific control antibody (Fab) were co-administered. Six patients had nodal metastases and three showed positive images at both time periods. Five patients had no metastases though one was image positive. Four other nondiseased inguinal node groups were image negative. A total of 28 tumored nodes and 110 normal nodes were removed, counted and histologically examined. All metastatic tumors expressed antigen against which the specific Fab was directed. The concentrations of both specific and nonspecific Fab were similar in tumored nodes and both were significantly greater than in normal nodes showed essentially identical intranodal spatial distribution of the specific and control Fab in areas containing tumor. These preliminary results suggest the increased concentration of murine immunoglobulin (Fab) retained in diseased nodes was a nonspecific phenomenon

  6. Superior oblique luxation and trochlear luxation as new concepts in superior oblique muscle weakening surgery

    NARCIS (Netherlands)

    Mombaerts, I.; Koornneef, L.; Everhard-Halm, Y. S.; Hughes, D. S.; Maillette de Buy Wenniger-Prick, L. J.

    1995-01-01

    We used superior oblique luxation and trochlear luxation as new surgical procedures to treat acquired Brown's syndrome and superior oblique muscle overaction. We studied nine patients (11 eyes) who underwent trochlear surgery between 1988 and 1993. Four patients had acquired Brown's syndrome and

  7. WKB solution 4×4 for electromagnetic waves in a planar magnetically anisotropic inhomogeneous layer

    Science.gov (United States)

    Moiseeva, Natalya Michailovna; Moiseev, Anton Vladimirovich

    2018-04-01

    In the paper, an oblique incidence of a plane electromagnetic wave on a planar magnetically anisotropic inhomogeneous layer is considered. We consider the case when all the components of the magnetic permeability tensor are non zero and vary with distance from the interface of media. The WKB method gives a matrix 4 × 4 solution for the projections of the electromagnetic wave fields during its propagation. The dependence of the cross-polarized components on the orientation of the anisotropic medium relative to the plane of incidence of the medium is analyzed.

  8. Quantitative Lymphoscintigraphy to Predict the Possibility of Lymphedema Development After Breast Cancer Surgery: Retrospective Clinical Study.

    Science.gov (United States)

    Kim, Paul; Lee, Ju Kang; Lim, Oh Kyung; Park, Heung Kyu; Park, Ki Deok

    2017-12-01

    To predict the probability of lymphedema development in breast cancer patients in the early post-operation stage, we investigated the ability of quantitative lymphoscintigraphic assessment. This retrospective study included 201 patients without lymphedema after unilateral breast cancer surgery. Lymphoscintigraphy was performed between 4 and 8 weeks after surgery to evaluate the lymphatic system in the early postoperative stage. Quantitative lymphoscintigraphy was performed using four methods: ratio of radiopharmaceutical clearance rate of the affected to normal hand; ratio of radioactivity of the affected to normal hand; ratio of radiopharmaceutical uptake rate of the affected to normal axilla (RUA); and ratio of radioactivity of the affected to normal axilla (RRA). During a 1-year follow-up, patients with a circumferential interlimb difference of 2 cm at any measurement location and a 200-mL interlimb volume difference were diagnosed with lymphedema. We investigated the difference in quantitative lymphoscintigraphic assessment between the non-lymphedema and lymphedema groups. Quantitative lymphoscintigraphic assessment revealed that the RUA and RRA were significantly lower in the lymphedema group than in the non-lymphedema group. After adjusting the model for all significant variables (body mass index, N-stage, T-stage, type of surgery, and type of lymph node surgery), RRA was associated with lymphedema (odds ratio=0.14; 95% confidence interval, 0.04-0.46; p=0.001). In patients in the early postoperative stage after unilateral breast cancer surgery, quantitative lymphoscintigraphic assessment can be used to predict the probability of developing lymphedema.

  9. Lymphoscintigraphy and SPECT/CT in multicentric and multifocal breast cancer: does each tumour have a separate drainage pattern? Results of a Dutch multicentre study (MULTISENT)

    NARCIS (Netherlands)

    Brouwer, O. R.; Vermeeren, L.; van der Ploeg, I. M. C.; Valdés Olmos, R. A.; Loo, C. E.; Pereira-Bouda, L. M.; Smit, F.; Neijenhuis, P.; Vrouenraets, B. C.; Sivro-Prndelj, F.; Jap-A-Joe, S. M.; Borgstein, P. J.; Rutgers, E. J. Th; Oldenburg, H. S. A.

    2012-01-01

    To investigate whether lymphoscintigraphy and SPECT/CT after intralesional injection of radiopharmaceutical into each tumour separately in patients with multiple malignancies in one breast yields additional sentinel nodes compared to intralesional injection of the largest tumour only. Patients were

  10. Comparison of subdermal and peritumoral injection techniques of lymphoscintigraphy to determine the sentinel lymph node in breast cancer

    International Nuclear Information System (INIS)

    Mudun, A.; Eroglu, A.; Berberoglu, K.; Cantez, S.; Asoglu, O.; Ozmen, V.; Muslumanoglu, M.; Bozfakioglu, Y.

    2002-01-01

    Aim: The aim of this study was to evaluate the value of two different injection techniques for lymphoscintigraphy (LS) to determine the axillary sentinel lymph node (SLN) in patients (pts) with breast cancer. Patients and Methods: Thirty-six pts with early breast cancer were prospectively studied. For LS with peritumoral (PT) injection, Tc 99m-rhenium sulfide colloid (20 Mbq/ml total) was injected into four quadrants around the tumor and 2-hour delayed static images of anterior and lateral chest of pts were obtained with a dual-head gamma camera. For subdermal (SD) lymphoscintigraphy the same dose in one injector was injected subdermally into the skin over the tumor. Dynamic images for 45 minutes and later 5-minutes static images of anterior and lateral chest were obtained. On the operation intraoperatif gamma probe was used to find the axillary SLN(s) and followed by primary tumor excision and level 1-2 axillary dissection. SLN(s) and whole axillary specimens were evaluated by histopathologically. Results: With both injection techniques, 16/36 pts had completely identical drainage sites and equal no. of the SLNs. Nineteen of 36 pts showed identical lymphatic drainage sites with different no. of SLNs. With PT injection 9/36 pts, with SD injections 2/36 pts (%92) did not show any drainage and SLN. Intrasurgical gamma probe revealed axillary SLN(s) in 35/36 pts (success rate % 97). With both injection techniques there was no significant difference between the success rate of SLN detection and ages of pts, size and site of the tumor and history of previous excisional biopsy. Internal mammary lymphatics (IM) drainage visualization rate were 8/36 with PT injections and 3/36 with SD injections. Other LNs visualization rate were 7/36 with PT injections and 8/36 with SD injections. Conclusion: These findings showed that the success rate of SD injection technique is higher than PT injection technique in visualizing the axillary SLN. To increase the visualization of axillary

  11. The oblique cord of the forearm in man.

    Science.gov (United States)

    Tubbs, R Shane; O'Neil, James T; Key, Christopher D; Zarzour, Jessica G; Fulghum, Sarah B; Kim, Eugenia J; Lyerly, Michael J; Shoja, Mohammadali M; George Salter, E; Jerry Oakes, W

    2007-05-01

    There is minimal and often conflicting data in the literature regarding the oblique cord of the forearm. The current study seeks to elucidate further the anatomy of this structure of the upper extremity. In adult cadavers, the oblique cord was observed for and, when found, measurements were made of it. Ranges of motion were carried out while observation of the oblique cord was made. An oblique cord was found on 52.6% of sides. Gantzer's muscle was found on 55% of sides and, when present, had attachment into the oblique cord on five sides. The oblique cord was present on 13 sides with a Gantzer's muscle. Of the 20 sides with an oblique cord, no Gantzer's muscle was found on 10. The mean length of the oblique cord was 3.4 cm. In the majority of specimens, this cord tapered from proximal to distal. The proximal, middle, and distal widths of this structure had means 9, 7, and 4 mm, respectively. The oblique cord was found to travel approximately 45 degrees from a line drawn through the ulna and more or less traveled perpendicular to the insertion site of the bicipital tendon. This ligament was lax in the neutral position and with pronation became lax in all specimens. The oblique cord progressively became taut with increased supination from the neutral position and was maximally taut with the forearm fully supinated. Tautness of this cord was also found with distal distraction of the radius. Following the transection of the oblique cord, no discernable difference was observed in regard to maximal supination of the forearm or distal distraction of the radius. No obvious instability of the proximal forearm was found following transection of the oblique cord. Functionally, although the oblique cord may resist supination, it is unlikely that this structure affords significant stability to the proximal forearm, as it was often absent, of a very small caliber, and based on our observations, following its transection, the amount of supination of the forearm did not increase

  12. Advantages of preoperative ultrasound in conjunction with lymphoscintigraphy in detecting malignant melanoma metastases in sentinel lymph nodes: a retrospective analysis in 221 patients with malignant melanoma AJCC Stages I and II.

    Science.gov (United States)

    Stoffels, I; Dissemond, J; Poeppel, T; Klötgen, K; Hillen, U; Körber, A; Schadendorf, D; Klode, J

    2012-01-01

    Sentinel lymph node excision (SLNE) for the detection of regional nodal metastases and staging of malignant melanoma has resulted in some controversies in international discussions as it is a surgical intervention with potential morbidity. The present retrospective study seeks to clarify the reliability of preoperative ultrasonography (US) in direct comparison to the result of SLNE and seeks to identify potential advantages of preoperative ultrasound if performed in conjunction with lymphoscintigraphy in detecting malignant melanoma metastases in sentinel lymph node (SLN). We retrospectively analysed data from 221 patients with primary malignant melanoma with a Breslow index of ≥ 1.0 mm. Of the 221 patients, 77.4% (n = 171) had a negative SLN. In 50 patients (22.6%), the histopathological investigation of 71 excised lymph nodes resulted in a positive SLN. The US examination demonstrated a sensitivity of 13.6%, a specificity of 96.9%, a positive predictive value of 97.2% and a negative predictive value of 12.6%. SLNE alone shows a sensitivity of 94%, a specificity of 98.6%, a positive predictive value of 100% and a negative predictive value of 98.3%. Preoperative US in conjunction with dynamic lymphoscintigraphy, followed by SLNE, demonstrated a detecting ratio of 100% (n = 28) for micrometastases and 98.6% (n = 42/43) for macrometastases. In conclusion, this study confirms that preoperative US alone cannot replace the vital information obtained during dynamic lymphoscintigraphy. But preoperative US is an important component of the staging procedure in melanoma patients and has clear advantages when performed in conjunction with dynamic lymphoscintigraphy. Therefore, we recommend preoperative US before every SLNE. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.

  13. Oblique and lateral impact response of the PMHS thorax.

    Science.gov (United States)

    Shaw, Joshua M; Herriott, Rodney G; McFadden, Joseph D; Donnelly, Bruce R; Bolte, John H

    2006-11-01

    This study characterizes the PMHS thoracic response to blunt impact in oblique and lateral directions. A significant amount of data has been collected from lateral impacts conducted on human cadavers. Substantially less data has been collected from impacts that are anterior of lateral in an oblique direction. In the past, data collected from the handful of oblique impact studies were considered to be similar enough to the data from purely lateral impacts such that the oblique data were combined with data from lateral impacts. Defining the biomechanical response of the PMHS thorax to oblique impact is of great importance in side impact vehicle crashes where the loading is often anterior-oblique in direction. Data in this study was obtained from a chestband placed on the thorax at the level of impact to measure thoracic deflection. Two low energy impacts were conducted on each of seven subjects at 2.5 m/s, with one lateral impact and one oblique impact to opposite sides of each PMHS. Data was normalized using the Mertz-Viano method for a two mass system to allow for inter-subject comparisons. Force versus deflection response corridors were generated for the two impact types using an objective mathematical approach and compared to one another. Results were also compared to existing data for oblique and lateral thoracic impacts. The oblique thoracic response in low speed pendulum impacts was found to be different than the lateral thoracic response, in terms of force and deflection. Specifically, the lateral force was greater than the oblique force, and oblique deflection greater than lateral deflection for equal energy impacts.

  14. Three-year follow-up of sentinel node-negative patients with early oral cavity squamous cell carcinoma

    DEFF Research Database (Denmark)

    Sebbesen, Lars; Bilde, Anders; Therkildsen, Marianne

    2014-01-01

    2009, 53 consecutive SNB-negative patients with oral cavity squamous cell carcinoma (SCC) T1 to T2 were accrued. Follow-up was done continuously with the most recent examination in October 2011. The location of the sentinel lymph nodes was determined using dynamic and planar lymphoscintigraphy...

  15. Pelvic digital subtraction catheter angiography-Are routine oblique projections necessary?

    International Nuclear Information System (INIS)

    Rane, Neil; Imam, Atique; Foley, Peter; Timmons, Grace; Uberoi, Raman

    2011-01-01

    The oblique projection is used widely in imaging of the lower vascular tree. Much of the evidence justifying the oblique projection is anecdotal. This study compares the sensitivity of the anteroposterior (AP) projection alone in lower limb vascular catheter angiography to that combined with the oblique projection. 110 digitally subtracted angiograms were analysed initially on AP and subsequently on oblique views. Oblique imaging increases confidence, demonstrates stenoses not seen on AP and changes the diagnosis. This supports the use of the oblique projection in lower limb vascular interventional imaging.

  16. 1.5  kW efficient CW Nd:YAG planar waveguide MOPA laser.

    Science.gov (United States)

    Wang, Juntao; Wu, Zhenhai; Su, Hua; Zhou, Tangjian; Lei, Jun; Lv, Wenqiang; He, Jing; Xu, Liu; Chen, Yuejian; Wang, Dan; Tong, Lixin; Hu, Hao; Gao, Qingsong; Tang, Chun

    2017-08-15

    In this Letter, we report a 1064 nm continuous wave Nd:YAG planar waveguide laser with an output power of 1544 W based on the structure of the master oscillator power amplification. A fiber laser is used as the master oscillator, and diode laser arrays are used as the pump source of the waveguide laser amplifier. The dimension of the waveguide is 1  mm (T)×10  mm (W)×60  mm (L), and the dual end oblique pumping is adopted with different angles. After a single-pass amplification, the power is scaled from 323 to 1544 W with the pump power of 2480 W, leading to an optical-to-optical efficiency of 49%. At the maximum output, the beam quality M 2 are measured to be 2.8 and 7.0 in the guided direction and the unguided direction, respectively. To the best of our knowledge, this is the highest output power of a Nd:YAG planar waveguide laser to date.

  17. The use of Emla gel to ease the pain of intradigital injections during lower limb lymphoscintigraphy

    International Nuclear Information System (INIS)

    Szeto, E.; Loder, A.; Keane, J.

    1999-01-01

    Full text: Thirty patients aged 19-82 years (mean 56) presented to the department for lower limb lymphoscintigraphy. Patients were asked to arrive at the department I h prior to the commencement of their test for the Emla gel (topical anaesthesia) to be applied to the webbing between the 2nd and 4th web spaces on one foot. Patients were asked to rate on a scale of 1-5 (5 being the most painful) the intensity of pain felt in each foot, first when the needles were inserted and second when the colloid was injected. The pain from the needle insertions was usually well tolerated. Only a small number (5/30) of patients felt that the Emla gel diminished the pain. No patients reported any significant difference in the pain felt in each foot when the colloid was injected. This pain was rated as severe in all but one case. The study had a few limiting factors. First, the perception of pain is extremely subjective, although each patient served as his or her own control. Secondly, the patients only had gel applied to one foot and this may have had a placebo effect, although the patients uniformly indicated that there was no significant difference for the severe pain of the colloid injection. In conclusion, Emla gel does not appear to have any significant effect on decreasing the severe pain felt by the interdigital injection of colloid used for lower limb lymphoscintigraphy. Although a small number of patients reported a mild reduction in discomfort from the needle insertions, this discomfort was usually reported as mild and was generally well tolerated

  18. Oblique photon expansion of QED structure functions

    International Nuclear Information System (INIS)

    Chahine, C.

    1986-01-01

    In the oblique photon expansion, the collinear part of photon emission is summed up to all orders in perturbation theory. The number of oblique or non-collinear photons is the expansion order. Unlike in perturbation theory, every term of the expansion is both infrared finite and gauge invariant. The zero oblique photon contribution to the electromagnetic structure tensor in QED is computed in detail. The behaviors of the structure functions F1 and F2 are discussed in the soft and ultra-soft limits

  19. CAIPIRINHA accelerated SPACE enables 10-min isotropic 3D TSE MRI of the ankle for optimized visualization of curved and oblique ligaments and tendons

    Energy Technology Data Exchange (ETDEWEB)

    Kalia, Vivek [University of Vermont Medical Center, Department of Radiology, Burlington, VT (United States); Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Section of Musculoskeletal Radiology, Baltimore, MD (United States); Fritz, Benjamin [University Medical Center Freiburg, Department of Radiology, Freiburg im Breisgau (Germany); Johnson, Rory [Siemens Healthcare USA, Inc, Cary, NC (United States); Gilson, Wesley D. [Siemens Healthcare USA, Inc, Baltimore, MD (United States); Raithel, Esther [Siemens Healthcare GmbH, Erlangen (Germany); Fritz, Jan [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Section of Musculoskeletal Radiology, Baltimore, MD (United States)

    2017-09-15

    To test the hypothesis that a fourfold CAIPIRINHA accelerated, 10-min, high-resolution, isotropic 3D TSE MRI prototype protocol of the ankle derives equal or better quality than a 20-min 2D TSE standard protocol. Following internal review board approval and informed consent, 3-Tesla MRI of the ankle was obtained in 24 asymptomatic subjects including 10-min 3D CAIPIRINHA SPACE TSE prototype and 20-min 2D TSE standard protocols. Outcome variables included image quality and visibility of anatomical structures using 5-point Likert scales. Non-parametric statistical testing was used. P values ≤0.001 were considered significant. Edge sharpness, contrast resolution, uniformity, noise, fat suppression and magic angle effects were without statistical difference on 2D and 3D TSE images (p > 0.035). Fluid was mildly brighter on intermediate-weighted 2D images (p < 0.001), whereas 3D images had substantially less partial volume, chemical shift and no pulsatile-flow artifacts (p < 0.001). Oblique and curved planar 3D images resulted in mildly-to-substantially improved visualization of joints, spring, bifurcate, syndesmotic, collateral and sinus tarsi ligaments, and tendons (p < 0.001, respectively). 3D TSE MRI with CAIPIRINHA acceleration enables high-spatial resolution oblique and curved planar MRI of the ankle and visualization of ligaments, tendons and joints equally well or better than a more time-consuming anisotropic 2D TSE MRI. (orig.)

  20. CAIPIRINHA accelerated SPACE enables 10-min isotropic 3D TSE MRI of the ankle for optimized visualization of curved and oblique ligaments and tendons

    International Nuclear Information System (INIS)

    Kalia, Vivek; Fritz, Benjamin; Johnson, Rory; Gilson, Wesley D.; Raithel, Esther; Fritz, Jan

    2017-01-01

    To test the hypothesis that a fourfold CAIPIRINHA accelerated, 10-min, high-resolution, isotropic 3D TSE MRI prototype protocol of the ankle derives equal or better quality than a 20-min 2D TSE standard protocol. Following internal review board approval and informed consent, 3-Tesla MRI of the ankle was obtained in 24 asymptomatic subjects including 10-min 3D CAIPIRINHA SPACE TSE prototype and 20-min 2D TSE standard protocols. Outcome variables included image quality and visibility of anatomical structures using 5-point Likert scales. Non-parametric statistical testing was used. P values ≤0.001 were considered significant. Edge sharpness, contrast resolution, uniformity, noise, fat suppression and magic angle effects were without statistical difference on 2D and 3D TSE images (p > 0.035). Fluid was mildly brighter on intermediate-weighted 2D images (p < 0.001), whereas 3D images had substantially less partial volume, chemical shift and no pulsatile-flow artifacts (p < 0.001). Oblique and curved planar 3D images resulted in mildly-to-substantially improved visualization of joints, spring, bifurcate, syndesmotic, collateral and sinus tarsi ligaments, and tendons (p < 0.001, respectively). 3D TSE MRI with CAIPIRINHA acceleration enables high-spatial resolution oblique and curved planar MRI of the ankle and visualization of ligaments, tendons and joints equally well or better than a more time-consuming anisotropic 2D TSE MRI. (orig.)

  1. Lymphatics of the cardia of stomach. Examination using RI lymphoscintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yonemura, Yutaka; Katayama, Kanji; Sawa, Toshiharu

    1985-01-01

    The lymphatics of the cardia of stomach was examined using lymphoscintigraphy with technetium 99m colloid in 98 patients with gastric cancer and 4 patients with esophageal cancer. The colloidal Tc-99m was injected into the submucosa of stomach 12 hr before operation with the aid of endoscopy. Each lymph node dissected from the specimens was measured by scintillation counter. Lymph nodes located along the left gastric, splenic and left inferior phrenic arteries were mainly involved in the lymphatics of the cardia of stomach. There was strong relationship between the cardia and the node of number 16. The lymphatics was also present in the mediastinum. These results suggest the necessities of the complete removal of the gastropancreatic mesenteriolum including the left inferior phrenic artery and the extirpation of the regional lymph nodes around the aorta above and below the left renal artery, in addition to the removal of both pancreas and spleen in cases of cardia tumors. Furthermore, in cases of squamous cell carcinoma or adenocarcinoma metastasizing to the intraperitoneal lymph nodes, it seems necessary to extirpate the complete mediastinal lymph nodes. (Namekawa, K.).

  2. Magnetic resonance imaging in congenital superior oblique palsy

    International Nuclear Information System (INIS)

    Sato, Miho; Kondo, Nagako; Awaya, Shinobu; Nomura, Hideki; Yagasaki, Teiji.

    1996-01-01

    MRI examinations were carried out on the defined congenital superior oblique palsy in order to distinguish the congenital and acquired palsies. Subjects were 19 patients diagnosed as congenital and their MRI images of 3 or 5 mm-thick coronary slice were taken. The volume of the oblique muscle was calculated from the images and a comparison was made between the diseased and healthy normal sides. The oblique muscle volume at the diseased side was found reduced in most of congenital superior oblique palsy patients. The reduction was observed even at childhood and was thus considered to be a malformation. Further, it is conceivable that the palsy could be caused by the abnormality in the central nervous system as well as by the present anatomical abnormality. (K.H.)

  3. Lymphatic mapping and sentinel node biopsy in early stage melanoma: study of the first 100 cases in Institut Gustave Roussy; Lymphoscintigraphie et biopsie du ganglion sentinelle dans les melanomes cutanes primitifs: analyse des 100 premiers cas a l'Institut Gustave Roussy

    Energy Technology Data Exchange (ETDEWEB)

    Buffard, V.; Duvillard, P. [Institut Gustave Roussy, Service de Dermatologie, 94 - Villejuif (France); Mamelle, G. [Institut Gustave Roussy, Service de Chirurgie Cervico-faciale, 94 - Villejuif (France); Lumbroso, J.; Ricard, M. [Institut Gustave Roussy, Service de Medecine Nucleaire et de Physique Medicale, 94 - Villejuif (France); Kolb, F.; Sleilati, F. [Institut Gustave Roussy, Service de Chirurgie Plastique, 94 - Villejuif (France); Spatz, A. [Institut Gustave Roussy, Service d' Histopathologie, 94 - Villejuif (France)

    2005-01-15

    Introduction: We report the data of the first 100 patients who underwent sentinel lymph node biopsy (SLND) in our institution using lymphoscintigraphy only. Patients and methods: From 1998 to 2000, 100 consecutive patients (53 men and 47 women) with stage I or II melanoma (mean Breslow: 3.11 mm) underwent a SLND. Localisation of the sentinel node was performed by preoperative lymphoscintigraphy and hand held gamma probe detection. The sentinel node was examined by routine histology and immunohistochemistry for PS100 and HMB-45. If the sentinel node contained tumor cells, a complete lymphadenectomy was performed. Results: Lymphoscintigraphy was performed for 97 patients. The SLN was identified in 97% of cases (94/97) and excised in 95% of cases (92/97). The rate of SLN metastasis was 19/92 patients (21%), correlated with Breslow index (< 1.5 mm: 5%, 1.5-4 mm: 15%, > 4 mm: 46%). A mean number of 1.81 lymph node per patient was analysed. The mean follow-up was 26 months with a relapse in 14 patients, 5 of them having a metastatic sentinel node. Three patients had a recurrence at the site of the SLND although they had initially a negative sentinel node. Conclusion: The identification and metastatic rates of sentinel nodes are similar to those of the literature. More studies are needed to determine whether lymphoscintigraphy alone is efficient for successful SLND in melanoma. (author)

  4. Photo guided sentinel node mapping in breast cancer using marker free photo gamma fusion lymphoscintigraphy

    International Nuclear Information System (INIS)

    Lee, Eun Seong; Chun, In Kook; Ha, Seungn Gyun; Yoon, Hai Jeon; Jung, So Youn; Lee, See Youn; Kim, Seok Won; Lee, Eun Sook; Kim, Tae Yoon; Kim, Kwang Gi; Kim, Tae Sung; Kim, Seok Ki; Lee, Byung Il

    2012-01-01

    Photo gamma fusion lymphoscintigraphy (PGFLS) was developed by overlying a conventional planar gamma image on a photograph for the guidance of sentinel node biopsy. The feasibility and accuracy of PGFLS was assessed in breast cancer patients. A digital camera and a gamma camera were coordinated to obtain photograph and gamma images from the same angle. Using the distance to the object and calibration acquisition with a flat phantom and radioactive markers, PGFLS was performed both in phantom and in patients without fiducial markers. Marker free PGFLS was verified using flat phantom, anthropomorphic phantom with markers simulating sentinel nodes and breast cancer patients. In addition, the depth of the radioactive marker or sentinel node was calculated using two gamma images taken at right angles. The feasibility and accuracy of PGFLS were assessed in terms of mismatch errors of co registration and depth with reference to the data from SPECT/CT. The mismatch error was less than 6mm in the flat phantom image at a distance from 50 to 62cm without misalignment. In the anthropomorphic phantom study, co registration error was 0.42±0.29cm; depth error was 0.51±0.37cm, which was well correlated with the reference value on SPECT/CT (x scale: R'2'=0.99, p<0.01; y scale: R'2'=0.09, p<0.01; depth: R'2'=0.99, p<0.01). In ten patients with breast cancer referred for lympho SPECT/CT, PGFSL enabled photo guided sentinel lymph node mapping with acceptable accuracy (co-registration error, 0.47±0.24cm; depth error, 1.20±0.41cm). The results from PGFSL showed close correlation with those from SPECT/CT (x scale: R'2'=0.99, p<0.01; y scale: R'2'=0.98, p<0/01; depth: R'2'=0.77, p<0.01). The novel and convenient PGFLS technique is clinically feasible, showing acceptable accuracy and providing additional visual and quantitative information for sentinel lymph node mapping. This approach will facilitate photo guided sentinel lymph node dissection in breast cancer

  5. Motor mechanisms of vertical fusion in individuals with superior oblique paresis.

    Science.gov (United States)

    Mudgil, Ananth V; Walker, Mark; Steffen, Heimo; Guyton, David L; Zee, David S

    2002-06-01

    We wanted to determine the mechanisms of motor vertical fusion in patients with superior oblique paresis and to correlate these mechanisms with surgical outcomes. Ten patients with superior oblique paresis underwent 3-axis, bilateral, scleral search coil eye movement recordings. Eye movements associated with fusion were analyzed. Six patients had decompensated congenital superior oblique paresis and 4 had acquired superior oblique paresis. All patients with acquired superior oblique paresis relied predominantly on the vertical rectus muscles for motor fusion. Patients with congenital superior oblique paresis were less uniform in their mechanisms for motor fusion: 2 patients used predominantly the oblique muscles, 2 patients used predominantly the vertical recti, and 2 patients used predominantly the superior oblique in the hyperdeviated eye and the superior rectus in the hypodeviated eye. The last 2 patients developed the largest changes in torsional eye alignment relative to changes in vertical eye alignment and were the only patients to develop symptomatic surgical overcorrections. There are 3 different mechanisms for vertical fusion in individuals with superior oblique paresis, with the predominant mechanism being the vertical recti. A subset of patients with superior oblique paresis uses predominantly the superior oblique muscle in the hyperdeviated paretic eye and the superior rectus muscle in the fellow eye for fusion. This results in intorsion of both eyes, causing a large change in torsional alignment. The consequent cyclodisparity, in addition to the existing vertical deviation, may make fusion difficult. The differing patterns of vertical fusional vergence may have implications for surgical treatment.

  6. Camere aeree oblique: sistemi, applicazioni e prospettive future

    Directory of Open Access Journals (Sweden)

    Fabio Remondino

    2014-10-01

    Full Text Available The use of oblique imagery has become a standard for many civil and mapping applications, thanks to the development of airborne digital multi-camera systems, as proposed by many companies. The indisputable virtue of oblique photography lies in its simplicity of interpretation and understanding for inexperienced users allowing their use of oblique images in very different applications, such as building detection and reconstruction, building structural damage classification, road land updating and administration services, etc. We report an overview of the actual oblique commercial systems and the workflow for the automated orientation and dense matching of large image blocks. Perspectives, potentialities, pitfalls and suggestions for achieving satisfactory results are given too.

  7. Fabrication and Characteristics of ZnO/OAD-InN/PbPc Hybrid Solar Cells Prepared by Oblique-Angle Deposition

    Directory of Open Access Journals (Sweden)

    Lung-Chien Chen

    2012-08-01

    Full Text Available In this work, lead phthalocyanine (PbPc and ZnO/InN inorganic semiconductor films prepared by oblique-angle deposition (OAD were layered to form heterojunction organic/inorganic hybrid photovoltaic solar cells. Among the available organic materials, phthalocyanines, particularly the non-planar ones such as PbPc, are notable for their absorption in the visible and near infrared regions. The organic/inorganic hybrid solar cells fabricated on ZnO/OAD-InN/PbPc showed short-circuit current density (JSC, open-circuit voltage (VOC, and power conversion efficiencies (η of 1.2 mA/cm2, 0.6 V and 0.144%, respectively.

  8. Reaching to virtual targets: The oblique effect reloaded in 3-D.

    Science.gov (United States)

    Kaspiris-Rousellis, Christos; Siettos, Constantinos I; Evdokimidis, Ioannis; Smyrnis, Nikolaos

    2017-02-20

    Perceiving and reproducing direction of visual stimuli in 2-D space produces the visual oblique effect, which manifests as increased precision in the reproduction of cardinal compared to oblique directions. A second cognitive oblique effect emerges when stimulus information is degraded (such as when reproducing stimuli from memory) and manifests as a systematic distortion where reproduced directions close to the cardinal axes deviate toward the oblique, leading to space expansion at cardinal and contraction at oblique axes. We studied the oblique effect in 3-D using a virtual reality system to present a large number of stimuli, covering the surface of an imaginary half sphere, to which subjects had to reach. We used two conditions, one with no delay (no-memory condition) and one where a three-second delay intervened between stimulus presentation and movement initiation (memory condition). A visual oblique effect was observed for the reproduction of cardinal directions compared to oblique, which did not differ with memory condition. A cognitive oblique effect also emerged, which was significantly larger in the memory compared to the no-memory condition, leading to distortion of directional space with expansion near the cardinal axes and compression near the oblique axes on the hemispherical surface. This effect provides evidence that existing models of 2-D directional space categorization could be extended in the natural 3-D space. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  9. Natural Vibration of a Beam with a Breathing Oblique Crack

    Directory of Open Access Journals (Sweden)

    Yijiang Ma

    2017-01-01

    Full Text Available An analytical method is proposed to calculate the natural frequency of a cantilever beam with a breathing oblique crack. A double-linear-springs-model is developed in the modal analysis process to describe the breathing oblique crack, and the breathing behaviour of the oblique crack is objectively simulated. The finite element method (FEM analysis software ABAQUS is used to calculate the geometric correction factors when the cracked plate is subjected to a pure bending moment at different oblique crack angles and relative depths. The Galerkin method is applied to simplify the cracked beam to a single degree of freedom system, allowing the natural frequency of the beam with the breathing oblique crack to be calculated. Compared with the natural frequencies of the breathing oblique cracked beam obtained using the ABAQUS FEM method, the proposed analytical method exhibits a high computational accuracy, with a maximum error of only 4.65%.

  10. Assessment Of An Oblique ECE Diagnostic For ITER

    International Nuclear Information System (INIS)

    Taylor, G.; Harvey, R.W.

    2009-01-01

    A systematic disagreement between the electron temperature measured by electron cyclotron emission (TECE) and laser Thomson scattering (TTS), that increases with TECE, is observed in JET and TFTR plasmas, such that TECE ∼1.2 TTS when TECE ∼10 keV. The disagreement is consistent with a non-Maxwellian distortion in the bulk electron momentum distribution. ITER is projected to operate with Te(0) ∼ 20-40 keV so the disagreement between TECE and TTS could be > 50%, with significant physics implications. The GENRAY ray tracing code predicts that a two-view ECE system, with perpendicular and moderately oblique viewing antennas, would be sufficient to reconstruct a two-temperature bulk distribution. If the electron momentum distribution remains Maxwellian the moderately oblique view could still be used to measure Te(R). A viewing dump will not be required for the oblique view and plasma refraction will be minimal. The oblique view has a similar radial resolution to the perpendicular view, but with some reduction in radial coverage. Oblique viewing angles of up to 20 o can be implemented without a major revision to the front end of the existing ITER ECE diagnostic design.

  11. Reduced Oblique Effect in Children with Autism Spectrum Disorders (ASD)

    Science.gov (United States)

    Sysoeva, Olga V.; Davletshina, Maria A.; Orekhova, Elena V.; Galuta, Ilia A.; Stroganova, Tatiana A.

    2016-01-01

    People are very precise in the discrimination of a line orientation relative to the cardinal (vertical and horizontal) axes, while their orientation discrimination sensitivity along the oblique axes is less refined. This difference in discrimination sensitivity along cardinal and oblique axes is called the “oblique effect.” Given that the oblique effect is a basic feature of visual processing with an early developmental origin, its investigation in children with Autism Spectrum Disorder (ASD) may shed light on the nature of visual sensory abnormalities frequently reported in this population. We examined line orientation sensitivity along oblique and vertical axes in a sample of 26 boys with ASD (IQ > 68) and 38 typically developing (TD) boys aged 7–15 years, as well as in a subsample of carefully IQ-matched ASD and TD participants. Children were asked to detect the direction of tilt of a high-contrast black-and-white grating relative to vertical (90°) or oblique (45°) templates. The oblique effect was reduced in children with ASD as compared to TD participants, irrespective of their IQ. This reduction was due to poor orientation sensitivity along the vertical axis in ASD children, while their ability to discriminate line orientation along the oblique axis was unaffected. We speculate that this deficit in sensitivity to vertical orientation may reflect disrupted mechanisms of early experience-dependent learning that takes place during the critical period for orientation selectivity. PMID:26834540

  12. Lymphoscintigraphy of the lower limbs: a retrospective study of 154 cases from March 2009 to June 2010

    International Nuclear Information System (INIS)

    Barral, Carlyle Marques; Carvalho, Luciana Araujo; Stehling, Alexandre Pace; Silva, Antonio Carlos Moura da; Castro, Atena Cipriano; Ivo, Claudio Santana; Korman, Daniel Einstoss; Couto, Eneida de Melo; Magalhaes, Leonardo Neuenschwander; Felix, Marco Tulio Marques; Machado, Fernando Santana

    2013-01-01

    Introduction: Lymphoscintigraphy of the lower limbs (LLL) is an effective method to assess lymphatic function. Objective: to present the case of 154 patients undergoing LLL between March 2009 and June 2010. Methods: Images of the pelvis and lower limbs were acquired after simultaneous intradermal administration of 1.0 mCi of 99mTc-Dextran 500 in 0.1mL in the interdigital space of the first and second toes, bilaterally. Results: 129 (83.77%) patients were female, mean age was 51.48 years, with 32 patients (20.78%) aged between 40 and 49 years. 58 patients (37.66%) had body mass index between 25 and 30 kg/m², 92 patients (59.74%) reported edema, lymphedema or swelling as the reason for examination. 93 patients (60.39%) without previous vascular surgery or procedure, 108 patients (70.13%) without previous inflammation, erysipelas or trauma. 103 patients (66.88%) presented with bilateral swelling upon examination, with 48 patients (31.17%) reporting edema that worsened in the evening. 77 patients (50%) with symptoms for over a year. 31 patients (20.13%) were hypertensive. Scintigraphic findings: 149 patients (96.75%) with some abnormality caracteupon examination, 38 with severe bilateral delay in lymphatic transit time, 85 (55.19%) with normo functioning lymph nodes, 62 patients with bilateral radiotracer drainage via small saphenous veins, 84 patients (54.55%) without collateral vessels, 92 (59.74%) without lymphatic retention, 85 patients (55.19%) without dermal backflow. 15 patients (9.74%) showed lymph nodes in the popliteal region. Conclusions: lower limb lymphoscintigraphy is available as a method to detect lymphedema and changes in lymphatic drainage, and is important for initial investigative screenings, early stage assessments of edema, and for monitoring therapeutic, clinical or surgical interventions. (author)

  13. Lymphoscintigraphy of the lower limbs: a retrospective study of 154 cases from March 2009 to June 2010

    Energy Technology Data Exchange (ETDEWEB)

    Barral, Carlyle Marques; Carvalho, Luciana Araujo; Stehling, Alexandre Pace; Silva, Antonio Carlos Moura da; Castro, Atena Cipriano; Ivo, Claudio Santana; Korman, Daniel Einstoss; Couto, Eneida de Melo; Magalhaes, Leonardo Neuenschwander; Felix, Marco Tulio Marques; Machado, Fernando Santana [ECOAR Medicina Diagnostica, Belo Horizonte, MG (Brazil)

    2013-07-01

    Introduction: Lymphoscintigraphy of the lower limbs (LLL) is an effective method to assess lymphatic function. Objective: to present the case of 154 patients undergoing LLL between March 2009 and June 2010. Methods: Images of the pelvis and lower limbs were acquired after simultaneous intradermal administration of 1.0 mCi of 99mTc-Dextran 500 in 0.1mL in the interdigital space of the first and second toes, bilaterally. Results: 129 (83.77%) patients were female, mean age was 51.48 years, with 32 patients (20.78%) aged between 40 and 49 years. 58 patients (37.66%) had body mass index between 25 and 30 kg/m², 92 patients (59.74%) reported edema, lymphedema or swelling as the reason for examination. 93 patients (60.39%) without previous vascular surgery or procedure, 108 patients (70.13%) without previous inflammation, erysipelas or trauma. 103 patients (66.88%) presented with bilateral swelling upon examination, with 48 patients (31.17%) reporting edema that worsened in the evening. 77 patients (50%) with symptoms for over a year. 31 patients (20.13%) were hypertensive. Scintigraphic findings: 149 patients (96.75%) with some abnormality caracteupon examination, 38 with severe bilateral delay in lymphatic transit time, 85 (55.19%) with normo functioning lymph nodes, 62 patients with bilateral radiotracer drainage via small saphenous veins, 84 patients (54.55%) without collateral vessels, 92 (59.74%) without lymphatic retention, 85 patients (55.19%) without dermal backflow. 15 patients (9.74%) showed lymph nodes in the popliteal region. Conclusions: lower limb lymphoscintigraphy is available as a method to detect lymphedema and changes in lymphatic drainage, and is important for initial investigative screenings, early stage assessments of edema, and for monitoring therapeutic, clinical or surgical interventions. (author)

  14. Orientation Strategies for Aerial Oblique Images

    Science.gov (United States)

    Wiedemann, A.; Moré, J.

    2012-07-01

    Oblique aerial images become more and more distributed to fill the gap between vertical aerial images and mobile mapping systems. Different systems are on the market. For some applications, like texture mapping, precise orientation data are required. One point is the stable interior orientation, which can be achieved by stable camera systems, the other a precise exterior orientation. A sufficient exterior orientation can be achieved by a large effort in direct sensor orientation, whereas minor errors in the angles have a larger effect than in vertical imagery. The more appropriate approach is by determine the precise orientation parameters by photogrammetric methods using an adapted aerial triangulation. Due to the different points of view towards the object the traditional aerotriangulation matching tools fail, as they produce a bunch of blunders and require a lot of manual work to achieve a sufficient solution. In this paper some approaches are discussed and results are presented for the most promising approaches. We describe a single step approach with an aerotriangulation using all available images; a two step approach with an aerotriangulation only of the vertical images plus a mathematical transformation of the oblique images using the oblique cameras excentricity; and finally the extended functional model for a bundle block adjustment considering the mechanical connection between vertical and oblique images. Beside accuracy also other aspects like efficiency and required manual work have to be considered.

  15. The use of a portable gamma camera for preoperative lymphatic mapping: a comparison with a conventional gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Vidal-Sicart, Sergi; Paredes, Pilar [Hospital Clinic Barcelona, Nuclear Medicine Department (CDIC), Barcelona (Spain); Institut d' Investigacio Biomedica Agusti Pi Sunyer (IDIBAPS), Barcelona (Spain); Vermeeren, Lenka; Valdes-Olmos, Renato A. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital (NKI-AVL), Nuclear Medicine Department, Amsterdam (Netherlands); Sola, Oriol [Hospital Clinic Barcelona, Nuclear Medicine Department (CDIC), Barcelona (Spain)

    2011-04-15

    Planar lymphoscintigraphy is routinely used for preoperative sentinel node visualization, but large gamma cameras are not always available. We evaluated the reproducibility of lymphatic mapping with a smaller and portable gamma camera. In two centres, 52 patients with breast cancer received preoperative lymphoscintigraphy with a conventional gamma camera with a field of view of 40 x 40 cm. Static anterior and lateral images were performed at 15 min, 2 h and 4 h after injection of the radiotracer ({sup 99m}Tc-nanocolloid). At 2 h after injection, anterior and oblique images were also performed with a portable gamma camera (Sentinella, Oncovision) positioned to obtain a field of view of 20 x 20 cm. Visualization of lymphatic drainage on conventional images and images with the portable device were compared for number of nodes depicted, their intensity and localization of sentinel nodes. The images performed with the conventional gamma camera depicted sentinel nodes in 94%, while the portable gamma camera showed drainage in 73%. There was however no significant difference in visualization between the two devices when a lead shield was used to mask the injection area in 43 patients (95 vs 88%, p = 0.25). Second-echelon nodes were visualized in 62% of the patients with the conventional gamma camera and in 29% of the cases with the portable gamma camera. Preoperative imaging with a portable gamma camera fitted with a pinhole collimator to obtain a field of view of 20 x 20 cm is able to depict sentinel nodes in 88% of the cases, if a lead shield is used to mask the injection site. This device may be useful in centres without the possibility to perform a preoperative image. (orig.)

  16. The use of a portable gamma camera for preoperative lymphatic mapping: a comparison with a conventional gamma camera

    International Nuclear Information System (INIS)

    Vidal-Sicart, Sergi; Paredes, Pilar; Vermeeren, Lenka; Valdes-Olmos, Renato A.; Sola, Oriol

    2011-01-01

    Planar lymphoscintigraphy is routinely used for preoperative sentinel node visualization, but large gamma cameras are not always available. We evaluated the reproducibility of lymphatic mapping with a smaller and portable gamma camera. In two centres, 52 patients with breast cancer received preoperative lymphoscintigraphy with a conventional gamma camera with a field of view of 40 x 40 cm. Static anterior and lateral images were performed at 15 min, 2 h and 4 h after injection of the radiotracer ( 99m Tc-nanocolloid). At 2 h after injection, anterior and oblique images were also performed with a portable gamma camera (Sentinella, Oncovision) positioned to obtain a field of view of 20 x 20 cm. Visualization of lymphatic drainage on conventional images and images with the portable device were compared for number of nodes depicted, their intensity and localization of sentinel nodes. The images performed with the conventional gamma camera depicted sentinel nodes in 94%, while the portable gamma camera showed drainage in 73%. There was however no significant difference in visualization between the two devices when a lead shield was used to mask the injection area in 43 patients (95 vs 88%, p = 0.25). Second-echelon nodes were visualized in 62% of the patients with the conventional gamma camera and in 29% of the cases with the portable gamma camera. Preoperative imaging with a portable gamma camera fitted with a pinhole collimator to obtain a field of view of 20 x 20 cm is able to depict sentinel nodes in 88% of the cases, if a lead shield is used to mask the injection site. This device may be useful in centres without the possibility to perform a preoperative image. (orig.)

  17. Effects of Extreme Obliquity Variations on the Habitability of Exoplanets

    Science.gov (United States)

    Armstrong, J. C.; Barnes, R.; Domagal-Goldman, S.; Breiner, J.; Quinn, T. R.; Meadows, V. S.

    2014-01-01

    We explore the impact of obliquity variations on planetary habitability in hypothetical systems with high mutual inclination. We show that large-amplitude, high-frequency obliquity oscillations on Earth-like exoplanets can suppress the ice-albedo feedback, increasing the outer edge of the habitable zone. We restricted our exploration to hypothetical systems consisting of a solar-mass star, an Earth-mass planet at 1 AU, and 1 or 2 larger planets. We verified that these systems are stable for 108 years with N-body simulations and calculated the obliquity variations induced by the orbital evolution of the Earth-mass planet and a torque from the host star. We ran a simplified energy balance model on the terrestrial planet to assess surface temperature and ice coverage on the planet's surface, and we calculated differences in the outer edge of the habitable zone for planets with rapid obliquity variations. For each hypothetical system, we calculated the outer edge of habitability for two conditions: (1) the full evolution of the planetary spin and orbit and (2) the eccentricity and obliquity fixed at their average values. We recovered previous results that higher values of fixed obliquity and eccentricity expand the habitable zone, but we also found that obliquity oscillations further expand habitable orbits in all cases. Terrestrial planets near the outer edge of the habitable zone may be more likely to support life in systems that induce rapid obliquity oscillations as opposed to fixed-spin planets. Such planets may be the easiest to directly characterize with space-borne telescopes.

  18. Effects of extreme obliquity variations on the habitability of exoplanets.

    Science.gov (United States)

    Armstrong, J C; Barnes, R; Domagal-Goldman, S; Breiner, J; Quinn, T R; Meadows, V S

    2014-04-01

    We explore the impact of obliquity variations on planetary habitability in hypothetical systems with high mutual inclination. We show that large-amplitude, high-frequency obliquity oscillations on Earth-like exoplanets can suppress the ice-albedo feedback, increasing the outer edge of the habitable zone. We restricted our exploration to hypothetical systems consisting of a solar-mass star, an Earth-mass planet at 1 AU, and 1 or 2 larger planets. We verified that these systems are stable for 10(8) years with N-body simulations and calculated the obliquity variations induced by the orbital evolution of the Earth-mass planet and a torque from the host star. We ran a simplified energy balance model on the terrestrial planet to assess surface temperature and ice coverage on the planet's surface, and we calculated differences in the outer edge of the habitable zone for planets with rapid obliquity variations. For each hypothetical system, we calculated the outer edge of habitability for two conditions: (1) the full evolution of the planetary spin and orbit and (2) the eccentricity and obliquity fixed at their average values. We recovered previous results that higher values of fixed obliquity and eccentricity expand the habitable zone, but we also found that obliquity oscillations further expand habitable orbits in all cases. Terrestrial planets near the outer edge of the habitable zone may be more likely to support life in systems that induce rapid obliquity oscillations as opposed to fixed-spin planets. Such planets may be the easiest to directly characterize with space-borne telescopes.

  19. Obliquity Modulation of the Incoming Solar Radiation

    Science.gov (United States)

    Liu, Han-Shou; Smith, David E. (Technical Monitor)

    2001-01-01

    Based on a basic principle of orbital resonance, we have identified a huge deficit of solar radiation induced by the combined amplitude and frequency modulation of the Earth's obliquity as possibly the causal mechanism for ice age glaciation. Including this modulation effect on solar radiation, we have performed model simulations of climate change for the past 2 million years. Simulation results show that: (1) For the past 1 million years, temperature fluctuation cycles were dominated by a 100-Kyr period due to amplitude-frequency resonance effect of the obliquity; (2) From 2 to 1 million years ago, the amplitude-frequency interactions. of the obliquity were so weak that they were not able to stimulate a resonance effect on solar radiation; (3) Amplitude and frequency modulation analysis on solar radiation provides a series of resonance in the incoming solar radiation which may shift the glaciation cycles from 41-Kyr to 100-Kyr about 0.9 million years ago. These results are in good agreement with the marine and continental paleoclimate records. Thus, the proposed climate response to the combined amplitude and frequency modulation of the Earth's obliquity may be the key to understanding the glaciation puzzles in paleoclimatology.

  20. 33 CFR 118.90 - Bridges crossing channel obliquely.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Bridges crossing channel obliquely. 118.90 Section 118.90 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY BRIDGES BRIDGE LIGHTING AND OTHER SIGNALS § 118.90 Bridges crossing channel obliquely. Bridges...

  1. Diagnosis the metastatic sentinel node with Tc-99m-MIBI

    International Nuclear Information System (INIS)

    Georgiev-Predic, M.; Predic, P.; Karner, I.; Dodig, D.

    2002-01-01

    Aim: The purpose of this study was to analyse the occurrence of visualisation malignancy of sentinel node during preoperative lymphoscintigraphy in breast cancer. To precisely diagnose the metastatic sentinel node is very difficult. Material and Methods:Preoperative lymphoscintigraphy was performed in 47 patients with breast cancer after injection of Tc-99m-MIBI. We injected 20-40 MBq Tc-99m-MIBI peritumoral. Anterior and prone lateral planar images were obtained 2h, 4h, 6h and 20h after injection. The uptake were in region of sentinel node calculed. The sentinel node was intraoperatively identified and histologically analysed. Results: In 27 patients with intraoperatively detected metastatic sentinel node was in 25 patients increased uptake in sentinel node on scintigrams after 20h detected. In 20 patients with intraoperatively non detected metastatic sentinel node was in 19 patients increased uptake on scintigrams ower 2h-6h detected. Conclusion: The results indicated that is lymphoscintigraphy with Tc-99m-MIBI is a new method for detection the preoperatively metastatic sentinel node

  2. Rotation, narrowing and preferential reactivation of brittle structures during oblique rifting

    Science.gov (United States)

    Huismans, R. S.; Duclaux, G.; May, D.

    2017-12-01

    Occurrence of multiple faults populations with contrasting orientations in oblique continental rifts and passive margins has long sparked debate about relative timing of deformation events and tectonic interpretations. Here, we use high-resolution three-dimensional thermo-mechanical numerical modeling to characterize the evolution of the structural style associated with moderately oblique rifting in the continental lithosphere. Automatic analysis of the distribution of active extensional shears at the surface of the model demonstrates a characteristic deformation sequence. We show that upon localization, Phase 1 wide oblique en-échelon grabens develop, limited by extensional shears oriented orthogonal to σ3. Subsequent widening of the grabens is accompanied by a progressive rotation of the Phase 1 extensional shears that become sub-orthogonal the plate motion direction. Phase 2 is marked by narrowing of active deformation resulting from thinning of the continental lithosphere and development of a second-generation of extensional shears. During Phase 2 deformation localizes both on plate motion direction-orthogonal structures that reactivate rotated Phase 1 shears, and on new oblique structures orthogonal to σ3. Finally, Phase 3 consists in the oblique rupture of the continental lithosphere and produces an oceanic domain where oblique ridge segments are linked with highly oblique accommodation zones. We conclude that while new structures form normal to σ3 in an oblique rift, progressive rotation and long-term reactivation of Phase 1 structures promotes orthorhombic fault systems, critical to accommodate upper crustal extension and control oblique passive margin architecture. The distribution, orientation, and evolution of frictional-plastic structures observed in our models is remarkably similar to documented fault populations in the Gulf of Aden conjugate passive margins, which developed in moderately oblique extensional settings.

  3. Climate Dynamics and Hysteresis at Low and High Obliquity

    Science.gov (United States)

    Colose, C.; Del Genio, A. D.; Way, M.

    2017-12-01

    We explore the large-scale climate dynamics at low and high obliquity for an Earth-like planet using the ROCKE-3D (Resolving Orbital and Climate Keys of Earth and Extraterrestrial Environments with Dynamics) 3-D General Circulation model being developed at NASA GISS as part of the Nexus for Exoplanet System Science (NExSS) initiative. We highlight the role of ocean heat storage and transport in determining the seasonal cycle at high obliquity, and describe the large-scale circulation and resulting regional climate patterns using both aquaplanet and Earth topographical boundary conditions. Finally, we contrast the hysteresis structure to varying CO2 concentration for a low and high obliquity planet near the outer edge of the habitable zone. We discuss the prospects for habitability for a high obliquity planet susceptible to global glaciation.

  4. Validity of medium-energy collimator for sentinel lymphoscintigraphy imaging

    International Nuclear Information System (INIS)

    Tsushima, Hiroyuki; Yamanaga, Takashi; Shimonishi, Yoshihiro; Kosakai, Kazuhisa; Takayama, Teruhiko; Kizu, Hiroto; Noguchi, Atsushi; Onoguchi, Masahisa

    2007-01-01

    For lymphoscintigraphy to detect sentinel lymph node (SLN) in the breast cancer, the lead shielding of the injection site is often used to avoid artifacts, but the method tends to cover the neighborhood SLN. To exclude this defect, authors developed ME (medium-energy) method where ME collimator and energy setting shifted to its higher region were employed. This paper described the development and validity evaluation of the ME method. Performed were examinations with 3 acrylic phantoms of the injection site (IS), LN and combination of IS+LN (CB): IS was a cylinder, containing 40 MBq of 99m Tc-pertechnetate and LN, a plate with 30 sealed holes having 0.78-400 kBq. CB phantom consisted from LN-simulating holes (each, 40 kBq) placed linearly around the center of IS in H and S directions. Imaging was conducted with 2 kinds of 2-detector gamma camera, FORTE (ADAGA) and DSX rectangular (Sopha Medical Corp.). CB phantom was found optimally visualized by ME collimator at 146, rather than 141, keV. In clinic, 99m Tc-Sn-colloid 40 MBq was given near the tumor of a patient and imaging was done with or without the lead shield with FORTE equipped with low energy high-resolution or ME collimator for their comparison. The present ME method described above set at 146 keV was found to give the image with excellent contrast and without false positive when compared with the lead shield method hitherto. (R.T.)

  5. Inferior Oblique Overaction: Anterior Transposition Versus Myectomy.

    Science.gov (United States)

    Rajavi, Zhale; Feizi, Mohadeseh; Behradfar, Narges; Yaseri, Mehdi; Sayanjali, Shima; Motevaseli, Tahmine; Sabbaghi, Hamideh; Faghihi, Mohammad

    2017-07-01

    To compare the efficacy of inferior oblique myectomy and anterior transposition for correcting inferior oblique overaction (IOOA). This retrospective study was conducted on 56 patients with IOOA who had either myectomy or anterior transposition of the inferior oblique muscle from 2010 to 2015. The authors compared preoperative and postoperative inferior oblique muscle function grading (-4 to +4) as the main outcome measure and vertical and horizontal deviation, dissociated vertical deviation (DVD), and A- and V-pattern between the two surgical groups as secondary outcomes. A total of 99 eyes of 56 patients with a mean age of 5.9 ± 6.5 years were included (47 eyes in the myectomy group and 52 eyes in the anterior transposition group). There were no differences in preoperative best corrected visual acuity, amblyopia, spherical equivalent, and primary versus secondary IOOA between the two groups. Both surgical procedures were effective in reducing IOOA and satisfactory results were similar between the two groups: 61.7% and 67.3% in the myectomy and anterior transposition groups, respectively (P = .56). After adjustment for the preoperative DVD, there was no statistically significant difference between the two groups postoperatively. The preoperative hypertropia was 6 to 14 and 6 to 18 prism diopters (PD) in the myectomy and anterior transposition groups, respectively. After surgery, no patient had a vertical deviation greater than 5 PD. Both the inferior oblique myectomy and anterior transposition procedures are effective in reducing IOOA with similar satisfactory results. DVD and hypertropia were also corrected similarly by these two surgical procedures. [J Pediatr Ophthalmol Strabismus. 2017;54(4):232-237.]. Copyright 2017, SLACK Incorporated.

  6. Injury risk functions for frontal oblique collisions.

    Science.gov (United States)

    Andricevic, Nino; Junge, Mirko; Krampe, Jonas

    2018-03-09

    The objective of this article was the construction of injury risk functions (IRFs) for front row occupants in oblique frontal crashes and a comparison to IRF of nonoblique frontal crashes from the same data set. Crashes of modern vehicles from GIDAS (German In-Depth Accident Study) were used as the basis for the construction of a logistic injury risk model. Static deformation, measured via displaced voxels on the postcrash vehicles, was used to calculate the energy dissipated in the crash. This measure of accident severity was termed objective equivalent speed (oEES) because it does not depend on the accident reconstruction and thus eliminates reconstruction biases like impact direction and vehicle model year. Imputation from property damage cases was used to describe underrepresented low-severity crashes-a known shortcoming of GIDAS. Binary logistic regression was used to relate the stimuli (oEES) to the binary outcome variable (injured or not injured). IRFs for the oblique frontal impact and nonoblique frontal impact were computed for the Maximum Abbreviated Injury Scale (MAIS) 2+ and 3+ levels for adults (18-64 years). For a given stimulus, the probability of injury for a belted driver was higher in oblique crashes than in nonoblique frontal crashes. For the 25% injury risk at MAIS 2+ level, the corresponding stimulus for oblique crashes was 40 km/h but it was 64 km/h for nonoblique frontal crashes. The risk of obtaining MAIS 2+ injuries is significantly higher in oblique crashes than in nonoblique crashes. In the real world, most MAIS 2+ injuries occur in an oEES range from 30 to 60 km/h.

  7. Oblique Multi-Camera Systems - Orientation and Dense Matching Issues

    Science.gov (United States)

    Rupnik, E.; Nex, F.; Remondino, F.

    2014-03-01

    The use of oblique imagery has become a standard for many civil and mapping applications, thanks to the development of airborne digital multi-camera systems, as proposed by many companies (Blomoblique, IGI, Leica, Midas, Pictometry, Vexcel/Microsoft, VisionMap, etc.). The indisputable virtue of oblique photography lies in its simplicity of interpretation and understanding for inexperienced users allowing their use of oblique images in very different applications, such as building detection and reconstruction, building structural damage classification, road land updating and administration services, etc. The paper reports an overview of the actual oblique commercial systems and presents a workflow for the automated orientation and dense matching of large image blocks. Perspectives, potentialities, pitfalls and suggestions for achieving satisfactory results are given. Tests performed on two datasets acquired with two multi-camera systems over urban areas are also reported.

  8. Obliquity Variations of Habitable Zone Planets Kepler-62f and Kepler-186f

    Science.gov (United States)

    Shan, Yutong; Li, Gongjie

    2018-06-01

    Obliquity variability could play an important role in the climate and habitability of a planet. Orbital modulations caused by planetary companions and the planet’s spin axis precession due to the torque from the host star may lead to resonant interactions and cause large-amplitude obliquity variability. Here we consider the spin axis dynamics of Kepler-62f and Kepler-186f, both of which reside in the habitable zone around their host stars. Using N-body simulations and secular numerical integrations, we describe their obliquity evolution for particular realizations of the planetary systems. We then use a generalized analytic framework to characterize regions in parameter space where the obliquity is variable with large amplitude. We find that the locations of variability are fine-tuned over the planetary properties and system architecture in the lower-obliquity regimes (≲40°). As an example, assuming a rotation period of 24 hr, the obliquities of both Kepler-62f and Kepler-186f are stable below ∼40°, whereas the high-obliquity regions (60°–90°) allow moderate variabilities. However, for some other rotation periods of Kepler-62f or Kepler-186f, the lower-obliquity regions could become more variable owing to resonant interactions. Even small deviations from coplanarity (e.g., mutual inclinations ∼3°) could stir peak-to-peak obliquity variations up to ∼20°. Undetected planetary companions and/or the existence of a satellite could also destabilize the low-obliquity regions. In all cases, the high-obliquity region allows for moderate variations, and all obliquities corresponding to retrograde motion (i.e., >90°) are stable.

  9. Obliquely propagating dust-density waves

    International Nuclear Information System (INIS)

    Piel, A.; Arp, O.; Klindworth, M.; Melzer, A.

    2008-01-01

    Self-excited dust-density waves are experimentally studied in a dusty plasma under microgravity. Two types of waves are observed: a mode inside the dust volume propagating in the direction of the ion flow and another mode propagating obliquely at the boundary between the dusty plasma and the space charge sheath. The dominance of oblique modes can be described in the frame of a fluid model. It is shown that the results fom the fluid model agree remarkably well with a kinetic electrostatic model of Rosenberg [J. Vac. Sci. Technol. A 14, 631 (1996)]. In the experiment, the instability is quenched by increasing the gas pressure or decreasing the dust density. The critical pressure and dust density are well described by the models

  10. The added value of SPECT-CT for the identification of sentinel lymph nodes in early stage oral cancer

    International Nuclear Information System (INIS)

    Toom, Inne J. den; Bree, Remco de; Schie, Annelies van; Hoekstra, Otto S.; Weert, Stijn van; Karagozoglu, K.H.; Bloemena, Elisabeth

    2017-01-01

    To assess the role of single-photon emission computed tomography with computed tomography (SPECT-CT) for the identification of sentinel lymph nodes (SLNs) in patients with early stage (T1-T2) oral cancer and a clinically negative neck (cN0). In addition to planar lymphoscintigraphy, SPECT-CT was performed in 66 consecutive patients with early stage oral cancer and a clinically negative neck. The addition of SPECT-CT to planar images was retrospectively analyzed for the number of additional SLNs, more precise localization of SLNs, and importance of anatomical information by a team consisting of a nuclear physician, surgeon, and investigator. Identification rate for both imaging modalities combined was 98% (65/66). SPECT-CT identified 15 additional SLNs in 14 patients (22%). In 2/15 (13%) of these additional SLNs, the only metastasis was found, resulting in an upstaging rate of 3% (2/65). In 20% of the patients with at least one positive SLN, the only positive SLN was detected due to the addition of SPECT-CT. SPECT-CT was considered to add important anatomical information in two patients (3%). In 5/65 (8%) of the patients initially scored SLNs on planar lymphoscintigrams were scored as non-SLNs when SPECT-CT was added. There were four false-negative SLN biopsy procedures in this cohort. The addition of SPECT-CT to planar lymphoscintigraphy is recommended for the identification of more (positive) SLNs and better topographical orientation for surgery in sentinel lymph node biopsy for early stage oral cancer. (orig.)

  11. The added value of SPECT-CT for the identification of sentinel lymph nodes in early stage oral cancer

    Energy Technology Data Exchange (ETDEWEB)

    Toom, Inne J. den; Bree, Remco de [VU University Medical Center, Department of Otolaryngology-Head and Neck Surgery, Amsterdam (Netherlands); UMC Utrecht Cancer Center, University Medical Center, Department of Head and Neck Surgical Oncology, PO Box 85500, Utrecht (Netherlands); Schie, Annelies van; Hoekstra, Otto S. [VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Weert, Stijn van [VU University Medical Center, Department of Otolaryngology-Head and Neck Surgery, Amsterdam (Netherlands); Karagozoglu, K.H. [VU University Medical Center/Academic Centre for Dentistry (ACTA) Amsterdam, Department of Oral and Maxillofacial Surgery/Oral Pathology, Amsterdam (Netherlands); Bloemena, Elisabeth [VU University Medical Center/Academic Centre for Dentistry (ACTA) Amsterdam, Department of Oral and Maxillofacial Surgery/Oral Pathology, Amsterdam (Netherlands); VU University Medical Center, Department of Pathology, Amsterdam (Netherlands)

    2017-06-15

    To assess the role of single-photon emission computed tomography with computed tomography (SPECT-CT) for the identification of sentinel lymph nodes (SLNs) in patients with early stage (T1-T2) oral cancer and a clinically negative neck (cN0). In addition to planar lymphoscintigraphy, SPECT-CT was performed in 66 consecutive patients with early stage oral cancer and a clinically negative neck. The addition of SPECT-CT to planar images was retrospectively analyzed for the number of additional SLNs, more precise localization of SLNs, and importance of anatomical information by a team consisting of a nuclear physician, surgeon, and investigator. Identification rate for both imaging modalities combined was 98% (65/66). SPECT-CT identified 15 additional SLNs in 14 patients (22%). In 2/15 (13%) of these additional SLNs, the only metastasis was found, resulting in an upstaging rate of 3% (2/65). In 20% of the patients with at least one positive SLN, the only positive SLN was detected due to the addition of SPECT-CT. SPECT-CT was considered to add important anatomical information in two patients (3%). In 5/65 (8%) of the patients initially scored SLNs on planar lymphoscintigrams were scored as non-SLNs when SPECT-CT was added. There were four false-negative SLN biopsy procedures in this cohort. The addition of SPECT-CT to planar lymphoscintigraphy is recommended for the identification of more (positive) SLNs and better topographical orientation for surgery in sentinel lymph node biopsy for early stage oral cancer. (orig.)

  12. Perfusion lymphoscintigraphy using 99mTc-human serum albumin in patients with treated uterine cancer

    International Nuclear Information System (INIS)

    Kataoka, Masaaki; Hamada, Katsuyuki; Hamamoto, Ken; Takeda, Yasunari; Matsuura, Shumpei; Kawamura, Masashi.

    1990-01-01

    Perfusion lymphoscintigraphy was performed by subcutaneous injection of 7.4 MBq (0.2mCi) 99m Tc-human serum albumin ( 99m Tc-HSA) on 18 patients with uterine cancer treated by operation and/or irradiation. Radioactivity at the injection site was counted for 3 min at 10 min [a] and at 3 hr [b] after injection, and the clearance of 99m Tc-HSA was defined as (1-[b]/[a]) x 100(%) ([a] and [b] were corrected for decay of the isotope). The clearance in 6 legs with lymphedema was significantly more delayed than that in 16 legs without lymphedema in the patients treated with both surgery and irradiation (16.6 ± 7.7% vs 34.9 ± 9.3%: P 99m Tc-HSA is useful for evaluating patients with lymphedema and for differentiating it from edema caused by other mechanisms. (author)

  13. Oblique-view mamography: adequacy for screening. Work in progress

    International Nuclear Information System (INIS)

    Muir, B.B.; Kirkpatrick, A.E.; Roberts, M.M.; Duffy, S.W.

    1984-01-01

    Single oblique-view mammography has been recommended for screening purposes. The authors present data indicating that using the oblique view only can allow 11% of cancers to remain undetected. The smallest and potentially curable cancers are most likely to be overlooked in this way; any possible benefit of screening is thereby reduced. Data are also presented to show that 39% of women may require other views, for reasons not necessarily related to cancer detection. It is therefore recommended that all women have four-view mammography (oblique plus craniocaudal views of each breast) at their first screening visit

  14. Effects of oblique muscle surgery on the rectus muscle pulley

    International Nuclear Information System (INIS)

    Okanobu, Hirotaka; Kono, Reika; Ohtsuki, Hiroshi

    2011-01-01

    The purpose of this study was to determine the position of rectus muscle pulleys in Japanese eyes and to evaluate the effect of oblique muscle surgery on rectus muscle pulleys. Quasi-coronal plane MRI was used to determine area centroids of the 4 rectus muscles. The area centroids of the rectus muscles were transformed to 2-dimensional coordinates to represent pulley positions. The effects of oblique muscle surgery on the rectus muscle pulley positions in the coronal plane were evaluated in 10 subjects with cyclovertical strabismus and, as a control, pulley locations in 7 normal Japanese subjects were calculated. The mean positions of the rectus muscle pulleys in the coronal plane did not significantly differ from previous reports on normal populations, including Caucasians. There were significant positional shifts of the individual horizontal and vertical rectus muscle pulleys in 3 (100%) patients with inferior oblique advancement, but not in eyes with inferior oblique recession and superior oblique tendon advancement surgery. The surgical cyclorotatory effect was significantly correlated with the change in the angle of inclination formed by the line connecting the vertical rectus muscles (p=0.0234), but weakly correlated with that of the horizontal rectus muscles. The most important factor that affects the pulley position is the amount of ocular torsion, not the difference in surgical procedure induced by oblique muscle surgery. (author)

  15. Analyzing RCD30 Oblique Performance in a Production Environment

    Science.gov (United States)

    Soler, M. E.; Kornus, W.; Magariños, A.; Pla, M.

    2016-06-01

    In 2014 the Institut Cartogràfic i Geològic de Catalunya (ICGC) decided to incorporate digital oblique imagery in its portfolio in response to the growing demand for this product. The reason can be attributed to its useful applications in a wide variety of fields and, most recently, to an increasing interest in 3d modeling. The selection phase for a digital oblique camera led to the purchase of the Leica RCD30 Oblique system, an 80MPixel multispectral medium-format camera which consists of one Nadir camera and four oblique viewing cameras acquiring images at an off-Nadir angle of 35º. The system also has a multi-directional motion compensation on-board system to deliver the highest image quality. The emergence of airborne oblique cameras has run in parallel to the inclusion of computer vision algorithms into the traditional photogrammetric workflows. Such algorithms rely on having multiple views of the same area of interest and take advantage of the image redundancy for automatic feature extraction. The multiview capability is highly fostered by the use of oblique systems which capture simultaneously different points of view for each camera shot. Different companies and NMAs have started pilot projects to assess the capabilities of the 3D mesh that can be obtained using correlation techniques. Beyond a software prototyping phase, and taking into account the currently immature state of several components of the oblique imagery workflow, the ICGC has focused on deploying a real production environment with special interest on matching the performance and quality of the existing production lines based on classical Nadir images. This paper introduces different test scenarios and layouts to analyze the impact of different variables on the geometric and radiometric performance. Different variables such as flight altitude, side and forward overlap and ground control point measurements and location have been considered for the evaluation of aerial triangulation and

  16. ANALYZING RCD30 OBLIQUE PERFORMANCE IN A PRODUCTION ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    M. E. Soler

    2016-06-01

    Full Text Available In 2014 the Institut Cartogràfic i Geològic de Catalunya (ICGC decided to incorporate digital oblique imagery in its portfolio in response to the growing demand for this product. The reason can be attributed to its useful applications in a wide variety of fields and, most recently, to an increasing interest in 3d modeling. The selection phase for a digital oblique camera led to the purchase of the Leica RCD30 Oblique system, an 80MPixel multispectral medium-format camera which consists of one Nadir camera and four oblique viewing cameras acquiring images at an off-Nadir angle of 35º. The system also has a multi-directional motion compensation on-board system to deliver the highest image quality. The emergence of airborne oblique cameras has run in parallel to the inclusion of computer vision algorithms into the traditional photogrammetric workflows. Such algorithms rely on having multiple views of the same area of interest and take advantage of the image redundancy for automatic feature extraction. The multiview capability is highly fostered by the use of oblique systems which capture simultaneously different points of view for each camera shot. Different companies and NMAs have started pilot projects to assess the capabilities of the 3D mesh that can be obtained using correlation techniques. Beyond a software prototyping phase, and taking into account the currently immature state of several components of the oblique imagery workflow, the ICGC has focused on deploying a real production environment with special interest on matching the performance and quality of the existing production lines based on classical Nadir images. This paper introduces different test scenarios and layouts to analyze the impact of different variables on the geometric and radiometric performance. Different variables such as flight altitude, side and forward overlap and ground control point measurements and location have been considered for the evaluation of aerial

  17. Theory of the collisional presheath in an oblique magnetic field

    International Nuclear Information System (INIS)

    Riemann, K.

    1994-01-01

    In the limit of a small Debye length (λ D →0), the plasma boundary layer in front of a negative absorbing wall is split up into a collision-free planar space charge sheath and a quasineutral presheath, where the ions are accelerated to ion sound speed (Bohm criterion). Usually the presheath mechanism depends decisively on collisional friction of the ions, on ionization, or on geometric ion current concentration. If the ion dynamics in the presheath is dominated by a magnetic field (nearly) parallel to the wall, an additional effect must be considered to provide an ion transport to the wall. The special cases (a) of an ion transport by field lines intersecting the wall at a finite angle and (b) of an ion transport by collisions result in somewhat contradictory conclusions. To get a coherent picture, a hydrodynamic model of the presheath is investigated accounting for an oblique magnetic field and for collisions. The limiting cases (a) and (b) are discussed, and it is shown that (in plane geometry) the presheath ion acceleration depends always on elementary processes. The main effect of a strong magnetic field is to ''compress'' the collisional presheath into a thin layer with a characteristic extension of the ion gyroradius ρ i

  18. Radionuclide lymphoscintigraphy in the evaluation of peripheral edema

    International Nuclear Information System (INIS)

    Kim, Soon; Zeon, Seok Kil

    2000-01-01

    It has been difficulty to visualize lymphatics in living patients. Conventional or direct lymphography has been the gold standard for delineation of the lymphatic system, but this procedure is invasive, difficulty to perform, and harmful to the lymphatic vascular endothelium. The aim of our study was to determine its severity, and to understand the drainage patterns on patients with peripheral edema by functional lymphatic studies. Tc-99m antimony sulfide colloid 25 MBq with 0.4 ml volume was injected intradermally in the first, second and third web space of the foot or hand in 40 patients with peripheral edema (5 in upper extremity and 35 in lower extremity). Initial flow after injection and whole body images at approximately 30 minutes. 1-4 hours were obtained. In 9/40 cases with peripheral edema normal lymphoscintigram were revealed, primary lymphedema was observed in 5/31 cases. The imaging patterns in primary lymphedema were absent (3 cases) or delayed (2 cases) transport, lymphatic duct dilatation (1), cutoff (1), decrease in size and number of lymph nodes (2). The Common caused of edema in secondry lymphedema (26/31) were carcinoma (13), inflammation (5), post-operation (5), and unknown origin (3). The common imaging findings in carcinoma showed non-visualization of lymph nodes (13), dermal backflow (8), collateral circulation (5), and in inflammation lymphatic obstruction (2), increase in size and number of lymph nodes (2), delayed transport (1), and in post-operation dermal backflow (3), delayed transport (2), decrease in number and size of lymph node (2) Clear images patterns were observed difference between primary lymphedema an secondary lymphedema. Radionuclide lymphoscintigraphy is essentially non-invasive, easy to perform repeatedly, and harmless to the lymphatic vascular endothelium for evaluation of a patient with lymphedema

  19. The Planar Sandwich and Other 1D Planar Heat Flow Test Problems in ExactPack

    Energy Technology Data Exchange (ETDEWEB)

    Singleton, Jr., Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-24

    This report documents the implementation of several related 1D heat flow problems in the verification package ExactPack [1]. In particular, the planar sandwich class defined in Ref. [2], as well as the classes PlanarSandwichHot, PlanarSandwichHalf, and other generalizations of the planar sandwich problem, are defined and documented here. A rather general treatment of 1D heat flow is presented, whose main results have been implemented in the class Rod1D. All planar sandwich classes are derived from the parent class Rod1D.

  20. OBLIQUE MULTI-CAMERA SYSTEMS – ORIENTATION AND DENSE MATCHING ISSUES

    Directory of Open Access Journals (Sweden)

    E. Rupnik

    2014-03-01

    Full Text Available The use of oblique imagery has become a standard for many civil and mapping applications, thanks to the development of airborne digital multi-camera systems, as proposed by many companies (Blomoblique, IGI, Leica, Midas, Pictometry, Vexcel/Microsoft, VisionMap, etc.. The indisputable virtue of oblique photography lies in its simplicity of interpretation and understanding for inexperienced users allowing their use of oblique images in very different applications, such as building detection and reconstruction, building structural damage classification, road land updating and administration services, etc. The paper reports an overview of the actual oblique commercial systems and presents a workflow for the automated orientation and dense matching of large image blocks. Perspectives, potentialities, pitfalls and suggestions for achieving satisfactory results are given. Tests performed on two datasets acquired with two multi-camera systems over urban areas are also reported.

  1. Proposal of limit moment equation applicable to planar/non-planar flaw in wall thinned pipes under bending

    International Nuclear Information System (INIS)

    Tsuji, Masataka; Meshii, Toshiyuki

    2011-01-01

    Highlights: → A limit moment equation applicable to planar/non-planar flaw of 0 ≤ θ ≤ π found in wall thinned straight pipes was proposed. → An idea to rationally classify planar/non-planar flaw in wall thinned pipes was proposed. → The equation based on the experimental observation focused on the fracture mode. - Abstract: In this paper, a limit bending moment equation applicable to all types of planar and non-planar flaws in wall-thinned straight pipes under bending was proposed. A system to rationally classify the planar/non-planar flaws in wall-thinned pipes was suggested based on experimental observations focused on the fracture mode. The results demonstrate the importance of distinguishing between axial and circumferential long flaws in wall-thinned pipes.

  2. HOT STARS WITH HOT JUPITERS HAVE HIGH OBLIQUITIES

    International Nuclear Information System (INIS)

    Winn, Joshua N.; Albrecht, Simon; Fabrycky, Daniel; Johnson, John Asher

    2010-01-01

    We show that stars with transiting planets for which the stellar obliquity is large are preferentially hot (T eff > 6250 K). This could explain why small obliquities were observed in the earliest measurements, which focused on relatively cool stars drawn from Doppler surveys, as opposed to hotter stars that emerged more recently from transit surveys. The observed trend could be due to differences in planet formation and migration around stars of varying mass. Alternatively, we speculate that hot-Jupiter systems begin with a wide range of obliquities, but the photospheres of cool stars realign with the orbits due to tidal dissipation in their convective zones, while hot stars cannot realign because of their thinner convective zones. This in turn would suggest that hot Jupiters originate from few-body gravitational dynamics and that disk migration plays at most a supporting role.

  3. Routine oblique radiography of the pediatric lumbar spine: is it necessary. [Oblique radiography entails more than double the gonadal radiation dose of frontal-lateral projections

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, F.F.; Kishore, P.R.S.; Cunningham, M.E.

    1978-08-01

    A series of 86 pediatric lumbar spine abnormalities was evaluated to determine the diagnostic benefit of radiography in oblique projection as compared to frontal-lateral projections alone. In only four patients was an abnormality apparent on the oblique view which had not already been demonstrated by the frontal-lateral series; each of these represented an isolated spondylolysis. Because the diagnostic yield was low at a patient cost of more than double the gonadal radiation dose, it is recommended that oblique views be eliminated in the routine radiography of the pediatric lumbar spine.

  4. ACCURACY OF MEASUREMENTS IN OBLIQUE AERIAL IMAGES FOR URBAN ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    W. Ostrowski

    2016-10-01

    Full Text Available Oblique aerial images have been a source of data for urban areas for several years. However, the accuracy of measurements in oblique images during this time has been limited to a single meter due to the use of direct -georeferencing technology and the underlying digital elevation model. Therefore, oblique images have been used mostly for visualization purposes. This situation changed in recent years as new methods, which allowed for a higher accuracy of exterior orientation, were developed. Current developments include the process of determining exterior orientation and the previous but still crucial process of tie point extraction. Progress in this area was shown in the ISPRS/EUROSDR Benchmark on Multi-Platform Photogrammetry and is also noticeable in the growing interest in the use of this kind of imagery. The higher level of accuracy in the orientation of oblique aerial images that has become possible in the last few years should result in a higher level of accuracy in the measurements of these types of images. The main goal of this research was to set and empirically verify the accuracy of measurements in oblique aerial images. The research focused on photogrammetric measurements composed of many images, which use a high overlap within an oblique dataset and different view angles. During the experiments, two series of images of urban areas were used. Both were captured using five DigiCam cameras in a Maltese cross configuration. The tilt angles of the oblique cameras were 45 degrees, and the position of the cameras during flight used a high grade GPS/INS navigation system. The orientation of the images was set using the Pix4D Mapper Pro software with both measurements of the in-flight camera position and the ground control points (measured with GPS RTK technology. To control the accuracy, check points were used (which were also measured with GPS RTK technology. As reference data for the whole study, an area of the city-based map was used

  5. Truncation correction for oblique filtering lines

    International Nuclear Information System (INIS)

    Hoppe, Stefan; Hornegger, Joachim; Lauritsch, Guenter; Dennerlein, Frank; Noo, Frederic

    2008-01-01

    State-of-the-art filtered backprojection (FBP) algorithms often define the filtering operation to be performed along oblique filtering lines in the detector. A limited scan field of view leads to the truncation of those filtering lines, which causes artifacts in the final reconstructed volume. In contrast to the case where filtering is performed solely along the detector rows, no methods are available for the case of oblique filtering lines. In this work, the authors present two novel truncation correction methods which effectively handle data truncation in this case. Method 1 (basic approach) handles data truncation in two successive preprocessing steps by applying a hybrid data extrapolation method, which is a combination of a water cylinder extrapolation and a Gaussian extrapolation. It is independent of any specific reconstruction algorithm. Method 2 (kink approach) uses similar concepts for data extrapolation as the basic approach but needs to be integrated into the reconstruction algorithm. Experiments are presented from simulated data of the FORBILD head phantom, acquired along a partial-circle-plus-arc trajectory. The theoretically exact M-line algorithm is used for reconstruction. Although the discussion is focused on theoretically exact algorithms, the proposed truncation correction methods can be applied to any FBP algorithm that exposes oblique filtering lines.

  6. Development of a dextran kit for labelling with 99mTc and its evaluation for lymphoscintigraphy

    International Nuclear Information System (INIS)

    Dass, R.S.; Singh, A.K.; Chauhan, U.P.S.

    1993-01-01

    A cold dextran (molecular weight 60,000-90,000) kit has been developed by a modified procedure to produce instant preparation of 99m Tc-dextran suitable for lymphoscintigraphy. The preparation was subjected to various quality control measures. Effect of pH and amount of stannous chloride as a reducing agent on the labelling efficiency using ITLC were studied. The labelled complex was separated from both the reduced pertechnetate and pertechnetate and quantified. In a series of experiments, hydrolysed/reduced 99m Tc was found to be less than 3.0%, whereas pertechnetate was approx. 1.0%. Biokinetics of the agent in mice and blood clearance and rate of disappearance from the site of intradermal injection of the agent in rabbits were studied. The tagged agent for imaging of the lymphatic system activated by administering Freund's complete adjuvant (FCA)/E. coli in rabbits exhibited its suitability for lymposcintigraphy. (Author)

  7. Variability in DMSA reporting following urinary tract infection in children: pinhole, planar, and pinhole with planar

    International Nuclear Information System (INIS)

    Rossleigh, M.A.; Christian, C.L.; Craig, J.C.; Howman-Giles, R.B.; Grunewald, S.

    2004-01-01

    Purpose: To determine whether the provision of DMSA images obtained by pinhole collimation reduces inter-observer variability of reporting compared with planar DMSA images alone. Methods: One hundred consecutive DMSA images were independently interpreted three times (pinhole alone, planar alone, pinhole and planar) by four participating nuclear medicine specialists from different departments and in random order. The presence or absence of renal parenchymal abnormality was classified using the modified four level grading system of Goldraich with mean values for the 6 comparisons reported. Results: The proportion of DMSA images interpreted as abnormal was 31% for planar, 34% for pinhole and 33% for planar with pinhole. Agreement was 89% for planar alone, 89% for pinhole alone and 90% for planar with pinhole, with kappa values 0.74, 0.75 and 0.80 respectively for the normal-abnormal scan classification of individual children. These results did not vary appreciably whether interpretation of patients, kidneys or kidney zones was compared. Reasons for disagreement in reporting included different interpretations of 'abnormalities' as normal anatomical variations (splenic impression, fetal lobulation, duplex collecting systems, column of Bertin) or true parenchymal abnormalities, different adjustments in thresholds for reporting abnormality when images were technically suboptimal, different weighting given to pinhole and planar images when both were provided, and error. Conclusion: Four experienced nuclear medicine physicians showed substantial agreement in the interpretation of planar alone, pinhole alone and planar with pinhole DMSA images, but the provision of both sets of images, planar and pinhole, did not reduce variability. (authors)

  8. Which oblique plane is more helpful in diagnosing an anterior cruciate ligament tear?

    International Nuclear Information System (INIS)

    Kwon, J.W.; Yoon, Y.C.; Kim, Y.N.; Ahn, J.H.; Choe, B.K.

    2009-01-01

    Aim: To evaluate the diagnostic role of additional oblique coronal and oblique sagittal magnetic resonance imaging (MRI) for an anterior cruciate ligament (ACL) tear. Materials and methods: A total of 101 patients who had undergone preoperative knee MRI examinations with orthogonal and two sets of oblique images were enrolled in the study. Two radiologists evaluated the MRI images by the use of four methods: orthogonal images only (method A); orthogonal and additional oblique coronal images (method B); orthogonal and oblique sagittal images (method C); and orthogonal images with oblique coronal and sagittal images (method D). The status of the ACL (normal or tear) was determined by consensus. The sensitivity, specificity, and accuracy for an ACL tear with the use of each method were calculated in comparison with arthroscopy as the reference standard, and values were statistically analysed using the McNemar test. The diagnostic accuracies were compared using receiver operating characteristic (ROC) analysis. Results: Arthroscopy identified 10 partial ACL tears and 30 complete ACL tears. The specificities and accuracies for methods B, C, and D were significantly higher than the specificities and accuracies for method A (p 0.05). Conclusions: Additional oblique imaging for an ACL tear improved the specificity. Either of the oblique imaging methods is sufficient, and no further improvement in the diagnostic efficacy was achieved by simultaneous use

  9. Radiation transport modelling for the interpretation of oblique ECE measurements

    Directory of Open Access Journals (Sweden)

    Denk Severin S.

    2017-01-01

    Since radiation transport modelling is required for the interpretation of oblique ECE diagnostics we present in this paper an extended forward model that supports oblique lines of sight. To account for the refraction of the line of sight, ray tracing in the cold plasma approximation was added to the model. Furthermore, an absorption coefficient valid for arbitrary propagation was implemented. Using the revised model it is shown that for the oblique ECE Imaging diagnostic at ASDEX Upgrade there can be a significant difference between the cold resonance position and the point from which most of the observed radiation originates.

  10. A Quick and Affine Invariance Matching Method for Oblique Images

    Directory of Open Access Journals (Sweden)

    XIAO Xiongwu

    2015-04-01

    Full Text Available This paper proposed a quick, affine invariance matching method for oblique images. It calculated the initial affine matrix by making full use of the two estimated camera axis orientation parameters of an oblique image, then recovered the oblique image to a rectified image by doing the inverse affine transform, and left over by the SIFT method. We used the nearest neighbor distance ratio(NNDR, normalized cross correlation(NCC measure constraints and consistency check to get the coarse matches, then used RANSAC method to calculate the fundamental matrix and the homography matrix. And we got the matches that they were interior points when calculating the homography matrix, then calculated the average value of the matches' principal direction differences. During the matching process, we got the initial matching features by the nearest neighbor(NN matching strategy, then used the epipolar constrains, homography constrains, NCC measure constrains and consistency check of the initial matches' principal direction differences with the calculated average value of the interior matches' principal direction differences to eliminate false matches. Experiments conducted on three pairs of typical oblique images demonstrate that our method takes about the same time as SIFT to match a pair of oblique images with a plenty of corresponding points distributed evenly and an extremely low mismatching rate.

  11. Multimodal Imaging in Klippel-Trénaunay-Weber Syndrome: Clinical Photography, Computed Tomoangiography, Infrared Thermography, and 99mTc-Phytate Lymphoscintigraphy.

    Science.gov (United States)

    Kim, Su Wan; Song, Heesung

    2017-12-01

    We report the case of a 19-year-old man who presented with a 12-year history of progressive fatigue, feeling hot, excessive sweating, and numbness in the left arm. He had undergone multimodal imaging and was diagnosed as having Klippel-Trénaunay-Weber syndrome (KTWS). This is a rare congenital disease, defined by combinations of nevus flammeus, venous and lymphatic malformation, and hypertrophy of the affected limbs. Lower extremities are affected mostly. Conventional modalities for evaluating KTWS are ultrasonography, CT, MRI, lymphoscintigraphy, and angiography. There are few reports on multimodal imaging of upper extremities of KTWS patients, and this is the first report of an infrared thermography in KTWS.

  12. Optically sectioned imaging by oblique plane microscopy

    Science.gov (United States)

    Kumar, Sunil; Lin, Ziduo; Lyon, Alex R.; MacLeod, Ken T.; Dunsby, Chris

    2011-03-01

    Oblique Plane Microscopy (OPM) is a light sheet microscopy technique that combines oblique illumination with correction optics that tilt the focal plane of the collection system. OPM can be used to image conventionally mounted specimens on coverslips or tissue culture dishes and has low out-of-plane photobleaching and phototoxicity. No moving parts are required to achieve an optically sectioned image and so high speed optically sectioned imaging is possible. The first OPM results obtained using a high NA water immersion lens on a commercially available inverted microscope frame are presented, together with a measurement of the achievable optical resolution.

  13. Amplification of obliquity forcing through mean annual and seasonal atmospheric feedbacks

    Directory of Open Access Journals (Sweden)

    S.-Y. Lee

    2008-10-01

    Full Text Available Pleistocene benthic δ18O records exhibit strong spectral power at ~41 kyr, indicating that global ice volume has been modulated by Earth's axial tilt. This feature, and weak spectral power in the precessional band, has been attributed to the influence of obliquity on mean annual and seasonal insolation gradients at high latitudes. In this study, we use a coupled ocean-atmosphere general circulation model to quantify changes in continental snowfall associated with mean annual and seasonal insolation forcing due to a change in obliquity. Our model results indicate that insolation changes associated with a decrease in obliquity amplify continental snowfall in three ways: (1 Local reductions in air temperature enhance precipitation as snowfall. (2 An intensification of the winter meridional insolation gradient strengthens zonal circulation (e.g. the Aleutian low, promoting greater vapor transport from ocean to land and snow precipitation. (3 An increase in the summer meridional insolation gradient enhances summer eddy activity, increasing vapor transport to high-latitude regions. In our experiments, a decrease in obliquity leads to an annual snowfall increase of 25.0 cm; just over one-half of this response (14.1 cm is attributed to seasonal changes in insolation. Our results indicate that the role of insolation gradients is important in amplifying the relatively weak insolation forcing due to a change in obliquity. Nonetheless, the total snowfall response to obliquity is similar to that due to a shift in Earth's precession, suggesting that obliquity forcing alone can not account for the spectral characteristics of the ice-volume record.

  14. Ionospheric Oblique Incidence Soundings by Satellites

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The oblique incidence sweep-frequency ionospheric sounding technique uses the same principle of operation as the vertical incidence sounder. The primary difference...

  15. How to draw a planarization

    NARCIS (Netherlands)

    Bläsius, T.; Radermacher, M.; Rutter, I.; Steffen, B.; Baier, C.; van den Brand, M.; Eder, J.; Hinchey, M.; Margaria, T.

    2017-01-01

    We study the problem of computing straight-line drawings of non-planar graphs with few crossings. We assume that a crossing-minimization algorithm is applied first, yielding a planarization, i.e., a planar graph with a dummy vertex for each crossing, that fixes the topology of the resulting drawing.

  16. Cosmic-ray shock acceleration in oblique MHD shocks

    Science.gov (United States)

    Webb, G. M.; Drury, L. OC.; Volk, H. J.

    1986-01-01

    A one-dimensional, steady-state hydrodynamical model of cosmic-ray acceleration at oblique MHD shocks is presented. Upstream of the shock the incoming thermal plasma is subject to the adverse pressure gradient of the accelerated particles, the J x B force, as well as the thermal gas pressure gradient. The efficiency of the acceleration of cosmic-rays at the shock as a function of the upstream magnetic field obliquity and upstream plasma beta is investigated. Astrophysical applications of the results are briefly discussed.

  17. Constraints on the near-Earth asteroid obliquity distribution from the Yarkovsky effect

    Science.gov (United States)

    Tardioli, C.; Farnocchia, D.; Rozitis, B.; Cotto-Figueroa, D.; Chesley, S. R.; Statler, T. S.; Vasile, M.

    2017-12-01

    Aims: From light curve and radar data we know the spin axis of only 43 near-Earth asteroids. In this paper we attempt to constrain the spin axis obliquity distribution of near-Earth asteroids by leveraging the Yarkovsky effect and its dependence on an asteroid's obliquity. Methods: By modeling the physical parameters driving the Yarkovsky effect, we solve an inverse problem where we test different simple parametric obliquity distributions. Each distribution results in a predicted Yarkovsky effect distribution that we compare with a χ2 test to a dataset of 125 Yarkovsky estimates. Results: We find different obliquity distributions that are statistically satisfactory. In particular, among the considered models, the best-fit solution is a quadratic function, which only depends on two parameters, favors extreme obliquities consistent with the expected outcomes from the YORP effect, has a 2:1 ratio between retrograde and direct rotators, which is in agreement with theoretical predictions, and is statistically consistent with the distribution of known spin axes of near-Earth asteroids.

  18. Design of special planar linkages

    CERN Document Server

    Zhao, Jing-Shan; Ma, Ning; Chu, Fulei

    2013-01-01

    Planar linkages play a very important role in mechanical engineering. As the simplest closed chain mechanisms, planar four-bar linkages are widely used in mechanical engineering, civil engineering and aerospace engineering.Design of Special Planar Linkages proposes a uniform design theory for planar four-bar linkages. The merit of the method proposed in this book is that it allows engineers to directly obtain accurate results when there are such solutions for the specified n precise positions; otherwise, the best approximate solutions will be found. This book discusses the kinematics and reach

  19. Research On The Measure Method Of Oblique Pinhole Parameters

    Directory of Open Access Journals (Sweden)

    Ma Yu-Zhen

    2016-01-01

    Full Text Available There are many special advantages in measuring the diameter of blind and deep holes with a capacitive probe, there are still some challenges for the measurement of a oblique pinhole parameters because the measuring device is inconvenient to stretch into the oblique pinhole exactly. A five-dimensional measurement system was adopted in the paper which included a capacitive sensor probe and a three-coordinate measuring machine to accomplish the measurement for oblique pinholes. With the help of the three-dimensional coordinates measured from the pinhole axis, we put forward a comprehensive method of combining the projection method and the least squares method together for fitting spatial straight line to obtain the optimal equation of the spacial axis. Finally, a reliable and entire measurement system was set up.

  20. Inferior oblique muscle paresis as a sign of myasthenia gravis.

    Science.gov (United States)

    Almog, Yehoshua; Ben-David, Merav; Nemet, Arie Y

    2016-03-01

    Myasthenia gravis may affect any of the six extra-ocular muscles, masquerading as any type of ocular motor pathology. The frequency of involvement of each muscle is not well established in the medical literature. This study was designed to determine whether a specific muscle or combination of muscles tends to be predominantly affected. This retrospective review included 30 patients with a clinical diagnosis of myasthenia gravis who had extra-ocular muscle involvement with diplopia at presentation. The diagnosis was confirmed by at least one of the following tests: Tensilon test, acetylcholine receptor antibodies, thymoma on chest CT scan, or suggestive electromyography. Frequency of involvement of each muscle in this cohort was inferior oblique 19 (63.3%), lateral rectus nine (30%), superior rectus four (13.3%), inferior rectus six (20%), medial rectus four (13.3%), and superior oblique three (10%). The inferior oblique was involved more often than any other muscle (pmyasthenia gravis can be difficult, because the disease may mimic every pupil-sparing pattern of ocular misalignment. In addition diplopia caused by paresis of the inferior oblique muscle is rarely encountered (other than as a part of oculomotor nerve palsy). Hence, when a patient presents with vertical diplopia resulting from an isolated inferior oblique palsy, myasthenic etiology should be highly suspected. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Axial oblique MR imaging of the intrinsic ligaments of the wrist: initial experience

    International Nuclear Information System (INIS)

    Robinson, G.; Chung, T.; Finlay, K.; Friedman, L.

    2006-01-01

    To evaluate two separate MR sequences acquired in the axial oblique plane, parallel to the long axis of the scapholunate (SL) and lunotriquetral (LT) ligaments, to determine whether the addition of these sequences to the standard MR wrist examination improves visualization of the intrinsic ligaments, and the evaluation of their integrity. To our knowledge, this plane has not been described in the literature previously. In total we evaluated 26 patients with chronic wrist pain or instability, referred for MR imaging following assessment by an orthopedic surgeon or physiatrist. All patients underwent initial conventional tri-compartment wrist arthrography, which served as the reference standard. This was immediately followed by MR arthrography, in the standard coronal and true axial planes, as well as in the axial oblique plane. The SL and LT ligaments were initially assessed for the presence or absence of tear, using the standard coronal and true axial sequences, and subsequently re-evaluated with the addition of the axial oblique planes. A total of ten intrinsic ligament tears were identified with conventional arthrography: six SL and four LT tears. Five of the six SL tears were identified on the standard sequences. All six were diagnosed with the addition of the oblique sequences. There were three false-positive SL tears identified using standard MR imaging, and two false-positives with the addition of the oblique sequences. No LT tear was identified on standard sequences, whereas all four were confidently seen with the addition of oblique images. No false-positives of the LT ligament were recorded with either standard or axial oblique sequences. The study suggests that the addition of axial oblique MR sequences helps identify tears to the intrinsic ligaments of the wrist, particularly the LT ligament. In addition, the axial oblique images assist in localization of the tear. (orig.)

  2. Routine oblique radiography of the pediatric lumbar spine: is it necessary

    International Nuclear Information System (INIS)

    Roberts, F.F.; Kishore, P.R.S.; Cunningham, M.E.

    1978-01-01

    A series of 86 pediatric lumbar spine abnormalities was evaluated to determine the diagnostic benefit of radiography in oblique projection as compared to frontal-lateral projections alone. In only four patients was an abnormality apparent on the oblique view which had not already been demonstrated by the frontal-lateral series; each of these represented an isolated spondylolysis. Because the diagnostic yield was low at a patient cost of more than double the gonadal radiation dose, it is recommended that oblique views be eliminated in the routine radiography of the pediatric lumbar spine

  3. Staging N0 Oral Cancer: Lymphoscintigraphy and Conventional Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, J.B.; Soerensen, J.A.; Grupe, P.; Karstoft, J.; Krogdahl, A. [Odense Univ. Hospital (Denmark). Depts. of Plastic and Reconstructive Surgery, Nuclear Medicine, Radiology, and Pathology

    2005-08-01

    PURPOSE: To compare sentinel lymph node biopsy, magnetic resonance imaging (MRI), Doppler ultrasonography, and palpation as staging tools in patients with T1/T2 N0 cancer of the oral cavity. MATERIAL AND METHODS: Forty consecutive patients were enrolled (17 F and 23 M, aged 32-90 years), 24 T1 and 16 T2 cN0 squamous cell carcinoma of the oral cavity. Palpation was carried out by two observers prior to inclusion. MRI, gray-scale and Doppler ultrasonography were performed. Lymphoscintigraphies were done after peritumoral injections of 99mTc labelled rheniumsulphide nanocolloid, followed by sentinel lymph node biopsy guided by a gamma probe and Patent Blue. Palpation, Doppler ultrasonography, MRI, and sentinel lymph node biopsy were compared to a combination of histopathology and follow-up. Diagnostic testing was performed using the x2 test. RESULTS: Histopathological examination revealed metastatic spread to the neck in 14 of 40 patients. One patient had bilateral neck disease. Sentinel lymph node biopsy and ultrasonography were performed in 80 neck sides of 40 patients and MRI in 70 neck sides (5 patients were claustrophobic). SN revealed suspicious lymph nodes in 12 necks, ultrasonography in 23 necks, and MRI in 9 necks. The positive predictive value of sentinel lymph node biopsy was 100%, ultrasonography 57%, and MRI 56%. The respective negative predictive values were 96%, 96%, and 85%. The sensitivity of sentinel lymph node biopsy 80% was comparable to ultrasonography 87%, but the sensitivity of MRI 36% was low. The specificities were 100%, 85%, and 93%, respectively. By combined sentinel lymph node biopsy and ultrasonography the overall sensitivity could have been 100%. CONCLUSION: Sentinel lymph node biopsy improved staging of patients with small N0 oral cancers. Combined sentinel lymph node biopsy and Doppler ultrasonography may further improve staging. MRI and simple palpation results were poor.

  4. Oblique decision trees using embedded support vector machines in classifier ensembles

    NARCIS (Netherlands)

    Menkovski, V.; Christou, I.; Efremidis, S.

    2008-01-01

    Classifier ensembles have emerged in recent years as a promising research area for boosting pattern recognition systems' performance. We present a new base classifier that utilizes oblique decision tree technology based on support vector machines for the construction of oblique (non-axis parallel)

  5. Surgical Results in Unilateral Superior Oblique Muscle Palsy

    Directory of Open Access Journals (Sweden)

    Aylin Tenlik

    2014-08-01

    Full Text Available Objectives: To evaluate the surgical treatments and results of the patients with superior oblique muscle palsy (SOMP. Materials and Methods: Clinical charts of the patients with unilateral SOMP who were operated in our clinic between 1999 and 2009 were evaluated retrospectively. Patients’ demographics, preoperative signs, surgical procedure, complications, and final results were recorded. Results: Thirty-seven patients were included in the study, [21 (59% male, 15 (41% female]. The mean age was 20.6 years at the time of operation. The mean time interval between diagnosis and operation was 7.3 years. Postoperative follow-up period was 2.04 (ranging 1-10 years. Diplopia was determined in seven (18.9% patients, and abnormal head position in 36 (97.3% patients. Only inferior oblique tenotomy with distal muscle resection was performed in 25 patients. In addition, five patients had recession of the contralateral inferior rectus muscle and two patients had recession of the ipsilateral superior rectus muscle additional to inferior oblique tenotomy. Abnormal head position was completely improved in all of the patients postoperatively. The preoperative average score of the inferior oblique muscle (IOM overaction was +3.3±0.8, and postoperative overaction was found in only two patients (+1.5. There was statistically significant difference between the two periods (p<0.001. The average score of the superior oblique muscle hypofunction was -2.18 preoperatively, and in only three patients, the score was found -1.0 postoperatively. Difference between the two periods was statistically significant (p<0.001. While the preoperative average vertical deviation was 22 PD in primary position, none of the patients had hyperdeviation postoperatively. Diplopia was resolved in all seven affected patients postoperatively. Contralateral IOM hyperfunction was the most common complication (13.5%. Adherence syndrome was seen in none of the patients. Conclusion: It was found

  6. Independent sources of anisotropy in visual orientation representation: a visual and a cognitive oblique effect.

    Science.gov (United States)

    Balikou, Panagiota; Gourtzelidis, Pavlos; Mantas, Asimakis; Moutoussis, Konstantinos; Evdokimidis, Ioannis; Smyrnis, Nikolaos

    2015-11-01

    The representation of visual orientation is more accurate for cardinal orientations compared to oblique, and this anisotropy has been hypothesized to reflect a low-level visual process (visual, "class 1" oblique effect). The reproduction of directional and orientation information also leads to a mean error away from cardinal orientations or directions. This anisotropy has been hypothesized to reflect a high-level cognitive process of space categorization (cognitive, "class 2," oblique effect). This space categorization process would be more prominent when the visual representation of orientation degrades such as in the case of working memory with increasing cognitive load, leading to increasing magnitude of the "class 2" oblique effect, while the "class 1" oblique effect would remain unchanged. Two experiments were performed in which an array of orientation stimuli (1-4 items) was presented and then subjects had to realign a probe stimulus within the previously presented array. In the first experiment, the delay between stimulus presentation and probe varied, while in the second experiment, the stimulus presentation time varied. The variable error was larger for oblique compared to cardinal orientations in both experiments reproducing the visual "class 1" oblique effect. The mean error also reproduced the tendency away from cardinal and toward the oblique orientations in both experiments (cognitive "class 2" oblique effect). The accuracy or the reproduced orientation degraded (increasing variable error) and the cognitive "class 2" oblique effect increased with increasing memory load (number of items) in both experiments and presentation time in the second experiment. In contrast, the visual "class 1" oblique effect was not significantly modulated by any one of these experimental factors. These results confirmed the theoretical predictions for the two anisotropies in visual orientation reproduction and provided support for models proposing the categorization of

  7. Simple Way of Generating Oblique Impact

    Czech Academy of Sciences Publication Activity Database

    Trnka, Jan; Dvořáková, Pavla; Veselý, Eduard

    2007-01-01

    Roč. 31, č. 2 (2007), s. 28-32 ISSN 0732-8818 Institutional research plan: CEZ:AV0Z20760514 Keywords : oblique impact * exploding wire * holography Subject RIV: JR - Other Machinery Impact factor: 0.400, year: 2007

  8. Response of PMHS to high- and low-speed oblique and lateral pneumatic ram impacts.

    Science.gov (United States)

    Rhule, Heather; Suntay, Brian; Herriott, Rodney; Amenson, Tara; Stricklin, Jim; Bolte, John H

    2011-11-01

    In ISO Technical Report 9790 (1999) normalized lateral and oblique thoracic force-time responses of PMHS subjected to blunt pendulum impacts at 4.3 m/s were deemed sufficiently similar to be grouped together in a single biomechanical response corridor. Shaw et al. (2006) presented results of paired oblique and lateral thoracic pneumatic ram impact tests to opposite sides of seven PMHS at sub-injurious speed (2.5 m/s). Normalized responses showed that oblique impacts resulted in more deflection and less force, whereas lateral impacts resulted in less deflection and more force. This study presents results of oblique and lateral thoracic impacts to PMHS at higher speeds (4.5 and 5.5 m/s) to assess whether lateral relative to oblique responses are different as observed by Shaw et al. or similar as observed by ISO. Twelve PMHS were impacted by a 23 kg pneumatic ram with a 152.4 mmx304.8 mm rectangular face plate at the level of the xyphoid process in either the pure lateral or 30° anterior-to-lateral oblique direction. Because these tests were potentially injurious, only one test per subject was conducted. Normalized responses demonstrate similar characteristics for both lateral and oblique impacts, indicating that it may be reasonable to combine lateral and oblique responses together at these higher speeds to define characteristic PMHS response as was done by ISO. The small number of tests conducted indicates that less chest compression may be required to obtain serious thoracic injury in oblique impacts as compared to lateral impacts at speeds of 4.5 or 5.5 m/s.

  9. Non-planar ABJ theory and parity

    International Nuclear Information System (INIS)

    Caputa, Pawel; Kristjansen, Charlotte; Zoubos, Konstantinos

    2009-01-01

    While the ABJ Chern-Simons-matter theory and its string theory dual manifestly lack parity invariance, no sign of parity violation has so far been observed on the weak coupling spin chain side. In particular, the planar two-loop dilatation generator of ABJ theory is parity invariant. In this Letter we derive the non-planar part of the two-loop dilatation generator of ABJ theory in its SU(2)xSU(2) sub-sector. Applying the dilatation generator to short operators, we explicitly demonstrate that, for operators carrying excitations on both spin chains, the non-planar part breaks parity invariance. For operators with only one type of excitation, however, parity remains conserved at the non-planar level. We furthermore observe that, as for ABJM theory, the degeneracy between planar parity pairs is lifted when non-planar corrections are taken into account.

  10. Non-planar ABJ Theory and Parity

    DEFF Research Database (Denmark)

    Caputa, Pawel; Kristjansen, Charlotte; Zoubos, Konstantinos

    2009-01-01

    we derive the non-planar part of the two-loop dilatation generator of ABJ theory in its SU(2)xSU(2) sub-sector. Applying the dilatation generator to short operators, we explicitly demonstrate that, for operators carrying excitations on both spin chains, the non-planar part breaks parity invariance......While the ABJ Chern-Simons-matter theory and its string theory dual manifestly lack parity invariance, no sign of parity violation has so far been observed on the weak coupling spin chain side. In particular, the planar two-loop dilatation generator of ABJ theory is parity invariant. In this letter....... For operators with only one type of excitation, however, parity remains conserved at the non-planar level. We furthermore observe that, as for ABJM theory, the degeneracy between planar parity pairs is lifted when non-planar corrections are taken into account....

  11. Characterization of Oblique Dual Frame Pairs

    DEFF Research Database (Denmark)

    Christensen, Ole; Eldar, Yonina

    2006-01-01

    Given a frame for a subspace W of a Hilbert space H, we consider all possible families of oblique dual frame vectors on an appropriately chosen subspace V. In place of the standard description, which involves computing the pseudoinverse of the frame operator, we develop an alternative characteriz...... for the case of shift-invariant spaces with a single generator. The theory is also adapted to the standard frame setting in which the original and dual frames are defined on the same space. Copyright (C) 2006 Hindawi Publishing Corporation. All rights reserved.......Given a frame for a subspace W of a Hilbert space H, we consider all possible families of oblique dual frame vectors on an appropriately chosen subspace V. In place of the standard description, which involves computing the pseudoinverse of the frame operator, we develop an alternative...

  12. Evaluation of macular thickness change after inferior oblique muscle recession surgery

    Directory of Open Access Journals (Sweden)

    Ece Turan-Vural

    2014-01-01

    Full Text Available Purpose: This study aimed to evaluate the changes in macular thickness following inferior oblique muscle recession surgery. Materials and Methods: Thirty-eight eyes from 21 patients undergoing ocular muscle surgery were included. Patients were grouped into three groups based on the type of surgical intervention: Group I (n = 12, inferior oblique recession surgery alone; Group II (n = 12, inferior oblique plus horizontal muscle surgery; Group III (n = 14, horizontal muscle surgery alone. Each eye was scanned using the optical coherence tomography (OCT device preoperatively and on the first postoperative day to measure macular thickness. Results: Following surgery, a significant increase in foveal thickness occurred in Group I (P < 0.05 and Group II (P < 0.01. In addition, a statistically significant difference was observed between the groups with regard to the increase in foveal thickness (P = 0.016, with significantly lower changes in Group III. Conclusion: Our findings suggested that inferior oblique muscle recession surgery is associated with an increase in macular thickness.

  13. The role of lymphoscintigraphy, sentinel mode biopsy and positron emission tomography in the staging of the neck in early oral squamous cell carcinoma

    Science.gov (United States)

    Hyde, Nicholas Charles

    This thesis explores the limitations of current imaging modalities in the evaluation of the clinically node negative (N0) neck in early oral squamous cell carcinoma and evaluates the utility of two new interventions. It will become evident that the use of clinical parameters and conventional imaging to detect clinically occult cervical lymph node metastases is an imprecise science. The presence of metastases in the neck is the single most important determinant of survival. Hitherto the lack of timely intervention in this regard may have been contributory in amplifying their effect upon survival. There is an obvious requirement for a more accurate technique to stage the neck in this patient group. Therefore the application of lymphoscintigraphy in combination with sentinel node biopsy (SNB), and positron emission tomography (PET) have been investigated. It appears that PET, whilst having a number of useful roles in the generic head and neck oncology patient, has little to contribute in the diagnosis of occult neck disease. In contra-distinction lymphoscintigraphy and SNB are not only feasible in the diagnosis of occult metastases, but also enhance our knowledge of lymphatic drainage from the oral cavity. This has, in some circumstances, led to the modification of initially prescribed treatment plans. Such is the current pace of technological advance that over the course of this research an entirely new imaging modality has emerged - PET/CT. Whilst it has not been possible to apply this retrospectively to the original patient population early experience of this novel technique in head and neck malignancy is explored and reported. The results of these initial applications are encouraging.

  14. Oblique reconstructions in tomosynthesis. II. Super-resolution

    International Nuclear Information System (INIS)

    Acciavatti, Raymond J.; Maidment, Andrew D. A.

    2013-01-01

    Purpose: In tomosynthesis, super-resolution has been demonstrated using reconstruction planes parallel to the detector. Super-resolution allows for subpixel resolution relative to the detector. The purpose of this work is to develop an analytical model that generalizes super-resolution to oblique reconstruction planes.Methods: In a digital tomosynthesis system, a sinusoidal test object is modeled along oblique angles (i.e., “pitches”) relative to the plane of the detector in a 3D divergent-beam acquisition geometry. To investigate the potential for super-resolution, the input frequency is specified to be greater than the alias frequency of the detector. Reconstructions are evaluated in an oblique plane along the extent of the object using simple backprojection (SBP) and filtered backprojection (FBP). By comparing the amplitude of the reconstruction against the attenuation coefficient of the object at various frequencies, the modulation transfer function (MTF) is calculated to determine whether modulation is within detectable limits for super-resolution. For experimental validation of super-resolution, a goniometry stand was used to orient a bar pattern phantom along various pitches relative to the breast support in a commercial digital breast tomosynthesis system.Results: Using theoretical modeling, it is shown that a single projection image cannot resolve a sine input whose frequency exceeds the detector alias frequency. The high frequency input is correctly visualized in SBP or FBP reconstruction using a slice along the pitch of the object. The Fourier transform of this reconstructed slice is maximized at the input frequency as proof that the object is resolved. Consistent with the theoretical results, experimental images of a bar pattern phantom showed super-resolution in oblique reconstructions. At various pitches, the highest frequency with detectable modulation was determined by visual inspection of the bar patterns. The dependency of the highest

  15. Oblique reconstructions in tomosynthesis. II. Super-resolution

    Science.gov (United States)

    Acciavatti, Raymond J.; Maidment, Andrew D. A.

    2013-01-01

    Purpose: In tomosynthesis, super-resolution has been demonstrated using reconstruction planes parallel to the detector. Super-resolution allows for subpixel resolution relative to the detector. The purpose of this work is to develop an analytical model that generalizes super-resolution to oblique reconstruction planes. Methods: In a digital tomosynthesis system, a sinusoidal test object is modeled along oblique angles (i.e., “pitches”) relative to the plane of the detector in a 3D divergent-beam acquisition geometry. To investigate the potential for super-resolution, the input frequency is specified to be greater than the alias frequency of the detector. Reconstructions are evaluated in an oblique plane along the extent of the object using simple backprojection (SBP) and filtered backprojection (FBP). By comparing the amplitude of the reconstruction against the attenuation coefficient of the object at various frequencies, the modulation transfer function (MTF) is calculated to determine whether modulation is within detectable limits for super-resolution. For experimental validation of super-resolution, a goniometry stand was used to orient a bar pattern phantom along various pitches relative to the breast support in a commercial digital breast tomosynthesis system. Results: Using theoretical modeling, it is shown that a single projection image cannot resolve a sine input whose frequency exceeds the detector alias frequency. The high frequency input is correctly visualized in SBP or FBP reconstruction using a slice along the pitch of the object. The Fourier transform of this reconstructed slice is maximized at the input frequency as proof that the object is resolved. Consistent with the theoretical results, experimental images of a bar pattern phantom showed super-resolution in oblique reconstructions. At various pitches, the highest frequency with detectable modulation was determined by visual inspection of the bar patterns. The dependency of the highest

  16. Isthmocervical labelling and SPECT/CT for optimized sentinel detection in endometrial cancer: technique, experience and results.

    Science.gov (United States)

    Mücke, J; Klapdor, R; Schneider, M; Länger, F; Gratz, K F; Hillemanns, P; Hertel, H

    2014-08-01

    We evaluated the clinical feasibility of a new injection technique for sentinel detection in endometrial carcinoma (EC), transcervical subepithelial injection into the isthmocervical region of the myometrium. We compared detection of sentinel lymph nodes (SLN) by single photon emission computed tomography with CT (SPECT/CT) with planar lymphoscintigraphy. This is a unicentric prospective study. In all patients, transcervical injection of 10 MBq Technetium-99m-nanocolloid was performed into the isthmocervical myometrium without anaesthesia. After 40 (30-60) min, lymphoscintigraphy and SPECT/CT were performed. Patent blue was administered before surgery. The number and localisation of SLN detected in SPECT/CT and lymphoscintigraphy were recorded and compared to the SLN and non-SLN dissected intra-operatively. Between August 2008 and March 2012, 31 patients with EC were enrolled. The new transcervical injection of labelling substances led to high intra-operative (90.3%) detection rates, pelvic bilateral (57%), para-aortic (25%). SPECT/CT significantly identified more SLN than lymphoscintigraphy (mean 2.2 (1-8) to 1.3 (1-7)) in more patients (29/31 (93.5%) to 21/31 (68%), pnegative predictive value (NPV) 100%, and false negative results 0%. Transcervical SLN marking in combination with SPECT/CT is easily applicable and leads to high physiologic detection rates in pelvic and para-aortic lymphatic drainage areas. Non-affected SLN truly predicted a non-affected LN basin. Combining both methods SLN dissection may be a safe and feasible staging technique for clinical routine in EC. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. POTENTIAL OF MULTI-TEMPORAL OBLIQUE AIRBORNE IMAGERY FOR STRUCTURAL DAMAGE ASSESSMENT

    Directory of Open Access Journals (Sweden)

    A. Vetrivel

    2016-06-01

    Full Text Available Quick post-disaster actions demand automated, rapid and detailed building damage assessment. Among the available technologies, post-event oblique airborne images have already shown their potential for this task. However, existing methods usually compensate the lack of pre-event information with aprioristic assumptions of building shapes and textures that can lead to uncertainties and misdetections. However, oblique images have been already captured over many cities of the world, and the exploitation of pre- and post-event data as inputs to damage assessment is readily feasible in urban areas. In this paper, we investigate the potential of multi-temporal oblique imagery for detailed damage assessment focusing on two methodologies: the first method aims at detecting severe structural damages related to geometrical deformation by combining the complementary information provided by photogrammetric point clouds and oblique images. The developed method detected 87% of damaged elements. The failed detections are due to varying noise levels within the point cloud which hindered the recognition of some structural elements. We observed, in general that the façade regions are very noisy in point clouds. To address this, we propose our second method which aims to detect damages to building façades using the oriented oblique images. The results show that the proposed methodology can effectively differentiate among the three proposed categories: collapsed/highly damaged, lower levels of damage and undamaged buildings, using a computationally light-weight approach. We describe the implementations of the above mentioned methods in detail and present the promising results achieved using multi-temporal oblique imagery over the city of L’Aquila (Italy.

  18. Non-aligned pulsar magnetosphere: an illustrative model for small obliquity

    Energy Technology Data Exchange (ETDEWEB)

    Mestel, L.; Wang, Y.M. (Sussex Univ., Brighton (UK). Astronomy Centre)

    1982-02-01

    The electromagnetic field outside a pulsar of small obliquity is approximated by Goldreich-Julian (GJ) conditions out to the light-cylinder and by an outgoing vacuum wave beyond, matched by the appropriate surface charge-current distribution. The energy supply for the wave requires current flow between the pulsar and the light-cylinder. As in the earlier proposal for the aligned rotator, the cold electrons carrying the current achieve relativistic energies near the light-cylinder; the consequent inertial and radiation damping forces enable the electrons to drift across the field-lines and so complete their circuits back to the pulsar. It is hypothesized that low-obliquity pulsars are essentially emitters of a plasma-modified low-frequency wave and of gamma-radiation near the light-cylinder. Illustrative models are constructed as perturbations about an analogous approximate model for the aligned case. The precessional torque component accompanying the braking component acts so as to reduce the obliquity. As long as the obliquity is not too large there is no prima facie objection to non-relativistic flow near the star. It is emphasized that fully self-consistent models will have a smooth rather than a sharp transition between the GJ and vacuum domains.

  19. Residual symptoms after surgery for unilateral congenital superior oblique palsy.

    Science.gov (United States)

    Caca, Ihsan; Sahin, Alparslan; Cingu, Abdullah; Ari, Seyhmus; Akbas, Umut

    2012-01-01

    To establish the surgical results and residual symptoms in 48 cases with unilateral congenital superior oblique muscle palsy that had surgical intervention to the vertical muscles alone. Myectomy and concomitant disinsertion of the inferior oblique (IO) muscle was performed in 38 cases and myectomy and concomitant IO disinsertion and recession of the superior rectus muscle in the ipsilateral eye was performed in 10 cases. The preoperative and postoperative vertical deviation values and surgical results were compared. Of the patients who had myectomy and concomitant IO disinsertion, 74% achieved an "excellent" result, 21% a "good" result, and 5% a "poor" result postoperatively. The difference in deviation between preoperative and postoperative values was statistically significant (P < .001). Of the patients who had myectomy and concomitant inferior oblique disinsertion and ipsilateral superior rectus recession, 50% achieved an "excellent" result, 20% a "good" result, and 30% a "poor" result postoperatively. The difference in deviation between preoperative and postoperative values was statistically significant (P < .001). Both procedures are effective and successful in patients with superior oblique muscle palsy, but a secondary surgery may be required. Copyright 2012, SLACK Incorporated.

  20. Obliquely Propagating Non-Monotonic Double Layer in a Hot Magnetized Plasma

    International Nuclear Information System (INIS)

    Kim, T.H.; Kim, S.S.; Hwang, J.H.; Kim, H.Y.

    2005-01-01

    Obliquely propagating non-monotonic double layer is investigated in a hot magnetized plasma, which consists of a positively charged hot ion fluid and trapped, as well as free electrons. A model equation (modified Korteweg-de Vries equation) is derived by the usual reductive perturbation method from a set of basic hydrodynamic equations. A time stationary obliquely propagating non-monotonic double layer solution is obtained in a hot magnetized-plasma. This solution is an analytic extension of the monotonic double layer and the solitary hole. The effects of obliqueness, external magnetic field and ion temperature on the properties of the non-monotonic double layer are discussed

  1. An "oblique effect" in the visual evoked potential of the cat.

    Science.gov (United States)

    Bonds, A B

    1982-01-01

    An oblique effect was observed in the amplitude of the VEP recorded from area 17 of the cat. The ratio of the responses to oblique gratings compared with responses to horizontal and vertical gratings averaged 0.77. Orientation dependence was strongest at low spatial frequencies, unlike the effect found in primates.

  2. Oblique Modulation of Ion-Acoustic Waves in a Warm Plasma

    International Nuclear Information System (INIS)

    Xue Jukui; Tang Rongan

    2003-01-01

    The stability of oblique modulation of ion-acoustic waves in an unmagnetized warm plasma is studied. A nonlinear Schroedinger equation governing the slow modulation of the wave amplitude is derived. The effect of temperature on the oblique modulational instability of the ion-acoustic wave is investigated. It is found that the ion temperature significantly changes the domain of the modulational instability in the k-θ plane

  3. Generation and Micro-scale Effects of Electrostatic Waves in an Oblique Shock

    Science.gov (United States)

    Goodrich, K.; Ergun, R.; Schwartz, S. J.; Newman, D.; Johlander, A.; Argall, M. R.; Wilder, F. D.; Torbert, R. B.; Khotyaintsev, Y. V.; Lindqvist, P. A.; Strangeway, R. J.; Russell, C. T.; Giles, B. L.; Gershman, D. J.; Burch, J. L.

    2017-12-01

    We present an analysis of large amplitude (>100 mV/m), high frequency (≤1 kHz), electrostatic waves observed by MMS during an oblique bow shock crossing event. The observed waves primarily consist of electrostatic solitary waves (ESWs) and oblique ion plasma waves (IPWs). ESWs typically include nonlinear structures such as double layers, ion phase-space holes, and electron phase-space holes. Oblique IPWs are observed to be similar to ion acoustic waves, but can propagate up to 70° from the ambient magnetic field direction. Both wave-modes, particularly IPWs, are observed to have very short wavelengths ( 100 m) and are highly localized. While such wave-modes have been previously observed in the terrestrial bow shock, instrumental constraints have limited detailed insight into their generation and their effect on their plasma shock environment. Analysis of this oblique shock event shows evidence that ESWs and oblique IPWs can be generated through field-aligned currents associated with magnetic turbulence and through a counterstreaming ion instability respectively. We also present evidence that this wave activity can facilitate momentum exchange between ion populations, resulting in deceleration of incoming solar wind, and localized electron heating.

  4. Spatial and Temporal Variations in Slip Partitioning During Oblique Convergence Experiments

    Science.gov (United States)

    Beyer, J. L.; Cooke, M. L.; Toeneboehn, K.

    2017-12-01

    first non-planar oblique slip fault, strain energy density is greatest where the first fault is steepest, as less convergence is accommodated along this portion of the fault. The addition of a second slip-partitioning fault to the system decreases external work indicating that these faults increase the mechanical efficiency of the system.

  5. Gross chylous ascites in cirrhosis with massive portal vein thrombosis: diagnostic value of lymphoscintigraphy. A case report and review of the literature.

    Science.gov (United States)

    Archimandritis, Athanasios J; Zonios, Dimitrios I; Karadima, Dimitra; Vlachoyiannopoulos, Panagiotis G; Kiriaki, Despina; Hatzis, Grigorios S

    2003-01-01

    Chylous ascites is an uncommon condition, which could be due to various causes. We report a case of gross chylous ascites in a patient with cirrhosis and portal vein thrombosis. It is confirmed that gross chylous ascites in a patient with cirrhosis and portal vein thrombosis heralds an ominous prognosis for the patient. Results also demonstrate that common therapeutic interventions confer minimal benefit to the patient, whose survival may be limited to a few months. The use of lymphoscintigraphy as a convenient method for diagnostic exploration of the chylous ascites is emphasized, as it does not lead to complications or adverse effects, and can be readily repeated as needed. Copyright 2003 Lippincott Williams & Wilkins

  6. Planar graphs theory and algorithms

    CERN Document Server

    Nishizeki, T

    1988-01-01

    Collected in this volume are most of the important theorems and algorithms currently known for planar graphs, together with constructive proofs for the theorems. Many of the algorithms are written in Pidgin PASCAL, and are the best-known ones; the complexities are linear or 0(nlogn). The first two chapters provide the foundations of graph theoretic notions and algorithmic techniques. The remaining chapters discuss the topics of planarity testing, embedding, drawing, vertex- or edge-coloring, maximum independence set, subgraph listing, planar separator theorem, Hamiltonian cycles, and single- or multicommodity flows. Suitable for a course on algorithms, graph theory, or planar graphs, the volume will also be useful for computer scientists and graph theorists at the research level. An extensive reference section is included.

  7. The Oblique Basis Method from an Engineering Point of View

    International Nuclear Information System (INIS)

    Gueorguiev, V G

    2012-01-01

    The oblique basis method is reviewed from engineering point of view related to vibration and control theory. Examples are used to demonstrate and relate the oblique basis in nuclear physics to the equivalent mathematical problems in vibration theory. The mathematical techniques, such as principal coordinates and root locus, used by vibration and control theory engineers are shown to be relevant to the Richardson - Gaudin pairing-like problems in nuclear physics.

  8. The visibility of mandibular canal on orthoradial and oblique CBCT slices at molar implant sites

    International Nuclear Information System (INIS)

    Alkhader, Mustafa; Jarab, Fadi; Shaweesh, Ashraf; Hudieb, Malik

    2016-01-01

    The aim of the present study was to compare visibility of the mandibular canal on cone beam computed tomography (CBCT)-based orthoradial and oblique slices at molar implant sites. CBCT images for 132 mandibular molar implant sites were selected for the study. After generating orthoradial and oblique slices, two observers evaluated the visibility of the mandibular canal using three-point scoring scale (1-3, good to excellent). Wilcoxon signed-rank test compared the visibility scores of the two slices. Both orthoradial and oblique slices obtained from CBCT had only very good to excellent mandibular canal visibility scores. At 114 mandibular molar implant sites, the visibility score was equal on both orthoradial and oblique slices. Although the visibility score was higher on orthoradial slices for 12 implant sites, the visibility score was higher for six implant sites on oblique slices and the difference was not significant. Therefore, the visibility of the mandibular canal was excellent and comparable on most of orthoradial and oblique slices obtained from CBCT images

  9. Tibiofibular syndesmosis in acute ankle fractures: additional value of an oblique MR image plane

    International Nuclear Information System (INIS)

    Hermans, John J.; Ginai, Abida Z.; Beumer, Annechien; Moonen, Adrianus F.C.M.; Hop, Wim C.J.

    2012-01-01

    To evaluate the additional value of a 45 oblique MRI scan plane for assessing the anterior and posterior distal tibiofibular syndesmotic ligaments in patients with an acute ankle fracture. Prospectively, data were collected for 44 consecutive patients with an acute ankle fracture who underwent a radiograph (AP, lateral, and mortise view) as well as an MRI in both the standard three orthogonal planes and in an additional 45 oblique plane. The fractures on the radiographs were classified according to Lauge-Hansen (LH). The anterior (ATIFL) and posterior (PTIFL) distal tibiofibular ligaments, as well as the presence of a bony avulsion in both the axial and oblique planes was evaluated on MRI. MRI findings regarding syndesmotic injury in the axial and oblique planes were compared to syndesmotic injury predicted by LH. Kappa and the agreement score were calculated to determine the interobserver agreement. The Wilcoxon signed rank test and McNemar's test were used to compare the two scan planes. The interobserver agreement (κ) and agreement score [AS (%)] regarding injury of the ATIFL and PTIFL and the presence of a fibular or tibial avulsion fracture were good to excellent in both the axial and oblique image planes (κ 0.61-0.92, AS 84-95%). For both ligaments the oblique image plane indicated significantly less injury than the axial plane (p < 0.001). There was no significant difference in detection of an avulsion fracture in the axial or oblique plane, neither anteriorly (p=0.50) nor posteriorly (p=1.00). With syndesmotic injury as predicted by LH as comparison, the specificity in the oblique MR plane increased for both anterior (to 86% from 7%) and posterior (to 86% from 48%) syndesmotic injury when compared to the axial plane. Our results show the additional value of an 45 oblique MR image plane for detection of injury of the anterior and posterior distal tibiofibular syndesmoses in acute ankle fractures. Findings of syndesmotic injury in the oblique MRI plane were

  10. Tibiofibular syndesmosis in acute ankle fractures: additional value of an oblique MR image plane

    Energy Technology Data Exchange (ETDEWEB)

    Hermans, John J.; Ginai, Abida Z. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Beumer, Annechien; Moonen, Adrianus F.C.M. [Amphia Hospital, Department of Orthopaedics, Breda (Netherlands); Hop, Wim C.J. [Erasmus University Medical Center, Department of Biostatistics, Rotterdam (Netherlands)

    2012-02-15

    To evaluate the additional value of a 45 oblique MRI scan plane for assessing the anterior and posterior distal tibiofibular syndesmotic ligaments in patients with an acute ankle fracture. Prospectively, data were collected for 44 consecutive patients with an acute ankle fracture who underwent a radiograph (AP, lateral, and mortise view) as well as an MRI in both the standard three orthogonal planes and in an additional 45 oblique plane. The fractures on the radiographs were classified according to Lauge-Hansen (LH). The anterior (ATIFL) and posterior (PTIFL) distal tibiofibular ligaments, as well as the presence of a bony avulsion in both the axial and oblique planes was evaluated on MRI. MRI findings regarding syndesmotic injury in the axial and oblique planes were compared to syndesmotic injury predicted by LH. Kappa and the agreement score were calculated to determine the interobserver agreement. The Wilcoxon signed rank test and McNemar's test were used to compare the two scan planes. The interobserver agreement ({kappa}) and agreement score [AS (%)] regarding injury of the ATIFL and PTIFL and the presence of a fibular or tibial avulsion fracture were good to excellent in both the axial and oblique image planes ({kappa} 0.61-0.92, AS 84-95%). For both ligaments the oblique image plane indicated significantly less injury than the axial plane (p < 0.001). There was no significant difference in detection of an avulsion fracture in the axial or oblique plane, neither anteriorly (p=0.50) nor posteriorly (p=1.00). With syndesmotic injury as predicted by LH as comparison, the specificity in the oblique MR plane increased for both anterior (to 86% from 7%) and posterior (to 86% from 48%) syndesmotic injury when compared to the axial plane. Our results show the additional value of an 45 oblique MR image plane for detection of injury of the anterior and posterior distal tibiofibular syndesmoses in acute ankle fractures. Findings of syndesmotic injury in the oblique

  11. 3D reconnection due to oblique modes: a simulation of Harris current sheets

    Directory of Open Access Journals (Sweden)

    G. Lapenta

    2000-01-01

    Full Text Available Simulations in three dimensions of a Harris current sheet with mass ratio, mi/me = 180, and current sheet thickness, pi/L = 0.5, suggest the existence of a linearly unstable oblique mode, which is independent from either the drift-kink or the tearing instability. The new oblique mode causes reconnection independently from the tearing mode. During the initial linear stage, the system is unstable to the tearing mode and the drift kink mode, with growth rates that are accurately described by existing linear theories. How-ever, oblique modes are also linearly unstable, but with smaller growth rates than either the tearing or the drift-kink mode. The non-linear stage is first reached by the drift-kink mode, which alters the initial equilibrium and leads to a change in the growth rates of the tearing and oblique modes. In the non-linear stage, the resulting changes in magnetic topology are incompatible with a pure tearing mode. The oblique mode is shown to introduce a helical structure into the magnetic field lines.

  12. Oblique lumbar spine radiographs: importance in young patients

    Energy Technology Data Exchange (ETDEWEB)

    Libson, E.; Bloom, R.A.; Dinari, G.; Robin, G.C.

    1984-04-01

    Spondylolysis is a direct precursor of spondylolisthesis and can lead to crippling back pain. Of 1,743 patients surveyed, including 936 who were asymptomatic and 807 with back pain, 165 (including 91 who were asymptomatic and 74 with back pain) had spondylolysis, which was seen only on oblique lumbar views in 20% of cases. Because of the high false-negative rate of AP and lateral views, oblique views are essential in children and young adults. As spondylolysis is rare above L3, radiographs can be limited to L3-S1. Significantly less spondylolysis was seen in persons older than 30 with back pain usually caused by disk degeneration.

  13. Oblique lumbar spine radiographs: importance in young patients

    International Nuclear Information System (INIS)

    Libson, E.; Bloom, R.A.; Dinari, G.; Robin, G.C.

    1984-01-01

    Spondylolysis is a direct precursor of spondylolisthesis and can lead to crippling back pain. Of 1,743 patients surveyed, including 936 who were asymptomatic and 807 with back pain, 165 (including 91 who were asymptomatic and 74 with back pain) had spondylolysis, which was seen only on oblique lumbar views in 20% of cases. Because of the high false-negative rate of AP and lateral views, oblique views are essential in children and young adults. As spondylolysis is rare above L3, radiographs can be limited to L3-S1. Significantly less spondylolysis was seen in persons older than 30 with back pain usually caused by disk degeneration

  14. Effect of bilateral superior oblique split lengthening on torsion

    Directory of Open Access Journals (Sweden)

    Jitendra Jethani

    2015-01-01

    Full Text Available Introduction: Superior oblique split lengthening (SOSL is done for weakening of superior oblique. It corrects the superior oblique overaction (SOOA and A pattern. Its effect on the torsion of the eye is not known. We present our data on the effect of this particular procedure on torsion. Materials and Methods: We did a study of 16 patients (32 eyes who underwent bilateral SOSL and compared the disc foveal angle (DFA preoperatively and postoperatively. The split lengthening was done from 4 mm to 7 mm depending upon the overaction of superior oblique. Results: The mean age was 15.3 ± 8.4 years. Mean preoperative DFA in the right eye (RE was −3.9° and in the left eye (LE was −2.9°. Mean postoperative DFA in RE was 0.2° and in LE was 0.9°. The mean change in the DFA for RE was 4.1° ± 1.3° and for LE was 3.8° ± 1.2°. All the patients were aligned horizontally within 6 prism diopter and no pattern and no diplopia postoperatively. The A pattern was corrected in all the patient postsurgery. For each mm of surgery, an improvement of 0.8° was seen in the DFA. Conclusion: We report the effect of SOSL on torsion. The SOSL reduces intorsion postsurgery and is, therefore, a valuable procedure in SOOA where both pattern and in torsion needs to be corrected.

  15. In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

    Science.gov (United States)

    Tersi, Luca; Barré, Arnaud; Fantozzi, Silvia; Stagni, Rita

    2013-03-01

    Model-based mono-planar and bi-planar 3D fluoroscopy methods can quantify intact joints kinematics with performance/cost trade-off. The aim of this study was to compare the performances of mono- and bi-planar setups to a marker-based gold-standard, during dynamic phantom knee acquisitions. Absolute pose errors for in-plane parameters were lower than 0.6 mm or 0.6° for both mono- and bi-planar setups. Mono-planar setups resulted critical in quantifying the out-of-plane translation (error bi-planar in quantifying the rotation along bone longitudinal axis (error bi-planar (error comparable to bi-planar, but with halved computational costs, halved segmentation time and halved ionizing radiation dose. Bi-planar analysis better compensated for the out-of-plane uncertainty that is differently propagated to relative kinematics depending on the setup. To take its full benefits, the motion task to be investigated should be designed to maintain the joint inside the visible volume introducing constraints with respect to mono-planar analysis.

  16. A note on oblique water entry

    KAUST Repository

    Moore, M. R.; Howison, S. D.; Ockendon, J. R.; Oliver, J. M.

    2012-01-01

    A minor error in Howison et al. (J. Eng. Math. 48:321-337, 2004) obscured the fact that the points at which the free surface turns over in the solution of the Wagner model for the oblique impact of a two-dimensional body are directly related

  17. Youngswick-Austin versus distal oblique osteotomy for the treatment of Hallux Rigidus.

    Science.gov (United States)

    Viladot, Antonio; Sodano, Luca; Marcellini, Lorenzo; Zamperetti, Marco; Hernandez, Elsa Sanchez; Perice, Ramon Viladot

    2017-08-01

    Hallux Rigidus is the most common degenerative joint pathology of the foot. Several procedures are described for the management of this deformity. In this prospective study we compared Youngswick-Austin and distal oblique osteotomy in the treatment of grade II Hallux Rigidus, in terms of clinical outcomes, efficacy and complications. Forty-six patients (50 feet) with moderate Hallux Rigidus (Regnauld grade II) were recruited and operated between March 2009 and December 2012. Surgical technique was Youngswick-Austin osteotomy (Group A) or distal oblique osteotomy (Group B). Mean follow-up was 42.7 ±12.2 (range, 24-70) months. Both groups achieved significant improvement of AOFAS score and first metatarsophalangeal joint range of motion (p value Austin and distal oblique osteotomies provides subjective patient improvement and increases the first metatarsophalangeal joint range of motion. The results of grade II Hallux Rigidus treatment were comparable when using a Youngswick-Austin or distal oblique osteotomy. Level II, prospective comparative study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Oblique-Flying-Wing Supersonic Transport Airplane

    Science.gov (United States)

    Van Der Velden, Alexander J. M.

    1992-01-01

    Oblique-flying-wing supersonic airplane proposed as possible alternative to B747B (or equivalent). Tranports passengers and cargo as fast as twice speed of sound at same cost as current subsonic transports. Flies at same holding speeds as present supersonic transports but requires only half takeoff distance.

  19. Accuracy Potential and Applications of MIDAS Aerial Oblique Camera System

    Science.gov (United States)

    Madani, M.

    2012-07-01

    Airborne oblique cameras such as Fairchild T-3A were initially used for military reconnaissance in 30s. A modern professional digital oblique camera such as MIDAS (Multi-camera Integrated Digital Acquisition System) is used to generate lifelike three dimensional to the users for visualizations, GIS applications, architectural modeling, city modeling, games, simulators, etc. Oblique imagery provide the best vantage for accessing and reviewing changes to the local government tax base, property valuation assessment, buying & selling of residential/commercial for better decisions in a more timely manner. Oblique imagery is also used for infrastructure monitoring making sure safe operations of transportation, utilities, and facilities. Sanborn Mapping Company acquired one MIDAS from TrackAir in 2011. This system consists of four tilted (45 degrees) cameras and one vertical camera connected to a dedicated data acquisition computer system. The 5 digital cameras are based on the Canon EOS 1DS Mark3 with Zeiss lenses. The CCD size is 5,616 by 3,744 (21 MPixels) with the pixel size of 6.4 microns. Multiple flights using different camera configurations (nadir/oblique (28 mm/50 mm) and (50 mm/50 mm)) were flown over downtown Colorado Springs, Colorado. Boresight fights for 28 mm nadir camera were flown at 600 m and 1,200 m and for 50 mm nadir camera at 750 m and 1500 m. Cameras were calibrated by using a 3D cage and multiple convergent images utilizing Australis model. In this paper, the MIDAS system is described, a number of real data sets collected during the aforementioned flights are presented together with their associated flight configurations, data processing workflow, system calibration and quality control workflows are highlighted and the achievable accuracy is presented in some detail. This study revealed that the expected accuracy of about 1 to 1.5 GSD (Ground Sample Distance) for planimetry and about 2 to 2.5 GSD for vertical can be achieved. Remaining systematic

  20. ACCURACY POTENTIAL AND APPLICATIONS OF MIDAS AERIAL OBLIQUE CAMERA SYSTEM

    Directory of Open Access Journals (Sweden)

    M. Madani

    2012-07-01

    Full Text Available Airborne oblique cameras such as Fairchild T-3A were initially used for military reconnaissance in 30s. A modern professional digital oblique camera such as MIDAS (Multi-camera Integrated Digital Acquisition System is used to generate lifelike three dimensional to the users for visualizations, GIS applications, architectural modeling, city modeling, games, simulators, etc. Oblique imagery provide the best vantage for accessing and reviewing changes to the local government tax base, property valuation assessment, buying & selling of residential/commercial for better decisions in a more timely manner. Oblique imagery is also used for infrastructure monitoring making sure safe operations of transportation, utilities, and facilities. Sanborn Mapping Company acquired one MIDAS from TrackAir in 2011. This system consists of four tilted (45 degrees cameras and one vertical camera connected to a dedicated data acquisition computer system. The 5 digital cameras are based on the Canon EOS 1DS Mark3 with Zeiss lenses. The CCD size is 5,616 by 3,744 (21 MPixels with the pixel size of 6.4 microns. Multiple flights using different camera configurations (nadir/oblique (28 mm/50 mm and (50 mm/50 mm were flown over downtown Colorado Springs, Colorado. Boresight fights for 28 mm nadir camera were flown at 600 m and 1,200 m and for 50 mm nadir camera at 750 m and 1500 m. Cameras were calibrated by using a 3D cage and multiple convergent images utilizing Australis model. In this paper, the MIDAS system is described, a number of real data sets collected during the aforementioned flights are presented together with their associated flight configurations, data processing workflow, system calibration and quality control workflows are highlighted and the achievable accuracy is presented in some detail. This study revealed that the expected accuracy of about 1 to 1.5 GSD (Ground Sample Distance for planimetry and about 2 to 2.5 GSD for vertical can be achieved. Remaining

  1. The role of the reversed oblique radiograph in trauma of the foot and ankle

    International Nuclear Information System (INIS)

    Geusens, E.; Geyskens, W.; Brys, P.; Janzing, H.

    2000-01-01

    The objective of this study was to demonstrate the statistical significance of a reversed oblique radiograph of the foot in patients with ankle or foot trauma. In 100 consecutive patients a reversed oblique radiograph of the foot was taken in addition to the conventional plain films. Ten of 29 fractures were not visualised on the conventional films of foot and ankle and could only be diagnosed on the reversed oblique film. In 7 of these 10 cases an avulsion fracture at the anterolateral aspect of the calcaneus was present. This additional reversed oblique film of the foot seems to be of considerable importance, especially when an anterolateral avulsion fracture of the calcaneus is clinically suspected. (orig.)

  2. The role of the reversed oblique radiograph in trauma of the foot and ankle

    Energy Technology Data Exchange (ETDEWEB)

    Geusens, E.; Geyskens, W.; Brys, P. [Dept. of Radiology, University Hospitals, Leuven (Belgium); Janzing, H. [Dept. of Traumatology, University Hospitals, Leuven (Belgium)

    2000-03-01

    The objective of this study was to demonstrate the statistical significance of a reversed oblique radiograph of the foot in patients with ankle or foot trauma. In 100 consecutive patients a reversed oblique radiograph of the foot was taken in addition to the conventional plain films. Ten of 29 fractures were not visualised on the conventional films of foot and ankle and could only be diagnosed on the reversed oblique film. In 7 of these 10 cases an avulsion fracture at the anterolateral aspect of the calcaneus was present. This additional reversed oblique film of the foot seems to be of considerable importance, especially when an anterolateral avulsion fracture of the calcaneus is clinically suspected. (orig.)

  3. Integral particle reflection coefficient for oblique incidence of photons as universal function in the domain of initial energies up to 300 keV

    Directory of Open Access Journals (Sweden)

    Ljubenov Vladan L.

    2014-01-01

    Full Text Available In this paper we present the results of calculations and analyses of the integral particle reflection coefficient of photons for oblique photon incidence on planar targets, in the domain of initial photon energies from 100 keV to 300 keV. The results are based on the Monte Carlo simulations of the photon reflection from water, concrete, aluminum, iron, and copper materials, performed by the MCNP code. It has been observed that the integral particle reflection coefficient as a function of the ratio of total cross-section of photons and effective atomic number of target material shows universal behavior for all the analyzed shielding materials in the selected energy domain. Analytical formulas for different angles of photon incidence have been proposed, which describe the reflection of photons for all the materials and energies analyzed.

  4. Three-Dimensional Simulations of Oblique Asteroid Impacts into Water

    Science.gov (United States)

    Gisler, G. R.; Ferguson, J. M.; Heberling, T.; Plesko, C. S.; Weaver, R.

    2016-12-01

    Waves generated by impacts into oceans may represent the most significant danger from near-earth asteroids and comets. For impacts near populated shores, the crown splash and subsequent waves, accompanied by sediment lofting and high winds, could be more damaging than storm surges from the strongest hurricanes. For asteroids less than 500 m in diameter that impact into deep water far from shores, the waves produced will be detectable over large distances, but probably not significantly dangerous. We present new three-dimensional simulations of oblique impacts into deep water, with trajectory angles ranging from 20 degrees to 60 degrees (where 90 degrees is vertical). These simulations are performed with the Los Alamos Rage hydrocode, and include atmospheric effects including ablation and airbursts. These oblique impact simulations are specifically performed in order to help determine whether there are additional dangers from the obliquity of impact not covered by previous two-dimensional studies. Water surface elevation profiles, surface pressures, and depth-averaged mass fluxes within the water are prepared for use in propagation studies.

  5. Spatial evolution of Zagros collision zone in Kurdistan, NW Iran: constraints on Arabia-Eurasia oblique convergence

    Science.gov (United States)

    Sadeghi, Shahriar; Yassaghi, Ali

    2016-04-01

    Stratigraphy, detailed structural mapping and a crustal-scale cross section across the NW Zagros collision zone provide constraints on the spatial evolution of oblique convergence of the Arabian and Eurasian plates since the Late Cretaceous. The Zagros collision zone in NW Iran consists of the internal Sanandaj-Sirjan, Gaveh Rud and Ophiolite zones and the external Bisotoun, Radiolarite and High Zagros zones. The Main Zagros Thrust is the major structure of the Zagros suture zone. Two stages of oblique deformation are recognized in the external part of the NW Zagros in Iran. In the early stage, coexisting dextral strike-slip and reverse dominated domains in the Radiolarite zone developed in response to deformation partitioning due to oblique convergence. Dextral-reverse faults in the Bisotoun zone are also compatible with oblique convergence. In the late stage, deformation partitioning occurred during southeastward propagation of the Zagros orogeny towards its foreland resulting in synchronous development of orogen-parallel strike-slip and thrust faults. It is proposed that the first stage was related to Late Cretaceous oblique obduction, while the second stage resulted from Cenozoic collision. The Cenozoic orogen-parallel strike-slip component of Zagros oblique convergence is not confined to the Zagros suture zone (Main Recent Fault) but also occurred in the external part (Marekhil-Ravansar fault system). Thus, it is proposed that oblique convergence of Arabian and Eurasian plates in Zagros collision zone initiated with oblique obduction in the Late Cretaceous followed by oblique collision in the late Tertiary, consistent with global plate reconstructions.

  6. The influence of the oblique incident X-ray that affected the image quality of the X-ray CCD sensor

    International Nuclear Information System (INIS)

    Suzuki, Yosuke; Matsumoto, Nobue; Morita, Hiroshi; Ohkawa, Hiromitsu

    1998-01-01

    The influence of the oblique incident X-ray that affected the image quality of the X-ray CCD sensor was examined and its correction was investigated. CDR was adopted in this study and evaluated image quality, by measuring MTF. The oblique projection was clinically permissible to about an oblique incident angle of 40 degrees although it exerts an influence on the magnifying power and density. The estimation of the oblique entrance direction and oblique incident angle was possible, by developing an oblique incident correction marker. When an oblique incident angle of θ degrees was measured, a correction is possible, by compressing the image cos (θ) times perpendicular to the rotational axis of CCD sensor. There was small decline of MTF, in the image where a correction for the influence of oblique incidence was made. By observation of the digital subtracted picture of the image after correction of oblique projection and that of normal, the resemblance in the two images indicated that this correction method was reasonable. (author)

  7. Atmospheric dynamics and habitability range in Earth-like aquaplanets obliquity simulations

    Science.gov (United States)

    Nowajewski, Priscilla; Rojas, M.; Rojo, P.; Kimeswenger, S.

    2018-05-01

    We present the evolution of the atmospheric variables that affect planetary climate by increasing the obliquity by using a general circulation model (PlaSim) coupled to a slab ocean with mixed layer flux correction. We increase the obliquity between 30° and 90° in 16 aquaplanets with liquid sea surface and perform the simulation allowing the sea ice cover formation to be a consequence of its atmospheric dynamics. Insolation is maintained constant in each experiment, but changing the obliquity affects the radiation budget and the large scale circulation. Earth-like atmospheric dynamics is observed for planets with obliquity under 54°. Above this value, the latitudinal temperature gradient is reversed giving place to a new regime of jet streams, affecting the shape of Hadley and Ferrel cells and changing the position of the InterTropical Convergence Zone. As humidity and high temperatures determine Earth's habitability, we introduce the wet bulb temperature as an atmospheric index of habitability for Earth-like aquaplanets with above freezing temperatures. The aquaplanets are habitable all year round at all latitudes for values under 54°; above this value habitability decreases toward the poles due to high temperatures.

  8. Quality Inspection and Analysis of Three-Dimensional Geographic Information Model Based on Oblique Photogrammetry

    Science.gov (United States)

    Dong, S.; Yan, Q.; Xu, Y.; Bai, J.

    2018-04-01

    In order to promote the construction of digital geo-spatial framework in China and accelerate the construction of informatization mapping system, three-dimensional geographic information model emerged. The three-dimensional geographic information model based on oblique photogrammetry technology has higher accuracy, shorter period and lower cost than traditional methods, and can more directly reflect the elevation, position and appearance of the features. At this stage, the technology of producing three-dimensional geographic information models based on oblique photogrammetry technology is rapidly developing. The market demand and model results have been emerged in a large amount, and the related quality inspection needs are also getting larger and larger. Through the study of relevant literature, it is found that there are a lot of researches on the basic principles and technical characteristics of this technology, and relatively few studies on quality inspection and analysis. On the basis of summarizing the basic principle and technical characteristics of oblique photogrammetry technology, this paper introduces the inspection contents and inspection methods of three-dimensional geographic information model based on oblique photogrammetry technology. Combined with the actual inspection work, this paper summarizes the quality problems of three-dimensional geographic information model based on oblique photogrammetry technology, analyzes the causes of the problems and puts forward the quality control measures. It provides technical guidance for the quality inspection of three-dimensional geographic information model data products based on oblique photogrammetry technology in China and provides technical support for the vigorous development of three-dimensional geographic information model based on oblique photogrammetry technology.

  9. QUALITY INSPECTION AND ANALYSIS OF THREE-DIMENSIONAL GEOGRAPHIC INFORMATION MODEL BASED ON OBLIQUE PHOTOGRAMMETRY

    Directory of Open Access Journals (Sweden)

    S. Dong

    2018-04-01

    Full Text Available In order to promote the construction of digital geo-spatial framework in China and accelerate the construction of informatization mapping system, three-dimensional geographic information model emerged. The three-dimensional geographic information model based on oblique photogrammetry technology has higher accuracy, shorter period and lower cost than traditional methods, and can more directly reflect the elevation, position and appearance of the features. At this stage, the technology of producing three-dimensional geographic information models based on oblique photogrammetry technology is rapidly developing. The market demand and model results have been emerged in a large amount, and the related quality inspection needs are also getting larger and larger. Through the study of relevant literature, it is found that there are a lot of researches on the basic principles and technical characteristics of this technology, and relatively few studies on quality inspection and analysis. On the basis of summarizing the basic principle and technical characteristics of oblique photogrammetry technology, this paper introduces the inspection contents and inspection methods of three-dimensional geographic information model based on oblique photogrammetry technology. Combined with the actual inspection work, this paper summarizes the quality problems of three-dimensional geographic information model based on oblique photogrammetry technology, analyzes the causes of the problems and puts forward the quality control measures. It provides technical guidance for the quality inspection of three-dimensional geographic information model data products based on oblique photogrammetry technology in China and provides technical support for the vigorous development of three-dimensional geographic information model based on oblique photogrammetry technology.

  10. A Double Zone Dynamical Model For The Tidal Evolution Of The Obliquity

    Science.gov (United States)

    Damiani, Cilia

    2017-10-01

    It is debated wether close-in giants planets can form in-situ and if not, which mechanisms are responsible for their migration. One of the observable tests for migration theories is the current value of the obliquity. But after the main migration mechanism has ended, the combined effects of tidal dissipation and the magnetic braking of the star lead to the evolution of both the obliquity and the semi-major axis. The observed correlation between effective temperature and measured projected obliquity has been taken as evidence of such mechanisms being at play. Here I present an improved model for the tidal evolution of the obliquity. It includes all the components of the dynamical tide for circular misaligned systems. It uses an analytical formulation for the frequency-averaged dissipation for each mode, depending only on global stellar parameters, giving a measure of the dissipative properties of the convective zone of the host as it evolves in time. The model also includes the effect of magnetic braking in the framework of the double zone model. This results in the estimation of different tidal evolution timescales for the evolution of the planet's semi-major axis and obliquity depending on the properties of the stellar host. This model can be used to test migration theories, provided that a good determination of stellar radii, masses and ages can be obtained.

  11. Microstructural and magnetic properties of thin obliquely deposited films: A simulation approach

    Energy Technology Data Exchange (ETDEWEB)

    Solovev, P.N., E-mail: platon.solovev@gmail.com [Kirensky Institute of Physics, Siberian Branch of the Russian Academy of Sciences, 50/38, Akademgorodok, Krasnoyarsk 660036 (Russian Federation); Siberian Federal University, 79, pr. Svobodnyi, Krasnoyarsk 660041 (Russian Federation); Izotov, A.V. [Kirensky Institute of Physics, Siberian Branch of the Russian Academy of Sciences, 50/38, Akademgorodok, Krasnoyarsk 660036 (Russian Federation); Siberian Federal University, 79, pr. Svobodnyi, Krasnoyarsk 660041 (Russian Federation); Belyaev, B.A. [Kirensky Institute of Physics, Siberian Branch of the Russian Academy of Sciences, 50/38, Akademgorodok, Krasnoyarsk 660036 (Russian Federation); Siberian Federal University, 79, pr. Svobodnyi, Krasnoyarsk 660041 (Russian Federation); Reshetnev Siberian State Aerospace University, 31, pr. Imeni Gazety “Krasnoyarskii Rabochii”, Krasnoyarsk 660014 (Russian Federation)

    2017-05-01

    The relation between microstructural and magnetic properties of thin obliquely deposited films has been studied by means of numerical techniques. Using our developed simulation code based on ballistic deposition model and Fourier space approach, we have investigated dependences of magnetometric tensor components and magnetic anisotropy parameters on the deposition angle of the films. A modified Netzelmann approach has been employed to study structural and magnetic parameters of an isolated column in the samples with tilted columnar microstructure. Reliability and validity of used numerical methods is confirmed by a good agreement of the calculation results with each other, as well as with our experimental data obtained by the ferromagnetic resonance measurements of obliquely deposited thin Ni{sub 80}Fe{sub 20} films. The combination of these numerical methods can be used to design a magnetic film with a desirable value of uniaxial magnetic anisotropy and to extract the obliquely deposited film structure from only magnetic measurements. - Highlights: • We present a simulation approach to study a relation between structural and magnetic properties of oblique films. • The calculated dependence of magnetic anisotropy on a deposition angle accords well with the experiment. • A modified Netzelmann approach is proposed. • It allows for the computation of magnetic and structural parameters of an isolated column. • Proposed approach can be used for theoretical studies and for characterization of oblique films.

  12. Comparison of two different segmentation methods on planar lung perfusion scan with reference to quantitative value on SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Min Seok; Kang, Yeon Koo; Ha, Seung Gyun [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); and others

    2017-06-15

    Until now, there was no single standardized regional segmentation method of planar lung perfusion scan. We compared planar scan based two segmentation methods, which are frequently used in the Society of Nuclear Medicine, with reference to the lung perfusion single photon emission computed tomography (SPECT)/computed tomography (CT) derived values in lung cancer patients. Fifty-five lung cancer patients (male:female, 37:18; age, 67.8 ± 10.7 years) were evaluated. The patients underwent planar scan and SPECT/CT after injection of technetium-99 m macroaggregated albumin (Tc-99 m-MAA). The % uptake and predicted postoperative percentage forced expiratory volume in 1 s (ppoFEV1%) derived from both posterior oblique (PO) and anterior posterior (AP) methods were compared with SPECT/CT derived parameters. Concordance analysis, paired comparison, reproducibility analysis and spearman correlation analysis were conducted. The % uptake derived from PO method showed higher concordance with SPECT/CT derived % uptake in every lobe compared to AP method. Both methods showed significantly different lobar distribution of % uptake compared to SPECT/CT. For the target region, ppoFEV1% measured from PO method showed higher concordance with SPECT/CT, but lower reproducibility compared to AP method. Preliminary data revealed that every method significantly correlated with actual postoperative FEV1%, with SPECT/CT showing the best correlation. The PO method derived values showed better concordance with SPECT/CT compared to the AP method. Both PO and AP methods showed significantly different lobar distribution compared to SPECT/CT. In clinical practice such difference according to different methods and lobes should be considered for more accurate postoperative lung function prediction.

  13. Recent progress of obliquely deposited thin films for industrial applications

    Science.gov (United States)

    Suzuki, Motofumi; Itoh, Tadayoshi; Taga, Yasunori

    1999-06-01

    More than 10 years ago, birefringent films of metal oxides were formed by oblique vapor deposition and investigated with a view of their application to optical retardation plates. The retardation function of the films was explained in terms of the birefringence caused by the characteristic anisotropic nanostructure inside the films. These films are now classified in the genre of the so-called sculptured thin films. However, the birefringent films thus prepared are not yet industrialized even now due to the crucial lack of the durability and the yield of products. In this review paper, we describe the present status of application process of the retardation films to the information systems such as compact disc and digital versatile disc devices with a special emphasis on the uniformity of retardation properties in a large area and the stability of the optical properties of the obliquely deposited thin films. Finally, further challenges for wide application of the obliquely deposited thin films are also discussed.

  14. Asteroseismic Determination of Obliquities of the Exoplanet Systems Kepler-50 and Kepler-65

    NARCIS (Netherlands)

    Chaplin, W.J.; Sanchis-Ojeda, R.; Campante, T.L.; Handberg, R.; Stello, D.; Winn, J.N.; Basu, S.; Christensen-Dalsgaard, J.; Davies, G.R.; Metcalfe, T.S.; Buchhave, L.A.; Fischer, D.A.; Bedding, T.R.; Cochran, W.D.; Elsworth, Y.; Gilliland, R.L.; Hekker, S.; Huber, D.; Isaacson, H.; Karoff, C.; Kawaler, S.D.; Kjeldsen, H.; Latham, D.W.; Lund, M.N.; Lundkvist, M.; Marcy, G.W.; Miglio, A.; Barclay, T.; Lissauer, J.J.

    2013-01-01

    Results on the obliquity of exoplanet host stars?the angle between the stellar spin axis and the planetary orbital axis?provide important diagnostic information for theories describing planetary formation. Here we present the first application of asteroseismology to the problem of stellar obliquity

  15. Compressive failure model for fiber composites by kink band initiation from obliquely aligned, shear-dislocated fiber breaks

    Energy Technology Data Exchange (ETDEWEB)

    Bai, J.; Phoenix, S.L. [Cornell University, Ithaca, NY (United States). Dept. of Theoretical and Applied Mechanics

    2005-04-01

    Predicting compressive failure of a unidirectional fibrous composite is a longstanding and challenging problem that we study from a new perspective. Motivated by previous modelling of tensile failure as well as experimental observations on compressive failures in single carbon fibers, we develop a new micromechanical model for the compressive failure process in unidirectional, planar composites. As the compressive load is increased, random fiber failures are assumed to occur due to statistically distributed flaws, analogous to what occurs in tension. These breaks are often shear-mode failures with slanted surfaces that induce shear dislocations, especially when they occur in small groups aligned obliquely. Our model includes interactions of dislocated and neighboring intact fibers through a system of fourth-order, differential equations governing transverse deformation, and also allows for local matrix plastic yielding and debonding from the fiber near and within the dislocation arrays. Using the Discrete Fourier Transform method, we find a 'building-block' analytical solution form, which naturally embodies local length scales of fiber microbuckling and instability. Based on the influence function, superposition approach, a computationally efficient scheme is developed to model the evolution of fiber and matrix stresses. Under increasing compressive strain the simulations show that matrix yielding and debonding crucially lead to large increases in bending strains in fibers next to small groups of obliquely aligned, dislocated breaks. From the paired locations of maximum fiber bending in flanking fibers, the triggering of an unstable kink band becomes realistic. The geometric features of the kink band, such as the fragment lengths and orientation angles, will depend on the fiber and matrix mechanical and geometric properties. In carbon fiber-polymer matrix systems our model predicts a much lower compressive failure stress than obtained from Rosen

  16. The oblique occipital sinus: anatomical study using bone subtraction 3D CT venography.

    Science.gov (United States)

    Shin, Hwa Seon; Choi, Dae Seob; Baek, Hye Jin; Choi, Ho Cheol; Choi, Hye Young; Park, Mi Jung; Kim, Ji Eun; Han, Jeong Yeol; Park, SungEun

    2017-06-01

    An occipital sinus draining into the sigmoid sinus has been termed the oblique occipital sinus (OOS). The frequency, anatomical features, patterns, and relationship with the transverse sinus of the oblique occipital sinus were analyzed in this study. The study included 1805 patients who underwent brain CT angiography during a 3-year period from 2013 to 2015. CT examinations were performed using a 64-slice MDCT system. The OOS was identified in 41 patients (2.3%). There were many anatomical variations in the oblique occipital sinuses. A hypoplastic or aplastic TS was seen in 31 (75.6%) of the 41 patients with OOS. Many anatomical variations in the oblique occipital sinus can be seen on CT venography. Some OOSs function as the main drainage route of the intracranial veins instead of the TS. Thus, careful examination is essential for preoperative evaluation in posterior fossa lesions.

  17. Modeling the planar configuration of extraordinary magnetoresistance

    International Nuclear Information System (INIS)

    El-Ahmar, S; Pozniak, A A

    2015-01-01

    Recently the planar version of the extraordinary magnetoresistance (EMR) magnetic field sensor has been constructed and verified in practice. Planar configuration of the EMR device gives many technological advantages, it is simpler than the classic and allows one to build the sensor using electric materials of the new type (such as graphene or topological insulators) much easier. In this work the planar configuration of the EMR sensor is investigated by performing computational simulations using the finite element method (FEM). The computational comparison of the planar and classic configurations of EMR is presented using three-dimensional models. Various variants of the geometry of EMR sensor components are pondered and compared in the planar and classic version. Size of the metal overlap is considered for sensor optimization as well as various semiconductor-metal contact resistance dependences of the EMR signal. Based on computational simulations, a method for optimal placement of electric terminals in a planar EMR device is proposed. (paper)

  18. Adhesion mechanism of a gecko-inspired oblique structure with an adhesive tip for asymmetric detachment

    International Nuclear Information System (INIS)

    Sekiguchi, Yu; Sato, Chiaki; Takahashi, Kunio

    2015-01-01

    An adhesion model of an oblique structure with an adhesive tip is proposed by considering a limiting stress for adhesion to describe the detachment mechanism of gecko foot hairs. When a force is applied to the root of the oblique structure, normal and shear stresses are generated at contact and the adhesive tip is detached from the surface when reaching the limiting stress. An adhesion criterion that considers both the normal and shear stresses is introduced, and the asymmetric detachment of the oblique structure is theoretically investigated. In addition, oblique beam array structures are manufactured, and an inclination effect of the structure on the asymmetric detachment is experimentally verified. (paper)

  19. Contracting a planar graph efficiently

    DEFF Research Database (Denmark)

    Holm, Jacob; Italiano, Giuseppe F.; Karczmarz, Adam

    2017-01-01

    the data structure, we can achieve optimal running times for decremental bridge detection, 2-edge connectivity, maximal 3-edge connected components, and the problem of finding a unique perfect matching for a static planar graph. Furthermore, we improve the running times of algorithms for several planar...

  20. Inkjet-based adaptive planarization (Conference Presentation)

    Science.gov (United States)

    Singhal, Shrawan; Grigas, Michelle M.; Khusnatdinov, Niyaz; Sreenivasan, Srinivasan V.

    2017-03-01

    Planarization is a critical unit step in the lithography process because it enables patterning of surfaces with versatile pattern density without compromising on the stringent planarity and depth-of-focus requirements. In addition to nanoscale pattern density variation, parasitics such as pre-existing wafer topography, can corrupt the desired process output after planarization. The topography of any surface can be classified in three broad categories, depending upon the amplitude and spatial wavelength of the same [1], [2]: (i) nominal shape, (ii) nanotopography and (iii) roughness. The nominal shape is given by the largest spatial wavelengths, typically back is one technique used for micron scale device manufacturing [3]. As the name implies, a glass dielectric is spin-coated on the substrate followed by etching in a chemistry that ensures equal etching rates for both the sacrificial glass and the underlying film or substrate material. Photoresists may also be used instead of glass. However, the global planarity that can be achieved by this technique is limited. Also, planarization over a large isolated topographical feature has been studied for the reverse-tone Jet-and-Flash Imprint Lithography process, also known as JFIL-R [4]. This relies on surface tension and capillary effects to smoothen a spin-coated Si containing film that can be etched to obtain a smooth profile. To meet the stringent requirement of planarity in submicron device technologies Chemical Mechanical Planarization (CMP) is the most widely used planarization technology [5], [6]. It uses a combination of abrasive laden chemical slurry and a mechanical pad for achieving planar profiles. The biggest concern with CMP is the dependence of material removal rate on the pattern density of material, leading to the formation of a step between the high density and low-density. The step shows up as a long-range thickness variation in the planarized film, similar in scale to pre-existing substrate topography

  1. The non-aligned pulsar magnetosphere: an illustrative model for small obliquity

    International Nuclear Information System (INIS)

    Mestel, L.; Wang, Y.M.

    1982-01-01

    The electromagnetic field outside a pulsar of small obliquity is approximated by Goldreich-Julian (GJ) conditions out to the light-cylinder and by an outgoing vacuum wave beyond, matched by the appropriate surface charge-current distribution. The energy supply for the wave requires current flow between the pulsar and the light-cylinder. As in the earlier proposal for the aligned rotator, the cold electrons carrying the current achieve relativistic energies near the light-cylinder; the consequent inertial and radiation damping forces enable the electrons to drift across the field-lines and so complete their circuits back to the pulsar. It is hypothesized that low-obliquity pulsars are essentially emitters of a plasma-modified low-frequency wave and of gamma-radiation near the light-cylinder. Illustrative models are constructed as perturbations about an analogous approximate model for the aligned case. The precessional torque component accompanying the braking component acts so as to reduce the obliquity. As long as the obliquity is not too large there is no prima facie objection to non-relativistic flow near the star. It is emphasized that fully self-consistent models will have a smooth rather than a sharp transition between the GJ and vacuum domains. (author)

  2. Double oblique MR images of the shoulder. Comparison with conventional images

    International Nuclear Information System (INIS)

    Sasaki, Taisuke; Saito, Yoko; Yodono, Hiraku; Miura, Hiroyuki; Shinohara, Atsushi; Abe, Shuichiro

    1998-01-01

    Because the scapula is not only slanted on transverse sections but also inclines on sagittal sections, we now perform shoulder MR imaging using double oblique images (DOI), which are planes perpendicular or parallel to the long axis of the scapula obtained with oblique sagittal scout imaging. The purpose of this study was to evaluate the usefulness of double oblique shoulder MR imaging. MR images of shoulders with operatively or arthroscopically proven lesions (20 cases) that had been examined on both conventional images (CI) and DOI were retrospectively reviewed. DOI were compared with CI not only in terms of diagnostic performance but also in their ability to identify the details of shoulder anatomy. All MR studies were done with a shoulder coil on a high-field (1.5 T) unit. Although the accuracy of DOI in diagnosing shoulder disorders such as rotator cuff tear and labrum injury was not as good as that of CI, DOI were better for identifying or discriminating muscles and tendons of the rotator cuff, labralbicipital junction and anterior band of the inferior gleno-humeral ligament, and for recognizing the correct position of the glenoid labrum. MR double oblique imaging of the shoulder provides more detailed information about shoulder anatomy and disorders than conventional imaging. (author)

  3. Are oblique views necessary for detecting space occupying lesions in liver scintigraphy

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Seki, Hiroyasu; Taki, Junichi; Yokoyama, Kunihiko; Tada, Akira

    1983-01-01

    In colloid scanning of the liver to determine the presence or absence of SOL(s), it has been suggested that oblique views are desirable. However, it is not popular in Japan to obtain oblique views in routine liver imgaing. The present study was conducted to determine whether such additional views are necessary or not. Liver images of 20 patients with SOL(s) and 84 patients without SOL, all of which were confirmed by ultrasonography, transmission computed tomography and/or clinical course, were evaluated initially using 4 standard views and then adding oblique views by 6 physicians (3 experts and 3 freshmen in nuclear medicine). The numbers of cases showing different interpretation between 4 views and 6 views were 15, 10 and 13 each when interpreted by 3 experts. However, those were 21, 33 and 18 each when interpreted by 3 freshmen. Sensitivity for detecting SOL was improved in 3 physicians by adding oblique views, but was the same in other 3. Specificity was improved in only one physicinan. Overall accuracy was consequently improved in 4 physicians and was deteriorated in 2 physicians. ROC analysis revealed that in the freshman group more accurate interpretation was attained by using 6 views, but in the expert group false-positive cases were increased by using 6 views. Some cases showing usefulness for detecting SOL were presented. In conclusion, oblique views gave more accurate interpretation in inexpertienced observers, and useful information in some cases. (author)

  4. Activities of the Vastus Lateralis and Vastus Medialis Oblique Muscles during Squats on Different Surfaces.

    Science.gov (United States)

    Hyong, In Hyouk; Kang, Jong Ho

    2013-08-01

    [Purpose] The purpose of the present study was to examine the effects of squat exercises performed on different surfaces on the activity of the quadriceps femoris muscle in order to provide information on support surfaces for effective squat exercises. [Subjects and Method] Fourteen healthy subjects performed squat exercises for five seconds each on three different support surfaces: hard plates, foam, and rubber air discs. Their performance was measured using electromyography. As the subjects performed the squat exercises on each surface, data on the activity of the vastus medialis oblique and the vastus lateralis, and the vastus medials oblique/vastus lateralis ratio, were collected. [Results] The activity of the vastus medialis oblique and the vastus medialis oblique/vastus lateralis ratio were found to be statistically significantly higher on rubber air discs than when the squats were performed on hard plates or foam. [Conclusion] To activate the vastus medialis obilique, and to enhance the vastus medialis oblique/vastus lateralis ratio, unstable surfaces that are highly unstable should be selected.

  5. Stereotactic biopsy of cerebellar lesions: straight versus oblique frame positioning.

    Science.gov (United States)

    Quick-Weller, Johanna; Brawanski, Nina; Dinc, Nazife; Behmanesh, Bedjahn; Kammerer, Sara; Dubinski, Daniel; Seifert, Volker; Marquardt, Gerhard; Weise, Lutz

    2017-10-26

    Biospies of brain lesions with unknown entity are an everyday procedure among many neurosurgical departments. Biopsies can be performed frame-guided or frameless. However, cerebellar lesions are a special entity with a more complex approach. All biopsies in this study were performed stereotactically frame guided. Therefore, only biopsies of cerebellar lesions were included in this study. We compared whether the frame was attached straight versus oblique and we focused on diagnostic yield and complication rate. We evaluated 20 patients who underwent the procedure between 2009 and 2017. Median age was 56.5 years. 12 (60%) Patients showed a left sided lesion, 6 (30%) showed a lesion in the right cerebellum and 2 (10%) patients showed a midline lesion. The stereotactic frame was mounted oblique in 12 (60%) patients and straight in 8 (40%) patients. Postoperative CT scan showed small, clinically silent blood collection in two (10%) of the patients, one (5%) patient showed haemorrhage, which caused a hydrocephalus. He received an external ventricular drain. In both patients with small haemorrhage the frame was positioned straight, while in the patient who showed a larger haemorrhage the frame was mounted oblique. In all patients a final histopathological diagnosis was established. Cerebellar lesions of unknown entity can be accessed transcerebellar either with the stereotactic frame mounted straight or oblique. Also for cerebellar lesions the procedure shows a high diagnostic yield with a low rate of severe complications, which need further treatment.

  6. Piecewise planar Möbius bands

    DEFF Research Database (Denmark)

    Gravesen, Jens

    2005-01-01

    t is shown that a closed polygon with an odd number of vertices is the median of exactly one piecewise planar cylinder and one piecewise planar Möbius band, intersecting each other orthogonally. A closed polygon with an even number of vertices is in the generic case neither the median...

  7. Cost-effectiveness of preoperative SPECT/CT combined with lymphoscintigraphy vs. lymphoscintigraphy for sentinel lymph node excision in patients with cutaneous malignant melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Stoffels, Ingo; Leyh, Julia; Schadendorf, Dirk; Klode, Joachim [University of Duisburg-Essen, Department of Dermatology, Venerology and Allergology, University-Hospital Essen, Essen (Germany); Mueller, Markus [University of Duisburg-Essen, Department of Medical controlling, University-Hospital Essen, Essen (Germany); Geisel, Marie Henrike [University of Duisburg-Essen, Institute for Medical Informatics, Biometry and Epidemiology, University-Hospital Essen, Essen (Germany); Poeppel, Thorsten [University of Duisburg-Essen, Department of Nuclear Medicine, University-Hospital Essen, Essen (Germany)

    2014-09-15

    Malignant melanoma has become a major growing interdisciplinary problem in public health worldwide. Sentinel lymph node excision (SLNE) in conjunction with preoperative SPECT/CT is considered the most sensitive and specific staging test for the detection of micrometastatic melanoma in regional lymph nodes. Among patients with clinically lymph node-negative melanoma, the use of SPECT/CT-aided SLNE compared with SLNE alone has been found to be associated with a higher frequency of metastatic involvement and a higher rate of disease-free survival. The aim of this study was to analyse the cost-effectiveness of SLNE with preoperative SPECT/CT for detecting sentinel lymph nodes versus that of standard SLNE with preoperative lymphoscintigraphy from a single-institution database. Cost-effectiveness analysis of two surgical approaches for SLNE for malignant melanoma at the University Hospital Essen, Skin Cancer Center in Essen, Germany. Between March 2003 and April 2011 464 patients eligible for SLNE were identified. Of these patients, 403 with clinically negative lymph nodes who underwent SLNE with or without preoperative SPECT/CT qualified for subsequent analysis. Between March 2003 and October 2008, 254 patients were operated upon with the standard technique. From November 2008, 149 patients underwent the SPECT/CT technique. Cost analysis showed a mean cost saving of EUR 710.50 when SPECT/CT was added to preoperative imaging. This was achieved by a reduction in operative time (median, Q1;Q3, 40 min, 40;50 min, vs. 45 min, 35;60 min; p = 0.002), hospital stay duration (5 days, 3;8 days, vs. 8 days, 4.5;14.5 days; p < 0.001) and more frequent use of local anaesthesia (90.6 % vs. 70.5 %; p < 0.001). The median cost of SLNE using SPECT/CT was EUR 1,619.7 (Q1;Q3 EUR 1,317.0;2,603.4) and of SLNE without SPECT/CT was EUR 2,330.2 (EUR 1,468.3;4,058.1; p < 0.001), a cost saving of 30.5 %. In patients with cutaneous melanoma, the use of preoperative SPECT/CT-aided SLNE compared

  8. Improved Dynamic Planar Point Location

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Arge, Lars; Georgiadis, Loukas

    2006-01-01

    We develop the first linear-space data structures for dynamic planar point location in general subdivisions that achieve logarithmic query time and poly-logarithmic update time.......We develop the first linear-space data structures for dynamic planar point location in general subdivisions that achieve logarithmic query time and poly-logarithmic update time....

  9. Planar impact experiments for EOS measurements

    International Nuclear Information System (INIS)

    Furnish, M.D.

    1993-01-01

    The community concerned with the numerical modeling of groundshock produced by underground nuclear tests must have access to materials data to benchmark models of rock behavior. Historically the primary source of these data has been planar impact experiments. These experiments have involved gun, explosive and electrical launchers. Other methods of introducing planar shocks include shock driving by in-contact explosives or laser bursts. This paper briefly describes gun launcher-based planar impact methods used to characterize geological materials at Sandia National Laboratories

  10. A Second Radioisotope Injection Enhances Intraoperative Sentinel Node Identification in Breast Cancer Patients without Visualized Nodes on Preoperative Lymphoscintigraphy

    International Nuclear Information System (INIS)

    Leikola, J.P.; Leppaenen, E.A.; Smitten, K.A.J. von; Leidenius, M.H.K

    2006-01-01

    Purpose: To evaluate the influence of a second radioisotope injection on the intraoperative success rate in patients with non-visualized axillary sentinel nodes (SN). Material and Methods: Altogether, 534 consecutive breast cancer patients with lymphoscintigraphy (LS) and SN biopsy and were included. An intratumoral injection of 99m Tc-labeled human albumin colloid with a median dose of 93 MBq was applied. Forty-two of the 80 patients without axillary hot spots on LS received a second tracer injection with a median dose of 70 MBq. Results: The visualization rate of axillary SN was 454/534 (85%). The intraoperative SN identification rate was 97% in patients with and 69% in patients without visualized SN in the axilla ( P <0.00005), but the success rate was higher (88%) with a second radioisotope injection than without it (47%; P <0.0002). Conclusion: The failure rate in intraoperative SN identification was minimized using a second radioisotope injection in patients without axillary SN on LS

  11. ACCURACY ANALYSIS FOR AUTOMATIC ORIENTATION OF A TUMBLING OBLIQUE VIEWING SENSOR SYSTEM

    Directory of Open Access Journals (Sweden)

    K. Stebner

    2014-03-01

    Full Text Available Dynamic camera systems with moving parts are difficult to handle in photogrammetric workflow, because it is not ensured that the dynamics are constant over the recording period. Minimum changes of the camera’s orientation greatly influence the projection of oblique images. In this publication these effects – originating from the kinematic chain of a dynamic camera system – are analysed and validated. A member of the Modular Airborne Camera System family – MACS-TumbleCam – consisting of a vertical viewing and a tumbling oblique camera was used for this investigation. Focus is on dynamic geometric modeling and the stability of the kinematic chain. To validate the experimental findings, the determined parameters are applied to the exterior orientation of an actual aerial image acquisition campaign using MACS-TumbleCam. The quality of the parameters is sufficient for direct georeferencing of oblique image data from the orientation information of a synchronously captured vertical image dataset. Relative accuracy for the oblique data set ranges from 1.5 pixels when using all images of the image block to 0.3 pixels when using only adjacent images.

  12. Contact planarization of ensemble nanowires

    Science.gov (United States)

    Chia, A. C. E.; LaPierre, R. R.

    2011-06-01

    The viability of four organic polymers (S1808, SC200, SU8 and Cyclotene) as filling materials to achieve planarization of ensemble nanowire arrays is reported. Analysis of the porosity, surface roughness and thermal stability of each filling material was performed. Sonication was used as an effective method to remove the tops of the nanowires (NWs) to achieve complete planarization. Ensemble nanowire devices were fully fabricated and I-V measurements confirmed that Cyclotene effectively planarizes the NWs while still serving the role as an insulating layer between the top and bottom contacts. These processes and analysis can be easily implemented into future characterization and fabrication of ensemble NWs for optoelectronic device applications.

  13. Quality control on planar n-in-n pixel sensors — Recent progress of ATLAS planar pixel sensors

    International Nuclear Information System (INIS)

    Klingenberg, R.

    2013-01-01

    To extend the physics reach of the Large Hadron Collider (LHC), upgrades to the accelerator are planned which will increase the peak luminosity by a factor 5–10. To cope with the increased occupancy and radiation damage, the ATLAS experiment plans to introduce an all-silicon inner tracker with the high luminosity upgrade (HL-LHC). To investigate the suitability of pixel sensors using the proven planar technology for the upgraded tracker, the ATLAS Upgrade Planar Pixel Sensor (PPS) R and D Project was established. Main areas of research are the performance of planar pixel sensors at highest fluences, the exploration of possibilities for cost reduction to enable the instrumentation of large areas, the achievement of slim or active edges to provide low geometric inefficiencies without the need for shingling of modules and the investigation of the operation of highly irradiated sensors at low thresholds to increase the efficiency. The Insertable b-layer (IBL) is the first upgrade project within the ATLAS experiment and will employ a new detector layer consisting of silicon pixel sensors, which were improved and prototyped in the framework of the planar pixel sensor R and D project. A special focus of this paper is the status of the development and testing of planar n-in-n pixel sensors including the quality control of the on-going series production and postprocessing of sensor wafers. A high yield of produced planar sensor wafers and FE-I4 double chip sensors after first steps of post-processing including under bump metallization and dicing is observed. -- Highlights: ► Prototypes of irradiated planar n-in-n sensors have been successfully tested under laboratory conditions. ► A quality assurance programme on the series production of planar sensors for the IBL has started. ► A high yield of double chip sensors during the series production is observed which are compatible to the specifications to this detector component.

  14. Magnetization reversal mechanisms under oblique magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Ntallis, N.; Efthimiadis, K.G., E-mail: kge@auth.gr

    2017-03-01

    In this work finite element micromagnetic simulations were performed in order to study the reversal mechanisms of spherical ferromagnetic particles with uniaxial magnetocrystalline anisotropy, when they are magnetized along an oblique direction with respect to the anisotropy axis. Magnetization loops are taken in different directions of external magnetic field, at different anisotropy constants and particle sizes. In the simulation results, the three reversal mechanisms (coherent, curling and domains) are observed and new phenomena arise due to the action of oblique magnetic fields. Moreover, the dependence of the critical fields with respect to the angle of the external field is presented. - Highlights: • Finite element micromagnetic simulation of the three different reversal mechanisms. • For the curling mechanism, the new phenomenon is the rotation of the vortex. • In the domain reversal mechanism, the formed domain wall is smaller than 180°. • In soft ferromagnetic particles a rearrangement of the magnetic domains is observed.

  15. Oblique whistler instability in the earth's foreshock

    International Nuclear Information System (INIS)

    Sentman, D.D.; Thomsen, M.F.; Gary, S.P.; Feldman, W.C.; Hoppe, M.M.

    1983-01-01

    The linear Vlasov stability properties of electron velocity distributions, similar to those observed in the upstream foreshock region in association with obliquely propagating whistler waves at approximately 1 Hz, are studied. These distributions are modeled by a sum of bi-Maxwellians with drift speeds parallel to the magnetic field B. We find such distributions to be stable to modes with wavevectors k parallel to B but unstable to whistler waves propagating obliquely to the magnetic field. The frequencies and wavelengths of these unstable modes agree well with those of whistlers observed upstream of the earth's bow shock. The free energy source driving the instability is a region of positive parallel slope partialf/sub e//partialv/sub parallel/>0 at large pitch angles (about 85 0 ) and intermediate energies (about 20 eV), probably corresponding to the solar wind electrons magnetostatically reflected from the magnetic ramp of the bow shock. The whistlers grow via electromagnetic Landau resonance with this free energy source

  16. Ice Caps and Ice Belts: The Effects of Obliquity on Ice−Albedo Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Rose, Brian E. J. [Department of Atmospheric and Environmental Sciences, University at Albany (State University of New York), 1400 Washington Avenue, Albany, NY 12222 (United States); Cronin, Timothy W. [Program in Atmospheres, Oceans, and Climate, Massachusetts Institute of Technology 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Bitz, Cecilia M., E-mail: brose@albany.edu [Department of Atmospheric Sciences, MS 351640, University of Washington, Seattle, WA 98195-1640 (United States)

    2017-09-01

    Planetary obliquity determines the meridional distribution of the annual mean insolation. For obliquity exceeding 55°, the weakest insolation occurs at the equator. Stable partial snow and ice cover on such a planet would be in the form of a belt about the equator rather than polar caps. An analytical model of planetary climate is used to investigate the stability of ice caps and ice belts over the widest possible range of parameters. The model is a non-dimensional diffusive Energy Balance Model, representing insolation, heat transport, and ice−albedo feedback on a spherical planet. A complete analytical solution for any obliquity is given and validated against numerical solutions of a seasonal model in the “deep-water” regime of weak seasonal ice line migration. Multiple equilibria and unstable transitions between climate states (ice-free, Snowball, or ice cap/belt) are found over wide swaths of parameter space, including a “Large Ice-Belt Instability” and “Small Ice-Belt Instability” at high obliquity. The Snowball catastrophe is avoided at weak radiative forcing in two different scenarios: weak albedo feedback and inefficient heat transport (favoring stable partial ice cover), or efficient transport at high obliquity (favoring ice-free conditions). From speculative assumptions about distributions of planetary parameters, three-fourths to four-fifths of all planets with stable partial ice cover should be in the form of Earth-like polar caps.

  17. 3D MODEL GENERATION USING OBLIQUE IMAGES ACQUIRED BY UAV

    Directory of Open Access Journals (Sweden)

    A. Lingua

    2017-07-01

    Full Text Available In recent years, many studies revealed the advantages of using airborne oblique images for obtaining improved 3D city models (including façades and building footprints. Here the acquisition and use of oblique images from a low cost and open source Unmanned Aerial Vehicle (UAV for the 3D high-level-of-detail reconstruction of historical architectures is evaluated. The critical issues of such acquisitions (flight planning strategies, ground control points distribution, etc. are described. Several problems should be considered in the flight planning: best approach to cover the whole object with the minimum time of flight; visibility of vertical structures; occlusions due to the context; acquisition of all the parts of the objects (the closest and the farthest with similar resolution; suitable camera inclination, and so on. In this paper a solution is proposed in order to acquire oblique images with one only flight. The data processing was realized using Structure-from-Motion-based approach for point cloud generation using dense image-matching algorithms implemented in an open source software. The achieved results are analysed considering some check points and some reference LiDAR data. The system was tested for surveying a historical architectonical complex: the “Sacro Mo nte di Varallo Sesia” in north-west of Italy. This study demonstrates that the use of oblique images acquired from a low cost UAV system and processed through an open source software is an effective methodology to survey cultural heritage, characterized by limited accessibility, need for detail and rapidity of the acquisition phase, and often reduced budgets.

  18. A case of dorsal oblique fingertip amputation.

    Science.gov (United States)

    Takeda, Shinsuke; Tatebe, Masahiro; Morita, Akimasa; Yoneda, Hidemasa; Iwatsuki, Katsuyuki; Hirata, Hitoshi

    2017-01-01

    This study reports successful finger replantation in a patient with a dorsal oblique fingertip amputation. When repairing this unique type of injury, an evaluation of the remaining vessels is more useful for successful replantation than the anatomical zone classification. We propose that Kasai's classification is appropriate for guiding treatment.

  19. The Resilience of Kepler Multi-systems to Stellar Obliquity

    Science.gov (United States)

    Spalding, Christopher; Marx, Noah W.; Batygin, Konstantin

    2018-04-01

    The Kepler mission and its successor K2 have brought forth a cascade of transiting planets. Many of these planetary systems exhibit multiple transiting members. However, a large fraction possesses only a single transiting planet. This high abundance of singles, dubbed the "Kepler Dichotomy," has been hypothesized to arise from significant mutual inclinations between orbits in multi-planet systems. Alternatively, the single-transiting population truly possesses no other planets in the system, but the true origin of the overabundance of single systems remains unresolved. In this work, we propose that planetary systems typically form with a coplanar, multiple-planetary architecture, but that quadrupolar gravitational perturbations from their rapidly-rotating host star subsequently disrupt this primordial coplanarity. We demonstrate that, given sufficient stellar obliquity, even systems beginning with 2 planetary constituents are susceptible to dynamical instability soon after planet formation, as a result of the stellar quadrupole moment. This mechanism stands as a widespread, yet poorly explored pathway toward planetary system instability. Moreover, by requiring that observed multi-systems remain coplanar on Gyr timescales, we are able to place upper limits on the stellar obliquity in systems such as K2-38 (obliquity < 20 degrees), where other methods of measuring spin-orbit misalignment are not currently available.

  20. Arc Motion in an Obliquely Imposed Alternating Magnetic Field

    International Nuclear Information System (INIS)

    Akiho, R; Takeda, K; Sugimoto, M

    2012-01-01

    The arc motion is theoretically investigated under an alternating magnetic field imposed obliquely to the arc. The arc is known to oscillate on a 2-D plane when the alternating magnetic field is imposed perpendicularly to the arc. If the alternating magnetic field is imposed obliquely to the arc, then it is expected that the arc oscillates not on the 2-D plane but in a 3-D space. For this study, 3-D simulation was performed on the motion of the plasma gas under an alternating magnetic field crossing obliquely to the arc. It was also assumed that a stream line of the plasma gas represented the arc profile. The momentum equation for the plasma gas was solved together with the continuity equation. Governing parameters for the gas motion are θ (crossing angle), v 0 (initial velocity of the plasma gas), and λ. Parameter λ is defined as λ = (I a B 0 )/Q 0 . Numerical results are reported under different operating conditions such as magnetic flux densities and the angles between the arc and the magnetic flux. If the crossing angle is larger than 4/π, the arc might be extinguished because of the drastic increase of the arc length.

  1. Three-dimensional oblique water-entry problems at small deadrise angles

    KAUST Repository

    Moore, M. R.

    2012-09-19

    This paper extends Wagner theory for the ideal, incompressible normal impact of rigid bodies that are nearly parallel to the surface of a liquid half-space. The impactors considered are three-dimensional and have an oblique impact velocity. A formulation in terms of the displacement potential is used to reveal the relationship between the oblique and corresponding normal impact solutions. In the case of axisymmetric impactors, several geometries are considered in which singularities develop in the boundary of the effective wetted region. We present the corresponding pressure profiles and models for the splash sheets. © 2012 Cambridge University Press.

  2. Three-dimensional oblique water-entry problems at small deadrise angles

    KAUST Repository

    Moore, M. R.; Howison, S. D.; Ockendon, J. R.; Oliver, J. M.

    2012-01-01

    This paper extends Wagner theory for the ideal, incompressible normal impact of rigid bodies that are nearly parallel to the surface of a liquid half-space. The impactors considered are three-dimensional and have an oblique impact velocity. A formulation in terms of the displacement potential is used to reveal the relationship between the oblique and corresponding normal impact solutions. In the case of axisymmetric impactors, several geometries are considered in which singularities develop in the boundary of the effective wetted region. We present the corresponding pressure profiles and models for the splash sheets. © 2012 Cambridge University Press.

  3. Obliquely propagating cnoidal waves in a magnetized dusty plasma with variable dust charge

    International Nuclear Information System (INIS)

    Yadav, L. L.; Sayal, V. K.

    2009-01-01

    We have studied obliquely propagating dust-acoustic nonlinear periodic waves, namely, dust-acoustic cnoidal waves, in a magnetized dusty plasma consisting of electrons, ions, and dust grains with variable dust charge. Using reductive perturbation method and appropriate boundary conditions for nonlinear periodic waves, we have derived Korteweg-de Vries (KdV) equation for the plasma. It is found that the contribution to the dispersion due to the deviation from plasma approximation is dominant for small angles of obliqueness, while for large angles of obliqueness, the dispersion due to magnetic force becomes important. The cnoidal wave solution of the KdV equation is obtained. It is found that the frequency of the cnoidal wave depends on its amplitude. The effects of the magnetic field, the angle of obliqueness, the density of electrons, the dust-charge variation and the ion-temperature on the characteristics of the dust-acoustic cnoidal wave are also discussed. It is found that in the limiting case the cnoidal wave solution reduces to dust-acoustic soliton solution.

  4. Teetering Stars: Resonant Excitation of Stellar Obliquities by Hot and Warm Jupiters with External Companions

    Science.gov (United States)

    Anderson, Kassandra; Lai, Dong

    2018-04-01

    Stellar spin-orbit misalignments (obliquities) in hot Jupiter systems have been extensively probed in recent years thanks to Rossiter-McLaughlin observations. Such obliquities may reveal clues about hot Jupiter dynamical and migration histories. Common explanations for generating stellar obliquities include high-eccentricity migration, or primordial disk misalignment. This talk investigates another mechanism for producing stellar spin-orbit misalignments in systems hosting a close-in giant planet with an external, inclined planetary companion. Spin-orbit misalignment may be excited due to a secular resonance, occurring when the precession rate of the stellar spin axis (due to the inner orbit) becomes comparable to the precession rate of the inner orbital axis (due to the outer companion). Due to the spin-down of the host star via magnetic braking, this resonance may be achieved at some point during the star's main sequence lifetime for a wide range of giant planet masses and orbital architectures. We focus on both hot Jupiters (with orbital periods less than ten days) and warm Jupiters (with orbital periods around tens of days), and identify the outer perburber properties needed to generate substantial obliquities via resonant excitation, in terms of mass, separation, and inclination. For hot Jupiters, the stellar spin axis is strongly coupled to the orbital axis, and resonant excitation of obliquity requires a close perturber, located within 1-2 AU. For warm Jupiters, the spin and orbital axes are more weakly coupled, and the resonance may be achieved for more distant perturbers (at several to tens of AU). Resonant excitation of the stellar obliquity is accompanied by a decrease in the planets' mutual orbital inclination, and can thus erase high mutual inclinations in two-planet systems. Since many warm Jupiters are known to have outer planetary companions at several AU or beyond, stellar obliquities in warm Jupiter systems may be common, regardless of the

  5. Lymphoscintigraphy and radioguided surgery in cervical and vulvar malignant tumours

    International Nuclear Information System (INIS)

    Morales Guzman-Barron, Rosanna E.

    2006-01-01

    Objective: To validate a combined technique in the detection of sentinel nodes in early cervix and vulvar cancer patients. Material and Methods: Seventy patients, 24 to 63 years old (average 40 years), with cervical cancer stages IA2, IB1 and IIA, and fourteen patients, 28 to 80 years old (median 68 years) with vulval neoplasm, stage I and II, had sentinel node (SN) detection using lymphoscintigraphy and a gamma probe in the surgical room, after injection of Tc 99m dextran and patent blue dye. Sentinel nodes were seen between 20 and 135 minutes after injection, in cervical cancer, and between one and sixty minutes in vulvar neoplasms. In patients with cervical tumors, 99 sentinel nodes were localized in the obturator region, 28 were interiliac, nine were located in the external iliac region, three in the common iliac region and one was found in perineum. In patients with a vulvar neoplasm, all sentinel nodes were located in the superficial inguinal region. The detection rate was 98,8% for cervical cancer and 100% for vulvar neoplasms, with bilateral drainage in 46% and 29% respectively. Metastases were found in 10,4% (7/65) of IB1 stage cervical cancer patients (6 squamous cell carcinomas - non keratinizing: 5, keratinizing: 1 and one adenocarcionoma) and none in four patients with IA2 stage (with non keratinizing squamous cell carcinoma). The patients with IIA stage cervical cancer (keratinizing squamous cell carcinoma) had metastases in the SN. Three out of 14 patients with vulvar cancer showed metastases in the sentinel node. Two of them had epidermoid carcinoma and one, malignant melanoma. There were no metastases in non-sentinel nodes when sentinel nodes were negative for metastases, both in cervical or vulvar cancer. Conclusion: It is feasible to localize sentinel nodes in cervical and vulvar cancer, using a combined technique with Tc 99m Dextran and 'patent blue'. (author)

  6. A case of dorsal oblique fingertip amputation

    OpenAIRE

    Takeda, Shinsuke; Tatebe, Masahiro; Morita, Akimasa; Yoneda, Hidemasa; Iwatsuki, Katsuyuki; Hirata, Hitoshi

    2017-01-01

    Abstract This study reports successful finger replantation in a patient with a dorsal oblique fingertip amputation. When repairing this unique type of injury, an evaluation of the remaining vessels is more useful for successful replantation than the anatomical zone classification. We propose that Kasai?s classification is appropriate for guiding treatment.

  7. Modified planar functions and their components

    DEFF Research Database (Denmark)

    Anbar Meidl, Nurdagül; Meidl, Wilfried Meidl

    2017-01-01

    functions in odd characteristic as a vectorial bent function. We finally point out that though these components behave somewhat different than the multivariate bent4 functions, they are bent or semibent functions shifted by a certain quadratic term, a property which they share with their multivariate......Zhou ([20]) introduced modified planar functions in order to describe (2n; 2n; 2n; 1) relative difference sets R as a graph of a function on the finite field F2n, and pointed out that projections of R are difference sets that can be described by negabent or bent4 functions, which are Boolean...... functions given in multivariate form. One of the objectives of this paper is to contribute to the understanding of these component functions of modified planar functions. Moreover, we obtain a description of modified planar functions by their components which is similar to that of the classical planar...

  8. Combining evolutionary algorithms with oblique decision trees to detect bent-double galaxies

    Science.gov (United States)

    Cantu-Paz, Erick; Kamath, Chandrika

    2000-10-01

    Decision tress have long been popular in classification as they use simple and easy-to-understand tests at each node. Most variants of decision trees test a single attribute at a node, leading to axis- parallel trees, where the test results in a hyperplane which is parallel to one of the dimensions in the attribute space. These trees can be rather large and inaccurate in cases where the concept to be learned is best approximated by oblique hyperplanes. In such cases, it may be more appropriate to use an oblique decision tree, where the decision at each node is a linear combination of the attributes. Oblique decision trees have not gained wide popularity in part due to the complexity of constructing good oblique splits and the tendency of existing splitting algorithms to get stuck in local minima. Several alternatives have been proposed to handle these problems including randomization in conjunction wiht deterministic hill-climbing and the use of simulated annealing. In this paper, we use evolutionary algorithms (EAs) to determine the split. EAs are well suited for this problem because of their global search properties, their tolerance to noisy fitness evaluations, and their scalability to large dimensional search spaces. We demonstrate our technique on a synthetic data set, and then we apply it to a practical problem from astronomy, namely, the classification of galaxies with a bent-double morphology. In addition, we describe our experiences with several split evaluation criteria. Our results suggest that, in some cases, the evolutionary approach is faster and more accurate than existing oblique decision tree algorithms. However, for our astronomical data, the accuracy is not significantly different than the axis-parallel trees.

  9. A numerical simulation of climate changes during the obliquity cycle on Mars

    International Nuclear Information System (INIS)

    Francois, L.M.; Walker, J.C.G.; Kuhn, W.R.

    1990-01-01

    A one-dimensional seasonal energy balance climate model has been developed for the Martian surface and coupled to a model of CO 2 distribution between atmosphere, regolith, and polar caps. This model takes into account the greenhouse warming of carbon dioxide, the meridional transport of heat, the CO 2 condensation and sublimation cycle, and its adsorption in the regolith. The model takes into consideration the diurnal variation of solar irradiation, since it is shown that disregard of this effect yields temperatures too high by several degrees. The yearly-averaged temperatures calculated from this climate model at different obliquities are used to estimate the importance of CO 2 exchanges between the regolith and atmosphere-cap systems during the obliquity cycle. For this purpose, the equation of thermal diffusion into the ground is solved for each latitude belt. The results differ substantially from those of previous studies, due in part to the consideration of the diurnal and seasonal variations of the solar irradiance. The model shows the importance of taking these short-period variations into account instead of using yearly-averaged quantities, due to the strong nonlinearity of the climate system on Mars. The roles of meridional heat transport and greenhouse warming are analyzed and shown to be important. For example, a permanent polar cap of carbon dioxide is destroyed by heat transport when the obliquity is high, while at low obliquity, high-pressure systems without permanent cap can exist if enough exchangeable carbon dioxide is available. Further, the results show the possible existence of hysteresis cycles in the formation and sublimation of permanent deposits during the course of the obliquity cycle

  10. Oblique rotaton in canonical correlation analysis reformulated as maximizing the generalized coefficient of determination.

    Science.gov (United States)

    Satomura, Hironori; Adachi, Kohei

    2013-07-01

    To facilitate the interpretation of canonical correlation analysis (CCA) solutions, procedures have been proposed in which CCA solutions are orthogonally rotated to a simple structure. In this paper, we consider oblique rotation for CCA to provide solutions that are much easier to interpret, though only orthogonal rotation is allowed in the existing formulations of CCA. Our task is thus to reformulate CCA so that its solutions have the freedom of oblique rotation. Such a task can be achieved using Yanai's (Jpn. J. Behaviormetrics 1:46-54, 1974; J. Jpn. Stat. Soc. 11:43-53, 1981) generalized coefficient of determination for the objective function to be maximized in CCA. The resulting solutions are proved to include the existing orthogonal ones as special cases and to be rotated obliquely without affecting the objective function value, where ten Berge's (Psychometrika 48:519-523, 1983) theorems on suborthonormal matrices are used. A real data example demonstrates that the proposed oblique rotation can provide simple, easily interpreted CCA solutions.

  11. Orientifold Planar Equivalence: The Chiral Condensate

    DEFF Research Database (Denmark)

    Armoni, Adi; Lucini, Biagio; Patella, Agostino

    2008-01-01

    The recently introduced orientifold planar equivalence is a promising tool for solving non-perturbative problems in QCD. One of the predictions of orientifold planar equivalence is that the chiral condensates of a theory with $N_f$ flavours of Dirac fermions in the symmetric (or antisymmetric...

  12. Overview of Planar Magnetic Technology — Fundamental Properties

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Andersen, Michael A. E.

    2014-01-01

    The momentum towards high efficiency, high frequency, and high power density in power supplies limits wide use of conventional wire-wound magnetic components. This article gives an overview of planar magnetic technologies with respect to the development of modern power electronics. The major...... advantages and disadvantages in the use of planar magnetics for high frequency power converters are covered, and publications on planar magnetics are reviewed. A detailed survey of winding conduction loss, leakage inductance and winding capacitance for planar magnetics is presented so power electronics...

  13. Analysis of variationfor horizontal deviation in the primary position after the inferior oblique muscle weakening

    Directory of Open Access Journals (Sweden)

    Ming-Yu Si

    2015-06-01

    Full Text Available AIM: To analyse the variation of horizontal deviation in the primary position after the inferior oblique muscle weakening, and to explore the effect of the inferior oblique muscle recession on horizontal deviations in primary position.METHODS:, In the study, 30 cases in the Department of ophthalmology of our hospital from January 2014 to September 2014 underwent the inferior oblique muscle recession as the sole without horizontal muscles surgery, who were superior obliquer paralysis and V pattern strabismus with small angle of horizontal strabismus, were analyzed. Of the 30 patients, 25 had unilateral inferior oblique muscle surgery, and then 5 had bilateral surgeries.Followed up for three to six mo, all patients were received full ophthalmologic and orthoptic examinations, including measurement of the deviation in the diagnostic positions of gaze at near 33cm and at distance 6m by prism and alternate cover test, synoptophore, Titmus stereo graph examination, Worth four lighting inspection, eye movement examination, and fundus photography preoperatively and postoperatively. The changes of horizontal deviations in the primary position after procedures were investigated. RESULT:(1The comparison of horizontal deviation showed significant difference pre- and post-operation in the exotropia group(P=0.00. It was postoperative respectively to reduce the original in external oblique average 3.35±2.87△ and 4.37±2.65△.(2The comparison of horizontal deviation showed significant difference pre-and post-operation in the esotropia group(P=0.02, and it decreased postoperatively in average 2.43±1.99△. There was no significant difference for horizontal deviation position between pre- and post-operation(P=0.089. CONCLUSION:The horizontal deviation in primary position, either exotropia or esotropia, will decrease after the Inferior oblique muscle recession. This change can be compensated by the gradually improving and establishing the fusion function.

  14. VASTUS LATERALIS OBLIQUE ACTIVITY DURING GAIT OF SUBJECTS WITH PATELLOFEMORAL PAIN

    Directory of Open Access Journals (Sweden)

    Gilmar Moraes Santos

    Full Text Available ABSTRACT Introduction: So far, little is known about the behavior of electromyographic activity of vastus lateralis oblique muscle during treadmill gait in subjects with and without patellofemoral pain syndrome. Objective: The purpose of this study was to investigate the electromyographic activity of the patellar stabilizers muscles and the angle of the knee joint flexion in subjects with and without patellofemoral pain syndrome. Method: Fifteen subjects without (21 ± 3 years and 12 with patellofemoral pain syndrome (20 ± 2 years were evaluated. The electromyographic activity and flexion angle of the knee joint were obtained during gait on the treadmill with a 5 degree inclination. Results: The knee flexion angle was significantly lower in the subjects with patellofemoral pain syndrome when compared with the healthy controls. The electromyographic activity of vastus lateralis longus was significantly greater during gait on the treadmill with inclination in subjects with patellofemoral pain syndrome. The results also showed that the electromyographic activity of vastus lateralis oblique and vastus medialis oblique were similar in both groups, regardless of the condition (with/without inclination. Conclusion: We have shown that knee kinematics during gait differs among patients with and without patellofemoral pain syndrome and healthy controls and that a different motor strategy persists even when the pain is no longer present. In addition, the findings suggested that the vastus lateralis oblique has a minor role in patellar stability during gait.

  15. Sentinel lymph node detection after transaxillary augmentation mammoplasty: a prospective controlled study utilizing lymphoscintigraphy in 43 breasts

    International Nuclear Information System (INIS)

    Sado, Heitor Naoki; Yamada, Airton Seiji; Graf, Ruth Maria; Timi, Jorge Rufino Ribas; Matias, Jorge Eduardo Fouto; Urban, Cicero Andrade; Woellner, Luiz Carlos; Ferreira, Eduardo de Castro

    2008-01-01

    Objective: To evaluate the potential influence of transaxillary augmentation mammoplasty on future detection of sentinel lymph node. Materials and methods: Prospective controlled study where 22 patients were selected and divided into two groups (post-mammoplasty and control) corresponding to 43 breasts (22 in the post-mammoplasty group and 21 in the control group) evaluated by lymphoscintigraphy immediately after periareolar 99m Tc-phytate injections. In the statistical analysis, p values < 0.05 were considered as significant. Results: All the breasts in the post-mammoplasty group presented lymphatic drainage to the axillary chain, with no difference as compared with the control group (p 0.488). The average number of hot lymph nodes was 1.27 ± 0.46 in the post-mammoplasty group, and 1.33 ± 0.58 in the control group (p = 0.895). The mean time required to visualize the first lymph node was 3.14 ± 4.42 minutes in the post mammoplasty group, and 5.48 ± 5.06 minutes in the control group (p 0.136). Conclusion: Transaxillary augmentation mammoplasty did not affect the future detection of sentinel lymph node. (author)

  16. Nonlinear damping of oblique whistler mode waves through Landau resonance

    Science.gov (United States)

    Hsieh, Y.; Omura, Y.

    2017-12-01

    Nonlinear trapping of electrons through Landau resonance is a characteristic dynamics in oblique whistler-mode wave particle interactions. The resonance velocity of the Landau resonance at quasi-parallel propagation becomes very close to the parallel group velocity of whistler-mode wave at frequency around 0.5 Ωe, causing a long distance of resonant interaction and strong acceleration of resonant electrons [1]. We demonstrate these effective accelerations for electrons with high equatorial pitch angle ( > 60°) by test particle simulations with parameters for the Earth's inner magnetosphere at L=5. In the simulations, we focus on slightly oblique whistler mode waves with wave normal angle 10.1002/2016JA023255.

  17. Application of oblique plane microscopy to high speed live cell imaging

    Science.gov (United States)

    Kumar, Sunil; Wilding, Dean; Sikkel, Markus B.; Lyon, Alexander R.; MacLeod, Ken T.; Dunsby, Chris

    2011-07-01

    Oblique Plane Microscopy (OPM) is a light sheet microscopy technique that combines oblique illumination with correction optics that tilt the focal plane of the collection system. OPM can be used to image conventionally mounted specimens on coverslips or tissue culture dishes and has low out-of-plane photobleaching and phototoxicity. No moving parts are required to achieve an optically sectioned image and so high speed optically sectioned imaging is possible. We present high speed 2D and 3D optically sectioned OPM imaging of live cells using a high NA water immersion lens.

  18. Do oblique views add value in the diagnosis of spondylolysis in adolescents?

    Science.gov (United States)

    Beck, Nicholas A; Miller, Robert; Baldwin, Keith; Zhu, X; Spiegel, David; Drummond, Denis; Sankar, Wudbhav N; Flynn, John M

    2013-05-15

    Anteroposterior, lateral, and right and left oblique lumbar spine radiographs are often a standard part of the evaluation of children who are clinically suspected of having spondylolysis. Recent concerns regarding radiation exposure and costs have brought the value of oblique radiographs into question. The purpose of the present study was to determine the diagnostic value of oblique views in the diagnosis of spondylolysis. Radiographs of fifty adolescents with L5 spondylolysis without spondylolisthesis and fifty controls were retrospectively reviewed. All controls were confirmed not to have spondylolysis on the basis of computed tomographic scanning, magnetic resonance imaging, or bone scanning. Anteroposterior, lateral, and right and left oblique radiographs of the lumbar spine were arranged into two sets of slides: one showing four views (anteroposterior, lateral, right oblique, and left oblique) and one showing two views (anteroposterior and lateral only). The slides were randomly presented to four pediatric spine surgeons for diagnosis, with four-view slides being presented first, followed by two-view slides. The slides for twenty random patients were later reanalyzed in order to calculate of intra-rater agreement. A power analysis demonstrated that this study was adequately powered. Inter-rater and intra-rater agreement were assessed on the basis of the percentage of overall agreement and intraclass correlation coefficients (ICCs). PCXMC software was used to generate effective radiation doses. Study charges were determined from radiology billing data. There was no significant difference in sensitivity and specificity between four-view and two-view radiographs in the diagnosis of spondylolysis. The sensitivity was 0.59 for two-view studies and 0.53 for four-view studies (p = 0.33). The specificity was 0.96 for two-view studies and 0.94 for four-view studies (p = 0.60). Inter-rater agreement, intra-rater agreement, and agreement with gold-standard ICC values

  19. Some remarks on non-planar Feynman diagrams

    International Nuclear Information System (INIS)

    Bielas, Krzysztof; Dubovyk, Ievgen; Gluza, Janusz

    2013-12-01

    Two criteria for planarity of a Feynman diagram upon its propagators (momentum ows) are presented. Instructive Mathematica programs that solve the problem and examples are provided. A simple geometric argument is used to show that while one can planarize non-planar graphs by embedding them on higher-genus surfaces (in the example it is a torus), there is still a problem with defining appropriate dual variables since the corresponding faces of the graph are absorbed by torus generators.

  20. Some remarks on non-planar Feynman diagrams

    Energy Technology Data Exchange (ETDEWEB)

    Bielas, Krzysztof; Dubovyk, Ievgen; Gluza, Janusz [Silesia Univ., Katowice (Poland). Inst. of Physics; Riemann, Tord [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2013-12-15

    Two criteria for planarity of a Feynman diagram upon its propagators (momentum ows) are presented. Instructive Mathematica programs that solve the problem and examples are provided. A simple geometric argument is used to show that while one can planarize non-planar graphs by embedding them on higher-genus surfaces (in the example it is a torus), there is still a problem with defining appropriate dual variables since the corresponding faces of the graph are absorbed by torus generators.

  1. The Resilience of Kepler Systems to Stellar Obliquity

    Science.gov (United States)

    Spalding, Christopher; Marx, Noah W.; Batygin, Konstantin

    2018-04-01

    The Kepler mission and its successor K2 have brought forth a cascade of transiting planets. Many of these planetary systems exhibit multiple members, but a large fraction possess only a single transiting example. This overabundance of singles has led to the suggestion that up to half of Kepler systems might possess significant mutual inclinations between orbits, reducing the transiting number (the so-called “Kepler Dichotomy”). In a recent paper, Spalding & Batygin demonstrated that the quadrupole moment arising from a young, oblate star is capable of misaligning the constituent orbits of a close-in planetary system enough to reduce their transit number, provided that the stellar spin axis is sufficiently misaligned with respect to the planetary orbital plane. Moreover, tightly packed planetary systems were shown to be susceptible to becoming destabilized during this process. Here, we investigate the ubiquity of the stellar obliquity-driven instability within systems with a range of multiplicities. We find that most planetary systems analyzed, including those possessing only two planets, underwent instability for stellar spin periods below ∼3 days and stellar tilts of order 30°. Moreover, we are able to place upper limits on the stellar obliquity in systems such as K2-38 (obliquity ≲20°), where other methods of measuring the spin–orbit misalignment are not currently available. Given the known parameters of T-Tauri stars, we predict that up to one-half of super-Earth-mass systems may encounter the instability, in general agreement with the fraction typically proposed to explain the observed abundance of single-transiting systems.

  2. Planarity certification of ATLAS Micromegas detector panels

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Ralph; Biebel, Otmar; Bortfeldt, Jonathan; Flierl, Bernhard; Hertenberger, Ralf; Loesel, Philipp; Herrmann, Maximilian [LMU Muenchen (Germany); Zibell, Andre [JMU Wuerzburg (Germany)

    2016-07-01

    During the second long LHC shutdown, 2019/20, the precision tracking detectors of the ATLAS muon spectrometer in the inner end caps will be replaced using Micromegas, a planar gas-detector technology. Modules of 2 m{sup 2} area are built in quadruplets from five precisely planar sandwich panels that define the anodes and the cathodes of the four active detector planes. A panel is composed of three consecutive layers FR4 - aluminum honeycomb - FR4. Single plane spatial particle resolution below 100 μm is achievable when the deviations from planarity of the strip-anodes do not exceed 80 μm RMS over the whole active area and the parallelism of the readout strips is within 30 μm. In order to measure the dimensional accuracy of each panel, laser distance sensors combined with a coordinate measurement system have been investigated. The sensor requirements to measure the planarity of the panels are a resolution of 0.3 μm and a beam spot diameter of ∼20 μm, well below 100 μ m the size of the smallest structures. We report on achieved planarities of the panels and the performance of the laser sensor system. A panel with an RMS better than 30 μm was build and the evolution of its planarity due to humidity and temperature effects is shown.

  3. Cervical spine trauma radiographs: Swimmers and supine obliques; an exploration of current practice

    Energy Technology Data Exchange (ETDEWEB)

    Fell, Michael, E-mail: michael.fell@mkgeneral.nhs.u [Milton Keynes General Hospital, Radiology Standing Way, Eaglestone, Milton Keynes, Buckinghamshire MK6 5LD (United Kingdom)

    2011-02-15

    The study objectives were: to investigate current cervical spine radiographic imaging practices in conscious adult patients with suspected neck injury; reasons behind variation and consideration of dose estimates were explored. Comparison with a previous survey has been made. Questionnaires were sent to superintendent radiographers responsible for accident and emergency X-ray departments in English trusts with over 8500 emergency admissions per year, with a response rate of 97% (n = 181/186). Departmental cervical spine imaging protocols were reported by 82% of respondents. None use fewer than the three standard projections; if the cervicothoracic junction (C7/T1), is not adequately demonstrated 87% use swimmers projections, 9% supine obliques, 3% CT alone. Following projectional radiography, 97% perform CT. A significant (p = 0.018) increase was found since 1999 in CT use once the swimmers projection fails; fewer now use obliques at this point, continuing with CT instead. No significant difference (p = 0.644) was found in choice of first supplementary radiographs; despite British Trauma Society's recommendation to undertake supine obliques, swimmers remain the most widespread technique. An 85% response rate (n = 103/121) completed a second questionnaire, exploring reasons behind the various practices. Several reported a perceived difficulty in interpreting oblique radiographs, some a concern over high dose of the swimmers. Numerous issues affect the acquisition of cervical spine radiographs. Patient radiation dose should be a major consideration in selection of technique. A potential need for training in interpretation of obliques is highlighted. Specific guidelines for optimum projections should be researched, and protocols issued to ensure best practice.

  4. Oblique patterned etching of vertical silicon sidewalls

    Science.gov (United States)

    Bruce Burckel, D.; Finnegan, Patrick S.; David Henry, M.; Resnick, Paul J.; Jarecki, Robert L.

    2016-04-01

    A method for patterning on vertical silicon surfaces in high aspect ratio silicon topography is presented. A Faraday cage is used to direct energetic reactive ions obliquely through a patterned suspended membrane positioned over the topography. The technique is capable of forming high-fidelity pattern (100 nm) features, adding an additional fabrication capability to standard top-down fabrication approaches.

  5. Document segmentation via oblique cuts

    Science.gov (United States)

    Svendsen, Jeremy; Branzan-Albu, Alexandra

    2013-01-01

    This paper presents a novel solution for the layout segmentation of graphical elements in Business Intelligence documents. We propose a generalization of the recursive X-Y cut algorithm, which allows for cutting along arbitrary oblique directions. An intermediate processing step consisting of line and solid region removal is also necessary due to presence of decorative elements. The output of the proposed segmentation is a hierarchical structure which allows for the identification of primitives in pie and bar charts. The algorithm was tested on a database composed of charts from business documents. Results are very promising.

  6. Yangian-type symmetries of non-planar leading singularities

    Energy Technology Data Exchange (ETDEWEB)

    Frassek, Rouven [Department of Mathematical Sciences, Durham University,South Road, Durham DH1 3LE (United Kingdom); Meidinger, David [Institut für Mathematik und Institut für Physik, Humboldt-Universität zu Berlin,Zum Großen Windkanal 6, 12489 Berlin (Germany)

    2016-05-18

    We take up the study of integrable structures behind non-planar contributions to scattering amplitudes in N = 4 super Yang-Mills theory. Focusing on leading singularities, we derive the action of the Yangian generators on color-ordered subsets of the external states. Each subset corresponds to a single boundary of the non-planar on-shell diagram. While Yangian invariance is broken, we find that higher-level Yangian generators still annihilate the non-planar on-shell diagram. For a given diagram, the number of these generators is governed by the degree of non-planarity. Furthermore, we present additional identities involving integrable transfer matrices. In particular, for diagrams on a cylinder we obtain a conservation rule similar to the Yangian invariance condition of planar on-shell diagrams. To exemplify our results, we consider a five-point MHV on-shell function on a cylinder.

  7. Oblique radiograph for the detection of bone spurs in anterior ankle impingement

    International Nuclear Information System (INIS)

    Dijk, Niek C. van; Wessel, Ronald N.; Tol, Johannes L.; Maas, M.

    2002-01-01

    Objective: The aim of this study was to develop a radiographic view to detect anteromedial talotibial osteophytes that remain undetected on standard radiographs. Design and patients: In 10 cadaver specimens the maximal size was measured of anteromedial tibial osteophytes that remain undetected on a standard lateral radiograph projection, due to the presence of the anteromedial tibial rim. The average projection of the most prominent anterolateral tibial rim over the anteromedial rim was found to be 7.3 mm. A 7 mm barium-clay osteophyte was attached to this anteromedial rim of the distal tibia. Anteromedial osteophytes become most prominent on an oblique view, in which the radiographic beam is tilted into a 45 craniocaudal direction with the leg in 30 external rotation. This oblique view was compared with the findings of arthroscopic surgery in 25 consecutive patients with anterior ankle impingement syndrome. Results: Medially located tibial and talar osteophytes remained undetected on a standard lateral projection and became visible on the oblique anteromedial impingement (AMI) radiograph. Anterolateral tibial and talar osteophytes were well detected on a standard lateral radiograph projection but were invisible on the AMI view. There was a high correlation between the location of the osteophyte and the location of symptoms and the findings at arthroscopy. Conclusion: A combination of lateral and oblique radiographs can be used to differentiate between anteromedial and anterolateral bony ankle impingement. (orig.)

  8. Oblique incidence of electron beams - comparisons between calculated and measured dose distributions

    International Nuclear Information System (INIS)

    Karcher, J.; Paulsen, F.; Christ, G.

    2005-01-01

    Clinical applications of high-energy electron beams, for example for the irradiation of internal mammary lymph nodes, can lead to oblique incidence of the beams. It is well known that oblique incidence of electron beams can alter the depth dose distribution as well as the specific dose per monitor unit. The dose per monitor unit is the absorbed dose in a point of interest of a beam, which is reached with a specific dose monitor value (DIN 6814-8[5]). Dose distribution and dose per monitor unit at oblique incidence were measured with a small-volume thimble chamber in a water phantom, and compared to both normal incidence and calculations of the Helax TMS 6.1 treatment planning system. At 4 MeV and 60 degrees, the maximum measured dose per monitor unit at oblique incidence was decreased up to 11%, whereas at 18MeV and 60 degrees this was increased up to 15% compared to normal incidence. Comparisons of measured and calculated dose distributions showed that the predicted dose at shallow depths is usually higher than the measured one, whereas it is smaller at depths beyond the depth of maximum dose. On the basis of the results of these comparisons, normalization depths and correction factors for the dose monitor value were suggested to correct the calculations of the dose per monitor unit. (orig.)

  9. Design of Human-Machine Interface and altering of pelvic obliquity with RGR Trainer.

    Science.gov (United States)

    Pietrusinski, Maciej; Unluhisarcikli, Ozer; Mavroidis, Constantinos; Cajigas, Iahn; Bonato, Paolo

    2011-01-01

    The Robotic Gait Rehabilitation (RGR) Trainer targets secondary gait deviations in stroke survivors undergoing rehabilitation. Using an impedance control strategy and a linear electromagnetic actuator, the device generates a force field to control pelvic obliquity through a Human-Machine Interface (i.e. a lower body exoskeleton). Herein we describe the design of the RGR Trainer Human-Machine Interface (HMI) and we demonstrate the system's ability to alter the pattern of movement of the pelvis during gait in a healthy subject. Results are shown for experiments during which we induced hip-hiking - in healthy subjects. Our findings indicate that the RGR Trainer has the ability of affecting pelvic obliquity during gait. Furthermore, we provide preliminary evidence of short-term retention of the modified pelvic obliquity pattern induced by the RGR Trainer. © 2011 IEEE

  10. A two-fluid study of oblique tearing modes in a force-free current sheet

    Energy Technology Data Exchange (ETDEWEB)

    Akçay, Cihan, E-mail: akcay@lanl.gov; Daughton, William [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Lukin, Vyacheslav S. [National Science Foundation, Arlington, Virginia 22230 (United States); Liu, Yi-Hsin [NASA Goddard Space Flight Center, Greenbelt, Maryland 20771 (United States)

    2016-01-15

    Kinetic simulations have demonstrated that three-dimensional reconnection in collisionless regimes proceeds through the formation and interaction of magnetic flux ropes, which are generated due to the growth of tearing instabilities at multiple resonance surfaces. Since kinetic simulations are intrinsically expensive, it is desirable to explore the feasibility of reduced two-fluid models to capture this complex evolution, particularly, in the strong guide field regime, where two-fluid models are better justified. With this goal in mind, this paper compares the evolution of the collisionless tearing instability in a force-free current sheet with a two-fluid model and fully kinetic simulations. Our results indicate that the most unstable modes are oblique for guide fields larger than the reconnecting field, in agreement with the kinetic results. The standard two-fluid tearing theory is extended to address the tearing instability at oblique angles. The resulting theory yields a flat oblique spectrum and underestimates the growth of oblique modes in a similar manner to kinetic theory relative to kinetic simulations.

  11. ytterbium- & erbium-doped silica for planar waveguide lasers & amplifiers

    DEFF Research Database (Denmark)

    Dyndgaard, Morten Glarborg

    2001-01-01

    The purpose of this work was to demonstrate ytterbium doped planar components and investigate the possibilities of making erbium/ytterbium codoped planar waveguides in germano-silica glass. Furthermore, tools for modelling lasers and erbium/ytterbium doped amplifiers. The planar waveguides were...

  12. Planar Poincare chart - A planar graphic representation of the state of light polarization

    Science.gov (United States)

    Tedjojuwono, Ken K.; Hunter, William W., Jr.; Ocheltree, Stewart L.

    1989-01-01

    The planar Poincare chart, which represents the complete planar equivalence of the Poincare sphere, is proposed. The four sets of basic lines are drawn on two separate charts for the generalization and convenience of reading the scale. The chart indicates the rotation of the principal axes of linear birefringent material. The relationships between parameters of the two charts are given as 2xi-2phi (orientation angle of the major axis-ellipticity angle) pair and 2alpha-delta (angle of amplitude ratio-phase difference angle) pair. The results are useful for designing and analyzing polarization properties of optical components with birefringent properties.

  13. Ion stochastic heating by obliquely propagating magnetosonic waves

    International Nuclear Information System (INIS)

    Gao Xinliang; Lu Quanming; Wu Mingyu; Wang Shui

    2012-01-01

    The ion motions in obliquely propagating Alfven waves with sufficiently large amplitudes have already been studied by Chen et al.[Phys. Plasmas 8, 4713 (2001)], and it was found that the ion motions are stochastic when the wave frequency is at a fraction of the ion gyro-frequency. In this paper, with test particle simulations, we investigate the ion motions in obliquely propagating magnetosonic waves and find that the ion motions also become stochastic when the amplitude of the magnetosonic waves is sufficiently large due to the resonance at sub-cyclotron frequencies. Similar to the Alfven wave, the increase of the propagating angle, wave frequency, and the number of the wave modes can lower the stochastic threshold of the ion motions. However, because the magnetosonic waves become more and more compressive with the increase of the propagating angle, the decrease of the stochastic threshold with the increase of the propagating angle is more obvious in the magnetosonic waves than that in the Alfven waves.

  14. Oblique ion texturing of yttria-stabilized zirconia: The {211} structure

    International Nuclear Information System (INIS)

    Berdahl, Paul; Reade, Ronald P.; Liu, Jinping; Russo, Richard E.; Fritzemeier, Les; Buczek, David; Schoop, Urs

    2002-01-01

    Amorphous (Zr,Y)O x films were synthesized by reactive magnetron sputtering and subsequently crystallized by oblique ion bombardment. Crystalline texture nucleated by the ion beam was replicated by solid-phase epitaxial growth throughout the formerly amorphous yttria-stabilized zirconia (YSZ) film. The resulting YSZ films have (211) orientation normal to the substrate with in-plane directions (111), parallel, and (110), transverse, to the azimuth of the ion beam. We hypothesize that the texture mechanism involves ion-induced film compression and shear. The results, taken together with prior work, show that oblique ion texturing of amorphous films is a general phenomenon that can be used to fabricate substrates with more than one type of crystallographic orientation

  15. Effects of squats accompanied by hip joint adduction on the selective activity of the vastus medialis oblique.

    Science.gov (United States)

    Hyong, In Hyouk

    2015-06-01

    [Purpose] This study evaluated the effective selective activation method of the vastus medialis oblique for knee joint stabilization in patients with patellofemoral pain syndrome. [Subjects and Methods] Fifteen healthy college students (9 males, 6 females); mean age, height, and weight: 22.2 years, 167.8 cm, and 61.4 kg, respectively) participated. The knee angle was held at 60°. Muscle activities were measured once each during an ordinary squat and a squat accompanied by hip joint adduction. The muscle activities of the vastus medialis oblique and vastus lateralis were measured by electromyography for five seconds while maintaining 60° knee flexion. Electromyography signals were obtained at a sampling rate of 1,000 Hz and band pass filtering at 20-50 Hz. The obtained raw root mean square was divided by the maximal voluntary isometric contraction and expressed as a percentage. The selective activity of the vastus medialis oblique was assessed according to the muscle activity ratio of the vastus medialis oblique to the vastus lateralis. [Results] The activity ratio of the vastus medialis oblique was higher during a squat with hip joint adduction than without. [Conclusion] A squat accompanied by hip joint adduction is effective for the selective activation of the vastus medialis oblique.

  16. Stellar Obliquity and Magnetic Activity of Planet-hosting Stars and Eclipsing Binaries Based on Transit Chord Correlation

    Science.gov (United States)

    Dai, Fei; Winn, Joshua N.; Berta-Thompson, Zachory; Sanchis-Ojeda, Roberto; Albrecht, Simon

    2018-04-01

    The light curve of an eclipsing system shows anomalies whenever the eclipsing body passes in front of active regions on the eclipsed star. In some cases, the pattern of anomalies can be used to determine the obliquity Ψ of the eclipsed star. Here we present a method for detecting and analyzing these patterns, based on a statistical test for correlations between the anomalies observed in a sequence of eclipses. Compared to previous methods, ours makes fewer assumptions and is easier to automate. We apply it to a sample of 64 stars with transiting planets and 24 eclipsing binaries for which precise space-based data are available, and for which there was either some indication of flux anomalies or a previously reported obliquity measurement. We were able to determine obliquities for 10 stars with hot Jupiters. In particular we found Ψ ≲ 10° for Kepler-45, which is only the second M dwarf with a measured obliquity. The other eight cases are G and K stars with low obliquities. Among the eclipsing binaries, we were able to determine obliquities in eight cases, all of which are consistent with zero. Our results also reveal some common patterns of stellar activity for magnetically active G and K stars, including persistently active longitudes.

  17. Early detection of breast cancer using only oblique medium lateral view

    International Nuclear Information System (INIS)

    Aguillar, Vera L.N.

    1996-01-01

    To compare the advantages of one- versus two-views mammography, screening films were reviewed from 1,500 asymptomatic women undergoing mammography. Two separate interpretations were made of each case, one using only the oblique projection images, the other using both oblique and cranio caudal views. In women with dense breasts, one view readings resulted in much more frequent abnormal interpretations, false positives, than two-views readings. In contrast, in woman with primary fatty breast, in whom superimposition of dense tissue on image is not a problem, it may be reasonable to obtain a single mediolateral projection to follow-up screening mammography. (author)

  18. Graded versus ungraded inferior oblique anterior transposition in patients with asymmetric dissociated vertical deviation.

    Science.gov (United States)

    Rajavi, Zhale; Feizi, Mohadeseh; Naderi, Ali; Sabbaghi, Hamideh; Behradfar, Narges; Yaseri, Mehdi; Faghihi, Mohammad

    2017-12-01

    To report the surgical outcomes of graded versus ungraded inferior oblique anterior transposition (IOAT) in treatment of patients with asymmetric dissociated vertical deviation (DVD) and bilateral inferior oblique overaction (IOOA). A total of 74 eyes of 37 patients with asymmetric DVD (interocular difference of ≥5 Δ ) and bilateral IOOA of > +1 were included in this randomized clinical trial. In the ungraded group (n = 18), both inferior oblique muscles were sutured at the inferior rectus level; in the graded group (n = 19), the inferior oblique muscles of eyes with more DVD were sutured at the level of the inferior rectus and inferior oblique muscles of eyes with less DVD were sutured 2 mm posterior to the level of the inferior rectus muscle. DVD was significantly reduced in each group (P < 0.001 for both). Although the postoperative mean difference of asymmetry of DVD was less in the ungraded group compared to the graded group (1.2 ± 1.9 vs 3.2 ± 1.2 [P = 0.001]), the absolute amounts of reduction of DVD asymmetry were similar (4.3 ± 2.3 vs 4.4 ± 3.1 [P = 0.78]). IOOA and V patterns were also reduced postoperatively. Each method of IOAT was effective in reducing DVD, asymmetry, IOOA, and V patterns. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  19. The effects of dynamic friction in oblique motorcycle helmet impacts

    Science.gov (United States)

    Bonugli, Enrique

    The purpose of this study was to determine the frictional properties between the exterior surface of a motorcycle helmet and 'typical' roadway surfaces. These values were compared to abrasive papers currently recommended by government helmet safety standards and widely used by researchers in the field of oblique motorcycle helmet impacts. A guided freefall test fixture was utilized to obtain nominal impact velocities of 5, 7 and 9 m/s. The impacting surfaces were mounted to an angled anvil to simulate off-centered oblique collision. Head accelerations and impact forces were measured for each test. Analysis of the normal and tangential forces imparted to the contact surface indicated that the frictional properties of abrasive papers differ from asphalt and cement in magnitude, duration and onset. Reduction in head acceleration, both linear and angular, were observed when asphalt and cement were used as the impacting surface. Roofing shingle was determined to be a more suitable material to simulate 'typical' roadway surfaces however, this may not be ideal for use in a controlled laboratory setting. In a laboratory setting, the author recommends cement as a best-fit material to simulate roadway surface for use in oblique motorcycle helmet impacts since this material displayed characteristics that closely resemble asphalt and is currently used as a roadway construction material.

  20. Oblique Photogrammetry Supporting 3d Urban Reconstruction of Complex Scenarios

    Science.gov (United States)

    Toschi, I.; Ramos, M. M.; Nocerino, E.; Menna, F.; Remondino, F.; Moe, K.; Poli, D.; Legat, K.; Fassi, F.

    2017-05-01

    Accurate 3D city models represent an important source of geospatial information to support various "smart city" applications, such as space management, energy assessment, 3D cartography, noise and pollution mapping as well as disaster management. Even though remarkable progress has been made in recent years, there are still many open issues, especially when it comes to the 3D modelling of complex urban scenarios like historical and densely-built city centres featuring narrow streets and non-conventional building shapes. Most approaches introduce strong building priors/constraints on symmetry and roof typology that penalize urban environments having high variations of roof shapes. Furthermore, although oblique photogrammetry is rapidly maturing, the use of slanted views for façade reconstruction is not completely included in the reconstruction pipeline of state-of-the-art software. This paper aims to investigate state-of-the-art methods for 3D building modelling in complex urban scenarios with the support of oblique airborne images. A reconstruction approach based on roof primitives fitting is tested. Oblique imagery is then exploited to support the manual editing of the generated building models. At the same time, mobile mapping data are collected at cm resolution and then integrated with the aerial ones. All approaches are tested on the historical city centre of Bergamo (Italy).

  1. Retroperitoneal and lateral pelvic lymphadenectomy mapped by lymphoscintigraphy for rectal adenocarcinoma staging

    International Nuclear Information System (INIS)

    Quadros, C.A.; Araujo, I.; Lopes, A.

    2010-01-01

    The good prognosis of retroperitoneal and lateral pelvic lymphadenectomy has raised the question of whether total mesorectal excision is suitable for adequate staging of rectal adenocarcinoma patients. The aims of this study were to determine the accuracy of dye and probe detection of metastatic retroperitoneal and/or lateral pelvic nodes and to define the upstaging impact of retroperitoneal and lateral pelvic lymphadenectomy in rectal adenocarcinoma patients. Ninety-seven rectal adenocarcinoma patients were submitted to total mesorectal excision and retroperitoneal and lateral pelvic lymphadenectomy. Lymphoscintigraphy using technetium-99 m-phytate and patent blue was performed to detect blue and/or radioactive retroperitoneal and/or lateral pelvic nodes which were examined histopathologically and immunohistochemically with a step-sectioning technique. Mesorectal mean node count was 11.5 and retroperitoneal and/or lateral pelvic node was 11.7. Retroperitoneal and lateral pelvic lymphadenectomy identified metastases in 17.5%, upstaging 8.2%. Variables related to metastatic retroperitoneal and/or lateral pelvic nodes were the following: Stage III in total mesorectal excision specimens (P<0.04), pT3/pT4 tumors (P=0.047), high levels of carcinoembryonic antigen (P=0.014) and large tumors (P=0.03). Marker migration to retroperitoneal and/or lateral pelvic nodes occurred in 37.1%, upstaging 11.1%. The markers' accuracy in the detection of metastatic retroperitoneal and/or lateral pelvic nodes was 100%. Retroperitoneal and lateral pelvic lymphadenectomy detected an important rate of metastatic retroperitoneal and/or lateral pelvic nodes (RLPN), resulting in upstaging. When markers migrated, they were able to detect RLPN metastases. The use of markers should be improved in the identification of RLPN metastases for selective indication of retroperitoneal and lateral pelvic lymphadenectomy. (author)

  2. Infra Patellar Branch of Saphenous Nerve Injury during Hamstring Graft Harvest: Vertical versus Oblique Incisions.

    Science.gov (United States)

    Joshi, A; Kayasth, N; Shrestha, S; Kc, B R

    2016-09-01

    Autologous hamstring grafts are commonly used for anterior cruciate ligament reconstruction. The injury of infrapatellar branch of saphenous nerve is one of the concerns leading to various pattern of sensory loss in the operated leg. An oblique incision to harvest the graft has been reported to be better than the vertical one.The aim of this study was to compare the incidence, recovery of nerve injury and final outcome in patients with hamstring harvest of vertical or oblique incision. A total of 146 patients who underwent hamstring graft harvest for anterior cruciate ligament reconstruction, were included in the study. They were randomized into two (Vertical and Oblique) groups as per the incisions used. The sensory loss along the Infra Patellar Branch of Saphenous Nerve was documented on 3rd day. Recovery of the nerve injury was monitoredat three, six and 12 months follow-ups. At final follow up Tegner Lysholm score and scale was recorded to compare between two groups. The incidence of infrapatellar branch of saphenous nerve injury was 25% in vertical group and 16.36% in oblique group. Recovery of nerve injury started earlier in oblique group compared to vertical group. The mean TegnerLyshom score was not significantly different in both the groups. Oblique incision to harvest hamstring graft has lesser incidence of infrapatellar branch of saphenous nerve injury, recovers earlier and does not have any adverse effect on final outcome compared to the vertical incision.

  3. Oblique hilar tomography, computed tomography, and mediastinoscopy for prethoracotomy staging of bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Khan, A.; Gersten, K.C.; Garvey, J.; Khan, F.A.; Steinberg, H.

    1985-01-01

    Preoperative oblique hilar tomography was used to evaluate hilar lymph nodes in 150 patients with clinically resectable bronchogenic carcinoma. CT was also used in the evaluation of mediastinal lymph nodes in 50 of these patients. Subsequently, all patients underwent mediastinoscopy and/or thoracotomy. Hilar and mediastinal nodes were evaluated for the presence of metastasis, and these findings were then correlated with the radiographic findings of oblique hilar tomography and CT. CT was found to be a reliable method for prethoracotomy staging of bronchogenic carcinoma and for selecting patients for mediastinoscopy. Thus patients with negative mediastinal CT need not undergo mediastinoscopy prior to thoracotomy, while mediastinoscopy and biopsy should be done in patients with enlarged mediastinal nodes on CT. Oblique hilar tomography is an accurate method for evaluation of hilar adenopathy and for predicting mediastinal involvement by extrapolation

  4. Continental breakup by oblique extension: the Gulf of California

    Science.gov (United States)

    van Wijk, J.; Axen, G. J.

    2017-12-01

    We address two aspects of oblique extension: 1) the evolution of pull-apart basins, and how/when they may evolve into seafloor spreading segments; and 2) the formation of microcontinents. The Gulf of California formed by oblique extension. Breakup resulted in oceanic crust generation in the southern and central parts, while in the northern Gulf/Salton Trough a thick layer of (meta-)sediments overlies thinned continental crust. We propose a simple mechanism to explain this N-S variation. We assume that oblique rifting of the proto-Gulf province resulted in pull-apart basins, and use numerical models to show that such pull-apart basins do not develop into seafloor spreading segments when their length-to-width ratios are small, as is the case in the northern Gulf. In the central and southern Gulf the length-to-width ratios were larger, promoting continent rupture. The mechanisms behind this fate of pull-apart basins will be discussed in the presentation. In the southern Gulf, potential field models show that the Tamayo Bank in the southern Gulf is likely a microcontinent, separated from the main continent by the Tamayo trough. The thickness of the ocean crust in the Tamayo trough is anomalously small, suggesting that initial seafloor spreading was magma-starved and unsuccessful, causing the location of rifting and seafloor spreading to jump. As a consequence a sliver of continent broke off, forming the microcontinent. We suggest that worldwide this may be a common process for microcontinent formation.

  5. Flat panel planar optic display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T. [Brookhaven National Lab., Upton, NY (United States). Dept. of Advanced Technology

    1994-11-01

    A prototype 10 inch flat panel Planar Optic Display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic class sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  6. Planar Algebra of the Subgroup-Subfactor

    Indian Academy of Sciences (India)

    The crucial step in this identification is an exhibition of a model for the basic construction tower, and thereafter of the standard invariant of R ⋊ H ⊂ R ⋊ G in terms of operator matrices. We also obtain an identification between the planar algebra of the fixed algebra subfactor R G ⊂ R H and the -invariant planar subalgebra ...

  7. Technical errors in planar bone scanning.

    Science.gov (United States)

    Naddaf, Sleiman Y; Collier, B David; Elgazzar, Abdelhamid H; Khalil, Magdy M

    2004-09-01

    Optimal technique for planar bone scanning improves image quality, which in turn improves diagnostic efficacy. Because planar bone scanning is one of the most frequently performed nuclear medicine examinations, maintaining high standards for this examination is a daily concern for most nuclear medicine departments. Although some problems such as patient motion are frequently encountered, the degraded images produced by many other deviations from optimal technique are rarely seen in clinical practice and therefore may be difficult to recognize. The objectives of this article are to list optimal techniques for 3-phase and whole-body bone scanning, to describe and illustrate a selection of deviations from these optimal techniques for planar bone scanning, and to explain how to minimize or avoid such technical errors.

  8. Multiple Climate States of Habitable Exoplanets: The Role of Obliquity and Irradiance

    International Nuclear Information System (INIS)

    Kilic, C.; Raible, C. C.; Stocker, T. F.

    2017-01-01

    Stable, steady climate states on an Earth-size planet with no continents are determined as a function of the tilt of the planet’s rotation axis (obliquity) and stellar irradiance. Using a general circulation model of the atmosphere coupled to a slab ocean and a thermodynamic sea ice model, two states, the Aquaplanet and the Cryoplanet, are found for high and low stellar irradiance, respectively. In addition, four stable states with seasonally and perennially open water are discovered if comprehensively exploring a parameter space of obliquity from 0° to 90° and stellar irradiance from 70% to 135% of the present-day solar constant. Within 11% of today’s solar irradiance, we find a rich structure of stable states that extends the area of habitability considerably. For the same set of parameters, different stable states result if simulations are initialized from an aquaplanet or a cryoplanet state. This demonstrates the possibility of multiple equilibria, hysteresis, and potentially rapid climate change in response to small changes in the orbital parameters. The dynamics of the atmosphere of an aquaplanet or a cryoplanet state is investigated for similar values of obliquity and stellar irradiance. The atmospheric circulation substantially differs in the two states owing to the relative strength of the primary drivers of the meridional transport of heat and momentum. At 90° obliquity and present-day solar constant, the atmospheric dynamics of an Aquaplanet state and one with an equatorial ice cover is analyzed.

  9. Multiple Climate States of Habitable Exoplanets: The Role of Obliquity and Irradiance

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, C.; Raible, C. C.; Stocker, T. F., E-mail: stocker@climate.unibe.ch [Climate and Environmental Physics, Physics Institute, University of Bern (Switzerland)

    2017-08-01

    Stable, steady climate states on an Earth-size planet with no continents are determined as a function of the tilt of the planet’s rotation axis (obliquity) and stellar irradiance. Using a general circulation model of the atmosphere coupled to a slab ocean and a thermodynamic sea ice model, two states, the Aquaplanet and the Cryoplanet, are found for high and low stellar irradiance, respectively. In addition, four stable states with seasonally and perennially open water are discovered if comprehensively exploring a parameter space of obliquity from 0° to 90° and stellar irradiance from 70% to 135% of the present-day solar constant. Within 11% of today’s solar irradiance, we find a rich structure of stable states that extends the area of habitability considerably. For the same set of parameters, different stable states result if simulations are initialized from an aquaplanet or a cryoplanet state. This demonstrates the possibility of multiple equilibria, hysteresis, and potentially rapid climate change in response to small changes in the orbital parameters. The dynamics of the atmosphere of an aquaplanet or a cryoplanet state is investigated for similar values of obliquity and stellar irradiance. The atmospheric circulation substantially differs in the two states owing to the relative strength of the primary drivers of the meridional transport of heat and momentum. At 90° obliquity and present-day solar constant, the atmospheric dynamics of an Aquaplanet state and one with an equatorial ice cover is analyzed.

  10. Screech Tones from Rectangular Jets with Spanwise Oblique Shock-Cell Structures

    Science.gov (United States)

    Raman, Ganesh

    1996-01-01

    Understanding screech is especially important for the design of advanced aircraft because screech can cause sonic fatigue failure of aircraft structures. Although the connection between shock-cell spacing and screech frequency is well understood, the relation between non-uniformities in the shock-cell structures and the resulting amplitude, mode, and steadiness of screech have remained unexplored. This paper addresses the above issues by intentionally producing spanwise (larger nozzle dimension) variations in the shock-cell structures and studying the resulting spanwise screech mode. The spanwise oblique shock-cell structures were produced using imperfectly expanded convergent-divergent rectangular nozzles (aspect ratio = 5) with nonuniform exit geometries. Three geometries were studied: (a) a nozzle with a spanwise uniform edge, (b) a nozzle with a spanwise oblique (single bevelled) edge, and (c) a nozzle that had two spanwise oblique (double bevelled) cuts to form an arrowhead-shaped nozzle. For all nozzles considered, the screech mode was antisymmetric in the transverse (smaller nozzle dimension) direction allowing focus on changes in the spanwise direction. Three types of spanwise modes were observed: symmetric (1), antisymmetric (2), and oblique (3). The following significant results emerged: (1) for all cases the screech mode corresponds with the spanwise shock-cell structure, (2) when multiple screech modes are present, the technique presented here makes it possible to distinguish between coexisting and mutually exclusive modes, (3) the strength of shocks 3 and 4 influences the screech source amplitude and determines whether screech is unsteady. The results presented here offer hope for a better understanding of screech and for tailoring shock-containing jets to minimize fatigue failure of aircraft components.

  11. Designing safer composite helmets to reduce rotational accelerations during oblique impacts.

    Science.gov (United States)

    Mosleh, Yasmine; Cajka, Martin; Depreitere, Bart; Vander Sloten, Jos; Ivens, Jan

    2018-05-01

    Oblique impact is the most common accident situation that occupants in traffic accidents or athletes in professional sports experience. During oblique impact, the human head is subjected to a combination of linear and rotational accelerations. Rotational movement is known to be responsible for traumatic brain injuries. In this article, composite foam with a column/matrix composite configuration is proposed for head protection applications to replace single-layer uniform foam, to better attenuate rotational movement of the head during oblique impacts. The ability of composite foam in the mitigation of rotational head movement is studied by performing finite element (FE) simulations of oblique impact on flat and helmet shape specimens. The performance of composite foam with respect to parameters such as compliance of the matrix foam and the number, size and cross-sectional shape of the foam columns is explored in detail, and subsequently an optimized structure is proposed. The simulation results show that using composite foam instead of single-layer foam, the rotational acceleration and velocity of the headform can be significantly reduced. The parametric study indicates that using a more compliant matrix foam and by increasing the number of columns in the composite foam configuration, the rotation can be further mitigated. This was confirmed by experimental results. The simulation results were also analyzed based on global head injury criteria such as head injury criterion, rotational injury criterion, brain injury criterion and generalized acceleration model for brain injury threshold which further confirmed the superior performance of composite foam versus single-layer homogeneous expanded polystyrene foam. The findings of simulations give invaluable information for design of protective helmets or, for instance, headliners for the automotive industry.

  12. Lymphoscintigraphy in paediatric patients for suspected lymphoedema: normal variants, abnormal and syndromic patterns

    International Nuclear Information System (INIS)

    Pascual, T.; Howman-Giles, R.; Martin, H.

    2009-01-01

    Full text: Background: Lymphoscintigraphy (LS) is the diagnostic test of choice differentiating lymphoedema from other causes of extremity swelling. The LS patterns in normal and congenital lymphoedema in the paediatric population are not well defined. The impact of LS on clinical decision making is also not well reported. Aims: 1. define normal LS patterns in the pediatric population 2. describe types of abnormality (aplasia, hypoplasia, hyperplasia/dilated system) 3. describe LS patterns in syndromic lymphatic vascular disease 4. correlate LS with clinical impact on patient management. Methods: Retrospective review of all paediatric patients who had LS from July 1996-April 2008 was undertaken. Indications, sites of abnormality, LS patterns and clinical outcome were reviewed. Results: 118 patients (3mths-21yrs, mean 6 yrs) underwent LS. Normal LS patterns and variations were identified in 57 pts (48%). Sixty-one scans (52%) were abnormal showing lymph node aplasia (11%), hypoplasia (17%), mixed-pattern (8%), hyperplasia/dilated system (4%) and other patterns ie intestinal/pulmonary lymphangiectasia and vascual lymphatic malformations (11%). Patients with no signs of lymphoedema may still have aplasia or hypoplasia on LS. Dermal back flow is not always seen in lymphoedema. Management impact related to diagnosis and potential for development of lymphoedema in other limbs, differentiation of lymphoedema in patients with other vascular anomalies, stratification for lymphoedema therapy or referral to the dysmorphology clinic. Conclusion: LS is a valuable tool in the evaluation of lymphoedema in pediatric patients. Recognition of scan patterns in patients with suspected lymphoedema or lymphatic vascular diseases is essential as it plays a major role in the clinical management.

  13. Modulational instability of the obliquely modulated ion acoustic waves in a warm ion plasma

    International Nuclear Information System (INIS)

    Saxena, M.K.; Arora, A.K.; Sharma, S.R.

    1981-01-01

    Using KBM. perturbation technique, it is shown that the modulationally unstable domain in the (kappa - phi) plane for the obliquely modulated ion acoustic waves is appreciably modified due to the finite ion temperature. It is also shown that in a collisionless plasma having small TAUsub(i)/TAUsub(e) ( 0 approximately 0.1) may exceed the Landau damping rate provided the modulation is sufficiently oblique. (author)

  14. On Longest Cycles in Essentially 4-Connected Planar Graphs

    Directory of Open Access Journals (Sweden)

    Fabrici Igor

    2016-08-01

    Full Text Available A planar 3-connected graph G is essentially 4-connected if, for any 3-separator S of G, one component of the graph obtained from G by removing S is a single vertex. Jackson and Wormald proved that an essentially 4-connected planar graph on n vertices contains a cycle C such that . For a cubic essentially 4-connected planar graph G, Grünbaum with Malkevitch, and Zhang showed that G has a cycle on at least ¾ n vertices. In the present paper the result of Jackson and Wormald is improved. Moreover, new lower bounds on the length of a longest cycle of G are presented if G is an essentially 4-connected planar graph of maximum degree 4 or G is an essentially 4-connected maximal planar graph.

  15. Role of the technologist in the lymphoscintigraphy and the identification of sentinel node in malignant skin melanoma

    International Nuclear Information System (INIS)

    Barbier, D.

    2002-01-01

    The biopsy of the first tumor-draining lymph node (sentinel node) is bound to become the procedure of choice in regional staging of skin melanoma patients. In our department, we do successively: lymphoscintigraphy; identification of sentinel node by γ probe before surgery; identification during surgery of sentinel node with γ probe. During those different steps, the technologist has an important role. The different steps of the technologist's work are: Preparation of radiopharmaceutical Tc 99m Nanocolloides (Nanocis Cis Bio Int); Control of radio chemical purity(RCP) by thin-layer chromatography (TLC); Programming of acquisition protocol on the γ camera; Acquisition of dynamic and static images; Identification percutaneous of the sentinel node with the γ probe and Co 57 pencil; Processing of scintigraphic images; At least identification with surgeon of the sentinel node. After excision of the lymph node, we have to verify the disappearing of radioactivity. Those steps will be illustrated by different clinical cases. Conclusion: Sentinel node identification is: New useful technique for patient: not very much invasive; screening of patients with high risk factors; great parameters of prognosis; Interest for technologist: narrow collaboration with nuclearist and surgeon; psychological role close to the patient; various competency of technologist; diagnostic and therapeutic participations

  16. Design of Human – Machine Interface and Altering of Pelvic Obliquity with RGR Trainer

    Science.gov (United States)

    Pietrusinski, Maciej; Unluhisarcikli, Ozer; Mavroidis, Constantinos; Cajigas, Iahn; Bonato, Paolo

    2012-01-01

    The Robotic Gait Rehabilitation (RGR) Trainer targets secondary gait deviations in stroke survivors undergoing rehabilitation. Using an impedance control strategy and a linear electromagnetic actuator, the device generates a force field to control pelvic obliquity through a Human-Machine Interface (i.e. a lower body exoskeleton). Herein we describe the design of the RGR Trainer Human-Machine Interface (HMI) and we demonstrate the system’s ability to alter the pattern of movement of the pelvis during gait in a healthy subject. Results are shown for experiments during which we induced hip-hiking – in healthy subjects. Our findings indicate that the RGR Trainer has the ability of affecting pelvic obliquity during gait. Furthermore, we provide preliminary evidence of short-term retention of the modified pelvic obliquity pattern induced by the RGR Trainer. PMID:22275693

  17. CALIBRATION PROCEDURES ON OBLIQUE CAMERA SETUPS

    Directory of Open Access Journals (Sweden)

    G. Kemper

    2016-06-01

    Full Text Available Beside the creation of virtual animated 3D City models, analysis for homeland security and city planning, the accurately determination of geometric features out of oblique imagery is an important task today. Due to the huge number of single images the reduction of control points force to make use of direct referencing devices. This causes a precise camera-calibration and additional adjustment procedures. This paper aims to show the workflow of the various calibration steps and will present examples of the calibration flight with the final 3D City model. In difference to most other software, the oblique cameras are used not as co-registered sensors in relation to the nadir one, all camera images enter the AT process as single pre-oriented data. This enables a better post calibration in order to detect variations in the single camera calibration and other mechanical effects. The shown sensor (Oblique Imager is based o 5 Phase One cameras were the nadir one has 80 MPIX equipped with a 50 mm lens while the oblique ones capture images with 50 MPix using 80 mm lenses. The cameras are mounted robust inside a housing to protect this against physical and thermal deformations. The sensor head hosts also an IMU which is connected to a POS AV GNSS Receiver. The sensor is stabilized by a gyro-mount which creates floating Antenna –IMU lever arms. They had to be registered together with the Raw GNSS-IMU Data. The camera calibration procedure was performed based on a special calibration flight with 351 shoots of all 5 cameras and registered the GPS/IMU data. This specific mission was designed in two different altitudes with additional cross lines on each flying heights. The five images from each exposure positions have no overlaps but in the block there are many overlaps resulting in up to 200 measurements per points. On each photo there were in average 110 well distributed measured points which is a satisfying number for the camera calibration. In a first

  18. Effect of Oblique-Angle Sputtered ITO Electrode in MAPbI3 Perovskite Solar Cell Structures.

    Science.gov (United States)

    Lee, Kun-Yi; Chen, Lung-Chien; Wu, Yu-June

    2017-10-03

    This investigation reports on the characteristics of MAPbI 3 perovskite films on obliquely sputtered ITO/glass substrates that are fabricated with various sputtering times and sputtering angles. The grain size of a MAPbI 3 perovskite film increases with the oblique sputtering angle of ITO thin films from 0° to 80°, indicating that the surface properties of the ITO affect the wettability of the PEDOT:PSS thin film and thereby dominates the number of perovskite nucleation sites. The optimal power conversion efficiency (Eff) is achieved 11.3% in a cell with an oblique ITO layer that was prepared using a sputtering angle of 30° for a sputtering time of 15 min.

  19. Oblique Alfvén instabilities driven by compensated currents

    Energy Technology Data Exchange (ETDEWEB)

    Malovichko, P. [Main Astronomical Observatory, NASU, Kyiv (Ukraine); Voitenko, Y.; De Keyser, J., E-mail: voitenko@oma.be [Solar-Terrestrial Centre of Excellence, Space Physics Division, Belgian Institute for Space Aeronomy, Ringlaan-3-Avenue Circulaire, B-1180 Brussels (Belgium)

    2014-01-10

    Compensated-current systems created by energetic ion beams are widespread in space and astrophysical plasmas. The well-known examples are foreshock regions in the solar wind and around supernova remnants. We found a new oblique Alfvénic instability driven by compensated currents flowing along the background magnetic field. Because of the vastly different electron and ion gyroradii, oblique Alfvénic perturbations react differently on the currents carried by the hot ion beams and the return electron currents. Ultimately, this difference leads to a non-resonant aperiodic instability at perpendicular wavelengths close to the beam ion gyroradius. The instability growth rate increases with increasing beam current and temperature. In the solar wind upstream of Earth's bow shock, the instability growth time can drop below 10 proton cyclotron periods. Our results suggest that this instability can contribute to the turbulence and ion acceleration in space and astrophysical foreshocks.

  20. Oblique Alfvén instabilities driven by compensated currents

    International Nuclear Information System (INIS)

    Malovichko, P.; Voitenko, Y.; De Keyser, J.

    2014-01-01

    Compensated-current systems created by energetic ion beams are widespread in space and astrophysical plasmas. The well-known examples are foreshock regions in the solar wind and around supernova remnants. We found a new oblique Alfvénic instability driven by compensated currents flowing along the background magnetic field. Because of the vastly different electron and ion gyroradii, oblique Alfvénic perturbations react differently on the currents carried by the hot ion beams and the return electron currents. Ultimately, this difference leads to a non-resonant aperiodic instability at perpendicular wavelengths close to the beam ion gyroradius. The instability growth rate increases with increasing beam current and temperature. In the solar wind upstream of Earth's bow shock, the instability growth time can drop below 10 proton cyclotron periods. Our results suggest that this instability can contribute to the turbulence and ion acceleration in space and astrophysical foreshocks.

  1. AUTOMATIC BUILDING OUTLINING FROM MULTI-VIEW OBLIQUE IMAGES

    Directory of Open Access Journals (Sweden)

    J. Xiao

    2012-07-01

    Full Text Available Automatic building detection plays an important role in many applications. Multiple overlapped airborne images as well as lidar point clouds are among the most popular data sources used for this purpose. Multi-view overlapped oblique images bear both height and colour information, and additionally we explicitly have access to the vertical extent of objects, therefore we explore the usability of this data source solely to detect and outline buildings in this paper. The outline can then be used for further 3D modelling. In the previous work, building hypotheses are generated using a box model based on detected façades from four directions. In each viewing direction, façade edges extracted from images and height information by stereo matching from an image pair is used for the façade detection. Given that many façades were missing due to occlusion or lack of texture whilst building roofs can be viewed in most images, this work mainly focuses on improve the building box outline by adding roof information. Stereo matched point cloud generated from oblique images are combined with the features from images. Initial roof patches are located in the point cloud. Then AdaBoost is used to integrate geometric and radiometric attributes extracted from oblique image on grid pixel level with the aim to refine the roof area. Generalized contours of the roof pixels are taken as building outlines. The preliminary test has been done by training with five buildings and testing around sixty building clusters. The proposed method performs well concerning covering the irregular roofs as well as improve the sides location of slope roof buildings. Outline result comparing with cadastral map shows almost all above 70% completeness and correctness in an area-based assessment, as well as 20% to 40% improvement in correctness with respect to our previous work.

  2. Planar half-cell shaped precursor body

    DEFF Research Database (Denmark)

    2015-01-01

    The invention relates to a half-cell shaped precursor body of either anode type or cathode type, the half-cell shaped precursor body being prepared to be free sintered to form a sintered or pre-sintered half-cell being adapted to be stacked in a solid oxide fuel cell stack. The obtained half......-cell has an improved planar shape, which remains planar also after a sintering process and during temperature fluctuations....

  3. Flow control for oblique shock wave reflections

    OpenAIRE

    Giepman, R.H.M.

    2016-01-01

    Shock wave-boundary layer interactions are prevalent in many aerospace applications that involve transonic or supersonic flows. Such interactions may lead to boundary layer separation, flow unsteadiness and substantial losses in the total pressure. Flow control techniques can help to mitigate these adverse effects and stabilize the interaction. This thesis focuses on passive flow control techniques for oblique shock wave reflections on flat plates and presents experimental results for both la...

  4. Piezo Voltage Controlled Planar Hall Effect Devices.

    Science.gov (United States)

    Zhang, Bao; Meng, Kang-Kang; Yang, Mei-Yin; Edmonds, K W; Zhang, Hao; Cai, Kai-Ming; Sheng, Yu; Zhang, Nan; Ji, Yang; Zhao, Jian-Hua; Zheng, Hou-Zhi; Wang, Kai-You

    2016-06-22

    The electrical control of the magnetization switching in ferromagnets is highly desired for future spintronic applications. Here we report on hybrid piezoelectric (PZT)/ferromagnetic (Co2FeAl) devices in which the planar Hall voltage in the ferromagnetic layer is tuned solely by piezo voltages. The change of planar Hall voltage is associated with magnetization switching through 90° in the plane under piezo voltages. Room temperature magnetic NOT and NOR gates are demonstrated based on the piezo voltage controlled Co2FeAl planar Hall effect devices without the external magnetic field. Our demonstration may lead to the realization of both information storage and processing using ferromagnetic materials.

  5. Attractive planar panelization using dynamic relaxation principles

    NARCIS (Netherlands)

    Gauss, Florian; Teuffel, Patrick

    2015-01-01

    In the presented paper a new method is proposed to approximate a given NURBS surface with a PQ (Planar Quad) mesh. The desired mesh layout will be generated in then attracted to the target surface. The process iteratively pulls the mesh vertices towards the target surface and then planarizes the

  6. Planar Hall effect bridge magnetic field sensors

    DEFF Research Database (Denmark)

    Henriksen, A.D.; Dalslet, Bjarke Thomas; Skieller, D.H.

    2010-01-01

    Until now, the planar Hall effect has been studied in samples with cross-shaped Hall geometry. We demonstrate theoretically and experimentally that the planar Hall effect can be observed for an exchange-biased ferromagnetic material in a Wheatstone bridge topology and that the sensor signal can...... Hall effect bridge sensors....

  7. Column Planarity and Partially-Simultaneous Geometric Embedding

    Czech Academy of Sciences Publication Activity Database

    Barba, L.; Evans, W.; Hoffmann, M.; Kusters, V.; Saumell, Maria; Speckmann, B.

    2017-01-01

    Roč. 21, č. 6 (2017), s. 983-1002 ISSN 1526-1719 Grant - others:GA MŠk(CZ) LO1506; GA MŠk(CZ) EE2.3.30.0038 Institutional support: RVO:67985807 Keywords : column planarity * unlabeled level planarity * simultaneous geometric embedding Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics

  8. Pulsed laser planarization of metal films for multilevel interconnects

    International Nuclear Information System (INIS)

    Tuckerman, D.B.; Schmitt, R.L.

    1985-05-01

    Multilevel interconnect schemes for integrated circuits generally require one or more planarization steps, in order to maintain an acceptably flat topography for lithography and thin-film step coverage on the higher levels. Traditional approaches have involved planarization of the interlevel insulation (dielectric) layers, either by spin-on application (e.g., polyimide), or by reflow (e.g., phosphosilicate glass). We have pursued an alternative approach, in which each metal level is melted (hence planarized) using a pulsed laser prior to patterning. Short (approx.1 μs) pulses are used to preclude undesirable metallurgical reactions between the film, adhesion or barrier layer, and dielectric layer. Laser planarization of metals is particularly well suited to multilevel systems which include ground or power planes. Results are presented for planarization of gold films on SiO 2 dielectric layers using a flashlamp-pumped dye laser. The pulse duration is approx.1 μs, which allows the heat pulse to uniformly penetrate the gold while not penetrating substantially through the underlying SiO 2 (hence not perturbing the lower levels of metal). Excellent planarization of the gold films is achieved (less than 0.1 μm surface roughness, even starting with extreme topographic variations), as well as improved conductivity. To demonstrate the process, numerous planarized two-layer structures (transmission lines under a ground plane) were fabricated and characterized. 9 refs., 2 figs

  9. Sound absorption of a new oblique-section acoustic metamaterial with nested resonator

    Science.gov (United States)

    Gao, Nansha; Hou, Hong; Zhang, Yanni; Wu, Jiu Hui

    2018-02-01

    This study designs and investigates high-efficiency sound absorption of new oblique-section nested resonators. Impedance tube experiment results show that different combinations of oblique-section nest resonators have tunable low-frequency bandwidth characteristics. The sound absorption mechanism is due to air friction losses in the slotted region and the sample structure resonance. The acousto-electric analogy model demonstrates that the sound absorption peak and bandwidth can be modulated over an even wider frequency range by changing the geometric size and combinations of structures. The proposed structure can be easily fabricated and used in low-frequency sound absorption applications.

  10. Thyroid-Associated Orbitopathy with Superior Oblique Muscle Involvement: A Case Report

    Directory of Open Access Journals (Sweden)

    Horng-Jiun Wu

    2004-02-01

    Full Text Available A 29-year-old male with a 5-year-history of hyperthyroidism complained of diplopia and proptosis. After subtotal thyroidectomy, he still had diplopia in a certain gaze. Computerized tomography showed inferior rectus muscle enlargement in the right eye and inferior rectus, medial rectus, and superior oblique muscle enlargement in the left eye. Ocular examination with the cover and uncover test revealed hyperphoria and exophoria in the left eye. The upward gaze of the right eye was more limited than that of the left eye. Since superior oblique muscle involvement in patients with thyroid orbitopathy is quite rare, we discuss its effect on ocular motility in patients with thyroid-associated orbitopathy.

  11. Lymphoscintigraphy detecting alterations of upper limb lymphatic flow following early sentinel lymph node biopsy in breast cancer

    Directory of Open Access Journals (Sweden)

    Sarri AJ

    2017-04-01

    Full Text Available Almir Jose Sarri,1 Eduardo Tinois da Silva,2 Rene Aloisio da Costa Vieira,3 Katia Hiromoto Koga,2 Pedro Henrique Moriguchi Cação,4 Vitor Coca Sarri,5 Sonia Marta Moriguchi2 1Department of Physical Therapy, Barretos Cancer Hospital, Barretos, Sao Paulo, 2Department of Tropical Diseases and Diagnostic Imaging, Botucatu Medical School, Sao Paulo State University – UNESP, Botucatu, 3Department of Mastology and Reconstructive Surgery, Barretos Cancer Hospital, Barretos, 4Department of Radiology – Faculdade de Medicina de São José do Rio Preto (FAMERP, 5Medical School, University of Franca, Sao Paulo, Brazil Purpose: To evaluate early variations in lymphatic circulation of the arm pre- and post-sentinel lymph node biopsy (SLNB and conservative breast surgery by lymphoscintigraphy (LS.Patients and methods: Between 2005 and 2012, 15 patients underwent LS before and after the SLNB (total=30 studies. The pre-SLNB study was considered the control. Early images within twenty minutes (dynamic and static images and delayed images within ninety minutes of arms and armpits were acquired using a gamma camera. The LS images before and after the SLNB of each patient were paired and compared to each other, evaluating the site of lymphatic flow (in the early phase and identifying the number of lymph nodes (in the late phase. These dynamic images were subjected to additional quantitative analysis to assess the lymphatic flow rate using the slope assessed by the angular coefficient of the radioactivity × time curves in areas of interest recorded in the axillary region. The variations of lymphatic flow and the number of lymph nodes in the post-SLNB LS compared to the pre-SLNB LS of each patient were classified as decreased, sustained or increased. The clinical variables analyzed included the period between performing the SLNB and the subsequent LS imaging, age, body mass index, number of removed lymph nodes, type of surgery and whether immediate oncoplastic

  12. Treatment for incarcerated indirect hernia with "Cross-Internal Ring" inguinal oblique incision in children.

    Science.gov (United States)

    Yan, Xue-Qiang; Yang, Jun; Zheng, Nan-Nan; Kuang, Hou-Fang; Duan, Xu-Fei; Bian, Hong-Qiang

    2017-01-01

    This study aims to evaluate the utility of the "Cross-Internal Ring" inguinal oblique incision for the surgical treatment of incarcerated indirect hernia (IIH) complicated with severe abdominal distension. Patients of IIH complicated with severe abdominal distension were reviewed retrospectively. All patients received operation through the "Cross-Internal Ring" inguinal oblique incision. There were totally 13 patients were included, male to female ratio was 9-4. The time for patients to resume oral feeding varying from 2 to 5 days after operation, no complications include delayed intestinal perforation, intra-abdominal abscess, and incision infection happened. Average postoperative hospital stay was 5.2 days. All cases were followed up for 6-18 months. No recurrence or iatrogenic cryptorchidism happened. "Cross-Internal Ring" inguinal oblique incision is a simple, safe, and reliable surgical method to treat pediatric IIH complicated with severe abdominal distension.

  13. Ionospheric heating with oblique high-frequency waves

    International Nuclear Information System (INIS)

    Field, E.C. Jr.; Bloom, R.M.; Kossey, P.A.

    1990-01-01

    This paper presents calculations of ionospheric electron temperature and density perturbations and ground-level signal changes produced by intense oblique high-frequency (HF) radio waves. The analysis takes into account focusing at caustics, the consequent Joule heating of the surrounding plasma, heat conduction, diffusion, and recombination processes, these being the effects of a powerful oblique modifying wave. It neglects whatever plasma instabilities might occur. The authors then seek effects on a secondary test wave that is propagated along the same path as the first. The calculations predict ground-level field strength reductions of several decibels in the test wave for modifying waves having effective radiated power (ERP) in the 85- to 90-dBW range. These field strength changes are similar in sign, magnitude, and location to ones measured in Soviet experiments. The location of the signal change is sensitive to the frequency and the model ionosphere assumed; so future experiments should employ the widest possible range of frequencies and propagation conditions. An ERP of 90 dBW seems to be a sort of threshold that, if exceeded, might result in substantial rather than small signal changes. The conclusions are based solely on Joule heating and subsequent refraction of waves passing through caustic regions

  14. Planar Elongation Measurements on Soft Elastomers

    DEFF Research Database (Denmark)

    Jensen, Mette Krog; Skov, Anne Ladegaard; Rasmussen, Henrik K.

    2009-01-01

    A new fixture to the filament stretch rheometer (FSR) has been developed to measure planar elongation of soft polymeric networks. To validate this new technique, soft polymeric networks of poly(propyleneoxide) (PPO) were investigated during deformation.......A new fixture to the filament stretch rheometer (FSR) has been developed to measure planar elongation of soft polymeric networks. To validate this new technique, soft polymeric networks of poly(propyleneoxide) (PPO) were investigated during deformation....

  15. Planar metasurface retroreflector

    Science.gov (United States)

    Arbabi, Amir; Arbabi, Ehsan; Horie, Yu; Kamali, Seyedeh Mahsa; Faraon, Andrei

    2017-07-01

    Metasurfaces are two-dimensional arrangements of subwavelength scatterers that control the propagation of optical waves. Here, we show that cascaded metasurfaces, each performing a predefined mathematical transformation, provide a new optical design framework that enables new functionalities not yet demonstrated with single metasurfaces. Specifically, we demonstrate that retroreflection can be achieved with two vertically stacked planar metasurfaces, the first performing a spatial Fourier transform and its inverse, and the second imparting a spatially varying momentum to the Fourier transform of the incident light. Using this concept, we fabricate and test a planar monolithic near-infrared retroreflector composed of two layers of silicon nanoposts, which reflects light along its incident direction with a normal incidence efficiency of 78% and a large half-power field of view of 60°. The metasurface retroreflector demonstrates the potential of cascaded metasurfaces for implementing novel high-performance components, and enables low-power and low-weight passive optical transmitters.

  16. Analysis of Torque Measurements on Films with Oblique Anistropy

    NARCIS (Netherlands)

    Abelmann, Leon; Kambersky, Vladimir; Lodder, J.C.; Popma, T.J.A.

    1993-01-01

    A measurement method is discussed to determine the magnetic anisotropy energy in a sample without assuming an a priori model for the origins of the anisotropy. The measurement procedure involves torque measurements in five different planes. Since it is especially useful for films with an oblique

  17. Design of a gait training device for control of pelvic obliquity.

    Science.gov (United States)

    Pietrusinski, Maciej; Severini, Giacomo; Cajigas, Iahn; Mavroidis, Constantinos; Bonato, Paolo

    2012-01-01

    This paper presents the design and testing of a novel device for the control of pelvic obliquity during gait. The device, called the Robotic Gait Rehabilitation (RGR) Trainer, consists of a single actuator system designed to target secondary gait deviations, such as hip-hiking, affecting the movement of the pelvis. Secondary gait deviations affecting the pelvis are generated in response to primary gait deviations (e.g. limited knee flexion during the swing phase) in stroke survivors and contribute to the overall asymmetrical gait pattern often observed in these patients. The proposed device generates a force field able to affect the obliquity of the pelvis (i.e. the rotation of the pelvis around the anteroposterior axis) by using an impedance controlled single linear actuator acting on a hip orthosis. Tests showed that the RGR Trainer is able to induce changes in pelvic obliquity trajectories (hip-hiking) in healthy subjects. These results suggest that the RGR Trainer is suitable to test the hypothesis that has motivated our efforts toward developing the system, namely that addressing both primary and secondary gait deviations during robotic-assisted gait training may help promote a physiologically-sound gait behavior more effectively than when only primary deviations are addressed.

  18. Morphological development of coasts at very oblique wave incidence

    DEFF Research Database (Denmark)

    Petersen, Dorthe Pia; Deigaard, Rolf; Fredsøe, Jørgen

    2003-01-01

    This study focuses on one distinct feature to be found on coasts exposed to a very oblique wave incidence, namely an accumulating spit. That is a spit where no retreat of the shoreline is going on along the spit. This requires a monotonically decreasing sediment transport capacity from the updrift...... that such a spit grows without changing its shape i.e. an equilibrium form emerge if the coast is exposed to a constant wave climate. During experiments conducted in a wave tank where a uniform stretch of coast was exposed to waves approaching at a very oblique angle an accumulating spit was formed at the down......-drift end of the coast. The spits approached equilibrium forms when constant wave climates were applied. The sediment transport around the spit has been investigated by two-dimensional models. The characteristic length scale for the equilibrium form depends linearly on the width of the surf zone...

  19. Chaotic non-planar vibrations of the thin elastica. Part I: Experimental observation of planar instability

    Science.gov (United States)

    Cusumano, J. P.; Moon, F. C.

    1995-01-01

    In this two-part paper, the results of an investigation into the non-linear dynamics of a flexible cantilevered rod (the elastica) with a thin rectangular cross-section are presented. An experimental examination of the dynamics of the elastica over a broad parameter range forms the core of Part I. In Part II, the experimental work is related to a theoretical study of the mechanics of the elastica, and the study of a two-degree-of-freedom model obtained by modal projection. The experimental system used in this investigation is a rod with clamped-free boundary conditions, forced by sinusoidally displacing the clamped end. Planar periodic motions of the driven elastica are shown to lose stability at distinct resonant wedges, and the resulting motions are shown in general to be non-planar, chaotic, bending-torsion oscillations. Non-planar motions in all resonances exhibit energy cascading and dynamic two-well phenomena, and a family of asymmetric, bending-torsion non-linear modes is discovered. Correlation dimension calculations are used to estimate the number of active degrees of freedom in the system.

  20. Computational Study on a PTAS for Planar Dominating Set Problem

    Directory of Open Access Journals (Sweden)

    Qian-Ping Gu

    2013-01-01

    Full Text Available The dominating set problem is a core NP-hard problem in combinatorial optimization and graph theory, and has many important applications. Baker [JACM 41,1994] introduces a k-outer planar graph decomposition-based framework for designing polynomial time approximation scheme (PTAS for a class of NP-hard problems in planar graphs. It is mentioned that the framework can be applied to obtain an O(2ckn time, c is a constant, (1+1/k-approximation algorithm for the planar dominating set problem. We show that the approximation ratio achieved by the mentioned application of the framework is not bounded by any constant for the planar dominating set problem. We modify the application of the framework to give a PTAS for the planar dominating set problem. With k-outer planar graph decompositions, the modified PTAS has an approximation ratio (1 + 2/k. Using 2k-outer planar graph decompositions, the modified PTAS achieves the approximation ratio (1+1/k in O(22ckn time. We report a computational study on the modified PTAS. Our results show that the modified PTAS is practical.

  1. Clinical evaluation of esophageal lymph flow system based on the RI uptake of removed regional lymph nodes following lymphoscintigraphy

    International Nuclear Information System (INIS)

    Tanabe, Gen; Baba, Masamichi; Kuroshima, Kazunao; Natugoe, Shouji; Yoshinaka, Heiji; Aikou, Takashi; Kajisa, Takashi

    1986-01-01

    For surgical treatment of esophageal cancer, the importance of evaluating lymph node metastasis and the lymph flow of the esophagus can not be overemphasized. In order to investigate the lymph flow of the esophagus, we preoperatively performed lymphoscintigraphy by endoscopic local injection of 99m Tc Renium Colloid into the esophageal wall in 42 esophageal cancer cases and 4 gastric cancer cases. Postoperatively, the RI uptake of each dissected regional lymph nodes was examined by a Scintillation Counter. The findings were as follows. 1. From the upper third of the thoracic esophagus, the main lymph flow was ascending to the neck and upper mediastinum. 2. From the middle third, the lymph flow was ascending to the neck and upper mediastinum and descending into the abdomen. 3. From the lower third, the main lymph flow was descending to the abdomen. In some cases, the lymph flow to the tracheal bifurcation nodes or to the lymph nodes around the left renal vein was observed. 4. In 61 % of the esophageal cancer cases with a partial bilateral neck dissection, the lymph flow to the bilateral supraclavicular lymph nodes was predominant compared to the upper mediastinum nodes. (author)

  2. Belief propagation and loop series on planar graphs

    International Nuclear Information System (INIS)

    Chertkov, Michael; Teodorescu, Razvan; Chernyak, Vladimir Y

    2008-01-01

    We discuss a generic model of Bayesian inference with binary variables defined on edges of a planar graph. The Loop Calculus approach of Chertkov and Chernyak (2006 Phys. Rev. E 73 065102(R) [cond-mat/0601487]; 2006 J. Stat. Mech. P06009 [cond-mat/0603189]) is used to evaluate the resulting series expansion for the partition function. We show that, for planar graphs, truncating the series at single-connected loops reduces, via a map reminiscent of the Fisher transformation (Fisher 1961 Phys. Rev. 124 1664), to evaluating the partition function of the dimer-matching model on an auxiliary planar graph. Thus, the truncated series can be easily re-summed, using the Pfaffian formula of Kasteleyn (1961 Physics 27 1209). This allows us to identify a big class of computationally tractable planar models reducible to a dimer model via the Belief Propagation (gauge) transformation. The Pfaffian representation can also be extended to the full Loop Series, in which case the expansion becomes a sum of Pfaffian contributions, each associated with dimer matchings on an extension to a subgraph of the original graph. Algorithmic consequences of the Pfaffian representation, as well as relations to quantum and non-planar models, are discussed

  3. A note on oblique water entry

    KAUST Repository

    Moore, M. R.

    2012-10-02

    A minor error in Howison et al. (J. Eng. Math. 48:321-337, 2004) obscured the fact that the points at which the free surface turns over in the solution of the Wagner model for the oblique impact of a two-dimensional body are directly related to the turnover points in the equivalent normal impact problem. This note corrects some of the earlier results given in Howison et al. (J. Eng. Math. 48:321-337, 2004) and discusses the implications for the applicability of the Wagner model. © 2012 Springer Science+Business Media B.V.

  4. Minimizing the translation error in the application of an oblique single-cut rotation osteotomy: Where to cut?

    NARCIS (Netherlands)

    Dobbe, Johannes G. G.; Strackee, Simon D.; Streekstra, Geert J.

    2017-01-01

    An oblique single cut rotation osteotomy enables correcting angular bone alignment in the coronal, sagittal and transverse planes, with just a single oblique osteotomy, and by rotating one bone segment in the osteotomy plane. However, translational malalignment is likely to exist if the bone is

  5. Planar quantum squeezing and atom interferometry

    Energy Technology Data Exchange (ETDEWEB)

    He, Q. Y.; Drummond, P. D.; Reid, M. D. [ARC Centre of Excellence for Quantum-Atom Optics, Centre for Atom Optics and Ultrafast Spectroscopy, Swinburne University of Technology, Melbourne 3122 (Australia); Peng Shiguo [Department of Physics, Tsinghua University, Beijing 100084 (China)

    2011-08-15

    We obtain a lower bound on the sum of two orthogonal spin component variances in a plane. This gives a planar uncertainty relation which holds even when the Heisenberg relation is not useful. We investigate the asymptotic, large-J limit and derive the properties of the planar quantum squeezed states that saturate this uncertainty relation. These states extend the concept of spin squeezing to any two conjugate spin directions. We show that planar quantum squeezing can be achieved experimentally as the ground state of a Bose-Einstein condensate in two coupled potential wells with a critical attractive interaction. These states reduce interferometric phase noise at all phase angles simultaneously. This is useful for one-shot interferometric phase measurements where the measured phase is completely unknown. Our results can also be used to derive entanglement criteria for multiple spins J at separated sites, with applications in quantum information.

  6. Oblique water entry of a three dimensional body

    Directory of Open Access Journals (Sweden)

    Scolan Yves-Marie

    2014-12-01

    Full Text Available The problem of the oblique water entry of a three dimensional body is considered. Wagner theory is the theoretical framework. Applications are discussed for an elliptic paraboloid entering an initially flat free surface. A dedicated experimental campaign yields a data base for comparisons. In the present analysis, pressure, force and dynamics of the wetted surface expansion are assessed.

  7. Searching for planar signatures in WMAP

    International Nuclear Information System (INIS)

    Abramo, L. Raul; Bernui, Armando; Pereira, Thiago S.

    2009-01-01

    We search for planar deviations of statistical isotropy in the Wilkinson Microwave Anisotropy Probe (WMAP) data by applying a recently introduced angular-planar statistics both to full-sky and to masked temperature maps, including in our analysis the effect of the residual foreground contamination and systematics in the foreground removing process as sources of error. We confirm earlier findings that full-sky maps exhibit anomalies at the planar (l) and angular (l) scales (l,l) = (2,5),(4,7), and (6,8), which seem to be due to unremoved foregrounds since this features are present in the full-sky map but not in the masked maps. On the other hand, our test detects slightly anomalous results at the scales (l,l) = (10,8) and (2,9) in the masked maps but not in the full-sky one, indicating that the foreground cleaning procedure (used to generate the full-sky map) could not only be creating false anomalies but also hiding existing ones. We also find a significant trace of an anomaly in the full-sky map at the scale (l,l) = (10,5), which is still present when we consider galactic cuts of 18.3% and 28.4%. As regards the quadrupole (l = 2), we find a coherent over-modulation over the whole celestial sphere, for all full-sky and cut-sky maps. Overall, our results seem to indicate that current CMB maps derived from WMAP data do not show significant signs of anisotropies, as measured by our angular-planar estimator. However, we have detected a curious coherence of planar modulations at angular scales of the order of the galaxy's plane, which may be an indication of residual contaminations in the full- and cut-sky maps

  8. The Role of Rift Obliquity in Formation of the Gulf of California

    Science.gov (United States)

    Bennett, Scott Edmund Kelsey

    The Gulf of California illustrates how highly oblique rift geometries, where transform faults are kinematically linked to large-offset normal faults in adjacent pull-apart basins, enhance the ability of continental lithosphere to rupture and, ultimately, hasten the formation of new oceanic basins. The Gulf of California rift has accommodated oblique divergence of the Pacific and North America tectonic plates in northwestern Mexico since Miocene time. Due to its infancy, the rifted margins of the Gulf of California preserve a rare onshore record of early continental break-up processes from which to investigate the role of rift obliquity in strain localization. Using new high-precision paleomagnetic vectors from tectonically stable sites in north-central Baja California, I compile a paleomagnetic transect of Miocene ignimbrites across northern Baja California and Sonora that reveals the timing and distribution of dextral shear associated with inception of this oblique rift. I integrate detailed geologic mapping, basin analysis, and geochronology of pre-rift and syn-rift volcanic units to determine the timing of fault activity on Isla Tiburon, a proximal onshore exposure of the rifted North America margin, adjacent to the axis of the Gulf of California. The onset of strike-slip faulting on Isla Tiburon, ca. 8 - 7 Ma, was synchronous with the onset of transform faulting along a significant length of the nascent plate boundary within the rift. This tectonic transition coincides with a clockwise azimuthal shift in Pacific-North America relative motion that increased rift obliquity. I constrain the earliest marine conditions on southwest Isla Tiburon to ca. 6.4 - 6.0 Ma, coincident with a regional latest Miocene marine incursion in the northern proto-Gulf of California. This event likely flooded a narrow, incipient topographic depression along a ˜650 km-long portion of the latest Miocene plate boundary and corresponds in time and space with formation of a newly

  9. Photoinjector beam quality improvement by shaping the wavefront of a drive laser with oblique incidence

    International Nuclear Information System (INIS)

    He Zhigang; Wang Xiaohui; Jia Qika

    2012-01-01

    To increase the quantum efficiency (QE) of a copper photocathode and reduce the thermal emittance of an electron beam, a drive laser with oblique incidence was adopted in a BNL type photocathode rf gun. The disadvantageous effects on the beam quality caused by oblique incidence were analyzed qualitatively. A simple way to solve the problems through wavefront shaping was introduced and the beam quality was improved. (authors)

  10. Oblique electron cyclotron emission for electron distribution studies (invited)

    International Nuclear Information System (INIS)

    Preische, S.; Efthimion, P.C.; Kaye, S.M.

    1997-01-01

    Electron cyclotron emission (ECE) at an oblique angle to the magnetic field provides a means of probing the electron distribution function both in energy and physical space through changes in and constraints on the relativistic electron cyclotron resonance condition. Diagnostics based on this Doppler shifted resonance are able to study a variety of electron distributions through changes in the location of the resonance in physical or energy space accomplished by changes in the viewing angle and frequency, and the magnetic field. For the case of observation across a changing magnetic field, such as across the tokamak midplane, the constraint on the resonance condition for real solutions to the dispersion relation can constrain the physical location of optically thin emission. A new Oblique ECE diagnostic was installed and operated on the PBX-M tokamak for the study of energetic electrons during lower hybrid current drive. It has a view 33 degree with respect to perpendicular in the tokamak midplane, receives second harmonic X-mode emission, and is constrained to receive single pass emission by SiC viewing dumps on the tokamak walls. Spatial localization of optically thin emission from superthermal electrons (50 endash 100 keV) was obtained by observation of emission upshifted from a thermal cyclotron harmonic. The localized measurements of the electron energy distribution and the superthermal density profile made by this diagnostic demonstrate its potential to study the spatial transport of energetic electrons on fast magnetohydrodynamic time scales or anomalous diffusion time scales. Oblique ECE can also be used to study electron distributions that may have a slight deviation from a Maxwellian by localizing the emission in energy space. (Abstract Truncated)

  11. Surgical treatment of superior oblique palsy: Predictors of outcome

    Directory of Open Access Journals (Sweden)

    Pilar Merino Sanz

    2017-01-01

    Full Text Available Purpose: The purpose of this study was to evaluate the incidence and outcome of surgically treated superior oblique palsy (SOP and the factors involved in its resolution. Methods: We performed a retrospective study of 76 patients who underwent surgery for SOP. We recorded data from the physical examination and the number and type of procedures performed. Favorable outcome was defined as resolution of or improvement in torticollis (≤5° and diplopia in primary position (PP and downgaze or as vertical deviation (VD <5 prism diopters (pd in PP and 10 pd in the oblique diagnostic position. Results: Mean age was 33.12 years. Congenital SOP was the most frequent type (65.8%. Mean preoperative VD was 15.89 ± 9.94 pd, decreasing to 3.07 ± 4.36 pd after surgery. Associated horizontal deviation was recorded in 51.32% of cases. The mean number of procedures was 1.37 ± 0.62 (range 1–4, with 69.7% of patients requiring only one procedure. The mean number of muscles operated on was 1.96 ± 1.01 (inferior oblique being the most frequent. A greater reduction in VD after surgery was observed in patients with congenital SOP (P = 0.04. Although none of the factors evaluated influenced surgical outcome, amblyopic patients had a greater risk of reoperation (P = 0.04. A favorable outcome was achieved in 75% of cases. Mean follow-up was 37.08 months. Conclusion: Congenital SOP was twice as frequent as acquired SOP and although surgery was successful in most cases, a greater reduction in VD was obtained in congenital cases. Amblyopia was identified as a risk factor for reoperation.

  12. Substrate and coating defect planarization strategies for high-laser-fluence multilayer mirrors

    International Nuclear Information System (INIS)

    Stolz, Christopher J.; Wolfe, Justin E.; Mirkarimi, Paul B.; Folta, James A.; Adams, John J.; Menor, Marlon G.; Teslich, Nick E.; Soufli, Regina; Menoni, Carmen S.; Patel, Dinesh

    2015-01-01

    Planarizing or smoothing over nodular defects in multilayer mirrors can be accomplished by a discrete deposit-and-etch process that exploits the angle-dependent etching rate of optical materials. Typically, nodular defects limit the fluence on mirrors irradiated at 1064 nm with 10 ns pulse lengths due to geometrically- and interference-induced light intensification. Planarized hafina/silica multilayer mirrors have demonstrated > 125 J/cm 2 laser resistance for single-shot testing and 50 J/cm 2 for multi-shot testing for nodular defects originating on the substrate surface. Two planarization methods were explored: thick planarization layers on the substrate surface and planarized silica layers throughout the multilayer in which only the silica layers that are below one half of the incoming electric field value are etched. This paper also describes the impact of planarized defects that are buried within the multilayer structure compared to planarized substrate particulate defects. - Highlights: • Defect planarization significantly improves multilayer mirror laser resistance • Substrate and coating defects have both been effectively planarized • Single and multishot laser resistance improvement was demonstrated

  13. Researching on Real 3d Modeling Constructed with the Oblique Photogrammetry and Terrestrial Photogrammetry

    Science.gov (United States)

    Han, Youmei; Jiao, Minglian; Shijuan

    2018-04-01

    With the rapid development of the oblique photogrammetry, many cities have built some real 3D model with this technology. Although it has the advantages of short period, high efficiency and good air angle effect, the near ground view angle of these real 3D models are not very good. With increasing development of smart cities, the requirements of reality, practicality and accuracy on real 3D models are becoming higher. How to produce and improve the real 3D models quickly has become one of the hot research directions of geospatial information. To meet this requirement In this paper, Combined with the characteristics of current oblique photogrammetry modeling and the terrestrial photogrammetry, we proposed a new technological process, which consists of close range sensor design, data acquisition and processing. The proposed method is being tested by using oblique photography images acquired. The results confirm the effectiveness of the proposed approach.

  14. A computational study on oblique shock wave-turbulent boundary layer interaction

    Science.gov (United States)

    Joy, Md. Saddam Hossain; Rahman, Saeedur; Hasan, A. B. M. Toufique; Ali, M.; Mitsutake, Y.; Matsuo, S.; Setoguchi, T.

    2016-07-01

    A numerical computation of an oblique shock wave incident on a turbulent boundary layer was performed for free stream flow of air at M∞ = 2.0 and Re1 = 10.5×106 m-1. The oblique shock wave was generated from a 8° wedge. Reynolds averaged Navier-Stokes (RANS) simulation with k-ω SST turbulence model was first utilized for two dimensional (2D) steady case. The results were compared with the experiment at the same flow conditions. Further, to capture the unsteadiness, a 2D Large Eddy Simulation (LES) with sub-grid scale model WMLES was performed which showed the unsteady effects. The frequency of the shock oscillation was computed and was found to be comparable with that of experimental measurement.

  15. Reliability of internal oblique elbow radiographs for measuring displacement of medial epicondyle humerus fractures: a cadaveric study.

    Science.gov (United States)

    Gottschalk, Hilton P; Bastrom, Tracey P; Edmonds, Eric W

    2013-01-01

    Standard elbow radiographs (AP and lateral views) are not accurate enough to measure true displacement of medial epicondyle fractures of the humerus. The amount of perceived displacement has been used to determine treatment options. This study assesses the utility of internal oblique radiographs for measurement of true displacement in these fractures. A medial epicondyle fracture was created in a cadaveric specimen. Displacement of the fragment (mm) was set at 5, 10, and 15 in line with the vector of the flexor pronator mass. The fragment was sutured temporarily in place. Radiographs were obtained at 0 (AP), 15, 30, 45, 60, 75, and 90 degrees (lateral) of internal rotation, with the elbow in set positions of flexion. This was done with and without radio-opaque markers placed on the fragment and fracture bed. The 45 and 60 degrees internal oblique radiographs were then presented to 5 separate reviewers (of different levels of training) to evaluate intraobserver and interobserver agreement. Change in elbow position did not affect the perceived displacement (P=0.82) with excellent intraobserver reliability (intraclass correlation coefficient range, 0.979 to 0.988) and interobserver agreement of 0.953. The intraclass correlation coefficient for intraobserver reliability on 45 degrees internal oblique films for all groups ranged from 0.985 to 0.998, with interobserver agreement of 0.953. For predicting displacement, the observers were 60% accurate in predicting the true displacement on the 45 degrees internal oblique films and only 35% accurate using the 60 degrees internal oblique view. Standardizing to a 45 degrees internal oblique radiograph of the elbow (regardless of elbow flexion) can augment the treating surgeon's ability to determine true displacement. At this degree of rotation, the measured number can be multiplied by 1.4 to better estimate displacement. The addition of a 45 degrees internal oblique radiograph in medial humeral epicondyle fractures has good

  16. Beyond level planarity

    NARCIS (Netherlands)

    Angelini, P.; Da Lozzo, G.; Di Battista, G.; Frati, F.; Patrignani, M.; Rutter, I.; Hu, Y.; Nöllenburg, M.

    2016-01-01

    In this paper we settle the computational complexity of two open problems related to the extension of the notion of level planarity to surfaces different from the plane. Namely, we show that the problems of testing the existence of a level embedding of a level graph on the surface of the rolling

  17. Kinetic Alfven waves and electron physics. II. Oblique slow shocks

    International Nuclear Information System (INIS)

    Yin, L.; Winske, D.; Daughton, W.

    2007-01-01

    One-dimensional (1D) particle-in-cell (PIC; kinetic ions and electrons) and hybrid (kinetic ions; adiabatic and massless fluid electrons) simulations of highly oblique slow shocks (θ Bn =84 deg. and β=0.1) [Yin et al., J. Geophys. Res., 110, A09217 (2005)] have shown that the dissipation from the ions is too weak to form a shock and that kinetic electron physics is required. The PIC simulations also showed that the downstream electron temperature becomes anisotropic (T e parallel )>T e perpendicular ), as observed in slow shocks in space. The electron anisotropy results, in part, from the electron acceleration/heating by parallel electric fields of obliquely propagating kinetic Alfven waves (KAWs) excited by ion-ion streaming, which cannot be modeled accurately in hybrid simulations. In the shock ramp, spiky structures occur in density and electron parallel temperature, where the ion parallel temperature decreases due to the reduction of the ion backstreaming speed. In this paper, KAW and electron physics in oblique slow shocks are further examined under lower electron beta conditions. It is found that as the electron beta is reduced, the resonant interaction between electrons and the wave parallel electric fields shifts to the tail of the electron velocity distribution, providing more efficient parallel heating. As a consequence, for β e =0.02, the electron physics is shown to influence the formation of a θ Bn =75 deg. shock. Electron effects are further enhanced at a more oblique shock angle (θ Bn =84 deg.) when both the growth rate and the range of unstable modes on the KAW branch increase. Small-scale electron and ion phase-space vortices in the shock ramp formed by electron-KAW interactions and the reduction of the ion backstreaming speed, respectively, are observed in the simulations and confirmed in homogeneous geometries in one and two spatial dimensions in the accompanying paper [Yin et al., Phys. Plasmas 14, 062104 (2007)]. Results from this study

  18. Evaluation of cardiac function using multi-shot echo planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi; Tanitame, Nobuko; Hata, Ryoichiro; Hirai, Nobuhiko; Ikeda, Midori; Ono, Chiaki; Fukuoka, Haruhito; Ito, Katsuhide [Hiroshima Univ. (Japan). School of Medicine

    1998-01-01

    In this study, we performed multi-shot echo planar imaging (8 shot, TR/TE/FL=55 ms/18 ms/60 degrees) and k-space segmented fast gradient echo sequence (8 views per segment, TR/TE/FL=9.9 ms/1.8 ms/30 degrees) to assess cardiac function in healthy volunteers. Transaxial sections of the entire heart were obtained with both sequences in ECG triggered, breath hold, and with a 256 x 128 matrix. Resulting temporal resolution was 55 ms for echo planar imaging, and 71 ms for k-space segmented fast gradient echo sequence, respectively. Ventricular volume and ejection fraction of both ventricles and left ventricular mass obtained with multi-shot echo planar imaging were assessed in comparison with k-space segmented fast gradient echo sequence. Measurements of left ventricular volume, ejection fraction and mass obtained with multi-shot echo planar imaging demonstrated close correlation with those obtained with k-space segmented fast gradient echo sequence. Right ventricular volumes obtained with echo planar imaging were significantly higher than those obtained with k-space segmented fast gradient echo sequence. This tendency is considered to be due to differing contrast between right ventricular myocardium and fat tissue observed with echo planar imaging relative to that observed with fast gradient echo sequence, because fat suppression is always performed in echo planar images. Multi-shot echo planar imaging can be a reliable tool for measurement of cardiac functional parameters, although wall motion analysis of the left ventricle requires higher temporal resolution and a short axial section. (K.H.)

  19. Oblique-Length Contraction Factor in the Special Theory of Relativity

    Directory of Open Access Journals (Sweden)

    Smarandache F.

    2013-01-01

    Full Text Available In this paper one generalizes the Lorentz Contraction Factor for the case when the lengths are moving at an oblique angle with respect to the motion direction. One shows that the angles of the moving relativistic objects are distorted.

  20. Oblique abdominal muscle activity in response to external perturbations when pushing a cart.

    Science.gov (United States)

    Lee, Yun-Ju; Hoozemans, Marco J M; van Dieën, Jaap H

    2010-05-07

    Cyclic activation of the external and internal oblique muscles contributes to twisting moments during normal gait. During pushing while walking, it is not well understood how these muscles respond to presence of predictable (cyclic push-off forces) and unpredictable (external) perturbations that occur in pushing tasks. We hypothesized that the predictable perturbations due to the cyclic push-off forces would be associated with cyclic muscle activity, while external perturbations would be counteracted by cocontraction of the oblique abdominal muscles. Eight healthy male subjects pushed at two target forces and two handle heights in a static condition and while walking without and with external perturbations. For all pushing tasks, the median, the static (10th percentile) and the peak levels (90th percentile) of the electromyographic amplitudes were determined. Linear models with oblique abdominal EMGs and trunk angles as input were fit to the twisting moments, to estimate trunk stiffness. There was no significant difference between the static EMG levels in pushing while walking compared to the peak levels in pushing while standing. When pushing while walking, the additional dynamic activity was associated with the twisting moments, which were actively modulated by the pairs of oblique muscles as in normal gait. The median and static levels of trunk muscle activity and estimated trunk stiffness were significantly higher when perturbations occurred than without perturbations. The increase baseline of muscle activity indicated cocontraction of the antagonistic muscle pairs. Furthermore, this cocontraction resulted in an increased trunk stiffness around the longitudinal axis. Copyright 2010 Elsevier Ltd. All rights reserved.

  1. RESEARCHING ON REAL 3D MODELING CONSTRUCTED WITH THE OBLIQUE PHOTOGRAMMETRY AND TERRESTRIAL PHOTOGRAMMETRY

    Directory of Open Access Journals (Sweden)

    Y. Han

    2018-04-01

    Full Text Available With the rapid development of the oblique photogrammetry, many cities have built some real 3D model with this technology. Although it has the advantages of short period, high efficiency and good air angle effect, the near ground view angle of these real 3D models are not very good. With increasing development of smart cities, the requirements of reality, practicality and accuracy on real 3D models are becoming higher. How to produce and improve the real 3D models quickly has become one of the hot research directions of geospatial information. To meet this requirement In this paper, Combined with the characteristics of current oblique photogrammetry modeling and the terrestrial photogrammetry, we proposed a new technological process, which consists of close range sensor design, data acquisition and processing. The proposed method is being tested by using oblique photography images acquired. The results confirm the effectiveness of the proposed approach.

  2. Generators for finite depth subfactor planar algebras

    Indian Academy of Sciences (India)

    The main result of Kodiyalam and Tupurani [3] shows that a subfactor planar algebra of finite depth is singly generated with a finite presentation. If P is a subfactor planar algebra of depth k, it is shown there that a single 2k-box generates P. It is natural to ask what the smallest s is such that a single s-box generates P. While ...

  3. Numerical simulation of hydrodynamic performance of ship under oblique conditions

    Directory of Open Access Journals (Sweden)

    CHEN Zhiming

    2018-02-01

    Full Text Available [Objectives] This paper is intended to study the viscous flow field around a ship under oblique conditions and provide a research basis for ship maneuverability. [Methods] Using commercial software STRA-CCM+, the SST k-ω turbulence model is selected to predict the hydrodynamic performance of the KVLCC2 model at different drift angles, and predict the hull flow field. The pressure distribution of the ship model at different drift angles is observed and the vortex shedding of the ship's hull and constraint streamlines on the hull's surface are also observed. [Results] The results show that numerical simulation can satisfy the demands of engineering application in the prediction of the lateral force, yaw moment and hull surface pressure distribution of a ship. [Conclusions] The research results of this paper can provide valuable references for the study of the flow separation phenomenon under oblique conditions.

  4. The Martian polar caps: Stability and water transport at low obliquities

    Science.gov (United States)

    Henderson, B. G.; Jakosky, B. M.

    1992-01-01

    The seasonal cycle of water on Mars is regulated by the two polar caps. In the winter hemisphere, the seasonal CO2 deposits at a temperature near 150 K acts as a cold trap to remove water vapor from the atmosphere. When summer returns, water is pumped back into the atmosphere by a number of mechanisms, including release from the receding CO2 frost, diffusion from the polar regolith, and sublimation from a water-ice residual cap. These processes drive an exchange of water vapor between the polar caps that helps shape the Martian climate. Thus, understanding the behavior of the polar caps is important for interpreting the Martian climate both now and at other epochs. Mars' obliquity undergoes large variations over large time scales. As the obliquity decreases, the poles receive less solar energy so that more CO2 condenses from the atmosphere onto the poles. It has been suggested that permanent CO2 condenses from the atmosphere onto the poles. It has been suggested that permanent CO2 caps might form at the poles in response to a feedback mechanism existing between the polar cap albedo, the CO2 pressure, and the dust storm frequency. The year-round presence of the CO2 deposits would effectively dry out the atmosphere, while diffusion of water from the regolith would be the only source of water vapor to the atmosphere. We have reviewed the CO2 balance at low obliquity taking into account the asymmetries which make the north and south hemispheres different. Our analysis linked with a numerical model of the polar caps leads us to believe that one summertime cap will always lose its CO2 cover during a Martian year, although we cannot predict which cap this will be. We conclude that significant amounts of water vapor will sublime from the exposed cap during summer, and the Martian atmosphere will support an active water cycle even at low obliquity.

  5. Diffractive axicons in oblique illumination: analysis and experiments and comparison with elliptical axicons.

    Science.gov (United States)

    Thaning, Anna; Jaroszewicz, Zbigniew; Friberg, Ari T

    2003-01-01

    Axicons in oblique illumination produce broadened focal lines, a problem, e.g., in scanning applications. A compact mathematical description of the focal segment is presented, for the first time, to our knowledge, and the results are compared with elliptical axicons in normal illumination. In both cases, analytical expressions in the form of asteroid curves are obtained from asymptotic wave theory and caustic surfaces. The results are confirmed by direct diffraction simulations and by experiments. In addition we show that at a fixed angle an elliptical axicon can be used to compensate for the adverse effects of oblique illumination.

  6. Evanescent field refractometry in planar optical fiber.

    Science.gov (United States)

    Holmes, Christopher; Jantzen, Alexander; Gray, Alan C; Gow, Paul C; Carpenter, Lewis G; Bannerman, Rex H S; Gates, James C; Smith, Peter G R

    2018-02-15

    This Letter demonstrates a refractometer in integrated optical fiber, a new optical platform that planarizes fiber using flame hydrolysis deposition (FHD). The unique advantage of the technology is survivability in harsh environments. The platform is mechanically robust, and can survive elevated temperatures approaching 1000°C and exposure to common solvents, including acetone, gasoline, and methanol. For the demonstrated refractometer, fabrication was achieved through wet etching an SMF-28 fiber to a diameter of 8 μm before FHD planarization. An external refractive index was monitored using fiber Bragg gratings (FBGs), written into the core of the planarized fiber. A direct comparison to alternative FBG refractometers is made, for which the developed platform is shown to have comparable sensitivity, with the added advantage of survivability in harsh environments.

  7. Oblique rift opening revealed by reoccurring magma injection in central Iceland

    KAUST Repository

    Ruch, Joel

    2016-08-05

    Extension deficit builds up over centuries at divergent plate boundaries and is recurrently removed during rifting events, accompanied by magma intrusions and transient metre-scale deformation. However, information on transient near-field deformation has rarely been captured, hindering progress in understanding rifting mechanisms and evolution. Here we show new evidence of oblique rift opening during a rifting event influenced by pre-existing fractures and two centuries of extension deficit accumulation. This event originated from the Bárðarbunga caldera and led to the largest basaltic eruption in Iceland in >200 years. The results show that the opening was initially accompanied by left-lateral shear that ceased with increasing opening. Our results imply that pre-existing fractures play a key role in controlling oblique rift opening at divergent plate boundaries.

  8. Spectroscopic ellipsometry investigations of optical anisotropy in obliquely deposited hafnia thin films

    Energy Technology Data Exchange (ETDEWEB)

    Tokas, R. B., E-mail: tokasstar@gmail.com; Jena, Shuvendu; Thakur, S.; Sahoo, N. K. [Atomic & Molecular Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai-85 (India); Haque, S. Maidul; Rao, K. Divakar [Photonics & Nanotechnology Section, Atomic & Molecular Physics Division, Bhabha Atomic Research Centre facility, Visakhapatnam-530012 (India)

    2016-05-23

    In present work, HfO{sub 2} thin films have been deposited at various oblique incidences on Si substrates by electron beam evaporation. These refractory oxide films exhibited anisotropy in refractive index predictably due to special columnar microstructure. Spectroscopic ellipsometry being a powerful tool for optical characterization has been employed to investigate optical anisotropy. It was observed that the film deposited at glancing angle (80°) exhibits the highest optical anisotropy. Further, anisotropy was noticed to decrease with lower values of deposition angles while effective refractive index depicts opposite trend. Variation in refractive index and anisotropy has been explained in light of atomic shadowing during growth of thin films at oblique angles.

  9. Nonlinear Saturation Amplitude in Classical Planar Richtmyer–Meshkov Instability

    International Nuclear Information System (INIS)

    Liu Wan-Hai; Jiang Hong-Bin; Ma Wen-Fang; Wang Xiang

    2016-01-01

    The classical planar Richtmyer–Meshkov instability (RMI) at a fluid interface supported by a constant pressure is investigated by a formal perturbation expansion up to the third order, and then according to definition of nonlinear saturation amplitude (NSA) in Rayleigh–Taylor instability (RTI), the NSA in planar RMI is obtained explicitly. It is found that the NSA in planar RMI is affected by the initial perturbation wavelength and the initial amplitude of the interface, while the effect of the initial amplitude of the interface on the NSA is less than that of the initial perturbation wavelength. Without marginal influence of the initial amplitude, the NSA increases linearly with wavelength. The NSA normalized by the wavelength in planar RMI is about 0.11, larger than that corresponding to RTI. (paper)

  10. Intrinsic carpal ligaments on MR and multidetector CT arthrography: comparison of axial and axial oblique planes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Griffith, James F.; Ng, Alex W.H.; Law, Eric K.C. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Hong Kong (China); Tse, W.L.; Wong, Clara W.Y.; Ho, P.C. [The Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince Of Wales Hospital, Hong Kong (China)

    2017-03-15

    To compare axial and oblique axial planes on MR arthrography (MRA) and multidetector CT arthrography (CTA) to evaluate dorsal and volar parts of scapholunate (SLIL) and lunotriquetral interosseous (LTIL) ligaments. Nine cadaveric wrists of five male subjects were studied. The visibility of dorsal and volar parts of the SLIL and LTIL was graded semi-quantitatively (good, intermediate, poor) on MRA and CTA. The presence of a ligament tear was determined on arthrosocopy and sensitivity, specificity and accuracy of tear detection were calculated. Oblique axial imaging was particularly useful for delineating dorsal and volar parts of the LTIL on MRA with overall 'good' visibility increased from 11 % to 78 %. The accuracy of MRA and CTA in revealing SLIL and LTIL tear was higher using the oblique axial plane. The overall accuracy for detecting SLIL tear on CTA improved from 94 % to 100 % and from 89 % to 94 % on MRA; the overall accuracy of detecting LTIL tear on CTA improved from 89 % to 100 % and from 72 % to 89 % on MRA Oblique axial imaging during CT and MR arthrography improves detection of tears in the dorsal and volar parts of both SLIL and LTIL. (orig.)

  11. The peeling process of infinite Boltzmann planar maps

    DEFF Research Database (Denmark)

    Budd, Timothy George

    2016-01-01

    criterion has a very simple interpretation. The finite random planar maps under consideration were recently proved to possess a well-defined local limit known as the infinite Boltzmann planar map (IBPM). Inspired by recent work of Curien and Le Gall, we show that the peeling process on the IBPM can...

  12. Planar dynamical systems selected classical problems

    CERN Document Server

    Liu, Yirong; Huang, Wentao

    2014-01-01

    This book presents in an elementary way the recent significant developments in the qualitative theory of planar dynamical systems. The subjects are covered as follows: the studies of center and isochronous center problems, multiple Hopf bifurcations and local and global bifurcations of the equivariant planar vector fields which concern with Hilbert's 16th problem. This book is intended for graduate students, post-doctors and researchers in the area of theories and applications of dynamical systems. For all engineers who are interested the theory of dynamical systems, it is also a reasona

  13. Ion-damage-free planarization or shallow angle sectioning of solar cells for mapping grain orientation and nanoscale photovoltaic properties

    Science.gov (United States)

    Kutes, Yasemin; Luria, Justin; Sun, Yu; Moore, Andrew; Aguirre, Brandon A.; Cruz-Campa, Jose L.; Aindow, Mark; Zubia, David; Huey, Bryan D.

    2017-05-01

    Ion beam milling is the most common modern method for preparing specific features for microscopic analysis, even though concomitant ion implantation and amorphization remain persistent challenges, particularly as they often modify materials properties of interest. Atomic force microscopy (AFM), on the other hand, can mechanically mill specific nanoscale regions in plan-view without chemical or high energy ion damage, due to its resolution, directionality, and fine load control. As an example, AFM-nanomilling (AFM-NM) is implemented for top-down planarization of polycrystalline CdTe thin film solar cells, with a resulting decrease in the root mean square (RMS) roughness by an order of magnitude, even better than for a low incidence FIB polished surface. Subsequent AFM-based property maps reveal a substantially stronger contrast, in this case of the short-circuit current or open circuit voltage during light exposure. Electron back scattering diffraction (EBSD) imaging also becomes possible upon AFM-NM, enabling direct correlations between the local materials properties and the polycrystalline microstructure. Smooth shallow-angle cross-sections are demonstrated as well, based on targeted oblique milling. As expected, this reveals a gradual decrease in the average short-circuit current and maximum power as the underlying CdS and electrode layers are approached, but a relatively consistent open-circuit voltage through the diminishing thickness of the CdTe absorber. AFM-based nanomilling is therefore a powerful tool for material characterization, uniquely providing ion-damage free, selective area, planar smoothing or low-angle sectioning of specimens while preserving their functionality. This enables novel, co-located advanced AFM measurements, EBSD analysis, and investigations by related techniques that are otherwise hindered by surface morphology or surface damage.

  14. Current in heavy-current planar diode with discrete emission surface

    International Nuclear Information System (INIS)

    Belomyttsev, S.Ya.; Korovin, S.D.; Pegel', I.V

    1999-01-01

    Dependence of current in a high-current planar diode on the size of emission centres was studied. Essential effect of emission surface microstructure on the current value in the planar diode was demonstrated. It was determined that if the distance between the emitter essentially exceeded their size then current dependence on the ratio of size to the value of the diode gap was an exponential function with 3/2 index. Current dependence on voltage obeyed the exponential law with 3/2 index up to higher voltage values in the planar diode with discrete emission surface in contrast to the case of a planar diode with homogeneous emission surface [ru

  15. Dynamic magnetization of NiZn ferrite doped FeSiAl thin films fabricated by oblique sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Xiaoxi, E-mail: xiaoxi.zhong@gmail.com [Sichuan Province Key Laboratory of Information Materials and Devices Application, Chengdu University of Information Technology, Chengdu 610225 (China); Phuoc, Nguyen N. [Temasek Laboratories, National University of Singapore, 5A Engineering Drive 2, Singapore 117411 (Singapore); Soh, Wee Tee [Center for Superconducting and Magnetic Materials, Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117542 (Singapore); Ong, C.K. [Temasek Laboratories, National University of Singapore, 5A Engineering Drive 2, Singapore 117411 (Singapore); Center for Superconducting and Magnetic Materials, Department of Physics, National University of Singapore, 2 Science Drive 3, Singapore 117542 (Singapore); Li, Lezhong [Sichuan Province Key Laboratory of Information Materials and Devices Application, Chengdu University of Information Technology, Chengdu 610225 (China)

    2017-06-15

    Highlights: • We prepared NiZn ferrite doped FeSiAl-based thin films using oblique deposition technique. • The magnetic properties of FeSiAl-based thin films were systematically studied. • Two ferromagnetic resonance peaks were observed in the permeability spectra. • The thermal stability of microwave properties of FeSiAl-based films was studied. • The thermal stability of properties we studied was relatively good. - Abstract: In this study, we comprehensively investigate the dynamic magnetic properties of FeSiAl-NiZnFeO thin films prepared by the oblique deposition method via a shorted microstrip perturbation technique. For the films with higher oblique angle and NiZn ferrite doping amount, there are two ferromagnetic resonance peaks observed in the permeability spectra, and both of the two peaks originate from FeSiAl. Furthermore, the magnetic anisotropy field H{sub K} of the ferromagnetic resonance peak at higher frequency is enhanced with increasing doping amount, which is interpreted in terms of the contribution of reinforced stress-induced anisotropy and shape anisotropy brought about by doping elements and oblique sputtering method. In addition, the thermal stability of the ferromagnetic resonance frequency f{sub FMR} of FeSiAl-NiZnFeO films with oblique angles of 35° and 45° with respect to temperature ranging from 300 K to 420 K is deteriorated with increasing ferrite doping amount, which is mainly ascribed to the influence of pair-ordering anisotropy and/or the reduction of the FeSiAl grain size.

  16. Investigation on hydrodynamic performance of a marine propeller in oblique flow by RANS computations

    Directory of Open Access Journals (Sweden)

    Jianxi Yao

    2015-01-01

    Full Text Available This paper presents a numerical study on investigating on hydrodynamic characteristics of a marine propeller in oblique flow. The study is achieved by RANS simulations on an open source platform - OpenFOAM. A sliding grid approach is applied to compute the rotating motion of the propeller. Total force and moment acting on blades, as well as average force distributions in one revolution on propeller disk, are obtained for 70 cases of com- binations of advance ratios and oblique angles. The computed results are compared with available experimental data and discussed.

  17. Control of a three-dimensional turbulent shear layer by means of oblique vortices

    Science.gov (United States)

    Jürgens, Werner; Kaltenbach, Hans-Jakob

    2018-04-01

    The effect of local forcing on the separated, three-dimensional shear layer downstream of a backward-facing step is investigated by means of large-eddy simulation for a Reynolds number based on the step height of 10,700. The step edge is either oriented normal to the approaching turbulent boundary layer or swept at an angle of 40°. Oblique vortices with different orientation and spacing are generated by wavelike suction and blowing of fluid through an edge parallel slot. The vortices exhibit a complex three-dimensional structure, but they can be characterized by a wavevector in a horizontal section plane. In order to determine the step-normal component of the wavevector, a method is developed based on phase averages. The dependence of the wavevector on the forcing parameters can be described in terms of a dispersion relation, the structure of which indicates that the disturbances are mainly convected through the fluid. The introduced vortices reduce the size of the recirculation region by up to 38%. In both the planar and the swept case, the most efficient of the studied forcings consists of vortices which propagate in a direction that deviates by more than 50° from the step normal. These vortices exhibit a spacing in the order of 2.5 step heights. The upstream shift of the reattachment line can be explained by increased mixing and momentum transport inside the shear layer which is reflected in high levels of the Reynolds shear stress -ρ \\overline{u'v'}. The position of the maximum of the coherent shear stress is found to depend linearly on the wavelength, similar to two-dimensional free shear layers.

  18. Asymmetric growth of collapsed caldera by oblique subsidence during the 2000 eruption of Miyakejima, Japan

    Science.gov (United States)

    Geshi, Nobuo

    2009-04-01

    Oblique development of the ring faults reflecting the structural heterogeneities inside the volcano formed many asymmetric structures of Miyakejima 2000 AD caldera. The asymmetry includes (a) offset location of the ring faults with respect to the associated shallow magma chamber, (b) unequal outward migration of the caldera wall 600 m at the southeastern rim but only 200 m at the northwestern rim, (c) development of tilted terrace only at the southeastern caldera margin, (d) eruption sites and fumaroles being confined to the southern part of the caldera. Geophysical data, including ground deformation and seismic activity, indicates the offset of the location of the magma chamber about 2 km south of the caldera center on the surface. The ring faults propagated from the deflating magma chamber obliquely about 30 degrees toward the summit. The oblique subsidence of the cylindrical block formed a wider instable zone, particularly in the southeastern side of the ring fault that enhanced the larger outward migration of the caldera rim and also caused the formation of the outer half-ring fault bordering the tilting slope at the southern part. Ascending pass of the buoyant magma along the tilted ring faults was concentrated in the southern half of the caldera and consequently the distributions of the eruption sites and fumaroles are localized in the southern-half part of the caldera. The structure of the Miyakejima 2000 caldera with complete development of the ring faults, its high roof aspect ratio and oblique subsidence is clearly distinguishable from trapdoor-type caldera. The oblique development of the ring faults can be controlled by the mechanical contrast between the solidified conduits and surrounding fragile volcanic edifice. Asymmetric development of the Miyakejima caldera shows that the collapsed calderas are potential indicators of the heterogeneous structures inside of the volcano, particularly in the case of small-size caldera.

  19. Planar Submillimeter-Wave Mixer Technology with Integrated Antenna

    Science.gov (United States)

    Chattopadhyay, Gautam; Mehdi, Imran; Gill, John J.; Lee, Choonsup; lombart, Muria L.; Thomas, Betrand

    2010-01-01

    High-performance mixers at terahertz frequencies require good matching between the coupling circuits such as antennas and local oscillators and the diode embedding impedance. With the availability of amplifiers at submillimeter wavelengths and the need to have multi-pixel imagers and cameras, planar mixer architecture is required to have an integrated system. An integrated mixer with planar antenna provides a compact and optimized design at terahertz frequencies. Moreover, it leads to a planar architecture that enables efficient interconnect with submillimeter-wave amplifiers. In this architecture, a planar slot antenna is designed on a thin gallium arsenide (GaAs) membrane in such a way that the beam on either side of the membrane is symmetric and has good beam profile with high coupling efficiency. A coplanar waveguide (CPW) coupled Schottky diode mixer is designed and integrated with the antenna. In this architecture, the local oscillator (LO) is coupled through one side of the antenna and the RF from the other side, without requiring any beam sp litters or diplexers. The intermediate frequency (IF) comes out on a 50-ohm CPW line at the edge of the mixer chip, which can be wire-bonded to external circuits. This unique terahertz mixer has an integrated single planar antenna for coupling both the radio frequency (RF) input and LO injection without any diplexer or beamsplitters. The design utilizes novel planar slot antenna architecture on a 3- mthick GaAs membrane. This work is required to enable future multi-pixel terahertz receivers for astrophysics missions, and lightweight and compact receivers for planetary missions to the outer planets in our solar system. Also, this technology can be used in tera hertz radar imaging applications as well as for testing of quantum cascade lasers (QCLs).

  20. Use of profile and oblique incidence in scintigraphy in the osteo-articular pathology

    International Nuclear Information System (INIS)

    Saidi, L.; Langlet, D.; Fayolle, S.; Benada, A.; Prigent, A.

    1997-01-01

    The focal lesions observed in the osseous scintigraphy are sometimes difficult to interpret, notably, in sportsmen. Due to its high sensitivity this examination allows the diagnosis of small lesions even when these are not detectable by radiography. In exchange, its specificity is low. Sometimes, it is difficult to localize the osseous piece afflicted with high anatomic precision, making use of only the anterior and posterior incidences. We intended to test the profit of profile and oblique (3/4) incidences to specify the topography of afflicted zone and its anatomic relations with the neighbouring structures. The aim of this work is to illustrate by selected examples the use of this complement of imaging. The utilised camera is the DST-XL of SOPHA MEDICAL VISION (SMV) equipped with a UHR-BE collimator placed as closely as possible to the zone to be explored in a patient installed in dorsal decubitus. The acquisition is achieved by means of a 3-phase classical protocol. The activity injected is 8-13 MBq/Kg of 99m Tc-HMDP. The tardy images are effected at around 3 hours after the injection of tracer, with an 128/128 matrix and an acquisition time dependent of the region to be examined. The standard incidences are done on anterior and posterior faces and the complementary incidences in profile and oblique (3/4 anterior) positions. The profile and oblique incidences allowed to correct the diagnostic hypothesis deduced from anterior and posterior incidences. A table is given with the diagnoses obtained from standard incidences and the final diagnoses based on profile and oblique incidences for six types of clinic lesions. The conclusion is drawn that the selected examples are particularly demonstrative of the profit which the profile and oblique incidences brings about in making finer the topographic and sometimes etiological diagnosis. In numerous cases it allowed adopting a more specific therapeutic attitude towards the pathology identified in this way, notably in

  1. Hydrogenated arsenenes as planar magnet and Dirac material

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Shengli; Cai, Bo; Zeng, Haibo, E-mail: Huziyu@csrc.ac.cn, E-mail: zeng.haibo@njust.edu.cn [Institute of Optoelectronics and Nanomaterials, Herbert Gleiter Institute of Nanoscience, College of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); Hu, Yonghong [Institute of Optoelectronics and Nanomaterials, Herbert Gleiter Institute of Nanoscience, College of Materials Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); School of Nuclear Technology and Chemistry and Biology, Hubei University of Science and Technology, Xianning 437100 (China); Hu, Ziyu, E-mail: Huziyu@csrc.ac.cn, E-mail: zeng.haibo@njust.edu.cn [Beijing Computational Science Research Center, Beijing 100084 (China)

    2015-07-13

    Arsenene and antimonene are predicted to have 2.49 and 2.28 eV band gaps, which have aroused intense interest in the two-dimensional (2D) semiconductors for nanoelectronic and optoelectronic devices. Here, the hydrogenated arsenenes are reported to be planar magnet and 2D Dirac materials based on comprehensive first-principles calculations. The semi-hydrogenated (SH) arsenene is found to be a quasi-planar magnet, while the fully hydrogenated (FH) arsenene is a planar Dirac material. The buckling height of pristine arsenene is greatly decreased by the hydrogenation, resulting in a planar and relatively low-mass-density sheet. The electronic structures of arsenene are also evidently altered after hydrogenating from wide-band-gap semiconductor to metallic material for SH arsenene, and then to Dirac material for FH arsenene. The SH arsenene has an obvious magnetism, mainly contributed by the p orbital of the unsaturated As atom. Such magnetic and Dirac materials modified by hydrogenation of arsenene may have potential applications in future optoelectronic and spintronic devices.

  2. Hydrogenated arsenenes as planar magnet and Dirac material

    International Nuclear Information System (INIS)

    Zhang, Shengli; Cai, Bo; Zeng, Haibo; Hu, Yonghong; Hu, Ziyu

    2015-01-01

    Arsenene and antimonene are predicted to have 2.49 and 2.28 eV band gaps, which have aroused intense interest in the two-dimensional (2D) semiconductors for nanoelectronic and optoelectronic devices. Here, the hydrogenated arsenenes are reported to be planar magnet and 2D Dirac materials based on comprehensive first-principles calculations. The semi-hydrogenated (SH) arsenene is found to be a quasi-planar magnet, while the fully hydrogenated (FH) arsenene is a planar Dirac material. The buckling height of pristine arsenene is greatly decreased by the hydrogenation, resulting in a planar and relatively low-mass-density sheet. The electronic structures of arsenene are also evidently altered after hydrogenating from wide-band-gap semiconductor to metallic material for SH arsenene, and then to Dirac material for FH arsenene. The SH arsenene has an obvious magnetism, mainly contributed by the p orbital of the unsaturated As atom. Such magnetic and Dirac materials modified by hydrogenation of arsenene may have potential applications in future optoelectronic and spintronic devices

  3. Hydrogenated arsenenes as planar magnet and Dirac material

    Science.gov (United States)

    Zhang, Shengli; Hu, Yonghong; Hu, Ziyu; Cai, Bo; Zeng, Haibo

    2015-07-01

    Arsenene and antimonene are predicted to have 2.49 and 2.28 eV band gaps, which have aroused intense interest in the two-dimensional (2D) semiconductors for nanoelectronic and optoelectronic devices. Here, the hydrogenated arsenenes are reported to be planar magnet and 2D Dirac materials based on comprehensive first-principles calculations. The semi-hydrogenated (SH) arsenene is found to be a quasi-planar magnet, while the fully hydrogenated (FH) arsenene is a planar Dirac material. The buckling height of pristine arsenene is greatly decreased by the hydrogenation, resulting in a planar and relatively low-mass-density sheet. The electronic structures of arsenene are also evidently altered after hydrogenating from wide-band-gap semiconductor to metallic material for SH arsenene, and then to Dirac material for FH arsenene. The SH arsenene has an obvious magnetism, mainly contributed by the p orbital of the unsaturated As atom. Such magnetic and Dirac materials modified by hydrogenation of arsenene may have potential applications in future optoelectronic and spintronic devices.

  4. GPU-based simulation of the two-dimensional unstable structure of gaseous oblique detonations

    Energy Technology Data Exchange (ETDEWEB)

    Teng, H.H.; Kiyanda, C.B.; Ng, H.D. [Department of Mechanical and Industrial Engineering, Concordia University, Montréal, QC, H3G 1M8 (Canada); Morgan, G.H.; Nikiforakis, N. [Cavendish Laboratory, Department of Physics, University of Cambridge, Cambridge, CB3 0HE (United Kingdom)

    2015-03-10

    In this paper, the two-dimensional structure of unstable oblique detonations induced by the wedge from a supersonic combustible gas flow is simulated using the reactive Euler equations with a one-step Arrhenius chemistry model. A wide range of activation energy of the combustible mixture is considered. Computations are performed on the Graphical Processing Unit (GPU) to reduce the simulation runtimes. A large computational domain covered by a uniform mesh with high grid resolution is used to properly capture the development of instabilities and the formation of different transverse wave structures. After the initiation point, where the oblique shock transits into a detonation, an instability begins to manifest and in all cases, the left-running transverse waves first appear, followed by the subsequent emergence of right-running transverse waves forming the dual-head triple point structure. This study shows that for low activation energies, a long computational length must be carefully considered to reveal the unstable surface due to the slow growth rate of the instability. For high activation energies, the flow behind the unstable oblique detonation features the formation of unburnt gas pockets and strong vortex-pressure wave interaction resulting in a chaotic-like vortical structure.

  5. The number of colorings of planar graphs with no separating triangles

    DEFF Research Database (Denmark)

    Thomassen, Carsten

    2017-01-01

    A classical result of Birkhoff and Lewis implies that every planar graph with . n vertices has at least . 152n-1 distinct 5-vertex-colorings. Equality holds for planar triangulations with . n-4 separating triangles. We show that, if a planar graph has no separating triangle, then it has at least ...

  6. Planar waveguides and other confined geometries theory, technology, production, and novel applications

    CERN Document Server

    2015-01-01

    This book provides a comprehensive overview of the theoretical concepts and experimental applications of planar waveguides and other confined geometries, such as optical fibres. Covering a broad array of advanced topics, it begins with a sophisticated discussion of planar waveguide theory, and covers subjects including efficient production of planar waveguides, materials selection, nonlinear effects, and applications including species analytics down to single-molecule identification, and thermo-optical switching using planar waveguides. Written by specialists in the techniques and applications covered, this book will be a useful resource for advanced graduate students and researchers studying planar waveguides and optical fibers.

  7. Minimizing the Translation Error in the Application of an Oblique Single-Cut Rotation Osteotomy: Where to Cut?

    Science.gov (United States)

    Dobbe, Johannes G G; Strackee, Simon D; Streekstra, Geert J

    2018-04-01

    An oblique single cut rotation osteotomy enables correcting angular bone alignment in the coronal, sagittal, and transverse planes, with just a single oblique osteotomy, and by rotating one bone segment in the osteotomy plane. However, translational malalignment is likely to exist if the bone is curved or deformed and the location of the oblique osteotomy is not obvious. In this paper, we investigate how translational malalignment depends on the osteotomy location. We further propose and evaluate by simulation in 3-D, a method that minimizes translational malalignment by varying the osteotomy location and by sliding the distal bone segment with respect to the proximal bone segment within the oblique osteotomy plane. The method is finally compared to what three surgeons achieve by manually selecting the osteotomy location in 3-D virtual space without planning in-plane translations. The minimization method optimized for length better than the surgeons did, by 3.2 mm on average, range (0.1, 9.4) mm, in 82% of the cases. A better translation in the axial plane was achieved by 4.1 mm on average, range (0.3, 14.4) mm, in 77% of the cases. The proposed method generally performs better than subjectively choosing an osteotomy position along the bone axis. The proposed method is considered a valuable tool for future alignment planning of an oblique single-cut rotation osteotomy since it helps minimizing translational malalignment.

  8. Oblique rift opening revealed by reoccurring magma injection in central Iceland

    KAUST Repository

    Ruch, Joel; Wang, Teng; Xu, Wenbin; Hensch, Martin; Jonsson, Sigurjon

    2016-01-01

    -field deformation has rarely been captured, hindering progress in understanding rifting mechanisms and evolution. Here we show new evidence of oblique rift opening during a rifting event influenced by pre-existing fractures and two centuries of extension deficit

  9. Determination of crystallographic and macroscopic orientation of planar structures in TEM

    DEFF Research Database (Denmark)

    Huang, X.; Liu, Q.

    1998-01-01

    With the aid of a double-tilt holder in a transmission electron microscope (TEM), simple methods are described for determination of the crystallographic orientation of a planar structure and for calculation of the macroscopic orientation of the planar structure. The correlation between a planar...... structure and a crystallographic plane can be found by comparing the differences in their trace directions on the projection plane and inclination angles with respect to that plane. The angles between the traces of planar structures and the sample axis measured from the TEM micrographs, which have been...

  10. Radiation therapy planning of patients with breast cancer with the aid of parasternal lymphoscintigraphy

    International Nuclear Information System (INIS)

    Ohtake, Eiji

    1982-01-01

    This investigation was undertaken to establish the basis of the precise radiotherapy planning of the parasternal lymph nodes for patients with breast cancer. Twenty-four female patients with breast cancer were examined by parasternal lymphoscintigraphy. Their ages ranged from 26 to 76 years (average: 51.8 yrs). The parasternal lymphoscintigram was obtained 4 hours after bilateral subcostal injection of sup(99m)Tc-sulfur colloid or sup(99m)Tc-antimony sulfide colloid. The three-dimensional location of the lymph nodes was observed using both a conventional parallel hole collimator and a bilateral collimator. The following results were obtained. 1) The widest distance between the right and left chains of the parasternal lymph nodes was 5.6 +- 1.0 cm (n = 17, range: 4.1 - 7.7 cm). 2) The average lateral distance of the lymph nodes from the midsternal line was 2.3 +- 0.8 cm (n = 88, range: 0.7 - 5.2 cm). The lateral distance tended to be longer on the right side than on the left side. 3) The average depth of the lymph nodes from the surface of the skin was 2.3 +- 0.7 cm (n = 116, range: 0.9 - 4.3 cm). 4) The more the patients were obese, the more deeply seated the parasternal lymph nodes tended to be. 5) In the retrospective analysis of the conventional radiotherapy planning at the Tokyo Metropolitan Geriatric Hospital, it was found that about 59% of the parasternal lymph nodes were located in the radiation field and about 19% of the lymph nodes were seated within +-1 cm of the objective depth. In this paper, the author tries to emphasize that it might be important to examine the exact location and depth of the parasternal lymph nodes in each patient for the radiation therapy planning. (author)

  11. Electric-regulated enhanced in-plane uniaxial anisotropy in FeGa/PMN-PT composite using oblique pulsed laser deposition

    Science.gov (United States)

    Zhang, Yi; Huang, Chaojuan; Turghun, Mutellip; Duan, Zhihua; Wang, Feifei; Shi, Wangzhou

    2018-04-01

    The FeGa film with in-plane uniaxial magnetic anisotropy was fabricated onto different oriented single-crystal lead magnesium niobate-lead titanate using oblique pulsed laser deposition. An enhanced in-plane uniaxial magnetic anisotropy field of FeGa film can be adjusted from 18 Oe to 275 Oe by tuning the oblique angle and polarizing voltage. The competitive relationship of shape anisotropy and strain anisotropy has been discussed, which was induced by oblique angle and polarizing voltage, respectively. The (100)-oriented and (110)-oriented PMN-PT show completely different characters on voltage-dependent magnetic properties, which could be attributed to various anisotropy directions depended on different strain directions.

  12. Oblique convergence and the lobate mountain belts of western Pakistan

    Science.gov (United States)

    Haq, Saad S. B.; Davis, Dan M.

    1997-01-01

    The thin-skinned structures of the Pakistani convergent margin have formed as a consequence of the relative motion between India and Eurasia. Most of the resultant motion is being accommodated along or near the current edge of the Eurasian plate: the southwest-northeast striking Chaman fault zone. It has been observed at oblique margins that the total plate motion is resolved into a component parallel to the margin, accommodated through strike-slip faulting, and a component normal to the margin taken up as contraction. However, the orientations of structures along the Pakistani convergent margin in and around the Sulaiman lobe and Sulaiman Range cannot be explained simply by resolving the plate motion vector into components normal and parallel to the plate boundary. Our modeling suggests that the complex juxtaposition of strike-slip faults with thrust faults of various orientations can be explained by the presence of a block centered upon the Katawaz basin that translates along the southwest-northeast structural barrier of the Chaman fault zone, moving with respect to both Eurasia and India. As this relatively rigid block moves northeastward relative to Asia, it causes deformation of the sedimentary cover and is responsible for much of the structural complexity in the Pakistani foreland. Our simple model explains several first-order features of this oblique margin, such as the eastward-facing Sulaiman Range, the strike-slip Kingri fault (located between the Sulaiman lobe and Sulaiman Range), and the reentrant at Sibi. This leads us to conclude that very complex structural and geometric relationships at oblique convergent plate boundaries can result from the accommodation of strain with simple initial geometric constraints.

  13. Manufacturing of planar ceramic interconnects

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, B.L.; Coffey, G.W.; Meinhardt, K.D.; Armstrong, T.R. [Pacific Northwest National Lab., Richland, WA (United States)

    1996-12-31

    The fabrication of ceramic interconnects for solid oxide fuel cells (SOFC) and separator plates for electrochemical separation devices has been a perennial challenge facing developers. Electrochemical vapor deposition (EVD), plasma spraying, pressing, tape casting and tape calendering are processes that are typically utilized to fabricate separator plates or interconnects for the various SOFC designs and electrochemical separation devices. For sake of brevity and the selection of a planar fuel cell or gas separation device design, pressing will be the only fabrication technique discussed here. This paper reports on the effect of the characteristics of two doped lanthanum manganite powders used in the initial studies as a planar porous separator for a fuel cell cathode and as a dense interconnect for an oxygen generator.

  14. Guided wave imaging of oblique reflecting interfaces in pipes using common-source synthetic focusing

    Science.gov (United States)

    Sun, Zeqing; Sun, Anyu; Ju, Bing-Feng

    2018-04-01

    Cross-mode-family mode conversion and secondary reflection of guided waves in pipes complicate the processing of guided waves signals, and can cause false detection. In this paper, filters operating in the spectral domain of wavenumber, circumferential order and frequency are designed to suppress the signal components of unwanted mode-family and unwanted traveling direction. Common-source synthetic focusing is used to reconstruct defect images from the guided wave signals. Simulations of the reflections from linear oblique defects and a semicircle defect are separately implemented. Defect images, which are reconstructed from the simulation results under different excitation conditions, are comparatively studied in terms of axial resolution, reflection amplitude, detectable oblique angle and so on. Further, the proposed method is experimentally validated by detecting linear cracks with various oblique angles (10-40°). The proposed method relies on the guided wave signals that are captured during 2-D scanning of a cylindrical area on the pipe. The redundancy of the signals is analyzed to reduce the time-consumption of the scanning process and to enhance the practicability of the proposed method.

  15. The simple method to co-register planar image with photograph

    International Nuclear Information System (INIS)

    Jang, Sung June; Kim, Seok Ki; Kang, Keon Wook

    2005-01-01

    Generally scintigraphic image presents the highly specific functional information. Sometimes, there can be limited information of patients anatomical landmark required to identify the lesion in planar nuclear medicine image. In this study, we applied the simple fusion method of planar scintigraphy and plain photography and validated the techniques with our own software. We used three fiducial marks which were comprised with Tc-99m. We obtained planar image with single head gamma camera (ARGUS ADAC laboratory, USA) and photograph using a general digital camera (CANON JAPAN). The coordinates of three marks were obtained in photograph and planar scintigraphy image. Based on these points, we took affine transformation and then fused these two images. To evaluate the precision, we compared with different depth. To find out the depth of lesion, the images were acquired in different angles and we compared the real depth and the geometrically calculated depth. At the same depth with mark, the each discordance was less than 1 mm. When the photograph were taken at the distance with 1 m and 2 m, the point 30 cm off the center were discordant in 5 mm and 2 mm each. We used this method in the localization of the remnant thyroid tissue on I-131 whole body scan with photo image. The simple method to co-register planar image with photography was reliable and easy to use. By this method, we could localize the lesion on the planar scintigraphy more accurately with other planar images (i.e. photograph) and predict the depth of the lesion without tomographic image

  16. Role of ICG-{sup 99m}Tc-nanocolloid for sentinel lymph node detection in cervical cancer: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Paredes, Pilar; Vidal-Sicart, Sergi; Lomena, Francisco [Hospital Clinic, Nuclear Medicine Department, Barcelona (Spain); Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Campos, Francisco [Hospital Clinic, Nuclear Medicine Department, Radiopharmacy Unit, Barcelona (Spain); Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Tapias, Andres; Sanchez, Nuria [Hospital Clinic, Nuclear Medicine Department, Barcelona (Spain); Martinez, Sergio; Pahisa, Jaume; Torne, Aureli; Carmona, Francesc [Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Institut Clinic of Gynecology, Obstetrics and Neonatology, Hospital Clinic, Barcelona (Spain); Carballo, Lorena [Hospital Clinic, Nuclear Medicine Department, Radiopharmacy Unit, Barcelona (Spain); Ordi, Jaume [Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Hospital Clinic, Department of Pathology, Barcelona (Spain); Centre de Recerca en Salut Internacional de Barcelona (CRESIB), Barcelona (Spain)

    2017-10-15

    Sentinel lymph node biopsy (SLNB) can be used for nodal staging in early cervical cancer. For this purpose, the tracers most commonly used are radiotracers based on technetium. For the last decade, indocyanine green (ICG) has been used as a tracer for SLNB in other malignancies with excellent results and, more recently, a combination of ICG and a radiotracer has been shown to have the advantages of both tracers. The aim of this study was to evaluate the role of ICG-{sup 99m}Tc-nanocolloid in SLN detection in patients with cervical cancer. This prospective study included 16 patients with cervical cancer. The hybrid tracer was injected the day (19-21 h) before surgery for planar and SPECT/CT lymphoscintigraphy. Blue dye was administered periorificially in 14 patients. SLNs were removed according to their distribution on lymphoscintigraphy and when radioactive, fluorescent and/or stained with blue dye. Nodal specimens were pathologically analysed for metastases including by immunochemistry. Lymphoscintigraphy and SPECT/CT showed drainage in all patients. A total of 69 SLNs were removed, of which 66 were detected by their radioactivity signal and 67 by their fluorescence signal. Blue dye identified only 35 SLNs in 12 of the 14 patients (85.7%). All patients showed bilateral pelvic drainage. Micrometastases were diagnosed in two patients, and were the only lymphatic nodes involved. SLNB with ICG-{sup 99m}Tc-nanocolloid is feasible and safe in patients with early cervical cancer. This hybrid tracer provided bilateral SLN detection in all patients and a higher detection rate than blue dye, so it could become an alternative to the combined technique. (orig.)

  17. A Pilot Evaluation of On-Road Detection Performance by Drivers with Hemianopia Using Oblique Peripheral Prisms

    Directory of Open Access Journals (Sweden)

    Alex R. Bowers

    2012-01-01

    Full Text Available Aims. Homonymous hemianopia (HH, a severe visual consequence of stroke, causes difficulties in detecting obstacles on the nonseeing (blind side. We conducted a pilot study to evaluate the effects of oblique peripheral prisms, a novel development in optical treatments for HH, on detection of unexpected hazards when driving. Methods. Twelve people with complete HH (median 49 years, range 29–68 completed road tests with sham oblique prism glasses (SP and real oblique prism glasses (RP. A masked evaluator rated driving performance along the 25 km routes on busy streets in Ghent, Belgium. Results. The proportion of satisfactory responses to unexpected hazards on the blind side was higher in the RP than the SP drive (80% versus 30%; P=0.001, but similar for unexpected hazards on the seeing side. Conclusions. These pilot data suggest that oblique peripheral prisms may improve responses of people with HH to blindside hazards when driving and provide the basis for a future, larger-sample clinical trial. Testing responses to unexpected hazards in areas of heavy vehicle and pedestrian traffic appears promising as a real-world outcome measure for future evaluations of HH rehabilitation interventions aimed at improving detection when driving.

  18. A study of coFeB magnetic yoke based on planar electromagnet

    Science.gov (United States)

    Qin, L.; Li, Q.; Yuan, Yong J.

    2017-07-01

    This paper studies the fabrication of a novel planar electromagnet consisting of a planar copper coil and a magnetic yoke. CoFeB was used as the magnetic yoke material instead of the traditional permanent magnets. The planar electromagnet was fabricated and optimized to maximize the electromagnetic force, especially with varying CoFeB thickness. The micro-planar electromagnet was fabricated successfully by the traditional micro-electro-mechanical-system (MEMS) techniques and XRD, VSM were used to characterize the performance of the electromagnet. The planar electromagnet exhibits superior perpendicular magnetic anisotropy (PMA) and 0.006 emu of MS was achieved following 2 min deposition of CoFeB thin film. By integrating with other micro apparatuses, it is anticipated that the planar electromagnet will have potential applications in areas such as biosensors, biological medicine, drug delivery, chemical analysis and environmental monitoring.

  19. Treatment for incarcerated indirect hernia with “Cross-Internal Ring” inguinal oblique incision in children

    Directory of Open Access Journals (Sweden)

    Xue-Qiang Yan

    2017-01-01

    Full Text Available Background: This study aims to evaluate the utility of the “Cross-Internal Ring” inguinal oblique incision for the surgical treatment of incarcerated indirect hernia (IIH complicated with severe abdominal distension. Materials and Methods: Patients of IIH complicated with severe abdominal distension were reviewed retrospectively. All patients received operation through the “Cross-Internal Ring” inguinal oblique incision. Results: There were totally 13 patients were included, male to female ratio was 9-4. The time for patients to resume oral feeding varying from 2 to 5 days after operation, no complications include delayed intestinal perforation, intra-abdominal abscess, and incision infection happened. Average postoperative hospital stay was 5.2 days. All cases were followed up for 6–18 months. No recurrence or iatrogenic cryptorchidism happened. Conclusion: “Cross-Internal Ring” inguinal oblique incision is a simple, safe, and reliable surgical method to treat pediatric IIH complicated with severe abdominal distension.

  20. Evaluation of the internal oblique, external oblique, and transversus abdominalis muscles in patients with ankylosing spondylitis: an ultrasonographic study.

    Science.gov (United States)

    Üşen, Ahmet; Kuran, Banu; Yılmaz, Figen; Aksu, Neşe; Erçalık, Cem

    2017-11-01

    The objectives of the study are to compare abdominal muscle thickness in ankylosing spondylitis (AS) patients with healthy subjects and determine the factors affecting these muscle thickness. Thirty-five male patients with a previous diagnosis of AS according to the Modified New York criteria and a control group consisting of 35 healthy male individuals were included in this cross-sectional and case-control study. Thicknesses of the internal oblique (IO), external oblique (EO), and transversus abdominalis (TrA) muscles were measured with ultrasound (US). AS patients were classified according to the International Physical Activity Questionnaire (IPAQ). There were 35 AS patients with a mean age of 35.17 ± 8.05 years and 35 healthy subjects with a mean age 32.57 ± 7.05 years. No significant difference was observed between the groups in terms of abdominal muscle thicknesses (p > 0.005). When the AS patients were classified according to the IPAQ scores, thicknesses of the IO and TrA muscles were significantly lower in patients who had the low level of IPAQ scores (p < 0.05). In the light of our first and preliminary results, muscle thickness of the IO, EO, and TrA muscles were similar in AS patients to healthy subjects. However, AS patients who had lower level of physical activity have also reduced thickness of IO and TrA muscles.

  1. Design and measurements of the double layer planar motor

    NARCIS (Netherlands)

    Rovers, J.M.M.; Jansen, J.W.; Lomonova, E.

    2013-01-01

    Moving-magnet magnetically levitated planar motors are considered for use as a wafer stage in the semiconductor lithographic industry. This puts high requirements on the accuracy and the dissipated power and cooling performance of such motors. A novel planar motor topology is developed, which

  2. Conformal, planarizing and bridging AZ5214-E layers deposited by a 'draping' technique on non-planar III V substrates

    Science.gov (United States)

    Eliás, P.; Strichovanec, P.; Kostic, I.; Novák, J.

    2006-12-01

    A draping technique was tested for the deposition of positive-tone AZ5214-E photo-resist layers on non-planar (1 0 0)-oriented III-V substrates, which had a variety of three-dimensional (3D) topographies micromachined in them that consisted, e.g., of mesa ridges confined to side facets with variable tilt, inverted pyramidal holes and stubs confined to perpendicular side facets. All objects were sharp-edged. In each draping experiment, an AZ5214-E sheet was (1) formed floating on the water surface, (2) lowered onto a non-planar substrate and (3) draped over it during drying to form either self-sustained, or conformal, or planarizing layers over the non-planar substrates. The draping process is based on the depression of the glass transition temperature Tg of AZ5214-E material induced by penetrant water molecules that interact with AZ5214-E. During the process, the molecules are initially trapped under an AZ5214-E sheet and then transported out through the sheet via permeation. The water-AZ5214-E interaction modifies the stiffness κ of the sheet. The magnitude of the effect depends on temperature T and on partial water vapour pressure difference p(T, P, κ): the net effect is that Tg = f(C(T, P), p(T, P, κ)) is lowered as the concentration C of water increases with T and p, where P is the permeability of the sheet. The interaction depressed the Tg of the sheets as low as or lower than 53 °C for 6 µm thick sheets. At room temperature T Tg, the sheet becomes rubbery and mouldable by adhesion and capillary forces. As a result, it can either contour or planarize the topography depending on its geometry and thickness of the sheet.

  3. Fluorescence based fiber optic and planar waveguide biosensors. A review

    International Nuclear Information System (INIS)

    Benito-Peña, Elena; Valdés, Mayra Granda; Glahn-Martínez, Bettina; Moreno-Bondi, Maria C.

    2016-01-01

    The application of optical biosensors, specifically those that use optical fibers and planar waveguides, has escalated throughout the years in many fields, including environmental analysis, food safety and clinical diagnosis. Fluorescence is, without doubt, the most popular transducer signal used in these devices because of its higher selectivity and sensitivity, but most of all due to its wide versatility. This paper focuses on the working principles and configurations of fluorescence-based fiber optic and planar waveguide biosensors and will review biological recognition elements, sensing schemes, as well as some major and recent applications, published in the last ten years. The main goal is to provide the reader a general overview of a field that requires the joint collaboration of researchers of many different areas, including chemistry, physics, biology, engineering, and material science. - Highlights: • Principles, configurations and fluorescence techniques using fiber optic and planar waveguide biosensors are discussed. • The biorecognition elements and sensing schemes used in fiber optic and planar waveguide platforms are reviewed. • Some major and recent applications of fiber optic and planar waveguide biosensors are introduced.

  4. Fluorescence based fiber optic and planar waveguide biosensors. A review

    Energy Technology Data Exchange (ETDEWEB)

    Benito-Peña, Elena [Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, 28040 Madrid (Spain); Valdés, Mayra Granda [Department of Analytical Chemistry, Faculty of Chemistry, University of La Habana, 10400 La Habana (Cuba); Glahn-Martínez, Bettina [Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, 28040 Madrid (Spain); Moreno-Bondi, Maria C., E-mail: mcmbondi@quim.ucm.es [Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, 28040 Madrid (Spain)

    2016-11-02

    The application of optical biosensors, specifically those that use optical fibers and planar waveguides, has escalated throughout the years in many fields, including environmental analysis, food safety and clinical diagnosis. Fluorescence is, without doubt, the most popular transducer signal used in these devices because of its higher selectivity and sensitivity, but most of all due to its wide versatility. This paper focuses on the working principles and configurations of fluorescence-based fiber optic and planar waveguide biosensors and will review biological recognition elements, sensing schemes, as well as some major and recent applications, published in the last ten years. The main goal is to provide the reader a general overview of a field that requires the joint collaboration of researchers of many different areas, including chemistry, physics, biology, engineering, and material science. - Highlights: • Principles, configurations and fluorescence techniques using fiber optic and planar waveguide biosensors are discussed. • The biorecognition elements and sensing schemes used in fiber optic and planar waveguide platforms are reviewed. • Some major and recent applications of fiber optic and planar waveguide biosensors are introduced.

  5. Influence of vertically and obliquely propagating gravity waves on the polar summer mesosphere

    Science.gov (United States)

    Thurairajah, B.; Siskind, D. E.; Bailey, S. M.

    2017-12-01

    Polar Mesospheric Clouds (PMCs) are sensitive to changes in temperature of the cold polar summer mesosphere, which in turn are modulated by gravity waves (GWs). In this study we investigate the link between PMCs and GWs that propagate both vertically (i.e. wave propagation is directly above the source region) and obliquely (lateral or non-vertical propagation upward but away from the source region). Several observational studies have analyzed the link between PMCs and vertically propagating GWs and have reported both positive and negative correlations. Moreover, while modelling studies have noted the possibility of oblique propagation of GWs from the low-latitude stratosphere to the high-latitude mesosphere, observational studies of the influence of these waves on the polar summer mesosphere are sparse. We present a comprehensive analysis of the influence of vertically and obliquely propagating GWs on the northern hemisphere (NH) polar summer mesosphere using data from 8 PMC seasons. Temperature data from the SOFIE experiment on the AIM satellite and SABER instrument on the TIMED satellite are used to derive GW parameters. SOFIE PMC data in terms of Ice Water Content (IWC) are used to quantify the changes in the polar summer mesosphere. At high latitudes, preliminary analysis of vertically propagating waves indicate a weak but positive correlation between GWs at 50 km and GWs at the PMC altitude of 84 km. Overall there is a negative correlation between GWs at 50 km and IWC and a positive correlation between GWs at 84 km and IWC. These results and the presence of a slanted structure (slanted from the low-latitude stratosphere to the high-latitude mesosphere) in GW momentum flux suggest the possibility of a significant influence of obliquely propagating GWs on the polar summer mesosphere

  6. Enhanced sensitivity in a butterfly gyroscope with a hexagonal oblique beam

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Dingbang; Cao, Shijie; Hou, Zhanqiang, E-mail: houzhanqiang@nudt.edu.cn; Chen, Zhihua; Wang, Xinghua; Wu, Xuezhong [College of Mechatronics Engineering and Automation, National University of Defense Technology, Changsha, Hunan, 410073 (China)

    2015-04-15

    A new approach to improve the performance of a butterfly gyroscope is developed. The methodology provides a simple way to improve the gyroscope’s sensitivity and stability, by reducing the resonant frequency mismatch between the drive and sense modes. This method was verified by simulations and theoretical analysis. The size of the hexagonal section oblique beam is the major factor that influences the resonant frequency mismatch. A prototype, which has the appropriately sized oblique beam, was fabricated using precise, time-controlled multilayer pre-buried masks. The performance of this prototype was compared with a non-tuned gyroscope. The scale factor of the prototype reaches 30.13 mV/ °/s, which is 15 times larger than that obtained from the non-tuned gyroscope. The bias stability of the prototype is 0.8 °/h, which is better than the 5.2 °/h of the non-tuned devices.

  7. Modeling and optimization of planar microcoils

    International Nuclear Information System (INIS)

    Beyzavi, Ali; Nguyen, Nam-Trung

    2008-01-01

    Magnetic actuation has emerged as a useful tool for manipulating particles, droplets and biological samples in microfluidics. A planar coil is one of the suitable candidates for magnetic actuation and has the potential to be integrated in digital microfluidic devices. A simple model of microcoils is needed to optimize their use in actuation applications. This paper first develops an analytical model for calculating the magnetic field of a planar microcoil. The model was validated by experimental data from microcoils fabricated on printed circuit boards (PCB). The model was used for calculating the field strength and the force acting on a magnetic object. Finally, the effect of different coil parameters such as the magnitude of the electric current, the gap between the wires and the number of wire segments is discussed. Both analytical and experimental results show that a smaller gap size between wire segments, more wire segments and a higher electric current can increase both the magnitude and the gradient of the magnetic field, and consequently cause a higher actuating force. The planar coil analyzed in the paper is suitable for applications in magnetic droplet-based microfluidics

  8. THERMAL PHASES OF EARTH-LIKE PLANETS: ESTIMATING THERMAL INERTIA FROM ECCENTRICITY, OBLIQUITY, AND DIURNAL FORCING

    International Nuclear Information System (INIS)

    Cowan, Nicolas B.; Voigt, Aiko; Abbot, Dorian S.

    2012-01-01

    In order to understand the climate on terrestrial planets orbiting nearby Sun-like stars, one would like to know their thermal inertia. We use a global climate model to simulate the thermal phase variations of Earth analogs and test whether these data could distinguish between planets with different heat storage and heat transport characteristics. In particular, we consider a temperate climate with polar ice caps (like the modern Earth) and a snowball state where the oceans are globally covered in ice. We first quantitatively study the periodic radiative forcing from, and climatic response to, rotation, obliquity, and eccentricity. Orbital eccentricity and seasonal changes in albedo cause variations in the global-mean absorbed flux. The responses of the two climates to these global seasons indicate that the temperate planet has 3× the bulk heat capacity of the snowball planet due to the presence of liquid water oceans. The obliquity seasons in the temperate simulation are weaker than one would expect based on thermal inertia alone; this is due to cross-equatorial oceanic and atmospheric energy transport. Thermal inertia and cross-equatorial heat transport have qualitatively different effects on obliquity seasons, insofar as heat transport tends to reduce seasonal amplitude without inducing a phase lag. For an Earth-like planet, however, this effect is masked by the mixing of signals from low thermal inertia regions (sea ice and land) with that from high thermal inertia regions (oceans), which also produces a damped response with small phase lag. We then simulate thermal light curves as they would appear to a high-contrast imaging mission (TPF-I/Darwin). In order of importance to the present simulations, which use modern-Earth orbital parameters, the three drivers of thermal phase variations are (1) obliquity seasons, (2) diurnal cycle, and (3) global seasons. Obliquity seasons are the dominant source of phase variations for most viewing angles. A pole-on observer

  9. THERMAL PHASES OF EARTH-LIKE PLANETS: ESTIMATING THERMAL INERTIA FROM ECCENTRICITY, OBLIQUITY, AND DIURNAL FORCING

    Energy Technology Data Exchange (ETDEWEB)

    Cowan, Nicolas B. [Center for Interdisciplinary Exploration and Research in Astrophysics and Department of Physics and Astronomy, Northwestern University, 2131 Tech Drive, Evanston, IL 60208 (United States); Voigt, Aiko [Max Planck Institute for Meteorology, Bundesstr. 53, D-20146 Hamburg (Germany); Abbot, Dorian S., E-mail: n-cowan@nortwestern.edu [Department of Geophysical Sciences, University of Chicago, 5734 South Ellis Avenue, Chicago, IL 60637 (United States)

    2012-09-20

    In order to understand the climate on terrestrial planets orbiting nearby Sun-like stars, one would like to know their thermal inertia. We use a global climate model to simulate the thermal phase variations of Earth analogs and test whether these data could distinguish between planets with different heat storage and heat transport characteristics. In particular, we consider a temperate climate with polar ice caps (like the modern Earth) and a snowball state where the oceans are globally covered in ice. We first quantitatively study the periodic radiative forcing from, and climatic response to, rotation, obliquity, and eccentricity. Orbital eccentricity and seasonal changes in albedo cause variations in the global-mean absorbed flux. The responses of the two climates to these global seasons indicate that the temperate planet has 3 Multiplication-Sign the bulk heat capacity of the snowball planet due to the presence of liquid water oceans. The obliquity seasons in the temperate simulation are weaker than one would expect based on thermal inertia alone; this is due to cross-equatorial oceanic and atmospheric energy transport. Thermal inertia and cross-equatorial heat transport have qualitatively different effects on obliquity seasons, insofar as heat transport tends to reduce seasonal amplitude without inducing a phase lag. For an Earth-like planet, however, this effect is masked by the mixing of signals from low thermal inertia regions (sea ice and land) with that from high thermal inertia regions (oceans), which also produces a damped response with small phase lag. We then simulate thermal light curves as they would appear to a high-contrast imaging mission (TPF-I/Darwin). In order of importance to the present simulations, which use modern-Earth orbital parameters, the three drivers of thermal phase variations are (1) obliquity seasons, (2) diurnal cycle, and (3) global seasons. Obliquity seasons are the dominant source of phase variations for most viewing angles. A

  10. MRI diagnosis of ACL bundle tears: value of oblique axial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Alex W.H.; Griffith, James F.; Hung, Esther H.Y. [Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince of Wales Hospital, Shatin, NT, Hong Kong SAR (China); Law, Kan Yip; Yung, Patrick S.H. [Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince of Wales Hospital, Shatin, NT, Hong Kong SAR (China)

    2013-02-15

    To investigate the diagnostic accuracy of oblique axial intermediate weighting MR imaging in detecting partial thickness anterior cruciate ligament (ACL) bundle tears. The study protocol was approved by the institutional ethics committee. Sixty-one subjects (43 male, 18 female; mean age 27.4 years; range 9 to 57 years) with clinically suspected ACL tear or meniscal tear between September 2009 and January 2011 were studied with MRI and arthroscopy. Detection of partial tear for the ACL as a whole and for each ACL bundle by protocol A (standard orthogonal sequences) and protocol B (standard orthogonal sequences plus oblique axial intermediate weighted imaging) was compared in a blinded fashion. Performance characteristics for protocol A and protocol B were compared using sensitivity, specificity, accuracy and ROC curves. A two-tailed p value of <0.05 indicated statistical significance. Fifteen (24.6%) normal, 15 (24.6%) partial and 31 complete tears were diagnosed by arthroscopy. Sensitivity, specificity and accuracy of protocol A for the diagnosis of partial tear of the ACL was 33%, 87% and 74%, while for protocol B the values were 87%, 87% and 87% respectively. The area under the curve (AUC) for the diagnosis of partial ACL tear and individual bundle tear was higher for protocol B, although this difference did not reach statistical significance (p > 0.05). The addition of oblique axial imaging to standard MR imaging improves diagnostic accuracy for detecting partial tears of the ACL as well as individual bundle tears of the ACL. (orig.)

  11. Ambient mass spectrometry: From the planar to the non-planar surface analysis

    Czech Academy of Sciences Publication Activity Database

    Rejšek, Jan; Vrkoslav, Vladimír; Cvačka, Josef

    2017-01-01

    Roč. 15, č. 1 (2017), s. 31 ISSN 2336-7202. [Mezioborové setkání mladých biologů, biochemiků a chemiků /17./. 30.05.2017-01.06.2017, Milovy] Institutional support: RVO:61388963 Keywords : ambient mass spectrometry * thin layer chromatography * non-planar surface analysis Subject RIV: CB - Analytical Chemistry, Separation

  12. SPECT versus planar bone radionuclide imaging in the detection of spondylolysis

    International Nuclear Information System (INIS)

    Whitten, C.G.; El-Khoury, G.Y.; Chang, P.J.; Seabold, J.E.; Found, E.M.; Renfrew, D.L.

    1991-01-01

    This paper evaluates the relative performance and ease of interpretation of SPECT versus planar radionuclide bone imaging in the detection of spondylolysis. The authors studied all patients presenting with back pain suggestive of spondylolysis from November 1989 to January 1991 who underwent bone scanning; patients underwent both planar and SPECT imaging. The planar and SPECT images were randomly mixed and independently interpreted by four observers for presence or absence of spondylolysis and ease of interpretation for each scan. Receiver operating characteristic (ROC) and analysis of variance (ANOVA) were used. Of 72 patients, 19 had confirmed spondylolysis, and 53 did not. While ROC analysis showed that SPECT performed slightly better than planar imaging for all four observers, the difference was not statistically significant. ANOVA results suggest that planar imaging was significantly easier to use than SPECT and that ease of use was strongly correlated with the observer's confidence in the diagnosis

  13. Thermal self-focusing at oblique incidence

    International Nuclear Information System (INIS)

    Craxton, R.S.; McCrory, R.L.

    1984-03-01

    Thermal self-focusing at oblique incidence has been investigated in two-dimensional line-focus geometry using the Eulerian hydrodynamics simulation code SAGE. The laser beam interacts with a long-scale-length preformed plasma with an expontial density profiele. Questions to be addressed include: (1) What happens when a self-focusing channel reaches the turning point of the incident rays, and (2) Does the unabsorbed light return in the specular direction or back along the channel. A comparison is also made between thermal self-focusing at normal incidence in cylindrical and line-focus geometries: in cylindrical geometry the self-focusing mechanism is enhanced by the relative ease with which plasma may be expelled from a small cylindrical channel

  14. Spatial evolution of Zagros collision zone in Kurdistan - NW Iran, constraints for Arabia-Eurasia oblique convergence

    Science.gov (United States)

    Sadeghi, S.; Yassaghi, A.

    2015-09-01

    Stratigraphy, detailed structural mapping and crustal scale cross section of the NW Zagros collision zone evolved during convergence of the Arabian and Eurasian plates were conducted to constrain the spatial evolution of the belt oblique convergence since Late Cretaceous. Zagros orogeny in NW Iran consists of the Sanandaj-Sirjan, Gaveh Rud and ophiolite zones as internal, and Bisotoun, Radiolarite and High Zagros zones as external parts. The Main Zagros Thrust is known as major structures of the Zagros suture zone. Two stages of deformation are recognized in the external parts of Zagros. In the early stage, presence of dextrally deformed domains beside the reversely deformed domains in the Radiolarite zone as well as dextral-reverse faults in both Bisotoun and Radiolarite zones demonstrates partitioning of the dextral transpression. In the late stage, southeastward propagation of the Zagros orogeny towards its foreland resulted in synchronous development of orogen-parallel strike-slip and pure thrust faults. It is proposed that the first stage related to the late Cretaceous oblique obduction, and the second stage is resulted from Cenozoic collision. Cenozoic orogen-parallel strike-slip component of Zagros oblique faulting is not confined to the Zagros suture zone (Main Recent) but also occurred in the more external part (Marekhil-Ravansar fault system). Thus, it is proposed that oblique convergence of Arabia-Eurasia plates occurred in Zagros collision zone since the Late Cretaceous.

  15. Theory and analysis of a large field polarization imaging system with obliquely incident light.

    Science.gov (United States)

    Lu, Xiaotian; Jin, Weiqi; Li, Li; Wang, Xia; Qiu, Su; Liu, Jing

    2018-02-05

    Polarization imaging technology provides information about not only the irradiance of a target but also the polarization degree and angle of polarization, which indicates extensive application potential. However, polarization imaging theory is based on paraxial optics. When a beam of obliquely incident light passes an analyser, the direction of light propagation is not perpendicular to the surface of the analyser and the applicability of the traditional paraxial optical polarization imaging theory is challenged. This paper investigates a theoretical model of a polarization imaging system with obliquely incident light and establishes a polarization imaging transmission model with a large field of obliquely incident light. In an imaging experiment with an integrating sphere light source and rotatable polarizer, the polarization imaging transmission model is verified and analysed for two cases of natural light and linearly polarized light incidence. Although the results indicate that the theoretical model is consistent with the experimental results, the theoretical model distinctly differs from the traditional paraxial approximation model. The results prove the accuracy and necessity of the theoretical model and the theoretical guiding significance for theoretical and systematic research of large field polarization imaging.

  16. The value of filtered planar images in pediatric DMSA scans

    International Nuclear Information System (INIS)

    Mohammed, A.M.; Naddaf, S.Y.; Elgazzar, A.H.; Al-Abdul Salam, A.A.; Omar, A.A.

    2006-01-01

    The study was designed to demonstrate the value of filtered planar images in paediatric DMSA scanning. One hundred and seventy three patients ranged in age from 15 days to 12 years (mean: 4.3 years) with urinary tract infection (UTI) and clinical and/or laboratory suspicion of acute pyelonephritis (APN) were retrospectively studied. Planar images were filtered using Butterworth filter. The scan findings were reported as positive, negative or equivocal for cortical defects. Each scan was read in a double-blind fashion by two nuclear medicine physicians to evaluate inter-observer variations. Each kidney was divided into three zones, upper, middle and lower, and each zone was graded as positive, negative or equivocal for the presence of renal defects. Renal cortical defects were found in 66 patients (91 kidneys and 186 zones) with filtered images, 58 patients (81 kidneys and 175 zones) with planar images, and 69 patients (87 kidneys and 180 zones) with SPECT images. McNemar's test revealed statistically significant difference between filtered and planar images (p=0.038 for patients, 0.021 for kidneys and 0.034 for number of zones). Inter-observer agreement was 0.877 for filtered images, 0.915 for planar images and 0.915 for SPECT images. It was concluded that filtered planar images of renal cortex are comparable to SPECT images and can be used effectively in place of SPECT, when required, to shorten imaging time and eliminate motion artifacts, especially in the paediatric population. (author)

  17. Flow and sediment transport across oblique channels

    DEFF Research Database (Denmark)

    Hjelmager Jensen, Jacob; Madsen, Erik Østergaard; Fredsøe, Jørgen

    1998-01-01

    A 3D numerical investigation of flow across channels aligned obliquely to the main flow direction has been conducted. The applied numerical model solves the Reynolds-averaged Navier-Stokes equations using the k-ε model for turbulence closure on a curvilinear grid. Three momentum equations...... are solved, but the computational domain is 2D due to a uniformity along the channel alignment. Two important flow features arise when the flow crosses the channel: (i) the flow will be refracted in the direction of the channel alignment. This may be described by a depth-averaged model. (ii) due to shear...

  18. Modeling and analysis of a novel planar eddy current damper

    Science.gov (United States)

    Zhang, He; Kou, Baoquan; Jin, Yinxi; Zhang, Lu; Zhang, Hailin; Li, Liyi

    2014-05-01

    In this paper, a novel 2-DOF permanent magnet planar eddy current damper is proposed, of which the stator is made of a copper plate and the mover is composed of two orthogonal 1-D permanent magnet arrays with a double sided structure. The main objective of the planar eddy current damper is to provide two orthogonal damping forces for dynamic systems like the 2-DOF high precision positioning system. Firstly, the basic structure and the operating principle of the planar damper are introduced. Secondly, the analytical model of the planar damper is established where the magnetic flux density distribution of the permanent magnet arrays is obtained by using the equivalent magnetic charge method and the image method. Then, the analytical expressions of the damping force and damping coefficient are derived. Lastly, to verify the analytical model, the finite element method (FEM) is adopted for calculating the flux density and a planar damper prototype is manufactured and thoroughly tested. The results from FEM and experiments are in good agreement with the ones from the analytical expressions indicating that the analytical model is reasonable and correct.

  19. Oblique Propagation of Fast Surface Waves in a Low-Beta Hall-Magnetohydrodynamics Plasma Slab

    International Nuclear Information System (INIS)

    Zhelyazkov, I.; Mann, G.

    1999-01-01

    The oblique propagation of fast sausage and kink magnetohydrodynamics (MHD) surface waves in an ideal magnetized plasma slab in the low-beta plasma limit is studied considering the Hall term in the generalized Ohm's law. It is found that the combined action of the Hall effect and oblique wave propagation makes possible the existence of multivalued solutions to the wave dispersion relations - some of them corresponding to positive values of the transfer wave number, k y , undergo a 'propagation stop' at specific (numerically found) full wave numbers. It is also shown that with growing wave number the waves change their nature - from bulk modes to pseudosurface or pure surface waves. (author)

  20. Dynamical analysis of surface-insulated planar wire array Z-pinches

    Science.gov (United States)

    Li, Yang; Sheng, Liang; Hei, Dongwei; Li, Xingwen; Zhang, Jinhai; Li, Mo; Qiu, Aici

    2018-05-01

    The ablation and implosion dynamics of planar wire array Z-pinches with and without surface insulation are compared and discussed in this paper. This paper first presents a phenomenological model named the ablation and cascade snowplow implosion (ACSI) model, which accounts for the ablation and implosion phases of a planar wire array Z-pinch in a single simulation. The comparison between experimental data and simulation results shows that the ACSI model could give a fairly good description about the dynamical characteristics of planar wire array Z-pinches. Surface insulation introduces notable differences in the ablation phase of planar wire array Z-pinches. The ablation phase is divided into two stages: insulation layer ablation and tungsten wire ablation. The two-stage ablation process of insulated wires is simulated in the ACSI model by updating the formulas describing the ablation process.

  1. Oblique non-neutral solitary Alfven modes in weakly nonlinear pair plasmas

    International Nuclear Information System (INIS)

    Verheest, Frank; Lakhina, G S

    2005-01-01

    The equal charge-to-mass ratio for both species in pair plasmas induces a decoupling of the linear eigenmodes between waves that are charge neutral or non-neutral, also at oblique propagation with respect to a static magnetic field. While the charge-neutral linear modes have been studied in greater detail, including their weakly and strongly nonlinear counterparts, the non-neutral mode has received less attention. Here the nonlinear evolution of a solitary non-neutral mode at oblique propagation is investigated in an electron-positron plasma. Employing the framework of reductive perturbation analysis, a modified Korteweg-de Vries equation (with cubic nonlinearity) for the lowest-order wave magnetic field is obtained. In the linear approximation, the non-neutral mode has its magnetic component orthogonal to the plane spanned by the directions of wave propagation and of the static magnetic field. The linear polarization is not maintained at higher orders. The results may be relevant to the microstructure in pulsar radiation or to the subpulses

  2. Coronal oblique imaging of the knee: Can it increase radiologists' confidence in diagnosing posterior root meniscal tears?

    International Nuclear Information System (INIS)

    Casagranda, B.U.; Leeman, J.; Costello, J.M.; Rafiee, B.; Harner, C.D.

    2013-01-01

    Aim: To investigate the utility of the coronal oblique sequence in the interrogation of posterior root meniscal lesions. Materials and methods: Following international review board approval, 62 consecutive knee arthroscopy cases were referred to the musculoskeletal (MSK) radiologists from the same orthopaedic surgeon for imaging/surgical correlation of the posterior meniscal roots. Of 62 cases, 45 lateral and 46 medial menisci met the inclusion criteria. Imaging evaluation was performed with standard magnetic resonance imaging (MRI) sequences, including a coronal oblique proton density sequence. Two blinded fellowship-trained MSK radiologists independently evaluated the menisci on standard sequences indicating whether a tear was identified and then specifying a confidence score using a scale of 1–3 on each study interpreted. Immediately thereafter, the coronal oblique sequence was evaluated using the same method. Statistics were performed on meniscal lesions involving the posterior horn/root junction or isolated root tears comparing confidence scores. Results: Reader A identified nine posterior horn/root junction tears and 14 isolated root tears. Following the addition of the coronal oblique sequence, confidence scores increased in three of 14 (21.4%) isolated root tears. All three final reads were concordant with arthroscopy. Reader B identified 10 posterior horn/root junction tears and 19 isolated root tears. The confidence score increased in six cases: five of 19 (26.3%) isolated root tears and one of 10 (10%) posterior horn/root junction tears. All six final reads were concordant with arthroscopy. Kappa coefficients indicated near perfect agreement. Conclusion: The coronal oblique sequence increased reader confidence in nearly 24% of the posterior root cases identified in this series

  3. Sonography of the anterior oblique ligament of the trapeziometacarpal joint: a study of cadavers and asymptomatic volunteers.

    Science.gov (United States)

    Chiavaras, Mary M; Harish, Srinivasan; Oomen, Glen; Popowich, Terry; Wainman, Bruce; Bain, James R

    2010-12-01

    The purpose of this study was to evaluate the ability of ultrasound to identify and characterize the anterior oblique ligament of the thumb in cadavers and asymptomatic volunteers. The anterior oblique ligaments of four cadaveric hands were imaged with a high-resolution transducer. The ligaments were then injected with 0.1% methylene blue using ultrasound guidance. To confirm identification of the ligament, the base of the thumb was immediately dissected, revealing the exact location of the dye. The bilateral ligaments in 40 asymptomatic adult volunteers were imaged. Surgical dissection confirmed injection of methylene blue into all cadaveric ligaments. The proximal attachment of the anterior oblique ligament was well defined in all the hands, and the distal attachment was well defined in 94% of the hands. The mean thickness of the anterior oblique ligament at the metacarpal attachment (0.7 mm), midportion (0.98 mm), and trapezial attachment (0.65 mm) did not differ significantly with respect to sex, right and left side, or hand dominance and was weakly correlated with weight, height, body mass index, and age. The length of the ligament was statistically significantly different between the dominant (10.6 mm) and nondominant (9.6 mm) hands. The volar metacarpal translation with palmar abduction stress did not differ significantly between the dominant (0.7 mm) and nondominant (0.8 mm) hands. There was no association between the degree of translation and the biologic characteristics (weight, height, body mass index, and age). High-resolution ultrasound can be used to identify and measure the thickness of the anterior oblique ligament. Dynamic ultrasound imaging can depict volar translation of the metacarpal, which may facilitate diagnosis of ligamentous injury.

  4. Anisotropic Magnus Force in Type-II Superconductors with Planar Defects

    Science.gov (United States)

    Monroy, Ricardo Vega; Gomez, Eliceo Cortés

    2015-02-01

    The effect of planar defects on the Magnus force in type-II superconductors is studied. It is shown that the deformation of the vortex due to the presence of a planar defect leads to a local decrease in the mean free path of electrons in the vortex. This effect reduces the effective Magnus coefficient in normal direction to the planar defect, leading to an anisotropic regime of the Hall effect. The presented developments here can qualitatively explain experimental observations of the anisotropic Hall effect in high- T c superconductors in the mixed state.

  5. What is the real angle of deviation of metacarpal neck fractures on oblique views? A radiographic study

    Directory of Open Access Journals (Sweden)

    Arthur de Góes Ribeiro

    2016-04-01

    Full Text Available OBJECTIVE: The aim of this study was to establish an indirect, easy-to-use, predictable and safe means of obtaining the true degree of displacement of fractures of the neck of the fifth metacarpal bone, through oblique radiographic views. METHODS: An anatomical specimen from the fifth human metacarpal was dissected and subjected to ostectomy in the neck region. A 1-mm Kirschner wire was fixed to the base of the fifth metacarpal bone, perpendicular to the longitudinal axis of the bone and parallel to the ground. Another six Kirschner wires of the same diameter were bent over and attached to the ostectomized bone to simulate fracture displacement. Axial rotation of the metacarpus was used to create oblique radiographic views. Radiographic images were generated with different angles and at several degrees of rotation of the bone. RESULTS: We deduced a mathematical formula that showed the true displacement of fractures of the neck of the fifth metacarpal bone by means of oblique radiographs. CONCLUSIONS: Oblique radiographs at 30° of supination provided the best view of the bone and least variation from the real value of the displacement of fractures of the fifth metacarpal bone. The mathematical formula deduced was concordant with the experimental model used.

  6. HP Ge planar detectors

    International Nuclear Information System (INIS)

    Gornov, M.G.; Gurov, Yu.B.; Soldatov, A.M.; Osipenko, B.P.; Yurkowski, J.; Podkopaev, O.I.

    1989-01-01

    Parameters of planar detectors manufactured of HP Ge are presented. The possibilities to use multilayer spectrometers on the base of such semiconductor detectors for nuclear physics experiments are discussed. It is shown that the obtained detectors including high square ones have spectrometrical characteristics close to limiting possible values. 9 refs.; 3 figs.; 1 tab

  7. Slices: A shape-proxy based on planar sections

    KAUST Repository

    McCrae, James

    2011-12-01

    Minimalist object representations or shape-proxies that spark and inspire human perception of shape remain an incompletely understood, yet powerful aspect of visual communication. We explore the use of planar sections, i.e., the contours of intersection of planes with a 3D object, for creating shape abstractions, motivated by their popularity in art and engineering. We first perform a user study to show that humans do define consistent and similar planar section proxies for common objects. Interestingly, we observe a strong correlation between user-defined planes and geometric features of objects. Further we show that the problem of finding the minimum set of planes that capture a set of 3D geometric shape features is both NP-hard and not always the proxy a user would pick. Guided by the principles inferred from our user study, we present an algorithm that progressively selects planes to maximize feature coverage, which in turn influence the selection of subsequent planes. The algorithmic framework easily incorporates various shape features, while their relative importance values are computed and validated from the user study data. We use our algorithm to compute planar slices for various objects, validate their utility towards object abstraction using a second user study, and conclude showing the potential applications of the extracted planar slice shape proxies.

  8. Quasi-planar elemental clusters in pair interactions approximation

    Directory of Open Access Journals (Sweden)

    Chkhartishvili Levan

    2016-01-01

    Full Text Available The pair-interactions approximation, when applied to describe elemental clusters, only takes into account bonding between neighboring atoms. According to this approach, isomers of wrapped forms of 2D clusters – nanotubular and fullerene-like structures – and truly 3D clusters, are generally expected to be more stable than their quasi-planar counterparts. This is because quasi-planar clusters contain more peripheral atoms with dangling bonds and, correspondingly, fewer atoms with saturated bonds. However, the differences in coordination numbers between central and peripheral atoms lead to the polarization of bonds. The related corrections to the molar binding energy can make small, quasi-planar clusters more stable than their 2D wrapped allotropes and 3D isomers. The present work provides a general theoretical frame for studying the relative stability of small elemental clusters within the pair interactions approximation.

  9. Review of the dynamic behaviour of sports balls during normal and oblique impacts

    Science.gov (United States)

    Haron, Muhammad Adli; Jailani, Azrol; Abdullah, Nik Ahmad Faris Nik; Ismail, Rafis Suizwan; Rahim, Shayfull Zamree Abd; Ghazali, Mohd Fathullah

    2017-09-01

    In this paper are review of impact experiment to study the dynamic behaviour of sports ball during oblique and normal impacts. In previous studies, the investigation was done on the dynamic behaviour of a sports ball during oblique and normal impacts from experimental, numerical, and theoretical viewpoints. The experimental results are analysed and compared with the theories, in order to understand the dynamics behaviours based on the phenomenological occurrence. Throughout the experimental studies previously, there are results of dynamics behaviours examined by many researchers such as the coefficient of restitution, tangential coefficient, local deformation, dynamic impact force, contact time, angle of impact (inbound and rebound), spin rate of the ball, ball stiffness and damping coefficient which dependable of the initial or impact velocity.

  10. Reflection of Lamb waves obliquely incident on the free edge of a plate.

    Science.gov (United States)

    Santhanam, Sridhar; Demirli, Ramazan

    2013-01-01

    The reflection of obliquely incident symmetric and anti-symmetric Lamb wave modes at the edge of a plate is studied. Both in-plane and Shear-Horizontal (SH) reflected wave modes are spawned by an obliquely incident in-plane Lamb wave mode. Energy reflection coefficients are calculated for the reflected wave modes as a function of frequency and angle of incidence. This is done by using the method of orthogonal mode decomposition and by enforcing traction free conditions at the plate edge using the method of collocation. A PZT sensor network, affixed to an Aluminum plate, is used to experimentally verify the predictions of the analysis. Experimental results provide support for the analytically determined results. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Application of holographic elements in displays and planar illuminators

    Science.gov (United States)

    Putilin, Andrew; Gustomiasov, Igor

    2007-05-01

    Holographic Optical Elements (HOE's) on planar waveguides can be used to design the planar optics for backlit units, color selectors or filters, lenses for virtual reality displays. The several schemes for HOE recording are proposed to obtain planar stereo backlit unit and private eye displays light source. It is shown in the paper that the specific light transformation grating permits to construct efficient backlit units for display holograms and LCD. Several schemes of reflection/transmission backlit units and scattering films based on holographic optical elements are also proposed. The performance of the waveguide HOE can be optimized using the parameters of recording scheme and etching parameters. The schemes of HOE application are discussed and some experimental results are shown.

  12. Group theoretical construction of planar noncommutative phase spaces

    Energy Technology Data Exchange (ETDEWEB)

    Ngendakumana, Ancille, E-mail: nancille@yahoo.fr; Todjihoundé, Leonard, E-mail: leonardt@imsp.uac.org [Institut de Mathématiques et des Sciences Physiques (IMSP), Porto-Novo (Benin); Nzotungicimpaye, Joachim, E-mail: kimpaye@kie.ac.rw [Kigali Institute of Education (KIE), Kigali (Rwanda)

    2014-01-15

    Noncommutative phase spaces are generated and classified in the framework of centrally extended anisotropic planar kinematical Lie groups as well as in the framework of noncentrally abelian extended planar absolute time Lie groups. Through these constructions the coordinates of the phase spaces do not commute due to the presence of naturally introduced fields giving rise to minimal couplings. By symplectic realizations methods, physical interpretations of generators coming from the obtained structures are given.

  13. Group theoretical construction of planar noncommutative phase spaces

    International Nuclear Information System (INIS)

    Ngendakumana, Ancille; Todjihoundé, Leonard; Nzotungicimpaye, Joachim

    2014-01-01

    Noncommutative phase spaces are generated and classified in the framework of centrally extended anisotropic planar kinematical Lie groups as well as in the framework of noncentrally abelian extended planar absolute time Lie groups. Through these constructions the coordinates of the phase spaces do not commute due to the presence of naturally introduced fields giving rise to minimal couplings. By symplectic realizations methods, physical interpretations of generators coming from the obtained structures are given

  14. Oblique Chest Views as a Routine Part of Skeletal Surveys Performed for Possible Physical Abuse--Is This Practice Worthwhile?

    Science.gov (United States)

    Hansen, Karen Kirhofer; Prince, Jeffrey S.; Nixon, G. William

    2008-01-01

    Objective: To evaluate the utility of oblique chest views in the diagnosis of rib fractures when used as a routine part of the skeletal survey performed for possible physical abuse. Methods: Oblique chest views have been part of the routine skeletal survey protocol at Primary Children's Medical Center since October 2002. Dictated radiology reports…

  15. Miniaturized Air-Driven Planar Magnetic Generators

    Directory of Open Access Journals (Sweden)

    Jingjing Zhao

    2015-10-01

    Full Text Available This paper presents the design, analysis, fabrication and testing of two miniaturized air-driven planar magnetic generators. In order to reduce the magnetic resistance torque, Generator 1 establishes a static magnetic field by consisting a multilayer planar coil as the stator and two multi-pole permanent-magnet (PM rotors on both sides of the coil. To further decrease the starting torque and save more space, Generator 2 adopts the multilayer planar coil as the rotor and the multi-pole PMs as the stator, eliminating the casing without compromising the magnetic structure or output performance. The prototypes were tested gathering energy from wind which can work at a low wind speed of 1~2 m/s. Prototype of Generator 1 is with a volume of 2.61 cm3 and its normalized voltage reaches 485 mV/krpm. Prototype of Generator 2 has a volume of 0.92 cm3 and a normalized voltage as high as 538 mV/krpm. Additionally, output voltage can be estimated at better than 96% accuracy by the theoretical model developed in this paper. The two micro generators are capable of producing substantial electricity with little volume to serve as compact power conversion devices.

  16. Feasibility study of axillary reverse mapping lymphoscintigraphy in carcinoma breast: A concept toward preventing lymphedema

    International Nuclear Information System (INIS)

    Gandhi, Sunny J.; Satish, C.; Sundaram, Palaniswamy Shanmuga; Subramanyam, Padma; Vijaykumar, D. K.

    2016-01-01

    In the surgery of breast cancer, axillary reverse mapping (ARM) is the identification and preservation of arm draining lymph node (ARM node) during an axillary dissection. The assumption is that the ARM node is different from node draining breast and is unlikely to be involved even in the patients with axillary nodal metastases. If we can identify and preserve ARM node using lymphoscintigraphy; morbidity of lymphedema, as seen with axillary dissection, may be avoided. Pathologically proven 50 breast cancer patients undergoing initial surgery (cTx-4, cN0-2, and Mx-0) were included in this study. Less than 37 MBq, 0.5 ml in equally divided doses of filtered 99mTc sulfur colloid was injected intradermally into the second and third web spaces. ARM nodes in the axilla were identified with the help of Gamma Probe intraoperatively; however, their location was noted with the reference to specific anatomical landmarks and sent for histopathological examination after excision. The ARM node was successfully identified in 47/50 cases (sensitivity - 94%). In 40 out of 47 cases (85%), the location of the ARM node was found to lateral to the subscapular pedicle, above the second intercostobrachial nerve and just below the axillary vein. Of the 47 patients in whom ARM node/s were identified, metastasis was noted in 5 of them (10%). Four out of these 5 patients had the pN3 disease. ARM node exists, and it is feasible to identify ARM node using radio isotope technique with an excellent sensitivity. ARM node seems to have a fairly constant location in more than 80% cases. It is involved with metastasis (10% cases) only when there are multiple lymph nodal metastases in the axilla

  17. Ultrasound evaluation of muscle thickness changes in the external oblique, internal oblique, and transversus abdominis muscles considering the influence of posture and muscle contraction.

    Science.gov (United States)

    Sugaya, Tomoaki; Abe, Yota; Sakamoto, Masaaki

    2014-09-01

    [Purpose] The aim of this study was to investigate muscle thickness changes in the external oblique (EO), internal oblique (IO), and transversus abdominis (TrA) muscles between the neutral position and trunk rotation, under a state of rest without voluntary contractions, and isometric contractions to both sides with resistance of 50% of the maximum trunk rotation strength. [Subjects] The subjects of this study were 21 healthy young men. [Methods] Muscle thickness changes in the EO, IO, and TrA in each position and state were evaluated by ultrasound. The range of motion at maximum trunk rotation and the maximum strength of trunk rotation were measured using a hand-held dynamometer. [Results] In the neutral position and at 50% trunk rotation to the right side, the thicknesses of the IO and TrA significantly increased with resistance. In both states, the thicknesses of the IO and TrA significantly increased at 50% trunk rotation to the right side. [Conclusion] The muscular contractions of the IO and TrA were stronger during ipsilateral rotation than in the neutral position and with resistance than at rest. Moreover, the muscular contraction was strongest in the resistive state during ipsilateral rotation.

  18. Enhanced sensitivity of surface plasmon resonance phase-interrogation biosensor by using oblique deposited silver nanorods.

    Science.gov (United States)

    Chung, Hung-Yi; Chen, Chih-Chia; Wu, Pin Chieh; Tseng, Ming Lun; Lin, Wen-Chi; Chen, Chih-Wei; Chiang, Hai-Pang

    2014-01-01

    Sensitivity of surface plasmon resonance phase-interrogation biosensor is demonstrated to be enhanced by oblique deposited silver nanorods. Silver nanorods are thermally deposited on silver nanothin film by oblique angle deposition (OAD). The length of the nanorods can be tuned by controlling the deposition parameters of thermal deposition. By measuring the phase difference between the p and s waves of surface plasmon resonance heterodyne interferometer with different wavelength of incident light, we have demonstrated that maximum sensitivity of glucose detection down to 7.1 × 10(-8) refractive index units could be achieved with optimal deposition parameters of silver nanorods.

  19. Topics in the Analysis of Shear-Wave Propagation in Oblique-Plate Impact Tests

    National Research Council Canada - National Science Library

    Scheidler, Mike

    2007-01-01

    This report addresses several topics in the theoretical analysis of shock waves, acceleration waves, and centered simple waves, with emphasis on the propagation of shear waves generated in oblique-plate impact tests...

  20. Routed planar networks

    Directory of Open Access Journals (Sweden)

    David J. Aldous

    2016-04-01

    Full Text Available Modeling a road network as a planar graph seems very natural. However, in studying continuum limits of such networks it is useful to take {\\em routes} rather than {\\em edges} as primitives. This article is intended to introduce the relevant (discrete setting notion of {\\em routed network} to graph theorists. We give a naive classification of all 71 topologically different such networks on 4 leaves, and pose a variety of challenging research questions.

  1. Characterization of Oblique Dual Frame Pairs

    Directory of Open Access Journals (Sweden)

    Christensen Ole

    2006-01-01

    Full Text Available Given a frame for a subspace of a Hilbert space , we consider all possible families of oblique dual frame vectors on an appropriately chosen subspace . In place of the standard description, which involves computing the pseudoinverse of the frame operator, we develop an alternative characterization which in some cases can be computationally more efficient. We first treat the case of a general frame on an arbitrary Hilbert space, and then specialize the results to shift-invariant frames with multiple generators. In particular, we present explicit versions of our general conditions for the case of shift-invariant spaces with a single generator. The theory is also adapted to the standard frame setting in which the original and dual frames are defined on the same space.

  2. Strike-slip faults offshore southern Taiwan: implications for the oblique arc-continent collision processes

    Science.gov (United States)

    Fuh, Shi-Chie; Liu, Char-Shine; Lundberg, Neil; Reed, Donald L.

    1997-06-01

    Taiwan is the site of present-day oblique arc-continent collision between the Luzon arc of the Philippine Sea plate and the Chinese continental margin. The major structural pattern revealed from marine geophysical studies in the area offshore southern Taiwan is that of a doubly-vergent orogenic belt, bounded by significant zones of thrusting on the west and east of the submarine accretionary wedge. Due to the oblique collision process, strike-slip faults could play an important role in this convergent domain. Topographic lineaments revealed from new digital bathymetry data and seismic reflection profiles confirm the existence of three sets of strike-slip faults in the collision-subduction zone offshore southern Taiwan: the N-S-trending left-lateral strike-slip faults within the Luzon volcanic arc, the NE-SW-trending right-lateral strike-slip faults across the accretionary wedge, and the NNE-SSW-trending left-lateral strike-slip faults lie in the frontal portion of the accretionary wedge. These strike-slip faults overprint pre-existing folds and thrusts and may convert into oblique thrusts or thrusts as the forearc blocks accrete to the mountain belt. A bookshelf rotation model is used to explain the observed geometrical relationships of these strike-slip fault systems. Based on this model, the counter-clockwise rotation of the forearc blocks in the area offshore southern Taiwan could have caused extrusion of the accretionary wedge material into the forearc basin. The originally continuous forearc basin is thus deformed into several closed and separate proto-collisional basins such as the Southern Longitudinal Trough and Taitung Trough. A tectonic evolution model which emphasizes on the development of various structures at different stages of the oblique arc-continent collision for the Taiwan mountain belt is proposed.

  3. Bursts of electron waves modulated by oblique ion waves

    International Nuclear Information System (INIS)

    Boswell, R.W.

    1984-01-01

    Experimental evidence is presented which shows small packets of electron plasma waves modulated by large amplitude obliquely propagating non-linear ion plasma waves. Very often the whole system is modulated by an oscillation near the ion gyro frequency or its harmonics. The ion waves seem to be similar to those measured in the current carrying auroral plasma. These results suggest that the generation of ion and electron waves in the auroral plasma may be correlated

  4. Planar waveguide laser in Er/Al-doped germanosilicate

    DEFF Research Database (Denmark)

    Guldberg-Kjær, Søren Andreas; Hübner, Jörg; Kristensen, Martin

    1999-01-01

    A singlemode DBR laser is demonstrated in an Er/Al-doped germanosilicate planar waveguide. 0.4 mW of output power has been obtained at 1.553 mu m using internal Bragg reflectors produced by UV-induced index modulations.......A singlemode DBR laser is demonstrated in an Er/Al-doped germanosilicate planar waveguide. 0.4 mW of output power has been obtained at 1.553 mu m using internal Bragg reflectors produced by UV-induced index modulations....

  5. Integration of aerial oblique imagery and terrestrial imagery for optimized 3D modeling in urban areas

    Science.gov (United States)

    Wu, Bo; Xie, Linfu; Hu, Han; Zhu, Qing; Yau, Eric

    2018-05-01

    Photorealistic three-dimensional (3D) models are fundamental to the spatial data infrastructure of a digital city, and have numerous potential applications in areas such as urban planning, urban management, urban monitoring, and urban environmental studies. Recent developments in aerial oblique photogrammetry based on aircraft or unmanned aerial vehicles (UAVs) offer promising techniques for 3D modeling. However, 3D models generated from aerial oblique imagery in urban areas with densely distributed high-rise buildings may show geometric defects and blurred textures, especially on building façades, due to problems such as occlusion and large camera tilt angles. Meanwhile, mobile mapping systems (MMSs) can capture terrestrial images of close-range objects from a complementary view on the ground at a high level of detail, but do not offer full coverage. The integration of aerial oblique imagery with terrestrial imagery offers promising opportunities to optimize 3D modeling in urban areas. This paper presents a novel method of integrating these two image types through automatic feature matching and combined bundle adjustment between them, and based on the integrated results to optimize the geometry and texture of the 3D models generated from aerial oblique imagery. Experimental analyses were conducted on two datasets of aerial and terrestrial images collected in Dortmund, Germany and in Hong Kong. The results indicate that the proposed approach effectively integrates images from the two platforms and thereby improves 3D modeling in urban areas.

  6. Nonlinear interaction between a pair of oblique modes in a supersonic mixing layer: Long-wave limit

    Science.gov (United States)

    Balsa, Thomas F.; Gartside, James

    1995-01-01

    The nonlinear interaction between a pair of symmetric, oblique, and spatial instability modes is studied in the long-wave limit using asymptotic methods. The base flow is taken to be a supersonic mixing layer whose Mach number is such that the corresponding vortex sheet is marginally stable according to Miles' criterion. It is shown that the amplitude of the mode obeys a nonlinear integro-differential equation. Numerical solutions of this equation show that, when the obliqueness angle is less than pi/4, the effect of the nonlinearity is to enhance the growth rate of the instability. The solution terminates in a singularity at a finite streamwise location. This result is reminiscent of that obtained in the vicinity of the neutral point by other authors in several different types of flows. On the other hand, when the obliqueness angle is more than pi/4, the streamwise development of the amplitude is characterized by a series of modulations. This arises from the fact that the nonlinear term in the amplitude equation may be either stabilizing or destabilizing, depending on the value of the streamwise coordinate. However, even in this case the amplitude of the disturbance increases, though not as rapidly as in the case for which the angle is less than pi/4. Quite generally then, the nonlinear interaction between two oblique modes in a supersonic mixing layer enhances the growth of the disturbance.

  7. Asymmetric diffusion model for oblique-incidence reflectometry

    Institute of Scientific and Technical Information of China (English)

    Yaqin Chen; Liji Cao; Liqun Sun

    2011-01-01

    A diffusion theory model induced by a line source distribution is presented for oblique-incidence reflectom-etry. By fitting to this asymmetric diffusion model, the absorption and reduced scattering coefficients μa and μ's of the turbid medium can both be determined with accuracy of 10% from the absolute profile of the diffuse reflectance in the incident plane at the negative position -1.5 transport mean free path (mfp') away from the incident point; particularly, μ's can be estimated from the data at positive positions within 0-1.0 mfp' with 10% accuracy. The method is verified by Monte Carlo simulations and experimentally tested on a phantom.%A diffusion theory model induced by a line source distribution is presented for oblique-incidence reflectometry.By fitting to this asymmetric diffusion model,the absorption and reduced scattering coefficients μa and μ's of the turbid medium can both be determined with accuracy of 10% from the absolute profile of the diffuse reflectance in the incident plane at the negative position -1.5 transport mean free path (mfp')away from the incident point;particularly,μ's can be estimated from the data at positive positions within 0-1.0 mfp' with 10% accuracy.The method is verified by Monte Carlo simulations and experimentally tested on a phantom.Knowledge about the optical properties,including the absorption coefficient (μa) and the reduced scattering coefficient (μ's =μs(1-g)),where μs is the scattering coefficient and g is the anisotropy factor of scattering,of biological tissues plays an important role for optical therapeutic and diagnostic techniques in medicine.

  8. The oblique interface in the right cardiophrenic angle: chest radiographic-CT correlation

    International Nuclear Information System (INIS)

    Kim, Jeung Sook; Lee, Kyung Soo; Choo, Sung Wook; Choo, In Wook

    1996-01-01

    An oblique interface in the right cardiophrenic angle, extending superomedially from right retrocardiac or supradiaphragmatic region inferolaterally to peridiaphragmatic region, is occasionally observed on posteroanterior chest radiograph. The aim of this study was to evaluate the frequency of visualization of the interface on chest radiographs and to elucidate its nature on radiographic-CT correlation. Posteroanterior chest radiographs from 300 consecutive subjects were analyzed to evaluate the frequency and demographic data about an oblique interface in the right cardiophrenic angle. Thin-section CT scans(1-mm collimation and 5-mm intervals) were obtained from the subjects with positive interface on chest radiograph for assessment of the nature of the interface. The demographic data in the subjects with and without the interface were tested statistically to note any difference between two groups. Oblique interface in the right cardiophrenic angle was present in 29 subjects(9.7%) on chest radiograph. The age of the subjects with positive interface(13 men and 16 women) ranged from 19 to 70 years(mean±SD, 47±12.7 years) whereas the age of the subjects without the interface from 16 to 82 years (mean±SD, 50±9.1 years)(p>0.1). The body weight of the subjects with the interface ranged from 41 to 72 Kg(mean±SD, 60±8.0Kg) whereas the body weight of the subjects without the interface from 41 to 85Kg(mean±SD, 63±10.1Kg)(p>0.1). On CT scan, it was formed due to contact between the epipericardial fat and the right middle lobe of the lung in 27 subjects(93%) and between the inferior vena cava and the medial basal segment of the right lower lobe of the lung in two(7%). Oblique interface in the right cardiophrenic angle is occasionally visualized on chest radiograph. It is formed due to contact between the right middle lobe of the lung and pericardial fat in most cases. The frequency of visualization of the interface has no relationship to age and body weight of the

  9. Finite Element Analysis of Doorframe Structure of Single Oblique Pole Type in Container Crane

    Science.gov (United States)

    Cheng, X. F.; Wu, F. Q.; Tang, G.; Hu, X.

    2017-07-01

    Compared with the composite type, the single oblique pole type has more advantages, such as simple structure, thrift steel and high safe overhead clearance. The finite element model of the single oblique pole type is established in nodes by ANSYS, and more details are considered when the model is simplified, such as the section of Girder and Boom, torque in Girder and Boom occurred by Machinery house and Trolley, density according to the way of simplification etc. The stress and deformation of ten observation points are compared and analyzed, when the trolley is in nine dangerous positions. Based on the result of analysis, six dangerous points are selected to provide reference for the detection and evaluation of container crane.

  10. Normal tendon sheath of the second to fifth fingers as seen on oblique views

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, E.

    1984-01-01

    Oblique views of the fingers, using a low kilovolt technique, show a portion of the tendon sheaths which can be regarded as representative of the entire sheath. Because of the varying obliquity of each finger, this proportion differs in the fingers. With increasing age the projected portion of the sheath becomes smaller because it is covered by increasing bone formation in the insertion of the tendon sheat. Normal values have been obtained for adults according to their decades; from these, quite minor degrees of tendon sheat thickening can be determined. In camptodactyly of the fifth finger, which is not uncommon, the tendon sheat may be widened in the absence of a tenosynovitis.

  11. Planar channeling in superlattices: Theory

    International Nuclear Information System (INIS)

    Ellison, J.A.; Picraux, S.T.; Allen, W.R.; Chu, W.K.

    1988-01-01

    The well-known continuum model theory for planar channeled energetic particles in perfect crystals is extended to layered crystalline structures and applied to superlattices. In a strained-layer structure, the planar channels with normals which are not perpendicular to the growth direction change their direction at each interface, and this dramatically influences the channeling behavior. The governing equation of motion for a planar channeled ion in a strained-layer superlattice with equal layer thicknesses is a one degree of freedom nonlinear oscillator which is periodically forced with a sequence of δ functions. These δ functions, which are of equal spacing and amplitude with alternating sign, represent the tilts at each of the interfaces. Thus upon matching an effective channeled particle wavelength, corresponding to a natural period of the nonlinear oscillator, to the period of the strained-layer superlattice, corresponding to the periodic forcing, strong resonance effects are expected. The condition of one effective wavelength per period corresponds to a rapid dechanneling at a well-defined depth (catastrophic dechanneling), whereas two wavelengths per period corresponds to no enhanced dechanneling after the first one or two layers (resonance channeling). A phase plane analysis is used to characterize the channeled particle motion. Detailed calculations using the Moliere continuum potential are compared with our previously described modified harmonic model, and new results are presented for the phase plane evolution, as well as the dechanneling as a function of depth, incident angle, energy, and layer thickness. General scaling laws are developed and nearly universal curves are obtained for the dechanneling versus depth under catastrophic dechanneling

  12. Parallel-fed planar dipole antenna arrays for low-observable platforms

    CERN Document Server

    Singh, Hema; Jha, Rakesh Mohan

    2016-01-01

    This book focuses on determination of scattering of parallel-fed planar dipole arrays in terms of reflection and transmission coefficients at different levels of the array system. In aerospace vehicles, the phased arrays are often in planar configuration. The radar cross section (RCS) of the vehicle is mainly due to its structure and the antennas mounted over it. There can be situation when the signatures due to antennas dominate over the structural RCS of the platform. This necessitates the study towards the reduction and control of antenna/ array RCS. The planar dipole array is considered as a stacked linear dipole array. A systematic, step-by-step approach is used to determine the RCS pattern including the finite dimensions of dipole antenna elements. The mutual impedance between the dipole elements for planar configuration is determined. The scattering till second-level of couplers in parallel feed network is taken into account. The phase shifters are modelled as delay line. All the couplers in the feed n...

  13. A planar microfluidic mixer based on logarithmic spirals

    International Nuclear Information System (INIS)

    Scherr, Thomas; Nandakumar, Krishnaswamy; Quitadamo, Christian; Tesvich, Preston; Park, Daniel Sang-Won; Hayes, Daniel; Monroe, W Todd; Tiersch, Terrence; Choi, Jin-Woo

    2012-01-01

    A passive, planar micromixer design based on logarithmic spirals is presented. The device was fabricated using polydimethylsiloxane soft photolithography techniques, and mixing performance was characterized via numerical simulation and fluorescent microscopy. Mixing efficiency initially declined as the Reynolds number increased, and this trend continued until a Reynolds number of 15 where a minimum was reached at 53%. Mixing efficiency then began to increase reaching a maximum mixing efficiency of 86% at Re = 67. Three-dimensional (3D) simulations of fluid mixing in this design were compared to other planar geometries such as the Archimedes spiral and Meandering-S mixers. The implementation of logarithmic curvature offers several unique advantages that enhance mixing, namely a variable cross-sectional area and a logarithmically varying radius of curvature that creates 3D Dean vortices. These flow phenomena were observed in simulations with multilayered fluid folding and validated with confocal microscopy. This design provides improved mixing performance over a broader range of Reynolds numbers than other reported planar mixers, all while avoiding external force fields, more complicated fabrication processes and the introduction of flow obstructions or cavities that may unintentionally affect sensitive or particulate-containing samples. Due to the planar design requiring only single-step lithographic features, this compact geometry could be easily implemented into existing micro-total analysis systems requiring effective rapid mixing. (paper)

  14. Minimization of Dead-Periods in MRI Pulse Sequences for Imaging Oblique Planes

    Science.gov (United States)

    Atalar, Ergin; McVeigh, Elliot R.

    2007-01-01

    With the advent of breath-hold MR cardiac imaging techniques, the minimization of TR and TE for oblique planes has become a critical issue. The slew rates and maximum currents of gradient amplifiers limit the minimum possible TR and TE by adding dead-periods to the pulse sequences. We propose a method of designing gradient waveforms that will be applied to the amplifiers instead of the slice, readout, and phase encoding waveforms. Because this method ensures that the gradient amplifiers will always switch at their maximum slew rate, it results in the minimum possible dead-period for given imaging parameters and scan plane position. A GRASS pulse sequence has been designed and ultra-short TR and TE values have been obtained with standard gradient amplifiers and coils. For some oblique slices, we have achieved shorter TR and TE values than those for nonoblique slices. PMID:7869900

  15. Nb multilayer planarization technology for a subnanosecond Josephson 1K-bit RAM

    International Nuclear Information System (INIS)

    Nagasawa, S.; Wada, Y.; Tsuge, H.; Hidaka, M.; Ishida, I.; Tahara, S.

    1989-01-01

    Nb multilayer planarization technology has been developed. This planarization technology consists of an etch-back technique using 2000-molecular weight polystyrene and SiO/sub 2/ for the junction layer and wiring layers, and a tapered edge etching technique for contact between individual wiring layers. A Josephson 1K-bit random access memory (RAM) has been fabricated using this planarization technology. Excellent planarity, wherein level differences in all step areas are reduced to less than 1/20th of their original value, was achieved in the multilayer structure of the RAM. Moreover, appropriate RAM operations, with 570ps minimum access time and 13mW power dissipation, were confirmed

  16. Flat panel planar optic display. Revision 4/95

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-05-01

    A prototype 10 inch flat panel Planar Optic display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic glass sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  17. Morphing Planar Graph Drawings with a Polynomial Number of Steps

    DEFF Research Database (Denmark)

    Alamdari, Soroush; Angelini, Patrizio; Chan, Timothy M.

    2013-01-01

    In 1944, Cairns proved the following theorem: given any two straight-line planar drawings of a triangulation with the same outer face, there exists a morph (i.e., a continuous transformation) between the two drawings so that the drawing remains straight-line planar at all times. Cairns’s original...

  18. Improved detection of sentinel lymph nodes in SPECT/CT images acquired using a low- to medium-energy general-purpose collimator.

    Science.gov (United States)

    Yoneyama, Hiroto; Tsushima, Hiroyuki; Kobayashi, Masato; Onoguchi, Masahisa; Nakajima, Kenichi; Kinuya, Seigo

    2014-01-01

    The use of the low-energy high-resolution (LEHR) collimator for lymphoscintigraphy causes the appearance of star-shaped artifacts at injection sites. The aim of this study was to confirm whether the lower resolution of the low- to medium-energy general-purpose (LMEGP) collimator is compensated by decrease in the degree of septal penetration and the reduction in star-shaped artifacts. A total of 106 female patients with breast cancer, diagnosed by biopsy, were enrolled in this study. Tc phytate (37 MBq, 1 mCi) was injected around the tumor, and planar and SPECT/CT images were obtained after 3 to 4 hours. When sentinel lymph nodes (SLNs) could not be identified from planar and SPECT/CT images by using the LEHR collimator, we repeated the study with the LMEGP collimator. Planar imaging performed using the LEHR and LEHR + LMEGP collimators positively identified SLNs in 96.2% (102/106) and 99.1% (105/106) of the patients, respectively. Using combination of planar and SPECT/CT imaging with the LEHR and LEHR + LMEGP collimators, SLNs were positively identified in 97.2% (103/106) and 100% (106/106) of the patients, respectively. The LMEGP collimator provided better results than the LEHR collimator because of the lower degree of septal penetration. The use of the LMEGP collimator improved SLN detection.

  19. An automatic scaling method for obtaining the trace and parameters from oblique ionogram based on hybrid genetic algorithm

    Science.gov (United States)

    Song, Huan; Hu, Yaogai; Jiang, Chunhua; Zhou, Chen; Zhao, Zhengyu; Zou, Xianjian

    2016-12-01

    Scaling oblique ionogram plays an important role in obtaining ionospheric structure at the midpoint of oblique sounding path. The paper proposed an automatic scaling method to extract the trace and parameters of oblique ionogram based on hybrid genetic algorithm (HGA). The extracted 10 parameters come from F2 layer and Es layer, such as maximum observation frequency, critical frequency, and virtual height. The method adopts quasi-parabolic (QP) model to describe F2 layer's electron density profile that is used to synthesize trace. And it utilizes secant theorem, Martyn's equivalent path theorem, image processing technology, and echoes' characteristics to determine seven parameters' best fit values, and three parameter's initial values in QP model to set up their searching spaces which are the needed input data of HGA. Then HGA searches the three parameters' best fit values from their searching spaces based on the fitness between the synthesized trace and the real trace. In order to verify the performance of the method, 240 oblique ionograms are scaled and their results are compared with manual scaling results and the inversion results of the corresponding vertical ionograms. The comparison results show that the scaling results are accurate or at least adequate 60-90% of the time.

  20. Development of a Planar Undulator

    International Nuclear Information System (INIS)

    Deyhim, Alex; Johnson, Eric; Kulesza, Joe; Lyndaker, Aaron; Waterman, Dave; Eisert, Dave; Green, Michael A.; Rogers, Greg; Blomqvist, K. Ingvar

    2007-01-01

    The design of a planar pure permanent magnet undulator is presented. The design requirements and mechanical difficulties for holding, positioning, and driving the magnetic arrays are explored. The structural, thermal, and electrical considerations that influenced the design are then analyzed. And finally detailed magnetic measurements are presented

  1. Poling of Planar Silica Waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Kristensen, Martin; Jensen, Jesper Bo

    1999-01-01

    UV-written planar silica waveguides are poled using two different poling techniques, thermal poling and UV-poling. Thermal poling induces an electro-optic coefficient of 0.067 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. The induced electro-optic effect shows a linear dependence...

  2. Recent Studies on the Aromaticity and Antiaromaticity of Planar Cyclooctatetraene

    Directory of Open Access Journals (Sweden)

    Masahiko Iyoda

    2010-02-01

    Full Text Available Cyclooctatetraene (COT, the first 4nπ-electron system to be studied, adopts an inherently nonplanar tub-shaped geometry of D2d symmetry with alternating single and double bonds, and hence behaves as a nonaromatic polyene rather than an antiaromatic compound. Recently, however, considerable 8π-antiaromatic paratropicity has been shown to be generated in planar COT rings even with the bond alternated D4h structure. In this review, we highlight recent theoretical and experimental studies on the antiaromaticity of hypothetical and actual planar COT. In addition, theoretically predicted triplet aromaticity and stacked aromaticity of planar COT are also briefly described.

  3. Dynamic Planar Convex Hull

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølfting; Jacob, Rico

    2002-01-01

    In this paper we determine the computational complexity of the dynamic convex hull problem in the planar case. We present a data structure that maintains a finite set of n points in the plane under insertion and deletion of points in amortized O(log n) time per operation. The space usage of the d......In this paper we determine the computational complexity of the dynamic convex hull problem in the planar case. We present a data structure that maintains a finite set of n points in the plane under insertion and deletion of points in amortized O(log n) time per operation. The space usage...... of the data structure is O(n). The data structure supports extreme point queries in a given direction, tangent queries through a given point, and queries for the neighboring points on the convex hull in O(log n) time. The extreme point queries can be used to decide whether or not a given line intersects...... the convex hull, and the tangent queries to determine whether a given point is inside the convex hull. We give a lower bound on the amortized asymptotic time complexity that matches the performance of this data structure....

  4. Spectroelectrochemical sensing: planar waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Ross, Susan E.; Shi Yining; Seliskar, Carl J.; Heineman, William R

    2003-09-30

    The spectroelectrochemical sensor combines in a single device electrochemistry, spectroscopy, and selective partitioning into a film, giving improved selectivity for applications that involve complex samples. Sensing is based on the change in optical signal that accompanies electrochemical modulation of analyte that has partitioned into the film. Two classes of optical quality chemically-selective films based on two different host materials, namely, sol-gel processed silica and cross-linked poly(vinyl alcohol) have been developed. Films are typically 400-700 nm thick. Three types of sensor platforms are discussed: a multiple internal reflection (MIR) optic consisting of a bilayer of an indium tin oxide (ITO) optically transparent electrode deposited on a 1-mm thick glass substrate, a planar waveguide in which a potassium ion-exchanged BK7 glass waveguide (5-9 {mu}m thick) was over-coated with a thin film of ITO, and a planar waveguide in which a potassium ion-exchanged BK7 glass waveguide channel was formed and a pair of electrodes deposited along side the channel. These sensors were evaluated with ferrocyanide and a selective film of PDMDAAC-SiO{sub 2}, where PDMDAAC=poly(dimethyl diallylammonium chloride)

  5. Spectroelectrochemical sensing: planar waveguides

    International Nuclear Information System (INIS)

    Ross, Susan E.; Shi Yining; Seliskar, Carl J.; Heineman, William R.

    2003-01-01

    The spectroelectrochemical sensor combines in a single device electrochemistry, spectroscopy, and selective partitioning into a film, giving improved selectivity for applications that involve complex samples. Sensing is based on the change in optical signal that accompanies electrochemical modulation of analyte that has partitioned into the film. Two classes of optical quality chemically-selective films based on two different host materials, namely, sol-gel processed silica and cross-linked poly(vinyl alcohol) have been developed. Films are typically 400-700 nm thick. Three types of sensor platforms are discussed: a multiple internal reflection (MIR) optic consisting of a bilayer of an indium tin oxide (ITO) optically transparent electrode deposited on a 1-mm thick glass substrate, a planar waveguide in which a potassium ion-exchanged BK7 glass waveguide (5-9 μm thick) was over-coated with a thin film of ITO, and a planar waveguide in which a potassium ion-exchanged BK7 glass waveguide channel was formed and a pair of electrodes deposited along side the channel. These sensors were evaluated with ferrocyanide and a selective film of PDMDAAC-SiO 2 , where PDMDAAC=poly(dimethyl diallylammonium chloride)

  6. Magnetoelastic bending and snapping of ferromagnetic plates in oblique magnetic fields

    International Nuclear Information System (INIS)

    Zhou Youhe

    1995-01-01

    Ferritic stainless steel has been considered for structural components such as first walls and blankets of fusion power reactors because the material shows low rates of irradiation swelling. Since it is magnetizable, the magnetoelastic interaction between magnetic field and deformation of the structures in a fusion reactor is so strong that their safety is of concern due to the magnetoelastic bending, buckling and magnetic damping, etc. Basic research of the magnetoelastic characteristics of ferromagnetic plate has been paid special attention by researchers. In this paper, the magnetoelastic bending and snapping are studied for a ferromagnetic plate in an oblique magnetic field. The theoretical model is based on the variational principle where the functional is employed as real total energy in the system including external work. The obtained expression of magnetic force on the plate is the same as that derived from the dipole model when the total magnetic field in the ferromagnetic medium is considered. In order to effectively solve the nonlinearly coupled interaction problem between magnetic field and mechanical deformation, a numerical program combining the finite element method for analyzing the magnetic field with the finite difference technique for finding out the bending deformation of the plate is employed to obtain the solution of magnetoelastic bending of a soft ferromagnetic plate. The numerical calculations are carried out for the typical example of a ferromagnetic cantilevered beam-plate in an oblique magnetic field. From the bending curves, that is the tip deflection versus applied magnetic fields, the critical magnetic field for the magnetoelastic snapping is predicted by the Southwell plot. The theoretical predictions show that the critical magnetic field decreases with the increase in incident angle of the oblique magnetic field. By the effect of incident angle on the magnetic buckling, the discrepancy between theoretical and experimental data can

  7. Transition of W7-X non-planar coils from manufacturing to assembly

    Energy Technology Data Exchange (ETDEWEB)

    Ehrke, G. [Max-Planck-Institut fuer Plasmaphysik (IPP), EURATOM Association, Wendelsteinstrasse 1, D-17491 Greifswald (Germany)], E-mail: gunnar.ehrke@ipp.mpg.de

    2009-06-15

    The main magnetic field of Wendelstein 7-X fusion experiment (W7-X) at Max-Planck-Institut fuer Plasmaphysik Greifswald, Germany will be provided by 50 non-planar coils and supported by 20 planar coils. The non-planar coils were delivered by a consortium (CON) consisting of Babcock Noell GmbH Germany (BNG) and ASG Superconductors S.p.A. Italy (ASG). The coil production ended with the delivery of the last non-planar coil in March 2008 at the manufacturing branch of BNG in Zeitz, Germany. The construction of the coils was characterised by design changes, many rework actions and resulting time delays. Due to these numerous adjustments and changes a continuous improvement process was needed. This paper will give an overview about the transition of the non-planar coils from the acceptance tests at the manufacturer site to the beginning of the assembly at IPP. Furthermore this report will highlight technical interfaces in the period of transition.

  8. Paving the Way Towards Reactive Planar Spanner Construction in Wireless Networks

    Science.gov (United States)

    Frey, Hannes; Rührup, Stefan

    A spanner is a subgraph of a given graph that supports the original graph's shortest path lengths up to a constant factor. Planar spanners and their distributed construction are of particular interest for geographic routing, which is an efficient localized routing scheme for wireless ad hoc and sensor networks. Planarity of the network graph is a key criterion for guaranteed delivery, while the spanner property supports efficiency in terms of path length. We consider the problem of reactive local spanner construction, where a node's local topology is determined on demand. Known message-efficient reactive planarization algorithms do not preserve the spanner property, while reactive spanner constructions with a low message overhead have not been described so far. We introduce the concept of direct planarization which may be an enabler of efficient reactive spanner construction. Given an edge, nodes check for all incident intersecting edges a certain geometric criterion and withdraw the edge if this criterion is not satisfied. We use this concept to derive a generic reactive topology control mechanism and consider two geometric criteria. Simulation results show that direct planarization increases the performance of localized geographic routing by providing shorter paths than existing reactive approaches.

  9. Stress and slip partitioning during oblique rifting: comparison between data from the Main Ethiopian Rift and laboratory experiments

    Science.gov (United States)

    Corti, G.; Philippon, M.; Sani, F.; Keir, D.

    2012-04-01

    Oblique rifting in the central and northern Main Ethiopian Rift (MER) has resulted in a complex structural pattern characterized by two differently oriented fault systems: a set of NE-SW-trending boundary faults and a system of roughly NNE-SSW-oriented fault swarms affecting the rift floor (Wonji faults). Boundary faults formed oblique to the regional extension vector, likely as a result of the oblique reactivation of a pre-existing deep-seated rheological anisotropy, whereas internal Wonji faults developed sub-orthogonal to the stretching direction. Previous works have successfully reconciled this rift architecture and fault distribution with the long-term plate kinematics; however, at a more local scale, fault-slip and earthquake data reveal significant variations in the orientation the minimum principal stress and related fault-slip direction across the rift valley. Whereas fault measurements indicate a roughly N95°E extension on the axial Wonji faults, a N105°E to N110°E directed minimum principal stress is observed along boundary faults. Both fault-slip data and analysis of seismicity indicate a roughly pure dip-slip motion on the boundary faults, despite their orientation (oblique to the regional extension vector) should result in an oblique displacement. To shed light on the process driving the variability of data derived from fault-slip (and seismicity) analysis we present crustal-scale analogue models of oblique rifting, deformed in a large-capacity centrifuge by using materials and boundary conditions described in several previous modeling works. As in these previous works, the experiments show the diachronous activation of two fault systems, boundary and internal, whose pattern strikingly resemble that observed in previous lithospheric-scale modeling, as well as that described in the MER. Internal faults arrange in two different, en-echelon segments connected by a transfer zone where strike-slip displacement dominates. Whereas internal faults develop

  10. Horizontal effect of the surgical weakening of the oblique muscles

    Directory of Open Access Journals (Sweden)

    Carlos Souza-Dias

    2011-06-01

    Full Text Available PURPOSE: To evaluate the influence of the oblique muscles surgical weakening on the horizontal alignment in the primary position (PP and its efficacy on the correction of the "A" and "V" anisotropies. METHODS: In order to study the influence of bilateral superior oblique muscles (SO weakening on the horizontal alignment in PP, we analyzed the files of 12 patients who underwent only that operation; no other muscle was operated on. We took the opportunity of those 12 patients to analyze the effect of their operation on the correction of "A" incomitance. For evaluating the effect of the inferior oblique muscles (IO weakening on the correction of the "V" pattern, we analyzed retrospectively the files of 67 anisotropic patients who underwent a bilateral SO weakening. In 10 of them, the only operation was the oblique muscles weakening and, in 57 patients, the horizontal recti were also operated on for the horizontal deviations in primary position. These patients were divided into two groups: 50 were esotropic and 17 exotropic. There was not any mixed anisotropy. RESULTS: The mean value of the preoperative "V" incomitance of the 50 esotropic patients was 24.25∆ ± 10.15∆; the mean postoperative correction was 15.56 ∆ ± 8.74∆. The mean correction between the PP and upgaze was 7.52∆ ± 7.47∆ and from the PP to downgaze was 8.56∆ ± 9.21∆. The same values of the 17 exotropic patients was: preoperative 31.88∆ ± 9.4∆; primary position to upgaze was 13.11∆ ± 4.9∆ and primary position to downgaze 14.11∆ ± 12.48∆. The mean preoperative value of the "A" incomitance among the 12 patients who underwent isolated SO weakening was 30.50∆ ± 19.25∆ and the postoperative was of 9,92∆, therefore a mean correction of 22.58∆ ± 17.54∆. Among these ones, in 5 there was no alteration of the deviation in primary position, in 4 there was an exo-effect and in 3 there was an eso-effect. The mean alteration of the deviation in PP was an

  11. Historical oblique aerial photographs as a powerful tool for communicating landscape changes

    DEFF Research Database (Denmark)

    Svenningsen, Stig Roar; Brandt, Jesper; Christensen, Andreas Aagaard

    2015-01-01

    This paper reports on a potential new form of data generation and data display to be used for communicating landscape change at local scales, utilizing a huge collection of oblique aerial photographs held by the Royal Library in Copenhagen. The collection contains local scale imagery covering all...

  12. Planar and non-planar nucleus-acoustic shock structures in self-gravitating degenerate quantum plasma systems

    Science.gov (United States)

    Zaman, D. M. S.; Amina, M.; Dip, P. R.; Mamun, A. A.

    2017-11-01

    The basic properties of planar and non-planar (spherical and cylindrical) nucleus-acoustic (NA) shock structures (SSs) in a strongly coupled self-gravitating degenerate quantum plasma system (containing strongly coupled non-relativistically degenerate heavy nuclear species, weakly coupled non-relativistically degenerate light nuclear species, and inertialess non-/ultra-relativistically degenerate electrons) have been investigated. The generalized quantum hydrodynamic model and the reductive perturbation method have been used to derive the modified Burgers equation. It is shown that the strong correlation among heavy nuclear species acts as the source of dissipation and is responsible for the formation of the NA SSs with positive (negative) electrostatic (self-gravitational) potential. It is also observed that the effects of non-/ultra-relativistically degenerate electron pressure, dynamics of non-relativistically degenerate light nuclear species, spherical geometry, etc., significantly modify the basic features of the NA SSs. The applications of our results in astrophysical compact objects like white dwarfs and neutron stars are briefly discussed.

  13. A comparison of oblique subcostal transversus abdominis plane block versus thoracic paravertebral block for postoperative analgesia after open cholecystectomy

    Directory of Open Access Journals (Sweden)

    Ghada Kamhawy

    2017-10-01

    Full Text Available Background: A major challenge in the postoperative period is pain management which, if not adequately controlled, may contribute to patient discomfort and decreased patient satisfaction, and possibly increased morbidity and mortality. Both Thoracic paravertebral block and oblique subcostal transversus abdominis plane block can be used as analgesic techniques for abdominal surgeries. Our aim in this research was comparison of cumulative 24-h post-operative morphine consumption between ultrasound-guided oblique subcostal transversus abdominis plane block and ultrasound-guided thoracic paravertebral block in patients who underwent an open cholecystectomy under general anesthesia. Patients and methods: This study was performed on 46 patients who underwent open cholecystectomy under general anesthesia. All patients were randomly allocated alternatively to one of two equal groups to either undergo ultrasound-guided unilateral oblique subcostal transversus abdominis plane block Group (I or to undergo ultrasound-guided unilateral thoracic paravertebral block Group (II. Both groups were subjected to a similar analgesic regimen in the immediate post-operative period that involved intravenous patient-controlled morphine analgesia which was used in both groups. Results: The total morphine consumption in the first postoperative 24 h was lower in thoracic paravertebral block Group (II (9.9 mg in thoracic paravertebral block group vs. 15.4 mg in oblique subcostal transversus abdominis plane block Group (I with p < 0.001. The mean time of first request of analgesia in Group (I was 248.7 min compared to 432.1 for Group (II with p < 0.001. Conclusions: Both ultrasound-guided oblique subcostal transversus abdominis plain block and single injection ultrasound guided thoracic paravertebral block are effective analgesic techniques for upper abdominal surgeries and reduces postoperative opioid requirements. However, thoracic paravertebral block is more

  14. Recognition of human gait in oblique and frontal views using Kinect ...

    African Journals Online (AJOL)

    This study describes the recognition of human gait in the oblique and frontal views using novel gait features derived from the skeleton joints provided by Kinect. In D-joint, the skeleton joints were extracted directly from the Kinect, which generates the gait feature. On the other hand, H-joint distance is a feature of distance ...

  15. A LOW STELLAR OBLIQUITY FOR WASP-47, A COMPACT MULTIPLANET SYSTEM WITH A HOT JUPITER AND AN ULTRA-SHORT PERIOD PLANET

    Energy Technology Data Exchange (ETDEWEB)

    Sanchis-Ojeda, Roberto; Isaacson, Howard; Marcy, Geoffrey W.; Weiss, Lauren [Department of Astronomy, University of California, Berkeley, CA 94720 (United States); Winn, Joshua N.; Dai, Fei [Department of Physics, and Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Howard, Andrew W.; Sinukoff, Evan [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States); Petigura, Erik; Rogers, Leslie [Department of Astronomy and Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States); Albrecht, Simon [Stellar Astrophysics Centre, Department of Physics and Astronomy, Aarhus University, Ny Munkegade 120, DK-8000 Aarhus C (Denmark); Hirano, Teruyuki, E-mail: sanchisojeda@berkeley.edu [Department of Earth and Planetary Sciences, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8551 (Japan)

    2015-10-10

    We have detected the Rossiter–Mclaughlin effect during a transit of WASP-47b, the only known hot Jupiter with close planetary companions. By combining our spectroscopic observations with Kepler photometry, we show that the projected stellar obliquity is λ = 0° ± 24°. We can firmly exclude a retrograde orbit for WASP-47b, and rule out strongly misaligned prograde orbits. Low obliquities have also been found for most of the other compact multiplanet systems that have been investigated. The Kepler-56 system, with two close-in gas giants transiting their subgiant host star with an obliquity of at least 45{sup ◦}, remains the only clear counterexample.

  16. Advection endash diffusion past a strip. II. Oblique incidence

    International Nuclear Information System (INIS)

    Knessl, C.; Keller, J.B.

    1997-01-01

    Advection and diffusion of particles past an impenetrable strip is considered when the strip is oblique to the advection or drift velocity. The particle concentration p(x,y) is determined asymptotically for large values of vL/D, where v is the drift velocity, D is the diffusion coefficient, and 2L is the width of the strip. The results complement those of Part I, which treated a strip normal to the drift velocity. copyright 1997 American Institute of Physics

  17. Automated curved planar reformation of 3D spine images

    International Nuclear Information System (INIS)

    Vrtovec, Tomaz; Likar, Bostjan; Pernus, Franjo

    2005-01-01

    Traditional techniques for visualizing anatomical structures are based on planar cross-sections from volume images, such as images obtained by computed tomography (CT) or magnetic resonance imaging (MRI). However, planar cross-sections taken in the coordinate system of the 3D image often do not provide sufficient or qualitative enough diagnostic information, because planar cross-sections cannot follow curved anatomical structures (e.g. arteries, colon, spine, etc). Therefore, not all of the important details can be shown simultaneously in any planar cross-section. To overcome this problem, reformatted images in the coordinate system of the inspected structure must be created. This operation is usually referred to as curved planar reformation (CPR). In this paper we propose an automated method for CPR of 3D spine images, which is based on the image transformation from the standard image-based to a novel spine-based coordinate system. The axes of the proposed spine-based coordinate system are determined on the curve that represents the vertebral column, and the rotation of the vertebrae around the spine curve, both of which are described by polynomial models. The optimal polynomial parameters are obtained in an image analysis based optimization framework. The proposed method was qualitatively and quantitatively evaluated on five CT spine images. The method performed well on both normal and pathological cases and was consistent with manually obtained ground truth data. The proposed spine-based CPR benefits from reduced structural complexity in favour of improved feature perception of the spine. The reformatted images are diagnostically valuable and enable easier navigation, manipulation and orientation in 3D space. Moreover, reformatted images may prove useful for segmentation and other image analysis tasks

  18. AUTOMATIC ORIENTATION OF LARGE BLOCKS OF OBLIQUE IMAGES

    Directory of Open Access Journals (Sweden)

    E. Rupnik

    2013-05-01

    Full Text Available Nowadays, multi-camera platforms combining nadir and oblique cameras are experiencing a revival. Due to their advantages such as ease of interpretation, completeness through mitigation of occluding areas, as well as system accessibility, they have found their place in numerous civil applications. However, automatic post-processing of such imagery still remains a topic of research. Configuration of cameras poses a challenge on the traditional photogrammetric pipeline used in commercial software and manual measurements are inevitable. For large image blocks it is certainly an impediment. Within theoretical part of the work we review three common least square adjustment methods and recap on possible ways for a multi-camera system orientation. In the practical part we present an approach that successfully oriented a block of 550 images acquired with an imaging system composed of 5 cameras (Canon Eos 1D Mark III with different focal lengths. Oblique cameras are rotated in the four looking directions (forward, backward, left and right by 45° with respect to the nadir camera. The workflow relies only upon open-source software: a developed tool to analyse image connectivity and Apero to orient the image block. The benefits of the connectivity tool are twofold: in terms of computational time and success of Bundle Block Adjustment. It exploits the georeferenced information provided by the Applanix system in constraining feature point extraction to relevant images only, and guides the concatenation of images during the relative orientation. Ultimately an absolute transformation is performed resulting in mean re-projection residuals equal to 0.6 pix.

  19. Conservation of Planar Polarity Pathway Function Across the Animal Kingdom.

    Science.gov (United States)

    Hale, Rosalind; Strutt, David

    2015-01-01

    Planar polarity is a well-studied phenomenon resulting in the directional coordination of cells in the plane of a tissue. In invertebrates and vertebrates, planar polarity is established and maintained by the largely independent core and Fat/Dachsous/Four-jointed (Ft-Ds-Fj) pathways. Loss of function of these pathways can result in a wide range of developmental or cellular defects, including failure of gastrulation and problems with placement and function of cilia. This review discusses the conservation of these pathways across the animal kingdom. The lack of vital core pathway components in basal metazoans suggests that the core planar polarity pathway evolved shortly after, but not necessarily alongside, the emergence of multicellularity.

  20. Oblique projections and standard-form transformations for discrete inverse problems

    DEFF Research Database (Denmark)

    Hansen, Per Christian

    2013-01-01

    This tutorial paper considers a specific computational tool for the numerical solution of discrete inverse problems, known as the standard-form transformation, by which we can treat general Tikhonov regularization problems efficiently. In the tradition of B. N. Datta's expositions of numerical li...... linear algebra, we use the close relationship between oblique projections, pseudoinverses, and matrix computations to derive a simple geometric motivation and algebraic formulation of the standard-form transformation....

  1. Optically amplifying planar glass waveguides: Laser on a chip

    DEFF Research Database (Denmark)

    Guldberg-Kjær, Søren Andreas

    with UV-light and that permanent Bragg-gratings can be induced. Planar waveguide lasers with integrated Bragg-gratings are manufactured and characterised. It is shown that linewidths below 125 kHz and output powers around 0.5 mW can be obtained, and that the manufactured lasers are resistant to mechanical...... lightwave circuits, as well as provide the gain medium for integrated planar waveguide lasers. The work and the obtained results are presented in this thesis: The manufacturing of silica thin films is described and it is shown that the refractive index of the films can be controlled by germanium co...... as well as thermal influence. A simple method for producing an array of planar waveguide lasers is presented and it is shown that the difference in output wavelength of the individual lasers can be controlled with great accuracy....

  2. Planar waveguide amplifiers and laser in erbium doped silica

    DEFF Research Database (Denmark)

    Guldberg-Kjær, Søren Andreas; Kristensen, Martin

    1999-01-01

    with UV-light and that permanent Bragg-gratings can be induced. Planar waveguide lasers with integrated Bragg-gratings are manufactured and characterised. It is shown that linewidths below 125 kHz and output powers around 0.5 mW can be obtained, and that the manufactured lasers are resistant to mechanical...... lightwave circuits, as well as provide the gain medium for integrated planar waveguide lasers. The work and the obtained results are presented in this thesis: The manufacturing of silica thin films is described and it is shown that the refractive index o fthe films can be controlled by germanium co...... as well as thermal influence. A simple method for producing an array of planar waveguide lasers is presented and it is shown that the difference in output wavelength of the individual lasers can be controlled with great accuracy....

  3. Contribution of thin slice (1 mm) oblique coronal proton density-weighted MR images for assessment of anteromedial and posterolateral bundle damage in anterior cruciate ligament injuries

    Energy Technology Data Exchange (ETDEWEB)

    Gokalp, Gokhan, E-mail: drgokhangokalp@yahoo.com [Department of Radiology, Uludag University Medical Faculty, Gorukle, Bursa (Turkey); Demirag, Burak, E-mail: bdemirag@uludag.edu.tr [Department of Orthopedy, Uludag University Medical Faculty, Gorukle, Bursa (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Department of Radiology, Uludag University Medical Faculty, Gorukle, Bursa (Turkey); Aydemir, Mehmet Fatih, E-mail: fatiha@yahoo.com [Department of Orthopedy, Uludag University Medical Faculty, Gorukle, Bursa (Turkey); Yazici, Zeynep, E-mail: zyazici@uludag.edu.tr [Department of Radiology, Uludag University Medical Faculty, Gorukle, Bursa (Turkey)

    2012-09-15

    Purpose: To evaluate the diagnostic efficacy of using additional oblique coronal 1 mm proton density-weighted (PDW) MR imaging of the knee for detection and grading anterior cruciate ligament (ACL), anteromedial bundle (AMB) and posterolateral bundle (PLB) injuries. Materials and methods: We prospectively assessed preoperative MR images of 50 patients (36 men, 14 women; age range, 18–62 years). First, we compared the diagnostic performance of routine sagittal (3 mm) and additional oblique coronal images (1 mm) for ACL tears. Then, we compared the tear types (AMB or PLB) and grade presumed from oblique coronal MR imaging with arthroscopy. Results: Arthroscopy revealed ACL tear in 24 (48%) patients. There was significant difference between sagittal images and arthroscopy results for ACL tear recognition (p < 0.001). No significant difference was detected for oblique coronal images when compared with arthroscopy results (p = 0.180). Sensitivity and specificity values for ACL tear diagnosis were 37.04% and 95.65% for sagittal images; 74.07% and 91.30% for oblique coronal images. There was no significant difference between arthroscopy and oblique coronal MR images in grading AMB and PLB injuries (p > 0.05). Conclusion: Addition of thin slice oblique coronal images to conventional sequences could better contribute to better verifying the presence of ACL tear and in determining its grade.

  4. Growth and characterization of textured well-faceted ZnO on planar Si(100, planar Si(111, and textured Si(100 substrates for solar cell applications

    Directory of Open Access Journals (Sweden)

    Chin-Yi Tsai

    2017-09-01

    Full Text Available In this work, textured, well-faceted ZnO materials grown on planar Si(100, planar Si(111, and textured Si(100 substrates by low-pressure chemical vapor deposition (LPCVD were analyzed by X-ray diffraction (XRD, scanning electron microscopy (SEM, atomic force microscopy (AFM, and cathode luminescence (CL measurements. The results show that ZnO grown on planar Si(100, planar Si(111, and textured Si(100 substrates favor the growth of ZnO(110 ridge-like, ZnO(002 pyramid-like, and ZnO(101 pyramidal-tip structures, respectively. This could be attributed to the constraints of the lattice mismatch between the ZnO and Si unit cells. The average grain size of ZnO on the planar Si(100 substrate is slightly larger than that on the planar Si(111 substrate, while both of them are much larger than that on the textured Si(100 substrate. The average grain sizes (about 10–50 nm of the ZnO grown on the different silicon substrates decreases with the increase of their strains. These results are shown to strongly correlate with the results from the SEM, AFM, and CL as well. The reflectance spectra of these three samples show that the antireflection function provided by theses samples mostly results from the nanometer-scaled texture of the ZnO films, while the micrometer-scaled texture of the Si substrate has a limited contribution. The results of this work provide important information for optimized growth of textured and well-faceted ZnO grown on wafer-based silicon solar cells and can be utilized for efficiency enhancement and optimization of device materials and structures, such as heterojunction with intrinsic thin layer (HIT solar cells.

  5. Drawing ability in typical and atypical development; colour cues and the effect of oblique lines.

    Science.gov (United States)

    Farran, E K; Dodd, G F

    2015-06-01

    Individuals with Williams syndrome (WS) have poor drawing ability. Here, we investigated whether colour could be used as a facilitation cue during a drawing task. Participants with WS and non-verbal ability matched typically developing (TD) children were shown line figures presented on a 3 by 3 dot matrix, and asked to replicate the figures by drawing on an empty dot matrix. The dots of the matrix were either all black (control condition), or nine different coloured dots (colour condition). In a third condition, which also used coloured dots, participants were additionally asked to verbalise the colours of the dots prior to replicating the line drawings (colour-verbal condition). Performance was stronger in both WS and TD groups on the two coloured conditions, compared with the control condition. However, the facilitation effect of colour was significantly weaker in the WS group than in the TD group. Replication of oblique line segments was less successful than replication of non-oblique line segments for both groups; this effect was reduced by colour facilitation in the TD group only. Verbalising the colours had no additional impact on performance in either group. We suggest that colour acted as a cue to individuate the dots, thus enabling participants to better ascertain the spatial relationships between the parts of each figure, to determine the start and end points of component lines, and to determine the correspondence between the model and their replication. The reduced facilitation in the WS group is discussed in relation to the effect of oblique versus non-oblique lines, the use of atypical drawing strategies, and reduced attention to the model when drawing the replication. © 2014 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.

  6. Magnetic properties of permalloy films with different thicknesses deposited onto obliquely sputtered Cu underlayers

    International Nuclear Information System (INIS)

    Li, Xiaoyu; Sun, Xiaojun; Wang, Jianbo; Liu, Qingfang

    2015-01-01

    In this work, the influence of obliquely sputtered Cu underlayer of 10 nm on the magnetic properties of normally sputtered Permalloy thin films with different thicknesses from 10 nm to 150 nm has been investigated. It has been found that the samples with the Permalloy layer thickness ranging from 10 nm to 70 nm exhibit a good in-plane uniaxial magnetic anisotropy, and the increase of the film thickness leads to a decrease of the anisotropy field and the natural resonance frequency. The critical Permalloy layer thickness for stripe domain initiation of these films is about 80 nm, which is thinner than that of obliquely sputtered Permalloy thin films without an underlayer. The characteristic shapes of hysteresis loops which can be called ''transcritical'' are observed above the critical thickness. The condition and mechanism of appearing stripe domain structure were discussed and it has been found that the frequency response of permeability of the anisotropic films shows the characteristics of multi-peak resonance. - Highlights: • Py films were fabricated on obliquely sputtered Cu underlayers by RF magnetron sputtering. • Effects of Py layer thickness on anisotropy, ferromagnetic resonance frequency have been studied. • Samples with Py layer (<70 nm) show a good in-plane uniaxial magnetic anisotropy. • Samples with Py layer (>80 nm) show stripe domains and multi-peaks in permeability spectra

  7. $1$-string $B_2$-VPG representation of planar graphs

    Directory of Open Access Journals (Sweden)

    Therese Biedl

    2016-09-01

    Full Text Available In this paper, we prove that every planar graph has a 1-string $B_2$-VPG representation—a string representation using paths in a rectangular grid that contain at most two bends. Furthermore, two paths representing vertices $u,v$ intersect precisely once whenever there is an edge between $u$ and $v$. We also show that only a subset of the possible curve shapes is necessary to represent $4$-connected planar graphs.

  8. Breast compression and radiation dose in two different mammographic oblique projections: 45 and 60 deg

    International Nuclear Information System (INIS)

    Brnic, Zoran; Hebrang, Andrija

    2001-01-01

    Introduction: Standard mammography includes two views, craniocaudal and medio-lateral oblique. Depending on patient's body constitution, central beam angle in mediolateral oblique projection may vary, with 45 deg. being suitable for the majority of patients in routine daily practice. With continuous improvement in X-ray technology and radiographers' training, the risk of radiation induced cancerogenesis is considerably reduced and acceptable when compared to benefit. However, the risk still exists, being cumulative and directly related to absorbed glandular dose. There is no minimal dose of radiation which is absolutely harmless, and every effort to reduce the dose is welcome. In this retrospective study two different angles (45 vs. 60 deg.) of mediolateral oblique view were compared according to radiation dose and efficacy of breast compression. Patients and methods: In 52 women, additional 60 deg. oblique films were done after craniocaudal and mediolateral oblique 45 deg.-films, with the same kVp and positioning technique. Breast thickness, time-current products (mA s) and absorbed doses were compared between 45 deg. - and 60 deg.-films. Subgroups of women with large, small, prominent and pendulous breasts were analyzed separately, following the same methodology as for the whole group. Results: mA s were 11.5% lower and compression 7% better with an angle of 60 deg. than with 45 deg. In the subgroup of women with small breasts, mA s values were 13% lower and compression 9% better with 60 deg. than with 45 deg., while in the subgroup with large breasts, mA s were 9% lower and compression 5% better. In the subgroup of patients with pendulous breasts, mA s values were 12% lower and compression 10% better with 60 deg. than with 45 deg., while in the subgroup with prominent breasts, mA s values were 4% lower and compression 3% better. Absorbed glandular dose was estimated to be approximately 20% lower when an oblique mammogram was done with 60 deg. instead of 45 deg

  9. Short linear shadows connecting pulmonary segmental arteries to oblique fissures in volumetric thin-section CT images: comparing CT, micro-CT and histopathology

    International Nuclear Information System (INIS)

    Guan, Chun-Shuang; Ma, Da-Qing; Chen, Jiang-Hong; Chen, Bu-Dong; Cui, Dun; Zhang, Yan-Song; Liu, Wei-Hua

    2016-01-01

    To retrospectively evaluate short linear shadows connecting pulmonary segmental arteries to oblique fissures in thin-section CT images and determine their anatomical basis. CT scanning was performed on 108 patients and 11 lung specimens with no lung diseases around the oblique fissures or hilar. Two radiologists evaluated the imaging. The parameters included length, thickness of short linear shadows, pulmonary segmental artery variations, and traction interlobar fissures, etc. The short linear shadows were not related to sex, age, or smoking history. The lengths of the short linear shadows were generally within 10 mm. The thicknesses of the short linear shadows ranged from 1 to 2 mm. Of the patients, 26.9 % showed pulmonary segmental artery variations; 66.7 % of short linear shadows pulled oblique fissures. In three-dimensional images, the short linear shadows appeared as arc planes, with one side edge connected to the oblique fissure, one side edge connected to a pulmonary segmental artery. On the tissue slices, the short linear shadow exhibited a band structure composed of connective tissues, small blood vessels, and small lymphatic vessels. Short linear shadows are a type of normal intrapulmonary membranes and can maintain the integrity of the oblique fissures and hilar structure. (orig.)

  10. Comparative study of the characteristics of Ni films deposited on SiO2/Si(100) by oblique-angle sputtering and conventional sputtering

    International Nuclear Information System (INIS)

    Yu Mingpeng; Qiu Hong; Chen Xiaobai; Wu Ping; Tian Yue

    2008-01-01

    Ni films were deposited on SiO 2 /Si(100) substrates at 300 K and 573 K by oblique-angle sputtering and conventional sputtering. The films deposited at 300 K mainly have a [110] crystalline orientation in the growing direction whereas those deposited at 573 K grow with a [111] crystalline orientation in the growing direction. The film prepared only at 300 K by oblique-angle sputtering grows with a weakly preferential orientation along the incidence direction of the sputtered Ni atoms. All the films grow with thin columnar grains perpendicular to the substrate surface. The grain size of the films sputter-deposited obliquely is larger than that of the films sputter-deposited conventionally. The grain size of the Ni film does not change markedly with the deposition temperature. The film deposited at 573 K by oblique-angle sputtering has the highest saturation magnetization. For the conventional sputtering, the coercivity of the Ni film deposited at 573 K is larger than that of the film deposited at 300 K. However, for the oblique-angle sputtering, the coercivity of the Ni film is independent of the deposition temperature. All the Ni films exhibit an isotropic magnetization characteristic in the film plane

  11. Study of silicon-silicon nitride interface properties on planar (1 0 0), planar (1 1 1) and textured surfaces using deep-level transient spectroscopy

    International Nuclear Information System (INIS)

    Gong, Chun; Simoen, Eddy; Posthuma, Niels E; Van Kerschaver, Emmanuel; Poortmans, Jef; Mertens, Robert

    2010-01-01

    Deep-level transient spectroscopy (DLTS) has been applied to metal-insulator-semiconductor (MIS) capacitors fabricated on planar (1 0 0), planar (1 1 1) orientations and textured n-type silicon wafers. Low frequency direct plasma-enhanced chemical vapour deposition Si-SiN x interface properties with and without plasma NH 3 pre-treatment, with and without rapid thermal annealing (RTA) have been investigated. It is shown that three different kinds of defect states are identified at the Si-SiN x interface. For the planar (1 0 0) surface, samples with plasma NH 3 pre-treatment plus RTA show the lowest DLTS signals, which suggests the lowest overall interface states density. For planar (1 1 1) Si surfaces, plasma NH 3 pre-treatment and RTA yield a small improvement. With the textured surface, the RTA step improves the surface passivation quality further but no obvious impact is found with plasma NH 3 pre-treatment. Energy-dependent electron capture cross sections were also measured by small-pulse DLTS. The capture cross sections depend strongly on the energy level and decrease towards the conduction band edge.

  12. Comparison Of Planar And Wound Transformers For Flyback Forward And Half-Bridge Space Power Converters

    Science.gov (United States)

    Bjorklund, Thomas; Andreasen, John; Brosen, Finn; Matthiesen, Erik; Poulsen, Ole

    2011-10-01

    Planar technology has now entered the space domain. The big advantages of planar technology are; - Low profile - Excellent repeatability - Economical assembly - Mechanical integrity - Superior thermal characteristics This is why the general power industries increasingly are using planar magnetics in more and more applications, and therefore also why we see a rising demand for the usability of the planar technology among space application developers. The differences between wound and planar transformers have been mapped with a detailed look on the various parasitic component values, such as DC- and AC- resistance, Leakage Inductance and stray capacitance, and revealed the magnitude of the advantages of planar technology. This technical solution is proven in prototypes that have been built in different combination of PCB's and copper foil, with more or less interleaving of windings. Furthermore the transformers have been designed with several outputs stacked together with a fairly high number of primary turns, in order to have planar transformers similar to the wound types that are generally used for space applications.

  13. The normal tendon sheath of the second to fifth fingers as seen on oblique views

    International Nuclear Information System (INIS)

    Fischer, E.

    1984-01-01

    Oblique views of the fingers, using a low kilovolt technique, show a portion of the tendon sheaths which can be regarded as representative of the entire sheath. Because of the varying obliquity of each finger, this proportion differs in the fingers. With increasing age the projected portion of the sheath becomes smaller because it is covered by increasing bone formation in the insertion of the tendon sheat. Normal values have been obtained for adults according to their decades; from these, quite minor degrees of tendon sheat thickening can be determined. In camptodactyly of the fifth finger, which is not uncommon, the tendon sheat may be widened in the absence of a tenosynovitis. (orig.) [de

  14. L(2, 1-Labelings of Some Families of Oriented Planar Graphs

    Directory of Open Access Journals (Sweden)

    Sen Sagnik

    2014-02-01

    Full Text Available In this paper we determine, or give lower and upper bounds on, the 2-dipath and oriented L(2, 1-span of the family of planar graphs, planar graphs with girth 5, 11, 16, partial k-trees, outerplanar graphs and cacti.

  15. Development of planar SOE/SOFC reversible cell

    International Nuclear Information System (INIS)

    Kusunoki, A.; Matsubara, H.; Kikuoka, Y.; Yanagi, C.; Kugimiya, K.; Yoshino, M.; Tokura, M.; Watanabe, K.; Ueda, S.; Sumi, M.; Miyamoto, H.; Tokunaga, S.

    1993-01-01

    A new energy storage system using SOE/SOFC (solid oxide electrolysis-solid oxide fuel cells) reversible cells is presented, where a unit cell works as a fuel cell during a period of high electric power demand and alternately works as an electrolysis cell during a period of low power demand. A planar cell configuration is used which allows for a compact and low cost energy storage and load leveling system for power stations. Tests were performed to verify the reversibility of the planar cell, at 1000 deg C, with YSZ (Yttria stabilized zirconia) as the solid electrolyte, to improve the cell performance by reducing the overvoltage in electrolysis, and to obtain fundamental characteristics of a reversible cell. 3 figs

  16. On the tautomerism, planarity, and vibrations of phospholes

    International Nuclear Information System (INIS)

    Oziminski, Wojciech P.; Dobrowolski, Jan Cz.

    2005-01-01

    The PH and CH tautomers of mono-, di-, tri-, tetra-, and pentaphospholes were calculated at the B3LYP/aug-cc-pVTZ level. Except for 1,2,3-triphosphole and pentaphosphole, the most stable phosphole form is one of the CH tautomers. For 1,2-diphosphole, 1,3-diphosphole, and 1,2,4-triphosphole, the energy difference between the tautomers is large and only one tautomer may be observed. For other phospholes, especially tetraphosphole, two tautomers may coexist. Non-planarity of the five membered ring is present only in the σ 3 λ 3 -P atom containing molecules, i.e., PH type of tautomers, while in the CH type of tautomers the ring is planar. As earlier reported by Nyulaszi, the PH tautomers flatten, and the energy difference between PH phosphole and the planar transition state structure decreases, as the number of P atoms in the phosphole molecule is increased. Bond length changes were discussed in terms of configuration of the atoms attached to the bond, and the molecular frequency variations were examined according to the different surroundings of the appropriate vibrators

  17. Influence of fracture geometry on bone healing under locking plate fixations: A comparison between oblique and transverse tibial fractures.

    Science.gov (United States)

    Miramini, Saeed; Zhang, Lihai; Richardson, Martin; Mendis, Priyan; Ebeling, Peter R

    2016-10-01

    Mechano-regulation plays a crucial role in bone healing and involves complex cellular events. In this study, we investigate the change of mechanical microenvironment of stem cells within early fracture callus as a result of the change of fracture obliquity, gap size and fixation configuration using mechanical testing in conjunction with computational modelling. The research outcomes show that angle of obliquity (θ) has significant effects on interfragmentary movement (IFM) which influences mechanical microenvironment of the callus cells. Axial IFM at near cortex of fracture decreases with θ, while shear IFM significantly increases with θ. While a large θ can increase shear IFM by four-fold compared to transverse fracture, it also result in the tension-stress effect at near cortex of fracture callus. In addition, mechanical stimuli for cell differentiation within the callus are found to be strongly negatively correlated to angle of obliquity and gap size. It is also shown that a relatively flexible fixation could enhance callus formation in presence of a large gap but could lead to excessive callus strain and interstitial fluid flow when a small transverse fracture gap is present. In conclusion, there appears to be an optimal fixation configuration for a given angle of obliquity and gap size. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Asteroseismic Determination of Obliquities of the Exoplanet Systems Kepler-50 and Kepler-65

    DEFF Research Database (Denmark)

    Chaplin, W. J.; Sanchis-Ojeda, R.; Campante, T. L.

    2013-01-01

    Results on the obliquity of exoplanet host stars - the angle between the stellar spin axis and the planetary orbital axis - provide important diagnostic information for theories describing planetary formation. Here we present the first application of asteroseismology to the problem of stellar obl...

  19. Controllable fabrication of ultrafine oblique organic nanowire arrays and their application in energy harvesting

    Science.gov (United States)

    Zhang, Lu; Cheng, Li; Bai, Suo; Su, Chen; Chen, Xiaobo; Qin, Yong

    2015-01-01

    Ultrafine organic nanowire arrays (ONWAs) with a controlled direction were successfully fabricated by a novel one-step Faraday cage assisted plasma etching method. The mechanism of formation of nanowire arrays is proposed; the obliquity and aspect ratio can be accurately controlled from approximately 0° to 90° via adjusting the angle of the sample and the etching time, respectively. In addition, the ONWAs were further utilized to improve the output of the triboelectric nanogenerator (TENG). Compared with the output of TENG composed of vertical ONWAs, the open-circuit voltage, short-circuit current and inductive charges were improved by 73%, 150% and 98%, respectively. This research provides a convenient and practical method to fabricate ONWAs with various obliquities on different materials, which can be used for energy harvesting.

  20. Three sets of crystallographic sub-planar structures in quartz formed by tectonic deformation

    Science.gov (United States)

    Derez, Tine; Pennock, Gill; Drury, Martyn; Sintubin, Manuel

    2016-05-01

    In quartz, multiple sets of fine planar deformation microstructures that have specific crystallographic orientations parallel to planes with low Miller-Bravais indices are commonly considered as shock-induced planar deformation features (PDFs) diagnostic of shock metamorphism. Using polarized light microscopy, we demonstrate that up to three sets of tectonically induced sub-planar fine extinction bands (FEBs), sub-parallel to the basal, γ, ω, and π crystallographic planes, are common in vein quartz in low-grade tectonometamorphic settings. We conclude that the observation of multiple (2-3) sets of fine scale, closely spaced, crystallographically controlled, sub-planar microstructures is not sufficient to unambiguously distinguish PDFs from tectonic FEBs.

  1. Numerical Analysis Of Buckling Of Von Mises Planar Truss

    Directory of Open Access Journals (Sweden)

    Kalina Martin

    2015-12-01

    Full Text Available A computational algorithm of a discrete model of von Mises planar steel truss is presented. The structure deformation is evaluated by seeking the minimal potential energy. The critical force invented by mathematical solution was compared with solution by computer algorithm. Symmetric and asymmetric effects of initial shape of geometric imperfection of axis of struts are used in model. The shapes of buckling of von Mises planar truss of selected vertical displacement of top joint are shown.

  2. The Use of 3d City Models Form Oblique Images on Land Administration

    Science.gov (United States)

    Bakici, S.; Erkek, B.; Ayyildiz, E.; Özmüş, L.

    2017-11-01

    The article 718 of the civil law saying "The ownership on property includes the air above and terrain layers below to an extent providing benefit. The structures, plants and sources are included in the content of this ownership reserving the legal restrictions" and the cadastre law no. 3402 envisage 3D Cadastre. 3D data is required in order to perform 3D cadastre. To meet this requirement, oblique photogrammetry arises as the main data acquisition method. The data obtained by this method is used as base in 3D Cadastre and Land Administration activities. 3D cadastre required in the context of land administration activities in Turkey demands high resolution aerial oblique images to be used in services such as real estate value assessment & marketing in urban areas, urban planning, unlicensed construction monitoring & city administration and making location data (national address data etc.) intelligent.

  3. THE USE OF 3D CITY MODELS FORM OBLIQUE IMAGES ON LAND ADMINISTRATION

    Directory of Open Access Journals (Sweden)

    S. Bakici

    2017-11-01

    Full Text Available The article 718 of the civil law saying “The ownership on property includes the air above and terrain layers below to an extent providing benefit. The structures, plants and sources are included in the content of this ownership reserving the legal restrictions” and the cadastre law no. 3402 envisage 3D Cadastre. 3D data is required in order to perform 3D cadastre. To meet this requirement, oblique photogrammetry arises as the main data acquisition method. The data obtained by this method is used as base in 3D Cadastre and Land Administration activities. 3D cadastre required in the context of land administration activities in Turkey demands high resolution aerial oblique images to be used in services such as real estate value assessment & marketing in urban areas, urban planning, unlicensed construction monitoring & city administration and making location data (national address data etc. intelligent.

  4. Multi-projector auto-calibration and placement optimization for non-planar surfaces

    Science.gov (United States)

    Li, Dong; Xie, Jinghui; Zhao, Lu; Zhou, Lijing; Weng, Dongdong

    2015-10-01

    Non-planar projection has been widely applied in virtual reality and digital entertainment and exhibitions because of its flexible layout and immersive display effects. Compared with planar projection, a non-planar projection is more difficult to achieve because projector calibration and image distortion correction are difficult processes. This paper uses a cylindrical screen as an example to present a new method for automatically calibrating a multi-projector system in a non-planar environment without using 3D reconstruction. This method corrects the geometric calibration error caused by the screen's manufactured imperfections, such as an undulating surface or a slant in the vertical plane. In addition, based on actual projection demand, this paper presents the overall performance evaluation criteria for the multi-projector system. According to these criteria, we determined the optimal placement for the projectors. This method also extends to surfaces that can be parameterized, such as spheres, ellipsoids, and paraboloids, and demonstrates a broad applicability.

  5. Feasibility of Parylene Coating for Planar Electroporation Copper Electrodes

    Directory of Open Access Journals (Sweden)

    Vitalij NOVICKIJ

    2017-08-01

    Full Text Available This paper is focused on the feasibility study of parylene as a biocompatible coating for planar electroporation microelectrodes. The planar parallel and the circular interdigitated electrodes are applied in the analysis. The electrodes feature 100 μm width with a 300 μm gap between anode and cathode. The parylene coating thickness was varied in the 250 nm – 2 μm range. The resultant electric field distribution evaluation has been performed using the finite element method. The electrodes have been applied in electroporation experiments with Saprolegnia parasitica. For reference the additional experiments using conventional electroporation cuvette (1 mm gap have been performed. It has been determined that the parylene coating with hydrophobic properties has limited applicability for the passivation of the planar electroporation electrodes.DOI: http://dx.doi.org/10.5755/j01.ms.23.2.14953

  6. VERIFICATION OF 3D BUILDING MODELS USING MUTUAL INFORMATION IN AIRBORNE OBLIQUE IMAGES

    Directory of Open Access Journals (Sweden)

    A. P. Nyaruhuma

    2012-07-01

    Full Text Available This paper describes a method for automatic verification of 3D building models using airborne oblique images. The problem being tackled is identifying buildings that are demolished or changed since the models were constructed or identifying wrong models using the images. The models verified are of CityGML LOD2 or higher since their edges are expected to coincide with actual building edges. The verification approach is based on information theory. Corresponding variables between building models and oblique images are used for deriving mutual information for individual edges, faces or whole buildings, and combined for all perspective images available for the building. The wireframe model edges are projected to images and verified using low level image features – the image pixel gradient directions. A building part is only checked against images in which it may be visible. The method has been tested with models constructed using laser points against Pictometry images that are available for most cities of Europe and may be publically viewed in the so called Birds Eye view of the Microsoft Bing Maps. Results are that nearly all buildings are correctly categorised as existing or demolished. Because we now concentrate only on roofs we also used the method to test and compare results from nadir images. This comparison made clear that especially height errors in models can be more reliably detected in oblique images because of the tilted view. Besides overall building verification, results per individual edges can be used for improving the 3D building models.

  7. Surface Enhanced Raman Scattering Substrates Made by Oblique Angle Deposition: Methods and Applications

    Directory of Open Access Journals (Sweden)

    Hin On Chu

    2017-02-01

    Full Text Available Surface Enhanced Raman Spectroscopy presents a rapid, non-destructive method to identify chemical and biological samples with up to single molecule sensitivity. Since its discovery in 1974, the technique has become an intense field of interdisciplinary research, typically generating >2000 publications per year since 2011. The technique relies on the localised surface plasmon resonance phenomenon, where incident light can couple with plasmons at the interface that result in the generation of an intense electric field. This field can propagate from the surface from the metal-dielectric interface, so molecules within proximity will experience more intense Raman scattering. Localised surface plasmon resonance wavelength is determined by a number of factors, such as size, geometry and material. Due to the requirements of the surface optical response, Ag and Au are typical metals used for surface enhanced Raman applications. These metals then need to have nano features that improve the localised surface plasmon resonance, several variants of these substrates exist; surfaces can range from nanoparticles in a suspension, electrochemically roughened electrodes to metal nanostructures on a substrate. The latter will be the focus of this review, particularly reviewing substrates made by oblique angle deposition. Oblique angle deposition is the technique of growing thin films so that the material flux is not normal to the surface. Films grown in this fashion will possess nanostructures, due to the atomic self-shadowing effect, that are dependent mainly on the deposition angle. Recent developments, applications and highlights of surface enhanced Raman scattering substrates made by oblique angle deposition will be reviewed.

  8. Propagation of ULF waves through the ionosphere: Inductive effect for oblique magnetic fields

    Directory of Open Access Journals (Sweden)

    M. D. Sciffer

    2004-04-01

    Full Text Available Solutions for ultra-low frequency (ULF wave fields in the frequency range 1–100mHz that interact with the Earth's ionosphere in the presence of oblique background magnetic fields are described. Analytic expressions for the electric and magnetic wave fields in the magnetosphere, ionosphere and atmosphere are derived within the context of an inductive ionosphere. The inductive shielding effect (ISE arises from the generation of an "inductive" rotational current by the induced part of the divergent electric field in the ionosphere which reduces the wave amplitude detected on the ground. The inductive response of the ionosphere is described by Faraday's law and the ISE depends on the horizontal scale size of the ULF disturbance, its frequency and the ionosphere conductivities. The ISE for ULF waves in a vertical background magnetic field is limited in application to high latitudes. In this paper we examine the ISE within the context of oblique background magnetic fields, extending studies of an inductive ionosphere and the associated shielding of ULF waves to lower latitudes. It is found that the dip angle of the background magnetic field has a significant effect on signals detected at the ground. For incident shear Alfvén mode waves and oblique background magnetic fields, the horizontal component of the field-aligned current contributes to the signal detected at the ground. At low latitudes, the ISE is larger at smaller conductivity values compared with high latitudes.

    Key words. Ionosphere (ionosphere-magnetosphere interactions; electric fields and currents; wave propagation

  9. Planar-Processed Polymer Transistors.

    Science.gov (United States)

    Xu, Yong; Sun, Huabin; Shin, Eul-Yong; Lin, Yen-Fu; Li, Wenwu; Noh, Yong-Young

    2016-10-01

    Planar-processed polymer transistors are proposed where the effective charge injection and the split unipolar charge transport are all on the top surface of the polymer film, showing ideal device characteristics with unparalleled performance. This technique provides a great solution to the problem of fabrication limitations, the ambiguous operating principle, and the performance improvements in practical applications of conjugated-polymer transistors. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Tests of planar permanent magnet multipole focusing elements

    International Nuclear Information System (INIS)

    Cobb, J.; Tatchyn, R.

    1993-08-01

    In recent work, planar configurations of permanent magnets were proposed as substitutes for conventional current-driven iron quadrupoles in applications limited by small aperture sizes and featuring small beam occupation diameters. Important examples include the configuring of focusing lattices in small-gap insertion devices, and the implementation of compact mini-beta sections on linear or circular machines. In subsequent analysis, this approach was extended to sextupoles and higher-order multipoles. In this paper we report on initial measurements conducted at the Stanford Linear Accelerator Center on recently fabricated planar permanent magnet quadrupoles and sextupoles configured out of SmCo and NdFe/B

  11. Two characteristics of planar intertwined basins of attraction

    International Nuclear Information System (INIS)

    Ding Changming

    2012-01-01

    Highlights: ► A new mathematical definition of intertwined basins of attraction is proposed. ► Basins are intertwined iff a limit set of stable manifold contains at least two points. ► Basins are intertwined iff the closure of stable manifold is not arc-connected. ► The intertwining property is preserved by topologically equivalent dynamical systems. - Abstract: In this paper, we investigate the intertwined basins of attraction for planar dynamical systems. We prove that the intertwining property is preserved by topologically equivalent systems. Two necessary and sufficient conditions for a planar system having intertwined basins are given.

  12. Oblique impact: a process for providing meteorite samples of other planets

    International Nuclear Information System (INIS)

    Okeefe, J.D.; Ahrens, T.J.

    1986-03-01

    Cratering flow calculations for a series of oblique to normal impacts of silicate projectiles onto a silicate halfspace were carried out to determine whether the gas produced upon shock vaporizing both projectile and planetary material could entrain and accelerate surface rocks and thus provide a mechanism for propelling SNC meteorites from the Martian surface. The difficult constraints that the impact origin hypothesis for SNC meteorites has to satisfy are that these meteorites are lightly to moderately shocked and yet were accelerated to speeds in excess of the Martian escape velocity. Two dimensional finite difference calculations demonstrate that at highly probable impact velocities, vapor plume jets are produced at oblique impact angles of 25 deg to 60 deg and have speeds as great as 20 km/sec. These plumes flow nearly parallel to the planetary surface. It is shown that upon impact of projectiles having radii of 0.1 to 1 km, the resulting vapor jets have densities of 0.1 to 1 g/cu.cm. These jets can entrain Martian surface rocks and accelerate them to velocities 5 km/sec. It is suggested that this mechanism launches SNC meteorites to Earth

  13. How sedimentation affects rift segment interaction during oblique extension: a 4D analogue modelling study

    Science.gov (United States)

    Zwaan, Frank; Schreurs, Guido; Adam, Jürgen

    2017-04-01

    During the early stages of rifting, rift segments may form along non-continuous and/or offset pre-existing weaknesses. It is important to understand how these initial rift segments interact and connect to form a continuous rift system. Previous modelling of rift interaction structures has shown the dominant influence of oblique extension, promoting rift segment linkage (e.g. Zwaan et al., 2016) and eventual continent break-up (Brune et al., 2012). However, these studies did not incorporate sedimentation, which can have important implications for rift evolution (e.g. Bialas and Buck, 2009). Here we present a series of analogue model experiments investigating the influence of sedimentation on rift interaction structures under oblique extension conditions. Our set-up involves a base of compressed foam and plexiglass that forces distributed extension in the overlying analogue materials when the model sidewalls move apart. A sand layer simulates the brittle upper crust and a viscous sand/silicone mixture the ductile lower crust. One of the underlying base plates can move laterally allowing oblique extension. Right-stepping offset and disconnected lines of silicone (seeds) on top of the basal viscous serve as inherited structures since the strong sand cover is locally thinner. We apply syn-rift sediments by filling in the developing rift and transfer zone basins with sand at fixed time steps. Models are run either with sedimentation or without to allow comparison. The first results suggest that the gross structures are similar with or without sedimentation. As seen by Zwaan et al. (2016), dextral oblique extension promotes rift linkage because rift propagation aligns itself perpendicular to the extension direction. This causes the rift segments to grow towards each other and to establish a continuous rift structure. However, the structures within the rift segments show quite different behaviour when sedimentation is applied. The extra sediment loading in the rift basin

  14. The planar cubic Cayley graphs

    CERN Document Server

    Georgakopoulos, Agelos

    2018-01-01

    The author obtains a complete description of the planar cubic Cayley graphs, providing an explicit presentation and embedding for each of them. This turns out to be a rich class, comprising several infinite families. He obtains counterexamples to conjectures of Mohar, Bonnington and Watkins. The author's analysis makes the involved graphs accessible to computation, corroborating a conjecture of Droms.

  15. Casimir stress inside planar materials

    Science.gov (United States)

    Griniasty, Itay; Leonhardt, Ulf

    2017-09-01

    The Casimir force between macroscopic bodies is well understood, but not the Casimir force inside bodies. Guided by a physically intuitive picture, we develop the macroscopic theory of the renormalized Casimir stress inside planar materials (where the electromagnetic properties vary in one direction). Our theory may be applied in predicting how inhomogeneous fluids respond to Casimir forces.

  16. Approximation by planar elastic curves

    DEFF Research Database (Denmark)

    Brander, David; Gravesen, Jens; Nørbjerg, Toke Bjerge

    2016-01-01

    We give an algorithm for approximating a given plane curve segment by a planar elastic curve. The method depends on an analytic representation of the space of elastic curve segments, together with a geometric method for obtaining a good initial guess for the approximating curve. A gradient......-driven optimization is then used to find the approximating elastic curve....

  17. Characteristics of heat transfer and fluid flow in a channel with single-row plates array oblique to flow direction for photovoltaic/thermal system

    International Nuclear Information System (INIS)

    Ali, Ahmed Hamza H.; Ahmed, Mahmoud; Youssef, M.S.

    2010-01-01

    This study has been carried out to investigate the characteristics of convective heat transfer and fluid flow for a single row of oblique plates array to the flow direction inside a channel. The flow inside the channel is laminar and the plates array have spanwise distance between the plates and heated by radiation. This configuration has been designed to be used for Photovoltaic/Thermal system (PV/T) applications. The theoretical results are validated with measured values, and a good agreement prevailed. The results show that an increase in the plate oblique angle (γ) in the range from 0 to 15 degrees, leads to an increase in the Nusselt number (Nu) up to a maximum value and then decreases. The oblique angle at the maximum value of Nu depends on the flow Reynolds Number (Re), and (l w /l pl ), where (l w /l pl ) is defined as the ratio of the plates' spacing at zero oblique angle to the plate length. Furthermore, increasing (l w /l pl ) results in a significant increase in the heat transfer coefficient depending on the values of Re, and plate oblique angle (γ). In addition, increasing (γ) from 0 to 15 degrees results in a decrease in the friction factor up to a certain value, after which the friction value approaches a constant value depending on Re value and (l w /l pl ). It was found that for any value of the plate oblique angle (γ), the friction factor decreases with the increase of the values of (l w /l pl ) and Re, respectively.

  18. Fundamental losses in planar Bragg waveguides

    NARCIS (Netherlands)

    Vinogradov, A. V.; Mitrofanov, A. N.; Popov, A. V.; Fedin, M. A.

    2007-01-01

    This paper considers a planar Bragg waveguide. The guided modes and their dissipation due to the fundamental absorption are described. In the interacting-wave approximation, an analytical relation between the characteristics of the modes and parameters of the Bragg-waveguide geometry was

  19. Planar Dirac diffusion

    International Nuclear Information System (INIS)

    Leo, Stefano de; Rotelli, Pietro

    2009-01-01

    We present the results of the planar diffusion of a Dirac particle by step and barrier potentials, when the incoming wave impinges at an arbitrary angle with the potential. Except for right-angle incidence this process is characterized by the appearance of spin flip terms. For the step potential, spin flip occurs for both transmitted and reflected waves. However, we find no spin flip in the transmitted barrier result. This is surprising because the barrier result may be derived directly from a two-step calculation. We demonstrate that the spin flip cancellation indeed occurs for each ''particle'' (wave packet) contribution. (orig.)

  20. A constant gradient planar accelerating structure for linac use

    International Nuclear Information System (INIS)

    Kang, Y.W.; Matthews, P.J.; Kustom, R.L.

    1995-01-01

    Planar accelerating millimeter-wave structures have been studied during the last few years at Argonne National Laboratory in collaboration with Technical University of Berlin. The cavity structures are intended to be manufactured by using x-ray lithography microfabrication technology. A complete structure consists of two identical planar half structures put together face-to-face. Since microfabrication technology can make a since-depth indentation on a planar substrate, realizing the constant impedance structure was possible but a constant gradient structure was difficult; changing the group velocity along the structure while maintaining the gap and the depth of the indentation constant was difficult. A constant gradient structure has been devised by introducing a cut between the adjacent cavity cells along the beam axis of each half structure. The width of the cut is varied along the longitudinal axis of the structure to have proper coupling between the cells. The result of the computer simulation on such structures is shown